Sample records for proteinogram reference interval

  1. Biometric values, C-reactive protein, and proteinogram of healthy blonde capuchin (Sapajus flavius) kept in northeast of Brazil.

    PubMed

    Mota, Stéphanie Machado; Ferreira, Adriano Fernandes; Azevedo, Jair; Nery, Thiago Lopes; Zermiani, Fabiana; Queiroga, Felisbina Luisa

    2016-12-01

    Sapajus flavius is a species of capuchin monkey classified as critically endangered. Studies related to their biometric values are scarce with incomplete external measurement reports available from only four specimens. Moreover, information regarding proteinogram is limited with no reference to C-reactive protein (CRP) and globulin fractions for this species. Biometric values, CRP, and proteinogram were determined for 12 clinically healthy S. flavius, kept in captivity in João Pessoa, Brazil. The measured values in biometric parameters present a tendency to be higher in males. The CRP mean values from 12 S. flavius were 1.2±0.2 mg/dL. For albumin, alpha, beta, and gamma globulin fraction parameters, the reference interval was calculated. Authors believe that with certain limitations, results obtained can be helpful for the populations in the wild, which could be of great aid in detecting unhealthy individuals and therefore contributing to the conservation of this species. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Studies on proteinograms in dermatorphytes by disc electrophoresis. Part 2: Protein bands of keratinophilic fungi

    NASA Technical Reports Server (NTRS)

    Danev, P.; Balabanov, V.; Friedrich, E.

    1983-01-01

    Disc electrophoresis studies on keratinophili fungi demonstrated corresponding proteinograms in morphologically homogeneous strains of the same species, but different in different species of one and the same genus.

  3. Studies of proteinograms in dermatophytes by disc electrophoresis. 1. Protein bands in relation to growth phase

    NASA Technical Reports Server (NTRS)

    Danev, P.; Friedrich, E.; Balabanov, V.

    1983-01-01

    Homogenates were prepared from various growth phases of Microsporum gypseum grown on different amino acids as the nitrogen source. When analyzed on 7.5% polyacrylamide disc gels, the water-soluble proteins in these homogenates gave essentially identical banding patterns.

  4. Serum of Blood Separation by Means of Dynamic Electrochromatography in a Centrifugal and Electromagnetic Gradient.

    PubMed

    Jan Dyszkiewicz, Andrzej

    2014-01-01

    The paper presents the dynamic association of several gradients of separation with electrophoresis and the laboratory implementation of a prototype device for dynamic electrochromatography in a centrifugal and electromagnetic gradient (DECGOE), based on patent PL171643. The object of the study was to compare the separation capacity and repeatability of the location of edge parameters (xx(1), yy(1), d) of the contours of a proteinogram fraction for conventional electrophoresis (EF), radial SR-DECGOE separation and three variants of radial-transverse SR-SPM, SR-SPE, SRSPRRM distribution as well as the reproducibility of the following prototype parameters: PV(1), PV(2), PV(3)[V] potentials, PV(3)[F] frequency, ω(1) and ω(2) rotational speed, MC mixer chamber buffer [pH] and volume[ml], and B [T] magnetic induction. Human blood serum was used in the study, 50 samples for each separation type. The highest rate of fraction formation was registered for the SR-SPRRM (8,07/s) variant. The percentage values of standard deviations for the edge parameters of proteinograms were the lowest for conventional electrophoresis (EF), slightly higher for radial distribution SR, while among the radial-transverse separations, the highest accuracy was obtained for the SR-SPRRM variant.

  5. [Pathogenetic grounds of trophological impact of chronic pancreatitis complex therapy].

    PubMed

    Babinets', L S; Halabits'ka, I M; Botsiuk, N Ie; Riabokon', S S

    2014-11-01

    In chronic pancreatitis patients was found persistent state of oxidative stress on the level of malonic aldehyde, which ran against the lowered levels of antioxidant enzymatic and non-enzymatic composition, and it has been found in the state of hypoproteinemia proteinogram indices (P < 0.05). The use of complex treatment of patients with chronic pancreatitis multivitamin-aminoacid drug Moriamin forte contributes to a significant regression effects oxidative stress and reduces the effects of hypoproteinemia (P < 0.05).

  6. National Survey of Adult and Pediatric Reference Intervals in Clinical Laboratories across Canada: A Report of the CSCC Working Group on Reference Interval Harmonization.

    PubMed

    Adeli, Khosrow; Higgins, Victoria; Seccombe, David; Collier, Christine P; Balion, Cynthia M; Cembrowski, George; Venner, Allison A; Shaw, Julie

    2017-11-01

    Reference intervals are widely used decision-making tools in laboratory medicine, serving as health-associated standards to interpret laboratory test results. Numerous studies have shown wide variation in reference intervals, even between laboratories using assays from the same manufacturer. Lack of consistency in either sample measurement or reference intervals across laboratories challenges the expectation of standardized patient care regardless of testing location. Here, we present data from a national survey conducted by the Canadian Society of Clinical Chemists (CSCC) Reference Interval Harmonization (hRI) Working Group that examines variation in laboratory reference sample measurements, as well as pediatric and adult reference intervals currently used in clinical practice across Canada. Data on reference intervals currently used by 37 laboratories were collected through a national survey to examine the variation in reference intervals for seven common laboratory tests. Additionally, 40 clinical laboratories participated in a baseline assessment by measuring six analytes in a reference sample. Of the seven analytes examined, alanine aminotransferase (ALT), alkaline phosphatase (ALP), and creatinine reference intervals were most variable. As expected, reference interval variation was more substantial in the pediatric population and varied between laboratories using the same instrumentation. Reference sample results differed between laboratories, particularly for ALT and free thyroxine (FT4). Reference interval variation was greater than test result variation for the majority of analytes. It is evident that there is a critical lack of harmonization in laboratory reference intervals, particularly for the pediatric population. Furthermore, the observed variation in reference intervals across instruments cannot be explained by the bias between the results obtained on instruments by different manufacturers. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  7. CLSI-based transference of CALIPER pediatric reference intervals to Beckman Coulter AU biochemical assays.

    PubMed

    Abou El Hassan, Mohamed; Stoianov, Alexandra; Araújo, Petra A T; Sadeghieh, Tara; Chan, Man Khun; Chen, Yunqi; Randell, Edward; Nieuwesteeg, Michelle; Adeli, Khosrow

    2015-11-01

    The CALIPER program has established a comprehensive database of pediatric reference intervals using largely the Abbott ARCHITECT biochemical assays. To expand clinical application of CALIPER reference standards, the present study is aimed at transferring CALIPER reference intervals from the Abbott ARCHITECT to Beckman Coulter AU assays. Transference of CALIPER reference intervals was performed based on the CLSI guidelines C28-A3 and EP9-A2. The new reference intervals were directly verified using up to 100 reference samples from the healthy CALIPER cohort. We found a strong correlation between Abbott ARCHITECT and Beckman Coulter AU biochemical assays, allowing the transference of the vast majority (94%; 30 out of 32 assays) of CALIPER reference intervals previously established using Abbott assays. Transferred reference intervals were, in general, similar to previously published CALIPER reference intervals, with some exceptions. Most of the transferred reference intervals were sex-specific and were verified using healthy reference samples from the CALIPER biobank based on CLSI criteria. It is important to note that the comparisons performed between the Abbott and Beckman Coulter assays make no assumptions as to assay accuracy or which system is more correct/accurate. The majority of CALIPER reference intervals were transferrable to Beckman Coulter AU assays, allowing the establishment of a new database of pediatric reference intervals. This further expands the utility of the CALIPER database to clinical laboratories using the AU assays; however, each laboratory should validate these intervals for their analytical platform and local population as recommended by the CLSI. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  8. Reference Intervals of Common Clinical Chemistry Analytes for Adults in Hong Kong.

    PubMed

    Lo, Y C; Armbruster, David A

    2012-04-01

    Defining reference intervals is a major challenge because of the difficulty in recruiting volunteers to participate and testing samples from a significant number of healthy reference individuals. Historical literature citation intervals are often suboptimal because they're be based on obsolete methods and/or only a small number of poorly defined reference samples. Blood donors in Hong Kong gave permission for additional blood to be collected for reference interval testing. The samples were tested for twenty-five routine analytes on the Abbott ARCHITECT clinical chemistry system. Results were analyzed using the Rhoads EP evaluator software program, which is based on the CLSI/IFCC C28-A guideline, and defines the reference interval as the 95% central range. Method specific reference intervals were established for twenty-five common clinical chemistry analytes for a Chinese ethnic population. The intervals were defined for each gender separately and for genders combined. Gender specific or combined gender intervals were adapted as appropriate for each analyte. A large number of healthy, apparently normal blood donors from a local ethnic population were tested to provide current reference intervals for a new clinical chemistry system. Intervals were determined following an accepted international guideline. Laboratories using the same or similar methodologies may adapt these intervals if deemed validated and deemed suitable for their patient population. Laboratories using different methodologies may be able to successfully adapt the intervals for their facilities using the reference interval transference technique based on a method comparison study.

  9. Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China.

    PubMed

    Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li'an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling

    2016-03-01

    A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box-Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China.

  10. Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China

    PubMed Central

    Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li’an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling

    2016-01-01

    Abstract A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box–Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China. PMID:26945390

  11. Uptake of recommended common reference intervals for chemical pathology in Australia.

    PubMed

    Jones, Graham Rd; Koetsier, Sabrina

    2017-05-01

    Background Reference intervals are a vital part of reporting numerical pathology results. It is known, however, that variation in reference intervals between laboratories is common, even when analytical methods support common reference intervals. In response to this, in Australia, the Australasian Association of Clinical Biochemists together with the Royal College of Pathologists of Australasia published in 2014 a set of recommended common reference intervals for 11 common serum analytes (sodium, potassium, chloride, bicarbonate, creatinine male, creatinine female, calcium, calcium adjusted for albumin, phosphate, magnesium, lactate dehydrogenase, alkaline phosphatase and total protein). Methods Uptake of recommended common reference intervals in Australian laboratories was assessed using data from four annual cycles of the RCPAQAP reference intervals external quality assurance programme. Results Over three years, from 2013 to 2016, the use of the recommended upper and lower reference limits has increased from 40% to 83%. Nearly half of the intervals in use by enrolled laboratories in 2016 have been changed in this time period, indicating an active response to the guidelines. Conclusions These data support the activities of the Australasian Association of Clinical Biochemists and Royal College of Pathologists of Australasia in demonstrating a change in laboratory behaviour to reduce unnecessary variation in reference intervals and thus provide a consistent message to doctor and patients irrespective of the laboratory used.

  12. First Definition of Reference Intervals of Liver Function Tests in China: A Large-Population-Based Multi-Center Study about Healthy Adults

    PubMed Central

    Zhang, Chuanbao; Guo, Wei; Huang, Hengjian; Ma, Yueyun; Zhuang, Junhua; Zhang, Jie

    2013-01-01

    Background Reference intervals of Liver function tests are very important for the screening, diagnosis, treatment, and monitoring of liver diseases. We aim to establish common reference intervals of liver function tests specifically for the Chinese adult population. Methods A total of 3210 individuals (20–79 years) were enrolled in six representative geographical regions in China. Analytes of ALT, AST, GGT, ALP, total protein, albumin and total bilirubin were measured using three analytical systems mainly used in China. The newly established reference intervals were based on the results of traceability or multiple systems, and then validated in 21 large hospitals located nationwide qualified by the National External Quality Assessment (EQA) of China. Results We had been established reference intervals of the seven liver function tests for the Chinese adult population and found there were apparent variances of reference values for the variables for partitioning analysis such as gender(ALT, GGT, total bilirubin), age(ALP, albumin) and region(total protein). More than 86% of the 21 laboratories passed the validation in all subgroup of reference intervals and overall about 95.3% to 98.8% of the 1220 validation results fell within the range of the new reference interval for all liver function tests. In comparison with the currently recommended reference intervals in China, the single side observed proportions of out of range of reference values from our study for most of the tests deviated significantly from the nominal 2.5% such as total bilirubin (15.2%), ALP (0.2%), albumin (0.0%). Most of reference intervals in our study were obviously different from that of other races. Conclusion These used reference intervals are no longer applicable for the current Chinese population. We have established common reference intervals of liver function tests that are defined specifically for Chinese population and can be universally used among EQA-approved laboratories located all over China. PMID:24058449

  13. Serum TSH reference interval in healthy Finnish adults using the Abbott Architect 2000i Analyzer.

    PubMed

    Schalin-Jäntti, Camilla; Tanner, Pirjo; Välimäki, Matti J; Hämäläinen, Esa

    2011-07-01

    Current serum TSH reference intervals have been criticized as they were established from unselected background populations. A special concern is that the upper limit, which defines subclinical hypothyroidism, is too high. The objective was to redefine the TSH reference interval in the adult Finnish population. The current reference interval for the widely used Abbott Architect method in Finland is 0.4-4.0 mU/L. Serum TSH and free T4 concentrations were derived from 606 healthy, non-pregnant, 18-91-year-old Finns from the Nordic Reference Interval Project (NORIP) and the possible effects of age, sex and thyroid peroxidase antibody (TPOAb) status were evaluated. After excluding TPOAb-positive subjects and outliers, a reference population of 511 subjects was obtained. In the reference population, no statistically significant gender- or age-specific differences in mean TSH (1.55 ± 3.30 mU/L) or TSH reference intervals were observed. The new reference interval was 0.5-3.6 mU/L (2.5th-97.5th percentiles). The current upper TSH reference limit is 10% too high. A TSH > 3.6 mU/L, confirmed with a repeat TSH sampling, may indicate subclinical hypothyroidism. Differences in ethnicity, regional iodine-intake and analytical methods underline the need for redefining the TSH reference interval in central laboratories in different countries.

  14. Comprehensive haematological indices reference intervals for a healthy Omani population: First comprehensive study in Gulf Cooperation Council (GCC) and Middle Eastern countries based on age, gender and ABO blood group comparison.

    PubMed

    Al-Mawali, Adhra; Pinto, Avinash Daniel; Al-Busaidi, Raiya; Al-Lawati, Rabab H; Morsi, Magdi

    2018-01-01

    Reference intervals for venous blood parameters differs with age, gender, geographic region, and ethnic groups. Hence local laboratory reference intervals are important to improve the diagnostic accuracy of health assessments and diseases. However, there have been no comprehensive published reference intervals established in Oman, the Gulf Cooperation Council or Middle Eastern countries. Hence, the aim of this study was to establish reference intervals for full blood count in healthy Omani adults. Venous blood specimens were collected from 2202 healthy individuals aged 18 to 69 years from January 2012 to April 2017, and analysed by Sysmex XS-1000i and Cell-Dyn Sapphire automated haematology analysers. Results were statistically analysed and compared by gender, age, and ABO blood group. The lower and upper reference limits of the haematology reference intervals were established at the 2.5th and 97.5th percentiles respectively. Reference intervals were calculated for 17 haematology parameters which included red blood cell, white blood cell, and platelet parameters. Red blood cell (RBC), haemoglobin (HGB), haematocrit (HCT), platelet and platelet haematocrit counts of the healthy donors were significantly different between males and females at all ages (p < 0.05), with males having higher mean values of RBC, HGB and HCT than females. Other complete blood count parameters showed no significant differences between genders, age groups, instruments, or blood groups. Our study showed a lower haemoglobin limit for the normal reference interval in males and females than the currently used in Oman. Data from this study established specific reference intervals which could be considered for general use in Oman. The differences in haematology reference intervals highlights the necessity to establish reference intervals for venous blood parameters among the healthy population in each country or at least in each region.

  15. Pediatric reference value distributions and covariate-stratified reference intervals for 29 endocrine and special chemistry biomarkers on the Beckman Coulter Immunoassay Systems: a CALIPER study of healthy community children.

    PubMed

    Karbasy, Kimiya; Lin, Danny C C; Stoianov, Alexandra; Chan, Man Khun; Bevilacqua, Victoria; Chen, Yunqi; Adeli, Khosrow

    2016-04-01

    The CALIPER program is a national research initiative aimed at closing the gaps in pediatric reference intervals. CALIPER previously reported reference intervals for endocrine and special chemistry markers on Abbott immunoassays. We now report new pediatric reference intervals for immunoassays on the Beckman Coulter Immunoassay Systems and assess platform-specific differences in reference values. A total of 711 healthy children and adolescents from birth to <19 years of age were recruited from the community. Serum samples were collected for measurement of 29 biomarkers on the Beckman Coulter Immunoassay Systems. Statistically relevant age and/or gender-based partitions were determined, outliers removed, and reference intervals calculated in accordance with Clinical and Laboratory Standards Institute (CLSI) EP28-A3c guidelines. Complex profiles were observed for all 29 analytes, necessitating unique age and/or sex-specific partitions. Overall, changes in analyte concentrations observed over the course of development were similar to trends previously reported, and are consistent with biochemical and physiological changes that occur during childhood. Marked differences were observed for some assays including progesterone, luteinizing hormone and follicle-stimulating hormone where reference intervals were higher than those reported on Abbott immunoassays and parathyroid hormone where intervals were lower. This study highlights the importance of determining reference intervals specific for each analytical platform. The CALIPER Pediatric Reference Interval database will enable accurate diagnosis and laboratory assessment of children monitored by Beckman Coulter Immunoassay Systems in health care institutions worldwide. These reference intervals must however be validated by individual labs for the local pediatric population as recommended by CLSI.

  16. Hematology and biochemistry reference intervals for Ontario commercial nursing pigs close to the time of weaning

    PubMed Central

    Perri, Amanda M.; O’Sullivan, Terri L.; Harding, John C.S.; Wood, R. Darren; Friendship, Robert M.

    2017-01-01

    The evaluation of pig hematology and biochemistry parameters is rarely done largely due to the costs associated with laboratory testing and labor, and the limited availability of reference intervals needed for interpretation. Within-herd and between-herd biological variation of these values also make it difficult to establish reference intervals. Regardless, baseline reference intervals are important to aid veterinarians in the interpretation of blood parameters for the diagnosis and treatment of diseased swine. The objective of this research was to provide reference intervals for hematology and biochemistry parameters of 3-week-old commercial nursing piglets in Ontario. A total of 1032 pigs lacking clinical signs of disease from 20 swine farms were sampled for hematology and iron panel evaluation, with biochemistry analysis performed on a subset of 189 randomly selected pigs. The 95% reference interval, mean, median, range, and 90% confidence intervals were calculated for each parameter. PMID:28373729

  17. Indirect methods for reference interval determination - review and recommendations.

    PubMed

    Jones, Graham R D; Haeckel, Rainer; Loh, Tze Ping; Sikaris, Ken; Streichert, Thomas; Katayev, Alex; Barth, Julian H; Ozarda, Yesim

    2018-04-19

    Reference intervals are a vital part of the information supplied by clinical laboratories to support interpretation of numerical pathology results such as are produced in clinical chemistry and hematology laboratories. The traditional method for establishing reference intervals, known as the direct approach, is based on collecting samples from members of a preselected reference population, making the measurements and then determining the intervals. An alternative approach is to perform analysis of results generated as part of routine pathology testing and using appropriate statistical techniques to determine reference intervals. This is known as the indirect approach. This paper from a working group of the International Federation of Clinical Chemistry (IFCC) Committee on Reference Intervals and Decision Limits (C-RIDL) aims to summarize current thinking on indirect approaches to reference intervals. The indirect approach has some major potential advantages compared with direct methods. The processes are faster, cheaper and do not involve patient inconvenience, discomfort or the risks associated with generating new patient health information. Indirect methods also use the same preanalytical and analytical techniques used for patient management and can provide very large numbers for assessment. Limitations to the indirect methods include possible effects of diseased subpopulations on the derived interval. The IFCC C-RIDL aims to encourage the use of indirect methods to establish and verify reference intervals, to promote publication of such intervals with clear explanation of the process used and also to support the development of improved statistical techniques for these studies.

  18. Collaborative derivation of reference intervals for major clinical laboratory tests in Japan.

    PubMed

    Ichihara, Kiyoshi; Yomamoto, Yoshikazu; Hotta, Taeko; Hosogaya, Shigemi; Miyachi, Hayato; Itoh, Yoshihisa; Ishibashi, Midori; Kang, Dongchon

    2016-05-01

    Three multicentre studies of reference intervals were conducted recently in Japan. The Committee on Common Reference Intervals of the Japan Society of Clinical Chemistry sought to establish common reference intervals for 40 laboratory tests which were measured in common in the three studies and regarded as well harmonized in Japan. The study protocols were comparable with recruitment mostly from hospital workers with body mass index ≤28 and no medications. Age and sex distributions were made equal to obtain a final data size of 6345 individuals. Between-subgroup differences were expressed as the SD ratio (between-subgroup SD divided by SD representing the reference interval). Between-study differences were all within acceptable levels, and thus the three datasets were merged. By adopting SD ratio ≥0.50 as a guide, sex-specific reference intervals were necessary for 12 assays. Age-specific reference intervals for females partitioned at age 45 were required for five analytes. The reference intervals derived by the parametric method resulted in appreciable narrowing of the ranges by applying the latent abnormal values exclusion method in 10 items which were closely associated with prevalent disorders among healthy individuals. Sex- and age-related profiles of reference values, derived from individuals with no abnormal results in major tests, showed peculiar patterns specific to each analyte. Common reference intervals for nationwide use were developed for 40 major tests, based on three multicentre studies by advanced statistical methods. Sex- and age-related profiles of reference values are of great relevance not only for interpreting test results, but for applying clinical decision limits specified in various clinical guidelines. © The Author(s) 2015.

  19. CLSI-based transference of the CALIPER database of pediatric reference intervals from Abbott to Beckman, Ortho, Roche and Siemens Clinical Chemistry Assays: direct validation using reference samples from the CALIPER cohort.

    PubMed

    Estey, Mathew P; Cohen, Ashley H; Colantonio, David A; Chan, Man Khun; Marvasti, Tina Binesh; Randell, Edward; Delvin, Edgard; Cousineau, Jocelyne; Grey, Vijaylaxmi; Greenway, Donald; Meng, Qing H; Jung, Benjamin; Bhuiyan, Jalaluddin; Seccombe, David; Adeli, Khosrow

    2013-09-01

    The CALIPER program recently established a comprehensive database of age- and sex-stratified pediatric reference intervals for 40 biochemical markers. However, this database was only directly applicable for Abbott ARCHITECT assays. We therefore sought to expand the scope of this database to biochemical assays from other major manufacturers, allowing for a much wider application of the CALIPER database. Based on CLSI C28-A3 and EP9-A2 guidelines, CALIPER reference intervals were transferred (using specific statistical criteria) to assays performed on four other commonly used clinical chemistry platforms including Beckman Coulter DxC800, Ortho Vitros 5600, Roche Cobas 6000, and Siemens Vista 1500. The resulting reference intervals were subjected to a thorough validation using 100 reference specimens (healthy community children and adolescents) from the CALIPER bio-bank, and all testing centers participated in an external quality assessment (EQA) evaluation. In general, the transferred pediatric reference intervals were similar to those established in our previous study. However, assay-specific differences in reference limits were observed for many analytes, and in some instances were considerable. The results of the EQA evaluation generally mimicked the similarities and differences in reference limits among the five manufacturers' assays. In addition, the majority of transferred reference intervals were validated through the analysis of CALIPER reference samples. This study greatly extends the utility of the CALIPER reference interval database which is now directly applicable for assays performed on five major analytical platforms in clinical use, and should permit the worldwide application of CALIPER pediatric reference intervals. Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  20. Reference Intervals of Alpha-Fetoprotein and Carcinoembryonic Antigen in the Apparently Healthy Population.

    PubMed

    Zhang, Gao-Ming; Guo, Xu-Xiao; Ma, Xiao-Bo; Zhang, Guo-Ming

    2016-12-12

    BACKGROUND The aim of this study was to calculate 95% reference intervals and double-sided limits of serum alpha-fetoprotein (AFP) and carcinoembryonic antigen (CEA) according to the CLSI EP28-A3 guideline. MATERIAL AND METHODS Serum AFP and CEA values were measured in samples from 26 000 healthy subjects in the Shuyang area receiving general health checkups. The 95% reference intervals and upper limits were calculated by using MedCalc. RESULTS We provided continuous reference intervals from 20 years old to 90 years old for AFP and CEA. The reference intervals were: AFP, 1.31-7.89 ng/ml (males) and 1.01-7.10 ng/ml (females); CEA, 0.51-4.86 ng/ml (males) and 0.35-3.45ng/ml (females). AFP and CEA were significantly positively correlated with age in both males (r=0.196 and r=0.198) and females (r=0.121 and r=0.197). CONCLUSIONS Different races or populations and different detection systems may result in different reference intervals for AFP and CEA. Continuous reference intervals of age changes are more accurate than age groups.

  1. SENIORLAB: a prospective observational study investigating laboratory parameters and their reference intervals in the elderly.

    PubMed

    Risch, Martin; Nydegger, Urs; Risch, Lorenz

    2017-01-01

    In clinical practice, laboratory results are often important for making diagnostic, therapeutic, and prognostic decisions. Interpreting individual results relies on accurate reference intervals and decision limits. Despite the considerable amount of resources in clinical medicine spent on elderly patients, accurate reference intervals for the elderly are rarely available. The SENIORLAB study set out to determine reference intervals in the elderly by investigating a large variety of laboratory parameters in clinical chemistry, hematology, and immunology. The SENIORLAB study is an observational, prospective cohort study. Subjectively healthy residents of Switzerland aged 60 years and older were included for baseline examination (n = 1467), where anthropometric measurements were taken, medical history was reviewed, and a fasting blood sample was drawn under optimal preanalytical conditions. More than 110 laboratory parameters were measured, and a biobank was set up. The study participants are followed up every 3 to 5 years for quality of life, morbidity, and mortality. The primary aim is to evaluate different laboratory parameters at age-related reference intervals. The secondary aims of this study include the following: identify associations between different parameters, identify diagnostic characteristics to diagnose different circumstances, identify the prevalence of occult disease in subjectively healthy individuals, and identify the prognostic factors for the investigated outcomes, including mortality. To obtain better grounds to justify clinical decisions, specific reference intervals for laboratory parameters of the elderly are needed. Reference intervals are obtained from healthy individuals. A major obstacle when obtaining reference intervals in the elderly is the definition of health in seniors because individuals without any medical condition and any medication are rare in older adulthood. Reference intervals obtained from such individuals cannot be considered representative for seniors in a status of age-specific normal health. In addition to the established methods for determining reference intervals, this longitudinal study utilizes a unique approach, in that survival and long-term well-being are taken as indicators of health in seniors. This approach is expected to provide robust and representative reference intervals that are obtained from an adequate reference population and not a collective of highly selected individuals. The present study was registered under International Standard Randomized Controlled Trial Number registry: ISRCTN53778569.

  2. Evaluation of locally established reference intervals for hematology and biochemistry parameters in Western Kenya.

    PubMed

    Odhiambo, Collins; Oyaro, Boaz; Odipo, Richard; Otieno, Fredrick; Alemnji, George; Williamson, John; Zeh, Clement

    2015-01-01

    Important differences have been demonstrated in laboratory parameters from healthy persons in different geographical regions and populations, mostly driven by a combination of genetic, demographic, nutritional, and environmental factors. Despite this, European and North American derived laboratory reference intervals are used in African countries for patient management, clinical trial eligibility, and toxicity determination; which can result in misclassification of healthy persons as having laboratory abnormalities. An observational prospective cohort study known as the Kisumu Incidence Cohort Study (KICoS) was conducted to estimate the incidence of HIV seroconversion and identify determinants of successful recruitment and retention in preparation for an HIV vaccine/prevention trial among young adults and adolescents in western Kenya. Laboratory values generated from the KICoS were compared to published region-specific reference intervals and the 2004 NIH DAIDS toxicity tables used for the trial. About 1106 participants were screened for the KICoS between January 2007 and June 2010. Nine hundred and fifty-three participants aged 16 to 34 years, HIV-seronegative, clinically healthy, and non-pregnant were selected for this analysis. Median and 95% reference intervals were calculated for hematological and biochemistry parameters. When compared with both published region-specific reference values and the 2004 NIH DAIDS toxicity table, it was shown that the use of locally established reference intervals would have resulted in fewer participants classified as having abnormal hematological or biochemistry values compared to US derived reference intervals from DAIDS (10% classified as abnormal by local parameters vs. >40% by US DAIDS). Blood urea nitrogen was most often out of range if US based intervals were used: <10% abnormal by local intervals compared to >83% by US based reference intervals. Differences in reference intervals for hematological and biochemical parameters between western and African populations highlight importance of developing local reference intervals for clinical care and trials in Africa.

  3. Systematic review of serum steroid reference intervals developed using mass spectrometry.

    PubMed

    Tavita, Nevada; Greaves, Ronda F

    2017-12-01

    The aim of this study was to perform a systematic review of the published literature to determine the available serum/plasma steroid reference intervals generated by mass spectrometry (MS) methods across all age groups in healthy subjects and to suggest recommendations to achieve common MS based reference intervals for serum steroids. MEDLINE, EMBASE and PubMed databases were used to conduct a comprehensive search for English language, MS-based reference interval studies for serum/plasma steroids. Selection of steroids to include was based on those listed in the Royal College of Pathologists of Australasia Quality Assurance Programs, Chemical Pathology, Endocrine Program. This methodology has been registered onto the PROSPERO International prospective register of systematic reviews (ID number: CRD42015029637). After accounting for duplicates, a total of 60 manuscripts were identified through the search strategy. Following critical evaluation, a total of 16 studies were selected. Of the 16 studies, 12 reported reference intervals for testosterone, 11 for 17 hydroxy-progesterone, nine for androstenedione, six for cortisol, three for progesterone, two for dihydrotestosterone and only one for aldosterone and dehydroepiandrosterone sulphate. No studies established MS-based reference intervals for oestradiol. As far as we are aware, this report provides the first comparison of the peer reviewed literature for serum/plasma steroid reference intervals generated by MS-based methods. The reference intervals based on these published studies can be used to inform the process to develop common reference intervals, and agreed reporting units for mass spectrometry based steroid methods. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. Quality specifications for the extra-analytical phase of laboratory testing: Reference intervals and decision limits.

    PubMed

    Ceriotti, Ferruccio

    2017-07-01

    Reference intervals and decision limits are a critical part of the clinical laboratory report. The evaluation of their correct use represents a tool to verify the post analytical quality. Four elements are identified as indicators. 1. The use of decision limits for lipids and glycated hemoglobin. 2. The use, whenever possible, of common reference values. 3. The presence of gender-related reference intervals for at least the following common serum measurands (besides obviously the fertility relate hormones): alkaline phosphatase (ALP), alanine aminotransferase (ALT), creatine kinase (CK), creatinine, gamma-glutamyl transferase (GGT), IgM, ferritin, iron, transferrin, urate, red blood cells (RBC), hemoglobin (Hb) and hematocrit (Hct). 4. The presence of age-related reference intervals. The problem of specific reference intervals for elderly people is discussed, but their use is not recommended; on the contrary it is necessary the presence of pediatric age-related reference intervals at least for the following common serum measurands: ALP, amylase, creatinine, inorganic phosphate, lactate dehydrogenase, aspartate aminotransferase, urate, insulin like growth factor 1, white blood cells, RBC, Hb, Hct, alfa-fetoprotein and fertility related hormones. The lack of such reference intervals may imply significant risks for the patients. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  5. [Age- and sex-specific reference intervals for 10 health examination items: mega-data from a Japanese Health Service Association].

    PubMed

    Suka, Machi; Yoshida, Katsumi; Kawai, Tadashi; Aoki, Yoshikazu; Yamane, Noriyuki; Yamauchi, Kuniaki

    2005-07-01

    To determine age- and sex-specific reference intervals for 10 health examination items in Japanese adults. Health examination data were accumulated from 24 different prefectural health service associations affiliated with the Japan Association of Health Service. Those who were non-smokers, drank less than 7 days/week, and had a body mass index of 18.5-24.9kg/m2 were sampled as a reference population (n = 737,538; 224,947 men and 512,591 women). After classified by age and sex, reference intervals for 10 health examination items (systolic blood pressure, diastolic blood pressure, total cholesterol, triglyceride, glucose, uric acid, AST, ALT, gamma-GT, and hemoglobin) were estimated using the parametric and nonparametric methods. In every item except for hemoglobin, men had higher reference intervals than women. Systolic blood pressure, total cholesterol, and glucose showed an upward trend in values with increasing age. Hemoglobin showed a downward trend in values with increasing age. Triglyceride, ALT, and gamma-GT reached a peak in middle age. Overall, parametric estimates showed narrower reference intervals than non-parametric estimates. Reference intervals vary with age and sex. Age- and sex-specific reference intervals may contribute to better assessment of health examination data.

  6. Reference Intervals of Alpha-Fetoprotein and Carcinoembryonic Antigen in the Apparently Healthy Population

    PubMed Central

    Zhang, Gao-Ming; Guo, Xu-Xiao; Ma, Xiao-Bo; Zhang, Guo-Ming

    2016-01-01

    Background The aim of this study was to calculate 95% reference intervals and double-sided limits of serum alpha-fetoprotein (AFP) and carcinoembryonic antigen (CEA) according to the CLSI EP28-A3 guideline. Material/Methods Serum AFP and CEA values were measured in samples from 26 000 healthy subjects in the Shuyang area receiving general health checkups. The 95% reference intervals and upper limits were calculated by using MedCalc. Results We provided continuous reference intervals from 20 years old to 90 years old for AFP and CEA. The reference intervals were: AFP, 1.31–7.89 ng/ml (males) and 1.01–7.10 ng/ml (females); CEA, 0.51–4.86 ng/ml (males) and 0.35–3.45ng/ml (females). AFP and CEA were significantly positively correlated with age in both males (r=0.196 and r=0.198) and females (r=0.121 and r=0.197). Conclusions Different races or populations and different detection systems may result in different reference intervals for AFP and CEA. Continuous reference intervals of age changes are more accurate than age groups. PMID:27941709

  7. ESTABLISHMENT OF A FIBRINOGEN REFERENCE INTERVAL IN ORNATE BOX TURTLES (TERRAPENE ORNATA ORNATA).

    PubMed

    Parkinson, Lily; Olea-Popelka, Francisco; Klaphake, Eric; Dadone, Liza; Johnston, Matthew

    2016-09-01

    This study sought to establish a reference interval for fibrinogen in healthy ornate box turtles ( Terrapene ornata ornata). A total of 48 turtles were enrolled, with 42 turtles deemed to be noninflammatory and thus fitting the inclusion criteria and utilized to estimate a fibrinogen reference interval. Turtles were excluded based upon physical examination and blood work abnormalities. A Shapiro-Wilk normality test indicated that the noninflammatory turtle fibrinogen values were normally distributed (Gaussian distribution) with an average of 108 mg/dl and a 95% confidence interval of the mean of 97.9-117 mg/dl. Those turtles excluded from the reference interval because of abnormalities affecting their health had significantly different fibrinogen values (P = 0.313). A reference interval for healthy ornate box turtles was calculated. Further investigation into the utility of fibrinogen measurement for clinical usage in ornate box turtles is warranted.

  8. Valid analytical performance specifications for combined analytical bias and imprecision for the use of common reference intervals.

    PubMed

    Hyltoft Petersen, Per; Lund, Flemming; Fraser, Callum G; Sandberg, Sverre; Sölétormos, György

    2018-01-01

    Background Many clinical decisions are based on comparison of patient results with reference intervals. Therefore, an estimation of the analytical performance specifications for the quality that would be required to allow sharing common reference intervals is needed. The International Federation of Clinical Chemistry (IFCC) recommended a minimum of 120 reference individuals to establish reference intervals. This number implies a certain level of quality, which could then be used for defining analytical performance specifications as the maximum combination of analytical bias and imprecision required for sharing common reference intervals, the aim of this investigation. Methods Two methods were investigated for defining the maximum combination of analytical bias and imprecision that would give the same quality of common reference intervals as the IFCC recommendation. Method 1 is based on a formula for the combination of analytical bias and imprecision and Method 2 is based on the Microsoft Excel formula NORMINV including the fractional probability of reference individuals outside each limit and the Gaussian variables of mean and standard deviation. The combinations of normalized bias and imprecision are illustrated for both methods. The formulae are identical for Gaussian and log-Gaussian distributions. Results Method 2 gives the correct results with a constant percentage of 4.4% for all combinations of bias and imprecision. Conclusion The Microsoft Excel formula NORMINV is useful for the estimation of analytical performance specifications for both Gaussian and log-Gaussian distributions of reference intervals.

  9. Reference values of thirty-one frequently used laboratory markers for 75-year-old males and females

    PubMed Central

    Ryden, Ingvar; Lind, Lars

    2012-01-01

    Background We have previously reported reference values for common clinical chemistry tests in healthy 70-year-old males and females. We have now repeated this study 5 years later to establish reference values also at the age of 75. It is important to have adequate reference values for elderly patients as biological markers may change over time, and adequate reference values are essential for correct clinical decisions. Methods We have investigated 31 frequently used laboratory markers in 75-year-old males (n = 354) and females (n = 373) without diabetes. The 2.5 and 97.5 percentiles for these markers were calculated according to the recommendations of the International Federation of Clinical Chemistry. Results Reference values are reported for 75-year-old males and females for 31 frequently used laboratory markers. Conclusion There were minor differences between reference intervals calculated with and without individuals with cardiovascular diseases. Several of the reference intervals differed from Scandinavian reference intervals based on younger individuals (Nordic Reference Interval Project). PMID:22300333

  10. Clinical chemistry reference intervals of healthy adult populations in Gojjam Zones of Amhara National Regional State, Northwest Ethiopia.

    PubMed

    Mekonnen, Zewdie; Amuamuta, Asmare; Mulu, Wondemagegn; Yimer, Mulat; Zenebe, Yohannes; Adem, Yesuf; Abera, Bayeh; Gebeyehu, Wondemu; Gebregziabher, Yakob

    2017-01-01

    Reference interval is crucial for disease screening, diagnosis, monitoring, progression and treatment efficacy. Due to lack of locally derived reference values for the parameters, clinicians use reference intervals derived from western population. But, studies conducted in different African countries have indicated differences between locally and western derived reference values. Different studies also indicated considerable variation in clinical chemistry reference intervals by several variables such as age, sex, geographical location, environment, lifestyle and genetic variation. This study aimed to determine the reference intervals of common clinical chemistry parameters of the community of Gojjam Zones, Northwest Ethiopia. Population based cross-sectional study was conducted from November 2015 to December 2016 in healthy adult populations of Gojjam zone. Data such as, medical history, physical examination and socio-demographic data were collected. In addition, laboratory investigations were undertaken to screen the population. Clinical chemistry parameters were measured using Mindray BS 200 clinical chemistry autoanalyzer as per the manufacturer's instructions. Descriptive statistics was used to calculate mean, median and 95th percentiles. Independent sample T-test and one way ANOVA were used to see association between variables. After careful screening of a total of 799 apparently healthy adults who were consented for this study, complete data from 446 (224 females and 222 males) were included for the analysis. The mean age of both the study participants was 28.8 years. Males had high (P<0.05) mean and 2.5th-97.5th percentile ranges of ALT, AST, ALP, creatinine and direct bilirubin. The reference intervals of amylase, LDH, total protein and total bilirubin were not significantly different between the two sex groups (P>0.05). Mean, median, 95% percentile values of AST, ALP, amylase, LDH, creatinine, total protein, total bilirubin, and direct bilirubin across all age groups of participants were similar (P>0.05). But, there was a significant difference in the value of ALT (P<0.05). The reference intervals of ALT, total protein and creatinine were significantly (P<0.05) high in people having monthly income >1500 ETB compared to those with low monthly income. Significant (P<0.05) higher values of the ALT, ALP and total protein were observed in people living in high land compared to low land residences. The study showed that some of the common clinical chemistry parameters reference intervals of healthy adults in Gojjam zones were higher than the reference intervals generated from developed countries. Therefore, strict adherence to the reference values generated in developed countries could lead to inappropriate diagnosis and treatment of patients. There was also variation of reference interval values based on climate, gender, age, monthly income and geographical locations. Therefore, further study is required to establish reference intervals for Ethiopian population.

  11. Pediatric Reference Intervals for Free Thyroxine and Free Triiodothyronine

    PubMed Central

    Jang, Megan; Guo, Tiedong; Soldin, Steven J.

    2009-01-01

    Background The clinical value of free thyroxine (FT4) and free triiodothyronine (FT3) analysis depends on the reference intervals with which they are compared. We determined age- and sex-specific reference intervals for neonates, infants, and children 0–18 years of age for FT4 and FT3 using tandem mass spectrometry. Methods Reference intervals were calculated for serum FT4 (n = 1426) and FT3 (n = 1107) obtained from healthy children between January 1, 2008, and June 30, 2008, from Children's National Medical Center and Georgetown University Medical Center Bioanalytical Core Laboratory, Washington, DC. Serum samples were analyzed using isotope dilution liquid chromatography tandem mass spectrometry (LC/MS/MS) with deuterium-labeled internal standards. Results FT4 reference intervals were very similar for males and females of all ages and ranged between 1.3 and 2.4 ng/dL for children 1 to 18 years old. FT4 reference intervals for 1- to 12-month-old infants were 1.3–2.8 ng/dL. These 2.5 to 97.5 percentile intervals were much tighter than reference intervals obtained using immunoassay platforms 0.48–2.78 ng/dL for males and 0.85–2.09 ng/dL for females. Similarly, FT3 intervals were consistent and similar for males and females and for all ages, ranging between 1.5 pg/mL and approximately 6.0 pg/mL for children 1 month of age to 18 years old. Conclusions This is the first study to provide pediatric reference intervals of FT4 and FT3 for children from birth to 18 years of age using LC/MS/MS. Analysis using LC/MS/MS provides more specific quantification of thyroid hormones. A comparison of the ultrafiltration tandem mass spectrometric method with equilibrium dialysis showed very good correlation. PMID:19583487

  12. BRIDGING GAPS BETWEEN ZOO AND WILDLIFE MEDICINE: ESTABLISHING REFERENCE INTERVALS FOR FREE-RANGING AFRICAN LIONS (PANTHERA LEO).

    PubMed

    Broughton, Heather M; Govender, Danny; Shikwambana, Purvance; Chappell, Patrick; Jolles, Anna

    2017-06-01

    The International Species Information System has set forth an extensive database of reference intervals for zoologic species, allowing veterinarians and game park officials to distinguish normal health parameters from underlying disease processes in captive wildlife. However, several recent studies comparing reference values from captive and free-ranging animals have found significant variation between populations, necessitating the development of separate reference intervals in free-ranging wildlife to aid in the interpretation of health data. Thus, this study characterizes reference intervals for six biochemical analytes, eleven hematologic or immune parameters, and three hormones using samples from 219 free-ranging African lions ( Panthera leo ) captured in Kruger National Park, South Africa. Using the original sample population, exclusion criteria based on physical examination were applied to yield a final reference population of 52 clinically normal lions. Reference intervals were then generated via 90% confidence intervals on log-transformed data using parametric bootstrapping techniques. In addition to the generation of reference intervals, linear mixed-effect models and generalized linear mixed-effect models were used to model associations of each focal parameter with the following independent variables: age, sex, and body condition score. Age and sex were statistically significant drivers for changes in hepatic enzymes, renal values, hematologic parameters, and leptin, a hormone related to body fat stores. Body condition was positively correlated with changes in monocyte counts. Given the large variation in reference values taken from captive versus free-ranging lions, it is our hope that this study will serve as a baseline for future clinical evaluations and biomedical research targeting free-ranging African lions.

  13. Trace element reference values in tissues from inhabitants of the EU. XII. Development of BioReVa program for statistical treatment.

    PubMed

    Iversen, B S; Sabbioni, E; Fortaner, S; Pietra, R; Nicolotti, A

    2003-01-20

    Statistical data treatment is a key point in the assessment of trace element reference values being the conclusive stage of a comprehensive and organized evaluation process of metal concentration in human body fluids. The EURO TERVIHT project (Trace Elements Reference Values in Human Tissues) was started for evaluating, checking and suggesting harmonized procedures for the establishment of trace element reference intervals in body fluids and tissues. Unfortunately, different statistical approaches are being used in this research field making data comparison difficult and in some cases impossible. Although international organizations such as International Federation of Clinical Chemistry (IFCC) or International Union of Pure and Applied Chemistry (IUPAC) have issued recommended guidelines for reference values assessment, including the statistical data treatment, a unique format and a standardized data layout is still missing. The aim of the present study is to present a software (BioReVa) running under Microsoft Windows platform suitable for calculating the reference intervals of trace elements in body matrices. The main scope for creating an ease-of-use application was to control the data distribution, to establish the reference intervals according to the accepted recommendation, on the base of the simple statistic, to get a standard presentation of experimental data and to have an application to which further need could be integrated in future. BioReVa calculates the IFCC reference intervals as well as the coverage intervals recommended by IUPAC as a supplement to the IFCC intervals. Examples of reference values and reference intervals calculated with BioReVa software concern Pb and Se in blood; Cd, In and Cr in urine, Hg and Mo in hair of different general European populations. University of Michigan

  14. Reference interval for thyrotropin in a ultrasonography screened Korean population

    PubMed Central

    Kim, Mijin; Kim, Soo Han; Lee, Yunkyoung; Park, Su-yeon; Kim, Hyung-don; Kwon, Hyemi; Choi, Yun Mi; Jang, Eun Kyung; Jeon, Min Ji; Kim, Won Gu; Shong, Young Kee; Kim, Won Bae

    2015-01-01

    Background/Aims The diagnostic accuracy of thyroid dysfunctions is primarily affected by the validity of the reference interval for serum thyroid-stimulating hormone (TSH). Thus, the present study aimed to establish a reference interval for TSH using a normal Korean population. Methods This study included 19,465 subjects who were recruited after undergoing routine health check-ups. Subjects with overt thyroid disease, a prior history of thyroid disease, or a family history of thyroid cancer were excluded from the present analyses. The reference range for serum TSH was evaluated in a normal Korean reference population which was defined according to criteria based on the guidelines of the National Academy of Clinical Biochemistry, ultrasound (US) findings, and smoking status. Sex and age were also taken into consideration when evaluating the distribution of serum TSH levels in different groups. Results In the presence of positive anti-thyroid peroxidase antibodies or abnormal US findings, the central 95 percentile interval of the serum TSH levels was widened. Additionally, the distribution of serum TSH levels shifted toward lower values in the current smokers group. The reference interval for TSH obtained using a normal Korean reference population was 0.73 to 7.06 mIU/L. The serum TSH levels were higher in females than in males in all groups, and there were no age-dependent shifts. Conclusions The present findings demonstrate that the serum TSH reference interval in a normal Korean reference population was higher than that in other countries. This result suggests that the upper and lower limits of the TSH reference interval, which was previously defined by studies from Western countries, should be raised for Korean populations. PMID:25995664

  15. Reference intervals for selected serum biochemistry analytes in cheetahs Acinonyx jubatus.

    PubMed

    Hudson-Lamb, Gavin C; Schoeman, Johan P; Hooijberg, Emma H; Heinrich, Sonja K; Tordiffe, Adrian S W

    2016-02-26

    Published haematologic and serum biochemistry reference intervals are very scarce for captive cheetahs and even more for free-ranging cheetahs. The current study was performed to establish reference intervals for selected serum biochemistry analytes in cheetahs. Baseline serum biochemistry analytes were analysed from 66 healthy Namibian cheetahs. Samples were collected from 30 captive cheetahs at the AfriCat Foundation and 36 free-ranging cheetahs from central Namibia. The effects of captivity-status, age, sex and haemolysis score on the tested serum analytes were investigated. The biochemistry analytes that were measured were sodium, potassium, magnesium, chloride, urea and creatinine. The 90% confidence interval of the reference limits was obtained using the non-parametric bootstrap method. Reference intervals were preferentially determined by the non-parametric method and were as follows: sodium (128 mmol/L - 166 mmol/L), potassium (3.9 mmol/L - 5.2 mmol/L), magnesium (0.8 mmol/L - 1.2 mmol/L), chloride (97 mmol/L - 130 mmol/L), urea (8.2 mmol/L - 25.1 mmol/L) and creatinine (88 µmol/L - 288 µmol/L). Reference intervals from the current study were compared with International Species Information System values for cheetahs and found to be narrower. Moreover, age, sex and haemolysis score had no significant effect on the serum analytes in this study. Separate reference intervals for captive and free-ranging cheetahs were also determined. Captive cheetahs had higher urea values, most likely due to dietary factors. This study is the first to establish reference intervals for serum biochemistry analytes in cheetahs according to international guidelines. These results can be used for future health and disease assessments in both captive and free-ranging cheetahs.

  16. Harmonising Reference Intervals for Three Calculated Parameters used in Clinical Chemistry.

    PubMed

    Hughes, David; Koerbin, Gus; Potter, Julia M; Glasgow, Nicholas; West, Nic; Abhayaratna, Walter P; Cavanaugh, Juleen; Armbruster, David; Hickman, Peter E

    2016-08-01

    For more than a decade there has been a global effort to harmonise all phases of the testing process, with particular emphasis on the most frequently utilised measurands. In addition, it is recognised that calculated parameters derived from these measurands should also be a target for harmonisation. Using data from the Aussie Normals study we report reference intervals for three calculated parameters: serum osmolality, serum anion gap and albumin-adjusted serum calcium. The Aussie Normals study was an a priori study that analysed samples from 1856 healthy volunteers. The nine analytes used for the calculations in this study were measured on Abbott Architect analysers. The data demonstrated normal (Gaussian) distributions for the albumin-adjusted serum calcium, the anion gap (using potassium in the calculation) and the calculated serum osmolality (using both the Bhagat et al. and Smithline and Gardner formulae). To assess the suitability of these reference intervals for use as harmonised reference intervals, we reviewed data from the Royal College of Pathologists of Australasia/Australasian Association of Clinical Biochemists (RCPA/AACB) bias survey. We conclude that the reference intervals for the calculated serum osmolality (using the Smithline and Gardner formulae) may be suitable for use as a common reference interval. Although a common reference interval for albumin-adjusted serum calcium may be possible, further investigations (including a greater range of albumin concentrations) are needed. This is due to the bias between the Bromocresol Green (BCG) and Bromocresol Purple (BCP) methods at lower serum albumin concentrations. Problems with the measurement of Total CO 2 in the bias survey meant that we could not use the data for assessing the suitability of a common reference interval for the anion gap. Further study is required.

  17. Reference intervals for 24 laboratory parameters determined in 24-hour urine collections.

    PubMed

    Curcio, Raffaele; Stettler, Helen; Suter, Paolo M; Aksözen, Jasmin Barman; Saleh, Lanja; Spanaus, Katharina; Bochud, Murielle; Minder, Elisabeth; von Eckardstein, Arnold

    2016-01-01

    Reference intervals for many laboratory parameters determined in 24-h urine collections are either not publicly available or based on small numbers, not sex specific or not from a representative sample. Osmolality and concentrations or enzymatic activities of sodium, potassium, chloride, glucose, creatinine, citrate, cortisol, pancreatic α-amylase, total protein, albumin, transferrin, immunoglobulin G, α1-microglobulin, α2-macroglobulin, as well as porphyrins and their precursors (δ-aminolevulinic acid and porphobilinogen) were determined in 241 24-h urine samples of a population-based cohort of asymptomatic adults (121 men and 120 women). For 16 of these 24 parameters creatinine-normalized ratios were calculated based on 24-h urine creatinine. The reference intervals for these parameters were calculated according to the CLSI C28-A3 statistical guidelines. By contrast to most published reference intervals, which do not stratify for sex, reference intervals of 12 of 24 laboratory parameters in 24-h urine collections and of eight of 16 parameters as creatinine-normalized ratios differed significantly between men and women. For six parameters calculated as 24-h urine excretion and four parameters calculated as creatinine-normalized ratios no reference intervals had been published before. For some parameters we found significant and relevant deviations from previously reported reference intervals, most notably for 24-h urine cortisol in women. Ten 24-h urine parameters showed weak or moderate sex-specific correlations with age. By applying up-to-date analytical methods and clinical chemistry analyzers to 24-h urine collections from a large population-based cohort we provide as yet the most comprehensive set of sex-specific reference intervals calculated according to CLSI guidelines for parameters determined in 24-h urine collections.

  18. Reference intervals for serum reactive oxygen metabolites, biological antioxidant potential, and oxidative stress index in adult rams.

    PubMed

    Oikonomidis, Ioannis L; Kiosis, Evangelos A; Brozos, Christos N; Kritsepi-Konstantinou, Maria G

    2017-03-01

    OBJECTIVE To establish reference intervals for serum reactive oxygen metabolites (ROMs), biological antioxidant potential (BAP), and oxidative stress index (OSi) in adult rams by use of controlled preanalytic and analytic procedures. ANIMALS 123 healthy 1- to 4-year-old rams of 2 Greek breeds (Chios [n = 62] and Florina [61]). PROCEDURES 4 hours after rams were fed, a blood sample was obtained from each ram, and serum was harvested. Concentrations of ROMs and BAP were measured colorimetrically on a spectrophotometric analyzer. The OSi was calculated as ROMs concentration divided by BAP concentration. Combined and breed-specific reference intervals were calculated by use of nonparametric and robust methods, respectively. Reference intervals were defined as the 2.5th to 97.5th percentiles. RESULTS Reference intervals for ROMs, BAP, and OSi for all rams combined were 65 to 109 Carratelli units, 2,364 to 4,491 μmol/L, and 18.2 to 43.0 Carratelli units/(mmol/L), respectively. Reference intervals of Chios rams for ROMs, BAP, and OSi were 56 to 113 Carratelli units, 2,234 to 4,290 μmol/L, and 12.9 to 38.4 Carratelli units/(mmol/L), respectively. Reference intervals of Florina rams for ROMs, BAP, and OSi were 68 to 111 Carratelli units, 2,337 to 4,363 μmol/L, and 14.1 to 38.1 Carratelli units/(mmol/L), respectively. CONCLUSIONS AND CLINICAL RELEVANCE Reference intervals calculated in this study can be used as a guide for the interpretation of ROMs, BAP, and OSi results in rams and, under appropriate conditions, can be adopted for use by veterinary laboratories.

  19. Transference of CALIPER pediatric reference intervals to biochemical assays on the Roche cobas 6000 and the Roche Modular P.

    PubMed

    Higgins, Victoria; Chan, Man Khun; Nieuwesteeg, Michelle; Hoffman, Barry R; Bromberg, Irvin L; Gornall, Doug; Randell, Edward; Adeli, Khosrow

    2016-01-01

    The Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) has recently established pediatric age- and sex-specific reference intervals for over 85 biochemical markers on the Abbott Architect system. Previously, CALIPER reference intervals for several biochemical markers were successfully transferred from Abbott assays to Roche, Beckman, Ortho, and Siemens assays. This study further broadens the CALIPER database by performing transference and verification for 52 biochemical assays on the Roche cobas 6000 and the Roche Modular P. Using CLSI C28-A3 and EP9-A2 guidelines, transference of the CALIPER reference intervals was attempted for 16 assays on the Roche cobas 6000 and 36 on the Modular P. Calculated reference intervals were further verified using 100 healthy CALIPER samples. Most assays showed strong correlation between assay systems and were transferable from Abbott to the Roche cobas 6000 (81%) and the Modular P (86%). Bicarbonate and magnesium were not transferable on either system and calcium and prealbumin were not transferable to the Modular P. Of the transferable analytes, 62% and 61% were verified on the cobas 6000 and the Modular P, respectively. This study extends the utility of the CALIPER database to two additional analytical systems, which facilitates the broad application of CALIPER reference intervals at pediatric centers utilizing Roche biochemical assays. Transference studies across different analytical platforms can later be collectively analyzed in an attempt to develop common reference intervals across all clinical chemistry instruments to harmonize laboratory test interpretation in diagnosis and monitoring of pediatric disease. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  20. Bone turnover marker reference intervals in young females.

    PubMed

    Callegari, Emma T; Gorelik, Alexandra; Garland, Suzanne M; Chiang, Cherie Y; Wark, John D

    2017-07-01

    Background The use of bone turnover markers in clinical practice and research in younger people is limited by the lack of normative data and understanding of common causes of variation in bone turnover marker values in this demographic. To appropriately interpret bone turnover markers, robust reference intervals specific to age, development and sex are necessary. This study aimed to determine reference intervals of bone turnover markers in females aged 16-25 years participating in the Safe-D study. Methods Participants were recruited through social networking site Facebook and were asked to complete an extensive, online questionnaire and attend a site visit. Participants were tested for serum carboxy-terminal cross-linking telopeptide of type 1 collagen and total procollagen type 1 N-propeptide using the Roche Elecsys automated analyser. Reference intervals were determined using the 2.5th to 97.5th percentiles of normalized bone turnover marker values. Results Of 406 participants, 149 were excluded due to medical conditions or medication use (except hormonal contraception) which may affect bone metabolism. In the remaining 257 participants, the reference interval was 230-1000 ng/L for serum carboxy-terminal cross-linking telopeptide of type 1 collagen and 27-131  µg/L for procollagen type 1 N-propeptide. Both marker concentrations were inversely correlated with age and oral contraceptive pill use. Therefore, intervals specific to these variables were calculated. Conclusions We defined robust reference intervals for cross-linking telopeptide of type 1 collagen and procollagen type 1 N-propeptide in young females grouped by age and contraceptive pill use. We examined bone turnover markers' relationship with several lifestyle, clinical and demographic factors. Our normative intervals should aid interpretation of bone turnover markers in young females particularly in those aged 16 to 19 years where reference intervals are currently provisional.

  1. Hematologic and serum chemistry reference intervals for free-ranging lions (Panthera leo).

    PubMed

    Maas, Miriam; Keet, Dewald F; Nielen, Mirjam

    2013-08-01

    Hematologic and serum chemistry values are used by veterinarians and wildlife researchers to assess health status and to identify abnormally high or low levels of a particular blood parameter in a target species. For free-ranging lions (Panthera leo) information about these values is scarce. In this study 7 hematologic and 11 serum biochemistry values were evaluated from 485 lions from the Kruger National Park, South Africa. Significant differences between sexes and sub-adult (≤ 36 months) and adult (>36 months) lions were found for most of the blood parameters and separate reference intervals were made for those values. The obtained reference intervals include the means of the various blood parameter values measured in captive lions, except for alkaline phosphatase in the subadult group. These reference intervals can be utilized for free-ranging lions, and may likely also be used as reference intervals for captive lions. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Clinical chemistry reference intervals of healthy adult populations in Gojjam Zones of Amhara National Regional State, Northwest Ethiopia

    PubMed Central

    Amuamuta, Asmare; Mulu, Wondemagegn; Yimer, Mulat; Zenebe, Yohannes; Adem, Yesuf; Abera, Bayeh; Gebeyehu, Wondemu; Gebregziabher, Yakob

    2017-01-01

    Background Reference interval is crucial for disease screening, diagnosis, monitoring, progression and treatment efficacy. Due to lack of locally derived reference values for the parameters, clinicians use reference intervals derived from western population. But, studies conducted in different African countries have indicated differences between locally and western derived reference values. Different studies also indicated considerable variation in clinical chemistry reference intervals by several variables such as age, sex, geographical location, environment, lifestyle and genetic variation. Objective This study aimed to determine the reference intervals of common clinical chemistry parameters of the community of Gojjam Zones, Northwest Ethiopia. Method Population based cross-sectional study was conducted from November 2015 to December 2016 in healthy adult populations of Gojjam zone. Data such as, medical history, physical examination and socio-demographic data were collected. In addition, laboratory investigations were undertaken to screen the population. Clinical chemistry parameters were measured using Mindray BS 200 clinical chemistry autoanalyzer as per the manufacturer’s instructions. Descriptive statistics was used to calculate mean, median and 95th percentiles. Independent sample T-test and one way ANOVA were used to see association between variables. Results After careful screening of a total of 799 apparently healthy adults who were consented for this study, complete data from 446 (224 females and 222 males) were included for the analysis. The mean age of both the study participants was 28.8 years. Males had high (P<0.05) mean and 2.5th-97.5th percentile ranges of ALT, AST, ALP, creatinine and direct bilirubin. The reference intervals of amylase, LDH, total protein and total bilirubin were not significantly different between the two sex groups (P>0.05). Mean, median, 95% percentile values of AST, ALP, amylase, LDH, creatinine, total protein, total bilirubin, and direct bilirubin across all age groups of participants were similar (P>0.05). But, there was a significant difference in the value of ALT (P<0.05). The reference intervals of ALT, total protein and creatinine were significantly (P<0.05) high in people having monthly income >1500 ETB compared to those with low monthly income. Significant (P<0.05) higher values of the ALT, ALP and total protein were observed in people living in high land compared to low land residences. Conclusion The study showed that some of the common clinical chemistry parameters reference intervals of healthy adults in Gojjam zones were higher than the reference intervals generated from developed countries. Therefore, strict adherence to the reference values generated in developed countries could lead to inappropriate diagnosis and treatment of patients. There was also variation of reference interval values based on climate, gender, age, monthly income and geographical locations. Therefore, further study is required to establish reference intervals for Ethiopian population. PMID:28886191

  3. Population-Based Pediatric Reference Intervals in General Clinical Chemistry: A Swedish Survey.

    PubMed

    Ridefelt, Peter

    2015-01-01

    Very few high quality studies on pediatric reference intervals for general clinical chemistry and hematology analytes have been performed. Three recent prospective community-based projects utilising blood samples from healthy children in Sweden, Denmark and Canada have substantially improved the situation. The Swedish survey included 701 healthy children. Reference intervals for general clinical chemistry and hematology were defined.

  4. 'Aussie normals': an a priori study to develop clinical chemistry reference intervals in a healthy Australian population.

    PubMed

    Koerbin, G; Cavanaugh, J A; Potter, J M; Abhayaratna, W P; West, N P; Glasgow, N; Hawkins, C; Armbruster, D; Oakman, C; Hickman, P E

    2015-02-01

    Development of reference intervals is difficult, time consuming, expensive and beyond the scope of most laboratories. The Aussie Normals study is a direct a priori study to determine reference intervals in healthy Australian adults. All volunteers completed a health and lifestyle questionnaire and exclusion was based on conditions such as pregnancy, diabetes, renal or cardiovascular disease. Up to 91 biochemical analyses were undertaken on a variety of analytical platforms using serum samples collected from 1856 volunteers. We report on our findings for 40 of these analytes and two calculated parameters performed on the Abbott ARCHITECTci8200/ci16200 analysers. Not all samples were analysed for all assays due to volume requirements or assay/instrument availability. Results with elevated interference indices and those deemed unsuitable after clinical evaluation were removed from the database. Reference intervals were partitioned based on the method of Harris and Boyd into three scenarios, combined gender, males and females and age and gender. We have performed a detailed reference interval study on a healthy Australian population considering the effects of sex, age and body mass. These reference intervals may be adapted to other manufacturer's analytical methods using method transference.

  5. Pediatric-specific reference intervals in a nationally representative sample of Iranian children and adolescents: the CASPIAN-III study.

    PubMed

    Kelishadi, Roya; Marateb, Hamid Reza; Mansourian, Marjan; Ardalan, Gelayol; Heshmat, Ramin; Adeli, Khosrow

    2016-08-01

    This study aimed to determine for the first time the age- and gender-specific reference intervals for biomarkers of bone, metabolism, nutrition, and obesity in a nationally representative sample of the Iranian children and adolescents. We assessed the data of blood samples obtained from healthy Iranian children and adolescents, aged 7 to 19 years. The reference intervals of glucose, lipid profile, liver enzymes, zinc, copper, chromium, magnesium, and 25-hydroxy vitamin D [25(OH)D] were determined according to the Clinical & Laboratory Standards Institute C28-A3 guidelines. The reference intervals were partitioned using the Harris-Boyd method according to age and gender. The study population consisted of 4800 school students (50% boys, mean age of 13.8 years). Twelve chemistry analyses were partitioned by age and gender, displaying the range of results between the 2.5th to 97.5th percentiles. Significant differences existed only between boys and girls at 18 to 19 years of age for low density lipoprotein-cholesterol. 25(OH)D had the only reference interval that was similar to all age groups and both sexes. This study presented the first national database of reference intervals for a number of biochemical markers in Iranian children and adolescents. It is the first report of its kind from the Middle East and North Africa. The findings underscore the importance of providing reference intervals in different ethnicities and in various regions.

  6. Reference interval estimation: Methodological comparison using extensive simulations and empirical data.

    PubMed

    Daly, Caitlin H; Higgins, Victoria; Adeli, Khosrow; Grey, Vijay L; Hamid, Jemila S

    2017-12-01

    To statistically compare and evaluate commonly used methods of estimating reference intervals and to determine which method is best based on characteristics of the distribution of various data sets. Three approaches for estimating reference intervals, i.e. parametric, non-parametric, and robust, were compared with simulated Gaussian and non-Gaussian data. The hierarchy of the performances of each method was examined based on bias and measures of precision. The findings of the simulation study were illustrated through real data sets. In all Gaussian scenarios, the parametric approach provided the least biased and most precise estimates. In non-Gaussian scenarios, no single method provided the least biased and most precise estimates for both limits of a reference interval across all sample sizes, although the non-parametric approach performed the best for most scenarios. The hierarchy of the performances of the three methods was only impacted by sample size and skewness. Differences between reference interval estimates established by the three methods were inflated by variability. Whenever possible, laboratories should attempt to transform data to a Gaussian distribution and use the parametric approach to obtain the most optimal reference intervals. When this is not possible, laboratories should consider sample size and skewness as factors in their choice of reference interval estimation method. The consequences of false positives or false negatives may also serve as factors in this decision. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  7. Circulating intact and cleaved forms of the urokinase-type plasminogen activator receptor: biological variation, reference intervals and clinical useful cut-points.

    PubMed

    Thurison, Tine; Christensen, Ib J; Lund, Ida K; Nielsen, Hans J; Høyer-Hansen, Gunilla

    2015-01-15

    High levels of circulating forms of the urokinase-type plasminogen activator receptor (uPAR) are significantly associated to poor prognosis in cancer patients. Our aim was to determine biological variations and reference intervals of the uPAR forms in blood, and in addition, to test the clinical relevance of using these as cut-points in colorectal cancer (CRC) prognosis. uPAR forms were measured in citrated and EDTA plasma samples using time-resolved fluorescence immunoassays. Diurnal, intra- and inter-individual variations were assessed in plasma samples from cohorts of healthy individuals. Reference intervals were determined in plasma from healthy individuals randomly selected from a Danish multi-center cross-sectional study. A cohort of CRC patients was selected from the same cross-sectional study. The reference intervals showed a slight increase with age and women had ~20% higher levels. The intra- and inter-individual variations were ~10% and ~20-30%, respectively and the measured levels of the uPAR forms were within the determined 95% reference intervals. No diurnal variation was found. Applying the normal upper limit of the reference intervals as cut-point for dichotomizing CRC patients revealed significantly decreased overall survival of patients with levels above this cut-point of any uPAR form. The reference intervals for the different uPAR forms are valid and the upper normal limits are clinically relevant cut-points for CRC prognosis. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Specific Immunoglobulin (Ig) G Reference Intervals for Common Food, Insect, and Mold Allergens.

    PubMed

    Martins, Thomas B; Bandhauer, Michael E; Wilcock, Diane M; Hill, Harry R; Slev, Patricia R

    2016-12-01

    The clinical utility of serum IgG measurement in the diagnosis of allergy and food-induced hypersensitivity has been largely discredited. Recent studies, however, have shown that specific IgG can inhibit IgE mediated allergies, and may play a role in allergen specific desensitization. Accurate reference intervals for IgG specific allergens have not been widely established and are needed for better interpretation of serum antibody concentrations. In this study we established 64 IgG reference intervals for 48 common food allergens, 5 venoms, and 11 molds. Specific IgG concentrations were determined employing an automated fluorescent enzyme immunoassay on serum samples from 130 normal adults (65 males and 65 females), age range 18-69 y, mean 37.3 y. The lower reference interval limit for all allergens tested (n=64) was <2 mcg/mL. The median upper reference interval value for all 64 allergens was 12.9 mcg/mL, with Tuna (f40) having the lowest upper interval limit at 3.8 mcg/mL, and the mold Setomelanomma rostrate (m8) demonstrating the highest upper interval limit at 131 mcg/L. The considerable variation observed among the upper reference interval limits emphasizes the need for the establishment of allergen specific ranges for IgG. These newly established ranges should be a useful aid for clinicians in the interpretation of laboratory serum IgG results. © 2016 by the Association of Clinical Scientists, Inc.

  9. Coordinates and intervals in graph-based reference genomes.

    PubMed

    Rand, Knut D; Grytten, Ivar; Nederbragt, Alexander J; Storvik, Geir O; Glad, Ingrid K; Sandve, Geir K

    2017-05-18

    It has been proposed that future reference genomes should be graph structures in order to better represent the sequence diversity present in a species. However, there is currently no standard method to represent genomic intervals, such as the positions of genes or transcription factor binding sites, on graph-based reference genomes. We formalize offset-based coordinate systems on graph-based reference genomes and introduce methods for representing intervals on these reference structures. We show the advantage of our methods by representing genes on a graph-based representation of the newest assembly of the human genome (GRCh38) and its alternative loci for regions that are highly variable. More complex reference genomes, containing alternative loci, require methods to represent genomic data on these structures. Our proposed notation for genomic intervals makes it possible to fully utilize the alternative loci of the GRCh38 assembly and potential future graph-based reference genomes. We have made a Python package for representing such intervals on offset-based coordinate systems, available at https://github.com/uio-cels/offsetbasedgraph . An interactive web-tool using this Python package to visualize genes on a graph created from GRCh38 is available at https://github.com/uio-cels/genomicgraphcoords .

  10. Standardization in laboratory medicine: Adoption of common reference intervals to the Croatian population.

    PubMed

    Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea

    2016-03-26

    Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients' care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine.

  11. [Establishing biological reference intervals of alanine transaminase for clinical laboratory stored database].

    PubMed

    Guo, Wei; Song, Binbin; Shen, Junfei; Wu, Jiong; Zhang, Chunyan; Wang, Beili; Pan, Baishen

    2015-08-25

    To establish an indirect reference interval based on the test results of alanine aminotransferase stored in a laboratory information system. All alanine aminotransferase results were included for outpatients and physical examinations that were stored in the laboratory information system of Zhongshan Hospital during 2014. The original data were transformed using a Box-Cox transformation to obtain an approximate normal distribution. Outliers were identified and omitted using the Chauvenet and Tukey methods. The indirect reference intervals were obtained by simultaneously applying nonparametric and Hoffmann methods. The reference change value was selected to determine the statistical significance of the observed differences between the calculated and published reference intervals. The indirect reference intervals for alanine aminotransferase of all groups were 12 to 41 U/L (male, outpatient), 12 to 48 U/L (male, physical examination), 9 to 32 U/L (female, outpatient), and 8 to 35 U/L (female, physical examination), respectively. The absolute differences when compared with the direct results were all smaller than the reference change value of alanine aminotransferase. The Box-Cox transformation combined with the Hoffmann and Tukey methods is a simple and reliable technique that should be promoted and used by clinical laboratories.

  12. Standardization in laboratory medicine: Adoption of common reference intervals to the Croatian population

    PubMed Central

    Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea

    2016-01-01

    Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients’ care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine. PMID:27019800

  13. Reference Intervals of Hematology and Clinical Chemistry Analytes for 1-Year-Old Korean Children

    PubMed Central

    Lee, Hye Ryun; Roh, Eun Youn; Chang, Ju Young

    2016-01-01

    Background Reference intervals need to be established according to age. We established reference intervals of hematology and chemistry from community-based healthy 1-yr-old children and analyzed their iron status according to the feeding methods during the first six months after birth. Methods A total of 887 children who received a medical check-up between 2010 and 2014 at Boramae Hospital (Seoul, Korea) were enrolled. A total of 534 children (247 boys and 287 girls) were enrolled as reference individuals after the exclusion of data obtained from children with suspected iron deficiency. Hematology and clinical chemistry analytes were measured, and the reference value of each analyte was estimated by using parametric (mean±2 SD) or nonparametric methods (2.5-97.5th percentile). Iron, total iron-binding capacity, and ferritin were measured, and transferrin saturation was calculated. Results As there were no differences in the mean values between boys and girls, we established the reference intervals for 1-yr-old children regardless of sex. The analysis of serum iron status according to feeding methods during the first six months revealed higher iron, ferritin, and transferrin saturation levels in children exclusively or mainly fed formula than in children exclusively or mainly fed breast milk. Conclusions We established reference intervals of hematology and clinical chemistry analytes from community-based healthy children at one year of age. These reference intervals will be useful for interpreting results of medical check-ups at one year of age. PMID:27374715

  14. Reference Intervals of Hematology and Clinical Chemistry Analytes for 1-Year-Old Korean Children.

    PubMed

    Lee, Hye Ryun; Shin, Sue; Yoon, Jong Hyun; Roh, Eun Youn; Chang, Ju Young

    2016-09-01

    Reference intervals need to be established according to age. We established reference intervals of hematology and chemistry from community-based healthy 1-yr-old children and analyzed their iron status according to the feeding methods during the first six months after birth. A total of 887 children who received a medical check-up between 2010 and 2014 at Boramae Hospital (Seoul, Korea) were enrolled. A total of 534 children (247 boys and 287 girls) were enrolled as reference individuals after the exclusion of data obtained from children with suspected iron deficiency. Hematology and clinical chemistry analytes were measured, and the reference value of each analyte was estimated by using parametric (mean±2 SD) or nonparametric methods (2.5-97.5th percentile). Iron, total iron-binding capacity, and ferritin were measured, and transferrin saturation was calculated. As there were no differences in the mean values between boys and girls, we established the reference intervals for 1-yr-old children regardless of sex. The analysis of serum iron status according to feeding methods during the first six months revealed higher iron, ferritin, and transferrin saturation levels in children exclusively or mainly fed formula than in children exclusively or mainly fed breast milk. We established reference intervals of hematology and clinical chemistry analytes from community-based healthy children at one year of age. These reference intervals will be useful for interpreting results of medical check-ups at one year of age.

  15. An automated and objective method for age partitioning of reference intervals based on continuous centile curves.

    PubMed

    Yang, Qian; Lew, Hwee Yeong; Peh, Raymond Hock Huat; Metz, Michael Patrick; Loh, Tze Ping

    2016-10-01

    Reference intervals are the most commonly used decision support tool when interpreting quantitative laboratory results. They may require partitioning to better describe subpopulations that display significantly different reference values. Partitioning by age is particularly important for the paediatric population since there are marked physiological changes associated with growth and maturation. However, most partitioning methods are either technically complex or require prior knowledge of the underlying physiology/biological variation of the population. There is growing interest in the use of continuous centile curves, which provides seamless laboratory reference values as a child grows, as an alternative to rigidly described fixed reference intervals. However, the mathematical functions that describe these curves can be complex and may not be easily implemented in laboratory information systems. Hence, the use of fixed reference intervals is expected to continue for a foreseeable time. We developed a method that objectively proposes optimised age partitions and reference intervals for quantitative laboratory data (http://research.sph.nus.edu.sg/pp/ppResult.aspx), based on the sum of gradient that best describes the underlying distribution of the continuous centile curves. It is hoped that this method may improve the selection of age intervals for partitioning, which is receiving increasing attention in paediatric laboratory medicine. Copyright © 2016 Royal College of Pathologists of Australasia. Published by Elsevier B.V. All rights reserved.

  16. Estimating reliable paediatric reference intervals in clinical chemistry and haematology.

    PubMed

    Ridefelt, Peter; Hellberg, Dan; Aldrimer, Mattias; Gustafsson, Jan

    2014-01-01

    Very few high-quality studies on paediatric reference intervals for general clinical chemistry and haematology analytes have been performed. Three recent prospective community-based projects utilising blood samples from healthy children in Sweden, Denmark and Canada have substantially improved the situation. The present review summarises current reference interval studies for common clinical chemistry and haematology analyses. ©2013 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  17. Electrocardiogram reference intervals for clinically normal wild-born chimpanzees (Pan troglodytes).

    PubMed

    Atencia, Rebeca; Revuelta, Luis; Somauroo, John D; Shave, Robert E

    2015-08-01

    To generate reference intervals for ECG variables in clinically normal chimpanzees (Pan troglodytes). 100 clinically normal (51 young [< 10 years old] and 49 adult [≥ 10 years old]) wild-born chimpanzees. Electrocardiograms collected between 2009 and 2013 at the Tchimpounga Chimpanzee Rehabilitation Centre were assessed to determine heart rate, PR interval, QRS duration, QT interval, QRS axis, P axis, and T axis. Electrocardiographic characteristics for left ventricular hypertrophy (LVH) and morphology of the ST segment, T wave, and QRS complex were identified. Reference intervals for young and old animals were calculated as mean ± 1.96•SD for normally distributed data and as 5th to 95th percentiles for data not normally distributed. Differences between age groups were assessed by use of unpaired Student t tests. RESULTS Reference intervals were generated for young and adult wild-born chimpanzees. Most animals had sinus rhythm with small or normal P wave morphology; 24 of 51 (47%) young chimpanzees and 30 of 49 (61%) adult chimpanzees had evidence of LVH as determined on the basis of criteria for humans. Cardiac disease has been implicated as the major cause of death in captive chimpanzees. Species-specific ECG reference intervals for chimpanzees may aid in the diagnosis and treatment of animals with, or at risk of developing, heart disease. Chimpanzees with ECG characteristics outside of these intervals should be considered for follow-up assessment and regular cardiac monitoring.

  18. Nonparametric spirometry reference values for Hispanic Americans.

    PubMed

    Glenn, Nancy L; Brown, Vanessa M

    2011-02-01

    Recent literature sites ethnic origin as a major factor in developing pulmonary function reference values. Extensive studies established reference values for European and African Americans, but not for Hispanic Americans. The Third National Health and Nutrition Examination Survey defines Hispanic as individuals of Spanish speaking cultures. While no group was excluded from the target population, sample size requirements only allowed inclusion of individuals who identified themselves as Mexican Americans. This research constructs nonparametric reference value confidence intervals for Hispanic American pulmonary function. The method is applicable to all ethnicities. We use empirical likelihood confidence intervals to establish normal ranges for reference values. Its major advantage: it is model free, but shares asymptotic properties of model based methods. Statistical comparisons indicate that empirical likelihood interval lengths are comparable to normal theory intervals. Power and efficiency studies agree with previously published theoretical results.

  19. Reference values for 34 frequently used laboratory tests in 80-year-old men and women.

    PubMed

    Helmersson-Karlqvist, Johanna; Ridefelt, Peter; Lind, Lars; Larsson, Anders

    2016-10-01

    Reference values are usually based on blood samples from healthy individuals in the age range 20-50 years. Most patients seeking health care are older than this reference population. Many reference intervals are age dependent and there is thus a need to have appropriate reference intervals also for elderly individuals. We analyzed a group of frequently used laboratory tests in an 80-year-old population (n=531, 266 females and 265 males). The 2.5th and 97.5th percentiles for these markers were calculated according to the International Federation of Clinical Chemistry guidelines on the statistical treatment of reference values. Reference values are reported for serum alanine transaminase (ALT), albumin, alkaline phosphatase, pancreatic amylase, apolipoprotein A1, apolipoprotein B, apolipoprotein B/apolipoprotein A1 ratio, aspartate aminotransferase (AST), AST/ALT ratio, bilirubin, calcium, calprotectin, cholesterol, HDL-cholesterol, creatinine kinase (CK), creatinine, creatinine estimated GFR, C-reactive protein, cystatin C, cystatin C estimated GFR, gamma-glutamyltransferase (GGT), iron, iron saturation, lactate dehydrogenase (LDH), magnesium, phosphate, transferrin, triglycerides, urate, urea, zinc, hemoglobin, platelet count and white blood cell count. The upper reference limit for creatinine and urea was significantly increased while the lower limit for iron and albumin was decreased in this elderly population in comparison with the population in the Nordic Reference Interval Project (NORIP). Reference values calculated from the whole population and a subpopulation without cardiovascular disease showed strong concordance. Several of the reference interval limits were outside the 90% confidence interval of NORIP. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Haematological and biochemical reference intervals for free-ranging brown bears (Ursus arctos) in Sweden

    PubMed Central

    2014-01-01

    Background Establishment of haematological and biochemical reference intervals is important to assess health of animals on individual and population level. Reference intervals for 13 haematological and 34 biochemical variables were established based on 88 apparently healthy free-ranging brown bears (39 males and 49 females) in Sweden. The animals were chemically immobilised by darting from a helicopter with a combination of medetomidine, tiletamine and zolazepam in April and May 2006–2012 in the county of Dalarna, Sweden. Venous blood samples were collected during anaesthesia for radio collaring and marking for ecological studies. For each of the variables, the reference interval was described based on the 95% confidence interval, and differences due to host characteristics sex and age were included if detected. To our knowledge, this is the first report of reference intervals for free-ranging brown bears in Sweden. Results The following variables were not affected by host characteristics: red blood cell, white blood cell, monocyte and platelet count, alanine transaminase, amylase, bilirubin, free fatty acids, glucose, calcium, chloride, potassium, and cortisol. Age differences were seen for the majority of the haematological variables, whereas sex influenced only mean corpuscular haemoglobin concentration, aspartate aminotransferase, lipase, lactate dehydrogenase, β-globulin, bile acids, triglycerides and sodium. Conclusions The biochemical and haematological reference intervals provided and the differences due to host factors age and gender can be useful for evaluation of health status in free-ranging European brown bears. PMID:25139149

  1. The reference intervals of thyroid stimulating hormone in healthy individuals with normal levels of serum free thyroxine and without sonographic pathologies.

    PubMed

    Kutluturk, Faruk; Yildirim, Beytullah; Ozturk, Banu; Ozyurt, Huseyin; Bekar, Ulku; Sahin, Semsettin; Akturk, Yeliz; Akbas, Ali; Cetin, Ilhan; Etikan, Ilker

    2014-01-01

    The aim of the present study was to investigate the reference intervals for thyroid stimulating hormone (TSH) in healthy individuals with normal levels of serum free thyroxine (fT4) and without sonographic pathologies, and determine the effects of age, gender, and residence on the TSH reference intervals. This research was a population-based study conducted in 70 regions. The random sampling method was used to select the 1095 subjects of the study among inhabitants aged 18 and above. Patients who had a previous history of thyroid disease and had been taking medication were excluded from the study as this may have affected their fT4 or TSH levels. In addition, subjects who had serum fT4 without a reference range and abnormal ultrasonography findings were also excluded. A total of 408 subjects were used for establishing the reference intervals for TSH. The data for TSH in the study group were not normally distributed according to the Kolmogorov-Smirnov index. The geometric mean was 1.62 mIU/L, the median was 1.40 mIU/L, and the 95% reference intervals were 0.38-4.22 mIU/L. The median TSH level was higher in females compared to males (p < 0.05). In the female subjects 2.5th percentile of TSH was lower and 97.5th percentile was higher than those of males. The reference intervals of TSH were of lower values in subjects over 50 years old (p < 0.001). Studies suggest that determination of the TSH reference intervals may differ due to environmental influences or due to age, gender, and race. It is suggested that the lower limit of normal TSH for the adult Turkish population would be 0.38 mIU/L and the upper limit similar to the traditional value of 4.2 mIU/L. If each clinician uses their population-specific reference interval for TSH, thyroid function abnormalities can be accurately estimated.

  2. Estimating clinical chemistry reference values based on an existing data set of unselected animals.

    PubMed

    Dimauro, Corrado; Bonelli, Piero; Nicolussi, Paola; Rassu, Salvatore P G; Cappio-Borlino, Aldo; Pulina, Giuseppe

    2008-11-01

    In an attempt to standardise the determination of biological reference values, the International Federation of Clinical Chemistry (IFCC) has published a series of recommendations on developing reference intervals. The IFCC recommends the use of an a priori sampling of at least 120 healthy individuals. However, such a high number of samples and laboratory analysis is expensive, time-consuming and not always feasible, especially in veterinary medicine. In this paper, an alternative (a posteriori) method is described and is used to determine reference intervals for biochemical parameters of farm animals using an existing laboratory data set. The method used was based on the detection and removal of outliers to obtain a large sample of animals likely to be healthy from the existing data set. This allowed the estimation of reliable reference intervals for biochemical parameters in Sarda dairy sheep. This method may also be useful for the determination of reference intervals for different species, ages and gender.

  3. Estimation of reference intervals from small samples: an example using canine plasma creatinine.

    PubMed

    Geffré, A; Braun, J P; Trumel, C; Concordet, D

    2009-12-01

    According to international recommendations, reference intervals should be determined from at least 120 reference individuals, which often are impossible to achieve in veterinary clinical pathology, especially for wild animals. When only a small number of reference subjects is available, the possible bias cannot be known and the normality of the distribution cannot be evaluated. A comparison of reference intervals estimated by different methods could be helpful. The purpose of this study was to compare reference limits determined from a large set of canine plasma creatinine reference values, and large subsets of this data, with estimates obtained from small samples selected randomly. Twenty sets each of 120 and 27 samples were randomly selected from a set of 1439 plasma creatinine results obtained from healthy dogs in another study. Reference intervals for the whole sample and for the large samples were determined by a nonparametric method. The estimated reference limits for the small samples were minimum and maximum, mean +/- 2 SD of native and Box-Cox-transformed values, 2.5th and 97.5th percentiles by a robust method on native and Box-Cox-transformed values, and estimates from diagrams of cumulative distribution functions. The whole sample had a heavily skewed distribution, which approached Gaussian after Box-Cox transformation. The reference limits estimated from small samples were highly variable. The closest estimates to the 1439-result reference interval for 27-result subsamples were obtained by both parametric and robust methods after Box-Cox transformation but were grossly erroneous in some cases. For small samples, it is recommended that all values be reported graphically in a dot plot or histogram and that estimates of the reference limits be compared using different methods.

  4. Pediatric reference intervals for general clinical chemistry components - merging of studies from Denmark and Sweden.

    PubMed

    Ridefelt, Peter; Hilsted, Linda; Juul, Anders; Hellberg, Dan; Rustad, Pål

    2018-05-28

    Reference intervals are crucial tools aiding clinicians when making medical decisions. However, for children such values often are lacking or incomplete. The present study combines data from separate pediatric reference interval studies of Denmark and Sweden in order to increase sample size and to include also pre-school children who were lacking in the Danish study. Results from two separate studies including 1988 healthy children and adolescents aged 6 months to 18 years of age were merged and recalculated. Eighteen general clinical chemistry components were measured on Abbott and Roche platforms. To facilitate commutability, the NFKK Reference Serum X was used. Age- and gender-specific pediatric reference intervals were defined by calculating 2.5 and 97.5 percentiles. The data generated are primarily applicable to a Nordic population, but could be used by any laboratory if validated for the local patient population.

  5. The impact of change in albumin assay on reference intervals, prevalence of 'hypoalbuminaemia' and albumin prescriptions.

    PubMed

    Coley-Grant, Deon; Herbert, Mike; Cornes, Michael P; Barlow, Ian M; Ford, Clare; Gama, Rousseau

    2016-01-01

    We studied the impact on reference intervals, classification of patients with hypoalbuminaemia and albumin infusion prescriptions on changing from a bromocresol green (BCG) to a bromocresol purple (BCP) serum albumin assay. Passing-Bablok regression analysis and Bland-Altman plot were used to compare Abbott BCP and Roche BCG methods. Linear regression analysis was used to compare in-house and an external laboratory Abbott BCP serum albumin results. Reference intervals for Abbott BCP serum albumin were derived in two different laboratories using pathology data from adult patients in primary care. Prescriptions for 20% albumin infusions were compared one year before and one year after changing the albumin method. Abbott BCP assay had a negative bias of approximately 6 g/L compared with Roche BCG method.There was good agreement (y = 1.04 x - 1.03; R(2 )= 0.9933) between in-house and external laboratory Abbott BCP results. Reference intervals for the serum albumin Abbott BCP assay were 31-45 g/L, different to those recommended by Pathology Harmony and the manufacturers (35-50 g/L). Following the change in method there was a large increase in the number of patients classified as hypoalbuminaemic using Pathology Harmony references intervals (32%) but not when retrospectively compared to locally derived reference intervals (16%) compared with the previous year (12%). The method change was associated with a 44.6% increase in albumin prescriptions. This equated to an annual increase in expenditure of £35,234. We suggest that serum albumin reference intervals be method specific to prevent misclassification of albumin status in patients. Change in albumin methodology may have significant impact on hospital resources. © The Author(s) 2015.

  6. Reference intervals for plasma free metanephrines with an age adjustment for normetanephrine for optimized laboratory testing of phaeochromocytoma.

    PubMed

    Eisenhofer, Graeme; Lattke, Peter; Herberg, Maria; Siegert, Gabriele; Qin, Nan; Därr, Roland; Hoyer, Jana; Villringer, Arno; Prejbisz, Aleksander; Januszewicz, Andrzej; Remaley, Alan; Martucci, Victoria; Pacak, Karel; Ross, H Alec; Sweep, Fred C G J; Lenders, Jacques W M

    2013-01-01

    Measurements of plasma normetanephrine and metanephrine provide a useful diagnostic test for phaeochromocytoma, but this depends on appropriate reference intervals. Upper cut-offs set too high compromise diagnostic sensitivity, whereas set too low, false-positives are a problem. This study aimed to establish optimal reference intervals for plasma normetanephrine and metanephrine. Blood samples were collected in the supine position from 1226 subjects, aged 5-84 y, including 116 children, 575 normotensive and hypertensive adults and 535 patients in whom phaeochromocytoma was ruled out. Reference intervals were examined according to age and gender. Various models were examined to optimize upper cut-offs according to estimates of diagnostic sensitivity and specificity in a separate validation group of 3888 patients tested for phaeochromocytoma, including 558 with confirmed disease. Plasma metanephrine, but not normetanephrine, was higher (P < 0.001) in men than in women, but reference intervals did not differ. Age showed a positive relationship (P < 0.0001) with plasma normetanephrine and a weaker relationship (P = 0.021) with metanephrine. Upper cut-offs of reference intervals for normetanephrine increased from 0.47 nmol/L in children to 1.05 nmol/L in subjects over 60 y. A curvilinear model for age-adjusted compared with fixed upper cut-offs for normetanephrine, together with a higher cut-off for metanephrine (0.45 versus 0.32 nmol/L), resulted in a substantial gain in diagnostic specificity from 88.3% to 96.0% with minimal loss in diagnostic sensitivity from 93.9% to 93.6%. These data establish age-adjusted cut-offs of reference intervals for plasma normetanephrine and optimized cut-offs for metanephrine useful for minimizing false-positive results.

  7. Reference intervals for plasma free metanephrines with an age adjustment for normetanephrine for optimized laboratory testing of phaeochromocytoma

    PubMed Central

    Eisenhofer, Graeme; Lattke, Peter; Herberg, Maria; Siegert, Gabriele; Qin, Nan; Därr, Roland; Hoyer, Jana; Villringer, Arno; Prejbisz, Aleksander; Januszewicz, Andrzej; Remaley, Alan; Martucci, Victoria; Pacak, Karel; Ross, H Alec; Sweep, Fred C G J; Lenders, Jacques W M

    2016-01-01

    Background Measurements of plasma normetanephrine and metanephrine provide a useful diagnostic test for phaeochromocytoma, but this depends on appropriate reference intervals. Upper cut-offs set too high compromise diagnostic sensitivity, whereas set too low, false-positives are a problem. This study aimed to establish optimal reference intervals for plasma normetanephrine and metanephrine. Methods Blood samples were collected in the supine position from 1226 subjects, aged 5–84 y, including 116 children, 575 normotensive and hypertensive adults and 535 patients in whom phaeochromocytoma was ruled out. Reference intervals were examined according to age and gender. Various models were examined to optimize upper cut-offs according to estimates of diagnostic sensitivity and specificity in a separate validation group of 3888 patients tested for phaeochromocytoma, including 558 with confirmed disease. Results Plasma metanephrine, but not normetanephrine, was higher (P < 0.001) in men than in women, but reference intervals did not differ. Age showed a positive relationship (P < 0.0001) with plasma normetanephrine and a weaker relationship (P = 0.021) with metanephrine. Upper cut-offs of reference intervals for normetanephrine increased from 0.47 nmol/L in children to 1.05 nmol/L in subjects over 60 y. A curvilinear model for age-adjusted compared with fixed upper cut-offs for normetanephrine, together with a higher cut-off for metanephrine (0.45 versus 0.32 nmol/L), resulted in a substantial gain in diagnostic specificity from 88.3% to 96.0% with minimal loss in diagnostic sensitivity from 93.9% to 93.6%. Conclusions These data establish age-adjusted cut-offs of reference intervals for plasma normetanephrine and optimized cut-offs for metanephrine useful for minimizing false-positive results. PMID:23065528

  8. Reference intervals and allometric scaling of two-dimensional echocardiographic measurements in 150 healthy cats.

    PubMed

    Karsten, Schober; Stephanie, Savino; Vedat, Yildiz

    2017-11-10

    The objective of the study was to evaluate the effects of body weight (BW), breed, and sex on two-dimensional (2D) echocardiographic measures, reference ranges, and prediction intervals using allometrically-scaled data of left atrial (LA) and left ventricular (LV) size and LV wall thickness in healthy cats. Study type was retrospective, observational, and clinical cohort. 150 healthy cats were enrolled and 2D echocardiograms analyzed. LA diameter, LV wall thickness, and LV dimension were quantified using three different imaging views. The effect of BW, breed, sex, age, and interaction (BW*sex) on echocardiographic variables was assessed using univariate and multivariate regression and linear mixed model analysis. Standard (using raw data) and allometrically scaled (Y=a × M b ) reference intervals and prediction intervals were determined. BW had a significant (P<0.05) independent effect on 2D variables whereas breed, sex, and age did not. There were clinically relevant differences between reference intervals using mean ± 2SD of raw data and mean and 95% prediction interval of allometrically-scaled variables, most prominent in larger (>6 kg) and smaller (<3 kg) cats. A clinically relevant difference between thickness of the interventricular septum (IVS) and dimension of the LV posterior wall (LVPW) was identified. In conclusion, allometric scaling and BW-based 95% prediction intervals should be preferred over conventional 2D echocardiographic reference intervals in cats, in particular in small and large cats. These results are particularly relevant to screening examinations for feline hypertrophic cardiomyopathy.

  9. Resampling methods in Microsoft Excel® for estimating reference intervals

    PubMed Central

    Theodorsson, Elvar

    2015-01-01

    Computer- intensive resampling/bootstrap methods are feasible when calculating reference intervals from non-Gaussian or small reference samples. Microsoft Excel® in version 2010 or later includes natural functions, which lend themselves well to this purpose including recommended interpolation procedures for estimating 2.5 and 97.5 percentiles.
The purpose of this paper is to introduce the reader to resampling estimation techniques in general and in using Microsoft Excel® 2010 for the purpose of estimating reference intervals in particular.
Parametric methods are preferable to resampling methods when the distributions of observations in the reference samples is Gaussian or can transformed to that distribution even when the number of reference samples is less than 120. Resampling methods are appropriate when the distribution of data from the reference samples is non-Gaussian and in case the number of reference individuals and corresponding samples are in the order of 40. At least 500-1000 random samples with replacement should be taken from the results of measurement of the reference samples. PMID:26527366

  10. Resampling methods in Microsoft Excel® for estimating reference intervals.

    PubMed

    Theodorsson, Elvar

    2015-01-01

    Computer-intensive resampling/bootstrap methods are feasible when calculating reference intervals from non-Gaussian or small reference samples. Microsoft Excel® in version 2010 or later includes natural functions, which lend themselves well to this purpose including recommended interpolation procedures for estimating 2.5 and 97.5 percentiles. 
The purpose of this paper is to introduce the reader to resampling estimation techniques in general and in using Microsoft Excel® 2010 for the purpose of estimating reference intervals in particular.
 Parametric methods are preferable to resampling methods when the distributions of observations in the reference samples is Gaussian or can transformed to that distribution even when the number of reference samples is less than 120. Resampling methods are appropriate when the distribution of data from the reference samples is non-Gaussian and in case the number of reference individuals and corresponding samples are in the order of 40. At least 500-1000 random samples with replacement should be taken from the results of measurement of the reference samples.

  11. Predictive value and efficiency of laboratory testing.

    PubMed

    Galen, R S

    1980-11-01

    Literature on determining reference values and reference intervals on "normal" or "healthy" individuals is abundant. It is impossible, however, to evaluate a data set of reference values and select a suitable reference interval that will be meaningful for the practice of medicine. The reference interval, no matter how derived statistically, tells us nothing about disease. This is the main reason the concepts of "normal values" have failed us and why "reference values" will prove similarly disappointing. By studying these same constituents in a variety of disease states as well, it will be possible to select "referent values" that will make the test procedure meaningful for diagnostic purposes. In order to obtain meaningful referent values for predicting disease, it is necessary to study not only the "healthy" reference population, but patients with the disease in question, and patients who are free of the disease in question but who have other diseases. Studies of this type are not frequently found for laboratory tests that are in common use today.

  12. Sex-specific reference intervals of hematologic and biochemical analytes in Sprague-Dawley rats using the nonparametric rank percentile method.

    PubMed

    He, Qili; Su, Guoming; Liu, Keliang; Zhang, Fangcheng; Jiang, Yong; Gao, Jun; Liu, Lida; Jiang, Zhongren; Jin, Minwu; Xie, Huiping

    2017-01-01

    Hematologic and biochemical analytes of Sprague-Dawley rats are commonly used to determine effects that were induced by treatment and to evaluate organ dysfunction in toxicological safety assessments, but reference intervals have not been well established for these analytes. Reference intervals as presently defined for these analytes in Sprague-Dawley rats have not used internationally recommended statistical method nor stratified by sex. Thus, we aimed to establish sex-specific reference intervals for hematologic and biochemical parameters in Sprague-Dawley rats according to Clinical and Laboratory Standards Institute C28-A3 and American Society for Veterinary Clinical Pathology guideline. Hematology and biochemistry blood samples were collected from 500 healthy Sprague-Dawley rats (250 males and 250 females) in the control groups. We measured 24 hematologic analytes with the Sysmex XT-2100i analyzer, 9 biochemical analytes with the Olympus AU400 analyzer. We then determined statistically relevant sex partitions and calculated reference intervals, including corresponding 90% confidence intervals, using nonparametric rank percentile method. We observed that most hematologic and biochemical analytes of Sprague-Dawley rats were significantly influenced by sex. Males had higher hemoglobin, hematocrit, red blood cell count, red cell distribution width, mean corpuscular volume, mean corpuscular hemoglobin, white blood cell count, neutrophils, lymphocytes, monocytes, percentage of neutrophils, percentage of monocytes, alanine aminotransferase, aspartate aminotransferase, and triglycerides compared to females. Females had higher mean corpuscular hemoglobin concentration, plateletcrit, platelet count, eosinophils, percentage of lymphocytes, percentage of eosinophils, creatinine, glucose, total cholesterol and urea compared to males. Sex partition was required for most hematologic and biochemical analytes in Sprague-Dawley rats. We established sex-specific reference intervals, including corresponding 90% confidence intervals, for Sprague-Dawley rats. Understanding the significant discrepancies in hematologic and biochemical analytes between male and female Sprague-Dawley rats provides important insight into physiological effects in test rats. Establishment of locally sex-specific reference intervals allows a more precise evaluation of animal quality and experimental results of Sprague-Dawley rats in our toxicology safety assessment.

  13. Prophylactic and immune modulatory influences of Nigella sativa Linn. in broilers exposed to biological challenge

    PubMed Central

    Soliman, Essam S.; Hamad, Rania T.; Ahmed, Amira

    2017-01-01

    Background and Aim: Prophylaxis and disease prevention is an essential strategy among biorisk management in poultry farms that stimulate and maintain the birds’ immunity. The aim of this study was to investigate the prophylactic, and immune-stimulant influence of Nigella sativa Linn. in broilers under biological stress. Materials and Methods: A total of 250 1-day-old (ross) chicks were divided into 5 groups; four of which were supplemented with 1.4%, 2.8%, 4.2%, and 5.6% N. sativa Linn., respectively. The four supplemented groups were challenged with Escherichia coli O157:H7 1.5×108 at a 14th day old. A total of 1050 samples (150 serum, 150 swab, and 750 organ samples) were collected and examined. Results: A highly significant increase (p<0.01) in 5.6% N. sativa Linn. supplemented group in performance traits (body weight, weight gain, and performance index), biochemical parameters (proteinogram, liver enzymes, and creatinine), immunoglobulins concentration, and immune organs’ weight. Meanwile, liver showed improvement of histoarchitecture without fibrosis. Heart showed a mild pericarditis with a mild degree of hydropic degeneration. Bursa, thymus, and spleen showed lymphoid hyperplasia. Conclusion: A concentration of 5.6% N. sativa Linn. in broiler’s feed can improve the immune response and subsequent resistance of broilers against diseases. PMID:29391685

  14. Complex reference values for endocrine and special chemistry biomarkers across pediatric, adult, and geriatric ages: establishment of robust pediatric and adult reference intervals on the basis of the Canadian Health Measures Survey.

    PubMed

    Adeli, Khosrow; Higgins, Victoria; Nieuwesteeg, Michelle; Raizman, Joshua E; Chen, Yunqi; Wong, Suzy L; Blais, David

    2015-08-01

    Defining laboratory biomarker reference values in a healthy population and understanding the fluctuations in biomarker concentrations throughout life and between sexes are critical to clinical interpretation of laboratory test results in different disease states. The Canadian Health Measures Survey (CHMS) has collected blood samples and health information from the Canadian household population. In collaboration with the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER), the data have been analyzed to determine reference value distributions and reference intervals for several endocrine and special chemistry biomarkers in pediatric, adult, and geriatric age groups. CHMS collected data and blood samples from thousands of community participants aged 3 to 79 years. We used serum samples to measure 13 immunoassay-based special chemistry and endocrine markers. We assessed reference value distributions and, after excluding outliers, calculated age- and sex-specific reference intervals, along with corresponding 90% CIs, according to CLSI C28-A3 guidelines. We observed fluctuations in biomarker reference values across the pediatric, adult, and geriatric age range, with stratification required on the basis of age for all analytes. Additional sex partitions were required for apolipoprotein AI, homocysteine, ferritin, and high sensitivity C-reactive protein. The unique collaboration between CALIPER and CHMS has enabled, for the first time, a detailed examination of the changes in various immunochemical markers that occur in healthy individuals of different ages. The robust age- and sex-specific reference intervals established in this study provide insight into the complex biological changes that take place throughout development and aging and will contribute to improved clinical test interpretation. © 2015 American Association for Clinical Chemistry.

  15. Reference intervals for serum lipids and prevalence of dyslipidaemia in 6-12-year-old children: The Health Oriented Pedagogical Project (HOPP).

    PubMed

    Strand, Martin Frank; Fredriksen, Per Morten; Hjelle, Ole Petter; Lindberg, Morten

    2018-05-01

    Elevated serum lipid concentrations in childhood are thought to be risk factors for the development of cardiovascular disease later in life. The present study aims to provide age- and gender-related reference intervals for total cholesterol (TC), high-density lipoprotein (HDL) cholesterol, and non-HDL cholesterol in healthy school children. We also investigated the prevalence of dyslipidaemia using the published criteria for these biomarkers. Venous blood and anthropometric data were collected from 1340 children in the HOPP study, aged between 6 and 12 years. Age- and gender-related reference intervals (2.5th and 97.5th percentiles) were established according to the IFCC recommendations, using the software RefVal 4.10. Gender differences were observed for total cholesterol and non-HDL cholesterol, but not for HDL cholesterol. Age differences were observed for total cholesterol. The reference intervals were in the range of 3.1-5.9 mmol/L for total cholesterol, 1.0-2.4 mmol/L for HDL cholesterol and 1.4-4.2 mmol/L for non-HDL cholesterol. Dyslipidaemia prevalence was as follows: increased TC 9.6%, decreased HDL 1.6%, and increased non-HDL 5.6%. Age- and gender-related reference intervals in a Norwegian population are similar to those reported in other countries. The prevalence of dyslipidaemia among Norwegian children is significant, emphasising the importance of appropriate reference intervals in clinical practice.

  16. Reference Values for TSH and Free Thyroid Hormones in Healthy Pregnant Women in Poland: A Prospective, Multicenter Study.

    PubMed

    Kostecka-Matyja, Marta; Fedorowicz, Anna; Bar-Andziak, Ewa; Bednarczuk, Tomasz; Buziak-Bereza, Monika; Dumnicka, Paulina; Górska, Maria; Krasnodębska, Małgorzata; Niedźwiedzka, Beata; Pach, Dorota; Ruchała, Marek; Siewko, Katarzyna; Solnica, Bogdan; Sowiński, Jerzy; Szelachowska, Małgorzata; Trofimiuk-Müldner, Małgorzata; Wachowiak-Ochmańska, Katarzyna; Hubalewska-Dydejczyk, Alicja

    2017-04-01

    The diagnosis and treatment of thyroid diseases in pregnant women remains a challenge. Various medical associations recommend establishing the reference intervals for thyroid hormones by a local laboratory. Considering differences within geophysical, socioeconomic conditions, and iodine prophylaxis in various populations, it is advisable to assess reference intervals for thyroid hormones specific to a region of residence. The objective was to assess trimester-specific reference intervals for TSH, fT 3 , and fT 4 for pregnant women in the Polish population. We conducted a prospective study in 4 centers representing different regions of Poland (Krakow, Warsaw, Poznan, and Bialystok). Our study included consecutive, healthy pregnant women (172 patients), with an age range of 27-47 years. All women had a negative history for thyroid diseases, normal thyroid peroxidase antibody levels, and proper iodine prophylaxis. All newborns had TSH levels in the appropriate reference range. Serum TSH, fT 3 , fT 4 , and thyroid-peroxidase antibodies were measured in each trimester. The reference intervals were calculated using the percentile method, as recommended by the International Federation of Clinical Chemistry. The reference values calculated were 0.009-3.177, 0.05-3.442, and 0.11-3.53 mIU/L for TSH; 3.63-6.55, 3.29-5.45, and 3.1-5.37 pmol/L for fT 3 ; and 11.99-21.89, 10.46-16.67, and 8.96-17.23 pmol/L for fT 4 in consecutive trimesters of pregnancy. Reference intervals for pregnant women when compared to the general population showed a lower concentration of TSH in every trimester of pregnancy and lower fT 4 in the 2nd and 3rd trimesters. Using appropriate trimester-specific reference intervals may improve care of pregnant women by preventing misdiagnosis and inadequate treatment.

  17. Serum prolactin revisited: parametric reference intervals and cross platform evaluation of polyethylene glycol precipitation-based methods for discrimination between hyperprolactinemia and macroprolactinemia.

    PubMed

    Overgaard, Martin; Pedersen, Susanne Møller

    2017-10-26

    Hyperprolactinemia diagnosis and treatment is often compromised by the presence of biologically inactive and clinically irrelevant higher-molecular-weight complexes of prolactin, macroprolactin. The objective of this study was to evaluate the performance of two macroprolactin screening regimes across commonly used automated immunoassay platforms. Parametric total and monomeric gender-specific reference intervals were determined for six immunoassay methods using female (n=96) and male sera (n=127) from healthy donors. The reference intervals were validated using 27 hyperprolactinemic and macroprolactinemic sera, whose presence of monomeric and macroforms of prolactin were determined using gel filtration chromatography (GFC). Normative data for six prolactin assays included the range of values (2.5th-97.5th percentiles). Validation sera (hyperprolactinemic and macroprolactinemic; n=27) showed higher discordant classification [mean=2.8; 95% confidence interval (CI) 1.2-4.4] for the monomer reference interval method compared to the post-polyethylene glycol (PEG) recovery cutoff method (mean=1.8; 95% CI 0.8-2.8). The two monomer/macroprolactin discrimination methods did not differ significantly (p=0.089). Among macroprolactinemic sera evaluated by both discrimination methods, the Cobas and Architect/Kryptor prolactin assays showed the lowest and the highest number of misclassifications, respectively. Current automated immunoassays for prolactin testing require macroprolactin screening methods based on PEG precipitation in order to discriminate truly from falsely elevated serum prolactin. While the recovery cutoff and monomeric reference interval macroprolactin screening methods demonstrate similar discriminative ability, the latter method also provides the clinician with an easy interpretable monomeric prolactin concentration along with a monomeric reference interval.

  18. Pediatric reference intervals for random urine calcium, phosphorus and total protein.

    PubMed

    Slev, Patricia R; Bunker, Ashley M; Owen, William E; Roberts, William L

    2010-09-01

    The aim of this study was to establish age appropriate reference intervals for calcium (Ca), phosphorus (P) and total protein (UTP) in random urine samples. All analytes were measured using the Roche MODULAR P analyzer and normalized to creatinine (Cr). Our study cohort consisted of 674 boys and 728 girls between 7 and 17 years old (y.o.), which allowed us to determine the central 95% reference intervals with 90% confidence intervals by non-parametric analysis partitioned by both gender and 2-year age intervals for each analyte [i.e. boys in age group 7-9 years (7-9 boys); girls in age group 7-9 years (7-9 girls), etc.]. Results for the upper limits of the central 95% reference interval were: for Ca/Cr, 0.27 (16,17 y.o.) to 0.46 mg/mg (7-9 y.o.) for the girls and 0.26 (16,17 y.o.) to 0.43 mg/mg (7-9 y.o.) for the boys; for P/Cr, 0.85 (16,17 y.o.) to 1.44 mg/mg (7-9 y.o.) for the girls and 0.87 (16,17 y.o.) to 1.68 mg/mg (7-9 y.o.) for the boys; for UTP/Cr, 0.30 (7-9 y.o.) to 0.34 mg/mg (10-12 y.o.) for the girls and 0.19 (16,17, y.o.) to 0.26 mg/mg (13-15 y.o.) for the boys. Upper reference limits decreased with increasing age, and age was a statistically significant variable for all analytes. Eight separate age- and gender-specific reference intervals are proposed per analyte.

  19. Off-set stabilizer for comparator output

    DOEpatents

    Lunsford, James S.

    1991-01-01

    A stabilized off-set voltage is input as the reference voltage to a comparator. In application to a time-interval meter, the comparator output generates a timing interval which is independent of drift in the initial voltage across the timing capacitor. A precision resistor and operational amplifier charge a capacitor to a voltage which is precisely offset from the initial voltage. The capacitance of the reference capacitor is selected so that substantially no voltage drop is obtained in the reference voltage applied to the comparator during the interval to be measured.

  20. CLSI-based transference and verification of CALIPER pediatric reference intervals for 29 Ortho VITROS 5600 chemistry assays.

    PubMed

    Higgins, Victoria; Truong, Dorothy; Woroch, Amy; Chan, Man Khun; Tahmasebi, Houman; Adeli, Khosrow

    2018-03-01

    Evidence-based reference intervals (RIs) are essential to accurately interpret pediatric laboratory test results. To fill gaps in pediatric RIs, the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) project developed an age- and sex-specific pediatric RI database based on healthy pediatric subjects. Originally established for Abbott ARCHITECT assays, CALIPER RIs were transferred to assays on Beckman, Roche, Siemens, and Ortho analytical platforms. This study provides transferred reference intervals for 29 biochemical assays for the Ortho VITROS 5600 Chemistry System (Ortho). Based on Clinical Laboratory Standards Institute (CLSI) guidelines, a method comparison analysis was performed by measuring approximately 200 patient serum samples using Abbott and Ortho assays. The equation of the line of best fit was calculated and the appropriateness of the linear model was assessed. This equation was used to transfer RIs from Abbott to Ortho assays. Transferred RIs were verified using 84 healthy pediatric serum samples from the CALIPER cohort. RIs for most chemistry analytes successfully transferred from Abbott to Ortho assays. Calcium and CO 2 did not meet statistical criteria for transference (r 2 <0.70). Of the 32 transferred reference intervals, 29 successfully verified with approximately 90% of results from reference samples falling within transferred confidence limits. Transferred RIs for total bilirubin, magnesium, and LDH did not meet verification criteria and are not reported. This study broadens the utility of the CALIPER pediatric RI database to laboratories using Ortho VITROS 5600 biochemical assays. Clinical laboratories should verify CALIPER reference intervals for their specific analytical platform and local population as recommended by CLSI. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  1. Evaluation of an anal sac adenocarcinoma tumor in a Spitz dog.

    PubMed

    Javanbakht, Javad; Tavassoli, Abbas; Sabbagh, Atefeh; Hassan, Mehdy Aghamohammmad; Samakkhah, Shohreh Alian; Shafiee, Radmehr; Lakzian, Ali; Ghalee, Vahideh Rahmani; Gharebagh, Sonia Shoja

    2013-01-01

    A 9-year-old emasculated male Spitz with tenesmus and constipation had a subcutaneous mass at the left ventral aspect of the anus with history of polyuria and polydipsia. A complete blood cell count, serum biochemistry panel, and urinalysis (cystocentesis sample) were evaluated. Abnormalities in the serum biochemistry panel included a mildly elevated serum cholesterol concentration (7.28 mmol/L; reference interval, 2.70-5.94 mmol/L), increased serum alkaline phosphatase activity (184 U/L; reference interval, 9-90 U/L), alanine transaminase (122 U/L; reference interval, 5-60 U/L) activity and aspartate aminotransferase (80 U/L; reference interval, 5-55 U/L) activity, severe increased total calcium concentration (16.3 mg/dL; reference interval, 8.2-12.4 mg/dL or 9.3-11.4 mg/dL), and decreased total calcium concentration (3.4 mg/dL, reference interval, 2.5-5.6mg/dL). Furthermore, testing revealed an increased intact parathyroid hormone concentration (38.6 pmol/L; reference interval, 3-17 pmol/L). On cytologic and histopathologic examinations, various types of cells were observed. Most of the cells were oval to polygonal and had elliptical or elongate nuclei and a moderate amount of pale to basophilic cytoplasm. The remaining cells had round to oval nuclei and pale to basophilic cytoplasm. Cells of both types were loosely adhered to each other and were arranged in rosette-like structures. Both neoplastic cell types had fine homogenous chromatin and either a small indistinct nucleolus or no visible nucleolus. Mild anisokaryosis and anisocytosis were observed. Histologically, the mass consists of glandular structures formed by cuboidal cells admixed with bundles of spindle cells. Based on location and histologic features, the final diagnosis was adenocarcinoma of the apocrine gland of the anal sac, which should be included as a cytologic differential diagnosis when spindle cells and typical epithelial cells are observed in masses in the region of the anal sac of dogs.

  2. Reference intervals for plasma-free amino acid in a Japanese population.

    PubMed

    Yamamoto, Hiroyuki; Kondo, Kazuhiro; Tanaka, Takayuki; Muramatsu, Takahiko; Yoshida, Hiroo; Imaizumi, Akira; Nagao, Kenji; Noguchi, Yasushi; Miyano, Hiroshi

    2016-05-01

    Plasma amino acid concentrations vary with various diseases. Although reference intervals are useful in daily clinical practice, no reference intervals have been reported for plasma amino acids in a large Japanese population. Reference individuals were selected from 7685 subjects examined with the Japanese Ningen Dock in 2008. A total of 1890 individuals were selected based on exclusion criteria, and the reference samples were selected after the outlier samples for each amino acid concentration were excluded. The lower limit of the reference intervals for the plasma amino acid concentrations was set at the 2.5th percentile and the upper limit at the 97.5th percentile. By use of the nested analysis of variance, we analysed a large dataset of plasma samples and the effects of background factors (sex, age and body mass index [BMI]) on the plasma amino acid concentrations. Most amino acid concentrations were related to sex, especially those of branched-chained amino acid. The citrulline, glutamine, ornithine and lysine concentrations were related to age. The glutamate concentration was related to body mass index. The concentrations of most amino acids are more strongly related to sex than to age or body mass index. Our results indicate that the reference intervals for plasma amino acid concentrations should be stratified by sex when the background factors of age and body mass index are considered. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  3. Age and sex variation in serum albumin concentration: an observational study.

    PubMed

    Weaving, Gary; Batstone, Gifford F; Jones, Richard G

    2016-01-01

    In the UK, a common reference interval for serum albumin is widely used irrespective of age or sex. Implicit in this is that laboratories produce analytically similar results. This paper challenges the validity of this approach. A three-week collection of results sent to all primary care centres in England has been analysed by age, sex and laboratory. In all, 1,079,193 serum albumin reports were included in this analysis. The mean population serum albumin concentration increases to peak at around age 20 years and then decreases with increasing age. Values in females decrease more rapidly but become close to male values at 60 years. The variation between laboratories was large and potentially clinically significant. Reference intervals for serum albumin should be stratified by age and sex. Until there is greater methodological standardization, laboratories should determine their own reference intervals and not accept a single consensus reference interval. © The Author(s) 2015.

  4. Hematology and plasma chemistry reference intervals for cultured tilapia (Oreochromis hybrid).

    PubMed

    Hrubec, Terry C.; Cardinale, Jenifer L.; Smith, Stephen A.

    2000-01-01

    Tilapia are a commonly aquacultured fish yet little is known about their normal physiology and response to disease. In this study we determined the results of complete hematologic (n=40) and plasma biochemical profiles (n=63) in production tilapia (Oreochromis hybrids). The fish were raised in recirculating systems with a high stocking density (120 g/L), and were in the middle of a 15-month production cycle. Blood was analyzed using standard techniques, and reference intervals were determined using nonparametric methods. Non-production tilapia (n=15) from low-density tanks (4 g/L) also were sampled; the clinical chemistry results were compared to reference intervals from the fish raised in high-density tanks. Differences were noted in plasma protein, calcium and phosphorus concentrations, such that reference intervals for high-density production tilapia were not applicable to fish raised under different environmental and management conditions.

  5. A multicenter study on PIVKA reference interval of healthy population and establishment of PIVKA cutoff value for hepatocellular carcinoma diagnosis in China.

    PubMed

    Qin, X; Tang, G; Gao, R; Guo, Z; Liu, Z; Yu, S; Chen, M; Tao, Z; Li, S; Liu, M; Wang, L; Hou, L; Xia, L; Cheng, X; Han, J; Qiu, L

    2017-08-01

    The aim of this study was to investigate the reference interval of protein-induced vitamin K absence or antagonist-II (PIVKA-II) in China population and to evaluate its medical decision level for hepatocellular carcinoma (HCC) diagnosis. To determine the reference range for Chinese individuals, a total of 855 healthy subjects in five typical regions of China were enrolled in this study to obtain a 95% reference interval. In a case-control study which recruited the subjects diagnosed with HCC, metastatic liver cancer, bile duct cancer, hepatitis, cirrhosis, other benign liver diseases and the subjects administrated anticoagulant, receiver operating characteristic analysis was used to determine PIVKA-II cutoff value for a medical decision. The concentration of PIVKA-II had no relationship with age or gender and that region was a significant factor associated with the level of PIVKA-II. The 95% reference interval determined in this study for PIVKA-II in Chinese healthy individuals was 28 mAU/mL, and the cutoff value which to distinguish patients with HCC from disease control groups is 36.5 mAU/mL. In clinical applications, it is recommended that each laboratory chooses their own reference interval based on the regional population study or cutoff value for disease diagnosis. © 2017 John Wiley & Sons Ltd.

  6. Reference Value Advisor: a new freeware set of macroinstructions to calculate reference intervals with Microsoft Excel.

    PubMed

    Geffré, Anne; Concordet, Didier; Braun, Jean-Pierre; Trumel, Catherine

    2011-03-01

    International recommendations for determination of reference intervals have been recently updated, especially for small reference sample groups, and use of the robust method and Box-Cox transformation is now recommended. Unfortunately, these methods are not included in most software programs used for data analysis by clinical laboratories. We have created a set of macroinstructions, named Reference Value Advisor, for use in Microsoft Excel to calculate reference limits applying different methods. For any series of data, Reference Value Advisor calculates reference limits (with 90% confidence intervals [CI]) using a nonparametric method when n≥40 and by parametric and robust methods from native and Box-Cox transformed values; tests normality of distributions using the Anderson-Darling test and outliers using Tukey and Dixon-Reed tests; displays the distribution of values in dot plots and histograms and constructs Q-Q plots for visual inspection of normality; and provides minimal guidelines in the form of comments based on international recommendations. The critical steps in determination of reference intervals are correct selection of as many reference individuals as possible and analysis of specimens in controlled preanalytical and analytical conditions. Computing tools cannot compensate for flaws in selection and size of the reference sample group and handling and analysis of samples. However, if those steps are performed properly, Reference Value Advisor, available as freeware at http://www.biostat.envt.fr/spip/spip.php?article63, permits rapid assessment and comparison of results calculated using different methods, including currently unavailable methods. This allows for selection of the most appropriate method, especially as the program provides the CI of limits. It should be useful in veterinary clinical pathology when only small reference sample groups are available. ©2011 American Society for Veterinary Clinical Pathology.

  7. CLSI-derived hematology and biochemistry reference intervals for healthy adults in eastern and southern Africa.

    PubMed

    Karita, Etienne; Ketter, Nzeera; Price, Matt A; Kayitenkore, Kayitesi; Kaleebu, Pontiano; Nanvubya, Annet; Anzala, Omu; Jaoko, Walter; Mutua, Gaudensia; Ruzagira, Eugene; Mulenga, Joseph; Sanders, Eduard J; Mwangome, Mary; Allen, Susan; Bwanika, Agnes; Bahemuka, Ubaldo; Awuondo, Ken; Omosa, Gloria; Farah, Bashir; Amornkul, Pauli; Birungi, Josephine; Yates, Sarah; Stoll-Johnson, Lisa; Gilmour, Jill; Stevens, Gwynn; Shutes, Erin; Manigart, Olivier; Hughes, Peter; Dally, Len; Scott, Janet; Stevens, Wendy; Fast, Pat; Kamali, Anatoli

    2009-01-01

    Clinical laboratory reference intervals have not been established in many African countries, and non-local intervals are commonly used in clinical trials to screen and monitor adverse events (AEs) among African participants. Using laboratory reference intervals derived from other populations excludes potential trial volunteers in Africa and makes AE assessment challenging. The objective of this study was to establish clinical laboratory reference intervals for 25 hematology, immunology and biochemistry values among healthy African adults typical of those who might join a clinical trial. Equal proportions of men and women were invited to participate in a cross sectional study at seven clinical centers (Kigali, Rwanda; Masaka and Entebbe, Uganda; two in Nairobi and one in Kilifi, Kenya; and Lusaka, Zambia). All laboratories used hematology, immunology and biochemistry analyzers validated by an independent clinical laboratory. Clinical and Laboratory Standards Institute guidelines were followed to create study consensus intervals. For comparison, AE grading criteria published by the U.S. National Institute of Allergy and Infectious Diseases Division of AIDS (DAIDS) and other U.S. reference intervals were used. 2,990 potential volunteers were screened, and 2,105 (1,083 men and 1,022 women) were included in the analysis. While some significant gender and regional differences were observed, creating consensus African study intervals from the complete data was possible for 18 of the 25 analytes. Compared to reference intervals from the U.S., we found lower hematocrit and hemoglobin levels, particularly among women, lower white blood cell and neutrophil counts, and lower amylase. Both genders had elevated eosinophil counts, immunoglobulin G, total and direct bilirubin, lactate dehydrogenase and creatine phosphokinase, the latter being more pronounced among women. When graded against U.S. -derived DAIDS AE grading criteria, we observed 774 (35.3%) volunteers with grade one or higher results; 314 (14.9%) had elevated total bilirubin, and 201 (9.6%) had low neutrophil counts. These otherwise healthy volunteers would be excluded or would require special exemption to participate in many clinical trials. To accelerate clinical trials in Africa, and to improve their scientific validity, locally appropriate reference ranges should be used. This study provides ranges that will inform inclusion criteria and evaluation of adverse events for studies in these regions of Africa.

  8. Establishment of reference intervals for plasma protein electrophoresis in Indo-Pacific green sea turtles, Chelonia mydas.

    PubMed

    Flint, Mark; Matthews, Beren J; Limpus, Colin J; Mills, Paul C

    2015-01-01

    Biochemical and haematological parameters are increasingly used to diagnose disease in green sea turtles. Specific clinical pathology tools, such as plasma protein electrophoresis analysis, are now being used more frequently to improve our ability to diagnose disease in the live animal. Plasma protein reference intervals were calculated from 55 clinically healthy green sea turtles using pulsed field electrophoresis to determine pre-albumin, albumin, α-, β- and γ-globulin concentrations. The estimated reference intervals were then compared with data profiles from clinically unhealthy turtles admitted to a local wildlife hospital to assess the validity of the derived intervals and identify the clinically useful plasma protein fractions. Eighty-six per cent {19 of 22 [95% confidence interval (CI) 65-97]} of clinically unhealthy turtles had values outside the derived reference intervals, including the following: total protein [six of 22 turtles or 27% (95% CI 11-50%)], pre-albumin [two of five, 40% (95% CI 5-85%)], albumin [13 of 22, 59% (95% CI 36-79%)], total albumin [13 of 22, 59% (95% CI 36-79%)], α- [10 of 22, 45% (95% CI 24-68%)], β- [two of 10, 20% (95% CI 3-56%)], γ- [one of 10, 10% (95% CI 0.3-45%)] and β-γ-globulin [one of 12, 8% (95% CI 0.2-38%)] and total globulin [five of 22, 23% (8-45%)]. Plasma protein electrophoresis shows promise as an accurate adjunct tool to identify a disease state in marine turtles. This study presents the first reference interval for plasma protein electrophoresis in the Indo-Pacific green sea turtle.

  9. [Investigation of reference intervals of blood gas and acid-base analysis assays in China].

    PubMed

    Zhang, Lu; Wang, Wei; Wang, Zhiguo

    2015-10-01

    To investigate and analyze the upper and lower limits and their sources of reference intervals in blood gas and acid-base analysis assays. The data of reference intervals were collected, which come from the first run of 2014 External Quality Assessment (EQA) program in blood gas and acid-base analysis assays performed by National Center for Clinical Laboratories (NCCL). All the abnormal values and errors were eliminated. Data statistics was performed by SPSS 13.0 and Excel 2007 referring to upper and lower limits of reference intervals and sources of 7 blood gas and acid-base analysis assays, i.e. pH value, partial pressure of carbon dioxide (PCO2), partial pressure of oxygen (PO2), Na+, K+, Ca2+ and Cl-. Values were further grouped based on instrument system and the difference between each group were analyzed. There were 225 laboratories submitting the information on the reference intervals they had been using. The three main sources of reference intervals were National Guide to Clinical Laboratory Procedures [37.07% (400/1 079)], instructions of instrument manufactures [31.23% (337/1 079)] and instructions of reagent manufactures [23.26% (251/1 079)]. Approximately 35.1% (79/225) of the laboratories had validated the reference intervals they used. The difference of upper and lower limits in most assays among 7 laboratories was moderate, both minimum and maximum (i.e. the upper limits of pH value was 7.00-7.45, the lower limits of Na+ was 130.00-156.00 mmol/L), and mean and median (i.e. the upper limits of K+ was 5.04 mmol/L and 5.10 mmol/L, the upper limits of PCO2 was 45.65 mmHg and 45.00 mmHg, 1 mmHg = 0.133 kPa), as well as the difference in P2.5 and P97.5 between each instrument system group. It was shown by Kruskal-Wallis method that the P values of upper and lower limits of all the parameters were lower than 0.001, expecting the lower limits of Na+ with P value 0.029. It was shown by Mann-Whitney that the statistic differences were found among instrument system groups and between most of two instrument system groups in all assays. The difference of reference intervals of blood gas and acid-base analysis assays used in China laboratories is moderate, which is better than other specialties in clinical laboratories.

  10. Plasma creatinine in dogs: intra- and inter-laboratory variation in 10 European veterinary laboratories

    PubMed Central

    2011-01-01

    Background There is substantial variation in reported reference intervals for canine plasma creatinine among veterinary laboratories, thereby influencing the clinical assessment of analytical results. The aims of the study was to determine the inter- and intra-laboratory variation in plasma creatinine among 10 veterinary laboratories, and to compare results from each laboratory with the upper limit of its reference interval. Methods Samples were collected from 10 healthy dogs, 10 dogs with expected intermediate plasma creatinine concentrations, and 10 dogs with azotemia. Overlap was observed for the first two groups. The 30 samples were divided into 3 batches and shipped in random order by postal delivery for plasma creatinine determination. Statistical testing was performed in accordance with ISO standard methodology. Results Inter- and intra-laboratory variation was clinically acceptable as plasma creatinine values for most samples were usually of the same magnitude. A few extreme outliers caused three laboratories to fail statistical testing for consistency. Laboratory sample means above or below the overall sample mean, did not unequivocally reflect high or low reference intervals in that laboratory. Conclusions In spite of close analytical results, further standardization among laboratories is warranted. The discrepant reference intervals seem to largely reflect different populations used in establishing the reference intervals, rather than analytical variation due to different laboratory methods. PMID:21477356

  11. Serum reference interval of ARCHITECT alpha-fetoprotein in healthy Chinese Han adults: Sub-analysis of a prospective multi-center study.

    PubMed

    Yan, Cunling; Yang, Jia; Wei, Lianhua; Hu, Jian; Song, Jiaqi; Wang, Xiaoqin; Han, Ruilin; Huang, Ying; Zhang, Wei; Soh, Andrew; Beshiri, Agim; Fan, Zhuping; Zheng, Yijie; Chen, Wei

    2018-02-01

    Alpha-fetoprotein (AFP) has been widely used in clinical practice for decades. However, large-scale survey of serum reference interval for ARCHITECT AFP is still absent in Chinese population. This study aimed to measure serum AFP levels in healthy Chinese Han subjects, which is a sub-analysis of an ongoing prospective, cross-sectional, multi-center study (ClinicalTrials.gov Identifier: NCT03047603). This analysis included a total of 530 participants (41.43±12.14years of age on average, 48.49% males), enrolled from 5 regional centers. Serum AFP level was measured by ARCHITECT immunoassay. Statistical analysis was performed using SAS 9.4 and R software. AFP distribution did not show significant correlation with age or sex. The overall median and interquartile range of AFP was 2.87 (2.09, 3.83) ng/mL. AFP level did not show a trend of increasing with age. The new reference interval was 2.0-7.07ng/mL (LOQ- 97.5th percentiles). The reference interval for ARCHITECT AFP is updated with the data of adequate number of healthy Han adults. This new reference interval is more practical and applicable in Chinese adults. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. Echocardiographic assessments of longitudinal left ventricular function in healthy English Springer spaniels.

    PubMed

    Dickson, D; Shave, R; Rishniw, M; Patteson, M

    2017-08-01

    To establish reference intervals for echocardiographic measures of longitudinal left ventricular function in adult English Springer spaniel (ESS) dogs. This study involved 42 healthy adult ESS. Animals were prospectively recruited from a general practice population in the United Kingdom. Dogs were examined twice, at least 12 months apart, to exclude dogs with progressive cardiac disease. Mitral annular plane systolic excursion, tissue Doppler imaging mitral annular velocities and two-dimensional speckle-tracking echocardiographic left ventricular longitudinal strain and strain rate were measured. Intraoperator and intraobserver variability were examined and reference intervals were calculated. The potential effects of body weight, age and heart rate on these variables were examined. Intraoperator and intraobserver variability was <10% for all parameters except tissue Doppler imaging E' (the peak velocity of early diastolic mitral annular motion as determined by pulsed wave Doppler) and two-dimensional speckle-tracking echocardiographic variables, which were all <20%. Thirty-nine dogs were used to create reference intervals. Significant (but mostly weak) effects of age, heart rate and body weight on were detected. Reference intervals were similar to previously published values in different breeds. Breed specific reference intervals for measures of longitudinal left ventricular function in the ESS are presented. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Bias Assessment of General Chemistry Analytes using Commutable Samples.

    PubMed

    Koerbin, Gus; Tate, Jillian R; Ryan, Julie; Jones, Graham Rd; Sikaris, Ken A; Kanowski, David; Reed, Maxine; Gill, Janice; Koumantakis, George; Yen, Tina; St John, Andrew; Hickman, Peter E; Simpson, Aaron; Graham, Peter

    2014-11-01

    Harmonisation of reference intervals for routine general chemistry analytes has been a goal for many years. Analytical bias may prevent this harmonisation. To determine if analytical bias is present when comparing methods, the use of commutable samples, or samples that have the same properties as the clinical samples routinely analysed, should be used as reference samples to eliminate the possibility of matrix effect. The use of commutable samples has improved the identification of unacceptable analytical performance in the Netherlands and Spain. The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has undertaken a pilot study using commutable samples in an attempt to determine not only country specific reference intervals but to make them comparable between countries. Australia and New Zealand, through the Australasian Association of Clinical Biochemists (AACB), have also undertaken an assessment of analytical bias using commutable samples and determined that of the 27 general chemistry analytes studied, 19 showed sufficiently small between method biases as to not prevent harmonisation of reference intervals. Application of evidence based approaches including the determination of analytical bias using commutable material is necessary when seeking to harmonise reference intervals.

  14. Biochemical marker reference values across pediatric, adult, and geriatric ages: establishment of robust pediatric and adult reference intervals on the basis of the Canadian Health Measures Survey.

    PubMed

    Adeli, Khosrow; Higgins, Victoria; Nieuwesteeg, Michelle; Raizman, Joshua E; Chen, Yunqi; Wong, Suzy L; Blais, David

    2015-08-01

    Biological covariates such as age and sex can markedly influence biochemical marker reference values, but no comprehensive study has examined such changes across pediatric, adult, and geriatric ages. The Canadian Health Measures Survey (CHMS) collected comprehensive nationwide health information and blood samples from children and adults in the household population and, in collaboration with the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER), examined biological changes in biochemical markers from pediatric to geriatric age, establishing a comprehensive reference interval database for routine disease biomarkers. The CHMS collected health information, physical measurements, and biosamples (blood and urine) from approximately 12 000 Canadians aged 3-79 years and measured 24 biochemical markers with the Ortho Vitros 5600 FS analyzer or a manual microplate. By use of CLSI C28-A3 guidelines, we determined age- and sex-specific reference intervals, including corresponding 90% CIs, on the basis of specific exclusion criteria. Biochemical marker reference values exhibited dynamic changes from pediatric to geriatric age. Most biochemical markers required some combination of age and/or sex partitioning. Two or more age partitions were required for all analytes except bicarbonate, which remained constant throughout life. Additional sex partitioning was required for most biomarkers, except bicarbonate, total cholesterol, total protein, urine iodine, and potassium. Understanding the fluctuations in biochemical markers over a wide age range provides important insight into biological processes and facilitates clinical application of biochemical markers to monitor manifestation of various disease states. The CHMS-CALIPER collaboration addresses this important evidence gap and allows the establishment of robust pediatric and adult reference intervals. © 2015 American Association for Clinical Chemistry.

  15. Establishing pediatric reference intervals for 13 biochemical analytes derived from normal subjects in a pediatric endocrinology clinic in Korea.

    PubMed

    Cho, Sun-Mi; Lee, Sang-Guk; Kim, Ho Seong; Kim, Jeong-Ho

    2014-12-01

    Defining pediatric reference intervals is one of the most difficult tasks for laboratory physicians. The continuously changing physiology of growing children makes their laboratory values moving targets. In addition, ethnic and behavioral differences might also cause variations. The aim of this study was to establish age- and sex-specific partitioned reference intervals for 13 serum biochemical analytes in Korean children. A total of 2474 patients, girls aged 2-14 years and boys aged 2-16 years, who underwent a short stature workup but were diagnosed as normal at the Pediatric Endocrinology Clinic of Severance Hospital (Seoul, Korea) between September 2010 and June 2012 were included in this study. The levels of serum calcium, inorganic phosphorus, blood urea nitrogen, creatinine, uric acid, glucose, total cholesterol, total protein, albumin, alkaline phosphatase, aspartic aminotransferase, alanine aminotransferase, and total bilirubin were measured using a Hitachi 7600 analyzer (Hitachi High-Technologies Corporation, Tokyo, Japan). Reference intervals were partitioned according to sex or age subgroups using the Harris and Boyd method. Most analytes except calcium and albumin required partitioning either by sex or age. Age-specific partitioned reference intervals for alkaline phosphatase, creatinine, and total bilirubin were established for both males and females after being partitioned by sex. Additional age-specific partitioning of aspartic aminotransferase in females and total protein and uric acid in males was also required. Inorganic phosphorus, total cholesterol, alanine aminotransferase, blood urea nitrogen, and glucose were partitioned only by sex. This study provided updated age- and sex-specific pediatric reference intervals for 13 basic serum chemistry analytes from a sufficient number of healthy children by using a modern analytical chemistry platform. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  16. Screening for phaeochromocytoma and paraganglioma: impact of using supine reference intervals for plasma metanephrines with samples collected from fasted/seated patients.

    PubMed

    Casey, R; Griffin, T P; Wall, D; Dennedy, M C; Bell, M; O'Shea, P M

    2017-01-01

    Background The Endocrine Society Clinical Practice Guideline on Phaeochomocytoma and Paraganglioma recommends phlebotomy for plasma-free metanephrines with patients fasted and supine using appropriately defined reference intervals. Studies have shown higher diagnostic sensitivities using these criteria. Further, with seated-sampling protocols, for result interpretation, reference intervals that do not compromise diagnostic sensitivity should be employed. Objective To determine the impact on diagnostic performance and financial cost of using supine reference intervals for result interpretation with our current plasma-free metanephrines fasted/seated-sampling protocol. Methods We conducted a retrospective cohort study of patients who underwent screening for PPGL using plasma-free metanephrines from 2009 to 2014 at Galway University Hospitals. Plasma-free metanephrines were measured using liquid chromatography-tandem mass spectrometry. Supine thresholds for plasma normetanephrine and metanephrine set at 610 pmol/L and 310 pmol/L, respectively, were used. Results A total of 183 patients were evaluated. Mean age of participants was 53.4 (±16.3) years. Five of 183 (2.7%) patients had histologically confirmed PPGL (males, n=4). Using seated reference intervals for plasma-free metanephrines, diagnostic sensitivity and specificity were 100% and 98.9%, respectively, with two false-positive cases. Application of reference intervals established in subjects supine and fasted to this cohort gave diagnostic sensitivity of 100% with specificity of 74.7%. Financial analysis of each pretesting strategy demonstrated cost-equivalence (€147.27/patient). Conclusion Our cost analysis, together with the evidence that fasted/supine-sampling for plasma-free metanephrines, offers more reliable exclusion of PPGL mandates changing our current practice. This study highlights the important advantages of standardized diagnostic protocols for plasma-free metanephrines to ensure the highest diagnostic accuracy for investigation of PPGL.

  17. The use of regression analysis in determining reference intervals for low hematocrit and thrombocyte count in multiple electrode aggregometry and platelet function analyzer 100 testing of platelet function.

    PubMed

    Kuiper, Gerhardus J A J M; Houben, Rik; Wetzels, Rick J H; Verhezen, Paul W M; Oerle, Rene van; Ten Cate, Hugo; Henskens, Yvonne M C; Lancé, Marcus D

    2017-11-01

    Low platelet counts and hematocrit levels hinder whole blood point-of-care testing of platelet function. Thus far, no reference ranges for MEA (multiple electrode aggregometry) and PFA-100 (platelet function analyzer 100) devices exist for low ranges. Through dilution methods of volunteer whole blood, platelet function at low ranges of platelet count and hematocrit levels was assessed on MEA for four agonists and for PFA-100 in two cartridges. Using (multiple) regression analysis, 95% reference intervals were computed for these low ranges. Low platelet counts affected MEA in a positive correlation (all agonists showed r 2 ≥ 0.75) and PFA-100 in an inverse correlation (closure times were prolonged with lower platelet counts). Lowered hematocrit did not affect MEA testing, except for arachidonic acid activation (ASPI), which showed a weak positive correlation (r 2 = 0.14). Closure time on PFA-100 testing was inversely correlated with hematocrit for both cartridges. Regression analysis revealed different 95% reference intervals in comparison with originally established intervals for both MEA and PFA-100 in low platelet or hematocrit conditions. Multiple regression analysis of ASPI and both tests on the PFA-100 for combined low platelet and hematocrit conditions revealed that only PFA-100 testing should be adjusted for both thrombocytopenia and anemia. 95% reference intervals were calculated using multiple regression analysis. However, coefficients of determination of PFA-100 were poor, and some variance remained unexplained. Thus, in this pilot study using (multiple) regression analysis, we could establish reference intervals of platelet function in anemia and thrombocytopenia conditions on PFA-100 and in thrombocytopenia conditions on MEA.

  18. Paediatric reference interval and biological variation trends of thyrotropin (TSH) and free thyroxine (T4) in an Asian population.

    PubMed

    Loh, Tze Ping; Sethi, Sunil Kumar; Metz, Michael Patrick

    2015-08-01

    To describe the reference intervals and biological variation data for thyrotropin (TSH) and free thyroxine (FT4) in a mixed Asian population using an indirect sampling approach and to compare them with published reports. TSH and FT4 of children measured once or twice over a 7-year period (2008-2014) at primary-care and tertiary-care settings were extracted from the laboratory information system. After excluding outliers, age-related reference intervals were derived using the Lambda-Mu-Sigma (LMS) approach, while age-partitioned biological variation data were obtained according to recommendations by Fraser and Harris. Both TSH and FT4 were very high at birth and declined with age. Similarly within-individual and between-individual biological variations were higher for both TSH and FT4 at birth and also declined with age. Our data were broadly similar to previous studies. Significant heterogeneity in study population and methods prohibited direct numerical comparison between this and previously published studies. This study fills two important gaps in our knowledge of paediatric thyroid function by reporting the centile trends (and reference values) in a mixed Asian population, as well as providing age-partitioned biological variation data. The variation in published reference intervals highlights the difficulty in harmonising paediatric thyroid reference intervals or recommending universal clinical cut-offs. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. Establishment of reference intervals for plasma protein electrophoresis in Indo-Pacific green sea turtles, Chelonia mydas

    PubMed Central

    Flint, Mark; Matthews, Beren J.; Limpus, Colin J.; Mills, Paul C.

    2015-01-01

    Biochemical and haematological parameters are increasingly used to diagnose disease in green sea turtles. Specific clinical pathology tools, such as plasma protein electrophoresis analysis, are now being used more frequently to improve our ability to diagnose disease in the live animal. Plasma protein reference intervals were calculated from 55 clinically healthy green sea turtles using pulsed field electrophoresis to determine pre-albumin, albumin, α-, β- and γ-globulin concentrations. The estimated reference intervals were then compared with data profiles from clinically unhealthy turtles admitted to a local wildlife hospital to assess the validity of the derived intervals and identify the clinically useful plasma protein fractions. Eighty-six per cent {19 of 22 [95% confidence interval (CI) 65–97]} of clinically unhealthy turtles had values outside the derived reference intervals, including the following: total protein [six of 22 turtles or 27% (95% CI 11–50%)], pre-albumin [two of five, 40% (95% CI 5–85%)], albumin [13 of 22, 59% (95% CI 36–79%)], total albumin [13 of 22, 59% (95% CI 36–79%)], α- [10 of 22, 45% (95% CI 24–68%)], β- [two of 10, 20% (95% CI 3–56%)], γ- [one of 10, 10% (95% CI 0.3–45%)] and β–γ-globulin [one of 12, 8% (95% CI 0.2–38%)] and total globulin [five of 22, 23% (8–45%)]. Plasma protein electrophoresis shows promise as an accurate adjunct tool to identify a disease state in marine turtles. This study presents the first reference interval for plasma protein electrophoresis in the Indo-Pacific green sea turtle. PMID:27293722

  20. Normal reference intervals and the effects of time and feeding on serum bile acid concentrations in llamas.

    PubMed

    Andreasen, C B; Pearson, E G; Smith, B B; Gerros, T C; Lassen, E D

    1998-04-01

    Fifty clinically healthy llamas, 0.5-13 years of age (22 intact males, 10 neutered males, 18 females), with no biochemical evidence of liver disease or hematologic abnormalities, were selected to establish serum bile acid reference intervals. Serum samples submitted to the clinical pathology laboratory were analyzed using a colorimetric enzymatic assay to establish bile acid reference intervals. A nonparametric distribution of llama bile acid concentrations was 1-23 micromol/liter for llamas >1 year of age and 10-44 micromol/liter for llamas < or = 1 year of age. A significant difference was found between these 2 age groups. No correlation was detected between gender and bile acid concentrations. The reference intervals were 1.1-22.9 micromol/liter for llamas >1 year of age and 1.8-49.8 micromol/liter for llamas < or = 1 year of age. Additionally, a separate group of 10 healthy adult llamas (5 males, 5 females, 5-11 years of age) without biochemical or hematologic abnormalities was selected to assess the effects of feeding and time intervals on serum bile acid concentrations. These 10 llamas were provided fresh water and hay ad libitum, and serum samples were obtained via an indwelling jugular catheter hourly for 11 hours. Llamas were then kept from food overnight (12 hours), and subsequent samples were taken prior to feeding (fasting baseline time, 23 hours after trial initiation) and postprandially at 0.5, 1, 2, 4, and 8 hours. In feeding trials, there was no consistent interaction between bile acid concentrations and time, feeding, or 12-hour fasting. Prior feeding or time of day did not result in serum bile acid concentrations outside the reference interval, but concentrations from individual llamas varied within this interval over time.

  1. Reference intervals for urinary renal injury biomarkers KIM-1 and NGAL in healthy children

    PubMed Central

    McWilliam, Stephen J; Antoine, Daniel J; Sabbisetti, Venkata; Pearce, Robin E; Jorgensen, Andrea L; Lin, Yvonne; Leeder, J Steven; Bonventre, Joseph V; Smyth, Rosalind L; Pirmohamed, Munir

    2014-01-01

    Aim The aim of this study was to establish reference intervals in healthy children for two novel urinary biomarkers of acute kidney injury, kidney injury molecule-1 (KIM-1) and neutrophil gelatinase-associated lipocalin (NGAL). Materials & Methods Urinary biomarkers were determined in samples from children in the UK (n = 120) and the USA (n = 171) using both Meso Scale Discovery (MSD) and Luminex-based analytical approaches. Results 95% reference intervals for each biomarker in each cohort are presented and stratified by sex or ethnicity where necessary, and age-related variability is explored using quantile regression. We identified consistently higher NGAL concentrations in females than males (p < 0.0001), and lower KIM-1 concentrations in African–Americans than Caucasians (p = 0.02). KIM-1 demonstrated diurnal variation, with higher concentrations in the morning (p < 0.001). Conclusion This is the first report of reference intervals for KIM-1 and NGAL using two analytical methods in a healthy pediatric population in both UK and US-based populations. PMID:24661102

  2. Evaluation of an anal sac adenocarcinoma tumor in a Spitz dog

    PubMed Central

    Javanbakht, Javad; Tavassoli, Abbas; Sabbagh, Atefeh; Hassan, Mehdy Aghamohammmad; Samakkhah, Shohreh Alian; Shafiee, Radmehr; Lakzian, Ali; Ghalee, Vahideh Rahmani; Gharebagh, Sonia Shoja

    2013-01-01

    A 9-year-old emasculated male Spitz with tenesmus and constipation had a subcutaneous mass at the left ventral aspect of the anus with history of polyuria and polydipsia. A complete blood cell count, serum biochemistry panel, and urinalysis (cystocentesis sample) were evaluated. Abnormalities in the serum biochemistry panel included a mildly elevated serum cholesterol concentration (7.28 mmol/L; reference interval, 2.70–5.94 mmol/L), increased serum alkaline phosphatase activity (184 U/L; reference interval, 9–90 U/L), alanine transaminase (122 U/L; reference interval, 5–60 U/L) activity and aspartate aminotransferase (80 U/L; reference interval, 5–55 U/L) activity, severe increased total calcium concentration (16.3 mg/dL; reference interval, 8.2–12.4 mg/dL or 9.3–11.4 mg/dL), and decreased total calcium concentration (3.4 mg/dL, reference interval, 2.5–5.6mg/dL). Furthermore, testing revealed an increased intact parathyroid hormone concentration (38.6 pmol/L; reference interval, 3–17 pmol/L). On cytologic and histopathologic examinations, various types of cells were observed. Most of the cells were oval to polygonal and had elliptical or elongate nuclei and a moderate amount of pale to basophilic cytoplasm. The remaining cells had round to oval nuclei and pale to basophilic cytoplasm. Cells of both types were loosely adhered to each other and were arranged in rosette-like structures. Both neoplastic cell types had fine homogenous chromatin and either a small indistinct nucleolus or no visible nucleolus. Mild anisokaryosis and anisocytosis were observed. Histologically, the mass consists of glandular structures formed by cuboidal cells admixed with bundles of spindle cells. Based on location and histologic features, the final diagnosis was adenocarcinoma of the apocrine gland of the anal sac, which should be included as a cytologic differential diagnosis when spindle cells and typical epithelial cells are observed in masses in the region of the anal sac of dogs. PMID:23570021

  3. Reference intervals for serum osteocalcin concentrations in adult men and women from the study of health in Pomerania.

    PubMed

    Hannemann, Anke; Friedrich, Nele; Spielhagen, Christin; Rettig, Rainer; Ittermann, Till; Nauck, Matthias; Wallaschofski, Henri

    2013-03-13

    Osteocalcin (OC) is a bone-specific protein produced primarily by osteoblasts during bone formation. Besides its role in bone formation, osteocalcin may play a role in the regulation of energy metabolism and male fertility. To interpret serum OC data, reference intervals adapted to a specific laboratory method are needed. A healthy reference population was selected from the first follow-up of the Study of Health in Pomerania. Serum OC concentrations were measured with the IDS-iSYS N-Mid Osteocalcin assay on the IDS-iSYS Automated System (Immunodiagnostic Systems, Frankfurt am Main, Germany). The reference interval was defined as the central 95% range (2.5th-97.5th percentile). Age-specific reference intervals were calculated by quantile regression for 1107 men (25-79 years) and 545 premenopausal women (25-54 years). The reference interval for 498 postmenopausal women (50-79 years) was calculated irrespective of age. Median (1st-3rd quartile) serum OC concentrations were 15.4 ng/mL (12.0-19.4 ng/mL) in men, 14.4 ng/mL (11.3-18.5 ng/mL) in premenopausal women, and 18.6 ng/mL (13.6-25.6 ng/mL) in postmenopausal women. Serum OC concentrations were highest in men and premenopausal women aged 25-29 years, were stable during midlife, and rose again after 65 years of age in men and at transition to menopause in women. Serum OC concentrations were lower in women taking oral contraceptives or who were under hormone replacement therapy after menopause and in subjects with diabetes mellitus or with body mass index < 18 or > 30 kg/m2 than in subjects without these conditions. We established sex-specific adult reference intervals for the serum OC concentration measured by the IDS-iSYS N-Mid Osteocalcin assay.

  4. Age- and Gender-Specific Reference Intervals for Fasting Blood Glucose and Lipid Levels in School Children Measured With Abbott Architect c8000 Chemistry Analyzer.

    PubMed

    Tamimi, Waleed; Albanyan, Esam; Altwaijri, Yasmin; Tamim, Hani; Alhussein, Fahad

    2012-04-01

    Reference intervals for pubertal characteristics are influenced by genetic, geographic, dietary and socioeconomic factors. Therefore, the aim of this study was to establish age-specific reference intervals of glucose and lipid levels among local school children. This was cross-sectional study, conducted among Saudi school children. Fasting blood samples were collected from 2149 children, 1138 (53%) boys and 1011 (47%) girls, aged 6 to 18 years old. Samples were analyzed on the Architect c8000 Chemistry System (Abbott Diagnostics, USA) for glucose, cholesterol, triglycerides, HDL and LDL. Reference intervals were established by nonparametric methods between the 2.5th and 97.5th percentiles. Significant differences were observed between boys and girls for cholesterol and triglycerides levels in all age groups (P < 0.02). Only at age 6-7 years and at adolescents, HDL and LDL levels were found to be significant (P < 0.001). No significant differences were seen in glucose levels except at age 12 to 13 years. Saudi children have comparable serum cholesterol levels than their Western counterparts. This may reflect changing dietary habits and increasing affluence in Saudi Arabia. Increased lipid screening is anticipated, and these reference intervals will aid in the early assessment of cardiovascular and diabetes risk in Saudi pediatric populations.

  5. The establishment of tocopherol reference intervals for Hungarian adult population using a validated HPLC method.

    PubMed

    Veres, Gábor; Szpisjak, László; Bajtai, Attila; Siska, Andrea; Klivényi, Péter; Ilisz, István; Földesi, Imre; Vécsei, László; Zádori, Dénes

    2017-09-01

    Evidence suggests that decreased α-tocopherol (the most biologically active substance in the vitamin E group) level can cause neurological symptoms, most likely ataxia. The aim of the current study was to first provide reference intervals for serum tocopherols in the adult Hungarian population with appropriate sample size, recruiting healthy control subjects and neurological patients suffering from conditions without symptoms of ataxia, myopathy or cognitive deficiency. A validated HPLC method applying a diode array detector and rac-tocol as internal standard was utilized for that purpose. Furthermore, serum cholesterol levels were determined as well for data normalization. The calculated 2.5-97.5% reference intervals for α-, β/γ- and δ-tocopherols were 24.62-54.67, 0.81-3.69 and 0.29-1.07 μm, respectively, whereas the tocopherol/cholesterol ratios were 5.11-11.27, 0.14-0.72 and 0.06-0.22 μmol/mmol, respectively. The establishment of these reference intervals may improve the diagnostic accuracy of tocopherol measurements in certain neurological conditions with decreased tocopherol levels. Moreover, the current study draws special attention to the possible pitfalls in the complex process of the determination of reference intervals as well, including the selection of study population, the application of internal standard and method validation and the calculation of tocopherol/cholesterol ratios. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Hematology and serum clinical chemistry reference intervals for free-ranging Scandinavian gray wolves (Canis lupus).

    PubMed

    Thoresen, Stein I; Arnemo, Jon M; Liberg, Olof

    2009-06-01

    Scandinavian free-ranging wolves (Canis lupus) are endangered, such that laboratory data to assess their health status is increasingly important. Although wolves have been studied for decades, most biological information comes from captive animals. The objective of the present study was to establish reference intervals for 30 clinical chemical and 8 hematologic analytes in Scandinavian free-ranging wolves. All wolves were tracked and chemically immobilized from a helicopter before examination and blood sampling in the winter of 7 consecutive years (1998-2004). Seventy-nine blood samples were collected from 57 gray wolves, including 24 juveniles (24 samples), 17 adult females (25 samples), and 16 adult males (30 samples). Whole blood and serum samples were stored at refrigeration temperature for 1-3 days before hematologic analyses and for 1-5 days before serum biochemical analyses. Reference intervals were calculated as 95% confidence intervals except for juveniles where the minimum and maximum values were used. Significant differences were observed between adult and juvenile wolves for RBC parameters, alkaline phosphatase and amylase activities, and total protein, albumin, gamma-globulins, cholesterol, creatinine, calcium, chloride, magnesium, phosphate, and sodium concentrations. Compared with published reference values for captive wolves, reference intervals for free-ranging wolves reflected exercise activity associated with capture (higher creatine kinase activity, higher glucose concentration), and differences in nutritional status (higher urea concentration).

  7. Original articles published in Revista Española de Enfermedades Digestivas (1993-1998): authorship, interval between acceptance and publication, and bibliographic references.

    PubMed

    Acea Nebril, B; Figueira Moure, A; Gómez Freijoso, C

    2000-09-01

    To study changes in authorship, interval between acceptance and publication, and bibliographic references of original articles published in Revista Española de Enfermedades Digestivas (REED) between 1993 and 1998. This was a descriptive retrospective study of 359 original research articles published in REED between 1993 and 1998. The variables assessed were: number of authors (author/article index), interval between acceptance of the manuscript and publication in the journal, and degree of obsolescence of articles based on the age of the references cited (Burton-Kleber and Price indexes). The author/article index was 6.1, and increased from 5.9 in 1993 to 6.5 in 1998. The interval between acceptance and publication increased from 251 days to 436 days in this period (p < 0.0001). English was the language of publication used most commonly, followed by Spanish (10.7%). Citations to Spanish references decreased from 12.5% in 1993 to 8.7% in 1998. The half-life of articles was 7 years, and Price index was 41.5%. REED's bibliometric characteristics are similar to those of other national journals, but this study shows changes in bibliographic indicators from 1993 to 1998; increases in the number of authors per article, the interval to publication, the use of foreign references and the degree of obsolescence.

  8. Continuous age- and sex-adjusted reference intervals of urinary markers for cerebral creatine deficiency syndromes: a novel approach to the definition of reference intervals.

    PubMed

    Mørkrid, Lars; Rowe, Alexander D; Elgstoen, Katja B P; Olesen, Jess H; Ruijter, George; Hall, Patricia L; Tortorelli, Silvia; Schulze, Andreas; Kyriakopoulou, Lianna; Wamelink, Mirjam M C; van de Kamp, Jiddeke M; Salomons, Gajja S; Rinaldo, Piero

    2015-05-01

    Urinary concentrations of creatine and guanidinoacetic acid divided by creatinine are informative markers for cerebral creatine deficiency syndromes (CDSs). The renal excretion of these substances varies substantially with age and sex, challenging the sensitivity and specificity of postanalytical interpretation. Results from 155 patients with CDS and 12 507 reference individuals were contributed by 5 diagnostic laboratories. They were binned into 104 adjacent age intervals and renormalized with Box-Cox transforms (Ξ). Estimates for central tendency (μ) and dispersion (σ) of Ξ were obtained for each bin. Polynomial regression analysis was used to establish the age dependence of both μ[log(age)] and σ[log(age)]. The regression residuals were then calculated as z-scores = {Ξ - μ[log(age)]}/σ[log(age)]. The process was iterated until all z-scores outside Tukey fences ±3.372 were identified and removed. Continuous percentile charts were then calculated and plotted by retransformation. Statistically significant and biologically relevant subgroups of z-scores were identified. Significantly higher marker values were seen in females than males, necessitating separate reference intervals in both adolescents and adults. Comparison between our reconstructed reference percentiles and current standard age-matched reference intervals highlights an underlying risk of false-positive and false-negative events at certain ages. Disease markers depending strongly on covariates such as age and sex require large numbers of reference individuals to establish peripheral percentiles with sufficient precision. This is feasible only through collaborative data sharing and the use of appropriate statistical methods. Broad application of this approach can be implemented through freely available Web-based software. © 2015 American Association for Clinical Chemistry.

  9. Pragmatic and evidence-based approach to paediatric cerebrospinal fluid reference limits for white cell count and concentrations of total protein and glucose.

    PubMed

    Josman, Nicky; Tee, Nancy W S; Maiwald, Matthias; Loo, Liat Hui; Ho, Clement K M

    2018-06-15

    It is often impractical for each laboratory to establish its own paediatric reference intervals. This is particularly true for specimen types collected using invasive procedures, for example, cerebrospinal fluid (CSF). Published CSF reference intervals for white cell count, and concentrations of total protein and glucose were reviewed by stakeholders in a paediatric hospital. Consensus reference intervals for the three CSF parameters were then subjected to verification using guidelines from the Clinical Laboratory Standards Institute and residual CSF specimens. Consensus paediatric reference intervals adapted from published studies with minor modifications were locally verified as follows. White cell count (x10 6 cells/L): 0-20 (<1 month); 0-10 (1-2 months); 0-5 (>2 months). Total protein (g/L): 0.3-1.2 (<1 month); 0.2-0.6 (1-3 months); 0.1-0.4 (>3 months). Glucose (mmol/L): 2.0-5.6 (<6 months); 2.4-4.3 (6 months or older). © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. Reference intervals for serum biochemistries of molting Pacific Black Brant (Branta bernicla nigricans) in Northern Alaska, USA

    USGS Publications Warehouse

    Franson, J. Christian; Flint, Paul L.; Schmutz, Joel A.

    2017-01-01

    We determined reference intervals for nine serum biochemistries in samples from 329 molting, after-hatch-year, Pacific Black Brant (Branta bernicla nigricans) in Alaska, US. Cholesterol and nonesterified fatty acids differed by sex, but no other differences were noted.

  11. Comparing age-wise reference intervals for serum creatinine concentration in a "Reality check" of the recommended cut-off.

    PubMed

    Verma, Mascha; Khadapkar, Rashmi; Sahu, Priyadarshi Soumyaranjan; Das, Bibhu Ranjan

    2006-09-01

    An increase in the communication within the healthcare services, both nationally and internationally, has strengthened the need for harmonization of measurements and reference intervals in laboratory medicine. In the present report, the calculated reference interval for serum creatinine (sCr) levels of healthy normal individuals (n=1121) in different sex and age groups are compared with the established interval. The calculated reference interval for sCr level was 0.4-1.3 mg/dL and 0.6 to 1.3 mg/dL in the age groups of 21-40 and 41-60 years respectively. The difference between the mean sCr values in total males and total females (age range 21-60 years) was statistically significant (p<0.0001); When male and female subjects were analyzed age-group wise, the data showed a significant difference in mean sCr values (p<0.0001) in three age groups (21-30, 31-40 and 41-50 years) however, in older age group (51-60 years), the difference was non-significant (p=0.07). The reference ranges were 0.7-1.3 and 0.4-1.0 mg/dL for males and females respectively where the lower limit was 0.1-0.2 units less than that of standard limits. An increase in the mean value of sCr was observed particularly in females with an increase in age. Hence it is of interest to validate an age specific reference ranges for sCr in our population.

  12. Patient, surgeon, and hospital disparities associated with benign hysterectomy approach and perioperative complications.

    PubMed

    Mehta, Ambar; Xu, Tim; Hutfless, Susan; Makary, Martin A; Sinno, Abdulrahman K; Tanner, Edward J; Stone, Rebecca L; Wang, Karen; Fader, Amanda N

    2017-05-01

    Hysterectomy is among the most common major surgical procedures performed in women. Approximately 450,000 hysterectomy procedures are performed each year in the United States for benign indications. However, little is known regarding contemporary US hysterectomy trends for women with benign disease with respect to operative technique and perioperative complications, and the association between these 2 factors with patient, surgeon, and hospital characteristics. We sought to describe contemporary hysterectomy trends and explore associations between patient, surgeon, and hospital characteristics with surgical approach and perioperative complications. Hysterectomies performed for benign indications by general gynecologists from July 2012 through September 2014 were analyzed in the all-payer Maryland Health Services Cost Review Commission database. We excluded hysterectomies performed by gynecologic oncologists, reproductive endocrinologists, and female pelvic medicine and reconstructive surgeons. We included both open hysterectomies and those performed by minimally invasive surgery, which included vaginal hysterectomies. Perioperative complications were defined using the Agency for Healthcare Research and Quality patient safety indicators. Surgeon hysterectomy volume during the 2-year study period was analyzed (0-5 cases annually = very low, 6-10 = low, 11-20 = medium, and ≥21 = high). We utilized logistic regression and negative binomial regression to identify patient, surgeon, and hospital characteristics associated with minimally invasive surgery utilization and perioperative complications, respectively. A total of 5660 hospitalizations were identified during the study period. Most patients (61.5%) had an open hysterectomy; 38.5% underwent a minimally invasive surgery procedure (25.1% robotic, 46.6% laparoscopic, 28.3% vaginal). Most surgeons (68.2%) were very low- or low-volume surgeons. Factors associated with a lower likelihood of undergoing minimally invasive surgery included older patient age (reference 45-64 years; 20-44 years: adjusted odds ratio, 1.16; 95% confidence interval, 1.05-1.28), black race (reference white; adjusted odds ratio, 0.70; 95% confidence interval, 0.63-0.78), Hispanic ethnicity (adjusted odds ratio, 0.62; 95% confidence interval, 0.48-0.80), smaller hospital (reference large; small: adjusted odds ratio, 0.26; 95% confidence interval, 0.15-0.45; medium: adjusted odds ratio, 0.87; 95% confidence interval, 0.79-0.96), medium hospital hysterectomy volume (reference ≥200 hysterectomies; 100-200: adjusted odds ratio, 0.78; 95% confidence interval, 0.71-0.87), and medium vs high surgeon volume (reference high; medium: adjusted odds ratio, 0.87; 95% confidence interval, 0.78-0.97). Complications occurred in 25.8% of open and 8.2% of minimally invasive hysterectomies (P < .0001). Minimally invasive hysterectomy (adjusted odds ratio, 0.22; 95% confidence interval, 0.17-0.27) and large hysterectomy volume hospitals (reference ≥200 hysterectomies; 1-100: adjusted odds ratio, 2.26; 95% confidence interval, 1.60-3.20; 101-200: adjusted odds ratio, 1.63; 95% confidence interval, 1.23-2.16) were associated with fewer complications, while patient payer, including Medicare (reference private; adjusted odds ratio, 1.86; 95% confidence interval, 1.33-2.61), Medicaid (adjusted odds ratio, 1.63; 95% confidence interval, 1.30-2.04), and self-pay status (adjusted odds ratio, 2.41; 95% confidence interval, 1.40-4.12), and very-low and low surgeon hysterectomy volume (reference ≥21 cases; 1-5 cases: adjusted odds ratio, 1.73; 95% confidence interval, 1.22-2.47; 6-10 cases: adjusted odds ratio, 1.60; 95% confidence interval, 1.11-2.23) were associated with perioperative complications. Use of minimally invasive hysterectomy for benign indications remains variable, with most patients undergoing open, more morbid procedures. Older and black patients and smaller hospitals are associated with open hysterectomy. Patient race and payer status, hysterectomy approach, and surgeon volume were associated with perioperative complications. Hysterectomies performed for benign indications by high-volume surgeons or by minimally invasive techniques may represent an opportunity to reduce preventable harm. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Perspective: The Case for an Evidence-Based Reference Interval for Serum Magnesium: The Time Has Come.

    PubMed

    Costello, Rebecca B; Elin, Ronald J; Rosanoff, Andrea; Wallace, Taylor C; Guerrero-Romero, Fernando; Hruby, Adela; Lutsey, Pamela L; Nielsen, Forrest H; Rodriguez-Moran, Martha; Song, Yiqing; Van Horn, Linda V

    2016-11-01

    The 2015 Dietary Guidelines Advisory Committee indicated that magnesium was a shortfall nutrient that was underconsumed relative to the Estimated Average Requirement (EAR) for many Americans. Approximately 50% of Americans consume less than the EAR for magnesium, and some age groups consume substantially less. A growing body of literature from animal, epidemiologic, and clinical studies has demonstrated a varied pathologic role for magnesium deficiency that includes electrolyte, neurologic, musculoskeletal, and inflammatory disorders; osteoporosis; hypertension; cardiovascular diseases; metabolic syndrome; and diabetes. Studies have also demonstrated that magnesium deficiency is associated with several chronic diseases and that a reduced risk of these diseases is observed with higher magnesium intake or supplementation. Subclinical magnesium deficiency can exist despite the presentation of a normal status as defined within the current serum magnesium reference interval of 0.75-0.95 mmol/L. This reference interval was derived from data from NHANES I (1974), which was based on the distribution of serum magnesium in a normal population rather than clinical outcomes. What is needed is an evidenced-based serum magnesium reference interval that reflects optimal health and the current food environment and population. We present herein data from an array of scientific studies to support the perspective that subclinical deficiencies in magnesium exist, that they contribute to several chronic diseases, and that adopting a revised serum magnesium reference interval would improve clinical care and public health. © 2016 American Society for Nutrition.

  14. Perspective: The Case for an Evidence-Based Reference Interval for Serum Magnesium: The Time Has Come12345

    PubMed Central

    Elin, Ronald J; Rosanoff, Andrea; Lutsey, Pamela L; Nielsen, Forrest H; Rodriguez-Moran, Martha

    2016-01-01

    The 2015 Dietary Guidelines Advisory Committee indicated that magnesium was a shortfall nutrient that was underconsumed relative to the Estimated Average Requirement (EAR) for many Americans. Approximately 50% of Americans consume less than the EAR for magnesium, and some age groups consume substantially less. A growing body of literature from animal, epidemiologic, and clinical studies has demonstrated a varied pathologic role for magnesium deficiency that includes electrolyte, neurologic, musculoskeletal, and inflammatory disorders; osteoporosis; hypertension; cardiovascular diseases; metabolic syndrome; and diabetes. Studies have also demonstrated that magnesium deficiency is associated with several chronic diseases and that a reduced risk of these diseases is observed with higher magnesium intake or supplementation. Subclinical magnesium deficiency can exist despite the presentation of a normal status as defined within the current serum magnesium reference interval of 0.75–0.95 mmol/L. This reference interval was derived from data from NHANES I (1974), which was based on the distribution of serum magnesium in a normal population rather than clinical outcomes. What is needed is an evidenced-based serum magnesium reference interval that reflects optimal health and the current food environment and population. We present herein data from an array of scientific studies to support the perspective that subclinical deficiencies in magnesium exist, that they contribute to several chronic diseases, and that adopting a revised serum magnesium reference interval would improve clinical care and public health. PMID:28140318

  15. Determination of hematology and plasma chemistry reference intervals for 3 populations of captive Atlantic sturgeon (Acipenser oxyrinchus oxyrinchus).

    PubMed

    Matsche, Mark A; Arnold, Jill; Jenkins, Erin; Townsend, Howard; Rosemary, Kevin

    2014-09-01

    The imperiled status of Atlantic sturgeon (Acipenser oxyrinchus oxyrinchus), a large, long-lived, anadromous fish found along the Atlantic coast of North America, has prompted efforts at captive propagation for research and stock enhancement. The purpose of this study was to establish hematology and plasma chemistry reference intervals of captive Atlantic sturgeon maintained under different culture conditions. Blood specimens were collected from a total of 119 fish at 3 hatcheries: Lamar, PA (n = 36, ages 10-14 years); Chalk Point, MD (n = 40, siblings of Lamar); and Horn Point, Cambridge, MD (n = 43, mixed population from Chesapeake Bay). Reference intervals (using robust techniques), median, mean, and standard deviations were determined for WBC, RBC, thrombocytes, PCV, HGB, MCV, MCH, MCHC, and absolute counts for lymphocytes (L), neutrophils (N), monocytes, and eosinophils. Chemistry analytes included concentrations of total proteins, albumin, glucose, urea, calcium, phosphate, sodium, potassium, chloride, and globulins, AST, CK, and LDH activities, and osmolality. Mean concentrations of total proteins, albumin, and glucose were at or below the analytic range. Statistical comparisons showed significant differences among hatcheries for each remaining plasma chemistry analyte and for PCV, RBC, MCHC, MCH, eosinophil and monocyte counts, and N:L ratio throughout all 3 groups. Therefore, reference intervals were calculated separately for each population. Reference intervals for fish maintained under differing conditions should be established per population. © 2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.

  16. Establishment of reference intervals for serum thyroid-stimulating hormone, free and total thyroxine, and free and total triiodothyronine for the Beckman Coulter DxI-800 analyzers by indirect method using data obtained from Chinese population in Zhejiang Province, China.

    PubMed

    Wang, Yan; Zhang, Yu-Xia; Zhou, Yong-Lie; Xia, Jun

    2017-07-01

    In order to establish suitable reference intervals of thyroid-stimulating hormone (TSH), free (unbound) T4 (FT4), free triiodothyronine (FT3), total thyroxine (T4), and total triiodothyronine (T3) for the patients collected in Zhejiang, China, an indirect method was developed using the data from the people presented for routine health check-up. Fifteen thousand nine hundred and fifty-six person's results were reviewed. Box-Cox or Case Rank was used to transform the data to normal distribution. Tukey and Box-Plot methods were used to exclude the outliers. Nonparametric method was used to establish the reference intervals following the EP28-A3c guideline. Pearson correlation was used to evaluate the correlation between hormone levels and age, while Mann-Whitney U test was employed for quantification of concentration differences on the people who are younger and older than 50 years old. Reference intervals were 0.66-4.95 mIU/L (TSH), 8.97-14.71 pmol/L (FT4), 3.75-5.81 pmol/L (FT3), 73.45-138.93 nmol/L (total T4), and 1.24-2.18 nmol/L (total T3) in male; conversely, reference intervals for female were 0.72-5.84 mIU/L (TSH), 8.62-14.35 pmol/L (FT4), 3.59-5.56 pmol/L (FT3), 73.45-138.93 nmol/L (total T4), and 1.20-2.10 nmol/L (total T3). FT4, FT3, and total T3 levels in male and FT4 level in female had an inverse correlation with age. Total T4 and TSH levels in female were directly correlated. Significant differences in these hormones were also found between younger and older than 50 years old except FT3 in female. Indirect method can be applied for establishment of reference intervals for TSH, FT4, FT3, total T4, and total T3. The reference intervals are narrower than those previously established. Age factor should also be considered. © 2016 Wiley Periodicals, Inc.

  17. Linear time-dependent reference intervals where there is measurement error in the time variable-a parametric approach.

    PubMed

    Gillard, Jonathan

    2015-12-01

    This article re-examines parametric methods for the calculation of time specific reference intervals where there is measurement error present in the time covariate. Previous published work has commonly been based on the standard ordinary least squares approach, weighted where appropriate. In fact, this is an incorrect method when there are measurement errors present, and in this article, we show that the use of this approach may, in certain cases, lead to referral patterns that may vary with different values of the covariate. Thus, it would not be the case that all patients are treated equally; some subjects would be more likely to be referred than others, hence violating the principle of equal treatment required by the International Federation for Clinical Chemistry. We show, by using measurement error models, that reference intervals are produced that satisfy the requirement for equal treatment for all subjects. © The Author(s) 2011.

  18. Reference intervals and longitudinal changes in copeptin and MR-proADM concentrations during pregnancy.

    PubMed

    Joosen, Annemiek M C P; van der Linden, Ivon J M; Schrauwen, Lianne; Theeuwes, Alisia; de Groot, Monique J M; Ermens, Antonius A M

    2017-11-27

    Vasopressin and adrenomedullin and their stable by-products copeptin and midregional part of proadrenomedullin (MR-proADM) are promising biomarkers for the development of preeclampsia. However, clinical use is hampered by the lack of trimester-specific reference intervals. We therefore estimated reference intervals for copeptin and MR-proADM in disease-free Dutch women throughout pregnancy. Apparently healthy low risk pregnant women were recruited. Exclusion criteria included current or past history of endocrine disease, multiple pregnancy, use of medication known to influence thyroid function and current pregnancy as a result of hormonal stimulation. Women who miscarried, developed hyperemesis gravidarum, hypertension, pre-eclampsia, hemolysis elevated liver enzymes and low platelets, diabetes or other disease, delivered prematurely or had a small for gestational age neonate were excluded from analyses. Blood samples were collected at 9-13 weeks (n=98), 27-29 weeks (n=94) and 36-39 weeks (n=91) of gestation and at 4-13 weeks post-partum (PP) (n=89). Sixty-two women had complete data during pregnancy and PP. All analyses were performed on a Kryptor compact plus. Copeptin increases during pregnancy, but 97.5th percentiles remain below the non-pregnant upper reference limit (URL) provided by the manufacturer. MR-proADM concentrations increase as well during pregnancy. In trimesters 2 and 3 the 97.5th percentiles are over three times the non-pregnant URL provided by the manufacturer. Trimester- and assay-specific reference intervals for copeptin and MR-proADM should be used. In addition, consecutive measurements and the time frame between measurements should be considered as the differences seen with or in advance of preeclampsia can be expected to be relatively small compared to the reference intervals.

  19. The biomedical piglet: establishing reference intervals for haematology and clinical chemistry parameters of two age groups with and without iron supplementation.

    PubMed

    Ventrella, Domenico; Dondi, Francesco; Barone, Francesca; Serafini, Federica; Elmi, Alberto; Giunti, Massimo; Romagnoli, Noemi; Forni, Monica; Bacci, Maria L

    2017-01-17

    The similarities between swine and humans in physiological and genomic patterns, and the great correlation in size and anatomy, make pigs extremely useful in preclinical studies. New-born piglets can represent a model for congenital and genetic diseases in new-born children. It is known that piglets may have significant differences in clinicopathological results compared to adult pigs. Therefore, adult laboratory reference intervals cannot be applied to piglets. The aim of this study was to compare haematological and chemical variables in piglets of two ages and determinate age-related reference intervals for commercial hybrid young pigs. Blood samples were collected under general anaesthesia from 130 animals divided into five- (P5) and 30- (P30) day-old piglets. Only P30 animals were treated with parenteral iron after birth. Samples were analysed using automated haematology (ADVIA 2120) and chemistry analysers, and age-related reference intervals were calculated. Significant higher values of RBC, Hb and HCT were observed in P30 animals when compared to P5, with an opposite trend for MCV. These results were associated with a reduction of the RBC regeneration process and the thrombopoietic response. The TSAT and TIBC were significantly higher in P30 compared to P5; however, piglets remained iron deficient compared to adult reference intervals reported previously. In conclusion, this paper emphasises the high variability occurring in clinicopathological variables between new-born and 30-day-old pigs, and between piglets and adult pigs. This study provides valuable reference data for piglets at precise ages and could be used in the future as historical control improving the Reduction in animal experiments, as suggested by the 3Rs principle.

  20. Multicentre physiological reference intervals for serum concentrations of immunoglobulins A, G and M, complement C3c and C4 measured with Tina-Quant reagents systems.

    PubMed

    Fuentes-Arderiu, Xavier; Alonso-Gregorio, Eduardo; Alvarez-Funes, Virtudes; Ambrós-Marigómez, Carmen; Coca-Fábregas, Lluís; Cruz-Placer, Marta; Díaz-Fernández, Julián; Pinel-Julián, María Pilar; Gutiérrez-Cecchini, Beatriz; Herrero-Bernal, Pilar; Sempere-Alcocer, Marcos; García-Caballero, Francisca; Del Mar Larrea-Ortiz-Quintana, María; La-Torre-Marcellán, Pedro; Del Señor López-Vélez, María; Mar-Medina, Carmen; Martín-Oncina, Javier; Rodríguez-Hernández, María Victoria; Romero-Sotomayor, María Victoria; Serrano-López, Cándido; Sicilia-Enríquez-de-Salamanca, Adolfo; Velasco-Romero, Ana María; Juvé-Cuxart, Santiago

    2007-01-01

    Clinical laboratories seeking accreditation for compliance with ISO 15189:2003 need to demonstrate that the physiological reference intervals communicated to all users of the laboratory service are appropriate for the patient population served and for the measurement systems used. In the case of immunological quantities, few articles have been published in peer-reviewed journals. A total of 21 clinical laboratories in different regions of Spain collaborated in identifying reference individuals and determining adult reference intervals for some immunological quantities measured using RD/Hitachi Modular Analytics analysers and Tina-Quant reagent systems. These immunological quantities are the mass concentrations of immunoglobulin A, immunoglobulin G, immunoglobulin M, complement C3c and complement C4 in serum. All the logistic work was carried out in co-operation with the supplier of the reagents and analysers (Roche Diagnostics España, S.L., Sant Cugat del Vallès, Catalonia, Spain). From the set of reference values obtained by each laboratory, multicentre reference limits were estimated non-parametrically. The reference intervals estimated in this study for concentrations of serum components under consideration are: complement C3c, 0.62-1.64 g/L for women and men; complement C4, 0.14-0.72 g/L for women and men; immunoglobulin A, 0.89-4.80 g/L for women and men; immunoglobulin G, 6.5-14.3 g/L for women and men; and immunoglobulin M, 0.48-3.38 g/L for women and 0.41-2.46 g/L for men.

  1. Acute phase proteins in healthy goats: establishment of reference intervals.

    PubMed

    Heller, Meera C; Johns, Jennifer L

    2015-03-01

    Acute inflammatory processes can trigger increased production of acute phase proteins (APPs) that can be useful biomarkers of inflammation. APPs are diverse and include proteins involved in coagulation, opsonization, iron regulation, and limitation of tissue injury. Haptoglobin, serum amyloid A, and alpha-1 acid glycoprotein have been proposed as useful APPs in goats. APPs can differ markedly by species, therefore species-specific reference intervals and studies are necessary. The objective of this study was to determine species-specific reference intervals for 4 APPs in goats. Haptoglobin, serum amyloid A, lipopolysaccharide binding protein, and alpha-1 acid glycoprotein were measured in in 54 clinically normal adult goats. APPs were measured using goat-specific commercial enzyme-linked immunosorbent assay kits. Results were analyzed by 1-way analysis of variance to compare sexes and breeding status. Reference Value Advisor was used to calculate reference limits according to the IFCC-CLSI guidelines. Only 1 APP was found to vary in healthy animals; serum haptoglobin was increased in lactating animals and decreased in pregnant does in their second trimester when compared with open, nonlactating does. No sex-based differences were seen for any of the APPs measured. We report normal reference intervals for 4 serum APPs that may be useful as disease markers. Haptoglobin should be interpreted with caution in animals with unknown pregnancy status. Further studies are needed to determine whether these APPs are useful biomarkers in goat disease states. © 2015 The Author(s).

  2. Mining of hospital laboratory information systems: a model study defining age- and gender-specific reference intervals and trajectories for plasma creatinine in a pediatric population.

    PubMed

    Søeby, Karen; Jensen, Peter Bjødstrup; Werge, Thomas; Sørensen, Steen

    2015-09-01

    The knowledge of physiological fluctuation and variation of even commonly used biochemical quantities in extreme age groups and during development is sparse. This challenges the clinical interpretation and utility of laboratory tests in these age groups. To explore the utility of hospital laboratory data as a source of information, we analyzed enzymatic plasma creatinine as a model analyte in two large pediatric hospital samples. Plasma creatinine measurements from 9700 children aged 0-18 years were obtained from hospital laboratory databases and partitioned into high-resolution gender- and age-groups. Normal probability plots were used to deduce parameters of the normal distributions from healthy creatinine values in the mixed hospital datasets. Furthermore, temporal trajectories were generated from repeated measurements to examine developmental patterns in periods of changing creatinine levels. Creatinine shows great age dependence from birth throughout childhood. We computed and replicated 95% reference intervals in narrow gender and age bins and showed them to be comparable to those determined in healthy population studies. We identified pronounced transitions in creatinine levels at different time points after birth and around the early teens, which challenges the establishment and usefulness of reference intervals in those age groups. The study documents that hospital laboratory data may inform on the developmental aspects of creatinine, on periods with pronounced heterogeneity and valid reference intervals. Furthermore, part of the heterogeneity in creatinine distribution is likely due to differences in biological and chronological age of children and should be considered when using age-specific reference intervals.

  3. Memory systems in the rat: effects of reward probability, context, and congruency between working and reference memory.

    PubMed

    Roberts, William A; Guitar, Nicole A; Marsh, Heidi L; MacDonald, Hayden

    2016-05-01

    The interaction of working and reference memory was studied in rats on an eight-arm radial maze. In two experiments, rats were trained to perform working memory and reference memory tasks. On working memory trials, they were allowed to enter four randomly chosen arms for reward in a study phase and then had to choose the unentered arms for reward in a test phase. On reference memory trials, they had to learn to visit the same four arms on the maze on every trial for reward. Retention was tested on working memory trials in which the interval between the study and test phase was 15 s, 15 min, or 30 min. At each retention interval, tests were performed in which the correct WM arms were either congruent or incongruent with the correct RM arms. Both experiments showed that congruency interacted with retention interval, yielding more forgetting at 30 min on incongruent trials than on congruent trials. The effect of reference memory strength on the congruency effect was examined in Experiment 1, and the effect of associating different contexts with working and reference memory on the congruency effect was studied in Experiment 2.

  4. Canine and feline hematology reference values for the ADVIA 120 hematology system.

    PubMed

    Moritz, Andreas; Fickenscher, Yvonne; Meyer, Karin; Failing, Klaus; Weiss, Douglas J

    2004-01-01

    The ADVIA 120 is a laser-based hematology analyzer with software applications for animal species. Accurate reference values would be useful for the assessment of new hematologic parameters and for interlaboratory comparisons. The goal of this study was to establish reference intervals for CBC results and new parameters for RBC morphology, reticulocytes, and platelets in healthy dogs and cats using the ADVIA 120 hematology system. The ADVIA 120, with multispecies software (version 1.107-MS), was used to analyze whole blood samples from clinically healthy dogs (n=46) and cats (n=61). Data distribution was determined and reference intervals were calculated as 2.5 to 97.5 percentiles and 25 to 75 percentiles. Most data showed Gaussian or log-normal distribution. The numbers of RBCs falling outside the normocytic-normochromic range were slightly higher in cats than in dogs. Both dogs and cats had reticulocytes with low, medium, and high absorbance. Mean numbers of large platelets and platelet clumps were higher in cats compared with dogs. Reference intervals obtained on the ADVIA 120 provide valuable baseline information for assessing new hematologic parameters and for interlaboratory comparisons. Differences compared with previously published reference values can be attributed largely to differences in methodology.

  5. Serum ARCHITECT PIVKA-II reference interval in healthy Chinese adults: Sub-analysis from a prospective multicenter study.

    PubMed

    Yan, Cunling; Hu, Jian; Yang, Jia; Chen, Zhaoyun; Li, Huijun; Wei, Lianhua; Zhang, Wei; Xing, Hao; Sang, Guoyao; Wang, Xiaoqin; Han, Ruilin; Liu, Ping; Li, Zhihui; Li, Zhiyan; Huang, Ying; Jiang, Li; Li, Shunjun; Dai, Shuyang; Wang, Nianyue; Yang, Yongfeng; Ma, Li; Soh, Andrew; Beshiri, Agim; Shen, Feng; Yang, Tian; Fan, Zhuping; Zheng, Yijie; Chen, Wei

    2018-04-01

    Protein induced by vitamin K absence or antagonist-II (PIVKA-II) has been widely used as a biomarker for liver cancer diagnosis in Japan for decades. However, the reference intervals for serum ARCHITECT PIVKA-II have not been established in the Chinese population. Thus, this study aimed to measure serum PIVKA-II levels in healthy Chinese subjects. This is a sub-analysis from the prospective, cross-sectional and multicenter study (ClinicalTrials.gov Identifier: NCT03047603). A total of 892 healthy participants (777 Han and 115 Uygur) with complete health checkup results were recruited from 7 regional centers in China. Serum PIVKA-II level was measured by ARCHITECT immunoassay. All 95% reference ranges were estimated by nonparametric method. The distribution of PIVKA-II values showed significant difference with ethnicity and sex, but not age. The 95% reference range of PIVKA-II was 13.62-40.38 mAU/ml in Han Chinese subjects and 15.16-53.74 mAU/ml in Uygur subjects. PIVKA-II level was significantly higher in males than in females (P < 0.001). The 95% reference range of PIVKA-II was 15.39-42.01 mAU/ml in Han males while 11.96-39.13 mAU/ml in Han females. The reference interval of serum PIVKA-II on the Architect platform was established in healthy Chinese adults. This will be valuable for future clinical and laboratory studies performed using the Architect analyzer. Different ethnic backgrounds and analytical methods underline the need for redefining the reference interval of analytes such as PIVKA-II, in central laboratories in different countries. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  6. [Reference interval in preliminary investigation of maternal thyroid function during pregnancy in Shenzhen China].

    PubMed

    Yu, Lian; Yue, Huakui; Lin, Haoyun; Wu, Wenyuan

    2014-11-04

    To explore the thyroid function distribution of different trimesters among normal pregnant women and establish the reference interval for maternal thyroid function during pregnancy in Shenzhen, China. A prospective study was conducted for healthy pregnant women in first trimester (n = 334), second trimester (n = 272), third trimester (n = 271) and non-pregnant controls (n = 77) from December 2012 to June 2013 at our hospital. Free triiodothyronine (FT3), free thyroxine (FT4), thyroid stimulating hormone (TSH), triiodothyronine (TT3) and thyroxine (T4) of four groups were measured and analyzed. And the reference intervals for different trimesters were established. TSH declined in the first trimester and then rose in the second trimester. The reference ranges of TSH for early, middle and late pregnancy were 0.08-4.39, 0.41-4.16 and 0.30-5.46 mIU/L respectively. FT4 and healthy control groups showed no significant difference in the first trimester. But it declined in the second trimester. The reference ranges of FT4 for early, middle and late pregnancy were 7.74-14.58, 6.81-12.00 and 6.36-10.99 pmol/L respectively. FT3 rose slightly in the first trimester and then gradually decreased. The reference ranges of FT3 for early, middle and late pregnancy were 3.59-5.59, 3.34-4.91 and 3.09-4.58 pmol/L respectively. As compared with healthy control women in Shenzhen, thyroid function indicators of pregnant women show statistically significant differences. And the establishment of indicators of women's thyroid function reference intervals for different trimesters has important clinical significance in Shenzhen.

  7. Age-related changes in hematology and plasma chemistry values of hybrid striped bass (Morone chrysops X Morone saxatilis).

    PubMed

    Hrubec, Terry C.; Smith, Stephen A.; Robertson, John L.

    2001-01-01

    Hybrid striped bass (Morone chrysops X Morone saxatilis ) are an important aquaculture species yet there are few diagnostic tools available to assess their health. Hematology and clinical chemistry analyses are not used extensively in fish medicine due to the lack of reference intervals for various fish species, and because factors such as age can affect blood values. There is little published information regarding age-related changes in blood values of juvenile fish. It is important to evaluate juvenile fish, as this is the time they are raised in aquaculture settings. Determining age-related changes in the blood values of fishes would further develop clinical pathology as a diagnostic tool, enhancing both fish medicine and the aquaculture industry. The results of standard hematology and clinical chemistry analysis were evaluated in juvenile hybrid striped bass at 4, 6, 9, 15, and 19 months of age. Values for PCV and RBC indices were significantly lower, and plasma protein concentration was significantly higher in younger fish. Total WBC and lymphocyte counts were significantly higher in fish at 6 and 9 months of age, while neutrophil and monocyte counts were higher at 6, 9, and 15 months. Eosinophil counts were significantly higher in 9-month-old fish. The majority of hematologic values fell within previously established reference intervals, indicating that only slight modification to the intervals is necessary for evaluating hematologic results of hybrid striped bass at different ages. The following analytes deviated sufficiently from adult reference intervals to warrant separate reference values: plasma protein concentration at 4 months, WBC and lymphocyte counts at 15 and 19 months, and thrombocyte-like-cells at 9 months of age. Values for most biochemical analytes were significantly different among age groups except for creatinine and potassium concentrations. Comparisons with reference intervals were not made for biochemical analytes, because established reference intervals were not available. Age-related changes in hematologic and biochemical values of striped bass were similar to those reported for rainbow trout and mammals.

  8. Hematology and plasma chemistry reference intervals for cultured shortnose sturgeon (Acipenser brevirostrum).

    PubMed

    Knowles, Susan; Hrubec, Terry C; Smith, Stephen A; Bakal, Robert S

    2006-12-01

    The shortnose sturgeon, Acipenser brevirostrum, is an imperiled species distributed along the Atlantic coast of North America. Interest in replenishing wild stocks with hatchery-reared fish has created a need for accurate hematologic and biochemical reference intervals to evaluate the health of both fish raised in aquaculture systems and fish in the wild. The objective of this study was to generate hematologic and biochemistry reference intervals for healthy shortnose sturgeon. Blood samples were collected in heparinized tubes from 77 shortnose sturgeon raised in flow-through aquaculture systems. Whole blood and plasma samples were analyzed for hematologic and biochemical variables using standard techniques. Reference intervals were calculated as the central 95% (percentile) of data. Hematologic reference intervals (n = 46) were as follows: PCV 26-46%, hemoglobin 5.7-8.7 g/dL, MCV 307-520 fL, MCH 65.9-107.1 pg, MCHC 15-30 g/dL, plasma proteins (refractometry) 2.8-6.0 g/dL, RBC count 0.65-1.09 x 10(6)/microL, total WBC count 28,376-90,789/microL, small lymphocytes 9063-56,656/microL, large lymphocytes 2122-10,435/microL, neutrophils 3758-33,592/microL, monocytes 0-7137/microL, eosinophils 0-1544/microL, thrombocyte-like cells 6863-23,046/microL, thrombocytes 32,205-122,179/microL, and neutrophil:lymphocyte ratio 0.068-1.026. Plasma chemistry reference intervals (n = 77) were as follows: total protein 2.7-5.3 g/dL, albumin 0.8-1.7 g/dL, globulins 1.8-3.7 mg/dL, creatinine 0-1.4 mg/dL, total bilirubin 0-0.1 mg/dL, alkaline phosphatase 47-497 U/L, aspartate aminotransferase 90-311 U/L, sodium 124-141 mmol/L, potassium 2.9-3.7 mmol/L, chloride 106-121 mmol/L, calcium 6.6-12.1 mg/dL, magnesium 1.6-2.3 mg/dL, phosphorus 5.1-8.1 mg/dL, glucose 37-74 mg/dL, cholesterol 42-133 mg/dL, and osmolality 232-289 mOsm/kg. Reference values reported here will be useful for the early detection, identification, and monitoring of disease and sublethal conditions in cultured shortnose sturgeon.

  9. Trimester specific reference intervals for thyroid function tests in normal Indian pregnant women.

    PubMed

    Sekhri, Tarun; Juhi, Juhi Agarwal; Wilfred, Reena; Kanwar, Ratnesh S; Sethi, Jyoti; Bhadra, Kuntal; Nair, Sirimavo; Singh, Satveer

    2016-01-01

    Accurate assessment of thyroid function during pregnancy is critical, for initiation of thyroid hormone therapy, as well as for adjustment of thyroid hormone dose in hypothyroid cases. We evaluated pregnant women who had no past history of thyroid disorders and studied their thyroid function in each trimester. 86 normal pregnant women in the first trimester of pregnancy were selected for setting reference intervals. All were healthy, euthyroid and negative for thyroid peroxidase antibody (TPOAb). These women were serially followed throughout pregnancy. 124 normal nonpregnant subjects were selected for comparison. Thyrotropin (TSH), free thyroxine (FT4), free triiodothyronine (FT3) and anti-TPO were measured using Roche Elecsys 1010 analyzer. Urinary iodine content was determined by simple microplate method. The 2.5th and 97.5th percentiles were calculated as the reference intervals for thyroid hormone levels during each trimester. SPSS (version 14.0, SPSS Inc., Chicago, IL, USA) was used for data processing and analysis. The reference intervals for the first, second and third trimesters for the following parameters: TSH 0.09-6.65, 0.51-6.66, 0.91-4.86 µIU/mL, FT4 9.81-18.53, 8.52-19.43, 7.39-18.28 pM/L and FT3 3.1-6.35, 2.39-5.12, 2.57-5.68 pM/L respectively. Thyroid hormone concentrations significantly differed during pregnancy at different stages of gestation. The pregnant women in the study had median urinary iodine concentration of 150-200 µg/l during each trimester. The trimester-specific reference intervals for thyroid tests during pregnancy have been established for pregnant Indian women serially followed during pregnancy using 2.5th and 97.5th percentiles.

  10. Dried blood spot testing for seven steroids using liquid chromatography-tandem mass spectrometry with reference interval determination in the Korean population.

    PubMed

    Kim, Borahm; Lee, Mi Na; Park, Hyung Doo; Kim, Jong Won; Chang, Yun Sil; Park, Won Soon; Lee, Soo Youn

    2015-11-01

    Conventional screening for congenital adrenal hyperplasia (CAH) using immunoassays generates a large number of false-positive results. A more specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been introduced to minimize unnecessary follow-ups. However, because of limited data on its use in the Korean population, LC-MS/MS has not yet been incorporated into newborn screening programs in this region. The present study aims to develop and validate an LC-MS/MS method for the simultaneous determination of seven steroids in dried blood spots (DBS) for CAH screening, and to define age-specific reference intervals in the Korean population. We developed and validated an LC-MS/MS method to determine the reference intervals of cortisol, 17-hydroxyprogesterone, 11-deoxycortisol, 21-deoxycortisol, androstenedione, corticosterone, and 11-deoxycorticosterone simultaneously in 453 DBS samples. The samples were from Korean subjects stratified by age group (78 full-term neonates, 76 premature neonates, 89 children, and 100 adults). The accuracy, precision, matrix effects, and extraction recovery were satisfactory for all the steroids at three concentrations; values of intra- and inter-day precision coefficients of variance, bias, and recovery were 0.7-7.7%, -1.5-9.8%, and 49.3-97.5%, respectively. The linearity range was 1-100 ng/mL for cortisol and 0.5-50 ng/mL for other steroids (R²>0.99). The reference intervals were in agreement with the previous reports. This LC-MS/MS method and the reference intervals validated in the Korean population can be successfully applied to analyze seven steroids in DBS for the diagnosis of CAH.

  11. Effect of 6-8 weeks of oral ursodeoxycholic acid administration on serum concentrations of fasting and postprandial bile acids and biochemical analytes in healthy dogs.

    PubMed

    Deitz, Krysta L; Makielski, Kelly M; Williams, Jackie M; Lin, Hui; Morrison, Jo Ann

    2015-09-01

    Ursodeoxycholic acid (UDCA) is commonly used for the treatment of hepatobiliary disease. UDCA is a bile acid that can be detected in the bile acid assay. Its effect on biochemical analytes is unknown. The aim of this study was to determine the effect of 6-8 weeks of UDCA administration on fasting and postprandial concentrations of serum bile acids (SBA), cholesterol, triglycerides, bilirubin, and liver enzyme activities in healthy dogs. Twenty healthy dogs received UDCA for 6-8 weeks. CBC, biochemistry profile, urinalysis, fasting and postprandial SBA, and hepatobiliary ultrasound examination were performed prior to starting UDCA (timepoint 0) and after 6-8 weeks of therapy, while animals were still receiving UDCA (timepoint 1). Timepoint 0 and timepoint 1 values were compared with a paired t-test. SBA were remeasured 72 hours after UDCA discontinuation. Only mean fasting SBA at timepoint 1 increased significantly (P = .03) from timepoint 0 (2.26 μmol/L at time 0 and 3.81 μmol/L at time 1) but were not elevated above the normal reference interval (0-9 μmol/L). Two dogs had timepoint 1 fasting SBA above the reference interval (10 and 11.7 μmol/L). One dog had timepoint 1 postprandial SBA above the reference interval at 20.1 μmol/L (reference interval 0-17 μmol/L). Repeat SBA 72 hours after UDCA discontinuation were normal. Long-term administration of UDCA to healthy dogs may increase fasting SBA above pretreatment values (typically within the reference interval). Long-term administration of UDCA to healthy dogs does not alter liver enzyme activities, and bilirubin, cholesterol, or triglyceride concentrations. © 2015 American Society for Veterinary Clinical Pathology.

  12. Clinical assessment of gastric emptying and sensory function utilizing gamma scintigraphy: Establishment of reference intervals for the liquid and solid components of the Nottingham test meal in healthy subjects.

    PubMed

    Parker, H L; Tucker, E; Blackshaw, E; Hoad, C L; Marciani, L; Perkins, A; Menne, D; Fox, M

    2017-11-01

    Current investigations of stomach function are based on small test meals that do not reliably induce symptoms and analysis techniques that rarely detect clinically relevant dysfunction. This study presents the reference intervals of the modular "Nottingham test meal" (NTM) for assessment of gastric function by gamma scintigraphy (GSc) in a representative population of healthy volunteers (HVs) stratified for age and sex. The NTM comprises 400 mL liquid nutrient (0.75 kcal/mL) and an optional solid component (12 solid agar-beads (0 kcal). Filling and dyspeptic sensations were documented by 100 mm visual analogue scale (VAS). Gamma scintigraphy parameters that describe early and late phase Gastric emptying (GE) were calculated from validated models. Gastric emptying (GE) of the liquid component was measured in 73 HVs (male 34; aged 45±20). The NTM produced normal postprandial fullness (VAS ≥30 in 41/74 subjects). Dyspeptic symptoms were rare (VAS ≥30 in 2/74 subjects). Gastric emptying half-time with the Liquid- and Solid-component -NTM was median 44 (95% reference interval 28-78) minutes and 162 (144-193) minutes, respectively. Gastric accommodation was assessed by the ratio of the liquid-NTM retained in the proximal:total stomach and by Early phase emptying assessed by gastric volume after completing the meal (GCV0). No consistent effect of anthropometric measures on GE parameters was present. Reference intervals are presented for GSc measurements of gastric motor and sensory function assessed by the NTM. Studies involving patients are required to determine whether the reference interval range offers optimal diagnostic sensitivity and specificity. © 2017 The Authors. Neurogastroenterology & Motility Published by John Wiley & Sons Ltd.

  13. Spatial interpolation of daily reference evapotranspiration in the Texas High Plains

    USDA-ARS?s Scientific Manuscript database

    The Texas High Plains Evapotranspiration (ET) Network collects meteorological data from 18 grass reference weather stations at hourly intervals and estimates hourly and daily reference ET using the American Society of Civil Engineers (ASCE) Standardized Reference ET equation. Producers in the Texas ...

  14. Cord blood calcium, phosphate, magnesium, and alkaline phosphatase gestational age-specific reference intervals for preterm infants.

    PubMed

    Fenton, Tanis R; Lyon, Andrew W; Rose, M Sarah

    2011-08-31

    The objective was to determine the influence of gestational age, maternal, and neonatal variables on reference intervals for cord blood bone minerals (calcium, phosphate, magnesium) and related laboratory tests (alkaline phosphatase, and albumin-adjusted calcium), and to develop gestational age specific reference intervals based on infants without influential pathological conditions. Cross-sectional study. 702 babies were identified as candidates for this study in a regional referral neonatal unit. After exclusions (for anomalies, asphyxia, maternal magnesium sulfate administration, and death), relationships were examined between cord blood serum laboratory analytes (calcium, phosphate, magnesium, alkaline phosphatase, and albumin-adjusted calcium) with gestation age and also with maternal and neonatal variables using multiple linear regression. Infants with influential pathological conditions were omitted from the development of gestational age specific reference intervals for the following categories: 23-27, 28-31, 32-34, 35-36 and > 36 weeks. Among the 506 preterm and 54 terms infants included in the sample. Phosphate, magnesium, and alkaline phosphatase in cord blood serum decreased with gestational age, calcium increased with gestational age. Those who were triplets, small for gestational age, and those whose mother had pregnancy-induced hypertension were influential for most of the analytes. The reference ranges for the preterm infants ≥ 36 weeks were: phosphate 1.5 to 2.6 mmol/L (4.5 to 8.0 mg/dL), calcium: 2.1 to 3.1 mmol/L (8.3 to 12.4 mg/dL); albumin-adjusted calcium: 2.3 to 3.2 mmol/L (9.1 to 12.9 mg/dL); magnesium 0.6 to 1.0 mmol/L (1.4 to 2.3 mg/dL), and alkaline phosphatase 60 to 301 units/L. These data suggest that gestational age, as well as potentially pathogenic maternal and neonatal variables should be considered in the development of reference intervals for preterm infants.

  15. Simplified estimation of age-specific reference intervals for skewed data.

    PubMed

    Wright, E M; Royston, P

    1997-12-30

    Age-specific reference intervals are commonly used in medical screening and clinical practice, where interest lies in the detection of extreme values. Many different statistical approaches have been published on this topic. The advantages of a parametric method are that they necessarily produce smooth centile curves, the entire density is estimated and an explicit formula is available for the centiles. The method proposed here is a simplified version of a recent approach proposed by Royston and Wright. Basic transformations of the data and multiple regression techniques are combined to model the mean, standard deviation and skewness. Using these simple tools, which are implemented in almost all statistical computer packages, age-specific reference intervals may be obtained. The scope of the method is illustrated by fitting models to several real data sets and assessing each model using goodness-of-fit techniques.

  16. Population-based pediatric reference intervals for general clinical chemistry analytes on the Abbott Architect ci8200 instrument.

    PubMed

    Ridefelt, Peter; Aldrimer, Mattias; Rödöö, Per-Olof; Niklasson, Frank; Jansson, Leif; Gustafsson, Jan; Hellberg, Dan

    2012-02-29

    Reference intervals are crucial decision-making tools aiding clinicians in differentiating between healthy and diseased populations. However, for children such values often are lacking or incomplete. Blood samples were obtained from 692 healthy children, aged 6 months to 18 years, recruited in daycare centers and schools. Twelve common general clinical chemistry analytes were measured on the Abbott Architect ci8200 platform; sodium, potassium, chloride, calcium, albumin-adjusted calcium, phosphate, magnesium, creatinine (Jaffe and enzymatic), cystatin C, urea and uric acid. Age- and gender specific pediatric reference intervals were defined by calculating the 2.5th and 97.5th percentiles. The data generated is primarily applicable to a Caucasian population when using the Abbott Architect platform, but could be used by any laboratory if validated for the local patient population.

  17. Significant figures.

    PubMed

    Badrick, Tony; Hickman, Peter E

    2008-08-01

    * For consistency of reporting the same number of significant figures should be used for results and reference intervals. * The choice of the reporting interval should be based on analytical imprecision (measurement uncertainty).

  18. Hematology and Clinical Chemistry Measures During and After Pregnancy and Age- and Sex-Specific Reference Intervals in African Green Monkeys (Chlorocebus aethiops sabaeus).

    PubMed

    Chichester, Lee; Gee, Melaney K; Jorgensen, Matthew J; Kaplan, Jay R

    2015-07-01

    Clinical decisions and experimental analyses often involve the assessment of hematology and clinical chemistry. Using clinical pathology to assess the health status of NHP in breeding colonies or data from studies than involve pregnancy can often be complicated by pregnancy status. This study had 2 objectives regarding the hematology and clinical chemistry of African green monkeys (AGM, Chlorocebus aethiops sabaeus): 1) to compare pregnant or recently postpartum animals with nonpregnant, nonlactating animals and 2) to create age- and sex-specific reference intervals. Subjects in this study were 491 AGM from the Vervet Research Colony of the Wake Forest University Primate Center. Results indicated that changes in BUN, serum total protein, albumin, ALP, GGT, calcium, phosphorus, sodium, potassium, cholesterol, total CO2, globulins, lipase, amylase, WBC, neutrophils, lymphocytes, platelets, RBC, Hgb, and Hct occur during pregnancy and the postpartum period. Age- and sex-specific reference intervals consistent with guidelines from the American Society for Veterinary Clinical Pathology were established and further expand the understanding of how to define health in AGM on the basis of clinical pathology. The combination of understanding the changes that occur in pregnancy and postpartum and expansive reference intervals will help guide clinical and experimental decisions.

  19. Alcohol References on Undergraduate Males’ Facebook Profiles

    PubMed Central

    Egan, Katie G.; Moreno, Megan A.

    2011-01-01

    Perceived peer alcohol use is a predictor of consumption in college males; frequent references to alcohol on Facebook may encourage alcohol consumption. Content analysis of college males’ Facebook profiles identified references to alcohol. The average age of 225 identified profiles was 19.9 years. Alcohol references were present on 85.3% of the profiles; the prevalence of alcohol was similar across each undergraduate grade. The average number of alcohol references per profile was 8.5 but increased with undergraduate year (p = .003; confidence interval = 1.5, 7.5). Students who were of legal drinking age referenced alcohol 4.5 times more than underage students, and an increase in number of Facebook friends was associated with an increase in displayed alcohol references (p < .001; confidence interval = 0.009, 0.02). Facebook is widely used in the college population; widespread alcohol displays on Facebook may influence social norms and cause increases in male college students’ alcohol use. PMID:21406490

  20. Analytical Bias Exceeding Desirable Quality Goal in 4 out of 5 Common Immunoassays: Results of a Native Single Serum Sample External Quality Assessment Program for Cobalamin, Folate, Ferritin, Thyroid-Stimulating Hormone, and Free T4 Analyses.

    PubMed

    Kristensen, Gunn B B; Rustad, Pål; Berg, Jens P; Aakre, Kristin M

    2016-09-01

    We undertook this study to evaluate method differences for 5 components analyzed by immunoassays, to explore whether the use of method-dependent reference intervals may compensate for method differences, and to investigate commutability of external quality assessment (EQA) materials. Twenty fresh native single serum samples, a fresh native serum pool, Nordic Federation of Clinical Chemistry Reference Serum X (serum X) (serum pool), and 2 EQA materials were sent to 38 laboratories for measurement of cobalamin, folate, ferritin, free T4, and thyroid-stimulating hormone (TSH) by 5 different measurement procedures [Roche Cobas (n = 15), Roche Modular (n = 4), Abbott Architect (n = 8), Beckman Coulter Unicel (n = 2), and Siemens ADVIA Centaur (n = 9)]. The target value for each component was calculated based on the mean of method means or measured by a reference measurement procedure (free T4). Quality specifications were based on biological variation. Local reference intervals were reported from all laboratories. Method differences that exceeded acceptable bias were found for all components except folate. Free T4 differences from the uncommonly used reference measurement procedure were large. Reference intervals differed between measurement procedures but also within 1 measurement procedure. The serum X material was commutable for all components and measurement procedures, whereas the EQA materials were noncommutable in 13 of 50 occasions (5 components, 5 methods, 2 EQA materials). The bias between the measurement procedures was unacceptably large in 4/5 tested components. Traceability to reference materials as claimed by the manufacturers did not lead to acceptable harmonization. Adjustment of reference intervals in accordance with method differences and use of commutable EQA samples are not implemented commonly. © 2016 American Association for Clinical Chemistry.

  1. Lack of harmonization in sweat testing for cystic fibrosis - a national survey.

    PubMed

    Christiansen, Anne Lindegaard; Nybo, Mads

    2014-11-01

    Sweat testing is used in the diagnosis of cystic fibrosis. Interpretation of the sweat test depends, however, on the method performed since conductivity, osmolality and chloride concentration all can be measured as part of a sweat test. The aim of this study was to investigate how performance of the test is organized in Denmark. Departments conducting the sweat test were contacted and interviewed following a premade questionnaire. They were asked about methods performed, applied NPU (Nomenclature for Properties and Units) code, reference interval, recommended interpretation and referred literature. 14 departments performed the sweat test. One department measured chloride and sodium concentration, while 13 departments measured conductivity. One department used a non-existing NPU code, two departments applied NPU codes inconsistent with the method performed, four departments applied no NPU code and seven applied a correct NPU code. Ten of the departments measuring conductivity applied reference intervals. Nine departments measuring conductivity had recommendations of a normal area, a grey zone and a pathological value, while four departments only applied a normal and grey zone or a pathological value. Cut-off values for normal, grey and pathological areas were like the reference intervals inconsistent. There is inconsistent use of NPU codes, reference intervals and interpretation of sweat conductivity used in the process of diagnosing cystic fibrosis. Because diagnosing cystic fibrosis is a combined effort between local pediatric departments, biochemical and genetic departments and cystic fibrosis centers, a national harmonization is necessary to assure correct clinical use.

  2. EXPLORATORY PLASMA BIOCHEMISTRY REFERENCE INTERVALS FOR URAL OWLS (STRIX URALENSIS, PALLAS 1771) FROM THE AUSTRIAN REINTRODUCTION PROJECT.

    PubMed

    Scope, Alexandra; Schwendenwein, Ilse; Stanclova, Gabriela; Vobornik, Angela; Zink, Richard

    2016-06-01

    The Ural owl (Strix uralensis) is the biggest forest-living owl in Austria; however, it became extinct in Austria through poaching and habitat loss more than half a century ago. The birds examined in the present study were breeding pairs from the reintroduction project with the aim of determining exploratory plasma biochemistry reference intervals in Ural owls and evaluating the amount of biological variation between seasons, sexes, and ages. A total of 45 birds were sampled, including 13 adult males, 14 adult females, and 18 juvenile birds. Remarkably, almost all of the analytes showed significant differences between the subgroups, primarily between seasons, followed by age and sex. Only creatinkinase, glucose, lactatdehydrogenase, and triglycerides did not show any significant variations. Despite partitioning of reference values into subgroups according to biological variation diminishing the number of reference individuals in the respective groups, the resulting smaller reference intervals will improve medical assessment. The results of the present study once again demonstrate that significant seasonal fluctuations must be expected and considered in the interpretation. It can be assumed that these differences are probably even greater in free-range birds with considerable changes in food quantity and quality during and between years.

  3. Androgen profiling by liquid chromatography-tandem mass spectrometry (LC-MS/MS) in healthy normal-weight ovulatory and anovulatory late adolescent and young women.

    PubMed

    Fanelli, Flaminia; Gambineri, Alessandra; Belluomo, Ilaria; Repaci, Andrea; Di Lallo, Valentina Diana; Di Dalmazi, Guido; Mezzullo, Marco; Prontera, Olga; Cuomo, Gaia; Zanotti, Laura; Paccapelo, Alexandro; Morselli-Labate, Antonio Maria; Pagotto, Uberto; Pasquali, Renato

    2013-07-01

    Physiological transient imbalance typical of adolescence needs to be distinguished from hyperandrogenism-related dysfunction. The accurate determination of circulating androgens is the best indicator of hyperandrogenism. However, reliable reference intervals for adolescent and young women are not available. The aim of the study was to define androgen reference intervals in young women and to analyze the impact of the menstrual phase and ovulation efficiency over the androgen profile as assessed by reliable liquid chromatography-tandem mass spectrometry (LC-MS/MS) technique. Female high school students aged 16-19 years were included in the study. The study was performed on reference subjects properly selected among an unbiased population. Normal-weight, drug and disease free, eumenorrheic females with no signs of hyperandrogenism were included. The steroid hormone profile was determined by a validated in-house LC-MS/MS method. A statistical estimation of overall and menstrual phase-specific reference intervals was performed. A subgroup of anovulatory females was identified based on progesterone circulating levels. The impact of ovulation efficiency over hormonal profile was analyzed. A total of 159 females satisfied healthy criteria. Androgen levels did not vary according to menstrual phase, but a significantly higher upper reference limit was found for T in the luteal phase compared to the follicular phase. Higher T and androstenedione levels were observed in anovulatory compared to ovulatory females, paralleled by higher LH and FSH and lower 17-hydroxyprogesterone and 17β-estradiol levels. This is the first study providing LC-MS/MS-based, menstrual phase-specific reference intervals for the circulating androgen profile in young females. We identified a subgroup of anovulatory healthy females characterized by androgen imbalance.

  4. Hematology and Serum Biochemistry Reference Intervals for Six-Week-Old, Farm-Reared Chinese Ring-Necked Pheasants ( Phasianus colchicus ) from Minnesota.

    PubMed

    Dzikamunhenga, R S; Griffith, R W; Hostetter, S; Fisher, P; Larson, W

    2017-06-01

    Chinese ring-necked pheasants ( Phasianus colchicus ) are commonly farmed in intensive operations for purposes such as meat production, hunting preserves, or research. Under these conditions, pheasants frequently suffer medical ailments such as bacterial, viral, and parasitic infections or nutritional or metabolic disorders. Relatively little scientific information exists regarding clinical pathology reference intervals (RIs) for farm-reared pheasants. The objective of this study was to determine RIs for hematologic and serum biochemical variables for Chinese ring-necked pheasants from Minnesota at 6 wk of age. Blood samples from 119 clinically healthy Chinese ring-necked pheasants were analyzed using standard techniques. Reference intervals were generated in Microsoft® Excel® 2013 (Microsoft, Redmond, WA) using Reference Value Advisor freeware version 2.1 (Microsoft). Ninety-five percent RIs were determined using nonparametric methods that followed Clinical and Laboratory Standards Institute guidelines. These RIs will be useful for the monitoring of health and diagnosis of disease in confined Chinese ring-necked pheasant populations that are approximately 6 wk old.

  5. EFFECT ON PERFUSION VALUES OF SAMPLING INTERVAL OF CT PERFUSION ACQUISITIONS IN NEUROENDOCRINE LIVER METASTASES AND NORMAL LIVER

    PubMed Central

    Ng, Chaan S.; Hobbs, Brian P.; Wei, Wei; Anderson, Ella F.; Herron, Delise H.; Yao, James C.; Chandler, Adam G.

    2014-01-01

    Objective To assess the effects of sampling interval (SI) of CT perfusion acquisitions on CT perfusion values in normal liver and liver metastases from neuroendocrine tumors. Methods CT perfusion in 16 patients with neuroendocrine liver metastases were analyzed by distributed parameter modeling to yield tissue blood flow, blood volume, mean transit time, permeability, and hepatic arterial fraction, for tumor and normal liver. CT perfusion values for the reference sampling interval of 0.5s (SI0.5) were compared with those of SI datasets of 1s, 2s, 3s and 4s, using mixed-effects model analyses. Results Increases in SI beyond 1s were associated with significant and increasing departures of CT perfusion parameters from reference values at SI0.5 (p≤0.0009). CT perfusion values deviated from reference with increasing uncertainty with increasing SIs. Findings for normal liver were concordant. Conclusion Increasing SIs beyond 1s yield significantly different CT perfusion parameter values compared to reference values at SI0.5. PMID:25626401

  6. Considering User's Access Pattern in Multimedia File Systems

    NASA Astrophysics Data System (ADS)

    Cho, KyoungWoon; Ryu, YeonSeung; Won, Youjip; Koh, Kern

    2002-12-01

    Legacy buffer cache management schemes for multimedia server are grounded at the assumption that the application sequentially accesses the multimedia file. However, user access pattern may not be sequential in some circumstances, for example, in distance learning application, where the user may exploit the VCR-like function(rewind and play) of the system and accesses the particular segments of video repeatedly in the middle of sequential playback. Such a looping reference can cause a significant performance degradation of interval-based caching algorithms. And thus an appropriate buffer cache management scheme is required in order to deliver desirable performance even under the workload that exhibits looping reference behavior. We propose Adaptive Buffer cache Management(ABM) scheme which intelligently adapts to the file access characteristics. For each opened file, ABM applies either the LRU replacement or the interval-based caching depending on the Looping Reference Indicator, which indicates that how strong temporally localized access pattern is. According to our experiment, ABM exhibits better buffer cache miss ratio than interval-based caching or LRU, especially when the workload exhibits not only sequential but also looping reference property.

  7. Versatile all-digital time interval measuring system

    NASA Astrophysics Data System (ADS)

    Vyhlidal, David; Cech, Miroslav

    2011-06-01

    This paper describes a design and performance of a versatile all-digital time interval measuring system. The measurement method is based on an interpolation principle. In this principle the time interval is first roughly digitized by a coarse counter driven by a high stability reference clock and the fractions between the clock periods are measured by two Time-to-Digital Converter chips TDC-GPX manufactured by Acam messelectronic. Control circuits allow programmable customization of the system to satisfy many applications such as laser range finding, event counting, or time-of-flight measurements in various physics experiments. The system has two reference clocks inputs and two independent channels for measuring start and stop events. Only one 40 MHz reference is required for the measurement. The second reference can be, for example, 1 PPS (Pulse per Second) signal from a GPS (Global Positioning System) to time tag events. Time intervals are measured using the highest resolution mode of the TDC-GPX chips. The resolution of each chip is software programmable and is PLL (Phase Locked Loop) stabilized against temperature and voltage variations. The system can achieve a timing resolution better than 15 ps rms with up to 90 kHz repetition rate. The time interval measurement range is from 0 ps up to 1 second. The power consumption of the whole system is 18 W including an embedded computer board and an LCD (Liquid Crystal Display) screen. The embedded computer controls the whole system, collects and evaluates measurement data and with the display provides a user interface. The system is implemented using commercially available components.

  8. Hematologic and serum biochemical reference intervals for free-ranging common bottlenose dolphins (Tursiops truncatus) and variation in the distributions of clinicopathologic values related to geographic sampling site.

    PubMed

    Schwacke, Lori H; Hall, Ailsa J; Townsend, Forrest I; Wells, Randall S; Hansen, Larry J; Hohn, Aleta A; Bossart, Gregory D; Fair, Patricia A; Rowles, Teresa K

    2009-08-01

    To develop robust reference intervals for hematologic and serum biochemical variables by use of data derived from free-ranging bottlenose dolphins (Tursiops truncatus) and examine potential variation in distributions of clinicopathologic values related to sampling sites' geographic locations. 255 free-ranging bottlenose dolphins. Data from samples collected during multiple bottlenose dolphin capture-release projects conducted at 4 southeastern US coastal locations in 2000 through 2006 were combined to determine reference intervals for 52 clinicopathologic variables. A nonparametric bootstrap approach was applied to estimate 95th percentiles and associated 90% confidence intervals; the need for partitioning by length and sex classes was determined by testing for differences in estimated thresholds with a bootstrap method. When appropriate, quantile regression was used to determine continuous functions for 95th percentiles dependent on length. The proportion of out-of-range samples for all clinicopathologic measurements was examined for each geographic site, and multivariate ANOVA was applied to further explore variation in leukocyte subgroups. A need for partitioning by length and sex classes was indicated for many clinicopathologic variables. For each geographic site, few significant deviations from expected number of out-of-range samples were detected. Although mean leukocyte counts did not vary among sites, differences in the mean counts for leukocyte subgroups were identified. Although differences in the centrality of distributions for some variables were detected, the 95th percentiles estimated from the pooled data were robust and applicable across geographic sites. The derived reference intervals provide critical information for conducting bottlenose dolphin population health studies.

  9. Determination of strong ion gap in healthy dogs.

    PubMed

    Fettig, Pamela K; Bailey, Dennis B; Gannon, Kristi M

    2012-08-01

    To determine and compare reference intervals of the strong ion gap (SIG) in a group of healthy dogs determined with 2 different equations. Prospective observational study. Tertiary referral and teaching hospital. Fifty-four healthy dogs. None. Serum biochemistry and blood gas analyses were performed for each dog. From these values, SIG was calculated using 2 different equations: SIG(1) = SID(a) {[Na (+)] + [K(+)] - [Cl(-)]+ [2 × Ca(2+)] + [2 × Mg(2+)] - [L-lactate]}- SID(e) {TCO(2) + A(-)} and SIG(2) = [albumin] × 4.9-anion gap. Reference intervals were established for each SIG equation using the mean ± 1.96 × standard deviation (SD). For SIG(1), the median was 7.13 mEq/L (range, 1.05-11.30 mEq/L) and the derived reference interval was 1.85-10.61 mEq/L. Median SIG(2) was -0.22 mEq/L (range, -5.34-6.61 mEq/L) and the mean SIG(2) was -0.09 mEq/L (95% confidence interval for the mean, -0.82-0.65 mEq/L). The derived reference interval was -5.36-5.18 mEq/L. The results of the SIG calculations were significantly different (P < 0.0001) between the 2 equations used. The 2 equations used to calculate SIG yielded significantly different results and cannot be used interchangeably. The authors believe SIG(2) to be a more accurate reflection of acid-base status in healthy dogs, and recommend that this calculation be used for future studies. © Veterinary Emergency and Critical Care Society 2012.

  10. Genetics Home Reference: Romano-Ward syndrome

    MedlinePlus

    ... part of the heartbeat known as the QT interval is abnormally long. Abnormalities in the time it ... those types that involve only a long QT interval without other abnormalities. Related Information What does it ...

  11. Genetics Home Reference: ankyrin-B syndrome

    MedlinePlus

    ... beats, which is known as a prolonged QT interval (long QT). Some affected individuals have impaired progression ( ... sudden death. When associated with a prolonged QT interval, the condition is sometimes classified as long QT ...

  12. Reference intervals for plasma concentrations of adrenal steroids measured by LC-MS/MS: Impact of gender, age, oral contraceptives, body mass index and blood pressure status.

    PubMed

    Eisenhofer, Graeme; Peitzsch, Mirko; Kaden, Denise; Langton, Katharina; Pamporaki, Christina; Masjkur, Jimmy; Tsatsaronis, George; Mangelis, Anastasios; Williams, Tracy A; Reincke, Martin; Lenders, Jacques W M; Bornstein, Stefan R

    2017-07-01

    Mass spectrometric-based measurements of the steroid metabolome have been introduced to diagnose disorders featuring abnormal steroidogenesis. Defined reference intervals are important for interpreting such data. Liquid chromatography-tandem mass spectrometry was used to establish reference intervals for 16 steroids (pregnenolone, progesterone, 11-deoxycorticosterone, corticosterone, aldosterone, 18-oxocortisol, 18-hydroxycortisol, 17-hydroxyprogesterone, 21-deoxycortisol, 11-deoxycortisol, cortisol, cortisone, dehydroepiandrosterone, dehydroepiandrosterone-sulfate, androstenedione, testosterone) measured in plasma from 525 volunteers with (n=227) and without (n=298) hypertension, including 68 women on oral contraceptives. Women showed variable plasma concentrations of several steroids associated with menstrual cycle phase, menopause and oral contraceptive use. Progesterone was higher in females than males, but most other steroids were higher in males than females and almost all declined with advancing age. Using models that corrected for age and gender, body mass index showed weak negative relationships with corticosterone, 21-deoxycortisol, cortisol, cortisone, testosterone, progesterone, 17-hydroxyprogesterone and 11-deoxycorticosterone, but a positive relationship with 18-hydroxycortisol. Hypertensives and normotensives showed negligible differences in plasma concentrations of steroids. Age and gender are the most important variables for plasma steroid reference intervals, which have been established here according to those variables for a panel of 16 steroids primarily useful for diagnosis and subtyping of patients with endocrine hypertension. Copyright © 2017. Published by Elsevier B.V.

  13. Development of paediatric biochemistry centile charts as a complement to laboratory reference intervals.

    PubMed

    Loh, Tze Ping; Antoniou, Georgia; Baghurst, Peter; Metz, Michael P

    2014-06-01

    Age-specific paediatric reference intervals are used in interpretation of laboratory results. However, interpretation may be problematic when a child just crosses an age bracket and the difference between the original and the subsequent age-specific reference interval is large. Moreover, details about the physiological changes with age may be masked. For the 12 months ending 30 September 2013, results of 16 common clinical biochemistry tests of ambulatory paediatric patients aged 0-19, requested by primary care physicians, were retrospectively collected in a large pathology service, and used to construct smoothed centile charts using a penalised maximum likelihood method. From the developed centile charts, the concentrations of sodium, bicarbonate, creatinine, urate, total protein, and albumin all increased with increasing age of the children. In contrast, the concentrations of potassium, chloride, anion gap, calcium, phosphate and lactate dehydrogenase decreased with increasing age of the children. Changes in the concentrations of urea, alkaline phosphatase, glucose, and total cholesterol varied by age. Generally, the boys and girls shared similar trend patterns until 10-15 years of age, when variations in the age of onset of puberty and development caused the trends of some biochemical measures to differ. The paediatric biochemistry centile charts are intuitive tools to use. They complement age-specific reference intervals in the tracking, interpretation and discussion of laboratory results. They also enhance the understanding of underlying physiological changes in biochemistry in children.

  14. Genetics and fine mapping of a purple leaf gene, BoPr, in ornamental kale (Brassica oleracea L. var. acephala).

    PubMed

    Liu, Xiao-Ping; Gao, Bao-Zhen; Han, Feng-Qing; Fang, Zhi-Yuan; Yang, Li-Mei; Zhuang, Mu; Lv, Hong-Hao; Liu, Yu-Mei; Li, Zhan-Sheng; Cai, Cheng-Cheng; Yu, Hai-Long; Li, Zhi-Yuan; Zhang, Yang-Yong

    2017-03-14

    Due to its variegated and colorful leaves, ornamental kale (Brassica oleracea L. var. acephala) has become a popular ornamental plant. In this study, we report the fine mapping and analysis of a candidate purple leaf gene using a backcross population and an F 2 population derived from two parental lines: W1827 (with white leaves) and P1835 (with purple leaves). Genetic analysis indicated that the purple leaf trait is controlled by a single dominant gene, which we named BoPr. Using markers developed based on the reference genome '02-12', the BoPr gene was preliminarily mapped to a 280-kb interval of chromosome C09, with flanking markers M17 and BoID4714 at genetic distances of 4.3 cM and 1.5 cM, respectively. The recombination rate within this interval is almost 12 times higher than the usual level, which could be caused by assembly error for reference genome '02-12' at this interval. Primers were designed based on 'TO1000', another B. oleracea reference genome. Among the newly designed InDel markers, BRID485 and BRID490 were found to be the closest to BoPr, flanking the gene at genetic distances of 0.1 cM and 0.2 cM, respectively; the interval between the two markers is 44.8 kb (reference genome 'TO1000'). Seven annotated genes are located within the 44.8 kb genomic region, of which only Bo9g058630 shows high homology to AT5G42800 (dihydroflavonol reductase), which was identified as a candidate gene for BoPr. Blast analysis revealed that this 44.8 kb interval is located on an unanchored scaffold (Scaffold000035_P2) of '02-12', confirming the existence of assembly error at the interval between M17 and BoID4714 for reference genome '02-12'. This study identified a candidate gene for BoPr and lays a foundation for the cloning and functional analysis of this gene.

  15. Non-transference of biological reference interval of TSH by electrochemiluminescence immunoassay: an Indian population perspective.

    PubMed

    Sarkar, Rajarshi

    2013-08-23

    Although TSH measurement by electrochemiluminescence immunoassay has become commonplace in India, significant discrepancy has been observed on interpretation of the test results when the manufacturer supplied biological reference interval (BRI) criteria were applied. This report determined whether the manufacturer's BRI (Roche Cobas) is transferable to the Indian population. Three hundred seventy-eight age- and sex-matched healthy subjects were selected from an urban Indian population. TSH reference measurements were acquired, and the reference data were statistically analysed. BRI of the Indian urban reference population was determined by non-parametric means. BRI was found to be 1.134 to 7.280μIU/ml. BRI thus calculated was found to be significantly different from that mentioned by the manufacturer (0.27 to 4.20μIU/ml), which, needless to mention, has profound clinical implications in this part of the globe. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Gestation-specific reference intervals for comprehensive spot urinary steroid hormone metabolite analysis in normal singleton pregnancy and 6 weeks postpartum.

    PubMed

    Mistry, Hiten D; Eisele, Nicole; Escher, Geneviève; Dick, Bernhard; Surbek, Daniel; Delles, Christian; Currie, Gemma; Schlembach, Dietmar; Mohaupt, Markus G; Gennari-Moser, Carine

    2015-09-04

    Normal pregnancy depends on pronounced adaptations in steroid hormone concentrations. Although in recent years, the understanding of these hormones in pregnancy has improved, the interpretation is hampered by insufficient reference values. Our aim was to establish gestation-specific reference intervals for spot urinary steroid hormone levels in normal singleton pregnancies and 6 weeks postpartum. Cross-sectional multicentre observational study. Women recruited between 2008 and 2013 at 3 University Hospitals in Switzerland (Bern), Scotland (Glasgow) and Austria (Graz). Spot urine was collected from healthy women undergoing a normal pregnancy (age, 16-45 years; mean, 31 years) attending routine antenatal clinics at gestation weeks 11, 20, and 28 and approximately 6 weeks postpartum. Urine steroid hormone levels were analysed using gas-chromatography mass spectrometry. Creatinine was also measured by routine analysis and used for normalisation. From the results, a reference interval was calculated for each hormone metabolite at each trimester and 6 weeks postpartum. Changes in these concentrations between trimesters and postpartum were also observed for several steroid hormones and followed changes proposed for index steroid hormones. Normal gestation-specific reference values for spot urinary steroid hormones throughout pregnancy and early postpartum are now available to facilitate clinical management and research approaches to steroid hormone metabolism in pregnancy and the early postpartum period.

  17. Development of gestation-specific reference intervals for thyroid hormones in normal pregnant Northeast Chinese women: What is the rational division of gestation stages for establishing reference intervals for pregnancy women?

    PubMed

    Liu, Jianhua; Yu, Xiaojun; Xia, Meng; Cai, Hong; Cheng, Guixue; Wu, Lina; Li, Qiang; Zhang, Ying; Sheng, Mengyuan; Liu, Yong; Qin, Xiaosong

    2017-04-01

    A laboratory- and region-specific trimester-related reference interval for thyroid hormone assessment of pregnant women was recommended. Whether the division by trimester is suitable requires verification. Here, we tried to establish appropriate reference intervals of thyroid-related hormones and antibodies for normal pregnant women in Northeast China. A total of 947 pregnant women who underwent routine prenatal care were grouped via two methods. The first method entailed division by trimester: stages T1, T2, and T3. The second method entailed dividing T1, T2, and T3 stages into two stages each: T1-1, T1-2, T2-1, T2-2, T3-1, and T3-2. Serum levels of TSH, FT3, FT4, Anti-TPO, and Anti-TG were measured by three detection systems. No significant differences were found in TSH values between T1-1 group and the non-pregnant women group. However, the TSH value of the T1-1 group was significantly higher than that of T1-2 group (P<0.05). The TSH values in stage T3-2 increased significantly compared to those in stage T3-1 measured by three different assays (P<0.05). FT4 and FT3 values decreased significantly in the T2-1 and T2-2 stages compared to the previous stage (P<0.05). The serum levels of Anti-TPO and Anti-TG were not having significant differences between the six stages. The diagnosis and treatment of thyroid dysfunction during pregnancy should base on pregnancy- and method-specific reference intervals. More detailed staging is required to assess the thyroid function of pregnant women before 20 gestational weeks. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  18. Reference values for 27 clinical chemistry tests in 70-year-old males and females.

    PubMed

    Carlsson, Lena; Lind, Lars; Larsson, Anders

    2010-01-01

    Reference values are usually defined based on blood samples from healthy men or nonpregnant women in the age range of 20-50 years. These values are not optimal for elderly patients, as many biological markers change over time and adequate reference values are important for correct clinical decisions. To validate NORIP (Nordic Reference Interval Project) reference values in a 70-year-old population. We studied 27 frequently used laboratory tests. The 2.5th and 97.5th percentiles for these markers were calculated according to the recommendations of the International Federation of Clinical Chemistry on the statistical treatment of reference values. Reference values are reported for plasma alanine aminotransferase, albumin, alkaline phosphatase, pancreas amylase, apolipoprotein A1, apolipoprotein B, aspartate aminotransferase, bilirubin, calcium, chloride, cholesterol, creatinine, creatine kinase, C-reactive protein, glucose, gamma-glutamyltransferase, HDL-cholesterol, iron, lactate dehydrogenase, LDL-cholesterol, magnesium, phosphate, potassium, sodium, transferrin, triglycerides, urate and urea. Reference values calculated from the whole population and a subpopulation without cardiovascular disease showed strong concordance. Several of the reference interval limits were outside the 90% CI of a Scandinavian population (NORIP). 2009 S. Karger AG, Basel.

  19. Age-related reference intervals for free and total prostate-specific antigen in a Singaporean population.

    PubMed

    Saw, S; Aw, T C

    2000-11-01

    Cancer of the prostate is the sixth most frequently found cancer in Singapore. Prostate-specific antigen (PSA) is the most clinically useful tumour marker available today for the diagnosis and management of prostate cancer. To enhance the value of PSA as a screening test we developed age-specific intervals for our ethnic population. The measurement of free PSA was included in the study to calculate the free:total ratio which enhances the differential diagnosis of prostate cancer from benign prostatic hyperplasia or prostatitis. The total PSA upper limits of 10-year intervals, beginning at 30-years-old, were 1.4, 1.7, 2.3, 4.0, 6.3 and 6.6 microg/l. Free PSA cut-off limits were 0.4, 0.5, 0.5, 1.0, 1.5 and 1.6 microg/l. The free:total ratio of PSA was not age dependent. Abbott AxSym standardised their calibration material for both free and total PSA assays with the Stanford 90:10 reference material. This laboratory has implemented these age-specific reference intervals and are currently following up their pick-up rate in the detection of prostate cancer.

  20. Genetics Home Reference: Jervell and Lange-Nielsen syndrome

    MedlinePlus

    ... KCNQ1 or KCNE1 mutation have a long QT interval with related heart abnormalities, but their hearing is ... disease Jervell-Lange Nielsen syndrome JLNS prolonged QT interval in EKG and sudden death surdo-cardiac syndrome ...

  1. Harmonising Adult and Paediatric Reference Intervals in Australia and New Zealand: An Evidence-Based Approach for Establishing a First Panel of Chemistry Analytes

    PubMed Central

    Tate, Jillian R; Sikaris, Ken A; Jones, Graham RD; Yen, Tina; Koerbin, Gus; Ryan, Julie; Reed, Maxine; Gill, Janice; Koumantakis, George; Hickman, Peter; Graham, Peter

    2014-01-01

    Scientific evidence supports the use of common reference intervals (RIs) for many general chemistry analytes, in particular those with sound calibration and traceability in place. Already the Nordic countries and United Kingdom have largely achieved harmonised RIs. Following a series of workshops organised by the Australasian Association of Clinical Biochemists (AACB) between 2012 and 2014 at which an evidence-based approach for determination of common intervals was developed, pathology organisations in Australia and New Zealand have reached a scientific consensus on what adult and paediatric intervals we should use across Australasia. The aim of this report is to describe the processes that the AACB and the Royal College of Pathologists of Australasia have taken towards recommending the implementation of a first panel of common RIs for use in Australasia. PMID:25678727

  2. Vadose zone isobaric well

    DOEpatents

    Hubbell, Joel M.; Sisson, James B.

    2001-01-01

    A deep tensiometer is configured with an outer guide tube having a vented interval along a perforate section at its lower end, which is isolated from atmospheric pressure at or above grade. A transducer having a monitoring port and a reference port is located within a coaxial inner guide tube. The reference port of the transducer is open to the vented interval of the outer guide tube, which has the same gas pressure as in the sediment surrounding the tensiometer. The reference side of the pressure transducer is thus isolated from the effects of atmospheric pressure changes and relative to pressure changes in the material surrounding the tensiometer measurement location and so it is automatically compensated for such pressure changes.

  3. Reference values assessment in a Mediterranean population for small dense low-density lipoprotein concentration isolated by an optimized precipitation method.

    PubMed

    Fernández-Cidón, Bárbara; Padró-Miquel, Ariadna; Alía-Ramos, Pedro; Castro-Castro, María José; Fanlo-Maresma, Marta; Dot-Bach, Dolors; Valero-Politi, José; Pintó-Sala, Xavier; Candás-Estébanez, Beatriz

    2017-01-01

    High serum concentrations of small dense low-density lipoprotein cholesterol (sd-LDL-c) particles are associated with risk of cardiovascular disease (CVD). Their clinical application has been hindered as a consequence of the laborious current method used for their quantification. Optimize a simple and fast precipitation method to isolate sd-LDL particles and establish a reference interval in a Mediterranean population. Forty-five serum samples were collected, and sd-LDL particles were isolated using a modified heparin-Mg 2+ precipitation method. sd-LDL-c concentration was calculated by subtracting high-density lipoprotein cholesterol (HDL-c) from the total cholesterol measured in the supernatant. This method was compared with the reference method (ultracentrifugation). Reference values were estimated according to the Clinical and Laboratory Standards Institute and The International Federation of Clinical Chemistry and Laboratory Medicine recommendations. sd-LDL-c concentration was measured in serums from 79 subjects with no lipid metabolism abnormalities. The Passing-Bablok regression equation is y = 1.52 (0.72 to 1.73) + 0.07 x (-0.1 to 0.13), demonstrating no significant statistical differences between the modified precipitation method and the ultracentrifugation reference method. Similarly, no differences were detected when considering only sd-LDL-c from dyslipidemic patients, since the modifications added to the precipitation method facilitated the proper sedimentation of triglycerides and other lipoproteins. The reference interval for sd-LDL-c concentration estimated in a Mediterranean population was 0.04-0.47 mmol/L. An optimization of the heparin-Mg 2+ precipitation method for sd-LDL particle isolation was performed, and reference intervals were established in a Spanish Mediterranean population. Measured values were equivalent to those obtained with the reference method, assuring its clinical application when tested in both normolipidemic and dyslipidemic subjects.

  4. Reference intervals for acute phase protein and serum protein electrophoresis values in captive Asian elephants (Elephas maximus).

    PubMed

    Isaza, Ramiro; Wiedner, Ellen; Hiser, Sarah; Cray, Carolyn

    2014-09-01

    Acute phase protein (APP) immunoassays and serum protein electrophoresis (SPEP) are assays for evaluating the inflammatory response and have use as diagnostic tools in a variety of species. Acute phase proteins are markers of inflammation that are highly conserved across different species while SPEP separates and quantifies serum protein fractions based on their physical properties. In the current study, serum samples from 35 clinically healthy Asian elephants (Elephas maximus) were analyzed using automated assays for C-reactive protein, serum amyloid A, and haptoglobin and SPEP. Robust methods were used to generate reference intervals for the APPs: C-reactive protein (1.3-12.8 mg/l), serum amyloid A (0-47.5 mg/l), and haptoglobin (0-1.10 mg/ml). In addition, SPEP was performed on these samples to establish reference intervals for each protein fraction. A combination of APPs and SPEP measurements are valuable adjunctive diagnostic tools in elephant health care. © 2014 The Author(s).

  5. Self-calibrating threshold detector

    NASA Technical Reports Server (NTRS)

    Barnes, J. R.; Huang, M. Y. (Inventor)

    1980-01-01

    A self calibrating threshold detector comprises a single demodulating channel which includes a mixer having one input receiving the incoming signal and another input receiving a local replica code. During a short time interval, an incorrect local code is applied to the mixer to incorrectly demodulate the incoming signal and to provide a reference level that calibrates the noise propagating through the channel. A sample and hold circuit is coupled to the channel for storing a sample of the reference level. During a relatively long time interval, the correct replica code provides an output level which ranges between the reference level and a maximum level that represents incoming signal presence and synchronism with the replica code. A summer substracts the stored sample reference from the output level to provide a resultant difference signal indicative of the acquisition of the expected signal.

  6. Consumer Choice Between Hospital-Based and Freestanding Facilities for Arthroscopy: Impact on Prices, Spending, and Surgical Complications.

    PubMed

    Robinson, James C; Brown, Timothy T; Whaley, Christopher; Bozic, Kevin J

    2015-09-16

    Hospital-based outpatient departments traditionally charge higher prices for ambulatory procedures, compared with freestanding surgery centers. Under emerging reference-based benefit designs, insurers establish a contribution limit that they will pay, requiring the patient to pay the difference between that contribution limit and the actual price charged by the facility. The purpose of this study was to evaluate the impact of reference-based benefits on consumer choices, facility prices, employer spending, and surgical outcomes for orthopaedic procedures performed at ambulatory surgery centers. We obtained data on 3962 patients covered by the California Public Employees' Retirement System (CalPERS) who underwent arthroscopy of the knee or shoulder in the three years prior to the implementation of reference-based benefits in January 2012 and on 2505 patients covered by CalPERS who underwent arthroscopy in the two years after implementation. Control group data were obtained on 57,791 patients who underwent arthroscopy and were not subject to reference-based benefits. The impact of reference-based benefits on consumer choices between hospital-based and freestanding facilities, facility prices, employer spending, and surgical complications was assessed with use of difference-in-differences multivariable regressions to adjust for patient demographic characteristics, comorbidities, and geographic location. By the second year of the program, the shift to reference-based benefits was associated with an increase in the utilization of freestanding ambulatory surgery centers by 14.3 percentage points (95% confidence interval, 8.1 to 20.5 percentage points) for knee arthroscopy and by 9.9 percentage points (95% confidence interval, 3.2 to 16.7 percentage points) for shoulder arthroscopy and a corresponding decrease in the use of hospital-based facilities. The mean price paid by CalPERS fell by 17.6% (95% confidence interval, -24.9% to -9.6%) for knee procedures and by 17.0% (95% confidence interval, -29.3% to -2.5%) for shoulder procedures. The shift to reference-based benefits was not associated with a change in the rate of surgical complications. In the first two years after the implementation of reference-based benefits, CalPERS saved $2.3 million (13%) on these two orthopaedic procedures. Reference-based benefits increase consumer sensitivity to price differences between freestanding and hospital-based surgical facilities. This study shows that the implementation of reference-based benefits does not result in a significant increase in measured complication rates for those subject to reference-based benefits. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  7. Consumer Choice Between Hospital-Based and Freestanding Facilities for Arthroscopy

    PubMed Central

    Robinson, James C.; Brown, Timothy T.; Whaley, Christopher; Bozic, Kevin J.

    2015-01-01

    Background: Hospital-based outpatient departments traditionally charge higher prices for ambulatory procedures, compared with freestanding surgery centers. Under emerging reference-based benefit designs, insurers establish a contribution limit that they will pay, requiring the patient to pay the difference between that contribution limit and the actual price charged by the facility. The purpose of this study was to evaluate the impact of reference-based benefits on consumer choices, facility prices, employer spending, and surgical outcomes for orthopaedic procedures performed at ambulatory surgery centers. Methods: We obtained data on 3962 patients covered by the California Public Employees’ Retirement System (CalPERS) who underwent arthroscopy of the knee or shoulder in the three years prior to the implementation of reference-based benefits in January 2012 and on 2505 patients covered by CalPERS who underwent arthroscopy in the two years after implementation. Control group data were obtained on 57,791 patients who underwent arthroscopy and were not subject to reference-based benefits. The impact of reference-based benefits on consumer choices between hospital-based and freestanding facilities, facility prices, employer spending, and surgical complications was assessed with use of difference-in-differences multivariable regressions to adjust for patient demographic characteristics, comorbidities, and geographic location. Results: By the second year of the program, the shift to reference-based benefits was associated with an increase in the utilization of freestanding ambulatory surgery centers by 14.3 percentage points (95% confidence interval, 8.1 to 20.5 percentage points) for knee arthroscopy and by 9.9 percentage points (95% confidence interval, 3.2 to 16.7 percentage points) for shoulder arthroscopy and a corresponding decrease in the use of hospital-based facilities. The mean price paid by CalPERS fell by 17.6% (95% confidence interval, −24.9% to −9.6%) for knee procedures and by 17.0% (95% confidence interval, −29.3% to −2.5%) for shoulder procedures. The shift to reference-based benefits was not associated with a change in the rate of surgical complications. In the first two years after the implementation of reference-based benefits, CalPERS saved $2.3 million (13%) on these two orthopaedic procedures. Conclusions: Reference-based benefits increase consumer sensitivity to price differences between freestanding and hospital-based surgical facilities. Clinical Relevance: This study shows that the implementation of reference-based benefits does not result in a significant increase in measured complication rates for those subject to reference-based benefits. PMID:26378263

  8. A single-dose, crossover, placebo- and moxifloxacin-controlled study to assess the effects of neratinib (HKI-272) on cardiac repolarization in healthy adult subjects.

    PubMed

    Hug, Bruce; Abbas, Richat; Leister, Cathie; Burns, Jaime; Sonnichsen, Daryl

    2010-08-01

    Neratinib is an orally administered, small-molecule, irreversible pan-ErbB inhibitor in development for the treatment of ErbB2-positive breast cancer. This study assessed the effects of therapeutic and supratherapeutic neratinib concentrations on cardiac repolarization, in accordance with current regulatory guidance. This was a two-part study in healthy subjects. In part 1, subjects were randomized to receive placebo, 400 mg moxifloxacin, or 240 mg neratinib (therapeutic dose) following a high-fat meal. In part 2, after a washout period, subjects received placebo plus 400 mg ketoconazole or 240 mg neratinib plus ketoconazole (supratherapeutic dose). ANOVA was used to compare the baseline-adjusted QTc interval for neratinib with that of placebo (reference), and for neratinib plus ketoconazole with that of placebo plus ketoconazole (reference). Pharmacokinetic/pharmacodynamic analyses and categorical summaries of interval data were done. Assay sensitivity was evaluated by the effect of moxifloxacin on QTc compared with placebo. Sixty healthy subjects were enrolled in this study. The upper bounds of the 90% confidence interval for baseline-adjusted QTcN (population-specific corrected QT) were 450 milliseconds or change from baseline >30 milliseconds. Moxifloxacin produced a significant increase in QTcN compared with placebo (P < 0.05). Therapeutic and supratherapeutic plasma concentrations of neratinib do not prolong the QTc interval in healthy subjects. (c) 2010 AACR.

  9. Reference intervals: current status, recent developments and future considerations.

    PubMed

    Ozarda, Yesim

    2016-01-01

    Reliable and accurate reference intervals (RIs) for laboratory analyses are an integral part of the process of correct interpretation of clinical laboratory test results. RIs given in laboratory reports have an important role in aiding the clinician in interpreting test results in reference to values for healthy populations. Since the 1980s, the International Federation of Clinical Chemistry (IFCC) has been proactive in establishing recommendations to clarify the true significance of the term 'RIs, to select the appropriate reference population and statistically analyse the data. The C28-A3 guideline published by the Clinical and Laboratory Standards Institute (CLSI) and IFCC is still the most widely-used source of reference in this area. In recent years, protocols additional to the Guideline have been published by the IFCC, Committee on Reference Intervals and Decision Limits (C-RIDL), including all details of multicenter studies on RIs to meet the requirements in this area. Multicentric RIs studies are the most important development in the area of RIs. Recently, the C-RIDL has performed many multicentric studies to obtain common RIs. Confusion of RIs and clinical decision limits (CDLs) remains an issue and pediatric and geriatric age groups are a significant problem. For future studies of RIs, the genetic effect would seem to be the most challenging area. 
The aim of the review is to present the current theory and practice of RIs, with special emphasis given to multicenter RIs studies, RIs studies for pediatric and geriatric age groups, clinical decision limits and partitioning by genetic effects on RIs.

  10. Reference intervals: current status, recent developments and future considerations

    PubMed Central

    Ozarda, Yesim

    2016-01-01

    Reliable and accurate reference intervals (RIs) for laboratory analyses are an integral part of the process of correct interpretation of clinical laboratory test results. RIs given in laboratory reports have an important role in aiding the clinician in interpreting test results in reference to values for healthy populations. Since the 1980s, the International Federation of Clinical Chemistry (IFCC) has been proactive in establishing recommendations to clarify the true significance of the term ‘RIs, to select the appropriate reference population and statistically analyse the data. The C28-A3 guideline published by the Clinical and Laboratory Standards Institute (CLSI) and IFCC is still the most widely-used source of reference in this area. In recent years, protocols additional to the Guideline have been published by the IFCC, Committee on Reference Intervals and Decision Limits (C-RIDL), including all details of multicenter studies on RIs to meet the requirements in this area. Multicentric RIs studies are the most important development in the area of RIs. Recently, the C-RIDL has performed many multicentric studies to obtain common RIs. Confusion of RIs and clinical decision limits (CDLs) remains an issue and pediatric and geriatric age groups are a significant problem. For future studies of RIs, the genetic effect would seem to be the most challenging area.
The aim of the review is to present the current theory and practice of RIs, with special emphasis given to multicenter RIs studies, RIs studies for pediatric and geriatric age groups, clinical decision limits and partitioning by genetic effects on RIs. PMID:26981015

  11. Comparison of methods for the prediction of human clearance from hepatocyte intrinsic clearance for a set of reference compounds and an external evaluation set.

    PubMed

    Yamagata, Tetsuo; Zanelli, Ugo; Gallemann, Dieter; Perrin, Dominique; Dolgos, Hugues; Petersson, Carl

    2017-09-01

    1. We compared direct scaling, regression model equation and the so-called "Poulin et al." methods to scale clearance (CL) from in vitro intrinsic clearance (CL int ) measured in human hepatocytes using two sets of compounds. One reference set comprised of 20 compounds with known elimination pathways and one external evaluation set based on 17 compounds development in Merck (MS). 2. A 90% prospective confidence interval was calculated using the reference set. This interval was found relevant for the regression equation method. The three outliers identified were justified on the basis of their elimination mechanism. 3. The direct scaling method showed a systematic underestimation of clearance in both the reference and evaluation sets. The "Poulin et al." and the regression equation methods showed no obvious bias in either the reference or evaluation sets. 4. The regression model equation was slightly superior to the "Poulin et al." method in the reference set and showed a better absolute average fold error (AAFE) of value 1.3 compared to 1.6. A larger difference was observed in the evaluation set were the regression method and "Poulin et al." resulted in an AAFE of 1.7 and 2.6, respectively (removing the three compounds with known issues mentioned above). A similar pattern was observed for the correlation coefficient. Based on these data we suggest the regression equation method combined with a prospective confidence interval as the first choice for the extrapolation of human in vivo hepatic metabolic clearance from in vitro systems.

  12. A critical evaluation of the Beckman Coulter Access hsTnI: Analytical performance, reference interval and concordance.

    PubMed

    Pretorius, Carel J; Tate, Jillian R; Wilgen, Urs; Cullen, Louise; Ungerer, Jacobus P J

    2018-05-01

    We investigated the analytical performance, outlier rate, carryover and reference interval of the Beckman Coulter Access hsTnI in detail and compared it with historical and other commercial assays. We compared the imprecision, detection capability, analytical sensitivity, outlier rate and carryover against two previous Access AccuTnI assay versions. We established the reference interval with stored samples from a previous study and compared the concordances and variances with the Access AccuTnI+3 as well as with two commercial assays. The Access hsTnI had excellent analytical sensitivity with the calibration slope 5.6 times steeper than the Access AccuTnI+3. The detection capability was markedly improved with the SD of the blank 0.18-0.20 ng/L, LoB 0.29-0.33 ng/L and LoD 0.58-0.69 ng/L. All the reference interval samples had a result above the LoB value. At a mean concentration of 2.83 ng/L the SD was 0.28 ng/L (CV 9.8%). Carryover (0.005%) and outlier (0.046%) rates were similar to the Access AccuTnI+3. The combined male and female 99th percentile reference interval was 18.2 ng/L (90% CI 13.2-21.1 ng/L). Concordance amongst the assays was poor with only 16.7%, 19.6% and 15.2% of samples identified by all 4 assays as above the 99th, 97.5th and 95th percentiles. Analytical imprecision was a minor contributor to the observed variances between assays. The Beckman Coulter Access hsTnI assay has excellent analytical sensitivity and precision characteristics close to zero. This allows cTnI measurement in all healthy individuals and the capability to identify numerically small differences between serial samples as statistically significant. Concordance in healthy individuals remains poor amongst assays. Crown Copyright © 2018. Published by Elsevier Inc. All rights reserved.

  13. A bioequivalence study of gliclazide based on quantification by high-performance liquid chromatography coupled with electrospray tandem mass spectrometry.

    PubMed

    Mendes, G D; Moreira, L D; Pereira, A dos S; Borges, A; Yui, F; Mendes, F D; de Nucci, G

    2007-03-01

    The aim of this study was to evaluate, in human volunteers, the performance of one gliclazide tablet formulation (gliclazide 80 mg tablet from EMS Indústria Farmacêutica Ltda.) against two reference gliclazide tablet formulations (Diamicron 80 mg tablet from Servier do Brazil Ltda. and Diamicron 80 mg tablet from Servier (Ireland) Industries Limited). The study had an open, randomized, three-period crossover design with a one-week washout interval between doses. The samples were obtained over a 48-h interval after each oral administration of gliclazide. The samples were extracted from plasma using diethylether : hexane (80 : 20, v/v) and the extracts were analyzed by high-performance liquid chromatography coupled with electrospray tandem mass spectrometry (HPLC-MS/ MS). Chromatography was performed isocratically using a Jones Chromatography Genesis C8 120A 4u. The method had a chromatographic run-time of 2.5 min and a calibration curve of the range of 0.02- 10 microg x ml(-1) (r(2) > 0.9993). The limit of quantification was 0.02 microg x ml(-1). The geometric mean and 90% confidence intervals (CI) for the Gliclazide/Diamicron (Ireland) ratio were 588.68% (90% CI= 491.16, 705.58%) for AUClast, 423.50% (90% CI = 338.25, 530.23%) for AUCinf, and 1395.77% (90% CI= 1116.62, 1744.72%) for Cmax. The geometric mean and 90% confidence intervals (CI) for the Gliclazide/Diamicron (Brazil) ratio were 249.16% (90% CI = 207.96, 298.54%) for AUCiast, 249.16% (90% CI = 207.96 - 298.54%) for AUCinf, and 188.04% (90% CI - 151.72, 233.05%) for Cmax. Since the 90% CI for Cmax, AUClast and AUC(0-infinity) ratios were all outside the 125% interval proposed by the US Food and Drug Administration, we concluded that the gliclazide test formulation were not bioequivalent to either reference formulation. Interestingly, the pharmacokinetic parameters such as Cmax, AUClast of both reference formulations are compatible with neither the literature nor the profile of an immediate release formulation. In addition, both reference formulations were not bioequivalent in themselves, indicating significant differences in reference product formulation.

  14. Measurement of cardiac troponin I in healthy lactating dairy cows using a point of care analyzer (i-STAT-1).

    PubMed

    Labonté, Josiane; Roy, Jean-Philippe; Dubuc, Jocelyn; Buczinski, Sébastien

    2015-06-01

    Cardiac troponin I (cTnI) has been shown to be an accurate predictor of myocardial injury in cattle. The point-of-care i-STAT 1 immunoassay can be used to quantify blood cTnI in cattle. However, the cTnI reference interval in whole blood of healthy early lactating dairy cows remains unknown. To determine a blood cTnI reference interval in healthy early lactating Holstein dairy cows using the analyzer i-STAT 1. Forty healthy lactating dairy Holstein cows (0-60 days in milk) were conveniently selected from four commercial dairy farms. Each selected cow was examined by a veterinarian and transthoracic echocardiography was performed. A cow-side blood cTnI dosage was measured at the same time. A bootstrap statistical analysis method using unrestricted resampling was used to determine a reference interval for blood cTnI values. Forty healthy cows were recruited in the study. Median blood cTnI was 0.02 ng/mL (minimum: 0.00, maximum: 0.05). Based on the bootstrap analysis method with 40 cases, the 95th percentile of cTnI values in healthy cows was 0.036 ng/mL (90% CI: 0.02-0.05 ng/mL). A reference interval for blood cTnI values in healthy lactating cows was determined. Further research is needed to determine whether cTnI blood values could be used to diagnose and provide a prognosis for cardiac and noncardiac diseases in lactating dairy cows. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Differences in levels of albumin, ALT, AST, γ-GT and creatinine in frail, moderately healthy and healthy elderly individuals.

    PubMed

    Edvardsson, Maria; Sund-Levander, Märtha; Milberg, Anna; Wressle, Ewa; Marcusson, Jan; Grodzinsky, Ewa

    2018-02-23

    Reference intervals are widely used as decision tools, providing the physician with information about whether the analyte values indicate ongoing disease process. Reference intervals are generally based on individuals without diagnosed diseases or use of medication, which often excludes elderly. The aim of the study was to assess levels of albumin, alanine aminotransferase (ALT), aspartate aminotransferase (AST), creatinine and γ-glutamyl transferase (γ-GT) in frail, moderately healthy and healthy elderly indivuduals. Blood samples were collected from individuals >80 years old, nursing home residents, in the Elderly in Linköping Screening Assessment and Nordic Reference Interval Project, a total of 569 individuals. They were divided into three cohorts: frail, moderately healthy and healthy, depending on cognitive and physical function. Albumin, ALT, AST, creatinine and γ-GT were analyzed using routine methods. Linear regression predicted factors for 34% of the variance in albumin were activities of daily living (ADL), gender, stroke and cancer. ADLs, gender and weight explained 15% of changes in ALT. For AST levels, ADLs, cancer and analgesics explained 5% of changes. Kidney disease, gender, Mini Mental State Examination (MMSE) and chronic obstructive pulmonary disease explained 25% of the variation in creatinine levels and MMSE explained three per cent of γ-GT variation. Because a group of people are at the same age, they should not be assessed the same way. To interpret results of laboratory tests in elderly is a complex task, where reference intervals are one part, but far from the only one, to take into consideration.

  16. PLASMA PROTEIN ELECTROPHORESIS AND SELECT ACUTE PHASE PROTEINS IN HEALTHY BONNETHEAD SHARKS (SPHYRNA TIBURO) UNDER MANAGED CARE.

    PubMed

    Hyatt, Michael W; Field, Cara L; Clauss, Tonya M; Arheart, Kristopher L; Cray, Carolyn

    2016-12-01

    Preventative health care of elasmobranchs is an important but understudied field of aquatic veterinary medicine. Evaluation of inflammation through the acute phase response is a valuable tool in health assessments. To better assess the health of bonnethead sharks ( Sphyrna tiburo ) under managed care, normal reference intervals of protein electrophoresis (EPH) and the acute phase proteins, C-reactive protein (CRP) and haptoglobin (HP), were established. Blood was collected from wild caught, captive raised bonnethead sharks housed at public aquaria. Lithium heparinized plasma was either submitted fresh or stored at -80°C prior to submission. Electrophoresis identified protein fractions with migration characteristics similar to other animals with albumin, α-1 globulin, α-2 globulin, β globulin, and γ globulin. These fractions were classified as fractions 1-5 as fractional contents are unknown in this species. Commercial reagents for CRP and HP were validated for use in bonnethead sharks. Reference intervals were established using the robust method recommended by the American Society for Veterinary Clinical Pathology for the calculation of 90% reference intervals. Once established, the diagnostic and clinical applicability of these reference intervals was used to assess blood from individuals with known infectious diseases that resulted in systemic inflammation and eventual death. Unhealthy bonnethead sharks had significantly decreased fraction 2, fraction 3, and fraction 3:4 ratio and significantly increased fraction 5, CRP, and HP. These findings advance our understanding of elasmobranch acute phase inflammatory response and health and aid clinicians in the diagnosis of inflammatory disease in bonnethead sharks.

  17. Immediate Vascular Imaging Needed for Efficient Triage of Patients With Acute Ischemic Stroke Initially Admitted to Nonthrombectomy Centers.

    PubMed

    Boulouis, Gregoire; Siddiqui, Khawja-Ahmeruddin; Lauer, Arne; Charidimou, Andreas; Regenhardt, Robert W; Viswanathan, Anand; Leslie-Mazwi, Thabele M; Rost, Natalia; Schwamm, Lee H

    2017-08-01

    Current guidelines for endovascular thrombectomy (EVT) used to select patients for transfer to thrombectomy-capable stroke centers (TSC) may result in unnecessary transfers. We sought to determine the impact of simulated baseline vascular imaging on reducing unnecessary transfers and clinical-imaging factors associated with receiving EVT after transfer. We identified patients with stroke transferred for EVT from 30 referring hospitals between 2010 and 2016 who had a referring hospitals brain computed tomography and repeat imaging on TSC arrival available for review. Initial Alberta Stroke Program Early CT scores and TSC vascular occlusion level were assessed. The main outcome variable was receiving EVT at TSC. Models were simulated to derive optimal triaging parameters for EVT. A total of 508 patients were included in the analysis (mean age, 69±14 years; 42% women). Application at referring hospitals of current guidelines for EVT yielded sensitivity of 92% (95% confidence interval, 0.84-0.96) and specificity of 53% (95% confidence interval, 0.48-0.57) for receiving EVT at TSC. Repeated simulations identified optimal selection criteria for transfer as National Institute of Health Stroke Scale >8 plus baseline vascular imaging (sensitivity=91%; 95% confidence interval, 0.83-0.95; and specificity=80%; 95% confidence interval, 0.75-0.83). Our findings provide quantitative estimates of the claim that implementing vascular imaging at the referring hospitals would result in significantly fewer futile transfers for EVT and a data-driven framework to inform transfer policies. © 2017 American Heart Association, Inc.

  18. Assessment of cardiac time intervals using high temporal resolution real-time spiral phase contrast with UNFOLDed-SENSE.

    PubMed

    Kowalik, Grzegorz T; Knight, Daniel S; Steeden, Jennifer A; Tann, Oliver; Odille, Freddy; Atkinson, David; Taylor, Andrew; Muthurangu, Vivek

    2015-02-01

    To develop a real-time phase contrast MR sequence with high enough temporal resolution to assess cardiac time intervals. The sequence utilized spiral trajectories with an acquisition strategy that allowed a combination of temporal encoding (Unaliasing by fourier-encoding the overlaps using the temporal dimension; UNFOLD) and parallel imaging (Sensitivity encoding; SENSE) to be used (UNFOLDed-SENSE). An in silico experiment was performed to determine the optimum UNFOLD filter. In vitro experiments were carried out to validate the accuracy of time intervals calculation and peak mean velocity quantification. In addition, 15 healthy volunteers were imaged with the new sequence, and cardiac time intervals were compared to reference standard Doppler echocardiography measures. For comparison, in silico, in vitro, and in vivo experiments were also carried out using sliding window reconstructions. The in vitro experiments demonstrated good agreement between real-time spiral UNFOLDed-SENSE phase contrast MR and the reference standard measurements of velocity and time intervals. The protocol was successfully performed in all volunteers. Subsequent measurement of time intervals produced values in keeping with literature values and good agreement with the gold standard echocardiography. Importantly, the proposed UNFOLDed-SENSE sequence outperformed the sliding window reconstructions. Cardiac time intervals can be successfully assessed with UNFOLDed-SENSE real-time spiral phase contrast. Real-time MR assessment of cardiac time intervals may be beneficial in assessment of patients with cardiac conditions such as diastolic dysfunction. © 2014 Wiley Periodicals, Inc.

  19. Computing Relative Free Energies of Solvation Using Single Reference Thermodynamic Integration Augmented with Hamiltonian Replica Exchange

    DTIC Science & Technology

    2010-10-21

    paper assess the reversible works needed to alchemi - cally change each molecule to the benzene core reference state. To automate the alchemical...the alchemi - cal free energies or reversible works, the TI procedure split the interval from the real state of the molecule at λ ) 0 to the reference

  20. Blood and Plasma Biochemistry Reference Intervals for Wild Juvenile American Alligators ( Alligator mississippiensis ).

    PubMed

    Hamilton, Matthew T; Kupar, Caitlin A; Kelley, Meghan D; Finger, John W; Tuberville, Tracey D

    2016-07-01

    : American alligators ( Alligator mississippiensis ) are one of the most studied crocodilian species in the world, yet blood and plasma biochemistry information is limited for juvenile alligators in their northern range, where individuals may be exposed to extreme abiotic and biotic stressors. We collected blood samples over a 2-yr period from 37 juvenile alligators in May, June, and July to establish reference intervals for 22 blood and plasma analytes. We observed no effect of either sex or blood collection time on any analyte investigated. However, our results indicate a significant correlation between a calculated body condition index and aspartate aminotransferase and creatine kinase. Glucose, total protein, and potassium varied significantly between sampling sessions. In addition, glucose and potassium were highly correlated between the two point-of-care devices used, although they were significantly lower with the i-STAT 1 CG8+ cartridge than with the Vetscan VS2 Avian/Reptile Rotor. The reference intervals presented herein should provide baseline data for evaluating wild juvenile alligators in the northern portion of their range.

  1. Association between GFR Estimated by Multiple Methods at Dialysis Commencement and Patient Survival

    PubMed Central

    Wong, Muh Geot; Pollock, Carol A.; Cooper, Bruce A.; Branley, Pauline; Collins, John F.; Craig, Jonathan C.; Kesselhut, Joan; Luxton, Grant; Pilmore, Andrew; Harris, David C.

    2014-01-01

    Summary Background and objectives The Initiating Dialysis Early and Late study showed that planned early or late initiation of dialysis, based on the Cockcroft and Gault estimation of GFR, was associated with identical clinical outcomes. This study examined the association of all-cause mortality with estimated GFR at dialysis commencement, which was determined using multiple formulas. Design, setting, participants, & measurements Initiating Dialysis Early and Late trial participants were stratified into tertiles according to the estimated GFR measured by Cockcroft and Gault, Modification of Diet in Renal Disease, or Chronic Kidney Disease-Epidemiology Collaboration formula at dialysis commencement. Patient survival was determined using multivariable Cox proportional hazards model regression. Results Only Initiating Dialysis Early and Late trial participants who commenced on dialysis were included in this study (n=768). A total of 275 patients died during the study. After adjustment for age, sex, racial origin, body mass index, diabetes, and cardiovascular disease, no significant differences in survival were observed between estimated GFR tertiles determined by Cockcroft and Gault (lowest tertile adjusted hazard ratio, 1.11; 95% confidence interval, 0.82 to 1.49; middle tertile hazard ratio, 1.29; 95% confidence interval, 0.96 to 1.74; highest tertile reference), Modification of Diet in Renal Disease (lowest tertile hazard ratio, 0.88; 95% confidence interval, 0.63 to 1.24; middle tertile hazard ratio, 1.20; 95% confidence interval, 0.90 to 1.61; highest tertile reference), and Chronic Kidney Disease-Epidemiology Collaboration equations (lowest tertile hazard ratio, 0.93; 95% confidence interval, 0.67 to 1.27; middle tertile hazard ratio, 1.15; 95% confidence interval, 0.86 to 1.54; highest tertile reference). Conclusion Estimated GFR at dialysis commencement was not significantly associated with patient survival, regardless of the formula used. However, a clinically important association cannot be excluded, because observed confidence intervals were wide. PMID:24178976

  2. Use of precision time and time interval (PTTI)

    NASA Technical Reports Server (NTRS)

    Taylor, J. D.

    1974-01-01

    A review of range time synchronization methods are discussed as an important aspect of range operations. The overall capabilities of various missile ranges to determine precise time of day by synchronizing to available references and applying this time point to instrumentation for time interval measurements are described.

  3. Comparison of methods used to diagnose generalized inflammatory disease in manatees (Trichechus manatus latirostris)

    USGS Publications Warehouse

    Harr, K.E.; Harvey, J.W.; Bonde, R.K.; Murphy, D.; Lowe, Mark; Menchaca, M.; Haubold, E.M.; Francis-Floyd, R.

    2006-01-01

    Manatees (Trichechus manatus latirostris) are afflicted with inflammatory and infectious disease secondary to human interaction, such as boat strike and entanglement, as well as “cold stress syndrome” and pneumonia. White-blood-cell count and fever, primary indicators of systemic inflammation in most species, are insensitive in diagnosing inflammatory disease in manatees. Acute phase-response proteins, such as haptoglobin and serum amyloid A, have proven to be sensitive measures of inflammation/infection in domestic large animal species. This study assessed diagnosis of generalized inflammatory disease by different methods including total white-blood-cell count, albumin: globulin ratio, gel electrophoresis analysis, C-reactive protein, alpha1 acid glycoprotein, haptoglobin, fibrinogen, and serum amyloid A. Samples were collected from 71 apparently healthy and 27 diseased animals during diagnostic medical examination. Serum amyloid A, measured by ELISA, followed by albumin:globulin ratio, measured by plasma gel electrophoresis, were most sensitive in diagnosing inflammatory disease, with diagnostic sensitivity and specificity of approximately 90%. The reference interval for serum amyloid A is <10–50 μg/ml with an equivocal interval of 51–70 μg/ml. The reference interval for albumin:globulin ratio by plasma gel electrophoresis is 0.7–1.1. Albumin: globulin ratio, calculated using biochemical techniques, was not accurate due to overestimation of albumin by bromcresol green dye-binding methodology. Albumin:globulin ratio, measured by serum gel electrophoresis, has a low sensitivity of 15% due to the lack of fibrinogen in the sample. Haptoglobin, measured by hemoglobin titration, had a reference interval of 0.4–2.4 mg/ml, a diagnostic sensitivity of 60%, and a diagnostic specificity of 93%. The haptoglobin assay is significantly affected by hemolysis. Fibrinogen, measured by heat precipitation, has a reference interval of 100–400 mg/dl, a diagnostic sensitivity of 40%, and a diagnostic specificity of 95%.

  4. Comparison of methods used to diagnose generalized inflammatory disease in manatees (Trichechus manatus latirostris).

    PubMed

    Harr, Kendal; Harvey, John; Bonde, Robert; Murphy, David; Lowe, Mark; Menchaca, Maya; Haubold, Elsa; Francis-Floyd, Ruth

    2006-06-01

    Manatees (Trichechus manatus latirostris) are afflicted with inflammatory and infectious disease secondary to human interaction, such as boat strike and entanglement, as well as "cold stress syndrome" and pneumonia. White-blood-cell count and fever, primary indicators of systemic inflammation in most species, are insensitive in diagnosing inflammatory disease in manatees. Acute phase-response proteins, such as haptoglobin and serum amyloid A, have proven to be sensitive measures of inflammation/infection in domestic large animal species. This study assessed diagnosis of generalized inflammatory disease by different methods including total white-blood-cell count, albumin: globulin ratio, gel electrophoresis analysis, C-reactive protein, alpha, acid glycoprotein, haptoglobin, fibrinogen, and serum amyloid A. Samples were collected from 71 apparently healthy and 27 diseased animals during diagnostic medical examination. Serum amyloid A, measured by ELISA, followed by albumin:globulin ratio, measured by plasma gel electrophoresis, were most sensitive in diagnosing inflammatory disease, with diagnostic sensitivity and specificity of approximately 90%. The reference interval for serum amyloid A is <10-50 microg/ml with an equivocal interval of 51-70 microg/ml. The reference interval for albumin:globulin ratio by plasma gel electrophoresis is 0.7-1.1. Albumin: globulin ratio, calculated using biochemical techniques, was not accurate due to overestimation of albumin by bromcresol green dye-binding methodology. Albumin:globulin ratio, measured by serum gel electrophoresis, has a low sensitivity of 15% due to the lack of fibrinogen in the sample. Haptoglobin, measured by hemoglobin titration, had a reference interval of 0.4-2.4 mg/ml, a diagnostic sensitivity of 60%, and a diagnostic specificity of 93%. The haptoglobin assay is significantly affected by hemolysis. Fibrinogen, measured by heat precipitation, has a reference interval of 100-400 mg/dl, a diagnostic sensitivity of 40%, and a diagnostic specificity of 95%.

  5. Spatial Updating According to a Fixed Reference Direction of a Briefly Viewed Layout

    ERIC Educational Resources Information Center

    Zhang, Hui; Mou, Weimin; McNamara, Timothy P.

    2011-01-01

    Three experiments examined the role of reference directions in spatial updating. Participants briefly viewed an array of five objects. A non-egocentric reference direction was primed by placing a stick under two objects in the array at the time of learning. After a short interval, participants detected which object had been moved at a novel view…

  6. Novel lipoprotein density profiling in healthy dogs of various breeds, healthy miniature schnauzers, and miniature schnauzers with hyperlipidemia

    PubMed Central

    2013-01-01

    Background Despite the importance of abnormalities in lipoprotein metabolism in clinical canine medicine, the fact that most previously used methods for lipoprotein profiling are rather laborious and time-consuming has been a major obstacle to the wide clinical application and use of lipoprotein profiling in this species. The aim of the present study was to assess the feasibility of a continuous lipoprotein density profile (CLPDP) generated within a bismuth sodium ethylenediaminetetraacetic acid (NaBiEDTA) density gradient to characterize and compare the lipoprotein profiles of healthy dogs of various breeds, healthy Miniature Schnauzers, and Miniature Schnauzers with primary hypertriacylglycerolemia. A total of 35 healthy dogs of various breeds with serum triacylglycerol (TAG) and cholesterol concentrations within their respective reference intervals were selected for use as a reference population. Thirty-one Miniature Schnauzers with serum TAG and cholesterol concentrations within their respective reference intervals and 31 Miniature Schnauzers with hypertriacylglyceridemia were also included in the study. Results The results suggest that CLPDP using NaBiEDTA provides unique diagnostic information in addition to measurements of serum TAG and cholesterol concentrations and that it is a useful screening method for dogs with suspected lipoprotein metabolism disorders. Using the detailed and continuous density distribution information provided by the CLPDP, important differences in lipoprotein profiles can be detected even among dogs that have serum TAG and cholesterol concentrations within the reference interval. Miniature Schnauzers with serum TAG and cholesterol concentrations within the reference interval had significantly different lipoprotein profiles than dogs of various other breeds. In addition, it was further established that specific lipoprotein fractions are associated with hypertriacylglyceridemia in Miniature Schnauzers. Conclusions The results of the present study suggest that density gradient ultracentrifugation using NaBiEDTA is a useful screening method for the study of lipoprotein profiles in dogs. Therefore, this method could potentially be used for diagnostic purposes for the separation of dogs suspected of having lipoprotein abnormalities from healthy dogs. PMID:23497598

  7. A global multicenter study on reference values: 1. Assessment of methods for derivation and comparison of reference intervals.

    PubMed

    Ichihara, Kiyoshi; Ozarda, Yesim; Barth, Julian H; Klee, George; Qiu, Ling; Erasmus, Rajiv; Borai, Anwar; Evgina, Svetlana; Ashavaid, Tester; Khan, Dilshad; Schreier, Laura; Rolle, Reynan; Shimizu, Yoshihisa; Kimura, Shogo; Kawano, Reo; Armbruster, David; Mori, Kazuo; Yadav, Binod K

    2017-04-01

    The IFCC Committee on Reference Intervals and Decision Limits coordinated a global multicenter study on reference values (RVs) to explore rational and harmonizable procedures for derivation of reference intervals (RIs) and investigate the feasibility of sharing RIs through evaluation of sources of variation of RVs on a global scale. For the common protocol, rather lenient criteria for reference individuals were adopted to facilitate harmonized recruitment with planned use of the latent abnormal values exclusion (LAVE) method. As of July 2015, 12 countries had completed their study with total recruitment of 13,386 healthy adults. 25 analytes were measured chemically and 25 immunologically. A serum panel with assigned values was measured by all laboratories. RIs were derived by parametric and nonparametric methods. The effect of LAVE methods is prominent in analytes which reflect nutritional status, inflammation and muscular exertion, indicating that inappropriate results are frequent in any country. The validity of the parametric method was confirmed by the presence of analyte-specific distribution patterns and successful Gaussian transformation using the modified Box-Cox formula in all countries. After successful alignment of RVs based on the panel test results, nearly half the analytes showed variable degrees of between-country differences. This finding, however, requires confirmation after adjusting for BMI and other sources of variation. The results are reported in the second part of this paper. The collaborative study enabled us to evaluate rational methods for deriving RIs and comparing the RVs based on real-world datasets obtained in a harmonized manner. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  8. Analyses of laboratory data and establishment of reference values and intervals for healthy elderly people.

    PubMed

    Kubota, K; Kadomura, T; Ohta, K; Koyama, K; Okuda, H; Kobayashi, M; Ishii, C; Fujiwara, Y; Nishiora, T; Ohmae, Y; Ohmae, T; Kitajima, M

    2012-04-01

    Protein-energy malnutrition is a common disorder in the elderly. Although serum albumin is commonly used as a nutritional marker, data is lacking on serum albumin levels in the elderly. The purpose of this study was to determine whether serum albumin levels decrease with advancing age and to establish reference value and interval of laboratory data for elderly people (75 years and over). Blood samples from 13821 healthy people, 42064 outpatients, and 15959 inpatients were collected during 2008. Blood from 127 of our nutrition support team (NST) patients was also collected during August 2006 and May 2009, and analyzed. Serum albumin, hemoglobin, total cholesterol levels and lymphocyte count were determined. We analyzed the change in each parameter in accordance with age, compared the data for elderly people with younger people, and established new reference values. Clinical outcomes were examined depending on the improved reference values. Albumin was lower in older persons than in younger persons. The estimated reference value and interval were 42 (48-36) g/l in older persons and was much lower in NST patients. Hemoglobin was decreased while cholesterol and lymphocyte count were not changed in older persons: all were markedly decreased in NST patients. Terms of hospital stay were significantly longer and mortality rates were significantly higher in older persons, comparing from above to below using a new reference value of albumin (36 g/l). The serum albumin level decreases with advancing age, but it was maintained to some extent in healthy older people. Serum albumin levels related to the clinical outcome. Hemoglobin and cholesterol levels and lymphocyte count were all lower in NST patients. These measurements may be valuable markers of nutritional status and can help in guiding the need for nutritional support.

  9. Optimized angiotensin-converting enzyme activity assay for the accurate diagnosis of sarcoidosis.

    PubMed

    Csongrádi, Alexandra; Enyedi, Attila; Takács, István; Végh, Tamás; Mányiné, Ivetta S; Pólik, Zsófia; Altorjay, István Tibor; Balla, József; Balla, György; Édes, István; Kappelmayer, János; Tóth, Attila; Papp, Zoltán; Fagyas, Miklós

    2018-06-27

    Serum angiotensin-converting enzyme (ACE) activity determination can aid the early diagnosis of sarcoidosis. We aimed to optimize a fluorescent kinetic assay for ACE activity by screening the confounding effects of endogenous ACE inhibitors and interfering factors. Genotype-dependent and genotype-independent reference values of ACE activity were established, and their diagnostic accuracies were validated in a clinical study. Internally quenched fluorescent substrate, Abz-FRK(Dnp)P-OH was used for ACE-activity measurements. A total of 201 healthy individuals and 59 presumably sarcoidotic patients were enrolled into this study. ACE activity and insertion/deletion (I/D) genotype of the ACE gene were determined. Here we report that serum samples should be diluted at least 35-fold to eliminate the endogenous inhibitor effect of albumin. No significant interferences were detected: up to a triglyceride concentration of 16 mM, a hemoglobin concentration of 0.71 g/L and a bilirubin concentration of 150 μM. Genotype-dependent reference intervals were considered as 3.76-11.25 U/L, 5.22-11.59 U/L, 7.19-14.84 U/L for II, ID and DD genotypes, respectively. I/D genotype-independent reference interval was established as 4.85-13.79 U/L. An ACE activity value was considered positive for sarcoidosis when it exceeded the upper limit of the reference interval. The optimized assay with genotype-dependent reference ranges resulted in 42.5% sensitivity, 100% specificity, 100% positive predictive value and 32.4% negative predictive value in the clinical study, whereas the genotype-independent reference range proved to have inferior diagnostic efficiency. An optimized fluorescent kinetic assay of serum ACE activity combined with ACE I/D genotype determination is an alternative to invasive biopsy for confirming the diagnosis of sarcoidosis in a significant percentage of patients.

  10. IBM system/360 assembly language interval arithmetic software

    NASA Technical Reports Server (NTRS)

    Phillips, E. J.

    1972-01-01

    Computer software designed to perform interval arithmetic is described. An interval is defined as the set of all real numbers between two given numbers including or excluding one or both endpoints. Interval arithmetic consists of the various elementary arithmetic operations defined on the set of all intervals, such as interval addition, subtraction, union, etc. One of the main applications of interval arithmetic is in the area of error analysis of computer calculations. For example, it has been used sucessfully to compute bounds on sounding errors in the solution of linear algebraic systems, error bounds in numerical solutions of ordinary differential equations, as well as integral equations and boundary value problems. The described software enables users to implement algorithms of the type described in references efficiently on the IBM 360 system.

  11. Reassessment of the Access Testosterone chemiluminescence assay and comparison with LC-MS method.

    PubMed

    Dittadi, Ruggero; Matteucci, Mara; Meneghetti, Elisa; Ndreu, Rudina

    2018-03-01

    To reassess the imprecision and Limit of Quantitation, to evaluate the cross-reaction with dehydroepiandrosterone-sulfate (DHEAS), the accuracy toward liquid chromatography-mass spectrometry (LC-MS) and the reference interval of the Access Testosterone method, performed by DxI immunoassay platform (Beckman Coulter). Imprecision was evaluated testing six pool samples assayed in 20 different run using two reagents lots. The cross-reaction with DHEAS was studied both by a displacement curve and by spiking DHEAS standard in two serum samples with known amount of testosterone. The comparison with LC-MS was evaluated by Passing-Bablock analysis in 21 routine serum samples and 19 control samples from an External Quality Assurance (EQA) scheme. The reference interval was verified by an indirect estimation on 2445 male and 2838 female outpatients. The imprecision study showed a coefficient of variation (CV) between 2.7% and 34.7% for serum pools from 16.3 and 0.27 nmol/L. The value of Limit of Quantitation at 20% CV was 0.53 nmol/L. The DHEAS showed a cross-reaction of 0.0074%. A comparison with LC-MS showed a trend toward a slight underestimation of immunoassay vs LC-MS (Passing-Bablock equations: DxI=-0.24+0.906 LCMS in serum samples and DxI=-0.299+0.981 LCMS in EQA samples). The verification of reference interval showed a 2.5th-97.5th percentile distribution of 6.6-24.3 nmol/L for male over 14 years and <0.5-2.78 nmol/L for female subjects, in accord with the reference intervals reported by the manufacturer. The Access Testosterone method could be considered an adequately reliable tool for the testosterone measurement. © 2017 Wiley Periodicals, Inc.

  12. Performance evaluation of the Roche Tina-quant Cystatin C assay and reference interval for cystatin C in healthy blood donors.

    PubMed

    Erlandsen, Erland J; Randers, Else

    2010-07-01

    To evaluate the performance of the Roche Diagnostics Tina-quant Cystatin C particle enhanced immuno turbidimetric assay for the measurement of plasma and serum cystatin C, and to establish reference intervals for cystatin C in healthy blood donors. The cystatin C measurements were performed on the Roche Modular Analytics P automated clinical chemistry analyzer. The cystatin C assay was linear in the measuring range 0.40-7.00 mg/L. Within-run CVs < or = 2.0%, between-run CVs < or = 4.2%, and total CVs < or = 5.5% in plasma pools and in commercial cystatin C control materials (range 1.0-4.7 mg/L). Recovery was 99.4-109.3%. No interference was detected from haemoglobin < 0.9 mmol/L, bilirubin < 330 micromol/L and Intralipid < 20 g/L. Measurement of cystatin C in Li-heparin plasma did not differ significantly from cystatin C measured in serum. Forty patient samples run on the Modular Analytics P (y) were compared to the Siemens Cystatin C assay on the BN II (x): y = 0.817x + 0.270, Sy.x = 0.168 (Deming regression). The non-parametric reference interval for cystatin C was calculated to be 0.41-0.91 mg/L in females (n = 86), and 0.43-0.94 mg/L in males (n = 76). The Mann-Whitney U test showed a significant difference between the two genders (p = 0.015), but the difference was without clinical relevance. A common reference interval for both genders (n = 162) was calculated to be 0.41-0.92 mg/L. The performance of the Tina-quant Cystatin C assay was acceptable for clinical use.

  13. Establishment of reference intervals for complete blood count parameters during normal pregnancy in Beijing.

    PubMed

    Li, Aiwei; Yang, Shuo; Zhang, Jie; Qiao, Rui

    2017-11-01

    To observe the changes of complete blood count (CBC) parameters during pregnancy and establish appropriate reference intervals for healthy pregnant women. Healthy pregnant women took the blood tests at all trimesters. All blood samples were processed on Sysmex XE-2100. The following CBC parameters were analyzed: red blood cell count (RBC), hemoglobin (Hb), hematocrit (Hct), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), red blood cell distribution width (RDW), platelet count (PLT), mean platelet volume (MPV), platelet distribution width (PDW), white blood cell count (WBC), and leukocyte differential count. Reference intervals were established using the 2.5th and 97.5th percentile of the distribution. Complete blood count parameters showed dynamic changes during trimesters. RBC, Hb, Hct declined at trimester 1, reaching their lowest point at trimester 2, and began to rise again at trimester 3. WBC, neutrophil count (Neut), monocyte count (MONO), RDW, and PDW went up from trimester 1 to trimester 3. On the contrary, MCHC, lymphocyte count (LYMPH), PLT, and MPV gradually descended during pregnancy. There were statistical significances in all CBC parameters between pregnant women and normal women, regardless of the trimesters (P<.001). The median obtained were (normal vs pregnancy) as follows: RBC 4.50 vs 3.94×10 12 /L, Hb 137 vs 120 g/L, WBC 5.71 vs 9.06×10 9 /L, LYMPH% 32.2 vs 18.0, Neut% 58.7 vs 75.0, and PLT 251 vs 202×10 9 /L. The changes of CBC parameters during pregnancy are described, and reference intervals for Beijing pregnant women are demonstrated in this study. © 2017 Wiley Periodicals, Inc.

  14. Development of Salivary Cortisol Circadian Rhythm and Reference Intervals in Full-Term Infants.

    PubMed

    Ivars, Katrin; Nelson, Nina; Theodorsson, Annette; Theodorsson, Elvar; Ström, Jakob O; Mörelius, Evalotte

    2015-01-01

    Cortisol concentrations in plasma display a circadian rhythm in adults and children older than one year. Earlier studies report divergent results regarding when cortisol circadian rhythm is established. The present study aims to investigate at what age infants develop a circadian rhythm, as well as the possible influences of behavioral regularity and daily life trauma on when the rhythm is established. Furthermore, we determine age-related reference intervals for cortisol concentrations in saliva during the first year of life. 130 healthy full-term infants were included in a prospective, longitudinal study with saliva sampling on two consecutive days, in the morning (07:30-09:30), noon (10:00-12:00) and evening (19:30-21:30), each month from birth until the infant was twelve months old. Information about development of behavioral regularity and potential exposure to trauma was obtained from the parents through the Baby Behavior Questionnaire and the Life Incidence of Traumatic Events checklist. A significant group-level circadian rhythm of salivary cortisol secretion was established at one month, and remained throughout the first year of life, although there was considerable individual variability. No correlation was found between development of cortisol circadian rhythm and the results from either the Baby Behavior Questionnaire or the Life Incidence of Traumatic Events checklist. The study presents salivary cortisol reference intervals for infants during the first twelve months of life. Cortisol circadian rhythm in infants is already established by one month of age, earlier than previous studies have shown. The current study also provides first year age-related reference intervals for salivary cortisol levels in healthy, full-term infants.

  15. Verification of Abbott 25-OH-vitamin D assay on the architect system.

    PubMed

    Hutchinson, Katrina; Healy, Martin; Crowley, Vivion; Louw, Michael; Rochev, Yury

    2017-04-01

    Analytical and clinical verification of both old and new generations of the Abbott total 25-hydroxyvitamin D (25OHD) assays, and an examination of reference Intervals. Determination of between-run precision, and Deming comparison between patient sample results for 25OHD on the Abbott Architect, DiaSorin Liaison and AB SCIEX API 4000 (LC-MS/MS). Establishment of uncertainty of measurement for 25OHD Architect methods using old and new generations of the reagents, and estimation of reference interval in healthy Irish population. For between-run precision the manufacturer claims 2.8% coefficients of variation (CVs) of 2.8% and 4.6% for their high and low controls, respectively. Our instrument showed CVs between 4% and 6.2% for all levels of the controls on both generations of the Abbott reagents. The between-run uncertainties were 0.28 and 0.36, with expanded uncertainties 0.87 and 0.98 for the old and the new generations of reagent, respectively. The difference between all methods used for patients' samples was within total allowable error, and the instruments produced clinically equivalent results. The results covered the medical decision points of 30, 40, 50 and 125 nmol/L. The reference interval for total 25OHD in our healthy Irish subjects was lower than recommended levels (24-111 nmol/L). In a clinical laboratory Abbott 25OHD immunoassays are a useful, rapid and accurate method for measuring total 25OHD. The new generation of the assay was confirmed to be reliable, accurate, and a good indicator for 25OHD measurement. More study is needed to establish reference intervals that correctly represent the healthy population in Ireland.

  16. Sonoclot evaluation of whole blood coagulation in healthy adult dogs.

    PubMed

    Babski, Danielle M; Brainard, Benjamin M; Krimer, Paula M; Ralph, Alan G; Pittman, Jennifer R; Koenig, Amie

    2012-12-01

    To establish a standard protocol for analysis of canine whole blood and generate reference intervals for healthy dogs using the Sonoclot analyzer, and to compare Sonoclot values to standard and viscoelastic coagulation tests. Prospective study. Veterinary University research facility and teaching hospital. Twelve healthy random source dogs and 52 healthy dogs from the general veterinary school population. Blood sampling for viscoelastic coagulation testing. Blood was collected from 12 healthy adult dogs by jugular venipuncture. After a rest period at room temperature of 30, 60, or 120 minutes, 340 μL of citrated blood was added to 20 μL of 0.2 M CaCl(2) in 1 of 2 cuvette types warmed to 37° C. Cuvettes contained a magnetic stir-bar with glass beads (gbACT+) or only a magnetic stir-bar (nonACT). Reference interval samples were collected from 52 healthy adult dogs and analyzed in duplicate. The ACT, CR, and PF were not affected by duration of rest period for either cuvette type. ACT variability was decreased when using gbACT+ cuvettes (P < 0.05). In normal dogs reference intervals (mean ± 2 SD) using gbACT+ cuvettes were: ACT 56.0-154.0 seconds, CR 14.85-46.0, and PF 2.1-4.05. ACT correlated to TEG R-time, K-time, and angle, while CR correlated with all TEG parameters. Fibrinogen correlated with ACT, CR, and PF. Sonoclot did not correlate with other common coagulation tests. Sonoclot provides viscoelastic evaluation of canine whole blood coagulation and correlated to several TEG parameters and fibrinogen. A standard protocol and reference intervals were established. © Veterinary Emergency and Critical Care Society 2012.

  17. Development of Salivary Cortisol Circadian Rhythm and Reference Intervals in Full-Term Infants

    PubMed Central

    Ivars, Katrin; Nelson, Nina; Theodorsson, Annette; Theodorsson, Elvar; Ström, Jakob O.; Mörelius, Evalotte

    2015-01-01

    Background Cortisol concentrations in plasma display a circadian rhythm in adults and children older than one year. Earlier studies report divergent results regarding when cortisol circadian rhythm is established. The present study aims to investigate at what age infants develop a circadian rhythm, as well as the possible influences of behavioral regularity and daily life trauma on when the rhythm is established. Furthermore, we determine age-related reference intervals for cortisol concentrations in saliva during the first year of life. Methods 130 healthy full-term infants were included in a prospective, longitudinal study with saliva sampling on two consecutive days, in the morning (07:30-09:30), noon (10:00-12:00) and evening (19:30-21:30), each month from birth until the infant was twelve months old. Information about development of behavioral regularity and potential exposure to trauma was obtained from the parents through the Baby Behavior Questionnaire and the Life Incidence of Traumatic Events checklist. Results A significant group-level circadian rhythm of salivary cortisol secretion was established at one month, and remained throughout the first year of life, although there was considerable individual variability. No correlation was found between development of cortisol circadian rhythm and the results from either the Baby Behavior Questionnaire or the Life Incidence of Traumatic Events checklist. The study presents salivary cortisol reference intervals for infants during the first twelve months of life. Conclusions Cortisol circadian rhythm in infants is already established by one month of age, earlier than previous studies have shown. The current study also provides first year age-related reference intervals for salivary cortisol levels in healthy, full-term infants. PMID:26086734

  18. An intermediate orbit calculated from three position vectors: accuracy of approximation of a perturbed motion. (Russian Title: Промежуточная орбита, вычисленная по трем векторам положения: точность аппроксимации возмущенного движения)

    NASA Astrophysics Data System (ADS)

    Shefer, V. A.

    2015-12-01

    We examine intermediate perturbed orbit proposed by the author previously, defined from the three position vectors of a small celestial body. It is shown theoretically, that at a small reference time interval covering the body positions the approximation accuracy of real motion by this orbit corresponds approximately to the fourth order of tangency. The smaller reference interval of time, the better this correspondence. Laws of variation of the methodical errors in constructing intermediate orbit subject to the length of reference time interval are deduced. According to these laws, the convergence rate of the method to the exact solution (upon reducing the reference interval of time) in the general case is higher by three orders of magnitude than in the case of conventional methods using Keplerian unperturbed orbit. The considered orbit is among the most accurate in set of orbits of their class determined by the order of tangency. The theoretical results are validated by numerical examples. The work was supported by the Ministry of Education and Science of the Russian Federation, project no. 2014/223(1567).

  19. Spatial interpolation of daily evapotranspiration data in the Texas High Plains

    USDA-ARS?s Scientific Manuscript database

    The Texas High Plains Evapotranspiration (ET) Network collects meteorological data from grass-referenced weather stations at hourly intervals and estimates hourly and daily reference ET using the American Society of Civil Engineers (ASCE) Standardized Reference ET equation. Producers in the Texas Hi...

  20. Reference intervals for putative biomarkers of drug-induced liver injury and liver regeneration in healthy human volunteers.

    PubMed

    Francis, Ben; Clarke, Joanna I; Walker, Lauren E; Brillant, Nathalie; Jorgensen, Andrea L; Park, B Kevin; Pirmohamed, Munir; Antoine, Daniel J

    2018-05-02

    The potential of mechanistic biomarkers to improve the prediction of drug-induced liver injury (DILI) and hepatic regeneration is widely acknowledged. We sought to determine reference intervals for new biomarkers of DILI and regeneration as well as to characterize their natural variability and impact of diurnal variation. Serum samples from 200 healthy volunteers were recruited as part of a cross sectional study; of these, 50 subjects had weekly serial sampling over 3 weeks, while 24 had intensive blood sampling over a 24h period. Alanine aminotransferase (ALT), MicroRNA-122 (miR-122), high mobility group box-1 (HMGB1), total keratin-18 (FL-K18), caspase cleaved keratin-18 (cc-K18), glutamate dehydrogenase (GLDH) and colony stimulating factor-1 (CSF-1) were assessed by validated assays. Reference intervals were established for each biomarker based on the 97.5% quantile (90% CI) following the assessment of fixed effects in univariate and multivariable models (ALT 50 (41-50) U/l, miR-122 3548 (2912-4321) copies/µl, HMGB1 2.3 (2.2-2.4) ng/ml, FL-K18 475 (456-488) U/l, cc-K18 272 (256-291) U/l, GLDH 27 (26-30) U/l and CSF-1 2.4 (2.3-2.9) ng/ml). There was a small but significant intra-individual time random effect detected but no significant impact of diurnal variation was observed, with the exception of GLDH. Reference intervals for novel DILI biomarkers have been described for the first time. An upper limit of a reference range might represent the most appropriate method to utilize these data. Regulatory authorities have published letters of support encouraging further qualification of leading candidate biomarkers. These data can now be used to interpret data from exploratory clinical DILI studies and to assist their further qualification. Drug-induced liver injury (DILI) has a big impact on patient health and the development of new medicines. Unfortunately, currently used blood-based tests to assess liver injury and recovery suffer from insufficiencies. Newer blood-based tests (biomarkers) have been described that accurately predict the onset and recovery from DILI. Here, in this study we describe reference intervals from investigations designed, for the first time, with the intension to assess the natural variation of these newer biomarkers in healthy volunteers. The outcomes of these results can be used to aid the interpretation of data from patients with suspected liver toxicity. Copyright © 2018. Published by Elsevier B.V.

  1. The Use of One-Sample Prediction Intervals for Estimating CO2 Scrubber Canister Durations

    DTIC Science & Technology

    2012-10-01

    Grade and 812 D-Grade Sofnolime.3 Definitions According to Devore,4 A CI (confidence interval) refers to a parameter, or population ... characteristic , whose value is fixed but unknown to us. In contrast, a future value of Y is not a parameter but instead a random variable; for this

  2. 40 CFR 1066.605 - Mass-based and molar-based exhaust emission calculations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the test interval, corrected to standard temperature and pressure. m PMfil = mass of particulate... = stabilized, ht = hot transient), corrected to standard reference conditions. m PMfil = mass of particulate... stabilized), corrected to standard reference conditions. m PMfil = mass of particulate matter emissions on...

  3. 4D Dynamic Required Navigation Performance Final Report

    NASA Technical Reports Server (NTRS)

    Finkelsztein, Daniel M.; Sturdy, James L.; Alaverdi, Omeed; Hochwarth, Joachim K.

    2011-01-01

    New advanced four dimensional trajectory (4DT) procedures under consideration for the Next Generation Air Transportation System (NextGen) require an aircraft to precisely navigate relative to a moving reference such as another aircraft. Examples are Self-Separation for enroute operations and Interval Management for in-trail and merging operations. The current construct of Required Navigation Performance (RNP), defined for fixed-reference-frame navigation, is not sufficiently specified to be applicable to defining performance levels of such air-to-air procedures. An extension of RNP to air-to-air navigation would enable these advanced procedures to be implemented with a specified level of performance. The objective of this research effort was to propose new 4D Dynamic RNP constructs that account for the dynamic spatial and temporal nature of Interval Management and Self-Separation, develop mathematical models of the Dynamic RNP constructs, "Required Self-Separation Performance" and "Required Interval Management Performance," and to analyze the performance characteristics of these air-to-air procedures using the newly developed models. This final report summarizes the activities led by Raytheon, in collaboration with GE Aviation and SAIC, and presents the results from this research effort to expand the RNP concept to a dynamic 4D frame of reference.

  4. Analytical validation and establishment of reference intervals for a 'high-sensitivity' cardiac troponin-T assay in horses.

    PubMed

    Shields, E; Seiden-Long, I; Massie, S; Passante, S; Leguillette, R

    2016-06-13

    Cardiac troponin-I assays have been validated in horses.'High-sensitivity' cardiac troponin assays are now the standard in human cardiology. Appropriately validate the'high-sensitivity' cardiac Troponin-T (hscTnT) assay for clinical use in horses, establish reference intervals, determine the biological variation, and demonstrate assay utility in selected clinical cases. Analytical validation of the Roche hscTnT assay included within- and between-run precision, linear dose response, limit of quantitation (LoQ), stability, and comparison with cTn-I (iSTAT). Reference intervals and biological variation were determined using adult, healthy, Non-Competition Horses (N = 125) and Racing-Thoroughbreds (N = 178). HscTnT levels were measured in two horses with cardiac pathology. The hscTnT demonstrates acceptable within-run (L1 = 6.5 ng/L, CV 14.9 %, L2 = 10.1 ng/L, CV 8.7 %, L3 = 15.3 ng/L, CV 5.4 %) and between-run precision (L1 = 12.2 ng/L, CV 8.4 %, L2 = 57.0 ng/L, CV 8.4 %, L3 = 256.0 ng/L, CV 9.0 %). The assay was linear from 3 to 391 ng/L. The LoQ was validated at 3 ng/L. Samples demonstrated insignificant decay over freeze-thaw cycle. Comparison with cTnI assay showed excellent correlation (range: 8.0-3535.0 ng/L, R(2) = 0.9996). Reference intervals: The upper 95(th) and 99(th) percentile of the hscTnT population distribution were 6.8 and 16.2 ng/L in Non-Competition Horses, and 14.0 and 23.2 ng/L in Racing-Thoroughbreds. Between-breed, diurnal effect, and between-day variation was below LoQ. Two clinical cases with presumed cardiac pathology had hscTnT levels of 220.9 ng/L and 5723.0 ng/L. This benchmark study is the first to comply with CLSI guidelines, thus further establishing the performance characteristics of the hscTnT assay, and reference intervals in healthy horses. Two clinical cases demonstrated further the clinical utility of the assay.

  5. The Application of a Statistical Analysis Software Package to Explosive Testing

    DTIC Science & Technology

    1993-12-01

    deviation not corrected for test interval. M refer to equation 2. s refer to equation 3. G refer to section 2.1, C 36 Appendix I : Program Structured ...APPENDIX I: Program Structured Diagrams 37 APPENDIX II: Bruceton Reference Graphs 39 APPENDIX III: Input and Output Data File Format 44 APPENDIX IV...directly from Graph II, which has been digitised and incorporated into the program . IfM falls below 0.3, the curve that is closest to diff( eq . 3a) is

  6. [Full blood count reference values in children of 8 to 12 years old residing at 2,760 m above sea level].

    PubMed

    Armando García-Miranda, L; Contreras, I; Estrada, J A

    2014-04-01

    To determine reference values for full blood count parameters in a population of children 8 to 12 years old, living at an altitude of 2760 m above sea level. Our sample consisted of 102 individuals on whom a full blood count was performed. The parameters included: total number of red blood cells, platelets, white cells, and a differential count (millions/μl and %) of neutrophils, lymphocytes, monocytes, eosinophils and basophils. Additionally, we obtained values for hemoglobin, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin, concentration of corpuscular hemoglobin and red blood cell distribution width. The results were statistically analyzed with a non-parametric test, to divide the sample in quartiles and obtain the lower and upper limits for our intervals. Moreover, the values for the intervals obtained from this analysis were compared to intervals obtained estimating+- 2 standard deviations above and below from our mean values. Our results showed significant differences compared to normal interval values reported for the adult Mexican population in most of the parameters studied. The full blood count is an important laboratory test used routinely for the initial assessment of a patient. Values of full blood counts in healthy individuals vary according to gender, age and geographic location; therefore, each population should have its own reference values. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  7. Ethnic variations in morbidity and mortality from lower respiratory tract infections: a retrospective cohort study.

    PubMed

    Simpson, Colin R; Steiner, Markus Fc; Cezard, Genevieve; Bansal, Narinder; Fischbacher, Colin; Douglas, Anne; Bhopal, Raj; Sheikh, Aziz

    2015-10-01

    There is evidence of substantial ethnic variations in asthma morbidity and the risk of hospitalisation, but the picture in relation to lower respiratory tract infections is unclear. We carried out an observational study to identify ethnic group differences for lower respiratory tract infections. A retrospective, cohort study. Scotland. 4.65 million people on whom information was available from the 2001 census, followed from May 2001 to April 2010. Hospitalisations and deaths (any time following first hospitalisation) from lower respiratory tract infections, adjusted risk ratios and hazard ratios by ethnicity and sex were calculated. We multiplied ratios and confidence intervals by 100, so the reference Scottish White population's risk ratio and hazard ratio was 100. Among men, adjusted risk ratios for lower respiratory tract infection hospitalisation were lower in Other White British (80, 95% confidence interval 73-86) and Chinese (69, 95% confidence interval 56-84) populations and higher in Pakistani groups (152, 95% confidence interval 136-169). In women, results were mostly similar to those in men (e.g. Chinese 68, 95% confidence interval 56-82), although higher adjusted risk ratios were found among women of the Other South Asians group (145, 95% confidence interval 120-175). Survival (adjusted hazard ratio) following lower respiratory tract infection for Pakistani men (54, 95% confidence interval 39-74) and women (31, 95% confidence interval 18-53) was better than the reference population. Substantial differences in the rates of lower respiratory tract infections amongst different ethnic groups in Scotland were found. Pakistani men and women had particularly high rates of lower respiratory tract infection hospitalisation. The reasons behind the high rates of lower respiratory tract infection in the Pakistani community are now required. © The Royal Society of Medicine.

  8. Magnetic Resonance Fingerprinting with short relaxation intervals.

    PubMed

    Amthor, Thomas; Doneva, Mariya; Koken, Peter; Sommer, Karsten; Meineke, Jakob; Börnert, Peter

    2017-09-01

    The aim of this study was to investigate a technique for improving the performance of Magnetic Resonance Fingerprinting (MRF) in repetitive sampling schemes, in particular for 3D MRF acquisition, by shortening relaxation intervals between MRF pulse train repetitions. A calculation method for MRF dictionaries adapted to short relaxation intervals and non-relaxed initial spin states is presented, based on the concept of stationary fingerprints. The method is applicable to many different k-space sampling schemes in 2D and 3D. For accuracy analysis, T 1 and T 2 values of a phantom are determined by single-slice Cartesian MRF for different relaxation intervals and are compared with quantitative reference measurements. The relevance of slice profile effects is also investigated in this case. To further illustrate the capabilities of the method, an application to in-vivo spiral 3D MRF measurements is demonstrated. The proposed computation method enables accurate parameter estimation even for the shortest relaxation intervals, as investigated for different sampling patterns in 2D and 3D. In 2D Cartesian measurements, we achieved a scan acceleration of more than a factor of two, while maintaining acceptable accuracy: The largest T 1 values of a sample set deviated from their reference values by 0.3% (longest relaxation interval) and 2.4% (shortest relaxation interval). The largest T 2 values showed systematic deviations of up to 10% for all relaxation intervals, which is discussed. The influence of slice profile effects for multislice acquisition is shown to become increasingly relevant for short relaxation intervals. In 3D spiral measurements, a scan time reduction of 36% was achieved, maintaining the quality of in-vivo T1 and T2 maps. Reducing the relaxation interval between MRF sequence repetitions using stationary fingerprint dictionaries is a feasible method to improve the scan efficiency of MRF sequences. The method enables fast implementations of 3D spatially resolved MRF. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Cape Canaveral, Florida range reference atmosphere 0-70 km altitude

    NASA Technical Reports Server (NTRS)

    Tingle, A. (Editor)

    1983-01-01

    The RRA contains tabulations for monthly and annual means, standard deviations, skewness coefficients for wind speed, pressure temperature, density, water vapor pressure, virtual temperature, dew-point temperature, and the means and standard deviations for the zonal and meridional wind components and the linear (product moment) correlation coefficient between the wind components. These statistical parameters are tabulated at the station elevation and at 1 km intervals from sea level to 30 km and at 2 km intervals from 30 to 90 km altitude. The wind statistics are given at approximately 10 m above the station elevations and at altitudes with respect to mean sea level thereafter. For those range sites without rocketsonde measurements, the RRAs terminate at 30 km altitude or they are extended, if required, when rocketsonde data from a nearby launch site are available. There are four sets of tables for each of the 12 monthly reference periods and the annual reference period.

  10. Quality assurance and quality control in light stable isotope laboratories: A case study of Rio Grande, Texas, water samples

    USGS Publications Warehouse

    Coplen, T.B.; Qi, H.

    2009-01-01

    New isotope laboratories can achieve the goal of reporting the same isotopic composition within analytical uncertainty for the same material analysed decades apart by (1) writing their own acceptance testing procedures and putting them into their mass spectrometric or laser-based isotope-ratio equipment procurement contract, (2) requiring a manufacturer to demonstrate acceptable performance using all sample ports provided with the instrumentation, (3) for each medium to be analysed, prepare two local reference materials substantially different in isotopic composition to encompass the range in isotopic composition expected in the laboratory and calibrated them with isotopic reference materials available from the International Atomic Energy Agency (IAEA) or the US National Institute of Standards and Technology (NIST), (4) using the optimum storage containers (for water samples, sealing in glass ampoules that are sterilised after sealing is satisfactory), (5) interspersing among sample unknowns local laboratory isotopic reference materials daily (internationally distributed isotopic reference materials can be ordered at three-year intervals, and can be used for elemental analyser analyses and other analyses that consume less than 1 mg of material) - this process applies to H, C, N, O, and S isotope ratios, (6) calculating isotopic compositions of unknowns by normalising isotopic data to that of local reference materials, which have been calibrated to internationally distributed isotopic reference materials, (7) reporting results on scales normalised to internationally distributed isotopic reference materials (where they are available) and providing to sample submitters the isotopic compositions of internationally distributed isotopic reference materials of the same substance had they been analysed with unknowns, (8) providing an audit trail in the laboratory for analytical results - this trail commonly will be in electronic format and might include a laboratory information management system, (9) making at regular intervals a complete backup of laboratory analytical data (both of samples logged into the laboratory and of mass spectrometric analyses), being sure to store one copy of this backup offsite, and (10) participating in interlaboratory comparison exercises sponsored by the IAEA and other agencies at regular intervals. ?? Taylor & Francis.

  11. HEMATOLOGY AND PLASMA CHEMISTRY OF THE PLOUGHSHARE TORTOISE (ASTROCHELYS YNIPHORA) IN A CAPTIVE BREEDING PROGRAM.

    PubMed

    López, Javier; Waters, Michael; Routh, Andrew; Rakotonanahary, Tsanta F; Woolaver, Lance; Thomasson, Ann; Holmes, Emma; Steinmetz, Hanspeter W

    2017-03-01

    Blood samples from 172 captive and 40 wild, healthy, juvenile and adult, ploughshare tortoises ( Astrochelys yniphora ) were analyzed to determine hematological and biochemical reference intervals. Hematological analytes included packed cell volume (PCV), white blood cell count (WBC), and WBC differential estimates. Biochemical analysis included total protein measured by photometry (TP) and by refractometry (TPr), albumin (ALB), creatine kinase (CK), aspartate aminotransferase (AST), glutamate dehydrogenase (GLDH), bile acids (BA), calcium (Ca), phosphorus (P), urea (UREA), and uric acid (UA). The jugular vein was identified as the preferred venipuncture site as subcarapacial vein venipuncture resulted in regular hemodilution. In due consideration of small sample sizes in some of the groups studied, adult tortoises had significantly higher plasma GLDH activity and TPr, TP, ALB, BA, and UREA concentrations and significantly lower AST activity and P concentration than juveniles. Captivity had a significant influence in some reference intervals, with captive adults presenting significantly higher WBC, and estimated counts of all white cell types as well as UREA and TPr than wild counterparts. Captive juveniles also showed significantly higher estimated monocyte and lower estimated eosinophil and basophil counts. Although these differences most likely reflect local environmental or dietary differences, without representing pathology or a deviation from the normal, they question the applicability of reference values from captive animals to wild animals and vice versa. Significant sex differences were only observed for PCV and UA. The reported reference intervals may serve as benchmarks for clinical assessment and conservation of this critically endangered species.

  12. Reference intervals and diagnostic ranges for serum free κ and free λ immunoglobulin light chains vary by instrument platform: Implications for classification of patient results in a multi-center study.

    PubMed

    Cotten, Steven W; Shajani-Yi, Zahra; Cervinski, Mark A; Voorhees, Timothy; Tuchman, Sascha A; Korpi-Steiner, Nichole

    2018-06-06

    Serum free light chain (FLC) immunoglobulins are key biomarkers that aid in the diagnosis, prognosis and assessment of treatment response in patients with plasma cell disorders (PCD). Here we investigated the transference of manufacturer's reported κFLC, λFLC and κ to λ FLC reference intervals (RI) and established de novo FLC RI and diagnostic ranges on four instruments at three academic medical centers. In addition, we also compared the classification of patient FLC results using manufacturer's versus established RIs and diagnostic ranges. CLSI EP28-A3C protocol was applied to investigate transference and establishment of FLC reference intervals on the cobas (Roche), Immage (Beckman), Optilite and SPA Plus (Binding Site). Serum κ FLC and λ FLC were measured in reference sera (N = 126) with estimation of central 95% RIs and FLC ratio diagnostic range (total range). Frequencies (%) in patient FLC results (N > 380 per institution) classified above, below or within manufacturer's versus established FLC RI were compared. Three of four instrument platforms did not exhibit acceptable transference of manufacturer's reported κFLC RI. The manufacturer's reported FLC total diagnostic range did not encompass all values observed in reference sera for any of the four platforms evaluated. Established FLC ratio diagnostic ranges reduced the frequency of patient results classified above range for three of four platforms evaluated. Transference of manufacturer's reported FLC RIs may be inappropriate for select instrument platforms. De novo establishment of FLC RIs specific to instrument platform is highly recommended in order to assure correct patient result classification. Copyright © 2017. Published by Elsevier Inc.

  13. Extracting respiratory information from seismocardiogram signals acquired on the chest using a miniature accelerometer.

    PubMed

    Pandia, Keya; Inan, Omer T; Kovacs, Gregory T A; Giovangrandi, Laurent

    2012-10-01

    Seismocardiography (SCG) is a non-invasive measurement of the vibrations of the chest caused by the heartbeat. SCG signals can be measured using a miniature accelerometer attached to the chest, and are thus well-suited for unobtrusive and long-term patient monitoring. Additionally, SCG contains information relating to both cardiovascular and respiratory systems. In this work, algorithms were developed for extracting three respiration-dependent features of the SCG signal: intensity modulation, timing interval changes within each heartbeat, and timing interval changes between successive heartbeats. Simultaneously with a reference respiration belt, SCG signals were measured from 20 healthy subjects and a respiration rate was estimated using each of the three SCG features and the reference signal. The agreement between each of the three accelerometer-derived respiration rate measurements was computed with respect to the respiration rate derived from the reference respiration belt. The respiration rate obtained from the intensity modulation in the SCG signal was found to be in closest agreement with the respiration rate obtained from the reference respiration belt: the bias was found to be 0.06 breaths per minute with a 95% confidence interval of -0.99 to 1.11 breaths per minute. The limits of agreement between the respiration rates estimated using SCG (intensity modulation) and the reference were within the clinically relevant ranges given in existing literature, demonstrating that SCG could be used for both cardiovascular and respiratory monitoring. Furthermore, phases of each of the three SCG parameters were investigated at four instances of a respiration cycle-start inspiration, peak inspiration, start expiration, and peak expiration-and during breath hold (apnea). The phases of the three SCG parameters observed during the respiration cycle were congruent with existing literature and physiologically expected trends.

  14. Quantity quotient reporting. A proposal for a standardized presentation of laboratory results.

    PubMed

    Haeckel, Rainer; Wosniok, Werner

    2009-01-01

    Laboratory results are reported in different units (despite international recommendations for SI units) together with different reference limits, of which several exist for many quantities. It is proposed to adopt the concept of the intelligence quotient and to report quantitative results as a quantity quotient (QQ) in laboratory medicine. This quotient is essentially the difference (measured result minus mean or mode value of the reference interval) divided by the observed biological variation CV(o). Thus, all quantities are reported in the same unit system with the same reference limits (for convenience shifted to e.g., 80-120). The critical difference can also be included in this standardization concept. In this way the information of reference intervals and the original result are integrated into one combined value, which has the same format for all quantities suited for quotient reporting (QR). The proposal of QR does not interfere with neither the current concepts of traceability, SI units or method standardization. This proposal represents a further step towards harmonization of reporting. It provides simple values which can be interpreted easily by physicians and their patients.

  15. The role of general practice in routes to diagnosis of lung cancer in Denmark: a population-based study of general practice involvement, diagnostic activity and diagnostic intervals.

    PubMed

    Guldbrandt, Louise Mahncke; Fenger-Grøn, Morten; Rasmussen, Torben Riis; Jensen, Henry; Vedsted, Peter

    2015-01-22

    Lung cancer stage at diagnosis predicts possible curative treatment. In Denmark and the UK, lung cancer patients have lower survival rates than citizens in most other European countries, which may partly be explained by a comparatively longer diagnostic interval in these two countries. In Denmark, a pathway was introduced in 2008 allowing general practitioners (GPs) to refer patients suspected of having lung cancer directly to fast-track diagnostics. However, symptom presentation of lung cancer in general practice is known to be diverse and complex, and systematic knowledge of the routes to diagnosis is needed to enable earlier lung cancer diagnosis in Denmark. This study aims to describe the routes to diagnosis, the diagnostic activity preceding diagnosis and the diagnostic intervals for lung cancer in the Danish setting. We conducted a national registry-based cohort study on 971 consecutive incident lung cancer patients in 2010 using data from national registries and GP questionnaires. GPs were involved in 68.3% of cancer patients' diagnostic pathways, and 27.4% of lung cancer patients were referred from the GP to fast-track diagnostic work-up. A minimum of one X-ray was performed in 85.6% of all cases before diagnosis. Patients referred through a fast-track route more often had diagnostic X-rays (66.0%) than patients who did not go through fast-track (49.4%). Overall, 33.6% of all patients had two or more X-rays performed during the 90 days before diagnosis. Patients whose symptoms were interpreted as non-alarm symptoms or who were not referred to fast-track were more likely to experience a long diagnostic interval than patients whose symptoms were interpreted as alarm symptoms or who were referred to fast-track. Lung cancer patients followed several diagnostic pathways. The existing fast-track pathway must be supplemented to ensure earlier detection of lung cancer. The high incidence of multiple X-rays warrants a continued effort to develop more accurate lung cancer tests for use in primary care.

  16. Establishment of reference intervals for osteoarthritis-related soluble biomarkers: the FNIH/OARSI OA Biomarkers Consortium.

    PubMed

    Kraus, Virginia B; Hargrove, David E; Hunter, David J; Renner, Jordan B; Jordan, Joanne M

    2017-01-01

    To establish reference intervals for osteoarthritis (OA)-related biomarkers used in the Foundation for the National Institutes of Health (FNIH) OA Biomarkers Consortium Project. A total of 129 'multijoint controls' were selected from 2722 African-American and Caucasian men and women in the Johnston County Osteoarthritis Project. The majority (79%) of those eligible (with biospecimens and baseline data) also had one or more follow-up evaluations 5-15 years later. Multijoint controls were selected to be free of radiographic hand, hip, knee and lumbar spine osteoarthritis (OA), to have no knee or hip symptoms, and minimal hand and spine symptoms at all available time points. Eighteen biomarkers were evaluated in serum (s) and/or urine (u) by ELISA. Reference intervals and partitioning by gender and race were performed with EP Evaluator software. Controls were 64% women, 33% African-Americans, mean age 59 years and mean body mass index 29 kg/m 2 . Three biomarkers were associated with age: sHyaluronan (positively), sN-terminal propeptide of collagen IIA (positively) and sCol2-3/4 C-terminal cleavage product of types I and II collagen (negatively). Exploratory analyses suggested that separate reference intervals may be warranted on the basis of gender for uC-terminal cross-linked telopeptide of type II collagen (uCTXII), sMatrix metalloproteinase-3, uNitrated type II collagen degradation fragment (uCol2-1 NO2) and sHyaluronan, and on the basis of race for uCTXII, sCartilage oligomeric matrix protein, sC-terminal cross-linked telopeptide of type I collagen and uCol2-1 NO2. To our knowledge, this represents the best and most stringent control group ever assayed for OA-related biomarkers. These well-phenotyped controls, representing a similar age demographic to that of the OA Initiative-FNIH main study sample, provide a context for interpretation of OA subject biomarker data. The freely available data set also provides a reference for future human studies. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  17. Auditory Training for Adults Who Have Hearing Loss: A Comparison of Spaced versus Massed Practice Schedules

    ERIC Educational Resources Information Center

    Tye-Murray, Nancy; Spehar, Brent; Barcroft, Joe; Sommers, Mitchell

    2017-01-01

    Purpose: The spacing effect in human memory research refers to situations in which people learn items better when they study items in spaced intervals rather than massed intervals. This investigation was conducted to compare the efficacy of meaning-oriented auditory training when administered with a spaced versus massed practice schedule. Method:…

  18. Statistical considerations for harmonization of the global multicenter study on reference values.

    PubMed

    Ichihara, Kiyoshi

    2014-05-15

    The global multicenter study on reference values coordinated by the Committee on Reference Intervals and Decision Limits (C-RIDL) of the IFCC was launched in December 2011, targeting 45 commonly tested analytes with the following objectives: 1) to derive reference intervals (RIs) country by country using a common protocol, and 2) to explore regionality/ethnicity of reference values by aligning test results among the countries. To achieve these objectives, it is crucial to harmonize 1) the protocol for recruitment and sampling, 2) statistical procedures for deriving the RI, and 3) test results through measurement of a panel of sera in common. For harmonized recruitment, very lenient inclusion/exclusion criteria were adopted in view of differences in interpretation of what constitutes healthiness by different cultures and investigators. This policy may require secondary exclusion of individuals according to the standard of each country at the time of deriving RIs. An iterative optimization procedure, called the latent abnormal values exclusion (LAVE) method, can be applied to automate the process of refining the choice of reference individuals. For global comparison of reference values, test results must be harmonized, based on the among-country, pair-wise linear relationships of test values for the panel. Traceability of reference values can be ensured based on values assigned indirectly to the panel through collaborative measurement of certified reference materials. The validity of the adopted strategies is discussed in this article, based on interim results obtained to date from five countries. Special considerations are made for dissociation of RIs by parametric and nonparametric methods and between-country difference in the effect of body mass index on reference values. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Interval stability for complex systems

    NASA Astrophysics Data System (ADS)

    Klinshov, Vladimir V.; Kirillov, Sergey; Kurths, Jürgen; Nekorkin, Vladimir I.

    2018-04-01

    Stability of dynamical systems against strong perturbations is an important problem of nonlinear dynamics relevant to many applications in various areas. Here, we develop a novel concept of interval stability, referring to the behavior of the perturbed system during a finite time interval. Based on this concept, we suggest new measures of stability, namely interval basin stability (IBS) and interval stability threshold (IST). IBS characterizes the likelihood that the perturbed system returns to the stable regime (attractor) in a given time. IST provides the minimal magnitude of the perturbation capable to disrupt the stable regime for a given interval of time. The suggested measures provide important information about the system susceptibility to external perturbations which may be useful for practical applications. Moreover, from a theoretical viewpoint the interval stability measures are shown to bridge the gap between linear and asymptotic stability. We also suggest numerical algorithms for quantification of the interval stability characteristics and demonstrate their potential for several dynamical systems of various nature, such as power grids and neural networks.

  20. Specifying real-time systems with interval logic

    NASA Technical Reports Server (NTRS)

    Rushby, John

    1988-01-01

    Pure temporal logic makes no reference to time. An interval temporal logic and an extension to that logic which includes real time constraints are described. The application of this logic by giving a specification for the well-known lift (elevator) example is demonstrated. It is shown how interval logic can be extended to include a notion of process. How the specification language and verification environment of EHDM could be enhanced to support this logic is described. A specification of the alternating bit protocol in this extended version of the specification language of EHDM is given.

  1. Serum biochemical reference intervals for free-living Sand Tiger sharks (Carcharias taurus) from east Australian waters.

    PubMed

    Otway, Nicholas M

    2015-06-01

    Sharks are top-order predators in ocean food chains and the star attractions in aquaria worldwide. Unfortunately, blood biochemistry reference intervals (RI) have been determined for few species. The study aims to establish serum biochemical RI for free-living Sand Tiger sharks (Carcharias taurus) off eastern Australia. Thirty-seven sharks were captured and their sex, length, weight, reproductive maturity, and health status were recorded. After blood collection, serum analytes were quantified using standard analytical and statistical methods. Reference intervals, means, medians, and 90% confidence intervals were generated. Physiologic data from live and necropsied sharks were used to enhance the study results. Thirty healthy sharks were included in the study. Albumin could not be detected. With the exception of ALP activity, values were unaffected by sex, length, weight, age, and life-history stage. The means (RI) were: sodium 258 (249-267) mmol/L, potassium 5.0 (4.3-5.7) mmol/L, chloride 242 (227-257) mmol/L, inorganic phosphate 1.8 (1.7-2.0) mmol/L, total calcium 3.9 (3.3-4.4) mmol/L, magnesium 1.9 (1.6-2.2) mmol/L, glucose 2.7 (2.2-3.2) mmol/L, urea 377 (360-394) mmol/L, ALP 20 (8-31) U/L, ALT 3 U/L (no RI), AST 29 (13-45) U/L, CK 42 (5-79) U/L, total protein 30 (24-36) g/L, triglyceride 0.3 (0.1-0.6) mmol/L, cholesterol 1.4 (0.9-2.1) mmol/L, creatinine 32 μmol/L (no RI), total bilirubin 1.5 μmol/L (no RI), and osmolarity 1082 (1027-1136) mmol/L. These preliminary RI will assist with the clinical evaluation and treatment of captive and free-living Sand Tiger sharks worldwide. Studies with more animals will increase the precision of upper and lower reference limits. © 2015 American Society for Veterinary Clinical Pathology.

  2. Serum chemistry of free-ranging white whales (Delphinapterus leucas) in Svalbard.

    PubMed

    Tryland, Morten; Thoresen, Stein Istre; Kovacs, Kit M; Lydersen, Christian

    2006-06-01

    Abnormal physiological conditions and diseases can change the concentrations of enzymes, metabolites, and minerals in the body. Serum chemistry information may thus be indicative of a specific disease; interpretation of such information requires knowledge of serum chemistry reference intervals from a seemingly healthy population of the species. The aim of this study was to obtain serum chemistry reference intervals for a population of white whales. Blood samples were collected from 21 free-ranging white whales (beluga; Delphinapterus leucas). The whales were live-captured in nets during 1996-2001 in Storfjorden, Van Mijenfjorden, and Van Keulenfjorden (Svalbard, Norway). While the whales were briefly physically restrained, blood was collected from the caudal vein into vacuum tubes without anticoagulant. The blood was left to clot for 4-6 hours before serum was obtained by centrifugation. The serum samples were then kept at -20 degrees C until analysis. Enzymes (aspartate aminotransferase, alanine aminotransferase, alkaline phosphatase [ALP], creatine kinase, lactate dehydrogenase [LDH], amylase, lipase), metabolites (urea, creatinine, bilirubin, cholesterol, triglycerides, nonesterified fatty acids, glucose), and minerals (calcium, phosphate, magnesium, sodium, potassium, chloride) were analyzed in an Advia 1650 System (Bayer, Tarrytown, NY, USA). Cortisol was analyzed in an Immulite One system (Diagnostic Products Corporation, Los Angeles, CA, USA). The major blood proteins (albumin and globulins) were separated by gel electrophoresis in a Beckman Paragon electrophoresis system (Beckman Coulter, Inc., Fullerton, CA, USA). Serum values for all analytes were reported as median and range, and reference intervals were calculated as 10-90th percentiles. Activities of ALP and LDH and cortisol concentration were higher, and protein and bilirubin concentrations were lower compared with those previously reported for white whales from Canada; remaining results were strikingly similar in these 2 white whale populations. These data provide valuable serum chemistry reference intervals for future health assessments of white whales in Svalbard and other white whale populations, as well as captive individuals.

  3. Study on the influence factors of camouflage target polarization detection

    NASA Astrophysics Data System (ADS)

    Huang, Yanhua; Chen, Lei; Li, Xia; Wu, Wenyuan

    2016-10-01

    The degree of linear polarization (DOLP) expressions at any polarizer direction (PD) was deduced based on the Stokes vector and Mueller matrix. The outdoors experiments were carried out to demonstrate the expressions. This paper mainly explored the DOLP-image-Contrast (DOLPC) between the target image and the background image, and the PD and RGB waveband that be considered two important influence factors were studied for camouflage target polarization detection. It was found that the DOLPC of target and background was obviously higher than intensity image. When setting the reference direction that polarizer was perpendicular to the incident face, the DOLP image of interval angle 60 degree between PD and reference direction had relatively high DOLPC, the interval angle 45 degree was the second, and the interval angle 35 degree was the third. The outdoors polarization detection experiment of controlling waveband showed that the DOLPC results was significantly different to use 650nm, 550nm and 450nm waveband, and the polarization detection performance by using 650nm band was an optimization method.

  4. Age-dependent biochemical quantities: an approach for calculating reference intervals.

    PubMed

    Bjerner, J

    2007-01-01

    A parametric method is often preferred when calculating reference intervals for biochemical quantities, as non-parametric methods are less efficient and require more observations/study subjects. Parametric methods are complicated, however, because of three commonly encountered features. First, biochemical quantities seldom display a Gaussian distribution, and there must either be a transformation procedure to obtain such a distribution or a more complex distribution has to be used. Second, biochemical quantities are often dependent on a continuous covariate, exemplified by rising serum concentrations of MUC1 (episialin, CA15.3) with increasing age. Third, outliers often exert substantial influence on parametric estimations and therefore need to be excluded before calculations are made. The International Federation of Clinical Chemistry (IFCC) currently recommends that confidence intervals be calculated for the reference centiles obtained. However, common statistical packages allowing for the adjustment of a continuous covariate do not make this calculation. In the method described in the current study, Tukey's fence is used to eliminate outliers and two-stage transformations (modulus-exponential-normal) in order to render Gaussian distributions. Fractional polynomials are employed to model functions for mean and standard deviations dependent on a covariate, and the model is selected by maximum likelihood. Confidence intervals are calculated for the fitted centiles by combining parameter estimation and sampling uncertainties. Finally, the elimination of outliers was made dependent on covariates by reiteration. Though a good knowledge of statistical theory is needed when performing the analysis, the current method is rewarding because the results are of practical use in patient care.

  5. Establishment of Biological Reference Intervals and Reference Curve for Urea by Exploratory Parametric and Non-Parametric Quantile Regression Models.

    PubMed

    Sarkar, Rajarshi

    2013-07-01

    The validity of the entire renal function tests as a diagnostic tool depends substantially on the Biological Reference Interval (BRI) of urea. Establishment of BRI of urea is difficult partly because exclusion criteria for selection of reference data are quite rigid and partly due to the compartmentalization considerations regarding age and sex of the reference individuals. Moreover, construction of Biological Reference Curve (BRC) of urea is imperative to highlight the partitioning requirements. This a priori study examines the data collected by measuring serum urea of 3202 age and sex matched individuals, aged between 1 and 80 years, by a kinetic UV Urease/GLDH method on a Roche Cobas 6000 auto-analyzer. Mann-Whitney U test of the reference data confirmed the partitioning requirement by both age and sex. Further statistical analysis revealed the incompatibility of the data for a proposed parametric model. Hence the data was non-parametrically analysed. BRI was found to be identical for both sexes till the 2(nd) decade, and the BRI for males increased progressively 6(th) decade onwards. Four non-parametric models were postulated for construction of BRC: Gaussian kernel, double kernel, local mean and local constant, of which the last one generated the best-fitting curves. Clinical decision making should become easier and diagnostic implications of renal function tests should become more meaningful if this BRI is followed and the BRC is used as a desktop tool in conjunction with similar data for serum creatinine.

  6. Mammography interval and breast cancer mortality in women over the age of 75.

    PubMed

    Simon, Michael S; Wassertheil-Smoller, Sylvia; Thomson, Cynthia A; Ray, Roberta M; Hubbell, F Allan; Lessin, Lawrence; Lane, Dorothy S; Kuller, Lew H

    2014-11-01

    The purpose of this study is to evaluate the relationship between mammography interval and breast cancer mortality among older women with breast cancer. The study population included 1,914 women diagnosed with invasive breast cancer at age 75 or later during their participation in the Women's health initiative, with an average follow-up of 4.4 years (3.1 SD). Cause of death was based on medical record review. Mammography interval was defined as the time between the last self-reported mammogram 7 or more months prior to diagnosis, and the date of diagnosis. Multivariable adjusted hazard ratios (HR) and 95 % confidence intervals (CIs) for breast cancer mortality and all-cause mortality were computed from Cox proportional hazards analyses. Prior mammograms were reported by 73.0 % of women from 7 months to ≤2 year of diagnosis (referent group), 19.4 % (>2 to <5 years), and 7.5 % (≥5 years or no prior mammogram). Women with the longest versus shortest intervals had more poorly differentiated (28.5 % vs. 22.7 %), advanced stage (25.7 % vs. 22.9 %), and estrogen receptor negative tumors (20.9 % vs. 13.1 %). Compared to the referent group, women with intervals of >2 to <5 years or ≥5 years had an increased risk of breast cancer mortality (HR 1.62, 95 % CI 1.03-2.54) and (HR 2.80, 95 % CI 1.57-5.00), respectively, p trend = 0.0002. There was no significant relationship between mammography interval and other causes of death. These results suggest a continued role for screening mammography among women 75 years of age and older.

  7. The Role of Elicited Verbal Imitation in Toddlers' Word Learning

    ERIC Educational Resources Information Center

    Hodges, Rosemary; Munro, Natalie; Baker, Elise; McGregor, Karla; Docking, Kimberley; Arciuli, Joanne

    2016-01-01

    This study is about the role of elicited verbal imitation in toddler word learning. Forty-eight toddlers were taught eight nonwords linked to referents. During training, they were asked to imitate the nonwords. Naming of the referents was tested at three intervals (one minute later [uncued], five minutes, and 1-7 days later [cued]) and recognition…

  8. [Reference values for lead in blood in urban population in southern Brazil].

    PubMed

    Paoliello, M M; Gutierrez, P R; Turini, C A; Matsuo, T; Mezzaroba, L; Barbosa, D S; Carvalho, S R; Alvarenga, A L; Rezende, M I; Figueiroa, G A; Leite, V G; Gutierrez, A C; Lobo, B C; Cascales, R A

    2001-05-01

    To describe the reference values for lead in blood in an urban population in the city of Londrina, in the state of Paraná, Brazil. The reference population was composed of 520 adult volunteers who were assessed from November 1994 to December 1996. Exclusion criteria were: occupational exposure to lead, exposure through personal habits or practices, smoking more than 10 cigarettes per day, and living near industrial plants or other places that use lead in their production processes. Also excluded were individuals with abnormal clinical or laboratory results or with chronic diseases or cardiovascular disorders. Lead blood levels were determined using air-acetylene flame atomic absorption spectrophotometry. The detectable limit was 1.23 micrograms/dL. After the analyses of lead in blood, the following values were determined: minimum value, first quartile, median, third quartile, and maximum value; geometric mean; 95% confidence interval; experimental interval; and reference value. The reference values for lead in blood ranged from 1.20 micrograms/dL to 13.72 micrograms/dL. The geometric mean was 5.5 micrograms/dL. In general, the values found in this study are lower than those that have been reported for other countries. Additional data should be gathered from Brazilian populations living in more-industrialized areas.

  9. Automatic frequency control for FM transmitter

    NASA Technical Reports Server (NTRS)

    Honnell, M. A. (Inventor)

    1974-01-01

    An automatic frequency control circuit for an FM television transmitter is described. The frequency of the transmitter is sampled during what is termed the back porch portion of the horizontal synchronizing pulse which occurs during the retrace interval, the frequency sample compared with the frequency of a reference oscillator, and a correction applied to the frequency of the transmitter during this portion of the retrace interval.

  10. Global Geopotential Modelling from Satellite-to-Satellite Tracking,

    DTIC Science & Technology

    1981-10-01

    measured range-rate sampled at regular intervals. The expansion of the potential has been truncated at degree n = 331, because little information on...averaging interval is 4 s , and sampling takes place every 4 s ; if residual data are used, with respect to a reference model of specified accuracy, complete...LEGFDN, MODEL, andNVAR... .. ....... 93 B-4 Sample Output .. .. .. .... ..... ..... ..... 94 Appendix C: Detailed Listings Degree by Degree

  11. A sequential solution for anisotropic total variation image denoising with interval constraints

    NASA Astrophysics Data System (ADS)

    Xu, Jingyan; Noo, Frédéric

    2017-09-01

    We show that two problems involving the anisotropic total variation (TV) and interval constraints on the unknown variables admit, under some conditions, a simple sequential solution. Problem 1 is a constrained TV penalized image denoising problem; problem 2 is a constrained fused lasso signal approximator. The sequential solution entails finding first the solution to the unconstrained problem, and then applying a thresholding to satisfy the constraints. If the interval constraints are uniform, this sequential solution solves problem 1. If the interval constraints furthermore contain zero, the sequential solution solves problem 2. Here uniform interval constraints refer to all unknowns being constrained to the same interval. A typical example of application is image denoising in x-ray CT, where the image intensities are non-negative as they physically represent linear attenuation coefficient in the patient body. Our results are simple yet seem unknown; we establish them using the Karush-Kuhn-Tucker conditions for constrained convex optimization.

  12. Inter-Pregnancy Intervals and Maternal Morbidity: New Evidence from Rwanda.

    PubMed

    Habimana-Kabano, Ignace; Broekhuis, Annelet; Hooimeijer, Pieter

    2015-09-01

    The effects of short and long pregnancy intervals on maternal morbidity have hardly been investigated. This research analyses these effects using logistic regression in two steps. First, data from the Rwanda Demographic and Health Survey 2010 are used to study delivery referrals to District hospitals. Second, Kibagabaga District Hospital's maternity records are used to study the effect of inter-pregnancy intervals on maternal morbidity. The results show that both short and long intervals lead to higher odds of being referred because of pregnancy or delivery complications. Once admitted, short intervals were not associated with higher levels of maternal morbidity. Long intervals are associated with higher risks of third trimester bleeding, premature rupture of membrane and lower limb edema, while a higher age at conception is associated with lower risks. Poor women from rural areas and with limited health insurance are less often admitted to a hospital, which might bias the results.

  13. Resonant ultrasound spectroscopy

    DOEpatents

    Migliori, Albert

    1991-01-01

    A resonant ultrasound spectroscopy method provides a unique characterization of an object for use in distinguishing similar objects having physical differences greater than a predetermined tolerance. A resonant response spectrum is obtained for a reference object by placing excitation and detection transducers at any accessible location on the object. The spectrum is analyzed to determine the number of resonant response peaks in a predetermined frequency interval. The distribution of the resonance frequencies is then characterized in a manner effective to form a unique signature of the object. In one characterization, a small frequency interval is defined and stepped though the spectrum frequency range. Subsequent objects are similarly characterized where the characterizations serve as signatures effective to distinguish objects that differ from the reference object by more than the predetermined tolerance.

  14. A long time span relativistic precession model of the Earth

    NASA Astrophysics Data System (ADS)

    Tang, Kai; Soffel, Michael H.; Tao, Jin-He; Han, Wen-Biao; Tang, Zheng-Hong

    2015-04-01

    A numerical solution to the Earth's precession in a relativistic framework for a long time span is presented here. We obtain the motion of the solar system in the Barycentric Celestial Reference System by numerical integration with a symplectic integrator. Special Newtonian corrections accounting for tidal dissipation are included in the force model. The part representing Earth's rotation is calculated in the Geocentric Celestial Reference System by integrating the post-Newtonian equations of motion published by Klioner et al. All the main relativistic effects are included following Klioner et al. In particular, we consider several relativistic reference systems with corresponding time scales, scaled constants and parameters. Approximate expressions for Earth's precession in the interval ±1 Myr around J2000.0 are provided. In the interval ±2000 years around J2000.0, the difference compared to the P03 precession theory is only several arcseconds and the results are consistent with other long-term precession theories. Supported by the National Natural Science Foundation of China.

  15. Whole Blood Cholinesterase Activity in 20 Species of Wild Birds.

    PubMed

    Horowitz, Igal H; Yanco, Esty G; Landau, Shmulik; Nadler-Valency, Rona; Anglister, Nili; Bueller-Rosenzweig, Ariela; Apelbom-Halbersberg, Tal; Cuneah, Olga; Hanji, Vera; Bellaiche, Michel

    2016-06-01

    Clinical signs of organophosphate and carbamate intoxication in wild birds can be mistaken for those of other diseases, thus potentially delaying diagnosis and implementation of life-saving treatment. The objective of this study was to determine the reference interval for blood cholinesterase activity in 20 different wild avian species from 7 different orders, thereby compiling a reference database for wildlife veterinarians. Blood was collected from birds not suspected of having organophosphate or carbamate toxicosis, and the modified Michel method, which determines the change in blood pH that directly correlates with cholinesterase activity, was used to measure blood cholinesterase levels. Results of change in blood pH values ranged from 0.11 for the white-tailed eagle ( Haliaeetus albicilla ) to 0.90 for the honey buzzard ( Pernis apivorus ). The results showed that even within the same family, interspecies differences in normal cholinesterase blood activity were not uncommon. The findings emphasized the importance of determining reference intervals for avian blood cholinesterase activity at the species level.

  16. Interpregnancy Interval and Adverse Pregnancy Outcomes: An Analysis of Successive Pregnancies.

    PubMed

    Hanley, Gillian E; Hutcheon, Jennifer A; Kinniburgh, Brooke A; Lee, Lily

    2017-03-01

    To examine the association between interpregnancy interval and maternal-neonate health when matching women to their successive pregnancies to control for differences in maternal risk factors and compare these results with traditional unmatched designs. We conducted a retrospective cohort study of 38,178 women with three or more deliveries (two or greater interpregnancy intervals) between 2000 and 2015 in British Columbia, Canada. We examined interpregnancy interval (0-5, 6-11, 12-17, 18-23 [reference], 24-59, and 60 months or greater) in relation to neonatal outcomes (preterm birth [less than 37 weeks of gestation], small-for-gestational-age birth [less than the 10th centile], use of neonatal intensive care, low birth weight [less than 2,500 g]) and maternal outcomes (gestational diabetes, beginning the subsequent pregnancy obese [body mass index 30 or greater], and preeclampsia-eclampsia). We used conditional logistic regression to compare interpregnancy intervals within the same mother and unconditional (unmatched) logistic regression to enable comparison with prior research. Analyses using the traditional unmatched design showed significantly increased risks associated with short interpregnancy intervals (eg, there were 232 preterm births [12.8%] in 0-5 months compared with 501 [8.2%] in the 18-23 months reference group; adjusted odds ratio [OR] for preterm birth 1.53, 95% confidence interval [CI] 1.35-1.73). However, these risks were eliminated in within-woman matched analyses (adjusted OR for preterm birth 0.85, 95% CI 0.71-1.02). Matched results indicated that short interpregnancy intervals were significantly associated with increased risk of gestational diabetes (adjusted OR 1.35, 95% CI 1.02-1.80 for 0-5 months) and beginning the subsequent pregnancy obese (adjusted OR 1.61, 95% CI 1.05-2.45 for 0-5 months and adjusted OR 1.43, 95% CI 1.10-1.87 for 6-11 months). Previously reported associations between short interpregnancy intervals and adverse neonatal outcomes may not be causal. However, short interpregnancy interval is associated with increased risk of gestational diabetes and beginning a subsequent pregnancy obese.

  17. Ethnic variations in morbidity and mortality from lower respiratory tract infections: a retrospective cohort study

    PubMed Central

    Steiner, Markus FC; Cezard, Genevieve; Bansal, Narinder; Fischbacher, Colin; Douglas, Anne; Bhopal, Raj; Sheikh, Aziz

    2015-01-01

    Objective There is evidence of substantial ethnic variations in asthma morbidity and the risk of hospitalisation, but the picture in relation to lower respiratory tract infections is unclear. We carried out an observational study to identify ethnic group differences for lower respiratory tract infections. Design A retrospective, cohort study. Setting Scotland. Participants 4.65 million people on whom information was available from the 2001 census, followed from May 2001 to April 2010. Main outcome measures Hospitalisations and deaths (any time following first hospitalisation) from lower respiratory tract infections, adjusted risk ratios and hazard ratios by ethnicity and sex were calculated. We multiplied ratios and confidence intervals by 100, so the reference Scottish White population’s risk ratio and hazard ratio was 100. Results Among men, adjusted risk ratios for lower respiratory tract infection hospitalisation were lower in Other White British (80, 95% confidence interval 73–86) and Chinese (69, 95% confidence interval 56–84) populations and higher in Pakistani groups (152, 95% confidence interval 136–169). In women, results were mostly similar to those in men (e.g. Chinese 68, 95% confidence interval 56–82), although higher adjusted risk ratios were found among women of the Other South Asians group (145, 95% confidence interval 120–175). Survival (adjusted hazard ratio) following lower respiratory tract infection for Pakistani men (54, 95% confidence interval 39–74) and women (31, 95% confidence interval 18–53) was better than the reference population. Conclusions Substantial differences in the rates of lower respiratory tract infections amongst different ethnic groups in Scotland were found. Pakistani men and women had particularly high rates of lower respiratory tract infection hospitalisation. The reasons behind the high rates of lower respiratory tract infection in the Pakistani community are now required. PMID:26152675

  18. Diagnostic accuracy of the Amsler grid and the preferential hyperacuity perimetry in the screening of patients with age-related macular degeneration: systematic review and meta-analysis.

    PubMed

    Faes, L; Bodmer, N S; Bachmann, L M; Thiel, M A; Schmid, M K

    2014-07-01

    To clarify the screening potential of the Amsler grid and preferential hyperacuity perimetry (PHP) in detecting or ruling out wet age-related macular degeneration (AMD). Medline, Scopus and Web of Science (by citation of reference) were searched. Checking of reference lists of review articles and of included articles complemented electronic searches. Papers were selected, assessed, and extracted in duplicate. Systematic review and meta-analysis. Twelve included studies enrolled 903 patients and allowed constructing 27 two-by-two tables. Twelve tables reported on the Amsler grid and its modifications, twelve tables reported on the PHP, one table assessed the MCPT and two tables assessed the M-charts. All but two studies had a case-control design. The pooled sensitivity of studies assessing the Amsler grid was 0.78 (95% confidence intervals; 0.64-0.87), and the pooled specificity was 0.97 (95% confidence intervals; 0.91-0.99). The corresponding positive and negative likelihood ratios were 23.1 (95% confidence intervals; 8.4-64.0) and 0.23 (95% confidence intervals; 0.14-0.39), respectively. The pooled sensitivity of studies assessing the PHP was 0.85 (95% confidence intervals; 0.80-0.89), and specificity was 0.87 (95% confidence intervals; 0.82-0.91). The corresponding positive and negative likelihood ratios were 6.7 (95% confidence intervals; 4.6-9.8) and 0.17 (95% confidence intervals; 0.13-0.23). No pooling was possible for MCPT and M-charts. Results from small preliminary studies show promising test performance characteristics both for the Amsler grid and PHP to rule out wet AMD in the screening setting. To what extent these findings can be transferred to a real clinic practice still needs to be established.

  19. Reference interval computation: which method (not) to choose?

    PubMed

    Pavlov, Igor Y; Wilson, Andrew R; Delgado, Julio C

    2012-07-11

    When different methods are applied to reference interval (RI) calculation the results can sometimes be substantially different, especially for small reference groups. If there are no reliable RI data available, there is no way to confirm which method generates results closest to the true RI. We randomly drawn samples obtained from a public database for 33 markers. For each sample, RIs were calculated by bootstrapping, parametric, and Box-Cox transformed parametric methods. Results were compared to the values of the population RI. For approximately half of the 33 markers, results of all 3 methods were within 3% of the true reference value. For other markers, parametric results were either unavailable or deviated considerably from the true values. The transformed parametric method was more accurate than bootstrapping for sample size of 60, very close to bootstrapping for sample size 120, but in some cases unavailable. We recommend against using parametric calculations to determine RIs. The transformed parametric method utilizing Box-Cox transformation would be preferable way of RI calculation, if it satisfies normality test. If not, the bootstrapping is always available, and is almost as accurate and precise as the transformed parametric method. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Hematological reference values of healthy Malaysian population.

    PubMed

    Roshan, T M; Rosline, H; Ahmed, S A; Rapiaah, M; Wan Zaidah, A; Khattak, M N

    2009-10-01

    Health and disease can only be distinguished by accurate and reliable reference values of a particular laboratory test. It is now a proven fact that there is considerable variation in hematology reference intervals depending on the demographic and preanalytical variables. There are evidences that values provided by manufacturers do not have appropriate application for all populations. Moreover, reference ranges provided by different laboratory manuals and books also do not solve this problem. We are presenting here normal reference ranges of Malaysian population. These values were determined by using Sysmex XE-2100 and ACL 9000 hematology and coagulation analyzers. Results from this study showed that there were considerable differences in the reference values from manufacturers, western population or laboratory manuals compared with those from the local population.

  1. Development of Procedures for Computing Site Seismicity

    DTIC Science & Technology

    1993-02-01

    surface wave magnitude when in the range of 5 to 7.5. REFERENCES Ambraseys, N.N. (1970). "Some characteristic features of the Anatolian fault zone...geology seismicity and environmental impact, Association of Engineering Geologists , Special Publication. Los Angeles, CA, University Publishers, 1973... Geologists ) Recurrenc.e Recurrence Slip Intervals (yr) at Intervals (yr) over Fault Rate Length a Point on Fault Length of Fault (cm/yI) (km) (Rý) (R

  2. Recent meta-analyses neglect previous systematic reviews and meta-analyses about the same topic: a systematic examination.

    PubMed

    Helfer, Bartosz; Prosser, Aaron; Samara, Myrto T; Geddes, John R; Cipriani, Andrea; Davis, John M; Mavridis, Dimitris; Salanti, Georgia; Leucht, Stefan

    2015-04-14

    As the number of systematic reviews is growing rapidly, we systematically investigate whether meta-analyses published in leading medical journals present an outline of available evidence by referring to previous meta-analyses and systematic reviews. We searched PubMed for recent meta-analyses of pharmacological treatments published in high impact factor journals. Previous systematic reviews and meta-analyses were identified with electronic searches of keywords and by searching reference sections. We analyzed the number of meta-analyses and systematic reviews that were cited, described and discussed in each recent meta-analysis. Moreover, we investigated publication characteristics that potentially influence the referencing practices. We identified 52 recent meta-analyses and 242 previous meta-analyses on the same topics. Of these, 66% of identified previous meta-analyses were cited, 36% described, and only 20% discussed by recent meta-analyses. The probability of citing a previous meta-analysis was positively associated with its publication in a journal with a higher impact factor (odds ratio, 1.49; 95% confidence interval, 1.06 to 2.10) and more recent publication year (odds ratio, 1.19; 95% confidence interval 1.03 to 1.37). Additionally, the probability of a previous study being described by the recent meta-analysis was inversely associated with the concordance of results (odds ratio, 0.38; 95% confidence interval, 0.17 to 0.88), and the probability of being discussed was increased for previous studies that employed meta-analytic methods (odds ratio, 32.36; 95% confidence interval, 2.00 to 522.85). Meta-analyses on pharmacological treatments do not consistently refer to and discuss findings of previous meta-analyses on the same topic. Such neglect can lead to research waste and be confusing for readers. Journals should make the discussion of related meta-analyses mandatory.

  3. Automated saliva processing for LC-MS/MS: Improving laboratory efficiency in cortisol and cortisone testing.

    PubMed

    Antonelli, Giorgia; Padoan, Andrea; Artusi, Carlo; Marinova, Mariela; Zaninotto, Martina; Plebani, Mario

    2016-04-01

    The aim of this study was to implement in our routine practice an automated saliva preparation protocol for quantification of cortisol (F) and cortisone (E) by LC-MS/MS using a liquid handling platform, maintaining the previously defined reference intervals with the manual preparation. Addition of internal standard solution to saliva samples and calibrators and SPE on μ-elution 96-well plate were performed by liquid handling platform. After extraction, the eluates were submitted to LC-MS/MS analysis. The manual steps within the entire process were to transfer saliva samples in suitable tubes, to put the cap mat and transfer of the collection plate to the LC auto sampler. Transference of the reference intervals from the manual to the automated procedure was established by Passing Bablok regression on 120 saliva samples analyzed simultaneously with the two procedures. Calibration curves were linear throughout the selected ranges. The imprecision ranged from 2 to 10%, with recoveries from 95 to 116%. Passing Bablok regression demonstrated no significant bias. The liquid handling platform translates the manual steps into automated operations allowing for saving hands-on time, while maintaining assay reproducibility and ensuring reliability of results, making it implementable in our routine with the previous established reference intervals. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. Clinical Chemistry Reference Intervals for C57BL/6J, C57BL/6N, and C3HeB/FeJ Mice (Mus musculus)

    PubMed Central

    Otto, Gordon P; Rathkolb, Birgit; Oestereicher, Manuela A; Lengger, Christoph J; Moerth, Corinna; Micklich, Kateryna; Fuchs, Helmut; Gailus-Durner, Valérie; Wolf, Eckhard; de Angelis, Martin Hrabě

    2016-01-01

    Although various mouse inbred strains are widely used to investigate disease mechanisms and to establish new therapeutic strategies, sex-specific reference intervals for laboratory diagnostic analytes that are generated from large numbers of animals have been unavailable. In this retrospective study, we screened data from more than 12,000 mice phenotyped in the German Mouse Clinic from January 2006 through June 2014 and selected animals with the genetic background of C57BL/6J, C57BL/6N, or C3HeB/FeJ. In addition, we distinguished between the C57BL/6NTac substrain and C57BL/6N mice received from other vendors. The corresponding data sets of electrolytes (sodium, potassium, calcium, chloride, inorganic phosphate), lipids (cholesterol, triglyceride), and enzyme activities (ALT, AST, ALP, α-amylase) and urea, albumin, and total protein levels were analyzed. Significant effects of age and sex on these analytes were identified, and strain- or substrain- and sex-specific reference intervals for 90- to 135-d-old mice were calculated. In addition, we include an overview of the literature that reports clinical chemistry values for wild-type mice of different strains. Our results support researchers interpreting clinical chemistry values from various mouse mutants and corresponding wild-type controls based on the examined strains and substrains. PMID:27423143

  5. Clinical Chemistry Reference Intervals for C57BL/6J, C57BL/6N, and C3HeB/FeJ Mice (Mus musculus).

    PubMed

    Otto, Gordon P; Rathkolb, Birgit; Oestereicher, Manuela A; Lengger, Christoph J; Moerth, Corinna; Micklich, Kateryna; Fuchs, Helmut; Gailus-Durner, Valérie; Wolf, Eckhard; Hrabě de Angelis, Martin

    2016-01-01

    Although various mouse inbred strains are widely used to investigate disease mechanisms and to establish new therapeutic strategies, sex-specific reference intervals for laboratory diagnostic analytes that are generated from large numbers of animals have been unavailable. In this retrospective study, we screened data from more than 12,000 mice phenotyped in the German Mouse Clinic from January 2006 through June 2014 and selected animals with the genetic background of C57BL/6J, C57BL/6N, or C3HeB/FeJ. In addition, we distinguished between the C57BL/6NTac substrain and C57BL/6N mice received from other vendors. The corresponding data sets of electrolytes (sodium, potassium, calcium, chloride, inorganic phosphate), lipids (cholesterol, triglyceride), and enzyme activities (ALT, AST, ALP, α-amylase) and urea, albumin, and total protein levels were analyzed. Significant effects of age and sex on these analytes were identified, and strain- or substrain- and sex-specific reference intervals for 90- to 135-d-old mice were calculated. In addition, we include an overview of the literature that reports clinical chemistry values for wild-type mice of different strains. Our results support researchers interpreting clinical chemistry values from various mouse mutants and corresponding wild-type controls based on the examined strains and substrains.

  6. Reference intervals, longitudinal analyses, and index of individuality of commonly measured laboratory variables in captive bald eagles (Haliaeetus leucocephalus).

    PubMed

    Jones, Michael P; Arheart, Kristopher L; Cray, Carolyn

    2014-06-01

    The objectives of this study were to determine reference intervals, perform longitudinal analyses, and determine the index of individuality (IoI) of 8 hematologic, and 13 biochemical and electrophoretic variables for a group of captive bald eagles (Haliaeetus leucocephalus). Reference intervals were determined from blood samples collected during annual wellness examinations for 41 eagles (23 male and 18 female) with ages ranging between 6 and 43 years (18.7 +/- 7.4, mean +/- SD) at the time of sample collection. Longitudinal analyses and IoI were determined for measured hematologic, biochemical, and protein electrophoretic variables, both individually and as a group, for a subset of 16 eagles (10 male and 6 female) during a 12-year period. This smaller group of eagles ranged in age between 2 and 20 years at the start of the study period, and between 14 and 32 years (21.9 +/- 5.0, mean +/- SD) at the end of the study period. Significant increases with age within the group of 16 eagles were observed only for red blood cells, percent heterophils, total protein, and beta-globulin protein fraction, while albumin:globulin decreased significantly with age. A low IoI (> or = 1.4) was determined for all hematologic and biochemical variables except gamma globulins, which had high IoI (< or = 0.6) for 3 individuals within the subset of 16.

  7. Pyroglutamate (5-oxoproline) measured with hydrophilic interaction chromatography (HILIC) tandem mass spectrometry in acutely ill patients.

    PubMed

    Pretorius, Carel J; Reade, Michael C; Warnholtz, Chris; McWhinney, Brett; Phua, Meng Mei; Lipman, Jeffrey; Ungerer, Jacobus P J

    2017-03-01

    Pyroglutamic acid (PGA) is challenging to quantify in plasma and is a rare cause of metabolic acidosis that is associated with inherited disorders or acquired after exposure to drugs. We developed a hydrophilic interaction liquid chromatography tandem mass spectrometry method with a short analysis time. We established a reference interval and then measured PGA in acutely ill patients to investigate associations with clinical, pharmaceutical and laboratory parameters. The assay limit of the blank was 0.14μmol/L and was linear to 5000μmol/L with good precision. In-source formation of PGA from glutamate and glutamine was avoided by chromatographic separation. The PGA in controls had a reference interval of 22.6 to 47.8μmol/L. The median PGA concentration in acutely ill patients was similar (P=0.21), but 18 individuals were above the reference interval with concentrations up to 250μmol/L. We detected an association between PGA concentration and antibiotic and acetaminophen administration as well as renal impairment and severity of illness. Elevations of PGA in this unselected cohort were small compared to those reported in patients with pyroglutamic acidosis. The method is suitable for routine clinical use. We confirmed several expected associations with PGA in an acutely ill population. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  8. Plasma biochemical and PCV ranges for healthy, wild, immature hawksbill (Eretmochelys imbricata) sea turtles.

    PubMed

    Whiting, S D; Guinea, M L; Fomiatti, K; Flint, M; Limpus, C J

    2014-06-14

    In recent years, the use of blood chemistry as a diagnostic tool for sea turtles has been demonstrated, but much of its effectiveness relies on reference intervals. The first comprehensive blood chemistry values for healthy wild hawksbill (Eretmochelys imbricata) sea turtles are presented. Nineteen blood chemistry analytes and packed cell volume were analysed for 40 clinically healthy juvenile hawksbill sea turtles captured from a rocky reef habitat in northern Australia. We used four statistical approaches to calculate reference intervals and to investigate their use with non-normal distributions and small sample sizes, and to compare upper and lower limits between methods. Eleven analytes were correlated with curved carapace length indicating that body size should be considered when designing future studies and interpreting analyte values. British Veterinary Association.

  9. Event- and interval-based measurement of stuttering: a review.

    PubMed

    Valente, Ana Rita S; Jesus, Luis M T; Hall, Andreia; Leahy, Margaret

    2015-01-01

    Event- and interval-based measurements are two different ways of computing frequency of stuttering. Interval-based methodology emerged as an alternative measure to overcome problems associated with reproducibility in the event-based methodology. No review has been made to study the effect of methodological factors in interval-based absolute reliability data or to compute the agreement between the two methodologies in terms of inter-judge, intra-judge and accuracy (i.e., correspondence between raters' scores and an established criterion). To provide a review related to reproducibility of event-based and time-interval measurement, and to verify the effect of methodological factors (training, experience, interval duration, sample presentation order and judgment conditions) on agreement of time-interval measurement; in addition, to determine if it is possible to quantify the agreement between the two methodologies The first two authors searched for articles on ERIC, MEDLINE, PubMed, B-on, CENTRAL and Dissertation Abstracts during January-February 2013 and retrieved 495 articles. Forty-eight articles were selected for review. Content tables were constructed with the main findings. Articles related to event-based measurements revealed values of inter- and intra-judge greater than 0.70 and agreement percentages beyond 80%. The articles related to time-interval measures revealed that, in general, judges with more experience with stuttering presented significantly higher levels of intra- and inter-judge agreement. Inter- and intra-judge values were beyond the references for high reproducibility values for both methodologies. Accuracy (regarding the closeness of raters' judgements with an established criterion), intra- and inter-judge agreement were higher for trained groups when compared with non-trained groups. Sample presentation order and audio/video conditions did not result in differences in inter- or intra-judge results. A duration of 5 s for an interval appears to be an acceptable agreement. Explanation for high reproducibility values as well as parameter choice to report those data are discussed. Both interval- and event-based methodologies used trained or experienced judges for inter- and intra-judge determination and data were beyond the references for good reproducibility values. Inter- and intra-judge values were reported in different metric scales among event- and interval-based methods studies, making it unfeasible to quantify the agreement between the two methods. © 2014 Royal College of Speech and Language Therapists.

  10. Alternative Confidence Interval Methods Used in the Diagnostic Accuracy Studies

    PubMed Central

    Gülhan, Orekıcı Temel

    2016-01-01

    Background/Aim. It is necessary to decide whether the newly improved methods are better than the standard or reference test or not. To decide whether the new diagnostics test is better than the gold standard test/imperfect standard test, the differences of estimated sensitivity/specificity are calculated with the help of information obtained from samples. However, to generalize this value to the population, it should be given with the confidence intervals. The aim of this study is to evaluate the confidence interval methods developed for the differences between the two dependent sensitivity/specificity values on a clinical application. Materials and Methods. In this study, confidence interval methods like Asymptotic Intervals, Conditional Intervals, Unconditional Interval, Score Intervals, and Nonparametric Methods Based on Relative Effects Intervals are used. Besides, as clinical application, data used in diagnostics study by Dickel et al. (2010) has been taken as a sample. Results. The results belonging to the alternative confidence interval methods for Nickel Sulfate, Potassium Dichromate, and Lanolin Alcohol are given as a table. Conclusion. While preferring the confidence interval methods, the researchers have to consider whether the case to be compared is single ratio or dependent binary ratio differences, the correlation coefficient between the rates in two dependent ratios and the sample sizes. PMID:27478491

  11. Alternative Confidence Interval Methods Used in the Diagnostic Accuracy Studies.

    PubMed

    Erdoğan, Semra; Gülhan, Orekıcı Temel

    2016-01-01

    Background/Aim. It is necessary to decide whether the newly improved methods are better than the standard or reference test or not. To decide whether the new diagnostics test is better than the gold standard test/imperfect standard test, the differences of estimated sensitivity/specificity are calculated with the help of information obtained from samples. However, to generalize this value to the population, it should be given with the confidence intervals. The aim of this study is to evaluate the confidence interval methods developed for the differences between the two dependent sensitivity/specificity values on a clinical application. Materials and Methods. In this study, confidence interval methods like Asymptotic Intervals, Conditional Intervals, Unconditional Interval, Score Intervals, and Nonparametric Methods Based on Relative Effects Intervals are used. Besides, as clinical application, data used in diagnostics study by Dickel et al. (2010) has been taken as a sample. Results. The results belonging to the alternative confidence interval methods for Nickel Sulfate, Potassium Dichromate, and Lanolin Alcohol are given as a table. Conclusion. While preferring the confidence interval methods, the researchers have to consider whether the case to be compared is single ratio or dependent binary ratio differences, the correlation coefficient between the rates in two dependent ratios and the sample sizes.

  12. Method and apparatus for frequency spectrum analysis

    NASA Technical Reports Server (NTRS)

    Cole, Steven W. (Inventor)

    1992-01-01

    A method for frequency spectrum analysis of an unknown signal in real-time is discussed. The method is based upon integration of 1-bit samples of signal voltage amplitude corresponding to sine or cosine phases of a controlled center frequency clock which is changed after each integration interval to sweep the frequency range of interest in steps. Integration of samples during each interval is carried out over a number of cycles of the center frequency clock spanning a number of cycles of an input signal to be analyzed. The invention may be used to detect the frequency of at least two signals simultaneously. By using a reference signal of known frequency and voltage amplitude (added to the two signals for parallel processing in the same way, but in a different channel with a sampling at the known frequency and phases of the reference signal), the absolute voltage amplitude of the other two signals may be determined by squaring the sine and cosine integrals of each channel and summing the squares to obtain relative power measurements in all three channels and, from the known voltage amplitude of the reference signal, obtaining an absolute voltage measurement for the other two signals by multiplying the known voltage of the reference signal with the ratio of the relative power of each of the other two signals to the relative power of the reference signal.

  13. The Effect of Geographic Location on Circannual Adrenocorticotropic Hormone Plasma Concentrations in Horses in Australia.

    PubMed

    Secombe, C J; Tan, R H H; Perara, D I; Byrne, D P; Watts, S P; Wearn, J G

    2017-09-01

    Longitudinal evaluation of plasma endogenous ACTH concentration in clinically normal horses has not been investigated in the Southern Hemisphere. To longitudinally determine monthly upper reference limits for plasma ACTH in 2 disparate Australian geographic locations and to examine whether location affected the circannual rhythm of endogenous ACTH in the 2 groups of horses over a 12-month period. Clinically normal horses <20 years of age from 4 properties (institutional herd and client owned animals) in Perth (n = 40) and Townsville (n = 41) were included in the study. A prospective longitudinal descriptive study to determine the upper reference limit and confidence intervals for plasma ACTH in each geographic location using the ASVCP reference interval (RI) guidelines, for individual months and monthly groupings for 12 consecutive months. Plasma endogenous ACTH concentrations demonstrated a circannual rhythm. The increase in endogenous ACTH was not confined to the autumnal months but was associated with changes in photoperiod. During the quiescent period, plasma ACTH concentrations were lower, ≤43 pg/mL (upper limit of the 90% confidence interval (CI)) in horses from Perth and ≤67 pg/mL (upper limit of the 90% CI) in horses from Townsville, than at the acrophase, ≤94 pg/mL (upper limit of the 90% CI) in horses from Perth, ≤101 pg/mL (upper limit of the 90% CI) in horses from Townsville. Circannual rhythms of endogenous ACTH concentrations vary between geographic locations, this could be due to changes in photoperiod or other unknown factors, and upper reference limits should be determined for specific locations. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  14. An appraisal of statistical procedures used in derivation of reference intervals.

    PubMed

    Ichihara, Kiyoshi; Boyd, James C

    2010-11-01

    When conducting studies to derive reference intervals (RIs), various statistical procedures are commonly applied at each step, from the planning stages to final computation of RIs. Determination of the necessary sample size is an important consideration, and evaluation of at least 400 individuals in each subgroup has been recommended to establish reliable common RIs in multicenter studies. Multiple regression analysis allows identification of the most important factors contributing to variation in test results, while accounting for possible confounding relationships among these factors. Of the various approaches proposed for judging the necessity of partitioning reference values, nested analysis of variance (ANOVA) is the likely method of choice owing to its ability to handle multiple groups and being able to adjust for multiple factors. Box-Cox power transformation often has been used to transform data to a Gaussian distribution for parametric computation of RIs. However, this transformation occasionally fails. Therefore, the non-parametric method based on determination of the 2.5 and 97.5 percentiles following sorting of the data, has been recommended for general use. The performance of the Box-Cox transformation can be improved by introducing an additional parameter representing the origin of transformation. In simulations, the confidence intervals (CIs) of reference limits (RLs) calculated by the parametric method were narrower than those calculated by the non-parametric approach. However, the margin of difference was rather small owing to additional variability in parametrically-determined RLs introduced by estimation of parameters for the Box-Cox transformation. The parametric calculation method may have an advantage over the non-parametric method in allowing identification and exclusion of extreme values during RI computation.

  15. The prognostic value of standardized reference values for speckle-tracking global longitudinal strain in hypertrophic cardiomyopathy.

    PubMed

    Hartlage, Gregory R; Kim, Jonathan H; Strickland, Patrick T; Cheng, Alan C; Ghasemzadeh, Nima; Pernetz, Maria A; Clements, Stephen D; Williams, B Robinson

    2015-03-01

    Speckle-tracking left ventricular global longitudinal strain (GLS) assessment may provide substantial prognostic information for hypertrophic cardiomyopathy (HCM) patients. Reference values for GLS have been recently published. We aimed to evaluate the prognostic value of standardized reference values for GLS in HCM patients. An analysis of HCM clinic patients who underwent GLS was performed. GLS was defined as normal (more negative or equal to -16%) and abnormal (less negative than -16%) based on recently published reference values. Patients were followed for a composite of events including heart failure hospitalization, sustained ventricular arrhythmia, and all-cause death. The power of GLS to predict outcomes was assessed relative to traditional clinical and echocardiographic variables present in HCM. 79 HCM patients were followed for a median of 22 months (interquartile range 9-30 months) after imaging. During follow-up, 15 patients (19%) met the primary outcome. Abnormal GLS was the only echocardiographic variable independently predictive of the primary outcome [multivariate Hazard ratio 5.05 (95% confidence interval 1.09-23.4, p = 0.038)]. When combined with traditional clinical variables, abnormal GLS remained independently predictive of the primary outcome [multivariate Hazard ratio 5.31 (95 % confidence interval 1.18-24, p = 0.030)]. In a model including the strongest clinical and echocardiographic predictors of the primary outcome, abnormal GLS demonstrated significant incremental benefit for risk stratification [net reclassification improvement 0.75 (95 % confidence interval 0.21-1.23, p < 0.0001)]. Abnormal GLS is an independent predictor of adverse outcomes in HCM patients. Standardized use of GLS may provide significant incremental value over traditional variables for risk stratification.

  16. [Effect of pazufloxacin mesilate, a new quinolone antibacterial agent, for intravenous use on QT interval].

    PubMed

    Fukuda, Hitoshi; Morita, Yukie; Shiotani, Norio; Mizuo, Midori; Komae, Norihisa

    2004-08-01

    The potential for QT interval prolongation of pazufloxacin mesilate (PZFX mesilate), a new quinolone antibacterial agent for intravenous use, was investigated by in vitro and in vivo electrophysiology studies. Following results were obtained. In vitro electrophysiology study using guinea pig papillary muscles: PZFX mesilate (30-300 microM) had no effects on resting membrane potential (RMP), action potential amplitude (APA) and action potential duration (APD). Reference quinolones, sparfloxacin (3-30 microM) and moxifloxacin (10-100 microM), had no effects on RMP and APA, but significantly prolonged APD at more than 3 and 10 microM, respectively, while ciprofloxacin (10-100 microM) had no effect on each parameter. In vivo electrophysiology study using anesthetized dogs: PZFX mesilate had no effects on electrocardiograph parameter (PR interval, QRS interval, QT interval and QTc) after intravenous administration of 3-30 mg/kg. These results suggest that PZFX mesilate has low potential for QT interval prolongation.

  17. The cystatin C/creatinine ratio, a marker of glomerular filtration quality: associated factors, reference intervals, and prediction of morbidity and mortality in healthy seniors.

    PubMed

    Purde, Mette-Triin; Nock, Stefan; Risch, Lorenz; Medina Escobar, Pedro; Grebhardt, Chris; Nydegger, Urs E; Stanga, Zeno; Risch, Martin

    2016-03-01

    The ratio of cystatin C (cysC) to creatinine (crea) is regarded as a marker of glomerular filtration quality associated with cardiovascular morbidities. We sought to determine reference intervals for serum cysC-crea ratio in seniors. Furthermore, we sought to determine whether other low-molecular weight molecules exhibit a similar behavior in individuals with altered glomerular filtration quality. Finally, we investigated associations with adverse outcomes. A total of 1382 subjectively healthy Swiss volunteers aged 60 years or older were enrolled in the study. Reference intervals were calculated according to Clinical & Laboratory Standards Institute (CLSI) guideline EP28-A3c. After a baseline exam, a 4-year follow-up survey recorded information about overall morbidity and mortality. The cysC-crea ratio (mean 0.0124 ± 0.0026 mg/μmol) was significantly higher in women and increased progressively with age. Other associated factors were hemoglobin A1c, mean arterial pressure, and C-reactive protein (P < 0.05 for all). Participants exhibiting shrunken pore syndrome had significantly higher ratios of 3.5-66.5 kDa molecules (brain natriuretic peptide, parathyroid hormone, β2-microglobulin, cystatin C, retinol-binding protein, thyroid-stimulating hormone, α1-acid glycoprotein, lipase, amylase, prealbumin, and albumin) and creatinine. There was no such difference in the ratios of very low-molecular weight molecules (urea, uric acid) to creatinine or in the ratios of molecules larger than 66.5 kDa (transferrin, haptoglobin) to creatinine. The cysC-crea ratio was significantly predictive of mortality and subjective overall morbidity at follow-up in logistic regression models adjusting for several factors. The cysC-crea ratio exhibits age- and sex-specific reference intervals in seniors. In conclusion, the cysC-crea ratio may indicate the relative retention of biologically active low-molecular weight compounds and can independently predict the risk for overall mortality and morbidity in the elderly. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. A cross-sectional study measuring vanadium and chromium levels in paediatric patients with CKD

    PubMed Central

    Filler, Guido; Kobrzynski, Marta; Sidhu, Hargun Kaur; Belostotsky, Vladimir; Huang, Shih-Han S; McIntyre, Chris; Yang, Liju

    2017-01-01

    Objectives Although many secondary effects of high levels of vanadium (V) and chromium (Cr) overlap with symptoms seen in paediatric patients with chronic kidney disease (CKD), their plasma V and Cr levels are understudied. Design Ancillary cross-sectional study to a prospective, longitudinal, randomised controlled trial. Setting Children’s Hospital of Western Ontario, London Health Sciences Centre, London, Ontario, Canada. Participants 36 children and adolescents 4–18 years of age with CKD. Interventions 1–6 trace element measurements per patient. Cystatin C (CysC) estimated glomerular filtration rate (eGFR) was calculated using the Filler formula. Plasma V and Cr levels were measured using high-resolution sector field inductively coupled mass spectrometry. Anthropomorphic data and blood parameters were collected from our electronic chart programme. Water Cr and V data were obtained from the Ontario Water (Stream) Quality Monitoring Network. Primary and secondary outcome measures Primary outcomes: plasma Cr and V. Secondary outcomes: age, season, CysC, CysC eGFR, and Cr and V levels in environmental water. Results The median (IQR) eGFR was 51 mL/min/1.73 m2 (35, 75). The median V level was 0.12 µg/L (0.09, 0.18), which was significantly greater than the 97.5th percentile of the reference interval of 0.088 µg/L; 32 patients had at least one set of V levels above the published reference interval. The median Cr level was 0.43 µg/L (0.36, 0.54), which was also significantly greater than the established reference interval; 34 had at least one set of Cr levels above the published reference interval. V and Cr levels were moderately correlated. Only some patients had high environmental exposure. Conclusions Our study suggests that paediatric patients with CKD have elevated plasma levels of V and Cr. This may be the result of both environmental exposure and a low eGFR. It may be necessary to monitor V and Cr levels in patients with an eGFR <30 mL/min/1.73 m2. Trial registration number NCT02126293; HC#172241. PMID:28592575

  19. Blood analytes of oceanic-juvenile loggerhead sea turtles (Caretta caretta) from Azorean waters: reference intervals, size-relevant correlations and comparisons to neritic loggerheads from western Atlantic coastal waters.

    PubMed

    Stacy, Nicole I; Bjorndal, Karen A; Perrault, Justin R; Martins, Helen R; Bolten, Alan B

    2018-01-01

    Blood analyte reference intervals are scarce for immature life stages of the loggerhead sea turtle ( Caretta caretta ). The objectives of this study were to (1) document reference intervals of packed cell volume (PCV) and 20 plasma chemistry analytes from wild oceanic-juvenile stage loggerhead turtles from Azorean waters, (2) investigate correlations with body size (minimum straight carapace length: SCL min ) and (3) compare plasma chemistry data to those from older, larger neritic juveniles (<80 cm SCL min ) and adult loggerheads (≥80 cm SCL min ) that have recruited to the West Atlantic in waters around Cape Canaveral, Florida. Twenty-eight Azorean loggerhead turtles with SCL min of 17.6-60.0 cm (mean 34.9 ± 12.1 cm) were captured, sampled and immediately released. Reference intervals are reported. There were several biologically relevant correlations of blood analytes with SCL min : positive correlations of PCV, proteins and triglycerides with SCL min indicated somatic growth, increasing diving activity and/or diet; negative correlations of tissue enzymes with SCL min suggested faster growth at smaller turtle size, while negative correlations of electrolytes with SCL min indicated differences in diet, environmental conditions and/or osmoregulation unique to the geographic location. Comparisons of loggerhead turtles from the Azores (i.e. oceanic) and Cape Canaveral (i.e. neritic) identified significant differences regarding diet, somatic growth, and/or environment: in Azorean turtles, albumin, triglycerides and bilirubin increased with SCL min , while alkaline phosphatase, lactate dehydrogenase and sodium decreased. In larger neritic Cape Canaveral turtles, aspartate aminotransferase increased with SCL min , while the albumin:globulin ratio, phosphorus and cholesterol decreased. These differences suggest unique physiological disparities between life stage development and migration, reflecting biological and habitat differences between the two populations. This information presents biologically important data that is applicable to stranded individual turtles and to the population level, a tool for the development of conservation strategies, and a baseline for future temporal and spatial investigations of the Azorean loggerhead sea turtle population.

  20. Blood analytes of oceanic-juvenile loggerhead sea turtles (Caretta caretta) from Azorean waters: reference intervals, size-relevant correlations and comparisons to neritic loggerheads from western Atlantic coastal waters

    PubMed Central

    Bjorndal, Karen A; Perrault, Justin R; Martins, Helen R; Bolten, Alan B

    2018-01-01

    Abstract Blood analyte reference intervals are scarce for immature life stages of the loggerhead sea turtle (Caretta caretta). The objectives of this study were to (1) document reference intervals of packed cell volume (PCV) and 20 plasma chemistry analytes from wild oceanic-juvenile stage loggerhead turtles from Azorean waters, (2) investigate correlations with body size (minimum straight carapace length: SCLmin) and (3) compare plasma chemistry data to those from older, larger neritic juveniles (<80 cm SCLmin) and adult loggerheads (≥80 cm SCLmin) that have recruited to the West Atlantic in waters around Cape Canaveral, Florida. Twenty-eight Azorean loggerhead turtles with SCLmin of 17.6–60.0 cm (mean 34.9 ± 12.1 cm) were captured, sampled and immediately released. Reference intervals are reported. There were several biologically relevant correlations of blood analytes with SCLmin: positive correlations of PCV, proteins and triglycerides with SCLmin indicated somatic growth, increasing diving activity and/or diet; negative correlations of tissue enzymes with SCLmin suggested faster growth at smaller turtle size, while negative correlations of electrolytes with SCLmin indicated differences in diet, environmental conditions and/or osmoregulation unique to the geographic location. Comparisons of loggerhead turtles from the Azores (i.e. oceanic) and Cape Canaveral (i.e. neritic) identified significant differences regarding diet, somatic growth, and/or environment: in Azorean turtles, albumin, triglycerides and bilirubin increased with SCLmin, while alkaline phosphatase, lactate dehydrogenase and sodium decreased. In larger neritic Cape Canaveral turtles, aspartate aminotransferase increased with SCLmin, while the albumin:globulin ratio, phosphorus and cholesterol decreased. These differences suggest unique physiological disparities between life stage development and migration, reflecting biological and habitat differences between the two populations. This information presents biologically important data that is applicable to stranded individual turtles and to the population level, a tool for the development of conservation strategies, and a baseline for future temporal and spatial investigations of the Azorean loggerhead sea turtle population. PMID:29479433

  1. Association of vascular risk factors with cervical artery dissection and ischemic stroke in young adults.

    PubMed

    Debette, Stéphanie; Metso, Tiina; Pezzini, Alessandro; Abboud, Shérine; Metso, Antti; Leys, Didier; Bersano, Anna; Louillet, Fabien; Caso, Valeria; Lamy, Chantal; Medeiros, Elisabeth; Samson, Yves; Grond-Ginsbach, Caspar; Engelter, Stefan T; Thijs, Vincent; Beretta, Simone; Béjot, Yannick; Sessa, Maria; Lorenza Muiesan, Maria; Amouyel, Philippe; Castellano, Maurizio; Arveiler, Dominique; Tatlisumak, Turgut; Dallongeville, Jean

    2011-04-12

    Little is known about the risk factors for cervical artery dissection (CEAD), a major cause of ischemic stroke (IS) in young adults. Hypertension, diabetes mellitus, smoking, hypercholesterolemia, and obesity are important risk factors for IS. However, their specific role in CEAD is poorly investigated. Our aim was to compare the prevalence of vascular risk factors in CEAD patients versus referents and patients who suffered an IS of a cause other than CEAD (non-CEAD IS) in the multicenter Cervical Artery Dissection and Ischemic Stroke Patients (CADISP) study. The study sample comprised 690 CEAD patients (mean age, 44.2 ± 9.9 years; 43.9% women), 556 patients with a non-CEAD IS (44.7 ± 10.5 years; 39.9% women), and 1170 referents (45.9 ± 8.1 years; 44.1% women). We compared the prevalence of hypertension, diabetes mellitus, hypercholesterolemia, smoking, and obesity (body mass index ≥ 30 kg/m²) or overweightness (body mass index ≥ 25 kg/m² and <30 kg/m²) between the 3 groups using a multinomial logistic regression adjusted for country of inclusion, age, and gender. Compared with referents, CEAD patients had a lower prevalence of hypercholesterolemia (odds ratio 0.55; 95% confidence interval, 0.42 to 0.71; P<0.0001), obesity (odds ratio 0.37; 95% confidence interval, 0.26 to 0.52; P<0.0001), and overweightness (odds ratio 0.70; 95% confidence interval, 0.57 to 0.88; P=0.002) but were more frequently hypertensive (odds ratio 1.67; 95% confidence interval, 1.32 to 2.1; P<0.0001). All vascular risk factors were less frequent in CEAD patients compared with young patients with a non-CEAD IS. The latter were more frequently hypertensive, diabetic, and current smokers compared with referents. These results, from the largest series to date, suggest that hypertension, although less prevalent than in patients with a non-CEAD IS, could be a risk factor of CEAD, whereas hypercholesterolemia, obesity, and overweightness are inversely associated with CEAD.

  2. Rapid Contour-based Segmentation for 18F-FDG PET Imaging of Lung Tumors by Using ITK-SNAP: Comparison to Expert-based Segmentation.

    PubMed

    Besson, Florent L; Henry, Théophraste; Meyer, Céline; Chevance, Virgile; Roblot, Victoire; Blanchet, Elise; Arnould, Victor; Grimon, Gilles; Chekroun, Malika; Mabille, Laurence; Parent, Florence; Seferian, Andrei; Bulifon, Sophie; Montani, David; Humbert, Marc; Chaumet-Riffaud, Philippe; Lebon, Vincent; Durand, Emmanuel

    2018-04-03

    Purpose To assess the performance of the ITK-SNAP software for fluorodeoxyglucose (FDG) positron emission tomography (PET) segmentation of complex-shaped lung tumors compared with an optimized, expert-based manual reference standard. Materials and Methods Seventy-six FDG PET images of thoracic lesions were retrospectively segmented by using ITK-SNAP software. Each tumor was manually segmented by six raters to generate an optimized reference standard by using the simultaneous truth and performance level estimate algorithm. Four raters segmented 76 FDG PET images of lung tumors twice by using ITK-SNAP active contour algorithm. Accuracy of ITK-SNAP procedure was assessed by using Dice coefficient and Hausdorff metric. Interrater and intrarater reliability were estimated by using intraclass correlation coefficients of output volumes. Finally, the ITK-SNAP procedure was compared with currently recommended PET tumor delineation methods on the basis of thresholding at 41% volume of interest (VOI; VOI 41 ) and 50% VOI (VOI 50 ) of the tumor's maximal metabolism intensity. Results Accuracy estimates for the ITK-SNAP procedure indicated a Dice coefficient of 0.83 (95% confidence interval: 0.77, 0.89) and a Hausdorff distance of 12.6 mm (95% confidence interval: 9.82, 15.32). Interrater reliability was an intraclass correlation coefficient of 0.94 (95% confidence interval: 0.91, 0.96). The intrarater reliabilities were intraclass correlation coefficients above 0.97. Finally, VOI 41 and VOI 50 accuracy metrics were as follows: Dice coefficient, 0.48 (95% confidence interval: 0.44, 0.51) and 0.34 (95% confidence interval: 0.30, 0.38), respectively, and Hausdorff distance, 25.6 mm (95% confidence interval: 21.7, 31.4) and 31.3 mm (95% confidence interval: 26.8, 38.4), respectively. Conclusion ITK-SNAP is accurate and reliable for active-contour-based segmentation of heterogeneous thoracic PET tumors. ITK-SNAP surpassed the recommended PET methods compared with ground truth manual segmentation. © RSNA, 2018.

  3. Quantitative imaging biomarkers: Effect of sample size and bias on confidence interval coverage.

    PubMed

    Obuchowski, Nancy A; Bullen, Jennifer

    2017-01-01

    Introduction Quantitative imaging biomarkers (QIBs) are being increasingly used in medical practice and clinical trials. An essential first step in the adoption of a quantitative imaging biomarker is the characterization of its technical performance, i.e. precision and bias, through one or more performance studies. Then, given the technical performance, a confidence interval for a new patient's true biomarker value can be constructed. Estimating bias and precision can be problematic because rarely are both estimated in the same study, precision studies are usually quite small, and bias cannot be measured when there is no reference standard. Methods A Monte Carlo simulation study was conducted to assess factors affecting nominal coverage of confidence intervals for a new patient's quantitative imaging biomarker measurement and for change in the quantitative imaging biomarker over time. Factors considered include sample size for estimating bias and precision, effect of fixed and non-proportional bias, clustered data, and absence of a reference standard. Results Technical performance studies of a quantitative imaging biomarker should include at least 35 test-retest subjects to estimate precision and 65 cases to estimate bias. Confidence intervals for a new patient's quantitative imaging biomarker measurement constructed under the no-bias assumption provide nominal coverage as long as the fixed bias is <12%. For confidence intervals of the true change over time, linearity must hold and the slope of the regression of the measurements vs. true values should be between 0.95 and 1.05. The regression slope can be assessed adequately as long as fixed multiples of the measurand can be generated. Even small non-proportional bias greatly reduces confidence interval coverage. Multiple lesions in the same subject can be treated as independent when estimating precision. Conclusion Technical performance studies of quantitative imaging biomarkers require moderate sample sizes in order to provide robust estimates of bias and precision for constructing confidence intervals for new patients. Assumptions of linearity and non-proportional bias should be assessed thoroughly.

  4. Immediate and delayed recall of a small-scale spatial array.

    PubMed

    Tlauka, Michael; Donaldson, Phillip; Bonnar, Daniel

    2015-01-01

    The study examined people's spatial memory of a small-scale array of objects. Earlier work has primarily relied on short-retention intervals, and to date it is not known whether performance is affected by longer intervals between learning and recall. In the present investigation, university students studied seven target objects. Recall was tested immediately after learning and after an interval of seven days. Performance was found to be similar in the immediate and delayed conditions, and the results suggested that recall was facilitated by egocentric and intrinsic cues. The findings are discussed with reference to recent investigations that have shown task parameters can influence spatial recall.

  5. A Proposal of New Reference System for the Standard Axial, Sagittal, Coronal Planes of Brain Based on the Serially-Sectioned Images

    PubMed Central

    Park, Jin Seo; Park, Hyo Seok; Shin, Dong Sun; Har, Dong-Hwan; Cho, Zang-Hee; Kim, Young-Bo; Han, Jae-Yong; Chi, Je-Geun

    2010-01-01

    Sectional anatomy of human brain is useful to examine the diseased brain as well as normal brain. However, intracerebral reference points for the axial, sagittal, and coronal planes of brain have not been standardized in anatomical sections or radiological images. We made 2,343 serially-sectioned images of a cadaver head with 0.1 mm intervals, 0.1 mm pixel size, and 48 bit color and obtained axial, sagittal, and coronal images based on the proposed reference system. This reference system consists of one principal reference point and two ancillary reference points. The two ancillary reference points are the anterior commissure and the posterior commissure. And the principal reference point is the midpoint of two ancillary reference points. It resides in the center of whole brain. From the principal reference point, Cartesian coordinate of x, y, z could be made to be the standard axial, sagittal, and coronal planes. PMID:20052359

  6. Acceptability of VTOL aircraft noise determined by absolute subjective testing

    NASA Technical Reports Server (NTRS)

    Sternfeld, H., Jr.; Hinterkeuser, E. G.; Hackman, R. B.; Davis, J.

    1972-01-01

    A program was conducted during which test subjects evaluated the simulated sounds of a helicopter, a tilt wing aircraft, and a 15 second, 90 PNdB (indoors) turbojet aircraft used as reference. Over 20,000 evaluations were made while the test subjects were engaged in work and leisure activities. The effects of level, exposure time, distance and aircraft design on subjective acceptability were evaluated. Some of the important conclusions are: (1) To be judged equal in annoyance to the reference jet sound, the helicopter and tilt wing sounds must be 4 to 5 PNdB lower when lasting 15 seconds in duration. (2) To be judged significantly more acceptable than the reference jet sound, the helicopter sound must be 10 PNdB lower when lasting 15 seconds in duration. (3) To be judged significantly more acceptable than the reference jet sound, the tilt wing sound must be 12 PNdB lower when lasting 15 seconds in duration. (4) The relative effect of changing the duration of a sound upon its subjectively rated annoyance diminishes with increasing duration. It varies from 2 PNdB per doubling of duration for intervals of 15 to 30 seconds, to 0.75 PNdB per doubling of duration for intervals of 120 to 240 seconds.

  7. A modified Wald interval for the area under the ROC curve (AUC) in diagnostic case-control studies

    PubMed Central

    2014-01-01

    Background The area under the receiver operating characteristic (ROC) curve, referred to as the AUC, is an appropriate measure for describing the overall accuracy of a diagnostic test or a biomarker in early phase trials without having to choose a threshold. There are many approaches for estimating the confidence interval for the AUC. However, all are relatively complicated to implement. Furthermore, many approaches perform poorly for large AUC values or small sample sizes. Methods The AUC is actually a probability. So we propose a modified Wald interval for a single proportion, which can be calculated on a pocket calculator. We performed a simulation study to compare this modified Wald interval (without and with continuity correction) with other intervals regarding coverage probability and statistical power. Results The main result is that the proposed modified Wald intervals maintain and exploit the type I error much better than the intervals of Agresti-Coull, Wilson, and Clopper-Pearson. The interval suggested by Bamber, the Mann-Whitney interval without transformation and also the interval of the binormal AUC are very liberal. For small sample sizes the Wald interval with continuity has a comparable coverage probability as the LT interval and higher power. For large sample sizes the results of the LT interval and of the Wald interval without continuity correction are comparable. Conclusions If individual patient data is not available, but only the estimated AUC and the total sample size, the modified Wald intervals can be recommended as confidence intervals for the AUC. For small sample sizes the continuity correction should be used. PMID:24552686

  8. A modified Wald interval for the area under the ROC curve (AUC) in diagnostic case-control studies.

    PubMed

    Kottas, Martina; Kuss, Oliver; Zapf, Antonia

    2014-02-19

    The area under the receiver operating characteristic (ROC) curve, referred to as the AUC, is an appropriate measure for describing the overall accuracy of a diagnostic test or a biomarker in early phase trials without having to choose a threshold. There are many approaches for estimating the confidence interval for the AUC. However, all are relatively complicated to implement. Furthermore, many approaches perform poorly for large AUC values or small sample sizes. The AUC is actually a probability. So we propose a modified Wald interval for a single proportion, which can be calculated on a pocket calculator. We performed a simulation study to compare this modified Wald interval (without and with continuity correction) with other intervals regarding coverage probability and statistical power. The main result is that the proposed modified Wald intervals maintain and exploit the type I error much better than the intervals of Agresti-Coull, Wilson, and Clopper-Pearson. The interval suggested by Bamber, the Mann-Whitney interval without transformation and also the interval of the binormal AUC are very liberal. For small sample sizes the Wald interval with continuity has a comparable coverage probability as the LT interval and higher power. For large sample sizes the results of the LT interval and of the Wald interval without continuity correction are comparable. If individual patient data is not available, but only the estimated AUC and the total sample size, the modified Wald intervals can be recommended as confidence intervals for the AUC. For small sample sizes the continuity correction should be used.

  9. Haematological and biochemical measurements in healthy, adult, free-ranging golden jackals (Canis aureus syriacus) held in captivity.

    PubMed

    Aroch, I; Shpigel, N Y; Avidar, Y; Yakobson, B; King, R; Shamir, M

    2005-09-10

    Blood from 31 healthy, free-ranging golden jackals held in captivity for seven days was collected while they were anaesthetised. Haematological and serum biochemical measurements were analysed and the 95 per cent confidence interval for each variable was compared with the reference value for domestic dogs. The measurements of their red blood cells were within the reference interval for dogs, but the jackals had higher white blood cell counts and eosinophil counts than dogs. The male jackals had a higher haematocrit, red blood cell count, mean corpuscular volume and mean corpuscular haemoglobin concentration, and a lower red blood cell distribution width than the female jackals. High activities of muscle enzymes were detected in many of the jackals, in several of which the activity of creatine kinase exceeded 5000 U/l; these were considered abnormal.

  10. Context-Dependent Duration Signals in the Primate Prefrontal Cortex

    PubMed Central

    Genovesio, Aldo; Seitz, Lucia K.; Tsujimoto, Satoshi; Wise, Steven P.

    2016-01-01

    The activity of some prefrontal (PF) cortex neurons distinguishes short from long time intervals. Here, we examined whether this property reflected a general timing mechanism or one dependent on behavioral context. In one task, monkeys discriminated the relative duration of 2 stimuli; in the other, they discriminated the relative distance of 2 stimuli from a fixed reference point. Both tasks had a pre-cue period (interval 1) and a delay period (interval 2) with no discriminant stimulus. Interval 1 elapsed before the presentation of the first discriminant stimulus, and interval 2 began after that stimulus. Both intervals had durations of either 400 or 800 ms. Most PF neurons distinguished short from long durations in one task or interval, but not in the others. When neurons did signal something about duration for both intervals, they did so in an uncorrelated or weakly correlated manner. These results demonstrate a high degree of context dependency in PF time processing. The PF, therefore, does not appear to signal durations abstractedly, as would be expected of a general temporal encoder, but instead does so in a highly context-dependent manner, both within and between tasks. PMID:26209845

  11. Pediatric reference intervals for alkaline phosphatase.

    PubMed

    Zierk, Jakob; Arzideh, Farhad; Haeckel, Rainer; Cario, Holger; Frühwald, Michael C; Groß, Hans-Jürgen; Gscheidmeier, Thomas; Hoffmann, Reinhard; Krebs, Alexander; Lichtinghagen, Ralf; Neumann, Michael; Ruf, Hans-Georg; Steigerwald, Udo; Streichert, Thomas; Rascher, Wolfgang; Metzler, Markus; Rauh, Manfred

    2017-01-01

    Interpretation of alkaline phosphatase activity in children is challenging due to extensive changes with growth and puberty leading to distinct sex- and age-specific dynamics. Continuous percentile charts from birth to adulthood allow accurate consideration of these dynamics and seem reasonable for an analyte as closely linked to growth as alkaline phosphatase. However, the ethical and practical challenges unique to pediatric reference intervals have restricted the creation of such percentile charts, resulting in limitations when clinical decisions are based on alkaline phosphatase activity. We applied an indirect method to generate percentile charts for alkaline phosphatase activity using clinical laboratory data collected during the clinical care of patients. A total of 361,405 samples from 124,440 patients from six German tertiary care centers and one German laboratory service provider measured between January 2004 and June 2015 were analyzed. Measurement of alkaline phosphatase activity was performed on Roche Cobas analyzers using the IFCC's photometric method. We created percentile charts for alkaline phosphatase activity in girls and boys from birth to 18 years which can be used as reference intervals. Additionally, data tables of age- and sex-specific percentile values allow the incorporation of these results into laboratory information systems. The percentile charts provided enable the appropriate differential diagnosis of changes in alkaline phosphatase activity due to disease and changes due to physiological development. After local validation, integration of the provided percentile charts into result reporting facilitates precise assessment of alkaline phosphatase dynamics in pediatrics.

  12. Serum Biochemical Phenotypes in the Domestic Dog

    PubMed Central

    Chang, Yu-Mei; Hadox, Erin; Szladovits, Balazs; Garden, Oliver A.

    2016-01-01

    The serum or plasma biochemical profile is essential in the diagnosis and monitoring of systemic disease in veterinary medicine, but current reference intervals typically take no account of breed-specific differences. Breed-specific hematological phenotypes have been documented in the domestic dog, but little has been published on serum biochemical phenotypes in this species. Serum biochemical profiles of dogs in which all measurements fell within the existing reference intervals were retrieved from a large veterinary database. Serum biochemical profiles from 3045 dogs were retrieved, of which 1495 had an accompanying normal glucose concentration. Sixty pure breeds plus a mixed breed control group were represented by at least 10 individuals. All analytes, except for sodium, chloride and glucose, showed variation with age. Total protein, globulin, potassium, chloride, creatinine, cholesterol, total bilirubin, ALT, CK, amylase, and lipase varied between sexes. Neutering status significantly impacted all analytes except albumin, sodium, calcium, urea, and glucose. Principal component analysis of serum biochemical data revealed 36 pure breeds with distinctive phenotypes. Furthermore, comparative analysis identified 23 breeds with significant differences from the mixed breed group in all biochemical analytes except urea and glucose. Eighteen breeds were identified by both principal component and comparative analysis. Tentative reference intervals were generated for breeds with a distinctive phenotype identified by comparative analysis and represented by at least 120 individuals. This is the first large-scale analysis of breed-specific serum biochemical phenotypes in the domestic dog and highlights potential genetic components of biochemical traits in this species. PMID:26919479

  13. Characterization and Uncertainty Analysis of a Reference Pressure Measurement System for Wind Tunnels

    NASA Technical Reports Server (NTRS)

    Amer, Tahani; Tripp, John; Tcheng, Ping; Burkett, Cecil; Sealey, Bradley

    2004-01-01

    This paper presents the calibration results and uncertainty analysis of a high-precision reference pressure measurement system currently used in wind tunnels at the NASA Langley Research Center (LaRC). Sensors, calibration standards, and measurement instruments are subject to errors due to aging, drift with time, environment effects, transportation, the mathematical model, the calibration experimental design, and other factors. Errors occur at every link in the chain of measurements and data reduction from the sensor to the final computed results. At each link of the chain, bias and precision uncertainties must be separately estimated for facility use, and are combined to produce overall calibration and prediction confidence intervals for the instrument, typically at a 95% confidence level. The uncertainty analysis and calibration experimental designs used herein, based on techniques developed at LaRC, employ replicated experimental designs for efficiency, separate estimation of bias and precision uncertainties, and detection of significant parameter drift with time. Final results, including calibration confidence intervals and prediction intervals given as functions of the applied inputs, not as a fixed percentage of the full-scale value are presented. System uncertainties are propagated beginning with the initial reference pressure standard, to the calibrated instrument as a working standard in the facility. Among the several parameters that can affect the overall results are operating temperature, atmospheric pressure, humidity, and facility vibration. Effects of factors such as initial zeroing and temperature are investigated. The effects of the identified parameters on system performance and accuracy are discussed.

  14. A bioequivalence study of two memantine formulations in healthy Chinese male volunteers
.

    PubMed

    Deng, Ying; Zhuang, Jialang; Wu, Jingguo; Chen, Jiangying; Ding, Liang; Wang, Xueding; Huang, Lihui; Zeng, Guixiong; Chen, Jie; Ma, Zhongfu; Chen, Xiao; Zhong, Guoping; Huang, Min; Zhao, Xianglan

    2017-10-01

    The aim of the current study is to evaluate the bioequivalence between the test and reference formulations of memantine in a single-dose, two-period and two-sequence crossover study with a 44-day washout interval. A total of 20 healthy Chinese male volunteers were enrolled and completed the study, after oral administration of single doses of 10 mg test and reference formulations of memantine. The blood samples were collected at different time points and memantine concentrations were determined by a fully validated HPLC-MS/MS method. The evaluated pharmacokinetic parameters (test vs. reference) including Cmax (18 ± 3.2 vs. 17.8 ± 3.4), AUC0-t (1,188.5 ± 222.2 vs. 1,170.9 ± 135.7), and AUC0-∞ (1,353.3 ± 258.6 vs. 1,291.3 ± 136.7) values were assessed for bioequivalence based on current guidelines. The observed pharmacokinetic parameters of memantine test drug were similar to those of the reference formulation. The 90% confidence intervals of test/reference ratios for Cmax, AUC0-t, and AUC0-∞ were within the bioequivalence acceptance range of 80 - 125%. The results obtained from the healthy Chinese subjects in this study suggests that the test formulation of memantine 10 mg tablet is bioequivalent to the reference formulation (Ebixa®10 mg tablet).
.

  15. Lake Louise Water (USGS47): A new isotopic reference water for stable hydrogen and oxygen isotope measurements

    USGS Publications Warehouse

    Qi, Haiping; Lorenz, Jennifer M.; Coplen, Tyler B.; Tarbox, Lauren V.; Mayer, Bernhard; Taylor, Steve

    2014-01-01

    RESULTS: The δ2H and δ18O values of this reference water are –150.2 ± 0.5 ‰ and –19.80 ± 0.02 ‰, respectively, relative to VSMOW on scales normalized such that the δ2H and δ18O values of SLAP reference water are, respectively, –428 and –55.5 ‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95-percent probability of encompassing the true value. CONCLUSION: This isotopic reference material, designated as USGS47, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and stable oxygen isotopic analysis of water with a mass spectrometer or a laser absorption spectrometer. "

  16. Determination of tungsten in geochemical reference material basalt Columbia River 2 by radiochemical neutron activation analysis and inductively coupled plasma mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morrison, Samuel S.; Beck, Chelsie L.; Bowen, James M.

    Environmental tungsten (W) analyses are inhibited by a lack of reference materials and practical methods to remove isobaric and radiometric interferences. We present a method that evaluates the potential use of commercially available sediment, Basalt Columbia River-2 (BCR-2), as a reference material using neutron activation analysis (NAA) and mass spectrometry. Tungsten concentrations using both methods are in statistical agreement at the 95% confidence interval (92 ± 4 ng/g for NAA and 100 ±7 ng/g for mass spectrometry) with recoveries greater than 95%. These results indicate that BCR-2 may be suitable as a reference material for future studies.

  17. Pattern and Predictors of Outpatient Palliative Care Referral Among Thoracic Medical Oncologists.

    PubMed

    Hui, David; Kilgore, Kelly; Park, Minjeong; Liu, Diane; Kim, Yu Jung; Park, Ji Chan; Fossella, Frank; Bruera, Eduardo

    2018-06-12

    There is significant variation in access to palliative care. We examined the pattern of outpatient palliative care referral among thoracic medical oncologists and identified oncologist characteristics associated with greater referral. We retrieved data on all patients who died of advanced thoracic malignancies at our institution between January 1, 2007, and December 31, 2012. Using median as a cutoff, we defined two groups (high-referring and low-referring oncologists) based on their frequency of referral. We examined various oncologist- and patient-related characteristics associated with outpatient referral. Of 1,642 decedents, 444 (27%) had an outpatient palliative care referral. The median proportion of referral among 26 thoracic oncologists was 30% (range 9%-45%; median proportion of high-referring 37% vs. low-referring 24% when divided into two groups at median). High-referring oncologists were significantly younger (age 45 vs. 56) than low-referring oncologists; they were also significantly more likely to refer patients earlier (median interval between oncology consultation and palliative care consultation 90 days vs. 170 days) and to refer those without metastatic disease (7% vs. 2%). In multivariable mixed-effect logistic regression, younger oncologists (odds ratio [OR] = 0.97 per year increase, 95% confidence interval [CI] 0.95-0.995), younger patients (OR = 0.98 per year increase, 95% CI 0.97-0.99), and nonmetastatic disease status (OR = 0.48, 95% CI 0.29-0.78) were significantly associated with outpatient palliative care referral. The pattern of referral to outpatient palliative care varied widely among thoracic oncologists. Younger oncologists were not only referring a higher proportion of patients, but also referring patients earlier in the disease trajectory. This retrospective cohort study found that younger thoracic medical oncologists were significantly more likely to refer patients to outpatient palliative care and to do so earlier in the disease trajectory compared with older oncologists, even after adjusting for other known predictors such as patient demographics. The findings highlight the role of education to standardize palliative care access and imply that outpatient palliative care referral is likely to continue to increase with a shifting oncology workforce. © AlphaMed Press 2018.

  18. Bioequivalence and Pharmacokinetic Evaluation Study of Acetaminophen vs. Acetaminophen Plus Caffeine Tablets in Healthy Mexican Volunteers.

    PubMed

    Guzmán, Nora Angélica Núñez; Molina, Daniel Ruiz; Núñez, Benigno Figueroa; Soto-Sosa, Juan Carlos; Abarca, Jorge Eduardo Herrera

    2016-12-01

    The aim of this clinical trial was to establish the bioequivalence of two tablets containing acetaminophen 650 mg (reference) and acetaminophen 650 mg plus caffeine 65 mg (test), administered orally, in fasting conditions in healthy Mexican volunteers. Blood samples were taken from 21 male and five female individuals, during a 24-h period, to characterize the pharmacokinetic profile of acetaminophen. Plasma samples were quantified by ultra-performance liquid chromatography, tandem mass spectrometry. Pharmacokinetic metrics (maximum plasma concentration, area under the curve from time zero to the last sampling time, and area under the curve from time zero to infinity) were used to determine the 90 % confidence interval of the test/reference coefficient. The geometric mean values for maximum plasma concentration obtained for the reference and test products were 9.46 ± 34.21 and 9.72 ± 32.38 µg/mL, respectively, whereas for the area under the curve from time zero to the last sampling time the values obtained were 34.93 ± 32.58 and 35.89 ± 31.03 µg h/mL for the reference and test formulations, respectively. The 90 % confidence intervals were within the acceptance range (80-125 %). The test product was bioequivalent to the reference product. A faster absorption was seen in the test formulation in the Mexican population.

  19. 49 CFR 195.432 - Inspection of in-service breakout tanks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... low-pressure steel aboveground breakout tanks according to API Standard 653 (incorporated by reference... breakout tanks built to API Standard 2510 according to section 6 of API 510. (d) The intervals of...

  20. 49 CFR 195.432 - Inspection of in-service breakout tanks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... low-pressure steel aboveground breakout tanks according to API Standard 653 (incorporated by reference... breakout tanks built to API Standard 2510 according to section 6 of API 510. (d) The intervals of...

  1. 49 CFR 195.432 - Inspection of in-service breakout tanks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... low-pressure steel aboveground breakout tanks according to API Standard 653 (incorporated by reference... breakout tanks built to API Standard 2510 according to section 6 of API 510. (d) The intervals of...

  2. 49 CFR 195.432 - Inspection of in-service breakout tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... low-pressure steel aboveground breakout tanks according to API Standard 653 (incorporated by reference... breakout tanks built to API Standard 2510 according to section 6 of API 510. (d) The intervals of...

  3. 49 CFR 195.432 - Inspection of in-service breakout tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... low-pressure steel aboveground breakout tanks according to API Standard 653 (incorporated by reference... breakout tanks built to API Standard 2510 according to section 6 of API 510. (d) The intervals of...

  4. [Pediatric reference intervals : retrospective study on thyroid hormone levels].

    PubMed

    Ladang, A; Vranken, L; Luyckx, F; Lebrethon, M-C; Cavalier, E

    2017-01-01

    Defining reference range is an essential tool for diagnostic. Age and sexe influences on thyroid hormone levels have been already discussed. In this study, we are defining a new pediatric reference range for TSH, FT3 and FT4 for Cobas C6000 analyzer. To do so, we have taken in account 0 to 18 year old outclinic patients. During the first year of life, thyroid hormone levels change dramatically before getting stabilized around 3 years old. We also compared our results to those obtained in a Canadian large-scale prospective study (the CALIPER initiative).

  5. Using Solar Radio Burst Integrated Fluxes to Predict Energetic Proton Flux Increases.

    DTIC Science & Technology

    1982-08-31

    Energy Density, ET, of the radio burst, an integration across the frequency interval of the time-integrated radio fluxes at each frequency, was found to...integrated flux or energy at five frequencies in the 600- to 8800-MHz frequency interval and related them to the peak proton flux of the associated... energy of the burst normalized to its peak flux. One other characteristic of the radio burst to which Croom 13 referred was the total energy density, ET

  6. Multiple-Frequency Ultrasonic Pulse-Echo Display System.

    DTIC Science & Technology

    1982-09-28

    will sweep across some time interval. Adjust the ramp rate potentiometer to set this interval to exactly 10 ps. Ramp Delay None Set time base to 1.0 lis...the function keys. The table is a printout which results F.irectly from exercising Program KEE, listed in Appendix C-I. Note that "(ESC)B" refers to...flag +21 ŕ" = one-time flag (nessage is presented prior to full plot once per session) +22 time- base duration code +23 (High order digit) +24 * +25

  7. Pharmacokinetics and bioequivalence study of two brands of loxoprofen tablets in healthy volunteers.

    PubMed

    Jhee, Ok Hwa; Lee, Min Ho; Shaw, Leslie M; Lee, Seo Eun; Park, Jin Hee; Kang, Ju Seop

    2007-01-01

    The aims of this study were to assess the pharmacokinetics and bioequivalence of two brands of loxoprofen (CAS 80832-23-6) 60 mg tablets in healthy male volunteers. The several pharmacokinetic parameters were evaluated after an oral administration after an overnight fast according to a single dose, two-sequence, and cross-over randomized design with a 1-week washout interval. Serial blood samples were collected throughout 10 h after administration of the reference and test drug. Plasma was analyzed by validated HPLC with UV detection. Several pharmacokinetic parameters, including AUC(infnity), AUC(t), C(max), T(max), T1/2, and Ke were determined from blood concentrations of both formulations. AUC(t), AUC(infinity) and C(max) were evaluated for bioequivalence after log-transformation of data using ANOVA with 90% confidence interval level. The parametric 90% confidence intervals of AUC(t), AUC(infinity), and C(max) were 90.13-106.34%, 91.43-106.94%, and 91.17-108.53%, respectively. All of the tested parameters were within the acceptable range of 80-125%. Based on these statistical considerations, it was concluded that the test drug was bioequivalent to the reference drug.

  8. Age effects on discrimination of timing in auditory sequences

    NASA Astrophysics Data System (ADS)

    Fitzgibbons, Peter J.; Gordon-Salant, Sandra

    2004-08-01

    The experiments examined age-related changes in temporal sensitivity to increments in the interonset intervals (IOI) of components in tonal sequences. Discrimination was examined using reference sequences consisting of five 50-ms tones separated by silent intervals; tone frequencies were either fixed at 4 kHz or varied within a 2-4-kHz range to produce spectrally complex patterns. The tonal IOIs within the reference sequences were either equal (200 or 600 ms) or varied individually with an average value of 200 or 600 ms to produce temporally complex patterns. The difference limen (DL) for increments of IOI was measured. Comparison sequences featured either equal increments in all tonal IOIs or increments in a single target IOI, with the sequential location of the target changing randomly across trials. Four groups of younger and older adults with and without sensorineural hearing loss participated. Results indicated that DLs for uniform changes of sequence rate were smaller than DLs for single target intervals, with the largest DLs observed for single targets embedded within temporally complex sequences. Older listeners performed more poorly than younger listeners in all conditions, but the largest age-related differences were observed for temporally complex stimulus conditions. No systematic effects of hearing loss were observed.

  9. Publications - GMC 110 | Alaska Division of Geological & Geophysical

    Science.gov Websites

    foot interval of the Richfield Oil Corporation White River Unit #2 well Authors: Bujak Davies Group Reference Bujak Davies Group, 1989, Vitrinite reflectance data and analysis of the 120 - 12,100 foot

  10. Publications - GMC 108 | Alaska Division of Geological & Geophysical

    Science.gov Websites

    foot interval of the Consolidated Oil Iniskin Unit Zappa #1 well Authors: Bujak Davies Group Reference Bujak Davies Group, 1989, Vitrinite reflectance data and analysis of the 1,000 - 11,230 foot

  11. Publications - GMC 109 | Alaska Division of Geological & Geophysical

    Science.gov Websites

    foot interval of the Colorado Oil Malaspina Unit #1-A well Authors: Bujak Davies Group Publication Date Reference Bujak Davies Group, 1989, Vitrinite reflectance data and analysis of the 900 - 13,816 foot

  12. Breast Cancer Risk Assessment SAS Macro (Gail Model)

    Cancer.gov

    A SAS macro (commonly referred to as the Gail Model) that projects absolute risk of invasive breast cancer according to NCI’s Breast Cancer Risk Assessment Tool (BCRAT) algorithm for specified race/ethnic groups and age intervals.

  13. The influence of action-outcome delay and arousal on sense of agency and the intentional binding effect.

    PubMed

    Wen, Wen; Yamashita, Atsushi; Asama, Hajime

    2015-11-01

    The sense of agency refers to the feeling of being able to initiate and control events through one's actions. The "intentional binding" effect (Haggard, Clark, & Kalogeras, 2002), refers to a subjective compression of the temporal interval between actions and their effects. The present study examined the influence of action-outcome delays and arousal on both the subjective judgment of agency and the intentional binding effect. In the experiment, participants pressed a key to trigger a central square to jump after various delays. A red central square was used in the high-arousal condition. Results showed that a longer interval between actions and their effects was associated with a lower sense of agency but a stronger intentional binding effect. Furthermore, although arousal enhanced the intentional binding effect, it did not influence the judgment of agency. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. The Wavelet Element Method. Part 2; Realization and Additional Features in 2D and 3D

    NASA Technical Reports Server (NTRS)

    Canuto, Claudio; Tabacco, Anita; Urban, Karsten

    1998-01-01

    The Wavelet Element Method (WEM) provides a construction of multiresolution systems and biorthogonal wavelets on fairly general domains. These are split into subdomains that are mapped to a single reference hypercube. Tensor products of scaling functions and wavelets defined on the unit interval are used on the reference domain. By introducing appropriate matching conditions across the interelement boundaries, a globally continuous biorthogonal wavelet basis on the general domain is obtained. This construction does not uniquely define the basis functions but rather leaves some freedom for fulfilling additional features. In this paper we detail the general construction principle of the WEM to the 1D, 2D and 3D cases. We address additional features such as symmetry, vanishing moments and minimal support of the wavelet functions in each particular dimension. The construction is illustrated by using biorthogonal spline wavelets on the interval.

  15. Real Time Correction of Aircraft Flight Fonfiguration

    NASA Technical Reports Server (NTRS)

    Schipper, John F. (Inventor)

    2009-01-01

    Method and system for monitoring and analyzing, in real time, variation with time of an aircraft flight parameter. A time-dependent recovery band, defined by first and second recovery band boundaries that are spaced apart at at least one time point, is constructed for a selected flight parameter and for a selected time recovery time interval length .DELTA.t(FP;rec). A flight parameter, having a value FP(t=t.sub.p) at a time t=t.sub.p, is likely to be able to recover to a reference flight parameter value FP(t';ref), lying in a band of reference flight parameter values FP(t';ref;CB), within a time interval given by t.sub.p.ltoreq.t'.ltoreq.t.sub.p.DELTA.t(FP;rec), if (or only if) the flight parameter value lies between the first and second recovery band boundary traces.

  16. Identifying Significant Changes in Cerebrovascular Reactivity to Carbon Dioxide.

    PubMed

    Sobczyk, O; Crawley, A P; Poublanc, J; Sam, K; Mandell, D M; Mikulis, D J; Duffin, J; Fisher, J A

    2016-05-01

    Changes in cerebrovascular reactivity can be used to assess disease progression and response to therapy but require discrimination of pathology from normal test-to-test variability. Such variability is due to variations in methodology, technology, and physiology with time. With uniform test conditions, our aim was to determine the test-to-test variability of cerebrovascular reactivity in healthy subjects and in patients with known cerebrovascular disease. Cerebrovascular reactivity was the ratio of the blood oxygen level-dependent MR imaging response divided by the change in carbon dioxide stimulus. Two standardized cerebrovascular reactivity tests were conducted at 3T in 15 healthy men (36.7 ± 16.1 years of age) within a 4-month period and were coregistered into standard space to yield voxelwise mean cerebrovascular reactivity interval difference measures, composing a reference interval difference atlas. Cerebrovascular reactivity interval difference maps were prepared for 11 male patients. For each patient, the test-retest difference of each voxel was scored statistically as z-values of the corresponding voxel mean difference in the reference atlas and then color-coded and superimposed on the anatomic images to create cerebrovascular reactivity interval difference z-maps. There were no significant test-to-test differences in cerebrovascular reactivity in either gray or white matter (mean gray matter, P = .431; mean white matter, P = .857; paired t test) in the healthy cohort. The patient cerebrovascular reactivity interval difference z-maps indicated regions where cerebrovascular reactivity increased or decreased and the probability that the changes were significant. Accounting for normal test-to-test differences in cerebrovascular reactivity enables the assessment of significant changes in disease status (stability, progression, or regression) in patients with time. © 2016 by American Journal of Neuroradiology.

  17. Regional curve development and selection of a reference reach in the non-urban, lowland sections of the Piedmont physiographic province, Pennsylvania and Maryland

    USGS Publications Warehouse

    White, Kirk E.

    2001-01-01

    Stream-restoration projects utilizing naturalstream designs frequently are based on the bankfull- channel characteristics of a stream reach that is accommodating streamflow and sediment transport without excessive erosion or deposition. The bankfull channel is identified by the use of field indicators and confirmed with tools such as regional curves. Channel dimensions were surveyed at six streamflow-measurement stations operated by the U.S. Geological Survey in the Gettysburg-Newark Lowlands Section and Piedmont Lowlands Section of the Piedmont Physiographic Province in Pennsylvania and Maryland. Regional curves were developed from regression analyses of the relation between drainage area and cross-sectional area, mean depth, width, and streamflow of the bankfull channel. Regional curves were used to confirm the identification of the bankfull channel at a reference reach. Stream dimensions and characteristics of the reference reach were measured for extrapolation into the design of a steam-restoration project on Bermudian Creek in Adams County, Pa.Dimensions for cross-sectional area, mean depth, width, and computed streamflow of the bankfull channel in all surveyed riffle cross sections in the reference reach were within the 95-percent confidence interval bounding the regression line representing bankfull channel geometry in the Lowland Sections of the Piedmont Physiographic Province. The average bankfull cross-sectional area, bankfull mean depth, and computed bankfull discharge for riffle cross sections in the reference reach ranged from 15.4 to 16.5 percent less than estimates determined from the lowland regional curves. Average bankfull channel width was about 2 percent greater than estimates. Cross-sectional area, mean depth, and computed streamflow corresponding to the bankfull stage at the reference reach were 31.4, 44.4, and 9.6 percent less, respectively, than estimates derived from the regional curves developed by Dunne and Leopold in 1978. Average bankfull channel width at the reference reach was 16.7 percent greater than the Dunne and Leopold estimate.The concepts of regional curves and reference reaches can be valuable tools to support efforts in stream restoration. Practitioners of stream restoration need to recognize them as such and realize their limitations. The small number of stations available for analysis is a major limiting factor in the strength of the results of this investigation. Subjective selection criteria may have unnecessarily eliminated streamflow-measurement stations that could have been included in the regional curves. A bankfull discharge with a recurrence interval within the 1- to 2-year range was used as a criteria for confirmation of the bankfull stage at each streamflow-measurement station. Many researchers accept this range for recurrence interval of the bankfull discharge; however, literature provides contradictory evidence. The use of channel-characteristics data from a reference reach without any monitoring data to document the stability of the reference reach over time is a topic of debate.

  18. Diagnostic reference range of κ/λ free light chain ratio to screen for Bence Jones proteinuria is not significantly influenced by GFR.

    PubMed

    Schmidt-Hieltjes, Yvonne; Elshof, Clemens; Roovers, Lian; Ruinemans-Koerts, Janneke

    2016-05-01

    The aim of our study was to analyse whether the κ/λ free light chain ratio reference range for screening for Bence Jones proteinuria should be dependent on the estimated glomerular filtration rate (eGFR). The serum κ/λ free light chain ratio, eGFR, serum M-protein and Bence Jones protein were measured in 544 patients for whom Bence Jones protein analysis was ordered. In the population of patients without Bence Jones proteinuria or a M-protein (n = 402), there is no gradual increase in κ/λ free light chain ratio with diminishing eGFR. The κ/λ free light chain ratio in this group was 0.56-1.86 (95% interval). With this diagnostic reference range of the κ/λ ratio, 105 of the 110 patients with Bence Jones protein could be identified correctly. Only five patients with Bence Jones proteinuria (<0.17 g/L) were missed, without diagnostic or therapeutic consequences. In 36 patients (6.6%), an abnormal κ/λ free light chain ratio was measured without the presence of Bence Jones proteinuria. A κ/λ free light chain ratio in serum can be used safely and efficiently to select urine samples which should be analysed for Bence Jones proteinuria with an electrophoresis/immunofixation technique. Using this diagnostic reference range, the number of urine samples which should be analysed by electrophoresis/immunofixation could be reduced by 74%. The diagnostic reference interval can be determined best in a group of patients for whom Bence Jones analysis is indicated. For calculation of this reference range, the eGFR value does not need to be taken into account. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Applications of asymptotic confidence intervals with continuity corrections for asymmetric comparisons in noninferiority trials.

    PubMed

    Soulakova, Julia N; Bright, Brianna C

    2013-01-01

    A large-sample problem of illustrating noninferiority of an experimental treatment over a referent treatment for binary outcomes is considered. The methods of illustrating noninferiority involve constructing the lower two-sided confidence bound for the difference between binomial proportions corresponding to the experimental and referent treatments and comparing it with the negative value of the noninferiority margin. The three considered methods, Anbar, Falk-Koch, and Reduced Falk-Koch, handle the comparison in an asymmetric way, that is, only the referent proportion out of the two, experimental and referent, is directly involved in the expression for the variance of the difference between two sample proportions. Five continuity corrections (including zero) are considered with respect to each approach. The key properties of the corresponding methods are evaluated via simulations. First, the uncorrected two-sided confidence intervals can, potentially, have smaller coverage probability than the nominal level even for moderately large sample sizes, for example, 150 per group. Next, the 15 testing methods are discussed in terms of their Type I error rate and power. In the settings with a relatively small referent proportion (about 0.4 or smaller), the Anbar approach with Yates' continuity correction is recommended for balanced designs and the Falk-Koch method with Yates' correction is recommended for unbalanced designs. For relatively moderate (about 0.6) and large (about 0.8 or greater) referent proportion, the uncorrected Reduced Falk-Koch method is recommended, although in this case, all methods tend to be over-conservative. These results are expected to be used in the design stage of a noninferiority study when asymmetric comparisons are envisioned. Copyright © 2013 John Wiley & Sons, Ltd.

  20. Thyroid Stimulating Hormone Reference Range and Prevalence of Thyroid Dysfunction in the Korean Population: Korea National Health and Nutrition Examination Survey 2013 to 2015

    PubMed Central

    2017-01-01

    Background No nationwide epidemiological study evaluating the prevalence of subclinical and overt forms of hypothyroidism and hyperthyroidism has yet been conducted in Korea. This study aimed to evaluate the reference range of serum thyroid stimulating hormone (TSH) and the national prevalence of thyroid dysfunctions in Korea. Methods Nation-wide cross-sectional data were analyzed from a representative sample of the civilian, non-institutionalized Korean population (n=6,564) who underwent blood testing for thyroid function and anti-thyroid peroxidase antibody (TPOAb) as part of the Korea National Health and Nutrition Examination Survey VI (2013 to 2015). Results The reference interval of serum TSH in the Korean reference population was 0.62 to 6.68 mIU/L. Based on this reference interval, the prevalence of overt and subclinical hypothyroidism was 0.73% (males 0.40%, females 1.10%) and 3.10% (males 2.26%, females 4.04%), respectively. The prevalence of hypothyroidism increased with age until the age group between 50 to 59 years. Positive TPOAb were found in 7.30% of subjects (males 4.33%, females 10.62%). The prevalence of overt and subclinical hypothyroidism TPOAb-positive subjects was 5.16% and 10.88%, respectively. The prevalence of overt and subclinical hyperthyroidism was 0.54% (males 0.30%, females 0.81%) and 2.98% (males 2.43%, females, 3.59%), respectively. Conclusion The Serum TSH reference levels in the Korean population were higher than the corresponding levels in Western countries. Differences were found in the prevalence of hypothyroidism and hyperthyroidism according to age, sex, and TPOAb positivity. This study provides important baseline information for understanding patterns of thyroid dysfunction and diseases in Korea. PMID:28116874

  1. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): reference data for the trunk and application in patients with chronic postherpetic neuralgia.

    PubMed

    Pfau, Doreen B; Krumova, Elena K; Treede, Rolf-Detlef; Baron, Ralf; Toelle, Thomas; Birklein, Frank; Eich, Wolfgang; Geber, Christian; Gerhardt, Andreas; Weiss, Thomas; Magerl, Walter; Maier, Christoph

    2014-05-01

    Age- and gender-matched reference values are essential for the clinical use of quantitative sensory testing (QST). To extend the standard test sites for QST-according to the German Research Network on Neuropathic Pain-to the trunk, we collected QST profiles on the back in 162 healthy subjects. Sensory profiles for standard test sites were within normal interlaboratory differences. QST revealed lower sensitivity on the upper back than the hand, and higher sensitivity on the lower back than the foot, but no systematic differences between these trunk sites. Age effects were significant for most parameters. Females exhibited lower pressure pain thresholds (PPT) than males, which was the only significant gender difference. Values outside the 95% confidence interval of healthy subjects (considered abnormal) required temperature changes of >3.3-8.2 °C for thermal detection. For cold pain thresholds, confidence intervals extended mostly beyond safety cutoffs, hence only relative reference data (left-right differences, hand-trunk differences) were sufficiently sensitive. For mechanical detection and pain thresholds, left-right differences were 1.5-2.3 times more sensitive than absolute reference data. The most sensitive parameter was PPT, where already side-to-side differences >35% were abnormal. Compared to trunk reference data, patients with postherpetic neuralgia exhibited thermal and tactile deficits and dynamic mechanical allodynia, mostly without reduced mechanical pain thresholds. This pattern deviates from other types of neuropathic pain. QST reference data for the trunk will also be useful for patients with postthoracotomy pain or chronic back pain. Copyright © 2014 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  2. Integrating palliative care across settings: A retrospective cohort study of a hospice home care programme for cancer patients.

    PubMed

    Tan, Woan Shin; Lee, Angel; Yang, Sze Yee; Chan, Susan; Wu, Huei Yaw; Ng, Charis Wei Ling; Heng, Bee Hoon

    2016-07-01

    Terminally ill patients at the end-of-life do transit between care settings due to their complex care needs. Problems of care fragmentation could result in poor quality of care. We aimed to evaluate the impact of an integrated hospice home care programme on acute care service usage and on the share of home deaths. The retrospective study cohort comprised patients who were diagnosed with cancer, had an expected prognosis of 1 year or less, and were referred to a home hospice. The intervention group comprised deceased patients enrolled in the integrated hospice home care programme between September 2012 and June 2014. The historical comparison group comprised deceased patients who were referred to other home hospices between January 2007 and January 2011. There were 321 cases and 593 comparator subjects. Relative to the comparator group, the share of hospital deaths was significantly lower for programme participants (12.1% versus 42.7%). After adjusting for differences at baseline, the intervention group had statistically significantly lower emergency department visits at 30 days (incidence rate ratio: 0.38; 95% confidence interval: 0.31-0.47), 60 days (incidence rate ratio: 0.61; 95% confidence interval: 0.54-0.69) and 90 days (incidence rate ratio: 0.69; 95% confidence interval: 0.62-0.77) prior to death. Similar results held for the number of hospitalisations at 30 days (incidence rate ratio: 0.48; 95% confidence interval: 0.40-0.58), 60 days (incidence rate ratio: 0.71; 95% confidence interval: 0.62-0.82) and 90 days (incidence rate ratio: 0.77; 95% confidence interval: 0.68-0.88) prior to death. Our results demonstrated that by integrating services between acute care and home hospice care, a reduction in acute care service usage could occur. © The Author(s) 2016.

  3. Central retinal artery occlusion - rethinking retinal survival time.

    PubMed

    Tobalem, Stephan; Schutz, James S; Chronopoulos, Argyrios

    2018-04-18

    The critical time from onset of complete occlusion of the central retinal artery (CRA) to functionally significant inner retinal infarction represents a window of opportunity for treatment and also has medical-legal implications, particularly when central retinal artery occlusion (CRAO) complicates therapeutic interventions. Here, we review the evidence for time to infarction from complete CRAO and discuss the implications of our findings. A Medline search was performed using each of the terms "central retinal artery occlusion", "retinal infarction", "retinal ischemia", and "cherry red spot" from 1970 to the present including articles in French and German. All retrieved references as well as their reference lists were screened for relevance. An Internet search using these terms was also performed to look for additional references. We find that the experimental evidence showing that inner retinal infarction occurs after 90-240 min of total CRAO, which is the interval generally accepted in the medical literature and practice guidelines, is flawed in important ways. Moreover, the retinal ganglion cells, supplied by the CRA, are part of the central nervous system which undergoes infarction after non-perfusion of 12-15 min or less. Retinal infarction is most likely to occur after only 12-15 min of complete CRAO. This helps to explain why therapeutic maneuvers for CRAO are often ineffective. Nevertheless, many CRAOs are incomplete and may benefit from therapy after longer intervals. To try to avoid retinal infarcton from inadvertent ocular compression by a headrest during prone anesthesia, the eyes should be checked at intervals of less than 15'.

  4. Laboratory blood analysis in Strigiformes-Part I: hematologic reference intervals and agreement between manual blood cell counting techniques.

    PubMed

    Ammersbach, Mélanie; Beaufrère, Hugues; Gionet Rollick, Annick; Tully, Thomas

    2015-03-01

    While hematologic reference intervals (RI) are available for multiple raptorial species of the order Accipitriformes and Falconiformes, there is a lack of valuable hematologic information in Strigiformes that can be used for diagnostic and health monitoring purposes. The objective was to report RI in Strigiformes for hematologic variables and to assess agreement between manual cell counting techniques. A multi-center prospective study was designed to assess hematologic RI and blood cell morphology in owl species. Samples were collected from individuals representing 13 Strigiformes species, including Great Horned Owl, Snowy Owl, Eurasian Eagle Owl, Barred Owl, Great Gray Owl, Ural Owl, Northern Saw-Whet Owls, Northern Hawk Owl, Spectacled Owl, Barn Owl, Eastern Screech Owl, Long-Eared Owl, and Short-Eared Owl. Red blood cell count was determined manually using a hemocytometer. White blood cell count was determined using 3 manual counting techniques: (1) phloxine B technique, (2) Natt and Herrick technique, and (3) estimation from the smear. Differential counts and blood cell morphology were determined on smears. Reference intervals were determined and agreement between methods was calculated. Important species-specific differences were observed in blood cell counts and granulocyte morphology. Differences in WBC count between species did not appear to be predictable based on phylogenetic relationships. Overall, most boreal owl species exhibited a lower WBC count than other species. Important disagreements were found between different manual WBC counting techniques. Disagreements observed between manual counting techniques suggest that technique-specific RI should be used in Strigiformes. © 2015 American Society for Veterinary Clinical Pathology.

  5. Cardiac rehabilitation attendance and outcomes in coronary artery disease patients.

    PubMed

    Martin, Billie-Jean; Hauer, Trina; Arena, Ross; Austford, Leslie D; Galbraith, P Diane; Lewin, Adriane M; Knudtson, Merril L; Ghali, William A; Stone, James A; Aggarwal, Sandeep G

    2012-08-07

    Cardiac rehabilitation (CR) is an efficacious yet underused treatment for patients with coronary artery disease. The objective of this study was to determine the association between CR completion and mortality and resource use. We conducted a prospective cohort study of 5886 subjects (20.8% female; mean age, 60.6 years) who had undergone angiography and were referred for CR in Calgary, AB, Canada, between 1996 and 2009. Outcomes of interest included freedom from emergency room visits, hospitalization, and survival in CR completers versus noncompleters, adjusted for clinical covariates, treatment strategy, and coronary anatomy. Hazard ratios for events for CR completers versus noncompleters were also constructed. A propensity model was used to match completers to noncompleters on baseline characteristics, and each outcome was compared between propensity-matched groups. Of the subjects referred for CR, 2900 (49.3%) completed the program, and an additional 554 subjects started but did not complete CR. CR completion was associated with a lower risk of death, with an adjusted hazard ratio of 0.59 (95% confidence interval, 0.49-0.70). CR completion was also associated with a decreased risk of all-cause hospitalization (adjusted hazard ratio, 0.77; 95% confidence interval, 0.71-0.84) and cardiac hospitalization (adjusted hazard ratio, 0.68; 95% confidence interval, 0.55-0.83) but not with emergency room visits. Propensity-matched analysis demonstrated a persistent association between CR completion and reduced mortality. Among those coronary artery disease patients referred, CR completion is associated with improved survival and decreased hospitalization. There is a need to explore reasons for nonattendance and to test interventions to improve attendance after referral.

  6. Assessment of the Thematic Accuracy of Land Cover Maps

    NASA Astrophysics Data System (ADS)

    Höhle, J.

    2015-08-01

    Several land cover maps are generated from aerial imagery and assessed by different approaches. The test site is an urban area in Europe for which six classes (`building', `hedge and bush', `grass', `road and parking lot', `tree', `wall and car port') had to be derived. Two classification methods were applied (`Decision Tree' and `Support Vector Machine') using only two attributes (height above ground and normalized difference vegetation index) which both are derived from the images. The assessment of the thematic accuracy applied a stratified design and was based on accuracy measures such as user's and producer's accuracy, and kappa coefficient. In addition, confidence intervals were computed for several accuracy measures. The achieved accuracies and confidence intervals are thoroughly analysed and recommendations are derived from the gained experiences. Reliable reference values are obtained using stereovision, false-colour image pairs, and positioning to the checkpoints with 3D coordinates. The influence of the training areas on the results is studied. Cross validation has been tested with a few reference points in order to derive approximate accuracy measures. The two classification methods perform equally for five classes. Trees are classified with a much better accuracy and a smaller confidence interval by means of the decision tree method. Buildings are classified by both methods with an accuracy of 99% (95% CI: 95%-100%) using independent 3D checkpoints. The average width of the confidence interval of six classes was 14% of the user's accuracy.

  7. Reference intervals of citrated-native whole blood thromboelastography in premature neonates.

    PubMed

    Motta, Mario; Guaragni, Brunetta; Pezzotti, Elena; Rodriguez-Perez, Carmen; Chirico, Gaetano

    2017-12-01

    Bleeding due to acquired coagulation disorders is a common complication in premature neonates. In this clinical setting, standard coagulation laboratory tests might be unsuitable to investigate the hemostatic function as they reflect the concentration of pro-coagulant proteins but not of anti-coagulant proteins. Thromboelastography (TEG), providing a more complete assessment of hemostasis, may be able to overcome some of these limitations. Unfortunately, experience on the use of TEG in premature neonates is very limited and, in particular in this population, reference ranges of TEG parameters have not been yet evaluated. To evaluate TEG in preterm neonates, and to assess their reference ranges. One hundred and eighteen preterm neonates were analyzed for TEG in a retrospective cohort study. Double-sided 95% reference intervals were calculated using a bootstrap method after Box-Cox transformation. TEG parameters were compared between early-preterm and moderate-/late-preterm neonates and between bleeding and non-bleeding preterm neonates. Comparing early-preterm with moderate-/late-preterm neonates, TEG parameters were not statistically different, except for fibrinolysis which was significantly higher in early preterm neonates. Platelet count significantly correlated with α angle and MA parameters. Bleeding and non-bleeding neonates had similar TEG values. These results reinforce the concept that in stable preterm neonates, in spite of lower concentration of pro- and anti-coagulants proteins, the hemostasis is normally balanced and well functioning. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Publications - GMC 111 | Alaska Division of Geological & Geophysical

    Science.gov Websites

    DGGS GMC 111 Publication Details Title: Vitrinite reflectance data and analysis of the 920 - 8,510 foot Reference Bujak Davies Group, 1989, Vitrinite reflectance data and analysis of the 920 - 8,510 foot interval

  9. Publications - GMC 112 | Alaska Division of Geological & Geophysical

    Science.gov Websites

    foot interval of the Phillips Kerr McGee Sullivan #1 well Authors: Bujak Davies Group Publication Date Reference Bujak Davies Group, 1989, Vitrinite reflectance data and analysis of the 1,070 - 7,870 foot

  10. Publications - GMC 107 | Alaska Division of Geological & Geophysical

    Science.gov Websites

    DGGS GMC 107 Publication Details Title: Vitrinite reflectance data and analysis of the 480 - 9,430 foot Reference Bujak Davies Group, 1989, Vitrinite reflectance data and analysis of the 480 - 9,430 foot interval

  11. [Impact of indirect factors on the growing prevalence of workers with abnormal findings in periodic general health examinations: a survey on the definition and detection of such abnormal workers by occupational health organizations].

    PubMed

    Hoshuyama, T; Takahashi, K; Fujishiro, K; Uchida, K; Okubo, T

    2000-05-01

    The prevalence of workers with abnormal findings in periodic general health examinations (PGHEx) has been growing recently in Japan and reached 41.2% in 1998. To clarify the indirect factors related to such an increase in workers with abnormal findings in the PGHEx, we carried out a questionnaire survey on the content of the statutory notification form of results of the PGHEx among a representative sample of 136 Occupational Health Organizations (OHOs). Questions on how those workers with abnormal findings were defined and detected and when the definition and the reference intervals for total cholesterol became available were included. Of the 107 OHOs which answered the questionnaire, 85 were included in the analyses because they actually calculated the number of workers with abnormal findings in each company and helped the employer fill out the notification form. The results revealed that there was no standardized definition of workers with abnormal findings in the PGHEx. Both reference intervals of items in the PGHEx and algorithm in detecting workers with abnormal findings in the PGHEx varied among the OHOs. When detecting the workers, 13 OHOs (15.3%) selected them taking into consideration medical background factors such as previous results of the PGHEx and current medical treatment. From the late 1980s to the early 1990s, many OHOs modified the definition of workers with abnormal findings, and have tended to reduce the upper limit of the reference interval for serum cholesterol. This is mainly due to amendment of the Industrial Safety and Health Law and a new recommendation for a reference interval/value proposed by the related scientific society. Although the prevalence of workers with abnormal findings in the PGHEx has continuously increased, it is not valid to compare the prevalence over the years because of modification in the definition of such workers. The prevalence of workers with abnormal findings in the PGHEx, which is one of the most important indices of the state of occupational health, should be measured by using an objective definition and be compatible with the future system of health examination for Japanese workers.

  12. Activin B is a novel biomarker for chronic fatigue syndrome/myalgic encephalomyelitis (CFS/ME) diagnosis: a cross sectional study.

    PubMed

    Lidbury, Brett A; Kita, Badia; Lewis, Donald P; Hayward, Susan; Ludlow, Helen; Hedger, Mark P; de Kretser, David M

    2017-03-16

    Investigations of activin family proteins as serum biomarkers for chronic fatigue syndrome/myalgic encephalomyelitis (CFS/ME). CFS/ME is a disease with complex, wide-ranging symptoms, featuring persistent fatigue of 6 months or longer, particularly post exertion. No definitive biomarkers are available. A cross-sectional, observational study of CFS/ME patients fulfilling the 2003 Canadian Consensus Criteria, in parallel with healthy non-fatigued controls, was conducted. Comparisons with a previously defined activin reference population were also performed. For the total study cohort the age range was 18-65 years with a female: male participant ratio of greater than 3:1. All participants were assessed via a primary care community clinic. Blood samples were collected for pathology testing after physical examination and orthostatic intolerance assessment. Cytokines, activin A, activin B and follistatin were also measured in sera from these samples. All data were compared between the CFS/ME and control cohorts, with the activins and follistatin also compared with previously defined reference intervals. Serum activin B levels for CFS/ME participants were significantly elevated when compared to the study controls, as well as the established reference interval. Serum activin A and follistatin were within their normal ranges. All routine and special pathology markers were within the normal laboratory reference intervals for the total study cohort, with no significant differences detected between CFS/ME and control groups. Also, no significant differences were detected for IL-2, IL-4, IL-6, IL-10, IL-17A, TNF or IFN-gamma. Elevated activin B levels together with normal activin A levels identified patients with the diagnostic symptoms of CFS/ME, thus providing a novel serum based test. The activins have multiple physiological roles and capture the diverse array of symptoms experienced by CFS/ME patients.

  13. Hematology and serum biochemistry of Sumatran rhinoceroses (Dicerorhinus sumatrensis) in a rainforest sanctuary in Way Kambas National Park, Indonesia.

    PubMed

    Andriansyah; Candra, Dedi; Riyanto, Marcellus A C T; Barry, Jason; Radcliffe, Robin W

    2013-06-01

    There is a paucity of basic biological information for the Sumatran rhinoceros (Dicerorhinus sumatrensis). This information is fundamental to husbandry and management practices for captive animals and for support of in situ conservation efforts. Serial blood samples were collected over an 8-yr period to evaluate patterns in hematology and serum biochemistry values among five Sumatran rhinoceroses housed at the Sumatran Rhino Sanctuary in Way Kambas National Park, Lampung, Indonesia. Understanding the basis for variance in analytes both within and between subjects can allow use of more sensitive subject-based reference values, and is particularly suitable for small populations of endangered animals. Both intra- and intersubject variability was computed for each analyte and the associated index of individuality was determined. Previously published cutoff points for index of individuality indicate where population-based reference intervals can be used with confidence (index > 1.4) or with caution (0.6 < index < 1.4). Interrhino variability was small for the majority of analytes, with 12 of 19 analytes having an index of individuality greater than 1.4 and none having an index of individuality less than 0.6. With the high within-individual variability of most anayltes in the Sumatran rhinoceroses at the sanctuary, subject-based reference intervals offer little advantage over standard population-based reference intervals for monitoring the health of these endangered animals. Differences were noted (but not tested for statistical significance) in serum urea, aspartate aminotransferase (AST), lactate dehydrogenase (LDH), and cholesterol between young and old rhinoceroses, and in hematocrit, AST, alanine aminotransferase (ALT), LDH, and glucose between male and female rhinoceroses. Husbandry practices, animal management, nutrition and habitat factors may also impact hematology and biochemistry results, and these relationships deserve more careful investigation. This study represents the most comprehensive hematology and serum biochemistry comparison of Sumatran rhinoceroses held in natural rainforest conditions outside a traditional zoological setting.

  14. Detection of human papillomavirus DNA in patients referred to a family practice colposcopy clinic.

    PubMed

    Holman, J R

    1996-01-01

    Human papillomavirus (HPV) is strongly implicated in the pathogenesis of cervical neoplasia. The ability of a commercially available kit (Virapap/Viratype) to detect evidence of HPV is compared with cervical cytology, colposcopy, and directed biopsies. During a period of 16 months, cervical samples from 241 consecutive new patients referred for a colposcopy examination were obtained for HPV-DNA hybridization typing according to the kit instructions. Samples were sent to a reference laboratory for testing. The results were compared with results of the colposcopy examination, cervical cytology, and directed cervical biopsy samples processed and evaluated by our hospital laboratory. HPV DNA was detected in 27 of 107 patients who had abnormal colposcopy findings for a sensitivity of 25 +/- 7.5 percent at the 90 percent confidence interval. One of 134 patients with normal findings was positive for a specificity of 99 +/- 5 percent at the 95 percent confidence interval. Based on a 75 percent probability of HPV in the population, the positive predictive value was 99 percent and the negative predictive value 30 percent. With the low negative predictive value and sensitivity, HPV-DNA testing by this commercial kit is not an adequate tool for screening HPV in this population.

  15. A multicenter nationwide reference intervals study for common biochemical analytes in Turkey using Abbott analyzers.

    PubMed

    Ozarda, Yesim; Ichihara, Kiyoshi; Aslan, Diler; Aybek, Hulya; Ari, Zeki; Taneli, Fatma; Coker, Canan; Akan, Pinar; Sisman, Ali Riza; Bahceci, Onur; Sezgin, Nurzen; Demir, Meltem; Yucel, Gultekin; Akbas, Halide; Ozdem, Sebahat; Polat, Gurbuz; Erbagci, Ayse Binnur; Orkmez, Mustafa; Mete, Nuriye; Evliyaoglu, Osman; Kiyici, Aysel; Vatansev, Husamettin; Ozturk, Bahadir; Yucel, Dogan; Kayaalp, Damla; Dogan, Kubra; Pinar, Asli; Gurbilek, Mehmet; Cetinkaya, Cigdem Damla; Akin, Okhan; Serdar, Muhittin; Kurt, Ismail; Erdinc, Selda; Kadicesme, Ozgur; Ilhan, Necip; Atali, Dilek Sadak; Bakan, Ebubekir; Polat, Harun; Noyan, Tevfik; Can, Murat; Bedir, Abdulkerim; Okuyucu, Ali; Deger, Orhan; Agac, Suret; Ademoglu, Evin; Kaya, Ayşem; Nogay, Turkan; Eren, Nezaket; Dirican, Melahat; Tuncer, GulOzlem; Aykus, Mehmet; Gunes, Yeliz; Ozmen, Sevda Unalli; Kawano, Reo; Tezcan, Sehavet; Demirpence, Ozlem; Degirmen, Elif

    2014-12-01

    A nationwide multicenter study was organized to establish reference intervals (RIs) in the Turkish population for 25 commonly tested biochemical analytes and to explore sources of variation in reference values, including regionality. Blood samples were collected nationwide in 28 laboratories from the seven regions (≥400 samples/region, 3066 in all). The sera were collectively analyzed in Uludag University in Bursa using Abbott reagents and analyzer. Reference materials were used for standardization of test results. After secondary exclusion using the latent abnormal values exclusion method, RIs were derived by a parametric method employing the modified Box-Cox formula and compared with the RIs by the non-parametric method. Three-level nested ANOVA was used to evaluate variations among sexes, ages and regions. Associations between test results and age, body mass index (BMI) and region were determined by multiple regression analysis (MRA). By ANOVA, differences of reference values among seven regions were significant in none of the 25 analytes. Significant sex-related and age-related differences were observed for 10 and seven analytes, respectively. MRA revealed BMI-related changes in results for uric acid, glucose, triglycerides, high-density lipoprotein (HDL)-cholesterol, alanine aminotransferase, and γ-glutamyltransferase. Their RIs were thus derived by applying stricter criteria excluding individuals with BMI >28 kg/m2. Ranges of RIs by non-parametric method were wider than those by parametric method especially for those analytes affected by BMI. With the lack of regional differences and the well-standardized status of test results, the RIs derived from this nationwide study can be used for the entire Turkish population.

  16. Effects of zero reference position on bladder pressure measurements: an observational study.

    PubMed

    Soler Morejón, Caridad De Dios; Lombardo, Tomás Ariel; Tamargo Barbeito, Teddy Osmin; Sandra, Barquín García

    2012-07-05

    Although the World Society for Abdominal Compartment Syndrome in its guidelines recommends midaxillary line (MAL) as zero reference level in intra-abdominal pressure (IAP) measurements in aiming at standardizing the technique, evidence supporting this suggestion is scarce. The aim of this study is to study if the zero reference position influences bladder pressure measurements as estimate for IAP. The IAP of 100 surgical patients was measured during the first 24 h of admission to the surgical intensive care unit of General Calixto Garcia Hospital in Havana (Cuba) following laparotomy. The period was January 2009 to January 2010. The IAP was measured twice with a six-hour interval using the transurethral technique with a priming volume of 25 ml. IAP was first measured with the zero reference level placed at MAL (IAPMAL), followed by a second measurement at the level of the symphysis pubis (SP) after 3 minutes (IAPSP). Correlations were made between IAP and body mass index (BMI), type of surgery, gender, and age. Mean IAPMAL was 8.5 ± 2.8 mmHg vs. IAPSP 6.5 ± 2.8 mmHg (p < 0.0001). The bias between measurements was 2.0 ± 1.5, 95% confidence interval of 1.4 to 3.0, upper limit of 4.9, lower limit of -0.9, and a percentage error of 35.1%. IAPMAL was consistently higher than IAPSP regardless of the type of surgery. The BMI correlated with IAP values regardless of the zero reference level (R2 = 0.4 and 0.3 with IAPMAL and IAPSP respectively, p < 0.0001). The zero reference level has an important impact on IAP measurement in surgical patients after laparotomy and can potentially lead to over or underestimation. Further anthropometric studies are needed with regard to the relative MAL and SP zero reference position in relation to the theoretical ideal reference level at midpoint of the abdomen. Until better evidence is available, MAL remains the recommended zero reference position due to its best anatomical localization at iliac crest.

  17. Effects of zero reference position on bladder pressure measurements: an observational study

    PubMed Central

    2012-01-01

    Background Although the World Society for Abdominal Compartment Syndrome in its guidelines recommends midaxillary line (MAL) as zero reference level in intra-abdominal pressure (IAP) measurements in aiming at standardizing the technique, evidence supporting this suggestion is scarce. The aim of this study is to study if the zero reference position influences bladder pressure measurements as estimate for IAP. Methods The IAP of 100 surgical patients was measured during the first 24 h of admission to the surgical intensive care unit of General Calixto Garcia Hospital in Havana (Cuba) following laparotomy. The period was January 2009 to January 2010. The IAP was measured twice with a six-hour interval using the transurethral technique with a priming volume of 25 ml. IAP was first measured with the zero reference level placed at MAL (IAPMAL), followed by a second measurement at the level of the symphysis pubis (SP) after 3 minutes (IAPSP). Correlations were made between IAP and body mass index (BMI), type of surgery, gender, and age. Results Mean IAPMAL was 8.5 ± 2.8 mmHg vs. IAPSP 6.5 ± 2.8 mmHg (p < 0.0001). The bias between measurements was 2.0 ± 1.5, 95% confidence interval of 1.4 to 3.0, upper limit of 4.9, lower limit of -0.9, and a percentage error of 35.1%. IAPMAL was consistently higher than IAPSP regardless of the type of surgery. The BMI correlated with IAP values regardless of the zero reference level (R2 = 0.4 and 0.3 with IAPMAL and IAPSP respectively, p < 0.0001). Conclusions The zero reference level has an important impact on IAP measurement in surgical patients after laparotomy and can potentially lead to over or underestimation. Further anthropometric studies are needed with regard to the relative MAL and SP zero reference position in relation to the theoretical ideal reference level at midpoint of the abdomen. Until better evidence is available, MAL remains the recommended zero reference position due to its best anatomical localization at iliac crest. PMID:22873414

  18. Clinical pathology of llamas and alpacas.

    PubMed

    Tornquist, Susan J

    2009-07-01

    Clinical laboratory data including hematology, hemostasis, biochemical, and cytologic findings contribute to diagnosis and monitoring of numerous conditions in camelids. Establishment of reference intervals and descriptions of normal components of fluids in these species have improved our ability to interpret test results.

  19. A new reference section for palynostratigraphic zonation of Paleocene rocks in the Rocky Mountain region

    USGS Publications Warehouse

    Nichols, D.J.; Flores, R.M.

    2006-01-01

    A biostratigraphic (palynostratigraphic) zonation of Paleocene rocks was established in the northeastern Wind River Basin near Waltman, Natrona County, Wyoming, in 1978 and subsequently applied extensively by various workers throughout the Rocky Mountain region. Because the original study on which the zonation was based was proprietary, precise details about the locations of the two reference sections and the samples on which the zonation was based were not published and are no longer retrievable. Therefore, it is useful (although not required) to designate formally a new reference section for the Paleocene biozones. Accordingly, exposures of Paleocene and associated strata within and west of the Castle Gardens Petroglyph Site in Fremont County, Wyoming, in the east-central part of the Wind River Basin, were selected for this purpose. At this location, composite stratigraphic sections encompassing 740 m of strata were measured, described, and sampled. Productive samples yielded characteristic Maastrichtian palynomorphs from the lower part of the sampled interval and diagnostic species of the six palynological biozones zones widely known as P1 (lower Paleocene) through P6 (upper Paleocene), through an interval of about 580 m. The Paleocene biozones are present in the same consistent stratigraphic order in the Castle Gardens area as observed in the 1978 study and subsequent studies throughout the Rocky Mountain region. In accordance with the North American Stratigraphic Code, the historical background is presented; intent to establish the Castle Gardens reference section is declared; the category, rank, and formal names of biostratigraphic units within it are specified; and the features of the biozonation are described, including biozone boundaries, ages, and regional relations. Occurrences of biostratigraphically significant palynological species within each biozone in the reference section are tabulated, and presence of these and other species in correlative biozones are discussed. The new reference section in the Castle Gardens area replaces the original reference sections near Waltman and provides a better-documented foundation for Paleocene palynostratigraphy in the Rocky Mountain region.

  20. Sickle cell disease: reference values and interhemispheric differences of nonimaging transcranial Doppler blood flow parameters.

    PubMed

    Arkuszewski, M; Krejza, J; Chen, R; Kwiatkowski, J L; Ichord, R; Zimmerman, R; Ohene-Frempong, K; Desiderio, L; Melhem, E R

    2011-09-01

    TCD screening is widely used to identify children with SCD at high risk of stroke. Those with high mean flow velocities in major brain arteries have increased risk of stroke. Thus, our aim was to establish reference values of interhemispheric differences and ratios of blood flow Doppler parameters in the tICA, MCA, and ACA as determined by conventional TCD in children with sickle cell anemia. Reference limits of blood flow parameters were established on the basis of a consecutive cohort of 56 children (mean age, 100 ± 40 months; range, 29-180 months; 30 females) free of neurologic deficits and intracranial stenosis detectable by MRA, with blood flow velocities <170 cm/s by conventional TCD. Reference limits were estimated by using tolerance intervals, within which are included with a probability of .90 of all possible data values from 95% of a population. Average peak systolic velocities were significantly higher in the right hemisphere in the MCA and ACA (185 ± 28 cm/s versus 179 ± 27 and 152 ± 30 cm/s versus 143 ± 34 cm/s respectively). Reference limits for left-to-right differences in the mean flow velocities were the following: -43 to 33 cm/s for the MCA; -49 to 38 cm/s for the ACA, and -38 to 34 cm/s for the tICA, respectively. Respective reference limits for left-to-right velocity ratios were the following: 0.72 to 1.25 cm/s for the MCA; 0.62 to 1.39 cm/s for the ACA, and 0.69 to 1.27 cm/s for the tICA. Flow velocities in major arteries were inversely related to age and Hct or Hgb. The study provides reference intervals of TCD flow velocities and their interhemispheric differences and ratios that may be helpful in identification of intracranial arterial stenosis in children with SCD undergoing sonographic screening for stroke prevention.

  1. INNOVATIVE TECHNOLOGY EVALUATION REPORT ...

    EPA Pesticide Factsheets

    The Russian Peat Borer designed and fabricated by Aquatic Research Instruments was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation Program in April and May 1999 at sites in EPA Regions 1 and 5, respectively. In addition to assessing ease of sampler operation, key objectives of the demonstration included evaluating the sampler?s ability to (1) consistently collect a given volume of sediment, (2) consistently collect sediment in a given depth interval, (3) collect samples with consistent characteristics from a homogenous layer of sediment, and (4) collect samples under a variety of site conditions. This report describes the demonstration results for the Russian Peat Borer and two conventional samplers (the Hand Corer and Vibrocorer) used as reference samplers. During the demonstration, the Russian Peat Borer was the only sampler that collected samples in the deep depth interval (4 to 11 feet below sediment surface). It collected representative and relatively uncompressed core samples of consolidated sediment in discrete depth intervals. The reference samplers collected relatively compressed samples of both consolidated and unconsolidated sediments from the sediment surface downward; sample representativeness may be questionable because of core shortening and core compression. Sediment stratification was preserved only for consolidated sediment samples collected by the Russian Peat Borer but for bo

  2. A PCT-wide collaborative clinical audit selecting recall intervals for patients according to risk.

    PubMed

    Cannell, P J

    2011-03-26

    This audit was carried out to assess the level to which recall intervals were individually and appropriately selected for patients attending dental practices across a primary care trust (PCT) area in Essex. A retrospective audit was carried out by reference to patient records to assess various criteria, including whether patients were categorised according to risk of oral disease, whether an appropriate recall had been selected and whether a discussion regarding a recall interval had been undertaken. An educational event highlighting the issue of recall intervals was held. Subsequent to this a prospective audit was undertaken to assess relevant criteria. Prospective audit data showed a marked increase in the use of patient risk assessments for caries, periodontal disease, oral cancer and non-carious tooth surface loss (NCTSL). Recall intervals were also more often selected based on a patient's risk status and discussed with the patient compared to that observed in the retrospective audit data. This audit was successful as a tool to bring about change in the behaviour of dentists regarding their determination of appropriate recall intervals for patients. Whether that change in behaviour is long-term or transient requires further investigation.

  3. Sustainable intersection control to accommodate urban freight mobility.

    DOT National Transportation Integrated Search

    2009-08-01

    In this research, we studied green extension of a two-phased vehicleactuated signal at an isolated : intersection between two one-way streets. The green phase is extended by a preset time interval, referred to : as critical gap, from the time of a...

  4. Quantitative Nondestructive Evaluation

    DTIC Science & Technology

    1979-10-01

    reliability has been discussed by a number of researchers, including Pachman, et. al. [25,28], Hastings [29], Ehret [30], Kaplan and Reiman [31], and...123 REFERENCES (Continued) 31. Kaplan, M.P. and Reiman , J.A. "Use of Fracture Mechanics in Estimating Structural Life and Inspection Intervals

  5. Adaptation in the auditory midbrain of the barn owl (Tyto alba) induced by tonal double stimulation.

    PubMed

    Singheiser, Martin; Ferger, Roland; von Campenhausen, Mark; Wagner, Hermann

    2012-02-01

    During hunting, the barn owl typically listens to several successive sounds as generated, for example, by rustling mice. As auditory cells exhibit adaptive coding, the earlier stimuli may influence the detection of the later stimuli. This situation was mimicked with two double-stimulus paradigms, and adaptation was investigated in neurons of the barn owl's central nucleus of the inferior colliculus. Each double-stimulus paradigm consisted of a first or reference stimulus and a second stimulus (probe). In one paradigm (second level tuning), the probe level was varied, whereas in the other paradigm (inter-stimulus interval tuning), the stimulus interval between the first and second stimulus was changed systematically. Neurons were stimulated with monaural pure tones at the best frequency, while the response was recorded extracellularly. The responses to the probe were significantly reduced when the reference stimulus and probe had the same level and the inter-stimulus interval was short. This indicated response adaptation, which could be compensated for by an increase of the probe level of 5-7 dB over the reference level, if the latter was in the lower half of the dynamic range of a neuron's rate-level function. Recovery from adaptation could be best fitted with a double exponential showing a fast (1.25 ms) and a slow (800 ms) component. These results suggest that neurons in the auditory system show dynamic coding properties to tonal double stimulation that might be relevant for faithful upstream signal propagation. Furthermore, the overall stimulus level of the masker also seems to affect the recovery capabilities of auditory neurons. © 2012 The Authors. European Journal of Neuroscience © 2012 Federation of European Neuroscience Societies and Blackwell Publishing Ltd.

  6. Evaluation of plasma fibrinogen concentration as a diagnostic indicator of inflammation in red-eared sliders (Trachemys scripta elegans).

    PubMed

    Moore, A Russell; Allender, Matthew C; Mitchell, Mark A; MacNeill, Amy L

    2015-01-15

    To critically evaluate plasma fibrinogen concentration as a diagnostic indicator of inflammation in red-eared sliders (Trachemys scripta elegans). Prospective induced-disease model and prospective cross-sectional study. Plasma samples from 12 purpose-bred red-eared sliders and 153 farm-raised red-eared sliders. A modification of the Jacobsson method was developed to measure fibrinogen concentration in platelet-poor plasma from red-eared sliders. Purpose-bred turtles had been inoculated with a ranavirus (n = 4) or sterile PBS solution (8) as part of another study. Farm-raised red-eared sliders were categorized as healthy (n = 138) or overtly ill (15) on the basis of physical examination findings at the time of blood sample collection. Samples from 124 of the 138 healthy red-eared sliders were used to establish a fibrinogen concentration reference interval as measured by the modified Jacobsson method. Fibrinogen concentrations in ranavirus-infected and physically ill turtles were compared with those of healthy turtles to determine whether fibrinogen concentration would be a useful diagnostic indicator of inflammation in red-eared sliders. The modified Jacobsson method was reliably used to measure fibrinogen concentration. The fibrinogen concentration reference interval from healthy reproductively active female red-eared sliders was right skewed. Fibrinogen concentration did not differ significantly between healthy red-eared sliders and ranavirus-infected or overtly ill red-eared sliders. A reference interval for red-eared slider plasma fibrinogen concentration was established and partitioned by sex to account for considerable right skewing observed for females. Fibrinogen concentration was not a useful indicator of inflammation in red-eared sliders with ranavirus infection or other overt illnesses.

  7. Serum Beta Hydroxybutyrate Concentrations in Cats with Chronic Kidney Disease, Hyperthyroidism, or Hepatic Lipidosis.

    PubMed

    Gorman, L; Sharkey, L C; Armstrong, P J; Little, K; Rendahl, A

    2016-01-01

    Ketones, including beta hydroxybutyrate (BHB), are produced in conditions of negative energy balance and decreased glucose utilization. Serum BHB concentrations in cats are poorly characterized in diseases other than diabetes mellitus. Serum BHB concentrations will be increased in cats with chronic kidney disease (CKD), hyperthyroidism (HT), or hepatic lipidosis (HL). Twenty-eight client-owned cats with CKD, 34 cats with HT, and 15 cats with HL; 43 healthy cats. Prospective observational study. Serum BHB concentrations were measured at admission in cats with CKD, HT, and HL, for comparison with a reference interval established using healthy cats. Results of dipstick urine ketone measurement, when available, were compared to BHB measurement. Beta hydroxybutyrate was above the reference interval (<0.11 mmol/L) in 6/28 cats (21%) with CKD, 7/34 cats (20%) with HT, and 11/15 cats (73%) with HL, significantly exceeding the expected 2.5% above the reference interval for healthy cats (P < .001 for all groups). Elevations were mild in CKD and HT groups (median BHB 0.1 mmol/L for both groups, 80th percentile 0.12 and 0.11 mmol/L, respectively), but more marked in HL cats (median BHB 0.2 mmol/L, 80th percentile 0.84 mmol/L). None of 11 cats with increased serum BHB concentration having urine dipstick analysis performed within 24 h of sampling for BHB were ketonuric. Increases in serum BHB concentrations occur in cats with CKD, HT, and HL, and might provide an useful index of catabolism. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  8. Automated HPLC assay for urinary collagen cross-links: effect of age, menopause, and metabolic bone diseases.

    PubMed

    Kraenzlin, Marius E; Kraenzlin, Claude A; Meier, Christian; Giunta, Cecilia; Steinmann, Beat

    2008-09-01

    The pyridinium cross-links pyridinoline (PYD) and deoxypyridinoline (DPD) are established markers of bone resorption. We evaluated the analytical and clinical performance of a commercially available PYD HPLC assay and established reference intervals in children and adults. We used a commercially available reagent set (Chromsystems Instruments & Chemicals) to measure PYD and DPD in 319 healthy controls (156 premenopausal women, 80 healthy men, and 83 healthy children age 1 month to 14 years) and 397 patients with metabolic bone diseases (postmenopausal osteoporosis, n = 175; male osteoporosis, n = 176; hyperparathyroidism, n = 17; hyperthyroidism, n = 19; Paget disease, n = 10). The mean intraassay and interassay CVs were <6% and <8% for both PYD and DPD, respectively. The reference interval was constant for premenopausal women in the age group 20-49 years. In men, cross-link values peaked at 20-29 years and decreased thereafter. Women with postmenopausal osteoporosis had significantly higher PYD (51%) and DPD (58%) values compared to premenopausal women. Similar results were found in osteoporotic men. In children the highest values were found in the first weeks and months after birth, followed by a decrease of 50%-60% at age 11-14 years. In metabolic bone diseases cross-link concentrations were significantly increased. The DPD:PYD ratio (mean value approximately 0.2) was remarkably constant in all populations evaluated. The automated HPLC assay is a precise and convenient method for PYD and DPD measurement. We established reference intervals for adult women and men and for children up to 14 years old. The cross-link concentrations we determined by use of this HPLC method confirm its clinical value in enabling identification of increased bone resorption in patients with metabolic bone diseases.

  9. Echocardiographic Assessment of Left Atrial Size and Function in Warmblood Horses: Reference Intervals, Allometric Scaling, and Agreement of Different Echocardiographic Variables.

    PubMed

    Huesler, I M; Mitchell, K J; Schwarzwald, C C

    2016-07-01

    Echocardiographic assessment of left atrial (LA) size and function in horses is not standardized. The aim of this study was to establish reference intervals for echocardiographic indices of LA size and function in Warmblood horses and to provide proof of concept for allometric scaling of variables and for the clinical use of area-based indices. Thirty-one healthy Warmblood horses and 91 Warmblood horses with a primary diagnosis of mitral regurgitation (MR) or aortic regurgitation (AR). Retrospective study. Echocardiographic indices of LA size and function were measured and scaled to body weight (BWT). Reference intervals were calculated, the influence of BWT, age, and valvular regurgitation on LA size and function was investigated and agreement between different measurements of LA size was assessed. Allometric scaling of variables of LA size allowed for correction of differences in BWT. Indices of LA size documented LA enlargement with moderate and severe MR and AR, whereas most indices of LA mechanical function were not significantly altered by valvular regurgitation. Different indices of LA size were in fair to good agreement but still lead to discordant conclusions with regard to assessment of LA enlargement in individual horses. Allometric scaling of echocardiographic variables of LA size is advised to correct for differences in BWT among Warmblood horses. Assessment of LA dimensions should be based on an integrative approach combining subjective evaluation and assessment of multiple measurements, including area-based variables. The clinical relevance of indices of LA mechanical function remains unclear when used in horses with mitral or aortic regurgitation. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  10. A Case-Crossover Study of Heat Exposure and Injury Risk in Outdoor Agricultural Workers.

    PubMed

    Spector, June T; Bonauto, David K; Sheppard, Lianne; Busch-Isaksen, Tania; Calkins, Miriam; Adams, Darrin; Lieblich, Max; Fenske, Richard A

    2016-01-01

    Recent research suggests that heat exposure may increase the risk of traumatic injuries. Published heat-related epidemiological studies have relied upon exposure data from individual weather stations. To evaluate the association between heat exposure and traumatic injuries in outdoor agricultural workers exposed to ambient heat and internal heat generated by physical activity using modeled ambient exposure data. A case-crossover study using time-stratified referent selection among 12,213 outdoor agricultural workers with new Washington State Fund workers' compensation traumatic injury claims between 2000 and 2012 was conducted. Maximum daily Humidex exposures, derived from modeled meteorological data, were assigned to latitudes and longitudes of injury locations on injury and referent dates. Conditional logistic regression was used to estimate odds ratios of injury for a priori daily maximum Humidex categories. The mean of within-stratum (injury day and corresponding referent days) standard deviations of daily maximum Humidex was 4.8. The traumatic injury odds ratio was 1.14 (95% confidence interval 1.06, 1.22), 1.15 (95% confidence interval 1.06, 1.25), and 1.10 (95% confidence interval 1.01, 1.20) for daily maximum Humidex of 25-29, 30-33, and ≥34, respectively, compared to < 25, adjusted for self-reported duration of employment. Stronger associations were observed during cherry harvest duties in the June and July time period, compared to all duties over the entire study period. Agricultural workers laboring in warm conditions are at risk for heat-related traumatic injuries. Combined heat-related illness and injury prevention efforts should be considered in high-risk populations exposed to warm ambient conditions in the setting of physical exertion.

  11. Effects of Visual Feedback and Memory on Unintentional Drifts in Performance During Finger Pressing Tasks

    PubMed Central

    Solnik, Stanislaw; Qiao, Mu; Latash, Mark L.

    2017-01-01

    This study tested two hypotheses on the nature of unintentional force drifts elicited by removing visual feedback during accurate force production tasks. The role of working memory (memory hypothesis) was explored in tasks with continuous force production, intermittent force production, and rest intervals over the same time interval. The assumption of unintentional drifts in referent coordinate for the fingertips was tested using manipulations of visual feedback: Young healthy subjects performed accurate steady-state force production tasks by pressing with the two index fingers on individual force sensors with visual feedback on the total force, sharing ratio, both, or none. Predictions based on the memory hypothesis have been falsified. In particular, we observed consistent force drifts to lower force values during continuous force production trials only. No force drift or drifts to higher forces were observed during intermittent force production trials and following rest intervals. The hypotheses based on the idea of drifts in referent finger coordinates have been confirmed. In particular, we observed superposition of two drift processes: A drift of total force to lower magnitudes and a drift of the sharing ratio to 50:50. When visual feedback on total force only was provided, the two finger forces showed drifts in opposite directions. We interpret the findings as evidence for the control of motor actions with changes in referent coordinates for participating effectors. Unintentional drifts in performance are viewed as natural relaxation processes in the involved systems; their typical time reflects stability in the direction of the drift. The magnitude of the drift was higher in the right (dominant) hand, which is consistent with the dynamic dominance hypothesis. PMID:28168396

  12. Highly sensitive measurement of whole blood chromium by inductively coupled plasma mass spectrometry.

    PubMed

    Cieslak, Wendy; Pap, Kathleen; Bunch, Dustin R; Reineks, Edmunds; Jackson, Raymond; Steinle, Roxanne; Wang, Sihe

    2013-02-01

    Chromium (Cr), a trace metal element, is implicated in diabetes and cardiovascular disease. A hypochromic state has been associated with poor blood glucose control and unfavorable lipid metabolism. Sensitive and accurate measurement of blood chromium is very important to assess the chromium nutritional status. However, interferents in biological matrices and contamination make the sensitive analysis challenging. The primary goal of this study was to develop a highly sensitive method for quantification of total Cr in whole blood by inductively coupled plasma mass spectrometry (ICP-MS) and to validate the reference interval in a local healthy population. This method was developed on an ICP-MS with a collision/reaction cell. Interference was minimized using both kinetic energy discrimination between the quadrupole and hexapole and a selective collision gas (helium). Reference interval was validated in whole blood samples (n=51) collected in trace element free EDTA tubes from healthy adults (12 males, 39 females), aged 19-64 years (38.8±12.6), after a minimum of 8 h fasting. Blood samples were aliquoted into cryogenic vials and stored at -70 °C until analysis. The assay linearity was 3.42 to 1446.59 nmol/L with an accuracy of 87.7 to 99.8%. The high sensitivity was achieved by minimization of interference through selective kinetic energy discrimination and selective collision using helium. The reference interval for total Cr using a non-parametric method was verified to be 3.92 to 7.48 nmol/L. This validated ICP-MS methodology is highly sensitive and selective for measuring total Cr in whole blood. Copyright © 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved. Published by Elsevier Inc. All rights reserved.

  13. Reference values for serum leptin in healthy non-obese children and adolescents.

    PubMed

    Lausten-Thomsen, Ulrik; Christiansen, Michael; Louise Hedley, Paula; Esmann Fonvig, Cilius; Stjernholm, Theresa; Pedersen, Oluf; Hansen, Torben; Holm, Jens-Christian

    2016-11-01

    Adipokines are biologically active, low-molecular weight peptides, which play a major role in metabolic homeostasis in humans. Leptin has gained increasing attention in pediatrics as a biomarker for various metabolic pathologies. Yet, its usefulness is hampered by the relative lack of reference values from pediatric settings. Accordingly, this study aims to evaluate serum concentrations of leptin, soluble leptin receptor (sOB-R), and free leptin index (FLI) in healthy Danish schoolchildren aged 6-18 years and subsequently to establish reference intervals across sex and age groups. A total of 1193 healthy, non-obese Danish schoolchildren (730 girls, 463 boys) aged 6-18 years (median 11.9) were examined by trained medical staff. Serum leptin and sOB-R concentrations in venous fasting blood samples were quantitated by immunoassay. Percentile curves of leptin, sOB-R, and free leptin index were calculated using the General Additive Model for Location Scale and Shape (GAMLSS). Significant age and sex-dependent differences in circulating leptin levels were found. In boys, the median leptin concentration for all ages combined was 3.35 μg/L (95%-interval: 0.71-22.47) and in girls, it was 9.89 ng/L (95%-interval: 2.06-41.49). For SOB-R, no sex-specific difference was found, and the median sOB-R concentration was 8.24 μg/L (IQR: 3.58-23.74; range: < 1.56-744.15). We demonstrated an age-dependent correlation with both serum leptin concentration and free leptin index with a gradual and significant increase in girls throughout childhood and adolescence and a significantly higher leptin concentration and free leptin index bell-shaped peak in early adolescence in boys.

  14. Longitudinal evaluation of thyroid autoimmunity and function in pregnant Korean women.

    PubMed

    Han, Seong-Min; Han, Jeong Hee; Park, Jina A; Quinn, Frank A; Park, Joonseok; Oh, Eunsuk

    2013-12-01

    Maternal thyroid dysfunction during pregnancy has been associated with adverse outcomes for both the mother and child. For this reason, it is important to understand thyroid status in pregnant women. However, there are relatively few published studies that examine thyroid function tests (TFT) and thyroid autoimmunity in non-Western pregnant women. Serum samples were longitudinally collected throughout pregnancy from 108 Korean women. TFT, thyroid peroxidase antibodies (TPO-Ab), and thyroglobulin antibodies (Tg-Ab) testing was performed. The impact of gestational age on TPO-Ab and Tg-Ab levels was evaluated and gestational age-specific reference intervals for TFT were established in antibody negative women. In the first trimester, TPO-Ab and Tg-Ab were positive in 13.9% and 16.7% of women, respectively. For antibody positive women, median autoantibody levels for TPO-Ab and Tg-Ab dropped from first trimester to near term (133.7-10.5 IU/mL, and 162.1-21.9 IU/mL, respectively). Antibody status influenced thyroid stimulating hormone (TSH) during the first trimester, and TSH, free T4 (FT4) and total T4 (TT4) in the early second trimester. Later in gestation, no significant differences in TFT were found based on antibody status. Gestational age-specific reference intervals for TFT were calculated in antibody negative women. Laboratory evidence of autoimmune thyroid disease (AITD) is common in this population of pregnant Korean women. Antibody status influences TFT values in the first and early second trimester. Thyroid autoantibody status and titer change in an individual-specific manner throughout pregnancy. Gestational age-specific reference intervals should be utilized for interpretation of TFT results in pregnant women.

  15. Survey of point-of-care instrumentation, analysis, and quality assurance in veterinary practice.

    PubMed

    Bell, Regan; Harr, Kendal; Rishniw, Mark; Pion, Paul

    2014-06-01

    While there have been ASVCP meeting discussions regarding quality assurance plans and lack thereof for in-clinic analyzers, there are little published data regarding in-clinic quality assurance and control practices. The purpose of this study was the identification of the common equipment used in hematologic, biochemical, urinalysis, and other testing, and assessment of quality control and assurance programs currently being performed in-clinic. All members of the Veterinary Information Network (VIN) were solicited to participate in an online survey between July and September 2007. In total, 452 complete or partial responses were received. Eighty-nine percent of respondents (361/404) said that veterinary technicians (unlicensed, licensed, and registered) performed the majority of analyses. Eighty-eight percent (366/417) of respondents performed some quality assurance on their laboratory equipment, most commonly on chemistry (91%, 324/357), and hematology (84%, 292/347) analyzers, and least commonly on fecal analyses (57%, 148/260) and ELISA assays (25%, 65/256). Ignorance of how to perform quality assurance was the most commonly stated reason (49%, 25/51) for lack of a quality assurance program. The majority of practices (316/374) utilized manufacturer-provided reference intervals without further adjustment or assessment. Roughly one-third of respondents (126/374) used reference intervals from textbooks, which is discouraged by ASVCP guidelines. This study found that the majority of respondents were not in compliance with ASVCP guidelines, illustrating the need for improved education of technical staff, veterinary students, and veterinarians regarding limitations of in-clinic laboratory equipment and the importance of regular quality control, maintenance, training, and reference interval development. © 2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.

  16. Development and validation of a competitive enzyme-linked immunosorbent assay for the measurement of total plasma immunoglobulins in healthy loggerhead sea (Caretta caretta) and green turtles (Chelonia mydas).

    PubMed

    Kaplan, Amy J; Stacy, Nicole I; Jacobson, Elliott; Le-Bert, Carolina R; Nollens, Hendrik H; Origgi, Francesco C; Green, Linda G; Bootorabi, Shadi; Bolten, Alan; Hernandez, Jorge A

    2016-01-01

    The quantification of circulating plasma immunoglobulins represents a valuable diagnostic tool in human and veterinary immunology, although its application is very limited in reptile medicine to date. The objectives of our study were the development and standardization of a competitive enzyme-linked immunosorbent assay (cELISA) for the measurement of total plasma immunoglobulins (Igs; both IgM and IgY) in loggerhead sea turtles (LST; Caretta caretta; n = 254) and green turtles (GT; Chelonia mydas; n = 111), the establishment of reference intervals for Ig for both species, and the examination of associations between Ig and total protein (TP), condition index, and water temperature. The cELISA for Ig was successfully developed and optimized. Reference intervals for Ig were 0.38-0.94 g/dL in LST (median: 0.59 g/dL; range: 0.16-2.15 g/dL) and 0.40-0.85 g/dL in GT (median: 0.58 g/dL; range: 0.18-1.80 g/dL). In LST, there were positive linear relationships of Ig with TP, and TP with Ig and condition index, and a negative relationship of Ig with condition index. The positive linear relationships of Ig with TP, and TP with Ig were also identified in GT. These positive associations of Ig and TP were expected, as Ig represents fractions of TP, and TP reportedly increases with straight carapace length and weight. The negative association of Ig with condition index may indicate potential biological variations. The cELISA and reference intervals for total Ig of LST and GT presented herein have the potential to be useful as a diagnostic and research tool for sea turtle immunology. © 2015 The Author(s).

  17. Feeding Intervals in Premature Infants ≤1750 g: An Integrative Review.

    PubMed

    Binchy, Áine; Moore, Zena; Patton, Declan

    2018-06-01

    The timely establishment of enteral feeds and a reduction in the number of feeding interruptions are key to achieving optimal nutrition in premature infants. Nutritional guidelines vary widely regarding feeding regimens and there is not a widely accepted consensus on the optimal feeding interval. To critically examine the evidence to determine whether there is a relationship to feeding intervals and feeding outcomes in premature infants. A systematic review of the literature in the following databases: PubMed, CINAHL, Embase and the Cochrane Library. The search strategy used the terms infant premature, low birth weight, enteral feeding, feed tolerance and feed intervals. Search results yielded 10 studies involving 1269 infants (birth weight ≤1750 g). No significant differences in feed intolerance, growth, or incidence of necrotizing enterocolitis were observed. Evidence suggests that infants fed at 2 hourly intervals reached full feeds faster than at 3 hourly intervals, had fewer days on parenteral nutrition, and fewer days in which feedings were withheld. Decrease in the volume of gastric residuals and feeding interruptions were observed in the infants fed at 3 hourly intervals than those who were continuously fed. Reducing the feed interval from 3 to 2 hourly increases nurse workload, yet may improve feeding outcomes by reducing the time to achieve full enteral feeding. Studies varied greatly in the definition and management of feeding intolerance and in how outcomes were measured, analyzed, and reported. The term "intermittent" is used widely but can refer to a 2 or 3 hourly interval.

  18. Modulation of human time processing by subthalamic deep brain stimulation.

    PubMed

    Wojtecki, Lars; Elben, Saskia; Timmermann, Lars; Reck, Christiane; Maarouf, Mohammad; Jörgens, Silke; Ploner, Markus; Südmeyer, Martin; Groiss, Stefan Jun; Sturm, Volker; Niedeggen, Michael; Schnitzler, Alfons

    2011-01-01

    Timing in the range of seconds referred to as interval timing is crucial for cognitive operations and conscious time processing. According to recent models of interval timing basal ganglia (BG) oscillatory loops are involved in time interval recognition. Parkinsońs disease (PD) is a typical disease of the basal ganglia that shows distortions in interval timing. Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is a powerful treatment of PD which modulates motor and cognitive functions depending on stimulation frequency by affecting subcortical-cortical oscillatory loops. Thus, for the understanding of BG-involvement in interval timing it is of interest whether STN-DBS can modulate timing in a frequency dependent manner by interference with oscillatory time recognition processes. We examined production and reproduction of 5 and 15 second intervals and millisecond timing in a double blind, randomised, within-subject repeated-measures design of 12 PD-patients applying no, 10-Hz- and ≥ 130-Hz-STN-DBS compared to healthy controls. We found under(re-)production of the 15-second interval and a significant enhancement of this under(re-)production by 10-Hz-stimulation compared to no stimulation, ≥ 130-Hz-STN-DBS and controls. Milliseconds timing was not affected. We provide first evidence for a frequency-specific modulatory effect of STN-DBS on interval timing. Our results corroborate the involvement of BG in general and of the STN in particular in the cognitive representation of time intervals in the range of multiple seconds.

  19. Modulation of Human Time Processing by Subthalamic Deep Brain Stimulation

    PubMed Central

    Timmermann, Lars; Reck, Christiane; Maarouf, Mohammad; Jörgens, Silke; Ploner, Markus; Südmeyer, Martin; Groiss, Stefan Jun; Sturm, Volker; Niedeggen, Michael; Schnitzler, Alfons

    2011-01-01

    Timing in the range of seconds referred to as interval timing is crucial for cognitive operations and conscious time processing. According to recent models of interval timing basal ganglia (BG) oscillatory loops are involved in time interval recognition. Parkinsońs disease (PD) is a typical disease of the basal ganglia that shows distortions in interval timing. Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is a powerful treatment of PD which modulates motor and cognitive functions depending on stimulation frequency by affecting subcortical-cortical oscillatory loops. Thus, for the understanding of BG-involvement in interval timing it is of interest whether STN-DBS can modulate timing in a frequency dependent manner by interference with oscillatory time recognition processes. We examined production and reproduction of 5 and 15 second intervals and millisecond timing in a double blind, randomised, within-subject repeated-measures design of 12 PD-patients applying no, 10-Hz- and ≥130-Hz-STN-DBS compared to healthy controls. We found under(re-)production of the 15-second interval and a significant enhancement of this under(re-)production by 10-Hz-stimulation compared to no stimulation, ≥130-Hz-STN-DBS and controls. Milliseconds timing was not affected. We provide first evidence for a frequency-specific modulatory effect of STN-DBS on interval timing. Our results corroborate the involvement of BG in general and of the STN in particular in the cognitive representation of time intervals in the range of multiple seconds. PMID:21931767

  20. Comparing Physical Examination With Sonographic Versions of the Same Examination Techniques for Splenomegaly.

    PubMed

    Cessford, Tara; Meneilly, Graydon S; Arishenkoff, Shane; Eddy, Christopher; Chen, Luke Y C; Kim, Daniel J; Ma, Irene W Y

    2017-12-08

    To determine whether sonographic versions of physical examination techniques can accurately identify splenomegaly, Castell's method (Ann Intern Med 1967; 67:1265-1267), the sonographic Castell's method, spleen tip palpation, and the sonographic spleen tip technique were compared with reference measurements. Two clinicians trained in bedside sonography patients recruited from an urban hematology clinic. Each patient was examined for splenomegaly using conventional percussion and palpation techniques (Castell's method and spleen tip palpation, respectively), as well as the sonographic versions of these maneuvers (sonographic Castell's method and sonographic spleen tip technique). Results were compared with a reference standard based on professional sonographer measurements. The sonographic Castell's method had greater sensitivity (91.7% [95% confidence interval, 61.5% to 99.8%]) than the traditional Castell's method (83.3% [95% confidence interval, 51.6% to 97.9%]) but took longer to perform [mean ± SD, 28.8 ± 18.6 versus 18.8 ± 8.1 seconds; P = .01). Palpable and positive sonographic spleen tip results were both 100% specific, but the sonographic spleen tip method was more sensitive (58.3% [95% confidence interval, 27.7% to 84.8%] versus 33.3% [95% confidence interval, 9.9% to 65.1%]). Sonographic versions of traditional physical examination maneuvers have greater diagnostic accuracy than the physical examination maneuvers from which they are derived but may take longer to perform. We recommend a combination of traditional physical examination and sonographic techniques when evaluating for splenomegaly at the bedside. © 2017 by the American Institute of Ultrasound in Medicine.

  1. Establishment of reference intervals of clinical chemistry analytes for the adult population in Saudi Arabia: a study conducted as a part of the IFCC global study on reference values.

    PubMed

    Borai, Anwar; Ichihara, Kiyoshi; Al Masaud, Abdulaziz; Tamimi, Waleed; Bahijri, Suhad; Armbuster, David; Bawazeer, Ali; Nawajha, Mustafa; Otaibi, Nawaf; Khalil, Haitham; Kawano, Reo; Kaddam, Ibrahim; Abdelaal, Mohamed

    2016-05-01

    This study is a part of the IFCC-global study to derive reference intervals (RIs) for 28 chemistry analytes in Saudis. Healthy individuals (n=826) aged ≥18 years were recruited using the global study protocol. All specimens were measured using an Architect analyzer. RIs were derived by both parametric and non-parametric methods for comparative purpose. The need for secondary exclusion of reference values based on latent abnormal values exclusion (LAVE) method was examined. The magnitude of variation attributable to gender, ages and regions was calculated by the standard deviation ratio (SDR). Sources of variations: age, BMI, physical exercise and smoking levels were investigated by using the multiple regression analysis. SDRs for gender, age and regional differences were significant for 14, 8 and 2 analytes, respectively. BMI-related changes in test results were noted conspicuously for CRP. For some metabolic related parameters the ranges of RIs by non-parametric method were wider than by the parametric method and RIs derived using the LAVE method were significantly different than those without it. RIs were derived with and without gender partition (BMI, drugs and supplements were considered). RIs applicable to Saudis were established for the majority of chemistry analytes, whereas gender, regional and age RI partitioning was required for some analytes. The elevated upper limits of metabolic analytes reflects the existence of high prevalence of metabolic syndrome in Saudi population.

  2. Recommendation for the review of biological reference intervals in medical laboratories.

    PubMed

    Henny, Joseph; Vassault, Anne; Boursier, Guilaine; Vukasovic, Ines; Mesko Brguljan, Pika; Lohmander, Maria; Ghita, Irina; Andreu, Francisco A Bernabeu; Kroupis, Christos; Sprongl, Ludek; Thelen, Marc H M; Vanstapel, Florent J L A; Vodnik, Tatjana; Huisman, Willem; Vaubourdolle, Michel

    2016-12-01

    This document is based on the original recommendation of the Expert Panel on the Theory of Reference Values of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), updated guidelines were recently published under the auspices of the IFCC and the Clinical and Laboratory Standards Institute (CLSI). This document summarizes proposals for recommendations on: (i) The terminology, which is often confusing, noticeably concerning the terms of reference limits and decision limits. (ii) The method for the determination of reference limits according to the original procedure and the conditions, which should be used. (iii) A simple procedure allowing the medical laboratories to fulfill the requirements of the regulation and standards. The updated document proposes to verify that published reference limits are applicable to the laboratory involved. Finally, the strengths and limits of the revised recommendations (especially the selection of the reference population, the maintenance of the analytical quality, the choice of the statistical method used…) will be briefly discussed.

  3. Implementing NICE Guidelines on Recall Intervals into General Practice.

    PubMed

    Akram, Sarah; D’Cruz, Len

    2010-09-01

    The NICE guidelines require practitioners to ensure that each patient has a specific recall interval based on an oral health needs assessment. There appears to be a hesitancy in the profession to move away from the ‘six-month recall’. In England and Wales, Primary Care Organizations (PCOs) monitor activity using quantitative data. One particular metric measures how many patients are seen by the practice within 3 months and also between 3 and 9 months from their last course of treatment. The purpose of this paper is to introduce a quick reference chart based on the NICE guidelines which, when used in combination with clinical judgement, can aid the clinician in selecting a tailored recall interval. This paper discusses the purpose and benefits for using the guidelines in relation to NHS contractual obligations.

  4. Acoustical numerology and lucky equal temperaments

    NASA Astrophysics Data System (ADS)

    Hall, Donald E.

    1988-04-01

    Equally tempered musical scales with N steps per octave are known to work especially well in approximating justly tuned intervals for such values as N=12, 19, 31, and 53. A quantitative measure of the closeness of such fits is suggested, in terms of the probabilities of coming as close to randomly chosen intervals as to the justly tuned targets. When two or more harmonic intervals are considered simultaneously, this involves a Monte Carlo evaluation of the probabilities. The results can be used to gauge how much advantage the special values of N mentioned above have over others. This article presents the rationale and method of computation, together with illustrative results in a few of the most interesting cases. References are provided to help relate these results to earlier works by music theorists.

  5. Reference Values of 14 Serum Trace Elements for Pregnant Chinese Women: A Cross-Sectional Study in the China Nutrition and Health Survey 2010-2012.

    PubMed

    Liu, Xiaobing; Zhang, Yu; Piao, Jianhua; Mao, Deqian; Li, Yajie; Li, Weidong; Yang, Lichen; Yang, Xiaoguang

    2017-03-21

    The development of reference values of trace elements is recognized as a fundamental prerequisite for the assessment of trace element nutritional status and health risks. In this study, a total of 1400 pregnant women aged 27.0 ± 4.5 years were randomly selected from the China Nutrition and Health Survey 2010-2012 (CNHS 2010-2012). The concentrations of 14 serum trace elements were determined by high-resolution inductively coupled plasma mass spectrometry. Reference values were calculated covering the central 95% reference intervals (P2.5-P97.5) after excluding outliers by Dixon's test. The overall reference values of serum trace elements were 131.5 (55.8-265.0 μg/dL for iron (Fe), 195.5 (107.0-362.4) μg/dL for copper (Cu), 74.0 (51.8-111.3) μg/dL for zinc (Zn), 22.3 (14.0-62.0) μg/dL for rubidium (Rb), 72.2 (39.9-111.6) μg/L for selenium (Se), 45.9 (23.8-104.3) μg/L for strontium (Sr), 1.8 (1.2-3.6) μg/L for molybdenum (Mo), 2.4 (1.2-8.4) μg/L for manganese (Mn), 1.9 (0.6-9.0) ng/L for lead (Pb), 1.1 (0.3-5.6) ng/L for arsenic (As), 835.6 (219.8-4287.7) ng/L for chromium (Cr), 337.9 (57.0-1130.0) ng/L for cobalt (Co), 193.2 (23.6-2323.1) ng/L for vanadium (V), and 133.7 (72.1-595.1) ng/L for cadmium (Cd). Furthermore, some significant differences in serum trace element reference values were observed between different groupings of age intervals, residences, anthropometric status, and duration of pregnancy. We found that serum Fe, Zn, and Se concentrations significantly decreased, whereas serum Cu, Sr, and Co concentrations elevated progressively compared with reference values of 14 serum trace elements in pregnant Chinese women. The reference values of serum trace elements established could play a key role in the following nutritional status and health risk assessment.

  6. Lipid Panel Reference Intervals for Amazon Parrots (Amazona species).

    PubMed

    Ravich, Michelle; Cray, Carolyn; Hess, Laurie; Arheart, Kristopher L

    2014-09-01

    The lipoprotein panel is a useful diagnostic tool that allows clinicians to evaluate blood lipoprotein fractions. It is a standard diagnostic test in human medicine but is poorly understood in avian medicine. Amazon parrots (Amazona species) are popular pets that frequently lead a sedentary lifestyle and are customarily fed high-fat diets. Similar to people with comparable diets and lifestyles, Amazon parrots are prone to obesity and atherosclerosis. In human medicine, these conditions are typically correlated with abnormalities in the lipoprotein panel. To establish reference intervals for the lipoprotein panel in Amazon parrots, plasma samples from 31 captive Amazon parrots were analyzed for concentrations of cholesterol, triglycerides, high-density lipoprotein (HDL), low-density lipoprotein (LDL), and very low-density lipoprotein (VLDL). The data were also grouped according to sex, diet, body condition score, and age. Aside from HDL levels, which were significantly different between male and female parrots, no intergroup differences were found for any of the lipoprotein fractions.

  7. Prepregnancy obesity and complement system activation in early pregnancy and the subsequent development of preeclampsia.

    PubMed

    Lynch, Anne M; Eckel, Robert H; Murphy, James R; Gibbs, Ronald S; West, Nancy A; Giclas, Patricia C; Salmon, Jane E; Holers, V Michael

    2012-05-01

    We hypothesized that women who are obese before they become pregnant and also have elevations of complement Bb and C3a in the top quartile in early pregnancy would have the highest risk of preeclampsia compared with a referent group of women who were not obese and had levels of complement less than the top quartile. This was a prospective study of 1013 women recruited at less than 20 weeks' gestation. An EDTA-plasma sample was obtained, and complement fragments were measured using enzyme-linked immunosorbent assays. The data were analyzed using univariable and multivariable logistic regression analysis. Women who were obese with levels of Bb or C3a in the top quartile were 10.0 (95% confidence interval, 3.3-30) and 8.8 (95% confidence interval, 3-24) times, respectively, more likely to develop preeclampsia compared with the referent group. We demonstrate a combined impact of obesity and elevated complement on the development of preeclampsia. Copyright © 2012. Published by Mosby, Inc.

  8. IFCC approved HPLC reference measurement procedure for the alcohol consumption biomarker carbohydrate-deficient transferrin (CDT): Its validation and use.

    PubMed

    Schellenberg, François; Wielders, Jos; Anton, Raymond; Bianchi, Vincenza; Deenmamode, Jean; Weykamp, Cas; Whitfield, John; Jeppsson, Jan-Olof; Helander, Anders

    2017-02-01

    Carbohydrate-deficient transferrin (CDT) is used as a biomarker of sustained high alcohol consumption. The currently available measurement procedures for CDT are based on various analytical techniques (HPLC, capillary electrophoresis, nephelometry), some differing in the definition of the analyte and using different reference intervals and cut-off values. The Working Group on Standardization of CDT (WG-CDT), initiated by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), has validated an HPLC candidate reference measurement procedure (cRMP) for CDT (% disialotransferrin to total transferrin based on peak areas), demonstrating that it is suitable as a reference measurement procedure (RMP) for CDT. Presented is a detailed description of the cRMP and its calibration. Practical aspects on how to treat genetic variant and so-called di-tri bridge samples are described. Results of method performance characteristics, as demanded by ISO 15189 and ISO 15193, are given, as well as the reference interval and measurement uncertainty and how to deal with that in routine use. The correlation of the cRMP with commercial CDT procedures and the performance of the cRMP in a network of laboratories are also presented. The performance of the CDT cRMP in combination with previously developed commutable calibrators allows for standardization of the currently available commercial measurement procedures for CDT. The cRMP has recently been approved by the IFCC and will be from now on be known as the IFCC-RMP for CDT, while CDT results standardized according to this RMP should be indicated as CDT IFCC . Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Citations to Web pages in scientific articles: the permanence of archived references.

    PubMed

    Thorp, Andrea W; Schriger, David L

    2011-02-01

    We validate the use of archiving Internet references by comparing the accessibility of published uniform resource locators (URLs) with corresponding archived URLs over time. We scanned the "Articles in Press" section in Annals of Emergency Medicine from March 2009 through June 2010 for Internet references in research articles. If an Internet reference produced the authors' expected content, the Web page was archived with WebCite (http://www.webcitation.org). Because the archived Web page does not change, we compared it with the original URL to determine whether the original Web page had changed. We attempted to access each original URL and archived Web site URL at 3-month intervals from the time of online publication during an 18-month study period. Once a URL no longer existed or failed to contain the original authors' expected content, it was excluded from further study. The number of original URLs and archived URLs that remained accessible over time was totaled and compared. A total of 121 articles were reviewed and 144 Internet references were found within 55 articles. Of the original URLs, 15% (21/144; 95% confidence interval [CI] 9% to 21%) were inaccessible at publication. During the 18-month observation period, there was no loss of archived URLs (apart from the 4% [5/123; 95% CI 2% to 9%] that could not be archived), whereas 35% (49/139) of the original URLs were lost (46% loss; 95% CI 33% to 61% by the Kaplan-Meier method; difference between curves P<.0001, log rank test). Archiving a referenced Web page at publication can help preserve the authors' expected information. Copyright © 2010 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.

  10. [Evolution of the bibliometric indicators of production and consumption of Archivos de Bronchopneumología in the last 20 years].

    PubMed

    García Río, F; Dorgham, A; Serrano, S; Terreros Caro, J G; Alvarez-Sala, R; Prados, C; Alvarez-Sala, J L; Villamor, J

    1997-01-01

    The aim of this study was to evaluate the evolution of bibliometric indicators for authorship and citation of ARCHIVOS DE BRONCONEUMOLOGIA over the past 20 years. At least 16 articles reporting new research or case reports were analyzed for every other year from 1976 to 1996. The following data were collected for each article: type of document, number of authors and their place of work and specialty, time interval between acceptance and publication, and references (including number, types, language, journal name and year of publication). The number of authors per article (collaboration index) averaged around five and has not varied significantly over the 20 years studied. Pulmonologists predominated among the authors, accounting for about 60% of the total, and most contributions came from a few provinces, mainly Barcelona and Madrid. The interval between reception and publication has gradually increased over the 20 years under review, coming to stand around 9.9 +/- 1.6 months in 1996. Most references (over 80%) cite journals and the proportion of references to books has decreased in recent years (from 12.3% in 1976 to 3.5% in 1996). The journal's index of isolation has increased (from 6.2 to 12.1%), as has the index of self-citation (from 0.4 to 6.2%). Although most cited works are in English (over 80%), the proportion of Spanish-language references increased (from 6.2 to 12.1%). In conclusion, maintenance of the number of collaborating authors, the predominance of journals and English-language sources among references are the main traits that characterize the bibliometric indicators for authorship and citation in ARCHIVOS DE BRONCONEUMOLOGIA.

  11. The theory of reference values: an unfinished symphony.

    PubMed

    Siest, Gerard; Henny, Joseph; Gräsbeck, Ralph; Wilding, Peter; Petitclerc, Claude; Queraltó, Josep M; Hyltoft Petersen, Peter

    2013-01-01

    The history of the theory of reference values can be written as an unfinished symphony. The first movement, allegro con fuoco, played from 1960 to 1980: a mix of themes devoted to the study of biological variability (intra-, inter-individual, short- and long-term), preanalytical conditions, standardization of analytical methods, quality control, statistical tools for deriving reference limits, all of them complex variations developed on a central melody: the new concept of reference values that would replace the notion of normality whose definition was unclear. Additional contributions (multivariate reference values, use of reference limits from broad sets of patient data, drug interferences) conclude the movement on the variability of laboratory tests. The second movement, adagio, from 1980 to 2000, slowly develops and implements initial works. International and national recommendations were published by the IFCC-LM (International Federation of Clinical Chemistry and Laboratory Medicine) and scientific societies [French (SFBC), Spanish (SEQC), Scandinavian societies…]. Reference values are now topics of many textbooks and of several congresses, workshops, and round tables that are organized all over the world. Nowadays, reference values are part of current practice in all clinical laboratories, but not without difficulties, particularly for some laboratories to produce their own reference values and the unsuitability of the concept with respect to new technologies such as HPLC, GCMS, and PCR assays. Clinicians through consensus groups and practice guidelines have introduced their own tools, the decision limits, likelihood ratios and Reference Change Value (RCV), creating confusion among laboratorians and clinicians in substituting reference values and decision limits in laboratory reports. The rapid development of personalized medicine will eventually call for the use of individual reference values. The beginning of the second millennium is played allegro ma non-troppo from 2000 to 2012: the theory of reference values is back into fashion. The need to revise the concept is emerging. The manufacturers make a friendly pressure to facilitate the integration of Reference Intervals (RIs) in their technical documentation. Laboratorians are anxiously awaiting the solutions for what to do. The IFCC-LM creates Reference Intervals and Decision Limits Committee (C-RIDL) in 2005. Simultaneously, a joint working group IFCC-CLSI is created on the same topic. In 2008 the initial recommendations of IFCC-LM are revised and new guidelines are published by the Clinical and Laboratory Standards Institute (CLSI C28-A3). Fundamentals of the theory of reference values are not changed, but new avenues are explored: RIs transference, multicenter reference intervals, and a robust method for deriving RIs from small number of subjects. Concomitantly, other statistical methods are published such as bootstraps calculation and partitioning procedures. An alternative to recruiting healthy subjects proposes the use of biobanks conditional to the availability of controlled preanalytical conditions and of bioclinical data. The scope is also widening to include veterinary biology! During the early 2000s, several groups proposed the concept of 'Universal RIs' or 'Global RIs'. Still controversial, their applications await further investigations. The fourth movement, finale: beyond the methodological issues (statistical and analytical essentially), important questions remain unanswered. Do RIs intervene appropriately in medical decision-making? Are RIs really useful to the clinicians? Are evidence-based decision limits more appropriate? It should be appreciated that many laboratory tests represent a continuum that weakens the relevance of RIs. In addition, the boundaries between healthy and pathological states are shady areas influenced by many biological factors. In such a case the use of a single threshold is questionable. Wherever it will apply, individual reference values and reference change values have their place. A variation on an old theme! It is strange that in the period of personalized medicine (that is more stratified medicine), the concept of reference values which is based on stratification of homogeneous subgroups of healthy people could not be discussed and developed in conjunction with the stratification of sick patients. That is our message for the celebration of the 50th anniversary of Clinical Chemistry and Laboratory Medicine. Prospects are broad, enthusiasm is not lacking: much remains to be done, good luck for the new generations!

  12. Reference Intervals for Preprandial and Postprandial Serum Bile Acid in Adult Rhesus Macaques (Macaca mulatta)

    PubMed Central

    Lemoy, Marie-Josee MF; Westworth, Diccon R; Ardeshir, Amir; Tarara, Ross P

    2013-01-01

    The purpose of this study was to determine the 12-h fasting preprandial and 2-h postprandial serum bile acid concentration (SBAC) reference intervals for healthy, adult rhesus macaques (Macaca mulatta). We hypothesized that the mean 2-h postprandial SBAC would be significantly higher than the mean preprandial SBAC. We included 40 (24 male, 16 female) macaques after confirming that their health records, physical examinations, CBC, serum chemistry panels, and urinalyses were all within normal limits. In addition, hepatitis A titers were determined, an ultrasound examination of the liver was performed, and two 16-gauge ultrasound guided percutaneous liver biopsies were collected and submitted for histopathology. Macaques were confirmed healthy according to hepatitis A screens and sonographic and histologic evaluation of hepatic tissue. Within 2 wk of the screening procedures, preprandial and postprandial SBACs were measured. Preprandial SBAC (mean ± 1 SD) was 11.1 ± 1.9 µmol/L and postprandial SBAC was 19.7 ± 8.0 µmol/L, which was significantly higher than the preprandial value. Sex and hepatitis titers did not significantly influence preprandial and postprandial SBAC. The current study indicates that the SBAC reference values for rhesus macaques are higher than those reported for humans and companion animals. PMID:23849441

  13. Reference intervals for preprandial and postprandial serum bile acid in adult rhesus macaques (Macaca mulatta).

    PubMed

    Lemoy, Marie-Josee M F; Westworth, Diccon R; Ardeshir, Amir; Tarara, Ross P

    2013-07-01

    The purpose of this study was to determine the 12-h fasting preprandial and 2-h postprandial serum bile acid concentration (SBAC) reference intervals for healthy, adult rhesus macaques (Macaca mulatta). We hypothesized that the mean 2-h postprandial SBAC would be significantly higher than the mean preprandial SBAC. We included 40 (24 male, 16 female) macaques after confirming that their health records, physical examinations, CBC, serum chemistry panels, and urinalyses were all within normal limits. In addition, hepatitis A titers were determined, an ultrasound examination of the liver was performed, and two 16-gauge ultrasound guided percutaneous liver biopsies were collected and submitted for histopathology. Macaques were confirmed healthy according to hepatitis A screens and sonographic and histologic evaluation of hepatic tissue. Within 2 wk of the screening procedures, preprandial and postprandial SBACs were measured. Preprandial SBAC (mean ± 1 SD) was 11.1 ± 1.9 μmol/L and postprandial SBAC was 19.7 ± 8.0 μmol/L, which was significantly higher than the preprandial value. Sex and hepatitis titers did not significantly influence preprandial and postprandial SBAC. The current study indicates that the SBAC reference values for rhesus macaques are higher than those reported for humans and companion animals.

  14. Age and Gender-Specific Reference Intervals for ProGRP in Healthy Chinese Han Ethnic Adults using the Roche Cobas Immunoassay.

    PubMed

    Zhu, Yanhui; Yuan, Yulin; Yang, Xiafang; Lu, Qiuwei; Lu, Xiaoxu; Huang, Huayi

    2018-06-01

    Pro-gastrin-releasing peptide (ProGRP) is a kind of tumor marker applied more and more commonly in recent years. This study was aimed at determining the age and gender-specific reference intervals (RIs) for ProGRP in healthy Han ethnic adults from Guangxi, China. A total of 2,045 apparently healthy males and 1,740 apparently healthy females aged from 21 to 90 years were included in this study. The serum ProGRP values were determined by electrochemiluminescence immunoassay (ECLIA). The one-sided upper 95th percentile of ProGRP concentrations were used to define the RIs. The reference limits in different age groups (21 - 40, 41 - 50, 51 - 60, 61 - 70, and > 70 years) were 37.3, 39.7, 45.7, 47.3, and 61.3 pg/mL for males, and 36.3, 38.1, 42.7, 53.5, and 60.1 pg/mL for females, respectively. There was no significant difference in the levels of ProGRP between males and females. The serum ProGRP levels were positively correlated with age. We established the age and gender-specific RIs for ProGRP in the adults from Guangxi, China. It will be valuable for future clinical and laboratory studies.

  15. Three-dimensional image display system using stereogram and holographic optical memory techniques

    NASA Astrophysics Data System (ADS)

    Kim, Cheol S.; Kim, Jung G.; Shin, Chang-Mok; Kim, Soo-Joong

    2001-09-01

    In this paper, we implemented a three dimensional image display system using stereogram and holographic optical memory techniques which can store many images and reconstruct them automatically. In this system, to store and reconstruct stereo images, incident angle of reference beam must be controlled in real time, so we used BPH (binary phase hologram) and LCD (liquid crystal display) for controlling reference beam. And input images are represented on the LCD without polarizer/analyzer for maintaining uniform beam intensities regardless of the brightness of input images. The input images and BPHs are edited using application software with having the same recording scheduled time interval in storing. The reconstructed stereo images are acquired by capturing the output images with CCD camera at the behind of the analyzer which transforms phase information into brightness information of images. The reference beams are acquired by Fourier transform of BPH which designed with SA (simulated annealing) algorithm, and represented on the LCD with the 0.05 seconds time interval using application software for reconstructing the stereo images. In output plane, we used a LCD shutter that is synchronized to a monitor that displays alternate left and right eye images for depth perception. We demonstrated optical experiment which store and reconstruct four stereo images in BaTiO3 repeatedly using holographic optical memory techniques.

  16. Evolution of motion uncertainty in rectal cancer: implications for adaptive radiotherapy

    NASA Astrophysics Data System (ADS)

    Kleijnen, Jean-Paul J. E.; van Asselen, Bram; Burbach, Johannes P. M.; Intven, Martijn; Philippens, Marielle E. P.; Reerink, Onne; Lagendijk, Jan J. W.; Raaymakers, Bas W.

    2016-01-01

    Reduction of motion uncertainty by applying adaptive radiotherapy strategies depends largely on the temporal behavior of this motion. To fully optimize adaptive strategies, insight into target motion is needed. The purpose of this study was to analyze stability and evolution in time of motion uncertainty of both the gross tumor volume (GTV) and clinical target volume (CTV) for patients with rectal cancer. We scanned 16 patients daily during one week, on a 1.5 T MRI scanner in treatment position, prior to each radiotherapy fraction. Single slice sagittal cine MRIs were made at the beginning, middle, and end of each scan session, for one minute at 2 Hz temporal resolution. GTV and CTV motion were determined by registering a delineated reference frame to time-points later in time. The 95th percentile of observed motion (dist95%) was taken as a measure of motion. The stability of motion in time was evaluated within each cine-MRI separately. The evolution of motion was investigated between the reference frame and the cine-MRIs of a single scan session and between the reference frame and the cine-MRIs of several days later in the course of treatment. This observed motion was then converted into a PTV-margin estimate. Within a one minute cine-MRI scan, motion was found to be stable and small. Independent of the time-point within the scan session, the average dist95% remains below 3.6 mm and 2.3 mm for CTV and GTV, respectively 90% of the time. We found similar motion over time intervals from 18 min to 4 days. When reducing the time interval from 18 min to 1 min, a large reduction in motion uncertainty is observed. A reduction in motion uncertainty, and thus the PTV-margin estimate, of 71% and 75% for CTV and tumor was observed, respectively. Time intervals of 15 and 30 s yield no further reduction in motion uncertainty compared to a 1 min time interval.

  17. A Numerical-Analytical Approach to Modeling the Axial Rotation of the Earth

    NASA Astrophysics Data System (ADS)

    Markov, Yu. G.; Perepelkin, V. V.; Rykhlova, L. V.; Filippova, A. S.

    2018-04-01

    A model for the non-uniform axial rotation of the Earth is studied using a celestial-mechanical approach and numerical simulations. The application of an approximate model containing a small number of parameters to predict variations of the axial rotation velocity of the Earth over short time intervals is justified. This approximate model is obtained by averaging variable parameters that are subject to small variations due to non-stationarity of the perturbing factors. The model is verified and compared with predictions over a long time interval published by the International Earth Rotation and Reference Systems Service (IERS).

  18. 42 CFR 493.1253 - Standard: Establishment and verification of performance specifications.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Establishment and verification of..., DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS... of test results for the test system. (vi) Reference intervals (normal values). (vii) Any other...

  19. The usefulness of rapid point-of-care creatinine testing for the prevention of contrast-induced nephropathy in the emergency department.

    PubMed

    You, Je Sung; Chung, Yong Eun; Park, Jong Woo; Lee, Woonhyoung; Lee, Hye-Jeong; Chung, Tae Nyoung; Chung, Sung Phil; Park, Incheol; Kim, Seungho

    2013-07-01

    Renal dysfunction is the most important factor to consider when predicting a patient's risk of developing contrast-induced nephropathy (CIN). Measurement of creatinine (Cr) via rapid point-of-care blood urea nitrogen/creatinine testing (POCT-BUN/Cr) to determine CIN risk could potentially reduce the time required to achieve an accurate diagnosis and to initiate and complete treatment in the emergency department (ED). The aim of our study was to compare the results of POCT-BUN/Cr and reference laboratory tests for BUN and serum Cr. A retrospective analysis of suspected stroke patients who presented between November 2009 and November 2010, and had BUN and Cr levels measured by POCT-BUN/Cr, and the reference laboratory tests performed with the blood sample which was transferred to the central laboratory by an air-shoot system. Two assays were conducted on the whole blood (POCT) and serum (reference) by trained technicians. The time interval from arrival at the ED to reporting of the results was assessed for both assays via a computerised physician order entry system. The mean standard deviation (SD) interval from arrival at the ED to reporting of the results was 11.4 (4.9) min for POCT-BUN/Cr and 46.8 (38.5) min for the serum reference laboratory tests (p<0.001). Intra-class correlation coefficient (ICC) analysis demonstrated a high level of agreement (the consistency agreement) between POCT and the serum reference tests for both BUN (ICC=0.914) and Cr (ICC=0.980). This study suggests that POCT-BUN/Cr results correlate well with those of serum reference tests in terms of BUN and Cr levels and, in turn, predicting CIN. POCT-BUN/Cr is easily performed with a rapid turnaround time, suggesting its use in the ED may have substantial clinical benefit.

  20. Short-term memory in zebrafish (Danio rerio).

    PubMed

    Jia, Jason; Fernandes, Yohaan; Gerlai, Robert

    2014-08-15

    Learning and memory represent perhaps the most complex behavioral phenomena. Although their underlying mechanisms have been extensively analyzed, only a fraction of the potential molecular components have been identified. The zebrafish has been proposed as a screening tool with which mechanisms of complex brain functions may be systematically uncovered. However, as a relative newcomer in behavioral neuroscience, the zebrafish has not been well characterized for its cognitive and mnemonic features, thus learning and/or memory screens with adults have not been feasible. Here we study short-term memory of adult zebrafish. We show animated images of conspecifics (the stimulus) to the experimental subject during 1 min intervals on ten occasions separated by different (2, 4, 8 or 16 min long) inter-stimulus intervals (ISI), a between subject experimental design. We quantify the distance of the subject from the image presentation screen during each stimulus presentation interval, during each of the 1-min post-stimulus intervals immediately following the stimulus presentations and during each of the 1-min intervals furthest away from the last stimulus presentation interval and just before the next interval (pre-stimulus interval), respectively. Our results demonstrate significant retention of short-term memory even in the longest ISI group but suggest no acquisition of reference memory. Because in the employed paradigm both stimulus presentation and behavioral response quantification is computer automated, we argue that high-throughput screening for drugs or mutations that alter short-term memory performance of adult zebrafish is now becoming feasible. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Interpregnancy interval and risk of autistic disorder.

    PubMed

    Gunnes, Nina; Surén, Pål; Bresnahan, Michaeline; Hornig, Mady; Lie, Kari Kveim; Lipkin, W Ian; Magnus, Per; Nilsen, Roy Miodini; Reichborn-Kjennerud, Ted; Schjølberg, Synnve; Susser, Ezra Saul; Øyen, Anne-Siri; Stoltenberg, Camilla

    2013-11-01

    A recent California study reported increased risk of autistic disorder in children conceived within a year after the birth of a sibling. We assessed the association between interpregnancy interval and risk of autistic disorder using nationwide registry data on pairs of singleton full siblings born in Norway. We defined interpregnancy interval as the time from birth of the first-born child to conception of the second-born child in a sibship. The outcome of interest was autistic disorder in the second-born child. Analyses were restricted to sibships in which the second-born child was born in 1990-2004. Odds ratios (ORs) were estimated by fitting ordinary logistic models and logistic generalized additive models. The study sample included 223,476 singleton full-sibling pairs. In sibships with interpregnancy intervals <9 months, 0.25% of the second-born children had autistic disorder, compared with 0.13% in the reference category (≥ 36 months). For interpregnancy intervals shorter than 9 months, the adjusted OR of autistic disorder in the second-born child was 2.18 (95% confidence interval 1.42-3.26). The risk of autistic disorder in the second-born child was also increased for interpregnancy intervals of 9-11 months in the adjusted analysis (OR = 1.71 [95% CI = 1.07-2.64]). Consistent with a previous report from California, interpregnancy intervals shorter than 1 year were associated with increased risk of autistic disorder in the second-born child. A possible explanation is depletion of micronutrients in mothers with closely spaced pregnancies.

  2. The effects of context and musical training on auditory temporal-interval discrimination.

    PubMed

    Banai, Karen; Fisher, Shirley; Ganot, Ron

    2012-02-01

    Non sensory factors such as stimulus context and musical experience are known to influence auditory frequency discrimination, but whether the context effect extends to auditory temporal processing remains unknown. Whether individual experiences such as musical training alter the context effect is also unknown. The goal of the present study was therefore to investigate the effects of stimulus context and musical experience on auditory temporal-interval discrimination. In experiment 1, temporal-interval discrimination was compared between fixed context conditions in which a single base temporal interval was presented repeatedly across all trials and variable context conditions in which one of two base intervals was randomly presented on each trial. Discrimination was significantly better in the fixed than in the variable context conditions. In experiment 2 temporal discrimination thresholds of musicians and non-musicians were compared across 3 conditions: a fixed context condition in which the target interval was presented repeatedly across trials, and two variable context conditions differing in the frequencies used for the tones marking the temporal intervals. Musicians outperformed non-musicians on all 3 conditions, but the effects of context were similar for the two groups. Overall, it appears that, like frequency discrimination, temporal-interval discrimination benefits from having a fixed reference. Musical experience, while improving performance, did not alter the context effect, suggesting that improved discrimination skills among musicians are probably not an outcome of more sensitive contextual facilitation or predictive coding mechanisms. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Estimation of aquifer scale proportion using equal area grids: assessment of regional scale groundwater quality

    USGS Publications Warehouse

    Belitz, Kenneth; Jurgens, Bryant C.; Landon, Matthew K.; Fram, Miranda S.; Johnson, Tyler D.

    2010-01-01

    The proportion of an aquifer with constituent concentrations above a specified threshold (high concentrations) is taken as a nondimensional measure of regional scale water quality. If computed on the basis of area, it can be referred to as the aquifer scale proportion. A spatially unbiased estimate of aquifer scale proportion and a confidence interval for that estimate are obtained through the use of equal area grids and the binomial distribution. Traditionally, the confidence interval for a binomial proportion is computed using either the standard interval or the exact interval. Research from the statistics literature has shown that the standard interval should not be used and that the exact interval is overly conservative. On the basis of coverage probability and interval width, the Jeffreys interval is preferred. If more than one sample per cell is available, cell declustering is used to estimate the aquifer scale proportion, and Kish's design effect may be useful for estimating an effective number of samples. The binomial distribution is also used to quantify the adequacy of a grid with a given number of cells for identifying a small target, defined as a constituent that is present at high concentrations in a small proportion of the aquifer. Case studies illustrate a consistency between approaches that use one well per grid cell and many wells per cell. The methods presented in this paper provide a quantitative basis for designing a sampling program and for utilizing existing data.

  4. Correction Approach for Delta Function Convolution Model Fitting of Fluorescence Decay Data in the Case of a Monoexponential Reference Fluorophore.

    PubMed

    Talbot, Clifford B; Lagarto, João; Warren, Sean; Neil, Mark A A; French, Paul M W; Dunsby, Chris

    2015-09-01

    A correction is proposed to the Delta function convolution method (DFCM) for fitting a multiexponential decay model to time-resolved fluorescence decay data using a monoexponential reference fluorophore. A theoretical analysis of the discretised DFCM multiexponential decay function shows the presence an extra exponential decay term with the same lifetime as the reference fluorophore that we denote as the residual reference component. This extra decay component arises as a result of the discretised convolution of one of the two terms in the modified model function required by the DFCM. The effect of the residual reference component becomes more pronounced when the fluorescence lifetime of the reference is longer than all of the individual components of the specimen under inspection and when the temporal sampling interval is not negligible compared to the quantity (τR (-1) - τ(-1))(-1), where τR and τ are the fluorescence lifetimes of the reference and the specimen respectively. It is shown that the unwanted residual reference component results in systematic errors when fitting simulated data and that these errors are not present when the proposed correction is applied. The correction is also verified using real data obtained from experiment.

  5. Perspective: The case for an evidence-based reference interval for serum magnesium: The time has come

    USDA-ARS?s Scientific Manuscript database

    The 2015 Dietary Guidelines Advisory Committee indicated magnesium was a shortfall nutrient that was underconsumed relative to the Estimated Average Requirement (EAR) for many Americans. Approximately 50% of Americans consume less than the EAR for magnesium, and some age groups consume substantially...

  6. Fault tolerant control based on interval type-2 fuzzy sliding mode controller for coaxial trirotor aircraft.

    PubMed

    Zeghlache, Samir; Kara, Kamel; Saigaa, Djamel

    2015-11-01

    In this paper, a robust controller for a Six Degrees of Freedom (6 DOF) coaxial trirotor helicopter control is proposed in presence of defects in the system. A control strategy based on the coupling of the interval type-2 fuzzy logic control and sliding mode control technique are used to design a controller. The main purpose of this work is to eliminate the chattering phenomenon and guaranteeing the stability and the robustness of the system. In order to achieve this goal, interval type-2 fuzzy logic control has been used to generate the discontinuous control signal. The simulation results have shown that the proposed control strategy can greatly alleviate the chattering effect, and perform good reference tracking in presence of defects in the system. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  7. Appendectomy in patients with human immunodeficiency virus: Not as bad as we once thought.

    PubMed

    Smith, Michael C; Chung, Paul J; Constable, Yohannes C; Boylan, Matthew R; Alfonso, Antonio E; Sugiyama, Gainosuke

    2017-04-01

    The number of patients living with human immunodeficiency virus and acquired immunodeficiency syndrome is growing due to advances in antiretroviral therapy. Existing literature on appendectomy within this patient population has been limited by small sample sizes. Therefore, we used a large, multiyear, nationwide database to study this topic comprehensively. Using the Nationwide Inpatient Sample, we identified 338,805 patients between 2005 and 2012 who underwent laparoscopic or open appendectomy for acute appendicitis. Interval appendectomies were excluded. We used multivariable adjusted regression models to test differences between patients with human immunodeficiency virus without acquired immunodeficiency syndrome and a reference group, as well as human immunodeficiency virus with acquired immunodeficiency syndrome and a reference group, with regard to duration of stay, hospital charges, in-hospital complications, and in-hospital mortality. Models were adjusted for patient age, sex, race, insurance, socioeconomic status, Elixhauser comorbidity score, and appendix perforation. There were 1,291 (0.38%) patients with human immunodeficiency virus, among which 497 (0.15%) patients had acquired immunodeficiency syndrome. In regression analysis, human immunodeficiency virus alone was not associated with adverse outcomes, while acquired immunodeficiency syndrome alone was associated with longer duration of stay (incidence rate ratio 1.40 [1.37-1.57 95% confidence interval], P < .0001), increased total charges (exponentiated coefficient 1.16 [1.10-1.23 95% confidence interval], P < .0001), and increased risk of postoperative infection (odds ratio 2.12 [1.44-3.13 95% confidence interval], P = .0002). Patients with acquired immunodeficiency syndrome who undergo appendectomy for acute appendicitis are subject to longer and more expensive hospital admissions and have greater rates of postoperative infections while patients with human immunodeficiency virus alone are not at risk for adverse outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Effect of interpregnancy interval on adverse pregnancy outcomes in northern Tanzania: a registry-based retrospective cohort study.

    PubMed

    Mahande, Michael J; Obure, Joseph

    2016-06-07

    Both short and long interpregnancy intervals have been associated with an increased risk of adverse pregnancy outcomes. There is limited information about the impact of interpregnancy interval on pregnancy (IPI) outcomes in Tanzania. The objective of this study was to assess the effect of IPI on adverse pregnancy outcomes. We performed a retrospective cohort study using maternally-linked data from Kilimanjaro Christian Medical Centre (KCMC) birth registry. A total of 17,030 singlet births from women who delivered singleton infant at KCMC from 2000 to 2010 were studied. Women with multi-fetal gestations and those who were referred from rural areas for various medical reasons were excluded. Outcome variables were preterm birth, low birth weight infants and perinatal death. A multiple logistic regression was used to assess the association between IPI and pregnancy outcomes. The median IPI was 36 months. Compared with IPIs of 24-36 months (referent group), short interpregnancy intervals (<24 months) was associated with preterm delivery (OR 1 · 52; 95 % CI 1.31-1.74); low birth weight (OR 1 · 61; 95 % CI 1 · 34-1.72) and perinatal death, (OR 1 · 63; 95 % CI 1.22-1.91). The IPI of 37-59 months or longer were also associated with higher risks of preterm birth and low birth weight, but not with perinatal death. Our study confirmed that both short and long IPI are independent risk factors for adverse pregnancy outcomes. These finding emphasize the importance of providing support for family planning programs which will support optimal IPI and improve pregnancy outcomes.

  9. Bioavailability of oxycodone after administration of a new prolonged-release once-daily tablet formulation in healthy subjects, in comparison to an established twice-daily tablet
.

    PubMed

    Scheidel, Bernhard; Maritz, Martina A; Gschwind, Yves J; Steigerwald, Kerstin; Guth, Volker; Kovacs, Peter; Rey, Helene

    2017-11-01

    To evaluate and to compare the bioavailability, the influence of food intake on the bioavailability, and the safety and tolerability of a newly-developed oxycodone once-daily (OOD) prolonged-release tablet with an established oxycodone twice-daily (OTD) prolonged-release tablet after single-dose administration under fasting or fed conditions as well as after multiple-dose administration. Three single-center, open-label, randomized, balanced, two-treatment, two-period, two-sequence crossover studies were conducted. In each study, 36 healthy volunteers were randomized to receive 10 mg oxycodone daily as OOD (oxycodone HCL 10-mg PR tablets XL (Develco Pharma Schweiz AG, Pratteln, Switzerland); administration of 1 tablet in the morning) or as OTD (reference formulation: oxygesic 5-mg tablets (Mundipharma GmbH, Limburg an der Lahn, Germany); administration of 1 tablet in the morning and 1 tablet in the evening). Tablets were administered once daily or twice daily under fasting conditions (study 1) or under fed conditions (study 2) as well as after multiple-dose administration (study 3). A sufficient number of blood samples were taken for describing plasma profiles and for calculation of pharmacokinetic parameters. Plasma concentrations of oxycodone were determined by LC-MS/MS. Safety and tolerability were monitored and assessed in all three studies. Plasma profiles of OOD reveal sustained concentrations of oxycodone over the complete dosing interval of 24 hours. In comparison to the OTD reference formulation, the OOD test formulation showed a slightly slower increase of concentrations within the absorption phase and similar plasma concentrations at the maximum and at the end of the dosing interval (24 hours). Extent of bioavailability (AUC), maximum plasma concentrations (Cmax), and plasma concentrations at the end of the dosing interval (Cτ,ss,24h) of OOD could be classified as comparable to OTD considering 90% confidence intervals (CIs) and acceptance limits of 80.00 - 125.00%. Bioavailability of OOD was not influenced by concomitant food intake. OOD and OTD were generally well tolerated, a difference between the two products could not be observed. The new 10-mg OOD formulation provides sustained oxycodone plasma concentrations over the dosing interval of 24 hours and is suitable for once-daily administration. Bioavailability of OOD could be classified as comparable to the twice-daily administration of the OTD reference formulation. The new formulation widens and optimizes the range of strong opioid drug products in patient-centered therapy of chronic pain with simplified dosing and better compliance.
.

  10. Sub-Audible Speech Recognition Based upon Electromyographic Signals

    NASA Technical Reports Server (NTRS)

    Jorgensen, Charles C. (Inventor); Agabon, Shane T. (Inventor); Lee, Diana D. (Inventor)

    2012-01-01

    Method and system for processing and identifying a sub-audible signal formed by a source of sub-audible sounds. Sequences of samples of sub-audible sound patterns ("SASPs") for known words/phrases in a selected database are received for overlapping time intervals, and Signal Processing Transforms ("SPTs") are formed for each sample, as part of a matrix of entry values. The matrix is decomposed into contiguous, non-overlapping two-dimensional cells of entries, and neural net analysis is applied to estimate reference sets of weight coefficients that provide sums with optimal matches to reference sets of values. The reference sets of weight coefficients are used to determine a correspondence between a new (unknown) word/phrase and a word/phrase in the database.

  11. Quantitative Assessment of Commutability for Clinical Viral Load Testing Using a Digital PCR-Based Reference Standard

    PubMed Central

    Tang, L.; Sun, Y.; Buelow, D.; Gu, Z.; Caliendo, A. M.; Pounds, S.

    2016-01-01

    Given recent advances in the development of quantitative standards, particularly WHO international standards, efforts to better understand the commutability of reference materials have been made. Existing approaches in evaluating commutability include prediction intervals and correspondence analysis; however, the results obtained from existing approaches may be ambiguous. We have developed a “deviation-from-ideal” (DFI) approach to evaluate commutability of standards and applied it to the assessment of Epstein-Bar virus (EBV) load testing in four quantitative PCR assays, treating digital PCR as a reference assay. We then discuss advantages and limitations of the DFI approach as well as experimental design to best evaluate the commutability of an assay in practice. PMID:27076654

  12. Evaluation of an in-practice wet-chemistry analyzer using canine and feline serum samples.

    PubMed

    Irvine, Katherine L; Burt, Kay; Papasouliotis, Kostas

    2016-01-01

    A wet-chemistry biochemical analyzer was assessed for in-practice veterinary use. Its small size may mean a cost-effective method for low-throughput in-house biochemical analyses for first-opinion practice. The objectives of our study were to determine imprecision, total observed error, and acceptability of the analyzer for measurement of common canine and feline serum analytes, and to compare clinical sample results to those from a commercial reference analyzer. Imprecision was determined by within- and between-run repeatability for canine and feline pooled samples, and manufacturer-supplied quality control material (QCM). Total observed error (TEobs) was determined for pooled samples and QCM. Performance was assessed for canine and feline pooled samples by sigma metric determination. Agreement and errors between the in-practice and reference analyzers were determined for canine and feline clinical samples by Bland-Altman and Deming regression analyses. Within- and between-run precision was high for most analytes, and TEobs(%) was mostly lower than total allowable error. Performance based on sigma metrics was good (σ > 4) for many analytes and marginal (σ > 3) for most of the remainder. Correlation between the analyzers was very high for most canine analytes and high for most feline analytes. Between-analyzer bias was generally attributed to high constant error. The in-practice analyzer showed good overall performance, with only calcium and phosphate analyses identified as significantly problematic. Agreement for most analytes was insufficient for transposition of reference intervals, and we recommend that in-practice-specific reference intervals be established in the laboratory. © 2015 The Author(s).

  13. Hematology and plasma chemistry reference intervals for mature laboratory pine voles (Microtus pinetorum) as determined by using the nonparametric rank percentile method.

    PubMed

    Harvey, Stephen B; Krimer, Paula M; Correa, Maria T; Hanes, Martha A

    2008-07-01

    Plasma biochemical and hematologic values are important parameters for assessing animal health and experimental results. Although normal reference values for many rodent species have been published, there is a dearth of similar information for the genus Microtus. In addition, most studies use a mean and standard deviation to establish reference intervals, but doing so is not the recommendation of the Clinical and Laboratory Standards Institute (formerly the National Committee on Clinical Laboratory Standards) or the International Federation of Clinical Chemistry and Laboratory Medicine. The purpose of this study was to establish normal reference parameters for plasma biochemistry and hematology in mature pine voles (Microtus pinetorum) by using the nonparametric rank percentile method as recommended by the 2 laboratory medicine organizations mentioned. Samples of cardiac blood from a closed colony of pine voles were collected at euthanasia and evaluated under rodent settings on 2 automated hematology analyzers from 2 different manufacturers and on the same type of automated biochemistry analyzer. There were no sex-associated clinically significant differences between the sexes; younger animals had a lower hematocrit, higher mean corpuscular volume, and lower mean corpuscular hemoglobin concentration than did older animals. Only platelet counts differed when comparing hematologic values from different analyzers. Relative to rats and mice, pine voles have a lower mean corpuscular volume and higher red blood cell count, higher blood urea nitrogen, much higher alanine aminotransferase, and lower glucose and phosphorous concentrations. Hematology and plasma biochemical results obtained in this study are considered representative for healthy adult laboratory pine voles under similar environmental conditions.

  14. Effects of Training and Feedback on Accuracy of Predicting Rectosigmoid Neoplastic Lesions and Selection of Surveillance Intervals by Endoscopists Performing Optical Diagnosis of Diminutive Polyps.

    PubMed

    Vleugels, Jasper L A; Dijkgraaf, Marcel G W; Hazewinkel, Yark; Wanders, Linda K; Fockens, Paul; Dekker, Evelien

    2018-05-01

    Real-time differentiation of diminutive polyps (1-5 mm) during endoscopy could replace histopathology analysis. According to guidelines, implementation of optical diagnosis into routine practice would require it to identify rectosigmoid neoplastic lesions with a negative predictive value (NPV) of more than 90%, using histologic findings as a reference, and agreement with histology-based surveillance intervals for more than 90% of cases. We performed a prospective study with 39 endoscopists accredited to perform colonoscopies on participants with positive results from fecal immunochemical tests in the Bowel Cancer Screening Program at 13 centers in the Netherlands. Endoscopists were trained in optical diagnosis using a validated module (Workgroup serrAted polypS and Polyposis). After meeting predefined performance thresholds in the training program, the endoscopists started a 1-year program (continuation phase) in which they performed narrow band imaging analyses during colonoscopies of participants in the screening program and predicted histological findings with confidence levels. The endoscopists were randomly assigned to groups that received feedback or no feedback on the accuracy of their predictions. Primary outcome measures were endoscopists' abilities to identify rectosigmoid neoplastic lesions (using histology as a reference) with NPVs of 90% or more, and selecting surveillance intervals that agreed with those determined by histology for at least 90% of cases. Of 39 endoscopists initially trained, 27 (69%) completed the training program. During the continuation phase, these 27 endoscopists performed 3144 colonoscopies in which 4504 diminutive polyps were removed. The endoscopists identified neoplastic lesions with a pooled NPV of 90.8% (95% confidence interval 88.6-92.6); their proposed surveillance intervals agreed with those determined by histologic analysis for 95.4% of cases (95% confidence interval 94.0-96.6). Findings did not differ between the group that did vs did not receive feedback. Sixteen endoscopists (59%) identified rectosigmoid neoplastic lesions with NPVs greater than 90% and selected surveillance intervals in agreement with those determined from histology for more than 90% of patients. In a prospective study following a validated training module, we found that a selected group of endoscopists identified rectosigmoid neoplastic lesions with pooled NPVs greater than 90% and accurately selected surveillance intervals for more than 90% of patients over the course of 1 year. Providing regular interim feedback on the accuracy of neoplastic lesion prediction and surveillance interval selection did not lead to differences in those endpoints. Monitoring is suggested, as individual performance varied. ClinicalTrials.gov no: NCT02516748; Netherland Trial Register: NTR4635. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  15. PGA/MOEAD: a preference-guided evolutionary algorithm for multi-objective decision-making problems with interval-valued fuzzy preferences

    NASA Astrophysics Data System (ADS)

    Luo, Bin; Lin, Lin; Zhong, ShiSheng

    2018-02-01

    In this research, we propose a preference-guided optimisation algorithm for multi-criteria decision-making (MCDM) problems with interval-valued fuzzy preferences. The interval-valued fuzzy preferences are decomposed into a series of precise and evenly distributed preference-vectors (reference directions) regarding the objectives to be optimised on the basis of uniform design strategy firstly. Then the preference information is further incorporated into the preference-vectors based on the boundary intersection approach, meanwhile, the MCDM problem with interval-valued fuzzy preferences is reformulated into a series of single-objective optimisation sub-problems (each sub-problem corresponds to a decomposed preference-vector). Finally, a preference-guided optimisation algorithm based on MOEA/D (multi-objective evolutionary algorithm based on decomposition) is proposed to solve the sub-problems in a single run. The proposed algorithm incorporates the preference-vectors within the optimisation process for guiding the search procedure towards a more promising subset of the efficient solutions matching the interval-valued fuzzy preferences. In particular, lots of test instances and an engineering application are employed to validate the performance of the proposed algorithm, and the results demonstrate the effectiveness and feasibility of the algorithm.

  16. Ventricular repolarization alterations in women with angina pectoris and suspected coronary microvascular dysfunction.

    PubMed

    Dose, Nynne; Michelsen, Marie Mide; Mygind, Naja Dam; Pena, Adam; Ellervik, Christina; Hansen, Peter R; Kanters, Jørgen K; Prescott, Eva; Kastrup, Jens; Gustafsson, Ida; Hansen, Henrik Steen

    CMD could be the explanation of angina pectoris with no obstructive CAD and may cause ventricular repolarization changes. We compared T-wave morphology and QTc interval in women with angina pectoris with a control group as well as the associations with CMD. Women with angina pectoris and no obstructive coronary artery disease (n=138) and age-matched controls were compared in regard to QTc interval and morphology combination score (MCS) based on T-wave asymmetry, flatness and presence of T-wave notch. CMD was assessed as a coronary flow velocity reserve (CFVR) by transthoracic echocardiography. Women with angina pectoris had significantly longer QTc intervals (429±20ms) and increased MCS (IQR) (0.73 [0.64-0.80]) compared with the controls (419±20ms) and (0.63 [(0.53-0.73]), respectively (both p<0.001). CFVR was associated with longer QTc interval (p=0.02), but the association was attenuated after multivariable adjustment (p=0.08). This study suggests that women with angina pectoris have alterations in T-wave morphology as well as longer QTc interval compared with a reference population. CMD might be an explanation. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Cross-correlation of heartbeat and respiration rhythms

    NASA Astrophysics Data System (ADS)

    Capurro, A.; Malta, C. P.; Diambra, L.; Contreras, P.; Migliaro, E. R.

    2005-10-01

    The cross-correlation function between respiration and heart beat interval series shows that during metronomized breathing the heart beat follows the respiration more closely than during spontaneous breathing. We reproduced the heart beat interval modulations during metronomized breathing using a biophysical model of the sinoatrial node excited by an input signal formed by the recorded respiration. In the case of spontaneous breathing, a good agreement with the experimental data was obtained only by using an input signal formed by the sum of the recorded respiration and a realization of correlated noise. Metronomized breathing refers to the situation where a subject breathes following the rhythm of a metronome.

  18. The geomagnetic jerk of 1969 and the DGRFs

    USGS Publications Warehouse

    Thompson, D.; Cain, J.C.

    1987-01-01

    Cubic spline fits to the DGRF/IGRF series indicate agreement with other analyses showing the 1969-1970 magnetic jerk in the h ??12 and g ??02 secular change coefficients, and agreement that the h ??11 term showed no sharp change. The variation of the g ??01 term is out of phase with other analyses indicating a likely error in its representation in the 1965-1975 interval. We recommend that future derivations of the 'definitive' geomagnetic reference models take into consideration the times of impulses or jerks so as to not be bound to a standard 5 year interval, and otherwise to make more considered analyses before adopting sets of coefficients. ?? 1987.

  19. Diabetic retinopathy screening using deep neural network.

    PubMed

    Ramachandran, Nishanthan; Hong, Sheng Chiong; Sime, Mary J; Wilson, Graham A

    2017-09-07

    There is a burgeoning interest in the use of deep neural network in diabetic retinal screening. To determine whether a deep neural network could satisfactorily detect diabetic retinopathy that requires referral to an ophthalmologist from a local diabetic retinal screening programme and an international database. Retrospective audit. Diabetic retinal photos from Otago database photographed during October 2016 (485 photos), and 1200 photos from Messidor international database. Receiver operating characteristic curve to illustrate the ability of a deep neural network to identify referable diabetic retinopathy (moderate or worse diabetic retinopathy or exudates within one disc diameter of the fovea). Area under the receiver operating characteristic curve, sensitivity and specificity. For detecting referable diabetic retinopathy, the deep neural network had an area under receiver operating characteristic curve of 0.901 (95% confidence interval 0.807-0.995), with 84.6% sensitivity and 79.7% specificity for Otago and 0.980 (95% confidence interval 0.973-0.986), with 96.0% sensitivity and 90.0% specificity for Messidor. This study has shown that a deep neural network can detect referable diabetic retinopathy with sensitivities and specificities close to or better than 80% from both an international and a domestic (New Zealand) database. We believe that deep neural networks can be integrated into community screening once they can successfully detect both diabetic retinopathy and diabetic macular oedema. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  20. Insufficient filling of vacuum tubes as a cause of microhemolysis and elevated serum lactate dehydrogenase levels. Use of a data-mining technique in evaluation of questionable laboratory test results.

    PubMed

    Tamechika, Yoshie; Iwatani, Yoshinori; Tohyama, Kaoru; Ichihara, Kiyoshi

    2006-01-01

    Experienced physicians noted unexpectedly elevated concentrations of lactate dehydrogenase in some patient samples, but quality control specimens showed no bias. To evaluate this problem, we used a "latent reference individual extraction method", designed to obtain reference intervals from a laboratory database by excluding individuals who have abnormal results for basic analytes other than the analyte in question, in this case lactate dehydrogenase. The reference interval derived for the suspected year was 264-530 U/L, while that of the previous year was 248-495 U/L. The only change we found was the introduction of an order entry system, which requests precise sampling volumes rather than complete filling of vacuum tubes. The effect of vacuum persistence was tested using ten freshly drawn blood samples. Compared with complete filling, 1/5 filling resulted in average elevations of lactate dehydrogenase, aspartic aminotransferase, and potassium levels of 8.0%, 3.8%, and 3.4%, respectively (all p<0.01). Microhemolysis was confirmed using a urine stick method. The length of time before centrifugation determined the degree of hemolysis, while vacuum during centrifugation did not affect it. Microhemolysis is the probable cause of the suspected pseudo-elevation noted by the physicians. Data-mining methodology represents a valuable tool for monitoring long-term bias in laboratory results.

  1. A sensitive LC-MS/MS method for the quantification of urinary 8-iso-prostaglandin F2α (8-iso-PGF2α) including pediatric reference interval.

    PubMed

    Xiao, Yi; Fu, Xiaowei; Pattengale, Paul; Dien Bard, Jennifer; Xu, Yan-Kang; O'Gorman, Maurice R

    2016-09-01

    Oxidative stress has been implicated in numerous diseases, including arthritis, atherosclerosis, Alzheimer's disease, cancer, diabetes, hypertension, and inflammation. 8-iso-prostaglandin F2α, a member of the F2 isoprostane family, has been well-accepted as a valuable biomarker for the assessment of oxidative stress. We report the development and validation of an ultra-sensitive LC-MS/MS assay for urinary 8-iso-PGF2α measurements in pediatric population. The assay was linear from 0.024 to 20nmol/l (R(2)=0.99). Recoveries were above 85% and matrix effects were below 5%. The variability was determined at nmol/l concentration: the intra-day variability (%CV) ranged from 3.9% to 4.5% (n=20); and the inter-day variability ranged from 4.3% to 5.7% (n=20). The accuracy of our laboratory developed test was evaluated with a clinical reference laboratory (n=39), and a correlation coefficient of 0.9257 was observed. Reference interval were established to be <0.5ng/mg creatinine in a group of pediatric population (2months-18years, n=123). The precision of the assay will allow for accurate assessment of oxidative stress, and is acceptable for patient testing, particularly in pediatric population. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Pharmacokinetics and Bioequivalence Evaluation of 2 Loxoprofen Tablets in Healthy Egyptian Male Volunteers.

    PubMed

    Helmy, Sally A

    2013-04-01

    The objective of this study was to assess the in vitro dissolution and to evaluate the bioavailability of two brands of Loxoprofen sodium dihydrate tablets. Loxoprofen tablets (68.1 mg loxoprofen sodium dihydrate equivalent to 60 mg loxoprofen; test) relative to Roxonin tablets (68.1 mg loxoprofen sodium dihydrate equivalent to 60 mg loxoprofen; reference). In vitro study was adopted to determine and compare the dissolution behavior of both products. In vivo study was conducted according to a single-center, randomized, single-dose, and laboratory-blinded, 2-period, 2-sequence, crossover design with a washout period of 1 week. Under fasting conditions, 24 healthy Egyptian adult male volunteers were randomly allocated to receive a single dose of either test or reference product. Blood samples were collected at specified time intervals, and plasma was analyzed for loxoprofen concentrations using a validated high-performance liquid chromatography assay method. The pharmacokinetic parameters Cmax , AUC0-t , AUC0-∞ , tmax , and t1/2 were determined from plasma concentration-time profiles. The 90% confidence intervals for the ratio Cmax , AUC0-t , and AUCt-∞ of the test product over those of reference were within the acceptable range (0.8-1.25) for bioequivalence. On the basis of these results, the two-loxoprofen formulations are considered bioequivalent. © The Author(s) 2013.

  3. Association between interpregnancy interval and future risk of maternal cardiovascular disease-a population-based record linkage study.

    PubMed

    Ngo, A D; Roberts, C L; Figtree, G

    2016-07-01

    To examine the associations between interpregnancy interval and later maternal cardiovascular disease (CVD) risk. Population-based record linkage study. New South Wales, Australia, 1994-2011. 216 467 women having first and second liveborn singleton infants, excluding those with an existing or pregnancy-related CVD risk factor. We linked birth records of mothers to the mothers' subsequent CVD (coronary heart disease, cerebrovascular events, and chronic heart failure) hospitalisation or death. Multivariable Cox proportional hazard regression was used to estimate adjusted hazard ratios (AHR) [95% confidence interval (CI)], accounting for maternal age, parity, socioeconomic status, and smoking during pregnancy. The first occurrence of a CVD hospitalisation or death after the second birth. In comparison with mothers with an interpregnancy interval of 18-23 months (reference category), the AHR among mothers with interpregnancy interval of <12 months was 1.56 (95% CI 1.18-2.07) and of 12-17 months was 1.13 (95% CI 0.84-1.51). The AHRs were 1.40 (95% CI 1.07-1.82), 1.87 (95% CI 1.21-2.89), and 3.41 (95% CI 1.07-10.91), corresponding to interpregnancy intervals of 24-59, 60-119, and ≥120 months, respectively. AHRs of specific CVD categories showed a similar pattern. Interpregnancy interval is associated with the risk of subsequent maternal CVD in a J-shaped fashion. The association is independent of the existing and pregnancy-related CVD risk factors analysed. Both short and long interpregnancy intervals can be used as risk markers to identify women with an elevated CVD risk later in life. Interpregnancy interval is associated with the risk of subsequent maternal cardiovascular disease in a J-shaped fashion. © 2015 Royal College of Obstetricians and Gynaecologists.

  4. 40 CFR 1065.140 - Dilution for gaseous and PM constituents.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... nitrogen. References in this part to “dilution air” may include any of these. For gaseous emission... test interval does not exceed the specified limits. (A) Use chemical balance equations in § 1065.655 to... balance), and set any negative values to zero. This difference is the potential mole fraction of the...

  5. Spectral Analysis; Applications in Water Pollution Control.

    ERIC Educational Resources Information Center

    Wastler, T. A.

    The statistical technique of analyzing data collected at regular intervals to reveal periodic components of the data is described by reference to actual records. The data chosen for illustration include tide height in a river; biochemical oxygen demand and dissolved oxygen in the same river; discharged salt into a river system and its relation to…

  6. 31 CFR 342.3 - Extended terms and yields for outstanding notes.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 31 Money and Finance: Treasury 2 2014-07-01 2014-07-01 false Extended terms and yields for... SAVINGS NOTES § 342.3 Extended terms and yields for outstanding notes. (a) Extended maturity periods. The terms extended maturity period and second extended maturity period refer to the 10-year intervals after...

  7. 31 CFR 342.3 - Extended terms and yields for outstanding notes.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 31 Money and Finance:Treasury 2 2011-07-01 2011-07-01 false Extended terms and yields for... SAVINGS NOTES § 342.3 Extended terms and yields for outstanding notes. (a) Extended maturity periods. The terms extended maturity period and second extended maturity period refer to the 10-year intervals after...

  8. 31 CFR 342.3 - Extended terms and yields for outstanding notes.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Extended terms and yields for... SAVINGS NOTES § 342.3 Extended terms and yields for outstanding notes. (a) Extended maturity periods. The terms extended maturity period and second extended maturity period refer to the 10-year intervals after...

  9. 31 CFR 342.3 - Extended terms and yields for outstanding notes.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 31 Money and Finance:Treasury 2 2013-07-01 2013-07-01 false Extended terms and yields for... SAVINGS NOTES § 342.3 Extended terms and yields for outstanding notes. (a) Extended maturity periods. The terms extended maturity period and second extended maturity period refer to the 10-year intervals after...

  10. 31 CFR 342.3 - Extended terms and yields for outstanding notes.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance:Treasury 2 2012-07-01 2012-07-01 false Extended terms and yields for... SAVINGS NOTES § 342.3 Extended terms and yields for outstanding notes. (a) Extended maturity periods. The terms extended maturity period and second extended maturity period refer to the 10-year intervals after...

  11. 21 CFR 510.301 - Records and reports concerning experience with animal feeds bearing or containing new animal...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS NEW ANIMAL DRUGS Records... reported, appropriately identified with the new animal drug application(s) or index listing(s) to which... designated intervals. Unexpected as used in this paragraph refers to conditions or developments not...

  12. Distinguishing hyperhidrosis and normal physiological sweat production: new data and review of hyperhidrosis data for 1980-2013.

    PubMed

    Thorlacius, Linnea; Gyldenløve, Mette; Zachariae, Claus; Carlsen, Berit C

    2015-10-01

    Hyperhidrosis is a condition in which the production of sweat is abnormally increased. No objective criteria for the diagnosis of hyperhidrosis exist, mainly because reference intervals for normal physiological sweat production at rest are unknown. The main objective of this study was to establish reference intervals for normal physiological axillary and palmar sweat production. Gravimetric testing was performed in 75 healthy control subjects. Subsequently, these results were compared with findings in a cohort of patients with hyperhidrosis and with the results derived from a review of data on hyperhidrosis published between 1980 and 2013. Approximately 90% of the controls had axillary and palmar sweat production rates of below 100 mg/5 min. In all except one of the axillary and palmar hyperhidrosis studies reviewed, average sweat production exceeded 100 mg/5 min. A sweat production rate of 100 mg/5 min as measured by gravimetric testing may be a reasonable cut-off value for distinguishing axillary and palmar hyperhidrosis from normal physiological sweat production. © 2015 The International Society of Dermatology.

  13. Modeling Geomagnetically Induced Currents From Magnetometer Measurements: Spatial Scale Assessed With Reference Measurements

    NASA Astrophysics Data System (ADS)

    Butala, Mark D.; Kazerooni, Maryam; Makela, Jonathan J.; Kamalabadi, Farzad; Gannon, Jennifer L.; Zhu, Hao; Overbye, Thomas J.

    2017-10-01

    Solar-driven disturbances generate geomagnetically induced currents (GICs) that can result in power grid instability and, in the most extreme cases, even failure. Magnetometers provide direct measurements of the geomagnetic disturbance (GMD) effect on the surface magnetic field and GIC response can be determined from the power grid topology and engineering parameters. This paper considers this chain of models: transforming surface magnetic field disturbance to induced surface electric field through an electromagnetic transfer function and, then, induced surface electric field to GIC using the PowerWorld simulator to model a realistic power grid topology. Comparisons are made to transformer neutral current reference measurements provided by the American Transmission Company. Three GMD intervals are studied, with the Kp index reaching 8- on 2 October 2013, 7 on 1 June 2013, and 6- on 9 October 2013. Ultimately, modeled to measured GIC correlations are analyzed as a function of magnetometer to GIC sensor distance. Results indicate that modeling fidelity during the three studied GMD intervals is strongly dependent on both magnetometer to substation transformer baseline distance and GMD intensity.

  14. Serum and Plasma Cholinesterase Activity in the Cape Griffon Vulture (Gyps coprotheres).

    PubMed

    Naidoo, Vinny; Wolter, Kerri

    2016-04-28

    Vulture (Accipitridae) poisonings are a concern in South Africa, with hundreds of birds dying annually. Although some of these poisonings are accidental, there has been an increase in the number of intentional baiting of poached rhinoceros (Rhinocerotidae) and elephant (Elephantidae) carcasses to kill vultures that alert officials to poaching sites by circling overhead. The primary chemicals implicated are the organophosphorous and carbamate compounds. Although most poisoning events can be identified by dead vultures surrounding the scavenged carcass, weak birds are occasionally found and brought to rehabilitation centers for treatment. The treating veterinarian needs to make an informed decision on the cause of illness or poisoning prior to treatment. We established the reference interval for serum and plasma cholinesterase activity in the Cape Griffon Vulture ( Gyps coprotheres ) as 591.58-1,528.26 U/L, providing a clinical assay for determining potential exposure to cholinesterase-depressing pesticides. Both manual and automated samplers were used with the butyrylthiocholine method. Species reference intervals for both serum and plasma cholinesterase showed good correlation and manual and automated measurements yielded similar results.

  15. Reference Values of 14 Serum Trace Elements for Pregnant Chinese Women: A Cross-Sectional Study in the China Nutrition and Health Survey 2010–2012

    PubMed Central

    Liu, Xiaobing; Zhang, Yu; Piao, Jianhua; Mao, Deqian; Li, Yajie; Li, Weidong; Yang, Lichen; Yang, Xiaoguang

    2017-01-01

    The development of reference values of trace elements is recognized as a fundamental prerequisite for the assessment of trace element nutritional status and health risks. In this study, a total of 1400 pregnant women aged 27.0 ± 4.5 years were randomly selected from the China Nutrition and Health Survey 2010–2012 (CNHS 2010–2012). The concentrations of 14 serum trace elements were determined by high-resolution inductively coupled plasma mass spectrometry. Reference values were calculated covering the central 95% reference intervals (P2.5–P97.5) after excluding outliers by Dixon’s test. The overall reference values of serum trace elements were 131.5 (55.8-265.0 μg/dL for iron (Fe), 195.5 (107.0–362.4) μg/dL for copper (Cu), 74.0 (51.8–111.3) μg/dL for zinc (Zn), 22.3 (14.0–62.0) μg/dL for rubidium (Rb), 72.2 (39.9–111.6) μg/L for selenium (Se), 45.9 (23.8-104.3) μg/L for strontium (Sr), 1.8 (1.2–3.6) μg/L for molybdenum (Mo), 2.4 (1.2–8.4) μg/L for manganese (Mn), 1.9 (0.6–9.0) ng/L for lead (Pb), 1.1 (0.3-5.6) ng/L for arsenic (As), 835.6 (219.8–4287.7) ng/L for chromium (Cr), 337.9 (57.0–1130.0) ng/L for cobalt (Co), 193.2 (23.6–2323.1) ng/L for vanadium (V), and 133.7 (72.1–595.1) ng/L for cadmium (Cd). Furthermore, some significant differences in serum trace element reference values were observed between different groupings of age intervals, residences, anthropometric status, and duration of pregnancy. We found that serum Fe, Zn, and Se concentrations significantly decreased, whereas serum Cu, Sr, and Co concentrations elevated progressively compared with reference values of 14 serum trace elements in pregnant Chinese women. The reference values of serum trace elements established could play a key role in the following nutritional status and health risk assessment. PMID:28335545

  16. A long-range and long-life telemetry data-acquisition system for heart rate and multiple body temperatures from free-ranging animals

    NASA Technical Reports Server (NTRS)

    Lund, G. F.; Westbrook, R. M.; Fryer, T. B.; Miranda, R. F.

    1979-01-01

    The system includes an implantable transmitter, external receiver-retransmitter collar, and a microprocessor-controlled demodulator. The size of the implant is suitable for animals with body weights of a few kilograms or more; further size reduction of the implant is possible. The ECG is sensed by electrodes designed for internal telemetry and to reduce movement artifacts. The R-wave characteristics are then specifically selected to trigger a short radio frequency pulse. Temperatures are sensed at desired locations by thermistors and then, based on a heartbeat counter, transmitted intermittently via pulse interval modulation. This modulation scheme includes first and last calibration intervals for a reference by ratios with the temperature intervals to achieve good accuracy even over long periods. Pulse duration and pulse sequencing are used to discriminate between heart rate and temperature pulses as well as RF interference.

  17. Determination of propranolol hydrochloride in pharmaceutical preparations using near infrared spectrometry with fiber optic probe and multivariate calibration methods.

    PubMed

    Marques Junior, Jucelino Medeiros; Muller, Aline Lima Hermes; Foletto, Edson Luiz; da Costa, Adilson Ben; Bizzi, Cezar Augusto; Irineu Muller, Edson

    2015-01-01

    A method for determination of propranolol hydrochloride in pharmaceutical preparation using near infrared spectrometry with fiber optic probe (FTNIR/PROBE) and combined with chemometric methods was developed. Calibration models were developed using two variable selection models: interval partial least squares (iPLS) and synergy interval partial least squares (siPLS). The treatments based on the mean centered data and multiplicative scatter correction (MSC) were selected for models construction. A root mean square error of prediction (RMSEP) of 8.2 mg g(-1) was achieved using siPLS (s2i20PLS) algorithm with spectra divided into 20 intervals and combination of 2 intervals (8501 to 8801 and 5201 to 5501 cm(-1)). Results obtained by the proposed method were compared with those using the pharmacopoeia reference method and significant difference was not observed. Therefore, proposed method allowed a fast, precise, and accurate determination of propranolol hydrochloride in pharmaceutical preparations. Furthermore, it is possible to carry out on-line analysis of this active principle in pharmaceutical formulations with use of fiber optic probe.

  18. How do gait frequency and serum-replacement interval affect polyethylene wear in knee-wear simulator tests?

    PubMed

    Reinders, Jörn; Sonntag, Robert; Kretzer, Jan Philippe

    2014-11-01

    Polyethylene wear (PE) is known to be a limiting factor in total joint replacements. However, a standardized wear test (e.g. ISO standard) can only replicate the complex in vivo loading condition in a simplified form. In this study, two different parameters were analyzed: (a) Bovine serum, as a substitute for synovial fluid, is typically replaced every 500,000 cycles. However, a continuous regeneration takes place in vivo. How does serum-replacement interval affect the wear rate of total knee replacements? (b) Patients with an artificial joint show reduced gait frequencies compared to standardized testing. What is the influence of a reduced frequency? Three knee wear tests were run: (a) reference test (ISO), (b) testing with a shortened lubricant replacement interval, (c) testing with reduced frequency. The wear behavior was determined based on gravimetric measurements and wear particle analysis. The results showed that the reduced test frequency only had a small effect on wear behavior. Testing with 1 Hz frequency is therefore a valid method for wear testing. However, testing with a shortened replacement interval nearly doubled the wear rate. Wear particle analysis revealed only small differences in wear particle size between the different tests. Wear particles were not linearly released within one replacement interval. The ISO standard should be revised to address the marked effects of lubricant replacement interval on wear rate.

  19. Baseline Morbidity in 2,990 Adult African Volunteers Recruited to Characterize Laboratory Reference Intervals for Future HIV Vaccine Clinical Trials

    PubMed Central

    Stevens, Wendy; Kamali, Anatoli; Karita, Etienne; Anzala, Omu; Sanders, Eduard J.; Jaoko, Walter; Kaleebu, Pontiano; Mulenga, Joseph; Dally, Len; Fast, Pat; Gilmour, Jill; Farah, Bashir; Birungi, Josephine; Hughes, Peter; Manigart, Olivier; Stevens, Gwynn; Yates, Sarah; Thomson, Helen; von Lieven, Andrea; Krebs, Marietta; Price, Matt A.; Stoll-Johnson, Lisa; Ketter, Nzeera

    2008-01-01

    Background An understanding of the health of potential volunteers in Africa is essential for the safe and efficient conduct of clinical trials, particularly for trials of preventive technologies such as vaccines that enroll healthy individuals. Clinical safety laboratory values used for screening, enrolment and follow-up of African clinical trial volunteers have largely been based on values derived from industrialized countries in Europe and North America. This report describes baseline morbidity during recruitment for a multi-center, African laboratory reference intervals study. Methods Asymptomatic persons, aged 18–60 years, were invited to participate in a cross-sectional study at seven sites (Kigali, Rwanda; Masaka and Entebbe, Uganda; Kangemi, Kenyatta National Hospital and Kilifi, Kenya; and Lusaka, Zambia). Gender equivalency was by design. Individuals who were acutely ill, pregnant, menstruating, or had significant clinical findings were not enrolled. Each volunteer provided blood for hematology, immunology, and biochemistry parameters and urine for urinalysis. Enrolled volunteers were excluded if found to be positive for HIV, syphilis or Hepatitis B and C. Laboratory assays were conducted under Good Clinical Laboratory Practices (GCLP). Results and Conclusions Of the 2990 volunteers who were screened, 2387 (80%) were enrolled, and 2107 (71%) were included in the analysis (52% men, 48% women). Major reasons for screening out volunteers included abnormal findings on physical examination (228/603, 38%), significant medical history (76, 13%) and inability to complete the informed consent process (73, 13%). Once enrolled, principle reasons for exclusion from analysis included detection of Hepatitis B surface antigen (106/280, 38%) and antibodies against Hepatitis C (95, 34%). This is the first large scale, multi-site study conducted to the standards of GCLP to describe African laboratory reference intervals applicable to potential volunteers in clinical trials. Approximately one-third of all potential volunteers screened were not eligible for analysis; the majority were excluded for medical reasons. PMID:18446196

  20. Earth's portfolio of extreme sediment transport events

    NASA Astrophysics Data System (ADS)

    Korup, Oliver

    2012-05-01

    Quantitative estimates of sediment flux and the global cycling of sediments from hillslopes to rivers, estuaries, deltas, continental shelves, and deep-sea basins have a long research tradition. In this context, extremely large and commensurately rare sediment transport events have so far eluded a systematic analysis. To start filling this knowledge gap I review some of the highest reported sediment yields in mountain rivers impacted by volcanic eruptions, earthquake- and storm-triggered landslide episodes, and catastrophic dam breaks. Extreme specific yields, defined here as those exceeding the 95th percentile of compiled data, are ~ 104 t km- 2 yr- 1 if averaged over 1 yr. These extreme yields vary by eight orders of magnitude, but systematically decay with reference intervals from minutes to millennia such that yields vary by three orders of magnitude for a given reference interval. Sediment delivery from natural dam breaks and pyroclastic eruptions dominate these yields for a given reference interval. Even if averaged over 102-103 yr, the contribution of individual disturbances may remain elevated above corresponding catchment denudation rates. I further estimate rates of sediment (re-)mobilisation by individual giant terrestrial and submarine mass movements. Less than 50 postglacial submarine mass movements have involved an equivalent of ~ 10% of the contemporary annual global flux of fluvial sediment to Earth's oceans, while mobilisation rates by individual events rival the decadal-scale sediment discharge from tectonically active orogens such as Taiwan or New Zealand. Sediment flushing associated with catastrophic natural dam breaks is non-stationary and shows a distinct kink at the last glacial-interglacial transition, owing to the drainage of very large late Pleistocene ice-marginal lakes. Besides emphasising the contribution of high-magnitude and low-frequency events to the global sediment cascade, these findings stress the importance of sediment storage for fuelling rather than buffering high sediment transport rates.

  1. Interlaboratory comparison for the measurement of particle size and zeta potential of silica nanoparticles in an aqueous suspension

    NASA Astrophysics Data System (ADS)

    Lamberty, Andrée; Franks, Katrin; Braun, Adelina; Kestens, Vikram; Roebben, Gert; Linsinger, Thomas P. J.

    2011-12-01

    The Institute for Reference Materials and Measurements has organised an interlaboratory comparison (ILC) to allow the participating laboratories to demonstrate their proficiency in particle size and zeta potential measurements on monomodal aqueous suspensions of silica nanoparticles in the 10-100 nm size range. The main goal of this ILC was to identify competent collaborators for the production of certified nanoparticle reference materials. 38 laboratories from four different continents participated in the ILC with different methods for particle sizing and determination of zeta potential. Most of the laboratories submitted particle size results obtained with centrifugal liquid sedimentation (CLS), dynamic light scattering (DLS) or electron microscopy (EM), or zeta potential values obtained via electrophoretic light scattering (ELS). The results of the laboratories were evaluated using method-specific z scores, calculated on the basis of consensus values from the ILC. For CLS (13 results) and EM (13 results), all reported values were within the ±2 | z| interval. For DLS, 25 of the 27 results reported were within the ±2 | z| interval, the two other results were within the ±3 | z| interval. The standard deviations of the corresponding laboratory mean values varied between 3.7 and 6.5%, which demonstrates satisfactory interlaboratory comparability of CLS, DLS and EM particle size values. From the received test reports, a large discrepancy was observed in terms of the laboratory's quality assurance systems, which are equally important for the selection of collaborators in reference material certification projects. Only a minority of the participating laboratories is aware of all the items that are mandatory in test reports compliant to ISO/IEC 17025 (ISO General requirements for the competence of testing and calibration laboratories. International Organisation for Standardization, Geneva, 2005b). The absence of measurement uncertainty values in the reports, for example, hindered the calculation of zeta scores.

  2. Clinical Pathology Reference Intervals for an In-Water Population of Juvenile Loggerhead Sea Turtles (Caretta caretta) in Core Sound, North Carolina, USA

    PubMed Central

    Kelly, Terra R.; McNeill, Joanne Braun; Avens, Larisa; Hall, April Goodman; Goshe, Lisa R.; Hohn, Aleta A.; Godfrey, Matthew H.; Mihnovets, A. Nicole; Cluse, Wendy M.; Harms, Craig A.

    2015-01-01

    The loggerhead sea turtle (Caretta caretta) is found throughout the waters of the Atlantic, Pacific, and Indian Oceans. It is a protected species throughout much of its range due to threats such as habitat loss, fisheries interactions, hatchling predation, and marine debris. Loggerheads that occur in the southeastern U.S. are listed as “threatened” on the U.S. Endangered Species List, and receive state and federal protection. As part of an on-going population assessment conducted by the National Marine Fisheries Service, samples were collected from juvenile loggerhead sea turtles in Core Sound, North Carolina, between 2004 and 2007 to gain insight on the baseline health of the threatened Northwest Atlantic Ocean population. The aims of the current study were to establish hematologic and biochemical reference intervals for this population, and to assess variation of the hematologic and plasma biochemical analytes by season, water temperature, and sex and size of the turtles. Reference intervals for the clinical pathology parameters were estimated following Clinical Laboratory Standards Institute guidelines. Season, water temperature, sex, and size of the turtles were found to be significant factors of variation for parameter values. Seasonal variation could be attributed to physiological effects of decreasing photoperiod, cooler water temperature, and migration during the fall months. Packed cell volume, total protein, and albumin increased with increasing size of the turtles. The size-related differences in analytes documented in the present study are consistent with other reports of variation in clinical pathology parameters by size and age in sea turtles. As a component of a health assessment of juvenile loggerhead sea turtles in North Carolina, this study will serve as a baseline aiding in evaluation of trends for this population and as a diagnostic tool for assessing the health and prognosis for loggerhead sea turtles undergoing rehabilitation. PMID:25738772

  3. Clinical pathology reference intervals for an in-water population of juvenile loggerhead sea turtles (Caretta caretta) in Core Sound, North Carolina, USA.

    PubMed

    Kelly, Terra R; McNeill, Joanne Braun; Avens, Larisa; Hall, April Goodman; Goshe, Lisa R; Hohn, Aleta A; Godfrey, Matthew H; Mihnovets, A Nicole; Cluse, Wendy M; Harms, Craig A

    2015-01-01

    The loggerhead sea turtle (Caretta caretta) is found throughout the waters of the Atlantic, Pacific, and Indian Oceans. It is a protected species throughout much of its range due to threats such as habitat loss, fisheries interactions, hatchling predation, and marine debris. Loggerheads that occur in the southeastern U.S. are listed as "threatened" on the U.S. Endangered Species List, and receive state and federal protection. As part of an on-going population assessment conducted by the National Marine Fisheries Service, samples were collected from juvenile loggerhead sea turtles in Core Sound, North Carolina, between 2004 and 2007 to gain insight on the baseline health of the threatened Northwest Atlantic Ocean population. The aims of the current study were to establish hematologic and biochemical reference intervals for this population, and to assess variation of the hematologic and plasma biochemical analytes by season, water temperature, and sex and size of the turtles. Reference intervals for the clinical pathology parameters were estimated following Clinical Laboratory Standards Institute guidelines. Season, water temperature, sex, and size of the turtles were found to be significant factors of variation for parameter values. Seasonal variation could be attributed to physiological effects of decreasing photoperiod, cooler water temperature, and migration during the fall months. Packed cell volume, total protein, and albumin increased with increasing size of the turtles. The size-related differences in analytes documented in the present study are consistent with other reports of variation in clinical pathology parameters by size and age in sea turtles. As a component of a health assessment of juvenile loggerhead sea turtles in North Carolina, this study will serve as a baseline aiding in evaluation of trends for this population and as a diagnostic tool for assessing the health and prognosis for loggerhead sea turtles undergoing rehabilitation.

  4. Dose evaluation for paediatric chest x-ray examinations in Brazil and Sudan: low doses and reliable examinations can be achieved in developing countries

    NASA Astrophysics Data System (ADS)

    Mohamadain, K. E. M.; da Rosa, L. A. R.; Azevedo, A. C. P.; Guebel, M. R. N.; Boechat, M. C. B.; Habani, F.

    2004-03-01

    Radiation protection in paediatric radiology deserves special attention since it is assumed that children are more sensitive to radiation than adults. The aim of this work is to estimate the entrance skin dose (ESD), the body organ dose (BOD) and the effective dose (E) for chest x-ray exposure of paediatric patients in five large units, three in Sudan and two in Brazil, and to compare the results obtained in both countries with each other and with other values obtained by some European countries. Two examination projections have been investigated, namely, postero-anterior (PA) and antero-posterior (AP). The age intervals considered were: 0-1 year, 1-5 years, 5-10 years and 10-15 years. The results have been obtained with the use of a software called DoseCal. Results of mean ESD for the age interval 1-5 years and AP projection are: 66 µGy (Instituto de Pediatria e Puericultura Martagão Gesteira—IPPMG Hospital), 41, 86 and 68 µGy (Instituto Fernandes Figueira—IFF Hospital), 161 µGy (Omdurman Hospital), 395 µGy (Khartoum Hospital) and 23 µGy (Ahmed Gasim Hospital). In the case of the IFF Hospital, the results refer, respectively, to rooms 1, 2 and for the six mobile equipments. The reference dose values given by the European Guidelines were exceeded in the Khartoum Hospital whilst in all the other hospitals results obtained were below CEC reference values and comparable with the results found in Sweden, Germany, Spain and Italy. The mean E for the same age interval was 11 µSv in the IPPMG, 6, 15 and 11 µSv in the IFF, respectively for rooms 1, 2 and the 6 mobiles, 25 µSv in the Omdurman Hospital, 45 µSv in the Khartoum Hospital and 3 µSv in the Ahmed Gasim Hospital. These are some examples of the large discrepancies that have been detected in this survey.

  5. Evaluation of tricuspid annular plane systolic excursion measured by two-dimensional echocardiography in healthy dogs: repeatability, reference intervals, and comparison with M-mode assessment.

    PubMed

    Visser, L C; Sintov, D J; Oldach, M S

    2018-06-01

    We sought to determine the feasibility, measurement variability, and within-day repeatability of tricuspid annular plane systolic excursion (TAPSE) measured by two-dimensional echocardiography (2D TAPSE), generate reference intervals for 2D TAPSE, assess agreement and correlation between 2D TAPSE and the conventional TAPSE measured by M-mode echocardiography (MM TAPSE), and to assess the ability of 2D TAPSE to track a drug-induced decrease in right ventricular (RV) function compared with MM TAPSE. Seventy healthy privately owned dogs of varying bodyweight. All dogs underwent a single echocardiogram to quantify RV function by both TAPSE methods. Ten dogs underwent a second echocardiogram 2-3 h after the first to assess within-day repeatability, and 20 different dogs underwent a second echocardiogram 3-h after atenolol (1 mg/kg per os (PO)). Intraobserver and interobserver measurement variabilities were assessed in 12 randomly selected studies using coefficients of variation. Statistical relationships between 2D TAPSE and bodyweight, gender, heart rate, and age were explored. 2D TAPSE could be measured in all dogs. Coefficients of variation for repeatability and measurement variability were low (≤12%). Bodyweight-dependent reference intervals for 2D TAPSE were generated using allometric scaling. TAPSE methods were strongly correlated (r = 0.72; p<0.0001) but 2D TAPSE measured consistently less than MM TAPSE (-1.6 [2.2] mm) when analyzed by Bland-Altman's method. Both TAPSE methods were significantly (p≤0.014) reduced after atenolol but percent decrease in 2D TAPSE (-16.2 [9.3]%) was significantly greater (p=0.03) than MM TAPSE (-7.5 [13.8]%). Two-dimensional echocardiography TAPSE appears well suited for clinical assessment of RV function. The TAPSE methods should not be used interchangeably. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Auditory evoked potential P300 in adults: reference values

    PubMed Central

    Didoné, Dayane Domeneghini; Garcia, Michele Vargas; Oppitz, Sheila Jacques; da Silva, Thalisson Francisco Finamôr; dos Santos, Sinéia Neujahr; Bruno, Rúbia Soares; Filha, Valdete Alves Valentins dos Santos; Cóser, Pedro Luis

    2016-01-01

    ABSTRACT Objective To establish reference intervals for cognitive potential P300 latency using tone burst stimuli. Methods This study involved 28 participants aged between 18 and 59 years. P300 recordings were performed using a two-channel device (Masbe, Contronic). Electrode placement was as follows: Fpz (ground electrode), Cz (active electrode), M1 and M2 (reference electrodes). Intensity corresponded to 80 dB HL and frequent and rare stimulus frequencies to 1,000Hz and 2,000Hz, respectively. Stimuli were delivered binaurally. Results Mean age of participants was 35 years. Average P300 latency was 305ms. Conclusion Maximum acceptable P300 latency values of 362.5ms (305 + 2SD 28.75) were determined for adults aged 18 to 59 years using the protocol described. PMID:27462895

  7. USGS48 Puerto Rico precipitation - A new isotopic reference material for δ2H and δ18O measurements of water

    USGS Publications Warehouse

    Qi, Haiping; Coplen, Tyler B.; Tarbox, Lauren V.; Lorenz, Jennifer M.; Scholl, Martha A.

    2014-01-01

    A new secondary isotopic reference material has been prepared from Puerto Rico precipitation, which was filtered, homogenised, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and calibrated by dual-inlet isotope-ratio mass spectrometry. This isotopic reference material, designated as USGS48, is intended to be one of two isotopic reference waters for daily normalisation of stable hydrogen (δ2H) and stable oxygen (δ18O) isotopic analysis of water with a mass spectrometer or a laser absorption spectrometer. The δ2H and δ18O values of this reference water are−2.0±0.4 and−2.224±0.012 ‰, respectively, relative to Vienna Standard Mean Ocean Water on scales normalised such that the δ2H and δ18O values of Standard Light Antarctic Precipitation reference water are−428 and−55.5 ‰, respectively. Each uncertainty is an estimated expanded uncertainty (U=2uc) about the reference value that provides an interval that has about a 95 % probability of encompassing the true value. This isotopic reference water is available by the case of 144 glass ampoules containing 5 mL of water in each ampoule.

  8. Bioavailability of paracetamol, phenylephrine hydrochloride and guaifenesin in a fixed-combination syrup versus an oral reference product.

    PubMed

    Janin, Annick; Monnet, Joelle

    2014-04-01

    The primary objective of this study was to compare the bioavailability of paracetamol, phenylephrine hydrochloride and guaifenesin in a new oral syrup with an established oral reference product. The secondary objective was to compare the safety of the new syrup and the reference product. This was a single-centre, open-label, randomized, reference-replicated, crossover study. Healthy adult volunteers received one dose of syrup and two separate doses of a reference oral liquid formulation in a randomized sequence over three study periods, with a washout interval of ≥ 7 days between study periods. Blood samples were taken regularly postdose and analysed for paracetamol, phenylephrine hydrochloride and guaifenesin concentrations; adverse events were recorded. This study enrolled 45 subjects. For paracetamol and guaifenesin, the syrup and reference product were considered to be bioequivalent. Bioequivalence was not shown for phenylephrine hydrochloride. All adverse events were mild or moderate, most of which were considered formulation related. The syrup did not reach bioequivalence with the reference product, as bioequivalence could not be shown for phenylephrine hydrochloride. This may be due to differences in the excipients between the two products. Both the syrup and the reference product had a good safety profile and were well tolerated.

  9. Serum proteins by capillary zone electrophoresis: approaches to the definition of reference values.

    PubMed

    Petrini, C; Alessio, M G; Scapellato, L; Brambilla, S; Franzini, C

    1999-10-01

    The Paragon CZE 2000 (Beckman Analytical, Milan, Italy) is an automatic dedicated capillary zone electrophoresis (CZE) system, producing a five-zone serum protein pattern with quantitative estimation of the zones. With the view of substituting this instrument for two previously used serum protein electrophoresis techniques, we planned to produce reference values for the "new" systems leading to compatible interpretation of the results. High resolution cellulose acetate electrophoresis with visual inspection and descriptive reporting (HR-CAE) and five-zone cellulose acetate electrophoresis with densitometry (CAE-D) were the previously used techniques. Serum samples (n = 167) giving "normal pattern" with HR-CAE were assayed with the CZE system, and the results were statistically assessed to yield 0.95 reference intervals. One thousand normal and pathological serum samples were then assayed with the CAE-D and the CZE techniques, and the regression equations of the CAE-D values over the CZE values for the five zones were used to transform the CAE-D reference limits into the CZE reference limits. The two sets of reference values thereby produced were in good agreement with each other and also with reference values previously reported for the CZE system. Thus, reference values for the CZE techniques permit interpretation of results coherent with the previously used techniques and reporting modes.

  10. Diagnosis and classification of mastocytosis in non-specialized versus reference centres: a Spanish Network on Mastocytosis (REMA) study on 122 patients.

    PubMed

    Sánchez-Muñoz, Laura; Morgado, Jose M; Álvarez-Twose, Ivan; Matito, Almudena; Garcia-Montero, Andrés C; Teodosio, Cristina; Jara-Acevedo, Maria; Mayado, Andrea; Mollejo, Manuela; Caldas, Carolina; González de Olano, David; Escribano, Luis; Orfao, Alberto

    2016-01-01

    The diagnosis of 'rare diseases', such as mastocytosis, remains a challenge. Despite this, the precise benefits of referral of mastocytosis patients to highly specialized reference centres are poorly defined and whether patients should be managed at non-specialized versus reference centres remains a matter of debate. To evaluate the quality and efficiency of diagnostic procedures performed at the reference centres for mastocytosis in Spain (REMA) versus other non-reference centres, we retrospectively analysed a series of 122 patients, for the overall degree of agreement obtained for the World Health Organization (WHO) diagnostic and classification criteria betwen the referring and REMA centres. Our results showed that not all WHO diagnostic criteria were frequently investigated at the referring centres. Among the five WHO diagnostic criteria, the highest degree of agreement was obtained for serum tryptase levels [median 90% (95% confidence interval 84-96%)]; in turn, the overall agreement was significantly lower for the major histopathological criterion [80% (72-89%)], and the other three minor criteria: cytomorphology [68% (56-80%)] immunophenotyping of BM mast cells [75% (62-87%)] and detection of the KIT mutation [34% (8-60%)]. Referral of patients with diagnostic suspicion of mastocytosis to a multidisciplinary reference centre improves diagnostic efficiency and quality. © 2015 John Wiley & Sons Ltd.

  11. Quantitative Myocardial Perfusion Imaging Versus Visual Analysis in Diagnosing Myocardial Ischemia: A CE-MARC Substudy.

    PubMed

    Biglands, John D; Ibraheem, Montasir; Magee, Derek R; Radjenovic, Aleksandra; Plein, Sven; Greenwood, John P

    2018-05-01

    This study sought to compare the diagnostic accuracy of visual and quantitative analyses of myocardial perfusion cardiovascular magnetic resonance against a reference standard of quantitative coronary angiography. Visual analysis of perfusion cardiovascular magnetic resonance studies for assessing myocardial perfusion has been shown to have high diagnostic accuracy for coronary artery disease. However, only a few small studies have assessed the diagnostic accuracy of quantitative myocardial perfusion. This retrospective study included 128 patients randomly selected from the CE-MARC (Clinical Evaluation of Magnetic Resonance Imaging in Coronary Heart Disease) study population such that the distribution of risk factors and disease status was proportionate to the full population. Visual analysis results of cardiovascular magnetic resonance perfusion images, by consensus of 2 expert readers, were taken from the original study reports. Quantitative myocardial blood flow estimates were obtained using Fermi-constrained deconvolution. The reference standard for myocardial ischemia was a quantitative coronary x-ray angiogram stenosis severity of ≥70% diameter in any coronary artery of >2 mm diameter, or ≥50% in the left main stem. Diagnostic performance was calculated using receiver-operating characteristic curve analysis. The area under the curve for visual analysis was 0.88 (95% confidence interval: 0.81 to 0.95) with a sensitivity of 81.0% (95% confidence interval: 69.1% to 92.8%) and specificity of 86.0% (95% confidence interval: 78.7% to 93.4%). For quantitative stress myocardial blood flow the area under the curve was 0.89 (95% confidence interval: 0.83 to 0.96) with a sensitivity of 87.5% (95% confidence interval: 77.3% to 97.7%) and specificity of 84.5% (95% confidence interval: 76.8% to 92.3%). There was no statistically significant difference between the diagnostic performance of quantitative and visual analyses (p = 0.72). Incorporating rest myocardial blood flow values to generate a myocardial perfusion reserve did not significantly increase the quantitative analysis area under the curve (p = 0.79). Quantitative perfusion has a high diagnostic accuracy for detecting coronary artery disease but is not superior to visual analysis. The incorporation of rest perfusion imaging does not improve diagnostic accuracy in quantitative perfusion analysis. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. The use of reference change values in clinical laboratories.

    PubMed

    Bugdayci, Guler; Oguzman, Hamdi; Arattan, Havva Yasemin; Sasmaz, Guler

    2015-01-01

    The use of Reference Change Values (RCV) has been advocated as very useful for monitoring individuals. Most of these are performed for monitoring individuals in acute situations and for following up the improvement or deterioration of chronic diseases. In our study, we aimed at evaluating the RCV calculation for 24 clinical chemistry analytes widely used in clinical laboratories and the utilization of this data. Twenty-four serum samples were analyzed with Abbott kits (Abbott Laboratories, Abbott Park, IL, USA), manufactured for use with the Architect c8000 (Abbott Laboratories, Abbott Park, IL, USA) auto-analyzer. We calculated RCV using the following formula: RCV = Z x 2 1/2x (CVA2 + CVw2)1/2. Four reference change values (RCV) were calculated for each analyte using four statistical probabilities (0.95, and 0.99, unidirectional and bidirectional). Moreover, by providing an interval after identifying upper and lower limits with the Reference Change Factor (RCF), serially measured tests were calculated by using two formulas: exp (Z x 2 1/2 x (CV(A)2 + CVw2)½/100) for RCF(UP) and (1/RCF(UP)) for RCF(DOWN). RCVs of these analytes were calculated as 14.63% for glucose, 29.88% for urea, 17.75% for ALP, 53.39% for CK, 46.98% for CK-MB, 21.00% amylase, 8.00% for total protein, 8.70% for albumin, 51.08% for total bilirubin, 86.34% for direct bilirubin, 6.40% for calcium, 15.03% for creatinine, 21.47% for urate, 14.19% for total cholesterol, 46.62% for triglyceride, 20.51% for HDL-cholesterol, 29.59% for AST, 46.31% for ALT, 31.54% for GGT, 20.92% for LDH, 19.75% for inorganic phosphate, 3.05% for sodium, 11.75% for potassium, 4.44% for chloride (RCV, p < 0.05, unidirectionally). We suggest using RCV as well as using population-based reference intervals in clinical laboratories. RCV could be available as a tool for making clinical decision, especially when monitoring individuals.

  13. Reference Intervals of Routine Coagulation Assays During the Pregnancy and Puerperium Period.

    PubMed

    Gong, Jiao-Mei; Shen, Yong; He, Yan-Xia

    2016-11-01

    Significant changes occur in the coagulation and fibrinolytic systems during pregnancy and puerperium in the plasma levels. However, reference ranges based on healthy people are not optimal for informing clinical decisions during the pregnancy and puerperium. Therefore, it is essential to explore coagulation assays' reference ranges during the pregnancy and puerperium. Prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), fibrinogen (Fib.), and D-dimer were all measured according to the manufacturer's specifications and laboratory standard operating procedure of the STA-R evolution coagulation analyzer. A total of 11,601 women were enrolled in this study. The reference ranges for PT, APTT, TT, Fib., and D-dimer in nonpregnancy period were 10.87-13.76 s, 29.22-44.61 s, 15.39-20.15 s, 1.59-3.97 g/l, and 0-0.56 mg/l, respectively. In early-pregnancy period, the ranges were 11.14-14.07 s, 29.97-44.69 s, 14.92-19.03 s, 1.98-4.13 g/l, and 0-1.67 mg/l, respectively. In midpregnancy period, the ranges were 9.98-12.84 s, 28.53-40.70 s, 13.51-19.82 s, 2.63-5.19 g/l, and 0-2.81 mg/l, respectively. In late-pregnancy period, the ranges were 9.48-12.58 s, 28.61-40.80 s, 14.10-19.61 s, 2.80-5.56 g/l, and 0-27.08 mg/l, respectively. In puerperium period, the ranges were 10.85-13.72 s, 30.51-43.02 s, 15.31-19.64 s, 1.14-5.07 g/l, and 1.27-4.85 mg/l, respectively. We presented reference intervals for coagulation assays from the nonpregnancy to puerperium period that can be adopted in other laboratories after further validation. © 2016 Wiley Periodicals, Inc.

  14. The Asian project for collaborative derivation of reference intervals: (1) strategy and major results of standardized analytes.

    PubMed

    Ichihara, Kiyoshi; Ceriotti, Ferruccio; Tam, Tran Huu; Sueyoshi, Shigeo; Poon, Priscilla M K; Thong, Mee Ling; Higashiuesato, Yasushi; Wang, Xuejing; Kataoka, Hiromi; Matsubara, Akemi; Shiesh, Shu-Chu; Muliaty, Dewi; Kim, Jeong-Ho; Watanabe, Masakazu; Lam, Christopher W K; Siekmann, Lothar; Lopez, Joseph B; Panteghini, Mauro

    2013-07-01

    A multicenter study conducted in Southeast Asia to derive reference intervals (RIs) for 72 commonly measured analytes (general chemistry, inflammatory markers, hormones, etc.) featured centralized measurement to clearly detect regionality in test results. The results of 31 standardized analytes are reported, with the remaining analytes presented in the next report. The study included 63 clinical laboratories from South Korea, China, Vietnam, Malaysia, Indonesia, and seven areas in Japan. A total of 3541 healthy individuals aged 20-65 years (Japan 2082, others 1459) were recruited mostly from hospital workers using a well-defined common protocol. All serum specimens were transported to Tokyo at -80°C and collectively measured using reagents from four manufacturers. Three-level nested ANOVA was used to quantitate variation (SD) of test results due to region, sex, and age. A ratio of SD for a given factor over residual SD (representing net between-individual variations) (SDR) exceeding 0.3 was considered significant. Traceability of RIs was ensured by recalibration using value-assigned reference materials. RIs were derived parametrically. SDRs for sex and age were significant for 19 and 16 analytes, respectively. Regional difference was significant for 11 analytes, including high density lipoprotein (HDL)-cholesterol and inflammatory markers. However, when the data were limited to those from Japan, regionality was not observed in any of the analytes. Accordingly, RIs were derived with or without partition by sex and region. RIs applicable to a wide area in Asia were established for the majority of analytes with traceability to reference measuring systems, whereas regional partitioning was required for RIs of the other analytes.

  15. Pediatric primary care providers' perspectives regarding hospital discharge communication: a mixed methods analysis.

    PubMed

    Leyenaar, JoAnna K; Bergert, Lora; Mallory, Leah A; Engel, Richard; Rassbach, Caroline; Shen, Mark; Woehrlen, Tess; Cooperberg, David; Coghlin, Daniel

    2015-01-01

    Effective communication between inpatient and outpatient providers may mitigate risks of adverse events associated with hospital discharge. However, there is an absence of pediatric literature defining effective discharge communication strategies at both freestanding children's hospitals and general hospitals. The objectives of this study were to assess associations between pediatric primary care providers' (PCPs) reported receipt of discharge communication and referral hospital type, and to describe PCPs' perspectives regarding effective discharge communication and areas for improvement. We administered a questionnaire to PCPs referring to 16 pediatric hospital medicine programs nationally. Multivariable models were developed to assess associations between referral hospital type and receipt and completeness of discharge communication. Open-ended questions asked respondents to describe effective strategies and areas requiring improvement regarding discharge communication. Conventional qualitative content analysis was performed to identify emergent themes. Responses were received from 201 PCPs, for a response rate of 63%. Although there were no differences between referral hospital type and PCP-reported receipt of discharge communication (relative risk 1.61, 95% confidence interval 0.97-2.67), PCPs referring to general hospitals more frequently reported completeness of discharge communication relative to those referring to freestanding children's hospitals (relative risk 1.78, 95% confidence interval 1.26-2.51). Analysis of free text responses yielded 4 major themes: 1) structured discharge communication, 2) direct personal communication, 3) reliability and timeliness of communication, and 4) communication for effective postdischarge care. This study highlights potential differences in the experiences of PCPs referring to general hospitals and freestanding children's hospitals, and presents valuable contextual data for future quality improvement initiatives. Copyright © 2015 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  16. Ethnic Distribution of Microscopic Colitis in the United States.

    PubMed

    Turner, Kevin; Genta, Robert M; Sonnenberg, Amnon

    2015-11-01

    A large electronic database of histopathology reports was used to study the ethnic distribution of microscopic colitis in the United States. Miraca Life Sciences is a nation-wide pathology laboratory that receives biopsy specimens submitted by 1500 gastroenterologists distributed throughout the United States. In a case-control study, the prevalence of microscopic colitis in 4 ethnic groups (East Asians, Indians, Hispanics, and Jews) was compared with that of all other ethnic groups (composed of American Caucasians and African Americans), serving as reference group. A total of 11,706 patients with microscopic colitis were included in the analysis. In all ethnic groups alike, microscopic colitis was more common in women than men (78% versus 22%, odds ratio = 3.40, 95% confidence interval = 3.26-3.55). In all ethnic groups, the prevalence of microscopic colitis showed a continuous age-dependent rise. Hispanic patients with microscopic colitis were on average younger than the reference group (59.4 ± 16.2 years versus 64.2 ± 13.8 years, P < 0.001). Jewish patients with microscopic colitis were slightly older than the reference group (65.6 ± 13.4 years, P = 0.015). Compared with the reference group (prevalence = 1.20%), microscopic colitis was significantly less common among patients of Indian (prevalence = 0.28%, odds ratio = 0.32, 95% confidence interval = 0.13-0.65), East Asian (0.22%, 0.19, 0.14-0.26), or Hispanic decent (0.48%, 0.40, 0.36-0.45) and significantly more common among Jewish patients (1.30%, 1.10, 1.01-1.21). Microscopic colitis shows striking variations of its occurrence among different ethnic groups. Such variations could point at differences in the exposure to environmental risk factors.

  17. A prospective cohort study of stroke mortality and arsenic in drinking water in Bangladeshi adults

    PubMed Central

    2014-01-01

    Background Arsenic in drinking water causes increased coronary artery disease (CAD) and death from CAD, but its association with stroke is not known. Methods Prospective cohort study with arsenic exposure measured in well water at baseline. 61074 men and women aged 18 years or older on January 2003 were enrolled in 2003. The cohort was actively followed for an average of 7 years (421,754 person-years) through December 2010. Based on arsenic concentration the population was categorized in three groups and stroke mortality HR was compared to the referent. The risk of stroke mortality Hazard Ratio (HR) and 95% Confidence Interval was calculated in relation to arsenic exposure was estimated by Cox proportional hazard models with adjustment for potential confounders. Results A total of 1033 people died from stroke during the follow-up period, accounting for 23% of the total deaths. Multivariable adjusted HRs (95% confidence interval) for stroke for well water arsenic concentrations <10, 10-49, and ≥50 μg/L were 1.0 (reference), 1.20 (0.92 to 1.57), and 1.35 (1.04 to 1.75) respectively (Ptrend=0.00058). For men, multivariable adjusted HRs (95%) for well water arsenic concentrations <10, 10-49, and ≥50 μg/L were 1.0 (reference), 1.12 (0.78 to 1.60), and 1.07 (0.75 to 1.51) respectively (Ptrend=0.45) and for women 1.0 (reference),1.31 (0.87 to 1.98), and 1.72 (1.15 to 2.57) respectively (Ptrend=0.00004). Conclusion The result suggests that arsenic exposure was associated with increased stroke mortality risk in this population, and was more significant in women compared to men. PMID:24548416

  18. Hematology and Plasma Chemistry Reference Intervals for Mature Laboratory Pine Voles (Microtus pinetorum) as Determined by Using the Nonparametric Rank Percentile Method

    PubMed Central

    Harvey, Stephen B; Krimer, Paula M; Correa, Maria T; Hanes, Martha A

    2008-01-01

    Plasma biochemical and hematologic values are important parameters for assessing animal health and experimental results. Although normal reference values for many rodent species have been published, there is a dearth of similar information for the genus Microtus. In addition, most studies use a mean and standard deviation to establish reference intervals, but doing so is not the recommendation of the Clinical and Laboratory Standards Institute (formerly the National Committee on Clinical Laboratory Standards) or the International Federation of Clinical Chemistry and Laboratory Medicine. The purpose of this study was to establish normal reference parameters for plasma biochemistry and hematology in mature pine voles (Microtus pinetorum) by using the nonparametric rank percentile method as recommended by the 2 laboratory medicine organizations mentioned. Samples of cardiac blood from a closed colony of pine voles were collected at euthanasia and evaluated under rodent settings on 2 automated hematology analyzers from 2 different manufacturers and on the same type of automated biochemistry analyzer. There were no sex-associated clinically significant differences between the sexes; younger animals had a lower hematocrit, higher mean corpuscular volume, and lower mean corpuscular hemoglobin concentration than did older animals. Only platelet counts differed when comparing hematologic values from different analyzers. Relative to rats and mice, pine voles have a lower mean corpuscular volume and higher red blood cell count, higher blood urea nitrogen, much higher alanine aminotransferase, and lower glucose and phosphorous concentrations. Hematology and plasma biochemical results obtained in this study are considered representative for healthy adult laboratory pine voles under similar environmental conditions. PMID:18702449

  19. Spread of the dust temperature distribution in circumstellar disks

    NASA Astrophysics Data System (ADS)

    Heese, S.; Wolf, S.; Dutrey, A.; Guilloteau, S.

    2017-07-01

    Context. Accurate temperature calculations for circumstellar disks are particularly important for their chemical evolution. Their temperature distribution is determined by the optical properties of the dust grains, which, among other parameters, depend on their radius. However, in most disk studies, only average optical properties and thus an average temperature is assumed to account for an ensemble of grains with different radii. Aims: We investigate the impact of subdividing the grain radius distribution into multiple sub-intervals on the resulting dust temperature distribution and spectral energy distribution (SED). Methods: The temperature distribution, the relative grain surface below a certain temperature, the freeze-out radius, and the SED were computed for two different scenarios: (1) Radius distribution represented by 16 logarithmically distributed radius intervals, and (2) radius distribution represented by a single grain species with averaged optical properties (reference). Results: Within the considered parameter range, I.e., of grain radii between 5 nm and 1 mm and an optically thin and thick disk with a parameterized density distribution, we obtain the following results: in optically thin disk regions, the temperature spread can be as large as 63% and the relative grain surface below a certain temperature is lower than in the reference disk. With increasing optical depth, the difference in the midplane temperature and the relative grain surface below a certain temperature decreases. Furthermore, below 20 K, this fraction is higher for the reference disk than for the case of multiple grain radii, while it shows the opposite behavior for temperatures above this threshold. The thermal emission in the case of multiple grain radii at short wavelengths is stronger than for the reference disk. The freeze-out radius (snowline) is a function of grain radius, spanning a radial range between the coldest and warmest grain species of 30 AU.

  20. Cerebrospinal fluid lactate and pyruvate concentrations and their ratio.

    PubMed

    Zhang, Wan-Ming; Natowicz, Marvin R

    2013-05-01

    Determinations of cerebrospinal fluid (CSF) lactate and pyruvate concentrations and CSF lactate:pyruvate (L/P) ratios are important in several clinical settings, yet published normative data have significant limitations. We sought to determine a large dataset of stringently-defined normative data for CSF lactate and pyruvate concentrations and CSF L/P ratios. We evaluated data from 627 patients who had determinations of CSF lactate and/or CSF pyruvate from 2001 to 2011 at the Cleveland Clinic. Inclusion in the normal reference population required normal CSF cell counts, glucose and protein and routine serum chemistries and absence of progressive brain disorder, epilepsy, or seizure within 24h. Brain MRI, if done, showed no evidence of tumor, acute changes or basal ganglia abnormality. CSF cytology, CSF alanine and immunoglobulin levels, and oligoclonal band analysis were required to be normal, if done. Various inclusion/exclusion criteria were compared. 92 patients fulfilled inclusion/exclusion criteria for a reference population. The 95% central intervals (2.5%-97.5%) for CSF lactate and pyruvate levels were 1.01-2.09mM and 0.03-0.15mM, respectively, and 9.05-26.37 for CSF L/P. There were no significant gender-related differences of CSF lactate or pyruvate concentrations or of CSF L/P. Weak positive correlations between the concentration of CSF lactate or pyruvate and age were noted. Using stringent inclusion/exclusion criteria, we determined normative data for CSF lactate and pyruvate concentrations and CSF L/P ratios in a large, well-characterized reference population. Normalcy of routine CSF and blood analytes are the most important parameters in determining reference intervals for CSF lactate and pyruvate. Copyright © 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  1. Common View Time Transfer Using Worldwide GPS and DMA Monitor Stations

    NASA Technical Reports Server (NTRS)

    Reid, Wilson G.; McCaskill, Thomas B.; Oaks, Orville J.; Buisson, James A.; Warren, Hugh E.

    1996-01-01

    Analysis of the on-orbit Navstar clocks and the Global Positioning System (GPS) monitor station reference clocks is performed by the Naval Research Laboratory using both broadcast and postprocessed precise ephemerides. The precise ephemerides are produced by the Defense Mapping Agency (DMA) for each of the GPS space vehicles from pseudo-range measurements collected at five GPS and at five DMA monitor stations spaced around the world. Recently, DMA established an additional site co-located with the US Naval Observatory precise time site. The time reference for the new DMA site is the DoD Master Clock. Now, for the first time, it is possible to transfer time every 15 minutes via common view from the DoD Master Clock to the 11 GPS and DMA monitor stations. The estimated precision of a single common-view time transfer measurement taken over a 15-minute interval was between 1.4 and 2.7 nanoseconds. Using the measurements from all Navstar space vehicles in common view during the 15-minute interval, typically 3-7 space vehicles, improved the estimate of the precision to between 0.65 and 1.13 nanoseconds. The mean phase error obtained from closure of the time transfer around the world using the 11 monitor stations and the 25 space vehicle clocks over a period of 4 months had a magnitude of 31 picoseconds. Analysis of the low noise time transfer from the DoD Master Clock to each of the monitor stations yields not only the bias in the time of the reference clock, but also focuses attention on structure in the behaviour of the reference clock not previously seen. Furthermore, the time transfer provides a a uniformly sampled database of 15-minute measurements that make possible, for the first time, the direct and exhaustive computation of the frequency stability of the monitor station reference clocks. To lend perspective to the analysis, a summary is given of the discontinuities in phase and frequency that occurred in the reference clock at the Master Control Station during the period covered by the analysis.

  2. Computed tomography for occult fractures of the proximal femur, pelvis, and sacrum in clinical practice: single institution, dual-site experience.

    PubMed

    Mandell, Jacob C; Weaver, Michael J; Khurana, Bharti

    2018-06-01

    The purpose of this study was to evaluate the diagnostic performance of CT for assessment of occult fractures of the proximal femur, pelvis, and sacrum. A retrospective review was performed on patients who received a CT of the hip or pelvis for suspected occult fracture after negative or equivocal radiographs performed within 24 h. The official radiology report was utilized for the determination of CT findings and calculation of sensitivity and specificity. Surgical reports, MRI reports, and clinical follow-up were used as the standard of reference. Sensitivity and specificity were calculated with 95% confidence intervals. Seventy-four patients received CT of the hip or pelvis for clinical concern for occult fracture after negative or equivocal radiographs. By the reference standard, a total of 40 fractures were present in 25/74 (33.8%) patients, including 35 conservatively treated fractures of the greater trochanter, pelvis, and sacrum, and 5 operatively treated proximal femoral fractures. A total of 14/74 (18.9%) of patients had an MRI within 1 day of CT. MRI identified an operatively treated femoral neck fracture not seen on CT and an operatively treated intertrochanteric fracture, which CT described as a greater trochanteric fracture. There were two false negative conservatively treated pelvic fractures not seen on CT but diagnosed on MRI. On a per-patient basis, CT had an overall sensitivity of 88% (22/25; 95% confidence intervals 69-97%), specificity of 98% (48/49; 95% confidence intervals 89-100%), and negative predictive value of 94%. For the five operative proximal femoral fractures, the sensitivity of CT was 60% (3/5; 95% confidence intervals 15-95%), specificity was 99% (68/69; 95% confidence intervals 92-100%), and negative predictive value was 97%. In the clinical setting of suspected occult fracture, the sensitivity of clinical CT reports for detection of any type of fracture of the proximal femur, pelvis, or sacrum was 88%. For the small number of operatively treated proximal femoral fractures seen in the study, sensitivity of CT was 60% (3/5) and negative predictive value was 97%, although the relatively few patients needing fixation precludes statistical analysis.

  3. The algorithmic performance of J-Tpeak for drug safety clinical trial.

    PubMed

    Chien, Simon C; Gregg, Richard E

    The interval from J-point to T-wave peak (JTp) in ECG is a new biomarker able to identify drugs that prolong the QT interval but have different ion channel effects. If JTp is not prolonged, the prolonged QT may be associated with multi ion channel block that may have low torsade de pointes risk. From the automatic ECG measurement perspective, accurate and repeatable measurement of JTp involves different challenges than QT. We evaluated algorithm performance and JTp challenges using the Philips DXL diagnostic 12/16/18-lead algorithm. Measurement of JTp represents a different use model. Standard use of corrected QT interval is clinical risk assessment on patients with cardiac disease or suspicion of heart disease. Drug safety trials involve a very different population - young healthy subjects - who commonly have J-waves, notches and slurs. Drug effects include difficult and unusual morphology such as flat T-waves, gentle notches, and multiple T-wave peaks. The JTp initiative study provided ECGs collected from 22 young subjects (11 males and females) in randomized testing of dofetilide, quinidine, ranolazine, verapamil and placebo. We compare the JTp intervals between DXL algorithm and the FDA published measurements. The lead wise, vector-magnitude (VM), root-mean-square (RMS) and principal-component-analysis (PCA) representative beats were used to measure JTp and QT intervals. We also implemented four different methods for T peak detection for comparison. We found that JTp measurements were closer to the reference for combined leads RMS and PCA than individual leads. Differences in J-point location led to part of the JTp measurement difference because of the high prevalence of J-waves, notches and slurs. Larger differences were noted for drug effect causing multiple distinct T-wave peaks (Tp). The automated algorithm chooses the later peak while the reference was the earlier peak. Choosing among different algorithmic strategies in T peak measurement results in the tradeoff between stability and the accurate detection of calcium or sodium channel block. Measurement of JTp has different challenges than QT measurement. JTp measurement accuracy improved with combined leads RMS and PCA over lead II or V5. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Changes in sodium and uric acid concentrations in plasma during the menstrual cycle.

    PubMed

    Mira, M; Stewart, P M; Gebski, V; Llewellyn-Jones, D; Abraham, S F

    1984-03-01

    Hormonal changes during the menstrual cycle are well documented, but many other biochemical variables have not been studied. We find that in the luteal phase of the menstrual cycle the concentrations of sodium and uric acid are significantly lower. The changes may be of significance for the determination of the normal reference interval.

  5. Five-year risk of interval-invasive second breast cancer.

    PubMed

    Lee, Janie M; Buist, Diana S M; Houssami, Nehmat; Dowling, Emily C; Halpern, Elkan F; Gazelle, G Scott; Lehman, Constance D; Henderson, Louise M; Hubbard, Rebecca A

    2015-07-01

    Earlier detection of second breast cancers after primary breast cancer (PBC) treatment improves survival, yet mammography is less accurate in women with prior breast cancer. The purpose of this study was to examine women presenting clinically with second breast cancers after negative surveillance mammography (interval cancers), and to estimate the five-year risk of interval-invasive second cancers for women with varying risk profiles. We evaluated a prospective cohort of 15 114 women with 47 717 surveillance mammograms diagnosed with stage 0-II unilateral PBC from 1996 through 2008 at facilities in the Breast Cancer Surveillance Consortium. We used discrete time survival models to estimate the association between odds of an interval-invasive second breast cancer and candidate predictors, including demographic, PBC, and imaging characteristics. All statistical tests were two-sided. The cumulative incidence of second breast cancers after five years was 54.4 per 1000 women, with 325 surveillance-detected and 138 interval-invasive second breast cancers. The five-year risk of interval-invasive second cancer for women with referent category characteristics was 0.60%. For women with the most and least favorable profiles, the five-year risk ranged from 0.07% to 6.11%. Multivariable modeling identified grade II PBC (odds ratio [OR] = 1.95, 95% confidence interval [CI] = 1.15 to 3.31), treatment with lumpectomy without radiation (OR = 3.27, 95% CI = 1.91 to 5.62), interval PBC presentation (OR = 2.01, 95% CI 1.28 to 3.16), and heterogeneously dense breasts on mammography (OR = 1.54, 95% CI = 1.01 to 2.36) as independent predictors of interval-invasive second breast cancers. PBC diagnosis and treatment characteristics contribute to variation in subsequent-interval second breast cancer risk. Consideration of these factors may be useful in developing tailored post-treatment imaging surveillance plans. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  6. Five-Year Risk of Interval-Invasive Second Breast Cancer

    PubMed Central

    Buist, Diana S. M.; Houssami, Nehmat; Dowling, Emily C.; Halpern, Elkan F.; Gazelle, G. Scott; Lehman, Constance D.; Henderson, Louise M.; Hubbard, Rebecca A.

    2015-01-01

    Background: Earlier detection of second breast cancers after primary breast cancer (PBC) treatment improves survival, yet mammography is less accurate in women with prior breast cancer. The purpose of this study was to examine women presenting clinically with second breast cancers after negative surveillance mammography (interval cancers), and to estimate the five-year risk of interval-invasive second cancers for women with varying risk profiles. Methods: We evaluated a prospective cohort of 15 114 women with 47 717 surveillance mammograms diagnosed with stage 0-II unilateral PBC from 1996 through 2008 at facilities in the Breast Cancer Surveillance Consortium. We used discrete time survival models to estimate the association between odds of an interval-invasive second breast cancer and candidate predictors, including demographic, PBC, and imaging characteristics. All statistical tests were two-sided. Results: The cumulative incidence of second breast cancers after five years was 54.4 per 1000 women, with 325 surveillance-detected and 138 interval-invasive second breast cancers. The five-year risk of interval-invasive second cancer for women with referent category characteristics was 0.60%. For women with the most and least favorable profiles, the five-year risk ranged from 0.07% to 6.11%. Multivariable modeling identified grade II PBC (odds ratio [OR] = 1.95, 95% confidence interval [CI] = 1.15 to 3.31), treatment with lumpectomy without radiation (OR = 3.27, 95% CI = 1.91 to 5.62), interval PBC presentation (OR = 2.01, 95% CI 1.28 to 3.16), and heterogeneously dense breasts on mammography (OR = 1.54, 95% CI = 1.01 to 2.36) as independent predictors of interval-invasive second breast cancers. Conclusions: PBC diagnosis and treatment characteristics contribute to variation in subsequent-interval second breast cancer risk. Consideration of these factors may be useful in developing tailored post-treatment imaging surveillance plans. PMID:25904721

  7. Cyclogiro windmill

    DOEpatents

    Brulle, R.V.

    1981-09-03

    A cyclogiro windmill has a rotor provided with blades shaped in the configuration of symmetrical airfoils and actuators to pivot the blades about axes parallel to the axis of rotation for the rotor. The actuator for each blade constantly changes the rock angle for the blade, that is its angle with respect to a reference on the rotor, and this modulation is such that the blade in making a revolution around the axis of rotation for the rotor undergoes an interval of static operation wherein its angle of attack is for the most part constant and less than the static stall angle, a short interval where the blade flips to position in which its opposite surface is presented toward the free wind, a short interval of dynamic operation wherein the angle of attack exceeds the static stal angle, another interval of static operation at an angle of attack of essentially the same magnitude as before, another interval of blade flip, and another interval of dynamic operation. During the intervals of dynamic operation, the blades experience a significant increase in lift force without a corresponding increase in drag, so that a high lift-to-drag ratio develops. The blades during dynamic operation further develop strong vortices which are directed outwardly at the sides of the windmill stream tube, and this increases the width of the stream tube, causing a greater mass of air to flow through the rotor. The short intervals of operation under dynamic conditions enable the blades to extract more energy from the free wind than would be possible if the blade operated solely under static conditions, and this in turn renders the windmill more useful in moderate velocity winds as well as high velocity winds.

  8. Cyclogiro windmill

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brulle, R.V.

    1981-09-03

    A cyclogiro windmill has a rotor provided with blades shaped in the configuration of symmetrical airfoils and actuators to pivot the blades about axes parallel to the axis of rotation for the rotor. The actuator for each blade constantly changes the rock angle for the blade, that is its angle with respect to a reference on the rotor, and this modulation is such that the blade in making a revolution around the axis of rotation for the rotor undergoes an interval of static operation wherein its angle of attack is for the most part constant and less than the staticmore » stall angle, a short interval where the blade flips to position in which its opposite surface is presented toward the free wind, a short interval of dynamic operation wherein the angle of attack exceeds the static stal angle, another interval of static operation at an angle of attack of essentially the same magnitude as before, another interval of blade flip, and another interval of dynamic operation. During the intervals of dynamic operation, the blades experience a significant increase in lift force without a corresponding increase in drag, so that a high lift-to-drag ratio develops. The blades during dynamic operation further develop strong vortices which are directed outwardly at the sides of the windmill stream tube, and this increases the width of the stream tube, causing a greater mass of air to flow through the rotor. The short intervals of operation under dynamic conditions enable the blades to extract more energy from the free wind than would be possible if the blade operated solely under static conditions, and this in turn renders the windmill more useful in moderate velocity winds as well as high velocity winds.« less

  9. Standardization of the capillary electrophoresis procedures Capillarys® CDT and Minicap® CDT in comparison to the IFCC reference measurement procedure.

    PubMed

    Schellenberg, François; Humeau, Camille

    2017-06-01

    CDT is at present the most relevant routinely available biological marker of alcohol use and is widely used for screening and monitoring of patients. The lack of standardization leads to specific reference intervals for each procedure. The IFCC working group devoted to CDT demonstrated that the standardization is possible using calibrators assigned to the reference measurement procedure. In this study, we compare the capillary electrophoresis (CE) techniques Capillarys® CDT and Minicap® CDT (Sebia, Lisses, France) to the reference procedure before and after standardization in 126 samples covering the range of CDT measurement. Both capillary electrophoresis procedures show a high correlation (r=0,997) with the reference procedure and the concordance correlation coefficient evaluated according to Mc Bride is "almost perfect" (>0.997 for both CE procedures). The number of results with a relative difference higher than the acceptable difference limit is only 1 for Capillarys® CDT and 5 for Minicap® CDT. These results demonstrate the efficiency of the standardization of CDT measurements for both CE techniques from Sebia, achieved using calibrators assigned to the reference measurement procedure.

  10. Evaluating the influential priority of the factors on insurance loss of public transit

    PubMed Central

    Su, Yongmin; Chen, Xinqiang

    2018-01-01

    Understanding correlation between influential factors and insurance losses is beneficial for insurers to accurately price and modify the bonus-malus system. Although there have been a certain number of achievements in insurance losses and claims modeling, limited efforts focus on exploring the relative role of accidents characteristics in insurance losses. The primary objective of this study is to evaluate the influential priority of transit accidents attributes, such as the time, location and type of accidents. Based on the dataset from Washington State Transit Insurance Pool (WSTIP) in USA, we implement several key algorithms to achieve the objectives. First, K-means algorithm contributes to cluster the insurance loss data into 6 intervals; second, Grey Relational Analysis (GCA) model is applied to calculate grey relational grades of the influential factors in each interval; in addition, we implement Naive Bayes model to compute the posterior probability of factors values falling in each interval. The results show that the time, location and type of accidents significantly influence the insurance loss in the first five intervals, but their grey relational grades show no significantly difference. In the last interval which represents the highest insurance loss, the grey relational grade of the time is significant higher than that of the location and type of accidents. For each value of the time and location, the insurance loss most likely falls in the first and second intervals which refers to the lower loss. However, for accidents between buses and non-motorized road users, the probability of insurance loss falling in the interval 6 tends to be highest. PMID:29298337

  11. Evaluating the influential priority of the factors on insurance loss of public transit.

    PubMed

    Zhang, Wenhui; Su, Yongmin; Ke, Ruimin; Chen, Xinqiang

    2018-01-01

    Understanding correlation between influential factors and insurance losses is beneficial for insurers to accurately price and modify the bonus-malus system. Although there have been a certain number of achievements in insurance losses and claims modeling, limited efforts focus on exploring the relative role of accidents characteristics in insurance losses. The primary objective of this study is to evaluate the influential priority of transit accidents attributes, such as the time, location and type of accidents. Based on the dataset from Washington State Transit Insurance Pool (WSTIP) in USA, we implement several key algorithms to achieve the objectives. First, K-means algorithm contributes to cluster the insurance loss data into 6 intervals; second, Grey Relational Analysis (GCA) model is applied to calculate grey relational grades of the influential factors in each interval; in addition, we implement Naive Bayes model to compute the posterior probability of factors values falling in each interval. The results show that the time, location and type of accidents significantly influence the insurance loss in the first five intervals, but their grey relational grades show no significantly difference. In the last interval which represents the highest insurance loss, the grey relational grade of the time is significant higher than that of the location and type of accidents. For each value of the time and location, the insurance loss most likely falls in the first and second intervals which refers to the lower loss. However, for accidents between buses and non-motorized road users, the probability of insurance loss falling in the interval 6 tends to be highest.

  12. USGS46 Greenland ice core water – A new isotopic reference material for δ2H and δ18O measurements of water

    USGS Publications Warehouse

    Coplen, Tyler B.; Qi, Haiping; Tarbox, Lauren V.; Lorenz, Jennifer M.; Buck, Bryan

    2015-01-01

    Ice core from Greenland was melted, filtered, homogenised, loaded into glass ampoules, sealed, autoclaved to eliminate biological activity, and calibrated by dual-inlet isotope-ratio mass spectrometry. This isotopic reference material (RM), USGS46, is intended as one of two secondary isotopic reference waters for daily normalisation of stable hydrogen (δ2H) and stable oxygen (δ18O) isotopic analysis of water with a mass spectrometer or a laser absorption spectrometer. The measured δ2H and δ18O values of this reference water were −235.8 ± 0.7‰ and −29.80 ± 0.03‰, respectively, relative to VSMOW on scales normalised such that the δ2H and δ18O values of SLAP reference water are, respectively, −428 and −55.5‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95-percent probability of encompassing the true value. This reference water is available in cases containing 144 glass ampoules that are filled with either 4 ml or 5 ml of water per ampoule.

  13. Effect of Extended 30 μg Ethinyl Estradiol with Continuous Low-Dose Ethinyl Estradiol and Cyclic 20 μg Ethinyl Estradiol Oral Contraception on Adolescent Bone Density: A Randomized Trial.

    PubMed

    Gersten, Janet; Hsieh, Jennifer; Weiss, Herman; Ricciotti, Nancy A

    2016-12-01

    To compare changes in lumbar spine bone mineral density after 12 months of a 91-day extended regimen or 28-day combined oral contraceptive with those in a healthy reference group not using hormonal contraceptives. Phase 2, multicenter, open-label, randomized, controlled study. Forty-five academic centers, clinical research centers, and community practices in the United States. Eight hundred twenty-nine postmenarcheal adolescent girls aged 12-18 years. Adolescents were randomly assigned to 91-day levonorgestrel (LNG)/ethinyl estradiol (EE) extended regimen (84 days of LNG 150 μg/EE 30 μg with 7 days of EE 10 μg [LNG/EE extended regimen]) or 28 days of LNG/EE (21 days of LNG 100 μg/EE 20 μg with 7 days of placebo [LNG/EE 21/7]) for 12 months. A reference group not seeking hormonal contraception was also evaluated. The primary end point was mean percent change in lumbar spine bone mineral density measured using dual-energy x-ray absorptiometry. Of 1361 adolescents randomized/enrolled, 829 were included in the primary analysis. Mean changes in lumbar spine bone mineral density were +2.26% with LNG/EE extended regimen, +1.45% with LNG/EE 21/7, and +2.50% in the reference group. Noninferiority of the LNG/EE extended regimen compared with the reference group was shown. A statistically significant treatment difference was found between LNG/EE 21/7 and the reference group (1.05%; 95% confidence interval, 0.61%-1.49%) but not between LNG/EE extended regimen and the reference group (0.23%; 95% confidence interval, -0.20% to 0.67%). No new safety signals were noted. Compared with the reference group, bone accrual was statistically significantly lower among LNG/EE 21/7 users but not among LNG/EE 30-μg extended regimen users. Additional research is needed to clarify the clinical relevance of these findings. Copyright © 2016 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  14. Biscayne aquifer drinking water (USGS45): a new isotopic reference material for δ2H and δ18O measurements of water

    USGS Publications Warehouse

    Lorenz, Jennifer M.; Tarbox, Lauren V.; Buck, Bryan; Qi, Haiping; Coplen, Tyler B.

    2014-01-01

    RATIONALE As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from drinking water collected from the Biscayne aquifer in Ft. Lauderdale, Florida. METHODS This isotopic reference water was filtered, homogenized, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and measured by dual-inlet isotope-ratio mass spectrometry. This reference material is available by the case of 144 glass ampoules containing either 4 mL or 5 mL of water in each ampoule. RESULTS The δ2H and δ18O values of this reference material are –10.3 ± 0.4 ‰ and –2.238 ± 0.011 ‰, respectively, relative to VSMOW, on scales normalized such that the δ2H and δ18O values of SLAP reference water are, respectively, –428 and –55.5 ‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95 % probability of encompassing the true value. CONCLUSIONS This isotopic reference material, designated as USGS45, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer. 

  15. Plasma exogenous creatinine clearance in clinically healthy cats: comparison with urinary exogenous creatinine clearance, tentative reference intervals and indexation to bodyweight.

    PubMed

    Reynolds, B S; Massal, M R; Nguyen, P; Grégoire, L L; Périgaud, A E; Concordet, D; Biourge, V; Lefebvre, H P

    2014-10-01

    Glomerular filtration rate (GFR) is considered to be the best indicator of overall kidney function. The major objectives of this study were to compare plasma exogenous creatinine clearance (PECC) with a reference method, to establish reference intervals (RIs) for PECC and to assess the effects of indexation of GFR to bodyweight (BW) in cats. PECC was compared with urinary clearance of exogenous creatinine (UECC) in six clinically healthy domestic shorthair cats (experiment 1). Tentative RIs were determined according to current guidelines and the effects of indexation to BW and of covariables on GFR were assessed in 43 clinically healthy cats of various breeds (experiment 2). PECC was 15% higher than UECC (P <0.01), but the two estimates were strongly correlated (r(2)=0.97, P = 0.001). RIs for PECC were 6.4-21.3 mL/min or 1.2-4.9 mL/min/kg. The absolute (i.e. non-indexed) GFR value was not dependent on BW. Thus, indexation of GFR to BW in cats would not standardize the GFR value, but could introduce bias in clinical interpretation. Significant effects of breed, plasma protein concentration and plasma albumin concentration on GFR were demonstrated. Plasma concentrations of urea and creatinine, when assessed separately, were also weakly correlated with GFR in healthy cats. These combined findings contribute to a better understanding of renal function assessment in cats. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Diagnostic performance of EUS in predicting advanced cancer among patients with Barrett's esophagus and high-grade dysplasia/early adenocarcinoma: systematic review and meta-analysis.

    PubMed

    Qumseya, Bashar J; Brown, Jessica; Abraham, Merna; White, Donna; Wolfsen, Herbert; Gupta, Neil; Vennalaganti, Prashanth; Sharma, Prateek; Wallace, Michael B

    2015-04-01

    The role of EUS among patients with Barrett's esophagus (BE) with high-grade dysplasia (HGD) or suspected mucosal carcinoma is controversial. To define the role of EUS in detecting advanced disease among patients with BE. Systematic review and meta-analysis. MEDLINE, Embase, Web of Science, and Cochrane Central databases. Patients with BE and HGD or esophageal adenocarcinoma (EAC) who were referred for endoscopic evaluation and underwent EUS. EUS. Pooled proportion of patients with advanced EAC identified by EUS among patients with BE who are referred for HGD or EAC (with or without visible lesions). Forest plots were used to contrast effect sizes in each of the studies and random effect models when tests of heterogeneity were significant (I(2) > 50% or P < .1 for the Q statistic). Of 1278 articles, 47 were reviewed in full text, and 11 articles met the inclusion criteria, including a total of 656 patients. Based on a random-effects model, the proportion of patients with advanced disease detected on EUS was 14% (95% confidence interval, 8%-22%; P < .0001). In a subanalysis, the pooled proportion of patients with advanced disease on EUS in the absence of nodules was 4% (95% confidence interval, 2%-6%, P < .0001). Significant heterogeneity among studies. EUS will result in a change in the therapeutic approach among in a significant minority of patients with BE who are referred for HGD or EAC. Copyright © 2015. Published by Elsevier Inc.

  17. Establishing reference intervals for electrolytes in newborns and infants using direct ISE analyzer

    PubMed Central

    2013-01-01

    Background To generate clinically applicable reference intervals (RIs) for commonly requested electrolytes in Ethiopian newborns and infants that can help in early detection, close monitoring and correction of electrolyte abnormalities. Cord blood (from newborns, n = 60) and venous blood samples (from infants, n = 57) were collected and analyzed using direct ISE analyzer, AVL (9181). MedCalc® software was applied to determine the robust upper and lower end points covering 95% of the reference values of each electrolyte with respective 90% CIs. Findings This is an extension report of our recent study; and hence is resulted from the same data source. The level of Na+ and K+ showed difference in newborns and infants even though combined RIs were suggested by the Haris and Boyd rule as 126–143 mmol/l and 4.0-7.9 mmol/l respectively. However, Cl- values failed to show such a difference and thus a combined RI was determined to be 100–111 mmol/l. Almost all maternal, neonatal and infantile factors were not able to affect the values of the electrolytes. Conclusion Combined RIs are suggested for the interpretation of electrolyte values in newborns and infants without taking the effect of maternal, neonatal and infantile factors into account. Since the RIs were different from previously reported values, it will be appropriate to apply such RIs for the interpretation of electrolyte values in Ethiopian pediatric population. PMID:23688032

  18. Analysis of serum and cerebrospinal fluid in clinically normal adult miniature donkeys.

    PubMed

    Mozaffari, A A; Samadieh, H

    2013-09-01

    To establish reference intervals for serum and cerebrospinal fluid (CSF) parameters in clinically healthy adult miniature donkeys. Experiments were conducted on 10 female and 10 male clinically normal adult miniature donkeys, randomly selected from five herds. Lumbosacral CSF collection was performed with the sedated donkey in the standing position. Cell analysis was performed immediately after the samples were collected. Blood samples were obtained from the jugular vein immediately after CSF sample collection. Sodium, potassium, glucose, urea nitrogen, total protein, calcium, chloride, phosphorous and magnesium concentrations were measured in CSF and serum samples. A paired t-test was used to compare mean values between female and male donkeys. The CSF was uniformly clear, colourless and free from flocculent material, with a specific gravity of 1.002. The range of total nucleated cell counts was 2-4 cells/μL. The differential white cell count comprised only small lymphocytes. No erythrocytes or polymorphonuclear cells were observed on cytological examination. Reference values were obtained for biochemical analysis of serum and CSF. Gender had no effect on any variables measured in serum or CSF (p>0.05). CSF analysis can provide important information in addition to that gained by clinical examination. CSF analysis has not previously been performed in miniature donkeys; this is the first report on the subject. In the present study, reference intervals for total nucleated cell count, total protein, glucose, urea nitrogen, sodium, potassium, chloride, calcium, phosphorous and magnesium concentrations of serum and CSF were determined for male and female miniature donkeys.

  19. Cancer mortality in Minamata disease patients exposed to methylmercury through fish diet.

    PubMed

    Kinjo, Y; Akiba, S; Yamaguchi, N; Mizuno, S; Watanabe, S; Wakamiya, J; Futatsuka, M; Kato, H

    1996-09-01

    We report here a historical cohort study on cancer mortality among Minamata disease (MD) patients (n = 1,351) in Kagoshima and Kumamoto Prefectures of Japan. Taking into account their living area, sex, age and fish eating habits, the residents (n = 5,667; 40 years of age or over at 1966) living in coastal areas of Kagoshima, who consumed fish daily, were selected as a reference group from the six-prefecture cohort study conducted by Hirayama et al. The observation periods of the MD patients and of the reference group were from 1973 to 1984 and from 1970 to 1981, respectively. Survival analysis using the Poisson regression model was applied for comparison of mortality between the MD patients and the reference group. No excess of relative risk (RR) adjusted for attained age, sex and follow-up period was observed for mortality from all causes, all cancers, and non-cancers combined. Analysis of site-specific cancers showed a statistically significant decrease in mortality from stomach cancer among MD patients (RR, 0.49; 95% confidence interval, 0.26-0.94). In addition, a statistically significant eight-fold excess risk, based on 5 observed deaths, was noted for mortality from leukemia (RR, 8.35; 95 % confidence interval 1.61-43.3). It is, however, unlikely for these observed risks to be derived from methylmercury exposure only. Further studies are needed to understand the mechanisms involved in the observed risks among MD patients.

  20. Diagnosis and treatment of chronic lymphocytic leukemia in a bat-eared fox (Otocyon megalotis).

    PubMed

    Nevitt, Benjamin N; Langan, Jennifer N; Adkesson, Michael J; Landolfi, Jennifer A; Wilson, Rand

    2014-12-15

    Severe lymphocytosis and leukocytosis were detected during examination of a 10-year-old sexually intact male bat-eared fox (Otocyon megalotis) with regionally extensive alopecia. A CBC revealed severe leukocytosis (39,100 leukocytes/μL) and marked lymphocytosis (90%). A blood smear consisted predominantly of intermediate-sized lymphocytes and few large lymphocytes, with mild to moderate nuclear atypia. These findings were highly suggestive of chronic lymphocytic leukemia (CLL). Cytologic evaluation of bone marrow aspirates revealed no evidence of overt malignancy, with 10% of all cells identified as small to intermediate-sized mature lymphocytes. Treatment with chlorambucil and prednisone administered orally over a 1.8-year period decreased the leukocyte and lymphocyte counts to within reference intervals with no adverse effects. Although repeated flow cytometry revealed evidence of residual disease, the fox remained free of clinical disease, and WBC counts were within reference intervals for this species. At 22 months after initial evaluation, the fox was euthanized because of debilitating arthritis. No evidence of CLL was detected grossly or histologically during necropsy. To the authors' knowledge, this was the first report of CLL in a bat-eared fox and first successful treatment in a nondomestic carnivore. Treatment in accordance with a chemotherapeutic protocol successfully resolved the leukocytosis and lymphocytosis with no serious adverse effects. Description of this fox and the treatment protocol should provide a valuable reference for future cases in this and other nondomestic canine species.

  1. An Indoor Positioning Technique Based on a Feed-Forward Artificial Neural Network Using Levenberg-Marquardt Learning Method

    NASA Astrophysics Data System (ADS)

    Pahlavani, P.; Gholami, A.; Azimi, S.

    2017-09-01

    This paper presents an indoor positioning technique based on a multi-layer feed-forward (MLFF) artificial neural networks (ANN). Most of the indoor received signal strength (RSS)-based WLAN positioning systems use the fingerprinting technique that can be divided into two phases: the offline (calibration) phase and the online (estimation) phase. In this paper, RSSs were collected for all references points in four directions and two periods of time (Morning and Evening). Hence, RSS readings were sampled at a regular time interval and specific orientation at each reference point. The proposed ANN based model used Levenberg-Marquardt algorithm for learning and fitting the network to the training data. This RSS readings in all references points and the known position of these references points was prepared for training phase of the proposed MLFF neural network. Eventually, the average positioning error for this network using 30% check and validation data was computed approximately 2.20 meter.

  2. Mapping the literature of nursing informatics.

    PubMed

    Guenther, Johanna T

    2006-04-01

    This study was part of the Medical Library Association's Nursing and Allied Health Resources Section's project to map the nursing literature. It identified core journals in nursing informatics and the journals referenced in them and analyzed coverage of those journals in selected indexes. Five core journals were chosen and analyzed for 1996, 1997, and 1998. The references in the core journal articles were examined for type and number of formats cited during the selected time period. Bradford's Law of Scattering divided the journals into frequency zones. The time interval, 1990 to 1998, produced 71% of the references. Internet references could not be tracked by date before 1990. Twelve journals were the most productive, 119 journals were somewhat productive, and 897 journals were the least productive. Journal of the American Medical Informatics Association was the most prolific core journal. The 1998 journal references were compared in CINAHL, PubMed/MEDLINE, Science Citation Index, and OCLC Article First. PubMed/MEDLINE had the highest indexing score.

  3. Mapping the literature of nursing informatics

    PubMed Central

    Guenther, Johanna T.

    2006-01-01

    Objective: This study was part of the Medical Library Association's Nursing and Allied Health Resources Section's project to map the nursing literature. It identified core journals in nursing informatics and the journals referenced in them and analyzed coverage of those journals in selected indexes. Method: Five core journals were chosen and analyzed for 1996, 1997, and 1998. The references in the core journal articles were examined for type and number of formats cited during the selected time period. Bradford's Law of Scattering divided the journals into frequency zones. Results: The time interval, 1990 to 1998, produced 71% of the references. Internet references could not be tracked by date before 1990. Twelve journals were the most productive, 119 journals were somewhat productive, and 897 journals were the least productive. Journal of the American Medical Informatics Association was the most prolific core journal. The 1998 journal references were compared in CINAHL, PubMed/MEDLINE, Science Citation Index, and OCLC Article First. PubMed/MEDLINE had the highest indexing score. PMID:16710469

  4. [Reference values for lead levels in blood for the urban population].

    PubMed

    Paolielo, M M; Gutierrez, P R; Turini, C A; Matsuo, T; Mezzaroba, L; Barbosa, D S; Alvarenga, A L; Carvalho, S R; Figueiroa, G A; Leite, V G; Gutierrez, A C; Nogueira, K B; Inamine, W A; Zavatti, A M

    1997-04-01

    The lead reference values for blood used in Brazil come from studies conducted in other countries, where socioeconomic, clinical, nutritional and occupational conditions are significantly different. In order to guarantee an accurate biomonitoring of the population which is occupationally exposed to lead, a major health concern of the studied community, reference values for individuals who are not occupationally exposed and who live in the southern region of the city were established. The sample was composed of 206 subjects of at least 15 years of age. Various strategies were employed to assure good-quality sampling. Subjects who presented values outside clinical or laboratory norms were excluded, as well as those whose specific activities might interfere with the results. Lead reference values for blood were found to be from 2.40 to 16.6 micrograms.dL-1, obtained by the interval x +/- 2s (where x is the mean and s is the standard deviation form observed values) and the median was 7.9 micrograms.dL-1.

  5. Estimating equivalence with quantile regression

    USGS Publications Warehouse

    Cade, B.S.

    2011-01-01

    Equivalence testing and corresponding confidence interval estimates are used to provide more enlightened statistical statements about parameter estimates by relating them to intervals of effect sizes deemed to be of scientific or practical importance rather than just to an effect size of zero. Equivalence tests and confidence interval estimates are based on a null hypothesis that a parameter estimate is either outside (inequivalence hypothesis) or inside (equivalence hypothesis) an equivalence region, depending on the question of interest and assignment of risk. The former approach, often referred to as bioequivalence testing, is often used in regulatory settings because it reverses the burden of proof compared to a standard test of significance, following a precautionary principle for environmental protection. Unfortunately, many applications of equivalence testing focus on establishing average equivalence by estimating differences in means of distributions that do not have homogeneous variances. I discuss how to compare equivalence across quantiles of distributions using confidence intervals on quantile regression estimates that detect differences in heterogeneous distributions missed by focusing on means. I used one-tailed confidence intervals based on inequivalence hypotheses in a two-group treatment-control design for estimating bioequivalence of arsenic concentrations in soils at an old ammunition testing site and bioequivalence of vegetation biomass at a reclaimed mining site. Two-tailed confidence intervals based both on inequivalence and equivalence hypotheses were used to examine quantile equivalence for negligible trends over time for a continuous exponential model of amphibian abundance. ?? 2011 by the Ecological Society of America.

  6. Forensic use of the Greulich and Pyle atlas: prediction intervals and relevance.

    PubMed

    Chaumoitre, K; Saliba-Serre, B; Adalian, P; Signoli, M; Leonetti, G; Panuel, M

    2017-03-01

    The Greulich and Pyle (GP) atlas is one of the most frequently used methods of bone age (BA) estimation. Our aim is to assess its accuracy and to calculate the prediction intervals at 95% for forensic use. The study was conducted on a multi-ethnic sample of 2614 individuals (1423 boys and 1191 girls) referred to the university hospital of Marseille (France) for simple injuries. Hand radiographs were analysed using the GP atlas. Reliability of GP atlas and agreement between BA and chronological age (CA) were assessed and prediction intervals at 95% were calculated. The repeatability was excellent and the reproducibility was good. Pearson's linear correlation coefficient between CA and BA was 0.983. The mean difference between BA and CA was -0.18 years (boys) and 0.06 years (girls). The prediction interval at 95% for CA was given for each GP category and ranged between 1.2 and more than 4.5 years. The GP atlas is a reproducible and repeatable method that is still accurate for the present population, with a high correlation between BA and CA. The prediction intervals at 95% are wide, reflecting individual variability, and should be known when the method is used in forensic cases. • The GP atlas is still accurate at the present time. • There is a high correlation between bone age and chronological age. • Individual variability must be known when GP is used in forensic cases. • Prediction intervals (95%) are large; around 4 years after 10 year olds.

  7. Serial binary interval ratios improve rhythm reproduction.

    PubMed

    Wu, Xiang; Westanmo, Anders; Zhou, Liang; Pan, Junhao

    2013-01-01

    Musical rhythm perception is a natural human ability that involves complex cognitive processes. Rhythm refers to the organization of events in time, and musical rhythms have an underlying hierarchical metrical structure. The metrical structure induces the feeling of a beat and the extent to which a rhythm induces the feeling of a beat is referred to as its metrical strength. Binary ratios are the most frequent interval ratio in musical rhythms. Rhythms with hierarchical binary ratios are better discriminated and reproduced than rhythms with hierarchical non-binary ratios. However, it remains unclear whether a superiority of serial binary over non-binary ratios in rhythm perception and reproduction exists. In addition, how different types of serial ratios influence the metrical strength of rhythms remains to be elucidated. The present study investigated serial binary vs. non-binary ratios in a reproduction task. Rhythms formed with exclusively binary (1:2:4:8), non-binary integer (1:3:5:6), and non-integer (1:2.3:5.3:6.4) ratios were examined within a constant meter. The results showed that the 1:2:4:8 rhythm type was more accurately reproduced than the 1:3:5:6 and 1:2.3:5.3:6.4 rhythm types, and the 1:2.3:5.3:6.4 rhythm type was more accurately reproduced than the 1:3:5:6 rhythm type. Further analyses showed that reproduction performance was better predicted by the distribution pattern of event occurrences within an inter-beat interval, than by the coincidence of events with beats, or the magnitude and complexity of interval ratios. Whereas rhythm theories and empirical data emphasize the role of the coincidence of events with beats in determining metrical strength and predicting rhythm performance, the present results suggest that rhythm processing may be better understood when the distribution pattern of event occurrences is taken into account. These results provide new insights into the mechanisms underlining musical rhythm perception.

  8. Serial binary interval ratios improve rhythm reproduction

    PubMed Central

    Wu, Xiang; Westanmo, Anders; Zhou, Liang; Pan, Junhao

    2013-01-01

    Musical rhythm perception is a natural human ability that involves complex cognitive processes. Rhythm refers to the organization of events in time, and musical rhythms have an underlying hierarchical metrical structure. The metrical structure induces the feeling of a beat and the extent to which a rhythm induces the feeling of a beat is referred to as its metrical strength. Binary ratios are the most frequent interval ratio in musical rhythms. Rhythms with hierarchical binary ratios are better discriminated and reproduced than rhythms with hierarchical non-binary ratios. However, it remains unclear whether a superiority of serial binary over non-binary ratios in rhythm perception and reproduction exists. In addition, how different types of serial ratios influence the metrical strength of rhythms remains to be elucidated. The present study investigated serial binary vs. non-binary ratios in a reproduction task. Rhythms formed with exclusively binary (1:2:4:8), non-binary integer (1:3:5:6), and non-integer (1:2.3:5.3:6.4) ratios were examined within a constant meter. The results showed that the 1:2:4:8 rhythm type was more accurately reproduced than the 1:3:5:6 and 1:2.3:5.3:6.4 rhythm types, and the 1:2.3:5.3:6.4 rhythm type was more accurately reproduced than the 1:3:5:6 rhythm type. Further analyses showed that reproduction performance was better predicted by the distribution pattern of event occurrences within an inter-beat interval, than by the coincidence of events with beats, or the magnitude and complexity of interval ratios. Whereas rhythm theories and empirical data emphasize the role of the coincidence of events with beats in determining metrical strength and predicting rhythm performance, the present results suggest that rhythm processing may be better understood when the distribution pattern of event occurrences is taken into account. These results provide new insights into the mechanisms underlining musical rhythm perception. PMID:23964258

  9. Understanding the Global Distribution of Monsoon Depressions

    DTIC Science & Technology

    2013-09-30

    1.0 PVU interval) is shown for reference. Top left panel shows the Eulerian rate of change of PV, top right shows the diabatic PV tendency, bottom...left shows the horizontal advective tendency, and bottom right shows the sum of the diabatic and total advective tendencies. The vertical advective tendency is not plotted, but is of similar amplitude to the diabatic tendency.

  10. Testing and Interval Estimation in a Change-Point Model Allowing at Most One Change.

    DTIC Science & Technology

    1987-07-01

    we refer to Krishnaiah and Miao (1986), Cs’Orgo and Horvath (1986) for a detailed survey of this subject. The methodology of the present paper is... KRISHNAIAH , P, R., MIAO, B. (1986). Review About Estimates of Change Point, to Appear in Hman dbook o-f 3’a-stis, Vol, 7 [ 6] QUALLS, C-, WATANABE, H

  11. 78 FR 32498 - Self-Regulatory Organizations; NASDAQ OMX PHLX LLC; Notice of Filing and Immediate Effectiveness...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-30

    ... Change Relating to $0.50 and $1 Strike Price Intervals for Classes in the Short Term Option Series... amend Rule 1012 (Series of Options Open for Trading) and Rule 1101A (Terms of Option Contracts) to give... Term Option Series Program (referred to as a ``Related non-Short Term Option series''), for the Related...

  12. Toward a national early warning system for forest disturbances using remotely sensed canopy phenology

    Treesearch

    William W. Hargrove; Joseph P. Spruce; Gerald E. Gasser; Forrest M. Hoffman

    2009-01-01

    Imagine a national system with the ability to quickly identify forested areas under attack from insects or disease. Such an early warning system might minimize surprises such as the explosion of caterpillars referred to in the quotation above. Moderate resolution (ca. 500m) remote sensing repeated at frequent (ca. weekly) intervals could power such a monitoring system...

  13. Sleep Can Reduce the Testing Effect: It Enhances Recall of Restudied Items but Can Leave Recall of Retrieved Items Unaffected

    ERIC Educational Resources Information Center

    Bäuml, Karl-Heinz T.; Holterman, Christoph; Abel, Magdalena

    2014-01-01

    The testing effect refers to the finding that retrieval practice in comparison to restudy of previously encoded contents can improve memory performance and reduce time-dependent forgetting. Naturally, long retention intervals include both wake and sleep delay, which can influence memory contents differently. In fact, sleep immediately after…

  14. 40 CFR 1065.202 - Data updating, recording, and control.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... means. § 1065.514, § 1065.530 Steady-state and ramped-modal duty cycle reference and feedback speeds and... mean value per test interval. § 1065.530, § 1065.545 Diluted exhaust flow rate from a CVS with a heat exchanger upstream of the flow measurement N/A 1 Hz. § 1065.530, § 1065.545 Diluted exhaust flow rate from a...

  15. Extrapolar climate reversal during the last deglaciation.

    PubMed

    Asmerom, Yemane; Polyak, Victor J; Lachniet, Matthew S

    2017-08-02

    Large ocean-atmosphere and hydroclimate changes occurred during the last deglaciation, although the interplay between these changes remains ambiguous. Here, we present a speleothem-based high resolution record of Northern Hemisphere atmospheric temperature driven polar jet variability, which matches the Greenland ice core records for the most of the last glacial period, except during the last deglaciation. Our data, combined with data from across the globe, show a dramatic climate reversal during the last deglaciation, which we refer to as the Extrapolar Climate Reversal (ECR). This is the most prominent feature in most tropical and subtropical hydroclimate proxies. The initiation of the ECR coincides with the rapid rise in CO 2 , in part attributed to upwelling in the Southern Ocean and the near collapse of the Atlantic Meridional Overturning Circulation. We attribute the ECR to upwelling of cold deep waters from the Southern Ocean. This is supported by a variety of proxies showing the incursion of deep Southern Ocean waters into the tropics and subtropics. Regional climate variability across the extropolar regions during the interval previously referred to as the "Mystery Interval" can now be explained in the context of the ECR event.

  16. [The alpha-fetoprotein in prognosis of survival of and functional rehabilitation of patients with ischemic stroke].

    PubMed

    Arkhipkin, A A; Liang, O V; Kochetov, A G

    2014-10-01

    The study was carried out to determine the prognostic value of alpha-fetoprotein in development of lethal outcome and degree of functional rehabilitation of patients with ischemic stroke. The sampling included 216 patients in acute period of ischemic stroke. At the first day of development of disease they were measured the level of human alpha-fetoprotein. At the second day of disease patients were evaluated the degree of functional rehabilitation and the rate of lethal outcomes was calculated. Previously, the reference interval for alpha-fetoprotein was calculated according the guidelines of the International federation of clinical chemistry and national standard. The reference interval amounted to 0.59-3.78 mE/l. The study results demonstrated that low level of alpha-fetoprotein is related to higher risk of lethal outcome (SE=1.7, p=0.012). The increasing of level of alpha-fetoprotein over mentioned threshold value statistically significant increases probability of survival of patients. The further increasing more than 2.28 mE/l is related to subsequent good functional rehabilitation according the modifies Rankine scale (SE=1.4, p=0.001) and Barthel index (SE=1.49, p<0.001).

  17. Efficacy of a Clinic-Based Safer Sex Program for Human Immunodeficiency Virus-Uninfected and Human Immunodeficiency Virus-Infected Young Black Men Who Have Sex With Men: A Randomized Controlled Trial.

    PubMed

    Crosby, Richard A; Mena, Leandro; Salazar, Laura F; Hardin, James W; Brown, Tim; Vickers Smith, Rachel

    2018-03-01

    To test the efficacy of a single-session, clinic-based intervention designed to promote condom use among young black men who have sex with men (YBMSM). Six hundred YBMSM were enrolled in a randomized controlled trial, using a 12-month observation period. An intent-to-treat analysis was performed, with multiple imputation for missing data. Compared with the reference group, human immunodeficiency virus (HIV)-infected men in the intervention group had 64% greater odds of reporting consistent condom use for anal receptive sex over 12 months (estimated odds ratio, 1.64; 95% confidence interval, 1.23-2.17, P = 0.001). Also, compared with the reference group, HIV-uninfected men in the intervention group had more than twice the odds of reporting consistent condom use for anal receptive sex over 12 months (estimated odds ratio, 2.14; 95% confidence interval, 1.74-2.63, P < 0.001). Significant intervention effects relative to incident sexually transmitted diseases were not observed. A single-session, clinic-based, intervention may help protect HIV-uninfected YBMSM against HIV acquisition and HIV-infected YBMSM from transmitting the virus to insertive partners.

  18. Rate of penicillin killing of Staphylococcus aureus and Autobac 1 susceptibility test results.

    PubMed Central

    Harris, J A; Furtado, D

    1982-01-01

    A clinical isolate of Staphylococcus aureus interpreted as resistant to penicillin by the Autobac 1 susceptibility testing method (i.e., light-scattering index of 0.77) was found to be susceptible to penicillin by both the disk diffusion and broth dilution techniques. The growth rate of the clinical isolate during a 4-h incubation interval was similar to that of a known sensitive reference strain (S. aureus ATCC 25923) used as a control organism for the Autobac test. The bactericidal effect of penicillin was evaluated by measuring the rate of killing over a 4-h interval. The percentages of organisms surviving exposure to 5.0 or 2.5 U of penicillin G per ml (number of organisms recovered at 3 h/number of organisms introduced as inoculum) were 68 and 76%, respectively, for the clinical isolate and 15 and 21%, respectively, for the reference strain. After 24 h of incubation, penicillin was bactericidal for both strains. The need to increase the time of incubation for those S. aureus isolates resistant to penicillin after 3 h of standard incubation time in the Autobac system is discussed. PMID:7068821

  19. Calibration method helps in seismic velocity interpretation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guzman, C.E.; Davenport, H.A.; Wilhelm, R.

    1997-11-03

    Acoustic velocities derived from seismic reflection data, when properly calibrated to subsurface measurements, help interpreters make pure velocity predictions. A method of calibrating seismic to measured velocities has improved interpretation of subsurface features in the Gulf of Mexico. In this method, the interpreter in essence creates a kind of gauge. Properly calibrated, the gauge enables the interpreter to match predicted velocities to velocities measured at wells. Slow-velocity zones are of special interest because they sometimes appear near hydrocarbon accumulations. Changes in velocity vary in strength with location; the structural picture is hidden unless the variations are accounted for by mappingmore » in depth instead of time. Preliminary observations suggest that the presence of hydrocarbons alters the lithology in the neighborhood of the trap; this hydrocarbon effect may be reflected in the rock velocity. The effect indicates a direct use of seismic velocity in exploration. This article uses the terms seismic velocity and seismic stacking velocity interchangeably. It uses ground velocity, checkshot average velocity, and well velocity interchangeably. Interval velocities are derived from seismic stacking velocities or well average velocities; they refer to velocities of subsurface intervals or zones. Interval travel time (ITT) is the reciprocal of interval velocity in microseconds per foot.« less

  20. Robust stability of interval bidirectional associative memory neural network with time delays.

    PubMed

    Liao, Xiaofeng; Wong, Kwok-wo

    2004-04-01

    In this paper, the conventional bidirectional associative memory (BAM) neural network with signal transmission delay is intervalized in order to study the bounded effect of deviations in network parameters and external perturbations. The resultant model is referred to as a novel interval dynamic BAM (IDBAM) model. By combining a number of different Lyapunov functionals with the Razumikhin technique, some sufficient conditions for the existence of unique equilibrium and robust stability are derived. These results are fairly general and can be verified easily. To go further, we extend our investigation to the time-varying delay case. Some robust stability criteria for BAM with perturbations of time-varying delays are derived. Besides, our approach for the analysis allows us to consider several different types of activation functions, including piecewise linear sigmoids with bounded activations as well as the usual C1-smooth sigmoids. We believe that the results obtained have leading significance in the design and application of BAM neural networks.

  1. An Aquatic Decomposition Scoring Method to Potentially Predict the Postmortem Submersion Interval of Bodies Recovered from the North Sea.

    PubMed

    van Daalen, Marjolijn A; de Kat, Dorothée S; Oude Grotebevelsborg, Bernice F L; de Leeuwe, Roosje; Warnaar, Jeroen; Oostra, Roelof Jan; M Duijst-Heesters, Wilma L J

    2017-03-01

    This study aimed to develop an aquatic decomposition scoring (ADS) method and investigated the predictive value of this method in estimating the postmortem submersion interval (PMSI) of bodies recovered from the North Sea. This method, consisting of an ADS item list and a pictorial reference atlas, showed a high interobserver agreement (Krippendorff's alpha ≥ 0.93) and hence proved to be valid. This scoring method was applied to data, collected from closed cases-cases in which the postmortal submersion interval (PMSI) was known-concerning bodies recovered from the North Sea from 1990 to 2013. Thirty-eight cases met the inclusion criteria and were scored by quantifying the observed total aquatic decomposition score (TADS). Statistical analysis demonstrated that TADS accurately predicts the PMSI (p < 0.001), confirming that the decomposition process in the North Sea is strongly correlated to time. © 2017 American Academy of Forensic Sciences.

  2. The interval testing procedure: A general framework for inference in functional data analysis.

    PubMed

    Pini, Alessia; Vantini, Simone

    2016-09-01

    We introduce in this work the Interval Testing Procedure (ITP), a novel inferential technique for functional data. The procedure can be used to test different functional hypotheses, e.g., distributional equality between two or more functional populations, equality of mean function of a functional population to a reference. ITP involves three steps: (i) the representation of data on a (possibly high-dimensional) functional basis; (ii) the test of each possible set of consecutive basis coefficients; (iii) the computation of the adjusted p-values associated to each basis component, by means of a new strategy here proposed. We define a new type of error control, the interval-wise control of the family wise error rate, particularly suited for functional data. We show that ITP is provided with such a control. A simulation study comparing ITP with other testing procedures is reported. ITP is then applied to the analysis of hemodynamical features involved with cerebral aneurysm pathology. ITP is implemented in the fdatest R package. © 2016, The International Biometric Society.

  3. Re-evaluation of link between interpregnancy interval and adverse birth outcomes: retrospective cohort study matching two intervals per mother

    PubMed Central

    Pereira, Gavin; Jacoby, Peter; de Klerk, Nicholas; Stanley, Fiona J

    2014-01-01

    Objective To re-evaluate the causal effect of interpregnancy interval on adverse birth outcomes, on the basis that previous studies relying on between mother comparisons may have inadequately adjusted for confounding by maternal risk factors. Design Retrospective cohort study using conditional logistic regression (matching two intervals per mother so each mother acts as her own control) to model the incidence of adverse birth outcomes as a function of interpregnancy interval; additional unconditional logistic regression with adjustment for confounders enabled comparison with the unmatched design of previous studies. Setting Perth, Western Australia, 1980-2010. Participants 40 441 mothers who each delivered three liveborn singleton neonates. Main outcome measures Preterm birth (<37 weeks), small for gestational age birth (<10th centile of birth weight by sex and gestational age), and low birth weight (<2500 g). Results Within mother analysis of interpregnancy intervals indicated a much weaker effect of short intervals on the odds of preterm birth and low birth weight compared with estimates generated using a traditional between mother analysis. The traditional unmatched design estimated an adjusted odds ratio for an interpregnancy interval of 0-5 months (relative to the reference category of 18-23 months) of 1.41 (95% confidence interval 1.31 to 1.51) for preterm birth, 1.26 (1.15 to 1.37) for low birth weight, and 0.98 (0.92 to 1.06) for small for gestational age birth. In comparison, the matched design showed a much weaker effect of short interpregnancy interval on preterm birth (odds ratio 1.07, 0.86 to 1.34) and low birth weight (1.03, 0.79 to 1.34), and the effect for small for gestational age birth remained small (1.08, 0.87 to 1.34). Both the unmatched and matched models estimated a high odds of small for gestational age birth and low birth weight for long interpregnancy intervals (longer than 59 months), but the estimated effect of long interpregnancy intervals on the odds of preterm birth was much weaker in the matched model than in the unmatched model. Conclusion This study questions the causal effect of short interpregnancy intervals on adverse birth outcomes and points to the possibility of unmeasured or inadequately specified maternal factors in previous studies. PMID:25056260

  4. High resolution in situ ultrasonic corrosion monitor

    DOEpatents

    Grossman, R.J.

    1984-01-10

    An ultrasonic corrosion monitor is provided which produces an in situ measurement of the amount of corrosion of a monitoring zone or zones of an elongate probe placed in the corrosive environment. A monitoring zone is preferably formed between the end of the probe and the junction of the zone with a lead-in portion of the probe. Ultrasonic pulses are applied to the probe and a determination made of the time interval between pulses reflected from the end of the probe and the junction referred to, both when the probe is uncorroded and while it is corroding. Corresponding electrical signals are produced and a value for the normalized transit time delay derived from these time interval measurements is used to calculate the amount of corrosion.

  5. Image discrimination models predict detection in fixed but not random noise

    NASA Technical Reports Server (NTRS)

    Ahumada, A. J. Jr; Beard, B. L.; Watson, A. B. (Principal Investigator)

    1997-01-01

    By means of a two-interval forced-choice procedure, contrast detection thresholds for an aircraft positioned on a simulated airport runway scene were measured with fixed and random white-noise masks. The term fixed noise refers to a constant, or unchanging, noise pattern for each stimulus presentation. The random noise was either the same or different in the two intervals. Contrary to simple image discrimination model predictions, the same random noise condition produced greater masking than the fixed noise. This suggests that observers seem unable to hold a new noisy image for comparison. Also, performance appeared limited by internal process variability rather than by external noise variability, since similar masking was obtained for both random noise types.

  6. High resolution in situ ultrasonic corrosion monitor

    DOEpatents

    Grossman, Robert J.

    1985-01-01

    An ultrasonic corrosion monitor is provided which produces an in situ measurement of the amount of corrosion of a monitoring zone or zones of an elongate probe placed in the corrosive environment. A monitoring zone is preferably formed between the end of the probe and the junction of the zone with a lead-in portion of the probe. Ultrasonic pulses are applied to the probe and a determination made of the time interval between pulses reflected from the end of the probe and the junction referred to, both when the probe is uncorroded and while it is corroding. Corresponding electrical signals are produced and a value for the normalized transit time delay derived from these time interval measurements is used to calculate the amount of corrosion.

  7. Intonation in unaccompanied singing: accuracy, drift, and a model of reference pitch memory.

    PubMed

    Mauch, Matthias; Frieler, Klaus; Dixon, Simon

    2014-07-01

    This paper presents a study on intonation and intonation drift in unaccompanied singing, and proposes a simple model of reference pitch memory that accounts for many of the effects observed. Singing experiments were conducted with 24 singers of varying ability under three conditions (Normal, Masked, Imagined). Over the duration of a recording, ∼50 s, a median absolute intonation drift of 11 cents was observed. While smaller than the median note error (19 cents), drift was significant in 22% of recordings. Drift magnitude did not correlate with other measures of singing accuracy, singing experience, or the presence of conditions tested. Furthermore, it is shown that neither a static intonation memory model nor a memoryless interval-based intonation model can account for the accuracy and drift behavior observed. The proposed causal model provides a better explanation as it treats the reference pitch as a changing latent variable.

  8. The production and certification of a plutonium equal-atom reference material: NBL CRM 128

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crawford, D.W.; Gradle, C.G.; Soriano, M.D.

    This report describes the design, production, and certification of the New Brunswick Laboratory plutonium equal-atom certified reference material (CRM), NBL CRM 128. The primary use of this CRM is for the determination of bias corrections encountered in the operation of a mass spectrometer. This reference material is available to the US Department of Energy contractor-operated and government-operated laboratories, as well as to the international nuclear safeguards community. The absolute, or unbiased, certified value for the CRM's Pu-242/Pu-239 ratio is 1.00063 {plus minus} 0.00026 (95% confidence interval) as of October 1, 1984. This value was obtained through the quantitative blending ofmore » high-purity, chemically and isotopically characterized separated isotopes, as well as through intercomparisons of CRM samples with calibration mixtures using thermal ionization mass spectrometry. 32 tabs.« less

  9. Prevalence of stress references on college freshmen Facebook profiles.

    PubMed

    Egan, Katie G; Moreno, Megan A

    2011-10-01

    Stress is common among college students and associated with adverse health outcomes. This study used the social networking Web site Facebook to identify self-reported stress and associated conditions among college students. Public Facebook profiles of undergraduate freshman at a large Midwestern State University (n = 300) were identified using a Facebook search. Content analysis of Facebook profiles included demographic information and displayed references to stress, weight concerns, depressive symptoms, and alcohol. The mean reported age was 18.4 years, and the majority of profile owners were female (62%). Stress references were displayed on 37% of the profiles, weight concerns on 6%, depressive symptoms on 24%, and alcohol on 73%. The display of stress references was associated with female sex (odds ratio [OR], 2.81; confidence interval [CI], 1.7-4.7), weight concerns (OR, 5.36; CI, 1.87-15.34), and depressive symptoms (OR, 2.7; CI, 1.57-4.63). No associations were found between stress and alcohol references. College freshmen frequently display references to stress on Facebook profiles with prevalence rates similar to self-reported national survey data. Findings suggest a positive association between referencing stress and both weight concerns and depressive symptoms. Facebook may be a useful venue to identify students at risk for stress-related conditions and to disseminate information about campus resources to these students.

  10. Establishment of new complete blood count reference values for healthy Thai adults.

    PubMed

    Wongkrajang, P; Chinswangwatanakul, W; Mokkhamakkun, C; Chuangsuwanich, N; Wesarachkitti, B; Thaowto, B; Laiwejpithaya, S; Komkhum, O

    2018-04-28

    Laboratory reference ranges are essential for diagnostic orientation and treatment decision. As complete blood count parameters are influenced by various factors, including gender, geographic origin, and ethnic origin, it is important to establish specific hematologic reference values for specific populations. This study was conducted at the Department of Clinical Pathology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand. Blood samples were taken from healthy adults aged 18-60 years that attended a health check-up program at our hospital during February 2015 to July 2015. Hematologic and routine chemistry analysis were performed. Participants were determined to be healthy based on medical history and routine medical examinations. Serum vitamin B12, folate, ferritin, and hemoglobin typing were also analyzed to exclude the possible presence of anemia. A statistically significant difference was observed between males and females for Hb level, hematocrit level, red blood cell count, mean corpuscular hemoglobin concentration, percentage neutrophils, monocytes and eosinophils, and absolute neutrophil, lymphocyte, basophil, and platelet counts. Accordingly, gender-specific reference intervals were established for all complete blood count parameters in healthy Thai adult population. The reference value ranges established in this study reflect significant differences between genders. It is possible that these reference ranges may be generalizable to adults living in Thailand. The findings of this study emphasize the importance of establishing specific hematologic reference values for specific populations. © 2018 John Wiley & Sons Ltd.

  11. Best Practices to Achieve the Lowest Uncertainty in Measuring with Respect

    Science.gov Websites

    been sitting in a cabinet from time to time. If control charts are used, then this interval could be 6 packaged cells or module for use in control charts to monitor the test bed and any potential drift in the reference device's calibration. Measure the control sample at least once a week. Plot percentage deviation

  12. Land Vehicle Tire Qualification

    DTIC Science & Technology

    2009-03-25

    Bead damage / separation -Severe open splices and/or liner separations - Tire induced loss of air -Exposed or broken casing -Bulges in tread or...sidewall SAE J2014 11 SAE J2014 4.14 Tire Treadlife Durability -10000 miles duration -Evaluate tread wear performance of candidate tire -Measurements at... Tread Depth measurement of reference and candidate tires taken at specified intervals • Candidate tires must complete the test and tread wear projections

  13. Total protein measurement in canine cerebrospinal fluid: agreement between a turbidimetric assay and 2 dye-binding methods and determination of reference intervals using an indirect a posteriori method.

    PubMed

    Riond, B; Steffen, F; Schmied, O; Hofmann-Lehmann, R; Lutz, H

    2014-03-01

    In veterinary clinical laboratories, qualitative tests for total protein measurement in canine cerebrospinal fluid (CSF) have been replaced by quantitative methods, which can be divided into dye-binding assays and turbidimetric methods. There is a lack of validation data and reference intervals (RIs) for these assays. The aim of the present study was to assess agreement between the turbidimetric benzethonium chloride method and 2 dye-binding methods (Pyrogallol Red-Molybdate method [PRM], Coomassie Brilliant Blue [CBB] technique) for measurement of total protein concentration in canine CSF. Furthermore, RIs were determined for all 3 methods using an indirect a posteriori method. For assay comparison, a total of 118 canine CSF specimens were analyzed. For RIs calculation, clinical records of 401 canine patients with normal CSF analysis were studied and classified according to their final diagnosis in pathologic and nonpathologic values. The turbidimetric assay showed excellent agreement with the PRM assay (mean bias 0.003 g/L [-0.26-0.27]). The CBB method generally showed higher total protein values than the turbidimetric assay and the PRM assay (mean bias -0.14 g/L for turbidimetric and PRM assay). From 90 of 401 canine patients, nonparametric reference intervals (2.5%, 97.5% quantile) were calculated (turbidimetric assay and PRM method: 0.08-0.35 g/L (90% CI: 0.07-0.08/0.33-0.39); CBB method: 0.17-0.55 g/L (90% CI: 0.16-0.18/0.52-0.61). Total protein concentration in canine CSF specimens remained stable for up to 6 months of storage at -80°C. Due to variations among methods, RIs for total protein concentration in canine CSF have to be calculated for each method. The a posteriori method of RIs calculation described here should encourage other veterinary laboratories to establish RIs that are laboratory-specific. ©2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.

  14. Reference intervals and physiologic alterations in hematologic and biochemical values of free-ranging desert tortoises in the Mojave Desert

    USGS Publications Warehouse

    Christopher, Mary M.; Berry, Kristin H.; Wallis, I.R.; Nagy, K.A.; Henen, B.T.; Peterson, C.C.

    1999-01-01

    Desert tortoise (Gopherus agassizii) populations have experienced precipitous declines resulting from the cumulative impact of habitat loss, and human and disease-related mortality. Evaluation of hematologic and biochemical responses of desert tortoises to physiologic and environmental factors can facilitate the assessment of stress and disease in tortoises and contribute to management decisions and population recovery. The goal of this study was to obtain and analyze clinical laboratory data from free-ranging desert tortoises at three sites in the Mojave Desert (California, USA) between October 1990 and October 1995, to establish reference intervals, and to develop guidelines for the interpretation of laboratory data under a variety of environmental and physiologic conditions. Body weight, carapace length, and venous blood samples for a complete blood count and clinical chemistry profile were obtained from 98 clinically healthy adult desert tortoises of both sexes at the Desert Tortoise Research Natural area (western Mojave), Goffs (eastern Mojave) and Ivanpah Valley (northeastern Mojave). Samples were obtained four times per year, in winter (February/March), spring (May/June), summer (July/August), and fall (October). Years of near-, above- and below-average rainfall were represented in the 5 yr period. Minimum, maximum and median values, and central 95 percentiles were used as reference intervals and measures of central tendency for tortoises at each site and/or season. Data were analyzed using repeated measures analysis of variance for significant (P < 0.01) variation on the basis of sex, site, season, and interactions between these variables. Significant sex differences were observed for packed cell volume, hemoglobin concentration, aspartate transaminase activity, and cholesterol, triglyceride, calcium, and phosphorus concentrations. Marked seasonal variation was observed in most parameters in conjunction with reproductive cycle, hibernation, or seasonal rainfall. Year-to-year differences and long-term alterations primarily reflected winter rainfall amounts. Site differences were minimal, and largely reflected geographic differences in precipitation patterns, such that results from these studies can be applied to other tortoise populations in environments with known rainfall and forage availability patterns.

  15. Impact of Risk Factors on Different Interval Cancer Subtypes in a Population-Based Breast Cancer Screening Programme

    PubMed Central

    Blanch, Jordi; Sala, Maria; Ibáñez, Josefa; Domingo, Laia; Fernandez, Belén; Otegi, Arantza; Barata, Teresa; Zubizarreta, Raquel; Ferrer, Joana; Castells, Xavier; Rué, Montserrat; Salas, Dolores

    2014-01-01

    Background Interval cancers are primary breast cancers diagnosed in women after a negative screening test and before the next screening invitation. Our aim was to evaluate risk factors for interval cancer and their subtypes and to compare the risk factors identified with those associated with incident screen-detected cancers. Methods We analyzed data from 645,764 women participating in the Spanish breast cancer screening program from 2000–2006 and followed-up until 2009. A total of 5,309 screen-detected and 1,653 interval cancers were diagnosed. Among the latter, 1,012 could be classified on the basis of findings in screening and diagnostic mammograms, consisting of 489 true interval cancers (48.2%), 235 false-negatives (23.2%), 172 minimal-signs (17.2%) and 114 occult tumors (11.3%). Information on the screening protocol and women's characteristics were obtained from the screening program registry. Cause-specific Cox regression models were used to estimate the hazard ratios (HR) of risks factors for interval cancer and incident screen-detected cancer. A multinomial regression model, using screen-detected tumors as a reference group, was used to assess the effect of breast density and other factors on the occurrence of interval cancer subtypes. Results A previous false-positive was the main risk factor for interval cancer (HR = 2.71, 95%CI: 2.28–3.23); this risk was higher for false-negatives (HR = 8.79, 95%CI: 6.24–12.40) than for true interval cancer (HR = 2.26, 95%CI: 1.59–3.21). A family history of breast cancer was associated with true intervals (HR = 2.11, 95%CI: 1.60–2.78), previous benign biopsy with a false-negatives (HR = 1.83, 95%CI: 1.23–2.71). High breast density was mainly associated with occult tumors (RRR = 4.92, 95%CI: 2.58–9.38), followed by true intervals (RRR = 1.67, 95%CI: 1.18–2.36) and false-negatives (RRR = 1.58, 95%CI: 1.00–2.49). Conclusion The role of women's characteristics differs among interval cancer subtypes. This information could be useful to improve effectiveness of breast cancer screening programmes and to better classify subgroups of women with different risks of developing cancer. PMID:25333936

  16. Evaluation of the 3M™ Molecular Detection Assay (MDA) 2 - Salmonella for the Detection of Salmonella spp. in Select Foods and Environmental Surfaces: Collaborative Study, First Action 2016.01.

    PubMed

    Bird, Patrick; Flannery, Jonathan; Crowley, Erin; Agin, James R; Goins, David; Monteroso, Lisa

    2016-07-01

    The 3M™ Molecular Detection Assay (MDA) 2 - Salmonella uses real-time isothermal technology for the rapid and accurate detection of Salmonella spp. from enriched select food, feed, and food-process environmental samples. The 3M MDA 2 - Salmonella was evaluated in a multilaboratory collaborative study using an unpaired study design. The 3M MDA 2 - Salmonella was compared to the U.S. Food and Drug Administration Bacteriological Analytical Manual Chapter 5 reference method for the detection of Salmonella in creamy peanut butter, and to the U.S. Department of Agriculture, Food Safety and Inspection Service Microbiology Laboratory Guidebook Chapter 4.08 reference method "Isolation and Identification of Salmonella from Meat, Poultry, Pasteurized Egg and Catfish Products and Carcass and Environmental Samples" for the detection of Salmonella in raw ground beef (73% lean). Technicians from 16 laboratories located within the continental United States participated. Each matrix was evaluated at three levels of contamination: an uninoculated control level (0 CFU/test portion), a low inoculum level (0.2-2 CFU/test portion), and a high inoculum level (2-5 CFU/test portion). Statistical analysis was conducted according to the probability of detection (POD) statistical model. Results obtained for the low inoculum level test portions produced difference in collaborator POD values of 0.03 (95% confidence interval, -0.10 to 0.16) for raw ground beef and 0.06 (95% confidence interval, -0.06 to 0.18) for creamy peanut butter, indicating no statistically significant difference between the candidate and reference methods.

  17. Expressing analytical performance from multi-sample evaluation in laboratory EQA.

    PubMed

    Thelen, Marc H M; Jansen, Rob T P; Weykamp, Cas W; Steigstra, Herman; Meijer, Ron; Cobbaert, Christa M

    2017-08-28

    To provide its participants with an external quality assessment system (EQAS) that can be used to check trueness, the Dutch EQAS organizer, Organization for Quality Assessment of Laboratory Diagnostics (SKML), has innovated its general chemistry scheme over the last decade by introducing fresh frozen commutable samples whose values were assigned by Joint Committee for Traceability in Laboratory Medicine (JCTLM)-listed reference laboratories using reference methods where possible. Here we present some important innovations in our feedback reports that allow participants to judge whether their trueness and imprecision meet predefined analytical performance specifications. Sigma metrics are used to calculate performance indicators named 'sigma values'. Tolerance intervals are based on both Total Error allowable (TEa) according to biological variation data and state of the art (SA) in line with the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Milan consensus. The existing SKML feedback reports that express trueness as the agreement between the regression line through the results of the last 12 months and the values obtained from reference laboratories and calculate imprecision from the residuals of the regression line are now enriched with sigma values calculated from the degree to which the combination of trueness and imprecision are within tolerance limits. The information and its conclusion to a simple two-point scoring system are also graphically represented in addition to the existing difference plot. By adding sigma metrics-based performance evaluation in relation to both TEa and SA tolerance intervals to its EQAS schemes, SKML provides its participants with a powerful and actionable check on accuracy.

  18. Antarctic ice-core water (USGS49) – A new isotopic reference material for δ2H and δ18O measurements of water

    USGS Publications Warehouse

    Lorenz, Jennifer M.; Qi, Haiping; Coplen, Tyler B.

    2017-01-01

    As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from ice-core water from the Amundsen–Scott South Pole Station. This isotopic reference material, designated as USGS49, was filtered, homogenised, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity and measured by dual-inlet isotope-ratio mass spectrometry. The δ2H and δ18O values of USGS49 are −394.7 ± 0.4 and −50.55 ± 0.04 mUr (where mUr = 0.001 = ‰), respectively, relative to VSMOW, on scales normalised such that the δ2H and δ18O values of SLAP reference water are, respectively, −428 and −55.5 mUr. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95% probability of encompassing the true value. This isotopic reference material is intended as one of two isotopic reference waters for daily normalisation of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer. It is available by the case of 144 glass ampoules or as a set of sixteen glass ampoules containing 5 ml of water in each ampoule.

  19. The application of Caesium-137 and Plutonium-239+240 measurements to investigate floodplain deposition in a semi-arid, low-fallout environment

    NASA Astrophysics Data System (ADS)

    Amos, K. J.; Croke, J. C.; Timmers, H.; Owens, P. N.

    2009-04-01

    Floodplains comprise geomorphologically important sources and sinks for sediments and associated pollutants, yet the sedimentology of large dryland floodplains is not well understood. Processes occurring on such floodplains are often difficult to observe, and techniques used to investigate smaller perennial floodplains are often not practical in these environments. This study assesses the utility of Cs-137 inventory and depth-profile techniques for determining relative amounts of floodplain sedimentation in the Fitzroy River, north-eastern Australia; a 143 000 km2 semi-arid river system. Caesium-137 inventories were calculated for floodplain and reference location bulk soil cores collected from four sites. Depth profiles of Cs-137 concentration from each floodplain site and a reference location were recorded. The areal density of Cs-137 at reference locations ranged from 13-978 Bq m-2 (0-1367 Bq m-2 at the 95% confidence interval), and the mean value ± 2(standard error of the mean) was 436±264 Bq m-2, similar to published data from other southern hemisphere locations. Floodplain inventories ranged from 68-1142 Bq m-2 (0-1692 Bq m-2 at the 95% confidence interval), essentially falling within the range of reference inventory values, thus preventing calculation of erosion or deposition. Depth-profiles of Cs-137 concentration indicate erosion at one site and over 66 cm of deposition at another since 1954. Analysis of 239+240Pu concentrations in a depositional core substantiated the interpretation made from Cs-137 data, and depict a more tightly constrained peak in concentration. Average annual deposition rates range from 0-15 mm. The similarity between floodplain and reference bulk inventories does not necessarily indicate a lack of erosion or deposition, due to low Cs-137 fallout in the region and associated high measurement uncertainties, and a likely influence of gully and bank eroded sediments with no or limited adsorbed Cs-137. In this low-fallout environment, detailed depth-profile data are necessary for investigating sedimentation using Cs-137.

  20. Characterization of a Recombinant Adeno-Associated Virus Type 2 Reference Standard Material

    PubMed Central

    Lock, Martin; McGorray, Susan; Auricchio, Alberto; Ayuso, Eduard; Beecham, E. Jeffrey; Blouin-Tavel, Véronique; Bosch, Fatima; Bose, Mahuya; Byrne, Barry J.; Caton, Tina; Chiorini, John A.; Chtarto, Abdelwahed; Clark, K. Reed; Conlon, Thomas; Darmon, Christophe; Doria, Monica; Douar, Anne; Flotte, Terence R.; Francis, Joyce D.; Francois, Achille; Giacca, Mauro; Korn, Michael T.; Korytov, Irina; Leon, Xavier; Leuchs, Barbara; Lux, Gabriele; Melas, Catherine; Mizukami, Hiroaki; Moullier, Philippe; Müller, Marcus; Ozawa, Keiya; Philipsberg, Tina; Poulard, Karine; Raupp, Christina; Rivière, Christel; Roosendaal, Sigrid D.; Samulski, R. Jude; Soltys, Steven M.; Surosky, Richard; Tenenbaum, Liliane; Thomas, Darby L.; van Montfort, Bart; Veres, Gabor; Wright, J. Fraser; Xu, Yili; Zelenaia, Olga; Zentilin, Lorena

    2010-01-01

    Abstract A recombinant adeno-associated virus serotype 2 Reference Standard Material (rAAV2 RSM) has been produced and characterized with the purpose of providing a reference standard for particle titer, vector genome titer, and infectious titer for AAV2 gene transfer vectors. Production and purification of the reference material were carried out by helper virus–free transient transfection and chromatographic purification. The purified bulk material was vialed, confirmed negative for microbial contamination, and then distributed for characterization along with standard assay protocols and assay reagents to 16 laboratories worldwide. Using statistical transformation and modeling of the raw data, mean titers and confidence intervals were determined for capsid particles ({X}, 9.18 × 1011 particles/ml; 95% confidence interval [CI], 7.89 × 1011 to 1.05 × 1012 particles/ml), vector genomes ({X}, 3.28 × 1010 vector genomes/ml; 95% CI, 2.70 × 1010 to 4.75 × 1010 vector genomes/ml), transducing units ({X}, 5.09 × 108 transducing units/ml; 95% CI, 2.00 × 108 to 9.60 × 108 transducing units/ml), and infectious units ({X}, 4.37 × 109 TCID50 IU/ml; 95% CI, 2.06 × 109 to 9.26 × 109 TCID50 IU/ml). Further analysis confirmed the identity of the reference material as AAV2 and the purity relative to nonvector proteins as greater than 94%. One obvious trend in the quantitative data was the degree of variation between institutions for each assay despite the relatively tight correlation of assay results within an institution. This relatively poor degree of interlaboratory precision and accuracy was apparent even though attempts were made to standardize the assays by providing detailed protocols and common reagents. This is the first time that such variation between laboratories has been thoroughly documented and the findings emphasize the need in the field for universal reference standards. The rAAV2 RSM has been deposited with the American Type Culture Collection and is available to the scientific community to calibrate laboratory-specific internal titer standards. Anticipated uses of the rAAV2 RSM are discussed. PMID:20486768

  1. A genome-wide interaction analysis of tri/tetracyclic antidepressants and RR and QT intervals: a pharmacogenomics study from the Cohorts for Heart and Aging Research in Genomic Epidemiology (CHARGE) consortium

    PubMed Central

    Noordam, Raymond; Sitlani, Colleen M; Avery, Christy L; Stewart, James D; Gogarten, Stephanie M; Wiggins, Kerri L; Trompet, Stella; Warren, Helen R; Sun, Fangui; Evans, Daniel S; Li, Xiaohui; Li, Jin; Smith, Albert V; Bis, Joshua C; Brody, Jennifer A; Busch, Evan L; Caulfield, Mark J; Chen, Yii-Der I; Cummings, Steven R; Cupples, L Adrienne; Duan, Qing; Franco, Oscar H; Méndez-Giráldez, Rául; Harris, Tamara B; Heckbert, Susan R; van Heemst, Diana; Hofman, Albert; Floyd, James S; Kors, Jan A; Launer, Lenore J; Li, Yun; Li-Gao, Ruifang; Lange, Leslie A; Lin, Henry J; de Mutsert, Renée; Napier, Melanie D; Newton-Cheh, Christopher; Poulter, Neil; Reiner, Alexander P; Rice, Kenneth M; Roach, Jeffrey; Rodriguez, Carlos J; Rosendaal, Frits R; Sattar, Naveed; Sever, Peter; Seyerle, Amanda A; Slagboom, P Eline; Soliman, Elsayed Z; Sotoodehnia, Nona; Stott, David J; Stürmer, Til; Taylor, Kent D; Thornton, Timothy A; Uitterlinden, André G; Wilhelmsen, Kirk C; Wilson, James G; Gudnason, Vilmundur; Jukema, J Wouter; Laurie, Cathy C; Liu, Yongmei; Mook-Kanamori, Dennis O; Munroe, Patricia B; Rotter, Jerome I; Vasan, Ramachandran S; Psaty, Bruce M; Stricker, Bruno H; Whitsel, Eric A

    2017-01-01

    Background Increased heart rate and a prolonged QT interval are important risk factors for cardiovascular morbidity and mortality, and can be influenced by the use of various medications, including tri/tetracyclic antidepressants (TCAs). We aim to identify genetic loci that modify the association between TCA use and RR and QT intervals. Methods and Results We conducted race/ethnic-specific genome-wide interaction analyses (with HapMap Phase II imputed reference panel imputation) of TCAs and resting RR and QT intervals in cohorts of European (n=45,706; n=1,417 TCA users), African (n=10,235; n=296 TCA users) and Hispanic/Latino (n=13,808; n=147 TCA users) ancestry, adjusted for clinical covariates. Among the populations of European ancestry, two genome-wide significant loci were identified for RR interval: rs6737205 in BRE (β = 56.3, Pinteraction = 3.9e−9) and rs9830388 in UBE2E2 (β = 25.2, Pinteraction = 1.7e−8). In Hispanic/Latino cohorts, rs2291477 in TGFBR3 significantly modified the association between TCAs and QT intervals (β = 9.3, Pinteraction = 2.55e−8). In the meta-analyses of the other ethnicities, these loci either were excluded from the meta-analyses (as part of quality control), or their effects did not reach the level of nominal statistical significance (Pinteraction > 0.05). No new variants were identified in these ethnicities. No additional loci were identified after inverse-variance-weighted meta-analysis of the three ancestries. Conclusion Among Europeans, TCA interactions with variants in BRE and UBE2E2, were identified in relation to RR intervals. Among Hispanic/Latinos, variants in TGFBR3 modified the relation between TCAs and QT intervals. Future studies are required to confirm our results. PMID:28039329

  2. Interbirth Interval and Pregnancy Complications and Outcomes: Findings from the Pregnancy Risk Assessment Monitoring System.

    PubMed

    Brunner Huber, Larissa R; Smith, Kenesha; Sha, Wei; Vick, Tara

    2018-05-25

    Although the definition of a short interbirth interval has been inconsistent in the literature, Healthy People 2020 recommends that women wait at least 18 months after a live birth before attempting their next pregnancy. In the United States, approximately 33% of pregnancies are conceived within 18 months of a previous birth. Pregnancies that result from short interbirth intervals can pose serious risks. The objective of this study was to determine the association between interbirth interval and understudied pregnancy complications and outcomes, including small for gestational age (SGA) infants, premature rupture of membranes (PROM), preterm PROM (PPROM), placenta previa, and gestational diabetes, using Pregnancy Risk Assessment and Monitoring System data from Mississippi and Tennessee. This study collected self-reported information from 2212 women on interbirth interval (≤18 months, ie, short; 19-35 months, ie, intermediate; and ≥36 months, ie, long; referent), PPROM, placenta previa, and gestational diabetes. SGA and PROM data were obtained from birth certificates. Logistic regression was used to calculate odds ratios (ORs) and 95% CIs. After adjustment, there were no strong associations between interbirth interval and PPROM, gestational diabetes, or SGA infants. However, women with shorter intervals had increased odds of PROM (short: OR, 3.54; 95% CI, 1.22-10.23 and intermediate: OR, 4.09; 95% CI, 1.28-13.03) and placenta previa (short: OR, 2.58; 95% CI, 1.10-6.05 and intermediate: OR, 1.69; 95% CI, 0.94-3.05). The study's findings provide further support for encouraging women to space their pregnancies appropriately. Moreover, findings underscore the need to provide women with family planning services so that closely spaced pregnancies and unintended pregnancies can be avoided. Additional studies of the role of interbirth interval on these understudied pregnancy complications and outcomes are warranted. © 2018 by the American College of Nurse-Midwives.

  3. Characterization of Cardiac Time Intervals in Healthy Bonnet Macaques (Macaca radiata) by Using an Electronic Stethoscope

    PubMed Central

    Kamran, Haroon; Salciccioli, Louis; Pushilin, Sergei; Kumar, Paraag; Carter, John; Kuo, John; Novotney, Carol; Lazar, Jason M

    2011-01-01

    Nonhuman primates are used frequently in cardiovascular research. Cardiac time intervals derived by phonocardiography have long been used to assess left ventricular function. Electronic stethoscopes are simple low-cost systems that display heart sound signals. We assessed the use of an electronic stethoscope to measure cardiac time intervals in 48 healthy bonnet macaques (age, 8 ± 5 y) based on recorded heart sounds. Technically adequate recordings were obtained from all animals and required 1.5 ± 1.3 min. The following cardiac time intervals were determined by simultaneously recording acoustic and single-lead electrocardiographic data: electromechanical activation time (QS1), electromechanical systole (QS2), the time interval between the first and second heart sounds (S1S2), and the time interval between the second and first sounds (S2S1). QS2 was correlated with heart rate, mean arterial pressure, diastolic blood pressure, and left ventricular ejection time determined by using echocardiography. S1S2 correlated with heart rate, mean arterial pressure, diastolic blood pressure, left ventricular ejection time, and age. S2S1 correlated with heart rate, mean arterial pressure, diastolic blood pressure, systolic blood pressure, and left ventricular ejection time. QS1 did not correlate with any anthropometric or echocardiographic parameter. The relation S1S2/S2S1 correlated with systolic blood pressure. On multivariate analyses, heart rate was the only independent predictor of QS2, S1S2, and S2S1. In conclusion, determination of cardiac time intervals is feasible and reproducible by using an electrical stethoscope in nonhuman primates. Heart rate is a major determinant of QS2, S1S2, and S2S1 but not QS1; regression equations for reference values for cardiac time intervals in bonnet macaques are provided. PMID:21439218

  4. The associations of birth intervals with small-for-gestational-age, preterm, and neonatal and infant mortality: a meta-analysis

    PubMed Central

    2013-01-01

    Background Short and long birth intervals have previously been linked to adverse neonatal outcomes. However, much of the existing literature uses cross-sectional studies, from which deriving causal inference is complex. We examine the association between short/long birth intervals and adverse neonatal outcomes by calculating and meta-analyzing associations using original data from cohort studies conducted in low-and middle-income countries (LMIC). Methods We identified five cohort studies. Adjusted odds ratios (aOR) were calculated for each study, with birth interval as the exposure and small-for-gestational-age (SGA) and/or preterm birth, and neonatal and infant mortality as outcomes. The associations were controlled for potential confounders and meta-analyzed. Results Birth interval of shorter than 18 months had statistically significant increased odds of SGA (pooled aOR: 1.51, 95% CI: 1.31-1.75), preterm (pooled aOR: 1.58, 95% CI: 1.19-2.10) and infant mortality (pooled aOR: 1.83, 95% CI: 1.19-2.81) after controlling for potential confounding factors (reference 36-<60 months). It was also significantly associated with term-SGA, preterm-appropriate-for-gestational-age, and preterm-SGA. Birth interval over 60 months had increased risk of SGA (pooled aOR: 1.22, 95% CI: 1.07-1.39) and term-SGA (pooled aOR: 1.14, 95% CI: 1.03-1.27), but was not associated with other outcomes. Conclusions Birth intervals shorter than 18 months are significantly associated with SGA, preterm birth and death in the first year of life. Lack of access to family planning interventions thus contributes to the burden of adverse birth outcomes and infant mortality in LMICs. Programs and policies must assess ways to provide equitable access to reproductive health interventions to mothers before or soon after delivering a child, but also address underlying socioeconomic factors that may modify and worsen the effect of short intervals. PMID:24564484

  5. Comparison of Characteristics and Outcomes of Asymptomatic Versus Symptomatic Left Ventricular Dysfunction in Subjects 65 Years Old or Older (from the Cardiovascular Health Study)

    PubMed Central

    Pandhi, Jay; Gottdiener, John S.; Bartz, Traci M.; Kop, Willem J.; Mehra, Mandeep R.

    2014-01-01

    Although asymptomatic left ventricular (LV) systolic dysfunction (ALVSD) is common, its phenotype and prognosis for incident heart failure (HF) and mortality are insufficiently understood. Echocardiography was done in 5,649 participants in the Cardiovascular Health Study (age 73.0 ± 5.6 years, 57.6% women). The clinical characteristics and cardiovascular risk factors of the participants with ALVSD were compared to those with normal LV function (ejection fraction ≥55%) and with symptomatic LV systolic dysfunction (SLVSD; ejection fraction <55% and a history of HF). Cox proportional hazards models were used to estimate the risk of incident HF and mortality in those with ALVSD. Also, comparisons were made among the LV ejection fraction subgroups using previously validated cutoff values (<45% and 45% to 55%), adjusting for the demographic and cardiovascular disease risk factors. Those with ALVSD (7.3%) were more likely to have cardiovascular risk factors than those in the reference group (without LV dysfunction or symptomatic HF) but less likely than those with SLVSD. The HF rate was 24 occurrences per 1,000 person-years in the reference group and 57 occurrences per 1,000 person-years in those with ALVSD. The HF rate was 45 occurrences per 1,000 person-years for those with ALVSD and mildly impaired LV dysfunction and 93 occurrences per 1,000 person-years for those with ALVSD and moderate to severe LV dysfunction. The mortality rate was 51 deaths per 1,000 person-years in the reference group, 90 deaths per 1,000 person-years in the ALVSD group, and 156 deaths per 1,000 person-years in the SLVSD group. Adjusting for covariates, compared to the reference group, ALVSD was associated with an increased risk of incident HF (hazard ratio 1.60,95% confidence interval 1.35 to 1.91), cardiovascular mortality (hazard ratio 2.13, 95% confidence interval 1.81 to 2.51), and all-cause mortality (hazard ratio 1.46, 95% confidence interval 1.29 to 1.64). In conclusion, subjects with ALVSD are characterized by a greater prevalence of cardiovascular risk factors and co-morbidities than those with normal LV function and without HF. However, the prevalence is lower than in those with SLVSD. Patients with ALVSD are at an increased risk of HF and mortality, particularly those with greater severity of LV impairment. PMID:21575752

  6. Comparison of characteristics and outcomes of asymptomatic versus symptomatic left ventricular dysfunction in subjects 65 years old or older (from the Cardiovascular Health Study).

    PubMed

    Pandhi, Jay; Gottdiener, John S; Bartz, Traci M; Kop, Willem J; Mehra, Mandeep R

    2011-06-01

    Although asymptomatic left ventricular (LV) systolic dysfunction (ALVSD) is common, its phenotype and prognosis for incident heart failure (HF) and mortality are insufficiently understood. Echocardiography was done in 5,649 participants in the Cardiovascular Health Study (age 73.0 ± 5.6 years, 57.6% women). The clinical characteristics and cardiovascular risk factors of the participants with ALVSD were compared to those with normal LV function (ejection fraction ≥55%) and with symptomatic LV systolic dysfunction (SLVSD; ejection fraction <55% and a history of HF). Cox proportional hazards models were used to estimate the risk of incident HF and mortality in those with ALVSD. Also, comparisons were made among the LV ejection fraction subgroups using previously validated cutoff values (<45% and 45% to 55%), adjusting for the demographic and cardiovascular disease risk factors. Those with ALVSD (7.3%) were more likely to have cardiovascular risk factors than those in the reference group (without LV dysfunction or symptomatic HF) but less likely than those with SLVSD. The HF rate was 24 occurrences per 1,000 person-years in the reference group and 57 occurrences per 1,000 person-years in those with ALVSD. The HF rate was 45 occurrences per 1,000 person-years for those with ALVSD and mildly impaired LV dysfunction and 93 occurrences per 1,000 person-years for those with ALVSD and moderate to severe LV dysfunction. The mortality rate was 51 deaths per 1,000 person-years in the reference group, 90 deaths per 1,000 person-years in the ALVSD group, and 156 deaths per 1,000 person-years in the SLVSD group. Adjusting for covariates, compared to the reference group, ALVSD was associated with an increased risk of incident HF (hazard ratio 1.60, 95% confidence interval 1.35 to 1.91), cardiovascular mortality (hazard ratio 2.13, 95% confidence interval 1.81 to 2.51), and all-cause mortality (hazard ratio 1.46, 95% confidence interval 1.29 to 1.64). In conclusion, subjects with ALVSD are characterized by a greater prevalence of cardiovascular risk factors and co-morbidities than those with normal LV function and without HF. However, the prevalence is lower than in those with SLVSD. Patients with ALVSD are at an increased risk of HF and mortality, particularly those with greater severity of LV impairment. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Lower reference limits of quantitative cord glucose-6-phosphate dehydrogenase estimated from healthy term neonates according to the clinical and laboratory standards institute guidelines: a cross sectional retrospective study

    PubMed Central

    2013-01-01

    Background Previous studies have reported the lower reference limit (LRL) of quantitative cord glucose-6-phosphate dehydrogenase (G6PD), but they have not used approved international statistical methodology. Using common standards is expecting to yield more true findings. Therefore, we aimed to estimate LRL of quantitative G6PD detection in healthy term neonates by using statistical analyses endorsed by the International Federation of Clinical Chemistry (IFCC) and the Clinical and Laboratory Standards Institute (CLSI) for reference interval estimation. Methods This cross sectional retrospective study was performed at King Abdulaziz Hospital, Saudi Arabia, between March 2010 and June 2012. The study monitored consecutive neonates born to mothers from one Arab Muslim tribe that was assumed to have a low prevalence of G6PD-deficiency. Neonates that satisfied the following criteria were included: full-term birth (37 weeks); no admission to the special care nursery; no phototherapy treatment; negative direct antiglobulin test; and fathers of female neonates were from the same mothers’ tribe. The G6PD activity (Units/gram Hemoglobin) was measured spectrophotometrically by an automated kit. This study used statistical analyses endorsed by IFCC and CLSI for reference interval estimation. The 2.5th percentiles and the corresponding 95% confidence intervals (CI) were estimated as LRLs, both in presence and absence of outliers. Results 207 males and 188 females term neonates who had cord blood quantitative G6PD testing met the inclusion criteria. Method of Horn detected 20 G6PD values as outliers (8 males and 12 females). Distributions of quantitative cord G6PD values exhibited a normal distribution in absence of the outliers only. The Harris-Boyd method and proportion criteria revealed that combined gender LRLs were reliable. The combined bootstrap LRL in presence of the outliers was 10.0 (95% CI: 7.5-10.7) and the combined parametric LRL in absence of the outliers was 11.0 (95% CI: 10.5-11.3). Conclusion These results contribute to the LRL of quantitative cord G6PD detection in full-term neonates. They are transferable to another laboratory when pre-analytical factors and testing methods are comparable and the IFCC-CLSI requirements of transference are satisfied. We are suggesting using estimated LRL in absence of the outliers as mislabeling G6PD-deficient neonates as normal is intolerable whereas mislabeling G6PD-normal neonates as deficient is tolerable. PMID:24016342

  8. Fragmented red cells reference range (Sysmex XN(®) automated blood cell counter).

    PubMed

    Lesesve, Jean-François; Daigney, Amandine; Henry, Sylvain; Speyer, Elodie

    2015-01-01

    Fragmented red cells (FRCs) is a new parameter automatedly determined by recent blood cell counters. Their count might be of interest because FRCs are supposed to reflect schistocytes counts measured on a stained peripheral blood smear observed under the microscope. But FRCs depend from the technical procedure used to detect them and thus reference ranges are device-dependent. The XN-9000(®) is one of the last model from Sysmex series. We aimed to establish reference range for FRCs, from 2389 controls. The mean ± SD was 0.32% ± 0.81, the median 0.02% (95% confidence interval ot the mean: 0.29-0.35%). We observed that the percentage of red blood cells with less than 17 pg of hemoglobin content (Hypo-He) was correlated to FRC increase, Hypo-He increase resulting in spurious FRCs majoration. FRCs reference range should be useful for: 1) laboratory staff in order to select which blood smears to check optically; 2) Sysmex company to set-up more optimal rules proposed with the counter (automated making of blood smear).

  9. Fragmented red cells reference range for the Sysmex XN®-series of automated blood cell counters.

    PubMed

    Lesesve, J-F; Speyer, E; Perol, J-P

    2015-10-01

    Fragmented red cells (FRCs) are a new parameter determined automatically by the latest generation of blood cell counters. FRC counts may be of interest as they may reflect schistocyte counts measured on a stained peripheral blood smear observed under the microscope. However, FRC counts depend on the technical procedure used to detect them so that reference ranges are device dependent. The XN-9000® is one of the latest models from the Sysmex series of analysers. We aimed to establish a reference range for FRCs based on 1366 normal patient samples. The mean ± SD was 0.14 ± 0.35% and the median was 0% (95% confidence interval of the mean: 0.12-0.16%). We observed that the percentage of red blood cells with <17 pg of haemoglobin content (Hypo-He) was correlated to an FRC increase and that flagged results relating to red blood cells, reticulocytes or platelets might have presented with artefactually increased FRCs. The FRCs reference range (healthy subjects) should be useful for laboratory staff for selecting which blood smears to check optically. © 2015 John Wiley & Sons Ltd.

  10. Reference values for biochemical parameters in blood serum of young and adult alpacas (Vicugna pacos).

    PubMed

    Husakova, T; Pavlata, L; Pechova, A; Hauptmanova, K; Pitropovska, E; Tichy, L

    2014-09-01

    The aim of this study was to establish reference interval for biochemical parameters in blood of alpacas on the basis of large population of clinically healthy animals, and to determine the influence of sex, age and season on nitrogen and lipid metabolites, enzymes, electrolytes, vitamins and minerals in blood of alpacas. Blood samples were collected from 311 alpacas (61 males and 201 females >6 months of age and 49 crias (21 males and 28 females) ⩽6 months of age). Selected farms were located in Central Europe (Czech Republic and Germany). We determined 24 biochemical parameters from blood serum. We performed the comparison of results by the sex of animals and for the older group also the comparison of the results with regard to the season, respectively, to the feeding period. We found no highly significant difference (P<0.01) between males and females with the exception of γ-glutamyl transferase (GGT), alkaline phosphatase (ALP) and cholesterol. We found 15 significantly different parameters between the group of crias 6 months of age and the older alpacas. Based on our findings we suggest for most parameters to use different reference intervals (especially ALP, cholesterol, total protein, globulin, non-esterified fatty acids (NEFA), GGT and phosphorus) for the two above-mentioned age groups. Another important finding is the differences between some parameters in older group of alpacas in summer/winter feeding period. Animals in the summer feeding period have higher values of parameters related to fat mobilization (β-hydroxybutyrate, NEFA) and liver metabolism (bilirubin, alanine aminotransferase). The winter period with increased feeding of supplements with higher amount of fat, vitamins and minerals is characteristic by increased values of cholesterol, triglycerides, vitamins A and E, and some minerals (K, Ca, Mg and Cl) in blood serum. Clinical laboratory diagnosis of metabolic disturbances may be improved with use of age-based reference values and with consideration of seasonal differences.

  11. Measurements of serum non-ceruloplasmin copper by a direct fluorescent method specific to Cu(II).

    PubMed

    Squitti, Rosanna; Siotto, Mariacristina; Cassetta, Emanuele; El Idrissi, Imane Ghafir; Colabufo, Nicola A

    2017-08-28

    Meta-analyses indicated the breakdown of copper homeostasis in the sporadic form of Alzheimer's disease (AD), comprising copper decreases within the brain and copper increases in the blood and the pool not bound to ceruloplasmin (non-Cp Cu, also known in the literature as "free" copper). The calculated non-Cp Cu (Walshe's) index has many limitations. A direct fluorescent method for non-Cp Cu detection has been developed and data are presented herein. The study included samples from 147 healthy subjects, 36 stable mild cognitive impairment (MCI) and 89 AD patients, who were tested for non-Cp Cu through the direct method, total serum copper, ceruloplasmin concentration and o-dianisidine ceruloplasmin activity. The indirect non-Cp Cu Walshe's index was also calculated. The direct method was linear (0.9-5.9 μM), precise (within-laboratory coefficient variation of 9.7% for low and 7.1% for high measurements), and had a good recovery. A reference interval (0-1.9 μM) was determined parametrically in 147 healthy controls (27-84 years old). The variation of non-Cp Cu was evaluated according to age and sex. Non-Cp Cu was 1.5 times higher in AD patients (regarding the upper value of the reference interval) than in healthy controls. Healthy, MCI and AD subjects were differentiated through the direct non-Cp Cu method [areas under the curve (AUC)=0.755]. Considering a 95% specificity and a 1.91 μmol/L cut-off, the sensitivity was 48.3% (confidence interval 95%: 38%-58%). The likelihood ratio (LR) was 9.94 for positive test results (LR+) and 0.54 for negative test result (LR-). The direct fluorescent test reliably and accurately measures non-Cp Cu, thereby determining the probability of having AD.

  12. Hormone modeling in preterm neonates: establishment of pituitary and steroid hormone reference intervals.

    PubMed

    Greaves, Ronda F; Pitkin, Janne; Ho, Chung Shun; Baglin, James; Hunt, Rodney W; Zacharin, Margaret R

    2015-03-01

    Reports suggest significant differences in serum levels of hormones in extremely preterm compared with late preterm and full-term infants. The purpose of this study was to develop reference intervals (RIs) for 3 pituitary hormones and 5 steroid hormones in serum of preterm infants. Blood samples were collected from 248 (128 male and 120 female) preterm neonates born between 24 and 32 weeks' gestation. PARTICIPANTS were recruited from 3 neonatal intensive care wards in Melbourne, Australia. No infant in this cohort had ambiguous genitalia or other endocrine abnormalities. All infants included in the RI determination survived beyond the equivalent of term. Serum was analyzed for prolactin, FSH, and LH by automated electrochemiluminescence immunoassay (Roche Cobas 8000-e601). Liquid chromatography coupled with tandem mass spectrometry was used for analysis of 17-hydroxyprogesterone, androstenedione, cortisol, cortisone, and testosterone. The robust method was applied to define the central 95% RI, after each hormone measure was transformed using a Box-Cox transformation to correct for asymmetry. RIs were established for 8 hormones. Gender-specific intervals were developed for FSH, LH, and testosterone. Cortisone and 17- hydroxyprogesterone required division based on gestational age, with neonates born at <30 weeks' gestation demonstrating higher levels than their older counterparts. Androstenedione, cortisol, and prolactin did not require any division within this cohort for RI assignment. This report provides the first characterization of serum steroids measured by mass spectrometry in preterm neonates, with the additional characterization of 3 pituitary hormones in infants born at ≤32 weeks' gestation. Use of these data allows for correct interpretation of results for very preterm neonates and reduces the risk of incorrect diagnosis due to misinterpretation of data.

  13. Importance of carbon isotopic data of the Permian-Triassic boundary layers in the Verkhoyansk region for the global correlation of the basal Triassic layer

    NASA Astrophysics Data System (ADS)

    Zakharov, Yu. D.; Biakov, A. S.; Richoz, S.; Horacek, M.

    2015-01-01

    This paper is dedicated to a global correlation of marine Permian-Triassic boundary layers on the basis of partially published and original data on the δ13Corg and δ13Ccarb values of the Suol section (Setorym River, South Verkhoyansk region). The section consists of six carbon isotopic intervals, which are easily distinguishable in the carbon isotopic curves for a series of Permian-Triassic reference sections of Eurasia and Northern America, including paleontologically described sections of Central Iran, Kashmir, and Southern China. This suggests that the Permian-Triassic boundary in the Suol section is close to the carbon isotopic minimum of interval IV. In light of new data, we suggest considering the upper part of the Late Permian Changhsingian Stage and the lower substage of the Early Triassic Induan Stage of Siberia in the volumes of the rank Otoceras concavum zone and the Tompophiceras pascoei and Wordieoceras decipiens zones, respectively. The O. concavum zone of the Verkhoyansk region probably corresponds to the Late Changhsingian Hypophiceras triviale zone of Greenland. The carbon isotopic intervals II, III, IV, and V in the Permian-Triassic boundary layers of the Verkhoyansk region traced in a series of the reference sections of Eurasia correspond, most likely, to intensification of volcanic activity at the end of the Late Changhsingian and to the first massive eruptions of Siberian traps at the end of the Changhsingian and the beginning of the Induan Stages. New data indicate the possible survival of ammonoids of the Otoceratoidea superfamily at the species level after mass extinction of organisms at the end of the Permian.

  14. CropWatch agroclimatic indicators (CWAIs) for weather impact assessment on global agriculture.

    PubMed

    Gommes, René; Wu, Bingfang; Zhang, Ning; Feng, Xueliang; Zeng, Hongwei; Li, Zhongyuan; Chen, Bo

    2017-02-01

    CropWatch agroclimatic indicators (CWAIs) are a monitoring tool developed by the CropWatch global crop monitoring system in the Chinese Academy of Sciences (CAS; www.cropwatch.com.cn , Wu et al Int J Digital Earth 7(2):113-137, 2014, Wu et al Remote Sens 7:3907-3933, 2015). Contrary to most other environmental and agroclimatic indicators, they are "agronomic value-added", i.e. they are spatial values averaged over agricultural areas only and they include a weighting that enhances the contribution of the areas with the largest production potential. CWAIs can be computed for any time interval (starting from dekads) and yield one synthetic value per variable over a specific area and time interval, for instance a national annual value. Therefore, they are very compatible with socio-economic and other variables that are usually reported at regular time intervals over administrative units, such as national environmental or agricultural statistics. Two of the CWAIs are satellite-based (RAIN and Photosynthetically Active radiation, PAR) while the third is ground based (TEMP, air temperature); capitals are used when specifically referring to CWAIs rather than the climate variables in general. The paper first provides an overview of some common agroclimatic indicators, describing their procedural, systemic and normative features in subsequent sections, following the terminology of Binder et al Environ Impact Assess Rev 30:71-81 (2010). The discussion focuses on the systemic and normative aspects: the CWAIs are assessed in terms of their coherent description of the agroclimatic crop environment, at different spatial scales (systemic). The final section shows that the CWAIs retain key statistical properties of the underlying climate variables and that they can be compared to a reference value and used as monitoring and early warning variables (normative).

  15. Cholesterol concentrations in lipoprotein fractions separated by anion-exchange-high-performance liquid chromatography in healthy dogs and dogs with hypercholesterolemia.

    PubMed

    Oda, Hitomi; Mori, Akihiro; Hirowatari, Yuji; Takoura, Toshie; Manita, Daisuke; Takahashi, Tomoya; Shono, Saori; Onozawa, Eri; Mizutani, Hisashi; Miki, Yohei; Itabashi, Yukiko; Sako, Toshinori

    2017-10-01

    Anion-exchange (AEX)-high-performance liquid chromatography (HPLC) for measurement of cholesterol can be used to separate serum lipoproteins (high-density lipoprotein (HDL); low-density lipoprotein (LDL); intermediate-density lipoprotein (IDL); very-low-density lipoprotein (VLDL)) in humans. However, AEX-HPLC has not been applied in veterinary practice. We had three objectives: (i) the validation of AEX-HPLC methods including the correlation of serum cholesterol concentration in lipoprotein fraction measured by AEX-HPLC and gel permeation-HPLC (GP-HPLC) in healthy dogs and those with hypercholesterolemia was investigated; (ii) the reference intervals of lipoprotein fractions measured by AEX-HPLC from healthy dogs (n=40) was established; (iii) lipoprotein fractions from the serum of healthy dogs (n=12) and dogs with hypercholesterolemia (n=23) were compared. Analytic reproducibility and precision of AEX-HPLC were acceptable. Positive correlation between serum concentrations of total cholesterol (Total-Chol), HDL cholesterol (HDL-Chol), LDL cholesterol (LDL-Chol)+IDL cholesterol (IDL-Chol), and VLDL cholesterol (VLDL-Chol) was noted for AEX-HPLC and GP-HPLC in healthy dogs and dogs with hypercholesterolemia. Reference intervals measured by AEX-HPLC for serum concentrations of Total-Chol, HDL-Chol, and LDL-Chol were determined to be 2.97-9.32, 2.79-6.57, 0.16-3.28mmol/L (2.5-97.5% interval), respectively. Furthermore, there was significant difference in lipoprotein profiles between healthy and dogs with hypercholesterolemia. These results suggest that AEX-HPLC can be used to evaluate lipoprotein profiles in dogs and could be a new useful indicator of hyperlipidemia in dogs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. CropWatch agroclimatic indicators (CWAIs) for weather impact assessment on global agriculture

    NASA Astrophysics Data System (ADS)

    Gommes, René; Wu, Bingfang; Zhang, Ning; Feng, Xueliang; Zeng, Hongwei; Li, Zhongyuan; Chen, Bo

    2017-02-01

    CropWatch agroclimatic indicators (CWAIs) are a monitoring tool developed by the CropWatch global crop monitoring system in the Chinese Academy of Sciences (CAS; http://www.cropwatch.com.cn, Wu et al Int J Digital Earth 7(2):113-137, 2014, Wu et al Remote Sens 7:3907-3933, 2015). Contrary to most other environmental and agroclimatic indicators, they are "agronomic value-added", i.e. they are spatial values averaged over agricultural areas only and they include a weighting that enhances the contribution of the areas with the largest production potential. CWAIs can be computed for any time interval (starting from dekads) and yield one synthetic value per variable over a specific area and time interval, for instance a national annual value. Therefore, they are very compatible with socio-economic and other variables that are usually reported at regular time intervals over administrative units, such as national environmental or agricultural statistics. Two of the CWAIs are satellite-based (RAIN and Photosynthetically Active radiation, PAR) while the third is ground based (TEMP, air temperature); capitals are used when specifically referring to CWAIs rather than the climate variables in general. The paper first provides an overview of some common agroclimatic indicators, describing their procedural, systemic and normative features in subsequent sections, following the terminology of Binder et al Environ Impact Assess Rev 30:71-81 (2010). The discussion focuses on the systemic and normative aspects: the CWAIs are assessed in terms of their coherent description of the agroclimatic crop environment, at different spatial scales (systemic). The final section shows that the CWAIs retain key statistical properties of the underlying climate variables and that they can be compared to a reference value and used as monitoring and early warning variables (normative).

  17. Evaluation of cerebrospinal fluid lactate and plasma lactate concentrations in anesthetized dogs with and without intracranial disease

    PubMed Central

    Caines, Deanne; Sinclair, Melissa; Wood, Darren; Valverde, Alexander; Dyson, Doris; Gaitero, Luis; Nykamp, Stephanie

    2013-01-01

    The objectives of this study were to establish a reference interval for canine cerebrospinal fluid lactate (CSFL) and to compare CSFL and plasma lactate (PL) concentrations in anesthetized dogs with and without intracranial disease. Using a prospective study, canine blood and cerebrospinal fluid were collected for lactate analysis in 11 dogs with intracranial disease after undergoing magnetic resonance imaging (MRI) (Group ID-MRI), in 10 healthy dogs post-MRI (Group H-MRI), and in 39 healthy dogs after induction of anesthesia (Group H-Sx). Dogs were anesthetized for the procedures using different anesthetic protocols. Neurological scores (NS) and sedation scores (SS) were assessed pre-anesthesia in ID-MRI dogs. The CSFL reference interval [90% confidence interval (CI) for lower and upper limits] was 1.1 (1.0 to 1.2) to 2.0 (2.0 to 2.1) mmol/L. Mean ± SD CSFL concentrations were: ID-MRI, 2.1 ± 0.8; H-MRI, 1.6 ± 0.4; and H-Sx, 1.6 ± 0.2 mmol/L. There was a tendency for higher CSFL in dogs in the ID-MRI group than in those in the H-MRI or H-Sx groups (P = 0.12). There was agreement between CSFL and PL in ID-MRI dogs (P = 0.007), but not in dogs in H-MRI (P = 0.5) or H-Sx (P = 0.2). Of the ID-MRI dogs, those with worse NS had higher CSFL (r2 = 0.44). The correlation between CSFL and PL in dogs with intracranial disease and between worse NS and higher CSFL warrants further investigation into the use of CSFL and PL for diagnostic and prognostic purposes. PMID:24124273

  18. Task shifting to clinical officer-led echocardiography screening for detecting rheumatic heart disease in Malawi, Africa.

    PubMed

    Sims Sanyahumbi, Amy; Sable, Craig A; Karlsten, Melissa; Hosseinipour, Mina C; Kazembe, Peter N; Minard, Charles G; Penny, Daniel J

    2017-08-01

    Echocardiographic screening for rheumatic heart disease in asymptomatic children may result in early diagnosis and prevent progression. Physician-led screening is not feasible in Malawi. Task shifting to mid-level providers such as clinical officers may enable more widespread screening. Hypothesis With short-course training, clinical officers can accurately screen for rheumatic heart disease using focussed echocardiography. A total of eight clinical officers completed three half-days of didactics and 2 days of hands-on echocardiography training. Clinical officers were evaluated by performing screening echocardiograms on 20 children with known rheumatic heart disease status. They indicated whether children should be referred for follow-up. Referral was indicated if mitral regurgitation measured more than 1.5 cm or there was any measurable aortic regurgitation. The κ statistic was calculated to measure referral agreement with a paediatric cardiologist. Sensitivity and specificity were estimated using a generalised linear mixed model, and were calculated on the basis of World Heart Federation diagnostic criteria. The mean κ statistic comparing clinical officer referrals with the paediatric cardiologist was 0.72 (95% confidence interval: 0.62, 0.82). The κ value ranged from a minimum of 0.57 to a maximum of 0.90. For rheumatic heart disease diagnosis, sensitivity was 0.91 (95% confidence interval: 0.86, 0.95) and specificity was 0.65 (95% confidence interval: 0.57, 0.72). There was substantial agreement between clinical officers and paediatric cardiologists on whether to refer. Clinical officers had a high sensitivity in detecting rheumatic heart disease. With short-course training, clinical officer-led echo screening for rheumatic heart disease is a viable alternative to physician-led screening in resource-limited settings.

  19. Lower Plasma Fetuin-A Levels Are Associated With a Higher Mortality Risk in Patients With Coronary Artery Disease.

    PubMed

    Chen, Xuechen; Zhang, Yuan; Chen, Qian; Li, Qing; Li, Yanping; Ling, Wenhua

    2017-11-01

    The present study was designed to evaluate the association of circulating fetuin-A with cardiovascular disease (CVD) and all-cause mortality. We measured plasma fetuin-A in 1620 patients using an enzyme-linked immunosorbent assay kit. The patients were members of the Guangdong coronary artery disease cohort and were recruited between October 2008 and December 2011. Cox regression models were used to estimate the association between plasma fetuin-A and the risk of mortality. A total of 206 deaths were recorded during a median follow-up of 5.9 years, 146 of whom died from CVD. The hazard ratios for the second and third tertiles of the fetuin-A levels (using the first tertile as a reference) were 0.65 (95% confidence interval, 0.44-0.96) and 0.51 (95% confidence interval, 0.33-0.78) for CVD mortality ( P =0.005) and 0.65 (95% confidence interval, 0.47-0.91) and 0.48 (95% confidence interval, 0.33-0.70) for all-cause mortality ( P <0.001), respectively. Lower plasma fetuin-A levels were associated with an increased risk of all-cause and CVD mortality in patients with coronary artery disease independently of traditional CVD risk factors. © 2017 American Heart Association, Inc.

  20. A new approach to correct the QT interval for changes in heart rate using a nonparametric regression model in beagle dogs.

    PubMed

    Watanabe, Hiroyuki; Miyazaki, Hiroyasu

    2006-01-01

    Over- and/or under-correction of QT intervals for changes in heart rate may lead to misleading conclusions and/or masking the potential of a drug to prolong the QT interval. This study examines a nonparametric regression model (Loess Smoother) to adjust the QT interval for differences in heart rate, with an improved fitness over a wide range of heart rates. 240 sets of (QT, RR) observations collected from each of 8 conscious and non-treated beagle dogs were used as the materials for investigation. The fitness of the nonparametric regression model to the QT-RR relationship was compared with four models (individual linear regression, common linear regression, and Bazett's and Fridericia's correlation models) with reference to Akaike's Information Criterion (AIC). Residuals were visually assessed. The bias-corrected AIC of the nonparametric regression model was the best of the models examined in this study. Although the parametric models did not fit, the nonparametric regression model improved the fitting at both fast and slow heart rates. The nonparametric regression model is the more flexible method compared with the parametric method. The mathematical fit for linear regression models was unsatisfactory at both fast and slow heart rates, while the nonparametric regression model showed significant improvement at all heart rates in beagle dogs.

Top