Complementary role of cardiac CT in the assessment of aortic valve replacement dysfunction
Moss, Alastair J; Dweck, Marc R; Dreisbach, John G; Williams, Michelle C; Mak, Sze Mun; Cartlidge, Timothy; Nicol, Edward D; Morgan-Hughes, Gareth J
2016-01-01
Aortic valve replacement is the second most common cardiothoracic procedure in the UK. With an ageing population, there are an increasing number of patients with prosthetic valves that require follow-up. Imaging of prosthetic valves is challenging with conventional echocardiographic techniques making early detection of valve dysfunction or complications difficult. CT has recently emerged as a complementary approach offering excellent spatial resolution and the ability to identify a range of aortic valve replacement complications including structural valve dysfunction, thrombus development, pannus formation and prosthetic valve infective endocarditis. This review discusses each and how CT might be incorporated into a multimodal cardiovascular imaging pathway for the assessment of aortic valve replacements and in guiding clinical management. PMID:27843568
Pannus-related prosthetic valve dysfunction. Case report
MOLDOVAN, MARIA-SÎNZIANA; BEDELEANU, DANIELA; KOVACS, EMESE; CIUMĂRNEAN, LORENA; MOLNAR, ADRIAN
2016-01-01
Pannus-related prosthetic valve dysfunction, a complication of mechanical prosthetic valve replacement, is rare, with a slowly progressive evolution, but it can be acute, severe, requiring surgical reintervention. We present the case of a patient with a mechanical single disc aortic prosthesis, with moderate prosthesis-patient mismatch, minor pannus found on previous ultrasound examinations, who presented to our service with angina pain with a duration of 1 hour, subsequently interpreted as non-ST segment elevation myocardial infarction (NSTEMI) syndrome. Coronarography showed normal epicardial coronary arteries, an ample movement of the prosthetic disc, without evidence of coronary thromboembolism, and Gated Single-Photon Emission Computerized Tomography (SPECT) with Technetium (Tc)-99m detected no perfusion defects. Transthoracic echocardiography (TTE) evidenced a dysfunctional prosthesis due to a subvalvular mass; transesophageal echocardiography (TOE) showed the interference of this mass, with a pannus appearance, with the closure of the prosthetic disc. Under conditions of repeated angina episodes, under anticoagulant treatment, surgery was performed, with the intraoperative confirmation of pannus and its removal. Postoperative evolution was favorable. This case reflects the diagnostic and therapeutic management problems of pannus-related prosthetic valve dysfunction. PMID:27004041
Pannus-related prosthetic valve dysfunction. Case report.
Moldovan, Maria-Sînziana; Bedeleanu, Daniela; Kovacs, Emese; Ciumărnean, Lorena; Molnar, Adrian
2016-01-01
Pannus-related prosthetic valve dysfunction, a complication of mechanical prosthetic valve replacement, is rare, with a slowly progressive evolution, but it can be acute, severe, requiring surgical reintervention. We present the case of a patient with a mechanical single disc aortic prosthesis, with moderate prosthesis-patient mismatch, minor pannus found on previous ultrasound examinations, who presented to our service with angina pain with a duration of 1 hour, subsequently interpreted as non-ST segment elevation myocardial infarction (NSTEMI) syndrome. Coronarography showed normal epicardial coronary arteries, an ample movement of the prosthetic disc, without evidence of coronary thromboembolism, and Gated Single-Photon Emission Computerized Tomography (SPECT) with Technetium (Tc)-99m detected no perfusion defects. Transthoracic echocardiography (TTE) evidenced a dysfunctional prosthesis due to a subvalvular mass; transesophageal echocardiography (TOE) showed the interference of this mass, with a pannus appearance, with the closure of the prosthetic disc. Under conditions of repeated angina episodes, under anticoagulant treatment, surgery was performed, with the intraoperative confirmation of pannus and its removal. Postoperative evolution was favorable. This case reflects the diagnostic and therapeutic management problems of pannus-related prosthetic valve dysfunction.
2012-01-01
Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function. The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement. A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve. Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function. PMID:22747790
Darwazah, Ahmad K
2012-06-29
Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function.The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement.A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve.Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function.
Hurwitz, Seth Eric; Waxman, Daniel; Hecht, Susan
2009-09-01
Pannus formation and valve thrombus can cause prosthetic valve failure. The authors report the case of a 50-year-old woman who presented to the emergency room with decompensated heart failure secondary to mechanical valve dysfunction. On two-dimensional and transesophageal echocardiography, the patient had severe aortic stenosis and regurgitation. A thrombus seen on the valve was felt to be the etiology of her prosthetic valve failure. She underwent emergent cardiac surgery for aortic valve replacement. Pathology revealed that although a small thrombus was present, extensive pannus was the underlying mechanism of valve dysfunction. Differentiation between pannus and thrombus may have important clinical implications, but this case illustrates that distinguishing between these entities by echocardiographic and clinical criteria may not be possible.
Mitral valve-sparing procedures and prosthetic heart valve failure: A case report
Khan, Nasir A; Butany, Jagdish; Leong, Shaun W; Rao, Vivek; Cusimano, Robert J; Ross, Heather J
2009-01-01
Prosthetic heart valve dysfunction due to thrombus or pannus formation can be a life-threatening complication. The present report describes a 47-year-old woman who developed valvular cardiomyopathy after chorda-sparing mitral valve replacement, and subsequently underwent heart transplantation for progressive heart failure. The explanted mitral valve prosthesis showed significant thrombus and pannus leading to reduced leaflet mobility and valvular stenosis. The present report illustrates the role of the subvalvular apparatus and pannus in prosthesis dysfunction. PMID:19279993
Ozkan, Mehmet; Astarcioglu, Mehmet Ali; Karakoyun, Suleyman; Balkanay, Mehmet
2012-02-01
Obstruction to a prosthetic cardiac valve is a well-recognized complication of cardiac valve replacement. Malfunction of the mobile component of a prosthetic valve to open or close correctly may occur in consequence of intrinsic or extrinsic causes (thrombus, vegetation, entrapment of left ventricular myocardium, suture entanglement, and pannus formation) that may result prosthetic valve stenosis and/or insufficiency. In the case we report a 48-year-old female with valve dysfunction occurred early after surgery, as one valve leaflet was only able to partially open due to suture entrapment. © 2011, Wiley Periodicals, Inc.
Marcinkiewicz, Anna; Kośmider, Anna; Walczak, Andrzej; Zwoliński, Radosław; Jaszewski, Ryszard
2015-01-01
Introduction Approximately 60 000 prosthetic valves are implanted annually in the USA. The risk of prosthesis dysfunction ranges from 0.1% to 4% per year. Prosthesis valve dysfunction is usually caused by a thrombus obstructing the prosthetic discs. However, 10% of prosthetic valves are dysfunctional due to pannus formation, and 12% of prostheses are damaged by both fibrinous and thrombotic components. The authors present two patients with dysfunctional aortic prostheses who were referred for cardiac surgery. Different surgical solutions were used in the treatment of each case. Case study 1 The first patient was a 71-year-old woman whose medical history included arterial hypertension, stable coronary artery disease, diabetes mellitus, chronic obstructive pulmonary disease (COPD), and hypercholesterolemia; she had previously undergone left-sided mastectomy and radiotherapy. The patient was admitted to the Cardiac Surgery Department due to aortic prosthesis dysfunction. Transthoracic echocardiography revealed complete obstruction of one disc and a severe reduction in the mobility of the second. The mean transvalvular gradient was very high. During the operation, pannus covering the discs’ surface was found. A biological aortic prosthesis was reimplanted without complications. Case study 2 The second patient was an 87-year-old woman with arterial hypertension, persistent atrial fibrillation, and COPD, whose past medical history included gastric ulcer disease and ischemic stroke. As in the case of the first patient, she was admitted due to valvular prosthesis dysfunction. Preoperative transthoracic echocardiography revealed an obstruction of the posterior prosthetic disc and significant aortic regurgitation. Transesophageal echocardiography and fluoroscopy confirmed the prosthetic dysfunction. During the operation, a thrombus growing around a minor pannus was found. The thrombus and pannus were removed, and normal functionality of the prosthetic valve was restored. Conclusions Precise and modern diagnostic methods facilitated selection of the treatment method. However, the intraoperative view also seems to be crucial in individualizing the surgical approach. PMID:26702274
Ostrowski, Stanisław; Marcinkiewicz, Anna; Kośmider, Anna; Walczak, Andrzej; Zwoliński, Radosław; Jaszewski, Ryszard
2015-09-01
Approximately 60 000 prosthetic valves are implanted annually in the USA. The risk of prosthesis dysfunction ranges from 0.1% to 4% per year. Prosthesis valve dysfunction is usually caused by a thrombus obstructing the prosthetic discs. However, 10% of prosthetic valves are dysfunctional due to pannus formation, and 12% of prostheses are damaged by both fibrinous and thrombotic components. The authors present two patients with dysfunctional aortic prostheses who were referred for cardiac surgery. Different surgical solutions were used in the treatment of each case. The first patient was a 71-year-old woman whose medical history included arterial hypertension, stable coronary artery disease, diabetes mellitus, chronic obstructive pulmonary disease (COPD), and hypercholesterolemia; she had previously undergone left-sided mastectomy and radiotherapy. The patient was admitted to the Cardiac Surgery Department due to aortic prosthesis dysfunction. Transthoracic echocardiography revealed complete obstruction of one disc and a severe reduction in the mobility of the second. The mean transvalvular gradient was very high. During the operation, pannus covering the discs' surface was found. A biological aortic prosthesis was reimplanted without complications. The second patient was an 87-year-old woman with arterial hypertension, persistent atrial fibrillation, and COPD, whose past medical history included gastric ulcer disease and ischemic stroke. As in the case of the first patient, she was admitted due to valvular prosthesis dysfunction. Preoperative transthoracic echocardiography revealed an obstruction of the posterior prosthetic disc and significant aortic regurgitation. Transesophageal echocardiography and fluoroscopy confirmed the prosthetic dysfunction. During the operation, a thrombus growing around a minor pannus was found. The thrombus and pannus were removed, and normal functionality of the prosthetic valve was restored. Precise and modern diagnostic methods facilitated selection of the treatment method. However, the intraoperative view also seems to be crucial in individualizing the surgical approach.
Oh, Se Jin; Park, Samina; Kim, Jun Sung; Kim, Kyung-Hwan; Kim, Ki Bong; Ahn, Hyuk
2013-07-01
The authors' clinical experience is presented of non-structural valvular dysfunction of the prosthetic aortic valve caused by pannus ingrowth during the late postoperative period after previous heart valve surgery. Between January 1999 and April 2012, at the authors' institution, a total of 33 patients underwent reoperation for increased mean pressure gradient of the prosthetic aortic valve. All patients were shown to have pannus ingrowth. The mean interval from the previous operation was 16.7 +/- 4.3 years, and the most common etiology for the previous aortic valve replacement (AVR) was rheumatic valve disease. The mean effective orifice area index (EOAI) of the previous prosthetic valve was 0.97 +/- 0.11 cm2/m2, and the mean pressure gradient on the aortic prosthesis before reoperation was 39.1 +/- 10.7 mmHg. Two patients (6.1%) died in-hospital, and late death occurred in six patients (18.2%). At the first operation, 30 patients underwent mitral or tricuspid valve surgery as a concomitant procedure. Among these operations, mitral valve replacement (MVR) was combined in 24 of all 26 patients with rheumatic valve disease. Four patients underwent pannus removal only while the prosthetic aortic valve was left in place. The mean EOAI after reoperation was significantly increased to 1.16 +/- 0.16 cm2/m2 (p < 0.001), and the mean pressure gradient was decreased to 11.9 +/- 1.9 mmHg (p < 0.001). Non-structural valvular dysfunction caused by pannus ingrowth was shown in patients with a small EOAI of the prosthetic aortic valve and combined MVR for rheumatic disease. As reoperation for pannus overgrowth showed good clinical outcomes, an aggressive resection of pannus and repeated AVR should be considered in symptomatic patients to avoid the complications of other cardiac diseases.
Yuasa, Toshinori; Takasaki, Kunitsugu; Mizukami, Naoko; Ueya, Nami; Kubota, Kayoko; Horizoe, Yoshihisa; Chaen, Hideto; Kuwahara, Eiji; Kisanuki, Akira; Hamasaki, Shuichi
2013-09-01
A 39-year-old male who had undergone tricuspid valve replacement for severe tricuspid regurgitation was admitted with palpitation and general edema. Two-dimensional (2D) echocardiography showed tricuspid prosthetic valve dysfunction. Additional three-dimensional (3D) transthoracic and transesophageal echocardiography (TEE) could clearly demonstrate the disabilities of the mechanical tricuspid valve. Particularly, 3D TEE demonstrated a mass located on the right ventricular side of the tricuspid prosthesis, which may have caused the stuck disk. This observation was confirmed by intra-operative findings.
Luis, Sushil Allen; Blauwet, Lori A; Samardhi, Himabindu; West, Cathy; Mehta, Ramila A; Luis, Chris R; Scalia, Gregory M; Miller, Fletcher A; Burstow, Darryl J
2017-10-15
This study aimed to investigate the utility of transthoracic echocardiographic (TTE) Doppler-derived parameters in detection of mitral prosthetic dysfunction and to define optimal cut-off values for identification of such dysfunction by valve type. In total, 971 TTE studies (647 mechanical prostheses; 324 bioprostheses) were compared with transesophageal echocardiography for evaluation of mitral prosthesis function. Among all prostheses, mitral valve prosthesis (MVP) ratio (ratio of time velocity integral of MVP to that of left ventricular outflow tract; odds ratio [OR] 10.34, 95% confidence interval [95% CI] 6.43 to 16.61, p<0.001), E velocity (OR 3.23, 95% CI 1.61 to 6.47, p<0.001), and mean gradient (OR 1.13, 95% CI 1.02 to 1.25, p=0.02) provided good discrimination of clinically normal and clinically abnormal prostheses. Optimal cut-off values by receiver operating characteristic analysis for differentiating clinically normal and abnormal prostheses varied by prosthesis type. Combining MVP ratio and E velocity improved specificity (92%) and positive predictive value (65%) compared with either parameter alone, with minimal decline in negative predictive value (92%). Pressure halftime (OR 0.99, 95% CI 0.98 to 1.00, p=0.04) did not differentiate between clinically normal and clinically abnormal prostheses but was useful in discriminating obstructed from normal and regurgitant prostheses. In conclusion, cut-off values for TTE-derived Doppler parameters of MVP function were specific to prosthesis type and carried high sensitivity and specificity for identifying prosthetic valve dysfunction. MVP ratio was the best predictor of prosthetic dysfunction and, combined with E velocity, provided a useful parameter for determining likelihood of dysfunction and need for further assessment. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.
Koo, Hyun Jung; Ha, Hojin; Kang, Joon-Won; Kim, Jeong A; Song, Jae-Kwan; Kim, Hwa Jung; Lim, Tae-Hwan; Yang, Dong Hyun
2018-02-19
Although pannus is an important cause of prosthetic valve dysfunction, the minimum pannus size that can induce hemodynamic dysfunction has not yet been determined. This study investigated the correlation between the limitation of motion (LOM) of the prosthetic valve and pannus extent and determined the pannus extent that could induce severe aortic stenosis. This study included 49 patients who underwent mechanical aortic valve replacement (AVR) and showed pannus on cardiac computed tomography (CT). Pannus width, ratio of pannus width to valve diameter, pannus area, effective orifice area, encroachment ratio by pannus, pannus involvement angle and percent LOM of mechanical valves were evaluated on CT. Transvalvular peak velocity (TPV) and transvalvular pressure gradient (TPG) were measured by transesophageal echocardiography to determine the degree of aortic stenosis. The relationship between percent LOM of the prosthetic valve and pannus extent and the cut-off of pannus extent required to induce severe aortic stenosis were evaluated. The mean interval between AVR and pannus formation was 11 years and was longer in patients with than without severe aortic stenosis (14.0 vs. 7.3 years). On CT, the percent LOM of the prosthetic valve was significantly associated with the extent of pannus only in patients with pannus involvement angle > 180° (r = 0.55-0.68, P < 0.01). Pannus width, effective orifice area, and encroachment ratio were significantly associated with increased TPV and TPG (r = 0.51-0.62, P < 0.01). Pannus width > 3.5 mm, pannus width/valve inner diameter > 0.15, and encroachment ratio > 0.14 were significantly associated with severe aortic stenosis (TPV > 4 m/s; mean TPG ≥ 35 mmHg), with c-indices of 0.74-079 (P < 0.005). CT-derived pannus extent parameters are good indicators of significant hemodynamic changes with increased TPV and mean TPG.
Tsai, I-Chen; Lin, Yung-Kai; Chang, Yen; Fu, Yun-Ching; Wang, Chung-Chi; Hsieh, Shih-Rong; Wei, Hao-Ji; Tsai, Hung-Wen; Jan, Sheng-Ling; Wang, Kuo-Yang; Chen, Min-Chi; Chen, Clayton Chi-Chang
2009-04-01
The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Björk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral replacements and one Amplatzer ductal occluder occlusion of a mitral paravalvular leak. The concordance of MDCT for diagnosing and localizing prosthetic valve disorders and the surgical findings was 100%. Except for images impaired by severe beam-hardening artifacts, MDCT provides excellent delineation of prosthetic valve disorders.
Echocardiographic Assessment of Heart Valve Prostheses
Sordelli, Chiara; Severino, Sergio; Ascione, Luigi; Coppolino, Pasquale; Caso, Pio
2014-01-01
Patients submitted to valve replacement with mechanical or biological prosthesis, may present symptoms related either to valvular malfunction or ventricular dysfunction from other causes. Because a clinical examination is not sufficient to evaluate a prosthetic valve, several diagnostic methods have been proposed to assess the functional status of a prosthetic valve. This review provides an overview of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. Compared to native valves, echocardiographic evaluation of prosthetic valves is certainly more complex, both for the examination and the interpretation. Echocardiography also allows discriminating between intra- and/or peri-prosthetic regurgitation, present in the majority of mechanical valves. Transthoracic echocardiography (TTE) requires different angles of the probe with unconventional views. Transesophageal echocardiography (TEE) is the method of choice in presence of technical difficulties. Three-dimensional (3D)-TEE seems to be superior to 2D-TEE, especially in the assessment of paravalvular leak regurgitation (PVL) that it provides improved localization and analysis of the PVL size and shape. PMID:28465917
Red flag in the emergency department: fracture and primary failure of a prosthetic valve.
Ozsarac, Murat; Karcioglu, Ozgur; Ayrik, Cuneyt; Bozkurt, Seyran; Turkcuer, Ibrahim; Gumrukcu, Serhat
2005-07-01
This case report concerns a patient with fracture and primary dysfunction of a prosthetic valve. A 40-year-old man presented to the Emergency Department with a chief complaint of breakthrough pleuritic back pain and shortness of breath. Past surgical history was significant only for an aortic valve replacement and mitral valve replacement performed 16 years prior. The transthoracic echocardiography raised suspicion of prosthesis malposition. The patient was taken to the operating room by cardiothoracic surgeons for valve replacement. Operative findings revealed that a prosthetic valve leaflet in the mitral position had broken off. Primary prosthetic valve failure should not be overlooked in the differential diagnosis of patients with valve replacement and a rapidly deteriorating clinical course. Emergency echocardiography is a guide to convenient diagnosis and management. Early surgical consultation and early reparative surgery might prevent unnecessary morbidity and mortality.
Evaluation of p53 Polymorphism in Patients with Pannus-Derived Prosthetic Dysfunction.
Gursoy, Mustafa Ozan; Karakoyun, Suleyman; Kalcik, Macit; Yesin, Mahmut; Gunduz, Sabahattin; Astarcioğlu, Mehmet Ali; Oğuz, Ali Emrah; Ozkan, Mehmet
2015-09-01
Prosthetic valve dysfunction (PVD) due to pannus formation is considered to occur due to a bioreaction to prosthetic material. The p53 gene plays a critical role in apoptosis and cell proliferation. p53 Arg72Pro polymorphism has been found to be associated with coronary stent restenosis, but has not yet been studied in prosthetic heart valve dysfunction. The study aim was to evaluate the association between pannus-derived PVD and p53 G72C(Arg72Pro) polymorphism. This single-center, prospective study included 25 patients (20 females, five males; mean age 45.6 +/- 12.5 years; group 1) who underwent redo valve surgery due to PVD, and 49 age- and gender-matched control patients (44 females, five males; mean age 47.3 +/- 12.2 years; group 2) with normofunctional prostheses. The prostheses were examined using transthoracic and transesophageal echocardiography. Analyses of p53 G72C(Arg72Pro) polymorphism were performed using Roche LightCyler 2.0 Real-time polymerase chain reaction. The most common location of replaced valves was the mitral position in both groups (88% and 89.8%, respectively). In group 1, normal alleles (GG) were observed in 12 patients (48%), while one patient (4%) showed a homozygous mutation (GC) and 12 patients (48%) showed a heterozygous mutation (CC). In group 2, 21 patients (42.9%) had normal alleles (GG), while four (8.2%) had a homozygous mutation (CC) and 24 (48.9%) had a heterozygous mutation (GC). No significant difference was observed between the groups with regards to p53 Arg72Pro polymorphism (p = 0.769). In patients with prosthetic valves, the underlying mechanism behind pannus formation is unrelated to p53 Arg72Pro polymorphism.
Karakoyun, Süleyman; Ozan Gürsoy, Mustafa; Yesin, Mahmut; Kalçık, Macit; Astarcıoğlu, Mehmet Ali; Gündüz, Sabahattin; Emrah Oğuz, Ali; Çoban Kökten, Şermin; Nimet Karadayı, Ayşe; Tuncer, Altuğ; Köksal, Cengiz; Gökdeniz, Tayyar; Özkan, Mehmet
2016-01-01
Prosthetic valve dysfunction due to pannus formation is a rare but serious complication. Currently, limited data are available concerning the pathogenesis and immunohistochemical properties of pannus. The study aim was to investigate the morphological, histopathological and immunohistochemical characteristics of pannus formation in patients with prosthetic valve dysfunction. A total of 35 patients (10 males, 25 females; mean age 44 ± 16 years) who had undergone re-do valve surgery due to prosthetic valve obstruction was enrolled in the study. Immunohistochemical studies were aimed at evaluating the expression of alphasmooth muscle actin (α-SMA) and desmin in myofibroblasts and smooth muscle cells; epithelial membrane antigen (EMA) in epithelial cells; and CD34, Factor VIII and vascular endothelial growth factor (VEGF) in endothelial cells. Matrix metalloproteinases (MMPs) -2 and -9, and transforming growth factor-beta (TGF-β) were used to demonstrate cytokine release from macrophages, leukocytes, fibroblasts and myofibroblasts. Pannus appeared as a tough and thick tissue hyperplasia which began from outside the suture ring in the periannular region and extended to the inflow and outflow surfaces of the prosthetic valves. Histopathological analysis showed the pannus tissue to consist of chronic inflammatory cells (lymphocytes, plasma cells, macrophages and foreign body giant cells), spindle cells such as myofibroblasts, capillary blood vessels and endothelial cells laying down the lumens. Calcification was present in the pannus tissue of 19 explanted prostheses. Immunohistochemical studies revealed positive α-SMA expression in all patients, whereas 60.5% of patients were positive for desmin, 50% for EMA, 42.1% for VEGF, 39.5% for TBF-β, 42.1% for MMP-2, 86.8% for CD34, and 97.4% for Factor VIII. MMP-9 was negative in all patients. Pannus tissue appears to be formed as the result of a neointimal response in periannular regions of prosthetic valves that consist of periannular tissue migration, myofibroblast and extracellular matrix proliferation with vascular components. It is a chronic active process in which mediators such as TGF-β, VEGF and MMP-2 play roles in both matrix formation and degradation.
Soumoulou, Juan Bautista; Cianciulli, Tomás Francisco; Zappi, Andrea; Cozzarin, Alberto; Saccheri, María Cristina; Lax, Jorge Alberto; Guidoin, Robert; Zhang, Ze
2015-01-01
Pannus formation is a rare complication and occurs almost exclusively in mechanical prosthetic valves. It consists of fibrous tissue that covers the surface of the prosthesis either concentrically or eccentrically, resulting in valve dysfunction. The pathophysiology seems to be associated to a chronic inflammatory process that explains the late and insidious clinical presentation. This diagnosis should be considered in patients with high transvalvular gradients on transthoracic echo, and workup should be completed with fluoroscopy and transesophageal echocardiography. Treatment is always surgical and recurrence is rare. We present a case of pannus formation in a prosthetic aortic valve and a review of the literature regarding this disorder. PMID:25914791
Soumoulou, Juan Bautista; Cianciulli, Tomás Francisco; Zappi, Andrea; Cozzarin, Alberto; Saccheri, María Cristina; Lax, Jorge Alberto; Guidoin, Robert; Zhang, Ze
2015-04-26
Pannus formation is a rare complication and occurs almost exclusively in mechanical prosthetic valves. It consists of fibrous tissue that covers the surface of the prosthesis either concentrically or eccentrically, resulting in valve dysfunction. The pathophysiology seems to be associated to a chronic inflammatory process that explains the late and insidious clinical presentation. This diagnosis should be considered in patients with high transvalvular gradients on transthoracic echo, and workup should be completed with fluoroscopy and transesophageal echocardiography. Treatment is always surgical and recurrence is rare. We present a case of pannus formation in a prosthetic aortic valve and a review of the literature regarding this disorder.
Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.
Cianciulli, Tomás F; Lax, Jorge A; Saccheri, María C; Guidoin, Robert; Salvado, César M; Fernández, Adrián J; Prezioso, Horacio A
2008-01-01
The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.
Redo surgery risk in patients with cardiac prosthetic valve dysfunction
Maciejewski, Marek; Piestrzeniewicz, Katarzyna; Bielecka-Dąbrowa, Agata; Piechowiak, Monika; Jaszewski, Ryszard
2011-01-01
Introduction The aim of the study was to analyse the risk factors of early and late mortality in patients undergoing the first reoperation for prosthetic valve dysfunction. Material and methods A retrospective observational study was performed in 194 consecutive patients (M = 75, F = 119; mean age 53.2 ±11 years) with a mechanical prosthetic valve (n = 103 cases; 53%) or bioprosthesis (91; 47%). Univariate and multivariate Cox statistical analysis was performed to determine risk factors of early and late mortality. Results The overall early mortality was 18.6%: 31.4% in patients with symptoms of NYHA functional class III-IV and 3.4% in pts in NYHA class I-II. Multivariate analysis identified symptoms of NYHA class III-IV and endocarditis as independent predictors of early mortality. The overall late mortality (> 30 days) was 8.2% (0.62% year/patient). Multivariate analysis identified age at the time of reoperation as a strong independent predictor of late mortality. Conclusions Reoperation in patients with prosthetic valves, performed urgently, especially in patients with symptoms of NYHA class III-IV or in the case of endocarditis, bears a high mortality rate. Risk of planned reoperation, mostly in patients with symptoms of NYHA class I-II, does not differ from the risk of the first operation. PMID:22291767
Calik, Eyup Serhat; Limandal, Husnu Kamil; Arslan, Umit; Tort, Mehmet; Yildiz, Ziya; Bayram, Ednan; Dag, Ozgur; Kaygin, Mehmet Ali; Erkut, Bilgehan
2015-12-14
Leaflet escape of prosthetic valve is rare but potentially life threatening. Early diagnosis is essential on account of avoiding mortality, and emergency surgical correction is compulsory. This complication has previously been reported for both monoleaflet and bileaflet valve models. A 30-year-old man who had undergone mitral valve replacement with a bileaflet valve 8 years prior at another center was admitted with acute-onset with cardiogenic shock as an emergency case. Transthoracic echocardiograms showed acute-starting severe mitral regurgitation associated with prosthetic mitral valve. There was a suspicious finding of a single prosthetic mitral leaflet. But the problem related with the valve wasn't specifically determined. The patient underwent emergent surgery for replacement of the damaged prosthetic valves immediately. There was no tissue impingement and thrombosis, one of the two leaflets was absent, and there were no signs of endocarditis or pannus formation in the prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet during surgery. The damaged valve was removed and a replacement 29 mm bileaflet mechanical valve was inserted by right lateral thoracotomy. After post-operative week one, the abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the left femoral artery. Fifteen days after the surgery the escaped leaflet was removed safely from the left femoral artery and the patient made a complete recovery. The escaped leaflet showed a fracture of one of the pivot systems caused by structural failure. Early cardiac surgery should be applied because of life-threatening problems.
Larrieu, A J; Puglia, E; Allen, P
1982-08-01
The case of a patient who survived strut fracture and embolization of a Björk-Shiley mitral prosthetic disc is presented. Prompt surgical treatment was directly responsible for survival. In addition, computerized axial tomography of the abdomen aided in localizing and retrieving the embolized disc, which was lodged at the origin of the superior mesenteric artery. A review of similar case reports from the literature supports our conclusions that the development of acute heart failure and absent or muffled prosthetic heart sounds in a patient with a Björk-Shiley prosthetic heart valve inserted prior to 1978 should raise the possibility of valve dysfunction and lead to early reoperation.
Lancellotti, Patrizio; Pibarot, Philippe; Chambers, John; Edvardsen, Thor; Delgado, Victoria; Dulgheru, Raluca; Pepi, Mauro; Cosyns, Bernard; Dweck, Mark R; Garbi, Madalina; Magne, Julien; Nieman, Koen; Rosenhek, Raphael; Bernard, Anne; Lowenstein, Jorge; Vieira, Marcelo Luiz Campos; Rabischoffsky, Arnaldo; Vyhmeister, Rodrigo Hernández; Zhou, Xiao; Zhang, Yun; Zamorano, Jose-Luis; Habib, Gilbert
2016-06-01
Prosthetic heart valve (PHV) dysfunction is rare but potentially life-threatening. Although often challenging, establishing the exact cause of PHV dysfunction is essential to determine the appropriate treatment strategy. In clinical practice, a comprehensive approach that integrates several parameters of valve morphology and function assessed with 2D/3D transthoracic and transoesophageal echocardiography is a key to appropriately detect and quantitate PHV dysfunction. Cinefluoroscopy, multidetector computed tomography, cardiac magnetic resonance imaging, and to a lesser extent, nuclear imaging are complementary tools for the diagnosis and management of PHV complications. The present document provides recommendations for the use of multimodality imaging in the assessment of PHVs. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
González-Santos, Jose María; Arnáiz-García, María Elena; Dalmau-Sorlí, María José; Sastre-Rincón, Jose Alfonso; Hernández-Hernández, Jesús; Pérez-Losada, María Elena; Sagredo-Meneses, Víctor; López-Rodríguez, Javier
2016-10-01
A patient who underwent previous implantation of a mitral valve replacement with a Björk-Shiley Delrin (BSD) mitral valve prosthesis during infancy was admitted to our institution 43 years later after an episode of syncope and cardiac arrest. Under extreme hemodynamic instability, a mitral valve prosthetic dysfunction causing massive mitral regurgitation was identified. The patient underwent an emergent cardiac operation, and a complete disc fracture with partial disc migration was found. Exceptional cases of mechanical prosthetic heart valve fracture exist. We report the first case of complete transversal disc rupture of a BSD mitral valve prosthesis after the longest period of implantation ever reported in that position. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Gündüz, Sabahattin; Özkan, Mehmet; Kalçik, Macit; Gürsoy, Ozan Mustafa; Astarcioğlu, Mehmet Ali; Karakoyun, Süleyman; Aykan, Ahmet Çağri; Biteker, Murat; Gökdeniz, Tayyar; Kaya, Hasan; Yesin, Mahmut; Duran, Nilüfer Ekşi; Sevinç, Deniz; Güneysu, Tahsin
2015-12-01
Distinguishing pannus and thrombus in patients with prosthetic valve dysfunction is essential for the selection of proper treatment. We have investigated the utility of 64-slice multidetector computed tomography (MDCT) in distinguishing between pannus and thrombus, the latter amenable to thrombolysis. Sixty-two (23 men, mean age 44±14 years) patients with suspected mechanical prosthetic valve dysfunction assessed by transesophageal echocardiography were included in this prospective observational trial. Subsequently, MDCT was performed before any treatment was started. Periprosthetic masses were detected by MDCT in 46 patients, and their attenuation values were measured as Hounsfield Units (HU). Patients underwent thrombolysis unless contraindicated, and those with a contraindication or failed thrombolysis underwent surgery. A mass which was completely lysed or surgically detected as a clot was classified as thrombus, whereas a mass which was surgically detected as tissue overgrowth was classified as pannus. A definitive diagnosis could be achieved in 37 patients with 39 MDCT masses (22 thrombus and 17 pannus). The mean attenuation value of 22 thrombotic masses was significantly lower than that in 17 pannus (87±59 versus 322±122; P<0.001). Area under the receiver operating characteristic curve was 0.96 (95% confidence interval: 0.91-0.99; P<0.001), and a cutoff point of HU≥145 provided high sensitivity (87.5%) and specificity (95.5%) in discriminating pannus from thrombus. Complete lysis was more common for masses with HU<90 compared with those with HU 90 to 145 (100% versus 42.1%; P=0.007). Sixty-four slice MDCT is helpful in identifying masses amenable to thrombolysis in patients with prosthetic valve dysfunction. A high (HU≥145) attenuation suggests pannus overgrowth, whereas a lower value is associated with thrombus formation. A higher attenuation (HU>90) is associated with reduced lysis rates. © 2015 American Heart Association, Inc.
Re-operation for aortic and mitral prosthetic dysfunctions.
Kaul, T K; Sastry, M R; Mercer, J L; Meade, J B
1985-01-01
The overall incidence of re-operation and prosthetic valve endocarditis was low in the present series as mechanical prostheses were used predominantly. The prosthetic dysfunctions were less frequent following the primary implantation with Bjork Shiley prostheses, but high operative risk was associated with the clotted Bjork Shiley prostheses. We also had unusual experience of strut fracture and sticking of Bjork Shiley discs in the closed position in both aortic and mitral positions. The early deaths were nil since the use of cardioplegic protection. Intra-operative bleeding due to adhesions can be minimised by using synthetic or heterologous pericardium during the primary operation.
Fracture and embolization of a Björk-Shiley disc. Fatal failure of a prosthetic mitral valve.
Norenberg, D D; Evans, R W; Gundersen, A E; Abellera, R M
1977-12-01
A case of fracture of the disc occluder of a Bjork-Shiley mitral prosthesis with embolization of the disc fragments to distal aorta is presented. The possibility of valve dysfunction and the diagnostic value of echocardiography should be considered whenever acute heart failure occurs in a patient with an artificial valve.
Prosthetic valve endocarditis due to Propionibacterium acnes.
van Valen, Richard; de Lind van Wijngaarden, Robert A F; Verkaik, Nelianne J; Mokhles, Mostafa M; Bogers, Ad J J C
2016-07-01
To study the characteristics of patients with Propionibacterium acnes prosthetic valve endocarditis (PVE) who required surgery. A single-centre retrospective cohort study was conducted during a 7-year period. Patients with definite infective P. acnes endocarditis, according to the modified Duke criteria, were included. An extended culture protocol was applied. Information on medical health status, surgery, antibiotic treatment and mortality was obtained. Thirteen patients fulfilled the criteria for P. acnes endocarditis (0.53% of 2466 patients with valve replacement in a 7-year period). All patients were male and had a previous valve replacement. The health status of patients was poor at diagnosis of P. acnes PVE. Most patients (11 of 13, 85%) were admitted with signs of heart failure due to a significant paravalvular leak; 2 of 13 (15%) patients presented with septic emboli. Twelve patients needed redo surgery, whereas one could be treated with antibiotic therapy only. The time between the index surgery and presentation with P. acnes PVE varied between 5 and 135 months (median 26.5 months). Replacement and reconstruction of the dysfunctional valve and affected anatomical structures was mainly performed with a mechanical valve (n = 5, 42%) or a (bio-) Bentall prosthesis (n = 6, 50%). Antibiotic therapy consisted of penicillin with or without rifampicin for 6 weeks after surgery. The mortality in this series was low (n = 1, 8%) and no recurrent endocarditis was found during a median follow-up of 38 months. Propionibacterium acnes PVE is a rare complication after valve surgery. Redo surgery is often required. Treatment of the dysfunctional prosthetic aortic valve most often consists of root replacement, in combination with antibiotic therapy. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
An unusual cause of hemolysis in a patient with an aortic valved conduit replacement.
Allman, Christine; Rajaratnam, Rohan; Kachwalla, Hashim; Hughes, Clifford F; Bannon, Paul; Leung, Dominic Y
2003-02-01
Hemolytic anemia is a well-known but uncommon complication in patients with prosthetic heart valves. It is most commonly a result of prosthetic valve dysfunction, periprosthetic valvular regurgitation, or both. We report a case of a 41-year-old man who had a previous aortic valve and root replacement for acute proximal aortic dissection, now presenting with hemolytic anemia. This was a result of flow obstruction at the distal anastomosis of the aortic conduit by the presence of multiple dissection flaps resulting in severe flow turbulence. Although the pathology was at the blind spot for transesophageal echocardiography, the dissection flaps, the flow turbulence, and the degree of obstruction were well-demonstrated by this technique after careful manipulation of the probe and a high index of suspicion.
Disc dislodgment in Björk Shiley mitral valve prosthesis: two successfully operated cases.
Dubernet, J; Irarrázaval, M J; Urzúa, J; Maturana, G; Morán, S; Lema, G; Asenjo, F; Fajuri, A
1986-02-01
Two patients with Björk Shiley mitral valve replacement had migration and embolization of the occluding disc. One patient suffered migration of the disc a few hours after surgery and the other had a strut fracture with disc translocation six years after the initial operation. Clinical signs in both cases were pulmonary edema, cardiogenic shock, and absence of prosthetic sounds. Both patients were reoperated on an emergency basis, recovering after a complicated postoperative course. They are on functional Class I, 8 and 1 years later, respectively, with their dislodged discs still in the abdominal aorta. The only hope for survival in these patients is emergency reoperation, once the prosthetic mitral valve dysfunction is confirmed.
D'Ascenzo, Fabrizio; Benedetto, Umberto; Bianco, Matteo; Conrotto, Federico; Moretti, Claudio; D'Onofrio, Augusto; Agrifoglio, Marco; Colombo, Antonio; Ribichini, Flavio; Tarantini, Giuseppe; D'Amico, Maurizio; Salizzoni, Stefano; Rinaldi, Mauro
2017-12-08
The safety and efficacy of single vs. dual antiplatelet therapy (DAPT) in patients undergoing TAVI remain to be addressed. The aim of our study was to evaluate the usefulness of a DAPT compared to a single platelet therapy in patients undergoing TAVI with a balloon-expandable prosthesis. All consecutive patients enrolled in the ITER registry were included. Patients undergoing TAVI discharged with aspirin alone were compared to those taking DAPT before and after selection using propensity score with matching. Subgroup analysis was performed for those on OAT. Prosthetic heart valve dysfunction at follow-up was the primary endpoint, whereas all-cause death, cardiovascular death, bleedings, vascular complications and cerebrovascular accidents were the secondary ones. From 1,364 patients, after propensity score with matching, 605 were selected for each group (aspirin alone vs. DAPT). At 30 days, rates of VARC mortality were lower in patients with aspirin alone (1.5% vs. 4.1%, p=0.003), mainly driven by a reduction of major vascular complications (5.3% vs. 10.7%, p<0.001) and of major bleedings (6.6% vs. 11.5%, p<0.001), without a difference in prosthetic heart valve dysfunction after 45±14 months (2.8% vs. 3.0%, p=0.50). These results were confirmed on multivariable analysis. After TAVI with a balloon-expandable prosthesis, aspirin alone does not increase the risk of prosthetic valve dysfunction, and reduces the risk of periprocedural complications and of 30-day all-cause death.
Acute obstruction by Pannus in patients with aortic medtronic-hall valves: 30 years of experience.
Ellensen, Vegard Skalstad; Andersen, Knut Sverre; Vitale, Nicola; Davidsen, Einar Skulstad; Segadal, Leidulf; Haaverstad, Rune
2013-12-01
Acute dysfunction of mechanical aortic valve prostheses is a life-threatening adverse event. Pannus overgrowth, which is fibroelastic hyperplasia originating from the periannular area, is one cause of dysfunction. The aim of this study was to determine the annual incidence of readmittance resulting from acute obstruction caused by pannus during 30 years of observation in patients with Medtronic-Hall aortic valve prostheses and to analyze the risk factors associated with pannus development. From 1982 to 2004, 1,187 patients in our department underwent aortic valve replacement with Medtronic-Hall mechanical monoleaflet valve prostheses. As of December 31, 2012, 27 of these patients (2.3%) had presented with acute valve dysfunction caused by pannus obstruction. The annual incidence of pannus was 0.7 per 1,000. The median time from the primary operation to prosthetic dysfunction was 11.1 years (range, 1.2 to 26.8 years). Of the 20 patients who underwent reoperation, 2 died. Seven patients died before reoperation. Women had a higher risk for the development of obstructing pannus, and patients with pannus obstruction were younger. Valve size was not an independent risk factor. Women and younger patients are at higher risk for pannus development. When acute dysfunction by pannus is suspected in a mechanical aortic valve, an immediate echocardiogram and an emergency aortic valve replacement should be carried out because of the potential of a fatal outcome. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Dysfunction of mechanical heart valve prosthesis: experience with surgical management in 48 patients
Ma, Wei-Guo; Hou, Bin; Abdurusul, Adiljan; Gong, Ding-Xu; Tang, Yue; Chang, Qian; Xu, Jian-Ping
2015-01-01
Background Dysfunction of mechanical heart valve prostheses is an unusual but potentially lethal complication after mechanical prosthetic valve replacement. We seek to report our experience with mechanical valve dysfunction regarding etiology, surgical techniques and early outcomes. Methods Clinical data of 48 patients with mechanical valve dysfunction surgically treated between October 1996 and June 2011 were analyzed. Results Mean age was 43.7±10.9 years and 34 were female (70.8%). The median interval from primary valve implantation to dysfunction was 44.5 months (range, 1 hour to 20 years). There were 21 emergent and 27 elective reoperations. The etiology was thrombosis in 19 cases (39.6%), pannus in 12 (25%), thrombosis and pannus in 11 (22.9%), improper disc orientation in 2 (4.1%), missing leaflet in 1 (2.1%), excessively long knot end in 1 (2.1%), endogenous factor in 1 (2.1%) and unidentified in 1 (2.1%). Surgical procedure was mechanical valve replacement in 37 cases (77.1%), bioprosthetic valve replacement in 7 (14.9%), disc rotation in 2 (4.2%) and excision of excessive knot end in 1 (2.1%). Early deaths occurred in 7 patients (14.6%), due to low cardiac output in 3 (6.3%), multi-organ failure in 2 (4.2%) and refractory ventricular fibrillation in 2 (4.2%). Complications occurred in 10 patients (20.8%). Conclusions Surgical management of mechanical valve dysfunction is associated with significant mortality and morbidity. Earlier identification and prompt reoperation are vital to achieving better clinical outcomes. The high incidence of thrombosis in this series highlights the need for adequate anticoagulation and regular follow-up after mechanical valve replacement. PMID:26793354
Unusual cause of central aortic prosthetic regurgitation during transcatheter replacement.
López-Mínguez, José Ramón; Millán-Núñez, Victoria; González-Fernández, Reyes; Nogales-Asensio, Juan Manuel; Fuentes-Cañamero, María Eugenia; Merchán-Herrera, Antonio
2016-04-01
Transcatheter aortic valve replacement (TAVR) is an increasingly common procedure for the treatment of aortic stenosis in elderly patients with comorbidities that prevent the use of standard surgery. It has been shown that implantation without aortic regurgitation is related to lower mortality. Mild paravalvular regurgitation is inevitable in some cases due to calcification of the aortic annulus and its usually somewhat elliptical shape. Central regurgitation is less common, but has been associated with valve overdilatation in cases in which reduction of paravalvular regurgitation was attempted after the initial inflation. However, there are no reported cases of central prosthetic aortic regurgitation due to acute LV dysfunction. We report a case in which central aortic regurgitation occurred due to transient ventricular dysfunction secondary to occlusion of the right coronary artery by an embolus. The regurgitation disappeared after thrombus aspiration and normal ventricular function was immediately recovered. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.
Infective endocarditis: outcome in surviving patients with intracardiac complications.
Mocchegiani, Roberto; Pergolini, Martina; Nataloni, Maura
2007-03-01
The purpose of this study was to assess the outcome of 15 patients who survived infective endocarditis with abscesses and other intracardiac complications. Abscesses were associated with native valve endocarditis in seven patients and prosthetic valve endocarditis in eight patients; fistulas were observed in three patients, and subaortic perforation in three patients. Sensitivity for the detection of abscesses was 42.8% and 92.8% using transthoracic and transoesophageal echocardiography, respectively. Eleven patients underwent surgical treatment with no operative mortality, whereas four patients were only medically treated. During follow-up (mean 8.26 years), two patients died (13%) and six recurrences (five early and one late prosthetic valve endocarditis) required re-intervention for prosthesis dysfunction (40%); an improvement in New York Heart Association class in survivors and no changes in echocardiographic lesions were observed. Infective intracardiac complications do not seem to significantly reduce the overall survival (87%) of patients at long-term follow-up.
21 CFR 870.3945 - Prosthetic heart valve sizer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prosthetic heart valve sizer. 870.3945 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3945 Prosthetic heart valve sizer. (a) Identification. A prosthetic heart valve sizer is a device used to measure the size of the...
21 CFR 870.3945 - Prosthetic heart valve sizer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Prosthetic heart valve sizer. 870.3945 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3945 Prosthetic heart valve sizer. (a) Identification. A prosthetic heart valve sizer is a device used to measure the size of the...
21 CFR 870.3945 - Prosthetic heart valve sizer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Prosthetic heart valve sizer. 870.3945 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3945 Prosthetic heart valve sizer. (a) Identification. A prosthetic heart valve sizer is a device used to measure the size of the...
21 CFR 870.3945 - Prosthetic heart valve sizer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Prosthetic heart valve sizer. 870.3945 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3945 Prosthetic heart valve sizer. (a) Identification. A prosthetic heart valve sizer is a device used to measure the size of the...
21 CFR 870.3945 - Prosthetic heart valve sizer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Prosthetic heart valve sizer. 870.3945 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3945 Prosthetic heart valve sizer. (a) Identification. A prosthetic heart valve sizer is a device used to measure the size of the...
Shiran, Avinoam; Sagie, Alex
2009-02-03
Tricuspid regurgitation (TR) in patients with mitral valve (MV) disease is associated with poor outcome and predicts poor survival, heart failure, and reduced functional capacity. It is common if left untreated after MV replacement mainly in rheumatic patients, but it is also common in patients with ischemic mitral regurgitation. It is less common, however, in those with degenerative mitral regurgitation. It might appear many years after surgery and might not resolve after correcting the MV lesion. Late TR might be caused by prosthetic valve dysfunction, left heart disease, right ventricular (RV) dysfunction and dilation, persistent pulmonary hypertension, chronic atrial fibrillation, or by organic (mainly rheumatic) tricuspid valve disease. Most commonly, late TR is functional and isolated, secondary to tricuspid annular dilation. Outcome of isolated tricuspid valve surgery is poor, because RV dysfunction has already occurred at that point in many patients. MV surgery or balloon valvotomy should be performed before RV dysfunction, severe TR, or advanced heart failure has occurred. Tricuspid annuloplasty with a ring should be performed at the initial MV surgery, and the tricuspid annulus diameter (>or=3.5 cm) is the best criterion for performing the annuloplasty. In this article we will review the current data available for understanding the prognostic implications, mechanism, and management of TR in patients with MV disease.
The left atrial catheter: its uses and complications.
Leitman, B S; Naidich, D P; McGuinness, G; McCauley, D I
1992-11-01
The authors describe the radiographic appearance of the left atrial catheter, a widely used postsurgical intracardiac device. Recognition of the characteristic appearance of this catheter should be of value in detection of potential complications, including line fracture with resultant retention and/or embolization, infection, prosthetic valve dysfunction, and even cardiac tamponade.
AB0 blood types: impact on development of prosthetic mechanical valve thrombosis
Astarcıoğlu, Mehmet Ali; Kalçık, Macit; Yesin, Mahmut; Gürsoy, Mustafa Ozan; Şen, Taner; Karakoyun, Süleyman; Gündüz, Sabahattin; Özkan, Mehmet
2016-01-01
Objective: The non-O alleles of the ABO genotype have been associated with an increased risk of thrombosis. We aimed to assess the association between blood group status and prosthetic valve thrombosis. Methods: The association between AB0 blood group status and prosthetic valve thrombosis was assessed in this retrospective study. Transesophageal echocardiography was performed in 149 patients with a diagnosis of prosthetic valve thrombosis and in 192 control subjects. Results: Non-0 blood group type (p<0.001), presence of NYHA class III-IV status (p<0.001), and central nervous system (p<0.001) and non-central nervous system (p<0.001) emboli were significantly more prevalent in prosthetic valve thrombosis patients than in the control subjects. The incidence of ineffective anticoagulation was higher in patients with prosthetic valve thrombosis than in controls (p<0.001), as was the presence of moderate to severe left atrial spontaneous echo contrast (p<0.001). The non-0 blood prosthetic valve thrombosis subgroup had a higher incidence of obstructive thrombi and central nervous system thrombotic events than having 0 blood prosthetic valve thrombosis subgroup. Non-0 blood group, ineffective anticoagulation, left atrial spontaneous echo contrast, and a poor NYHA functional capacity were identified to be the predictors of prosthetic valve thrombosis. Conclusion: Our data demonstrate that patients with non-0 compared with 0 blood groups have higher incidence of prosthetic valve thrombosis and central nervous system embolism and similar rates of non-central nervous system embolism at presentation compared with 0 blood group type. Thus, non-O blood group may be a risk factor that may be prone to the development of prosthetic valve thrombosis in patients with prosthetic heart valves. PMID:27488753
Transhepatic implant of a trimmed Melody™ valved stent in tricuspid position in a 1-year-old infant.
Cools, Bjorn; Rega, Filip; Gewillig, Marc
2017-02-15
Percutaneous valved stent implantation is precluded in small infants because large delivery sheaths and large devices. We describe a procedure in a 1-year-old boy in whom a 19 mm Epic™ valve in tricuspid position had become dysfunctional. As the internal diameter of the prosthetic valve was about 16 mm, the only available valve was the Melody™ valved stent. Technical modifications were required to address issues like venous access, the bulky delivery system, and the length of the valved stent. The Melody™ valved stent was surgically trimmed and mounted on a 16 mm Tyshak balloon, access was provided transhepatically through a short 18 Fr sheath. After deployment, the intrahepatic route was sealed with two vascular plugs (8 and 10 mm) in tandem. The procedure was uncomplicated with perfect valve function 18 months after implant. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Late outcome analysis of the Braile Biomédica® pericardial valve in the aortic position
Azeredo, Lisandro Gonçalves; Veronese, Elinthon Tavares; Santiago, José Augusto Duncan; Brandão, Carlos Manuel de Almeida; Pomerantzeff, Pablo Maria Alberto; Jatene, Fabio Biscegli
2014-01-01
Objective Aortic valve replacement with Braile bovine pericardial prosthesis has been routinely done at the Heart Institute of the Universidade de São Paulo Medical School since 2006. The objective of this study is to analyze the results of Braile Biomédica® aortic bioprosthesis in patients with aortic valve disease. Methods We retrospectively evaluated 196 patients with aortic valve disease submitted to aortic valve replacement with Braile Biomédica® bovine pericardial prosthesis, between 2006 and 2010. Mean age was 59.41±16.34 years and 67.3% were male. Before surgery, 73.4% of patients were in NYHA functional class III or IV. Results Hospital mortality was 8.16% (16 patients). Linearized rates of mortality, endocarditis, reintervention, and structural dysfunction were 1.065%, 0.91%, 0.68% and 0.075% patients/year, respectively. Actuarial survival was 90.59±2.56% in 88 months. Freedom from reintervention, endocarditis and structural dysfunction was respectively 91.38±2.79%, 89.84±2.92% and 98.57±0.72% in 88 months. Conclusion The Braile Biomédica® pericardial aortic valve prosthesis demonstrated actuarial survival and durability similar to that described in the literature, but further follow up is required to assess the incidence of prosthetic valve endocarditis and structural dysfunction in the future. PMID:25372903
Vilacosta, Isidre; Olmos, Carmen; de Agustín, Alberto; López, Javier; Islas, Fabián; Sarriá, Cristina; Ferrera, Carlos; Ortiz-Bautista, Carlos; Sánchez-Enrique, Cristina; Vivas, David; San Román, Alberto
2015-11-01
Echocardiography, transthoracic and transoesophageal, plays a key role in the diagnosis and prognosis assessment of patients with infective endocarditis. It constitutes a major Duke criterion and is pivotal in treatment guiding. Seven echocardiographic findings are major criteria in the diagnosis of infective endocarditis (IE) (vegetation, abscess, pseudoaneurysm, fistulae, new dehiscence of a prosthetic valve, perforation and valve aneurysm). Echocardiography must be performed as soon as endocarditis is suspected. Transoesophageal echocardiography should be done in most cases of left-sided endocarditis to better define the anatomic lesions and to rule out local complications. Transoesophageal echocardiography is not necessary in isolated right-sided native valve IE with good quality transthoracic examination and unequivocal echocardiographic findings. Echocardiography is a very useful tool to assess the prognosis of patients with IE at any time during the course of the disease. Echocardiographic predictors of poor outcome include presence of periannular complications, prosthetic dysfunction, low left ventricular ejection fraction, pulmonary hypertension and very large vegetations.
Subvalvular pannus and thrombosis in a mitral valve prosthesis.
Kim, Gun Ha; Yang, Dong Hyun; Kang, Joon-Won; Kim, Dae-Hee; Jung, Sung-Ho; Lim, Tae-Hwan
2016-01-01
A 69-year-old female underwent cardiac CT to evaluate prosthetic valve (PHV) dysfunction detected on echocardiography. A CT coronal and en face views of the mitral annular plane showed a low-density, mass-like lesion on the left atrial side of the PHV and a high-density, plate-like lesion on the left ventricular side of PHV. A repeat of the mitral valve replacement was performed, and preoperative CT findings of both the thrombus on the left atrial side and pannus formation on the LV side were confirmed in the operative findings. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
21 CFR 870.3935 - Prosthetic heart valve holder.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...
21 CFR 870.3935 - Prosthetic heart valve holder.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...
21 CFR 870.3935 - Prosthetic heart valve holder.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...
21 CFR 870.3935 - Prosthetic heart valve holder.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...
21 CFR 870.3935 - Prosthetic heart valve holder.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...
Trauma: An Unusual Cause of Endocarditis.
Braga, Ana; Marques, Marta; Abecacis, Miguel; Neves, José Pedro
2017-01-01
Infective endocarditis (IE) remains a dangerous condition with considerable associated mortality. Usual risk factors for IE include the presence of a prosthetic heart valve, structural or congenital heart disease, intravenous drug use, and a recent history of invasive procedures. The authors describe the case report of a patient with IE having trauma as an unusual risk factor. A 33-year old male patient was referred to our department due to infective endocarditis. The patient had a fever of unknown origin for 15 days before going to the emergency department. After admission it was identified by transthoracic echocardiography a 14mm posterior abscess of the aortic valve provoking major aortic regurgitation with moderate LV dysfunction. After careful evaluation of the clinical history it was found that the patient had a known bicuspid aortic valve with follow-up since the age of 14. All other usual risk factors for IE were excluded, including intravenous drug use and recent history of invasive procedures. The only relevant previous event was a traumatic haemathoma in his left jaw caused by a working accident with an iron beam in a construction site as the patient is a civil engineer. Vancomycin plus gentamicin were empirically started after blood cultures taken. The isolated infective agent was Staphylococcus lugdunensis methicillin sensitive and the antibiotherapy was de-escalated to flucloxacilin plus gentamicin. Due to cardiac dysfunction the patient was submitted to cardiac surgery on the fourth day of directed antibiotic therapy and a replacement of the aortic valve by a mechanical prosthetic valve and closure of the abscess with bovine pericardial patch was performed. The valve sent to microbiology evaluation showed the same infective provocative agent. The patient had a good clinical and laboratorial recovery completing the 42-day antibiotic scheme. After antibiotherapy period completion, echocardiography was repeated and the abscess found was larger then the previous one, presenting itself like an aortic pseudo aneurysm. The patient was resubmitted to surgery with re-closure of the initial abscess with autologous pericardial patch and replacement of the prosthetic mechanical valve for an undersized one. The patient was discharger clinically well, having a complete normal life at the moment. This clinical case illustrates trauma as an unusual cause of endocarditis and emphasizes the importance of a detailed clinical history.
Prosthetic Aortic Valves: Challenges and Solutions
Musumeci, Lucia; Jacques, Nicolas; Hego, Alexandre; Nchimi, Alain; Lancellotti, Patrizio; Oury, Cécile
2018-01-01
Aortic Valve Disease (AVD) is the most common Valvular Heart Disease (VHD), affecting millions of people worldwide. Severe AVD is treated in most cases with prosthetic aortic valve replacement, which involves the substitution of the native aortic valve with a prosthetic one. In this review we will discuss the different types of prosthetic aortic valves available for implantation and the challenges faced by patients, medical doctors, researchers and manufacturers, as well as the approaches that are taken to overcome them. PMID:29868612
Afebrile Pannus-Induced Blood Culture-Negative Mechanical Valve Endocarditis.
Matsukuma, Seiji; Eishi, Kiyoyuki; Tanigawa, Kazuyoshi; Miura, Takashi; Matsumaru, Ichiro; Hisatomi, Kazuki; Tsuneto, Akira
2016-12-01
The diagnosis of prosthetic valve endocarditis may be challenging in patients with an atypical clinical presentation. Virtually all infections associated with mechanical prosthetic valves are localized to the prosthesis-tissue junction at the sewing ring and are accompanied by tissue destruction around the prosthesis. Because the orifice of the mechanical prosthetic valve is made of metal and pyrolytic carbon, which do not enable the adherence of microorganisms, any vegetation originating from the interior of the valve orifice is usually rare. Here we present a rare case of pannus-induced mechanical prosthetic valve endocarditis that was difficult to diagnose. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Bradley, Scott M
2013-10-01
The contents of this article were presented in the session "Aortic insufficiency in the teenager" at the congenital parallel symposium of the 2013 Society of Thoracic Surgeons (STS) annual meeting. The accompanying articles detail the approaches of aortic valve repair and the Ross procedure.(1,2) The current article focuses on prosthetic valve replacement. For many young patients requiring aortic valve surgery, either aortic valve repair or a Ross procedure provides a good option. The advantages include avoidance of anticoagulation and potential for growth. In other patients, a prosthetic valve is an appropriate alternative. This article discusses the current state of knowledge regarding mechanical and bioprosthetic valve prostheses and their specific advantages relative to valve repair or a Ross procedure. In current practice, young patients requiring aortic valve surgery frequently undergo valve replacement with a prosthetic valve. In STS adult cardiac database, among patients ≤30 years of age undergoing aortic valve surgery, 34% had placement of a mechanical valve, 51% had placement of a bioprosthetic valve, 9% had aortic valve repair, and 2% had a Ross procedure. In the STS congenital database, among patients 12 to 30 years of age undergoing aortic valve surgery, 21% had placement of a mechanical valve, 18% had placement of a bioprosthetic valve, 30% had aortic valve repair, and 24% had a Ross procedure. In the future, the balance among these options may be altered by design improvements in prosthetic valves, alternatives to warfarin, the development of new patch materials for valve repair, and techniques to avoid Ross autograft failure.
Gürsoy, Mustafa Ozan; Kalçık, Macit; Yesin, Mahmut; Karakoyun, Süleyman; Bayam, Emrah; Gündüz, Sabahattin; Özkan, Mehmet
2016-01-01
Prosthetic valve thrombosis is one of the major causes of primary valve failure, which can be life-threatening. Multimodality imaging is necessary for determination of leaflet immobilization, cause of underlying pathology (thrombus versus pannus or both), and whether thrombolytic therapy attempt in the patient would be successful or surgery is needed. Current guidelines for the management of prosthetic valve thrombosis lack definitive class I recommendations due to lack of randomized controlled trials, and usually leave the choice of treatment to the clinician’s experience. In this review, we aimed to summarize the pathogenesis, diagnosis, and management of mechanical prosthetic valve thrombosis. PMID:28005024
Uhrin, Gábor Balázs; Jensen, Rasmus Hare; Korup, Eva; Grønlund, Jens; Hjort, Ulla; Moser, Claus; Arendrup, Maiken Cavling; Schønheyder, Henrik Carl
2015-01-01
We report Aspergillus delacroxii (formerly Aspergillus nidulans var. echinulatus) causing recurrent prosthetic valve endocarditis. The fungus was the sole agent detected during replacement of a mechanical aortic valve conduit due to abscess formation. Despite extensive surgery and anti-fungal treatment, the patient had a cerebral hemorrhage 4 months post-surgery prompting a diagnosis of recurrent prosthetic valve endocarditis and fungemia. PMID:26909244
Hassoulas, Joannis; Patrianakos, Alexandros P; Parthenakis, Fragiskos I; Vardas, Panos E
2009-01-01
We present a 76-year-old woman with infective endocarditis of a prosthetic aortic valve. The course of her illness started with an ischaemic stroke and she was admitted with prolonged fever and an episode of loss of consciousness. Echocardiography revealed acute aortic regurgitation and dehiscence of the prosthetic valve with excessive "rocking motion", aortic abscesses and left ventricular outflow obstruction caused by a semilunar shelf of tissue probably due to endocarditis vegetations. She underwent an urgent surgical procedure that confirmed the echocardiographic findings. Our case report reinforces the value of early diagnosis in the presence of a high clinical suspicion of prosthetic valve endocarditis. An extended workup, including transoesophageal echocardiography, in such a patient with a mechanical valve is mandatory.
Rothia mucilaginosa Prosthetic Device Infections: a Case of Prosthetic Valve Endocarditis
Tokarczyk, Mindy J.; Jungkind, Donald; DeSimone, Joseph A.
2013-01-01
Rothia mucilaginosa is increasingly recognized as an emerging opportunistic pathogen associated with prosthetic device infections. Infective endocarditis is one of the most common clinical presentations. We report a case of R. mucilaginosa prosthetic valve endocarditis and review the literature of prosthetic device infections caused by this organism. PMID:23467598
Nitta, S; Yambe, T; Katahira, Y; Sonobe, T; Saijoh, Y; Naganuma, S; Akiho, H; Kakinuma, Y; Tanaka, M; Miura, M
1991-12-01
To evaluate the various basic designs of the pump chambers used in the ventricular assist devices (VADs), hydrodynamic endurance test was performed from the viewpoint of the durability of the prosthetic valves used in the VAD. For the hydrodynamic analysis, we designed three basic types of pump (sac type, diaphragm type, and pusher plate type) using the same material and having the same capacity and shape. Prosthetic valves in these VADs were tested from the standpoint of the water hammer effect, which affects the valve durability, to determine which pump design would be most durable as a prosthetic valve in the VAD. The water-hammer phenomenon was evaluated using the maximum pressure gradient (MPG) across the prosthetic valve in the moc circulatory loop. Maximum pump output was recorded when we used the diaphragm type model, and minimum MPG in the commonly used driving condition of the VAD were recorded when we used the sac type model. The results suggest that the sac type VAD model is the most durable design for the prosthetic value.
Arnáiz-García, María Elena; González-Santos, Jose María; Bueno-Codoñer, María E; López-Rodríguez, Javier; Dalmau-Sorlí, María José; Arévalo-Abascal, Adolfo; Arribas-Jiménez, Antonio; Diego-Nieto, Alejandro; Rodríguez-Collado, Javier; Rodríguez-López, Jose María
2015-02-01
A 78-year-old woman was admitted to our institution with progressive dyspnea. She had previously been diagnosed with rheumatic heart disease and had undergone cardiac surgery for mechanical mitral valve replacement ten years previously. Transesophageal echocardiography revealed blockage of the mechanical prosthesis and the patient was scheduled for surgery, in which a thrombus was removed from the left atrial appendage. A partial thrombosis of the mechanical prosthesis and circumferential pannus overgrowth were concomitantly detected. Prosthetic heart valve blockage is a rare but life-threatening complication, the main causes of which are thrombosis and pannus formation. The two conditions are different but both are usually misdiagnosed. Two concurrent mechanisms of prosthesis blockage were found in this patient. Copyright © 2014 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.
Shimbo, Mai; Watanabe, Hiroyuki; Kimura, Shunsuke; Terada, Mai; Iino, Takako; Iino, Kenji; Ito, Hiroshi
2015-01-01
Real-time three-dimensional transesophageal echocardiography (RT3D-TEE) can provide unique visualization and better understanding of the relationship among cardiac structures. Here, we report the case of an 85-year-old woman with an obstructed mitral prosthetic valve diagnosed promptly by RT3D-TEE, which clearly showed a leaflet stuck in the closed position. The opening and closing angles of the valve leaflets measured by RT3D-TEE were compatible with those measured by fluoroscopy. Moreover, RT3D-TEE revealed, in the ring of the prosthetic valve, thrombi that were not visible on fluoroscopy. RT3D-TEE might be a valuable diagnostic technique for prosthetic mitral valve thrombosis. © 2014 Wiley Periodicals, Inc.
Mvondo, Charles Mve; Pugliese, Marta; Giamberti, Alessandro; Chelo, David; Kuate, Liliane Mfeukeu; Boombhi, Jerome; Dailor, Ellen Marie
2016-01-01
Rheumatic valve disease, a consequence of acute rheumatic fever, remains endemic in developing countries in the sub-Saharan region where it is the leading cause of heart failure and cardiovascular death, involving predominantly a young population. The involvement of the mitral valve is pathognomonic and mitral surgery has become the lone therapeutic option for the majority of these patients. However, controversies exist on the choice between valve repair or prosthetic valve replacement. Although the advantages of mitral valve repair over prosthetic valve replacement in degenerative mitral disease are well established, this has not been the case for rheumatic lesions, where the use of prosthetic valves, specifically mechanical devices, even in poorly compliant populations remains very common. These patients deserve more accurate evaluation in the choice of the surgical strategy which strongly impacts the post-operative outcomes. This report discusses the factors supporting mitral repair surgery in rheumatic disease, according to the patients' characteristics and the effectiveness of the current repair techniques compared to prosthetic valve replacement in developing countries.
Molecular Identification of Human Fungal Pathogens
2008-03-01
reported this period: Drees M, Wickes BL, Gupta M, Hadley S. Lecythophora mutabilis prosthetic valve endocarditis in a diabetic patient. Med Mycol. (2007...Wickes BL, Gupta M, Hadley S. 2007. Lecythophora mutabilis prosthetic valve endocarditis in a diabetic patient. Med Mycol. 45:463-467. 9...information: http://www.informaworld.com/smpp/title~content=t713694156 Lecythophora mutabilis prosthetic valve endocarditis in a diabetic patient Marci
A new paradigm for obtaining marketing approval for pediatric-sized prosthetic heart valves.
Yoganathan, Ajit P; Fogel, Mark; Gamble, Susan; Morton, Michael; Schmidt, Paul; Secunda, Jeff; Vidmar, Sara; Del Nido, Pedro
2013-10-01
Congenital heart valve disease is one of the most common abnormalities in children. There are limited technological solutions available for treating children with congenital heart valve diseases. The aim of this study is to provide the details of the consensus reached in terms of pediatric definitions, design approach, in vitro testing, and clinical trials, which may be used as guidance for developing prosthetic heart valves for the pediatric indication. In stark contrast to the various designs of adult-sized replacement valves available in the market, there are no Food and Drug Administration (FDA)-approved prosthetic heart valves available for use in the pediatric population. There is a pressing need for FDA-approved pediatric valve devices in the United States. The pediatric patient population has been typically excluded from replacement heart valve trials for several reasons. In January 2010, heart valve manufacturers and pediatric clinicians collaborated with academicians and FDA staff in a workshop to suggest ways to successfully evaluate pediatric prosthetic valves and conduct pediatric clinical trials to provide acceptable heart valve replacement options for this patient population. Recommendations, derived from ISO 5840:2005 and the 2010 FDA Draft Replacement Heart Valve Guidance, are provided for hydrodynamic, durability, and fatigue testing. The article specifically addresses in vitro and premarket and postmarket approval clinical studies that should be considered by a heart valve manufacturer for obtaining regulatory approval of pediatric sizes of prosthetic heart valve designs that are already approved for adult clinical use. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Jung, Joonho; Lee, Cheol Joo; Lim, Sang-Hyun; Choi, Ho; Park, Soo-Jin
2013-01-01
A 51-year-old male was admitted to the hospital with complaints of fever and hemoptysis. After evaluation of the fever focus, he was diagnosed with pulmonary valve infective endocarditis. Thus pulmonary valve replacement and antibiotics therapy were performed and discharged. He was brought to the emergency unit presenting with a high fever (>39℃) and general weakness 6 months after the initial operation. The echocardiography revealed prosthetic pulmonary valve endocarditis. Therefore, redo-pulmonary valve replacement using valved conduit was performed in the Rastelli fashion because of the risk of pulmonary arterial wall injury and recurrent endocarditis from the remnant inflammatory tissue. We report here on the successful surgical treatment of prosthetic pulmonary valve endocarditis with an alternative surgical method. PMID:23772409
Suh, Young Joo; Lee, Sak; Im, Dong Jin; Chang, Suyon; Hong, Yoo Jin; Lee, Hye-Jeong; Hur, Jin; Choi, Byoung Wook; Chang, Byung-Chul; Shim, Chi Young; Hong, Geu-Ru; Kim, Young Jin
2016-07-01
The added value of cardiac computed tomography (CT) with transesophageal echocardiography (TEE) for evaluating mechanical aortic valve (AV) dysfunction has not yet been investigated. The purposes of this study were to investigate the added value of cardiac CT for evaluation of mechanical AVs and diagnoses of pannus compared to TEE, with surgical findings of redo-aortic valve replacement (AVR) used as a standard reference. 25 patients who underwent redo-AVR due to mechanical AV dysfunction and cardiac CT before redo-AVR were included. The presence of pannus, encroachment ratio by pannus, and limitation of motion (LOM) were evaluated on CT. The diagnostic performance of pannus detection was compared using TEE, CT, and CT+TEE, with surgical findings as a standard reference. The added value of CT for diagnosing the cause of mechanical AV dysfunction was assessed compared to TTE+TEE. In two patients, CT analysis was not feasible due to severe metallic artifacts. On CT, pannus and LOM were found in 100% (23/23) and 60.9% (14/23). TEE identified pannus in 48.0% of patients (12/25). CT, TEE, and CT+TEE correctly identified pannus with sensitivity of 92.0%, 48.0%, and 92.0%, respectively (P=0.002 for CT vs. TEE). In 11 of 13 cases (84.6%) with inconclusive or negative TEE results for pannus, CT detected the pannus. Among 13 inconclusive cases of TTE+TEE for the cause of mechanical AV dysfunction, CT suggested 6 prosthetic valve obstruction (PVO) by pannus, 4 low-flow low-gradient PVO, and one LOM without significant PVO. Cardiac CT showed added diagnostic value with TEE in the detection of pannus as the cause of mechanical AV dysfunction. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Kawahito, Tomohisa; Egawa, Yoshiyasu; Yoshida, Homare; Shimoe, Yasushi; Onishi, Tatsuya; Miyagi, Yuhichi; Terada, Kazuya; Ohta, Akira
2015-07-01
A 24-day-old boy suddenly developed progressive heart failure and was transported to our hospital. Echocardiography showed massive mitral regurgitation due to chordal rupture. Mitral valve repair was performed at 28 days of life, but postoperative valvular function was not satisfactory. A mechanical valve was implanted in the supra-annular position at 37 days of life. Two months after valve replacement, the mechanical valve was suddenly stuck. Emergent redo valve replacement was performed, but the prosthetic valve became stuck again 2 months after the 3rd operation, despite sufficient anti-coagulation therapy. At the 4th operation (6 months after birth), we implanted a pulmonary autograft in the mitral position instead of another mechanical valve in an emergent operation. The right ventricular outflow tract was reconstructed with a valved conduit. A postoperative catheter examination, which was performed 1 year after the Ross II operation, showed mild mitral stenosis with no regurgitation. Previous reports of Ross II operations in infants are rare and long-term results are unknown. However, we advocate that this procedure should be a rescue operation for mitral valve dysfunction in the early period of infants.
Tauras, James M; Zhang, Zhihang; Taub, Cynthia C
2011-05-01
A young woman with a mechanical mitral valve and prosthetic mitral stenosis underwent multiple imaging modalities (including transthoracic ECHO, fluoroscopy, and two-dimensional transesophageal ECHO) to determine the cause of her stenosis. Only three-dimensional transesophageal echocardiography demonstrated the full size and extent of an obstructing mass on the strut and sewing ring of the prosthetic mitral valve. © 2011, Wiley Periodicals, Inc.
Capnocytophaga canimorsus: a rare case of conservatively treated prosthetic valve endocarditis.
Jalava-Karvinen, Päivi; Grönroos, Juha O; Tuunanen, Helena; Kemppainen, Jukka; Oksi, Jarmo; Hohenthal, Ulla
2018-05-01
We describe a rare case of prosthetic valve endocarditis caused by the canine bacterium Capnocytophaga canimorsus in a male aged 73 years. The diagnosis of infective endocarditis was unequivocal, as it blood cultures were positive for C. canimorsus and vegetations were detected on transesophageal echocardiography; the modified Duke criteria were fulfilled. PET-CT showed intense 18 F-FDG uptake of the prosthetic valve area. The patient was treated with antibiotics alone (no surgery), and is now on life-long suppressive antibiotic therapy. To our knowledge, this is the third reported case of prosthetic valve endocarditis caused by C. canimorsus and the first one to have been treated conservatively. © 2018 APMIS. Published by John Wiley & Sons Ltd.
Bartley, Patricia; Angelakis, Emmanouil; Raoult, Didier; Sampath, Rangarajan; Bonomo, Robert A.
2016-01-01
Identifying the pathogen responsible for culture-negative valve endocarditis often depends on molecular studies performed on surgical specimens. A patient with Ehlers-Danlos syndrome who had an aortic graft, a mechanical aortic valve, and a mitral anulloplasty ring presented with culture-negative prosthetic valve endocarditis and aortic graft infection. Research-based polymerase chain reaction (PCR)/electrospray ionization mass spectrometry on peripheral blood samples identified Bartonella henselae. Quantitative PCR targeting the16S-23S ribonucleic acid intergenic region and Western immunoblotting confirmed this result. This, in turn, permitted early initiation of pathogen-directed therapy and subsequent successful medical management of B henselae prosthetic valve endocarditis and aortic graft infection. PMID:27844027
Schoonbeek, R C; Pieper, P G; van Slooten, Y J; Freling, H G; Sieswerda, G T; van Dijk, A P J; Jongbloed, M R M; Post, M C; Bouma, B J; Berger, R M F; Ebels, T; van Melle, J P
2016-11-01
N-terminal B‑type natriuretic peptide (NT-proBNP) is an important biomarker for the detection of heart failure. Adults with congenital heart disease (ACHD) and a prosthetic heart valve are at risk for heart failure. This study aimed to determine the value of NT-proBNP in ACHD patients with a prosthetic valve and investigate its relationship with cardiac function and exercise capacity. In this multi-centre cross-sectional observational study, data regarding medical history, echocardiography, exercise testing (VO 2 peak) and laboratory blood evaluation (including NT-proBNP) were collected in ACHD patients with a single prosthetic valve (either homografts, heterografts or mechanical valves). A total of 306 ACHD patients with pulmonary valve replacement (PVR, n = 139), aortic valve replacement (n = 141), mitral valve replacement (n = 21) or tricuspid valve replacement (n = 5) were investigated. The majority of patients (77 %) were in NYHA class I or II. Elevated NT-proBNP levels (cut-off ≥125 pg/ml) were found in 50 % of the patients, with the highest levels in patients with mitral valve replacements. In this study population, NT-proBNP levels were associated with gender (p = 0.029) and VO 2 max (p < 0.001). In PVR patients, NT-proBNP levels were associated with lower VO 2 peak, also after adjustment for age, gender and age at valve replacement in a multivariate model (p = 0.015). In patients with ACHD and a prosthetic valve, elevated NT-proBNP levels are frequently observed despite preserved NYHA class. In PVR patients, a higher NT-proBNP level was associated with a lower VO 2 peak. These results may be of importance in the ongoing discussion about the timing of valve replacement in patients with CHD.
Thirty-Seven-Year Durability of a Starr-Edwards Aortic Prosthesis
Ozkokeli, Mehmet; Ates, Mehmet; Ekinci, Abdurrahman; Akcar, Murat
2005-01-01
We report the case of a patient who was diagnosed with prosthetic valve endocarditis caused by Staphylococcus aureus. He had undergone aortic valve replacement with a Starr-Edwards prosthesis 37 years earlier. Because of uncontrolled infection despite antibiotic treatment, the patient underwent successful surgical replacement of the prosthetic valve. PMID:15902834
NASA Technical Reports Server (NTRS)
Helms, C. R.; Smyly, H. M. (Inventor)
1981-01-01
A pump/valve unit for controlling the inflation and deflation of a urethral collar in a prosthetic urinary sphincter device is described. A compressible bulb pump defining a reservoir was integrated with a valve unit for implantation. The valve unit includes a movable valve member operable by depression of a flexible portion of the valve unit housing for controlling fluid flow between the reservoir and collar; and a pressure sensing means which operates the valve member to relieve an excess pressure in the collar should too much pressure be applied by the patient.
Riki-Marishani, Mohsen; Gholoobi, Arash; Sazegar, Ghasem; Aazami, Mathias H; Hedjazi, Aria; Sajjadian, Maryam; Ebrahimi, Mahmoud; Aghaii-Zade Torabi, Ahmad
2017-09-01
A prosthetic system to repair secondary tricuspid valve regurgitation was developed. The conceptual engineering of the current device is based on 3D segmental remodelling of the tricuspid valve annulus in lieu of reductive annuloplasty. This study was designed to investigate the operational safety of the current prosthetic system with regard to the anatomical integrity of the right coronary artery (RCA) in fresh cadaveric human hearts. During the study period, from January to April 2016, the current prosthetic system was implanted on the tricuspid valve annulus in fresh cadaveric human hearts that met the study's inclusion criteria. The prepared specimens were investigated via selective coronary angiography of the RCA in the catheterization laboratory. The RCA angiographic anatomies were categorized as normal, distorted, kinked or occluded. Sixteen specimens underwent implantation of the current prosthetic system. The mean age of the cadaveric human hearts was 43.24 ± 15.79 years, with vehicle accident being the primary cause of death (59%). A dominant RCA was noticed in 62.5% of the specimens. None of the specimens displayed any injury, distortion, kinking or occlusion in the RCA due to the implantation of the prostheses. In light of the results of the present study, undertaken on fresh cadaveric human heart specimens, the current segmental prosthetic system for 3D remodelling of the tricuspid valve annulus seems to be safe vis-à-vis the anatomical integrity of the RCA. Further in vivo studies are needed to investigate the functional features of the current prosthetic system with a view to addressing the complex pathophysiology of secondary tricuspid valve regurgitation. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Early Transcatheter Aortic Valve Function With and Without Therapeutic Anticoagulation.
Hiremath, Pranoti G; Kearney, Kathleen; Smith, Bryn; Don, Creighton; Dvir, Danny; Aldea, Gabriel; Reisman, Mark; McCabe, James M
2017-11-01
Prosthetic leaflet thrombosis is a growing concern in transcatheter aortic valve replacement (TAVR). Given the uncertainty of best practices for antiplatelet and anticoagulation therapies in the post-TAVR period, additional evidence regarding the impact of anticoagulation on prosthetic valve function after TAVR is needed. Patients undergoing native-valve TAVR at a single academic institution between 2012 and 2015 were analyzed based on any anticoagulant use at hospital discharge post TAVR. Changes in prosthetic valve peak velocity and mean gradient were assessed based on transthoracic echocardiograms performed immediately following valve implant and at 4-week follow-up. Multivariate regression analyses were performed to explore the impact of anticoagulation status on early TAVR valve performance. For 403 patients, there were no available data to analyze. Of those, 29.6% were discharged on anticoagulation. Following TAVR, the average mean prosthetic valve gradient was 11.8 ± 5.6 mm Hg and peak velocity was 2.33 ± 0.52 m/s. There were no significant differences between anticoagulated and non-anticoagulated groups in the mean or peak gradients or velocity immediately following implant or at 4 weeks, which remained true following multivariate adjustment (P=.80 for delta mean gradient; P=.91 for delta peak velocity). Our data suggest that the absence of anticoagulation is not associated with short-term degradation in TAVR performance and do not support the routine use of anticoagulation following native-valve TAVR.
Korteland, Nelleke M; Ahmed, Yunus; Koolbergen, David R; Brouwer, Marjan; de Heer, Frederiek; Kluin, Jolanda; Bruggemans, Eline F; Klautz, Robert J M; Stiggelbout, Anne M; Bucx, Jeroen J J; Roos-Hesselink, Jolien W; Polak, Peter; Markou, Thanasie; van den Broek, Inge; Ligthart, Rene; Bogers, Ad J J C; Takkenberg, Johanna J M
2017-02-01
A Dutch online patient decision aid to support prosthetic heart valve selection was recently developed. A multicenter randomized controlled trial was conducted to assess whether use of the patient decision aid results in optimization of shared decision making in prosthetic heart valve selection. In a 5-center randomized controlled trial, patients were allocated to receive either standard preoperative care (control group) or additional access to the patient decision aid (intervention group). Legally capable adult patients accepted for elective isolated or combined aortic and mitral valve replacement were included. Primary outcome was preoperative decisional conflict (Decisional Conflict Scale); secondary outcomes included patient knowledge, involvement in valve selection, anxiety and depression, (valve-specific) quality of life, and regret. Out of 306 eligible patients, 155 were randomized (78 control and 77 intervention). Preoperative decisional conflict did not differ between the groups (34% versus 33%; P =0.834). Intervention patients felt better informed (median Decisional Conflict Scale informed subscore: 8 versus 17; P =0.046) and had a better knowledge of prosthetic valves (85% versus 68%; P =0.004). Intervention patients experienced less anxiety and depression (median Hospital Anxiety and Depression Scale score: 6 versus 9; P =0.015) and better mental well-being (mean Short Form Health Survey score: 54 versus 50; P =0.032). Three months postoperatively, valve-specific quality of life and regret did not differ between the groups. A patient decision aid to support shared decision making in prosthetic heart valve selection does not lower decisional conflict. It does result in more knowledgeable, better informed, and less anxious and depressed patients, with a better mental well-being. http://www.trialregister.nl. Unique identifier: NTR4350. © 2017 American Heart Association, Inc.
Amraoui, Sana; Tlili, Ghoufrane; Sohal, Manav; Bordenave, Laurence; Bordachar, Pierre
2016-12-01
18-Fluorodeoxyglucose positron emission tomography/computerized tomography (FDG PET/CT) scanning has recently been proposed as a diagnostic tool for lead endocarditis (LE). FDG PET/CT might be also useful to localize associated septic emboli in patients with LE. We report an interesting case of a LE patient with a prosthetic aortic valve in whom a trans-esophageal echocardiogram did not show associated aortic endocarditis. FDG PET/CT revealed prosthetic aortic valve infection. A second TEE performed 2 weeks after identified aortic vegetation. A longer duration of antimicrobial therapy with serial follow-up echocardiography was initiated. There was also increased uptake in the sigmoid colon, corresponding to focal polyps resected during a colonoscopy. FDG PET/CT scanning seems to be highly sensitive for prosthetic aortic valve endocarditis diagnosis. This promising diagnostic tool may be beneficial in LE patients, by identifying septic emboli and potential sites of pathogen entry.
NASA Technical Reports Server (NTRS)
Lin, S. S.; Tiong, I. Y.; Asher, C. R.; Murphy, M. T.; Thomas, J. D.; Griffin, B. P.
2000-01-01
Identification of thrombus-related mechanical prosthetic valve dysfunction (MPVD) has important therapeutic implications. We sought to develop an algorithm, combining clinical and echocardiographic parameters, for prediction of thrombus-related MPVD in a series of 53 patients (24 men, age 52 +/- 16 years) who had intraoperative diagnosis of thrombus or pannus from 1992 to 1997. Clinical and echocardiographic parameters were analyzed to identify predictors of thrombus and pannus. Prevalence of thrombus and diagnostic yields relative to the number of predictors were determined. There were 22 patients with thrombus, 19 patients with pannus, and 12 patients with both. Forty-two of 53 masses were visualized using transesophageal echocardiography (TEE), including 29 of 34 thrombi or both thrombi and panni and 13 of 19 isolated panni. Predictors of thrombus or mixed presentation include mobile mass (p = 0.009), attachment to occluder (p = 0.02), elevated gradients (p = 0.04), and an international normalized ratio of < or = 2.5 (p = 0.03). All 34 patients with thrombus or mixed presentation had > or = 1 predictor. The prevalence of thrombus in the presence of < or = 1, 2, and > or = 3 predictors is 14%, 69%, and 91%, respectively. Thus, TEE is sensitive in the identification of abnormal mass in the setting of MPVD. An algorithm based on clinical and transesophageal echocardiographic predictors may be useful to estimate the likelihood of thrombus in the setting of MPVD. In the presence of > or = 3 predictors, the probability of thrombus is high.
Faure, Marguerite E; Swart, Laurens E; Dijkshoorn, Marcel L; Bekkers, Jos A; van Straten, Marcel; Nieman, Koen; Parizel, Paul M; Krestin, Gabriel P; Budde, Ricardo P J
2018-05-01
Multidetector CT (MDCT) is a valuable tool for functional prosthetic heart valve (PHV) assessment. However, radiation exposure remains a concern. We assessed a novel CT-acquisition protocol for comprehensive PHV evaluation at limited dose. Patients with a PHV were scanned using a third-generation dual-source CT scanner (DSCT) and iterative reconstruction technique (IR). Three acquisitions were obtained: a non-enhanced scan; a contrast-enhanced, ECG-triggered, arterial CT angiography (CTA) scan with reconstructions at each 5 % of the R-R interval; and a delayed high-pitch CTA of the entire chest. Image quality was scored on a five-point scale. Radiation dose was obtained from the reported CT dose index (CTDI) and dose length product (DLP). We analysed 43 CT examinations. Mean image quality score was 4.1±1.4, 4.7±0.5 and 4.2±0.6 for the non-contrast-enhanced, arterial and delayed acquisitions, respectively, with a total mean image quality of 4.3±0.7. Mean image quality for leaflet motion was 3.9±1.4. Mean DLP was 28.2±17.1, 457.3±168.6 and 68.5±47.2 mGy.cm for the non-contrast-enhanced (n=40), arterial (n=43) and delayed acquisition (n=43), respectively. The mean total DLP was 569±208 mGy.cm and mean total radiation dose was 8.3±3.0 mSv (n=43). Comprehensive assessment of PHVs is possible using DSCT and IR at moderate radiation dose. • Prosthetic heart valve dysfunction is a potentially life-threatening condition. • Dual-source CT can adequately assess valve leaflet motion and anatomy. • We assessed a comprehensive protocol with three acquisitions for PHV evaluation. • This protocol is associated with good image quality and limited dose.
Surgery Versus Transcatheter Interventions for Significant Paravalvular Prosthetic Leaks.
Millán, Xavier; Bouhout, Ismail; Nozza, Anna; Samman, Karla; Stevens, Louis-Mathieu; Lamarche, Yoan; Serra, Antonio; Asgar, Anita W; El-Hamamsy, Ismail; Cartier, Raymond; Pellerin, Michel; Noble, Stephane; Demers, Phillipe; Ibrahim, Reda; Jolicœur, E Marc; Bouchard, Denis
2017-10-09
This study sought to assess the relative merit of surgical correction (SC) versus transcatheter reduction on long-term outcomes in patients with significant paravalvular leak (PVL) refractory to medical therapy. PVL is the most frequent dysfunction following prosthetic valve replacement. Although repeat surgery is the gold standard, transcatheter reduction (TR) of PVL has been associated with reduced mortality. From 1994 to 2014, 231 patients underwent SC (n = 151) or TR (n = 80) PVL correction. Propensity matching and Cox proportional hazards regression models were used to assess the effect of either intervention on long-term rates of all-cause death or hospitalization for heart failure. Survival after TR and SC were further compared with the survival in a matched general population and to matched patients undergoing their first surgical valve replacement. Over a median follow-up of 3.5 years, SC was associated with an important reduction in all-cause death or hospitalization for heart failure compared with TR (hazard ratio: 0.28; 95% confidence interval: 0.18 to 0.44; p < 0.001). There was a trend towards reduced all-cause death following SC versus TR (hazard ratio: 0.61; 95% confidence interval: 0.37 to 1.02; p = 0.06). Neither intervention normalized survival when compared with a general population or patients undergoing their first surgical valve replacement. In patients with significant prosthetic PVL, surgery is associated with better long-term outcomes compared with transcatheter intervention, but results in important perioperative mortality and morbidity. Future studies are needed in the face of increasing implementation of transcatheter PVL interventions across the world. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Tao, Ende; Wan, Li; Wang, WenJun; Luo, YunLong; Zeng, JinFu; Wu, Xia
2017-01-01
Surgery remains the primary form of treatment for infective endocarditis (IE). However, it is not clear what type of prosthetic valve provides a better prognosis. We conducted a meta-analysis to compare the prognosis of infective endocarditis treated with biological valves to cases treated with mechanical valves. Pubmed, Embase and Cochrane databases were searched from January 1960 to November 2016.Randomized controlled trials, retrospective cohorts and prospective studies comparing outcomes between biological valve and mechanical valve management for infective endocarditis were analyzed. The Newcastle-Ottawa Scale(NOS) was used to evaluate the quality of the literature and extracted data, and Stata 12.0 software was used for the meta-analysis. A total of 11 publications were included; 10,754 cases were selected, involving 6776 cases of biological valves and 3,978 cases of mechanical valves. The all-cause mortality risk of the biological valve group was higher than that of the mechanical valve group (HR = 1.22, 95% CI 1.03 to 1.44, P = 0.023), as was early mortality (RR = 1.21, 95% CI 1.02 to 1.43, P = 0.033). The recurrence of endocarditis (HR = 1.75, 95% CI 1.26 to 2.42, P = 0.001), as well as the risk of reoperation (HR = 1.79, 95% CI 1.15 to 2.80, P = 0.010) were more likely to occur in the biological valve group. The incidence of postoperative embolism was less in the biological valve group than in the mechanical valve group, but this difference was not statistically significant (RR = 0.90, 95% CI 0.76 to 1.07, P = 0.245). For patients with prosthetic valve endocarditis (PVE), there was no significant difference in survival rates between the biological valve group and the mechanical valve group (HR = 0.91, 95% CI 0.68 to 1.21, P = 0.520). The results of our meta-analysis suggest that mechanical valves can provide a significantly better prognosis in patients with infective endocarditis. There were significant differences in the clinical features of patients receiving a biological valve compared to patients receiving a mechanical valve. A large, multicenter retrospective study included in our meta-analysis suggested that any mortality risk of the biological valve group was significant higher than that of the mechanical valve group. However, the risk was no different after risk was adjusted. So, we thought the reason for this result may be related to the characteristics of the patient rather than valve dysfunction. It is still necessary to future randomized studies to verify this conclusion.
Topography of aortic heart valves. [applied to the development of a prosthetic heart valve
NASA Technical Reports Server (NTRS)
Karara, H. M.
1974-01-01
The cooperative effort towards the development of a tri-leaflet prosthetic heart valve is described. The photogrammetric studies were conducted on silicone rubber molds. Information on data acquisition and data reduction phases is given, and certain accuracy aspects of the project are explained. The various outputs which are discussed include digital models, profiles, and contour maps.
McNeely, Christian A; Vassileva, Christina M
2015-01-01
The short-term advantage of mitral valve repair versus replacement for degenerative disease has been extensively documented. These advantages include lower operative mortality, improved survival, better preservation of left-ventricular function, shorter post-operative hospital stay, lower total costs, and fewer valve-related complications, including thromboembolism, anticoagulation-related bleeding events and late prosthetic dysfunction. More recent written data are available indicating the long-term advantage of repair versus replacement. While at some institutions, the repair rate for degenerative disease may exceed 90%, the national average in 2007 was only 69%. Making direct comparisons between mitral valve repair and replacement using the available studies does present some challenges however, as there are often differences in baseline characteristics between patient groups as well as other dissimilarities between studies. The purpose of this review is to systematically summarize the long-term survival and reoperation data of mitral valve repair versus replacement for degenerative disease. A PubMed search was done and resulted in 12 studies that met our study criteria for comparing mitral valve repair versus replacement for degenerative disease. A systematic review was then conducted abstracting survival and reoperation data. PMID:25158683
A rare case of prosthetic endocarditis and dehiscence in a mechanical valved conduit
Kannan, Arun; Smith, Cristy; Subramanian, Sreekumar; Janardhanan, Rajesh
2014-01-01
A middle-aged adult patient with a history of aortic root replacement with a mechanical valved conduit and remote chest trauma was referred to our institution with prosthetic endocarditis. Transoesophageal echocardiogram at our institution confirmed a near-complete dehiscence of the prosthetic aortic valve from the conduit, with significant perivalvular flow forming a pseudoaneurysm. The patient underwent a high-risk re-operation, involving redo aortic root replacement with a homograft after extensive debridement of the infected tissue. The patient was discharged to an outside facility after an uncomplicated hospital course, and remains stable. PMID:24510692
A rare case of prosthetic endocarditis and dehiscence in a mechanical valved conduit.
Kannan, Arun; Smith, Cristy; Subramanian, Sreekumar; Janardhanan, Rajesh
2014-02-07
A middle-aged adult patient with a history of aortic root replacement with a mechanical valved conduit and remote chest trauma was referred to our institution with prosthetic endocarditis. Transoesophageal echocardiogram at our institution confirmed a near-complete dehiscence of the prosthetic aortic valve from the conduit, with significant perivalvular flow forming a pseudoaneurysm. The patient underwent a high-risk re-operation, involving redo aortic root replacement with a homograft after extensive debridement of the infected tissue. The patient was discharged to an outside facility after an uncomplicated hospital course, and remains stable.
Evaluation of mitral valve replacement anchoring in a phantom
NASA Astrophysics Data System (ADS)
McLeod, A. Jonathan; Moore, John; Lang, Pencilla; Bainbridge, Dan; Campbell, Gordon; Jones, Doug L.; Guiraudon, Gerard M.; Peters, Terry M.
2012-02-01
Conventional mitral valve replacement requires a median sternotomy and cardio-pulmonary bypass with aortic crossclamping and is associated with significant mortality and morbidity which could be reduced by performing the procedure off-pump. Replacing the mitral valve in the closed, off-pump, beating heart requires extensive development and validation of surgical and imaging techniques. Image guidance systems and surgical access for off-pump mitral valve replacement have been previously developed, allowing the prosthetic valve to be safely introduced into the left atrium and inserted into the mitral annulus. The major remaining challenge is to design a method of securely anchoring the prosthetic valve inside the beating heart. The development of anchoring techniques has been hampered by the expense and difficulty in conducting large animal studies. In this paper, we demonstrate how prosthetic valve anchoring may be evaluated in a dynamic phantom. The phantom provides a consistent testing environment where pressure measurements and Doppler ultrasound can be used to monitor and assess the valve anchoring procedures, detecting pararvalvular leak when valve anchoring is inadequate. Minimally invasive anchoring techniques may be directly compared to the current gold standard of valves sutured under direct vision, providing a useful tool for the validation of new surgical instruments.
Wagner, Martin G; Hatt, Charles R; Dunkerley, David A P; Bodart, Lindsay E; Raval, Amish N; Speidel, Michael A
2018-04-16
Transcatheter aortic valve replacement (TAVR) is a minimally invasive procedure in which a prosthetic heart valve is placed and expanded within a defective aortic valve. The device placement is commonly performed using two-dimensional (2D) fluoroscopic imaging. Within this work, we propose a novel technique to track the motion and deformation of the prosthetic valve in three dimensions based on biplane fluoroscopic image sequences. The tracking approach uses a parameterized point cloud model of the valve stent which can undergo rigid three-dimensional (3D) transformation and different modes of expansion. Rigid elements of the model are individually rotated and translated in three dimensions to approximate the motions of the stent. Tracking is performed using an iterative 2D-3D registration procedure which estimates the model parameters by minimizing the mean-squared image values at the positions of the forward-projected model points. Additionally, an initialization technique is proposed, which locates clusters of salient features to determine the initial position and orientation of the model. The proposed algorithms were evaluated based on simulations using a digital 4D CT phantom as well as experimentally acquired images of a prosthetic valve inside a chest phantom with anatomical background features. The target registration error was 0.12 ± 0.04 mm in the simulations and 0.64 ± 0.09 mm in the experimental data. The proposed algorithm could be used to generate 3D visualization of the prosthetic valve from two projections. In combination with soft-tissue sensitive-imaging techniques like transesophageal echocardiography, this technique could enable 3D image guidance during TAVR procedures. © 2018 American Association of Physicists in Medicine.
Sugeng, Lissa; Shernan, Stanton K; Weinert, Lynn; Shook, Doug; Raman, Jai; Jeevanandam, Valluvan; DuPont, Frank; Fox, John; Mor-Avi, Victor; Lang, Roberto M
2008-12-01
Recently, a novel real-time 3-dimensional (3D) matrix-array transesophageal echocardiographic (3D-MTEE) probe was found to be highly effective in the evaluation of native mitral valves (MVs) and other intracardiac structures, including the interatrial septum and left atrial appendage. However, the ability to visualize prosthetic valves using this transducer has not been evaluated. Moreover, the diagnostic accuracy of this new technology has never been validated against surgical findings. This study was designed to (1) assess the quality of 3D-MTEE images of prosthetic valves and (2) determine the potential value of 3D-MTEE imaging in the preoperative assessment of valvular pathology by comparing images with surgical findings. Eighty-seven patients undergoing clinically indicated transesophageal echocardiography were studied. In 40 patients, 3D-MTEE images of prosthetic MVs, aortic valves (AVs), and tricuspid valves (TVs) were scored for the quality of visualization. For both MVs and AVs, mechanical and bioprosthetic valves, the rings and leaflets were scored individually. In 47 additional patients, intraoperative 3D-MTEE diagnoses of MV pathology obtained before initiating cardiopulmonary bypass were compared with surgical findings. For the visualization of prosthetic MVs and annuloplasty rings, quality was superior compared with AV and TV prostheses. In addition, 3D-MTEE imaging had 96% agreement with surgical findings. Three-dimensional matrix-array transesophageal echocardiographic imaging provides superb imaging and accurate presurgical evaluation of native MV pathology and prostheses. However, the current technology is less accurate for the clinical assessment of AVs and TVs. Fast acquisition and immediate online display will make this the modality of choice for MV surgical planning and postsurgical follow-up.
Optimal surgical management of severe tricuspid regurgitation in cardiac transplant patients.
Filsoufi, Farzan; Salzberg, Sacha P; Anderson, Curtis A; Couper, Gregory S; Cohn, Lawrence H; Adams, David H
2006-03-01
Severe tricuspid regurgitation (TR) with signs of right-sided heart failure is rare after orthotopic heart transplantation (OHT). In some instances, this condition will require surgical correction using reconstructive surgery or prosthetic valve replacement. Repair techniques of atrioventricular valves are now well described. However, the results of the different surgical procedures in this setting have not been widely reported and may depend on the type of valvular dysfunction and lesions present. Herein we report our experience in a group of patients requiring surgical correction of symptomatic severe TR after OHT. We reviewed our transplant experience during the period from July 1992 to July 1999 (n = 138 cardiac transplants). Eight patients (5.8%) developed symptomatic severe TR requiring surgical correction after a mean duration of 21 months after OHT. Patients were divided into 2 groups based on the mechanism of regurgitation using Carpentier's functional classification. In Group 1 (n = 4), the mechanism of tricuspid regurgitation was Carpentier's Type I, secondary to annular dilation. In Group 2 (n = 4) the mechanism of TR was leaflet prolapse (Type II), due to chordal rupture after biopsy injury. Initially, tricuspid valve integrity was surgically restored in all 8 patients with either valve repair (n = 6) or replacement (n = 2). In Group 1, 2 patients underwent valve repair using a ring annuloplasty and 2 patients underwent valve replacement with a bioprosthetic valve (n = 1) or pulmonary allograft (n = 1). In Group 2, all patients underwent valve repair using a variety of techniques in combination with tricuspid annuloplasty. During the follow-up period, 3 of the 6 (50%) primary repairs (1 patient in Group 1 and 2 in Group 2) failed and required replacement with a bioprosthesis at 8 days, 14 days and 4 years, respectively. The pulmonary allograft failed secondary to valvular stenosis and was replaced with a bioprosthesis after 10 months. Overall, no failures occurred in any of the 5 bioprosthetic valves placed at the primary operation (n = 1) or after failed tricuspid repair/pulmonary allograft (n = 4), after a mean follow-up of 55 months. TR requiring surgical correction after OHT is a rare condition and requires a tailored surgical strategy. This strategy should take into account the mechanism of valve dysfunction and specific valvular lesions. In patients with Type I dysfunction secondary to annular dilation, valve repair with a remodeling annuloplasty should be performed; however, in the presence of any residual TR on transesophageal echocardiography (TEE) at the completion of cardiopulmonary bypass (CPB), a valve replacement with a bioprosthesis is warranted during the same procedure. In patients with Type II dysfunction with leaflet prolapse and biopsy-induced chordal injury, a bioprosthetic valve replacement seems a reliable surgical option.
Is Fasting for Ramadan Safe in Patients with Mechanical Cardiac Valves?
Yildirim, Ersin; Secen, Ozlem; Uku, Okkes; Nail Bilen, Mehmet; Kutlu Karadag, Makbule
2017-03-01
The study aim was to investigate the safety and effects of fasting during Ramadan on the International Normalized Ratio (INR) in patients with mechanical cardiac valves. A total of 105 patients admitted to the authors' hospital between June and October 2015, who had history of prosthetic valve replacement, was investigated. The patients were allocated to two groups: those fasting during Ramadan (n = 42) and those not fasting (n = 63). All patients were examined by a cardiologist, and the clinical findings and complaints for the past three months were evaluated. The INR, complete blood count (CBC) and a basic biochemical panel were monitored for all patients. The mean corpuscular volume (MCV) of the fasting group was significantly higher than that of the non- fasting group (87.59 ± 6.39 (μm3) versus 84.28 ± 6.387 (μm3); p = 0.011). Other CBC parameters and basic biochemical values did not differ significantly different between groups. Neither were significant differences noted in INR values during Ramadan (fasting group 2.87 ± 0.97; non-fasting group 2.73 ± 0.78; p = 0.50) and at routine control one month later (fasting group 3.07 ± 1.55; non-fasting group 2.94 ± 1.03; p = 0.601). No significant differences related to increased rates of hospitalization, valvular dysfunction on echocardiography, thrombus, embolism, bleeding and clinical complaints were identified between the groups. Fasting during Ramadan had no adverse effects on the INR of patients, and appears to be safe for patients with mechanical prosthetic cardiac valves.
Sarı, Cenk; Durmaz, Tahir; Karaduman, Bilge Duran; Keleş, Telat; Bayram, Hüseyin; Baştuğ, Serdal; Özen, Mehmet Burak; Bayram, Nihal Akar; Bilen, Emine; Ayhan, Hüseyin; Kasapkara, Hacı Ahmet; Bozkurt, Engin
2016-01-01
Transcatheter aortic valve implantation (TAVI) was introduced as an alternative treatment for patients with severe symptomatic aortic stenosis for whom surgery would be high-risk. Prosthetic aortic valve endocarditis is a serious complication of surgical AVR (SAVR) with high morbidity and mortality. According to recent cases, post-TAVI prosthetic valve endocarditis (PVE) seems to occur very rarely. We present the case of a 75-year-old woman who underwent TAVI (Edwards Saphien XT) with an uneventful postoperative stay. She was diagnosed with endocarditis using three dimensional (3D) echocardiography on the TAVI device 7 months later and she subsequently underwent surgical aortic valve replacement. Little experience of the interpretation of transoesophageal echocardiography (TEE) and the clinical course and effectiveness of treatment strategies in post-TAVI endocarditis exists. We report a case of PVE in a TAVI patient which was diagnosed with three-dimensional transoesophageal echocardiography (3DTEE). Copyright © 2016 Hellenic Cardiological Society. Published by Elsevier B.V. All rights reserved.
Prosthetic Mitral Valve Leaflet Escape
Kim, Darae; Hun, Sin Sang; Cho, In-Jeong; Shim, Chi-Young; Ha, Jong-Won; Chung, Namsik; Ju, Hyun Chul; Sohn, Jang Won
2013-01-01
Leaflet escape of prosthetic valve is rare but potentially life threatening. It is essential to make timely diagnosis in order to avoid mortality. Transesophageal echocardiography and cinefluoroscopy is usually diagnostic and the location of the missing leaflet can be identified by computed tomography (CT). Emergent surgical correction is mandatory. We report a case of fractured escape of Edward-Duromedics mitral valve 27 years after the surgery. The patient presented with symptoms of acute decompensated heart failure and cardiogenic shock. She was instantly intubated and mechanically ventilated. After prompt evaluation including transthoracic echocardiography and CT, the escape of the leaflet was confirmed. The patient underwent emergent surgery for replacement of the damaged prosthetic valves immediately. Eleven days after the surgery, the dislodged leaflet in iliac artery was removed safely and the patient recovered well. PMID:23837121
Factors influencing mortality after bioprosthetic valve replacement; a midterm outcome.
Javadzadegan, Hassan; Javadzadegan, Amir; Mehdizadeh Baghbani, Jafar
2013-01-01
Although valve repair is applied routinely nowadays, particularly for mitral regurgitation (MR) or tricuspid regurgitation (TR), valve replacement using prosthetic valves is also common especially in adults. Unfortunately the valve with ideal hemodynamic performance and long-term durability without increasing the risk of bleeding due to long-term anticoagulant therapy has not been introduced. Therefore, patients and physicians must choose either bioprosthetic or mechanical valves. Currently, there is an increasing clinical trend of using bioprosthetic valves instead of mechanical valves even in young patients apparently because of their advantages. Seventy patients undergone valvular replacement using bioprosthetic valves were evaluated by ECG and Echocardiography to assess the rhythm and ejection fracture. Mean follow-up time was 33 months (min 9, max 92). Mortality rate was 25.9% (n=18) within 8 years of follow-up. Statistical analysis showed a significant relation between atrial fibrillation rhythm and mortality (P=0.02). Morbidities occurred in 30 patients (42.8%). Significant statistical relation was found between the morbidities and age over 65 years old (P=0.005). In follow-up period, 4 cases (5.7%) underwent re-operation due to global valve dysfunction. Our study shows that using biprosthetic valve could reduce the risk of morbidity occurrence in patient who needs valve replacement. However, if medical treatments fail, patients should be referred for surgery. This would reduce the risk of mortality because of lower incident of complications such as atrial fibrillation and morbidities due to younger patients' population.
Factors Influencing Mortality after Bioprosthetic Valve Replacement; A Midterm Outcome
Javadzadegan, Hassan; Javadzadegan, Amir; Mehdizadeh Baghbani, Jafar
2013-01-01
Introduction: Although valve repair is applied routinely nowadays, particularly for mitral regurgitation (MR) or tricuspid regurgitation (TR), valve replacement using prosthetic valves is also common especially in adults. Unfortunately the valve with ideal hemodynamic performance and long-term durability without increasing the risk of bleeding due to long-term anticoagulant therapy has not been introduced. Therefore, patients and physicians must choose either bioprosthetic or mechanical valves. Currently, there is an increasing clinical trend of using bioprosthetic valves instead of mechanical valves even in young patients apparently because of their advantages. Methods: Seventy patients undergone valvular replacement using bioprosthetic valves were evaluated by ECG and Echocardiography to assess the rhythm and ejection fracture. Mean follow-up time was 33 months (min 9, max 92). Results: Mortality rate was 25.9% (n=18) within 8 years of follow-up. Statistical analysis showed a significant relation between atrial fibrillation rhythm and mortality (P=0.02). Morbidities occurred in 30 patients (42.8%). Significant statistical relation was found between the morbidities and age over 65 years old (P=0.005). In follow-up period, 4 cases (5.7%) underwent re-operation due to global valve dysfunction. Conclusion: Our study shows that using biprosthetic valve could reduce the risk of morbidity occurrence in patient who needs valve replacement. However, if medical treatments fail, patients should be referred for surgery. This would reduce the risk of mortality because of lower incident of complications such as atrial fibrillation and morbidities due to younger patients' population. PMID:24404348
Sacco, Keith A; Burton, M Caroline
2017-01-01
A 63 year old female was admitted for investigation of worsening renal insufficiency. During hospitalization she developed persistent immune thrombocytopenia refractory to supportive or immunosuppressive treatment. She was diagnosed with Mycobacterium chimaera prosthetic valve endocarditis and thrombocytopenia resolved with anti-mycobacterial therapy.
van Gorp, Maarten J; van der Graaf, Yolanda; de Mol, Bas A J M; Bakker, Chris J G; Witkamp, Theo D; Ramos, Lino M P; Mali, Willem P T M
2004-03-01
To assess the relationship between heart valve history and susceptibility artifacts at magnetic resonance (MR) imaging of the brain in patients with Björk-Shiley convexoconcave (BSCC) valves. MR images of the brain were obtained in 58 patients with prosthetic heart valves: 20 patients had BSCC valve replacements, and 38 had other types of heart valves. Two experienced neuroradiologists determined the presence or absence of susceptibility artifacts in a consensus reading. Artifacts were defined as characteristic black spots that were visible on T2*-weighted gradient-echo MR images. The statuses of the 20 explanted BSCC valves-specifically, whether they were intact or had an outlet strut fracture (OSF) or a single-leg fracture (SLF)-had been determined earlier. Number of artifacts seen at brain MR imaging was correlated with explanted valve status, and differences were analyzed with nonparametric statistical tests. Significantly more patients with BSCC valves (17 [85%] of 20 patients) than patients with other types of prosthetic valves (18 [47%] of 38 patients) had susceptibility artifacts at MR imaging (P =.005). BSCC valve OSFs were associated with a significantly higher number of artifacts than were intact BSCC valves (P =.01). No significant relationship between SLF and number of artifacts was observed. Susceptibility artifacts at brain MR imaging are not restricted to patients with BSCC valves. These artifacts can be seen on images obtained in patients with various other types of fractured and intact prosthetic heart valves. Copyright RSNA, 2004
Mechanical valve obstruction: Review of diagnostic and treatment strategies
Salamon, Jason; Munoz-Mendoza, Jerson; Liebelt, Jared J; Taub, Cynthia C
2015-01-01
Prosthetic valve obstruction (PVO) is a rare but feared complication of mechanical valve replacement. Diagnostic evaluation should focus on differentiating prosthetic valve thrombosis (PVT) from pannus formation, as their treatment options differ. History of sub-optimal anti-coagulation and post-op time course to development of PVO are useful clinical characteristics in differentiating thrombus from pannus formation. Treatment of PVT is influenced by the patient’s symptoms, valve location, degree of obstruction and thrombus size and may include thrombolysis or surgical intervention. Alternatively, pannus formation requires surgical intervention. The purpose of this article is to review the pathophysiology, epidemiology, diagnostic approach and treatment options for aortic and mitral valve PVO. PMID:26730292
Tao, Ende; Wan, Li; Wang, WenJun; Luo, YunLong; Zeng, JinFu; Wu, Xia
2017-01-01
Objective Surgery remains the primary form of treatment for infective endocarditis (IE). However, it is not clear what type of prosthetic valve provides a better prognosis. We conducted a meta-analysis to compare the prognosis of infective endocarditis treated with biological valves to cases treated with mechanical valves. Methods Pubmed, Embase and Cochrane databases were searched from January 1960 to November 2016.Randomized controlled trials, retrospective cohorts and prospective studies comparing outcomes between biological valve and mechanical valve management for infective endocarditis were analyzed. The Newcastle-Ottawa Scale(NOS) was used to evaluate the quality of the literature and extracted data, and Stata 12.0 software was used for the meta-analysis. Results A total of 11 publications were included; 10,754 cases were selected, involving 6776 cases of biological valves and 3,978 cases of mechanical valves. The all-cause mortality risk of the biological valve group was higher than that of the mechanical valve group (HR = 1.22, 95% CI 1.03 to 1.44, P = 0.023), as was early mortality (RR = 1.21, 95% CI 1.02 to 1.43, P = 0.033). The recurrence of endocarditis (HR = 1.75, 95% CI 1.26 to 2.42, P = 0.001), as well as the risk of reoperation (HR = 1.79, 95% CI 1.15 to 2.80, P = 0.010) were more likely to occur in the biological valve group. The incidence of postoperative embolism was less in the biological valve group than in the mechanical valve group, but this difference was not statistically significant (RR = 0.90, 95% CI 0.76 to 1.07, P = 0.245). For patients with prosthetic valve endocarditis (PVE), there was no significant difference in survival rates between the biological valve group and the mechanical valve group (HR = 0.91, 95% CI 0.68 to 1.21, P = 0.520). Conclusion The results of our meta-analysis suggest that mechanical valves can provide a significantly better prognosis in patients with infective endocarditis. There were significant differences in the clinical features of patients receiving a biological valve compared to patients receiving a mechanical valve. A large, multicenter retrospective study included in our meta-analysis suggested that any mortality risk of the biological valve group was significant higher than that of the mechanical valve group. However, the risk was no different after risk was adjusted. So, we thought the reason for this result may be related to the characteristics of the patient rather than valve dysfunction. It is still necessary to future randomized studies to verify this conclusion. PMID:28407024
Yamaki, F; Nakano, K; Endo, M; Hashimoto, A; Koyanagi, H
1994-02-01
Although a high incidence of strut fracture of the Björk-Shiley convexo-concave (C-C) valve prosthesis has been reported, it is still controversial whether the prosthesis functioning normally should be replaced electively. To clarify our policy for this issue, we reviewed 28 patients who had undergone mitral valve replacement with a C-C valve prosthesis, and evaluated long-term results according to STS guidelines. The incidence of valve-related complications expressed as % patient-year were; structural deterioration 0.30, nonstructural dysfunction 0.30, thromboembolism 1.20. There were no thrombosed valves, anticoagulant-related hemorrhage or prosthetic valve endocarditis. The actuarial free rate after valve replacement with the C-C at 10 years, constructed by the Kaplan-Meier method, were compared with those with St. Jude Medical (SJM) valve prosthesis. (1) Actuarial survival: 77.9 vs 87.3 (NS), (2) Reoperation-free: 91.6 vs 98.0 (p < 0.05), (3) thromboembolism-free: 83.7 vs 83.9 (NS), (4) Event-free (hospital death+reoperation+valve-related complications: 71.2 vs 77.7 (NS). The long-term results with the C-C were compatible to those with a SJM valve prosthesis. However, if a strut fracture occurs, it is very difficult to save the patient's life. The hospital mortality of re-replacement of valve prosthesis during the last 10 years, at our institute, was 2.6%, which is almost equal to the cumulative risk of strut fracture of the C-C valve after 10 years (3.0%).(ABSTRACT TRUNCATED AT 250 WORDS)
[Late outlet strut fracture of an aortic Björk-Shiley and embolization of the prosthetic disc].
Brochet, E; Bougis de Brux, M A; Assayag, P; Benacin, Y; Gamerman, G; Guerot, C; Valère, P E
1988-09-01
A new case of late fracture of an outlet strut in a convexo-concave Björk-Shiley valve is reported. The fracture occurred 6 years after aortic implantation of the valve and was responsible for aorto-iliac embolization by the prosthetic disc and death of the patient from cardiogenic shock. This not uncommon complication of the Björk-Shiley valve prosthesis is usually ascribed to the relative fragility of its outlet strut welded to the metallic ring and subjected to strong pressures. Although most cases were observed within the first two years of prosthetic valve insertion, and mainly with valves manufactured in 1981 and 1982, our case and a few others demonstrate the possibility of late rupture. Cardiologists must be aware of this possible complication, since in some favourable cases it can be diagnosed at an early stage and the patient's life can be saved by an emergency operation.
Hasler, David; Obrist, Dominik
2018-01-01
The flow field past a prosthetic aortic valve comprises many details that indicate whether the prosthesis is functioning well or not. It is, however, not yet fully understood how an optimal flow scenario would look, i.e. which subtleties of the fluid dynamics in place are essential regarding the durability and compatibility of a prosthetic valve. In this study, we measured and analyzed the 3D flow field in the vicinity of a bio-prosthetic heart valve in function of the aortic root size. The measurements were conducted within aortic root phantoms of different size, mounted in a custom-built hydraulic setup, which mimicked physiological flow conditions in the aorta. Tomographic particle image velocimetry was used to measure the 3D instantaneous velocity field at various instances. Several 3D fields (e.g. instantaneous and mean velocity, 3D shear rate) were analyzed and compared focusing on the impact of the aortic root size, but also in order to gain general insight in the 3D flow structure past the bio-prosthetic valve. We found that the diameter of the aortic jet relative to the diameter of the ascending aorta is the most important parameter in determining the characteristics of the flow. A large aortic cross-section, relative to the cross-section of the aortic jet, was associated with higher levels of turbulence intensity and higher retrograde flow in the ascending aorta.
Thrombolytic therapy for mitral valve thrombosis.
Lin, T K; Tsai, L M; Chen, J H; Yang, Y J
1997-05-01
A 44-year-old man with a St. Jude mitral valve was admitted because of progressive pulmonary edema. He was diagnosed with prosthetic heart valve thrombosis (PHVT) based on the findings of "muffled" prosthetic valve clicks. Doppler echocardiographic evidence of severe mitral stenosis and transesophageal echocardiographic evidence of limited mitral valve motility. Because the patient hesitated to undergo our recommended surgical treatment, he was immediately treated with intravenous recombinant tissue plasminogen activator (100 mg over 3 h) followed by heparinization. Two hours after the thrombolytic therapy, the prosthetic valve clicks became clearly audible and his congestive symptoms were dramatically improved. Follow-up echocardiography no longer-showed significant mitral valve obstruction. A transient cerebral ischemic attack occurred at the end of thrombolytic therapy but there were no neurologic sequalae. The patient, on warfarin therapy, was well at follow-up 8 months after discharge. Surgical intervention has long been the standard therapy for patients with PHVT. Our case experience suggests that thrombolytic therapy may be considered as an effective alternative to surgical intervention for selected patients with PHVT. In this report, we also review the current literature regarding the indications, effectiveness and safety of thrombolytic therapy in PHVT.
Risks and Challenges of Surgery for Aortic Prosthetic Valve Endocarditis.
Grubitzsch, Herko; Tarar, Waharat; Claus, Benjamin; Gabbieri, Davide; Falk, Volkmar; Christ, Torsten
2018-03-01
Prosthetic valve endocarditis is the most severe form of infective endocarditis. This study assessed the risks and challenges of surgery for aortic prosthetic valve endocarditis. In total, 116 consecutive patients (98 males, age 65.2±12.7years), who underwent redo-surgery for active aortic prosthetic valve endocarditis between 2000 and 2014, were reviewed. Cox regression analysis was used to identify factors for aortic root destructions as well as for morbidity and mortality. Median follow-up was 3.8 years (0-13.9 years). Aortic root destructions (42 limited and 29 multiple lesions) were associated with early prosthetic valve endocarditis and delayed diagnosis (≥14 d), but not with mortality. There were 16 (13.8%) early (≤30 d) and 32 (27.6%) late (>30 days) deaths. Survival at 1, 5, and 10 years was 72±4.3%, 56±5.4%, and 46±6.4%, respectively. The cumulative incidence of death, reinfection, and reoperation was 19.0% at 30days and 36.2% at 1year. Delayed diagnosis, concomitant procedures, and EuroSCORE II >20% were predictors for early mortality and need for mechanical circulatory support, age >70years, and critical preoperative state were predictors for late mortality. In their absence, survival at 10 years was 70±8.4%. Reinfections and reoperations occurred more frequently if ≥1 risk factor for endocarditis and aortic root destructions were present. At 10 years, freedom from reinfection and reoperation was 89±4.2% and 91±4.0%. The risks of death, reinfection, and reoperation are significant within the first year after surgery for aortic prosthetic valve endocarditis. Early diagnosis and aortic root destructions are the most important challenges, but advanced age, critical preoperative state, and the need for mechanical circulatory support determine long-term survival. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Polymeric trileaflet prosthetic heart valves: evolution and path to clinical reality
Claiborne, Thomas E; Slepian, Marvin J; Hossainy, Syed; Bluestein, Danny
2013-01-01
Present prosthetic heart valves, while hemodynamically effective, remain limited by progressive structural deterioration of tissue valves or the burden of chronic anticoagulation for mechanical valves. An idealized valve prosthesis would eliminate these limitations. Polymeric heart valves (PHVs), fabricated from advanced polymeric materials, offer the potential of durability and hemocompatibility. Unfortunately, the clinical realization of PHVs to date has been hampered by findings of in vivo calcification, degradation and thrombosis. Here, the authors review the evolution of PHVs, evaluate the state of the art of this technology and propose a pathway towards clinical reality. In particular, the authors discuss the development of a novel aortic PHV that may be deployed via transcatheter implantation, as well as its optimization via device thrombogenicity emulation. PMID:23249154
Lee, Candice Y; Wong, Joshua K; Ross, Ronald E; Liu, David C; Khabbaz, Kamal R; Martellaro, Angelo J; Gorea, Heather R; Sauer, Jude S; Knight, Peter A
Prostheses attachment is critical in aortic valve replacement surgery, yet reliable prosthetic security remains a challenge. Accurate techniques to analyze prosthetic fixation pressures may enable the use of fewer sutures while reducing the risk of paravalvular leaks (PVL). Customized digital thin film pressure transducers were sutured between aortic annulus models and 21-mm bioprosthetic valves with 15 × 4-mm, 12 × 4-mm, or 9 × 6-mm-wide pledgeted mattress sutures. Simulating open and minimally invasive access, 4 surgeons, blinded to data acquisition, each secured 12 valves using manual knot-tying (hand-tied [HT] or knot-pusher [KP]) or automated titanium fasteners (TFs). Real-time pressure measurements and times were recorded. Two-dimensional (2D) and 3D pressure maps were generated for all valves. Pressures less than 80 mm Hg were considered at risk for PVL. Pressures under each knot (intrasuture) fell less than 80 mm Hg for 12 of 144 manual knots (5/144 HT, 7/144 KP) versus 0 of 288 TF (P < 0.001). Pressures outside adjacent sutures (extrasuture) were less than 80 mm Hg in 10 of 60 HT, zero of 60 KP, and zero of 120 TF sites for 15 × 4-mm valves; 17 of 48 HT, 25 of 48 KP, and 12 of 96 TF for 12 × 4-mm valves; and 15 of 36 HT, 17 of 36 KP, and 9 and 72 TF for 9 × 6-mm valves; P < 0.001 all manual versus TF. Annular areas with pressures less than 80 mm Hg ranged from 0% of the sewing-ring area (all open TF) to 31% (12 × 4 mm, KP). The average time per manual knot, 46 seconds (HT, 31 seconds; KP, 61 seconds), was greater than TF, 14 seconds (P < 0.005). Reduced operative times and PVL risk would fortify the advantages of surgical aortic valve replacement. This research encourages continued exploration of technical factors in optimizing prosthetic valve security.
Mamdani, Natasha; Shah, Jatan; Simms, Michael
2017-02-01
Cardiobacterium hominis is an uncommon cause of prosthetic valve endocarditis (PVE) and often presents insidiously. In comparison, prosthetic valve thrombosis (PVT) is a rare, but life-threatening condition that commonly occurs due to inadequate anticoagulation. Anticoagulation is relatively contraindicated in patients with endocarditis as it may prove to be lethal due to increased risk of cerebral hemorrhage. However, anticoagulation is required in patients with PVT, or for its prevention. We present a case of a 35-year-old male with a history of hypercoagulability and St. Jude's aortic valve on warfarin, who presented with chest pain andwas found to have a mass on the aorticvalve, with blood cultures revealing C. hominis.The patient was treated with appropriate antibiotics and anticoagulation was continued. No neurological complications were noted during the treatment period. This case demonstrates that carefully weighing the risks and benefits of continuing anticoagulation is essential in preventing poor outcomes.
Are prosthetic heart valve fibrin strands negligible? The associations and significance.
Kiavar, Majid; Sadeghpour, Anita; Bakhshandeh, Hooman; Tayyebi, Parisa; Bassiri, Hossein Ali; Esmaeilzadeh, Maryam; Maleki, Majid; Noohi, Feridoun
2009-08-01
Filamentous fibrin strands (FSs) attached to valve prostheses have been well described in patients undergoing transesophageal echocardiography, but the frequency and clinical significance of these strands remain poorly defined. The aims of this study were to determine the frequency of prosthetic valve strands and to assess their significance in relation to clinical cerebral ischemic events (CIEs) and anticoagulant status. Three hundred consecutive patients with 421 prosthetic heart valves were evaluated for the presence of FSs (highly mobile, filamentous masses<1 mm thick). FSs were found in 139 patients (49%) and 147 prostheses (38%) in patients with left-sided prostheses, with a significant association between FSs, CIEs, and anticoagulant status (P<.001). A lower international normalized ratio (<2.5) had a positive association with the occurrence of CIEs. There is a significant association between FSs, CIEs, and patient's anticoagulant status; therefore, aggressive anticoagulation and close follow-up are recommended for these patients.
Belov, Iu V; Stepanenko, A B; Gens, A P; Charchian, E R; Savichev, D D
2007-01-01
Simultaneous surgical interventions on the aorta and valvular system of the heart were performed in four patients presenting with aortic dissections and aneurysms conditioned by Marfan's syndrome. The following reconstructive operations were carried out: 1) prosthetic repair of the aortic valve and the ascending portion of the aorta by means of a valve-containing conduit with replantation of the openings of the coronary arteries into the side of the prosthesis according to the Benthall - De Bono technique, annuloplasty of the tricuspid valve according to the De Vega technique, valvuloplasty of the mitral valve by the Alferi technique; 2) grafting of the aortic valve and the ascending portion of the aorta by means of a valve-containing conduit with replantation of the openings of the coronary arteries according to the Kabrol's technique, plasty of the tricuspid valve by the De Vega technique; 3) prosthetic repair of the aortic arch with distal wedge-like excision of the membrane of the dissection and directing the blood flow along the both channels, plasty of the mitral valve, plasty of the aortic valve and the ascending portion of the aorta with a valve-containing conduit, accompanied by replantation of the openings of the coronary arteries into the side of the graft according to the Benthall - De Bono technique; (4) plasty of the mitral valve with a disk graft through the fibrous ring of the aortic valve, prosthetic repair of the aortic valve and the ascending portion of the aorta with a valve-containing conduit, accompanied by replantation of the openings of the coronary arteries into the side according to the Benthall-De Bono technique.
Surgical treatment of Behçet's disease involving aortic regurgitation.
Ando, M; Kosakai, Y; Okita, Y; Nakano, K; Kitamura, S
1999-12-01
Behçet's disease involving aortic regurgitation is rare, and prosthetic valve detachment after aortic valve replacement is one of the most serious complications reported. We investigated the surgical results in 10 patients with aortic regurgitation caused by Behçet's disease. Between 1981 and 1997, 10 patients with aortic regurgitation secondary to Behçet's disease had surgery. There were 8 men and 2 women, and their ages ranged from 33 to 60 years (mean, 46+/-8 years). The surgical procedures for aortic regurgitation were aortic valve replacement in 6 patients and Bentall type operation in 4. No patient died during the hospital stay. The follow-up periods ranged from 11 to 185 months (mean, 87 months). Two patients died during the follow-up period. The acturial survival rate was 89% at 5 years and 67% at 10 years. Prosthetic valve detachment or suture detachment requiring redo operation occurred in 4 patients, 3 of whom had redo operations twice. Four patients had a composite graft replacement, and 1 patient died after the operation. No prosthetic valve detachment was noted in 64% of the patients at 5 years and in 43% at 10 years. The rate of prosthetic valve detachment was 40% (4 of 10 patients), with a higher incidence in patients with Behçet's disease than in those treated during the same period at the same hospital for aortitis caused by other diseases. Surgical techniques for treatment of this condition should be modified to improve the surgical outcome in these patients.
Fatal association of mechanical valve thrombosis with dabigatran: a report of two cases.
Atar, Shaul; Wishniak, Alice; Shturman, Alexander; Shtiwi, Sewaed; Brezins, Marc
2013-07-01
Several new oral anticoagulants have been approved for thromboembolism prevention in patients with nonvalvular atrial fibrillation. However, they are not yet approved for anticoagulation use in patients with prosthetic mechanical valves, and no randomized data have been published so far on their safety of use in these patients. We present two cases of patients with prosthetic mechanical mitral valves who were switched from warfarin and acenocoumarol to dabigatran and within 1 month experienced severe valve complications resulting in death. One patient experienced stroke and later cardiogenic shock and death, and the other experienced pulmonary edema, cardiogenic shock, and subsequent death.
Nuclear Medicine in Diagnosis of Prosthetic Valve Endocarditis: An Update
Musso, Maria; Petrosillo, Nicola
2015-01-01
Over the past decades cardiovascular disease management has been substantially improved by the increasing introduction of medical devices as prosthetic valves. The yearly rate of infective endocarditis (IE) in patient with a prosthetic valve is approximately 3 cases per 1,000 patients. The fatality rate of prosthetic valve endocarditis (PVE) remains stable over the years, in part due to the aging of the population. The diagnostic value of echocardiography in diagnosis is operator-dependent and its sensitivity can decrease in presence of intracardiac devices and valvular prosthesis. The modified Duke criteria are considered the gold standard for diagnosing IE; their sensibility is 80%, but in clinical practice their diagnostic accuracy in PVE is lower, resulting inconclusively in nearly 30% of cases. In the last years, these new imaging modalities have gained an increasing attention because they make it possible to diagnose an IE earlier than the structural alterations occurring. Several studies have been conducted in order to assess the diagnostic accuracy of various nuclear medicine techniques in diagnosis of PVE. We performed a review of the literature to assess the available evidence on the role of nuclear medicine techniques in the diagnosis of PVE. PMID:25695043
Identification of critical zones in the flow through prosthetic heart valves
NASA Astrophysics Data System (ADS)
Lopez, A.; Ledesma, R.; Zenit, R.; Pulos, G.
2008-11-01
The hemodynamic properties of prosthetic heart valves can cause blood damage and platelet activation due to the non- physiological flow patterns. Blood recirculation and elevated shear stresses are believed to be responsible for these complications. The objective of this study is to identify and quantify the conditions for which recirculation and high stress zones appear. We have performed a comparative study between a mechanical monoleaflet and biological valve. In order to generate the flow conditions to test the prosthesis, we have built a hydraulic circuit which reproduces the human systemic circulation, on the basis of the Windkessel model. This model is based on an electrical analogy which consists of an arterial resistance and compliance. Using PIV 3D- Stereo measurements, taken downstream from the prosthetic heart valves, we have reconstructed the full phase-averaged tridimensional velocity field. Preliminary results show that critical zones are more prominent in mechanical prosthesis, indicating that valves made with bio-materials are less likely to produce blood trauma. This is in accordance with what is generally found in the literature.
Development of reversible vas deferens occlusive device: IV. Rigid prosthetic devices.
Drueschke, E E; Zaneveld, L J; Burns, M; Rodzen, R; Wingfield, J R; Maness, J H
1975-01-01
Different types of rigid, reversible, vas deferens occlusive devices were developed and evaluated in 14 unilaterally vasectomized dogs. All prosthetic devices had molded silicone rubber bodies, and rigid inflow and outflow tubes. Various techniques for the removal of the vas luminal epithelium, and for the preparation of porous ceramic and etched stainless steel surfaces to encourage tissue ingrowth into the prosthetic device end tubues were attempted. The devices differed in their methods of achieving occlusion. One device used a "rotary stem valve" which had a C-section rotating mechanism; the others used the "shuttle stem valve" which possessed an occlusive element that moved transverse to the axis of flow in the device, thus occluding the device when the stem was depressed. The rotarystem valve was implanted by means of a longitudinal incision. The remaining 13 shuttle stem devices were placed in the vas using either a longitudinal or a transverse implantation. Inno case was sperm transport through the prosthetic devices obtained for more than a few ejaculations.
Flow in prosthetic heart valves: state-of-the-art and future directions.
Yoganathan, Ajit P; Chandran, K B; Sotiropoulos, Fotis
2005-12-01
Since the first successful implantation of a prosthetic heart valve four decades ago, over 50 different designs have been developed including both mechanical and bioprosthetic valves. Today, the most widely implanted design is the mechanical bileaflet, with over 170,000 implants worldwide each year. Several different mechanical valves are currently available and many of them have good bulk forward flow hemodynamics, with lower transvalvular pressure drops, larger effective orifice areas, and fewer regions of forward flow stasis than their earlier-generation counterparts such as the ball-and-cage and tilting-disc valves. However, mechanical valve implants suffer from complications resulting from thrombus deposition and patients implanted with these valves need to be under long-term anti-coagulant therapy. In general, blood thinners are not needed with bioprosthetic implants, but tissue valves suffer from structural failure with, an average life-time of 10-12 years, before replacement is needed. Flow-induced stresses on the formed elements in blood have been implicated in thrombus initiation within the mechanical valve prostheses. Regions of stress concentration on the leaflets during the complex motion of the leaflets have been implicated with structural failure of the leaflets with bioprosthetic valves. In vivo and in vitro experimental studies have yielded valuable information on the relationship between hemodynamic stresses and the problems associated with the implants. More recently, Computational Fluid Dynamics (CFD) has emerged as a promising tool, which, alongside experimentation, can yield insights of unprecedented detail into the hemodynamics of prosthetic heart valves. For CFD to realize its full potential, however, it must rely on numerical techniques that can handle the enormous geometrical complexities of prosthetic devices with spatial and temporal resolution sufficiently high to accurately capture all hemodynamically relevant scales of motion. Such algorithms do not exist today and their development should be a major research priority. For CFD to further gain the confidence of valve designers and medical practitioners it must also undergo comprehensive validation with experimental data. Such validation requires the use of high-resolution flow measuring tools and techniques and the integration of experimental studies with CFD modeling.
Xu, Tong-yi; Zhang, Zhi-gang; Li, Xin; Han, Lin; Xu, Zhi-yun
2014-01-01
Background Since 2000, transcatheter pulmonary valve replacement has steadily advanced. However, the available prosthetic valves are restricted to bioprosthesis which have defects like poor durability. Polymeric heart valve is thought as a promising alternative to bioprosthesis. In this study, we introduced a novel polymeric transcatheter pulmonary valve and evaluated its feasibility and safety in sheep by a hybrid approach. Methods We designed a novel polymeric trileaflet transcatheter pulmonary valve with a balloon-expandable stent, and the valve leaflets were made of 0.1-mm expanded polytetrafluoroethylene (ePTFE) coated with phosphorylcholine. We chose glutaraldehyde-treated bovine pericardium valves as control. Pulmonary valve stents were implanted in situ by a hybrid transapical approach in 10 healthy sheep (8 for polymeric valve and 2 for bovine pericardium valve), weighing an average of 22.5±2.0 kg. Angiography and cardiac catheter examination were performed after implantation to assess immediate valvular functionality. After 4-week follow-up, angiography, echocardiography, computed tomography, and cardiac catheter examination were used to assess early valvular function. One randomly selected sheep with polymeric valve was euthanized and the explanted valved stent was analyzed macroscopically and microscopically. Findings Implantation was successful in 9 sheep. Angiography at implantation showed all 9 prosthetic valves demonstrated orthotopic position and normal functionality. All 9 sheep survived at 4-week follow-up. Four-week follow-up revealed no evidence of valve stent dislocation or deformation and normal valvular and cardiac functionality. The cardiac catheter examination showed the peak-peak transvalvular pressure gradient of the polymeric valves was 11.9±5.0 mmHg, while that of two bovine pericardium valves were 11 and 17 mmHg. Gross morphology demonstrated good opening and closure characteristics. No thrombus or calcification was seen macroscopically. Conclusions This design of the novel ePTFE transcatheter pulmonary valve is safe and effective to deploy in sheep by hybrid approach, and the early valvular functionality is good. PMID:24926892
Late leaflet fracture and embolization of a Duromedics mitral prosthesis.
Sudo, K; Sasagawa, N; Ide, H; Nunokawa, M; Fujiki, T; Tonari, K
2000-08-01
A case of leaflet fracture and embolization of a mitral prosthetic valve is described. A 54-year-old man had received mitral valve replacement with an Edwards-Duromedics 29M prosthetic valve, at 10 years ago. Emergency mitral valve replacement was performed because the patient had severe congestive left heart failure with severe acute mitral regurgitation caused by a fracture in one of the mitral valve leaflets. The leaflet, which was fractured into 2 pieces, was removed from the right common iliac artery at 3 months after valve replacement. Visual inspection revealed that the leaflet contained a midline fracture. The fracture originated within a cavitary erosion pit near the major radius of the leaflet. The patient recovered from acute renal failure, requiring hemodialysis for 80 days, and is currently without complaints. We have used a Duromedics mitral valve in 11 patients, from April 1987 to April 1988. No subsequent valve failure has occurred. The diagnosis, treatment and cause of a mechanical valve fracture are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scott, D.D.; Jones, H.E.
1994-05-06
Prosthetic heart valves have increased the life span of many patients with life threatening heart conditions. These valves have proven extremely reliable adding years to what would have been weeks to a patient`s life. Prosthetic valves, like the heart however, can suffer from this constant work load. A small number of valves have experienced structural fractures of the outlet strut due to fatigue. To study this problem a non-intrusive method to classify valves has been developed. By extracting from an acoustic signal the opening sounds which directly contain information from the outlet strut and then developing features which are suppliedmore » to an adaptive classification scheme (neural network) the condition of the valve can be determined. The opening sound extraction process has proved to be a classification problem itself. Due to the uniqueness of each heart and the occasional irregularity of the acoustic pattern it is often questionable as to the integrity of a given signal (beat), especially one occurring during an irregular beat pattern. A common cause of these irregular patterns is a condition known as atrial fibrillation, a prevalent arrhythmia among patients with prosthetic hear valves. Atrial fibrillation is suspected when the ECG shows no obvious P-waves. The atria do not contract and relax correctly to help contribute to ventricular filling during a normal cardiac cycle. Sometimes this leads to irregular patterns in the acoustic data. This study compares normal beat patterns to irregular patterns of the same heart. By analyzing the spectral content of the beats it can be determined whether or not these irregular patterns can contribute to the classification of a heart valve or if they should be avoided. The results have shown that the opening sounds which occur during irregular beat patterns contain the same spectral information as the opening which occur during a normal beat pattern of the same heart and these beats can be used for classification.« less
Twenty-Year Experience in the Diagnosis and Treatment of Infective Endocarditis.
Abramczuk, Elżbieta; Stępińska, Janina; Hryniewiecki, Tomasz
2015-01-01
The aim of this study was to compare the etiology, clinical course, selected diagnostic methods and efficacy of the treatment used in patients with infective endocarditis (IE) in the nineteen eighties and nineties. The study group comprised 300 patients with infective endocarditis hospitalized in the Institute of Cardiology in Warsaw in the following years: from 1982 to 1987 (150 patients: 75 successive patients with IE on the prosthetic valve and 75 successive patients with IE on the native valve), as well as from 1990 to 2003 (150 patients: 75 successive patients with IE on the prosthetic valve and 75 successive patients with IE on the native valve). In the nineties, immunological symptoms, embolism formation and progressive heart failure were diagnosed decidedly more frequently. Early prosthetic valve endocarditis (PVE) (up to 60 days after operation) occurred significantly more frequently in the eighties. The quantity of negative blood cultures in PVE has not decreased, it is still observed in over 20% of cases. For 20 years the etiology of PVE has remained the same, the dominant pathogen remains Staphylococcus. The frequency of PVE caused by Streptococci has markedly reduced. In both the decades analyzed the etiology of native valve endocarditis (NVE) was similar. In the eighties Streptococcus was predominant. In successive years the number of infections caused by Staphylococci was the same as that caused by Streptococci. The incidence of early PVE decreased in the nineties. More patients were treated surgically with lesser peri-operative mortality. A lower incidence of infective endocarditis on prosthetic valves caused by streptococci may signify better prophylaxis against infective endocarditis. Infective endocarditis with sterile blood cultures continues to occur frequently.
Twenty-Year Experience in the Diagnosis and Treatment of Infective Endocarditis
2015-01-01
Aims The aim of this study was to compare the etiology, clinical course, selected diagnostic methods and efficacy of the treatment used in patients with infective endocarditis (IE) in the nineteen eighties and nineties. Material and Methods The study group comprised 300 patients with infective endocarditis hospitalized in the Institute of Cardiology in Warsaw in the following years: from 1982 to 1987 (150 patients: 75 successive patients with IE on the prosthetic valve and 75 successive patients with IE on the native valve), as well as from 1990 to 2003 (150 patients: 75 successive patients with IE on the prosthetic valve and 75 successive patients with IE on the native valve). Results In the nineties, immunological symptoms, embolism formation and progressive heart failure were diagnosed decidedly more frequently. Early prosthetic valve endocarditis (PVE) (up to 60 days after operation) occurred significantly more frequently in the eighties. The quantity of negative blood cultures in PVE has not decreased, it is still observed in over 20% of cases. For 20 years the etiology of PVE has remained the same, the dominant pathogen remains Staphylococcus. The frequency of PVE caused by Streptococci has markedly reduced. In both the decades analyzed the etiology of native valve endocarditis (NVE) was similar. In the eighties Streptococcus was predominant. In successive years the number of infections caused by Staphylococci was the same as that caused by Streptococci. Conclusions The incidence of early PVE decreased in the nineties. More patients were treated surgically with lesser peri-operative mortality. A lower incidence of infective endocarditis on prosthetic valves caused by streptococci may signify better prophylaxis against infective endocarditis. Infective endocarditis with sterile blood cultures continues to occur frequently. PMID:26230402
Effect of the sinus of valsalva on the closing motion of bileaflet prosthetic heart valves.
Ohta, Y; Kikuta, Y; Shimooka, T; Mitamura, Y; Yuhta, T; Dohi, T
2000-04-01
Conventional bileaflet prosthetic mechanical heart valves close passively with backflow. Naturally, the valve has problems associated with closure, such as backflow, water hammer effect, and fracture of the leaflet. On the other hand, in the case of the natural aortic valve, the vortex flow in the sinus of Valsalva pushes the leaflet to close, and the valve starts the closing motion earlier than the prosthetic valve as the forward flow decelerates. This closing mechanism is thought to decrease backflow at valve closure. In this study, we propose a new bileaflet mechanical valve resembling a drawbridge in shape, and the prototype valve was designed so that the leaflet closes with the help of the vortex flow in the sinus. The test valve was made of aluminum alloy, and its closing motion was compared to that of the CarboMedics (CM) valve. Both valves were driven by a computer controlled hydraulic mock circulator and were photographed at 648 frames/s by a high speed charge-coupled device (CCD) camera. Each frame of the valve motion image was analyzed with a personal computer, and the opening angles were measured. The flow rate was set as 5.0 L/min. The system was pulsed with 70 bpm, and the systolic/diastolic ratio was 0.3. Glycerin water was used as the circulation fluid at room temperature, and polystyrene particles were used to visualize the streamline. The model of the sinus of Valsalva was made of transparent silicone rubber. As a result, high speed video analysis showed that the test valve started the closing motion 41 ms earlier than the CM valve, and streamline analysis showed that the test valve had a closing mechanism similar to the natural one with the effect of vortex flow. The structure of the test valve was thought to be effective for soft closure and could solve problems associated with closure.
Chang, Suyon; Suh, Young Joo; Han, Kyunghwa; Kim, Jin Young; Kim, Young Jin; Chang, Byung-Chul; Choi, Byoung Wook
2017-12-15
The clinical significance of pannus in the prosthetic mitral valve (MV) is not well documented. To investigate the clinical significance of pannus on cardiac computed tomography (CT) in patients with a prosthetic MV. A total of 130 patients with previous MV replacement who underwent cardiac CT were retrospectively included in this study. The presence of pannus, paravalvular leak (PVL) around the prosthetic MV and limitation of motion (LOM) of the MV were analyzed using CT. Between patients with MV pannus and those without pannus, CT, echocardiographic, and redo-surgery findings were compared. The diagnostic performance of CT and transesophageal echocardiography (TEE) for the detection of MV pannus was also compared, using surgical findings as a standard reference. MV pannus was observed on cardiac CT in 32.3% of the study population. Patients with MV pannus detected on CT more commonly had LOM (28.2% vs. 15.2%) and less frequently had PVL of the prosthetic MV (16.7% vs. 25%) than patients without MV pannus (P>0.05). Prosthetic valve obstruction (PVO) due prosthetic MV pannus requiring redo-surgery was present in only five patients (11.9%). Cardiac CT detected MV pannus with sensitivity of 65.2% and specificity of 80.9% and showed better diagnostic performance than TEE (P<0.05). Prosthetic MV pannus can frequently be seen on cardiac CT. However, its clinical significance should be assessed with careful consideration, because PVO due to MV pannus is relatively uncommon, and pannus can be seen in patients without any clinical problems. Copyright © 2017 Elsevier B.V. All rights reserved.
Reynolds Shear Stress for Textile Prosthetic Heart Valves in Relation to Fabric Design
Bark, David L.; Koupei, Atieh Yousefi; Forleo, Marcio; Vaesken, Antoine; Heim, Frederic; Dasi, Lakshmi P.
2016-01-01
The most widely implanted prosthetic heart valves are either mechanical or bioprosthetic. While the former suffers from thrombotic risks, the latter suffers from a lack of durability. Textile valves, alternatively, can be designed with durability and to exhibit hemodynamics similar to the native valve, lowering the risk for thrombosis. Deviations from native valve hemodynamics can result in an increased Reynolds Shear Stress (RSS), which has the potential to instigate hemolysis or shear-induced thrombosis. This study is aimed at characterizing flow in multiple textile valve designs with an aim of developing a low profile valve. Valves were created using a shaping process based on heating a textile membrane and placed within a left heart simulator. Turbulence and bulk hemodynamics were assessed through particle imaging velocimetry (PIV), along with flow and pressure measurements. Overall, RSS was reduced for low profile valves relative to high profile valves, but was otherwise similar among low profile valves. However, leakage was found in 3 of the 4 low profile valve designs driving the fabric design for low profile valves. Through textile design, low profile valves can be created with favorable hemodynamics. PMID:26919564
Eitz, Thomas; Schenk, Soren; Fritzsche, Dirk; Bairaktaris, Andreas; Wagner, Otto; Koertke, Heinrich; Koerfer, Reiner
2008-03-01
Although prosthetic valves are durable and easy to implant, the need for lifetime warfarin-based anticoagulation restricts their exclusive usage. We investigated if anticoagulation self-management improves outcome in a single-center series. Between 1994 and 1998, 765 patients with prosthetic valve replacements were prospectively enrolled and randomized to receive conventional anticoagulation management by their primary physician (group 1, n = 295) or to pursue anticoagulation self-management (group 2, n = 470). A study head office was implemented to coordinate and monitor anticoagulation protocols, international normalized ratios (INR), and adverse events. Patients were instructed on how to obtain and test their own blood samples and to adjust warfarin dosages according to the measured INR (target range, 2.5 to 4). Mean INR values were slightly yet significantly smaller in group 1 than in group 2 (2.8 +/- 0.7 vs 3.0 +/- .6, p < 0.001). Moreover, INR values of patients with conventional INR management were frequently measured outside the INR target range, whereas those with anticoagulation self-management mostly remained within the range (35% vs 21%, p < 0.001). In addition, the scatter of INR values was smaller if self-managed. Freedom from thromboembolism at 3, 12, and 24 months, respectively, was 99%, 95%, and 91% in group 1 compared with 99%, 98%, and 96% in group 2 (p = 0.008). Bleeding events were similar in both groups. Time-related multivariate analysis identified INR self-management and higher INR as independent predictors for better outcome. Anticoagulation self-management can improve INR profiles up to 2 years after prosthetic valve replacement and reduce adverse events. Current indications of prosthetic rather than biologic valve implantations may be extended if the benefit of INR self-management is shown by future studies with longer follow-up.
Prosthetic valve endocarditis: early and late outcome following medical or surgical treatment
Akowuah, E F; Davies, W; Oliver, S; Stephens, J; Riaz, I; Zadik, P; Cooper, G
2003-01-01
Objective: To compare the early and late outcome of medical and surgical treatment in patients with prosthetic valve endocarditis within a single unit. Design: All patients with proven prosthetic valve endocarditis treated in one institution between 1989 and 1999 were studied. Results: There were 66 patients (24 female, 42 male), mean (SD) age 57 (14) years. Of these, 28 were treated with antibiotics alone and 38 with a combination of antibiotics and surgery. The in-hospital mortality for the antibiotic group was 46% and for the surgical group, 24%. However, seven patients in the antibiotic group were considered too sick for curative treatment. The mortality in the remaining 21 medically treated patients (6/21; 29%) was not significantly different from that in the surgically treated patients (p = 0.15). Six patients in the medically treated group and one in the surgically treated group required late reoperation. Endocarditis recurred in three patients in the medically treated group, two of whom were treated surgically, and in one patient in the surgically treated group. Kaplan–Meier survival at 10 years was 28% in the medically treated group v 58% in the surgically treated group (p = 0.04). Freedom from endocarditis at five years was 60% in the surgically treated group and 65% in the medically treated group. Conclusions: Prosthetic valve endocarditis is a serious condition with high early and late mortality, irrespective of the treatment employed. These data show that selected patients with prosthetic valve endocarditis can be successfully treated with antibiotics alone. If required, surgery in this difficult group of patients can provide satisfactory freedom from recurrent infection. PMID:12591827
A 3D velocimetry study of the flow through prosthetic heart valves
NASA Astrophysics Data System (ADS)
Ledesma, R.; Zenit, R.; Pulos, G.; Sanchez, E.; Juarez, A.
2006-11-01
Blood damage commonly appears in medical valve prothesis. It is a mayor concern for the designers and surgeons. It is well known that this damage and other complications result from the modified fluid dynamics through the replacement valve. To evaluate the performance of prosthetic heart valves, it is necessary to study the flow through them. To conduct this study , we have built a flow channel that emulates cardiac conditions and allows optical access such that a 3D-PIV velocimetry system could be used. The experiments are aimed to reconstruct the downstream structure of the flow through a mechanical and a bio-material tricuspid heart valve prothesis. Preliminary results show that the observed coherent structures can be related with haemolysis and trombosis, illnesses commonly found in valve prothesis recipients. The mean flow, the levels of strain rate and the turbulence intensity generated by the valves can also be directly related to blood damage. In general, bio-material made valves tend to reduce these complications.
Evaluation of prosthetic valve thrombosis by 64-row multi-detector computed tomography. .
Tarzia, Vincenzo; Bortolussi, Giacomo; Rubino, Maurizio; Gallo, Michele; Bottio, Tomaso; Gerosa, Gino
2015-03-01
Multi-detector computed tomography (MDCT), combined with retrospective electrocardiographic gating, permits cardiac imaging with high accuracy. Recent advances in MDCT have seemed to respond adequately to the need for a non-invasive and reliable assessment of the coronary artery lumen. Two patients with prosthetic aortic valves (one bioprosthetic, one mechanical) presented at the authors' institution with dyspnea and syncopal episodes. MDCT was performed to evaluate thrombus characteristics and exclude coronary artery disease (CAD). Based on the MDCT coronary artery assessment, neither patient underwent preoperative invasive coronary angiography, abolishing the risk of any iatrogenic thrombus fragmentation and subsequent embolization. One patient underwent surgical treatment without complications, while medical therapy was successful in the other case. MDCT can be used for the accurate imaging of thrombi on prosthetic aortic valves, and to correctly assess possible CAD.
NASA Astrophysics Data System (ADS)
Hatt, Charles R.; Wagner, Martin; Raval, Amish N.; Speidel, Michael A.
2016-03-01
Transcatheter aortic valve replacement (TAVR) requires navigation and deployment of a prosthetic valve within the aortic annulus under fluoroscopic guidance. To support improved device visualization in this procedure, this study investigates the feasibility of frame-by-frame 3D reconstruction of a moving and expanding prosthetic valve structure from simultaneous bi-plane x-ray views. In the proposed method, a dynamic 3D model of the valve is used in a 2D/3D registration framework to obtain a reconstruction of the valve. For each frame, valve model parameters describing position, orientation, expansion state, and deformation are iteratively adjusted until forward projections of the model match both bi-plane views. Simulated bi-plane imaging of a valve at different signal-difference-to-noise ratio (SDNR) levels was performed to test the approach. 20 image sequences with 50 frames of valve deployment were simulated at each SDNR. The simulation achieved a target registration error (TRE) of the estimated valve model of 0.93 +/- 2.6 mm (mean +/- S.D.) for the lowest SDNR of 2. For higher SDNRs (5 to 50) a TRE of 0.04 mm +/- 0.23 mm was achieved. A tabletop phantom study was then conducted using a TAVR valve. The dynamic 3D model was constructed from high resolution CT scans and a simple expansion model. TRE was 1.22 +/- 0.35 mm for expansion states varying from undeployed to fully deployed, and for moderate amounts of inter-frame motion. Results indicate that it is feasible to use bi-plane imaging to recover the 3D structure of deformable catheter devices.
Hatt, Charles R; Wagner, Martin; Raval, Amish N; Speidel, Michael A
2016-01-01
Transcatheter aortic valve replacement (TAVR) requires navigation and deployment of a prosthetic valve within the aortic annulus under fluoroscopic guidance. To support improved device visualization in this procedure, this study investigates the feasibility of frame-by-frame 3D reconstruction of a moving and expanding prosthetic valve structure from simultaneous bi-plane x-ray views. In the proposed method, a dynamic 3D model of the valve is used in a 2D/3D registration framework to obtain a reconstruction of the valve. For each frame, valve model parameters describing position, orientation, expansion state, and deformation are iteratively adjusted until forward projections of the model match both bi-plane views. Simulated bi-plane imaging of a valve at different signal-difference-to-noise ratio (SDNR) levels was performed to test the approach. 20 image sequences with 50 frames of valve deployment were simulated at each SDNR. The simulation achieved a target registration error (TRE) of the estimated valve model of 0.93 ± 2.6 mm (mean ± S.D.) for the lowest SDNR of 2. For higher SDNRs (5 to 50) a TRE of 0.04 mm ± 0.23 mm was achieved. A tabletop phantom study was then conducted using a TAVR valve. The dynamic 3D model was constructed from high resolution CT scans and a simple expansion model. TRE was 1.22 ± 0.35 mm for expansion states varying from undeployed to fully deployed, and for moderate amounts of inter-frame motion. Results indicate that it is feasible to use bi-plane imaging to recover the 3D structure of deformable catheter devices.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fetterly, K; Mathew, V
Purpose: Transcatheter aortic valve replacement (TAVR) procedures provide a method to implant a prosthetic aortic valve via a minimallyinvasive, catheter-based procedure. TAVR procedures require use of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane to minimize prosthetic valve positioning error due to x-ray imaging parallax. The purpose of this work is to calculate the continuous range of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane from a single planar image of a valvuloplasty balloon inflated across the aortic valve. Methods: Computational methods to measure the 3D angular orientation of themore » aortic valve were developed. Required inputs include a planar x-ray image of a known valvuloplasty balloon inflated across the aortic valve and specifications of x-ray imaging geometry from the DICOM header of the image. A-priori knowledge of the species-specific typical range of aortic orientation is required to specify the sign of the angle of the long axis of the balloon with respect to the x-ray beam. The methods were validated ex-vivo and in a live pig. Results: Ex-vivo experiments demonstrated that the angular orientation of a stationary inflated valvuloplasty balloon can be measured with precision less than 1 degree. In-vivo pig experiments demonstrated that cardiac motion contributed to measurement variability, with precision less than 3 degrees. Error in specification of x-ray geometry directly influences measurement accuracy. Conclusion: This work demonstrates that the 3D angular orientation of the aortic valve can be calculated precisely from a planar image of a valvuloplasty balloon inflated across the aortic valve and known x-ray geometry. This method could be used to determine appropriate c-arm angular projections during TAVR procedures to minimize x-ray imaging parallax and thereby minimize prosthetic valve positioning errors.« less
Bongert, Markus; Geller, Marius; Pennekamp, Werner; Nicolas, Volkmar
2018-03-03
Diseases of the cardiovascular system account for nearly 42% of all deaths in the European Union. In Germany, approximately 12,000 patients receive surgical replacement of the aortic valve due to heart valve disease alone each year. A three-dimensional (3D) numerical model based on patient-specific anatomy derived from four-dimensional (4D) magnetic resonance imaging (MRI) data was developed to investigate preoperatively the flow-induced impact of mounting positions of aortic prosthetic valves to select the best orientation for individual patients. Systematic steady-state analysis of blood flow for different rotational mounting positions of the valve is only possible using a virtual patient model. A maximum velocity of 1 m/s was used as an inlet boundary condition, because the opening angle of the valve is at its largest at this velocity. For a comparative serial examination, it is important to define the standardised general requirements to avoid impacts other than the rotated implantation of the prosthetic aortic valve. In this study, a uniform velocity profile at the inlet for the inflow of the aortic valve and the real aortic anatomy were chosen for all simulations. An iterative process, with the weighted parameters flow resistance (1), shear stress (2) and velocity (3), was necessary to determine the best rotated orientation. Blood flow was optimal at a 45° rotation from the standard implantation orientation, which will offer a supply to the coronary arteries.
Casarotto, D; Motta, A; Fabbri, A; Pugliese, P; Muneretto, C; Zanini, M; Sheiban, I
1985-04-01
Mechanical complications of prosthetic valves are increasing. The following report describes a case of fracture of a Björk-Shiley mitral prosthetic strut with dislogment of the valve occluder into the thoracic aorta. At the reoperation a new prosthesis was implanted but the patient died of acute heart failure. The diagnosis of valve disfunction must be made non invasively, because the time required for cardiac catherization usually constitutes a lethal delay. The only hope for survival is prompt surgical treatment.
Alternative causes of bioreaction to prosthetic heart valves: three cases with pannus formation.
Karakoyun, Süleyman; Gürsoy, Ozan Mustafa; Kalçık, Macit; Coban Kökten, Sermin; Ozkan, Mehmet
2014-01-01
Pannus formation is an infrequent but serious complication of prosthetic heart valve surgery. The cause of pannus is recognized as a bioreaction to the prostheses; histological investigations have shown that pannus comprises collagen and elastic tissues containing endothelial cells, chronic inflammatory cells, and myofibroblasts. However, the detailed mechanism of its formation has not been fully demonstrated. We aimed to evaluate the potential role of vascular endothelial growth factor (VEGF) and matrix metalloproteinase-2 (MMP-2) in the pathogenesis of pannus formation in three patients with mechanical prosthetic heart valves. Pannus specimens removed from the prostheses were fixed in 10% neutral-buffered formalin for 24 hours after surgical removal and paraffin-embedded using standard procedures. Serial sections were cut at 4 µm for immunohistochemistry analysis. Hematoxylin and eosin (HE) was used in the histological analysis. VEGF and MMP-2 were studied in the immunohistochemistry analysis. Three patients with mechanical prosthetic obstruction due to pannus overgrowth underwent redo valve surgery. In the first and second patients, the mitral prosthesis was explanted along with the pannus overgrowth. The third patient had both aortic and mitral prostheses; the aortic prosthesis was explanted with obstructive pannus formation, whereas the mitral valve was spared with excision of the nonobstructive pannus. The immunohistochemical study demonstrated the expressions of MMP-2 and VEGF in all of the pannus specimens acquired from these cases. VEGF and MMP-2 may play a role in the mechanism of pannus formation as the elements of the chronic active inflammatory process.
Single leg separation prevalence among explanted Björk-Shiley prosthetic heart valves.
Blot, William J; Signorello, Lisa B; Cohen, Sarah S; Ibrahim, Michel A
2007-11-01
Björk-Shiley convexo-concave (BSCC) prosthetic heart valves are believed to have been implanted in over 86,000 patients worldwide. Limited data are available on the prevalence of single leg separations (SLS) of the valves' outlet struts, a potential precursor to complete valve fracture. Data maintained by the manufacturer, including results of examinations for SLS in explanted valves, were merged with available information on the characteristics of the valve. The prevalence of SLS in the examined valves was calculated according to valve angle, size, position, and study. Among 343 examined valves, the overall prevalence of SLS was 8.2%, but this varied significantly by valve size, being three-fold higher among 29+ mm valves than among smaller valves, with statistically non-significantly higher prevalences among mitral than aortic, and among 70 degrees than 60 degrees valves. By applying the size, position and angle-specific SLS prevalences to the worldwide valve distribution, it is estimated that SLS may be present in 6.8% (95% confidence limits 4.1-9.4%) of all BSCC valves. These findings suggest that SLS may affect between 820 and 1,880 of the almost 20,000 BSCC valves among surviving patients worldwide. Such estimates help frame the context for potential patient screenings, should imaging and acoustic techniques to detect SLS become available.
Ueda, Tomohiro; Teshima, Hideki; Fukunaga, Shuji; Aoyagi, Shigeaki; Tanaka, Hiroyuki
2013-01-01
This study was performed to evaluate the diagnostic role of electrocardiographically gated multidetector-row computed tomography (MDCT) for prosthetic valve obstruction (PVO) in the aortic position. Between 2002 and 2006, 9 patients were diagnosed with PVO of an aortic bileaflet mechanical valve based on echocardiographic and cineradiographic criteria. These 9 patients were examined using MDCT before replacement of the mechanical valve, and intraoperative findings were compared to morphologic periprosthetic abnormalities observed on MDCT. CT attenuation (Hounsfield units; HU) of the periprosthetic abnormalities was measured to investigate the underlying cause of the PVO. MDCT showed subprosthetic masses extending beyond the prosthetic ring into the orifice of the valve. At reoperation, presence of subprosthetic pannus was confirmed in all of the 9 patients, but no periprosthetic thrombus was found. The mean CT attenuation of the subprosthetic pannus was 170 HU, and it was significantly greater than that obtained from the interventricular septum (108 HU; P<0.0001). MDCT can be used to clearly visualize subprosthetic pannus causing PVO and the mean CT attenuation of subprosthetic pannus is significantly higher than that of the interventricular septum on MDCT.
Novel imaging strategies for the detection of prosthetic heart valve obstruction and endocarditis.
Tanis, W; Budde, R P J; van der Bilt, I A C; Delemarre, B; Hoohenkerk, G; van Rooden, J-K; Scholtens, A M; Habets, J; Chamuleau, S
2016-02-01
Prosthetic heart valve (PHV) dysfunction remains difficult to recognise correctly by two-dimensional (2D) transthoracic and transoesophageal echocardiography (TTE/TEE). ECG-triggered multidetector-row computed tomography (MDCT), 18-fluorine-fluorodesoxyglucose positron emission tomography including low-dose CT (FDG-PET) and three-dimensional transoesophageal echocardiography (3D-TEE) may have additional value. This paper reviews the role of these novel imaging tools in the field of PHV obstruction and endocarditis.For acquired PHV obstruction, MDCT is of additional value in mechanical PHVs to differentiate pannus from thrombus as well as to dynamically study leaflet motion and opening/closing angles. For biological PHV obstruction, additional imaging is not beneficial as it does not change patient management. When performed on top of 2D-TTE/TEE, MDCT has additional value for the detection of both vegetations and pseudoaneurysms/abscesses in PHV endocarditis. FDG-PET has no complementary value for the detection of vegetations; however, it appears more sensitive in the early detection of pseudoaneurysms/abscesses. Furthermore, FDG-PET enables the detection of metastatic and primary extra-cardiac infections. Evidence for the additional value of 3D-TEE is scarce.As clinical implications are major, clinicians should have a low threshold to perform additional MDCT in acquired mechanical PHV obstruction. For suspected PHV endocarditis, both FDG-PET and MDCT have complementary value.
21 CFR 870.3925 - Replacement heart valve.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Replacement heart valve. 870.3925 Section 870.3925...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3925 Replacement heart valve. (a) Identification. A replacement heart valve is a device intended to perform the function of any...
21 CFR 870.3925 - Replacement heart valve.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Replacement heart valve. 870.3925 Section 870.3925...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3925 Replacement heart valve. (a) Identification. A replacement heart valve is a device intended to perform the function of any...
21 CFR 870.3925 - Replacement heart valve.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Replacement heart valve. 870.3925 Section 870.3925...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3925 Replacement heart valve. (a) Identification. A replacement heart valve is a device intended to perform the function of any...
21 CFR 870.3925 - Replacement heart valve.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Replacement heart valve. 870.3925 Section 870.3925...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3925 Replacement heart valve. (a) Identification. A replacement heart valve is a device intended to perform the function of any...
21 CFR 870.3925 - Replacement heart valve.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Replacement heart valve. 870.3925 Section 870.3925...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3925 Replacement heart valve. (a) Identification. A replacement heart valve is a device intended to perform the function of any...
Three-dimentional simulation of flow-induced platelet activation in artificial heart valves
NASA Astrophysics Data System (ADS)
Hedayat, Mohammadali; Asgharzadeh, Hafez; Borazjani, Iman
2015-11-01
Since the advent of heart valve, several valve types such as mechanical and bio-prosthetic valves have been designed. Mechanical Heart Valves (MHV) are durable but suffer from thromboembolic complications that caused by shear-induced platelet activation near the valve region. Bio-prosthetic Heart Valves (BHV) are known for better hemodynamics. However, they usually have a short average life time. Realistic simulations of heart valves in combination with platelet activation models can lead to a better understanding of the potential risk of thrombus formation in such devices. In this study, an Eulerian approach is developed to calculate the platelet activation in three-dimensional simulations of flow through MHV and BHV using a parallel overset-curvilinear immersed boundary technique. A curvilinear body-fitted grid is used for the flow simulation through the anatomic aorta, while the sharp-interface immersed boundary method is used for simulation of the Left Ventricle (LV) with prescribed motion. In addition, dynamics of valves were calculated numerically using under-relaxed strong-coupling algorithm. Finally, the platelet activation results for BMV and MHV are compared with each other.
Malekzadeh-Milani, Sophie; Ladouceur, Magalie; Cohen, Sarah; Iserin, Laurence; Boudjemline, Younes
2014-11-01
Although widely accepted worldwide, indications for percutaneous valve replacement are limited to treatment of dysfunction of prosthetic conduits inserted in the right ventricular outflow tract (RVOT). There has been little evaluation of the use of the Melody(®) valve for patched non-circular pulmonary pathways. To evaluate the outcomes of Melody valve insertion in patients with a patched non-circular RVOT. We analysed procedural and outcomes data from 34 patients who underwent Melody valve implantation for a non-circular RVOT. RVOT preparation was done in all patients, using different techniques (conventional, Russian doll and/or PA jailing). Melody valve insertion was performed concomitantly in most patients. All procedures were successful. Sixteen patients had complex additional procedures, including the jailing technique (n=5), the Russian doll technique (n=6) and multiple stent implantations (Russian jailing; n=5). The remaining patients were treated using the conventional technique with systematic prestenting. Three early complications occurred: one haemoptysis; one residual RVOT obstruction needing recatheterization 48 hours after percutaneous pulmonary valve implantation; and one stent embolization during advancement of the Ensemble(®) delivery system. The mean follow-up period was 2.6 years postprocedure. There was no stent fracture, migration or embolization. Two patients developed a significant paraprosthetic leak and one received a second Melody valve. Careful patient selection, balloon sizing and RVOT preparation with prestenting are required to create a safe landing zone for the Melody valve. Short-term follow-up shows excellent results with no stent fracture or migration and appears promising. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Dissection of the atrial wall after mitral valve replacement.
Lukács, L; Kassai, I; Lengyel, M
1996-01-01
We describe an unusual sequela of mitral valve replacement in a 50-year-old woman who had undergone a closed mitral commissurotomy in 1975. She was admitted to our hospital because of mitral restenosis in November 1993, at which time her mitral valve was replaced with a mechanical prosthesis. On the 8th postoperative day, the patient developed symptoms of heart failure; transesophageal echocardiography revealed dissection and rupture of the left atrial wall. At prompt reoperation, we found an interlayer dissection and rupture of the atrial wall into the left atrium. We repaired the ruptured atrial wall with a prosthetic patch. The postoperative course was uneventful, and postoperative transesophageal echocardiography showed normal prosthetic valve function and no dissection. Images PMID:8680278
Kaul, Pankaj; Adluri, Krishna; Javangula, Kalyana; Baig, Wasir
2009-01-01
A 59 year old man underwent mechanical tricuspid valve replacement and removal of pacemaker generator along with 4 pacemaker leads for pacemaker endocarditis and superior vena cava obstruction after an earlier percutaneous extraction had to be abandoned, 13 years ago, due to cardiac arrest, accompanied by silent, unsuspected right atrial perforation and exteriorisation of lead. Postoperative course was complicated by tricuspid valve thrombosis and secondary pulmonary embolism requiring TPA thrombolysis which was instantly successful. A review of literature of pacemaker endocarditis and tricuspid thrombosis along with the relevant management strategies is presented. We believe this case report is unusual on account of non operative management of right atrial lead perforation following an unsuccessful attempt at percutaneous removal of right sided infected pacemaker leads and the incidental discovery of the perforated lead 13 years later at sternotomy, presentation of pacemaker endocarditis with a massive load of vegetations along the entire pacemaker lead tract in superior vena cava, right atrial endocardium, tricuspid valve and right ventricular endocardium, leading to a functional and structural SVC obstruction, requirement of an unusually large dose of warfarin postoperatively occasioned, in all probability, by antibiotic drug interactions, presentation of tricuspid prosthetic valve thrombosis uniquely as vasovagal syncope and isolated hypoxia and near instantaneous resolution of tricuspid prosthetic valve thrombosis with Alteplase thrombolysis. PMID:19239701
Acute aortic regurgitation secondary to disk embolization of a Björk-Shiley prosthetic aortic valve.
Grande, Robert D; Katz, William E
2011-03-01
Having passed the 30th anniversary of the first implantation of a Björk-Shiley convexo-concave tilting mechanical valve, recognition of the life-threatening complication of strut fracture is not widespread. The authors report the case of a 48-year-old man with acute-onset chest pain and dyspnea found to have strut fracture and disk embolization of a 26-year-old Björk-Shiley prosthetic aortic valve. The value of echocardiography in the diagnosis of this condition is discussed. Copyright © 2010 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.
Ozkan, Mehmet; Gündüz, Sabahattin; Yildiz, Mustafa; Duran, Nilüfer Eksi
2010-05-01
Prosthetic heart valve obstruction (PHVO) caused by pannus formation is an uncommon but serious complication. Although two-dimensional transesophageal echocardiography (2D-TEE) is the method of choice in the evaluation of PHVO, visualization of pannus is almost impossible with 2D-TEE. While demonstrating the precise aetiology of PHVO is essential for guiding the therapy, either thrombolysis for valve thrombosis or surgery for pannus formation, more sophisticated imaging techniques are needed in patients with suspected pannus formation. We present real-time 3D-TEE imaging in a patient with mechanical mitral PHVO, clearly demonstrating pannus overgrowth.
Fukuta, Yuriko; Yildiz-Aktas, Isil Z; William Pasculle, A; Veldkamp, Peter J
2012-06-01
Legionella endocarditis is extremely uncommon, and embolic phenomena have never been reported. We report the first case of Legionella micdadei prosthetic valve endocarditis complicated by brain abscess. A 57-y-old immunocompromised woman with a history of mitral valve replacement developed confusion and left-sided weakness. Brain magnetic resonance imaging showed a 3-cm peripheral-enhancing mass. Transoesophageal echocardiography suggested a perivalvular abscess. Blood cultures and valve cultures were negative. She was diagnosed with 16S rRNA polymerase chain reaction and silver stain, and was discharged with levofloxacin after a redo mitral valve replacement. Twelve cases of Legionella endocarditis were reviewed. Only one case had a native valve, and her endocarditis occurred after pneumonia. All cases were cured. The duration of antibiotic therapy was variable. Legionella species should be considered in the differential diagnosis of culture-negative endocarditis in both immunocompetent and immunocompromised patients. Molecular techniques and silver impregnation stains are useful, especially when cultures using buffered charcoal-yeast extract agar are negative.
Outlet strut fracture and leaflet escape of Bjork-Shiley convexo-concave valve.
Uchino, Gaku; Yoshida, Hideo; Sakoda, Naoya; Hattori, Shigeru; Kawabata, Takuya; Saiki, Munehiro; Fujita, Yasufumi; Yunoki, Keiji; Hisamochi, Kunikazu; Mine, Yoshinari
2017-06-01
Prosthetic valve fracture is a serious complication and may arise in patient post-valve replacement. We experienced an outlet strut fracture and leaflet escape of a Bjork-Shiley convexo-concave valve. We performed an emergency redo mitral valve replacement and successfully retrieved the fractured strut and escaped leaflet from superficial femoral artery and the abdominal aorta. The patient showed an uneventful postoperative recovery.
MANAGEMENT OF FAILED MITRAL VALVE REPLACEMENT. THE DURBAN EXPERIENCE.
Kistan, D; Booysen, M; Alexander, G; Madiba, T E
2017-06-01
Mitral valve replacement is the procedure of choice in patients with severe mitral valve disease. However, these patients are surviving longer and are thus at an increased risk of prosthesis failure or valve-related complications. Study setting: Inkosi Albert Luthuli Central Hospital, a tertiary referral Hospital in Durban. Study population: All patients undergoing redo mechanical mitral valve replacement surgery between January 2005 and December 2014. Study design: Retrospective analysis of patients undergoing redo mitral valve replacement. Patients were identified from theatre record books, their files were electronically accessed and pertinent information extracted onto a data capture sheet. Information documented included demographics, duration to failure, INR, Albumin, HIV status, clinical findings and outcome. The data was stored on an Excel datasheet. Fifty-eight patients were documented (mean age 32 ± 15.81 years; M:F 1:3). Ten patients (17%) were HIV positive (median CD4 count 478). Mean duration between first surgery and redo was 8.8 years. Thirty-five patients (60%) had no co-morbidities. Presenting features at redo surgery were congestive cardiac failure (27), chest pain (11) and palpitations (17). Mean preoperative Ejection Fraction was 51.65 %. Twenty-nine patients (55%) had emergency redo surgery. Twenty-two patients (75%) had acute prosthetic valve thrombosis. Thirty-two patients had tricuspid regurgitation. Original pathology was documented in 23 patients (40%) as Rheumatic valve disease. Prosthetic valve thrombosis was documented in 31 patients (54%). The most commonly used valve was the On-X. Mean presenting INR was 1.96 + 1.2 and mean presenting serum albumin was 36.7 + 7.8 g/l. Forty-one patients (71%) were found to be compliant to Warfarin therapy prior to redo surgery. Mean ICU stay was 6 +9 days. Two patients died postoperatively. Mean followup was 32 + 26.6 months. Twelve patients (20.7%) developed postoperative complications. Patients were younger than world literature suggests. Rheumatic heart disease was the common underlying pathology. Prosthetic valve thrombosis was common. More than half had emergency surgery. Mortality rate was negligible.
Achromobacter species endocarditis: A case report and literature review
Derber, Catherine; Elam, Kara; Forbes, Betty A; Bearman, Gonzalo
2011-01-01
Endocarditis due to Achromobacter species is a rare, yet serious, endovascular infection. Achromobacter species infective endocarditis is associated with underlying immunodeficiencies or prosthetic heart valves and devices. A case of prosthetic pulmonary valve endocarditis secondary to Achromobacter xylosoxidans subspecies denitrificans is described in the present report. This life-threatening infection was successfully treated with combined valve replacement and prolonged antibiotic therapy. A Medline/PubMed literature review of Achromobacter endocarditis was also performed. Achromobacter species are an uncommon, yet important, cause of nosocomial endocarditis. Given the significant associated morbidity and mortality, along with a high degree of intrinsic antibiotic resistance, Achromobacter species infective endocarditis remains a clinical treatment challenge. PMID:22942890
Fungal prosthetic valve endocarditis with mycotic aneurysm: Case report.
Brandão, Mariana; Almeida, Jorge; Ferraz, Rita; Santos, Lurdes; Pinho, Paulo; Casanova, Jorge
2016-09-01
Fungal prosthetic valve endocarditis is an extremely severe form of infective endocarditis, with poor prognosis and high mortality despite treatment. Candida albicans is the most common etiological agent for this rare but increasingly frequent condition. We present a case of fungal prosthetic valve endocarditis due to C. albicans following aortic and pulmonary valve replacement in a 38-year-old woman with a history of surgically corrected tetralogy of Fallot, prior infective endocarditis and acute renal failure with need for catheter-based hemodialysis. Antifungal therapy with liposomal amphotericin B was initiated prior to cardiac surgery, in which the bioprostheses were replaced by homografts, providing greater resistance to recurrent infection. During hospitalization, a mycotic aneurysm was diagnosed following an episode of acute arterial ischemia, requiring two vascular surgical interventions. Despite the complications, the patient's outcome was good and she was discharged on suppressive antifungal therapy with oral fluconazole for at least a year. The reported case illustrates multiple risk factors for fungal endocarditis, as well as complications and predictors of poor prognosis, demonstrating its complexity. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.
Prosthetic Tricuspid Valve Thrombosis: Three Case Reports and Literature Review
Yaminisharif, Ahmad; Alemzadeh-Ansari, Mohammad Javad; Ahmadi, Seyed Hossein
2012-01-01
A common complication of prosthetic heart valves is thrombosis. Although the incidence of prosthetic valve thrombosis (PVT) in the tricuspid position is high, there are not enough data on the management of it, in contrast to left-sided PVT. Here, we describe three cases of tricuspid PVT with three different management approaches: thrombolytic therapy; close observation with oral anticoagulants; and surgery. The first case was a woman who suffered from recurrent PVT, for which we successfully used Tenecteplase for second and third episodes. We employed Tenecteplase in this case for the first time in the therapy of tricuspid PVT. The second case had fixed leaflets in open position while being symptomless. At six months' follow-up, with the patient having taken oral anticoagulants, the motion of the leaflets was restricted and she was symptomfree. The last case was a woman who had a large thrombus in the right atrium immediately after mitral and tricuspid valvular replacement. The patient underwent re-replacement surgery and a new biological valve was implanted in the tricuspid position. Also, we review the literature on the pathology, signs and symptoms, diagnosis, and management of tricuspid PVT. PMID:23323074
Kannan, Arun; Jahan, Kahroba; Lotun, Kapildeo; Janardhanan, Rajesh
2015-09-21
Acute prosthetic valve thrombosis is a potentially serious complication with an incidence as high as 6% per patient-year for prostheses in the mitral position. Accurate diagnosis of the degree of obstruction and differentiation of pannus versus thrombus is critical in determination of the best mode of therapy. We discuss a case of a patient with multiple comorbidities who presented with mechanical mitral valve obstruction where both transthoracic and two-dimensional transesophageal echocardiography (TEE) were limited in making an accurate diagnosis regarding the mechanism of obstruction. Real-time 3D-TEE (RT-3DTEE) was critical in identifying a partial thrombus on the mechanical valve and guided the choice of thrombolysis as the most appropriate intervention, thus avoiding high-risk surgery in this patient with significant multiple comorbidities. 2015 BMJ Publishing Group Ltd.
Kannan, Arun; Jahan, Kahroba; Lotun, Kapildeo; Janardhanan, Rajesh
2015-01-01
Acute prosthetic valve thrombosis is a potentially serious complication with an incidence as high as 6% per patient-year for prostheses in the mitral position. Accurate diagnosis of the degree of obstruction and differentiation of pannus versus thrombus is critical in determination of the best mode of therapy. We discuss a case of a patient with multiple comorbidities who presented with mechanical mitral valve obstruction where both transthoracic and two-dimensional transesophageal echocardiography (TEE) were limited in making an accurate diagnosis regarding the mechanism of obstruction. Real-time 3D-TEE (RT-3DTEE) was critical in identifying a partial thrombus on the mechanical valve and guided the choice of thrombolysis as the most appropriate intervention, thus avoiding high-risk surgery in this patient with significant multiple comorbidities. PMID:26392458
Vent-induced prosthetic leaflet thrombosis treated by open-heart valve-in-valve implantation.
Stamm, Christof; Pasic, Miralem; Buz, Semih; Hetzer, Roland
2015-09-01
A patient required emergency mitral valve replacement and extracorporeal membrane oxygenation (ECMO) support for acute biventricular failure. The left ventricular (LV) vent inserted via the left upper pulmonary vein induced thrombotic immobilization of a prosthetic valve leaflet, with significant intra-prosthesis regurgitation after ECMO explantation. Therefore, the left atrium was opened on the beating heart during conventional extracorporeal circulation, all prosthesis leaflets were excised and a 29-mm expandable Edwards Sapien prosthesis was inserted within the scaffold of the original prosthesis under direct vision. This case illustrates the benefits and potential problems of LV venting on ECMO support, and a rapid and safe way of replacing the prosthesis leaflets in a critical situation. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Patient Management with Metallic Valve Prosthesis during Pregnancy and Postpartum Period.
Garcez, Juliane Dantas Seabra; Rosa, Vitor Emer Egypto; Lopes, Antonio Sergio de Santis Andrade; Accorsi, Tarso Augusto Duenhas; Fernandes, João Ricardo Cordeiro; Pomerantzeff, Pablo Maria; Avila, Walkiria Samuel; Tarasoutchi, Flavio
2015-10-01
Prosthetic thrombosis is a rare complication, but it has high mortality and morbidity. Young women of childbearing age that have prosthetic heart valves are at increased risk of thrombosis during pregnancy due to changes in coagulation factors. Anticoagulation with adequate control and frequent follow-up if pregnancy occurs must be performed in order to prevent complications related to anticoagulant use. Surgery remains the treatment of choice for prosthetic heart valve thrombosis in most clinical conditions. Patients with metallic prosthetic valves have an estimated 5% risk of thrombosis during pregnancy and maternal mortality of 1.5% related to the event. Anticoagulation with vitamin K antagonists during pregnancy is related to varying degrees of complications at each stage of the pregnancy and postpartum periods. Warfarin sodium crosses the placental barrier and when used in the first trimester of pregnancy is a teratogenic agent, causing 1-3% of malformations characterized by fetal warfarin syndrome and also constitutes a major cause of miscarriage in 10-30% of cases. In the third trimester and at delivery, the use of warfarin is associated with maternal and neonatal bleeding in approximately 5 to 15% of cases, respectively. On the other hand, inadequate anticoagulation, including the suspension of the oral anticoagulants aiming at fetal protection, carries a maternal risk of about 25% of metallic prosthesis thrombosis, particularly in the mitral valve. This fact is also due to the state of maternal hypercoagulability with activation of coagulation factors V, VI, VII, IX, X, platelet activity and fibrinogen synthesis, and decrease in protein S levels. The Registry of Pregnancy and Cardiac Disease (ROPAC), assessing 212 pregnant women with metal prosthesis, showed that prosthesis thrombosis occurred in 10 (4.7%) patients and maternal hemorrhage in 23.1%, concluding that only 58% of patients with metallic prosthesis had a complication-free pregnancy.
D'Avenio, Giuseppe; Grigioni, Mauro; Daniele, Carla; Morbiducci, Umberto; Hamilton, Kathrin
2015-01-01
Prosthetic heart valves can be associated to mechanical loading of blood, potentially linked to complications (hemolysis and thrombogenicity) which can be clinically relevant. In order to test such devices in pulsatile mode, pulse duplicators (PDs) have been designed and built according to different concepts. This study was carried out to compare anemometric measurements made on the same prosthetic device, with two widely used PDs. The valve (a 27-mm bileaflet valve) was mounted in the aortic section of the PD. The Sheffield University PD and the RWTH Aachen PD were selected as physical models of the circulation. These two PDs differ mainly in the vertical vs horizontal realization, and in the ventricular section, which in the RWTH PD allows for storage of potential energy in the elastic walls of the ventricle. A glassblown aorta, realized according to the geometric data of the same anatomical district in healthy individuals, was positioned downstream of the valve, obtaining 1:1 geometric similarity conditions. A NaI-glycerol-water solution of suitable kinematic viscosity and, at the same time, the proper refractive index, was selected. The flow field downstream of the valve was measured by means of the stereo-PIV (Particle Image Velocimetry) technique, capable of providing the complete 3D velocity field as well as the entire Reynolds stress tensor. The measurements were carried out at the plane intersecting the valve axis. A three-jet profile was clearly found in the plane crossing the leaflets, with both PDs. The extent of the typical recirculation zone in the Valsalva sinus was much larger in the RWTH PD, on account of the different duration of the swirling motion in the ventricular chamber, caused by the elasticity of the ventricle and its geometry. The comparison of the hemodynamical behaviour of the same bileaflet valve tested in two PDs demonstrated the role of the mock loop in affecting the valve performance.
Greiten, Lawrence E; McKellar, Stephen H; Rysavy, Joseph; Schaff, Hartzell V
2014-05-01
Warfarin is used to reduce the risk of stroke and thromboembolic complications in patients with mechanical heart valves. Yet, despite frequent blood testing, its poor pharmacokinetic and pharmacodynamic profiles often result in variable therapeutic levels. Rivaroxaban is a direct competitive factor Xa inhibitor that is taken orally. It inhibits the active site of factor Xa without the need for the cofactor antithrombin, and thus, its mechanism of action is differentiated from that of the fractionated heparins and indirect factor Xa inhibitors. No in vivo data exist regarding the effectiveness of rivaroxaban in preventing thromboembolic complications of mechanical heart valves. We tested the hypothesis that rivaroxaban is as effective as enoxaparin for thromboprophylaxis of mechanical valves that use a previously described heterotopic aortic valve porcine model. A modified bileaflet mechanical valved conduit that bypassed the native, ligated descending thoracic aorta was implanted into 30 swine. Postoperatively, the animals were randomly assigned to groups receiving no anticoagulation (n = 10), enoxaparin at 2 mg/kg subcutaneously twice daily (n = 10) or rivaroxaban at 2 mg/kg orally twice daily (n = 10). The amount of valve thrombus was measured on post-implantation day 30 as the primary end point. Quantitative evaluation of radiolabelled platelet deposition on the valve prostheses was done and embolic and haemorrhagic events were measured as secondary end points. Animals with no anticoagulation had a thrombus mean of 759.9 mg compared with 716.8 mg with enoxaparin treatment and 209.6 mg with rivaroxaban treatment (P = 0.05 for enoxaparin vs rivaroxaban). Similarly, the mean number of platelets deposited on the valve prosthesis was lower in the rivaroxaban group (6.13 × 10(9)) than in the enoxaparin group (3.03 × 10(10)) (P = 0.03). In this study, rivaroxaban was more effective than enoxaparin for short-term thromboprophylaxis of mechanical valve prosthetics in the heterotopic aortic position. It reduced valve thrombus and platelet deposition on day 30 following implantation without increased adverse events. Future studies would provide additional support for clinical trials evaluating rivaroxaban as an alternative to warfarin for appropriately selected patients with prosthetic aortic valves.
Jahandardoost, Mehdi; Fradet, Guy; Mohammadi, Hadi
2016-03-01
To date, to the best of the authors' knowledge, in almost all of the studies performed around the hemodynamics of bileaflet mechanical heart valves, a heart rate of 70-72 beats/min has been considered. In fact, the heart rate of ~72 beats/min does not represent the entire normal physiological conditions under which the aortic or prosthetic valves function. The heart rates of 120 or 50 beats/min may lead to hemodynamic complications, such as plaque formation and/or thromboembolism in patients. In this study, the hemodynamic performance of the bileaflet mechanical heart valves in a wide range of normal and physiological heart rates, that is, 60-150 beats/min, was studied in the opening phase. The model considered in this study was a St. Jude Medical bileaflet mechanical heart valve with the inner diameter of 27 mm in the aortic position. The hemodynamics of the native valve and the St. Jude Medical valve were studied in a variety of heart rates in the opening phase and the results were carefully compared. The results indicate that peak values of the velocity profile downstream of the valve increase as heart rate increases, as well as the location of the maximum velocity changes with heart rate in the St. Jude Medical valve model. Also, the maximum values of shear stress and wall shear stresses downstream of the valve are proportional to heart rate in both models. Interestingly, the maximum shear stress and wall shear stress values in both models are in the same range when heart rate is <90 beats/min; however, these values significantly increase in the St. Jude Medical valve model when heart rate is >90 beats/min (up to ~40% growth compared to that of the native valve). The findings of this study may be of importance in the hemodynamic performance of bileaflet mechanical heart valves. They may also play an important role in design improvement of conventional prosthetic heart valves and the design of the next generation of prosthetic valves, such as percutaneous valves. © IMechE 2016.
Wilkins, G T; Gillam, L D; Kritzer, G L; Levine, R A; Palacios, I F; Weyman, A E
1986-10-01
For patients with stenotic native valves, the modified Bernoulli equation (delta P = 4V2) may be applied to Doppler-measured transvalvular velocities to yield an accurate estimate of transvalvular gradients. Although it would be useful if the same approach could be used for those with stenotic prosthetic valves, no previous study has validated the Doppler technique in this setting. We therefore recorded simultaneous continuous-wave Doppler flow profiles and transvalvular manometric gradients in 12 catheterized patients in whom all atrial and ventricular pressures were directly measured (transseptal left atrial catheterization and transthoracic ventricular puncture were performed where necessary). A total of 13 prostheses were studied: 11 mitral (seven porcine, three Starr-Edwards, and one Björk-Shiley) and two tricuspid (one porcine and one Björk-Shiley). The Doppler-determined mean gradient was calculated as the mean of the instantaneous gradients (delta P = 4V2) at 10 msec intervals throughout diastole. The correlation of simultaneous Doppler (DMG) and manometric mean gradients (MG) for the whole group (n = 13) demonstrated a highly significant relationship (MG = 1.07 DMG + 0.28; r = .96, p = .0001). The correlation was equally good for porcine valves alone (n = 8) (MG = 1.06 DMG + 0.55; r = .96, p = .001) and for mechanical valves alone (n = 5) (MG = 1.06 DMG - 0.04; r = .93, p = .02). In a subset of patients without regurgitation (n = 8), prosthetic valve areas were estimated by two Doppler methods originally described by Holen and Hatle, as well as by the invasive Gorlin method. As expected from theoretical considerations, a close correlation was not demonstrated between results of the Gorlin method and those of either Hatle's Doppler method (r = .65, fp = NS) or Holen's method (r = .14, p = NS). Comparison of the results of the two Doppler methods yielded a somewhat closer correlation (r = .73, p less than or equal to .05). These results suggest that in patients with disk-occluder, ball-occluder, and porcine prosthetic valves, Doppler estimates of transvalvular gradients are virtually identical to those obtained invasively.
Gürsoy, Mustafa Ozan; Kalçik, Macit; Karakoyun, Süleyman; Özkan, Mehmet
2015-01-01
Prosthetic valve thrombosis (PVT) is a potentially life-threatening complication of heart valve replacement. Early diagnosis is crucial for the prevention of significantly morbid and lethal complications. Cinefluoroscopy (CF) and echocardiography have been widely used for diagnosing PVT. In recent years, the role of CF has declined since the introduction of transesophageal echocardiography and the great improvements in ultrasound technology including real time three-dimensional imaging. Nevertheless, both echocardiography and CF provide different kinds of information on prosthesis function, and therefore they are considered as complementary and not alternative. In this review, we aimed to summarize the current status of CF and echocardiography in the diagnosis of PVT. © 2014, Wiley Periodicals, Inc.
Potpara, Tatjana S; Lip, Gregory Y H; Larsen, Torben B; Madrid, Antonio; Dobreanu, Dan; Jędrzejczyk-Patej, Ewa; Dagres, Nikolaos
2016-10-01
The purpose of this European Heart Rhythm Association (EHRA) Survey was to assess the perceptions of 'valvular' atrial fibrillation (AF) and management of AF patients with various heart valve abnormalities in daily clinical practice in European electrophysiology (EP) centres. Questionnaire survey was sent via the Internet to the EHRA-EP Research Network Centres. Of the 52 responding centres, 42 (80.8%) were university hospitals. Choosing the most comprehensive definition of valvular AF, a total of 49 centres (94.2%) encountered a mechanical prosthetic heart valve and significant rheumatic mitral stenosis, 35 centres (67.3%) also considered bioprosthetic valves, and 25 centres (48.1%) included any significant valvular heart disease, requiring surgical repair in the definition of valvular AF. Only three centres (5.8%) would define valvular AF as the presence of any (even mild) valvular abnormality. None of the centres would use non-vitamin K antagonist oral anticoagulants (NOACs) in AF patients with mechanical prosthetic valves, only 5 centres (9.8%) would use NOACs in patients with significant mitral stenosis, 17 centres (32.7%) would consider the use of NOACs in patients with bioprosthetic valves, and 21 centres (41.2%) would use NOACs in patients with a non-recent transcatheter valve replacement/implantation, while 13 centres (25.5%) would never consider the use of NOACs in AF patients with even mild native heart valve abnormality. Our survey showed marked heterogeneity in the definition of valvular AF and thromboprophylactic treatments, with the use of variable NOACs in patients with valvular heart disease other than prosthetic heart valves or significant mitral stenosis, indicating that this term may be misleading and should not be used. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Application of color Doppler flow mapping to calculate orifice area of St Jude mitral valve
NASA Technical Reports Server (NTRS)
Leung, D. Y.; Wong, J.; Rodriguez, L.; Pu, M.; Vandervoort, P. M.; Thomas, J. D.
1998-01-01
BACKGROUND: The effective orifice area (EOA) of a prosthetic valve is superior to transvalvular gradients as a measure of valve function, but measurement of mitral prosthesis EOA has not been reliable. METHODS AND RESULTS: In vitro flow across St Jude valves was calculated by hemispheric proximal isovelocity surface area (PISA) and segment-of-spheroid (SOS) methods. For steady and pulsatile conditions, PISA and SOS flows correlated with true flow, but SOS and not PISA underestimated flow. These principles were then used intraoperatively to calculate cardiac output and EOA of newly implanted St Jude mitral valves in 36 patients. Cardiac output by PISA agreed closely with thermodilution (r=0.91, Delta=-0.05+/-0.55 L/min), but SOS underestimated it (r=0.82, Delta=-1.33+/-0.73 L/min). Doppler EOAs correlated with Gorlin equation estimates (r=0.75 for PISA and r=0.68 for SOS, P<0.001) but were smaller than corresponding in vitro EOA estimates. CONCLUSIONS: Proximal flow convergence methods can calculate forward flow and estimate EOA of St Jude mitral valves, which may improve noninvasive assessment of prosthetic mitral valve obstruction.
Kotaskova, Iva; Nemec, Petr; Vanerkova, Martina; Malisova, Barbora; Tejkalova, Renata; Orban, Marek; Zampachova, Vita; Freiberger, Tomas
2017-08-14
The presence of more than one bacterial agent is relatively rare in infective endocarditis, although more common in prosthetic cases. Molecular diagnosis from a removed heart tissue is considered a quick and effective way to diagnose fastidious or intracellular agents. Here we describe the case of postpartum polymicrobial prosthetic valve endocarditis in a young woman. Sneathia sanguinegens and Mycoplasma hominis were simultaneously detected from the heart valve sample using broad range 16S rRNA polymerase chain reaction (PCR) followed by sequencing while culture remained negative. Results were confirmed by independent PCR combined with denaturing gradient gel electrophoresis. Before the final agent identification, the highly non-compliant patient left from the hospital against medical advice on empirical intravenous treatment with aminopenicillins, clavulanate and gentamicin switched to oral amoxycillin and clavulanate. Four months after surgery, no signs of inflammation were present despite new regurgitation and valve leaflet flail was detected. However, after another 5 months the patient died from sepsis and recurrent infective endocarditis of unclarified etiology. Mycoplasma hominis is a rare causative agent of infective endocarditis. To the best of our knowledge, presented case is the first report of Sneathia sanguinegens detected in this condition. Molecular techniques were shown to be useful even in polymicrobial infective endocarditis samples.
Gulino, Simona; Barbanti, Marco; Deste, Wanda; Immè, Sebastiano; Aruta, Patrizia; Bottari, Vera; Benvenuto, Emanuele; Tamburino, Claudia; Di Landro, Alessio; Liberto, Daria; Santonoceto, Letizia; Sicuso, Rita; Di Stefano, Daniele; Todaro, Denise; Di Simone, Emanuela; Indelicato, Antonino; Giannazzo, Daniela; Sgroi, Carmelo; Tamburino, Corrado
2016-10-10
Long-term data on the durability of currently available transcatheter heart valves are limited. We sought to assess four-year clinical and echocardiographic outcomes in patients undergoing transcatheter aortic valve implantation (TAVI) with the CoreValve prosthesis. Between June 2007 and February 2014, 450 consecutive patients with symptomatic severe aortic stenosis underwent TAVI in our institution. For the purposes of this study, we included only those patients undergoing successful TAVI with the CoreValve prosthesis who had a minimum follow-up of four years (n=125). Survival rates at one, two, three and four years were 83.2, 76.8, 73.6 and 66.3%, respectively. Aortic regurgitation was a common finding after the procedure, especially due to paravalvular regurgitation (PVR), which was observed in the majority of patients (71.5%), mostly mild (52.0%). Progression from mild acute PVR to moderate PVR at four-year follow-up was reported in three patients. No cases of severe PVR were observed. Prosthetic valve failure was reported in four patients (3.2%). Our study demonstrates that favourable outcomes after successful TAVI are associated with sustained clinical and functional cardiovascular benefits up to four-year follow-up. Signs of moderate prosthetic valve failure are present only in a small percentage of patients.
Process and Outcome Study of Multidisciplinary Prosthetic Treatment for Velopharyngeal Dysfunction
ERIC Educational Resources Information Center
Sell, Debbie; Mars, Michael; Worrell, Emma
2006-01-01
Background: A prosthetic approach to velopharyngeal dysfunction (VPD) is not new. However, a collaborative interdisciplinary team approach by a speech-and-language therapist, dental specialist and maxillofacial technician, including accurate fitting using nasendoscopy, has provided an opportunity to define the clinical care pathway, and audit the…
Salmonella species group B causing endocarditis of the prosthetic mitral valve.
Al-Sherbeeni, Nisreen M
2009-08-01
The Salmonella species is an extremely rare cause of infective endocarditis. This case report is for Salmonella spp. group B proven by positive multiple blood cultures, and positive intraoperative culture from the vegetation of the mitral valve prosthesis.
Prosthetic valve endocarditis.
Moore-Gillon, J; Eykyn, S J; Phillips, I
1983-01-01
During 1965 to 1982, 32 episodes of infective endocarditis on prosthetic valves in 30 patients were treated at this hospital. In early endocarditis (presenting within four months of operation) staphylococci were the organisms most commonly responsible. Early endocarditis appears to be declining in incidence and is largely preventable; sternal sepsis was the main predisposing factor, requiring urgent and effective treatment. Streptococci were the most common organisms in late onset disease, but as with natural valve endocarditis a wide range or organisms was responsible. All but one of the patients with early onset disease were treated conservatively, but mortality was high; prompt surgical replacement of infected prostheses is probably indicated in such patients. Medical management was effective in most patients with late onset disease, and for them early surgical intervention may not be justified. PMID:6412805
Strut fracture in a Bjork-Shiley aortic valve prosthesis.
Lifschultz, B D; Donoghue, E R
1985-10-01
Strut fracture can be a life-threatening adverse effect of mechanical prosthetic heart valves. This complication has occurred in the DeBakey, the Beall, the Cooley-Cutter and, most recently, the Bjork-Shiley valves. We report the case of a 35-year-old man who died suddenly 16 months after a 60 degree Bjork-Shiley Convexo-Concave heart valve prosthesis was inserted in the aortic position. At autopsy, the two welded attachments of the valve's outlet strut had fractured. The valve's tilting disc was found in his abdominal aorta.
Survival following fracture of strut from mitral prosthesis with disc translocation.
McEnany, M T; Wheeler, E O; Austen, W G
1979-07-01
Mechanical complications of prosthetic valves are increasingly rare. The acute, catastrophic nature of the symptoms associated with massive transvalvular regurgitation preclude survival except with immediate operation. In the patient described herein, two weld fractures of a Björk-Shiley mitral prosthetic strut led to displacement of the valve occluder into the left atrium. The patient survived reoperation, following which the strut was detected radiologically in the left ventricular free wall. A slow, limited recovery resulted from his 5 preoperative hours of deep shock and coma. No complication attributable to the retained ventricular foreign body has been identified.
Brody, Sarah; Anilkumar, Thapasimuthu; Liliensiek, Sara; Last, Julie A; Murphy, Christopher J; Pandit, Abhay
2006-02-01
A fully effective prosthetic heart valve has not yet been developed. A successful tissue-engineered valve prosthetic must contain a scaffold that fully supports valve endothelial cell function. Recently, topographic features of scaffolds have been shown to influence the behavior of a variety of cell types and should be considered in rational scaffold design and fabrication. The basement membrane of the aortic valve endothelium provides important parameters for tissue engineering scaffold design. This study presents a quantitative characterization of the topographic features of the native aortic valve endothelial basement membrane; topographical features were measured, and quantitative data were generated using scanning electron microscopy (SEM), atomic force microscopy (AFM), transmission electron microscopy (TEM), and light microscopy. Optimal conditions for basement membrane isolation were established. Histological, immunohistochemical, and TEM analyses following decellularization confirmed basement membrane integrity. SEM and AFM photomicrographs of isolated basement membrane were captured and quantitatively analyzed. The basement membrane of the aortic valve has a rich, felt-like, 3-D nanoscale topography, consisting of pores, fibers, and elevations. All features measured were in the sub-100 nm range. No statistical difference was found between the fibrosal and ventricular surfaces of the cusp. These data provide a rational starting point for the design of extracellular scaffolds with nanoscale topographic features that mimic those found in the native aortic heart valve basement membrane.
BRODY, SARAH; ANILKUMAR, THAPASIMUTHU; LILIENSIEK, SARA; LAST, JULIE A.; MURPHY, CHRISTOPHER J.; PANDIT, ABHAY
2016-01-01
A fully effective prosthetic heart valve has not yet been developed. A successful tissue-engineered valve prosthetic must contain a scaffold that fully supports valve endothelial cell function. Recently, topographic features of scaffolds have been shown to influence the behavior of a variety of cell types and should be considered in rational scaffold design and fabrication. The basement membrane of the aortic valve endothelium provides important parameters for tissue engineering scaffold design. This study presents a quantitative characterization of the topographic features of the native aortic valve endothelial basement membrane; topographical features were measured, and quantitative data were generated using scanning electron microscopy (SEM), atomic force microscopy (AFM), transmission electron microscopy (TEM), and light microscopy. Optimal conditions for basement membrane isolation were established. Histological, immunohistochemical, and TEM analyses following decellularization confirmed basement membrane integrity. SEM and AFM photomicrographs of isolated basement membrane were captured and quantitatively analyzed. The basement membrane of the aortic valve has a rich, felt-like, 3-D nanoscale topography, consisting of pores, fibers, and elevations. All features measured were in the sub-100 nm range. No statistical difference was found between the fibrosal and ventricular surfaces of the cusp. These data provide a rational starting point for the design of extracellular scaffolds with nanoscale topographic features that mimic those found in the native aortic heart valve basement membrane. PMID:16548699
Suh, Young Joo; Kim, Young Jin; Kim, Jin Young; Chang, Suyon; Im, Dong Jin; Hong, Yoo Jin; Choi, Byoung Wook
2017-11-01
We aimed to determine the effect of a whole-heart motion-correction algorithm (new-generation snapshot freeze, NG SSF) on the image quality of cardiac computed tomography (CT) images in patients with mechanical valve prostheses compared to standard images without motion correction and to compare the diagnostic accuracy of NG SSF and standard CT image sets for the detection of prosthetic valve abnormalities. A total of 20 patients with 32 mechanical valves who underwent wide-coverage detector cardiac CT with single-heartbeat acquisition were included. The CT image quality for subvalvular (below the prosthesis) and valvular regions (valve leaflets) of mechanical valves was assessed by two observers on a four-point scale (1 = poor, 2 = fair, 3 = good, and 4 = excellent). Paired t-tests or Wilcoxon signed rank tests were used to compare image quality scores and the number of diagnostic phases (image quality score≥3) between the standard image sets and NG SSF image sets. Diagnostic performance for detection of prosthetic valve abnormalities was compared between two image sets with the final diagnosis set by re-operation or clinical findings as the standard reference. NG SSF image sets had better image quality scores than standard image sets for both valvular and subvalvular regions (P < 0.05 for both). The number of phases that were of diagnostic image quality per patient was significantly greater in the NG SSF image set than standard image set for both valvular and subvalvular regions (P < 0.0001). Diagnostic performance of NG SSF image sets for the detection of prosthetic abnormalities (20 pannus and two paravalvular leaks) was greater than that of standard image sets (P < 0.05). Application of NG SSF can improve CT image quality and diagnostic accuracy in patients with mechanical valves compared to standard images. Copyright © 2017 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
Rapid pannus formation after few months of obstructing aortic mechanical prosthesis.
Al-Alao, Bassel; Simoniuk, Urszula; Heron, Brian; Parissis, Haralabos
2015-11-01
We report a rare case of a prosthetic aortic valve obstruction due to pannus formation only 3 months following aortic and mitral valve replacement. Fragments of asymmetrical pannus formation affected one of the leaflets of the bi-leaflet mechanical valve; the leaflet appeared immobile due to pannus ingrowth into the mechanical skeleton resulting in encroachment of the leaflet, which in turn became immobile. The patient successfully underwent emergency redo-aortic valve replacement.
[Indications for and clinical outcome of the Ross procedure: a review].
Morita, K; Kurosawa, H
2001-04-01
The Ross procedure has been used increasingly to treat aortic valve disease in children and young adults. The primary indication for the Ross procedure is to provide a permanent valve replacement in children with congenital aortic stenosis. More recently, it has been extended to young adults with a bicuspid aortic valve and small aortic annulus, especially women wishing to have children. Other possible indications include complex left ventricular outflow obstructive disease, native or prosthetic valve endocarditis, and adult aortic insufficiency with a dilated aortic annulus. Conversely, Marfan syndrome is considered to an absolute contraindication, and this procedure should be used with caution in patients with rheumatic valve disease and a dysplastic dilated aortic root because of the higher associated incidence of autograft dysfunction. The technique of total aortic root replacement has become the preferred method of autograft implantation, because it carries the lowest risk of pulmonary autograft failure. In patients with marked graft-host size mismatch, either concomitant aortic annulus reduction and fixation or aortic annulus enlargement (i.e., the Ross-Konno procedure) should be performed. The Ross Procedure International Registry data document that in the modern era (post-1986) the early and late mortality rate is 2.5% and 1%, respectively. Excellent long-term results have been reported, and the benefits of this procedure include optimal hemodynamics, low risk of endocarditis, resistance to infection in patients with active endocarditis, and nonthrombogeneicity and therefore few anticoagulation-related complications. The Ross procedure can be performed with acceptable early and mid-term mortality and excellent autograft durability. Further long-term follow-up will confirm the role of this procedure in patients with various types of aortic valve disease.
Paci, Anna Maria; Lattanzi, Fabio; Cabani, Enrico; Conti, Umberto; De Tommasi, Salvatore Mario
2007-04-01
Non-obstructive prosthetic valve thrombosis is a rare and underestimated complication in patients with left-sided mechanical heart valves. Systemic embolisation, mainly involving the cerebral circulation, often represents the first clinical manifestation. We report a case of multiple, successive embolizations in the coronary and cerebral circulation, presenting with an acute myocardial infarction and stroke in a patient with latent, non-obstructive thrombosis of a mechanical bileaflet aortic valve. Because of scheduled urological surgery, chronic vitamin K antagonist treatment had previously been discontinued and replaced with low-molecular-weight heparin, at inadequate dosage. Following coronary arteriography, brain computed tomography scan and transoesophageal echocardiography, thrombolysis was performed successfully. This case emphasises the utility of performing transoesophageal echocardiography routinely in the presence of ischaemic signs in patients with mechanical heart valves. In patients requiring discontinuation of oral anticoagulant therapy, accurate management and continuous monitoring of alternative medications are needed in order to avoid severe thromboembolic complications.
Sakamoto, Yoshimasa; Hashimoto, Kazuhiro; Okuyama, Hiroshi; Ishii, Shinichi; Shingo, Taguchi; Kagawa, Hiroshi
2006-01-01
Pannus formation after aortic valve replacement is not common, but obstruction due to chronic pannus is one of the most serious complications of valve replacement. The causes of pannus formation are still unknown and effective preventive methods have not been fully elucidated. We reviewed our clinical experience of all patients who underwent reoperation for prosthetic aortic valve obstruction due to pannus formation between 1973 and 2004. We compared the initial 18-year period of surgery, when the Björk-Shiley tilting-disk valve was used, and the subsequent 13-year period of surgery, when the St. Jude Medical valve was used. Seven of a total of 390 patients (1.8%) required reoperation for prosthetic aortic valve obstruction due to pannus formation. All seven patients were women; four patients underwent resection of the pannus and three patients needed replacement of the valve. The frequency of pannus formation in the early group was 2.4% (6/253), whereas it was 0.73% (1/137) in the late group (P < 0.05). Pannus was localized at the minor orifice of the Björk-Shiley valve in the early group and turbulent transvalvular blood flow was considered to be one of the important factors triggering its growth. We also consider that small bileaflet valves have the possibility of promoting pannus formation and that the implantation of a larger prosthesis can contribute to reducing the occurrence of pannus.
TandemHeart as a Bridge to Recovery in Legionella Myocarditis.
Briceño, David F; Fernando, Rajeev R; Nathan, Sriram; Loyalka, Pranav; Kar, Biswajit; Gregoric, Igor D
2015-08-01
Legionnaires' disease is the designation for pneumonia caused by the Legionella species. Among the rare extrapulmonary manifestations, cardiac involvement is most prevalent, in the forms of myocarditis, pericarditis, postcardiotomy syndrome, and prosthetic valve endocarditis. Mechanical circulatory support has proved to be a safe and effective bridge to myocardial recovery in patients with acute fulminant myocarditis; however, to our knowledge, this support has not been used in infectious myocarditis specifically related to Legionellosis. We describe a case of Legionella myocarditis associated with acute left ventricular dysfunction and repolarization abnormalities in a 48-year-old man. The patient fully recovered after left ventricular unloading with use of a TandemHeart percutaneous ventricular assist device. In addition, we review the English-language medical literature on Legionella myocarditis and focus on cardiac outcomes.
Open heart surgery after renal transplantation.
Yamamura, Mitsuhiro; Miyamoto, Yuji; Mitsuno, Masataka; Tanaka, Hiroe; Ryomoto, Masaaki; Fukui, Shinya; Tsujiya, Noriko; Kajiyama, Tetsuya; Nojima, Michio
2014-09-01
to evaluate the strategy for open heart surgery after renal transplantation performed in a single institution in Japan. we reviewed 6 open heart surgeries after renal transplantation in 5 patients, performed between January 1992 and December 2012. The patients were 3 men and 2 women with a mean age of 60 ± 11 years (range 46-68 years). They had old myocardial infarction and unstable angina, aortic and mitral stenosis, left arterial myxoma, aortic stenosis, and native valve endocarditis followed by prosthetic valve endocarditis. Operative procedures included coronary artery bypass grafting, double-valve replacement, resection of left arterial myxoma, 2 aortic valve replacements, and a double-valve replacement. Renal protection consisted of steroid cover (hydrocortisone 100-500 mg or methylprednisolone 1000 mg) and intravenous immunosuppressant infusion (cyclosporine 30-40 mg day(-1) or tacrolimus 1.0 mg day(-1)). 5 cases were uneventful and good renal graft function was maintained at discharge (serum creatinine 2.1 ± 0.5 mg dL(-1)). There was one operative death after emergency double-valve replacement for methicillin-resistant Staphylococcus aureus-associated prosthetic valve endocarditis. Although the endocarditis improved after valve replacement, the patient died of postoperative pneumonia on postoperative day 45. careful perioperative management can allow successful open heart surgery after renal transplantation. However, severe complications, especially methicillin-resistant Staphylococcus aureus infection, may cause renal graft loss. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
3D Bioprinting of Heterogeneous Aortic Valve Conduits with Alginate/Gelatin Hydrogels
Duan, Bin; Hockaday, Laura A.; Kang, Kevin H.; Butcher, Jonathan T.
2013-01-01
Heart valve disease is a serious and growing public health problem for which prosthetic replacement is most commonly indicated. Current prosthetic devices are inadequate for younger adults and growing children. Tissue engineered living aortic valve conduits have potential for remodeling, regeneration, and growth, but fabricating natural anatomical complexity with cellular heterogeneity remain challenging. In the current study, we implement 3D bioprinting to fabricate living alginate/gelatin hydrogel valve conduits with anatomical architecture and direct incorporation of dual cell types in a regionally constrained manner. Encapsulated aortic root sinus smooth muscle cells (SMC) and aortic valve leaflet interstitial cells (VIC) were viable within alginate/gelatin hydrogel discs over 7 days in culture. Acellular 3D printed hydrogels exhibited reduced modulus, ultimate strength, and peak strain reducing slightly over 7-day culture, while the tensile biomechanics of cell-laden hydrogels were maintained. Aortic valve conduits were successfully bioprinted with direct encapsulation of SMC in the valve root and VIC in the leaflets. Both cell types were viable (81.4±3.4% for SMC and 83.2±4.0% for VIC) within 3D printed tissues. Encapsulated SMC expressed elevated alpha-smooth muscle actin when printed in stiff matrix, while VIC expressed elevated vimentin in soft matrix. These results demonstrate that anatomically complex, heterogeneously encapsulated aortic valve hydrogel conduits can be fabricated with 3D bioprinting. PMID:23015540
Fatal Bioprosthetic Aortic Valve Endocarditis Due to Cardiobacterium valvarum▿
Geißdörfer, Walter; Tandler, René; Schlundt, Christian; Weyand, Michael; Daniel, Werner G.; Schoerner, Christoph
2007-01-01
Cardiobacterium valvarum was isolated from the blood of a 71-year-old man with fatal aortic valve endocarditis. The API NH system was used for phenotypic characterization of the C. valvarum strain. This is the first case of infective endocarditis caused by C. valvarum in Germany and the first case worldwide affecting a prosthetic valve and lacking an obvious dental focus. PMID:17475754
Severe right ventricular and tricuspid valve dysfunction after pericardiocentesis.
Kuroda, Maiko; Amano, Masashi; Enomoto, Soichiro; Miyake, Makoto; Kondo, Hirokazu; Tamura, Toshihiro; Kaitani, Kazuaki; Izumi, Chisato; Nakagawa, Yoshihisa
2016-10-01
Pericardiocentesis is performed to treat cardiac tamponade or diagnose the cause of pericardial effusion. Cardiogenic shock with right ventricular (RV) dysfunction is a rare complication after pericardiocentesis. We report a case of an 82-year-old man who suddenly suffered cardiopulmonary arrest 12 h after pericardiocentesis. A transthoracic echocardiogram showed remarkable RV dysfunction and tricuspid valve dysfunction. Tricuspid valve closure was severely impaired, and the tricuspid regurgitation signal showed laminar flow with an early peak. However, after treatment with high-dose inotropic drugs, hemodynamic parameters gradually recovered. A transthoracic echocardiogram performed 24 h later showed improved motion of the RV and the tricuspid valve, resulting in a reduction in tricuspid regurgitation. RV and tricuspid valve dysfunction after pericardiocentesis needs to be recognized as a critical complication. Physicians also need to pay attention to not only the amount of drainage but also underlying RV dysfunction.
Strut fracture of Björk-Shiley convexo-concave valve in Japan--risk of small valve size--.
Watarida, S; Shiraishi, S; Nishi, T; Imura, M; Yamamoto, Y; Hirokawa, R; Fujita, M
2001-08-01
The Björk-Shiley convexo-concave (BSCC) prosthetic valve was introduced in 1979. Between 1979 and 1986, approximately 86,000 BSCC valves were implanted. By December 31, 1994, 564 complete strut fractures had been reported to the manufacture. We experienced a case of an outlet strut fracture and investigated the risk of BSCC prosthetic valve fractures in Japan. To investigate the risk factor of a strut fracture in Japan, we investigated published cases of strut fractures. Between 1979 and 1986, 2021 BSCC valves were implanted in Japan. By January 31, 2000, 11 complete strut fractures of 60-degree BSCC valves including our case had occurred. The patients were eight males and three females. The average age at valve replacement was 42.4+/-8.1 years, and nine of eleven (81.8%) were patients < 50 years-old. The average age of the patients when the BSCC valve fractured was 47.7+/-6.4 years, and eight of eleven (72.7%) were patients <= 50 years old. All patients were implanted in the mitral position. The sizes of the BSCC valve were 27 mm (n=5) (45.5%), 29 mm (n=3) (27.2%), and 31 mm (n=3) (27.2%). Four patients died and seven patients survived. Although only 11 BSCC valve struts fractured and statistical analysis could not be performed, our findings suggest that the high risk group for a strut fracture in Japan is young male patients with a mitral valve, >= 27 mm in size with BSCC models manufactured before March 1982. When following-up patients with BSCC models manufactured before March 1982, the possibility of a strut fracture in all BSCC valve sizes should be kept in mind.
Yuan, Shi-Min
2016-01-01
Fungal endocarditis is a rare and fatal condition. The Candida and Aspergillus species are the two most common etiologic fungi found responsible for fungal endocarditis. Fever and changing heart murmur are the most common clinical manifestations. Some patients may have a fever of unknown origin as the onset symptom. The diagnosis of fungal endocarditis is challenging, and diagnosis of prosthetic valve fungal endocarditis is extremely difficult. The optimum antifungal therapy still remains debatable. Treating Candida endocarditis can be difficult because the Candida species can form biofilms on native and prosthetic heart valves. Combined treatment appears superior to monotherapy. Combination of antifungal therapy and surgical debridement might bring about better prognosis. PMID:27737409
Yuan, Shi-Min
2016-01-01
Fungal endocarditis is a rare and fatal condition. The Candida and Aspergillus species are the two most common etiologic fungi found responsible for fungal endocarditis. Fever and changing heart murmur are the most common clinical manifestations. Some patients may have a fever of unknown origin as the onset symptom. The diagnosis of fungal endocarditis is challenging, and diagnosis of prosthetic valve fungal endocarditis is extremely difficult. The optimum antifungal therapy still remains debatable. Treating Candida endocarditis can be difficult because the Candida species can form biofilms on native and prosthetic heart valves. Combined treatment appears superior to monotherapy. Combination of antifungal therapy and surgical debridement might bring about better prognosis.
Blotière, Pierre-Olivier; Hoen, Bruno; Lesclous, Philippe; Millot, Sarah; Rudant, Jérémie; Weill, Alain; Coste, Joel; Alla, François; Duval, Xavier
2017-01-01
Objective To assess the relation between invasive dental procedures and infective endocarditis associated with oral streptococci among people with prosthetic heart valves. Design Nationwide population based cohort and a case crossover study. Setting French national health insurance administrative data linked with the national hospital discharge database. Participants All adults aged more than 18 years, living in France, with medical procedure codes for positioning or replacement of prosthetic heart valves between July 2008 and July 2014. Main outcome measures Oral streptococcal infective endocarditis was identified using primary discharge diagnosis codes. In the cohort study, Poisson regression models were performed to estimate the rate of oral streptococcal infective endocarditis during the three month period after invasive dental procedures compared with non-exposure periods. In the case crossover study, conditional logistic regression models calculated the odds ratio and 95% confidence intervals comparing exposure to invasive dental procedures during the three month period preceding oral streptococcal infective endocarditis (case period) with three earlier control periods. Results The cohort included 138 876 adults with prosthetic heart valves (285 034 person years); 69 303 (49.9%) underwent at least one dental procedure. Among the 396 615 dental procedures performed, 103 463 (26.0%) were invasive and therefore presented an indication for antibiotic prophylaxis, which was performed in 52 280 (50.1%). With a median follow-up of 1.7 years, 267 people developed infective endocarditis associated with oral streptococci (incidence rate 93.7 per 100 000 person years, 95% confidence interval 82.4 to 104.9). Compared with non-exposure periods, no statistically significant increased rate of oral streptococcal infective endocarditis was observed during the three months after an invasive dental procedure (relative rate 1.25, 95% confidence interval 0.82 to 1.82; P=0.26) and after an invasive dental procedure without antibiotic prophylaxis (1.57, 0.90 to 2.53; P=0.08). In the case crossover analysis, exposure to invasive dental procedures was more frequent during case periods than during matched control periods (5.1% v 3.2%; odds ratio 1.66, 95% confidence interval 1.05 to 2.63; P=0.03). Conclusion Invasive dental procedures may contribute to the development of infective endocarditis in adults with prosthetic heart valves. PMID:28882817
Corynebacterium endocarditis species-specific risk factors and outcomes
Belmares, Jaime; Detterline, Stephanie; Pak, Janet B; Parada, Jorge P
2007-01-01
Background Corynebacterium species are recognized as uncommon agents of endocarditis, but little is known regarding species-specific risk factors and outcomes in Corynebacterium endocarditis. Methods Case report and Medline search of English language journals for cases of Corynebacterium endocarditis. Inclusion criteria required that cases be identified as endocarditis, having persistent Corynebacterium bacteremia, murmurs described by the authors as identifying the affected valve, or vegetations found by echocardiography or in surgical or autopsy specimens. Cases also required patient-specific information on risk factors and outcomes (age, gender, prior prosthetic valve, other prior nosocomial risk factors (infected valve, involvement of native versus prosthetic valve, need for valve replacement, and death) to be included in the analysis. Publications of Corynebacterium endocarditis which reported aggregate data were excluded. Univariate analysis was conducted with chi-square and t-tests, as appropriate, with p = 0.05 considered significant. Results 129 cases of Corynebacterium endocarditis involving nine species met inclusion criteria. Corynebacterium endocarditis typically infects the left heart of adult males and nearly one third of patients have underlying valvular disease. One quarter of patients required valve replacement and one half of patients died. Toxigenic C. diphtheriae is associated with pediatric infections (p < 0.001). Only C. amycolatum has a predilection for women (p = 0.024), while C. pseudodiphtheriticum infections are most frequent in men (p = 0.023). C. striatum, C. jeikeium and C. hemolyticum are associated with nosocomial risk factors (p < 0.001, 0.028, and 0.024, respectively). No species was found to have a predilection for any particular heart valve. C. pseudodiphtheriticum is associated with a previous prosthetic valve replacement (p = 0.004). C. jeikeium infections are more likely to require valve replacement (p = 0.026). Infections involving toxigenic C. diphtheriae and C. pseudodiphtheriticum are associated with decreased survival (p = 0.001 and 0.032, respectively). Conclusion We report the first analysis of species-specific risk factors and outcomes in Corynebacterium endocarditis. In addition to species-specific associations with age, gender, prior valvular diseases, and other nosocomial risk factors, we found differences in rates of need for valve replacement and death. This review highlights the seriousness of these infections, as up to 28% of patients required valve replacement and 43.5% died. PMID:17284316
Blot, W J; Omar, R Z; Kallewaard, M; Morton, L S; Fryzek, J P; Ibrahim, M A; Acheson, D; Taylor, K M; van der Graaf, Y
2001-03-01
Approximately 82,000 Björk-Shiley convexo-concave (BSCC) 60 degree prosthetic heart valves were implanted in patients worldwide between 1979 and 1986. Outlet strut fractures (OSF) of some of the valves were first reported shortly after their introduction. Here, the determinants of OSF are examined, and the between-country variation and long-term risk are assessed. Cohorts of patients in the UK, Netherlands and USA with 15,770 BSCC 60 degree heart valves were followed up to 18 years for the occurrence of OSF. Crude rates of OSF were highest in the UK (0.18% per year), intermediate in the Netherlands (0.13%), and lowest in the USA (0.06%), although risk factor adjustment reduced the inter-country differences. Furthermore, in the UK and Netherlands, OSF rates (particularly for mitral valves) declined with time since implantation, and between-country differences were considerably diminished 10 or more years post implantation. The risk of OSF decreased steadily with advancing patient age. Fracture rates were lower among women than men, and also varied significantly with valve size and position and OSF status of other valves in the same shoporder. This long-term follow up of BSCC 60 degree heart valve patients indicates that risk factors for valve fracture are generally similar in the UK, Netherlands and USA. It also identifies a strong association between fracture risk and age, newly reveals gender-related differences, and shows that the risk of valve fracture persisted, albeit at a reduced rate, into the 1990s.
CardiaMed mechanical valve: mid-term results of a multicenter clinical trial.
Nazarov, Vladimir M; Zheleznev, Sergey I; Bogachev-Prokophiev, Alexandr V; Afanasyev, Alexandr V; Nemchenko, Eugene V; Jeltovskiy, Yuri V; Lavinyukov, Sergey O
2014-01-01
Prosthesis choice is a major concern in valvular surgery. A multicenter clinical trial was performed to assess the efficacy and safety of the CardiaMed prosthetic heart valve. The study enrolled 420 patients who underwent mitral (209) or aortic (211) valve replacement from 2003 to 2004 at 7 institutions in Russia, and who were followed up from 2006 to 2011. The mean age was 52.2 ± 10.2 years (range, 12-78 years), 47.4% were female, and 99.05% completed the study. The maximum observation term was 7.5 years (2188.5 patient-years); 1081.6 patient-years for aortic and 1106.9 patient-years for mitral valve replacement. The overall 7-year survival rate was 85.1% ± 3.7%; 86.1% ± 4.8% and 84.4% ± 5.4% for aortic and mitral valve replacement, respectively. The 7-year freedom from valve-related death was 93.9% ± 3.7% and 94.5% ± 3.2% for aortic and mitral valve replacement, respectively. When early mortality (<30 days) was excluded, these rates were 94.8% ± 3.1% and 93.8% ± 3.82%, respectively. Linearized valve-dependent complication rates were determined for structural valve failure (0%/patient-year overall), thrombosis (0.63%/patient-year, all for mitral valve replacement), thromboembolic complications including transient neurologic deficits (0.13%/patient-year overall, 0.5%/patient-year for aortic valve replacement, 0.8%/patient-year for mitral valve replacement), hemorrhagic bleeding (0.64%/patient-year overall, 0.55%/patient-year for aortic valve replacement, 0.09%/patient-year for mitral valve replacement), prosthetic endocarditis (0.28%/patient-year overall, 0.28%/patient-year for aortic valve replacement, 0%/patient-year for mitral valve replacement), and hemolysis (0%/patient-year overall). The CardiaMed mechanical heart valve prostheses meets world standards of safety and efficacy.
Live 3D TEE demonstrates and guides the management of prosthetic mitral valve obstruction.
Chahal, Mangeet; Pandya, Utpal; Adlakha, Satjit; Khouri, Samer J
2011-08-01
A 43-year-old woman, with a remote history of rheumatic mitral stenosis and a St. Jude prosthetic mitral valve replacement, presented with shortness of breath and palpitations, shortly after a long flight. On admission, atrial fibrillation with a rapid ventricular response was noted in the setting of a long history of noncompliance with her anticoagulation. Transesophageal echocardiography (TEE) demonstrated multiple laminated thrombi in the left atrial appendage. Live three-dimensional (3D) TEE confirmed this diagnosis and demonstrated an immobile posterior leaflet of the mitral prosthesis, which had direct implications in her management. She successfully underwent surgery for mitral valve replacement, left atrial appendage ligation, and a Maze procedure on the following day. The multiple thrombi within the atrial appendage were confirmed intraoperatively and pannus formation was determined to be the etiology of the leaflet immobility. © 2011, Wiley Periodicals, Inc.
Surgical Treatment in Active Infective Endocarditis: Results of a Four-Year Experience
Rostagno, Carlo; Carone, Enrico; Rossi, Alessandra; Gensini, Gian Franco; Stefano, Pier Luigi
2011-01-01
Background. Aim of present investigation was to analyze survival and recurrence rate in patients with active endocarditis referred to our centre for surgical treatment. Methods. 80 consecutive patients with active infective endocarditis (52 males, 28 females, mean age 59.2 years) were referred to our institution for surgical treatment. 78 patients underwent surgery, and 2 patients died before intervention. Results. Fifty patients had native valve endocarditis, 30 prosthetic valve involvement. Hospital mortality has been 10.2%. Three discharged patients (4.9%) died at an average 18-month followup. Endocarditis recurred in 4 (2 being S. aureus prosthetic tricuspid endocarditis in drug addicts). All patients who underwent valve repair or homograft implant were alive and free of recurrence. Conclusions. Our results suggest that with proper surgical treatment patients with active endocarditis discharged alive from hospital have a survival >90% at 18 months with a low recurrence rate. PMID:22347645
Virk, Hafeez Ul Hassan; Inayat, Faisal; Farooq, Salman; Ghani, Ali Raza; Mirrani, Ghazi A; Athar, Muhammed Waqas
2016-06-01
Coronary embolization is potentially a fatal sequela of endocarditis. Although the primary cause of acute coronary syndrome is atherosclerotic disease, it is imperative to consider septic embolism as an etiological factor. Herein, we report a case of ventricular fibrillation and ST-segment depression myocardial infarction occurring in a patient who initially presented with fever and increased urinary frequency. Coronary angiography revealed new 99% occlusion of the left main coronary artery (LMCA). Transesophageal echocardiography showed bioprosthetic aortic valve with an abscess and vegetation. Histologic examination of the embolectomy specimen confirmed the presence of thrombus and Enterococcus faecalis bacteria. Subsequently, the patient was discharged to the skilled nursing facility in a stable condition where he completed 6 weeks of intravenous ampicillin. We present a rare case of LMCA embolism due to prosthetic valve endocarditis. The present report also highlights the diagnostic and therapeutic challenges associated with such patients.
Transapical Transcatheter Aortic Valve Implantation Using the JenaValve: A One-Year Follow-up.
Reuthebuch, Oliver; Koechlin, Luca; Kaufmann, Beat A; Kessel-Schaefer, Arnheid; Gahl, Brigitta; Eckstein, Friedrich S
2015-09-01
Since the first transcatheter aortic valve implantation (TAVI) in 2002, TAVI technique has gained an increasing popularity especially in high-risk patients. In this study, we present the first echocardiographic midterm outcome with the second-generation transapical JenaValve TAVI system (JenaValve Technology GmbH, Munich, Germany) in patients with aortic stenosis (AS). Between November 2011 and November 2012, a total of 28 patients received transapical TAVI using the JenaValve. Primary endpoint was a combined efficacy endpoint after 1 year, which included all-cause mortality after more than 30 days, failure of current therapy for AS requiring hospitalization for symptoms of valve-related cardiac decompensation or prosthetic heart valve dysfunction. Moreover, we analyzed secondary endpoints after 3 and 12 months including cardiovascular mortality; major stroke; and life-threatening, disabling, or major bleeding. Mean echocardiographic follow-up was 471.35 ± 102.72 days. Mean age was 80.43 ± 6.03 years and EuroSCORE II was 8.80 ± 7.21%. Successful implantation was accomplished in 100% (n = 28). Median transvalvular aortic mean pressure gradient was 44.5 mm Hg (interquartile range [IQR]: 34.5; 55.5) preoperatively, 12 mm Hg (IQR: 9; 16) postoperatively, and 11 mm Hg (IQR: 8; 16) after 1 year. After 12 months, no paravalvular leakage was seen in 52.38% of the patients and grade 1 paravalvular leakage was seen in 47.62% of the patients. There was no grade 2 or 3 leakage detected. Stroke, valve thrombosis or dislocation, myocardial infarction, or bleeding was also not observed. However, criteria for the combined efficacy endpoint after 1 year were met in five patients (17.86%). Thirty-day mortality was 14.29% (n = 4) and all-cause mortality after 1 year was 21.43% (n = 6). The JenaValve transapical TAVI system is a safe and feasible procedure with low peri- and postoperative complications and convincing midterm performance of the prosthesis. Georg Thieme Verlag KG Stuttgart · New York.
In Vitro Evaluation of a Novel Hemodynamically Optimized Trileaflet Polymeric Prosthetic Heart Valve
Claiborne, Thomas E.; Sheriff, Jawaad; Kuetting, Maximilian; Steinseifer, Ulrich; Slepian, Marvin J.; Bluestein, Danny
2013-01-01
Calcific aortic valve disease is the most common and life threatening form of valvular heart disease, characterized by stenosis and regurgitation, which is currently treated at the symptomatic end-stages via open-heart surgical replacement of the diseased valve with, typically, either a xenograft tissue valve or a pyrolytic carbon mechanical heart valve. These options offer the clinician a choice between structural valve deterioration and chronic anticoagulant therapy, respectively, effectively replacing one disease with another. Polymeric prosthetic heart valves (PHV) offer the promise of reducing or eliminating these complications, and they may be better suited for the new transcatheter aortic valve replacement (TAVR) procedure, which currently utilizes tissue valves. New evidence indicates that the latter may incur damage during implantation. Polymer PHVs may also be incorporated into pulsatile circulatory support devices such as total artificial heart and ventricular assist devices that currently employ mechanical PHVs. Development of polymer PHVs, however, has been slow due to the lack of sufficiently durable and biocompatible polymers. We have designed a new trileaflet polymer PHV for surgical implantation employing a novel polymer—xSIBS—that offers superior bio-stability and durability. The design of this polymer PHV was optimized for reduced stresses, improved hemodynamic performance, and reduced thrombogenicity using our device thrombogenicity emulation (DTE) methodology, the results of which have been published separately. Here we present our new design, prototype fabrication methods, hydrodynamics performance testing, and platelet activation measurements performed in the optimized valve prototype and compare it to the performance of a gold standard tissue valve. The hydrodynamic performance of the two valves was comparable in all measures, with a certain advantage to our valve during regurgitation. There was no significant difference between the platelet activation rates of our polymer valve and the tissue valve, indicating that similar to the latter, its recipients may not require anticoagulation. This work proves the feasibility of our optimized polymer PHV design and brings polymeric valves closer to clinical viability. PMID:23445066
Shinn, Sung Ho; Dayan, Victor; Schaff, Hartzell V; Dearani, Joseph A; Joyce, Lyle D; Lahr, Brian; Greason, Kevin L; Stulak, John M; Daly, Richard C
2016-08-01
There is controversy regarding the comparative effectiveness of methods of tricuspid valve (TV) repair-prosthetic ring versus suture annuloplasty-in patients undergoing operation for primary mitral valve (MV) disease. In this study, we analyzed factors associated with patient survival and recurrent tricuspid regurgitation (TR) following TV repair and focused on results stratified by method of tricuspid valve repair. We reviewed patients who underwent TV repair with suture (De Vega) or flexible ring annuloplasties at the time of MV surgery from 1995 to 2010. Patients with prior cardiac or concomitant aortic valve operations were excluded. Propensity matching was performed to account for potential differences in baseline characteristics between the groups. Primary outcomes were long-term mortality and postoperative TR grade. In the overall study, there were 415 patients with median age 72 years (range, 63-78 years), from which 148 matched pairs were identified by propensity score analysis. In the overall cohort, patients in the ring annuloplasty group more often had preoperative transvenous pacemakers (P = .05), lower ejection fractions (P = .028), and more recent years of operation (P < .001). For patients who had De Vega suture annuloplasty, long-term mortality was not different from that of patients who had ring annuloplasty (hazard ratio, 0.93; 95% confidence interval, 0.67-1.30). Older age, preoperative diabetes, and preoperative right ventricular dysfunction were predictors for long-term mortality. Durability of the annuloplasty methods was similar with no significant difference in trend of recurrent TR grades over follow-up (P = .807). Etiology of mitral regurgitation was not associated with recurrent TR during follow-up (P = .857). Late survival and TV durability following concomitant TV repair during MV surgery did not differ with respect to TV repair technique. In this series of patients with repaired tricuspid valves, etiology of MV disease did not influence postoperative changes in TR. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Habets, J; Meijer, T S; Meijer, R C A; Mali, W P Th M; Vonken, E-J P A; Budde, R P J
2012-01-01
Objectives Sutures with polytetrafluorethylene (PTFE) felt pledgets are commonly used in prosthetic heart valve (PHV) implantation. Paravalvular leakage can be difficult to distinguish from PTFE felt pledgets on multislice CT because both present as hyperdense structures. We assessed whether pledgets can be discriminated from contrast-enhanced solutions (blood/saline) on CT images based on attenuation difference in an ex vivo experiment and under in vivo conditions. Methods PTFE felt pledgets were sutured to the suture ring of a mechanical PHV and porcine aortic annulus, and immersed and scanned in four different contrast-enhanced (Ultravist®; 300 mg jopromide ml−1) saline concentrations (10.0, 12.0, 13.6 and 15.0 mg ml−1). Scanning was performed on a 256-slice scanner with eight different scan protocols with various tube voltage (100 kV, 120 kV) and tube current (400 mAs, 600 mAs, 800 mAs, 1000 mAs) settings. Attenuation of the pledgets and surrounding contrast-enhanced saline were measured. Additionally, the attenuation of pledgets and contrast-enhanced blood was measured on electrocardiography (ECG)-gated CTA scans of 19 patients with 22 PHVs. Results Ex vivo CT attenuation differences between the pledgets and contrast-enhanced solutions were larger by using higher tube voltages. CT attenuation values of the pledgets were higher than contrast-enhanced blood in patients: 420±26 Hounsfield units (mean±SD, range 383–494) and 288±41 Hounsfield units (range 202–367), respectively. Conclusions PTFE felt pledgets have consistently higher attenuation than surrounding contrast-enhanced blood. CT attenuation measurements therefore may help to differentiate pledgets from paravalvular leakage, and detect paravalvular leakage in patients with suspected PHV dysfunction. PMID:22919014
Design Studies of Cardiac Valve Prostheses
Liotta, Domingo
1985-01-01
This paper indicates the vital importance of considering prosthesis articulation in the design of cardiac valves. The prosthesis articulation interrelates with the fixed and the movable prosthetic components. Two basic physiological hemodynamic principles are reviewed: [List: see text] A bileaflet, free-tilting, swivelling prosthesis with a central articular mechanism is undergoing investigation. The four articulations have their own perennial preserving mechanisms to prevent potential failure mode by collecting blood elements in the valve tilting design. PMID:15227041
Mechanical performance of pyrolytic carbon in prosthetic heart valve applications.
Cao, H
1996-06-01
An experimental procedure has been developed for rigorous characterization of the fracture resistance and fatigue crack extension in pyrolytic carbon for prosthetic heart valve application. Experiments were conducted under sustained and cyclic loading in a simulated biological environment using Carbomedics Pyrolite carbon. While the material was shown to have modest fracture toughness, it exhibited excellent resistance to subcritical crack growth. The crack growth kinetics in pyrolytic carbon were formulated using a phenomenological description. A fatigue threshold was observed below which the crack growth rate diminishes. A damage tolerance concept based on fracture mechanics was used to develop an engineering design approach for mechanical heart valve prostheses. In particular, a new quantity, referred to as the safe-life index, was introduced to assess the design adequacy against subcritical crack growth in brittle materials. In addition, a weakest-link statistical description of the fracture strength is provided and used in the design of component proof-tests. It is shown that the structural reliability of mechanical heart valves can be assured by combining effective flaw detection and manufacturing quality control with adequate damage tolerance design.
Total prosthetic replacement of atrioventricular valves in the dog
Den Otter, G.
1968-01-01
The free-floating cone and cage valve, described in a previous study as being successful as a substitute for the right atrioventricular valve, does not perform well when it is inserted in the mitral ostium. A tilting cone or disc was constructed and tested in a series of 15 dogs. This prosthesis gave excellent results in 12 animals. The reasons for its failure in the remaining three is discussed. The prosthesis presented has advantages over any ball and cage valve, mainly because of its smaller volume. Images PMID:5654076
Computed Flow Through An Artificial Heart Valve
NASA Technical Reports Server (NTRS)
Rogers, Stewart E.; Kwak, Dochan; Kiris, Cetin; Chang, I-Dee
1994-01-01
Report discusses computations of blood flow through prosthetic tilting disk valve. Computational procedure developed in simulation used to design better artificial hearts and valves by reducing or eliminating following adverse flow characteristics: large pressure losses, which prevent hearts from working efficiently; separated and secondary flows, which causes clotting; and high turbulent shear stresses, which damages red blood cells. Report reiterates and expands upon part of NASA technical memorandum "Computed Flow Through an Artificial Heart and Valve" (ARC-12983). Also based partly on research described in "Numerical Simulation of Flow Through an Artificial Heart" (ARC-12478).
HACEK Infective Endocarditis: Characteristics and Outcomes from a Large, Multi-National Cohort
Chambers, Stephen T.; Murdoch, David; Morris, Arthur; Holland, David; Pappas, Paul; Almela, Manel; Fernández-Hidalgo, Nuria; Almirante, Benito; Bouza, Emilio; Forno, Davide; del Rio, Ana; Hannan, Margaret M.; Harkness, John; Kanafani, Zeina A.; Lalani, Tahaniyat; Lang, Selwyn; Raymond, Nigel; Read, Kerry; Vinogradova, Tatiana; Woods, Christopher W.; Wray, Dannah; Corey, G. Ralph; Chu, Vivian H.
2013-01-01
The HACEK organisms (Haemophilus species, Aggregatibacter species, Cardiobacterium hominis, Eikenella corrodens, and Kingella species) are rare causes of infective endocarditis (IE). The objective of this study is to describe the clinical characteristics and outcomes of patients with HACEK endocarditis (HE) in a large multi-national cohort. Patients hospitalized with definite or possible infective endocarditis by the International Collaboration on Endocarditis Prospective Cohort Study in 64 hospitals from 28 countries were included and characteristics of HE patients compared with IE due to other pathogens. Of 5591 patients enrolled, 77 (1.4%) had HE. HE was associated with a younger age (47 vs. 61 years; p<0.001), a higher prevalence of immunologic/vascular manifestations (32% vs. 20%; p<0.008) and stroke (25% vs. 17% p = 0.05) but a lower prevalence of congestive heart failure (15% vs. 30%; p = 0.004), death in-hospital (4% vs. 18%; p = 0.001) or after 1 year follow-up (6% vs. 20%; p = 0.01) than IE due to other pathogens (n = 5514). On multivariable analysis, stroke was associated with mitral valve vegetations (OR 3.60; CI 1.34–9.65; p<0.01) and younger age (OR 0.62; CI 0.49–0.90; p<0.01). The overall outcome of HE was excellent with the in-hospital mortality (4%) significantly better than for non-HE (18%; p<0.001). Prosthetic valve endocarditis was more common in HE (35%) than non-HE (24%). The outcome of prosthetic valve and native valve HE was excellent whether treated medically or with surgery. Current treatment is very successful for the management of both native valve prosthetic valve HE but further studies are needed to determine why HE has a predilection for younger people and to cause stroke. The small number of patients and observational design limit inferences on treatment strategies. Self selection of study sites limits epidemiological inferences. PMID:23690995
HACEK infective endocarditis: characteristics and outcomes from a large, multi-national cohort.
Chambers, Stephen T; Murdoch, David; Morris, Arthur; Holland, David; Pappas, Paul; Almela, Manel; Fernández-Hidalgo, Nuria; Almirante, Benito; Bouza, Emilio; Forno, Davide; del Rio, Ana; Hannan, Margaret M; Harkness, John; Kanafani, Zeina A; Lalani, Tahaniyat; Lang, Selwyn; Raymond, Nigel; Read, Kerry; Vinogradova, Tatiana; Woods, Christopher W; Wray, Dannah; Corey, G Ralph; Chu, Vivian H
2013-01-01
The HACEK organisms (Haemophilus species, Aggregatibacter species, Cardiobacterium hominis, Eikenella corrodens, and Kingella species) are rare causes of infective endocarditis (IE). The objective of this study is to describe the clinical characteristics and outcomes of patients with HACEK endocarditis (HE) in a large multi-national cohort. Patients hospitalized with definite or possible infective endocarditis by the International Collaboration on Endocarditis Prospective Cohort Study in 64 hospitals from 28 countries were included and characteristics of HE patients compared with IE due to other pathogens. Of 5591 patients enrolled, 77 (1.4%) had HE. HE was associated with a younger age (47 vs. 61 years; p<0.001), a higher prevalence of immunologic/vascular manifestations (32% vs. 20%; p<0.008) and stroke (25% vs. 17% p = 0.05) but a lower prevalence of congestive heart failure (15% vs. 30%; p = 0.004), death in-hospital (4% vs. 18%; p = 0.001) or after 1 year follow-up (6% vs. 20%; p = 0.01) than IE due to other pathogens (n = 5514). On multivariable analysis, stroke was associated with mitral valve vegetations (OR 3.60; CI 1.34-9.65; p<0.01) and younger age (OR 0.62; CI 0.49-0.90; p<0.01). The overall outcome of HE was excellent with the in-hospital mortality (4%) significantly better than for non-HE (18%; p<0.001). Prosthetic valve endocarditis was more common in HE (35%) than non-HE (24%). The outcome of prosthetic valve and native valve HE was excellent whether treated medically or with surgery. Current treatment is very successful for the management of both native valve prosthetic valve HE but further studies are needed to determine why HE has a predilection for younger people and to cause stroke. The small number of patients and observational design limit inferences on treatment strategies. Self selection of study sites limits epidemiological inferences.
2011-01-01
Background Valve dysfunction is a common cardiovascular pathology. Despite significant clinical research, there is little formal study of how valve dysfunction affects overall circulatory dynamics. Validated models would offer the ability to better understand these dynamics and thus optimize diagnosis, as well as surgical and other interventions. Methods A cardiovascular and circulatory system (CVS) model has already been validated in silico, and in several animal model studies. It accounts for valve dynamics using Heaviside functions to simulate a physiologically accurate "open on pressure, close on flow" law. However, it does not consider real-time valve opening dynamics and therefore does not fully capture valve dysfunction, particularly where the dysfunction involves partial closure. This research describes an updated version of this previous closed-loop CVS model that includes the progressive opening of the mitral valve, and is defined over the full cardiac cycle. Results Simulations of the cardiovascular system with healthy mitral valve are performed, and, the global hemodynamic behaviour is studied compared with previously validated results. The error between resulting pressure-volume (PV) loops of already validated CVS model and the new CVS model that includes the progressive opening of the mitral valve is assessed and remains within typical measurement error and variability. Simulations of ischemic mitral insufficiency are also performed. Pressure-Volume loops, transmitral flow evolution and mitral valve aperture area evolution follow reported measurements in shape, amplitude and trends. Conclusions The resulting cardiovascular system model including mitral valve dynamics provides a foundation for clinical validation and the study of valvular dysfunction in vivo. The overall models and results could readily be generalised to other cardiac valves. PMID:21942971
[Late complications following Björk-Shiley and St. Jude Medical heart valve replacement].
Horstkotte, D; Körfer, R; Budde, T; Haerten, K; Schulte, H D; Bircks, W; Loogen, F
1983-05-01
Valve-related complications after Björk-Shiley mitral (n = 475), aortic (n = 424), or mitral-aortic implantation (n = 119) were compared to complications after St. Jude mitral (n = 173), aortic (n = 152), and St. Jude mitral and aortic (n = 63) replacements. The 1,018 consecutive patients with Björk-Shiley valves had been operated upon between 1974 and 1982, those with St. Jude valves between 1978 and 1982. All patients were placed on anticoagulant therapy with phenprocoumon early after operation and no significant intergroup differences in the effectiveness of the anticoagulant therapy were found. At a comparable follow-up time of approximately 23 months, 24 major thromboembolic episodes were observed after Björk-Shiley mitral (BSM) and 3 after St. Jude mitral valve implantation (SJM), corresponding to a thromboembolic rate of 2.82/100 patient years with BSM and 0.93/100 patient years with SJM. After aortic valve replacements, 1.93 events in 100 patient years occurred after Björk-Shiley aortic (BSA) and 0.73 after St. Jude aortic implantation (SJA). In patients with double valve replacements, these rates were 3.2 (BSM + BSA) and 0.88 (SJM + SJA), respectively. The cerebral vessels were involved in 52% and the arteries of the extremities in 22% of these major events. Six Björk-Shiley prostheses had to be replaced because of valve thrombosis. The overall incidence of severe hemorrhagic complications was 2.94/100 patient years in BSM and 1.79 in SJM. After aortic valve replacement, we found rates of 1.80/100 patient years (BSA) and 2.57/100 patient years (SJA), respectively. Intravascular hemolysis no longer seems to be a significant clinical problem. However, indications of red cell damage after heart valve replacement were significantly greater in patients with perivalvular leakage, valve thrombosis, or dysfunction than in those with normally functioning prostheses. Reoperations were necessary because of valve thrombosis (0.46%), perivalvular leakage (2.2%), or prosthetic valve endocarditis with concomitant perivalvular regurgitation (0.46%). One valve had to be replaced because of fracture of the outlet strut of a BSM prosthesis. Hemorrhage due to the anticoagulant treatment was thus the most frequent complication, without significant intergroup differences, while thromboembolic complications were significantly more frequent after Björk-Shiley mitral, aortic, and double valve replacements than after St. Jude implantation. This may lead to the consideration of a change in the prophylaxis of thrombus formations with the St. Jude valve, especially in aortic valve replacements with sinus rhythm.
Laser Doppler anemometry measurements of steady flow through two bi-leaflet prosthetic heart valves
Bazan, Ovandir; Ortiz, Jayme Pinto; Vieira Junior, Francisco Ubaldo; Vieira, Reinaldo Wilson; Antunes, Nilson; Tabacow, Fabio Bittencourt Dutra; Costa, Eduardo Tavares; Petrucci Junior, Orlando
2013-01-01
Introduction In vitro hydrodynamic characterization of prosthetic heart valves provides important information regarding their operation, especially if performed by noninvasive techniques of anemometry. Once velocity profiles for each valve are provided, it is possible to compare them in terms of hydrodynamic performance. In this first experimental study using laser doppler anemometry with mechanical valves, the simulations were performed at a steady flow workbench. Objective To compare unidimensional velocity profiles at the central plane of two bi-leaflet aortic prosthesis from St. Jude (AGN 21 - 751 and 21 AJ - 501 models) exposed to a steady flow regime, on four distinct sections, three downstream and one upstream. Methods To provide similar conditions for the flow through each prosthesis by a steady flow workbench (water, flow rate of 17L/min. ) and, for the same sections and sweeps, to obtain the velocity profiles of each heart valve by unidimensional measurements. Results It was found that higher velocities correspond to the prosthesis with smaller inner diameter and instabilities of flow are larger as the section of interest is closer to the valve. Regions of recirculation, stagnation of flow, low pressure, and flow peak velocities were also found. Conclusions Considering the hydrodynamic aspect and for every section measured, it could be concluded that the prosthesis model AGN 21 - 751 (RegentTM) is superior to the 21 AJ - 501 model (Master Series). Based on the results, future studies can choose to focus on specific regions of the these valves. PMID:24598950
Insidious strut fractures in a DeBakey-Surgitool aortic valve prosthesis.
Scott, S M; Sethi, G K; Paulson, D M; Takaro, T
1978-04-01
Recent reports of cage wear occurring in DeBakey-Surgitool aortic valve prostheses prompted us to examine with image intensification all our patients who have had this type of prosthesis implanted. One patient, who was asymptomatic, was discovered to have a prosthesis with two fractured struts. This patient's prosthetic valve was replaced successfully with a stented porcine heterograft prosthesis. Including the valve removed from this patient, 8 DeBakey-Surgitool aortic valves with structural defects have been reported to the manufacturer. In the absence of a catastrophic event, patients with valves having fractured or worn struts may be totally asymptomatic, and routine periodic roentgenographic examination may be the only way of detecting strut wear or fracture.
Propionibacterium acnes endocarditis: a case series.
Banzon, J M; Rehm, S J; Gordon, S M; Hussain, S T; Pettersson, G B; Shrestha, N K
2017-06-01
Propionibacterium acnes remains a rare cause of infective endocarditis (IE). It is challenging to diagnose due to the organism's fastidious nature and the indolent presentation of the disease. The purpose of this study was to describe the clinical presentation and management of P. acnes IE with an emphasis on the methods of diagnosis. We identified patients from the Cleveland Clinic Infective Endocarditis Registry who were admitted from 2007 to 2015 with definite IE by Duke Criteria. Propionibacterium acnes was defined as the causative pathogen if it was identified in at least two culture specimens, or identified with at least two different modalities: blood culture, valve culture, valve sequencing or histopathological demonstration of microorganisms. We identified 24 cases of P. acnes IE, 23 (96%) of which were either prosthetic valve endocarditis or IE on an annuloplasty ring. Invasive disease (71%) and embolic complications (29%) were common. All but one patient underwent surgery. Propionibacterium acnes was identified in 12.5% of routine blood cultures, 75% of blood cultures with extended incubation, 55% of valve cultures, and 95% of valve sequencing specimens. In 11 of 24 patients (46%), no causative pathogen would have been identified without valve sequencing. Propionibacterium acnes almost exclusively causes prosthetic valve endocarditis and patients often present with advanced disease. The organism may not be readily cultured, and extended cultures appear to be necessary. In patients who have undergone surgery, valve sequencing is most reliable in establishing the diagnosis. Copyright © 2017 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Toyota, Kosaku; Ota, Takashi; Nagamine, Katsutoshi; Koide, Yasuhiro; Nomura, Takeshi; Yamanaka, Futoshi; Shishido, Koki; Tanaka, Masashi; Saito, Shigeru
2016-12-01
Transcatheter aortic valve implantation (TAVI) for patients with aortic stenosis is a less invasive alternative to surgical aortic valve replacement. Despite this, careful anesthetic management, especially strict control of blood pressure and fluid management, is necessary. During TAVI, normalization of left ventricular afterload due to aortic balloon valvuloplasty and prosthetic valve deployment is expected to result in rapid improvement of systolic function and consequent improvement in diastolic function. However, the early effect of TAVI on left ventricular diastolic function is less clear. We hypothesized that TAVI induces a rapid decrease in left ventricular end-diastolic pressure (LVEDP) after valve deployment. This retrospective observational study included 71 patients who had undergone TAVI using the transfemoral approach with a balloon-expandable valve under general anesthesia. Intraoperative LVEDP was measured using an intracardiac catheter. The severity of residual aortic regurgitation (AR) was assessed using the Sellers criteria. The mean (SD) LVEDP was 17.8 (5.3) mmHg just before TAVI and increased significantly to 27.3 (8.2) mmHg immediately after prosthetic valve deployment (p < 0.0001). The change in LVEDP was 8.7 (8.6) mmHg in patients with low residual AR (Sellers ≤1) and 11.0 (7.1) mmHg in those with high residual AR (Sellers ≥2); however, this difference was not significant. No correlation was found between the LVEDP change and intraoperative fluid balance. In conclusion, LVEDP increased significantly in the early period after valve deployment during TAVI, regardless of residual AR severity. It was suggested that the tolerability of fluid load could be reduced at that time.
Santoro, Rosaria; Consolo, Filippo; Spiccia, Marco; Piola, Marco; Kassem, Samer; Prandi, Francesca; Vinci, Maria Cristina; Forti, Elisa; Polvani, Gianluca; Fiore, Gianfranco Beniamino; Soncini, Monica; Pesce, Maurizio
2016-02-01
Glutaraldehyde-fixed pericardium of animal origin is the elective material for the fabrication of bio-prosthetic valves for surgical replacement of insufficient/stenotic cardiac valves. However, the pericardial tissue employed to this aim undergoes severe calcification due to chronic inflammation resulting from a non-complete immunological compatibility of the animal-derived pericardial tissue resulting from failure to remove animal-derived xeno-antigens. In the mid/long-term, this leads to structural deterioration, mechanical failure, and prosthesis leaflets rupture, with consequent need for re-intervention. In the search for novel procedures to maximize biological compatibility of the pericardial tissue into immunocompetent background, we have recently devised a procedure to decellularize the human pericardium as an alternative to fixation with aldehydes. In the present contribution, we used this procedure to derive sheets of decellularized pig pericardium. The decellularized tissue was first tested for the presence of 1,3 α-galactose (αGal), one of the main xenoantigens involved in prosthetic valve rejection, as well as for mechanical tensile behavior and distensibility, and finally seeded with pig- and human-derived aortic valve interstitial cells. We demonstrate that the decellularization procedure removed the αGAL antigen, maintained the mechanical characteristics of the native pig pericardium, and ensured an efficient surface colonization of the tissue by animal- and human-derived aortic valve interstitial cells. This establishes, for the first time, the feasibility of fixative-free pericardial tissue seeding with valve competent cells for derivation of tissue engineered heart valve leaflets. © 2015 Wiley Periodicals, Inc.
Hsi, David H; Ryan, Gerald F; Taft, Janice; Arnone, Thomas J
2003-01-01
An 81-year-old woman was evaluated for prosthetic mitral valve function. She had received a Harken disk mitral valve 29 years earlier due to severe mitral valve disease. This particular valve prosthesis is known for premature disk edge wear and erosion. The patients 2-dimensional Doppler echocardiogram showed the distinctive appearance of a disk mitral valve prosthesis. Color Doppler in diastole showed a unique crown appearance, with initial flow acceleration around the disk followed by convergence to laminar flow in the left ventricle. Cineradiographic imaging revealed normal valve function and minimal disk erosion. We believe this to be the longest reported follow-up of a surviving patient with a rare Harken disk valve. We present images with unique echocardiographic and cineangiographic features.
A 29-Year-Old Harken Disk Mitral Valve
Hsi, David H.; Ryan, Gerald F.; Taft, Janice; Arnone, Thomas J.
2003-01-01
An 81-year-old woman was evaluated for prosthetic mitral valve function. She had received a Harken disk mitral valve 29 years earlier due to severe mitral valve disease. This particular valve prosthesis is known for premature disk edge wear and erosion. The patient's 2-dimensional Doppler echocardiogram showed the distinctive appearance of a disk mitral valve prosthesis. Color Doppler in diastole showed a unique crown appearance, with initial flow acceleration around the disk followed by convergence to laminar flow in the left ventricle. Cineradiographic imaging revealed normal valve function and minimal disk erosion. We believe this to be the longest reported follow-up of a surviving patient with a rare Harken disk valve. We present images with unique echocardiographic and cineangiographic features. (Tex Heart Inst J 2003;30:319–21) PMID:14677746
Tran, Hoang M; Truong, Vien T; Ngo, Tam M N; Bui, Quoc P V; Nguyen, Hoang C; Le, Trung T Q; Mazur, Wojciech; Chung, Eugene; Cafardi, John M; Pham, Khanh P N; Duong, Hoang H N; Nguyen, Thach; Nguyen, Vu T; Pham, Vinh N
2017-01-01
We aimed to evaluate the microbiological characteristics and risk factors for mortality of infective endocarditis in two tertiary hospitals in Ho Chi Minh City, south Vietnam. A retrospective study of 189 patients (120 men, 69 women; mean age 38 ± 18 years) with the diagnosis of probable or definite infective endocarditis (IE) according to the modified Duke Criteria admitted to The Heart Institute or Tam Duc Hospital between January 2005 and December 2014. IE was related to a native valve in 165 patients (87.3%), and prosthetic valve in 24 (12.7%). Of the 189 patients in our series, the culture positive rate was 70.4%. The most common isolated pathogens were Streptococci (75.2%), Staphylococci (9.8%) followed by gram negative organism (4.5%). The sensitivity rate of Streptococci to ampicillin, ceftriaxone or vancomycin was 100%. The rate of methicillin resistant Staphylococcus aureus was 40%. There was a decrease in penicillin sensitivity for Streptococci over three eras: 2005-2007 (100%), 2008-2010 (94%) and 2010-2014 (84%). The in-hospital mortality rate was 6.9%. Logistic regression analysis found prosthetic valve and NYHA grade 3 or 4 heart failure and vegetation size of more than 15 mm as strong predictors of in-hospital mortality. Streptococcal species were the major pathogen of IE in the recent years with low rates of antimicrobial resistance. Prosthetic valve involvement, moderate or severe heart failure and vegetation size of more than 15 mm were independent predictors for in-hospital mortality in IE.
Bade, Arun Shivajirao; Shaikh, Shakil Sattar Ahmed; Khemani, Hemant; Singh, Gurkirat; Bansal, Narender Omprakash
2018-01-01
Background Thrombosis is a complication of prosthetic valves on oral anticoagulants which is associated with significant morbidity and mortality. A re-operation carries a substantial risk, with mortality rate from 10% to 15% in selected series, which may be 2- or 3-folds higher in critically ill patients. This study conducted in a tertiary care cardiology unit aimed to evaluate the effectiveness and safety of thrombolytic therapy in stuck mitral bileaflet heart valves. Methods As a prospective observational study, clinical symptoms and fluoroscopy were the mainstay in diagnosis of stuck mitral valve. Gradient across the valve by transthoracic echocardiography was used to monitor the therapy every 6 h. Fall of mean gradient more than 50% was considered as successful thrombolysis. And final results were again checked by fluoroscopy with documentation of improved leaflet movement. Results Totally we studied 34 patients. Patients receiving thrombolytic therapy with streptokinase achieved an overall 91.2% freedom from a repeat operation or major complications, a large subcutaneous hematoma occurred in one ( 2.9%), reoperation required in two due to failure of treatment (5.9%), allergic reaction in one (2.9%), one patient developed transient neurologic dysfunction (2.9%) and one patient died during therapy due to refractory cardiogenic shock(2.9%). All patients including those with delayed presentation (> 14 days) and hemodynamically unstable patients had good results similar to those who presented within 14 days and hemodynamically stable. Mortality was higher in unstable patients and reoperation was higher with delayed presentation. Conclusions Thrombolysis with streptokinase is highly successful and safe therapy in hemodynamically stable as well as unstable patients, or those with early or delayed presentation with stuck bileaflet mitral valves, especially in centers where round the clock cardiothoracic surgery backup is not available. PMID:29904451
The Melody® valve and Ensemble® delivery system for transcatheter pulmonary valve replacement
McElhinney, Doff B; Hennesen, Jill T
2013-01-01
The Melody® transcatheter pulmonary valve (TPV) is a percutaneous valve system designed for the treatment of obstruction and/or regurgitation of prosthetic conduits placed between the right ventricle and pulmonary arteries in patients with congenital heart disease. In 2000, Melody TPV became the first transcatheter valve implanted in a human; in 2006 it became the first transcatheter valve commercially available anywhere in the world; and in 2010 it was launched as the first commercially available transcatheter valve in the United States. In this review, we present the clinical background against which the Melody valve was developed and implemented, introduce the rationale for and challenges of transcatheter valve technology for this population, outline the history and technical details of its development and use, and summarize currently available data concerning the performance of the device. PMID:23834411
[Short and long term results of aortic valve replacement in patients 80 years of age and older].
Mortasawi, A; Gehle, S; Yaghmaie, M; Schröder, T; Ennker, I C; Rosendahl, U; Albert, A; Ennker, J
2001-03-01
Due to demographic changes in average life expectancy the age of patients undergoing cardiac surgery is increasing as well. We have reviewed the short- and long-term outcome in patients over 80 years of age after aortic valve replacement with or without concomitant coronary grafting. From 1.1.1995 until 31.12.1999, 126 patients (93 women, 33 men between 80 and 89 years, 82.8 +/- 2.4) underwent aortic valve replacement. 64 patients (group A) received isolated valve replacement, 62 (group B) underwent myocardial revascularization as well. The 30-day hospital mortality rate was 6.3% for group A and 14.5% for group B. The follow-up time ranged between 3 and 63 months (32 +/- 16). None of the patients had to be reoperated for prosthetic valve dysfunction or endocarditis. Bleeding complications due to anticoagulation therapy were observed by one patient from group A 3 years after the operation. Of the 15 deaths during the follow-up period seven (47%) were cardiac in nature and two (13%) related to stroke. Acturial survival rates for group A were 89%, 85% and 77% at 1, 2 and 3 years, and for group B 76%, 72% and 70%. Permanent nursing care was not required 1 year after the operation by 100% of patients in group A (2 years: 98%, 3 years 95%) and by 100% of patients in group B (2 years: 93%, 3 years: 90%). At an interval of 1 year after the operation 96% of patients in group A had not been hospitalized as a result of cardiac disorders (2 years: 96%, 3 years: 94%). The rates for group B were 88%, 81% and 75%. Compared with younger age groups, aortic valve replacement in patients 80 years of age and older is associated with a distinctly increased mortality and morbidity. However, our data suggest that considering the poor prognosis of conservative therapy of symptomatic aortic valve disease, functional status as well as life expectancy in this age group seem to be positively influenced by aortic valve replacement.
Prosthetic aortic valve: a bone in the system.
Pereira, Vitor Hugo; Guardado, Joana; Fernandes, Marina; Lourenço, Mário; Machado, Inocência; Quelhas, Isabel; Azevedo, Olga; Lourenço, António
2015-02-01
We report a case of a 73-year-old female patient admitted to the surgical department for a splenic abscess. She had a history of a mechanical aortic valve implanted two years earlier. During the diagnostic work-up, the patient underwent a transesophageal echocardiogram that revealed the presence of multiple paravalvular abscesses, establishing the diagnosis of prosthetic valve endocarditis. A few days later, the echocardiogram was repeated due to a new-onset systolic-diastolic murmur. A large pseudoaneurysm and significant periprosthetic regurgitation were now noted and the patient was referred for cardiac surgery. The microbiologic exam revealed the presence of Streptococcus milleri, usually found in the gastrointestinal flora and a known pathogenic agent of endocarditis. Interestingly, the patient had had a foreign body (bone fragment) removed from her esophagus a few weeks earlier, which was the probable portal of entry for this infective endocarditis. Copyright © 2014 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.
Ergenoglu, Mehmet U; Yerebakan, Halit; Ozveren, Olcay; Koner, Ozge; Kalangos, Afksendiyos; Demirsoy, Ergun
2011-10-01
Congenitally corrected transposition of the great arteries, which is characterized by atrioventricular and ventriculoarterial discordance, is a rare congenital heart disease. Most of the cases are diagnosed in childhood, owing to associated cardiac anomalies, such as ventricular septal defect, pulmonary stenosis or pulmonary atresia, and Ebstein-like malformation of the tricuspid valve. We present a patient with congenitally corrected transposition of the great arteries who underwent surgical replacement of the tricuspid valve with a bioprosthesis and reconstruction of the left ventricular outflow tract with bovine conduit.
Aladmawi, Mohamed A; Pragliola, Claudio; Vriz, Olga; Galzerano, Domenico
2017-04-01
Obstruction of a mechanical aortic valve by pannus formation at the subvalvular level is a major long-term complication of aortic valve replacement (AVR). In fact, pannus is sometime difficult to differentiate from patient-prosthesis mismatch or valve thrombosis. In most cases cine-angiography and echocardiography, either transthoracic or transesophageal, cannot correctly visualize the complication when the leaflets show a normal mobility. Recent technological refinements made this difficult diagnosis possible by ECG-gated computed tomography (CT) scan which shows adequate images in 90% of the cases and can differentiate pannus from fresh and organized thrombus.
Yunoki, Junji; Minato, Naoki; Katayama, Yuji; Sato, Hisashi
2009-01-01
We treated a 61-year-old woman with mitral stenosis caused by pannus formation after Duran ring annuloplasty. Pannus overgrowth on the ring with extension onto both leaflets narrowed the mitral orifice and severely restricted the mobility of the valve leaflets. Mitral valve replacement with a St. Jude Medical mechanical heart valve prosthesis was successfully performed, and the postoperative course was uneventful. Patients undergoing Duran ring annuloplasty should be followed up with the consideration of possible mitral stenosis caused by pannus extension, as the cause for pannus formation remains unclear.
Man in his 50s with chest pain and dyspnoea.
Obayashi, Yuki; Izumi, Chisato; Nakagawa, Yoshihisa
2018-05-01
A man in his 50s with sudden-onset chest pain and dyspnoea was transferred to the emergency room. He had a history of aortic valve replacement due to aortic regurgitation with a mechanical valve 6 years previously. Heart rate was 90 bpm, and blood pressure was too low to measure. In the emergency room, he presented with severe dyspnoea and a chest X-ray showed severe lung congestion (figure 1A). ECG showed complete left bundle branch block. His respiratory status rapidly worsened, and he went into cardiopulmonary arrest. After cardiopulmonary resuscitation, transthoracic echocardiography was performed (figure 1B, online supplementary video 1).DC1SP110.1136/heartjnl-2017-312477.supp1Supplementary file 1 heartjnl;104/10/868/F1F1F1Figure 1(A) Chest X-ray. (B) Colour Doppler image from apical five-chamber view. What is the most likely cause of the patient's cardiopulmonary arrest?Myocardial infarction in left main trunkAortic dissectionProsthetic valve thrombosisProsthetic valve embolisationPulmonary embolism. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Hart, Michael A; Shroff, Gautam R
2017-02-17
Infective endocarditis rarely causes mitral valve stenosis. When present, it has the potential to cause severe hemodynamic decompensation and death. There are only 15 reported cases in the literature of mitral prosthetic valve bacterial endocarditis causing stenosis by obstruction. This case is even more unusual due to the mechanism by which functional mitral stenosis occurred. We report a case of a 23-year-old white woman with a history of intravenous drug abuse who presented with acute heart failure. Transthoracic echocardiography failed to show valvular vegetation, but high clinical suspicion led to transesophageal imaging that demonstrated infiltrative prosthetic valve endocarditis causing severe mitral stenosis. Despite extensive efforts from a multidisciplinary team, she died as a result of her critical illness. The discussion of this case highlights endocarditis physiology, the notable absence of stenosis in modified Duke criteria, and the utility of transesophageal echocardiography in clinching a diagnosis. It advances our knowledge of how endocarditis manifests, and serves as a valuable lesson for clinicians treating similar patients who present with stenosis but no regurgitation on transthoracic imaging, as a decision to forego a transesophageal echocardiography could cause this serious complication of endocarditis to be missed.
Buch, W S; Pipkin, R D; Hancock, W D; Fogarty, T J
1975-11-01
From March 1971 through April 1975, one hundred twenty patients underwent mitral valve replacement with a Hancock "stabilized glutaraldehyde process" porcine aortic xenograft. A simultaneous canine experimental series was also carried out. In the clinical series, the early mortality was 8.3%. Actuarial analyses of all patients predicts survival at two years of 81.0% and at four years of 70.0%. The predicted survival for patients without coronary disease or prior prosthetic valve replacement is 87.5% at two years and 77.5% at four years. There were four thromboembolic episodes, a rate of 2.4% per patient-year. None were fatal. No valve failure were noted. Histologic examination and shrink temperature analysis of recovered valves show excellent tissue preservation at 40 months. The data indicate that the Hancock valve is durable, enjoys a low incidence of thromboembolism, and may be the valve of choice for mitral valve replacement.
Abudiab, Muaz M; Chao, Chieh-Ju; Liu, Shuang; Naqvi, Tasneem Z
2017-07-01
Quantitation of regurgitation severity using the proximal isovelocity acceleration (PISA) method to calculate effective regurgitant orifice (ERO) area has limitations. Measurement of three-dimensional (3D) vena contracta area (VCA) accurately grades mitral regurgitation (MR) severity on transthoracic echocardiography (TTE). We evaluated 3D VCA quantitation of regurgitant jet severity using 3D transesophageal echocardiography (TEE) in 110 native mitral, aortic, and tricuspid valves and six prosthetic valves in patients with at least mild valvular regurgitation. The ASE-recommended integrative method comprising semiquantitative and quantitative assessment of valvular regurgitation was used as a reference method, including ERO area by 2D PISA for assigning severity of regurgitation grade. Mean age was 62.2±14.4 years; 3D VCA quantitation was feasible in 91% regurgitant valves compared to 78% by the PISA method. When both methods were feasible and in the presence of a single regurgitant jet, 3D VCA and 2D PISA were similar in differentiating assigned severity (ANOVAP<.001). In valves with multiple jets, however, 3D VCA had a better correlation to assigned severity (ANOVAP<.0001). The agreement of 2D PISA and 3D VCA with the integrative method was 47% and 58% for moderate and 65% and 88% for severe regurgitation, respectively. Measurement of 3D VCA by TEE is superior to the 2D PISA method in determination of regurgitation severity in multiple native and prosthetic valves. © 2017, Wiley Periodicals, Inc.
Signorello, L B; Kennedy, J A; Richmond, R A; Sieu, K L; Blot, W J; Harrison, D C
2001-03-01
The risk of fracture of Björk-Shiley convexo-concave (BSCC) prosthetic heart valves has resulted in consideration of prophylactic explantation and replacement for patients with high-risk valves. Little information exists on perceived quality of life, health status, and serious morbidity among BSCC patients, including those who have undergone explantation. Self-administered questionnaires were completed by a cohort of 585 BSCC patients who participated in an X-ray imaging study to detect precursors to valve fracture up to seven years (average 3.9 years) previously. Responses from 31 explant patients were contrasted with those from 554 BSCC patients in whom explant surgery was not attempted. Perceived quality of life and health status and risk of hospitalization after participating in the imaging study varied considerably among patients, but on average tended not to differ significantly between those with and without explants. A slightly greater proportion of explantees tended to report both improved health status and high rates of heart attack and pacemaker implantation. The health status of these patients was, in general, considerably worse than previously reported among valve implant patients. Over half the cohort were hospitalized during follow up, and half were unable to walk up more than one flight of stairs without shortness of breath. The less than optimal health status of most BSCC patients and relatively high rates of morbidity should be taken into account when considering potential explantation of the valves.
The modern role of transoesophageal echocardiography in the assessment of valvular pathologies
Bull, Sacha; Newton, James
2017-01-01
Despite significant advancements in the field of cardiovascular imaging, transoesophageal echocardiography remains the key imaging modality in the management of valvular pathologies. This paper provides echocardiographers with an overview of the modern role of TOE in the diagnosis and management of valvular disease. We describe how the introduction of 3D techniques has changed the detection and grading of valvular pathologies and concentrate on its role as a monitoring tool in interventional cardiology. In addition, we focus on the echocardiographic and Doppler techniques used in the assessment of prosthetic valves and provide guidance for the evaluation of prosthetic valves. Finally, we summarise quantitative methods used for the assessment of valvular stenosis and regurgitation and highlight the key areas where echocardiography remains superior over other novel imaging modalities. PMID:28096184
The modern role of transoesophageal echocardiography in the assessment of valvular pathologies.
Wamil, Malgorzata; Bull, Sacha; Newton, James
2017-01-17
Despite significant advancements in the field of cardiovascular imaging, transoesophageal echocardiography remains the key imaging modality in the management of valvular pathologies. This paper provides echocardiographers with an overview of the modern role of TOE in the diagnosis and management of valvular disease. We describe how the introduction of 3D techniques has changed detection and grading of valvular pathologies and concentrate on its role as a monitoring tool in interventional cardiology. In addition, we focus on the echocardiographic and Doppler techniques used in the assessment of prosthetic valves, and provide guidance for evaluation of prosthetic valves. Finally, we summarise quantitative methods used for the assessment of valvular stenosis and regurgitation and highlight the key areas where echocardiography remains superior over other novel imaging modalities. © 2017 The authors.
Hemolysis induced by PMIVSD occluder.
Rao, D Sheshagiri; Barik, Ramachandra; Siva Prasad, Akula
2016-09-01
Hemolysis related to occluder, prosthetic valve, and prosthetic ring used for mitral valve annuloplasty are not very unusual. However, hemolysis related to transcathetor closure of post-myocardial infarction ventricular septal defect (PMIVSD) is infrequent. A close follow-up for spontaneous resolution with or without blood transfusion has been reported in a few cases. Occasionally, surgical retrieval is unavoidable or lifelong blood transfusion is required if surgery cannot be done because of higher risk. In this illustration, we have showed a close follow-up of a case of hemolysis induced by atrial septal occluder used for VSD closure after myocardial infarction. Despite successful device closure of PMIVSD which is difficult, a close watch is needed for complications like residual leak, device embolization, and hemolysis. Copyright © 2016 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.
Gilchrist, I C; Cardella, J F; Fox, P S; Pae, W E; el-Ghamry Sabe, A A; Landis, J R; Localio, A R; Kunselman, A R; Hopper, K D
1997-02-01
Cineradiography can identify patients with single-leg fractured Björk-Shiley Convexo-Concave valves, although little is known about the sensitivity and specificity of this technique. We evaluated three normal and six (0 microm gap) single-leg fractured Björk-Shiley valves that were placed in a working phantom model. Valves were randomly imaged a total of 33 times and duplicated into a 120-valve series with a 1:9 ratio of abnormal/normal valves. Six reviewers independently graded each valve and demonstrated markedly different rates of identifying the fractured valves. Average sensitivity at the grade that clinically results in valve explanation was 47%. Among the normal valves, a correct identification was made 96% (range 91% to 99%) of the time. Present radiographic technology may have significant difficulty in identifying true single-leg fracture in Björk-Shiley valves with limb separations that are common among clinically explanted valves.
Cao, Wujing; Yu, Hongliu; Zhao, Weiliang; Li, Jin; Wei, Xiaodong
2018-01-01
Prosthetic knee is the most important component of lower limb prosthesis. Speed adaptive for prosthetic knee during swing flexion is the key method to realize physiological gait. This study aims to discuss the target of physiological gait, propose a speed adaptive control method during swing flexion and research the damping adjustment law of intelligent hydraulic prosthetic knee. According to the physiological gait trials of healthy people, the control target during swing flexion is defined. A new prosthetic knee with fuzzy logical control during swing flexion is designed to realize the damping adjustment automatically. The function simulation and evaluation system of intelligent knee prosthesis is provided. Speed adaptive control test of the intelligent prosthetic knee in different velocities are researched. The maximum swing flexion of the knee angle is set between sixty degree and seventy degree as the target of physiological gait. Preliminary experimental results demonstrate that the prosthetic knee with fuzzy logical control is able to realize physiological gait under different speeds. The faster the walking, the bigger the valve closure percentage of the hydraulic prosthetic knee. The proposed fuzzy logical control strategy and intelligent hydraulic prosthetic knee are effective for the amputee to achieve physiological gait.
Acquired discrete subaortic stenosis late after mitral valve replacement.
Mohan, Jagdish C; Shukla, Madhu; Mohan, Vishwas; Sethi, Arvind
2016-09-01
Although acquired left ventricular outflow obstruction has been reported in a variety of conditions, there are scant reports of its occurrence following mitral valve replacement (MVR). This study describes two female patients, who developed severe discrete subaortic stenosis, five years following MVR. In both cases, the mitral valve was replaced by a porcine Carpentier-Edwards 27-mm bioprosthesis with preservation of mitral valve leaflets. The risk of very late left ventricular outflow tract obstruction after bio-prosthetic MVR with preservation of subvalvular apparatus needs to be kept in mind in symptomatic patients. Copyright © 2016 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.
Intracardiac echocardiography to diagnose pannus formation after aortic valve replacement.
Yamamoto, Yoshiya; Ohara, Takahiro; Funada, Akira; Takahama, Hiroyuki; Amaki, Makoto; Hasegawa, Takuya; Sugano, Yasuo; Kanzaki, Hideaki; Anzai, Toshihisa
2016-03-01
A 66-year-old female, under regular follow-up for 20 years after aortic valve replacement (19-mm Carbomedics), presented dyspnea on effort and hypotension during hemodialysis. A transthoracic echocardiogram showed elevation of transvalvular velocity up to 4 m/s, but the structure around the aortic prosthesis was difficult to observe due to artifacts. Fluoroscopy revealed normal motion of the leaflets of the mechanical valve. Intracardiac echocardiography (ICE) revealed a pannus-like structure in the left ventricular outflow tract. Transesophageal echocardiogram also revealed this structure. ICE can visualize structural abnormalities around a prosthetic valve after cardiac surgery even in patients in whom conventional imaging modalities failed.
Aladmawi, Mohamed A.; Vriz, Olga; Galzerano, Domenico
2017-01-01
Obstruction of a mechanical aortic valve by pannus formation at the subvalvular level is a major long-term complication of aortic valve replacement (AVR). In fact, pannus is sometime difficult to differentiate from patient-prosthesis mismatch or valve thrombosis. In most cases cine-angiography and echocardiography, either transthoracic or transesophageal, cannot correctly visualize the complication when the leaflets show a normal mobility. Recent technological refinements made this difficult diagnosis possible by ECG-gated computed tomography (CT) scan which shows adequate images in 90% of the cases and can differentiate pannus from fresh and organized thrombus. PMID:28540078
Nakamura, Makoto; Muraoka, Arata; Aizawa, Kei; Akutsu, Hirohiko; Kurumisawa, Soki; Misawa, Yoshio
2015-07-01
A 77-year-old man presented with exertional dyspnea. He had undergone aortic and mitral valve replacement with tissue valves 6-years earlier. The patient's hemoglobin level was 9.8 g/dl and serum aspartate aminotransferase (70 mU/ml) and lactate dehydrogenase (1,112 mU/ml) were elevated. Echocardiography revealed stenosis of the prosthetic valve in the aortic position with peak flow velocity of 3.8 m/second and massive mitral regurgitation. The patient underwent repeat valve replacement. Pannus formation around both implanted valves was observed. The aortic valve orifice was narrowed by the pannus, and one cusp of the prosthesis in the mitral position was fixed and caused the regurgitation, but they were free from cusp laceration or calcification. The patient's postoperative course was uneventful, and he continues to do well 14 months after surgery.
Coronary ostia obstruction after replacement of aortic valve prostesis
2011-01-01
Aortic valve replacement (AVR) is the gold standard for the treatment of severe symptomatic aortic stenosis. Complications directly related to surgical procedure are relatively infrequent. Coronary ostial stenosis is, generally, referred as late complication. Anecdotal reports concern coronary ostial stenosis as acute complication. A unique fatal case of intraoperative, bilateral coronary ostial obstruction by prosthetic valve leading to an extensive myocardial infarction is reported. Surgeons must have a high level of vigilance regarding the occurrence of acute myocardial ischemia and sudden death soon after AVR. PMID:21810231
Shibayama, Kentaro; Mihara, Hirotsugu; Jilaihawi, Hasan; Berdejo, Javier; Harada, Kenji; Itabashi, Yuji; Siegel, Robert; Makkar, Raj R; Shiota, Takahiro
2016-02-01
This study of 3-dimensional (3D) transesophageal echocardiography (TEE) aimed to demonstrate features associated with transvalvular aortic regurgitation (AR) after transcatheter aortic valve replacement (TAVR) and to confirm the fact that a gap between the native aortic annulus and prosthesis is associated with paravalvular AR. The mechanism of AR after TAVR, particularly that of transvalvular AR, has not been evaluated adequately. All patients with severe aortic stenosis who underwent TAVR with the Sapien device (Edwards Lifesciences, Irvine, California) had 3D TEE of the pre-procedural native aortic annulus and the post-procedural prosthetic valve. In the 201 patients studied, the total AR was mild in 67 patients (33%), moderate in 21 patients (10%), and severe in no patients. There were 20 patients with transvalvular AR and 82 patients with paravalvular AR. Fourteen patients had both transvalvular and paravalvular AR. Patients with transvalvular AR had larger prosthetic expansion (p <0.05), a more elliptical prosthetic shape at the prosthetic commissure level (p <0.01) and more anti-anatomical position (p <0.001), which was defined as malposition of the prosthetic commissures in relation to the native commissures, than the patients without transvalvular AR. Age (odds ratio [OR]: 1.05; 95% confidence interval [CI]: 1.01 to 1.09; p < 0.05) and effective area oversizing (OR: 0.97; 95% CI: 0.93 to 0.99, p <0.05) were associated with mild or greater paravalvular AR. 3D TEE successfully demonstrated the features associated with transvalvular AR, such as large prosthetic expansion, elliptical prosthetic shape, and anti-anatomical position of prosthesis. Additionally, effective area oversizing was associated with paravalvular AR. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Murashita, Toshifumi; Sugiki, Hiroshi; Kamikubo, Yasuhiro; Yasuda, Keishu
2004-12-01
Surgical treatment of active infective endocarditis requires not only hemodynamic repair, but also special emphasis on the eradication of the infectious focus to prevent recurrence. This goal can be achieved by the combination of aggressive debridement of infective tissue and appropriate and adequate antibiotic treatment. We reviewed our experience with active endocarditis and identified factors determining early and late outcomes, particularly focusing on the factor of culture-negative endocarditis. Sixty seven patients with clinical evidence of active endocarditis who underwent operation between 1991 and 2001 were evaluated. The aortic valve was infected in 28 (42%), the mitral valve in 23 (34%), and multiple valves in 16 (24%). Native valve endocarditis was present in 58 (87%) and prosthetic valve endocarditis in 9 (13%). Mean follow-up was 5.7 years (range, 0.2-11.5 years). Microorganisms were detected in 46 (69%): Staphylococcus aureus in 9 (13%), other staphylococci in 9 (13%), streptococcus species in 19 (28%), and others in 9 (28%), whereas 21 (31%) patients had culture-negative endocarditis. Operative mortality was 17.8% (12 patients). Reoperation was required in 8 (12%), while 3 late deaths (5.5% of hospital survivors) occurred. All events, including death, reoperation, periprosthetic leak, and recurrence of infection, occurred within 2 years after operation. Actuarial freedom from reoperation, late survival, and events at 5 years were 81.6, 76.4, and 68.6%, respectively. On multivariate analysis, no independent adverse predictor was detected for hospital death, whereas the following independent adverse predictors were identified: preoperative heart failure (P=0.0375), prosthetic valve endocarditis (P=0.0391) and culture-negative endocarditis (P=0.0354) for poor late survival; culture-negative endocarditis (P=0.0354) and annular abscess (P=0066) for poor event-free survival. Freedom from events was similar between patients with Staphylococcus aureus infection (3-year freedom 55.6%) and culture-negative endocarditis (3-year freedom 47.6%), whereas events were significantly low in patients with streptococcus infection (3-year freedom 100%). In our analysis, no independent adverse predictor was detected for hospital death; however, culture-negative endocarditis was identified as an independent predictor for both late survival and events after surgery. Event-free survivals were similar between staphylococcus infection and culture-negative endocarditis, and all events occurred within 2 years after operation, suggesting the necessity of close follow-up during that period.
Dysfunction of an On-X Heart Valve by Pannus.
Abad, Cipriano; Urso, Stefano; Gomez, Elsa; De la Vega, Maria
2016-09-01
A 68-year-old woman with a history of previous double-valve replacement with On-X mechanical heart valves presented with clinical, echocardiographic and cardiac catheterization signs of obstruction of the On-X tricuspid heart valve prosthesis. The patient was successfully reoperated, but at surgery the valve was seen to be invaded by an abnormal overgrowth of pannus that blocked one of the leaflets. A small amount of non-obstructive fresh thrombus was also observed. The valve was successfully replaced with a biological heart valve prosthesis. The patient was discharged home, and is doing well four months after the operation, when echocardiography demonstrated normal function in the tricuspid valve. The present case represents the first ever report of pannus formation and subsequent dysfunction in an On-X heart valve, and also the first case of tricuspid valve malfunction and obstruction using this type of heart valve substitute.
Fluid mechanics of heart valves.
Yoganathan, Ajit P; He, Zhaoming; Casey Jones, S
2004-01-01
Valvular heart disease is a life-threatening disease that afflicts millions of people worldwide and leads to approximately 250,000 valve repairs and/or replacements each year. Malfunction of a native valve impairs its efficient fluid mechanic/hemodynamic performance. Artificial heart valves have been used since 1960 to replace diseased native valves and have saved millions of lives. Unfortunately, despite four decades of use, these devices are less than ideal and lead to many complications. Many of these complications/problems are directly related to the fluid mechanics associated with the various mechanical and bioprosthetic valve designs. This review focuses on the state-of-the-art experimental and computational fluid mechanics of native and prosthetic heart valves in current clinical use. The fluid dynamic performance characteristics of caged-ball, tilting-disc, bileaflet mechanical valves and porcine and pericardial stented and nonstented bioprostheic valves are reviewed. Other issues related to heart valve performance, such as biomaterials, solid mechanics, tissue mechanics, and durability, are not addressed in this review.
A bio-inspired microstructure induced by slow injection moulding of cylindrical block copolymers.
Stasiak, Joanna; Brubert, Jacob; Serrani, Marta; Nair, Sukumaran; de Gaetano, Francesco; Costantino, Maria Laura; Moggridge, Geoff D
2014-08-28
It is well known that block copolymers with cylindrical morphology show alignment with shear, resulting in anisotropic mechanical properties. Here we show that well-ordered bi-directional orientation can be achieved in such materials by slow injection moulding. This results in a microstructure, and anisotropic mechanical properties, similar to many natural tissues, making this method attractive for engineering prosthetic fibrous tissues. An application of particular interest to us is prosthetic polymeric heart valve leaflets, mimicking the shape, microstructure and hence performance of the native valve. Anisotropic layers have been observed for cylinder-forming block copolymers centrally injected into thin circular discs. The skin layers exhibit orientation parallel to the flow direction, whilst the core layer shows perpendicularly oriented domains; the balance of skin to core layers can be controlled by processing parameters such as temperature and injection rate. Heart valve leaflets with a similar layered structure have been prepared by injection moulding. Numerical modelling demonstrates that such complex orientation can be explained and predicted by the balance of shear and extensional flow.
Rarity of invasiveness in right-sided infective endocarditis.
Hussain, Syed T; Shrestha, Nabin K; Witten, James; Gordon, Steven M; Houghtaling, Penny L; Tingleff, Jens; Navia, José L; Blackstone, Eugene H; Pettersson, Gösta B
2018-01-01
The rarity of invasiveness of right-sided infective endocarditis (IE) compared with left-sided has not been well recognized and evaluated. Thus, we compared invasiveness of right- versus left-sided IE in surgically treated patients. From January 2002 to January 2015, 1292 patients underwent surgery for active IE, 138 right-sided and 1224 left-sided. Among patients with right-sided IE, 131 had tricuspid and 7 pulmonary valve IE; 12% had prosthetic valve endocarditis. Endocarditis-related invasiveness was based on echocardiographic and operative findings. Invasive disease was rare on the right side, occurring in 1 patient (0.72%; 95% confidence interval 0.02%-4.0%); rather, it was limited to valve cusps/leaflets or was superficial. In contrast, IE was invasive in 408 of 633 patients with aortic valve (AV) IE (65%), 113 of 369 with mitral valve (MV) IE (31%), and 148 of 222 with AV and MV IE (67%). Staphylococcus aureus was a more predominant organism in right-sided than left-sided IE (right 40%, AV 19%, MV 29%), yet invasion was observed almost exclusively on the left side of the heart, which was more common and more severe with AV than MV IE and more common with prosthetic valve endocarditis than native valve IE. Rarity of right-sided invasion even when caused by S aureus suggests that invasion and development of cavities/"abscesses" in patients with IE may be driven more by chamber pressure than organism, along with other reported host-microbial interactions. The lesser invasiveness of MV compared with AV IE suggests a similar mechanism: decompression of MV annulus invasion site(s) toward the left atrium. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Sutherland, R D; Guynes, W A; Nichols, C T; Martinez, H E
1982-01-01
Excessive cage strut wear allowing ball-poppet embolization caused the sudden death of a 47 year old lady in whom a DeBakey-Surgitool aortic prosthesis had been implanted nine years earlier. Patients with this type of prosthesis should have periodic valvular cine fluoroscopy with image intensification to allow visualization of significant strut wear or fracture, and appropriate prosthetic valve replacement.
Short-course thrombolysis as the first line of therapy for cardiac valve thrombosis.
Manteiga, R; Carlos Souto, J; Altès, A; Mateo, J; Arís, A; Dominguez, J M; Borrás, X; Carreras, F; Fontcuberta, J
1998-04-01
To retrospectively evaluate the clinical and echocardiographic criteria of thrombolytic therapy for mechanical heart valve thrombosis. Nineteen consecutive patients with 22 instances of prosthetic heart valve thrombosis (14 mitral, 2 aortic, 3 tricuspid, and 3 pulmonary) were treated with short-course thrombolytic therapy as first option of treatment in absence of contraindications. The thrombolytic therapy protocol consisted of streptokinase (1,500,000 IU in 90 minutes) (n = 18) in one (n = 7) or two (n = 11) cycles or recombinant tissue-type plasminogen activator (100 mg in 90 minutes) (n = 4). Overall success was seen in 82%, immediate complete success in 59%, and partial success in 23%. Six patients without total response to thrombolytic therapy underwent surgery, and pannus was observed in 83%. Six patients showed complications: allergy, stroke, transient ischemic attack, coronary embolism, minor bleeding, and one death. At diagnosis, 10 patients evidenced atrial thrombus by transesophageal echocardiography, 3 of whom experienced peripheral embolism during thrombolysis. Four episodes of rethrombosis were observed (16%). The survivorship was 84% with a mean follow-up of 42.6 months. A short-course of thrombolytic therapy may be considered first-line therapy for prosthetic heart valve thrombosis. The risk of peripheral embolism may be evaluated for the presence of atrial thrombus by transesophageal echocardiography at diagnosis.
Percutaneous re-revalvulation of the tricuspid valve.
Gewillig, Marc; Dubois, Christophe
2011-04-01
We report a successful percutaneous revalvulation of a dysfunctional tricuspid bioprothesis in an 8-year-old child. Five years after implanting a 25-mm Carpentier-Edwards valve in the tricuspid position, the prosthesis showed significant dysfunction with clinical right heart failure. A 26-mm Edwards-Sapien XT inverted aortic valve was successfully implanted through a 19F sheath using a jugular approach. Such procedure can significantly postpone the need for surgical replacement of a biological valve. Copyright © 2011 Wiley-Liss, Inc.
Valve surgery in active infective endocarditis: a simple score to predict in-hospital prognosis.
Martínez-Sellés, Manuel; Muñoz, Patricia; Arnáiz, Ana; Moreno, Mar; Gálvez, Juan; Rodríguez-Roda, Jorge; de Alarcón, Arístides; García Cabrera, Emilio; Fariñas, María C; Miró, José M; Montejo, Miguel; Moreno, Alfonso; Ruiz-Morales, Josefa; Goenaga, Miguel A; Bouza, Emilio
2014-07-15
Surgery for infective endocarditis (IE) is associated with high mortality. Our objectives were to describe the experience with surgical treatment for IE in Spain, and to identify predictors of in-hospital mortality. Prospective cohort of 1000 consecutive patients with IE. Data were collected in 26 Spanish hospitals. Surgery was performed in 437 patients (43.7%). Patients treated with surgery were younger and predominantly male. They presented fewer comorbid conditions and more often had negative blood cultures and heart failure. In-hospital mortality after surgery was lower than in the medical therapy group (24.3 vs 30.7%, p=0.02). In patients treated with surgery, endocarditis involved a native valve in 267 patients (61.1%), a prosthetic valve in 122 (27.9%), and a pacemaker lead with no clear further valve involvement in 48 (11.0%). The most common aetiologies were Staphylococcus (186, 42.6%), Streptococcus (97, 22.2%), and Enterococcus (49, 11.2%). The main indications for surgery were heart failure and severe valve regurgitation. A risk score for in-hospital mortality was developed using 7 prognostic variables with a similar predictive value (OR between 1.7 and 2.3): PALSUSE: prosthetic valve, age ≥ 70, large intracardiac destruction, Staphylococcus spp, urgent surgery, sex [female], EuroSCORE ≥ 10. In-hospital mortality ranged from 0% in patients with a PALSUSE score of 0 to 45.4% in patients with PALSUSE score >3. The prognosis of IE surgery is highly variable. The PALSUSE score could help to identify patients with higher in-hospital mortality. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Ostrovsky, Yury; Spirydonau, Siarhei; Shchatsinka, Mikalai; Shket, Aliaksandr
2015-05-01
Surgical treatment of infective and prosthetic endocarditis using allografts gives good results. Aortic allograft implantation is a common technique, while tricuspid valve replacement with a mitral allograft is very rare. Multiple valve disease in case of infective endocarditis is a surgical challenge as such patients are usually in a grave condition and results of surgical treatment are often unsatisfactory. In this article we describe a clinical case of successful surgical treatment in a patient with active infective endocarditis of aortic and tricuspid valve, complicated by an aortic-right ventricular fistula. The aortic valve and ascending aorta were replaced with a cryopreserved aortic allograft; the tricuspid valve was replaced with a cryopreserved mitral allograft. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Dynamic behavior of prosthetic aortic tissue valves as viewed by high-speed cinematography.
Rainer, W G; Christopher, R A; Sadler, T R; Hilgenberg, A D
1979-09-01
Using a valve testing apparatus of our own design and with a high-speed (600 to 800 frames per second) 16 mm movie camera, films were made of Hancock porcine, Carpentier-Edwards porcine, and Ionescu-Shiley bovine pericardial valves mounted in the aortic position and cycled under physiological conditions at 72 to 100 beats per minute. Fresh and explanted valves were observed using saline or 36.5% glycerol as the pumping solution. When fresh valves were studied using saline solution as the pumpint fluid, the Hancock and Carpentier-Edwards porcine valves showed high-frequency leaflet vibration, which increased in frequency with higher cycling rates. Abnormal leaflet motion was decreased when glycerol was used as the blood analogue. The Ionescu-Shiley bovine pericardial valve did not show abnormal leaflet motion under these conditions. Conclusions drawn from tissue valve testing studies that use excessively high pulsing rates and pressures (accelerated testing) and saline or water as pumping solutions cannot be transposed to predict the fate of tissue valves in a clinical setting.
Loverix, L; Timmermans, P; Benit, E
2013-01-01
We describe a case of a 79-year-old male patient with severe aortic stenosis who underwent transcatheter aortic valve implantation (TAVI) at our institution. He presented at the emergency department with dyspnea and fatigue 7 months after implantation. The diagnosis of early prosthetic valve endocarditis (PVE) caused by Staphylococcus haemolyticus was made by transesophageal echocardiography (TEE) and multiple positive blood cultures. Since our patient was considered inoperable due to a history of coronary artery bypass graft (CABG) surgery with patent bypasses, high peri-operative mortality including renal failure and a poor general prognosis, surgical removal of the valve was not an option. The patient was successfully treated with antibiotic therapy.
Papafaklis, M I; Ligthart, J M R; Vaina, S; Witsenburg, M; Bogers, A J J C; Serruys, P W
2005-01-01
In this case report, we present the use of intracardiac echocardiography (ICE) for guiding the cardiac catheterization and subsequent hemodynamic investigation in an unusual patient case with multiple congenital abnormalities (bicuspid aortic valve, left cervical aortic arch, two aortic coarctations) and two aortic valve replacement operations in the past. The ICE catheter (AcuNav) permitted us to accurately and safely puncture the interatrial septum and place the Swan-Ganz catheter in the left ventricle; additionally, visualization of the aortic coarctation in the ascending aorta was also achieved.
Leaflet embolisation from Duromedics valves: a report of two cases.
Kumar, N; Balasundaram, S; Rickard, M; al Halees, Z; Duran, C M
1991-12-01
Embolization of parts of mechanical valves has been reported since the inception of prosthetic valve implantation. We report here two cases of embolization of one hemileaflet of a Duromedic bileaflet prosthesis in the mitral position due to a pivot fracture. Both presented with moderately severe mitral regurgitation and pulmonary edema and were successfully managed by replacement of the malfunctioning prostheses. The embolised disc was located in the left common iliac artery by abdominal ultrasound and removed by an inguinal, retroperitoneal approach with low morbidity. Both patients left hospital and are doing well to-date.
Yildiz, Mustafa; Duran, Nilüfer Ekşi; Gökdeniz, Tayyar; Kaya, Hasan; Ozkan, Mehmet
2009-09-01
Two-dimensional (2D) echocardiographic approaches are not sufficient to determine the origin of paravalvular leak (PVL) that occurs after prosthetic mitral valve replacement (MVR). In this study, we investigated the role of real-time three-dimensional transesophageal echocardiography (RT-3D TEE) in detecting the origin and size of PVL occurring after prosthetic MVR. The study included 13 patients (7 females; 6 males; mean age 56+/-10 years; range 37 to 71 years) who developed PVL within a mean of 8.3+/-3.8 years following mechanical prosthetic MVR. Nine patients (69.2%) had atrial fibrillation, and four patients (30.8%) had normal sinus rhythm. Four patients (30.8%) had hemolysis. Paravalvular leak was mild, moderate, and severe in two, six, and five patients, respectively. Real-time 3D TEE was performed using a 3D matrix-array TEE transducer immediately after detection of PVL on 2D TEE examination. Localization of PVL was made using a clock-wise format in relation to the aortic valve and the size of dehiscence was measured. The mean PVL width measured by 2D TEE was 3.00+/-0.92 mm. The mean length of dehiscence was 13.6+/-8.8 mm, and the mean width was 3.88+/-2.04 mm on RT-3D TEE. The PVLs were mainly localized in the posterior and anterior annular positions between 12 to 03 hours (n=7) and 06 to 09 hours (n=3) on RT-3D TEE, respectively, which corresponded to the posteromedial or anterolateral sectors of the posterior annulus. Considering that only the width of the PVL defect can be assessed by 2D TEE, delineation by RT-3D TEE includes the localization of PVL together with the length and width of the defect.
Ozkan, Mehmet; Gürsoy, Ozan Mustafa; Astarcıoğlu, Mehmet Ali; Gündüz, Sabahattin; Cakal, Beytullah; Karakoyun, Süleyman; Kalçık, Macit; Kahveci, Gökhan; Duran, Nilüfer Ekşi; Yıldız, Mustafa; Cevik, Cihan
2013-10-01
Although 2-dimensional (2D) transesophageal echocardiography (TEE) is the gold standard for the diagnosis of prosthetic valve thrombosis, nonobstructive clots located on mitral valve rings can be missed. Real-time 3-dimensional (3D) TEE has incremental value in the visualization of mitral prosthesis. The aim of this study was to investigate the utility of real-time 3D TEE in the diagnosis of mitral prosthetic ring thrombosis. The clinical outcomes of these patients in relation to real-time 3D transesophageal echocardiographic findings were analyzed. Of 1,263 patients who underwent echocardiographic studies, 174 patients (37 men, 137 women) with mitral ring thrombosis detected by real-time 3D TEE constituted the main study population. Patients were followed prospectively on oral anticoagulation for 25 ± 7 months. Eighty-nine patients (51%) had thrombi that were missed on 2D TEE and depicted only on real-time 3D TEE. The remaining cases were partially visualized with 2D TEE but completely visualized with real-time 3D TEE. Thirty-seven patients (21%) had thromboembolism. The mean thickness of the ring thrombosis in patients with thromboembolism was greater than that in patients without thromboembolism (3.8 ± 0.9 vs 2.8 ± 0.7 mm, p <0.001). One hundred fifty-five patients (89%) underwent real-time 3D TEE during follow-up. There were no thrombi in 39 patients (25%); 45 (29%) had regression of thrombi, and there was no change in thrombus size in 68 patients (44%). Thrombus size increased in 3 patients (2%). Thrombosis was confirmed surgically and histopathologically in 12 patients (7%). In conclusion, real-time 3D TEE can detect prosthetic mitral ring thrombosis that could be missed on 2D TEE and cause thromboembolic events. Copyright © 2013 Elsevier Inc. All rights reserved.
Cerebral hemorrhage in infective endocarditis caused by Actinobacillus actinomycetemcomitans.
Lin, Gen-Min; Chu, Kai-Min; Juan, Chun-Jung; Chang, Feng-Yee
2007-11-01
Cerebral hemorrhage occurs rarely in endocarditis caused by Actinobacillus actinomycetemcomitans. A 51-year-old man with a prosthetic mitral valve, who had been prophylactically treated (7 years) with warfarin, presented with intermittent fever. On admission, a Levine grade II/VI systolic cardiac murmur was detected. A transthoracic echocardiogram was negative for valve vegetation. Cefepime (1 g every 8 hours) was administered intravenously. On day 4, culturing of Gram-negative bacilli from blood and a transesophageal echocardiogram revealed a small oscillating filament attached to lateral mitral prosthetic ring on the atrial side. Ceftriaxone (2 g once daily) was started. Gait instability and left-side weakness developed abruptly 2 weeks later; brain magnetic resonance imaging revealed a hematoma over the right parietal-occipital lobe. Ceftriaxone was adjusted to 2 g every 12 hours. Actinobacillus actinomycetemcomitans was identified 3 weeks later. Recovery was achieved, with significant interval improvement and resolution of the cerebral lesions evident on CT.
Kohler, Philipp; Kuster, Stefan P; Bloemberg, Guido; Schulthess, Bettina; Frank, Michelle; Tanner, Felix C; Rössle, Matthias; Böni, Christian; Falk, Volkmar; Wilhelm, Markus J; Sommerstein, Rami; Achermann, Yvonne; Ten Oever, Jaap; Debast, Sylvia B; Wolfhagen, Maurice J H M; Brandon Bravo Bruinsma, George J; Vos, Margreet C; Bogers, Ad; Serr, Annerose; Beyersdorf, Friedhelm; Sax, Hugo; Böttger, Erik C; Weber, Rainer; van Ingen, Jakko; Wagner, Dirk; Hasse, Barbara
2015-10-21
We identified 10 patients with disseminated Mycobacterium chimaera infections subsequent to open-heart surgery at three European Hospitals. Infections originated from the heater-cooler unit of the heart-lung machine. Here we describe clinical aspects and treatment course of this novel clinical entity. Interdisciplinary care and follow-up of all patients was documented by the study team. Patients' characteristics, clinical manifestations, microbiological findings, and therapeutic measures including surgical reinterventions were reviewed and treatment outcomes are described. The 10 patients comprise a 1-year-old child and nine adults with a median age of 61 years (range 36-76 years). The median duration from cardiac surgery to diagnosis was 21 (range 5-40) months. All patients had prosthetic material-associated infections with either prosthetic valve endocarditis, aortic graft infection, myocarditis, or infection of the prosthetic material following banding of the pulmonary artery. Extracardiac manifestations preceded cardiovascular disease in some cases. Despite targeted antimicrobial therapy, M. chimaera infection required cardiosurgical reinterventions in eight patients. Six out of 10 patients experienced breakthrough infections, of which four were fatal. Three patients are in a post-treatment monitoring period. Healthcare-associated infections due to M. chimaera occurred in patients subsequent to cardiac surgery with extracorporeal circulation and implantation of prosthetic material. Infections became clinically apparent after a time lag of months to years. Mycobacterium chimaera infections are easily missed by routine bacterial diagnostics and outcome is poor despite long-term antimycobacterial therapy, probably because biofilm formation hinders eradication of pathogens. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Han, Kichang; Yang, Dong Hyun; Shin, So Youn; Kim, Namkug; Kang, Joon-Won; Kim, Dae-Hee; Song, Jong-Min; Kang, Duk-Hyun; Song, Jae-Kwan; Kim, Joon Bum; Jung, Sung-Ho; Choo, Suk Jung; Chung, Cheol Hyun; Lee, Jae Won; Lim, Tae-Hwan
2015-09-01
To investigate the cardiac computed tomographic (CT) findings and clinical implications of subprosthetic pannus in patients who have undergone aortic valve replacement. The institutional review board approved this retrospective study, and the need to obtain written informed consent was waived. From April 2011 to March 2012, 88 patients (mean age, 63 years; 45 men) with a prosthetic aortic valve who underwent cardiac CT were retrospectively selected. Dynamic cardiac CT images were analyzed by using a multiplanar reformatted technique. The presence or absence of subprosthetic pannus and its extent were evaluated at cardiac CT. The geometric orifice area and the effective orifice area of each prosthetic valve were measured to enable analysis of the pannus encroachment ratio in the systolic phase. Hemodynamic parameters at echocardiography, including mean transprosthetic pressure gradient (MTPG), were compared between patients with and those without pannus. The encroachment ratio and the MTPG were correlated by using the Spearman test to evaluate the relationship between the two variables. Seventeen patients (19%) had subprosthetic pannus at cardiac CT. In patients with subprosthetic pannus, MTPG, peak pressure gradient, transvalvular peak velocity, and left ventricular ejection fraction (LVEF) were significantly higher than in patients without pannus (MTPG: 28.1 mm Hg ± 19.8 [standard deviation] vs 14.0 mm Hg ± 6.5, P = .004; peak pressure gradient: 53.1 mm Hg ± 38.4 vs 26.1 mm Hg ± 11.4, P = .004; transvalvular peak velocity: 3.3 m/sec ± 1.3 vs 2.5 m/sec ± 0.5; and LVEF: 64.7% ± 7.4 vs 56.8% ± 10.5, P = .004). A high MTPG (≥40 mm Hg) was observed in four patients at echocardiography, and subprosthetic panni were identified at CT in all four patients. In patients with increased MTPGs, the encroachment ratio by subprosthetic pannus at CT was significantly higher than that in patients with MTPGs of less than 40 mm Hg (42.7 ± 13.3 vs 7.6 ± 3, P = .012). Cardiac CT revealed subprosthetic pannus to be a cause of the hemodynamic changes in patients who had undergone aortic valve replacement. By helping quantify the encroachment ratio by pannus, cardiac CT may help differentiate which subprosthetic panni might lead to substantial flow limitation over the prosthetic aortic valve.
Roubelakis, Apostolos; Karangelis, Dimos; Sadeque, Syed; Yanagawa, Bobby; Modi, Amit; Barlow, Clifford W; Livesey, Steven A; Ohri, Sunil K
2017-07-01
The treatment of complex prosthetic valve endocarditis (PVE) with aortic root abscess remains a surgical challenge. Several studies support the use of biological tissues to minimize the risk of recurrent infection. We present our initial surgical experience with the use of an aortic xenograft conduit for aortic valve and root replacement. Between October 2013 and August 2015, 15 xenograft bioconduits were implanted for complex PVE with abscess (13.3% female). In 6 patients, concomitant procedures were performed: coronary bypass (n=1), mitral valve replacement (n=5) and tricuspid annuloplasty (n=1). The mean age at operation was 60.3±15.5 years. The mean Logistic European system for cardiac operating risk evaluation (EuroSCORE) was 46.6±23.6. The median follow-up time was 607±328 days (range: 172-1074 days). There were two in-hospital deaths (14.3% mortality), two strokes (14.3%) and seven patients required permanent pacemaker insertion for conduction abnormalities (46.7%). The mean length of hospital stay was 26 days. At pre-discharge echocardiography, the conduit mean gradient was 9.3±3.3mmHg and there was either none (n=6), trace (n=6) or mild aortic insufficiency (n=1). There was no incidence of mid-term death, prosthesis-related complications or recurrent endocarditis. Xenograft bioconduits may be safe and effective for aortic valve and root replacement for complex PVE with aortic root abscess. Although excess early mortality reflects the complexity of the patient population, there was good valve hemodynamics, with no incidence of recurrent endocarditis or prosthesis failure in the mid-term. Our data support the continued use and evaluation of this biological prosthesis in this high-risk patient cohort.
Healthcare-Associated Infective Endocarditis: a Case Series in a Referral Hospital from 2006 to 2011
Francischetto, Oslan; da Silva, Luciana Almenara Pereira; Senna, Katia Marie Simões e; Vasques, Marcia Regina; Barbosa, Giovanna Ferraiuoli; Weksler, Clara; Ramos, Rosana Grandelle; Golebiovski, Wilma Felix; Lamas, Cristiane da Cruz
2014-01-01
Background Healthcare-associated infective endocarditis (HCA-IE), a severe complication of medical care, shows a growing incidence in literature. Objective To evaluate epidemiology, etiology, risk factors for acquisition, complications, surgical treatment, and outcome of HCA-IE. Methods Observational prospective case series study (2006-2011) in a public hospital in Rio de Janeiro. Results Fifty-three patients with HCA-IE from a total of 151 cases of infective endocarditis (IE) were included. There were 26 (49%) males (mean age of 47 ± 18.7 years), 27 (51%) females (mean age of 42 ± 20.1 years). IE was acute in 37 (70%) cases and subacute in 16 (30%) cases. The mitral valve was affected in 19 (36%) patients and the aortic valve in 12 (36%); prosthetic valves were affected in 23 (43%) patients and native valves in 30 (57%). Deep intravenous access was used in 43 (81%) cases. Negative blood cultures were observed in 11 (21%) patients, Enterococcus faecalis in 10 (19%), Staphylococcus aureus in 9 (17%), and Candida sp. in 7 (13%). Fever was present in 49 (92%) patients, splenomegaly in 12 (23%), new regurgitation murmur in 31 (58%), and elevated C-reactive protein in 44/53 (83%). Echocardiograms showed major criteria in 46 (87%) patients, and 34 (64%) patients were submitted to cardiac surgery. Overall mortality was 17/53 (32%). Conclusion In Brazil HCA-IE affected young subjects. Patients with prosthetic and native valves were affected in a similar proportion, and non-cardiac surgery was an infrequent predisposing factor, whereas intravenous access was a common one. S. aureus was significantly frequent in native valve HCA-IE, and overall mortality was high. PMID:25352503
Structural valve deterioration in a starr-edwards mitral caged-disk valve prosthesis.
Aoyagi, Shigeaki; Tayama, Kei-Ichiro; Okazaki, Teiji; Shintani, Yusuke; Kono, Michitaka; Wada, Kumiko; Kosuga, Ken-Ichi; Mori, Ryusuke; Tanaka, Hiroyuki
2013-01-01
The durability of the Starr-Edwards (SE) mitral caged-disk valve, model 6520, is not clearly known, and structural valve deterioration in the SE disk valve is very rare. Replacement of the SE mitral disk valve was performed in 7 patients 23-40 years after implantation. Macroscopic examination of the removed disk valves showed no structural abnormalities in 3 patients, in whom the disk valves were removed at <26 years after implantation. Localized disk wear was found at the sites where the disk abutted the struts of the cage, in disk valves excised >36 years after implantation in 4 patients. Disk fracture, a longitudinal split in the disk along its circumference at the site of incorporation of the titanium ring, was detected in the valves removed 36 and 40 years after implantation, respectively, and many cracks were also observed on the outflow aspect of the disk removed 40 years after implantation. Disk fracture and localized disk wear were found in the SE mitral disk valves implanted >36 years previously. The present results suggest that SE mitral caged-disk valves implanted >20 years previously should be carefully followed up, and that those implanted >30 years previously should be electively replaced with modern prosthetic valves
HWANG, HUI-JEONG; YOON, KYUNG LIM; SOHN, IL SUK
2016-01-01
The present study reported the case of a 60-year-old female with patent ductus arteriosus (PDA) and a bicuspid aortic valve, who presented with transient severe left ventricular (LV) dysfunction following percutaneous closure of PDA, as identified by speckle tracking analysis. Transient LV dysfunction following PDA closure has previously been reported; however, severe LV dysfunction is rare. In the present case, the combination of a large PDA size, large amount of shunting, LV remodeling and bicuspid aortic valve may have induced serious deterioration of LV function following PDA closure. Furthermore, speckle-tracking echocardiography may be useful in the estimation of functional alterations in the myocardium of the LV following PDA closure. The observations detailed in the present study may improve the understanding of the pathophysiology and myocardial patterns of transient left ventricular dysfunction following PDA closure in adult humans. PMID:26998021
Hwang, Hui-Jeong; Yoon, Kyung Lim; Sohn, Il Suk
2016-03-01
The present study reported the case of a 60-year-old female with patent ductus arteriosus (PDA) and a bicuspid aortic valve, who presented with transient severe left ventricular (LV) dysfunction following percutaneous closure of PDA, as identified by speckle tracking analysis. Transient LV dysfunction following PDA closure has previously been reported; however, severe LV dysfunction is rare. In the present case, the combination of a large PDA size, large amount of shunting, LV remodeling and bicuspid aortic valve may have induced serious deterioration of LV function following PDA closure. Furthermore, speckle-tracking echocardiography may be useful in the estimation of functional alterations in the myocardium of the LV following PDA closure. The observations detailed in the present study may improve the understanding of the pathophysiology and myocardial patterns of transient left ventricular dysfunction following PDA closure in adult humans.
Late complications in patients with Björk-Shiley and St. Jude Medical heart valve replacement.
Horstkotte, D; Körfer, R; Seipel, L; Bircks, W; Loogen, F
1983-09-01
Valve-related complications after Björk-Shiley mitral valve implantation (n = 475), aortic valve implantation (n = 424), or mitral-aortic valve implantation (n = 119) were compared with those after St. Jude Medical mitral valve replacement (n = 173), aortic valve replacement (n = 152), or mitral-aortic valve replacement (n = 69). All patients were placed on anticoagulant therapy with phenprocoumon early after operation. All patients had a comparable follow-up time of approximately 23 months, which showed that cumulative thromboembolic rates were significantly higher after St. Jude valve implantation than after Björk-Shiley valve implantation. Reoperations were necessary because of valve thrombosis (0.46%), perivalvular leakage (2.2%), or prosthetic valve endocarditis with perivalvular regurgitation (0.46%). One Björk-Shiley mitral valve prosthesis had to be replaced because of fracture of the outlet strut. Without significant intergroup differences, hemorrhage due to anticoagulant treatment was the most frequent complication. Thromboembolic complications were significantly more frequent after Björk-Shiley mitral, aortic, and double valve replacements than after St. Jude valve implantation. This may lead to consideration of changes in the prophylaxis of thrombus formations in the St. Jude valve, especially in aortic valve replacements, in patients with sinus rhythm.
Ishii, K; Koga, Y; Maeda, M; Nakamura, K; Sekiya, R; Yonezawa, T; Onitsuka, T; Shibata, K
1988-01-01
A 70-year-old male with tricuspid regurgitation due to a blunt chest trauma inflicted 16 years previously underwent prosthetic valve replacement. At surgery, a tear, which produced tricuspid regurgitation, was found around the annulus of the anterior leaflet of the tricuspid valve. Since this area has not been reported as a location for heart trauma-producing tricuspid regurgitation, a possible mechanism of tricuspid regurgitation is discussed in this patient.
Computerized system for the follow-up of patients with heart valve replacements.
Bain, W H; Fyfe, I C; Rodger, R A
1985-04-01
A system is described which will accept, store, retrieve and analyze information on large numbers of patients who undergo valve replacement surgery. The purpose of the database is to yield readily available facts concerning the patient's clinical course, prosthetic valve function, length of survival, and incidence of complications. The system uses the Apple Macintosh computer, which is one of the current examples of small, desk-top microprocessors. The software for the input, editing and analysis programs has been written by a professional software writer in close collaboration with a cardiac surgeon. Its content is based on 8 years' experience of computer-based valve follow-up. The system is inexpensive and has proved easy to use in practice.
Visualizing anatomical evidences on atrioventricular conduction system for TAVI.
Kawashima, Tomokazu; Sato, Fumi
2014-06-01
Visualizing the anatomy of the atrioventricular (AV) conduction axis substantiates that there is remarkable inter-individual variation at the macro- and microscopic levels, and that the atrioventricular bundle and left bundle branch are located more anteriorly, distally, and cranially and much closer to the aortic root complex than previously thought. The AV conduction system may therefore be compromised during implantation of a transcatheter aortic valve prosthesis, which may account for the relatively high incidence of new cardiac conduction abnormalities when conventional prosthetic valves are used. The design of the newer JenaValve® may afford advantages over more conventional valves by avoiding the high-risk implantation area and the potential for coronary ostia obstruction. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
The Ross operation: a 12-year experience.
Elkins, R C
1999-09-01
The Ross operation, originally introduced as a scalloped subcoronary implant with an 80% survival and 85% freedom from reoperation, has recently been modified to a root replacement which is now the most utilized implant technique. The mid and late results of this operative technique and comparison of intra-aortic implants and root replacement in a single institution are reported. The records of 328 patients who had a Ross operation at the University of Oklahoma (August 1986 to July 1998) were reviewed to assess operative technique and patient-related factors on survival, autograft valve function, homograft valve function, valve-related complications, and need for reoperation. Operative survival was 95.4% with an actuarial survival of 89% +/- 5% at 8 years. Freedom from replacement of the pulmonary autograft was 94% +/- 3% at 8 years, freedom from reoperation on the pulmonary homograft was 90% +/- 4% at 8 years, and freedom from autograft valve reoperation or dysfunction (3+ autograft valve insufficiency) was 83% +/- 6% at 9 years. The incidence of autograft valve reoperation and late autograft valve dysfunction was decreased by root replacement. Annulus reduction and fixation improved early results in patients with aortic insufficiency and annulus dilatation. Early results have been excellent, as the development of late autograft valve dysfunction or dilatation has been rare. The excellent hemodynamic results with a limited incidence of reoperation and replacement of the autograft valve justify its continued use.
[Clinical Characteristics and Evolution of Recurrent Infectious Endocarditis in non Drug Addicts].
Rodríguez, M; Anguita, M; Castillo, J M; Torres, F; Siles, J R; Mesa, D; Franco, M; García-Alegría, J; Concha, M; Vallés, F
2001-09-01
Recurrence of infection is observed in a high proportion of patients who have had infective endocarditis in the past. The aim of our study was to evaluate the possible differences between the first and the recurrent episodes of endocarditis, as well as to assess the outcome and prognosis of patients with recurrent endocarditis. We reviewed a series of 13 episodes of recurrent endocarditis from among 196 cases of infective endocarditis involving non-drug-addict patients in two hospitals from 1987 to 2000. There were no differences between recurrent and first episodes of endocarditis according to age, sex, heart valve involved or causal microorganisms. Prosthetic valve endocarditis was more common in patients with recurrent endocarditis (86% versus 27%; p < 0.001). Although there were no differences in the rate of complications or early surgery, overall mortality was significantly higher in patients with recurrent endocarditis (53% versus 27%: p < 0.05). When early and late mortality were analysed separately, the differences did not achieve significance. Recurrent endocarditis was frequent in our series (7% of all cases). The features were similar to those of the first episode except for a higher rate of prosthetic valve endocarditis and a higher overall mortality.
Gamakaranage, Champika; Rodrigo, Chaturaka; Samarawickrama, Sincy; Wijayaratne, Dilushi; Jayawardane, Malaka; Karunanayake, Panduka; Jayasinghe, Saroj
2012-10-26
Managing a severe dengue infection is a challenge specially when complicated by other comorbidities. We report a patient with dengue haemorrhagic fever and spontaneous bleeding who required mandatory anticoagulation for a prosthetic mitral valve replacement. This is the first case report in published literature describing this therapeutic dilemma. A fifty one year old Sri Lankan woman was diagnosed with dengue haemorrhagic fever with bleeding manifestations. During the critical phase of her illness, the platelet count dropped to 5,000/ɥl. She was also on warfarin 7 mg daily following a prosthetic mitral valve insertion. In managing the patient, the risk of bleeding had to be balanced against the risk of valve thrombosis without anticoagulation. Warfarin was withheld when the platelet count dropped to 100,000/ɥl and restarted when it recovered above 50,000/ɥl. The patient was off anticoagulation for 10 days. We managed this patient with close observation and continuous risk benefit assessments of management decisions. However, experience with one patient cannot be generalized to others. Therefore, it is essential that clinicians share their experiences in managing such difficult patients.
Outcome of bioprosthetic valve replacement in dogs with tricuspid valve dysplasia.
Bristow, P; Sargent, J; Luis Fuentes, V; Brockman, D
2017-04-01
To describe the short-term and long-term outcome in dogs with tricuspid valve dysplasia undergoing tricuspid valve replacement under cardiopulmonary bypass. Data were collected from the hospital records of all dogs that had undergone tricuspid valve replacement under cardiopulmonary bypass between 2006 and 2012. Dogs were considered candidates for tricuspid valve replacement if they had severe tricuspid valve regurgitation associated with clinical signs of cardiac compromise. Nine dogs of six different breeds were presented. Median age was 13 months (range 7 to 61 months), median weight 26·5 kg (range 9·7 to 59 kg). Eight bovine pericardial valves and one porcine aortic valve were used. One non-fatal intraoperative complication occurred. Complications during hospitalisation occurred in six dogs, four of which were fatal. Of the five dogs discharged, one presented dead due to haemothorax after minor trauma seven days later. The four remaining dogs survived a median of 533 days; all of these dogs received a bovine pericardial valve. Based on our results, tricuspid valve replacement with bovine or porcine prosthetic valves is associated with a high incidence of complications. © 2017 British Small Animal Veterinary Association.
Roberts, William Clifford; Vowels, Travis James; Ko, Jong Mi; Filardo, Giovanni; Hebeler, Robert Frederick; Henry, Albert Carl; Matter, Gregory John; Hamman, Baron Lloyd
2011-03-01
There is debate concerning whether an aneurysmal ascending aorta should be replaced when associated with a dysfunctioning aortic valve that is to be replaced. To examine this issue, we divided the patients by type of aortic valve dysfunction-either aortic stenosis (AS) or pure aortic regurgitation (AR)-something not previously undertaken. Of 122 patients with ascending aortic aneurysm (unassociated with aortitis or acute dissection), the aortic valve was congenitally malformed (unicuspid or bicuspid) in 58 (98%) of the 59 AS patients, and in 38 (60%) of the 63 pure AR patients. Ascending aortic medial elastic fiber loss (EFL) (graded 0 to 4+) was zero or 1+ in 53 (90%) of the AS patients, in 20 (53%) of the 38 AR patients with bicuspid valves, and in all 12 AR patients with tricuspid valves unassociated with the Marfan syndrome. An unadjusted analysis showed that, among the 96 patients with congenitally malformed valves, the 38 AR patients had a significantly higher likelihood of 2+ to 4+ EFL than the 58 AS patients (crude odds ratio: 8.78; 95% confidence interval: 2.95, 28.13). These data strongly suggest that the type of aortic valve dysfunction-AS versus pure AR-is very helpful in predicting loss of aortic medial elastic fibers in patients with ascending aortic aneurysms and aortic valve disease.
A technique of snaring method for fitting a prosthetic valve into the annulus.
Nagasaka, Shigeo; Kawata, Tetsuji; Matsuta, Masahiro; Taniguchi, Shigeki
2005-01-01
Tourniquetting technique to fit a prosthetic valve (PV) into the annulus in valve replacement surgery has been previously reported. We modified the previously reported method and designed a simpler tying technique. We performed 11 aortic (AVR: including four cases for calcified aortic stenosis (AS) with a small annulus and one cases for infective endocarditis with intramuscular abscess cavity), eight mitral valve replacements (MVR), and one tricuspid valve replacement (TVR: for corrected transposition of the great arteries). A PV was implanted using 2-0 polyester mattress sutures with a pledget. Each of the two tourniquets held a suture at the bottom of the annulus and at the opposite position to fit a PV. The sutures between each snare were tied down from the bottom to the top. In MVR, after seating of a PV with two tourniquets, we could make sure that no native tissue of any preserved mitral apparatus disturbed PV leaflet motion. In calcific AS, a PV had a good fitting into the annulus because of tourniquets applied to unseated part during tying sutures. In AVR for infective endocarditis, mattress sutures supported by a Teflon pledget were placed to close the abscess cavity. After snaring on one of these sutures, we tied down the sutures, ensuring that they did not cut through the friable tissues. In TVR, we found that native leaflets interfered with PV motion after seating down the prosthesis and those leaflets were resected before tying down the sutures. Postoperative transesophageal echocardiography showed no paravalvular leakage in any patients and excellent PV functions.
Evolution of penile prosthetic devices
Burnett, Arthur L.
2015-01-01
Penile implant usage dates to the 16th century yet penile implants to treat erectile dysfunction did not occur until nearly four centuries later. The modern era of penile implants has progressed rapidly over the past 50 years as physicians' knowledge of effective materials for penile prostheses and surgical techniques has improved. Herein, we describe the history of penile prosthetics and the constant quest to improve the technology. Elements of the design from the first inflatable penile prosthesis by Scott and colleagues and the Small-Carrion malleable penile prosthesis are still found in present iterations of these devices. While there have been significant improvements in penile prosthesis design, the promise of an ideal prosthetic device remains elusive. As other erectile dysfunction therapies emerge, penile prostheses will have to continue to demonstrate a competitive advantage. A particular strength of penile prostheses is their efficacy regardless of etiology, thus allowing treatment of even the most refractory cases. PMID:25763121
Evolution of penile prosthetic devices.
Le, Brian; Burnett, Arthur L
2015-03-01
Penile implant usage dates to the 16th century yet penile implants to treat erectile dysfunction did not occur until nearly four centuries later. The modern era of penile implants has progressed rapidly over the past 50 years as physicians' knowledge of effective materials for penile prostheses and surgical techniques has improved. Herein, we describe the history of penile prosthetics and the constant quest to improve the technology. Elements of the design from the first inflatable penile prosthesis by Scott and colleagues and the Small-Carrion malleable penile prosthesis are still found in present iterations of these devices. While there have been significant improvements in penile prosthesis design, the promise of an ideal prosthetic device remains elusive. As other erectile dysfunction therapies emerge, penile prostheses will have to continue to demonstrate a competitive advantage. A particular strength of penile prostheses is their efficacy regardless of etiology, thus allowing treatment of even the most refractory cases.
Biomaterial-host interactions: consequences, determined by implant retrieval analysis.
Kaplan, S S
1994-01-01
Prosthetic biomaterials have had a profound impact on reconstructive surgery but complete biocompatability remains illusive. This review considers the retrieval analysis of four common prosthetic structures: the hip, the knee, heart valves, and blood vessels. We show that despite a fine record of early success, deterioration due to mechanical failure or deleterious host responses to the implant may compromise long term function. The eventual retrieval and detailed analysis of implanted structures provides an invaluable opportunity to determine the characteristics of implant success or failure and to provoke the development of still better materials.
Development and marketing of a prosthetic urinary control valve system
NASA Technical Reports Server (NTRS)
Tenney, J. B., Jr.; Rabinowitz, R.; Rogers, D. W.; Harrison, H. N.
1983-01-01
An implantable prosthetic for the control of urinary incontinence was developed and marketed. Three phases are presented: bench development studies, animal trials, and human clinical trials. This work was performed under the direction of a Research Team at Rochester General Hospital (RGH). Bench trials were completed on prototype hardware and provided early verification of the device's ability to withstand repeated cyclic testing. Configurational variants were evaluated and a preferred design concept was established. Silicone rubber (medical grade) was selected as the preferred material for the prosthesis.
Intraoperative echocardiography of a dislodged Björk-Shiley mitral valve disc.
Tanaka, M; Abe, T; Takeuchi, E; Watanabe, T; Tamaki, S
1991-02-01
The successful management of a patient who suffered an outlet strut fracture of a Björk-Shiley 60-degree convexo-concave mitral valve prosthesis is reported. Emergency operation was life-saving. Preoperative echocardiography assisted in making a prompt diagnosis, and intraoperative echocardiography allowed the detection and removal of the dislodged disc from the left ventricle at the time of the operation. The role of intraoperative echocardiography in the diagnosis of prosthetic strut fracture is emphasized.
Effect of the prosthetic mitral valve on vortex dynamics and turbulence of the left ventricular flow
NASA Astrophysics Data System (ADS)
Querzoli, G.; Fortini, S.; Cenedese, A.
2010-04-01
Mechanical heart valves implanted in mitral position have a great effect on the ventricular flow. Changes include alteration of the dynamics of the vortical structures generated during the diastole and the onset of turbulence, possibly affecting the efficiency of the heart pump or causing blood cell damage. Modifications to the hemodynamics in the left ventricle, when the inflow through the mitral orifice is altered, were investigated in vitro using a silicone rubber, flexible ventricle model. Velocity fields were measured in space and time by means of an image analysis technique: feature tracking. Three series of experiments were performed: one with a top hat inflow velocity profile (schematically resembling physiological conditions), and two with mechanical prosthetic valves of different design, mounted in mitral position—one monoleaflet and the other bileaflet. In each series of runs, two different cardiac outputs have been examined by changing the stroke volume. The flow was investigated in terms of phase averaged velocity field and second order moments of turbulent fluctuations. Results show that the modifications in the transmitral flow change deeply the interaction between the coherent structures generated during the first phase of the diastole and the incoming jet during the second diastolic phase. Top hat inflow gives the coherent structures which are optimal, among the compared cases, for the systolic function. The flow generated by the bileaflet valve preserves most of the beneficial features of the top hat inflow, whereas the monoleaflet valve generates a strong jet which discourages the permanence of large coherent structures at the end of the diastole. Moreover, the average shear rate magnitudes induced by the smoother flow pattern of the case of top hat inflow are nearly halved in comparison with the values measured with the mechanical valves. Finally, analysis of the turbulence statistics shows that the monoleaflet valves yield higher turbulence intensity in comparison with the bileaflet and, with top hat inflow, there is not a complete transition to turbulence.
Aortic valve dysfunction and aortic dilation in adults with coarctation of the aorta.
Clair, Mathieu; Fernandes, Susan M; Khairy, Paul; Graham, Dionne A; Krieger, Eric V; Opotowsky, Alexander R; Singh, Michael N; Colan, Steven D; Meijboom, Erik J; Landzberg, Michael J
2014-01-01
To determine the prevalence of aortic valve dysfunction, aortic dilation, and aortic valve and ascending aortic intervention in adults with coarctation of the aorta (CoA). Aortic valve dysfunction and aortic dilation are rare among children and adolescents with CoA. With longer follow-up, adults may be more likely to have progressive disease. We retrospectively reviewed all adults with CoA, repaired or unrepaired, seen at our center between 2004 and 2010. Two hundred sixteen adults (56.0% male) with CoA were identified. Median age at last evaluation was 28.3 (range 18.0 to 75.3) years. Bicuspid aortic valve (BAV) was present in 65.7%. At last follow-up, 3.2% had moderate or severe aortic stenosis, and 3.7% had moderate or severe aortic regurgitation. Dilation of the aortic root or ascending aorta was present in 28.0% and 41.6% of patients, respectively. Moderate or severe aortic root or ascending aortic dilation (z-score > 4) was present in 8.2% and 13.7%, respectively. Patients with BAV were more likely to have moderate or severe ascending aortic dilation compared with those without BAV (19.5% vs. 0%; P < 0.001). Age was associated with ascending aortic dilation (P = 0.04). At most recent follow-up, 5.6% had undergone aortic valve intervention, and 3.2% had aortic root or ascending aortic replacement. In adults with CoA, significant aortic valve dysfunction and interventions during early adulthood were uncommon. However, aortic dilation was prevalent, especially of the ascending aorta, in patients with BAV. © 2013 Wiley Periodicals, Inc.
Long-Term Results of Aortic Root Surgery in Marfan Syndrome Patients: A Single-Center Experience.
Nicolo, Francesco; Romeo, Francesco; Lio, Antonio; Bovio, Emanuele; Scafuri, Antonio; Bassano, Carlo; Polisca, Patrizio; Pellegrino, Antonio; Nardi, Paolo; Chiariello, Luigi; Ruvolo, Giovanni
2017-07-01
The study aim was to compare long-term results of Marfan syndrome (MFS) patients affected by aortic root disease undergoing aortic root replacement with the Bentall or David operation. Since 1994, a total of 59 patients has been followed at the authors' Marfan Center, having undergone either a Bentall operation (Bentall group, n = 30) or a David operation (David group, n = 29). No operative mortality was recorded. After 20 years (mean follow up 97 ± 82 months; range 1 to 369 months) no prosthesis-related major bleeding or thromboembolic events had been observed; the 20-year survival was 94 ± 6% in the Bentall group, and 100% in the David group (p = 0.32). Freedom from reintervention for aortic valve dysfunction was 100% in the Bentall group, and 75 ± 13% in the David group (p = 0.04). This inter-group difference became relevant after the first eight-year period of follow-up, and was mainly associated with a particular familiar genetic phenotype involving three out of four reoperated patients. Freedom from all-cause death, myocardial infarction, stroke, prosthetic valve-related complications, and reintervention on any aortic segment was 69 ± 12% in the Bentall group, and 67 ± 14% in the David group (p = 0.33). The Bentall and David operations are both associated with satisfactory long-term results in MFS patients. The low rate of valve prosthesis-related complications suggested that the Bentall operation would continue to be a standard surgical treatment. The reimplantation technique, adopted for less-dilated aortas, provides satisfactory freedom from reoperation. Careful attention should be paid to the reimplantation technique in patients affected by a serious familiar genetic phenotype.
Control device for prosthetic urinary sphincter cuff
NASA Technical Reports Server (NTRS)
Reinicke, Robert H. (Inventor)
1983-01-01
A device for controlling flow of fluid to and from a resilient inflatable cuff implanted about the urethra to control flow of urine therethrough. The device comprises a flexible bulb reservoir and a control unit that includes a manually operated valve that opens automatically when the bulb is squeezed to force fluid into the cuff for closing the urethra. The control unit also includes a movable valve seat member having a relatively large area exposed to pressure of fluid in a chamber that is connected to the cuff and which moves to a position in which the valve member is unseated by an abutment when fluid pressure in the chamber exceeds a predetermined value to thereby relieve excess fluid pressure in the cuff. The arrangement is such that the valve element is held closed against the seat member by the full differential in fluid pressures acting on both sides of the valve element until the seat member is moved away from the valve element to thus insure positive closing of the valve element until the seat member is moved out of engagement with the valve element by excess pressure differential.
Rheumatic mitral valve stenosis mimicking advanced lung cancer.
von Lueder, Thomas; Steine, Kjetil; Nerdrum, Tone; Steen, Torkel; Bay, Dag; Humerfelt, Sjur; Atar, Dan
2007-09-01
This report describes a patient with a perihilar mass and mediastinal lymphadenopathy mimicking advanced lung cancer. The patient, a 45-year old regular smoker, was admitted to hospital for dyspnea and tachyarrhythmia, and during hospitalization he was diagnosed with severe rheumatic mitral valve stenosis (MVS) and aortic regurgitation as well as pulmonary venous hypertension. Surgical valve replacement and removal of an atrial thrombus was delayed considerably by diagnostic work-up for suspected malignancy. After cardiac surgery had been performed, recovery was uneventful. On follow-up 1 year later, echocardiography showed well-functioning prosthetic mitral and aortic valves, and normal findings on chest X-ray. Perihilar masses and mediastinal lymphadenopathy presented in this case constitute infrequent yet established findings in MVS, resulting from pulmonary venous congestion and hypertension, and focal lymphedema.
Aggarwal, Sanjeev; Delius, Ralph E; Walters, Henry L; L'Ecuyer, Thomas J
2012-01-01
This case report describes a toddler who developed a protein-losing enteropathy (PLE) 4 years after orthotopic heart transplantation (OHT). He was born with a hypoplastic left heart syndrome for which he underwent a successful Norwood procedure, a Hemi-Fontan palliation, and a Fontan palliation at 18 months of age. Fifteen months following the Fontan operation, he developed a PLE and Fontan failure requiring OHT. Four years after OHT, he developed a severe tricuspid regurgitation and a PLE. His PLE improved after tricuspid valve replacement. It is now 2 years since his tricuspid valve replacement and he remains clinically free of ascites and peripheral edema with a normal serum albumin level. His prosthetic tricuspid valve is functioning normally. © 2011 Wiley Periodicals, Inc.
Analysis of pain and painless symptoms in temporomandibular joints dysfunction in adult patients.
Górecka, Małgorzata; Pihut, Małgorzata; Kulesa-Mrowiecka, Małgorzata
2017-01-01
Recent years have shown an increase in the number of patients reporting for treatment of pain due to musculoskeletal joint, associated with temporomandibular joint dysfunction. Therefore, studies were undertaken, aimed at analyzing the symptoms of the dysfunction, because of which patients come to the prosthetic treatment. Aim of the thesis: The aim of the study was a retrospective analysis of symptoms of temporomandibular joint dysfunction reported by patients diagnosed with this problem. The research material was a retrospective medical records of 120 patients, aged 19 to 45 years who have taken prosthetic treatment due to temporomandibular joint dysfunction in the Consulting Room in Prosthetics Department in Kraków, from June 2015 to December 2016. During the test patients, in addition to interviewing a physician, completed a personal survey in their own study. The material has been divided into I group of patients who reported pain form of dysfunction and II group, who had no symptoms of pain within the stomatognatic system. The analysis covered type of symptoms, the share of local factors (para-functions) and systemic, as well as the time a er which the patients reported for the treatment of functional disorders since the appearance of the first symptoms. Analysis of the research material showed that the main reason for reporting patients was pain in one or both temporal joints of significant intensity (5 to 8 in VAS scale,) accompanied by acoustic symptoms. A large group of questioners reported problems with the range of jaw movement and head and face pain, as well as subjective symptoms from the auditory, sight, neck, neck and shoulder areas.
Fungal Endocarditis Due to Aspergillus oryzae: The First Case Reported in the Literature.
Mazza, Andrea; Luciani, Nicola; Luciani, Marco; Cammertoni, Federico; Giaquinto, Alessia; Pavone, Natalia; Bruno, Piergiorgio; Massetti, Massimo
2017-03-01
Infective endocarditis (IE) is a severe disease with high mortality and morbidity. Prosthetic valve endocarditis is a life-threatening complication which can occur in less than 10% of patients with valve prosthesis. A fungal etiology of IE is rare and accounts for only 2-4% of all case of endocarditis, but is associated with a higher mortality and morbidity. Herein is reported the first case of fungal endocarditis of aortic valve prosthesis due to Aspergillus oryzae in a 67-year-old caucasian man who nine years previously underwent mitral and aortic valve replacement with mechanical prostheses, and tricuspid annuloplasty for acute IE due to Enterococcus spp. Seven months previously, the patient also underwent a redo cardiac procedure to replace a mitral valve prosthesis with a new mechanical device due to a leakage. Aspergillus oryzae showed impressive growth with strong and unexpected virulence in both local and systemic settings.
Wei, Zhenglun Alan; Sonntag, Simon Johannes; Toma, Milan; Singh-Gryzbon, Shelly; Sun, Wei
2018-04-19
The governing international standard for the development of prosthetic heart valves is International Organization for Standardization (ISO) 5840. This standard requires the assessment of the thrombus potential of transcatheter heart valve substitutes using an integrated thrombus evaluation. Besides experimental flow field assessment and ex vivo flow testing, computational fluid dynamics is a critical component of this integrated approach. This position paper is intended to provide and discuss best practices for the setup of a computational model, numerical solving, post-processing, data evaluation and reporting, as it relates to transcatheter heart valve substitutes. This paper is not intended to be a review of current computational technology; instead, it represents the position of the ISO working group consisting of experts from academia and industry with regards to considerations for computational fluid dynamic assessment of transcatheter heart valve substitutes.
Pseudomonas aeruginosa Infective Endocarditis Following Aortic Valve Implantation: A Note of Caution
Dapás, Juan Ignacio; Rivero, Cynthia; Burgos, Pablo; Vila, Andrea
2016-01-01
Transcatheter aortic valve implantation (TAVI) is an alternative treatment for severe aortic valve stenosis (AS) in patients with prohibitive risk for surgical aortic valve replacement (SAVR). Prosthetic valve endocarditis (PVE) is a rare complication of this relatively novel procedure and current guidelines do not include specific recommendations for its treatment. We report a case of PVE due to Pseudomonas aeruginosa after TAVI that required SAVR, with successful outcome. PVE usually occurs during the first year after TAVI and entails a high mortality risk because patients eligible for this min-imally invasive procedure are fragile (i.e. advanced age and/or severe comorbidities). Additionally, clinical presentation may be atypical or subtle and transesophageal echocardiogram (TEE) may not be conclusive, which delays diagnosis and treatment worsening the prognosis. This case highlights that open SAVR might be ultimately indicated as part of treatment for TAVI-PVE despite a high-risk surgery score. PMID:27014375
De Gaetano, Francesco; Serrani, Marta; Bagnoli, Paola; Brubert, Jacob; Stasiak, Joanna; Moggridge, Geoff D.; Costantino, Maria Laura
2016-01-01
Introduction Only mechanical and biological heart valve prostheses are currently commercially available. The former show longer durability but require anticoagulant therapy, the latter display better fluid dynamic behaviour but do not have adequate durability. New Polymeric Heart Valves (PHVs) could potentially combine the haemodynamic properties of biological valves with the durability of mechanical valves. This work presents a hydrodynamic evaluation of two groups of newly developed supra-annular tri-leaflet prosthetic heart valves made from styrenic block copolymers (SBC): Poli-Valves. Methods Two types of Poli-Valves made of SBC differing in polystyrene fraction content were tested under continuous and pulsatile flow conditions as prescribed by ISO 5840 Standard. An ad - hoc designed pulse duplicator allowed the valve prototypes to be tested at different flow rates and frequencies. Pressure and flow were recorded; pressure drops, effective orifice area (EOA), and regurgitant volume were computed to assess the valve’s behaviour. Results Both types Poli-Valves met the minimum requirements in terms of regurgitation and EOA as specified by ISO 5840 Standard. Results were compared with five mechanical heart valves (MHVs) and five tissue heart valves (THVs), currently available on the market. Conclusion Based on these results, polymeric heart valves based on styrenic block copolymers, as Poli-Valves are, can be considered as promising alternative for heart valve replacement in near future. PMID:26689146
De Gaetano, Francesco; Serrani, Marta; Bagnoli, Paola; Brubert, Jacob; Stasiak, Joanna; Moggridge, Geoff D; Costantino, Maria Laura
2015-11-01
Only mechanical and biological heart valve prostheses are currently commercially available. The former show longer durability but require anticoagulant therapy; the latter display better fluid dynamic behavior but do not have adequate durability. New Polymeric Heart Valves (PHVs) could potentially combine the hemodynamic properties of biological valves with the durability of mechanical valves. This work presents a hydrodynamic evaluation of 2 groups of newly developed supra-annular, trileaflet prosthetic heart valves made from styrenic block copolymers (SBC): Poli-Valves. 2 types of Poli-Valves made of SBC and differing in polystyrene fraction content were tested under continuous and pulsatile flow conditions as prescribed by ISO 5840 Standard. A pulse duplicator designed ad hoc allowed the valve prototypes to be tested at different flow rates and frequencies. Pressure and flow were recorded; pressure drops, effective orifice area (EOA), and regurgitant volume were computed to assess the behavior of the valve. Both types of Poli-Valves met the minimum requirements in terms of regurgitation and EOA as specified by the ISO 5840 Standard. Results were compared with 5 mechanical heart valves (MHVs) and 5 tissue heart valves (THVs), currently available on the market. Based on these results, PHVs based on styrenic block copolymers, as are Poli-Valves, can be considered a promising alternative for heart valve replacement in the near future.
Moeinipour, Aliasghar; Zarifian, Ahmadreza; Sheikh Andalibi, Mohammad Sobhan; Shamloo, Alireza Sepehri; Ahmadabadi, Ali; Amouzeshi, Ahmad; Hoseinikhah, Hamid
2015-12-22
It is common practice for patients with prosthetic cardiac devices, especially heart valve prosthesis, arterial stents, defibrillators, and pacemaker devices, to use anticoagulation treatment. When these patients suffer from multiple trauma after motor vehicle accidents, the best medical management for this challenging position is mandatory. This strategy should include a rapid diagnosis of all possible multiple organ injuries, with special attention to anticoagulation therapy so as to minimize the risk of thromboembolism complication in prosthetic devices. In this review, we describe the best medical management for patients with multiple trauma who use anticoagulants after heart valve replacement. We searched electronic databases PubMed/Medline, Scopus, Embase, and Google Scholar using the following terms: anticoagulant, warfarin, heparin, and multiple trauma. Also, similar studies suggested by the databases were included. Non-English articles were excluded from the review. For patients who use anticoagulation therapy, teamwork between cardiac surgeons, general surgeons, anesthesiologists, and cardiologists is essential. For optimal medical management, multiple consults between members of this team is mandatory for rapid diagnosis of all possible damaged organs, with special attention to the central nervous system, chest, and abdominal traumas. With this strategy, it is important to take note of anticoagulation drugs to minimize the risk of thromboembolism complications in cardiac devices. The best anticoagulant agents for emergency operations in patients with multiple trauma who are using an anticoagulant after heart valve replacement are fresh frozen plasma (FFP) and prothrombin complex concentrates (PCC).
[Tricuspid valve insufficiency: what should be done?].
von Segesser, L K; Stauffer, J C; Delabays, A; Chassot, P G
1998-12-01
Tricuspid regurgitation is relatively common. Due to the progress made in echocardiography, its diagnosis is in general made readily and in reliable fashion. Basically one has to distinguish between functional tricuspid valve regurgitation due to volume and/or pressure overload of the right ventricle with intact valve structures versus tricuspid valve regurgitation due to pathologic valve structures. The clear identification of the regurgitation mechanism is of prime importance for the treatment. Functional tricuspid valve regurgitation can often be improved by medical treatment of heart failure, and eventually a tricuspid valve plasty can solve the problem. However, the presence of pathologic tricuspid valve structures makes in general more specific plastic surgical procedures and even prosthetic valve replacements necessary. A typical example for a structural tricuspid valve regurgitation is the case of a traumatic papillary muscle rupture. Due to the sudden onset, this pathology is not well tolerated and requires in general surgical reinsertion of the papillary muscle. In contrast, tricuspid valve regurgitation resulting from chronic pulmonary embolism with pulmonary artery hypertension, can be improved by pulmonary artery thrombendarteriectomy and even completely cured with an additional tricuspid annuloplasty. However, tricuspid regurgitations due to terminal heart failure are not be addressed with surgery directed to tricuspid valve repair or replacement. Heart transplantation, dynamic cardiomyoplasty or mechanical circulatory support should be evaluated instead.
[Minor strut fracture of the Björk-Shiley mitral valve].
Sugita, T; Yasuda, R; Watarida, S; Onoe, M; Tabata, R; Mori, A
1990-06-01
In May, 1982, a 49-year-old man underwent mitral valve replacement (MVR) in our hospital with a 31 mm Björk-Shiley prosthesis for mitral regurgitation. He had been doing well until his episode of palpitation and dyspnea of sudden onset, and was transferred to our ICU with severe cardiogenic shock in Aug, 1986. Chest X-ray film revealed pulmonary edema and breakage of the valve with migration of the disc and the minor strut of the prosthesis. He was operated upon 5 hours after the onset of his complaints. The minor strut was removed from the left upper pulmonary vein and mitral valve re-replacement was done with a 29 mm Björk-Shiley Monostrut valve. The disc which had dislocated into the abdominal aorta was also recovered on the twenty-third post operative day. His postoperative course was uneventful. Immediate diagnosis and subsequent re-operation is absolute indication for rescue from acute cardiac failure due to mechanical failure of any prosthetic valve.
Lalani, Tahaniyat; Chu, Vivian H; Park, Lawrence P; Cecchi, Enrico; Corey, G Ralph; Durante-Mangoni, Emanuele; Fowler, Vance G; Gordon, David; Grossi, Paolo; Hannan, Margaret; Hoen, Bruno; Muñoz, Patricia; Rizk, Hussien; Kanj, Souha S; Selton-Suty, Christine; Sexton, Daniel J; Spelman, Denis; Ravasio, Veronica; Tripodi, Marie Françoise; Wang, Andrew
2013-09-09
There are limited prospective, controlled data evaluating survival in patients receiving early surgery vs medical therapy for prosthetic valve endocarditis (PVE). To determine the in-hospital and 1-year mortality in patients with PVE who undergo valve replacement during index hospitalization compared with patients who receive medical therapy alone, after controlling for survival and treatment selection bias. Participants were enrolled between June 2000 and December 2006 in the International Collaboration on Endocarditis-Prospective Cohort Study (ICE-PCS), a prospective, multinational, observational cohort of patients with infective endocarditis. Patients hospitalized with definite right- or left-sided PVE were included in the analysis. We evaluated the effect of treatment assignment on mortality, after adjusting for biases using a Cox proportional hazards model that included inverse probability of treatment weighting and surgery as a time-dependent covariate. The cohort was stratified by probability (propensity) for surgery, and outcomes were compared between the treatment groups within each stratum. Valve replacement during index hospitalization (early surgery) vs medical therapy. In-hospital and 1-year mortality. Of the 1025 patients with PVE, 490 patients (47.8%) underwent early surgery and 535 individuals (52.2%) received medical therapy alone. Compared with medical therapy, early surgery was associated with lower in-hospital mortality in the unadjusted analysis and after controlling for treatment selection bias (in-hospital mortality: hazard ratio [HR], 0.44 [95% CI, 0.38-0.52] and lower 1-year mortality: HR, 0.57 [95% CI, 0.49-0.67]). The lower mortality associated with surgery did not persist after adjustment for survivor bias (in-hospital mortality: HR, 0.90 [95% CI, 0.76-1.07] and 1-year mortality: HR, 1.04 [95% CI, 0.89-1.23]). Subgroup analysis indicated a lower in-hospital mortality with early surgery in the highest surgical propensity quintile (21.2% vs 37.5%; P = .03). At 1-year follow-up, the reduced mortality with surgery was observed in the fourth (24.8% vs 42.9%; P = .007) and fifth (27.9% vs 50.0%; P = .007) quintiles of surgical propensity. Prosthetic valve endocarditis remains associated with a high 1-year mortality rate. After adjustment for differences in clinical characteristics and survival bias, early valve replacement was not associated with lower mortality compared with medical therapy in the overall cohort. Further studies are needed to define the effect and timing of surgery in patients with PVE who have indications for surgery.
Vrooman, H A; Maliepaard, C; van der Linden, L P; Jessurun, E R; Ludwig, J W; Plokker, H W; Schalij, M J; Weeda, H W; Laufer, J L; Huysmans, H A; Reiber, J H
1997-09-01
The authors developed an analytic software package for the objective and reproducible assessment of a single leg separation (SLS) in the outlet strut of Björk-Shiley convexoconcave (BSCC) prosthetic heart valves. The radiographic cinefilm recordings of 18 phantom valves (12 intact and 6 SLS) and of 43 patient valves were acquired. After digitization of regions of interest in a cineframe, several processing steps were carried out to obtain a one-dimensional corrected and averaged density profile along the central axis of each strut leg. To characterize the degree of possible separation, two quantitative measures were introduced: the normalized pit depth (NPD) and the depth-sigma ratio (DSR). The group of 43 patient studies was divided into a learning set (25 patients) and a test set (18 patients). All phantom valves with an SLS were detected (sensitivity, 100%) at a specificity of 100%. The threshold values for the NPD and the DSR to decide whether a fracture was present or not were 3.6 and 2.5, respectively. On the basis of the visual interpretations of the 25 patient studies (learning set) by an expert panel, it was concluded that none of the patients had an SLS. To achieve a 100% specificity by quantitative analysis, the threshold values for the NPD and the DSR were set at 5.8 and 2.5, respectively, for the patient data. Based on these threshold values, the analysis of patient data from the test set resulted in one false-negative detection and three false-positive detections. An analytic software package for the detection of an SLS was developed. Phantom data showed excellent sensitivity (100%) and specificity (100%). Further research and software development is needed to increase the sensitivity and specificity for patient data.
NASA Astrophysics Data System (ADS)
Liang, Liang; Martin, Caitlin; Wang, Qian; Sun, Wei; Duncan, James
2016-03-01
Aortic valve (AV) disease is a significant cause of morbidity and mortality. The preferred treatment modality for severe AV disease is surgical resection and replacement of the native valve with either a mechanical or tissue prosthetic. In order to develop effective and long-lasting treatment methods, computational analyses, e.g., structural finite element (FE) and computational fluid dynamic simulations, are very effective for studying valve biomechanics. These computational analyses are based on mesh models of the aortic valve, which are usually constructed from 3D CT images though many hours of manual annotation, and therefore an automatic valve shape reconstruction method is desired. In this paper, we present a method for estimating the aortic valve shape from 3D cardiac CT images, which is represented by triangle meshes. We propose a pipeline for aortic valve shape estimation which includes novel algorithms for building local shape dictionaries and for building landmark detectors and curve detectors using local shape dictionaries. The method is evaluated on real patient image dataset using a leave-one-out approach and achieves an average accuracy of 0.69 mm. The work will facilitate automatic patient-specific computational modeling of the aortic valve.
Tsuboko, Yusuke; Shiraishi, Yasuyuki; Yamada, Akihiro; Yambe, Tomoyuki; Matsuo, Satoshi; Saiki, Yoshikatsu; Yamagishi, Masaaki
2015-01-01
Pulmonary conduit valves are used as one of the surgical treatment methods of congenital heart diseases. We have been designing a sophisticated pulmonary conduit valve for the right ventricular outflow tract reconstruction in pediatric patients. In this study, two types of polyester grafts with or without bulging structures for the conduit valves were used and evaluated from the hemodynamic point of view focusing on the application of these conduit valves in the grown-up congenital heart failure patients. We examined valvular function in the originally developed pulmonary mock circulatory system, which consisted of a pneumatic driven right ventricular model, a pulmonary valve chamber, and an elastic pulmonary compliance model with peripheral vascular resistance units. Prior to the measurement, a bileaflet valve was sutured in each conduit. Each conduit valve was installed in the mock right ventricular outflow portion, and its leaflet motion was obtained by using a high-speed camera synchronously with pressure and flow waveforms. As a result, we could obtain hemodynamic changes in two different types of conduits for pulmonary valves, and it was indicated that the presence of the Valsalva shape might be effective for promoting valvular response in the low cardiac output condition.
Jouan, Jérôme; Achouh, Paul; Besson, Laila; Carpentier, Alain; Fabiani, Jean-Noël
2012-09-01
Tricuspid valve surgery in the presence of severe right ventricular dysfunction and pulmonary hypertension secondary to mitral valve stenosis is associated with poor early outcomes. We report the case of a young patient, presenting with severe chronic mitral-tricuspid disease responsible for long-lasting pulmonary hypertension and altered right ventricular function, who initially underwent mitral valve replacement and 7 days later the correction of her tricuspid insufficiency. This 2-staged approach permitted progressive reduction of pulmonary pressure and partial right ventricular remodeling before closing the systolic release valve of the right ventricle represented by tricuspid regurgitation. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Lemke, B; Rathmann, J; Wiebe, V; Witzel, U
1991-08-01
Acute mechanical failure of prosthetic heart valves is rare, but associated with high mortality when occurring. For convexo-concave Björk-Shiley prostheses only fractures of the outlet strut are reported. We present a case of lethal mechanical complication 5 years after implantation. By additional metallurgic analysis we were able to identify a sequential course of the outlet strut fracture. This could lead to new approaches for early detection of this complication.
Ey-Chmielewska, H
1998-01-01
The author presents an attempt of using ultrasonographic technique in diagnosis, planning and observation of treatment results of temporo-mandibular joint pain dysfunctions. Temporo-mandibular joint pain dysfunctions are interchangeably also called temporo-mandibular joint functional disorders. The assessment of pain symptoms in temporo-mandibular joint dysfunctions pain symptoms is principally based on a subjective estimation by the examining practitioner. There is no univocal definition of the disease or a simple index evidencing important symptoms in decision making. Additionally X-ray technique examinations, being hitherto used, in early stages of the disorder do not allow to diagnose it, and are also burdensome to a patient. The aim of this study was to confirm visibility of anatomical elements of the temporo-mandibular joint in an ultrasound examination, assess the mobility of the articular disc before, during and after prosthetic treatment with and without the use of ultrasound technique, and to determine the period of time necessary to obtain a therapeutic effect. The study material consisted of 180 patients, 128 women and 52 men, aged 20 to 60 years, treated by applying prostheses because of temporo-mandibular joint pain dysfunction, in the Department of Prosthetic Dentistry of the Pomeranian Medical Academy. The patients were divided into 2 groups, control and study group. The control group consisted of 90 patients, 63 women and 27 men. In this group prosthetic treatment planning and observation of results was based on a subjective estimation of the practitioner. The study group here comprised 90 patients, 65 women and 25 men, aged 26 to 60 years. In this group prosthetic treatment planning and observation of treatment results were carried on with the use of ultrasound technique. Data from both groups concerning history, results of examinations carried out by ultrasound technique, and the assessment of ultrasound examination were noted on standard examination records used in the Department of Prosthetic Dentistry. For the need of this study an own ultrasound technique was elaborated which allowed for analyzing the ultrasound image in a static situation and during functioning. The ultrasound examination was accomplished with the use of Acuson 128 XP apparatus, linear probe 7.5 MHz. In both groups prosthetic treatment was carried out using different prosthetic methods such as: splints, occlusal adjustment on fixed prosthetic restorations in therapeutical occulus et height in abnormal occlusion. In the study group the therapeutical occulus height was determined under the control of ultrasound technique. Statistical analysis of the obtained results was performed with the use of chi-square test and chi-square test with Yates correction. On the basis of the accomplished study it has been determined that the ultrasound technique makes it possible to visualize morphological elements and facilitates functional observation of the temporo-mandibular joint, articular disc, mandibular condyle and lateral pterygoid muscle in a degree which allows for planning the treatment and the observation of results (Tab. 1-6). The use of ultrasound technique in determining spatial position of the mandible in temporo-mandibular joint permitted to objectively estimate examination results in the study group. A small number of publications on the use of ultrasound technique in functional examination of the temporo-mandibular joint accessible in foreign literature and general reference on the subject in Polish literature do not allow for an objective comparison of obtained study results.
Feder, Stefan; Lehmann, Stefanie; Kullnick, Yvonne; Buschmann, Tilo; Blumert, Conny; Horn, Friedemann; Neuhaus, Jochen; Neujahr, Ralph; Bagaev, Erik; Hagl, Christian; Pichlmaier, Maximilian; Rodloff, Arne Christian; Gräber, Sandra; Kirsch, Katharina; Sandri, Marcus; Kumbhari, Vivek; Behzadi, Armirhossein; Behzadi, Amirali; Correia, Joao Carlos; Mohr, Friedrich Wilhelm
2017-01-01
Aims In infective endocarditis (IE), a severe inflammatory disease of the endocardium with an unchanged incidence and mortality rate over the past decades, only 1% of the cases have been described as polymicrobial infections based on microbiological approaches. The aim of this study was to identify potential biodiversity of bacterial species from infected native and prosthetic valves. Furthermore, we compared the ultrastructural micro-environments to detect the localization and distribution patterns of pathogens in IE. Material and methods Using next-generation sequencing (NGS) of 16S rDNA, which allows analysis of the entire bacterial community within a single sample, we investigated the biodiversity of infectious bacterial species from resected native and prosthetic valves in a clinical cohort of 8 IE patients. Furthermore, we investigated the ultrastructural infected valve micro-environment by focused ion beam scanning electron microscopy (FIB-SEM). Results Biodiversity was detected in 7 of 8 resected heart valves. This comprised 13 bacterial genera and 16 species. In addition to 11 pathogens already described as being IE related, 5 bacterial species were identified as having a novel association. In contrast, valve and blood culture-based diagnosis revealed only 4 species from 3 bacterial genera and did not show any relevant antibiotic resistance. The antibiotics chosen on this basis for treatment, however, did not cover the bacterial spectra identified by our amplicon sequencing analysis in 4 of 8 cases. In addition to intramural distribution patterns of infective bacteria, intracellular localization with evidence of bacterial immune escape mechanisms was identified. Conclusion The high frequency of polymicrobial infections, pathogen diversity, and intracellular persistence of common IE-causing bacteria may provide clues to help explain the persistent and devastating mortality rate observed for IE. Improved bacterial diagnosis by 16S rDNA NGS that increases the ability to tailor antibiotic therapy may result in improved outcomes. PMID:28410379
Minakata, Kenji; Tanaka, Shiro; Tamura, Nobushige; Yanagi, Shigeki; Ohkawa, Yohei; Okonogi, Shuichi; Kaneko, Tatsuo; Usui, Akihiko; Abe, Tomonobu; Shimamoto, Mitsuomi; Takahara, Yoshiharu; Yamanaka, Kazuo; Yaku, Hitoshi; Sakata, Ryuzo
2017-07-25
The aim of this study was to assess the long-term outcomes of aortic valve replacement (AVR) with either mechanical or bioprosthetic valves according to age at operation.Methods and Results:A total of 1,002 patients (527 mechanical valves and 475 bioprosthetic valves) undergoing first-time AVR were categorized according to age at operation: group Y, age <60 years; group M, age 60-69 years; and group O, age ≥70 years). Outcomes were compared on propensity score analysis (adjusted for 28 variables). Hazard ratio (HR) was calculated using the Cox regression model with adjustment for propensity score with bioprosthetic valve as a reference (HR=1). There were no significant differences in overall mortality between mechanical and bioprosthetic valves for all age groups. Valve-related mortality was significantly higher for mechanical valves in group O (HR, 2.53; P=0.02). Reoperation rate was significantly lower for mechanical valves in group Y (HR, 0.16; P<0.01) and group M (no events for mechanical valves). Although the rate of thromboembolic events was higher in mechanical valves in group Y (no events for tissue valves) and group M (HR, 9.05; P=0.03), there were no significant differences in bleeding events between all age groups. The type of prosthetic valve used in AVR does not significantly influence overall mortality.
Tricuspid valve and percutaneous approach: No longer the forgotten valve!
Bouleti, Claire; Juliard, Jean-Michel; Himbert, Dominique; Iung, Bernard; Brochet, Eric; Urena, Marina; Dilly, Marie-Pierre; Ou, Phalla; Nataf, Patrick; Vahanian, Alec
2016-01-01
Tricuspid valve disease is mainly represented by tricuspid regurgitation (TR), which is a predictor of poor outcome. TR is usually secondary, caused by right ventricle pressure or volume overload, the leading cause being left-sided heart valve diseases. Tricuspid surgery for severe TR is recommended during left valve surgery, and consists of either a valve replacement or, most often, a tricuspid repair with or without prosthetic annuloplasty. When TR persists or worsens after left valvular surgery, redo isolated tricuspid surgery is associated with high mortality. In addition, a sizeable proportion of patients present with tricuspid surgery deterioration over time, and need a reintervention, which is associated with high morbi-mortality rates. In this context, and given the recent major breakthrough in the percutaneous treatment of aortic and mitral valve diseases, the tricuspid valve appears an appealing challenge, although it raises specific issues. The first applications of transcatheter techniques for tricuspid valve disease were valve-in-valve and valve-in-ring implantation for degenerated bioprosthesis or ring annuloplasty. Some concerns remain regarding prosthesis sizing, rapid ventricular pacing and the best approach, but these procedures appear to be safe and effective. More recently, bicuspidization using a transcatheter approach for the treatment of native tricuspid valve has been published, in two patients. Finally, other devices are in preclinical development. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
A second prosthesis as a procedural rescue option in trans-apical aortic valve implantation.
Kempfert, Jörg; Rastan, Ardawan J; Schuler, Gerhard; Linke, Axel; Holzhey, David; van Linden, Arnaud; Mohr, Friedrich-W; Walther, Thomas
2011-07-01
Trans-apical aortic valve implantation (TA-AVI) using the Edwards SAPIEN™ prosthesis has evolved to a routine procedure for selected high-risk elderly patients. In rare cases, misplacement of the SAPIEN™ valve (too low a position), dysfunction of the leaflets or perforation of the interventricular septum (ventricular septal defect, VSD) occurs and requires immediate implantation of a second prosthesis within the first one. Results of this 'bailout' maneuver have not been reported yet. Of 305 TA-AVI procedures, 15 patients required a second prosthesis due to dysfunctional leaflets (n = 6), low position (n = 7), or VSD (n = 2). Mean age was 82.5 ± 1.3 years, mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was 45.5 ± 5.4, and Society of Thoracic Surgeons (STS) Score was 13.5 ± 1.5. All second SAPIEN™ valves could be implanted successfully within the first one. The second prosthesis solved leaflet dysfunction, sealed the VSD (lower position of the second prosthesis), or corrected the initial misplacement (higher position of the second prosthesis) in all patients. Within 30 days, four patients died (low cardiac output n = 3, all with preoperative ejection fraction (EF) <35%; intestinal ischemia n = 1). Intra-operative echocardiogram and angiogram revealed mild paravalvular leak in three and none/trace in 12 patients. Transvalvular gradients were low despite the implantation of the second valve (P(max)/mean 13.7 ± 4.3/6.4 ± 2.0). Placement of a second SAPIEN™ valve is a valuable 'bailout' technique in case of VSD, dysfunctional leaflets, or too low placement of the first prosthesis. The technique leads to an excellent functional result with low transvalvular gradients. The simple, straight, tubular stent design of the SAPIEN™ prosthesis may be the ideal design for such valve-in-valve procedures. Copyright © 2011 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Kim, Joon Bum; Ejiofor, Julius I; Yammine, Maroun; Camuso, Janice M; Walsh, Conor W; Ando, Masahiko; Melnitchouk, Serguei I; Rawn, James D; Leacche, Marzia; MacGillivray, Thomas E; Cohn, Lawrence H; Byrne, John G; Sundt, Thoralf M
2016-05-01
Surgical dogma suggests that homografts should be used preferentially, compared with conventional xenograft or mechanical prostheses, in the setting of infective endocarditis (IE), because they have greater resistance to infection. However, comparative data that support this notion are limited. From the prospective databases of 2 tertiary academic centers, we identified 304 consecutive adult patients (age ≥17 years) who underwent surgery for active IE involving the aortic valve (AV), in the period 2002 to 2014. Short- and long-term outcomes were evaluated using propensity scores and inverse-probability weighting to adjust for selection bias. Homografts, and xenograft and mechanical prostheses, were used in 86 (28.3%), 139 (45.7%), and 79 (26.0%) patients, respectively. Homografts were more often used in the setting of prosthetic valve endocarditis (58.1% vs 28.8%, P = .002) and methicillin-resistant Staphylococcus (25.6% vs 12.1%, P = .002), compared with conventional prostheses. Early mortality occurred in 17 (19.8%) in the homograft group, and 20 (9.2%) in the conventional group (P = .019). During follow-up (median: 29.4 months; interquartile-range: 4.7-72.6 months), 60 (19.7%) patients died, and 23 (7.7%) experienced reinfection, with no significant differences in survival (P = .23) or freedom from reinfection rates (P = .65) according to the types of prostheses implanted. After adjustments for baseline characteristics, using propensity-score analyses, use of a homograft did not significantly affect early death (odds ratio 1.61; 95% confidence interval [CI], 0.73-3.40, P = .23), overall death (hazard ratio 1.10; 95% CI, 0.62-1.94, P = .75), or reinfection (hazard ratio 1.04; 95% CI, 0.49-2.18, P = .93). No significant benefit to use of homografts was demonstrable with regard to resistance to reinfection in the setting of IE. The choice among prosthetic options should be based on technical and patient-specific factors. Lack of availability of homografts should not impede appropriate surgical intervention. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Fisher, E A; Estioko, M R; Stern, E H; Goldman, M E
1987-07-01
Aortic root abscess occurs frequently in aortic prosthetic valve infective endocarditis. The present echocardiographic report documents a ruptured abscess that led to a direct communication between the left ventricular outflow tract and the left atrium confirmed by real-time (color flow) Doppler imaging.
A thin film nitinol heart valve.
Stepan, Lenka L; Levi, Daniel S; Carman, Gregory P
2005-11-01
In order to create a less thrombogenic heart valve with improved longevity, a prosthetic heart valve was developed using thin film nitinol (NiTi). A "butterfly" valve was constructed using a single, elliptical piece of thin film NiTi and a scaffold made from Teflon tubing and NiTi wire. Flow tests and pressure readings across the valve were performed in vitro in a pulsatile flow loop. Bio-corrosion experiments were conducted on untreated and passivated thin film nitinol. To determine the material's in vivo biocompatibility, thin film nitinol was implanted in pigs using stents covered with thin film NiTi. Flow rates and pressure tracings across the valve were comparable to those through a commercially available 19 mm Perimount Edwards tissue valve. No signs of corrosion were present on thin film nitinol samples after immersion in Hank's solution for one month. Finally, organ and tissue samples explanted from four pigs at 2, 3, 4, and 6 weeks after thin film NiTi implantation appeared without disease, and the thin film nitinol itself was without thrombus formation. Although long term testing is still necessary, thin film NiTi may be very well suited for use in artificial heart valves.
Park, Byungjoon; Sung, Kiick; Park, Pyo Won
2018-01-25
This study aimed to evaluate the safety and feasibility of transaortic mitral pannus removal (TMPR).Methods and Results:Between 2004 and 2016, 34 patients (median age, 57 years; 30 women) with rheumatic disease underwent pannus removal on the ventricular side of a mechanical mitral valve through the aortic valve during reoperation. The median time interval from the previous surgery was 14 years. TMPR was performed after removal of the mechanical aortic valve (n=21) or diseased native aortic valve (n=11). TMPR was performed in 2 patients through a normal aortic valve. The mitral transprosthetic mean pressure gradient (TMPG) was ≥5 mmHg in 11 patients, including 3 with prosthetic valve malfunction. Prophylactic TMPR was performed in 23 patients. There were no early deaths. Concomitant operations included 22 tricuspid valve surgeries (13 replacements, 15 repairs) and 32 aortic valve replacements (24 repeats, 8 primary). The mean gradient in patients who had mitral TMPG ≥5 mmHg was significantly decreased from 6.46±1.1 to 4.37±1.17 mmHg at discharge (P<0.001). No mechanical valve malfunction was apparent on last echocardiography. TMPR is a safe and effective procedure for patients with malfunction or stenosis of a mechanical mitral valve and may be considered an alternative approach in patients with pannus overgrowth in such valves.
Digital signal processing of the phonocardiogram: review of the most recent advancements.
Durand, L G; Pibarot, P
1995-01-01
The objective of the present paper is to provide a detailed review of the most recent developments in instrumentation and signal processing of digital phonocardiography and heart auscultation. After a short introduction, the paper presents a brief history of heart auscultation and phonocardiography, which is followed by a summary of the basic theories and controversies regarding the genesis of the heart sounds. The application of spectral analysis and the potential of new time-frequency representations and cardiac acoustic mapping to resolve the controversies and better understand the genesis and transmission of heart sounds and murmurs within the heart-thorax acoustic system are reviewed. The most recent developments in the application of linear predictive coding, spectral analysis, time-frequency representation techniques, and pattern recognition for the detection and follow-up of native and prosthetic valve degeneration and dysfunction are also presented in detail. New areas of research and clinical applications and areas of potential future developments are then highlighted. The final section is a discussion about a multidegree of freedom theory on the origin of the heart sounds and murmurs, which is completed by the authors' conclusion.
Design and characterization of a biologically inspired quasi-passive prosthetic ankle-foot.
Mooney, Luke M; Lai, Cara H; Rouse, Elliott J
2014-01-01
By design, commonly worn energy storage and release (ESR) prosthetic feet cannot provide biologically realistic ankle joint torque and angle profiles during walking. Additionally, their anthropomorphic, cantilever architecture causes their mechanical stiffness to decrease throughout the stance phase of walking, opposing the known trend of the biological ankle. In this study, the design of a quasi-passive pneumatic ankle-foot prosthesis is detailed that is able to replicate the biological ankle's torque and angle profiles during walking. The prosthetic ankle is comprised of a pneumatic piston, bending spring and solenoid valve. The mechanical properties of the pneumatic ankle prosthesis are characterized using a materials testing machine and the properties are compared to those from a common, passive ESR prosthetic foot. The characterization spanned a range of ankle equilibrium pressures and testing locations beneath the foot, analogous to the location of center of pressure within the stance phase of walking. The pneumatic ankle prosthesis was shown to provide biologically appropriate trends and magnitudes of torque, angle and stiffness behavior, when compared to the passive ESR prosthetic foot. Future work will focus on the development of a control system for the quasi-passive device and clinical testing of the pneumatic ankle to demonstrate efficacy.
Elective removal of convexo-concave Björk-Shiley valves.
Rajesh, P B; Smith, G H; Lawford, P V; Black, M M
1994-08-01
Replacement has been an accepted method for treating advanced cardiac valvular disease for more than 25 years. However, the perfect prosthesis has yet to be developed, judging by the number of devices available. A prosthesis that initially appears promising may cause problems in due course, and indeed some devices have been modified or withdrawn from clinical use. A notable example of a prosthetic valve that has give problems is the Björk-Shiley convexo-concave prosthesis, some models of which have undergone mechanical failure due to strut fracture. We report the elective removal of such a valve and the subsequent examination of the prosthesis. The results of this examination suggest that a policy of elective removal is justified.
[Tricuspid valve regurgitation : Indications and operative techniques].
Lange, R; Piazza, N; Günther, T
2017-11-01
Functional tricuspid valve (TV) regurgitation secondary to left heart disease (e.g. mitral insufficiency and stenosis) is observed in 75% of the patients with TV regurgitation and is thus the most common etiology; therefore, the majority of patients who require TV surgery, undergo concomitant mitral and/or aortic valve surgery. Uncorrected moderate and severe TV regurgitation may persist or even worsen after mitral valve surgery, leading to progressive heart failure and death. Patients with moderate to severe TV regurgitation show a 3-year survival rate of 40%. Surgery is indicated in patients with severe TV regurgitation undergoing left-sided valve surgery and in patients with severe isolated primary regurgitation without severe right ventricular (RV) dysfunction. For patients requiring mitral valve surgery, tricuspid valve annuloplasty should be considered even in the absence of significant regurgitation, when severe annular dilatation (≥40 mm or >21 mm/m 2 ) is present. Functional TV regurgitation is primarily treated with valve reconstruction which carries a lower perioperative risk than valve replacement. Valve replacement is rarely required. Tricuspid valve repair with ring annuloplasty is associated with better survival and a lower reoperation rate than suture annuloplasty. Long-term results are not available. The severity of the heart insufficiency and comorbidities (e.g. renal failure and liver dysfunction) are the essential determinants of operative mortality and long-term survival. Tricuspid valve reoperations are rarely necessary and associated with a considerable mortality.
Moore, Benjamin; Cao, Jacob; Kotchetkova, Irina; Celermajer, David S
2017-12-15
The prevalence of congenital heart disease (CHD) in the adult population is steadily increasing. A substrate of prosthetic material and residual lesions, constantly evolving as surgical techniques change over time, predispose these patients to the potentially devastating complication of infective endocarditis (IE). We retrospectively reviewed 2935 patients in our adult CHD database for all cases of endocarditis between 1991 and 2016. Incidence, clinical course and predictors of outcomes were analysed. We document 74 episodes in 62 patients, with an incidence of 0.9 cases/1000 patient years (py). IE was more common in complex CHD (1.4 cases/1000py) and ventricular septal defects (VSDs) (1.9 cases/1000py). Prosthetic material was involved in 47% and left-sided infection predominated (66%). The incidence in bicuspid aortic valves post aortic valve replacement (AVR) was significantly higher than in unoperated valves, being 1.8 and 1.1 cases/1000 patient years respectively. Streptococcus was the most frequently implicated causative organism (37%). Emboli occurred in 34% of cases with a cerebral predilection. 46% of patients required surgery during the admission for IE, most frequently to replace a severely regurgitant bicuspid aortic valve. Early endocarditis-related mortality was 15%, associated with cerebral emboli and acute renal failure. In a contemporary adult CHD cohort, those with complex underlying lesions, VSDs or an AVR were at higher risk for IE. Mortality remains substantial and is more likely in patients with cerebral emboli and/or acute renal failure. Copyright © 2017 Elsevier B.V. All rights reserved.
Takamatsu, Masanori; Hirotani, Takashi; Ohtsubo, Satoshi; Saito, Sumikatsu; Takeuchi, Shigeyuki; Hasegawa, Tasuku; Endo, Ayaka; Yamasaki, Yu; Hayashida, Kentaro
2015-06-01
A 67-year-old man on chronic hemodialysis was admitted with worsening congestive heart failure due to critical aortic stenosis. Echocardiography showed severe aortic stenosis with a valve area of 0.67 cm2 and an ejection fraction of 0.31. Cardiac catheterization revealed severe pulmonary hypertension with pulmonary artery pressures of 62/32 mmHg. In the middle of cardiac catheterization, the systolic pressure declined to 60 mmHg due to cardiogenic shock. Dopamine hydrochloride and dobutamine hydrochloride infusions were necessary to maintain a systolic pressure greater than 80 mmHg. Balloon aortic valvuloplasty was urgently performed. The patient's symptoms rapidly resolved except for angina on exertion. One month later, elective aortic valve replacement was performed. The postoperative course was uneventful and the he was discharged on the 60th postoperative day. A follow-up echocardiogram 6 months postoperatively revealed normal prosthetic valve function and an ejection fraction of 0.6.
Fluid-structure interaction in the left ventricle of the human heart coupled with mitral valve
NASA Astrophysics Data System (ADS)
Meschini, Valentina; de Tullio, Marco Donato; Querzoli, Giorgio; Verzicco, Roberto
2016-11-01
In this paper Direct Numerical Simulations (DNS), implemented using a fully fluid-structure interaction model for the left ventricle, the mitral valve and the flowing blood, and laboratory experiments are performed in order to cross validate the results. Moreover a parameter affecting the flow dynamics is the presence of a mitral valve. We model two cases, one with a natural mitral valve and another with a prosthetic mechanical one. Our aim is to understand their different effects on the flow inside the left ventricle in order to better investigate the process of valve replacement. We simulate two situations, one of a healthy left ventricle and another of a failing one. While in the first case the flow reaches the apex of the left ventricle and washout the stagnant fluid with both mechanical and natural valve, in the second case the disturbance generated by the mechanical leaflets destabilizes the mitral jet, thus further decreasing its capability to penetrate the ventricular region and originating heart attack or cardiac pathologies in general.
Sarı, Cenk; Baştuğ, Serdal; Kasapkara, Hacı Ahmet; Durmaz, Tahir; Keleş, Telat; Akçay, Murat; Aslan, Abdullah Nabi; Bayram, Nihal Akar; Bozkurt, Engin
2015-01-01
Introduction Transcatheter aortic valve implantation for severe symptomatic aortic stenosis in patients with a previous mitral valve prosthesis is technically challenging, and pre-procedural comprehensive assessment of these patients before transcatheter aortic valve implantation is vital for an uncomplicated and successful procedure. Aim We want to share our experience with transcatheter aortic valve implantation in patients with a preexisting functional mitral valve prosthesis and describe a series of important technical and pre-procedural details. Material and methods At our center, 135 patients with symptomatic severe aortic stenosis were treated with transcatheter aortic valve implantation. Six of them with a preexisting mitral valve prosthesis received an Edwards SAPIEN XT valve through the transfemoral route. Results Transcatheter aortic valve implantation was performed successfully in all 6 patients without any deformation of the cobalt-chromium/steel stents of the aortic valve bioprosthesis. Also no distortion or malfunction in the mitral valve prosthesis was observed after the procedure. There were no complications during the hospitalization period. Post-procedural echocardiography revealed no or mild aortic paravalvular regurgitation and normal valve function in all the patients. In addition, serial echocardiographic examination demonstrated that both the stability and function of the aortic and mitral prosthetic valves were normal without any deterioration in the gradients and the degree of the regurgitation at long-term follow-ups. Conclusions Our experience confirms that transcatheter aortic valve implantation is technically feasible in patients with previous mitral valve replacement but comprehensive evaluation of patients by multimodal imaging techniques such as transesophageal echocardiography and multislice computed tomography is mandatory for a successful and safe procedure. PMID:26677380
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sochman, Jan; Peregrin, Jan H.; Rocek, Miloslav
Purpose. To evaluate the feasibility of one-step implantation of a new type of stent-based mechanical aortic disc valve prosthesis (MADVP) above and across the native aortic valve and its short-term function in swine with both functional and dysfunctional native valves. Methods. The MADVP consisted of a folding disc valve made of silicone elastomer attached to either a nitinol Z-stent (Z model) or a nitinol cross-braided stent (SX model). Implantation of 10 MADVPs (6 Z and 4 SX models) was attempted in 10 swine: 4 (2 Z and 2 SX models) with a functional native valve and 6 (4 Z andmore » 2 SX models) with aortic regurgitation induced either by intentional valve injury or by MADVP placement across the native valve. MADVP function was observed for up to 3 hr after implantation. Results. MADVP implantation was successful in 9 swine. One animal died of induced massive regurgitation prior to implantation. Four MADVPs implanted above functioning native valves exhibited good function. In 5 swine with regurgitation, MADVP implantation corrected the induced native valve dysfunction and the device's continuous good function was observed in 4 animals. One MADVP (SX model) placed across native valve gradually migrated into the left ventricle. Conclusion. The tested MADVP can be implanted above and across the native valve in a one-step procedure and can replace the function of the regurgitating native valve. Further technical development and testing are warranted, preferably with a manufactured MADVP.« less
Caprari, Patrizia; Tarzia, Anna; Mojoli, Giorgio; Cianciulli, Paolo; Mannella, Emilio; Martorana, Maria Cristina
2009-04-01
The implantation of a prosthetic heart valve (HVP) in patients with hereditary spherocytosis (HS) and hereditary elliptocytosis (HE) is rare, and the changes in the structure and deformability of erythrocytes that follow implantation in these patients have been poorly described. In the present study, the erythrocytes in HS and HE patients with mechanical HVP were compared to the erythrocytes in patients with only congenital membrane defects, in terms of biochemical modifications and rheological behaviour. Integral and cytoskeletal erythrocyte membrane proteins were studied, and blood viscosity (shear rate/shear stress ratio), aggregation ratio [eta(1 s(-1))/eta(200 s(-1))], and red cell visco-elasticity were determined. Valve replacement with a mechanical prosthesis worsened anaemia and resulted in a change in haemolysis, from sub-clinical to evident. The rheological investigation of erythrocytes from HS patients confirmed the characteristic increased viscosity and aggregation ratio and the decreased deformability. The rheological behaviour of erythrocytes from patients with HVP showed a decrease in viscosity and an increase in elastic modulus. In these patients, the prosthesis seems to have induced traumatic damage to the erythrocyte membrane, leading to fragmentation and lysis, which in turn modified rheological parameters. The biochemical and rheological investigation allowed us to understand the clinical and haematological pictures of the patients and to describe the role played by different factors in haemolytic anaemia.
Blot, William J; Ibrahim, Michel A; Ivey, Tom D; Acheson, Donald E; Brookmeyer, Ron; Weyman, Arthur; Defauw, Joseph; Smith, J Kermit; Harrison, Donald
2005-05-31
The first Björk-Shiley convexoconcave (BSCC) prosthetic heart valves were implanted in 1978. The 25th anniversary provided a stimulus to summarize the research data relevant to BSCC valve fracture, patient management, and current clinical options. Published and unpublished data on the risks of BSCC valve fracture and replacement were compiled, and strategies for identifying candidates for prophylactic valve reoperation were summarized. By December 2003, outlet strut fractures (OSFs), often with fatal outcomes, had been reported in 633 BSCC valves (0.7% of 86,000 valves implanted). Fractures still continue to occur, but average rates of OSFs in 60 degrees valves are now <0.1% per year. OSF risk varies markedly by valve characteristics, especially valve angle and size, with weaker effects associated with other manufacturing variables. OSF risks are mildly lower among women than men but decline sharply with advancing age. The risks of valve replacement typically greatly exceed those of OSF. By comparing individualized estimated risks of OSF versus valve replacement, guidelines have been developed to identify the small percentage of BSCC patients (mostly younger men) who would be expected to have a gain in life expectancy should reoperative surgery be performed. Twenty-five years after the initial BSCC valve implants, fractures continue to occur. Continued monitoring of BSCC patients is needed to track and quantify risks and enable periodic updating of guidelines for patients and their physicians.
21 CFR 872.3080 - Mercury and alloy dispenser.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Mercury and alloy dispenser. 872.3080 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3080 Mercury and alloy dispenser. (a) Identification. A mercury and alloy dispenser is a device with a spring-activated valve intended to measure and...
Knox, Karen L; Holmes, Alison H
2002-01-01
The nondiphtheriae corynebacteria are uncommon but increasingly recognized as agents of endocarditis in patients with underlying structural heart disease or prosthetic-valves. We describe three cases of nosocomial endocarditis caused by nondiphtheriae corynebacteria, including the first reported case of Corynebacterium amycolatum, endocarditis. These all occurred in association with indwelling intravascular devices.
21 CFR 872.3080 - Mercury and alloy dispenser.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Mercury and alloy dispenser. 872.3080 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3080 Mercury and alloy dispenser. (a) Identification. A mercury and alloy dispenser is a device with a spring-activated valve intended to measure and...
21 CFR 872.3080 - Mercury and alloy dispenser.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Mercury and alloy dispenser. 872.3080 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3080 Mercury and alloy dispenser. (a) Identification. A mercury and alloy dispenser is a device with a spring-activated valve intended to measure and...
21 CFR 872.3080 - Mercury and alloy dispenser.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Mercury and alloy dispenser. 872.3080 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3080 Mercury and alloy dispenser. (a) Identification. A mercury and alloy dispenser is a device with a spring-activated valve intended to measure and...
Pathophysiologic and Taxonomic Properties of Coagulase-Negative Micrococcaceae.
1983-05-01
implicated as the etiological agents of prosthetic valve endocarditis (Speller and Mitchell, 1973), infections of cerebrospinal fluid shunts (Holt...et al., 1978), peritonitis in patients receiving continuous peritoneal dialysis (Rubin et al., 1980), subacute bacterial endocarditis (Kaye, 1976...tions ( endocarditis , immunocompromised patients, patients with pro- stetic devices and patients with indwelling urinary catheters), one can
18F-FDG-PET/CT Angiography for the Diagnosis of Infective Endocarditis.
Roque, A; Pizzi, M N; Cuéllar-Calàbria, H; Aguadé-Bruix, S
2017-02-01
This article reviews the current imaging role of 18 F-fluordeoxyglucose positron emission computed tomography ( 18 F-FDG-PET/CT) combined with cardiac CT angiography (CTA) in infective endocarditis and discusses the strengths and limitations of this technique. The diagnosis of infective endocarditis affecting prosthetic valves and intracardiac devices is challenging because echocardiography and, therefore, the modified Duke criteria have well-recognized limitations in this clinical scenario. The high sensitivity of 18 F-FDG-PET/CT for the detection of infection associated with the accurate definition of structural damage by gated cardiac CTA in a combined technique (PET/CTA) has provided a significant increase in diagnostic sensitivity for the detection of IE. PET/CTA has proven to be a useful diagnostic tool in patients with suspected infective endocarditis. The additional information provided by this technique improves diagnostic performance in prosthetic valve endocarditis when it is used in combination with the Duke criteria. The findings obtained in PET/CTA studies have been included as a major criterion in the recently updated diagnostic algorithm in infective endocarditis guidelines.
Diagnostic value of imaging in infective endocarditis: a systematic review.
Gomes, Anna; Glaudemans, Andor W J M; Touw, Daan J; van Melle, Joost P; Willems, Tineke P; Maass, Alexander H; Natour, Ehsan; Prakken, Niek H J; Borra, Ronald J H; van Geel, Peter Paul; Slart, Riemer H J A; van Assen, Sander; Sinha, Bhanu
2017-01-01
Sensitivity and specificity of the modified Duke criteria for native valve endocarditis are both suboptimal, at approximately 80%. Diagnostic accuracy for intracardiac prosthetic material-related infection is even lower. Non-invasive imaging modalities could potentially improve diagnosis of infective endocarditis; however, their diagnostic value is unclear. We did a systematic literature review to critically appraise the evidence for the diagnostic performance of these imaging modalities, according to PRISMA and GRADE criteria. We searched PubMed, Embase, and Cochrane databases. 31 studies were included that presented original data on the performance of electrocardiogram (ECG)-gated multidetector CT angiography (MDCTA), ECG-gated MRI, 18 F-fluorodeoxyglucose ( 18 F-FDG) PET/CT, and leucocyte scintigraphy in diagnosis of native valve endocarditis, intracardiac prosthetic material-related infection, and extracardiac foci in adults. We consistently found positive albeit weak evidence for the diagnostic benefit of 18 F-FDG PET/CT and MDCTA. We conclude that additional imaging techniques should be considered if infective endocarditis is suspected. We propose an evidence-based diagnostic work-up for infective endocarditis including these non-invasive techniques. Copyright © 2017 Elsevier Ltd. All rights reserved.
Indications for cardiac surgery in patients with active infective endocarditis.
Alsip, S G; Blackstone, E H; Kirklin, J W; Cobbs, C G
1985-06-28
Currently, absolute indications for valve replacement during active infective endocarditis include severe heart failure, the presence of an infecting microorganism that is not susceptible to available antimicrobial agents, and, in patients with an infected prosthetic valve, an unstable device. Relative indications include an etiologic microorganism other than a susceptible Streptococcus, relapse after presumed effective therapy, evidence of intracardiac extension of the infection, two or more systemic emboli, vegetations large enough to be demonstrated by echocardiography, and, in patients with an infected prosthetic device, early disease and periprosthetic leak. With use of data from the medical literature, a study generated by the cardiovascular surgical group at the University of Alabama School of Medicine, and a brief cost analysis, a point system was constructed to assist in decision-making concerning surgery in patients with active infective endocarditis. The usefulness of this system will depend on experience generated from its utilization in a larger number of patients as well as new data relative to a more complete understanding of the risks and benefits of surgery in this condition.
Pathology of myxomatous mitral valve disease in the dog.
Fox, Philip R
2012-03-01
Mitral valve competence requires complex interplay between structures that comprise the mitral apparatus - the mitral annulus, mitral valve leaflets, chordae tendineae, papillary muscles, and left atrial and left ventricular myocardium. Myxomatous mitral valve degeneration is prevalent in the canine, and most adult dogs develop some degree of mitral valve disease as they age, highlighting the apparent vulnerability of canine heart valves to injury. Myxomatous valvular remodeling is associated with characteristic histopathologic features. Changes include expansion of extracellular matrix with glycosaminoglycans and proteoglycans; valvular interstitial cell alteration; and attenuation or loss of the collagen-laden fibrosa layer. These lead to malformation of the mitral apparatus, biomechanical dysfunction, and mitral incompetence. Mitral regurgitation is the most common manifestation of myxomatous valve disease and in advanced stages, associated volume overload promotes progressive valvular regurgitation, left atrial and left ventricular remodeling, atrial tears, chordal rupture, and congestive heart failure. Future studies are necessary to identify clinical-pathologic correlates that track disease severity and progression, detect valve dysfunction, and facilitate risk stratification. It remains unresolved whether, or to what extent, the pathobiology of myxomatous mitral valve degeneration is the same between breeds of dogs, between canines and humans, and how these features are related to aging and genetics. Copyright © 2012 Elsevier B.V. All rights reserved.
Durability of Aortic Valve Cusp Repair With and Without Annular Support.
Zeeshan, Ahmad; Idrees, Jay J; Johnston, Douglas R; Rajeswaran, Jeevanantham; Roselli, Eric E; Soltesz, Edward G; Gillinov, A Marc; Griffin, Brian; Grimm, Richard; Hammer, Donald F; Pettersson, Gösta B; Blackstone, Eugene H; Sabik, Joseph F; Svensson, Lars G
2018-03-01
To determine the value of aortic valve repair rather than replacement for valve dysfunction, we assessed late outcomes of various repair techniques in the contemporary era. From January 2001 to January 2011, aortic valve repair was planned in 1,124 patients. Techniques involved commissural figure-of-8 suspension sutures (n = 63 [6.2%]), cusp repair with commissuroplasty (n = 481 [48%]), debridement (n = 174 [17%]), free-margin plication (n = 271 [27%]) or resection (n = 75) or both, or annulus repair with resuspension (n = 230 [23%]), root reimplantation (n = 252 [25%]), or remodeling (n = 35 [3.5%]). Planned repair was aborted for replacement in 115 patients (10%); risk factors included greater severity of aortic regurgitation (AR; p = 0.0002) and valve calcification (p < 0.0001). In-hospital outcomes for the remaining 1,009 patients included death (12 [1.2%]), stroke (13 [1.3%]), and reoperation for valve dysfunction (14 [1.4%]). Freedom from aortic valve reoperation at 1, 5, and 10 years was 97%, 93%, and 90%, respectively. Figure-of-8 suspension sutures, valve resuspension, and root repair and replacement were least likely to require reoperation; cusp repair with commissural sutures, plication, and commissuroplasty was most likely (p < 0.05). Survival at 1, 5, and 10 years was 96%, 92%, and 83%. Immediate postoperative AR grade was none-mild (94%), moderate (5%), and severe (1%). At 10 years after repair, AR grade was none (20%), mild (33%), moderate (26%), and severe (21%). Patients undergoing root procedures were less likely to have higher-grade postoperative AR (p < 0.0001). Valve repair is effective and durable for treating aortic valve dysfunction. Greater severity of AR preoperatively is associated with higher likelihood of repair failure. Commissural figure-of-8 suspension sutures and repair with annular support have the best long-term durability. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
McElhinney, Doff B.; Hellenbrand, William E.; Zahn, Evan M.; Jones, Thomas K.; Cheatham, John P.; Lock, James E.; Vincent, Julie A.
2014-01-01
Background Transcatheter pulmonary valve placement is an emerging therapy for pulmonary regurgitation and right ventricular outflow tract obstruction in selected patients. The Melody valve was recently approved in the United States for placement in dysfunctional right ventricular outflow tract conduits. Methods and Results From January 2007 to August 2009, 136 patients (median age, 19 years) underwent catheterization for intended Melody valve implantation at 5 centers. Implantation was attempted in 124 patients; in the other 12, transcatheter pulmonary valve placement was not attempted because of the risk of coronary artery compression (n=6) or other clinical or protocol contraindications. There was 1 death from intracranial hemorrhage after coronary artery dissection, and 1 valve was explanted after conduit rupture. The median peak right ventricular outflow tract gradient was 37 mm Hg before implantation and 12 mm Hg immediately after implantation. Before implantation, pulmonary regurgitation was moderate or severe in 92 patients (81% with data); no patient had more than mild pulmonary regurgitation early after implantation or during follow-up (≥1 year in 65 patients). Freedom from diagnosis of stent fracture was 77.8±4.3% at 14 months. Freedom from Melody valve dysfunction or reintervention was 93.5±2.4% at 1 year. A higher right ventricular outflow tract gradient at discharge (P=0.003) and younger age (P=0.01) were associated with shorter freedom from dysfunction. Conclusions In this updated report from the multicenter US Melody valve trial, we demonstrated an ongoing high rate of procedural success and encouraging short-term valve function. All reinterventions in this series were for right ventricular outflow tract obstruction, highlighting the importance of patient selection, adequate relief of obstruction, and measures to prevent and manage stent fracture. Clinical Trial Registration URL: http://www.clinicaltrials.gov. Unique identifier: NCT00740870. PMID:20644013
NASA Astrophysics Data System (ADS)
Fix, Brandon R.; Popma, Christopher J.; Bulusu, Kartik V.; Plesniak, Michael W.
2013-11-01
Each year, hundreds of thousands of aortic and mitral heart valves are replaced with prosthetic valves. In efforts to develop a valve that does not require lifelong anticoagulation therapy, previous experimental research has been devoted to analyzing the hemodynamics of various heart valve designs, limited to the flow up to only 2 diameters downstream of the valve. Two-component, two-dimensional (2C-2D) particle image velocimetry (PIV) was used in this study to examine secondary flow velocity fields in a curved tube modeling an aorta at five locations (0-, 45-, 90-, 135-, 180-degrees). A bileaflet valve, opened to 30-, 45-, and 59-degrees, and one (no-valve) baseline condition were examined under three steady flow inflows (Re = 218, 429, 634). In particular, variations in the two-dimensional turbulent shear stresses at each cross sectional plane were analyzed. The results suggest that bileaflet valves in the aortic model produce significant turbulence and vorticity up to 5.5 downstream diameters, i.e. up to the 90-degrees location. Expanding this research towards aortic heart valve hemodynamics highlights a need for additional studies extending beyond the typical few diameters downstream to fully characterize valvular function. Supported by the NSF Grant No. CBET- 0828903 and GW Center for Biomimetics and Bioinspired Engineering.
Semkin, V A; Rabukhina, N A; Kravchenko, D V
2007-01-01
Patients with temporo-mandibular joint (TMJ) dysfunction need complex treatment that includes prosthetic treatment in intrajoint relation stabilization. In cases of TMJ pathology it is necessary to examine patients and make axiography, function analysis, MPI-analysis, magnetic resonance tomography and zonography of TMJ, electromyography of the masticatory muscles. The authors examined 47 patients with TMJ dysfunction, 43 of them had occlusion pathology. We managed to eliminate the dysfunction symptoms and to receive stable result of the treatment in all the patients.
Tomographic PIV behind a prosthetic heart valve
NASA Astrophysics Data System (ADS)
Hasler, D.; Landolt, A.; Obrist, D.
2016-05-01
The instantaneous three-dimensional velocity field past a bioprosthetic heart valve was measured using tomographic particle image velocimetry. Two digital cameras were used together with a mirror setup to record PIV images from four different angles. Measurements were conducted in a transparent silicone phantom with a simplified geometry of the aortic root. The refraction indices of the silicone phantom and the working fluid were matched to minimize optical distortion from the flow field to the cameras. The silicone phantom of the aorta was integrated in a flow loop driven by a piston pump. Measurements were conducted for steady and pulsatile flow conditions. Results of the instantaneous, ensemble and phase-averaged flow field are presented. The three-dimensional velocity field reveals a flow topology, which can be related to features of the aortic valve prosthesis.
Curved butterfly bileaflet prosthetic cardiac valve
McQueen, David M.; Peskin, Charles S.
1991-06-25
An annular valve body having a central passageway for the flow of blood therethrough with two curved leaflets each of which is pivotally supported on an accentric positioned axis in the central passageway for moving between a closed position and an open position. The leaflets are curved in a plane normal to the eccentric axis and positioned with the convex side of the leaflets facing each other when the leaflets are in the open position. Various parameters such as the curvature of the leaflets, the location of the eccentric axis, and the maximum opening angle of the leaflets are optimized according to the following performance criteria: maximize the minimum peak velocity through the valve, maximize the net stroke volume, and minimize the mean forward pressure difference, thereby reducing thrombosis and improving the hemodynamic performance.
Current progress in tissue engineering of heart valves: multiscale problems, multiscale solutions.
Cheung, Daniel Y; Duan, Bin; Butcher, Jonathan T
2015-01-01
Heart valve disease is an increasingly prevalent and clinically serious condition. There are no clinically effective biological diagnostics or treatment strategies. The only recourse available is replacement with a prosthetic valve, but the inability of these devices to grow or respond biologically to their environments necessitates multiple resizing surgeries and life-long coagulation treatment, especially in children. Tissue engineering has a unique opportunity to impact heart valve disease by providing a living valve conduit, capable of growth and biological integration. This review will cover current tissue engineering strategies in fabricating heart valves and their progress towards the clinic, including molded scaffolds using naturally derived or synthetic polymers, decellularization, electrospinning, 3D bioprinting, hybrid techniques, and in vivo engineering. Whereas much progress has been made to create functional living heart valves, a clinically viable product is not yet realized. The next leap in engineered living heart valves will require a deeper understanding of how the natural multi-scale structural and biological heterogeneity of the tissue ensures its efficient function. Related, improved fabrication strategies must be developed that can replicate this de novo complexity, which is likely instructive for appropriate cell differentiation and remodeling whether seeded with autologous stem cells in vitro or endogenously recruited cells.
Current Progress in Tissue Engineering of Heart Valves: Multiscale Problems, Multiscale Solutions
Cheung, Daniel Y; Duan, Bin; Butcher, Jonathan T.
2016-01-01
Introduction Heart valve disease is an increasingly prevalent and clinically serious condition. There are no clinically effective biological diagnostics or treatment strategies. The only recourse available is replacement with a prosthetic valve, but the inability of these devices to grow or respond biologically to their environments necessitates multiple resizing surgeries and life-long coagulation treatment, especially in children. Tissue engineering has a unique opportunity to impact heart valve disease by providing a living valve conduit, capable of growth and biological integration. Areas covered This review will cover current tissue engineering strategies in fabricating heart valves and their progress towards the clinic, including molded scaffolds using naturally-derived or synthetic polymers, decellularization, electrospinning, 3D bioprinting, hybrid techniques, and in vivo engineering. Expert opinion While much progress has been made to create functional living heart valves, a clinically viable product is not yet realized. The next leap in engineered living heart valves will require a deeper understanding of how the natural multi-scale structural and biological heterogeneity of the tissue ensures its efficient function. Related, improved fabrication strategies must be developed that can replicate this de novo complexity, which is likely instructive for appropriate cell differentiation and remodeling whether seeded with autologous stem cells in vitro or endogenously recruited cells. PMID:26027436
Impact of routine cerebral CT angiography on treatment decisions in infective endocarditis.
Meshaal, Marwa Sayed; Kassem, Hussein Heshmat; Samir, Ahmad; Zakaria, Ayman; Baghdady, Yasser; Rizk, Hussein Hassan
2015-01-01
Infective endocarditis (IE) is commonly complicated by cerebral embolization and hemorrhage secondary to intracranial mycotic aneurysms (ICMAs). These complications are associated with poor outcome and may require diagnostic and therapeutic plans to be modified. However, routine screening by brain CT and CT angiography (CTA) is not standard practice. We aimed to study the impact of routine cerebral CTA on treatment decisions for patients with IE. From July 2007 to December 2012, we prospectively recruited 81 consecutive patients with definite left-sided IE according to modified Duke's criteria. All patients had routine brain CTA conducted within one week of admission. All patients with ICMA underwent four-vessel conventional angiography. Invasive treatment was performed for ruptured aneurysms, aneurysms ≥ 5 mm, and persistent aneurysms despite appropriate therapy. Surgical clipping was performed for leaking aneurysms if not amenable to intervention. The mean age was 30.43 ± 8.8 years and 60.5% were males. Staph aureus was the most common organism (32.3%). Among the patients, 37% had underlying rheumatic heart disease, 26% had prosthetic valves, 23.5% developed IE on top of a structurally normal heart and 8.6% had underlying congenital heart disease. Brain CT/CTA revealed that 51 patients had evidence of cerebral embolization, of them 17 were clinically silent. Twenty-six patients (32%) had ICMA, of whom 15 were clinically silent. Among the patients with ICMAs, 11 underwent endovascular treatment and 2 underwent neurovascular surgery. The brain CTA findings prompted different treatment choices in 21 patients (25.6%). The choices were aneurysm treatment before cardiac surgery rather than at follow-up, valve replacement by biological valve instead of mechanical valve, and withholding anticoagulation in patients with prosthetic valve endocarditis for fear of aneurysm rupture. Routine brain CT/CTA resulted in changes in the treatment plan in a significant proportion of patients with IE, even those without clinically evident neurological disease. Routine brain CT/CTA may be indicated in all hospitalized patients with IE.
Chirouze, Catherine; Alla, François; Fowler, Vance G; Sexton, Daniel J; Corey, G Ralph; Chu, Vivian H; Wang, Andrew; Erpelding, Marie-Line; Durante-Mangoni, Emanuele; Fernández-Hidalgo, Nuria; Giannitsioti, Efthymia; Hannan, Margaret M; Lejko-Zupanc, Tatjana; Miró, José M; Muñoz, Patricia; Murdoch, David R; Tattevin, Pierre; Tribouilloy, Christophe; Hoen, Bruno
2015-03-01
The impact of early valve surgery (EVS) on the outcome of Staphylococcus aureus (SA) prosthetic valve infective endocarditis (PVIE) is unresolved. The objective of this study was to evaluate the association between EVS, performed within the first 60 days of hospitalization, and outcome of SA PVIE within the International Collaboration on Endocarditis-Prospective Cohort Study. Participants were enrolled between June 2000 and December 2006. Cox proportional hazards modeling that included surgery as a time-dependent covariate and propensity adjustment for likelihood to receive cardiac surgery was used to evaluate the impact of EVS and 1-year all-cause mortality on patients with definite left-sided S. aureus PVIE and no history of injection drug use. EVS was performed in 74 of the 168 (44.3%) patients. One-year mortality was significantly higher among patients with S. aureus PVIE than in patients with non-S. aureus PVIE (48.2% vs 32.9%; P = .003). Staphylococcus aureus PVIE patients who underwent EVS had a significantly lower 1-year mortality rate (33.8% vs 59.1%; P = .001). In multivariate, propensity-adjusted models, EVS was not associated with 1-year mortality (risk ratio, 0.67 [95% confidence interval, .39-1.15]; P = .15). In this prospective, multinational cohort of patients with S. aureus PVIE, EVS was not associated with reduced 1-year mortality. The decision to pursue EVS should be individualized for each patient, based upon infection-specific characteristics rather than solely upon the microbiology of the infection causing PVIE. © The Author 2014. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Chirouze, Catherine; Alla, François; Fowler, Vance G.; Sexton, Daniel J.; Corey, G. Ralph; Chu, Vivian H.; Wang, Andrew; Erpelding, Marie-Line; Durante-Mangoni, Emanuele; Fernández-Hidalgo, Nuria; Giannitsioti, Efthymia; Hannan, Margaret M.; Lejko-Zupanc, Tatjana; Miró, José M.; Muñoz, Patricia; Murdoch, David R.; Tattevin, Pierre; Tribouilloy, Christophe; Hoen, Bruno; Clara, Liliana; Sanchez, Marisa; Nacinovich, Francisco; Oses, Pablo Fernandez; Ronderos, Ricardo; Sucari, Adriana; Thierer, Jorge; Casabé, José; Cortes, Claudia; Altclas, Javier; Kogan, Silvia; Spelman, Denis; Athan, Eugene; Harris, Owen; Kennedy, Karina; Tan, Ren; Gordon, David; Papanicolas, Lito; Eisen, Damon; Grigg, Leeanne; Street, Alan; Korman, Tony; Kotsanas, Despina; Dever, Robyn; Jones, Phillip; Konecny, Pam; Lawrence, Richard; Rees, David; Ryan, Suzanne; Feneley, Michael P.; Harkness, John; Jones, Phillip; Ryan, Suzanne; Jones, Phillip; Ryan, Suzanne; Jones, Phillip; Post, Jeffrey; Reinbott, Porl; Ryan, Suzanne; Gattringer, Rainer; Wiesbauer, Franz; Andrade, Adriana Ribas; de Brito, Ana Cláudia Passos; Guimarães, Armenio Costa; Grinberg, Max; Mansur, Alfredo José; Siciliano, Rinaldo Focaccia; Strabelli, Tania Mara Varejao; Vieira, Marcelo Luiz Campos; de Medeiros Tranchesi, Regina Aparecida; Paiva, Marcelo Goulart; Fortes, Claudio Querido; de Oliveira Ramos, Auristela; Ferraiuoli, Giovanna; Golebiovski, Wilma; Lamas, Cristiane; Santos, Marisa; Weksler, Clara; Karlowsky, James A.; Keynan, Yoav; Morris, Andrew M.; Rubinstein, Ethan; Jones, Sandra Braun; Garcia, Patricia; Cereceda, M; Fica, Alberto; Mella, Rodrigo Montagna; Barsic, Bruno; Bukovski, Suzana; Krajinovic, Vladimir; Pangercic, Ana; Rudez, Igor; Vincelj, Josip; Freiberger, Tomas; Pol, Jiri; Zaloudikova, Barbora; Ashour, Zainab; El Kholy, Amani; Mishaal, Marwa; Rizk, Hussien; Aissa, Neijla; Alauzet, Corentine; Alla, Francois; Campagnac, Catherine; Doco-Lecompte, Thanh; Selton-Suty, Christine; Casalta, Jean-Paul; Fournier, Pierre-Edouard; Habib, Gilbert; Raoult, Didier; Thuny, Franck; Delahaye, François; Delahaye, Armelle; Vandenesch, Francois; Donal, Erwan; Donnio, Pierre Yves; Michelet, Christian; Revest, Matthieu; Tattevin, Pierre; Violette, Jérémie; Chevalier, Florent; Jeu, Antoine; Sorel, Claire; Tribouilloy, Christophe; Bernard, Yvette; Chirouze, Catherine; Hoen, Bruno; Leroy, Joel; Plesiat, Patrick; Naber, Christoph; Neuerburg, Carl; Mazaheri, Bahram; Naber, Christoph; Neuerburg, Carl; Athanasia, Sofia; Giannitsioti, Efthymia; Mylona, Elena; Paniara, Olga; Papanicolaou, Konstantinos; Pyros, John; Skoutelis, Athanasios; Sharma, Gautam; Francis, Johnson; Nair, Lathi; Thomas, Vinod; Venugopal, Krishnan; Hannan, Margaret; Hurley, John; Gilon, Dan; Israel, Sarah; Korem, Maya; Strahilevitz, Jacob; Rubinstein, Ethan; Strahilevitz, Jacob; Casillo, Roberta; Cuccurullo, Susanna; Dialetto, Giovanni; Durante-Mangoni, Emanuele; Irene, Mattucci; Ragone, Enrico; Tripodi, Marie Françoise; Utili, Riccardo; Cecchi, Enrico; De Rosa, Francesco; Forno, Davide; Imazio, Massimo; Trinchero, Rita; Tebini, Alessandro; Grossi, Paolo; Lattanzio, Mariangela; Toniolo, Antonio; Goglio, Antonio; Raglio, Annibale; Ravasio, Veronica; Rizzi, Marco; Suter, Fredy; Carosi, Giampiero; Magri, Silvia; Signorini, Liana; Baban, Tania; Kanafani, Zeina; Kanj, Souha S.; Yasmine, Mohamad; Abidin, Imran; Tamin, Syahidah Syed; Martínez, Eduardo Rivera; Soto Nieto, Gabriel Israel; van der Meer, Jan T.M.; Chambers, Stephen; Holland, David; Morris, Arthur; Raymond, Nigel; Read, Kerry; Murdoch, David R.; Dragulescu, Stefan; Ionac, Adina; Mornos, Cristian; Butkevich, O.M.; Chipigina, Natalia; Kirill, Ozerecky; Vadim, Kulichenko; Vinogradova, Tatiana; Edathodu, Jameela; Halim, Magid; Lum, Luh-Nah; Tan, Ru-San; Lejko-Zupanc, Tatjana; Logar, Mateja; Mueller-Premru, Manica; Commerford, Patrick; Commerford, Anita; Deetlefs, Eduan; Hansa, Cass; Ntsekhe, Mpiko; Almela, Manuel; Armero, Yolanda; Azqueta, Manuel; Castañeda, Ximena; Cervera, Carlos; del Rio, Ana; Falces, Carlos; Garcia-de-la-Maria, Cristina; Fita, Guillermina; Gatell, Jose M.; Marco, Francesc; Mestres, Carlos A.; Miró, José M.; Moreno, Asuncion; Ninot, Salvador; Paré, Carlos; Pericas, Joan; Ramirez, Jose; Rovira, Irene; Sitges, Marta; Anguera, Ignasi; Font, Bernat; Guma, Joan Raimon; Bermejo, Javier; Bouza, Emilio; Fernández, Miguel Angel Garcia; Gonzalez-Ramallo, Victor; Marín, Mercedes; Muñoz, Patricia; Pedromingo, Miguel; Roda, Jorge; Rodríguez-Créixems, Marta; Solis, Jorge; Almirante, Benito; Fernandez-Hidalgo, Nuria; Tornos, Pilar; de Alarcón, Arístides; Parra, Ricardo; Alestig, Eric; Johansson, Magnus; Olaison, Lars; Snygg-Martin, Ulrika; Pachirat, Orathai; Pachirat, Pimchitra; Pussadhamma, Burabha; Senthong, Vichai; Casey, Anna; Elliott, Tom; Lambert, Peter; Watkin, Richard; Eyton, Christina; Klein, John L.; Bradley, Suzanne; Kauffman, Carol; Bedimo, Roger; Chu, Vivian H.; Corey, G. Ralph; Crowley, Anna Lisa; Douglas, Pamela; Drew, Laura; Fowler, Vance G.; Holland, Thomas; Lalani, Tahaniyat; Mudrick, Daniel; Samad, Zaniab; Sexton, Daniel; Stryjewski, Martin; Wang, Andrew; Woods, Christopher W.; Lerakis, Stamatios; Cantey, Robert; Steed, Lisa; Wray, Dannah; Dickerman, Stuart A.; Bonilla, Hector; DiPersio, Joseph; Salstrom, Sara-Jane; Baddley, John; Patel, Mukesh; Peterson, Gail; Stancoven, Amy; Afonso, Luis; Kulman, Theresa; Levine, Donald; Rybak, Michael; Cabell, Christopher H.; Baloch, Khaula; Chu, Vivian H.; Corey, G. Ralph; Dixon, Christy C.; Fowler, Vance G.; Harding, Tina; Jones-Richmond, Marian; Pappas, Paul; Park, Lawrence P.; Redick, Thomas; Stafford, Judy; Anstrom, Kevin; Athan, Eugene; Bayer, Arnold S.; Cabell, Christopher H.; Chu, Vivian H.; Corey, G. Ralph; Fowler, Vance G.; Hoen, Bruno; Karchmer, A. W.; Miró, José M.; Murdoch, David R.; Sexton, Daniel J.; Wang, Andrew; Bayer, Arnold S.; Cabell, Christopher H.; Chu, Vivian; Corey, G. Ralph; Durack, David T.; Eykyn, Susannah; Fowler, Vance G.; Hoen, Bruno; Miró, José M.; Moreillon, Phillipe; Olaison, Lars; Raoult, Didier; Rubinstein, Ethan; Sexton, Daniel J.
2015-01-01
Background. The impact of early valve surgery (EVS) on the outcome of Staphylococcus aureus (SA) prosthetic valve infective endocarditis (PVIE) is unresolved. The objective of this study was to evaluate the association between EVS, performed within the first 60 days of hospitalization, and outcome of SA PVIE within the International Collaboration on Endocarditis–Prospective Cohort Study. Methods. Participants were enrolled between June 2000 and December 2006. Cox proportional hazards modeling that included surgery as a time-dependent covariate and propensity adjustment for likelihood to receive cardiac surgery was used to evaluate the impact of EVS and 1-year all-cause mortality on patients with definite left-sided S. aureus PVIE and no history of injection drug use. Results. EVS was performed in 74 of the 168 (44.3%) patients. One-year mortality was significantly higher among patients with S. aureus PVIE than in patients with non–S. aureus PVIE (48.2% vs 32.9%; P = .003). Staphylococcus aureus PVIE patients who underwent EVS had a significantly lower 1-year mortality rate (33.8% vs 59.1%; P = .001). In multivariate, propensity-adjusted models, EVS was not associated with 1-year mortality (risk ratio, 0.67 [95% confidence interval, .39–1.15]; P = .15). Conclusions. In this prospective, multinational cohort of patients with S. aureus PVIE, EVS was not associated with reduced 1-year mortality. The decision to pursue EVS should be individualized for each patient, based upon infection-specific characteristics rather than solely upon the microbiology of the infection causing PVIE. PMID:25389255
Endocarditis caused by anaerobic bacteria.
Kestler, M; Muñoz, P; Marín, M; Goenaga, M A; Idígoras Viedma, P; de Alarcón, A; Lepe, J A; Sousa Regueiro, D; Bravo-Ferrer, J M; Pajarón, M; Costas, C; García-López, M V; Hidalgo-Tenorio, C; Moreno, M; Bouza, E
2017-10-01
Infective endocarditis (IE) caused by anaerobic bacteria is a rare and poorly characterized disease. Most data reported in the literature are from case reports [1-3]. Therefore, we assessed the situation of anaerobic IE (AIE) in Spain using the database of the Spanish Collaboration on Endocarditis (GAMES). We performed a prospective study from 2008 to 2016 in 26 Spanish centers. We included 2491 consecutive cases of definite IE (Duke criteria). Anaerobic bacteria caused 22 cases (0.9%) of definite IE. Median age was 66 years (IQR, 56-73), and 19 (86.4%) patients were men. Most patients (14 [63.6%]) had prosthetic valve IE and all episodes were left-sided: aortic valves, 12 (54.5%); and mitral valves, 8 (36.4%). The most common pathogens were Propionibacterium acnes (14 [63.6%]), Lactobacillus spp (3 [13.63%]), and Clostridium spp. (2 [9.0%]), and the infection was mainly odontogenic. Fifteen of the 22 patients (68.2%) underwent cardiac surgery. Mortality was 18.2% during admission and 5.5% after 1 year of follow-up. When patients with AIE were compared with the rest of the cohort, we found that although those with AIE had a similar age and Charlson comorbidity index, they were more likely to have community-acquired IE (86.4% vs. 60.9%, p = 0.01), have undergone cardiac surgery (68.2% vs 48.7% p = 0.06), and have had lower mortality rates during admission (18.2% vs. 27.3%). IE due to anaerobic bacteria is an uncommon disease that affects mainly prosthetic valves and frequently requires surgery. Otherwise, there are no major differences between AIE and IE caused by other microorganisms. Copyright © 2017 Elsevier Ltd. All rights reserved.
Aorta-atria-septum combined incision for aortic valve re-replacement
Xu, Yiwei; Ye, Xiaofeng; Li, Zhaolong
2018-01-01
This case report illustrates a patient who underwent supra-annular mechanical aortic valve replacement then suffered from prosthesis dysfunction, increasing pressure gradient with aortic valve. She was successfully underwent aortic valve re-replacement, sub-annular pannus removing and aortic annulus enlargement procedures through combined cardiac incision passing through aortic root, right atrium (RA), and upper atrial septum. This incision provides optimal visual operative field and simplifies dissection. PMID:29850170
Advances in cardiovascular fluid mechanics: bench to bedside.
Dasi, Lakshmi P; Sucosky, Philippe; de Zelicourt, Diane; Sundareswaran, Kartik; Jimenez, Jorge; Yoganathan, Ajit P
2009-04-01
This paper presents recent advances in cardiovascular fluid mechanics that define the current state of the art. These studies include complex multimodal investigations with advanced measurement and simulation techniques. We first discuss the complex flows within the total cavopulmonary connection in Fontan patients. We emphasize the quantification of energy losses by studying the importance of caval offsets as well as the differences among various Fontan surgical protocols. In our studies of the fluid mechanics of prosthetic heart valves, we reveal for the first time the full three-dimensional complexity of flow fields in the vicinity of bileaflet and trileaflet valves and the microscopic hinge flow dynamics. We also present results of these valves functioning in a patient-specific native aorta geometry. Our in vitro mitral valve studies show the complex mechanism of the native mitral valve apparatus. We demonstrate that the different components of the mitral valve have independent and synergistically complex functions that allow the valve to operate efficiently. We also show how valve mechanics change under pathological and repair conditions associated with enlarged ventricles. Finally, our ex vivo studies on the interactions between the aortic valve and its surrounding hemodynamic environment are aimed at providing insights into normal valve function and valve pathology. We describe the development of organ- and tissue-culture systems and the biological response of the tissue subjected to their respective simulated mechanical environment. The studies noted above have enhanced our understanding of the complex fluid mechanics associated with the cardiovascular system and have led to new translational technologies.
Actinomyces naeslundii: An Uncommon Cause of Endocarditis
Cortes, Christopher D.; Urban, Carl; Turett, Glenn
2015-01-01
Actinomyces rarely causes endocarditis with 25 well-described cases reported in the literature in the past 75 years. We present a case of prosthetic valve endocarditis (PVE) caused by Actinomyces naeslundii. To our knowledge, this is the first report in the literature of endocarditis due to this organism and the second report of PVE caused by Actinomyces. PMID:26697243
2010-01-01
Background This study was undertaken to compare mitral valve repair and replacement as treatments for ischemic mitral regurgitation (IMR) with left ventricular dysfunction (LVD). Specifically, we sought to determine whether the choice of mitral valve procedure affected survival, and discover which patients were predicted to benefit from mitral valve repair and which from replacement. Methods A total of 218 consecutive patients underwent either mitral valve repair (MVP, n = 112) or mitral valve replacement (MVR, n = 106). We retrospectively reviewed the clinical material, operation methods, echocardiography check during operation and follow-up. Patients details and follow-up outcomes were compared using multivariate and Kaplan-Meier analyses. Results No statistical difference was found between the two groups in term of intraoperative data. Early mortality was 3.2% (MVP 2.7% and MVR 3.8%). At discharge, Left ventricular end-systolic and end-diastolic diameter and left ventricular ejection fraction (LVEF) were improved more in the MVP group than MVR group (P < 0.05), however, in follow-up no statistically significant difference was observed between the MVR and MVP group (P > 0.05). Follow-up mitral regurgitation grade was significantly improved in the MVR group compared with the MVP group (P < 0.05). The Kaplan-Meier survival estimates at 1, 3, and 5 years were simlar between MVP and MVR group. Logistic regression revealed poor survival was associated with old age(#75), preoperative renal insufficiency and low left ventricular ejection fraction (< 30%). Conclusion Mitral valve repair is the procedure of choice in the majority of patients having surgery for severe ischemic mitral regurgitation with left ventricular dysfunction. Early results of MVP treatment seem to be satisfactory, but several lines of data indicate that mitral valve repair provided less long-term benefit than mitral valve replacement in the LVD patients. PMID:21059216
Forman, M B; Phelan, B K; Robertson, R M; Virmani, R
1985-02-01
Two-dimensional echocardiographic findings in porcine valve dysfunction were compared with pathologic findings in 10 patients (12 valves). Three specific echocardiographic findings were identified in patients with regurgitant lesions: prolapse, fracture and flail leaflets. Prolapse was associated pathologically with thinning of the leaflets, longitudinal tears close to the ring margin and acid mucopolysaccharide accumulation. Valve fracture was seen with and without prolapse and was accompanied pathologically by small pinpoint perforations or tears of the leaflet. A flail leaflet was seen with a linear tear of the free margin and was associated with calcific deposits. Mild degrees of fracture seen pathologically were missed on the echocardiographic study in five patients. Thickening or calcification, when present in moderate or severe amounts, was correctly identified by echocardiography. When all abnormal features were considered collectively, two-dimensional echocardiography correctly identified at least one of them in all patients. Therefore, two-dimensional echocardiography may prove useful in assessing the source of valvular regurgitation in patients with bioprosthetic valves.
NASA Astrophysics Data System (ADS)
Tan, Sean Guo-Dong; Kim, Sangho; Leo, Hwa Liang
2016-06-01
Mechanical heart valve prostheses are often implanted in young patients due to their durability and long-term reliability. However, existing designs are known to induce elevated levels of blood damage and blood platelet activation. As a result, there is a need for patients to undergo chronic anti-coagulation treatment to prevent thrombosis, often resulting in bleeding complications. Furthermore, recent studies have suggested that the implantation of a mechanical prosthetic valve at the mitral position results in a significant alteration of the left ventricular flow field which may contribute to flow turbulence. This study proposes a bi-leaflet mechanical heart valve design (Bio-MHV) that mimics the geometry of a human mitral valve, with the aim of reducing turbulence levels in the left ventricle by replicating physiological flow patterns. An in vitro three-dimensional particle velocimetry imaging experiment was carried out to compare the hemodynamic performance of the Bio-MHV with that of the clinically established ATS valve. The Bio-MHV was found to replicate physiological left ventricular flow patterns and produced lower turbulence levels.
A high risk critical mitral valve stenosis with emergency management at Apollo Hospitals Dhaka.
Zahangir, N M; Hoque, K Z; Khan, M H; Haque, M A; Haider, M Z
2013-10-01
Heart valve surgery in high-risk patients with severe jaundice, congestive hepatomegaly and renal impairment is associated with considerable morbidity and mortality. Without operation the consequences are invariably grave. A 35 years old gentleman with congestive cardiac failure was initially treated in coronary care unit (CCU). Mitral valve area was 0.5cm², pulmonary arterial systolic pressure (PASP) was 110mmHg, serum bilirubin was 20mg/dl, SGPT & SGOT were 1024iu/l and 1027iu/l respectively. Serum creatinine was 3.35mmol/l. Serum bilirubin gradually diminished to 3.1mg/dl after 12 days treatment in Coronary Care Unit but next day it increased to 3.6mg/dl. Mitral valve was replaced on an emergency basis. Echocardiogram on the 5th post operative day showed well functioning prosthetic mitral valve in situ. Serum bilirubin decreased to 2.2mg/dl, SGPT, SGOT and serum creatinine to 43iu/l, 40iu/l and 1.34mmol/l respectively. After 8 weeks of postoperative follow up his serum bilirubin decreased to 0.8mg/dl.
Boudjemline, Y; Laborde, F; Pineau, E; Mollet, A; Abadir, S; Bonhoeffer, P; Bonnet, D; Sidi, D
2006-05-01
This study was undertaken to develop a dilated valved conduit for reconstruction of the right ventricular outflow tract in the animal. The conduits were made by sewing a valved tube (Medtronic Inc) inside a vascular stent (Numed Inc). After preparation, they were inserted surgically in five lambs. The conduits were then dilated 6 weeks and 3 months after their implantation. Before sacrificing the animals at 3 months, a 22 mm valved stent was implanted percutaneously inside the surgical conduits. One animal died suddenly due to kinking of the conduit. Balloon dilatation was performed in the surviving animals. The first dilatation only had a modest impact on valvular function but it was much aggravated after the second dilatation. A valved stent was successfully inserted percutaneously. At sacrifice, all the conduits were completely engulfed in an intense fibrosis. In conclusion, a valved biological conduit for reconstruction of the right ventricular ejection tract has been developed and can be dilated sequentially to follow growth. The new product could have an important role to play in the management of congenital malformations involving the right ventricular outflow tract.
Deletion of CD73 in mice leads to aortic valve dysfunction.
Zukowska, P; Kutryb-Zajac, B; Jasztal, A; Toczek, M; Zabielska, M; Borkowski, T; Khalpey, Z; Smolenski, R T; Slominska, E M
2017-06-01
Aortic stenosis is known to involve inflammation and thrombosis. Changes in activity of extracellular enzyme - ecto-5'-nucleotidase (referred also as CD73) can alter inflammatory and thrombotic responses. This study aimed to evaluate the effect of CD73 deletion in mice on development of aortic valve dysfunction and to compare it to the effect of high-fat diet. Four groups of mice (normal-diet Wild Type (WT), high-fat diet WT, normal diet CD73-/-, high-fat diet CD73-/-) were maintained for 15weeks followed by echocardiographic analysis of aortic valve function, measurement of aortic surface activities of nucleotide catabolism enzymes as well as alkaline phosphatase activity, mineral composition and histology of aortic valve leaflets. CD73-/- knock out led to an increase in peak aortic flow (1.06±0.26m/s) compared to WT (0.79±0.26m/s) indicating obstruction. Highest values of peak aortic flow (1.26±0.31m/s) were observed in high-fat diet CD73-/- mice. Histological analysis showed morphological changes in CD73-/- including thickening and accumulation of dark deposits, proved to be melanin. Concentrations of Ca 2+ , Mg 2+ and PO 4 3- in valve leaflets were elevated in CD73-/- mice. Alkaline phosphatase (ALP) activity was enhanced after ATP treatment and reduced after adenosine treatment in aortas incubated in osteogenic medium. AMP hydrolysis in CD73-/- was below 10% of WT. Activity of ecto-adenosine deaminase (eADA), responsible for adenosine deamination, in the CD73-/- was 40% lower when compared to WT. Deletion of CD73 in mice leads to aortic valve dysfunction similar to that induced by high-fat diet suggesting important role of this surface protein in maintaining heart valve integrity. Copyright © 2017 Elsevier B.V. All rights reserved.
Wiley, Zanthia; Woodworth, Michael H; Jacob, Jesse T; Lockhart, Shawn R; Rouphael, Nadine G; Gullett, Jonathan C; Guarner, Jeannette; Workowski, Kimberly
2017-01-01
A patient who never resided in an endemic area for dimorphic fungi was diagnosed with Histoplasma capsulatum endocarditis. His diagnosis was suggested by yeast and hyphae on cardiac valve tissue pathology. Isavuconazole was an optimal therapeutic option due to renal dysfunction and anticoagulation with warfarin for mechanical valve replacement.
Wiley, Zanthia; Woodworth, Michael H; Jacob, Jesse T; Lockhart, Shawn R; Rouphael, Nadine G; Gullett, Jonathan C; Guarner, Jeannette
2017-01-01
Abstract A patient who never resided in an endemic area for dimorphic fungi was diagnosed with Histoplasma capsulatum endocarditis. His diagnosis was suggested by yeast and hyphae on cardiac valve tissue pathology. Isavuconazole was an optimal therapeutic option due to renal dysfunction and anticoagulation with warfarin for mechanical valve replacement. PMID:29255737
Davarpasand, Tahereh; Hosseinsabet, Ali; Jalali, Arash
2015-09-01
It has been reported that the short-term mortality of concomitant aortic and mitral valve replacement (AVR and MVR) is considerable and concomitant coronary artery bypass graft (CABG) has adverse effects on the survival of patients with valve replacement surgery. We summarize the short- and mid-term outcome after concomitant CABG, AVR and MVR in our centre. Between 2003 and 2013, 103 patients (68 males, 35 females, age: 60.1 ± 10.1 years) underwent CABG, AVR and MVR for rheumatic heart disease (RHD) and coronary artery disease (CAD). The median follow-up was 47.6 months. Most of the patients were asymptomatic at rest. We analysed demographic, clinical and operative data of patients to define independent predictors of overall survival, cardiac event-free survival as well as cardiac death. The rate of 30-day survival was 93% (n = 96). The corresponding rates of overall survival and cardiac event-free survival and the cumulative incidence rate of cardiac death at 1 year were 80.2, 77.3 and 10.9%; the same at 4 years were 73.7, 64.6 and 15.8%. The corresponding freedom rates from anticoagulation-associated major haemorrhage; a composite of major bleeding events, thromboemboli and valvular thrombosis; cardiac rehospitalization; major adverse valve-associated events; and significant malfunction of the prosthetic valve were 96.2, 95.3, 94.7, 81.6 and 97.7% at 1 year. The corresponding freedom rates from anticoagulation-associated major haemorrhage; a composite of major bleeding events, thromboemboli and valvular thrombosis; cardiac rehospitalization; major adverse valve-associated events; and significant malfunction of the prosthetic valve were 93.5, 91.0, 91.4, 73.5 and 95.5% at 4 years. The independent predictors of overall survival were age, cigarette smoking, chronic kidney diseases and balloon pump insertion. The independent predictors of cardiac event-free survival were age and previous myocardial infarction, while age, cigarette smoking, history of cerebrovascular accident and balloon pump insertion were the independent predictors of cardiac death. Concomitant CABG, AVR and MVR for rheumatic heart disease accompanied by CAD appear to have acceptable short- and mid-term outcomes with symptomatic amelioration. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Behr, Luc; Chetboul, Valérie; Sampedrano, Carolina Carlos; Vassiliki, Gouni; Pouchelon, Jean-Louis; Laborde, François; Borenstein, Nicolas
2007-04-01
To describe an open, beating heart surgical technique and use of a bovine pericardial prosthetic valve for mitral valve replacement (MVR) in the dog. Clinical case report. Male Bull Terrier (17-month-old, 26 kg) with mitral valve dysplasia and severe regurgitation. A bovine pericardial bioprosthesis was used to replace the mitral valve using an open beating heart surgical technique and cardiopulmonary bypass. Successful MVR was achieved using a beating heart technique. Mitral regurgitation resolved and cardiac performances improved (left ventricular end-diastolic diameter decreased from 57.6 to 48.7 mm, and left atrium/aorta ratio returned to almost normal, from 1.62 to 1.19). Cardiopulmonary by-pass time and total surgical duration were decreased compared with standard cardioplegic techniques. Surgical recovery was uneventful and on echocardiography 6 months later valve function was excellent. Considering the technique advantages (no cardiac arrest, ischemic reperfusion injury, and hypothermia, or the need for aortic dissection and cannulation for administration of cardioplegic solution), short-term mortality and morbidity may be reduced compared with standard cardioplegic techniques. Based on experience in this dog, beating heart mitral valvular replacement is a seemingly safe and viable option for the dog and bovine pericardial prosthesis may provide better long-term survival than mechanical prostheses.
Leaflet escape in a new bileaflet mechanical valve: TRI technologies.
Bottio, Tomaso; Casarotto, Dino; Thiene, Gaetano; Caprili, Luca; Angelini, Annalisa; Gerosa, Gino
2003-05-13
Leaflet escape is a mode of structural valve failure for mechanical prostheses. This complication previously has been reported for both monoleaflet and bileaflet valve models. We report 2 leaflet escape occurrences observed in 2 patients who underwent valve replacement with a TRI Technologies valve prosthesis. At the University of Padua, between November 2000 and February 2002, 36 TRI Technologies valve prostheses (26 aortic and 10 mitral) were implanted in 34 patients (12 women and 22 men) with a mean age of 59.9+/-10.3 years (range, 30 to 75 years). There were 5 deaths: 3 in hospital, 1 early after discharge, and 1 late. Two patients experienced a catastrophic prosthetic leaflet escape; the first patient was a 52-year-old man who died 10 days after aortic valve and ascending aorta replacement, and the second was a 58-year-old man who underwent a successful emergency reoperation 20 months after mitral valve replacement. Examination of the explanted prostheses showed in both cases a leaflet escape caused by a leaflet's pivoting system fracture. Prophylactic replacement was then successfully accomplished so far in 12 patients, without evidence of structural valve failure in any of them. Among other significant postoperative complications, we observed 3 major thromboembolisms, 1 hemorrhage, and 1 paravalvular leak. These catastrophes prompted us to interrupt the implantation program, and they cast a shadow on the durability of the TRI Technologies valve prosthesis because of its high risk of structural failure.
Ericsson, A; Lindblom, D; Semb, G; Huysmans, H A; Thulin, L I; Scully, H E; Bennett, J G; Ostermeyer, J; Grunkemeier, G L
1992-01-01
Between 1980 and 1983, 831 Björk-Shiley 70 degrees convexo-concave prosthetic heart valves were implanted at five institutions in Sweden, Germany. The Netherlands, and Canada. As of January 1991, there were 34 outlet strut fractures occurring from 0.2 to 10.1 years (median = 4.6 years) after implantation. In addition, there were 28 sudden, unexplained deaths. The mortality after strut fracture was 84%. The mortality after emergency valve replacement for strut fracture was 50%. The 10-year actuarial fracture rate (standard error) was 10.5 (2.4)% for large (29-33 mm) valves vs. 3.3 (1.2)% for 21-27 mm valves (P less than 0.001). Within valve size groups, fracture rates for aortic and mitral valves were similar. Cox regression analysis found only valve size to be significantly associated with strut fracture. There is a further subgrouping of the valves according to the manufacturer: group I are the earlier large 29-33 mm) valves; group II are the later large valves; group III are the small size (21-27 mm) valves. The risk of strut fracture was highest in group I (12.3% at 10 years) with an approximatively constant hazard (1.4% per year). A comparison was made with a statistical model incorporating all cases reported to the manufacturer. This model estimates fracture rates approximately 63%-73% of those found in the present study. These findings lead us to recommend that group I patients should be considered for elective reoperation on an individual basis, giving careful attention to risk factors and contraindications.
Lee, Justin Z; Tey, Kai R; Mizyed, Ahmad; Hennemeyer, Charles T; Janardhanan, Rajesh; Lotun, Kapildeo
2015-10-09
Left ventricular outflow tract (LVOT) obstruction and paravalvular leak (PVL) are relatively uncommon, but are serious complications of prosthetic valve replacement. We present a case that displays the unique therapeutic challenges of treating a patient who developed both LVOT obstruction and mitral PVL after undergoing surgical aortic and mitral valve replacement (MVR). We also describe the use of alcohol septal ablation and albumin-glutaraldehyde (BioGlue) for septal ablation to percutaneously treat the patient's LVOT obstruction, followed by use of an Amplatzer vascular plug for percutaneous closure of an antero-medial mitral PVL associated with severe regurgitation. Percutaneous interventional management of these entities may be considered as an initial therapeutic option, especially in high-risk patients with significant morbidity and mortality of repeat surgical operations.
Effect of Botox injection at the bladder neck in boys with bladder dysfunction after valve ablation.
Mokhless, Ibrahim; Zahran, Abdel-Rahman; Saad, Ashraf; Yehia, Mohamed; Youssif, Mohamed E
2014-10-01
After posterior urethral valve ablation, some boys are still have a hostile bladder. We conducted a prospective randomized study to determine if Botox injection at the bladder neck will help improve vesical dysfunction in this subgroup of boys or not. Twenty boys with history of posterior urethral valve ablation and severe bladder dysfunction with a mean age of 16 months were studied. Cases were further randomized into two groups. Group I (study group) had endoscopic injection of a single dose of 100 IU of Botox into the hypertrophied bladder neck at 3, 6, and 9 o'clock. Group II (control group) patients with the same parameters had urethroscopy to exclude residual valves. Both groups had the standard conservative treatment. Cases were followed after 6 months of initiating the management protocol. This includes laboratory studies (urine culture and sensitivity, blood urea nitrogen, serum creatinine), ultrasound of the urinary tract. Voiding cysto-urethrogram and urodynamic study (pressure flow study). There was no statistical difference in both groups regarding rate of urinary tract infection, improvement of hydronephrosis, resolution of vesico-ureteral reflux, creatinine level at the start or at the end of the study. Urodynamic parameters revealed an increase in cystometric capacity in both groups at the end of the study but without statistical difference. The mean voiding pressure reduced significantly in both groups but without statistical difference. Temporarily abolishing the effect of bladder neck by Botox injection does not seem to improve the outcome of those boys who had a severe voiding dysfunction after valve ablation. Copyright © 2014 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Weitsman, Tatyana; Weisz, Giora; Farkash, Rivka; Klutstein, Marc; Butnaru, Adi; Rosenmann, David; Hasin, Tal
2017-11-01
Pulmonary hypertension has many causes. While it is conventionally thought that the most prevalent is left heart disease, little information about its proportion, causes, and implications on outcome is available. Between 1993 and 2015, 12,115 of 66,949 (18%) first adult transthoracic echocardiograms were found to have tricuspid incompetence gradient ≥40 mm Hg, a pulmonary hypertension surrogate. Left heart disease was identified in 8306 (69%) and included valve malfunction in 4115 (49%), left ventricular systolic dysfunction in 2557 (31%), and diastolic dysfunction in 1776 (21%). Patients with left heart disease, as compared with those without left heart disease, were of similar age, fewer were females (50% vs 63% P <.0001), and they had higher tricuspid incompetence gradient (median 48 mm Hg [interquartile range 43, 55] vs 46 mm Hg [42, 54] P <.0001). In reviewing trends over 20 years, the relative proportions of systolic dysfunction decreased and diastolic dysfunction increased (P for trend <.001), while valve malfunction remained the most prevalent cause of pulmonary hypertension with left heart disease. Independent predictors of mortality were age (hazard ratio [HR] 1.05; 95% CI, 1.04-1.05; P <.0001), tricuspid incompetence gradient (HR 1.02; 95% CI, 1.01-1.02, P <.0001 per mm Hg increase), and female sex (HR 0.87; 95% CI, 0.83-0.91, P <.0001). Overall, left heart disease was not an independent risk factor for mortality (HR 1.04; 95% CI, 0.99-1.09; P = .110), but patients with left ventricular systolic dysfunction and with combined systolic dysfunction and valve malfunction had increased mortality compared with patients with pulmonary hypertension but without left heart disease (HR 1.30; 95% CI, 1.20-1.42 and HR 1.44; 95% CI, 1.33-1.55, respectively; P <.0001 for both). Pulmonary hypertension was found to be associated with left heart disease in 69% of patients. Among these patients, valve malfunction and diastolic dysfunction emerged as prominent causes. Left ventricular dysfunction carries additional risk to patients with pulmonary hypertension. Copyright © 2017 Elsevier Inc. All rights reserved.
Should patients with Björk-Shiley valves undergo prophylactic replacement?
Birkmeyer, J D; Marrin, C A; O'Connor, G T
1992-08-29
About 85,000 patients have undergone replacement of diseased heart valves with prosthetic Björk-Shiley convexo-concave (CC) valves. These valves are prone to fracture of the outlet strut, which leads to acute valve failure that is usually fatal. Should patients with these valves undergo prophylactic replacement to avoid fracture? The incidence of strut fracture varies between 0% and 1.5% per year, depending on valve opening angle (60 degrees or 70 degrees), diameter (less than 29 mm or greater than or equal to 29 mm), and location (aortic or mitral). Other factors include the patient's life expectancy and the expected morbidity and mortality associated with reoperation. We have used decision analysis to identify the patients most likely to benefit from prophylactic reoperation. The incidence of outlet strut fracture was estimated from the data of three large studies on CC valves, and stratified by opening angle, diameter, and location. A Markov decision analysis model was used to estimate life expectancy for patients undergoing prophylactic valve replacement and for those not undergoing reoperation. Prophylactic valve replacement does not benefit patients with CC valves that have low strut fracture risks (60 degrees aortic valves and less than 29 mm, 60 degrees mitral valves). For most patients with CC valves that have high strut fracture risks (greater than or equal to 29 mm, 70 degrees CC), prophylactic valve replacement increases life expectancy. However, elderly patients with such valves benefit from prophylactic reoperation only if the risk of operative mortality is low. Patient age and operative risk are most important in recommendations for patients with CC valves that have intermediate strut fracture risks (less than 29 mm, 70 degrees valves and greater than or equal to 29 mm, 60 degrees mitral valves). For all patients and their doctors facing the difficult decision on whether to replace CC valves, individual estimates of operative mortality risk that take account of both patient-specific and institution-specific factors are essential.
Joo, Hyung Joon; Hong, Soon Jun; Yu, Cheol Woong
2015-03-01
A 43-year-old man presented with severe aortic stenosis. Eight years previously, he had undergone primary surgical aortic valve replacement (AVR) for severe aortic regurgitation, but one year later developed cardiac arrest and complete atrioventricular block as a result of non-bacterial thrombotic endocarditis with severe valvular dehiscence. Following the diagnosis of prosthetic valve failure caused by Behçet's disease, the patient underwent a Bentall operation using 23 mm aortic homograft with permanent pacemaker implantation and coronary artery bypass grafting. Subsequently, he was stable with steroid administration and azathioprine for seven years after the second operation, but recently suffered from severe dyspnea and chest pain. Echocardiography revealed the development of severe aortic stenosis. A preprocedural evaluation demonstrated a porcelain aorta with severe calcification in the previous homograft valve on computed tomography, and critical stenosis at the ostium of the left circumflex artery on coronary angiography. After percutaneous coronary intervention for the ostium of the left circumflex artery, a transcatheter AVR was successfully performed using a 26 mm Edwards SAPIEN XT valve. The patient recovered without any complications after the procedure. This is the first report of a successful transcatheter aortic valve-in valve implantation for severe homograft aortic stenosis after a Bentall operation, using a homograft, in a patient with Behçet's disease.
Noncardiogenic Pulmonary Edema as a Result of Urosepsis
2010-03-01
cause could be aortic stenosis , which may require surgery to correct, or it could be coronary artery disease, which can be treated through a variety...systolic dysfunction. Left ventricular dysfunction can occur due to many processes such as aortic or mitral valve dysfunction, coronary artery disease
Incidence of Otolaryngological Symptoms in Patients with Temporomandibular Joint Dysfunctions
Ferendiuk, E.; Zajdel, K.
2014-01-01
The functional disorders of the masticatory organ are the third stomatological disease to be considered a populational disease due to its chronicity and widespread prevalence. Otolaryngological symptoms are a less common group of dysfunction symptoms, including sudden hearing impairment or loss, ear plugging sensation and earache, sore and burning throat, difficulties in swallowing, tinnitus, and vertigo. The diagnostic and therapeutic problems encountered in patients with the functional disorders of the masticatory organ triggered our interest in conducting retrospective studies with the objective of assessing the incidence of otolaryngological symptoms in patients subjected to prosthetic treatment of the functional disorders of masticatory organ on the basis of the analysis of medical documentation containing data collected in medical interviews. Material and Methods. Retrospective study was conducted by analyzing the results of medical interviews of 1208 patients, who had reported for prosthetic treatment at the Functional Disorders Clinic of the Department of Dental Prosthetics of Jagiellonian University Medical College in Cracow between 2008 and March 14, 2014. Results. Otolaryngological symptoms were observed in 141 patients. The most common symptoms in the study group were earache and sudden hearing impairment; no cases of sudden hearing loss were experienced. PMID:25050373
Lindsay, Alistair C; Harron, Katie; Jabbour, Richard J; Kanyal, Ritesh; Snow, Thomas M; Sawhney, Paramvir; Alpendurada, Francisco; Roughton, Michael; Pennell, Dudley J; Duncan, Alison; Di Mario, Carlo; Davies, Simon W; Mohiaddin, Raad H; Moat, Neil E
2016-07-01
Cardiovascular magnetic resonance (CMR) can provide important structural information in patients undergoing transcatheter aortic valve implantation. Although CMR is considered the standard of reference for measuring ventricular volumes and mass, the relationship between CMR findings of right ventricular (RV) function and outcomes after transcatheter aortic valve implantation has not previously been reported. A total of 190 patients underwent 1.5 Tesla CMR before transcatheter aortic valve implantation. Steady-state free precession sequences were used for aortic valve planimetry and to assess ventricular volumes and mass. Semiautomated image analysis was performed by 2 specialist reviewers blinded to patient treatment. Patient follow-up was obtained from the Office of National Statistics mortality database. The median age was 81.0 (interquartile range, 74.9-85.5) years; 50.0% were women. Impaired RV function (RV ejection fraction ≤50%) was present in 45 (23.7%) patients. Patients with RV dysfunction had poorer left ventricular ejection fractions (42% versus 69%), higher indexed left ventricular end-systolic volumes (96 versus 40 mL), and greater indexed left ventricular mass (101 versus 85 g/m(2); P<0.01 for all) than those with normal RV function. Median follow-up was 850 days; 21 of 45 (46.7%) patients with RV dysfunction died, compared with 43 of 145 (29.7%) patients with normal RV function (P=0.035). After adjustment for significant baseline variables, both RV ejection fraction ≤50% (hazard ratio, 2.12; P=0.017) and indexed aortic valve area (hazard ratio, 4.16; P=0.025) were independently associated with survival. RV function, measured on preprocedural CMR, is an independent predictor of mortality after transcatheter aortic valve implantation. CMR assessment of RV function may be important in the risk stratification of patients undergoing transcatheter aortic valve implantation. © 2016 American Heart Association, Inc.
O’Rourke, Timothy K.; Erbella, Alexander; Zhang, Yu
2017-01-01
Penile prosthesis implant surgery is an effective management approach for a number of urological conditions, including medication refractory erectile dysfunction (ED). Complications encountered post-operatively include infection, bleeding/hematoma, and device malfunction. Since the 1970s, modifications to these devices have reduced complication rates through improvement in antisepsis and design using antibiotic coatings, kink-resistant tubing, lock-out valves to prevent autoinflation, and modified reservoir shapes. Device survival and complication rates have been investigated predominately by retrospective database-derived studies. This review article focuses on the identification and management of post-operative complications following penile prosthetic and implant surgery. Etiology for ED, surgical technique, and prosthesis type are variable among studies. The most common post-operative complications of infection, bleeding, and device malfunction may be minimized by adherence to consistent technique and standard protocol. Novel antibiotic coatings and standard antibiotic regimen may reduce infection rates. Meticulous hemostasis and intraoperative testing of devices may further reduce need for revision surgery. Additional prospective studies with consistent reporting of outcomes and comparison of surgical approach and prosthesis type in patients with variable ED etiology would be beneficial. PMID:29238663
Scotten, Lawrence N; Siegel, Rolland
2015-08-01
Exploration for causes of prosthetic valve thrombogenicity has frequently focused on forward or post-closure flow detail. In prior laboratory studies, we uncovered high amplitude flow velocities of short duration close to valve closure implying potential for substantial shear stress with subsequent initiation of blood coagulation pathways. This may be relevant to widely accepted clinical disparity between mechanical and tissue valves vis-à-vis thrombogenicity. With a series of prototype bi-leaflet mechanical valves, we attempt reduction of closure related velocities with the objective of identifying a prototype valve with thrombogenic potential similar to our tissue valve control. This iterative design approach may find application in preclinical assessment of valves for anticoagulation independence. Tested valves included: prototype mechanical bi-leaflet BVs (n=56), controls (n=2) and patented early prototype mechanicals (n=2) from other investigators. Pulsatile and quasi-steady flow systems were used for testing. Projected dynamic valve area (PDVA) was measured using previously described novel technology. Flow velocity over the open and closing periods was determined by volumetric flow rate/PDVA. For the closed valve interval, use was made of data obtained from quasi-steady back pressure/flow tests. Performance was ranked by a proposed thrombogenicity potential index (TPI) relative to tissue and mechanical control valves. Optimization of the prototype valve designs lead to a 3-D printed model (BV3D). For the mitral/aortic site, BV3D has lower TPI (1.10/1.47) relative to the control mechanical valve (3.44/3.93) and similar to the control tissue valve (ideal TPI ≤1.0). Using unique technology, rapid prototyping and thrombogenicity ranking, optimization of experimental valves for reduced thrombogenic potential was expedited and simplified. Innovative mechanical valve configurations were identified that merit consideration for further development which may bring the anti-coagulation independent mechanical valve within reach.
Siegel, Rolland
2015-01-01
Background Exploration for causes of prosthetic valve thrombogenicity has frequently focused on forward or post-closure flow detail. In prior laboratory studies, we uncovered high amplitude flow velocities of short duration close to valve closure implying potential for substantial shear stress with subsequent initiation of blood coagulation pathways. This may be relevant to widely accepted clinical disparity between mechanical and tissue valves vis-à-vis thrombogenicity. With a series of prototype bi-leaflet mechanical valves, we attempt reduction of closure related velocities with the objective of identifying a prototype valve with thrombogenic potential similar to our tissue valve control. This iterative design approach may find application in preclinical assessment of valves for anticoagulation independence. Methods Tested valves included: prototype mechanical bi-leaflet BVs (n=56), controls (n=2) and patented early prototype mechanicals (n=2) from other investigators. Pulsatile and quasi-steady flow systems were used for testing. Projected dynamic valve area (PDVA) was measured using previously described novel technology. Flow velocity over the open and closing periods was determined by volumetric flow rate/PDVA. For the closed valve interval, use was made of data obtained from quasi-steady back pressure/flow tests. Performance was ranked by a proposed thrombogenicity potential index (TPI) relative to tissue and mechanical control valves. Results Optimization of the prototype valve designs lead to a 3-D printed model (BV3D). For the mitral/aortic site, BV3D has lower TPI (1.10/1.47) relative to the control mechanical valve (3.44/3.93) and similar to the control tissue valve (ideal TPI ≤1.0). Conclusions Using unique technology, rapid prototyping and thrombogenicity ranking, optimization of experimental valves for reduced thrombogenic potential was expedited and simplified. Innovative mechanical valve configurations were identified that merit consideration for further development which may bring the anti-coagulation independent mechanical valve within reach. PMID:26417581
The double switch for atrioventricular discordance.
Brawn, William J
2005-01-01
Conventional surgery for atrioventricular discordance usually associated with ventricular arterial discordance leaves the morphologic right ventricle in the systemic circulation. Long-term follow-up results with this approach reveal a high incidence of right ventricular failure. The double switch procedure was introduced to restore the morphologic left ventricle to the systemic circulation. This operation is performed in two main ways: the atrial-arterial switch and the atrial switch plus Rastelli procedure. This double switch approach has been successful at least in the medium term in abolishing morphologic right ventricular failure and its associated tricuspid valve regurgitation. In the atrial-arterial switch group, there is an incidence of morphologic left ventricular dysfunction, sometimes associated with neoaortic valve regurgitation, and the minority of cases need aortic valve replacement. The long-term function of the morphologic left ventricle and the aortic valve need careful surveillance in the future. The atrial-Rastelli group of patients has not in the medium term shown evidence of ventricular dysfunction but will require change on a regular basis of their ventricular to pulmonary artery valved conduits.
Bartonella endocarditis in complex congenital heart disease.
Hoffman, Risa M; AboulHosn, Jamil; Child, John S; Pegues, David A
2007-01-01
Bartonella species are an important cause of culture-negative endocarditis, with recognized risk factors of alcoholism, homelessness, cat exposure, and pre-existing valvular disease. We report a case of Bartonella henselae endocarditis in a 36-year-old woman with complex congenital heart disease who presented with a 7-month history of hemolytic anemia, leukocytoclastic vasculitis, and recurrent fevers. Transesophageal echocardiogram revealed vegetations on the patient's native aortic valve and in the right ventricular to pulmonary artery conduit and associated bioprosthetic valve. Diagnosis of B. henselae was confirmed with serum antibody and polymerase chain reaction (PCR) testing and tissue stains. The patient was treated successfully with surgical resection and prolonged antimicrobial therapy with ceftriaxone, gentamicin, and doxycycline. A review of the literature suggests prosthetic valves and complex congenital heart disease are risk factors for Bartonella endocarditis, and a high index of suspicion with antibody and PCR testing can expedite diagnosis and improve outcomes.
Ritchie, R O; Dauskardt, R H; Pennisi, F J
1992-01-01
A scanning electron microscopy study is reported of the nature and morphology of fracture surfaces in pyrocarbons commonly used for the manufacture of mechanical heart-valve prostheses. Specifically, silicon-alloyed low-temperature-isotropic (LTI)-pyrolytic carbon is examined, both as a coating on graphite and as a monolithic material, following overload, stress corrosion (static fatigue), and cyclic fatigue failures in a simulated physiological environment of 37 degrees C Ringer's solution. It is found that, in contrast to most metallic materials yet in keeping with many ceramics, there are no distinct fracture morphologies in pyro-carbons which are characteristic of a specific mode of loading; fracture surfaces appear to be identical for both catastrophic and subcritical crack growth under either sustained or cyclic loading. We conclude that caution should be used in assigning the likely cause of failure of pyrolytic carbon heart-valve components using fractographic examination.
Litton, Kayleigh M; Rogers, Bret A
2016-01-01
Edwardsiella tarda is a freshwater marine member of the family Enterobacteriaceae which often colonizes fish, lizards, snakes, and turtles but is an infrequent human pathogen. Indium-111- ((111)In-) labeled white blood cell (WBC) scintigraphy is an imaging modality which has a wide range of reported sensitivity and specificity (from 60 to 100% and from 68 to 92%, resp.) for diagnosing acute and chronic infection. We describe a case of suspected E. tarda prosthetic aortic valve and mitral valve endocarditis with probable vegetations and new mitral regurgitation on transthoracic and transesophageal echocardiograms which was supported with the use of (111)In-labeled WBC scintigraphy.
Prosthetic valve sparing aortic root replacement: an improved technique.
Leacche, Marzia; Balaguer, Jorge M; Umakanthan, Ramanan; Byrne, John G
2008-10-01
We describe a modified surgical technique to treat patients with a previous history of isolated aortic valve replacement who now require aortic root replacement for an aneurysmal or dissected aorta. This technique consists of replacing the aortic root with a Dacron conduit, leaving intact the previously implanted prosthesis, and re-implanting the coronary arteries in the Dacron graft. Our technique differs from other techniques in that we do not leave behind any aortic tissue remnant and also in that we use a felt strip to obliterate any gap between the old sewing ring and the newly implanted graft. In our opinion, this promotes better hemostasis. We demonstrate that this technique is safe, feasible, and results in acceptable outcomes.
Cardiac Surgery in Patients Infected with Human Immunodeficiency Virus
Abad, Cipriano; Cárdenes, Miguel Angel; Jiménez, Pedro Conrado; Armas, Mario-Vicente; Betancor, Pedro
2000-01-01
From January 1991 through December 1999, 5 consecutive patients who were infected with human immunodeficiency virus presented in need of cardiac surgery. All were men; the median age was 44 years. Two of them presented with mitral and aortic infectious valve endocarditis, 1 with tricuspid endocarditis, 1 with prosthetic valve endocarditis, and 1 with pericarditis and pericardial tamponade. Under cardiopulmonary bypass, the 4 patients with endocarditis underwent these procedures: mitral and aortic valve replacement (2), tricuspid valve replacement (1), and aortic valve replacement (reoperation) and concomitant repair of a mycotic ascending aortic aneurysm (1). In the patient who had pericardial effusion, subxifoid pericardiostomy and drainage were performed, and a pericardial window was created. There was no intraoperative mortality. The patient with pericardial effusion died 8 days after surgery; he was in septic shock and had multiple organ failure. Two deaths occurred at 2 and 63 months, due to hemoptysis and sudden death, respectively. The 2 patients who underwent double valve replacement are alive and in good condition after a median follow-up of 71 months. Cardiac surgery is indicated in selected patients infected by the human immunodeficiency virus. These patients are frequently drug abusers or homosexual. Valvular endocarditis is the most common finding. Hospital morbidity and mortality rates are higher than usual in this group of patients. PMID:11198308
Superhydrophobicity to minimize thrombogenic risk on mechanical heart valves
NASA Astrophysics Data System (ADS)
Bark, David; Vahabi, Hamed; Movafaghi, Sanli; Popat, Ketul; Kota, Arun K.; Dasi, Lakshmi Prasad
2017-11-01
A large number of prosthetic heart valves are implanted each year to treat heart valve disease, where half of the surgically replaced valves are mechanical heart valves (MHV)s. MHVs are at high risk for thrombosis and therefore require lifelong antithrombotic therapies, causing an increased bleeding risk that can lead to death. To alleviate this need, we investigate the potential of superhydrophobic surfaces in reducing the thrombotic risk. Particle imaging velocimetry and computational fluid dynamics are used to quantify shear stress in the presence of potential slip on the surface. Coagulation and cell adhesion are quantified by incubating blood under static conditions. We further evaluate a dynamic blood response in polydimethylsiloxane channels under complex shear conditions that mimic the hinge region of bileaflet mechanical heart valves, a region known to exhibit thrombosis. Overall, Shear stress is not reduced on a superhydrophobic bileaflet MHV. However, superhydrophobic surfaces significantly reduce the potential for platelet responses under static and dynamic blood flow conditions, a counterintuitive result when considering that hydrophobic surfaces are prone to protein and cell adhesion. The authors gratefully acknowledge funding from National Institutes of Health (NIH) under Award Number R01HL119824 and F32HL129730. The content is solely the responsibility of the authors and does not necessarily represent the official views of the NIH.
Non-cardiac surgery in patients with prosthetic heart valves: a 12 years experience.
Akhtar, Raja Parvez; Abid, Abdul Rehman; Zafar, Hasnain; Gardezi, Syed Javed Raza; Waheed, Abdul; Khan, Jawad Sajid
2007-10-01
To study patients with mechanical heart valves undergoing non-cardiac surgery and their anticoagulation management during these procedures. It was a cohort study. The study was conducted at the Department of Cardiac Surgery, Punjab Institute of Cardiology, Lahore and Department of Surgery, Services Institute of Medical Sciences, Lahore, from September 1994 to June 2006. Patients with mechanical heart valves undergoing non-cardiac surgical operation during this period, were included. Their anticoagulation was monitored and anticoagulation related complications were recorded. In this study, 507 consecutive patients with a mechanical heart valve replacement were followed-up. Forty two (8.28%) patients underwent non-cardiac surgical operations of which 24 (57.1%) were for abdominal and non-abdominal surgeries, 5 (20.8%) were emergency and 19 (79.2%) were planned. There were 18 (42.9%) caesarean sections for pregnancies. Among the 24 procedures, there were 7(29.1%) laparotomies, 7(29.1%) hernia repairs, 2 (8.3%) cholecystectomies, 2 (8.3%) hysterectomies, 1(4.1%) craniotomy, 1(4.1%) spinal surgery for neuroblastoma, 1(4.1%) ankle fracture and 1(4.1%) carbuncle. No untoward valve or anticoagulation related complication was seen during this period. Patients with mechanical valve prosthesis on life-long anticoagulation, if managed properly, can undergo any type of non-cardiac surgical operation with minimal risk.
Nosocomial Endocarditis Caused by Corynebacterium amycolatum and Other Nondiphtheriae Corynebacteria
Holmes, Alison H.
2002-01-01
The nondiphtheriae corynebacteria are uncommon but increasingly recognized as important agents of community-acquired endocarditis in patients with underlying structural heart disease, as well as of prosthetic-valve endocarditis. We describe three cases of nondiphtheriae corynebacterial endocarditis, including the first reported case of endocarditis caused by Corynebacterium amycolatum, occurring over an 18-month period, all in association with indwelling intravascular devices. PMID:11749760
New Heart Failure Treatment Capability for Remote Environments
2013-06-01
valve in a cycle manner. Control of the absolute pressure, rate of actuation and resistance in the 19 drive lines were the manner in which...Hegde SS, Lowe JE. Sensing Lead Insulation Fractures Following Implantable Cardioverter-Defibrillator Placement. ASAIO Journal 1993;39:M711-M714...14:45-46,1985. Anstadt MP, Galbraith TA, Murray KD, Howanitz EP, Myerowitz PD: Bridge to Cardiac Transplantation Using Prosthetic Biventricular
[Transcatheter aortic valve replacement].
Sawa, Yoshiki
2014-07-01
While transcatheter aortic valve replacement( TAVR) has spread rapidly all over the world for highrisk patients with severe aortic stenosis (AS), SAPIEN XT was approved in Japan in October 2013. Since that, approximately 400 TAVR cases were performed in Japan. In our institute, we have performed 164 cases since first case in Japan in 2009 and have achieved satisfactory early results(30-day mortality:1.2%). At the same time, however, simultaneously various TAVR-related complications including a paravalvular leak, stroke, vascular complications, and coronary obstruction were observed. A reduction in the incidence and severity of these complications had led technical improvements in various new devices(2nd generation TAVR device such as the SAPIEN 3, ACURATE, and JenaValve) and in implantation techniques including repositioning/recapturing features, paravalvular sealing technologies, and prevention of coronary obstruction. Furthermore, there is also increasing experience with special indications for TAVR such as pure aortic valve insufficiency or valve-in-valve techniques. Currently, an increasing number of publications of midterm results demonstrate good prosthetic valve function and durability, with good quality of life and low morbidity after TAVR. There are also some randomized trials such as PARTNER 2 or SURTAVI to investigate potential benefits of TAVR for intermediate-risk patients. These improvements in the TAVR devices promises the expansion of TAVR towards the treatment of lower-risk patients in the near future.
Further evidence of gaseous embolic material in patients with artificial heart valves.
Georgiadis, D; Baumgartner, R W; Karatschai, R; Lindner, A; Zerkowski, H R
1998-04-01
We undertook this study to evaluate the hypothesis that most microemboli signals in patients with artificial heart valves are gaseous, assuming that microemboli counts in cerebral arteries would progressively decline with increasing distance from the generating heart valve. A total of 10 outpatients with CarboMedics (Sulzer Carbomedics Inc., n = 5) and ATS prosthetic heart valves (n = 5) in the aortic (n = 8), mitral (n = 1), or both aortic and mitral positions (n = 1) were recruited. Monitoring was performed simultaneously over the middle and anterior cerebral arteries and the common carotid artery for 30 minutes with the 2 MHZ transducers of a color duplex scanner (common carotid artery) and pulsed-wave Doppler ultrasonography (intracranial arteries). All data were harvested in an eight-channel digital audio tape recorder, and microembolic signal counts were evaluated online by two separate observers. Significantly higher microembolic signal counts were recorded in the common carotid artery (112 [75 to 175]) compared with the middle and anterior cerebral arteries (30 [18 to 36], p < 0.0001). Interobserver variability was satisfactory (k = 0.81). Our results strongly argue for gaseous underlying embolic material in patients with artificial heart valves because bubbles are bound to implode with time.
Von Der Emde J, J; Eberlein, U; Breme J, J
1990-01-01
From August 1971 through November 1972, we implanted 62 Model 2 DeBakey-Surgitool aortic valve prostheses in 62 patients, 4 of whom later had clinically asymptomatic strut fractures. In 1 case, the patient died suddenly, and autopsy revealed detachment of the ball-cage; in each of the other 3 cases, fractures of 2 struts close to the base of the prosthesis were diagnosed fluoroscopically, and the patients underwent successful reoperation. The interval between implantation and reoperation ranged from 11 months to 16 years, 9 months. In 1 patient, retrospective study of chest radiographs revealed that the fracture had been present for 2(1/2) years. Larger valves (>/= A6) were affected significantly more often than smaller ones. We performed metallurgic analysis of 1 prosthesis: results revealed strut wear from fatigue cracking and secondary abrasion. Strut fracture was also promoted by suspension of the cage at right angles to the prosthetic ring and by use of a pyrolytic carbon ball in a titanium cage (i.e., an occluder harder than its holder). Patients with DeBakey-Surgitool aortic valve prostheses should undergo annual radiologic examinations to enable early detection of strut fractures. Prophylactic valve replacement is not indicated.
Urgent splenectomy in the course of prosthetic valve endocarditis.
Marcinkiewicz, Anna; Ostrowski, Stanisław; Pawłowski, Witold; Palczak, Artur; Adamek-Kośmider, Anna; Jaszewski, Ryszard
2014-06-01
We present a case of a 51-year-old male patient hospitalized due to acute coronary syndrome requiring stent implantation to the left main stem. Double antiplatelet therapy was commenced. After 2-3 days, the patient presented with high fever, dyspnea on exertion, pain in the chest, myalgia, and general weakness. Transthoracic (TTE) and transesophageal (TEE) echocardiography revealed abnormal, turbulent flow across the aortic prosthesis, which was probably caused by the presence of a pathological smooth and mobile structure (10 × 9 × 5 mm) in front of the aortic annulus. Blood cultures were positive and staphylococcal prosthetic valve endocarditis (PVE) was diagnosed. Despite antibiotic treatment, the patient's condition deteriorated, and he was referred for prosthesis reimplantation. After being transferred to the Cardiac Surgery Clinic, he presented with nausea, vomiting, and abdominal pain. The results of imaging examinations suggested spleen hematoma. The patient underwent an urgent splenectomy. Histopathological examination revealed a spleen infarction consequent to an embolic event and subscapular hematoma. On the 10(th) day after the laparotomy, cardiac surgery was performed. No large vegetations were found on the aortic prosthesis. The mechanical valve, implanted 20 years earlier, was functioning properly; it was intact and well healed. Several fragments of a thrombus and fibrous tissue, resembling a pannus and covered with minor calcifications, were removed from the ventricular surface of the discs. A decision was reached to leave the aortic prosthesis in situ. The valvular material culture revealed the presence of Streptococcus anginosus, and the antibiotic scheme was modified. The postoperative period was uneventful.
Prognostic Implications of Raphe in Bicuspid Aortic Valve Anatomy.
Kong, William K F; Delgado, Victoria; Poh, Kian Keong; Regeer, Madelien V; Ng, Arnold C T; McCormack, Louise; Yeo, Tiong Cheng; Shanks, Miriam; Parent, Sarah; Enache, Roxana; Popescu, Bogdan A; Liang, Michael; Yip, James W; Ma, Lawrence C W; Kamperidis, Vasileios; van Rosendael, Philippe J; van der Velde, Enno T; Ajmone Marsan, Nina; Bax, Jeroen J
2017-03-01
Little is known about the association between bicuspid aortic valve (BAV) morphologic findings and the degree of valvular dysfunction, presence of aortopathy, and complications, including aortic valve surgery, aortic dissection, and all-cause mortality. To investigate the association between BAV morphologic findings (raphe vs nonraphe) and the degree of valve dysfunction, presence of aortopathy, and prognosis (including need for aortic valve surgery, aortic dissection, and all-cause mortality). In this large international multicenter registry of patients with BAV treated at tertiary referral centers, 2118 patients with BAV were evaluated. Patients referred for echocardiography from June 1, 1991, through November 31, 2015, were included in the study. Clinical and echocardiographic data were analyzed retrospectively. The morphologic BAV findings were categorized according to the Sievers and Schmidtke classification. Aortic valve function was divided into normal, regurgitation, or stenosis. Patterns of BAV aortopathy included the following: type 1, dilation of the ascending aorta and aortic root; type 2, isolated dilation of the ascending aorta; and type 3, isolated dilation of the sinus of Valsalva and/or sinotubular junction. Association between the presence and location of raphe and the risk of significant (moderate and severe) aortic valve dysfunction and aortic dilation and/or dissection. Of the 2118 patients (mean [SD] age, 47 [18] years; 1525 [72.0%] male), 1881 (88.8%) had BAV with fusion raphe, whereas 237 (11.2%) had BAV without raphe. Bicuspid aortic valves with raphe had a significantly higher prevalence of valve dysfunction, with a significantly higher frequency of aortic regurgitation (622 [33.1%] vs 57 [24.1%], P < .001) and aortic stenosis (728 [38.7%] vs 51 [21.5%], P < .001). Furthermore, aortic valve replacement event rates were significantly higher among patients with BAV with raphe (364 [19.9%] at 1 year, 393 [21.4%] at 2 years, and 447 [24.4%] at 5 years) vs patients without raphe (30 [14.0%] at 1 year, 32 [15.0%] at 2 years, and 40 [18.0%] at 5 years) (P = .02). In addition, the all-cause mortality event rates were significantly higher among patients with BAV with raphe (77 [5.1%] at 1 year, 87 [6.2%] at 2 years, and 110 [9.5%] at 5 years) vs patients without raphe (2 [1.8%] at 1 year, 3 [3.0%] at 2 years, and 5 [4.4%] at 5 years) (P = .03). However, on multivariable analysis, the presence of raphe was not significantly associated with all-cause mortality. In this large multicenter, international BAV registry, the presence of raphe was associated with a higher prevalence of significant aortic stenosis and regurgitation. The presence of raphe was also associated with increased rates of aortic valve and aortic surgery. Although patients with BAV and raphe had higher mortality rates than patients without, the presence of a raphe was not independently associated with increased all-cause mortality.
Barbaro, V; Boccanera, G; Daniele, C; Grigioni, M; Palombo, A
1995-09-01
A fatigue life test, by accelerating the beat rate, simulates several years of virtual life of a prosthetic heart valve in a short period of time. The correlation between the in vivo life of a valve and in vitro testing expectations is as yet not well established, but reproducible test conditions yield precious information about wear and failure. The paper reports a qualitative analysis of mechanical valve wear as part of a comparison program designed to investigate the significance of fatigue testing with the ultimate aim of defining standard guidelines for these type of tests. Two tilting disc valves (29 mm) were subjected to 16 years of fatigue life simulated by means of a Rowan Ash fatigue tester (accelerated rate of 1,200 bpm). Fatigue-induced effects on valve disc and ring surfaces were observed under a monitor microscope to identify wear sites and patterns. A high speed cinematographic system was used to investigate the mechanisms responsible for the wear (wear modes). Valve closure was inspected at a 6,000 frame/s rate. Because of disc rotation during the tilting movement, the points of contact between disc and ring are distributed all around the disc edge but focally on the ring. On both sides of the disc, the surfaces present ring-like concentric grooves. After 16 years of fatigue life the valves showed neither severe wear nor alteration of their fluidodynamic behavior in the pulsatile flow test.
Heart valve replacement with the Sorin tilting-disc prosthesis. A 10-year experience.
Milano, A; Bortolotti, U; Mazzucco, A; Mossuto, E; Testolin, L; Thiene, G; Gallucci, V
1992-02-01
From 1978 to 1988, 697 patients with a mean age of 48 +/- 11 years (range 5 to 75 years) received a Sorin tilting-disc prosthesis; 358 had had aortic valve replacement, 247 mitral valve replacement, and 92 mitral and aortic valve replacement. Operative mortality rates were 7.8%, 11.3%, and 10.8%, respectively, in the three groups. Cumulative duration of follow-up is 1650 patient-years for aortic valve replacement (maximum follow-up 11.4 years), 963 patient-years for mitral valve replacement (maximum follow-up 9.9 years) and 328 patient-years for mitral and aortic valve replacement (maximum follow-up 9.4 years). Actuarial survival at 9 years is 72% +/- 4% after mitral valve replacement, 70% +/- 3% after aortic valve replacement, and 50% +/- 12% after mitral and aortic valve replacement, and actuarial freedom from valve-related deaths is 97% +/- 2% after mitral valve replacement, 92% +/- 2% after aortic valve replacement, and 62% +/- 15% after mitral and aortic valve replacement. Thromboembolic events occurred in 21 patients with aortic valve replacement (1.3% +/- 0.2%/pt-yr), in 12 with mitral valve replacement (1.2% +/- 0.3% pt-yr), and in seven with mitral and aortic valve replacement (2.1% +/- 0.8%), with one case of prosthetic thrombosis in each group; actuarial freedom from thromboembolism at 9 years is 92% +/- 3% after mitral valve replacement, 91% +/- 3% after aortic valve replacement, and 74% +/- 16% after mitral and aortic valve replacement. Anticoagulant-related hemorrhage was observed in 15 patients after aortic valve replacement (0.9% +/- 0.2%/pt-yr), in 9 after mitral valve replacement (0.9% +/- 0.3%/pt-yr), and in 6 with mitral and aortic valve replacement (0.9% +/- 0.5%/pt-yr); actuarial freedom from this complication at 9 years is 94% +/- 2% after aortic valve replacement, 91% +/- 4% after mitral valve replacement, and 68% +/- 16% after mitral and aortic valve replacement. Actuarial freedom from reoperation at 9 years is 97% +/- 2% after mitral and aortic valve replacement, 92% +/- 4% after mitral valve replacement, and 89% +/- 3% after aortic valve replacement, with no cases of mechanical fracture. The Sorin valve has shown a satisfactory long-term overall performance, comparable with other mechanical prostheses, and an excellent durability that renders it a reliable heart valve substitute for the mitral and aortic positions.
The Midterm Outcomes of Bioprosthetic Pulmonary Valve Replacement in Children.
Shinkawa, Takeshi; Lu, Chiajung K; Chipman, Carl; Tang, Xinyu; Gossett, Jeffrey M; Imamura, Michiaki
2015-01-01
The purpose of this study was to assess the outcomes of bioprosthetic pulmonary valve replacement (PVR) in children. This is a retrospective review of all bioprosthetic PVR in children (≤ 20-year old) between 1992 and 2013 at a single institution. Most outcomes studied included pulmonary valve reintervention and bioprosthetic valve function. A total of 136 bioprosthetic PVRs were identified for 123 patients. The median age and body weight at the time of operation were 13.2 years and 48.4 kg. There were 1 early death and 3 late deaths during the median follow-up of 7.2 years (0-22.0 years). The actuarial transplant-free survival was 97.6% at 10 years. There were 43 bioprosthesis reinterventions with 29 reoperations and 14 catheter-based interventions. The freedom from bioprosthesis reintervention was 89.6% and 55.0% at 5 and 10 years, respectively. Echocardiographic bioprosthesis dysfunction (≥ moderate bioprosthesis insufficiency, ≥ 50 mmHg peak gradient through bioprosthesis, or bioprosthesis endocarditis with vegetation) was found in 57 bioprostheses. The freedom from bioprosthesis dysfunction was 74.0% and 32.8% at 5 and 10 years, respectively. Results from the Cox proportional hazards models showed that age had significant association with freedom from bioprosthesis reintervention and freedom from bioprosthesis dysfunction (P < 0.001 and P = 0.03), whereas bioprosthesis type had nonsignificant association with freedom from bioprosthesis dysfunction (P = 0.068). Bioprosthetic PVR in children had excellent early outcomes but rapidly deteriorating midterm outcomes. Careful and close follow-up are necessary for children with bioprosthesis in the pulmonary position. Copyright © 2015 Elsevier Inc. All rights reserved.
Badar, Athar A; Brunton, Alan P T; Mahmood, Ammad H; Dobbin, Stephen; Pozzi, Andrea; McMinn, Jenna F; Sinclair, Andrew J E; Gardner, Roy S; Petrie, Mark C; Curry, Phil A; Al-Attar, Nawwar H K; Pettit, Stephen J
2015-01-01
A systematic search of Medline, EMBASE and CINAHL electronic databases was performed. Original research articles reporting all-cause mortality following surgery in patients with aortic regurgitation and severe left ventricular systolic dysfunction (LVSD) were identified. Nine of the 10 eligible studies were observational, single-center, retrospective analyses. Survival ranged from 86 to 100% at 30 days; 81 to 100% at 1 year and 68 to 84% at 5 years. Three studies described an improvement in mean left ventricular ejection fraction (LVEF) following aortic valve replacement (AVR) of 5-14%; a fourth study reported an increase in mean left ventricular ejection fraction (LVEF) of 9% in patients undergoing isolated AVR but not when AVR was combined with coronary artery bypass graft and/or mitral valve surgery. Three studies demonstrated improvements in functional New York Heart Association (NYHA) class following AVR. Additional studies are needed to clarify the benefits of AVR in patients with more extreme degrees of left ventricular systolic dysfunction (LVSD) and the potential roles of cardiac transplantation and transaortic valve implantation.
Balmforth, Damian; Chacko, Jacob; Uppal, Rakesh
2016-10-01
A best evidence topic was constructed according to a structured protocol. The question addressed was whether (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) aids the diagnosis of prosthetic valve endocarditis (PVE)? A total of 107 publications were found using the reported search, of which 6 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. The reported outcome of all studies was a final diagnosis of confirmed endocarditis on follow-up. All the six studies were non-randomized, single-centre, observational studies and thus represented level 3 evidence. The diagnostic capability of PET/CT for PVE was compared with that of the modified Duke Criteria and echocardiography, and reported in terms of sensitivity, specificity and positive and negative predictive values. All studies demonstrated an increased sensitivity for the diagnosis of PVE when PET/CT was combined with the modified Duke Criteria on admission. A higher SUVmax on PET was found to be significantly associated with a confirmed diagnosis of endocarditis and an additional diagnostic benefit of PET/CT angiography over conventional PET/non-enhanced CT is reported due to improved anatomical resolution. However, PET/CT was found to be unreliable in the early postoperative period due to its inability to distinguish between infection and residual postoperative inflammatory changes. PET/CT was also found to be poor at diagnosing cases of native valve endocarditis. We conclude that PET/CT aids in the diagnosis of PVE when combined with the modified Duke Criteria on admission by increasing the diagnostic sensitivity. The diagnostic ability of PET/CT can be potentiated by the use of PET/CTA; however, its use may be unreliable in the early postoperative period or in native valve endocarditis. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Ribeiro, Henrique B; Le Ven, Florent; Larose, Eric; Dahou, Abdellaziz; Nombela-Franco, Luis; Urena, Marina; Allende, Ricardo; Amat-Santos, Ignacio; Ricapito, Maria de la Paz; Thébault, Christophe; Clavel, Marie-Annick; Delarochelliére, Robert; Doyle, Daniel; Dumont, Eric; Dumesnil, Jean G; Pibarot, Philippe; Rodés-Cabau, Josep
2014-12-01
The transthoracic echocardiographic (TTE) evaluation of the severity of residual aortic regurgitation (AR) following transcatheter aortic valve implantation (TAVI) has been controversial and lacks validation. This study sought to compare TTE and cardiac magnetic resonance (CMR) for assessment of AR in patients undergoing TAVI with a balloon-expandable valve. TTE and CMR exams were performed pre-TAVI in 50 patients and were repeated postprocedure in 42 patients. All imaging data were analysed in centralised core laboratories. The severity of native AR as determined by multiparametric TTE approach correlated well with the regurgitant volume and regurgitant fraction determined by CMR prior to TAVI (Rs=0.79 and 0.80, respectively; p<0.001 for both). However, after TAVI, the correlation between the prosthetic AR severity assessed by TTE and regurgitant volume and fraction measured by CMR was only modest (Rs=0.59 and 0.59, respectively; p<0.001 for both), with an underestimation of AR severity by TTE in 61.9% of patients (1 grade in 59.5%). The TTE jet diameter in parasternal view and the multiparametric approach (Rs=0.62 and 0.59, respectively; both with p<0.001) showed the best correlation with CMR regurgitant fraction post-TAVI. The circumferential extent of prosthetic paravalvular regurgitation showed a poor correlation with CMR regurgitant volume and fraction (Rs=0.32, p=0.084; Rs=0.36, p=0.054, respectively). The severity of AR following TAVI with a balloon-expandable valve was underestimated by echocardiography as compared with CMR. The jet diameter, but not the circumferential extent of the leaks, and the multiparametric echocardiography integrative approach best correlated with CMR findings. These results provide important insight into the evaluation of AR severity post-TAVI. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
NASA Astrophysics Data System (ADS)
Vukicevic, Marija; Conover, Timothy; Zhou, Jian; Hsia, Tain-Yen; Figliola, Richard
2012-11-01
For a child born with only one functional heart ventricle, the sequence of palliative surgeries typically culminates in the Fontan operation. This procedure is usually successful initially, but leads to later complications, for reasons not fully understood. Examples are respiratory-dependent retrograde flows in the caval and hepatic veins, and increased pulmonary vascular resistance (PVR), hypothesized to be responsible for elevated pressure in the liver and disease of the liver and intestines. Here we study the parameters responsible for retrograde flows in the inferior vena cava (IVC) and hepatic vein (HV), and investigate two novel interventions to control retrograde flow: implanting either a Medtronic Contegra valved conduit or an Edwards lifescience pericardial aortic valve in the IVC or HV. We performed the experiments in a multi-scale, patient specific mock circuit, with normal and elevated PVR, towards the optimization of the Fontan circulation. The results show that both valves can significantly reduce retrograde flows in the veins, suggesting potential advantages in the treatment of the patients with congenital heart diseases. Fondation Leducq
Fibrinolytic therapy for mechanical pulmonary valve thrombosis.
Khajali, Zahra; Mohammadzadeh, Shabnam; Maleki, Majid; Peighambari, Mohammad Mehdi; Sadeghpoor, Anita; Ghavidel, Alireza; Elahi, Behrad; Mirzaaghayan, Mohammadreza
2015-01-01
Treatment of prosthetic heart valve thrombosis using intravenous thrombolytics, although an acceptable alternative to surgery, is not complication free, and the literature has a dearth of data on the subject. This study analyzed the results of fibrinolytic treatment (FT) among a single-center group of patients with mechanical pulmonary valve thrombosis. Between 2000 and 2013, 23 consecutive patients with 25 episodes of pulmonary valve thrombosis received FT. The diagnosis of mechanical pulmonary valve thrombosis was established by fluoroscopy and echocardiography. Streptokinase (SK) was used in 24 cases and alteplase in 1 case. The FT was continued a second day for 14 patients (58.3%), a third day for 1 patient, and a fourth day for 1 patient. Echocardiography and fluoroscopy were performed every day until improvement of malfunction was achieved. Of the 23 patients, 19 had complete resolution of hemodynamic abnormalities after FT, 1 had partial resolution, and 2 showed no change. No patient had major complications. Five minor complications were detected, namely, fever, nausea, thrombophlebitis, epistaxi, and pain. Seven patients (30%) experienced recurrence of thrombosis, whereas four patients had surgery (biological pulmonary valve replacement) without re-thrombolytic therapy, one patient was treated with Alteplase, one patient received SK, and one patient received intense anticoagulation using heparin and warfarin. Overall, FT had a success rate of 84%. The results indicate that regardless of the time to pulmonary valve replacement and echocardiographic and fluoroscopic findings, FT was effective in most cases of mechanical pulmonary valve thrombosis. The efficacy increased with second-day thrombolytic therapy. Major complications were not common after lytic therapy for mechanical pulmonary valve thrombosis.
Domitrovic, T Nicholas; Hujer, Andrea M; Perez, Federico; Marshall, Steven H; Hujer, Kristine M; Woc-Colburn, Laila E; Parta, Mark; Bonomo, Robert A
2016-10-01
Background. Successful treatment of infections caused by multidrug-resistant (MDR) Pseudomonas aeruginosa is thwarted by the emergence of antibiotic resistance and biofilm formation on prosthetic devices. Our aims were to decipher the molecular basis of resistance in a unique case of prosthetic valve endocarditis (PVE) caused by MDR P. aeruginosa . Methods. Five sequential MDR P. aeruginosa blood isolates collected during a 7-month period were recovered from a patient suffering from PVE previously exposed to β-lactam antibiotics. Minimum inhibitory concentrations (MICs) of several classes of antibiotics were used to indicate clinical resistance characteristics; relatedness of the isolates was determined using multilocus sequence typing and repetitive sequence-based polymerase chain reaction. Amplification and sequencing of regulatory and resistance genes was performed. Results. All isolates belonged to ST 298, possessed bla PDC-16 , and were resistant to fluoroquinolones and carbapenems. In the course of therapy, we observed a >2-fold increase in cephalosporin resistance (4 µg/mL to >16 µg/mL). Sequencing of the AmpC regulator, amp R, revealed a D135N point mutation in cephalosporin-resistant isolates. Common carbapenemase genes were not identified. All isolates demonstrated a premature stop codon at amino acid 79 of the outer membrane protein OprD and mutations in the quinolone resistance-determining regions of gyr A and par C. Point mutations in nal C, an efflux pump regulator, were also observed. Conclusions. In this analysis, we chart the molecular evolution of β-lactam resistance in a case of PVE. We show that mutations in regulatory genes controlling efflux and cephalosporinase production contributed to the MDR phenotype.
Tran, Christine N; Reichard, Chad A; McMahon, Daniel; Rhee, Audrey
2014-08-01
Anterior urethral valve (AUV) associated with posterior urethral valves (PUVs) is an extremely rare congenital urologic anomaly resulting in lower urinary tract obstruction. We present our experience with 2 children with concomitant AUV and PUV as well as a literature review. The clinical presentation of concomitant AUV and PUV is variable. Successful endoscopic management can result in improvement in renal function, reversal of obstructive changes, and improvement or resolution of voiding dysfunction. Copyright © 2014 Elsevier Inc. All rights reserved.
Actuarial analysis of surgical results: rationale and method.
Grunkemeier, G L; Starr, A
1977-11-01
The use of time-related methods of statistical analysis is essential for valid evaluation of the long-term results of a surgical procedure. Accurate comparison of two procedures or two prosthetic devices is possible only when the length of follow-up is properly accounted for. The purpose of this report is to make the technical aspects of the acturial, or life table, method easily accessible to the surgeon, with emphasis on the motivation for and the rationale behind it. This topic is illustrated in terms of heart valve prostheses, a field that is rapidly developing. Both the authors and readers of articles must be aware that controversies surrounding the relative merits of various prosthetic designs or operative procedures can be settled only if proper time-related methods of analysis are utilized.
Lindman, Brian R; Maniar, Hersh S; Jaber, Wael A; Lerakis, Stamatios; Mack, Michael J; Suri, Rakesh M; Thourani, Vinod H; Babaliaros, Vasilis; Kereiakes, Dean J; Whisenant, Brian; Miller, D Craig; Tuzcu, E Murat; Svensson, Lars G; Xu, Ke; Doshi, Darshan; Leon, Martin B; Zajarias, Alan
2015-04-01
Tricuspid regurgitation (TR) and right ventricular (RV) dysfunction adversely affect outcomes in patients with heart failure or mitral valve disease, but their impact on outcomes in patients with aortic stenosis treated with transcatheter aortic valve replacement has not been well characterized. Among 542 patients with symptomatic aortic stenosis treated in the Placement of Aortic Transcatheter Valves (PARTNER) II trial (inoperable cohort) with a Sapien or Sapien XT valve via a transfemoral approach, baseline TR severity, right atrial and RV size and RV function were evaluated by echocardiography according to established guidelines. One-year mortality was 16.9%, 17.2%, 32.6%, and 61.1% for patients with no/trace (n=167), mild (n=205), moderate (n=117), and severe (n=18) TR, respectively (P<0.001). Increasing severity of RV dysfunction as well as right atrial and RV enlargement were also associated with increased mortality (P<0.001). After multivariable adjustment, severe TR (hazard ratio, 3.20; 95% confidence interval, 1.50-6.82; P=0.003) and moderate TR (hazard ratio, 1.60; 95% confidence interval, 1.02-2.52; P=0.042) remained associated with increased mortality as did right atrial and RV enlargement, but not RV dysfunction. There was an interaction between TR and mitral regurgitation severity (P=0.04); the increased hazard of death associated with moderate/severe TR only occurred in those with no/trace/mild mitral regurgitation. In inoperable patients treated with transcatheter aortic valve replacement, moderate or severe TR and right heart enlargement are independently associated with increased 1-year mortality; however, the association between moderate or severe TR and an increased hazard of death was only found in those with minimal mitral regurgitation at baseline. These findings may improve our assessment of anticipated benefit from transcatheter aortic valve replacement and support the need for future studies on TR and the right heart, including whether concomitant treatment of TR in operable but high-risk patients with aortic stenosis is warranted. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01314313. © 2015 American Heart Association, Inc.
Mladenovic, Zorica; Vranes, Danijela; Obradovic, Slobodan; Dzudovic, Boris; Angelkov Ristic, Andjelka; Ratkovic, Nenad; Jovic, Zoran; Spasic, Marijan; Maric Kocijancic, Jelena; Djruic, Predrag
2018-06-04
Unicuspid aortic valve (UAV) is a rare congenital anomaly of aorta associated with a faster progress of valvular dysfunction, aortic dilatation and with necessity for more frequent controls and precise evaluation Asymptomatic 35 year old man had abnormal systolic diastolic murmur on aortic valve during routine examination. Initial diagnostic with transthoracic echocardiography (TTE) supposed bicuspid aortic valve, while three-dimensional transesophageal echocardiography (3D TEE) and multidetector computed tomography defined unicuspid, unicomissural aortic valve with moderate aortic stenosis and regurgitation. This case report confirmed that 3D TEE gives us opportunity for early, improved and precise diagnosis of UAV. © 2018 Wiley Periodicals, Inc.
Petkar, Hawabibee; Li, Anthony; Bunce, Nicholas; Duffy, Kim; Malnick, Henry; Shah, Jayesh J
2011-03-01
Cellulosimicrobium funkei is a rare, opportunistic pathogen. We describe a case of bacteremia and possibly prosthetic valve endocarditis by this organism in a nonimmunocompromised patient. Useful phenotypic tests for differentiating C. funkei from Cellulosimicrobium cellulans and Cellulosimicrobium terreum include motility, raffinose fermentation, glycogen, D-xylose, and methyl-α-D-glucopyranoside assimilation, and growth at 35°C.
Manjunath, Girish; Rao, Prakash; Prakash, Nagendra; Shivaram, B K
2016-01-01
Recent data from landmark trials suggest that the indications for cardiac pacing and implantable cardioverter defibrillators (ICDs) are set to expand to include heart failure, sleep-disordered breathing, and possibly routine implantation in patients with myocardial infarction and poor ventricular function.[1] This will inevitably result in more patients with cardiac devices undergoing surgeries. Perioperative electromagnetic interference and their potential effects on ICDs pose considerable challenges to the anesthesiologists.[2] We present a case of a patient with automatic ICD with severe left ventricular dysfunction posted for double valve replacement.
Design and Characterization of a Quasi-Passive Pneumatic Foot-Ankle Prosthesis.
Lee, Jeffrey D; Mooney, Luke M; Rouse, Elliott J
2017-07-01
The majority of commercially available passive prosthetic feet are not capable of providing joint mechanics that match that of the intact human ankle. Due to their cantilever design, their stiffness characteristics contrast with what has been observed in the biological ankle, namely, an increase in stiffness during the stance phase of walking. In this paper, we introduce the design and control of a pneumatic foot-ankle prosthesis that attempts to provide biomimetic mechanics. The prosthesis is comprised of a pneumatic cylinder in series with a fiberglass leaf spring, and a solenoid valve to control the flow of air between the two sides of the cylinder. The solenoid valve acts as a mechanical clutch, enabling resetting of the ankle's equilibrium position. By adjusting the pressure inside the cylinder, the prosthesis can be customized to provide a range of ankle mechanics. A mechanical testing machine is used to compare the torque-angle curve of the pneumatic prosthesis with a low-profile passive prosthetic foot. Finally, data are presented of one transtibial amputee walking with the prosthesis at 1.2 m/s. The testing shows that the pneumatic prosthesis is capable of providing an appropriate range of motion as well a maximum torque of 94 Nm, while returning approximately 11.5 J of energy.
Zahoor, Bilal A
2016-08-01
Rhizobium radiobacter, a soil-based organism, is not, usually, pathogenic unless in the immunecompromised. Endocarditis, in the immunocompromised, is a typical presentation generally as a result of catheter-based infections. We describe the presentation of R. radiobacter prosthetic valve endocarditis and the inherent challenges in its presentation and diagnosis. A patient presented with acute limb ischemia secondary to R. radiobacter-mediated endocarditis and subsequent thromboembolization of the distal superior femoral and proximal popliteal arteries in the left lower limb. He underwent an uneventful thrombolectomy that restored blood flow distal to the occlusion and restored the patency of the affected arteries. Postoperatively, the patient maintained several unexplained febrile episodes. Blood cultures remained negative for infection. A cardiac work-up demonstrated the presence of vegetative growth on the prosthetic mitral and native aortic valves. Histopathologic analysis of the extracted thrombus confirmed the presence of R. radiobacter. On further history, it was elucidated that the patient was an intravenous drug user who routinely stored drug paraphernalia in plant beds. The patient recovered uneventfully after Piptazobactam was administered. R. radiobacter, and similarly other soil-based pathogens, should be considered as a potential source of endocarditic infection and thromboembolization in patients who similarly describe a history of intravenous drug use. Copyright © 2016 Elsevier Inc. All rights reserved.
Role of radionuclide imaging for diagnosis of device and prosthetic valve infections
Sarrazin, Jean-François; Philippon, François; Trottier, Mikaël; Tessier, Michel
2016-01-01
Cardiovascular implantable electronic device (CIED) infection and prosthetic valve endocarditis (PVE) remain a diagnostic challenge. Cardiac imaging plays an important role in the diagnosis and management of patients with CIED infection or PVE. Over the past few years, cardiac radionuclide imaging has gained a key role in the diagnosis of these patients, and in assessing the need for surgery, mainly in the most difficult cases. Both 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) and radiolabelled white blood cell single-photon emission computed tomography/computed tomography (WBC SPECT/CT) have been studied in these situations. In their 2015 guidelines for the management of infective endocarditis, the European Society of Cardiology incorporated cardiac nuclear imaging as part of their diagnostic algorithm for PVE, but not CIED infection since the data were judged insufficient at the moment. This article reviews the actual knowledge and recent studies on the use of 18F-FDG PET/CT and WBC SPECT/CT in the context of CIED infection and PVE, and describes the technical aspects of cardiac radionuclide imaging. It also discusses their accepted and potential indications for the diagnosis and management of CIED infection and PVE, the limitations of these tests, and potential areas of future research. PMID:27721936
Oda, Takeshi; Kato, Seiya; Tayama, Eiki; Fukunaga, Shuji; Akashi, Hidetoshi; Aoyagi, Shigeaki
2009-01-01
A Carpentier-Edwards pericardial (CEP) bioprosthesis was explanted from an 81-year-old woman due to nonstructural dysfunction 9 years after mitral valve replacement. The nonstructural dysfunction produced severe regurgitation in the mitral position. During the surgery, excessive pannus overgrowth was seen on the left ventricular side of the CEP bioprosthesis. Pannus overgrowth was prominent on one leaflet. That leaflet was stiff and shortened due to the excessive overgrowth of pannus. In this patient, the distortion of one leaflet was the main reason for transvalvular leakage of the CEP bioprosthesis in the mitral position. A new CEP bioprosthesis was implanted in the mitral position. Pathological analysis revealed fibrotic pannus with a small amount of cellular material over the leaflets of the resected CEP valve. This change was marked on the distorted leaflet.
Infective endocarditis in the transesophageal echocardiographic era.
Hwang, J J; Shyu, K G; Chen, J J; Ko, Y L; Lin, J L; Tseng, Y Z; Kuan, P; Lien, W P
1993-01-01
During a 45-month period, 50 consecutive patients with infective endocarditis were evaluated at the National Taiwan University Hospital with emphasis on the role of transesophageal echocardiography (TEE) in the management of these patients. Among them, rheumatic heart disease was still the most common underlying cardiac disorder (10/50, 20%), while mitral valve prolapse (8/50, 16%) and congenital heart disease (8/50, 16%) were also frequently encountered. More than one third (19/50, 38%) had no underlying heart disease. Four intravenous drug abusers, quite rare previously in Taiwan, were found during the study period. Native valves involved were mostly mitral valve (n = 18), aortic valve (n = 15), and both mitral and aortic valves (n = 3). Tricuspid valve and pulmonic valve were involved in 3 and 2 patients, respectively. Streptococcus viridans was the leading microorganism isolated (21/50, 42%). Staphylococci and enterococci were found in 9 (18%) and 5 (10%) patients, respectively. Twelve patients (24%) were culture-negative in this series. Embolic complications occurred in 13 patients (26%), with a total of 17 episodes. No significant correlation was found between the occurrence of embolization and the vegetation size or the location of the vegetation, if patients with right-sided valvular vegetation and no identifiable vegetation were excluded. Surgery was needed by 25 patients (50%), and mortality occurred in 6 (12%). TEE was superior to transthoracic echocardiography in the detection of vegetations at the mitral or prosthetic valves. Concerning the associated complications with infective endocarditis, TEE was also superior in estimating the severity of mitral regurgitation, recognizing ruptured chordae tendineae and detecting subaortic complications such as valve ring abscess and mitral valve perforation.(ABSTRACT TRUNCATED AT 250 WORDS)
Coronary flow reserve is impaired in patients with aortic valve calcification.
Bozbas, Huseyin; Pirat, Bahar; Yildirir, Aylin; Simşek, Vahide; Sade, Elif; Eroglu, Serpil; Atar, Ilyas; Altin, Cihan; Demirtas, Saadet; Ozin, Bulent; Muderrisoglu, Haldun
2008-04-01
Calcific aortic valve disease is an active and progressive condition. Data indicate that aortic valve calcification (AVC) is associated with endothelial dysfunction and accepted as a manifestation of atherosclerosis. Coronary flow reserve (CFR) determined by transthoracic echocardiography has been introduced as a reliable indicator for coronary microvascular function. In this study we aimed to evaluate CFR in patients with AVC. Eighty patients, aged more than 60 years, without coronary heart disease or diabetes mellitus were included: 40 had AVC without significant stenosis (peak gradient across the valve <25 mm Hg) and 40 had normal aortic valves (controls). Using transthoracic Doppler echocardiography, we measured coronary diastolic peak flow velocities (PFV) at baseline and after dipyridamole infusion. CFR was calculated as the ratio of hyperemic to baseline diastolic PFV and was compared between groups. Mean ages for patients with AVC and controls were 68.9+/-6.2 and 67.6+/-5.9 years (P=.3). There were no significant differences regarding clinical characteristics, laboratory findings, ejection fraction, or peak aortic valve gradients. Mean diastolic PFV at baseline and during hyperemia were 28.4+/-4.2 and 59.2+/-7.8 cm/s for AVC and 27.7+/-3.9 and 68.5+/-10.5 cm/s for controls. Compared with controls, patients with AVC had significantly lower CFR values (2.12+/-0.41 versus 2.51+/-0.51; P<.0001). CFR is impaired in patients with AVC before valve stenosis develops, suggesting that microvascular-endothelial dysfunction is present during the early stages of the calcific aortic valve disease.
Anthropomorphic cardiac ultrasound phantom.
Smith, S W; Rinaldi, J E
1989-10-01
A new phantom is described which simulates the human cardiac anatomy for applications in ultrasound imaging, ultrasound Doppler, and color-flow Doppler imaging. The phantom consists of a polymer left ventricle which includes a prosthetic mitral and aortic valve and is connected to a mock circulatory loop. Aerated tap water serves as a blood simulating fluid and ultrasound contrast medium within the circulatory loop. The left ventricle is housed in a Lexan ultrasound visualization chamber which includes ultrasound viewing ports and acoustic absorbers. A piston pump connected to the visualization chamber by a single port pumps degassed water within the chamber which in turn pumps the left ventricle. Real-time ultrasound images and Doppler studies measure flow patterns through the valves and within the left ventricle.
Simulation of blood flow through an artificial heart
NASA Technical Reports Server (NTRS)
Kiris, Cetin; Chang, I-Dee; Rogers, Stuart E.; Kwak, Dochan
1991-01-01
A numerical simulation of the incompressible viscous flow through a prosthetic tilting disk heart valve is presented in order to demonstrate the current capability to model unsteady flows with moving boundaries. Both steady state and unsteady flow calculations are done by solving the incompressible Navier-Stokes equations in 3-D generalized curvilinear coordinates. In order to handle the moving boundary problems, the chimera grid embedding scheme which decomposes a complex computational domain into several simple subdomains is used. An algebraic turbulence model for internal flows is incorporated to reach the physiological values of Reynolds number. Good agreement is obtained between the numerical results and experimental measurements. It is found that the tilting disk valve causes large regions of separated flow, and regions of high shear.
Wilson, Carole L; Gough, Peter J; Chang, Cindy A; Chan, Christina K; Frey, Jeremy M; Liu, Yonggang; Braun, Kathleen R; Chin, Michael T; Wight, Thomas N; Raines, Elaine W
2013-01-01
Global inactivation of the metalloproteinase ADAM17 during mouse development results in perinatal lethality and abnormalities of the heart, including late embryonic cardiomegaly and thickened semilunar and atrioventricular valves. These defects have been attributed in part to a lack of ADAM17-mediated processing of HB-EGF, as absence of soluble HB-EGF results in similar phenotypes. Because valvular mesenchymal cells are largely derived from cardiac endothelial cells, we generated mice with a floxed Adam17 allele and crossed these animals with Tie2-Cre transgenics to focus on the role of endothelial ADAM17 in valvulogenesis. We find that although hearts from late-stage embryos with ablation of endothelial ADAM17 appear normal, an increase in valve size and cell number is evident, but only in the semilunar cusps. Unlike Hbegf(-/-) valves, ADAM17-null semilunar valves do not differ from controls in acute cell proliferation at embryonic day 14.5 (E14.5), suggesting compensatory processing of HB-EGF. However, levels of the proteoglycan versican are significantly reduced in mutant hearts early in valve remodeling (E12.5). After birth, aortic valve cusps from mutants are not only hyperplastic but also show expansion of the glycosaminoglycan-rich component, with the majority of adults exhibiting aberrant compartmentalization of versican and increased deposition of collagen. The inability of mutant outflow valve precursors to transition into fully mature cusps is associated with decreased postnatal viability, progressive cardiomegaly, and systolic dysfunction. Together, our data indicate that ADAM17 is required in valvular endothelial cells for regulating cell content as well as extracellular matrix composition and organization in semilunar valve remodeling and homeostasis. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Boudjemline, Younes
2018-01-01
To describe a new modification, the one-step procedure, that allows interventionists to pre-stent and implant a Melody valve simultaneously. Percutaneous pulmonary valve implantation (PPVI) is the standard of care for managing patients with dysfunctional right ventricular outflow tract, and the approach is standardized. Patients undergoing PPVI using the one-step procedure were identified in our database. Procedural data and radiation exposure were compared to those in a matched group of patients who underwent PPVI using the conventional two-step procedure. Between January 2016 and January 2017, PPVI was performed in 27 patients (median age/range, 19.1/10-55 years) using the one-step procedure involving manual crimping of one to three bare metal stents over the Melody valve. The stent and Melody valve were delivered successfully using the Ensemble delivery system. No complications occurred. All patients had excellent hemodynamic results (median/range post-PPVI right ventricular to pulmonary artery gradient, 9/0-20 mmHg). Valve function was excellent. Median procedural and fluoroscopic times were 56 and 10.2 min, respectively, which significantly differed from those of the two-step procedure group. Similarly, the dose area product (DAP), and radiation time were statistically lower in the one-step group than in the two-step group (P < 0.001 for all variables). After a median follow-up of 8 months (range, 3-14.7), no patient underwent reintervention, and no device dysfunction was observed. The one-step procedure is a safe modification that allows interventionists to prestent and implants the Melody valve simultaneously. It significantly reduces procedural and fluoroscopic times, and radiation exposure. © 2017 Wiley Periodicals, Inc.
Narang, Nikhil; Lang, Roberto M; Liarski, Vladimir M; Jeevanandam, Valluvan; Hofmann Bowman, Marion A
2017-01-01
A 55-year-old man with a history of erosive, seropositive rheumatoid arthritis (RA), and interstitial lung disease presented with shortness of breath. Echocardiography showed new-onset severe left ventricular (LV) dysfunction with an ejection fraction (EF) of 15% and moderately increased mean aortic valve gradient of 20 mmHg in a trileaflet aortic valve with severe sclero-calcific degeneration. Coronary angiography revealed no significant obstructive coronary disease. Invasive hemodynamic studies and dobutamine stress echocardiography were consistent with moderate aortic stenosis. Guideline directed medical therapy for heart failure with reduced EF was initiated; however, diuretics and neurohormonal blockade (beta-blocker and angiotensin receptor blocker) provided minimal improvement, and the patient remained functionally limited. Of interest, echocardiography performed 1 year prior to his presentation showed normal LV EF and mild aortic leaflet calcification with moderate stenosis, suggesting a rapid progressing of calcific aortic valve disease. Subsequently, the patient underwent surgical aortic valve replacement and demonstrated excellent postsurgical recovery of LV EF (55%). Calcific aortic valve disease is commonly associated with aging, bicuspid aortic valve, and chronic kidney disease. Pathophysiological mechanism for valvular calcification is incompletely understood but include osteogenic transformation of valvular interstitial cells mediated by local and systemic inflammatory processes. Several rheumatologic diseases including RA are associated with premature atherosclerosis and arterial calcification, and we speculated a similar role of RA accelerating calcific aortic valve disease. We present a case of accelerated aortic valve calcification with (only) moderate stenosis, complicated by a rapid decline in LV systolic performance. Guidelines for AVR in moderate stenosis without concomitant cardiac surgery are not well established, although it should be considered in selected patients.
Sponga, Sandro; Mazzaro, Enzo; Bagur, Rodrigo; Livi, Ugolino
2017-04-01
A 40-year-old man underwent 4 aortic surgeries because of endocarditis and subsequent prosthesis dehiscence. At the last recurrence he presented with acute severe aortic regurgitation of a Pericarbon Freedom (LivaNova plc, London, UK) stentless bioprosthesis and a morphologically disarranged aortic root. He also presented with left ventricular dysfunction and a very low origin of the left coronary artery. Therefore, a fifth redo aortic valve replacement was considered at high surgical risk. Accordingly, before listing the patient for a heart transplantation, a transcatheter valve-in-valve implantation with the JenaValve (JenaValve Technology, GmbH, Munich, Germany) prosthesis was performed. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Early calcification of the aortic Mitroflow pericardial bioprosthesis in the elderly.
Alvarez, Jose Rubio; Sierra, Juan; Vega, Marino; Adrio, Belen; Martinez-Comendador, Jose; Gude, Francisco; Martinez-Cereijo, Jose; Garcia, Javier
2009-11-01
We report our experience in the elderly with aortic valve replacement using the Mitroflow A12 pericardial bioprosthesis. From January 1993 to January 2006, 491 patients over the age of 70 years received an aortic Mitroflow A12 bioprosthesis implantation. Concomitant procedures included coronary artery bypass grafting in 20% of patients. All patients had routine postoperative Echo-Doppler studies at discharge, one month and a mean of 11.1 months after surgery and annually thereafter. Twenty (4%) patients underwent a second aortic valve replacement due to bioprosthetic valve dysfunction (Group 2). Calcified stenosis was the most common finding at reoperation (98%). Median time to valve reoperation was 76 months. Of patients requiring reoperation, median age at first and second implantation was 73 (70-78) and 79 (76-83) years, respectively. For all patients, freedom from structural valve dysfunction (SVD) was 95+/-3% at 5 years and 55.8+/-2% at 10 years. Bioprosthetic valve deterioration was identified in 27 patients (Group 1). Median age of these patients at first operation and at diagnosis of deterioration by echo was 75 (70-84) and 77 (70-82) years, respectively. The median interval between operation and detection of bioprosthesis valve deterioration was 46 months. Among the total patient population, freedom from bioprosthetic deterioration was 85.7+/-2% at 5 years and 33.5+/-4% at 10 years. The Mitroflow A12 pericardial bioprosthesis provides less than optimal performance in elderly patients.
Penile prosthetic surgery for the management of Peyronie’s disease
Raheem, Omer A.
2017-01-01
With the increased prevalence of Peyronie’s disease (PD) among men, there is also an up-rise of associated erectile dysfunction (ED) which can be devastating psychologically and sexually to most men. A wide range of therapies including medical and surgical procedures are available to satisfactorily address this condition. However when ED coexists, the gold standard treatment is penile prosthetic prosthesis (PP) with or without additional straightening procedures. We herein systematically review the contemporary literature addressing the role of the PP in the management of PD with concomitant ED with particular emphasis on patient’s satisfaction, outcomes and safety. PMID:29238661
Left ventricular assist device malfunction: a systematic approach to diagnosis.
Horton, Steven C; Khodaverdian, Reza; Powers, Amanda; Revenaugh, James; Renlund, Dale G; Moore, Stephanie A; Rasmusson, Brad; Nelson, Karl E; Long, James W
2004-05-05
A protocol was designed to diagnose the common malfunctions of a left ventricular assist device (LVAD). Mechanical circulatory support, primarily with an LVAD, is increasingly used for treatment of advanced heart failure (HF). Left ventricular assist device dysfunction is a recognized complication; but heretofore, a systematic method to accurately diagnose LVAD dysfunction has not been thoroughly described. We developed a catheter-based protocol designed to characterize a normally functioning LVAD and diagnose multiple types of dysfunction. A total of 15 studies of 10 patients supported with an LVAD were reviewed. All patients had been evaluated due to concerns regarding LVAD dysfunction. Of 15 examinations performed, 11 documented severe LVAD inflow valve regurgitation. One of these cases proved to have coexistent severe mitral valve regurgitation. One case was diagnosed with distortion of the LVAD outflow graft. One case of suspected embolization from the pumping chamber excluded the outflow graft as the source of emboli. One study had aortic insufficiency. As LVAD use for treatment of end-stage HF becomes widespread and durations of support are extended, dysfunction will be increasingly prevalent. This catheter-based protocol provided a practical method to diagnose multiple causes of LVAD dysfunction.
Pockett, C R; Moore, J W; El-Said, H G
2017-02-01
Adverse events from Melody valve implantation may be catastrophic. To date a role for three dimensional rotational angiography of the aortic root (3DRAA) during Melody valve implantation has not been established. To describe the role of 3DRAA in the assessment of Melody valve candidacy and to demonstrate that it may improve outcomes. All patients who underwent cardiac catheterisation for Melody valve implantation and 3DRAA between August 2013 and February 2015 were reviewed. 31 patients had 3DRAA with balloon sizing. Ten were deemed not Melody candidates (5 coronary compression, 2 aortic root distortion with cusp flattening, 2 RVOT was too large, and 1 had complex branch stenosis and a short landing zone). Of the 21 patients who were Melody candidates, 12 had conduits, 6 prosthetic valves and 3 native RVOTs. In patients with conduits, the technique of stenting the conduit prior to dilation was used after measuring the distance between the conduit and the coronary arteries on 3DRAA. In the Melody patients, we had 100% procedural success and no serious adverse events (coronary compression, tears, stent fracture or endocarditis). As a tool for case selection, 3DRAA may facilitate higher procedural success and decreased risk of serious adverse events. Furthermore, 3D rotational angiography allows stenting of the conduit prior to dilation, which may prevent tears and possibly endocarditis.
Aortic valve replacement using continuous suture technique in patients with aortic valve disease.
Choi, Jong Bum; Kim, Jong Hun; Park, Hyun Kyu; Kim, Kyung Hwa; Kim, Min Ho; Kuh, Ja Hong; Jo, Jung Ku
2013-08-01
The continuous suture (CS) technique has several advantages as a method for simple, fast, and secure aortic valve replacement (AVR). We used a simple CS technique without the use of a pledget for AVR and evaluated the surgical outcomes. Between October 2007 and 2012, 123 patients with aortic valve disease underwent AVR alone (n=28) or with other concomitant cardiac procedures (n=95), such as mitral, tricuspid, or aortic surgery. The patients were divided into two groups: the interrupted suture (IS) group (n=47), in which the conventional IS technique was used, and the CS group (n=76), in which the simple CS technique was used. There were two hospital deaths (1.6%), which were not related to the suture technique. There were no significant differences in cardiopulmonary bypass time or aortic cross-clamp time between the two groups for AVR alone or AVR with concomitant cardiac procedures. In the IS group, two patients had prosthetic endocarditis and one patient experienced significant perivalvular leak. These patients underwent reoperations. In the CS group, there were no complications related to the surgery. Postoperatively, the two groups had similar aortic valve gradients. The simple CS method is useful and secure for AVR in patients with aortic valve disease, and it may minimize surgical complications, as neither pledgets nor braided sutures are used.
Risk Factors for Prosthetic Pulmonary Valve Failure in Patients With Congenital Heart Disease.
Oliver, Jose Maria; Garcia-Hamilton, Diego; Gonzalez, Ana Elvira; Ruiz-Cantador, Jose; Sanchez-Recalde, Angel; Polo, Maria Luz; Aroca, Angel
2015-10-15
The incidence and risk factors for prosthetic pulmonary valve failure (PPVF) should be considered when determining optimal timing for pulmonary valve replacement (PVR) in asymptomatic patients with congenital heart disease (CHD). The cumulative freedom for reintervention due to PPVF after 146 PVR in 114 patients with CHD was analyzed. Six potential risk factors (underlying cardiac defect, history of palliative procedures, number of previous cardiac interventions, hemodynamic indication for PVR, type of intervention, and age at intervention) were analyzed using Cox proportional hazard modeling. Receiver operating characteristic (ROC) curves were used for discrimination. Internal validation in patients with tetralogy of Fallot was also performed. Median age at intervention was 23 years. There were 60 reinterventions due to PPVF (41%). Median event-free survival was 14 years (95% confidence interval [CI] 12 to 16 years). The only independent risk factor was the age at intervention (hazard ratio [HR] 0.93, 95% CI 0.90 to 0.97; p = 0.001; area under the ROC curve 0.95, 95% CI 0.92 to 0.98; p <0.001). The best cut-off point was 20.5 years. Freedom from reintervention for PPVF 15 years after surgery was 70% when it was performed at age >20.5 years compared with 33% when age at intervention was <20.5 years (p = 0.004). Internal validation in 102 PVR in patient cohort with tetralogy of Fallot (ROC area 0.98, 95% CI 0.96 to 1.0; p <0.001) was excellent. In conclusion, age at intervention is the main risk factor of reintervention for PPVF. The risk of reintervention is 2-fold when PVR is performed before the age of 20.5 years. Copyright © 2015 Elsevier Inc. All rights reserved.
Scriven, James E; Scobie, Antonia; Verlander, Neville Q; Houston, Angela; Collyns, Tim; Cajic, Vjeran; Kon, Onn Min; Mitchell, Tamara; Rahama, Omar; Robinson, Amy; Withama, Shirmila; Wilson, Peter; Maxwell, David; Agranoff, Daniel; Davies, Eleri; Llewelyn, Meirion; Soo, Shiu-Shing; Sahota, Amandip; Cooper, Mike; Hunter, Michael; Tomlins, Jennifer; Tiberi, Simon; Kendall, Simon; Dedicoat, Martin; Alexander, Eliza; Fenech, Teresa; Zambon, Maria; Lamagni, Theresa; Smith, E Grace; Chand, Meera
2018-05-24
Mycobacterium chimaera infection following cardiac surgery, due to contaminated cardiopulmonary bypass heater-cooler units, has been reported worldwide. However, the spectrum of clinical disease remains poorly understood. To address this, we report the clinical and laboratory features, treatment and outcome of the first 30 UK cases. Case note review was performed for cases identified retrospectively through outbreak investigations and prospectively through on-going surveillance. Case definition was Mycobacterium chimaera detected in any clinical specimen, history of cardiothoracic surgery with cardiopulmonary bypass, and compatible clinical presentation. Thirty patients were identified (28 with prosthetic material) exhibiting a spectrum of disease including prosthetic valve endocarditis (14/30), sternal wound infection (2/30), aortic graft infection (4/30), and disseminated (non-cardiac) disease (10/30). Patients presented a median of 14 months post surgery (maximum 5 years) most commonly complaining of fever and weight loss. Investigations frequently revealed lymphopenia, thrombocytopenia, liver cholestasis and non-necrotising granulomatous inflammation. Diagnostic sensitivity for a single mycobacterial blood culture was 68% but increased if multiple samples were sent. 27 patients started macrolide-based combination treatment and 14 had further surgery. To date, 18 patients have died (60%) a median of 30 months (IQR 20-39) after initial surgery. Survival analysis identified younger age, mitral valve surgery, mechanical valve replacement, higher serum sodium concentration and lower CRP as factors associated with better survival. Mycobacterium chimaera infection following cardiac surgery is associated with a wide spectrum of disease. The diagnosis should be considered in all patients who develop an unexplained illness following cardiac surgery. Copyright © 2018. Published by Elsevier Ltd.
López, Javier; Revilla, Ana; Vilacosta, Isidre; Villacorta, Eduardo; González-Juanatey, Carlos; Gómez, Itziar; Rollán, María Jesús; San Román, José Alberto
2007-03-01
There is no agreement in the best cutoff time to distinguish between early- and late- onset prosthetic valve endocarditis (PVE). Our objectives are to define early-onset PVE according to the microbiological spectrum and to analyse the profile and short-term prognosis of this entity. The microbiological profile of 172 non-drug users, who were patients with PVE, were compared according to the time elapsed from surgery among 640 endocarditis diagnosed between 1996 and 2004. There were no differences in the microbiological profile of patients with PVE occurred within 2 months of valve replacement and those accounting between 2 and 12 months. The proportion of coagulase-negative Staphylococci (CNS) was higher during the first year post-intervention (37 vs. 18%, P = 0.005) and Streptococci viridans were more common after 1 year (18 vs. 1%, P = 0.001). The percentage of methicilin-resistant CNS strains was higher before 1 year (77 vs. 30%, P = 0.004). Early-onset PVE represented 38% of all episodes of PVE, CNS being the most frequent isolated microorganisms (37%), most of them methicilin resistant (77%). In-hospital mortality of patients who needed urgent surgery was 46% and elective surgery 25%. Overall, in-hospital mortality was 38% and no differences were seen between surgical and medical groups (32 vs. 45%, P = 0.30). Periannular complications were associated with higher in-hospital mortality (60 vs. 27%, P = 0.007). According to the microbiological profile, the most appropriate cutoff time to distinguish between early- and late-onset PVE was 1 year. Methicilin-resistant CNS are the most frequent pathogens and periannular complications, the only risk factor for in-hospital mortality.
Eustachian Valve Endocarditis: Echocardiographic Diagnosis in a Critical Care Patient.
Alves, Mariana; Faria, Rita; Messias, António; Meneses-Oliveira, Carlos
2018-01-01
Eustachian valve endocarditis is rare. A literature review revealed that only 29 cases have been reported and, among them, there is only one mention of an intensive care unit (ICU) admission. We present an 82-year-old man without previous medical records who presented with septic shock with multiple organ dysfunction. The patient was admitted to the ICU and deteriorated with combined shock (septic + cardiogenic). A second ultrasound screen detected a prominent Eustachian valve with mobile multilobulated vegetation attached. Transesophageal echocardiography confirmed a 12 mm oscillating mass attached to a visible Eustachian valve.
Current Management of Calcific Aortic Stenosis
Lindman, Brian R.; Bonow, Robert O.; Otto, Catherine M.
2014-01-01
Calcific aortic stenosis (AS) is a progressive disease with no effective medical therapy that ultimately requires aortic valve replacement (AVR) for severe valve obstruction. Echocardiography is the primary diagnostic approach to define valve anatomy, measure AS severity and evaluate the left ventricular (LV) response to chronic pressure overload. In asymptomatic patients, markers of disease progression include the degree of leaflet calcification, hemodynamic severity of stenosis, adverse LV remodeling, reduced LV longitudinal strain, myocardial fibrosis and pulmonary hypertension. The onset of symptoms portends a predictably high mortality rate unless AVR is performed. In symptomatic patients, AVR improves symptoms, improves survival and, in patients with LV dysfunction, improves systolic function. Poor outcomes after AVR are associated with low-flow low-gradient AS, severe ventricular fibrosis, oxygen dependent lung disease, frailty, advanced renal dysfunction and a high comorbidity score. However, in most patients with severe symptoms, AVR is lifesaving. Bioprosthetic valves are recommended for patients over the age of 65 years. Transcatheter AVR is now available for patients with severe comorbidities, is recommended in patients who are deemed inoperable and is a reasonable alternative to surgical AVR in high risk patients. PMID:23833296
NASA Technical Reports Server (NTRS)
Pereira, Jeremy J.; Lauer, Michael S.; Bashir, Mohammad; Afridi, Imran; Blackstone, Eugene H.; Stewart, William J.; McCarthy, Patrick M.; Thomas, James D.; Asher, Craig R.
2002-01-01
OBJECTIVE: We sought to assess whether aortic valve replacement (AVR) among patients with severe aortic stenosis (AS), severe left ventricular (LV) dysfunction and a low transvalvular gradient (TVG) is associated with improved survival. BACKGROUND: The optimal management of patients with severe AS with severe LV dysfunction and a low TVG remains controversial. METHODS: Between 1990 and 1998, we evaluated 68 patients who underwent AVR at our institution (AVR group) and 89 patients who did not undergo AVR (control group), with an aortic valve area < or = 0.75 cm(2), LV ejection fraction < or = 35% and mean gradient < or = 30 mm Hg. Using propensity analysis, survival was compared between a cohort of 39 patients in the AVR group and 56 patients in the control group. RESULTS: Despite well-matched baseline characteristics among propensity-matched patients, the one- and four-year survival rates were markedly improved in patients in the AVR group (82% and 78%), as compared with patients in the control group (41% and 15%; p < 0.0001). By multivariable analysis, the main predictor of improved survival was AVR (adjusted risk ratio 0.19, 95% confidence interval 0.09 to 0.39; p < 0.0001). The only other predictors of mortality were age and the serum creatinine level. CONCLUSIONS: Among select patients with severe AS, severe LV dysfunction and a low TVG, AVR was associated with significantly improved survival.
Thermomechanical Cycling Investigation of Cu and Niti Reinforced Lead-Free Solder
2006-09-01
hold fractured bones together during the healing process. The SMA plates have proven to perform well. The shape memory effect places the bones in...taking this a step further and developing robot prosthetic devices using SMA technology [27]. Other uses of SMA’s include hydraulic connections...glasses frames, bra underwires, fire safety valves , etc. [18]. In each case the attributes of the different alloys must be weighed to determine proper
In-line pressure-flow module for in vitro modelling of haemodynamics and biosensor validation
NASA Technical Reports Server (NTRS)
Koenig, S. C.; Schaub, J. D.; Ewert, D. L.; Swope, R. D.; Convertino, V. A. (Principal Investigator)
1997-01-01
An in-line pressure-flow module for in vitro modelling of haemodynamics and biosensor validation has been developed. Studies show that good accuracy can be achieved in the measurement of pressure and of flow, in steady and pulstile flow systems. The model can be used for development, testing and evaluation of cardiovascular-mechanical-electrical anlogue models, cardiovascular prosthetics (i.e. valves, vascular grafts) and pressure and flow biosensors.
Omar, R Z; Morton, L S; Beirne, M; Blot, W J; Lawford, P V; Hose, R; Taylor, K M
2001-06-01
Björk-Shiley 60 degrees convexo-concave prosthetic heart valves (Shiley, Inc, Irvine, Calif, a subsidiary of Pfizer, Inc) continue to be a concern for approximately 35,000 nonexplanted patients worldwide, with approximately 600 events reported to the manufacturer to date. Fractures of the outlet struts of the valves began to appear in the early 1980s and have continued to the present, but their causes are only partially understood. A matched case-control study was conducted evaluating manufacturing records for 52 valves with outlet strut fractures and 248 control subjects matched for age at implantation, valve size, and valve position. In addition to the risk factors recognized as determinants of outlet strut fracture, the United Kingdom case-control study has observed 7- to 9-fold increased risk with performance of multiple hook deflection tests. This test was performed more than once, usually after rework on the valve. Six valves in this study underwent multiple hook deflection tests, of which 4 experienced an outlet strut fracture. Cracks and further rework were noted for these valves. Significant associations were also observed between outlet strut fracture and disc-to-strut gap measurements taken before the attachment of the sewing ring. It is our view that a combination of factors related to valve design, manufacturing process, and patient characteristics are responsible for outlet strut fractures of Björk-Shiley convexo-concave valves. Multiple hook deflection tests have emerged as a potential new risk factor for outlet strut fracture in both The Netherlands and the United Kingdom. This factor appears to be correlated with the presence of other abnormalities. A further study is needed to investigate the factors correlated with multiple hook deflection tests. On confirmation of risk, the presence of multiple hook deflection tests may be added to equations, quantifying the risk of outlet strut fracture for comparison against risk of mortality and serious morbidity from explant operations.
Xu, Jia-Rui; Zhuang, Ya-Min; Liu, Lan; Shen, Bo; Wang, Yi-Mei; Luo, Zhe; Teng, Jie; Wang, Chun-Sheng; Ding, Xiao-Qiang
2017-01-01
Objective To evaluate the impact of the renal dysfunction (RD) type and change of postoperative cardiac function on the risk of developing acute kidney injury (AKI) in patients who underwent cardiac valve surgery. Method Reversible renal dysfunction (RRD) was defined as preoperative RD in patients who had not been initially diagnosed with chronic kidney disease (CKD). Cardiac function improvement (CFI) was defined as postoperative left ventricular ejection function – preoperative left ventricular ejection function (ΔEF) >0%, and cardiac function not improved (CFNI) as ΔEF ≤0%. Results Of the 4,805 (94%) cardiac valve surgery patients, 301 (6%) were RD cases. The AKI incidence in the RRD group (n=252) was significantly lower than in the CKD group (n=49) (36.5% vs 63.3%, P=0.018). The AKI and renal replacement therapy incidences in the CFI group (n=174) were significantly lower than in the CFNI group (n=127) (33.9% vs 50.4%, P=0.004; 6.3% vs 13.4%, P=0.037). After adjustment for age, gender, and other confounding factors, CKD and CKD + CFNI were identified as independent risk factors for AKI in all patients after cardiac valve surgery. Multivariate logistic regression analysis showed that the risk factors for postoperative AKI in preoperative RD patients were age, gender (male), hypertension, diabetes, chronic heart failure, cardiopulmonary bypass time (every 1 min added), and intraoperative hypotension, while CFI after surgery could reduce the risk. Conclusion For cardiac valve surgery patients, preoperative CKD was an independent risk factor for postoperative AKI, but RRD did not add to the risk. Improved postoperative cardiac function can significantly reduce the risk of postoperative AKI. PMID:29184415
Cardiac valve evaluation and adipokine levels in obese women treated with sibutramine.
Saraç, Sefa; Saraç, Fulden
2010-06-01
The aims of present study were 1) to evaluate cardiac valve characteristics, 2) to determine the plasma concentrations of fibrinogen, high sensitivity C-reactive protein (hsCRP), adiponectin, and tumor necrosis factor-alpha (TNF-alpha) in the obese women before and after 19 months sibutramine treatment in the obese women. Sixty obese women were enrolled in this prospective, randomized study. Thirty women received 10 mg once daily dose of sibutramine for 19 months. The rest of the obese women received 15 mg once daily dose of sibutramine for 19 months. All patients were evaluated with echocardiography. Plasma levels of adiponectin and TNF-alpha were measured by enzyme-linked immunosorbent assay (ELISA) and hsCRP by immunoturbimetric assay. Student paired and unpaired t tests were used to compare the 10 mg or 15 mg dose sibutramine effects either in groups or between the groups. There were no signs of significant regurgitation or thickening of the mitral and aortic valves on echocardiographic evaluation performed after 19 months of treatment. Parameters of systolic function after 10 or 15 mg treatment were not different from pretreatment characteristics. Minimal tricuspid regurgitation was found in one (1/27) patient treated with 10 mg sibutramine after 19 months. Among obese patients treated with 15 mg sibutramine one patient (1/28) had minimal mitral valve regurgitation and 2 patients (2/28) had minimal aortic insufficiency. Stage II diastolic dysfunction in the 15 obese treated with 15 mg regressed to stage I diastolic dysfunction (50%). Stage II diastolic dysfunction in the 10 obese treated with 10 mg regressed to stage I diastolic dysfunction (33.3%). Mean levels of TNF-alpha(p=0.04), fibrinogen (p=0.03) and hsCRP (p=0.04)i decreased and adiponectin (p=0.03) levels increased in the obese treated with 10 mg sibutramine. Likewise, in the patients treated with 15 mg sibutramine, mean levels of TNF- alpha(p=0.01), fibrinogen (p= 0.02), and hsCRP (p= 0.04) decreased and adiponectin (p= 0.02) levels increased. Nineteen months of sibutramine treatment does not affect heart valve and systolic functions, however, diastolic dysfunction severity reduced with sibutramine treatment. Also In addition, mean levels of adiponectin, TNF- alpha, fibrinogen and hs- CRP change with 19 months sibutramine treatment.
Molnar, Adrian; Muresan, Ioan; Trifan, Catalin; Pop, Dana; Sacui, Diana
2015-01-01
The introduction of Duke's criteria and the improvement of imaging methods has lead to an earlier and a more accurate diagnosis of infectious endocarditis (IE). The options for the best therapeutic approach and the timing of surgery are still a matter of debate and require a close colaboration between the cardiologist, the infectionist and the cardiac surgeon. We undertook a retrospective, descriptive study, spanning over a period of five years (from January 1st, 2007 to December 31st, 2012), on 100 patients who underwent surgery for native valve infectious endocarditis in our unit. The patients' age varied between 13 and 77 years (with a mean of 54 years), of which 85 were males (85%). The main microorganisms responsible for IE were: Streptococcus Spp. (21 cases - 21%), Staphylococcus Spp. (15 cases - 15%), and Enterococcus Spp. (9 cases - 9%). The potential source of infection was identified in 26 patients (26%), with most cases being in the dental area (16 cases - 16%). The lesions caused by IE were situated in the left heart in 96 patients (96%), mostly on the aortic valve (50 cases - 50%). In most cases (82%) we found preexisting endocardial lesions which predisposed to the development of IE, most of them being degenerative valvular lesions (38 cases - 38%). We performed the following surgical procedures: surgery on a single valve - aortic valve replacement (40 cases), mitral valve replacement (19 cases), mitral valve repair (1 case), surgery on more than one valve - mitral and aortic valve replacement (20 cases), aortic and tricuspid valve replacement (1 case), aortic valve replacement with a mechanical valve associated with mitral valve repair (5 cases), aortic valve replacement with a biological valve associated with mitral valve repair (2 cases), and mitral valve replacement with a mechanical valve combined with De Vega procedure on the tricuspid valve (1 case). In 5 patients (5%) the bacteriological examination of valve pieces excised during surgery was positive. In 3 cases it matched the germ identified in the hemocultures, and in 2 cases it evidenced another bacterium. The overall mortality of 5% is well between the limits presented in literature, being higher (30%) in patients who required emergency surgery. For the patients who return into our clinic with prosthetic valve endocarditis, the mortality after surgery was even higher (50%).
Intravalvular Implantation of Mitral Valve Prostheses
Cooley, Denton A.; Ingram, Michael T.
1987-01-01
We describe a technique of intravalvular implantation of a low-profile prosthesis that has been used in nine patients with mitral valve lesions. This technique preserves the anterior and posterior chordae and papillary mechanisms, which may decrease the incidence of postoperative left ventricular dysfunction that has been noted following standard mitral valve replacement. The technique may also be useful in some patients with aortic and tricuspid regurgitation when the annulus and leaflets are relatively normal pathologically. (Texas Heart Institute Journal 1987;14:188-193) PMID:15229740
Ren, X S; Yu, Y T; Liu, K; Hou, Z H; Gao, Y; Yin, W H; Lyu, B
2017-06-24
Objective: To compare the characteristics of aortic valve dysfunction and ascending aorta dimension in patients with different bicuspid aortic valve (BAV) morphology. Methods: A total of 197 patients who underwent aortic valve replacement between April 2014 and March 2015 and were diagnosed with BAV by pathology were included, and their clinical data were retrospectively analyzed. Patients were divided into raphe(+) group(109 cases) and raphe(-) group(88 cases) according to the presence or absence of raphe, and L-R group(fusion of left and right cusp, 125 cases) and L/R-N group(fusion of left or right and noncoronary cusp, 72 cases) according to fusion type of the cusps. The characteristics of aortic valve dysfunction and ascending aorta dimension in patients with different BAV morphology were compared. Results: (1) Aortic stenosis incidence was lower in raphe(+) group than in raphe(-) group(22.9%(25/109) vs. 69.3%(61/88), P <0.001). Aortic regurgitation incidence was higher in raphe(+) group than in raphe(-) group (61.5%(67/109) vs. 22.7%(20/88), P <0.001). Incidence of type 1 of aortic root dilation was higher in raphe(+) group than in raphe(-) group (23.9%(26/109)vs.10.2%(9/88), P =0.024). (2) Aortic stenosis incidence was lower in L-R group than in L/R-N group(29.6%(37/125) vs. 68.1%(49/72), P <0.001). Aortic regurgitation incidence was higher in L-R group than in L/R-N group (59.2%(74/125) vs. 18.1%(13/72), P <0.001). Incidence of type 3 of aortic root dilation was lower in L-R group than in L/R-N group(10.4%(13/125) vs. 37.5%(27/72), P =0.006). (3) Aortic stenosis incidence was lower in L-R patients than in L/R-N patients(15.1%(13/86)vs. 52.2%(12/23), P =0.001), and aortic regurgitation incidence was higher in L-R patients than in L/R-N patients in raphe(+) group(73.3%(63/86)vs. 17.4%(4/23), P <0.001). Conclusion: There is significant difference in the type of valvular dysfunction and ascending aorta dilatation in patients with different morphological characteristics of BAV.
Failing stentless Bioprostheses in patients with carcinoid heart valve disease.
Schaefer, Andreas; Sill, Bjoern; Schoenebeck, Jeannette; Schneeberger, Yvonne; Reichenspurner, Hermann; Gulbins, Helmut
2015-03-27
Carcinoid tumor with consecutive endocardial fibroelastosis of the right heart, known as carcinoid heart valve disease (CHVD) or Hedinger's syndrome, is accompanied by combined right-sided valvular dysfunction with regurgitation and stenosis of the affected valves. Cardiac surgery with replacement of the tricuspid and/or pulmonary valve is an established therapeutic option for patients with Hedinger's syndrome. Little is known about the long term outcome and the choice of prosthesis for the pulmonal position is still a matter of debate. The authors report three cases of pulmonary valve replacement with stentless bioprostheses (Medtronic Freestyle, Medtronic PLC, Minneapolis, MN, USA) due to severe pulmonary valve degeneration in consequence of Hedinger's syndrome. All patients presented with re-stenosis of the pulmonal valve conduit at the height of the anastomoses in a premature fashion. Due to the increased risk for repeat surgical valve replacement, two patients were treated by transcatheter heart valves. We do not recommend the replacement of the pulmonary valve with stentless bioprostheses in patients with CHVD. These valves presented with an extreme premature degeneration and consecutive re-stenosis and heart failure.
The History of Nontraditional or Ectopic Placement of Reservoirs in Prosthetic Urology.
Perito, Paul; Wilson, Steven
2016-04-01
Reservoir placement during implantation of prosthetic urology devices has been problematic throughout the history of the surgical treatment of erectile dysfunction and urinary incontinence. We thought it would be interesting to review the history of reservoir placement leading up to current surgical techniques. To provide an overview of the past and present techniques for reservoir placement and discuss the evolutionary process leading to safe and effective placement of prosthetic reservoirs. We reviewed data pertaining to inflatable penile prosthesis (IPP) reservoirs and pressure-regulating balloons (PRB) in a chronological fashion, spanning 25 years. Main outcomes included a historical review of techniques for IPP reservoir and PRB placement leading to the subsequent incremental improvements in safety and efficacy when performing penile implants and artificial urinary sphincters. Prosthetic urologic reservoirs have traditionally been placed in the retropubic space. Over the years, urologists have attempted use of alternative spaces including peritoneal, epigastric, "ectopic," posterior to transversalis, and high submuscular. Current advances in prosthetic urologic reservoir placement allow safe and effective abdominal wall placement of reservoirs. These novel approaches appear to be so effective that urologists may now be able to cease using the traditional retropubic space for reservoir placement, even in the case of virgin pelves. Copyright © 2016 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.
Intermittent, Non Cyclic Severe Mechanical Aortic Valve Regurgitation
Choi, Jong Hyun; Song, Seunghwan; Lee, Myung-Yong
2013-01-01
Mechanical aortic prosthesis dysfunction can result from thrombosis or pannus formation. We describe an unusual case of intermittent, non cyclic mechanical aortic prosthesis dysfunction due to pannus formation with thrombus in the absence of systolic restriction of disk excursion, that presented with intermittent severe aortic regurgitation. PMID:24459568
Myers, Patrick O; Cikirikcioglu, Mustafa; Kalangos, Afksendiyos
2014-08-03
One third of patients with infective endocarditis will require operative intervention. Given the superiority of valve repair over valve replacement in many indications other than endocarditis, there has been increasing interest and an increasing number of reports of excellent results of valve repair in acute infective endocarditis. The theoretically ideal material for valve repair in this setting is non-permanent, "vanishing" material, not at risk of seeding or colonization. The goal of this contribution is to review currently available data on biodegradable materials for valve repair in infective endocarditis. Rigorous electronic and manual literature searches were conducted to identify reports of biodegradable materials for valve repair in infective endocarditis. Articles were identified in electronic database searches of Medline, Embase and the Cochrane Library, using a predetermined search strategy. 49 manuscripts were included in the review. Prosthetic materials needed for valve repair can be summarized into annuloplasty rings to remodel the mitral or tricuspid annulus, and patch materials to replace resected valvar tissue. The commercially available biodegradable annuloplasty ring has shown interesting clinical results in a single-center experience; however further data is required for validation and longer follow-up. Unmodified extra-cellular matrix patches, such as small intestinal submucosa, have had promising initial experimental and clinical results in non-infected valve repair, although in valve repair for endocarditis has been reported in only one patient, and concerns have been raised regarding their mechanical stability in an infected field. These evolving biodegradable devices offer the potential for valve repair with degradable materials replaced with autologous tissue, which could further improve the results of valve repair for infective endocarditis. This is an evolving field with promising experimental or initial clinical results, however long-term outcomes are lacking and further data is necessary to validate this theoretically interesting approach to infective endocarditis.
2014-01-01
Background One third of patients with infective endocarditis will require operative intervention. Given the superiority of valve repair over valve replacement in many indications other than endocarditis, there has been increasing interest and an increasing number of reports of excellent results of valve repair in acute infective endocarditis. The theoretically ideal material for valve repair in this setting is non-permanent, “vanishing” material, not at risk of seeding or colonization. The goal of this contribution is to review currently available data on biodegradable materials for valve repair in infective endocarditis. Discussion Rigorous electronic and manual literature searches were conducted to identify reports of biodegradable materials for valve repair in infective endocarditis. Articles were identified in electronic database searches of Medline, Embase and the Cochrane Library, using a predetermined search strategy. 49 manuscripts were included in the review. Prosthetic materials needed for valve repair can be summarized into annuloplasty rings to remodel the mitral or tricuspid annulus, and patch materials to replace resected valvar tissue. The commercially available biodegradable annuloplasty ring has shown interesting clinical results in a single-center experience; however further data is required for validation and longer follow-up. Unmodified extra-cellular matrix patches, such as small intestinal submucosa, have had promising initial experimental and clinical results in non-infected valve repair, although in valve repair for endocarditis has been reported in only one patient, and concerns have been raised regarding their mechanical stability in an infected field. Summary These evolving biodegradable devices offer the potential for valve repair with degradable materials replaced with autologous tissue, which could further improve the results of valve repair for infective endocarditis. This is an evolving field with promising experimental or initial clinical results, however long-term outcomes are lacking and further data is necessary to validate this theoretically interesting approach to infective endocarditis. PMID:25087015
Measurement and reconstruction of the leaflet geometry for a pericardial artificial heart valve.
Jiang, Hongjun; Campbell, Gord; Xi, Fengfeng
2005-03-01
This paper describes the measurement and reconstruction of the leaflet geometry for a pericardial heart valve. Tasks involved include mapping the leaflet geometries by laser digitizing and reconstructing the 3D freeform leaflet surface based on a laser scanned profile. The challenge is to design a prosthetic valve that maximizes the benefits offered to the recipient as compared to the normally operating naturally-occurring valve. This research was prompted by the fact that artificial heart valve bioprostheses do not provide long life durability comparable to the natural heart valve, together with the anticipated benefits associated with defining the valve geometries, especially the leaflet geometries for the bioprosthetic and human valves, in order to create a replicate valve fabricated from synthetic materials. Our method applies the concept of reverse engineering in order to reconstruct the freeform surface geometry. A Brown & Shape coordinate measuring machine (CMM) equipped with a HyMARC laser-digitizing system was used to measure the leaflet profiles of a Baxter Carpentier-Edwards pericardial heart valve. The computer software, Polyworks was used to pre-process the raw data obtained from the scanning, which included merging images, eliminating duplicate points, and adding interpolated points. Three methods, creating a mesh model from cloud points, creating a freeform surface from cloud points, and generating a freeform surface by B-splines are presented in this paper to reconstruct the freeform leaflet surface. The mesh model created using Polyworks can be used for rapid prototyping and visualization. To fit a freeform surface to cloud points is straightforward but the rendering of a smooth surface is usually unpredictable. A surface fitted by a group of B-splines fitted to cloud points was found to be much smoother. This method offers the possibility of manually adjusting the surface curvature, locally. However, the process is complex and requires additional manipulation. Finally, this paper presents a reverse engineered design for the pericardial heart valve which contains three identical leaflets with reconstructed geometry.
Challenges of coronary angiography and intervention in patients previously treated by TAVI.
Blumenstein, Johannes; Kim, Won-Keun; Liebetrau, Christoph; Gaede, Luise; Kempfert, Joerg; Walther, Thomas; Hamm, Christian; Möllmann, Helge
2015-08-01
Since the beginning of the transcatheter aortic valve implantation (TAVI) era, many prosthetic valves have entered clinical practice. TAVI prostheses differ regarding stent design and some may potentially interfere with diagnostic or interventional catheters. The aim of our analysis was to evaluate the feasibility of coronary angiography (CA) or percutaneous coronary intervention (PCI) in patients with prior TAVI. From 2011 to 2014, 1,000 patients were treated by TAVI at our center using eight different valve prostheses (Symetis ACURATE TA and ACURATE TF; Medtronic CoreValve and Engager; JenaValve, SJM Portico; Edwards Lifesciences SAPIEN and SAPIEN XT). In this analysis, all patients were included who underwent either CA or PCI after TAVI. CA or PCI were rated as fully feasible when coronary ostia could be fully intubated, partially feasible when coronary arteries could be displayed only unselectively or unfeasible when coronary arteries could not be displayed. A total of 35 patients underwent CA/PCI after TAVI at our hospital. In all patients with valves implanted in a subcoronary position (SAPIEN n = 19; JenaValve n = 1), selective intubation was feasible using standard catheters. Out of 15 patients with valve types that are placed over the coronary ostia (CoreValve n = 10, ACURATE n = 4, Portico n = 1), selective intubation of coronary arteries was not possible in 9 cases, even with the use of different diagnostic catheters. Full accessibility was possible only in 3 cases. In 2 cases, display of the right CA was only feasible using unselective aortography. In 1 case, coronary arteries could not be displayed at all immediately after a valve-in-valve procedure. CA or PCI after TAVI is usually feasible. Devices that are placed in a partially supracoronary position, however, can interfere with diagnostic or guiding catheters and impede straightforward intervention, especially when the prosthesis is not implanted in the correct position.
Koldsland, S; Svennevig, J L; Abdelnoor, M; Aas, H; Semb, G
1992-01-01
In the 18 months up to July 1983, 120 Björk-Shiley convexo-concave prostheses with 70 degrees opening angle were implanted in 47 women and 61 men aged 19-78 (mean 58.6) years. The prosthetic valves were aortic in 65 cases, mitral in 23 and both aortic and mitral in 20 cases. Emergency operation was required in ten cases, and concomitant surgery was performed in 43 (39.8%). The early mortality was 5.5%. A follow-up study, comprising 498 patient years, revealed 73.1% 5-year survival. There were three mechanical failures of prosthesis, in one of which re-replacement was successful. Elective prosthesis replacement was performed in four other cases judged to be at high risk of strut fracture.
Unusual course of infective endocarditis: acute renal failure progressing to chronic renal failure.
Sevinc, Alper; Davutoglu, Vedat; Barutcu, Irfan; Kocoglu, M Esra
2006-04-01
Infective endocarditis is an infection of the endocardium that usually involves the valves and adjacent structures. The classical fever of unknown origin presentation represents a minority of infective endocarditis. The presented case was a 21-yearold young lady presenting with acute renal failure and fever to the emergency room. Cardiac auscultation revealed a soft S1 and 4/6 apical holosystolic murmur extended to axilla. Echocardiography showed mobile fresh vegetation under the mitral posterior leaflet. She was diagnosed as having infective endocarditis. Hemodialysis was started with antimicrobial therapy. However, because of the presence of severe mitral regurgitation with left ventricle dilatation and large mobile vegetation, mitral prosthetic mechanical valve replacement was performed. Although treated with antibiotics combined with surgery, renal functions were deteriorated and progressed to chronic renal failure.
Gadhinglajkar, Shrinivas; Sreedhar, Rupa; Karunakaran, Jayakumar; Misra, Manoranjan; Somasundaram, Ganesh; Mathew, Thomas
2010-01-01
A pacing system infection may lead to infective endocarditis and systemic sepsis. Tricuspid valve surgery may be required if the valve is severely damaged in the process of endocarditis. Although, cardiopulmonary bypass is the safe choice for performing right-heart procedures, it may carry risk of inducing systemic inflammatory response and multi-organ dysfunction. Some studies have advocated TV surgery without institution of CPB. We report tricuspid valve excision using the off-pump inflow occlusion technique in a 68-year-old man. We also describe role of intra-operative TEE as a monitoring tool at different stages of the surgical procedure.
A Report on the Development of Rare Earth-Cobalt Permanent Magnet Technology - Japan.
1981-07-01
Implantable pumps and valves , head support harness in development). C. MICROWAVE AND ION BEAM TECHNOLOGY 1. Microwave Tubes: TWT PPM focusing, klystrons...III and IV were devoted to various medical applications that employ REPM. These included various dental prosthetic devices, tech- niques for measuring...minimize losses due to fracture in handling or heat treatment. Very little work has been done on this topic in the West or in Japan. The only two papers
Effects of Extremity Armor on Metabolic Cost and Gait Biomechanics
2010-05-26
of prosthetics , orthotics, and exercise equipment could benefit from knowing the tipping point at which a mass on the limb begins to effect metabolic...measured. For this, you wear a nose clip and 4 breathe through a rubber mouthpiece and valve , similar to those found in scuba diving 5 equipment. The...32 33 Stress fractures , or breaks of bones in the foot and leg, have been associated with road 34 marching while carrying loads, especially
Reducing the open porosity of pyroboroncarbon articles
NASA Astrophysics Data System (ADS)
Martyushov, G. G.; Zakharevich, A. M.; Pichkhidze, S. Ya.; Koshuro, V. A.
2016-02-01
It is established that a decrease in the open porosity of pyroboroncarbon, a pyrolytic glassy composite material of interest for manufacturing prosthetic heart valves (PHVs), can be achieved via impregnation of articles with an alcohol solution of 3-aminopropyltriethoxysilane and subsequent thermal treatment. The maximum roughness height and linear size of open pores on the surface of PHV parts made of pyroboroncarbon can additionally be reduced by final mechanical processing of a silicon oxide film formed on the surface.
Østergaard, Lauge; Adelborg, Kasper; Sundbøll, Jens; Pedersen, Lars; Loldrup Fosbøl, Emil; Schmidt, Morten
2018-05-30
The positive predictive value of an infective endocarditis diagnosis is approximately 80% in the Danish National Patient Registry. However, since infective endocarditis is a heterogeneous disease implying long-term intravenous treatment, we hypothesiszed that the positive predictive value varies by length of hospital stay. A total of 100 patients with first-time infective endocarditis in the Danish National Patient Registry were identified from January 2010 - December 2012 at the University hospital of Aarhus and regional hospitals of Herning and Randers. Medical records were reviewed. We calculated the positive predictive value according to admission length, and separately for patients with a cardiac implantable electronic device and a prosthetic heart valve using the Wilson score method. Among the 92 medical records available for review, the majority of the patients had admission length ⩾2 weeks. The positive predictive value increased with length of admission. In patients with admission length <2 weeks the positive predictive value was 65% while it was 90% for admission length ⩾2 weeks. The positive predictive value was 81% for patients with a cardiac implantable electronic device and 87% for patients with a prosthetic valve. The positive predictive value of the infective endocarditis diagnosis in the Danish National Patient Registry is high for patients with admission length ⩾2 weeks. Using this algorithm, the Danish National Patient Registry provides a valid source for identifying infective endocarditis for research.
Infective endocarditis: the European viewpoint.
Tornos, Pilar; Gonzalez-Alujas, Teresa; Thuny, Frank; Habib, Gilbert
2011-05-01
Infective endocarditis (IE) is a difficult and complex disease. In recent years epidemiology and microbiology have changed. In developed countries IE is now affecting older patients and patients with no previously known valve disease. Prosthetic IE (prosthetic valve endocarditis [PVE]) and endocarditis in patients with pacemakers and other devices (cardiac device related infective endocarditis [CDRIE]) are becoming more frequent. The number of Staphylococcus aureus IE is increasing related to the number of endocarditis that occurs because of health care associated procedures, especially in diabetics or patients on chronic hemodialysis. The change in the underlying population and the increase in the number of cases caused by very virulent organism explain why the disease still carries a poor prognosis and a high mortality. The variety of clinical manifestations and complications, as well as the serious prognosis, makes it mandatory that IE patients need to be treated in experienced hospitals with a collaborative approach between different specialists, involving cardiologists, infectious disease specialists, microbiologists, surgeons, and frequently others, including neurologists and radiologists. Only an early diagnosis followed by risk stratification and a prompt institution of the correct antibiotic treatment as well as an appropriate and timed surgical indication may improve mortality figures. The recent European Guidelines try to provide clear and simple recommendations, obtained by expert consensus after thorough review of the available literature to all specialists involved in clinical decision-making of this difficult and changing disease. Copyright © 2011 Mosby, Inc. All rights reserved.
Yamanami, Masashi; Yahata, Yuki; Uechi, Masami; Fujiwara, Megumi; Ishibashi-Ueda, Hatsue; Kanda, Keiichi; Watanabe, Taiji; Tajikawa, Tsutomu; Ohba, Kenkichi; Yaku, Hitoshi; Nakayama, Yasuhide
2010-09-14
We developed autologous prosthetic implants by simple and safe in-body tissue architecture technology. We present the first report on the development of autologous valved conduit with the sinus of Valsalva (BIOVALVE) by using this unique technology and its subsequent implantation in the pulmonary valves in a beagle model. A mold of BIOVALVE organization was assembled using 2 types of specially designed silicone rods with a small aperture in a trileaflet shape between them. The concave rods had 3 projections that resembled the protrusions of the sinus of Valsalva. The molds were placed in the dorsal subcutaneous spaces of beagle dogs for 4 weeks. The molds were covered with autologous connective tissues. BIOVALVEs with 3 leaflets in the inner side of the conduit with the sinus of Valsalva were obtained after removing the molds. These valves had adequate burst strength, similar to that of native valves. Tight valvular coaptation and sufficient open orifice area were observed in vitro. These BIOVALVEs were implanted to the main pulmonary arteries as allogenic conduit valves (n=3). Postoperative echocardiography demonstrated smooth movement of the leaflets with trivial regurgitation. Histological examination of specimens obtained at 84 days showed that the surface of the leaflet was covered by endothelial cells and neointima, including an elastin fiber network, and was formed at the anastomosis sides on the luminal surface of the conduit. We developed the first completely autologous BIOVALVE and successfully implanted these BIOVALVEs in a beagle model in a pilot study.
Low pacemaker incidence with continuous-sutured valves: a retrospective analysis.
Niclauss, Lars; Delay, Dominique; Pfister, Raymond; Colombier, Sebastien; Kirsch, Matthias; Prêtre, René
2017-06-01
Background Permanent pacemaker implantation after surgical aortic valve replacement depends on patient selection and risk factors for conduction disorders. We aimed to identify risk criteria and obtain a selected group comparable to patients assigned to transcatheter aortic valve implantation. Methods Isolated sutured aortic valve replacements in 994 patients treated from 2007 to 2015 were reviewed. Demographics, hospital stay, preexisting conduction disorders, surgical technique, and etiology in patients with and without permanent pacemaker implantation were compared. Reported outcomes after transcatheter aortic valve implantation were compared with those of a subgroup including only degenerative valve disease and first redo. Results The incidence of permanent pacemaker implantation was 2.9%. Longer hospital stay ( p = 0.01), preexisting rhythm disorders ( p < 0.001), complex prosthetic endocarditis ( p = 0.01), and complex redo ( p < 0.001) were associated with permanent pacemaker implantation. Although prostheses were sutured with continuous monofilament in the majority of cases (86%), interrupted pledgetted sutures were used more often in the pacemaker group ( p = 0.002). In the subgroup analysis, the incidence of permanent pacemaker implantation was 2%; preexisting rhythm disorders and the suture technique were still major risk factors. Conclusion Permanent pacemaker implantation depends on etiology, preexisting rhythm disorders, and suture technique, and the 2% incidence compares favorably with the reported 5- to 10-fold higher incidence after transcatheter aortic valve implantation. Cost analysis should take this into account. Often dismissed as minor complication, permanent pacemaker implantation increases the risks of endocarditis, impaired myocardial recovery, and higher mortality if associated with prosthesis regurgitation.
Ostermeyer, J; Horstkotte, D; Bennett, J; Huysmans, H; Lindblom, D; Olin, C; Orinius, E; Semb, G
1987-04-01
Between June 1980 and June 1983 4028 Björk-Shiley 70 degree convexo-concave prosthetic heart valves were distributed and implanted in Australia, Canada, Europe and South Africa. As of March 1986, a total of 52 outlet strut fractures (1.29%; 70% CL: 1.1%-1.5%) have been reported from 29 implant institutions in 12 countries. The majority (82.7%) occurred in Europe. Intervals between implantation and fracture were 13 days to 45.3 months (mean: 18.4 months; 70% CL: 16.6 months-20.1 months). The mortality rate after strut fracture was 78.7% (70% CL: 72.5%-84.9%). Upon stratification of the fracture by valve sizes and types it becomes evident that 75% (70% CL: 68.8%-81.2%) of all fractures are related to the sizes 29 mm to 33 mm (which virtually represent the same valve size) and predominantly to mitral valves (p less than 0.01). The large valves again have been stratified into two subsets, namely those fabricated from flanges originally machined as Björk-Shiley 60 degree convexo-concave valves (group I) and later produced valves machined initially to 70 degree specifications (group II). In group I the fracture rate was 5.2% (70% CL: 4.2%-6.2%) versus 1.6% (70% CL: 1.1%-2.1%) in group II (p less than 0.01), which identifies the group I 29 mm-33 mm Björk-Shiley 70 degree convexo-concave valves as the highest risk group for strut fracture. The rates are based upon all available information as of March 16, 1986.(ABSTRACT TRUNCATED AT 250 WORDS)
Midterm Follow-Up of the Stentless Freedom Solo Bioprosthesis in 350 Patients.
Wollersheim, Laurens W; Li, Wilson W; Bouma, Berto J; Kaya, Abdullah; van Boven, Wim J; van der Meulen, Jan; de Mol, Bas A
2016-07-01
The stentless Freedom Solo aortic bioprosthesis is implanted supraannularly using one running suture line in the sinuses of Valsalva. We report our 9-year experience with this bioprosthesis. From April 2005 to July 2014, 350 consecutive patients at our institution underwent aortic valve replacement with the Freedom Solo bioprosthesis. Follow-up and echocardiographic data were collected retrospectively from referring cardiology centers. The mean age was 76 ± 6 years, 48% were male, and 46% underwent a concomitant procedure. Median EuroSCORE II was 3.0 (interquartile range, 1.9 to 4.9). Operative mortality was 5.1% for all procedures and 2.1% for isolated aortic valve replacement. The 1-, 5-, and 9-year overall survival was 92%, 74%, and 47%, respectively. At 6 years, freedom from structural valve deterioration and freedom from aortic valve reoperation were 98% and 96%, respectively. Prosthetic valve endocarditis occurred at a rate of 0.8% per patient-year. Permanent pacemaker implantation was necessary in 2.3% (n = 8), and moderate and severe prosthesis-patient mismatch occurred in 30 patients overall (9.6%). Postoperative maximum and mean valvular gradients were 17 mm Hg and 10 mm Hg, respectively, and remained stable during follow-up. Aortic valve replacement with the Freedom Solo is safe and has a low rate of permanent pacemaker implantations and prosthesis-patient mismatch. Survival is comparable to that with other aortic bioprostheses, and structural valve deterioration and aortic valve reoperation are infrequent during midterm follow-up. Hemodynamic performance is excellent, with low valvular gradients that remain stable during follow-up. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Capelli, Claudio; Corsini, Chiara; Biscarini, Dario; Ruffini, Francesco; Migliavacca, Francesco; Kocher, Alfred; Laufer, Guenther; Taylor, Andrew M; Schievano, Silvia; Andreas, Martin; Burriesci, Gaetano; Rath, Claus
2017-03-01
Surgical aortic valve replacement is the most common procedure of choice for the treatment of severe aortic stenosis. Bioprosthetic valves are traditionally sewed-in the aortic root by means of pledget-armed sutures during open-heart surgery. Recently, novel bioprostheses which include a stent-based anchoring system have been introduced to allow rapid implantation, therefore reducing the duration and invasiveness of the intervention. Different effects on the hemodynamics were clinically reported associated with the two technologies. The aim of this study was therefore to investigate whether the differences in hemodynamic performances are an effect of different anchoring systems. Two commercially available bio-prosthetic aortic valves, one sewed-in with pledget-armed sutures and one rapid-deployment, were thus tested in this study by means of a combined approach of experimental and computational tools. In vitro experiments were performed to evaluate the overall hydrodynamic performance under identical standard conditions; computational fluid dynamics analyses were set-up to explore local flow variations due to different design of the anchoring system. The results showed how the performance of cardiac valve substitutes is negatively affected by the presence of pledget-armed sutures. These are causing flow disturbances, which in turn increase the mean pressure gradient and decrease the effective orifice area. The combined approach of experiments and numerical simulations can be effectively used to quantify the detailed relationship between local fluid-dynamics and overall performances associated with different valve technologies.
Fluid Dynamics of the Heart and its Valves
NASA Astrophysics Data System (ADS)
Peskin, Charles S.
1997-11-01
The fluid dynamics of the heart involve the interaction of blood, a viscous incompressible fluid, with the flexible, elastic, fiber-reinforced heart valve leaflets that are immersed in that fluid. Neither the fluid motion nor the valve leaflet motion are known in advance: both must be computed simultaneously by solving their coupled equations of motion. This can be done by the immersed boundary method(Peskin CS and McQueen DM: A general method for the computer simulation of biological systems interacting with fluids. In: Biological Fluid Dynamics (Ellington CP and Pedley TJ, eds.), The Company of Biologists Limited, Cambridge UK, 1995, pp. 265-276.), which can be extended to incorporate the contractile fiber architecture of the muscular heart walls as well as the valve leaflets and the blood. In this way we arrive at a three-dimensional computer model of the heart(Peskin CS and McQueen DM: Fluid dynamics of the heart and its valves. In: Case Studies in Mathematical Modeling: Ecology, Physiology, and Cell Biology (Othmer HG, Adler FR, Lewis MA, and Dallon JC, eds.), Prentice-Hall, Englewood Cliffs NJ, 1996, pp. 309-337.), which can be used as a test chamber for the design of prosthetic cardiac valves, and also to study the function of the heart in health and in disease. Numerical solutions of the equations of cardiac fluid dynamics obtained by the immersed boundary method will be presented in the form of a video animation of the beating heart.
Lee Henry, Christopher; Ko, Jong Mi; Henry, Albert Carl; Matter, Gregory John
2011-01-01
Aortic valve replacement following an earlier coronary artery bypass grafting (CABG) procedure is fairly common. When this situation occurs, the type of valve dysfunction is usually stenosis (with or without regurgitation), and whether it was missed at the time of the earlier CABG or developed subsequently is usually unclear. We attempted to determine the survival in patients who had had aortic valve replacement after 2 previous CABG procedures. We describe 12 patients who had aortic valve replacement for aortic stenosis; rather than one previous CABG operation, all had had 2 previous CABG procedures. Only one patient died in the early postoperative period after aortic valve replacement, and the remaining 11 were improved substantially: all have lived at least 11 months, and one is still alive at over 101 months after aortic valve replacement. Aortic valve replacement remains beneficial for most patients even after 2 previous CABG procedures. PMID:21307968
Podesser, B K; Khuenl-Brady, G; Eigenbauer, E; Roedler, S; Schmiedberger, A; Wolner, E; Moritz, A
1998-05-01
The Edwards Duromedics valve (Baxter Healthcare Corp., Edwards Division, Santa Ana, Calif.) was designed with a self-irrigating hinge mechanism to reduce thromboembolic complications. After good initial clinical results, distribution was suspended in 1988 after reports of valve fracture after 20,000 valves had been implanted. The manufacturer conducted extensive studies to improve the Edwards Duromedics and reintroduced a modified version, which is available as Edwards Tekna. The purpose of the study was the evaluation of long-term results of the original Edwards Duromedics that might be important for the current version, the Edwards Tekna valve. A prospective clinical 10-year follow-up was performed of 508 patients who underwent valve replacement with the Edwards Duromedics valve in the aortic (n = 268), mitral (n = 183), and aortic and mitral (n = 56) position. The perioperative mortality rate was 6.9%; follow-up was 98% complete, comprising 3648 patient-years for a mean follow-up of 86 months (range: 33 to 144 months). The actuarial freedom from complications at the 10-year follow-up and the incidence rate (percent per patient-year) were as follows: late mortality rate, 69.2% +/- 2.4% (3.5% per patient-year); thromboembolism, 90.7% +/- 1.6% (0.96% per patient-year); anticoagulation-related hemorrhage, 87.7% +/- 1.7% (1.34% per patient-year); prosthetic valve endocarditis, 96.7% +/- 0.09% (0.38% per patient-year); valve-related mortality rate, 89.3% +/- 1.6% (1.21% per patient-year); valve failure, 86.2% +/- 1.85% (1.54% per patient-year); and valve-related morbidity and mortality rate, 71.1% +/- 2.3% (3.2% per patient-year). Three leaflet escapes were observed (one lethal, two successful reoperations; 99.1% +/- 0.05% freedom, 0.08% per patient-year). All patients functionally improved (86% in New York Heart Association classes I and II), and incidence of anemia was insignificant. These results confirm that the Edwards Duromedics valve shows excellent performance concerning thromboembolism, hemolysis, and functional improvement and will serve as a reference for the last version, the Edwards Tekna valve, where comparable long-term data are currently not available.
Tricuspid regurgitation after successful mitral valve surgery
Katsi, Vasiliki; Raftopoulos, Leonidas; Aggeli, Constantina; Vlasseros, Ioannis; Felekos, Ioannis; Tousoulis, Dimitrios; Stefanadis, Christodoulos; Kallikazaros, Ioannis
2012-01-01
The tricuspid valve (TV) is inseparably connected with the mitral valve (MV) in terms of function. Any pathophysiological condition concerning the MV is potentially a threat for the normal function of the TV as well. One of the most challenging cases is functional tricuspid regurgitation (TR) after surgical MV correction. In the past, TR was considered to progressively revert with time after left-sided valve restoration. Nevertheless, more recent studies showed that TR could develop and evolve postoperatively over time, as well as being closely associated with a poorer prognosis in terms of morbidity and mortality. Pressure and volume overload are usually the underlying pathophysiological mechanisms; structural alterations, like tricuspid annulus dilatation, increased leaflet tethering and right ventricular remodelling are almost always present when regurgitation develops. The most important risk factors associated with a higher probability of late TR development involve the elderly, female gender, larger left atrial size, atrial fibrillation, right chamber dilatation, higher pulmonary artery systolic pressures, longer times from the onset of MV disease to surgery, history of rheumatic heart disease, ischaemic heart disease and prosthetic valve malfunction. The time of TR manifestation can be up to 10 years or more after an MV surgery. Echocardiography, including the novel 3D Echo techniques, is crucial in the early diagnosis and prognosis of future TV disease development. Appropriate surgical technique and timing still need to be clarified. PMID:22457188
Prosthetic valve endocarditis: who needs surgery? A multicentre study of 104 cases
Habib, G; Tribouilloy, C; Thuny, F; Giorgi, R; Brahim, A; Amazouz, M; Remadi, J-P; Nadji, G; Casalta, J-P; Coviaux, F; Avierinos, J-F; Lescure, X; Riberi, A; Weiller, P-J; Metras, D; Raoult, D
2005-01-01
Objectives: To identify the prognostic markers of a bad outcome in a large population of 104 patients with prosthetic valve endocarditis (PVE), and to study the influence of medical versus surgical strategy on outcome in PVE and thus to identify patients for whom surgery may be beneficial. Design: Multicentre study. Methods and results: Among 104 patients, 22 (21%) died in hospital. Factors associated with in-hospital death were severe co-morbidity (6% of survivors v 41% of those who died, p = 0.05), renal failure (28% v 45%, p = 0.05), moderate to severe regurgitation (22% v 54%, p = 0.006), staphylococcal infection (16% v 54%, p = 0.001), severe heart failure (22% v 64%, p = 0.001), and occurrence of any complication (60% v 90%, p = 0.05). By multivariate analysis, severe heart failure (odds ratio 5.5) and Staphylococcus aureus infection (odds ratio 6.1) were the only independent predictors of in-hospital death. Among 82 in-hospital survivors, 21 (26%) died during a 32 month follow up. A Cox proportional hazards model identified early PVE, co-morbidity, severe heart failure, staphylococcus infection, and new prosthetic dehiscence as independent predictors of long term mortality. Mortality was not significantly different between surgical and non-surgical patients (17% v 25%, respectively, not significant). However, both in-hospital and long term mortality were reduced by a surgical approach in high risk subgroups of patients with staphylococcal PVE and complicated PVE. Conclusions: Firstly, PVE not only carries a high in-hospital mortality risk but also is associated with high long term mortality and needs close follow up after the initial episode. Secondly, congestive heart failure, early PVE, staphylococcal infection, and complicated PVE are associated with a bad outcome. Thirdly, subgroups of patients could be identified for whom surgery is associated with a better outcome: patients with staphylococcal and complicated PVE. Early surgery is strongly recommended for these patients. PMID:15958370
MOLNAR, ADRIAN; MURESAN, IOAN; TRIFAN, CATALIN; POP, DANA; SACUI, DIANA
2015-01-01
Background and aims The introduction of Duke’s criteria and the improvement of imaging methods has lead to an earlier and a more accurate diagnosis of infectious endocarditis (IE). The options for the best therapeutic approach and the timing of surgery are still a matter of debate and require a close colaboration between the cardiologist, the infectionist and the cardiac surgeon. Methods We undertook a retrospective, descriptive study, spanning over a period of five years (from January 1st, 2007 to December 31st, 2012), on 100 patients who underwent surgery for native valve infectious endocarditis in our unit. Results The patients’ age varied between 13 and 77 years (with a mean of 54 years), of which 85 were males (85%). The main microorganisms responsible for IE were: Streptococcus Spp. (21 cases – 21%), Staphylococcus Spp. (15 cases – 15%), and Enterococcus Spp. (9 cases – 9%). The potential source of infection was identified in 26 patients (26%), with most cases being in the dental area (16 cases – 16%). The lesions caused by IE were situated in the left heart in 96 patients (96%), mostly on the aortic valve (50 cases – 50%). In most cases (82%) we found preexisting endocardial lesions which predisposed to the development of IE, most of them being degenerative valvular lesions (38 cases – 38%). We performed the following surgical procedures: surgery on a single valve - aortic valve replacement (40 cases), mitral valve replacement (19 cases), mitral valve repair (1 case), surgery on more than one valve – mitral and aortic valve replacement (20 cases), aortic and tricuspid valve replacement (1 case), aortic valve replacement with a mechanical valve associated with mitral valve repair (5 cases), aortic valve replacement with a biological valve associated with mitral valve repair (2 cases), and mitral valve replacement with a mechanical valve combined with De Vega procedure on the tricuspid valve (1 case). In 5 patients (5%) the bacteriological examination of valve pieces excised during surgery was positive. In 3 cases it matched the germ identified in the hemocultures, and in 2 cases it evidenced another bacterium. Conclusion The overall mortality of 5% is well between the limits presented in literature, being higher (30%) in patients who required emergency surgery. For the patients who return into our clinic with prosthetic valve endocarditis, the mortality after surgery was even higher (50%). PMID:26609267
Study of the Pressure and Velocity Across the Aortic Valve
NASA Astrophysics Data System (ADS)
Kyung, Seo Young; Chung, Erica Soyun; Lee, Joo Hee; Kyung, Hayoung; Choi, Si Young
Biomechanics of the heart, requiring an extensive understanding of the complexity of the heart, have become the interests of many biomedical engineers in cardiology today. In order to study aortic valve disease, engineers have focused on the data obtained through bio-fluid flow analysis. To further this study, physical and computational analysis on the biomechanical determinants of blood flow in the stenosed aortic valve have been examined. These observations, along with the principles of cardiovascular physiology, confirm that when blood flows through the valve opening, pressure gradient across the valve is produced as a result of stenosis of the aortic valve. The aortic valve gradient is used to interpret the increase and decrease on each side of the defective valve. To compute different pressure gradients across the aortic valve, this paper analyzes Aortic Valve Areas (AVA) using simulations based on the continuity equation and Gorlin equation. The data obtained from such analysis consist of patients in the AS category that display mild Aortic Valve Velocity (AVV) and pressure gradient. Such correlation results in the construction of a dependent relationship between severe AS causing LV systolic dysfunction and the transaortic velocity.
2010-04-01
that are now digitally enhanced and also part-task trainers (attrappe). Paper 12 – Using Advanced Prosthetics for Stress Inoculation Training and to...concept of minimum treatment called the “Just seven procedure”: just bridge the fracture , just align the limb, just stiff enough to allow evacuation...require energy, some more than others. Oxygen economizing systems like on-demand valves should be compulsory for spontaneous ventilation. Pulseoximeters
Transforming Growth Factor Beta-2 Mutations in Barlow's Disease and Aortic Dilatation.
Disha, Kushtrim; Schulz, Solveig; Kuntze, Thomas; Girdauskas, Evaldas
2017-07-01
We report on a patient operated on for degenerative myxomatous mitral and tricuspid valve disease (Barlow's disease) and aortic root dilatation. A valve repair operation and the postoperative course were uneventful. Multigenerational genetic analyses revealed two different mutations in the transforming growth factor beta-2 gene in the same patient. The two mutations in different exons were inherited from both parents each. None of the parents presented with either valve dysfunction or aortic root dilatation. This rare case illustrates potentially common genetic and signaling pathways of concomitant myxomatous valve disease and aortic root dilatation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Ruivo, Catarina; Guardado, Joana; Montenegro Sá, Fernando; Saraiva, Fátima; Antunes, Alexandre; Correia, Joana; Morais, João
2017-07-01
We report a clinical case of a 40-year-old male with surgically corrected congenital heart disease (CHD) 10 years earlier: closure of ostium primum, mitral annuloplasty, and aortic valve and root surgery. The patient was admitted with acute heart failure. Transesophageal echocardiography (TEE) revealed a dysmorphic and severely incompetent aortic valve, a partial tear of the mitral valve cleft repair and annuloplasty ring dehiscence. A true left ventricular-to-right atrial shunt confirmed a direct Gerbode defect. The authors aim to discuss the diagnostic challenge of adult CHD, namely the key role of TEE on septal defects and valve regurgitations description. © 2017, Wiley Periodicals, Inc.
Understanding Lymphatic Valve Function via Computational Modeling
NASA Astrophysics Data System (ADS)
Wolf, Ki; Nepiyushchikh, Zhanna; Razavi, Mohammad; Dixon, Brandon; Alexeev, Alexander
2017-11-01
The lymphatic system is a crucial part to the circulatory system with many important functions, such as transport of interstitial fluid, fatty acid, and immune cells. Lymphatic vessels' contractile walls and valves allow lymph flow against adverse pressure gradients and prevent back flow. Yet, the effect of lymphatic valves' geometric and mechanical properties to pumping performance and lymphatic dysfunctions like lymphedema is not well understood. Our coupled fluid-solid computational model based on lattice Boltzmann model and lattice spring model investigates the dynamics and effectiveness of lymphatic valves in resistance minimization, backflow prevention, and viscoelastic response under different geometric and mechanical properties, suggesting the range of lymphatic valve parameters with effective pumping performance. Our model also provides more physiologically relevant relations of the valve response under varied conditions to a lumped parameter model of the lymphatic system giving an integrative insight into lymphatic system performance, including its failure due to diseases. NSF CMMI-1635133.
NASA Astrophysics Data System (ADS)
Jeyhani, Morteza; Shahriari, Shahrokh; Labrosse, Michel; Kadem, Lyes
2013-11-01
Approximately 500,000 people in North America suffer from mitral valve regurgitation (MR). MR is a disorder of the heart in which the mitral valve (MV) leaflets do not close securely during systole. Edge-to-edge repair (EtER) technique can be used to surgically treat MR. This technique produces a double-orifice configuration for the MV. Under these un-physiological conditions, flow downstream of the MV forms a double jet structure that may disturb the intraventricular hemodynamics. Abnormal flow patterns following EtER are mainly characterized by high-shear stress and stagnation zones in the left ventricle (LV), which increase the potential of blood component damage. In this study, a custom-made prosthetic bicuspid MV was used to analyze the LV flow patterns after EtER by means of digital particle image velocimetry (PIV). Although the repair of a MV using EtER technique is an effective approach, this study confirms that EtER leads to changes in the LV flow field, including the generation of a double mitral jet flow and high shear stress regions.
3D Fluid-Structure Interaction Simulation of Aortic Valves Using a Unified Continuum ALE FEM Model.
Spühler, Jeannette H; Jansson, Johan; Jansson, Niclas; Hoffman, Johan
2018-01-01
Due to advances in medical imaging, computational fluid dynamics algorithms and high performance computing, computer simulation is developing into an important tool for understanding the relationship between cardiovascular diseases and intraventricular blood flow. The field of cardiac flow simulation is challenging and highly interdisciplinary. We apply a computational framework for automated solutions of partial differential equations using Finite Element Methods where any mathematical description directly can be translated to code. This allows us to develop a cardiac model where specific properties of the heart such as fluid-structure interaction of the aortic valve can be added in a modular way without extensive efforts. In previous work, we simulated the blood flow in the left ventricle of the heart. In this paper, we extend this model by placing prototypes of both a native and a mechanical aortic valve in the outflow region of the left ventricle. Numerical simulation of the blood flow in the vicinity of the valve offers the possibility to improve the treatment of aortic valve diseases as aortic stenosis (narrowing of the valve opening) or regurgitation (leaking) and to optimize the design of prosthetic heart valves in a controlled and specific way. The fluid-structure interaction and contact problem are formulated in a unified continuum model using the conservation laws for mass and momentum and a phase function. The discretization is based on an Arbitrary Lagrangian-Eulerian space-time finite element method with streamline diffusion stabilization, and it is implemented in the open source software Unicorn which shows near optimal scaling up to thousands of cores. Computational results are presented to demonstrate the capability of our framework.
3D Fluid-Structure Interaction Simulation of Aortic Valves Using a Unified Continuum ALE FEM Model
Spühler, Jeannette H.; Jansson, Johan; Jansson, Niclas; Hoffman, Johan
2018-01-01
Due to advances in medical imaging, computational fluid dynamics algorithms and high performance computing, computer simulation is developing into an important tool for understanding the relationship between cardiovascular diseases and intraventricular blood flow. The field of cardiac flow simulation is challenging and highly interdisciplinary. We apply a computational framework for automated solutions of partial differential equations using Finite Element Methods where any mathematical description directly can be translated to code. This allows us to develop a cardiac model where specific properties of the heart such as fluid-structure interaction of the aortic valve can be added in a modular way without extensive efforts. In previous work, we simulated the blood flow in the left ventricle of the heart. In this paper, we extend this model by placing prototypes of both a native and a mechanical aortic valve in the outflow region of the left ventricle. Numerical simulation of the blood flow in the vicinity of the valve offers the possibility to improve the treatment of aortic valve diseases as aortic stenosis (narrowing of the valve opening) or regurgitation (leaking) and to optimize the design of prosthetic heart valves in a controlled and specific way. The fluid-structure interaction and contact problem are formulated in a unified continuum model using the conservation laws for mass and momentum and a phase function. The discretization is based on an Arbitrary Lagrangian-Eulerian space-time finite element method with streamline diffusion stabilization, and it is implemented in the open source software Unicorn which shows near optimal scaling up to thousands of cores. Computational results are presented to demonstrate the capability of our framework. PMID:29713288
Biocor No- React stentless aortic valve--short-term results.
Von Oppell, U O; Stemmet, F; Levetan, B; Heijke, S A; Brink, J
2001-01-01
Short-term results of the bioprosthetic Biocor No-React composite porcine stentless aortic valve (Biocor Industria e Pesquisas LTDA, Belo Horizonte, Brazil) implanted in patients in whom anticoagulation was thought to be contraindicated or expected to be non-compliant. Retrospective review of 52 consecutive prospective patients in whom this valve was implanted, between September 1994 and May 1998. Average age was 44 +/- 17 years; 75% of patients were operated on for rheumatic heart disease and combined procedures were done in 40% of cases. Early mortality was 5.8%, and related to pre-operative ejection fraction ( P < 0.03), New York Heart Association (NYHA) class (P < 0.01), and bacterial endocarditis (P < 0.04). On discharge, 84% of survivors were in NYHA class I and 16% in class II. The average postoperative prosthetic valve peak gradient on echocardiography was 19.9 +/- 11 mmHg and was related to pre-operative ejection fraction and smaller valve sizes. Postoperative residual trivial or mild aortic regurgitation was seen in 19 patients (36.6%), resolved on follow-up in 10 cases, and did not correlate with structural deterioration, re-operation, mortality, or widening of the non-coronary sinus. The non-coronary aortic sinus was widened on closure, because of perceived crowding of the adjacent stentless valve commisures, in 52% of cases. This was thought to be related to the use of an oblique as opposed to transverse aortotomy. Patient survival, inclusive of operative deaths, was 88.5%, and event-free survival was 80.0% at 4 years. The short-term results of this stentless aortic valve in a young predominantly third-world population group are acceptable, and appear to be superior to the results for mechanical valves in a similar patient group. We would recommend a transverse aortotomy above the sinotubular ridge to be the more appropriate aortotomy incision when using stentless aortic valves.
Intermediate results of isolated mitral valve replacement with a Biocor porcine valve.
Rizzoli, Giulio; Bottio, Tomaso; Vida, Vladimiro; Nesseris, Georgios; Caprili, Luca; Thiene, Gaetano; Gerosa, Gino
2005-02-01
We analyzed the intermediate experience, survival, and prosthetic complications of patients who received the Biocor valve, a new-generation porcine valve, in the mitral position. At the University of Padua, between May 1992 and January 2004, 154 consecutive patients (102 female and 52 male patients; mean age, 72.3 +/- 6 years; age range, 37-86 years) received 158 mitral Biocor prostheses (Biocor Industria e Pesguisa Ltda, Belo Horizonte, Brazil). Thirty-five percent of the patients had previous mitral operations, 24% had coronary artery bypass grafting, and 34.6% had other procedures. Median preoperative New York Heart Association class was III. Echocardiography was performed in 75% of the long-term survivors. Follow-up included 609.4 patient-years and was 100% complete, with a median time of 4 patient-years (range, 0.02-11.3 years). At 8 years, 20 (14%) of 142 operative survivors were still at risk. Early mortality was 13.6%. According to univariate analysis, New York Heart Association class III to IV, ejection fraction of less than 40%, urgency, male sex, and coronary artery bypass grafting were significant perioperative risk factors. Eight- and 10-year actuarial survival was 51.1% +/- 5.6% (40 deaths). Eight-year actuarial freedom from valve-related death, thromboembolism, anticoagulant-related hemorrhage, endocarditis, paravalvular leak, and valve-related complications were 85.2% +/- 5%, 85.7% +/- 4.4%, 92.6% +/- 3.7%, 94.1% +/- 3%, 91.8% +/- 3%, and 70.2% +/- 5.7%, respectively. Freedom from structural valve deterioration was 100%. Actual freedom from reoperation was 93.2% +/- 2.2%. By Doppler echocardiography, the peak and mean transprosthetic gradients were 15 +/- 5 mm Hg and 6.3 +/- 3 mm Hg, respectively (mean follow-up, 4.2 +/- 2.7 years). At intermediate follow-up, the Biocor prosthesis in the mitral position showed excellent results in terms of valve durability when compared with other second-generation tissue valves.
Goffin, Y; Grandmougin, D; Van Hoeck, B
1996-01-01
The heart valve bank of the European Homograft Bank has been set up in 1988 to meet the growing demand of cardiac surgeons for various sized and quality controlled cryopreserved homografts. Heart valve donors less than 60 years of age were classified in 3 categories: multiorgan donors with non transplantable hearts, recipients of cardiac transplantation and non beating heart cadavers with a warm ischemic time of less than 6 hours. Past history and biology were checked for transmissible diseases. Preparation, progressive freezing and storage in liquid nitrogen vapors, and quality control were according to the standards of the Belgian Ministry of Health. From end January 1989 to end May 1994, 989 homograft valves were cryopreserved (514 pulmonary, 475 aortic and 3 mitral) whereas 962 valves were discarded. The first cause of rejection being a major macroscopic lesion (41.48%). 138 hearts accepted at inspection were contaminated and 43 cases remained so after antibiotics. 38 cases were positive for hepatitis B or C. Complication at distribution and thawing included 10 instances of bag rupture and 15 of transversal fracture through the wall of the conduit. 477 aortic, 474 pulmonary valves as well as one mitral were implanted between May 1989 and May 1994, either for left or right ventricular outflow tract reconstruction. In the left ventricular outflow tract series 111 aortic and 23 pulmonary homograft valves were used in cases of native endocarditis, prosthetic endocarditis or recurrent endocarditis after homograft implantation. 9.6% of the requests could no be satisfied. Regular follow up information was available from 382 implants-40.1% only. The assessment of 5 years operation of the heart valve bank indicates: 1) the efficiency of selecting, cryopreserving and allocating quality controlled homograft valves from a large pool of donor hearts provided by a network of hospitals; 2) the difficulty of obtaining regular follow up information on the implants.
Health care-associated native valve endocarditis: importance of non-nosocomial acquisition.
Benito, Natividad; Miró, José M; de Lazzari, Elisa; Cabell, Christopher H; del Río, Ana; Altclas, Javier; Commerford, Patrick; Delahaye, Francois; Dragulescu, Stefan; Giamarellou, Helen; Habib, Gilbert; Kamarulzaman, Adeeba; Kumar, A Sampath; Nacinovich, Francisco M; Suter, Fredy; Tribouilloy, Christophe; Venugopal, Krishnan; Moreno, Asuncion; Fowler, Vance G
2009-05-05
The clinical profile and outcome of nosocomial and non-nosocomial health care-associated native valve endocarditis are not well defined. To compare the characteristics and outcomes of community-associated and nosocomial and non-nosocomial health care-associated native valve endocarditis. Prospective cohort study. 61 hospitals in 28 countries. Patients with definite native valve endocarditis and no history of injection drug use who were enrolled in the ICE-PCS (International Collaboration on Endocarditis Prospective Cohort Study) from June 2000 to August 2005. Clinical and echocardiographic findings, microbiology, complications, and mortality. Health care-associated native valve endocarditis was present in 557 (34%) of 1622 patients (303 with nosocomial infection [54%] and 254 with non-nosocomial infection [46%]). Staphylococcus aureus was the most common cause of health care-associated infection (nosocomial, 47%; non-nosocomial, 42%; P = 0.30); a high proportion of patients had methicillin-resistant S. aureus (nosocomial, 57%; non-nosocomial, 41%; P = 0.014). Fewer patients with health care-associated native valve endocarditis had cardiac surgery (41% vs. 51% of community-associated cases; P < 0.001), but more of the former patients died (25% vs. 13%; P < 0.001). Multivariable analysis confirmed greater mortality associated with health care-associated native valve endocarditis (incidence risk ratio, 1.28 [95% CI, 1.02 to 1.59]). Patients were treated at hospitals with cardiac surgery programs. The results may not be generalizable to patients receiving care in other types of facilities or to those with prosthetic valves or past injection drug use. More than one third of cases of native valve endocarditis in non-injection drug users involve contact with health care, and non-nosocomial infection is common, especially in the United States. Clinicians should recognize that outpatients with extensive out-of-hospital health care contacts who develop endocarditis have clinical characteristics and outcomes similar to those of patients with nosocomial infection. None.
Cheng, Zhuo; Kidher, Emaddin; Jarral, Omar A; O'Regan, Declan P; Wood, Nigel B; Athanasiou, Thanos; Xu, Xiao Yun
2016-05-01
This paper presents the analysis of detailed hemodynamics in the aortas of four patients following replacement with a composite bio-prosthetic valve-conduit. Magnetic resonance image-based computational models were set up for each patient with boundary conditions comprising subject-specific three-dimensional inflow velocity profiles at the aortic root and central pressure waveform at the model outlet. Two normal subjects were also included for comparison. The purpose of the study was to investigate the effects of the valve-conduit on flow in the proximal and distal aorta. The results suggested that following the composite valve-conduit implantation, the vortical flow structure and hemodynamic parameters in the aorta were altered, with slightly reduced helical flow index, elevated wall shear stress and higher non-uniformity in wall shear compared to normal aortas. Inter-individual analysis revealed different hemodynamic conditions among the patients depending on the conduit configuration in the ascending aorta, which is a key factor in determining post-operative aortic flow. Introducing a natural curvature in the conduit to create a smooth transition between the conduit and native aorta may help prevent the occurrence of retrograde and recirculating flow in the aortic arch, which is particularly important when a large portion or the entire ascending aorta needs to be replaced.
Roos, Carolyn M.; Hagler, Michael; Zhang, Bin; Oehler, Elise A.; Arghami, Arman
2013-01-01
The purpose of this study was to characterize changes in antioxidant and age-related gene expression in aorta and aortic valve with aging, and test the hypothesis that increased mitochondrial oxidative stress accelerates age-related endothelial and aortic valve dysfunction. Wild-type (MnSOD+/+) and manganese SOD heterozygous haploinsufficient (MnSOD+/−) mice were studied at 3 and 18 mo of age. In aorta from wild-type mice, antioxidant expression was preserved, although there were age-associated increases in Nox2 expression. Haploinsufficiency of MnSOD did not alter antioxidant expression in aorta, but increased expression of Nox2. When compared with that of aorta, age-associated reductions in antioxidant expression were larger in aortic valves from wild-type and MnSOD haploinsufficient mice, although Nox2 expression was unchanged. Similarly, sirtuin expression was relatively well-preserved in aorta from both genotypes, whereas expression of SIRT1, SIRT2, SIRT3, SIRT4, and SIRT6 were significantly reduced in the aortic valve. Expression of p16ink4a, a marker of cellular senescence, was profoundly increased in both aorta and aortic valve from MnSOD+/+ and MnSOD+/− mice. Functionally, we observed comparable age-associated reductions in endothelial function in aorta from both MnSOD+/+ and MnSOD+/− mice. Interestingly, inhibition of NAD(P)H oxidase with apocynin or gp91ds-tat improved endothelial function in MnSOD+/+ mice but significantly impaired endothelial function in MnSOD+/− mice at both ages. Aortic valve function was not impaired by aging or MnSOD haploinsufficiency. Changes in antioxidant and sirtuin gene expression with aging differ dramatically between aorta and aortic valve. Furthermore, although MnSOD does not result in overt cardiovascular dysfunction with aging, compensatory transcriptional responses to MnSOD deficiency appear to be tissue specific. PMID:23997094
Heart valve bioprosthesis durability: a challenge to the new generation of porcine valves.
Valente, M; Minarini, M; Maizza, A F; Bortolotti, U; Thiene, G
1992-01-01
Long-term experience with first generation porcine valve xenografts enabled identification of the major limitations to their durability: (1) prosthetic-ventricular mismatch due to the high profile of the stent in patients with mitral stenosis and a small left ventricle; (2) high-pressure fixation with loss of natural collagen crimping in the fibrosa, and wash-out of proteoglycans in the spongiosa; (3) xenograft tissue autolysis, due to the long interval between animal slaughter and aortic valve removal fixation; (4) muscle shelf in the right coronary cusp, which created a gradient and could undergo accelerated calcification and/or spontaneous perforation with time; (5) a flexible polypropylene stent, which could creep or even fracture with consequent inward bending of the stent; (6) progressive time-related dystrophic calcification; (7) host fibrous tissue ingrowth. An awareness of these limitations stimulated technical modifications, which frequently brought about distinct improvements: (1) the reduction of the stent profile eliminated the problem of mismatch, but resulted in a higher tendency towards cusp prolapse and earlier commissural tearing; (2) natural collagen waviness, proteoglycans and cusp extensibility were preserved by employing low or even zero pressure during the fixation process; (3) earlier valve fixation enabled preservation of cell integrity; (4) a new orifice for small valves was designed by replacing the right muscular cusp, thus achieving less gradient and avoiding muscle-shelf-related complications; (5) polypropylene was replaced by Delrin as stent material; (6) calcium-retarding agents like T6 and toluidine blue were applied during commercial processing and storage in order to mitigate tissue mineralization.(ABSTRACT TRUNCATED AT 250 WORDS)
Ferratini, Maurizio; Marianeschi, Stefano; Vitali, Ettore; Iorio, Fiore; Moraschi, Andrea; Pezzano, Antonio; Mauri, Luigi; Lorini, Saverio; Rambaldi, Roberto; Tersalvi, Carlo Alberto; Pesaresi, Marilena; Pllumi, Arketa; Santoro, Francesco
2007-08-01
In 2001 the Cardiac Rehabilitation Unit IRCCS S. Maria Nascente Center and the International Area of Don Carlo Gnocchi Foundation, in collaboration with the Cardiac Surgery Department "De Gasperis" of Niguarda Ca' Granda Hospital in Milan, planned a project to treat children from impoverished countries. The "Fondo Sanitario Regionale" of the Lombard Region cosponsored the program. From October 2001 to November 2006, 32 patients (25 from Zimbabwe and 7 from Albania) were selected and submitted to cardiac surgery: 22 patients were affected by acquired valvular heart disease in NYHA class III-IV, 10 by congenital heart disease. After surgery the patients admitted to our rehabilitation unit underwent a period of comprehensive cardiac rehabilitation. Afterwards, the patients were in the care of selected Italian families for about 3 months. In both populations the problems faced in the selection, management and surgical approach are discussed. At 21 months the survival of the whole study population was 93 % (2 valvular patients died during the follow-up); 2 patients who initially underwent mitral valve repair were submitted to valve replacement for late appearance of severe regurgitation. In 3 patients with mitral valve bioprosthesis a significant structural valve deterioration occurred in the follow-up and 2 of them underwent valve replacement. The advantage of the excellent performance in durability of mechanical prosthetic valves (with respect to the limited durability of porcine bioprostheses), the problems with long-term anticoagulation have to be taken into consideration in the management of patients coming from socio-economically deprived areas.
Flail tricuspid valve secondary to blunt chest trauma
Srinivas, Sunil Kumar; Patil, Shivanand; Ramalingam, Rangaraj; Bhairappa, Shivakumar
2012-01-01
A 78-year-old man admitted with complaints of breathlessness of 1 year and typical chest pain of 2 months duration. He had a blunt chest trauma 7 years back. Transthoracic echocardiography revealed severe tricuspid regurgitation due to a flail anterior leaflet of the tricuspid valve. It also revealed global left ventricular dysfunction. Flail tricuspid valve causing severe regurgitation is usually due to mechanical trauma. Since it is well tolerated for years, the diagnosis may be delayed or missed entirely. Echocardiography has allowed easier diagnosis of this condition resulting in earlier and, hence, more effective treatment. PMID:22922931
Horstkotte, D; Schulte, H D; Niehues, R; Klein, R M; Piper, C; Strauer, B E
1993-09-01
Forty-two consecutive patients received emergency treatment for acute mitral insufficiency causing pulmonary edema between 1984 and 1992. The underlying diagnoses were acute myocardial infarction (n = 21), acute bacterial endocarditis on the native mitral valve (n = 9), prosthetic endocarditis in the mitral position (n = 4), acute failure of a replacement valve (n = 5), blunt chest trauma (n = 1) and chordal rupture in Marfan's syndrome (n = 2). Dysfunction of the subvalvular apparatus was present in 24 patients, verified by transthoracic echocardiography in 18 (75%) and by transoesophageal echocardiography in all patients in whom this technique was used. There were four cases of outflow strut fracture of a Björk-Shiley mitral prosthesis; a reliable diagnosis was made by fluoroscopy in all patients. Bedside hemodynamic monitoring was found to be unreliable both for differential diagnosis and for the quantitative assessment of the degree of mitral insufficiency. The right ventricular filling pressure was normal in 32/39 patients (82%), and the pulmonary artery and pulmonary capillary pressures elevated in 37/39 (95%). Diagnostically important, high pulmonary capillary v-waves were documented in 13 patients (33%). The left ventricular impedance could be influenced with sodium nitroprussid combined in some cases with dobutamin, and the resultant decrease of the peripheral vascular resistance from 1480 +/- 222 to 702 +/- 86 dyn x sec x cm-5 was followed by a proportionate reduction in the transmitral regurgitant fraction. Three patients died prior to the intended emergency surgical intervention. Emergency surgery was completed in 21 patients with an early mortality of 23.8% (n = 5). Ten patients underwent elective surgery within, and another three later than one year from the onset of the acute symptoms with an early mortality of 7.7% (n = 1). Four patients are alive and clinically well with medical treatment alone.
Rose, Alan G; Park, Soon J
2005-01-01
Ventricular assist devices (VADs) are used as a bridge to cardiac transplantation or as a permanent or sometimes temporary treatment for end stage heart failure. Our autopsy and surgical pathology experience with VADs prior to August 2002 was reviewed. Noted were patient's age, sex, underlying (UCOD) and proximate causes of death (PCOD), duration of VAD implantation, presence of native or prosthetic valvar disease and organ complications. Myocardium from biopsies and explanted hearts were blindly assessed for coagulative necrosis (CN), contraction bands (CB), myocytolysis (MC), increased eosinophilia (IE), myocyte waviness (MW) and fibrosis (F). Each was graded as either mild (score 1), moderate (score 2) or severe (score 3). Autopsy patients: Twenty-one patients, with mean age 55 years (range 10-73), comprised 10 women and 11 men. UCOD was ischemic disease in 16 patients, dilated cardiomyopathy in 4 and aortic valve disease in 1. The mean duration of VAD implantation was 125.7 days (range 1-1095 days, S.D.=253.6). Five patients had biventricular VADs, and 16 had LVAD only. Acquired aortic valve fusion was noted in three patients. PCOD was VAD related in six, donor heart problem in four, cerebrovascular accident in four, miscellaneous in three, pulmonary hypertension in two and aortic disease in two patients. Morbidity: local liver necrosis in seven, acquired aortic valve disease in four, gut infarction in three, abdominal aortic aneurysm in two and host cell assault against VAD porcine aortic valves in one case. Biopsies and explanted hearts: Twenty-four patients had a mean age of 53 years (range 38-68, S.D.=8.6). VADs were implanted for 177.8 days (range 7-593 days, S.D.=151.1). Comparison of histologic scores of biopsies with explanted hearts showed the following: CN 1.33 (S.D.=1.4)/0.21 (S.D.=0.66; P<.001); CB: 2.1 (S.D.=0.93)/0.83 (S.D.=0.28; NS); MC: 0.88 (S.D.=1.19)/0.13 (S.D.=0.34; P<.01); IE: 1.71 (S.D.=1.27)/0.38 (S.D.=0.65; NS); fibrosis: 1.08 (S.D.=1.35)/1.75 (S.D.=1.26; NS); and MW: 1.50 (S.D.=1.22)/0.59 (S.D.=0.73; P<.01). Acquired aortic stenosis developed in six hearts, and one heart showed thrombotic occlusion of the left ventricular outflow tract below an aortic bioprosthesis. VAD significantly reduced the amount of CN, MC and MW in the left ventricle but may lead to acquired aortic stenosis of native aortic valves or total occlusive thrombosis of aortic prosthetic valves. Proximate cause of death was, most often, VAD related.
[Percutaneous stented pulmonary valve implantation].
Ersbøll, Mads; Søndergaard, Lars
2010-03-29
A number of congenital cardiac malformations involve the right ventricular outflow tract and are often treated with a biological valved conduit. The longevity of these valves is limited due to graft degeneration, which causes progressive valvular dysfunction and subsequently right ventricular failure. Due to the young age of these patients, repeat surgery can be expected and this has motivated the invention of the percutaneous stented valve implantation (PPVR). We retrospectively examined 13 patients (mean age 26 +/- 10 years) treated with PPVR between 2006 and 2008 at our institution. Indications for PPVR were conduit dysfunction with severe stenosis and/or regurgitation, reduced exercise capacity and right ventricular dilatation. In all patients, immediate haemodynamic improvement occurred with full valvular competence after PPVR. The pressure gradient was reduced from 43 (+/- 15) mmHg to 12 (+/- 7) mmHg (p = 0,05) in patients with combined regurgitation and stenosis and 47 (+/- 14) mmHg to 12 (+/- 2) mmHg (p = 0,05) in patients with isolated stenosis. At mean follow-up after 141 (+/- 140) days, no reintervention had been required. Significant haemodynamic and clinical improvement occurred after PPVR in all patients and no major complications occurred. PPVR remains a safe and minimally invasive treatment modality, and our study demonstrates that PPVR can be safely performed in a low volume setting.
Igarashi, Takashi; Tanji, Masahiro; Takahashi, Koki; Ishida, Keiichi; Sasaki, Satomi; Yokoyama, Hitoshi
2017-05-01
The aim of this study is to determine the predictors of secondary tricuspid regurgitation after aortic valve replacement for aortic stenosis. Seventy-one patients, who underwent aortic valve replacement for aortic stenosis at our institute from January 2006 to July 2011, were divided into two groups: an STR group, which included 15 patients with moderate or greater than moderate secondary tricuspid regurgitation at a follow-up visit and a control group. Echocardiography was performed before surgery, at discharge, and at a late follow-up visit (mean follow-up 36 ± 19 months, range 0-77). Preoperatively, the number of women (p < .01), body surface area (p < .001), and relative wall thickness (0.60 ± 0.15 vs 0.71 ± 0.13, p = .022) showed significant differences between the two groups. At a follow-up visit, moderate or severe mitral regurgitation (p = .0001) and severe diastolic dysfunction (p = .003) showed significant differences between the two groups. In the Cox regression analysis, moderate or severe mitral regurgitation at follow-up (p = .038, hazard ratio 4.394, 95% CI 1.085-17.791) was the only independent predictor of secondary tricuspid regurgitation. This study suggested that preoperative concentric myocardial hypertrophy and diastolic dysfunction were associated with development of the secondary tricuspid regurgitation at late follow-up.
Scharfschwerdt, Michael; Leonhard, Moritz; Lehmann, Judith; Richardt, Doreen; Goldmann, Helmut; Sievers, Hans-Hinrich
2016-05-01
Prosthetic replacement of the thoracic aorta with common Dacron prostheses impairs the aortic 'windkessel' and, in valve-sparing procedures, also aortic valve function. Elastic graft material may overcome these deficiencies. Fresh porcine aortas including the root were set up in a mock circulation before and after replacement of the ascending part with a novel vascular prosthesis providing elastic behaviours. In a first series (n = 14), haemodynamics and leaflet motions of the aortic valve were investigated and also cyclic changes of aortic dimensions at different levels of the root. In a second series (n = 7), intravascular pressure and dimensions of the proximal descending aorta were measured and the corresponding wall tension was calculated. Haemodynamics of the aortic valve remain comparable after replacement. Though the novel prosthesis does not feature such high distensibility as the native aorta, the dynamic of the root was significantly increased compared with common Dacron prostheses at the commissural level, preserving 'windkessel' function. Thus, wall tension of the residual aorta remained unchanged; nevertheless, maximum pressure-time differential dp/dt increased by 13%. The use of the novel elastic prosthesis for replacement of the ascending aorta seems to be beneficial, especially with regard to the preservation of the aortic windkessel. Further studies will be needed to clarify long-term utilization of the material in vivo. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Cardiac Imaging for Assessing Low-Gradient Severe Aortic Stenosis.
Clavel, Marie-Annick; Burwash, Ian G; Pibarot, Philippe
2017-02-01
Up to 40% of patients with aortic stenosis (AS) harbor discordant Doppler-echocardiographic findings, the most common of which is the presence of a small aortic valve area (≤1.0 cm 2 ) suggesting severe AS, but a low gradient (<40 mm Hg) suggesting nonsevere AS. The purpose of this paper is to present the role of multimodality imaging in the diagnostic and therapeutic management of this challenging entity referred to as low-gradient AS. Doppler-echocardiography is critical to determine the subtype of low-gradient AS: that is, classical low-flow, paradoxical low-flow, or normal-flow. Patients with low-flow, low-gradient AS generally have a worse prognosis compared with patients with high-gradient or with normal-flow, low-gradient AS. Patients with low-gradient AS and evidence of severe AS benefit from aortic valve replacement (AVR). However, confirmation of the presence of severe AS is particularly challenging in these patients and requires a multimodality imaging approach including low-dose dobutamine stress echocardiography and aortic valve calcium scoring by multidetector computed tomography. Transcatheter AVR using a transfemoral approach may be superior to surgical AVR in patients with low-flow, low-gradient AS. Further studies are needed to confirm the best valve replacement procedure and prosthetic valve for each category of low-gradient AS and to identify patients with low-gradient AS in whom AVR is likely to be futile. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Lucchese, Gianluca; Rossetti, Lucia; Faggian, Giuseppe; Luciani, Giovanni B
2016-10-01
Temporary tricuspid valve detachment improves the operative view of certain congenital ventricular septal defects (VSDs), but its long-term effects on tricuspid valve function are still debated. From 2002 through 2012, we performed a prospective study of 68 children (mean age, 1.28 ± 1.01 yr) who underwent transatrial closure of VSDs following temporary tricuspid valve detachment. Sixty patients had conoventricular and 8 had mid-muscular VSDs. All were in sinus rhythm. Seventeen patients had systemic pulmonary artery pressures. Preoperative echocardiograms showed trivial-to-mild tricuspid regurgitation in 62 patients and tricuspid dysplasia with severe regurgitation in 6 patients. Patients were clinically and echocardiographically monitored at 30 postoperative days, 3 months, 6 months, every 6 months thereafter for the first 2 years, and then once a year. No in-hospital or late death was observed at the median follow-up evaluation of 5.9 years. Mean intensive care unit and hospital stays were 1.6 ± 1.1 and 7.3 ± 2.7 days, respectively. Residual small VSDs occurred in 3 patients, and temporary atrioventricular block in one. After VSD repair, 62 patients (91%) had trivial or mild tricuspid regurgitation, and 6 moderate. Five of these last had severe tricuspid regurgitation preoperatively and had undergone additional tricuspid valve repair during the procedure. The grade of residual tricuspid regurgitation remained stable postoperatively, and no tricuspid stenosis was documented. All patients were in New York Heart Association class I at follow-up. Temporary tricuspid valve detachment is a simple and useful method for a complete visualization of certain VSDs without incurring substantial tricuspid dysfunction.
Rossetti, Lucia; Faggian, Giuseppe; Luciani, Giovanni B.
2016-01-01
Temporary tricuspid valve detachment improves the operative view of certain congenital ventricular septal defects (VSDs), but its long-term effects on tricuspid valve function are still debated. From 2002 through 2012, we performed a prospective study of 68 children (mean age, 1.28 ± 1.01 yr) who underwent transatrial closure of VSDs following temporary tricuspid valve detachment. Sixty patients had conoventricular and 8 had mid-muscular VSDs. All were in sinus rhythm. Seventeen patients had systemic pulmonary artery pressures. Preoperative echocardiograms showed trivial-to-mild tricuspid regurgitation in 62 patients and tricuspid dysplasia with severe regurgitation in 6 patients. Patients were clinically and echocardiographically monitored at 30 postoperative days, 3 months, 6 months, every 6 months thereafter for the first 2 years, and then once a year. No in-hospital or late death was observed at the median follow-up evaluation of 5.9 years. Mean intensive care unit and hospital stays were 1.6 ± 1.1 and 7.3 ± 2.7 days, respectively. Residual small VSDs occurred in 3 patients, and temporary atrioventricular block in one. After VSD repair, 62 patients (91%) had trivial or mild tricuspid regurgitation, and 6 moderate. Five of these last had severe tricuspid regurgitation preoperatively and had undergone additional tricuspid valve repair during the procedure. The grade of residual tricuspid regurgitation remained stable postoperatively, and no tricuspid stenosis was documented. All patients were in New York Heart Association class I at follow-up. Temporary tricuspid valve detachment is a simple and useful method for a complete visualization of certain VSDs without incurring substantial tricuspid dysfunction. PMID:27777518
Kong, William K F; Regeer, Madelien V; Ng, Arnold C T; McCormack, Louise; Poh, Kian Keong; Yeo, Tiong Cheng; Shanks, Miriam; Parent, Sarah; Enache, Roxana; Popescu, Bogdan A; Yip, James W; Ma, Lawrence; Kamperidis, Vasileios; van der Velde, Enno T; Mertens, Bart; Ajmone Marsan, Nina; Delgado, Victoria; Bax, Jeroen J
2017-03-01
This large multicenter, international bicuspid aortic valve (BAV) registry aimed to define the sex differences in prevalence, valve morphology, dysfunction (aortic stenosis/regurgitation), aortopathy, and complications (endocarditis and aortic dissection). Demographic, clinical, and echocardiographic data at first presentation of 1992 patients with BAV (71.5% men) were retrospectively analyzed. BAV morphology and valve function were assessed; aortopathy configuration was defined as isolated dilatation of the sinus of Valsalva or sinotubular junction, isolated dilatation of the ascending aorta distal to the sinotubular junction, or diffuse dilatation of the aortic root and ascending aorta. New cases of endocarditis and aortic dissection were recorded. There were no significant sex differences regarding BAV morphology and frequency of normal valve function. When presenting with moderate/severe aortic valve dysfunction, men had more frequent aortic regurgitation than women (33.8% versus 22.2%, P <0.001), whereas women were more likely to have aortic stenosis (34.5% versus 44.1%, P <0.001). Men had more frequently isolated dilatation of the sinus of Valsalva or sinotubular junction (14.2% versus 6.7%, P <0.001) and diffuse dilatation of the aortic root and ascending aorta (16.2% versus 7.3%, P <0.001) than women. Endocarditis (4.5% versus 2.5%, P =0.037) and aortic dissections (0.5% versus 0%, P <0.001) occurred more frequently in men. Although there is a male predominance among patients with BAV, men with BAV had more frequently moderate/severe aortic regurgitation at first presentation compared with women, whereas women presented more often with moderate/severe aortic stenosis compared with men. Furthermore, men had more frequent aortopathy than women. © 2017 American Heart Association, Inc.
Tsugu, Toshimitsu; Murata, Mitsushige; Iwanaga, Shiro; Kitamura, Yohei; Inoue, Soushin; Fukuda, Keiichi
2015-04-01
We present the rare case of a 76-year-old female with infective endocarditis (IE) caused by Candida glabrata. Immediately before developing the present infection, she developed IE with vegetation on the mitral annular calcification, which was caused by Streptococcus mitis and successfully treated with penicillin-G and gentamicin. However, her fever recurred, and she developed disseminated intravascular coagulation. Blood culture revealed C. glabrata, and echocardiography revealed new vegetation on the mitral valve. After 4 weeks of treatment with micafungin, prosthetic valve replacement was performed, followed by additional administration of micafungin for 4 weeks (total of 8 weeks). No relapse at 9 months after surgery has been observed. C. glabrata endocarditis is extremely rare and difficult to manage. Our case and review of past reported cases suggest that early diagnosis and initiation of treatment contribute to good prognosis of C. glabrata endocarditis.
Serratia endocarditis. A follow-up report.
Cooper, R; Mills, J
1980-02-01
Seventeen new cases of Serratia marcescens endocarditis observed in the San Francisco Bay Area since June 1974 are presented. Fifteen patients had a history of illicit intravenous drug use and four patients had prosthetic heart valves. Seven patients with infection of right-sided heart valves did well, although surgery was required in two for persistent fever or recurrent pulmonary emboli. Only three of ten patients with left-sided infection survived despite synergistic antibiotic combinations and high serum bactericidal titers. Fifteen isolates of Serratia from patients with endocarditis were serotyped, and none of these serotypes corresponded to the pigmented strain aerosolized by the US Army in the Bay Area in 1951. The isolation of the same Serratia strain from two patients and their shared injection paraphernalia provided insight into the pathogenesis of endocarditis in the intravenous drug user. A revised therapeutic approach to this difficult infection is presented.
Use of bovine pericardial tissue for aortic valve and aortic root replacement: long-term results.
Vrandecic, M; Gontijo Filho, B; Fantini, F; Barbosa, J; Martins, I; de Oliveira, O C; Martins, C; Max, R; Drumond, L; Oliveira, C; Ferrufino, A; Alcocer, E; Silva, J A; Vrandecic, E
1998-03-01
The study aimed to determine the clinical performance of bovine pericardial aldehyde-treated products alone or in combination with aortic leaflets of porcine origin. These included a composite porcine stentless aortic valve attached to a scalloped pericardial tube (BSAV), and valved and non-valved bovine pericardial conduits for use in left-sided heart lesions (BPG). For BSAV grafts, between January 1990 and August 1996, 163 patients (119 males) had their aortic valves replaced by SJM Biocor BASV. Mean age was 37.9 +/- 17.6 years (range: 1 to 76 years). Rheumatic heart disease sequelae (n = 72) and replacement of a prosthetic heart valve (n = 46) were predominant. Preoperative NYHA functional class showed 90 patients (55.2%) in class III and 50 (30.7%) in class IV. BPVC and NVPC grafts were used in 166 patients: acute aortic dissection was the main indication in 52 (31.3%) and chronic in 36 (21/7%). The ascending aorta was involved in 141 patients (84.9%); grafts were seldom used at other sites. In most patients the graft implanted was either a non-valved (n = 79) or a valved (n = 75) pericardial conduit. Twelve patients had a localized lesion and required a patch repair. For BASV grafts, the non-valve-related hospital mortality rate was 4.9%. There were 14.7% non-fatal complications with full recovery of all patients. Mean follow up in 141 patients was 3.0 +/- 1.4 years (range: 1 month to 7.2 years); 14 patients were lost to follow up. Late, non-conduit-related, mortality occurred in seven patients (4.9%). Eight patients underwent reoperation. The current clinical follow up of 127 patients has shown 118 (92.9%) with competent valves and nine (7.0%) with mild stable aortic insufficiency. For BPVC and NVPC grafts, hospital mortality rate was 16.9%, death being related to poor preoperative clinical condition. Postoperative follow up was accomplished in 125 patients; reoperation was necessary in seven patients. Histology showed good tissue preservation up to five years; echocardiography revealed satisfactory findings. No valved conduit had to be reoperated for valve or pericardial tissue wear. Clinical results of left-sided heterologous pericardial grafts have shown excellent performance over time. The BASV (over seven years) and BPVC and NVPC (eight years) have demonstrated superior results as aortic valves alone or in combination with a pericardial conduit.
Speckle tracking evaluation of right ventricular functions in children with sickle cell disease.
Tolba, Osama Abd Rab Elrasol; El-Shanshory, Mohamed Ramadan; El-Gamasy, Mohamed Abd Elaziz; El-Shehaby, Walid Ahmed
2017-01-01
Cardiac dysfunction is a risk factor for death in patients with sickle cell disease (SCD). Aim of the work is to evaluate the right ventricular systolic and diastolic functions by tissue Doppler and speckling tracking imaging in children with SCD. Thirty children with SCD and thirty controls were subjected to clinical, laboratory evaluations, and echocardiographic study using GE Vivid 7 (GE Medical System, Horten, Norway with a 3.5-MHz multifrequency transducer) including; Two-dimensional and tissue Doppler echocardiographic study (lateral tricuspid valve annulus peak E' velocity, lateral tricuspid valve annulus peak A' velocity, E'/A' ratio, isovolumetric relaxation time, lateral tricuspid valve annulus S' and septal S' waves and peak longitudinal systolic strain [PLSS] and time to PLSS) were done in six right ventricular segments. There was a significant decrease in right ventricular systolic and diastolic function in patients group when compared to controls. Children with SCD have impaired right ventricular systolic and diastolic functions when compared to healthy children with early evaluation of the systolic dysfunction by speckle tracking imaging technique.
Mitral valve repair: an echocardiographic review: Part 2.
Maslow, Andrew
2015-04-01
Echocardiographic imaging of the mitral valve before and immediately after repair is crucial to the immediate and long-term outcome. Prior to mitral valve repair, echocardiographic imaging helps determine the feasibility and method of repair. After the repair, echocardiographic imaging displays the new baseline anatomy, assesses function, and determines whether or not further management is necessary. Three-dimensional imaging has improved the assessment of the mitral valve and facilitates communication with the surgeon by providing the surgeon with an image that he/she might see upon opening up the atrium. Further advancements in imaging will continue to improve the understanding of the function and dysfunction of the mitral valve both before and after repair. This information will improve treatment options, timing of invasive therapies, and advancements of repair techniques to yield better short- and long-term patient outcomes. The purpose of this review was to connect the echocardiographic evaluation with the surgical procedure. Bridging the pre- and post-CPB imaging with the surgical procedure allows a greater understanding of mitral valve repair.
Emerging Transcatheter Options for Tricuspid Regurgitation
Kalra, Ankur; Uberoi, Angad S.; Latib, Azeem; Khera, Sahil; Little, Stephen H.; Bhatt, Deepak L.; Reardon, Michael J.; Kleiman, Neal S.; Barker, Colin M.
2017-01-01
Tricuspid regurgitation (TR) presents as either primary valve pathology or secondary to pulmonary or left-sided heart disease. Severe TR portends a worse prognosis independent of age, right ventricular size and function, severe left ventricular dysfunction, and increased pulmonary arterial pressures. Surgical treatment for TR has mostly been limited to patients undergoing mitral valve repair since those at high surgical risk are not candidates for traditional TR surgery. For these patients, minimally invasive techniques could be of great benefit, yet these techniques have been slow to develop because of the various anatomic and physiological aspects of the tricuspid valve apparatus. Several promising new techniques are currently undergoing clinical investigation, including caval valve implantation, percutaneous tricuspid annuloplasty techniques (Trialign, TriCinch, Cardioband), edge-to-edge repair with the MitraClip system, the FORMA device, and the GATE tricuspid Atrioventricular Valved Stent. Further evaluation of their safety and long-term efficacy is warranted prior to commercial approval and widespread adoption. PMID:29743996
Utilization of penile prosthesis and male incontinence prosthetics in Saudi Arabia.
Alwaal, Amjad; Al-Sayyad, Ahmad J
2017-01-01
Erectile dysfunction is a prevalent disease affecting over 50% of men between the ages of 40 and 70 years. Penile prosthesis represents the end of the line treatment when other less invasive therapies fail or are contraindicated. Male stress urinary incontinence can significantly diminish quality of life and lead to embarrassment and social withdrawal. Surgical therapies, such as male urethral slings and artificial urinary sphincters (AUS), are considered effective and safe treatments for male stress incontinence. No data exist on the utilization of penile prosthesis or male incontinence surgical treatment in Saudi Arabia. Generally, urological prosthetic surgery is performed either in private hospitals or in government hospitals. Our aim was to assess the trend of penile prosthesis and male incontinence device utilization in Saudi Arabia. We utilized sales' data of penile prosthetics, male slings, and AUS from the only two companies selling these devices in Saudi Arabia (AMS ® and Coloplast ® ), from January 2013 to December 2016. There were 2599 penile prosthesis implantation procedures done in the study period, with 67% of them performed in private institutions. There was a progressively increased use of penile prosthetics which nearly doubled from 2013 to 2016. The main type of prosthesis utilized was the semirigid type 70% versus 11% of the 2-piece inflatable and 17% of the 3-piece inflatable device. Only 10 slings and 31 AUS were inserted during the same study period. There is an increased utilization of penile prosthetics in Saudi Arabia. The private sector performs the majority of penile prosthesis procedures, and most of them are of the semirigid type. The governmental sector is more likely to perform inflatable penile prosthesis and male incontinence device procedures. Male incontinence prosthetics' use is very limited in Saudi Arabia.
Fluid-Structure Model of Lymphatic Valve and Vessel
NASA Astrophysics Data System (ADS)
Wolf, Ki; Ballard, Matthew; Nepiyushchikh, Zhanna; Razavi, Mohammad; Dixon, Brandon; Alexeev, Alexander
The lymphatic system is a part of the circulatory system that performs a range of important functions such as transportation of interstitial fluid, fatty acid, and immune cells. The lymphatic vessels are composed of contractile walls to pump lymph against adverse pressure gradient and lymphatic valves that prevent back flow. Despite the importance of lymphatic system, the contribution of mechanical and geometric changes of lymphatic valves and vessels in pathologies of lymphatic dysfunction, such as lymphedema, is not well understood. We developed a coupled fluid-solid computational model to simultaneously simulate a lymphatic vessel, valve, and flow. A lattice Boltzmann model is used to represent the fluid component, while lattice spring model is used for the solid component of the lymphatic vessel, whose mechanical properties are derived experimentally. Behaviors such as lymph flow pattern and lymphatic valve performance against backflow and adverse pressure gradient under varied parameters of lymphatic valve and vessel geometry and mechanical properties are investigated to provide a better insight into the dynamics of lymphatic vessels, valves, and system and give insight into how they might fail in disease. NSF CMMI-1635133.
Gerckens, Ulrich; Tamburino, Corrado; Bleiziffer, Sabine; Bosmans, Johan; Wenaweser, Peter; Brecker, Stephen; Guo, Jia; Linke, Axel
2017-01-01
Abstract Aims The ADVANCE study was designed to evaluate the safety and effectiveness of transcatheter aortic valve implantation (TAVI) with a self-expanding bioprosthesis in real-world patients with symptomatic, severe aortic stenosis at high surgical risk for valve replacement. Methods and results Study participants were enrolled from 44 experienced centres in 12 countries. Patient eligibility, treatment approach, and choice of anaesthesia were determined by the local Heart Team. The study was 100% monitored, and adverse events were adjudicated by an independent clinical events committee using Valve Academic Research Consortium (VARC-1) criteria. There were 1015 patients enrolled with 996 attempted TAVI procedures. Mean age was 81 years, and mean logistic EuroSCORE was 19.3 ± 12.3%. Five-year follow-up was available on 465 (46.7%) patients. At 5 years, the rate of all-cause mortality was 50.7% (95% confidence interval: 46.7%, 54.5%), and the rate of major stroke was 5.4%. Haemodynamic measures remained consistent for paired patients with a mean aortic valve gradient of 8.8 ± 4.4 mmHg (n = 198) and an effective orifice area of 1.7 ± 0.4 cm2 (n = 123). Aortic regurgitation (AR) decreased over time and among paired patients dropped from 12.8% to 8.0% moderate AR at 5 years (n = 125). Of the 860 patients with echocardiographic data or a reintervention after 30 days, there were 22 (2.6%) patients meeting the VARC-2 criteria for valve dysfunction and 10 (1.2%) patients with a reintervention >30 days. Conclusion Five-year results in real-world, elderly, high-risk patients undergoing TAVI with a self-expanding bioprosthesis provided evidence for continued valve durability with low rates of reinterventions and haemodynamic valve dysfunction. Trial registration ClinicalTrials.gov, NCT01074658. PMID:28633375
Chemoprophylaxis in cardiac and orthopedic surgery: comparison of cephalothin and cephapirin.
Bryant, R E; Hartstein, A I; Starr, A; Beals, R K
1982-09-01
In a retrospective sequential study we determined the rate of infection occurring despite cephalothin or cephapirin chemoprophylaxis in orthopedic and cardiac surgery done from 1973 to 1977. The incidence of infection after prosthetic hip placement or open reduction of hip fracture was 3.4% and 1.0% in patients receiving cephalothin or cephapirin, respectively. The infection rate after prosthetic heart valve implantation was 3.5% in those receiving cephalothin and 1.6% in those receiving cephapirin. There was no significant difference in infection rate, duration of fever greater than or equal to 38.0 C, or length of postoperative hospitalization. The efficacy of selected antistaphylococcal antibiotics in preventing colonization of human fibrin clots by staphylococci was studied. Although cephapirin was effective at lower concentration, the activity of cephalothin and cephapirin was comparable. Cephalothin and cephapirin have equivalent chemoprophylactic activity by clinical and microbiological criteria, permitting cost to be used as a basis for choosing between these antibiotics.
Schubmehl, Heidi B; Swartz, Michael F; Atallah-Yunes, Nader; Wittlieb-Weber, Carol; Pratt, Rebecca E; Alfieris, George M
2017-01-01
The goals following pulmonary valve replacement (PVR) are to optimize right ventricular hemodynamics and minimize the need for subsequent reoperations on the right ventricular outflow tract. We hypothesized PVR using a xenograft valved conduit would result in superior freedom from reoperation with sustained improvement in right ventricular chamber dimensions. Xenograft valved conduits placed in patients aged >16 years were reviewed from 2000 to 2010 to allow for a 5-year minimum follow-up. Preoperative, one-year, and the most recent echocardiograms quantified right ventricular chamber dimensions, corresponding Z scores, and prosthetic valve function. Magnetic resonance imaging (MRI) studies compared preoperative and follow-up right ventricular volumes. A total of 100 patients underwent PVR at 24 (19-34) years. Freedom from reintervention was 100% at 10 years. At most recent follow-up, only one patient had greater than mild pulmonary insufficiency. The one-year (17.3 ± 7.2 mm Hg; P < .01) and most recent follow-up (18.6 ± 9.8 mm Hg; P < .01) Doppler-derived right ventricular outflow tract gradients remained significantly lower than preoperative measurements (36.7 ± 27.0 mm Hg). Similarly, right ventricular basal diameter, basal longitudinal diameter, and the corresponding Z scores remained lower at one year and follow-up from preoperative measurements. From 34 MRI studies, the right ventricular end-diastolic indexed volume (161.7 ± 58.5 vs 102.9 ± 38.3; P < .01) and pulmonary regurgitant fraction (38.0% ± 15.9% vs 0.8% ± 3.3%; P < .01) were significantly lower at 7.1 ± 3.4 years compared to the preoperative levels. Use of a xenograft valved conduit for PVR results in excellent freedom from reoperation with sustained improvement in right ventricular dimensions at an intermediate-term follow-up.
Walther, Thomas; Thielmann, Matthias; Kempfert, Joerg; Schroefel, Holger; Wimmer-Greinecker, Gerhard; Treede, Hendrik; Wahlers, Thorsten; Wendler, Olaf
2012-08-01
Transapical (TA) aortic valve implantation (AVI) has evolved as an alternative procedure for high-risk patients. We evaluated the second-generation SAPIEN XT™ prosthesis in a prospective multicentre clinical trial. A total of 150 patients (age: 81.6 ± 5.8 years; 40.7% female) were included. Prosthetic valves (diameter: 23 mm (n = 36), 26 mm (n = 57) and 29 mm (n = 57)) were implanted. The ASCENDRA-II™ modified delivery system was used in the smaller sizes. Mean logistic EuroSCORE was 24.3 ± 7.0%, and mean STS score 7.5 ± 4.4%. All patients gave written informed consent. Off-pump AVI was performed using femoral arterial and venous access wires as a safety net. All but two patients received TA-AVI, as planned. The 29-mm valve showed similar function as the values of two other diameters did. Three patients (2%) required temporary cardiopulmonary bypass support. Postoperative complications included renal failure requiring long-term dialysis in four, bleeding requiring rethoracotomy in four, respiratory complication requiring reintubation in eight and sepsis in four patients, respectively. Thirty-day mortality was 13 (8.7%) for the total cohort and 2/57 (3.5%) for patients receiving the 29-mm valve, respectively. Echocardiography at discharge showed none or trivial aortic incompetence (AI) in 71% and mild-AI in 22% of the patients. Post-implantation AI was predominantly paravalvular and ≥ 2+ in 7% of patients. One patient required reoperation for AI within 30 days. The PREVAIL TA multicentre trial demonstrates good functionality and good outcomes for TA-AVI, using the SAPIEN XT™ prosthesis and its second-generation ASCENDRA-II™ delivery system, as well successful introduction of the 29-mm SAPIEN XT™ valve for the benefit of high-risk elderly patients.
Will Catheter Interventions Replace Surgery for Valve Abnormalities?
O’Byrne, Michael L; Gillespie, Matthew J
2015-01-01
Purpose of Review Catheter-based valve technologies have evolved rapidly over the last decade. Transcatheter aortic valve replacement (TAVR) has become a routine procedure in high-risk adult patients with calcific aortic stenosis. In patients with congenital heart disease (CHD), transcatheter pulmonary valve replacement represents a transformative technology for right ventricular outflow tract dysfunction with the potential to expand to other indications. This review aims to summarize 1) the current state of the art for transcatheter valve replacement (TVR) in CHD, 2) the expanding indications for TVR, and 3) the technological obstacles to optimizing TVR. Recent findings Multiple case series have demonstrated that TVR with the Melody transcatheter pulmonary valve in properly selected patients is safe, effective, and durable in short-term follow-up. The Sapien transcatheter heart valve represents an alternative device with similar safety and efficacy in limited studies. Innovative use of current valves has demonstrated the flexibility of TVR, while highlighting the need for devices to address the broad range of post-operative anatomies either with a single device or strategies to prepare the outflow tract for subsequent device deployment. Summary The potential of TVR has not been fully realized, but holds promise in treatment of CHD. PMID:24281347
Olivieri, Laura J.; Baba, Ridhwan Y.; Arai, Andrew E.; Bandettini, W. Patricia; Rosing, Douglas R.; Bakalov, Vladimir; Sachdev, Vandana; Bondy, Carolyn A.
2014-01-01
Background Congenital aortic valve fusion is associated with aortic dilation, aneurysm and rupture in girls and women with Turner syndrome (TS). Our objective was to characterize aortic valve structure in subjects with TS, and determine the prevalence of aortic dilation and valve dysfunction associated with different types of aortic valves. Methods and Results The aortic valve and thoracic aorta were characterized by cardiovascular magnetic resonance imaging in 208 subjects with TS in an IRB-approved natural history study. Echocardiography was used to measure peak velocities across the aortic valve, and the degree of aortic regurgitation. Four distinct valve morphologies were identified: tricuspid aortic valve (TAV) 64%(n=133), partially fused aortic valve (PF) 12%(n=25), bicuspid aortic valve (BAV) 23%(n=47), and unicuspid aortic valve (UAV) 1%(n=3). Age and body surface area (BSA) were similar in the 4 valve morphology groups. There was a significant trend, independent of age, towards larger BSA-indexed ascending aortic diameters (AADi) with increasing valve fusion. AADi were (mean +/− SD) 16.9 +/− 3.3 mm/m2, 18.3 +/− 3.3 mm/m2, and 19.8 +/− 3.9 mm/m2 (p<0.0001) for TAV, PF and BAV+UAV respectively. PF, BAV, and UAV were significantly associated with mild aortic regurgitation and elevated peak velocities across the aortic valve. Conclusions Aortic valve abnormalities in TS occur with a spectrum of severity, and are associated with aortic root dilation across age groups. Partial fusion of the aortic valve, traditionally regarded as an acquired valve problem, had an equal age distribution and was associated with an increased AADi. PMID:24084490
Martins, Carlo de Oliveira; Demarchi, Lea; Ferreira, Frederico Moraes; Pomerantzeff, Pablo Maria Alberto; Brandao, Carlos; Sampaio, Roney Orismar; Spina, Guilherme Sobreira; Kalil, Jorge; Cunha-Neto, Edecio; Guilherme, Luiza
2017-01-01
Autoimmune inflammatory reactions leading to rheumatic fever (RF) and rheumatic heart disease (RHD) result from untreated Streptococcus pyogenes throat infections in individuals who exhibit genetic susceptibility. Immune effector mechanisms have been described that lead to heart tissue damage culminating in mitral and aortic valve dysfunctions. In myxomatous valve degeneration (MXD), the mitral valve is also damaged due to non-inflammatory mechanisms. Both diseases are characterized by structural valve disarray and a previous proteomic analysis of them has disclosed a distinct profile of matrix/structural proteins differentially expressed. Given their relevance in organizing valve tissue, we quantitatively evaluated the expression of vimentin, collagen VI, lumican, and vitronectin as well as performed immunohistochemical analysis of their distribution in valve tissue lesions of patients in both diseases. We identified abundant expression of two isoforms of vimentin (45 kDa, 42 kDa) with reduced expression of the full-size protein (54 kDa) in RHD valves. We also found increased vitronectin expression, reduced collagen VI expression and similar lumican expression between RHD and MXD valves. Immunohistochemical analysis indicated disrupted patterns of these proteins in myxomatous degeneration valves and disorganized distribution in rheumatic heart disease valves that correlated with clinical manifestations such as valve regurgitation or stenosis. Confocal microscopy analysis revealed a diverse pattern of distribution of collagen VI and lumican into RHD and MXD valves. Altogether, these results demonstrated distinct patterns of altered valve expression and tissue distribution/organization of structural/matrix proteins that play important pathophysiological roles in both valve diseases.
18F-FDG positron emission tomography/computed tomography in infective endocarditis.
Salomäki, Soile Pauliina; Saraste, Antti; Kemppainen, Jukka; Bax, Jeroen J; Knuuti, Juhani; Nuutila, Pirjo; Seppänen, Marko; Roivainen, Anne; Airaksinen, Juhani; Pirilä, Laura; Oksi, Jarmo; Hohenthal, Ulla
2017-02-01
The diagnosis of infective endocarditis (IE), especially the diagnosis of prosthetic valve endocarditis (PVE) is challenging since echocardiographic findings are often scarce in the early phase of the disease. We studied the use of 2-[ 18 F]fluoro-2-deoxy-D-glucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) in IE. Sixteen patients with suspected PVE and 7 patients with NVE underwent visual evaluation of 18 F-FDG-PET/CT. 18 F-FDG uptake was measured also semiquantitatively as maximum standardized uptake value (SUV max ) and target-to-background ratio (TBR). The modified Duke criteria were used as a reference. There was strong, focal 18 F-FDG uptake in the area of the affected valve in all 6 cases of definite PVE, in 3 of 5 possible PVE cases, and in 2 of 5 rejected cases. In all patients with definite PVE, SUV max of the affected valve was higher than 4 and TBR higher than 1.8. In contrast to PVE, only 1 of 7 patients with NVE had uptake of 18 F-FDG by PET/CT in the valve area. Embolic infectious foci were detected in 58% of the patients with definite IE. 18 F-FDG-PET/CT appears to be a sensitive method for the detection of paravalvular infection associated with PVE. Instead, the sensitivity of PET/CT is limited in NVE.
Lacalzada-Almeida, Juan; De la Rosa-Hernández, Alejandro; Izquierdo-Gómez, María Manuela; García-Niebla, Javier; Hernández-Betancor, Iván; Bonilla-Arjona, Juan Alfonso; Barragán-Acea, Antonio; Laynez-Cerdeña, Ignacio
2018-01-01
A 61-year-old male with a prosthetic St Jude aortic valve size 24 presented with heart failure symptoms and minimal-effort angina. Eleven months earlier, the patient had undergone cardiac surgery because of an aortic root dilatation and bicuspid aortic valve with severe regurgitation secondary to infectious endocarditis by Coxiela burnetii and coronary artery disease in the left circumflex coronary artery. Then, a prosthesis valve and a saphenous bypass graft to the left circumflex coronary artery were placed. The patient was admitted to the Cardiology Department of Hospital Universitario de Canarias, Tenerife, Spain and a transthoracic echocardiography was performed that showed severe paraprosthetic aortic regurgitation and an aortic pseudoaneurysm. The 64-slice multidetector computed tomography confirmed the pseudoaneurysm, originating from the right sinus of Valsalva, with a compression of the native right coronary artery and a normal saphenous bypass graft. On the basis of these findings, we performed surgical treatment with a favorable postoperative evolution. In our case, results from complementary cardiac imaging techniques were crucial for patient management. The multidetector computed tomography allowed for a confident diagnosis of an unusual mechanism of coronary ischemia.
Gansera, Laura Sophie; Eszlari, Edgar; Deutsch, Oliver; Eichinger, Walter Benno; Gansera, Brigitte
2016-01-01
To discuss the dilemma of adequate decision making in patients with intravenous drug abuse and recurrent valve prosthesis infections or in patients with positive HIV or hepatitis C status. Ethical, social, and economic considerations, not only in terms of technical feasibility but also in terms of unpromising results and aspects of resources, are discussed. Thoughts are presented about the legitimation of cardiac surgery centers refusing to perform surgery in high-risk patients with HIV or hepatitis C infections. Presentation of six cases for discussion. Three patients were addicted to intravenous drugs and had recurrent prosthetic valve endocarditis, and the other three patients had either paravalvular leakage of a mitral valve prosthesis or acute aortic dissection or coronary artery disease. Five of these patients suffered from HIV/AIDS and infective hepatitis C. Four of these patients were refused by other centers due to high risk or a lack of capacity. All six patients were operated during 2013. Mortality was 17%. Decision making in noncompliant drug addicts with recurrent prosthesis infection and in HIV-positive patients leads beyond surgical challenges to ethical and economic considerations. Georg Thieme Verlag KG Stuttgart · New York.
[Bacillus cereus endocarditis and a probable cutaneous gateway].
Soudet, S; Becquart, C; Dezoteux, F; Faure, K; Staumont-Salle, D; Delaporte, E
2017-01-01
Bacillus cereus is a ubiquitous telluric organism. B. cereus endocarditis is a rare condition seen mostly in prosthetic heart valves and among intravenous drug users. We report a new case of a patient without risk factors and with a good clinical outcome not requiring valve replacement. In October 2014, a 50-year-old woman was referred to the dermatology department of Lille University Hospital for lower-limb wounds developing 6 months earlier. She presented fever without clinical signs of infection, except for the lower-limbs wounds. Blood cultures revealed the presence of B. cereus. Transesophageal echocardiography was performed and revealed two foci of aortic valve vegetation with a diameter of 5mm. After bacterial sensitivity testing, rifampicin and levofloxacin treatment was given for six weeks, with complete remission. A skin graft was performed and good improvement was seen. Nineteen cases of B. cereus endocarditis have been described previously, only one of which was without risk factors. We described a case of complete remission after a 6-week course of antibiotics. Our case demonstrates that BC should not be considered as a blood culture contamination, and that treatment may be complex due to antibiotic resistance. Copyright © 2016 Elsevier Masson SAS. All rights reserved.