The Effect of Incorrect Reliability Information on Expectations, Perceptions, and Use of Automation.
Barg-Walkow, Laura H; Rogers, Wendy A
2016-03-01
We examined how providing artificially high or low statements about automation reliability affected expectations, perceptions, and use of automation over time. One common method of introducing automation is providing explicit statements about the automation's capabilities. Research is needed to understand how expectations from such introductions affect perceptions and use of automation. Explicit-statement introductions were manipulated to set higher-than (90%), same-as (75%), or lower-than (60%) levels of expectations in a dual-task scenario with 75% reliable automation. Two experiments were conducted to assess expectations, perceptions, compliance, reliance, and task performance over (a) 2 days and (b) 4 days. The baseline assessments showed initial expectations of automation reliability matched introduced levels of expectation. For the duration of each experiment, the lower-than groups' perceptions were lower than the actual automation reliability. However, the higher-than groups' perceptions were no different from actual automation reliability after Day 1 in either study. There were few differences between groups for automation use, which generally stayed the same or increased with experience using the system. Introductory statements describing artificially low automation reliability have a long-lasting impact on perceptions about automation performance. Statements including incorrect automation reliability do not appear to affect use of automation. Introductions should be designed according to desired outcomes for expectations, perceptions, and use of the automation. Low expectations have long-lasting effects. © 2015, Human Factors and Ergonomics Society.
High-Reliability Pump Module for Non-Planar Ring Oscillator Laser
NASA Technical Reports Server (NTRS)
Liu, Duncan T.; Qiu, Yueming; Wilson, Daniel W.; Dubovitsky, Serge; Forouhar, Siamak
2007-01-01
We propose and have demonstrated a prototype high-reliability pump module for pumping a Non-Planar Ring Oscillator (NPRO) laser suitable for space missions. The pump module consists of multiple fiber-coupled single-mode laser diodes and a fiber array micro-lens array based fiber combiner. The reported Single-Mode laser diode combiner laser pump module (LPM) provides a higher normalized brightness at the combined beam than multimode laser diode based LPMs. A higher brightness from the pump source is essential for efficient NPRO laser pumping and leads to higher reliability because higher efficiency requires a lower operating power for the laser diodes, which in turn increases the reliability and lifetime of the laser diodes. Single-mode laser diodes with Fiber Bragg Grating (FBG) stabilized wavelength permit the pump module to be operated without a thermal electric cooler (TEC) and this further improves the overall reliability of the pump module. The single-mode laser diode LPM is scalable in terms of the number of pump diodes and is capable of combining hundreds of fiber-coupled laser diodes. In the proof-of-concept demonstration, an e-beam written diffractive micro lens array, a custom fiber array, commercial 808nm single mode laser diodes, and a custom NPRO laser head are used. The reliability of the proposed LPM is discussed.
Ultra Reliable Closed Loop Life Support for Long Space Missions
NASA Technical Reports Server (NTRS)
Jones, Harry W.; Ewert, Michael K.
2010-01-01
Spacecraft human life support systems can achieve ultra reliability by providing sufficient spares to replace all failed components. The additional mass of spares for ultra reliability is approximately equal to the original system mass, provided that the original system reliability is not too low. Acceptable reliability can be achieved for the Space Shuttle and Space Station by preventive maintenance and by replacing failed units. However, on-demand maintenance and repair requires a logistics supply chain in place to provide the needed spares. In contrast, a Mars or other long space mission must take along all the needed spares, since resupply is not possible. Long missions must achieve ultra reliability, a very low failure rate per hour, since they will take years rather than weeks and cannot be cut short if a failure occurs. Also, distant missions have a much higher mass launch cost per kilogram than near-Earth missions. Achieving ultra reliable spacecraft life support systems with acceptable mass will require a well-planned and extensive development effort. Analysis must determine the reliability requirement and allocate it to subsystems and components. Ultra reliability requires reducing the intrinsic failure causes, providing spares to replace failed components and having "graceful" failure modes. Technologies, components, and materials must be selected and designed for high reliability. Long duration testing is needed to confirm very low failure rates. Systems design should segregate the failure causes in the smallest, most easily replaceable parts. The system must be designed, developed, integrated, and tested with system reliability in mind. Maintenance and reparability of failed units must not add to the probability of failure. The overall system must be tested sufficiently to identify any design errors. A program to develop ultra reliable space life support systems with acceptable mass should start soon since it must be a long term effort.
NASA Astrophysics Data System (ADS)
Zhang, Zisheng; Li, Yanhu; Li, Jiaojiao; Liu, Zhiqiang; Li, Qing
2013-03-01
In order to improve the reliability, stability and automation of electrostatic precipitator, circuits of vibration motor for ESP and vibration control ladder diagram program are investigated using Schneider PLC with high performance and programming software of Twidosoft. Operational results show that after adopting PLC, vibration motor can run automatically; compared with traditional control system of vibration based on single-chip microcomputer, it has higher reliability, better stability and higher dust removal rate, when dust emission concentrations <= 50 mg m-3, providing a new method for vibration controlling of ESP.
Managing Complexity in Next Generation Robotic Spacecraft: From a Software Perspective
NASA Technical Reports Server (NTRS)
Reinholtz, Kirk
2008-01-01
This presentation highlights the challenges in the design of software to support robotic spacecraft. Robotic spacecraft offer a higher degree of autonomy, however currently more capabilities are required, primarily in the software, while providing the same or higher degree of reliability. The complexity of designing such an autonomous system is great, particularly while attempting to address the needs for increased capabilities and high reliability without increased needs for time or money. The efforts to develop programming models for the new hardware and the integration of software architecture are highlighted.
ERIC Educational Resources Information Center
Minter, W. John; Bowen, Howard R.
The fifth report in an annual series designed to provide timely and reliable information on the condition of the independent sector of American higher education is presented. Information was gathered from a sample of 127 institutions representative of all independent, nonprofit, accredited institutions, except free-standing professional schools…
Integrating Formal Methods and Testing 2002
NASA Technical Reports Server (NTRS)
Cukic, Bojan
2002-01-01
Traditionally, qualitative program verification methodologies and program testing are studied in separate research communities. None of them alone is powerful and practical enough to provide sufficient confidence in ultra-high reliability assessment when used exclusively. Significant advances can be made by accounting not only tho formal verification and program testing. but also the impact of many other standard V&V techniques, in a unified software reliability assessment framework. The first year of this research resulted in the statistical framework that, given the assumptions on the success of the qualitative V&V and QA procedures, significantly reduces the amount of testing needed to confidently assess reliability at so-called high and ultra-high levels (10-4 or higher). The coming years shall address the methodologies to realistically estimate the impacts of various V&V techniques to system reliability and include the impact of operational risk to reliability assessment. Combine formal correctness verification, process and product metrics, and other standard qualitative software assurance methods with statistical testing with the aim of gaining higher confidence in software reliability assessment for high-assurance applications. B) Quantify the impact of these methods on software reliability. C) Demonstrate that accounting for the effectiveness of these methods reduces the number of tests needed to attain certain confidence level. D) Quantify and justify the reliability estimate for systems developed using various methods.
Estimate of the Reliability in Geological Forecasts for Tunnels: Toward a Structured Approach
NASA Astrophysics Data System (ADS)
Perello, Paolo
2011-11-01
In tunnelling, a reliable geological model often allows providing an effective design and facing the construction phase without unpleasant surprises. A geological model can be considered reliable when it is a valid support to correctly foresee the rock mass behaviour, therefore preventing unexpected events during the excavation. The higher the model reliability, the lower the probability of unforeseen rock mass behaviour. Unfortunately, owing to different reasons, geological models are affected by uncertainties and a fully reliable knowledge of the rock mass is, in most cases, impossible. Therefore, estimating to which degree a geological model is reliable, becomes a primary requirement in order to save time and money and to adopt the appropriate construction strategy. The definition of the geological model reliability is often achieved by engineering geologists through an unstructured analytical process and variable criteria. This paper focusses on geological models for projects of linear underground structures and represents an effort to analyse and include in a conceptual framework the factors influencing such models. An empirical parametric procedure is then developed with the aim of obtaining an index called "geological model rating (GMR)", which can be used to provide a more standardised definition of a geological model reliability.
Lord, Sarah Peregrine; Can, Doğan; Yi, Michael; Marin, Rebeca; Dunn, Christopher W.; Imel, Zac E.; Georgiou, Panayiotis; Narayanan, Shrikanth; Steyvers, Mark; Atkins, David C.
2014-01-01
The current paper presents novel methods for collecting MISC data and accurately assessing reliability of behavior codes at the level of the utterance. The MISC 2.1 was used to rate MI interviews from five randomized trials targeting alcohol and drug use. Sessions were coded at the utterance-level. Utterance-based coding reliability was estimated using three methods and compared to traditional reliability estimates of session tallies. Session-level reliability was generally higher compared to reliability using utterance-based codes, suggesting that typical methods for MISC reliability may be biased. These novel methods in MI fidelity data collection and reliability assessment provided rich data for therapist feedback and further analyses. Beyond implications for fidelity coding, utterance-level coding schemes may elucidate important elements in the counselor-client interaction that could inform theories of change and the practice of MI. PMID:25242192
Lord, Sarah Peregrine; Can, Doğan; Yi, Michael; Marin, Rebeca; Dunn, Christopher W; Imel, Zac E; Georgiou, Panayiotis; Narayanan, Shrikanth; Steyvers, Mark; Atkins, David C
2015-02-01
The current paper presents novel methods for collecting MISC data and accurately assessing reliability of behavior codes at the level of the utterance. The MISC 2.1 was used to rate MI interviews from five randomized trials targeting alcohol and drug use. Sessions were coded at the utterance-level. Utterance-based coding reliability was estimated using three methods and compared to traditional reliability estimates of session tallies. Session-level reliability was generally higher compared to reliability using utterance-based codes, suggesting that typical methods for MISC reliability may be biased. These novel methods in MI fidelity data collection and reliability assessment provided rich data for therapist feedback and further analyses. Beyond implications for fidelity coding, utterance-level coding schemes may elucidate important elements in the counselor-client interaction that could inform theories of change and the practice of MI. Copyright © 2015 Elsevier Inc. All rights reserved.
Real-Time Aggressive Image Data Compression
1990-03-31
implemented with higher degrees of modularity, concurrency, and higher levels of machine intelligence , thereby providing higher data -throughput rates...Project Summary Project Title: Real-Time Aggressive Image Data Compression Principal Investigators: Dr. Yih-Fang Huang and Dr. Ruey-wen Liu Institution...Summary The objective of the proposed research is to develop reliable algorithms !.hat can achieve aggressive image data compression (with a compression
ERIC Educational Resources Information Center
Grammatikopoulos, Vasilis; Linardakis, M.; Gregoriadis, A.; Oikonomidis, V.
2015-01-01
The aim of the current study was to provide a valid and reliable instrument for the evaluation of the teaching effectiveness in the Greek higher education system. Other objectives of the study were (a) the examination of the dimensionality and the higher-order structure of the Greek version of Students' Evaluation of Educational Quality (SEEQ)…
Introduction: tagging, telemetry, and Marking Compendium Project: Chapter 1
Wolf, S; Waste, Stephen M.
2010-01-01
• Increase the opportunity for data collection to provide more reliable information and result in improved analyses and higher confidence in data analyses for making informed and more relevant decisions.
Older males signal more reliably.
Proulx, Stephen R; Day, Troy; Rowe, Locke
2002-01-01
The hypothesis that females prefer older males because they have higher mean fitness than younger males has been the centre of recent controversy. These discussions have focused on the success of a female who prefers males of a particular age class when age cues, but not quality cues, are available. Thus, if the distribution of male quality changes with age, such that older males have on average genotypes with higher fitness than younger males, then a female who mates with older males has fitter offspring, which allows the female preference to spread through a genetic correlation. We develop a general model for male display in a species with multiple reproductive bouts that allows us to identify the conditions that promote reliable signalling within an age class. Because males have opportunities for future reproduction, they will reduce their levels of advertising compared with a semelparous species. In addition, because higher-quality males have more future reproduction, they will reduce their advertising more than low-quality males. Thus, the conditions for reliable signalling in a semelparous organism are generally not sufficient to produce reliable signalling in species with multiple reproductive bouts. This result is due to the possibility of future reproduction so that, as individuals age and the opportunities for future reproduction fade, signalling becomes more reliable. This provides a novel rationale for female preference for older mates; older males reveal more information in their sexual displays. PMID:12495495
Redundant disk arrays: Reliable, parallel secondary storage. Ph.D. Thesis
NASA Technical Reports Server (NTRS)
Gibson, Garth Alan
1990-01-01
During the past decade, advances in processor and memory technology have given rise to increases in computational performance that far outstrip increases in the performance of secondary storage technology. Coupled with emerging small-disk technology, disk arrays provide the cost, volume, and capacity of current disk subsystems, by leveraging parallelism, many times their performance. Unfortunately, arrays of small disks may have much higher failure rates than the single large disks they replace. Redundant arrays of inexpensive disks (RAID) use simple redundancy schemes to provide high data reliability. The data encoding, performance, and reliability of redundant disk arrays are investigated. Organizing redundant data into a disk array is treated as a coding problem. Among alternatives examined, codes as simple as parity are shown to effectively correct single, self-identifying disk failures.
Reliability in individual monitoring service.
Mod Ali, N
2011-03-01
As a laboratory certified to ISO 9001:2008 and accredited to ISO/IEC 17025, the Secondary Standard Dosimetry Laboratory (SSDL)-Nuclear Malaysia has incorporated an overall comprehensive system for technical and quality management in promoting a reliable individual monitoring service (IMS). Faster identification and resolution of issues regarding dosemeter preparation and issuing of reports, personnel enhancement, improved customer satisfaction and overall efficiency of laboratory activities are all results of the implementation of an effective quality system. Review of these measures and responses to observed trends provide continuous improvement of the system. By having these mechanisms, reliability of the IMS can be assured in the promotion of safe behaviour at all levels of the workforce utilising ionising radiation facilities. Upgradation of in the reporting program through a web-based e-SSDL marks a major improvement in Nuclear Malaysia's IMS reliability on the whole. The system is a vital step in providing a user friendly and effective occupational exposure evaluation program in the country. It provides a higher level of confidence in the results generated for occupational dose monitoring of the IMS, thus, enhances the status of the radiation protection framework of the country.
Marawar, Satyajit V; Madom, Ian A; Palumbo, Mark; Tallarico, Richard A; Ordway, Nathaniel R; Metkar, Umesh; Wang, Dongliang; Green, Adam; Lavelle, William F
2017-01-01
Treating surgeon's visual assessment of axial MRI images to ascertain the degree of stenosis has a critical impact on surgical decision-making. The purpose of this study was to prospectively analyze the impact of surgeon experience on inter-observer and intra-observer reliability of assessing severity of spinal stenosis on MRIs by spine surgeons directly involved in surgical decision-making. Seven fellowship trained spine surgeons reviewed MRI studies of 30 symptomatic patients with lumbar stenosis and graded the stenosis in the central canal, the lateral recess and the foramen at T12-L1 to L5-S1 as none, mild, moderate or severe. No specific instructions were provided to what constituted mild, moderate, or severe stenosis. Two surgeons were "senior" (>fifteen years of practice experience); two were "intermediate" (>four years of practice experience), and three "junior" (< one year of practice experience). The concordance correlation coefficient (CCC) was calculated to assess inter-observer reliability. Seven MRI studies were duplicated and randomly re-read to evaluate inter-observer reliability. Surgeon experience was found to be a strong predictor of inter-observer reliability. Senior inter-observer reliability was significantly higher assessing central(p<0.001), foraminal p=0.005 and lateral p=0.001 than "junior" group.Senior group also showed significantly higher inter-observer reliability that intermediate group assessing foraminal stenosis (p=0.036). In intra-observer reliability the results were contrary to that found in inter-observer reliability. Inter-observer reliability of assessing stenosis on MRIs increases with surgeon experience. Lower intra-observer reliability values among the senior group, although not clearly explained, may be due to the small number of MRIs evaluated and quality of MRI images.Level of evidence: Level 3.
The use of tobacco tax revenues to fund the Guam Cancer Registry: A double win for cancer control.
David, Annette M; Haddock, Robert L; Bordallo, Renata; Dirige, Janet T; Mery, Les
2017-06-01
Cancer registries that provide reliable data on cancer incidence, mortality and burden are essential to cancer control. However, establishing sustainable local funding mechanisms to support cancer registries remains a challenge in many countries. Guam, an unincorporated Territory of the United States of America in the Western Pacific, enacted a bill that raised tobacco taxes, and earmarked a percentage of tobacco tax revenues to support its Cancer Registry. This provided a reliable funding stream for the Registry, allowing for continued staffing and capacity building; at the same time, youth tobacco consumption decreased following the tax increase. Linking tobacco tax revenues to cancer registry support is a feasible strategy with a double benefit: higher tobacco prices from higher tobacco taxes reduce tobacco-related cancer risk while assuring the long-term viability of systematic cancer data collection and dissemination.
The use of tobacco tax revenues to fund the Guam Cancer Registry: A double win for cancer control
David, Annette M.; Haddock, Robert L; Bordallo, Renata; Dirige, Janet T.; Mery, Les
2017-01-01
Cancer registries that provide reliable data on cancer incidence, mortality and burden are essential to cancer control. However, establishing sustainable local funding mechanisms to support cancer registries remains a challenge in many countries. Guam, an unincorporated Territory of the United States of America in the Western Pacific, enacted a bill that raised tobacco taxes, and earmarked a percentage of tobacco tax revenues to support its Cancer Registry. This provided a reliable funding stream for the Registry, allowing for continued staffing and capacity building; at the same time, youth tobacco consumption decreased following the tax increase. Linking tobacco tax revenues to cancer registry support is a feasible strategy with a double benefit: higher tobacco prices from higher tobacco taxes reduce tobacco-related cancer risk while assuring the long-term viability of systematic cancer data collection and dissemination. PMID:29130031
Perceived Transcultural Self-Efficacy of Nurses in General Hospitals in Guangzhou, China
Li, Juan; He, Zhuang; Luo, Yong; Zhang, Rong
2016-01-01
Background Conflicts arising from cultural diversity among patients and hospital staff in China have become intense. Hospitals have an urgent need to improve transcultural self-efficacy of nurses for providing effective transcultural nursing. Objective The purpose of the research was to (a) evaluate the current status of perceived transcultural self-efficacy of nurses in general hospitals in Guangzhou, China; (b) explore associations between demographic characteristics of nurses and their perceived transcultural self-efficacy; and (c) assess the reliability and validity of scores on the Chinese version of the Transcultural Self-Efficacy Tool (TSET). Methods A cross-sectional survey of registered nurses from three general hospitals was conducted. Quota and convenience sampling were used. Participants provided demographic information and answered questions on the TSET. Results A total of 1,156 registered nurses took part. Most nurses had a moderate level of self-efficacy on the Cognitive (87.9%), Practical (87%), and Affective (89.2%) TSET subscales. Nurses who were older; who had more years of work experience, higher professional titles, higher incomes, and a minority background; and who were officially employed (not temporary positions) had higher perceived transcultural self-efficacy. Reliability estimated using Cronbach’s alpha was .99 for the total TSET score; reliability for the three subscales ranged from .97 to .98. Confirmatory factor analysis of TSET scores showed good fit with a three-factor model. Conclusion The results of this study can provide insights and guidelines for hospital nursing management to facilitate design of in-service education systems to improve transcultural self-efficacy of nurses. PMID:27454552
High resolution time interval meter
Martin, A.D.
1986-05-09
Method and apparatus are provided for measuring the time interval between two events to a higher resolution than reliability available from conventional circuits and component. An internal clock pulse is provided at a frequency compatible with conventional component operating frequencies for reliable operation. Lumped constant delay circuits are provided for generating outputs at delay intervals corresponding to the desired high resolution. An initiation START pulse is input to generate first high resolution data. A termination STOP pulse is input to generate second high resolution data. Internal counters count at the low frequency internal clock pulse rate between the START and STOP pulses. The first and second high resolution data are logically combined to directly provide high resolution data to one counter and correct the count in the low resolution counter to obtain a high resolution time interval measurement.
Predictors of validity and reliability of a physical activity record in adolescents
2013-01-01
Background Poor to moderate validity of self-reported physical activity instruments is commonly observed in young people in low- and middle-income countries. However, the reasons for such low validity have not been examined in detail. We tested the validity of a self-administered daily physical activity record in adolescents and assessed if personal characteristics or the convenience level of reporting physical activity modified the validity estimates. Methods The study comprised a total of 302 adolescents from an urban and rural area in Ecuador. Validity was evaluated by comparing the record with accelerometer recordings for seven consecutive days. Test-retest reliability was examined by comparing registrations from two records administered three weeks apart. Time spent on sedentary (SED), low (LPA), moderate (MPA) and vigorous (VPA) intensity physical activity was estimated. Bland Altman plots were used to evaluate measurement agreement. We assessed if age, sex, urban or rural setting, anthropometry and convenience of completing the record explained differences in validity estimates using a linear mixed model. Results Although the record provided higher estimates for SED and VPA and lower estimates for LPA and MPA compared to the accelerometer, it showed an overall fair measurement agreement for validity. There was modest reliability for assessing physical activity in each intensity level. Validity was associated with adolescents’ personal characteristics: sex (SED: P = 0.007; LPA: P = 0.001; VPA: P = 0.009) and setting (LPA: P = 0.000; MPA: P = 0.047). Reliability was associated with the convenience of completing the physical activity record for LPA (low convenience: P = 0.014; high convenience: P = 0.045). Conclusions The physical activity record provided acceptable estimates for reliability and validity on a group level. Sex and setting were associated with validity estimates, whereas convenience to fill out the record was associated with better reliability estimates for LPA. This tendency of improved reliability estimates for adolescents reporting higher convenience merits further consideration. PMID:24289296
Developing Ultra Reliable Life Support for the Moon and Mars
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2009-01-01
Recycling life support systems can achieve ultra reliability by using spares to replace failed components. The added mass for spares is approximately equal to the original system mass, provided the original system reliability is not very low. Acceptable reliability can be achieved for the space shuttle and space station by preventive maintenance and by replacing failed units, However, this maintenance and repair depends on a logistics supply chain that provides the needed spares. The Mars mission must take all the needed spares at launch. The Mars mission also must achieve ultra reliability, a very low failure rate per hour, since it requires years rather than weeks and cannot be cut short if a failure occurs. Also, the Mars mission has a much higher mass launch cost per kilogram than shuttle or station. Achieving ultra reliable space life support with acceptable mass will require a well-planned and extensive development effort. Analysis must define the reliability requirement and allocate it to subsystems and components. Technologies, components, and materials must be designed and selected for high reliability. Extensive testing is needed to ascertain very low failure rates. Systems design should segregate the failure causes in the smallest, most easily replaceable parts. The systems must be designed, produced, integrated, and tested without impairing system reliability. Maintenance and failed unit replacement should not introduce any additional probability of failure. The overall system must be tested sufficiently to identify any design errors. A program to develop ultra reliable space life support systems with acceptable mass must start soon if it is to produce timely results for the moon and Mars.
Developing Reliable Life Support for Mars
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2017-01-01
A human mission to Mars will require highly reliable life support systems. Mars life support systems may recycle water and oxygen using systems similar to those on the International Space Station (ISS). However, achieving sufficient reliability is less difficult for ISS than it will be for Mars. If an ISS system has a serious failure, it is possible to provide spare parts, or directly supply water or oxygen, or if necessary bring the crew back to Earth. Life support for Mars must be designed, tested, and improved as needed to achieve high demonstrated reliability. A quantitative reliability goal should be established and used to guide development t. The designers should select reliable components and minimize interface and integration problems. In theory a system can achieve the component-limited reliability, but testing often reveal unexpected failures due to design mistakes or flawed components. Testing should extend long enough to detect any unexpected failure modes and to verify the expected reliability. Iterated redesign and retest may be required to achieve the reliability goal. If the reliability is less than required, it may be improved by providing spare components or redundant systems. The number of spares required to achieve a given reliability goal depends on the component failure rate. If the failure rate is under estimated, the number of spares will be insufficient and the system may fail. If the design is likely to have undiscovered design or component problems, it is advisable to use dissimilar redundancy, even though this multiplies the design and development cost. In the ideal case, a human tended closed system operational test should be conducted to gain confidence in operations, maintenance, and repair. The difficulty in achieving high reliability in unproven complex systems may require the use of simpler, more mature, intrinsically higher reliability systems. The limitations of budget, schedule, and technology may suggest accepting lower and less certain expected reliability. A plan to develop reliable life support is needed to achieve the best possible reliability.
Multi-version software reliability through fault-avoidance and fault-tolerance
NASA Technical Reports Server (NTRS)
Vouk, Mladen A.; Mcallister, David F.
1989-01-01
A number of experimental and theoretical issues associated with the practical use of multi-version software to provide run-time tolerance to software faults were investigated. A specialized tool was developed and evaluated for measuring testing coverage for a variety of metrics. The tool was used to collect information on the relationships between software faults and coverage provided by the testing process as measured by different metrics (including data flow metrics). Considerable correlation was found between coverage provided by some higher metrics and the elimination of faults in the code. Back-to-back testing was continued as an efficient mechanism for removal of un-correlated faults, and common-cause faults of variable span. Software reliability estimation methods was also continued based on non-random sampling, and the relationship between software reliability and code coverage provided through testing. New fault tolerance models were formulated. Simulation studies of the Acceptance Voting and Multi-stage Voting algorithms were finished and it was found that these two schemes for software fault tolerance are superior in many respects to some commonly used schemes. Particularly encouraging are the safety properties of the Acceptance testing scheme.
Edens, John F; Penson, Brittany N; Ruchensky, Jared R; Cox, Jennifer; Smith, Shannon Toney
2016-12-01
Published research suggests that most violence risk assessment tools have relatively high levels of interrater reliability, but recent evidence of inconsistent scores among forensic examiners in adversarial settings raises concerns about the "field reliability" of such measures. This study specifically examined the reliability of Violence Risk Appraisal Guide (VRAG) scores in Canadian criminal cases identified in the legal database, LexisNexis. Over 250 reported cases were located that made mention of the VRAG, with 42 of these cases containing 2 or more scores that could be submitted to interrater reliability analyses. Overall, scores were skewed toward higher risk categories. The intraclass correlation (ICCA1) was .66, with pairs of forensic examiners placing defendants into the same VRAG risk "bin" in 68% of the cases. For categorical risk statements (i.e., low, moderate, high), examiners provided converging assessment results in most instances (86%). In terms of potential predictors of rater disagreement, there was no evidence for adversarial allegiance in our sample. Rater disagreement in the scoring of 1 VRAG item (Psychopathy Checklist-Revised; Hare, 2003), however, strongly predicted rater disagreement in the scoring of the VRAG (r = .58). (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Analytical Micromechanics Modeling Technique Developed for Ceramic Matrix Composites Analysis
NASA Technical Reports Server (NTRS)
Min, James B.
2005-01-01
Ceramic matrix composites (CMCs) promise many advantages for next-generation aerospace propulsion systems. Specifically, carbon-reinforced silicon carbide (C/SiC) CMCs enable higher operational temperatures and provide potential component weight savings by virtue of their high specific strength. These attributes may provide systemwide benefits. Higher operating temperatures lessen or eliminate the need for cooling, thereby reducing both fuel consumption and the complex hardware and plumbing required for heat management. This, in turn, lowers system weight, size, and complexity, while improving efficiency, reliability, and service life, resulting in overall lower operating costs.
A Cross-Layer Optimized Opportunistic Routing Scheme for Loss-and-Delay Sensitive WSNs
Xu, Xin; Yuan, Minjiao; Liu, Xiao; Cai, Zhiping; Wang, Tian
2018-01-01
In wireless sensor networks (WSNs), communication links are typically error-prone and unreliable, so providing reliable and timely data routing for loss- and delay-sensitive applications in WSNs it is a challenge issue. Additionally, with specific thresholds in practical applications, the loss and delay sensitivity implies requirements for high reliability and low delay. Opportunistic Routing (OR) has been well studied in WSNs to improve reliability for error-prone and unreliable wireless communication links where the transmission power is assumed to be identical in the whole network. In this paper, a Cross-layer Optimized Opportunistic Routing (COOR) scheme is proposed to improve the communication link reliability and reduce delay for loss-and-delay sensitive WSNs. The main contribution of the COOR scheme is making full use of the remaining energy in networks to increase the transmission power of most nodes, which will provide a higher communication reliability or further transmission distance. Two optimization strategies referred to as COOR(R) and COOR(P) of the COOR scheme are proposed to improve network performance. In the case of increasing the transmission power, the COOR(R) strategy chooses a node that has a higher communication reliability with same distance in comparison to the traditional opportunistic routing when selecting the next hop candidate node. Since the reliability of data transmission is improved, the delay of the data reaching the sink is reduced by shortening the time of communication between candidate nodes. On the other hand, the COOR(P) strategy prefers a node that has the same communication reliability with longer distance. As a result, network performance can be improved for the following reasons: (a) the delay is reduced as fewer hops are needed while the packet reaches the sink in longer transmission distance circumstances; (b) the reliability can be improved since it is the product of the reliability of every hop of the routing path, and the count is reduced while the reliability of each hop is the same as the traditional method. After analyzing the energy consumption of the network in detail, the value of optimized transmission power in different areas is given. On the basis of a large number of experimental and theoretical analyses, the results show that the COOR scheme will increase communication reliability by 36.62–87.77%, decrease delay by 21.09–52.48%, and balance the energy consumption of 86.97% of the nodes in the WSNs. PMID:29751589
A Cross-Layer Optimized Opportunistic Routing Scheme for Loss-and-Delay Sensitive WSNs.
Xu, Xin; Yuan, Minjiao; Liu, Xiao; Liu, Anfeng; Xiong, Neal N; Cai, Zhiping; Wang, Tian
2018-05-03
In wireless sensor networks (WSNs), communication links are typically error-prone and unreliable, so providing reliable and timely data routing for loss- and delay-sensitive applications in WSNs it is a challenge issue. Additionally, with specific thresholds in practical applications, the loss and delay sensitivity implies requirements for high reliability and low delay. Opportunistic Routing (OR) has been well studied in WSNs to improve reliability for error-prone and unreliable wireless communication links where the transmission power is assumed to be identical in the whole network. In this paper, a Cross-layer Optimized Opportunistic Routing (COOR) scheme is proposed to improve the communication link reliability and reduce delay for loss-and-delay sensitive WSNs. The main contribution of the COOR scheme is making full use of the remaining energy in networks to increase the transmission power of most nodes, which will provide a higher communication reliability or further transmission distance. Two optimization strategies referred to as COOR(R) and COOR(P) of the COOR scheme are proposed to improve network performance. In the case of increasing the transmission power, the COOR(R) strategy chooses a node that has a higher communication reliability with same distance in comparison to the traditional opportunistic routing when selecting the next hop candidate node. Since the reliability of data transmission is improved, the delay of the data reaching the sink is reduced by shortening the time of communication between candidate nodes. On the other hand, the COOR(P) strategy prefers a node that has the same communication reliability with longer distance. As a result, network performance can be improved for the following reasons: (a) the delay is reduced as fewer hops are needed while the packet reaches the sink in longer transmission distance circumstances; (b) the reliability can be improved since it is the product of the reliability of every hop of the routing path, and the count is reduced while the reliability of each hop is the same as the traditional method. After analyzing the energy consumption of the network in detail, the value of optimized transmission power in different areas is given. On the basis of a large number of experimental and theoretical analyses, the results show that the COOR scheme will increase communication reliability by 36.62⁻87.77%, decrease delay by 21.09⁻52.48%, and balance the energy consumption of 86.97% of the nodes in the WSNs.
Revenue Sufficiency and Reliability in a Zero Marginal Cost Future
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frew, Bethany A.
Features of existing wholesale electricity markets, such as administrative pricing rules and policy-based reliability standards, can distort market incentives from allowing generators sufficient opportunities to recover both fixed and variable costs. Moreover, these challenges can be amplified by other factors, including (1) inelastic demand resulting from a lack of price signal clarity, (2) low- or near-zero marginal cost generation, particularly arising from low natural gas fuel prices and variable generation (VG), such as wind and solar, and (3) the variability and uncertainty of this VG. As power systems begin to incorporate higher shares of VG, many questions arise about themore » suitability of the existing marginal-cost-based price formation, primarily within an energy-only market structure, to ensure the economic viability of resources that might be needed to provide system reliability. This article discusses these questions and provides a summary of completed and ongoing modelling-based work at the National Renewable Energy Laboratory to better understand the impacts of evolving power systems on reliability and revenue sufficiency.« less
Revenue Sufficiency and Reliability in a Zero Marginal Cost Future: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frew, Bethany A.; Milligan, Michael; Brinkman, Greg
Features of existing wholesale electricity markets, such as administrative pricing rules and policy-based reliability standards, can distort market incentives from allowing generators sufficient opportunities to recover both fixed and variable costs. Moreover, these challenges can be amplified by other factors, including (1) inelastic demand resulting from a lack of price signal clarity, (2) low- or near-zero marginal cost generation, particularly arising from low natural gas fuel prices and variable generation (VG), such as wind and solar, and (3) the variability and uncertainty of this VG. As power systems begin to incorporate higher shares of VG, many questions arise about themore » suitability of the existing marginal-cost-based price formation, primarily within an energy-only market structure, to ensure the economic viability of resources that might be needed to provide system reliability. This article discusses these questions and provides a summary of completed and ongoing modelling-based work at the National Renewable Energy Laboratory to better understand the impacts of evolving power systems on reliability and revenue sufficiency.« less
Optical detection of metastatic cancer cells using a scanned laser pico-projection system
NASA Astrophysics Data System (ADS)
Huang, Chih-Ling; Chiu, Wen-Tai; Lo, Yu-Lung; Chuang, Chin-Ho; Chen, Yu-Bin; Chang, Shu-Jing; Ke, Tung-Ting; Cheng, Hung-Chi; Wu, Hua-Lin
2015-03-01
Metastasis is responsible for 90% of all cancer-related deaths in humans. As a result, reliable techniques for detecting metastatic cells are urgently required. Although various techniques have been proposed for metastasis detection, they are generally capable of detecting metastatic cells only once migration has already occurred. Accordingly, the present study proposes an optical method for physical characterization of metastatic cancer cells using a scanned laser pico-projection system (SLPP). The validity of the proposed method is demonstrated using five pairs of cancer cell lines and two pairs of non-cancer cell lines treated by IPTG induction in order to mimic normal cells with an overexpression of oncogene. The results show that for all of the considered cell lines, the SLPP speckle contrast of the high-metastatic cells is significantly higher than that of the low-metastatic cells. As a result, the speckle contrast measurement provides a reliable means of distinguishing quantitatively between low- and high-metastatic cells of the same origin. Compared to existing metastasis detection methods, the proposed SLPP approach has many advantages, including a higher throughput, a lower cost, a larger sample size and a more reliable diagnostic performance. As a result, it provides a highly promising solution for physical characterization of metastatic cancer cells in vitro.
Reliability Evaluation of Machine Center Components Based on Cascading Failure Analysis
NASA Astrophysics Data System (ADS)
Zhang, Ying-Zhi; Liu, Jin-Tong; Shen, Gui-Xiang; Long, Zhe; Sun, Shu-Guang
2017-07-01
In order to rectify the problems that the component reliability model exhibits deviation, and the evaluation result is low due to the overlook of failure propagation in traditional reliability evaluation of machine center components, a new reliability evaluation method based on cascading failure analysis and the failure influenced degree assessment is proposed. A direct graph model of cascading failure among components is established according to cascading failure mechanism analysis and graph theory. The failure influenced degrees of the system components are assessed by the adjacency matrix and its transposition, combined with the Pagerank algorithm. Based on the comprehensive failure probability function and total probability formula, the inherent failure probability function is determined to realize the reliability evaluation of the system components. Finally, the method is applied to a machine center, it shows the following: 1) The reliability evaluation values of the proposed method are at least 2.5% higher than those of the traditional method; 2) The difference between the comprehensive and inherent reliability of the system component presents a positive correlation with the failure influenced degree of the system component, which provides a theoretical basis for reliability allocation of machine center system.
Sunspot Positions and Areas from Observations by Galileo Galilei
NASA Astrophysics Data System (ADS)
Vokhmyanin, M. V.; Zolotova, N. V.
2018-02-01
Sunspot records in the seventeenth century provide important information on the solar activity before the Maunder minimum, yielding reliable sunspot indices and the solar butterfly diagram. Galilei's letters to Cardinal Francesco Barberini and Marcus Welser contain daily solar observations on 3 - 11 May, 2 June - 8 July, and 19 - 21 August 1612. These historical archives do not provide the time of observation, which results in uncertainty in the sunspot coordinates. To obtain them, we present a method that minimizes the discrepancy between the sunspot latitudes. We provide areas and heliographic coordinates of 82 sunspot groups. In contrast to Sheiner's butterfly diagram, we found only one sunspot group near the Equator. This provides a higher reliability of Galilei's drawings. Large sunspot groups are found to emerge at the same longitude in the northern hemisphere from 3 May to 21 August, which indicates an active longitude.
"Fly-by-Wireless" and Wireless Sensors Update
NASA Technical Reports Server (NTRS)
Studor, George F.
2009-01-01
This slide presentation reviews the uses of wires in the Aerospace industry. The vision is to minimize cables and connectors and increase functionality across the aerospace industry by providing reliable lower cost modular and higher performance alternatives to wired data connectivity to benefit the entire vehicle and program
Using Rasch Analysis to Inform Rating Scale Development
ERIC Educational Resources Information Center
Van Zile-Tamsen, Carol
2017-01-01
The use of surveys, questionnaires, and rating scales to measure important outcomes in higher education is pervasive, but reliability and validity information is often based on problematic Classical Test Theory approaches. Rasch Analysis, based on Item Response Theory, provides a better alternative for examining the psychometric quality of rating…
Applying Learning Theories and Instructional Design Models for Effective Instruction
ERIC Educational Resources Information Center
Khalil, Mohammed K.; Elkhider, Ihsan A.
2016-01-01
Faculty members in higher education are involved in many instructional design activities without formal training in learning theories and the science of instruction. Learning theories provide the foundation for the selection of instructional strategies and allow for reliable prediction of their effectiveness. To achieve effective learning…
Bian, Lin
2012-01-01
In clinical practice, hearing thresholds are measured at only five to six frequencies at octave intervals. Thus, the audiometric configuration cannot closely reflect the actual status of the auditory structures. In addition, differential diagnosis requires quantitative comparison of behavioral thresholds with physiological measures, such as otoacoustic emissions (OAEs) that are usually measured in higher resolution. The purpose of this research was to develop a method to improve the frequency resolution of the audiogram. A repeated-measure design was used in the study to evaluate the reliability of the threshold measurements. A total of 16 participants with clinically normal hearing and mild hearing loss were recruited from a population of university students. No intervention was involved in the study. Custom developed system and software were used for threshold acquisition with quality control (QC). With real-ear calibration and monitoring of test signals, the system provided accurate and individualized measure of hearing thresholds that were determined by an analysis based on signal detection theory (SDT). The reliability of the threshold measure was assessed by correlation and differences between the repeated measures. The audiometric configurations were diverse and unique to each individual ear. The accuracy, within-subject reliability, and between-test repeatability are relatively high. With QC, the high-resolution audiograms can be reliably and accurately measured. Hearing thresholds measured as ear canal sound pressures with higher frequency resolution can provide more customized hearing-aid fitting. The test system may be integrated with other physiological measures, such as OAEs, into a comprehensive evaluative tool. American Academy of Audiology.
Coolidge, Trilby; Hillstead, M Blake; Farjo, Nadia; Weinstein, Philip; Coldwell, Susan E
2010-05-13
Hispanics comprise the largest ethnic minority group in the United States. Previous work with the Spanish Modified Dental Anxiety Scale (MDAS) yielded good validity, but lower test-retest reliability. We report the performance of the Spanish MDAS in a new sample, as well as the performance of the Spanish Revised Dental Beliefs Survey (R-DBS). One hundred sixty two Spanish-speaking adults attending Spanish-language church services or an Hispanic cultural festival completed questionnaires containing the Spanish MDAS, Spanish R-DBS, and dental attendance questions, and underwent a brief oral examination. Church attendees completed the questionnaire a second time, for test-retest purposes. The Spanish MDAS and R-DBS were completed by 156 and 136 adults, respectively. The test-retest reliability of the Spanish MDAS was 0.83 (95% CI = 0.60-0.92). The internal reliability of the Spanish R-DBS was 0.96 (95% CI = 0.94-0.97), and the test-retest reliability was 0.86 (95% CI = 0.64-0.94). The two measures were significantly correlated (Spearman's rho = 0.38, p < 0.001). Participants who do not currently go to a dentist had significantly higher MDAS scores (t = 3.40, df = 106, p = 0.003) as well as significantly higher R-DBS scores (t = 2.21, df = 131, p = 0.029). Participants whose most recent dental visit was for pain or a problem, rather than for a check-up, scored significantly higher on both the MDAS (t = 3.00, df = 106, p = 0.003) and the R-DBS (t = 2.85, df = 92, p = 0.005). Those with high dental fear (MDAS score 19 or greater) were significantly more likely to have severe caries (Chi square = 6.644, df = 2, p = 0.036). Higher scores on the R-DBS were significantly related to having more missing teeth (Spearman's rho = 0.23, p = 0.009). In this sample, the test-retest reliability of the Spanish MDAS was higher. The significant relationships between dental attendance and questionnaire scores, as well as the difference in caries severity seen in those with high fear, add to the evidence of this scale's construct validity in Hispanic samples. Our results also provide evidence for the internal and test-retest reliabilities, as well as the construct validity, of the Spanish R-DBS.
Design and Analysis of a Flexible, Reliable Deep Space Life Support System
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2012-01-01
This report describes a flexible, reliable, deep space life support system design approach that uses either storage or recycling or both together. The design goal is to provide the needed life support performance with the required ultra reliability for the minimum Equivalent System Mass (ESM). Recycling life support systems used with multiple redundancy can have sufficient reliability for deep space missions but they usually do not save mass compared to mixed storage and recycling systems. The best deep space life support system design uses water recycling with sufficient water storage to prevent loss of crew if recycling fails. Since the amount of water needed for crew survival is a small part of the total water requirement, the required amount of stored water is significantly less than the total to be consumed. Water recycling with water, oxygen, and carbon dioxide removal material storage can achieve the high reliability of full storage systems with only half the mass of full storage and with less mass than the highly redundant recycling systems needed to achieve acceptable reliability. Improved recycling systems with lower mass and higher reliability could perform better than systems using storage.
Smith, Justin D; Dishion, Thomas J; Brown, Kimbree; Ramos, Karina; Knoble, Naomi B; Shaw, Daniel S; Wilson, Melvin N
2016-01-01
The valid and reliable assessment of fidelity is critical at all stages of intervention research and is particularly germane to interpreting the results of efficacy and implementation trials. Ratings of protocol adherence typically are reliable, but ratings of therapist competence are plagued by low reliability. Because family context and case conceptualization guide the therapist's delivery of interventions, the reliability of fidelity ratings might be improved if the coder is privy to client context in the form of an ecological assessment. We conducted a randomized experiment to test this hypothesis. A subsample of 46 families with 5-year-old children from a multisite randomized trial who participated in the feedback session of the Family Check-Up (FCU) intervention were selected. We randomly assigned FCU feedback sessions to be rated for fidelity to the protocol using the COACH rating system either after the coder reviewed the results of a recent ecological assessment or had not. Inter-rater reliability estimates of fidelity ratings were meaningfully higher for the assessment information condition compared to the no-information condition. Importantly, the reliability of the COACH mean score was found to be statistically significantly higher in the information condition. These findings suggest that the reliability of observational ratings of fidelity, particularly when the competence or quality of delivery is considered, could be improved by providing assessment data to the coders. Our findings might be most applicable to assessment-driven interventions, where assessment data explicitly guides therapist's selection of intervention strategies tailored to the family's context and needs, but they could also apply to other intervention programs and observational coding of context-dependent therapy processes, such as the working alliance.
Smith, Justin D.; Dishion, Thomas J.; Brown, Kimbree; Ramos, Karina; Knoble, Naomi B.; Shaw, Daniel S.; Wilson, Melvin N.
2015-01-01
The valid and reliable assessment of fidelity is critical at all stages of intervention research and is particularly germane to interpreting the results of efficacy and implementation trials. Ratings of protocol adherence typically are reliable, but ratings of therapist competence are plagued by low reliability. Because family context and case conceptualization guide the therapist's delivery of interventions, the reliability of fidelity ratings might be improved if the coder is privy to client context in the form of an ecological assessment. We conducted a randomized experiment to test this hypothesis. A subsample of 46 families with 5-year-old children from a multisite randomized trial who participated in the feedback session of the Family Check-Up (FCU) intervention were selected. We randomly assigned FCU feedback sessions to be rated for fidelity to the protocol using the COACH rating system either after the coder reviewed the results of a recent ecological assessment or had not. Inter-rater reliability estimates of fidelity ratings were meaningfully higher for the assessment information condition compared to the no-information condition. Importantly, the reliability of the COACH mean score was found to be statistically significantly higher in the information condition. These findings suggest that the reliability of observational ratings of fidelity, particularly when the competence or quality of delivery is considered, could be improved by providing assessment data to the coders. Our findings might be most applicable to assessment-driven interventions, where assessment data explicitly guides therapist's selection of intervention strategies tailored to the family's context and needs, but they could also apply to other intervention programs and observational coding of context-dependent therapy processes, such as the working alliance. PMID:26271300
NASA Technical Reports Server (NTRS)
Sargusingh, Miriam J.; Nelson, Jason R.
2014-01-01
NASA has highlighted reliability as critical to future human space exploration, particularly in the area of environmental controls and life support systems. The Advanced Exploration Systems (AES) projects have been encouraged to pursue higher reliability components and systems as part of technology development plans. However, no consensus has been reached on what is meant by improving on reliability, or on how to assess reliability within the AES projects. This became apparent when trying to assess reliability as one of several figures of merit for a regenerable water architecture trade study. In the spring of 2013, the AES Water Recovery Project hosted a series of events at Johnson Space Center with the intended goal of establishing a common language and understanding of NASA's reliability goals, and equipping the projects with acceptable means of assessing the respective systems. This campaign included an educational series in which experts from across the agency and academia provided information on terminology, tools, and techniques associated with evaluating and designing for system reliability. The campaign culminated in a workshop that included members of the Environmental Control and Life Support System and AES communities. The goal of this workshop was to develop a consensus on what reliability means to AES and identify methods for assessing low- to mid-technology readiness level technologies for reliability. This paper details the results of that workshop.
ECLSS Reliability for Long Duration Missions Beyond Lower Earth Orbit
NASA Technical Reports Server (NTRS)
Sargusingh, Miriam J.; Nelson, Jason
2014-01-01
Reliability has been highlighted by NASA as critical to future human space exploration particularly in the area of environmental controls and life support systems. The Advanced Exploration Systems (AES) projects have been encouraged to pursue higher reliability components and systems as part of technology development plans. However there is no consensus on what is meant by improving on reliability; nor on how to assess reliability within the AES projects. This became apparent when trying to assess reliability as one of several figures of merit for a regenerable water architecture trade study. In the spring of 2013, the AES Water Recovery Project (WRP) hosted a series of events at the NASA Johnson Space Center (JSC) with the intended goal of establishing a common language and understanding of our reliability goals, and equipping the projects with acceptable means of assessing our respective systems. This campaign included an educational series in which experts from across the agency and academia provided information on terminology, tools and techniques associated with evalauating and designing for system reliability. The campaign culminated in a workshop at JSC with members of the ECLSS and AES communities with the goal of developing a consensus on what reliability means to AES and identifying methods for assessing our low to mid-technology readiness level (TRL) technologies for reliability. This paper details the results of the workshop.
ECLSS Reliability for Long Duration Missions Beyond Lower Earth Orbit
NASA Technical Reports Server (NTRS)
Sargusingh, Miriam J.; Nelson, Jason
2014-01-01
Reliability has been highlighted by NASA as critical to future human space exploration particularly in the area of environmental controls and life support systems. The Advanced Exploration Systems (AES) projects have been encouraged to pursue higher reliability components and systems as part of technology development plans. However, there is no consensus on what is meant by improving on reliability; nor on how to assess reliability within the AES projects. This became apparent when trying to assess reliability as one of several figures of merit for a regenerable water architecture trade study. In the Spring of 2013, the AES Water Recovery Project (WRP) hosted a series of events at the NASA Johnson Space Center (JSC) with the intended goal of establishing a common language and understanding of our reliability goals and equipping the projects with acceptable means of assessing our respective systems. This campaign included an educational series in which experts from across the agency and academia provided information on terminology, tools and techniques associated with evaluating and designing for system reliability. The campaign culminated in a workshop at JSC with members of the ECLSS and AES communities with the goal of developing a consensus on what reliability means to AES and identifying methods for assessing our low to mid-technology readiness level (TRL) technologies for reliability. This paper details the results of the workshop.
Enhancing recovery rates: lessons from year one of IAPT.
Gyani, Alex; Shafran, Roz; Layard, Richard; Clark, David M
2013-09-01
The English Improving Access to Psychological Therapies (IAPT) initiative aims to make evidence-based psychological therapies for depression and anxiety disorder more widely available in the National Health Service (NHS). 32 IAPT services based on a stepped care model were established in the first year of the programme. We report on the reliable recovery rates achieved by patients treated in the services and identify predictors of recovery at patient level, service level, and as a function of compliance with National Institute of Health and Care Excellence (NICE) Treatment Guidelines. Data from 19,395 patients who were clinical cases at intake, attended at least two sessions, had at least two outcomes scores and had completed their treatment during the period were analysed. Outcome was assessed with the patient health questionnaire depression scale (PHQ-9) and the anxiety scale (GAD-7). Data completeness was high for a routine cohort study. Over 91% of treated patients had paired (pre-post) outcome scores. Overall, 40.3% of patients were reliably recovered at post-treatment, 63.7% showed reliable improvement and 6.6% showed reliable deterioration. Most patients received treatments that were recommended by NICE. When a treatment not recommended by NICE was provided, recovery rates were reduced. Service characteristics that predicted higher reliable recovery rates were: high average number of therapy sessions; higher step-up rates among individuals who started with low intensity treatment; larger services; and a larger proportion of experienced staff. Compliance with the IAPT clinical model is associated with enhanced rates of reliable recovery. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.
Characterizing wind power resource reliability in southern Africa
Fant, Charles; Gunturu, Bhaskar; Schlosser, Adam
2015-08-29
Producing electricity from wind is attractive because it provides a clean, low-maintenance power supply. However, wind resource is intermittent on various timescales, thus occasionally introducing large and sudden changes in power supply. A better understanding of this variability can greatly benefit power grid planning. In the following study, wind resource is characterized using metrics that highlight these intermittency issues; therefore identifying areas of high and low wind power reliability in southern Africa and Kenya at different time-scales. After developing a wind speed profile, these metrics are applied at various heights in order to assess the added benefit of raising themore » wind turbine hub. Furthermore, since the interconnection of wind farms can aid in reducing the overall intermittency, the value of interconnecting near-by sites is mapped using two distinct methods. Of the countries in this region, the Republic of South Africa has shown the most interest in wind power investment. For this reason, we focus parts of the study on wind reliability in the country. The study finds that, although mean Wind Power Density is high in South Africa compared to its neighboring countries, wind power resource tends to be less reliable than in other parts of southern Africa—namely central Tanzania. We also find that South Africa’s potential varies over different timescales, with higher reliability in the summer than winter, and higher reliability during the day than at night. This study is concluded by introducing two methods and measures to characterize the value of interconnection, including the use of principal component analysis to identify areas with a common signal.« less
Characterizing wind power resource reliability in southern Africa
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fant, Charles; Gunturu, Bhaskar; Schlosser, Adam
Producing electricity from wind is attractive because it provides a clean, low-maintenance power supply. However, wind resource is intermittent on various timescales, thus occasionally introducing large and sudden changes in power supply. A better understanding of this variability can greatly benefit power grid planning. In the following study, wind resource is characterized using metrics that highlight these intermittency issues; therefore identifying areas of high and low wind power reliability in southern Africa and Kenya at different time-scales. After developing a wind speed profile, these metrics are applied at various heights in order to assess the added benefit of raising themore » wind turbine hub. Furthermore, since the interconnection of wind farms can aid in reducing the overall intermittency, the value of interconnecting near-by sites is mapped using two distinct methods. Of the countries in this region, the Republic of South Africa has shown the most interest in wind power investment. For this reason, we focus parts of the study on wind reliability in the country. The study finds that, although mean Wind Power Density is high in South Africa compared to its neighboring countries, wind power resource tends to be less reliable than in other parts of southern Africa—namely central Tanzania. We also find that South Africa’s potential varies over different timescales, with higher reliability in the summer than winter, and higher reliability during the day than at night. This study is concluded by introducing two methods and measures to characterize the value of interconnection, including the use of principal component analysis to identify areas with a common signal.« less
2011-01-01
Background Since stress is hypothesized to play a role in the etiology of obesity during adolescence, research on associations between adolescent stress and obesity-related parameters and behaviours is essential. Due to lack of a well-established recent stress checklist for use in European adolescents, the study investigated the reliability and validity of the Adolescent Stress Questionnaire (ASQ) for assessing perceived stress in European adolescents. Methods The ASQ was translated into the languages of the participating cities (Ghent, Stockholm, Vienna, Zaragoza, Pecs and Athens) and was implemented within the HELENA cross-sectional study. A total of 1140 European adolescents provided a valid ASQ, comprising 10 component scales, used for internal reliability (Cronbach α) and construct validity (confirmatory factor analysis or CFA). Contributions of socio-demographic (gender, age, pubertal stage, socio-economic status) characteristics to the ASQ score variances were investigated. Two-hundred adolescents also provided valid saliva samples for cortisol analysis to compare with the ASQ scores (criterion validity). Test-retest reliability was investigated using two ASQ assessments from 37 adolescents. Results Cronbach α-values of the ASQ scales (0.57 to 0.88) demonstrated a moderate internal reliability of the ASQ, and intraclass correlation coefficients (0.45 to 0.84) established an insufficient test-retest reliability of the ASQ. The adolescents' gender (girls had higher stress scores than boys) and pubertal stage (those in a post-pubertal development had higher stress scores than others) significantly contributed to the variance in ASQ scores, while their age and socio-economic status did not. CFA results showed that the original scale construct fitted moderately with the data in our European adolescent population. Only in boys, four out of 10 ASQ scale scores were a significant positive predictor for baseline wake-up salivary cortisol, suggesting a rather poor criterion validity of the ASQ, especially in girls. Conclusions In our European adolescent sample, the ASQ had an acceptable internal reliability and construct validity and the adolescents' gender and pubertal stage systematically contributed to the ASQ variance, but its test-retest reliability and criterion validity were rather poor. Overall, the utility of the ASQ for assessing perceived stress in adolescents across Europe is uncertain and some aspects require further examination. PMID:21943341
Mother-child bonding assessment tools☆
Perrelli, Jaqueline Galdino Albuquerque; Zambaldi, Carla Fonseca; Cantilino, Amaury; Sougey, Everton Botelho
2014-01-01
Objective: To identify and describe research tools used to evaluate bonding between mother and child up to one year of age, as well as to provide information on reliability and validity measures related to these tools. Data source: Research studies available on PUBMED, LILACS, ScienceDirect, PsycINFO and CINAHL databases with the following descriptors: mother-child relations and mother infant relationship, as well as the expressions validity, reliability and scale. Data synthesis: 23 research studies were selected and fully analyzed. Thirteen evaluation research tools were identified concerning mother and child attachment: seven scales, three questionnaires, two inventories and one observation method. From all tools analyzed, the Prenatal Attachment Inventory presented the higher validity and reliability measures to assess mother and fetus relation during pregnancy. Concerning the puerperal period, better consistency coefficients were found for Maternal Attachment Inventory and Postpartum Bonding Questionnaire. Besides, the last one revealed a higher sensibility to identify amenable and severe disorders in the affective relations between mother and child. Conclusions: The majority of research tools are reliable to study the phenomenon presented, although there are some limitations regarding the construct and criterion related to validity. In addition to this, only two of them are translated into Portuguese and adapted to women and children populations in Brazil, being a decisive gap to scientific production in this area. PMID:25479859
WEAMR — A Weighted Energy Aware Multipath Reliable Routing Mechanism for Hotline-Based WSNs
Tufail, Ali; Qamar, Arslan; Khan, Adil Mehmood; Baig, Waleed Akram; Kim, Ki-Hyung
2013-01-01
Reliable source to sink communication is the most important factor for an efficient routing protocol especially in domains of military, healthcare and disaster recovery applications. We present weighted energy aware multipath reliable routing (WEAMR), a novel energy aware multipath routing protocol which utilizes hotline-assisted routing to meet such requirements for mission critical applications. The protocol reduces the number of average hops from source to destination and provides unmatched reliability as compared to well known reactive ad hoc protocols i.e., AODV and AOMDV. Our protocol makes efficient use of network paths based on weighted cost calculation and intelligently selects the best possible paths for data transmissions. The path cost calculation considers end to end number of hops, latency and minimum energy node value in the path. In case of path failure path recalculation is done efficiently with minimum latency and control packets overhead. Our evaluation shows that our proposal provides better end-to-end delivery with less routing overhead and higher packet delivery success ratio compared to AODV and AOMDV. The use of multipath also increases overall life time of WSN network using optimum energy available paths between sender and receiver in WDNs. PMID:23669714
WEAMR-a weighted energy aware multipath reliable routing mechanism for hotline-based WSNs.
Tufail, Ali; Qamar, Arslan; Khan, Adil Mehmood; Baig, Waleed Akram; Kim, Ki-Hyung
2013-05-13
Reliable source to sink communication is the most important factor for an efficient routing protocol especially in domains of military, healthcare and disaster recovery applications. We present weighted energy aware multipath reliable routing (WEAMR), a novel energy aware multipath routing protocol which utilizes hotline-assisted routing to meet such requirements for mission critical applications. The protocol reduces the number of average hops from source to destination and provides unmatched reliability as compared to well known reactive ad hoc protocols i.e., AODV and AOMDV. Our protocol makes efficient use of network paths based on weighted cost calculation and intelligently selects the best possible paths for data transmissions. The path cost calculation considers end to end number of hops, latency and minimum energy node value in the path. In case of path failure path recalculation is done efficiently with minimum latency and control packets overhead. Our evaluation shows that our proposal provides better end-to-end delivery with less routing overhead and higher packet delivery success ratio compared to AODV and AOMDV. The use of multipath also increases overall life time of WSN network using optimum energy available paths between sender and receiver in WDNs.
Implications of scaling on static RAM bit cell stability and reliability
NASA Astrophysics Data System (ADS)
Coones, Mary Ann; Herr, Norm; Bormann, Al; Erington, Kent; Soorholtz, Vince; Sweeney, John; Phillips, Michael
1993-01-01
In order to lower manufacturing costs and increase performance, static random access memory (SRAM) bit cells are scaled progressively toward submicron geometries. The reliability of an SRAM is highly dependent on the bit cell stability. Smaller memory cells with less capacitance and restoring current make the array more susceptible to failures from defectivity, alpha hits, and other instabilities and leakage mechanisms. Improving long term reliability while migrating to higher density devices makes the task of building in and improving reliability increasingly difficult. Reliability requirements for high density SRAMs are very demanding with failure rates of less than 100 failures per billion device hours (100 FITs) being a common criteria. Design techniques for increasing bit cell stability and manufacturability must be implemented in order to build in this level of reliability. Several types of analyses are performed to benchmark the performance of the SRAM device. Examples of these analysis techniques which are presented here include DC parametric measurements of test structures, functional bit mapping of the circuit used to characterize the entire distribution of bits, electrical microprobing of weak and/or failing bits, and system and accelerated soft error rate measurements. These tests allow process and design improvements to be evaluated prior to implementation on the final product. These results are used to provide comprehensive bit cell characterization which can then be compared to device models and adjusted accordingly to provide optimized cell stability versus cell size for a particular technology. The result is designed in reliability which can be accomplished during the early stages of product development.
Measuring family-centred practices of professionals in early intervention services in Taiwan.
Kang, L-J; Palisano, R J; Simeonsson, R J; Hwang, A-W
2017-09-01
Family-centred practices emphasize professional supports for forming partnerships with families in early intervention. The Measure of Processes of Care for Service Providers (MPOC-SP) measures the perceptions of paediatric service providers in supporting children and families. This study aimed to establish reliability of the Chinese version of the MPOC-SP (C-MPOC-SP) and to examine professional perceptions of family-centred practices in relation to professional discipline and years of experience. A convenience sample of 94 physical therapists, occupational therapists, speech-language pathologists, social workers and early childhood educators completed the C-MPOC-SP. Thirty-seven professionals completed the measure a second time within 2-4 weeks for test-retest reliability. Internal consistency and test-retest reliability were examined by Cronbach's α and intra-class correlation coefficient. Comparisons were made across professional disciplines by multivariate analyses of variance followed by analyses of variance. Relationships between years of experience and ratings of family-centred practices were examined by Pearson's correlation coefficients (r). Cronbach's α for items on each of the four scales of the C-MPOC-SP ranged from 0.80 to 0.92, indicating adequate internal consistency. Intra-class correlation coefficient between the initial and repeat completion of the C-MPOC-SP for each scale ranged from 0.56 to 0.77, indicating adequate to excellent test-retest reliability. Mean ratings for the Communicating Specific Information were significantly higher for physical therapists, occupational therapists and speech-language pathologists than for social workers (P = 0.001). The C-MPOC-SP scores were positively correlated with years of experience for all four scales (r = 0.23-0.38; P < 0.05). This study established adequate internal consistency and adequate to excellent test-retest reliability of the C-MPOC-SP in measuring perceptions of family centeredness of early intervention service providers. Cross-discipline differences were found in communicating specific information about the child. Higher perceptions of family centeredness were associated with more years of experience. The results support the utility of the C-MPOC-SP in professional education and programme evaluation of early intervention services in Taiwan. © 2017 John Wiley & Sons Ltd.
Self-Alining End Supports for Energy Absorber
NASA Technical Reports Server (NTRS)
Alfaro-Bou, E.; Eichelberger, C. P.; Fasanella, E.
1986-01-01
Simple devices stabilize axially-loaded compressive members. Energyabsorbing column held by two end supports, which stabilize column and tolerate misalinement. Column absorbs excess load by collapsing lengthwise. Self-alining supports small, lightweight, and almost maintenance-free. Their use eliminates alinement problem, opening up more applications and providing higher reliability for compressively-loaded energy absorbers.
Evaluating the Use of Criteria for Assessing Profession-Specific Communication Skills in Pharmacy
ERIC Educational Resources Information Center
Hyvarinen, Marja-Leena; Tanskanen, Paavo; Katajavuori, Nina; Isotalus, Pekka
2012-01-01
One central task in higher education is to provide students with interpersonal communication competence in their profession. To achieve this, specialised training, based on an understanding of disciplinary communication practices and appropriate assessment methods, is needed. However, there is a lack of reliable assessment instruments which are…
Ferris, M; Cohen, S; Haberman, C; Javalkar, K; Massengill, S; Mahan, J D; Kim, S; Bickford, K; Cantu, G; Medeiros, M; Phillips, A; Ferris, M T; Hooper, S R
2015-01-01
The Self-Management and Transition to Adulthood with Rx=Treatment (STARx) Questionnaire was developed to collect information on self-management and health care transition (HCT) skills, via self-report, in a broad population of adolescents and young adults (AYAs) with chronic conditions. Over several iterations, the STARx questionnaire was created with AYA, family, and health provider input. The development and pilot testing of the STARx Questionnaire took place with the assistance of 1219 AYAs with different chronic health conditions, in multiple institutions and settings over three phases: item development, pilot testing, reliability and factor structuring. The three development phases resulted in a final version of the STARx Questionnaire. The exploratory factor analysis of the third version of the 18-item STARx identified six factors that accounted for about 65% of the variance: Medication management, Provider communication, Engagement during appointments, Disease knowledge, Adult health responsibilities, and Resource utilization. Reliability estimates revealed good internal consistency and temporal stability, with the alpha coefficient for the overall scale being .80. The STARx was developmentally sensitive, with older patients scoring significantly higher on nearly every factor than younger patients. The STARx Questionnaire is a reliable, self-report tool with adequate internal consistency, temporal stability, and a strong, multidimensional factor structure. It provides another assessment strategy to measure self-management and transition skills in AYAs with chronic conditions. Copyright © 2015 Elsevier Inc. All rights reserved.
Using meta-quality to assess the utility of volunteered geographic information for science.
Langley, Shaun A; Messina, Joseph P; Moore, Nathan
2017-11-06
Volunteered geographic information (VGI) has strong potential to be increasingly valuable to scientists in collaboration with non-scientists. The abundance of mobile phones and other wireless forms of communication open up significant opportunities for the public to get involved in scientific research. As these devices and activities become more abundant, questions of uncertainty and error in volunteer data are emerging as critical components for using volunteer-sourced spatial data. Here we present a methodology for using VGI and assessing its sensitivity to three types of error. More specifically, this study evaluates the reliability of data from volunteers based on their historical patterns. The specific context is a case study in surveillance of tsetse flies, a health concern for being the primary vector of African Trypanosomiasis. Reliability, as measured by a reputation score, determines the threshold for accepting the volunteered data for inclusion in a tsetse presence/absence model. Higher reputation scores are successful in identifying areas of higher modeled tsetse prevalence. A dynamic threshold is needed but the quality of VGI will improve as more data are collected and the errors in identifying reliable participants will decrease. This system allows for two-way communication between researchers and the public, and a way to evaluate the reliability of VGI. Boosting the public's ability to participate in such work can improve disease surveillance and promote citizen science. In the absence of active surveillance, VGI can provide valuable spatial information given that the data are reliable.
The reliability of the Glasgow Coma Scale: a systematic review.
Reith, Florence C M; Van den Brande, Ruben; Synnot, Anneliese; Gruen, Russell; Maas, Andrew I R
2016-01-01
The Glasgow Coma Scale (GCS) provides a structured method for assessment of the level of consciousness. Its derived sum score is applied in research and adopted in intensive care unit scoring systems. Controversy exists on the reliability of the GCS. The aim of this systematic review was to summarize evidence on the reliability of the GCS. A literature search was undertaken in MEDLINE, EMBASE and CINAHL. Observational studies that assessed the reliability of the GCS, expressed by a statistical measure, were included. Methodological quality was evaluated with the consensus-based standards for the selection of health measurement instruments checklist and its influence on results considered. Reliability estimates were synthesized narratively. We identified 52 relevant studies that showed significant heterogeneity in the type of reliability estimates used, patients studied, setting and characteristics of observers. Methodological quality was good (n = 7), fair (n = 18) or poor (n = 27). In good quality studies, kappa values were ≥0.6 in 85%, and all intraclass correlation coefficients indicated excellent reliability. Poor quality studies showed lower reliability estimates. Reliability for the GCS components was higher than for the sum score. Factors that may influence reliability include education and training, the level of consciousness and type of stimuli used. Only 13% of studies were of good quality and inconsistency in reported reliability estimates was found. Although the reliability was adequate in good quality studies, further improvement is desirable. From a methodological perspective, the quality of reliability studies needs to be improved. From a clinical perspective, a renewed focus on training/education and standardization of assessment is required.
Developing an Advanced Life Support System for the Flexible Path into Deep Space
NASA Technical Reports Server (NTRS)
Jones, Harry W.; Kliss, Mark H.
2010-01-01
Long duration human missions beyond low Earth orbit, such as a permanent lunar base, an asteroid rendezvous, or exploring Mars, will use recycling life support systems to preclude supplying large amounts of metabolic consumables. The International Space Station (ISS) life support design provides a historic guiding basis for future systems, but both its system architecture and the subsystem technologies should be reconsidered. Different technologies for the functional subsystems have been investigated and some past alternates appear better for flexible path destinations beyond low Earth orbit. There is a need to develop more capable technologies that provide lower mass, increased closure, and higher reliability. A major objective of redesigning the life support system for the flexible path is achieving the maintainability and ultra-reliability necessary for deep space operations.
Intersession reliability of self-selected and narrow stance balance testing in older adults.
Riemann, Bryan L; Piersol, Kelsey
2017-10-01
Despite the common practice of using force platforms to assess balance of older adults, few investigations have examined the reliability of postural screening tests in this population. We sought to determine the test-retest reliability of self-selected and narrow stance balance testing with eyes open and eyes closed in healthy older adults. Thirty older adults (>65 years) completed 45 s trials of eyes open and eyes closed stability tests using self-selected and narrow stances on two separate days (1.9 ± .7 days). Average medial-lateral center of pressure velocity was computed. The ICC results ranged from .74 to .86, and no significant systematic changes (P < .05) occurred between the testing sessions for any of the tests. The standard error of measurement ranged from 15.9 to 23.6%. Reliability estimates were similar between the two stances and visual conditions assessed. Slightly higher coefficients were identified for the self-selected stances compared to the narrow stances under both visual conditions; however, there were negligible differences between the sessions. The within subject session-to-session variability provides a basis for further research to consider differences between fallers and non-fallers. Reliability for eyes open and closed balance testing using self-selected and narrow stances in older adults was established which should provide a foundation for the development of fall risk screening tests.
Test-Retest Reliability of Graph Metrics in Functional Brain Networks: A Resting-State fNIRS Study
Niu, Haijing; Li, Zhen; Liao, Xuhong; Wang, Jinhui; Zhao, Tengda; Shu, Ni; Zhao, Xiaohu; He, Yong
2013-01-01
Recent research has demonstrated the feasibility of combining functional near-infrared spectroscopy (fNIRS) and graph theory approaches to explore the topological attributes of human brain networks. However, the test-retest (TRT) reliability of the application of graph metrics to these networks remains to be elucidated. Here, we used resting-state fNIRS and a graph-theoretical approach to systematically address TRT reliability as it applies to various features of human brain networks, including functional connectivity, global network metrics and regional nodal centrality metrics. Eighteen subjects participated in two resting-state fNIRS scan sessions held ∼20 min apart. Functional brain networks were constructed for each subject by computing temporal correlations on three types of hemoglobin concentration information (HbO, HbR, and HbT). This was followed by a graph-theoretical analysis, and then an intraclass correlation coefficient (ICC) was further applied to quantify the TRT reliability of each network metric. We observed that a large proportion of resting-state functional connections (∼90%) exhibited good reliability (0.6< ICC <0.74). For global and nodal measures, reliability was generally threshold-sensitive and varied among both network metrics and hemoglobin concentration signals. Specifically, the majority of global metrics exhibited fair to excellent reliability, with notably higher ICC values for the clustering coefficient (HbO: 0.76; HbR: 0.78; HbT: 0.53) and global efficiency (HbO: 0.76; HbR: 0.70; HbT: 0.78). Similarly, both nodal degree and efficiency measures also showed fair to excellent reliability across nodes (degree: 0.52∼0.84; efficiency: 0.50∼0.84); reliability was concordant across HbO, HbR and HbT and was significantly higher than that of nodal betweenness (0.28∼0.68). Together, our results suggest that most graph-theoretical network metrics derived from fNIRS are TRT reliable and can be used effectively for brain network research. This study also provides important guidance on the choice of network metrics of interest for future applied research in developmental and clinical neuroscience. PMID:24039763
Baylis, Adriane; Chapman, Kathy; Whitehill, Tara L; Group, The Americleft Speech
2015-11-01
To investigate the validity and reliability of multiple listener judgments of hypernasality and audible nasal emission, in children with repaired cleft palate, using visual analog scaling (VAS) and equal-appearing interval (EAI) scaling. Prospective comparative study of multiple listener ratings of hypernasality and audible nasal emission. Multisite institutional. Five trained and experienced speech-language pathologist listeners from the Americleft Speech Project. Average VAS and EAI ratings of hypernasality and audible nasal emission/turbulence for 12 video-recorded speech samples from the Americleft Speech Project. Intrarater and interrater reliability was computed, as well as linear and polynomial models of best fit. Intrarater and interrater reliability was acceptable for both rating methods; however, reliability was higher for VAS as compared to EAI ratings. When VAS ratings were plotted against EAI ratings, results revealed a stronger curvilinear relationship. The results of this study provide additional evidence that alternate rating methods such as VAS may offer improved validity and reliability over EAI ratings of speech. VAS should be considered a viable method for rating hypernasality and nasal emission in speech in children with repaired cleft palate.
ERIC Educational Resources Information Center
Yao, Lihua
2012-01-01
Multidimensional computer adaptive testing (MCAT) can provide higher precision and reliability or reduce test length when compared with unidimensional CAT or with the paper-and-pencil test. This study compared five item selection procedures in the MCAT framework for both domain scores and overall scores through simulation by varying the structure…
Development of a short version of the new brief job stress questionnaire.
Inoue, Akiomi; Kawakami, Norito; Shimomitsu, Teruichi; Tsutsumi, Akizumi; Haratani, Takashi; Yoshikawa, Toru; Shimazu, Akihito; Odagiri, Yuko
2014-01-01
This study was aimed to investigate the test-retest reliability and validity of a short version of the New Brief Job Stress Questionnaire (New BJSQ) whose scales have one item selected from a standard version. Based on the results from an anonymous web-based questionnaire of occupational health staffs and personnel/labor staffs, we selected higher-priority scales from the standard version. After selecting one item with highest item-total correlation coefficient from each scale, a 23-item questionnaire was developed. A nationally representative survey was administered to Japanese employees (n=1,633) to examine test-retest reliability and validity. Most scales (or items) showed modest but adequate levels of test-retest reliability (r>0.50). Furthermore, job demands and job resources scales (or items) were associated with mental and physical stress reactions while job resources scales (or items) were also associated with positive outcomes. These findings provided a piece of evidence that the short version of the New BJSQ is reliable and valid.
Development of a Short Version of the New Brief Job Stress Questionnaire
INOUE, Akiomi; KAWAKAMI, Norito; SHIMOMITSU, Teruichi; TSUTSUMI, Akizumi; HARATANI, Takashi; YOSHIKAWA, Toru; SHIMAZU, Akihito; ODAGIRI, Yuko
2014-01-01
This study was aimed to investigate the test-retest reliability and validity of a short version of the New Brief Job Stress Questionnaire (New BJSQ) whose scales have one item selected from a standard version. Based on the results from an anonymous web-based questionnaire of occupational health staffs and personnel/labor staffs, we selected higher-priority scales from the standard version. After selecting one item with highest item-total correlation coefficient from each scale, a 23-item questionnaire was developed. A nationally representative survey was administered to Japanese employees (n=1,633) to examine test-retest reliability and validity. Most scales (or items) showed modest but adequate levels of test-retest reliability (r>0.50). Furthermore, job demands and job resources scales (or items) were associated with mental and physical stress reactions while job resources scales (or items) were also associated with positive outcomes. These findings provided a piece of evidence that the short version of the New BJSQ is reliable and valid. PMID:24975108
Chavaillaz, Alain; Schwaninger, Adrian; Michel, Stefan; Sauer, Juergen
2018-05-25
The present study evaluated three automation modes for improving performance in an X-ray luggage screening task. 140 participants were asked to detect the presence of prohibited items in X-ray images of cabin luggage. Twenty participants conducted this task without automatic support (control group), whereas the others worked with either indirect cues (system indicated the target presence without specifying its location), or direct cues (system pointed out the exact target location) or adaptable automation (participants could freely choose between no cue, direct and indirect cues). Furthermore, automatic support reliability was manipulated (low vs. high). The results showed a clear advantage for direct cues regarding detection performance and response time. No benefits were observed for adaptable automation. Finally, high automation reliability led to better performance and higher operator trust. The findings overall confirmed that automatic support systems for luggage screening should be designed such that they provide direct, highly reliable cues.
Reliability and validity of a Swedish language version of the Resilience Scale.
Nygren, Björn; Randström, Kerstin Björkman; Lejonklou, Anna K; Lundman, Beril
2004-01-01
The purpose of this study was to test the reliability and validity of the Swedish language version of the Resilience Scale (RS). Participants were 142 adults between 19-85 years of age. Internal consistency reliability, stability over time, and construct validity were evaluated using Cronbach's alpha, principal components analysis with varimax rotation and correlations with scores on the Sense of Coherence Scale (SOC) and the Rosenberg Self-Esteem Scale (RSE). The mean score on the RS was 142 (SD = 15). The possible scores on the RS range from 25 to 175, and scores higher than 146 are considered high. The test-retest correlation was .78. Correlations with the SOC and the RSE were .41 (p < 0.01) and .37 (p < 0.01), respectively. Personal Assurance and Acceptance of Self and Life emerged as components from the principal components analysis. These findings provide evidence for the reliability and validity of the Swedish language version of the RS.
Fatigue after stroke: the development and evaluation of a case definition.
Lynch, Joanna; Mead, Gillian; Greig, Carolyn; Young, Archie; Lewis, Susan; Sharpe, Michael
2007-11-01
While fatigue after stroke is a common problem, it has no generally accepted definition. Our aim was to develop a case definition for post-stroke fatigue and to test its psychometric properties. A case definition with face validity and an associated structured interview was constructed. After initial piloting, the feasibility, reliability (test-retest and inter-rater) and concurrent validity (in relation to four fatigue severity scales) were determined in 55 patients with stroke. All participating patients provided satisfactory answers to all the case definition probe questions demonstrating its feasibility For test-retest reliability, kappa was 0.78 (95% CI, 0.57-0.94, P<.01) and for inter-rater reliability kappa was 0.80 (95% CI, 0.62-0.99, P<.01). Patients fulfilling the case definition also had substantially higher fatigue scores on four fatigue severity scales (P<.001) indicating concurrent validity. The proposed case definition is feasible to administer and reliable in practice, and there is evidence of concurrent validity. It requires further evaluation in different settings.
2010-01-01
Background Hispanics comprise the largest ethnic minority group in the United States. Previous work with the Spanish Modified Dental Anxiety Scale (MDAS) yielded good validity, but lower test-retest reliability. We report the performance of the Spanish MDAS in a new sample, as well as the performance of the Spanish Revised Dental Beliefs Survey (R-DBS). Methods One hundred sixty two Spanish-speaking adults attending Spanish-language church services or an Hispanic cultural festival completed questionnaires containing the Spanish MDAS, Spanish R-DBS, and dental attendance questions, and underwent a brief oral examination. Church attendees completed the questionnaire a second time, for test-retest purposes. Results The Spanish MDAS and R-DBS were completed by 156 and 136 adults, respectively. The test-retest reliability of the Spanish MDAS was 0.83 (95% CI = 0.60-0.92). The internal reliability of the Spanish R-DBS was 0.96 (95% CI = 0.94-0.97), and the test-retest reliability was 0.86 (95% CI = 0.64-0.94). The two measures were significantly correlated (Spearman's rho = 0.38, p < 0.001). Participants who do not currently go to a dentist had significantly higher MDAS scores (t = 3.40, df = 106, p = 0.003) as well as significantly higher R-DBS scores (t = 2.21, df = 131, p = 0.029). Participants whose most recent dental visit was for pain or a problem, rather than for a check-up, scored significantly higher on both the MDAS (t = 3.00, df = 106, p = 0.003) and the R-DBS (t = 2.85, df = 92, p = 0.005). Those with high dental fear (MDAS score 19 or greater) were significantly more likely to have severe caries (Chi square = 6.644, df = 2, p = 0.036). Higher scores on the R-DBS were significantly related to having more missing teeth (Spearman's rho = 0.23, p = 0.009). Conclusion In this sample, the test-retest reliability of the Spanish MDAS was higher. The significant relationships between dental attendance and questionnaire scores, as well as the difference in caries severity seen in those with high fear, add to the evidence of this scale's construct validity in Hispanic samples. Our results also provide evidence for the internal and test-retest reliabilities, as well as the construct validity, of the Spanish R-DBS. PMID:20465835
Compact dewar and electronics for large-format infrared detectors
NASA Astrophysics Data System (ADS)
Manissadjian, A.; Magli, S.; Mallet, E.; Cassaigne, P.
2011-06-01
Infrared systems cameras trend is to require higher performance (thanks to higher resolution) and in parallel higher compactness for easier integration in systems. The latest developments at SOFRADIR / France on HgCdTe (Mercury Cadmium Telluride / MCT) cooled IR staring detectors do show constant improvements regarding detector performances and compactness, by reducing the pixel pitch and optimizing their encapsulation. Among the latest introduced detectors, the 15μm pixel pitch JUPITER HD-TV format (1280×1024) has to deal with challenging specifications regarding dewar compactness, low power consumption and reliability. Initially introduced four years ago in a large dewar with a more than 2kg split Stirling cooler compressor, it is now available in a new versatile compact dewar that is vacuum-maintenance-free over typical 18 years mission profiles, and that can be integrated with the different available Stirling coolers: K548 microcooler for light solution (less than 0.7 kg), K549 or LSF9548 for split cooler and/or higher reliability solution. The IDDCAs are also required with simplified electrical interface enabling to shorten the system development time and to standardize the electronic boards definition with smaller volumes. Sofradir is therefore introducing MEGALINK, the new compact Command & Control Electronics compatible with most of the Sofradir IDDCAs. MEGALINK provides all necessary input biases and clocks to the FPAs, and digitizes and multiplexes the video outputs to provide a 14 bit output signal through a cameralink interface, in a surface smaller than a business card.
High power diode lasers emitting from 639 nm to 690 nm
NASA Astrophysics Data System (ADS)
Bao, L.; Grimshaw, M.; DeVito, M.; Kanskar, M.; Dong, W.; Guan, X.; Zhang, S.; Patterson, J.; Dickerson, P.; Kennedy, K.; Li, S.; Haden, J.; Martinsen, R.
2014-03-01
There is increasing market demand for high power reliable red lasers for display and cinema applications. Due to the fundamental material system limit at this wavelength range, red diode lasers have lower efficiency and are more temperature sensitive, compared to 790-980 nm diode lasers. In terms of reliability, red lasers are also more sensitive to catastrophic optical mirror damage (COMD) due to the higher photon energy. Thus developing higher power-reliable red lasers is very challenging. This paper will present nLIGHT's released red products from 639 nm to 690nm, with established high performance and long-term reliability. These single emitter diode lasers can work as stand-alone singleemitter units or efficiently integrate into our compact, passively-cooled Pearl™ fiber-coupled module architectures for higher output power and improved reliability. In order to further improve power and reliability, new chip optimizations have been focused on improving epitaxial design/growth, chip configuration/processing and optical facet passivation. Initial optimization has demonstrated promising results for 639 nm diode lasers to be reliably rated at 1.5 W and 690nm diode lasers to be reliably rated at 4.0 W. Accelerated life-test has started and further design optimization are underway.
Wafer level reliability for high-performance VLSI design
NASA Technical Reports Server (NTRS)
Root, Bryan J.; Seefeldt, James D.
1987-01-01
As very large scale integration architecture requires higher package density, reliability of these devices has approached a critical level. Previous processing techniques allowed a large window for varying reliability. However, as scaling and higher current densities push reliability to its limit, tighter control and instant feedback becomes critical. Several test structures developed to monitor reliability at the wafer level are described. For example, a test structure was developed to monitor metal integrity in seconds as opposed to weeks or months for conventional testing. Another structure monitors mobile ion contamination at critical steps in the process. Thus the reliability jeopardy can be assessed during fabrication preventing defective devices from ever being placed in the field. Most importantly, the reliability can be assessed on each wafer as opposed to an occasional sample.
Validating the Riverside Acculturation Stress Inventory with Asian Americans.
Miller, Matthew J; Kim, Jungeun; Benet-Martínez, Verónica
2011-06-01
An emerging body of empirical research highlights the impact of acculturative stress in the lives of culturally diverse populations. Therefore, to facilitate future research in this area, we conducted 3 studies to examine the psychometric properties of the Riverside Acculturation Stress Inventory (RASI; Benet-Martínez & Haritatos, 2005) and its 5 subscales in a total sample of 793 self-identified Asian American participants. The reliability and validity of RASI scores and the hypothesized 1-factor higher order model (with 1st-order factors Language Skills, Work Challenges, Intercultural Relations, Discrimination, and Cultural Isolation) of the RASI were examined in Study 1. The RASI higher order structure and score validity and reliability were examined across different generational groups in Study 2. The stability of RASI scores over a 3-week period was examined in Study 3. Overall, findings from these studies support the hypothesized structure of the RASI and indicate that this brief instrument provides reliable and valid acculturative stress scores. In addition, results suggest that RASI items are interpreted in an equivalent manner across different generations of Asian American individuals. Implications for research and assessment are discussed. 2011 APA, all rights reserved
O'Brien, Anna; Keidser, Gitte; Yeend, Ingrid; Hartley, Lisa; Dillon, Harvey
2010-12-01
Audiometric measurements through a hearing aid ('in-situ') may facilitate provision of hearing services where these are limited. This study investigated the validity and reliability of in-situ air conduction hearing thresholds measured with closed and open domes relative to thresholds measured with insert earphones, and explored sources of variability in the measures. Twenty-four adults with sensorineural hearing impairment attended two sessions in which thresholds and real-ear-to-dial-difference (REDD) values were measured. Without correction, significantly higher low-frequency thresholds in dB HL were measured in-situ than with insert earphones. Differences were due predominantly to differences in ear canal SPL, as measured with the REDD, which were attributed to leaking low-frequency energy. Test-retest data yielded higher variability with the closed dome coupling due to inconsistent seals achieved with this tip. For all three conditions, inter-participant variability in the REDD values was greater than intra-participant variability. Overall, in-situ audiometry is as valid and reliable as conventional audiometry provided appropriate REDD corrections are made and ambient sound in the test environment is controlled.
Lee, Kyoung Min; Lee, Jaebong; Chung, Chin Youb; Ahn, Soyeon; Sung, Ki Hyuk; Kim, Tae Won; Lee, Hui Jong; Park, Moon Seok
2012-06-01
Intra-class correlation coefficients (ICCs) provide a statistical means of testing the reliability. However, their interpretation is not well documented in the orthopedic field. The purpose of this study was to investigate the use of ICCs in the orthopedic literature and to demonstrate pitfalls regarding their use. First, orthopedic articles that used ICCs were retrieved from the Pubmed database, and journal demography, ICC models and concurrent statistics used were evaluated. Second, reliability test was performed on three common physical examinations in cerebral palsy, namely, the Thomas test, the Staheli test, and popliteal angle measurement. Thirty patients were assessed by three orthopedic surgeons to explore the statistical methods testing reliability. Third, the factors affecting the ICC values were examined by simulating the data sets based on the physical examination data where the ranges, slopes, and interobserver variability were modified. Of the 92 orthopedic articles identified, 58 articles (63%) did not clarify the ICC model used, and only 5 articles (5%) described all models, types, and measures. In reliability testing, although the popliteal angle showed a larger mean absolute difference than the Thomas test and the Staheli test, the ICC of popliteal angle was higher, which was believed to be contrary to the context of measurement. In addition, the ICC values were affected by the model, type, and measures used. In simulated data sets, the ICC showed higher values when the range of data sets were larger, the slopes of the data sets were parallel, and the interobserver variability was smaller. Care should be taken when interpreting the absolute ICC values, i.e., a higher ICC does not necessarily mean less variability because the ICC values can also be affected by various factors. The authors recommend that researchers clarify ICC models used and ICC values are interpreted in the context of measurement.
McCaffrey, Ruth; Bishop, Mary; Adonis-Rizzo, Marie; Williamson, Ellen; McPherson, Melanie; Cruikshank, Alice; Carrier, Vicki Jo; Sands, Simone; Pigano, Diane; Girard, Patricia; Lauzon, Cathy
2007-01-01
Hospital-acquired deep vein thrombosis (DVT) and pulmonary embolisms (PE) are preventable problems that can increase mortality. Early assessment and recognition of risk as well as initiating appropriate prevention measures can prevent DVT or PE. The purpose of this research project was to develop a DVT risk assessment tool and test the tool for validity and reliability. Three phases were undertaken in developing and testing the JFK Medical Center DVT risk assessment tool. Investigation and clarification of risk and predisposing factors for DVT were identified from the literature, expert nursing knowledge, and medical staff input. Second, item development and weighting were undertaken. Third, parametric testing for content validity measured the differences in mean assessment tool scores between a group of patients who developed DVT in the hospital and a demographically similar group who did not develop DVT. Interrater reliability was measured by having three different nurses score each patient and compare the differences in scores among the three. The DVT group had significantly higher scores on the JFK DVT assessment scale than did those who did not experience DVT. Interrater reliability showed a strong correlation among the scores of the three nurses (.98). Providing a valid and reliable tool for measuring the risk for DVT or PE in hospitalized patients will enable nurses to intervene early in patients at risk. Basing DVT risk assessment on the evidence provided in this study will assist nurses in becoming more confident in recognizing the necessity for interventions in hospitalized patients and decreasing risk. Nurses can now evaluate patients at risk for DVT or PE using the JFK Medial Center's risk assessment tool.
Coolidge, T; Heima, M; Heaton, L J; Nakai, Y; Höskuldsson, O; Smith, T A; Weinstein, P; Milgrom, P
2005-03-01
The Child Dental Control Assessment (CDCA) measures children's preferred control strategies in the dental situation. Three studies are reported, assessing aspects of this instrument in youths from the USA, Japan and Australia. In particular, measurements were made as to the reliability and validity of this instrument in this age group in the three cultures, as well as comparing some results across cultures. These studies used a questionnaire design. Questionnaires (including the CDCA and other measures) were given to youths aged 11-15 in the three cultures. In one culture, youths received the questionnaire twice, to compute test-retest reliability. The measure's reliability and validity were similar to those of other measures. The CDCA behaves similarly to the Revised Iowa Dental Control Index (R-IDCI). Youths in all three cultures showed similar responses, although the Japanese were less likely to endorse items. Internal reliability of the scale ranged from 0.74 to 0.85. Test- retest reliability was 0.74. Participants in the High Desire/Low Predicted classification on the R-IDCI scored higher on the CDCA (t (73) = 2.9, p < .01). In the Japanese and Australian samples the correlation between CDCA and dental fear was 0.29-0.33 (p < .001). The Australian and USA samples scored significantly higher than the Japanese sample (overall F(2,1544) = 383.98, p < .001, followed by Tukey's HSD, p < .001). These results provide evidence for the reliability and validity of the CDCA in youth. It appears to measure the discrepancy between Desired and Predicted Control identified in the Revised Iowa Dental Control Index (R-IDCI). Responses of the youth in all three cultures were similar, indicating common dental control preferences for individuals of this age. However, consistent with cultural values, Japanese youth were less likely to endorse the control strategies. These results underline the need to develop culturally-specific, as well as situationally-specific control measures.
Lei, Pingguang; Lei, Guanghe; Tian, Jianjun; Zhou, Zengfen; Zhao, Miao; Wan, Chonghua
2014-10-01
This paper is aimed to develop the irritable bowel syndrome (IBS) scale of the system of Quality of Life Instruments for Chronic Diseases (QLICD-IBS) by the modular approach and validate it by both classical test theory and generalizability theory. The QLICD-IBS was developed based on programmed decision procedures with multiple nominal and focus group discussions, in-depth interview, and quantitative statistical procedures. One hundred twelve inpatients with IBS were used to provide the data measuring QOL three times before and after treatments. The psychometric properties of the scale were evaluated with respect to validity, reliability, and responsiveness employing correlation analysis, factor analyses, multi-trait scaling analysis, t tests and also G studies and D studies of generalizability theory analysis. Multi-trait scaling analysis, correlation, and factor analyses confirmed good construct validity and criterion-related validity when using SF-36 as a criterion. Test-retest reliability coefficients (Pearson r and intra-class correlation (ICC)) for the overall score and all domains were higher than 0.80; the internal consistency α for all domains at two measurements were higher than 0.70 except for the social domain (0.55 and 0.67, respectively). The overall score and scores for all domains/facets had statistically significant changes after treatments with moderate or higher effect size standardized response mean (SRM) ranging from 0.72 to 1.02 at domain levels. G coefficients and index of dependability (Ф coefficients) confirmed the reliability of the scale further with more exact variance components. The QLICD-IBS has good validity, reliability, responsiveness, and some highlights and can be used as the quality of life instrument for patients with IBS.
Schneid, Stephen D; Armour, Chris; Park, Yoon Soo; Yudkowsky, Rachel; Bordage, Georges
2014-10-01
Despite significant evidence supporting the use of three-option multiple-choice questions (MCQs), these are rarely used in written examinations for health professions students. The purpose of this study was to examine the effects of reducing four- and five-option MCQs to three-option MCQs on response times, psychometric characteristics, and absolute standard setting judgements in a pharmacology examination administered to health professions students. We administered two versions of a computerised examination containing 98 MCQs to 38 Year 2 medical students and 39 Year 3 pharmacy students. Four- and five-option MCQs were converted into three-option MCQs to create two versions of the examination. Differences in response time, item difficulty and discrimination, and reliability were evaluated. Medical and pharmacy faculty judges provided three-level Angoff (TLA) ratings for all MCQs for both versions of the examination to allow the assessment of differences in cut scores. Students answered three-option MCQs an average of 5 seconds faster than they answered four- and five-option MCQs (36 seconds versus 41 seconds; p = 0.008). There were no significant differences in item difficulty and discrimination, or test reliability. Overall, the cut scores generated for three-option MCQs using the TLA ratings were 8 percentage points higher (p = 0.04). The use of three-option MCQs in a health professions examination resulted in a time saving equivalent to the completion of 16% more MCQs per 1-hour testing period, which may increase content validity and test score reliability, and minimise construct under-representation. The higher cut scores may result in higher failure rates if an absolute standard setting method, such as the TLA method, is used. The results from this study provide a cautious indication to health professions educators that using three-option MCQs does not threaten validity and may strengthen it by allowing additional MCQs to be tested in a fixed amount of testing time with no deleterious effect on the reliability of the test scores. © 2014 John Wiley & Sons Ltd.
Soft-Fault Detection Technologies Developed for Electrical Power Systems
NASA Technical Reports Server (NTRS)
Button, Robert M.
2004-01-01
The NASA Glenn Research Center, partner universities, and defense contractors are working to develop intelligent power management and distribution (PMAD) technologies for future spacecraft and launch vehicles. The goals are to provide higher performance (efficiency, transient response, and stability), higher fault tolerance, and higher reliability through the application of digital control and communication technologies. It is also expected that these technologies will eventually reduce the design, development, manufacturing, and integration costs for large, electrical power systems for space vehicles. The main focus of this research has been to incorporate digital control, communications, and intelligent algorithms into power electronic devices such as direct-current to direct-current (dc-dc) converters and protective switchgear. These technologies, in turn, will enable revolutionary changes in the way electrical power systems are designed, developed, configured, and integrated in aerospace vehicles and satellites. Initial successes in integrating modern, digital controllers have proven that transient response performance can be improved using advanced nonlinear control algorithms. One technology being developed includes the detection of "soft faults," those not typically covered by current systems in use today. Soft faults include arcing faults, corona discharge faults, and undetected leakage currents. Using digital control and advanced signal analysis algorithms, we have shown that it is possible to reliably detect arcing faults in high-voltage dc power distribution systems (see the preceding photograph). Another research effort has shown that low-level leakage faults and cable degradation can be detected by analyzing power system parameters over time. This additional fault detection capability will result in higher reliability for long-lived power systems such as reusable launch vehicles and space exploration missions.
Branco, Paulo; Seixas, Daniela; Castro, São Luís
2018-03-01
Resting-state fMRI is a well-suited technique to map functional networks in the brain because unlike task-based approaches it requires little collaboration from subjects. This is especially relevant in clinical settings where a number of subjects cannot comply with task demands. Previous studies using conventional scanner fields have shown that resting-state fMRI is able to map functional networks in single subjects, albeit with moderate temporal reliability. Ultra-high resolution (7T) imaging provides higher signal-to-noise ratio and better spatial resolution and is thus well suited to assess the temporal reliability of mapping results, and to determine if resting-state fMRI can be applied in clinical decision making including preoperative planning. We used resting-state fMRI at ultra-high resolution to examine whether the sensorimotor and language networks are reliable over time - same session and one week after. Resting-state networks were identified for all subjects and sessions with good accuracy. Both networks were well delimited within classical regions of interest. Mapping was temporally reliable at short and medium time-scales as demonstrated by high values of overlap in the same session and one week after for both networks. Results were stable independently of data quality metrics and physiological variables. Taken together, these findings provide strong support for the suitability of ultra-high field resting-state fMRI mapping at the single-subject level. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
FY12 End of Year Report for NEPP DDR2 Reliability
NASA Technical Reports Server (NTRS)
Guertin, Steven M.
2013-01-01
This document reports the status of the NASA Electronic Parts and Packaging (NEPP) Double Data Rate 2 (DDR2) Reliability effort for FY2012. The task expanded the focus of evaluating reliability effects targeted for device examination. FY11 work highlighted the need to test many more parts and to examine more operating conditions, in order to provide useful recommendations for NASA users of these devices. This year's efforts focused on development of test capabilities, particularly focusing on those that can be used to determine overall lot quality and identify outlier devices, and test methods that can be employed on components for flight use. Flight acceptance of components potentially includes considerable time for up-screening (though this time may not currently be used for much reliability testing). Manufacturers are much more knowledgeable about the relevant reliability mechanisms for each of their devices. We are not in a position to know what the appropriate reliability tests are for any given device, so although reliability testing could be focused for a given device, we are forced to perform a large campaign of reliability tests to identify devices with degraded reliability. With the available up-screening time for NASA parts, it is possible to run many device performance studies. This includes verification of basic datasheet characteristics. Furthermore, it is possible to perform significant pattern sensitivity studies. By doing these studies we can establish higher reliability of flight components. In order to develop these approaches, it is necessary to develop test capability that can identify reliability outliers. To do this we must test many devices to ensure outliers are in the sample, and we must develop characterization capability to measure many different parameters. For FY12 we increased capability for reliability characterization and sample size. We increased sample size this year by moving from loose devices to dual inline memory modules (DIMMs) with an approximate reduction of 20 to 50 times in terms of per device under test (DUT) cost. By increasing sample size we have improved our ability to characterize devices that may be considered reliability outliers. This report provides an update on the effort to improve DDR2 testing capability. Although focused on DDR2, the methods being used can be extended to DDR and DDR3 with relative ease.
WindTalker: A P2P-Based Low-Latency Anonymous Communication Network
NASA Astrophysics Data System (ADS)
Zhang, Jia; Duan, Haixin; Liu, Wu; Wu, Jianping
Compared with traditional static anonymous communication networks, the P2P architecture can provide higher anonymity in communication. However, the P2P architecture also leads to more challenges, such as route, stability, trust and so on. In this paper, we present WindTalker, a P2P-based low-latency anonymous communication network. It is a pure decentralized mix network and can provide low-latency services which help users hide their real identity in communication. In order to ensure stability and reliability, WindTalker imports “seed nodes” to help a peer join in the P2P network and the peer nodes can use gossip-based protocol to exchange active information. Moreover, WindTalker uses layer encryption to ensure the information of relayed messages cannot be leaked. In addition, malicious nodes in the network are the major threat to anonymity of P2P anonymous communication, so WindTalker imports a trust mechanism which can help the P2P network exclude malicious nodes and optimize the strategy of peer discovery, tunnel construction, and relaying etc. in anonymous communications. We deploy peer nodes of WindTalker in our campus network to test reliability and analyze anonymity in theory. The network measurement and simulation analysis shows that WindTalker can provide low-latency and reliable anonymous communication services.
Guide to Cybersecurity, Resilience, and Reliability for Small and Under-Resourced Utilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ingram, Michael; Martin, Maurice
Small electricity utilities -- those with less than 100 employees or 50,000 meters -- provide essential services to large parts of the United States while facing a number of challenges unique to their mission. For instance, they often serve areas that are sparsely populated, meaning that their per-customer cost to provide service is higher. At the same time, they often serve customers that have moderate or fixed incomes, meaning that they are under strong pressure to keep costs down. This pressure puts them on a strict budget and creates a need for innovative solutions to common problems. Further, their servicemore » areas may include extreme climates, making severe weather events more frequent and their aftermaths more expensive to address. This guide considers challenges that small utilities face while ensuring the reliability, resilience, and cybersecurity of their electric service; approaches to address those challenges using existing guidance documents; ways that the federal government could provide support in these areas.« less
A human reliability based usability evaluation method for safety-critical software
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boring, R. L.; Tran, T. Q.; Gertman, D. I.
2006-07-01
Boring and Gertman (2005) introduced a novel method that augments heuristic usability evaluation methods with that of the human reliability analysis method of SPAR-H. By assigning probabilistic modifiers to individual heuristics, it is possible to arrive at the usability error probability (UEP). Although this UEP is not a literal probability of error, it nonetheless provides a quantitative basis to heuristic evaluation. This method allows one to seamlessly prioritize and identify usability issues (i.e., a higher UEP requires more immediate fixes). However, the original version of this method required the usability evaluator to assign priority weights to the final UEP, thusmore » allowing the priority of a usability issue to differ among usability evaluators. The purpose of this paper is to explore an alternative approach to standardize the priority weighting of the UEP in an effort to improve the method's reliability. (authors)« less
Cintas, Holly Lea; Parks, Rebecca; Don, Sarah; Gerber, Lynn
2011-01-01
Content validity and reliability of the Brief Assessment of Motor Function (BAMF) Upper Extremity Gross Motor Scale (UEGMS) were evaluated in this prospective, descriptive study. The UEGMS is one of five ordinal scales designed for quick documentation of gross, fine and oral motor skill levels. Designed to be independent of age and diagnosis, it is intended for use for infants through young adults. An expert panel of 17 physical therapists and 13 occupational therapists refined the content by responding to a standard questionnaire comprised of questions which asked whether each item should be included, is clearly worded, should be reordered higher or lower, is functionally relevant, and is easily discriminated. Ratings of content validity exceeded the criterion except for two items which may represent different perspectives of physical and occupational therapists. The UEGMS was modified using the quantitative and qualitative feedback from the questionnaires. For reliability, five raters scored videotaped motor performances of ten children. Coefficients for inter-rater (0.94) and intra-rater (0.95) reliability were high. The results provide evidence of content validity and reliability of the UEGMS for assessment of upper extremity gross motor skill. PMID:21599568
Design, Implementation, and Verification of the Reliable Multicast Protocol. Thesis
NASA Technical Reports Server (NTRS)
Montgomery, Todd L.
1995-01-01
This document describes the Reliable Multicast Protocol (RMP) design, first implementation, and formal verification. RMP provides a totally ordered, reliable, atomic multicast service on top of an unreliable multicast datagram service. RMP is fully and symmetrically distributed so that no site bears an undue portion of the communications load. RMP provides a wide range of guarantees, from unreliable delivery to totally ordered delivery, to K-resilient, majority resilient, and totally resilient atomic delivery. These guarantees are selectable on a per message basis. RMP provides many communication options, including virtual synchrony, a publisher/subscriber model of message delivery, a client/server model of delivery, mutually exclusive handlers for messages, and mutually exclusive locks. It has been commonly believed that total ordering of messages can only be achieved at great performance expense. RMP discounts this. The first implementation of RMP has been shown to provide high throughput performance on Local Area Networks (LAN). For two or more destinations a single LAN, RMP provides higher throughput than any other protocol that does not use multicast or broadcast technology. The design, implementation, and verification activities of RMP have occurred concurrently. This has allowed the verification to maintain a high fidelity between design model, implementation model, and the verification model. The restrictions of implementation have influenced the design earlier than in normal sequential approaches. The protocol as a whole has matured smoother by the inclusion of several different perspectives into the product development.
Wood, David L; Sawicki, Gregory S; Miller, M David; Smotherman, Carmen; Lukens-Bull, Katryne; Livingood, William C; Ferris, Maria; Kraemer, Dale F
2014-01-01
National consensus statements recommend that providers regularly assess the transition readiness skills of adolescent and young adults (AYA). In 2010 we developed a 29-item version of Transition Readiness Assessment Questionnaire (TRAQ). We reevaluated item performance and factor structure, and reassessed the TRAQ's reliability and validity. We surveyed youth from 3 academic clinics in Jacksonville, Florida; Chapel Hill, North Carolina; and Boston, Massachusetts. Participants were AYA with special health care needs aged 14 to 21 years. From a convenience sample of 306 patients, we conducted item reduction strategies and exploratory factor analysis (EFA). On a second convenience sample of 221 patients, we conducted confirmatory factor analysis (CFA). Internal reliability was assessed by Cronbach's alpha and criterion validity. Analyses were conducted by the Wilcoxon rank sum test and mixed linear models. The item reduction and EFA resulted in a 20-item scale with 5 identified subscales. The CFA conducted on a second sample provided a good fit to the data. The overall scale has high reliability overall (Cronbach's alpha = .94) and good reliability for 4 of the 5 subscales (Cronbach's alpha ranging from .90 to .77 in the pooled sample). Each of the 5 subscale scores were significantly higher for adolescents aged 18 years and older versus those younger than 18 (P < .0001) in both univariate and multivariate analyses. The 20-item, 5-factor structure for the TRAQ is supported by EFA and CFA on independent samples and has good internal reliability and criterion validity. Additional work is needed to expand or revise the TRAQ subscales and test their predictive validity. Copyright © 2014 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.
DiClemente, Carlo C; Crouch, Taylor Berens; Norwood, Amber E Q; Delahanty, Janine; Welsh, Christopher
2015-03-01
Screening, brief intervention, and referral to treatment (SBIRT) has become an empirically supported and widely implemented approach in primary and specialty care for addressing substance misuse. Accordingly, training of providers in SBIRT has increased exponentially in recent years. However, the quality and fidelity of training programs and subsequent interventions are largely unknown because of the lack of SBIRT-specific evaluation tools. The purpose of this study was to create a coding scale to assess quality and fidelity of SBIRT interactions addressing alcohol, tobacco, illicit drugs, and prescription medication misuse. The scale was developed to evaluate performance in an SBIRT residency training program. Scale development was based on training protocol and competencies with consultation from Motivational Interviewing coding experts. Trained medical residents practiced SBIRT with standardized patients during 10- to 15-min videotaped interactions. This study included 25 tapes from the Family Medicine program coded by 3 unique coder pairs with varying levels of coding experience. Interrater reliability was assessed for overall scale components and individual items via intraclass correlation coefficients. Coder pair-specific reliability was also assessed. Interrater reliability was excellent overall for the scale components (>.85) and nearly all items. Reliability was higher for more experienced coders, though still adequate for the trained coder pair. Descriptive data demonstrated a broad range of adherence and skills. Subscale correlations supported concurrent and discriminant validity. Data provide evidence that the MD3 SBIRT Coding Scale is a psychometrically reliable coding system for evaluating SBIRT interactions and can be used to evaluate implementation skills for fidelity, training, assessment, and research. Recommendations for refinement and further testing of the measure are discussed. (PsycINFO Database Record (c) 2015 APA, all rights reserved).
Hotham, S; Hutton, E; Hamilton-West, K E
2015-11-01
Previous research has highlighted lack of knowledge, understanding and confidence among parents and teachers responsible for the postural care of children with physical disability. Interventions designed to improve these qualities require a reliable and validated tool to assess pre- and post-intervention levels. Currently, however, no validated measure of postural care confidence (i.e. self-efficacy) exists. Hence, the aim of this research was to develop a reliable and valid questionnaire to assess parents' and teachers' confidence, alongside knowledge and understanding of postural care - the Understanding Knowledge and Confidence in providing POSTural CARe for children with Disabilities (UKC PostCarD) questionnaire. Items were developed by a multidisciplinary team and designed to map onto the content of 'An A-to-Z of Postural Care'. Parents, teachers and therapists assessed items for face validity. Scale reliability was then assessed using Cronbach's alpha and known-group validity was assessed by comparing scores of an 'expert' group (physiotherapists and occupational therapists) with those of a 'non-expert' group (with no formal training in postural care). The total scale and all three subscales (understanding and knowledge, confidence and concerns) demonstrated adequate reliability (α > 0.83) and subscale correlations formed a logical pattern (understanding and knowledge correlated positively with confidence and negatively with concerns). Experts' (n = 111) scores were higher than non-experts' (n = 79) for the total scale and all subscales (P < 0.001). Findings support the reliability and validity of the UKC PostCarD questionnaire as a measure of understanding, knowledge and confidence in providing postural care for children with disabilities. © 2015 John Wiley & Sons Ltd.
DC Microgrids Scoping Study. Estimate of Technical and Economic Benefits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Backhaus, Scott N.; Swift, Gregory William; Chatzivasileiadis, Spyridon
Microgrid demonstrations and deployments are expanding in US power systems and around the world. Although goals are specific to each site, these microgrids have demonstrated the ability to provide higher reliability and higher power quality than utility power systems and improved energy utilization. The vast majority of these microgrids are based on AC power transfer because this has been the traditionally dominant power delivery scheme. Independently, manufacturers, power system designers and researchers are demonstrating and deploying DC power distribution systems for applications where the end-use loads are natively DC, e.g., computers, solid-state lighting, and building networks. These early DC applicationsmore » may provide higher efficiency, added flexibility, reduced capital costs over their AC counterparts. Further, when onsite renewable generation, electric vehicles and storage systems are present, DC-based microgrids may offer additional benefits. Early successes from these efforts raises a question - can a combination of microgrid concepts and DC distribution systems provide added benefits beyond what has been achieved individually?« less
Connors, Brenda L.; Rende, Richard; Colton, Timothy J.
2014-01-01
The unique yield of collecting observational data on human movement has received increasing attention in a number of domains, including the study of decision-making style. As such, interest has grown in the nuances of core methodological issues, including the best ways of assessing inter-rater reliability. In this paper we focus on one key topic – the distinction between establishing reliability for the patterning of behaviors as opposed to the computation of raw counts – and suggest that reliability for each be compared empirically rather than determined a priori. We illustrate by assessing inter-rater reliability for key outcome measures derived from movement pattern analysis (MPA), an observational methodology that records body movements as indicators of decision-making style with demonstrated predictive validity. While reliability ranged from moderate to good for raw counts of behaviors reflecting each of two Overall Factors generated within MPA (Assertion and Perspective), inter-rater reliability for patterning (proportional indicators of each factor) was significantly higher and excellent (ICC = 0.89). Furthermore, patterning, as compared to raw counts, provided better prediction of observable decision-making process assessed in the laboratory. These analyses support the utility of using an empirical approach to inform the consideration of measuring patterning versus discrete behavioral counts of behaviors when determining inter-rater reliability of observable behavior. They also speak to the substantial reliability that may be achieved via application of theoretically grounded observational systems such as MPA that reveal thinking and action motivations via visible movement patterns. PMID:24999336
Connors, Brenda L; Rende, Richard; Colton, Timothy J
2014-01-01
The unique yield of collecting observational data on human movement has received increasing attention in a number of domains, including the study of decision-making style. As such, interest has grown in the nuances of core methodological issues, including the best ways of assessing inter-rater reliability. In this paper we focus on one key topic - the distinction between establishing reliability for the patterning of behaviors as opposed to the computation of raw counts - and suggest that reliability for each be compared empirically rather than determined a priori. We illustrate by assessing inter-rater reliability for key outcome measures derived from movement pattern analysis (MPA), an observational methodology that records body movements as indicators of decision-making style with demonstrated predictive validity. While reliability ranged from moderate to good for raw counts of behaviors reflecting each of two Overall Factors generated within MPA (Assertion and Perspective), inter-rater reliability for patterning (proportional indicators of each factor) was significantly higher and excellent (ICC = 0.89). Furthermore, patterning, as compared to raw counts, provided better prediction of observable decision-making process assessed in the laboratory. These analyses support the utility of using an empirical approach to inform the consideration of measuring patterning versus discrete behavioral counts of behaviors when determining inter-rater reliability of observable behavior. They also speak to the substantial reliability that may be achieved via application of theoretically grounded observational systems such as MPA that reveal thinking and action motivations via visible movement patterns.
Online Studies on Variation in Orthopedic Surgery: Computed Tomography in MPEG4 Versus DICOM Format.
Mellema, Jos J; Mallee, Wouter H; Guitton, Thierry G; van Dijk, C Niek; Ring, David; Doornberg, Job N
2017-10-01
The purpose of this study was to compare the observer participation and satisfaction as well as interobserver reliability between two online platforms, Science of Variation Group (SOVG) and Traumaplatform Study Collaborative, for the evaluation of complex tibial plateau fractures using computed tomography in MPEG4 and DICOM format. A total of 143 observers started with the online evaluation of 15 complex tibial plateau fractures via either the SOVG or Traumaplatform Study Collaborative websites using MPEG4 videos or a DICOM viewer, respectively. Observers were asked to indicate the absence or presence of four tibial plateau fracture characteristics and to rate their satisfaction with the evaluation as provided by the respective online platforms. The observer participation rate was significantly higher in the SOVG (MPEG4 video) group compared to that in the Traumaplatform Study Collaborative (DICOM viewer) group (75 and 43%, respectively; P < 0.001). The median observer satisfaction with the online evaluation was seven (range, 0-10) using MPEG4 video compared to six (range, 1-9) using DICOM viewer (P = 0.11). The interobserver reliability for recognition of fracture characteristics in complex tibial plateau fractures was higher for the evaluation using MPEG4 video. In conclusion, observer participation and interobserver reliability for the characterization of tibial plateau fractures was greater with MPEG4 videos than with a standard DICOM viewer, while there was no difference in observer satisfaction. Future reliability studies should account for the method of delivering images.
Corrosion Monitors for Embedded Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robinson, Alex L.; Pfeifer, Kent B.; Casias, Adrian L.
2017-05-01
We have developed and characterized novel in-situ corrosion sensors to monitor and quantify the corrosive potential and history of localized environments. Embedded corrosion sensors can provide information to aid health assessments of internal electrical components including connectors, microelectronics, wires, and other susceptible parts. When combined with other data (e.g. temperature and humidity), theory, and computational simulation, the reliability of monitored systems can be predicted with higher fidelity.
Operating Experience and Reliability Improvements on the 5 kW CW Klystron at Jefferson Lab
NASA Astrophysics Data System (ADS)
Nelson, R.; Holben, S.
1997-05-01
With substantial operating hours on the RF system, considerable information on reliability of the 5 kW CW klystrons has been obtained. High early failure rates led to examination of the operating conditions and failure modes. Internal ceramic contamination caused premature failure of gun potting material and ultimate tube demise through arcing or ceramic fracture. A planned course of repotting and reconditioning of approximately 300 klystrons, plus careful attention to operating conditions and periodic analysis of operational data, has substantially reduced the failure rate. It is anticipated that implementation of planned supplemental monitoring systems for the klystrons will allow most catastrophic failures to be avoided. By predicting end of life, tubes can be changed out before they fail, thus minimizing unplanned downtime. Initial tests have also been conducted on this same klystron operated at higher voltages with resultant higher output power. The outcome of these tests will provide information to be considered for future upgrades to the accelerator.
Affordable Launch Services using the Sport Orbit Transfer System
NASA Astrophysics Data System (ADS)
Goldstein, D. J.
2002-01-01
Despite many advances in small satellite technology, a low-cost, reliable method is needed to place spacecraft in their de- sired orbits. AeroAstro has developed the Small Payload ORbit Transfer (SPORTTM) system to provide a flexible low-cost orbit transfer capability, enabling small payloads to use low-cost secondary launch opportunities and still reach their desired final orbits. This capability allows small payloads to effectively use a wider variety of launch opportunities, including nu- merous under-utilized GTO slots. Its use, in conjunction with growing opportunities for secondary launches, enable in- creased access to space using proven technologies and highly reliable launch vehicles such as the Ariane family and the Starsem launcher. SPORT uses a suite of innovative technologies that are packaged in a simple, reliable, modular system. The command, control and data handling of SPORT is provided by the AeroAstro BitsyTM core electronics module. The Bitsy module also provides power regulation for the batteries and optional solar arrays. The primary orbital maneuvering capability is provided by a nitrous oxide monopropellant propulsion system. This system exploits the unique features of nitrous oxide, which in- clude self-pressurization, good performance, and safe handling, to provide a light-weight, low-cost and reliable propulsion capability. When transferring from a higher energy orbit to a lower energy orbit (i.e. GTO to LEO), SPORT uses aerobraking technol- ogy. After using the propulsion system to lower the orbit perigee, the aerobrake gradually slows SPORT via atmospheric drag. After the orbit apogee is reduced to the target level, an apogee burn raises the perigee and ends the aerobraking. At the conclusion of the orbit transfer maneuver, either the aerobrake or SPORT can be shed, as desired by the payload. SPORT uses a simple design for high reliability and a modular architecture for maximum mission flexibility. This paper will discuss the launch system and its application to small satellite launch without increasing risk. It will also discuss relevant issues such as aerobraking operations and radiation issues, as well as existing partnerships and patents for the system.
Solid-State Thyratron Replacement. Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roth, Ian
2017-12-12
Under this SBIR, DTI developed a solid-state switch as an alternative to legacy thyratron equipment. Our Phase II objective was to make a solid-state thyratron replacement that would provide equivalent or better performance, much higher reliability (at least a 20 year lifetime, compared to a thyratron’s two-year lifetime) and would sell for ~3x the cost of a thyratron, or less than $40k. We were successful in building a solid-state switch which could reliably function as a thyratron replacement. The unit was designed to directly replace the thyratrons currently being used at SLAC’s Linac Coherent Light Source (LCLS), and was builtmore » in a tank that was small enough to fit into the existing thyratron cabinet, providing a true form-fit-function replacement path. We tested the switch at the full operating specifications: 48 kV, 6.3 kA, and 1 µs risetime. We also demonstrated a peak-to-peak pulse jitter of 1.5 ns, which is five times shorter than is typical for thyratrons. This lower jitter would improve the performance of the LCLS beam. The predicted reliability is more than 80 years, which is 40 times greater than a thyratron.« less
Serial Back-Plane Technologies in Advanced Avionics Architectures
NASA Technical Reports Server (NTRS)
Varnavas, Kosta
2005-01-01
Current back plane technologies such as VME, and current personal computer back planes such as PCI, are shared bus systems that can exhibit nondeterministic latencies. This means a card can take control of the bus and use resources indefinitely affecting the ability of other cards in the back plane to acquire the bus. This provides a real hit on the reliability of the system. Additionally, these parallel busses only have bandwidths in the 100s of megahertz range and EMI and noise effects get worse the higher the bandwidth goes. To provide scalable, fault-tolerant, advanced computing systems, more applicable to today s connected computing environment and to better meet the needs of future requirements for advanced space instruments and vehicles, serial back-plane technologies should be implemented in advanced avionics architectures. Serial backplane technologies eliminate the problem of one card getting the bus and never relinquishing it, or one minor problem on the backplane bringing the whole system down. Being serial instead of parallel improves the reliability by reducing many of the signal integrity issues associated with parallel back planes and thus significantly improves reliability. The increased speeds associated with a serial backplane are an added bonus.
Reliable vision-guided grasping
NASA Technical Reports Server (NTRS)
Nicewarner, Keith E.; Kelley, Robert B.
1992-01-01
Automated assembly of truss structures in space requires vision-guided servoing for grasping a strut when its position and orientation are uncertain. This paper presents a methodology for efficient and robust vision-guided robot grasping alignment. The vision-guided grasping problem is related to vision-guided 'docking' problems. It differs from other hand-in-eye visual servoing problems, such as tracking, in that the distance from the target is a relevant servo parameter. The methodology described in this paper is hierarchy of levels in which the vision/robot interface is decreasingly 'intelligent,' and increasingly fast. Speed is achieved primarily by information reduction. This reduction exploits the use of region-of-interest windows in the image plane and feature motion prediction. These reductions invariably require stringent assumptions about the image. Therefore, at a higher level, these assumptions are verified using slower, more reliable methods. This hierarchy provides for robust error recovery in that when a lower-level routine fails, the next-higher routine will be called and so on. A working system is described which visually aligns a robot to grasp a cylindrical strut. The system uses a single camera mounted on the end effector of a robot and requires only crude calibration parameters. The grasping procedure is fast and reliable, with a multi-level error recovery system.
Tutorial: Performance and reliability in redundant disk arrays
NASA Technical Reports Server (NTRS)
Gibson, Garth A.
1993-01-01
A disk array is a collection of physically small magnetic disks that is packaged as a single unit but operates in parallel. Disk arrays capitalize on the availability of small-diameter disks from a price-competitive market to provide the cost, volume, and capacity of current disk systems but many times their performance. Unfortunately, relative to current disk systems, the larger number of components in disk arrays leads to higher rates of failure. To tolerate failures, redundant disk arrays devote a fraction of their capacity to an encoding of their information. This redundant information enables the contents of a failed disk to be recovered from the contents of non-failed disks. The simplest and least expensive encoding for this redundancy, known as N+1 parity is highlighted. In addition to compensating for the higher failure rates of disk arrays, redundancy allows highly reliable secondary storage systems to be built much more cost-effectively than is now achieved in conventional duplicated disks. Disk arrays that combine redundancy with the parallelism of many small-diameter disks are often called Redundant Arrays of Inexpensive Disks (RAID). This combination promises improvements to both the performance and the reliability of secondary storage. For example, IBM's premier disk product, the IBM 3390, is compared to a redundant disk array constructed of 84 IBM 0661 3 1/2-inch disks. The redundant disk array has comparable or superior values for each of the metrics given and appears likely to cost less. In the first section of this tutorial, I explain how disk arrays exploit the emergence of high performance, small magnetic disks to provide cost-effective disk parallelism that combats the access and transfer gap problems. The flexibility of disk-array configurations benefits manufacturer and consumer alike. In contrast, I describe in this tutorial's second half how parallelism, achieved through increasing numbers of components, causes overall failure rates to rise. Redundant disk arrays overcome this threat to data reliability by ensuring that data remains available during and after component failures.
A high performance totally ordered multicast protocol
NASA Technical Reports Server (NTRS)
Montgomery, Todd; Whetten, Brian; Kaplan, Simon
1995-01-01
This paper presents the Reliable Multicast Protocol (RMP). RMP provides a totally ordered, reliable, atomic multicast service on top of an unreliable multicast datagram service such as IP Multicasting. RMP is fully and symmetrically distributed so that no site bears un undue portion of the communication load. RMP provides a wide range of guarantees, from unreliable delivery to totally ordered delivery, to K-resilient, majority resilient, and totally resilient atomic delivery. These QoS guarantees are selectable on a per packet basis. RMP provides many communication options, including virtual synchrony, a publisher/subscriber model of message delivery, an implicit naming service, mutually exclusive handlers for messages, and mutually exclusive locks. It has commonly been held that a large performance penalty must be paid in order to implement total ordering -- RMP discounts this. On SparcStation 10's on a 1250 KB/sec Ethernet, RMP provides totally ordered packet delivery to one destination at 842 KB/sec throughput and with 3.1 ms packet latency. The performance stays roughly constant independent of the number of destinations. For two or more destinations on a LAN, RMP provides higher throughput than any protocol that does not use multicast or broadcast.
NASA Astrophysics Data System (ADS)
Norouzi, H.; Bah, A.; Prakash, S.; Nouri, N.; Blake, R.
2017-12-01
A great percentage of the world's population reside in urban areas that are exposed to the threats of global and regional climate changes and associated extreme weather events. Among them, urban heat islands have significant health and economic impacts due to higher thermal gradients of impermeable surfaces in urban regions compared to their surrounding rural areas. Therefore, accurate characterization of the surface energy balance in urban regions are required to predict these extreme events. High spatial resolution Land surface temperature (LST) in the scale of street level in the cities can provide wealth of information to study surface energy balance and eventually providing a reliable heat index. In this study, we estimate high-resolution LST maps using combination of LandSat 8 and infrared based satellite products such as Moderate Resolution Imaging Spectroradiometer (MODIS) and newly launched Geostationary Operational Environmental Satellite-R Series (GOES-R). Landsat 8 provides higher spatial resolution (30 m) estimates of skin temperature every 16 days. However, MODIS and GOES-R have lower spatial resolution (1km and 4km respectively) with much higher temporal resolution. Several statistical downscaling methods were investigated to provide high spatiotemporal LST maps in urban regions. The results reveal that statistical methods such as Principal Component Analysis (PCA) can provide reliable estimations of LST downscaling with 2K accuracy. Other methods also were tried including aggregating (up-scaling) the high-resolution data to a coarse one to examine the limitations and to build the model. Additionally, we deployed flux towers over distinct materials such as concrete, asphalt, and rooftops in New York City to monitor the sensible and latent heat fluxes through eddy covariance method. To account for the incoming and outgoing radiation, a 4-component radiometer is used that can observe both incoming and outgoing longwave and shortwave radiation. This enables us to accurately build the relationship between LST, air temperature, and the heat index in the future.
Retention Strength of Conical Welding Caps for Fixed Implant-Supported Prostheses.
Nardi, Diego; Degidi, Marco; Sighinolfi, Gianluca; Tebbel, Florian; Marchetti, Claudio
This study evaluated the retention strength of welding caps for Ankylos standard abutments using a pull-out test. Each sample consisted of an implant abutment and its welding cap. The tests were performed with a Zwick Roell testing machine with a 1-kN load cell. The retention strength of the welding caps increased with higher abutment diameters and higher head heights and was comparable or superior to the values reported in the literature for the temporary cements used in implant dentistry. Welding caps provide a reliable connection between an abutment and a fixed prosthesis without the use of cement.
NASA Technical Reports Server (NTRS)
Studor, George
2010-01-01
The presentation reviews what is meant by the term 'fly-by-wireless', common problems and motivation, provides recent examples, and examines NASA's future and basis for collaboration. The vision is to minimize cables and connectors and increase functionality across the aerospace industry by providing reliable, lower cost, modular, and higher performance alternatives to wired data connectivity to benefit the entire vehicle/program life-cycle. Focus areas are system engineering and integration methods to reduce cables and connectors, vehicle provisions for modularity and accessibility, and a 'tool box' of alternatives to wired connectivity.
Service quality, patient satisfaction and loyalty in the Bangladesh healthcare sector.
Ahmed, Selim; Tarique, Kazi Md; Arif, Ishtiaque
2017-06-12
Purpose The purpose of this paper is to investigate service quality, patient satisfaction and loyalty in Bangladesh's healthcare sector. It identifies healthcare quality conformance, patient satisfaction and loyalty based on demographics such as gender, age and marital status. It examines the differences between public and private healthcare sectors regarding service quality, patient satisfaction and loyalty. Design/methodology/approach The authors distributed 450 self-administered questionnaires to hospital patients resulting in 204 useful responses (45.3 per cent response rate). Data were analysed based on reliability analysis, exploratory factor analysis, independent samples t-tests, ANOVA and discriminant analysis using SPSS version 23. Findings Findings indicate that single patients perceive tangibles, reliability, empathy and loyalty higher compared to married patients. Young patients (⩽20 years) have a higher tangibles, empathy and loyalty scores compared to other age groups. The authors observed that private hospital patients perceive healthcare service quality performance higher compared to patients in public hospitals. Research limitations/implications The authors focussed solely on the Bangladesh health sector, so the results might not be applicable to other countries. Originality/value The findings provide guidelines for enhancing service quality, patient satisfaction and loyalty in the Bangladesh healthcare sector and other countries.
Regulation of transmission line capacity and reliability in electric networks
NASA Astrophysics Data System (ADS)
Celebi, Metin
This thesis is composed of two essays that analyze the incentives and optimal regulation of a monopolist line owner in providing capacity and reliability. Similar analyses in the economic literature resulted in under-investment by an unregulated line owner when line reliability was treated as an exogenous variable. However, reliability should be chosen on the basis of economic principles as well, taking into account not only engineering principles but also the preferences of electricity users. When reliability is treated as a choice variable, both over- and under-investment by the line owner becomes possible. The result depends on the cross-cost elasticity of line construction and on the interval in which the optimal choices of capacity take place. We present some sufficient conditions that lead to definite results about the incentives of the line owner. We also characterize the optimal regulation of the line owner under incomplete information. Our analysis shows that the existence of a line is justified for the social planner when the reliability of other lines on the network is not too high, or when the marginal cost of generation at the expensive generating plant is high. The expectation of higher demand in the future makes the regulator less likely to build the line if it will be congested and reliability of other lines is high enough. It is always optimal to have a congested line under complete information, but not necessarily under incomplete information.
Definition and Proposed Realization of the International Height Reference System (IHRS)
NASA Astrophysics Data System (ADS)
Ihde, Johannes; Sánchez, Laura; Barzaghi, Riccardo; Drewes, Hermann; Foerste, Christoph; Gruber, Thomas; Liebsch, Gunter; Marti, Urs; Pail, Roland; Sideris, Michael
2017-05-01
Studying, understanding and modelling global change require geodetic reference frames with an order of accuracy higher than the magnitude of the effects to be actually studied and with high consistency and reliability worldwide. The International Association of Geodesy, taking care of providing a precise geodetic infrastructure for monitoring the Earth system, promotes the implementation of an integrated global geodetic reference frame that provides a reliable frame for consistent analysis and modelling of global phenomena and processes affecting the Earth's gravity field, the Earth's surface geometry and the Earth's rotation. The definition, realization, maintenance and wide utilization of the International Terrestrial Reference System guarantee a globally unified geometric reference frame with an accuracy at the millimetre level. An equivalent high-precision global physical reference frame that supports the reliable description of changes in the Earth's gravity field (such as sea level variations, mass displacements, processes associated with geophysical fluids) is missing. This paper addresses the theoretical foundations supporting the implementation of such a physical reference surface in terms of an International Height Reference System and provides guidance for the coming activities required for the practical and sustainable realization of this system. Based on conceptual approaches of physical geodesy, the requirements for a unified global height reference system are derived. In accordance with the practice, its realization as the International Height Reference Frame is designed. Further steps for the implementation are also proposed.
Bearing Procurement Analysis Method by Total Cost of Ownership Analysis and Reliability Prediction
NASA Astrophysics Data System (ADS)
Trusaji, Wildan; Akbar, Muhammad; Sukoyo; Irianto, Dradjad
2018-03-01
In making bearing procurement analysis, price and its reliability must be considered as decision criteria, since price determines the direct cost as acquisition cost and reliability of bearing determine the indirect cost such as maintenance cost. Despite the indirect cost is hard to identify and measured, it has high contribution to overall cost that will be incurred. So, the indirect cost of reliability must be considered when making bearing procurement analysis. This paper tries to explain bearing evaluation method with the total cost of ownership analysis to consider price and maintenance cost as decision criteria. Furthermore, since there is a lack of failure data when bearing evaluation phase is conducted, reliability prediction method is used to predict bearing reliability from its dynamic load rating parameter. With this method, bearing with a higher price but has higher reliability is preferable for long-term planning. But for short-term planning the cheaper one but has lower reliability is preferable. This contextuality can give rise to conflict between stakeholders. Thus, the planning horizon needs to be agreed by all stakeholder before making a procurement decision.
Reliability Analysis and Modeling of ZigBee Networks
NASA Astrophysics Data System (ADS)
Lin, Cheng-Min
The architecture of ZigBee networks focuses on developing low-cost, low-speed ubiquitous communication between devices. The ZigBee technique is based on IEEE 802.15.4, which specifies the physical layer and medium access control (MAC) for a low rate wireless personal area network (LR-WPAN). Currently, numerous wireless sensor networks have adapted the ZigBee open standard to develop various services to promote improved communication quality in our daily lives. The problem of system and network reliability in providing stable services has become more important because these services will be stopped if the system and network reliability is unstable. The ZigBee standard has three kinds of networks; star, tree and mesh. The paper models the ZigBee protocol stack from the physical layer to the application layer and analyzes these layer reliability and mean time to failure (MTTF). Channel resource usage, device role, network topology and application objects are used to evaluate reliability in the physical, medium access control, network, and application layers, respectively. In the star or tree networks, a series system and the reliability block diagram (RBD) technique can be used to solve their reliability problem. However, a division technology is applied here to overcome the problem because the network complexity is higher than that of the others. A mesh network using division technology is classified into several non-reducible series systems and edge parallel systems. Hence, the reliability of mesh networks is easily solved using series-parallel systems through our proposed scheme. The numerical results demonstrate that the reliability will increase for mesh networks when the number of edges in parallel systems increases while the reliability quickly drops when the number of edges and the number of nodes increase for all three networks. More use of resources is another factor impact on reliability decreasing. However, lower network reliability will occur due to network complexity, more resource usage and complex object relationship.
Banks, Merrilyn; Hannan-Jones, Mary; Ross, Lynda; Buckley, Ann; Ellick, Jennifer; Young, Adrienne
2017-04-01
To develop and test the reliability of a Meal Quality Audit Tool (MQAT) to audit the quality of hospital meals to assist food service managers and dietitians in identifying areas for improvement. The MQAT was developed using expert opinion and was modified over time with extensive use and feedback. A phased approach was used to assess content validity and test reliability: (i) trial with 60 dietetic students, (ii) trial with 12 food service dietitians in practice and (iii) interrater reliability study. Phases 1 and 2 confirmed content validity and informed minor revision of scoring, language and formatting of the MQAT. To assess reliability of the final MQAT, eight separate meal quality audits of five identical meals were conducted over several weeks in the hospital setting. Each audit comprised an 'expert' team and four 'test' teams (dietitians, food services and ward staff). Interrater reliability was determined using intra-class correlation analysis. There was statistically significant interrater reliability for dimensions of Temperature and Accuracy (P < 0.001) but not for Appearance or Sensory. Composition of the 'test' team appeared to influence results for Appearance and Sensory, with food service-led teams scoring higher on these dimensions. 'Test' teams reported that MQAT was clear and easy to use. MQAT was found to be reliable for Temperature and Accuracy domains, with further work required to improve the reliability of the Appearance and Sensory dimensions. The systematic use of the tool, used in conjunction with patient satisfaction, could provide pertinent and useful information regarding the quality of food services and areas for improvement. © 2017 Dietitians Association of Australia.
Physics-based process modeling, reliability prediction, and design guidelines for flip-chip devices
NASA Astrophysics Data System (ADS)
Michaelides, Stylianos
Flip Chip on Board (FCOB) and Chip-Scale Packages (CSPs) are relatively new technologies that are being increasingly used in the electronic packaging industry. Compared to the more widely used face-up wirebonding and TAB technologies, flip-chips and most CSPs provide the shortest possible leads, lower inductance, higher frequency, better noise control, higher density, greater input/output (I/O), smaller device footprint and lower profile. However, due to the short history and due to the introduction of several new electronic materials, designs, and processing conditions, very limited work has been done to understand the role of material, geometry, and processing parameters on the reliability of flip-chip devices. Also, with the ever-increasing complexity of semiconductor packages and with the continued reduction in time to market, it is too costly to wait until the later stages of design and testing to discover that the reliability is not satisfactory. The objective of the research is to develop integrated process-reliability models that will take into consideration the mechanics of assembly processes to be able to determine the reliability of face-down devices under thermal cycling and long-term temperature dwelling. The models incorporate the time and temperature-dependent constitutive behavior of various materials in the assembly to be able to predict failure modes such as die cracking and solder cracking. In addition, the models account for process-induced defects and macro-micro features of the assembly. Creep-fatigue and continuum-damage mechanics models for the solder interconnects and fracture-mechanics models for the die have been used to determine the reliability of the devices. The results predicted by the models have been successfully validated against experimental data. The validated models have been used to develop qualification and test procedures for implantable medical devices. In addition, the research has helped develop innovative face-down devices without the underfill, based on the thorough understanding of the failure modes. Also, practical design guidelines for material, geometry and process parameters for reliable flip-chip devices have been developed.
Radiographic measurement reliability of lumbar lordosis in ankylosing spondylitis.
Lee, Jung Sub; Goh, Tae Sik; Park, Shi Hwan; Lee, Hong Seok; Suh, Kuen Tak
2013-04-01
Intraobserver and interobserver reliabilities of the several different methods to measure lumbar lordosis have been reported. However, it has not been studied sofar in patients with ankylosing spondylitis (AS). We evaluated the inter and intraobserver reliabilities of six specific measures of global lumbar lordosis in patients with AS. Ninety-one consecutive patients with AS who met the most recently modified New York criteria were enrolled and underwent anteroposterior and lateral radiographs of whole spine. The radiographs were divided into non-ankylosis (no bony bridge in the lumbar spine), incomplete ankylosis (lumbar spines were partially connected by bony bridge) and complete ankylosis groups to evaluate the reliability of the Cobb L1-S1, Cobb L1-L5, centroid, posterior tangent L1-S1, posterior tangent L1-L5, and TRALL methods. The radiographs were composed of 39 non-ankylosis, 27 incomplete ankylosis and 25 complete ankylosis. Intra- and inter-class correlation coefficients (ICCs) of all six methods were generally high. The ICCs were all ≥0.77 (excellent) for the six radiographic methods in the combined group. However, a comparison of the ICCs, 95 % confidence intervals and mean absolute difference (MAD) between groups with varying degrees of ankylosis showed that the reliability of the lordosis measurements decreased in proportion to the severity of ankylosis. The Cobb L1-S1, Cobb L1-L5 and posterior tangent L1-S1 method demonstrated higher ICCs for both inter and intraobserver comparisons and the other methods showed lower ICCs in all groups. The intraobserver MAD was similar in the Cobb L1-S1 and Cobb L1-L5 (2.7°-4.3°), but the other methods showed higher intraobserver MAD. Interobserver MAD of Cobb L1-L5 only showed low in all group. These results are the first to provide a reliability analysis of different global lumbar lordosis measurement methods in AS. The findings in this study demonstrated that the Cobb L1-L5 method is reliable for measuring the global lumbar lordosis in AS.
Effects of imperfect automation on decision making in a simulated command and control task.
Rovira, Ericka; McGarry, Kathleen; Parasuraman, Raja
2007-02-01
Effects of four types of automation support and two levels of automation reliability were examined. The objective was to examine the differential impact of information and decision automation and to investigate the costs of automation unreliability. Research has shown that imperfect automation can lead to differential effects of stages and levels of automation on human performance. Eighteen participants performed a "sensor to shooter" targeting simulation of command and control. Dependent variables included accuracy and response time of target engagement decisions, secondary task performance, and subjective ratings of mental work-load, trust, and self-confidence. Compared with manual performance, reliable automation significantly reduced decision times. Unreliable automation led to greater cost in decision-making accuracy under the higher automation reliability condition for three different forms of decision automation relative to information automation. At low automation reliability, however, there was a cost in performance for both information and decision automation. The results are consistent with a model of human-automation interaction that requires evaluation of the different stages of information processing to which automation support can be applied. If fully reliable decision automation cannot be guaranteed, designers should provide users with information automation support or other tools that allow for inspection and analysis of raw data.
[Analysis of reliability and validity of the Chinese Version of Dizziness Handicap Inventory (DHI)].
Zhang, Yi; Liu, Bo; Wang, Yongjun; Zhou, Yun; Wang, Rui; Gong, Jing; Peng, Xiaoxia
2015-09-01
To investigate the reliability and validity of the Chinese Version of Dizziness Handicap Inventory (DHI). Cross-cultural adaptation of health-related quality of life measures was used for translating the DHI to Chinese version. The DHI contains 7 physical, 9 emotional, and 9 functional questions.The patients scored the DHI straightforward. Then the scores of the total scale and each subscales were calculated and evaluated.Three hundred and sixty-six dizzy patients,116 males and 250 females, aged from 14 to 79 years, were included in the research and finished the questionnaire of the evaluation.SPSS 13.0 was used for statistical analysis. Reliability: Cronbach α values for the total and subscale of DHI were 0.751-0.912. The reliability coefficients were 0.877-0.921 (P < 0.001). the correlation coefficients between the total scale and three subscale were 0.815-0.934 (P < 0.001). The correlation coefficients of the scores internal the subscale were higher than between the other subscale (r = 0.446-0.781). Common factor analysis provides 5 factors. The cumulative variance ratio was 54.5%. The component of each item was over 0.4. Chinese version of DHI has good reliability and validity, which can be used to evaluate the dizzy patients.
Ionization of NO at high temperature
NASA Technical Reports Server (NTRS)
Hansen, C. Frederick
1991-01-01
Space vehicles flying through the atmosphere at high speed are known to excite a complex set of chemical reactions in the atmospheric gases, ranging from simple vibrational excitation to dissociation, atom exchange, electronic excitation, ionization, and charge exchange. Simple arguments are developed for the temperature dependence of the reactions leading to ionization of NO, including the effect of vibrational electronic thermal nonequilibrium. NO ionization is the most important source of electrons at intermediate temperatures and at higher temperatures provides the trigger electrons that ionize atoms. Based on these arguments, recommendations are made for formulae which fit observed experimental results, and which include a dependence on both a heavy particle temperature and different vibration electron temperatures. In addition, these expressions will presumably provide the most reliable extrapolation of experimental results to much higher temperatures.
Universal first-order reliability concept applied to semistatic structures
NASA Technical Reports Server (NTRS)
Verderaime, V.
1994-01-01
A reliability design concept was developed for semistatic structures which combines the prevailing deterministic method with the first-order reliability method. The proposed method surmounts deterministic deficiencies in providing uniformly reliable structures and improved safety audits. It supports risk analyses and reliability selection criterion. The method provides a reliability design factor derived from the reliability criterion which is analogous to the current safety factor for sizing structures and verifying reliability response. The universal first-order reliability method should also be applicable for air and surface vehicles semistatic structures.
Universal first-order reliability concept applied to semistatic structures
NASA Astrophysics Data System (ADS)
Verderaime, V.
1994-07-01
A reliability design concept was developed for semistatic structures which combines the prevailing deterministic method with the first-order reliability method. The proposed method surmounts deterministic deficiencies in providing uniformly reliable structures and improved safety audits. It supports risk analyses and reliability selection criterion. The method provides a reliability design factor derived from the reliability criterion which is analogous to the current safety factor for sizing structures and verifying reliability response. The universal first-order reliability method should also be applicable for air and surface vehicles semistatic structures.
Yadegarfar, Ghasem; Alinia, Tahereh; Hosseini, Reihane; Hassannejad, Razieh; Fayaz, Mahsa; Sanati, Javad; Sanati, Kave; Harandi, Jalal; Hajnoorozali, Vahid; Baghi, Mahmood-Reza; Mirzavand, Enayat; Majeed, Azeem
2013-02-01
To assess the reliability and validity of the Farsi version of the effort-reward imbalance questionnaire (F-ERIQ) and to examine the responsiveness of the tool to changes over time. A longitudinal study was carried out among 227 male employees of Iran Polyacryl Corporation. The F-ERIQ was developed through a forward-backward translation process that includes three scales of effort, reward and over-commitment (OC). Reliability and internal consistency of the F-ERIQ were assessed by split-half and Cronbach's alpha coefficients. Confirmatory factor analysis, convergent and discriminant validity were conducted to evaluate construct validity. Depressive mood was used as an indicator for exploring criterion validity. The variations in mean scores over time for scales were regarded as measures of the responsiveness to changes. Baseline split-half correlations for effort, reward and OC were 0.53, 0.85 and 0.65, respectively; Cronbach's alpha coefficients improved from 0.61 to 0.70 for effort, 0.85 to 0.88 for reward and 0.67 to 0.72 for OC. All of item-total correlations were higher than 0.23 and item-scales correlations were higher than 0.4. Although Values of Goodness of Fit Index and Adjusted GFI were higher than 0.9 and Root Mean Square Error of Approximation, Root Mean Square Residual and Standardized RMR were lower than 0.05, confirmatory factor analysis only confirmed the construct of the effort and OC. People with higher job stress were at higher risk of depressive mood (at least 3 times more). Overall, the mean score of effort, OC and ERI increase, and the figures decrease for reward among people who experience changes. These findings provide evidence that the F-ERIQ is a reliable and valid instrument for assessing psychosocial stress at work among Farsi-speaking male employees. We propose that F-ERIQ be further evaluated across a variety of jobs and industries.
Skiles, Martha Priedeman; Cunningham, Marc; Inglis, Andrew; Wilkes, Becky; Hatch, Ben; Bock, Ariella; Barden-O'Fallon, Janine
2015-03-01
Previous studies have identified positive relationships between geographic proximity to family planning services and contraceptive use, but have not accounted for the effect of contraceptive supply reliability or the diminishing influence of facility access with increasing distance. Kernel density estimation was used to geographically link Malawi women's use of injectable contraceptives and demand for birth spacing or limiting, as drawn from the 2010 Demographic and Health Survey, with contraceptive logistics data from family planning service delivery points. Linear probability models were run to identify associations between access to injectable services-measured by distance alone and by distance combined with supply reliability-and injectable use and family planning demand among rural and urban populations. Access to services was an important predictor of injectable use. The probability of injectable use among rural women with the most access by both measures was 7‒8 percentage points higher than among rural dwellers with the least access. The probability of wanting to space or limit births among urban women who had access to the most reliable supplies was 18 percentage points higher than among their counterparts with the least access. Product availability in the local service environment plays a critical role in women's demand for and use of contraceptive methods. Use of kernel density estimation in creating facility service environments provides a refined approach to linking women with services and accounts for both distance to facilities and supply reliability. Urban and rural differences should be considered when seeking to improve contraceptive access.
Heyman, Richard E; Slep, Amy M Smith; Foran, Heather M
2015-03-01
Nuanced, multifaceted, and content valid diagnostic criteria for intimate partner violence (IPV) have been created and can be used reliably in the field even by those with little-to-no clinical training/background. The use of such criteria such as these would likely lead to more reliable decision making in the field and more consistency across studies. Further, interrater agreement was higher than that usually reported for individual mental disorders. This paper will provide an overview of (a) IPV's scope and impact; (b) the reliable and valid diagnostic criteria that have been used and the adaptation of these criteria inserted in the latest Diagnostic and Statistical Manual of Mental Disorders (DSM) and another adaptation proposed for the forthcoming International Statistical Classification of Diseases and Related Health Problems (ICD); (c) suggestions for screening of IPV in primary care settings; (d) interventions for IPV; and (e) suggested steps toward globally accepted programs. © 2015 Family Process Institute.
Status and Needs of Power Electronics for Photovoltaic Inverters: Summary Document
NASA Astrophysics Data System (ADS)
West, R.; Mauch, K.; Qin, Y. C.; Mohan, N.; Bonn, R.
2002-05-01
Photovoltaic inverters are the most mature of any DER inverter, and their mean time to first failure (MTFF) is about five years. This is an unacceptable MTFF and will inhibit the rapid expansion of PV. With all DER technologies, (solar, wind, fuel cells, and microturbines) the inverter is still an immature product that will result in reliability problems in fielded systems. The increasing need for all of these technologies to have a reliable inverter provides a unique opportunity to address these needs with focused R&D development projects. The requirements for these inverters are so similar that modular designs with universal features are obviously the best solution for a 'next generation' inverter. A 'next generation' inverter will have improved performance, higher reliability, and improved profitability. Sandia National Laboratories has estimated that the development of a 'next generation' inverter could require approximately 20 man-years of work over an 18- to 24-month time frame, and that a government-industry partnership will greatly improve the chances of success.
Liu, Zifeng; Yuan, Lianxiong; Huang, Yixiang; Zhang, Lingling; Luo, Futian
2016-01-01
Objective We aimed to develop a questionnaire for quantitative evaluation of the autonomy of public hospitals in China. Method An extensive literature review was conducted to select possible items for inclusion in the questionnaire, which was then reviewed by 5 experts. After a two-round Delphi method, we distributed the questionnaire to 404 secondary and tertiary hospitals in Guangdong Province, China, and 379 completed questionnaires were collected. The final questionnaire was then developed on the basis of the results of exploratory and confirmatory factor analysis. Results Analysis suggested that all internal consistency reliabilities exceeded the minimum reliability standard of 0.70 for the α coefficient. The overall scale coefficient was 0.87, and 6 subscale coefficients were 0.92 (strategic management), 0.81 (budget and expenditure), 0.85 (financing), 0.75 (financing, medical management), 0.86 (human resources) and 0.86 (accountability). Correlation coefficients between and among items and their hypothesised subscales were higher than those with other subscales. The value of average variance extracted (AVE) was higher than 0.5, the value of construct reliability (CR) was higher than 0.7, and the square roots of the AVE of each subscale were larger than the correlation of the specific subscale with the other subscales, supporting the convergent and discriminant validity of the Chinese version of the Hospital Autonomy Questionnaire (CVHAQ). The model fit indices were all acceptable: χ2/df=1.73, Goodness of Fit Index (GFI) = 0.93, Adjusted Goodness of Fit Index (AGFI) = 0.91, Non-Normed Fit Index (NNFI) = 0.96, Comparative Fit Index (CFI) = 0.97, Root Mean Square Error of Approximation (RMSEA) = 0.04, Standardised Root Mean Square Residual (SRMR) = 0.07. Conclusions This study demonstrated the reliability and validity of a CVHAQ and provides a quantitative method for the assessment of hospital autonomy. PMID:26911587
Hilbert, Anja; de Zwaan, Martina; Braehler, Elmar; Kersting, Anette
2016-01-01
The Dutch Eating Behavior Questionnaire is an internationally widely used instrument assessing different eating styles that may contribute to weight gain and overweight: emotional eating, external eating, and restraint. This study aimed to evaluate the psychometric properties of the 30-item German version of the DEBQ including its measurement invariance across gender, age, and BMI-status in a representative German population sample. Furthermore, we examined the distribution of eating styles in the general population and provide population-based norms for DEBQ scales. A representative sample of the German general population (N = 2513, age ≥ 14 years) was assessed with the German version of the DEBQ along with information on sociodemographic characteristics and body weight and height. The German version of the DEQB demonstrates good item characteristics and reliability (restraint: α = .92, emotional eating: α = .94, external eating: α = .89). The 3-factor structure of the DEBQ could be replicated in exploratory and confirmatory factor analyses and results of multi-group confirmatory factor analyses supported its metric and scalar measurement invariance across gender, age, and BMI-status. External eating was the most prevalent eating style in the German general population. Women scored higher on emotional and restrained eating scales than men, and overweight individuals scored higher in all three eating styles compared to normal weight individuals. Small differences across age were found for external eating. Norms were provided according to gender, age, and BMI-status. Our findings suggest that the German version of the DEBQ has good reliability and construct validity, and is suitable to reliably measure eating styles across age, gender, and BMI-status. Furthermore, the results demonstrate a considerable variation of eating styles across gender and BMI-status. PMID:27656879
Nagl, Michaela; Hilbert, Anja; de Zwaan, Martina; Braehler, Elmar; Kersting, Anette
The Dutch Eating Behavior Questionnaire is an internationally widely used instrument assessing different eating styles that may contribute to weight gain and overweight: emotional eating, external eating, and restraint. This study aimed to evaluate the psychometric properties of the 30-item German version of the DEBQ including its measurement invariance across gender, age, and BMI-status in a representative German population sample. Furthermore, we examined the distribution of eating styles in the general population and provide population-based norms for DEBQ scales. A representative sample of the German general population (N = 2513, age ≥ 14 years) was assessed with the German version of the DEBQ along with information on sociodemographic characteristics and body weight and height. The German version of the DEQB demonstrates good item characteristics and reliability (restraint: α = .92, emotional eating: α = .94, external eating: α = .89). The 3-factor structure of the DEBQ could be replicated in exploratory and confirmatory factor analyses and results of multi-group confirmatory factor analyses supported its metric and scalar measurement invariance across gender, age, and BMI-status. External eating was the most prevalent eating style in the German general population. Women scored higher on emotional and restrained eating scales than men, and overweight individuals scored higher in all three eating styles compared to normal weight individuals. Small differences across age were found for external eating. Norms were provided according to gender, age, and BMI-status. Our findings suggest that the German version of the DEBQ has good reliability and construct validity, and is suitable to reliably measure eating styles across age, gender, and BMI-status. Furthermore, the results demonstrate a considerable variation of eating styles across gender and BMI-status.
Improving fMRI reliability in presurgical mapping for brain tumours.
Stevens, M Tynan R; Clarke, David B; Stroink, Gerhard; Beyea, Steven D; D'Arcy, Ryan Cn
2016-03-01
Functional MRI (fMRI) is becoming increasingly integrated into clinical practice for presurgical mapping. Current efforts are focused on validating data quality, with reliability being a major factor. In this paper, we demonstrate the utility of a recently developed approach that uses receiver operating characteristic-reliability (ROC-r) to: (1) identify reliable versus unreliable data sets; (2) automatically select processing options to enhance data quality; and (3) automatically select individualised thresholds for activation maps. Presurgical fMRI was conducted in 16 patients undergoing surgical treatment for brain tumours. Within-session test-retest fMRI was conducted, and ROC-reliability of the patient group was compared to a previous healthy control cohort. Individually optimised preprocessing pipelines were determined to improve reliability. Spatial correspondence was assessed by comparing the fMRI results to intraoperative cortical stimulation mapping, in terms of the distance to the nearest active fMRI voxel. The average ROC-r reliability for the patients was 0.58±0.03, as compared to 0.72±0.02 in healthy controls. For the patient group, this increased significantly to 0.65±0.02 by adopting optimised preprocessing pipelines. Co-localisation of the fMRI maps with cortical stimulation was significantly better for more reliable versus less reliable data sets (8.3±0.9 vs 29±3 mm, respectively). We demonstrated ROC-r analysis for identifying reliable fMRI data sets, choosing optimal postprocessing pipelines, and selecting patient-specific thresholds. Data sets with higher reliability also showed closer spatial correspondence to cortical stimulation. ROC-r can thus identify poor fMRI data at time of scanning, allowing for repeat scans when necessary. ROC-r analysis provides optimised and automated fMRI processing for improved presurgical mapping. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Keune, Philipp M; Young, William R; Paraskevopoulos, Ioannis T; Hansen, Sascha; Muenssinger, Jana; Oschmann, Patrick; Müller, Roy
2017-08-15
Balance deficits in multiple sclerosis (MS) are often monitored by means of observer-rated tests. These may provide reliable data, but may also be time-consuming, subject to inter-rater variability, and potentially insensitive to mild fluctuations throughout the clinical course. On the other hand, laboratory assessments are often not available. The Nintendo Wii Balance Board (WBB) may represent a low-cost solution. The purpose of the current study was to examine the methodological quality of WBB data in MS (internal consistency, test-retest reliability), convergent validity with observer-rated tests (Berg Balance Scale, BBS; Timed-Up and Go Test, TUG), and discriminative validity concerning clinical status (Expanded Disability Status Scale, EDSS). Standing balance was assessed with the WBB for 4min in 63 MS patients at two assessment points, four months apart. Additionally, patients were examined with the BBS, TUG and the EDSS. A period of 4min on the WBB provided data characterized by excellent internal consistency and test-retest reliability. Significant correlations between WBB data and results of the BBS and TUG were obtained after merely 2min on the board. An EDSS median-split revealed that higher EDSS values (>3) were associated with significantly increased postural sway on the WBB. WBB measures reflecting postural sway are methodologically robust in MS, involving excellent internal consistency and test-retest reliability. They are also characterized by convergent validity with other considerably lengthier observer-rated balance measures (BBS) and sensitive to broader clinical characteristics (EDSS). The WBB may hence represent an effective, easy-to-use monitoring tool for MS patients in clinical practice. Copyright © 2017 Elsevier B.V. All rights reserved.
Grindem, Hege; Eitzen, Ingrid; Snyder-Mackler, Lynn; Risberg, May Arna
2013-01-01
Background Current methods measuring sports activity after anterior cruciate ligament (ACL) injury are commonly restricted to the most knee-demanding sport, and do not consider participation in multiple sports. We therefore developed an online activity survey to prospectively record monthly participation in all major sports relevant to our patient-group. Objective To assess the reliability, content validity, and concurrent validity of the survey, and evaluate if it provided more complete data on sports participation than a routine activity questionnaire. Methods One hundred and forty-five consecutively included ACL-injured patients were eligible for the reliability study. The retest of the online activity survey was performed two days after the test response had been recorded. A subsample of 88 ACL-reconstructed patients were included in the validity study. The ACL-reconstructed patients completed the online activity survey from the first to the twelfth postoperative month, and a routine activity questionnaire 6 and 12 months postoperatively. Results The online activity survey was highly reliable (κ ranging from 0.81 to 1). It contained all the common sports reported on the routine activity questionnaire. There was substantial agreement between the two methods on return to preinjury main sport (κ = 0.71 and 0.74 at 6 and 12 months postoperatively). The online activity survey revealed that a significantly higher number of patients reported to participate in running, cycling and strength training, and patients reported to participate in a greater number of sports. Conclusion The online activity survey is a highly reliable way of recording detailed changes in sports participation after ACL injury. The findings of this study support the content and concurrent validity of the survey, and suggest that the online activity survey can provide more complete data on sports participation than a routine activity questionnaire. PMID:23645830
NASA Astrophysics Data System (ADS)
Huang, Y.; Kim, H. J.; McCracken, M.; Viswanathan, G.; Pon, F.; Mayer, M.; Zhou, Y. N.
2011-06-01
A 0.3- μm-thick electrolytic Pd layer was plated on 1 μm of electroless Ni on 1 mm-thick polished and roughened Cu substrates with roughness values ( R a) of 0.08 μm and 0.5 μm, respectively. The rough substrates were produced with sand-blasting. Au wire bonding on the Ni/Pd surface was optimized, and the electrical reliability was investigated under a high temperature storage test (HTST) during 800 h at 250°C by measuring the ball bond contact resistance, R c. The average value of R c of optimized ball bonds on the rough substrate was 1.96 mΩ which was about 40.0% higher than that on the smooth substrate. The initial bondability increased for the rougher surface, so that only half of the original ultrasonic level was required, but the reliability was not affected by surface roughness. For both substrate types, HTST caused bond healing, reducing the average R c by about 21% and 27%, respectively. Au diffusion into the Pd layer was observed in scanning transmission electron microscopy/ energy dispersive spectroscopy (STEM-EDS) line-scan analysis after HTST. It is considered that diffusion of Au or interdiffusion between Au and Pd can provide chemically strong bonding during HTST. This is supported by the R c decrease measured as the aging time increased. Cu migration was indicated in the STEM-EDS analysis, but its effect on reliability can be ignored. Au and Pd tend to form a complete solid solution at the interface and can provide reliable interconnection for high temperature (250°C) applications.
Grindem, Hege; Eitzen, Ingrid; Snyder-Mackler, Lynn; Risberg, May Arna
2014-05-01
The current methods measuring sports activity after anterior cruciate ligament (ACL) injury are commonly restricted to the most knee-demanding sports, and do not consider participation in multiple sports. We therefore developed an online activity survey to prospectively record the monthly participation in all major sports relevant to our patient-group. To assess the reliability, content validity and concurrent validity of the survey and to evaluate if it provided more complete data on sports participation than a routine activity questionnaire. 145 consecutively included ACL-injured patients were eligible for the reliability study. The retest of the online activity survey was performed 2 days after the test response had been recorded. A subsample of 88 ACL-reconstructed patients was included in the validity study. The ACL-reconstructed patients completed the online activity survey from the first to the 12th postoperative month, and a routine activity questionnaire 6 and 12 months postoperatively. The online activity survey was highly reliable (κ ranging from 0.81 to 1). It contained all the common sports reported on the routine activity questionnaire. There was a substantial agreement between the two methods on return to preinjury main sport (κ=0.71 and 0.74 at 6 and 12 months postoperatively). The online activity survey revealed that a significantly higher number of patients reported to participate in running, cycling and strength training, and patients reported to participate in a greater number of sports. The online activity survey is a highly reliable way of recording detailed changes in sports participation after ACL injury. The findings of this study support the content and concurrent validity of the survey, and suggest that the online activity survey can provide more complete data on sports participation than a routine activity questionnaire.
Quant, Cara; Altieri, Lisa; Torres, Juan; Craft, Noah
2016-01-01
Background. Mobile medical software applications (apps) are used for clinical decision-making at the point of care. Objectives. To determine (1) the usage, reliability, and popularity of mobile medical apps and (2) medical students' perceptions of app usage effect on the quality of patient-provider interaction in healthcare settings. Methods. An anonymous web-based survey was distributed to medical students. Frequency of use, type of app used, and perceptions of reliability were assessed via univariate analysis. Results. Seven hundred thirty-one medical students responded, equating to a response rate of 29%. The majority (90%) of participants thought that medical apps enhance clinical knowledge, and 61% said that medical apps are as reliable as textbooks. While students thought that medical apps save time, improve the care of their patients, and improve diagnostic accuracy, 53% of participants believed that mobile device use in front of colleagues and patients makes one appear less competent. Conclusion. While medical students believe in the utility and reliability of medical apps, they were hesitant to use them out of fear of appearing less engaged. Higher levels of training correlated with a greater degree of comfort when using medical apps in front of patients.
Li, Jia; Xia, Yunni; Luo, Xin
2014-01-01
OWL-S, one of the most important Semantic Web service ontologies proposed to date, provides a core ontological framework and guidelines for describing the properties and capabilities of their web services in an unambiguous, computer interpretable form. Predicting the reliability of composite service processes specified in OWL-S allows service users to decide whether the process meets the quantitative quality requirement. In this study, we consider the runtime quality of services to be fluctuating and introduce a dynamic framework to predict the runtime reliability of services specified in OWL-S, employing the Non-Markovian stochastic Petri net (NMSPN) and the time series model. The framework includes the following steps: obtaining the historical response times series of individual service components; fitting these series with a autoregressive-moving-average-model (ARMA for short) and predicting the future firing rates of service components; mapping the OWL-S process into a NMSPN model; employing the predicted firing rates as the model input of NMSPN and calculating the normal completion probability as the reliability estimate. In the case study, a comparison between the static model and our approach based on experimental data is presented and it is shown that our approach achieves higher prediction accuracy.
NASA Technical Reports Server (NTRS)
1998-01-01
NASA has transferred the improved portable leak detector technology to UE Systems, Inc.. This instrument was developed to detect leaks in fluid systems of critical launch and ground support equipment. This system incorporates innovative electronic circuitry, improved transducers, collecting horns, and contact sensors that provide a much higher degree of reliability, sensitivity and versatility over previously used systems. Potential commercial uses are pipelines, underground utilities, air-conditioning systems, petrochemical systems, aerospace, power transmission lines and medical devices.
The reliability of in-training assessment when performance improvement is taken into account.
van Lohuizen, Mirjam T; Kuks, Jan B M; van Hell, Elisabeth A; Raat, A N; Stewart, Roy E; Cohen-Schotanus, Janke
2010-12-01
During in-training assessment students are frequently assessed over a longer period of time and therefore it can be expected that their performance will improve. We studied whether there really is a measurable performance improvement when students are assessed over an extended period of time and how this improvement affects the reliability of the overall judgement. In-training assessment results were obtained from 104 students on rotation at our university hospital or at one of the six affiliated hospitals. Generalisability theory was used in combination with multilevel analysis to obtain reliability coefficients and to estimate the number of assessments needed for reliable overall judgement, both including and excluding performance improvement. Students' clinical performance ratings improved significantly from a mean of 7.6 at the start to a mean of 7.8 at the end of their clerkship. When taking performance improvement into account, reliability coefficients were higher. The number of assessments needed to achieve a reliability of 0.80 or higher decreased from 17 to 11. Therefore, when studying reliability of in-training assessment, performance improvement should be considered.
Reliability of 3D laser-based anthropometry and comparison with classical anthropometry.
Kuehnapfel, Andreas; Ahnert, Peter; Loeffler, Markus; Broda, Anja; Scholz, Markus
2016-05-26
Anthropometric quantities are widely used in epidemiologic research as possible confounders, risk factors, or outcomes. 3D laser-based body scans (BS) allow evaluation of dozens of quantities in short time with minimal physical contact between observers and probands. The aim of this study was to compare BS with classical manual anthropometric (CA) assessments with respect to feasibility, reliability, and validity. We performed a study on 108 individuals with multiple measurements of BS and CA to estimate intra- and inter-rater reliabilities for both. We suggested BS equivalents of CA measurements and determined validity of BS considering CA the gold standard. Throughout the study, the overall concordance correlation coefficient (OCCC) was chosen as indicator of agreement. BS was slightly more time consuming but better accepted than CA. For CA, OCCCs for intra- and inter-rater reliability were greater than 0.8 for all nine quantities studied. For BS, 9 of 154 quantities showed reliabilities below 0.7. BS proxies for CA measurements showed good agreement (minimum OCCC > 0.77) after offset correction. Thigh length showed higher reliability in BS while upper arm length showed higher reliability in CA. Except for these issues, reliabilities of CA measurements and their BS equivalents were comparable.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Yishen; Zhou, Zhi; Liu, Cong
2016-08-01
As more wind power and other renewable resources are being integrated into the electric power grid, the forecast uncertainty brings operational challenges for the power system operators. In this report, different operational strategies for uncertainty management are presented and evaluated. A comprehensive and consistent simulation framework is developed to analyze the performance of different reserve policies and scheduling techniques under uncertainty in wind power. Numerical simulations are conducted on a modified version of the IEEE 118-bus system with a 20% wind penetration level, comparing deterministic, interval, and stochastic unit commitment strategies. The results show that stochastic unit commitment provides amore » reliable schedule without large increases in operational costs. Moreover, decomposition techniques, such as load shift factor and Benders decomposition, can help in overcoming the computational obstacles to stochastic unit commitment and enable the use of a larger scenario set to represent forecast uncertainty. In contrast, deterministic and interval unit commitment tend to give higher system costs as more reserves are being scheduled to address forecast uncertainty. However, these approaches require a much lower computational effort Choosing a proper lower bound for the forecast uncertainty is important for balancing reliability and system operational cost in deterministic and interval unit commitment. Finally, we find that the introduction of zonal reserve requirements improves reliability, but at the expense of higher operational costs.« less
Reliability-Related Issues in the Context of Student Evaluations of Teaching in Higher Education
ERIC Educational Resources Information Center
Kalender, Ilker
2015-01-01
Student evaluations of teaching (SET) have been the principal instrument to elicit students' opinions in higher education institutions. Many decisions, including high-stake ones, are made based on SET scores reported by students. In this respect, reliability of SET scores is of considerable importance. This paper has an argument that there are…
NASA Astrophysics Data System (ADS)
Tan, Samantha H.; Chen, Ning; Liu, Shi; Wang, Kefei
2003-09-01
As part of the semiconductor industry "contamination-free manufacturing" effort, significant emphasis has been placed on reducing potential sources of contamination from process equipment and process equipment components. Process tools contain process chambers and components that are exposed to the process environment or process chemistry and in some cases are in direct contact with production wafers. Any contamination from these sources must be controlled or eliminated in order to maintain high process yields, device performance, and device reliability. This paper discusses new nondestructive analytical methods for quantitative measurement of the cleanliness of metal, quartz, polysilicon and ceramic components that are used in process equipment tools. The goal of these new procedures is to measure the effectiveness of cleaning procedures and to verify whether a tool component part is sufficiently clean for installation and subsequent routine use in the manufacturing line. These procedures provide a reliable "qualification method" for tool component certification and also provide a routine quality control method for reliable operation of cleaning facilities. Cost advantages to wafer manufacturing include higher yields due to improved process cleanliness and elimination of yield loss and downtime resulting from the installation of "bad" components in process tools. We also discuss a representative example of wafer contamination having been linked to a specific process tool component.
Impact of Distributed Energy Resources on the Reliability of a Critical Telecommunications Facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robinson, D.; Atcitty, C.; Zuffranieri, J.
2006-03-01
Telecommunications has been identified by the Department of Homeland Security as a critical infrastructure to the United States. Failures in the power systems supporting major telecommunications service nodes are a main contributor to major telecommunications outages, as documented by analyses of Federal Communications Commission (FCC) outage reports by the National Reliability Steering Committee (under auspices of the Alliance for Telecommunications Industry Solutions). There are two major issues that are having increasing impact on the sensitivity of the power distribution to telecommunication facilities: deregulation of the power industry, and changing weather patterns. A logical approach to improve the robustness of telecommunicationmore » facilities would be to increase the depth and breadth of technologies available to restore power in the face of power outages. Distributed energy resources such as fuel cells and gas turbines could provide one more onsite electric power source to provide backup power, if batteries and diesel generators fail. But does the diversity in power sources actually increase the reliability of offered power to the office equipment, or does the complexity of installing and managing the extended power system induce more potential faults and higher failure rates? This report analyzes a system involving a telecommunications facility consisting of two switch-bays and a satellite reception system.« less
Clayson, Peter E; Miller, Gregory A
2017-01-01
Generalizability theory (G theory) provides a flexible, multifaceted approach to estimating score reliability. G theory's approach to estimating score reliability has important advantages over classical test theory that are relevant for research using event-related brain potentials (ERPs). For example, G theory does not require parallel forms (i.e., equal means, variances, and covariances), can handle unbalanced designs, and provides a single reliability estimate for designs with multiple sources of error. This monograph provides a detailed description of the conceptual framework of G theory using examples relevant to ERP researchers, presents the algorithms needed to estimate ERP score reliability, and provides a detailed walkthrough of newly-developed software, the ERP Reliability Analysis (ERA) Toolbox, that calculates score reliability using G theory. The ERA Toolbox is open-source, Matlab software that uses G theory to estimate the contribution of the number of trials retained for averaging, group, and/or event types on ERP score reliability. The toolbox facilitates the rigorous evaluation of psychometric properties of ERP scores recommended elsewhere in this special issue. Copyright © 2016 Elsevier B.V. All rights reserved.
Colloidal-gold electrosensor measuring device
Wegner, S.; Harpold, M.A.; McCaffrey, T.M.; Morris, S.E.; Wojciechowski, M.; Zhao, J.; Henkens, R.W.; Naser, N.; O`Daly, J.P.
1995-11-21
The present invention provides a new device for use in measuring lead levels in biological and environmental samples. Using square wave coulometry and colloidal gold particles impregnated on carbon electrodes, the present invention provides a rapid, reliable, portable and inexpensive means of detecting low lead levels. The colloidal gold modified electrodes have microelectrode array characteristics and produce significantly higher stripping detection signals for lead than are produced at bulk gold electrode surfaces. The method is effective in determining levels of lead down to at least 5 {micro}g/dL in blood samples as small as 10 {micro}L. 9 figs.
Colloidal-gold electrosensor measuring device
Wegner, Steven; Harpold, Michael A.; McCaffrey, Terence M.; Morris, Susan E.; Wojciechowski, Marek; Zhao, Junguo; Henkens, Robert W.; Naser, Najih; O'Daly, John P.
1995-01-01
The present invention provides a new device for use in measuring lead levels in biological and environmental samples. Using square wave coulometry and colloidal gold particles impregnated on carbon electrodes, the present invention provides a rapid, reliable, portable and inexpensive means of detecting low lead levels. The colloidal gold modified electrodes have microelectrode array characteristics and produce significantly higher stripping detection signals for lead than are produced at bulk gold electrode surfaces. The method is effective in determining levels of lead down to at least 5 .mu.g/dL in blood samples as small as 10 .mu.L.
Estimating liver cancer deaths in Thailand based on verbal autopsy study.
Waeto, Salwa; Pipatjaturon, Nattakit; Tongkumchum, Phattrawan; Choonpradub, Chamnein; Saelim, Rattikan; Makaje, Nifatamah
2014-01-01
Liver cancer mortality is high in Thailand but utility of related vital statistics is limited due to national vital registration (VR) data being under reported for specific causes of deaths. Accurate methodologies and reliable supplementary data are needed to provide worthy national vital statistics. This study aimed to model liver cancer deaths based on verbal autopsy (VA) study in 2005 to provide more accurate estimates of liver cancer deaths than those reported. The results were used to estimate number of liver cancer deaths during 2000-2009. A verbal autopsy (VA) was carried out in 2005 based on a sample of 9,644 deaths from nine provinces and it provided reliable information on causes of deaths by gender, age group, location of deaths in or outside hospital, and causes of deaths of the VR database. Logistic regression was used to model liver cancer deaths and other variables. The estimated probabilities from the model were applied to liver cancer deaths in the VR database, 2000-2009. Thus, the more accurately VA-estimated numbers of liver cancer deaths were obtained. The model fits the data quite well with sensitivity 0.64. The confidence intervals from statistical model provide the estimates and their precisions. The VA-estimated numbers of liver cancer deaths were higher than the corresponding VR database with inflation factors 1.56 for males and 1.64 for females. The statistical methods used in this study can be applied to available mortality data in developing countries where their national vital registration data are of low quality and supplementary reliable data are available.
Stone, Lisanne L; Janssens, Jan M A M; Vermulst, Ad A; Van Der Maten, Marloes; Engels, Rutger C M E; Otten, Roy
2015-01-01
The Strengths and Difficulties Questionnaire is one of the most employed screening instruments. Although there is a large research body investigating its psychometric properties, reliability and validity are not yet fully tested using modern techniques. Therefore, we investigate reliability, construct validity, measurement invariance, and predictive validity of the parent and teacher version in children aged 4-7. Besides, we intend to replicate previous studies by investigating test-retest reliability and criterion validity. In a Dutch community sample 2,238 teachers and 1,513 parents filled out questionnaires regarding problem behaviors and parenting, while 1,831 children reported on sociometric measures at T1. These children were followed-up during three consecutive years. Reliability was examined using Cronbach's alpha and McDonald's omega, construct validity was examined by Confirmatory Factor Analysis, and predictive validity was examined by calculating developmental profiles and linking these to measures of inadequate parenting, parenting stress and social preference. Further, mean scores and percentiles were examined in order to establish norms. Omega was consistently higher than alpha regarding reliability. The original five-factor structure was replicated, and measurement invariance was established on a configural level. Further, higher SDQ scores were associated with future indices of higher inadequate parenting, higher parenting stress and lower social preference. Finally, previous results on test-retest reliability and criterion validity were replicated. This study is the first to show SDQ scores are predictively valid, attesting to the feasibility of the SDQ as a screening instrument. Future research into predictive validity of the SDQ is warranted.
[Design of low-intermediate frequency electrotherapy and pain assessment system].
Liang, Chunyan; Tian, Xuelong; Yu, Xuehong; Luo, Hongyan
2014-06-01
Aiming at the single treatment and the design separation between treatment and assessment in electrotherapy equipment, a kind of system including low-intermediate frequency treatment and efficacy evaluation was developed. With C8051F020 single-chip microcomputer as the core and the circuit design and software programming used, the system realized the random switch of therapeutic parameters, the collection, display and data storage of pressure pain threshold in the assessment. Experiment results showed that the stimulus waveform, current intensity, frequency, duty ratio of the system output were adjustable, accurate and reliable. The obtained pressure pain threshold had a higher accuracy (< 0.3 N) and better stability, guiding the parameter choice in the precise electrical stimulation. It, therefore, provides a reliable technical support for the treatment and curative effect assessment.
NASA Technical Reports Server (NTRS)
Eichenlaub, Carl T.; Harper, C. Douglas; Hird, Geoffrey
1993-01-01
Life-critical applications warrant a higher level of software reliability than has yet been achieved. Since it is not certain that traditional methods alone can provide the required ultra reliability, new methods should be examined as supplements or replacements. This paper describes a mathematical counterpart to the traditional process of empirical testing. ORA's Penelope verification system is demonstrated as a tool for evaluating the correctness of Ada software. Grady Booch's Ada calendar utility package, obtained through NASA, was specified in the Larch/Ada language. Formal verification in the Penelope environment established that many of the package's subprograms met their specifications. In other subprograms, failed attempts at verification revealed several errors that had escaped detection by testing.
Measuring eating disorder attitudes and behaviors: a reliability generalization study
2014-01-01
Background Although score reliability is a sample-dependent characteristic, researchers often only report reliability estimates from previous studies as justification for employing particular questionnaires in their research. The present study followed reliability generalization procedures to determine the mean score reliability of the Eating Disorder Inventory and its most commonly employed subscales (Drive for Thinness, Bulimia, and Body Dissatisfaction) and the Eating Attitudes Test as a way to better identify those characteristics that might impact score reliability. Methods Published studies that used these measures were coded based on their reporting of reliability information and additional study characteristics that might influence score reliability. Results Score reliability estimates were included in 26.15% of studies using the EDI and 36.28% of studies using the EAT. Mean Cronbach’s alphas for the EDI (total score = .91; subscales = .75 to .89), EAT-40 (total score = .81) and EAT-26 (total score = .86; subscales = .56 to .80) suggested variability in estimated internal consistency. Whereas some EDI subscales exhibited higher score reliability in clinical eating disorder samples than in nonclinical samples, other subscales did not exhibit these differences. Score reliability information for the EAT was primarily reported for nonclinical samples, making it difficult to characterize the effect of type of sample on these measures. However, there was a tendency for mean score reliability to be higher in the adult (vs. adolescent) samples and in female (vs. male) samples. Conclusions Overall, this study highlights the importance of assessing and reporting internal consistency during every test administration because reliability is affected by characteristics of the participants being examined. PMID:24764530
Volunteer Functions Inventory: A systematic review.
Chacón, Fernando; Gutiérrez, Gema; Sauto, Verónica; Vecina, María L; Pérez, Alfonso
2017-08-01
The objective of this research study was to conduct a systematic review of the research on volunteers using Clary et al.’s VFI (1998). A total of 48 research studies including 67 independent samples met eligibility criteria. The total sample of the studies analyzed ranged from 20375 to 21988 participants, depending on the motivation analyzed. The results show that the Values factor obtained the highest mean score, both overall and in each type of volunteering, whereas the lowest scores were for the Career and Enhancement factors. Studies conducted with samples with a mean age under 40 years obtain higher scores on Career and Understanding scales when compared to studies in older samples. The group of studies with less than 50% women yield higher mean scores on the Social scale than studies with more than 50% women in the sample. All the scales show reliability coefficients between .78 and .84. Only eight of the articles provide data on the reliability of the scale with a mean value of .90. Of the 26 studies that performed factor analysis, 18 confirmed the original structure of six factors.
Reliability of Computerized Neurocognitive Tests for Concussion Assessment: A Meta-Analysis.
Farnsworth, James L; Dargo, Lucas; Ragan, Brian G; Kang, Minsoo
2017-09-01
Although widely used, computerized neurocognitive tests (CNTs) have been criticized because of low reliability and poor sensitivity. A systematic review was published summarizing the reliability of Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) scores; however, this was limited to a single CNT. Expansion of the previous review to include additional CNTs and a meta-analysis is needed. Therefore, our purpose was to analyze reliability data for CNTs using meta-analysis and examine moderating factors that may influence reliability. A systematic literature search (key terms: reliability, computerized neurocognitive test, concussion) of electronic databases (MEDLINE, PubMed, Google Scholar, and SPORTDiscus) was conducted to identify relevant studies. Studies were included if they met all of the following criteria: used a test-retest design, involved at least 1 CNT, provided sufficient statistical data to allow for effect-size calculation, and were published in English. Two independent reviewers investigated each article to assess inclusion criteria. Eighteen studies involving 2674 participants were retained. Intraclass correlation coefficients were extracted to calculate effect sizes and determine overall reliability. The Fisher Z transformation adjusted for sampling error associated with averaging correlations. Moderator analyses were conducted to evaluate the effects of the length of the test-retest interval, intraclass correlation coefficient model selection, participant demographics, and study design on reliability. Heterogeneity was evaluated using the Cochran Q statistic. The proportion of acceptable outcomes was greatest for the Axon Sports CogState Test (75%) and lowest for the ImPACT (25%). Moderator analyses indicated that the type of intraclass correlation coefficient model used significantly influenced effect-size estimates, accounting for 17% of the variation in reliability. The Axon Sports CogState Test, which has a higher proportion of acceptable outcomes and shorter test duration relative to other CNTs, may be a reliable option; however, future studies are needed to compare the diagnostic accuracy of these instruments.
Development of the Daily Activities of Infants Scale: a measure supporting early motor development.
Bartlett, Doreen J; Fanning, Jamie Kneale; Miller, Linda; Conti-Becker, Angela; Doralp, Samantha
2008-08-01
We describe the development and preliminary psychometric testing of the Daily Activities of Infants Scale (DAIS), a parent-completed measure of opportunities parents provide infants for development of postural control and movement. First we obtained 1300 photographs of typical activities from 17 families with infants aged 4 to 11 months. Through consensus we established nine dimensions of activities, graded across three levels of opportunity for development. Pilot testing supported content validity of the DAIS. Subsequently, 50 parents of infants born preterm aged 4 to 11 months participated in psychometric testing. There were 25 male and 25 female infant participants with a mean gestational age of 29.4 weeks (SD 3.6) and a mean birthweight of 1266 grams (SD 635). We found that completion of the DAIS over 1 day was representative of data collected over 3 sequential days. Older infants obtained significantly higher DAIS scores than younger infants, providing preliminary evidence for discriminant validity. The DAIS scores demonstrated a part-correlation of 0.20 (p<0.01) with scores on the Alberta Infant Motor Scale obtained concurrently, providing some evidence for convergent validity. The intraclass correlation coefficients reflecting interrater reliability and test-retest reliability of the total DAIS score were 0.76 (95% confidence interval [CI] 0.60-0.86) and 0.77 (95% CI 0.60-0.87) respectively. The DAIS has sufficient reliability and validity for use in clinical practice and research.
Patrick, Donald L; Giuliano, François; Ho, Kai Fai; Gagnon, Dennis D; McNulty, Pauline; Rothman, Margaret
2009-02-01
To evaluate the reliability and validity of the Premature Ejaculation Profile (PEP), a self-reported outcome instrument for evaluating domains of PE and its treatment, comprised of four single-item measures, a profile, and an index score. Data were from men participating in observational studies in the USA (PE, 207 men; non-PE, 1380) and Europe (PE, 201; non-PE, 914) and from men with PE (1238) participating in a phase III randomized, placebo-controlled clinical trial of dapoxetine. The PEP contains four measures: perceived control over ejaculation, personal distress related to ejaculation, satisfaction with sexual intercourse, and interpersonal difficulty related to ejaculation, each assessed on five-point response scales. Test-retest reliability, known-groups validity, and ability to detect a patient-reported global impression of change (PGI) in condition were evaluated for the individual PEP measures and a PEP index score (the mean of all four measures). Profile analysis was conducted using multivariate analysis of variance. All PEP measures showed acceptable reliability (intraclass correlation coefficients ranged from 0.66 to 0.83) and mean scores for all measures differed significantly between PE and non-PE groups (P < 0.001). Men who reported a reduction in PE with treatment in the phase III trial had significantly greater scores on each of the four measures. The PEP profiles of men with and without PE differed significantly (P < 0.001) in both observational studies; higher levels of PGI were associated with higher PEP profiles (P < 0.001). The PEP index score also showed acceptable reliability and was significantly different between the PE and non-PE groups (P < 0.001). Men who reported an improvement in PE with treatment in the phase III trial had significantly greater PEP index scores. In the phase III trial, nausea was the most common adverse event with dapoxetine. The PEP provides a reliable, valid, and interpretable measure for use in monitoring outcomes of men with PE.
Pérez-Castilla, Alejandro; García-Ramos, Amador
2018-07-01
Pérez-Castilla, A and García-Ramos, A. Evaluation of the most reliable procedure of determining jump height during the loaded countermovement jump exercise: Take-off velocity vs. flight time. J Strength Cond Res 32(7): 2025-2030, 2018-This study aimed to compare the reliability of jump height between the 2 standard procedures of analyzing force-time data (take-off velocity [TOV] and flight time [FT]) during the loaded countermovement (CMJ) exercise performed with a free-weight barbell and in a Smith machine. The jump height of 17 men (age: 22.2 ± 2.2 years, body mass: 75.2 ± 7.1 kg, and height: 177.0 ± 6.0 cm) was tested in 4 sessions (twice for each CMJ type) against external loads of 17, 30, 45, 60, and 75 kg. Jump height reliability was comparable between the TOV (coefficient of variation [CV]: 6.42 ± 2.41%) and FT (CV: 6.53 ± 2.17%) during the free-weight CMJ, but it was higher for the FT when the CMJ was performed in a Smith machine (CV: 11.34 ± 3.73% for TOV and 5.95 ± 1.12% for FT). Bland-Altman plots revealed trivial differences (≤0.27 cm) and no heteroscedasticity of the errors (R ≤ 0.09) for the jump height obtained by the TOV and FT procedures, whereas the random error between both procedures was higher for the CMJ performed in the Smith machine (2.02 cm) compared with the free-weight barbell (1.26 cm). Based on these results, we recommend the FT procedure to determine jump height during the loaded CMJ performed in a Smith machine, whereas the TOV and FT procedures provide similar reliability during the free-weight CMJ.
Mau-Moeller, Anett; Gube, Martin; Felser, Sabine; Feldhege, Frank; Weippert, Matthias; Husmann, Florian; Tischer, Thomas; Bader, Rainer; Bruhn, Sven; Behrens, Martin
2017-08-17
To determine intrasession and intersession reliability of strength measurements and hamstrings to quadriceps strength imbalance ratios (H/Q ratios) using the new isoforce dynamometer. Repeated measures. Exercise science laboratory. Thirty healthy subjects (15 females, 15 males, 27.8 years). Coefficient of variation (CV) and intraclass correlation coefficients (ICC) were calculated for (1) strength parameters, that is peak torque, mean work, and mean power for concentric and eccentric maximal voluntary contractions; isometric maximal voluntary torque (IMVT); rate of torque development (RTD), and (2) H/Q ratios, that is conventional concentric, eccentric, and isometric H/Q ratios (Hcon/Qcon at 60 deg/s, 120 deg/s, and 180 deg/s, Hecc/Qecc at -60 deg/s and Hiso/Qiso) and functional eccentric antagonist to concentric agonist H/Q ratios (Hecc/Qcon and Hcon/Qecc). High reliability: CV <10%, ICC >0.90; moderate reliability: CV between 10% and 20%, ICC between 0.80 and 0.90; low reliability: CV >20%, ICC <0.80. (1) Strength parameters: (a) high intrasession reliability for concentric, eccentric, and isometric measurements, (b) moderate-to-high intersession reliability for concentric and eccentric measurements and IMVT, and (c) moderate-to-high intrasession reliability but low intersession reliability for RTD. (2) H/Q ratios: (a) moderate-to-high intrasession reliability for conventional ratios, (b) high intrasession reliability for functional ratios, (c) higher intersession reliability for Hcon/Qcon and Hiso/Qiso (moderate to high) than Hecc/Qecc (low to moderate), and (d) higher intersession reliability for conventional H/Q ratios (low to high) than functional H/Q ratios (low to moderate). The results have confirmed the reliability of strength parameters and the most frequently used H/Q ratios.
Paige, Samantha R; Krieger, Janice L; Stellefson, Michael; Alber, Julia M
2017-02-01
Chronic disease patients are affected by low computer and health literacy, which negatively affects their ability to benefit from access to online health information. To estimate reliability and confirm model specifications for eHealth Literacy Scale (eHEALS) scores among chronic disease patients using Classical Test (CTT) and Item Response Theory techniques. A stratified sample of Black/African American (N=341) and Caucasian (N=343) adults with chronic disease completed an online survey including the eHEALS. Item discrimination was explored using bi-variate correlations and Cronbach's alpha for internal consistency. A categorical confirmatory factor analysis tested a one-factor structure of eHEALS scores. Item characteristic curves, in-fit/outfit statistics, omega coefficient, and item reliability and separation estimates were computed. A 1-factor structure of eHEALS was confirmed by statistically significant standardized item loadings, acceptable model fit indices (CFI/TLI>0.90), and 70% variance explained by the model. Item response categories increased with higher theta levels, and there was evidence of acceptable reliability (ω=0.94; item reliability=89; item separation=8.54). eHEALS scores are a valid and reliable measure of self-reported eHealth literacy among Internet-using chronic disease patients. Providers can use eHEALS to help identify patients' eHealth literacy skills. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Ghirardelli, Alyssa; Quinn, Valerie; Sugerman, Sharon
2011-01-01
To develop a retail grocery instrument with weighted scoring to be used as an indicator of the food environment. Twenty six retail food stores in low-income areas in California. Observational. Inter-rater reliability for grocery store survey instrument. Description of store scoring methodology weighted to emphasize availability of healthful food. Type A intra-class correlation coefficients (ICC) with absolute agreement definition or a κ test for measures using ranges as categories. Measures of availability and price of fruits and vegetables performed well in reliability testing (κ = 0.681-0.800). Items for vegetable quality were better than for fruit (ICC 0.708 vs 0.528). Kappa scores indicated low to moderate agreement (0.372-0.674) on external store marketing measures and higher scores for internal store marketing. "Next to" the checkout counter was more reliable than "within 6 feet." Health departments using the store scoring system reported it as the most useful communication of neighborhood findings. There was good reliability of the measures among the research pairs. The local store scores can show the need to bring in resources and to provide access to fruits and vegetables and other healthful food. Copyright © 2011 Society for Nutrition Education. Published by Elsevier Inc. All rights reserved.
Fish, Rosemary A; Hogan, Michael J; Morrison, Todd G; Stewart, Ian; McGuire, Brian E
2013-03-01
An 8-item version of the Chronic Pain Acceptance Questionnaire (CPAQ-8) has recently been proposed and validated. The aims of this study were to further investigate the reliability and validity of the CPAQ-8 in a new sample. Questionnaires were completed by 550 people with chronic pain (478 online survey, 72 paper survey). A demographic and pain history questionnaire was administered along with the CPAQ-8 and measures of pain self-efficacy, pain catastrophizing, psychological flexibility in pain, anxiety, and mood. In addition, 105 respondents completed the CPAQ-8 within 6 weeks to provide test-retest reliability data. The 2-factor structure of the CPAQ-8 (Activity Engagement [AE] and Pain Willingness [PW]) was confirmed and had reasonable-to-good scale score reliability and test-retest reliability. Pain acceptance as measured by the CPAQ-8 was associated with less depression, anxiety, pain interference, fear of reinjury, pain catastrophizing, and psychological inflexibility in pain, and higher levels of satisfaction with life, pain self-efficacy, and general acceptance. Furthermore, pain acceptance fully mediated the relationship between reported pain severity and emotional distress (anxiety and depression) and partially mediated the relationship between pain severity and pain interference in a structural equation model. The test-retest reliability after 4 to 6 weeks ranged from .68 for PW to .86 for AE; the overall score correlation was .81. We conclude that the CPAQ-8 is a reliable and valid measure of pain acceptance and that the 2 subscales of the measure each make an individual contribution to the prediction of adjustment in people with chronic pain. The present study provides further evidence for the reliability and validity of the CPAQ-8. Support was found for the 2 related subscales, PW and AE, which appear to work in synergy to influence levels of pain interference and emotional distress in people living with chronic pain. Copyright © 2013 American Pain Society. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Aggarwal, Ankur
With the semiconductor industry racing toward a historic transition, nano chips with less than 45 nm features demand I/Os in excess of 20,000 that support computing speed in terabits per second, with multi-core processors aggregately providing highest bandwidth at lowest power. On the other hand, emerging mixed signal systems are driving the need for 3D packaging with embedded active components and ultra-short interconnections. Decreasing I/O pitch together with low cost, high electrical performance and high reliability are the key technological challenges identified by the 2005 International Technology Roadmap for Semiconductors (ITRS). Being able to provide several fold increase in the chip-to-package vertical interconnect density is essential for garnering the true benefits of nanotechnology that will utilize nano-scale devices. Electrical interconnections are multi-functional materials that must also be able to withstand complex, sustained and cyclic thermo-mechanical loads. In addition, the materials must be environmentally-friendly, corrosion resistant, thermally stable over a long time, and resistant to electro-migration. A major challenge is also to develop economic processes that can be integrated into back end of the wafer foundry, i.e. with wafer level packaging. Device-to-system board interconnections are typically accomplished today with either wire bonding or solders. Both of these are incremental and run into either electrical or mechanical barriers as they are extended to higher density of interconnections. Downscaling traditional solder bump interconnect will not satisfy the thermo-mechanical reliability requirements at very fine pitches of the order of 30 microns and less. Alternate interconnection approaches such as compliant interconnects typically require lengthy connections and are therefore limited in terms of electrical properties, although expected to meet the mechanical requirements. A novel chip-package interconnection technology is developed to address the IC packaging requirements beyond the ITRS projections and to introduce innovative design and fabrication concepts that will further advance the performance of the chip, the package, and the system board. The nano-structured interconnect technology simultaneously packages all the ICs intact in wafer form with quantum jump in the number of interconnections with the lowest electrical parasitics. The intrinsic properties of nano materials also enable several orders of magnitude higher interconnect densities with the best mechanical properties for the highest reliability and yet provide higher current and heat transfer densities. Nano-structured interconnects provides the ability to assemble the packaged parts on the system board without the use of underfill materials and to enable advanced analog/digital testing, reliability testing, and burn-in at wafer level. This thesis investigates the electrical and mechanical performance of nanostructured interconnections through modeling and test vehicle fabrication. The analytical models evaluate the performance improvements over solder and compliant interconnections. Test vehicles with nano-interconnections were fabricated using low cost electro-deposition techniques and assembled with various bonding interfaces. Interconnections were fabricated at 200 micron pitch to compare with the existing solder joints and at 50 micron pitch to demonstrate fabrication processes at fine pitches. Experimental and modeling results show that the proposed nano-interconnections could enhance the reliability and potentially meet all the system performance requirements for the emerging micro/nano-systems.
Weech-Maldonado, Robert; Dreachslin, Janice L; Brown, Julie; Pradhan, Rohit; Rubin, Kelly L; Schiller, Cameron; Hays, Ron D
2012-01-01
The U.S. national standards for culturally and linguistically appropriate services (CLAS) in health care provide guidelines on policies and practices aimed at developing culturally competent systems of care. The Cultural Competency Assessment Tool for Hospitals (CCATH) was developed as an organizational tool to assess adherence to the CLAS standards. First, we describe the development of the CCATH and estimate the reliability and validity of the CCATH measures. Second, we discuss the managerial implications of the CCATH as an organizational tool to assess cultural competency. We pilot tested an initial draft of the CCATH, revised it based on a focus group and cognitive interviews, and then administered it in a field test with a sample of California hospitals. The reliability and validity of the CCATH were evaluated using factor analysis, analysis of variance, and Cronbach's alphas. Exploratory and confirmatory factor analyses identified 12 CCATH composites: leadership and strategic planning, data collection on inpatient population, data collection on service area, performance management systems and quality improvement, human resources practices, diversity training, community representation, availability of interpreter services, interpreter services policies, quality of interpreter services, translation of written materials, and clinical cultural competency practices. All the CCATH scales had internal consistency reliability of .65 or above, and the reliability was .70 or above for 9 of the 12 scales. Analysis of variance results showed that not-for-profit hospitals have higher CCATH scores than for-profit hospitals in five CCATH scales and higher CCATH scores than government hospitals in two CCATH scales. The CCATH showed adequate psychometric properties. Managers and policy makers can use the CCATH as a tool to evaluate hospital performance in cultural competency and identify and target improvements in hospital policies and practices that undergird the provision of CLAS.
Lockheed L-1101 avionic flight control redundant systems
NASA Technical Reports Server (NTRS)
Throndsen, E. O.
1976-01-01
The Lockheed L-1011 automatic flight control systems - yaw stability augmentation and automatic landing - are described in terms of their redundancies. The reliability objectives for these systems are discussed and related to in-service experience. In general, the availability of the stability augmentation system is higher than the original design requirement, but is commensurate with early estimates. The in-service experience with automatic landing is not sufficient to provide verification of Category 3 automatic landing system estimated availability.
Smerecnik, Chris M R; Mesters, Ilse; Candel, Math J J M; De Vries, Hein; De Vries, Nanne K
2012-01-01
The role of information processing in understanding people's responses to risk information has recently received substantial attention. One limitation of this research concerns the unavailability of a validated questionnaire of information processing. This article presents two studies in which we describe the development and validation of the Information-Processing Questionnaire to meet that need. Study 1 describes the development and initial validation of the questionnaire. Participants were randomized to either a systematic processing or a heuristic processing condition after which they completed a manipulation check and the initial 15-item questionnaire and again two weeks later. The questionnaire was subjected to factor reliability and validity analyses on both measurement times for purposes of cross-validation of the results. A two-factor solution was observed representing a systematic processing and a heuristic processing subscale. The resulting scale showed good reliability and validity, with the systematic condition scoring significantly higher on the systematic subscale and the heuristic processing condition significantly higher on the heuristic subscale. Study 2 sought to further validate the questionnaire in a field study. Results of the second study corresponded with those of Study 1 and provided further evidence of the validity of the Information-Processing Questionnaire. The availability of this information-processing scale will be a valuable asset for future research and may provide researchers with new research opportunities. © 2011 Society for Risk Analysis.
Hoerger, Michael; Chapman, Benjamin P; Mohile, Supriya G; Duberstein, Paul R
2016-09-01
In light of recent health care reforms, we have provided an illustrative example of new opportunities available for psychologists to develop patient-reported measures related to health care quality. Patient engagement in health care decision making has been increasingly acknowledged as a vital component of quality cancer care. We developed the 10-item Decisional Engagement Scale (DES-10), a patient-reported measure of engagement in decision making in cancer care that assesses patients' awareness of their diagnosis, sense of empowerment and involvement, and level of information seeking and planning. The National Institutes of Health's ResearchMatch recruitment tool was used to facilitate Internet-mediated data collection from 376 patients with cancer. DES-10 scores demonstrated good internal consistency reliability (α = .80), and the hypothesized unidimensional factor structure fit the data well. The reliability and factor structure were supported across subgroups based on demographic, socioeconomic, and health characteristics. Higher DES-10 scores were associated with better health-related quality of life (r = .31). In concurrent validity analyses controlling for age, socioeconomic status, and health-related quality of life, higher DES-10 scores were associated with higher scores on quality-of-care indices, including greater awareness of one's treatments, greater preferences for shared decision making, and clearer preferences about end-of-life care. A mini-measure, the DES-3, also performed well psychometrically. In conclusion, DES-10 and DES-3 scores showed evidence of reliability and validity, and these brief patient-reported measures can be used by researchers, clinicians, nonprofits, hospitals, insurers, and policymakers interested in evaluating and improving the quality of cancer care. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Pérez-Castilla, Alejandro; McMahon, John J; Comfort, Paul; García-Ramos, Amador
2017-07-31
The aims of this study were to compare the reliability and magnitude of jump height between the two standard procedures of analysing force platform data to estimate jump height (take-off velocity [TOV] and flight time [FT]) in the loaded squat jump (SJ) exercise performed with a free-weight barbell and in a Smith machine. Twenty-three collegiate men (age 23.1 ± 3.2 years, body mass 74.7 ± 7.3 kg, height 177.1 ± 7.0 cm) were tested twice for each SJ type (free-weight barbell and Smith machine) with 17, 30, 45, 60, and 75 kg loads. No substantial differences in reliability were observed between the TOV (Coefficient of variation [CV]: 9.88%; Intraclass correlation coefficient [ICC]: 0.82) and FT (CV: 8.68%; ICC: 0.88) procedures (CV ratio: 1.14), while the Smith SJ (CV: 7.74%; ICC: 0.87) revealed a higher reliability than the free-weight SJ (CV: 9.88%; ICC: 0.81) (CV ratio: 1.28). The TOV procedure provided higher magnitudes of jump height than the FT procedure for the loaded Smith machine SJ (systematic bias: 2.64 cm; P<0.05), while no significant differences between the TOV and FT procedures were observed in the free-weight SJ exercise (systematic bias: 0.26 cm; P>0.05). Heteroscedasticity of the errors was observed for the Smith machine SJ (r: 0.177) with increasing differences in favour of the TOV procedure for the trials with lower jump height (i.e. higher external loads). Based on these results the use of a Smith machine in conjunction with the FT more accurately determine jump height during the loaded SJ.
Wu, X; Lund, M S; Sun, D; Zhang, Q; Su, G
2015-10-01
One of the factors affecting the reliability of genomic prediction is the relationship among the animals of interest. This study investigated the reliability of genomic prediction in various scenarios with regard to the relationship between test and training animals, and among animals within the training data set. Different training data sets were generated from EuroGenomics data and a group of Nordic Holstein bulls (born in 2005 and afterwards) as a common test data set. Genomic breeding values were predicted using a genomic best linear unbiased prediction model and a Bayesian mixture model. The results showed that a closer relationship between test and training animals led to a higher reliability of genomic predictions for the test animals, while a closer relationship among training animals resulted in a lower reliability. In addition, the Bayesian mixture model in general led to a slightly higher reliability of genomic prediction, especially for the scenario of distant relationships between training and test animals. Therefore, to prevent a decrease in reliability, constant updates of the training population with animals from more recent generations are required. Moreover, a training population consisting of less-related animals is favourable for reliability of genomic prediction. © 2015 Blackwell Verlag GmbH.
Brůžek, Jaroslav; Santos, Frédéric; Dutailly, Bruno; Murail, Pascal; Cunha, Eugenia
2017-10-01
A new tool for skeletal sex estimation based on measurements of the human os coxae is presented using skeletons from a metapopulation of identified adult individuals from twelve independent population samples. For reliable sex estimation, a posterior probability greater than 0.95 was considered to be the classification threshold: below this value, estimates are considered indeterminate. By providing free software, we aim to develop an even more disseminated method for sex estimation. Ten metric variables collected from 2,040 ossa coxa of adult subjects of known sex were recorded between 1986 and 2002 (reference sample). To test both the validity and reliability, a target sample consisting of two series of adult ossa coxa of known sex (n = 623) was used. The DSP2 software (Diagnose Sexuelle Probabiliste v2) is based on Linear Discriminant Analysis, and the posterior probabilities are calculated using an R script. For the reference sample, any combination of four dimensions provides a correct sex estimate in at least 99% of cases. The percentage of individuals for whom sex can be estimated depends on the number of dimensions; for all ten variables it is higher than 90%. Those results are confirmed in the target sample. Our posterior probability threshold of 0.95 for sex estimate corresponds to the traditional sectioning point used in osteological studies. DSP2 software is replacing the former version that should not be used anymore. DSP2 is a robust and reliable technique for sexing adult os coxae, and is also user friendly. © 2017 Wiley Periodicals, Inc.
To repair or not to repair: with FAVOR there is no question
NASA Astrophysics Data System (ADS)
Garetto, Anthony; Schulz, Kristian; Tabbone, Gilles; Himmelhaus, Michael; Scheruebl, Thomas
2016-10-01
In the mask shop the challenges associated with today's advanced technology nodes, both technical and economic, are becoming increasingly difficult. The constant drive to continue shrinking features means more masks per device, smaller manufacturing tolerances and more complexity along the manufacturing line with respect to the number of manufacturing steps required. Furthermore, the extremely competitive nature of the industry makes it critical for mask shops to optimize asset utilization and processes in order to maximize their competitive advantage and, in the end, profitability. Full maximization of profitability in such a complex and technologically sophisticated environment simply cannot be achieved without the use of smart automation. Smart automation allows productivity to be maximized through better asset utilization and process optimization. Reliability is improved through the minimization of manual interactions leading to fewer human error contributions and a more efficient manufacturing line. In addition to these improvements in productivity and reliability, extra value can be added through the collection and cross-verification of data from multiple sources which provides more information about our products and processes. When it comes to handling mask defects, for instance, the process consists largely of time consuming manual interactions that are error prone and often require quick decisions from operators and engineers who are under pressure. The handling of defects itself is a multiple step process consisting of several iterations of inspection, disposition, repair, review and cleaning steps. Smaller manufacturing tolerances and features with higher complexity contribute to a higher number of defects which must be handled as well as a higher level of complexity. In this paper the recent efforts undertaken by ZEISS to provide solutions which address these challenges, particularly those associated with defectivity, will be presented. From automation of aerial image analysis to the use of data driven decision making to predict and propose the optimized back end of line process flow, productivity and reliability improvements are targeted by smart automation. Additionally the generation of the ideal aerial image from the design and several repair enhancement features offer additional capabilities to improve the efficiency and yield associated with defect handling.
Singendonk, M M J; Smits, M J; Heijting, I E; van Wijk, M P; Nurko, S; Rosen, R; Weijenborg, P W; Abu-Assi, R; Hoekman, D R; Kuizenga-Wessel, S; Seiboth, G; Benninga, M A; Omari, T I; Kritas, S
2015-02-01
The Chicago Classification (CC) facilitates interpretation of high-resolution manometry (HRM) recordings. Application of this adult based algorithm to the pediatric population is unknown. We therefore assessed intra and interrater reliability of software-based CC diagnosis in a pediatric cohort. Thirty pediatric solid state HRM recordings (13M; mean age 12.1 ± 5.1 years) assessing 10 liquid swallows per patient were analyzed twice by 11 raters (six experts, five non-experts). Software-placed anatomical landmarks required manual adjustment or removal. Integrated relaxation pressure (IRP4s), distal contractile integral (DCI), contractile front velocity (CFV), distal latency (DL) and break size (BS), and an overall CC diagnosis were software-generated. In addition, raters provided their subjective CC diagnosis. Reliability was calculated with Cohen's and Fleiss' kappa (κ) and intraclass correlation coefficient (ICC). Intra- and interrater reliability of software-generated CC diagnosis after manual adjustment of landmarks was substantial (mean κ = 0.69 and 0.77 respectively) and moderate-substantial for subjective CC diagnosis (mean κ = 0.70 and 0.58 respectively). Reliability of both software-generated and subjective diagnosis of normal motility was high (κ = 0.81 and κ = 0.79). Intra- and interrater reliability were excellent for IRP4s, DCI, and BS. Experts had higher interrater reliability than non-experts for DL (ICC = 0.65 vs ICC = 0.36 respectively) and the software-generated diagnosis diffuse esophageal spasm (DES, κ = 0.64 vs κ = 0.30). Among experts, the reliability for the subjective diagnosis of achalasia and esophageal gastric junction outflow obstruction was moderate-substantial (κ = 0.45-0.82). Inter- and intrarater reliability of software-based CC diagnosis of pediatric HRM recordings was high overall. However, experience was a factor influencing the diagnosis of some motility disorders, particularly DES and achalasia. © 2014 John Wiley & Sons Ltd.
Development of a measure of the experience of being bullied in youth.
Hunt, Caroline; Peters, Lorna; Rapee, Ronald M
2012-03-01
The Personal Experiences Checklist (PECK) was developed to provide a multidimensional assessment of a young person's personal experience of being bullied that covered the full range of bullying behaviors, including covert relational forms of bullying and cyber bullying. A sample of 647 school children were used to develop the scale, and a 2nd sample of 218 children completed the PECK and a battery of measures of bullying (including peer nomination), anxiety, depression, and self-esteem, to provide validity evidence. Test-retest reliability was assessed in a further sample of 78 students. Four factors emerged from a principal axis factoring consistent with the domains of relational-verbal bullying, cyber bullying, physical bullying, and bullying based on culture and were confirmed with confirmatory factor analysis. The data also supported a higher order bullying factor with direct effects on these 4 factors. All PECK scales showed good to excellent internal consistency (Cronbach's α range = .78-.91) and adequate test-retest reliability (range r = .61-.86). Most, but not all, expected relations were found with alternative methods of assessing bullying and measures of psychopathology. Taken together, the PECK provides a promising comprehensive and behaviorally focused dimensional measure of bullying.
Demand Response For Power System Reliability: FAQ
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kirby, Brendan J
2006-12-01
Demand response is the most underutilized power system reliability resource in North America. Technological advances now make it possible to tap this resource to both reduce costs and improve. Misconceptions concerning response capabilities tend to force loads to provide responses that they are less able to provide and often prohibit them from providing the most valuable reliability services. Fortunately this is beginning to change with some ISOs making more extensive use of load response. This report is structured as a series of short questions and answers that address load response capabilities and power system reliability needs. Its objective is tomore » further the use of responsive load as a bulk power system reliability resource in providing the fastest and most valuable ancillary services.« less
Providing reliable route guidance : phase II.
DOT National Transportation Integrated Search
2010-12-20
The overarching goal of the project is to enhance travel reliability of highway users by providing : them with reliable route guidance produced from newly developed routing algorithms that : are validated and implemented with real traffic data. To th...
Scheduler for multiprocessor system switch with selective pairing
Gara, Alan; Gschwind, Michael Karl; Salapura, Valentina
2015-01-06
System, method and computer program product for scheduling threads in a multiprocessing system with selective pairing of processor cores for increased processing reliability. A selective pairing facility is provided that selectively connects, i.e., pairs, multiple microprocessor or processor cores to provide one highly reliable thread (or thread group). The method configures the selective pairing facility to use checking provide one highly reliable thread for high-reliability and allocate threads to corresponding processor cores indicating need for hardware checking. The method configures the selective pairing facility to provide multiple independent cores and allocate threads to corresponding processor cores indicating inherent resilience.
NASA Technical Reports Server (NTRS)
Baldwin, Richard S.; Guzik, Monica; Skierski, Michael
2011-01-01
As NASA prepares for its next era of manned spaceflight missions, advanced energy storage technologies are being developed and evaluated to address future mission needs and technical requirements and to provide new mission-enabling technologies. Cell-level components for advanced lithium-ion batteries possessing higher energy, more reliable performance and enhanced, inherent safety characteristics are actively under development within the NASA infrastructure. A key component for safe and reliable cell performance is the cell separator, which separates the two energetic electrodes and functions to prevent the occurrence of an internal short-circuit while enabling ionic transport. Recently, a new generation of co-extruded separator films has been developed by ExxonMobil Chemical and introduced into their battery separator product portfolio. Several grades of this new separator material have been evaluated with respect to dynamic mechanical properties and safety-related performance attributes. This paper presents the results of these evaluations in comparison to a current state-ofthe-practice separator material. The results are discussed with respect to potential opportunities to enhance the inherent safety characteristics and reliability of future, advanced lithium-ion cell chemistries.
Validity and Reliability of a General Nutrition Knowledge Questionnaire for Japanese Adults.
Matsumoto, Mai; Tanaka, Rie; Ikemoto, Shinji
2017-01-01
Nutrition knowledge is necessary for individuals to adopt appropriate dietary habits, and needs to be evaluated before nutrition education is provided. However, there is no tool to assess general nutrition knowledge of adults in Japan. Our aims were to determine the validity and reliability of a general nutrition knowledge questionnaire for Japanese adults. We developed the pilot version of the Japanese general nutrition knowledge questionnaire (JGNKQ) and administered the pilot study to assess content validity and internal reliability to 1,182 Japanese adults aged 18-64 y. The JGNKQ was further modified based on the pilot study and the final version consisted of 5 sections and 147 items. The JGNKQ was administered to female undergraduate Japanese students in their senior year twice in 2015 to assess construct validity and test-retest reliability. Ninety-six students majoring in nutrition and 44 students in other majors who studied at the same university completed the first questionnaire. Seventy-five students completed the questionnaire twice. The responses from the first questionnaire and both questionnaires were used to assess construct validity and test-retest reliability, respectively. The students in nutrition major had significantly higher scores than the students in other majors on all sections of the questionnaire (p=0.000); therefore, the questionnaire had good construct validity. The test-retest reliability correlation coefficient value of overall and each section except "The use of dietary information to make dietary choices" were 0.75, 0.67, 0.67, 0.68 and 0.61, respectively. We suggest that the JGNKQ is an effective tool to assess the nutrition knowledge level of Japanese adults.
Reliability of COPVs Accounting for Margin of Safety on Design Burst
NASA Technical Reports Server (NTRS)
Murthy, Pappu L.N.
2012-01-01
In this paper, the stress rupture reliability of Carbon/Epoxy Composite Overwrapped Pressure Vessels (COPVs) is examined utilizing the classic Phoenix model and accounting for the differences between the design and the actual burst pressure, and the liner contribution effects. Stress rupture life primarily depends upon the fiber stress ratio which is defined as the ratio of stress in fibers at the maximum expected operating pressure to actual delivered fiber strength. The actual delivered fiber strength is calculated using the actual burst pressures of vessels established through burst tests. However, during the design phase the actual burst pressure is generally not known and to estimate the reliability of the vessels calculations are usually performed based upon the design burst pressure only. Since the design burst is lower than the actual burst, this process yields a much higher value for the stress ratio and consequently a conservative estimate for the reliability. Other complications arise due to the fact that the actual burst pressure and the liner contributions have inherent variability and therefore must be treated as random variables in order to compute the stress rupture reliability. Furthermore, the model parameters, which have to be established based on stress rupture tests of subscale vessels or coupons, have significant variability as well due to limited available data and hence must be properly accounted for. In this work an assessment of reliability of COPVs including both parameter uncertainties and physical variability inherent in liner and overwrap material behavior is made and estimates are provided in terms of degree of uncertainty in the actual burst pressure and the liner load sharing.
NASA Astrophysics Data System (ADS)
Kondo, Yoshihisa; Yomo, Hiroyuki; Yamaguchi, Shinji; Davis, Peter; Miura, Ryu; Obana, Sadao; Sampei, Seiichi
This paper proposes multipoint-to-multipoint (MPtoMP) real-time broadcast transmission using network coding for ad-hoc networks like video game networks. We aim to achieve highly reliable MPtoMP broadcasting using IEEE 802.11 media access control (MAC) that does not include a retransmission mechanism. When each node detects packets from the other nodes in a sequence, the correctly detected packets are network-encoded, and the encoded packet is broadcasted in the next sequence as a piggy-back for its native packet. To prevent increase of overhead in each packet due to piggy-back packet transmission, network coding vector for each node is exchanged between all nodes in the negotiation phase. Each user keeps using the same coding vector generated in the negotiation phase, and only coding information that represents which user signal is included in the network coding process is transmitted along with the piggy-back packet. Our simulation results show that the proposed method can provide higher reliability than other schemes using multi point relay (MPR) or redundant transmissions such as forward error correction (FEC). We also implement the proposed method in a wireless testbed, and show that the proposed method achieves high reliability in a real-world environment with a practical degree of complexity when installed on current wireless devices.
Craft, Noah
2016-01-01
Background. Mobile medical software applications (apps) are used for clinical decision-making at the point of care. Objectives. To determine (1) the usage, reliability, and popularity of mobile medical apps and (2) medical students' perceptions of app usage effect on the quality of patient-provider interaction in healthcare settings. Methods. An anonymous web-based survey was distributed to medical students. Frequency of use, type of app used, and perceptions of reliability were assessed via univariate analysis. Results. Seven hundred thirty-one medical students responded, equating to a response rate of 29%. The majority (90%) of participants thought that medical apps enhance clinical knowledge, and 61% said that medical apps are as reliable as textbooks. While students thought that medical apps save time, improve the care of their patients, and improve diagnostic accuracy, 53% of participants believed that mobile device use in front of colleagues and patients makes one appear less competent. Conclusion. While medical students believe in the utility and reliability of medical apps, they were hesitant to use them out of fear of appearing less engaged. Higher levels of training correlated with a greater degree of comfort when using medical apps in front of patients. PMID:27688752
Maximally reliable spatial filtering of steady state visual evoked potentials.
Dmochowski, Jacek P; Greaves, Alex S; Norcia, Anthony M
2015-04-01
Due to their high signal-to-noise ratio (SNR) and robustness to artifacts, steady state visual evoked potentials (SSVEPs) are a popular technique for studying neural processing in the human visual system. SSVEPs are conventionally analyzed at individual electrodes or linear combinations of electrodes which maximize some variant of the SNR. Here we exploit the fundamental assumption of evoked responses--reproducibility across trials--to develop a technique that extracts a small number of high SNR, maximally reliable SSVEP components. This novel spatial filtering method operates on an array of Fourier coefficients and projects the data into a low-dimensional space in which the trial-to-trial spectral covariance is maximized. When applied to two sample data sets, the resulting technique recovers physiologically plausible components (i.e., the recovered topographies match the lead fields of the underlying sources) while drastically reducing the dimensionality of the data (i.e., more than 90% of the trial-to-trial reliability is captured in the first four components). Moreover, the proposed technique achieves a higher SNR than that of the single-best electrode or the Principal Components. We provide a freely-available MATLAB implementation of the proposed technique, herein termed "Reliable Components Analysis". Copyright © 2015 Elsevier Inc. All rights reserved.
Development and validation of an instrument for evaluating inquiry-based tasks in science textbooks
NASA Astrophysics Data System (ADS)
Yang, Wenyuan; Liu, Enshan
2016-12-01
This article describes the development and validation of an instrument that can be used for content analysis of inquiry-based tasks. According to the theories of educational evaluation and qualities of inquiry, four essential functions that inquiry-based tasks should serve are defined: (1) assisting in the construction of understandings about scientific concepts, (2) providing students opportunities to use inquiry process skills, (3) being conducive to establishing understandings about scientific inquiry, and (4) giving students opportunities to develop higher order thinking skills. An instrument - the Inquiry-Based Tasks Analysis Inventory (ITAI) - was developed to judge whether inquiry-based tasks perform these functions well. To test the reliability and validity of the ITAI, 4 faculty members were invited to use the ITAI to collect data from 53 inquiry-based tasks in the 3 most widely adopted senior secondary biology textbooks in Mainland China. The results indicate that (1) the inter-rater reliability reached 87.7%, (2) the grading criteria have high discriminant validity, (3) the items possess high convergent validity, and (4) the Cronbach's alpha reliability coefficient reached 0.792. The study concludes that the ITAI is valid and reliable. Because of its solid foundations in theoretical and empirical argumentation, the ITAI is trustworthy.
Reliability Prediction of Ontology-Based Service Compositions Using Petri Net and Time Series Models
Li, Jia; Xia, Yunni; Luo, Xin
2014-01-01
OWL-S, one of the most important Semantic Web service ontologies proposed to date, provides a core ontological framework and guidelines for describing the properties and capabilities of their web services in an unambiguous, computer interpretable form. Predicting the reliability of composite service processes specified in OWL-S allows service users to decide whether the process meets the quantitative quality requirement. In this study, we consider the runtime quality of services to be fluctuating and introduce a dynamic framework to predict the runtime reliability of services specified in OWL-S, employing the Non-Markovian stochastic Petri net (NMSPN) and the time series model. The framework includes the following steps: obtaining the historical response times series of individual service components; fitting these series with a autoregressive-moving-average-model (ARMA for short) and predicting the future firing rates of service components; mapping the OWL-S process into a NMSPN model; employing the predicted firing rates as the model input of NMSPN and calculating the normal completion probability as the reliability estimate. In the case study, a comparison between the static model and our approach based on experimental data is presented and it is shown that our approach achieves higher prediction accuracy. PMID:24688429
Simulation-Based Training for Colonoscopy
Preisler, Louise; Svendsen, Morten Bo Søndergaard; Nerup, Nikolaj; Svendsen, Lars Bo; Konge, Lars
2015-01-01
Abstract The aim of this study was to create simulation-based tests with credible pass/fail standards for 2 different fidelities of colonoscopy models. Only competent practitioners should perform colonoscopy. Reliable and valid simulation-based tests could be used to establish basic competency in colonoscopy before practicing on patients. Twenty-five physicians (10 consultants with endoscopic experience and 15 fellows with very little endoscopic experience) were tested on 2 different simulator models: a virtual-reality simulator and a physical model. Tests were repeated twice on each simulator model. Metrics with discriminatory ability were identified for both modalities and reliability was determined. The contrasting-groups method was used to create pass/fail standards and the consequences of these were explored. The consultants significantly performed faster and scored higher than the fellows on both the models (P < 0.001). Reliability analysis showed Cronbach α = 0.80 and 0.87 for the virtual-reality and the physical model, respectively. The established pass/fail standards failed one of the consultants (virtual-reality simulator) and allowed one fellow to pass (physical model). The 2 tested simulations-based modalities provided reliable and valid assessments of competence in colonoscopy and credible pass/fail standards were established for both the tests. We propose to use these standards in simulation-based training programs before proceeding to supervised training on patients. PMID:25634177
Assessment of physical server reliability in multi cloud computing system
NASA Astrophysics Data System (ADS)
Kalyani, B. J. D.; Rao, Kolasani Ramchand H.
2018-04-01
Business organizations nowadays functioning with more than one cloud provider. By spreading cloud deployment across multiple service providers, it creates space for competitive prices that minimize the burden on enterprises spending budget. To assess the software reliability of multi cloud application layered software reliability assessment paradigm is considered with three levels of abstractions application layer, virtualization layer, and server layer. The reliability of each layer is assessed separately and is combined to get the reliability of multi-cloud computing application. In this paper, we focused on how to assess the reliability of server layer with required algorithms and explore the steps in the assessment of server reliability.
Feasibility of magnetic bearings for advanced gas turbine engines
NASA Technical Reports Server (NTRS)
Hibner, David; Rosado, Lewis
1992-01-01
The application of active magnetic bearings to advanced gas turbine engines will provide a product with major improvements compared to current oil lubricated bearing designs. A rethinking of the engine rotating and static structure design is necessary and will provide the designer with significantly more freedom to meet the demanding goals of improved performance, increased durability, higher reliability, and increased thrust to weight ratio via engine weight reduction. The product specific technology necessary for this high speed, high temperature, dynamically complex application has been defined. The resulting benefits from this approach to aircraft engine rotor support and the complementary engine changes and improvements have been assessed.
Standby battery requirements for telecommunications power
NASA Astrophysics Data System (ADS)
May, G. J.
The requirements for standby power for telecommunications are changing as the network moves from conventional systems to Internet Protocol (IP) telephony. These new systems require higher power levels closer to the user but the level of availability and reliability cannot be compromised if the network is to provide service in the event of a failure of the public utility. Many parts of these new networks are ac rather than dc powered with UPS systems for back-up power. These generally have lower levels of reliability than dc systems and the network needs to be designed such that overall reliability is not reduced through appropriate levels of redundancy. Mobile networks have different power requirements. Where there is a high density of nodes, continuity of service can be reasonably assured with short autonomy times. Furthermore, there is generally no requirement that these networks are the provider of last resort and therefore, specifications for continuity of power are directed towards revenue protection and overall reliability targets. As a result of these changes, battery requirements for reserve power are evolving. Shorter autonomy times are specified for parts of the network although a large part will continue to need support for hours rather minutes. Operational temperatures are increasing and battery solutions that provide longer life in extreme conditions are becoming important. Different battery technologies will be discussed in the context of these requirements. Conventional large flooded lead/acid cells both with pasted and tubular plates are used in larger central office applications but the majority of requirements are met with valve-regulated lead/acid (VRLA) batteries. The different types of VRLA battery will be described and their suitability for various applications outlined. New developments in battery construction and battery materials have improved both performance and reliability in recent years. Alternative technologies are also being proposed for telecommunications power, either different battery chemistries including lithium batteries, flywheel energy storage or the use of fuel cells. These will be evaluated and the position of lead/acid batteries in the medium term for this important market will be assessed.
Measuring competence in endoscopic sinus surgery.
Syme-Grant, J; White, P S; McAleer, J P G
2008-02-01
Competence based education is currently being introduced into higher surgical training in the UK. Valid and reliable performance assessment tools are essential to ensure competencies are achieved. No such tools have yet been reported in the UK literature. We sought to develop and pilot test an Endoscopic Sinus Surgery Competence Assessment Tool (ESSCAT). The ESSCAT was designed for in-theatre assessment of higher surgical trainees in the UK. The ESSCAT rating matrix was developed through task analysis of ESS procedures. All otolaryngology consultants and specialist registrars in Scotland were given the opportunity to contribute to its refinement. Two cycles of in-theatre testing were used to ensure utility and gather quantitative data on validity and reliability. Videos of trainees performing surgery were used in establishing inter-rater reliability. National consultation, the consensus derived minimum standard of performance, Cronbach's alpha = 0.89 and demonstration of trainee learning (p = 0.027) during the in vivo application of the ESSCAT suggest a high level of validity. Inter-rater reliability was moderate for competence decisions (Cohen's Kappa = 0.5) and good for total scores (Intra-Class Correlation Co-efficient = 0.63). Intra-rater reliability was good for both competence decisions (Kappa = 0.67) and total scores (Kendall's Tau-b = 0.73). The ESSCAT generates a valid and reliable assessment of trainees' in-theatre performance of endoscopic sinus surgery. In conjunction with ongoing evaluation of the instrument we recommend the use of the ESSCAT in higher specialist training in otolaryngology in the UK.
NASA Technical Reports Server (NTRS)
Teverovsky, Alexander; Sahu, Kusum
2003-01-01
Potential users of plastic encapsulated microcircuits (PEMs) need to be reminded that unlike the military system of producing robust high-reliability microcircuits that are designed to perform acceptably in a variety of harsh environments, PEMs are primarily designed for use in benign environments where equipment is easily accessed for repair or replacement. The methods of analysis applied to military products to demonstrate high reliability cannot always be applied to PEMs. This makes it difficult for users to characterize PEMs for two reasons: 1. Due to the major differences in design and construction, the standard test practices used to ensure that military devices are robust and have high reliability often cannot be applied to PEMs that have a smaller operating temperature range and are typically more frail and susceptible to moisture absorption. In contrast, high-reliability military microcircuits usually utilize large, robust, high-temperature packages that are hermetically sealed. 2. Unlike the military high-reliability system, users of PEMs have little visibility into commercial manufacturers proprietary design, materials, die traceability, and production processes and procedures. There is no central authority that monitors PEM commercial product for quality, and there are no controls in place that can be imposed across all commercial manufacturers to provide confidence to high-reliability users that a common acceptable level of quality exists for all PEMs manufacturers. Consequently, there is no guaranteed control over the type of reliability that is built into commercial product, and there is no guarantee that different lots from the same manufacturer are equally acceptable. And regarding application, there is no guarantee that commercial products intended for use in benign environments will provide acceptable performance and reliability in harsh space environments. The qualification and screening processes contained in this document are intended to detect poor-quality lots and screen out early random failures from use in space flight hardware. However, since it cannot be guaranteed that quality was designed and built into PEMs that are appropriate for space applications, users cannot screen in quality that may not exist. It must be understood that due to the variety of materials, processes, and technologies used to design and produce PEMs, this test process may not accelerate and detect all failure mechanisms. While the tests herein will increase user confidence that PEMs with otherwise unknown reliability can be used in space environments, such testing may not guarantee the same level of reliability offered by military microcircuits. PEMs should only be used where due to performance needs there are no alternatives in the military high-reliability market, and projects are willing to accept higher risk.
Jalenques, I; Auclair, C; Roblin, J; Morand, D; Tourtauchaux, R; May, R; Vaille-Perret, E; Watts, J; Gerbaud, L; De Leo, D
2013-04-01
To cross-culturally adapt a French version of the LEIPAD, a self-administered questionnaire assessing the health-related quality of life (HRQoL) in adults aged 65 years and over living at home, and to evaluate its psychometric properties. After having translated LEIPAD in accordance with guidelines, we studied psychometric properties: reliability and construct validity-factor analysis, relationships between items and scales, internal consistency, concurrent validity with the Medical Outcome Study Short-Form 36 and known-groups validity. The results obtained in a sample of 195 elderly from the general population showed very good acceptability, with response rates superior to 93 %. Exploratory factor analysis extracted eight factors providing a multidimensionality structure with five misclassifications of items in the seven theoretical scales. Good internal consistency (Cronbach's alpha ranging from 0.73 and 0.86) and strong test-retest reliability (ICCs higher than 0.80 for six scales and 0.70 for one) were demonstrated. Concurrent validity with the SF-36 showed small to strong expected correlations. This first evaluation of the French version of LEIPAD's psychometric properties provides evidence in construct validity and reliability. It would allow HRQoL assessment in clinical and common practice, and investigators would be able to take part in national and international research projects.
The Application of a Residual Risk Evaluation Technique Used for Expendable Launch Vehicles
NASA Technical Reports Server (NTRS)
Latimer, John A.
2009-01-01
This presentation provides a Residual Risk Evaluation Technique (RRET) developed by Kennedy Space Center (KSC) Safety and Mission Assurance (S&MA) Launch Services Division. This technique is one of many procedures used by S&MA at KSC to evaluate residual risks for each Expendable Launch Vehicle (ELV) mission. RRET is a straight forward technique that incorporates the proven methodology of risk management, fault tree analysis, and reliability prediction. RRET derives a system reliability impact indicator from the system baseline reliability and the system residual risk reliability values. The system reliability impact indicator provides a quantitative measure of the reduction in the system baseline reliability due to the identified residual risks associated with the designated ELV mission. An example is discussed to provide insight into the application of RRET.
[Study of the relationship between human quality and reliability].
Long, S; Wang, C; Wang, L i; Yuan, J; Liu, H; Jiao, X
1997-02-01
To clarify the relationship between human quality and reliability, 1925 experiments in 20 subjects were carried out to study the relationship between disposition character, digital memory, graphic memory, multi-reaction time and education level and simulated aircraft operation. Meanwhile, effects of task difficulty and enviromental factor on human reliability were also studied. The results showed that human quality can be predicted and evaluated through experimental methods. The better the human quality, the higher the human reliability.
The psychometric properties of the 5-item gratitude questionnaire in Chinese adolescents.
Zeng, Y; Ling, Y; Huebner, E S; He, Y; Lei, X
2017-05-01
WHAT IS KNOWN ON THE SUBJECT?: The GQ-6 is one of the most widely used self-report questionnaires to evaluate the level of gratitude among adults. The GQ-5 appears suitable for adolescents. WHAT THIS PAPER ADDS TO EXISTING KNOWLEDGE?: We developed a Chinese version of the GQ-5 and examined evidence for its reliability and validity. Results demonstrated adequate reliability and validity, indicating that it is appropriate for the assessment of gratitude in Chinese adolescents. In addition, Chinese early adolescent females reported higher gratitude than adolescent males. WHAT ARE THE IMPLICATIONS FOR PRACTICE?: Screening adolescents who have lower levels of gratitude through the GQ-5 could help identify students who may benefit from empirically validated interventions to promote higher levels of gratitude in an effort to promote positive psychosocial and academic outcomes. Background This study was conducted to evaluate the psychometric properties of the Chinese version of the 5-item Gratitude Questionnaire (GQ-5). Method The sample consisted of 2093 middle school students (46.8% males) in mainland China. Confirmatory factor analysis and multigroup confirmatory factor analysis were performed to examine the factor structure and the measurement equivalence across gender. The convergent validity, Cronbach's α and mean interitem correlations of the GQ-5 were also evaluated. Results The results provided evidence of internal consistency reliability through a Cronbach's α of 0.812 and a mean interitem correlation of 0.463 for the total sample. The results also supported a one-dimensional factor structure. In addition, convergent validity was assessed by statistically significant positive correlations between the GQ-5 and the two subscales of the Children's Hope Scale (CHS) and the Brief Multidimensional Students' Life Satisfaction Scale (BMSLSS) total score. Finally, multigroup confirmatory factor analysis also demonstrated measurement equivalence across gender. Subsequent analyses of latent mean revealed gender differences in early adolescent male and female students. Conclusions The Chinese version of the GQ-5 appears to be a reliable and valid measure of gratitude among Chinese early adolescents. Early adolescent female students reported higher gratitude than early adolescent male students. © 2017 John Wiley & Sons Ltd.
Liang, Wenbin; Binns, Colin; Lee, Andy H; Huang, Rongsheng; Hu, Delong
2008-01-01
In many health studies of the elderly population, the subjects have cognitive or linguistic impairments, so data need to be collected from surrogates. This study compares dietary and lifestyle information reported by elderly Chinese with those provided by their spouses. Community couples 60 years and older were recruited to participate in an interview. One person from each couple was randomly chosen as the index person. Characteristics concerning the index person were then solicited from that person and separately from his or her spouse using validated questionnaires. For the 128 food items considered, the mean kappa was 0.73 for both frequency (SD 0.18) and amount (SD 0.22) of intake, and more than 70% of the couples had kappa statistics exceeding 0.61. Food items exhibiting high agreement between the spouses include rice, apples, tomatoes, and pork chops. The proportion of perfect agreement was higher than 80% for physical activity, smoking, and tea drinking behaviors. In conclusion, the spouse can serve as a proxy to provide reliable information when his or her partner is unavailable.
Moser, Debra K; Riegel, Barbara; McKinley, Sharon; Doering, Lynn V; Meischke, Hendrika; Heo, Seongkum; Lennie, Terry A; Dracup, Kathleen
2009-01-01
Perceived control is a construct with important theoretical and clinical implications for healthcare providers, yet practical application of the construct in research and clinical practice awaits development of an easily administered instrument to measure perceived control with evidence of reliability and validity. To test the psychometric properties of the Control Attitudes Scale-Revised (CAS-R) using a sample of 3,396 individuals with coronary heart disease, 513 patients with acute myocardial infarction, and 146 patients with heart failure. Analyses were done separately in each patient group. Reliability was assessed using Cronbach's alpha to determine internal consistency, and item homogeneity was assessed using item-total and interitem correlations. Validity was examined using principal component analysis and testing hypotheses about known associations. Cronbach's alpha values for the CAS-R in patients with coronary heart disease, acute myocardial infarction, and heart failure were all greater than .70. Item-total and interitem correlation coefficients for all items were acceptable in the groups. In factor analyses, the same single factor was extracted in all groups, and all items were loaded moderately or strongly to the factor in each group. As hypothesized in the final construct validity test, in all groups, patients with higher levels of perceived control had less depression and less anxiety compared with those of patients who had lower levels of perceived control. This study provides evidence of the reliability and validity of the 8-item CAS-R as a measure of perceived control in patients with cardiac illness and provides important insight into a key patient construct.
Golden, Sherita Hill; Sánchez, Brisa N.; DeSantis, Amy S.; Wu, Meihua; Castro, Cecilia; Seeman, Teresa E.; Tadros, Sameh; Shrager, Sandi; Diez Roux, Ana V.
2014-01-01
Collection of salivary cortisol has become increasingly popular in large population-based studies. However, the impact of protocol compliance on day-to-day reliabilities of measures, and the extent to which reliabilities differ systematically according to socio-demographic characteristics, has not been well characterized in large-scale population-based studies to date. Using data on 935 men and women from the Multi-ethnic Study of Atherosclerosis, we investigated whether sampling protocol compliance differs systematically according to socio-demographic factors and whether compliance was associated with cortisol estimates, as well as whether associations of cortisol with both compliance and socio-demographic characteristics were robust to adjustments for one another. We further assessed the day-to-day reliability for cortisol features and the extent to which reliabilities vary according to socio-demographic factors and sampling protocol compliance. Overall, we found higher compliance among persons with higher levels of income and education. Lower compliance was significantly associated with a less pronounced cortisol awakening response (CAR) but was not associated with any other cortisol features, and adjustment for compliance did not affect associations of socio-demographic characteristics with cortisol. Reliability was higher for area under the curve (AUC) and wake up values than for other features, but generally did not vary according to socio-demographic characteristics, with few exceptions. Our findings regarding intra-class correlation coefficients (ICCs) support prior research indicating that multiple day collection is preferable to single day collection, particularly for CAR and slopes, more so than wakeup and AUC. There were few differences in reliability by socio-demographic characteristics. Thus, it is unlikely that group-specific sampling protocols are warranted. PMID:24703168
Validation of the Dementia Care Assessment Packet-Instrumental Activities of Daily Living
Lee, Seok Bum; Park, Jeong Ran; Yoo, Jeong-Hwa; Park, Joon Hyuk; Lee, Jung Jae; Yoon, Jong Chul; Jhoo, Jin Hyeong; Lee, Dong Young; Woo, Jong Inn; Han, Ji Won; Huh, Yoonseok; Kim, Tae Hui
2013-01-01
Objective We aimed to evaluate the psychometric properties of the IADL measure included in the Dementia Care Assessment Packet (DCAP-IADL) in dementia patients. Methods The study involved 112 dementia patients and 546 controls. The DCAP-IADL was scored in two ways: observed score (OS) and predicted score (PS). The reliability of the DCAP-IADL was evaluated by testing its internal consistency, inter-rater reliability and test-retest reliability. Discriminant validity was evaluated by comparing the mean OS and PS between dementia patients and controls by ANCOVA. Pearson or Spearman correlation analysis was performed with other instruments to assess concurrent validity. Receiver operating characteristics curve analysis was performed to examine diagnostic accuracy. Results Chronbach's α coefficients of the DCAP-IADL were above 0.7. The values in dementia patients were much higher (OS=0.917, PS=0.927), indicating excellent degrees of internal consistency. Inter-rater reliabilities and test-retest reliabilities were statistically significant (p<0.05). PS exhibited higher reliabilities than OS. The mean OS and PS of dementia patients were significantly higher than those of the non-demented group after controlling for age, sex and education level. The DCAP-IADL was significantly correlated with other IADL instruments and MMSE-KC (p<0.001). Areas under the curves of the DCAP-IADL were above 0.9. Conclusion The DCAP-IADL is a reliable and valid instrument for evaluating instrumental ability of daily living for the elderly, and may also be useful for screening dementia. Moreover, administering PS may enable the DCAP-IADL to overcome the differences in gender, culture and life style that hinders accurate evaluation of the elderly in previous IADL instruments. PMID:24302946
Joint mobilization forces and therapist reliability in subjects with knee osteoarthritis
Tragord, Bradley S; Gill, Norman W; Silvernail, Jason L; Teyhen, Deydre S; Allison, Stephen C
2013-01-01
Objectives: This study determined biomechanical force parameters and reliability among clinicians performing knee joint mobilizations. Methods: Sixteen subjects with knee osteoarthritis and six therapists participated in the study. Forces were recorded using a capacitive-based pressure mat for three techniques at two grades of mobilization, each with two trials of 15 seconds. Dosage (force–time integral), amplitude, and frequency were also calculated. Analysis of variance was used to analyze grade differences, intraclass correlation coefficients determined reliability, and correlations assessed force associations with subject and rater variables. Results: Grade IV mobilizations produced higher mean forces (P<0.001) and higher dosage (P<0.001), while grade III produced higher maximum forces (P = 0.001). Grade III forces (Newtons) by technique (mean, maximum) were: extension 48, 81; flexion 41, 68; and medial glide 21, 34. Grade IV forces (Newtons) by technique (mean, maximum) were: extension 58, 78; flexion 44, 60; and medial glide 22, 30. Frequency (Hertz) ranged between 0.9–1.1 (grade III) and 1.4–1.6 (grade IV). Intra-clinician reliability was excellent (>0.90). Inter-clinician reliability was moderate for force and dosage, and poor for amplitude and frequency. Discussion: Force measurements were consistent with previously reported ranges and clinical constructs. Grade III and grade IV mobilizations can be distinguished from each other with differences for force and frequency being small, and dosage and amplitude being large. Intra-clinician reliability was excellent for all biomechanical parameters and inter-clinician reliability for dosage, the main variable of clinical interest, was moderate. This study quantified the applied forces among multiple clinicians, which may help determine optimal dosage and standardize care. PMID:24421632
Role stress among auxiliary nurses midwives in Gujarat, India.
Purohit, Bhaskar; Vasava, Paul
2017-01-23
Understanding Role Stress is important as health service providers, especially nurses experience high levels of Role Stress which is linked to burnout, poor quality of care and high turnover. The current study explicates the concept of Role Stress and assesses the Role Stress experienced by the Auxiliary Nurse Midwives (ANMs) working with rural government health centres from Gujarat, India. The study included 84 ANMs working with government health centres from one district in India. A structured instrument with established reliability and validity was used to measure 10 dimensions of Role Stress namely: Inter-role distance, role stagnation, role expectation conflict, role erosion: role overload, role isolation, personal inadequacy, self-role distance, role ambiguity and resource inadequacy. The study instrument was based on 5 point Likert rating scale that contained 50 unidirectional negative statements, 5 for each dimension. Kolmogorov-Smirnov and Shapiro-Wilk test were carried out to assess if the data were normally distributed. Cronbach's alpha test was carried out to assess reliability of the instrument. The study data was analyzed using descriptive statistics mainly using mean scores with higher scores indicating higher Role Stress and vice versa. The data was analyzed using SPSS version 19. Kolmogorov-Smirnov and Shapiro-Wilk test indicated that the data were normally distributed. Cronbach's alpha test indicated values of 0.852 suggesting high reliability of the tool. The highest Role Stress among ANMs was experienced for resource inadequacy. Role overload, role stagnation and inter-role distance were among the other important role stressors for ANMs. The study results suggests that ANMs frequently feel that: they do not have adequate amount of resources, facilities and financial support from the high levels authorities; people have too many expectations from their roles and as result they are overloaded with work and have very limited opportunities for future growth. The current study has the potential to provide a useful and a comprehensive framework to understand the Role Stress among the health service providers that could be further useful in designing interventions specifically aimed at reducing Role Stress in order to prevent burnout thereby addressing the productivity and retention.
Test-Retest Reliability of Innovated Strength Tests for Hip Muscles
Meyer, Christophe; Corten, Kristoff; Wesseling, Mariska; Peers, Koen; Simon, Jean-Pierre; Jonkers, Ilse; Desloovere, Kaat
2013-01-01
The burden of hip muscles weakness and its relation to other impairments has been well documented. It is therefore a pre-requisite to have a reliable method for clinical assessment of hip muscles function allowing the design and implementation of a proper strengthening program. Motor-driven dynamometry has been widely accepted as the gold-standard for lower limb muscle strength assessment but is mainly related to the knee joint. Studies focusing on the hip joint are less exhaustive and somewhat discrepant with regard to optimal participants position, consequently influencing outcome measures. Thus, we aimed to develop a standardized test setup for the assessment of hip muscles strength, i.e. flexors/extensors and abductors/adductors, with improved participant stability and to define its psychometric characteristics. Eighteen participants performed unilateral isokinetic and isometric contractions of the hip muscles in the sagittal and coronal plane at two separate occasions. Peak torque and normalized peak torque were measured for each contraction. Relative and absolute measures of reliability were calculated using the intraclass correlation coefficient and standard error of measurement, respectively. Results from this study revealed higher levels of between-day reliability of isokinetic/isometric hip abduction/flexion peak torque compared to existing literature. The least reliable measures were found for hip extension and adduction, which could be explained by a less efficient stabilization technique. Our study additionally provided a first set of reference normalized data which can be used in future research. PMID:24260550
NASA Astrophysics Data System (ADS)
Contractor, S.; Donat, M.; Alexander, L. V.
2017-12-01
Reliable observations of precipitation are necessary to determine past changes in precipitation and validate models, allowing for reliable future projections. Existing gauge based gridded datasets of daily precipitation and satellite based observations contain artefacts and have a short length of record, making them unsuitable to analyse precipitation extremes. The largest limiting factor for the gauge based datasets is a dense and reliable station network. Currently, there are two major data archives of global in situ daily rainfall data, first is Global Historical Station Network (GHCN-Daily) hosted by National Oceanic and Atmospheric Administration (NOAA) and the other by Global Precipitation Climatology Centre (GPCC) part of the Deutsche Wetterdienst (DWD). We combine the two data archives and use automated quality control techniques to create a reliable long term network of raw station data, which we then interpolate using block kriging to create a global gridded dataset of daily precipitation going back to 1950. We compare our interpolated dataset with existing global gridded data of daily precipitation: NOAA Climate Prediction Centre (CPC) Global V1.0 and GPCC Full Data Daily Version 1.0, as well as various regional datasets. We find that our raw station density is much higher than other datasets. To avoid artefacts due to station network variability, we provide multiple versions of our dataset based on various completeness criteria, as well as provide the standard deviation, kriging error and number of stations for each grid cell and timestep to encourage responsible use of our dataset. Despite our efforts to increase the raw data density, the in situ station network remains sparse in India after the 1960s and in Africa throughout the timespan of the dataset. Our dataset would allow for more reliable global analyses of rainfall including its extremes and pave the way for better global precipitation observations with lower and more transparent uncertainties.
Test Assembly Implications for Providing Reliable and Valid Subscores
ERIC Educational Resources Information Center
Lee, Minji K.; Sweeney, Kevin; Melican, Gerald J.
2017-01-01
This study investigates the relationships among factor correlations, inter-item correlations, and the reliability estimates of subscores, providing a guideline with respect to psychometric properties of useful subscores. In addition, it compares subscore estimation methods with respect to reliability and distinctness. The subscore estimation…
Park, Jung-Keun; Boyer, Jon; Tessler, Jamie; Casey, Jeffrey; Schemm, Linda; Gore, Rebecca; Punnett, Laura
2009-07-01
This study examined the inter-rater reliability of expert observations of ergonomic risk factors by four analysts. Ten jobs were observed at a hospital using a newly expanded version of the PATH method (Buchholz et al. 1996), to which selected upper extremity exposures had been added. Two of the four raters simultaneously observed each worker onsite for a total of 443 observation pairs containing 18 categorical exposure items each. For most exposure items, kappa coefficients were 0.4 or higher. For some items, agreement was higher both for the jobs with less rapid hand activity and for the analysts with a higher level of ergonomic job analysis experience. These upper extremity exposures could be characterised reliably with real-time observation, given adequate experience and training of the observers. The revised version of PATH is applicable to the analysis of jobs where upper extremity musculoskeletal strain is of concern.
The Fertility Problem Inventory: measuring perceived infertility-related stress.
Newton, C R; Sherrard, W; Glavac, I
1999-07-01
To develop a reliable, valid instrument to evaluate perceived infertility-related stress. Prospective study. University-affiliated teaching hospital. Consecutively referred patients (1,153 women and 1,149 men) seen for infertility treatment. None. Participants' infertility-related stress was assessed by written questionnaire using the Fertility Problem Inventory. Current levels of anxiety, depression, and marital satisfaction also were determined. Women described greater global stress than men and higher specific stress in terms of social concerns, sexual concerns, and need for parenthood. Both men and women facing male infertility reported higher global stress and more social and sexual concerns than men and women experiencing female infertility. Social, sexual, and relationship concerns related to infertility were more effective predictors of depression and marital dissatisfaction than expressed needs for parenthood or attitudes toward child-free living. The Fertility Problem Inventory provides a reliable measure of perceived infertility-related stress and specific information on five separate domains of patient concern. Patterns of infertility-related stress differed depending on gender, fertility history, and infertility diagnosis. Among patients receiving treatment, social, sexual, and relationship concerns appear central to current distress. Counseling interventions that target these domains appear likely to offer maximal therapeutic benefit.
NASA Technical Reports Server (NTRS)
Smith, Bryan K.; Nazario, Margaret L.; Manzella, David H.
2012-01-01
Solar Electric Propulsion has evolved into a demonstrated operational capability performing station keeping for geosynchronous satellites, enabling challenging deep-space science missions, and assisting in the transfer of satellites from an elliptical orbit Geostationary Transfer Orbit (GTO) to a Geostationary Earth Orbit (GEO). Advancing higher power SEP systems will enable numerous future applications for human, robotic, and commercial missions. These missions are enabled by either the increased performance of the SEP system or by the cost reductions when compared to conventional chemical propulsion systems. Higher power SEP systems that provide very high payload for robotic missions also trade favorably for the advancement of human exploration beyond low Earth orbit. Demonstrated reliable systems are required for human space flight and due to their successful present day widespread use and inherent high reliability, SEP systems have progressively become a viable entrant into these future human exploration architectures. NASA studies have identified a 30 kW-class SEP capability as the next appropriate evolutionary step, applicable to wide range of both human and robotic missions. This paper describes the planning options, mission applications, and technology investments for representative 30kW-class SEP mission concepts under consideration by NASA
Hybrid RAID With Dual Control Architecture for SSD Reliability
NASA Astrophysics Data System (ADS)
Chatterjee, Santanu
2010-10-01
The Solid State Devices (SSD) which are increasingly being adopted in today's data storage Systems, have higher capacity and performance but lower reliability, which leads to more frequent rebuilds and to a higher risk. Although SSD is very energy efficient compared to Hard Disk Drives but Bit Error Rate (BER) of an SSD require expensive erase operations between successive writes. Parity based RAID (for Example RAID4,5,6)provides data integrity using parity information and supports losing of any one (RAID4, 5)or two drives(RAID6), but the parity blocks are updated more often than the data blocks due to random access pattern so SSD devices holding more parity receive more writes and consequently age faster. To address this problem, in this paper we propose a Model based System of hybrid disk array architecture in which we plan to use RAID 4(Stripping with Parity) technique and SSD drives as Data drives while any fastest Hard disk drives of same capacity can be used as dedicated parity drives. By this proposed architecture we can open the door to using commodity SSD's past their erasure limit and it can also reduce the need for expensive hardware Error Correction Code (ECC) in the devices.
Attending to weak signals: the leader's challenge.
Kerfoot, Karlene
2005-12-01
Halverson and Isham (2003) quote sources that report the accidental death rate of simply being in a hospital is " ... four hundred times more likely than your risk of death from traveling by train, forty times higher than driving a car, and twenty times higher than flying in a commercial aircraft" (p. 13). High-reliability organizations such as nuclear power plants and aircraft carriers have been pioneers in the business of recognizing weak signals. Weike and Sutcliffe (2001) note that high-reliability organizations distinguish themselves from others because of their mindfulness which enables them to see the significance of weak signals and to give strong interventions to weak signals. To act mindfully, these organizations have an underlying mental model of continually updating, anticipating, and focusing the possibility of failure using the intelligence that weak signals provides. Much of what happens is unexpected in health care. However, with a culture that is continually looking for weak signals, and intervenes and rescues when these signals are detected, the unexpected happens less often. This is the epitome of how leaders can build a culture of safety that focuses on recognizing the weak signals to manage the unforeseen.
Attending to weak signals: the leader's challenge.
Kerfoot, Karlene
2004-01-01
Halverson and Isham (2003) quote sources that report the accidental death rate of simply being in a hospital is "... four hundred times more likely than your risk of death from traveling by train, forty times higher than driving a car, and twenty times higher than flying in a commercial aircraft" (p. 13). High-reliability organizations such as nuclear power plants and aircraft carriers have been pioneers in the business of recognizing weak signals. Weike and Sutcliffe (2001) note that high-reliability organizations distinguish themselves from others because of their mindfulness which enables them to see the significance of weak signals and to give strong interventions to weak signals. To act mindfully, these organizations have an underlying mental model of continually updating, anticipating, and focusing the possibility of failure using the intelligence that weak signals provides. Much of what happens is unexpected in health care. However, with a culture that is continually looking for weak signals, and intervenes and rescues when these signals are detected, the unexpected happens less often. This is the epitome of how leaders can build a culture of safety that focuses on recognizing the weak signals to manage the unforeseen.
Attending to weak signals: the leader's challenge.
Kerfoot, Karlene
2003-01-01
Halverson and Isham (2003) quote sources that report the accidental death rate of simply being in a hospital is "...four hundred times more likely than your risk of death from traveling by train, forty times higher than driving a car, and twenty times higher than flying in a commercial aircraft" (p. 13). High-reliability organizations such as nuclear power plants and aircraft carriers have been pioneers in the business of recognizing weak signals. Weike and Sutcliffe (2001) note that high-reliability organizations distinguish themselves from others because of their mindfulness which enables them to see the significance of weak signals and to give strong interventions to weak signals. To act mindfully, these organizations have an underlying mental model of continually updating, anticipating, and focusing the possibility of failure using the intelligence that weak signals provides. Much of what happens is unexpected in health care. However, with a culture that is continually looking for weak signals, and intervenes and rescues when these signals are detected, the unexpected happens less often. This is the epitome of how leaders can build a culture of safety that focuses on recognizing the weak signals to manage the unforeseen.
Propulsion System Advances that Enable a Reusable Liquid Fly Back Booster (LFBB)
NASA Technical Reports Server (NTRS)
Keith, Edward L.; Rothschild, William J.
1998-01-01
This paper provides an overview of the booster propulsion system for the Liquid Fly Back Booster (LFBB). This includes, system requirements, design approach, concept of operations, reliability, safety and cost assumptions. The paper summarizes the findings of the Boeing propulsion team that has been studying the LFBB feasibility as a booster replacement for the Space Shuttle. This paper will discuss recent advances including a new generation of kerosene and oxygen rich pre-burner staged combustion cycle main rocket engines. The engine reliability and safety is expected to be much higher than current standards by adding extra operating margins into the design and normally operating the engines at 75% of engine rated power. This allows for engine out capability. The new generation of main engines operates at significantly higher chamber pressure than the prior generation of gas generator cycle engines. The oxygen rich pre-burner engine cycle, unlike the fuel rich gas generator cycle, results in internally self-cleaning firings which facilitates reusability. Maintenance is further enhanced with integrated health monitoring to improve safety and turn-around efficiency. The maintainability of the LFBB LOX / kerosene engines is being improved by designing the vehicle/engine interfaces for easy access to key engine components.
Propulsion system advances that enable a reusable Liquid Fly Back Booster (LFBB)
NASA Technical Reports Server (NTRS)
Keith, E. L.; Rothschild, W. J.
1998-01-01
This paper provides an overview of the booster propulsion system for the Liquid Fly Back Booster (LFBB). This includes, system requirements, design approach, concept of operations, reliability, safety and cost assumptions. The paper summarizes the findings of the Boeing propulsion team that has been studying the LFBB feasibility as a booster replacement for the Space Shuttle. This paper will discuss recent advances including a new generation of kerosene and oxygen rich pre-burner staged combustion cycle main rocket engines. The engine reliability and safety is expected to be much higher than current standards by adding extra operating margins into the design and normally operating the engines at 75% of engine rated power. This allows for engine out capability. The new generation of main engines operates at significantly higher chamber pressure than the prior generation of gas generator cycle engines. The oxygen rich pre-burner engine cycle, unlike the fuel rich gas generator cycle, results in internally self-cleaning firings which facilitates reusability. Maintenance is further enhanced with integrated health monitoring to improve safety and turn-around efficiency. The maintainability of the LFBB LOX/kerosene engines is being improved by designing the vehicle/engine interfaces for easy access to key engine components.
Diagnosing Femoroacetabular Impingement From Plain Radiographs
Ayeni, Olufemi R.; Chan, Kevin; Whelan, Daniel B.; Gandhi, Rajiv; Williams, Dale; Harish, Srinivasan; Choudur, Hema; Chiavaras, Mary M.; Karlsson, Jon; Bhandari, Mohit
2014-01-01
Background: A diagnosis of femoroacetabular impingement (FAI) requires careful history and physical examination, as well as an accurate and reliable radiologic evaluation using plain radiographs as a screening modality. Radiographic markers in the diagnosis of FAI are numerous and not fully validated. In particular, reliability in their assessment across health care providers is unclear. Purpose: To determine inter- and intraobserver reliability between orthopaedic surgeons and musculoskeletal radiologists. Study Design: Cohort study (diagnosis); Level of evidence, 3. Methods: Six physicians (3 orthopaedic surgeons, 3 musculoskeletal radiologists) independently evaluated a broad spectrum of FAI pathologies across 51 hip radiographs on 2 occasions separated by at least 4 weeks. Reviewers used 8 common criteria to diagnose FAI, including (1) pistol-grip deformity, (2) size of alpha angle, (3) femoral head-neck offset, (4) posterior wall sign abnormality, (5) ischial spine sign abnormality, (6) coxa profunda abnormality, (7) crossover sign abnormality, and (8) acetabular protrusion. Agreement was calculated using the intraclass correlation coefficient (ICC). Results: When establishing an FAI diagnosis, there was poor interobserver reliability between the surgeons and radiologists (ICC batch 1 = 0.33; ICC batch 2 = 0.15). In contrast, there was higher interobserver reliability within each specialty, ranging from fair to good (surgeons: ICC batch 1 = 0.72; ICC batch 2 = 0.70 vs radiologists: ICC batch 1 = 0.59; ICC batch 2 = 0.74). Orthopaedic surgeons had the highest interobserver reliability when identifying pistol-grip deformities (ICC = 0.81) or abnormal alpha angles (ICC = 0.81). Similarly, radiologists had the highest agreement for detecting pistol-grip deformities (ICC = 0.75). Conclusion: These results suggest that surgeons and radiologists agree among themselves, but there is a need to improve the reliability of radiographic interpretations for FAI between the 2 specialties. The observed degree of low reliability may ultimately lead to missed, delayed, or inappropriate treatments for patients with symptomatic FAI. PMID:26535344
Performance of salmon fishery portfolios across western North America.
Griffiths, Jennifer R; Schindler, Daniel E; Armstrong, Jonathan B; Scheuerell, Mark D; Whited, Diane C; Clark, Robert A; Hilborn, Ray; Holt, Carrie A; Lindley, Steven T; Stanford, Jack A; Volk, Eric C
2014-12-01
Quantifying the variability in the delivery of ecosystem services across the landscape can be used to set appropriate management targets, evaluate resilience and target conservation efforts. Ecosystem functions and services may exhibit portfolio-type dynamics, whereby diversity within lower levels promotes stability at more aggregated levels. Portfolio theory provides a framework to characterize the relative performance among ecosystems and the processes that drive differences in performance. We assessed Pacific salmon Oncorhynchus spp. portfolio performance across their native latitudinal range focusing on the reliability of salmon returns as a metric with which to assess the function of salmon ecosystems and their services to humans. We used the Sharpe ratio (e.g. the size of the total salmon return to the portfolio relative to its variability (risk)) to evaluate the performance of Chinook and sockeye salmon portfolios across the west coast of North America. We evaluated the effects on portfolio performance from the variance of and covariance among salmon returns within each portfolio, and the association between portfolio performance and watershed attributes. We found a positive latitudinal trend in the risk-adjusted performance of Chinook and sockeye salmon portfolios that also correlated negatively with anthropogenic impact on watersheds (e.g. dams and land-use change). High-latitude Chinook salmon portfolios were on average 2·5 times more reliable, and their portfolio risk was mainly due to low variance in the individual assets. Sockeye salmon portfolios were also more reliable at higher latitudes, but sources of risk varied among the highest performing portfolios. Synthesis and applications . Portfolio theory provides a straightforward method for characterizing the resilience of salmon ecosystems and their services. Natural variability in portfolio performance among undeveloped watersheds provides a benchmark for restoration efforts. Locally and regionally, assessing the sources of portfolio risk can guide actions to maintain existing resilience (protect habitat and disturbance regimes that maintain response diversity; employ harvest strategies sensitive to different portfolio components) or improve restoration activities. Improving our understanding of portfolio reliability may allow for management of natural resources that is robust to ongoing environmental change. Portfolio theory provides a straightforward method for characterizing the resilience of salmon ecosystems and their services. Natural variability in portfolio performance among undeveloped watersheds provides a benchmark for restoration efforts. Locally and regionally, assessing the sources of portfolio risk can guide actions to maintain existing resilience (protect habitat and disturbance regimes that maintain response diversity; employ harvest strategies sensitive to different portfolio components) or improve restoration activities. Improving our understanding of portfolio reliability may allow for management of natural resources that is robust to ongoing environmental change.
Performance of salmon fishery portfolios across western North America
Griffiths, Jennifer R; Schindler, Daniel E; Armstrong, Jonathan B; Scheuerell, Mark D; Whited, Diane C; Clark, Robert A; Hilborn, Ray; Holt, Carrie A; Lindley, Steven T; Stanford, Jack A; Volk, Eric C
2014-01-01
Quantifying the variability in the delivery of ecosystem services across the landscape can be used to set appropriate management targets, evaluate resilience and target conservation efforts. Ecosystem functions and services may exhibit portfolio-type dynamics, whereby diversity within lower levels promotes stability at more aggregated levels. Portfolio theory provides a framework to characterize the relative performance among ecosystems and the processes that drive differences in performance. We assessed Pacific salmon Oncorhynchus spp. portfolio performance across their native latitudinal range focusing on the reliability of salmon returns as a metric with which to assess the function of salmon ecosystems and their services to humans. We used the Sharpe ratio (e.g. the size of the total salmon return to the portfolio relative to its variability (risk)) to evaluate the performance of Chinook and sockeye salmon portfolios across the west coast of North America. We evaluated the effects on portfolio performance from the variance of and covariance among salmon returns within each portfolio, and the association between portfolio performance and watershed attributes. We found a positive latitudinal trend in the risk-adjusted performance of Chinook and sockeye salmon portfolios that also correlated negatively with anthropogenic impact on watersheds (e.g. dams and land-use change). High-latitude Chinook salmon portfolios were on average 2·5 times more reliable, and their portfolio risk was mainly due to low variance in the individual assets. Sockeye salmon portfolios were also more reliable at higher latitudes, but sources of risk varied among the highest performing portfolios. Synthesis and applications. Portfolio theory provides a straightforward method for characterizing the resilience of salmon ecosystems and their services. Natural variability in portfolio performance among undeveloped watersheds provides a benchmark for restoration efforts. Locally and regionally, assessing the sources of portfolio risk can guide actions to maintain existing resilience (protect habitat and disturbance regimes that maintain response diversity; employ harvest strategies sensitive to different portfolio components) or improve restoration activities. Improving our understanding of portfolio reliability may allow for management of natural resources that is robust to ongoing environmental change. Portfolio theory provides a straightforward method for characterizing the resilience of salmon ecosystems and their services. Natural variability in portfolio performance among undeveloped watersheds provides a benchmark for restoration efforts. Locally and regionally, assessing the sources of portfolio risk can guide actions to maintain existing resilience (protect habitat and disturbance regimes that maintain response diversity; employ harvest strategies sensitive to different portfolio components) or improve restoration activities. Improving our understanding of portfolio reliability may allow for management of natural resources that is robust to ongoing environmental change. PMID:25552746
Method to Increase Performance of Foil Bearings Through Passive Thermal Management
NASA Technical Reports Server (NTRS)
Bruckner, Robert
2013-01-01
This invention is a new approach to designing foil bearings to increase their load capacity and improve their reliability through passive thermal management. In the present case, the bearing is designed in such a way as to prevent the carryover of lubricant from the exit of one sector to the inlet of the ensuing sector of the foil bearing. When such passive thermal management techniques are used, bearing load capacity is improved by multiples, and reliability is enhanced when compared to current foil bearings. This concept has recently been tested and validated, and shows that load capacity performance of foil bearings can be improved by a factor of two at relatively low speeds with potentially greater relative improvements at higher speeds. Such improvements in performance with respect to speed are typical of foil bearings. Additionally, operation of these newly conceived bearings shows much more reliability and repeatable performance. This trait can be exploited in machine design to enhance safety, reliability, and overall performance. Finally, lower frictional torque has been demonstrated when operating at lower (non-load capacity) loads, thus providing another improvement above the current state of the art. The objective of the invention is to incorporate features into a foil bearing that both enhance passive thermal management and temperature control, while at the same time improve the hydrodynamic (load capacity) performance of the foil bearing. Foil bearings are unique antifriction devices that can utilize the working fluid of a machine as a lubricant (typically air for turbines and motors, liquids for pumps), and as a coolant to remove excess energy due to frictional heating. The current state of the art of foil bearings utilizes forced cooling of the bearing and shaft, which represents poor efficiency and poor reliability. This invention embodies features that utilize the bearing geometry in such a manner as to both support load and provide an inherent and passive cooling mechanism. This cooling mechanism functions in such a way as to prevent used (higher temperature) lubricant from being carried over from the exit of one sector into the entry of the next sector of the foil bearing. The disclosed innovation is an improved foil bearing design that reduces or eliminates the need for force cooling of the bearing, while at the same time improving the load capacity of the bearing by at least a factor of two. These improvements are due to the elimination of lubricant carryover from the trailing edge of one sector into the leading edge of the next, and the mixing of used lubricant with the surrounding ambient fluid.
Odgers, Candice L.; Caspi, Avshalom; Bates, Christopher J.; Sampson, Robert J.; Moffitt, Terrie E.
2012-01-01
Background Children growing up in poor versus affluent neighborhoods are more likely to spend time in prison, develop health problems and die at an early age. The question of how neighborhood conditions influence our behavior and health has attracted the attention of public health officials and scholars for generations. Online tools are now providing new opportunities to measure neighborhood features and may provide a cost effective way to advance our understanding of neighborhood effects on child health. Method A virtual systematic social observation (SSO) study was conducted to test whether Google Street View could be used to reliably capture the neighborhood conditions of families participating in the Environmental-Risk (E-Risk) Longitudinal Twin Study. Multiple raters coded a subsample of 120 neighborhoods and convergent and discriminant validity was evaluated on the full sample of over 1,000 neighborhoods by linking virtual SSO measures to: (a) consumer based geo-demographic classifications of deprivation and health, (b) local resident surveys of disorder and safety, and (c) parent and teacher assessments of children’s antisocial behavior, prosocial behavior, and body mass index. Results High levels of observed agreement were documented for signs of physical disorder, physical decay, dangerousness and street safety. Inter-rater agreement estimates fell within the moderate to substantial range for all of the scales (ICCs ranged from .48 to .91). Negative neighborhood features, including SSO-rated disorder and decay and dangerousness corresponded with local resident reports, demonstrated a graded relationship with census-defined indices of socioeconomic status, and predicted higher levels of antisocial behavior among local children. In addition, positive neighborhood features, including SSO-rated street safety and the percentage of green space, were associated with higher prosocial behavior and healthy weight status among children. Conclusions Our results support the use of Google Street View as a reliable and cost effective tool for measuring both negative and positive features of local neighborhoods. PMID:22676812
Odgers, Candice L; Caspi, Avshalom; Bates, Christopher J; Sampson, Robert J; Moffitt, Terrie E
2012-10-01
Children growing up in poor versus affluent neighborhoods are more likely to spend time in prison, develop health problems and die at an early age. The question of how neighborhood conditions influence our behavior and health has attracted the attention of public health officials and scholars for generations. Online tools are now providing new opportunities to measure neighborhood features and may provide a cost effective way to advance our understanding of neighborhood effects on child health. A virtual systematic social observation (SSO) study was conducted to test whether Google Street View could be used to reliably capture the neighborhood conditions of families participating in the Environmental-Risk (E-Risk) Longitudinal Twin Study. Multiple raters coded a subsample of 120 neighborhoods and convergent and discriminant validity was evaluated on the full sample of over 1,000 neighborhoods by linking virtual SSO measures to: (a) consumer based geo-demographic classifications of deprivation and health, (b) local resident surveys of disorder and safety, and (c) parent and teacher assessments of children's antisocial behavior, prosocial behavior, and body mass index. High levels of observed agreement were documented for signs of physical disorder, physical decay, dangerousness and street safety. Inter-rater agreement estimates fell within the moderate to substantial range for all of the scales (ICCs ranged from .48 to .91). Negative neighborhood features, including SSO-rated disorder and decay and dangerousness corresponded with local resident reports, demonstrated a graded relationship with census-defined indices of socioeconomic status, and predicted higher levels of antisocial behavior among local children. In addition, positive neighborhood features, including SSO-rated street safety and the percentage of green space, were associated with higher prosocial behavior and healthy weight status among children. Our results support the use of Google Street View as a reliable and cost effective tool for measuring both negative and positive features of local neighborhoods. © 2012 The Authors. Journal of Child Psychology and Psychiatry © 2012 Association for Child and Adolescent Mental Health.
Reviewing Reliability and Validity of Information for University Educational Evaluation
NASA Astrophysics Data System (ADS)
Otsuka, Yusaku
To better utilize evaluations in higher education, it is necessary to share the methods of reviewing reliability and validity of examination scores and grades, and to accumulate and share data for confirming results. Before the GPA system is first introduced into a university or college, the reliability of examination scores and grades, especially for essay examinations, must be assured. Validity is a complicated concept, so should be assured in various ways, including using professional audits, theoretical models, and statistical data analysis. Because individual students and teachers are continually improving, using evaluations to appraise their progress is not always compatible with using evaluations in appraising the implementation of accountability in various departments or the university overall. To better utilize evaluations and improve higher education, evaluations should be integrated into the current system by sharing the vision of an academic learning community and promoting interaction between students and teachers based on sufficiently reliable and validated evaluation tools.
Ocular Vestibular Evoked Myogenic Potentials in Response to Three Test Positions and Two Frequencies
Todai, Janvi K.; Congdon, Sharon L.; Sangi-Haghpeykar, Haleh; Cohen, Helen S.
2014-01-01
Objective To determine how eye closure, test positions, and stimulus frequencies influence ocular vestibular evoked myogenic potentials. Study Design This study used a within-subjects repeated measures design. Methods Twenty asymptomatic subjects were each tested on ocular vestibular evoked myogenic potentials in three head/eye conditions at 500 Hz and 1000 Hz using air-conducted sound: 1) Sitting upright, head erect, eyes open, looking up. 2) Lying supine, neck flexed 30 degrees, eyes open and looking up. 3) Lying supine, neck flexed 30 degrees, eyes closed and relaxed. Four dependent variables measured were n10, p16, amplitude, and threshold. Results The supine position/ eyes open was comparable to sitting/ eyes open and better than supine/ eyes closed. Eyes closed resulted in lower amplitude, higher threshold, and prolonged latency. Significantly fewer subjects provided responses with eyes closed than with eyes open. No significant differences were found between both eyes open conditions. Both n10 and p16 were lower at 1000 Hz than at 500 Hz. Amplitude and threshold were higher at 1000 Hz than at 500 Hz. Conclusion Supine eyes open is a reliable alternative to sitting eyes open in patients who cannot maintain a seated position. Testing at 1000 Hz provides a larger response with a faster onset that fatigues faster than at 500 Hz. The increased variability and decreased response in the eyes closed position suggest that the eyes closed position is not reliable. PMID:24178911
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2009-01-01
The design and mass cost of a starship and its life support system are investigated. The mission plan for a multi generational interstellar voyage to colonize a new planet is used to describe the starship design, including the crew habitat, accommodations, and life support. Only current technology is assumed. Highly reliable life support systems can be provided with reasonably small additional mass, suggesting that they can support long duration missions. Bioregenerative life support, growing crop plants that provide food, water, and oxygen, has been thought to need less mass than providing stored food for long duration missions. The large initial mass of hydroponics systems is paid for over time by saving the mass of stored food. However, the yearly logistics mass required to support a bioregenerative system exceeds the mass of food solids it produces, so that supplying stored dehydrated food always requires less mass than bioregenerative food production. A mixed system that grows about half the food and supplies the other half dehydrated has advantages that allow it to breakeven with stored dehydrated food in about 66 years. However, moderate increases in the hydroponics system mass to achieve high reliability, such as adding spares that double the system mass and replacing the initial system every 100 years, increase the mass cost of bioregenerative life support. In this case, the high reliability half food growing, half food supplying system does not breakeven for 389 years. An even higher reliability half and half system, with three times original system mass and replacing the system every 50 years, never breaks even. Growing food for starship life support requires more mass than providing dehydrated food, even for multigeneration voyages of hundreds of years. The benefits of growing some food may justify the added mass cost. Much more efficient recycling food production is wanted but may not be possible. A single multigenerational interstellar voyage to colonize a new planet would have cost similar to that of the Apollo program. Cost is reduced if a small crew travels slowly and lands with minimal equipment. We can go to the stars!
Availability Improvement of Layer 2 Seamless Networks Using OpenFlow
Molina, Elias; Jacob, Eduardo; Matias, Jon; Moreira, Naiara; Astarloa, Armando
2015-01-01
The network robustness and reliability are strongly influenced by the implementation of redundancy and its ability of reacting to changes. In situations where packet loss or maximum latency requirements are critical, replication of resources and information may become the optimal technique. To this end, the IEC 62439-3 Parallel Redundancy Protocol (PRP) provides seamless recovery in layer 2 networks by delegating the redundancy management to the end-nodes. In this paper, we present a combination of the Software-Defined Networking (SDN) approach and PRP topologies to establish a higher level of redundancy and thereby, through several active paths provisioned via the OpenFlow protocol, the global reliability is increased, as well as data flows are managed efficiently. Hence, the experiments with multiple failure scenarios, which have been run over the Mininet network emulator, show the improvement in the availability and responsiveness over other traditional technologies based on a single active path. PMID:25759861
Availability improvement of layer 2 seamless networks using OpenFlow.
Molina, Elias; Jacob, Eduardo; Matias, Jon; Moreira, Naiara; Astarloa, Armando
2015-01-01
The network robustness and reliability are strongly influenced by the implementation of redundancy and its ability of reacting to changes. In situations where packet loss or maximum latency requirements are critical, replication of resources and information may become the optimal technique. To this end, the IEC 62439-3 Parallel Redundancy Protocol (PRP) provides seamless recovery in layer 2 networks by delegating the redundancy management to the end-nodes. In this paper, we present a combination of the Software-Defined Networking (SDN) approach and PRP topologies to establish a higher level of redundancy and thereby, through several active paths provisioned via the OpenFlow protocol, the global reliability is increased, as well as data flows are managed efficiently. Hence, the experiments with multiple failure scenarios, which have been run over the Mininet network emulator, show the improvement in the availability and responsiveness over other traditional technologies based on a single active path.
Measuring awareness of financial skills: reliability and validity of a new measure.
Cramer, K; Tuokko, H A; Mateer, C A; Hultsch, D F
2004-03-01
This paper examines the psychometric properties of a three-part (participant, informant, and performance) Measure for assessing Awareness of Financial Skills (MAFS). The MAFS was administered to 10 seniors with dementia and 25 well-functioning seniors, and their informants. Measures of cognitive functioning, social desirability, neuroticism, and perceived control were administered to each participant to allow for an assessment of validity. Internal consistency estimates for the participant and informant questionnaires were found to be 0.92 and 0.97, respectively. Convergent validity analysis indicated that performance on this measure was related to level of cognitive functioning, with higher level of unawareness associated with decreased cognitive ability. Discriminant validity analysis showed that performance on this measure was not related to social desirability or neuroticism. This study provides evidence that the MAFS is a reliable and valid tool for assessing awareness of financial skills in older adults.
Photo- and electroproduction of K+Λ with a unitarity-restored isobar model
NASA Astrophysics Data System (ADS)
Skoupil, D.; Bydžovský, P.
2018-02-01
Exploiting the isobar model, kaon photo- and electroproduction on the proton in the resonance region comes under scrutiny. An upgrade of our previous model, comprising higher-spin nucleon and hyperon exchanges in the consistent formalism, was accomplished by implementing energy-dependent widths of nucleon resonances, which leads to a different choice of hadron form factor with much softer values of cutoff parameter for the resonant part. For a reliable description of electroproduction, the necessity of including longitudinal couplings of nucleon resonances to virtual photons was revealed. We present a new model whose free parameters were adjusted to photo- and electroproduction data and which provides a reliable overall description of experimental data in all kinematic regions. The majority of nucleon resonances chosen in this analysis coincide with those selected in our previous analysis and also in the Bayesian analysis with the Regge-plus-resonance model as the states contributing to this process with the highest probability.
Item response theory analysis of the Lichtenberg Financial Decision Screening Scale.
Teresi, Jeanne A; Ocepek-Welikson, Katja; Lichtenberg, Peter A
2017-01-01
The focus of these analyses was to examine the psychometric properties of the Lichtenberg Financial Decision Screening Scale (LFDSS). The purpose of the screen was to evaluate the decisional abilities and vulnerability to exploitation of older adults. Adults aged 60 and over were interviewed by social, legal, financial, or health services professionals who underwent in-person training on the administration and scoring of the scale. Professionals provided a rating of the decision-making abilities of the older adult. The analytic sample included 213 individuals with an average age of 76.9 (SD = 10.1). The majority (57%) were female. Data were analyzed using item response theory (IRT) methodology. The results supported the unidimensionality of the item set. Several IRT models were tested. Ten ordinal and binary items evidenced a slightly higher reliability estimate (0.85) than other versions and better coverage in terms of the range of reliable measurement across the continuum of financial incapacity.
BDS/GPS Dual Systems Positioning Based on the Modified SR-UKF Algorithm
Kong, JaeHyok; Mao, Xuchu; Li, Shaoyuan
2016-01-01
The Global Navigation Satellite System can provide all-day three-dimensional position and speed information. Currently, only using the single navigation system cannot satisfy the requirements of the system’s reliability and integrity. In order to improve the reliability and stability of the satellite navigation system, the positioning method by BDS and GPS navigation system is presented, the measurement model and the state model are described. Furthermore, the modified square-root Unscented Kalman Filter (SR-UKF) algorithm is employed in BDS and GPS conditions, and analysis of single system/multi-system positioning has been carried out, respectively. The experimental results are compared with the traditional estimation results, which show that the proposed method can perform highly-precise positioning. Especially when the number of satellites is not adequate enough, the proposed method combine BDS and GPS systems to achieve a higher positioning precision. PMID:27153068
The Case for Modular Redundancy in Large-Scale High Performance Computing Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Engelmann, Christian; Ong, Hong Hoe; Scott, Stephen L
2009-01-01
Recent investigations into resilience of large-scale high-performance computing (HPC) systems showed a continuous trend of decreasing reliability and availability. Newly installed systems have a lower mean-time to failure (MTTF) and a higher mean-time to recover (MTTR) than their predecessors. Modular redundancy is being used in many mission critical systems today to provide for resilience, such as for aerospace and command \\& control systems. The primary argument against modular redundancy for resilience in HPC has always been that the capability of a HPC system, and respective return on investment, would be significantly reduced. We argue that modular redundancy can significantly increasemore » compute node availability as it removes the impact of scale from single compute node MTTR. We further argue that single compute nodes can be much less reliable, and therefore less expensive, and still be highly available, if their MTTR/MTTF ratio is maintained.« less
Luján, Manel; Sogo, Ana; Pomares, Xavier; Monsó, Eduard; Sales, Bernat; Blanch, Lluís
2013-05-01
New home ventilators are able to provide clinicians data of interest through built-in software. Monitoring of tidal volume (VT) is a key point in the assessment of the efficacy of home mechanical ventilation. To assess the reliability of the VT provided by 5 ventilators in a bench test. Five commercial ventilators from 4 different manufacturers were tested in pressure support mode with the help of a breathing simulator under different conditions of mechanical respiratory pattern, inflation pressure, and intentional leakage. Values provided by the built-in software of each ventilator were compared breath to breath with the VT monitored through an external pneumotachograph. Ten breaths for each condition were compared for every tested situation. All tested ventilators underestimated VT (ranges of -21.7 mL to -83.5 mL, which corresponded to -3.6% to -14.7% of the externally measured VT). A direct relationship between leak and underestimation was found in 4 ventilators, with higher underestimations of the VT when the leakage increased, ranging between -2.27% and -5.42% for each 10 L/min increase in the leakage. A ventilator that included an algorithm that computes the pressure loss through the tube as a function of the flow exiting the ventilator had the minimal effect of leaks on the estimation of VT (0.3%). In 3 ventilators the underestimation was also influenced by mechanical pattern (lower underestimation with restrictive, and higher with obstructive). The inclusion of algorithms that calculate the pressure loss as a function of the flow exiting the ventilator in commercial models may increase the reliability of VT estimation.
Multiprocessor switch with selective pairing
Gara, Alan; Gschwind, Michael K; Salapura, Valentina
2014-03-11
System, method and computer program product for a multiprocessing system to offer selective pairing of processor cores for increased processing reliability. A selective pairing facility is provided that selectively connects, i.e., pairs, multiple microprocessor or processor cores to provide one highly reliable thread (or thread group). Each paired microprocessor or processor cores that provide one highly reliable thread for high-reliability connect with a system components such as a memory "nest" (or memory hierarchy), an optional system controller, and optional interrupt controller, optional I/O or peripheral devices, etc. The memory nest is attached to a selective pairing facility via a switch or a bus
Individual differences in situation awareness: Validation of the Situationism Scale
Roberts, Megan E.; Gibbons, Frederick X.; Gerrard, Meg; Klein, William M. P.
2015-01-01
This paper concerns the construct of lay situationism—an individual’s belief in the importance of a behavior’s context. Study 1 identified a 13-item Situationism Scale, which demonstrated good reliability and validity. In particular, higher situationism was associated with greater situation-control (strategies to manipulate the environment in order to avoid temptation). Subsequent laboratory studies indicated that people higher on the situationism subscales used greater situation-control by sitting farther from junk food (Study 2) and choosing to drink non-alcoholic beverages before a cognitive task (Study 3). Overall, findings provide preliminary support for the psychometric validity and predictive utility of the Situationism Scale and offer this individual difference construct as a means to expand self-regulation theory. PMID:25329242
Effect of image resolution manipulation in rearfoot angle measurements obtained with photogrammetry
Sacco, I.C.N.; Picon, A.P.; Ribeiro, A.P.; Sartor, C.D.; Camargo-Junior, F.; Macedo, D.O.; Mori, E.T.T.; Monte, F.; Yamate, G.Y.; Neves, J.G.; Kondo, V.E.; Aliberti, S.
2012-01-01
The aim of this study was to investigate the influence of image resolution manipulation on the photogrammetric measurement of the rearfoot static angle. The study design was that of a reliability study. We evaluated 19 healthy young adults (11 females and 8 males). The photographs were taken at 1536 pixels in the greatest dimension, resized into four different resolutions (1200, 768, 600, 384 pixels) and analyzed by three equally trained examiners on a 96-pixels per inch (ppi) screen. An experienced physiotherapist marked the anatomic landmarks of rearfoot static angles on two occasions within a 1-week interval. Three different examiners had marked angles on digital pictures. The systematic error and the smallest detectable difference were calculated from the angle values between the image resolutions and times of evaluation. Different resolutions were compared by analysis of variance. Inter- and intra-examiner reliability was calculated by intra-class correlation coefficients (ICC). The rearfoot static angles obtained by the examiners in each resolution were not different (P > 0.05); however, the higher the image resolution the better the inter-examiner reliability. The intra-examiner reliability (within a 1-week interval) was considered to be unacceptable for all image resolutions (ICC range: 0.08-0.52). The whole body image of an adult with a minimum size of 768 pixels analyzed on a 96-ppi screen can provide very good inter-examiner reliability for photogrammetric measurements of rearfoot static angles (ICC range: 0.85-0.92), although the intra-examiner reliability within each resolution was not acceptable. Therefore, this method is not a proper tool for follow-up evaluations of patients within a therapeutic protocol. PMID:22911379
Effect of image resolution manipulation in rearfoot angle measurements obtained with photogrammetry.
Sacco, I C N; Picon, A P; Ribeiro, A P; Sartor, C D; Camargo-Junior, F; Macedo, D O; Mori, E T T; Monte, F; Yamate, G Y; Neves, J G; Kondo, V E; Aliberti, S
2012-09-01
The aim of this study was to investigate the influence of image resolution manipulation on the photogrammetric measurement of the rearfoot static angle. The study design was that of a reliability study. We evaluated 19 healthy young adults (11 females and 8 males). The photographs were taken at 1536 pixels in the greatest dimension, resized into four different resolutions (1200, 768, 600, 384 pixels) and analyzed by three equally trained examiners on a 96-pixels per inch (ppi) screen. An experienced physiotherapist marked the anatomic landmarks of rearfoot static angles on two occasions within a 1-week interval. Three different examiners had marked angles on digital pictures. The systematic error and the smallest detectable difference were calculated from the angle values between the image resolutions and times of evaluation. Different resolutions were compared by analysis of variance. Inter- and intra-examiner reliability was calculated by intra-class correlation coefficients (ICC). The rearfoot static angles obtained by the examiners in each resolution were not different (P > 0.05); however, the higher the image resolution the better the inter-examiner reliability. The intra-examiner reliability (within a 1-week interval) was considered to be unacceptable for all image resolutions (ICC range: 0.08-0.52). The whole body image of an adult with a minimum size of 768 pixels analyzed on a 96-ppi screen can provide very good inter-examiner reliability for photogrammetric measurements of rearfoot static angles (ICC range: 0.85-0.92), although the intra-examiner reliability within each resolution was not acceptable. Therefore, this method is not a proper tool for follow-up evaluations of patients within a therapeutic protocol.
RELIABILITY AND VALIDITY OF A BIOMECHANICALLY BASED ANALYSIS METHOD FOR THE TENNIS SERVE
Kibler, W. Ben; Lamborn, Leah; Smith, Belinda J.; English, Tony; Jacobs, Cale; Uhl, Tim L.
2017-01-01
Background An observational tennis serve analysis (OTSA) tool was developed using previously established body positions from three-dimensional kinematic motion analysis studies. These positions, defined as nodes, have been associated with efficient force production and minimal joint loading. However, the tool has yet to be examined scientifically. Purpose The primary purpose of this investigation was to determine the inter-observer reliability for each node between two health care professionals (HCPs) that developed the OTSA, and secondarily to investigate the validity of the OTSA. Methods Two separate studies were performed to meet these objectives. An inter-observer reliability study preceded the validity study by examining 28 videos of players serving. Two HCPs graded each video and scored the presence or absence of obtaining each node. Discriminant validity was determined in 33 tennis players using video taped records of three first serves. Serve mechanics were graded using the OSTA and categorized players into those with good ( ≥ 5) and poor ( ≤ 4) mechanics. Participants performed a series of field tests to evaluate trunk flexibility, lower extremity and trunk power, and dynamic balance. Results The group with good mechanics demonstrated greater backward trunk flexibility (p=0.02), greater rotational power (p=0.02), and higher single leg countermovement jump (p=0.05). Reliability of the OTSA ranged from K = 0.36-1.0, with the majority of all the nodes displaying substantial reliability (K>0.61). Conclusion This study provides HCPs with a valid and reliable field tool used to assess serve mechanics. Physical characteristics of trunk mobility and power appear to discriminate serve mechanics between players. Future intervention studies are needed to determine if improvement in physical function contribute to improved serve mechanics. Level of Evidence 3 PMID:28593098
Duncan, Laura; Comeau, Jinette; Wang, Li; Vitoroulis, Irene; Boyle, Michael H; Bennett, Kathryn
2018-02-19
A better understanding of factors contributing to the observed variability in estimates of test-retest reliability in published studies on standardized diagnostic interviews (SDI) is needed. The objectives of this systematic review and meta-analysis were to estimate the pooled test-retest reliability for parent and youth assessments of seven common disorders, and to examine sources of between-study heterogeneity in reliability. Following a systematic review of the literature, multilevel random effects meta-analyses were used to analyse 202 reliability estimates (Cohen's kappa = ҡ) from 31 eligible studies and 5,369 assessments of 3,344 children and youth. Pooled reliability was moderate at ҡ = .58 (CI 95% 0.53-0.63) and between-study heterogeneity was substantial (Q = 2,063 (df = 201), p < .001 and I 2 = 79%). In subgroup analysis, reliability varied across informants for specific types of psychiatric disorder (ҡ = .53-.69 for parent vs. ҡ = .39-.68 for youth) with estimates significantly higher for parents on attention deficit hyperactivity disorder, oppositional defiant disorder and the broad groupings of externalizing and any disorder. Reliability was also significantly higher in studies with indicators of poor or fair study methodology quality (sample size <50, retest interval <7 days). Our findings raise important questions about the meaningfulness of published evidence on the test-retest reliability of SDIs and the usefulness of these tools in both clinical and research contexts. Potential remedies include the introduction of standardized study and reporting requirements for reliability studies, and exploration of other approaches to assessing and classifying child and adolescent psychiatric disorder. © 2018 Association for Child and Adolescent Mental Health.
NASA Technical Reports Server (NTRS)
Bavuso, Salvatore J.; Rothmann, Elizabeth; Dugan, Joanne Bechta; Trivedi, Kishor S.; Mittal, Nitin; Boyd, Mark A.; Geist, Robert M.; Smotherman, Mark D.
1994-01-01
The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed to be compatible with most computing platforms and operating systems, and some programs have been beta tested, within the aerospace community for over 8 years. Volume 1 provides an introduction to the HARP program. Comprehensive information on HARP mathematical models can be found in the references.
Methodology for Physics and Engineering of Reliable Products
NASA Technical Reports Server (NTRS)
Cornford, Steven L.; Gibbel, Mark
1996-01-01
Physics of failure approaches have gained wide spread acceptance within the electronic reliability community. These methodologies involve identifying root cause failure mechanisms, developing associated models, and utilizing these models to inprove time to market, lower development and build costs and higher reliability. The methodology outlined herein sets forth a process, based on integration of both physics and engineering principles, for achieving the same goals.
Reliability of TMS metrics in patients with chronic incomplete spinal cord injury.
Potter-Baker, K A; Janini, D P; Frost, F S; Chabra, P; Varnerin, N; Cunningham, D A; Sankarasubramanian, V; Plow, E B
2016-11-01
Test-retest reliability analysis in individuals with chronic incomplete spinal cord injury (iSCI). The purpose of this study was to examine the reliability of neurophysiological metrics acquired with transcranial magnetic stimulation (TMS) in individuals with chronic incomplete tetraplegia. Cleveland Clinic Foundation, Cleveland, Ohio, USA. TMS metrics of corticospinal excitability, output, inhibition and motor map distribution were collected in muscles with a higher MRC grade and muscles with a lower MRC grade on the more affected side of the body. Metrics denoting upper limb function were also collected. All metrics were collected at two sessions separated by a minimum of two weeks. Reliability between sessions was determined using Spearman's correlation coefficients and concordance correlation coefficients (CCCs). We found that TMS metrics that were acquired in higher MRC grade muscles were approximately two times more reliable than those collected in lower MRC grade muscles. TMS metrics of motor map output, however, demonstrated poor reliability regardless of muscle choice (P=0.34; CCC=0.51). Correlation analysis indicated that patients with more baseline impairment and/or those in a more chronic phase of iSCI demonstrated greater variability of metrics. In iSCI, reliability of TMS metrics varies depending on the muscle grade of the tested muscle. Variability is also influenced by factors such as baseline motor function and time post SCI. Future studies that use TMS metrics in longitudinal study designs to understand functional recovery should be cautious as choice of muscle and clinical characteristics can influence reliability.
NASA Astrophysics Data System (ADS)
Dolzhenkova, E. V.; Iurieva, L. V.
2018-05-01
The study presents the author's algorithm for the industrial enterprise repair service organization simulation based on the reliability theory, as well as the results of its application. The monitoring of the industrial enterprise repair service organization is proposed to perform on the basis of the enterprise's state indexes for the main resources (equipment, labour, finances, repair areas), which allows quantitative evaluation of the reliability level as a resulting summary rating of the said parameters and the ensuring of an appropriate level of the operation reliability of the serviced technical objects. Under the conditions of the tough competition, the following approach is advisable: the higher efficiency of production and a repair service itself, the higher the innovative attractiveness of an industrial enterprise. The results of the calculations show that in order to prevent inefficient losses of production and to reduce the repair costs, it is advisable to apply the reliability theory. The overall reliability rating calculated on the basis of the author's algorithm has low values. The processing of the statistical data forms the reliability characteristics for the different workshops and services of an industrial enterprise, which allows one to define the failure rates of the various units of equipment and to establish the reliability indexes necessary for the subsequent mathematical simulation. The proposed simulating algorithm contributes to an increase of the efficiency of the repair service organization and improvement of the innovative attraction of an industrial enterprise.
Space Transportation System Availability Requirement and Its Influencing Attributes Relationships
NASA Technical Reports Server (NTRS)
Rhodes, Russell E.; Adams, Timothy C.; McCleskey, Carey M.
2008-01-01
It is important that engineering and management accept the need for an availability requirement that is derived with its influencing attributes. It is the intent of this paper to provide the visibility of relationships of these major attribute drivers (variables) to each other and the resultant system inherent availability. Also important to provide bounds of the variables providing engineering the insight required to control the system's engineering solution, e.g., these influencing attributes become design requirements also. These variables will drive the need to provide integration of similar discipline functions or technology selection to allow control of the total parts count. The relationship of selecting a reliability requirement will place a constraint on parts count to achieve a given availability requirement or if allowed to increase the parts count will drive the system reliability requirement higher. They also provide the understanding for the relationship of mean repair time (or mean down time) to maintainability, e.g., accessibility for repair, and both the mean time between failure, e.g., reliability of hardware and availability. The concerns and importance of achieving a strong availability requirement is driven by the need for affordability, the choice of using the two launch solution for the single space application, or the need to control the spare parts count needed to support the long stay in either orbit or on the surface of the moon. Understanding the requirements before starting the architectural design concept will avoid considerable time and money required to iterate the design to meet the redesign and assessment process required to achieve the results required of the customer's space transportation system. In fact the impact to the schedule to being able to deliver the system that meets the customer's needs, goals, and objectives may cause the customer to compromise his desired operational goal and objectives resulting in considerable increased life cycle cost of the fielded space transportation system.
Space Transportation System Availability Requirements and Its Influencing Attributes Relationships
NASA Technical Reports Server (NTRS)
Rhodes, Russell E.; Adams, Timothy C.; McCleskey, Carey M.
2008-01-01
It is important that engineering and management accept the need for an availability requirement that is derived with its influencing attributes. It is the intent of this paper to provide the visibility of relationships of these major attribute drivers (variables) to each other and the resultant system inherent availability. Also important to provide bounds of the variables providing engineering the insight required to control the system's engineering solution, e.g., these influencing attributes become design requirements also. These variables will drive the need to provide integration of similar discipline functions or technology selection to allow control of the total parts count. The relationship of selecting a reliability requirement will place a constraint on parts count to achieve a given availability requirement or if allowed to increase the parts count will drive the system reliability requirement higher. They also provide the understanding for the relationship of mean repair time (or mean down time) to maintainability, e.g., accessibility for repair, and both the mean time between failure, e.g., reliability of hardware and availability. The concerns and importance of achieving a strong availability requirement is driven by the need for affordability, the choice of using the two launch solution for the single space application, or the need to control the spare parts count needed to support the long stay in either orbit or on the surface of the moon. Understanding the requirements before starting the architectural design concept will avoid considerable time and money required to iterate the design to meet the redesign and assessment process required to achieve the results required of the customer's space transportation system. In fact the impact to the schedule to being able to deliver the system that meets the customer's needs, goals, and objectives may cause the customer to compromise his desired operational goal and objectives resulting in considerable increased life cycle cost of the fielded space transportation system.
Nelson, Eve-Lynn; Miller, Edward Alan; Larson, Kiley A
2010-01-01
This study's purpose was to adapt the Roter Interaction Analysis System (RIAS) for telemedicine clinics and to investigate the adapted measure's reliability. The study also sought to better understand the volume of technology-related utterance in established telemedicine clinics and the feasibility of using the measure within the telemedicine setting. This initial evaluation is a first step before broadly using the adapted measure across technologies and raters. An expert panel adapted the RIAS for the telemedicine context. This involved accounting for all consultation participants (patient, provider, presenter, family) and adding technology-specific subcategories. Ten new and 36 follow-up telemedicine encounters were videotaped and double coded using the adapted RIAS. These consisted primarily of follow-up visits (78.0%) involving patients, providers, presenters, and other parties. Reliability was calculated for those categories with 15 or more utterances. Traditional RIAS categories related to socioemotional and task-focused clusters had fair to excellent levels of reliability in the telemedicine setting. Although there were too few utterances to calculate the reliability of the specific technology-related subcategories, the summary technology-related category proved reliable for patients, providers, and presenters. Overall patterns seen in traditional patient-provider interactions were observed, with the number of provider utterances far exceeding patient, presenter, and family utterances, and few technology-specific utterances. The traditional RIAS is reliable when applied across multiple participants in the telemedicine context. Reliability of technology-related subcategories could not be evaluated; however, the aggregate technology-related cluster was found to be reliable and may be especially relevant in understanding communication patterns with patients new to the telemedicine setting. Use of the RIAS instrument is encouraged to facilitate comparison between traditional, face-to-face clinics and telemedicine; among diverse consultation mediums and technologies; and across different specialties. Future research is necessary to further investigate the reliability and validity of adding technology-related subcategories to the RIAS. The limited number of technology-related utterances, however, implies a certain degree of comfort with two-way interactive video consultation among study participants. Telemedicine continues to increase access to healthcare. The technology-related categories of the adapted RIAS were reliable when aggregated, thereby providing a tool to better understand how telemedicine affects provider-patient communication and outcomes.
Research productivity and gender disparities: a look at academic plastic surgery.
Paik, Angie M; Mady, Leila J; Villanueva, Nathaniel L; Goljo, Erden; Svider, Peter F; Ciminello, Frank; Eloy, Jean Anderson
2014-01-01
The h-index has utility in examining the contributions of faculty members by quantifying both the amount and the quality of research output and as such is a metric in approximating academic productivity. The objectives of this study were (1) to evaluate the relationship between h-index and academic rank in plastic surgery and (2) to describe the current gender representation in academic plastic surgery to assess whether there are any gender disparities in academic productivity. The h-index was used to evaluate the research contributions of plastic surgeons from academic departments in the United States. There were 426 (84%) men and 79 (16%) women in our sample. Those in higher academic ranks had higher h-index scores (p < 0.0005). There was a significant difference in overall mean h-index by gender, where the mean scores were 9.0 and 6.0 for men and women, respectively (p = 0.0005). When analyzed by academic rank, there was a significant difference in academic productivity between men and women in assistant and associate professor positions (6.4 vs 5.1, respectively; p = 0.04). The h-index is able to objectively and reliably quantify academic productivity in plastic surgery. We found that h-indices increased with higher academic rank, and men had overall higher scores than their female colleagues. Adoption of this metric as an adjunct to other objective and subjective measures by promotions committees may provide a more reliable measure of research relevance and academic productivity in academic plastic surgery. Copyright © 2014 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Kim, Dohyun; Ahn, So-Yeon; Kim, Junyoung; Park, Sung-Ho
2017-07-01
Since 2007, the FDI World Dental Federation (FDI) criteria have been used for the clinical evaluation of dental restorations. However, the reliability of the FDI criteria has not been sufficiently addressed. The purpose of this study was to assess and compare the interrater and intrarater reliability of the FDI criteria by evaluating posterior tooth-colored restorations photographically. A total of 160 clinical photographs of posterior tooth-colored restorations were evaluated independently by 5 raters with 9 of the FDI criteria suitable for photographic evaluation. The raters recorded the score of each restoration by using 5 grades, and the score was dichotomized into the clinical evaluation scores. After 1 month, 2 of the raters reevaluated the same set of 160 photographs in random order. To estimate the interrater reliability among the 5 raters, the proportion of agreement was calculated, and the Fleiss multirater kappa statistic was used. For the intrarater reliability, the proportion of agreement was calculated, and the Cohen standard kappa statistic was used for each of the 2 raters. The interrater proportion of agreement was 0.41 to 0.57, and the kappa value was 0.09 to 0.39. Overall, the intrarater reliability was higher than the interrater reliability, and rater 1 demonstrated higher intrarater reliability than rater 2. The proportion of agreement and kappa values increased when the 5 scores were dichotomized. The reliability was relatively lower for the esthetic properties compared with the functional or biological properties. Within the limitations of this study, the FDI criteria presented slight to fair interrater reliability and fair to excellent intrarater reliability in the photographic evaluation of posterior tooth-colored restorations. The reliability was improved by simplifying the evaluation scores. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Automated software development workstation
NASA Technical Reports Server (NTRS)
Prouty, Dale A.; Klahr, Philip
1988-01-01
A workstation is being developed that provides a computational environment for all NASA engineers across application boundaries, which automates reuse of existing NASA software and designs, and efficiently and effectively allows new programs and/or designs to be developed, catalogued, and reused. The generic workstation is made domain specific by specialization of the user interface, capturing engineering design expertise for the domain, and by constructing/using a library of pertinent information. The incorporation of software reusability principles and expert system technology into this workstation provide the obvious benefits of increased productivity, improved software use and design reliability, and enhanced engineering quality by bringing engineering to higher levels of abstraction based on a well tested and classified library.
Differential Privacy Preserving in Big Data Analytics for Connected Health.
Lin, Chi; Song, Zihao; Song, Houbing; Zhou, Yanhong; Wang, Yi; Wu, Guowei
2016-04-01
In Body Area Networks (BANs), big data collected by wearable sensors usually contain sensitive information, which is compulsory to be appropriately protected. Previous methods neglected privacy protection issue, leading to privacy exposure. In this paper, a differential privacy protection scheme for big data in body sensor network is developed. Compared with previous methods, this scheme will provide privacy protection with higher availability and reliability. We introduce the concept of dynamic noise thresholds, which makes our scheme more suitable to process big data. Experimental results demonstrate that, even when the attacker has full background knowledge, the proposed scheme can still provide enough interference to big sensitive data so as to preserve the privacy.
Comparison of de novo assembly statistics of Cucumis sativus L.
NASA Astrophysics Data System (ADS)
Wojcieszek, Michał; Kuśmirek, Wiktor; Pawełkowicz, Magdalena; PlÄ der, Wojciech; Nowak, Robert M.
2017-08-01
Genome sequencing is the core of genomic research. With the development of NGS and lowering the cost of procedure there is another tight gap - genome assembly. Developing the proper tool for this task is essential as quality of genome has important impact on further research. Here we present comparison of several de Bruijn assemblers tested on C. sativus genomic reads. The assessment shows that newly developed software - dnaasm provides better results in terms of quantity and quality. The number of generated sequences is lower by 5 - 33% with even two fold higher N50. Quality check showed reliable results were generated by dnaasm. This provides us with very strong base for future genomic analysis.
Impute DC link (IDCL) cell based power converters and control thereof
Divan, Deepakraj M.; Prasai, Anish; Hernendez, Jorge; Moghe, Rohit; Iyer, Amrit; Kandula, Rajendra Prasad
2016-04-26
Power flow controllers based on Imputed DC Link (IDCL) cells are provided. The IDCL cell is a self-contained power electronic building block (PEBB). The IDCL cell may be stacked in series and parallel to achieve power flow control at higher voltage and current levels. Each IDCL cell may comprise a gate drive, a voltage sharing module, and a thermal management component in order to facilitate easy integration of the cell into a variety of applications. By providing direct AC conversion, the IDCL cell based AC/AC converters reduce device count, eliminate the use of electrolytic capacitors that have life and reliability issues, and improve system efficiency compared with similarly rated back-to-back inverter system.
Design of reliable universal QCA logic in the presence of cell deposition defect
NASA Astrophysics Data System (ADS)
Sen, Bibhash; Mukherjee, Rijoy; Mohit, Kumar; Sikdar, Biplab K.
2017-08-01
The emergence of Quantum-dot Cellular Automata (QCA) has resulted in being identified as a promising alternative to the currently prevailing techniques of very large scale integration. QCA can provide low-power nanocircuit with high device density. Keeping aside the profound acceptance of QCA, the challenge that it is facing can be quoted as susceptibility to high error rate. The work produced in this article aims towards the design of a reliable universal logic gate (r-ULG) in QCA (r-ULG along with the single clock zone and r-ULG-II along with multiple clock zones). The design would include hybrid orientation of cells that would realise majority and minority, functions and high fault tolerance simultaneously. The characterisation of the defective behaviour of r-ULGs under different kinds of cell deposition defects is investigated. The outcomes of the investigation provide an indication that the proposed r-ULG provides a fault tolerance of 75% under single clock zone and a fault tolerance of 100% under dual clock zones. The high functional aspects of r-ULGs in the implementation of different logic functions successfully under cell deposition defects are affirmed by the experimental results. The high-level logic around the multiplexer is synthesised, which helps to extend the design capability to the higher-level circuit synthesis.
Interrater reliability of early intervention providers scoring the alberta infant motor scale.
Blanchard, Y; Neilan, E; Busanich, J; Garavuso, L; Klimas, D
2004-01-01
This study was designed to examine the interrater reliability of early intervention providers scoring of the Alberta Infant Motor Scale (AIMS) and to examine whether training on the AIMS would improve their interrater reliability. Eight early intervention providers were randomly assigned to two groups. Participants in Group 1 scored the AIMS on seven videotapes of infants prior to receiving training and after training on another set of seven videotapes of infants. Participants in Group 2 scored the AIMS on all 14 videotapes of the infants after receiving training. Overall interrater reliability before and after training was high with intraclass correlation coefficients ranging from 0.98 to 0.99. Detailed examination of the results showed that training improved the reliability of the supine subscale in a subgroup of infants between the ages of five and seven months. Training also had an effect on the classification of infants as normal or abnormal in their motor development based on their percentile rankings. The AIMS manual provides sufficient information to attain high interrater reliability without training, but revisions regarding scoring are strongly recommended.
The accuracy of ultrasound for measurement of mobile- bearing motion.
Aigner, Christian; Radl, Roman; Pechmann, Michael; Rehak, Peter; Stacher, Rudolf; Windhager, Reinhard
2004-04-01
After anterior cruciate ligament-sacrificing total knee replacement, mobile bearings sometimes have paradoxic movement but the implications of such movement on function, wear, and implant survival are not known. To study this potential problem accurate, reliable, and widely available inexpensive tools for in vivo mobile-bearing motion analyses are needed. We developed a method using an 8-MHz ultrasound to analyze mobile-bearing motion and ascertained accuracy, precision, and reliability compared with plain and standard digital radiographs. The anterior rim of the mobile bearing was the target for all methods. The radiographs were taken in a horizontal plane at neutral rotation and incremental external and internal rotations. Five investigators examined four positions of the mobile bearing with all three methods. The accuracy and precision were: ultrasound, 0.7 mm and 0.2 mm; digital radiograph, 0.4 mm and 0.2 mm; and plain radiographs, 0.7 mm and 0.3 mm. The interrater and intrarater reliability ranged between 0.3 to 0.4 mm and 0.1 to 0.2 mm, respectively. The difference between the methods was not significant for neutral rotation but ultrasound was significantly more accurate than any one degree of rotation or higher. Ultrasound of 8 MHz provides an accuracy and reliability that is suitable for evaluation of in vivo meniscal bearing motion. Whether this method or others are sufficiently accurate to detect motion leading to abnormal wear is not known.
An N-targeting real-time PCR strategy for the accurate detection of spring viremia of carp virus.
Shao, Ling; Xiao, Yu; He, Zhengkan; Gao, Longying
2016-03-01
Spring viremia of carp virus (SVCV) is a highly pathogenic agent of several economically important Cyprinidae fish species. Currently, there are no effective vaccines or drugs for this virus, and prevention of the disease mostly relies on prompt diagnosis. Previously, nested RT-PCR and RT-qPCR detection methods based on the glycoprotein gene G have been developed. However, the high genetic diversity of the G gene seriously limits the reliability of those methods. Compared with the G gene, phylogenetic analyses indicate that the nucleoprotein gene N is more conserved. Furthermore, studies in other members of the Rhabdoviridae family reveals that their gene transcription level follows the order N>P>M>G>L, indicating that an N gene based RT-PCR should have higher sensitivity. Therefore, two pairs of primers and two corresponding probes targeting the conserved regions of the N gene were designed. RT-qPCR assays demonstrated all primers and probes could detect phylogenetically distant isolates specifically and efficiently. Moreover, in artificially infected fish, the detected copy numbers of the N gene were much higher than those of the G gene in all tissues, and both the N and G gene copy numbers were highest in the kidney and spleen. Testing in 1100 farm-raised fish also showed that the N-targeting strategy was more reliable than the G-targeting methods. The method developed in this study provides a reliable tool for the rapid diagnosis of SVCV. Copyright © 2015 Elsevier B.V. All rights reserved.
Ferguson, Kristi J; Kreiter, Clarence D; Haugen, Thomas H; Dee, Fred R
2018-02-20
As medical schools move from discipline-based courses to more integrated approaches, identifying assessment tools that parallel this change is an important goal. The authors describe the use of test item statistics to assess the reliability and validity of web-enabled mechanistic case diagrams (MCDs) as a potential tool to assess students' ability to integrate basic science and clinical information. Students review a narrative clinical case and construct an MCD using items provided by the case author. Students identify the relationships among underlying risk factors, etiology, pathogenesis and pathophysiology, and the patients' signs and symptoms. They receive one point for each correctly-identified link. In 2014-15 and 2015-16, case diagrams were implemented in consecutive classes of 150 medical students. The alpha reliability coefficient for the overall score, constructed using each student's mean proportion correct across all cases, was 0.82. Discrimination indices for each of the case scores with the overall score ranged from 0.23 to 0.51. In a G study using those students with complete data (n = 251) on all 16 cases, 10% of the variance was true score variance, and systematic case variance was large. Using 16 cases generated a G coefficient (relative score reliability) equal to .72 and a Phi equal to .65. The next phase of the project will involve deploying MCDs in higher-stakes settings to determine whether similar results can be achieved. Further analyses will determine whether these assessments correlate with other measures of higher-order thinking skills.
Ebeling, Daniel; Solares, Santiago D
2013-01-01
We present an overview of the bimodal amplitude-frequency-modulation (AM-FM) imaging mode of atomic force microscopy (AFM), whereby the fundamental eigenmode is driven by using the amplitude-modulation technique (AM-AFM) while a higher eigenmode is driven by using either the constant-excitation or the constant-amplitude variant of the frequency-modulation (FM-AFM) technique. We also offer a comparison to the original bimodal AFM method, in which the higher eigenmode is driven with constant frequency and constant excitation amplitude. General as well as particular characteristics of the different driving schemes are highlighted from theoretical and experimental points of view, revealing the advantages and disadvantages of each. This study provides information and guidelines that can be useful in selecting the most appropriate operation mode to characterize different samples in the most efficient and reliable way.
NASA Technical Reports Server (NTRS)
Hou, Gene J.-W; Newman, Perry A. (Technical Monitor)
2004-01-01
A major step in a most probable point (MPP)-based method for reliability analysis is to determine the MPP. This is usually accomplished by using an optimization search algorithm. The minimum distance associated with the MPP provides a measurement of safety probability, which can be obtained by approximate probability integration methods such as FORM or SORM. The reliability sensitivity equations are derived first in this paper, based on the derivatives of the optimal solution. Examples are provided later to demonstrate the use of these derivatives for better reliability analysis and reliability-based design optimization (RBDO).
Autonomic Computing for Spacecraft Ground Systems
NASA Technical Reports Server (NTRS)
Li, Zhenping; Savkli, Cetin; Jones, Lori
2007-01-01
Autonomic computing for spacecraft ground systems increases the system reliability and reduces the cost of spacecraft operations and software maintenance. In this paper, we present an autonomic computing solution for spacecraft ground systems at NASA Goddard Space Flight Center (GSFC), which consists of an open standard for a message oriented architecture referred to as the GMSEC architecture (Goddard Mission Services Evolution Center), and an autonomic computing tool, the Criteria Action Table (CAT). This solution has been used in many upgraded ground systems for NASA 's missions, and provides a framework for developing solutions with higher autonomic maturity.
3D MEMS in Standard Processes: Fabrication, Quality Assurance, and Novel Measurement Microstructures
NASA Technical Reports Server (NTRS)
Lin, Gisela; Lawton, Russell A.
2000-01-01
Three-dimensional MEMS microsystems that are commercially fabricated require minimal post-processing and are easily integrated with CMOS signal processing electronics. Measurements to evaluate the fabrication process (such as cross-sectional imaging and device performance characterization) provide much needed feedback in terms of reliability and quality assurance. MEMS technology is bringing a new class of microscale measurements to fruition. The relatively small size of MEMS microsystems offers the potential for higher fidelity recordings compared to macrosize counterparts, as illustrated in the measurement of muscle cell forces.
Balaguier, Romain; Madeleine, Pascal; Vuillerme, Nicolas
2016-01-01
The assessment of pressure pain threshold (PPT) provides a quantitative value related to the mechanical sensitivity to pain of deep structures. Although excellent reliability of PPT has been reported in numerous anatomical locations, its absolute and relative reliability in the lower back region remains to be determined. Because of the high prevalence of low back pain in the general population and because low back pain is one of the leading causes of disability in industrialized countries, assessing pressure pain thresholds over the low back is particularly of interest. The purpose of this study study was (1) to evaluate the intra- and inter- absolute and relative reliability of PPT within 14 locations covering the low back region of asymptomatic individuals and (2) to determine the number of trial required to ensure reliable PPT measurements. Fifteen asymptomatic subjects were included in this study. PPTs were assessed among 14 anatomical locations in the low back region over two sessions separated by one hour interval. For the two sessions, three PPT assessments were performed on each location. Reliability was assessed computing intraclass correlation coefficients (ICC), standard error of measurement (SEM) and minimum detectable change (MDC) for all possible combinations between trials and sessions. Bland-Altman plots were also generated to assess potential bias in the dataset. Relative reliability for both intra- and inter- session was almost perfect with ICC ranged from 0.85 to 0.99. With respect to the intra-session, no statistical difference was reported for ICCs and SEM regardless of the conducted comparisons between trials. Conversely, for inter-session, ICCs and SEM values were significantly larger when two consecutive PPT measurements were used for data analysis. No significant difference was observed for the comparison between two consecutive measurements and three measurements. Excellent relative and absolute reliabilities were reported for both intra- and inter-session. Reliable measurements can be equally achieved when using the mean of two or three consecutive PPT measurements, as usually proposed in the literature, or with only the first one. Although reliability was almost perfect regardless of the conducted comparison between PPT assessments, our results suggest using two consecutive measurements to obtain higher short term absolute reliability.
18 CFR 39.3 - Electric Reliability Organization certification.
Code of Federal Regulations, 2010 CFR
2010-04-01
... operators of the Bulk-Power System, and other interested parties for improvement of the Electric Reliability... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Electric Reliability..., Reliability Standards that provide for an adequate level of reliability of the Bulk-Power System, and (2) Has...
Preliminary Development of a Multidimensional Semantic Patient Experience Measurement Questionnaire.
Kleiss, James A
2016-10-01
The purpose of this research was to assess the utility and reliability of a multidimensional patient experience measurement questionnaire in a clinical setting. Patient experience has emerged as an important metric for quality of healthcare. A number of separate concepts have been used to measure patient experience, but psychological research suggests that subjective experience is actually a composite of several independent concepts including: (a) evaluation/valence, (b) potency/control, (c) activity/arousal, and (d) novelty. The present research evaluates the reliability of a multidimensional patient experience measurement questionnaire in a clinical setting. A multidimensional semantic differential questionnaire was developed to measure the four underlying semantic dimensions of patient experience mentioned above. A group of 60 patients used the questionnaire to assess prescan expectations and postscan experience of a magnetic resonance scan. Data for one patient were deleted because their scan was interrupted. Results revealed more positive evaluation/valence, higher potency/control, and lower activity/arousal for postscan ratings compared to prescan expectations. Ratings of novelty were neutral in both the prescan and the postscan conditions. Subsequent analysis suggested that internal consistency for some concepts could be improved by replacing several specific rating scales. Present results provide evidence of the utility and reliability of a multidimensional semantic questionnaire for measuring patient experience in an actual clinical setting. Recommendations to improve internal consistency for the concepts potency/control, activity/arousal, and novelty were also provided. © The Author(s) 2016.
Kelly, Natasha B.; Alonzo, Suzanne H.
2009-01-01
Existing theory predicts that male signalling can be an unreliable indicator of paternal care, but assumes that males with high levels of mating success can have high current reproductive success, without providing any parental care. As a result, this theory does not hold for the many species where offspring survival depends on male parental care. We modelled male allocation of resources between advertisement and care for species with male care where males vary in quality, and the effect of care and advertisement on male fitness is multiplicative rather than additive. Our model predicts that males will allocate proportionally more of their resources to whichever trait (advertisement or paternal care) is more fitness limiting. In contrast to previous theory, we find that male advertisement is always a reliable indicator of paternal care and male phenotypic quality (e.g. males with higher levels of advertisement never allocate less to care than males with lower levels of advertisement). Our model shows that the predicted pattern of male allocation and the reliability of male signalling depend very strongly on whether paternal care is assumed to be necessary for offspring survival and how male care affects offspring survival and male fitness. PMID:19520802
NASA Technical Reports Server (NTRS)
Martin, Ken E.; Esztergalyos, J.
1992-01-01
The Bonneville Power Administration (BPA) uses IRIG-B transmitted over microwave as its primary system time dissemination. Problems with accuracy and reliability have led to ongoing research into better methods. BPA has also developed and deployed a unique fault locator which uses precise clocks synchronized by a pulse over microwaves. It automatically transmits the data to a central computer for analysis. A proposed system could combine fault location timing and time dissemination into a Global Position System (GPS) timing receiver and close the verification loop through a master station at the Dittmer Control Center. Such a system would have many advantages, including lower cost, higher reliability, and wider industry support. Test results indicate the GPS has sufficient accuracy and reliability for this and other current timing requirements including synchronous phase angle measurements. A phasor measurement system which provides phase angle has recently been tested with excellent results. Phase angle is a key parameter in power system control applications including dynamic braking, DC modulation, remedial action schemes, and system state estimation. Further research is required to determine the applications which can most effectively use real-time phase angle measurements and the best method to apply them.
NASA Astrophysics Data System (ADS)
Martin, Ken E.; Esztergalyos, J.
1992-07-01
The Bonneville Power Administration (BPA) uses IRIG-B transmitted over microwave as its primary system time dissemination. Problems with accuracy and reliability have led to ongoing research into better methods. BPA has also developed and deployed a unique fault locator which uses precise clocks synchronized by a pulse over microwaves. It automatically transmits the data to a central computer for analysis. A proposed system could combine fault location timing and time dissemination into a Global Position System (GPS) timing receiver and close the verification loop through a master station at the Dittmer Control Center. Such a system would have many advantages, including lower cost, higher reliability, and wider industry support. Test results indicate the GPS has sufficient accuracy and reliability for this and other current timing requirements including synchronous phase angle measurements. A phasor measurement system which provides phase angle has recently been tested with excellent results. Phase angle is a key parameter in power system control applications including dynamic braking, DC modulation, remedial action schemes, and system state estimation. Further research is required to determine the applications which can most effectively use real-time phase angle measurements and the best method to apply them.
Kelly, Natasha B; Alonzo, Suzanne H
2009-09-07
Existing theory predicts that male signalling can be an unreliable indicator of paternal care, but assumes that males with high levels of mating success can have high current reproductive success, without providing any parental care. As a result, this theory does not hold for the many species where offspring survival depends on male parental care. We modelled male allocation of resources between advertisement and care for species with male care where males vary in quality, and the effect of care and advertisement on male fitness is multiplicative rather than additive. Our model predicts that males will allocate proportionally more of their resources to whichever trait (advertisement or paternal care) is more fitness limiting. In contrast to previous theory, we find that male advertisement is always a reliable indicator of paternal care and male phenotypic quality (e.g. males with higher levels of advertisement never allocate less to care than males with lower levels of advertisement). Our model shows that the predicted pattern of male allocation and the reliability of male signalling depend very strongly on whether paternal care is assumed to be necessary for offspring survival and how male care affects offspring survival and male fitness.
Weech-Maldonado, Robert; Dreachslin, Janice L.; Brown, Julie; Pradhan, Rohit; Rubin, Kelly L.; Schiller, Cameron; Hays, Ron D.
2016-01-01
Background The U.S. national standards for culturally and linguistically appropriate services (CLAS) in health care provide guidelines on policies and practices aimed at developing culturally competent systems of care. The Cultural Competency Assessment Tool for Hospitals (CCATH) was developed as an organizational tool to assess adherence to the CLAS standards. Purposes First, we describe the development of the CCATH and estimate the reliability and validity of the CCATH measures. Second, we discuss the managerial implications of the CCATH as an organizational tool to assess cultural competency. Methodology/Approach We pilot tested an initial draft of the CCATH, revised it based on a focus group and cognitive interviews, and then administered it in a field test with a sample of California hospitals. The reliability and validity of the CCATH were evaluated using factor analysis, analysis of variance, and Cronbach’s alphas. Findings Exploratory and confirmatory factor analyses identified 12 CCATH composites: leadership and strategic planning, data collection on inpatient population, data collection on service area, performance management systems and quality improvement, human resources practices, diversity training, community representation, availability of interpreter services, interpreter services policies, quality of interpreter services, translation of written materials, and clinical cultural competency practices. All the CCATH scales had internal consistency reliability of .65 or above, and the reliability was .70 or above for 9 of the 12 scales. Analysis of variance results showed that not-for-profit hospitals have higher CCATH scores than for-profit hospitals in five CCATH scales and higher CCATH scores than government hospitals in two CCATH scales. Practice Implications The CCATH showed adequate psychometric properties. Managers and policy makers can use the CCATH as a tool to evaluate hospital performance in cultural competency and identify and target improvements in hospital policies and practices that undergird the provision of CLAS. PMID:21934511
Tews, Matthew C; Treat, Robert W; Nanes, Maxwell
2016-07-01
Medical students on an emergency medicine rotation are traditionally evaluated at the end of each shift with paper-based forms, and data are often missing due to forms not being turned in or completed. Because students' grades depend on these evaluations, change was needed to increase form rate of return. We analyzed a new electronic evaluation form and modified completion process to determine if it would increase the completion rate without altering how faculty scored student performance. During fall 2013, 29 faculty completed paper N=339 evaluations consisting of seven competencies for 33 students. In fall 2014, an electronic evaluation form with the same competencies was designed using an electronic platform and completed N=319 times by 27 faculty using 25 students' electronic devices. Feedback checkboxes were added to facilitate collection of common comments. Data was analyzed with IBM® SPSS® 21.0 using multi-factor analysis of variance with the students' global rating (GR) as an outcome. Inter-item reliability was determined with Cronbach alpha. There was a significantly higher completion rate (p=0.001) of 98% electronic vs. 69% paper forms, lower (p=0.001) missed GR rate (1% electronic. vs 12% paper), and higher mean scores (p=0.001) for the GR with the electronic (7.0±1.1) vs. paper (6.8±1.2) form. Feedback checkboxes were completed on every form. The inter-item reliability for electronic and paper forms was each alpha=0.95. The use of a new electronic form and modified completion process for evaluating students at the end of shift demonstrated a higher faculty completion rate, a lower missed data rate, a higher global rating and consistent collection of common feedback. The use of the electronic form and the process for obtaining the information made our end-of-shift evaluation process for students more reliable and provided more accurate, up-to-date information for student feedback and when determining student grades.
Chen, Ruoqing; Hao, Yuantao; Feng, Lifen; Zhang, Yingfen; Huang, Zhuoyan
2011-03-23
A pediatric chronic health condition not only influences a child's life, but also has impacts on parent health-related quality of life (HRQOL) and family functioning. To provide care and social support to these families, a psychometrically well-developed instrument for measuring these impacts is of great importance. The present study is aimed to evaluate the psychometric properties of the Chinese version of the PedsQL™ Family Impact Module. The cross-cultural adaptation of the PedsQL™ Family Impact Module was performed following the PedsQL™ Measurement Model Translation Methodology. The Chinese version of the PedsQL™ Family Impact Module was administered to 136 parents of children with asthma and 264 parents of children with heart disease from four Triple A hospitals. The psychometric properties such as feasibility, internal consistency reliability, item-subscale correlations and construct validity were evaluated. The percentage of missing item responses was less than 0.1% for both asthma and heart disease sample groups. The Chinese version of the PedsQL™ Family Impact Module showed ceiling effects but had acceptable reliability (Cronbach's Alpha Coefficients were higher than 0.7 in all the subscales except "Daily Activities" in the asthma sample group). There were higher correlation coefficients between items and their hypothesized subscales than those with other subscales. The asthma sample group reported higher parent HRQOL and family functioning than the heart disease sample group. In the heart disease sample group, parents of outpatients reported higher parent HRQOL and family functioning than parents of inpatients. Confirmatory factor analysis showed that the instrument had marginally acceptable construct validity with some Goodness-of-Fit indices not reaching the standard indicating acceptable model fit. The Chinese version of the PedsQL™ Family Impact Module has adequate psychometric properties and could be used to assess the impacts of pediatric asthma or pediatric heart disease on parent HRQOL and family functioning in China. This instrument should be field tested on parents of children with other chronic medical conditions in other areas. Construct validity tested by confirmatory factor analysis and test-retest reliability should be further assessed.
Weech-Maldonado, Robert; Carle, Adam; Weidmer, Beverly; Hurtado, Margarita; Ngo-Metzger, Quyen; Hays, Ron D
2012-09-01
There is a need for reliable and valid measures of cultural competence (CC) from the patient's perspective. This paper evaluates the reliability and validity of the Consumer Assessments of Healthcare Providers and Systems (CAHPS) CC item set. Using 2008 survey data, we assessed the internal consistency of the CAHPS CC scales using the Cronbach α's and examined the validity of the measures using exploratory and confirmatory factor analysis, multitrait scaling analysis, and regression analysis. A random stratified sample (based on race/ethnicity and language) of 991 enrollees, younger than 65 years, from 2 Medicaid managed care plans in California and New York. CAHPS CC item set after excluding screener items and ratings. Confirmatory factor analysis (Comparative Fit Index=0.98, Tucker Lewis Index=0.98, and Root Mean Square Error or Approximation=0.06) provided support for a 7-factor structure: Doctor Communication--Positive Behaviors, Doctor Communication--Negative Behaviors, Doctor Communication--Health Promotion, Doctor Communication--Alternative Medicine, Shared Decision-Making, Equitable Treatment, and Trust. Item-total correlations (corrected for item overlap) for the 7 scales exceeded 0.40. Exploratory factor analysis showed support for 1 additional factor: Access to Interpreter Services. Internal consistency reliability estimates ranged from 0.58 (Alternative Medicine) to 0.92 (Positive Behaviors) and was 0.70 or higher for 4 of the 8 composites. All composites were positively and significantly associated with the overall doctor rating. The CAHPS CC 26-item set demonstrates adequate measurement properties and can be used as a supplemental item set to the CAHPS Clinician and Group Surveys in assessing culturally competent care from the patient's perspective.
Validity and reliability of the Persian version of spatial hearing questionnaire
Delphi, Maryam; Zamiri Abdolahi, Farzaneh; Tyler, Richard; Bakhit, Mahsa; Saki, Nader; Nazeri, Ahmad Reza
2015-01-01
Background: Our hearing ability in space is critical for hearing speech in noisy environment and localization. The Spatial Hearing Questionnaire (SHQ) has been devised to focus only on spatial haring tasks (e.g., lateralization, distance detection and binaural detection). The aim of the present study was to determine the reliability and validity of the Persian translation of the SHQ (Spatial Hearing Questionnaire). Methods: Translation and back-translation, reliability, content and construct validity were investigated. Eighty patients with sensory neural hearing loss (SNHL) (52.50% female and 47.5 % male) with the mean±SD age of 49.02±13.60 years completed SHQ, and they were categorized into mild, moderate, moderate to severe and severe groups based on their hearing threshold. Inclusion criteria in this study were the MMSE questionnaire score of higher than 21, good general health, no history of psychiatric disorders, dizziness or vertigo, dementia or alcohol abuse. Results: The reliability was assessed by Cronbach’s alpha and found to be 0.99. Item-total correlation was between r= 0.84 and 0.92. There was a significant difference between the mean score of PSHQ in the four groups. Based on the factor analysis, two factors were extracted from the questions in P-SHQ: sound localization; and music and speech understanding in noise and quiet. These factors could explain 82.1% and 9.3% of the total variance, respectively. Conclusion: The present study proved the reliability and validity of the Persian version of SHQ (PSHQ). This provides a suitable tool for spatial hearing assessment in clinical/research environments. PMID:26793624
A pilot study examining density of suppression measurement in strabismus.
Piano, Marianne; Newsham, David
2015-01-01
Establish whether the Sbisa bar, Bagolini filter (BF) bar, and neutral density filter (NDF) bar, used to measure density of suppression, are equivalent and possess test-retest reliability. Determine whether density of suppression is altered when measurement equipment/testing conditions are changed. Our pilot study had 10 subjects aged ≥18 years with childhood-onset strabismus, no ocular pathologies, and no binocular vision when manifest. Density of suppression upon repeated testing, with clinic lights on/off, and using a full/reduced intensity light source, was investigated. Results were analysed for test-retest reliability, equivalence, and changes with alteration of testing conditions. Test-retest reliability issues were present for the BF bar (median 6 filter change from first to final test, p = 0.021) and NDF bar (median 5 filter change from first to final test, p = 0.002). Density of suppression was unaffected by environmental illumination or fixation light intensity variations. Density of suppression measurements were higher when measured with the NDF bar (e.g. NDF bar = 1.5, medium suppression, vs BF bar = 6.5, light suppression). Test-retest reliability issues may be present for the two filter bars currently still under manufacture. Changes in testing conditions do not significantly affect test results, provided the same filter bar is used consistently for testing. Further studies in children with strabismus having active amblyopia treatment would be of benefit. Despite extensive use of these tests in the UK, this is to our knowledge the first study evaluating filter bar equivalence/reliability.
Child center closures: Does nonprofit status provide a comparative advantage?
Lam, Marcus; Klein, Sacha; Freisthler, Bridget; Weiss, Robert E
2013-03-01
Reliable access to dependable, high quality childcare services is a vital concern for large numbers of American families. The childcare industry consists of private nonprofit, private for-profit, and governmental providers that differ along many dimensions, including quality, clientele served, and organizational stability. Nonprofit providers are theorized to provide higher quality services given comparative tax advantages, higher levels of consumer trust, and management by mission driven entrepreneurs. This study examines the influence of ownership structure, defined as nonprofit, for-profit sole proprietors, for-profit companies, and governmental centers, on organizational instability, defined as childcare center closures. Using a cross sectional data set of 15724 childcare licenses in California for 2007, we model the predicted closures of childcare centers as a function of ownership structure as well as center age and capacity. Findings indicate that for small centers (capacity of 30 or less) nonprofits are more likely to close, but for larger centers (capacity 30+) nonprofits are less likely to close. This suggests that the comparative advantages available for nonprofit organizations may be better utilized by larger centers than by small centers. We consider the implications of our findings for parents, practitioners, and social policy.
Child center closures: Does nonprofit status provide a comparative advantage?
Lam, Marcus; Klein, Sacha; Freisthler, Bridget; Weiss, Robert E.
2013-01-01
Reliable access to dependable, high quality childcare services is a vital concern for large numbers of American families. The childcare industry consists of private nonprofit, private for-profit, and governmental providers that differ along many dimensions, including quality, clientele served, and organizational stability. Nonprofit providers are theorized to provide higher quality services given comparative tax advantages, higher levels of consumer trust, and management by mission driven entrepreneurs. This study examines the influence of ownership structure, defined as nonprofit, for-profit sole proprietors, for-profit companies, and governmental centers, on organizational instability, defined as childcare center closures. Using a cross sectional data set of 15724 childcare licenses in California for 2007, we model the predicted closures of childcare centers as a function of ownership structure as well as center age and capacity. Findings indicate that for small centers (capacity of 30 or less) nonprofits are more likely to close, but for larger centers (capacity 30+) nonprofits are less likely to close. This suggests that the comparative advantages available for nonprofit organizations may be better utilized by larger centers than by small centers. We consider the implications of our findings for parents, practitioners, and social policy. PMID:23543882
DOT National Transportation Integrated Search
1984-10-01
The Transit Reliability Information Program (TRIP) is a government-initiated program to assist the transit industry in satisfying its need for transit reliability information. TRIP provides this assistance through the operation of a national data ban...
Soldier Dimensions in Combat Models
1990-05-07
and performance. Questionnaires, SQTs, and ARTEPs were often used. Many scales had estimates of reliability but few had validity data. Most studies...pending its validation . Research plans were provided for applications in simulated combat and with simulation devices, for data previously gathered...regarding reliability and validity . Lack of information following an instrument indicates neither reliability nor validity information was provided by the
Bloemen, Manon A T; de Groot, Janke F; Backx, Frank J G; Westerveld, Rosalyne A; Takken, Tim
2015-05-01
To determine the best test performance and feasibility using a Graded Arm Cranking Test vs a Graded Wheelchair Propulsion Test in young people with spina bifida who use a wheelchair, and to determine the reliability of the best test. Validity and reliability study. Young people with spina bifida who use a wheelchair. Physiological responses were measured during a Graded Arm Cranking Test and a Graded Wheelchair Propulsion Test using a heart rate monitor and calibrated mobile gas analysis system (Cortex Metamax). For validity, peak oxygen uptake (VO2peak) and peak heart rate (HRpeak) were compared using paired t-tests. For reliability, the intra-class correlation coefficients, standard error of measurement, and standard detectable change were calculated. VO2peak and HRpeak were higher during wheelchair propulsion compared with arm cranking (23.1 vs 19.5 ml/kg/min, p = 0.11; 165 vs 150 beats/min, p < 0.05). Reliability of wheelchair propulsion showed high intra-class correlation coefficients (ICCs) for both VO2peak (ICC = 0.93) and HRpeak (ICC = 0.90). This pilot study shows higher HRpeak and a tendency to higher VO2peak in young people with spina bifida who are using a wheelchair when tested during wheelchair propulsion compared with arm cranking. Wheelchair propulsion showed good reliability. We recommend performing a wheelchair propulsion test for aerobic fitness testing in this population.
Nutrition Environment Measures Survey in stores (NEMS-S): development and evaluation.
Glanz, Karen; Sallis, James F; Saelens, Brian E; Frank, Lawrence D
2007-04-01
Eating, or nutrition, environments are believed to contribute to obesity and chronic diseases. There is a need for valid, reliable measures of nutrition environments. This article reports on the development and evaluation of measures of nutrition environments in retail food stores. The Nutrition Environment Measures Study developed observational measures of the nutrition environment within retail food stores (NEMS-S) to assess availability of healthy options, price, and quality. After pretesting, measures were completed by independent raters to evaluate inter-rater reliability and across two occasions to assess test-retest reliability in grocery and convenience stores in four neighborhoods differing on income and community design in the Atlanta metropolitan area. Data were collected and analyzed in 2004 and 2005. Ten food categories (e.g., fruits) or indicator food items (e.g., ground beef) were evaluated in 85 stores. Inter-rater reliability and test-retest reliability of availability were high: inter-rater reliability kappas were 0.84 to 1.00, and test-retest reliabilities were .73 to 1.00. Inter-rater reliability for quality across fresh produce was moderate (kappas, 0.44 to 1.00). Healthier options were higher priced for hot dogs, lean ground beef, and baked chips. More healthful options were available in grocery than convenience stores and in stores in higher income neighborhoods. The NEMS-S tool was found to have a high degree of inter-rater and test-retest reliability, and to reveal significant differences across store types and neighborhoods of high and low socioeconomic status. These observational measures of nutrition environments can be applied in multilevel studies of community nutrition, and can inform new approaches to conducting and evaluating nutrition interventions.
De Kegel, A; Dhooge, I; Cambier, D; Baetens, T; Palmans, T; Van Waelvelde, H
2011-04-01
The purpose of this study was to establish test-retest reliability of centre of pressure (COP) measurements obtained by an AccuGait portable forceplate (ACG), mean COG sway velocity measured by a Basic Balance Master (BBM) and clinical balance tests in children with and without balance difficulties. 49 typically developing children and 23 hearing impaired children, with a higher risk for stability problems, between 6 and 12 years of age participated. Each child performed the modified Clinical Test of Sensory Interaction on Balance (mCTSIB), Unilateral Stance (US) and Tandem Stance on ACG, mCTSIB and US on BBM and clinical balance tests: one-leg standing, balance beam walking and one-leg hopping. All subjects completed 2 test sessions on 2 different days in the same week assessed by the same examiner. Among COP measurements obtained by the ACG, mean sway velocity was the most reliable parameter with all ICCs higher than 0.72. The standard deviation (SD) of sway velocity, sway area, SD of anterior-posterior and SD of medio-lateral COP data showed moderate to excellent reliability with ICCs between 0.55 and 0.96 but some caution must be taken into account in some conditions. BBM is less reliable but clinical balance tests are as reliable as ACG. Hearing impaired children exhibited better relative reliability (ICC) and comparable absolute reliability (SEM) for most balance parameters compared to typically developing children. Reliable information regarding postural stability of typically developing children and hearing impaired children may be obtained utilizing COP measurements generated by an AccuGait system and clinical balance tests. Copyright © 2011 Elsevier B.V. All rights reserved.
Age-Related Differences in Test-Retest Reliability in Resting-State Brain Functional Connectivity
Song, Jie; Desphande, Alok S.; Meier, Timothy B.; Tudorascu, Dana L.; Vergun, Svyatoslav; Nair, Veena A.; Biswal, Bharat B.; Meyerand, Mary E.; Birn, Rasmus M.; Bellec, Pierre; Prabhakaran, Vivek
2012-01-01
Resting-state functional MRI (rs-fMRI) has emerged as a powerful tool for investigating brain functional connectivity (FC). Research in recent years has focused on assessing the reliability of FC across younger subjects within and between scan-sessions. Test-retest reliability in resting-state functional connectivity (RSFC) has not yet been examined in older adults. In this study, we investigated age-related differences in reliability and stability of RSFC across scans. In addition, we examined how global signal regression (GSR) affects RSFC reliability and stability. Three separate resting-state scans from 29 younger adults (18–35 yrs) and 26 older adults (55–85 yrs) were obtained from the International Consortium for Brain Mapping (ICBM) dataset made publically available as part of the 1000 Functional Connectomes project www.nitrc.org/projects/fcon_1000. 92 regions of interest (ROIs) with 5 cubic mm radius, derived from the default, cingulo-opercular, fronto-parietal and sensorimotor networks, were previously defined based on a recent study. Mean time series were extracted from each of the 92 ROIs from each scan and three matrices of z-transformed correlation coefficients were created for each subject, which were then used for evaluation of multi-scan reliability and stability. The young group showed higher reliability of RSFC than the old group with GSR (p-value = 0.028) and without GSR (p-value <0.001). Both groups showed a high degree of multi-scan stability of RSFC and no significant differences were found between groups. By comparing the test-retest reliability of RSFC with and without GSR across scans, we found significantly higher proportion of reliable connections in both groups without GSR, but decreased stability. Our results suggest that aging is associated with reduced reliability of RSFC which itself is highly stable within-subject across scans for both groups, and that GSR reduces the overall reliability but increases the stability in both age groups and could potentially alter group differences of RSFC. PMID:23227153
Structural Reliability Analysis and Optimization: Use of Approximations
NASA Technical Reports Server (NTRS)
Grandhi, Ramana V.; Wang, Liping
1999-01-01
This report is intended for the demonstration of function approximation concepts and their applicability in reliability analysis and design. Particularly, approximations in the calculation of the safety index, failure probability and structural optimization (modification of design variables) are developed. With this scope in mind, extensive details on probability theory are avoided. Definitions relevant to the stated objectives have been taken from standard text books. The idea of function approximations is to minimize the repetitive use of computationally intensive calculations by replacing them with simpler closed-form equations, which could be nonlinear. Typically, the approximations provide good accuracy around the points where they are constructed, and they need to be periodically updated to extend their utility. There are approximations in calculating the failure probability of a limit state function. The first one, which is most commonly discussed, is how the limit state is approximated at the design point. Most of the time this could be a first-order Taylor series expansion, also known as the First Order Reliability Method (FORM), or a second-order Taylor series expansion (paraboloid), also known as the Second Order Reliability Method (SORM). From the computational procedure point of view, this step comes after the design point identification; however, the order of approximation for the probability of failure calculation is discussed first, and it is denoted by either FORM or SORM. The other approximation of interest is how the design point, or the most probable failure point (MPP), is identified. For iteratively finding this point, again the limit state is approximated. The accuracy and efficiency of the approximations make the search process quite practical for analysis intensive approaches such as the finite element methods; therefore, the crux of this research is to develop excellent approximations for MPP identification and also different approximations including the higher-order reliability methods (HORM) for representing the failure surface. This report is divided into several parts to emphasize different segments of the structural reliability analysis and design. Broadly, it consists of mathematical foundations, methods and applications. Chapter I discusses the fundamental definitions of the probability theory, which are mostly available in standard text books. Probability density function descriptions relevant to this work are addressed. In Chapter 2, the concept and utility of function approximation are discussed for a general application in engineering analysis. Various forms of function representations and the latest developments in nonlinear adaptive approximations are presented with comparison studies. Research work accomplished in reliability analysis is presented in Chapter 3. First, the definition of safety index and most probable point of failure are introduced. Efficient ways of computing the safety index with a fewer number of iterations is emphasized. In chapter 4, the probability of failure prediction is presented using first-order, second-order and higher-order methods. System reliability methods are discussed in chapter 5. Chapter 6 presents optimization techniques for the modification and redistribution of structural sizes for improving the structural reliability. The report also contains several appendices on probability parameters.
Evaluation of Reliability Coefficients for Two-Level Models via Latent Variable Analysis
ERIC Educational Resources Information Center
Raykov, Tenko; Penev, Spiridon
2010-01-01
A latent variable analysis procedure for evaluation of reliability coefficients for 2-level models is outlined. The method provides point and interval estimates of group means' reliability, overall reliability of means, and conditional reliability. In addition, the approach can be used to test simple hypotheses about these parameters. The…
DOT National Transportation Integrated Search
1981-08-01
The Transit Reliability Information Program (TRIP) is a government-initiated program to assist the transit industry in satisfying its need for transit reliability information. TRIP provides this assistance through the operation of a national Data Ban...
Data mining-based coefficient of influence factors optimization of test paper reliability
NASA Astrophysics Data System (ADS)
Xu, Peiyao; Jiang, Huiping; Wei, Jieyao
2018-05-01
Test is a significant part of the teaching process. It demonstrates the final outcome of school teaching through teachers' teaching level and students' scores. The analysis of test paper is a complex operation that has the characteristics of non-linear relation in the length of the paper, time duration and the degree of difficulty. It is therefore difficult to optimize the coefficient of influence factors under different conditions in order to get text papers with clearly higher reliability with general methods [1]. With data mining techniques like Support Vector Regression (SVR) and Genetic Algorithm (GA), we can model the test paper analysis and optimize the coefficient of impact factors for higher reliability. It's easy to find that the combination of SVR and GA can get an effective advance in reliability from the test results. The optimal coefficient of influence factors optimization has a practicability in actual application, and the whole optimizing operation can offer model basis for test paper analysis.
Quality of nursing doctoral education in Korea: towards policy development.
Ja Kim, Mi; Gi Park, Chang; Kim, Minju; Lee, Hyeonkyeong; Ahn, Yang-Heui; Kim, Euisook; Yun, Soon-Nyoung; Lee, Kwang-Ja
2012-07-01
This article is a report on an international study of the quality of nursing doctoral education; herein, we report findings for Korea. Specific aims were to: examine the validity and reliability of the quality of nursing doctoral education questionnaire; and identify contributing factors and domain(s) for improvement. The quality of nursing doctoral education has been a worldwide concern with the recent rapid increase in number of nursing doctoral programmes around the world, and comprehensive evaluation is needed for policy recommendations. A cross-sectional descriptive study, conducted from October 2006 to January 2007, used an online questionnaire evaluating four domains: programme, faculty, resources and evaluation. Seven deans, 48 faculty, 52 graduates and 87 students from 14 nursing schools participated. Content and construct validity, and construct reliability of the questionnaire were established. Overall, participants reported that the perceived quality of private universities/schools was significantly higher than that of public/national universities. A higher ratio of doctoral to non-doctoral students was significantly associated with higher quality. The domains of programme, faculty and resources were highly correlated. The programme was the most important domain; availability of sufficient materials and information for students most needed improvement. Overall, faculty perceived the quality of the programme, faculty and resources as more positively than did the graduates and students. This study provides useful policy guidance for nurse educators worldwide for improving doctoral programmes and faculty's role in educating students. Further study is recommended that examines contributing factors to quality doctoral education. © 2011 Blackwell Publishing Ltd.
Surfing Behind a Boat: Quality and Reliability of Online Resources on Scaphoid Fractures.
Nassiri, Mujtaba; Mohamed, Osama; Berzins, Arvids; Aljabi, Yasser; Mahmood, Talat; Chenouri, Shojaeddin; O'Grady, Paul
2016-10-01
Patients seeking information and advice on treatment of scaphoid fractures unknowingly confront longstanding medical controversies surrounding the management of this condition. However, there are no studies specifically looking into the quality and reliability of online information on scaphoid fractures. We identified 44 unique websites for evaluation using the term "scaphoid fractures". The websites were categorized by type and assessed using the DISCERN score, the Journal of the American Medical Association (JAMA) benchmark criteria and the Health on the net (HON) code. The majority of websites were commercial (n = 13) followed by academic (n = 12). Only seven of the websites were HON certified. The mean DISCERN score was 43.8. Only 4 websites scored 63 or above representing excellent quality with minimal shortcomings but 13 websites scored 38 or below representing poor or very poor quality. The mean JAMA benchmark criteria score was 2.2. The Governmental and Non-Profit Organizations category websites had the highest mean JAMA benchmark score. The websites that displayed the HON-code seal had higher mean DISCERN scores and higher mean JAMA benchmark scores compared to websites that did not display the seal. Good quality health information is certainly available on the Internet. However, it is not possible to predict with certainty which sites are of higher quality. We suggest clinicians should have a responsibility to educate their patients regarding the unregulated nature of medical information on the internet and proactively provide patients with educational resources and thus help them make smart and informed decisions.
Space Transportation System Availability Relationships to Life Cycle Cost
NASA Technical Reports Server (NTRS)
Rhodes, Russel E.; Donahue, Benjamin B.; Chen, Timothy T.
2009-01-01
Future space transportation architectures and designs must be affordable. Consequently, their Life Cycle Cost (LCC) must be controlled. For the LCC to be controlled, it is necessary to identify all the requirements and elements of the architecture at the beginning of the concept phase. Controlling LCC requires the establishment of the major operational cost drivers. Two of these major cost drivers are reliability and maintainability, in other words, the system's availability (responsiveness). Potential reasons that may drive the inherent availability requirement are the need to control the number of unique parts and the spare parts required to support the transportation system's operation. For more typical space transportation systems used to place satellites in space, the productivity of the system will drive the launch cost. This system productivity is the resultant output of the system availability. Availability is equal to the mean uptime divided by the sum of the mean uptime plus the mean downtime. Since many operational factors cannot be projected early in the definition phase, the focus will be on inherent availability which is equal to the mean time between a failure (MTBF) divided by the MTBF plus the mean time to repair (MTTR) the system. The MTBF is a function of reliability or the expected frequency of failures. When the system experiences failures the result is added operational flow time, parts consumption, and increased labor with an impact to responsiveness resulting in increased LCC. The other function of availability is the MTTR, or maintainability. In other words, how accessible is the failed hardware that requires replacement and what operational functions are required before and after change-out to make the system operable. This paper will describe how the MTTR can be equated to additional labor, additional operational flow time, and additional structural access capability, all of which drive up the LCC. A methodology will be presented that provides the decision makers with the understanding necessary to place constraints on the design definition. This methodology for the major drivers will determine the inherent availability, safety, reliability, maintainability, and the life cycle cost of the fielded system. This methodology will focus on the achievement of an affordable, responsive space transportation system. It is the intent of this paper to not only provide the visibility of the relationships of these major attribute drivers (variables) to each other and the resultant system inherent availability, but also to provide the capability to bound the variables, thus providing the insight required to control the system's engineering solution. An example of this visibility is the need to provide integration of similar discipline functions to allow control of the total parts count of the space transportation system. Also, selecting a reliability requirement will place a constraint on parts count to achieve a given inherent availability requirement, or require accepting a larger parts count with the resulting higher individual part reliability requirements. This paper will provide an understanding of the relationship of mean repair time (mean downtime) to maintainability (accessibility for repair), and both mean time between failure (reliability of hardware) and the system inherent availability.
NASA Astrophysics Data System (ADS)
Llopis-Albert, Carlos; Palacios-Marqués, Daniel; Merigó, José M.
2014-04-01
In this paper a methodology for the stochastic management of groundwater quality problems is presented, which can be used to provide agricultural advisory services. A stochastic algorithm to solve the coupled flow and mass transport inverse problem is combined with a stochastic management approach to develop methods for integrating uncertainty; thus obtaining more reliable policies on groundwater nitrate pollution control from agriculture. The stochastic inverse model allows identifying non-Gaussian parameters and reducing uncertainty in heterogeneous aquifers by constraining stochastic simulations to data. The management model determines the spatial and temporal distribution of fertilizer application rates that maximizes net benefits in agriculture constrained by quality requirements in groundwater at various control sites. The quality constraints can be taken, for instance, by those given by water laws such as the EU Water Framework Directive (WFD). Furthermore, the methodology allows providing the trade-off between higher economic returns and reliability in meeting the environmental standards. Therefore, this new technology can help stakeholders in the decision-making process under an uncertainty environment. The methodology has been successfully applied to a 2D synthetic aquifer, where an uncertainty assessment has been carried out by means of Monte Carlo simulation techniques.
Yan, Zhixiang; Li, Tianxue; Lv, Pin; Li, Xiang; Zhou, Chen; Yang, Xinghao
2013-06-01
There is a growing need both clinically and experimentally to improve the determination of the blood levels of multiple chemical constituents in herbal medicines. The conventional multiple reaction monitoring (cMRM), however, is not well suited for multi-component determination and could not provide qualitative information for identity confirmation. Here we apply a dynamic triggered MRM (DtMRM) algorithm for the quantification of 20 constituents in an herbal prescription Bu-Zhong-Yi-Qi-Tang (BZYQT) in rat plasma. Dynamic MRM (DMRM) dramatically reduced the number of concurrent MRM transitions that are monitored during each MS scan. This advantage has been enhanced with the addition of triggered MRM (tMRM) for simultaneous confirmation, which maximizes the dwell time in the primary MRM quantitation phase, and also acquires sufficient MRM data to create a composite product ion spectrum. By allowing optimized collision energy for each product ion and maximizing dwell times, tMRM is significantly more sensitive and reliable than conventional product ion scanning. The DtMRM approach provides much higher sensitivity and reproducibility than cMRM. Copyright © 2013 Elsevier B.V. All rights reserved.
Cerin, Ester; Sit, Cindy H P; Huang, Ya-Jun; Barnett, Anthony; Macfarlane, Duncan J; Wong, Stephen S H
2014-06-06
Physical activity and sedentary behaviour are important contributors to adolescents' health. These behaviours may be affected by the school and neighbourhood built environments. However, current evidence on such effects is mainly limited to Western countries. The International Physical Activity and the Environment Network (IPEN)-Adolescent study aims to examine associations of the built environment with adolescent physical activity and sedentary behaviour across five continents.We report on the repeatability of measures of in-school and out-of school physical activity, plus measures of out-of-school sedentary and travel behaviours adopted by the IPEN - Adolescent study and adapted for Chinese-speaking Hong Kong adolescents participating in the international Healthy environments and active living in teenagers-(Hong Kong) [iHealt(H)] study, which is part of IPEN-Adolescent. Items gauging in-school physical activity and out-of-school physical activity, and out-of-school sedentary and travel behaviours developed for the IPEN - Adolescent study were translated from English into Chinese, adapted, and pilot tested. Sixty-eight Chinese-speaking 12-17 year old secondary school students (36 boys; 32 girls) residing in areas of Hong Kong differing in transport-related walkability were recruited. They self-completed the survey items twice, 8-16 days apart. Test-retest reliability was assessed for the whole sample and by gender using one-way random effects intra-class correlation coefficients (ICC). Test-retest reliability of items with restricted variability was assessed using percentage agreement. Overall test-retest reliability of items and scales was moderate to excellent (ICC = 0.47-0.92). Items with restricted variability in responses had a high percentage agreement (92%-100%). Test-retest reliability was similar in girls and boys, with the exception of daily hours of homework (reliability higher in girls) and number of school-based sports teams or after-school physical activity classes (reliability higher in boys). The translated and adapted self-report measures of physical activity, sedentary and travel behaviours used in the iHealt(H) study are sufficiently reliable. Levels of reliability are comparable or slightly higher than those observed for the original measures.
Lee, Won-Jeong; Choi, Byung-Soon
2013-06-01
The aim of this study was to evaluate the reliability and validity of soft copy images based on flat-panel detector of digital radiography (DR-FPD soft copy images) compared to analog radiographs (ARs) in pneumoconiosis classification and diagnosis. DR-FPD soft copy images and ARs from 349 subjects were independently read by four-experienced readers according to the International Labor Organization 2000 guidelines. DR-FPD soft copy images were used to obtain consensus reading (CR) by all readers as the gold standard. Reliability and validity were evaluated by a κ and receiver operating characteristic analysis, respectively. In small opacity, overall interreader agreement of DR-FPD soft copy images was significantly higher than that of ARs, but it was not significantly different in large opacity and costophrenic angle obliteration. In small opacity, agreement of DR-FPD soft copy images with CR was significantly higher than that of ARs with CR. It was also higher than that of ARs with CR in pleural plaque and thickening. Receiver operating characteristic areas were not different significantly between DR-FPD soft copy images and ARs. DR-FPD soft copy images showed accurate and reliable results in pneumoconiosis classification and diagnosis compared to ARs. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.
Test-retest reliability of functional connectivity networks during naturalistic fMRI paradigms.
Wang, Jiahui; Ren, Yudan; Hu, Xintao; Nguyen, Vinh Thai; Guo, Lei; Han, Junwei; Guo, Christine Cong
2017-04-01
Functional connectivity analysis has become a powerful tool for probing the human brain function and its breakdown in neuropsychiatry disorders. So far, most studies adopted resting-state paradigm to examine functional connectivity networks in the brain, thanks to its low demand and high tolerance that are essential for clinical studies. However, the test-retest reliability of resting-state connectivity measures is moderate, potentially due to its low behavioral constraint. On the other hand, naturalistic neuroimaging paradigms, an emerging approach for cognitive neuroscience with high ecological validity, could potentially improve the reliability of functional connectivity measures. To test this hypothesis, we characterized the test-retest reliability of functional connectivity measures during a natural viewing condition, and benchmarked it against resting-state connectivity measures acquired within the same functional magnetic resonance imaging (fMRI) session. We found that the reliability of connectivity and graph theoretical measures of brain networks is significantly improved during natural viewing conditions over resting-state conditions, with an average increase of almost 50% across various connectivity measures. Not only sensory networks for audio-visual processing become more reliable, higher order brain networks, such as default mode and attention networks, but also appear to show higher reliability during natural viewing. Our results support the use of natural viewing paradigms in estimating functional connectivity of brain networks, and have important implications for clinical application of fMRI. Hum Brain Mapp 38:2226-2241, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Update on MTTF figures for linear and rotary coolers of Thales Cryogenics
NASA Astrophysics Data System (ADS)
van de Groep, W.; van der Weijden, H.; van Leeuwen, R.; Benschop, T.; Cauquil, J. M.; Griot, R.
2012-06-01
Thales Cryogenics has an extensive background in delivering linear and rotary coolers for military, civil and space programs. During the last years several technical improvements have increased the lifetime of all Thales coolers resulting in significantly higher Mean Time To Failure (MTTF) figures. In this paper not only updated MTTF values for most of the products in our portfolio will be presented but also the methodology used to come to these reliability figures will be explained. The differences between rotary and linear coolers will be highlighted including the different failure modes influencing the lifetime under operational conditions. These updated reliability figures are based on extensive test results for both rotary and linear coolers as well as Weibull analysis, failure mode identifications, various types of lifetime testing and field results of operational coolers. The impact of the cooler selection for typical applications will be outlined. This updated reliability approach will enable an improved tradeoff for cooler selection in applications where MTTF and a correct reliability assessment is key. Improbing on cooler selection and an increased insight in cooler reliability will result in a higher uptime and operability of equipment, less risk on unexpected failures and lower costs of ownership.
Petrova, Tatjana; Kavookjian, Jan; Madson, Michael B; Dagley, John; Shannon, David; McDonough, Sharon K
2015-01-01
Motivational interviewing (MI) has demonstrated a significant impact as an intervention strategy for addiction management, change in lifestyle behaviors, and adherence to prescribed medication and other treatments. Key elements to studying MI include training in MI of professionals who will use it, assessment of skills acquisition in trainees, and the use of a validated skills assessment tool. The purpose of this research project was to develop a psychometrically valid and reliable tool that has been designed to assess MI skills competence in health care provider trainees. The goal was to develop an assessment tool that would evaluate the acquisition and use of specific MI skills and principles, as well as the quality of the patient-provider therapeutic alliance in brief health care encounters. To address this purpose, specific steps were followed, beginning with a literature review. This review contributed to the development of relevant conceptual and operational definitions, selecting a scaling technique and response format, and methods for analyzing validity and reliability. Internal consistency reliability was established on 88 video recorded interactions. The inter-rater and test-retest reliability were established using randomly selected 18 from the 88 interactions. The assessment tool Motivational Interviewing Skills for Health Care Encounters (MISHCE) and a manual for use of the tool were developed. Validity and reliability of MISHCE were examined. Face and content validity were supported with well-defined conceptual and operational definitions and feedback from an expert panel. Reliability was established through internal consistency, inter-rater reliability, and test-retest reliability. The overall internal consistency reliability (Cronbach's alpha) for all fifteen items was 0.75. MISHCE demonstrated good inter-rater reliability and good to excellent test-retest reliability. MISHCE assesses the health provider's level of knowledge and skills in brief disease management encounters. MISHCE also evaluates quality of the patient-provider therapeutic alliance, i.e., the "flow" of the interaction. Copyright © 2015 Elsevier Inc. All rights reserved.
Agreement and accuracy using the FIGO, ACOG and NICE cardiotocography interpretation guidelines.
Santo, Susana; Ayres-de-Campos, Diogo; Costa-Santos, Cristina; Schnettler, William; Ugwumadu, Austin; Da Graça, Luís M
2017-02-01
One of the limitations reported with cardiotocography is the modest interobserver agreement observed in tracing interpretation. This study compared agreement, reliability and accuracy of cardiotocography interpretation using the International Federation of Gynecology and Obstetrics, American College of Obstetrics and Gynecology and National Institute for Health and Care Excellence guidelines. A total of 151 tracings were evaluated by 27 clinicians from three centers where International Federation of Gynecology and Obstetrics, American College of Obstetrics and Gynecology and National Institute for Health and Care Excellence guidelines were routinely used. Interobserver agreement was evaluated using the proportions of agreement and reliability with the κ statistic. The accuracy of tracings classified as "pathological/category III" was assessed for prediction of newborn acidemia. For all measures, 95% confidence interval were calculated. Cardiotocography classifications were more distributed with International Federation of Gynecology and Obstetrics (9, 52, 39%) and National Institute for Health and Care Excellence (30, 33, 37%) than with American College of Obstetrics and Gynecology (13, 81, 6%). The category with the highest agreement was American College of Obstetrics and Gynecology category II (proportions of agreement = 0.73, 95% confidence interval 0.70-76), and the ones with the lowest agreement were American College of Obstetrics and Gynecology categories I and III. Reliability was significantly higher with International Federation of Gynecology and Obstetrics (κ = 0.37, 95% confidence interval 0.31-0.43), and National Institute for Health and Care Excellence (κ = 0.33, 95% confidence interval 0.28-0.39) than with American College of Obstetrics and Gynecology (κ = 0.15, 95% confidence interval 0.10-0.21); however, all represent only slight/fair reliability. International Federation of Gynecology and Obstetrics and National Institute for Health and Care Excellence showed a trend towards higher sensitivities in prediction of newborn acidemia (89 and 97%, respectively) than American College of Obstetrics and Gynecology (32%), but the latter achieved a significantly higher specificity (95%). With American College of Obstetrics and Gynecology guidelines there is high agreement in category II, low reliability, low sensitivity and high specificity in prediction of acidemia. With International Federation of Gynecology and Obstetrics and National Institute for Health and Care Excellence guidelines there is higher reliability, a trend towards higher sensitivity, and lower specificity in prediction of acidemia. © 2016 Nordic Federation of Societies of Obstetrics and Gynecology.
Structural materials issues for the next generation fission reactors
NASA Astrophysics Data System (ADS)
Chant, I.; Murty, K. L.
2010-09-01
Generation-IV reactor design concepts envisioned thus far cater to a common goal of providing safer, longer lasting, proliferation-resistant, and economically viable nuclear power plants. The foremost consideration in the successful development and deployment of Gen-W reactor systems is the performance and reliability issues involving structural materials for both in-core and out-of-core applications. The structural materials need to endure much higher temperatures, higher neutron doses, and extremely corrosive environments, which are beyond the experience of the current nuclear power plants. Materials under active consideration for use in different reactor components include various ferritic/martensitic steels, austenitic stainless steels, nickel-base superalloys, ceramics, composites, etc. This article addresses the material requirements for these advanced fission reactor types, specifically addressing structural materials issues depending on the specific application areas.
NASA Astrophysics Data System (ADS)
Marro, Massimo; Salizzoni, Pietro; Soulhac, Lionel; Cassiani, Massimo
2018-06-01
We analyze the reliability of the Lagrangian stochastic micromixing method in predicting higher-order statistics of the passive scalar concentration induced by an elevated source (of varying diameter) placed in a turbulent boundary layer. To that purpose we analyze two different modelling approaches by testing their results against the wind-tunnel measurements discussed in Part I (Nironi et al., Boundary-Layer Meteorology, 2015, Vol. 156, 415-446). The first is a probability density function (PDF) micromixing model that simulates the effects of the molecular diffusivity on the concentration fluctuations by taking into account the background particles. The second is a new model, named VPΓ, conceived in order to minimize the computational costs. This is based on the volumetric particle approach providing estimates of the first two concentration moments with no need for the simulation of the background particles. In this second approach, higher-order moments are computed based on the estimates of these two moments and under the assumption that the concentration PDF is a Gamma distribution. The comparisons concern the spatial distribution of the first four moments of the concentration and the evolution of the PDF along the plume centreline. The novelty of this work is twofold: (i) we perform a systematic comparison of the results of micro-mixing Lagrangian models against experiments providing profiles of the first four moments of the concentration within an inhomogeneous and anisotropic turbulent flow, and (ii) we show the reliability of the VPΓ model as an operational tool for the prediction of the PDF of the concentration.
NASA Astrophysics Data System (ADS)
Marro, Massimo; Salizzoni, Pietro; Soulhac, Lionel; Cassiani, Massimo
2018-01-01
We analyze the reliability of the Lagrangian stochastic micromixing method in predicting higher-order statistics of the passive scalar concentration induced by an elevated source (of varying diameter) placed in a turbulent boundary layer. To that purpose we analyze two different modelling approaches by testing their results against the wind-tunnel measurements discussed in Part I (Nironi et al., Boundary-Layer Meteorology, 2015, Vol. 156, 415-446). The first is a probability density function (PDF) micromixing model that simulates the effects of the molecular diffusivity on the concentration fluctuations by taking into account the background particles. The second is a new model, named VPΓ, conceived in order to minimize the computational costs. This is based on the volumetric particle approach providing estimates of the first two concentration moments with no need for the simulation of the background particles. In this second approach, higher-order moments are computed based on the estimates of these two moments and under the assumption that the concentration PDF is a Gamma distribution. The comparisons concern the spatial distribution of the first four moments of the concentration and the evolution of the PDF along the plume centreline. The novelty of this work is twofold: (i) we perform a systematic comparison of the results of micro-mixing Lagrangian models against experiments providing profiles of the first four moments of the concentration within an inhomogeneous and anisotropic turbulent flow, and (ii) we show the reliability of the VPΓ model as an operational tool for the prediction of the PDF of the concentration.
Robotic Prostatectomy on the Web: A Cross-Sectional Qualitative Assessment.
Borgmann, Hendrik; Mager, René; Salem, Johannes; Bründl, Johannes; Kunath, Frank; Thomas, Christian; Haferkamp, Axel; Tsaur, Igor
2016-08-01
Many patients diagnosed with prostate cancer search for information on robotic prostatectomy (RobP) on the Web. We aimed to evaluate the qualitative characteristics of the mostly frequented Web sites on RobP with a particular emphasis on provider-dependent issues. Google was searched for the term "robotic prostatectomy" in Europe and North America. The mostly frequented Web sites were selected and classified as physician-provided and publically-provided. Quality was measured using Journal of the American Medical Association (JAMA) benchmark criteria, DISCERN score, and addressing of Trifecta surgical outcomes. Popularity was analyzed using Google PageRank and Alexa tool. Accessibility, usability, and reliability were investigated using the LIDA tool and readability was assessed using readability indices. Twenty-eight Web sites were physician-provided and 15 publically-provided. For all Web sites, 88% of JAMA benchmark criteria were fulfilled, DISCERN quality score was high, and 81% of Trifecta outcome measurements were addressed. Popularity was average according to Google PageRank (mean 2.9 ± 1.5) and Alexa Traffic Rank (median, 49,109; minimum, 7; maximum, 8,582,295). Accessibility (85 ± 7%), usability (92 ± 3%), and reliability scores (88 ± 8%) were moderate to high. Automated Readability Index was 7.2 ± 2.1 and Flesch-Kincaid Grade Level was 9 ± 2, rating the Web sites as difficult to read. Physician-provided Web sites had higher quality scores and lower readability compared with publically-provided Web sites. Websites providing information on RobP obtained medium to high ratings in all domains of quality in the current assessment. In contrast, readability needs to be significantly improved so that this content can become available for the populace. Copyright © 2015 Elsevier Inc. All rights reserved.
Marker, Ryan J; Balter, Jaclyn E; Nofsinger, Micaela L; Anton, Dan; Fethke, Nathan B; Maluf, Katrina S
2016-09-01
Patterns of cervical muscle activity may contribute to overuse injuries in office workers. The purpose of this investigation was to characterise patterns of upper trapezius muscle activity in pain-free office workers using traditional occupational exposure measures and a modified Active Amplitude Probability Distribution Function (APDF), which considers only periods of active muscle contraction. Bilateral trapezius muscle activity was recorded in 77 pain-free office workers for 1-2 full days in their natural work environment. Mean amplitude, gap frequency, muscular rest and Traditional and Active APDF amplitudes were calculated. All measures demonstrated fair to substantial reliability. Dominant muscles demonstrated higher amplitudes of activity and less muscular rest compared to non-dominant, and women demonstrated less muscular rest with no significant difference in amplitude assessed by Active APDF compared to men. These findings provide normative data to identify atypical motor patterns that may contribute to persistence or recurrence of neck pain in office workers. Practitioner Summary: Upper trapezius muscle activity was characterised in a large cohort of pain-free workers using electromyographic recordings from office environments. Dominant muscles demonstrated higher activity and less rest than non-dominant, and women demonstrated less rest than men. Results may be used to identify atypical trapezius muscle activity in office workers.
Refined generalized multiscale entropy analysis for physiological signals
NASA Astrophysics Data System (ADS)
Liu, Yunxiao; Lin, Youfang; Wang, Jing; Shang, Pengjian
2018-01-01
Multiscale entropy analysis has become a prevalent complexity measurement and been successfully applied in various fields. However, it only takes into account the information of mean values (first moment) in coarse-graining procedure. Then generalized multiscale entropy (MSEn) considering higher moments to coarse-grain a time series was proposed and MSEσ2 has been implemented. However, the MSEσ2 sometimes may yield an imprecise estimation of entropy or undefined entropy, and reduce statistical reliability of sample entropy estimation as scale factor increases. For this purpose, we developed the refined model, RMSEσ2, to improve MSEσ2. Simulations on both white noise and 1 / f noise show that RMSEσ2 provides higher entropy reliability and reduces the occurrence of undefined entropy, especially suitable for short time series. Besides, we discuss the effect on RMSEσ2 analysis from outliers, data loss and other concepts in signal processing. We apply the proposed model to evaluate the complexity of heartbeat interval time series derived from healthy young and elderly subjects, patients with congestive heart failure and patients with atrial fibrillation respectively, compared to several popular complexity metrics. The results demonstrate that RMSEσ2 measured complexity (a) decreases with aging and diseases, and (b) gives significant discrimination between different physiological/pathological states, which may facilitate clinical application.
Choi, Keum-Hyeong; Buskey, Wendy; Johnson, Bonita
2010-07-01
The main purpose of this study was to investigate how receiving personal counseling at a university counseling center helps students deal with their personal problems and facilitates academic functioning. To that end, this study used both clinical and academic outcome measures that are relevant to the practice of counseling provided at a counseling center and its unique function in an institution of higher education. In addition, this study used the clinical significance methodology (N. S. Jacobson & P. Truax, 1991) that takes into account clients' differences in making clinically reliable and significant change. Pre-intake and post-termination surveys, including the Outcome Questionnaire (M. J. Lambert, K. Lunnen, V. Umphress, N. Hansen, & G. Burlingame, 1994), were completed by 78 clients, and the responses were analyzed using clinical significance methodology. The results revealed that those who made clinically reliable and significant change (i.e., the recovered group) reported the highest level of improvement in academic commitment to their educational goals and problem resolution, compared with those who did not make clinically significant change. The implications of the findings on practice for counseling at university counseling centers and for administrators in higher education institutions are discussed. (c) 2010 APA, all rights reserved.
Reliability Considerations for the Operation of Large Accelerator User Facilities
Willeke, F. J.
2016-01-29
The lecture provides an overview of considerations relevant for achieving highly reliable operation of accelerator based user facilities. The article starts with an overview of statistical reliability formalism which is followed by high reliability design considerations with examples. Finally, the article closes with operational aspects of high reliability such as preventive maintenance and spares inventory.
Perspectives of different type biological life support systems (BLSS) usage in space missions
NASA Astrophysics Data System (ADS)
Bartsev, S. I.; Gitelson, J. I.; Lisovsky, G. M.; Mezhevikin, V. V.; Okhonin, V. A.
1996-10-01
In the paper an attempt is made to combine three important criteria of LSS comparison: minimum mass, maximum safety and maximum quality of life. Well-known types of BLSS were considered: with higher plant, higher plants and mushrooms, microalgae, and hydrogen-oxidizing bacteria. These BLSSs were compared in terms of "integrated" mass for the case of a vegetarian diet and a "normal" one (with animal proteins and fats). It was shown that the BLSS with higher plants and incineration of wastes becomes the best when the exploitation period is more than 1 yr. The dependence of higher plants' LSS structure on operation time was found. Comparison of BLSSs in terms of integral reliability (this criterion includes mass and quality of life criteria) for a lunar base scenario showed that BLSSs with higher plants are advantageous in reliability and comfort. This comparison was made for achieved level of technology of closing and for perspective one.
Test Reliability at the Individual Level
Hu, Yueqin; Nesselroade, John R.; Erbacher, Monica K.; Boker, Steven M.; Burt, S. Alexandra; Keel, Pamela K.; Neale, Michael C.; Sisk, Cheryl L.; Klump, Kelly
2016-01-01
Reliability has a long history as one of the key psychometric properties of a test. However, a given test might not measure people equally reliably. Test scores from some individuals may have considerably greater error than others. This study proposed two approaches using intraindividual variation to estimate test reliability for each person. A simulation study suggested that the parallel tests approach and the structural equation modeling approach recovered the simulated reliability coefficients. Then in an empirical study, where forty-five females were measured daily on the Positive and Negative Affect Schedule (PANAS) for 45 consecutive days, separate estimates of reliability were generated for each person. Results showed that reliability estimates of the PANAS varied substantially from person to person. The methods provided in this article apply to tests measuring changeable attributes and require repeated measures across time on each individual. This article also provides a set of parallel forms of PANAS. PMID:28936107
Reliability in the DSM-III field trials: interview v case summary.
Hyler, S E; Williams, J B; Spitzer, R L
1982-11-01
A study compared the reliability of psychiatric diagnoses obtained from the live interviews and from case summaries, on the same patients, by the same clinicians, using the same DSM-III diagnostic criteria. The results showed that the reliability of the major diagnostic classes of DSM-III was higher when diagnoses were made from live interviews than when they were made from case summaries. We conclude that diagnoses based on information contained in traditionally prepared case summaries may lead to an underestimation of the reliability of diagnoses made based on information collected during a "live" interview.
The Youth Throwing Score: Validating Injury Assessment in Young Baseball Players.
Ahmad, Christopher S; Padaki, Ajay S; Noticewala, Manish S; Makhni, Eric C; Popkin, Charles A
2017-02-01
Epidemic levels of shoulder and elbow injuries have been reported recently in youth and adolescent baseball players. Despite the concerning frequency of these injuries, no instrument has been validated to assess upper extremity injury in this patient population. Purpose/Hypothesis: The purpose of this study was to validate an upper extremity assessment tool specifically designed for young baseball players. We hypothesized that this tool will be both reliable and valid. Cohort study (diagnosis); Level of evidence, 2. The Youth Throwing Score (YTS) was constructed by an interdisciplinary team of providers and coaches as a tool to assess upper extremity injury in youth and adolescent baseball players (age range, 10-18 years). The psychometric properties of the test were then determined. A total of 223 players completed the final survey. The players' mean age was 14.3 ± 2.7 years. Pilot analysis showed that none of the 14 questions received a mean athlete importance rating less than 3 of 5, and the final survey read at a Flesch-Kincaid level of 4.1, which is appropriate for patients aged 9 years and older. The players self-assigned their injury status, resulting in a mean instrument score of 59.7 ± 8.4 for the 148 players "playing without pain," 42.0 ± 11.5 for the 60 players "playing with pain," and 40.4 ± 10.5 for the 15 players "not playing due to pain." Players playing without pain scored significantly higher than those playing with pain and those not playing due to pain ( P < .001). Psychometric analysis showed a test-retest intraclass correlation coefficient of 0.90 and a Cronbach alpha intra-item reliability coefficient of 0.93, indicating excellent reliability and internal consistency. Pearson correlation coefficients of 0.65, 0.62, and 0.31 were calculated between the YTS and the Pediatric Outcomes Data Collection Instrument sports/physical functioning module, the Kerlan-Jobe Orthopaedic Clinic Shoulder and Elbow score, and the Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH) score, respectively. Injured players scored a mean of 9.4 points higher after treatment ( P < .001), and players who improved in their self-assigned pain categorization scored 16.5 points higher ( P < .001). The YTS is the first valid and reliable instrument for assessing young baseball players' upper extremity health.
2013-01-01
Background In recent years response rates on telephone surveys have been declining. Rates for the behavioral risk factor surveillance system (BRFSS) have also declined, prompting the use of new methods of weighting and the inclusion of cell phone sampling frames. A number of scholars and researchers have conducted studies of the reliability and validity of the BRFSS estimates in the context of these changes. As the BRFSS makes changes in its methods of sampling and weighting, a review of reliability and validity studies of the BRFSS is needed. Methods In order to assess the reliability and validity of prevalence estimates taken from the BRFSS, scholarship published from 2004–2011 dealing with tests of reliability and validity of BRFSS measures was compiled and presented by topics of health risk behavior. Assessments of the quality of each publication were undertaken using a categorical rubric. Higher rankings were achieved by authors who conducted reliability tests using repeated test/retest measures, or who conducted tests using multiple samples. A similar rubric was used to rank validity assessments. Validity tests which compared the BRFSS to physical measures were ranked higher than those comparing the BRFSS to other self-reported data. Literature which undertook more sophisticated statistical comparisons was also ranked higher. Results Overall findings indicated that BRFSS prevalence rates were comparable to other national surveys which rely on self-reports, although specific differences are noted for some categories of response. BRFSS prevalence rates were less similar to surveys which utilize physical measures in addition to self-reported data. There is very little research on reliability and validity for some health topics, but a great deal of information supporting the validity of the BRFSS data for others. Conclusions Limitations of the examination of the BRFSS were due to question differences among surveys used as comparisons, as well as mode of data collection differences. As the BRFSS moves to incorporating cell phone data and changing weighting methods, a review of reliability and validity research indicated that past BRFSS landline only data were reliable and valid as measured against other surveys. New analyses and comparisons of BRFSS data which include the new methodologies and cell phone data will be needed to ascertain the impact of these changes on estimates in the future. PMID:23522349
Creating Highly Reliable Accountable Care Organizations.
Vogus, Timothy J; Singer, Sara J
2016-12-01
Accountable Care Organizations' (ACOs) pursuit of the triple aim of higher quality, lower cost, and improved population health has met with mixed results. To improve the design and implementation of ACOs we look to organizations that manage similarly complex, dynamic, and tightly coupled conditions while sustaining exceptional performance known as high-reliability organizations. We describe the key processes through which organizations achieve reliability, the leadership and organizational practices that enable it, and the role that professionals can play when charged with enacting it. Specifically, we present concrete practices and processes from health care organizations pursuing high-reliability and from early ACOs to illustrate how the triple aim may be met by cultivating mindful organizing, practicing reliability-enhancing leadership, and identifying and supporting reliability professionals. We conclude by proposing a set of research questions to advance the study of ACOs and high-reliability research. © The Author(s) 2016.
CPM Test-Retest Reliability: "Standard" vs "Single Test-Stimulus" Protocols.
Granovsky, Yelena; Miller-Barmak, Adi; Goldstein, Oren; Sprecher, Elliot; Yarnitsky, David
2016-03-01
Assessment of pain inhibitory mechanisms using conditioned pain modulation (CPM) is relevant clinically in prediction of pain and analgesic efficacy. Our objective is to provide necessary estimates of intersession CPM reliability, to enable transformation of the CPM paradigm into a clinical tool. Two cohorts of young healthy subjects (N = 65) participated in two dual-session studies. In Study I, a Bath-Thermode CPM protocol was used, with hot water immersion and contact heat as conditioning- and test-stimuli, respectively, in a classical parallel CPM design introducing test-stimulus first, and then the conditioning- and repeated test-stimuli in parallel. Study II consisted of two CPM protocols: 1) Two-Thermodes, one for each of the stimuli, in the same parallel design as above, and 2) single test-stimulus (STS) protocol with a single administration of a contact heat test-stimulus, partially overlapped in time by a remote shorter contact heat as conditioning stimulus. Test-retest reliability was assessed within 3-7 days. The STS-CPM had superior reliability intraclass correlation (ICC 2 ,: 1 = 0.59) over Bath-Thermode (ICC 2 ,: 1 = 0.34) or Two-Thermodes (ICC 2 ,: 1 = 0.21) protocols. The hand immersion conditioning pain had higher reliability than thermode pain (ICC 2 ,: 1 = 0.76 vs ICC 2 ,: 1 = 0.16). Conditioned test-stimulus pain scores were of good (ICC 2 ,: 1 = 0.62) or fair (ICC 2 ,: 1 = 0.43) reliability for the Bath-Thermode and the STS, respectively, but not for the Two-Thermodes protocol (ICC 2 ,: 1 = 0.20). The newly developed STS-CPM paradigm was more reliable than other CPM protocols tested here, and should be further investigated for its clinical relevance. It appears that large contact size of the conditioning-stimulus and use of single rather than dual test-stimulus pain contribute to augmentation of CPM reliability. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Bisi-Balogun, Adebisi; Rector, Michael
2017-09-01
We sought to develop a standardized protocol for ultrasound (US) measurements of plantar fascia (PF) width and cross-sectional area (CSA), which may serve as additional outcome variables during US examinations of both healthy asymptomatic PF and in plantar fasciopathy and determine its interrater and intrarater reliability. Ten healthy individuals (20 feet) were enrolled. Participants were assessed twice by two raters each to determine intrarater and interrater reliability. For each foot, three transverse scans of the central bundle of the PF were taken at its insertion at the medial calcaneal tubercle, identified in real time on the plantar surface of the foot, using a fine wire technique. Reliability was determined using intraclass correlation coefficients (ICC), standard errors of measurement (SEM), and limits of agreement (LOA) expressed as percentages of the mean. Reliability of PF width and CSA measurements was determined using PF width and CSA measurements from one sonogram measured once and the mean of three measurements from three sonograms each measured once. Ultrasound measurements of PF width and CSA showed a mean of 18.6 ± 2.0 mm and 69.20 ± 13.6 mm 2 respectively. Intra-reliability within both raters showed an ICC > 0.84 for width and ICC > 0.92 for CSA as well as a SEM% and LOA% < 10% for both width and CSA. Inter-rater reliability showed an ICC of 0.82 for width and 0.87 for CSA as well as a SEM% and LOA% < 10% for width and a SEM% < 10% and LOA% < 20% for CSA. Relative and absolute reliability within and between raters were higher when using the mean of three sonographs compared to one sonograph. Using this novel technique, PF CSA and width may be determined reliably using measurements from one sonogram or the mean of three sonograms. Measurement of PF CSA and width in addition to already established thickness and echogenicity measurements provides additional information on structural properties of the PF for clinicians and researchers in healthy and pathologic PF.
Critically re-evaluating a common technique: Accuracy, reliability, and confirmation bias of EMG.
Narayanaswami, Pushpa; Geisbush, Thomas; Jones, Lyell; Weiss, Michael; Mozaffar, Tahseen; Gronseth, Gary; Rutkove, Seward B
2016-01-19
(1) To assess the diagnostic accuracy of EMG in radiculopathy. (2) To evaluate the intrarater reliability and interrater reliability of EMG in radiculopathy. (3) To assess the presence of confirmation bias in EMG. Three experienced academic electromyographers interpreted 3 compact discs with 20 EMG videos (10 normal, 10 radiculopathy) in a blinded, standardized fashion without information regarding the nature of the study. The EMGs were interpreted 3 times (discs A, B, C) 1 month apart. Clinical information was provided only with disc C. Intrarater reliability was calculated by comparing interpretations in discs A and B, interrater reliability by comparing interpretation between reviewers. Confirmation bias was estimated by the difference in correct interpretations when clinical information was provided. Sensitivity was similar to previous reports (77%, confidence interval [CI] 63%-90%); specificity was 71%, CI 56%-85%. Intrarater reliability was good (κ 0.61, 95% CI 0.41-0.81); interrater reliability was lower (κ 0.53, CI 0.35-0.71). There was no substantial confirmation bias when clinical information was provided (absolute difference in correct responses 2.2%, CI -13.3% to 17.7%); the study lacked precision to exclude moderate confirmation bias. This study supports that (1) serial EMG studies should be performed by the same electromyographer since intrarater reliability is better than interrater reliability; (2) knowledge of clinical information does not bias EMG interpretation substantially; (3) EMG has moderate diagnostic accuracy for radiculopathy with modest specificity and electromyographers should exercise caution interpreting mild abnormalities. This study provides Class III evidence that EMG has moderate diagnostic accuracy and specificity for radiculopathy. © 2015 American Academy of Neurology.
Boyle, Diane K; Jayawardhana, Ananda; Burman, Mary E; Dunton, Nancy E; Staggs, Vincent S; Bergquist-Beringer, Sandra; Gajewski, Byron J
2016-11-01
Composite indices are single measures that combine the strengths of two or more individual measures and provide broader, easy-to-use measures for evaluation of provider performance and comparisons across units and hospitals to support quality improvement. The study objective was to develop a unit-level inpatient composite nursing care quality performance index-the Pressure Ulcer and Fall Rate Quality Composite Index. Two-phase measure development study. 5144 patient care units in 857 United States hospitals participating in the National Database of Nursing Quality Indictors ® during the year 2013. The Pressure Ulcer and Fall Rate Quality Composite Index was developed in two phases. In Phase 1 the formula was generated using a utility function and generalized penalty analysis. Experts with experience in healthcare quality measurement provided the point of indicator equivalence. In Phase 2 initial validity evidence was gathered based on hypothesized relationships between the Pressure Ulcer and Fall Rate Quality Composite Index and other variables using two-level (unit, hospital) hierarchical linear mixed modeling. The Pressure Ulcer and Fall Rate Quality Composite Index=100-PUR-FR, where PUR is pressure ulcer rate and FR is total fall rate. Higher scores indicate better quality. Bland-Altman plots demonstrated agreement between pairs of experts and provided evidence for inter-rater reliability of the formula. The validation process demonstrated that higher registered nurse skill mix, higher percent of registered nurses with a baccalaureate in nursing or higher degree, higher percent of registered nurses with national specialty certification, and lower percent of hours supplied by agency staff were significantly associated with higher Pressure Ulcer and Fall Rate Quality Composite Index scores. Higher percentages of unit patients at risk for a hospital-acquired pressure ulcer and higher unit rates of physical restraint use were not associated with higher Pressure Ulcer and Fall Rate Quality Composite Index scores. The Pressure Ulcer and Fall Rate Quality Composite Index is a step toward providing a more holistic perspective of unit level nursing quality than individual measures and may help nurses nursing administrators obtain a broader view of which patient care units are the higher and lower performers. Further study is needed to examine the usability of the Pressure Ulcer and Fall Rate Quality Composite Index. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Jayawardhana, Ananda; Burman, Mary E.; Dunton, Nancy E.; Staggs, Vincent S.; Bergquist-Beringer, Sandra; Gajewski, Byron J.
2016-01-01
Background Composite indices are single measures that combine the strengths of two or more individual measures and provide broader, easy-to-use measures for evaluation of provider performance and comparisons across units and hospitals to support quality improvement. Objective The study objective was to develop a unit-level inpatient composite nursing care quality performance index – the Pressure Ulcer and Fall Rate Quality Composite Index. Design Two-phase measure development study. Settings 5,144 patient care units in 857 United States hospitals participating in the National Database of Nursing Quality Indictors® during the year 2013. Methods The Pressure Ulcer and Fall Rate Quality Composite Index was developed in two phases. In Phase 1 the formula was generated using a utility function and generalized penalty analysis. Experts with experience in healthcare quality measurement provided the point of indicator equivalence. In Phase 2 initial validity evidence was gathered based on hypothesized relationships between the Pressure Ulcer and Fall Rate Quality Composite Index and other variables using two-level (unit, hospital) hierarchical linear mixed modeling. Results The Pressure Ulcer and Fall Rate Quality Composite Index = 100 − PUR − FR, where PUR is pressure ulcer rate and FR is total fall rate. Higher scores indicate better quality. Bland-Altman plots demonstrated agreement between pairs of experts and provided evidence for inter-rater reliability of the formula. The validation process demonstrated that higher registered nurse skill mix, higher percent of registered nurses with a baccalaureate in nursing or higher degree, higher percent of registered nurses with national specialty certification, and lower percent of hours supplied by agency staff were significantly associated with higher Pressure Ulcer and Fall Rate Quality Composite Index scores. Higher percentages of unit patients at risk for a hospital-acquired pressure ulcer and higher unit rates of physical restraint use were not associated with higher Pressure Ulcer and Fall Rate Quality Composite Index scores. Conclusions The Pressure Ulcer and Fall Rate Quality Composite Index is a step toward providing a more holistic perspective of unit level nursing quality than individual measures and may help nurses nursing administrators obtain a broader view of which patient care units are the higher and lower performers. Further study is needed to examine the usability of the Pressure Ulcer and Fall Rate Quality Composite Index. PMID:27607602
System and method for leveraging human physiological traits to control microprocessor frequency
Shye, Alex; Pan, Yan; Scholbrock, Benjamin; Miller, J. Scott; Memik, Gokhan; Dinda, Peter A; Dick, Robert P
2014-03-25
A system and method for leveraging physiological traits to control microprocessor frequency are disclosed. In some embodiments, the system and method may optimize, for example, a particular processor-based architecture based on, for example, end user satisfaction. In some embodiments, the system and method may determine, for example, whether their users are satisfied to provide higher efficiency, improved reliability, reduced power consumption, increased security, and a better user experience. The system and method may use, for example, biometric input devices to provide information about a user's physiological traits to a computer system. Biometric input devices may include, for example, one or more of the following: an eye tracker, a galvanic skin response sensor, and/or a force sensor.
Uncertainties in obtaining high reliability from stress-strength models
NASA Technical Reports Server (NTRS)
Neal, Donald M.; Matthews, William T.; Vangel, Mark G.
1992-01-01
There has been a recent interest in determining high statistical reliability in risk assessment of aircraft components. The potential consequences are identified of incorrectly assuming a particular statistical distribution for stress or strength data used in obtaining the high reliability values. The computation of the reliability is defined as the probability of the strength being greater than the stress over the range of stress values. This method is often referred to as the stress-strength model. A sensitivity analysis was performed involving a comparison of reliability results in order to evaluate the effects of assuming specific statistical distributions. Both known population distributions, and those that differed slightly from the known, were considered. Results showed substantial differences in reliability estimates even for almost nondetectable differences in the assumed distributions. These differences represent a potential problem in using the stress-strength model for high reliability computations, since in practice it is impossible to ever know the exact (population) distribution. An alternative reliability computation procedure is examined involving determination of a lower bound on the reliability values using extreme value distributions. This procedure reduces the possibility of obtaining nonconservative reliability estimates. Results indicated the method can provide conservative bounds when computing high reliability. An alternative reliability computation procedure is examined involving determination of a lower bound on the reliability values using extreme value distributions. This procedure reduces the possibility of obtaining nonconservative reliability estimates. Results indicated the method can provide conservative bounds when computing high reliability.
The Scorer Reliability of Self-Scored Interest Inventories.
ERIC Educational Resources Information Center
O'Shea, Arthur J.; Harrington, Thomas F.
1980-01-01
Describes the procedures the authors of the System for Career Decision-Making (CDM) followed in establishing client scoring reliability. Authors recommend that manuals of self-scored inventories provide data establishing scorer reliability, that scoring be supervised, and that APGA test standards deal directly with scorer reliability. (Author)
Assessment of different methods to estimate bovine colostrum quality on farm.
Bartens, M-C; Drillich, M; Rychli, K; Iwersen, M; Arnholdt, T; Meyer, L; Klein-Jöbstl, D
2016-09-01
To evaluate two different hydrometers and an optical and a digital Brix refractometer for the assessment of bovine colostrum quality, in terms of accuracy and precision compared with the measurement of IgG concentrations using radial immunodiffusion (RID), and to evaluate the reliability and repeatability of the Brix refractometers. To determine reliability and repeatability, 145 colostrum samples were tested by two independent observers twice, using the optical and digital Brix refractometers. A further 193 colostrum samples from Holstein cows were collected on one commercial dairy farm at first milking and tested with two hydrometers and an optical and digital Brix refractometer. An aliquot of each sample was frozen for RID measurement of IgG concentrations and samples were classified as poor (≤50 g IgG/L) or good (>50 g IgG/L) quality colostrum. Intraclass correlation coefficients (ICC) were used to determine inter- and intra-observer reliability and repeatability. Optimised cut-off values for the four devices were determined using receiver operating characteristics (ROC) analysis with the RID results as the reference. Using these cut-offs, sensitivities and specificities for determining good quality colostrum were calculated. The ICC for inter-observer reliability was 0.98 for the optical Brix refractometer, and for intra-observer repeatability was 0.97 and 0.98 for the optical and the digital Brix refractometers, respectively. For the 193 colostrum samples, 67 (34.7%) had concentrations of IgG ≤50 g/L determined by RID. Optimised cut-off values evaluated by ROC analysis were higher for all devices compared with manufacturer reference or previously published values. Using these values, the sensitivities for the two hydrometers, and the optical and the digital Brix refractometers were 0.73, 0.71, 0.56 and 0.79, respectively; specificities were 0.72, 0.61, 0.90 and 0.69, respectively. The Brix refractometers provided the most accurate assessment of colostrum quality of the devices evaluated, and demonstrated excellent precision in terms of repeatability. To provide optimal health for newborn calves, a sufficient intake of good quality colostrum is essential. The Brix refractometers provide rapid, convenient tools for classification of colostrum quality.
Allen Gomes, Ana; Ruivo Marques, Daniel; Meia-Via, Ana Maria; Meia-Via, Mariana; Tavares, José; Fernandes da Silva, Carlos; Pinto de Azevedo, Maria Helena
2015-04-01
Based on successive samples totaling more than 5000 higher education students, we scrutinized the reliability, structure, initial validity and normative scores of a brief self-report seven-item scale to screen for the continuum of nighttime insomnia complaints/perceived sleep quality, used by our team for more than a decade, henceforth labeled the Basic Scale on Insomnia complaints and Quality of Sleep (BaSIQS). In study/sample 1 (n = 1654), the items were developed based on part of a larger survey on higher education sleep-wake patterns. The test-retest study was conducted in an independent small group (n = 33) with a 2-8 week gap. In study/sample 2 (n = 360), focused mainly on validity, the BaSIQS was completed together with the Pittsburgh Sleep Quality Index (PSQI). In study 3, a large recent sample of students from universities all over the country (n = 2995) answered the BaSIQS items, based on which normative scores were determined, and an additional question on perceived sleep problems in order to further analyze the scale's validity. Regarding reliability, Cronbach alpha coefficients were systematically higher than 0.7, and the test-retest correlation coefficient was greater than 0.8. Structure analyses revealed consistently satisfactory two-factor and single-factor solutions. Concerning validity analyses, BaSIQS scores were significantly correlated with PSQI component scores and overall score (r = 0.652 corresponding to a large association); mean scores were significantly higher in those students classifying themselves as having sleep problems (p < 0.0001, d = 0.99 corresponding to a large effect size). In conclusion, the BaSIQS is very easy to administer, and appears to be a reliable and valid scale in higher education students. It might be a convenient short tool in research and applied settings to rapidly assess sleep quality or screen for insomnia complaints, and it may be easily used in other populations with minor adaptations.
Development of a Kinect Software Tool to Classify Movements during Active Video Gaming.
Rosenberg, Michael; Thornton, Ashleigh L; Lay, Brendan S; Ward, Brodie; Nathan, David; Hunt, Daniel; Braham, Rebecca
2016-01-01
While it has been established that using full body motion to play active video games results in increased levels of energy expenditure, there is little information on the classification of human movement during active video game play in relationship to fundamental movement skills. The aim of this study was to validate software utilising Kinect sensor motion capture technology to recognise fundamental movement skills (FMS), during active video game play. Two human assessors rated jumping and side-stepping and these assessments were compared to the Kinect Action Recognition Tool (KART), to establish a level of agreement and determine the number of movements completed during five minutes of active video game play, for 43 children (m = 12 years 7 months ± 1 year 6 months). During five minutes of active video game play, inter-rater reliability, when examining the two human raters, was found to be higher for the jump (r = 0.94, p < .01) than the sidestep (r = 0.87, p < .01), although both were excellent. Excellent reliability was also found between human raters and the KART system for the jump (r = 0.84, p, .01) and moderate reliability for sidestep (r = 0.6983, p < .01) during game play, demonstrating that both humans and KART had higher agreement for jumps than sidesteps in the game play condition. The results of the study provide confidence that the Kinect sensor can be used to count the number of jumps and sidestep during five minutes of active video game play with a similar level of accuracy as human raters. However, in contrast to humans, the KART system required a fraction of the time to analyse and tabulate the results.
DOE Office of Scientific and Technical Information (OSTI.GOV)
El-Badry, Kareem; Quataert, Eliot; Wetzel, Andrew R.
In low-mass galaxies, stellar feedback can drive gas outflows that generate non-equilibrium fluctuations in the gravitational potential. Using cosmological zoom-in baryonic simulations from the Feedback in Realistic Environments project, we investigate how these fluctuations affect stellar kinematics and the reliability of Jeans dynamical modeling in low-mass galaxies. We find that stellar velocity dispersion and anisotropy profiles fluctuate significantly over the course of galaxies’ starburst cycles. We therefore predict an observable correlation between star formation rate and stellar kinematics: dwarf galaxies with higher recent star formation rates should have systemically higher stellar velocity dispersions. This prediction provides an observational test ofmore » the role of stellar feedback in regulating both stellar and dark-matter densities in dwarf galaxies. We find that Jeans modeling, which treats galaxies as virialized systems in dynamical equilibrium, overestimates a galaxy’s dynamical mass during periods of post-starburst gas outflow and underestimates it during periods of net inflow. Short-timescale potential fluctuations lead to typical errors of ∼20% in dynamical mass estimates, even if full three-dimensional stellar kinematics—including the orbital anisotropy—are known exactly. When orbital anisotropy is not known a priori, typical mass errors arising from non-equilibrium fluctuations in the potential are larger than those arising from the mass-anisotropy degeneracy. However, Jeans modeling alone cannot reliably constrain the orbital anisotropy, and problematically, it often favors anisotropy models that do not reflect the true profile. If galaxies completely lose their gas and cease forming stars, fluctuations in the potential subside, and Jeans modeling becomes much more reliable.« less
ZEMEL, BABETTE S.; CAREY, LISA B.; PAULHAMUS, DONNA R.; STALLINGS, VIRGINIA A.; ITTENBACH, RICHARD F.
2014-01-01
Quantifying dietary behavior is difficult and can be intrusive. Calcium, an essential mineral for skeletal development during childhood, is difficult to assess. Few studies have examined the use of food frequency questionnaires (FFQs) for assessing calcium intake in school-age children. This study evaluated the validity and reliability of the Calcium Counts!© FFQ (CCFFQ) for estimating calcium intake in school children in the US. Healthy children, aged 7–10 years (n = 139) completed the CCFFQ and 7-day weighed food records. A subset of subjects completed a second CCFFQ within 3.6 months. Concurrent validity was determined using Pearson correlations between the CCFFQ and food record estimates of calcium intake, and the relationship between quintiles for the two measures. Predictive validity was determined using generalized linear regression models to explore the effects of age, race, and gender. Inter- and intra-individual variability in calcium intake was high (>300 mg/day). Calcium intake was ~300 mg/day higher by CCFFQ compared to food records. Concurrent validity was moderate (r = 0.61) for the entire cohort and higher for selected subgroups. Predictive validity estimates yielded significant relationships between CCFFQ and food record estimates of calcium intake alone and in the presence of such potential effect modifiers as age group, race, and gender. Test–retest reliability was high (r = 0.74). Although calcium intake estimated by the CCFFQ was greater than that measured by food records, the CCFFQ provides valid and reliable estimates of calcium intake in children. The CCFFQ is especially well-suited as a tool to identify children with low calcium intakes. PMID:19621431
Development of a Kinect Software Tool to Classify Movements during Active Video Gaming
Rosenberg, Michael; Lay, Brendan S.; Ward, Brodie; Nathan, David; Hunt, Daniel; Braham, Rebecca
2016-01-01
While it has been established that using full body motion to play active video games results in increased levels of energy expenditure, there is little information on the classification of human movement during active video game play in relationship to fundamental movement skills. The aim of this study was to validate software utilising Kinect sensor motion capture technology to recognise fundamental movement skills (FMS), during active video game play. Two human assessors rated jumping and side-stepping and these assessments were compared to the Kinect Action Recognition Tool (KART), to establish a level of agreement and determine the number of movements completed during five minutes of active video game play, for 43 children (m = 12 years 7 months ± 1 year 6 months). During five minutes of active video game play, inter-rater reliability, when examining the two human raters, was found to be higher for the jump (r = 0.94, p < .01) than the sidestep (r = 0.87, p < .01), although both were excellent. Excellent reliability was also found between human raters and the KART system for the jump (r = 0.84, p, .01) and moderate reliability for sidestep (r = 0.6983, p < .01) during game play, demonstrating that both humans and KART had higher agreement for jumps than sidesteps in the game play condition. The results of the study provide confidence that the Kinect sensor can be used to count the number of jumps and sidestep during five minutes of active video game play with a similar level of accuracy as human raters. However, in contrast to humans, the KART system required a fraction of the time to analyse and tabulate the results. PMID:27442437
The quest for a general theory of aging and longevity.
Gavrilov, Leonid A; Gavrilova, Natalia S
2003-07-16
Extensive studies of phenomena related to aging have produced many diverse findings, which require a general theoretical framework to be organized into a comprehensive body of knowledge. As demonstrated by the success of evolutionary theories of aging, quite general theoretical considerations can be very useful when applied to research on aging. In this theoretical study, we attempt to gain insight into aging by applying a general theory of systems failure known as reliability theory. Considerations of this theory lead to the following conclusions: (i) Redundancy is a concept of crucial importance for understanding aging, particularly the systemic nature of aging. Systems that are redundant in numbers of irreplaceable elements deteriorate (that is, age) over time, even if they are built of elements that do not themselves age. (ii) An apparent aging rate or expression of aging is higher for systems that have higher levels of redundancy. (iii) Redundancy exhaustion over the life course explains a number of observations about mortality, including mortality convergence at later life (when death rates are becoming relatively similar at advanced ages for different populations of the same species) as well as late-life mortality deceleration, leveling off, and mortality plateaus. (iv) Living organisms apparently contain a high load of initial damage from the early stages of development, and therefore their life span and aging patterns may be sensitive to early-life conditions that determine this initial damage load. Thus, the reliability theory provides a parsimonious explanation for many important aging-related phenomena and suggests a number of interesting testable predictions. We therefore suggest adding the reliability theory to the arsenal of methodological approaches applied to research on aging.
NASA Astrophysics Data System (ADS)
O'Connell, M.; Macknick, J.; Voisin, N.; Fu, T.
2017-12-01
The western US electric grid is highly dependent upon water resources for reliable operation. Hydropower and water-cooled thermoelectric technologies represent 67% of generating capacity in the western region of the US. While water resources provide a significant amount of generation and reliability for the grid, these same resources can represent vulnerabilities during times of drought or low flow conditions. A lack of water affects water-dependent technologies and can result in more expensive generators needing to run in order to meet electric grid demand, resulting in higher electricity prices and a higher cost to operate the grid. A companion study assesses the impact of changes in water availability and air temperatures on power operations by directly derating hydro and thermo-electric generators. In this study we assess the sensitivities and tipping points of water availability compared with higher fuel prices in electricity sector operations. We evaluate the impacts of varying electricity prices by modifying fuel prices for coal and natural gas. We then analyze the difference in simulation results between changes in fuel prices in combination with water availability and air temperature variability. We simulate three fuel price scenarios for a 2010 baseline scenario along with 100 historical and future hydro-climate conditions. We use the PLEXOS electricity production cost model to optimize power system dispatch and cost decisions under each combination of fuel price and water constraint. Some of the metrics evaluated are total production cost, generation type mix, emissions, transmission congestion, and reserve procurement. These metrics give insight to how strained the system is, how much flexibility it still has, and to what extent water resource availability or fuel prices drive changes in the electricity sector operations. This work will provide insights into current electricity operations as well as future cases of increased penetration of variable renewable generation technologies such as wind and solar.
Pestaña-Melero, Francisco Luis; Haff, G Gregory; Rojas, Francisco Javier; Pérez-Castilla, Alejandro; García-Ramos, Amador
2017-12-18
This study aimed to compare the between-session reliability of the load-velocity relationship between (1) linear vs. polynomial regression models, (2) concentric-only vs. eccentric-concentric bench press variants, as well as (3) the within-participants vs. the between-participants variability of the velocity attained at each percentage of the one-repetition maximum (%1RM). The load-velocity relationship of 30 men (age: 21.2±3.8 y; height: 1.78±0.07 m, body mass: 72.3±7.3 kg; bench press 1RM: 78.8±13.2 kg) were evaluated by means of linear and polynomial regression models in the concentric-only and eccentric-concentric bench press variants in a Smith Machine. Two sessions were performed with each bench press variant. The main findings were: (1) first-order-polynomials (CV: 4.39%-4.70%) provided the load-velocity relationship with higher reliability than second-order-polynomials (CV: 4.68%-5.04%); (2) the reliability of the load-velocity relationship did not differ between the concentric-only and eccentric-concentric bench press variants; (3) the within-participants variability of the velocity attained at each %1RM was markedly lower than the between-participants variability. Taken together, these results highlight that, regardless of the bench press variant considered, the individual determination of the load-velocity relationship by a linear regression model could be recommended to monitor and prescribe the relative load in the Smith machine bench press exercise.
An Innovative Excel Application to Improve Exam Reliability in Marketing Courses
ERIC Educational Resources Information Center
Keller, Christopher M.; Kros, John F.
2011-01-01
Measures of survey reliability are commonly addressed in marketing courses. One statistic of reliability is "Cronbach's alpha." This paper presents an application of survey reliability as a reflexive application of multiple-choice exam validation. The application provides an interactive decision support system that incorporates survey item…
REANALYSIS OF F-STATISTIC GRAVITATIONAL-WAVE SEARCHES WITH THE HIGHER CRITICISM STATISTIC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bennett, M. F.; Melatos, A.; Delaigle, A.
2013-04-01
We propose a new method of gravitational-wave detection using a modified form of higher criticism, a statistical technique introduced by Donoho and Jin. Higher criticism is designed to detect a group of sparse, weak sources, none of which are strong enough to be reliably estimated or detected individually. We apply higher criticism as a second-pass method to synthetic F-statistic and C-statistic data for a monochromatic periodic source in a binary system and quantify the improvement relative to the first-pass methods. We find that higher criticism on C-statistic data is more sensitive by {approx}6% than the C-statistic alone under optimal conditionsmore » (i.e., binary orbit known exactly) and the relative advantage increases as the error in the orbital parameters increases. Higher criticism is robust even when the source is not monochromatic (e.g., phase-wandering in an accreting system). Applying higher criticism to a phase-wandering source over multiple time intervals gives a {approx}> 30% increase in detectability with few assumptions about the frequency evolution. By contrast, in all-sky searches for unknown periodic sources, which are dominated by the brightest source, second-pass higher criticism does not provide any benefits over a first-pass search.« less
Bayesian Inference for NASA Probabilistic Risk and Reliability Analysis
NASA Technical Reports Server (NTRS)
Dezfuli, Homayoon; Kelly, Dana; Smith, Curtis; Vedros, Kurt; Galyean, William
2009-01-01
This document, Bayesian Inference for NASA Probabilistic Risk and Reliability Analysis, is intended to provide guidelines for the collection and evaluation of risk and reliability-related data. It is aimed at scientists and engineers familiar with risk and reliability methods and provides a hands-on approach to the investigation and application of a variety of risk and reliability data assessment methods, tools, and techniques. This document provides both: A broad perspective on data analysis collection and evaluation issues. A narrow focus on the methods to implement a comprehensive information repository. The topics addressed herein cover the fundamentals of how data and information are to be used in risk and reliability analysis models and their potential role in decision making. Understanding these topics is essential to attaining a risk informed decision making environment that is being sought by NASA requirements and procedures such as 8000.4 (Agency Risk Management Procedural Requirements), NPR 8705.05 (Probabilistic Risk Assessment Procedures for NASA Programs and Projects), and the System Safety requirements of NPR 8715.3 (NASA General Safety Program Requirements).
NASA Astrophysics Data System (ADS)
Andriushin, A. V.; Dolbikova, N. S.; Kiet, S. V.; Merzlikina, E. I.; Nikitina, I. S.
2017-11-01
The reliability of the main equipment of any power station depends on the correct water chemistry. In order to provide it, it is necessary to monitor the heat carrier quality, which, in its turn, is provided by the chemical monitoring system. Thus, the monitoring system reliability plays an important part in providing reliability of the main equipment. The monitoring system reliability is determined by the reliability and structure of its hardware and software consisting of sensors, controllers, HMI and so on [1,2]. Workers of a power plant dealing with the measuring equipment must be informed promptly about any breakdowns in the monitoring system, in this case they are able to remove the fault quickly. A computer consultant system for personnel maintaining the sensors and other chemical monitoring equipment can help to notice faults quickly and identify their possible causes. Some technical solutions for such a system are considered in the present paper. The experimental results were obtained on the laboratory and experimental workbench representing a physical model of a part of the chemical monitoring system.
Transit Reliability Information Program Participants Guidelines
DOT National Transportation Integrated Search
1981-03-01
The document provides guidelines for participation in the Transit Reliability Information Program (TRIP). TRIP is a government-initiated program designed to assist the transit industry in satisfying its need for transit equipment reliability data. TR...
Yan, Yu-Xiang; Liu, You-Qin; Li, Man; Hu, Pei-Feng; Guo, Ai-Min; Yang, Xing-Hua; Qiu, Jing-Jun; Yang, Shan-Shan; Shen, Jian; Zhang, Li-Ping; Wang, Wei
2009-01-01
Background Suboptimal health status (SHS) is characterized by ambiguous health complaints, general weakness, and lack of vitality, and has become a new public health challenge in China. It is believed to be a subclinical, reversible stage of chronic disease. Studies of intervention and prognosis for SHS are expected to become increasingly important. Consequently, a reliable and valid instrument to assess SHS is essential. We developed and evaluated a questionnaire for measuring SHS in urban Chinese. Methods Focus group discussions and a literature review provided the basis for the development of the questionnaire. Questionnaire validity and reliability were evaluated in a small pilot study and in a larger cross-sectional study of 3000 individuals. Analyses included tests for reliability and internal consistency, exploratory and confirmatory factor analysis, and tests for discriminative ability and convergent validity. Results The final questionnaire included 25 items on SHS (SHSQ-25), and encompassed 5 subscales: fatigue, the cardiovascular system, the digestive tract, the immune system, and mental status. Overall, 2799 of 3000 participants completed the questionnaire (93.3%). Test-retest reliability coefficients of individual items ranged from 0.89 to 0.98. Item-subscale correlations ranged from 0.51 to 0.72, and Cronbach’s α was 0.70 or higher for all subscales. Factor analysis established 5 distinct domains, as conceptualized in our model. One-way ANOVA showed statistically significant differences in scale scores between 3 occupation groups; these included total scores and subscores (P < 0.01). The correlation between the SHS scores and experienced stress was statistically significant (r = 0.57, P < 0.001). Conclusions The SHSQ-25 is a reliable and valid instrument for measuring sub-health status in urban Chinese. PMID:19749497
García-Ramos, Amador; Feriche, Belén; Pérez-Castilla, Alejandro; Padial, Paulino; Jaric, Slobodan
2017-07-01
This study aimed to explore the strength of the force-velocity (F-V) relationship of lower limb muscles and the reliability of its parameters (maximum force [F 0 ], slope [a], maximum velocity [V 0 ], and maximum power [P 0 ]). Twenty-three men were tested in two different jump types (squat and countermovement jump: SJ and CMJ), performed under two different loading conditions (free weight and Smith machine: Free and Smith) with 0, 17, 30, 45, 60, and 75 kg loads. The maximum and averaged values of F and V were obtained for the F-V relationship modelling. All F-V relationships were strong and linear independently whether observed from the averaged across the participants (r ≥ 0.98) or individual data (r = 0.94-0.98), while their parameters were generally highly reliable (F 0 [CV: 4.85%, ICC: 0.87], V 0 [CV: 6.10%, ICC: 0.82], a [CV: 10.5%, ICC: 0.81], and P 0 [CV: 3.5%, ICC: 0.93]). Both the strength of the F-V relationships and the reliability of their parameters were significantly higher for (1) the CMJ over the SJ, (2) the Free over the Smith loading type, and (3) the maximum over the averaged F and V variables. In conclusion, although the F-V relationships obtained from all the jumps tested were linear and generally highly reliable, the less appropriate choice for testing the F-V relationship could be through the averaged F and V data obtained from the SJ performed either in a Free weight or in a Smith machine. Insubstantial differences exist among the other combinations tested.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roach, Mack, E-mail: mroach@radonc.ucsf.edu; Ceron Lizarraga, Tania L.; Lazar, Ann A.
Purpose: The optimal treatment of clinically localized prostate cancer is controversial. Most studies focus on biochemical (PSA) failure when comparing radical prostatectomy (RP) with radiation therapy (RT), but this endpoint has not been validated as predictive of overall survival (OS) or cause-specific survival (CSS). We analyzed the available literature to determine whether reliable conclusions could be made concerning the effectiveness of RP compared with RT with or without androgen deprivation therapy (ADT), assuming current treatment standards. Methods: Articles published between February 29, 2004, and March 1, 2015, that compared OS and CSS after RP or RT with or without ADTmore » were included. Because the GRADE (Grading of Recommendations, Assessment, Development, and Evaluation) system emphasis is on randomized controlled clinical trials, a reliability score (RS) was explored to further understand the issues associated with the study quality of observational studies, including appropriateness of treatment, source of data, clinical characteristics, and comorbidity. Lower RS values indicated lower reliability. Results: Fourteen studies were identified, and 13 were completely evaluable. Thirteen of the 14 studies (93%) were observational studies with low-quality evidence. The median RS was 12 (range, 5-18); the median difference in 10-year OS and CSS favored RP over RT: 10% and 4%, respectively. In studies with a RS ≤12 (average RS 9) the 10-year OS and CSS median differences were 17% and 6%, respectively. For studies with a RS >12 (average RS 15.5), the 10-year OS and CSS median differences were 5.5% and 1%, respectively. Thus, we observed an association between low RS and a higher percentage difference in OS and CSS. Conclusions: Reliable evidence that RP provides a superior CSS to RT with ADT is lacking. The most reliable studies suggest that the differences in 10-year CSS between RP and RT are small, possibly <1%.« less
Goetz, Katja; Hasse, Philipp; Szecsenyi, Joachim; Campbell, Stephen M
2016-04-01
The consideration of organisational aspects, such as shared goals and clear communication, within the health care team is important to ensure good quality care. In primary health care, the instrument Survey of Organizational Attributes for Primary Care (SOAPC) is available to measure organisational attributes of care. However, there is no instrument available for dental care. The aim of the present study was to investigate psychometric properties and test-retest reliability of the version of SOAPC adapted for dental care, namely the Survey of Organizational Attributes in Dental Care (SOADC). The SOADC consists of 21 items in the following four subscales: communication; decision making; stress/chaos; and history of change. Convergent construct validity was measured using the job satisfaction scale. A total of 287 dental-care practices were asked to participate in the validation study. Psychometric properties and test-retest reliability were observed. A total of 43 dental-care practices responded to the survey. At baseline, 178 dental-care staff completed the questionnaire, and 4 weeks later 138 did so. Internal consistency, measured by Cronbach's alpha, was 0.718 or higher in the subscales. The test-retest reliability for each subscale and the overall SOADC score demonstrated good correlations over the 4-week test-retest interval, except for 'history of change'. A strong correlation with the aggregated job-satisfaction scale showed high convergent construct validity of SOADC. The consideration of organisational aspects from the perspective of dental-care teams is important for providing good quality of care. The SOADC is a reliable instrument with good psychometric properties and is suitable for the evaluation of organisational attributes in dental-care practices. © 2015 FDI World Dental Federation.
Bartels, Meike; Cath, Danielle C.; Boomsma, Dorret I.
2008-01-01
The factor structure of the Dutch translation of the Autism-Spectrum Quotient (AQ; a continuous, quantitative measure of autistic traits) was evaluated with confirmatory factor analyses in a large general population and student sample. The criterion validity of the AQ was examined in three matched patient groups (autism spectrum conditions (ASC), social anxiety disorder, and obsessive–compulsive disorder). A two factor model, consisting of a “Social interaction” factor and “Attention to detail” factor could be identified. The internal consistency and test–retest reliability of the AQ were satisfactory. High total AQ and factor scores were specific to ASC patients. Men scored higher than women and science students higher than non-science students. The Dutch translation of the AQ is a reliable instrument to assess autism spectrum conditions. PMID:18302013
Aditya, Kaustav; Sud, U. C.
2018-01-01
Poverty affects many people, but the ramifications and impacts affect all aspects of society. Information about the incidence of poverty is therefore an important parameter of the population for policy analysis and decision making. In order to provide specific, targeted solutions when addressing poverty disadvantage small area statistics are needed. Surveys are typically designed and planned to produce reliable estimates of population characteristics of interest mainly at higher geographic area such as national and state level. Sample sizes are usually not large enough to provide reliable estimates for disaggregated analysis. In many instances estimates are required for areas of the population for which the survey providing the data was unplanned. Then, for areas with small sample sizes, direct survey estimation of population characteristics based only on the data available from the particular area tends to be unreliable. This paper describes an application of small area estimation (SAE) approach to improve the precision of estimates of poverty incidence at district level in the State of Bihar in India by linking data from the Household Consumer Expenditure Survey 2011–12 of NSSO and the Population Census 2011. The results show that the district level estimates generated by SAE method are more precise and representative. In contrast, the direct survey estimates based on survey data alone are less stable. PMID:29879202
Chandra, Hukum; Aditya, Kaustav; Sud, U C
2018-01-01
Poverty affects many people, but the ramifications and impacts affect all aspects of society. Information about the incidence of poverty is therefore an important parameter of the population for policy analysis and decision making. In order to provide specific, targeted solutions when addressing poverty disadvantage small area statistics are needed. Surveys are typically designed and planned to produce reliable estimates of population characteristics of interest mainly at higher geographic area such as national and state level. Sample sizes are usually not large enough to provide reliable estimates for disaggregated analysis. In many instances estimates are required for areas of the population for which the survey providing the data was unplanned. Then, for areas with small sample sizes, direct survey estimation of population characteristics based only on the data available from the particular area tends to be unreliable. This paper describes an application of small area estimation (SAE) approach to improve the precision of estimates of poverty incidence at district level in the State of Bihar in India by linking data from the Household Consumer Expenditure Survey 2011-12 of NSSO and the Population Census 2011. The results show that the district level estimates generated by SAE method are more precise and representative. In contrast, the direct survey estimates based on survey data alone are less stable.
Identifying service quality strengths and weaknesses using SERVQUAL: a study of dental services.
Kaldenberg, D; Becker, B W; Browne, B A; Browne, W G
1997-01-01
The goal of this study was to examine responses among dental patients to the most recent version of SERVQUAL, and to evaluate that instrument as a tool for measuring satisfaction in a dental practice. Items on the reliability and responsiveness dimensions produced the lowest satisfaction ratings, while improvements in providing services as promised and instilling confidence have the greatest potential for producing higher satisfaction among patients. Finally, using open-ended questions, we identified a number of patient events or experiences which caused either high or low scores on individual SERVQUAL items.
Makarov, I Iu; Raĭzberg, S A
2012-01-01
The data available from the forensic medical practice do not allow the comprehensive, objective, and reliable assessment of injuries to the human body and damages to the clothes inflicted by the shots from a 9 millimeter (.357) or higher-caliber pneumatic rifle equipped with the pre-charge pneumatic system. The use of bullets of specific structure and configuration for such weapons accounts for their marked influence on the morphological features and the extent of the resulting wounds. These peculiarities provide a basis for the objective differentiation between their injurious effects.
A measure of smoking abstinence-related motivational engagement: Development and initial validation
Heckman, Bryan W.; Ditre, Joseph W.; Brandon, Thomas H.
2010-01-01
Introduction: Although a great deal of research has focused on measuring motivation and readiness to quit smoking, little research has assessed gross motivational changes after a smoker has made an attempt to quit smoking. Unlike previous single-item global measures of motivation to remain abstinent, we developed the abstinence-related motivational engagement (ARME) scale to evaluate the degree to which abstinence motivation is reflected by an ex-smoker’s daily experience in areas that include cognitive effort, priority, vigilance, and excitement. The aim of this study was to collect reliability and initial construct validity data on this new measure. Methods: Participants were 199 ex-smokers recruited from the community and smoking cessation Web sites. Participants completed online measures including a global motivation measure, the ARME scale, demographic questionnaire, and a measure of cessation self-efficacy. Results: The 16-item ARME questionnaire demonstrated high internal consistency reliability (α = .89). Analyses provided support for convergent, discriminant, and construct validity of the scale. ARME demonstrated the predicted correlation with a traditional measure of global cessation motivation, yet, also as predicted, only the ARME was negatively associated with length of abstinence. Moreover, as hypothesized, ex-smokers engaged in the quitting process via ongoing smoking Web site participation showed higher ARME scores than a comparison community sample. A five-item short form demonstrated similar psychometric properties. Discussion: This study provided initial support for the ARME construct and offers two versions of a reliable instrument for assessing this construct. Future research will examine the ARME as a predictor of cessation outcome and a potential target for relapse prevention. PMID:20190004
A measure of smoking abstinence-related motivational engagement: development and initial validation.
Simmons, Vani N; Heckman, Bryan W; Ditre, Joseph W; Brandon, Thomas H
2010-04-01
Although a great deal of research has focused on measuring motivation and readiness to quit smoking, little research has assessed gross motivational changes after a smoker has made an attempt to quit smoking. Unlike previous single-item global measures of motivation to remain abstinent, we developed the abstinence-related motivational engagement (ARME) scale to evaluate the degree to which abstinence motivation is reflected by an ex-smoker's daily experience in areas that include cognitive effort, priority, vigilance, and excitement. The aim of this study was to collect reliability and initial construct validity data on this new measure. Participants were 199 ex-smokers recruited from the community and smoking cessation Web sites. Participants completed online measures including a global motivation measure, the ARME scale, demographic questionnaire, and a measure of cessation self-efficacy. The 16-item ARME questionnaire demonstrated high internal consistency reliability (alpha = .89). Analyses provided support for convergent, discriminant, and construct validity of the scale. ARME demonstrated the predicted correlation with a traditional measure of global cessation motivation, yet, also as predicted, only the ARME was negatively associated with length of abstinence. Moreover, as hypothesized, ex-smokers engaged in the quitting process via ongoing smoking Web site participation showed higher ARME scores than a comparison community sample. A five-item short form demonstrated similar psychometric properties. This study provided initial support for the ARME construct and offers two versions of a reliable instrument for assessing this construct. Future research will examine the ARME as a predictor of cessation outcome and a potential target for relapse prevention.
Reliable intraocular pressure measurement using automated radio-wave telemetry.
Paschalis, Eleftherios I; Cade, Fabiano; Melki, Samir; Pasquale, Louis R; Dohlman, Claes H; Ciolino, Joseph B
2014-01-01
To present an autonomous intraocular pressure (IOP) measurement technique using a wireless implantable transducer (WIT) and a motion sensor. The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS) comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline) IOP. On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg) and mean vehicle IOP (13.27±2.1 mmHg) (P=0.45), suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001), and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001). Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001). Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute), during which the IOP is not expected to change. IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results.
Maïano, Christophe; Bégarie, Jérôme; Morin, Alexandre J S; Garbarino, Jean-Marie; Ninot, Grégory
2010-01-01
The purpose of this study was to test the reliability (i.e. internal consistency and test-retest reliability) and construct validity (i.e. content validity, factor validity, measurement invariance, and latent mean invariance) of the Nutrition and Activity Knowledge Scale (NAKS) in a sample of French adolescents with mild to moderate Intellectual Disability (ID). A total sample of 260 adolescents (144 boys and 116 girls), aged between 12 and 18 years old, with mild to moderate ID was involved in two studies. In the first study, analysis of items' content reveals that many words from the original version were not understood or induced confusion. These items were reworded and simplified while retaining their original meaning. In the second study, results provided support for: (i) the factor validity and reliability of a 15-item French version of the NAKS; (ii) the measurement invariance of the resulting NAKS across genders and ID levels; (iii) the partial measurement invariance of the resulting NAKS across age groups and type of school placement. In addition, the latent means of the 15-item French version of the NAKS proved to be invariant across gender, age categories, and ID levels, but to vary across type of school placement (with adolescents schooled in self-contained classes from regular schools presenting higher levels of NAK than adolescents placed in specialized establishments). The present results thus provide preliminary evidence regarding the construct validity of a 15-item French version of the NAKS in a sample of adolescents with ID.
Technical information report: Plasma melter operation, reliability, and maintenance analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hendrickson, D.W.
1995-03-14
This document provides a technical report of operability, reliability, and maintenance of a plasma melter for low-level waste vitrification, in support of the Hanford Tank Waste Remediation System (TWRS) Low-Level Waste (LLW) Vitrification Program. A process description is provided that minimizes maintenance and downtime and includes material and energy balances, equipment sizes and arrangement, startup/operation/maintence/shutdown cycle descriptions, and basis for scale-up to a 200 metric ton/day production facility. Operational requirements are provided including utilities, feeds, labor, and maintenance. Equipment reliability estimates and maintenance requirements are provided which includes a list of failure modes, responses, and consequences.
Gilkison, C R; Fenton, M V; Lester, J W
1992-05-01
This study was designed to establish the reliability of a health history questionnaire used as a screening tool for incoming university students. The authors used a test-retest design, with a test interval of 6 months, on a sample of medical and nursing students. The analysis focused on overall reliability of the questionnaire and reproducibility of specific items, based on question format. Questionnaire items of specific interest were those with dichotomous yes/no response options versus open-ended format questions, those using the words frequently or recently, or those that asked multiple questions. Demographic characteristics of the subjects were considered in the evaluation of reliability. Overall reliability of the questionnaire (93.6%) was above the anticipated level of 90%, and subject sex or program of study did not show any significant differences in reproducibility of responses. Although wording of questions did not affect item reliability, dichotomous format questions demonstrated a higher degree of reliability (96.4%) than the overall reliability of the questionnaire. Recommendations for enhancing the reliability of the questionnaire are based on item analysis and information gathered from interviews with subjects.
Kaminer, Y; Blitz, C; Burleson, J A; Kadden, R M; Rounsaville, B J
1998-07-01
The state of the art for treatment efficacy studies now requires manual guided treatments and tests of therapist adherence. This report provides findings regarding adherence assessment of therapists participating in an investigation of treatment matching in adolescent substance abusers. The Group Sessions Rating Scale (GSRS), a group-therapy process measure, was studied to determine its appropriateness for assessing group treatment of adolescents with a) substance use disorders (SUD), b) interrater reliability, c) internal consistency, and d) ability to discriminate the active ingredients of cognitive-behavioral therapy (CBT) from interactional therapy (IT). Interrater reliabilities were moderate to high, with those for CBT generally higher than those for IT. Internal consistency of CBT items was moderate, whereas those of IT were moderately high. Discriminability between the two treatment modalities was high. The frequency of active ingredients was generally therapy-specific: high for the relevant and low for the nonrelevant therapeutic modality items. The GSRS was found to be effective in the measurement of treatment process in adolescents with SUD.
[German version of the math anxiety questionnaire (FRA) for 6- to 9-year-old children].
Krinzinger, Helga; Kaufmann, Liane; Dowker, Ann; Thomas, Gemma; Graf, Martina; Nuerk, Hans-Christoph; Willmes, Klaus
2007-09-01
Is the FRA a reliable and valid instrument? Are there any gender differences concerning math anxiety? Are there any developmental changes in this regard in the course of the early grades? Together with the dyscalculia test TEDI-MATH, the FRA was presented to a total of 450 children from the first to the third grade of primary school (at least 40 girls and 40 boys per semester). The total scale has an internal consistency (Cronbach's alpha) between 0.83 and 0.91. Correlations between arithmetic skills and the FRA scales were mostly significant. The significantly higher negative scores for girls were taken into account by providing standard scores corrected for gender. No systematic developmental changes could be observed. The FRA is the first German math anxiety questionnaire for primary school children. High reliability, standard scores corrected for gender, and economic handling make it an instrument well suited for use in clinical settings (e.g., dyscalculia diagnostics and intervention).
Hodge, Lauren M; Turner, Karen M T; Sanders, Matthew R; Filus, Ania
2017-07-01
An evaluation measure of enablers and inhibitors to sustained evidence-based program (EBP) implementation may provide a useful tool to enhance organizations' capacity. This paper outlines preliminary validation of such a measure. An expert informant and consumer feedback approach was used to tailor constructs from two existing measures assessing key domains associated with sustained implementation. Validity and reliability were evaluated for an inventory composed of five subscales: Program benefits, Program burden, Workplace support, Workplace cohesion, and Leadership style. Exploratory and confirmatory factor analysis with a sample of 593 Triple P-Positive Parenting Program-practitioners led to a 28-item scale with good reliability and good convergent, discriminant, and predictive validity. Practitioners sustaining implementation at least 3 years post-training were more likely to have supervision/peer support, reported higher levels of program benefit, workplace support, and positive leadership style, and lower program burden compared to practitioners who were non-sustainers.
[What is parents' and medical health care specialists knowledge about vaccinations?].
Tarczoń, Izabela; Domaradzka, Ewa; Czajka, Hanna
2009-01-01
The aim of the study was to become familiar with parents' and Medical Health Care specialists knowledge and attitude towards vaccinations. The influence of information, provided to patients from various sources, on general opinion about immunization and its coverage within the last year were evaluated. Analysis of questionnaires about vaccinations performed among 151 parents and 180 Medical Health Care specialists. Medical Health Care specialists knowledge was considerably higher in comparison to questioned parents. Surprisingly enough, only approximately 90% of Medical Health Care workers knew about prophylaxis of Hib infections. A doctor is the main and the most reliable source of information for parents. Significant impact on parents' attitude to vaccinations is made not only by campaigns promoting vaccinations, but also by widespread opinions about their harmfulness. The doctor is the major source of reliable information about vaccinations for parents. Therefore, there is the need of continuous improvement of Medical Health Care specialists knowledge, but also the ability of successfully communicating it to parents.
Nuclear reactions from lattice QCD
Briceño, Raúl A.; Davoudi, Zohreh; Luu, Thomas C.
2015-01-13
In this study, one of the overarching goals of nuclear physics is to rigorously compute properties of hadronic systems directly from the fundamental theory of strong interactions, Quantum Chromodynamics (QCD). In particular, the hope is to perform reliable calculations of nuclear reactions which will impact our understanding of environments that occur during big bang nucleosynthesis, the evolution of stars and supernovae, and within nuclear reactors and high energy/density facilities. Such calculations, being truly ab initio, would include all two-nucleon and three- nucleon (and higher) interactions in a consistent manner. Currently, lattice QCD provides the only reliable option for performing calculationsmore » of some of the low-energy hadronic observables. With the aim of bridging the gap between lattice QCD and nuclear many-body physics, the Institute for Nuclear Theory held a workshop on Nuclear Reactions from Lattice QCD on March 2013. In this review article, we report on the topics discussed in this workshop and the path planned to move forward in the upcoming years.« less
Llorens, Esther; Saaltink, Maarten W; Poch, Manel; García, Joan
2011-01-01
The performance and reliability of the CWM1-RETRASO model for simulating processes in horizontal subsurface flow constructed wetlands (HSSF CWs) and the relative contribution of different microbial reactions to organic matter (COD) removal in a HSSF CW treating urban wastewater were evaluated. Various different approaches with diverse influent configurations were simulated. According to the simulations, anaerobic processes were more widespread in the simulated wetland and contributed to a higher COD removal rate [72-79%] than anoxic [0-1%] and aerobic reactions [20-27%] did. In all the cases tested, the reaction that most contributed to COD removal was methanogenesis [58-73%]. All results provided by the model were in consonance with literature and experimental field observations, suggesting a good performance and reliability of CWM1-RETRASO. According to the good simulation predictions, CWM1-RETRASO is the first mechanistic model able to successfully simulate the processes described by the CWM1 model in HSSF CWs. Copyright © 2010 Elsevier Ltd. All rights reserved.
Reliable communication in the presence of failures
NASA Technical Reports Server (NTRS)
Birman, Kenneth P.; Joseph, Thomas A.
1987-01-01
The design and correctness of a communication facility for a distributed computer system are reported on. The facility provides support for fault-tolerant process groups in the form of a family of reliable multicast protocols that can be used in both local- and wide-area networks. These protocols attain high levels of concurrency, while respecting application-specific delivery ordering constraints, and have varying cost and performance that depend on the degree of ordering desired. In particular, a protocol that enforces causal delivery orderings is introduced and shown to be a valuable alternative to conventional asynchronous communication protocols. The facility also ensures that the processes belonging to a fault-tolerant process group will observe consistant orderings of events affecting the group as a whole, including process failures, recoveries, migration, and dynamic changes to group properties like member rankings. A review of several uses for the protocols is the ISIS system, which supports fault-tolerant resilient objects and bulletin boards, illustrates the significant simplification of higher level algorithms made possible by our approach.
A Reliable, Feasible Method to Observe Neighborhoods at High Spatial Resolution
Kepper, Maura M.; Sothern, Melinda S.; Theall, Katherine P.; Griffiths, Lauren A.; Scribner, Richard; Tseng, Tung-Sung; Schaettle, Paul; Cwik, Jessica M.; Felker-Kantor, Erica; Broyles, Stephanie T.
2016-01-01
Introduction Systematic social observation (SSO) methods traditionally measure neighborhoods at street level and have been performed reliably using virtual applications to increase feasibility. Research indicates that collection at even higher spatial resolution may better elucidate the health impact of neighborhood factors, but whether virtual applications can reliably capture social determinants of health at the smallest geographic resolution (parcel level) remains uncertain. This paper presents a novel, parcel-level SSO methodology and assesses whether this new method can be collected reliably using Google Street View and is feasible. Methods Multiple raters (N=5) observed 42 neighborhoods. In 2016, inter-rater reliability (observed agreement and kappa coefficient) was compared for four SSO methods: (1) street-level in person; (2) street-level virtual; (3) parcel-level in person; and (4) parcel-level virtual. Intra-rater reliability (observed agreement and kappa coefficient) was calculated to determine whether parcel-level methods produce results comparable to traditional street-level observation. Results Substantial levels of inter-rater agreement were documented across all four methods; all methods had >70% of items with at least substantial agreement. Only physical decay showed higher levels of agreement (83% of items with >75% agreement) for direct versus virtual rating source. Intra-rater agreement comparing street- versus parcel-level methods resulted in observed agreement >75% for all but one item (90%). Conclusions Results support the use of Google Street View as a reliable, feasible tool for performing SSO at the smallest geographic resolution. Validation of a new parcel-level method collected virtually may improve the assessment of social determinants contributing to disparities in health behaviors and outcomes. PMID:27989289
Chang, Jasper O; Levy, Susan S; Seay, Seth W; Goble, Daniel J
2014-05-01
Recent guidelines advocate sports medicine professionals to use balance tests to assess sensorimotor status in the management of concussions. The present study sought to determine whether a low-cost balance board could provide a valid, reliable, and objective means of performing this balance testing. Criterion validity testing relative to a gold standard and 7 day test-retest reliability. University biomechanics laboratory. Thirty healthy young adults. Balance ability was assessed on 2 days separated by 1 week using (1) a gold standard measure (ie, scientific grade force plate), (2) a low-cost Nintendo Wii Balance Board (WBB), and (3) the Balance Error Scoring System (BESS). Validity of the WBB center of pressure path length and BESS scores were determined relative to the force plate data. Test-retest reliability was established based on intraclass correlation coefficients. Composite scores for the WBB had excellent validity (r = 0.99) and test-retest reliability (R = 0.88). Both the validity (r = 0.10-0.52) and test-retest reliability (r = 0.61-0.78) were lower for the BESS. These findings demonstrate that a low-cost balance board can provide improved balance testing accuracy/reliability compared with the BESS. This approach provides a potentially more valid/reliable, yet affordable, means of assessing sports-related concussion compared with current methods.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, Valerie A.; Ogilvie, Alistair B.
2012-01-01
This report addresses the general data requirements for reliability analysis of fielded wind turbines and other wind plant equipment. The report provides a rationale for why this data should be collected, a list of the data needed to support reliability and availability analysis, and specific data recommendations for a Computerized Maintenance Management System (CMMS) to support automated analysis. This data collection recommendations report was written by Sandia National Laboratories to address the general data requirements for reliability analysis of operating wind turbines. This report is intended to help develop a basic understanding of the data needed for reliability analysis frommore » a Computerized Maintenance Management System (CMMS) and other data systems. The report provides a rationale for why this data should be collected, a list of the data needed to support reliability and availability analysis, and specific recommendations for a CMMS to support automated analysis. Though written for reliability analysis of wind turbines, much of the information is applicable to a wider variety of equipment and analysis and reporting needs. The 'Motivation' section of this report provides a rationale for collecting and analyzing field data for reliability analysis. The benefits of this type of effort can include increased energy delivered, decreased operating costs, enhanced preventive maintenance schedules, solutions to issues with the largest payback, and identification of early failure indicators.« less
Baxter, Suzanne D.; Smith, Albert F.; Hitchcock, David B.; Collins, Kathleen L.; Guinn, Caroline H.; Finney, Christopher J.; Royer, Julie A.; Miller, Patricia H.
2015-01-01
Objective To examine test-retest reliability and internal consistency of a 5-question food insecurity survey used in the National Health and Nutrition Examination Survey. Methods Researchers administered the National Health and Nutrition Examination Survey in the classroom to 92 fourth-grade children (74 African American; 48 girls) in 2 sessions 27–30 days apart in spring, 2011. Each classroom administration lasted 5–10 minutes. Results Test-retest reliability was 0.66 (Kendall tau), which is modest. Internal consistency (Cronbach alpha) was .67 and .70 for respective administrations. Food insecurity scores were related to gender (adjusted P = .05) and academic achievement (adjusted P = .004) but not to socioeconomic status or body mass index percentile (binomial regression). On average, boys reported higher food insecurity than girls. Children with lower academic achievement scores reported higher food insecurity than children with higher academic achievement scores. Conclusions and Implications The National Health and Nutrition Examination 5-question survey may be group administered to assess food insecurity efficiently as reported by individual fourth-grade children. PMID:26363937
Development and practical implications of the Exercise Resourcefulness Inventory.
Fast, Hilary V; Kennett, Deborah J
2015-05-01
To determine the validity and reliability of the Exercise Resourcefulness Inventory (ERI) designed to assess the self-regulatory strategies used to promote regular exercise. In Study 1, the inventory's relationship with other established scales in the exercise behavior change field was examined. In Study 2, the test-retest reliability and predictive validity of the ERI was established by having participants from Study 1 complete the inventory a second time. Internal consistency, and convergent, discriminant, and concurrent validity were supported in both studies. The test-retest correlation of the ERI was .80. As well, participants scoring higher on the ERI in Study 1 were more likely to be at a higher stage of change in Study 2, and greater increases in exercise resourcefulness over time were predictive of advancement to higher stages of change. ERI is a reliable and valid measure to assess the self-regulatory strategies used to promote regular exercise. Facilitators may want to tailor exercise programs for individuals scoring lower in resourcefulness to prevent them from relapsing. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Study of turboprop systems reliability and maintenance costs
NASA Technical Reports Server (NTRS)
1978-01-01
The overall reliability and maintenance costs (R&MC's) of past and current turboprop systems were examined. Maintenance cost drivers were found to be scheduled overhaul (40%), lack of modularity particularly in the propeller and reduction gearbox, and lack of inherent durability (reliability) of some parts. Comparisons were made between the 501-D13/54H60 turboprop system and the widely used JT8D turbofan. It was found that the total maintenance cost per flight hour of the turboprop was 75% higher than that of the JT8D turbofan. Part of this difference was due to propeller and gearbox costs being higher than those of the fan and reverser, but most of the difference was in the engine core where the older technology turboprop core maintenance costs were nearly 70 percent higher than for the turbofan. The estimated maintenance cost of both the advanced turboprop and advanced turbofan were less than the JT8D. The conclusion was that an advanced turboprop and an advanced turbofan, using similar cores, will have very competitive maintenance costs per flight hour.
Gao, Xiang; Lin, Huaiying; Revanna, Kashi; Dong, Qunfeng
2017-05-10
Species-level classification for 16S rRNA gene sequences remains a serious challenge for microbiome researchers, because existing taxonomic classification tools for 16S rRNA gene sequences either do not provide species-level classification, or their classification results are unreliable. The unreliable results are due to the limitations in the existing methods which either lack solid probabilistic-based criteria to evaluate the confidence of their taxonomic assignments, or use nucleotide k-mer frequency as the proxy for sequence similarity measurement. We have developed a method that shows significantly improved species-level classification results over existing methods. Our method calculates true sequence similarity between query sequences and database hits using pairwise sequence alignment. Taxonomic classifications are assigned from the species to the phylum levels based on the lowest common ancestors of multiple database hits for each query sequence, and further classification reliabilities are evaluated by bootstrap confidence scores. The novelty of our method is that the contribution of each database hit to the taxonomic assignment of the query sequence is weighted by a Bayesian posterior probability based upon the degree of sequence similarity of the database hit to the query sequence. Our method does not need any training datasets specific for different taxonomic groups. Instead only a reference database is required for aligning to the query sequences, making our method easily applicable for different regions of the 16S rRNA gene or other phylogenetic marker genes. Reliable species-level classification for 16S rRNA or other phylogenetic marker genes is critical for microbiome research. Our software shows significantly higher classification accuracy than the existing tools and we provide probabilistic-based confidence scores to evaluate the reliability of our taxonomic classification assignments based on multiple database matches to query sequences. Despite its higher computational costs, our method is still suitable for analyzing large-scale microbiome datasets for practical purposes. Furthermore, our method can be applied for taxonomic classification of any phylogenetic marker gene sequences. Our software, called BLCA, is freely available at https://github.com/qunfengdong/BLCA .
Transit Reliability Information Program (TRIP) : Final Technical Report
DOT National Transportation Integrated Search
1984-05-01
The Transit Reliability Information Program (TRIP) is a government-initiated program to assist the transit industry in satisfying its need for rail transit car subsystem reliability information. TRIP provided this assistance through the operation of ...
Transit Reliability Information Program (TRIP) Phase I Report
DOT National Transportation Integrated Search
1981-06-01
The Transit Reliability Information Program (TRIP) is a government initiated program to assist the transit industry in satisfying its need for transit reliability information. TRIP provides this assistance through the operation of a national reliabil...
NASA Astrophysics Data System (ADS)
Cauquil, Jean-Marc; Seguineau, Cédric; Vasse, Christophe; Raynal, Gaetan; Benschop, Tonny
2018-05-01
The cooler reliability is a major performance requested by the customers, especially for 24h/24h applications, which are a growing market. Thales has built a reliability policy based on accelerate ageing and tests to establish a robust knowledge on acceleration factors. The current trend seems to prove that the RM2 mean time to failure is now higher than 30,000hr. Even with accelerate ageing; the reliability growth becomes hardly manageable for such large figures. The paper focuses on these figures and comments the robustness of such a method when projections over 30,000hr of MTTF are needed.
Tsai, Alexander C.; Scott, Jennifer A.; Hung, Kristin J.; Zhu, Jennifer Q.; Matthews, Lynn T.; Psaros, Christina; Tomlinson, Mark
2013-01-01
Background A major barrier to improving perinatal mental health in Africa is the lack of locally validated tools for identifying probable cases of perinatal depression or for measuring changes in depression symptom severity. We systematically reviewed the evidence on the reliability and validity of instruments to assess perinatal depression in African settings. Methods and Findings Of 1,027 records identified through searching 7 electronic databases, we reviewed 126 full-text reports. We included 25 unique studies, which were disseminated in 26 journal articles and 1 doctoral dissertation. These enrolled 12,544 women living in nine different North and sub-Saharan African countries. Only three studies (12%) used instruments developed specifically for use in a given cultural setting. Most studies provided evidence of criterion-related validity (20 [80%]) or reliability (15 [60%]), while fewer studies provided evidence of construct validity, content validity, or internal structure. The Edinburgh postnatal depression scale (EPDS), assessed in 16 studies (64%), was the most frequently used instrument in our sample. Ten studies estimated the internal consistency of the EPDS (median estimated coefficient alpha, 0.84; interquartile range, 0.71-0.87). For the 14 studies that estimated sensitivity and specificity for the EPDS, we constructed 2 x 2 tables for each cut-off score. Using a bivariate random-effects model, we estimated a pooled sensitivity of 0.94 (95% confidence interval [CI], 0.68-0.99) and a pooled specificity of 0.77 (95% CI, 0.59-0.88) at a cut-off score of ≥9, with higher cut-off scores yielding greater specificity at the cost of lower sensitivity. Conclusions The EPDS can reliably and validly measure perinatal depression symptom severity or screen for probable postnatal depression in African countries, but more validation studies on other instruments are needed. In addition, more qualitative research is needed to adequately characterize local understandings of perinatal depression-like syndromes in different African contexts. PMID:24340036
Ball, Lauren E; Leveritt, Michael D
2015-12-01
Nutrition is an important aspect of chronic disease prevention and management by primary health professionals, including GPs, dietitians, practice nurses, diabetes educators and exercise professionals. In order to better understand how to improve the delivery of nutrition care, it is important to have valid and reliable tools to measure self-perceived competence. This study aimed to develop a valid, structured, questionnaire that measures the self-perceived competence of primary health professionals to provide nutrition care to patients with chronic disease. The development of the questionnaire was carried out in four stages (1): preparation of scope and structure, through a literature review and consultation with an expert reference group (2); development of questionnaire items, which were refined through feedback from the reference group and 18 primary health professionals (3); investigation of internal consistency and concurrent validity through a pilot study on 118 primary health professionals (4) and investigation of test-retest reliability through a pilot study on 33 primary health professionals who completed the questionnaire twice, 2-3 weeks apart. Stages 1 and 2 resulted in four constructs and 35 questions in the questionnaire. Stage 3 confirmed internal consistency, with Cronbach's α ranging from 0.88 to 0.98 for each construct and 0.98 for all items combined. Dietitians scored significantly higher than speech pathologists (P < 0.05) in each construct, confirming concurrent validity. Stage 4 confirmed test-retest reliability, with correlation coefficients ranging from 0.89 to 0.94 for each construct and 0.95 for all items combined. The NUTrition COMPetence (NUTCOMP) questionnaire is a valid, reliable and suitable tool that can be used to directly inform professional development and identify opportunities to support safe and effective practice. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Liu, Lu; Parkinson, Simon; Gidden, Matthew; Byers, Edward; Satoh, Yusuke; Riahi, Keywan; Forman, Barton
2018-04-01
Surface water reservoirs provide us with reliable water supply, hydropower generation, flood control and recreation services. Yet reservoirs also cause flow fragmentation in rivers and lead to flooding of upstream areas, thereby displacing existing land-use activities and ecosystems. Anticipated population growth and development coupled with climate change in many regions of the globe suggests a critical need to assess the potential for future reservoir capacity to help balance rising water demands with long-term water availability. Here, we assess the potential of large-scale reservoirs to provide reliable surface water yields while also considering environmental flows within 235 of the world’s largest river basins. Maps of existing cropland and habitat conservation zones are integrated with spatially-explicit population and urbanization projections from the Shared Socioeconomic Pathways to identify regions unsuitable for increasing water supply by exploiting new reservoir storage. Results show that even when maximizing the global reservoir storage to its potential limit (∼4.3–4.8 times the current capacity), firm yields would only increase by about 50% over current levels. However, there exist large disparities across different basins. The majority of river basins in North America are found to gain relatively little firm yield by increasing storage capacity, whereas basins in Southeast Asia display greater potential for expansion as well as proportional gains in firm yield under multiple uncertainties. Parts of Europe, the United States and South America show relatively low reliability of maintaining current firm yields under future climate change, whereas most of Asia and higher latitude regions display comparatively high reliability. Findings from this study highlight the importance of incorporating different factors, including human development, land-use activities, and climate change, over a time span of multiple decades and across a range of different scenarios when quantifying available surface water yields and the potential for reservoir expansion.
A Study of E-Readiness Assessment: The Case of Three Universities in Nigeria
ERIC Educational Resources Information Center
Eweni, Samuel O.
2012-01-01
This study investigated the readiness of three higher educational institutions in Nigeria in their attempt to introduce and maintain technology-driven services to students, faculty, and support staff. The prerequisites for participation in the digital, networked economy include the affordable ICT, reliable electric supply, reliable and up-to-date…
Fiscal Year 2005 Performance and Accountability Report
ERIC Educational Resources Information Center
US Department of Education, 2005
2005-01-01
As the Department looks back on FY 2005, it reflects on successes like the national sample of 9-year-olds whose reading scores are higher this year than in any previous assessment year and challenges like those with collecting reliable, valid, and timely data. This report presents complete, reliable information that demonstrates the Department's…
Alcohol Drinking Onset: A Reliability Study
ERIC Educational Resources Information Center
Prause, JoAnn; Dooley, David; Ham-Rowbottom, Kathleen A.; Emptage, Nicholas
2007-01-01
Early alcohol drinking onset (ADO) is associated with adult alcohol misuse, but the accuracy of ADO is unclear. Reliability of self-reported ADO was studied in two panels of the National Longitudinal Survey of Youth. For the Adult sample (n = 6,215), the intraclass correlation coefficient (ICC) was 0.36. Older respondents had higher reliabilities…
Supporting Beacon and Event-Driven Messages in Vehicular Platoons through Token-Based Strategies
Uhlemann, Elisabeth
2018-01-01
Timely and reliable inter-vehicle communications is a critical requirement to support traffic safety applications, such as vehicle platooning. Furthermore, low-delay communications allow the platoon to react quickly to unexpected events. In this scope, having a predictable and highly effective medium access control (MAC) method is of utmost importance. However, the currently available IEEE 802.11p technology is unable to adequately address these challenges. In this paper, we propose a MAC method especially adapted to platoons, able to transmit beacons within the required time constraints, but with a higher reliability level than IEEE 802.11p, while concurrently enabling efficient dissemination of event-driven messages. The protocol circulates the token within the platoon not in a round-robin fashion, but based on beacon data age, i.e., the time that has passed since the previous collection of status information, thereby automatically offering repeated beacon transmission opportunities for increased reliability. In addition, we propose three different methods for supporting event-driven messages co-existing with beacons. Analysis and simulation results in single and multi-hop scenarios showed that, by providing non-competitive channel access and frequent retransmission opportunities, our protocol can offer beacon delivery within one beacon generation interval while fulfilling the requirements on low-delay dissemination of event-driven messages for traffic safety applications. PMID:29570676
Supporting Beacon and Event-Driven Messages in Vehicular Platoons through Token-Based Strategies.
Balador, Ali; Uhlemann, Elisabeth; Calafate, Carlos T; Cano, Juan-Carlos
2018-03-23
Timely and reliable inter-vehicle communications is a critical requirement to support traffic safety applications, such as vehicle platooning. Furthermore, low-delay communications allow the platoon to react quickly to unexpected events. In this scope, having a predictable and highly effective medium access control (MAC) method is of utmost importance. However, the currently available IEEE 802.11p technology is unable to adequately address these challenges. In this paper, we propose a MAC method especially adapted to platoons, able to transmit beacons within the required time constraints, but with a higher reliability level than IEEE 802.11p, while concurrently enabling efficient dissemination of event-driven messages. The protocol circulates the token within the platoon not in a round-robin fashion, but based on beacon data age, i.e., the time that has passed since the previous collection of status information, thereby automatically offering repeated beacon transmission opportunities for increased reliability. In addition, we propose three different methods for supporting event-driven messages co-existing with beacons. Analysis and simulation results in single and multi-hop scenarios showed that, by providing non-competitive channel access and frequent retransmission opportunities, our protocol can offer beacon delivery within one beacon generation interval while fulfilling the requirements on low-delay dissemination of event-driven messages for traffic safety applications.
Leon, Jaime; Medina-Garrido, Elena; Núñez, Juan L.
2017-01-01
Math achievement and engagement declines in secondary education; therefore, educators are faced with the challenge of engaging students to avoid school failure. Within self-determination theory, we address the need to assess comprehensively student perceptions of teaching quality that predict engagement and achievement. In study one we tested, in a sample of 548 high school students, a preliminary version of a scale to assess nine factors: teaching for relevance, acknowledge negative feelings, participation encouragement, controlling language, optimal challenge, focus on the process, class structure, positive feedback, and caring. In the second study, we analyzed the scale’s reliability and validity in a sample of 1555 high school students. The scale showed evidence of reliability, and with regard to criterion validity, at the classroom level, teaching quality was a predictor of behavioral engagement, and higher grades were observed in classes where students, as a whole, displayed more behavioral engagement. At the within level, behavioral engagement was associated with achievement. We not only provide a reliable and valid method to assess teaching quality, but also a method to design interventions, these could be designed based on the scale items to encourage students to persist and display more engagement on school duties, which in turn bolsters student achievement. PMID:28701964
Developing a model for hospital inherent safety assessment: Conceptualization and validation.
Yari, Saeed; Akbari, Hesam; Gholami Fesharaki, Mohammad; Khosravizadeh, Omid; Ghasemi, Mohammad; Barsam, Yalda; Akbari, Hamed
2018-01-01
Paying attention to the safety of hospitals, as the most crucial institute for providing medical and health services wherein a bundle of facilities, equipment, and human resource exist, is of significant importance. The present research aims at developing a model for assessing hospitals' safety based on principles of inherent safety design. Face validity (30 experts), content validity (20 experts), construct validity (268 examples), convergent validity, and divergent validity have been employed to validate the prepared questionnaire; and the items analysis, the Cronbach's alpha test, ICC test (to measure reliability of the test), composite reliability coefficient have been used to measure primary reliability. The relationship between variables and factors has been confirmed at 0.05 significance level by conducting confirmatory factor analysis (CFA) and structural equations modeling (SEM) technique with the use of Smart-PLS. R-square and load factors values, which were higher than 0.67 and 0.300 respectively, indicated the strong fit. Moderation (0.970), simplification (0.959), substitution (0.943), and minimization (0.5008) have had the most weights in determining the inherent safety of hospital respectively. Moderation, simplification, and substitution, among the other dimensions, have more weight on the inherent safety, while minimization has the less weight, which could be due do its definition as to minimize the risk.
Leon, Jaime; Medina-Garrido, Elena; Núñez, Juan L
2017-01-01
Math achievement and engagement declines in secondary education; therefore, educators are faced with the challenge of engaging students to avoid school failure. Within self-determination theory, we address the need to assess comprehensively student perceptions of teaching quality that predict engagement and achievement. In study one we tested, in a sample of 548 high school students, a preliminary version of a scale to assess nine factors: teaching for relevance, acknowledge negative feelings, participation encouragement, controlling language, optimal challenge, focus on the process, class structure, positive feedback, and caring. In the second study, we analyzed the scale's reliability and validity in a sample of 1555 high school students. The scale showed evidence of reliability, and with regard to criterion validity, at the classroom level, teaching quality was a predictor of behavioral engagement, and higher grades were observed in classes where students, as a whole, displayed more behavioral engagement. At the within level, behavioral engagement was associated with achievement. We not only provide a reliable and valid method to assess teaching quality, but also a method to design interventions, these could be designed based on the scale items to encourage students to persist and display more engagement on school duties, which in turn bolsters student achievement.
Kivisalu, Trisha M; Lewey, Jennifer H; Shaffer, Thomas W; Canfield, Merle L
2016-01-01
The Rorschach Performance Assessment System (R-PAS) aims to provide an evidence-based approach to administration, coding, and interpretation of the Rorschach Inkblot Method (RIM). R-PAS analyzes individualized communications given by respondents to each card to code a wide pool of possible variables. Due to the large number of possible codes that can be assigned to these responses, it is important to consider the concordance rates among different assessors. This study investigated interrater reliability for R-PAS protocols. Data were analyzed from a nonpatient convenience sample of 50 participants who were recruited through networking, local marketing, and advertising efforts from January 2013 through October 2014. Blind recoding was used and discrepancies between the initial and blind coders' ratings were analyzed for each variable with SPSS yielding percent agreement and intraclass correlation values. Data for Location, Space, Contents, Synthesis, Vague, Pairs, Form Quality, Populars, Determinants, and Cognitive and Thematic codes are presented. Rates of agreement for 1,168 responses were higher for more simplistic coding (e.g., Location), whereas agreement was lower for more complex codes (e.g., Cognitive and Thematic codes). Overall, concordance rates achieved good to excellent agreement. Results suggest R-PAS is an effective method with high interrater reliability supporting its empirical basis.
Cardamone-Breen, Mairead C.; Jorm, Anthony F.; Lawrence, Katherine A.; Mackinnon, Andrew J.
2017-01-01
Background Despite substantial evidence demonstrating numerous parental risk and protective factors for the development of adolescent depression and anxiety disorders, there is currently no single measure that assesses these parenting factors. To address this gap, we developed the Parenting to Reduce Adolescent Depression and Anxiety Scale (PRADAS) as a criterion-referenced measure of parental concordance with a set of evidence-based parenting guidelines for the prevention of adolescent depression and anxiety disorders. In this paper, we used a sample of Australian parents of adolescents to: (1) validate the PRADAS as a criterion-referenced measure; (2) examine parental concordance with the guidelines in the sample; and (3) examine correlates of parental concordance with the guidelines. Methods Seven hundred eleven parents completed the PRADAS, as well as two established parenting measures, and parent-report measures of adolescent depression and anxiety symptoms. Six hundred sixty adolescent participants (aged 12–15) also completed the symptom measures. Concordance with the guidelines was assessed via nine subscale scores and a total score. Reliability of the scores was assessed with an estimate of the agreement coefficient, as well as 1-month test-retest reliability. Convergent validity was examined via correlations between the scale and two established parenting measures. Results One proposed subscale was removed from the final version of the scale, resulting in a total of eight subscales. Reliability was high for the total score, and acceptable to high for seven of the eight subscales. One-month test-retest reliability was acceptable to high for the total score. Convergent validity was supported by moderate to high correlations with two established measures of parenting. Overall, rates of parental concordance with the guidelines were low in our sample. Higher scores were associated with being female and higher levels of parental education. Greater parental concordance with the guidelines was associated with fewer symptoms of depression and anxiety in adolescent participants. Discussion This initial validation study provides preliminary support for the reliability and validity of the PRADAS. The scale has potential for use in both clinical and research settings. It may be used to identify parents’ strengths and potential targets for intervention, and as an outcome measure in studies of preventive parenting interventions. PMID:28951815
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-19
... Local Resources Needed for Reliability in the California Wholesale Electric Market; Notice of Staff... Flexible and Local Resources Needed for Reliability in the California Wholesale Electric Market July 31... development of a durable, market-based mechanism to provide incentives to insure reliability needs are met...
NASA Technical Reports Server (NTRS)
Sproles, Darrell W.; Bavuso, Salvatore J.
1994-01-01
The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of highly reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed at the outset to be compatible with most computing platforms and operating systems and some programs have been beta tested within the aerospace community for over 8 years. This document is a user's guide for the HiRel graphical postprocessor program HARPO (HARP Output). HARPO reads ASCII files generated by HARP. It provides an interactive plotting capability that can be used to display alternate model data for trade-off analyses. File data can also be imported to other commercial software programs.
Geckili, Onur; Bilhan, Hakan; Cilingir, Altug; Bilmenoglu, Caglar; Ates, Gokcen; Urgun, Aliye Ceren; Bural, Canan
2014-12-01
A comparative ex vivo study was performed to determine electronic percussive test values (PTVs) measured by cabled and wireless electronic percussive testing (EPT) devices and to evaluate the intra- and interobserver reliability of the wireless EPT device. Forty implants were inserted into the vertebrae and forty into the pelvis of a steer, a safe distance apart. The implants were all 4.3 mm wide and 13 mm long, from the same manufacturer. PTV of each implant was measured by four different examiners, using both EPT devices, and compared. Additionally, the intra- and interobserver reliability of the wireless EPT device was evaluated. Statistically significant differences (P <0.05) were observed between PTVs made by the two EPT devices. PTVs measured by the wireless EPT device were significantly higher than the cabled EPT device (P <0.05), indicating lower implant stability. The intraobserver reliability of the wireless EPT device was evaluated as excellent for the measurements in type II bone and good-to-excellent in type IV bone; interobserver reliability was evaluated as fair-to-good in both bone types. The wireless EPT device gives PTVs higher than the cabled EPT device, indicating lower implant stability, and its inter- and intraobserver reliability is good and acceptable.
Lee, James
2009-01-01
The Long-Term Mechanical Circulatory Support (MCS) System Reliability Recommendation was published in the American Society for Artificial Internal Organs (ASAIO) Journal and the Annals of Thoracic Surgery in 1998. At that time, it was stated that the document would be periodically reviewed to assess its timeliness and appropriateness within 5 years. Given the wealth of clinical experience in MCS systems, a new recommendation has been drafted by consensus of a group of representatives from the medical community, academia, industry, and government. The new recommendation describes a reliability test methodology and provides detailed reliability recommendations. In addition, the new recommendation provides additional information and clinical data in appendices that are intended to assist the reliability test engineer in the development of a reliability test that is expected to give improved predictions of clinical reliability compared with past test methods. The appendices are available for download at the ASAIO journal web site at www.asaiojournal.com.
Campbell, Karen; Taylor, Vanessa; Douglas, Sheila
2017-12-12
Embedding online learning within higher education can provide engaging, cost-effective, interactive and flexible education. By evaluating the impact, outcomes and pedagogical influence of online cancer and education, future curricula can be shaped and delivered by higher education providers to better meet learner, health care provider and educational commissioners' requirements for enhanced patient care and service delivery needs. Using the Kirkpatrick's four-level model of educational evaluation, a systematic review of the effectiveness of online cancer education for nurses and allied health professionals was conducted. From 101 articles, 30 papers were included in the review. Educational theory is not always employed. There is an absence of longitudinal studies to examine impact; an absence of reliability and/or validity testing of measures, limited experimental designs taking account of power and few attempts to mitigate bias. There is, however, an emerging innovative use of mobile/spaced learning techniques. Evidence for clinical and educational effectiveness is weak offering insights into experiences and participant perceptions rather than concrete quantitative data and patient-reported outcomes. More pedagogical research is merited to inform effective evaluation of online cancer education, which incorporates and demonstrates a longer-term impact.
Quality Assurance and Transparency Tools. ENQA Workshop Report 15
ERIC Educational Resources Information Center
Costes, Nathalie; Hopbach, Achim; Kekalainen, Helka; van IJperen, Robin; Walsh, Padraig
2010-01-01
The European Association for Quality Assurance in Higher Education (ENQA) realises that there is a steadily growing interest among students and all stakeholders of Higher Education and the public at large in accessing detailed and reliable information on the quality of individual study programmes, faculties and higher education institutions. ENQA…
Software Reliability Issues Concerning Large and Safety Critical Software Systems
NASA Technical Reports Server (NTRS)
Kamel, Khaled; Brown, Barbara
1996-01-01
This research was undertaken to provide NASA with a survey of state-of-the-art techniques using in industrial and academia to provide safe, reliable, and maintainable software to drive large systems. Such systems must match the complexity and strict safety requirements of NASA's shuttle system. In particular, the Launch Processing System (LPS) is being considered for replacement. The LPS is responsible for monitoring and commanding the shuttle during test, repair, and launch phases. NASA built this system in the 1970's using mostly hardware techniques to provide for increased reliability, but it did so often using custom-built equipment, which has not been able to keep up with current technologies. This report surveys the major techniques used in industry and academia to ensure reliability in large and critical computer systems.
Flitter, Marc A; Riesenmy, Kelly Rouse; van Stralen, Daved
2012-01-01
To offer a theoretical explanation for observed physician resistance and rejection of high reliability patient safety initiatives. A grounded theoretical qualitative approach, utilizing the organizational theory of sensemaking, provided the foundation for inductive and deductive reasoning employed to analyze medical staff rejection of two successfully performing high reliability programs at separate hospitals. Physician behaviors resistant to patient-centric high reliability processes were traced to provider-centric physician sensemaking. Research, conducted with the advantage that prospective studies have over the limitations of this retrospective investigation, is needed to evaluate the potential for overcoming physician resistance to innovation implementation, employing strategies based upon these findings and sensemaking theory in general. If hospitals are to emulate high reliability industries that do successfully manage environments of extreme hazard, physicians must be fully integrated into the complex teams required to accomplish this goal. Reforming health care, through high reliability organizing, with its attendant continuous focus on patient-centric processes, offers a distinct alternative to efforts directed primarily at reforming health care insurance. It is by changing how health care is provided that true cost efficiencies can be achieved. Technology and the insights of organizational science present the opportunity of replacing the current emphasis on privileged information with collective tools capable of providing quality and safety in health care. The fictions that have sustained a provider-centric health care system have been challenged. The benefits of patient-centric care should be obtainable.
General Aviation Aircraft Reliability Study
NASA Technical Reports Server (NTRS)
Pettit, Duane; Turnbull, Andrew; Roelant, Henk A. (Technical Monitor)
2001-01-01
This reliability study was performed in order to provide the aviation community with an estimate of Complex General Aviation (GA) Aircraft System reliability. To successfully improve the safety and reliability for the next generation of GA aircraft, a study of current GA aircraft attributes was prudent. This was accomplished by benchmarking the reliability of operational Complex GA Aircraft Systems. Specifically, Complex GA Aircraft System reliability was estimated using data obtained from the logbooks of a random sample of the Complex GA Aircraft population.
Nakano, Masahiko; Yoshikawa, Takeshi; Hirata, So; Seino, Junji; Nakai, Hiromi
2017-11-05
We have implemented a linear-scaling divide-and-conquer (DC)-based higher-order coupled-cluster (CC) and Møller-Plesset perturbation theories (MPPT) as well as their combinations automatically by means of the tensor contraction engine, which is a computerized symbolic algebra system. The DC-based energy expressions of the standard CC and MPPT methods and the CC methods augmented with a perturbation correction were proposed for up to high excitation orders [e.g., CCSDTQ, MP4, and CCSD(2) TQ ]. The numerical assessment for hydrogen halide chains, polyene chains, and first coordination sphere (C1) model of photoactive yellow protein has revealed that the DC-based correlation methods provide reliable correlation energies with significantly less computational cost than that of the conventional implementations. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
An Enhanced Backbone-Assisted Reliable Framework for Wireless Sensor Networks
Tufail, Ali; Khayam, Syed Ali; Raza, Muhammad Taqi; Ali, Amna; Kim, Ki-Hyung
2010-01-01
An extremely reliable source to sink communication is required for most of the contemporary WSN applications especially pertaining to military, healthcare and disaster-recovery. However, due to their intrinsic energy, bandwidth and computational constraints, Wireless Sensor Networks (WSNs) encounter several challenges in reliable source to sink communication. In this paper, we present a novel reliable topology that uses reliable hotlines between sensor gateways to boost the reliability of end-to-end transmissions. This reliable and efficient routing alternative reduces the number of average hops from source to the sink. We prove, with the help of analytical evaluation, that communication using hotlines is considerably more reliable than traditional WSN routing. We use reliability theory to analyze the cost and benefit of adding gateway nodes to a backbone-assisted WSN. However, in hotline assisted routing some scenarios where source and the sink are just a couple of hops away might bring more latency, therefore, we present a Signature Based Routing (SBR) scheme. SBR enables the gateways to make intelligent routing decisions, based upon the derived signature, hence providing lesser end-to-end delay between source to the sink communication. Finally, we evaluate our proposed hotline based topology with the help of a simulation tool and show that the proposed topology provides manifold increase in end-to-end reliability. PMID:22294890
Critically re-evaluating a common technique
Geisbush, Thomas; Jones, Lyell; Weiss, Michael; Mozaffar, Tahseen; Gronseth, Gary; Rutkove, Seward B.
2016-01-01
Objectives: (1) To assess the diagnostic accuracy of EMG in radiculopathy. (2) To evaluate the intrarater reliability and interrater reliability of EMG in radiculopathy. (3) To assess the presence of confirmation bias in EMG. Methods: Three experienced academic electromyographers interpreted 3 compact discs with 20 EMG videos (10 normal, 10 radiculopathy) in a blinded, standardized fashion without information regarding the nature of the study. The EMGs were interpreted 3 times (discs A, B, C) 1 month apart. Clinical information was provided only with disc C. Intrarater reliability was calculated by comparing interpretations in discs A and B, interrater reliability by comparing interpretation between reviewers. Confirmation bias was estimated by the difference in correct interpretations when clinical information was provided. Results: Sensitivity was similar to previous reports (77%, confidence interval [CI] 63%–90%); specificity was 71%, CI 56%–85%. Intrarater reliability was good (κ 0.61, 95% CI 0.41–0.81); interrater reliability was lower (κ 0.53, CI 0.35–0.71). There was no substantial confirmation bias when clinical information was provided (absolute difference in correct responses 2.2%, CI −13.3% to 17.7%); the study lacked precision to exclude moderate confirmation bias. Conclusions: This study supports that (1) serial EMG studies should be performed by the same electromyographer since intrarater reliability is better than interrater reliability; (2) knowledge of clinical information does not bias EMG interpretation substantially; (3) EMG has moderate diagnostic accuracy for radiculopathy with modest specificity and electromyographers should exercise caution interpreting mild abnormalities. Classification of evidence: This study provides Class III evidence that EMG has moderate diagnostic accuracy and specificity for radiculopathy. PMID:26701380
Integrating reliability and maintainability into a concurrent engineering environment
NASA Astrophysics Data System (ADS)
Phillips, Clifton B.; Peterson, Robert R.
1993-02-01
This paper describes the results of a reliability and maintainability study conducted at the University of California, San Diego and supported by private industry. Private industry thought the study was important and provided the university access to innovative tools under cooperative agreement. The current capability of reliability and maintainability tools and how they fit into the design process is investigated. The evolution of design methodologies leading up to today's capability is reviewed for ways to enhance the design process while keeping cost under control. A method for measuring the consequences of reliability and maintainability policy for design configurations in an electronic environment is provided. The interaction of selected modern computer tool sets is described for reliability, maintainability, operations, and other elements of the engineering design process. These tools provide a robust system evaluation capability that brings life cycle performance improvement information to engineers and their managers before systems are deployed, and allow them to monitor and track performance while it is in operation.
Millimeter and Submillimeter Wave Spectroscopy of Higher Energy Conformers of 1,2-PROPANEDIOL
NASA Astrophysics Data System (ADS)
Zakharenko, Olena; Bossa, Jean-Baptiste; Lewen, Frank; Schlemmer, Stephan; Müller, Holger S. P.
2017-06-01
We have performed a study of the millimeter/submillimeter wave spectrum of four higher energy conformers of 1,2-propanediol (continuation of the previous study on the three lowest energy conformers. The present analysis of rotational transitions carried out in the frequency range 38 - 400 GHz represents a significant extension of previous microwave work. The new data were combined with previously-measured microwave transitions and fitted using a Watson's S-reduced Hamiltonian. The final fits were within experimental accuracy, and included spectroscopic parameters up to sixth order of angular momentum, for the ground states of the four higher energy conformers following previously studied ones: g'Ga, gG'g', aGg' and g'Gg. The present analysis provides reliable frequency predictions for astrophysical detection of 1,2-propanediol by radio telescope arrays at millimeter wavelengths. J.-B. Bossa, M.H. Ordu, H.S.P. Müller, F. Lewen, S. Schlemmer, A&A 570 (2014) A12)
Student perception of the impact of mathematics support in higher education
NASA Astrophysics Data System (ADS)
Fhloinn, E. Ní; Fitzmaurice, O.; Bhaird, C. Mac an; O'Sullivan, C.
2014-10-01
Mathematics support in higher education has become increasingly widespread over the past two decades, particularly in the UK, Ireland and Australia. Despite this, reliable evaluation of mathematics support continues to present challenges for those working in this area. One reason is because ideally, properly structured support should function as an integral part of the overall educational experience of the student, in tandem with lectures and tutorials. When this occurs, it makes it difficult to isolate the impact of mathematics support from these other entities. In this paper, the results of a large-scale nationwide survey conducted with first-year service mathematics students in nine higher education institutes in Ireland are considered, exploring students' perceptions of the impact of mathematics support upon their retention, mathematical confidence, examination performance and overall ability to cope with the mathematical demands they face. Students were extremely positive about the effectiveness of mathematics support in all of these areas, providing valuable insights into the value of learning support in mathematics.
Worry experienced during the 2015 Middle East Respiratory Syndrome (MERS) pandemic in Korea
Ro, Jun-Soo; Lee, Jin-Seok; Kang, Sung-Chan; Jung, Hye-Min
2017-01-01
Background Korea failed in its risk communication during the early stage of the Middle East Respiratory Syndrome (MERS) outbreak; consequently, it faced difficulties in managing MERS, while disease-related worry increased. Disease-related worry can help disease prevention and management, but can also have a detrimental effect. This study measured the overall level of disease-related worry during the MERS outbreak period in Korea and the influencing factors and levels of disease-related worry during key outbreak periods. Methods The cross-sectional survey included 1,000 adults who resided in Korea. An ordinal logistic regression was performed for the overall level of MERS-related worry, and influencing factors of worry were analyzed. A reliability test was performed on the levels of MERS-related worry during key outbreak periods. Results The overall level of MERS-related worry was 2.44. Multivariate analysis revealed that women and respondents w very poor subjective health status had higher levels of worry. Respondents with very high stress in daily life had higher levels of worry than those who reported having little stress. The reliability test results on MERS-related worry scores during key outbreak periods showed consistent scores during each period. Conclusion Level of worry increased in cases having higher perceived susceptibility and greater trust in informal information, while initial stage of outbreak was closely associated with that at later stages. These findings suggest the importance of managing the level of worry by providing timely and accurate disease-related information during the initial stage of disease outbreak. PMID:28273131
The Role of Margin in Link Design and Optimization
NASA Technical Reports Server (NTRS)
Cheung, K.
2015-01-01
Link analysis is a system engineering process in the design, development, and operation of communication systems and networks. Link models that are mathematical abstractions representing the useful signal power and the undesirable noise and attenuation effects (including weather effects if the signal path transverses through the atmosphere) that are integrated into the link budget calculation that provides the estimates of signal power and noise power at the receiver. Then the link margin is applied which attempts to counteract the fluctuations of the signal and noise power to ensure reliable data delivery from transmitter to receiver. (Link margin is dictated by the link margin policy or requirements.) A simple link budgeting approach assumes link parameters to be deterministic values typically adopted a rule-of-thumb policy of 3 dB link margin. This policy works for most S- and X-band links due to their insensitivity to weather effects. But for higher frequency links like Ka-band, Ku-band, and optical communication links, it is unclear if a 3 dB link margin would guarantee link closure. Statistical link analysis that adopted the 2-sigma or 3-sigma link margin incorporates link uncertainties in the sigma calculation. (The Deep Space Network (DSN) link margin policies are 2-sigma for downlink and 3-sigma for uplink.) The link reliability can therefore be quantified statistically even for higher frequency links. However in the current statistical link analysis approach, link reliability is only expressed as the likelihood of exceeding the signal-to-noise ratio (SNR) threshold that corresponds to a given bit-error-rate (BER) or frame-error-rate (FER) requirement. The method does not provide the true BER or FER estimate of the link with margin, or the required signalto-noise ratio (SNR) that would meet the BER or FER requirement in the statistical sense. In this paper, we perform in-depth analysis on the relationship between BER/FER requirement, operating SNR, and coding performance curve, in the case when the channel coherence time of link fluctuation is comparable or larger than the time duration of a codeword. We compute the "true" SNR design point that would meet the BER/FER requirement by taking into account the fluctuation of signal power and noise power at the receiver, and the shape of the coding performance curve. This analysis yields a number of valuable insights on the design choices of coding scheme and link margin for the reliable data delivery of a communication system - space and ground. We illustrate the aforementioned analysis using a number of standard NASA error-correcting codes.
Kang, Lana; Hashmi, Sohaib Z; Nguyen, Joseph; Lee, Steve K; Weiland, Andrew J; Mancuso, Carol A
2016-01-01
Although patient expectations associated with major orthopaedic conditions have shown clinically relevant and variable effects on outcomes, expectations associated with thumb carpometacarpal (CMC) arthritis have not been identified, described, or analyzed before, to our knowledge. We asked: (1) Do patients with thumb CMC arthritis express characteristic expectations that are quantifiable and have measurable frequency? (2) Can a survey on expectations developed from patient-derived data quantitate expectations in patients with thumb CMC arthritis? The study was a prospective cohort study. The first phase was a 12-month-period involving interviews of 42 patients with thumb CMC arthritis to define their expectations of treatment. The interview process used techniques and principles of qualitative methodology including open-ended interview questions, unrestricted time, and study size determined by data saturation. Verbatim responses provided content for the draft survey. The second phase was a 12-month period assessing the survey for test-retest reliability with the recruitment of 36 participants who completed the survey twice. The survey was finalized from clinically relevant content, frequency of endorsement, weighted kappa values for concordance of responses, and intraclass coefficient and Cronbach's alpha for interrater reliability and internal consistency. Thirty-two patients volunteered 256 characteristic expectations, which consisted of 21 discrete categories. Expectations with similar concepts were combined by eliminating redundancy while maintaining original terminology. These were reduced to 19 items that comprised a one-page survey. This survey showed high concordance, interrater reliability, and internal consistency, with weighted kappa values between 0.58 and 0.78 (95% CI, 0.39-0.78; p < 0.001); intraclass correlation coefficient of 0.94 (95% CI, 0.94-0.98; p < 0.001), and Cronbach's alpha values of 0.94 and 0.95 (95% CI, 0.91-0.96; p < 0.001). The thumb CMC arthritis expectations survey score is convertible to an overall score between 0 to 100 points calculated on the basis of the number of expectations and the degree of improvement expected, with higher scores indicating higher expectations. Patients with thumb CMC arthritis volunteer a characteristic and quantifiable set of expectations. Using responses recorded verbatim from patient interviews, a clinically relevant, valid, and reliable expectations survey was developed that measures the physical and psychosocial expectations of patients seeking treatment for CMC arthritis. The survey provides a calculable score that can record patients' expectations. Clinical application of this survey includes identification of factors that influence fulfilment of these expectations. Level II, prospective study.
NASA Technical Reports Server (NTRS)
White, Mark
2012-01-01
New space missions will increasingly rely on more advanced technologies because of system requirements for higher performance, particularly in instruments and high-speed processing. Component-level reliability challenges with scaled CMOS in spacecraft systems from a bottom-up perspective have been presented. Fundamental Front-end and Back-end processing reliability issues with more aggressively scaled parts have been discussed. Effective thermal management from system-level to the componentlevel (top-down) is a key element in overall design of reliable systems. Thermal management in space systems must consider a wide range of issues, including thermal loading of many different components, and frequent temperature cycling of some systems. Both perspectives (top-down and bottom-up) play a large role in robust, reliable spacecraft system design.
Reliability of handheld dynamometry in assessment of hip strength in adult male football players.
Fulcher, Mark L; Hanna, Chris M; Raina Elley, C
2010-01-01
The aim of this study was to evaluate the intra- and interrater reliability of handheld dynamometry (HHD) for measuring hip muscle strength in a sample of 30 healthy semi-professional adult male football players. The reliability of HHD had not been assessed in athletes who were likely to be stronger than populations tested previously. Maximal isometric strength of resisted hip flexion and adduction were measured. Mean strength ranged from 51.5 kg for dominant hip flexion to 26.7 kg for hip adduction at 90 degrees of hip flexion. Intrarater reliability intraclass correlation coefficients (ICCs) ranged from 0.70 to 0.89. ICCs for interrater reliability ranged from 0.66 to 0.87. As expected, muscle strength in this group of athletes was significantly higher than that of populations in which HHD reliability has been assessed. Despite this, muscle strength testing of hip flexor and adductor muscles can be performed with good to excellent intra- and interrater reliability in this population. Copyright (c) 2009. Published by Elsevier Ltd.
Measure of Truck Delay and Reliability at the Corridor Level
DOT National Transportation Integrated Search
2018-04-01
Freight transportation provides a significant contribution to our nations economy. A reliable and accessible freight network enables business in the Twin Cities to be more competitive in the Upper Midwest region. Accurate and reliable freight data...
Behar-Cohen, Francine; Baillet, Gilles; de Ayguavives, Tito; Garcia, Paula Ortega; Krutmann, Jean; Peña-García, Pablo; Reme, Charlotte; Wolffsohn, James S
2014-01-01
Ultraviolet (UV) radiation potentially damages the skin, the immune system, and structures of the eye. A useful UV sun protection for the skin has been established. Since a remarkable body of evidence shows an association between UV radiation and damage to structures of the eye, eye protection is important, but a reliable and practical tool to assess and compare the UV-protective properties of lenses has been lacking. Among the general lay public, misconceptions on eye-sun protection have been identified. For example, sun protection is mainly ascribed to sunglasses, but less so to clear lenses. Skin malignancies in the periorbital region are frequent, but usual topical skin protection does not include the lids. Recent research utilized exact dosimetry and demonstrated relevant differences in UV burden to the eye and skin at a given ambient irradiation. Chronic UV effects on the cornea and lens are cumulative, so effective UV protection of the eyes is important for all age groups and should be used systematically. Protection of children's eyes is especially important, because UV transmittance is higher at a very young age, allowing higher levels of UV radiation to reach the crystalline lens and even the retina. Sunglasses as well as clear lenses (plano and prescription) effectively reduce transmittance of UV radiation. However, an important share of the UV burden to the eye is explained by back reflection of radiation from lenses to the eye. UV radiation incident from an angle of 135°-150° behind a lens wearer is reflected from the back side of lenses. The usual antireflective coatings considerably increase reflection of UV radiation. To provide reliable labeling of the protective potential of lenses, an eye-sun protection factor (E-SPF®) has been developed. It integrates UV transmission as well as UV reflectance of lenses. The E-SPF® compares well with established skin-sun protection factors and provides clear messages to eye health care providers and to lay consumers.
[Quality of service provided to heart surgery patients of the Unified Health System-SUS].
Borges, Juliana Bassalobre Carvalho; Carvalho, Sebastião Marcos Ribeiro de; Silva, Marcos Augusto de Moraes
2010-01-01
To evaluate the service quality provided to heart surgery patients during their hospital stay, identifying the patient's expectations and perceptions. To associate service quality with: gender, age and the use of extracorporeal circulation. We studied 82 elective heart surgery patients (52.4% females and 47.6% males), operated by midsternal thoracotomy, age: 31 to 83 years (60.4 +/- 13.2 years); period: March to September 2006. Service quality was evaluated in two instances: the expectations at pre-operative and the perceptions of the service received on the 6th post-operative; through the application of the modified SERVQUAL scale (SERVQUAL-Card). The result was obtained by the difference of the sum of the scores on perception minus those of the expectations, and through statistical analysis. The SERVQUAL-Card scale was statistically validated, showing adequate level of internal consistency. We found a higher frequency of myocardial revascularization 55 (67.0%); first heart surgery 72 (87.8%) and the use of ECC 69 (84.1%). We noticed high mean values for expectations and perceptions with significant results (P<0.05). We observed a significant relationship between the quality of service with: gender, in empathy (P= 0.04) and age, in reliability (P = 0.02). There was no significant association between ECC and quality of service. Service quality was satisfactory. The patient demonstrated a high expectation to hospital medical service. Women present a higher perception of quality in empathy and younger people in reliability. The use of ECC is not related to service quality in this sample. The data obtained in this study suggest that the quality of this health service can be monitored through the periodical application of the SERVQUAL scale.
Townsend, Marilyn S; Shilts, Mical K; Styne, Dennis M; Drake, Christiana; Lanoue, Louise; Woodhouse, Leslie; Allen, Lindsay H
2016-12-01
Young children are not meeting recommendations for vegetable intake. Our objective is to provide evidence of validity and reliability for a pictorial vegetable behavioral assessment for use by federally funded community nutrition programs. Parent/child pairs (n=133) from Head Start and the Special Supplemental Nutrition Program for Women, Infants and Children [WIC] provided parent-administered vegetable tools, three child 24-hour diet recalls, child blood sample and measured heights/weights. The 10-item Focus on Veggies scale, with an alpha of .83 and a stability reliability coefficient of .74, was positively related to vegetables in cup equivalents [p≤.05]; dietary intakes of folate, vitamin C, β-carotene, potassium and magnesium [p≤.05-.01]; and soluble fiber [p≤.001]. The child vegetable scores were related to the parent's mediators [p≤.00001] and vegetable behaviors [p≤.00001]. Children's plasma inflammatory markers were negatively related to the 10 item scale [p≤.05] and are indicators of the child's health status. The positive relationship between the serum carotenoid index and a sub-scale of child vegetable behaviors offered additional support for criterion validity [p≤.05]. Finally, the inverse relationship of BMI-for-age percentile one year post baseline and a sub-scale of child vegetable behaviors supported the predictive validity [p≤.05]. Focus on Veggies, a simple assessment tool, can inform practitioners about the child's health status. A child with a high score, shows a healthful profile with a lower inflammation index, higher carotenoid index, lower BMI and higher vegetable intake. In conclusion, validity of Focus on Veggies has been demonstrated using vegetable cup equivalents and micronutrient intakes, anthropometry and blood biomarkers. Copyright © 2016 Elsevier Ltd. All rights reserved.
Does the Reliability of Reporting in Injury Surveillance Studies Depend on Injury Definition?
Cross, Matthew; Williams, Sean; Kemp, Simon P T; Fuller, Colin; Taylor, Aileen; Brooks, John; Trewartha, Grant; Stokes, Keith
2018-03-01
Choosing an appropriate definition for injury in injury surveillance studies is essential to ensure a balance among reporting reliability, providing an accurate representation of injury risk, and describing the nature of the clinical demand. To provide guidance on the choice of injury definition for injury surveillance studies by comparing within- and between-team variability in injury incidence with >24-hour and >7-day time-loss injury definitions in a large multiteam injury surveillance study. Cohort study (diagnosis); Level of evidence, 2. Injury data were reported for 2248 professional rugby union players from 15 Premiership Rugby clubs over 12 seasons. Within-team percentage coefficient of variation and mean between-team standard deviation (expressed as a percentage coefficient of variation) in injury incidence rates (injuries per 1000 player match hours) were calculated. For both variables, a comparison was made between >24-hour and >7-day injury incidence rates in terms of the magnitude of the observed effects. The overall mean incidence across the population with a >24-hour time-loss injury definition was approximately double the reported incidence with the >7-day definition. There was a 10% higher between-team variation in match injury incidence rates with the >24-hour time-loss definition versus the >7-day definition. There was a likely higher degree of between-team variation in match injury incidence rates with a >24-hour time-loss definition than with a >7-day definition of injury. However, in professional sports settings, it is likely that the benefits of using a more inclusive definition of injury (improved understanding of clinical demand and the appropriate and accurate reporting of injury risk) outweigh the small increase in variation in reporting consistency.
Does the Reliability of Reporting in Injury Surveillance Studies Depend on Injury Definition?
Cross, Matthew; Williams, Sean; Kemp, Simon P.T.; Fuller, Colin; Taylor, Aileen; Brooks, John; Trewartha, Grant; Stokes, Keith
2018-01-01
Background: Choosing an appropriate definition for injury in injury surveillance studies is essential to ensure a balance among reporting reliability, providing an accurate representation of injury risk, and describing the nature of the clinical demand. Purpose: To provide guidance on the choice of injury definition for injury surveillance studies by comparing within- and between-team variability in injury incidence with >24-hour and >7-day time-loss injury definitions in a large multiteam injury surveillance study. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: Injury data were reported for 2248 professional rugby union players from 15 Premiership Rugby clubs over 12 seasons. Within-team percentage coefficient of variation and mean between-team standard deviation (expressed as a percentage coefficient of variation) in injury incidence rates (injuries per 1000 player match hours) were calculated. For both variables, a comparison was made between >24-hour and >7-day injury incidence rates in terms of the magnitude of the observed effects. Results: The overall mean incidence across the population with a >24-hour time-loss injury definition was approximately double the reported incidence with the >7-day definition. There was a 10% higher between-team variation in match injury incidence rates with the >24-hour time-loss definition versus the >7-day definition. Conclusion: There was a likely higher degree of between-team variation in match injury incidence rates with a >24-hour time-loss definition than with a >7-day definition of injury. However, in professional sports settings, it is likely that the benefits of using a more inclusive definition of injury (improved understanding of clinical demand and the appropriate and accurate reporting of injury risk) outweigh the small increase in variation in reporting consistency. PMID:29581994
Testing the woman abuse screening tool to identify intimate partner violence in Indonesia.
Iskandar, Livia; Braun, Kathryn L; Katz, Alan R
2015-04-01
Intimate Partner Violence (IPV) is a global public health problem. IPV prevalence in Indonesia has been estimated to be less than 1%, based on reported cases. It is likely that IPV prevalence is underreported in Indonesia, as it is in many other countries. Screening for IPV has been found to increase IPV identification, but no screening tools are in use in Indonesia. The aim of this study was to test the translated Woman Abuse Screening Tool (WAST) for detecting IPV in Indonesia. The WAST was tested against a diagnostic interview by a trained psychologist on 240 women attending two Primary Health Centers in Jakarta. IPV prevalence and the reliability, sensitivity, and specificity of the WAST were estimated. Prevalence of IPV by diagnostic interview was 36.3%, much higher than published estimates. The most common forms of IPV identified were psychological (85%) and physical abuse (24%). Internal reliability of the WAST was high (α = .801). A WAST score of 13 (out of 24) is the recommended cutoff for identifying IPV, but only 17% of the Indonesian sample scored 13 or higher. Test sensitivity of the WAST with a cutoff score of 13 was only 41.9%, with a specificity of 96.8%. With a cutoff score of 10, the sensitivity improved to 84.9%, while the specificity decreased to 61.0%. Use of the WAST with a cutoff score of 10 provides good sensitivity and reasonable specificity and would provide a much-needed screening tool for use in Indonesia. Although a lower cutoff would yield a greater proportion of false positives, most of the true cases would be identified, increasing the possibility that women experiencing abuse would receive needed assistance. © The Author(s) 2014.
SMN transcript levels in leukocytes of SMA patients determined by absolute real-time PCR
Tiziano, Francesco Danilo; Pinto, Anna Maria; Fiori, Stefania; Lomastro, Rosa; Messina, Sonia; Bruno, Claudio; Pini, Antonella; Pane, Marika; D'Amico, Adele; Ghezzo, Alessandro; Bertini, Enrico; Mercuri, Eugenio; Neri, Giovanni; Brahe, Christina
2010-01-01
Spinal muscular atrophy (SMA) is an autosomal recessive neuromuscular disorder caused by homozygous mutations of the SMN1 gene. Three forms of SMA are recognized (type I–III) on the basis of clinical severity. All patients have at least one or more (usually 2–4) copies of a highly homologous gene (SMN2), which produces insufficient levels of functional SMN protein, because of alternative splicing of exon 7. Recently, evidence has been provided that SMN2 expression can be enhanced by pharmacological treatment. However, no reliable biomarkers are available to test the molecular efficacy of the treatments. At present, the only potential biomarker is the dosage of SMN products in peripheral blood. However, the demonstration that SMN full-length (SMN-fl) transcript levels are reduced in leukocytes of patients compared with controls remains elusive (except for type I). We have developed a novel assay based on absolute real-time PCR, which allows the quantification of SMN1-fl/SMN2-fl transcripts. For the first time, we have shown that SMN-fl levels are reduced in leukocytes of type II–III patients compared with controls. We also found that transcript levels are related to clinical severity as in type III patients SMN2-fl levels are significantly higher compared with type II and directly correlated with functional ability in type II patients and with age of onset in type III patients. Moreover, in haploidentical siblings with discordant phenotype, the less severely affected individuals showed significantly higher transcript levels. Our study shows that SMN2-fl dosage in leukocytes can be considered a reliable biomarker and can provide the rationale for SMN dosage in clinical trials. PMID:19603064
Hickman, Ronald L; Clochesy, John M; Hetland, Breanna; Alaamri, Marym
2017-04-01
There are limited reliable and valid measures of the patient- provider interaction among adults with hypertension. Therefore, the purpose of this report is to describe the construct validity and reliability of the Questionnaire on the Quality of Physician-Patient Interaction (QQPPI), in community-dwelling adults with hypertension. A convenience sample of 109 participants with hypertension was recruited and administered the QQPPI at baseline and 8 weeks later. The exploratory factor analysis established a 12-item, 2-factor structure for the QQPPI was valid in this sample. The modified QQPPI proved to have sufficient internal consistency and test- retest reliability. The modified QQPPI is a valid and reliable measure of the provider-patient interaction, a construct posited to impact self-management, in adults with hypertension.
Psychometric analysis of five measures of spatial ability.
Hogan, Thomas P
2012-02-01
This study analyzed psychometric properties of five measures of spatial ability on 96 young adults, with supplementary analysis for three of the measures on another sample of 71 young adults. Two measures were taken from the widely cited Kit of Factor-Referenced Cognitive Tests and three other measures were taken from a relatively new source originally intended as laboratory demonstrations. Previous research provided limited information on the psychometric properties of the measures. All five measures yielded adequate reliability and loaded on a single factor. Three measures yielded markedly skewed distributions. Two measures showed clear sex differences with men scoring higher but this difference seemed contaminated by a speed factor; three measures did not show a sex difference. Recommendations for use of the measures in future studies are provided.
On-clip high frequency reliability and failure test structures
Snyder, Eric S.; Campbell, David V.
1997-01-01
Self-stressing test structures for realistic high frequency reliability characterizations. An on-chip high frequency oscillator, controlled by DC signals from off-chip, provides a range of high frequency pulses to test structures. The test structures provide information with regard to a variety of reliability failure mechanisms, including hot-carriers, electromigration, and oxide breakdown. The system is normally integrated at the wafer level to predict the failure mechanisms of the production integrated circuits on the same wafer.
Assuring reliability program effectiveness.
NASA Technical Reports Server (NTRS)
Ball, L. W.
1973-01-01
An attempt is made to provide simple identification and description of techniques that have proved to be most useful either in developing a new product or in improving reliability of an established product. The first reliability task is obtaining and organizing parts failure rate data. Other tasks are parts screening, tabulation of general failure rates, preventive maintenance, prediction of new product reliability, and statistical demonstration of achieved reliability. Five principal tasks for improving reliability involve the physics of failure research, derating of internal stresses, control of external stresses, functional redundancy, and failure effects control. A final task is the training and motivation of reliability specialist engineers.
National Student Survey: Are Differences between Universities and Courses Reliable and Meaningful?
ERIC Educational Resources Information Center
Cheng, Jacqueline H. S.; Marsh, Herbert W.
2010-01-01
The National Student Survey (NSS) of course experience satisfaction is sent to final year students of all higher education institutions in England, Northern Ireland, Scotland and Wales (N = 171,290 and 157,342 students in 2005 and 2006) and results are made publicly available. The present investigation assesses the reliability and appropriate use…
NASA Technical Reports Server (NTRS)
1972-01-01
The design is reported of an advanced modular computer system designated the Automatically Reconfigurable Modular Multiprocessor System, which anticipates requirements for higher computing capacity and reliability for future spaceborne computers. Subjects discussed include: an overview of the architecture, mission analysis, synchronous and nonsynchronous scheduling control, reliability, and data transmission.
Evaluating the Level of Degree Programmes in Higher Education: The Case of Nursing
ERIC Educational Resources Information Center
Rexwinkel, Trudy; Haenen, Jacques; Pilot, Albert
2013-01-01
The European Quality Assurance system demands that the degree programme level is represented in terms of quantitative outcomes to be valid and reliable. To meet this need the Educational Level Evaluator (ELE) was devised. This conceptually designed procedure with instrumentation aiming to evaluate the level of a degree validly and reliably still…
ERIC Educational Resources Information Center
Ali, Syed Haris; Carr, Patrick A.; Ruit, Kenneth G.
2016-01-01
Plausible distractors are important for accurate measurement of knowledge via multiple-choice questions (MCQs). This study demonstrates the impact of higher distractor functioning on validity and reliability of scores obtained on MCQs. Freeresponse (FR) and MCQ versions of a neurohistology practice exam were given to four cohorts of Year 1 medical…
ERIC Educational Resources Information Center
Roberts, Lindsay S.; Sharma, Sushma; Hudes, Mark L.; Fleming, Sharon E.
2012-01-01
Background: African-American and Latino children living in neighborhoods with a low-socioeconomic index are more at risk of obesity-associated metabolic disease than their higher socioeconomic index and/or white peers. Currently, consistent and reliable questionnaires to evaluate nutrition and physical activity knowledge in these children are…
Handy, Sara M; Deeds, Jonathan R; Ivanova, Natalia V; Hebert, Paul D N; Hanner, Robert H; Ormos, Andrea; Weigt, Lee A; Moore, Michelle M; Yancy, Haile F
2011-01-01
The U.S. Food and Drug Administration is responsible for ensuring that the nation's food supply is safe and accurately labeled. This task is particularly challenging in the case of seafood where a large variety of species are marketed, most of this commodity is imported, and processed product is difficult to identify using traditional morphological methods. Reliable species identification is critical for both foodborne illness investigations and for prevention of deceptive practices, such as those where species are intentionally mislabeled to circumvent import restrictions or for resale as species of higher value. New methods that allow accurate and rapid species identifications are needed, but any new methods to be used for regulatory compliance must be both standardized and adequately validated. "DNA barcoding" is a process by which species discriminations are achieved through the use of short, standardized gene fragments. For animals, a fragment (655 base pairs starting near the 5' end) of the cytochrome c oxidase subunit 1 mitochondrial gene has been shown to provide reliable species level discrimination in most cases. We provide here a protocol with single-laboratory validation for the generation of DNA barcodes suitable for the identification of seafood products, specifically fish, in a manner that is suitable for FDA regulatory use.
Lee, Hyung-Min; Ghovanloo, Maysam
2014-01-01
In this paper, we present a fully integrated active voltage doubler in CMOS technology using offset-controlled high speed comparators for extending the range of inductive power transmission to implantable microelectronic devices (IMD) and radio-frequency identification (RFID) tags. This active voltage doubler provides considerably higher power conversion efficiency (PCE) and lower dropout voltage compared to its passive counterpart and requires lower input voltage than active rectifiers, leading to reliable and efficient operation with weakly coupled inductive links. The offset-controlled functions in the comparators compensate for turn-on and turn-off delays to not only maximize the forward charging current to the load but also minimize the back current, optimizing PCE in the high frequency (HF) band. We fabricated the active voltage doubler in a 0.5-μm 3M2P std. CMOS process, occupying 0.144 mm2 of chip area. With 1.46 V peak AC input at 13.56 MHz, the active voltage doubler provides 2.4 V DC output across a 1 kΩ load, achieving the highest PCE = 79% ever reported at this frequency. In addition, the built-in start-up circuit ensures a reliable operation at lower voltages. PMID:23853321
Kushnir, Jonathan; Gothelf, Doron; Sadeh, Avi
2015-01-01
Although excessive fears are common in preschool children, validated assessment tools for this age are lacking. Our aim was to modify and provide preliminary evidence of the utility of a preschoolers' fear screening tool, a parent-reported Fear Survey Schedule for Preschool Children (FSS-PC). 109 Israeli preschool children (aged 4-6 years) with chronic night time fears (NF) and 30 healthy children (controls) participated. The FSS-PC analysis included: 1) internal reliability, 2) correlations between FSS-PC scores and Child Behavior Checklist (CBCL) measures, 3) differences between NF and a comparison sample of FSS-PC scores, and 4) FSS-PC sensitivity in detecting change in NF following an intervention for NF. There were low-to-medium positive correlations between the FSS-PC scores and several internalizing scales of the CBCL measures. FSS-PC scores in the NF group were significantly higher than the control children's score. FSS-PC scores had adequate internal reliability and were also sensitive for detecting significant changes in fear levels following behavioral interventions. Unique cultural and environmental circumstances and specific study group. This new version of the FSS-PC may provide clinicians with a novel and useful screening tool for early assessment of fear- and anxiety-related phenomena of preschool children.
Effectiveness of Visual Methods in Information Procedures for Stem Cell Recipients and Donors
Sarıtürk, Çağla; Gereklioğlu, Çiğdem; Korur, Aslı; Asma, Süheyl; Yeral, Mahmut; Solmaz, Soner; Büyükkurt, Nurhilal; Tepebaşı, Songül; Kozanoğlu, İlknur; Boğa, Can; Özdoğu, Hakan
2017-01-01
Objective: Obtaining informed consent from hematopoietic stem cell recipients and donors is a critical step in the transplantation process. Anxiety may affect their understanding of the provided information. However, use of audiovisual methods may facilitate understanding. In this prospective randomized study, we investigated the effectiveness of using an audiovisual method of providing information to patients and donors in combination with the standard model. Materials and Methods: A 10-min informational animation was prepared for this purpose. In total, 82 participants were randomly assigned to two groups: group 1 received the additional audiovisual information and group 2 received standard information. A 20-item questionnaire was administered to participants at the end of the informational session. Results: A reliability test and factor analysis showed that the questionnaire was reliable and valid. For all participants, the mean overall satisfaction score was 184.8±19.8 (maximum possible score of 200). However, for satisfaction with information about written informed consent, group 1 scored significantly higher than group 2 (p=0.039). Satisfaction level was not affected by age, education level, or differences between the physicians conducting the informative session. Conclusion: This study shows that using audiovisual tools may contribute to a better understanding of the informed consent procedure and potential risks of stem cell transplantation. PMID:27476890
Novel laser tissue-soldering technique for dural reconstruction.
Gil, Ziv; Shaham, Amit; Vasilyev, Tamar; Brosh, Tamar; Forer, Boaz; Katzir, Abraham; Fliss, Dan M
2005-07-01
The goal of this study was to use a modified version of the CO2 laser-soldering system to develop a simple and reliable technique for the repair of dural defects after excision of brain tumors. The authors used a CO2 fiber optic laser system that they had developed for heating, monitoring, and controlling tissue temperature in situ and in real time, thereby reducing damage to the brain parenchyma. They adapted the system for dural closure by using free fascial grafts in a porcine model. Measures for estimation of reconstruction quality included visual assessment under magnification and direct measurements of adhesive strength and cerebrospinal fluid leak (CSF) pressure. Reliable soldering was achieved in 54 of 57 experiments, providing a 95% success rate. The average peak adhesive strength was 82 +/- 3 mN/cm2. The measured leak pressure of the fascia-dura mater bond was 66 +/- 5 mm Hg. Conventional suturing performed using Prolene stitches resulted in immediate CSF leakage from areas between the stitches and from the area of the needle hole itself. Fascia-dura mater soldering using the CO2 laser is feasible and may support CSF pressure up to six times higher than normal intracranial pressure. Findings of this study may provide a basis for the development of new tools for dural reconstruction.
Seo, Jeong-Ho; Boedijono, Dimas
2016-01-01
Purpose The aim of this study was to investigate new point-connecting measurements for the hallux valgus angle (HVA) and the first intermetatarsal angle (IMA), which can reflect the degree of subluxation of the first metatarsophalangeal joint (MTPJ). Also, this study attempted to compare the validity of midline measurements and the new point-connecting measurements for the determination of HVA and IMA values. Materials and Methods Sixty feet of hallux valgus patients who underwent surgery between 2007 and 2011 were classified in terms of the severity of HVA, congruency of the first MTPJ, and type of chevron metatarsal osteotomy. On weight-bearing dorsal-plantar radiographs, HVA and IMA values were measured and compared preoperatively and postoperatively using both the conventional and new methods. Results Compared with midline measurements, point-connecting measurements showed higher inter- and intra-observer reliability for preoperative HVA/IMA and similar or higher inter- and intra-observer reliability for postoperative HVA/IMA. Patients who underwent distal chevron metatarsal osteotomy (DCMO) had higher intraclass correlation coefficient for inter- and intra-observer reliability for pre- and post-operative HVA and IMA measured by the point-connecting method compared with the midline method. All differences in the preoperative HVAs and IMAs determined by both the midline method and point-connecting methods were significant between the deviated group and subluxated groups (p=0.001). Conclusion The point-connecting method for measuring HVA and IMA in the subluxated first MTPJ may better reflect the severity of a HV deformity with higher reliability than the midline method, and is more useful in patients with DCMO than in patients with proximal chevron metatarsal osteotomy. PMID:26996576
Boles, Richard E; Burdell, Alexandra; Johnson, Susan L; Gavin, William J; Davies, Patricia L; Bellows, Laura L
2014-09-01
The purpose of this study was to refine and psychometrically test an instrument measuring the home food and activity environment of geographically and economically diverse families of preschool aged children. Caregivers of preschool aged children (n = 83) completed a modified self-report questionnaire. Reliably trained researchers conducted independent observations on 25 randomly selected homes. Agreement statistics were conducted at the item level (154 total items) to determine reliability. Frequency counts were calculated to identify item availability. Results showed Kappa statistics were high (.67-1.00) between independent researchers but varied between researchers and parents resulting in 85 items achieving criterion validity (Kappa >.60). Analyses of reliable items revealed the presence in the home of a high frequency of unhealthy snack foods, high fat milk and low frequency of availability of fruits/vegetables and low fat milk. Fifty-two percent of the homes were arranged with a television in the preschool child's bedroom. Physical Activity devices also were found to have high frequency availability. Families reporting lower education reported higher levels of sugar sweetened beverages and less low-fat dairy (p < .05) compared with higher education families. Low-income families (<$27K per year) reported significantly fewer Physical Activity devices (p < .001) compared with higher income families. Hispanic families reported significantly higher numbers of Sedentary Devices (p < .05) compared with non-Hispanic families. There were no significant differences between demographic comparisons on available fruits/vegetables, meats, whole grains, and regular fat dairy. A modified home food and activity instrument was found to reliably identify foods and activity devices with geographically and economically diverse families. Copyright © 2014 Elsevier Ltd. All rights reserved.
7 CFR 760.405 - Application process.
Code of Federal Regulations, 2011 CFR
2011-01-01
... death documentation is not available, the participant may provide reliable records, in conjunction with verifiable beginning and ending inventory records, as proof of death. Reliable records may include..., pictures, and other similar reliable documents as determined by FSA. (f) Certification of livestock deaths...
NASA Astrophysics Data System (ADS)
Chan, Kwai S.; Enright, Michael P.; Moody, Jonathan; Fitch, Simeon H. K.
2014-01-01
The objective of this investigation was to develop an innovative methodology for life and reliability prediction of hot-section components in advanced turbopropulsion systems. A set of generic microstructure-based time-dependent crack growth (TDCG) models was developed and used to assess the sources of material variability due to microstructure and material parameters such as grain size, activation energy, and crack growth threshold for TDCG. A comparison of model predictions and experimental data obtained in air and in vacuum suggests that oxidation is responsible for higher crack growth rates at high temperatures, low frequencies, and long dwell times, but oxidation can also induce higher crack growth thresholds (Δ K th or K th) under certain conditions. Using the enhanced risk analysis tool and material constants calibrated to IN 718 data, the effect of TDCG on the risk of fracture in turboengine components was demonstrated for a generic rotor design and a realistic mission profile using the DARWIN® probabilistic life-prediction code. The results of this investigation confirmed that TDCG and cycle-dependent crack growth in IN 718 can be treated by a simple summation of the crack increments over a mission. For the temperatures considered, TDCG in IN 718 can be considered as a K-controlled or a diffusion-controlled oxidation-induced degradation process. This methodology provides a pathway for evaluating microstructural effects on multiple damage modes in hot-section components.
NASA Astrophysics Data System (ADS)
Galve, J. P.; Gutiérrez, F.; Remondo, J.; Bonachea, J.; Lucha, P.; Cendrero, A.
2009-10-01
Multiple sinkhole susceptibility models have been generated in three study areas of the Ebro Valley evaporite karst (NE Spain) applying different methods (nearest neighbour distance, sinkhole density, heuristic scoring system and probabilistic analysis) for each sinkhole type separately (cover collapse sinkholes, cover and bedrock collapse sinkholes and cover and bedrock sagging sinkholes). The quantitative and independent evaluation of the predictive capability of the models reveals that: (1) The most reliable susceptibility models are those derived from the nearest neighbour distance and sinkhole density. These models can be generated in a simple and rapid way from detailed geomorphological maps. (2) The reliability of the nearest neighbour distance and density models is conditioned by the degree of clustering of the sinkholes. Consequently, the karst areas in which sinkholes show a higher clustering are a priori more favourable for predicting new occurrences. (3) The predictive capability of the best models obtained in this research is significantly higher (12.5-82.5%) than that of the heuristic sinkhole susceptibility model incorporated into the General Urban Plan for the municipality of Zaragoza. Although the probabilistic approach provides lower quality results than the methods based on sinkhole proximity and density, it helps to identify the most significant factors and select the most effective mitigation strategies and may be applied to model susceptibility in different future scenarios.
Schwartz, Karen T G; Bowling, Amanda A; Dickerson, John F; Lynch, Frances L; Brent, David A; Porta, Giovanna; Iyengar, Satish; Weersing, V Robin
2018-05-24
The current study evaluated the interrater reliability of the Child and Adolescent Services Assessment (CASA), a widely used structured interview measuring pediatric mental health service use. Interviews (N = 72) were randomly selected from a pediatric effectiveness trial, and audio was coded by an independent rater. Regressions were employed to identify predictors of rater disagreement. Interrater reliability was high for items (> 94%) and summary metrics (ICC > .79) across service sectors. Predictors of disagreement varied by domain; significant predictors indexed higher clinical severity or social disadvantage. Results support the CASA as a reliable and robust assessment of pediatric service use, but administrators should be alert when assessing vulnerable populations.
Comparing Interrater reliability between eye examination and eye self-examination 1
de Lima, Maria Alzete; Pagliuca, Lorita Marlena Freitag; do Nascimento, Jennara Cândido; Caetano, Joselany Áfio
2017-01-01
Resume Objective: to compare Interrater reliability concerning two eye assessment methods. Method: quasi-experimental study conducted with 324 college students including eye self-examination and eye assessment performed by the researchers in a public university. Kappa coefficient was used to verify agreement. Results: reliability coefficients between Interraters ranged from 0.85 to 0.95, with statistical significance at 0.05. The exams to check for near acuity and peripheral vision presented a reasonable kappa >0.2. The remaining coefficients were higher, ranging from very to totally reliable. Conclusion: comparatively, the results of both methods were similar. The virtual manual on eye self-examination can be used to screen for eye conditions. PMID:29069269
An Investigation of "Honesty Check" Items in Higher Education Course Evaluations
ERIC Educational Resources Information Center
Bradley, Kelly D.; Royal, Kenneth D.; Bradley, James W.
2008-01-01
The reliability and validity of course evaluations in higher education is often assumed. The typical Likert-type surveys utilized when students' evaluate the course and instructor often overlook measurement issues, or deal with them in an ineffective manner. Given the importance that is placed on higher education course evaluations, with results…
The reliability of the Australasian Triage Scale: a meta-analysis
Ebrahimi, Mohsen; Heydari, Abbas; Mazlom, Reza; Mirhaghi, Amir
2015-01-01
BACKGROUND: Although the Australasian Triage Scale (ATS) has been developed two decades ago, its reliability has not been defined; therefore, we present a meta-analyis of the reliability of the ATS in order to reveal to what extent the ATS is reliable. DATA SOURCES: Electronic databases were searched to March 2014. The included studies were those that reported samples size, reliability coefficients, and adequate description of the ATS reliability assessment. The guidelines for reporting reliability and agreement studies (GRRAS) were used. Two reviewers independently examined abstracts and extracted data. The effect size was obtained by the z-transformation of reliability coefficients. Data were pooled with random-effects models, and meta-regression was done based on the method of moment’s estimator. RESULTS: Six studies were included in this study at last. Pooled coefficient for the ATS was substantial 0.428 (95%CI 0.340–0.509). The rate of mis-triage was less than fifty percent. The agreement upon the adult version is higher than the pediatric version. CONCLUSION: The ATS has shown an acceptable level of overall reliability in the emergency department, but it needs more development to reach an almost perfect agreement. PMID:26056538
Snow water equivalent in the Alps as seen by gridded data sets, CMIP5 and CORDEX climate models
NASA Astrophysics Data System (ADS)
Terzago, Silvia; von Hardenberg, Jost; Palazzi, Elisa; Provenzale, Antonello
2017-07-01
The estimate of the current and future conditions of snow resources in mountain areas would require reliable, kilometre-resolution, regional-observation-based gridded data sets and climate models capable of properly representing snow processes and snow-climate interactions. At the moment, the development of such tools is hampered by the sparseness of station-based reference observations. In past decades passive microwave remote sensing and reanalysis products have mainly been used to infer information on the snow water equivalent distribution. However, the investigation has usually been limited to flat terrains as the reliability of these products in mountain areas is poorly characterized.This work considers the available snow water equivalent data sets from remote sensing and from reanalyses for the greater Alpine region (GAR), and explores their ability to provide a coherent view of the snow water equivalent distribution and climatology in this area. Further we analyse the simulations from the latest-generation regional and global climate models (RCMs, GCMs), participating in the Coordinated Regional Climate Downscaling Experiment over the European domain (EURO-CORDEX) and in the Fifth Coupled Model Intercomparison Project (CMIP5) respectively. We evaluate their reliability in reproducing the main drivers of snow processes - near-surface air temperature and precipitation - against the observational data set EOBS, and compare the snow water equivalent climatology with the remote sensing and reanalysis data sets previously considered. We critically discuss the model limitations in the historical period and we explore their potential in providing reliable future projections.The results of the analysis show that the time-averaged spatial distribution of snow water equivalent and the amplitude of its annual cycle are reproduced quite differently by the different remote sensing and reanalysis data sets, which in fact exhibit a large spread around the ensemble mean. We find that GCMs at spatial resolutions equal to or finer than 1.25° longitude are in closer agreement with the ensemble mean of satellite and reanalysis products in terms of root mean square error and standard deviation than lower-resolution GCMs. The set of regional climate models from the EURO-CORDEX ensemble provides estimates of snow water equivalent at 0.11° resolution that are locally much larger than those indicated by the gridded data sets, and only in a few cases are these differences smoothed out when snow water equivalent is spatially averaged over the entire Alpine domain. ERA-Interim-driven RCM simulations show an annual snow cycle that is comparable in amplitude to those provided by the reference data sets, while GCM-driven RCMs present a large positive bias. RCMs and higher-resolution GCM simulations are used to provide an estimate of the snow reduction expected by the mid-21st century (RCP 8.5 scenario) compared to the historical climatology, with the main purpose of highlighting the limits of our current knowledge and the need for developing more reliable snow simulations.
NASA Technical Reports Server (NTRS)
1970-01-01
Reliability Abstracts and Technical Reviews is an abstract and critical analysis service covering published and report literature on reliability. The service is designed to provide information on theory and practice of reliability as applied to aerospace and an objective appraisal of the quality, significance, and applicability of the literature abstracted.
Reliability and Availability Evaluation Program Manual.
1982-11-01
research and development. The manual’s purpose was to provide a practical method for making reliability measurements, measurements directly related to... Research , Development, Test and Evaluation. RMA Reliability, Maintainability and Availability. R&R Repair and Refurbishment, Repair and Replacement, etc...length. phenomena such as mechanical wear and A number of researchers in the reliability chemical deterioration. Maintenance should field 14-pages 402
Examining the reliability of ADAS-Cog change scores.
Grochowalski, Joseph H; Liu, Ying; Siedlecki, Karen L
2016-09-01
The purpose of this study was to estimate and examine ways to improve the reliability of change scores on the Alzheimer's Disease Assessment Scale, Cognitive Subtest (ADAS-Cog). The sample, provided by the Alzheimer's Disease Neuroimaging Initiative, included individuals with Alzheimer's disease (AD) (n = 153) and individuals with mild cognitive impairment (MCI) (n = 352). All participants were administered the ADAS-Cog at baseline and 1 year, and change scores were calculated as the difference in scores over the 1-year period. Three types of change score reliabilities were estimated using multivariate generalizability. Two methods to increase change score reliability were evaluated: reweighting the subtests of the scale and adding more subtests. Reliability of ADAS-Cog change scores over 1 year was low for both the AD sample (ranging from .53 to .64) and the MCI sample (.39 to .61). Reweighting the change scores from the AD sample improved reliability (.68 to .76), but lengthening provided no useful improvement for either sample. The MCI change scores had low reliability, even with reweighting and adding additional subtests. The ADAS-Cog scores had low reliability for measuring change. Researchers using the ADAS-Cog should estimate and report reliability for their use of the change scores. The ADAS-Cog change scores are not recommended for assessment of meaningful clinical change.
Purba, Fredrick Dermawan; Hunfeld, Joke A M; Iskandarsyah, Aulia; Fitriana, Titi Sahidah; Sadarjoen, Sawitri S; Passchier, Jan; Busschbach, Jan J V
2018-01-01
The objective of this study is to obtain population norms and to assess test-retest reliability of EQ-5D-5L and WHOQOL-BREF for the Indonesian population. A representative sample of 1056 people aged 17-75 years was recruited from the Indonesian general population. We used a multistage stratified quota sampling method with respect to residence, gender, age, education level, religion and ethnicity. Respondents completed EQ-5D-5L and WHOQOL-BREF with help from an interviewer. Norms data for both instruments were reported. For the test-retest evaluations, a sub-sample of 206 respondents completed both instruments twice. The total sample and test-retest sub-sample were representative of the Indonesian general population. The EQ-5D-5L shows almost perfect agreement between the two tests (Gwet's AC: 0.85-0.99 and percentage agreement: 90-99%) regarding the five dimensions. However, the agreement of EQ-VAS and index scores can be considered as poor (ICC: 0.45 and 0.37 respectively). For the WHOQOL-BREF, ICCs of the four domains were between 0.70 and 0.79, which indicates moderate to good agreement. For EQ-5D-5L, it was shown that female and older respondents had lower EQ-index scores, whilst rural, younger and higher-educated respondents had higher EQ-VAS scores. For WHOQOL-BREF: male, younger, higher-educated, high-income respondents had the highest scores in most of the domains, overall quality of life, and health satisfaction. This study provides representative estimates of self-reported health status and quality of life for the general Indonesian population as assessed by the EQ-5D-5L and WHOQOL-BREF instruments. The descriptive system of the EQ-5D-5L and the WHOQOL-BREF have high test-retest reliability while the EQ-VAS and the index score of EQ-5D-5L show poor agreement between the two tests. Our results can be useful to researchers and clinicians who can compare their findings with respect to these concepts with those of the Indonesian general population.
Survey of Software Assurance Techniques for Highly Reliable Systems
NASA Technical Reports Server (NTRS)
Nelson, Stacy
2004-01-01
This document provides a survey of software assurance techniques for highly reliable systems including a discussion of relevant safety standards for various industries in the United States and Europe, as well as examples of methods used during software development projects. It contains one section for each industry surveyed: Aerospace, Defense, Nuclear Power, Medical Devices and Transportation. Each section provides an overview of applicable standards and examples of a mission or software development project, software assurance techniques used and reliability achieved.
On-clip high frequency reliability and failure test structures
Snyder, E.S.; Campbell, D.V.
1997-04-29
Self-stressing test structures for realistic high frequency reliability characterizations. An on-chip high frequency oscillator, controlled by DC signals from off-chip, provides a range of high frequency pulses to test structures. The test structures provide information with regard to a variety of reliability failure mechanisms, including hot-carriers, electromigration, and oxide breakdown. The system is normally integrated at the wafer level to predict the failure mechanisms of the production integrated circuits on the same wafer. 22 figs.
Thermal Fatigue Evaluation of Pb-Free Solder Joints: Results, Lessons Learned, and Future Trends
NASA Astrophysics Data System (ADS)
Coyle, Richard J.; Sweatman, Keith; Arfaei, Babak
2015-09-01
Thermal fatigue is a major source of failure of solder joints in surface mount electronic components and it is critically important in high reliability applications such as telecommunication, military, and aeronautics. The electronic packaging industry has seen an increase in the number of Pb-free solder alloy choices beyond the common near-eutectic Sn-Ag-Cu alloys first established as replacements for eutectic SnPb. This paper discusses the results from Pb-free solder joint reliability programs sponsored by two industry consortia. The characteristic life in accelerated thermal cycling is reported for 12 different Pb-free solder alloys and a SnPb control in 9 different accelerated thermal cycling test profiles in terms of the effects of component type, accelerated thermal cycling profile and dwell time. Microstructural analysis on assembled and failed samples was performed to investigate the effect of initial microstructure and its evolution during accelerated thermal cycling test. A significant finding from the study is that the beneficial effect of Ag on accelerated thermal cycling reliability (measured by characteristic lifetime) diminishes as the severity of the accelerated thermal cycling, defined by greater ΔT, higher peak temperature, and longer dwell time increases. The results also indicate that all the Pb-free solders are more reliable in accelerated thermal cycling than the SnPb alloy they have replaced. Suggestions are made for future work, particularly with respect to the continued evolution of alloy development for emerging application requirements and the value of using advanced analytical methods to provide a better understanding of the effect of microstructure and its evolution on accelerated thermal cycling performance.
McKendrick, Ryan; Shaw, Tyler; de Visser, Ewart; Saqer, Haneen; Kidwell, Brian; Parasuraman, Raja
2014-05-01
Assess team performance within a net-worked supervisory control setting while manipulating automated decision aids and monitoring team communication and working memory ability. Networked systems such as multi-unmanned air vehicle (UAV) supervision have complex properties that make prediction of human-system performance difficult. Automated decision aid can provide valuable information to operators, individual abilities can limit or facilitate team performance, and team communication patterns can alter how effectively individuals work together. We hypothesized that reliable automation, higher working memory capacity, and increased communication rates of task-relevant information would offset performance decrements attributed to high task load. Two-person teams performed a simulated air defense task with two levels of task load and three levels of automated aid reliability. Teams communicated and received decision aid messages via chat window text messages. Task Load x Automation effects were significant across all performance measures. Reliable automation limited the decline in team performance with increasing task load. Average team spatial working memory was a stronger predictor than other measures of team working memory. Frequency of team rapport and enemy location communications positively related to team performance, and word count was negatively related to team performance. Reliable decision aiding mitigated team performance decline during increased task load during multi-UAV supervisory control. Team spatial working memory, communication of spatial information, and team rapport predicted team success. An automated decision aid can improve team performance under high task load. Assessment of spatial working memory and the communication of task-relevant information can help in operator and team selection in supervisory control systems.
Scamell, Mandie; Hanley, Thomas
2018-03-01
A major issue regarding the implementation of blended learning for preregistration health programmes is the analysis of students' perceptions and attitudes towards their learning. It is the extent of the embedding of Technology Enhanced Learning (TEL) into the higher education curriculum that makes this analysis so vital. This paper reports on the quantitative results of a UK based study that was set up to respond to the apparent disconnect between technology enhanced education provision and reliable student evaluation of this mode of learning. Employing a mixed methods research design, the research described here was carried to develop a reliable and valid evaluation tool to measure acceptability of and satisfaction with a blended learning approach, specifically designed for a preregistration midwifery module offered at level 4. Feasibility testing of 46 completed blended learning evaluation questionnaires - Student Midwife Evaluation of Online Learning Effectiveness (SMEOLE) - using descriptive statistics, reliability and internal consistency tests. Standard deviations and mean scores all followed predicted pattern. Results from the reliability and internal consistency testing confirm the feasibility of SMEOLE as an effective tool for measuring student satisfaction with a blended learning approach to preregistration learning. The analysis presented in this paper suggests that we have been successful in our aim to produce an evaluation tool capable of assessing the quality of technology enhanced, University level learning in Midwifery. This work can provide future benchmarking against which midwifery, and other health, blended learning curriculum planning could be structured and evaluated. Copyright © 2017 Elsevier Ltd. All rights reserved.
75 FR 72664 - System Personnel Training Reliability Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-26
...Under section 215 of the Federal Power Act, the Commission approves two Personnel Performance, Training and Qualifications (PER) Reliability Standards, PER-004-2 (Reliability Coordination--Staffing) and PER-005-1 (System Personnel Training), submitted to the Commission for approval by the North American Electric Reliability Corporation, the Electric Reliability Organization certified by the Commission. The approved Reliability Standards require reliability coordinators, balancing authorities, and transmission operators to establish a training program for their system operators, verify each of their system operators' capability to perform tasks, and provide emergency operations training to every system operator. The Commission also approves NERC's proposal to retire two existing PER Reliability Standards that are replaced by the standards approved in this Final Rule.
Public trust in Dutch health care.
Straten, G F M; Friele, R D; Groenewegen, P P
2002-07-01
This article describes the development of a valid and reliable instrument to measure different dimensions of public trust in health care in the Netherlands. This instrument is needed because the concept was not well developed, or operationalized in earlier research. The new instrument will be used in a research project to monitor trust and to predict behaviour of people such as consulting "alternative practitioners". The idea for the research was suggested by economic research into public trust. In the study, a phased design was used to overcome the operationalization problem. In the first phase, a qualitative study was conducted; and, in the second, a quantitative study. In the first phase, more than 100 people were interviewed to gain insight into the issues they associated with trust. Eight categories of issues that were derived from the interviews were assumed to be possible dimensions of trust. On the basis of these eight categories and the interviews, a questionnaire was developed that was used in the second phase. In this phase, the questionnaire was sent to 1500 members of a consumer panel; the response was 70 percent. The analysis reveals that six of the eight possible dimensions appear in factor analysis. These dimensions are trust in: the patient-focus of health care providers; macro policies level will have no consequences for patients; expertise of health care providers; quality of care; information supply and communication by care providers and the quality of cooperation. The reliability of most scales is higher than 0.8. The validity of the dimensions is assessed by determining the correlation between the scales on the one hand, and people's experience and a general mark they would assign on the other. We conclude that public trust is a multi-dimensional concept, including not only issues that relate to the patient-doctor relationship, but also issues that relate to health care institutions. The instrument appears to be reliable and valid.
Helicobacter pylori therapy: a paradigm shift
Graham, David Y; Dore, Maria Pina
2016-01-01
SUMMARY Helicobacter pylori (H. Pylori) is a leading cause of gastroduodenal disease, including gastric cancer. H. pylori eradication therapies and their efficacy are summarized. A number of current treatment regimens will reliably yield >90% or 95% cure rates with susceptible strains. None has proven to be superior. We show how to predict the efficacy of a regimen in any population provided one knows the prevalence of antibiotic resistance. As with other infectious diseases, therapy should always be susceptibility-based. Susceptibility testing should be demanded. We provide recommendations for empiric therapies when the only option and describe how to distinguish studies providing misinformation from those providing reliable and interpretable data. When treated as an infectious disease, high H. pylori cure rates are relatively simple to reliably achieve. PMID:27077447
Developing safety performance functions incorporating reliability-based risk measures.
Ibrahim, Shewkar El-Bassiouni; Sayed, Tarek
2011-11-01
Current geometric design guides provide deterministic standards where the safety margin of the design output is generally unknown and there is little knowledge of the safety implications of deviating from these standards. Several studies have advocated probabilistic geometric design where reliability analysis can be used to account for the uncertainty in the design parameters and to provide a risk measure of the implication of deviation from design standards. However, there is currently no link between measures of design reliability and the quantification of safety using collision frequency. The analysis presented in this paper attempts to bridge this gap by incorporating a reliability-based quantitative risk measure such as the probability of non-compliance (P(nc)) in safety performance functions (SPFs). Establishing this link will allow admitting reliability-based design into traditional benefit-cost analysis and should lead to a wider application of the reliability technique in road design. The present application is concerned with the design of horizontal curves, where the limit state function is defined in terms of the available (supply) and stopping (demand) sight distances. A comprehensive collision and geometric design database of two-lane rural highways is used to investigate the effect of the probability of non-compliance on safety. The reliability analysis was carried out using the First Order Reliability Method (FORM). Two Negative Binomial (NB) SPFs were developed to compare models with and without the reliability-based risk measures. It was found that models incorporating the P(nc) provided a better fit to the data set than the traditional (without risk) NB SPFs for total, injury and fatality (I+F) and property damage only (PDO) collisions. Copyright © 2011 Elsevier Ltd. All rights reserved.
Tsuno, Kanami; Kawakami, Norito; Shimazu, Akihito; Shimada, Kyoko; Inoue, Akiomi; P Leiter, Michael
2017-05-25
Although incivility is a common interpersonal mistreatment and associated with poor mental health, there are few studies about it in Asian countries. The aim of this study was to develop the Japanese version of the modified Work Incivility Scale (J-MWIS), investigate its reliability and validity, and reveal the prevalence of incivility among Japanese employees in comparison with data on Canadian employees. A total of 2,191 Japanese and 1,071 Canadian employees were surveyed, using either the J-MWIS or MWIS. Japanese employees additionally answered questions on civility, worksite social support, workplace bullying, psychological distress, intention to leave, and work engagement to investigate construct validity. At least one form of workplace incivility was experienced by both Japanese (52.3%) and Canadian (86.0%) employees in the previous month. Internal consistency reliability of the J-MWIS was acceptable (α=0.71-0.81), and correlation analyses also confirmed its construct validity as expected. Workplace incivility was associated with lower workgroup civility, lower supervisor and coworker support, higher workplace bullying, higher psychological distress, higher intention to leave, and lower work engagement. Confirmatory factor analyses showed that the original three-factor model (supervisor incivility, coworker incivility, and instigated incivility) fitted moderately in both Japan and Canada data, though the privacy/overfamiliarity factor was additionally extracted from exploratory factor analysis for the J-MWIS. The results of this study suggested that the J-MWIS has moderate internal consistency reliability and good construct validity.
Tsuno, Kanami; Kawakami, Norito; Shimazu, Akihito; Shimada, Kyoko; Inoue, Akiomi; P. Leiter, Michael
2017-01-01
Objectives: Although incivility is a common interpersonal mistreatment and associated with poor mental health, there are few studies about it in Asian countries. The aim of this study was to develop the Japanese version of the modified Work Incivility Scale (J-MWIS), investigate its reliability and validity, and reveal the prevalence of incivility among Japanese employees in comparison with data on Canadian employees. Methods: A total of 2,191 Japanese and 1,071 Canadian employees were surveyed, using either the J-MWIS or MWIS. Japanese employees additionally answered questions on civility, worksite social support, workplace bullying, psychological distress, intention to leave, and work engagement to investigate construct validity. Results: At least one form of workplace incivility was experienced by both Japanese (52.3%) and Canadian (86.0%) employees in the previous month. Internal consistency reliability of the J-MWIS was acceptable (α=0.71-0.81), and correlation analyses also confirmed its construct validity as expected. Workplace incivility was associated with lower workgroup civility, lower supervisor and coworker support, higher workplace bullying, higher psychological distress, higher intention to leave, and lower work engagement. Confirmatory factor analyses showed that the original three-factor model (supervisor incivility, coworker incivility, and instigated incivility) fitted moderately in both Japan and Canada data, though the privacy/overfamiliarity factor was additionally extracted from exploratory factor analysis for the J-MWIS. Conclusions: The results of this study suggested that the J-MWIS has moderate internal consistency reliability and good construct validity. PMID:28302927
NASA Astrophysics Data System (ADS)
Masuwai, Azwani; Tajudin, Nor'ain Mohd; Saad, Noor Shah
2017-05-01
The purpose of this study is to develop and establish the validity and reliability of an instrument to generate teaching and learning guiding principles using Teaching and Learning Guiding Principles Instrument (TLGPI). Participants consisted of 171 Malaysian teacher educators. It is an essential instrument to reflect in generating the teaching and learning guiding principles in higher education level in Malaysia. Confirmatory Factor Analysis has validated all 19 items of TLGPI whereby all items indicated high reliability and internal consistency. A Confirmatory Factor Analysis also confirmed that a single factor model was used to generate teaching and learning guiding principles.
How reliable an indicator of inflammation is myeloperoxidase activity?
Faith, Minnie; Sukumaran, Abitha; Pulimood, Anna B; Jacob, Molly
2008-10-01
Myeloperoxidase (MPO) and interleukin-6 (IL-6) are often used as markers of inflammation. The aim of this study was to ascertain whether MPO activity is as reliable as IL-6 as an indicator of inflammation. Inflammation was induced in mice, using either turpentine or indomethacin. Duodenal tissue was removed from these animals at various time periods ranging from 6 h to 7 days later. Concentrations of IL-6 and MPO activity were estimated in the tissue. Histopathological examination was also carried out at some of the time periods to determine the presence of neutrophil infiltration in turpentine-treated mice. Concentrations of IL-6 and MPO activity were significantly higher in tissue that had been treated with the agents used, at all the time periods studied, when compared with corresponding control tissue. Fold-increases in MPO activity were higher than fold-increases in IL-6. Concentrations of the 2 parameters showed significant positive correlation. Histopathological examination did not show significantly higher numbers of neutrophils infiltrating the tissue in response to turpentine, at the time periods studied. Estimation of MPO activity is a reliable indicator of inflammation, being more sensitive than histopathological examination of tissue and as good as measurement of IL-6 concentrations.
Vahip, Simavi; Kesebir, Sermin; Alkan, Müge; Yazici, Olcay; Akiskal, Knarig K; Akiskal, Hagop S
2005-03-01
This is a first attempt to evaluate the reliability and factor structure replicability of the Temperament Evaluation of Memphis, Pisa, Paris and San Diego Autoquestionnaire (TEMPS-A) in its Turkish Version. The questionnaire is a self-report 110-item measure that postulates five affective temperaments-the depressive, cyclothymic, irritable, hyperthymic, and anxious-which embody both strengths and liabilities along affective lines. The questionnaire was administered to 658 clinically-well subjects in a Turkish university circle. We undertook item analysis and test-retest reliability. We then examined internal consistency through factor analysis with PCA rotation. We found good to excellent test-retest reliability (0.73-0.91), and internal consistency (0.77-0.85). We deleted 10 items with factor loading <0.20 for their own subscales, resulting in a questionnaire with 99 items. Despite considerable overlap between depressive and cognitive anxiety traits, a distinct "nervous"-anxious factor emerged as well, and the hypothesized (original English) 5-factor structure of the TEMPS-A was supported. Cut-offs for each temperament were based on z-scores higher than +2S.D. Dominant irritable (3.7%), nervous-anxious (3.7%) and depressive (3.1%) temperaments were the most common in this population, whereas dominant cyclothymic (1.7%) and hyperthymic (1.2%) temperaments were relatively uncommon. These temperaments tended to lose their intensity with age. As expected, women scored significantly higher on the nervous-anxious, and men on the hyperthymic temperaments. The sample was composed of younger subjects with higher education than the general population of Turkey. Although the distribution of the scores for each of the temperaments deviated somewhat from normal curves, for heuristic reasons we did attempt to provide prevalence rates based on z-scores. In this preliminary version of the TEMPS-A, we have retained 100 (of the original 110) traits loading >0.20. Some deleted items referred to sleep, others appeared socially desirability traits in the Turkish culture endorsed by many subjects. Nonetheless, item analyses within each factor revealed traits indicative of personal assets (specific to each temperament) along with those which might represent vulnerability to affective illness. This is in line with the hypothesized original theoretical framework of the senior authors. Even in this "first pass," in its Turkish version the TEMPS-A is a reliable and valid instrument. Further refinement of the instrument will require the study of a nationally representative sample in Turkey.
Reliable intraocular pressure measurement using automated radio-wave telemetry
Paschalis, Eleftherios I; Cade, Fabiano; Melki, Samir; Pasquale, Louis R; Dohlman, Claes H; Ciolino, Joseph B
2014-01-01
Purpose To present an autonomous intraocular pressure (IOP) measurement technique using a wireless implantable transducer (WIT) and a motion sensor. Methods The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS) comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline) IOP. Results On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg) and mean vehicle IOP (13.27±2.1 mmHg) (P=0.45), suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001), and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001). Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001). Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute), during which the IOP is not expected to change. Conclusion IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results. PMID:24531415
Murphy, Kelly R; McManigle, John E; Wildman-Tobriner, Benjamin M; Little Jones, Amy; Dekker, Travis J; Little, Barrett A; Doty, Joseph P; Taylor, Dean C
2016-01-01
The medical community has recognized the importance of leadership skills among its members. While numerous leadership assessment tools exist at present, few are specifically tailored to the unique health care environment. The study team designed a 24-item survey (Healthcare Evaluation & Assessment of Leadership [HEAL]) to measure leadership competency based on the core competencies and core principles of the Duke Healthcare Leadership Model. A novel digital platform was created for use on handheld devices to facilitate its distribution and completion. This pilot phase involved 126 health care professionals self-assessing their leadership abilities. The study aimed to determine both the content validity of the survey and the feasibility of its implementation and use. The digital platform for survey implementation was easy to complete, and there were no technical problems with survey use or data collection. With regard to reliability, initial survey results revealed that each core leadership tenet met or exceeded the reliability cutoff of 0.7. In self-assessment of leadership, women scored themselves higher than men in questions related to patient centeredness (P=0.016). When stratified by age, younger providers rated themselves lower with regard to emotional intelligence and integrity. There were no differences in self-assessment when stratified by medical specialty. While only a pilot study, initial data suggest that HEAL is a reliable and easy-to-administer survey for health care leadership assessment. Differences in responses by sex and age with respect to patient centeredness, integrity, and emotional intelligence raise questions about how providers view themselves amid complex medical teams. As the survey is refined and further administered, HEAL will be used not only as a self-assessment tool but also in “360” evaluation formats. PMID:29355186
Murphy, Kelly R; McManigle, John E; Wildman-Tobriner, Benjamin M; Little Jones, Amy; Dekker, Travis J; Little, Barrett A; Doty, Joseph P; Taylor, Dean C
2016-01-01
The medical community has recognized the importance of leadership skills among its members. While numerous leadership assessment tools exist at present, few are specifically tailored to the unique health care environment. The study team designed a 24-item survey (Healthcare Evaluation & Assessment of Leadership [HEAL]) to measure leadership competency based on the core competencies and core principles of the Duke Healthcare Leadership Model. A novel digital platform was created for use on handheld devices to facilitate its distribution and completion. This pilot phase involved 126 health care professionals self-assessing their leadership abilities. The study aimed to determine both the content validity of the survey and the feasibility of its implementation and use. The digital platform for survey implementation was easy to complete, and there were no technical problems with survey use or data collection. With regard to reliability, initial survey results revealed that each core leadership tenet met or exceeded the reliability cutoff of 0.7. In self-assessment of leadership, women scored themselves higher than men in questions related to patient centeredness ( P =0.016). When stratified by age, younger providers rated themselves lower with regard to emotional intelligence and integrity. There were no differences in self-assessment when stratified by medical specialty. While only a pilot study, initial data suggest that HEAL is a reliable and easy-to-administer survey for health care leadership assessment. Differences in responses by sex and age with respect to patient centeredness, integrity, and emotional intelligence raise questions about how providers view themselves amid complex medical teams. As the survey is refined and further administered, HEAL will be used not only as a self-assessment tool but also in "360" evaluation formats.
Pfeiffer, Christoph; Ruffieux, Silvia; Jousmäki, Veikko; Hämäläinen, Matti; Schneiderman, Justin F.; Lundqvist, Daniel
2017-01-01
The development of new magnetic sensor technologies that promise sensitivities approaching that of conventional MEG technology while operating at far lower operating temperatures has catalysed the growing field of on-scalp MEG. The feasibility of on-scalp MEG has been demonstrated via benchmarking of new sensor technologies performing neuromagnetic recordings in close proximity to the head surface against state-of-the-art in-helmet MEG sensor technology. However, earlier work has provided little information about how these two approaches compare, or about the reliability of observed differences. Herein, we present such a comparison, based on recordings of the N20m component of the somatosensory evoked field as elicited by electric median nerve stimulation. As expected from the proximity differences between the on-scalp and in-helmet sensors, the magnitude of the N20m activation as recorded with the on-scalp sensor was higher than that of the in-helmet sensors. The dipole pattern of the on-scalp recordings was also more spatially confined than that of the conventional recordings. Our results furthermore revealed unexpected temporal differences in the peak of the N20m component. An analysis protocol was therefore developed for assessing the reliability of this observed difference. We used this protocol to examine our findings in terms of differences in sensor sensitivity between the two types of MEG recordings. The measurements and subsequent analysis raised attention to the fact that great care has to be taken in measuring the field close to the zero-line crossing of the dipolar field, since it is heavily dependent on the orientation of sensors. Taken together, our findings provide reliable evidence that on-scalp and in-helmet sensors measure neural sources in mostly similar ways. PMID:28742118
Zurlo, Maria Clelia; Pes, Daniela; Siegrist, Johannes
2010-08-01
This study explores the explicative potential of effort-reward imbalance Model to unveil the dimensions involved in teacher stress process and analyses the psychometric characteristics of the Italian version of the ERI Questionnaire (Siegrist, J Occup Health Psychol 1:27-43, 1996) with respect to a homogeneous occupational group: Italian school teachers. The Italian version of the ERI Questionnaire was submitted to 673 teachers randomly drawn from a cross-section of school types. Internal consistency, reliability, discriminative validity, and factorial structure were evaluated. Predictive validity was explored with respect to a measure of perceived strain, the Crown-Crisp Experiential Index. Discriminative validity was explored with respect to age, gender, education, type of school, the presence/absence of physical pains in the last 12 months before the survey, and teachers' intention to leave the profession. Item-total correlations are for all items included between 0.30 and 0.80 (p < 0.01). Mean inter-item correlation is 0.26. Cronbach's alpha for the whole questionnaire reaches the value of 0.89. The factor analysis identified four reliable factors that accounted for 44.8 per cent of the total variance and which confirmed the basic structure emerged from previous studies yet highlighting two instead of three different components for reward. Higher efforts (T = -3.82, p < 0.001) and both lower material (T = 3.23, p < 0.001) and immaterial rewards (T = 3.17, p < 0.005) characterised the group of teachers, which reported to suffer for physical pains. Higher efforts (T = -5.26, p < 0.001), higher overcommitment (T = -3.15, p < 0.005), and both lower material (T = 4.63, p < 0.001) and immaterial rewards (T = 4.00, p < 0.001) were observed in the group of teachers inclined to give up the job. Multiple regression analyses have highlighted that higher efforts, higher overcommitment, and lower rewards are significantly predictive of higher levels of free-floating and somatic anxiety as well as depression and global psychological strain. This preliminary analysis of the reliability and validity of the Italian version of the ERI Questionnaire reveals that it constitutes a useful and reliable measure to analyse work-related stress with respect to the school setting. The validity of the ERI model to describe the dimensions involved in teacher's stress and to highlight those associated to leaving intentions and to several physical and psychological strain outcomes in Italian school teachers has been confirmed.
Is the medical justice system broken?
Howard, Philip K
2003-09-01
The current lawsuit culture is creating a crisis in US health care. The broad perception that anyone can sue for almost anything has fundamentally altered the practice of medicine, eroding the quality and availability of health care. Current reform proposals to "cap" one category of damages are not nearly ambitious enough. Providing relief to doctors squeezed by insurance premiums is important but will not heal the deep distrust that skews daily decisions, nor will it provide incentives to overhaul outdated practices. The United States needs an entirely new system of medical justice. Its first goal is to be reliable: reliable in protecting patients against bad practices, reliable in protecting physicians who act reasonably, and reliable in interpreting standards of care.
Performance Issues for a Changing Electric Power Industry
1995-01-01
Provides an overview of some of the factors affecting reliability within the electric bulk power system. Historical and projected data related to reliability issues are discussed on a national and regional basis. Current research on economic considerations associated with reliability levels is also reviewed.
78 FR 49595 - Aviation Rulemaking Advisory Committee-New Task
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-14
... the new ARAC activity and solicits membership for the Maintenance Reliability Program Working Group... establish the Maintenance Reliability Program Working Group. The working group will serve as staff to ARAC... programs. The Maintenance Reliability Program Working Group will provide advice and recommendations on the...
Pre- and postprocessing techniques for determining goodness of computational meshes
NASA Technical Reports Server (NTRS)
Oden, J. Tinsley; Westermann, T.; Bass, J. M.
1993-01-01
Research in error estimation, mesh conditioning, and solution enhancement for finite element, finite difference, and finite volume methods has been incorporated into AUDITOR, a modern, user-friendly code, which operates on 2D and 3D unstructured neutral files to improve the accuracy and reliability of computational results. Residual error estimation capabilities provide local and global estimates of solution error in the energy norm. Higher order results for derived quantities may be extracted from initial solutions. Within the X-MOTIF graphical user interface, extensive visualization capabilities support critical evaluation of results in linear elasticity, steady state heat transfer, and both compressible and incompressible fluid dynamics.
Cyber Security and Reliability in a Digital Cloud
2013-01-01
a higher utilization of servers, lower professional support staff needs, economies of scale for the physical facility, and the flexibility to locate...as a system, the DoD can achieve the economies of scale typically associated with large data centers. Recommendation 3: The DoD CIO and DISA...providers will help set standards for secure cloud computing across the economy . Recommendation 7: The DoD CIO and DISA should participate in the
Structured Low-Density Parity-Check Codes with Bandwidth Efficient Modulation
NASA Technical Reports Server (NTRS)
Cheng, Michael K.; Divsalar, Dariush; Duy, Stephanie
2009-01-01
In this work, we study the performance of structured Low-Density Parity-Check (LDPC) Codes together with bandwidth efficient modulations. We consider protograph-based LDPC codes that facilitate high-speed hardware implementations and have minimum distances that grow linearly with block sizes. We cover various higher- order modulations such as 8-PSK, 16-APSK, and 16-QAM. During demodulation, a demapper transforms the received in-phase and quadrature samples into reliability information that feeds the binary LDPC decoder. We will compare various low-complexity demappers and provide simulation results for assorted coded-modulation combinations on the additive white Gaussian noise and independent Rayleigh fading channels.
NASA Astrophysics Data System (ADS)
Zhang, L. F.; Chen, D. Y.; Wang, Q.; Li, H.; Zhao, Z. G.
2018-01-01
A preparation technology of ultra-thin Carbon-fiber paper is reported. Carbon fiber distribution homogeneity has a great influence on the properties of ultra-thin Carbon-fiber paper. In this paper, a self-developed homogeneity analysis system is introduced to assist users to evaluate the distribution homogeneity of Carbon fiber among two or more two-value images of carbon-fiber paper. A relative-uniformity factor W/H is introduced. The experimental results show that the smaller the W/H factor, the higher uniformity of the distribution of Carbon fiber is. The new uniformity-evaluation method provides a practical and reliable tool for analyzing homogeneity of materials.
[Reflection of estimating postmortem interval in forensic entomology and the Daubert standard].
Xie, Dan; Peng, Yu-Long; Guo, Ya-Dong; Cai, Ji-Feng
2013-08-01
Estimating postmortem interval (PMI) is always the emphasis and difficulty in forensic practice. Forensic entomology plays a significant indispensable role. Recently, the theories and technologies of forensic entomology are increasingly rich. But many problems remain in the research and practice. With proposing the Daubert standard, the reliability and accuracy of estimation PMI by forensic entomology need more demands. This review summarizes the application of the Daubert standard in several aspects of ecology, quantitative genetics, population genetics, molecular biology, and microbiology in the practice of forensic entomology. It builds a bridge for basic research and forensic practice to provide higher accuracy for estimating postmortem interval by forensic entomology.
NASA Technical Reports Server (NTRS)
Handley, Thomas H., Jr.; Preheim, Larry E.
1990-01-01
Data systems requirements in the Earth Observing System (EOS) Space Station Freedom (SSF) eras indicate increasing data volume, increased discipline interplay, higher complexity and broader data integration and interpretation. A response to the needs of the interdisciplinary investigator is proposed, considering the increasing complexity and rising costs of scientific investigation. The EOS Data Information System, conceived to be a widely distributed system with reliable communication links between central processing and the science user community, is described. Details are provided on information architecture, system models, intelligent data management of large complex databases, and standards for archiving ancillary data, using a research library, a laboratory and collaboration services.
ERIC Educational Resources Information Center
Mundia, Lawrence
2011-01-01
The survey investigated the problems of social desirability (SD), non-response bias (NRB) and reliability in the Minnesota Multiphasic Personality Inventory--Revised (MMPI-2) self-report inventory administered to Brunei student teachers. Bruneians scored higher on all the validity scales than the normative US sample, thereby threatening the…
The Reliability and Sources of Error of Using Rubrics-Based Assessment for Student Projects
ERIC Educational Resources Information Center
Menéndez-Varela, José-Luis; Gregori-Giralt, Eva
2018-01-01
Rubrics are widely used in higher education to assess performance in project-based learning environments. To date, the sources of error that may affect their reliability have not been studied in depth. Using generalisability theory as its starting-point, this article analyses the influence of the assessors and the criteria of the rubrics on the…
Fault recovery in the reliable multicast protocol
NASA Technical Reports Server (NTRS)
Callahan, John R.; Montgomery, Todd L.; Whetten, Brian
1995-01-01
The Reliable Multicast Protocol (RMP) provides a unique, group-based model for distributed programs that need to handle reconfiguration events at the application layer. This model, called membership views, provides an abstraction in which events such as site failures, network partitions, and normal join-leave events are viewed as group reformations. RMP provides access to this model through an application programming interface (API) that notifies an application when a group is reformed as the result of a some event. RMP provides applications with reliable delivery of messages using an underlying IP Multicast (12, 5) media to other group members in a distributed environment even in the case of reformations. A distributed application can use various Quality of Service (QoS) levels provided by RMP to tolerate group reformations. This paper explores the implementation details of the mechanisms in RMP that provide distributed applications with membership view information and fault recovery capabilities.
Specification and Design of a Fault Recovery Model for the Reliable Multicast Protocol
NASA Technical Reports Server (NTRS)
Montgomery, Todd; Callahan, John R.; Whetten, Brian
1996-01-01
The Reliable Multicast Protocol (RMP) provides a unique, group-based model for distributed programs that need to handle reconfiguration events at the application layer. This model, called membership views, provides an abstraction in which events such as site failures, network partitions, and normal join-leave events are viewed as group reformations. RMP provides access to this model through an application programming interface (API) that notifies an application when a group is reformed as the result of a some event. RMP provides applications with reliable delivery of messages using an underlying IP Multicast media to other group members in a distributed environment even in the case of reformations. A distributed application can use various Quality of Service (QoS) levels provided by RMP to tolerate group reformations. This paper explores the implementation details of the mechanisms in RMP that provide distributed applications with membership view information and fault recovery capabilities.
On the next generation of reliability analysis tools
NASA Technical Reports Server (NTRS)
Babcock, Philip S., IV; Leong, Frank; Gai, Eli
1987-01-01
The current generation of reliability analysis tools concentrates on improving the efficiency of the description and solution of the fault-handling processes and providing a solution algorithm for the full system model. The tools have improved user efficiency in these areas to the extent that the problem of constructing the fault-occurrence model is now the major analysis bottleneck. For the next generation of reliability tools, it is proposed that techniques be developed to improve the efficiency of the fault-occurrence model generation and input. Further, the goal is to provide an environment permitting a user to provide a top-down design description of the system from which a Markov reliability model is automatically constructed. Thus, the user is relieved of the tedious and error-prone process of model construction, permitting an efficient exploration of the design space, and an independent validation of the system's operation is obtained. An additional benefit of automating the model construction process is the opportunity to reduce the specialized knowledge required. Hence, the user need only be an expert in the system he is analyzing; the expertise in reliability analysis techniques is supplied.
Recent GE BWR fuel experience and design evolution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wood, J.E.; Potts, G.A.; Proebstle, R.A.
1992-01-01
Reliable fuel operation is essential to the safe, reliable, and economic power production by today's commercial nuclear reactors. GE Nuclear Energy is committed to maximize fuel reliability through the progressive development of improved fuel design features and dedication to provide the maximum quality of the design features and dedication to provide the maximum quality of the design, fabrication, and operation of GE BWR fuel. Over the last 35 years, GE has designed, fabricated, and placed in operation over 82,000 BWR fuel bundles containing over 5 million fuel rods. This experience includes successful commercial reactor operation of fuel assemblies to greatermore » than 45000 MWd/MTU bundle average exposure. This paper reports that this extensive experience base has enabled clear identification and characterization of the active failure mechanisms. With this failure mechanism characterization, mitigating actions have been developed and implemented by GE to provide the highest reliability BWR fuel bundles possible.« less
Gossamer-1: Mission concept and technology for a controlled deployment of gossamer spacecraft
NASA Astrophysics Data System (ADS)
Seefeldt, Patric; Spietz, Peter; Sproewitz, Tom; Grundmann, Jan Thimo; Hillebrandt, Martin; Hobbie, Catherin; Ruffer, Michael; Straubel, Marco; Tóth, Norbert; Zander, Martin
2017-01-01
Gossamer structures for innovative space applications, such as solar sails, require technology that allows their controlled and thereby safe deployment. Before employing such technology for a dedicated science mission, it is desirable, if not necessary, to demonstrate its reliability with a Technology Readiness Level (TRL) of six or higher. The aim of the work presented here is to provide reliable technology that enables the controlled deployment and verification of its functionality with various laboratory tests, thereby qualifying the hardware for a first demonstration in low Earth orbit (LEO). The development was made in the Gossamer-1 project of the German Aerospace Center (DLR). This paper provides an overview of the Gossamer-1 mission and hardware development. The system is designed based on the requirements of a technology demonstration mission. The design rests on a crossed boom configuration with triangular sail segments. Employing engineering models, all aspects of the deployment were tested under ambient environment. Several components were also subjected to environmental qualification testing. An innovative stowing and deployment strategy for a controlled deployment, as well as the designs of the bus system, mechanisms and electronics are described. The tests conducted provide insights into the deployment process and allow a mechanical characterization of that deployment process, in particular the measurement of the deployment forces. Deployment on system level could be successfully demonstrated to be robust and controllable. The deployment technology is on TRL four approaching level five, with a qualification model for environmental testing currently being built.
SIRGAS: the core geodetic infrastructure in Latin America and the Caribbean
NASA Astrophysics Data System (ADS)
Sanchez, L.; Brunini, C.; Drewes, H.; Mackern, V.; da Silva, A.
2013-05-01
Studying, understanding, and modelling geophysical phenomena, such as global change and geodynamics, require geodetic reference frames with (1) an order of accuracy higher than the magnitude of the effects we want to study, (2) consistency and reliability worldwide (the same accuracy everywhere), and (3) a long-term stability (the same order of accuracy at any time). The definition, realisation, maintenance, and wide-utilisation of the International Terrestrial Reference System (ITRS) are oriented to guarantee a globally unified geometric reference frame with reliability at the mm-level, i.e. the International Terrestrial Reference Frame (ITRF). The densification of the global ITRF in Latin America and The Caribbean is given by SIRGAS (Sistema de Referencia Geocéntrico para Las Américas), primary objective of which is to provide the most precise coordinates in the region. Therefore, SIRGAS is the backbone for all regional projects based on the generation, use, and analysis of geo-referenced data at national as well as at international level. Besides providing the reference for a wide range of scientific applications such as the monitoring of Earth's crust deformations, vertical movements, sea level variations, atmospheric studies, etc., SIRGAS is also the platform for practical applications such as engineering projects, digital administration of geographical data, geospatial data infrastructures, etc. According to this, the present contribution describes the main features of SIRGAS, giving special care to those challenges faced to continue providing the best possible, long-term stable and high-precise reference frame for Latin America and the Caribbean.
Short- and long-term reliability of language fMRI.
Nettekoven, Charlotte; Reck, Nicola; Goldbrunner, Roland; Grefkes, Christian; Weiß Lucas, Carolin
2018-08-01
When using functional magnetic resonance imaging (fMRI) for mapping important language functions, a high test-retest reliability is mandatory, both in basic scientific research and for clinical applications. We, therefore, systematically tested the short- and long-term reliability of fMRI in a group of healthy subjects using a picture naming task and a sparse-sampling fMRI protocol. We hypothesized that test-retest reliability might be higher for (i) speech-related motor areas than for other language areas and for (ii) the short as compared to the long intersession interval. 16 right-handed subjects (mean age: 29 years) participated in three sessions separated by 2-6 (session 1 and 2, short-term) and 21-34 days (session 1 and 3, long-term). Subjects were asked to perform the same overt picture naming task in each fMRI session (50 black-white images per session). Reliability was tested using the following measures: (i) Euclidean distances (ED) between local activation maxima and Centers of Gravity (CoGs), (ii) overlap volumes and (iii) voxel-wise intraclass correlation coefficients (ICCs). Analyses were performed for three regions of interest which were chosen based on whole-brain group data: primary motor cortex (M1), superior temporal gyrus (STG) and inferior frontal gyrus (IFG). Our results revealed that the activation centers were highly reliable, independent of the time interval, ROI or hemisphere with significantly smaller ED for the local activation maxima (6.45 ± 1.36 mm) as compared to the CoGs (8.03 ± 2.01 mm). In contrast, the extent of activation revealed rather low reliability values with overlaps ranging from 24% (IFG) to 56% (STG). Here, the left hemisphere showed significantly higher overlap volumes than the right hemisphere. Although mean ICCs ranged between poor (ICC<0.5) and moderate (ICC 0.5-0.74) reliability, highly reliable voxels (ICC>0.75) were found for all ROIs. Voxel-wise reliability of the different ROIs was influenced by the intersession interval. Taken together, we could show that, despite of considerable ROI-dependent variations of the extent of activation over time, highly reliable centers of activation can be identified using an overt picture naming paradigm. Copyright © 2018 Elsevier Inc. All rights reserved.
Chung, Chia-Fang; Xu, Kaiyuan; Dong, Yi; Schenk, Jeanette M.; Cain, Kevin; Munson, Sean; Heitkemper, Margaret M.
2017-01-01
There are currently no standardized methods for identifying trigger food(s) from irritable bowel syndrome (IBS) food and symptom journals. The primary aim of this study was to assess the inter-rater reliability of providers’ interpretations of IBS journals. A second aim was to describe whether these interpretations varied for each patient. Eight providers reviewed 17 IBS journals and rated how likely key food groups (fermentable oligo-di-monosaccharides and polyols, high-calorie, gluten, caffeine, high-fiber) were to trigger IBS symptoms for each patient. Agreement of trigger food ratings was calculated using Krippendorff’s α-reliability estimate. Providers were also asked to write down recommendations they would give to each patient. Estimates of agreement of trigger food likelihood ratings were poor (average α = 0.07). Most providers gave similar trigger food likelihood ratings for over half the food groups. Four providers gave the exact same written recommendation(s) (range 3–7) to over half the patients. Inter-rater reliability of provider interpretations of IBS food and symptom journals was poor. Providers favored certain trigger food likelihood ratings and written recommendations. This supports the need for a more standardized method for interpreting these journals and/or more rigorous techniques to accurately identify personalized IBS food triggers. PMID:29113044
High-Performance, Reliable Multicasting: Foundations for Future Internet Groupware Applications
NASA Technical Reports Server (NTRS)
Callahan, John; Montgomery, Todd; Whetten, Brian
1997-01-01
Network protocols that provide efficient, reliable, and totally-ordered message delivery to large numbers of users will be needed to support many future Internet applications. The Reliable Multicast Protocol (RMP) is implemented on top of IP multicast to facilitate reliable transfer of data for replicated databases and groupware applications that will emerge on the Internet over the next decade. This paper explores some of the basic questions and applications of reliable multicasting in the context of the development and analysis of RMP.
NASA Technical Reports Server (NTRS)
Orr, James K.; Peltier, Daryl
2010-01-01
Thsi slide presentation reviews the avionics software system on board the space shuttle, with particular emphasis on the quality and reliability. The Primary Avionics Software System (PASS) provides automatic and fly-by-wire control of critical shuttle systems which executes in redundant computers. Charts given show the number of space shuttle flights vs time, PASS's development history, and other charts that point to the reliability of the system's development. The reliability of the system is also compared to predicted reliability.
NASA Astrophysics Data System (ADS)
Ebrahimi, Farzad; Barati, Mohammad Reza
2017-12-01
This paper develops a higher order refined beam model with a parabolic shear strain function for vibration analysis of porous nanocrystalline nanobeams based on nonlocal couple stress theory. Nanocrystalline nanobeam is composed from three phases which are nano-grains, nano-voids and interface. Nano-voids or porosities inside the material have a stiffness-softening impact on the nanobeam. Nonlocal elasticity theory of Eringen is applied in analysis of nanocrystalline nanobeams for the first time. Also, modified couple stress theory is employed to capture grains rigid rotations. The governing equations obtained from Hamilton's principle are solved applying an analytical approach which satisfies various boundary conditions. The reliability of present approach is verified by comparing obtained results with those provided in literature. Finally the influences of nonlocal parameter, couple stress, grain size, porosities and shear deformation on the vibration characteristics of nanocrystalline nanobeams are explored.
Surface plasma source with saddle antenna radio frequency plasma generator.
Dudnikov, V; Johnson, R P; Murray, S; Pennisi, T; Piller, C; Santana, M; Stockli, M; Welton, R
2012-02-01
A prototype RF H(-) surface plasma source (SPS) with saddle (SA) RF antenna is developed which will provide better power efficiency for high pulsed and average current, higher brightness with longer lifetime and higher reliability. Several versions of new plasma generators with small AlN discharge chambers and different antennas and magnetic field configurations were tested in the plasma source test stand. A prototype SA SPS was installed in the Spallation Neutron Source (SNS) ion source test stand with a larger, normal-sized SNS AlN chamber that achieved unanalyzed peak currents of up to 67 mA with an apparent efficiency up to 1.6 mA∕kW. Control experiments with H(-) beam produced by SNS SPS with internal and external antennas were conducted. A new version of the RF triggering plasma gun has been designed. A saddle antenna SPS with water cooling is fabricated for high duty factor testing.
A Measure of Team Resilience: Developing the Resilience at Work Team Scale.
McEwen, Kathryn; Boyd, Carolyn M
2018-03-01
This study develops, and initial evaluates, a new measure of team-based resilience for use in research and practice. We conducted preliminary analyses, based on a cross-sectional sample of 344 employees nested within 31 teams. Seven dimensions were identified through exploratory and confirmatory factor analyses. The measure had high reliability and significant discrimination to indicate the presence of a unique team-based aspect of resilience that contributed to higher work engagement and higher self-rated team performance, over and above the effects of individual resilience. Multilevel analyses showed that team, but not individual, resilience predicted self-rated team performance. Practice implications include a need to focus on collective as well as individual behaviors in resilience-building. The measure provides a diagnostic instrument for teams and a scale to evaluate organizational interventions and research the relationship of resilience to other constructs.
Validity of the Family Asthma Management System Scale with an urban African-American sample.
Celano, Marianne; Klinnert, Mary D; Holsey, Chanda Nicole; McQuaid, Elizabeth L
2011-06-01
To examine the reliability and validity of the Family Asthma Management System Scale for low-income African-American children with poor asthma control and caregivers under stress. The FAMSS assesses eight aspects of asthma management from a family systems perspective. Forty-three children, ages 8-13, and caregivers were interviewed with the FAMSS; caregivers completed measures of primary care quality, family functioning, parenting stress, and psychological distress. Children rated their relatedness with the caregiver, and demonstrated inhaler technique. Medical records were reviewed for dates of outpatient visits for asthma. The FAMSS demonstrated good internal consistency. Higher scores were associated with adequate inhaler technique, recent outpatient care, less parenting stress and better family functioning. Higher scores on the Collaborative Relationship with Provider subscale were associated with greater perceived primary care quality. The FAMSS demonstrated relevant associations with asthma management criteria and family functioning for a low-income, African-American sample.
Rolle, Luca; Segade, Susana Río; Torchio, Fabrizio; Giacosa, Simone; Cagnasso, Enzo; Marengo, Fabio; Gerbi, Vincenzo
2011-08-24
Changes in the phenolic composition, phenol extractability indices, and mechanical properties occur in grape berries during the ripening process, but the heterogeneity of the grapes harvested at different ripening stages affects the reliability of the results obtained. In this work, these changes were studied in Nebbiolo grapes harvested during five consecutive weeks and then separated according to three density classes. The changes observed in chemical and mechanical parameters through the ripening process are more related to berry density than harvest date. Therefore, the winemaker has to select the flotation density according to the objective quality properties of the wine to be elaborated. On the other hand, the stiffer grapes were associated with a higher accumulation of proanthocyanidins. The harder grapes provided the higher concentration and extractability of flavanols reactive to vanillin, whereas the thicker ones facilitated the extraction of proanthocyanidins.
Realistic Specific Power Expectations for Advanced Radioisotope Power Systems
NASA Technical Reports Server (NTRS)
Mason, Lee S.
2006-01-01
Radioisotope Power Systems (RPS) are being considered for a wide range of future NASA space science and exploration missions. Generally, RPS offer the advantages of high reliability, long life, and predictable power production regardless of operating environment. Previous RPS, in the form of Radioisotope Thermoelectric Generators (RTG), have been used successfully on many NASA missions including Apollo, Viking, Voyager, and Galileo. NASA is currently evaluating design options for the next generation of RPS. Of particular interest is the use of advanced, higher efficiency power conversion to replace the previous thermoelectric devices. Higher efficiency reduces the quantity of radioisotope fuel and potentially improves the RPS specific power (watts per kilogram). Power conversion options include Segmented Thermoelectric (STE), Stirling, Brayton, and Thermophotovoltaic (TPV). This paper offers an analysis of the advanced 100 watt-class RPS options and provides credible projections for specific power. Based on the analysis presented, RPS specific power values greater than 10 W/kg appear unlikely.
Cameron's Dimensions of Effectiveness in Higher Education in the U.K.: A Cross-Cultural Comparison.
ERIC Educational Resources Information Center
Lysons, Art; Hatherly, David
1992-01-01
An approach to organizational effectiveness in higher education developed in the United States was applied to institutions in the United Kingdom and Australia to establish a basis for policy and organizational analysis. Higher reliability was found for the United Kingdom than for Australia, apparently related to cultural differences regarding…
Evaluation of a Simpler Tool to Assess Nontechnical Skills During Simulated Critical Events.
Watkins, Scott C; Roberts, David A; Boulet, John R; McEvoy, Matthew D; Weinger, Matthew B
2017-04-01
Management of critical events requires teams to employ nontechnical skills (NTS), such as teamwork, communication, decision making, and vigilance. We sought to estimate the reliability and provide evidence for the validity of the ratings gathered using a new tool for assessing the NTS of anesthesia providers, the behaviorally anchored rating scale (BARS), and compare its scores with those of an established NTS tool, the Anaesthetists' Nontechnical Skills (ANTS) scale. Six previously trained raters (4 novices and 2 experts) reviewed and scored 18 recorded simulated pediatric crisis management scenarios using a modified ANTS and a BARS tool. Pearson correlation coefficients were calculated separately for the novice and expert raters, by scenario, and overall. The intrarater reliability of the ANTS total score was 0.73 (expert, 0.57; novice, 0.84); for the BARS tool, it was 0.80 (expert, 0.79; novice, 0.81). The average interrater reliability of BARS scores (0.58) was better than ANTS scores (0.37), and the interrater reliabilities of scores from novices (0.69 BARS and 0.52 ANTS) were better than those obtained from experts (0.47 BARS and 0.21 ANTS) for both scoring instruments. The Pearson correlation between the ANTS and BARS total scores was 0.74. Overall, reliability estimates were better for the BARS scores than the ANTS scores. For both measures, the intrarater and interrater reliability was better for novices compared with domain experts, suggesting that properly trained novices can reliably assess the NTS of anesthesia providers managing a simulated critical event. There was substantial correlation between the 2 scoring instruments, suggesting that the tools measured similar constructs. The BARS tool can be an alternative to the ANTS scale for the formative assessment of NTS of anesthesia providers.
Application of a truncated normal failure distribution in reliability testing
NASA Technical Reports Server (NTRS)
Groves, C., Jr.
1968-01-01
Statistical truncated normal distribution function is applied as a time-to-failure distribution function in equipment reliability estimations. Age-dependent characteristics of the truncated function provide a basis for formulating a system of high-reliability testing that effectively merges statistical, engineering, and cost considerations.
Coefficient Alpha and Reliability of Scale Scores
ERIC Educational Resources Information Center
Almehrizi, Rashid S.
2013-01-01
The majority of large-scale assessments develop various score scales that are either linear or nonlinear transformations of raw scores for better interpretations and uses of assessment results. The current formula for coefficient alpha (a; the commonly used reliability coefficient) only provides internal consistency reliability estimates of raw…
Scoring Rubric Development: Validity and Reliability.
ERIC Educational Resources Information Center
Moskal, Barbara M.; Leydens, Jon A.
2000-01-01
Provides clear definitions of the terms "validity" and "reliability" in the context of developing scoring rubrics and illustrates these definitions through examples. Also clarifies how validity and reliability may be addressed in the development of scoring rubrics, defined as descriptive scoring schemes developed to guide the analysis of the…
Keppler, Hannah; Dhooge, Ingeborg; Maes, Leen; D'haenens, Wendy; Bockstael, Annelies; Philips, Birgit; Swinnen, Freya; Vinck, Bart
2010-02-01
Knowledge regarding the variability of transient-evoked otoacoustic emissions (TEOAEs) and distortion product otoacoustic emissions (DPOAEs) is essential in clinical settings and improves their utility in monitoring hearing status over time. In the current study, TEOAEs and DPOAEs were measured with commercially available OAE-equipment in 56 normally-hearing ears during three sessions. Reliability was analysed for the retest measurement without probe-refitting, the immediate retest measurement with probe-refitting, and retest measurements after one hour and one week. The highest reliability was obtained in the retest measurement without probe-refitting, and decreased with increasing time-interval between measurements. For TEOAEs, the lowest reliability was seen at half-octave frequency bands 1.0 and 1.4 kHz; whereas for DPOAEs half-octave frequency band 8.0 kHz had also poor reliability. Higher primary tone level combination for DPOAEs yielded to a better reliability of DPOAE amplitudes. External environmental noise seemed to be the dominating noise source in normal-hearing subjects, decreasing the reliability of emission amplitudes especially in the low-frequency region.
Reliability in perceptual analysis of voice quality.
Bele, Irene Velsvik
2005-12-01
This study focuses on speaking voice quality in male teachers (n = 35) and male actors (n = 36), who represent untrained and trained voice users, because we wanted to investigate normal and supranormal voices. In this study, both substantial and methodologic aspects were considered. It includes a method for perceptual voice evaluation, and a basic issue was rater reliability. A listening group of 10 listeners, 7 experienced speech-language therapists, and 3 speech-language therapist students evaluated the voices by 15 vocal characteristics using VA scales. Two sets of voice signals were investigated: text reading (2 loudness levels) and sustained vowel (3 levels). The results indicated a high interrater reliability for most perceptual characteristics. Connected speech was evaluated more reliably, especially at the normal level, but both types of voice signals were evaluated reliably, although the reliability for connected speech was somewhat higher than for vowels. Experienced listeners tended to be more consistent in their ratings than did the student raters. Some vocal characteristics achieved acceptable reliability even with a smaller panel of listeners. The perceptual characteristics grouped in 4 factors reflected perceptual dimensions.
NASA Astrophysics Data System (ADS)
Lam, C. Y.; Ip, W. H.
2012-11-01
A higher degree of reliability in the collaborative network can increase the competitiveness and performance of an entire supply chain. As supply chain networks grow more complex, the consequences of unreliable behaviour become increasingly severe in terms of cost, effort and time. Moreover, it is computationally difficult to calculate the network reliability of a Non-deterministic Polynomial-time hard (NP-hard) all-terminal network using state enumeration, as this may require a huge number of iterations for topology optimisation. Therefore, this paper proposes an alternative approach of an improved spanning tree for reliability analysis to help effectively evaluate and analyse the reliability of collaborative networks in supply chains and reduce the comparative computational complexity of algorithms. Set theory is employed to evaluate and model the all-terminal reliability of the improved spanning tree algorithm and present a case study of a supply chain used in lamp production to illustrate the application of the proposed approach.
Multi-hop routing mechanism for reliable sensor computing.
Chen, Jiann-Liang; Ma, Yi-Wei; Lai, Chia-Ping; Hu, Chia-Cheng; Huang, Yueh-Min
2009-01-01
Current research on routing in wireless sensor computing concentrates on increasing the service lifetime, enabling scalability for large number of sensors and supporting fault tolerance for battery exhaustion and broken nodes. A sensor node is naturally exposed to various sources of unreliable communication channels and node failures. Sensor nodes have many failure modes, and each failure degrades the network performance. This work develops a novel mechanism, called Reliable Routing Mechanism (RRM), based on a hybrid cluster-based routing protocol to specify the best reliable routing path for sensor computing. Table-driven intra-cluster routing and on-demand inter-cluster routing are combined by changing the relationship between clusters for sensor computing. Applying a reliable routing mechanism in sensor computing can improve routing reliability, maintain low packet loss, minimize management overhead and save energy consumption. Simulation results indicate that the reliability of the proposed RRM mechanism is around 25% higher than that of the Dynamic Source Routing (DSR) and ad hoc On-demand Distance Vector routing (AODV) mechanisms.
Newly developed double neural network concept for reliable fast plasma position control
NASA Astrophysics Data System (ADS)
Jeon, Young-Mu; Na, Yong-Su; Kim, Myung-Rak; Hwang, Y. S.
2001-01-01
Neural network is considered as a parameter estimation tool in plasma controls for next generation tokamak such as ITER. The neural network has been reported to be so accurate and fast for plasma equilibrium identification that it may be applied to the control of complex tokamak plasmas. For this application, the reliability of the conventional neural network needs to be improved. In this study, a new idea of double neural network is developed to achieve this. The new idea has been applied to simple plasma position identification of KSTAR tokamak for feasibility test. Characteristics of the concept show higher reliability and fault tolerance even in severe faulty conditions, which may make neural network applicable to plasma control reliably and widely in future tokamaks.
Operating room clinicians' ratings of workload: a vignette simulation study.
Wallston, Kenneth A; Slagle, Jason M; Speroff, Ted; Nwosu, Sam; Crimin, Kimberly; Feurer, Irene D; Boettcher, Brent; Weinger, Matthew B
2014-06-01
Increased clinician workload is associated with medical errors and patient harm. The Quality and Workload Assessment Tool (QWAT) measures anticipated (pre-case) and perceived (post-case) clinical workload during actual surgical procedures using ratings of individual and team case difficulty from every operating room (OR) team member. The purpose of this study was to examine the QWAT ratings of OR clinicians who were not present in the OR but who read vignettes compiled from actual case documentation to assess interrater reliability and agreement with ratings made by clinicians involved in the actual cases. Thirty-six OR clinicians (13 anesthesia providers, 11 surgeons, and 12 nurses) used the QWAT to rate 6 cases varying from easy to moderately difficult based on actual ratings made by clinicians involved with the cases. Cases were presented and rated in random order. Before rating anticipated individual and team difficulty, the raters read prepared clinical vignettes containing case synopses and much of the same written case information that was available to the actual clinicians before the onset of each case. Then, before rating perceived individual and team difficulty, they read part 2 of the vignette consisting of detailed role-specific intraoperative data regarding the anesthetic and surgical course, unusual events, and other relevant contextual factors. Surgeons had higher interrater reliability on the QWAT than did OR nurses or anesthesia providers. For the anticipated individual and team workload ratings, there were no statistically significant differences between the actual ratings and the ratings obtained from the vignettes. There were differences for the 3 provider types in perceived individual workload for the median difficulty cases and in the perceived team workload for the median and more difficult cases. The case difficulty items on the QWAT seem to be sufficiently reliable and valid to be used in other studies of anticipated and perceived clinical workload of surgeons. Perhaps because of the limitations of the clinical documentation shown to anesthesia providers and OR nurses in the current vignette study, more evidence needs to be gathered to demonstrate the criterion-related validity of the QWAT difficulty items for assessing the workload of nonsurgeon OR clinicians.
O'Connor, S; McCaffrey, N; Whyte, E; Moran, K
2016-07-01
To adapt the trunk stability test to facilitate further sub-classification of higher levels of core stability in athletes for use as a screening tool. To establish the inter-tester and intra-tester reliability of this adapted core stability test. Reliability study. Collegiate athletic therapy facilities. Fifteen physically active male subjects (19.46 ± 0.63) free from any orthopaedic or neurological disorders were recruited from a convenience sample of collegiate students. The intraclass correlation coefficients (ICC) and 95% Confidence Intervals (CI) were computed to establish inter-tester and intra-tester reliability. Excellent ICC values were observed in the adapted core stability test for inter-tester reliability (0.97) and good to excellent intra-tester reliability (0.73-0.90). While the 95% CI were narrow for inter-tester reliability, Tester A and C 95% CI's were widely distributed compared to Tester B. The adapted core stability test developed in this study is a quick and simple field based test to administer that can further subdivide athletes with high levels of core stability. The test demonstrated high inter-tester and intra-tester reliability. Copyright © 2015 Elsevier Ltd. All rights reserved.
Skinner, Ian W; Hübscher, Markus; Moseley, G Lorimer; Lee, Hopin; Wand, Benedict M; Traeger, Adrian C; Gustin, Sylvia M; McAuley, James H
2017-08-15
Eyetracking is commonly used to investigate attentional bias. Although some studies have investigated the internal consistency of eyetracking, data are scarce on the test-retest reliability and agreement of eyetracking to investigate attentional bias. This study reports the test-retest reliability, measurement error, and internal consistency of 12 commonly used outcome measures thought to reflect the different components of attentional bias: overall attention, early attention, and late attention. Healthy participants completed a preferential-looking eyetracking task that involved the presentation of threatening (sensory words, general threat words, and affective words) and nonthreatening words. We used intraclass correlation coefficients (ICCs) to measure test-retest reliability (ICC > .70 indicates adequate reliability). The ICCs(2, 1) ranged from -.31 to .71. Reliability varied according to the outcome measure and threat word category. Sensory words had a lower mean ICC (.08) than either affective words (.32) or general threat words (.29). A longer exposure time was associated with higher test-retest reliability. All of the outcome measures, except second-run dwell time, demonstrated low measurement error (<6%). Most of the outcome measures reported high internal consistency (α > .93). Recommendations are discussed for improving the reliability of eyetracking tasks in future research.
The Pieper-Zulkowski pressure ulcer knowledge test.
Pieper, Barbara; Zulkowski, Karen
2014-09-01
To describe the development and initial testing of the Pieper-Zulkowski Pressure Ulcer Knowledge Test (PZ-PUKT). Cross-sectional, instrument testing. Hospital association pressure ulcer educational program conference. Pressure ulcer research and guidelines from the last 5 years were examined for test item content. The initial PZ-PUKT had 115 items; response options were "true," "false," and "don't know." Registered nurses (N = 108) were randomly divided into 2 groups to take either the 60 prevention/risk and staging items or the 55 wound description items. Analyses of these responses resulted in 72 items, which were administered in total to a second cohort of 98 nurses for reliability. Cronbach's α was .80 for the 72-item PZ-PUKT. Cronbach's α values for the subscales were as follows: staging, .67; wound description, .64; and prevention/risk, .56. The mean correct scores were as follows: total, 80%; prevention, 77%; staging, 86%; and wound description, 77%. Nurses with wound care certification scored significantly higher on the PZ-PUKT than did nurses with other clinical certifications or with nurses who lacked certification. The PZ-PUKT has updated content about pressure ulcer prevention/risk, staging, and wound description. Reliability values are highest for the total test. Further use of the instrument in diverse settings will add to reliability testing and may provide direction for determination of a passing cutoff score.
Negoita, Madalina; Zolgharni, Massoud; Dadkho, Elham; Pernigo, Matteo; Mielewczik, Michael; Cole, Graham D; Dhutia, Niti M; Francis, Darrel P
2016-09-01
To determine the optimal frame rate at which reliable heart walls velocities can be assessed by speckle tracking. Assessing left ventricular function with speckle tracking is useful in patient diagnosis but requires a temporal resolution that can follow myocardial motion. In this study we investigated the effect of different frame rates on the accuracy of speckle tracking results, highlighting the temporal resolution where reliable results can be obtained. 27 patients were scanned at two different frame rates at their resting heart rate. From all acquired loops, lower temporal resolution image sequences were generated by dropping frames, decreasing the frame rate by up to 10-fold. Tissue velocities were estimated by automated speckle tracking. Above 40 frames/s the peak velocity was reliably measured. When frame rate was lower, the inter-frame interval containing the instant of highest velocity also contained lower velocities, and therefore the average velocity in that interval was an underestimate of the clinically desired instantaneous maximum velocity. The higher the frame rate, the more accurately maximum velocities are identified by speckle tracking, until the frame rate drops below 40 frames/s, beyond which there is little increase in peak velocity. We provide in an online supplement the vendor-independent software we used for automatic speckle-tracked velocity assessment to help others working in this field. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
MacDonald, Sheila
2016-01-01
Childhood acquired brain injuries can disrupt communication functions needed for success in school, work and social interaction. Cognitive-communication difficulties may not be apparent until adolescence, when academic, environmental and social-emotional demands increase. The Functional Assessment of Verbal Reasoning and Executive Strategies for Students (S-FAVRES) is a new activity-level measure of cognitive-communication skills in complex, contextual and integrative tasks that simulate real world communication challenges. It is hypothesized that S-FAVRES performance would differentiate adolescents with and without acquired brain injury (ABI) on scores for Accuracy, Rationale, Reasoning Subskills and Time. S-FAVRES was administered to 182 typically-developing (TD) and 57 adolescents with mild-to-severe ABI aged 12-19. Group differences, internal consistency, sensitivity, specificity, reliability and contributing factors to performance (age, gender, brain injury) were examined statistically. Those with ABI attained statistically lower Accuracy, Rationale and Reasoning sub-skills scores than their TD peers. Time scores were not significantly different. Performance trends were consistent across tasks, administrations, gender and age groups. Inter-rater reliability for scoring was acceptable. The S-FAVRES provides a reliable, functional and quantifiable measure of subtle cognitive-communication difficulties in adolescents that can assist speech-language pathologists in planning treatment and integration to school and real world communication.
Reliability and Validity of the Physical Education Activities Scale.
Thomason, Diane L; Feng, Du
2016-06-01
Measuring adolescent perceptions of physical education (PE) activities is necessary in understanding determinants of school PE activity participation. This study assessed reliability and validity of the Physical Education Activities Scale (PEAS), a 41-item visual analog scale measuring high school adolescent perceptions of school PE activity participation. Adolescents (N = 529) from the Pacific Northwest aged 15-19 in grades 9-12 participated in the study. Construct validity was assessed using exploratory factor analysis (EFA) and confirmatory factor analysis (CFA). Measurement invariance across sex groups was tested by multiple-group CFA. Internal consistency reliability was analyzed using Cronbach's alpha. Inter-subscale correlations (Pearson's r) were calculated for latent factors and observed subscale scores. Exploratory factor analysis suggested a 3-factor solution explaining 43.4% of the total variance. Confirmatory factor analysis showed the 3-factor model fit the data adequately (comparative fit index [CFI] = 0.90, Tucker-Lewis index [TLI] = 0.89, root mean squared error of approximation [RMSEA] = 0.063). Factorial invariance was supported. Cronbach's alpha of the total PEAS was α = 0.92, and for subscales α ranged from 0.65 to 0.92. Independent t-tests showed significantly higher mean scores for boys than girls on the total scale and all subscales. Findings provide psychometric support for using the PEAS for examining adolescent's psychosocial and environmental perceptions to participating in PE activities. © 2016, American School Health Association.
Evaluation of the Cardiac Depression Visual Analogue Scale in a medical and non-medical sample.
Di Benedetto, Mirella; Sheehan, Matthew
2014-01-01
Comorbid depression and medical illness is associated with a number of adverse health outcomes such as lower medication adherence and higher rates of subsequent mortality. Reliable and valid psychological measures capable of detecting a range of depressive symptoms found in medical settings are needed. The Cardiac Depression Visual Analogue Scale (CDVAS) is a recently developed, brief six-item measure originally designed to assess the range and severity of depressive symptoms within a cardiac population. The current study aimed to further investigate the psychometric properties of the CDVAS in a general and medical sample. The sample consisted of 117 participants, whose mean age was 40.0 years (SD = 19.0, range 18-84). Participants completed the CDVAS, the Cardiac Depression Scale (CDS), the Depression Anxiety Stress Scales (DASS) and a demographic and health questionnaire. The CDVAS was found to have adequate internal reliability (α = .76), strong concurrent validity with the CDS (r = .89) and the depression sub-scale of the DASS (r = .70), strong discriminant validity and strong predictive validity. The principal components analysis revealed that the CDVAS measured only one component, providing further support for the construct validity of the scale. Results of the current study indicate that the CDVAS is a short, simple, valid and reliable measure of depressive symptoms suitable for use in a general and medical sample.
Maroufizadeh, Saman; Zareiyan, Armin; Sigari, Naseh
2014-05-01
Asthma is a major public health problem in the world, and recent findings suggest that stress influences asthma and asthma morbidity. The 10-item Perceived Stress Scale (PSS-10) is one of the most frequently used instruments to measure psychological stress. This study was conducted to evaluate the psychometric properties of the Persian versions of the PSS-10 in adults with asthma. In this descriptive cross-sectional study as a methodological research, 106 asthmatic patients referring to several clinics in Sanandaj (western Iran) were selected through convenience sampling. The PSS-10 and the 21-item Depression anxiety and stress scale (DASS-21) were administrated to all patients. Cronbach's alpha was used to evaluate reliability of PSS-10, and confirmatory factor analysis (CFA) and convergent validity were used to evaluate its validity. The results of confirmatory factor analysis indicated that a two-factor structure of PSS-10 provided a good fit to data. The Cronbach's alpha coefficients for negative factor, positive factor and total score (PSS-10) were 0.86, 0.83, and 0.90, respectively. The PSS-10 was positively correlated with the DASS-21 and its subscales, indicating an acceptable convergent validity. Female asthmatic patients scored higher on PSS-10 in comparison with male asthmatic patients. The Persian version of PSS-10 is a valid and reliable instrument to measure perceived stress in adults with asthma.
Expressed emotion in children: associations with sibling relationships.
Yelland, I; Daley, D
2009-07-01
To investigate the reliability and validity of the expressed emotion (EE) measure, the Pre-school Five Minute Speech Sample (PFMSS), in child-to-child sibling relationships. A total of 106 boys aged 7-11 were recruited from 12 mainstream primary schools in North Wales. The children completed the PFMSS regarding their sibling and two self-report measures of sibling relationship: the Sibling Relationship Questionnaire (SRQ) and a Child Visual Analogue Scale (CVAS). The parents of 60 participants completed the Strengths and Difficulties Questionnaire regarding the behavioural problems of the participating child and his younger sibling. The PFMSS demonstrated good inter-rater and code-recode reliability. The significant associations between EE dimensions such as relationship, positive comments and critical comments with various components of the SRQ and CVAS provided support for the concurrent validity of the PFMSS. Significantly higher levels of Conflict and Rivalry and significantly lower levels of Warmth/Closeness on the SRQ were reported by children with high EE, demonstrating good discriminant validity for the PFMSS. There was no significant association between the child's EE profile and the behavioural difficulties of both siblings as reported by parents. The study found that the PFMSS is a valid and reliable measure of child EE. Future research is needed to clarify the concurrent validity of the warmth and initial statement components of the measure as well as the association between EE dimensions and behaviour.
Forensic evaluation of STR typing reliability in lung cancer.
Zhang, Peng; Zhu, Ying; Li, Yongguo; Zhu, Shisheng; Ma, Ruoxiang; Zhao, Minzhu; Li, Jianbo
2018-01-01
Short tandem repeats (STR) analysis is the gold standard method in the forensics field for personal identification and paternity testing. In cancerous tissues, STR markers are gaining attention, with some studies showing increased instability. Lung cancer, which is one of the most commonmalignancies, has become the most lethal among all cancers. In certain situations, lung cancer tissues may be the only resource available for forensic analysis. Therefore, evaluating the reliability of STR markers in lung cancer tissues is required to avoid false exclusions. In this study, 75 lung cancer tissue samples were examined to evaluate the reliability of various STR markers. Out of the 75 examined samples, 24 of the cancerous samples (32%) showed genetic alterations on at least one STR loci, totaling 55 times. The most common type of STR variation was a partial loss of heterozygosity, with the D5S818 loci having the highest variation frequency and no alterations detected on the D2S441 and Penta E loci. Moreover, STR variation frequencies were shown to increase with an increased patient age and increased clinical and pathological characteristics, thus an older patient with an advanced stage of progression exhibited a higher variation frequency. Overall, this study provides forensic scientists with further insight into STR analysis relating to lung cancer tissue. Copyright © 2017 Elsevier B.V. All rights reserved.
Feasibility and fidelity of practising surgical fixation on a virtual ulna bone
LeBlanc, Justin; Hutchison, Carol; Hu, Yaoping; Donnon, Tyrone
2013-01-01
Background Surgical simulators provide a safe environment to learn and practise psychomotor skills. A goal for these simulators is to achieve high levels of fidelity. The purpose of this study was to develop a reliable surgical simulator fidelity questionnaire and to assess whether a newly developed virtual haptic simulator for fixation of an ulna has comparable levels of fidelity as Sawbones. Methods Simulator fidelity questionnaires were developed. We performed a stratified randomized study with surgical trainees. They performed fixation of the ulna using a virtual simulator and Sawbones. They completed the fidelity questionnaires after each procedure. Results Twenty-two trainees participated in the study. The reliability of the fidelity questionnaire for each separate domain (environment, equipment, psychological) was Cronbach α greater than 0.70, except for virtual environment. The Sawbones had significantly higher levels of fidelity than the virtual simulator (p < 0.001) with a large effect size difference (Cohen d < 1.3). Conclusion The newly developed fidelity questionnaire is a reliable tool that can potentially be used to determine the fidelity of other surgical simulators. Increasing the fidelity of this virtual simulator is required before its use as a training tool for surgical fixation. The virtual simulator brings with it the added benefits of repeated, independent safe use with immediate, objective feedback and the potential to alter the complexity of the skill. PMID:23883510
Advanced Reactor PSA Methodologies for System Reliability Analysis and Source Term Assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grabaskas, D.; Brunett, A.; Passerini, S.
Beginning in 2015, a project was initiated to update and modernize the probabilistic safety assessment (PSA) of the GE-Hitachi PRISM sodium fast reactor. This project is a collaboration between GE-Hitachi and Argonne National Laboratory (Argonne), and funded in part by the U.S. Department of Energy. Specifically, the role of Argonne is to assess the reliability of passive safety systems, complete a mechanistic source term calculation, and provide component reliability estimates. The assessment of passive system reliability focused on the performance of the Reactor Vessel Auxiliary Cooling System (RVACS) and the inherent reactivity feedback mechanisms of the metal fuel core. Themore » mechanistic source term assessment attempted to provide a sequence specific source term evaluation to quantify offsite consequences. Lastly, the reliability assessment focused on components specific to the sodium fast reactor, including electromagnetic pumps, intermediate heat exchangers, the steam generator, and sodium valves and piping.« less
Meta-analytic guidelines for evaluating single-item reliabilities of personality instruments.
Spörrle, Matthias; Bekk, Magdalena
2014-06-01
Personality is an important predictor of various outcomes in many social science disciplines. However, when personality traits are not the principal focus of research, for example, in global comparative surveys, it is often not possible to assess them extensively. In this article, we first provide an overview of the advantages and challenges of single-item measures of personality, a rationale for their construction, and a summary of alternative ways of assessing their reliability. Second, using seven diverse samples (Ntotal = 4,263) we develop the SIMP-G, the German adaptation of the Single-Item Measures of Personality, an instrument assessing the Big Five with one item per trait, and evaluate its validity and reliability. Third, we integrate previous research and our data into a first meta-analysis of single-item reliabilities of personality measures, and provide researchers with guidelines and recommendations for the evaluation of single-item reliabilities. © The Author(s) 2013.
HASH: the Hong Kong/AAO/Strasbourg Hα planetary nebula database
NASA Astrophysics Data System (ADS)
Parker, Quentin A.; Bojičić, Ivan S.; Frew, David J.
2016-07-01
By incorporating our major recent discoveries with re-measured and verified contents of existing catalogues we provide, for the first time, an accessible, reliable, on-line SQL database for essential, up-to date information for all known Galactic planetary nebulae (PNe). We have attempted to: i) reliably remove PN mimics/false ID's that have biased previous studies and ii) provide accurate positions, sizes, morphologies, multi-wavelength imagery and spectroscopy. We also provide a link to CDS/Vizier for the archival history of each object and other valuable links to external data. With the HASH interface, users can sift, select, browse, collate, investigate, download and visualise the entire currently known Galactic PNe diversity. HASH provides the community with the most complete and reliable data with which to undertake new science.
Which symptom assessments and approaches are uniquely appropriate for paediatric concussion?
Gioia, G A; Schneider, J C; Vaughan, C G; Isquith, P K
2009-05-01
To (a) identify post-concussion symptom scales appropriate for children and adolescents in sports; (b) review evidence for reliability and validity; and (c) recommend future directions for scale development. Quantitative and qualitative literature review of symptom rating scales appropriate for children and adolescents aged 5 to 22 years. Literature identified via search of Medline, Ovid-Medline and PsycInfo databases; review of reference lists in identified articles; querying sports concussion specialists. 29 articles met study inclusion criteria. 5 symptom scales examined in 11 studies for ages 5-12 years and in 25 studies for ages 13-22. 10 of 11 studies for 5-12-year-olds presented validity evidence for three scales; 7 studies provided reliability evidence for two scales; 7 studies used serial administrations but no reliable change metrics. Two scales included parent-reports and one included a teacher report. 24 of 25 studies for 13-22 year-olds presented validity evidence for five measures; seven studies provided reliability evidence for four measures with 18 studies including serial administrations and two examining Reliable Change. Psychometric evidence for symptom scales is stronger for adolescents than for younger children. Most scales provide evidence of concurrent validity, discriminating concussed and non-concussed groups. Few report reliability and evidence for validity is narrow. Two measures include parent/teacher reports. Few scales examine reliable change statistics, limiting interpretability of temporal changes. Future studies are needed to fully define symptom scale psychometric properties with the greatest need in younger student-athletes.
Demonstration of Essential Reliability Services by Utility-Scale Solar
Essential Reliability Services by Utility-Scale Solar Photovoltaic Power Plant: Q&A Demonstration of Essential Reliability Services by Utility-Scale Solar Photovoltaic Power Plant: Q&A Webinar Questions & Answers April 27, 2017 Is photovoltaic (PV) generation required to provide grid supportive
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-13
...] Food and Drug Administration/American Glaucoma Society Workshop on the Validity, Reliability, and... entitled ``FDA/American Glaucoma Society (AGS) Workshop on the Validity, Reliability, and Usability of... research. The purpose of this public workshop is to provide a forum for discussing the validity...
Evaluation of Validity and Reliability for Hierarchical Scales Using Latent Variable Modeling
ERIC Educational Resources Information Center
Raykov, Tenko; Marcoulides, George A.
2012-01-01
A latent variable modeling method is outlined, which accomplishes estimation of criterion validity and reliability for a multicomponent measuring instrument with hierarchical structure. The approach provides point and interval estimates for the scale criterion validity and reliability coefficients, and can also be used for testing composite or…