Sample records for provide high reliability

  1. Scheduler for multiprocessor system switch with selective pairing

    DOEpatents

    Gara, Alan; Gschwind, Michael Karl; Salapura, Valentina

    2015-01-06

    System, method and computer program product for scheduling threads in a multiprocessing system with selective pairing of processor cores for increased processing reliability. A selective pairing facility is provided that selectively connects, i.e., pairs, multiple microprocessor or processor cores to provide one highly reliable thread (or thread group). The method configures the selective pairing facility to use checking provide one highly reliable thread for high-reliability and allocate threads to corresponding processor cores indicating need for hardware checking. The method configures the selective pairing facility to provide multiple independent cores and allocate threads to corresponding processor cores indicating inherent resilience.

  2. Multiprocessor switch with selective pairing

    DOEpatents

    Gara, Alan; Gschwind, Michael K; Salapura, Valentina

    2014-03-11

    System, method and computer program product for a multiprocessing system to offer selective pairing of processor cores for increased processing reliability. A selective pairing facility is provided that selectively connects, i.e., pairs, multiple microprocessor or processor cores to provide one highly reliable thread (or thread group). Each paired microprocessor or processor cores that provide one highly reliable thread for high-reliability connect with a system components such as a memory "nest" (or memory hierarchy), an optional system controller, and optional interrupt controller, optional I/O or peripheral devices, etc. The memory nest is attached to a selective pairing facility via a switch or a bus

  3. Reliability Considerations for the Operation of Large Accelerator User Facilities

    DOE PAGES

    Willeke, F. J.

    2016-01-29

    The lecture provides an overview of considerations relevant for achieving highly reliable operation of accelerator based user facilities. The article starts with an overview of statistical reliability formalism which is followed by high reliability design considerations with examples. Finally, the article closes with operational aspects of high reliability such as preventive maintenance and spares inventory.

  4. Uncertainties in obtaining high reliability from stress-strength models

    NASA Technical Reports Server (NTRS)

    Neal, Donald M.; Matthews, William T.; Vangel, Mark G.

    1992-01-01

    There has been a recent interest in determining high statistical reliability in risk assessment of aircraft components. The potential consequences are identified of incorrectly assuming a particular statistical distribution for stress or strength data used in obtaining the high reliability values. The computation of the reliability is defined as the probability of the strength being greater than the stress over the range of stress values. This method is often referred to as the stress-strength model. A sensitivity analysis was performed involving a comparison of reliability results in order to evaluate the effects of assuming specific statistical distributions. Both known population distributions, and those that differed slightly from the known, were considered. Results showed substantial differences in reliability estimates even for almost nondetectable differences in the assumed distributions. These differences represent a potential problem in using the stress-strength model for high reliability computations, since in practice it is impossible to ever know the exact (population) distribution. An alternative reliability computation procedure is examined involving determination of a lower bound on the reliability values using extreme value distributions. This procedure reduces the possibility of obtaining nonconservative reliability estimates. Results indicated the method can provide conservative bounds when computing high reliability. An alternative reliability computation procedure is examined involving determination of a lower bound on the reliability values using extreme value distributions. This procedure reduces the possibility of obtaining nonconservative reliability estimates. Results indicated the method can provide conservative bounds when computing high reliability.

  5. On-clip high frequency reliability and failure test structures

    DOEpatents

    Snyder, Eric S.; Campbell, David V.

    1997-01-01

    Self-stressing test structures for realistic high frequency reliability characterizations. An on-chip high frequency oscillator, controlled by DC signals from off-chip, provides a range of high frequency pulses to test structures. The test structures provide information with regard to a variety of reliability failure mechanisms, including hot-carriers, electromigration, and oxide breakdown. The system is normally integrated at the wafer level to predict the failure mechanisms of the production integrated circuits on the same wafer.

  6. On-clip high frequency reliability and failure test structures

    DOEpatents

    Snyder, E.S.; Campbell, D.V.

    1997-04-29

    Self-stressing test structures for realistic high frequency reliability characterizations. An on-chip high frequency oscillator, controlled by DC signals from off-chip, provides a range of high frequency pulses to test structures. The test structures provide information with regard to a variety of reliability failure mechanisms, including hot-carriers, electromigration, and oxide breakdown. The system is normally integrated at the wafer level to predict the failure mechanisms of the production integrated circuits on the same wafer. 22 figs.

  7. Current medical staff governance and physician sensemaking: a formula for resistance to high reliability.

    PubMed

    Flitter, Marc A; Riesenmy, Kelly Rouse; van Stralen, Daved

    2012-01-01

    To offer a theoretical explanation for observed physician resistance and rejection of high reliability patient safety initiatives. A grounded theoretical qualitative approach, utilizing the organizational theory of sensemaking, provided the foundation for inductive and deductive reasoning employed to analyze medical staff rejection of two successfully performing high reliability programs at separate hospitals. Physician behaviors resistant to patient-centric high reliability processes were traced to provider-centric physician sensemaking. Research, conducted with the advantage that prospective studies have over the limitations of this retrospective investigation, is needed to evaluate the potential for overcoming physician resistance to innovation implementation, employing strategies based upon these findings and sensemaking theory in general. If hospitals are to emulate high reliability industries that do successfully manage environments of extreme hazard, physicians must be fully integrated into the complex teams required to accomplish this goal. Reforming health care, through high reliability organizing, with its attendant continuous focus on patient-centric processes, offers a distinct alternative to efforts directed primarily at reforming health care insurance. It is by changing how health care is provided that true cost efficiencies can be achieved. Technology and the insights of organizational science present the opportunity of replacing the current emphasis on privileged information with collective tools capable of providing quality and safety in health care. The fictions that have sustained a provider-centric health care system have been challenged. The benefits of patient-centric care should be obtainable.

  8. High-efficiency high-reliability optical components for a large, high-average-power visible laser system

    NASA Astrophysics Data System (ADS)

    Taylor, John R.; Stolz, Christopher J.

    1993-08-01

    Laser system performance and reliability depends on the related performance and reliability of the optical components which define the cavity and transport subsystems. High-average-power and long transport lengths impose specific requirements on component performance. The complexity of the manufacturing process for optical components requires a high degree of process control and verification. Qualification has proven effective in ensuring confidence in the procurement process for these optical components. Issues related to component reliability have been studied and provide useful information to better understand the long term performance and reliability of the laser system.

  9. High-efficiency high-reliability optical components for a large, high-average-power visible laser system

    NASA Astrophysics Data System (ADS)

    Taylor, J. R.; Stolz, C. J.

    1992-12-01

    Laser system performance and reliability depends on the related performance and reliability of the optical components which define the cavity and transport subsystems. High-average-power and long transport lengths impose specific requirements on component performance. The complexity of the manufacturing process for optical components requires a high degree of process control and verification. Qualification has proven effective in ensuring confidence in the procurement process for these optical components. Issues related to component reliability have been studied and provide useful information to better understand the long term performance and reliability of the laser system.

  10. Achieving High Reliability with People, Processes, and Technology.

    PubMed

    Saunders, Candice L; Brennan, John A

    2017-01-01

    High reliability as a corporate value in healthcare can be achieved by meeting the "Quadruple Aim" of improving population health, reducing per capita costs, enhancing the patient experience, and improving provider wellness. This drive starts with the board of trustees, CEO, and other senior leaders who ingrain high reliability throughout the organization. At WellStar Health System, the board developed an ambitious goal to become a top-decile health system in safety and quality metrics. To achieve this goal, WellStar has embarked on a journey toward high reliability and has committed to Lean management practices consistent with the Institute for Healthcare Improvement's definition of a high-reliability organization (HRO): one that is committed to the prevention of failure, early identification and mitigation of failure, and redesign of processes based on identifiable failures. In the end, a successful HRO can provide safe, effective, patient- and family-centered, timely, efficient, and equitable care through a convergence of people, processes, and technology.

  11. Interrater reliability of early intervention providers scoring the alberta infant motor scale.

    PubMed

    Blanchard, Y; Neilan, E; Busanich, J; Garavuso, L; Klimas, D

    2004-01-01

    This study was designed to examine the interrater reliability of early intervention providers scoring of the Alberta Infant Motor Scale (AIMS) and to examine whether training on the AIMS would improve their interrater reliability. Eight early intervention providers were randomly assigned to two groups. Participants in Group 1 scored the AIMS on seven videotapes of infants prior to receiving training and after training on another set of seven videotapes of infants. Participants in Group 2 scored the AIMS on all 14 videotapes of the infants after receiving training. Overall interrater reliability before and after training was high with intraclass correlation coefficients ranging from 0.98 to 0.99. Detailed examination of the results showed that training improved the reliability of the supine subscale in a subgroup of infants between the ages of five and seven months. Training also had an effect on the classification of infants as normal or abnormal in their motor development based on their percentile rankings. The AIMS manual provides sufficient information to attain high interrater reliability without training, but revisions regarding scoring are strongly recommended.

  12. Survey of Software Assurance Techniques for Highly Reliable Systems

    NASA Technical Reports Server (NTRS)

    Nelson, Stacy

    2004-01-01

    This document provides a survey of software assurance techniques for highly reliable systems including a discussion of relevant safety standards for various industries in the United States and Europe, as well as examples of methods used during software development projects. It contains one section for each industry surveyed: Aerospace, Defense, Nuclear Power, Medical Devices and Transportation. Each section provides an overview of applicable standards and examples of a mission or software development project, software assurance techniques used and reliability achieved.

  13. State recovery and lockstep execution restart in a system with multiprocessor pairing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gara, Alan; Gschwind, Michael K; Salapura, Valentina

    System, method and computer program product for a multiprocessing system to offer selective pairing of processor cores for increased processing reliability. A selective pairing facility is provided that selectively connects, i.e., pairs, multiple microprocessor or processor cores to provide one highly reliable thread (or thread group). Each paired microprocessor or processor cores that provide one highly reliable thread for high-reliability connect with a system components such as a memory "nest" (or memory hierarchy), an optional system controller, and optional interrupt controller, optional I/O or peripheral devices, etc. The memory nest is attached to a selective pairing facility via a switchmore » or a bus. Each selectively paired processor core is includes a transactional execution facility, whereing the system is configured to enable processor rollback to a previous state and reinitialize lockstep execution in order to recover from an incorrect execution when an incorrect execution has been detected by the selective pairing facility.« less

  14. High resolution time interval meter

    DOEpatents

    Martin, A.D.

    1986-05-09

    Method and apparatus are provided for measuring the time interval between two events to a higher resolution than reliability available from conventional circuits and component. An internal clock pulse is provided at a frequency compatible with conventional component operating frequencies for reliable operation. Lumped constant delay circuits are provided for generating outputs at delay intervals corresponding to the desired high resolution. An initiation START pulse is input to generate first high resolution data. A termination STOP pulse is input to generate second high resolution data. Internal counters count at the low frequency internal clock pulse rate between the START and STOP pulses. The first and second high resolution data are logically combined to directly provide high resolution data to one counter and correct the count in the low resolution counter to obtain a high resolution time interval measurement.

  15. Reliability and Failure in NASA Missions: Blunders, Normal Accidents, High Reliability, Bad Luck

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.

    2015-01-01

    NASA emphasizes crew safety and system reliability but several unfortunate failures have occurred. The Apollo 1 fire was mistakenly unanticipated. After that tragedy, the Apollo program gave much more attention to safety. The Challenger accident revealed that NASA had neglected safety and that management underestimated the high risk of shuttle. Probabilistic Risk Assessment was adopted to provide more accurate failure probabilities for shuttle and other missions. NASA's "faster, better, cheaper" initiative and government procurement reform led to deliberately dismantling traditional reliability engineering. The Columbia tragedy and Mars mission failures followed. Failures can be attributed to blunders, normal accidents, or bad luck. Achieving high reliability is difficult but possible.

  16. Impact of High-Reliability Education on Adverse Event Reporting by Registered Nurses.

    PubMed

    McFarland, Diane M; Doucette, Jeffrey N

    Adverse event reporting is one strategy to identify risks and improve patient safety, but, historically, adverse events are underreported by registered nurses (RNs) because of fear of retribution and blame. A program was provided on high reliability to examine whether education would impact RNs' willingness to report adverse events. Although the findings were not statistically significant, they demonstrated a positive impact on adverse event reporting and support the need to create a culture of high reliability.

  17. Application of a truncated normal failure distribution in reliability testing

    NASA Technical Reports Server (NTRS)

    Groves, C., Jr.

    1968-01-01

    Statistical truncated normal distribution function is applied as a time-to-failure distribution function in equipment reliability estimations. Age-dependent characteristics of the truncated function provide a basis for formulating a system of high-reliability testing that effectively merges statistical, engineering, and cost considerations.

  18. Developing Reliable Life Support for Mars

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.

    2017-01-01

    A human mission to Mars will require highly reliable life support systems. Mars life support systems may recycle water and oxygen using systems similar to those on the International Space Station (ISS). However, achieving sufficient reliability is less difficult for ISS than it will be for Mars. If an ISS system has a serious failure, it is possible to provide spare parts, or directly supply water or oxygen, or if necessary bring the crew back to Earth. Life support for Mars must be designed, tested, and improved as needed to achieve high demonstrated reliability. A quantitative reliability goal should be established and used to guide development t. The designers should select reliable components and minimize interface and integration problems. In theory a system can achieve the component-limited reliability, but testing often reveal unexpected failures due to design mistakes or flawed components. Testing should extend long enough to detect any unexpected failure modes and to verify the expected reliability. Iterated redesign and retest may be required to achieve the reliability goal. If the reliability is less than required, it may be improved by providing spare components or redundant systems. The number of spares required to achieve a given reliability goal depends on the component failure rate. If the failure rate is under estimated, the number of spares will be insufficient and the system may fail. If the design is likely to have undiscovered design or component problems, it is advisable to use dissimilar redundancy, even though this multiplies the design and development cost. In the ideal case, a human tended closed system operational test should be conducted to gain confidence in operations, maintenance, and repair. The difficulty in achieving high reliability in unproven complex systems may require the use of simpler, more mature, intrinsically higher reliability systems. The limitations of budget, schedule, and technology may suggest accepting lower and less certain expected reliability. A plan to develop reliable life support is needed to achieve the best possible reliability.

  19. Research on Horizontal Accuracy Method of High Spatial Resolution Remotely Sensed Orthophoto Image

    NASA Astrophysics Data System (ADS)

    Xu, Y. M.; Zhang, J. X.; Yu, F.; Dong, S.

    2018-04-01

    At present, in the inspection and acceptance of high spatial resolution remotly sensed orthophoto image, the horizontal accuracy detection is testing and evaluating the accuracy of images, which mostly based on a set of testing points with the same accuracy and reliability. However, it is difficult to get a set of testing points with the same accuracy and reliability in the areas where the field measurement is difficult and the reference data with high accuracy is not enough. So it is difficult to test and evaluate the horizontal accuracy of the orthophoto image. The uncertainty of the horizontal accuracy has become a bottleneck for the application of satellite borne high-resolution remote sensing image and the scope of service expansion. Therefore, this paper proposes a new method to test the horizontal accuracy of orthophoto image. This method using the testing points with different accuracy and reliability. These points' source is high accuracy reference data and field measurement. The new method solves the horizontal accuracy detection of the orthophoto image in the difficult areas and provides the basis for providing reliable orthophoto images to the users.

  20. Implementing eco friendly highly reliable upload feature using multi 3G service

    NASA Astrophysics Data System (ADS)

    Tanutama, Lukas; Wijaya, Rico

    2017-12-01

    The current trend of eco friendly Internet access is preferred. In this research the understanding of eco friendly is minimum power consumption. The devices that are selected have operationally low power consumption and normally have no power consumption as they are hibernating during idle state. To have the reliability a router of a router that has internal load balancing feature will provide the improvement of previous research on multi 3G services for broadband lines. Previous studies emphasized on accessing and downloading information files from Public Cloud residing Web Servers. The demand is not only for speed but high reliability of access as well. High reliability will mean mitigating both direct and indirect high cost due to repeated attempts of uploading and downloading the large files. Nomadic and mobile computer users need viable solution. Following solution for downloading information has been proposed and tested. The solution is promising. The result is now extended to providing reliable access line by means of redundancy and automatic reconfiguration for uploading and downloading large information files to a Web Server in the Cloud. The technique is taking advantage of internal load balancing feature to provision a redundant line acting as a backup line. A router that has the ability to provide load balancing to several WAN lines is chosen. The WAN lines are constructed using multiple 3G lines. The router supports the accessing Internet with more than one 3G access line which increases the reliability and availability of the Internet access as the second line immediately takes over if the first line is disturbed.

  1. High-density carrier-accumulated and electrically stable oxide thin-film transistors from ion-gel gate dielectric

    PubMed Central

    Fujii, Mami N.; Ishikawa, Yasuaki; Miwa, Kazumoto; Okada, Hiromi; Uraoka, Yukiharu; Ono, Shimpei

    2015-01-01

    The use of indium–gallium–zinc oxide (IGZO) has paved the way for high-resolution uniform displays or integrated circuits with transparent and flexible devices. However, achieving highly reliable devices that use IGZO for low-temperature processes remains a technological challenge. We propose the use of IGZO thin-film transistors (TFTs) with an ionic-liquid gate dielectric in order to achieve high-density carrier-accumulated IGZO TFTs with high reliability, and we discuss a distinctive mechanism for the degradation of this organic–inorganic hybrid device under long-term electrical stress. Our results demonstrated that an ionic liquid or gel gate dielectric provides highly reliable and low-voltage operation with IGZO TFTs. Furthermore, high-density carrier accumulation helps improve the TFT characteristics and reliability, and it is highly relevant to the electronic phase control of oxide materials and the degradation mechanism for organic–inorganic hybrid devices. PMID:26677773

  2. High-density carrier-accumulated and electrically stable oxide thin-film transistors from ion-gel gate dielectric.

    PubMed

    Fujii, Mami N; Ishikawa, Yasuaki; Miwa, Kazumoto; Okada, Hiromi; Uraoka, Yukiharu; Ono, Shimpei

    2015-12-18

    The use of indium-gallium-zinc oxide (IGZO) has paved the way for high-resolution uniform displays or integrated circuits with transparent and flexible devices. However, achieving highly reliable devices that use IGZO for low-temperature processes remains a technological challenge. We propose the use of IGZO thin-film transistors (TFTs) with an ionic-liquid gate dielectric in order to achieve high-density carrier-accumulated IGZO TFTs with high reliability, and we discuss a distinctive mechanism for the degradation of this organic-inorganic hybrid device under long-term electrical stress. Our results demonstrated that an ionic liquid or gel gate dielectric provides highly reliable and low-voltage operation with IGZO TFTs. Furthermore, high-density carrier accumulation helps improve the TFT characteristics and reliability, and it is highly relevant to the electronic phase control of oxide materials and the degradation mechanism for organic-inorganic hybrid devices.

  3. Inter-Rater Reliability of Provider Interpretations of Irritable Bowel Syndrome Food and Symptom Journals

    PubMed Central

    Chung, Chia-Fang; Xu, Kaiyuan; Dong, Yi; Schenk, Jeanette M.; Cain, Kevin; Munson, Sean; Heitkemper, Margaret M.

    2017-01-01

    There are currently no standardized methods for identifying trigger food(s) from irritable bowel syndrome (IBS) food and symptom journals. The primary aim of this study was to assess the inter-rater reliability of providers’ interpretations of IBS journals. A second aim was to describe whether these interpretations varied for each patient. Eight providers reviewed 17 IBS journals and rated how likely key food groups (fermentable oligo-di-monosaccharides and polyols, high-calorie, gluten, caffeine, high-fiber) were to trigger IBS symptoms for each patient. Agreement of trigger food ratings was calculated using Krippendorff’s α-reliability estimate. Providers were also asked to write down recommendations they would give to each patient. Estimates of agreement of trigger food likelihood ratings were poor (average α = 0.07). Most providers gave similar trigger food likelihood ratings for over half the food groups. Four providers gave the exact same written recommendation(s) (range 3–7) to over half the patients. Inter-rater reliability of provider interpretations of IBS food and symptom journals was poor. Providers favored certain trigger food likelihood ratings and written recommendations. This supports the need for a more standardized method for interpreting these journals and/or more rigorous techniques to accurately identify personalized IBS food triggers. PMID:29113044

  4. Methods and Costs to Achieve Ultra Reliable Life Support

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.

    2012-01-01

    A published Mars mission is used to explore the methods and costs to achieve ultra reliable life support. The Mars mission and its recycling life support design are described. The life support systems were made triply redundant, implying that each individual system will have fairly good reliability. Ultra reliable life support is needed for Mars and other long, distant missions. Current systems apparently have insufficient reliability. The life cycle cost of the Mars life support system is estimated. Reliability can be increased by improving the intrinsic system reliability, adding spare parts, or by providing technically diverse redundant systems. The costs of these approaches are estimated. Adding spares is least costly but may be defeated by common cause failures. Using two technically diverse systems is effective but doubles the life cycle cost. Achieving ultra reliability is worth its high cost because the penalty for failure is very high.

  5. Hybrid Power Management-Based Vehicle Architecture

    NASA Technical Reports Server (NTRS)

    Eichenberg, Dennis J.

    2011-01-01

    Hybrid Power Management (HPM) is the integration of diverse, state-of-the-art power devices in an optimal configuration for space and terrestrial applications (s ee figure). The appropriate application and control of the various power devices significantly improves overall system performance and efficiency. The basic vehicle architecture consists of a primary power source, and possibly other power sources, that provides all power to a common energy storage system that is used to power the drive motors and vehicle accessory systems. This architecture also provides power as an emergency power system. Each component is independent, permitting it to be optimized for its intended purpose. The key element of HPM is the energy storage system. All generated power is sent to the energy storage system, and all loads derive their power from that system. This can significantly reduce the power requirement of the primary power source, while increasing the vehicle reliability. Ultracapacitors are ideal for an HPM-based energy storage system due to their exceptionally long cycle life, high reliability, high efficiency, high power density, and excellent low-temperature performance. Multiple power sources and multiple loads are easily incorporated into an HPM-based vehicle. A gas turbine is a good primary power source because of its high efficiency, high power density, long life, high reliability, and ability to operate on a wide range of fuels. An HPM controller maintains optimal control over each vehicle component. This flexible operating system can be applied to all vehicles to considerably improve vehicle efficiency, reliability, safety, security, and performance. The HPM-based vehicle architecture has many advantages over conventional vehicle architectures. Ultracapacitors have a much longer cycle life than batteries, which greatly improves system reliability, reduces life-of-system costs, and reduces environmental impact as ultracapacitors will probably never need to be replaced and disposed of. The environmentally safe ultracapacitor components reduce disposal concerns, and their recyclable nature reduces the environmental impact. High ultracapacitor power density provides high power during surges, and the ability to absorb high power during recharging. Ultracapacitors are extremely efficient in capturing recharging energy, are rugged, reliable, maintenance-free, have excellent lowtemperature characteristic, provide consistent performance over time, and promote safety as they can be left indefinitely in a safe, discharged state whereas batteries cannot.

  6. Understanding Interrater Reliability and Validity of Risk Assessment Tools Used to Predict Adverse Clinical Events.

    PubMed

    Siedlecki, Sandra L; Albert, Nancy M

    This article will describe how to assess interrater reliability and validity of risk assessment tools, using easy-to-follow formulas, and to provide calculations that demonstrate principles discussed. Clinical nurse specialists should be able to identify risk assessment tools that provide high-quality interrater reliability and the highest validity for predicting true events of importance to clinical settings. Making best practice recommendations for assessment tool use is critical to high-quality patient care and safe practices that impact patient outcomes and nursing resources. Optimal risk assessment tool selection requires knowledge about interrater reliability and tool validity. The clinical nurse specialist will understand the reliability and validity issues associated with risk assessment tools, and be able to evaluate tools using basic calculations. Risk assessment tools are developed to objectively predict quality and safety events and ultimately reduce the risk of event occurrence through preventive interventions. To ensure high-quality tool use, clinical nurse specialists must critically assess tool properties. The better the tool's ability to predict adverse events, the more likely that event risk is mediated. Interrater reliability and validity assessment is relatively an easy skill to master and will result in better decisions when selecting or making recommendations for risk assessment tool use.

  7. High-Performance, Reliable Multicasting: Foundations for Future Internet Groupware Applications

    NASA Technical Reports Server (NTRS)

    Callahan, John; Montgomery, Todd; Whetten, Brian

    1997-01-01

    Network protocols that provide efficient, reliable, and totally-ordered message delivery to large numbers of users will be needed to support many future Internet applications. The Reliable Multicast Protocol (RMP) is implemented on top of IP multicast to facilitate reliable transfer of data for replicated databases and groupware applications that will emerge on the Internet over the next decade. This paper explores some of the basic questions and applications of reliable multicasting in the context of the development and analysis of RMP.

  8. Optimized Biasing of Pump Laser Diodes in a Highly Reliable Metrology Source for Long-Duration Space Missions

    NASA Technical Reports Server (NTRS)

    Poberezhskiy, Ilya; Chang, Daniel; Erlig, Hernan

    2011-01-01

    Non Planar Ring Oscillator (NPRO) lasers are highly attractive for metrology applications. NPRO reliability for prolonged space missions is limited by reliability of 808 nm pump diodes. Combined laser farm aging parameter allows comparing different bias approaches. Monte-Carlo software developed to calculate the reliability of laser pump architecture, perform parameter sensitivity studies To meet stringent Space Interferometry Mission (SIM) Lite lifetime reliability / output power requirements, we developed a single-mode Laser Pump Module architecture that: (1) provides 2 W of power at 808 nm with >99.7% reliability for 5.5 years (2) consists of 37 de-rated diode lasers operating at -5C, with outputs combined in a very low loss 37x1 all-fiber coupler

  9. NDE detectability of fatigue type cracks in high strength alloys

    NASA Technical Reports Server (NTRS)

    Christner, B. K.; Rummel, W. D.

    1983-01-01

    Specimens suitable for investigating the reliability of production nondestructive evaluation (NDE) to detect tightly closed fatigue cracks in high strength alloys representative of those materials used in spacecraft engine/booster construction were produced. Inconel 718 was selected as representative of nickel base alloys and Haynes 188 was selected as representative of cobalt base alloys used in this application. Cleaning procedures were developed to insure the reusability of the test specimens and a flaw detection reliability assessment of the fluorescent penetrant inspection method was performed using the test specimens produced to characterize their use for future reliability assessments and to provide additional NDE flaw detection reliability data for high strength alloys. The statistical analysis of the fluorescent penetrant inspection data was performed to determine the detection reliabilities for each inspection at a 90% probability/95% confidence level.

  10. On the design of high-rise buildings with a specified level of reliability

    NASA Astrophysics Data System (ADS)

    Dolganov, Andrey; Kagan, Pavel

    2018-03-01

    High-rise buildings have a specificity, which significantly distinguishes them from traditional buildings of high-rise and multi-storey buildings. Steel structures in high-rise buildings are advisable to be used in earthquake-proof regions, since steel, due to its plasticity, provides damping of the kinetic energy of seismic impacts. These aspects should be taken into account when choosing a structural scheme of a high-rise building and designing load-bearing structures. Currently, modern regulatory documents do not quantify the reliability of structures. Although the problem of assigning an optimal level of reliability has existed for a long time. The article shows the possibility of designing metal structures of high-rise buildings with specified reliability. Currently, modern regulatory documents do not quantify the reliability of high-rise buildings. Although the problem of assigning an optimal level of reliability has existed for a long time. It is proposed to establish the value of reliability 0.99865 (3σ) for constructions of buildings and structures of a normal level of responsibility in calculations for the first group of limiting states. For increased (construction of high-rise buildings) and reduced levels of responsibility for the provision of load-bearing capacity, it is proposed to assign respectively 0.99997 (4σ) and 0.97725 (2σ). The coefficients of the use of the cross section of a metal beam for different levels of security are given.

  11. Flexible Transparent Conductive Films with High Performance and Reliability Using Hybrid Structures of Continuous Metal Nanofiber Networks for Flexible Optoelectronics.

    PubMed

    Park, Juyoung; Hyun, Byung Gwan; An, Byeong Wan; Im, Hyeon-Gyun; Park, Young-Geun; Jang, Junho; Park, Jang-Ung; Bae, Byeong-Soo

    2017-06-21

    We report an Ag nanofiber-embedded glass-fabric reinforced hybrimer (AgNF-GFRHybrimer) composite film as a reliable and high-performance flexible transparent conducting film. The continuous AgNF network provides superior optoelectronic properties of the composite film by minimizing transmission loss and junction resistance. In addition, the excellent thermal/chemical stability and mechanical durability of the GFRHybrimer matrix provides enhanced mechanical durability and reliability of the final AgNF-GFRHybrimer composite film. To demonstrate the availability of our AgNF-GFRHybrimer composite as a transparent conducting film, we fabricated a flexible organic light-emitting diode (OLED) device on the AgNF-GFRHybrimer film; the OLED showed stable operation during a flexing.

  12. Challenges for Wireless Mesh Networks to provide reliable carrier-grade services

    NASA Astrophysics Data System (ADS)

    von Hugo, D.; Bayer, N.

    2011-08-01

    Provision of mobile and wireless services today within a competitive environment and driven by a huge amount of steadily emerging new services and applications is both challenge and chance for radio network operators. Deployment and operation of an infrastructure for mobile and wireless broadband connectivity generally requires planning effort and large investments. A promising approach to reduce expenses for radio access networking is offered by Wireless Mesh Networks (WMNs). Here traditional dedicated backhaul connections to each access point are replaced by wireless multi-hop links between neighbouring access nodes and few gateways to the backbone employing standard radio technology. Such a solution provides at the same time high flexibility in both deployment and the amount of offered capacity and shall reduce overall expenses. On the other hand currently available mesh solutions do not provide carrier grade service quality and reliability and often fail to cope with high traffic load. EU project CARMEN (CARrier grade MEsh Networks) was initiated to incorporate different heterogeneous technologies and new protocols to allow for reliable transmission over "best effort" radio channels, to support a reliable mobility and network management, self-configuration and dynamic resource usage, and thus to offer a permanent or temporary broadband access at high cost efficiency. The contribution provides an overview on preliminary project results with focus on main technical challenges from a research and implementation point of view. Especially impact of mesh topology on the overall system performance in terms of throughput and connection reliability and aspects of a dedicated hybrid mobility management solution will be discussed.

  13. Body of Knowledge (BOK) for Leadless Quad Flat No-Lead/bottom Termination Components (QFN/BTC) Package Trends and Reliability

    NASA Technical Reports Server (NTRS)

    Ghaffarian, Reza

    2014-01-01

    Bottom terminated components and quad flat no-lead (BTC/QFN) packages have been extensively used by commercial industry for more than a decade. Cost and performance advantages and the closeness of the packages to the boards make them especially unique for radio frequency (RF) applications. A number of high-reliability parts are now available in this style of package configuration. This report presents a summary of literature surveyed and provides a body of knowledge (BOK) gathered on the status of BTC/QFN and their advanced versions of multi-row QFN (MRQFN) packaging technologies. The report provides a comprehensive review of packaging trends and specifications on design, assembly, and reliability. Emphasis is placed on assembly reliability and associated key design and process parameters because they show lower life than standard leaded package assembly under thermal cycling exposures. Inspection of hidden solder joints for assuring quality is challenging and is similar to ball grid arrays (BGAs). Understanding the key BTC/QFN technology trends, applications, processing parameters, workmanship defects, and reliability behavior is important when judicially selecting and narrowing the follow-on packages for evaluation and testing, as well as for the low risk insertion in high-reliability applications.

  14. Body of Knowledge (BOK) for Leadless Quad Flat No-Lead/Bottom Termination Components (QFN/BTC) Package Trends and Reliability

    NASA Technical Reports Server (NTRS)

    Ghaffarian, Reza

    2014-01-01

    Bottom terminated components and quad flat no-lead (BTC/QFN) packages have been extensively used by commercial industry for more than a decade. Cost and performance advantages and the closeness of the packages to the boards make them especially unique for radio frequency (RF) applications. A number of high-reliability parts are now available in this style of package configuration. This report presents a summary of literature surveyed and provides a body of knowledge (BOK) gathered on the status of BTC/QFN and their advanced versions of multi-row QFN (MRQFN) packaging technologies. The report provides a comprehensive review of packaging trends and specifications on design, assembly, and reliability. Emphasis is placed on assembly reliability and associated key design and process parameters because they show lower life than standard leaded package assembly under thermal cycling exposures. Inspection of hidden solder joints for assuring quality is challenging and is similar to ball grid arrays (BGAs). Understanding the key BTC/QFN technology trends, applications, processing parameters, workmanship defects, and reliability behavior is important when judicially selecting and narrowing the follow-on packages for evaluation and testing, as well as for the low risk insertion in high-reliability applications.

  15. Integrating Formal Methods and Testing 2002

    NASA Technical Reports Server (NTRS)

    Cukic, Bojan

    2002-01-01

    Traditionally, qualitative program verification methodologies and program testing are studied in separate research communities. None of them alone is powerful and practical enough to provide sufficient confidence in ultra-high reliability assessment when used exclusively. Significant advances can be made by accounting not only tho formal verification and program testing. but also the impact of many other standard V&V techniques, in a unified software reliability assessment framework. The first year of this research resulted in the statistical framework that, given the assumptions on the success of the qualitative V&V and QA procedures, significantly reduces the amount of testing needed to confidently assess reliability at so-called high and ultra-high levels (10-4 or higher). The coming years shall address the methodologies to realistically estimate the impacts of various V&V techniques to system reliability and include the impact of operational risk to reliability assessment. Combine formal correctness verification, process and product metrics, and other standard qualitative software assurance methods with statistical testing with the aim of gaining higher confidence in software reliability assessment for high-assurance applications. B) Quantify the impact of these methods on software reliability. C) Demonstrate that accounting for the effectiveness of these methods reduces the number of tests needed to attain certain confidence level. D) Quantify and justify the reliability estimate for systems developed using various methods.

  16. Effectiveness of back-to-back testing

    NASA Technical Reports Server (NTRS)

    Vouk, Mladen A.; Mcallister, David F.; Eckhardt, David E.; Caglayan, Alper; Kelly, John P. J.

    1987-01-01

    Three models of back-to-back testing processes are described. Two models treat the case where there is no intercomponent failure dependence. The third model describes the more realistic case where there is correlation among the failure probabilities of the functionally equivalent components. The theory indicates that back-to-back testing can, under the right conditions, provide a considerable gain in software reliability. The models are used to analyze the data obtained in a fault-tolerant software experiment. It is shown that the expected gain is indeed achieved, and exceeded, provided the intercomponent failure dependence is sufficiently small. However, even with the relatively high correlation the use of several functionally equivalent components coupled with back-to-back testing may provide a considerable reliability gain. Implications of this finding are that the multiversion software development is a feasible and cost effective approach to providing highly reliable software components intended for fault-tolerant software systems, on condition that special attention is directed at early detection and elimination of correlated faults.

  17. Ultra Reliable Closed Loop Life Support for Long Space Missions

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.; Ewert, Michael K.

    2010-01-01

    Spacecraft human life support systems can achieve ultra reliability by providing sufficient spares to replace all failed components. The additional mass of spares for ultra reliability is approximately equal to the original system mass, provided that the original system reliability is not too low. Acceptable reliability can be achieved for the Space Shuttle and Space Station by preventive maintenance and by replacing failed units. However, on-demand maintenance and repair requires a logistics supply chain in place to provide the needed spares. In contrast, a Mars or other long space mission must take along all the needed spares, since resupply is not possible. Long missions must achieve ultra reliability, a very low failure rate per hour, since they will take years rather than weeks and cannot be cut short if a failure occurs. Also, distant missions have a much higher mass launch cost per kilogram than near-Earth missions. Achieving ultra reliable spacecraft life support systems with acceptable mass will require a well-planned and extensive development effort. Analysis must determine the reliability requirement and allocate it to subsystems and components. Ultra reliability requires reducing the intrinsic failure causes, providing spares to replace failed components and having "graceful" failure modes. Technologies, components, and materials must be selected and designed for high reliability. Long duration testing is needed to confirm very low failure rates. Systems design should segregate the failure causes in the smallest, most easily replaceable parts. The system must be designed, developed, integrated, and tested with system reliability in mind. Maintenance and reparability of failed units must not add to the probability of failure. The overall system must be tested sufficiently to identify any design errors. A program to develop ultra reliable space life support systems with acceptable mass should start soon since it must be a long term effort.

  18. Standard high-reliability integrated circuit logic packaging. [for deep space tracking stations

    NASA Technical Reports Server (NTRS)

    Slaughter, D. W.

    1977-01-01

    A family of standard, high-reliability hardware used for packaging digital integrated circuits is described. The design transition from early prototypes to production hardware is covered and future plans are discussed. Interconnections techniques are described as well as connectors and related hardware available at both the microcircuit packaging and main-frame level. General applications information is also provided.

  19. Helicobacter pylori therapy: a paradigm shift

    PubMed Central

    Graham, David Y; Dore, Maria Pina

    2016-01-01

    SUMMARY Helicobacter pylori (H. Pylori) is a leading cause of gastroduodenal disease, including gastric cancer. H. pylori eradication therapies and their efficacy are summarized. A number of current treatment regimens will reliably yield >90% or 95% cure rates with susceptible strains. None has proven to be superior. We show how to predict the efficacy of a regimen in any population provided one knows the prevalence of antibiotic resistance. As with other infectious diseases, therapy should always be susceptibility-based. Susceptibility testing should be demanded. We provide recommendations for empiric therapies when the only option and describe how to distinguish studies providing misinformation from those providing reliable and interpretable data. When treated as an infectious disease, high H. pylori cure rates are relatively simple to reliably achieve. PMID:27077447

  20. Objective measurements of excess skin in post bariatric patients--inter-rater reliability.

    PubMed

    Biörserud, Christina; Fagevik Olsén, Monika; Elander, Anna; Wiklund, Malin

    2016-01-01

    An ability to reliably assess excess skin after massive weight loss using well-described and transferrable methods is important. The aim of this trial was to evaluate inter-rater reliability of ptosis and circumference measurements in patients with excess skin after bariatric surgery. Twenty-five postbariatric patients were included in the study, and their excess skin was measured 18 months after surgery. A protocol was designed to measure excess skin in a standardised way. To evaluate the inter-rater reliability in the measuring protocol, all patients were measured twice, by a specialist nurse and a specialist physiotherapist. All circumference measurements on different body parts had an ICC > 0.9, indicating high reliability. Furthermore, all breast and abdominal ptosis measurements had high reliability. In contrast, visual evaluation of abdominal ptosis had poor reliability. Measurements of ptoses on different body parts had an ICC > 0.6. There were no systematic differences between the results of the two testers, except for measurements of the buttocks and maximal knee circumference. The measuring protocol presented in this study has high reliability and, therefore, represents a useful instrument to provide a consistent and objective assessment of excess skin in the postbariatric patient.

  1. Memorial Hermann: high reliability from board to bedside.

    PubMed

    Shabot, M Michael; Monroe, Douglas; Inurria, Juan; Garbade, Debbi; France, Anne-Claire

    2013-06-01

    In 2006 the Memorial Hermann Health System (MHHS), which includes 12 hospitals, began applying principles embraced by high reliability organizations (HROs). Three factors support its HRO journey: (1) aligned organizational structure with transparent management systems and compressed reporting processes; (2) Robust Process Improvement (RPI) with high-reliability interventions; and (3) cultural establishment, sustainment, and evolution. The Quality and Safety strategic plan contains three domains, each with a specific set of measures that provide goals for performance: (1) "Clinical Excellence;" (2) "Do No Harm;" and (3) "Saving Lives," as measured by the Serious Safety Event rate. MHHS uses a uniform approach to performance improvement--RPI, which includes Six Sigma, Lean, and change management, to solve difficult safety and quality problems. The 9 acute care hospitals provide multiple opportunities to integrate high-reliability interventions and best practices across MHHS. For example, MHHS partnered with the Joint Commission Center for Transforming Healthcare in its inaugural project to establish reliable hand hygiene behaviors, which improved MHHS's average hand hygiene compliance rate from 44% to 92% currently. Soon after compliance exceeded 85% at all 12 hospitals, the average rate of central line-associated bloodstream and ventilator-associated pneumonias decreased to essentially zero. MHHS's size and diversity require a disciplined approach to performance improvement and systemwide achievement of measurable success. The most significant cultural change at MHHS has been the expectation for 100% compliance with evidence-based quality measures and 0% incidence of patient harm.

  2. Temporal reliability of ultra-high field resting-state MRI for single-subject sensorimotor and language mapping.

    PubMed

    Branco, Paulo; Seixas, Daniela; Castro, São Luís

    2018-03-01

    Resting-state fMRI is a well-suited technique to map functional networks in the brain because unlike task-based approaches it requires little collaboration from subjects. This is especially relevant in clinical settings where a number of subjects cannot comply with task demands. Previous studies using conventional scanner fields have shown that resting-state fMRI is able to map functional networks in single subjects, albeit with moderate temporal reliability. Ultra-high resolution (7T) imaging provides higher signal-to-noise ratio and better spatial resolution and is thus well suited to assess the temporal reliability of mapping results, and to determine if resting-state fMRI can be applied in clinical decision making including preoperative planning. We used resting-state fMRI at ultra-high resolution to examine whether the sensorimotor and language networks are reliable over time - same session and one week after. Resting-state networks were identified for all subjects and sessions with good accuracy. Both networks were well delimited within classical regions of interest. Mapping was temporally reliable at short and medium time-scales as demonstrated by high values of overlap in the same session and one week after for both networks. Results were stable independently of data quality metrics and physiological variables. Taken together, these findings provide strong support for the suitability of ultra-high field resting-state fMRI mapping at the single-subject level. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  3. Relating design and environmental variables to reliability

    NASA Astrophysics Data System (ADS)

    Kolarik, William J.; Landers, Thomas L.

    The combination of space application and nuclear power source demands high reliability hardware. The possibilities of failure, either an inability to provide power or a catastrophic accident, must be minimized. Nuclear power experiences on the ground have led to highly sophisticated probabilistic risk assessment procedures, most of which require quantitative information to adequately assess such risks. In the area of hardware risk analysis, reliability information plays a key role. One of the lessons learned from the Three Mile Island experience is that thorough analyses of critical components are essential. Nuclear grade equipment shows some reliability advantages over commercial. However, no statistically significant difference has been found. A recent study pertaining to spacecraft electronics reliability, examined some 2500 malfunctions on more than 300 aircraft. The study classified the equipment failures into seven general categories. Design deficiencies and lack of environmental protection accounted for about half of all failures. Within each class, limited reliability modeling was performed using a Weibull failure model.

  4. Evaluation of high fidelity patient simulator in assessment of performance of anaesthetists.

    PubMed

    Weller, J M; Bloch, M; Young, S; Maze, M; Oyesola, S; Wyner, J; Dob, D; Haire, K; Durbridge, J; Walker, T; Newble, D

    2003-01-01

    There is increasing emphasis on performance-based assessment of clinical competence. The High Fidelity Patient Simulator (HPS) may be useful for assessment of clinical practice in anaesthesia, but needs formal evaluation of validity, reliability, feasibility and effect on learning. We set out to assess the reliability of a global rating scale for scoring simulator performance in crisis management. Using a global rating scale, three judges independently rated videotapes of anaesthetists in simulated crises in the operating theatre. Five anaesthetists then independently rated subsets of these videotapes. There was good agreement between raters for medical management, behavioural attributes and overall performance. Agreement was high for both the initial judges and the five additional raters. Using a global scale to assess simulator performance, we found good inter-rater reliability for scoring performance in a crisis. We estimate that two judges should provide a reliable assessment. High fidelity simulation should be studied further for assessing clinical performance.

  5. Autonomous navigation system based on GPS and magnetometer data

    NASA Technical Reports Server (NTRS)

    Julie, Thienel K. (Inventor); Richard, Harman R. (Inventor); Bar-Itzhack, Itzhack Y. (Inventor)

    2004-01-01

    This invention is drawn to an autonomous navigation system using Global Positioning System (GPS) and magnetometers for low Earth orbit satellites. As a magnetometer is reliable and always provides information on spacecraft attitude, rate, and orbit, the magnetometer-GPS configuration solves GPS initialization problem, decreasing the convergence time for navigation estimate and improving the overall accuracy. Eventually the magnetometer-GPS configuration enables the system to avoid costly and inherently less reliable gyro for rate estimation. Being autonomous, this invention would provide for black-box spacecraft navigation, producing attitude, orbit, and rate estimates without any ground input with high accuracy and reliability.

  6. HiRel: Hybrid Automated Reliability Predictor (HARP) integrated reliability tool system, (version 7.0). Volume 4: HARP Output (HARPO) graphics display user's guide

    NASA Technical Reports Server (NTRS)

    Sproles, Darrell W.; Bavuso, Salvatore J.

    1994-01-01

    The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of highly reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed at the outset to be compatible with most computing platforms and operating systems and some programs have been beta tested within the aerospace community for over 8 years. This document is a user's guide for the HiRel graphical postprocessor program HARPO (HARP Output). HARPO reads ASCII files generated by HARP. It provides an interactive plotting capability that can be used to display alternate model data for trade-off analyses. File data can also be imported to other commercial software programs.

  7. PEM-INST-001: Instructions for Plastic Encapsulated Microcircuit (PEM) Selection, Screening, and Qualification

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander; Sahu, Kusum

    2003-01-01

    Potential users of plastic encapsulated microcircuits (PEMs) need to be reminded that unlike the military system of producing robust high-reliability microcircuits that are designed to perform acceptably in a variety of harsh environments, PEMs are primarily designed for use in benign environments where equipment is easily accessed for repair or replacement. The methods of analysis applied to military products to demonstrate high reliability cannot always be applied to PEMs. This makes it difficult for users to characterize PEMs for two reasons: 1. Due to the major differences in design and construction, the standard test practices used to ensure that military devices are robust and have high reliability often cannot be applied to PEMs that have a smaller operating temperature range and are typically more frail and susceptible to moisture absorption. In contrast, high-reliability military microcircuits usually utilize large, robust, high-temperature packages that are hermetically sealed. 2. Unlike the military high-reliability system, users of PEMs have little visibility into commercial manufacturers proprietary design, materials, die traceability, and production processes and procedures. There is no central authority that monitors PEM commercial product for quality, and there are no controls in place that can be imposed across all commercial manufacturers to provide confidence to high-reliability users that a common acceptable level of quality exists for all PEMs manufacturers. Consequently, there is no guaranteed control over the type of reliability that is built into commercial product, and there is no guarantee that different lots from the same manufacturer are equally acceptable. And regarding application, there is no guarantee that commercial products intended for use in benign environments will provide acceptable performance and reliability in harsh space environments. The qualification and screening processes contained in this document are intended to detect poor-quality lots and screen out early random failures from use in space flight hardware. However, since it cannot be guaranteed that quality was designed and built into PEMs that are appropriate for space applications, users cannot screen in quality that may not exist. It must be understood that due to the variety of materials, processes, and technologies used to design and produce PEMs, this test process may not accelerate and detect all failure mechanisms. While the tests herein will increase user confidence that PEMs with otherwise unknown reliability can be used in space environments, such testing may not guarantee the same level of reliability offered by military microcircuits. PEMs should only be used where due to performance needs there are no alternatives in the military high-reliability market, and projects are willing to accept higher risk.

  8. Fair and Just Culture, Team Behavior, and Leadership Engagement: The Tools to Achieve High Reliability

    PubMed Central

    Frankel, Allan S; Leonard, Michael W; Denham, Charles R

    2006-01-01

    Background Disparate health care provider attitudes about autonomy, teamwork, and administrative operations have added to the complexity of health care delivery and are a central factor in medicine's unacceptably high rate of errors. Other industries have improved their reliability by applying innovative concepts to interpersonal relationships and administrative hierarchical structures (Chandler 1962). In the last 10 years the science of patient safety has become more sophisticated, with practical concepts identified and tested to improve the safety and reliability of care. Objective Three initiatives stand out as worthy regarding interpersonal relationships and the application of provider concerns to shape operational change: The development and implementation of Fair and Just Culture principles, the broad use of Teamwork Training and Communication, and tools like WalkRounds that promote the alignment of leadership and frontline provider perspectives through effective use of adverse event data and provider comments. Methods Fair and Just Culture, Teamwork Training, and WalkRounds are described, and implementation examples provided. The argument is made that they must be systematically and consistently implemented in an integrated fashion. Conclusions There are excellent examples of institutions applying Just Culture principles, Teamwork Training, and Leadership WalkRounds—but to date, they have not been comprehensively instituted in health care organizations in a cohesive and interdependent manner. To achieve reliability, organizations need to begin thinking about the relationship between these efforts and linking them conceptually. PMID:16898986

  9. Reliability of High I/O High Density CCGA Interconnect Electronic Packages under Extreme Thermal Environment

    NASA Technical Reports Server (NTRS)

    Ramesham, Rajeshuni

    2012-01-01

    This paper provides the experimental test results of advanced CCGA packages tested in extreme temperature thermal environments. Standard optical inspection and x-ray non-destructive inspection tools were used to assess the reliability of high density CCGA packages for deep space extreme temperature missions. Ceramic column grid array (CCGA) packages have been increasing in use based on their advantages such as high interconnect density, very good thermal and electrical performances, compatibility with standard surface-mount packaging assembly processes, and so on. CCGA packages are used in space applications such as in logic and microprocessor functions, telecommunications, payload electronics, and flight avionics. As these packages tend to have less solder joint strain relief than leaded packages or more strain relief over lead-less chip carrier packages, the reliability of CCGA packages is very important for short-term and long-term deep space missions. We have employed high density CCGA 1152 and 1272 daisy chained electronic packages in this preliminary reliability study. Each package is divided into several daisy-chained sections. The physical dimensions of CCGA1152 package is 35 mm x 35 mm with a 34 x 34 array of columns with a 1 mm pitch. The dimension of the CCGA1272 package is 37.5 mm x 37.5 mm with a 36 x 36 array with a 1 mm pitch. The columns are made up of 80% Pb/20%Sn material. CCGA interconnect electronic package printed wiring polyimide boards have been assembled and inspected using non-destructive x-ray imaging techniques. The assembled CCGA boards were subjected to extreme temperature thermal atmospheric cycling to assess their reliability for future deep space missions. The resistance of daisy-chained interconnect sections were monitored continuously during thermal cycling. This paper provides the experimental test results of advanced CCGA packages tested in extreme temperature thermal environments. Standard optical inspection and x-ray non-destructive inspection tools were used to assess the reliability of high density CCGA packages for deep space extreme temperature missions. Keywords: Extreme temperatures, High density CCGA qualification, CCGA reliability, solder joint failures, optical inspection, and x-ray inspection.

  10. Illustrated structural application of universal first-order reliability method

    NASA Technical Reports Server (NTRS)

    Verderaime, V.

    1994-01-01

    The general application of the proposed first-order reliability method was achieved through the universal normalization of engineering probability distribution data. The method superimposes prevailing deterministic techniques and practices on the first-order reliability method to surmount deficiencies of the deterministic method and provide benefits of reliability techniques and predictions. A reliability design factor is derived from the reliability criterion to satisfy a specified reliability and is analogous to the deterministic safety factor. Its application is numerically illustrated on several practical structural design and verification cases with interesting results and insights. Two concepts of reliability selection criteria are suggested. Though the method was developed to support affordable structures for access to space, the method should also be applicable for most high-performance air and surface transportation systems.

  11. Interrater reliability of Violence Risk Appraisal Guide scores provided in Canadian criminal proceedings.

    PubMed

    Edens, John F; Penson, Brittany N; Ruchensky, Jared R; Cox, Jennifer; Smith, Shannon Toney

    2016-12-01

    Published research suggests that most violence risk assessment tools have relatively high levels of interrater reliability, but recent evidence of inconsistent scores among forensic examiners in adversarial settings raises concerns about the "field reliability" of such measures. This study specifically examined the reliability of Violence Risk Appraisal Guide (VRAG) scores in Canadian criminal cases identified in the legal database, LexisNexis. Over 250 reported cases were located that made mention of the VRAG, with 42 of these cases containing 2 or more scores that could be submitted to interrater reliability analyses. Overall, scores were skewed toward higher risk categories. The intraclass correlation (ICCA1) was .66, with pairs of forensic examiners placing defendants into the same VRAG risk "bin" in 68% of the cases. For categorical risk statements (i.e., low, moderate, high), examiners provided converging assessment results in most instances (86%). In terms of potential predictors of rater disagreement, there was no evidence for adversarial allegiance in our sample. Rater disagreement in the scoring of 1 VRAG item (Psychopathy Checklist-Revised; Hare, 2003), however, strongly predicted rater disagreement in the scoring of the VRAG (r = .58). (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  12. RF-MEMS capacitive switches with high reliability

    DOEpatents

    Goldsmith, Charles L.; Auciello, Orlando H.; Carlisle, John A.; Sampath, Suresh; Sumant, Anirudha V.; Carpick, Robert W.; Hwang, James; Mancini, Derrick C.; Gudeman, Chris

    2013-09-03

    A reliable long life RF-MEMS capacitive switch is provided with a dielectric layer comprising a "fast discharge diamond dielectric layer" and enabling rapid switch recovery, dielectric layer charging and discharging that is efficient and effective to enable RF-MEMS switch operation to greater than or equal to 100 billion cycles.

  13. Telemetry Options for LDB Payloads

    NASA Technical Reports Server (NTRS)

    Field, Chris

    2017-01-01

    The Columbia Scientific Balloon Facility has been designing and building high-altitude balloon power systems for over 26 years. With that experience, we have found certain types of PV panels, batteries, and charge controllers that are reliable in stratospheric environments. The ultimate goal is to ensure that power systems will provide power reliably throughout the duration of an LDB flight. The purpose of this presentation is to provide some general guidelines and best practices for power system design.

  14. B-52 stability augmentation system reliability

    NASA Technical Reports Server (NTRS)

    Bowling, T. C.; Key, L. W.

    1976-01-01

    The B-52 SAS (Stability Augmentation System) was developed and retrofitted to nearly 300 aircraft. It actively controls B-52 structural bending, provides improved yaw and pitch damping through sensors and electronic control channels, and puts complete reliance on hydraulic control power for rudder and elevators. The system has experienced over 300,000 flight hours and has exhibited service reliability comparable to the results of the reliability test program. Development experience points out numerous lessons with potential application in the mechanization and development of advanced technology control systems of high reliability.

  15. One-year test-retest reliability of intrinsic connectivity network fMRI in older adults

    PubMed Central

    Guo, Cong C.; Kurth, Florian; Zhou, Juan; Mayer, Emeran A.; Eickhoff, Simon B; Kramer, Joel H.; Seeley, William W.

    2014-01-01

    “Resting-state” or task-free fMRI can assess intrinsic connectivity network (ICN) integrity in health and disease, suggesting a potential for use of these methods as disease-monitoring biomarkers. Numerous analytical options are available, including model-driven ROI-based correlation analysis and model-free, independent component analysis (ICA). High test-retest reliability will be a necessary feature of a successful ICN biomarker, yet available reliability data remains limited. Here, we examined ICN fMRI test-retest reliability in 24 healthy older subjects scanned roughly one year apart. We focused on the salience network, a disease-relevant ICN not previously subjected to reliability analysis. Most ICN analytical methods proved reliable (intraclass coefficients > 0.4) and could be further improved by wavelet analysis. Seed-based ROI correlation analysis showed high map-wise reliability, whereas graph theoretical measures and temporal concatenation group ICA produced the most reliable individual unit-wise outcomes. Including global signal regression in ROI-based correlation analyses reduced reliability. Our study provides a direct comparison between the most commonly used ICN fMRI methods and potential guidelines for measuring intrinsic connectivity in aging control and patient populations over time. PMID:22446491

  16. Identifying Gifted Preschoolers in Turkey: The Reliability and Validity of the Turkish-Translated Version of the GRS-Preschool/Kindergarten Form

    ERIC Educational Resources Information Center

    Karadag, Filiz; Karabey, Burak; Pfeiffer, Steven

    2016-01-01

    The reliability and validity of the Turkish-translated version of the Gifted Rating Scales (GRS) were tested on 30 preschool teachers who provided ratings for a total of 390 preschoolers aged ranging from 4 years, 0 months to 6 years, 11 months. Results indicated that the reliability and validity of all five of the GRS-P subscales were high.…

  17. Automation in visual inspection tasks: X-ray luggage screening supported by a system of direct, indirect or adaptable cueing with low and high system reliability.

    PubMed

    Chavaillaz, Alain; Schwaninger, Adrian; Michel, Stefan; Sauer, Juergen

    2018-05-25

    The present study evaluated three automation modes for improving performance in an X-ray luggage screening task. 140 participants were asked to detect the presence of prohibited items in X-ray images of cabin luggage. Twenty participants conducted this task without automatic support (control group), whereas the others worked with either indirect cues (system indicated the target presence without specifying its location), or direct cues (system pointed out the exact target location) or adaptable automation (participants could freely choose between no cue, direct and indirect cues). Furthermore, automatic support reliability was manipulated (low vs. high). The results showed a clear advantage for direct cues regarding detection performance and response time. No benefits were observed for adaptable automation. Finally, high automation reliability led to better performance and higher operator trust. The findings overall confirmed that automatic support systems for luggage screening should be designed such that they provide direct, highly reliable cues.

  18. The Importance of Human Reliability Analysis in Human Space Flight: Understanding the Risks

    NASA Technical Reports Server (NTRS)

    Hamlin, Teri L.

    2010-01-01

    HRA is a method used to describe, qualitatively and quantitatively, the occurrence of human failures in the operation of complex systems that affect availability and reliability. Modeling human actions with their corresponding failure in a PRA (Probabilistic Risk Assessment) provides a more complete picture of the risk and risk contributions. A high quality HRA can provide valuable information on potential areas for improvement, including training, procedural, equipment design and need for automation.

  19. Control of a 30 cm diameter mercury bombardment thruster

    NASA Technical Reports Server (NTRS)

    Terdan, F. F.; Bechtel, R. T.

    1973-01-01

    Increased thruster performance has made closed-loop automatic control more difficult than previously. Specifically, high perveance optics tend to make reliable recycling more difficult. Control logic functions were established for three automatic modes of operation of a 30-cm thruster using a power conditioner console with flight-like characteristics. The three modes provide (1) automatic startup to reach thermal stability, (2) steady-state closed-loop control, and (3) the reliable recycling of the high voltages following an arc breakdown to reestablish normal operation. Power supply impedance characteristics necessary for stable operation and the effect of the magnetic baffle on the reliable recycling was studied.

  20. National audit of continence care: laying the foundation.

    PubMed

    Mian, Sarah; Wagg, Adrian; Irwin, Penny; Lowe, Derek; Potter, Jonathan; Pearson, Michael

    2005-12-01

    National audit provides a basis for establishing performance against national standards, benchmarking against other service providers and improving standards of care. For effective audit, clinical indicators are required that are valid, feasible to apply and reliable. This study describes the methods used to develop clinical indicators of continence care in preparation for a national audit. To describe the methods used to develop and test clinical indicators of continence care with regard to validity, feasibility and reliability. A multidisciplinary working group developed clinical indicators that measured the structure, process and outcome of care as well as case-mix variables. Literature searching, consensus workshops and a Delphi process were used to develop the indicators. The indicators were tested in 15 secondary care sites, 15 primary care sites and 15 long-term care settings. The process of development produced indicators that received a high degree of consensus within the Delphi process. Testing of the indicators demonstrated an internal reliability of 0.7 and an external reliability of 0.6. Data collection required significant investment in terms of staff time and training. The method used produced indicators that achieved a high degree of acceptance from health care professionals. The reliability of data collection was high for this audit and was similar to the level seen in other successful national audits. Data collection for the indicators was feasible to collect, however, issues of time and staffing were identified as limitations to such data collection. The study has described a systematic method for developing clinical indicators for national audit. The indicators proved robust and reliable in primary and secondary care as well as long-term care settings.

  1. Radioistopes to Solar to High Energy Accelerators - Chip-Scale Energy Sources

    NASA Astrophysics Data System (ADS)

    Lal, Amit

    2013-12-01

    This talk will present MEMS based power sources that utilize radioisotopes, solar energy, and potentially nuclear energy through advancements in integration of new structures and materials within MEMS. Micro power harvesters can harness power from vibration, radioisotopes, light, sound, and biology may provide pathways to minimize or even eliminate batteries in sensor nodes. In this talk work on radioisotope thin films for MEMS will be include the self-reciprocating cantilever, betavoltaic cells, and high DC voltages. The self-reciprocating cantilever energy harvester allows small commercially viable amounts of radioisotopes to generate mW to Watts of power so that very reliable power sources that last 100s of years are possible. The tradeoffs between reliability and potential stigma with radioisotopes allow one to span a useful design space with reliability as a key parameter. These power sources provide pulsed power at three different time scales using mechanical, RF, and static extraction of energy from collected charge. Multi-use capability, both harvesting radioisotope power and local vibration energy extends the reliability of micro-power sources further.

  2. Operator adaptation to changes in system reliability under adaptable automation.

    PubMed

    Chavaillaz, Alain; Sauer, Juergen

    2017-09-01

    This experiment examined how operators coped with a change in system reliability between training and testing. Forty participants were trained for 3 h on a complex process control simulation modelling six levels of automation (LOA). In training, participants either experienced a high- (100%) or low-reliability system (50%). The impact of training experience on operator behaviour was examined during a 2.5 h testing session, in which participants either experienced a high- (100%) or low-reliability system (60%). The results showed that most operators did not often switch between LOA. Most chose an LOA that relieved them of most tasks but maintained their decision authority. Training experience did not have a strong impact on the outcome measures (e.g. performance, complacency). Low system reliability led to decreased performance and self-confidence. Furthermore, complacency was observed under high system reliability. Overall, the findings suggest benefits of adaptable automation because it accommodates different operator preferences for LOA. Practitioner Summary: The present research shows that operators can adapt to changes in system reliability between training and testing sessions. Furthermore, it provides evidence that each operator has his/her preferred automation level. Since this preference varies strongly between operators, adaptable automation seems to be suitable to accommodate these large differences.

  3. Temporal reliability and lateralization of the resting-state language network.

    PubMed

    Zhu, Linlin; Fan, Yang; Zou, Qihong; Wang, Jue; Gao, Jia-Hong; Niu, Zhendong

    2014-01-01

    The neural processing loop of language is complex but highly associated with Broca's and Wernicke's areas. The left dominance of these two areas was the earliest observation of brain asymmetry. It was demonstrated that the language network and its functional asymmetry during resting state were reproducible across institutions. However, the temporal reliability of resting-state language network and its functional asymmetry are still short of knowledge. In this study, we established a seed-based resting-state functional connectivity analysis of language network with seed regions located at Broca's and Wernicke's areas, and investigated temporal reliability of language network and its functional asymmetry. The language network was found to be temporally reliable in both short- and long-term. In the aspect of functional asymmetry, the Broca's area was found to be left lateralized, while the Wernicke's area is mainly right lateralized. Functional asymmetry of these two areas revealed high short- and long-term reliability as well. In addition, the impact of global signal regression (GSR) on reliability of the resting-state language network was investigated, and our results demonstrated that GSR had negligible effect on the temporal reliability of the resting-state language network. Our study provided methodology basis for future cross-culture and clinical researches of resting-state language network and suggested priority of adopting seed-based functional connectivity for its high reliability.

  4. Temporal Reliability and Lateralization of the Resting-State Language Network

    PubMed Central

    Zou, Qihong; Wang, Jue; Gao, Jia-Hong; Niu, Zhendong

    2014-01-01

    The neural processing loop of language is complex but highly associated with Broca's and Wernicke's areas. The left dominance of these two areas was the earliest observation of brain asymmetry. It was demonstrated that the language network and its functional asymmetry during resting state were reproducible across institutions. However, the temporal reliability of resting-state language network and its functional asymmetry are still short of knowledge. In this study, we established a seed-based resting-state functional connectivity analysis of language network with seed regions located at Broca's and Wernicke's areas, and investigated temporal reliability of language network and its functional asymmetry. The language network was found to be temporally reliable in both short- and long-term. In the aspect of functional asymmetry, the Broca's area was found to be left lateralized, while the Wernicke's area is mainly right lateralized. Functional asymmetry of these two areas revealed high short- and long-term reliability as well. In addition, the impact of global signal regression (GSR) on reliability of the resting-state language network was investigated, and our results demonstrated that GSR had negligible effect on the temporal reliability of the resting-state language network. Our study provided methodology basis for future cross-culture and clinical researches of resting-state language network and suggested priority of adopting seed-based functional connectivity for its high reliability. PMID:24475058

  5. Compact high reliability fiber coupled laser diodes for avionics and related applications

    NASA Astrophysics Data System (ADS)

    Daniel, David R.; Richards, Gordon S.; Janssen, Adrian P.; Turley, Stephen E. H.; Stockton, Thomas E.

    1993-04-01

    This paper describes a newly developed compact high reliability fiber coupled laser diode which is capable of providing enhanced performance under extreme environmental conditions including a very wide operating temperature range. Careful choice of package materials to minimize thermal and mechanical stress, used with proven manufacturing methods, has resulted in highly stable coupling of the optical fiber pigtail to a high performance MOCVD-grown Multi-Quantum Well laser chip. Electro-optical characteristics over temperature are described together with a demonstration of device stability over a range of environmental conditions. Real time device lifetime data is also presented.

  6. Fix These First: How the World's Leading Companies Point the Way Toward High Reliability in the Military Health System.

    PubMed

    Beauvais, Brad; Richter, Jason; Brezinski, Paul

    The 2014 Military Health System Review calls for healthcare system leaders to implement effective strategies used by other high-performing organizations. The authors state, " the [military health system] MHS can create an optimal healthcare environment that focuses on continuous quality improvement where every patient receives safe, high-quality care at all times" (Military Health System, 2014, p. 1). Although aspirational, the document does not specify how a highly reliable health system is developed or what systemic factors are necessary to sustain highly reliable performance. Our work seeks to address this gap and provide guidance to MHS leaders regarding how high-performing organizations develop exceptional levels of performance.The authors' expectation is that military medicine will draw on these lessons to enhance leadership, develop exceptional organizational cultures, onboard and engage employees, build customer loyalty, and improve quality of care. Leaders from other segments of the healthcare field likely will find this study valuable given the size of the military healthcare system (9.6 million beneficiaries), the United States' steady progression toward population-based health, and the increasing need for highly reliable systems and performance.

  7. Requirements for Printed Wiring Boards

    NASA Technical Reports Server (NTRS)

    1984-01-01

    In order to maintain the high standards of the NASA printed wiring programs, this publication: prescribes NASA's requirements for assuring reliable rigid printed wiring boards; describes and incorporates basic considerations necessary to assure reliable rigid printed wiring boards; establishes the supplier's responsibility to train and certify personnel; provides for supplier documentation of the fabrication and inspection procedures to be used for NASA work, including supplier innovations and changes in technology; and provides visual workmanship standards to aid those responsible for determining quality conformance to the established requirements.

  8. A reliability and mass perspective of SP-100 Stirling cycle lunar-base powerplant designs

    NASA Technical Reports Server (NTRS)

    Bloomfield, Harvey S.

    1991-01-01

    The purpose was to obtain reliability and mass perspectives on selection of space power system conceptual designs based on SP-100 reactor and Stirling cycle power-generation subsystems. The approach taken was to: (1) develop a criterion for an acceptable overall reliability risk as a function of the expected range of emerging technology subsystem unit reliabilities; (2) conduct reliability and mass analyses for a diverse matrix of 800-kWe lunar-base design configurations employing single and multiple powerplants with both full and partial subsystem redundancy combinations; and (3) derive reliability and mass perspectives on selection of conceptual design configurations that meet an acceptable reliability criterion with the minimum system mass increase relative to reference powerplant design. The developed perspectives provided valuable insight into the considerations required to identify and characterize high-reliability and low-mass lunar-base powerplant conceptual design.

  9. Children's Reaction to Types of Television. Technical Report No. 28.

    ERIC Educational Resources Information Center

    Hines, Brainard W.

    An observational system having high inter-rater reliability and providing a reliable estimate of patterns of behavior across time periods is developed and tested for use in evaluating children's responses to a number of television styles and modes of presentation. This project was designed to meet three goals: first, to develop a valid and…

  10. Evaluation of hydrate-screening methods.

    PubMed

    Cui, Yong; Yao, Erica

    2008-07-01

    The purpose of this work is to evaluate the effectiveness and reliability of several common hydrate-screening techniques, and to provide guidelines for designing hydrate-screening programs for new drug candidates. Ten hydrate-forming compounds were selected as model compounds and six hydrate-screening approaches were applied to these compounds in an effort to generate their hydrate forms. The results prove that no screening approach is universally effective in finding hydrates for small organic compounds. Rather, a combination of different methods should be used to improve screening reliability. Among the approaches tested, the dynamic water vapor sorption/desorption isotherm (DVI) method and storage under high humidity (HH) yielded 60-70% success ratios, the lowest among all techniques studied. The risk of false negatives arises in particular for nonhygroscopic compounds. On the other hand, both slurry in water (Slurry) and temperature cycling of aqueous suspension (TCS) showed high success rates (90%) with some exceptions. The mixed solvent systems (MSS) procedure also achieved high success rates (90%), and was found to be more suitable for water-insoluble compounds. For water-soluble compounds, MSS may not be the best approach because recrystallization is difficult in solutions with high water activity. Finally, vapor diffusion (VD) yielded a reasonably high success ratio in finding hydrates (80%). However, this method suffers from experimental difficulty and unreliable results for either highly water-soluble or water-insoluble compounds. This study indicates that a reliable hydrate-screening strategy should take into consideration the solubility and hygroscopicity of the compounds studied. A combination of the Slurry or TCS method with the MSS procedure could provide a screening strategy with reasonable reliability.

  11. Implications of scaling on static RAM bit cell stability and reliability

    NASA Astrophysics Data System (ADS)

    Coones, Mary Ann; Herr, Norm; Bormann, Al; Erington, Kent; Soorholtz, Vince; Sweeney, John; Phillips, Michael

    1993-01-01

    In order to lower manufacturing costs and increase performance, static random access memory (SRAM) bit cells are scaled progressively toward submicron geometries. The reliability of an SRAM is highly dependent on the bit cell stability. Smaller memory cells with less capacitance and restoring current make the array more susceptible to failures from defectivity, alpha hits, and other instabilities and leakage mechanisms. Improving long term reliability while migrating to higher density devices makes the task of building in and improving reliability increasingly difficult. Reliability requirements for high density SRAMs are very demanding with failure rates of less than 100 failures per billion device hours (100 FITs) being a common criteria. Design techniques for increasing bit cell stability and manufacturability must be implemented in order to build in this level of reliability. Several types of analyses are performed to benchmark the performance of the SRAM device. Examples of these analysis techniques which are presented here include DC parametric measurements of test structures, functional bit mapping of the circuit used to characterize the entire distribution of bits, electrical microprobing of weak and/or failing bits, and system and accelerated soft error rate measurements. These tests allow process and design improvements to be evaluated prior to implementation on the final product. These results are used to provide comprehensive bit cell characterization which can then be compared to device models and adjusted accordingly to provide optimized cell stability versus cell size for a particular technology. The result is designed in reliability which can be accomplished during the early stages of product development.

  12. Quasi-CW Laser Diode Bar Life Tests

    NASA Technical Reports Server (NTRS)

    Stephen, Mark A.; Krainak, Michael A.; Dallas, Joseph L.

    1997-01-01

    NASA's Goddard Space Flight Center is developing technology for satellite-based, high peak power, LIDAR transmitters requiring 3-5 years of reliable operation. Semi-conductor laser diodes provide high efficiency pumping of solid state lasers with the promise of long-lived, reliable operation. 100-watt quasi- CW laser diode bars have been baselined for the next generation laser altimeters. Multi-billion shot lifetimes are required. The authors have monitored the performance of several diodes for billions of shots and investigated operational modes for improving diode lifetime.

  13. Thermocouples of tantalum and rhenium alloys for more stable vacuum-high temperature performance

    NASA Technical Reports Server (NTRS)

    Morris, J. F. (Inventor)

    1977-01-01

    Thermocouples of the present invention provide stability and performance reliability in systems involving high temperatures and vacuums by employing a bimetallic thermocouple sensor wherein each metal of the sensor is selected from a group of metals comprising tantalum and rhenium and alloys containing only those two metals. The tantalum, rhenium thermocouple sensor alloys provide bare metal thermocouple sensors having advantageous vapor pressure compatibilities and performance characteristics. The compatibility and physical characteristics of the thermocouple sensor alloys of the present invention result in improved emf, temperature properties and thermocouple hot junction performance. The thermocouples formed of the tantalum, rhenium alloys exhibit reliability and performance stability in systems involving high temperatures and vacuums and are adaptable to space propulsion and power systems and nuclear environments.

  14. Logical optical line terminal technologies towards flexible and highly reliable metro- and access-integrated networks

    NASA Astrophysics Data System (ADS)

    Okamoto, Satoru; Sato, Takehiro; Yamanaka, Naoaki

    2017-01-01

    In this paper, flexible and highly reliable metro and access integrated networks with network virtualization and software defined networking technologies will be presented. Logical optical line terminal (L-OLT) technologies and active optical distribution networks (ODNs) are the key to introduce flexibility and high reliability into the metro and access integrated networks. In the Elastic Lambda Aggregation Network (EλAN) project which was started in 2012, a concept of the programmable optical line terminal (P-OLT) has been proposed. A role of the P-OLT is providing multiple network services that have different protocols and quality of service requirements by single OLT box. Accommodated services will be Internet access, mobile front-haul/back-haul, data-center access, and leased line. L-OLTs are configured within the P-OLT box to support the functions required for each network service. Multiple P-OLTs and programmable optical network units (P-ONUs) are connected by the active ODN. Optical access paths which have flexible capacity are set on the ODN to provide network services from L-OLT to logical ONUs (L-ONUs). The L-OLT to L-ONU path on the active ODN provides a logical connection. Therefore, introducing virtualization technologies becomes possible. One example is moving an L-OLT from one P-OLT to another P-OLT like a virtual machine. This movement is called L-OLT migration. The L-OLT migration provides flexible and reliable network functions such as energy saving by aggregating L-OLTs to a limited number of P-OLTs, and network wide optical access path restoration. Other L-OLT virtualization technologies and experimental results will be also discussed in the paper.

  15. High-throughput and reliable protocols for animal microRNA library cloning.

    PubMed

    Xiao, Caide

    2011-01-01

    MicroRNAs are short single-stranded RNA molecules (18-25 nucleotides). Because of their ability to silence gene expressions, they can be used to diagnose and treat tumors. Experimental construction of microRNA libraries was the most important step to identify microRNAs from animal tissues. Although there are many commercial kits with special protocols to construct microRNA libraries, this chapter provides the most reliable, high-throughput, and affordable protocols for microRNA library construction. The high-throughput capability of our protocols came from a double concentration (3 and 15%, thickness 1.5 mm) polyacrylamide gel electrophoresis (PAGE), which could directly extract microRNA-size RNAs from up to 400 μg total RNA (enough for two microRNA libraries). The reliability of our protocols was assured by a third PAGE, which selected PCR products of microRNA-size RNAs ligated with 5' and 3' linkers by a miRCat™ kit. Also, a MathCAD program was provided to automatically search short RNAs inserted between 5' and 3' linkers from thousands of sequencing text files.

  16. A novel approach on accelerated ageing towards reliability optimization of high concentration photovoltaic cells

    NASA Astrophysics Data System (ADS)

    Tsanakas, John A.; Jaffre, Damien; Sicre, Mathieu; Elouamari, Rachid; Vossier, Alexis; de Salins, Jean-Edouard; Bechou, Laurent; Levrier, Bruno; Perona, Arnaud; Dollet, Alain

    2014-09-01

    This paper presents a preliminary study upon a novel approach proposed for highly accelerated ageing and reliability optimization of high concentrating photovoltaic (HCPV) cells and assemblies. The intended approach aims to overcome several limitations of some current accelerated ageing tests (AAT) adopted up today, proposing the use of an alternative experimental set-up for performing faster and more realistic thermal cycles, under real sun, without the involvement of environmental chamber. The study also includes specific characterization techniques, before and after each AAT sequence, which respectively provide the initial and final diagnosis on the condition of the tested sample. The acquired data from these diagnostic/characterization methods are then used as indices to determine both quantitatively and qualitatively the severity of degradation and, thus, the ageing level for each tested HCPV assembly or cell sample. Ultimate goal of such "initial diagnosis - AAT - final diagnosis" sequences is to provide the basis for a future work on the reliability analysis of the main degradation mechanisms and confident prediction of failure propagation in HCPV cells, by means of acceleration factor (AF) and mean-time-to-failure (MTTF) estimations.

  17. Training and Maintaining System-Wide Reliability in Outcome Management.

    PubMed

    Barwick, Melanie A; Urajnik, Diana J; Moore, Julia E

    2014-01-01

    The Child and Adolescent Functional Assessment Scale (CAFAS) is widely used for outcome management, for providing real time client and program level data, and the monitoring of evidence-based practices. Methods of reliability training and the assessment of rater drift are critical for service decision-making within organizations and systems of care. We assessed two approaches for CAFAS training: external technical assistance and internal technical assistance. To this end, we sampled 315 practitioners trained by external technical assistance approach from 2,344 Ontario practitioners who had achieved reliability on the CAFAS. To assess the internal technical assistance approach as a reliable alternative training method, 140 practitioners trained internally were selected from the same pool of certified raters. Reliabilities were high for both practitioners trained by external technical assistance and internal technical assistance approaches (.909-.995, .915-.997, respectively). 1 and 3-year estimates showed some drift on several scales. High and consistent reliabilities over time and training method has implications for CAFAS training of behavioral health care practitioners, and the maintenance of CAFAS as a global outcome management tool in systems of care.

  18. Environmental education curriculum evaluation questionnaire: A reliability and validity study

    NASA Astrophysics Data System (ADS)

    Minner, Daphne Diane

    The intention of this research project was to bridge the gap between social science research and application to the environmental domain through the development of a theoretically derived instrument designed to give educators a template by which to evaluate environmental education curricula. The theoretical base for instrument development was provided by several developmental theories such as Piaget's theory of cognitive development, Developmental Systems Theory, Life-span Perspective, as well as curriculum research within the area of environmental education. This theoretical base fueled the generation of a list of components which were then translated into a questionnaire with specific questions relevant to the environmental education domain. The specific research question for this project is: Can a valid assessment instrument based largely on human development and education theory be developed that reliably discriminates high, moderate, and low quality in environmental education curricula? The types of analyses conducted to answer this question were interrater reliability (percent agreement, Cohen's Kappa coefficient, Pearson's Product-Moment correlation coefficient), test-retest reliability (percent agreement, correlation), and criterion-related validity (correlation). Face validity and content validity were also assessed through thorough reviews. Overall results indicate that 29% of the questions on the questionnaire demonstrated a high level of interrater reliability and 43% of the questions demonstrated a moderate level of interrater reliability. Seventy-one percent of the questions demonstrated a high test-retest reliability and 5% a moderate level. Fifty-five percent of the questions on the questionnaire were reliable (high or moderate) both across time and raters. Only eight questions (8%) did not show either interrater or test-retest reliability. The global overall rating of high, medium, or low quality was reliable across both coders and time, indicating that the questionnaire can discriminate differences in quality of environmental education curricula. Of the 35 curricula evaluated, 6 were high quality, 14 were medium quality and 15 were low quality. The criterion-related validity of the instrument is at current time unable to be established due to the lack of comparable measures or a concretely usable set of multidisciplinary standards. Face and content validity were sufficiently demonstrated.

  19. Design and Analysis of a Flexible, Reliable Deep Space Life Support System

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.

    2012-01-01

    This report describes a flexible, reliable, deep space life support system design approach that uses either storage or recycling or both together. The design goal is to provide the needed life support performance with the required ultra reliability for the minimum Equivalent System Mass (ESM). Recycling life support systems used with multiple redundancy can have sufficient reliability for deep space missions but they usually do not save mass compared to mixed storage and recycling systems. The best deep space life support system design uses water recycling with sufficient water storage to prevent loss of crew if recycling fails. Since the amount of water needed for crew survival is a small part of the total water requirement, the required amount of stored water is significantly less than the total to be consumed. Water recycling with water, oxygen, and carbon dioxide removal material storage can achieve the high reliability of full storage systems with only half the mass of full storage and with less mass than the highly redundant recycling systems needed to achieve acceptable reliability. Improved recycling systems with lower mass and higher reliability could perform better than systems using storage.

  20. Techniques for control of long-term reliability of complex integrated circuits. I - Reliability assurance by test vehicle qualification.

    NASA Technical Reports Server (NTRS)

    Van Vonno, N. W.

    1972-01-01

    Development of an alternate approach to the conventional methods of reliability assurance for large-scale integrated circuits. The product treated is a large-scale T squared L array designed for space applications. The concept used is that of qualification of product by evaluation of the basic processing used in fabricating the product, providing an insight into its potential reliability. Test vehicles are described which enable evaluation of device characteristics, surface condition, and various parameters of the two-level metallization system used. Evaluation of these test vehicles is performed on a lot qualification basis, with the lot consisting of one wafer. Assembled test vehicles are evaluated by high temperature stress at 300 C for short time durations. Stressing at these temperatures provides a rapid method of evaluation and permits a go/no go decision to be made on the wafer lot in a timely fashion.

  1. Nutrition environment measures survey-vending: development, dissemination, and reliability.

    PubMed

    Voss, Carol; Klein, Susan; Glanz, Karen; Clawson, Margaret

    2012-07-01

    Researchers determined a need to develop an instrument to assess the vending machine environment that was comparably reliable and valid to other Nutrition Environment Measures Survey tools and that would provide consistent and comparable data for businesses, schools, and communities. Tool development, reliability testing, and dissemination of the Nutrition Environment Measures Survey-Vending (NEMS-V) involved a collaboration of students, professionals, and community leaders. Interrater reliability testing showed high levels of agreement among trained raters on the products and evaluations of products. NEMS-V can benefit public health partners implementing policy and environmental change initiatives as a part of their community wellness activities. The vending machine project will support a policy calling for state facilities to provide a minimum of 30% of foods and beverages in vending machines as healthy options, based on NEMS-V criteria, which will be used as a model for other businesses.

  2. Critical Assessment of the Foundations of Power Transmission and Distribution Reliability Metrics and Standards.

    PubMed

    Nateghi, Roshanak; Guikema, Seth D; Wu, Yue Grace; Bruss, C Bayan

    2016-01-01

    The U.S. federal government regulates the reliability of bulk power systems, while the reliability of power distribution systems is regulated at a state level. In this article, we review the history of regulating electric service reliability and study the existing reliability metrics, indices, and standards for power transmission and distribution networks. We assess the foundations of the reliability standards and metrics, discuss how they are applied to outages caused by large exogenous disturbances such as natural disasters, and investigate whether the standards adequately internalize the impacts of these events. Our reflections shed light on how existing standards conceptualize reliability, question the basis for treating large-scale hazard-induced outages differently from normal daily outages, and discuss whether this conceptualization maps well onto customer expectations. We show that the risk indices for transmission systems used in regulating power system reliability do not adequately capture the risks that transmission systems are prone to, particularly when it comes to low-probability high-impact events. We also point out several shortcomings associated with the way in which regulators require utilities to calculate and report distribution system reliability indices. We offer several recommendations for improving the conceptualization of reliability metrics and standards. We conclude that while the approaches taken in reliability standards have made considerable advances in enhancing the reliability of power systems and may be logical from a utility perspective during normal operation, existing standards do not provide a sufficient incentive structure for the utilities to adequately ensure high levels of reliability for end-users, particularly during large-scale events. © 2015 Society for Risk Analysis.

  3. [Process design in high-reliability organizations].

    PubMed

    Sommer, K-J; Kranz, J; Steffens, J

    2014-05-01

    Modern medicine is a highly complex service industry in which individual care providers are linked in a complicated network. The complexity and interlinkedness is associated with risks concerning patient safety. Other highly complex industries like commercial aviation have succeeded in maintaining or even increasing its safety levels despite rapidly increasing passenger figures. Standard operating procedures (SOPs), crew resource management (CRM), as well as operational risk evaluation (ORE) are historically developed and trusted parts of a comprehensive and systemic safety program. If medicine wants to follow this quantum leap towards increased patient safety, it must intensively evaluate the results of other high-reliability industries and seek step-by-step implementation after a critical assessment.

  4. An accurate and efficient reliability-based design optimization using the second order reliability method and improved stability transformation method

    NASA Astrophysics Data System (ADS)

    Meng, Zeng; Yang, Dixiong; Zhou, Huanlin; Yu, Bo

    2018-05-01

    The first order reliability method has been extensively adopted for reliability-based design optimization (RBDO), but it shows inaccuracy in calculating the failure probability with highly nonlinear performance functions. Thus, the second order reliability method is required to evaluate the reliability accurately. However, its application for RBDO is quite challenge owing to the expensive computational cost incurred by the repeated reliability evaluation and Hessian calculation of probabilistic constraints. In this article, a new improved stability transformation method is proposed to search the most probable point efficiently, and the Hessian matrix is calculated by the symmetric rank-one update. The computational capability of the proposed method is illustrated and compared to the existing RBDO approaches through three mathematical and two engineering examples. The comparison results indicate that the proposed method is very efficient and accurate, providing an alternative tool for RBDO of engineering structures.

  5. Propulsion controls

    NASA Technical Reports Server (NTRS)

    Harkney, R. D.

    1980-01-01

    Increased system requirements and functional integration with the aircraft have placed an increased demand on control system capability and reliability. To provide these at an affordable cost and weight and because of the rapid advances in electronic technology, hydromechanical systems are being phased out in favor of digital electronic systems. The transition is expected to be orderly from electronic trimming of hydromechanical controls to full authority digital electronic control. Future propulsion system controls will be highly reliable full authority digital electronic with selected component and circuit redundancy to provide the required safety and reliability. Redundancy may include a complete backup control of a different technology for single engine applications. The propulsion control will be required to communicate rapidly with the various flight and fire control avionics as part of an integrated control concept.

  6. Long life electrodes for large-area x-ray generators

    NASA Technical Reports Server (NTRS)

    Rothe, Dietmar E. (Inventor)

    1991-01-01

    This invention is directed to rugged, reliable, and long-life electrodes for use in large-area, high-current-density electron gun and x-ray generators which are employed as contamination-free preionizers for high-energy pulsed gas lasers. The electron source at the cathode is a corona plasma formed at the interface between a conductor, or semiconductor, and a high-permittivity dielectric. Detailed descriptions are provided of a reliable cold plasma cathode, as well as an efficient liquid-cooled electron beam target (anode) and x-ray generator which concentrates the x-ray flux in the direction of an x-ray window.

  7. Enhancing malaria diagnosis through microfluidic cell enrichment and magnetic resonance relaxometry detection

    NASA Astrophysics Data System (ADS)

    Fook Kong, Tian; Ye, Weijian; Peng, Weng Kung; Wei Hou, Han; Marcos; Preiser, Peter Rainer; Nguyen, Nam-Trung; Han, Jongyoon

    2015-06-01

    Despite significant advancements over the years, there remains an urgent need for low cost diagnostic approaches that allow for rapid, reliable and sensitive detection of malaria parasites in clinical samples. Our previous work has shown that magnetic resonance relaxometry (MRR) is a potentially highly sensitive tool for malaria diagnosis. A key challenge for making MRR based malaria diagnostics suitable for clinical testing is the fact that MRR baseline fluctuation exists between individuals, making it difficult to detect low level parasitemia. To overcome this problem, it is important to establish the MRR baseline of each individual while having the ability to reliably determine any changes that are caused by the infection of malaria parasite. Here we show that an approach that combines the use of microfluidic cell enrichment with a saponin lysis before MRR detection can overcome these challenges and provide the basis for a highly sensitive and reliable diagnostic approach of malaria parasites. Importantly, as little as 0.0005% of ring stage parasites can be detected reliably, making this ideally suited for the detection of malaria parasites in peripheral blood obtained from patients. The approaches used here are envisaged to provide a new malaria diagnosis solution in the near future.

  8. Design-for-reliability (DfR) of aerospace electronics: Attributes and challenges

    NASA Astrophysics Data System (ADS)

    Bensoussan, A.; Suhir, E.

    The next generation of multi-beam satellite systems that would be able to provide effective interactive communication services will have to operate within a highly flexible architecture. One option to develop such flexibility is to employ microwaves and/or optoelectronic components and to make them reliable. The use of optoelectronic devices, equipments and systems will result indeed in significant improvement in the state-of-the-art only provided that the new designs will suggest a novel and effective architecture that will combine the merits of good functional performance, satisfactory mechanical (structural) reliability and high cost effectiveness. The obvious challenge is the ability to design and fabricate equipment based on EEE components that would be able to successfully withstand harsh space environments for the entire duration of the mission. It is imperative that the major players in the space industry, such as manufacturers, industrial users, and space agencies, understand the importance and the limits of the achievable quality and reliability of optoelectronic devices operated in harsh environments. It is equally imperative that the physics of possible failures is well understood and, if necessary, minimized, and that adequate Quality Standards are developed and employed. The space community has to identify and to develop the strategic approach for validating optoelectronic products. This should be done with consideration of numerous intrinsic and extrinsic requirements for the systems' performance. When considering a particular next generation optoelectronic space system, the space community needs to address the following major issues: proof of concept for this system, proof of reliability and proof of performance. This should be done with taking into account the specifics of the anticipated application. High operational reliability cannot be left to the prognostics and health monitoring/management (PHM) effort and stage, no matter how important and - ffective such an effort might be. Reliability should be pursued at all the stages of the equipment lifetime: design, product development, manufacturing, burn-in testing and, of course, subsequent PHM after the space apparatus is launched and operated.

  9. Validity and Reliability of a Digital Inclinometer to Assess Knee Joint Position Sense in a Closed Kinetic Chain.

    PubMed

    Romero-Franco, Natalia; Montaño-Munuera, Juan Antonio; Jiménez-Reyes, Pedro

    2017-01-01

    Knee joint position sense (JPS) is a key parameter for optimum performance in many sports but is frequently negatively affected by injuries and/or fatigue during training sessions. Although evaluation of JPS may provide key information to reduce the risk of injury, it often requires expensive and/or complex tools that make monitoring proprioceptive deterioration difficult. To analyze the validity and reliability of a digital inclinometer to measure knee JPS in a closed kinetic chain (CKC). The validity and intertester and intratester reliability of a digital inclinometer for measuring knee JPS were assessed. Biomechanics laboratory. 10 athletes (5 men and 5 women; 26.2 ± 1.3 y, 71.7 ± 12.4 kg; 1.75 ± 0.09 m; 23.5 ± 3.9 kg/m 2 ). Knee JPS was measured in a CKC. Absolute angular error (AAE) of knee JPS in a CKC. Intraclass correlation coefficient (ICC) and standard error of the mean (SEM) were calculated to determine the validity and reliability of the inclinometer. Data showed that the inclinometer had a high level of validity compared with an isokinetic dynamometer (ICC = 1.0, SEM = 1.39, p < 0.001), and there was very good intra- and inter-tester reliability for reading the inclinometer (ICC = 1.0, SEM = 0.85, p < 0.001). Compared with AutoCAD video analysis, inclinometer validity was very high (ICC = 0.980, SEM = 3.46, p < 0.001) for measuring AAE during knee JPS in a CKC. In addition, the intertester reliability of the inclinometer for obtaining AAE was very high (ICC = .994, SEM = 1.67, p < 0.001). The inclinometer provides a valid and reliable method for assessing knee JPS in a CKC. Health and sports professionals could take advantage of this tool to monitor proprioceptive deterioration in athletes.

  10. Standard semiconductor packaging for high-reliability low-cost MEMS applications

    NASA Astrophysics Data System (ADS)

    Harney, Kieran P.

    2005-01-01

    Microelectronic packaging technology has evolved over the years in response to the needs of IC technology. The fundamental purpose of the package is to provide protection for the silicon chip and to provide electrical connection to the circuit board. Major change has been witnessed in packaging and today wafer level packaging technology has further revolutionized the industry. MEMS (Micro Electro Mechanical Systems) technology has created new challenges for packaging that do not exist in standard ICs. However, the fundamental objective of MEMS packaging is the same as traditional ICs, the low cost and reliable presentation of the MEMS chip to the next level interconnect. Inertial MEMS is one of the best examples of the successful commercialization of MEMS technology. The adoption of MEMS accelerometers for automotive airbag applications has created a high volume market that demands the highest reliability at low cost. The suppliers to these markets have responded by exploiting standard semiconductor packaging infrastructures. However, there are special packaging needs for MEMS that cannot be ignored. New applications for inertial MEMS devices are emerging in the consumer space that adds the imperative of small size to the need for reliability and low cost. These trends are not unique to MEMS accelerometers. For any MEMS technology to be successful the packaging must provide the basic reliability and interconnection functions, adding the least possible cost to the product. This paper will discuss the evolution of MEMS packaging in the accelerometer industry and identify the main issues that needed to be addressed to enable the successful commercialization of the technology in the automotive and consumer markets.

  11. Standard semiconductor packaging for high-reliability low-cost MEMS applications

    NASA Astrophysics Data System (ADS)

    Harney, Kieran P.

    2004-12-01

    Microelectronic packaging technology has evolved over the years in response to the needs of IC technology. The fundamental purpose of the package is to provide protection for the silicon chip and to provide electrical connection to the circuit board. Major change has been witnessed in packaging and today wafer level packaging technology has further revolutionized the industry. MEMS (Micro Electro Mechanical Systems) technology has created new challenges for packaging that do not exist in standard ICs. However, the fundamental objective of MEMS packaging is the same as traditional ICs, the low cost and reliable presentation of the MEMS chip to the next level interconnect. Inertial MEMS is one of the best examples of the successful commercialization of MEMS technology. The adoption of MEMS accelerometers for automotive airbag applications has created a high volume market that demands the highest reliability at low cost. The suppliers to these markets have responded by exploiting standard semiconductor packaging infrastructures. However, there are special packaging needs for MEMS that cannot be ignored. New applications for inertial MEMS devices are emerging in the consumer space that adds the imperative of small size to the need for reliability and low cost. These trends are not unique to MEMS accelerometers. For any MEMS technology to be successful the packaging must provide the basic reliability and interconnection functions, adding the least possible cost to the product. This paper will discuss the evolution of MEMS packaging in the accelerometer industry and identify the main issues that needed to be addressed to enable the successful commercialization of the technology in the automotive and consumer markets.

  12. Reliable volumetry of the cervical spinal cord in MS patient follow-up data with cord image analyzer (Cordial).

    PubMed

    Amann, Michael; Pezold, Simon; Naegelin, Yvonne; Fundana, Ketut; Andělová, Michaela; Weier, Katrin; Stippich, Christoph; Kappos, Ludwig; Radue, Ernst-Wilhelm; Cattin, Philippe; Sprenger, Till

    2016-07-01

    Spinal cord (SC) atrophy is an important contributor to the development of disability in many neurological disorders including multiple sclerosis (MS). To assess the spinal cord atrophy in clinical trials and clinical practice, largely automated methods are needed due to the sheer amount of data. Moreover, using these methods in longitudinal trials requires them to deliver highly reliable measurements, enabling comparisons of multiple data sets of the same subject over time. We present a method for SC volumetry using 3D MRI data providing volume measurements for SC sections of fixed length and location. The segmentation combines a continuous max flow approach with SC surface reconstruction that locates the SC boundary based on image voxel intensities. Two cutting planes perpendicular to the SC centerline are determined based on predefined distances to an anatomical landmark, and the cervical SC volume (CSCV) is then calculated in-between these boundaries. The development of the method focused on its application in MRI follow-up studies; the method provides a high scan-rescan reliability, which was tested on healthy subject data. Scan-rescan reliability coefficients of variation (COV) were below 1 %, intra- and interrater COV were even lower (0.1-0.2 %). To show the applicability in longitudinal trials, 3-year follow-up data of 48 patients with a progressive course of MS were assessed. In this cohort, CSCV loss was the only significant predictor of disability progression (p = 0.02). We are, therefore, confident that our method provides a reliable tool for SC volumetry in longitudinal clinical trials.

  13. High-reliability gas-turbine combined-cycle development program: Phase II. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hecht, K.G.; Sanderson, R.A.; Smith, M.J.

    This three-volume report presents the results of Phase II of the multiphase EPRI-sponsored High-Reliability Gas Turbine Combined-Cycle Development Program whose goal is to achieve a highly reliable gas turbine combined-cycle power plant, available by the mid-1980s, which would be an economically attractive baseload generation alternative for the electric utility industry. The Phase II program objective was to prepare the preliminary design of this power plant. This volume presents information of the reliability, availability, and maintainability (RAM) analysis of a representative plant and the preliminary design of the gas turbine, the gas turbine ancillaries, and the balance of plant including themore » steam turbine generator. To achieve the program goals, a gas turbine was incorporated which combined proven reliability characteristics with improved performance features. This gas turbine, designated the V84.3, is the result of a cooperative effort between Kraftwerk Union AG and United Technologies Corporation. Gas turbines of similar design operating in Europe under baseload conditions have demonstrated mean time between failures in excess of 40,000 hours. The reliability characteristics of the gas turbine ancillaries and balance-of-plant equipment were improved through system simplification and component redundancy and by selection of component with inherent high reliability. A digital control system was included with logic, communications, sensor redundancy, and mandual backup. An independent condition monitoring and diagnostic system was also included. Program results provide the preliminary design of a gas turbine combined-cycle baseload power plant. This power plant has a predicted mean time between failure of nearly twice the 3000-hour EPRI goal. The cost of added reliability features is offset by improved performance, which results in a comparable specific cost and an 8% lower cost of electricity compared to present market offerings.« less

  14. Analyzing Reliability and Performance Trade-Offs of HLS-Based Designs in SRAM-Based FPGAs Under Soft Errors

    NASA Astrophysics Data System (ADS)

    Tambara, Lucas Antunes; Tonfat, Jorge; Santos, André; Kastensmidt, Fernanda Lima; Medina, Nilberto H.; Added, Nemitala; Aguiar, Vitor A. P.; Aguirre, Fernando; Silveira, Marcilei A. G.

    2017-02-01

    The increasing system complexity of FPGA-based hardware designs and shortening of time-to-market have motivated the adoption of new designing methodologies focused on addressing the current need for high-performance circuits. High-Level Synthesis (HLS) tools can generate Register Transfer Level (RTL) designs from high-level software programming languages. These tools have evolved significantly in recent years, providing optimized RTL designs, which can serve the needs of safety-critical applications that require both high performance and high reliability levels. However, a reliability evaluation of HLS-based designs under soft errors has not yet been presented. In this work, the trade-offs of different HLS-based designs in terms of reliability, resource utilization, and performance are investigated by analyzing their behavior under soft errors and comparing them to a standard processor-based implementation in an SRAM-based FPGA. Results obtained from fault injection campaigns and radiation experiments show that it is possible to increase the performance of a processor-based system up to 5,000 times by changing its architecture with a small impact in the cross section (increasing up to 8 times), and still increasing the Mean Workload Between Failures (MWBF) of the system.

  15. Bidirectional dc-to-dc Power Converter

    NASA Technical Reports Server (NTRS)

    Griesbach, C. R.

    1986-01-01

    Solid-state, series-resonant converter uses high-voltage thyristors. Converter used either to convert high-voltage, low-current dc power to lowvoltage, high current power or reverse. Taking advantage of newly-available high-voltage thyristors to provide better reliability and efficiency than traditional converters that use vacuum tubes as power switches. New converter essentially maintenance free and provides greatly increased mean time between failures. Attractive in industrial applications whether or not bidirectional capability is required.

  16. Reliability and Measurement Error of Tensiomyography to Assess Mechanical Muscle Function: A Systematic Review.

    PubMed

    Martín-Rodríguez, Saúl; Loturco, Irineu; Hunter, Angus M; Rodríguez-Ruiz, David; Munguia-Izquierdo, Diego

    2017-12-01

    Martín-Rodríguez, S, Loturco, I, Hunter, AM, Rodríguez-Ruiz, D, and Munguia-Izquierdo, D. Reliability and measurement error of tensiomyography to assess mechanical muscle function: A systematic review. J Strength Cond Res 31(12): 3524-3536, 2017-Interest in studying mechanical skeletal muscle function through tensiomyography (TMG) has increased in recent years. This systematic review aimed to (a) report the reliability and measurement error of all TMG parameters (i.e., maximum radial displacement of the muscle belly [Dm], contraction time [Tc], delay time [Td], half-relaxation time [½ Tr], and sustained contraction time [Ts]) and (b) to provide critical reflection on how to perform accurate and appropriate measurements for informing clinicians, exercise professionals, and researchers. A comprehensive literature search was performed of the Pubmed, Scopus, Science Direct, and Cochrane databases up to July 2017. Eight studies were included in this systematic review. Meta-analysis could not be performed because of the low quality of the evidence of some studies evaluated. Overall, the review of the 9 studies involving 158 participants revealed high relative reliability (intraclass correlation coefficient [ICC]) for Dm (0.91-0.99); moderate-to-high ICC for Ts (0.80-0.96), Tc (0.70-0.98), and ½ Tr (0.77-0.93); and low-to-high ICC for Td (0.60-0.98), independently of the evaluated muscles. In addition, absolute reliability (coefficient of variation [CV]) was low for all TMG parameters except for ½ Tr (CV = >20%), whereas measurement error indexes were high for this parameter. In conclusion, this study indicates that 3 of the TMG parameters (Dm, Td, and Tc) are highly reliable, whereas ½ Tr demonstrate insufficient reliability, and thus should not be used in future studies.

  17. RGCA: A Reliable GPU Cluster Architecture for Large-Scale Internet of Things Computing Based on Effective Performance-Energy Optimization

    PubMed Central

    Chen, Qingkui; Zhao, Deyu; Wang, Jingjuan

    2017-01-01

    This paper aims to develop a low-cost, high-performance and high-reliability computing system to process large-scale data using common data mining algorithms in the Internet of Things (IoT) computing environment. Considering the characteristics of IoT data processing, similar to mainstream high performance computing, we use a GPU (Graphics Processing Unit) cluster to achieve better IoT services. Firstly, we present an energy consumption calculation method (ECCM) based on WSNs. Then, using the CUDA (Compute Unified Device Architecture) Programming model, we propose a Two-level Parallel Optimization Model (TLPOM) which exploits reasonable resource planning and common compiler optimization techniques to obtain the best blocks and threads configuration considering the resource constraints of each node. The key to this part is dynamic coupling Thread-Level Parallelism (TLP) and Instruction-Level Parallelism (ILP) to improve the performance of the algorithms without additional energy consumption. Finally, combining the ECCM and the TLPOM, we use the Reliable GPU Cluster Architecture (RGCA) to obtain a high-reliability computing system considering the nodes’ diversity, algorithm characteristics, etc. The results show that the performance of the algorithms significantly increased by 34.1%, 33.96% and 24.07% for Fermi, Kepler and Maxwell on average with TLPOM and the RGCA ensures that our IoT computing system provides low-cost and high-reliability services. PMID:28777325

  18. RGCA: A Reliable GPU Cluster Architecture for Large-Scale Internet of Things Computing Based on Effective Performance-Energy Optimization.

    PubMed

    Fang, Yuling; Chen, Qingkui; Xiong, Neal N; Zhao, Deyu; Wang, Jingjuan

    2017-08-04

    This paper aims to develop a low-cost, high-performance and high-reliability computing system to process large-scale data using common data mining algorithms in the Internet of Things (IoT) computing environment. Considering the characteristics of IoT data processing, similar to mainstream high performance computing, we use a GPU (Graphics Processing Unit) cluster to achieve better IoT services. Firstly, we present an energy consumption calculation method (ECCM) based on WSNs. Then, using the CUDA (Compute Unified Device Architecture) Programming model, we propose a Two-level Parallel Optimization Model (TLPOM) which exploits reasonable resource planning and common compiler optimization techniques to obtain the best blocks and threads configuration considering the resource constraints of each node. The key to this part is dynamic coupling Thread-Level Parallelism (TLP) and Instruction-Level Parallelism (ILP) to improve the performance of the algorithms without additional energy consumption. Finally, combining the ECCM and the TLPOM, we use the Reliable GPU Cluster Architecture (RGCA) to obtain a high-reliability computing system considering the nodes' diversity, algorithm characteristics, etc. The results show that the performance of the algorithms significantly increased by 34.1%, 33.96% and 24.07% for Fermi, Kepler and Maxwell on average with TLPOM and the RGCA ensures that our IoT computing system provides low-cost and high-reliability services.

  19. Determining minimum staffing levels during snowstorms using an integrated simulation, regression, and reliability model.

    PubMed

    Kunkel, Amber; McLay, Laura A

    2013-03-01

    Emergency medical services (EMS) provide life-saving care and hospital transport to patients with severe trauma or medical conditions. Severe weather events, such as snow events, may lead to adverse patient outcomes by increasing call volumes and service times. Adequate staffing levels during such weather events are critical for ensuring that patients receive timely care. To determine staffing levels that depend on weather, we propose a model that uses a discrete event simulation of a reliability model to identify minimum staffing levels that provide timely patient care, with regression used to provide the input parameters. The system is said to be reliable if there is a high degree of confidence that ambulances can immediately respond to a given proportion of patients (e.g., 99 %). Four weather scenarios capture varying levels of snow falling and snow on the ground. An innovative feature of our approach is that we evaluate the mitigating effects of different extrinsic response policies and intrinsic system adaptation. The models use data from Hanover County, Virginia to quantify how snow reduces EMS system reliability and necessitates increasing staffing levels. The model and its analysis can assist in EMS preparedness by providing a methodology to adjust staffing levels during weather events. A key observation is that when it is snowing, intrinsic system adaptation has similar effects on system reliability as one additional ambulance.

  20. Raytheon advanced pulse-tube cryocoolers

    NASA Astrophysics Data System (ADS)

    Conrad, Ted; Yates, Ryan; Kuo, Daniel; Schaefer, Brian; Arnoult, Matt

    2016-05-01

    Since the 1970s, Raytheon has developed, built, tested and integrated high performance cryocoolers. Our versatile designs for single and multi-stage cryocoolers provide reliable operation for temperatures from 10 to 200 Kelvin with power levels ranging from 50 W to nearly 600 W. These cryocoolers incorporate clearance seals, flexure suspensions, hermetic housings and dynamic balancing to provide long service life and reliable operation in all relevant environments. Recently, Raytheon has developed an advanced regenerator technology capable of operating efficiently at high frequencies and outperforming traditional screen regenerators. The Raytheon Advanced Miniature (RAM-100) cryocooler, a flight packaged, high frequency, single stage pulse tube cooler with an integrated surge volume and inertance tube, has been designed for use with this regenerator. Design details and experimentally measured performance of two iterations of the RAM cryocooler are presented in this paper.

  1. Testing the reliability of the Fall Risk Screening Tool in an elderly ambulatory population.

    PubMed

    Fielding, Susan J; McKay, Michael; Hyrkas, Kristiina

    2013-11-01

    To identify and test the reliability of a fall risk screening tool in an ambulatory outpatient clinic. The Fall Risk Screening Tool (Albert Lea Medical Center, MN, USA) was scripted for an interview format. Two interviewers separately screened a convenience sample of 111 patients (age ≥ 65 years) in an ambulatory outpatient clinic in a northeastern US city. The interviewers' scoring of fall risk categories was similar. There was good internal consistency (Cronbach's α = 0.834-0.889) and inter-rater reliability [intra-class correlation coefficients (ICC) = 0.824-0.881] for total, Risk Factor and Client's Health Status subscales. The Physical Environment scores indicated acceptable internal consistency (Cronbach's α = 0.742) and adequate reliability (ICC = 0.688). Two Physical Environment items (furniture and medical equipment condition) had low reliabilities [Kappa (K) = 0.323, P = 0.08; K = -0.078, P = 0.648), respectively. The scripted Fall Risk Screening Tool demonstrated good reliability in this sample. Rewording two Physical Environment items will be considered. A reliable instrument such as the scripted Fall Risk Screening Tool provides a standardised assessment for identifying high fall risk patients. This tool is especially useful because it assesses personal, behavioural and environmental factors specific to community-dwelling patients; the interview format also facilitates patient-provider interaction. © 2013 John Wiley & Sons Ltd.

  2. Safety evaluation of high-speed rail bogie concepts.

    DOT National Transportation Integrated Search

    2013-10-01

    The study defines the basic design concepts required to provide a safe, reliable, high-speed bogie for the next generation PRIIA passenger locomotive. The requirements and conditions for the U.S. market create unique design challenges that currently ...

  3. High rate concatenated coding systems using bandwidth efficient trellis inner codes

    NASA Technical Reports Server (NTRS)

    Deng, Robert H.; Costello, Daniel J., Jr.

    1989-01-01

    High-rate concatenated coding systems with bandwidth-efficient trellis inner codes and Reed-Solomon (RS) outer codes are investigated for application in high-speed satellite communication systems. Two concatenated coding schemes are proposed. In one the inner code is decoded with soft-decision Viterbi decoding, and the outer RS code performs error-correction-only decoding (decoding without side information). In the other, the inner code is decoded with a modified Viterbi algorithm, which produces reliability information along with the decoded output. In this algorithm, path metrics are used to estimate the entire information sequence, whereas branch metrics are used to provide reliability information on the decoded sequence. This information is used to erase unreliable bits in the decoded output. An errors-and-erasures RS decoder is then used for the outer code. The two schemes have been proposed for high-speed data communication on NASA satellite channels. The rates considered are at least double those used in current NASA systems, and the results indicate that high system reliability can still be achieved.

  4. Advanced propulsion engine assessment based on a cermet reactor

    NASA Technical Reports Server (NTRS)

    Parsley, Randy C.

    1993-01-01

    A preferred Pratt & Whitney conceptual Nuclear Thermal Rocket Engine (NTRE) has been designed based on the fundamental NASA priorities of safety, reliability, cost, and performance. The basic philosophy underlying the design of the XNR2000 is the utilization of the most reliable form of ultrahigh temperature nuclear fuel and development of a core configuration which is optimized for uniform power distribution, operational flexibility, power maneuverability, weight, and robustness. The P&W NTRE system employs a fast spectrum, cermet fueled reactor configured in an expander cycle to ensure maximum operational safety. The cermet fuel form provides retention of fuel and fission products as well as high strength. A high level of confidence is provided by benchmark analysis and independent evaluations.

  5. The Effect of Incorrect Reliability Information on Expectations, Perceptions, and Use of Automation.

    PubMed

    Barg-Walkow, Laura H; Rogers, Wendy A

    2016-03-01

    We examined how providing artificially high or low statements about automation reliability affected expectations, perceptions, and use of automation over time. One common method of introducing automation is providing explicit statements about the automation's capabilities. Research is needed to understand how expectations from such introductions affect perceptions and use of automation. Explicit-statement introductions were manipulated to set higher-than (90%), same-as (75%), or lower-than (60%) levels of expectations in a dual-task scenario with 75% reliable automation. Two experiments were conducted to assess expectations, perceptions, compliance, reliance, and task performance over (a) 2 days and (b) 4 days. The baseline assessments showed initial expectations of automation reliability matched introduced levels of expectation. For the duration of each experiment, the lower-than groups' perceptions were lower than the actual automation reliability. However, the higher-than groups' perceptions were no different from actual automation reliability after Day 1 in either study. There were few differences between groups for automation use, which generally stayed the same or increased with experience using the system. Introductory statements describing artificially low automation reliability have a long-lasting impact on perceptions about automation performance. Statements including incorrect automation reliability do not appear to affect use of automation. Introductions should be designed according to desired outcomes for expectations, perceptions, and use of the automation. Low expectations have long-lasting effects. © 2015, Human Factors and Ergonomics Society.

  6. The Iridium (tm) system: Personal communications anytime, anyplace

    NASA Technical Reports Server (NTRS)

    Hatlelid, John E.; Casey, Larry

    1993-01-01

    The Iridium system is designed to provide handheld personal communications between diverse locations around the world at any time and without prior knowledge of the location of the personal units. This paper provides an overview of the system, the services it provides, its operation, and an overview of the commercial practices and relatively high volume satellite production techniques which will make the system cost effective. A constellation of 66 satellites will provide an orbiting, spherical-shell, infrastructure for this global calling capability. The satellites act as tall cellular towers and allow convenient operation for portable handheld telephones. The system will provide a full range of services including voice, paging, data, geolocation, and fax capabilities. Motorola is a world leader in the production of high volume, high quality, reliable telecommunications hardware. One of Iridium's goals is to apply these production techniques to high reliability space hardware. Concurrent engineering, high performance work teams, advanced manufacturing technologies, and improved assembly and test methods are some of the techniques that will keep the Iridium system cost effective. Mobile, global, flexible personal communications are coming that will allow anyone to call or receive a call from/to anyplace at anytime. The Iridium system will provide communications where none exist today. This connectivity will allow increased information transfer, open new markets for various business endeavors, and in general increase productivity and development.

  7. The Iridium (tm) system: Personal communications anytime, anyplace

    NASA Astrophysics Data System (ADS)

    Hatlelid, John E.; Casey, Larry

    The Iridium system is designed to provide handheld personal communications between diverse locations around the world at any time and without prior knowledge of the location of the personal units. This paper provides an overview of the system, the services it provides, its operation, and an overview of the commercial practices and relatively high volume satellite production techniques which will make the system cost effective. A constellation of 66 satellites will provide an orbiting, spherical-shell, infrastructure for this global calling capability. The satellites act as tall cellular towers and allow convenient operation for portable handheld telephones. The system will provide a full range of services including voice, paging, data, geolocation, and fax capabilities. Motorola is a world leader in the production of high volume, high quality, reliable telecommunications hardware. One of Iridium's goals is to apply these production techniques to high reliability space hardware. Concurrent engineering, high performance work teams, advanced manufacturing technologies, and improved assembly and test methods are some of the techniques that will keep the Iridium system cost effective. Mobile, global, flexible personal communications are coming that will allow anyone to call or receive a call from/to anyplace at anytime. The Iridium system will provide communications where none exist today. This connectivity will allow increased information transfer, open new markets for various business endeavors, and in general increase productivity and development.

  8. Validity and Reliability of Accelerometers in Patients With COPD: A SYSTEMATIC REVIEW.

    PubMed

    Gore, Shweta; Blackwood, Jennifer; Guyette, Mary; Alsalaheen, Bara

    2018-05-01

    Reduced physical activity is associated with poor prognosis in chronic obstructive pulmonary disease (COPD). Accelerometers have greatly improved quantification of physical activity by providing information on step counts, body positions, energy expenditure, and magnitude of force. The purpose of this systematic review was to compare the validity and reliability of accelerometers used in patients with COPD. An electronic database search of MEDLINE and CINAHL was performed. Study quality was assessed with the Strengthening the Reporting of Observational Studies in Epidemiology checklist while methodological quality was assessed using the modified Quality Appraisal Tool for Reliability Studies. The search yielded 5392 studies; 25 met inclusion criteria. The SenseWear Pro armband reported high criterion validity under controlled conditions (r = 0.75-0.93) and high reliability (ICC = 0.84-0.86) for step counts. The DynaPort MiniMod demonstrated highest concurrent validity for step count using both video and manual methods. Validity of the SenseWear Pro armband varied between studies especially in free-living conditions, slower walking speeds, and with addition of weights during gait. A high degree of variability was found in the outcomes used and statistical analyses performed between studies, indicating a need for further studies to measure reliability and validity of accelerometers in COPD. The SenseWear Pro armband is the most commonly used accelerometer in COPD, but measurement properties are limited by gait speed variability and assistive device use. DynaPort MiniMod and Stepwatch accelerometers demonstrated high validity in patients with COPD but lack reliability data.

  9. Benchmarks and Reliable DFT Results for Spin Gaps of Small Ligand Fe(II) Complexes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Song, Suhwan; Kim, Min-Cheol; Sim, Eunji

    2017-05-01

    All-electron fixed-node diffusion Monte Carlo provides benchmark spin gaps for four Fe(II) octahedral complexes. Standard quantum chemical methods (semilocal DFT and CCSD(T)) fail badly for the energy difference between their high- and low-spin states. Density-corrected DFT is both significantly more accurate and reliable and yields a consistent prediction for the Fe-Porphyrin complex

  10. An Investigation of the Generalizability of Medical School Grades.

    PubMed

    Kreiter, Clarence D; Ferguson, Kristi J

    2016-01-01

    Construct/Background: Medical school grades are currently unstandardized, and their level of reliability is unknown. This means their usefulness for reporting on student achievement is also not well documented. This study investigates grade reliability within 1 medical school. Generalizability analyses are conducted on grades awarded. Grades from didactic and clerkship-based courses were treated as 2 levels of a fixed facet within a univariate mixed model. Grades from within the 2 levels (didactic and clerkship) were also entered in a multivariate generalizability study. Grades from didactic courses were shown to produce a highly reliable mean score (G = .79) when averaged over as few as 5 courses. Although the universe score correlation between didactic and clerkship courses was high (r = .80), the clerkship courses required almost twice as many grades to reach a comparable level of reliability. When grades were converted to a Pass/Fail metric, almost all information contained in the grades was lost. Although it has been suggested that the imprecision of medical school grades precludes their use as a reliable indicator of student achievement, these results suggest otherwise. While it is true that a Pass/Fail system of grading provides very little information about a student's level of performance, a multi-tiered grading system was shown to be a highly reliable indicator of student achievement within the medical school. Although grades awarded during the first 2 didactic years appear to be more reliable than clerkship grades, both yield useful information about student performance within the medical college.

  11. Regulation of transmission line capacity and reliability in electric networks

    NASA Astrophysics Data System (ADS)

    Celebi, Metin

    This thesis is composed of two essays that analyze the incentives and optimal regulation of a monopolist line owner in providing capacity and reliability. Similar analyses in the economic literature resulted in under-investment by an unregulated line owner when line reliability was treated as an exogenous variable. However, reliability should be chosen on the basis of economic principles as well, taking into account not only engineering principles but also the preferences of electricity users. When reliability is treated as a choice variable, both over- and under-investment by the line owner becomes possible. The result depends on the cross-cost elasticity of line construction and on the interval in which the optimal choices of capacity take place. We present some sufficient conditions that lead to definite results about the incentives of the line owner. We also characterize the optimal regulation of the line owner under incomplete information. Our analysis shows that the existence of a line is justified for the social planner when the reliability of other lines on the network is not too high, or when the marginal cost of generation at the expensive generating plant is high. The expectation of higher demand in the future makes the regulator less likely to build the line if it will be congested and reliability of other lines is high enough. It is always optimal to have a congested line under complete information, but not necessarily under incomplete information.

  12. Redundant disk arrays: Reliable, parallel secondary storage. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Gibson, Garth Alan

    1990-01-01

    During the past decade, advances in processor and memory technology have given rise to increases in computational performance that far outstrip increases in the performance of secondary storage technology. Coupled with emerging small-disk technology, disk arrays provide the cost, volume, and capacity of current disk subsystems, by leveraging parallelism, many times their performance. Unfortunately, arrays of small disks may have much higher failure rates than the single large disks they replace. Redundant arrays of inexpensive disks (RAID) use simple redundancy schemes to provide high data reliability. The data encoding, performance, and reliability of redundant disk arrays are investigated. Organizing redundant data into a disk array is treated as a coding problem. Among alternatives examined, codes as simple as parity are shown to effectively correct single, self-identifying disk failures.

  13. Calibration and testing of selected portable flowmeters for use on large irrigation systems

    USGS Publications Warehouse

    Luckey, Richard R.; Heimes, Frederick J.; Gaggiani, Neville G.

    1980-01-01

    Existing methods for measuring discharge of irrigation systems in the High Plains region are not suitable to provide the pumpage data required by the High Plains Regional Aquifer System Analysis. Three portable flowmeters that might be suitable for obtaining fast and accurate discharge measure-ments on large irrigation systems were tested during 1979 under both laboratory and field conditions: propeller type gated-pipe meter, a Doppler meter, and a transient-time meter.The gated-pipe meter was found to be difficult to use and sensitive to particulate matter in the fluid. The Doppler meter, while easy to use, would not function suitably on steel pipe 6 inches or larger in diameter, or on aluminum pipe larger than 8 inches in diameter. The transient-time meter was more difficult to use than the other two meters; however, this instrument provided a high degree of accuracy and reliability under a variety of conditions. Of the three meters tested, only the transient-time meter was found to be suitable for providing reliable discharge measurements on the variety of irrigation systems used in the High Plains region.

  14. Optimizing the Reliability and Performance of Service Composition Applications with Fault Tolerance in Wireless Sensor Networks

    PubMed Central

    Wu, Zhao; Xiong, Naixue; Huang, Yannong; Xu, Degang; Hu, Chunyang

    2015-01-01

    The services composition technology provides flexible methods for building service composition applications (SCAs) in wireless sensor networks (WSNs). The high reliability and high performance of SCAs help services composition technology promote the practical application of WSNs. The optimization methods for reliability and performance used for traditional software systems are mostly based on the instantiations of software components, which are inapplicable and inefficient in the ever-changing SCAs in WSNs. In this paper, we consider the SCAs with fault tolerance in WSNs. Based on a Universal Generating Function (UGF) we propose a reliability and performance model of SCAs in WSNs, which generalizes a redundancy optimization problem to a multi-state system. Based on this model, an efficient optimization algorithm for reliability and performance of SCAs in WSNs is developed based on a Genetic Algorithm (GA) to find the optimal structure of SCAs with fault-tolerance in WSNs. In order to examine the feasibility of our algorithm, we have evaluated the performance. Furthermore, the interrelationships between the reliability, performance and cost are investigated. In addition, a distinct approach to determine the most suitable parameters in the suggested algorithm is proposed. PMID:26561818

  15. The Healthy Brain Network Serial Scanning Initiative: a resource for evaluating inter-individual differences and their reliabilities across scan conditions and sessions

    PubMed Central

    O’Connor, David; Potler, Natan Vega; Kovacs, Meagan; Xu, Ting; Ai, Lei; Pellman, John; Vanderwal, Tamara; Parra, Lucas C.; Cohen, Samantha; Ghosh, Satrajit; Escalera, Jasmine; Grant-Villegas, Natalie; Osman, Yael; Bui, Anastasia; Craddock, R. Cameron

    2017-01-01

    Abstract Background: Although typically measured during the resting state, a growing literature is illustrating the ability to map intrinsic connectivity with functional MRI during task and naturalistic viewing conditions. These paradigms are drawing excitement due to their greater tolerability in clinical and developing populations and because they enable a wider range of analyses (e.g., inter-subject correlations). To be clinically useful, the test-retest reliability of connectivity measured during these paradigms needs to be established. This resource provides data for evaluating test-retest reliability for full-brain connectivity patterns detected during each of four scan conditions that differ with respect to level of engagement (rest, abstract animations, movie clips, flanker task). Data are provided for 13 participants, each scanned in 12 sessions with 10 minutes for each scan of the four conditions. Diffusion kurtosis imaging data was also obtained at each session. Findings: Technical validation and demonstrative reliability analyses were carried out at the connection-level using the Intraclass Correlation Coefficient and at network-level representations of the data using the Image Intraclass Correlation Coefficient. Variation in intrinsic functional connectivity across sessions was generally found to be greater than that attributable to scan condition. Between-condition reliability was generally high, particularly for the frontoparietal and default networks. Between-session reliabilities obtained separately for the different scan conditions were comparable, though notably lower than between-condition reliabilities. Conclusions: This resource provides a test-bed for quantifying the reliability of connectivity indices across subjects, conditions and time. The resource can be used to compare and optimize different frameworks for measuring connectivity and data collection parameters such as scan length. Additionally, investigators can explore the unique perspectives of the brain's functional architecture offered by each of the scan conditions. PMID:28369458

  16. Inter- and intrarater reliability of the Chicago Classification in pediatric high-resolution esophageal manometry recordings.

    PubMed

    Singendonk, M M J; Smits, M J; Heijting, I E; van Wijk, M P; Nurko, S; Rosen, R; Weijenborg, P W; Abu-Assi, R; Hoekman, D R; Kuizenga-Wessel, S; Seiboth, G; Benninga, M A; Omari, T I; Kritas, S

    2015-02-01

    The Chicago Classification (CC) facilitates interpretation of high-resolution manometry (HRM) recordings. Application of this adult based algorithm to the pediatric population is unknown. We therefore assessed intra and interrater reliability of software-based CC diagnosis in a pediatric cohort. Thirty pediatric solid state HRM recordings (13M; mean age 12.1 ± 5.1 years) assessing 10 liquid swallows per patient were analyzed twice by 11 raters (six experts, five non-experts). Software-placed anatomical landmarks required manual adjustment or removal. Integrated relaxation pressure (IRP4s), distal contractile integral (DCI), contractile front velocity (CFV), distal latency (DL) and break size (BS), and an overall CC diagnosis were software-generated. In addition, raters provided their subjective CC diagnosis. Reliability was calculated with Cohen's and Fleiss' kappa (κ) and intraclass correlation coefficient (ICC). Intra- and interrater reliability of software-generated CC diagnosis after manual adjustment of landmarks was substantial (mean κ = 0.69 and 0.77 respectively) and moderate-substantial for subjective CC diagnosis (mean κ = 0.70 and 0.58 respectively). Reliability of both software-generated and subjective diagnosis of normal motility was high (κ = 0.81 and κ = 0.79). Intra- and interrater reliability were excellent for IRP4s, DCI, and BS. Experts had higher interrater reliability than non-experts for DL (ICC = 0.65 vs ICC = 0.36 respectively) and the software-generated diagnosis diffuse esophageal spasm (DES, κ = 0.64 vs κ = 0.30). Among experts, the reliability for the subjective diagnosis of achalasia and esophageal gastric junction outflow obstruction was moderate-substantial (κ = 0.45-0.82). Inter- and intrarater reliability of software-based CC diagnosis of pediatric HRM recordings was high overall. However, experience was a factor influencing the diagnosis of some motility disorders, particularly DES and achalasia. © 2014 John Wiley & Sons Ltd.

  17. MOLAR: Modular Linux and Adaptive Runtime Support for HEC OS/R Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frank Mueller

    2009-02-05

    MOLAR is a multi-institution research effort that concentrates on adaptive, reliable,and efficient operating and runtime system solutions for ultra-scale high-end scientific computing on the next generation of supercomputers. This research addresses the challenges outlined by the FAST-OS - forum to address scalable technology for runtime and operating systems --- and HECRTF --- high-end computing revitalization task force --- activities by providing a modular Linux and adaptable runtime support for high-end computing operating and runtime systems. The MOLAR research has the following goals to address these issues. (1) Create a modular and configurable Linux system that allows customized changes based onmore » the requirements of the applications, runtime systems, and cluster management software. (2) Build runtime systems that leverage the OS modularity and configurability to improve efficiency, reliability, scalability, ease-of-use, and provide support to legacy and promising programming models. (3) Advance computer reliability, availability and serviceability (RAS) management systems to work cooperatively with the OS/R to identify and preemptively resolve system issues. (4) Explore the use of advanced monitoring and adaptation to improve application performance and predictability of system interruptions. The overall goal of the research conducted at NCSU is to develop scalable algorithms for high-availability without single points of failure and without single points of control.« less

  18. Developing Ultra Reliable Life Support for the Moon and Mars

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.

    2009-01-01

    Recycling life support systems can achieve ultra reliability by using spares to replace failed components. The added mass for spares is approximately equal to the original system mass, provided the original system reliability is not very low. Acceptable reliability can be achieved for the space shuttle and space station by preventive maintenance and by replacing failed units, However, this maintenance and repair depends on a logistics supply chain that provides the needed spares. The Mars mission must take all the needed spares at launch. The Mars mission also must achieve ultra reliability, a very low failure rate per hour, since it requires years rather than weeks and cannot be cut short if a failure occurs. Also, the Mars mission has a much higher mass launch cost per kilogram than shuttle or station. Achieving ultra reliable space life support with acceptable mass will require a well-planned and extensive development effort. Analysis must define the reliability requirement and allocate it to subsystems and components. Technologies, components, and materials must be designed and selected for high reliability. Extensive testing is needed to ascertain very low failure rates. Systems design should segregate the failure causes in the smallest, most easily replaceable parts. The systems must be designed, produced, integrated, and tested without impairing system reliability. Maintenance and failed unit replacement should not introduce any additional probability of failure. The overall system must be tested sufficiently to identify any design errors. A program to develop ultra reliable space life support systems with acceptable mass must start soon if it is to produce timely results for the moon and Mars.

  19. High reliability linear drive device for artificial hearts

    NASA Astrophysics Data System (ADS)

    Ji, Jinghua; Zhao, Wenxiang; Liu, Guohai; Shen, Yue; Wang, Fangqun

    2012-04-01

    In this paper, a new high reliability linear drive device, termed as stator-permanent-magnet tubular oscillating actuator (SPM-TOA), is proposed for artificial hearts (AHs). The key is to incorporate the concept of two independent phases into this linear AH device, hence achieving high reliability operation. The fault-tolerant teeth are employed to provide the desired decoupling phases in magnetic circuit. Also, as the magnets and the coils are located in the stator, the proposed SPM-TOA takes the definite advantages of robust mover and direct-drive capability. By using the time-stepping finite element method, the electromagnetic characteristics of the proposed SPM-TOA are analyzed, including magnetic field distributions, flux linkages, back- electromotive forces (back-EMFs) self- and mutual inductances, as well as cogging and thrust forces. The results confirm that the proposed SPM-TOA meets the dimension, weight, and force requirements of the AH drive device.

  20. Recombination of open-f-shell tungsten ions

    NASA Astrophysics Data System (ADS)

    Krantz, C.; Badnell, N. R.; Müller, A.; Schippers, S.; Wolf, A.

    2017-03-01

    We review experimental and theoretical efforts aimed at a detailed understanding of the recombination of electrons with highly charged tungsten ions characterised by an open 4f sub-shell. Highly charged tungsten occurs as a plasma contaminant in ITER-like tokamak experiments, where it acts as an unwanted cooling agent. Modelling of the charge state populations in a plasma requires reliable thermal rate coefficients for charge-changing electron collisions. The electron recombination of medium-charged tungsten species with open 4f sub-shells is especially challenging to compute reliably. Storage-ring experiments have been conducted that yielded recombination rate coefficients at high energy resolution and well-understood systematics. Significant deviations compared to simplified, but prevalent, computational models have been found. A new class of ab initio numerical calculations has been developed that provides reliable predictions of the total plasma recombination rate coefficients for these ions.

  1. HiRel: Hybrid Automated Reliability Predictor (HARP) integrated reliability tool system, (version 7.0). Volume 3: HARP Graphics Oriented (GO) input user's guide

    NASA Technical Reports Server (NTRS)

    Bavuso, Salvatore J.; Rothmann, Elizabeth; Mittal, Nitin; Koppen, Sandra Howell

    1994-01-01

    The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of highly reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed at the outset to be compatible with most computing platforms and operating systems, and some programs have been beta tested within the aerospace community for over 8 years. This document is a user's guide for the HiRel graphical preprocessor Graphics Oriented (GO) program. GO is a graphical user interface for the HARP engine that enables the drawing of reliability/availability models on a monitor. A mouse is used to select fault tree gates or Markov graphical symbols from a menu for drawing.

  2. Magnetic refrigeration for maser amplifier cooling

    NASA Technical Reports Server (NTRS)

    Johnson, D. L.

    1982-01-01

    The development of a multifrequency upconverter-maser system for the DSN has created the need to develop a closed-cycle refrigerator (CCR) capable of providing more than 3 watts of refrigeration capability at 4.5 K. In addition, operating concerns such as the high cost of electrical power consumption and the loss of maser operation due to CCR failures require that improvements be made to increase the efficiency and reliability of the CCR. One refrigeration method considered is the replacement of the Joule-Thomson expansion circuit with a magnetic refrigeration. Magnetic refrigerators can provide potentially reliable and highly efficient refrigeration at a variety of temperature ranges and cooling power. The concept of magnetic refrigeration is summarized and a literature review of existing magnetic refrigerator designs which have been built and tested and that may also be considered as possibilities as a 4 K to 15 K magnetic refrigeration stage for the DSN closed-cycle refrigerator is provided.

  3. To the question about the states of workability for automatic control systems with complicated structure

    NASA Astrophysics Data System (ADS)

    Kuznetsov, P. A.; Kovalev, I. V.; Losev, V. V.; Kalinin, A. O.; Murygin, A. V.

    2016-04-01

    The article discusses the reliability of automated control systems. Analyzes the approach to the classification systems for health States. This approach can be as traditional binary approach, operating with the concept of "serviceability", and other variants of estimation of the system state. This article provides one such option, providing selective evaluation of components for the reliability of the entire system. Introduced description of various automatic control systems and their elements from the point of view of health and risk, mathematical method of determining the transition object from state to state, they differ from each other in the implementation of the objective function. Explores the interplay of elements in different States, the aggregate state of the elements connected in series or in parallel. Are the tables of various logic States and the principles of their calculation in series and parallel connection. Through simulation the proposed approach is illustrated by finding the probability of getting into the system state data in parallel and serially connected elements, with their different probabilities of moving from state to state. In general, the materials of article will be useful for analyzing of the reliability the automated control systems and engineering of the highly-reliable systems. Thus, this mechanism to determine the State of the system provides more detailed information about it and allows a selective approach to the reliability of the system as a whole. Detailed results when assessing the reliability of the automated control systems allows the engineer to make an informed decision when designing means of improving reliability.

  4. Inter-day Reliability of the IDEEA Activity Monitor for Measuring Movement and Non-Movement Behaviors in Older Adults.

    PubMed

    de la Cámara, Miguel Ángel; Higueras-Fresnillo, Sara; Martinez-Gomez, David; Veiga, Oscar L

    2018-05-29

    The inter-day reliability of the Intelligent Device for Energy Expenditure and Activity (IDEEA) has not been studied to date. The study purpose was to examine the inter-day variability and reliability on two consecutive days collected with the IDEEA, as well as to predict the number of days needed to provide a reliable estimate of several movement (walking and climbing stairs) and non-movement behaviors (lying, reclining, sitting) and standing in older adults. The sample included 126 older adults (74 women) who wore the IDEEA for 48-h. Results showed low variability between the two days and its reliability was from moderate (ICC=0.34) to high (ICC=0.80) in most of movement and non-movement behaviors analyzed. The Bland-Altman plots showed a high-moderate agreement between days and the Spearman-Brown formula estimated ranged from 1.2 and 9.1 days of monitoring with the IDEEA are needed to achieve ICCs≥0.70 in older adults for sitting and climbing stairs, respectively.

  5. Camera-tracking gaming control device for evaluation of active wrist flexion and extension.

    PubMed

    Shefer Eini, Dalit; Ratzon, Navah Z; Rizzo, Albert A; Yeh, Shih-Ching; Lange, Belinda; Yaffe, Batia; Daich, Alexander; Weiss, Patrice L; Kizony, Rachel

    Cross sectional. Measuring wrist range of motion (ROM) is an essential procedure in hand therapy clinics. To test the reliability and validity of a dynamic ROM assessment, the Camera Wrist Tracker (CWT). Wrist flexion and extension ROM of 15 patients with distal radius fractures and 15 matched controls were assessed with the CWT and with a universal goniometer. One-way model intraclass correlation coefficient analysis indicated high test-retest reliability for extension (ICC = 0.92) and moderate reliability for flexion (ICC = 0.49). Standard error for extension was 2.45° and for flexion was 4.07°. Repeated-measures analysis revealed a significant main effect for group; ROM was greater in the control group (F[1, 28] = 47.35; P < .001). The concurrent validity of the CWT was partially supported. The results indicate that the CWT may provide highly reliable scores for dynamic wrist extension ROM, and moderately reliable scores for flexion, in people recovering from a distal radius fracture. N/A. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  6. Real-time sonoelastography using an external reference material: test-retest reliability of healthy Achilles tendons.

    PubMed

    Schneebeli, Alessandro; Del Grande, Filippo; Vincenzo, Gabriele; Cescon, Corrado; Clijsen, Ron; Biordi, Fulvio; Barbero, Marco

    2016-08-01

    To establish the test-retest reliability of sonoelastography (SE) on healthy Achilles tendons in contracted and relaxed states using an external reference system. Forty-eight Achilles tendons from 24 healthy volunteers were assessed using ultrasound and real-time SE with an external reference material. Tendons were analyzed under relaxed and contracted conditions. Strain ratios between the tendons and the reference material were calculated. The intraclass correlation coefficient (ICC2.k) and Bland-Altman plot were used to assess test-retest reliability. The reliability of SE measurements under relaxed conditions ranged from high to very high, with an ICC2.k of 0.84 (95 % CI: 0.64-0.92) for reference material, 0.91 (95 % CI: 0.83-0.95) for Achilles tendons and 0.95 (95 % CI: 0.91-0.97) for Kager fat pads (KFP). The ICC2.k value for skin was 0.30 (95 % CI: -0.26 to 0.61). Reliability for measurements in the contracted state ranged from high to very high, with an ICC2.k of 0.93 (95 % CI: 0.87-0.96) for reference material, 0.72 (95 % CI: 0.50-0.84) for skin, 0.93 (95 % CI: 0.87-0.96) for Achilles tendons, and 0.81 (95 % CI: 0.66-0.89) for KFP. Reliability of the strain ratio (tendon/reference) under relaxed conditions was high with an ICC2.k of 0.87 (95 % CI: 0.75-0.93), and in the contracted state, it was very high with an ICC2.k of 0.94 (95 % CI: 0.90-0.97). Sonoelastography using an external reference material is a reliable and simple technique for the assessment of the elasticity of healthy Achilles tendons. The use of an external material as a reference, along with strain ratios, could provide a quantitative measure of elasticity.

  7. High-reliability gas-turbine combined-cycle development program: Phase II, Volume 3. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hecht, K.G.; Sanderson, R.A.; Smith, M.J.

    This three-volume report presents the results of Phase II of the multiphase EPRI-sponsored High-Reliability Gas Turbine Combined-Cycle Development Program whose goal is to achieve a highly reliable gas turbine combined-cycle power plant, available by the mid-1980s, which would be an economically attractive baseload generation alternative for the electric utility industry. The Phase II program objective was to prepare the preliminary design of this power plant. The power plant was addressed in three areas: (1) the gas turbine, (2) the gas turbine ancillaries, and (3) the balance of plant including the steam turbine generator. To achieve the program goals, a gasmore » turbine was incorporated which combined proven reliability characteristics with improved performance features. This gas turbine, designated the V84.3, is the result of a cooperative effort between Kraftwerk Union AG and United Technologies Corporation. Gas turbines of similar design operating in Europe under baseload conditions have demonstrated mean time between failures in excess of 40,000. The reliability characteristics of the gas turbine ancillaries and balance-of-plant equipment were improved through system simplification and component redundancy and by selection of component with inherent high reliability. A digital control system was included with logic, communications, sensor redundancy, and manual backup. An independent condition monitoring and diagnostic system was also included. Program results provide the preliminary design of a gas turbine combined-cycle baseload power plant. This power plant has a predicted mean time between failure of nearly twice the 3000-h EPRI goal. The cost of added reliability features is offset by improved performance, which results in a comparable specific cost and an 8% lower cost of electricty compared to present market offerings.« less

  8. DRS: Derivational Reasoning System

    NASA Technical Reports Server (NTRS)

    Bose, Bhaskar

    1995-01-01

    The high reliability requirements for airborne systems requires fault-tolerant architectures to address failures in the presence of physical faults, and the elimination of design flaws during the specification and validation phase of the design cycle. Although much progress has been made in developing methods to address physical faults, design flaws remain a serious problem. Formal methods provides a mathematical basis for removing design flaws from digital systems. DRS (Derivational Reasoning System) is a formal design tool based on advanced research in mathematical modeling and formal synthesis. The system implements a basic design algebra for synthesizing digital circuit descriptions from high level functional specifications. DRS incorporates an executable specification language, a set of correctness preserving transformations, verification interface, and a logic synthesis interface, making it a powerful tool for realizing hardware from abstract specifications. DRS integrates recent advances in transformational reasoning, automated theorem proving and high-level CAD synthesis systems in order to provide enhanced reliability in designs with reduced time and cost.

  9. NASA-DoD Lead-Free Electronics Project

    NASA Technical Reports Server (NTRS)

    Kessel, Kurt R.

    2009-01-01

    In response to concerns about risks from lead-free induced faults to high reliability products, NASA has initiated a multi-year project to provide manufacturers and users with data to clarify the risks of lead-free materials in their products. The project will also be of interest to component manufacturers supplying to high reliability markets. The project was launched in November 2006. The primary technical objective of the project is to undertake comprehensive testing to generate information on failure modes/criteria to better understand the reliability of: - Packages (e.g., TSOP, BOA, PDIP) assembled and reworked with solder interconnects consisting of lead-free alloys - Packages (e.g., TSOP, BOA, PDIP) assembled and reworked with solder interconnects consisting of mixed alloys, lead component finish/lead-free solder and lead-free component finish/SnPb solder.

  10. NASA-DoD Lead-Free Electronics Project

    NASA Technical Reports Server (NTRS)

    Kessel, Kurt R.

    2009-01-01

    In response to concerns about risks from lead-free induced faults to high reliability products, NASA has initiated a multi-year project to provide manufacturers and users with data to clarify the risks of lead-free materials in their products. The project will also be of interest to component manufacturers supplying to high reliability markets. The project was launched in November 2006. The primary technical objective of the project is to undertake comprehensive testing to generate information on failure modes/criteria to better understand the reliability of: - Packages (e.g., TSOP, BGA, PDIP) assembled and reworked with solder interconnects consisting of lead-free alloys - Packages (e.g., TSOP, BGA, PDIP) assembled and reworked with solder interconnects consisting of mixed alloys, lead component finish/lead-free solder and lead-free component finish/SnPb solder.

  11. An FEC Adaptive Multicast MAC Protocol for Providing Reliability in WLANs

    NASA Astrophysics Data System (ADS)

    Basalamah, Anas; Sato, Takuro

    For wireless multicast applications like multimedia conferencing, voice over IP and video/audio streaming, a reliable transmission of packets within short delivery delay is needed. Moreover, reliability is crucial to the performance of error intolerant applications like file transfer, distributed computing, chat and whiteboard sharing. Forward Error Correction (FEC) is frequently used in wireless multicast to enhance Packet Error Rate (PER) performance, but cannot assure full reliability unless coupled with Automatic Repeat Request forming what is knows as Hybrid-ARQ. While reliable FEC can be deployed at different levels of the protocol stack, it cannot be deployed on the MAC layer of the unreliable IEEE802.11 WLAN due to its inability to exchange ACKs with multiple recipients. In this paper, we propose a Multicast MAC protocol that enhances WLAN reliability by using Adaptive FEC and study it's performance through mathematical analysis and simulation. Our results show that our protocol can deliver high reliability and throughput performance.

  12. NASA Advanced Exploration Systems: Advancements in Life Support Systems

    NASA Technical Reports Server (NTRS)

    Shull, Sarah A.; Schneider, Walter F.

    2016-01-01

    The NASA Advanced Exploration Systems (AES) Life Support Systems (LSS) project strives to develop reliable, energy-efficient, and low-mass spacecraft systems to provide environmental control and life support systems (ECLSS) critical to enabling long duration human missions beyond low Earth orbit (LEO). Highly reliable, closed-loop life support systems are among the capabilities required for the longer duration human space exploration missions assessed by NASA’s Habitability Architecture Team.

  13. Vulcain engine tests prove reliability

    NASA Astrophysics Data System (ADS)

    Covault, Craig

    1994-04-01

    The development of the oxygen/hydrogen Vulcain first-stage engine for the Ariane 5 involves more than 30 European companies and $1.19-billion. These companies are using existing technology to produce a low-cost system with high thrust and reliability. This article describes ground test of this engine, and provides a comparison of the Vulcain's capabilities with the capabilities of other systems. A list of key Vulcain team members is also given.

  14. Requirements for conformal coating and staking of printed wiring boards and electronic assemblies

    NASA Technical Reports Server (NTRS)

    1985-01-01

    In order to maintain the high standards of the NASA conformal coating and staking program, this publication: prescribes NASA's requirements for assuring reliable conformal coating and staking for printed wiring boards and electronic assemblies; describes and incorporates basic considerations necessary to assure reliable conformal coating and staking; establishes the supplier's responsibility to train and certify personnel; provides for supplier documentation of the fabrication and inspection procedures to be used for NASA work, including supplier innovations and changes in technology; and provides visual workmanship standards to aid those responsible for determining quality conformance to the established requirements.

  15. Next-generation sequencing coupled with a cell-free display technology for high-throughput production of reliable interactome data

    PubMed Central

    Fujimori, Shigeo; Hirai, Naoya; Ohashi, Hiroyuki; Masuoka, Kazuyo; Nishikimi, Akihiko; Fukui, Yoshinori; Washio, Takanori; Oshikubo, Tomohiro; Yamashita, Tatsuhiro; Miyamoto-Sato, Etsuko

    2012-01-01

    Next-generation sequencing (NGS) has been applied to various kinds of omics studies, resulting in many biological and medical discoveries. However, high-throughput protein-protein interactome datasets derived from detection by sequencing are scarce, because protein-protein interaction analysis requires many cell manipulations to examine the interactions. The low reliability of the high-throughput data is also a problem. Here, we describe a cell-free display technology combined with NGS that can improve both the coverage and reliability of interactome datasets. The completely cell-free method gives a high-throughput and a large detection space, testing the interactions without using clones. The quantitative information provided by NGS reduces the number of false positives. The method is suitable for the in vitro detection of proteins that interact not only with the bait protein, but also with DNA, RNA and chemical compounds. Thus, it could become a universal approach for exploring the large space of protein sequences and interactome networks. PMID:23056904

  16. Effect of Pd Surface Roughness on the Bonding Process and High Temperature Reliability of Au Ball Bonds

    NASA Astrophysics Data System (ADS)

    Huang, Y.; Kim, H. J.; McCracken, M.; Viswanathan, G.; Pon, F.; Mayer, M.; Zhou, Y. N.

    2011-06-01

    A 0.3- μm-thick electrolytic Pd layer was plated on 1 μm of electroless Ni on 1 mm-thick polished and roughened Cu substrates with roughness values ( R a) of 0.08 μm and 0.5 μm, respectively. The rough substrates were produced with sand-blasting. Au wire bonding on the Ni/Pd surface was optimized, and the electrical reliability was investigated under a high temperature storage test (HTST) during 800 h at 250°C by measuring the ball bond contact resistance, R c. The average value of R c of optimized ball bonds on the rough substrate was 1.96 mΩ which was about 40.0% higher than that on the smooth substrate. The initial bondability increased for the rougher surface, so that only half of the original ultrasonic level was required, but the reliability was not affected by surface roughness. For both substrate types, HTST caused bond healing, reducing the average R c by about 21% and 27%, respectively. Au diffusion into the Pd layer was observed in scanning transmission electron microscopy/ energy dispersive spectroscopy (STEM-EDS) line-scan analysis after HTST. It is considered that diffusion of Au or interdiffusion between Au and Pd can provide chemically strong bonding during HTST. This is supported by the R c decrease measured as the aging time increased. Cu migration was indicated in the STEM-EDS analysis, but its effect on reliability can be ignored. Au and Pd tend to form a complete solid solution at the interface and can provide reliable interconnection for high temperature (250°C) applications.

  17. Reliability of EEG Interactions Differs between Measures and Is Specific for Neurological Diseases

    PubMed Central

    Höller, Yvonne; Butz, Kevin; Thomschewski, Aljoscha; Schmid, Elisabeth; Uhl, Andreas; Bathke, Arne C.; Zimmermann, Georg; Tomasi, Santino O.; Nardone, Raffaele; Staffen, Wolfgang; Höller, Peter; Leitinger, Markus; Höfler, Julia; Kalss, Gudrun; Taylor, Alexandra C.; Kuchukhidze, Giorgi; Trinka, Eugen

    2017-01-01

    Alterations of interaction (connectivity) of the EEG reflect pathological processes in patients with neurologic disorders. Nevertheless, it is questionable whether these patterns are reliable over time in different measures of interaction and whether this reliability of the measures is the same across different patient populations. In order to address this topic we examined 22 patients with mild cognitive impairment, five patients with subjective cognitive complaints, six patients with right-lateralized temporal lobe epilepsy, seven patients with left lateralized temporal lobe epilepsy, and 20 healthy controls. We calculated 14 measures of interaction from two EEG-recordings separated by 2 weeks. In order to characterize test-retest reliability, we correlated these measures for each group and compared the correlations between measures and between groups. We found that both measures of interaction as well as groups differed from each other in terms of reliability. The strongest correlation coefficients were found for spectrum, coherence, and full frequency directed transfer function (average rho > 0.9). In the delta (2–4 Hz) range, reliability was lower for mild cognitive impairment compared to healthy controls and left lateralized temporal lobe epilepsy. In the beta (13–30 Hz), gamma (31–80 Hz), and high gamma (81–125 Hz) frequency ranges we found decreased reliability in subjective cognitive complaints compared to mild cognitive impairment. In the gamma and high gamma range we found increased reliability in left lateralized temporal lobe epilepsy patients compared to healthy controls. Our results emphasize the importance of documenting reliability of measures of interaction, which may vary considerably between measures, but also between patient populations. We suggest that studies claiming clinical usefulness of measures of interaction should provide information on the reliability of the results. In addition, differences between patient groups in reliability of interactions in the EEG indicate the potential of reliability to serve as a new biomarker for pathological memory decline as well as for epilepsy. While the brain concert of information flow is generally variable, high reliability, and thus, low variability may reflect abnormal firing patterns. PMID:28725190

  18. Children and their parents assessing the doctor-patient interaction: a rating system for doctors' communication skills.

    PubMed

    Crossley, Jim; Eiser, Christine; Davies, Helena A

    2005-08-01

    Only a patient and his or her family can judge many of the most important aspects of the doctor-patient interaction. This study evaluates the feasibility and reliability of children and their families assessing the quality of paediatricians' interactions using a rating instrument developed specifically for this purpose. A reliability analysis using generalisability theory on the ratings from 352 doctor-patient interactions across different speciality clinics. Ratings were normally distributed. They were highest for 'overall' performance, and lowest for giving time to discuss the families' agenda. An appropriate sample of adults' ratings provided a reliable score (G = 0.7 with 15 raters), but children's ratings were too idiosyncratic to be reproducible (G = 0.36 with 15 raters). CONCLUSIONS AND FURTHER WORK: Accompanying adults can provide reliable ratings of doctors' interactions with children. Because an adult is usually present at the consultation their ratings provide a highly feasible and authentic approach. Sampling doctors' interactions from different clinics and with patients of both genders provides a universal picture of performance. The method is ideal to measure performance for in-training assessment or revalidation. Further work is in progress to evaluate the educational impact of feeding ratings back to the doctors being assessed, and their use in a range of clinical contexts.

  19. Expanding the Scope of High-Performance Computing Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uram, Thomas D.; Papka, Michael E.

    The high-performance computing centers of the future will expand their roles as service providers, and as the machines scale up, so should the sizes of the communities they serve. National facilities must cultivate their users as much as they focus on operating machines reliably. The authors present five interrelated topic areas that are essential to expanding the value provided to those performing computational science.

  20. Understanding the Reliability of Solder Joints Used in Advanced Structural and Electronics Applications: Part 2 - Reliability Performance.

    DOE PAGES

    Vianco, Paul T.

    2017-03-01

    Whether structural or electronic, all solder joints must provide the necessary level of reliability for the application. The Part 1 report examined the effects of filler metal properties and the soldering process on joint reliability. Filler metal solderability and mechanical properties, as well as the extents of base material dissolution and interface reaction that occur during the soldering process, were shown to affect reliability performance. The continuation of this discussion is presented in this Part 2 report, which highlights those factors that directly affect solder joint reliability. There is the growth of an intermetallic compound (IMC) reaction layer at themore » solder/base material interface by means of solid-state diffusion processes. In terms of mechanical response by the solder joint, fatigue remains as the foremost concern for long-term performance. Thermal mechanical fatigue (TMF), a form of low-cycle fatigue (LCF), occurs when temperature cycling is combined with mismatched values of the coefficient of thermal expansion (CTE) between materials comprising the solder joint “system.” Vibration environments give rise to high-cycle fatigue (HCF) degradation. Although accelerated aging studies provide valuable empirical data, too many variants of filler metals, base materials, joint geometries, and service environments are forcing design engineers to embrace computational modeling to predict the long-term reliability of solder joints.« less

  1. High reliability - low noise radionuclide signature identification algorithms for border security applications

    NASA Astrophysics Data System (ADS)

    Lee, Sangkyu

    Illicit trafficking and smuggling of radioactive materials and special nuclear materials (SNM) are considered as one of the most important recent global nuclear threats. Monitoring the transport and safety of radioisotopes and SNM are challenging due to their weak signals and easy shielding. Great efforts worldwide are focused at developing and improving the detection technologies and algorithms, for accurate and reliable detection of radioisotopes of interest in thus better securing the borders against nuclear threats. In general, radiation portal monitors enable detection of gamma and neutron emitting radioisotopes. Passive or active interrogation techniques, present and/or under the development, are all aimed at increasing accuracy, reliability, and in shortening the time of interrogation as well as the cost of the equipment. Equally important efforts are aimed at advancing algorithms to process the imaging data in an efficient manner providing reliable "readings" of the interiors of the examined volumes of various sizes, ranging from cargos to suitcases. The main objective of this thesis is to develop two synergistic algorithms with the goal to provide highly reliable - low noise identification of radioisotope signatures. These algorithms combine analysis of passive radioactive detection technique with active interrogation imaging techniques such as gamma radiography or muon tomography. One algorithm consists of gamma spectroscopy and cosmic muon tomography, and the other algorithm is based on gamma spectroscopy and gamma radiography. The purpose of fusing two detection methodologies per algorithm is to find both heavy-Z radioisotopes and shielding materials, since radionuclides can be identified with gamma spectroscopy, and shielding materials can be detected using muon tomography or gamma radiography. These combined algorithms are created and analyzed based on numerically generated images of various cargo sizes and materials. In summary, the three detection methodologies are fused into two algorithms with mathematical functions providing: reliable identification of radioisotopes in gamma spectroscopy; noise reduction and precision enhancement in muon tomography; and the atomic number and density estimation in gamma radiography. It is expected that these new algorithms maybe implemented at portal scanning systems with the goal to enhance the accuracy and reliability in detecting nuclear materials inside the cargo containers.

  2. Test-retest reliability of resting-state magnetoencephalography power in sensor and source space.

    PubMed

    Martín-Buro, María Carmen; Garcés, Pilar; Maestú, Fernando

    2016-01-01

    Several studies have reported changes in spontaneous brain rhythms that could be used as clinical biomarkers or in the evaluation of neuropsychological and drug treatments in longitudinal studies using magnetoencephalography (MEG). There is an increasing necessity to use these measures in early diagnosis and pathology progression; however, there is a lack of studies addressing how reliable they are. Here, we provide the first test-retest reliability estimate of MEG power in resting-state at sensor and source space. In this study, we recorded 3 sessions of resting-state MEG activity from 24 healthy subjects with an interval of a week between each session. Power values were estimated at sensor and source space with beamforming for classical frequency bands: delta (2-4 Hz), theta (4-8 Hz), alpha (8-13 Hz), low beta (13-20 Hz), high beta (20-30 Hz), and gamma (30-45 Hz). Then, test-retest reliability was evaluated using the intraclass correlation coefficient (ICC). We also evaluated the relation between source power and the within-subject variability. In general, ICC of theta, alpha, and low beta power was fairly high (ICC > 0.6) while in delta and gamma power was lower. In source space, fronto-posterior alpha, frontal beta, and medial temporal theta showed the most reliable profiles. Signal-to-noise ratio could be partially responsible for reliability as low signal intensity resulted in high within-subject variability, but also the inherent nature of some brain rhythms in resting-state might be driving these reliability patterns. In conclusion, our results described the reliability of MEG power estimates in each frequency band, which could be considered in disease characterization or clinical trials. © 2015 Wiley Periodicals, Inc.

  3. Puncture Self-Healing Polymers for Aerospace Applications

    NASA Technical Reports Server (NTRS)

    Gordon, Keith L.; Penner, Ronald K.; Bogert, Phil B.; Yost, W. T.; Siochi, Emilie J.

    2011-01-01

    Space exploration launch costs on the order of $10K per pound provide ample incentive to seek innovative, cost-effective ways to reduce structural mass without sacrificing safety and reliability. Damage-tolerant structural systems can provide a route to avoiding weight penalty while enhancing vehicle safety and reliability. Self-healing polymers capable of spontaneous puncture repair show great promise to mitigate potentially catastrophic damage from events such as micrometeoroid penetration. Effective self-repair requires these materials to heal instantaneously following projectile penetration while retaining structural integrity. Poly(ethylene-co-methacrylic acid) (EMMA), also known as Surlyn is an ionomer-based copolymer that undergoes puncture reversal (self-healing) following high impact puncture at high velocities. However EMMA is not a structural engineering polymer, and will not meet the demands of aerospace applications requiring self-healing engineering materials. Current efforts to identify candidate self-healing polymer materials for structural engineering systems are reported. Rheology, high speed thermography, and high speed video for self-healing semi-crystalline and amorphous polymers will be reported.

  4. Chart Notes from a Sports Nutritionist.

    ERIC Educational Resources Information Center

    Clark, Nancy

    1986-01-01

    A sports nutritionist/registered dietician on the sports medicine team can provide clients with reliable nutrition information and respond to their interest in healthful, high-energy eating. Three case reports illustrate the usefulness of a nutritionist to practitioners of sports medicine. A chart of healthful foods is provided. (MT)

  5. beta-Aminoalcohols as Potential Reactivators of Aged Sarin-/Soman-Inhibited Acetylcholinesterase

    DTIC Science & Technology

    2017-02-08

    This approach includes high - quality quantum mechanical/molecular mechanical calcula- tions, providing reliable reactivation steps and energetics...I. V. Khavrutskii Department of Defense Biotechnology High Performance Computing Software Applications Institute Telemedicine and Advanced...b] Dr. A. Wallqvist Department of Defense Biotechnology High Performance Computing Software Applications Institute Telemedicine and Advanced

  6. Neck motion kinematics: an inter-tester reliability study using an interactive neck VR assessment in asymptomatic individuals.

    PubMed

    Sarig Bahat, Hilla; Sprecher, Elliot; Sela, Itamar; Treleaven, Julia

    2016-07-01

    The use of virtual reality (VR) for assessment and intervention of neck pain has previously been used and shown reliable for cervical range of motion measures. Neck VR enables analysis of task-oriented neck movement by stimulating responsive movements to external stimuli. Therefore, the purpose of this study was to establish inter-tester reliability of neck kinematic measures so that it can be used as a reliable assessment and treatment tool between clinicians. This reliability study included 46 asymptomatic participants, who were assessed using the neck VR system which displayed an interactive VR scenario via a head-mounted device, controlled by neck movements. The objective of the interactive assessment was to hit 16 targets, randomly appearing in four directions, as fast as possible. Each participant was tested twice by two different testers. Good reliability was found of neck motion kinematic measures in flexion, extension, and rotation (0.64-0.93 inter-class correlation). High reliability was shown for peak velocity globally (0.93), in left rotation (0.9), right rotation and extension (0.88), and flexion (0.86). Mean velocity had a good global reliability (0.84), except for left rotation directed movement with moderate reliability (0.68). Minimal detectable change for peak velocity ranged from 41 to 53 °/s, while mean velocity ranged from 20 to 25 °/s. The results suggest high reliability for peak and mean velocity as measured by the interactive Neck VR assessment of neck motion kinematics. VR appears to provide a reliable and more ecologically valid method of cervical motion evaluation than previous conventional methodologies.

  7. [Reliability of the Japanese version of the Scale for the Assessment and Rating of Ataxia (SARA)].

    PubMed

    Sato, Kazunori; Yabe, Ichiro; Soma, Hiroyuki; Yasui, Kenichi; Ito, Mizuki; Shimohata, Takayoshi; Onodera, Osamu; Nakashima, Kenji; Sobue, Gen; Nishizawa, Masatoyo; Sasaki, Hidenao

    2009-05-01

    The International Cooperative Ataxia Rating Scale (ICARS) is widely used as a scale for the assessment of the severity of cerebellar ataxia. However, this scale comprises several items; thus, making the application of this scale is not sufficiently practical to perform daily assessment of ataxic patients. A new rating scale--Scale for the Assessment and Rating of Ataxia (SARA)--was shown to provide highly reliable assessments; further, the scores on SARA correlated with the ICARS score and the Barthel index. After obtaining the permission, original SARA was translated into Japanese. To examine the reliability and internal consistency of the Japanese version of the SARA for the assessment of cerebellar ataxia in 66 patients with spinocerebellar degeneration. Intraclass coefficients (ICC) were observed to be greater than 0.8 except in the case of the inter-rater "finger chase" and "fast alternating hand movement" tests. The Japanese version of SARA is highly reliable and very useful for the assessment of cerebellar ataxia on a daily basis.

  8. FERMI: a digital Front End and Readout MIcrosystem for high resolution calorimetry

    NASA Astrophysics Data System (ADS)

    Alexanian, H.; Appelquist, G.; Bailly, P.; Benetta, R.; Berglund, S.; Bezamat, J.; Blouzon, F.; Bohm, C.; Breveglieri, L.; Brigati, S.; Cattaneo, P. W.; Dadda, L.; David, J.; Engström, M.; Genat, J. F.; Givoletti, M.; Goggi, V. G.; Gong, S.; Grieco, G. M.; Hansen, M.; Hentzell, H.; Holmberg, T.; Höglund, I.; Inkinen, S. J.; Kerek, A.; Landi, C.; Ledortz, O.; Lippi, M.; Lofstedt, B.; Lund-Jensen, B.; Maloberti, F.; Mutz, S.; Nayman, P.; Piuri, V.; Polesello, G.; Sami, M.; Savoy-Navarro, A.; Schwemling, P.; Stefanelli, R.; Sundblad, R.; Svensson, C.; Torelli, G.; Vanuxem, J. P.; Yamdagni, N.; Yuan, J.; Ödmark, A.; Fermi Collaboration

    1995-02-01

    We present a digital solution for the front-end electronics of high resolution calorimeters at future colliders. It is based on analogue signal compression, high speed {A}/{D} converters, a fully programmable pipeline and a digital signal processing (DSP) chain with local intelligence and system supervision. This digital solution is aimed at providing maximal front-end processing power by performing waveform analysis using DSP methods. For the system integration of the multichannel device a multi-chip, silicon-on-silicon multi-chip module (MCM) has been adopted. This solution allows a high level of integration of complex analogue and digital functions, with excellent flexibility in mixing technologies for the different functional blocks. This type of multichip integration provides a high degree of reliability and programmability at both the function and the system level, with the additional possibility of customising the microsystem to detector-specific requirements. For enhanced reliability in high radiation environments, fault tolerance strategies, i.e. redundancy, reconfigurability, majority voting and coding for error detection and correction, are integrated into the design.

  9. Improvement of automatic control system for high-speed current collectors

    NASA Astrophysics Data System (ADS)

    Sidorov, O. A.; Goryunov, V. N.; Golubkov, A. S.

    2018-01-01

    The article considers the ways of regulation of pantographs to provide quality and reliability of current collection at high speeds. To assess impact of regulation was proposed integral criterion of the quality of current collection, taking into account efficiency and reliability of operation of the pantograph. The study was carried out using mathematical model of interaction of pantograph and catenary system, allowing to assess contact force and intensity of arcing at the contact zone at different movement speeds. The simulation results allowed us to estimate the efficiency of different methods of regulation of pantographs and determine the best option.

  10. Digital assessment of the fetal alcohol syndrome facial phenotype: reliability and agreement study.

    PubMed

    Tsang, Tracey W; Laing-Aiken, Zoe; Latimer, Jane; Fitzpatrick, James; Oscar, June; Carter, Maureen; Elliott, Elizabeth J

    2017-01-01

    To examine the three facial features of fetal alcohol syndrome (FAS) in a cohort of Australian Aboriginal children from two-dimensional digital facial photographs to: (1) assess intrarater and inter-rater reliability; (2) identify the racial norms with the best fit for this population; and (3) assess agreement with clinician direct measures. Photographs and clinical data for 106 Aboriginal children (aged 7.4-9.6 years) were sourced from the Lililwan Project . Fifty-eight per cent had a confirmed prenatal alcohol exposure and 13 (12%) met the Canadian 2005 criteria for FAS/partial FAS. Photographs were analysed using the FAS Facial Photographic Analysis Software to generate the mean PFL three-point ABC-Score, five-point lip and philtrum ranks and four-point face rank in accordance with the 4-Digit Diagnostic Code. Intrarater and inter-rater reliability of digital ratings was examined in two assessors. Caucasian or African American racial norms for PFL and lip thickness were assessed for best fit; and agreement between digital and direct measurement methods was assessed. Reliability of digital measures was substantial within (kappa: 0.70-1.00) and between assessors (kappa: 0.64-0.89). Clinician and digital ratings showed moderate agreement (kappa: 0.47-0.58). Caucasian PFL norms and the African American Lip-Philtrum Guide 2 provided the best fit for this cohort. In an Aboriginal cohort with a high rate of FAS, assessment of facial dysmorphology using digital methods showed substantial inter- and intrarater reliability. Digital measurement of features has high reliability and until data are available from a larger population of Aboriginal children, the African American Lip-Philtrum Guide 2 and Caucasian (Strömland) PFL norms provide the best fit for Australian Aboriginal children.

  11. Reliability analysis of the epidural spinal cord compression scale.

    PubMed

    Bilsky, Mark H; Laufer, Ilya; Fourney, Daryl R; Groff, Michael; Schmidt, Meic H; Varga, Peter Paul; Vrionis, Frank D; Yamada, Yoshiya; Gerszten, Peter C; Kuklo, Timothy R

    2010-09-01

    The evolution of imaging techniques, along with highly effective radiation options has changed the way metastatic epidural tumors are treated. While high-grade epidural spinal cord compression (ESCC) frequently serves as an indication for surgical decompression, no consensus exists in the literature about the precise definition of this term. The advancement of the treatment paradigms in patients with metastatic tumors for the spine requires a clear grading scheme of ESCC. The degree of ESCC often serves as a major determinant in the decision to operate or irradiate. The purpose of this study was to determine the reliability and validity of a 6-point, MR imaging-based grading system for ESCC. To determine the reliability of the grading scale, a survey was distributed to 7 spine surgeons who participate in the Spine Oncology Study Group. The MR images of 25 cervical or thoracic spinal tumors were distributed consisting of 1 sagittal image and 3 axial images at the identical level including T1-weighted, T2-weighted, and Gd-enhanced T1-weighted images. The survey was administered 3 times at 2-week intervals. The inter- and intrarater reliability was assessed. The inter- and intrarater reliability ranged from good to excellent when surgeons were asked to rate the degree of spinal cord compression using T2-weighted axial images. The T2-weighted images were superior indicators of ESCC compared with T1-weighted images with and without Gd. The ESCC scale provides a valid and reliable instrument that may be used to describe the degree of ESCC based on T2-weighted MR images. This scale accounts for recent advances in the treatment of spinal metastases and may be used to provide an ESCC classification scheme for multicenter clinical trial and outcome studies.

  12. Displaying contextual information reduces the costs of imperfect decision automation in rapid retasking of ISR assets.

    PubMed

    Rovira, Ericka; Cross, Austin; Leitch, Evan; Bonaceto, Craig

    2014-09-01

    The impact of a decision support tool designed to embed contextual mission factors was investigated. Contextual information may enable operators to infer the appropriateness of data underlying the automation's algorithm. Research has shown the costs of imperfect automation are more detrimental than perfectly reliable automation when operators are provided with decision support tools. Operators may trust and rely on the automation more appropriately if they understand the automation's algorithm. The need to develop decision support tools that are understandable to the operator provides the rationale for the current experiment. A total of 17 participants performed a simulated rapid retasking of intelligence, surveillance, and reconnaissance (ISR) assets task with manual, decision automation, or contextual decision automation differing in two levels of task demand: low or high. Automation reliability was set at 80%, resulting in participants experiencing a mixture of reliable and automation failure trials. Dependent variables included ISR coverage and response time of replanning routes. Reliable automation significantly improved ISR coverage when compared with manual performance. Although performance suffered under imperfect automation, contextual decision automation helped to reduce some of the decrements in performance. Contextual information helps overcome the costs of imperfect decision automation. Designers may mitigate some of the performance decrements experienced with imperfect automation by providing operators with interfaces that display contextual information, that is, the state of factors that affect the reliability of the automation's recommendation.

  13. Design, Implementation, and Verification of the Reliable Multicast Protocol. Thesis

    NASA Technical Reports Server (NTRS)

    Montgomery, Todd L.

    1995-01-01

    This document describes the Reliable Multicast Protocol (RMP) design, first implementation, and formal verification. RMP provides a totally ordered, reliable, atomic multicast service on top of an unreliable multicast datagram service. RMP is fully and symmetrically distributed so that no site bears an undue portion of the communications load. RMP provides a wide range of guarantees, from unreliable delivery to totally ordered delivery, to K-resilient, majority resilient, and totally resilient atomic delivery. These guarantees are selectable on a per message basis. RMP provides many communication options, including virtual synchrony, a publisher/subscriber model of message delivery, a client/server model of delivery, mutually exclusive handlers for messages, and mutually exclusive locks. It has been commonly believed that total ordering of messages can only be achieved at great performance expense. RMP discounts this. The first implementation of RMP has been shown to provide high throughput performance on Local Area Networks (LAN). For two or more destinations a single LAN, RMP provides higher throughput than any other protocol that does not use multicast or broadcast technology. The design, implementation, and verification activities of RMP have occurred concurrently. This has allowed the verification to maintain a high fidelity between design model, implementation model, and the verification model. The restrictions of implementation have influenced the design earlier than in normal sequential approaches. The protocol as a whole has matured smoother by the inclusion of several different perspectives into the product development.

  14. The new GRID Hamilton Rating Scale for Depression demonstrates excellent inter-rater reliability for inexperienced and experienced raters before and after training.

    PubMed

    Tabuse, Hideaki; Kalali, Amir; Azuma, Hideki; Ozaki, Norio; Iwata, Nakao; Naitoh, Hiroshi; Higuchi, Teruhiko; Kanba, Shigenobu; Shioe, Kunihiko; Akechi, Tatsuo; Furukawa, Toshi A

    2007-09-30

    The Hamilton Rating Scale for Depression (HAMD) is the de facto international gold standard for the assessment of depression. There are some criticisms, however, especially with regard to its inter-rater reliability, due to the lack of standardized questions or explicit scoring procedures. The GRID-HAMD was developed to provide standardized explicit scoring conventions and a structured interview guide for administration and scoring of the HAMD. We developed the Japanese version of the GRID-HAMD and examined its inter-rater reliability among experienced and inexperienced clinicians (n=70), how rater characteristics may affect it, and how training can improve it in the course of a model training program using videotaped interviews. The results showed that the inter-rater reliability of the GRID-HAMD total score was excellent to almost perfect and those of most individual items were also satisfactory to excellent, both with experienced and inexperienced raters, and both before and after the training. With its standardized definitions, questions and detailed scoring conventions, the GRID-HAMD appears to be the best achievable set of interview guides for the HAMD and can provide a solid tool for highly reliable assessment of depression severity.

  15. Affordable Launch Services using the Sport Orbit Transfer System

    NASA Astrophysics Data System (ADS)

    Goldstein, D. J.

    2002-01-01

    Despite many advances in small satellite technology, a low-cost, reliable method is needed to place spacecraft in their de- sired orbits. AeroAstro has developed the Small Payload ORbit Transfer (SPORTTM) system to provide a flexible low-cost orbit transfer capability, enabling small payloads to use low-cost secondary launch opportunities and still reach their desired final orbits. This capability allows small payloads to effectively use a wider variety of launch opportunities, including nu- merous under-utilized GTO slots. Its use, in conjunction with growing opportunities for secondary launches, enable in- creased access to space using proven technologies and highly reliable launch vehicles such as the Ariane family and the Starsem launcher. SPORT uses a suite of innovative technologies that are packaged in a simple, reliable, modular system. The command, control and data handling of SPORT is provided by the AeroAstro BitsyTM core electronics module. The Bitsy module also provides power regulation for the batteries and optional solar arrays. The primary orbital maneuvering capability is provided by a nitrous oxide monopropellant propulsion system. This system exploits the unique features of nitrous oxide, which in- clude self-pressurization, good performance, and safe handling, to provide a light-weight, low-cost and reliable propulsion capability. When transferring from a higher energy orbit to a lower energy orbit (i.e. GTO to LEO), SPORT uses aerobraking technol- ogy. After using the propulsion system to lower the orbit perigee, the aerobrake gradually slows SPORT via atmospheric drag. After the orbit apogee is reduced to the target level, an apogee burn raises the perigee and ends the aerobraking. At the conclusion of the orbit transfer maneuver, either the aerobrake or SPORT can be shed, as desired by the payload. SPORT uses a simple design for high reliability and a modular architecture for maximum mission flexibility. This paper will discuss the launch system and its application to small satellite launch without increasing risk. It will also discuss relevant issues such as aerobraking operations and radiation issues, as well as existing partnerships and patents for the system.

  16. Intraday and Interday Reliability of Ultra-Short-Term Heart Rate Variability in Rugby Union Players.

    PubMed

    Nakamura, Fábio Y; Pereira, Lucas A; Esco, Michael R; Flatt, Andrew A; Moraes, José E; Cal Abad, Cesar C; Loturco, Irineu

    2017-02-01

    Nakamura, FY, Pereira, LA, Esco, MR, Flatt, AA, Moraes, JE, Cal Abad, CC, and Loturco, I. Intraday and interday reliability of ultra-short-term heart rate variability in rugby union players. J Strength Cond Res 31(2): 548-551, 2017-The aim of this study was to examine the intraday and interday reliability of ultra-short-term vagal-related heart rate variability (HRV) in elite rugby union players. Forty players from the Brazilian National Rugby Team volunteered to participate in this study. The natural log of the root mean square of successive RR interval differences (lnRMSSD) assessments were performed on 4 different days. The HRV was assessed twice (intraday reliability) on the first day and once per day on the following 3 days (interday reliability). The RR interval recordings were obtained from 2-minute recordings using a portable heart rate monitor. The relative reliability of intraday and interday lnRMSSD measures was analyzed using the intraclass correlation coefficient (ICC). The typical error of measurement (absolute reliability) of intraday and interday lnRMSSD assessments was analyzed using the coefficient of variation (CV). Both intraday (ICC = 0.96; CV = 3.99%) and interday (ICC = 0.90; CV = 7.65%) measures were highly reliable. The ultra-short-term lnRMSSD is a consistent measure for evaluating elite rugby union players, in both intraday and interday settings. This study provides further validity to using this shortened method in practical field conditions with highly trained team sports athletes.

  17. Distributed collaborative response surface method for mechanical dynamic assembly reliability design

    NASA Astrophysics Data System (ADS)

    Bai, Guangchen; Fei, Chengwei

    2013-11-01

    Because of the randomness of many impact factors influencing the dynamic assembly relationship of complex machinery, the reliability analysis of dynamic assembly relationship needs to be accomplished considering the randomness from a probabilistic perspective. To improve the accuracy and efficiency of dynamic assembly relationship reliability analysis, the mechanical dynamic assembly reliability(MDAR) theory and a distributed collaborative response surface method(DCRSM) are proposed. The mathematic model of DCRSM is established based on the quadratic response surface function, and verified by the assembly relationship reliability analysis of aeroengine high pressure turbine(HPT) blade-tip radial running clearance(BTRRC). Through the comparison of the DCRSM, traditional response surface method(RSM) and Monte Carlo Method(MCM), the results show that the DCRSM is not able to accomplish the computational task which is impossible for the other methods when the number of simulation is more than 100 000 times, but also the computational precision for the DCRSM is basically consistent with the MCM and improved by 0.40˜4.63% to the RSM, furthermore, the computational efficiency of DCRSM is up to about 188 times of the MCM and 55 times of the RSM under 10000 times simulations. The DCRSM is demonstrated to be a feasible and effective approach for markedly improving the computational efficiency and accuracy of MDAR analysis. Thus, the proposed research provides the promising theory and method for the MDAR design and optimization, and opens a novel research direction of probabilistic analysis for developing the high-performance and high-reliability of aeroengine.

  18. High-Reliability Pump Module for Non-Planar Ring Oscillator Laser

    NASA Technical Reports Server (NTRS)

    Liu, Duncan T.; Qiu, Yueming; Wilson, Daniel W.; Dubovitsky, Serge; Forouhar, Siamak

    2007-01-01

    We propose and have demonstrated a prototype high-reliability pump module for pumping a Non-Planar Ring Oscillator (NPRO) laser suitable for space missions. The pump module consists of multiple fiber-coupled single-mode laser diodes and a fiber array micro-lens array based fiber combiner. The reported Single-Mode laser diode combiner laser pump module (LPM) provides a higher normalized brightness at the combined beam than multimode laser diode based LPMs. A higher brightness from the pump source is essential for efficient NPRO laser pumping and leads to higher reliability because higher efficiency requires a lower operating power for the laser diodes, which in turn increases the reliability and lifetime of the laser diodes. Single-mode laser diodes with Fiber Bragg Grating (FBG) stabilized wavelength permit the pump module to be operated without a thermal electric cooler (TEC) and this further improves the overall reliability of the pump module. The single-mode laser diode LPM is scalable in terms of the number of pump diodes and is capable of combining hundreds of fiber-coupled laser diodes. In the proof-of-concept demonstration, an e-beam written diffractive micro lens array, a custom fiber array, commercial 808nm single mode laser diodes, and a custom NPRO laser head are used. The reliability of the proposed LPM is discussed.

  19. Intra and interrater reliability of spinal sagittal curves and mobility using pocket goniometer IncliMed® in healthy subjects.

    PubMed

    Alderighi, Marzia; Ferrari, Raffaello; Maghini, Irene; Del Felice, Alessandra; Masiero, Stefano

    2016-11-21

    Radiographic examination is the gold standard to evaluate spine curves, but ionising radiations limit routine use. Non-invasive methods, such as skin-surface goniometer (IncliMed®) should be used instead. To evaluate intra- and interrater reliability to assess sagittal curves and mobility of the spine with IncliMed®. a reliability study on agonistic football players. Thoracic kyphosis, lumbar lordosis and mobility of the spine were assessed by IncliMed®. Measurements were repeated twice by each examiner during the same session with between-rater blinding. Intrarater and interrater reliability were measured by Intraclass Correlation Coefficient (ICC), 95% Confidence Interval (CI 95%) and Standard Error of Measurement (SEM). Thirty-four healthy female football players (19.17 ± 4.52 years) were enrolled. Statistical results showed high intrarater (0.805-0.923) and interrater (0.701-0.886) reliability (ICC > 0.8). The obtained intra- and interrater SEM were low, with overall absolute intrarater values between 1.39° and 2.76° and overall interrater values between 1.71° and 4.25°. IncliMed® provides high intra- and interrater reliability in healthy subjects, with limited Standard Error of Measurement. These results encourage its use in clinical practice and scientific research.

  20. Prognostics-based qualification of high-power white LEDs using Lévy process approach

    NASA Astrophysics Data System (ADS)

    Yung, Kam-Chuen; Sun, Bo; Jiang, Xiaopeng

    2017-01-01

    Due to their versatility in a variety of applications and the growing market demand, high-power white light-emitting diodes (LEDs) have attracted considerable attention. Reliability qualification testing is an essential part of the product development process to ensure the reliability of a new LED product before its release. However, the widely used IES-TM-21 method does not provide comprehensive reliability information. For more accurate and effective qualification, this paper presents a novel method based on prognostics techniques. Prognostics is an engineering technology predicting the future reliability or determining the remaining useful lifetime (RUL) of a product by assessing the extent of deviation or degradation from its expected normal operating conditions. A Lévy subordinator of a mixed Gamma and compound Poisson process is used to describe the actual degradation process of LEDs characterized by random sporadic small jumps of degradation degree, and the reliability function is derived for qualification with different distribution forms of jump sizes. The IES LM-80 test results reported by different LED vendors are used to develop and validate the qualification methodology. This study will be helpful for LED manufacturers to reduce the total test time and cost required to qualify the reliability of an LED product.

  1. Environmental Response Laboratory Network (ERLN) Overview

    EPA Pesticide Factsheets

    The Environmental Response Laboratory Network provides Federal, State, and local decision-makers with reliable, high quality analytical data used to identify chemical, biological, and radiological contaminants collected in support of response and cleanup.

  2. Reliability and Validity of the Arthroscopic International Cartilage Repair Society Classification System: Correlation With Histological Assessment of Depth.

    PubMed

    Dwyer, Tim; Martin, C Ryan; Kendra, Rita; Sermer, Corey; Chahal, Jaskarndip; Ogilvie-Harris, Darrell; Whelan, Daniel; Murnaghan, Lucas; Nauth, Aaron; Theodoropoulos, John

    2017-06-01

    To determine the interobserver reliability of the International Cartilage Repair Society (ICRS) grading system of chondral lesions in cadavers, to determine the intraobserver reliability of the ICRS grading system comparing arthroscopy and video assessment, and to compare the arthroscopic ICRS grading system with histological grading of lesion depth. Eighteen lesions in 5 cadaveric knee specimens were arthroscopically graded by 7 fellowship-trained arthroscopic surgeons using the ICRS classification system. The arthroscopic video of each lesion was sent to the surgeons 6 weeks later for repeat grading and determination of intraobserver reliability. Lesions were biopsied, and the depth of the cartilage lesion was assessed. Reliability was calculated using intraclass correlations. The interobserver reliability was 0.67 (95% confidence interval, 0.5-0.89) for the arthroscopic grading, and the intraobserver reliability with the video grading was 0.8 (95% confidence interval, 0.67-0.9). A high correlation was seen between the arthroscopic grading of depth and the histological grading of depth (0.91); on average, surgeons graded lesions using arthroscopy a mean of 0.37 (range, 0-0.86) deeper than the histological grade. The arthroscopic ICRS classification system has good interobserver and intraobserver reliability. A high correlation with histological assessment of depth provides evidence of validity for this classification system. As cartilage lesions are treated on the basis of the arthroscopic ICRS classification, it is important to ascertain the reliability and validity of this method. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  3. Activities of the DOE Nuclear Criticality Safety Program (NCSP) at the Oak Ridge Electron Linear Accelerator (ORELA)

    NASA Astrophysics Data System (ADS)

    Valentine, Timothy E.; Leal, Luiz C.; Guber, Klaus H.

    2002-12-01

    The Department of Energy established the Nuclear Criticality Safety Program (NCSP) in response to the Recommendation 97-2 by the Defense Nuclear Facilities Safety Board. The NCSP consists of seven elements of which nuclear data measurements and evaluations is a key component. The intent of the nuclear data activities is to provide high resolution nuclear data measurements that are evaluated, validated, and formatted for use by the nuclear criticality safety community to provide improved and reliable calculations for nuclear criticality safety evaluations. High resolution capture, fission, and transmission measurements are performed at the Oak Ridge Electron Linear Accelerator (ORELA) to address the needs of the criticality safety community and to address known deficiencies in nuclear data evaluations. The activities at ORELA include measurements on both light and heavy nuclei and have been used to identify improvements in measurement techniques that greatly improve the measurement of small capture cross sections. The measurement activities at ORELA provide precise and reliable high-resolution nuclear data for the nuclear criticality safety community.

  4. Size–strain separation in diffraction line profile analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scardi, P.; Ermrich, M.; Fitch, A.

    Separation of size and strain effects on diffraction line profiles has been studied in a round robin involving laboratory instruments and synchrotron radiation beamlines operating with different radiation, optics, detectors and experimental configurations. The studied sample, an extensively ball milled iron alloy powder, provides an ideal test case, as domain size broadening and strain broadening are of comparable size. The high energy available at some synchrotron radiation beamlines provides the best conditions for an accurate analysis of the line profiles, as the size–strain separation clearly benefits from a large number of Bragg peaks in the pattern; high counts, reliable intensitymore » values in low-absorption conditions, smooth background and data collection at different temperatures also support the possibility to include diffuse scattering in the analysis, for the most reliable assessment of the line broadening effect. However, results of the round robin show that good quality information on domain size distribution and microstrain can also be obtained using standard laboratory equipment, even when patterns include relatively few Bragg peaks, provided that the data are of good quality in terms of high counts and low and smooth background.« less

  5. Size–strain separation in diffraction line profile analysis

    DOE PAGES

    Scardi, P.; Ermrich, M.; Fitch, A.; ...

    2018-05-29

    Separation of size and strain effects on diffraction line profiles has been studied in a round robin involving laboratory instruments and synchrotron radiation beamlines operating with different radiation, optics, detectors and experimental configurations. The studied sample, an extensively ball milled iron alloy powder, provides an ideal test case, as domain size broadening and strain broadening are of comparable size. The high energy available at some synchrotron radiation beamlines provides the best conditions for an accurate analysis of the line profiles, as the size–strain separation clearly benefits from a large number of Bragg peaks in the pattern; high counts, reliable intensitymore » values in low-absorption conditions, smooth background and data collection at different temperatures also support the possibility to include diffuse scattering in the analysis, for the most reliable assessment of the line broadening effect. However, results of the round robin show that good quality information on domain size distribution and microstrain can also be obtained using standard laboratory equipment, even when patterns include relatively few Bragg peaks, provided that the data are of good quality in terms of high counts and low and smooth background.« less

  6. Impact of Co-Site Interference on L/C-Band Spectrum for UAS Control and Non-Payload Communications

    NASA Technical Reports Server (NTRS)

    Kerczewski, Robert J.; Bishop, William D.; Hoder, Douglas J.; Shalkhauser, Kurt A.; Wilson, Jeffrey D.

    2015-01-01

    In order to provide for the safe integration of unmanned aircraft systems into the National Airspace System, the control and non-payload communications (CNPC) link connecting the ground-based pilot with the unmanned aircraft must be highly reliable. A specific requirement is that it must operate using aviation safety radiofrequency spectrum. The 2012 World Radiocommunication Conference (WRC-12) provided a potentially suitable allocation for LOS CNPC spectrum in C-Band at 5030-5091 MHz band which, when combined with a previous allocation in L-Band (960-1164 MHz) may satisfy the LOS spectrum requirement and provide for high reliability through dual-band redundancy. However, the LBand spectrum hosts a number of aeronautical navigation systems which require high-power transmitters on-board the aircraft. These high-power transmitters co-located with sensitive CNPC receivers operating in the same frequency band have the potential to create co-site interference, reducing the performance of the CNPC receivers and ultimately reducing the usability of the L-Band for CNPC. This paper examines the potential for co-site interference, as highlighted in recent flight tests, and discusses the impact on the UAS CNPC spectrum availability and requirements for further testing and analysis.

  7. High pressure, high current, low inductance, high reliability sealed terminals

    DOEpatents

    Hsu, John S [Oak Ridge, TN; McKeever, John W [Oak Ridge, TN

    2010-03-23

    The invention is a terminal assembly having a casing with at least one delivery tapered-cone conductor and at least one return tapered-cone conductor routed there-through. The delivery and return tapered-cone conductors are electrically isolated from each other and positioned in the annuluses of ordered concentric cones at an off-normal angle. The tapered cone conductor service can be AC phase conductors and DC link conductors. The center core has at least one service conduit of gate signal leads, diagnostic signal wires, and refrigerant tubing routed there-through. A seal material is in direct contact with the casing inner surface, the tapered-cone conductors, and the service conduits thereby hermetically filling the interstitial space in the casing interior core and center core. The assembly provides simultaneous high-current, high-pressure, low-inductance, and high-reliability service.

  8. Optical detection of metastatic cancer cells using a scanned laser pico-projection system

    NASA Astrophysics Data System (ADS)

    Huang, Chih-Ling; Chiu, Wen-Tai; Lo, Yu-Lung; Chuang, Chin-Ho; Chen, Yu-Bin; Chang, Shu-Jing; Ke, Tung-Ting; Cheng, Hung-Chi; Wu, Hua-Lin

    2015-03-01

    Metastasis is responsible for 90% of all cancer-related deaths in humans. As a result, reliable techniques for detecting metastatic cells are urgently required. Although various techniques have been proposed for metastasis detection, they are generally capable of detecting metastatic cells only once migration has already occurred. Accordingly, the present study proposes an optical method for physical characterization of metastatic cancer cells using a scanned laser pico-projection system (SLPP). The validity of the proposed method is demonstrated using five pairs of cancer cell lines and two pairs of non-cancer cell lines treated by IPTG induction in order to mimic normal cells with an overexpression of oncogene. The results show that for all of the considered cell lines, the SLPP speckle contrast of the high-metastatic cells is significantly higher than that of the low-metastatic cells. As a result, the speckle contrast measurement provides a reliable means of distinguishing quantitatively between low- and high-metastatic cells of the same origin. Compared to existing metastasis detection methods, the proposed SLPP approach has many advantages, including a higher throughput, a lower cost, a larger sample size and a more reliable diagnostic performance. As a result, it provides a highly promising solution for physical characterization of metastatic cancer cells in vitro.

  9. [Kennedy V Axis assessment in an Italian outpatient and inpatient population].

    PubMed

    Mundo, Emanuela; Bonalume, Laura; Del Corno, Franco; Madeddu, Fabio; Lang, Margherita

    2010-01-01

    Kennedy Axis V or K Axis acts is an alternative tool to the DSM-IVTR Global Assessment of Functioning (GAF) Scale, that many researchers describe as a scale with poor inter-rater reliability and clinical utility. Unlike the GAF scale, K Axis provides a multidimensional and multiaxial approach to measure personal, social and interpersonal functioning in psychiatric outpatients and inpatients. In this study, we examined K Axis's inter-raters reliability by using it with an Italian clinical population. Clinicians used Kennedy Axis V to assess global functioning among 180 inpatients, in 9 psychiatric services in Lombardia and Piemonte. Patients were divided into 4 different diagnostic groups, according to the DSM-IV-TR criteria. Intraclass correlations between two independent raters's scores reveal high level of interrater reliability for all K Axis scales (0,633 < ICC < 0,813). Highly significant results in the Kruskal-Wallis test demonstrate that the patient diagnosis influence all the scales scores. Significant differences in patients functioning profiles in all K Axis scales, apart from Violence one, were noted between different diagnosis groups. In this study high level of raters agreement was noted, even if K Axis scales were used in different mental health services from different clinicians. K Axis scales provide a useful profile of patient global functioning, in line with the specific pathology.

  10. Intersession reliability of fMRI activation for heat pain and motor tasks

    PubMed Central

    Quiton, Raimi L.; Keaser, Michael L.; Zhuo, Jiachen; Gullapalli, Rao P.; Greenspan, Joel D.

    2014-01-01

    As the practice of conducting longitudinal fMRI studies to assess mechanisms of pain-reducing interventions becomes more common, there is a great need to assess the test–retest reliability of the pain-related BOLD fMRI signal across repeated sessions. This study quantitatively evaluated the reliability of heat pain-related BOLD fMRI brain responses in healthy volunteers across 3 sessions conducted on separate days using two measures: (1) intraclass correlation coefficients (ICC) calculated based on signal amplitude and (2) spatial overlap. The ICC analysis of pain-related BOLD fMRI responses showed fair-to-moderate intersession reliability in brain areas regarded as part of the cortical pain network. Areas with the highest intersession reliability based on the ICC analysis included the anterior midcingulate cortex, anterior insula, and second somatosensory cortex. Areas with the lowest intersession reliability based on the ICC analysis also showed low spatial reliability; these regions included pregenual anterior cingulate cortex, primary somatosensory cortex, and posterior insula. Thus, this study found regional differences in pain-related BOLD fMRI response reliability, which may provide useful information to guide longitudinal pain studies. A simple motor task (finger-thumb opposition) was performed by the same subjects in the same sessions as the painful heat stimuli were delivered. Intersession reliability of fMRI activation in cortical motor areas was comparable to previously published findings for both spatial overlap and ICC measures, providing support for the validity of the analytical approach used to assess intersession reliability of pain-related fMRI activation. A secondary finding of this study is that the use of standard ICC alone as a measure of reliability may not be sufficient, as the underlying variance structure of an fMRI dataset can result in inappropriately high ICC values; a method to eliminate these false positive results was used in this study and is recommended for future studies of test–retest reliability. PMID:25161897

  11. Improved electrode paste provides reliable measurement of galvanic skin response

    NASA Technical Reports Server (NTRS)

    Day, J. L.

    1966-01-01

    High-conductivity electrode paste is used in obtaining accurate skin resistance or skin potential measurements. The paste is isotonic to perspiration, is nonirritating and nonsensitizing, and has an extended shelf life.

  12. A comparative reliability analysis of free-piston Stirling machines

    NASA Astrophysics Data System (ADS)

    Schreiber, Jeffrey G.

    2001-02-01

    A free-piston Stirling power convertor is being developed for use in an advanced radioisotope power system to provide electric power for NASA deep space missions. These missions are typically long lived, lasting for up to 14 years. The Department of Energy (DOE) is responsible for providing the radioisotope power system for the NASA missions, and has managed the development of the free-piston power convertor for this application. The NASA Glenn Research Center has been involved in the development of Stirling power conversion technology for over 25 years and is currently providing support to DOE. Due to the nature of the potential missions, long life and high reliability are important features for the power system. Substantial resources have been spent on the development of long life Stirling cryocoolers for space applications. As a very general statement, free-piston Stirling power convertors have many features in common with free-piston Stirling cryocoolers, however there are also significant differences. For example, designs exist for both power convertors and cryocoolers that use the flexure bearing support system to provide noncontacting operation of the close-clearance moving parts. This technology and the operating experience derived from one application may be readily applied to the other application. This similarity does not pertain in the case of outgassing and contamination. In the cryocooler, the contaminants normally condense in the critical heat exchangers and foul the performance. In the Stirling power convertor just the opposite is true as contaminants condense on non-critical surfaces. A methodology was recently published that provides a relative comparison of reliability, and is applicable to systems. The methodology has been applied to compare the reliability of a Stirling cryocooler relative to that of a free-piston Stirling power convertor. The reliability analysis indicates that the power convertor should be able to have superior reliability compared to the cryocooler. .

  13. Reliability and validity of migraine disability assessment questionnaire-Thai version (Thai-MIDAS).

    PubMed

    Seethong, Piman; Nimmannit, Akarin; Chaisewikul, Rungsan; Prayoonwiwat, Naraporn; Chotinaiwattarakul, Wattanachai

    2013-02-01

    To assess the validity and test-retest reliability of a Thai translation of the Migraine Disability Assessment (MIDAS) Questionnaire in Thai patients with migraine. Migraineurs from the Headache Clinic in Siriraj Hospital were recruited and asked to complete a 13-weeks diary and answered the Thai-MIDAS at once. Some participants were asked to provide the 2nd Thai-MIDAS in the next 2 weeks for test-retest reliability. Ninety-three patients had completed the 13-weeks diaries. Age range was 18-58 years with mean 37.69 +/- 9.60 years. All 5 items and the total score of Thai-MIDAS were moderately correlated with data from 13-weeks diary (Spearman's correlation coefficient = 0.32-0.62). The test-retest reliability of the total score of Thai-MIDAS in 30 patients demonstrated a highly reliable degree of intraclass correlation (ICC = 0.76, 95% CI 0.49-0.88). The present study reveals that the Thai-MIDAS has satisfactory validity and reliability in comparison with the original English MIDAS version.

  14. Comparative Analysis of NOAA REFM and SNB3GEO Tools for the Forecast of the Fluxes of High-Energy Electrons at GEO

    NASA Technical Reports Server (NTRS)

    Balikhin, M. A.; Rodriguez, J. V.; Boynton, R. J.; Walker, S. N.; Aryan, Homayon; Sibeck, D. G.; Billings, S. A.

    2016-01-01

    Reliable forecasts of relativistic electrons at geostationary orbit (GEO) are important for the mitigation of their hazardous effects on spacecraft at GEO. For a number of years the Space Weather Prediction Center at NOAA has provided advanced online forecasts of the fluence of electrons with energy >2 MeV at GEO using the Relativistic Electron Forecast Model (REFM). The REFM forecasts are based on real-time solar wind speed observations at L1. The high reliability of this forecasting tool serves as a benchmark for the assessment of other forecasting tools. Since 2012 the Sheffield SNB3GEO model has been operating online, providing a 24 h ahead forecast of the same fluxes. In addition to solar wind speed, the SNB3GEO forecasts use solar wind density and interplanetary magnetic field B(sub z) observations at L1. The period of joint operation of both of these forecasts has been used to compare their accuracy. Daily averaged measurements of electron fluxes by GOES 13 have been used to estimate the prediction efficiency of both forecasting tools. To assess the reliability of both models to forecast infrequent events of very high fluxes, the Heidke skill score was employed. The results obtained indicate that SNB3GEO provides a more accurate 1 day ahead forecast when compared to REFM. It is shown that the correction methodology utilized by REFM potentially can improve the SNB3GEO forecast.

  15. Comparative analysis of NOAA REFM and SNB3GEO tools for the forecast of the fluxes of high-energy electrons at GEO.

    PubMed

    Balikhin, M A; Rodriguez, J V; Boynton, R J; Walker, S N; Aryan, H; Sibeck, D G; Billings, S A

    2016-01-01

    Reliable forecasts of relativistic electrons at geostationary orbit (GEO) are important for the mitigation of their hazardous effects on spacecraft at GEO. For a number of years the Space Weather Prediction Center at NOAA has provided advanced online forecasts of the fluence of electrons with energy >2 MeV at GEO using the Relativistic Electron Forecast Model (REFM). The REFM forecasts are based on real-time solar wind speed observations at L1. The high reliability of this forecasting tool serves as a benchmark for the assessment of other forecasting tools. Since 2012 the Sheffield SNB 3 GEO model has been operating online, providing a 24 h ahead forecast of the same fluxes. In addition to solar wind speed, the SNB 3 GEO forecasts use solar wind density and interplanetary magnetic field B z observations at L1.The period of joint operation of both of these forecasts has been used to compare their accuracy. Daily averaged measurements of electron fluxes by GOES 13 have been used to estimate the prediction efficiency of both forecasting tools. To assess the reliability of both models to forecast infrequent events of very high fluxes, the Heidke skill score was employed. The results obtained indicate that SNB 3 GEO provides a more accurate 1 day ahead forecast when compared to REFM. It is shown that the correction methodology utilized by REFM potentially can improve the SNB 3 GEO forecast.

  16. Validity and reliability assessment of a peer evaluation method in team-based learning classes.

    PubMed

    Yoon, Hyun Bae; Park, Wan Beom; Myung, Sun-Jung; Moon, Sang Hui; Park, Jun-Bean

    2018-03-01

    Team-based learning (TBL) is increasingly employed in medical education because of its potential to promote active group learning. In TBL, learners are usually asked to assess the contributions of peers within their group to ensure accountability. The purpose of this study is to assess the validity and reliability of a peer evaluation instrument that was used in TBL classes in a single medical school. A total of 141 students were divided into 18 groups in 11 TBL classes. The students were asked to evaluate their peers in the group based on evaluation criteria that were provided to them. We analyzed the comments that were written for the highest and lowest achievers to assess the validity of the peer evaluation instrument. The reliability of the instrument was assessed by examining the agreement among peer ratings within each group of students via intraclass correlation coefficient (ICC) analysis. Most of the students provided reasonable and understandable comments for the high and low achievers within their group, and most of those comments were compatible with the evaluation criteria. The average ICC of each group ranged from 0.390 to 0.863, and the overall average was 0.659. There was no significant difference in inter-rater reliability according to the number of members in the group or the timing of the evaluation within the course. The peer evaluation instrument that was used in the TBL classes was valid and reliable. Providing evaluation criteria and rules seemed to improve the validity and reliability of the instrument.

  17. Economic Attitudes of High School Students: New Norms for the "Survey on Economic Attitudes."

    ERIC Educational Resources Information Center

    Soper, John C.; Walstad, William B.

    1988-01-01

    Explores the reliability and validity of an affective domain instrument, the "Survey on Economic Attitudes," by providing new norms and a discussion of the properties of the national sample of high school students used. Presents current information about the economic attitudes of U.S. high school students and raises some important…

  18. Who Are Most, Average, or High-Functioning Adults?

    ERIC Educational Resources Information Center

    Gregg, Noel; Coleman, Chris; Lindstrom, Jennifer; Lee, Christopher

    2007-01-01

    The growing number of high-functioning adults seeking accommodations from testing agencies and postsecondary institutions presents an urgent need to ensure reliable and valid diagnostic decision making. The potential for this population to make significant contributions to society will be greater if we provide the learning and testing…

  19. GaAs Monolithic Microwave Subsystem Technology Base

    DTIC Science & Technology

    1980-01-01

    To provide a captive source of reliable, high-quality GaAs substrates, a new crystal growth and substrate preparation facility which utilizes a high...Symp. GaAs and Related Compounds, Inst. Phys. Conf. Ser. 24, 6. 20. Wood, Woodcock and Harris (1978) GaAs and Related Compounds, Inst. Phys. Conf

  20. Thin-Slice Perception Develops Slowly

    ERIC Educational Resources Information Center

    Balas, Benjamin; Kanwisher, Nancy; Saxe, Rebecca

    2012-01-01

    Body language and facial gesture provide sufficient visual information to support high-level social inferences from "thin slices" of behavior. Given short movies of nonverbal behavior, adults make reliable judgments in a large number of tasks. Here we find that the high precision of adults' nonverbal social perception depends on the slow…

  1. Tapping unsustainable groundwater stores for agricultural production in the High Plains Aquifer of Kansas, projections to 2110

    USDA-ARS?s Scientific Manuscript database

    Groundwater provides a reliable tap to sustain agricultural production, yet persistent aquifer depletion threatens future sustainability. The High Plains Aquifer supplies 30% of the nation’s irrigated groundwater, and the Kansas portion supports the congressional district with the highest market val...

  2. Guide to Developing High-Quality, Reliable, and Valid Multiple-Choice Assessments

    ERIC Educational Resources Information Center

    Towns, Marcy H.

    2014-01-01

    Chemistry faculty members are highly skilled in obtaining, analyzing, and interpreting physical measurements, but often they are less skilled in measuring student learning. This work provides guidance for chemistry faculty from the research literature on multiple-choice item development in chemistry. Areas covered include content, stem, and…

  3. The Verification-based Analysis of Reliable Multicast Protocol

    NASA Technical Reports Server (NTRS)

    Wu, Yunqing

    1996-01-01

    Reliable Multicast Protocol (RMP) is a communication protocol that provides an atomic, totally ordered, reliable multicast service on top of unreliable IP Multicasting. In this paper, we develop formal models for R.W using existing automatic verification systems, and perform verification-based analysis on the formal RMP specifications. We also use the formal models of RW specifications to generate a test suite for conformance testing of the RMP implementation. Throughout the process of RMP development, we follow an iterative, interactive approach that emphasizes concurrent and parallel progress between the implementation and verification processes. Through this approach, we incorporate formal techniques into our development process, promote a common understanding for the protocol, increase the reliability of our software, and maintain high fidelity between the specifications of RMP and its implementation.

  4. Feasibility model of a high reliability five-year tape transport, Volume 1. [development, performance, and test results

    NASA Technical Reports Server (NTRS)

    Eshleman, R. L.; Meyers, A. P.; Davidson, W. A.; Gortowski, R. C.; Anderson, M. E.

    1973-01-01

    The development, performance, and test results for the spaceborne magnetic tape transport are discussed. An analytical model of the tape transport was used to optimize its conceptual design. Each of the subsystems was subjected to reliability analyses which included structural integrity, maintenance of system performance within acceptable bounds, and avoidance of fatigue failure. These subsystems were also compared with each other in order to evaluate reliability characteristics. The transport uses no mechanical couplings. Four drive motors, one for each reel and one for each of two capstans, are used in a differential mode. There are two hybrid, spherical, cone tapered-crown rollers for tape guidance. Storage of the magnetic tape is provided by a reel assembly which includes the reel, a reel support structure and bearings, dust seals, and a dc drive motor. A summary of transport test results on tape guidance, flutter, and skew is provided.

  5. Engineering Design Handbook. Development Guide for Reliability. Part Two. Design for Reliability

    DTIC Science & Technology

    1976-01-01

    Component failure rates, however, have been recorded by many sources as a function of use and environment. Some of these sources are listed in Refs. 13-17...other systems capable of creating an explosive reac- tion. The second category is fairly obvious and includes many variations on methods for providing...aboutthem. 4. Ability to detect signals ( including patterns) in high noise environments. 5. Ability to store large amounts of informa- tion for long

  6. Reliability Assessment Approach for Stirling Convertors and Generators

    NASA Technical Reports Server (NTRS)

    Shah, Ashwin R.; Schreiber, Jeffrey G.; Zampino, Edward; Best, Timothy

    2004-01-01

    Stirling power conversion is being considered for use in a Radioisotope Power System for deep-space science missions because it offers a multifold increase in the conversion efficiency of heat to electric power. Quantifying the reliability of a Radioisotope Power System that utilizes Stirling power conversion technology is important in developing and demonstrating the capability for long-term success. A description of the Stirling power convertor is provided, along with a discussion about some of the key components. Ongoing efforts to understand component life, design variables at the component and system levels, related sources, and the nature of uncertainties is discussed. The requirement for reliability also is discussed, and some of the critical areas of concern are identified. A section on the objectives of the performance model development and a computation of reliability is included to highlight the goals of this effort. Also, a viable physics-based reliability plan to model the design-level variable uncertainties at the component and system levels is outlined, and potential benefits are elucidated. The plan involves the interaction of different disciplines, maintaining the physical and probabilistic correlations at all the levels, and a verification process based on rational short-term tests. In addition, both top-down and bottom-up coherency were maintained to follow the physics-based design process and mission requirements. The outlined reliability assessment approach provides guidelines to improve the design and identifies governing variables to achieve high reliability in the Stirling Radioisotope Generator design.

  7. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD.

    PubMed

    Formiga, Magno F; Roach, Kathryn E; Vital, Isabel; Urdaneta, Gisel; Balestrini, Kira; Calderon-Candelario, Rafael A; Campos, Michael A; Cahalin, Lawrence P

    2018-01-01

    The Test of Incremental Respiratory Endurance (TIRE) provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP) over time. The integration of MIP over inspiratory duration (ID) provides the sustained maximal inspiratory pressure (SMIP). Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Test-retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test-retest reliability with a nearly perfect intraclass correlation coefficient (ICC) of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP and ID, but not MIP. The TIRE measures of MIP, SMIP and ID have excellent test-retest reliability and demonstrated known-groups validity in subjects with COPD. SMIP and ID also demonstrated evidence of moderate convergent validity and appear to be more stable measures in this patient population than the traditional MIP.

  8. The Reliability of a Three-Dimensional Photo System- (3dMDface-) Based Evaluation of the Face in Cleft Lip Infants

    PubMed Central

    Ort, Rebecca; Metzler, Philipp; Kruse, Astrid L.; Matthews, Felix; Zemann, Wolfgang; Grätz, Klaus W.; Luebbers, Heinz-Theo

    2012-01-01

    Ample data exists about the high precision of three-dimensional (3D) scanning devices and their data acquisition of the facial surface. However, a question remains regarding which facial landmarks are reliable if identified in 3D images taken under clinical circumstances. Sources of error to be addressed could be technical, user dependent, or patient respectively anatomy related. Based on clinical 3D photos taken with the 3dMDface system, the intra observer repeatability of 27 facial landmarks in six cleft lip (CL) infants and one non-CL infant was evaluated based on a total of over 1,100 measurements. Data acquisition was sometimes challenging but successful in all patients. The mean error was 0.86 mm, with a range of 0.39 mm (Exocanthion) to 2.21 mm (soft gonion). Typically, landmarks provided a small mean error but still showed quite a high variance in measurements, for example, exocanthion from 0.04 mm to 0.93 mm. Vice versa, relatively imprecise landmarks still provide accurate data regarding specific spatial planes. One must be aware of the fact that the degree of precision is dependent on landmarks and spatial planes in question. In clinical investigations, the degree of reliability for landmarks evaluated should be taken into account. Additional reliability can be achieved via multiple measuring. PMID:22919476

  9. Constraining uncertainties in water supply reliability in a tropical data scarce basin

    NASA Astrophysics Data System (ADS)

    Kaune, Alexander; Werner, Micha; Rodriguez, Erasmo; de Fraiture, Charlotte

    2015-04-01

    Assessing the water supply reliability in river basins is essential for adequate planning and development of irrigated agriculture and urban water systems. In many cases hydrological models are applied to determine the surface water availability in river basins. However, surface water availability and variability is often not appropriately quantified due to epistemic uncertainties, leading to water supply insecurity. The objective of this research is to determine the water supply reliability in order to support planning and development of irrigated agriculture in a tropical, data scarce environment. The approach proposed uses a simple hydrological model, but explicitly includes model parameter uncertainty. A transboundary river basin in the tropical region of Colombia and Venezuela with an approximately area of 2100 km² was selected as a case study. The Budyko hydrological framework was extended to consider climatological input variability and model parameter uncertainty, and through this the surface water reliability to satisfy the irrigation and urban demand was estimated. This provides a spatial estimate of the water supply reliability across the basin. For the middle basin the reliability was found to be less than 30% for most of the months when the water is extracted from an upstream source. Conversely, the monthly water supply reliability was high (r>98%) in the lower basin irrigation areas when water was withdrawn from a source located further downstream. Including model parameter uncertainty provides a complete estimate of the water supply reliability, but that estimate is influenced by the uncertainty in the model. Reducing the uncertainty in the model through improved data and perhaps improved model structure will improve the estimate of the water supply reliability allowing better planning of irrigated agriculture and dependable water allocation decisions.

  10. Distribution System Reliability Analysis for Smart Grid Applications

    NASA Astrophysics Data System (ADS)

    Aljohani, Tawfiq Masad

    Reliability of power systems is a key aspect in modern power system planning, design, and operation. The ascendance of the smart grid concept has provided high hopes of developing an intelligent network that is capable of being a self-healing grid, offering the ability to overcome the interruption problems that face the utility and cost it tens of millions in repair and loss. To address its reliability concerns, the power utilities and interested parties have spent extensive amount of time and effort to analyze and study the reliability of the generation and transmission sectors of the power grid. Only recently has attention shifted to be focused on improving the reliability of the distribution network, the connection joint between the power providers and the consumers where most of the electricity problems occur. In this work, we will examine the effect of the smart grid applications in improving the reliability of the power distribution networks. The test system used in conducting this thesis is the IEEE 34 node test feeder, released in 2003 by the Distribution System Analysis Subcommittee of the IEEE Power Engineering Society. The objective is to analyze the feeder for the optimal placement of the automatic switching devices and quantify their proper installation based on the performance of the distribution system. The measures will be the changes in the reliability system indices including SAIDI, SAIFI, and EUE. The goal is to design and simulate the effect of the installation of the Distributed Generators (DGs) on the utility's distribution system and measure the potential improvement of its reliability. The software used in this work is DISREL, which is intelligent power distribution software that is developed by General Reliability Co.

  11. Column Grid Array Rework for High Reliability

    NASA Technical Reports Server (NTRS)

    Mehta, Atul C.; Bodie, Charles C.

    2008-01-01

    Due to requirements for reduced size and weight, use of grid array packages in space applications has become common place. To meet the requirement of high reliability and high number of I/Os, ceramic column grid array packages (CCGA) were selected for major electronic components used in next MARS Rover mission (specifically high density Field Programmable Gate Arrays). ABSTRACT The probability of removal and replacement of these devices on the actual flight printed wiring board assemblies is deemed to be very high because of last minute discoveries in final test which will dictate changes in the firmware. The questions and challenges presented to the manufacturing organizations engaged in the production of high reliability electronic assemblies are, Is the reliability of the PWBA adversely affected by rework (removal and replacement) of the CGA package? and How many times can we rework the same board without destroying a pad or degrading the lifetime of the assembly? To answer these questions, the most complex printed wiring board assembly used by the project was chosen to be used as the test vehicle, the PWB was modified to provide a daisy chain pattern, and a number of bare PWB s were acquired to this modified design. Non-functional 624 pin CGA packages with internal daisy chained matching the pattern on the PWB were procured. The combination of the modified PWB and the daisy chained packages enables continuity measurements of every soldered contact during subsequent testing and thermal cycling. Several test vehicles boards were assembled, reworked and then thermal cycled to assess the reliability of the solder joints and board material including pads and traces near the CGA. The details of rework process and results of thermal cycling are presented in this paper.

  12. The Healthy Brain Network Serial Scanning Initiative: a resource for evaluating inter-individual differences and their reliabilities across scan conditions and sessions.

    PubMed

    O'Connor, David; Potler, Natan Vega; Kovacs, Meagan; Xu, Ting; Ai, Lei; Pellman, John; Vanderwal, Tamara; Parra, Lucas C; Cohen, Samantha; Ghosh, Satrajit; Escalera, Jasmine; Grant-Villegas, Natalie; Osman, Yael; Bui, Anastasia; Craddock, R Cameron; Milham, Michael P

    2017-02-01

    Although typically measured during the resting state, a growing literature is illustrating the ability to map intrinsic connectivity with functional MRI during task and naturalistic viewing conditions. These paradigms are drawing excitement due to their greater tolerability in clinical and developing populations and because they enable a wider range of analyses (e.g., inter-subject correlations). To be clinically useful, the test-retest reliability of connectivity measured during these paradigms needs to be established. This resource provides data for evaluating test-retest reliability for full-brain connectivity patterns detected during each of four scan conditions that differ with respect to level of engagement (rest, abstract animations, movie clips, flanker task). Data are provided for 13 participants, each scanned in 12 sessions with 10 minutes for each scan of the four conditions. Diffusion kurtosis imaging data was also obtained at each session. Technical validation and demonstrative reliability analyses were carried out at the connection-level using the Intraclass Correlation Coefficient and at network-level representations of the data using the Image Intraclass Correlation Coefficient. Variation in intrinsic functional connectivity across sessions was generally found to be greater than that attributable to scan condition. Between-condition reliability was generally high, particularly for the frontoparietal and default networks. Between-session reliabilities obtained separately for the different scan conditions were comparable, though notably lower than between-condition reliabilities. This resource provides a test-bed for quantifying the reliability of connectivity indices across subjects, conditions and time. The resource can be used to compare and optimize different frameworks for measuring connectivity and data collection parameters such as scan length. Additionally, investigators can explore the unique perspectives of the brain's functional architecture offered by each of the scan conditions. © The Author 2017. Published by Oxford University Press.

  13. High-resolution audiometry: an automated method for hearing threshold acquisition with quality control.

    PubMed

    Bian, Lin

    2012-01-01

    In clinical practice, hearing thresholds are measured at only five to six frequencies at octave intervals. Thus, the audiometric configuration cannot closely reflect the actual status of the auditory structures. In addition, differential diagnosis requires quantitative comparison of behavioral thresholds with physiological measures, such as otoacoustic emissions (OAEs) that are usually measured in higher resolution. The purpose of this research was to develop a method to improve the frequency resolution of the audiogram. A repeated-measure design was used in the study to evaluate the reliability of the threshold measurements. A total of 16 participants with clinically normal hearing and mild hearing loss were recruited from a population of university students. No intervention was involved in the study. Custom developed system and software were used for threshold acquisition with quality control (QC). With real-ear calibration and monitoring of test signals, the system provided accurate and individualized measure of hearing thresholds that were determined by an analysis based on signal detection theory (SDT). The reliability of the threshold measure was assessed by correlation and differences between the repeated measures. The audiometric configurations were diverse and unique to each individual ear. The accuracy, within-subject reliability, and between-test repeatability are relatively high. With QC, the high-resolution audiograms can be reliably and accurately measured. Hearing thresholds measured as ear canal sound pressures with higher frequency resolution can provide more customized hearing-aid fitting. The test system may be integrated with other physiological measures, such as OAEs, into a comprehensive evaluative tool. American Academy of Audiology.

  14. Inter-examiner classification reliability of Mechanical Diagnosis and Therapy for extremity problems - Systematic review.

    PubMed

    Takasaki, Hiroshi; Okuyama, Kousuke; Rosedale, Richard

    2017-02-01

    Mechanical Diagnosis and Therapy (MDT) is used in the treatment of extremity problems. Classifying clinical problems is one method of providing effective treatment to a target population. Classification reliability is a key factor to determine the precise clinical problem and to direct an appropriate intervention. To explore inter-examiner reliability of the MDT classification for extremity problems in three reliability designs: 1) vignette reliability using surveys with patient vignettes, 2) concurrent reliability, where multiple assessors decide a classification by observing someone's assessment, 3) successive reliability, where multiple assessors independently assess the same patient at different times. Systematic review with data synthesis in a quantitative format. Agreement of MDT subgroups was examined using the Kappa value, with the operational definition of acceptable reliability set at ≥ 0.6. The level of evidence was determined considering the methodological quality of the studies. Six studies were included and all studies met the criteria for high quality. Kappa values for the vignette reliability design (five studies) were ≥ 0.7. There was data from two cohorts in one study for the concurrent reliability design and the Kappa values ranged from 0.45 to 1.0. Kappa values for the successive reliability design (data from three cohorts in one study) were < 0.6. The current review found strong evidence of acceptable inter-examiner reliability of MDT classification for extremity problems in the vignette reliability design, limited evidence of acceptable reliability in the concurrent reliability design and unacceptable reliability in the successive reliability design. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. First Stage of a Highly Reliable Reusable Launch System

    NASA Technical Reports Server (NTRS)

    Kloesel, Kurt J.; Pickrel, Jonathan B.; Sayles, Emily L.; Wright, Michael; Marriott, Darin; Holland, Leo; Kuznetsov, Stephen

    2009-01-01

    Electromagnetic launch assist has the potential to provide a highly reliable reusable first stage to a space access system infrastructure at a lower overall cost. This paper explores the benefits of a smaller system that adds the advantages of a high specific impulse air-breathing stage and supersonic launch speeds. The method of virtual specific impulse is introduced as a tool to emphasize the gains afforded by launch assist. Analysis shows launch assist can provide a 278-s virtual specific impulse for a first-stage solid rocket. Additional trajectory analysis demonstrates that a system composed of a launch-assisted first-stage ramjet plus a bipropellant second stage can provide a 48-percent gross lift-off weight reduction versus an all-rocket system. The combination of high-speed linear induction motors and ramjets is identified, as the enabling technologies and benchtop prototypes are investigated. The high-speed response of a standard 60 Hz linear induction motor was tested with a pulse width modulated variable frequency drive to 150 Hz using a 10-lb load, achieving 150 mph. A 300-Hz stator-compensated linear induction motor was constructed and static-tested to 1900 lbf average. A matching ramjet design was developed for use on the 300-Hz linear induction motor.

  16. Design of reliable universal QCA logic in the presence of cell deposition defect

    NASA Astrophysics Data System (ADS)

    Sen, Bibhash; Mukherjee, Rijoy; Mohit, Kumar; Sikdar, Biplab K.

    2017-08-01

    The emergence of Quantum-dot Cellular Automata (QCA) has resulted in being identified as a promising alternative to the currently prevailing techniques of very large scale integration. QCA can provide low-power nanocircuit with high device density. Keeping aside the profound acceptance of QCA, the challenge that it is facing can be quoted as susceptibility to high error rate. The work produced in this article aims towards the design of a reliable universal logic gate (r-ULG) in QCA (r-ULG along with the single clock zone and r-ULG-II along with multiple clock zones). The design would include hybrid orientation of cells that would realise majority and minority, functions and high fault tolerance simultaneously. The characterisation of the defective behaviour of r-ULGs under different kinds of cell deposition defects is investigated. The outcomes of the investigation provide an indication that the proposed r-ULG provides a fault tolerance of 75% under single clock zone and a fault tolerance of 100% under dual clock zones. The high functional aspects of r-ULGs in the implementation of different logic functions successfully under cell deposition defects are affirmed by the experimental results. The high-level logic around the multiplexer is synthesised, which helps to extend the design capability to the higher-level circuit synthesis.

  17. INFLUENCES OF RESPONSE RATE AND DISTRIBUTION ON THE CALCULATION OF INTEROBSERVER RELIABILITY SCORES

    PubMed Central

    Rolider, Natalie U.; Iwata, Brian A.; Bullock, Christopher E.

    2012-01-01

    We examined the effects of several variations in response rate on the calculation of total, interval, exact-agreement, and proportional reliability indices. Trained observers recorded computer-generated data that appeared on a computer screen. In Study 1, target responses occurred at low, moderate, and high rates during separate sessions so that reliability results based on the four calculations could be compared across a range of values. Total reliability was uniformly high, interval reliability was spuriously high for high-rate responding, proportional reliability was somewhat lower for high-rate responding, and exact-agreement reliability was the lowest of the measures, especially for high-rate responding. In Study 2, we examined the separate effects of response rate per se, bursting, and end-of-interval responding. Response rate and bursting had little effect on reliability scores; however, the distribution of some responses at the end of intervals decreased interval reliability somewhat, proportional reliability noticeably, and exact-agreement reliability markedly. PMID:23322930

  18. Monkeys and humans take local uncertainty into account when localizing a change.

    PubMed

    Devkar, Deepna; Wright, Anthony A; Ma, Wei Ji

    2017-09-01

    Since sensory measurements are noisy, an observer is rarely certain about the identity of a stimulus. In visual perception tasks, observers generally take their uncertainty about a stimulus into account when doing so helps task performance. Whether the same holds in visual working memory tasks is largely unknown. Ten human and two monkey subjects localized a single change in orientation between a sample display containing three ellipses and a test display containing two ellipses. To manipulate uncertainty, we varied the reliability of orientation information by making each ellipse more or less elongated (two levels); reliability was independent across the stimuli. In both species, a variable-precision encoding model equipped with an "uncertainty-indifferent" decision rule, which uses only the noisy memories, fitted the data poorly. In both species, a much better fit was provided by a model in which the observer also takes the levels of reliability-driven uncertainty associated with the memories into account. In particular, a measured change in a low-reliability stimulus was given lower weight than the same change in a high-reliability stimulus. We did not find strong evidence that observers took reliability-independent variations in uncertainty into account. Our results illustrate the importance of studying the decision stage in comparison tasks and provide further evidence for evolutionary continuity of working memory systems between monkeys and humans.

  19. Monkeys and humans take local uncertainty into account when localizing a change

    PubMed Central

    Devkar, Deepna; Wright, Anthony A.; Ma, Wei Ji

    2017-01-01

    Since sensory measurements are noisy, an observer is rarely certain about the identity of a stimulus. In visual perception tasks, observers generally take their uncertainty about a stimulus into account when doing so helps task performance. Whether the same holds in visual working memory tasks is largely unknown. Ten human and two monkey subjects localized a single change in orientation between a sample display containing three ellipses and a test display containing two ellipses. To manipulate uncertainty, we varied the reliability of orientation information by making each ellipse more or less elongated (two levels); reliability was independent across the stimuli. In both species, a variable-precision encoding model equipped with an “uncertainty–indifferent” decision rule, which uses only the noisy memories, fitted the data poorly. In both species, a much better fit was provided by a model in which the observer also takes the levels of reliability-driven uncertainty associated with the memories into account. In particular, a measured change in a low-reliability stimulus was given lower weight than the same change in a high-reliability stimulus. We did not find strong evidence that observers took reliability-independent variations in uncertainty into account. Our results illustrate the importance of studying the decision stage in comparison tasks and provide further evidence for evolutionary continuity of working memory systems between monkeys and humans. PMID:28877535

  20. Do you see what I see? Mobile eye-tracker contextual analysis and inter-rater reliability.

    PubMed

    Stuart, S; Hunt, D; Nell, J; Godfrey, A; Hausdorff, J M; Rochester, L; Alcock, L

    2018-02-01

    Mobile eye-trackers are currently used during real-world tasks (e.g. gait) to monitor visual and cognitive processes, particularly in ageing and Parkinson's disease (PD). However, contextual analysis involving fixation locations during such tasks is rarely performed due to its complexity. This study adapted a validated algorithm and developed a classification method to semi-automate contextual analysis of mobile eye-tracking data. We further assessed inter-rater reliability of the proposed classification method. A mobile eye-tracker recorded eye-movements during walking in five healthy older adult controls (HC) and five people with PD. Fixations were identified using a previously validated algorithm, which was adapted to provide still images of fixation locations (n = 116). The fixation location was manually identified by two raters (DH, JN), who classified the locations. Cohen's kappa correlation coefficients determined the inter-rater reliability. The algorithm successfully provided still images for each fixation, allowing manual contextual analysis to be performed. The inter-rater reliability for classifying the fixation location was high for both PD (kappa = 0.80, 95% agreement) and HC groups (kappa = 0.80, 91% agreement), which indicated a reliable classification method. This study developed a reliable semi-automated contextual analysis method for gait studies in HC and PD. Future studies could adapt this methodology for various gait-related eye-tracking studies.

  1. A cascaded coding scheme for error control and its performance analysis

    NASA Technical Reports Server (NTRS)

    Lin, S.

    1986-01-01

    A coding scheme for error control in data communication systems is investigated. The scheme is obtained by cascading two error correcting codes, called the inner and the outer codes. The error performance of the scheme is analyzed for a binary symmetric channel with bit error rate epsilon < 1/2. It is shown that, if the inner and outer codes are chosen properly, extremely high reliability can be attained even for a high channel bit error rate. Various specific example schemes with inner codes ranging from high rates to very low rates and Reed-Solomon codes are considered, and their probabilities are evaluated. They all provide extremely high reliability even for very high bit error rates, say 0.1 to 0.01. Several example schemes are being considered by NASA for satellite and spacecraft down link error control.

  2. A cascaded coding scheme for error control and its performance analysis

    NASA Technical Reports Server (NTRS)

    Lin, Shu; Kasami, Tadao; Fujiwara, Tohru; Takata, Toyoo

    1986-01-01

    A coding scheme is investigated for error control in data communication systems. The scheme is obtained by cascading two error correcting codes, called the inner and outer codes. The error performance of the scheme is analyzed for a binary symmetric channel with bit error rate epsilon <1/2. It is shown that if the inner and outer codes are chosen properly, extremely high reliability can be attained even for a high channel bit error rate. Various specific example schemes with inner codes ranging form high rates to very low rates and Reed-Solomon codes as inner codes are considered, and their error probabilities are evaluated. They all provide extremely high reliability even for very high bit error rates. Several example schemes are being considered by NASA for satellite and spacecraft down link error control.

  3. Universal first-order reliability concept applied to semistatic structures

    NASA Technical Reports Server (NTRS)

    Verderaime, V.

    1994-01-01

    A reliability design concept was developed for semistatic structures which combines the prevailing deterministic method with the first-order reliability method. The proposed method surmounts deterministic deficiencies in providing uniformly reliable structures and improved safety audits. It supports risk analyses and reliability selection criterion. The method provides a reliability design factor derived from the reliability criterion which is analogous to the current safety factor for sizing structures and verifying reliability response. The universal first-order reliability method should also be applicable for air and surface vehicles semistatic structures.

  4. Universal first-order reliability concept applied to semistatic structures

    NASA Astrophysics Data System (ADS)

    Verderaime, V.

    1994-07-01

    A reliability design concept was developed for semistatic structures which combines the prevailing deterministic method with the first-order reliability method. The proposed method surmounts deterministic deficiencies in providing uniformly reliable structures and improved safety audits. It supports risk analyses and reliability selection criterion. The method provides a reliability design factor derived from the reliability criterion which is analogous to the current safety factor for sizing structures and verifying reliability response. The universal first-order reliability method should also be applicable for air and surface vehicles semistatic structures.

  5. Small Aerostationary Telecommunications Orbiter Concept for Mars in the 2020s

    NASA Technical Reports Server (NTRS)

    Lock, Robert E.; Edwards, Charles D., Jr.; Nicholas, Austin; Woolley, Ryan; Bell, David J.

    2016-01-01

    Current Mars science orbiters carry UHF proximity payloads to provide limited access and data services to landers and rovers on Mars surface. In the era of human spaceflight to Mars, very high rate and reliable relay services will be needed to serve a large number of supporting vehicles, habitats, and orbiters, as well as astronaut EVAs. These will likely be provided by a robust network of orbiting assets in very high orbits, such as areostationary orbits. In the decade leading to that era, telecommunications orbits can be operated at areostationary orbit that can support a significant population of robotic precursor missions and build the network capabilities needed for the human spaceflight era. Telecommunications orbiters of modest size and cost, delivered by Solar Electric Propulsion to areostationary orbit, can provide continuous access at very high data rates to users on the surface and in Mars orbit.In the era of human spaceflight to Mars very high rate andreliable relay services will be needed to serve a largenumber of supporting vehicles, habitats, and orbiters, aswell as astronaut EVAs. These could be provided by arobust network of orbiting assets in very high orbits. In thedecade leading to that era, telecommunications orbiterscould be operated at areostationary orbit that could support asignificant population of robotic precursor missions andbuild the network capabilities needed for the humanspaceflight era. These orbiters could demonstrate thecapabilities and services needed for the future but withoutthe high bandwidth and high reliability requirements neededfor human spaceflight.Telecommunications orbiters of modest size and cost,delivered by Solar Electric Propulsion to areostationaryorbit, could provide continuous access at very high datarates to users on the surface and in Mars orbit. Twoexamples highlighting the wide variety of orbiter deliveryand configuration options were shown that could providehigh-performance service to users.

  6. Reliability of digital ulcer definitions as proposed by the UK Scleroderma Study Group: A challenge for clinical trial design.

    PubMed

    Hughes, Michael; Tracey, Andrew; Bhushan, Monica; Chakravarty, Kuntal; Denton, Christopher P; Dubey, Shirish; Guiducci, Serena; Muir, Lindsay; Ong, Voon; Parker, Louise; Pauling, John D; Prabu, Athiveeraramapandian; Rogers, Christine; Roberts, Christopher; Herrick, Ariane L

    2018-06-01

    The reliability of clinician grading of systemic sclerosis-related digital ulcers has been reported to be poor to moderate at best, which has important implications for clinical trial design. The aim of this study was to examine the reliability of new proposed UK Scleroderma Study Group digital ulcer definitions among UK clinicians with an interest in systemic sclerosis. Raters graded (through a custom-built interface) 90 images (80 unique and 10 repeat) of a range of digital lesions collected from patients with systemic sclerosis. Lesions were graded on an ordinal scale of severity: 'no ulcer', 'healed ulcer' or 'digital ulcer'. A total of 23 clinicians - 18 rheumatologists, 3 dermatologists, 1 hand surgeon and 1 specialist rheumatology nurse - completed the study. A total of 2070 (1840 unique + 230 repeat) image gradings were obtained. For intra-rater reliability, across all images, the overall weighted kappa coefficient was high (0.71) and was moderate (0.55) when averaged across individual raters. Overall inter-rater reliability was poor (0.15). Although our proposed digital ulcer definitions had high intra-rater reliability, the overall inter-rater reliability was poor. Our study highlights the challenges of digital ulcer assessment by clinicians with an interest in systemic sclerosis and provides a number of useful insights for future clinical trial design. Further research is warranted to improve the reliability of digital ulcer definition/rating as an outcome measure in clinical trials, including examining the role for objective measurement techniques, and the development of digital ulcer patient-reported outcome measures.

  7. Can real time location system technology (RTLS) provide useful estimates of time use by nursing personnel?

    PubMed

    Jones, Terry L; Schlegel, Cara

    2014-02-01

    Accurate, precise, unbiased, reliable, and cost-effective estimates of nursing time use are needed to insure safe staffing levels. Direct observation of nurses is costly, and conventional surrogate measures have limitations. To test the potential of electronic capture of time and motion through real time location systems (RTLS), a pilot study was conducted to assess efficacy (method agreement) of RTLS time use; inter-rater reliability of RTLS time-use estimates; and associated costs. Method agreement was high (mean absolute difference = 28 seconds); inter-rater reliability was high (ICC = 0.81-0.95; mean absolute difference = 2 seconds); and costs for obtaining RTLS time-use estimates on a single nursing unit exceeded $25,000. Continued experimentation with RTLS to obtain time-use estimates for nursing staff is warranted. © 2013 Wiley Periodicals, Inc.

  8. Estimating the Reliability of Electronic Parts in High Radiation Fields

    NASA Technical Reports Server (NTRS)

    Everline, Chester; Clark, Karla; Man, Guy; Rasmussen, Robert; Johnston, Allan; Kohlhase, Charles; Paulos, Todd

    2008-01-01

    Radiation effects on materials and electronic parts constrain the lifetime of flight systems visiting Europa. Understanding mission lifetime limits is critical to the design and planning of such a mission. Therefore, the operational aspects of radiation dose are a mission success issue. To predict and manage mission lifetime in a high radiation environment, system engineers need capable tools to trade radiation design choices against system design and reliability, and science achievements. Conventional tools and approaches provided past missions with conservative designs without the ability to predict their lifetime beyond the baseline mission.This paper describes a more systematic approach to understanding spacecraft design margin, allowing better prediction of spacecraft lifetime. This is possible because of newly available electronic parts radiation effects statistics and an enhanced spacecraft system reliability methodology. This new approach can be used in conjunction with traditional approaches for mission design. This paper describes the fundamentals of the new methodology.

  9. Identification of Extracellular Segments by Mass Spectrometry Improves Topology Prediction of Transmembrane Proteins.

    PubMed

    Langó, Tamás; Róna, Gergely; Hunyadi-Gulyás, Éva; Turiák, Lilla; Varga, Julia; Dobson, László; Várady, György; Drahos, László; Vértessy, Beáta G; Medzihradszky, Katalin F; Szakács, Gergely; Tusnády, Gábor E

    2017-02-13

    Transmembrane proteins play crucial role in signaling, ion transport, nutrient uptake, as well as in maintaining the dynamic equilibrium between the internal and external environment of cells. Despite their important biological functions and abundance, less than 2% of all determined structures are transmembrane proteins. Given the persisting technical difficulties associated with high resolution structure determination of transmembrane proteins, additional methods, including computational and experimental techniques remain vital in promoting our understanding of their topologies, 3D structures, functions and interactions. Here we report a method for the high-throughput determination of extracellular segments of transmembrane proteins based on the identification of surface labeled and biotin captured peptide fragments by LC/MS/MS. We show that reliable identification of extracellular protein segments increases the accuracy and reliability of existing topology prediction algorithms. Using the experimental topology data as constraints, our improved prediction tool provides accurate and reliable topology models for hundreds of human transmembrane proteins.

  10. Enabling High-Energy, High-Voltage Lithium-Ion Cells: Standardization of Coin-Cell Assembly, Electrochemical Testing, and Evaluation of Full Cells

    DOE PAGES

    Long, Brandon R.; Rinaldo, Steven G.; Gallagher, Kevin G.; ...

    2016-11-09

    Coin-cells are often the test format of choice for laboratories engaged in battery research and development as they provide a convenient platform for rapid testing of new materials on a small scale. However, reliable, reproducible data via the coin-cell format is inherently difficult, particularly in the full-cell configuration. In addition, statistical evaluation to prove the consistency and reliability of such data is often neglected. Herein we report on several studies aimed at formalizing physical process parameters and coin-cell construction related to full cells. Statistical analysis and performance benchmarking approaches are advocated as a means to more confidently track changes inmore » cell performance. Finally, we show that trends in the electrochemical data obtained from coin-cells can be reliable and informative when standardized approaches are implemented in a consistent manner.« less

  11. NASA-DoD Lead-Free Electronics Project

    NASA Technical Reports Server (NTRS)

    Kessel, Kurt

    2009-01-01

    In response to concerns about risks from lead-free induced faults to high reliability products, NASA has initiated a multi-year project to provide manufacturers and users with data to clarify the risks of lead-free materials in their products. The project will also be of interest to component manufacturers supplying to high reliability markets. The project was launched in November 2006. The primary technical objective of the project is to undertake comprehensive testing to generate information on failure modes/criteria to better understand the reliability of: (1) Packages (e.g., Thin Small Outline Package [TSOP], Ball Grid Array [BGA], Plastic Dual In-line Package [PDIP]) assembled and reworked with solder interconnects consisting of lead-free alloys (2) Packages (e.g., TSOP, BGA, PDIP) assembled and reworked with solder interconnects consisting of mixed alloys, lead component finish/lead-free solder and lead-free component finish/SnPb solder

  12. Social influences on adaptive criterion learning.

    PubMed

    Cassidy, Brittany S; Dubé, Chad; Gutchess, Angela H

    2015-07-01

    People adaptively shift decision criteria when given biased feedback encouraging specific types of errors. Given that work on this topic has been conducted in nonsocial contexts, we extended the literature by examining adaptive criterion learning in both social and nonsocial contexts. Specifically, we compared potential differences in criterion shifting given performance feedback from social sources varying in reliability and from a nonsocial source. Participants became lax when given false positive feedback for false alarms, and became conservative when given false positive feedback for misses, replicating prior work. In terms of a social influence on adaptive criterion learning, people became more lax in response style over time if feedback was provided by a nonsocial source or by a social source meant to be perceived as unreliable and low-achieving. In contrast, people adopted a more conservative response style over time if performance feedback came from a high-achieving and reliable source. Awareness that a reliable and high-achieving person had not provided their feedback reduced the tendency to become more conservative, relative to those unaware of the source manipulation. Because teaching and learning often occur in a social context, these findings may have important implications for many scenarios in which people fine-tune their behaviors, given cues from others.

  13. The inter-rater reliability test of the modified Morse Fall Scale among patients ≥ 55 years old in an acute care hospital in Singapore.

    PubMed

    Tang, Wing Sze; Chow, Yeow Leng; Koh, Serena Siew Lin

    2014-02-01

    A prospective, descriptive study was conducted in an acute care hospital in Singapore to determine the inter-rater reliability of the modified Morse Fall Scale by evaluating the degrees of agreement on the ratings of the individual items and overall score between the 'gold standard' assessor and the facility assessors. One hundred and forty-two subjects were recruited during the 1.5 month data collection period. The simple and weighted κ-values were all > 0.8 except for the item 'effects of medications' (κ and κw  = 0.63), and the correlation coefficient (rs  = 0.89) was significantly high at a significance level of < 0.001. The modified Morse Fall Scale was shown to be a reliable fall risk assessment tool having a relative high inter-rater reliability level for the overall score and individual items. This study provides evidence-based psychometric support for the clinical application of this tool. © 2013 Wiley Publishing Asia Pty Ltd.

  14. Probabilistic Structural Analysis and Reliability Using NESSUS With Implemented Material Strength Degradation Model

    NASA Technical Reports Server (NTRS)

    Bast, Callie C.; Jurena, Mark T.; Godines, Cody R.; Chamis, Christos C. (Technical Monitor)

    2001-01-01

    This project included both research and education objectives. The goal of this project was to advance innovative research and education objectives in theoretical and computational probabilistic structural analysis, reliability, and life prediction for improved reliability and safety of structural components of aerospace and aircraft propulsion systems. Research and education partners included Glenn Research Center (GRC) and Southwest Research Institute (SwRI) along with the University of Texas at San Antonio (UTSA). SwRI enhanced the NESSUS (Numerical Evaluation of Stochastic Structures Under Stress) code and provided consulting support for NESSUS-related activities at UTSA. NASA funding supported three undergraduate students, two graduate students, a summer course instructor and the Principal Investigator. Matching funds from UTSA provided for the purchase of additional equipment for the enhancement of the Advanced Interactive Computational SGI Lab established during the first year of this Partnership Award to conduct the probabilistic finite element summer courses. The research portion of this report presents the cumulation of work performed through the use of the probabilistic finite element program, NESSUS, Numerical Evaluation and Structures Under Stress, and an embedded Material Strength Degradation (MSD) model. Probabilistic structural analysis provided for quantification of uncertainties associated with the design, thus enabling increased system performance and reliability. The structure examined was a Space Shuttle Main Engine (SSME) fuel turbopump blade. The blade material analyzed was Inconel 718, since the MSD model was previously calibrated for this material. Reliability analysis encompassing the effects of high temperature and high cycle fatigue, yielded a reliability value of 0.99978 using a fully correlated random field for the blade thickness. The reliability did not change significantly for a change in distribution type except for a change in distribution from Gaussian to Weibull for the centrifugal load. The sensitivity factors determined to be most dominant were the centrifugal loading and the initial strength of the material. These two sensitivity factors were influenced most by a change in distribution type from Gaussian to Weibull. The education portion of this report describes short-term and long-term educational objectives. Such objectives serve to integrate research and education components of this project resulting in opportunities for ethnic minority students, principally Hispanic. The primary vehicle to facilitate such integration was the teaching of two probabilistic finite element method courses to undergraduate engineering students in the summers of 1998 and 1999.

  15. Sustaining Turnaround at the School and District Levels: The High Reliability Schools Project at Sandfields Secondary School

    ERIC Educational Resources Information Center

    Schaffer, Eugene; Reynolds, David; Stringfield, Sam

    2012-01-01

    Beginning from 1 high-poverty, historically low-achieving secondary school's successful turnaround work, this article provides data relative to a successful school turnaround, the importance of external and system-level supports, and the importance of building for sustainable institutionalization of improvements. The evidence suggests the…

  16. PBFA II, a 100 TW Pulsed Power Driver for the Inertial Confinement Fusion Program

    DTIC Science & Technology

    1985-06-01

    providing a 30 MV, 15 ns output pulse,which accelerates lithium ions. The ions will focus onto a pellet containing deuterium-tritium, producing fusion ... energy . Several research areas will be reviewed: low jitter, highly reliable 370 kJ Marx generators; highly synchronized gas switching at 5 MV; efficient

  17. Valid and reliable authentic assessment of culminating student performance in the biomedical sciences.

    PubMed

    Oh, Deborah M; Kim, Joshua M; Garcia, Raymond E; Krilowicz, Beverly L

    2005-06-01

    There is increasing pressure, both from institutions central to the national scientific mission and from regional and national accrediting agencies, on natural sciences faculty to move beyond course examinations as measures of student performance and to instead develop and use reliable and valid authentic assessment measures for both individual courses and for degree-granting programs. We report here on a capstone course developed by two natural sciences departments, Biological Sciences and Chemistry/Biochemistry, which engages students in an important culminating experience, requiring synthesis of skills and knowledge developed throughout the program while providing the departments with important assessment information for use in program improvement. The student work products produced in the course, a written grant proposal, and an oral summary of the proposal, provide a rich source of data regarding student performance on an authentic assessment task. The validity and reliability of the instruments and the resulting student performance data were demonstrated by collaborative review by content experts and a variety of statistical measures of interrater reliability, including percentage agreement, intraclass correlations, and generalizability coefficients. The high interrater reliability reported when the assessment instruments were used for the first time by a group of external evaluators suggests that the assessment process and instruments reported here will be easily adopted by other natural science faculty.

  18. Examining the interrater reliability of the Hare Psychopathy Checklist-Revised across a large sample of trained raters.

    PubMed

    Blais, Julie; Forth, Adelle E; Hare, Robert D

    2017-06-01

    The goal of the current study was to assess the interrater reliability of the Psychopathy Checklist-Revised (PCL-R) among a large sample of trained raters (N = 280). All raters completed PCL-R training at some point between 1989 and 2012 and subsequently provided complete coding for the same 6 practice cases. Overall, 3 major conclusions can be drawn from the results: (a) reliability of individual PCL-R items largely fell below any appropriate standards while the estimates for Total PCL-R scores and factor scores were good (but not excellent); (b) the cases representing individuals with high psychopathy scores showed better reliability than did the cases of individuals in the moderate to low PCL-R score range; and (c) there was a high degree of variability among raters; however, rater specific differences had no consistent effect on scoring the PCL-R. Therefore, despite low reliability estimates for individual items, Total scores and factor scores can be reliably scored among trained raters. We temper these conclusions by noting that scoring standardized videotaped case studies does not allow the rater to interact directly with the offender. Real-world PCL-R assessments typically involve a face-to-face interview and much more extensive collateral information. We offer recommendations for new web-based training procedures. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  19. Havens: Explicit Reliable Memory Regions for HPC Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hukerikar, Saurabh; Engelmann, Christian

    2016-01-01

    Supporting error resilience in future exascale-class supercomputing systems is a critical challenge. Due to transistor scaling trends and increasing memory density, scientific simulations are expected to experience more interruptions caused by transient errors in the system memory. Existing hardware-based detection and recovery techniques will be inadequate to manage the presence of high memory fault rates. In this paper we propose a partial memory protection scheme based on region-based memory management. We define the concept of regions called havens that provide fault protection for program objects. We provide reliability for the regions through a software-based parity protection mechanism. Our approach enablesmore » critical program objects to be placed in these havens. The fault coverage provided by our approach is application agnostic, unlike algorithm-based fault tolerance techniques.« less

  20. NREL Smart Grid Projects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hambrick, J.

    2012-01-01

    Although implementing Smart Grid projects at the distribution level provides many advantages and opportunities for advanced operation and control, a number of significant challenges must be overcome to maintain the high level of safety and reliability that the modern grid must provide. For example, while distributed generation (DG) promises to provide opportunities to increase reliability and efficiency and may provide grid support services such as volt/var control, the presence of DG can impact distribution operation and protection schemes. Additionally, the intermittent nature of many DG energy sources such as photovoltaics (PV) can present a number of challenges to voltage regulation,more » etc. This presentation provides an overview a number of Smart Grid projects being performed by the National Renewable Energy Laboratory (NREL) along with utility, industry, and academic partners. These projects include modeling and analysis of high penetration PV scenarios (with and without energy storage), development and testing of interconnection and microgrid equipment, as well as the development and implementation of advanced instrumentation and data acquisition used to analyze the impacts of intermittent renewable resources. Additionally, standards development associated with DG interconnection and analysis as well as Smart Grid interoperability will be discussed.« less

  1. Health care providers and adolescents' perspectives towards adolescents' health education needs: a need assessment based on comparative approach.

    PubMed

    Shahhosseini, Zohreh; Abedian, Kobra

    2015-02-01

    Health care providers have considerable influence on adolescents' health promotion. Thus, it is important to focus on the views of this group as one of the most reliable sources in the evaluation of teenagers' health needs. The aim of this study was to compare the attitudes of Iranian health care providers and adolescents towards the latter's health education needs. A quantitative cross-sectional survey, including 72 health care providers and 402 female students from 14 high schools in northern Iran, was carried out in 2011. Topics in a self-administrated questionnaire covered the participants' perspectives towards the educational health needs of adolescents in a five-point Likert scale. Findings revealed from health care providers' views indicate that the highest mean score was assigned to "Education about prevention of sexual high risk behavior", which was significantly different from adolescents' perspective (t=8.42, p<0.05). RESULTS showed that health care providers and adolescents both emphasized on the mothers' role as the most reliable source of adolescents' education (t=1.85, p>0.05). Provision of health education programs for adolescents, which are based on integration of health care providers' perspectives and the adolescents' views, are essential in meeting adolescents' educational health needs.

  2. Improving the reliability of inverter-based welding machines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schiedermayer, M.

    1997-02-01

    Although inverter-based welding power sources have been available since the late 1980s, many people hesitated to purchase them because of reliability issues. Unfortunately, their hesitancy had a basis, until now. Recent improvements give some inverters a reliability level that approaches that of traditional, transformer-based industrial welding machines, which have a failure rate of about 1%. Acceptance of inverter-based welding machines is important because, for many welding applications, they provide capabilities that solid-state, transformer-based machines cannot deliver. These advantages include enhanced pulsed gas metal arc welding (GMAW-P), lightweight portability, an ultrastable arc, and energy efficiency--all while producing highly aesthetic weld beadsmore » and delivering multiprocess capabilities.« less

  3. Mission Reliability Estimation for Repairable Robot Teams

    NASA Technical Reports Server (NTRS)

    Trebi-Ollennu, Ashitey; Dolan, John; Stancliff, Stephen

    2010-01-01

    A mission reliability estimation method has been designed to translate mission requirements into choices of robot modules in order to configure a multi-robot team to have high reliability at minimal cost. In order to build cost-effective robot teams for long-term missions, one must be able to compare alternative design paradigms in a principled way by comparing the reliability of different robot models and robot team configurations. Core modules have been created including: a probabilistic module with reliability-cost characteristics, a method for combining the characteristics of multiple modules to determine an overall reliability-cost characteristic, and a method for the generation of legitimate module combinations based on mission specifications and the selection of the best of the resulting combinations from a cost-reliability standpoint. The developed methodology can be used to predict the probability of a mission being completed, given information about the components used to build the robots, as well as information about the mission tasks. In the research for this innovation, sample robot missions were examined and compared to the performance of robot teams with different numbers of robots and different numbers of spare components. Data that a mission designer would need was factored in, such as whether it would be better to have a spare robot versus an equivalent number of spare parts, or if mission cost can be reduced while maintaining reliability using spares. This analytical model was applied to an example robot mission, examining the cost-reliability tradeoffs among different team configurations. Particularly scrutinized were teams using either redundancy (spare robots) or repairability (spare components). Using conservative estimates of the cost-reliability relationship, results show that it is possible to significantly reduce the cost of a robotic mission by using cheaper, lower-reliability components and providing spares. This suggests that the current design paradigm of building a minimal number of highly robust robots may not be the best way to design robots for extended missions.

  4. Scaled CMOS Technology Reliability Users Guide

    NASA Technical Reports Server (NTRS)

    White, Mark

    2010-01-01

    The desire to assess the reliability of emerging scaled microelectronics technologies through faster reliability trials and more accurate acceleration models is the precursor for further research and experimentation in this relevant field. The effect of semiconductor scaling on microelectronics product reliability is an important aspect to the high reliability application user. From the perspective of a customer or user, who in many cases must deal with very limited, if any, manufacturer's reliability data to assess the product for a highly-reliable application, product-level testing is critical in the characterization and reliability assessment of advanced nanometer semiconductor scaling effects on microelectronics reliability. A methodology on how to accomplish this and techniques for deriving the expected product-level reliability on commercial memory products are provided.Competing mechanism theory and the multiple failure mechanism model are applied to the experimental results of scaled SDRAM products. Accelerated stress testing at multiple conditions is applied at the product level of several scaled memory products to assess the performance degradation and product reliability. Acceleration models are derived for each case. For several scaled SDRAM products, retention time degradation is studied and two distinct soft error populations are observed with each technology generation: early breakdown, characterized by randomly distributed weak bits with Weibull slope (beta)=1, and a main population breakdown with an increasing failure rate. Retention time soft error rates are calculated and a multiple failure mechanism acceleration model with parameters is derived for each technology. Defect densities are calculated and reflect a decreasing trend in the percentage of random defective bits for each successive product generation. A normalized soft error failure rate of the memory data retention time in FIT/Gb and FIT/cm2 for several scaled SDRAM generations is presented revealing a power relationship. General models describing the soft error rates across scaled product generations are presented. The analysis methodology may be applied to other scaled microelectronic products and their key parameters.

  5. The specification-based validation of reliable multicast protocol: Problem Report. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Wu, Yunqing

    1995-01-01

    Reliable Multicast Protocol (RMP) is a communication protocol that provides an atomic, totally ordered, reliable multicast service on top of unreliable IP multicasting. In this report, we develop formal models for RMP using existing automated verification systems, and perform validation on the formal RMP specifications. The validation analysis help identifies some minor specification and design problems. We also use the formal models of RMP to generate a test suite for conformance testing of the implementation. Throughout the process of RMP development, we follow an iterative, interactive approach that emphasizes concurrent and parallel progress of implementation and verification processes. Through this approach, we incorporate formal techniques into our development process, promote a common understanding for the protocol, increase the reliability of our software, and maintain high fidelity between the specifications of RMP and its implementation.

  6. Material Selection for Cable Gland to Improved Reliability of the High-hazard Industries

    NASA Astrophysics Data System (ADS)

    Vashchuk, S. P.; Slobodyan, S. M.; Deeva, V. S.; Vashchuk, D. S.

    2018-01-01

    The sealed cable glands (SCG) are available to ensure safest connection sheathed single wire for the hazard production facility (nuclear power plant and others) the same as pilot cable, control cables, radio-frequency cables et al. In this paper, we investigate the specifics of the material selection of SCG with the express aim of hazardous man-made facility. We discuss the safe working conditions for cable glands. The research indicates the sintering powdered metals cables provide the reliability growth due to their properties. A number of studies have demonstrated the verification of material selection. On the face of it, we make findings indicating that double glazed sealed units could enhance reliability. We had evaluated sample reliability under fire conditions, seismic load, and pressure containment failure. We used the samples mineral insulated thermocouple cable.

  7. Incident learning in pursuit of high reliability: implementing a comprehensive, low-threshold reporting program in a large, multisite radiation oncology department.

    PubMed

    Gabriel, Peter E; Volz, Edna; Bergendahl, Howard W; Burke, Sean V; Solberg, Timothy D; Maity, Amit; Hahn, Stephen M

    2015-04-01

    Incident learning programs have been recognized as cornerstones of safety and quality assurance in so-called high reliability organizations in industries such as aviation and nuclear power. High reliability organizations are distinguished by their drive to continuously identify and proactively address a broad spectrum of latent safety issues. Many radiation oncology institutions have reported on their experience in tracking and analyzing adverse events and near misses but few have incorporated the principles of high reliability into their programs. Most programs have focused on the reporting and retrospective analysis of a relatively small number of significant adverse events and near misses. To advance a large, multisite radiation oncology department toward high reliability, a comprehensive, cost-effective, electronic condition reporting program was launched to enable the identification of a broad spectrum of latent system failures, which would then be addressed through a continuous quality improvement process. A comprehensive program, including policies, work flows, and information system, was designed and implemented, with use of a low reporting threshold to focus on precursors to adverse events. In a 46-month period from March 2011 through December 2014, a total of 8,504 conditions (average, 185 per month, 1 per patient treated, 3.9 per 100 fractions [individual treatments]) were reported. Some 77.9% of clinical staff members reported at least 1 condition. Ninety-eight percent of conditions were classified in the lowest two of four severity levels, providing the opportunity to address conditions before they contribute to adverse events. Results after approximately four years show excellent employee engagement, a sustained rate of reporting, and a focus on low-level issues leading to proactive quality improvement interventions.

  8. Reliability of high I/O high density CCGA interconnect electronic packages under extreme thermal environments

    NASA Astrophysics Data System (ADS)

    Ramesham, Rajeshuni

    2012-03-01

    Ceramic column grid array (CCGA) packages have been increasing in use based on their advantages such as high interconnect density, very good thermal and electrical performances, compatibility with standard surfacemount packaging assembly processes, and so on. CCGA packages are used in space applications such as in logic and microprocessor functions, telecommunications, payload electronics, and flight avionics. As these packages tend to have less solder joint strain relief than leaded packages or more strain relief over lead-less chip carrier packages, the reliability of CCGA packages is very important for short-term and long-term deep space missions. We have employed high density CCGA 1152 and 1272 daisy chained electronic packages in this preliminary reliability study. Each package is divided into several daisy-chained sections. The physical dimensions of CCGA1152 package is 35 mm x 35 mm with a 34 x 34 array of columns with a 1 mm pitch. The dimension of the CCGA1272 package is 37.5 mm x 37.5 mm with a 36 x 36 array with a 1 mm pitch. The columns are made up of 80% Pb/20%Sn material. CCGA interconnect electronic package printed wiring polyimide boards have been assembled and inspected using non-destructive x-ray imaging techniques. The assembled CCGA boards were subjected to extreme temperature thermal atmospheric cycling to assess their reliability for future deep space missions. The resistance of daisy-chained interconnect sections were monitored continuously during thermal cycling. This paper provides the experimental test results of advanced CCGA packages tested in extreme temperature thermal environments. Standard optical inspection and x-ray non-destructive inspection tools were used to assess the reliability of high density CCGA packages for deep space extreme temperature missions.

  9. HitPredict version 4: comprehensive reliability scoring of physical protein-protein interactions from more than 100 species.

    PubMed

    López, Yosvany; Nakai, Kenta; Patil, Ashwini

    2015-01-01

    HitPredict is a consolidated resource of experimentally identified, physical protein-protein interactions with confidence scores to indicate their reliability. The study of genes and their inter-relationships using methods such as network and pathway analysis requires high quality protein-protein interaction information. Extracting reliable interactions from most of the existing databases is challenging because they either contain only a subset of the available interactions, or a mixture of physical, genetic and predicted interactions. Automated integration of interactions is further complicated by varying levels of accuracy of database content and lack of adherence to standard formats. To address these issues, the latest version of HitPredict provides a manually curated dataset of 398 696 physical associations between 70 808 proteins from 105 species. Manual confirmation was used to resolve all issues encountered during data integration. For improved reliability assessment, this version combines a new score derived from the experimental information of the interactions with the original score based on the features of the interacting proteins. The combined interaction score performs better than either of the individual scores in HitPredict as well as the reliability score of another similar database. HitPredict provides a web interface to search proteins and visualize their interactions, and the data can be downloaded for offline analysis. Data usability has been enhanced by mapping protein identifiers across multiple reference databases. Thus, the latest version of HitPredict provides a significantly larger, more reliable and usable dataset of protein-protein interactions from several species for the study of gene groups. Database URL: http://hintdb.hgc.jp/htp. © The Author(s) 2015. Published by Oxford University Press.

  10. Definition and Proposed Realization of the International Height Reference System (IHRS)

    NASA Astrophysics Data System (ADS)

    Ihde, Johannes; Sánchez, Laura; Barzaghi, Riccardo; Drewes, Hermann; Foerste, Christoph; Gruber, Thomas; Liebsch, Gunter; Marti, Urs; Pail, Roland; Sideris, Michael

    2017-05-01

    Studying, understanding and modelling global change require geodetic reference frames with an order of accuracy higher than the magnitude of the effects to be actually studied and with high consistency and reliability worldwide. The International Association of Geodesy, taking care of providing a precise geodetic infrastructure for monitoring the Earth system, promotes the implementation of an integrated global geodetic reference frame that provides a reliable frame for consistent analysis and modelling of global phenomena and processes affecting the Earth's gravity field, the Earth's surface geometry and the Earth's rotation. The definition, realization, maintenance and wide utilization of the International Terrestrial Reference System guarantee a globally unified geometric reference frame with an accuracy at the millimetre level. An equivalent high-precision global physical reference frame that supports the reliable description of changes in the Earth's gravity field (such as sea level variations, mass displacements, processes associated with geophysical fluids) is missing. This paper addresses the theoretical foundations supporting the implementation of such a physical reference surface in terms of an International Height Reference System and provides guidance for the coming activities required for the practical and sustainable realization of this system. Based on conceptual approaches of physical geodesy, the requirements for a unified global height reference system are derived. In accordance with the practice, its realization as the International Height Reference Frame is designed. Further steps for the implementation are also proposed.

  11. Measuring cultural justifications for caregiving in African American and White caregivers.

    PubMed

    Powers, Sara M; Whitlatch, Carol J

    2016-07-01

    This report will elucidate the psychometric properties of the Cultural Justifications for Caregiving Scale (CJCS) and evaluate the differences in cultural values and demographic variables among a group of African American and White caregivers. The CJCS measures the cultural reasons for and expectations about providing care to an older relative. CJCS data were collected from 202 adults caring for an older relative with memory loss. The factor structure of the CJCS was analyzed for reliability and its correlation with other measures pertaining to the caregiving experience. Exploratory factor analyses suggested two underlying factors relating to Duty and Reciprocity with high levels of reliability. The two factors showed different correlational patterns with other measures associated with the caregiving experience (CG demographics and well-being). Findings provide further evidence that the CJCS is a reliable measure for use with African American and White caregivers. Moreover, cultural motivations to provide care may differ for ethnically diverse CGs based on religious backgrounds and beliefs about family expectations surrounding the care of loved ones. The application of the CJCS is also discussed. © The Author(s) 2014.

  12. Experimental application of OMA solutions on the model of industrial structure

    NASA Astrophysics Data System (ADS)

    Mironov, A.; Mironovs, D.

    2017-10-01

    It is very important and sometimes even vital to maintain reliability of industrial structures. High quality control during production and structural health monitoring (SHM) in exploitation provides reliable functioning of large, massive and remote structures, like wind generators, pipelines, power line posts, etc. This paper introduces a complex of technological and methodical solutions for SHM and diagnostics of industrial structures, including those that are actuated by periodic forces. Solutions were verified on a wind generator scaled model with integrated system of piezo-film deformation sensors. Simultaneous and multi-patch Operational Modal Analysis (OMA) approaches were implemented as methodical means for structural diagnostics and monitoring. Specially designed data processing algorithms provide objective evaluation of structural state modification.

  13. Characterizing ceramics and the interfacial adhesion to resin: I - The relationship of microstructure, composition, properties and fractography.

    PubMed

    Della Bona, Alvaro

    2005-03-01

    The appeal of ceramics as structural dental materials is based on their light weight, high hardness values, chemical inertness, and anticipated unique tribological characteristics. A major goal of current ceramic research and development is to produce tough, strong ceramics that can provide reliable performance in dental applications. Quantifying microstructural parameters is important to develop structure/property relationships. Quantitative microstructural analysis provides an association among the constitution, physical properties, and structural characteristics of materials. Structural reliability of dental ceramics is a major factor in the clinical success of ceramic restorations. Complex stress distributions are present in most practical conditions and strength data alone cannot be directly extrapolated to predict structural performance.

  14. Reliability and agreement in student ratings of the class environment.

    PubMed

    Nelson, Peter M; Christ, Theodore J

    2016-09-01

    The current study estimated the reliability and agreement of student ratings of the classroom environment obtained using the Responsive Environmental Assessment for Classroom Teaching (REACT; Christ, Nelson, & Demers, 2012; Nelson, Demers, & Christ, 2014). Coefficient alpha, class-level reliability, and class agreement indices were evaluated as each index provides important information for different interpretations and uses of student rating scale data. Data for 84 classes across 29 teachers in a suburban middle school were sampled to derive reliability and agreement indices for the REACT subscales across 4 class sizes: 25, 20, 15, and 10. All participating teachers were White and a larger number of 6th-grade classes were included (42%) relative to 7th- (33%) or 8th- (23%) grade classes. Teachers were responsible for a variety of content areas, including language arts (26%), science (26%), math (20%), social studies (19%), communications (6%), and Spanish (3%). Coefficient alpha estimates were generally high across all subscales and class sizes (α = .70-.95); class-mean estimates were greatly impacted by the number of students sampled from each class, with class-level reliability values generally falling below .70 when class size was reduced from 25 to 20. Further, within-class student agreement varied widely across the REACT subscales (mean agreement = .41-.80). Although coefficient alpha and test-retest reliability are commonly reported in research with student rating scales, class-level reliability and agreement are not. The observed differences across coefficient alpha, class-level reliability, and agreement indices provide evidence for evaluating students' ratings of the class environment according to their intended use (e.g., differentiating between classes, class-level instructional decisions). (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  15. Starship Life Support

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.

    2009-01-01

    The design and mass cost of a starship and its life support system are investigated. The mission plan for a multi generational interstellar voyage to colonize a new planet is used to describe the starship design, including the crew habitat, accommodations, and life support. Only current technology is assumed. Highly reliable life support systems can be provided with reasonably small additional mass, suggesting that they can support long duration missions. Bioregenerative life support, growing crop plants that provide food, water, and oxygen, has been thought to need less mass than providing stored food for long duration missions. The large initial mass of hydroponics systems is paid for over time by saving the mass of stored food. However, the yearly logistics mass required to support a bioregenerative system exceeds the mass of food solids it produces, so that supplying stored dehydrated food always requires less mass than bioregenerative food production. A mixed system that grows about half the food and supplies the other half dehydrated has advantages that allow it to breakeven with stored dehydrated food in about 66 years. However, moderate increases in the hydroponics system mass to achieve high reliability, such as adding spares that double the system mass and replacing the initial system every 100 years, increase the mass cost of bioregenerative life support. In this case, the high reliability half food growing, half food supplying system does not breakeven for 389 years. An even higher reliability half and half system, with three times original system mass and replacing the system every 50 years, never breaks even. Growing food for starship life support requires more mass than providing dehydrated food, even for multigeneration voyages of hundreds of years. The benefits of growing some food may justify the added mass cost. Much more efficient recycling food production is wanted but may not be possible. A single multigenerational interstellar voyage to colonize a new planet would have cost similar to that of the Apollo program. Cost is reduced if a small crew travels slowly and lands with minimal equipment. We can go to the stars!

  16. The Statin-Associated Muscle Symptom Clinical Index (SAMS-CI): Revision for Clinical Use, Content Validation, and Inter-rater Reliability.

    PubMed

    Rosenson, Robert S; Miller, Kate; Bayliss, Martha; Sanchez, Robert J; Baccara-Dinet, Marie T; Chibedi-De-Roche, Daniela; Taylor, Beth; Khan, Irfan; Manvelian, Garen; White, Michelle; Jacobson, Terry A

    2017-04-01

    The Statin-Associated Muscle Symptom Clinical Index (SAMS-CI) is a method for assessing the likelihood that a patient's muscle symptoms (e.g., myalgia or myopathy) were caused or worsened by statin use. The objectives of this study were to prepare the SAMS-CI for clinical use, estimate its inter-rater reliability, and collect feedback from physicians on its practical application. For content validity, we conducted structured in-depth interviews with its original authors as well as with a panel of independent physicians. Estimation of inter-rater reliability involved an analysis of 30 written clinical cases which were scored by a sample of physicians. A separate group of physicians provided feedback on the clinical use of the SAMS-CI and its potential utility in practice. Qualitative interviews with providers supported the content validity of the SAMS-CI. Feedback on the clinical use of the SAMS-CI included several perceived benefits (such as brevity, clear wording, and simple scoring process) and some possible concerns (workflow issues and applicability in primary care). The inter-rater reliability of the SAMS-CI was estimated to be 0.77 (confidence interval 0.66-0.85), indicating high concordance between raters. With additional provider feedback, a revised SAMS-CI instrument was created suitable for further testing, both in the clinical setting and in prospective validation studies. With standardized questions, vetted language, easily interpreted scores, and demonstrated reliability, the SAMS aims to estimate the likelihood that a patient's muscle symptoms were attributable to statins. The SAMS-CI may support better detection of statin-associated muscle symptoms in clinical practice, optimize treatment for patients experiencing muscle symptoms, and provide a useful tool for further clinical research.

  17. Towards Integrating Distributed Energy Resources and Storage Devices in Smart Grid.

    PubMed

    Xu, Guobin; Yu, Wei; Griffith, David; Golmie, Nada; Moulema, Paul

    2017-02-01

    Internet of Things (IoT) provides a generic infrastructure for different applications to integrate information communication techniques with physical components to achieve automatic data collection, transmission, exchange, and computation. The smart grid, as one of typical applications supported by IoT, denoted as a re-engineering and a modernization of the traditional power grid, aims to provide reliable, secure, and efficient energy transmission and distribution to consumers. How to effectively integrate distributed (renewable) energy resources and storage devices to satisfy the energy service requirements of users, while minimizing the power generation and transmission cost, remains a highly pressing challenge in the smart grid. To address this challenge and assess the effectiveness of integrating distributed energy resources and storage devices, in this paper we develop a theoretical framework to model and analyze three types of power grid systems: the power grid with only bulk energy generators, the power grid with distributed energy resources, and the power grid with both distributed energy resources and storage devices. Based on the metrics of the power cumulative cost and the service reliability to users, we formally model and analyze the impact of integrating distributed energy resources and storage devices in the power grid. We also use the concept of network calculus, which has been traditionally used for carrying out traffic engineering in computer networks, to derive the bounds of both power supply and user demand to achieve a high service reliability to users. Through an extensive performance evaluation, our data shows that integrating distributed energy resources conjointly with energy storage devices can reduce generation costs, smooth the curve of bulk power generation over time, reduce bulk power generation and power distribution losses, and provide a sustainable service reliability to users in the power grid.

  18. Towards Integrating Distributed Energy Resources and Storage Devices in Smart Grid

    PubMed Central

    Xu, Guobin; Yu, Wei; Griffith, David; Golmie, Nada; Moulema, Paul

    2017-01-01

    Internet of Things (IoT) provides a generic infrastructure for different applications to integrate information communication techniques with physical components to achieve automatic data collection, transmission, exchange, and computation. The smart grid, as one of typical applications supported by IoT, denoted as a re-engineering and a modernization of the traditional power grid, aims to provide reliable, secure, and efficient energy transmission and distribution to consumers. How to effectively integrate distributed (renewable) energy resources and storage devices to satisfy the energy service requirements of users, while minimizing the power generation and transmission cost, remains a highly pressing challenge in the smart grid. To address this challenge and assess the effectiveness of integrating distributed energy resources and storage devices, in this paper we develop a theoretical framework to model and analyze three types of power grid systems: the power grid with only bulk energy generators, the power grid with distributed energy resources, and the power grid with both distributed energy resources and storage devices. Based on the metrics of the power cumulative cost and the service reliability to users, we formally model and analyze the impact of integrating distributed energy resources and storage devices in the power grid. We also use the concept of network calculus, which has been traditionally used for carrying out traffic engineering in computer networks, to derive the bounds of both power supply and user demand to achieve a high service reliability to users. Through an extensive performance evaluation, our data shows that integrating distributed energy resources conjointly with energy storage devices can reduce generation costs, smooth the curve of bulk power generation over time, reduce bulk power generation and power distribution losses, and provide a sustainable service reliability to users in the power grid1. PMID:29354654

  19. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD

    PubMed Central

    Formiga, Magno F; Roach, Kathryn E; Vital, Isabel; Urdaneta, Gisel; Balestrini, Kira; Calderon-Candelario, Rafael A

    2018-01-01

    Purpose The Test of Incremental Respiratory Endurance (TIRE) provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP) over time. The integration of MIP over inspiratory duration (ID) provides the sustained maximal inspiratory pressure (SMIP). Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Patients and methods Test–retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. Results All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test–retest reliability with a nearly perfect intraclass correlation coefficient (ICC) of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP and ID, but not MIP. Conclusion The TIRE measures of MIP, SMIP and ID have excellent test–retest reliability and demonstrated known-groups validity in subjects with COPD. SMIP and ID also demonstrated evidence of moderate convergent validity and appear to be more stable measures in this patient population than the traditional MIP. PMID:29805255

  20. Intracranial arterial wall imaging using three-dimensional high isotropic resolution black blood MRI at 3.0 Tesla.

    PubMed

    Qiao, Ye; Steinman, David A; Qin, Qin; Etesami, Maryam; Schär, Michael; Astor, Brad C; Wasserman, Bruce A

    2011-07-01

    To develop a high isotropic-resolution sequence to evaluate intracranial vessels at 3.0 Tesla (T). Thirteen healthy volunteers and 4 patients with intracranial stenosis were imaged at 3.0T using 0.5-mm isotropic-resolution three-dimensional (3D) Volumetric ISotropic TSE Acquisition (VISTA; TSE, turbo spin echo), with conventional 2D-TSE for comparison. VISTA was repeated for 6 volunteers and 4 patients at 0.4-mm isotropic-resolution to explore the trade-off between SNR and voxel volume. Wall signal-to-noise-ratio (SNR(wall) ), wall-lumen contrast-to-noise-ratio (CNR(wall-lumen) ), lumen area (LA), wall area (WA), mean wall thickness (MWT), and maximum wall thickness (maxWT) were compared between 3D-VISTA and 2D-TSE sequences, as well as 3D images acquired at both resolutions. Reliability was assessed by intraclass correlations (ICC). Compared with 2D-TSE measurements, 3D-VISTA provided 58% and 74% improvement in SNR(wall) and CNR(wall-lumen) , respectively. LA, WA, MWT and maxWT from 3D and 2D techniques highly correlated (ICCs of 0.96, 0.95, 0.96, and 0.91, respectively). CNR(wall-lumen) using 0.4-mm resolution VISTA decreased by 27%, compared with 0.5-mm VISTA but with reduced partial-volume-based overestimation of wall thickness. Reliability for 3D measurements was good to excellent. The 3D-VISTA provides SNR-efficient, highly reliable measurements of intracranial vessels at high isotropic-resolution, enabling broad coverage in a clinically acceptable time. Copyright © 2011 Wiley-Liss, Inc.

  1. Online registration of monthly sports participation after anterior cruciate ligament injury: a reliability and validity study

    PubMed Central

    Grindem, Hege; Eitzen, Ingrid; Snyder-Mackler, Lynn; Risberg, May Arna

    2013-01-01

    Background Current methods measuring sports activity after anterior cruciate ligament (ACL) injury are commonly restricted to the most knee-demanding sport, and do not consider participation in multiple sports. We therefore developed an online activity survey to prospectively record monthly participation in all major sports relevant to our patient-group. Objective To assess the reliability, content validity, and concurrent validity of the survey, and evaluate if it provided more complete data on sports participation than a routine activity questionnaire. Methods One hundred and forty-five consecutively included ACL-injured patients were eligible for the reliability study. The retest of the online activity survey was performed two days after the test response had been recorded. A subsample of 88 ACL-reconstructed patients were included in the validity study. The ACL-reconstructed patients completed the online activity survey from the first to the twelfth postoperative month, and a routine activity questionnaire 6 and 12 months postoperatively. Results The online activity survey was highly reliable (κ ranging from 0.81 to 1). It contained all the common sports reported on the routine activity questionnaire. There was substantial agreement between the two methods on return to preinjury main sport (κ = 0.71 and 0.74 at 6 and 12 months postoperatively). The online activity survey revealed that a significantly higher number of patients reported to participate in running, cycling and strength training, and patients reported to participate in a greater number of sports. Conclusion The online activity survey is a highly reliable way of recording detailed changes in sports participation after ACL injury. The findings of this study support the content and concurrent validity of the survey, and suggest that the online activity survey can provide more complete data on sports participation than a routine activity questionnaire. PMID:23645830

  2. Online registration of monthly sports participation after anterior cruciate ligament injury: a reliability and validity study.

    PubMed

    Grindem, Hege; Eitzen, Ingrid; Snyder-Mackler, Lynn; Risberg, May Arna

    2014-05-01

    The current methods measuring sports activity after anterior cruciate ligament (ACL) injury are commonly restricted to the most knee-demanding sports, and do not consider participation in multiple sports. We therefore developed an online activity survey to prospectively record the monthly participation in all major sports relevant to our patient-group. To assess the reliability, content validity and concurrent validity of the survey and to evaluate if it provided more complete data on sports participation than a routine activity questionnaire. 145 consecutively included ACL-injured patients were eligible for the reliability study. The retest of the online activity survey was performed 2 days after the test response had been recorded. A subsample of 88 ACL-reconstructed patients was included in the validity study. The ACL-reconstructed patients completed the online activity survey from the first to the 12th postoperative month, and a routine activity questionnaire 6 and 12 months postoperatively. The online activity survey was highly reliable (κ ranging from 0.81 to 1). It contained all the common sports reported on the routine activity questionnaire. There was a substantial agreement between the two methods on return to preinjury main sport (κ=0.71 and 0.74 at 6 and 12 months postoperatively). The online activity survey revealed that a significantly higher number of patients reported to participate in running, cycling and strength training, and patients reported to participate in a greater number of sports. The online activity survey is a highly reliable way of recording detailed changes in sports participation after ACL injury. The findings of this study support the content and concurrent validity of the survey, and suggest that the online activity survey can provide more complete data on sports participation than a routine activity questionnaire.

  3. Can Touch Screen Tablets be Used to Assess Cognitive and Motor Skills in Early Years Primary School Children? A Cross-Cultural Study.

    PubMed

    Pitchford, Nicola J; Outhwaite, Laura A

    2016-01-01

    Assessment of cognitive and motor functions is fundamental for developmental and neuropsychological profiling. Assessments are usually conducted on an individual basis, with a trained examiner, using standardized paper and pencil tests, and can take up to an hour or more to complete, depending on the nature of the test. This makes traditional standardized assessments of child development largely unsuitable for use in low-income countries. Touch screen tablets afford the opportunity to assess cognitive functions in groups of participants, with untrained administrators, with precision recording of responses, thus automating the assessment process. In turn, this enables cognitive profiling to be conducted in contexts where access to qualified examiners and standardized assessments are rarely available. As such, touch screen assessments could provide a means of assessing child development in both low- and high-income countries, which would afford cross-cultural comparisons to be made with the same assessment tool. However, before touch screen tablet assessments can be used for cognitive profiling in low-to-high-income countries they need to be shown to provide reliable and valid measures of performance. We report the development of a new touch screen tablet assessment of basic cognitive and motor functions for use with early years primary school children in low- and high-income countries. Measures of spatial intelligence, visual attention, short-term memory, working memory, manual processing speed, and manual coordination are included as well as mathematical knowledge. To investigate if this new touch screen assessment tool can be used for cross-cultural comparisons we administered it to a sample of children ( N = 283) spanning standards 1-3 in a low-income country, Malawi, and a smaller sample of children ( N = 70) from first year of formal schooling from a high-income country, the UK. Split-half reliability, test-retest reliability, face validity, convergent construct validity, predictive criterion validity, and concurrent criterion validity were investigated. Results demonstrate "proof of concept" that touch screen tablet technology can provide reliable and valid psychometric measures of performance in the early years, highlighting its potential to be used in cross-cultural comparisons and research.

  4. Validation of the one pass measure for motivational interviewing competence.

    PubMed

    McMaster, Fiona; Resnicow, Ken

    2015-04-01

    This paper examines the psychometric properties of the OnePass coding system: a new, user-friendly tool for evaluating practitioner competence in motivational interviewing (MI). We provide data on reliability and validity with the current gold-standard: Motivational Interviewing Treatment Integrity tool (MITI). We compared scores from 27 videotaped MI sessions performed by student counselors trained in MI and simulated patients using both OnePass and MITI, with three different raters for each tool. Reliability was estimated using intra-class coefficients (ICCs), and validity was assessed using Pearson's r. OnePass had high levels of inter-rater reliability with 19/23 items found from substantial to almost perfect agreement. Taking the pair of scores with the highest inter-rater reliability on the MITI, the concurrent validity between the two measures ranged from moderate to high. Validity was highest for evocation, autonomy, direction and empathy. OnePass appears to have good inter-rater reliability while capturing similar dimensions of MI as the MITI. Despite the moderate concurrent validity with the MITI, the OnePass shows promise in evaluating both traditional and novel interpretations of MI. OnePass may be a useful tool for developing and improving practitioner competence in MI where access to MITI coders is limited. Copyright © 2015. Published by Elsevier Ireland Ltd.

  5. On the Simulation-Based Reliability of Complex Emergency Logistics Networks in Post-Accident Rescues.

    PubMed

    Wang, Wei; Huang, Li; Liang, Xuedong

    2018-01-06

    This paper investigates the reliability of complex emergency logistics networks, as reliability is crucial to reducing environmental and public health losses in post-accident emergency rescues. Such networks' statistical characteristics are analyzed first. After the connected reliability and evaluation indices for complex emergency logistics networks are effectively defined, simulation analyses of network reliability are conducted under two different attack modes using a particular emergency logistics network as an example. The simulation analyses obtain the varying trends in emergency supply times and the ratio of effective nodes and validates the effects of network characteristics and different types of attacks on network reliability. The results demonstrate that this emergency logistics network is both a small-world and a scale-free network. When facing random attacks, the emergency logistics network steadily changes, whereas it is very fragile when facing selective attacks. Therefore, special attention should be paid to the protection of supply nodes and nodes with high connectivity. The simulation method provides a new tool for studying emergency logistics networks and a reference for similar studies.

  6. On the Simulation-Based Reliability of Complex Emergency Logistics Networks in Post-Accident Rescues

    PubMed Central

    Wang, Wei; Huang, Li; Liang, Xuedong

    2018-01-01

    This paper investigates the reliability of complex emergency logistics networks, as reliability is crucial to reducing environmental and public health losses in post-accident emergency rescues. Such networks’ statistical characteristics are analyzed first. After the connected reliability and evaluation indices for complex emergency logistics networks are effectively defined, simulation analyses of network reliability are conducted under two different attack modes using a particular emergency logistics network as an example. The simulation analyses obtain the varying trends in emergency supply times and the ratio of effective nodes and validates the effects of network characteristics and different types of attacks on network reliability. The results demonstrate that this emergency logistics network is both a small-world and a scale-free network. When facing random attacks, the emergency logistics network steadily changes, whereas it is very fragile when facing selective attacks. Therefore, special attention should be paid to the protection of supply nodes and nodes with high connectivity. The simulation method provides a new tool for studying emergency logistics networks and a reference for similar studies. PMID:29316614

  7. ERP Reliability Analysis (ERA) Toolbox: An open-source toolbox for analyzing the reliability of event-related brain potentials.

    PubMed

    Clayson, Peter E; Miller, Gregory A

    2017-01-01

    Generalizability theory (G theory) provides a flexible, multifaceted approach to estimating score reliability. G theory's approach to estimating score reliability has important advantages over classical test theory that are relevant for research using event-related brain potentials (ERPs). For example, G theory does not require parallel forms (i.e., equal means, variances, and covariances), can handle unbalanced designs, and provides a single reliability estimate for designs with multiple sources of error. This monograph provides a detailed description of the conceptual framework of G theory using examples relevant to ERP researchers, presents the algorithms needed to estimate ERP score reliability, and provides a detailed walkthrough of newly-developed software, the ERP Reliability Analysis (ERA) Toolbox, that calculates score reliability using G theory. The ERA Toolbox is open-source, Matlab software that uses G theory to estimate the contribution of the number of trials retained for averaging, group, and/or event types on ERP score reliability. The toolbox facilitates the rigorous evaluation of psychometric properties of ERP scores recommended elsewhere in this special issue. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. System reliability, performance and trust in adaptable automation.

    PubMed

    Chavaillaz, Alain; Wastell, David; Sauer, Jürgen

    2016-01-01

    The present study examined the effects of reduced system reliability on operator performance and automation management in an adaptable automation environment. 39 operators were randomly assigned to one of three experimental groups: low (60%), medium (80%), and high (100%) reliability of automation support. The support system provided five incremental levels of automation which operators could freely select according to their needs. After 3 h of training on a simulated process control task (AutoCAMS) in which the automation worked infallibly, operator performance and automation management were measured during a 2.5-h testing session. Trust and workload were also assessed through questionnaires. Results showed that although reduced system reliability resulted in lower levels of trust towards automation, there were no corresponding differences in the operators' reliance on automation. While operators showed overall a noteworthy ability to cope with automation failure, there were, however, decrements in diagnostic speed and prospective memory with lower reliability. Copyright © 2015. Published by Elsevier Ltd.

  9. Modeling Electricity Sector Vulnerabilities and Costs Associated with Water Temperatures Under Scenarios of Climate Change

    NASA Astrophysics Data System (ADS)

    Macknick, J.; Miara, A.; Brinkman, G.; Ibanez, E.; Newmark, R. L.

    2014-12-01

    The reliability of the power sector is highly vulnerable to variability in the availability and temperature of water resources, including those that might result from potential climatic changes or from competition from other users. In the past decade, power plants throughout the United States have had to shut down or curtail generation due to a lack of available water or from elevated water temperatures. These disruptions in power plant performance can have negative impacts on energy security and can be costly to address. Analysis of water-related vulnerabilities requires modeling capabilities with high spatial and temporal resolution. This research provides an innovative approach to energy-water modeling by evaluating the costs and reliability of a power sector region under policy and climate change scenarios that affect water resource availability and temperatures. This work utilizes results from a spatially distributed river water temperature model coupled with a thermoelectric power plant model to provide inputs into an electricity production cost model that operates on a high spatial and temporal resolution. The regional transmission organization ISO-New England, which includes six New England states and over 32 Gigawatts of power capacity, is utilized as a case study. Hydrological data and power plant operations are analyzed over an eleven year period from 2000-2010 under four scenarios that include climate impacts on water resources and air temperatures as well as strict interpretations of regulations that can affect power plant operations due to elevated water temperatures. Results of these model linkages show how the power sector's reliability and economic performance can be affected by changes in water temperatures and water availability. The effective reliability and capacity value of thermal electric generators are quantified and discussed in the context of current as well as potential future water resource characteristics.

  10. Reliability prediction of large fuel cell stack based on structure stress analysis

    NASA Astrophysics Data System (ADS)

    Liu, L. F.; Liu, B.; Wu, C. W.

    2017-09-01

    The aim of this paper is to improve the reliability of Proton Electrolyte Membrane Fuel Cell (PEMFC) stack by designing the clamping force and the thickness difference between the membrane electrode assembly (MEA) and the gasket. The stack reliability is directly determined by the component reliability, which is affected by the material property and contact stress. The component contact stress is a random variable because it is usually affected by many uncertain factors in the production and clamping process. We have investigated the influences of parameter variation coefficient on the probability distribution of contact stress using the equivalent stiffness model and the first-order second moment method. The optimal contact stress to make the component stay in the highest level reliability is obtained by the stress-strength interference model. To obtain the optimal contact stress between the contact components, the optimal thickness of the component and the stack clamping force are optimally designed. Finally, a detailed description is given how to design the MEA and gasket dimensions to obtain the highest stack reliability. This work can provide a valuable guidance in the design of stack structure for a high reliability of fuel cell stack.

  11. Intrarater Reliability of Muscle Strength and Hamstring to Quadriceps Strength Imbalance Ratios During Concentric, Isometric, and Eccentric Maximal Voluntary Contractions Using the Isoforce Dynamometer.

    PubMed

    Mau-Moeller, Anett; Gube, Martin; Felser, Sabine; Feldhege, Frank; Weippert, Matthias; Husmann, Florian; Tischer, Thomas; Bader, Rainer; Bruhn, Sven; Behrens, Martin

    2017-08-17

    To determine intrasession and intersession reliability of strength measurements and hamstrings to quadriceps strength imbalance ratios (H/Q ratios) using the new isoforce dynamometer. Repeated measures. Exercise science laboratory. Thirty healthy subjects (15 females, 15 males, 27.8 years). Coefficient of variation (CV) and intraclass correlation coefficients (ICC) were calculated for (1) strength parameters, that is peak torque, mean work, and mean power for concentric and eccentric maximal voluntary contractions; isometric maximal voluntary torque (IMVT); rate of torque development (RTD), and (2) H/Q ratios, that is conventional concentric, eccentric, and isometric H/Q ratios (Hcon/Qcon at 60 deg/s, 120 deg/s, and 180 deg/s, Hecc/Qecc at -60 deg/s and Hiso/Qiso) and functional eccentric antagonist to concentric agonist H/Q ratios (Hecc/Qcon and Hcon/Qecc). High reliability: CV <10%, ICC >0.90; moderate reliability: CV between 10% and 20%, ICC between 0.80 and 0.90; low reliability: CV >20%, ICC <0.80. (1) Strength parameters: (a) high intrasession reliability for concentric, eccentric, and isometric measurements, (b) moderate-to-high intersession reliability for concentric and eccentric measurements and IMVT, and (c) moderate-to-high intrasession reliability but low intersession reliability for RTD. (2) H/Q ratios: (a) moderate-to-high intrasession reliability for conventional ratios, (b) high intrasession reliability for functional ratios, (c) higher intersession reliability for Hcon/Qcon and Hiso/Qiso (moderate to high) than Hecc/Qecc (low to moderate), and (d) higher intersession reliability for conventional H/Q ratios (low to high) than functional H/Q ratios (low to moderate). The results have confirmed the reliability of strength parameters and the most frequently used H/Q ratios.

  12. Consistency of clinical biomechanical measures between three different institutions: implications for multi-center biomechanical and epidemiological research.

    PubMed

    Myer, Gregory D; Wordeman, Samuel C; Sugimoto, Dai; Bates, Nathaniel A; Roewer, Benjamin D; Medina McKeon, Jennifer M; DiCesare, Christopher A; Di Stasi, Stephanie L; Barber Foss, Kim D; Thomas, Staci M; Hewett, Timothy E

    2014-05-01

    Multi-center collaborations provide a powerful alternative to overcome the inherent limitations to single-center investigations. Specifically, multi-center projects can support large-scale prospective, longitudinal studies that investigate relatively uncommon outcomes, such as anterior cruciate ligament injury. This project was conceived to assess within- and between-center reliability of an affordable, clinical nomogram utilizing two-dimensional video methods to screen for risk of knee injury. The authors hypothesized that the two-dimensional screening methods would provide good-to-excellent reliability within and between institutions for assessment of frontal and sagittal plane biomechanics. Nineteen female, high school athletes participated. Two-dimensional video kinematics of the lower extremity during a drop vertical jump task were collected on all 19 study participants at each of the three facilities. Within-center and between-center reliability were assessed with intra- and inter-class correlation coefficients. Within-center reliability of the clinical nomogram variables was consistently excellent, but between-center reliability was fair-to-good. Within-center intra-class correlation coefficient for all nomogram variables combined was 0.98, while combined between-center inter-class correlation coefficient was 0.63. Injury risk screening protocols were reliable within and repeatable between centers. These results demonstrate the feasibility of multi-site biomechanical studies and establish a framework for further dissemination of injury risk screening algorithms. Specifically, multi-center studies may allow for further validation and optimization of two-dimensional video screening tools. 2b.

  13. Blinded evaluation of interrater reliability of an operative competency assessment tool for direct laryngoscopy and rigid bronchoscopy.

    PubMed

    Ishman, Stacey L; Benke, James R; Johnson, Kaalan Erik; Zur, Karen B; Jacobs, Ian N; Thorne, Marc C; Brown, David J; Lin, Sandra Y; Bhatti, Nasir; Deutsch, Ellen S

    2012-10-01

    OBJECTIVES To confirm interrater reliability using blinded evaluation of a skills-assessment instrument to assess the surgical performance of resident and fellow trainees performing pediatric direct laryngoscopy and rigid bronchoscopy in simulated models. DESIGN Prospective, paired, blinded observational validation study. SUBJECTS Paired observers from multiple institutions simultaneously evaluated residents and fellows who were performing surgery in an animal laboratory or using high-fidelity manikins. The evaluators had no previous affiliation with the residents and fellows and did not know their year of training. INTERVENTIONS One- and 2-page versions of an objective structured assessment of technical skills (OSATS) assessment instrument composed of global and a task-specific surgical items were used to evaluate surgical performance. RESULTS Fifty-two evaluations were completed by 17 attending evaluators. The instrument agreement for the 2-page assessment was 71.4% when measured as a binary variable (ie, competent vs not competent) (κ = 0.38; P = .08). Evaluation as a continuous variable revealed a 42.9% percentage agreement (κ = 0.18; P = .14). The intraclass correlation was 0.53, considered substantial/good interrater reliability (69% reliable). For the 1-page instrument, agreement was 77.4% when measured as a binary variable (κ = 0.53, P = .0015). Agreement when evaluated as a continuous measure was 71.0% (κ = 0.54, P < .001). The intraclass correlation was 0.73, considered high interrater reliability (85% reliable). CONCLUSIONS The OSATS assessment instrument is an effective tool for evaluating surgical performance among trainees with acceptable interrater reliability in a simulator setting. Reliability was good for both the 1- and 2-page OSATS checklists, and both serve as excellent tools to provide immediate formative feedback on operational competency.

  14. High-Speed Data Recorder for Space, Geodesy, and Other High-Speed Recording Applications

    NASA Technical Reports Server (NTRS)

    Taveniku, Mikael

    2013-01-01

    A high-speed data recorder and replay equipment has been developed for reliable high-data-rate recording to disk media. It solves problems with slow or faulty disks, multiple disk insertions, high-altitude operation, reliable performance using COTS hardware, and long-term maintenance and upgrade path challenges. The current generation data recor - ders used within the VLBI community are aging, special-purpose machines that are both slow (do not meet today's requirements) and are very expensive to maintain and operate. Furthermore, they are not easily upgraded to take advantage of commercial technology development, and are not scalable to multiple 10s of Gbit/s data rates required by new applications. The innovation provides a softwaredefined, high-speed data recorder that is scalable with technology advances in the commercial space. It maximally utilizes current technologies without being locked to a particular hardware platform. The innovation also provides a cost-effective way of streaming large amounts of data from sensors to disk, enabling many applications to store raw sensor data and perform post and signal processing offline. This recording system will be applicable to many applications needing realworld, high-speed data collection, including electronic warfare, softwaredefined radar, signal history storage of multispectral sensors, development of autonomous vehicles, and more.

  15. Space propulsion

    NASA Astrophysics Data System (ADS)

    Kazaroff, John M.

    1993-02-01

    Lewis Research Center is developing broad-based new technologies for space chemical engines to satisfy long-term needs of ETO launch vehicles and other vehicles operating in and beyond Earth orbit. Specific objectives are focused on high performance LO2/LH2 engines providing moderate thrusts of 7,5-200 klb. This effort encompasses research related to design analysis and manufacturing processes needed to apply advanced materials to subcomponents, components, and subsystems of space-based systems and related ground-support equipment. High-performance space-based chemical engines face a number of technical challenges. Liquid hydrogen turbopump impellers are often so large that they cannot be machined from a single piece, yet high stress at the vane/shroud interface makes bonding extremely difficult. Tolerances on fillets are critical on large impellers. Advanced materials and fabricating techniques are needed to address these and other issues of interest. Turbopump bearings are needed which can provide reliable, long life operation at high speed and high load with low friction losses. Hydrostatic bearings provide good performance, but transients during pump starts and stops may be an issue because no pressurized fluid is available unless a separate bearing pressurization system is included. Durable materials and/or coatings are needed that can demonstrate low wear in the harsh LO2/LH2 environment. Advanced materials are also needed to improve the lifetime, reliability and performance of other propulsion system elements such as seals and chambers.

  16. Measuring patient-provider communication skills in Rwanda: Selection, adaptation and assessment of psychometric properties of the Communication Assessment Tool.

    PubMed

    Cubaka, Vincent Kalumire; Schriver, Michael; Vedsted, Peter; Makoul, Gregory; Kallestrup, Per

    2018-04-23

    To identify, adapt and validate a measure for providers' communication and interpersonal skills in Rwanda. After selection, translation and piloting of the measure, structural validity, test-retest reliability, and differential item functioning were assessed. Identification and adaptation: The 14-item Communication Assessment Tool (CAT) was selected and adapted. Content validation found all items highly relevant in the local context except two, which were retained upon understanding the reasoning applied by patients. Eleven providers and 291 patients were involved in the field-testing. Confirmatory factor analysis showed a good fit for the original one factor model. Test-retest reliability assessment revealed a mean quadratic weighted Kappa = 0.81 (range: 0.69-0.89, N = 57). The average proportion of excellent scores was 15.7% (SD: 24.7, range: 9.9-21.8%, N = 180). Differential item functioning was not observed except for item 1, which focuses on greetings, for age groups (p = 0.02, N = 180). The Kinyarwanda version of CAT (K-CAT) is a reliable and valid patient-reported measure of providers' communication and interpersonal skills. K-CAT was validated on nurses and its use on other types of providers may require further validation. K-CAT is expected to be a valuable feedback tool for providers in practice and in training. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. A case of the birth and death of a high reliability healthcare organisation.

    PubMed

    Roberts, K H; Madsen, P; Desai, V; Van Stralen, D

    2005-06-01

    High reliability organisations (HROs) are those in which errors rarely occur. To accomplish this they conduct relatively error free operations over long periods of time and make consistently good decisions resulting in high quality and reliability. Some organisational processes that characterise HROs are process auditing, implementing appropriate reward systems, avoiding quality degradation, appropriately perceiving that risk exists and developing strategies to deal with it, and command and control. Command and control processes include migrating decision making, redundancy in people or hardware, developing situational awareness, formal rules and procedures, and training. These processes must be tailored to the specific organisation implementing them. These processes were applied to a paediatric intensive care unit (PICU) where care was derived from problem solving methodology rather than protocol. After a leadership change, the unit returned to the hierarchical medical model of care. Important outcome variables such as infant mortality, patient return to the PICU after discharge, days on the PICU, air transports, degraded. Implications for clinical practice include providing caregivers with sufficient flexibility to meet changing situations, encouraging teamwork, and avoiding shaming, naming, and blaming.

  18. Using the Reliability Theory for Assessing the Decision Confidence Probability for Comparative Life Cycle Assessments.

    PubMed

    Wei, Wei; Larrey-Lassalle, Pyrène; Faure, Thierry; Dumoulin, Nicolas; Roux, Philippe; Mathias, Jean-Denis

    2016-03-01

    Comparative decision making process is widely used to identify which option (system, product, service, etc.) has smaller environmental footprints and for providing recommendations that help stakeholders take future decisions. However, the uncertainty problem complicates the comparison and the decision making. Probability-based decision support in LCA is a way to help stakeholders in their decision-making process. It calculates the decision confidence probability which expresses the probability of a option to have a smaller environmental impact than the one of another option. Here we apply the reliability theory to approximate the decision confidence probability. We compare the traditional Monte Carlo method with a reliability method called FORM method. The Monte Carlo method needs high computational time to calculate the decision confidence probability. The FORM method enables us to approximate the decision confidence probability with fewer simulations than the Monte Carlo method by approximating the response surface. Moreover, the FORM method calculates the associated importance factors that correspond to a sensitivity analysis in relation to the probability. The importance factors allow stakeholders to determine which factors influence their decision. Our results clearly show that the reliability method provides additional useful information to stakeholders as well as it reduces the computational time.

  19. Reliability Analysis of Brittle Material Structures - Including MEMS(?) - With the CARES/Life Program

    NASA Technical Reports Server (NTRS)

    Nemeth, Noel N.

    2002-01-01

    Brittle materials are being used, or considered, for a wide variety of high tech applications that operate in harsh environments, including static and rotating turbine parts. thermal protection systems, dental prosthetics, fuel cells, oxygen transport membranes, radomes, and MEMS. Designing components to sustain repeated load without fracturing while using the minimum amount of material requires the use of a probabilistic design methodology. The CARES/Life code provides a general-purpose analysis tool that predicts the probability of failure of a ceramic component as a function of its time in service. For this presentation an interview of the CARES/Life program will be provided. Emphasis will be placed on describing the latest enhancements to the code for reliability analysis with time varying loads and temperatures (fully transient reliability analysis). Also, early efforts in investigating the validity of using Weibull statistics, the basis of the CARES/Life program, to characterize the strength of MEMS structures will be described as as well as the version of CARES/Life for MEMS (CARES/MEMS) being prepared which incorporates single crystal and edge flaw reliability analysis capability. It is hoped this talk will open a dialog for potential collaboration in the area of MEMS testing and life prediction.

  20. Integrated material state awareness system with self-learning symbiotic diagnostic algorithms and models

    NASA Astrophysics Data System (ADS)

    Banerjee, Sourav; Liu, Lie; Liu, S. T.; Yuan, Fuh-Gwo; Beard, Shawn

    2011-04-01

    Materials State Awareness (MSA) goes beyond traditional NDE and SHM in its challenge to characterize the current state of material damage before the onset of macro-damage such as cracks. A highly reliable, minimally invasive system for MSA of Aerospace Structures, Naval structures as well as next generation space systems is critically needed. Development of such a system will require a reliable SHM system that can detect the onset of damage well before the flaw grows to a critical size. Therefore, it is important to develop an integrated SHM system that not only detects macroscale damages in the structures but also provides an early indication of flaw precursors and microdamages. The early warning for flaw precursors and their evolution provided by an SHM system can then be used to define remedial strategies before the structural damage leads to failure, and significantly improve the safety and reliability of the structures. Thus, in this article a preliminary concept of developing the Hybrid Distributed Sensor Network Integrated with Self-learning Symbiotic Diagnostic Algorithms and Models to accurately and reliably detect the precursors to damages that occur to the structure are discussed. Experiments conducted in a laboratory environment shows potential of the proposed technique.

  1. Preliminary design of the redundant software experiment

    NASA Technical Reports Server (NTRS)

    Campbell, Roy; Deimel, Lionel; Eckhardt, Dave, Jr.; Kelly, John; Knight, John; Lauterbach, Linda; Lee, Larry; Mcallister, Dave; Mchugh, John

    1985-01-01

    The goal of the present experiment is to characterize the fault distributions of highly reliable software replicates, constructed using techniques and environments which are similar to those used in comtemporary industrial software facilities. The fault distributions and their effect on the reliability of fault tolerant configurations of the software will be determined through extensive life testing of the replicates against carefully constructed randomly generated test data. Each detected error will be carefully analyzed to provide insight in to their nature and cause. A direct objective is to develop techniques for reducing the intensity of coincident errors, thus increasing the reliability gain which can be achieved with fault tolerance. Data on the reliability gains realized, and the cost of the fault tolerant configurations can be used to design a companion experiment to determine the cost effectiveness of the fault tolerant strategy. Finally, the data and analysis produced by this experiment will be valuable to the software engineering community as a whole because it will provide a useful insight into the nature and cause of hard to find, subtle faults which escape standard software engineering validation techniques and thus persist far into the software life cycle.

  2. Determination of Aspartame, Caffeine, Saccharin, and Benzoic Acid in Beverages by High Performance Liquid Chromatography.

    ERIC Educational Resources Information Center

    Delaney, Michael F.; And Others

    1985-01-01

    Describes a simple and reliable new quantitative analysis experiment using liquid chromatography for the determinaiton of caffeine, saccharin, and sodium benzoate in beverages. Background information, procedures used, and typical results obtained are provided. (JN)

  3. Rendezvous strategy impacts on CTV avionics design, system reliability requirements, and available collision avoidance maneuvers

    NASA Technical Reports Server (NTRS)

    Donovan, William J.; Davis, John E.

    1991-01-01

    Rockwell International is conducting an ongoing program to develop avionics architectures that provide high intrinsic value while meeting all mission objectives. Studies are being conducted to determine alternative configurations that have low life-cycle cost and minimum development risk, and that minimize launch delays while providing the reliability level to assure a successful mission. This effort is based on four decades of providing ballistic missile avionics to the United States Air Force and has focused on the requirements of the NASA Cargo Transfer Vehicle (CTV) program in 1991. During the development of architectural concepts it became apparent that rendezvous strategy issues have an impact on the architecture of the avionics system. This is in addition to the expected impact on propulsion and electrical power duration, flight profiles, and trajectory during approach.

  4. High reliability and implications for nursing leaders.

    PubMed

    Riley, William

    2009-03-01

    To review high reliability theory and discuss its implications for the nursing leader. A high reliability organization (HRO) is considered that which has measurable near perfect performance for quality and safety. The author has reviewed the literature, discussed research findings that contribute to improving reliability in health care organizations, and makes five recommendations for how nursing leaders can create high reliability organizations. Health care is not a safe industry and unintended patient harm occurs at epidemic levels. Health care can learn from high reliability theory and practice developed in other high-risk industries. Viewed by HRO standards, unintended patient injury in health care is excessively high and quality is distressingly low. HRO theory and practice can be successfully applied in health care using advanced interdisciplinary teamwork training and deliberate process design techniques. Nursing has a primary leadership function for ensuring patient safety and achieving high quality in health care organizations. Learning HRO theory and methods for achieving high reliability is a foremost opportunity for nursing leaders.

  5. The 20 GHz solid state transmitter design, impatt diode development and reliability assessment

    NASA Technical Reports Server (NTRS)

    Picone, S.; Cho, Y.; Asmus, J. R.

    1984-01-01

    A single drift gallium arsenide (GaAs) Schottky barrier IMPATT diode and related components were developed. The IMPATT diode reliability was assessed. A proof of concept solid state transmitter design and a technology assessment study were performed. The transmitter design utilizes technology which, upon implementation, will demonstrate readiness for development of a POC model within the 1982 time frame and will provide an information base for flight hardware capable of deployment in a 1985 to 1990 demonstrational 30/20 GHz satellite communication system. Life test data for Schottky barrier GaAs diodes and grown junction GaAs diodes are described. The results demonstrate the viability of GaAs IMPATTs as high performance, reliable RF power sources which, based on the recommendation made herein, will surpass device reliability requirements consistent with a ten year spaceborne solid state power amplifier mission.

  6. Reproducibility of African giant pouched rats detecting Mycobacterium tuberculosis.

    PubMed

    Ellis, Haylee; Mulder, Christiaan; Valverde, Emilio; Poling, Alan; Edwards, Timothy

    2017-04-24

    African pouched rats sniffing sputum samples provided by local clinics have significantly increased tuberculosis case findings in Tanzania and Mozambique. The objective of this study was to determine the reproducibility of rat results. Over an 18-month period 11,869 samples were examined by the rats. Intra-rater reliability was assessed through Yule's Q. Inter-rater reliability was assessed with Krippendorff's alpha. Intra-rater reliability was high, with a mean Yule's Q of 0.9. Inter-rater agreement was fair, with Krippendorf's alpha ranging from 0.15 to 0.45. Both Intra- and Inter-rater reliability was independent of the sex of the animals, but they were positively correlated with age. Both intra- and inter-rater agreement was lowest for samples designated as smear-negative by the clinics. Overall, the reproducibility of tuberculosis detection rat results was fair and diagnostic results were therefore independent of the rats used.

  7. Confirmatory Factor Analysis of the System for Evaluation of Teaching Qualities (SETQ) in Graduate Medical Training.

    PubMed

    Boerebach, Benjamin C M; Lombarts, Kiki M J M H; Arah, Onyebuchi A

    2016-03-01

    The System for Evaluation of Teaching Qualities (SETQ) was developed as a formative system for the continuous evaluation and development of physicians' teaching performance in graduate medical training. It has been seven years since the introduction and initial exploratory psychometric analysis of the SETQ questionnaires. This study investigates the validity and reliability of the SETQ questionnaires across hospitals and medical specialties using confirmatory factor analyses (CFAs), reliability analysis, and generalizability analysis. The SETQ questionnaires were tested in a sample of 3,025 physicians and 2,848 trainees in 46 hospitals. The CFA revealed acceptable fit of the data to the previously identified five-factor model. The high internal consistency estimates suggest satisfactory reliability of the subscales. These results provide robust evidence for the validity and reliability of the SETQ questionnaires for evaluating physicians' teaching performance. © The Author(s) 2014.

  8. Statistical summaries of fatigue data for design purposes

    NASA Technical Reports Server (NTRS)

    Wirsching, P. H.

    1983-01-01

    Two methods are discussed for constructing a design curve on the safe side of fatigue data. Both the tolerance interval and equivalent prediction interval (EPI) concepts provide such a curve while accounting for both the distribution of the estimators in small samples and the data scatter. The EPI is also useful as a mechanism for providing necessary statistics on S-N data for a full reliability analysis which includes uncertainty in all fatigue design factors. Examples of statistical analyses of the general strain life relationship are presented. The tolerance limit and EPI techniques for defining a design curve are demonstrated. Examples usng WASPALOY B and RQC-100 data demonstrate that a reliability model could be constructed by considering the fatigue strength and fatigue ductility coefficients as two independent random variables. A technique given for establishing the fatigue strength for high cycle lives relies on an extrapolation technique and also accounts for "runners." A reliability model or design value can be specified.

  9. Tissue tonometry is a simple, objective measure for pliability of burn scar: is it reliable?

    PubMed

    Lye, Ian; Edgar, Dale W; Wood, Fiona M; Carroll, Sara

    2006-01-01

    Objective measurement of burn scar response to treatment is important to facilitate individual patient care, research, and service development. This work examines the validity and reliability of the tonometer as a means of quantifying scar pliability. Ten burn survivors were recruited into the study. Triplicate measures were taken for each of four scar and one normal skin point. The pliability score from the Vancouver Scar Scale also was used as a comparison. The tonometer demonstrated a high degree of reliability (intraclass correlation coefficients 0.91-0.94). It also was shown to provide a valid measure of pliability by quantifying decreased tissue deformation for scar (2.04 +/- 0.45 mm) compared with normal tissue (3.02 +/- 0.92 mm; t = 4.28, P = .004) and a moderate correlation with Vancouver Scar Scale scores. The tissue tonometer provides a repeatable, objective index of burn scar pliability. Using the methods described, it is a simple, clinically useful technique for monitoring an individual's scar.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colldelram, Carles, E-mail: ccolldelram@cells.es; Nicolas, Josep, E-mail: jnicolas@cells.es; Nikitina, Liudmila, E-mail: lnikitina@cells.es

    In this work we report the design and performance of a novel compact in-vacuum actuator, designed to be compatible with all the motions required for the scissor-type ESRF mirror bender. These mirror benders include several linear actuators, which drive the mirror bending torques, as well as the main alignment motions such as pitch and translation along the normal to the mirror surface. The motions are provided by compact linear actuators, which consist of motor, reduction, spindle and nut, encapsulated on a closed air volume to provide vacuum compatibility. The actuator includes a hydroformed bellows to transmit the force to themore » actuator tip, and an electrical feedthrough for the motor cables. The design boundaries for these actuators are quite tight, as they must be integrated in a narrow volume, must be UHV compatible and must provide high resolution, for a relatively high load. As a result, they have limited mechanical performance, and in some cases poor reliability. To overcome these problems, we designed and implemented a different concept. In the proposed concept, the motor rotation is converted onto a linear motion by means of a cam instead of a spindle and a nut. This allows for much shorter and stiffer transmission system, with similar dimensions. The vacuum compatibility is intrinsic for this solution, since the whole mechanism of the actuator is UHV compatible. All motions are preloaded and guided by vacuum compatible (hybrid metal-ceramics) ball bearings. This allows the system reaching a repeatability and backlash well within the micron. The absence of friction allows for a high reliability and releases the maintenance needs of the system. The transmission is intrinsically irreversible, and the system can hold a load of 250 N within a few nanometers without any holding current on the motors. This allows the system to move reliably also in micro-stepping mode, providing a resolution well below the half-step nominal resolution of 100 nm. Performances have been tested on a prototype. We report the results of the tests obtained in air and in vacuum after bake-out. Two units of the new actuator have been installed at the photoemission beamline of ALBA (CIRCE) and are routinely used to align the 3 µm spot on the field of view of the Photoemission Electron Microscope. The absence of any noticeable backlash, or any friction effect and the reliability of the micro-stepping motion has simplified very much the alignment of the photon beam, reducing the alignment process to few minutes. The excellent performances and relatively high load capacity of this new compact actuator make of it a versatile element to be integrated in other systems requiring reliable in-vacuum positioning.« less

  11. Research on Energy-saving Shape Design of High School Library Building in Cold Region

    NASA Astrophysics Data System (ADS)

    Hui, Zhao; Weishuang, Xie; Zirui, Tong

    2017-11-01

    Considering climatic characteristics in cold region, existing high school libraries in Changchun are researched according to investigation of real conditions of these library buildings. Mathematical analysis and CAD methods are used to summarize the relation between building shape and building energy saving of high school library. Strategies are put forward for sustainable development of high school library building in cold region, providing reliable design basis for construction of high school libraries in Changchun.

  12. VHF Ranging and Position Fixing Experiment Using ATS Satellites: Final Report on Phases 1 and 2, 25 November 1968 - 1 May 1971

    NASA Technical Reports Server (NTRS)

    1971-01-01

    The testing program with the ATS-1 and ATS-3 spacecraft showed that geostationary satellites can provide superior communications and position surveillance for mobile craft. Inexpensive modifications to conventional mobile communications equipment aboard the craft can provide reliable, high quality voice and digital communications with distant ground stations and other vehicles, and automatic surveillance of the positions of all the craft by a ground facility. The tests also demonstrated the location and automatic readout of remote data collection platforms. Frequency modulation signals with the narrow audio and radio frequency bandwidths of terrestrial mobile radio communications were relayed through the VHF transponders of the geostationary satellites. The voice and digital communications were far superior in reliability and quality to long-distance mobile communications by other means. It was shown that one satellite can provide nearly uniform high quality performance over approximately one-third of the earth's surface. Position fixes by range measurement from the two satellites were accurate to approximately one nautical mile, except near the equator and the poles.

  13. Test-retest and between-site reliability in a multicenter fMRI study.

    PubMed

    Friedman, Lee; Stern, Hal; Brown, Gregory G; Mathalon, Daniel H; Turner, Jessica; Glover, Gary H; Gollub, Randy L; Lauriello, John; Lim, Kelvin O; Cannon, Tyrone; Greve, Douglas N; Bockholt, Henry Jeremy; Belger, Aysenil; Mueller, Bryon; Doty, Michael J; He, Jianchun; Wells, William; Smyth, Padhraic; Pieper, Steve; Kim, Seyoung; Kubicki, Marek; Vangel, Mark; Potkin, Steven G

    2008-08-01

    In the present report, estimates of test-retest and between-site reliability of fMRI assessments were produced in the context of a multicenter fMRI reliability study (FBIRN Phase 1, www.nbirn.net). Five subjects were scanned on 10 MRI scanners on two occasions. The fMRI task was a simple block design sensorimotor task. The impulse response functions to the stimulation block were derived using an FIR-deconvolution analysis with FMRISTAT. Six functionally-derived ROIs covering the visual, auditory and motor cortices, created from a prior analysis, were used. Two dependent variables were compared: percent signal change and contrast-to-noise-ratio. Reliability was assessed with intraclass correlation coefficients derived from a variance components analysis. Test-retest reliability was high, but initially, between-site reliability was low, indicating a strong contribution from site and site-by-subject variance. However, a number of factors that can markedly improve between-site reliability were uncovered, including increasing the size of the ROIs, adjusting for smoothness differences, and inclusion of additional runs. By employing multiple steps, between-site reliability for 3T scanners was increased by 123%. Dropping one site at a time and assessing reliability can be a useful method of assessing the sensitivity of the results to particular sites. These findings should provide guidance toothers on the best practices for future multicenter studies.

  14. Assessment of Caregiver Inventory for Rett Syndrome

    PubMed Central

    Lane, Jane B.; Salter, Amber R.; Jones, Nancy E.; Cutter, Gary; Horrigan, Joseph; Skinner, Steve A.; Kaufmann, Walter E.; Glaze, Daniel G.; Neul, Jeffrey L.; Percy, Alan K.

    2017-01-01

    Rett syndrome (RTT) requires total caregiver attention and leads to potential difficulties throughout life. The Caregiver Burden Inventory, designed for Alzheimer disease, was modified to a RTT Caregiver Inventory Assessment (RTT CIA). Reliability and face, construct, and concurrent validity were assessed in caregivers of individuals with RTT. Chi-square or Fisher’s exact test for categorical variables and t-tests or Wilcoxon two-sample tests for continuous variables were utilized. Survey completed by 198 caregivers; 70 caregivers completed follow-up assessment. Exploratory factor analysis revealed good agreement for Physical Burden, Emotional Burden, and Social Burden. Internal reliability was high (Cronbach’s alpha: 0.898). RTT CIA represents a reliable and valid measure, providing a needed metric of caregiver burden in this disorder. PMID:28132121

  15. Markov chains for testing redundant software

    NASA Technical Reports Server (NTRS)

    White, Allan L.; Sjogren, Jon A.

    1988-01-01

    A preliminary design for a validation experiment has been developed that addresses several problems unique to assuring the extremely high quality of multiple-version programs in process-control software. The procedure uses Markov chains to model the error states of the multiple version programs. The programs are observed during simulated process-control testing, and estimates are obtained for the transition probabilities between the states of the Markov chain. The experimental Markov chain model is then expanded into a reliability model that takes into account the inertia of the system being controlled. The reliability of the multiple version software is computed from this reliability model at a given confidence level using confidence intervals obtained for the transition probabilities during the experiment. An example demonstrating the method is provided.

  16. Reliability of a rating procedure to monitor industry self-regulation codes governing alcohol advertising content.

    PubMed

    Babor, Thomas F; Xuan, Ziming; Proctor, Dwayne

    2008-03-01

    The purposes of this study were to develop reliable procedures to monitor the content of alcohol advertisements broadcast on television and in other media, and to detect violations of the content guidelines of the alcohol industry's self-regulation codes. A set of rating-scale items was developed to measure the content guidelines of the 1997 version of the U.S. Beer Institute Code. Six focus groups were conducted with 60 college students to evaluate the face validity of the items and the feasibility of the procedure. A test-retest reliability study was then conducted with 74 participants, who rated five alcohol advertisements on two occasions separated by 1 week. Average correlations across all advertisements using three reliability statistics (r, rho, and kappa) were almost all statistically significant and the kappas were good for most items, which indicated high test-retest agreement. We also found high interrater reliabilities (intraclass correlations) among raters for item-level and guideline-level violations, indicating that regardless of the specific item, raters were consistent in their general evaluations of the advertisements. Naïve (untrained) raters can provide consistent (reliable) ratings of the main content guidelines proposed in the U.S. Beer Institute Code. The rating procedure may have future applications for monitoring compliance with industry self-regulation codes and for conducting research on the ways in which alcohol advertisements are perceived by young adults and other vulnerable populations.

  17. Research of vibration controlling based on programmable logic controller for electrostatic precipitator

    NASA Astrophysics Data System (ADS)

    Zhang, Zisheng; Li, Yanhu; Li, Jiaojiao; Liu, Zhiqiang; Li, Qing

    2013-03-01

    In order to improve the reliability, stability and automation of electrostatic precipitator, circuits of vibration motor for ESP and vibration control ladder diagram program are investigated using Schneider PLC with high performance and programming software of Twidosoft. Operational results show that after adopting PLC, vibration motor can run automatically; compared with traditional control system of vibration based on single-chip microcomputer, it has higher reliability, better stability and higher dust removal rate, when dust emission concentrations <= 50 mg m-3, providing a new method for vibration controlling of ESP.

  18. Formal design and verification of a reliable computing platform for real-time control. Phase 2: Results

    NASA Technical Reports Server (NTRS)

    Butler, Ricky W.; Divito, Ben L.

    1992-01-01

    The design and formal verification of the Reliable Computing Platform (RCP), a fault tolerant computing system for digital flight control applications is presented. The RCP uses N-Multiply Redundant (NMR) style redundancy to mask faults and internal majority voting to flush the effects of transient faults. The system is formally specified and verified using the Ehdm verification system. A major goal of this work is to provide the system with significant capability to withstand the effects of High Intensity Radiated Fields (HIRF).

  19. Managing Complexity in Next Generation Robotic Spacecraft: From a Software Perspective

    NASA Technical Reports Server (NTRS)

    Reinholtz, Kirk

    2008-01-01

    This presentation highlights the challenges in the design of software to support robotic spacecraft. Robotic spacecraft offer a higher degree of autonomy, however currently more capabilities are required, primarily in the software, while providing the same or higher degree of reliability. The complexity of designing such an autonomous system is great, particularly while attempting to address the needs for increased capabilities and high reliability without increased needs for time or money. The efforts to develop programming models for the new hardware and the integration of software architecture are highlighted.

  20. Detection of early psychotic symptoms: Validation of the Spanish version of the "Symptom Onset in Schizophrenia (SOS) inventory".

    PubMed

    Mezquida, Gisela; Cabrera, Bibiana; Martínez-Arán, Anabel; Vieta, Eduard; Bernardo, Miguel

    2018-03-01

    The period of subclinical signs that precedes the onset of psychosis is referred to as the prodrome or high-risk mental state. The "Symptom Onset in Schizophrenia (SOS) inventory" is an instrument to characterize and date the initial symptoms of a psychotic illness. The present study aims to provide reliability and validity data for clinical and research use of the Spanish version of the SOS. Thirty-six participants with a first-episode of psychosis meeting DSM-IV criteria for schizophrenia/schizoaffective/schizophreniform disorder were administered the translated SOS and other clinical assessments. The internal validity, intrarater and interrater reliability were studied. We found strong interrater reliability. To detect the presence/absence of prodromal symptoms, Kappa coefficients ranged between 0.8 and 0.7. Similarly, the raters obtained an excellent level of agreement regarding the onset of each symptom and the duration of symptoms until first treatment (intraclass correlation coefficients between 0.9 and 1.0). Cronbach's alpha was 0.9-1.0 for all the items. The interrater reliability and concurrent validity were also excellent in both cases. This study provides robust psychometric properties of the Spanish version of the SOS. The translated version is adequate in terms of good internal validity, intrarater and interrater reliability, and is as time-efficient as the original version. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. CSBF Engineering Overview

    NASA Astrophysics Data System (ADS)

    Orr, Dwayne

    The Columbia Scientific Balloon Facility (CSBF) at Palestine, Texas provides operational and engineering support for the launch of NASA Scientific Balloons. Over the years with the support of the NASA Balloon Program Office, CSBF has developed unique flight systems with the focus of providing a highly reliable, cost effective medium for giving Scientist's access to a near space environment. This paper will provide an overview of the CSBF flight systems with an emphasis on recent developments and plans for the future including: RIP Stitch -Parachute Shock Attenuation system, MIP -Micro Instrumentation Package, GAPR -Gondola Automatic Parachute Release system, NASA TDRSS High Gain Antenna system, Superpressure flight video systems

  2. Reliability of an Automated High-Resolution Manometry Analysis Program across Expert Users, Novice Users, and Speech-Language Pathologists

    ERIC Educational Resources Information Center

    Jones, Corinne A.; Hoffman, Matthew R.; Geng, Zhixian; Abdelhalim, Suzan M.; Jiang, Jack J.; McCulloch, Timothy M.

    2014-01-01

    Purpose: The purpose of this study was to investigate inter- and intrarater reliability among expert users, novice users, and speech-language pathologists with a semiautomated high-resolution manometry analysis program. We hypothesized that all users would have high intrarater reliability and high interrater reliability. Method: Three expert…

  3. Regulated Capacitor Charging Circuit Using a High Reactance Transformer

    DTIC Science & Technology

    1999-06-01

    REGULATED CAPACITOR CHARGING CIRCUIT USING A HIGH REACTANCE TRANSFORMER1 Diana L. Loree and James P. O’Loughlin Air Force Research Laboratory...Directed Energy Directorate Kirtland Air Force Base, NM 87117-5776 Abstract A high reactance transformer circuit is used to provide for the compact...simple, economic and reliable charging of a capacitor energy store to a predetermined and regulated voltage. The circuit can be operated from a

  4. Apparatus, components and operating methods for circulating fluidized bed transport gasifiers and reactors

    DOEpatents

    Vimalchand, Pannalal; Liu, Guohai; Peng, Wan Wang

    2015-02-24

    The improvements proposed in this invention provide a reliable apparatus and method to gasify low rank coals in a class of pressurized circulating fluidized bed reactors termed "transport gasifier." The embodiments overcome a number of operability and reliability problems with existing gasifiers. The systems and methods address issues related to distribution of gasification agent without the use of internals, management of heat release to avoid any agglomeration and clinker formation, specific design of bends to withstand the highly erosive environment due to high solid particles circulation rates, design of a standpipe cyclone to withstand high temperature gasification environment, compact design of seal-leg that can handle high mass solids flux, design of nozzles that eliminate plugging, uniform aeration of large diameter Standpipe, oxidant injection at the cyclone exits to effectively modulate gasifier exit temperature and reduction in overall height of the gasifier with a modified non-mechanical valve.

  5. Health management and controls for Earth-to-orbit propulsion systems

    NASA Astrophysics Data System (ADS)

    Bickford, R. L.

    1995-03-01

    Avionics and health management technologies increase the safety and reliability while decreasing the overall cost for Earth-to-orbit (ETO) propulsion systems. New ETO propulsion systems will depend on highly reliable fault tolerant flight avionics, advanced sensing systems and artificial intelligence aided software to ensure critical control, safety and maintenance requirements are met in a cost effective manner. Propulsion avionics consist of the engine controller, actuators, sensors, software and ground support elements. In addition to control and safety functions, these elements perform system monitoring for health management. Health management is enhanced by advanced sensing systems and algorithms which provide automated fault detection and enable adaptive control and/or maintenance approaches. Aerojet is developing advanced fault tolerant rocket engine controllers which provide very high levels of reliability. Smart sensors and software systems which significantly enhance fault coverage and enable automated operations are also under development. Smart sensing systems, such as flight capable plume spectrometers, have reached maturity in ground-based applications and are suitable for bridging to flight. Software to detect failed sensors has reached similar maturity. This paper will discuss fault detection and isolation for advanced rocket engine controllers as well as examples of advanced sensing systems and software which significantly improve component failure detection for engine system safety and health management.

  6. Supporting Technology at GRC to Mitigate Risk as Stirling Power Conversion Transitions to Flight

    NASA Technical Reports Server (NTRS)

    Schreiber, Jeffrey G.; Thieme, Lanny G.; Wong, Wayne A.

    2009-01-01

    Stirling power conversion technology has been reaching more advanced levels of maturity during its development for space power applications. The current effort is in support of the Advanced Stirling Radioisotope Generator (ASRG), which is being developed by the U.S. Department of Energy (DOE), Lockheed Martin Space Systems Company (LMSSC), Sunpower Inc., and the NASA Glenn Research Center (GRC). This generator would use two high-efficiency Advanced Stirling Convertors (ASCs) to convert thermal energy from a radioisotope heat source into electricity. Of paramount importance is the reliability of the power system and as a part of this, the Stirling power convertors. GRC has established a supporting technology effort with tasks in the areas of reliability, convertor testing, high-temperature materials, structures, advanced analysis, organics, and permanent magnets. The project utilizes the matrix system at GRC to make use of resident experts in each of the aforementioned fields. Each task is intended to reduce risk and enhance reliability of the convertor as this technology transitions toward flight status. This paper will provide an overview of each task, outline the recent efforts and accomplishments, and show how they mitigate risk and impact the reliability of the ASC s and ultimately, the ASRG.

  7. Real-Time GNSS-Based Attitude Determination in the Measurement Domain.

    PubMed

    Zhao, Lin; Li, Na; Li, Liang; Zhang, Yi; Cheng, Chun

    2017-02-05

    A multi-antenna-based GNSS receiver is capable of providing high-precision and drift-free attitude solution. Carrier phase measurements need be utilized to achieve high-precision attitude. The traditional attitude determination methods in the measurement domain and the position domain resolve the attitude and the ambiguity sequentially. The redundant measurements from multiple baselines have not been fully utilized to enhance the reliability of attitude determination. A multi-baseline-based attitude determination method in the measurement domain is proposed to estimate the attitude parameters and the ambiguity simultaneously. Meanwhile, the redundancy of attitude resolution has also been increased so that the reliability of ambiguity resolution and attitude determination can be enhanced. Moreover, in order to further improve the reliability of attitude determination, we propose a partial ambiguity resolution method based on the proposed attitude determination model. The static and kinematic experiments were conducted to verify the performance of the proposed method. When compared with the traditional attitude determination methods, the static experimental results show that the proposed method can improve the accuracy by at least 0.03° and enhance the continuity by 18%, at most. The kinematic result has shown that the proposed method can obtain an optimal balance between accuracy and reliability performance.

  8. Supporting Technology at GRC to Mitigate Risk as Stirling Power Conversion Transitions to Flight

    NASA Technical Reports Server (NTRS)

    Schreiber, Jeffrey G.; Thieme, Lanny G.; Wong, Wayne A.

    2008-01-01

    Stirling power conversion technology has been reaching more advanced levels of maturity during its development for space power applications. The current effort is in support of the Advanced Stirling Radioisotope Generator (ASRG), which is being developed by the U.S. Department of Energy (DOE), Lockheed Martin Space Systems Company (LMSSC), Sunpower Inc., and the NASA Glenn Research Center (GRC). This generator would use two high-efficiency Advanced Stirling Convertors (ASCs) to convert thermal energy from a radioisotope heat source into electricity. Of paramount importance is the reliability of the power system and as a part of this, the Stirling power convertors. GRC has established a supporting technology effort with tasks in the areas of reliability, convertor testing, high-temperature materials, structures, advanced analysis, organics, and permanent magnets. The project utilizes the matrix system at GRC to make use of resident experts in each of the aforementioned fields. Each task is intended to reduce risk and enhance reliability of the convertor as this technology transitions toward flight status. This paper will provide an overview of each task, outline the recent efforts and accomplishments, and show how they mitigate risk and impact the reliability of the ASC s and ultimately, the ASRG.

  9. Signal modulation as a mechanism for handicap disposal

    PubMed Central

    Gavassa, Sat; Silva, Ana C.; Gonzalez, Emmanuel; Stoddard, Philip K.

    2012-01-01

    Signal honesty may be compromised when heightened competition provides incentive for signal exaggeration. Some degree of honesty might be maintained by intrinsic handicap costs on signalling or through imposition of extrinsic costs, such as social punishment of low quality cheaters. Thus, theory predicts a delicate balance between signal enhancement and signal reliability that varies with degree of social competition, handicap cost, and social cost. We investigated whether male sexual signals of the electric fish Brachyhypopomus gauderio would become less reliable predictors of body length when competition provides incentives for males to boost electric signal amplitude. As expected, social competition under natural field conditions and in controlled lab experiments drove males to enhance their signals. However, signal enhancement improved the reliability of the information conveyed by the signal, as revealed in the tightening of the relationship between signal amplitude and body length. Signal augmentation in male B. gauderio was independent of body length, and thus appeared not to be curtailed through punishment of low quality (small) individuals. Rather, all individuals boosted their signals under high competition, but those whose signals were farthest from the predicted value under low competition boosted signal amplitude the most. By elimination, intrinsic handicap cost of signal production, rather than extrinsic social cost, appears to be the basis for the unexpected reinforcement of electric signal honesty under social competition. Signal modulation may provide its greatest advantage to the signaller as a mechanism for handicap disposal under low competition rather than as a mechanism for exaggeration of quality under high competition. PMID:22665940

  10. Next-generation sequencing is a robust strategy for the high-throughput detection of zygosity in transgenic maize.

    PubMed

    Fritsch, Leonie; Fischer, Rainer; Wambach, Christoph; Dudek, Max; Schillberg, Stefan; Schröper, Florian

    2015-08-01

    Simple and reliable, high-throughput techniques to detect the zygosity of transgenic events in plants are valuable for biotechnology and plant breeding companies seeking robust genotyping data for the assessment of new lines and the monitoring of breeding programs. We show that next-generation sequencing (NGS) applied to short PCR products spanning the transgene integration site provides accurate zygosity data that are more robust and reliable than those generated by PCR-based methods. The NGS reads covered the 5' border of the transgenic events (incorporating part of the transgene and the flanking genomic DNA), or the genomic sequences flanking the unfilled transgene integration site at the wild-type locus. We compared the NGS method to competitive real-time PCR with transgene-specific and wild-type-specific primer/probe pairs, one pair matching the 5' genomic flanking sequence and 5' part of the transgene and the other matching the unfilled transgene integration site. Although both NGS and real-time PCR provided useful zygosity data, the NGS technique was favorable because it needed fewer optimization steps. It also provided statistically more-reliable evidence for the presence of each allele because each product was often covered by more than 100 reads. The NGS method is also more suitable for the genotyping of large panels of plants because up to 80 million reads can be produced in one sequencing run. Our novel method is therefore ideal for the rapid and accurate genotyping of large numbers of samples.

  11. The Xpress Transfer Protocol (XTP): A tutorial (expanded version)

    NASA Technical Reports Server (NTRS)

    Sanders, Robert M.; Weaver, Alfred C.

    1990-01-01

    The Xpress Transfer Protocol (XTP) is a reliable, real-time, light weight transfer layer protocol. Current transport layer protocols such as DoD's Transmission Control Protocol (TCP) and ISO's Transport Protocol (TP) were not designed for the next generation of high speed, interconnected reliable networks such as fiber distributed data interface (FDDI) and the gigabit/second wide area networks. Unlike all previous transport layer protocols, XTP is being designed to be implemented in hardware as a VLSI chip set. By streamlining the protocol, combining the transport and network layers and utilizing the increased speed and parallelization possible with a VLSI implementation, XTP will be able to provide the end-to-end data transmission rates demanded in high speed networks without compromising reliability and functionality. This paper describes the operation of the XTP protocol and in particular, its error, flow and rate control; inter-networking addressing mechanisms; and multicast support features, as defined in the XTP Protocol Definition Revision 3.4.

  12. Advanced Stirling Convertor Testing at NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Wilson, Scott D.; Poriti, Sal

    2010-01-01

    The NASA Glenn Research Center (GRC) has been testing high-efficiency free-piston Stirling convertors for potential use in radioisotope power systems (RPSs) since 1999. The current effort is in support of the Advanced Stirling Radioisotope Generator (ASRG), which is being developed by the U.S. Department of Energy (DOE), Lockheed Martin Space Systems Company (LMSSC), Sunpower, Inc., and the NASA GRC. This generator would use two high-efficiency Advanced Stirling Convertors (ASCs) to convert thermal energy from a radioisotope heat source into electricity. As reliability is paramount to a RPS capable of providing spacecraft power for potential multi-year missions, GRC provides direct technology support to the ASRG flight project in the areas of reliability, convertor and generator testing, high-temperature materials, structures, modeling and analysis, organics, structural dynamics, electromagnetic interference (EMI), and permanent magnets to reduce risk and enhance reliability of the convertor as this technology transitions toward flight status. Convertor and generator testing is carried out in short- and long-duration tests designed to characterize convertor performance when subjected to environments intended to simulate launch and space conditions. Long duration testing is intended to baseline performance and observe any performance degradation over the life of the test. Testing involves developing support hardware that enables 24/7 unattended operation and data collection. GRC currently has 14 Stirling convertors under unattended extended operation testing, including two operating in the ASRG Engineering Unit (ASRG-EU). Test data and high-temperature support hardware are discussed for ongoing and future ASC tests with emphasis on the ASC-E and ASC-E2.

  13. Explosion Clad for Upstream Oil and Gas Equipment

    NASA Astrophysics Data System (ADS)

    Banker, John G.; Massarello, Jack; Pauly, Stephane

    2011-01-01

    Today's upstream oil and gas facilities frequently involve the combination of high pressures, high temperatures, and highly corrosive environments, requiring equipment that is thick wall, corrosion resistant, and cost effective. When significant concentrations of CO2 and/or H2S and/or chlorides are present, corrosion resistant alloys (CRA) can become the material of choice for separator equipment, piping, related components, and line pipe. They can provide reliable resistance to both corrosion and hydrogen embrittlement. For these applications, the more commonly used CRA's are 316L, 317L and duplex stainless steels, alloy 825 and alloy 625, dependent upon the application and the severity of the environment. Titanium is also an exceptional choice from the technical perspective, but is less commonly used except for heat exchangers. Explosion clad offers significant savings by providing a relatively thin corrosion resistant alloy on the surface metallurgically bonded to a thick, lower cost, steel substrate for the pressure containment. Developed and industrialized in the 1960's the explosion cladding technology can be used for cladding the more commonly used nickel based and stainless steel CRA's as well as titanium. It has many years of proven experience as a reliable and highly robust clad manufacturing process. The unique cold welding characteristics of explosion cladding reduce problems of alloy sensitization and dissimilar metal incompatibility. Explosion clad materials have been used extensively in both upstream and downstream oil, gas and petrochemical facilities for well over 40 years. The explosion clad equipment has demonstrated excellent resistance to corrosion, embrittlement and disbonding. Factors critical to insure reliable clad manufacture and equipment design and fabrication are addressed.

  14. A simple video-based timing system for on-ice team testing in ice hockey: a technical report.

    PubMed

    Larson, David P; Noonan, Benjamin C

    2014-09-01

    The purpose of this study was to describe and evaluate a newly developed on-ice timing system for team evaluation in the sport of ice hockey. We hypothesized that this new, simple, inexpensive, timing system would prove to be highly accurate and reliable. Six adult subjects (age 30.4 ± 6.2 years) performed on ice tests of acceleration and conditioning. The performance times of the subjects were recorded using a handheld stopwatch, photocell, and high-speed (240 frames per second) video. These results were then compared to allow for accuracy calculations of the stopwatch and video as compared with filtered photocell timing that was used as the "gold standard." Accuracy was evaluated using maximal differences, typical error/coefficient of variation (CV), and intraclass correlation coefficients (ICCs) between the timing methods. The reliability of the video method was evaluated using the same variables in a test-retest analysis both within and between evaluators. The video timing method proved to be both highly accurate (ICC: 0.96-0.99 and CV: 0.1-0.6% as compared with the photocell method) and reliable (ICC and CV within and between evaluators: 0.99 and 0.08%, respectively). This video-based timing method provides a very rapid means of collecting a high volume of very accurate and reliable on-ice measures of skating speed and conditioning, and can easily be adapted to other testing surfaces and parameters.

  15. Reliability and Validity Evidence for Achievement Goal Models in High School Physical Education Settings

    ERIC Educational Resources Information Center

    Guan, Jianmin; McBride, Ron; Xiang, Ping

    2007-01-01

    Although empirical research in academic areas provides support for both a 3-factor as well as a 4-factor achievement goal model, both models were proposed and tested with a collegiate sample. Little is known about the generalizability of either model with high school level samples. This study was designed to examine whether the 3-factor model…

  16. Photogrammetric Point Clouds Generation in Urban Areas from Integrated Image Matching and Segmentation

    NASA Astrophysics Data System (ADS)

    Ye, L.; Wu, B.

    2017-09-01

    High-resolution imagery is an attractive option for surveying and mapping applications due to the advantages of high quality imaging, short revisit time, and lower cost. Automated reliable and dense image matching is essential for photogrammetric 3D data derivation. Such matching, in urban areas, however, is extremely difficult, owing to the complexity of urban textures and severe occlusion problems on the images caused by tall buildings. Aimed at exploiting high-resolution imagery for 3D urban modelling applications, this paper presents an integrated image matching and segmentation approach for reliable dense matching of high-resolution imagery in urban areas. The approach is based on the framework of our existing self-adaptive triangulation constrained image matching (SATM), but incorporates three novel aspects to tackle the image matching difficulties in urban areas: 1) occlusion filtering based on image segmentation, 2) segment-adaptive similarity correlation to reduce the similarity ambiguity, 3) improved dense matching propagation to provide more reliable matches in urban areas. Experimental analyses were conducted using aerial images of Vaihingen, Germany and high-resolution satellite images in Hong Kong. The photogrammetric point clouds were generated, from which digital surface models (DSMs) were derived. They were compared with the corresponding airborne laser scanning data and the DSMs generated from the Semi-Global matching (SGM) method. The experimental results show that the proposed approach is able to produce dense and reliable matches comparable to SGM in flat areas, while for densely built-up areas, the proposed method performs better than SGM. The proposed method offers an alternative solution for 3D surface reconstruction in urban areas.

  17. Demand Response For Power System Reliability: FAQ

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kirby, Brendan J

    2006-12-01

    Demand response is the most underutilized power system reliability resource in North America. Technological advances now make it possible to tap this resource to both reduce costs and improve. Misconceptions concerning response capabilities tend to force loads to provide responses that they are less able to provide and often prohibit them from providing the most valuable reliability services. Fortunately this is beginning to change with some ISOs making more extensive use of load response. This report is structured as a series of short questions and answers that address load response capabilities and power system reliability needs. Its objective is tomore » further the use of responsive load as a bulk power system reliability resource in providing the fastest and most valuable ancillary services.« less

  18. Providing reliable route guidance : phase II.

    DOT National Transportation Integrated Search

    2010-12-20

    The overarching goal of the project is to enhance travel reliability of highway users by providing : them with reliable route guidance produced from newly developed routing algorithms that : are validated and implemented with real traffic data. To th...

  19. Accounting for test reliability in student progression: the reliable change index.

    PubMed

    Zahra, Daniel; Hedge, Craig; Pesola, Francesca; Burr, Steven

    2016-07-01

    Developed by Jacobson and Truax, the reliable change index (RCI) provides a measure of whether the change in an individual's score over time is within or beyond that which might be accounted for by measurement variability. In combination with measures of whether an individual's final score is closer to those of one population or another, this provides useful individual-level information that can be used to supplement traditional analyses. This article aims to highlight the potential of the RCI for use within medical education, particularly as a novel means of monitoring progress at the student level across successive test occasions or academic years. We provide an example of how the RCI can be applied informatively to assessment evaluation, and discuss its wider usage. The RCI approach can be used to identify and support failing students, as well as to determine best teaching and learning practices by identifying high-performing students. Furthermore, the individual-level nature of the RCI makes it well suited for educational research with small cohorts, as well as for tracking individual profiles within a larger cohort or addressing questions about individual performance that may be unanswerable at group level. © 2016 John Wiley & Sons Ltd.

  20. System Analysis and Performance Benefits of an Optimized Rotorcraft Propulsion System

    NASA Technical Reports Server (NTRS)

    Bruckner, Robert J.

    2007-01-01

    The propulsion system of rotorcraft vehicles is the most critical system to the vehicle in terms of safety and performance. The propulsion system must provide both vertical lift and forward flight propulsion during the entire mission. Whereas propulsion is a critical element for all flight vehicles, it is particularly critical for rotorcraft due to their limited safe, un-powered landing capability. This unparalleled reliability requirement has led rotorcraft power plants down a certain evolutionary path in which the system looks and performs quite similarly to those of the 1960 s. By and large the advancements in rotorcraft propulsion have come in terms of safety and reliability and not in terms of performance. The concept of the optimized propulsion system is a means by which both reliability and performance can be improved for rotorcraft vehicles. The optimized rotorcraft propulsion system which couples an oil-free turboshaft engine to a highly loaded gearbox that provides axial load support for the power turbine can be designed with current laboratory proven technology. Such a system can provide up to 60% weight reduction of the propulsion system of rotorcraft vehicles. Several technical challenges are apparent at the conceptual design level and should be addressed with current research.

  1. Microwave-triggered laser switch

    DOEpatents

    Piltch, M.S.

    1982-05-19

    A high-repetition rate switch is described for delivering short duration, high-powered electrical pulses from a pulsed-charged dc power supply. The present invention utilizes a microwave-generating device such as a magnetron that is capable of producing high-power pulses at high-pulse repetition rates and fast-pulse risetimes for long periods with high reliability. The rail-gap electrodes provide a large surface area that reduces induction effects and minimizes electrode erosion. Additionally, breakdown is initiated in a continuous geometric fashion that also increases operating lifetime of the device.

  2. Microwave-triggered laser switch

    DOEpatents

    Piltch, Martin S.

    1984-01-01

    A high-repetition rate switch for delivering short duration, high-power electrical pulses from a pulsed-charged dc power supply. The present invention utilizes a microwave-generating device such as a magnetron that is capable of producing high-power pulses at high-pulse repetition rates and fast-pulse risetimes for long periods with high reliability. The rail-gap electrodes provide a large surface area that reduces induction effects and minimizes electrode erosion. Additionally, breakdown is initiated in a continuous geometric fashion that also increases operating lifetime of the device.

  3. Low-grade geothermal energy conversion by organic Rankine cycle turbine generator

    NASA Astrophysics Data System (ADS)

    Zarling, J. P.; Aspnes, J. D.

    Results of a demonstration project which helped determine the feasibility of converting low-grade thermal energy in 49 C water into electrical energy via an organic Rankine cycle 2500 watt (electrical) turbine-generator are presented. The geothermal source which supplied the water is located in a rural Alaskan village. The reasons an organic Rankine cycle turbine-generator was investigated as a possible source of electric power in rural Alaska are: (1) high cost of operating diesel-electric units and their poor long-term reliability when high-quality maintenance is unavailable and (2) the extremely high level of long-term reliability reportedly attained by commercially available organic Rankine cycle turbines. Data is provided on the thermal and electrical operating characteristics of an experimental organic Rankine cycle turbine-generator operating at a uniquely low vaporizer temperature.

  4. Reliability of muscle strength assessment in chronic post-stroke hemiparesis: a systematic review and meta-analysis.

    PubMed

    Rabelo, Michelle; Nunes, Guilherme S; da Costa Amante, Natália Menezes; de Noronha, Marcos; Fachin-Martins, Emerson

    2016-02-01

    Muscle weakness is the main cause of motor impairment among stroke survivors and is associated with reduced peak muscle torque. To systematically investigate and organize the evidence of the reliability of muscle strength evaluation measures in post-stroke survivors with chronic hemiparesis. Two assessors independently searched four electronic databases in January 2014 (Medline, Scielo, CINAHL, Embase). Inclusion criteria comprised studies on reliability on muscle strength assessment in adult post-stroke patients with chronic hemiparesis. We extracted outcomes from included studies about reliability data, measured by intraclass correlation coefficient (ICC) and/or similar. The meta-analyses were conducted only with isokinetic data. Of 450 articles, eight articles were included for this review. After quality analysis, two studies were considered of high quality. Five different joints were analyzed within the included studies (knee, hip, ankle, shoulder, and elbow). Their reliability results varying from low to very high reliability (ICCs from 0.48 to 0.99). Results of meta-analysis for knee extension varying from high to very high reliability (pooled ICCs from 0.89 to 0.97), for knee flexion varying from high to very high reliability (pooled ICCs from 0.84 to 0.91) and for ankle plantar flexion showed high reliability (pooled ICC = 0.85). Objective muscle strength assessment can be reliably used in lower and upper extremities in post-stroke patients with chronic hemiparesis.

  5. Electric-Field Instrument With Ac-Biased Corona Point

    NASA Technical Reports Server (NTRS)

    Markson, R.; Anderson, B.; Govaert, J.

    1993-01-01

    Measurements indicative of incipient lightning yield additional information. New instrument gives reliable readings. High-voltage ac bias applied to needle point through high-resistance capacitance network provides corona discharge at all times, enabling more-slowly-varying component of electrostatic potential of needle to come to equilibrium with surrounding air. High resistance of high-voltage coupling makes instrument insensitive to wind. Improved corona-point instrument expected to yield additional information assisting in safety-oriented forecasting of lighting.

  6. Development, content validity and test-retest reliability of the Lifelong Physical Activity Skills Battery in adolescents.

    PubMed

    Hulteen, Ryan M; Barnett, Lisa M; Morgan, Philip J; Robinson, Leah E; Barton, Christian J; Wrotniak, Brian H; Lubans, David R

    2018-03-28

    Numerous skill batteries assess fundamental motor skill (e.g., kick, hop) competence. Few skill batteries examine lifelong physical activity skill competence (e.g., resistance training). This study aimed to develop and assess the content validity, test-retest and inter-rater reliability of the "Lifelong Physical Activity Skills Battery". Development of the skill battery occurred in three stages: i) systematic reviews of lifelong physical activity participation rates and existing motor skill assessment tools, ii) practitioner consultation and iii) research expert consultation. The final battery included eight skills: grapevine, golf swing, jog, push-up, squat, tennis forehand, upward dog and warrior I. Adolescents (28 boys, 29 girls; M = 15.8 years, SD = 0.4 years) completed the Lifelong Physical Activity Skills Battery on two occasions two weeks apart. The skill battery was highly reliable (ICC = 0.84, 95% CI = 0.72-0.90) with individual skill reliability scores ranging from moderate (warrior I; ICC = 0.56) to high (tennis forehand; ICC = 0.82). Typical error (4.0; 95% CI 3.4-5.0) and proportional bias (r = -0.21, p = .323) were low. This study has provided preliminary evidence for the content validity and reliability of the Lifelong Physical Activity Skills Battery in an adolescent population.

  7. High burn-up spent nuclear fuel transport reliability investigation

    DOE PAGES

    Wang, Jy-An; Wang, Hong; Jiang, Hao; ...

    2018-04-15

    Transportation packages for spent nuclear fuel (SNF) must meet safety requirements under normal and accident conditions as specified by federal regulations. During road or rail transportation, SNF will experience unique conditions that could affect the structural integrity of the cladding due to vibrational and impact loading. Lack of SNF inertia-induced dynamic fatigue data, especially for the high burn-up (HBU) SNF systems, has brought significant challenges to quantify the reliability of SNF during transportation with a high degree of confidence. To address this shortcoming, Oak Ridge National Laboratory (ORNL) developed a SNF vibration testing protocol without fuel pellets removal, which hasmore » provided significant insight regarding the dynamics of mechanical interactions between pellet and cladding. This research has provided a detailed understanding about the effect of loading rate and loading mode on the fatigue damage evolution of HBU SNF under normal conditions of transport (NCT). Static and dynamic loading experimental data were generated for SNF under simulated transportation environments using a cyclic integrated reversible-bending fatigue tester (CIRFT), an enabling hot-cell testing technology developed at ORNL. SNF flexural tensile strength and fatigue S-N data from pressurized water reactors (PWRs) and boiling water reactor (BWR) HBU SNF are presented in this paper, including the potential effects of pellet-cladding interface bonding, hydride reorientation, and thermal annealing to SNF vibration reliability. The data presented here can be used to meet the nuclear industry and U.S. Nuclear Regulatory Commission needs in safety of SNF transportation operations.« less

  8. High burn-up spent nuclear fuel transport reliability investigation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Jy-An; Wang, Hong; Jiang, Hao

    Transportation packages for spent nuclear fuel (SNF) must meet safety requirements under normal and accident conditions as specified by federal regulations. During road or rail transportation, SNF will experience unique conditions that could affect the structural integrity of the cladding due to vibrational and impact loading. Lack of SNF inertia-induced dynamic fatigue data, especially for the high burn-up (HBU) SNF systems, has brought significant challenges to quantify the reliability of SNF during transportation with a high degree of confidence. To address this shortcoming, Oak Ridge National Laboratory (ORNL) developed a SNF vibration testing protocol without fuel pellets removal, which hasmore » provided significant insight regarding the dynamics of mechanical interactions between pellet and cladding. This research has provided a detailed understanding about the effect of loading rate and loading mode on the fatigue damage evolution of HBU SNF under normal conditions of transport (NCT). Static and dynamic loading experimental data were generated for SNF under simulated transportation environments using a cyclic integrated reversible-bending fatigue tester (CIRFT), an enabling hot-cell testing technology developed at ORNL. SNF flexural tensile strength and fatigue S-N data from pressurized water reactors (PWRs) and boiling water reactor (BWR) HBU SNF are presented in this paper, including the potential effects of pellet-cladding interface bonding, hydride reorientation, and thermal annealing to SNF vibration reliability. The data presented here can be used to meet the nuclear industry and U.S. Nuclear Regulatory Commission needs in safety of SNF transportation operations.« less

  9. Choice of rating scale labels: implication for minimizing patient satisfaction response ceiling effect in telemedicine surveys.

    PubMed

    Masino, Caterina; Lam, Tony C M

    2014-12-01

    Lack of response variability is problematic in surveys because of its detrimental effects on sensitivity and consequently reliability of the responses. In satisfaction surveys, this problem is caused by the ceiling effect resulting from high satisfaction ratings. A potential solution strategy is to manipulate the labels of the rating scale to create greater discrimination of responses on the high end of the response continuum. This study examined the effects of a positive-centered scale on the distribution and reliability of telemedicine satisfaction responses in a highly positive respondent population. In total, 216 telemedicine participants were randomly assigned to one of three experimental conditions as defined by the form of Likert scale: (1) 5-point Balanced Equal-Interval, (2) 5-point Positive-Packed, and (3) 5-point Positive-Centered Equal-Interval. Although the study findings were not statistically significant, partially because of sample size, the distribution and internal consistency reliability of responses occurred in the direction hypothesized. Loading the rating scale with more positive labels appears to be a useful strategy for reducing the ceiling effect and increases the discrimination ability of survey responses. The current research provides a survey design strategy to minimize ceiling effects. Although the findings provide some evidence suggesting the benefit of using rating scales loaded with positive labels, more research is needed to confirm this, as well as extend it to examine other types of rating scales and the interaction between rating scale formats and respondent characteristics.

  10. Spatial Correlations in Natural Scenes Modulate Response Reliability in Mouse Visual Cortex

    PubMed Central

    Rikhye, Rajeev V.

    2015-01-01

    Intrinsic neuronal variability significantly limits information encoding in the primary visual cortex (V1). Certain stimuli can suppress this intertrial variability to increase the reliability of neuronal responses. In particular, responses to natural scenes, which have broadband spatiotemporal statistics, are more reliable than responses to stimuli such as gratings. However, very little is known about which stimulus statistics modulate reliable coding and how this occurs at the neural ensemble level. Here, we sought to elucidate the role that spatial correlations in natural scenes play in reliable coding. We developed a novel noise-masking method to systematically alter spatial correlations in natural movies, without altering their edge structure. Using high-speed two-photon calcium imaging in vivo, we found that responses in mouse V1 were much less reliable at both the single neuron and population level when spatial correlations were removed from the image. This change in reliability was due to a reorganization of between-neuron correlations. Strongly correlated neurons formed ensembles that reliably and accurately encoded visual stimuli, whereas reducing spatial correlations reduced the activation of these ensembles, leading to an unreliable code. Together with an ensemble-specific normalization model, these results suggest that the coordinated activation of specific subsets of neurons underlies the reliable coding of natural scenes. SIGNIFICANCE STATEMENT The natural environment is rich with information. To process this information with high fidelity, V1 neurons have to be robust to noise and, consequentially, must generate responses that are reliable from trial to trial. While several studies have hinted that both stimulus attributes and population coding may reduce noise, the details remain unclear. Specifically, what features of natural scenes are important and how do they modulate reliability? This study is the first to investigate the role of spatial correlations, which are a fundamental attribute of natural scenes, in shaping stimulus coding by V1 neurons. Our results provide new insights into how stimulus spatial correlations reorganize the correlated activation of specific ensembles of neurons to ensure accurate information processing in V1. PMID:26511254

  11. Design and validation of an automated hydrostatic weighing system.

    PubMed

    McClenaghan, B A; Rocchio, L

    1986-08-01

    The purpose of this study was to design and evaluate the validity of an automated technique to assess body density using a computerized hydrostatic weighing system. An existing hydrostatic tank was modified and interfaced with a microcomputer equipped with an analog-to-digital converter. Software was designed to input variables, control the collection of data, calculate selected measurements, and provide a summary of the results of each session. Validity of the data obtained utilizing the automated hydrostatic weighing system was estimated by: evaluating the reliability of the transducer/computer interface to measure objects of known underwater weight; comparing the data against a criterion measure; and determining inter-session subject reliability. Values obtained from the automated system were found to be highly correlated with known underwater weights (r = 0.99, SEE = 0.0060 kg). Data concurrently obtained utilizing the automated system and a manual chart recorder were also found to be highly correlated (r = 0.99, SEE = 0.0606 kg). Inter-session subject reliability was determined utilizing data collected on subjects (N = 16) tested on two occasions approximately 24 h apart. Correlations revealed high relationships between measures of underwater weight (r = 0.99, SEE = 0.1399 kg) and body density (r = 0.98, SEE = 0.00244 g X cm-1). Results indicate that a computerized hydrostatic weighing system is a valid and reliable method for determining underwater weight.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Jay Tillay

    For three years, Sandia National Laboratories, Georgia Institute of Technology, and University of Illinois at Urbana-Champaign investigated a smart grid vision in which renewable-centric Virtual Power Plants (VPPs) provided ancillary services with interoperable distributed energy resources (DER). This team researched, designed, built, and evaluated real-time VPP designs incorporating DER forecasting, stochastic optimization, controls, and cyber security to construct a system capable of delivering reliable ancillary services, which have been traditionally provided by large power plants or other dedicated equipment. VPPs have become possible through an evolving landscape of state and national interconnection standards, which now require DER to include grid-supportmore » functionality and communications capabilities. This makes it possible for third party aggregators to provide a range of critical grid services such as voltage regulation, frequency regulation, and contingency reserves to grid operators. This paradigm (a) enables renewable energy, demand response, and energy storage to participate in grid operations and provide grid services, (b) improves grid reliability by providing additional operating reserves for utilities, independent system operators (ISOs), and regional transmission organization (RTOs), and (c) removes renewable energy high-penetration barriers by providing services with photovoltaics and wind resources that traditionally were the jobs of thermal generators. Therefore, it is believed VPP deployment will have far-reaching positive consequences for grid operations and may provide a robust pathway to high penetrations of renewables on US power systems. In this report, we design VPPs to provide a range of grid-support services and demonstrate one VPP which simultaneously provides bulk-system energy and ancillary reserves.« less

  13. Reliability of recurrence quantification analysis measures of the center of pressure during standing in individuals with musculoskeletal disorders.

    PubMed

    Mazaheri, Masood; Negahban, Hossein; Salavati, Mahyar; Sanjari, Mohammad Ali; Parnianpour, Mohamad

    2010-09-01

    Although the application of nonlinear tools including recurrence quantification analysis (RQA) has increasingly grown in the recent years especially in balance-disordered populations, there have been few studies which determine their measurement properties. Therefore, a methodological study was performed to estimate the intersession and intrasession reliability of some dynamic features provided by RQA for nonlinear analysis of center of pressure (COP) signals recorded during quiet standing in a sample of patients with musculoskeletal disorders (MSDs) including low back pain (LBP), anterior cruciate ligament (ACL) injury and functional ankle instability (FAI). The subjects completed postural measurements with three levels of difficulty (rigid surface-eyes open, rigid surface-eyes closed, and foam surface-eyes closed). Four RQA measures (% recurrence, % determinism, entropy, and trend) were extracted from the recurrence plot. Relative reliability of these measures was assessed using intraclass correlation coefficient and absolute reliability using standard error of measurement and coefficient of variation. % Determinism and entropy were the most reliable features of RQA for the both intersession and intrasession reliability measures. High level of reliability of % determinism and entropy in this preliminary investigation may show their clinical promise for discriminative and evaluative purposes of balance performance. 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

  14. Reliability of Eustachian tube function measurements in a hypobaric and hyperbaric pressure chamber.

    PubMed

    Meyer, M F; Jansen, S; Mordkovich, O; Hüttenbrink, K-B; Beutner, D

    2017-12-01

    Measurement of the Eustachian tube (ET) function is a challenge. The demand for a precise and meaningful diagnostic tool increases-especially because more and more operative therapies are being offered without objective evidence. The measurement of the ET function by continuous impedance recording in a pressure chamber is an established method, although the reliability of the measurements is still unclear. Twenty-five participants (50 ears) were exposed to phases of compression and decompression in a hypo- and hyperbaric pressure chamber. The ET function reflecting parameters-ET opening pressure (ETOP), ET opening duration (ETOD) and ET opening frequency (ETOF)-were determined under exactly the same preconditions three times in a row. The intraclass correlation coefficient (ICC) and Bland and Altman plot were used to assess test-retest reliability. ICCs revealed a high correlation for ETOP and ETOF in phases of decompression (passive equalisation) as well as ETOD and ETOP in phases of compression (active induced equalisation). Very high correlation could be shown for ETOD in decompression and ETOF in compression phases. The Bland and Altman graphs could show that measurements provide results within a 95 % confidence interval in compression and decompression phases. We conclude that measurements in a pressure chamber are a very valuable tool in terms of estimating the ET opening and closing function. Measurements show some variance comparing participants, but provide reliable results within a 95 % confidence interval in retest. This study is the basis for enabling efficacy measurements of ET treatment modalities. © 2017 John Wiley & Sons Ltd.

  15. Evaluating the application of multi-satellite observation in hydrologic modeling

    USDA-ARS?s Scientific Manuscript database

    When monitoring local or regional hydrosphere dynamics for applications such as agricultural productivity or drought and flooding events, it is necessary to have accurate, high-resolution estimates of terrestrial water and energy storages. Though in-situ observations provide reliable estimates of hy...

  16. Sensing system development for HOV/HOT (high occupancy vehicle) lane monitoring.

    DOT National Transportation Integrated Search

    2011-02-01

    With continued interest in the efficient use of roadways the ability to monitor the use of HOV/HOT lanes is essential for management, planning and operation. A system to reliably monitor these lanes on a continuous basis and provide usage statistics ...

  17. 36 CFR 219.11 - Monitoring and evaluation for adaptive management.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... viability is high and population characteristics cannot be reliably inferred from ecological conditions. The...) Monitoring and evaluation of social and economic sustainability. The plan monitoring strategy for the monitoring and evaluation of social and economic sustainability should provide for periodic review of...

  18. A compact magnetic bearing for gimballed momentum wheel

    NASA Technical Reports Server (NTRS)

    Yabu-Uchi, K.; Inoue, M.; Akishita, S.; Murakami, C.; Okamoto, O.

    1983-01-01

    A three axis controlled magnetic bearing and its application to a momentum wheel are described. The four divided stators provide a momentum wheel with high reliability, low weight, large angular momentum storage capacity, and gimbal control. Those characteristics are desirable for spacecraft attitude control.

  19. Incorporating Primary Scientific Literature in Middle and High School Education.

    PubMed

    Fankhauser, Sarah C; Lijek, Rebeccah S

    2016-03-01

    Primary literature is the most reliable and direct source of scientific information, but most middle school and high school science is taught using secondary and tertiary sources. One reason for this is that primary science articles can be difficult to access and interpret for young students and for their teachers, who may lack exposure to this type of writing. The Journal of Emerging Investigators (JEI) was created to fill this gap and provide primary research articles that can be accessed and read by students and their teachers. JEI is a non-profit, online, open-access, peer-reviewed science journal dedicated to mentoring and publishing the scientific research of middle and high school students. JEI articles provide reliable scientific information that is written by students and therefore at a level that their peers can understand. For student-authors who publish in JEI, the review process and the interaction with scientists provide invaluable insight into the scientific process. Moreover, the resulting repository of free, student-written articles allows teachers to incorporate age-appropriate primary literature into the middle and high school science classroom. JEI articles can be used for teaching specific scientific content or for teaching the process of the scientific method itself. The critical thinking skills that students learn by engaging with the primary literature will be invaluable for the development of a scientifically-literate public.

  20. Incorporating Primary Scientific Literature in Middle and High School Education†

    PubMed Central

    Fankhauser, Sarah C.; Lijek, Rebeccah S.

    2016-01-01

    Primary literature is the most reliable and direct source of scientific information, but most middle school and high school science is taught using secondary and tertiary sources. One reason for this is that primary science articles can be difficult to access and interpret for young students and for their teachers, who may lack exposure to this type of writing. The Journal of Emerging Investigators (JEI) was created to fill this gap and provide primary research articles that can be accessed and read by students and their teachers. JEI is a non-profit, online, open-access, peer-reviewed science journal dedicated to mentoring and publishing the scientific research of middle and high school students. JEI articles provide reliable scientific information that is written by students and therefore at a level that their peers can understand. For student-authors who publish in JEI, the review process and the interaction with scientists provide invaluable insight into the scientific process. Moreover, the resulting repository of free, student-written articles allows teachers to incorporate age-appropriate primary literature into the middle and high school science classroom. JEI articles can be used for teaching specific scientific content or for teaching the process of the scientific method itself. The critical thinking skills that students learn by engaging with the primary literature will be invaluable for the development of a scientifically-literate public. PMID:27047607

  1. AIRNET: A real-time comunications network for aircraft

    NASA Technical Reports Server (NTRS)

    Weaver, Alfred C.; Cain, Brendan G.; Colvin, M. Alexander; Simoncic, Robert

    1990-01-01

    A real-time local area network was developed for use on aircraft and space vehicles. It uses token ring technology to provide high throughput, low latency, and high reliability. The system was implemented on PCs and PC/ATs operating on PCbus, and on Intel 8086/186/286/386s operating on Multibus. A standard IEEE 802.2 logical link control interface was provided to (optional) upper layer software; this permits the controls designer to utilize standard communications protocols (e.g., ISO, TCP/IP) if time permits, or to utilize a very fast link level protocol directly if speed is critical. Both unacknowledged datagram and reliable virtual circuit services are supported. A station operating an 8 MHz Intel 286 as a host can generate a sustained load of 1.8 megabits per second per station, and a 100-byte message can be delivered from the transmitter's user memory to the receiver's user memory, including all operating system and network overhead, in under 4 milliseconds.

  2. Modeling and Verification of Dependable Electronic Power System Architecture

    NASA Astrophysics Data System (ADS)

    Yuan, Ling; Fan, Ping; Zhang, Xiao-fang

    The electronic power system can be viewed as a system composed of a set of concurrently interacting subsystems to generate, transmit, and distribute electric power. The complex interaction among sub-systems makes the design of electronic power system complicated. Furthermore, in order to guarantee the safe generation and distribution of electronic power, the fault tolerant mechanisms are incorporated in the system design to satisfy high reliability requirements. As a result, the incorporation makes the design of such system more complicated. We propose a dependable electronic power system architecture, which can provide a generic framework to guide the development of electronic power system to ease the development complexity. In order to provide common idioms and patterns to the system *designers, we formally model the electronic power system architecture by using the PVS formal language. Based on the PVS model of this system architecture, we formally verify the fault tolerant properties of the system architecture by using the PVS theorem prover, which can guarantee that the system architecture can satisfy high reliability requirements.

  3. Reliability and cost evaluation of small isolated power systems containing photovoltaic and wind energy

    NASA Astrophysics Data System (ADS)

    Karki, Rajesh

    Renewable energy application in electric power systems is growing rapidly worldwide due to enhanced public concerns for adverse environmental impacts and escalation in energy costs associated with the use of conventional energy sources. Photovoltaics and wind energy sources are being increasingly recognized as cost effective generation sources. A comprehensive evaluation of reliability and cost is required to analyze the actual benefits of utilizing these energy sources. The reliability aspects of utilizing renewable energy sources have largely been ignored in the past due the relatively insignificant contribution of these sources in major power systems, and consequently due to the lack of appropriate techniques. Renewable energy sources have the potential to play a significant role in the electrical energy requirements of small isolated power systems which are primarily supplied by costly diesel fuel. A relatively high renewable energy penetration can significantly reduce the system fuel costs but can also have considerable impact on the system reliability. Small isolated systems routinely plan their generating facilities using deterministic adequacy methods that cannot incorporate the highly erratic behavior of renewable energy sources. The utilization of a single probabilistic risk index has not been generally accepted in small isolated system evaluation despite its utilization in most large power utilities. Deterministic and probabilistic techniques are combined in this thesis using a system well-being approach to provide useful adequacy indices for small isolated systems that include renewable energy. This thesis presents an evaluation model for small isolated systems containing renewable energy sources by integrating simulation models that generate appropriate atmospheric data, evaluate chronological renewable power outputs and combine total available energy and load to provide useful system indices. A software tool SIPSREL+ has been developed which generates risk, well-being and energy based indices to provide realistic cost/reliability measures of utilizing renewable energy. The concepts presented and the examples illustrated in this thesis will help system planners to decide on appropriate installation sites, the types and mix of different energy generating sources, the optimum operating policies, and the optimum generation expansion plans required to meet increasing load demands in small isolated power systems containing photovoltaic and wind energy sources.

  4. Assessment of physical server reliability in multi cloud computing system

    NASA Astrophysics Data System (ADS)

    Kalyani, B. J. D.; Rao, Kolasani Ramchand H.

    2018-04-01

    Business organizations nowadays functioning with more than one cloud provider. By spreading cloud deployment across multiple service providers, it creates space for competitive prices that minimize the burden on enterprises spending budget. To assess the software reliability of multi cloud application layered software reliability assessment paradigm is considered with three levels of abstractions application layer, virtualization layer, and server layer. The reliability of each layer is assessed separately and is combined to get the reliability of multi-cloud computing application. In this paper, we focused on how to assess the reliability of server layer with required algorithms and explore the steps in the assessment of server reliability.

  5. Photonic elements in smart systems for use in aerospace platforms

    NASA Astrophysics Data System (ADS)

    Adamovsky, Grigory; Baumbick, Robert J.; Tabib-Azar, Massood

    1998-07-01

    To compete globally in the next millennium, designers of new transportation vehicles will have to be innovative. Keen competition will reward innovative concepts that are developed and proven first. In order to improve reliability of aerospace platforms and reduce operating cots, new technologies must be exploited to produce autonomous systems, based on highly distributed, smart systems, which can be treated as line replaceable units. These technologies include photonics, which provide sensing and information transfer functions, and micro electro mechanical systems that will produce the actuation and, in some cases, may even provide a computing capability that resembles the hydro- mechanical control system used in older aircraft systems. The combination of these technologies will provide unique systems that will enable achieving the reliability and cost goals dictated by global market. In the article we review some of these issues and discuss a role of photonics in smart system for aerospace platforms.

  6. The multiple sclerosis work difficulties questionnaire: translation and cross-cultural adaptation to Turkish and assessment of validity and reliability.

    PubMed

    Kahraman, Turhan; Özdoğar, Asiye Tuba; Honan, Cynthia Alison; Ertekin, Özge; Özakbaş, Serkan

    2018-05-09

    To linguistically and culturally adapt the Multiple Sclerosis Work Difficulties Questionnaire-23 (MSWDQ-23) for use in Turkey, and to examine its reliability and validity. Following standard forward-back translation of the MSWDQ-23, it was administered to 124 people with multiple sclerosis (MS). Validity was evaluated using related outcome measures including those related to employment status and expectations, disability level, fatigue, walking, and quality of life. Randomly selected participants were asked to complete the MSWDQ-23 again to assess test-retest reliability. Confirmatory factor analysis on the MSWDQ-23 demonstrated a good fit for the data, and the internal consistency of each subscale was excellent. The test-retest reliability for the total score, psychological/cognitive barriers, physical barriers, and external barriers subscales were high. The MSWDQ-23 and its subscales were positively correlated with the employment, disability level, walking, and fatigue outcome measures. This study suggests that the Turkish version of MSWDQ-23 has high reliability and adequate validity, and it can be used to determine the difficulties faced by people with multiple sclerosis in workplace. Moreover, the study provides evidence about the test-retest reliability of the questionnaire. Implications for rehabilitation Multiple sclerosis affects young people of working age. Understanding work-related problems is crucial to enhance people with multiple sclerosis likelihood of maintaining their job. The Multiple Sclerosis Work Difficulties Questionnaire-23 (MSWDQ-23) is a valid and reliable measure of perceived workplace difficulties in people with multiple sclerosis: we presented its validation to Turkish. Professionals working in the field of vocational rehabilitation may benefit from using the MSWDQ-23 to predict the current work outcomes and future employment expectations.

  7. The reliability of nonlinear least-squares algorithm for data analysis of neural response activity during sinusoidal rotational stimulation in semicircular canal neurons.

    PubMed

    Ren, Pengyu; Li, Bowen; Dong, Shiyao; Chen, Lin; Zhang, Yuelin

    2018-01-01

    Although many mathematical methods were used to analyze the neural activity under sinusoidal stimulation within linear response range in vestibular system, the reliabilities of these methods are still not reported, especially in nonlinear response range. Here we chose nonlinear least-squares algorithm (NLSA) with sinusoidal model to analyze the neural response of semicircular canal neurons (SCNs) during sinusoidal rotational stimulation (SRS) over a nonlinear response range. Our aim was to acquire a reliable mathematical method for data analysis under SRS in vestibular system. Our data indicated that the reliability of this method in an entire SCNs population was quite satisfactory. However, the reliability was strongly negatively depended on the neural discharge regularity. In addition, stimulation parameters were the vital impact factors influencing the reliability. The frequency had a significant negative effect but the amplitude had a conspicuous positive effect on the reliability. Thus, NLSA with sinusoidal model resulted a reliable mathematical tool for data analysis of neural response activity under SRS in vestibular system and more suitable for those under the stimulation with low frequency but high amplitude, suggesting that this method can be used in nonlinear response range. This method broke out of the restriction of neural activity analysis under nonlinear response range and provided a solid foundation for future study in nonlinear response range in vestibular system.

  8. The reliability of nonlinear least-squares algorithm for data analysis of neural response activity during sinusoidal rotational stimulation in semicircular canal neurons

    PubMed Central

    Li, Bowen; Dong, Shiyao; Chen, Lin; Zhang, Yuelin

    2018-01-01

    Although many mathematical methods were used to analyze the neural activity under sinusoidal stimulation within linear response range in vestibular system, the reliabilities of these methods are still not reported, especially in nonlinear response range. Here we chose nonlinear least-squares algorithm (NLSA) with sinusoidal model to analyze the neural response of semicircular canal neurons (SCNs) during sinusoidal rotational stimulation (SRS) over a nonlinear response range. Our aim was to acquire a reliable mathematical method for data analysis under SRS in vestibular system. Our data indicated that the reliability of this method in an entire SCNs population was quite satisfactory. However, the reliability was strongly negatively depended on the neural discharge regularity. In addition, stimulation parameters were the vital impact factors influencing the reliability. The frequency had a significant negative effect but the amplitude had a conspicuous positive effect on the reliability. Thus, NLSA with sinusoidal model resulted a reliable mathematical tool for data analysis of neural response activity under SRS in vestibular system and more suitable for those under the stimulation with low frequency but high amplitude, suggesting that this method can be used in nonlinear response range. This method broke out of the restriction of neural activity analysis under nonlinear response range and provided a solid foundation for future study in nonlinear response range in vestibular system. PMID:29304173

  9. MASH Suite: a user-friendly and versatile software interface for high-resolution mass spectrometry data interpretation and visualization.

    PubMed

    Guner, Huseyin; Close, Patrick L; Cai, Wenxuan; Zhang, Han; Peng, Ying; Gregorich, Zachery R; Ge, Ying

    2014-03-01

    The rapid advancements in mass spectrometry (MS) instrumentation, particularly in Fourier transform (FT) MS, have made the acquisition of high-resolution and high-accuracy mass measurements routine. However, the software tools for the interpretation of high-resolution MS data are underdeveloped. Although several algorithms for the automatic processing of high-resolution MS data are available, there is still an urgent need for a user-friendly interface with functions that allow users to visualize and validate the computational output. Therefore, we have developed MASH Suite, a user-friendly and versatile software interface for processing high-resolution MS data. MASH Suite contains a wide range of features that allow users to easily navigate through data analysis, visualize complex high-resolution MS data, and manually validate automatically processed results. Furthermore, it provides easy, fast, and reliable interpretation of top-down, middle-down, and bottom-up MS data. MASH Suite is convenient, easily operated, and freely available. It can greatly facilitate the comprehensive interpretation and validation of high-resolution MS data with high accuracy and reliability.

  10. HDMR methods to assess reliability in slope stability analyses

    NASA Astrophysics Data System (ADS)

    Kozubal, Janusz; Pula, Wojciech; Vessia, Giovanna

    2014-05-01

    Stability analyses of complex rock-soil deposits shall be tackled considering the complex structure of discontinuities within rock mass and embedded soil layers. These materials are characterized by a high variability in physical and mechanical properties. Thus, to calculate the slope safety factor in stability analyses two issues must be taken into account: 1) the uncertainties related to structural setting of the rock-slope mass and 2) the variability in mechanical properties of soils and rocks. High Dimensional Model Representation (HDMR) (Chowdhury et al. 2009; Chowdhury and Rao 2010) can be used to carry out the reliability index within complex rock-soil slopes when numerous random variables with high coefficient of variations are considered. HDMR implements the inverse reliability analysis, meaning that the unknown design parameters are sought provided that prescribed reliability index values are attained. Such approach uses implicit response functions according to the Response Surface Method (RSM). The simple RSM can be efficiently applied when less than four random variables are considered; as the number of variables increases, the efficiency in reliability index estimation decreases due to the great amount of calculations. Therefore, HDMR method is used to improve the computational accuracy. In this study, the sliding mechanism in Polish Flysch Carpathian Mountains have been studied by means of HDMR. The Southern part of Poland where Carpathian Mountains are placed is characterized by a rather complicated sedimentary pattern of flysh rocky-soil deposits that can be simplified into three main categories: (1) normal flysch, consisting of adjacent sandstone and shale beds of approximately equal thickness, (2) shale flysch, where shale beds are thicker than adjacent sandstone beds, and (3) sandstone flysch, where the opposite holds. Landslides occur in all flysch deposit types thus some configurations of possible unstable settings (within fractured rocky-soil masses) resulting in sliding mechanisms have been investigated in this study. The reliability indices values drawn from the HDRM method have been compared with conventional approaches as neural networks: the efficiency of HDRM is shown in the case studied. References Chowdhury R., Rao B.N. and Prasad A.M. 2009. High-dimensional model representation for structural reliability analysis. Commun. Numer. Meth. Engng, 25: 301-337. Chowdhury R. and Rao B. 2010. Probabilistic Stability Assessment of Slopes Using High Dimensional Model Representation. Computers and Geotechnics, 37: 876-884.

  11. Development and Validation of the User Version of the Mobile Application Rating Scale (uMARS).

    PubMed

    Stoyanov, Stoyan R; Hides, Leanne; Kavanagh, David J; Wilson, Hollie

    2016-06-10

    The Mobile Application Rating Scale (MARS) provides a reliable method to assess the quality of mobile health (mHealth) apps. However, training and expertise in mHealth and the relevant health field is required to administer it. This study describes the development and reliability testing of an end-user version of the MARS (uMARS). The MARS was simplified and piloted with 13 young people to create the uMARS. The internal consistency and test-retest reliability of the uMARS was then examined in a second sample of 164 young people participating in a randomized controlled trial of a mHealth app. App ratings were collected using the uMARS at 1-, 3,- and 6-month follow up. The uMARS had excellent internal consistency (alpha = .90), with high individual alphas for all subscales. The total score and subscales had good test-retest reliability over both 1-2 months and 3 months. The uMARS is a simple tool that can be reliably used by end-users to assess the quality of mHealth apps.

  12. SIERRA - A 3-D device simulator for reliability modeling

    NASA Astrophysics Data System (ADS)

    Chern, Jue-Hsien; Arledge, Lawrence A., Jr.; Yang, Ping; Maeda, John T.

    1989-05-01

    SIERRA is a three-dimensional general-purpose semiconductor-device simulation program which serves as a foundation for investigating integrated-circuit (IC) device and reliability issues. This program solves the Poisson and continuity equations in silicon under dc, transient, and small-signal conditions. Executing on a vector/parallel minisupercomputer, SIERRA utilizes a matrix solver which uses an incomplete LU (ILU) preconditioned conjugate gradient square (CGS, BCG) method. The ILU-CGS method provides a good compromise between memory size and convergence rate. The authors have observed a 5x to 7x speedup over standard direct methods in simulations of transient problems containing highly coupled Poisson and continuity equations such as those found in reliability-oriented simulations. The application of SIERRA to parasitic CMOS latchup and dynamic random-access memory single-event-upset studies is described.

  13. Accounting for Proof Test Data in a Reliability Based Design Optimization Framework

    NASA Technical Reports Server (NTRS)

    Ventor, Gerharad; Scotti, Stephen J.

    2012-01-01

    This paper investigates the use of proof (or acceptance) test data during the reliability based design optimization of structural components. It is assumed that every component will be proof tested and that the component will only enter into service if it passes the proof test. The goal is to reduce the component weight, while maintaining high reliability, by exploiting the proof test results during the design process. The proposed procedure results in the simultaneous design of the structural component and the proof test itself and provides the designer with direct control over the probability of failing the proof test. The procedure is illustrated using two analytical example problems and the results indicate that significant weight savings are possible when exploiting the proof test results during the design process.

  14. SAFT nickel hydrogen cell cycling status

    NASA Technical Reports Server (NTRS)

    Borthomieu, Yannick; Duquesne, Didier

    1994-01-01

    An overview of the NiH2 cell development is given. The NiH2 SAFT system is an electrochemical (single or dual) stack (IPV). The stack is mounted in an hydroformed Inconel 718 vessel operating at high pressure, equipped with 'rabbit ears' ceramic brazed electrical feedthroughs. The cell design is described: positive electrode, negative electrode, and stack configuration. Overviews of low earth orbit and geostationary earth orbit cyclings are provided. DPA results are also provided. The cycling and DPA results demonstrate that SAFT NiH2 is characterized by high reliability and very stable performances.

  15. Downhole fiber optic sensing: the oilfield service provider's perspective

    NASA Astrophysics Data System (ADS)

    Skinner, Neal G.; Maida, John L., Jr.

    2004-12-01

    There is increasing interest in the petroleum industry in the application of fiber-optic sensing techniques. In this paper, we review which sensing technologies are being adopted downhole and the drivers for this deployment. We describe the performance expectations (accuracy, resolution, stability and operational lifetime) that the oil companies and the oil service companies have for fiber-optic sensing systems. We also describe the environmental conditions (high hydrostatic pressures, high temperatures, shock, vibration, crush, and chemical attack) that these systems must tolerate in order to provide reliable and economically attractive reservoir-performance monitoring solutions.

  16. The Application of a Residual Risk Evaluation Technique Used for Expendable Launch Vehicles

    NASA Technical Reports Server (NTRS)

    Latimer, John A.

    2009-01-01

    This presentation provides a Residual Risk Evaluation Technique (RRET) developed by Kennedy Space Center (KSC) Safety and Mission Assurance (S&MA) Launch Services Division. This technique is one of many procedures used by S&MA at KSC to evaluate residual risks for each Expendable Launch Vehicle (ELV) mission. RRET is a straight forward technique that incorporates the proven methodology of risk management, fault tree analysis, and reliability prediction. RRET derives a system reliability impact indicator from the system baseline reliability and the system residual risk reliability values. The system reliability impact indicator provides a quantitative measure of the reduction in the system baseline reliability due to the identified residual risks associated with the designated ELV mission. An example is discussed to provide insight into the application of RRET.

  17. Peer-review for selection of oral presentations for conferences: Are we reliable?

    PubMed

    Deveugele, Myriam; Silverman, Jonathan

    2017-11-01

    Although peer-review for journal submission, grant-applications and conference submissions has been called 'a counter- stone of science', and even 'the gold standard for evaluating scientific merit', publications on this topic remain scares. Research that has investigated peer-review reveals several issues and criticisms concerning bias, poor quality review, unreliability and inefficiency. The most important weakness of the peer review process is the inconsistency between reviewers leading to inadequate inter-rater reliability. To report the reliability of ratings for a large international conference and to suggest possible solutions to overcome the problem. In 2016 during the International Conference on Communication in Healthcare, organized by EACH: International Association for Communication in Healthcare, a calibration exercise was proposed and feedback was reported back to the participants of the exercise. Most abstracts, as well as most peer-reviewers, receive and give scores around the median. Contrary to the general assumption that there are high and low scorers, in this group only 3 peer-reviewers could be identified with a high mean, while 7 has a low mean score. Only 2 reviewers gave only high ratings (4 and 5). Of the eight abstracts included in this exercise, only one abstract received a high mean score and one a low mean score. Nevertheless, both these abstracts received both low and high scores; all other abstracts received all possible scores. Peer-review of submissions for conferences are, in accordance with the literature, unreliable. New and creative methods will be needed to give the participants of a conference what they really deserve: a more reliable selection of the best abstracts. More raters per abstract improves the inter-rater reliability; training of reviewers could be helpful; providing feedback to reviewers can lead to less inter-rater disagreement; fostering negative peer-review (rejecting the inappropriate submissions) rather than a positive (accepting the best) could be fruitful for selecting abstracts for conferences. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Usefulness of the Patient Health Questionnaire-9 for Korean medical students.

    PubMed

    Yoon, Seoyoung; Lee, Yunhwan; Han, Changsu; Pae, Chi-Un; Yoon, Ho-Kyoung; Patkar, Ashwin A; Steffens, David C; Kim, Yong-Ku

    2014-12-01

    Depression may be highly prevalent among medical students, lowering their functioning and quality of life. Using appropriate extant depression scales to screen for depression and determining factors associated with depression can be helpful in managing it. This study examines the validity and reliability of the Patient Health Questionnaire-9 (PHQ-9) for medical students and the relationship between their scores and sociodemographic variables. This study surveyed 174 medical students using demographic questionnaires, the PHQ-9, the Beck Depression Inventory (BDI), the Patient Heath Questionnaire-15 (PHQ-15), the Beck Anxiety Inventory (BAI), and the Perceived Stress Scale (PSS). It calculated the Cronbach's α for internal consistency and Pearson's correlation coefficients for test-retest reliability and convergent validity of the PHQ-9. In order to examine the relationship between depression and demographic variables, this study performed independent t tests, one-way analysis of variance, chi-square, and binary logistic regressions. The PHQ-9 was reliable (Cronbach's α = 0.837, test-retest reliability, r = 0.650) and valid (r = 0.509-0.807) when employed with medical students. Total scores on the PHQ-9 were significantly higher among low-perceived academic achievers than among high-perceived academic achievers (p < 0.01). Depression was more prevalent in poor-perceived academic achievers than in high-perceived academic achievers. Similarly, poor-perceived academic achievers were at greater risk of depression than were high-perceived academic achievers (odds ratio [95 % confidence interval] 3.686 [1.092-12.439], p < 0.05). The PHQ-9 has satisfactory reliability and validity in medical students in South Korea. Depression is related to poor-perceived academic achievement when measured with the PHQ-9. Early screening for depression with the PHQ-9 in medical students and providing prompt management to high scorers may not only be beneficial to students' mental health but also improve their academic performance.

  19. Psychometric evaluation of an inpatient consumer survey measuring satisfaction with psychiatric care.

    PubMed

    Ortiz, Glorimar; Schacht, Lucille

    2012-01-01

    Measurement of consumers' satisfaction in psychiatric settings is important because it has been correlated with improved clinical outcomes and administrative measures of high-quality care. These consumer satisfaction measurements are actively used as performance measures required by the accreditation process and for quality improvement activities. Our objectives were (i) to re-evaluate, through exploratory factor analysis (EFA) and confirmatory factor analysis (CFA), the structure of an instrument intended to measure consumers' satisfaction with care in psychiatric settings and (ii) to examine and publish the psychometric characteristics, validity and reliability, of the Inpatient Consumer Survey (ICS). To psychometrically test the structure of the ICS, 34 878 survey results, submitted by 90 psychiatric hospitals in 2008, were extracted from the Behavioral Healthcare Performance Measurement System (BHPMS). Basic descriptive item-response and correlation analyses were performed for total surveys. Two datasets were randomly created for analysis. A random sample of 8229 survey results was used for EFA. Another random sample of 8261 consumer survey results was used for CFA. This same sample was used to perform validity and reliability analyses. The item-response analysis showed that the mean range for a disagree/agree five-point scale was 3.10-3.94. Correlation analysis showed a strong relationship between items. Six domains (dignity, rights, environment, empowerment, participation, and outcome) with internal reliabilities between good to moderate (0.87-0.73) were shown to be related to overall care satisfaction. Overall reliability for the instrument was excellent (0.94). Results from CFA provided support for the domains structure of the ICS proposed through EFA. The overall findings from this study provide evidence that the ICS is a reliable measure of consumer satisfaction in psychiatric inpatient settings. The analysis has shown the ICS to provide valid and reliable results and to focus on the specific concerns of consumers of psychiatric inpatient care. Scores by item indicate that opportunity for improvement exists across healthcare organizations.

  20. The Brighton musculoskeletal Patient-Reported Outcome Measure (BmPROM): An assessment of validity, reliability, and responsiveness.

    PubMed

    Bryant, Elizabeth; Murtagh, Shemane; Finucane, Laura; McCrum, Carol; Mercer, Christopher; Smith, Toby; Canby, Guy; Rowe, David A; Moore, Ann P

    2018-05-11

    In response for the need of a freely available, stand-alone, validated outcome measure for use within musculoskeletal (MSK) physiotherapy practice, sensitive enough to measure clinical effectiveness, we developed an MSK patient reported outcome measure. This study examined the validity and reliability of the newly developed Brighton musculoskeletal Patient-Reported Outcome Measure (BmPROM) within physiotherapy outpatient settings. Two hundred twenty-four patients attending physiotherapy outpatient departments in South East England with an MSK condition participated in this study. The BmPROM was assessed for user friendliness (rated feedback, N = 224), reliability (internal consistency and test-retest reliability, n = 42), validity (internal and external construct validity, N = 224), and responsiveness (internal, n = 25). Exploratory factor analysis indicated that a two-factor model provides a good fit to the data. Factors were representative of "Functionality" and "Wellbeing". Correlations observed between the BmPROM and SF-36 domains provided evidence of convergent validity. Reliability results indicated that both subscales were internally consistent with alphas above the acceptable limits for both "Functionality" (α = .85, 95% CI [.81, .88]) and 'Wellbeing' (α = .80, 95% CI [.75, .84]). Test-retest analyses (n = 42) demonstrated a high degree of reliability between "Functionality" (ICC = .84; 95% CI [.72, .91]) and "Wellbeing" scores (ICC = .84; 95% CI [.72, .91]). Further examination of test-retest reliability through the Bland-Altman analysis demonstrated that the difference between "Functionality" and "Wellbeing" test scores did not vary as a function of absolute test score. Large treatment effect sizes were found for both subscales (Functionality d = 1.10; Wellbeing 1.03). The BmPROM is a reliable and valid outcome measure for use in evaluating physiotherapy treatment of MSK conditions. Copyright © 2018 John Wiley & Sons, Ltd.

  1. Robotic Prostatectomy on the Web: A Cross-Sectional Qualitative Assessment.

    PubMed

    Borgmann, Hendrik; Mager, René; Salem, Johannes; Bründl, Johannes; Kunath, Frank; Thomas, Christian; Haferkamp, Axel; Tsaur, Igor

    2016-08-01

    Many patients diagnosed with prostate cancer search for information on robotic prostatectomy (RobP) on the Web. We aimed to evaluate the qualitative characteristics of the mostly frequented Web sites on RobP with a particular emphasis on provider-dependent issues. Google was searched for the term "robotic prostatectomy" in Europe and North America. The mostly frequented Web sites were selected and classified as physician-provided and publically-provided. Quality was measured using Journal of the American Medical Association (JAMA) benchmark criteria, DISCERN score, and addressing of Trifecta surgical outcomes. Popularity was analyzed using Google PageRank and Alexa tool. Accessibility, usability, and reliability were investigated using the LIDA tool and readability was assessed using readability indices. Twenty-eight Web sites were physician-provided and 15 publically-provided. For all Web sites, 88% of JAMA benchmark criteria were fulfilled, DISCERN quality score was high, and 81% of Trifecta outcome measurements were addressed. Popularity was average according to Google PageRank (mean 2.9 ± 1.5) and Alexa Traffic Rank (median, 49,109; minimum, 7; maximum, 8,582,295). Accessibility (85 ± 7%), usability (92 ± 3%), and reliability scores (88 ± 8%) were moderate to high. Automated Readability Index was 7.2 ± 2.1 and Flesch-Kincaid Grade Level was 9 ± 2, rating the Web sites as difficult to read. Physician-provided Web sites had higher quality scores and lower readability compared with publically-provided Web sites. Websites providing information on RobP obtained medium to high ratings in all domains of quality in the current assessment. In contrast, readability needs to be significantly improved so that this content can become available for the populace. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Performance Enhancement of a High Speed Jet Impingement System for Nonvolatile Residue Removal

    NASA Technical Reports Server (NTRS)

    Klausner, James F.; Mei, Renwei; Near, Steve; Stith, Rex

    1996-01-01

    A high speed jet impingement cleaning facility has been developed to study the effectiveness of the nonvolatile residue removal. The facility includes a high pressure air compressor which charges the k-bottles to supply high pressure air, an air heating section to vary the temperature of the high pressure air, an air-water mixing chamber to meter the water flow and generate small size droplets, and a converging- diverging nozzle to deliver the supersonic air-droplet mixture flow to the cleaning surface. To reliably quantify the cleanliness of the surface, a simple procedure for measurement and calibration is developed to relate the amount of the residue on the surface to the relative change in the reflectivity between a clean surface and the greased surface. This calibration procedure is economical, simple, reliable, and robust. a theoretical framework is developed to provide qualitative guidance for the design of the test and interpretation of the experimental results. The result documented in this report support the theoretical considerations.

  3. Separating Common from Unique Variance Within Emotional Distress: An Examination of Reliability and Relations to Worry.

    PubMed

    Marshall, Andrew J; Evanovich, Emma K; David, Sarah Jo; Mumma, Gregory H

    2018-01-17

    High comorbidity rates among emotional disorders have led researchers to examine transdiagnostic factors that may contribute to shared psychopathology. Bifactor models provide a unique method for examining transdiagnostic variables by modelling the common and unique factors within measures. Previous findings suggest that the bifactor model of the Depression Anxiety and Stress Scale (DASS) may provide a method for examining transdiagnostic factors within emotional disorders. This study aimed to replicate the bifactor model of the DASS, a multidimensional measure of psychological distress, within a US adult sample and provide initial estimates of the reliability of the general and domain-specific factors. Furthermore, this study hypothesized that Worry, a theorized transdiagnostic variable, would show stronger relations to general emotional distress than domain-specific subscales. Confirmatory factor analysis was used to evaluate the bifactor model structure of the DASS in 456 US adult participants (279 females and 177 males, mean age 35.9 years) recruited online. The DASS bifactor model fitted well (CFI = 0.98; RMSEA = 0.05). The General Emotional Distress factor accounted for most of the reliable variance in item scores. Domain-specific subscales accounted for modest portions of reliable variance in items after accounting for the general scale. Finally, structural equation modelling indicated that Worry was strongly predicted by the General Emotional Distress factor. The DASS bifactor model is generalizable to a US community sample and General Emotional Distress, but not domain-specific factors, strongly predict the transdiagnostic variable Worry.

  4. Enhancing recovery rates: lessons from year one of IAPT.

    PubMed

    Gyani, Alex; Shafran, Roz; Layard, Richard; Clark, David M

    2013-09-01

    The English Improving Access to Psychological Therapies (IAPT) initiative aims to make evidence-based psychological therapies for depression and anxiety disorder more widely available in the National Health Service (NHS). 32 IAPT services based on a stepped care model were established in the first year of the programme. We report on the reliable recovery rates achieved by patients treated in the services and identify predictors of recovery at patient level, service level, and as a function of compliance with National Institute of Health and Care Excellence (NICE) Treatment Guidelines. Data from 19,395 patients who were clinical cases at intake, attended at least two sessions, had at least two outcomes scores and had completed their treatment during the period were analysed. Outcome was assessed with the patient health questionnaire depression scale (PHQ-9) and the anxiety scale (GAD-7). Data completeness was high for a routine cohort study. Over 91% of treated patients had paired (pre-post) outcome scores. Overall, 40.3% of patients were reliably recovered at post-treatment, 63.7% showed reliable improvement and 6.6% showed reliable deterioration. Most patients received treatments that were recommended by NICE. When a treatment not recommended by NICE was provided, recovery rates were reduced. Service characteristics that predicted higher reliable recovery rates were: high average number of therapy sessions; higher step-up rates among individuals who started with low intensity treatment; larger services; and a larger proportion of experienced staff. Compliance with the IAPT clinical model is associated with enhanced rates of reliable recovery. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. Characterizing wind power resource reliability in southern Africa

    DOE PAGES

    Fant, Charles; Gunturu, Bhaskar; Schlosser, Adam

    2015-08-29

    Producing electricity from wind is attractive because it provides a clean, low-maintenance power supply. However, wind resource is intermittent on various timescales, thus occasionally introducing large and sudden changes in power supply. A better understanding of this variability can greatly benefit power grid planning. In the following study, wind resource is characterized using metrics that highlight these intermittency issues; therefore identifying areas of high and low wind power reliability in southern Africa and Kenya at different time-scales. After developing a wind speed profile, these metrics are applied at various heights in order to assess the added benefit of raising themore » wind turbine hub. Furthermore, since the interconnection of wind farms can aid in reducing the overall intermittency, the value of interconnecting near-by sites is mapped using two distinct methods. Of the countries in this region, the Republic of South Africa has shown the most interest in wind power investment. For this reason, we focus parts of the study on wind reliability in the country. The study finds that, although mean Wind Power Density is high in South Africa compared to its neighboring countries, wind power resource tends to be less reliable than in other parts of southern Africa—namely central Tanzania. We also find that South Africa’s potential varies over different timescales, with higher reliability in the summer than winter, and higher reliability during the day than at night. This study is concluded by introducing two methods and measures to characterize the value of interconnection, including the use of principal component analysis to identify areas with a common signal.« less

  6. Reliability of smartphone-based gait measurements for quantification of physical activity/inactivity levels.

    PubMed

    Ebara, Takeshi; Azuma, Ryohei; Shoji, Naoto; Matsukawa, Tsuyoshi; Yamada, Yasuyuki; Akiyama, Tomohiro; Kurihara, Takahiro; Yamada, Shota

    2017-11-25

    Objective measurements using built-in smartphone sensors that can measure physical activity/inactivity in daily working life have the potential to provide a new approach to assessing workers' health effects. The aim of this study was to elucidate the characteristics and reliability of built-in step counting sensors on smartphones for development of an easy-to-use objective measurement tool that can be applied in ergonomics or epidemiological research. To evaluate the reliability of step counting sensors embedded in seven major smartphone models, the 6-minute walk test was conducted and the following analyses of sensor precision and accuracy were performed: 1) relationship between actual step count and step count detected by sensors, 2) reliability between smartphones of the same model, and 3) false detection rates when sitting during office work, while riding the subway, and driving. On five of the seven models, the inter-class correlations coefficient (ICC (3,1) ) showed high reliability with a range of 0.956-0.993. The other two models, however, had ranges of 0.443-0.504 and the relative error ratios of the sensor-detected step count to the actual step count were ±48.7%-49.4%. The level of agreement between the same models was ICC (3,1) : 0.992-0.998. The false detection rates differed between the sitting conditions. These results suggest the need for appropriate regulation of step counts measured by sensors, through means such as correction or calibration with a predictive model formula, in order to obtain the highly reliable measurement results that are sought in scientific investigation.

  7. Characterizing wind power resource reliability in southern Africa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fant, Charles; Gunturu, Bhaskar; Schlosser, Adam

    Producing electricity from wind is attractive because it provides a clean, low-maintenance power supply. However, wind resource is intermittent on various timescales, thus occasionally introducing large and sudden changes in power supply. A better understanding of this variability can greatly benefit power grid planning. In the following study, wind resource is characterized using metrics that highlight these intermittency issues; therefore identifying areas of high and low wind power reliability in southern Africa and Kenya at different time-scales. After developing a wind speed profile, these metrics are applied at various heights in order to assess the added benefit of raising themore » wind turbine hub. Furthermore, since the interconnection of wind farms can aid in reducing the overall intermittency, the value of interconnecting near-by sites is mapped using two distinct methods. Of the countries in this region, the Republic of South Africa has shown the most interest in wind power investment. For this reason, we focus parts of the study on wind reliability in the country. The study finds that, although mean Wind Power Density is high in South Africa compared to its neighboring countries, wind power resource tends to be less reliable than in other parts of southern Africa—namely central Tanzania. We also find that South Africa’s potential varies over different timescales, with higher reliability in the summer than winter, and higher reliability during the day than at night. This study is concluded by introducing two methods and measures to characterize the value of interconnection, including the use of principal component analysis to identify areas with a common signal.« less

  8. Behaviour change counselling--how do I know if I am doing it well? The development of the Behaviour Change Counselling Scale (BCCS).

    PubMed

    Vallis, Michael

    2013-02-01

    The purpose of this article is to operationalize behaviour change counselling skills (motivation enhancement, behaviour modification, emotion management) that facilitate self-management support activities and evaluate the psychometric properties of an expert rater scale, the Behaviour Change Counselling Scale (BCCS). Twenty-one healthcare providers with varying levels of behaviour change counselling training interviewed a simulated patient. Videotapes were independently rated by 3 experts on 2 occasions over 6 months. Data on item/subscale characteristics, interrater and test-retest reliability, preliminary data on construct reliability, were reported. All items of the BCCS performed well with the exception of 3 that were dropped due to infrequent endorsement. Most subscales showed strong psychometric properties. Interrater and test-retest reliability coefficients were uniformly high. Competency scores improved significantly from pre- to posttraining. Behaviour change counselling skills to guide lifestyle interventions can be operationalized and assessed in a reliable and valid manner. The BCCS can be used to guide clinical training in lifestyle counselling by operationalizing the component skills and providing feedback on skill achieved. Further research is needed to establish cut scores for competency and scale construct and criterion validity. Copyright © 2013 Canadian Diabetes Association. Published by Elsevier Inc. All rights reserved.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kisner, R.; Melin, A.; Burress, T.

    The objective of this project is to demonstrate improved reliability and increased performance made possible by deeply embedding instrumentation and controls (I&C) in nuclear power plant (NPP) components and systems. The project is employing a highly instrumented canned rotor, magnetic bearing, fluoride salt pump as its I&C technology demonstration platform. I&C is intimately part of the basic millisecond-by-millisecond functioning of the system; treating I&C as an integral part of the system design is innovative and will allow significant improvement in capabilities and performance. As systems become more complex and greater performance is required, traditional I&C design techniques become inadequate andmore » more advanced I&C needs to be applied. New I&C techniques enable optimal and reliable performance and tolerance of noise and uncertainties in the system rather than merely monitoring quasistable performance. Traditionally, I&C has been incorporated in NPP components after the design is nearly complete; adequate performance was obtained through over-design. By incorporating I&C at the beginning of the design phase, the control system can provide superior performance and reliability and enable designs that are otherwise impossible. This report describes the progress and status of the project and provides a conceptual design overview for the platform to demonstrate the performance and reliability improvements enabled by advanced embedded I&C.« less

  10. High-Reliability Health Care: Getting There from Here

    PubMed Central

    Chassin, Mark R; Loeb, Jerod M

    2013-01-01

    Context Despite serious and widespread efforts to improve the quality of health care, many patients still suffer preventable harm every day. Hospitals find improvement difficult to sustain, and they suffer “project fatigue” because so many problems need attention. No hospitals or health systems have achieved consistent excellence throughout their institutions. High-reliability science is the study of organizations in industries like commercial aviation and nuclear power that operate under hazardous conditions while maintaining safety levels that are far better than those of health care. Adapting and applying the lessons of this science to health care offer the promise of enabling hospitals to reach levels of quality and safety that are comparable to those of the best high-reliability organizations. Methods We combined the Joint Commission's knowledge of health care organizations with knowledge from the published literature and from experts in high-reliability industries and leading safety scholars outside health care. We developed a conceptual and practical framework for assessing hospitals’ readiness for and progress toward high reliability. By iterative testing with hospital leaders, we refined the framework and, for each of its fourteen components, defined stages of maturity through which we believe hospitals must pass to reach high reliability. Findings We discovered that the ways that high-reliability organizations generate and maintain high levels of safety cannot be directly applied to today's hospitals. We defined a series of incremental changes that hospitals should undertake to progress toward high reliability. These changes involve the leadership's commitment to achieving zero patient harm, a fully functional culture of safety throughout the organization, and the widespread deployment of highly effective process improvement tools. Conclusions Hospitals can make substantial progress toward high reliability by undertaking several specific organizational change initiatives. Further research and practical experience will be necessary to determine the validity and effectiveness of this framework for high-reliability health care. PMID:24028696

  11. High-reliability health care: getting there from here.

    PubMed

    Chassin, Mark R; Loeb, Jerod M

    2013-09-01

    Despite serious and widespread efforts to improve the quality of health care, many patients still suffer preventable harm every day. Hospitals find improvement difficult to sustain, and they suffer "project fatigue" because so many problems need attention. No hospitals or health systems have achieved consistent excellence throughout their institutions. High-reliability science is the study of organizations in industries like commercial aviation and nuclear power that operate under hazardous conditions while maintaining safety levels that are far better than those of health care. Adapting and applying the lessons of this science to health care offer the promise of enabling hospitals to reach levels of quality and safety that are comparable to those of the best high-reliability organizations. We combined the Joint Commission's knowledge of health care organizations with knowledge from the published literature and from experts in high-reliability industries and leading safety scholars outside health care. We developed a conceptual and practical framework for assessing hospitals' readiness for and progress toward high reliability. By iterative testing with hospital leaders, we refined the framework and, for each of its fourteen components, defined stages of maturity through which we believe hospitals must pass to reach high reliability. We discovered that the ways that high-reliability organizations generate and maintain high levels of safety cannot be directly applied to today's hospitals. We defined a series of incremental changes that hospitals should undertake to progress toward high reliability. These changes involve the leadership's commitment to achieving zero patient harm, a fully functional culture of safety throughout the organization, and the widespread deployment of highly effective process improvement tools. Hospitals can make substantial progress toward high reliability by undertaking several specific organizational change initiatives. Further research and practical experience will be necessary to determine the validity and effectiveness of this framework for high-reliability health care. © 2013 The Authors. The Milbank Quarterly published by Wiley Periodicals Inc. on behalf of Milbank Memorial Fund.

  12. Perform qualify reliability-power tests by shooting common mistakes: practical problems and standard answers per Telcordia/Bellcore requests

    NASA Astrophysics Data System (ADS)

    Yu, Zheng

    2002-08-01

    Facing the new demands of the optical fiber communications market, almost all the performance and reliability of optical network system are dependent on the qualification of the fiber optics components. So, how to comply with the system requirements, the Telcordia / Bellcore reliability and high-power testing has become the key issue for the fiber optics components manufacturers. The qualification of Telcordia / Bellcore reliability or high-power testing is a crucial issue for the manufacturers. It is relating to who is the outstanding one in the intense competition market. These testing also need maintenances and optimizations. Now, work on the reliability and high-power testing have become the new demands in the market. The way is needed to get the 'Triple-Win' goal expected by the component-makers, the reliability-testers and the system-users. To those who are meeting practical problems for the testing, there are following seven topics that deal with how to shoot the common mistakes to perform qualify reliability and high-power testing: ¸ Qualification maintenance requirements for the reliability testing ¸ Lots control for preparing the reliability testing ¸ Sampling select per the reliability testing ¸ Interim measurements during the reliability testing ¸ Basic referencing factors relating to the high-power testing ¸ Necessity of re-qualification testing for the changing of producing ¸ Understanding the similarity for product family by the definitions

  13. Probabilistic Assessment of High-Throughput Wireless Sensor Networks

    PubMed Central

    Kim, Robin E.; Mechitov, Kirill; Sim, Sung-Han; Spencer, Billie F.; Song, Junho

    2016-01-01

    Structural health monitoring (SHM) using wireless smart sensors (WSS) has the potential to provide rich information on the state of a structure. However, because of their distributed nature, maintaining highly robust and reliable networks can be challenging. Assessing WSS network communication quality before and after finalizing a deployment is critical to achieve a successful WSS network for SHM purposes. Early studies on WSS network reliability mostly used temporal signal indicators, composed of a smaller number of packets, to assess the network reliability. However, because the WSS networks for SHM purpose often require high data throughput, i.e., a larger number of packets are delivered within the communication, such an approach is not sufficient. Instead, in this study, a model that can assess, probabilistically, the long-term performance of the network is proposed. The proposed model is based on readily-available measured data sets that represent communication quality during high-throughput data transfer. Then, an empirical limit-state function is determined, which is further used to estimate the probability of network communication failure. Monte Carlo simulation is adopted in this paper and applied to a small and a full-bridge wireless networks. By performing the proposed analysis in complex sensor networks, an optimized sensor topology can be achieved. PMID:27258270

  14. Factors Influencing the Reliability of the Glasgow Coma Scale: A Systematic Review.

    PubMed

    Reith, Florence Cm; Synnot, Anneliese; van den Brande, Ruben; Gruen, Russell L; Maas, Andrew Ir

    2017-06-01

    The Glasgow Coma Scale (GCS) characterizes patients with diminished consciousness. In a recent systematic review, we found overall adequate reliability across different clinical settings, but reliability estimates varied considerably between studies, and methodological quality of studies was overall poor. Identifying and understanding factors that can affect its reliability is important, in order to promote high standards for clinical use of the GCS. The aim of this systematic review was to identify factors that influence reliability and to provide an evidence base for promoting consistent and reliable application of the GCS. A comprehensive literature search was undertaken in MEDLINE, EMBASE, and CINAHL from 1974 to July 2016. Studies assessing the reliability of the GCS in adults or describing any factor that influences reliability were included. Two reviewers independently screened citations, selected full texts, and undertook data extraction and critical appraisal. Methodological quality of studies was evaluated with the consensus-based standards for the selection of health measurement instruments checklist. Data were synthesized narratively and presented in tables. Forty-one studies were included for analysis. Factors identified that may influence reliability are education and training, the level of consciousness, and type of stimuli used. Conflicting results were found for experience of the observer, the pathology causing the reduced consciousness, and intubation/sedation. No clear influence was found for the professional background of observers. Reliability of the GCS is influenced by multiple factors and as such is context dependent. This review points to the potential for improvement from training and education and standardization of assessment methods, for which recommendations are presented. Copyright © 2017 by the Congress of Neurological Surgeons.

  15. Modified personal interviews: resurrecting reliable personal interviews for admissions?

    PubMed

    Hanson, Mark D; Kulasegaram, Kulamakan Mahan; Woods, Nicole N; Fechtig, Lindsey; Anderson, Geoff

    2012-10-01

    Traditional admissions personal interviews provide flexible faculty-student interactions but are plagued by low inter-interview reliability. Axelson and Kreiter (2009) retrospectively showed that multiple independent sampling (MIS) may improve reliability of personal interviews; thus, the authors incorporated MIS into the admissions process for medical students applying to the University of Toronto's Leadership Education and Development Program (LEAD). They examined the reliability and resource demands of this modified personal interview (MPI) format. In 2010-2011, LEAD candidates submitted written applications, which were used to screen for participation in the MPI process. Selected candidates completed four brief (10-12 minutes) independent MPIs each with a different interviewer. The authors blueprinted MPI questions to (i.e., aligned them with) leadership attributes, and interviewers assessed candidates' eligibility on a five-point Likert-type scale. The authors analyzed inter-interview reliability using the generalizability theory. Sixteen candidates submitted applications; 10 proceeded to the MPI stage. Reliability of the written application components was 0.75. The MPI process had overall inter-interview reliability of 0.79. Correlation between the written application and MPI scores was 0.49. A decision study showed acceptable reliability of 0.74 with only three MPIs scored using one global rating. Furthermore, a traditional admissions interview format would take 66% more time than the MPI format. The MPI format, used during the LEAD admissions process, achieved high reliability with minimal faculty resources. The MPI format's reliability and effective resource use were possible through MIS and employment of expert interviewers. MPIs may be useful for other admissions tasks.

  16. Reducing Bolt Preload Variation with Angle-of-Twist Bolt Loading

    NASA Technical Reports Server (NTRS)

    Thompson, Bryce; Nayate, Pramod; Smith, Doug; McCool, Alex (Technical Monitor)

    2001-01-01

    Critical high-pressure sealing joints on the Space Shuttle reusable solid rocket motor require precise control of bolt preload to ensure proper joint function. As the reusable solid rocket motor experiences rapid internal pressurization, correct bolt preloads maintain the sealing capability and structural integrity of the hardware. The angle-of-twist process provides the right combination of preload accuracy, reliability, process control, and assembly-friendly design. It improves significantly over previous methods. The sophisticated angle-of-twist process controls have yielded answers to all discrepancies encountered while the simplicity of the root process has assured joint preload reliability.

  17. Performance of intraclass correlation coefficient (ICC) as a reliability index under various distributions in scale reliability studies.

    PubMed

    Mehta, Shraddha; Bastero-Caballero, Rowena F; Sun, Yijun; Zhu, Ray; Murphy, Diane K; Hardas, Bhushan; Koch, Gary

    2018-04-29

    Many published scale validation studies determine inter-rater reliability using the intra-class correlation coefficient (ICC). However, the use of this statistic must consider its advantages, limitations, and applicability. This paper evaluates how interaction of subject distribution, sample size, and levels of rater disagreement affects ICC and provides an approach for obtaining relevant ICC estimates under suboptimal conditions. Simulation results suggest that for a fixed number of subjects, ICC from the convex distribution is smaller than ICC for the uniform distribution, which in turn is smaller than ICC for the concave distribution. The variance component estimates also show that the dissimilarity of ICC among distributions is attributed to the study design (ie, distribution of subjects) component of subject variability and not the scale quality component of rater error variability. The dependency of ICC on the distribution of subjects makes it difficult to compare results across reliability studies. Hence, it is proposed that reliability studies should be designed using a uniform distribution of subjects because of the standardization it provides for representing objective disagreement. In the absence of uniform distribution, a sampling method is proposed to reduce the non-uniformity. In addition, as expected, high levels of disagreement result in low ICC, and when the type of distribution is fixed, any increase in the number of subjects beyond a moderately large specification such as n = 80 does not have a major impact on ICC. Copyright © 2018 John Wiley & Sons, Ltd.

  18. Are We Hoping For A Bounce A Study On Resilience And Human Relations In A High Reliability Organization

    DTIC Science & Technology

    2016-03-01

    A BOUNCE? A STUDY ON RESILIENCE AND HUMAN RELATIONS IN A HIGH RELIABILITY ORGANIZATION by Robert D. Johns March 2016 Thesis Advisor...RELATIONS IN A HIGH RELIABILITY ORGANIZATION 5. FUNDING NUMBERS 6. AUTHOR(S) Robert D. Johns 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES...200 words) This study analyzes the various resilience factors associated with a military high reliability organization (HRO). The data measuring

  19. Test Assembly Implications for Providing Reliable and Valid Subscores

    ERIC Educational Resources Information Center

    Lee, Minji K.; Sweeney, Kevin; Melican, Gerald J.

    2017-01-01

    This study investigates the relationships among factor correlations, inter-item correlations, and the reliability estimates of subscores, providing a guideline with respect to psychometric properties of useful subscores. In addition, it compares subscore estimation methods with respect to reliability and distinctness. The subscore estimation…

  20. A Methodological Approach to Quantifying Plyometric Intensity.

    PubMed

    Jarvis, Mark M; Graham-Smith, Phil; Comfort, Paul

    2016-09-01

    Jarvis, MM, Graham-Smith, P, and Comfort, P. A Methodological approach to quantifying plyometric intensity. J Strength Cond Res 30(9): 2522-2532, 2016-In contrast to other methods of training, the quantification of plyometric exercise intensity is poorly defined. The purpose of this study was to evaluate the suitability of a range of neuromuscular and mechanical variables to describe the intensity of plyometric exercises. Seven male recreationally active subjects performed a series of 7 plyometric exercises. Neuromuscular activity was measured using surface electromyography (SEMG) at vastus lateralis (VL) and biceps femoris (BF). Surface electromyography data were divided into concentric (CON) and eccentric (ECC) phases of movement. Mechanical output was measured by ground reaction forces and processed to provide peak impact ground reaction force (PF), peak eccentric power (PEP), and impulse (IMP). Statistical analysis was conducted to assess the reliability intraclass correlation coefficient and sensitivity smallest detectable difference of all variables. Mean values of SEMG demonstrate high reliability (r ≥ 0.82), excluding ECC VL during a 40-cm drop jump (r = 0.74). PF, PEP, and IMP demonstrated high reliability (r ≥ 0.85). Statistical power for force variables was excellent (power = 1.0), and good for SEMG (power ≥0.86) excluding CON BF (power = 0.57). There was no significant difference (p > 0.05) in CON SEMG between exercises. Eccentric phase SEMG only distinguished between exercises involving a landing and those that did not (percentage of maximal voluntary isometric contraction [%MVIC] = no landing -65 ± 5, landing -140 ± 8). Peak eccentric power, PF, and IMP all distinguished between exercises. In conclusion, CON neuromuscular activity does not appear to vary when intent is maximal, whereas ECC activity is dependent on the presence of a landing. Force characteristics provide a reliable and sensitive measure enabling precise description of intensity in plyometric exercises. The present findings provide coaches and scientists with an insightful and precise method of measuring intensity in plyometrics, which will allow for greater control of programming variables.

  1. CSTI high capacity power. [Civil Space Technology Initiative

    NASA Technical Reports Server (NTRS)

    Winter, Jerry M.

    1989-01-01

    In FY-88, the Advanced Technology Program was incorporated into NASA's Civil Space Technology Initiative (CSTI). The CSTI Program was established to provide the foundation for technology development in automation and robotics, information, propulsion, and power. The CSTI High Capacity Power Program builds on the technology efforts of the SP-100 program, incorporates the previous NASA SP-100 Advanced Technology project, and provides a bridge to NASA Project Pathfinder. The elements of CSTI High Capacity Power development include Converrsion Systems, Thermal Management, Power Management, System Diagnostics, and Environmental Interactions. Technology advancement in all areas, including materials, is required to assure the high reliability and 7 to 10 year lifetime demanded for future space nuclear power systems.

  2. Common Badging and Access Control System (CBACS)

    NASA Technical Reports Server (NTRS)

    Baldridge, Tim

    2005-01-01

    The goals of the project are: Achieve high business value through a common badging and access control system that integrates with smart cards. Provide physical (versus logical) deployment of smart cards initially. Provides a common consistent and reliable environment into which to release the smart card. Gives opportunity to develop agency-wide consistent processes, practices and policies. Enables enterprise data capture and management. Promotes data validation prior to SC issuance.

  3. A highly reliable, high performance open avionics architecture for real time Nap-of-the-Earth operations

    NASA Technical Reports Server (NTRS)

    Harper, Richard E.; Elks, Carl

    1995-01-01

    An Army Fault Tolerant Architecture (AFTA) has been developed to meet real-time fault tolerant processing requirements of future Army applications. AFTA is the enabling technology that will allow the Army to configure existing processors and other hardware to provide high throughput and ultrahigh reliability necessary for TF/TA/NOE flight control and other advanced Army applications. A comprehensive conceptual study of AFTA has been completed that addresses a wide range of issues including requirements, architecture, hardware, software, testability, producibility, analytical models, validation and verification, common mode faults, VHDL, and a fault tolerant data bus. A Brassboard AFTA for demonstration and validation has been fabricated, and two operating systems and a flight-critical Army application have been ported to it. Detailed performance measurements have been made of fault tolerance and operating system overheads while AFTA was executing the flight application in the presence of faults.

  4. Commercialized VCSEL components fabricated at TrueLight Corporation

    NASA Astrophysics Data System (ADS)

    Pan, Jin-Shan; Lin, Yung-Sen; Li, Chao-Fang A.; Chang, C. H.; Wu, Jack; Lee, Bor-Lin; Chuang, Y. H.; Tu, S. L.; Wu, Calvin; Huang, Kai-Feng

    2001-05-01

    TrueLight Corporation was found in 1997 and it is the pioneer of VCSEL components supplier in Taiwan. We specialize in the production and distribution of VCSEL (Vertical Cavity Surface Emitting Laser) and other high-speed PIN-detector devices and components. Our core technology is developed to meet blooming demand of fiber optic transmission. Our intention is to diverse the device application into data communication, telecommunication and industrial markets. One mission is to provide the high performance, highly reliable and low-cost VCSEL components for data communication and sensing applications. For the past three years, TrueLight Corporation has entered successfully into the Gigabit Ethernet and the Fiber Channel data communication area. In this paper, we will focus on the fabrication of VCSEL components. We will present you the evolution of implanted and oxide-confined VCSEL process, device characterization, also performance in Gigabit data communication and the most important reliability issue

  5. The Case for Modular Redundancy in Large-Scale High Performance Computing Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Engelmann, Christian; Ong, Hong Hoe; Scott, Stephen L

    2009-01-01

    Recent investigations into resilience of large-scale high-performance computing (HPC) systems showed a continuous trend of decreasing reliability and availability. Newly installed systems have a lower mean-time to failure (MTTF) and a higher mean-time to recover (MTTR) than their predecessors. Modular redundancy is being used in many mission critical systems today to provide for resilience, such as for aerospace and command \\& control systems. The primary argument against modular redundancy for resilience in HPC has always been that the capability of a HPC system, and respective return on investment, would be significantly reduced. We argue that modular redundancy can significantly increasemore » compute node availability as it removes the impact of scale from single compute node MTTR. We further argue that single compute nodes can be much less reliable, and therefore less expensive, and still be highly available, if their MTTR/MTTF ratio is maintained.« less

  6. Developing of an automation for therapy dosimetry systems by using labview software

    NASA Astrophysics Data System (ADS)

    Aydin, Selim; Kam, Erol

    2018-06-01

    Traceability, accuracy and consistency of radiation measurements are essential in radiation dosimetry, particularly in radiotherapy, where the outcome of treatments is highly dependent on the radiation dose delivered to patients. Therefore it is very important to provide reliable, accurate and fast calibration services for therapy dosimeters since the radiation dose delivered to a radiotherapy patient is directly related to accuracy and reliability of these devices. In this study, we report the performance of in-house developed computer controlled data acquisition and monitoring software for the commercially available radiation therapy electrometers. LabVIEW® software suite is used to provide reliable, fast and accurate calibration services. The software also collects environmental data such as temperature, pressure and humidity in order to use to use these them in correction factor calculations. By using this software tool, a better control over the calibration process is achieved and the need for human intervention is reduced. This is the first software that can control frequently used dosimeter systems, in radiation thereapy field at hospitals, such as Unidos Webline, Unidos E, Dose-1 and PC Electrometers.

  7. Using Reliability to Meet Z540.3's 2 percent Rule

    NASA Technical Reports Server (NTRS)

    Mimbs, Scott M.

    2011-01-01

    NASA's Kennedy Space Center (KSC) undertook implementation of ANSI/NCSL Z540.3-2006 in October 2008. Early in the implementation, KSC identified that the largest cost driver of Z540.3 implementation is measurement uncertainty analyses for legacy calibration processes. NASA, like other organizations, has a significant inventory of measuring and test equipment (MTE) that have documented calibration procedures without documented measurement uncertainties. This paper provides background information to support the rationale for using high in-tolerance reliability as evidence of compliance to the 2% probability of false acceptance (PFA) quality metric of ANSI/NCSL Z540.3-2006 allowing use of qualifying legacy processes. NASA is adopting this as policy and is recommending NCSL International consider this as a method of compliance to Z540.3. Topics covered include compliance issues, using end-of-period reliability (EOPR) to estimate test point uncertainty, reliability data influences within the PFA model, the validity of EOPR data, and an appendix covering "observed" versus "true" EOPR.

  8. Reliability and validity of a Swedish language version of the Resilience Scale.

    PubMed

    Nygren, Björn; Randström, Kerstin Björkman; Lejonklou, Anna K; Lundman, Beril

    2004-01-01

    The purpose of this study was to test the reliability and validity of the Swedish language version of the Resilience Scale (RS). Participants were 142 adults between 19-85 years of age. Internal consistency reliability, stability over time, and construct validity were evaluated using Cronbach's alpha, principal components analysis with varimax rotation and correlations with scores on the Sense of Coherence Scale (SOC) and the Rosenberg Self-Esteem Scale (RSE). The mean score on the RS was 142 (SD = 15). The possible scores on the RS range from 25 to 175, and scores higher than 146 are considered high. The test-retest correlation was .78. Correlations with the SOC and the RSE were .41 (p < 0.01) and .37 (p < 0.01), respectively. Personal Assurance and Acceptance of Self and Life emerged as components from the principal components analysis. These findings provide evidence for the reliability and validity of the Swedish language version of the RS.

  9. Enhanced Component Performance Study: Air-Operated Valves 1998-2014

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schroeder, John Alton

    2015-11-01

    This report presents a performance evaluation of air-operated valves (AOVs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2014 for the component reliability as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The AOV failure modes considered are failure-to-open/close, failure to operate or control, and spurious operation. The component reliability estimates and the reliability data are trended for the most recent 10-year period, while yearly estimates for reliability are provided for the entire active period. One statistically significantmore » trend was observed in the AOV data: The frequency of demands per reactor year for valves recording the fail-to-open or fail-to-close failure modes, for high-demand valves (those with greater than twenty demands per year), was found to be decreasing. The decrease was about three percent over the ten year period trended.« less

  10. Detection of single bacteria - causative agents of meningitis using raman microscopy

    NASA Astrophysics Data System (ADS)

    Baikova, T. V.; Minaeva, S. A.; Sundukov, A. V.; Svistunova, T. S.; Bagratashvili, V. N.; Alushin, M. V.; Gonchukov, S. A.

    2015-03-01

    Early diagnostics of meningitis is a very topical problem as it is a fulminant disease with a high level of mortality. The progress of this disease is, as a rule, accompanied by the appearance of bacteria in the cerebrospinal fluid (CSF) composition. The examination of the CSF is well known to be the only reliable approach to the identification of meningitis. However, the traditional biochemical analyses are time consuming and not always reliable, simple, and inexpensive, whereas the optical methods are poorly developed. This work is devoted to the study of Raman spectra of several bacterial cultures which are mainly present during meningitis. Raman microscopy is a prompt and noninvasive technique capable of providing reliable information about molecular-level alterations of biological objects at their minimal quantity and size. It was shown that there are characteristic lines in Raman spectra which can be the reliable markers for determination of bacterial form of meningitis at a level of a single bacterium.

  11. Design and Performance Evaluation of a 200 deg C Interleaved Boost Converter (Preprint)

    DTIC Science & Technology

    2012-09-01

    applications in which longer life operation is desired, SiC die are brazed in metal TO-257 hermetic packages, which do provide superior high temperature ...reliability. Optimization of a high temperature X-perm core based coupled inductor architecture, in terms of ac flux balancing and dc flux cancellation...by ~60% due to the rapid decline in X7R capacitance at the high temperature extreme. The results obtained during this study suggest that the

  12. Psychometric properties and normative data for the Brief Symptom Inventory-18 (BSI-18) in high school and collegiate athletes

    PubMed Central

    McCrea, Michael A.; Nelson, Lindsay D.

    2016-01-01

    Objective Assessment of emotional functioning is important in sport-related concussion (SRC) management, although few standardized measures have been validated in this population, and appropriate normative data are lacking. We investigated the psychometric properties of the Brief Symptom Inventory-18 (BSI-18) in high school and collegiate athletes at risk of SRC and compiled normative data. Method Athletes (n = 2,031) completed the BSI-18 and other measures of concussion symptoms, cognition, and psychological functioning. A subset of healthy individuals was re-evaluated at approximately 7, 30, 45, and 165 days. Psychometric analyses of test–retest reliability, internal consistency reliability, and concurrent validity were performed. Given significant differences between sexes and education levels (high school or college student) on the BSI-18 Global Severity Index and all subscales, normative conversion tables were produced after stratifying by these variables. Results The BSI-18 showed good internal consistency, fair to poor test–retest reliability, and good convergent validity with other measures of emotional functioning. Conclusions These data indicate that the BSI-18 may be a valuable measure of emotional state in concussed athletes and may provide unique information beyond post-concussive symptoms for research on the role of psychological factors in SRC recovery. The limited divergent validity of the BSI-18 depression and anxiety scales implies that they tap into general distress more so than specific mood or anxiety symptoms; therefore, BSI-18 scores should be not relied upon for differential diagnosis of mood and anxiety disorders. Normative data provided can be readily applied to clinical cases with high school and collegiate athletes. PMID:26924037

  13. Digging Deeper: Crisis Management in the Coal Industry

    ERIC Educational Resources Information Center

    Miller, Barbara M.; Horsley, J. Suzanne

    2009-01-01

    This study explores crisis management/communication practices within the coal industry through the lens of high reliability organization (HRO) concepts and sensemaking theory. In-depth interviews with industry executives and an analysis of an emergency procedures manual were used to provide an exploratory examination of the status of crisis…

  14. International English Language Testing: A Critical Response

    ERIC Educational Resources Information Center

    Hall, Graham

    2010-01-01

    Uysal's article provides a research agenda for IELTS and lists numerous issues concerning the test's reliability and validity. She asks useful questions, but her analysis ignores the uncertainties inherent in all language test development and the wider social and political context of international high-stakes language testing. In this response, I…

  15. 49 CFR 195.452 - Pipeline integrity management in high consequence areas.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... engineering evaluation and provides an equivalent level of public safety and environmental protection. (c... situations—(i) Engineering basis. An operator may be able to justify an engineering basis for a longer assessment interval on a segment of line pipe. The justification must be supported by a reliable engineering...

  16. A Rich Metadata Filesystem for Scientific Data

    ERIC Educational Resources Information Center

    Bui, Hoang

    2012-01-01

    As scientific research becomes more data intensive, there is an increasing need for scalable, reliable, and high performance storage systems. Such data repositories must provide both data archival services and rich metadata, and cleanly integrate with large scale computing resources. ROARS is a hybrid approach to distributed storage that provides…

  17. 76 FR 75492 - Atlantic Highly Migratory Species; Vessel Monitoring Systems

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-02

    ... and fishing gears possessed to be made by phone. Some small fishing vessels remain within cell phone... terminals represent a more reliable means of communication than cellular phones because they use satellites rather than cell towers as the principle means of transmitting data. Furthermore, vessels need to provide...

  18. 78 FR 69755 - International Product and Price Changes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-21

    ... provides reliable, high-speed service to over 185 countries with a money-back, date- certain delivery... Price Group Price groups 1-14 will have shaped-based pricing and will be require separate containers (i... decrease the minimum weight for a direct country container from 3 pounds to 2 pounds. Destination Countries...

  19. The Mindful Attention Awareness Scale (MAAS) in an Argentine Population

    ERIC Educational Resources Information Center

    Montes, Silvana Andrea; Ledesma, Rubén Daniel; García, Natalia Mariana; Poó, Fernando Martín

    2014-01-01

    The purpose of this study was to provide evidence of validity for the Mindful Attention Awareness Scale scores in an Argentine sample (Spanish-language version). Results indicated satisfactory psychometric properties (a one-factor structure, good item discrimination, high reliability, and significant correlations with additional measures). This…

  20. PHOBOS Exploration using Two Small Solar Electric Propulsion (SEP) Spacecraft

    NASA Technical Reports Server (NTRS)

    Lang, J. J.; Baker, J. D.; McElrath, T. P.; Piacentine, J. S.; Snyder, J. S.

    2012-01-01

    Phobos Surveyor Mission concept provides an innovative low cost, highly reliable approach to exploring the inner solar system 1/16/2013 3 Dual manifest launch. Use only flight proven, well characterize commercial off-the-shelf components. Flexible mission architecture allows for a slew of unique measurements.

  1. Critical Electronic Data Loss Perceptions of United States Military Contractors

    ERIC Educational Resources Information Center

    Singletary, Tod J.

    2017-01-01

    The United States Military has become increasingly dependent upon technology to meet its mission objectives with a consequence being greater dependence on civilian defense contractors to provide specialized services in support of high-tech mission requirements. Modern military defense contractors have also become dependent upon reliable and secure…

  2. Space Shuttle Software Development and Certification

    NASA Technical Reports Server (NTRS)

    Orr, James K.; Henderson, Johnnie A

    2000-01-01

    Man-rated software, "software which is in control of systems and environments upon which human life is critically dependent," must be highly reliable. The Space Shuttle Primary Avionics Software System is an excellent example of such a software system. Lessons learn from more than 20 years of effort have identified basic elements that must be present to achieve this high degree of reliability. The elements include rigorous application of appropriate software development processes, use of trusted tools to support those processes, quantitative process management, and defect elimination and prevention. This presentation highlights methods used within the Space Shuttle project and raises questions that must be addressed to provide similar success in a cost effective manner on future long-term projects where key application development tools are COTS rather than internally developed custom application development tools

  3. Perceptions of high-achieving African American/Black tenth graders from a low socioeconomic community regarding health scientists and desired careers.

    PubMed

    Boekeloo, Bradley; Randolph, Suzanne; Timmons-Brown, Stephanie; Wang, Min Qi

    2014-08-01

    Measures are needed to assess youth perceptions about health science careers to facilitate research aimed at increasing youth pursuit of health science. Although the Indiana Instrument provides an established measure of perceptions regarding nursing and ideal careers, we were interested in learning how high-achieving 10th graders from relatively low socioeconomic areas who identify as black/African American (black) perceive health science and ideal careers. The Indiana Instrument was modified, administered to 90 youth of interest, and psychometrically analyzed. Reliable subscales were identified that may facilitate parsimonious, theoretical, and reliable study of youth decision-making regarding health science careers. Such research may help to develop and evaluate strategies for increasing the number of minority health scientists.

  4. Magnetic resonance imaging can accurately assess the long-term progression of knee structural changes in experimental dog osteoarthritis.

    PubMed

    Boileau, C; Martel-Pelletier, J; Abram, F; Raynauld, J-P; Troncy, E; D'Anjou, M-A; Moreau, M; Pelletier, J-P

    2008-07-01

    Osteoarthritis (OA) structural changes take place over decades in humans. MRI can provide precise and reliable information on the joint structure and changes over time. In this study, we investigated the reliability of quantitative MRI in assessing knee OA structural changes in the experimental anterior cruciate ligament (ACL) dog model of OA. OA was surgically induced by transection of the ACL of the right knee in five dogs. High resolution three dimensional MRI using a 1.5 T magnet was performed at baseline, 4, 8 and 26 weeks post surgery. Cartilage volume/thickness, cartilage defects, trochlear osteophyte formation and subchondral bone lesion (hypersignal) were assessed on MRI images. Animals were killed 26 weeks post surgery and macroscopic evaluation was performed. There was a progressive and significant increase over time in the loss of knee cartilage volume, the cartilage defect and subchondral bone hypersignal. The trochlear osteophyte size also progressed over time. The greatest cartilage loss at 26 weeks was found on the tibial plateaus and in the medial compartment. There was a highly significant correlation between total knee cartilage volume loss or defect and subchondral bone hypersignal, and also a good correlation between the macroscopic and the MRI findings. This study demonstrated that MRI is a useful technology to provide a non-invasive and reliable assessment of the joint structural changes during the development of OA in the ACL dog model. The combination of this OA model with MRI evaluation provides a promising tool for the evaluation of new disease-modifying osteoarthritis drugs (DMOADs).

  5. Finger tapping impairments are highly sensitive for evaluating upper motor neuron lesions.

    PubMed

    Shirani, Afsaneh; Newton, Braeden D; Okuda, Darin T

    2017-03-21

    Identifying highly sensitive and reliable neurological exam components are crucial in recognizing clinical deficiencies. This study aimed to investigate finger tapping performance differences between patients with CNS demyelinating lesions and healthy control subjects. Twenty-three patients with multiple sclerosis or clinically isolated syndrome with infratentorial and/or cervical cord lesions on MRI, and 12 healthy controls were videotaped while tapping the tip of the index finger against the tip and distal crease of the thumb using both the dominant and non-dominant hand. Videos were assessed independently by 10 evaluators (three MS neurologists, four neurology residents, three advanced practice providers). Sensitivity and inter-evaluator reliability of finger tapping interpretations were calculated. A total of 1400 evaluations (four videos per each of the 35 subjects evaluated by 10 independent providers) were obtained. Impairments in finger tapping against the distal thumb crease of the non-dominant hand, identified by neurologists, had the greatest sensitivity (84%, p < 0.001) for detecting impairment. Finger tapping against the thumb crease was more sensitive than the thumb tip across all categories of providers. The best inter-evaluator reliability was associated with neurologists' evaluations for the thumb crease of the non-dominant hand (kappa = 0.83, p < 0.001). Impaired finger tapping against the distal thumb crease of the non-dominant hand was a more sensitive technique for detecting impairments related to CNS demyelinating lesions. Our findings highlight the importance of precise examinations of the non-dominant side where impaired fine motor control secondary to an upper motor injury might be detectable earlier than the dominant side.

  6. Reliable motion detection of small targets in video with low signal-to-clutter ratios

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nichols, S.A.; Naylor, R.B.

    1995-07-01

    Studies show that vigilance decreases rapidly after several minutes when human operators are required to search live video for infrequent intrusion detections. Therefore, there is a need for systems which can automatically detect targets in live video and reserve the operator`s attention for assessment only. Thus far, automated systems have not simultaneously provided adequate detection sensitivity, false alarm suppression, and ease of setup when used in external, unconstrained environments. This unsatisfactory performance can be exacerbated by poor video imagery with low contrast, high noise, dynamic clutter, image misregistration, and/or the presence of small, slow, or erratically moving targets. This papermore » describes a highly adaptive video motion detection and tracking algorithm which has been developed as part of Sandia`s Advanced Exterior Sensor (AES) program. The AES is a wide-area detection and assessment system for use in unconstrained exterior security applications. The AES detection and tracking algorithm provides good performance under stressing data and environmental conditions. Features of the algorithm include: reliable detection with negligible false alarm rate of variable velocity targets having low signal-to-clutter ratios; reliable tracking of targets that exhibit motion that is non-inertial, i.e., varies in direction and velocity; automatic adaptation to both infrared and visible imagery with variable quality; and suppression of false alarms caused by sensor flaws and/or cutouts.« less

  7. Reliable Wireless Broadcast with Linear Network Coding for Multipoint-to-Multipoint Real-Time Communications

    NASA Astrophysics Data System (ADS)

    Kondo, Yoshihisa; Yomo, Hiroyuki; Yamaguchi, Shinji; Davis, Peter; Miura, Ryu; Obana, Sadao; Sampei, Seiichi

    This paper proposes multipoint-to-multipoint (MPtoMP) real-time broadcast transmission using network coding for ad-hoc networks like video game networks. We aim to achieve highly reliable MPtoMP broadcasting using IEEE 802.11 media access control (MAC) that does not include a retransmission mechanism. When each node detects packets from the other nodes in a sequence, the correctly detected packets are network-encoded, and the encoded packet is broadcasted in the next sequence as a piggy-back for its native packet. To prevent increase of overhead in each packet due to piggy-back packet transmission, network coding vector for each node is exchanged between all nodes in the negotiation phase. Each user keeps using the same coding vector generated in the negotiation phase, and only coding information that represents which user signal is included in the network coding process is transmitted along with the piggy-back packet. Our simulation results show that the proposed method can provide higher reliability than other schemes using multi point relay (MPR) or redundant transmissions such as forward error correction (FEC). We also implement the proposed method in a wireless testbed, and show that the proposed method achieves high reliability in a real-world environment with a practical degree of complexity when installed on current wireless devices.

  8. Real-Time GNSS-Based Attitude Determination in the Measurement Domain

    PubMed Central

    Zhao, Lin; Li, Na; Li, Liang; Zhang, Yi; Cheng, Chun

    2017-01-01

    A multi-antenna-based GNSS receiver is capable of providing high-precision and drift-free attitude solution. Carrier phase measurements need be utilized to achieve high-precision attitude. The traditional attitude determination methods in the measurement domain and the position domain resolve the attitude and the ambiguity sequentially. The redundant measurements from multiple baselines have not been fully utilized to enhance the reliability of attitude determination. A multi-baseline-based attitude determination method in the measurement domain is proposed to estimate the attitude parameters and the ambiguity simultaneously. Meanwhile, the redundancy of attitude resolution has also been increased so that the reliability of ambiguity resolution and attitude determination can be enhanced. Moreover, in order to further improve the reliability of attitude determination, we propose a partial ambiguity resolution method based on the proposed attitude determination model. The static and kinematic experiments were conducted to verify the performance of the proposed method. When compared with the traditional attitude determination methods, the static experimental results show that the proposed method can improve the accuracy by at least 0.03° and enhance the continuity by 18%, at most. The kinematic result has shown that the proposed method can obtain an optimal balance between accuracy and reliability performance. PMID:28165434

  9. Maximally reliable spatial filtering of steady state visual evoked potentials.

    PubMed

    Dmochowski, Jacek P; Greaves, Alex S; Norcia, Anthony M

    2015-04-01

    Due to their high signal-to-noise ratio (SNR) and robustness to artifacts, steady state visual evoked potentials (SSVEPs) are a popular technique for studying neural processing in the human visual system. SSVEPs are conventionally analyzed at individual electrodes or linear combinations of electrodes which maximize some variant of the SNR. Here we exploit the fundamental assumption of evoked responses--reproducibility across trials--to develop a technique that extracts a small number of high SNR, maximally reliable SSVEP components. This novel spatial filtering method operates on an array of Fourier coefficients and projects the data into a low-dimensional space in which the trial-to-trial spectral covariance is maximized. When applied to two sample data sets, the resulting technique recovers physiologically plausible components (i.e., the recovered topographies match the lead fields of the underlying sources) while drastically reducing the dimensionality of the data (i.e., more than 90% of the trial-to-trial reliability is captured in the first four components). Moreover, the proposed technique achieves a higher SNR than that of the single-best electrode or the Principal Components. We provide a freely-available MATLAB implementation of the proposed technique, herein termed "Reliable Components Analysis". Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Prediction of Geomagnetic Activity and Key Parameters in High-Latitude Ionosphere-Basic Elements

    NASA Technical Reports Server (NTRS)

    Lyatsky, W.; Khazanov, G. V.

    2007-01-01

    Prediction of geomagnetic activity and related events in the Earth's magnetosphere and ionosphere is an important task of the Space Weather program. Prediction reliability is dependent on the prediction method and elements included in the prediction scheme. Two main elements are a suitable geomagnetic activity index and coupling function -- the combination of solar wind parameters providing the best correlation between upstream solar wind data and geomagnetic activity. The appropriate choice of these two elements is imperative for any reliable prediction model. The purpose of this work was to elaborate on these two elements -- the appropriate geomagnetic activity index and the coupling function -- and investigate the opportunity to improve the reliability of the prediction of geomagnetic activity and other events in the Earth's magnetosphere. The new polar magnetic index of geomagnetic activity and the new version of the coupling function lead to a significant increase in the reliability of predicting the geomagnetic activity and some key parameters, such as cross-polar cap voltage and total Joule heating in high-latitude ionosphere, which play a very important role in the development of geomagnetic and other activity in the Earth s magnetosphere, and are widely used as key input parameters in modeling magnetospheric, ionospheric, and thermospheric processes.

  11. Development and validation of an instrument for evaluating inquiry-based tasks in science textbooks

    NASA Astrophysics Data System (ADS)

    Yang, Wenyuan; Liu, Enshan

    2016-12-01

    This article describes the development and validation of an instrument that can be used for content analysis of inquiry-based tasks. According to the theories of educational evaluation and qualities of inquiry, four essential functions that inquiry-based tasks should serve are defined: (1) assisting in the construction of understandings about scientific concepts, (2) providing students opportunities to use inquiry process skills, (3) being conducive to establishing understandings about scientific inquiry, and (4) giving students opportunities to develop higher order thinking skills. An instrument - the Inquiry-Based Tasks Analysis Inventory (ITAI) - was developed to judge whether inquiry-based tasks perform these functions well. To test the reliability and validity of the ITAI, 4 faculty members were invited to use the ITAI to collect data from 53 inquiry-based tasks in the 3 most widely adopted senior secondary biology textbooks in Mainland China. The results indicate that (1) the inter-rater reliability reached 87.7%, (2) the grading criteria have high discriminant validity, (3) the items possess high convergent validity, and (4) the Cronbach's alpha reliability coefficient reached 0.792. The study concludes that the ITAI is valid and reliable. Because of its solid foundations in theoretical and empirical argumentation, the ITAI is trustworthy.

  12. Validation of the secretion severity rating scale.

    PubMed

    Pluschinski, Petra; Zaretsky, Eugen; Stöver, Timo; Murray, Joseph; Sader, Robert; Hey, Christiane

    2016-10-01

    Accumulation of secretions within the hypopharynx, aditus laryngis, and trachea is one characteristic of severe dysphagia and is of high clinical and therapeutic relevance. For the graduation of the secretion severity level, a secretion scale was provided by Murray et al. in 1996. The purpose of the study presented here is the validation of this scale by analyzing the intra-rater and inter-rater reliability as well as concurrent validity. For examination of reliability and validity, a reference standard was defined by two expert clinicians who reviewed 40 video recordings of fiberendoscopic swallowing evaluations, with 10 videos for each severity grade. These videos were rated and rerated independently and blinded by 4 ENT-residents with an interval of 4 weeks. Both the intra-rater (Kendall's τ > 0.847***) and inter-rater reliability (Kendall's W > 0.951***) were highly significant and can be considered good or very good. Correlation of the median of all ratings with the reference standard was close to the highest possible value 1 (τ = 0.984***). The scale was proved to be a reliable and valid instrument for graduation of one of the principal symptoms of oropharyngeal dysphagia and is recommended as an evidence-based instrument for standardized fiberoptic endoscopic evaluation of swallowing.

  13. Extended version of the "Sniffin' Sticks" identification test: test-retest reliability and validity.

    PubMed

    Sorokowska, A; Albrecht, E; Haehner, A; Hummel, T

    2015-03-30

    The extended, 32-item version of the Sniffin' Sticks identification test was developed in order to create a precise tool enabling repeated, longitudinal testing of individual olfactory subfunctions. Odors of the previous test version had to be changed for technical reasons, and the odor identification test needed re-investigation in terms of reliability, validity, and normative values. In our study we investigated olfactory abilities of a group of 100 patients with olfactory dysfunction and 100 controls. We reconfirmed the high test-retest reliability of the extended version of the Sniffin' Sticks identification test and high correlations between the new and the original part of this tool. In addition, we confirmed the validity of the test as it discriminated clearly between controls and patients with olfactory loss. The additional set of 16 odor identification sticks can be either included in the current olfactory test, thus creating a more detailed diagnosis tool, or it can be used separately, enabling to follow olfactory function over time. Additionally, the normative values presented in our paper might provide useful guidelines for interpretation of the extended identification test results. The revised version of the Sniffin' Sticks 32-item odor identification test is a reliable and valid tool for the assessment of olfactory function. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Interrater Reliability of the Power Mobility Road Test in the Virtual Reality-Based Simulator-2.

    PubMed

    Kamaraj, Deepan C; Dicianno, Brad E; Mahajan, Harshal P; Buhari, Alhaji M; Cooper, Rory A

    2016-07-01

    To assess interrater reliability of the Power Mobility Road Test (PMRT) when administered through the Virtual Reality-based SIMulator-version 2 (VRSIM-2). Within-subjects repeated-measures design. Participants interacted with VRSIM-2 through 2 display options (desktop monitor vs immersive virtual reality screens) using 2 control interfaces (roller system vs conventional movement-sensing joystick), providing 4 different driving scenarios (driving conditions 1-4). Participants performed 3 virtual driving sessions for each of the 2 display screens and 1 session through a real-world driving course (driving condition 5). The virtual PMRT was conducted in a simulated indoor office space, and an equivalent course was charted in an open space for the real-world assessment. After every change in driving condition, participants completed a self-reported workload assessment questionnaire, the Task Load Index, developed by the National Aeronautics and Space Administration. A convenience sample of electric-powered wheelchair (EPW) athletes (N=21) recruited at the 31st National Veterans Wheelchair Games. Not applicable. Total composite PMRT score. The PMRT had high interrater reliability (intraclass correlation coefficient [ICC]>.75) between the 2 raters in all 5 driving conditions. Post hoc analyses revealed that the reliability analyses had >80% power to detect high ICCs in driving conditions 1 and 4. The PMRT has high interrater reliability in conditions 1 and 4 and could be used to assess EPW driving performance virtually in VRSIM-2. However, further psychometric assessment is necessary to assess the feasibility of administering the PMRT using the different interfaces of VRSIM-2. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  15. The children's menu assessment: development, evaluation, and relevance of a tool for evaluating children's menus.

    PubMed

    Krukowski, Rebecca A; Eddings, Kenya; West, Delia Smith

    2011-06-01

    Restaurant foods represent a substantial portion of children's dietary intake, and consumption of foods away from home has been shown to contribute to excess adiposity. This descriptive study aimed to pilot-test and establish the reliability of a standardized and comprehensive assessment tool, the Children's Menu Assessment, for evaluating the restaurant food environment for children. The tool is an expansion of the Nutrition Environment Measures Survey-Restaurant. In 2009-2010, a randomly selected sample of 130 local and chain restaurants were chosen from within 20 miles of Little Rock, AR, to examine the availability of children's menus and to conduct initial calibration of the Children's Menu Assessment tool (final sample: n=46). Independent raters completed the Children's Menu Assessment in order to determine inter-rater reliability. Test-retest reliability was also examined. Inter-rater reliability was high: percent agreement was 97% and Spearman correlation was 0.90. Test-retest was also high: percent agreement was 91% and Spearman correlation was 0.96. Mean Children's Menu Assessment completion time was 14 minutes, 56 seconds ± 10 minutes, 21 seconds. Analysis of Children's Menu Assessment findings revealed that few healthier options were available on children's menus, and most menus did not provide parents with information for making healthy choices, including nutrition information or identification of healthier options. The Children's Menu Assessment tool allows for comprehensive, rapid measurement of the restaurant food environment for children with high inter-rater reliability. This tool has the potential to contribute to public health efforts to develop and evaluate targeted environmental interventions and/or policy changes regarding restaurant foods. Copyright © 2011 American Dietetic Association. Published by Elsevier Inc. All rights reserved.

  16. Reliable and fast volumetry of the lumbar spinal cord using cord image analyser (Cordial).

    PubMed

    Tsagkas, Charidimos; Altermatt, Anna; Bonati, Ulrike; Pezold, Simon; Reinhard, Julia; Amann, Michael; Cattin, Philippe; Wuerfel, Jens; Fischer, Dirk; Parmar, Katrin; Fischmann, Arne

    2018-04-30

    To validate the precision and accuracy of the semi-automated cord image analyser (Cordial) for lumbar spinal cord (SC) volumetry in 3D T1w MRI data of healthy controls (HC). 40 3D T1w images of 10 HC (w/m: 6/4; age range: 18-41 years) were acquired at one 3T-scanner in two MRI sessions (time interval 14.9±6.1 days). Each subject was scanned twice per session, allowing determination of test-retest reliability both in back-to-back (intra-session) and scan-rescan images (inter-session). Cordial was applied for lumbar cord segmentation twice per image by two raters, allowing for assessment of intra- and inter-rater reliability, and compared to a manual gold standard. While manually segmented volumes were larger (mean: 2028±245 mm 3 vs. Cordial: 1636±300 mm 3 , p<0.001), accuracy assessments between manually and semi-automatically segmented images showed a mean Dice-coefficient of 0.88±0.05. Calculation of within-subject coefficients of variation (COV) demonstrated high intra-session (1.22-1.86%), inter-session (1.26-1.84%), as well as intra-rater (1.73-1.83%) reproducibility. No significant difference was shown between intra- and inter-session reproducibility or between intra-rater reliabilities. Although inter-rater reproducibility (COV: 2.87%) was slightly lower compared to all other reproducibility measures, between rater consistency was very strong (intraclass correlation coefficient: 0.974). While under-estimating the lumbar SCV, Cordial still provides excellent inter- and intra-session reproducibility showing high potential for application in longitudinal trials. • Lumbar spinal cord segmentation using the semi-automated cord image analyser (Cordial) is feasible. • Lumbar spinal cord is 40-mm cord segment 60 mm above conus medullaris. • Cordial provides excellent inter- and intra-session reproducibility in lumbar spinal cord region. • Cordial shows high potential for application in longitudinal trials.

  17. Development and validation of The Personal Diabetes Questionnaire (PDQ): a measure of diabetes self-care behaviors, perceptions and barriers.

    PubMed

    Stetson, Barbara; Schlundt, David; Rothschild, Chelsea; Floyd, Jennifer E; Rogers, Whitney; Mokshagundam, Sri Prakash

    2011-03-01

    To develop and evaluate the validity and reliability of The Personal Diabetes Questionnaire (PDQ), a brief, yet comprehensive measure of diabetes self-care behaviors, perceptions and barriers. To examine individual items to provide descriptive and normative information and provide data on scale reliability and associations between PDQ scales and concurrently assessed HBA(1c) and BMI. Items were written to address nutritional management, medication utilization, blood glucose monitoring, and physical activity. The initial instrument was reviewed by multidisciplinary diabetes care providers and items subsequently revised until the measure provided complete coverage of the diabetes care domains using as few items as possible. The scoring scheme was generated rationally. Subjects were 790 adults (205 with type 1 and 585 with type 2 diabetes) who completed the PDQ while waiting for clinic appointments. Item completion rates were high, with few items skipped by participants. Subscales demonstrated good internal consistency (Cronbach α=.650-.834) and demonstrated significant associations with BMI (p ≤.001) and HbA(1c) (p ≤.001). The PDQ is a useful measure of diabetes self-care behaviors and related perceptions and barriers that is reliable and valid and feasible to administer in a clinic setting. This measure may be used to obtain data for assessing diabetes self-management and barriers and to guide patient care. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  18. Confidence in outcome estimates from systematic reviews used in informed consent.

    PubMed

    Fritz, Robert; Bauer, Janet G; Spackman, Sue S; Bains, Amanjyot K; Jetton-Rangel, Jeanette

    2016-12-01

    Evidence-based dentistry now guides informed consent in which clinicians are obliged to provide patients with the most current, best evidence, or best estimates of outcomes, of regimens, therapies, treatments, procedures, materials, and equipment or devices when developing personal oral health care, treatment plans. Yet, clinicians require that the estimates provided from systematic reviews be verified to their validity, reliability, and contextualized as to performance competency so that clinicians may have confidence in explaining outcomes to patients in clinical practice. The purpose of this paper was to describe types of informed estimates from which clinicians may have confidence in their capacity to assist patients in competent decision-making, one of the most important concepts of informed consent. Using systematic review methodology, researchers provide clinicians with valid best estimates of outcomes regarding a subject of interest from best evidence. Best evidence is verified through critical appraisals using acceptable sampling methodology either by scoring instruments (Timmer analysis) or checklist (grade), a Cochrane Collaboration standard that allows transparency in open reviews. These valid best estimates are then tested for reliability using large databases. Finally, valid and reliable best estimates are assessed for meaning using quantification of margins and uncertainties. Through manufacturer and researcher specifications, quantification of margins and uncertainties develops a performance competency continuum by which valid, reliable best estimates may be contextualized for their performance competency: at a lowest margin performance competency (structural failure), high margin performance competency (estimated true value of success), or clinically determined critical values (clinical failure). Informed consent may be achieved when clinicians are confident of their ability to provide useful and accurate best estimates of outcomes regarding regimens, therapies, treatments, and equipment or devices to patients in their clinical practices and when developing personal, oral health care, treatment plans. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Staff preparedness for providing palliative and end-of-life care in long-term care homes: Instrument development and validation.

    PubMed

    Chan, Helen Yl; Chun, Gloria Km; Man, C W; Leung, Edward Mf

    2018-05-01

    Although much attention has been on integrating the palliative care approach into services of long-term care homes for older people living with frailty and progressive diseases, little is known about the staff preparedness for these new initiatives. The present study aimed to develop and test the psychometric properties of an instrument for measuring care home staff preparedness in providing palliative and end-of-life care. A 16-item instrument, covering perceived knowledge, skill and psychological readiness, was developed. A total of 247 staff members of different ranks from four care homes participated in the study. Exploratory factor analysis using the principal component analysis extraction method with varimax rotation was carried out for initial validation. Known group comparison was carried out to examine its discriminant validity. Reliability of the instrument was assessed based on test-retest reliability of a subsample of 20 participants and the Cronbach's alpha of the items. Exploratory factor analysis showed that the instrument yielded a three-factor solution, which cumulatively accounted for 68.5% of the total variance. Three subscales, namely, willingness, capability and resilience, showed high internal consistency and test-retest reliability. It also showed good discriminant validity between staff members of professional and non-professional groups. This is a brief, valid and reliable scale for measuring care home staff preparedness for providing palliative and end-of-life care. It can be used to identify their concerns and training needs in providing palliative and end-of-life care, and as an outcome measure to evaluate the effects of interventional studies for capacity building in this regard. Geriatr Gerontol Int 2018; 18: 745-749. © 2018 Japan Geriatrics Society.

  20. The Transition Readiness Assessment Questionnaire (TRAQ): its factor structure, reliability, and validity.

    PubMed

    Wood, David L; Sawicki, Gregory S; Miller, M David; Smotherman, Carmen; Lukens-Bull, Katryne; Livingood, William C; Ferris, Maria; Kraemer, Dale F

    2014-01-01

    National consensus statements recommend that providers regularly assess the transition readiness skills of adolescent and young adults (AYA). In 2010 we developed a 29-item version of Transition Readiness Assessment Questionnaire (TRAQ). We reevaluated item performance and factor structure, and reassessed the TRAQ's reliability and validity. We surveyed youth from 3 academic clinics in Jacksonville, Florida; Chapel Hill, North Carolina; and Boston, Massachusetts. Participants were AYA with special health care needs aged 14 to 21 years. From a convenience sample of 306 patients, we conducted item reduction strategies and exploratory factor analysis (EFA). On a second convenience sample of 221 patients, we conducted confirmatory factor analysis (CFA). Internal reliability was assessed by Cronbach's alpha and criterion validity. Analyses were conducted by the Wilcoxon rank sum test and mixed linear models. The item reduction and EFA resulted in a 20-item scale with 5 identified subscales. The CFA conducted on a second sample provided a good fit to the data. The overall scale has high reliability overall (Cronbach's alpha = .94) and good reliability for 4 of the 5 subscales (Cronbach's alpha ranging from .90 to .77 in the pooled sample). Each of the 5 subscale scores were significantly higher for adolescents aged 18 years and older versus those younger than 18 (P < .0001) in both univariate and multivariate analyses. The 20-item, 5-factor structure for the TRAQ is supported by EFA and CFA on independent samples and has good internal reliability and criterion validity. Additional work is needed to expand or revise the TRAQ subscales and test their predictive validity. Copyright © 2014 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  1. A quick aphasia battery for efficient, reliable, and multidimensional assessment of language function.

    PubMed

    Wilson, Stephen M; Eriksson, Dana K; Schneck, Sarah M; Lucanie, Jillian M

    2018-01-01

    This paper describes a quick aphasia battery (QAB) that aims to provide a reliable and multidimensional assessment of language function in about a quarter of an hour, bridging the gap between comprehensive batteries that are time-consuming to administer, and rapid screening instruments that provide limited detail regarding individual profiles of deficits. The QAB is made up of eight subtests, each comprising sets of items that probe different language domains, vary in difficulty, and are scored with a graded system to maximize the informativeness of each item. From the eight subtests, eight summary measures are derived, which constitute a multidimensional profile of language function, quantifying strengths and weaknesses across core language domains. The QAB was administered to 28 individuals with acute stroke and aphasia, 25 individuals with acute stroke but no aphasia, 16 individuals with chronic post-stroke aphasia, and 14 healthy controls. The patients with chronic post-stroke aphasia were tested 3 times each and scored independently by 2 raters to establish test-retest and inter-rater reliability. The Western Aphasia Battery (WAB) was also administered to these patients to assess concurrent validity. We found that all QAB summary measures were sensitive to aphasic deficits in the two groups with aphasia. All measures showed good or excellent test-retest reliability (overall summary measure: intraclass correlation coefficient (ICC) = 0.98), and excellent inter-rater reliability (overall summary measure: ICC = 0.99). Sensitivity and specificity for diagnosis of aphasia (relative to clinical impression) were 0.91 and 0.95 respectively. All QAB measures were highly correlated with corresponding WAB measures where available. Individual patients showed distinct profiles of spared and impaired function across different language domains. In sum, the QAB efficiently and reliably characterized individual profiles of language deficits.

  2. A quick aphasia battery for efficient, reliable, and multidimensional assessment of language function

    PubMed Central

    Eriksson, Dana K.; Schneck, Sarah M.; Lucanie, Jillian M.

    2018-01-01

    This paper describes a quick aphasia battery (QAB) that aims to provide a reliable and multidimensional assessment of language function in about a quarter of an hour, bridging the gap between comprehensive batteries that are time-consuming to administer, and rapid screening instruments that provide limited detail regarding individual profiles of deficits. The QAB is made up of eight subtests, each comprising sets of items that probe different language domains, vary in difficulty, and are scored with a graded system to maximize the informativeness of each item. From the eight subtests, eight summary measures are derived, which constitute a multidimensional profile of language function, quantifying strengths and weaknesses across core language domains. The QAB was administered to 28 individuals with acute stroke and aphasia, 25 individuals with acute stroke but no aphasia, 16 individuals with chronic post-stroke aphasia, and 14 healthy controls. The patients with chronic post-stroke aphasia were tested 3 times each and scored independently by 2 raters to establish test-retest and inter-rater reliability. The Western Aphasia Battery (WAB) was also administered to these patients to assess concurrent validity. We found that all QAB summary measures were sensitive to aphasic deficits in the two groups with aphasia. All measures showed good or excellent test-retest reliability (overall summary measure: intraclass correlation coefficient (ICC) = 0.98), and excellent inter-rater reliability (overall summary measure: ICC = 0.99). Sensitivity and specificity for diagnosis of aphasia (relative to clinical impression) were 0.91 and 0.95 respectively. All QAB measures were highly correlated with corresponding WAB measures where available. Individual patients showed distinct profiles of spared and impaired function across different language domains. In sum, the QAB efficiently and reliably characterized individual profiles of language deficits. PMID:29425241

  3. Creating Highly Reliable Accountable Care Organizations.

    PubMed

    Vogus, Timothy J; Singer, Sara J

    2016-12-01

    Accountable Care Organizations' (ACOs) pursuit of the triple aim of higher quality, lower cost, and improved population health has met with mixed results. To improve the design and implementation of ACOs we look to organizations that manage similarly complex, dynamic, and tightly coupled conditions while sustaining exceptional performance known as high-reliability organizations. We describe the key processes through which organizations achieve reliability, the leadership and organizational practices that enable it, and the role that professionals can play when charged with enacting it. Specifically, we present concrete practices and processes from health care organizations pursuing high-reliability and from early ACOs to illustrate how the triple aim may be met by cultivating mindful organizing, practicing reliability-enhancing leadership, and identifying and supporting reliability professionals. We conclude by proposing a set of research questions to advance the study of ACOs and high-reliability research. © The Author(s) 2016.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vanderwiel, Scott A; Wilson, Alyson G; Graves, Todd L

    Both the U. S. Department of Defense (DoD) and Department of Energy (DOE) maintain weapons stockpiles: items like bullets, missiles and bombs that have already been produced and are being stored until needed. Ideally, these stockpiles maintain high reliability over time. To assess reliability, a surveillance program is implemented, where units are periodically removed from the stockpile and tested. The most definitive tests typically destroy the weapons so a given unit is tested only once. Surveillance managers need to decide how many units should be tested, how often they should be tested, what tests should be done, and how themore » resulting data are used to estimate the stockpile's current and future reliability. These issues are particularly critical from a planning perspective: given what has already been observed and our understanding of the mechanisms of stockpile aging, what is an appropriate and cost-effective surveillance program? Surveillance programs are costly, broad, and deep, especially in the DOE, where the US nuclear weapons surveillance program must 'ensure, through various tests, that the reliability of nuclear weapons is maintained' in the absence of full-system testing (General Accounting Office, 1996). The DOE program consists primarily of three types of tests: nonnuclear flight tests, that involve the actual dropping or launching of a weapon from which the nuclear components have been removed; and nonnuclear and nuclear systems laboratory tests, which detect defects due to aging, manufacturing, and design of the nonnuclear and nuclear portions of the weapons. Fully integrated analysis of the suite of nuclear weapons surveillance data is an ongoing area of research (Wilson et al., 2007). This paper introduces a simple model that captures high-level features of stockpile reliability over time and can be used to answer broad policy questions about surveillance programs. Our intention is to provide a framework that generates tractable answers that integrate expert knowledge and high-level summaries of surveillance data to allow decision-making about appropriate trade-offs between the cost of data and the precision of stockpile reliability estimates.« less

  5. The NASA Advanced Space Power Systems Project

    NASA Technical Reports Server (NTRS)

    Mercer, Carolyn R.; Hoberecht, Mark A.; Bennett, William R.; Lvovich, Vadim F.; Bugga, Ratnakumar

    2015-01-01

    The goal of the NASA Advanced Space Power Systems Project is to develop advanced, game changing technologies that will provide future NASA space exploration missions with safe, reliable, light weight and compact power generation and energy storage systems. The development effort is focused on maturing the technologies from a technology readiness level of approximately 23 to approximately 56 as defined in the NASA Procedural Requirement 7123.1B. Currently, the project is working on two critical technology areas: High specific energy batteries, and regenerative fuel cell systems with passive fluid management. Examples of target applications for these technologies are: extending the duration of extravehicular activities (EVA) with high specific energy and energy density batteries; providing reliable, long-life power for rovers with passive fuel cell and regenerative fuel cell systems that enable reduced system complexity. Recent results from the high energy battery and regenerative fuel cell technology development efforts will be presented. The technical approach, the key performance parameters and the technical results achieved to date in each of these new elements will be included. The Advanced Space Power Systems Project is part of the Game Changing Development Program under NASAs Space Technology Mission Directorate.

  6. Developing an assessment of fire-setting to guide treatment in secure settings: the St Andrew's Fire and Arson Risk Instrument (SAFARI).

    PubMed

    Long, Clive G; Banyard, Ellen; Fulton, Barbara; Hollin, Clive R

    2014-09-01

    Arson and fire-setting are highly prevalent among patients in secure psychiatric settings but there is an absence of valid and reliable assessment instruments and no evidence of a significant approach to intervention. To develop a semi-structured interview assessment specifically for fire-setting to augment structured assessments of risk and need. The extant literature was used to frame interview questions relating to the antecedents, behaviour and consequences necessary to formulate a functional analysis. Questions also covered readiness to change, fire-setting self-efficacy, the probability of future fire-setting, barriers to change, and understanding of fire-setting behaviour. The assessment concludes with indications for assessment and a treatment action plan. The inventory was piloted with a sample of women in secure care and was assessed for comprehensibility, reliability and validity. Staff rated the St Andrews Fire and Risk Instrument (SAFARI) as acceptable to patients and easy to administer. SAFARI was found to be comprehensible by over 95% of the general population, to have good acceptance, high internal reliability, substantial test-retest reliability and validity. SAFARI helps to provide a clear explanation of fire-setting in terms of the complex interplay of antecedents and consequences and facilitates the design of an individually tailored treatment programme in sympathy with a cognitive-behavioural approach. Further studies are needed to verify the reliability and validity of SAFARI with male populations and across settings.

  7. Development of an intensive care unit resource assessment survey for the care of critically ill patients in resource-limited settings.

    PubMed

    Leligdowicz, Aleksandra; Bhagwanjee, Satish; Diaz, Janet V; Xiong, Wei; Marshall, John C; Fowler, Robert A; Adhikari, Neill Kj

    2017-04-01

    Capacity to provide critical care in resource-limited settings is poorly understood because of lack of data about resources available to manage critically ill patients. Our objective was to develop a survey to address this issue. We developed and piloted a cross-sectional self-administered survey in 9 resource-limited countries. The survey consisted of 8 domains; specific items within domains were modified from previously developed survey tools. We distributed the survey by e-mail to a convenience sample of health care providers responsible for providing care to critically ill patients. We assessed clinical sensibility and test-retest reliability. Nine of 15 health care providers responded to the survey on 2 separate occasions, separated by 2 to 4 weeks. Clinical sensibility was high (3.9-4.9/5 on assessment tool). Test-retest reliability for questions related to resource availability was acceptable (intraclass correlation coefficient, 0.94; 95% confidence interval, 0.75-0.99; mean (SD) of weighted κ values = 0.67 [0.19]). The mean (SD) time for survey completion survey was 21 (16) minutes. A reliable cross-sectional survey of available resources to manage critically ill patients can be feasibly administered to health care providers in resource-limited settings. The survey will inform future research focusing on access to critical care where it is poorly described but urgently needed. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Improving the Test-Retest Reliability of Resting State fMRI by Removing the Impact of Sleep.

    PubMed

    Wang, Jiahui; Han, Junwei; Nguyen, Vinh T; Guo, Lei; Guo, Christine C

    2017-01-01

    Resting state functional magnetic resonance imaging (rs-fMRI) provides a powerful tool to examine large-scale neural networks in the human brain and their disturbances in neuropsychiatric disorders. Thanks to its low demand and high tolerance, resting state paradigms can be easily acquired from clinical population. However, due to the unconstrained nature, resting state paradigm is associated with excessive head movement and proneness to sleep. Consequently, the test-retest reliability of rs-fMRI measures is moderate at best, falling short of widespread use in the clinic. Here, we characterized the effect of sleep on the test-retest reliability of rs-fMRI. Using measures of heart rate variability (HRV) derived from simultaneous electrocardiogram (ECG) recording, we identified portions of fMRI data when subjects were more alert or sleepy, and examined their effects on the test-retest reliability of functional connectivity measures. When volumes of sleep were excluded, the reliability of rs-fMRI is significantly improved, and the improvement appears to be general across brain networks. The amount of improvement is robust with the removal of as much as 60% volumes of sleepiness. Therefore, test-retest reliability of rs-fMRI is affected by sleep and could be improved by excluding volumes of sleepiness as indexed by HRV. Our results suggest a novel and practical method to improve test-retest reliability of rs-fMRI measures.

  9. TRIDENT II (D-5) Strategic Weapon System Guide for Potential Subcontractors.

    DTIC Science & Technology

    1982-01-01

    pattern. Usually high technology item subcontracts are the first selected, This is followed by crit- ical, special long-lead time, common, and...performance. These disciplines provide the program with a definitive approach to maintaining high standards of reliability and readiness for weapon system...missile itself will be increased in length and diameter.. The range of the missile will be enhanced, and it will carry an increased payload. Energy

  10. Capacity fade in high energy silicon-graphite electrodes for lithium-ion batteries

    DOE PAGES

    Dose, W. M.; Piernas-Munoz, M. J.; Maroni, V. A.; ...

    2018-02-09

    A silicon-graphite blended anode is paired with a high capacity LiFePO 4 reference/counter electrode to track irreversibility and lithium inventory. The LiFePO 4 electrode provides a reliable, flat potential for dQ dV -1 analysis of Li xSi and Li xC electrochemical reactions. We can relate this electrochemistry to the morphological and physical changes taking place.

  11. High Throughput Determination of Tetramine in Drinking ...

    EPA Pesticide Factsheets

    Report The sampling and analytical procedure (SAP) presented herein, describes a method for the high throughput determination of tetramethylene disulfotetramine in drinking water by solid phase extraction and isotope dilution gas chromatography/mass spectrometry. This method, which will be included in the SAM, is expected to provide the Water Laboratory Alliance, as part of EPA’s Environmental Response Laboratory Network, with a more reliable and faster means of analyte collection and measurement.

  12. Capacity fade in high energy silicon-graphite electrodes for lithium-ion batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dose, W. M.; Piernas-Munoz, M. J.; Maroni, V. A.

    A silicon-graphite blended anode is paired with a high capacity LiFePO 4 reference/counter electrode to track irreversibility and lithium inventory. The LiFePO 4 electrode provides a reliable, flat potential for dQ dV -1 analysis of Li xSi and Li xC electrochemical reactions. We can relate this electrochemistry to the morphological and physical changes taking place.

  13. A rater training protocol to assess team performance.

    PubMed

    Eppich, Walter; Nannicelli, Anna P; Seivert, Nicholas P; Sohn, Min-Woong; Rozenfeld, Ranna; Woods, Donna M; Holl, Jane L

    2015-01-01

    Simulation-based methodologies are increasingly used to assess teamwork and communication skills and provide team training. Formative feedback regarding team performance is an essential component. While effective use of simulation for assessment or training requires accurate rating of team performance, examples of rater-training programs in health care are scarce. We describe our rater training program and report interrater reliability during phases of training and independent rating. We selected an assessment tool shown to yield valid and reliable results and developed a rater training protocol with an accompanying rater training handbook. The rater training program was modeled after previously described high-stakes assessments in the setting of 3 facilitated training sessions. Adjacent agreement was used to measure interrater reliability between raters. Nine raters with a background in health care and/or patient safety evaluated team performance of 42 in-situ simulations using post-hoc video review. Adjacent agreement increased from the second training session (83.6%) to the third training session (85.6%) when evaluating the same video segments. Adjacent agreement for the rating of overall team performance was 78.3%, which was added for the third training session. Adjacent agreement was 97% 4 weeks posttraining and 90.6% at the end of independent rating of all simulation videos. Rater training is an important element in team performance assessment, and providing examples of rater training programs is essential. Articulating key rating anchors promotes adequate interrater reliability. In addition, using adjacent agreement as a measure allows differentiation between high- and low-performing teams on video review. © 2015 The Alliance for Continuing Education in the Health Professions, the Society for Academic Continuing Medical Education, and the Council on Continuing Medical Education, Association for Hospital Medical Education.

  14. Ejectors of power plants turbine units efficiency and reliability increasing

    NASA Astrophysics Data System (ADS)

    Aronson, K. E.; Ryabchikov, A. Yu.; Kuptsov, V. K.; Murmanskii, I. B.; Brodov, Yu. M.; Zhelonkin, N. V.; Khaet, S. I.

    2017-11-01

    The functioning of steam turbines condensation systems influence on the efficiency and reliability of a power plant a lot. At the same time, the condensation system operating is provided by basic ejectors, which maintain the vacuum level in the condenser. Development of methods of efficiency and reliability increasing for ejector functioning is an actual problem of up-to-date power engineering. In the paper there is presented statistical analysis of ejector breakdowns, revealed during repairing processes, the influence of such damages on the steam turbine operating reliability. It is determined, that 3% of steam turbine equipment breakdowns are the ejector breakdowns. At the same time, about 7% of turbine breakdowns are caused by different ejector malfunctions. Developed and approved design solutions, which can increase the ejector functioning indexes, are presented. Intercoolers are designed in separated cases, so the air-steam mixture can’t move from the high-pressure zones to the low-pressure zones and the maintainability of the apparatuses is increased. By U-type tubes application, the thermal expansion effect of intercooler tubes is compensated and the heat-transfer area is increased. By the applied nozzle fixing construction, it is possible to change the distance between a nozzle and a mixing chamber (nozzle exit position) for operating performance optimization. In operating conditions there are provided experimental researches of more than 30 serial ejectors and also high-efficient 3-staged ejector EPO-3-80, designed by authors. The measurement scheme of the designed ejector includes 21 indicator. The results of experimental tests with different nozzle exit positions of the ejector EPO-3-80 stream devices are presented. The pressure of primary stream (water steam) is optimized. Experimental data are well-approved by the calculation results.

  15. Extremely Durable, Flexible Supercapacitors with Greatly Improved Performance at High Temperatures.

    PubMed

    Kim, Sung-Kon; Kim, Hae Jin; Lee, Jong-Chan; Braun, Paul V; Park, Ho Seok

    2015-08-25

    The reliability and durability of energy storage devices are as important as their essential characteristics (e.g., energy and power density) for stable power output and long lifespan and thus much more crucial under harsh conditions. However, energy storage under extreme conditions is still a big challenge because of unavoidable performance decays and the inevitable damage of components. Here, we report high-temperature operating, flexible supercapacitors (f-SCs) that can provide reliable power output and extreme durability under severe electrochemical, mechanical, and thermal conditions. The outstanding capacitive features (e.g., ∼40% enhancement of the rate capability and a maximum capacitances of 170 F g(-1) and 18.7 mF cm(-2) at 160 °C) are attributed to facilitated ion transport at elevated temperatures. Under high-temperature operation and/or a flexibility test in both static and dynamic modes at elevated temperatures >100 °C, the f-SCs showed extreme long-term stability of 100000 cycles (>93% of initial capacitance value) and mechanical durability after hundreds of bending cycles (at bend angles of 60-180°). Even at 120 °C, the versatile design of tandem serial and parallel f-SCs was demonstrated to provide both desirable energy and power requirements at high temperatures.

  16. Reliability and validity of bilateral ankle accelerometer algorithms for activity recognition and walking speed after stroke.

    PubMed

    Dobkin, Bruce H; Xu, Xiaoyu; Batalin, Maxim; Thomas, Seth; Kaiser, William

    2011-08-01

    Outcome measures of mobility for large stroke trials are limited to timed walks for short distances in a laboratory, step counters and ordinal scales of disability and quality of life. Continuous monitoring and outcome measurements of the type and quantity of activity in the community would provide direct data about daily performance, including compliance with exercise and skills practice during routine care and clinical trials. Twelve adults with impaired ambulation from hemiparetic stroke and 6 healthy controls wore triaxial accelerometers on their ankles. Walking speed for repeated outdoor walks was determined by machine-learning algorithms and compared to a stopwatch calculation of speed for distances not known to the algorithm. The reliability of recognizing walking, exercise, and cycling by the algorithms was compared to activity logs. A high correlation was found between stopwatch-measured outdoor walking speed and algorithm-calculated speed (Pearson coefficient, 0.98; P=0.001) and for repeated measures of algorithm-derived walking speed (P=0.01). Bouts of walking >5 steps, variations in walking speed, cycling, stair climbing, and leg exercises were correctly identified during a day in the community. Compared to healthy subjects, those with stroke were, as expected, more sedentary and slower, and their gait revealed high paretic-to-unaffected leg swing ratios. Test-retest reliability and concurrent and construct validity are high for activity pattern-recognition Bayesian algorithms developed from inertial sensors. This ratio scale data can provide real-world monitoring and outcome measurements of lower extremity activities and walking speed for stroke and rehabilitation studies.

  17. An all-solid-state CO2 laser driver

    NASA Astrophysics Data System (ADS)

    Birx, Daniel

    1991-03-01

    New, all-solid-state pulse generators are described which meet military requirements for an efficient, reliable pulsed power source to drive a space based CO2 laser. These SCR-commutated, nonlinear magnetic pulse compressors are fully-compatible with the present Spectra Technologies laser head design planned for use on LOWKATER. By employing SCRs rather than thyratron commutators, these pulsers should provide a significant increase in reliability over the current generation of pulsed power drivers. The first pulser which was designed and constructed was denoted COLD-I. COLD-I was designed to meet the original LOWKATER specifications and delivered at 150 joule, 20 kV pulse into a laser load at 10 to 20 Hz repetition rate. The second pulser, denoted COLD-II, was designed to provide a 45 joule, 500 nsec duration pulse at a voltage of 20 kV and a repetition rate of 1 kHz peak and 50 to 100 Hz average. The electrical efficiency was measured to be 80 percent with an input drive of 500 VDC. This pulse served as a design verification testbed for a third pulser, presently designed but not constructed and denoted COLD-III. COLD-III would be capable of producing 36 joules at the same pulse length and repetition rate at voltages of 20 kV. The Phase-II effort was a high risk, high payoff effort aimed at developing a light weight, high reliability RF power source for advanced RF CO2 laser heads under development. COLD-IV a Branched Magnetic RF Nonlinear Magnetic Pulse Compressor was built as a bread

  18. Teaching DSM-III to clinicians. Some problems of the DSM-III system reducing reliability, using the diagnosis and classification of depressive disorders as an example.

    PubMed

    Malt, U F

    1986-01-01

    Experiences from teaching DSM-III to more than three hundred Norwegian psychiatrists and clinical psychologists suggest that reliable DSM-III diagnoses can be achieved within a few hours training with reference to the decision trees and the diagnostic criteria only. The diagnoses provided are more reliable than the corresponding ICD diagnoses which the participants were more familiar with. The three main sources of reduced reliability of the DSM-III diagnoses are related to: poor knowledge of the criteria which often is connected with failure of obtaining diagnostic key information during the clinical interview; unfamiliar concepts and vague or ambiguous criteria. The two first issues are related to the quality of the teaching of DSM-III. The third source of reduced reliability reflects unsolved validity issues. By using the classification of five affective case stories as examples, these sources of diagnostic pitfalls, reducing reliability and ways to overcome these problems when teaching the DSM-III system, are discussed. It is concluded that the DSM-III system of classification is easy to teach and that the system is superior to other classification systems available from a reliability point of view. The current version of the DSM-III system, however, partly owes a high degree of reliability to broad and heterogeneous diagnostic categories like the concept major depression, which may have questionable validity. Thus, the future revisions of the DSM-III system should, above all, address the issue of validity.

  19. Preliminary validation and reliability of the Short Form Chronic Respiratory Disease Questionnaire in a lung cancer population.

    PubMed

    Charalambous, A; Molassiotis, A

    2017-01-01

    The Short Form Chronic Respiratory Questionnaire (SF-CRQ) is frequently used in patients with obstructive pulmonary disease and it has demonstrated excellent psychometric properties. Since there is no psychometric information for its use with lung cancer patients, this study explored its validity and reliability in this population. Forty-six patients were assessed at two time points (with a 4-week interval) using the SF-CRQ, the modified Borg Scale, five numerical rating scales related to Perceived Severity of Breathlessness, and the Hospital Anxiety and Depression Scale. Internal consistency reliability was investigated by Cronbach's alpha reliability coefficient, test-retest reliability by Spearman-Brown reliability coefficient (P), content validity as well as convergent validity by Pearson's correlation coefficient between the SF-CRQ, and the conceptual similar scales mentioned above were explored. A principal component factor analysis was performed. The internal consistency was high [α = 0.88 (baseline) and 0.91 (after 1 month)]. The SF-CRQ had good stability with test-retest reliability ranging from r = 0.64 to 0.78, P < 0.001. Factor analysis suggests a single construct in this population. The preliminary data analyses supported the convergent, content, and construct validity of the SF-CRQ providing promising evidence that this can be a valid and reliable instrument for the assessment of quality of life related to breathlessness in lung cancer patients. © 2015 John Wiley & Sons Ltd.

  20. Discharge reliability in ablative pulsed plasma thrusters

    NASA Astrophysics Data System (ADS)

    Wu, Zhiwen; Sun, Guorui; Yuan, Shiyue; Huang, Tiankun; Liu, Xiangyang; Xie, Kan; Wang, Ningfei

    2017-08-01

    Discharge reliability is typically neglected in low-ignition-cycle ablative pulsed plasma thrusters (APPTs). In this study, the discharge reliability of an APPT is assessed analytically and experimentally. The goals of this study are to better understand the ignition characteristics and to assess the accuracy of the analytical method. For each of six sets of operating conditions, 500 tests of a parallel-plate APPT with a coaxial semiconductor spark plug are conducted. The discharge voltage and current are measured with a high-voltage probe and a Rogowski coil, respectively, to determine whether the discharge is successful. Generally, the discharge success rate increases as the discharge voltage increases, and it decreases as the electrode gap and the number of ignitions increases. The theoretical analysis and the experimental results are reasonably consistent. This approach provides a reference for designing APPTs and improving their stability.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlson, J.J.; Bouchard, A.M.; Osbourn, G.C.

    Future generation automated human biometric identification and verification will require multiple features/sensors together with internal and external information sources to achieve high performance, accuracy, and reliability in uncontrolled environments. The primary objective of the proposed research is to develop a theoretical and practical basis for identifying and verifying people using standoff biometric features that can be obtained with minimal inconvenience during the verification process. The basic problem involves selecting sensors and discovering features that provide sufficient information to reliably verify a person`s identity under the uncertainties caused by measurement errors and tactics of uncooperative subjects. A system was developed formore » discovering hand, face, ear, and voice features and fusing them to verify the identity of people. The system obtains its robustness and reliability by fusing many coarse and easily measured features into a near minimal probability of error decision algorithm.« less

  2. HiRel: Hybrid Automated Reliability Predictor (HARP) integrated reliability tool system, (version 7.0). Volume 1: HARP introduction and user's guide

    NASA Technical Reports Server (NTRS)

    Bavuso, Salvatore J.; Rothmann, Elizabeth; Dugan, Joanne Bechta; Trivedi, Kishor S.; Mittal, Nitin; Boyd, Mark A.; Geist, Robert M.; Smotherman, Mark D.

    1994-01-01

    The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed to be compatible with most computing platforms and operating systems, and some programs have been beta tested, within the aerospace community for over 8 years. Volume 1 provides an introduction to the HARP program. Comprehensive information on HARP mathematical models can be found in the references.

  3. Reliability of the Melbourne assessment of unilateral upper limb function.

    PubMed

    Randall, M; Carlin, J B; Chondros, P; Reddihough, D

    2001-11-01

    This study examines the reliability of the Melbourne Assessment of Unilateral Upper Limb Function: a quantitative test of quality of movement in children with neurological impairment. The assessment was administered to 20 children aged from 5 to 16 years (mean age 9 years 10 months, SD 2 years 10 months) who had various types and degrees of cerebral palsy (CP). The performances of the 20 children during assessment were videotaped for subsequent scoring by 15 occupational therapists. Scores were analyzed for internal consistency of test items, inter- and intrarater reliability of scorings of the same videotapes, and test-retest reliability using repeat videotaping. Results revealed very high internal consistency of test items (alpha=0.96), moderate to high agreement both within and between raters for all test items (intraclass correlations of at least 0.7) apart from item 16 (hand to mouth and down), and high interrater reliability (0.95) and intrarater reliability (0.97) for total test scores. Test-retest results revealed moderate to high intrarater reliability for item totals (mean of 0.83 and 0.79) for each rater and high reliability for test totals (0.98 and 0.97). These findings indicate that the Melbourne Assessment of Unilateral Upper Limb Function is a reliable tool for measuring the quality of unilateral upper-limb movement in children with CP.

  4. Analysis of fatigue reliability for high temperature and high pressure multi-stage decompression control valve

    NASA Astrophysics Data System (ADS)

    Yu, Long; Xu, Juanjuan; Zhang, Lifang; Xu, Xiaogang

    2018-03-01

    Based on stress-strength interference theory to establish the reliability mathematical model for high temperature and high pressure multi-stage decompression control valve (HMDCV), and introduced to the temperature correction coefficient for revising material fatigue limit at high temperature. Reliability of key dangerous components and fatigue sensitivity curve of each component are calculated and analyzed by the means, which are analyzed the fatigue life of control valve and combined with reliability theory of control valve model. The impact proportion of each component on the control valve system fatigue failure was obtained. The results is shown that temperature correction factor makes the theoretical calculations of reliability more accurate, prediction life expectancy of main pressure parts accords with the technical requirements, and valve body and the sleeve have obvious influence on control system reliability, the stress concentration in key part of control valve can be reduced in the design process by improving structure.

  5. Measuring treatment process in cognitive-behavioral and interactional group therapies for adolescent substance abusers.

    PubMed

    Kaminer, Y; Blitz, C; Burleson, J A; Kadden, R M; Rounsaville, B J

    1998-07-01

    The state of the art for treatment efficacy studies now requires manual guided treatments and tests of therapist adherence. This report provides findings regarding adherence assessment of therapists participating in an investigation of treatment matching in adolescent substance abusers. The Group Sessions Rating Scale (GSRS), a group-therapy process measure, was studied to determine its appropriateness for assessing group treatment of adolescents with a) substance use disorders (SUD), b) interrater reliability, c) internal consistency, and d) ability to discriminate the active ingredients of cognitive-behavioral therapy (CBT) from interactional therapy (IT). Interrater reliabilities were moderate to high, with those for CBT generally higher than those for IT. Internal consistency of CBT items was moderate, whereas those of IT were moderately high. Discriminability between the two treatment modalities was high. The frequency of active ingredients was generally therapy-specific: high for the relevant and low for the nonrelevant therapeutic modality items. The GSRS was found to be effective in the measurement of treatment process in adolescents with SUD.

  6. Development of in-situ high-voltage and high-temperature stressing capability on atomic force microscopy platform

    DOE PAGES

    Xiao, Chuanxiao; Jiang, Chun-Sheng; Johnston, Steve; ...

    2017-10-18

    Reliability has become an increasingly important issue as photovoltaic technologies mature. However, researching reliability at the nanometer scale is in its infancy; in particular, in-situ studies have not been reported to date. Here, to investigate potential-induced degradation (PID) of solar cell modules, we have developed an in-situ stressing capability with applied high voltage (HV) and high temperature (HT) on an atomic force microscopy (AFM) platform. We designed a sample holder to simultaneously accommodate 1000-V HV and 200 degrees C HT stressing. Three technical challenges have been overcome along with the development: thermal drift at HT, HV interference with measurement, andmore » arc discharge caused by HV. We demonstrated no observable measurement artifact under the stress conditions. Based on our in-situ stressing AFM, Kelvin probe force microscopy potential imaging revealed the evolution of electrical potential across the junction along with the PID stressing time, which provides vital information to further study the PID mechanism.« less

  7. A modular and compact portable mini-endstation for high-precision, high-speed fixed target serial crystallography at FEL and synchrotron sources

    DOE PAGES

    Sherrell, Darren A.; Foster, Andrew J.; Hudson, Lee; ...

    2015-01-01

    The design and implementation of a compact and portable sample alignment system suitable for use at both synchrotron and free-electron laser (FEL) sources and its performance are described. The system provides the ability to quickly and reliably deliver large numbers of samples using the minimum amount of sample possible, through positioning of fixed target arrays into the X-ray beam. The combination of high-precision stages, high-quality sample viewing, a fast controller and a software layer overcome many of the challenges associated with sample alignment. A straightforward interface that minimizes setup and sample changeover time as well as simplifying communication with themore » stages during the experiment is also described, together with an intuitive naming convention for defining, tracking and locating sample positions. Lastly, the setup allows the precise delivery of samples in predefined locations to a specific position in space and time, reliably and simply.« less

  8. Development of in-situ high-voltage and high-temperature stressing capability on atomic force microscopy platform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xiao, Chuanxiao; Jiang, Chun-Sheng; Johnston, Steve

    Reliability has become an increasingly important issue as photovoltaic technologies mature. However, researching reliability at the nanometer scale is in its infancy; in particular, in-situ studies have not been reported to date. Here, to investigate potential-induced degradation (PID) of solar cell modules, we have developed an in-situ stressing capability with applied high voltage (HV) and high temperature (HT) on an atomic force microscopy (AFM) platform. We designed a sample holder to simultaneously accommodate 1000-V HV and 200 degrees C HT stressing. Three technical challenges have been overcome along with the development: thermal drift at HT, HV interference with measurement, andmore » arc discharge caused by HV. We demonstrated no observable measurement artifact under the stress conditions. Based on our in-situ stressing AFM, Kelvin probe force microscopy potential imaging revealed the evolution of electrical potential across the junction along with the PID stressing time, which provides vital information to further study the PID mechanism.« less

  9. Modeling and Simulation Reliable Spacecraft On-Board Computing

    NASA Technical Reports Server (NTRS)

    Park, Nohpill

    1999-01-01

    The proposed project will investigate modeling and simulation-driven testing and fault tolerance schemes for Spacecraft On-Board Computing, thereby achieving reliable spacecraft telecommunication. A spacecraft communication system has inherent capabilities of providing multipoint and broadcast transmission, connectivity between any two distant nodes within a wide-area coverage, quick network configuration /reconfiguration, rapid allocation of space segment capacity, and distance-insensitive cost. To realize the capabilities above mentioned, both the size and cost of the ground-station terminals have to be reduced by using reliable, high-throughput, fast and cost-effective on-board computing system which has been known to be a critical contributor to the overall performance of space mission deployment. Controlled vulnerability of mission data (measured in sensitivity), improved performance (measured in throughput and delay) and fault tolerance (measured in reliability) are some of the most important features of these systems. The system should be thoroughly tested and diagnosed before employing a fault tolerance into the system. Testing and fault tolerance strategies should be driven by accurate performance models (i.e. throughput, delay, reliability and sensitivity) to find an optimal solution in terms of reliability and cost. The modeling and simulation tools will be integrated with a system architecture module, a testing module and a module for fault tolerance all of which interacting through a centered graphical user interface.

  10. A Report on Simulation-Driven Reliability and Failure Analysis of Large-Scale Storage Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wan, Lipeng; Wang, Feiyi; Oral, H. Sarp

    High-performance computing (HPC) storage systems provide data availability and reliability using various hardware and software fault tolerance techniques. Usually, reliability and availability are calculated at the subsystem or component level using limited metrics such as, mean time to failure (MTTF) or mean time to data loss (MTTDL). This often means settling on simple and disconnected failure models (such as exponential failure rate) to achieve tractable and close-formed solutions. However, such models have been shown to be insufficient in assessing end-to-end storage system reliability and availability. We propose a generic simulation framework aimed at analyzing the reliability and availability of storagemore » systems at scale, and investigating what-if scenarios. The framework is designed for an end-to-end storage system, accommodating the various components and subsystems, their interconnections, failure patterns and propagation, and performs dependency analysis to capture a wide-range of failure cases. We evaluate the framework against a large-scale storage system that is in production and analyze its failure projections toward and beyond the end of lifecycle. We also examine the potential operational impact by studying how different types of components affect the overall system reliability and availability, and present the preliminary results« less

  11. An empirical look at the Defense Mechanism Test (DMT): reliability and construct validity.

    PubMed

    Ekehammar, Bo; Zuber, Irena; Konstenius, Marja-Liisa

    2005-07-01

    Although the Defense Mechanism Test (DMT) has been in use for almost half a century, there are still quite contradictory views about whether it is a reliable instrument, and if so, what it really measures. Thus, based on data from 39 female students, we first examined DMT inter-coder reliability by analyzing the agreement among trained judges in their coding of the same DMT protocols. Second, we constructed a "parallel" photographic picture that retained all structural characteristic of the original and analyzed DMT parallel-test reliability. Third, we examined the construct validity of the DMT by (a) employing three self-report defense-mechanism inventories and analyzing the intercorrelations between DMT defense scores and corresponding defenses in these instruments, (b) studying the relationships between DMT responses and scores on trait and state anxiety, and (c) relating DMT-defense scores to measures of self-esteem. The main results showed that the DMT can be coded with high reliability by trained coders, that the parallel-test reliability is unsatisfactory compared to traditional psychometric standards, that there is a certain generalizability in the number of perceptual distortions that people display from one picture to another, and that the construct validation provided meager empirical evidence for the conclusion that the DMT measures what it purports to measure, that is, psychological defense mechanisms.

  12. Deformation of Cases in High Capacitance Value Wet Tantalum Capacitors under Environmental Stresses

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander

    2016-01-01

    Internal gas pressure in hermetic wet tantalum capacitors is created by air, electrolyte vapor, and gas generated by electrochemical reactions at the electrodes. This pressure increases substantially with temperature and time of operation due to excessive leakage currents. Deformation of the case occurs when the internal pressure exceeds pressure of the environments and can raise significantly when a part operates in space. Contrary to the cylinder case wet tantalum capacitors that have external sealing by welding and internal sealing provided by the Teflon bushing and crimping of the case, no reliable internal sealing exists in the button case capacitors. Single seal design capacitors are used for high capacitance value wet tantalum capacitors manufactured per DLA L&M drawings #04003, 04005, and 10011, and require additional analysis to assure their reliable application in space systems. In this work, leakage currents and case deformation of button case capacitors were measured during different environmental test conditions. Recommendations for derating, screening and qualification testing are given. This work is a continuation of a series of NEPP reports related to quality and reliability of wet tantalum capacitors.

  13. Comparison of sampling methodologies for nutrient monitoring in streams: uncertainties, costs and implications for mitigation

    NASA Astrophysics Data System (ADS)

    Audet, J.; Martinsen, L.; Hasler, B.; de Jonge, H.; Karydi, E.; Ovesen, N. B.; Kronvang, B.

    2014-07-01

    Eutrophication of aquatic ecosystems caused by excess concentrations of nitrogen and phosphorus may have harmful consequences for biodiversity and poses a health risk to humans via the water supplies. Reduction of nitrogen and phosphorus losses to aquatic ecosystems involves implementation of costly measures, and reliable monitoring methods are therefore essential to select appropriate mitigation strategies and to evaluate their effects. Here, we compare the performances and costs of three methodologies for the monitoring of nutrients in rivers: grab sampling, time-proportional sampling and passive sampling using flow proportional samplers. Assuming time-proportional sampling to be the best estimate of the "true" nutrient load, our results showed that the risk of obtaining wrong total nutrient load estimates by passive samplers is high despite similar costs as the time-proportional sampling. Our conclusion is that for passive samplers to provide a reliable monitoring alternative, further development is needed. Grab sampling was the cheapest of the three methods and was more precise and accurate than passive sampling. We conclude that although monitoring employing time-proportional sampling is costly, its reliability precludes unnecessarily high implementation expenses.

  14. Comparison of sampling methodologies for nutrient monitoring in streams: uncertainties, costs and implications for mitigation

    NASA Astrophysics Data System (ADS)

    Audet, J.; Martinsen, L.; Hasler, B.; de Jonge, H.; Karydi, E.; Ovesen, N. B.; Kronvang, B.

    2014-11-01

    Eutrophication of aquatic ecosystems caused by excess concentrations of nitrogen and phosphorus may have harmful consequences for biodiversity and poses a health risk to humans via water supplies. Reduction of nitrogen and phosphorus losses to aquatic ecosystems involves implementation of costly measures, and reliable monitoring methods are therefore essential to select appropriate mitigation strategies and to evaluate their effects. Here, we compare the performances and costs of three methodologies for the monitoring of nutrients in rivers: grab sampling; time-proportional sampling; and passive sampling using flow-proportional samplers. Assuming hourly time-proportional sampling to be the best estimate of the "true" nutrient load, our results showed that the risk of obtaining wrong total nutrient load estimates by passive samplers is high despite similar costs as the time-proportional sampling. Our conclusion is that for passive samplers to provide a reliable monitoring alternative, further development is needed. Grab sampling was the cheapest of the three methods and was more precise and accurate than passive sampling. We conclude that although monitoring employing time-proportional sampling is costly, its reliability precludes unnecessarily high implementation expenses.

  15. Reliability associated with the Roter Interaction Analysis System (RIAS) adapted for the telemedicine context.

    PubMed

    Nelson, Eve-Lynn; Miller, Edward Alan; Larson, Kiley A

    2010-01-01

    This study's purpose was to adapt the Roter Interaction Analysis System (RIAS) for telemedicine clinics and to investigate the adapted measure's reliability. The study also sought to better understand the volume of technology-related utterance in established telemedicine clinics and the feasibility of using the measure within the telemedicine setting. This initial evaluation is a first step before broadly using the adapted measure across technologies and raters. An expert panel adapted the RIAS for the telemedicine context. This involved accounting for all consultation participants (patient, provider, presenter, family) and adding technology-specific subcategories. Ten new and 36 follow-up telemedicine encounters were videotaped and double coded using the adapted RIAS. These consisted primarily of follow-up visits (78.0%) involving patients, providers, presenters, and other parties. Reliability was calculated for those categories with 15 or more utterances. Traditional RIAS categories related to socioemotional and task-focused clusters had fair to excellent levels of reliability in the telemedicine setting. Although there were too few utterances to calculate the reliability of the specific technology-related subcategories, the summary technology-related category proved reliable for patients, providers, and presenters. Overall patterns seen in traditional patient-provider interactions were observed, with the number of provider utterances far exceeding patient, presenter, and family utterances, and few technology-specific utterances. The traditional RIAS is reliable when applied across multiple participants in the telemedicine context. Reliability of technology-related subcategories could not be evaluated; however, the aggregate technology-related cluster was found to be reliable and may be especially relevant in understanding communication patterns with patients new to the telemedicine setting. Use of the RIAS instrument is encouraged to facilitate comparison between traditional, face-to-face clinics and telemedicine; among diverse consultation mediums and technologies; and across different specialties. Future research is necessary to further investigate the reliability and validity of adding technology-related subcategories to the RIAS. The limited number of technology-related utterances, however, implies a certain degree of comfort with two-way interactive video consultation among study participants. Telemedicine continues to increase access to healthcare. The technology-related categories of the adapted RIAS were reliable when aggregated, thereby providing a tool to better understand how telemedicine affects provider-patient communication and outcomes.

  16. Safety in surgery: is selection the missing link?

    PubMed

    Paice, Alistair G; Aggarwal, Rajesh; Darzi, Ara

    2010-09-01

    Health care providers comprise an example of a "high risk organization." Safety failings within these organizations have the potential to cause significant public harm. Significant safety improvements in other high risk organizations such as the aviation industry have led to the concept of a high reliability organization (HRO)--a high risk organization that has enjoyed a prolonged safety record. A strong organizational culture is common to all successful HROs, encompassing powerful systems of selection and training. Aircrew selection processes provide a good example of this and are examined in detail in this article using the Royal Air Force process as an example. If the lessons of successful HROs are to be applied to health care organizations, candidate selection to specialties such as surgery must become more objective and robust. Other HROs can provide valuable lessons in how this may be approached.

  17. Validation of the Gifted Rating Scales–School Form in China

    PubMed Central

    Li, Huijun; Pfeiffer, Steven I.; Petscher, Yaacov; Kumtepe, Alper T.; Mo, Guofang

    2015-01-01

    The Gifted Rating Scales–School Form (GRS-S), a teacher-completed rating scale, is designed to identify five types of giftedness and motivation. This study examines the reliability and validity of a Chinese-translated version of the GRS-S with a sample of Chinese elementary and middle school students (N = 499). The Chinese GRSS was found to have high internal consistency. Results of the confirmatory factor analysis corroborated the six-factor solution of the original GRS-S. Comparison of the GRS-S scores and measures of academic performance provide preliminary support for the criterion validity of the Chinese-translated GRS-S. Significant age and gender differences on the Chinese GRS-S were found. Results provide preliminary support for the Chinese version of the GRS-S as a reliable and valid measure of giftedness for Chinese students. PMID:26346730

  18. Multi-objective optimization of GENIE Earth system models.

    PubMed

    Price, Andrew R; Myerscough, Richard J; Voutchkov, Ivan I; Marsh, Robert; Cox, Simon J

    2009-07-13

    The tuning of parameters in climate models is essential to provide reliable long-term forecasts of Earth system behaviour. We apply a multi-objective optimization algorithm to the problem of parameter estimation in climate models. This optimization process involves the iterative evaluation of response surface models (RSMs), followed by the execution of multiple Earth system simulations. These computations require an infrastructure that provides high-performance computing for building and searching the RSMs and high-throughput computing for the concurrent evaluation of a large number of models. Grid computing technology is therefore essential to make this algorithm practical for members of the GENIE project.

  19. Memory function and supportive technology

    PubMed Central

    Charness, Neil; Best, Ryan; Souders, Dustin

    2013-01-01

    Episodic and working memory processes show pronounced age-related decline, with other memory processes such as semantic, procedural, and metamemory less affected. Older adults tend to complain the most about prospective and retrospective memory failures. We introduce a framework for deciding how to mitigate memory decline using augmentation and substitution and discuss techniques that change the user, through mnemonics training, and change the tool or environment, by providing environmental support. We provide examples of low-tech and high-tech memory supports and discuss constraints on the utility of high-tech systems including effectiveness of devices, attitudes toward memory aids, and reliability of systems. PMID:24379752

  20. Graph Theoretical Analysis of Functional Brain Networks: Test-Retest Evaluation on Short- and Long-Term Resting-State Functional MRI Data

    PubMed Central

    Wang, Jin-Hui; Zuo, Xi-Nian; Gohel, Suril; Milham, Michael P.; Biswal, Bharat B.; He, Yong

    2011-01-01

    Graph-based computational network analysis has proven a powerful tool to quantitatively characterize functional architectures of the brain. However, the test-retest (TRT) reliability of graph metrics of functional networks has not been systematically examined. Here, we investigated TRT reliability of topological metrics of functional brain networks derived from resting-state functional magnetic resonance imaging data. Specifically, we evaluated both short-term (<1 hour apart) and long-term (>5 months apart) TRT reliability for 12 global and 6 local nodal network metrics. We found that reliability of global network metrics was overall low, threshold-sensitive and dependent on several factors of scanning time interval (TI, long-term>short-term), network membership (NM, networks excluding negative correlations>networks including negative correlations) and network type (NT, binarized networks>weighted networks). The dependence was modulated by another factor of node definition (ND) strategy. The local nodal reliability exhibited large variability across nodal metrics and a spatially heterogeneous distribution. Nodal degree was the most reliable metric and varied the least across the factors above. Hub regions in association and limbic/paralimbic cortices showed moderate TRT reliability. Importantly, nodal reliability was robust to above-mentioned four factors. Simulation analysis revealed that global network metrics were extremely sensitive (but varying degrees) to noise in functional connectivity and weighted networks generated numerically more reliable results in compared with binarized networks. For nodal network metrics, they showed high resistance to noise in functional connectivity and no NT related differences were found in the resistance. These findings provide important implications on how to choose reliable analytical schemes and network metrics of interest. PMID:21818285

  1. Development, reliability and validation of an infant mammalian penetration-aspiration scale

    PubMed Central

    Holman, Shaina Devi; Campbell-Malone, Regina; Ding, Peng; Gierbolini-Norat, Estela M.; Griffioen, Anne M.; Inokuchi, Haruhi; Lukasik, Stacey L.; German, Rebecca Z.

    2012-01-01

    A penetration-aspiration scale exists for assessing airway protection in adult videofluoroscopy and fiberoptic endoscopic swallowing studies, however no such scale exists for animal models. The aim of this study was threefold to 1) develop a Penetration-Aspiration Scale (PAS) for infant mammals, 2) test the scale’s intra- and inter-rater reliability, and 3) to validate the use of the scale for distinguishing between abnormal and normal animals. After discussion and reviewing many videos, the result was a 7-Point Infant Mammal PAS. Reliability was tested by having 5 judges score 90 swallows recorded with videofluoroscopy across two time points. In these videos, the frame rate was either 30 or 60 frames per second and the animals were either normal, had a unilateral superior laryngeal nerve (SLN) lesion, or had hard palate local anesthesia. The scale was validated by having one judge score videos of both normal and SLN lesioned pigs and testing the difference using a t-test. Raters had a high intra-rater (average kappa of 0.82, intraclass correlation coefficient (ICC)= 0.92) and high inter-rater reliability (average kappa of 0.68, ICC= 0.66). There was a significant difference in reliability for videos captured at 30 and 60 frames per second for scores of 3 and 7 (p<0.001). The scale was also validated for distinguishing between normal and abnormal pigs (p<0.001). Given the increasing number of animal studies using videofluoroscopy to study dysphagia, this scale provides a valid and reliable measure of airway protection during swallowing in infant pigs that will give these animal models increased translational significance. PMID:23129423

  2. Reliability of smartphone-based gait measurements for quantification of physical activity/inactivity levels

    PubMed Central

    Ebara, Takeshi; Azuma, Ryohei; Shoji, Naoto; Matsukawa, Tsuyoshi; Yamada, Yasuyuki; Akiyama, Tomohiro; Kurihara, Takahiro; Yamada, Shota

    2017-01-01

    Objectives: Objective measurements using built-in smartphone sensors that can measure physical activity/inactivity in daily working life have the potential to provide a new approach to assessing workers' health effects. The aim of this study was to elucidate the characteristics and reliability of built-in step counting sensors on smartphones for development of an easy-to-use objective measurement tool that can be applied in ergonomics or epidemiological research. Methods: To evaluate the reliability of step counting sensors embedded in seven major smartphone models, the 6-minute walk test was conducted and the following analyses of sensor precision and accuracy were performed: 1) relationship between actual step count and step count detected by sensors, 2) reliability between smartphones of the same model, and 3) false detection rates when sitting during office work, while riding the subway, and driving. Results: On five of the seven models, the inter-class correlations coefficient (ICC (3,1)) showed high reliability with a range of 0.956-0.993. The other two models, however, had ranges of 0.443-0.504 and the relative error ratios of the sensor-detected step count to the actual step count were ±48.7%-49.4%. The level of agreement between the same models was ICC (3,1): 0.992-0.998. The false detection rates differed between the sitting conditions. Conclusions: These results suggest the need for appropriate regulation of step counts measured by sensors, through means such as correction or calibration with a predictive model formula, in order to obtain the highly reliable measurement results that are sought in scientific investigation. PMID:28835575

  3. Repurposing a Benchtop Centrifuge for High-Throughput Single-Molecule Force Spectroscopy.

    PubMed

    Yang, Darren; Wong, Wesley P

    2018-01-01

    We present high-throughput single-molecule manipulation using a benchtop centrifuge, overcoming limitations common in other single-molecule approaches such as high cost, low throughput, technical difficulty, and strict infrastructure requirements. An inexpensive and compact Centrifuge Force Microscope (CFM) adapted to a commercial centrifuge enables use by nonspecialists, and integration with DNA nanoswitches facilitates both reliable measurements and repeated molecular interrogation. Here, we provide detailed protocols for constructing the CFM, creating DNA nanoswitch samples, and carrying out single-molecule force measurements.

  4. Time-to-pregnancy and pregnancy outcomes in a South African population

    PubMed Central

    2010-01-01

    Background Time-to-pregnancy (TTP) has never been studied in an African setting and there are no data on the rates of adverse pregnancy outcomes in South Africa. The study objectives were to measure TTP and the rates of adverse pregnancy outcomes in South Africa, and to determine the reliability of the questionnaire tool. Methods The study was cross-sectional and applied systematic stratified sampling to obtain a representative sample of reproductive age women for a South African population. Data on socio-demographic, work, health and reproductive variables were collected on 1121 women using a standardized questionnaire. A small number (n = 73) of randomly selected questionnaires was repeated to determine reliability of the questionnaire. Data was described using simple summary statistics while Kappa and intra-class correlation statistics were calculated for reliability. Results Of the 1121 women, 47 (4.2%) had never been pregnant. Mean gravidity was 2.3 while mean parity was 2.0 There were a total of 2467 pregnancies; most (87%) resulted in live births, 9.5% in spontaneous abortion and 2.2% in still births. The proportion of planned pregnancies was 39% and the median TTP was 6 months. The reliability of the questionnaire for TTP data was good; 63% for all participants and 97% when censored at 14 months. Overall reliability of reporting adverse pregnancy outcomes was very high, ranging from 90 - 98% for most outcomes. Conclusion This is the first comprehensive population-based reproductive health study in South Africa, to describe the biologic fertility of the population, and provides rates for planned pregnancies and adverse pregnancy outcomes. The reliability of the study questionnaire was substantial, with most outcomes within 70 - 100% reliability index. The study provides important public information for health practitioners and researchers in reproductive health. It also highlights the need for public health intervention programmes and epidemiological research on biologic fertility and adverse pregnancy outcomes in the population. PMID:20858279

  5. Predictors of validity and reliability of a physical activity record in adolescents

    PubMed Central

    2013-01-01

    Background Poor to moderate validity of self-reported physical activity instruments is commonly observed in young people in low- and middle-income countries. However, the reasons for such low validity have not been examined in detail. We tested the validity of a self-administered daily physical activity record in adolescents and assessed if personal characteristics or the convenience level of reporting physical activity modified the validity estimates. Methods The study comprised a total of 302 adolescents from an urban and rural area in Ecuador. Validity was evaluated by comparing the record with accelerometer recordings for seven consecutive days. Test-retest reliability was examined by comparing registrations from two records administered three weeks apart. Time spent on sedentary (SED), low (LPA), moderate (MPA) and vigorous (VPA) intensity physical activity was estimated. Bland Altman plots were used to evaluate measurement agreement. We assessed if age, sex, urban or rural setting, anthropometry and convenience of completing the record explained differences in validity estimates using a linear mixed model. Results Although the record provided higher estimates for SED and VPA and lower estimates for LPA and MPA compared to the accelerometer, it showed an overall fair measurement agreement for validity. There was modest reliability for assessing physical activity in each intensity level. Validity was associated with adolescents’ personal characteristics: sex (SED: P = 0.007; LPA: P = 0.001; VPA: P = 0.009) and setting (LPA: P = 0.000; MPA: P = 0.047). Reliability was associated with the convenience of completing the physical activity record for LPA (low convenience: P = 0.014; high convenience: P = 0.045). Conclusions The physical activity record provided acceptable estimates for reliability and validity on a group level. Sex and setting were associated with validity estimates, whereas convenience to fill out the record was associated with better reliability estimates for LPA. This tendency of improved reliability estimates for adolescents reporting higher convenience merits further consideration. PMID:24289296

  6. A Most Probable Point-Based Method for Reliability Analysis, Sensitivity Analysis and Design Optimization

    NASA Technical Reports Server (NTRS)

    Hou, Gene J.-W; Newman, Perry A. (Technical Monitor)

    2004-01-01

    A major step in a most probable point (MPP)-based method for reliability analysis is to determine the MPP. This is usually accomplished by using an optimization search algorithm. The minimum distance associated with the MPP provides a measurement of safety probability, which can be obtained by approximate probability integration methods such as FORM or SORM. The reliability sensitivity equations are derived first in this paper, based on the derivatives of the optimal solution. Examples are provided later to demonstrate the use of these derivatives for better reliability analysis and reliability-based design optimization (RBDO).

  7. Effective Hepatocyte Transplantation Using Rat Hepatocytes with Low Asialoglycoprotein Receptor Expression

    PubMed Central

    Ise, Hirohiko; Nikaido, Toshio; Negishi, Naoki; Sugihara, Nobuhiro; Suzuki, Fumitaka; Akaike, Toshihiro; Ikeda, Uichi

    2004-01-01

    Development of a reliable method of isolating highly proliferative potential hepatocytes provides information crucial to progress in the field of hepatocyte transplantation. The aim of this study was to develop reliable hepatocyte transplantation using highly proliferative, eg, progenitor-like hepatocytes, based on asialoglycoprotein receptor (ASGPR) expression levels for hepatocyte transplantation. We have previously reported that mouse hepatocytes with low ASGPR expression levels have highly proliferative potential and can be used as progenitor-like hepatocytes. We therefore fractionated F344 male rat hepatocytes expressing low and high levels of ASGPR and determined the liver repopulation capacity of hepatocytes according to low and high ASGPR expression in the liver. Next, 2 × 105 cells of each type were transplanted into female liver regenerative model dipeptidyl peptidase-deficient rats, and we estimated the rate of liver repopulation by the transplanted hepatocytes in the host liver, as determined by recognition of the Sry gene on the Y-chromosome. At 60 days after hepatocyte transplantation, the transplanted hepatocytes occupied ∼76% of the total hepatocyte mass in the case of the transplantation of hepatocytes with low ASGPR expression, but accounted for ∼12% and 17% of the mass in the case of the transplantation of hepatocytes with high ASGPR expression and unfractionated hepatocytes, respectively. In conclusion, these findings suggest that hepatocytes with low ASGPR expression can result in normal liver function and a high repopulation capacity in vivo. These results provide insight into development of a strategy for effective liver repopulation using transplanted hepatocytes. PMID:15277224

  8. Effective hepatocyte transplantation using rat hepatocytes with low asialoglycoprotein receptor expression.

    PubMed

    Ise, Hirohiko; Nikaido, Toshio; Negishi, Naoki; Sugihara, Nobuhiro; Suzuki, Fumitaka; Akaike, Toshihiro; Ikeda, Uichi

    2004-08-01

    Development of a reliable method of isolating highly proliferative potential hepatocytes provides information crucial to progress in the field of hepatocyte transplantation. The aim of this study was to develop reliable hepatocyte transplantation using highly proliferative, eg, progenitor-like hepatocytes, based on asialoglycoprotein receptor (ASGPR) expression levels for hepatocyte transplantation. We have previously reported that mouse hepatocytes with low ASGPR expression levels have highly proliferative potential and can be used as progenitor-like hepatocytes. We therefore fractionated F344 male rat hepatocytes expressing low and high levels of ASGPR and determined the liver repopulation capacity of hepatocytes according to low and high ASGPR expression in the liver. Next, 2 x 10(5) cells of each type were transplanted into female liver regenerative model dipeptidyl peptidase-deficient rats, and we estimated the rate of liver repopulation by the transplanted hepatocytes in the host liver, as determined by recognition of the Sry gene on the Y-chromosome. At 60 days after hepatocyte transplantation, the transplanted hepatocytes occupied approximately 76% of the total hepatocyte mass in the case of the transplantation of hepatocytes with low ASGPR expression, but accounted for approximately 12% and 17% of the mass in the case of the transplantation of hepatocytes with high ASGPR expression and unfractionated hepatocytes, respectively. In conclusion, these findings suggest that hepatocytes with low ASGPR expression can result in normal liver function and a high repopulation capacity in vivo. These results provide insight into development of a strategy for effective liver repopulation using transplanted hepatocytes.

  9. Design for a Crane Metallic Structure Based on Imperialist Competitive Algorithm and Inverse Reliability Strategy

    NASA Astrophysics Data System (ADS)

    Fan, Xiao-Ning; Zhi, Bo

    2017-07-01

    Uncertainties in parameters such as materials, loading, and geometry are inevitable in designing metallic structures for cranes. When considering these uncertainty factors, reliability-based design optimization (RBDO) offers a more reasonable design approach. However, existing RBDO methods for crane metallic structures are prone to low convergence speed and high computational cost. A unilevel RBDO method, combining a discrete imperialist competitive algorithm with an inverse reliability strategy based on the performance measure approach, is developed. Application of the imperialist competitive algorithm at the optimization level significantly improves the convergence speed of this RBDO method. At the reliability analysis level, the inverse reliability strategy is used to determine the feasibility of each probabilistic constraint at each design point by calculating its α-percentile performance, thereby avoiding convergence failure, calculation error, and disproportionate computational effort encountered using conventional moment and simulation methods. Application of the RBDO method to an actual crane structure shows that the developed RBDO realizes a design with the best tradeoff between economy and safety together with about one-third of the convergence speed and the computational cost of the existing method. This paper provides a scientific and effective design approach for the design of metallic structures of cranes.

  10. Validation and cross cultural adaptation of the Italian version of the Harris Hip Score.

    PubMed

    Dettoni, Federico; Pellegrino, Pietro; La Russa, Massimo R; Bonasia, Davide E; Blonna, Davide; Bruzzone, Matteo; Castoldi, Filippo; Rossi, Roberto

    2015-01-01

    The Harris Hip Score (HHS) is one of the most widely used health related quality of life (HRQOL) measures for the assessment of hip pathology: in spite of this, a validation study, and an official Italian version have not been provided yet. The aim of this study was to create an Italian valid and reliable version of the HHS. The score was translated and modified in Italian; then 103 patients with different hip pathologies were evaluated using this HHS version and also with the WOMAC and the SF-12 questionnaires. Content, construct and criterion validities were tested, such as interobserver reliability, test-retest reliability and internal consistency. Cross-cultural adaptation was easy, and only minor adaptation was required in the translation process. Construct and criterion validity of the HHS Italian Version were confirmed by satisfactory values of Spearman's Rho for correlation between specific domains of HHS and Womac and SF12 scores. Interobserver and test-retest reliabilities obtained values of 0.996 and 0.975 respectively; Cronbach's alpha for internal consistency was 0.816. Statistical and clinical analysis showed that HHS is highly valid and reliable in this new Italian version.

  11. Brief Assessment of Motor Function: Content Validity and Reliability of the Upper Extremity Gross Motor Scale

    PubMed Central

    Cintas, Holly Lea; Parks, Rebecca; Don, Sarah; Gerber, Lynn

    2011-01-01

    Content validity and reliability of the Brief Assessment of Motor Function (BAMF) Upper Extremity Gross Motor Scale (UEGMS) were evaluated in this prospective, descriptive study. The UEGMS is one of five ordinal scales designed for quick documentation of gross, fine and oral motor skill levels. Designed to be independent of age and diagnosis, it is intended for use for infants through young adults. An expert panel of 17 physical therapists and 13 occupational therapists refined the content by responding to a standard questionnaire comprised of questions which asked whether each item should be included, is clearly worded, should be reordered higher or lower, is functionally relevant, and is easily discriminated. Ratings of content validity exceeded the criterion except for two items which may represent different perspectives of physical and occupational therapists. The UEGMS was modified using the quantitative and qualitative feedback from the questionnaires. For reliability, five raters scored videotaped motor performances of ten children. Coefficients for inter-rater (0.94) and intra-rater (0.95) reliability were high. The results provide evidence of content validity and reliability of the UEGMS for assessment of upper extremity gross motor skill. PMID:21599568

  12. Development of Constellation's Launch Control System

    NASA Technical Reports Server (NTRS)

    Lougheed, Kirk D.; Peaden, Cary J.

    2010-01-01

    The paper focuses on the National Aeronautics and Space Administration (NASA) Constellation Program's Launch Control System (LCS) development effort at Kennedy Space Center (KSC). It provides a brief history of some preceding efforts to provide launch control and ground processing systems for other NASA programs, and some lessons learned from those experiences. It then provides high level descriptions of the LCS mission, objectives, organization, architecture, and progress. It discusses some of our development tenets, including our use of standards based design and use of off-the-shelf products whenever possible, incremental development cycles, and highly reliable, available, and supportable enterprise class system servers. It concludes with some new lessons learned and our plans for the future.

  13. 18 CFR 39.3 - Electric Reliability Organization certification.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... operators of the Bulk-Power System, and other interested parties for improvement of the Electric Reliability... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Electric Reliability..., Reliability Standards that provide for an adequate level of reliability of the Bulk-Power System, and (2) Has...

  14. 77 FR 39895 - New Analytic Methods and Sampling Procedures for the United States National Residue Program for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-06

    ... Analytic Methods and Sampling Procedures for the United States National Residue Program for Meat, Poultry... implementing several multi-residue methods for analyzing samples of meat, poultry, and egg products for animal.... These modern, high-efficiency methods will conserve resources and provide useful and reliable results...

  15. High reliability low jitter pulse generator

    DOEpatents

    Savage, Mark E.; Stoltzfus, Brian S.

    2013-01-01

    A method and concomitant apparatus for generating pulses comprising providing a laser light source, disposing a voltage electrode between ground electrodes, generating laser sparks using the laser light source via laser spark gaps between the voltage electrode and the ground electrodes, and outputting pulses via one or more insulated ground connectors connected to the voltage electrode.

  16. Development of a High Throughput Assay for Rapid and Accurate 10-Plex Detection of Citrus Pathogens

    USDA-ARS?s Scientific Manuscript database

    The need to reliably detect and identify multiple plant pathogens simultaneously, especially in woody perennial hosts, has led to development of new molecular diagnostic approaches. In this study, a Luminex-based system was developed that provided a robust and sensitive test for simultaneous detect...

  17. Optimization of SIS mixer elements

    NASA Technical Reports Server (NTRS)

    Mattauch, Robert J.

    1985-01-01

    Superconductor-Insulator-Superconductor (SIS) quantum mixers provide an approach to millimeter wave mixing - potentially offering conversion gain, a low local oscillator power demand, and potential mixer noise temperatures near the quantum limit. The development of a reliable fabrication technology for producing such high quality SIS devices for mixer applications in radio astronomy is the focus of the work.

  18. Identifying Technical Vocabulary

    ERIC Educational Resources Information Center

    Chung, Teresa Mihwa; Nation, Paul

    2004-01-01

    This study compared four different approaches to identifying technical words in an anatomy text. The first approach used a four step rating scale, and was used as the comparison for evaluating the other three approaches. It had a high degree of reliability. The least successful approach was that using clues provided by the writer such as labels in…

  19. Comparisons of seed longevity under simulated aging and genebank storage conditions using brassicaceae seeds

    USDA-ARS?s Scientific Manuscript database

    Seeds survive for years under dry conditions but then viability crashes without warning. Efforts to provide high quality seeds to customers, breed longer-living seeds, or to investigate the underlying causes of deterioration during storage prompt the need for a reliable measure of the longevity phe...

  20. Advances in the Two Source Energy Balance (TSEB) model using very high resolution remote sensing data in vineyards

    USDA-ARS?s Scientific Manuscript database

    The thermal-based Two Source Energy Balance (TSEB) model partitions the water and energy fluxes from vegetation and soil components providing thus the ability for estimating soil evaporation (E) and canopy transpiration (T) separately. However, it is crucial for ET partitioning to retrieve reliable ...

  1. Popular or Unpopular? Therapists' Use of Structured Interviews and Their Estimation of Patient Acceptance

    ERIC Educational Resources Information Center

    Bruchmuller, Katrin; Margraf, Jurgen; Suppiger, Andrea; Schneider, Silvia

    2011-01-01

    An accurate diagnosis is an important precondition for effective psychotherapeutic treatment. The use of structured interviews provides the gold standard for reliable diagnosis. Suppiger et al. (2009) showed that structured interviews have a high acceptance among patients. On a scale from 0 ("not at all satisfied") to 100 ("totally…

  2. Accelerated life testing effects on CMOS microcircuit characteristics

    NASA Technical Reports Server (NTRS)

    1979-01-01

    Modifications and additions to the present process of making CMOS microcircuits which are designed to provide protective layers on the chip to guard against moisture and contaminants were investigated. High and low temperature Si3N4 protective layers were tested on the CMOS microcircuits and no conclusive improvements in device reliability characteristics were evidenced.

  3. A Cross-Layer Optimized Opportunistic Routing Scheme for Loss-and-Delay Sensitive WSNs

    PubMed Central

    Xu, Xin; Yuan, Minjiao; Liu, Xiao; Cai, Zhiping; Wang, Tian

    2018-01-01

    In wireless sensor networks (WSNs), communication links are typically error-prone and unreliable, so providing reliable and timely data routing for loss- and delay-sensitive applications in WSNs it is a challenge issue. Additionally, with specific thresholds in practical applications, the loss and delay sensitivity implies requirements for high reliability and low delay. Opportunistic Routing (OR) has been well studied in WSNs to improve reliability for error-prone and unreliable wireless communication links where the transmission power is assumed to be identical in the whole network. In this paper, a Cross-layer Optimized Opportunistic Routing (COOR) scheme is proposed to improve the communication link reliability and reduce delay for loss-and-delay sensitive WSNs. The main contribution of the COOR scheme is making full use of the remaining energy in networks to increase the transmission power of most nodes, which will provide a higher communication reliability or further transmission distance. Two optimization strategies referred to as COOR(R) and COOR(P) of the COOR scheme are proposed to improve network performance. In the case of increasing the transmission power, the COOR(R) strategy chooses a node that has a higher communication reliability with same distance in comparison to the traditional opportunistic routing when selecting the next hop candidate node. Since the reliability of data transmission is improved, the delay of the data reaching the sink is reduced by shortening the time of communication between candidate nodes. On the other hand, the COOR(P) strategy prefers a node that has the same communication reliability with longer distance. As a result, network performance can be improved for the following reasons: (a) the delay is reduced as fewer hops are needed while the packet reaches the sink in longer transmission distance circumstances; (b) the reliability can be improved since it is the product of the reliability of every hop of the routing path, and the count is reduced while the reliability of each hop is the same as the traditional method. After analyzing the energy consumption of the network in detail, the value of optimized transmission power in different areas is given. On the basis of a large number of experimental and theoretical analyses, the results show that the COOR scheme will increase communication reliability by 36.62–87.77%, decrease delay by 21.09–52.48%, and balance the energy consumption of 86.97% of the nodes in the WSNs. PMID:29751589

  4. A Cross-Layer Optimized Opportunistic Routing Scheme for Loss-and-Delay Sensitive WSNs.

    PubMed

    Xu, Xin; Yuan, Minjiao; Liu, Xiao; Liu, Anfeng; Xiong, Neal N; Cai, Zhiping; Wang, Tian

    2018-05-03

    In wireless sensor networks (WSNs), communication links are typically error-prone and unreliable, so providing reliable and timely data routing for loss- and delay-sensitive applications in WSNs it is a challenge issue. Additionally, with specific thresholds in practical applications, the loss and delay sensitivity implies requirements for high reliability and low delay. Opportunistic Routing (OR) has been well studied in WSNs to improve reliability for error-prone and unreliable wireless communication links where the transmission power is assumed to be identical in the whole network. In this paper, a Cross-layer Optimized Opportunistic Routing (COOR) scheme is proposed to improve the communication link reliability and reduce delay for loss-and-delay sensitive WSNs. The main contribution of the COOR scheme is making full use of the remaining energy in networks to increase the transmission power of most nodes, which will provide a higher communication reliability or further transmission distance. Two optimization strategies referred to as COOR(R) and COOR(P) of the COOR scheme are proposed to improve network performance. In the case of increasing the transmission power, the COOR(R) strategy chooses a node that has a higher communication reliability with same distance in comparison to the traditional opportunistic routing when selecting the next hop candidate node. Since the reliability of data transmission is improved, the delay of the data reaching the sink is reduced by shortening the time of communication between candidate nodes. On the other hand, the COOR(P) strategy prefers a node that has the same communication reliability with longer distance. As a result, network performance can be improved for the following reasons: (a) the delay is reduced as fewer hops are needed while the packet reaches the sink in longer transmission distance circumstances; (b) the reliability can be improved since it is the product of the reliability of every hop of the routing path, and the count is reduced while the reliability of each hop is the same as the traditional method. After analyzing the energy consumption of the network in detail, the value of optimized transmission power in different areas is given. On the basis of a large number of experimental and theoretical analyses, the results show that the COOR scheme will increase communication reliability by 36.62⁻87.77%, decrease delay by 21.09⁻52.48%, and balance the energy consumption of 86.97% of the nodes in the WSNs.

  5. Storage system software solutions for high-end user needs

    NASA Technical Reports Server (NTRS)

    Hogan, Carole B.

    1992-01-01

    Today's high-end storage user is one that requires rapid access to a reliable terabyte-capacity storage system running in a distributed environment. This paper discusses conventional storage system software and concludes that this software, designed for other purposes, cannot meet high-end storage requirements. The paper also reviews the philosophy and design of evolving storage system software. It concludes that this new software, designed with high-end requirements in mind, provides the potential for solving not only the storage needs of today but those of the foreseeable future as well.

  6. The implementation and use of Ada on distributed systems with high reliability requirements

    NASA Technical Reports Server (NTRS)

    Knight, J. C.

    1984-01-01

    The use and implementation of Ada in distributed environments in which reliability is the primary concern is investigated. Emphasis is placed on the possibility that a distributed system may be programmed entirely in ADA so that the individual tasks of the system are unconcerned with which processors they are executing on, and that failures may occur in the software or underlying hardware. The primary activities are: (1) Continued development and testing of our fault-tolerant Ada testbed; (2) consideration of desirable language changes to allow Ada to provide useful semantics for failure; (3) analysis of the inadequacies of existing software fault tolerance strategies.

  7. Testing the Wildlink activity-detection system on wolves and white-tailed deer

    USGS Publications Warehouse

    Kunkel, K.E.; Chapman, R.C.; Mech, L.D.; Gese, E.M.

    1991-01-01

    We tested the reliability and predictive capabilities of the activity meter in the new Wildlink Data Acquisition and Recapture System by comparing activity counts with concurrent observations of captive wolf (Canis lupus) and free-ranging white-tailed deer (Odocoileus virginianus) activity. The Wildlink system stores activity data in a computer within a radio collar with which a biologist can communicate. Three levels of activity could be detected. The Wildlink system provided greater activity discrimination and was more reliable, adaptable, and efficient and was easier to use than conventional telemetry activity systems. The Wildlink system could be highly useful for determining wildlife energy budgets.

  8. Exploiting replication in distributed systems

    NASA Technical Reports Server (NTRS)

    Birman, Kenneth P.; Joseph, T. A.

    1989-01-01

    Techniques are examined for replicating data and execution in directly distributed systems: systems in which multiple processes interact directly with one another while continuously respecting constraints on their joint behavior. Directly distributed systems are often required to solve difficult problems, ranging from management of replicated data to dynamic reconfiguration in response to failures. It is shown that these problems reduce to more primitive, order-based consistency problems, which can be solved using primitives such as the reliable broadcast protocols. Moreover, given a system that implements reliable broadcast primitives, a flexible set of high-level tools can be provided for building a wide variety of directly distributed application programs.

  9. Mechanically and optically reliable folding structure with a hyperelastic material for seamless foldable displays

    NASA Astrophysics Data System (ADS)

    Kwon, Hyuk-Jun; Shim, HongShik; Kim, Sunkook; Choi, Woong; Chun, Youngtea; Kee, InSeo; Lee, SangYoon

    2011-04-01

    We report a mechanically and optically robust folding structure to realize a foldable active matrix organic-light-emitting-diode (AMOLED) display without a visible crease at the junction. A nonlinear stress analysis, based on a finite element method, provided an optimized design. The folding-unfolding test on the structure exhibited negligible deterioration of the relative brightness at the junction of the individual panels up to 105 cycles at a folding radius of 1 mm, indicating highly reliable mechanical and optical tolerances. These results demonstrate the feasibility of seamless foldable AMOLED displays, with potentially important technical implications on fabricating large size flexible displays.

  10. Energy recovery with turboexpander processes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holm, J.

    1985-07-01

    Although the primary function of turboexpanders has been to provide efficient, low-temperature refrigeration, the energy thus extracted has also been an important additional feature. Today, turboexpanders are proven reliable and used widely in the following applications discussed in this article: industrial gases; natural gas (NG) processing; production of liquefied natural gas (LNG); flashing hydrocarbon liquids; NG pressure letdown energy recovery; oilfield cogeneration; and recovery of energy from waste heat. Turboexpander applications for energy conservation resulted because available turboexpanders have the required high-performance capabilities and reliability. At the same time, the development of these energy conservation practices and processes helped furthermore » improve turboexpanders.« less

  11. Japanese version of the Dermatology Life Quality Index: validity and reliability in patients with acne.

    PubMed

    Takahashi, Natsuko; Suzukamo, Yoshimi; Nakamura, Motonobu; Miyachi, Yoshiki; Green, Joseph; Ohya, Yukihiro; Finlay, Andrew Y; Fukuhara, Shunichi

    2006-08-03

    Patient-reported quality of life is strongly affected by some dermatologic conditions. We developed a Japanese version of the Dermatology Life Quality Index (DLQI-J) and used psychometric methods to examine its validity and reliability. The Japanese version of the DLQI was created from the original (English) version, using a standard method. The DLQI-J was then completed by 197 people, to examine its validity and reliability. Some participants completed the DLQI-J a second time, 3 days later, to examine the reproducibility of their responses. In addition to the DLQI-J, the participants completed parts of the SF-36 and gave data on their demographic and clinical characteristics. Their physicians provided information on the location and clinical severity of the skin disease. The participants reported no difficulties in answering the DLQI-J items. Their mean age was 24.8 years, 77.2% were female, and 78.7% had acne vulgaris. The mean score of DLQI was 3.99(SD: 3.99). The responses were found to be reproducible and stable. Results of principal-component and factor analysis suggested that this scale measured one construct. The correlations of DLQI-J scores with sex or age were very poor, but those with SF-36 scores and with clinical severity were high. The DLQI-J provides valid and reliable data despite having only a small number of items.

  12. Segmental Musculoskeletal Examinations using Dual-Energy X-Ray Absorptiometry (DXA): Positioning and Analysis Considerations

    PubMed Central

    Hart, Nicolas H.; Nimphius, Sophia; Spiteri, Tania; Cochrane, Jodie L.; Newton, Robert U.

    2015-01-01

    Musculoskeletal examinations provide informative and valuable quantitative insight into muscle and bone health. DXA is one mainstream tool used to accurately and reliably determine body composition components and bone mass characteristics in-vivo. Presently, whole body scan models separate the body into axial and appendicular regions, however there is a need for localised appendicular segmentation models to further examine regions of interest within the upper and lower extremities. Similarly, inconsistencies pertaining to patient positioning exist in the literature which influence measurement precision and analysis outcomes highlighting a need for standardised procedure. This paper provides standardised and reproducible: 1) positioning and analysis procedures using DXA and 2) reliable segmental examinations through descriptive appendicular boundaries. Whole-body scans were performed on forty-six (n = 46) football athletes (age: 22.9 ± 4.3 yrs; height: 1.85 ± 0.07 cm; weight: 87.4 ± 10.3 kg; body fat: 11.4 ± 4.5 %) using DXA. All segments across all scans were analysed three times by the main investigator on three separate days, and by three independent investigators a week following the original analysis. To examine intra-rater and inter-rater, between day and researcher reliability, coefficients of variation (CV) and intraclass correlation coefficients (ICC) were determined. Positioning and segmental analysis procedures presented in this study produced very high, nearly perfect intra-tester (CV ≤ 2.0%; ICC ≥ 0.988) and inter-tester (CV ≤ 2.4%; ICC ≥ 0.980) reliability, demonstrating excellent reproducibility within and between practitioners. Standardised examinations of axial and appendicular segments are necessary. Future studies aiming to quantify and report segmental analyses of the upper- and lower-body musculoskeletal properties using whole-body DXA scans are encouraged to use the patient positioning and image analysis procedures outlined in this paper. Key points Musculoskeletal examinations using DXA technology require highly standardised and reproducible patient positioning and image analysis procedures to accurately measure and monitor axial, appendicular and segmental regions of interest. Internal rotation and fixation of the lower-limbs is strongly recommended during whole-body DXA scans to prevent undesired movement, improve frontal mass accessibility and enhance ankle joint visibility during scan performance and analysis. Appendicular segmental analyses using whole-body DXA scans are highly reliable for all regional upper-body and lower-body segmentations, with hard-tissue (CV ≤ 1.5%; R ≥ 0.990) achieving greater reliability and lower error than soft-tissue (CV ≤ 2.4%; R ≥ 0.980) masses when using our appendicular segmental boundaries. PMID:26336349

  13. Making literature reviews more reliable through application of lessons from systematic reviews.

    PubMed

    Haddaway, N R; Woodcock, P; Macura, B; Collins, A

    2015-12-01

    Review articles can provide valuable summaries of the ever-increasing volume of primary research in conservation biology. Where findings may influence important resource-allocation decisions in policy or practice, there is a need for a high degree of reliability when reviewing evidence. However, traditional literature reviews are susceptible to a number of biases during the identification, selection, and synthesis of included studies (e.g., publication bias, selection bias, and vote counting). Systematic reviews, pioneered in medicine and translated into conservation in 2006, address these issues through a strict methodology that aims to maximize transparency, objectivity, and repeatability. Systematic reviews will always be the gold standard for reliable synthesis of evidence. However, traditional literature reviews remain popular and will continue to be valuable where systematic reviews are not feasible. Where traditional reviews are used, lessons can be taken from systematic reviews and applied to traditional reviews in order to increase their reliability. Certain key aspects of systematic review methods that can be used in a context-specific manner in traditional reviews include focusing on mitigating bias; increasing transparency, consistency, and objectivity, and critically appraising the evidence and avoiding vote counting. In situations where conducting a full systematic review is not feasible, the proposed approach to reviewing evidence in a more systematic way can substantially improve the reliability of review findings, providing a time- and resource-efficient means of maximizing the value of traditional reviews. These methods are aimed particularly at those conducting literature reviews where systematic review is not feasible, for example, for graduate students, single reviewers, or small organizations. © 2015 Society for Conservation Biology.

  14. An Adaptation of the Original Fresno Test to Measure Evidence-Based Practice Competence in Pediatric Bedside Nurses.

    PubMed

    Laibhen-Parkes, Natasha; Kimble, Laura P; Melnyk, Bernadette Mazurek; Sudia, Tanya; Codone, Susan

    2018-06-01

    Instruments used to assess evidence-based practice (EBP) competence in nurses have been subjective, unreliable, or invalid. The Fresno test was identified as the only instrument to measure all the steps of EBP with supportive reliability and validity data. However, the items and psychometric properties of the original Fresno test are only relevant to measure EBP with medical residents. Therefore, the purpose of this paper is to describe the development of the adapted Fresno test for pediatric nurses, and provide preliminary validity and reliability data for its use with Bachelor of Science in Nursing-prepared pediatric bedside nurses. General adaptations were made to the original instrument's case studies, item content, wording, and format to meet the needs of a pediatric nursing sample. The scoring rubric was also modified to complement changes made to the instrument. Content and face validity, and intrarater reliability of the adapted Fresno test were assessed during a mixed-methods pilot study conducted from October to December 2013 with 29 Bachelor of Science in Nursing-prepared pediatric nurses. Validity data provided evidence for good content and face validity. Intrarater reliability estimates were high. The adapted Fresno test presented here appears to be a valid and reliable assessment of EBP competence in Bachelor of Science in Nursing-prepared pediatric nurses. However, further testing of this instrument is warranted using a larger sample of pediatric nurses in diverse settings. This instrument can be a starting point for evaluating the impact of EBP competence on patient outcomes. © 2018 Sigma Theta Tau International.

  15. Validation of the INCEPT: A Multisource Feedback Tool for Capturing Different Perspectives on Physicians' Professional Performance.

    PubMed

    van der Meulen, Mirja W; Boerebach, Benjamin C M; Smirnova, Alina; Heeneman, Sylvia; Oude Egbrink, Mirjam G A; van der Vleuten, Cees P M; Arah, Onyebuchi A; Lombarts, Kiki M J M H

    2017-01-01

    Multisource feedback (MSF) instruments are used to and must feasibly provide reliable and valid data on physicians' performance from multiple perspectives. The "INviting Co-workers to Evaluate Physicians Tool" (INCEPT) is a multisource feedback instrument used to evaluate physicians' professional performance as perceived by peers, residents, and coworkers. In this study, we report on the validity, reliability, and feasibility of the INCEPT. The performance of 218 physicians was assessed by 597 peers, 344 residents, and 822 coworkers. Using explorative and confirmatory factor analyses, multilevel regression analyses between narrative and numerical feedback, item-total correlations, interscale correlations, Cronbach's α and generalizability analyses, the psychometric qualities, and feasibility of the INCEPT were investigated. For all respondent groups, three factors were identified, although constructed slightly different: "professional attitude," "patient-centeredness," and "organization and (self)-management." Internal consistency was high for all constructs (Cronbach's α ≥ 0.84 and item-total correlations ≥ 0.52). Confirmatory factor analyses indicated acceptable to good fit. Further validity evidence was given by the associations between narrative and numerical feedback. For reliable total INCEPT scores, three peer, two resident and three coworker evaluations were needed; for subscale scores, evaluations of three peers, three residents and three to four coworkers were sufficient. The INCEPT instrument provides physicians performance feedback in a valid and reliable way. The number of evaluations to establish reliable scores is achievable in a regular clinical department. When interpreting feedback, physicians should consider that respondent groups' perceptions differ as indicated by the different item clustering per performance factor.

  16. Managing Complex IT Security Processes with Value Based Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abercrombie, Robert K; Sheldon, Frederick T; Mili, Ali

    2009-01-01

    Current trends indicate that IT security measures will need to greatly expand to counter the ever increasingly sophisticated, well-funded and/or economically motivated threat space. Traditional risk management approaches provide an effective method for guiding courses of action for assessment, and mitigation investments. However, such approaches no matter how popular demand very detailed knowledge about the IT security domain and the enterprise/cyber architectural context. Typically, the critical nature and/or high stakes require careful consideration and adaptation of a balanced approach that provides reliable and consistent methods for rating vulnerabilities. As reported in earlier works, the Cyberspace Security Econometrics System provides amore » comprehensive measure of reliability, security and safety of a system that accounts for the criticality of each requirement as a function of one or more stakeholders interests in that requirement. This paper advocates a dependability measure that acknowledges the aggregate structure of complex system specifications, and accounts for variations by stakeholder, by specification components, and by verification and validation impact.« less

  17. Factor Structure, Reliability and Measurement Invariance of the Alberta Context Tool and the Conceptual Research Utilization Scale, for German Residential Long Term Care

    PubMed Central

    Hoben, Matthias; Estabrooks, Carole A.; Squires, Janet E.; Behrens, Johann

    2016-01-01

    We translated the Canadian residential long term care versions of the Alberta Context Tool (ACT) and the Conceptual Research Utilization (CRU) Scale into German, to study the association between organizational context factors and research utilization in German nursing homes. The rigorous translation process was based on best practice guidelines for tool translation, and we previously published methods and results of this process in two papers. Both instruments are self-report questionnaires used with care providers working in nursing homes. The aim of this study was to assess the factor structure, reliability, and measurement invariance (MI) between care provider groups responding to these instruments. In a stratified random sample of 38 nursing homes in one German region (Metropolregion Rhein-Neckar), we collected questionnaires from 273 care aides, 196 regulated nurses, 152 allied health providers, 6 quality improvement specialists, 129 clinical leaders, and 65 nursing students. The factor structure was assessed using confirmatory factor models. The first model included all 10 ACT concepts. We also decided a priori to run two separate models for the scale-based and the count-based ACT concepts as suggested by the instrument developers. The fourth model included the five CRU Scale items. Reliability scores were calculated based on the parameters of the best-fitting factor models. Multiple-group confirmatory factor models were used to assess MI between provider groups. Rather than the hypothesized ten-factor structure of the ACT, confirmatory factor models suggested 13 factors. The one-factor solution of the CRU Scale was confirmed. The reliability was acceptable (>0.7 in the entire sample and in all provider groups) for 10 of 13 ACT concepts, and high (0.90–0.96) for the CRU Scale. We could demonstrate partial strong MI for both ACT models and partial strict MI for the CRU Scale. Our results suggest that the scores of the German ACT and the CRU Scale for nursing homes are acceptably reliable and valid. However, as the ACT lacked strict MI, observed variables (or scale scores based on them) cannot be compared between provider groups. Rather, group comparisons should be based on latent variable models, which consider the different residual variances of each group. PMID:27656156

  18. Transit Reliability Information Program : PATCO-WMATA Propulsion System Reliability/Productivity Analysis

    DOT National Transportation Integrated Search

    1984-10-01

    The Transit Reliability Information Program (TRIP) is a government-initiated program to assist the transit industry in satisfying its need for transit reliability information. TRIP provides this assistance through the operation of a national data ban...

  19. Reliability Demonstration Approach for Advanced Stirling Radioisotope Generator

    NASA Technical Reports Server (NTRS)

    Ha, CHuong; Zampino, Edward; Penswick, Barry; Spronz, Michael

    2010-01-01

    Developed for future space missions as a high-efficiency power system, the Advanced Stirling Radioisotope Generator (ASRG) has a design life requirement of 14 yr in space following a potential storage of 3 yr after fueling. In general, the demonstration of long-life dynamic systems remains difficult in part due to the perception that the wearout of moving parts cannot be minimized, and associated failures are unpredictable. This paper shows a combination of systematic analytical methods, extensive experience gained from technology development, and well-planned tests can be used to ensure a high level reliability of ASRG. With this approach, all potential risks from each life phase of the system are evaluated and the mitigation adequately addressed. This paper also provides a summary of important test results obtained to date for ASRG and the planned effort for system-level extended operation.

  20. A reliability analysis of the revised competitiveness index.

    PubMed

    Harris, Paul B; Houston, John M

    2010-06-01

    This study examined the reliability of the Revised Competitiveness Index by investigating the test-retest reliability, interitem reliability, and factor structure of the measure based on a sample of 280 undergraduates (200 women, 80 men) ranging in age from 18 to 28 years (M = 20.1, SD = 2.1). The findings indicate that the Revised Competitiveness Index has high test-retest reliability, high inter-item reliability, and a stable factor structure. The results support the assertion that the Revised Competitiveness Index assesses competitiveness as a stable trait rather than a dynamic state.

  1. Accurate identification of motor unit discharge patterns from high-density surface EMG and validation with a novel signal-based performance metric

    NASA Astrophysics Data System (ADS)

    Holobar, A.; Minetto, M. A.; Farina, D.

    2014-02-01

    Objective. A signal-based metric for assessment of accuracy of motor unit (MU) identification from high-density surface electromyograms (EMG) is introduced. This metric, so-called pulse-to-noise-ratio (PNR), is computationally efficient, does not require any additional experimental costs and can be applied to every MU that is identified by the previously developed convolution kernel compensation technique. Approach. The analytical derivation of the newly introduced metric is provided, along with its extensive experimental validation on both synthetic and experimental surface EMG signals with signal-to-noise ratios ranging from 0 to 20 dB and muscle contraction forces from 5% to 70% of the maximum voluntary contraction. Main results. In all the experimental and simulated signals, the newly introduced metric correlated significantly with both sensitivity and false alarm rate in identification of MU discharges. Practically all the MUs with PNR > 30 dB exhibited sensitivity >90% and false alarm rates <2%. Therefore, a threshold of 30 dB in PNR can be used as a simple method for selecting only reliably decomposed units. Significance. The newly introduced metric is considered a robust and reliable indicator of accuracy of MU identification. The study also shows that high-density surface EMG can be reliably decomposed at contraction forces as high as 70% of the maximum.

  2. Reliable, Low-Cost, Low-Weight, Non-Hermetic Coating for MCM Applications

    NASA Technical Reports Server (NTRS)

    Jones, Eric W.; Licari, James J.

    2000-01-01

    Through an Air Force Research Laboratory sponsored STM program, reliable, low-cost, low-weight, non-hermetic coatings for multi-chip-module(MCK applications were developed. Using the combination of Sandia Laboratory ATC-01 test chips, AvanTeco's moisture sensor chips(MSC's), and silicon slices, we have shown that organic and organic/inorganic overcoatings are reliable and practical non-hermetic moisture and oxidation barriers. The use of the MSC and unpassivated ATC-01 test chips provided rapid test results and comparison of moisture barrier quality of the overcoatings. The organic coatings studied were Parylene and Cyclotene. The inorganic coatings were Al2O3 and SiO2. The choice of coating(s) is dependent on the environment that the device(s) will be exposed to. We have defined four(4) classes of environments: Class I(moderate temperature/moderate humidity). Class H(high temperature/moderate humidity). Class III(moderate temperature/high humidity). Class IV(high temperature/high humidity). By subjecting the components to adhesion, FTIR, temperature-humidity(TH), pressure cooker(PCT), and electrical tests, we have determined that it is possible to reduce failures 50-70% for organic/inorganic coated components compared to organic coated components. All materials and equipment used are readily available commercially or are standard in most semiconductor fabrication lines. It is estimated that production cost for the developed technology would range from $1-10/module, compared to $20-200 for hermetically sealed packages.

  3. Soldier Dimensions in Combat Models

    DTIC Science & Technology

    1990-05-07

    and performance. Questionnaires, SQTs, and ARTEPs were often used. Many scales had estimates of reliability but few had validity data. Most studies...pending its validation . Research plans were provided for applications in simulated combat and with simulation devices, for data previously gathered...regarding reliability and validity . Lack of information following an instrument indicates neither reliability nor validity information was provided by the

  4. Test-retest reliability and responsiveness of gaze stability and dynamic visual acuity in high school and college football players.

    PubMed

    Kaufman, Denise R; Puckett, Mallory J; Smith, Mitchell J; Wilson, Kyle S; Cheema, Rebecca; Landers, Merrill R

    2014-08-01

    The purpose of this study was to establish reliability and responsiveness of the dynamic visual acuity test (DVAT) at head speeds of 150-200 degrees per second (deg/s) and the gaze stabilization test (GST) in high school and college football players. Reliability design. Fifty high school and college football athletes completed the DVAT and GST in both the yaw (horizontal) and pitch (vertical) planes twice within two weeks. Test-retest reliability for the DVAT was good in yaw, Intraclass Correlation Coefficient (ICC) = 0.770, and moderate/good in pitch, ICC = 0.725. Minimal detectable change (MDC) was 0.16 logMAR for yaw and 0.21 logMAR for pitch. GST reliability was moderate in yaw, ICC = 0.634, and poor in pitch, ICC = 0.411. MDCs were 73.4 deg/s (yaw) and 81.2 deg/s (pitch). The DVAT is reliable at high head speeds in high school and college football athletes in both yaw and pitch. GST head speeds were higher than previously reported in the literature, but reliability of this tool for this population was poor to moderate. From a clinical perspective, DVAT may be reliably used in the assessment of high school and college football athletes; however, GST requires further evaluation. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Private sector, for-profit health providers in low and middle income countries: can they reach the poor at scale?

    PubMed

    Tung, Elizabeth; Bennett, Sara

    2014-06-24

    The bottom of the pyramid concept suggests that profit can be made in providing goods and services to poor people, when high volume is combined with low margins. To-date there has been very limited empirical evidence from the health sector concerning the scope and potential for such bottom of the pyramid models. This paper analyzes private for-profit (PFP) providers currently offering services to the poor on a large scale, and assesses the future prospects of bottom of the pyramid models in health. We searched published and grey literature and databases to identify PFP companies that provided more than 40,000 outpatient visits per year, or who covered 15% or more of a particular type of service in their country. For each included provider, we searched for additional information on location, target market, business model and performance, including quality of care. Only 10 large scale PFP providers were identified. The majority of these were in South Asia and most provided specialized services such as eye care. The characteristics of the business models of these firms were found to be similar to non-profit providers studied by other analysts (such as Bhattacharya 2010). They pursued social rather than traditional marketing, partnerships with government, low cost/high volume services and cross-subsidization between different market segments. There was a lack of reliable data concerning these providers. There is very limited evidence to support the notion that large scale bottom of the pyramid models in health offer good prospects for extending services to the poor in the future. In order to be successful PFP providers often require partnerships with government or support from social health insurance schemes. Nonetheless, more reliable and independent data on such schemes is needed.

  6. Private sector, for-profit health providers in low and middle income countries: can they reach the poor at scale?

    PubMed Central

    2014-01-01

    Background The bottom of the pyramid concept suggests that profit can be made in providing goods and services to poor people, when high volume is combined with low margins. To-date there has been very limited empirical evidence from the health sector concerning the scope and potential for such bottom of the pyramid models. This paper analyzes private for-profit (PFP) providers currently offering services to the poor on a large scale, and assesses the future prospects of bottom of the pyramid models in health. Methods We searched published and grey literature and databases to identify PFP companies that provided more than 40,000 outpatient visits per year, or who covered 15% or more of a particular type of service in their country. For each included provider, we searched for additional information on location, target market, business model and performance, including quality of care. Results Only 10 large scale PFP providers were identified. The majority of these were in South Asia and most provided specialized services such as eye care. The characteristics of the business models of these firms were found to be similar to non-profit providers studied by other analysts (such as Bhattacharya 2010). They pursued social rather than traditional marketing, partnerships with government, low cost/high volume services and cross-subsidization between different market segments. There was a lack of reliable data concerning these providers. Conclusions There is very limited evidence to support the notion that large scale bottom of the pyramid models in health offer good prospects for extending services to the poor in the future. In order to be successful PFP providers often require partnerships with government or support from social health insurance schemes. Nonetheless, more reliable and independent data on such schemes is needed. PMID:24961496

  7. Testing genotyping strategies for ultra-deep sequencing of a co-amplifying gene family: MHC class I in a passerine bird.

    PubMed

    Biedrzycka, Aleksandra; Sebastian, Alvaro; Migalska, Magdalena; Westerdahl, Helena; Radwan, Jacek

    2017-07-01

    Characterization of highly duplicated genes, such as genes of the major histocompatibility complex (MHC), where multiple loci often co-amplify, has until recently been hindered by insufficient read depths per amplicon. Here, we used ultra-deep Illumina sequencing to resolve genotypes at exon 3 of MHC class I genes in the sedge warbler (Acrocephalus schoenobaenus). We sequenced 24 individuals in two replicates and used this data, as well as a simulated data set, to test the effect of amplicon coverage (range: 500-20 000 reads per amplicon) on the repeatability of genotyping using four different genotyping approaches. A third replicate employed unique barcoding to assess the extent of tag jumping, that is swapping of individual tag identifiers, which may confound genotyping. The reliability of MHC genotyping increased with coverage and approached or exceeded 90% within-method repeatability of allele calling at coverages of >5000 reads per amplicon. We found generally high agreement between genotyping methods, especially at high coverages. High reliability of the tested genotyping approaches was further supported by our analysis of the simulated data set, although the genotyping approach relying primarily on replication of variants in independent amplicons proved sensitive to repeatable errors. According to the most repeatable genotyping method, the number of co-amplifying variants per individual ranged from 19 to 42. Tag jumping was detectable, but at such low frequencies that it did not affect the reliability of genotyping. We thus demonstrate that gene families with many co-amplifying genes can be reliably genotyped using HTS, provided that there is sufficient per amplicon coverage. © 2016 John Wiley & Sons Ltd.

  8. SABRE: a bio-inspired fault-tolerant electronic architecture.

    PubMed

    Bremner, P; Liu, Y; Samie, M; Dragffy, G; Pipe, A G; Tempesti, G; Timmis, J; Tyrrell, A M

    2013-03-01

    As electronic devices become increasingly complex, ensuring their reliable, fault-free operation is becoming correspondingly more challenging. It can be observed that, in spite of their complexity, biological systems are highly reliable and fault tolerant. Hence, we are motivated to take inspiration for biological systems in the design of electronic ones. In SABRE (self-healing cellular architectures for biologically inspired highly reliable electronic systems), we have designed a bio-inspired fault-tolerant hierarchical architecture for this purpose. As in biology, the foundation for the whole system is cellular in nature, with each cell able to detect faults in its operation and trigger intra-cellular or extra-cellular repair as required. At the next level in the hierarchy, arrays of cells are configured and controlled as function units in a transport triggered architecture (TTA), which is able to perform partial-dynamic reconfiguration to rectify problems that cannot be solved at the cellular level. Each TTA is, in turn, part of a larger multi-processor system which employs coarser grain reconfiguration to tolerate faults that cause a processor to fail. In this paper, we describe the details of operation of each layer of the SABRE hierarchy, and how these layers interact to provide a high systemic level of fault tolerance.

  9. Error control techniques for satellite and space communications

    NASA Technical Reports Server (NTRS)

    Costello, D. J., Jr.

    1986-01-01

    High rate concatenated coding systems with trellis inner codes and Reed-Solomon (RS) outer codes for application in satellite communication systems are considered. Two types of inner codes are studied: high rate punctured binary convolutional codes which result in overall effective information rates between 1/2 and 1 bit per channel use; and bandwidth efficient signal space trellis codes which can achieve overall effective information rates greater than 1 bit per channel use. Channel capacity calculations with and without side information performed for the concatenated coding system. Concatenated coding schemes are investigated. In Scheme 1, the inner code is decoded with the Viterbi algorithm and the outer RS code performs error-correction only (decoding without side information). In scheme 2, the inner code is decoded with a modified Viterbi algorithm which produces reliability information along with the decoded output. In this algorithm, path metrics are used to estimate the entire information sequence, while branch metrics are used to provide the reliability information on the decoded sequence. This information is used to erase unreliable bits in the decoded output. An errors-and-erasures RS decoder is then used for the outer code. These two schemes are proposed for use on NASA satellite channels. Results indicate that high system reliability can be achieved with little or no bandwidth expansion.

  10. Comparison of disease activity measures for anti-neutrophil cytoplasmic autoantibody (ANCA)-associated vasculitis.

    PubMed

    Merkel, P A; Cuthbertson, D D; Hellmich, B; Hoffman, G S; Jayne, D R W; Kallenberg, C G M; Krischer, J P; Luqmani, R; Mahr, A D; Matteson, E L; Specks, U; Stone, J H

    2009-01-01

    Currently, several different instruments are used to measure disease activity and extent in clinical trials of anti-neutrophil cytoplasmic autoantibody (ANCA)-associated vasculitis, leading to division among investigative groups and difficulty comparing study results. An exercise comparing six different vasculitis instruments was performed. A total of 10 experienced vasculitis investigators from 5 countries scored 20 cases in the literature of Wegener granulomatosis or microscopic polyangiitis using 6 disease assessment tools: the Birmingham Vasculitis Activity Score (BVAS), The BVAS for Wegener granulomatosis (BVAS/WG), BVAS 2003, a Physician Global Assessment (PGA), the Disease Extent Index (DEI) and the Five Factor Score (FFS). Five cases were rescored by all raters. Reliability of the measures was extremely high (intraclass correlations for the six measures all = 0.98). Within each instrument, there were no significant differences or outliers among the scores from the 10 investigators. Test/retest reliability was high for each measure: range = 0.77 to 0.95. The scores of the five acute activity measures correlated extremely well with one another. Currently available tools for measuring disease extent and activity in ANCA-associated vasculitis are highly correlated and reliable. These results provide investigators with confidence to compare different clinical trial data and helps form common ground as international research groups develop new, improved and universally accepted vasculitis disease assessment instruments.

  11. Modular Stirling Radioisotope Generator

    NASA Technical Reports Server (NTRS)

    Schmitz, Paul C.; Mason, Lee S.; Schifer, Nicholas A.

    2016-01-01

    High-efficiency radioisotope power generators will play an important role in future NASA space exploration missions. Stirling Radioisotope Generators (SRGs) have been identified as a candidate generator technology capable of providing mission designers with an efficient, high-specific-power electrical generator. SRGs high conversion efficiency has the potential to extend the limited Pu-238 supply when compared with current Radioisotope Thermoelectric Generators (RTGs). Due to budgetary constraints, the Advanced Stirling Radioisotope Generator (ASRG) was canceled in the fall of 2013. Over the past year a joint study by NASA and the Department of Energy (DOE) called the Nuclear Power Assessment Study (NPAS) recommended that Stirling technologies continue to be explored. During the mission studies of the NPAS, spare SRGs were sometimes required to meet mission power system reliability requirements. This led to an additional mass penalty and increased isotope consumption levied on certain SRG-based missions. In an attempt to remove the spare power system, a new generator architecture is considered, which could increase the reliability of a Stirling generator and provide a more fault-tolerant power system. This new generator called the Modular Stirling Radioisotope Generator (MSRG) employs multiple parallel Stirling convertor/controller strings, all of which share the heat from the General Purpose Heat Source (GPHS) modules. For this design, generators utilizing one to eight GPHS modules were analyzed, which provided about 50 to 450 W of direct current (DC) to the spacecraft, respectively. Four Stirling convertors are arranged around each GPHS module resulting in from 4 to 32 Stirling/controller strings. The convertors are balanced either individually or in pairs, and are radiatively coupled to the GPHS modules. Heat is rejected through the housing/radiator, which is similar in construction to the ASRG. Mass and power analysis for these systems indicate that specific power may be slightly lower than the ASRG and similar to the Multi-Mission Radioisotope Thermoelectric Generator (MMRTG). However, the reliability should be significantly increased compared to ASRG.

  12. Modular Stirling Radioisotope Generator

    NASA Technical Reports Server (NTRS)

    Schmitz, Paul C.; Mason, Lee S.; Schifer, Nicholas A.

    2015-01-01

    High efficiency radioisotope power generators will play an important role in future NASA space exploration missions. Stirling Radioisotope Generators (SRG) have been identified as a candidate generator technology capable of providing mission designers with an efficient, high specific power electrical generator. SRGs high conversion efficiency has the potential to extend the limited Pu-238 supply when compared with current Radioisotope Thermoelectric Generators (RTG). Due to budgetary constraints, the Advanced Stirling Radioisotope Generator (ASRG) was canceled in the fall of 2013. Over the past year a joint study by NASA and DOE called the Nuclear Power Assessment Study (NPAS) recommended that Stirling technologies continue to be explored. During the mission studies of the NPAS, spare SRGs were sometimes required to meet mission power system reliability requirements. This led to an additional mass penalty and increased isotope consumption levied on certain SRG-based missions. In an attempt to remove the spare power system, a new generator architecture is considered which could increase the reliability of a Stirling generator and provide a more fault-tolerant power system. This new generator called the Modular Stirling Radioisotope Generator (MSRG) employs multiple parallel Stirling convertor/controller strings, all of which share the heat from the General Purpose Heat Source (GPHS) modules. For this design, generators utilizing one to eight GPHS modules were analyzed, which provide about 50 to 450 watts DC to the spacecraft, respectively. Four Stirling convertors are arranged around each GPHS module resulting in from 4 to 32 Stirling/controller strings. The convertors are balanced either individually or in pairs, and are radiatively coupled to the GPHS modules. Heat is rejected through the housing/radiator which is similar in construction to the ASRG. Mass and power analysis for these systems indicate that specific power may be slightly lower than the ASRG and similar to the MMRTG. However, the reliability should be significantly increased compared to ASRG.

  13. Quantification of dopamine transporters in the mouse brain using ultra-high resolution single-photon emission tomography.

    PubMed

    Acton, Paul D; Choi, Seok-Rye; Plössl, Karl; Kung, Hank F

    2002-05-01

    Functional imaging of small animals, such as mice and rats, using ultra-high resolution positron emission tomography (PET) and single-photon emission tomography (SPET), is becoming a valuable tool for studying animal models of human disease. While several studies have shown the utility of PET imaging in small animals, few have used SPET in real research applications. In this study we aimed to demonstrate the feasibility of using ultra-high resolution SPET in quantitative studies of dopamine transporters (DAT) in the mouse brain. Four healthy ICR male mice were injected with (mean+/-SD) 704+/-154 MBq [(99m)Tc]TRODAT-1, and scanned using an ultra-high resolution SPET system equipped with pinhole collimators (spatial resolution 0.83 mm at 3 cm radius of rotation). Each mouse had two studies, to provide an indication of test-retest reliability. Reference tissue kinetic modeling analysis of the time-activity data in the striatum and cerebellum was used to quantitate the availability of DAT. A simple equilibrium ratio of striatum to cerebellum provided another measure of DAT binding. The SPET imaging results were compared against ex vivo biodistribution data from the striatum and cerebellum. The mean distribution volume ratio (DVR) from the reference tissue kinetic model was 2.17+/-0.34, with a test-retest reliability of 2.63%+/-1.67%. The ratio technique gave similar results (DVR=2.03+/-0.38, test-retest reliability=6.64%+/-3.86%), and the ex vivo analysis gave DVR=2.32+/-0.20. Correlations between the kinetic model and the ratio technique ( R(2)=0.86, P<0.001) and the ex vivo data ( R(2)=0.92, P=0.04) were both excellent. This study demonstrated clearly that ultra-high resolution SPET of small animals is capable of accurate, repeatable, and quantitative measures of DAT binding, and should open up the possibility of further studies of cerebral binding sites in mice using pinhole SPET.

  14. Evaluation of Reliability Coefficients for Two-Level Models via Latent Variable Analysis

    ERIC Educational Resources Information Center

    Raykov, Tenko; Penev, Spiridon

    2010-01-01

    A latent variable analysis procedure for evaluation of reliability coefficients for 2-level models is outlined. The method provides point and interval estimates of group means' reliability, overall reliability of means, and conditional reliability. In addition, the approach can be used to test simple hypotheses about these parameters. The…

  15. Transit Reliability Information Program : Reliability Verification Demonstration Plan for Rapid Rail Vehicles

    DOT National Transportation Integrated Search

    1981-08-01

    The Transit Reliability Information Program (TRIP) is a government-initiated program to assist the transit industry in satisfying its need for transit reliability information. TRIP provides this assistance through the operation of a national Data Ban...

  16. Development of a reliable method to assess footwear comfort during running.

    PubMed

    Mündermann, Anne; Nigg, Benno M; Stefanyshyn, Darren J; Humble, R Neil

    2002-08-01

    The purposes of this study were: (a) to determine whether subjects are able to distinguish between differences in footwear with respect to footwear comfort; and (b) to determine how reliably footwear comfort can be assessed using a visual analogue scale (VAS) and a protocol including a control condition during running. Intraclass correlation coefficients (ICCs) between comfort ratings for repeated conditions were high (ICC = 0.799). Differences in comfort ratings between the insert conditions were significant. A paired t-test revealed a significant difference in overall comfort ratings for the control insert when tested after the soft insert compared to when tested after the hard insert (P = 0.008). The results of this study showed that VASs provide a reliable measure to assess footwear comfort during running under the conditions that: (a) a control condition is included; and (b) the average comfort rating of sessions 4-6 is used. Copyright 2002 Elsevier Science B.V.

  17. Accurate, robust and reliable calculations of Poisson-Boltzmann binding energies

    PubMed Central

    Nguyen, Duc D.; Wang, Bao

    2017-01-01

    Poisson-Boltzmann (PB) model is one of the most popular implicit solvent models in biophysical modeling and computation. The ability of providing accurate and reliable PB estimation of electrostatic solvation free energy, ΔGel, and binding free energy, ΔΔGel, is important to computational biophysics and biochemistry. In this work, we investigate the grid dependence of our PB solver (MIBPB) with SESs for estimating both electrostatic solvation free energies and electrostatic binding free energies. It is found that the relative absolute error of ΔGel obtained at the grid spacing of 1.0 Å compared to ΔGel at 0.2 Å averaged over 153 molecules is less than 0.2%. Our results indicate that the use of grid spacing 0.6 Å ensures accuracy and reliability in ΔΔGel calculation. In fact, the grid spacing of 1.1 Å appears to deliver adequate accuracy for high throughput screening. PMID:28211071

  18. Psychometric testing of the modified Care Dependency Scale among hospitalized school-aged children in Germany.

    PubMed

    Tork, Hanan; Lohrmann, Christa; Dassen, Theo

    2008-03-01

    The objectives of this study were to examine the psychometric properties of the modified Care Dependency Scale in a pediatric setting and to explore the extent of dependency of school-aged children regarding their self-care. The data were collected from 130 hospitalized children, aged 6-12 years. The reliability was determined by Cronbach's alpha, which showed a high level of consistency. The subsequent inter-rater reliability revealed moderate-to-substantial agreement. The criterion-related validity was tested by comparing the sum scores of the Care Dependency Scale for Paediatrics and the Visual Analog Scale. Factor analysis was used to investigate the construct validity and resulted in a one-factor solution. In conclusion, this study provides evidence that the Care Dependency Scale for Paediatrics is a valid and reliable measure that offers a comprehensive assessment from a nursing perspective and enables nurses to help children acquire independence.

  19. A Robust Compositional Architecture for Autonomous Systems

    NASA Technical Reports Server (NTRS)

    Brat, Guillaume; Deney, Ewen; Farrell, Kimberley; Giannakopoulos, Dimitra; Jonsson, Ari; Frank, Jeremy; Bobby, Mark; Carpenter, Todd; Estlin, Tara

    2006-01-01

    Space exploration applications can benefit greatly from autonomous systems. Great distances, limited communications and high costs make direct operations impossible while mandating operations reliability and efficiency beyond what traditional commanding can provide. Autonomous systems can improve reliability and enhance spacecraft capability significantly. However, there is reluctance to utilizing autonomous systems. In part this is due to general hesitation about new technologies, but a more tangible concern is that of reliability of predictability of autonomous software. In this paper, we describe ongoing work aimed at increasing robustness and predictability of autonomous software, with the ultimate goal of building trust in such systems. The work combines state-of-the-art technologies and capabilities in autonomous systems with advanced validation and synthesis techniques. The focus of this paper is on the autonomous system architecture that has been defined, and on how it enables the application of validation techniques for resulting autonomous systems.

  20. Shuttle-Derived Launch Vehicles' Capablities: An Overview

    NASA Technical Reports Server (NTRS)

    Rothschild, William J.; Bailey, Debra A.; Henderson, Edward M.; Crumbly, Chris

    2005-01-01

    Shuttle-Derived Launch Vehicle (SDLV) concepts have been developed by a collaborative team comprising the Johnson Space Center, Marshall Space Flight Center, Kennedy Space Center, ATK-Thiokol, Lockheed Martin Space Systems Company, The Boeing Company, and United Space Alliance. The purpose of this study was to provide timely information on a full spectrum of low-risk, cost-effective options for STS-Derived Launch Vehicle concepts to support the definition of crew and cargo launch requirements for the Space Exploration Vision. Since the SDLV options use high-reliability hardware, existing facilities, and proven processes, they can provide relatively low-risk capabilities to launch extremely large payloads to low Earth orbit. This capability to reliably lift very large, high-dollar-value payloads could reduce mission operational risks by minimizing the number of complex on-orbit operations compared to architectures based on multiple smaller launchers. The SDLV options also offer several logical spiral development paths for larger exploration payloads. All of these development paths make practical and cost-effective use of existing Space Shuttle Program (SSP) hardware, infrastructure, and launch and flight operations systems. By utilizing these existing assets, the SDLV project could support the safe and orderly transition of the current SSP through the planned end of life in 2010. The SDLV concept definition work during 2004 focused on three main configuration alternatives: a side-mount heavy lifter (approximately 77 MT payload), an in-line medium lifter (approximately 22 MT Crew Exploration Vehicle payload), and an in-line heavy lifter (greater than 100 MT payload). This paper provides an overview of the configuration, performance capabilities, reliability estimates, concept of operations, and development plans for each of the various SDLV alternatives. While development, production, and operations costs have been estimated for each of the SDLV configuration alternatives, these proprietary data have not been included in this paper.

Top