Hematological reference values of healthy Malaysian population.
Roshan, T M; Rosline, H; Ahmed, S A; Rapiaah, M; Wan Zaidah, A; Khattak, M N
2009-10-01
Health and disease can only be distinguished by accurate and reliable reference values of a particular laboratory test. It is now a proven fact that there is considerable variation in hematology reference intervals depending on the demographic and preanalytical variables. There are evidences that values provided by manufacturers do not have appropriate application for all populations. Moreover, reference ranges provided by different laboratory manuals and books also do not solve this problem. We are presenting here normal reference ranges of Malaysian population. These values were determined by using Sysmex XE-2100 and ACL 9000 hematology and coagulation analyzers. Results from this study showed that there were considerable differences in the reference values from manufacturers, western population or laboratory manuals compared with those from the local population.
2002-01-01
This report presents detailed information on age- and gender-related differences in the anatomical and physiological characteristics of reference individuals. These reference values provide needed input to prospective dosimetry calculations for radiation protection purposes for both workers and members of the general public. The purpose of this report is to consolidate and unify in one publication, important new information on reference anatomical and physiological values that has become available since Publication 23 was published by the ICRP in 1975. There are two aspects of this work. The first is to revise and extend the information in Publication 23 as appropriate. The second is to provide additional information on individual variation among grossly normal individuals resulting from differences in age, gender, race, or other factors. This publication collects, unifies, and expands the updated ICRP reference values for the purpose of providing a comprehensive and consistent set of age- and gender-specific reference values for anatomical and physiological features of the human body pertinent to radiation dosimetry. The reference values given in this report are based on: (a) anatomical and physiological information not published before by the ICRP; (b) recent ICRP publications containing reference value information; and (c) information in Publication 23 that is still considered valid and appropriate for radiation protection purposes. Moving from the past emphasis on 'Reference Man', the new report presents a series of reference values for both male and female subjects of six different ages: newborn, 1 year, 5 years, 10 years, 15 years, and adult. In selecting reference values, the Commission has used data on Western Europeans and North Americans because these populations have been well studied with respect to antomy, body composition, and physiology. When appropriate, comparisons are made between the chosen reference values and data from several Asian populations. The first section of the report provides summary tables of all the anatomical and physiological parameters given as reference values in this publication. These results give a comprehensive view of reference values for an individual as influenced by age and gender. The second section describes characteristics of dosimetric importance for the embryo and fetus. Information is provided on the development of the total body and the timing of appearance and development of the various organ systems. Reference values are provided on the mass of the total body and selected organs and tissues, as well as a number of physiological parameters. The third section deals with reference values of important anatomical and physiological characteristics of reference individuals from birth to adulthood. This section begins with details on the growth and composition of the total body in males and females. It then describes and quantifies anatomical and physiological characteristics of various organ systems and changes in these characteristics during growth, maturity, and pregnancy. Reference values are specified for characteristics of dosimetric importance. The final section gives a brief summary of the elemental composition of individuals. Focusing on the elements of dosimetric importance, information is presented on the body content of 13 elements: calcium, carbon, chloride, hydrogen, iodine, iron, magnesium, nitrogen, oxygen, potassium, sodium, sulphur, and phosphorus.
The conventional tuning fork as a quantitative tool for vibration threshold.
Alanazy, Mohammed H; Alfurayh, Nuha A; Almweisheer, Shaza N; Aljafen, Bandar N; Muayqil, Taim
2018-01-01
This study was undertaken to describe a method for quantifying vibration when using a conventional tuning fork (CTF) in comparison to a Rydel-Seiffer tuning fork (RSTF) and to provide reference values. Vibration thresholds at index finger and big toe were obtained in 281 participants. Spearman's correlations were performed. Age, weight, and height were analyzed for their covariate effects on vibration threshold. Reference values at the fifth percentile were obtained by quantile regression. The correlation coefficients between CTF and RSTF values at finger/toe were 0.59/0.64 (P = 0.001 for both). Among covariates, only age had a significant effect on vibration threshold. Reference values for CTF at finger/toe for the age groups 20-39 and 40-60 years were 7.4/4.9 and 5.8/4.6 s, respectively. Reference values for RSTF at finger/toe for the age groups 20-39 and 40-60 years were 6.9/5.5 and 6.2/4.7, respectively. CTF provides quantitative values that are as good as those provided by RSTF. Age-stratified reference data are provided. Muscle Nerve 57: 49-53, 2018. © 2017 Wiley Periodicals, Inc.
Conversion of ICRP male reference phantom to polygon-surface phantom
NASA Astrophysics Data System (ADS)
Yeom, Yeon Soo; Han, Min Cheol; Kim, Chan Hyeong; Jeong, Jong Hwi
2013-10-01
The International Commission on Radiological Protection (ICRP) reference phantoms, developed based on computed tomography images of human bodies, provide much more realism of human anatomy than the previously used MIRD5 (Medical Internal Radiation Dose) mathematical phantoms. It has been, however, realized that the ICRP reference phantoms have some critical limitations showing a considerable amount of holes for the skin and wall organs mainly due to the nature of voxels of which the phantoms are made, especially due to their low voxel resolutions. To address this problem, we are planning to develop the polygon-surface version of ICRP reference phantoms by directly converting the ICRP reference phantoms (voxel phantoms) to polygon-surface phantoms. The objective of this preliminary study is to see if it is indeed possible to construct the high-quality polygon-surface phantoms based on the ICRP reference phantoms maintaining identical organ morphology and also to identify any potential issues, and technologies to address these issues, in advance. For this purpose, in the present study, the ICRP reference male phantom was roughly converted to a polygon-surface phantom. Then, the constructed phantom was implemented in Geant4, Monte Carlo particle transport code, for dose calculations, and the calculated dose values were compared with those of the original ICRP reference phantom to see how much the calculated dose values are sensitive to the accuracy of the conversion process. The results of the present study show that it is certainly possible to convert the ICRP reference phantoms to surface phantoms with enough accuracy. In spite of using relatively less resources (<2 man-months), we were able to construct the polygon-surface phantom with the organ masses perfectly matching the ICRP reference values. The analysis of the calculated dose values also implies that the dose values are indeed not very sensitive to the detailed morphology of the organ models in the phantom for highly penetrating radiations such as photons and neutrons. The results of the electron beams, on the other hand, show that the dose values of the polygon-surface phantom are higher by a factor of 2-5 times than those of the ICRP reference phantom for the skin and wall organs which have large holes due to low voxel resolution. The results demonstrate that the ICRP reference phantom could provide significantly unreasonable dose values to thin or wall organs especially for weakly penetrating radiations. Therefore, when compared to the original ICRP reference phantoms, it is believed that the polygon-surface version of ICRP reference phantoms properly developed will not only provide the same or similar dose values (say, difference <5 or 10%) for highly penetrating radiations, but also provide correct dose values for the weakly penetrating radiations such as electrons and other charged particles.
Geffré, Anne; Concordet, Didier; Braun, Jean-Pierre; Trumel, Catherine
2011-03-01
International recommendations for determination of reference intervals have been recently updated, especially for small reference sample groups, and use of the robust method and Box-Cox transformation is now recommended. Unfortunately, these methods are not included in most software programs used for data analysis by clinical laboratories. We have created a set of macroinstructions, named Reference Value Advisor, for use in Microsoft Excel to calculate reference limits applying different methods. For any series of data, Reference Value Advisor calculates reference limits (with 90% confidence intervals [CI]) using a nonparametric method when n≥40 and by parametric and robust methods from native and Box-Cox transformed values; tests normality of distributions using the Anderson-Darling test and outliers using Tukey and Dixon-Reed tests; displays the distribution of values in dot plots and histograms and constructs Q-Q plots for visual inspection of normality; and provides minimal guidelines in the form of comments based on international recommendations. The critical steps in determination of reference intervals are correct selection of as many reference individuals as possible and analysis of specimens in controlled preanalytical and analytical conditions. Computing tools cannot compensate for flaws in selection and size of the reference sample group and handling and analysis of samples. However, if those steps are performed properly, Reference Value Advisor, available as freeware at http://www.biostat.envt.fr/spip/spip.php?article63, permits rapid assessment and comparison of results calculated using different methods, including currently unavailable methods. This allows for selection of the most appropriate method, especially as the program provides the CI of limits. It should be useful in veterinary clinical pathology when only small reference sample groups are available. ©2011 American Society for Veterinary Clinical Pathology.
[Geographical distribution of the Serum creatinine reference values of healthy adults].
Wei, De-Zhi; Ge, Miao; Wang, Cong-Xia; Lin, Qian-Yi; Li, Meng-Jiao; Li, Peng
2016-11-20
To explore the relationship between serum creatinine (Scr) reference values in healthy adults and geographic factors and provide evidence for establishing Scr reference values in different regions. We collected 29 697 Scr reference values from healthy adults measured by 347 medical facilities from 23 provinces, 4 municipalities and 5 autonomous regions. We chose 23 geographical factors and analyzed their correlation with Scr reference values to identify the factors correlated significantly with Scr reference values. According to the Principal component analysis and Ridge regression analysis, two predictive models were constructed and the optimal model was chosen after comparison of the two model's fitting degree of predicted results and measured results. The distribution map of Scr reference values was drawn using the Kriging interpolation method. Seven geographic factors, including latitude, annual sunshine duration, annual average temperature, annual average relative humidity, annual precipitation, annual temperature range and topsoil (silt) cation exchange capacity were found to correlate significantly with Scr reference values. The overall distribution of Scr reference values featured a pattern that the values were high in the south and low in the north, varying consistently with the latitude change. The data of the geographic factors in a given region allows the prediction of the Scr values in healthy adults. Analysis of these geographical factors can facilitate the determination of the reference values specific to a region to improve the accuracy for clinical diagnoses.
WILDLIFE TOXICITY REFERENCE VALUES FOR POLYNUCLEAR AROMATIC HYDROCARBONS AND DDT
The presentation will provide an overview of the procedures used in deriving mammalian and avian wildlife toxicity reference values to be used in development of ecological soil screening levels (Eco-SSLs).
Value of Information References
Morency, Christina
2014-12-12
This file contains a list of relevant references on value of information (VOI) in RIS format. VOI provides a quantitative analysis to evaluate the outcome of the combined technologies (seismology, hydrology, geodesy) used to monitor Brady's Geothermal Field.
Makretsov, Nikita; Gilks, C Blake; Alaghehbandan, Reza; Garratt, John; Quenneville, Louise; Mercer, Joel; Palavdzic, Dragana; Torlakovic, Emina E
2011-07-01
External quality assurance and proficiency testing programs for breast cancer predictive biomarkers are based largely on traditional ad hoc design; at present there is no universal consensus on definition of a standard reference value for samples used in external quality assurance programs. To explore reference values for estrogen receptor and progesterone receptor immunohistochemistry in order to develop an evidence-based analytic platform for external quality assurance. There were 31 participating laboratories, 4 of which were previously designated as "expert" laboratories. Each participant tested a tissue microarray slide with 44 breast carcinomas for estrogen receptor and progesterone receptor and submitted it to the Canadian Immunohistochemistry Quality Control Program for analysis. Nuclear staining in 1% or more of the tumor cells was a positive score. Five methods for determining reference values were compared. All reference values showed 100% agreement for estrogen receptor and progesterone receptor scores, when indeterminate results were excluded. Individual laboratory performance (agreement rates, test sensitivity, test specificity, positive predictive value, negative predictive value, and κ value) was very similar for all reference values. Identification of suboptimal performance by all methods was identical for 30 of 31 laboratories. Estrogen receptor assessment of 1 laboratory was discordant: agreement was less than 90% for 3 of 5 reference values and greater than 90% with the use of 2 other reference values. Various reference values provide equivalent laboratory rating. In addition to descriptive feedback, our approach allows calculation of technical test sensitivity and specificity, positive and negative predictive values, agreement rates, and κ values to guide corrective actions.
Korean anatomical reference data for adults for use in radiological protection
NASA Astrophysics Data System (ADS)
Choi, Chansoo; Yeom, Yeon Soo; Nguyen, Thang Tat; Lee, Hanjin; Han, Haegin; Shin, Bangho; Zhang, Xujia; Kim, Chan Hyeong; Chung, Beom Sun
2018-01-01
For radiological protection from exposure to ionizing radiation, in which a population-averaged dose evaluation is used, establishing a system of reference anatomical and physiological data for a specific population of interest is important. Some studies were done in the past to establish Korean reference data; however, the data provided the mass values only for a limited number of organs/tissues. In addition, the standing height and total body mass are based on 20-year-old data. In the present study, a new set of Korean reference anatomical values was established for use in the radiological protection of Korean workers and members of the public. The established Korean reference data provide the masses of 58 organs/tissues, including those needed to calculate the effective dose, which were derived by collecting and analyzing various scientific reports in the literature and data. In addition, the data provide not only standing height and total body mass, but also 131 additional anthropometric parameters; these values were derived from the most recent Korean national survey project, 7 th Size Korea. The characteristics of the data were also compared with several other population data, including the Asian and the International Commission on Radiological Protection (ICRP) reference data.
Qi, Haiping; Lorenz, Jennifer M.; Coplen, Tyler B.; Tarbox, Lauren V.; Mayer, Bernhard; Taylor, Steve
2014-01-01
RESULTS: The δ2H and δ18O values of this reference water are –150.2 ± 0.5 ‰ and –19.80 ± 0.02 ‰, respectively, relative to VSMOW on scales normalized such that the δ2H and δ18O values of SLAP reference water are, respectively, –428 and –55.5 ‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95-percent probability of encompassing the true value. CONCLUSION: This isotopic reference material, designated as USGS47, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and stable oxygen isotopic analysis of water with a mass spectrometer or a laser absorption spectrometer. "
This document provides graphical arrays and tables of key information on the derivation of human inhalation health effect reference values for specific chemicals, allowing comparisons across durations, populations, and intended use. A number of program offices within the Agency, ...
Method and apparatus for monitoring oxygen partial pressure in air masks
NASA Technical Reports Server (NTRS)
Kelly, Mark E. (Inventor); Pettit, Donald R. (Inventor)
2006-01-01
Method and apparatus are disclosed for monitoring an oxygen partial pressure in an air mask and providing a tactile warning to the user. The oxygen partial pressure in the air mask is detected using an electrochemical sensor, the output signal from which is provided to a comparator. The comparator compares the output signal with a preset reference value or range of values representing acceptable oxygen partial pressures. If the output signal is different than the reference value or outside the range of values, the air mask is vibrated by a vibrating motor to alert the user to a potentially hypoxic condition.
The Value Estimation of an HFGW Frequency Time Standard for Telecommunications Network Optimization
NASA Astrophysics Data System (ADS)
Harper, Colby; Stephenson, Gary
2007-01-01
The emerging technology of gravitational wave control is used to augment a communication system using a development roadmap suggested in Stephenson (2003) for applications emphasized in Baker (2005). In the present paper consideration is given to the value of a High Frequency Gravitational Wave (HFGW) channel purely as providing a method of frequency and time reference distribution for use within conventional Radio Frequency (RF) telecommunications networks. Specifically, the native value of conventional telecommunications networks may be optimized by using an unperturbed frequency time standard (FTS) to (1) improve terminal navigation and Doppler estimation performance via improved time difference of arrival (TDOA) from a universal time reference, and (2) improve acquisition speed, coding efficiency, and dynamic bandwidth efficiency through the use of a universal frequency reference. A model utilizing a discounted cash flow technique provides an estimation of the additional value using HFGW FTS technology could bring to a mixed technology HFGW/RF network. By applying a simple net present value analysis with supporting reference valuations to such a network, it is demonstrated that an HFGW FTS could create a sizable improvement within an otherwise conventional RF telecommunications network. Our conservative model establishes a low-side value estimate of approximately 50B USD Net Present Value for an HFGW FTS service, with reasonable potential high-side values to significant multiples of this low-side value floor.
Reference values of elements in human hair: a systematic review.
Mikulewicz, Marcin; Chojnacka, Katarzyna; Gedrange, Thomas; Górecki, Henryk
2013-11-01
The lack of systematic review on reference values of elements in human hair with the consideration of methodological approach. The absence of worldwide accepted and implemented universal reference ranges causes that hair mineral analysis has not become yet a reliable and useful method of assessment of nutritional status and exposure of individuals. Systematic review of reference values of elements in human hair. PubMed, ISI Web of Knowledge, Scopus. Humans, hair mineral analysis, elements or minerals, reference values, original studies. The number of studies screened and assessed for eligibility was 52. Eventually, included in the review were 5 papers. The studies report reference ranges for the content of elements in hair: macroelements, microelements, toxic elements and other elements. Reference ranges were elaborated for different populations in the years 2000-2012. The analytical methodology differed, in particular sample preparation, digestion and analysis (ICP-AES, ICP-MS). Consequently, the levels of hair minerals reported as reference values varied. It is necessary to elaborate the standard procedures and furtherly validate hair mineral analysis and deliver detailed methodology. Only then it would be possible to provide meaningful reference ranges and take advantage of the potential that lies in Hair Mineral Analysis as a medical diagnostic technique. Copyright © 2013 Elsevier B.V. All rights reserved.
Hermoso, Maria; Tabacchi, Garden; Iglesia-Altaba, Iris; Bel-Serrat, Silvia; Moreno-Aznar, Luis A; García-Santos, Yurena; García-Luzardo, Ma del Rosario; Santana-Salguero, Beatriz; Peña-Quintana, Luis; Serra-Majem, Lluis; Moran, Victoria Hall; Dykes, Fiona; Decsi, Tamás; Benetou, Vassiliki; Plada, Maria; Trichopoulou, Antonia; Raats, Monique M; Doets, Esmée L; Berti, Cristiana; Cetin, Irene; Koletzko, Berthold
2010-10-01
This paper presents a review of the current knowledge regarding the macro- and micronutrient requirements of infants and discusses issues related to these requirements during the first year of life. The paper also reviews the current reference values used in European countries and the methodological approaches used to derive them by a sample of seven European and international authoritative committees from which background scientific reports are available. Throughout the paper, the main issues contributing to disparities in micronutrient reference values for infants are highlighted. The identification of these issues in relation to the specific physiological aspects of infants is important for informing future initiatives aimed at providing standardized approaches to overcome variability of micronutrient reference values across Europe for this age group. © 2010 Blackwell Publishing Ltd.
Mexican-origin youths' trajectories of depressive symptoms: the role of familism values.
Zeiders, Katharine H; Updegraff, Kimberly A; Umaña-Taylor, Adriana J; Wheeler, Lorey A; Perez-Brena, Norma J; Rodríguez, Sue A
2013-11-01
To describe Mexican-origin youths' trajectories of depressive symptoms from early to late adolescence and examine the role of three aspects of familism values: supportive, obligation, and referent. Mexican-origin adolescents (N = 492) participated in home interviews and provided self-reports of depressive symptoms and cultural values at four assessments across an 8-year span. Using a cohort sequential design and accounting for the nesting within the 246 families (two youths per family), we examined depressive symptoms from ages 12 to 22 years and the within-person, between-sibling, and between-family effects of familism values. Mexican-origin males' depressive symptoms decreased across adolescence, whereas females' symptoms exhibited a cubic pattern of change. Results revealed that increases in supportive and referent familism values within individuals and across families were related to lower levels of depressive symptoms. Findings were most pronounced for referent familism values, as a between-sibling effect also emerged. Obligation familism values were not associated with depressive symptoms. Our findings provide important descriptive information about Mexican-origin youths' depressive symptoms and highlight the promotive role of familism values. Copyright © 2013 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.
Eikendal, Anouk L M; Bots, Michiel L; Haaring, Cees; Saam, Tobias; van der Geest, Rob J; Westenberg, Jos J M; den Ruijter, Hester M; Hoefer, Imo E; Leiner, Tim
2016-01-01
Reference values for morphological and functional parameters of the cardiovascular system in early life are relevant since they may help to identify young adults who fall outside the physiological range of arterial and cardiac ageing. This study provides age and sex specific reference values for aortic wall characteristics, cardiac function parameters and aortic pulse wave velocity (PWV) in a population-based sample of healthy, young adults using magnetic resonance (MR) imaging. In 131 randomly selected healthy, young adults aged between 25 and 35 years (mean age 31.8 years, 63 men) of the general-population based Atherosclerosis-Monitoring-and-Biomarker-measurements-In-The-YOuNg (AMBITYON) study, descending thoracic aortic dimensions and wall thickness, thoracic aortic PWV and cardiac function parameters were measured using a 3.0T MR-system. Age and sex specific reference values were generated using dedicated software. Differences in reference values between two age groups (25-30 and 30-35 years) and both sexes were tested. Aortic diameters and areas were higher in the older age group (all p<0.007). Moreover, aortic dimensions, left ventricular mass, left and right ventricular volumes and cardiac output were lower in women than in men (all p<0.001). For mean and maximum aortic wall thickness, left and right ejection fraction and aortic PWV we did not observe a significant age or sex effect. This study provides age and sex specific reference values for cardiovascular MR parameters in healthy, young Caucasian adults. These may aid in MR guided pre-clinical identification of young adults who fall outside the physiological range of arterial and cardiac ageing.
Risk Aversion and the Value of Information.
ERIC Educational Resources Information Center
Eeckhoudt, Louis; Godfroid, Phillippe
2000-01-01
Explains why risk aversion does not always induce a greater information value, but instead may induce a lower information value when increased. Presents a basic model defining the concept of perfect information value and providing a numerical illustration. Includes references. (CMK)
Reference values of inspiratory spirometry for Finnish adults.
Kainu, Annette; Timonen, Kirsi L; Vanninen, Esko; Sovijärvi, Anssi R
2018-03-07
Inspiratory spirometry is used in evaluation of upper airway disorders e.g. fixed or variable obstruction. There are, however, very few published data on normal values for inspiratory spirometry. The main aim of this study was to produce reference values for inspiratory spirometry for healthy Finnish adults. Inspiratory spirometry was preplanned to a sample of the Finnish spirometry reference values sample. Data was successfully retrieved from 368 healthy nonsmoking adults (132 males) between 19 and 83 years of age. Reference equations were produced for forced inspiratory vital capacity (FIVC), forced inspiratory volume in one second (FIV1), FIV1/FIVC, peak inspiratory flow (PIF) and the ratios of FIV1/forced expiratory volume in one second and PIF/peak expiratory flow. The present values were compared to PIF values from previously used Finnish study of Viljanen et al. (1982) reference values and Norwegian values for FIV1, FIVC and FIV1/FIVC presented by Gulsvik et al. (2001). The predicted values from the Gulsvik et al. (2001), provided a good fit for FIVC, but smaller values for FIV1 with mean 108.3 and 109.1% of predicted values for males and females, respectively. PIF values were 87.4 and 91.2% of Viljanen et al. (1982) predicted values in males and females, respectively. Differences in measurement methods and selection of results may contribute to the observed differences. Inspiratory spirometry is technically more demanding and needs repeatability criteria to improve validity. New reference values are suggested to clinical use in Finland when assessing inspiratory spirometry. Utility of inspiratory to expiratory values indices in assessment of airway collapse need further study.
FreeSolv: A database of experimental and calculated hydration free energies, with input files
Mobley, David L.; Guthrie, J. Peter
2014-01-01
This work provides a curated database of experimental and calculated hydration free energies for small neutral molecules in water, along with molecular structures, input files, references, and annotations. We call this the Free Solvation Database, or FreeSolv. Experimental values were taken from prior literature and will continue to be curated, with updated experimental references and data added as they become available. Calculated values are based on alchemical free energy calculations using molecular dynamics simulations. These used the GAFF small molecule force field in TIP3P water with AM1-BCC charges. Values were calculated with the GROMACS simulation package, with full details given in references cited within the database itself. This database builds in part on a previous, 504-molecule database containing similar information. However, additional curation of both experimental data and calculated values has been done here, and the total number of molecules is now up to 643. Additional information is now included in the database, such as SMILES strings, PubChem compound IDs, accurate reference DOIs, and others. One version of the database is provided in the Supporting Information of this article, but as ongoing updates are envisioned, the database is now versioned and hosted online. In addition to providing the database, this work describes its construction process. The database is available free-of-charge via http://www.escholarship.org/uc/item/6sd403pz. PMID:24928188
NASA Astrophysics Data System (ADS)
Dimbylow, Peter
2005-09-01
Finite-difference time-domain (FDTD) calculations have been performed of the whole-body averaged specific energy absorption rate (SAR) in a female voxel model, NAOMI, under isolated and grounded conditions from 10 MHz to 3 GHz. The 2 mm resolution voxel model, NAOMI, was scaled to a height of 1.63 m and a mass of 60 kg, the dimensions of the ICRP reference adult female. Comparison was made with SAR values from a reference male voxel model, NORMAN. A broad SAR resonance in the NAOMI values was found around 900 MHz and a resulting enhancement, up to 25%, over the values for the male voxel model, NORMAN. This latter result confirmed previously reported higher values in a female model. The effect of differences in anatomy was investigated by comparing values for 10-, 5- and 1-year-old phantoms rescaled to the ICRP reference values of height and mass which are the same for both sexes. The broad resonance in the NAOMI child values around 1 GHz is still a strong feature. A comparison has been made with ICNIRP guidelines. The ICNIRP occupational reference level provides a conservative estimate of the whole-body averaged SAR restriction. The linear scaling of the adult phantom using different factors in longitudinal and transverse directions, in order to match the ICRP stature and weight, does not exactly reproduce the anatomy of children. However, for public exposure the calculations with scaled child models indicate that the ICNIRP reference level may not provide a conservative estimate of the whole-body averaged SAR restriction, above 1.2 GHz for scaled 5- and 1-year-old female models, although any underestimate is by less than 20%.
Dimbylow, Peter
2005-09-07
Finite-difference time-domain (FDTD) calculations have been performed of the whole-body averaged specific energy absorption rate (SAR) in a female voxel model, NAOMI, under isolated and grounded conditions from 10 MHz to 3 GHz. The 2 mm resolution voxel model, NAOMI, was scaled to a height of 1.63 m and a mass of 60 kg, the dimensions of the ICRP reference adult female. Comparison was made with SAR values from a reference male voxel model, NORMAN. A broad SAR resonance in the NAOMI values was found around 900 MHz and a resulting enhancement, up to 25%, over the values for the male voxel model, NORMAN. This latter result confirmed previously reported higher values in a female model. The effect of differences in anatomy was investigated by comparing values for 10-, 5- and 1-year-old phantoms rescaled to the ICRP reference values of height and mass which are the same for both sexes. The broad resonance in the NAOMI child values around 1 GHz is still a strong feature. A comparison has been made with ICNIRP guidelines. The ICNIRP occupational reference level provides a conservative estimate of the whole-body averaged SAR restriction. The linear scaling of the adult phantom using different factors in longitudinal and transverse directions, in order to match the ICRP stature and weight, does not exactly reproduce the anatomy of children. However, for public exposure the calculations with scaled child models indicate that the ICNIRP reference level may not provide a conservative estimate of the whole-body averaged SAR restriction, above 1.2 GHz for scaled 5- and 1-year-old female models, although any underestimate is by less than 20%.
Optimal weighted combinatorial forecasting model of QT dispersion of ECGs in Chinese adults.
Wen, Zhang; Miao, Ge; Xinlei, Liu; Minyi, Cen
2016-07-01
This study aims to provide a scientific basis for unifying the reference value standard of QT dispersion of ECGs in Chinese adults. Three predictive models including regression model, principal component model, and artificial neural network model are combined to establish the optimal weighted combination model. The optimal weighted combination model and single model are verified and compared. Optimal weighted combinatorial model can reduce predicting risk of single model and improve the predicting precision. The reference value of geographical distribution of Chinese adults' QT dispersion was precisely made by using kriging methods. When geographical factors of a particular area are obtained, the reference value of QT dispersion of Chinese adults in this area can be estimated by using optimal weighted combinatorial model and reference value of the QT dispersion of Chinese adults anywhere in China can be obtained by using geographical distribution figure as well.
Li, Meng-Jiao; Ge, Miao; Wang, Cong-Xia; Cen, Min-Yi; Jiang, Ji-Lin; He, Jin-Wei; Lin, Qian-Yi; Liu, Xin
2016-08-20
To analyze the relationship between the reference values of fibrinogen (FIB) in healthy Chinese adults and geographical factors to provide scientific evidences for establishing the uniform standard. The reference values of FIB of 10701 Chinese healthy adults from 103 cities were collected to investigate their relationship with 18 geographical factors including spatial index, terrain index, climate index, and soil index. Geographical factors that significantly correlated with the reference values were selected for constructing the BP neural network model. The spatial distribution map of the reference value of FIB of healthy Chinese adults was fitted by disjunctive kriging interpolation. We used the 5-layer neural network and selected 2000 times of training covering 11 hidden layers to build the simulation rule for simulating the relationship between FIB and geographical environmental factors using the MATLAB software. s The reference value of FIB in healthy Chinese adults was significantly correlated with the latitude, sunshine duration, annual average temperature, annual average relative humidity, annual precipitation, annual range of air temperature, average annual soil gravel content, and soil cation exchange capacity (silt). The artificial neural networks were created to analyze the simulation of the selected indicators of geographical factors. The spatial distribution map of the reference values of FIB in healthy Chinese adults showed a distribution pattern that FIB levels were higher in the South and lower in the North, and higher in the East and lower in the West. When the geographical factors of a certain area are known, the reference values of FIB in healthy Chinese adults can be obtained by establishing the neural network mode or plotting the spatial distribution map.
[The Study of Health in Pomerania (SHIP) reference values for cardiopulmonary exercise testing].
Gläser, S; Ittermann, T; Schäper, C; Obst, A; Dörr, M; Spielhagen, T; Felix, S B; Völzke, H; Bollmann, T; Opitz, C F; Warnke, C; Koch, B; Ewert, R
2013-01-01
The interpretation of gas exchange measured by cardiopulmonary exercise testing (CPET) depends on reliable reference values. Within the population based Study of Health in Pomerania (SHIP) CPET was assessed in 1706 volunteers. The assessment based on symptom limited exercise tests on a bicycle in a sitting position according to a modified Jones protocol. CPET was embedded in an extensive examination program. After the exclusion of active smokers and volunteers with evidence of cardiopulmonary and musculoskeletal disorders the reference population comprised 616 healthy subjects (333 women) aged 25 to 85 years. Reference equations including upper and/or lower limits based on quantile regression were assessed. All values were corrected for the most important influencing factors.This study provides reference equations for gas exchange and exercise capacity assessed within a population in Germany. © Georg Thieme Verlag KG Stuttgart · New York.
Chiu, C H; Turle, R; Poole, G; Thibert, B; Brubaker, W W; Schantz, M M; Wise, S A
2001-02-01
Due to the limited number of environmental matrix certified reference materials (CRMs) with assigned values for natural levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), an interlaboratory study was undertaken by the National Institute of Standards and Technology (NIST) and Environment Canada to establish reference concentration values for selected PCDD/Fs in two well-characterized NIST Standard Reference Materials (SRMs): SRM 1649a (Urban Dust) and SRM 1944 (New York/New Jersey Waterway Sediment). Results from 14 laboratories were used to provide reference values for the seventeen 2, 3, 7, 8-substituted PCDD/F congeners, the totals for individual tetra- through hepta-substituted PCDD/F homologues, and the total amount of tetra- through hepta-substituted PCDD/Fs. The mass fractions for the individual 2, 3, 7, 8-substituted congeners range from approximately 0.01 microg/kg to 7 microg/kg dry mass.
Pressure and cold pain threshold reference values in a large, young adult, pain-free population.
Waller, Robert; Smith, Anne Julia; O'Sullivan, Peter Bruce; Slater, Helen; Sterling, Michele; McVeigh, Joanne Alexandra; Straker, Leon Melville
2016-10-01
Currently there is a lack of large population studies that have investigated pain sensitivity distributions in healthy pain free people. The aims of this study were: (1) to provide sex-specific reference values of pressure and cold pain thresholds in young pain-free adults; (2) to examine the association of potential correlates of pain sensitivity with pain threshold values. This study investigated sex specific pressure and cold pain threshold estimates for young pain free adults aged 21-24 years. A cross-sectional design was utilised using participants (n=617) from the Western Australian Pregnancy Cohort (Raine) Study at the 22-year follow-up. The association of site, sex, height, weight, smoking, health related quality of life, psychological measures and activity with pain threshold values was examined. Pressure pain threshold (lumbar spine, tibialis anterior, neck and dorsal wrist) and cold pain threshold (dorsal wrist) were assessed using standardised quantitative sensory testing protocols. Reference values for pressure pain threshold (four body sites) stratified by sex and site, and cold pain threshold (dorsal wrist) stratified by sex are provided. Statistically significant, independent correlates of increased pressure pain sensitivity measures were site (neck, dorsal wrist), sex (female), higher waist-hip ratio and poorer mental health. Statistically significant, independent correlates of increased cold pain sensitivity measures were, sex (female), poorer mental health and smoking. These data provide the most comprehensive and robust sex specific reference values for pressure pain threshold specific to four body sites and cold pain threshold at the dorsal wrist for young adults aged 21-24 years. Establishing normative values in this young age group is important given that the transition from adolescence to adulthood is a critical temporal period during which trajectories for persistent pain can be established. These data will provide an important research resource to enable more accurate profiling and interpretation of pain sensitivity in clinical pain disorders in young adults. The robust and comprehensive data can assist interpretation of future clinical pain studies and provide further insight into the complex associations of pain sensitivity that can be used in future research. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Verschuren, Olaf; Bloemen, Manon; Kruitwagen, Cas; Takken, Tim
2010-01-01
Aim: The aim of this study was to provide reference values of anaerobic performance and agility in a group of children and adolescents with spastic cerebral palsy (CP). Method: A total of 300 children (184 males, 116 females) with spastic CP were recruited from 26 rehabilitation centres in six different countries. Of these, 215 were classified at…
Qi, Haiping; Coplen, Tyler B.; Tarbox, Lauren V.; Lorenz, Jennifer M.; Scholl, Martha A.
2014-01-01
A new secondary isotopic reference material has been prepared from Puerto Rico precipitation, which was filtered, homogenised, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and calibrated by dual-inlet isotope-ratio mass spectrometry. This isotopic reference material, designated as USGS48, is intended to be one of two isotopic reference waters for daily normalisation of stable hydrogen (δ2H) and stable oxygen (δ18O) isotopic analysis of water with a mass spectrometer or a laser absorption spectrometer. The δ2H and δ18O values of this reference water are−2.0±0.4 and−2.224±0.012 ‰, respectively, relative to Vienna Standard Mean Ocean Water on scales normalised such that the δ2H and δ18O values of Standard Light Antarctic Precipitation reference water are−428 and−55.5 ‰, respectively. Each uncertainty is an estimated expanded uncertainty (U=2uc) about the reference value that provides an interval that has about a 95 % probability of encompassing the true value. This isotopic reference water is available by the case of 144 glass ampoules containing 5 mL of water in each ampoule.
Reference values for anxiety questionnaires: the Leiden Routine Outcome Monitoring Study.
Schulte-van Maaren, Yvonne W M; Giltay, Erik J; van Hemert, Albert M; Zitman, Frans G; de Waal, Margot W M; Carlier, Ingrid V E
2013-09-25
The monitoring of patients with an anxiety disorder can benefit from Routine Outcome Monitoring (ROM). As anxiety disorders differ in phenomenology, several anxiety questionnaires are included in ROM: Brief Scale for Anxiety (BSA), PADUA Inventory Revised (PI-R), Panic Appraisal Inventory (PAI), Penn State Worry Questionnaire (PSWQ), Worry Domains Questionnaire (WDQ), Social Interaction, Anxiety Scale (SIAS), Social Phobia Scale (SPS), and the Impact of Event Scale-Revised (IES-R). We aimed to generate reference values for both 'healthy' and 'clinically anxious' populations for these anxiety questionnaires. We included 1295 subjects from the general population (ROM reference-group) and 5066 psychiatric outpatients diagnosed with a specific anxiety disorder (ROM patient-group). The MINI was used as diagnostic device in both the ROM reference group and the ROM patient group. To define limits for one-sided reference intervals (95th percentile; P95) the outermost 5% of observations were used. Receiver Operating Characteristics (ROC) analyses were used to yield alternative cut-off values for the anxiety questionnaires. For the ROM reference-group the mean age was 40.3 years (SD=12.6), and for the ROM patient-group it was 36.5 years (SD=11.9). Females constituted 62.8% of the reference-group and 64.4% of the patient-group. P95 ROM reference group cut-off values for reference versus clinically anxious populations were 11 for the BSA, 43 for the PI-R, 37 for the PAI Anticipated Panic, 47 for the PAI Perceived Consequences, 65 for the PAI Perceived Self-efficacy, 66 for the PSWQ, 74 for the WDQ, 32 for the SIAS, 19 for the SPS, and 36 for IES-R. ROC analyses yielded slightly lower reference values. The discriminative power of all eight anxiety questionnaires was very high. Substantial non-response and limited generalizability. For eight anxiety questionnaires a comprehensive set of reference values was provided. Reference values were generally higher in women than in men, implying the use of gender-specific cut-off values. Each instrument can be offered to every patient with MAS disorders to make responsible decisions about continuing, changing or terminating therapy. © 2013 Elsevier B.V. All rights reserved.
Critical laboratory values in hemostasis: toward consensus.
Lippi, Giuseppe; Adcock, Dorothy; Simundic, Ana-Maria; Tripodi, Armando; Favaloro, Emmanuel J
2017-09-01
The term "critical values" can be defined to entail laboratory test results that significantly lie outside the normal (reference) range and necessitate immediate reporting to safeguard patient health, as well as those displaying a highly and clinically significant variation compared to previous data. The identification and effective communication of "highly pathological" values has engaged the minds of many clinicians, health care and laboratory professionals for decades, since these activities are vital to good laboratory practice. This is especially true in hemostasis, where a timely and efficient communication of critical values strongly impacts patient management. Due to the heterogeneity of available data, this paper is hence aimed to analyze the state of the art and provide an expert opinion about the parameters, measurement units and alert limits pertaining to critical values in hemostasis, thus providing a basic document for future consultation that assists laboratory professionals and clinicians alike. KEY MESSAGES Critical values are laboratory test results significantly lying outside the normal (reference) range and necessitating immediate reporting to safeguard patient health. A broad heterogeneity exists about critical values in hemostasis worldwide. We provide here an expert opinion about the parameters, measurement units and alert limits pertaining to critical values in hemostasis.
Beaufrère, Hugues; Acierno, Mark; Mitchell, Mark; Guzman, David Sanchez-Migallon; Bryant, Heather; Tully, Thomas N
2011-06-01
Birds are routinely presented to veterinarians for dehydration. Success with these cases ultimately depends on providing replacement fluids and re-establishing fluid homeostasis. Few studies have been done to determine reference ranges for plasma osmolality in birds. The goals of this study were to determine reference values for plasma osmolality in 3 species of parrots and to provide recommendations on fluid selection for replacement therapy in these species. Blood samples were collected from 21 adult Hispaniolan Amazon parrots (Amazona ventralis), 21 Congo African grey parrots (Psittacus erithacus erithacus), and 9 red-fronted macaws (Ara rubrogenys), and were placed into lithium heparin containers. Plasma osmolality was measured in duplicate with a freezing point depression osmometer. Summary statistics were computed from the average values. Reference ranges, calculated by using the robust method, were 288-324, 308-345, and 223-369 mOsm/kg in African grey parrots, Hispaniolan Amazon parrots, and red-fronted macaws, respectively. The mean +/- SD values were 306 +/- 7, 327 +/- 7, and 304 +/- 18 mOsm/kg in African grey parrots, Hispaniolan Amazon parrots, and red-fronted macaws, respectively. Comparisons with osmolality values in mammals and values previously reported for psittacine bird species suggest that plasma osmolality is slightly higher in parrots than in mammals, species-specific differences exist, and differences between reported values occur. Overall, fluids with an osmolarity close to 300-320 mOsm/L, such as Normosol-R, Plasmalyte-R, Plasmalyte-A, and NaCl 0.9%, can be recommended in parrots for fluid replacement therapy when isotonic fluids are required.
Tveter, Anne Therese; Dagfinrud, Hanne; Moseng, Tuva; Holm, Inger
2014-07-01
To provide reference values and reference equations for frequently used clinical field tests of health-related physical fitness for use in clinical practice. Cross-sectional design. General community. Convenience sample of volunteers (N=370) between 18 and 90 years of age were recruited from a wide range of settings (ie, work sites, schools, community centers for older adults) and different geographic locations (ie, urban, suburban, rural) in southeastern Norway. Not applicable. The participants conducted 5 clinical field tests (6-minute walk test, stair test, 30-second sit-to-stand test, handgrip test, fingertip-to-floor test). The results of the field tests showed that performance remained unchanged until approximately 50 years of age; after that, performance deteriorated with increasing age. Grip strength (79%), meters walked in 6 minutes (60%), and seconds used on the stair test (59%) could be well predicted by age, sex, height, and weight in participants ≥50 years of age, whereas the performance on all tests was less well predicted in participants <50 years of age. The reference values and reference equations provided in this study may increase the applicability and interpretability of the 6-minute walk test, stair test, 30-second sit-to-stand test, handgrip test, and fingertip-to-floor test in clinical practice. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Han, Xiao; Ge, Miao; Dong, Jie; Xue, Ranying; Wang, Zixuan; He, Jinwei
2014-09-01
The aim of this paper is to analyze the geographical distribution of reference value of aging people's left ventricular end systolic diameter (LVDs), and to provide a scientific basis for clinical examination. The study is focus on the relationship between reference value of left ventricular end systolic diameter of aging people and 14 geographical factors, selecting 2495 samples of left ventricular end systolic diameter (LVDs) of aging people in 71 units of China, in which including 1620 men and 875 women. By using the Moran's I index to make sure the relationship between the reference values and spatial geographical factors, extracting 5 geographical factors which have significant correlation with left ventricular end systolic diameter for building the support vector regression, detecting by the method of paired sample t test to make sure the consistency between predicted and measured values, finally, makes the distribution map through the disjunctive kriging interpolation method and fits the three-dimensional trend of normal reference value. It is found that the correlation between the extracted geographical factors and the reference value of left ventricular end systolic diameter is quite significant, the 5 indexes respectively are latitude, annual mean air temperature, annual mean relative humidity, annual precipitation amount, annual range of air temperature, the predicted values and the observed ones are in good conformity, there is no significant difference at 95% degree of confidence. The overall trend of predicted values increases from west to east, increases first and then decreases from north to south. If geographical values are obtained in one region, the reference value of left ventricular end systolic diameter of aging people in this region can be obtained by using the support vector regression model. It could be more scientific to formulate the different distributions on the basis of synthesizing the physiological and the geographical factors. -Use Moran's index to analyze the spatial correlation. -Choose support vector machine to build model that overcome complexity of variables. -Test normal distribution of predicted data to guarantee the interpolation results. -Through trend analysis to explain the changes of reference value clearly. Copyright © 2014 Elsevier Inc. All rights reserved.
Lorenz, Jennifer M.; Tarbox, Lauren V.; Buck, Bryan; Qi, Haiping; Coplen, Tyler B.
2014-01-01
RATIONALE As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from drinking water collected from the Biscayne aquifer in Ft. Lauderdale, Florida. METHODS This isotopic reference water was filtered, homogenized, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and measured by dual-inlet isotope-ratio mass spectrometry. This reference material is available by the case of 144 glass ampoules containing either 4 mL or 5 mL of water in each ampoule. RESULTS The δ2H and δ18O values of this reference material are –10.3 ± 0.4 ‰ and –2.238 ± 0.011 ‰, respectively, relative to VSMOW, on scales normalized such that the δ2H and δ18O values of SLAP reference water are, respectively, –428 and –55.5 ‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95 % probability of encompassing the true value. CONCLUSIONS This isotopic reference material, designated as USGS45, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer.
Coplen, Tyler B.; Qi, Haiping; Tarbox, Lauren V.; Lorenz, Jennifer M.; Buck, Bryan
2015-01-01
Ice core from Greenland was melted, filtered, homogenised, loaded into glass ampoules, sealed, autoclaved to eliminate biological activity, and calibrated by dual-inlet isotope-ratio mass spectrometry. This isotopic reference material (RM), USGS46, is intended as one of two secondary isotopic reference waters for daily normalisation of stable hydrogen (δ2H) and stable oxygen (δ18O) isotopic analysis of water with a mass spectrometer or a laser absorption spectrometer. The measured δ2H and δ18O values of this reference water were −235.8 ± 0.7‰ and −29.80 ± 0.03‰, respectively, relative to VSMOW on scales normalised such that the δ2H and δ18O values of SLAP reference water are, respectively, −428 and −55.5‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95-percent probability of encompassing the true value. This reference water is available in cases containing 144 glass ampoules that are filled with either 4 ml or 5 ml of water per ampoule.
Life Support Baseline Values and Assumptions Document
NASA Technical Reports Server (NTRS)
Anderson, Molly S.; Ewert, Michael K.; Keener, John F.
2018-01-01
The Baseline Values and Assumptions Document (BVAD) provides analysts, modelers, and other life support researchers with a common set of values and assumptions which can be used as a baseline in their studies. This baseline, in turn, provides a common point of origin from which many studies in the community may depart, making research results easier to compare and providing researchers with reasonable values to assume for areas outside their experience. This document identifies many specific physical quantities that define life support systems, serving as a general reference for spacecraft life support system technology developers.
NASA Astrophysics Data System (ADS)
Bernardi, F.; Lomax, A.; Michelini, A.; Lauciani, V.; Piatanesi, A.; Lorito, S.
2015-09-01
In this paper we present and discuss the performance of the procedure for earthquake location and characterization implemented in the Italian Candidate Tsunami Service Provider at the Istituto Nazionale di Geofisica e Vulcanologia (INGV) in Rome. Following the ICG/NEAMTWS guidelines, the first tsunami warning messages are based only on seismic information, i.e., epicenter location, hypocenter depth, and magnitude, which are automatically computed by the software Early-est. Early-est is a package for rapid location and seismic/tsunamigenic characterization of earthquakes. The Early-est software package operates using offline-event or continuous-real-time seismic waveform data to perform trace processing and picking, and, at a regular report interval, phase association, event detection, hypocenter location, and event characterization. Early-est also provides mb, Mwp, and Mwpd magnitude estimations. mb magnitudes are preferred for events with Mwp ≲ 5.8, while Mwpd estimations are valid for events with Mwp ≳ 7.2. In this paper we present the earthquake parameters computed by Early-est between the beginning of March 2012 and the end of December 2014 on a global scale for events with magnitude M ≥ 5.5, and we also present the detection timeline. We compare the earthquake parameters automatically computed by Early-est with the same parameters listed in reference catalogs. Such reference catalogs are manually revised/verified by scientists. The goal of this work is to test the accuracy and reliability of the fully automatic locations provided by Early-est. In our analysis, the epicenter location, hypocenter depth and magnitude parameters do not differ significantly from the values in the reference catalogs. Both mb and Mwp magnitudes show differences to the reference catalogs. We thus derived correction functions in order to minimize the differences and correct biases between our values and the ones from the reference catalogs. Correction of the Mwp distance dependency is particularly relevant, since this magnitude refers to the larger and probably tsunamigenic earthquakes. Mwp values at stations with epicentral distance Δ ≲ 30° are significantly overestimated with respect to the CMT-global solutions, whereas Mwp values at stations with epicentral distance Δ ≳ 90° are slightly underestimated. After applying such distance correction the Mwp provided by Early-est differs from CMT-global catalog values of about δ Mwp ≈ 0.0 ∓ 0.2. Early-est continuously acquires time-series data and updates the earthquake source parameters. Our analysis shows that the epicenter coordinates and the magnitude values converge within less than 10 min (5 min in the Mediterranean region) toward the stable values. Our analysis shows that we can compute Mwp magnitudes that do not display short epicentral distance dependency overestimation, and we can provide robust and reliable earthquake source parameters to compile tsunami warning messages within less than 15 min after the event origin time.
Randall S. Rosenberger; John B. Loomis
2001-01-01
We present an annotated bibliography that provides information on and reference to the literature on outdoor recreation use valuation studies. This information is presented by study source, benefit measures, recreation activity, valuation methodology, and USDA Forest Service region. Tables are provided that reference the bibliography for each activity, enabling easy...
Kaafarani, Mirna; Schroer, Christian; Takken, Tim
2017-12-01
Hemodynamic responses to exercise are used as markers of diagnosis for cardiac diseases, systolic blood pressure (SBP) especially. However, the reference values for SBP in children at peak exertion level are outdated. This study aimed to establish current reference values for SBP, rate pressure product (RPP), and circulatory power (CircP). Data from children who previously underwent cardiopulmonary exercise testing were categorized as healthy (N = 184; age 12.6 ± 2.9 years), and CoA patients (N = 25; age 13.0 ± 3.2 years). With the Lambda-Mu-Sigma (LMS) method, percentile curves were made for SBP, CircP, and RPP in function of peak work rate (Wpeak). Data of CoA patients were used to validate the reference values. Wpeak was the best predictor of peak SBP during exercise. The prediction equations for SBP, CircP and RPP were: (0.2853 x Wpeak) + 111.46; (10.56 x Wpeak) + 2550.2 and (61.879 x Wpeak) + 19.887, respectively. CoA patients showed significantly increased values for peak SBP (Z-score 1.063 ± 1.347). This study provides reference values for SBP, RPP, and CircP at peak exercise. These values can be used for objective evaluation of participants 6-18 years of age in a Dutch population.
Adeli, Khosrow; Higgins, Victoria; Nieuwesteeg, Michelle; Raizman, Joshua E; Chen, Yunqi; Wong, Suzy L; Blais, David
2015-08-01
Defining laboratory biomarker reference values in a healthy population and understanding the fluctuations in biomarker concentrations throughout life and between sexes are critical to clinical interpretation of laboratory test results in different disease states. The Canadian Health Measures Survey (CHMS) has collected blood samples and health information from the Canadian household population. In collaboration with the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER), the data have been analyzed to determine reference value distributions and reference intervals for several endocrine and special chemistry biomarkers in pediatric, adult, and geriatric age groups. CHMS collected data and blood samples from thousands of community participants aged 3 to 79 years. We used serum samples to measure 13 immunoassay-based special chemistry and endocrine markers. We assessed reference value distributions and, after excluding outliers, calculated age- and sex-specific reference intervals, along with corresponding 90% CIs, according to CLSI C28-A3 guidelines. We observed fluctuations in biomarker reference values across the pediatric, adult, and geriatric age range, with stratification required on the basis of age for all analytes. Additional sex partitions were required for apolipoprotein AI, homocysteine, ferritin, and high sensitivity C-reactive protein. The unique collaboration between CALIPER and CHMS has enabled, for the first time, a detailed examination of the changes in various immunochemical markers that occur in healthy individuals of different ages. The robust age- and sex-specific reference intervals established in this study provide insight into the complex biological changes that take place throughout development and aging and will contribute to improved clinical test interpretation. © 2015 American Association for Clinical Chemistry.
Brian Roy Lockhart
2004-01-01
The author discusses the values of American hornbeam (Carpinus caroliniana), also known as ironwood, blue-beech, or muscle-wood. He details the benefits provided by American hornbeam, though frequently referred to as a weed. Lockhart provides the context in which less desirable species can benefit the forest and the species for which the land is being managed.
Effect of defuzzification method of fuzzy modeling
NASA Astrophysics Data System (ADS)
Lapohos, Tibor; Buchal, Ralph O.
1994-10-01
Imprecision can arise in fuzzy relational modeling as a result of fuzzification, inference and defuzzification. These three sources of imprecision are difficult to separate. We have determined through numerical studies that an important source of imprecision is the defuzzification stage. This imprecision adversely affects the quality of the model output. The most widely used defuzzification algorithm is known by the name of `center of area' (COA) or `center of gravity' (COG). In this paper, we show that this algorithm not only maps the near limit values of the variables improperly but also introduces errors for middle domain values of the same variables. Furthermore, the behavior of this algorithm is a function of the shape of the reference sets. We compare the COA method to the weighted average of cluster centers (WACC) procedure in which the transformation is carried out based on the values of the cluster centers belonging to each of the reference membership functions instead of using the functions themselves. We show that this procedure is more effective and computationally much faster than the COA. The method is tested for a family of reference sets satisfying certain constraints, that is, for any support value the sum of reference membership function values equals one and the peak values of the two marginal membership functions project to the boundaries of the universe of discourse. For all the member sets of this family of reference sets the defuzzification errors do not get bigger as the linguistic variables tend to their extreme values. In addition, the more reference sets that are defined for a certain linguistic variable, the less the average defuzzification error becomes. In case of triangle shaped reference sets there is no defuzzification error at all. Finally, an alternative solution is provided that improves the performance of the COA method.
Kalkwarf, Heidi J.; Gilsanz, Vicente; Lappe, Joan M.; Oberfield, Sharon; Shepherd, John A.; Frederick, Margaret M.; Huang, Xiangke; Lu, Ming; Mahboubi, Soroosh; Hangartner, Thomas; Winer, Karen K.
2011-01-01
Context: Deficits in bone acquisition during growth may increase fracture risk. Assessment of bone health during childhood requires appropriate reference values relative to age, sex, and population ancestry to identify bone deficits. Objective: The objective of this study was to provide revised and extended reference curves for bone mineral content (BMC) and areal bone mineral density (aBMD) in children. Design: The Bone Mineral Density in Childhood Study was a multicenter longitudinal study with annual assessments for up to 7 yr. Setting: The study was conducted at five clinical centers in the United States. Participants: Two thousand fourteen healthy children (992 males, 22% African-Americans) aged 5–23 yr participated in the study. Intervention: There were no interventions. Main Outcome Measures: Reference percentiles for BMC and aBMD of the total body, lumbar spine, hip, and forearm were obtained using dual-energy x-ray absorptiometry for Black and non-Black children. Adjustment factors for height status were also calculated. Results: Extended reference curves for BMC and aBMD of the total body, total body less head, lumbar spine, total hip, femoral neck, and forearm for ages 5–20 yr were constructed relative to sex and age for Black and non-Black children. Curves are similar to those previously published for 7–17 year olds. BMC and aBMD values were greater for Black vs. non-Black children at all measurement sites. Conclusions: We provide here dual-energy x-ray absorptiometry reference data on a well-characterized cohort of 2012 children and adolescents. These reference curves provide the most robust reference values for the assessment and monitoring of bone health in children and adolescents in the literature to date. PMID:21917867
Age-related differences in limb fat-free mass and fat mass in healthy Chinese Adults.
Bai, Mei; Wang, Rui; Zhu, Linhao; Li, Guixin; Yuan, Dongya; Wang, Li; Jin, Tianbo
2018-05-22
Fat mass (FM) and fat-free mass (FFM) are important elements to evaluate nutritional status. The aims of this study were to establish reference values for FM and FFM of limbs, develop percentile distributions and assess age-related regional differences in body composition by multifrequency bioelectrical impedance analyzer (BIA) in healthy adults. A cross-sectional study was conducted on 3419 healthy subjects, 1595 men and 1824 women. Regional FM and FFM were measured by BIA. FM in men remained stable in both upper and lower limbs, with reference values (25-75th percentile) of 1-1.5 kg and 4.9-7.2 kg, respectively. Women's leg FM remained stable with aging (reference values 6.2-7.9 kg), increasing in their arms (0.9-1.5 kg for youngest, 1.3-2.3 kg oldest). The reference values of upper limbs FFM were 5.3-6.2 kg in men and 3.3-3.9 kg in women. Lower limbs FFM decreased with age in both gender: the reference values were 19.5-23.3 kg (men) and 13.8-15.4 kg (women) for 18-30 age group, and 17.3-20 kg and 11.2-13.1 kg, respectively, for 60+ age group. These data provided reference values of FM and FFM in both limbs, enabling the identification of age and gender-related changes in limb composition in healthy Chinese subjects.
Marrodán Serrano, María Dolores; González-Montero de Espinosa, Marisa; Herráez, Ángel; Alfaro, Emma Laura; Felipe Bejarano, Ignacio; Carmenate, María Margarita; Prado, Consuelo; Beatriz Lomaglio, Delia; López-Ejeda, Noemí; Martínez, Antonio; Mesa, María Soledad; Méndez Pérez, Betty; Meléndez, Juana María; Moreno Romero, Susana; Pacheco, Jose Luis; Vázquez, Vanessa; Dipierri, José E
2015-12-01
the assessment of the skinfold thickness is an objective measure of adiposity. Therefore, it is a useful tool for nutritional diagnosis and prevention of metabolic risk associated with excess fat in chilhood and adolescence. to provide percentiles of subscapular and triceps skinfolds for Hispanic American schoolchildren and compare them with those published by the Centers for Disease Control and Prevention (CDC) from United States, that it have been commonly used as a reference in most of these countries. subscapular and triceps skinfolds were measured in 9.973 schoolchildren 4-19 aged from Spain, Argentina, Cuba, Venezuela and Mexico with Holtain caliper with 0.2 mm accuracy. Percentiles were obtained with the LMS statistical method and were presented in tables divided in stages of 6 months and in curves graphics. The difference between Hispanic American and CDC mean values were provided for P3, P50 and P97 in mm and also were graphically represented. skinfolds measurements obviously increased with age in both sexes but, in boys, this increase is much more marked in highest percentiles between 8 and 13 years; this maximum is reached earlier than what occurs in CDC reference. In both sexes, all percentiles analized in Hispanic American schoolchildren were higher than the CDC reference except P97 up to 10 or 13 years that was notably smaller. the skinfolds percentiles of Hispanic American children and adolescents differ from CDC that are usually used as reference. The values of subscapular and triceps skinfolds provided in this study, could be applied to populations of a similar ethnic background, especially in comparative studies of body composition. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Git, K-A; Fioravante, L A B; Fernandes, J L
2015-09-01
To assess whether an online open-source tool would provide accurate calculations of T2(*) values for iron concentrations in the liver and heart compared with a standard reference software. An online open-source tool, written in pure HTML5/Javascript, was tested in 50 patients (age 26.0 ± 18.9 years, 46% males) who underwent T2(*) MRI of the liver and heart for iron overload assessment as part of their routine workup. Automated truncation correction was the default with optional manual adjustment provided if needed. The results were compared against a standard reference measurement using commercial software with manual truncation (CVI(42)(®) v. 5.1; Circle Cardiovascular Imaging; Calgary, AB). The mean liver T2(*) values calculated with the automated tool was 4.3 ms [95% confidence interval (CI) 3.1 to 5.5 ms] vs 4.26 ms using the reference software (95% CI 3.1 to 5.4 ms) without any significant differences (p = 0.71). In the liver, the mean difference was 0.036 ms (95% CI -0.1609 to 0.2329 ms) with a regression correlation coefficient of 0.97. For the heart, the automated T2(*) value was 26.0 ms (95% CI 22.9 to 29.0 ms) vs 25.3 ms (95% CI 22.3 to 28.3 ms), p = 0.28. The mean difference was 0.72 ms (95% CI 0.08191 to 1.3621 ms) with a correlation coefficient of 0.96. The automated online tool provides similar T2(*) values for the liver and myocardial iron concentrations as compared with a standard reference software. The online program provides an open-source tool for the calculation of T2(*) values, incorporating an automated correction algorithm in a simple and easy-to-use interface.
[Study on blood pressure standard in children using the automatic sphygmomanometer].
Niida, Mami; Hataya, Hiroshi; Honda, Masataka
2015-01-01
In Japan, two treatment guidelines exist for pediatric patients with hypertension. The Guidelines for Drug Therapy in Pediatric Patients with Cardiovascular Diseases (JCS2012), by the Japanese Circulation Society, cite the stethoscopy-based American guidelines. The Guidelines for the Management of Hypertension (JSH2009), by the Japanese Society of Hypertension, focus on Japanese data obtained from automated sphygmomanometry. The frequent use of automated sphygmomanometers in clinical practice implies that the JSH2009 guidelines might be better; however with strict low reference values for the diastolic phase, overtreatment may result. Only the Japanese Circulation Society's guidelines include a therapeutic strategy, and the Chronic Kidney Disease (CKD) Guide, CKD Guidelines, and school urinary screening tests all cite these guidelines on stethoscopy-based blood pressure determination. Stethoscopy should be conducted during a medical examination; however, due to limited time in clinical practice, most physicians use automated sphygmomanometers while nevertheless relying on the Japanese Circulation Society reference values--which are stethoscopy-based. To find a compromise, we compared reference values in Japan with those from South Korea (automated sphygmomanometer-based) and those from the United States (stethoscopy-based). Moreover, we examined the results of recent accuracy tests for automated sphygmomanometers. Although the JSH2009 reference values for the systolic phase were consistent with those in the United States (stethoscopy-based), the reference values for the diastolic phase were lower. We observed the same tendency when comparing JSH2009 reference values with those in South Korea (automated sphygmomanometer-based). Conversely, there were only small differences between automated sphygmomanometry and mercury measurement, and we found it was possible to substitute the values from automated sphygmomanometry for stethoscopy. A large-scale study that takes into account patient height, measurement method, and treatment criteria is required to establish appropriate reference values. Even if automated sphygmomanometry is used until appropriate values are established, we consider the criteria provided in the American guidelines as appropriate.
Hartlage, Gregory R; Kim, Jonathan H; Strickland, Patrick T; Cheng, Alan C; Ghasemzadeh, Nima; Pernetz, Maria A; Clements, Stephen D; Williams, B Robinson
2015-03-01
Speckle-tracking left ventricular global longitudinal strain (GLS) assessment may provide substantial prognostic information for hypertrophic cardiomyopathy (HCM) patients. Reference values for GLS have been recently published. We aimed to evaluate the prognostic value of standardized reference values for GLS in HCM patients. An analysis of HCM clinic patients who underwent GLS was performed. GLS was defined as normal (more negative or equal to -16%) and abnormal (less negative than -16%) based on recently published reference values. Patients were followed for a composite of events including heart failure hospitalization, sustained ventricular arrhythmia, and all-cause death. The power of GLS to predict outcomes was assessed relative to traditional clinical and echocardiographic variables present in HCM. 79 HCM patients were followed for a median of 22 months (interquartile range 9-30 months) after imaging. During follow-up, 15 patients (19%) met the primary outcome. Abnormal GLS was the only echocardiographic variable independently predictive of the primary outcome [multivariate Hazard ratio 5.05 (95% confidence interval 1.09-23.4, p = 0.038)]. When combined with traditional clinical variables, abnormal GLS remained independently predictive of the primary outcome [multivariate Hazard ratio 5.31 (95 % confidence interval 1.18-24, p = 0.030)]. In a model including the strongest clinical and echocardiographic predictors of the primary outcome, abnormal GLS demonstrated significant incremental benefit for risk stratification [net reclassification improvement 0.75 (95 % confidence interval 0.21-1.23, p < 0.0001)]. Abnormal GLS is an independent predictor of adverse outcomes in HCM patients. Standardized use of GLS may provide significant incremental value over traditional variables for risk stratification.
Reference values of bone stiffness index and C-terminal telopeptide in healthy European children.
Herrmann, D; Intemann, T; Lauria, F; Mårild, S; Molnár, D; Moreno, L A; Sioen, I; Tornaritis, M; Veidebaum, T; Pigeot, I; Ahrens, W
2014-09-01
Quantitative ultrasound measurements and bone metabolic markers can help to monitor bone health and to detect impaired skeletal development. Population-based reference values for children may serve as a basis for preventive measures to reduce the risk of osteoporosis and osteoporotic fractures in later life. This is the first paper providing age-, sex- and height-specific reference values for bone stiffness index (SI) and serum carboxy-terminal cross-linking telopeptide of type I collagen (CTX) in healthy, apparently prepubertal children. In the population-based IDEFICS baseline survey (2007-2008) and follow-up (2009-2010), 18,745 children from eight European countries were newly recruited. A total of 10,791 2-10.9-year-old and 1646 3-8.9-year-old healthy children provided data on SI of the right and left calcaneus and serum CTX, respectively. Furthermore, height and weight were measured. Percentile curves were calculated using the General Additive Model for Location Scale and Shape (GAMLSS) to model the distribution of SI and CTX depending on multiple covariates while accounting for dispersion, skewness, and the kurtosis of this distribution. SI was negatively associated with age and height in children aged 2-5 years, whereas a positive association was observed in children aged 6-10 years. The dip in SI occurred at older age for higher SI percentiles and was observed earlier in taller children than in smaller children. The CTX reference curves showed a linear-positive association with age and height. No major sex differences were observed for the SI and CTX reference values. These reference data lay the ground to evaluate bone growth and metabolism in prepubertal children in epidemiological and clinical settings. They may also inform clinical practice to monitor skeletal development and to assess adverse drug reactions during medical treatments.
Glycaemic index and glycaemic load values of a selection of popular foods consumed in Hong Kong.
Lok, Kris Y; Chan, Ruth; Chan, Dicken; Li, Liz; Leung, Grace; Woo, Jean; Lightowler, Helen J; Henry, C Jeya K
2010-02-01
The objective of the present paper is to provide glycaemic index (GI) and glycaemic load (GL) values for a variety of foods that are commonly consumed in Hong Kong and expand on the international GI table of Chinese foods. Fasted healthy subjects were given 50 g of available carbohydrate servings of a glucose reference, which was tested twice, and test foods of various brands of noodles (n 5), instant cereals (n 3) and breads (n 2), which were tested once, on separate occasions. For each test food, tests were repeated in ten healthy subjects. Capillary blood glucose was measured via finger-prick samples in fasting subjects ( - 5, 0 min) and at 15, 30, 45, 60, 90 and 120 min after the consumption of each test food. The GI of each test food was calculated geometrically by expressing the incremental area under the blood glucose response curve (IAUC) of each test food as a percentage of each subject's average IAUC for the reference food. GL was calculated as the product of the test food's GI and the amount of available carbohydrate in a reference serving size. The majority of GI values of foods tested were medium (a GI value of 56-69) to high (a GI value of 70 or more) and compared well with previously published values. More importantly, our dataset provides GI values of ten foods previously untested and presents values for foods commonly consumed in Hong Kong.
Wang, Hui; Wang, Yiping; Zhou, Zhenwei; Wang, Shuo; Yin, Hongyin; Xie, Keqin
2015-06-01
To determine the normal reference value of pyrrole adducts in urine in young people in a university in Shandong, China, and to provide a reliable basis for the clinical diagnosis of n-hexane poisoning. A total of 240 college students were randomly selected. After excluding 32 ineligible students, 208 subjects were included in this study, consisting of 104 males and 104 females, with a mean age of 21?3 years (range: 18 to 24 years). Morning urine was collected from each subject. The content of pyrrole adducts was determined by chromatometry. The content of pyrrole adducts in both male and female obeyed a positively skewed distribution. The median level of pyrrole adducts in male subjects was 0.88 nmol/ml, and the reference value was 0.14-3.92 nmol/ml. The median level of pyrrole adducts in female subjects was 0.93 nmol/ ml, and the reference value was 0.09-3.27 nmol/ml. Student's t test identified no statistical difference in pyrrole adduct level between male and female subjects (t=0.15, P>0.05). The median level of pyrrole adducts in normal young people is 0.91 nmol/ml, and the reference value is 0.11-3.95 nmol/ml.
A cascade feedback control approach for hypnosis.
Puebla, Hector; Alvarez-Ramírez, José
2005-10-01
This article studies the problem of controlling the drug administration during an anesthesia process, where muscle relaxation, analgesia, and hypnosis are regulated by means of monitored administration of specific drugs. On the basis of a seventh-order nonlinear pharmacokinetic-pharmacodynamic representation of the hypnosis process dynamics, a cascade (master/slave) feedback control structure for controlling the bispectral index (BIS) is proposed. The master controller compares the measured BIS with its reference value to provide the expired isoflurane concentration reference to the slave controller. In turn, the slave controller manipulates the anesthetic isoflurane concentration entering the anesthetic system to achieve the reference from the master controller. The advantage of the proposed cascade control structure with respect to its noncascade counterpart is that the former provides operation protection against BIS measurement failures. In fact, under a BIS measurement fault, the master control feedback is broken and the slave controller operates under a safe reference value. Extensive numerical simulations are used to illustrate the functioning of the proposed cascade control structure.
Reference value of impulse oscillometry in taiwanese preschool children.
Lai, Shen-Hao; Yao, Tsung-Chieh; Liao, Sui-Ling; Tsai, Ming-Han; Hua, Men-Chin; Yeh, Kuo-Wei; Huang, Jing-Long
2015-06-01
Impulse oscillometry is a potential technique for assessing the respiratory mechanism-which includes airway resistance and reactance during tidal breathing-in minimally cooperative young children. The reference values available in Asian preschool children are limited, especially in children of Chinese ethnicity. This study aimed to develop reference equations for lung function measurements using impulse oscillometry in Taiwanese children for future clinical application and research exploitation. Impulse oscillometry was performed in 150 healthy Taiwanese children (aged 2-6 years) to measure airway resistance and reactance at various frequencies. We used regression analysis to generate predictive equations separately by age, body height, body weight, and gender. The stepwise regression model revealed that body height was the most significant determinant of airway resistance and reactance in preschool young children. With the growth in height, a decrease in airway resistance and a paradoxical increase in reactance occurred at different frequencies. The regression curve of resistance at 5 Hz was comparable to previous reference values. This study provided reference values for several variables of the impulse oscillometry measurements in healthy Taiwanese children aged 2-6 years. With these reference data, clinical application of impulse oscillometry would be expedient in diagnosing respiratory diseases in preschool children. Copyright © 2014. Published by Elsevier B.V.
Turk, Gregory C; Sharpless, Katherine E; Cleveland, Danielle; Jongsma, Candice; Mackey, Elizabeth A; Marlow, Anthony F; Oflaz, Rabia; Paul, Rick L; Sieber, John R; Thompson, Robert Q; Wood, Laura J; Yu, Lee L; Zeisler, Rolf; Wise, Stephen A; Yen, James H; Christopher, Steven J; Day, Russell D; Long, Stephen E; Greene, Ella; Harnly, James; Ho, I-Pin; Betz, Joseph M
2013-01-01
Standard Reference Material 3280 Multivitamin/ Multielement Tablets was issued by the National Institute of Standards and Technology in 2009, and has certified and reference mass fraction values for 13 vitamins, 26 elements, and two carotenoids. Elements were measured using two or more analytical methods at NIST with additional data contributed by collaborating laboratories. This reference material is expected to serve a dual purpose: to provide quality assurance in support of a database of dietary supplement products and to provide a means for analysts, dietary supplement manufacturers, and researchers to assess the appropriateness and validity of their analytical methods and the accuracy of their results.
Adjustable electronic load-alarm relay
Mason, Charles H.; Sitton, Roy S.
1976-01-01
This invention is an improved electronic alarm relay for monitoring the current drawn by an AC motor or other electrical load. The circuit is designed to measure the load with high accuracy and to have excellent alarm repeatability. Chattering and arcing of the relay contacts are minimal. The operator can adjust the set point easily and can re-set both the high and the low alarm points by means of one simple adjustment. The relay includes means for generating a signal voltage proportional to the motor current. In a preferred form of the invention a first operational amplifier is provided to generate a first constant reference voltage which is higher than a preselected value of the signal voltage. A second operational amplifier is provided to generate a second constant reference voltage which is lower than the aforementioned preselected value of the signal voltage. A circuit comprising a first resistor serially connected to a second resistor is connected across the outputs of the first and second amplifiers, and the junction of the two resistors is connected to the inverting terminal of the second amplifier. Means are provided to compare the aforementioned signal voltage with both the first and second reference voltages and to actuate an alarm if the signal voltage is higher than the first reference voltage or lower than the second reference voltage.
[Reference values of proteins for the Venezuelan population].
Guerra, Marisa; Hernández, María N; López, Michelle; Alfaro, María J
2013-12-01
This study presents the reference values for protein requirements. The consumption of the Venezuelan population was obtained according to the Food Consumption Monitoring Survey (ESCA) 2010-2012. The diet provided good quality proteins, combining animal and vegetable foods in an approximate ratio of 1:1. The reference values were calculated based on the safe levels of protein intake recommended by WHO/FAO/UN 2007, with an adjustment for protein supply depending on age, weight, and contribution to the caloric formula of proteins for light physical activity. The reference values for protein requirements recommended as safe levels of intake in g/kg/day are 1.14 to 1.80 for males and females less than one-year-old, from 1 to 3 years, 0.90 to 1.14; from 4 to 6 years old, 0.86 to 0.89; and from 7 to 10 years old, 0.91 to 0.92. For adolescents, the average is 0.88 and 1.07 for males and females, respectively. In adults from 20 to 59 years old, 0.83 for men and women is recommended, and for older adults, 1.00 for men and women. In pregnant women, additional consumptions are recommended according to gestation time. Adolescent pregnant women must consume additional 1.2 to 1.7 g/kg/day to normal requirement. In breastfeeding women, the values differ between the first six months postnatal period and after six months of breastfeeding. The reference values for protein in this update were lower than the values of the 2000 version.
Lorenz, Jennifer M.; Qi, Haiping; Coplen, Tyler B.
2017-01-01
As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from ice-core water from the Amundsen–Scott South Pole Station. This isotopic reference material, designated as USGS49, was filtered, homogenised, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity and measured by dual-inlet isotope-ratio mass spectrometry. The δ2H and δ18O values of USGS49 are −394.7 ± 0.4 and −50.55 ± 0.04 mUr (where mUr = 0.001 = ‰), respectively, relative to VSMOW, on scales normalised such that the δ2H and δ18O values of SLAP reference water are, respectively, −428 and −55.5 mUr. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95% probability of encompassing the true value. This isotopic reference material is intended as one of two isotopic reference waters for daily normalisation of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer. It is available by the case of 144 glass ampoules or as a set of sixteen glass ampoules containing 5 ml of water in each ampoule.
Lemaillet, Paul; Bouchard, Jean-Pierre; Allen, David W
2015-07-01
The development of a national reference instrument dedicated to the measurement of the scattering and absorption properties of solid tissue-mimicking phantoms used as reference standards is presented. The optical properties of the phantoms are measured with a double-integrating sphere setup in the steady-state domain, coupled with an inversion routine of the adding-doubling procedure that allows for the computation of the uncertainty budget for the measurements. The results are compared to the phantom manufacturer's values obtained by a time-resolved approach. The results suggest that the agreement between these two independent methods is within the estimated uncertainties. This new reference instrument will provide optical biomedical research laboratories with reference values for absolute diffuse optical properties of phantom materials.
Thomas, Jeanice B; Duewer, David L; Mugenya, Isaac O; Phinney, Karen W; Sander, Lane C; Sharpless, Katherine E; Sniegoski, Lorna T; Tai, Susan S; Welch, Michael J; Yen, James H
2012-01-01
Standard Reference Material 968e Fat-Soluble Vitamins, Carotenoids, and Cholesterol in Human Serum provides certified values for total retinol, γ- and α-tocopherol, total lutein, total zeaxanthin, total β-cryptoxanthin, total β-carotene, 25-hydroxyvitamin D(3), and cholesterol. Reference and information values are also reported for nine additional compounds including total α-cryptoxanthin, trans- and total lycopene, total α-carotene, trans-β-carotene, and coenzyme Q(10). The certified values for the fat-soluble vitamins and carotenoids in SRM 968e were based on the agreement of results from the means of two liquid chromatographic methods used at the National Institute of Standards and Technology (NIST) and from the median of results of an interlaboratory comparison exercise among institutions that participate in the NIST Micronutrients Measurement Quality Assurance Program. The assigned values for cholesterol and 25-hydroxyvitamin D(3) in the SRM are the means of results obtained using the NIST reference method based upon gas chromatography-isotope dilution mass spectrometry and liquid chromatography-isotope dilution tandem mass spectrometry, respectively. SRM 968e is currently one of two available health-related NIST reference materials with concentration values assigned for selected fat-soluble vitamins, carotenoids, and cholesterol in human serum matrix. This SRM is used extensively by laboratories worldwide primarily to validate methods for determining these analytes in human serum and plasma and for assigning values to in-house control materials. The value assignment of the analytes in this SRM will help support measurement accuracy and traceability for laboratories performing health-related measurements in the clinical and nutritional communities.
Aylward, Lesa L; Kirman, Chris R; Blount, Ben C; Hays, Sean M
2010-10-01
The National Health and Nutrition Examination Survey (NHANES) generates population-representative biomonitoring data for many chemicals including volatile organic compounds (VOCs) in blood. However, no health or risk-based screening values are available to evaluate these data from a health safety perspective or to use in prioritizing among chemicals for possible risk management actions. We gathered existing risk assessment-based chronic exposure reference values such as reference doses (RfDs), reference concentrations (RfCs), tolerable daily intakes (TDIs), cancer slope factors, etc. and key pharmacokinetic model parameters for 47 VOCs. Using steady-state solutions to a generic physiologically-based pharmacokinetic (PBPK) model structure, we estimated chemical-specific steady-state venous blood concentrations across chemicals associated with unit oral and inhalation exposure rates and with chronic exposure at the identified exposure reference values. The geometric means of the slopes relating modeled steady-state blood concentrations to steady-state exposure to a unit oral dose or unit inhalation concentration among 38 compounds with available pharmacokinetic parameters were 12.0 microg/L per mg/kg-d (geometric standard deviation [GSD] of 3.2) and 3.2 microg/L per mg/m(3) (GSD=1.7), respectively. Chemical-specific blood concentration screening values based on non-cancer reference values for both oral and inhalation exposure range from 0.0005 to 100 microg/L; blood concentrations associated with cancer risk-specific doses at the 1E-05 risk level ranged from 5E-06 to 6E-02 microg/L. The distribution of modeled steady-state blood concentrations associated with unit exposure levels across VOCs may provide a basis for estimating blood concentration screening values for VOCs that lack chemical-specific pharmacokinetic data. The screening blood concentrations presented here provide a tool for risk assessment-based evaluation of population biomonitoring data for VOCs and are most appropriately applied to central tendency estimates for such datasets. Copyright (c) 2010 Elsevier Inc. All rights reserved.
Values Strategies for Classroom Teachers.
ERIC Educational Resources Information Center
Lemin, Marion, Ed.; And Others
This document is a reference for teachers to use in incorporating values education into all subject areas through the activities listed in the book. The book contains 16 chapters, of which about half provide guidelines, discussion and activities related to values in general, and half suggest activities specific to individual areas of study. In the…
77 FR 2829 - Energy Conservation Program: Test Procedure for Television Sets
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-19
... provisions designed to improve energy efficiency. (All references to EPCA refer to the statute as amended... also provides that the test procedure shall be reasonably designed to produce test results which... facility one is denoted with numerical values, while the data from test facility two is denoted with...
Lorenz, Jennifer M; Tarbox, Lauren; Buck, Bryan; Qi, Haiping; Coplen, Tyler B
2014-10-15
As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from drinking water collected from the Biscayne aquifer in Ft. Lauderdale, Florida. This isotopic reference water was filtered, homogenized, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and measured by dual-inlet isotope-ratio mass spectrometry. This reference material is available by the case of 144 glass ampoules containing either 4 mL or 5 mL of water in each ampoule. The δ(2)H and δ(18)O values of this reference material are -10.3 ± 0.4‰ and -2.238 ± 0.011‰, respectively, relative to VSMOW, on scales normalized such that the δ(2)H and δ(18)O values of SLAP reference water are, respectively, -428 and -55.5‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc ) about the reference value that provides an interval that has about a 95% probability of encompassing the true value. This isotopic reference material, designated as USGS45, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA.
Creatine and guanidinoacetate reference values in a French population.
Joncquel-Chevalier Curt, Marie; Cheillan, David; Briand, Gilbert; Salomons, Gajja S; Mention-Mulliez, Karine; Dobbelaere, Dries; Cuisset, Jean-Marie; Lion-François, Laurence; Des Portes, Vincent; Chabli, Allel; Valayannopoulos, Vassili; Benoist, Jean-François; Pinard, Jean-Marc; Simard, Gilles; Douay, Olivier; Deiva, Kumaran; Tardieu, Marc; Afenjar, Alexandra; Héron, Delphine; Rivier, François; Chabrol, Brigitte; Prieur, Fabienne; Cartault, François; Pitelet, Gaëlle; Goldenberg, Alice; Bekri, Soumeya; Gerard, Marion; Delorme, Richard; Porchet, Nicole; Vianey-Saban, Christine; Vamecq, Joseph
2013-11-01
Creatine and guanidinoacetate are biomarkers of creatine metabolism. Their assays in body fluids may be used for detecting patients with primary creatine deficiency disorders (PCDD), a class of inherited diseases. Their laboratory values in blood and urine may vary with age, requiring that reference normal values are given within the age range. Despite the long known role of creatine for muscle physiology, muscle signs are not necessarily the major complaint expressed by PCDD patients. These disorders drastically affect brain function inducing, in patients, intellectual disability, autistic behavior and other neurological signs (delays in speech and language, epilepsy, ataxia, dystonia and choreoathetosis), being a common feature the drop in brain creatine content. For this reason, screening of PCDD patients has been repeatedly carried out in populations with neurological signs. This report is aimed at providing reference laboratory values and related age ranges found for a large scale population of patients with neurological signs (more than 6 thousand patients) previously serving as a background population for screening French patients with PCDD. These reference laboratory values and age ranges compare rather favorably with literature values for healthy populations. Some differences are also observed, and female participants are discriminated from male participants as regards to urine but not blood values including creatine on creatinine ratio and guanidinoacetate on creatinine ratio values. Such gender differences were previously observed in healthy populations; they might be explained by literature differential effects of testosterone and estrogen in adolescents and adults, and by estrogen effects in prepubertal age on SLC6A8 function. Finally, though they were acquired on a population with neurological signs, the present data might reasonably serve as reference laboratory values in any future medical study exploring abnormalities of creatine metabolism and transport. © 2013 Elsevier Inc. All rights reserved.
Canine and feline hematology reference values for the ADVIA 120 hematology system.
Moritz, Andreas; Fickenscher, Yvonne; Meyer, Karin; Failing, Klaus; Weiss, Douglas J
2004-01-01
The ADVIA 120 is a laser-based hematology analyzer with software applications for animal species. Accurate reference values would be useful for the assessment of new hematologic parameters and for interlaboratory comparisons. The goal of this study was to establish reference intervals for CBC results and new parameters for RBC morphology, reticulocytes, and platelets in healthy dogs and cats using the ADVIA 120 hematology system. The ADVIA 120, with multispecies software (version 1.107-MS), was used to analyze whole blood samples from clinically healthy dogs (n=46) and cats (n=61). Data distribution was determined and reference intervals were calculated as 2.5 to 97.5 percentiles and 25 to 75 percentiles. Most data showed Gaussian or log-normal distribution. The numbers of RBCs falling outside the normocytic-normochromic range were slightly higher in cats than in dogs. Both dogs and cats had reticulocytes with low, medium, and high absorbance. Mean numbers of large platelets and platelet clumps were higher in cats compared with dogs. Reference intervals obtained on the ADVIA 120 provide valuable baseline information for assessing new hematologic parameters and for interlaboratory comparisons. Differences compared with previously published reference values can be attributed largely to differences in methodology.
Fox, Carrie; Bernardino, Lourdes; Cochran, Jill; Essig, Mary; Bridges, Kristie Grove
2017-11-01
Assessing pediatric patients for insulin resistance is one way to identify those who are at a high risk of developing type 2 diabetes mellitus. The homoeostasis model assessment (HOMA) is a measure of insulin resistance based on fasting blood glucose and insulin levels. Although this measure is widely used in research, cutoff values for pediatric populations have not been established. To assess the validity of HOMA cutoff values used in pediatric studies published in peer-reviewed journals. Studies published from January 2010 to December 2015 were identified through MEDLINE. Initial screening of abstracts was done to select studies that were conducted in pediatric populations and used HOMA to assess insulin resistance. Subsequent full-text review narrowed the list to only those studies that used a specific HOMA score to diagnose insulin resistance. Each study was classified as using a predetermined fixed HOMA cutoff value or a cutoff that was a percentile specific to that population. For studies that used a predetermined cutoff value, the references cited to provide evidence in support of that cutoff were evaluated. In the 298 articles analyzed, 51 different HOMA cutoff values were used to classify patients as having insulin resistance. Two hundred fifty-five studies (85.6%) used a predetermined fixed cutoff value, but only 72 (28.2%) of those studies provided a reference that supported its use. One hundred ten studies (43%) that used a fixed cutoff either cited a study that did not mention HOMA or provided no reference at all. Tracing of citation history indicated that the most commonly used cutoff values were ultimately based on studies that did not validate their use for defining insulin resistance. Little evidence exists to support HOMA cutoff values commonly used to define insulin resistance in pediatric studies. These findings highlight the importance of validating study design elements when training medical students and novice investigators. Using available data to generate population ranges for HOMA would improve its clinical utility.
Four dimensional studies in earth space
NASA Technical Reports Server (NTRS)
Mather, R. S.
1972-01-01
A system of reference which is directly related to observations, is proposed for four-dimensional studies in earth space. Global control network and polar wandering are defined. The determination of variations in the earth's gravitational field with time also forms part of such a system. Techniques are outlined for the unique definition of the motion of the geocenter, and the changes in the location of the axis of rotation of an instantaneous earth model, in relation to values at some epoch of reference. The instantaneous system referred to is directly related to a fundamental equation in geodynamics. The reference system defined would provide an unambiguous frame for long period studies in earth space, provided the scale of the space were specified.
Reference values of aortic pulse wave velocity in the elderly.
Alecu, Cosmin; Labat, Carlos; Kearney-Schwartz, Anna; Fay, Renaud; Salvi, Paolo; Joly, Laure; Lacolley, Patrick; Vespignani, Hervé; Benetos, Athanase
2008-11-01
Increased aortic pulse wave velocity (AoPWV) is an independent predictor of cardiovascular morbidity and mortality. There are, however, no generally accepted limits for defining the normal or reference values. The aim of the present study was to define reference values for AoPWV. AoPWV was assessed using applanation tonometry (PulsePen device) in a community living ambulatory population of 455 individuals aged 60-75 years. AoPWV was studied in a group of 206 individuals without hypertension or diabetes, called the 'reference-values group' (RVG), and in a group of 249 individuals with hypertension or diabetes, called the hypertension-diabetes group (HDG). The 95th percentile of the samples was used to determine the upper limit of AoPWV reference values. Mean AoPWV was 8.7+/-2.3 m/s in the RVG and 10.2+/-2.5 m/s in the hypertension-diabetes group (P<0.0001). In the RVG, median AoPWV in the three age subgroups was 8.0 m/s (7.6-8.5) in the 60-64-, 8.0 m/s (7.5-9.0) in the 65-69- and 9.0 m/s (7.9-9.5) in the 70-75-year-old group (NS among groups). In the entire RVG, the upper bounds of the 75th and the 95th percentile of the sample's AoPWV were 10 and 13 m/s, respectively, with no difference between sexes. In elderly individuals of 60-75 years, an AoPWV value below 10 m/s, measured with the PulsePen device, can be considered as a normal value. Values of 10-13 m/s can be considered as 'high normal' or 'borderline', whereas an AoPWV above 13 m/s is frankly elevated. This study provides, for the first time in the elderly, reference values of AoPWV.
Nocturnal oxygen saturation profiles of healthy term infants
Terrill, Philip Ian; Dakin, Carolyn; Hughes, Ian; Yuill, Maggie; Parsley, Chloe
2015-01-01
Objective Pulse oximetry is used extensively in hospital and home settings to measure arterial oxygen saturation (SpO2). Interpretation of the trend and range of SpO2 values observed in infants is currently limited by a lack of reference ranges using current devices, and may be augmented by development of cumulative frequency (CF) reference-curves. This study aims to provide reference oxygen saturation values from a prospective longitudinal cohort of healthy infants. Design Prospective longitudinal cohort study. Setting Sleep-laboratory. Patients 34 healthy term infants were enrolled, and studied at 2 weeks, 3, 6, 12 and 24 months of age (N=30, 25, 27, 26, 20, respectively). Interventions Full overnight polysomnography, including 2 s averaging pulse oximetry (Masimo Radical). Main outcome measurements Summary SpO2 statistics (mean, median, 5th and 10th percentiles) and SpO2 CF plots were calculated for each recording. CF reference-curves were then generated for each study age. Analyses were repeated with sleep-state stratifications and inclusion of manual artefact removal. Results Median nocturnal SpO2 values ranged between 98% and 99% over the first 2 years of life and the CF reference-curves shift right by 1% between 2 weeks and 3 months. CF reference-curves did not change with manual artefact removal during sleep and did not vary between rapid eye movement (REM) and non-REM sleep. Manual artefact removal did significantly change summary statistics and CF reference-curves during wake. Conclusions SpO2 CF curves provide an intuitive visual tool for evaluating whether an individual's nocturnal SpO2 distribution falls within the range of healthy age-matched infants, thereby complementing summary statistics in the interpretation of extended oximetry recordings in infants. PMID:25063836
Reference values of clinical chemistry and hematology parameters in rhesus monkeys (Macaca mulatta).
Chen, Younan; Qin, Shengfang; Ding, Yang; Wei, Lingling; Zhang, Jie; Li, Hongxia; Bu, Hong; Lu, Yanrong; Cheng, Jingqiu
2009-01-01
Rhesus monkey models are valuable to the studies of human biology. Reference values for clinical chemistry and hematology parameters of rhesus monkeys are required for proper data interpretation. Whole blood was collected from 36 healthy Chinese rhesus monkeys (Macaca mulatta) of either sex, 3 to 5 yr old. Routine chemistry and hematology parameters, and some special coagulation parameters including thromboelastograph and activities of coagulation factors were tested. We presented here the baseline values of clinical chemistry and hematology parameters in normal Chinese rhesus monkeys. These data may provide valuable information for veterinarians and investigators using rhesus monkeys in experimental studies.
An Evaluation Framework for Lossy Compression of Genome Sequencing Quality Values.
Alberti, Claudio; Daniels, Noah; Hernaez, Mikel; Voges, Jan; Goldfeder, Rachel L; Hernandez-Lopez, Ana A; Mattavelli, Marco; Berger, Bonnie
2016-01-01
This paper provides the specification and an initial validation of an evaluation framework for the comparison of lossy compressors of genome sequencing quality values. The goal is to define reference data, test sets, tools and metrics that shall be used to evaluate the impact of lossy compression of quality values on human genome variant calling. The functionality of the framework is validated referring to two state-of-the-art genomic compressors. This work has been spurred by the current activity within the ISO/IEC SC29/WG11 technical committee (a.k.a. MPEG), which is investigating the possibility of starting a standardization activity for genomic information representation.
Guo, Ying; Du, Xiang-Yang; Huang, Hua-Lan; Wang, Wei-Qing; Nie, Xin; Li, Gui-Xing
2017-11-01
To establish the reference value of high sensitive cardiac troponin T (hs-cTnT) and the efficiency of reference value in the diagnosis of chest pain. Volunteers from eight independent communities in Chengdu,Sichuan were selected with detailed records of physical examination,electrocardiogram,ultrasound examination. The level of hs-cTnT for healthy volunteers was tested to determine ninety-ninth percentile references according to sex and ages. 2 249 patients with chest pain in the emergency department of Western China Hospital from July 2009 to July 2014 were enrolled to measure the efficiency of reference value for diagnosing acute myocardial infarction (AMI). There were 1 305 volunteers included finally. Among them,the mean hs-cTnT level of male was 4.3 (3.2-5.9) ng/L,which was significantly higher than that of female 3.0 (3.0-3.1) ng/L ( P <0.01) . The correlation coefficient between age and hs-cTnT level was 0.43 (male) and 0.29 (female),and the P -value was less than 0.01. The 99th percentile values of male were 10.8 ng/L,15.4 ng/L and 19.7 ng/L for <45 yr.,45-<60 yr. and ≥60 yr.,respectively. Those values of female were 4.6 ng/L,8.9 ng/L,18.8 ng/L,respectively. There was no difference in sensitivity and specificity between the value we figured out and manufactures provided (14.0 ng/L) for those<60 yr.. For the patients ≥60 yr.,the sensitivity and negative predictive value did not show diversity ( P >0.05) but the specificity and positive predictive value showed significant difference (male: 0.67 vs. 0.56 and 0.83 vs. 0.79, P <0.05;female:0.75 vs. 0.68 and 0.74 vs. 0.69, P <0.05). We recommends that the ninety-ninth percentile reference value of patients<60 yr. should be 14.0 ng/L,while 20.0 ng/L for those patients≥60 yr.
Enhance the Value of a Research Paper: Choosing the Right References and Writing them Accurately.
Bavdekar, Sandeep B
2016-03-01
References help readers identify and locate sources used for justifying the need for conducting the research study, verify methods employed in the study and for discussing the interpretation of results and implications of the study. It is extremely essential that references are accurate and complete. This article provides suggestions regarding choosing references and writing reference list. References are a list of sources that are selected by authors to represent the best documents concerning the research study.1 They constitute the foundation of any research paper. Although generally written towards the end of the article-writing process, they are nevertheless extremely important. They provide the context for the hypothesis and help justify the need for conducting the research study. Authors use references to inform readers about the techniques used for conducting the study and convince them about the appropriateness of methodology used. References help provide appropriate perspective in which the research findings should be seen and interpreted. This communication will discuss the purpose of citations, how to select quality sources for citing and the importance of accuracy while writing the reference list. © Journal of the Association of Physicians of India 2011.
Zhi, Ruicong; Zhao, Lei; Xie, Nan; Wang, Houyin; Shi, Bolin; Shi, Jingye
2016-01-13
A framework of establishing standard reference scale (texture) is proposed by multivariate statistical analysis according to instrumental measurement and sensory evaluation. Multivariate statistical analysis is conducted to rapidly select typical reference samples with characteristics of universality, representativeness, stability, substitutability, and traceability. The reasonableness of the framework method is verified by establishing standard reference scale of texture attribute (hardness) with Chinese well-known food. More than 100 food products in 16 categories were tested using instrumental measurement (TPA test), and the result was analyzed with clustering analysis, principal component analysis, relative standard deviation, and analysis of variance. As a result, nine kinds of foods were determined to construct the hardness standard reference scale. The results indicate that the regression coefficient between the estimated sensory value and the instrumentally measured value is significant (R(2) = 0.9765), which fits well with Stevens's theory. The research provides reliable a theoretical basis and practical guide for quantitative standard reference scale establishment on food texture characteristics.
Dosimetry and image quality assessment in a direct radiography system
Oliveira, Bruno Beraldo; de Oliveira, Marcio Alves; Paixão, Lucas; Teixeira, Maria Helena Araújo; Nogueira, Maria do Socorro
2014-01-01
Objective To evaluate the mean glandular dose with a solid state detector and the image quality in a direct radiography system, utilizing phantoms. Materials and Methods Irradiations were performed with automatic exposure control and polymethyl methacrylate slabs with different thicknesses to calculate glandular dose values. The image quality was evaluated by means of the structures visualized on the images of the phantoms. Results Considering the uncertainty of the measurements, the mean glandular dose results are in agreement with the values provided by the equipment and with internationally adopted reference levels. Results obtained from images of the phantoms were in agreement with the reference values. Conclusion The present study contributes to verify the equipment conformity as regards dose values and image quality. PMID:25741119
Millán, Javier; Chirife, Andrea D; Altet, Laura
2015-03-01
The role of wildlife in the epidemiology of leishmaniosis in under debate, and determining whether infection with Leishmania infantum causes illness in wild carnivores is important to determine its potential role as a reservoir. To provide for the first time serum biochemistry reference values for the common genet (Genetta genetta), and to determine variations associated with L. infantum infection. Twenty-five serum biochemistry parameters were determined in 22 wild-caught genets. Blood samples were analyzed for L. infantum DNA by means of real-time polymerase chain reaction (PCR). Two female genets were positive for L. infantum DNA but did not show any external clinical sign upon physical examination. Among other variations in the biochemistry values of these genets, one presented a higher concentration of gamma-globulins and cholesterol, whereas the other genet presented increased creatinine, bilirubin, and chloride levels when compared to uninfected females. Sex-related differences in some parameters were also reported. Infection with L. infantum may sometimes be accompanied by abnormal serum biochemistry in wild carnivores. Clinical disease may occur in L. infantum-infected wild carnivores. This has implications in the epidemiology of leishmaniosis. In addition, the data provided here would also be useful as reference values for researchers or rehabilitators working with the common genet.
Imboden, Mary T; Welch, Whitney A; Swartz, Ann M; Montoye, Alexander H K; Finch, Holmes W; Harber, Matthew P; Kaminsky, Leonard A
2017-01-01
Dual energy x-ray absorptiometry (DXA) is an established technique for the measurement of body composition. Reference values for these variables, particularly those related to fat mass, are necessary for interpretation and accurate classification of those at risk for obesity-related health complications and in need of lifestyle modifications (diet, physical activity, etc.). Currently, there are no reference values available for GE-Healthcare DXA systems and it is known that whole-body and regional fat mass measures differ by DXA manufacturer. To develop reference values by age and sex for DXA-derived fat mass measurements with GE-Healthcare systems. A de-identified sample of 3,327 participants (2,076 women, 1,251 men) was obtained from Ball State University's Clinical Exercise Physiology Laboratory and University of Wisconsin-Milwaukee's Physical Activity & Health Research Laboratory. All scans were completed using a GE Lunar Prodigy or iDXA and data reported included percent body fat (%BF), fat mass index (FMI), and ratios of android-to-gynoid (A/G), trunk/limb, and trunk/leg fat measurements. Percentiles were calculated and a factorial ANOVA was used to determine differences in the mean values for each variable between age and sex. Normative reference values for fat mass variables from DXA measurements obtained from GE-Healthcare DXA systems are presented as percentiles for both women and men in 10-year age groups. Women had higher (p<0.01) mean %BF and FMI than men, whereas men had higher (p<0.01) mean ratios of A/G, trunk/limb, and trunk/leg fat measurements than women. These reference values provide clinicians and researchers with a resource for interpretation of DXA-derived fat mass measurements specific to use with GE-Healthcare DXA systems.
Accuracy of Referring Provider and Endoscopist Impressions of Colonoscopy Indication.
Naveed, Mariam; Clary, Meredith; Ahn, Chul; Kubiliun, Nisa; Agrawal, Deepak; Cryer, Byron; Murphy, Caitlin; Singal, Amit G
2017-07-01
Background: Referring provider and endoscopist impressions of colonoscopy indication are used for clinical care, reimbursement, and quality reporting decisions; however, the accuracy of these impressions is unknown. This study assessed the sensitivity, specificity, positive and negative predictive value, and overall accuracy of methods to classify colonoscopy indication, including referring provider impression, endoscopist impression, and administrative algorithm compared with gold standard chart review. Methods: We randomly sampled 400 patients undergoing a colonoscopy at a Veterans Affairs health system between January 2010 and December 2010. Referring provider and endoscopist impressions of colonoscopy indication were compared with gold-standard chart review. Indications were classified into 4 mutually exclusive categories: diagnostic, surveillance, high-risk screening, or average-risk screening. Results: Of 400 colonoscopies, 26% were performed for average-risk screening, 7% for high-risk screening, 26% for surveillance, and 41% for diagnostic indications. Accuracy of referring provider and endoscopist impressions of colonoscopy indication were 87% and 84%, respectively, which were significantly higher than that of the administrative algorithm (45%; P <.001 for both). There was substantial agreement between endoscopist and referring provider impressions (κ=0.76). All 3 methods showed high sensitivity (>90%) for determining screening (vs nonscreening) indication, but specificity of the administrative algorithm was lower (40.3%) compared with referring provider (93.7%) and endoscopist (84.0%) impressions. Accuracy of endoscopist, but not referring provider, impression was lower in patients with a family history of colon cancer than in those without (65% vs 84%; P =.001). Conclusions: Referring provider and endoscopist impressions of colonoscopy indication are both accurate and may be useful data to incorporate into algorithms classifying colonoscopy indication. Copyright © 2017 by the National Comprehensive Cancer Network.
2003-01-01
Data are not readily available on the accuracy of one of the most commonly used home blood glucose meters, the One Touch Ultra (LifeScan, Milpitas, California). The purpose of this report is to provide information on the accuracy of this home glucose meter in children with type 1 diabetes. During a 24-h clinical research center stay, the accuracy of the Ultra meter was assessed in 91 children, 3-17 years old, with type 1 diabetes by comparing the Ultra glucose values with concurrent reference serum glucose values measured in a central laboratory. The Pearson correlation between the 2,068 paired Ultra and reference values was 0.97, with the median relative absolute difference being 6%. Ninety-four percent of all Ultra values (96% of venous and 84% of capillary samples) met the proposed International Organisation for Standardisation (ISO) standard for instruments used for self-monitoring of glucose when compared with venous reference values. Ninety-nine percent of values were in zones A + B of the Modified Error Grid. A high degree of accuracy was seen across the full range of glucose values. For 353 data points during an insulin-induced hypoglycemia test, the Ultra meter was found to have accuracy that was comparable to concurrently used benchmark instruments (Beckman, YSI, or i-STAT); 95% and 96% of readings from the Ultra meter and the benchmark instruments met the proposed ISO criteria, respectively. These results confirm that the One Touch Ultra meter provides accurate glucose measurements for both hypoglycemia and hyperglycemia in children with type 1 diabetes.
Rogers, Linda B; Kaack, M Bernice; Henson, Michael C; Rasmussen, Terri; Henson, Elizabeth; Veazey, Ronald S; Krogstad, Donald J; Davison, Billie B
2005-06-01
Hematology and flow cytometry reference values for rhesus umbilical cord blood (UCB) were established in 17 healthy infant rhesus monkeys delivered by elective cesarean section 10 days preterm. The infants were born to age matched, singly caged primigravid or secundigravid dams. The hematology and flow cytometry values were determined by automated cell counter and by FACS. No significant differences were observed with respect to infant gender. With respect to gravida, the primigravid infants had a significantly higher percentage (P= 0.05) of CD20(+) B lymphocytes in UCB. These results provide useful reference values for future studies of maternal - fetal disease transmission, vaccine and drug evaluation in non-human primate pregnancy, as well as fetal programming and immune modulation, gene therapy and the use of UCB as a source of stem cells for research and transplantation. Importantly, our results suggest that maternal gravidity may be an important variable to consider.
Mederico, Maracelly; Paoli, Mariela; Zerpa, Yajaira; Briceño, Yajaira; Gómez-Pérez, Roald; Martínez, José Luis; Camacho, Nolis; Cichetti, Rosanna; Molina, Zarela; Mora, Yolanda; Valeri, Lenin
2013-05-01
To collect regional reference values of waist circumference (WC), and waist/hip ratio (WHR) in children and adolescents from Merida, Venezuela, and to compare them to international references. A total of 919 students aged 9-17 years from public and private educational establishments were assessed. Weight, height, WC, and WHR were measured. Outliers (± 3 SD Z-Score) were excluded from the data collected. Percentile distribution of the tested variables was done by age and sex. Fifty-one percent of subjects were female, and 52.7% were from public institutions. WC (p=0.001) and WHR (p=0.0001) were statistically higher in boys. With advancing age, WC increased in both sexes, while WHR showed the opposite behavior (p=0.0001 for both). The 90th percentile (pc) for WC ranged from 69.7 and 83.6 cm in girls and from 69.2 and 86.7 cm in boys. The 90th pc values of WHR ranged from 0.79 and 0.91 in girls and from 0.86 and 0.93 in boys. Overall, our WC and WHR values were lower than North American values and similar to those of some Latin American references. Percentile reference charts for WC and WHR specific for age and sex, obtained from a representative sample of children and adolescents from Mérida, Venezuela, are provided. They may be used regionally, both for individual assessment and to implement prevention policies. Copyright © 2012 SEEN. Published by Elsevier Espana. All rights reserved.
Strategies to Improve the Accuracy of Mars-GRAM Sensitivity Studies at Large Optical Depths
NASA Technical Reports Server (NTRS)
Justh, Hilary L.; Justus, Carl G.; Badger, Andrew M.
2010-01-01
The poster provides an overview of techniques to improve the Mars Global Reference Atmospheric Model (Mars-GRAM) sensitivity. It has been discovered during the Mars Science Laboratory (MSL) site selection process that the Mars Global Reference Atmospheric Model (Mars-GRAM) when used for sensitivity studies for TES MapYear = 0 and large optical depth values such as tau = 3 is less than realistic. A preliminary fix has been made to Mars-GRAM by adding a density factor value that was determined for tau = 0.3, 1 and 3.
Fan, Bo; Ng, Bennett K.; Shepherd, John A.
2017-01-01
Body Mass Index has traditionally been used as a measure of health, but Fat Mass Index (FMI) and Lean Mass Index (LMI) have been shown to be more predictive of mortality and health risk. Total body FMI and LMI reference curves have particularly been useful in quantifying sarcopenia and sarcopenic obesity. Research has shown regional composition has significant associations to health outcomes. We derived FMI and LMI reference curves of the regions of the body (leg, arm, and trunk) for 15,908 individuals in the 1999–2004 National Health and Nutrition Examination Survey data for each sex and ethnicity using the Lambda-Mu-Sigma (LMS) method and developed software to visualize this regional composition. These reference curves displayed differentiation between males and females during puberty and sharper limb LMI declines during late adulthood for males. For adults ages 30–50, females had 39%, 83%, and 47% larger arm, leg, and trunk FMI values than males, respectively. Males had 49%, 20%, and 15% higher regional LMI values than females for the arms, legs, and trunk respectively. The leg FMI and LMI of black females were 14% and 15% higher respectively than those of Hispanic and white females. White and Hispanic males had 37% higher trunk FMI values than black males. Hispanic females had 20% higher trunk FMI than white and black females. These data underscore the importance of accounting for sex and ethnicity in studies of regional composition. This study is the first to produce regional LMI and FMI reference tables and curves from the NHANES dataset. These reference curves provide a framework useful in studies and research involving sarcopenia, obesity, sarcopenic obesity, and other studies of compositional phenotypes. Further, the software tool we provide for visualizing regional composition will prove useful in monitoring progress in physical therapy, diets, or other attempts to attain healthier compositions. PMID:28346492
Ulmer, Candice Z; Ragland, Jared M; Koelmel, Jeremy P; Heckert, Alan; Jones, Christina M; Garrett, Timothy J; Yost, Richard A; Bowden, John A
2017-12-19
As advances in analytical separation techniques, mass spectrometry instrumentation, and data processing platforms continue to spur growth in the lipidomics field, more structurally unique lipid species are detected and annotated. The lipidomics community is in need of benchmark reference values to assess the validity of various lipidomics workflows in providing accurate quantitative measurements across the diverse lipidome. LipidQC addresses the harmonization challenge in lipid quantitation by providing a semiautomated process, independent of analytical platform, for visual comparison of experimental results of National Institute of Standards and Technology Standard Reference Material (SRM) 1950, "Metabolites in Frozen Human Plasma", against benchmark consensus mean concentrations derived from the NIST Lipidomics Interlaboratory Comparison Exercise.
Radionuclide calorimeter system
Donohoue, Thomas P.; Oertel, Christopher P.; Tyree, William H.; Valdez, Joe L.
1991-11-26
A circuit for measuring temperature differentials in a calorimeter is disclosed. The temperature differential between the reference element and sample element containing a radioactive material is measured via a wheatstone bridge arrangement of thermistors. The bridge is driven with an alternating current on a pulsed basis to maintain the thermal floor of the calorimeter at a low reference value. A lock-in amplifier connected to the bridge phase locks a signal from the bridge to the input pulsed AC signal to provide a DC voltage. The DC voltage is sampled over time and provided to a digital computer. The digital computer, using curve fitting algorithms, will derive a function for the sample data. From the function, an equilibrium value for the temperature may be calculated.
Radionuclide calorimeter system
Donohoue, T.P.; Oertel, C.P.; Tyree, W.H.; Valdez, J.L.
1991-11-26
A circuit for measuring temperature differentials in a calorimeter is disclosed. The temperature differential between the reference element and sample element containing a radioactive material is measured via a Wheatstone bridge arrangement of thermistors. The bridge is driven with an alternating current on a pulsed basis to maintain the thermal floor of the calorimeter at a low reference value. A lock-in amplifier connected to the bridge phase locks a signal from the bridge to the input pulsed AC signal to provide a DC voltage. The DC voltage is sampled over time and provided to a digital computer. The digital computer, using curve fitting algorithms, will derive a function for the sample data. From the function, an equilibrium value for the temperature may be calculated. 7 figures.
75 FR 29435 - Diquat Dibromide; Pesticide Tolerances
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-26
... requests are provided in 40 CFR 178.25(b). In addition to filing an objection or hearing request with the... basis for derivation of reference values for risk assessment. PODs are developed based on a careful... addition, the Agency must provide for periodic evaluation of any estimates used. To provide for the...
NASA Astrophysics Data System (ADS)
Wziontek, H.; Palinkas, V.; Falk, R.; Vaľko, M.
2016-12-01
Since decades, absolute gravimeters are compared on a regular basis on an international level, starting at the International Bureau for Weights and Measures (BIPM) in 1981. Usually, these comparisons are based on constant reference values deduced from all accepted measurements acquired during the comparison period. Temporal changes between comparison epochs are usually not considered. Resolution No. 2, adopted by IAG during the IUGG General Assembly in Prague 2015, initiates the establishment of a Global Absolute Gravity Reference System based on key comparisons of absolute gravimeters (AG) under the International Committee for Weights and Measures (CIPM) in order to establish a common level in the microGal range. A stable and unique reference frame can only be achieved, if different AG are taking part in different kind of comparisons. Systematic deviations between the respective comparison reference values can be detected, if the AG can be considered stable over time. The continuous operation of superconducting gravimeters (SG) on selected stations further supports the temporal link of comparison reference values by establishing a reference function over time. By a homogenous reprocessing of different comparison epochs and including AG and SG time series at selected stations, links between several comparisons will be established and temporal comparison reference functions will be derived. By this, comparisons on a regional level can be traced to back to the level of key comparisons, providing a reference for other absolute gravimeters. It will be proved and discussed, how such a concept can be used to support the future absolute gravity reference system.
A Field Guide to Kentucky Lakes and Wetlands.
ERIC Educational Resources Information Center
Kentucky State Div. of Water, Frankfort. Kentucky Natural Resources and Environmental Protection Cabinet.
Lakes and wetlands make up that part of Kentucky's water bodies commonly referred to as standing waters. These waters serve many purposes for the people of the state and are necessary and valued elements of its natural resources. This field guide was designed to provide useful background information and reference material for the study of these…
Fostering Creativity with Wisdom
ERIC Educational Resources Information Center
Craft, Anna
2006-01-01
Over the past five years, creativity has become a focus of attention for policy-makers in education. However, the increased interest in creativity has occurred as if without reference to any value framework. This article suggests that in fact an invisible underpinning value framework has been provided by western individualism, in turn both…
Learning about Global Interdependence: An Area-Value Mapping Exercise.
ERIC Educational Resources Information Center
Crooker, Richard A.
1990-01-01
Presents a lesson for secondary school students that uses an area value map to increase student understanding about the geography of international drug production and consumption. Provides a list of necessary classroom materials, suggested background readings for students, procedures to be followed, and a bibliography of references. (DB)
26 CFR 1.817A-1 - Certain modified guaranteed contracts.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., other equity instruments, or equity-based derivatives. (5) Current market rate for non-equity-indexed... to time with reference to market values for annual statement purposes. Further, an MGC must provide... policyholder upon surrender is usually increased or decreased by a market value adjustment, which is determined...
Chlorine Dioxide Disinfection in the Use of Individual Water Purification Devices
2006-03-01
CTs ranging from 1.7-17.6 mg-min/L necessary for 2-log Giardia muris cyst inactivation (reference 23). The SWTR provides the following CT values...reference 3). A comparison of CTs required for a 2-log inactivation for E. Coli bacteria, Poliovirus 1, and Giardia cysts showed Giardia cysts were 2-5...Cryptosporidium oocysts are the most resistant, being 8-16 times more resistant than Giardia cysts (reference 5). Chlorine dioxide’s general disinfection
Sub-Audible Speech Recognition Based upon Electromyographic Signals
NASA Technical Reports Server (NTRS)
Jorgensen, Charles C. (Inventor); Agabon, Shane T. (Inventor); Lee, Diana D. (Inventor)
2012-01-01
Method and system for processing and identifying a sub-audible signal formed by a source of sub-audible sounds. Sequences of samples of sub-audible sound patterns ("SASPs") for known words/phrases in a selected database are received for overlapping time intervals, and Signal Processing Transforms ("SPTs") are formed for each sample, as part of a matrix of entry values. The matrix is decomposed into contiguous, non-overlapping two-dimensional cells of entries, and neural net analysis is applied to estimate reference sets of weight coefficients that provide sums with optimal matches to reference sets of values. The reference sets of weight coefficients are used to determine a correspondence between a new (unknown) word/phrase and a word/phrase in the database.
Perich, C; Ricós, C; Alvarez, V; Biosca, C; Boned, B; Cava, F; Doménech, M V; Fernández-Calle, P; Fernández-Fernández, P; García-Lario, J V; Minchinela, J; Simón, M; Jansen, R
2014-05-15
Current external quality assurance schemes have been classified into six categories, according to their ability to verify the degree of standardization of the participating measurement procedures. SKML (Netherlands) is a Category 1 EQA scheme (commutable EQA materials with values assigned by reference methods), whereas SEQC (Spain) is a Category 5 scheme (replicate analyses of non-commutable materials with no values assigned by reference methods). The results obtained by a group of Spanish laboratories participating in a pilot study organized by SKML are examined, with the aim of pointing out the improvements over our current scheme that a Category 1 program could provide. Imprecision and bias are calculated for each analyte and laboratory, and compared with quality specifications derived from biological variation. Of the 26 analytes studied, 9 had results comparable with those from reference methods, and 10 analytes did not have comparable results. The remaining 7 analytes measured did not have available reference method values, and in these cases, comparison with the peer group showed comparable results. The reasons for disagreement in the second group can be summarized as: use of non-standard methods (IFCC without exogenous pyridoxal phosphate for AST and ALT, Jaffé kinetic at low-normal creatinine concentrations and with eGFR); non-commutability of the reference material used to assign values to the routine calibrator (calcium, magnesium and sodium); use of reference materials without established commutability instead of reference methods for AST and GGT, and lack of a systematic effort by manufacturers to harmonize results. Results obtained in this work demonstrate the important role of external quality assurance programs using commutable materials with values assigned by reference methods to correctly monitor the standardization of laboratory tests with consequent minimization of risk to patients. Copyright © 2013 Elsevier B.V. All rights reserved.
Jairam, Pushpa M; de Jong, Pim A; Mali, Willem P Th M; Gondrie, Martijn J A; Jacobs, Peter C A; van der Graaf, Yolanda
2014-08-01
To establish age and gender specific reference values for incidental coronary artery and thoracic aorta calcification scores on routine diagnostic CT scans. These reference values can aid in structured reporting and interpretation of readily available imaging data by chest CT readers in routine practice. A random sample of 1572 (57% male, median age 61 years) was taken from a study population of 12,063 subjects who underwent diagnostic chest CT for non-cardiovascular indications between January 2002 and December 2005. Coronary artery and thoracic aorta calcifications were graded using a validated ordinal score. The 25th, 50th and 75th percentile cut points were calculated for the coronary artery and thoracic aorta calcification scores within each age/gender stratum. The 75th percentile cut points for coronary artery calcification scores were higher for men than for women across all age groups, with the exception of the lowest age group. The 75th percentile cut points for thoracic aorta calcifications scores were comparable for both genders across all age groups. Based on the obtained age and gender reference values a calculation tool is provided, that allows one to enter an individual's age, gender and calcification scores to obtain the corresponding estimated percentiles. The calculation tool as provided in this study can be used in daily practice by CT readers to examine whether a subject has high calcifications scores relative to others with the same age and gender. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Value assignment and uncertainty evaluation for single-element reference solutions
NASA Astrophysics Data System (ADS)
Possolo, Antonio; Bodnar, Olha; Butler, Therese A.; Molloy, John L.; Winchester, Michael R.
2018-06-01
A Bayesian statistical procedure is proposed for value assignment and uncertainty evaluation for the mass fraction of the elemental analytes in single-element solutions distributed as NIST standard reference materials. The principal novelty that we describe is the use of information about relative differences observed historically between the measured values obtained via gravimetry and via high-performance inductively coupled plasma optical emission spectrometry, to quantify the uncertainty component attributable to between-method differences. This information is encapsulated in a prior probability distribution for the between-method uncertainty component, and it is then used, together with the information provided by current measurement data, to produce a probability distribution for the value of the measurand from which an estimate and evaluation of uncertainty are extracted using established statistical procedures.
Sharpless, K E; Gill, L M
2000-01-01
A number of food-matrix reference materials (RMs) are available from the National Institute of Standards and Technology (NIST) and from Agriculture Canada through NIST. Most of these materials were originally value-assigned for their elemental composition (major, minor, and trace elements), but no additional nutritional information was provided. Two of the materials were certified for selected organic constituents. Ten of these materials (Standard Reference Material [SRM] 1,563 Cholesterol and Fat-Soluble Vitamins in Coconut Oil [Natural and Fortified], SRM 1,566b Oyster Tissue, SRM 1,570a Spinach Leaves, SRM 1,974a Organics in Mussel Tissue (Mytilus edulis), RM 8,415 Whole Egg Powder, RM 8,418 Wheat Gluten, RM 8,432 Corn Starch, RM 8,433 Corn Bran, RM 8,435 Whole Milk Powder, and RM 8,436 Durum Wheat Flour) were recently distributed by NIST to 4 laboratories with expertise in food analysis for the measurement of proximates (solids, fat, protein, etc.), calories, and total dietary fiber, as appropriate. SRM 1846 Infant Formula was distributed as a quality control sample for the proximates and for analysis for individual fatty acids. Two of the materials (Whole Egg Powder and Whole Milk Powder) were distributed in an earlier interlaboratory comparison exercise in which they were analyzed for several vitamins. Value assignment of analyte concentrations in these 11 SRMs and RMs, based on analyses by the collaborating laboratories, is described in this paper. These materials are intended primarily for validation of analytical methods for the measurement of nutrients in foods of similar composition (based on AOAC INTERNATIONAL's fat-protein-carbohydrate triangle). They may also be used as "primary control materials" in the value assignment of in-house control materials of similar composition. The addition of proximate information for 10 existing reference materials means that RMs are now available from NIST with assigned values for proximates in 6 of the 9 sectors of the AOAC triangle. Five of these materials have values assigned for total dietary fiber-the first such information provided for materials available from NIST.
Research on Ratio of Dosage of Drugs in Traditional Chinese Prescriptions by Data Mining.
Yu, Xing-Wen; Gong, Qing-Yue; Hu, Kong-Fa; Mao, Wen-Jing; Zhang, Wei-Ming
2017-01-01
Maximizing the effectiveness of prescriptions and minimizing adverse effects of drugs is a key component of the health care of patients. In the practice of traditional Chinese medicine (TCM), it is important to provide clinicians a reference for dosing of prescribed drugs. The traditional Cheng-Church biclustering algorithm (CC) is optimized and the data of TCM prescription dose is analyzed by using the optimization algorithm. Based on an analysis of 212 prescriptions related to TCM treatment of kidney diseases, the study generated 87 prescription dose quantum matrices and each sub-matrix represents the referential value of the doses of drugs in different recipes. The optimized CC algorithm can effectively eliminate the interference of zero in the original dose matrix of TCM prescriptions and avoid zero appearing in output sub-matrix. This results in the ability to effectively analyze the reference value of drugs in different prescriptions related to kidney diseases, so as to provide valuable reference for clinicians to use drugs rationally.
Fine-tuning satellite-based rainfall estimates
NASA Astrophysics Data System (ADS)
Harsa, Hastuadi; Buono, Agus; Hidayat, Rahmat; Achyar, Jaumil; Noviati, Sri; Kurniawan, Roni; Praja, Alfan S.
2018-05-01
Rainfall datasets are available from various sources, including satellite estimates and ground observation. The locations of ground observation scatter sparsely. Therefore, the use of satellite estimates is advantageous, because satellite estimates can provide data on places where the ground observations do not present. However, in general, the satellite estimates data contain bias, since they are product of algorithms that transform the sensors response into rainfall values. Another cause may come from the number of ground observations used by the algorithms as the reference in determining the rainfall values. This paper describe the application of bias correction method to modify the satellite-based dataset by adding a number of ground observation locations that have not been used before by the algorithm. The bias correction was performed by utilizing Quantile Mapping procedure between ground observation data and satellite estimates data. Since Quantile Mapping required mean and standard deviation of both the reference and the being-corrected data, thus the Inverse Distance Weighting scheme was applied beforehand to the mean and standard deviation of the observation data in order to provide a spatial composition of them, which were originally scattered. Therefore, it was possible to provide a reference data point at the same location with that of the satellite estimates. The results show that the new dataset have statistically better representation of the rainfall values recorded by the ground observation than the previous dataset.
Quantity quotient reporting. A proposal for a standardized presentation of laboratory results.
Haeckel, Rainer; Wosniok, Werner
2009-01-01
Laboratory results are reported in different units (despite international recommendations for SI units) together with different reference limits, of which several exist for many quantities. It is proposed to adopt the concept of the intelligence quotient and to report quantitative results as a quantity quotient (QQ) in laboratory medicine. This quotient is essentially the difference (measured result minus mean or mode value of the reference interval) divided by the observed biological variation CV(o). Thus, all quantities are reported in the same unit system with the same reference limits (for convenience shifted to e.g., 80-120). The critical difference can also be included in this standardization concept. In this way the information of reference intervals and the original result are integrated into one combined value, which has the same format for all quantities suited for quotient reporting (QR). The proposal of QR does not interfere with neither the current concepts of traceability, SI units or method standardization. This proposal represents a further step towards harmonization of reporting. It provides simple values which can be interpreted easily by physicians and their patients.
SU-E-P-10: Establishment of Local Diagnostic Reference Levels of Routine Exam in Computed Tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yeh, M; Wang, Y; Weng, H
Introduction National diagnostic reference levels (NDRLs) can be used as a reference dose of radiological examination can provide radiation dose as the basis of patient dose optimization. Local diagnostic reference levels (LDRLs) by periodically view and check doses, more efficiency to improve the way of examination. Therefore, the important first step is establishing a diagnostic reference level. Computed Tomography in Taiwan had been built up the radiation dose limit value,in addition, many studies report shows that CT scan contributed most of the radiation dose in different medical. Therefore, this study was mainly to let everyone understand DRL’s international status. Formore » computed tomography in our hospital to establish diagnostic reference levels. Methods and Materials: There are two clinical CT scanners (a Toshiba Aquilion and a Siemens Sensation) were performed in this study. For CT examinations the basic recommended dosimetric quantity is the Computed Tomography Dose Index (CTDI). Each exam each different body part, we collect 10 patients at least. Carried out the routine examinations, and all exposure parameters have been collected and the corresponding CTDIv and DLP values have been determined. Results: The majority of patients (75%) were between 60–70 Kg of body weight. There are 25 examinations in this study. Table 1 shows the LDRL of each CT routine examination. Conclusions: Therefore, this study would like to let everyone know DRL’s international status, but also establishment of computed tomography of the local reference levels for our hospital, and providing radiation reference, as a basis for optimizing patient dose.« less
Assessing bioequivalence of generic antiepilepsy drugs.
Krauss, Gregory L; Caffo, Brian; Chang, Yi-Ting; Hendrix, Craig W; Chuang, Kelly
2011-08-01
Patients with epilepsy are often concerned that switching between brand-name and generic formulations of antiepilepsy drugs (AEDs) may cause clinically significant changes in plasma drug concentrations. We assessed bioequivalence (BE) studies for approved generic AEDs to evaluate US Food and Drug Administration claims that: (1) generic AEDs are accurate copies of reference formulations; (2) delivery of reference formulations may be as variable as generic AEDs and so provide no increased benefit; and (3) switches between generic AED formulations are safe and effective. We determined differences in 90% confidence interval limits for total drug exposure (AUC(0-t) ) and peak concentration (Cmax) ratios of generic and reference formulations during fasting and fed BE studies. We simulated BE between generic formulations after adjusting for reference values. AUC(0-t) values of approved reference and generic formulations differed by <15% in 99% of BE studies; Cmax differed by <15% in 89% of studies. Food affected variability of Cmax but not AUC(0-t) . Intersubject variability in Cmax and AUC(0-t) was small and similar for reference and generic products. In simulated switches between 595 pairs of generic AED formulations, estimated AUC(0-t) differed by >15% for 17% of pairs; estimated Cmax differed by >15% for 39%. AEDs with low bioavailability and solubility (eg, oxcarbazepine) had the greatest variability in BE. Most generic AED products provide total drug delivery (AUC) similar to reference products; differences in peak concentrations between formulations are more common. Switches between generic AED products may cause greater changes in plasma drug concentrations than generic substitutions of reference products. Copyright © 2011 American Neurological Association.
Designing robots for care: care centered value-sensitive design.
van Wynsberghe, Aimee
2013-06-01
The prospective robots in healthcare intended to be included within the conclave of the nurse-patient relationship--what I refer to as care robots--require rigorous ethical reflection to ensure their design and introduction do not impede the promotion of values and the dignity of patients at such a vulnerable and sensitive time in their lives. The ethical evaluation of care robots requires insight into the values at stake in the healthcare tradition. What's more, given the stage of their development and lack of standards provided by the International Organization for Standardization to guide their development, ethics ought to be included into the design process of such robots. The manner in which this may be accomplished, as presented here, uses the blueprint of the Value-sensitive design approach as a means for creating a framework tailored to care contexts. Using care values as the foundational values to be integrated into a technology and using the elements in care, from the care ethics perspective, as the normative criteria, the resulting approach may be referred to as care centered value-sensitive design. The framework proposed here allows for the ethical evaluation of care robots both retrospectively and prospectively. By evaluating care robots in this way, we may ultimately ask what kind of care we, as a society, want to provide in the future.
[Reference values of carbohydrates for the Venezuelan population].
Marisela, Granito; Suhey, Pérez; Yolmar, Valero; Colina, Jhoana
2013-12-01
An update of the nutritional recommendations for carbohydrate intake to the Venezuelan population was performed. For this work the concepts, data and methodology followed by other countrie's or groups of countries to obtain and document their own reference, in order to provide basic information to facilitate the establishment of reference values can be revised to better adapt to the Venezuelan population. The data correspond to healthy populations and taken as reference the recommendations of the Food and Nutrition Board of the U.S., the Committees of Experts on Energy and Protein FAO/WHO, among others. As a result of the literature review, the historical caloric formula of population and dietary patterns of Venezuela was propose the consumption of total carbohydrate intake between 50 and 60% of total caloric intake and simple sugars do not exceed 10% of intake. It is suggested to increase the consumption of vegetables, whole grains, legumes, vegetables and whole tropical fruits.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-16
... securities product (``UTP Derivative Security'') that derives its value from one or more currencies or..., proposed EDGA Rule 14.1(c)(5)(A) provides that a Restricted Market Maker in a UTP Derivative Security on... Reference Asset of that UTP Derivative Security, or any derivative instrument based on a Reference Asset of...
Dong, Lianhua; Meng, Ying; Wang, Jing; Liu, Yingying
2014-02-01
DNA reference materials of certified value have a critical function in many analytical processes of DNA measurement. Quantification of amoA genes in ammonia oxidizing bacteria (AOB) and archaea (AOA), and of nirS and nosZ genes in the denitrifiers is very important for determining their distribution and abundance in the natural environment. A plasmid reference material containing nirS, nosZ, amoA-AOB, and amoA-AOA is developed to provide a DNA standard with copy number concentration for ensuring comparability and reliability of quantification of these genes. Droplet digital PCR (ddPCR) was evaluated for characterization of the plasmid reference material. The result revealed that restriction endonuclease digestion of plasmids can improve amplification efficiency and minimize the measurement bias of ddPCR. Compared with the conformation of the plasmid, the size of the DNA fragment containing the target sequence and the location of the restriction site relative to the target sequence are not significant factors affecting plasmid quantification by ddPCR. Liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) was used to provide independent data for quantifying the plasmid reference material. The copy number concentration of the digested plasmid determined by ddPCR agreed well with that determined by LC-IDMS, improving both the accuracy and reliability of the plasmid reference material. The reference value, with its expanded uncertainty (k = 2), of the plasmid reference material was determined to be (5.19 ± 0.41) × 10(9) copies μL(-1) by averaging the results of two independent measurements. Consideration of the factors revealed in this study can improve the reliability and accuracy of ddPCR; thus, this method has the potential to accurately quantify DNA reference materials.
Nocturnal oxygen saturation profiles of healthy term infants.
Terrill, Philip Ian; Dakin, Carolyn; Hughes, Ian; Yuill, Maggie; Parsley, Chloe
2015-01-01
Pulse oximetry is used extensively in hospital and home settings to measure arterial oxygen saturation (SpO2). Interpretation of the trend and range of SpO2 values observed in infants is currently limited by a lack of reference ranges using current devices, and may be augmented by development of cumulative frequency (CF) reference-curves. This study aims to provide reference oxygen saturation values from a prospective longitudinal cohort of healthy infants. Prospective longitudinal cohort study. Sleep-laboratory. 34 healthy term infants were enrolled, and studied at 2 weeks, 3, 6, 12 and 24 months of age (N=30, 25, 27, 26, 20, respectively). Full overnight polysomnography, including 2 s averaging pulse oximetry (Masimo Radical). Summary SpO2 statistics (mean, median, 5th and 10th percentiles) and SpO2 CF plots were calculated for each recording. CF reference-curves were then generated for each study age. Analyses were repeated with sleep-state stratifications and inclusion of manual artefact removal. Median nocturnal SpO2 values ranged between 98% and 99% over the first 2 years of life and the CF reference-curves shift right by 1% between 2 weeks and 3 months. CF reference-curves did not change with manual artefact removal during sleep and did not vary between rapid eye movement (REM) and non-REM sleep. Manual artefact removal did significantly change summary statistics and CF reference-curves during wake. SpO2 CF curves provide an intuitive visual tool for evaluating whether an individual's nocturnal SpO2 distribution falls within the range of healthy age-matched infants, thereby complementing summary statistics in the interpretation of extended oximetry recordings in infants. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Fiber optic inclination detector system having a weighted sphere with reference points
Cwalinski, Jeffrey P.
1995-01-01
A fiber optic inclination detector system for determining the angular displacement of an object from a reference surface includes a simple mechanical transducer which requires a minimum number of parts and no electrical components. The system employs a single light beam which is split into two light beams and provided to the transducer. Each light beam is amplitude modulated upon reflecting off the transducer to detect inclination. The power values associated with each of the reflected light beams are converted by a pair of photodetectors into voltage signals, and a microprocessor manipulates the voltage signals to provide a measure of the angular displacement between the object and the reference surface.
Connecting Swath Satellite Data With Imagery in Mapping Applications
NASA Astrophysics Data System (ADS)
Thompson, C. K.; Hall, J. R.; Penteado, P. F.; Roberts, J. T.; Zhou, A. Y.
2016-12-01
Visualizations of gridded science data products (referred to as Level 3 or Level 4) typically provide a straightforward correlation between image pixels and the source science data. This direct relationship allows users to make initial inferences based on imagery values, facilitating additional operations on the underlying data values, such as data subsetting and analysis. However, that same pixel-to-data relationship for ungridded science data products (referred to as Level 2) is significantly more challenging. These products, also referred to as "swath products", are in orbital "instrument space" and raster visualization pixels do not directly correlate to science data values. Interpolation algorithms are often employed during the gridding or projection of a science dataset prior to image generation, introducing intermediary values that separate the image from the source data values. NASA's Global Imagery Browse Services (GIBS) is researching techniques for efficiently serving "image-ready" data allowing client-side dynamic visualization and analysis capabilities. This presentation will cover some GIBS prototyping work designed to maintain connectivity between Level 2 swath data and its corresponding raster visualizations. Specifically, we discuss the DAta-to-Image-SYstem (DAISY), an indexing approach for Level 2 swath data, and the mechanisms whereby a client may dynamically visualize the data in raster form.
The dimensional salience solution to the expectancy-value muddle: an extension.
Newton, Joshua D; Newton, Fiona J; Ewing, Michael T
2014-01-01
The theory of reasoned action (TRA) specifies a set of expectancy-value, belief-based frameworks that underpin attitude (behavioural beliefs × outcome evaluations) and subjective norm (normative beliefs × motivation to comply). Unfortunately, the most common method for analysing these frameworks generates statistically uninterpretable findings, resulting in what has been termed the 'expectancy-value muddle'. Recently, however, a dimensional salience approach was found to resolve this muddle for the belief-based framework underpinning attitude. An online survey of 262 participants was therefore conducted to determine whether the dimensional salience approach could also be applied to the belief-based framework underpinning subjective norm. Results revealed that motivations to comply were greater for salient, as opposed to non-salient, social referents. The belief-based framework underpinning subjective norm was therefore represented by evaluating normative belief ratings for salient social referents. This modified framework was found to predict subjective norm, although predictions were greater when participants were forced to select five salient social referents rather than being free to select any number of social referents. These findings validate the use of the dimensional salience approach for examining the belief-based frameworks underpinning subjective norm. As such, this approach provides a complete solution to addressing the expectancy-value muddle in the TRA.
Lu, Xianbo; Chen, Jiping; Wang, Shuqiu; Zou, Lili; Tian, Yuzeng; Ni, Yuwen; Su, Fan
2012-09-01
A method for the preparation and certification of the reference material of organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) in mussel tissue is described. The mussel tissue from Dalian Bay was frozen-dried, comminuted, sieved, homogenized, packaged, and sterilized by 60Co radiation sterilization in turn. The certified values for 18 OCPs and 16 PCBs were determined by high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) using isotope dilution and internal standard quantitation techniques. The certified values were validated and given based on seven accredited laboratories, and these values are traceable to the SI (international system of units) through gravimetrically prepared standards of established purity and measurement intercomparisons. The certified values of PCBs and OCPs in mussel span 4 orders of magnitude with a relative uncertainty of about 10%. This material is a natural biological material with confirmed good homogeneity and stability, and it was approved as the grade "primary reference material" (GBW10069) in June 2012 in China. This reference material provided necessary quality control products for our country to implement the Stockholm Treaty on the monitoring of persistent organic pollutants (POPs). The material is intended to be used for the method validation and quality control in the determination of OCPs and PCBs in biota samples.
Herbert, Annie; Cruickshank, John Kennedy; Laurent, Stéphane; Boutouyrie, Pierre
2014-11-21
Estimated central systolic blood pressure (cSBP) and amplification (Brachial SBP-cSBP) are non-invasive measures potentially prognostic of cardiovascular (CV) disease. No worldwide, multiple-device reference values are available. We aimed to establish reference values for a worldwide general population standardizing between the different available methods of measurement. How these values were significantly altered by cardiovascular risk factors (CVRFs) was then investigated. Existing data from population surveys and clinical trials were combined, whether published or not. Reference values of cSBP and amplification were calculated as percentiles for 'Normal' (no CVRFs) and 'Reference' (any CVRFs) populations. We included 45,436 subjects out of 82,930 that were gathered from 77 studies of 53 centres. Included subjects were apparently healthy, not treated for hypertension or dyslipidaemia, and free from overt CV disease and diabetes. Values of cSBP and amplification were stratified by brachial blood pressure categories and age decade in turn, both being stratified by sex. Amplification decreased with age and more so in males than in females. Sex was the most powerful factor associated with amplification with 6.6 mmHg (5.8-7.4) higher amplification in males than in females. Amplification was marginally but significantly influenced by CVRFs, with smoking and dyslipidaemia decreasing amplification, but increased with increasing levels of blood glucose. Typical values of cSBP and amplification in a healthy population and a population free of traditional CVRFs are now available according to age, sex, and brachial BP, providing values included from different devices with a wide geographical representation. Amplification is significantly influenced by CVRFs, but differently in men and women. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.
Miller, Donald L.; Kwon, Deukwoo; Bonavia, Grant H.
2009-01-01
Purpose: To propose initial values for patient reference levels for fluoroscopically guided procedures in the United States. Materials and Methods: This secondary analysis of data from the Radiation Doses in Interventional Radiology Procedures (RAD-IR) study was conducted under a protocol approved by the institutional review board and was HIPAA compliant. Dose distributions (percentiles) were calculated for each type of procedure in the RAD-IR study where there were data from at least 30 cases. Confidence intervals for the dose distributions were determined by using bootstrap resampling. Weight banding and size correction methods for normalizing dose to patient body habitus were tested. Results: The different methods for normalizing patient radiation dose according to patient weight gave results that were not significantly different (P > .05). The 75th percentile patient radiation doses normalized with weight banding were not significantly different from those that were uncorrected for body habitus. Proposed initial reference levels for various interventional procedures are provided for reference air kerma, kerma-area product, fluoroscopy time, and number of images. Conclusion: Sufficient data exist to permit an initial proposal of values for reference levels for interventional radiologic procedures in the United States. For ease of use, reference levels without correction for body habitus are recommended. A national registry of radiation-dose data for interventional radiologic procedures is a necessary next step to refine these reference levels. © RSNA, 2009 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.2533090354/-/DC1 PMID:19789226
De Smedt, Delphine; Clays, Els; Höfer, Stefan; Oldridge, Neil; Kotseva, Kornelia; Maggioni, Aldo Pietro; Pogosova, Nana; Dolzhenko, Maryna; De Bacquer, Dirk
2016-07-01
HeartQoL is a recently developed core health-related quality of life instrument for patients with coronary heart disease. The current study aims to investigate its association with patients' coronary risk profile and to provide reference values for patients with coronary heart disease across Europe. Analyses are based on the EUROASPIRE IV (EUROpean Action on Secondary and Primary prevention through Intervention to Reduce Events) cross-sectional survey. Patients with a diagnosis of coronary heart disease were examined and interviewed six months to three years after their coronary event. The HeartQoL questionnaire was completed by 7261 coronary heart disease patients. Reference values were calculated and the association with the coronary risk profile was assessed. Significantly worse outcomes were observed in higher-risk patient groups. Both metabolic and behavioural risk factors were associated with worse HeartQoL outcomes. Further, the HeartQoL scores decreased as the number of risk factors increased. The mean global reference values in males were 2.27 ± 0.65 (<60 years), 2.30 ± 0.61 (between 60 and 69 years) and 2.19 ± 0.64 (≥70 years). Likewise, in females, the respective global HeartQoL reference values were 2.02 ± 0.67, 2.01 ± 0.66 and 1.83 ± 0.70. The ceiling effect in males was 11.4%, 10.4% and 7.4% for the three age classes respectively, whereas in females the ceiling effect was 5.2%, 3.5% and 1.9%, respectively. HeartQoL scores were associated with patients' coronary risk profile. The reference values may help other researchers to interpret HeartQoL scores. Further research should focus on the minimal important difference needed to evaluate the effect of therapies and lifestyle changes. © The European Society of Cardiology 2016.
Code of Federal Regulations, 2010 CFR
2010-07-01
... sample period. Accordingly, if the value thus calculated is high enough to be an exceedance, such an... Provided by the Sampler Information to be provided Appendix L sectionreference Availability Anytime 1 End...
Cacau, Lucas de Assis Pereira; de Santana-Filho, Valter Joviniano; Maynard, Luana G; Gomes, Mansueto; Fernandes, Marcelo; Carvalho, Vitor Oliveira
2016-01-01
The aim of the study is to compare the available reference values and the six-minute walk test equations in healthy children/adolescents. Our systematic review was planned and performed in accordance with the PRISMA guidelines. We included all studies that established reference values for the six-minute walk test in healthy children/adolescents. To perform this review, a research was performed in PubMed, EMBASE (via SCOPUS) and Cochrane (LILACS), Bibliographic Index Spanish in Health Sciences, Organization Collection Pan-American Health Organization, Publications of the World Health Organization and Scientific Electronic Library Online (SciELO) via Virtual Health Library until June 2015 without language restriction. The initial research identified 276 abstracts. Twelve studies met the inclusion criteria and were fully reviewed and approved by both reviewers. None of the selected studies presented sample size calculation. Most of the studies recruited children and adolescents from school. Six studies reported the use of random samples. Most studies used a corridor of 30 meters. All studies followed the American Thoracic Society guidelines to perform the six-minute walk test. The walked distance ranged 159 meters among the studies. Of the 12 included studies, 7 (58%) reported descriptive data and 6 (50%) established reference equation for the walked distance in the six-minute walk test. The reference value for the six-minute walk test in children and adolescents ranged substantially from studies in different countries. A reference equation was not provided in all studies, but the ones available took into account well established variables in the context of exercise performance, such as height, heart rate, age and weight. Countries that did not established reference values for the six-minute walk test should be encouraged to do because it would help their clinicians and researchers have a more precise interpretation of the test.
Cacau, Lucas de Assis Pereira; de Santana-Filho, Valter Joviniano; Maynard, Luana G.; Gomes Neto, Mansueto; Fernandes, Marcelo; Carvalho, Vitor Oliveira
2016-01-01
Objective The aim of the study is to compare the available reference values and the six-minute walk test equations in healthy children/adolescents. Our systematic review was planned and performed in accordance with the PRISMA guidelines. We included all studies that established reference values for the six-minute walk test in healthy children/adolescents. Methods To perform this review, a research was performed in PubMed, EMBASE (via SCOPUS) and Cochrane (LILACS), Bibliographic Index Spanish in Health Sciences, Organization Collection Pan-American Health Organization, Publications of the World Health Organization and Scientific Electronic Library Online (SciELO) via Virtual Health Library until June 2015 without language restriction. Results The initial research identified 276 abstracts. Twelve studies met the inclusion criteria and were fully reviewed and approved by both reviewers. None of the selected studies presented sample size calculation. Most of the studies recruited children and adolescents from school. Six studies reported the use of random samples. Most studies used a corridor of 30 meters. All studies followed the American Thoracic Society guidelines to perform the six-minute walk test. The walked distance ranged 159 meters among the studies. Of the 12 included studies, 7 (58%) reported descriptive data and 6 (50%) established reference equation for the walked distance in the six-minute walk test. Conclusion The reference value for the six-minute walk test in children and adolescents ranged substantially from studies in different countries. A reference equation was not provided in all studies, but the ones available took into account well established variables in the context of exercise performance, such as height, heart rate, age and weight. Countries that did not established reference values for the six-minute walk test should be encouraged to do because it would help their clinicians and researchers have a more precise interpretation of the test. PMID:27982347
Zhang, Hui; Cowling, David W; Facer, Matthew
2017-12-01
Various health insurance benefit designs based on value-based purchasing have been promoted to steer patients to high-value providers, but little is known about the designs' relative effectiveness and underlying mechanisms. We compared the impact of two designs implemented by the California Public Employees' Retirement System on inpatient hospital total hip or knee replacement: a reference-based pricing design for preferred provider organizations (PPOs) and a centers-of-excellence design for health maintenance organizations (HMOs). Payment and utilization data for the procedures in the period 2008-13 were evaluated using pre-post and quasi-experimental designs at the system and health plan levels, adjusting for demographic characteristics, case-mix, and other confounders. We found that both designs prompted higher use of designated low-price high-quality facilities and reduced average replacement expenses per member at the plan and system levels. However, the designs used different routes: The reference-based pricing design reduced average replacement payments per case in PPOs by 26.7 percent in the first year, compared to HMOs, but did not lower PPO members' utilization rates. In contrast, the centers-of-excellence design lowered HMO members' utilization rates by 29.2 percent in the first year, compared to PPOs, but did not reduce HMO average replacement payments per case. The reference-based pricing design appears more suitable for reducing price variation, and the centers-of-excellence design for addressing variation in use.
NASA Astrophysics Data System (ADS)
Lee, William H. K.; Engdahl, E. Robert
2015-02-01
Moment magnitude (MW) determinations from the online GCMT Catalogue of seismic moment tensor solutions (GCMT Catalog, 2011) have provided the bulk of MW values in the ISC-GEM Global Instrumental Reference Earthquake Catalogue (1900-2009) for almost all moderate-to-large earthquakes occurring after 1975. This paper describes an effort to determine MW of large earthquakes that occurred prior to the start of the digital seismograph era, based on credible assessments of thousands of seismic moment (M0) values published in the scientific literature by hundreds of individual authors. MW computed from the published M0 values (for a time period more than twice that of the digital era) are preferable to proxy MW values, especially for earthquakes with MW greater than about 8.5, for which MS is known to be underestimated or "saturated". After examining 1,123 papers, we compile a database of seismic moments and related information for 1,003 earthquakes with published M0 values, of which 967 were included in the ISC-GEM Catalogue. The remaining 36 earthquakes were not included in the Catalogue due to difficulties in their relocation because of inadequate arrival time information. However, 5 of these earthquakes with bibliographic M0 (and thus MW) are included in the Catalogue's Appendix. A search for reliable seismic moments was not successful for earthquakes prior to 1904. For each of the 967 earthquakes a "preferred" seismic moment value (if there is more than one) was selected and its uncertainty was estimated according to the data and method used. We used the IASPEI formula (IASPEI, 2005) to compute direct moment magnitudes (MW[M0]) based on the seismic moments (M0), and assigned their errors based on the uncertainties of M0. From 1900 to 1979, there are 129 great or near great earthquakes (MW ⩾ 7.75) - the bibliographic search provided direct MW values for 86 of these events (or 67%), the GCMT Catalog provided direct MW values for 8 events (or 6%), and the remaining 35 (or 27%) earthquakes have empirically determined proxy MW estimates. An electronic supplementary file is included with this paper in order to provide our M0/MW catalogue of earthquakes (1904-1978) from the published literature, and a reference list of the 1,123 papers that we examined.
Anti-wear Mechanism Analysis of Nano-CaCO3 Additives
NASA Astrophysics Data System (ADS)
Xu, Zhen; Sun, Junfeng
2018-06-01
In this paper, the wear test was carried on with cylinder piston by the wear test device, receiving the results of the piston ring wear and abrasive characteristics by monitoring the wear process, the thesis analysis and put forward the nano-CaCO3 lubricating oil additive anti wear mechanism by the ferrography analysis technology, and provide the technical reference for the relevant measures to reduce wear and the friction, and provide reference value for further study on the related theories of reducing wear and reducing friction.
Pathophysiology of Stress in Wild and Managed-Care Bottlenose Dolphins (Tursiops truncatus)
2014-09-30
populations to establish reference ranges and assess variability across populations (Schwacke et al., 2008). Additionally , thyroid reference values were...stress evaluation using classic stress hormones were paired with biomarker expression using proteomics and metabolomics to provide additional stress...dolphins (27 from the Indian River Lagoon, FL and 22 from Charleston, SC). Additionally , 10 GA and 10 MMP dolphins were sampled multiple times during
Predictive value and efficiency of laboratory testing.
Galen, R S
1980-11-01
Literature on determining reference values and reference intervals on "normal" or "healthy" individuals is abundant. It is impossible, however, to evaluate a data set of reference values and select a suitable reference interval that will be meaningful for the practice of medicine. The reference interval, no matter how derived statistically, tells us nothing about disease. This is the main reason the concepts of "normal values" have failed us and why "reference values" will prove similarly disappointing. By studying these same constituents in a variety of disease states as well, it will be possible to select "referent values" that will make the test procedure meaningful for diagnostic purposes. In order to obtain meaningful referent values for predicting disease, it is necessary to study not only the "healthy" reference population, but patients with the disease in question, and patients who are free of the disease in question but who have other diseases. Studies of this type are not frequently found for laboratory tests that are in common use today.
Hoeboer, J J A A M; Ongena, G; Krijger-Hombergen, M; Stolk, E; Savelsbergh, G J P; de Vries, S I
2018-02-07
The aim of the presented study is to provide age- and gender-related normative values and MQ values for a motor skills test, the Athletic Skills Track, among 4- to 12-year-old children. Cross-sectional. In 2016, a total of 7977 Dutch children, 4036 boys (mean age 8.6 years, SD 2.1) and 3941 girls (mean age 8.6 years, SD 2.1), performed an age-related version of the Athletic Skills Track (AST). The AST is a track consisting of 5-7 fundamental movement skill tasks that should be completed as fast as possible. The children performed the test during a regular physical education (PE) lesson under the supervision of their own PE teacher. For each version of the AST (AST-1: n=917; AST-2: n=3947; AST-3: n=3213) age- and gender-related reference centiles were derived from the gathered data using the Lambda, Mu, Sigma (LMS) method. All children completed the AST within 60s (mean 29.6s, SD 7.7). An independent samples t-test showed that boys were significantly faster in completing the track than girls, except for the 4-year-old boys. Therefore, age- and gender-related reference centiles were derived. The reference curves demonstrate an almost linear decrease in time to complete AST-1 and AST-2 with increasing age. The present study provides age- and gender-related normative values and MQ values for the AST among 4- to 12-year-old Dutch children. With these normative values PE teachers can interpret children's performance on the AST. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Miller, Robert; Stalder, Tobias; Jarczok, Marc; Almeida, David M.; Badrick, Ellena; Bartels, Meike; Boomsma, Dorret I.; Coe, Christopher L.; Dekker, Marieke C. J.; Donzella, Bonny; Fischer, Joachim E.; Gunnar, Megan R.; Kumari, Meena; Lederbogen, Florian; Oldehinkel, Albertine J.; Power, Christine; Rosmalen, Judith G.; Ryff, Carol D.; Subramanian, S V; Tiemeier, Henning; Watamura, Sarah E.; Kirschbaum, Clemens
2016-01-01
Diurnal salivary cortisol profiles are valuable indicators of adrenocortical functioning in epidemiological research and clinical practice. However, normative reference values derived from a large number of participants and across a wide age range are still missing. To fill this gap, data were compiled from 15 independently conducted field studies with a total of 104,623 salivary cortisol samples obtained from 18,698 unselected individuals (mean age: 48.3 years, age range: 0.5 to 98.5 years, 39% females). Besides providing a descriptive analysis of the complete dataset, we also performed mixed-effects growth curve modeling of diurnal salivary cortisol (i.e., 1 to 16 hours after awakening). Cortisol decreased significantly across the day and was influenced by both, age and sex. Intriguingly, we also found a pronounced impact of sampling season with elevated diurnal cortisol in spring and decreased levels in autumn. However, the majority of variance was accounted for by between-participant and between-study variance components. Based on these analyses, reference ranges (LC/MS-MS calibrated) for cortisol concentrations in saliva were derived for different times across the day, with more specific reference ranges generated for males and females in different age categories. This integrative summary provides important reference values on salivary cortisol to aid basic scientists and clinicians in interpreting deviations from the normal diurnal cycle. PMID:27448524
Global Reference Atmosphere Model (GRAM)
NASA Technical Reports Server (NTRS)
Johnson, D. L.; Blocker, Rhonda; Justus, C. G.
1993-01-01
4D model provides atmospheric parameter values either automatically at positions along linear path or along any set of connected positions specified by user. Based on actual data, GRAM provides thermal wind shear for monthly mean winds, percent deviation from standard atmosphere, mean vertical wind, and perturbation data for each position.
Teaching Orienteering. Second Edition.
ERIC Educational Resources Information Center
McNeill, Carol; Cory-Wright, Jean; Renfrew, Tom
The educational value provided by orienteering's blend of navigational and physical skills has given it a permanent place in the primary and secondary school curriculum in the United Kingdom. This book is a reference to orienteering for teachers, leaders, and coaches. It provides a "how to" approach to introducing and developing the…
Reference values of thirty-one frequently used laboratory markers for 75-year-old males and females
Ryden, Ingvar; Lind, Lars
2012-01-01
Background We have previously reported reference values for common clinical chemistry tests in healthy 70-year-old males and females. We have now repeated this study 5 years later to establish reference values also at the age of 75. It is important to have adequate reference values for elderly patients as biological markers may change over time, and adequate reference values are essential for correct clinical decisions. Methods We have investigated 31 frequently used laboratory markers in 75-year-old males (n = 354) and females (n = 373) without diabetes. The 2.5 and 97.5 percentiles for these markers were calculated according to the recommendations of the International Federation of Clinical Chemistry. Results Reference values are reported for 75-year-old males and females for 31 frequently used laboratory markers. Conclusion There were minor differences between reference intervals calculated with and without individuals with cardiovascular diseases. Several of the reference intervals differed from Scandinavian reference intervals based on younger individuals (Nordic Reference Interval Project). PMID:22300333
NASA Technical Reports Server (NTRS)
Geimer, W.
1995-01-01
This report documents the final reliability prediction performed on the Earth Observing System/Advanced Microwave Sounding Unit-A (EOS/AMSU-A). The A1 Module contains Channels 3 through 15, and is referred to herein as 'EOS/AMSU-A1'. The A2 Module contains Channels 1 and 2, and is referred herein as 'EOS/AMSU-A2'. The 'specified' figures were obtained from Aerojet Reports 8897-1 and 9116-1. The predicted reliability figure for the EOS/AMSU-A1 meets the specified value and provides a Mean Time Between Failures (MTBF) of 74,390 hours. The predicted reliability figure for the EOS/AMSU-A2 meets the specified value and provides a MTBF of 193,110 hours.
Marinsky, J.A.; Reddy, M.M.
1990-01-01
The molecular weight and aggregation tendency of a reference-soil fulvic acid in Armadale horizon Bh were determined by vapor-pressure osmometry using tetrahydrofuran and water as solvents. With tetrahydrofuran, number-average molecular weight values of 767 ?? 34 and 699 ?? 8 daltons were obtained from two separate sets of measurements. Two sets of measurements with water also yielded values within this range (754 ?? 70 daltons) provided that the fulvic acid concentration in water did not exceed 7 mg ml-1; at higher concentrations (9.1-13.7 mg ml-1) a number-average molecular weight of 956 ?? 25 daltons was resolved, providing evidence of molecular aggregation. Extension of these studies to 80% neutralized fulvic acid showed that a sizeable fraction of the sodium counter ion is not osmotically active.
Reference values for muscle strength: a systematic review with a descriptive meta-analysis.
Benfica, Poliana do Amaral; Aguiar, Larissa Tavares; Brito, Sherindan Ayessa Ferreira de; Bernardino, Luane Helena Nunes; Teixeira-Salmela, Luci Fuscaldi; Faria, Christina Danielli Coelho de Morais
2018-05-03
Muscle strength is an important component of health. To describe and evaluate the studies which have established the reference values for muscle strength on healthy individuals and to synthesize these values with a descriptive meta-analysis approach. A systematic review was performed in MEDLINE, LILACS, and SciELO databases. Studies that investigated the reference values for muscle strength of two or more appendicular/axial muscle groups of health individuals were included. Methodological quality, including risk of bias was assessed by the QUADAS-2. Data extracted included: country of the study, sample size, population characteristics, equipment/method used, and muscle groups evaluated. Of the 414 studies identified, 46 were included. Most of the studies had adequate methodological quality. Included studies evaluated: appendicular (80.4%) and axial (36.9%) muscles; adults (78.3%), elderly (58.7%), adolescents (43.5%), children (23.9%); isometric (91.3%) and isokinetic (17.4%) strength. Six studies (13%) with similar procedures were synthesized with meta-analysis. Generally, the coefficient of variation values that resulted from the meta-analysis ranged from 20.1% to 30% and were similar to those reported by the original studies. The meta-analysis synthesized the reference values of isometric strength of 14 muscle groups of the dominant/non-dominant sides of the upper/lower limbs of adults/elderly from developed countries, using dynamometers/myometer. Most of the included studies had adequate methodological quality. The meta-analysis provided reference values for the isometric strength of 14 appendicular muscle groups of the dominant/non-dominant sides, measured with dynamometers/myometers, of men/women, of adults/elderly. These data may be used to interpret the results of the evaluations and establish appropriate treatment goals. Copyright © 2018 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.
Muraru, Denisa; Onciul, Sebastian; Peluso, Diletta; Soriani, Nicola; Cucchini, Umberto; Aruta, Patrizia; Romeo, Gabriella; Cavalli, Giacomo; Iliceto, Sabino; Badano, Luigi P
2016-02-01
Despite the fact that assessment of right ventricular longitudinal strain (RVLS) carries important implications for patient diagnosis, prognosis, and treatment, its implementation in clinical settings has been hampered by the limited reference values and the lack of uniformity in software, method, and definition used for measuring RVLS. Accordingly, this study was designed to establish (1) the reference values for RVLS by 2-dimensional speckle-tracking echocardiography; and (2) their relationship with demographic, hemodynamic, and cardiac factors. In 276 healthy volunteers (55% women; age, 18-76 years), free wall and septum RVLS (6 segments) and free wall RVLS (3 segments) using both 6- and 3-segment regions of interest were obtained. Feasibility of 6-segment RVLS was 92%. Free wall RVLS from 3- versus 6-segment regions of interest had similar values, yet 6-segment region of interest was more feasible (86% versus 73%; P<0.001) and reproducible. Reference values (lower limits of normality) were as follows: 6-segment RVLS, -24.7±2.6% (-20.0%) for men and -26.7±3.1% (-20.3%) for women; 3-segment RVLS, -29.3±3.4% (-22.5%) for men and -31.6±4.0% (-23.3%) for women (P<0.001). Free wall RVLS was 5±2 strain units (%) larger in magnitude than 6-segment RVLS, 10±4% larger than septal RVLS, and 2±4% larger in women than in men (P<0.001). At multivariable analysis, age, sex, pulmonary systolic pressure, right atrial minimal volume, as well as right atrial and left ventricular longitudinal strain resulted as correlates of RVLS values. This is the largest study providing sex- and method-specific reference values for RVLS. Our data may foster the implementation of 2-dimensional speckle-tracking echocardiography-derived RV analysis in clinical practice. © 2016 American Heart Association, Inc.
Reference Values for Cardiorespiratory Fitness and Incidence of Type 2 Diabetes
Kawakami, Ryoko; Sawada, Susumu S.; Matsushita, Munehiro; Okamoto, Takashi; Tsukamoto, Koji; Higuchi, Mitsuru; Miyachi, Motohiko
2014-01-01
Background In “Physical Activity Reference for Health Promotion 2013” the Japan Ministry of Health, Labour and Welfare publication gives reference values for cardiorespiratory fitness (CRF) required for good health. We examined the associations between the CRF reference values and incidence of type 2 diabetes. Methods This prospective cohort study enrolled 4633 nondiabetic Japanese men aged 20 to 39 years at baseline. CRF was measured using the cycle ergometer test, and maximal oxygen uptake was estimated. On the basis of the CRF reference value, participants were classified into 2 groups: those with values less than the reference value (under-RV) and those with values equal to or greater than reference value (over-RV). Hazard ratios (HRs) and 95% CIs for incident type 2 diabetes were estimated using a Cox proportional hazards model. Results A total of 266 participants developed type 2 diabetes during the 14 years of follow-up. As compared with the under-RV group, the over-RV group had a significantly lower multivariable-adjusted HR for type 2 diabetes (HR 0.67; 95% CI, 0.51–0.89). In receiver operating characteristic analysis, the optimal CRF cut-off value for predicting incident type 2 diabetes was 10.8 metabolic equivalents (sensitivity, 0.64; specificity, 0.64), which was close to the CRF reference value of 11.0 metabolic equivalents. Conclusions The reference CRF value appears to be reasonably valid for prevention of type 2 diabetes, especially among Japanese men younger than 40 years. Development of type 2 diabetes can be prevented by maintaining a CRF level above the reference value. PMID:24240630
Basri, Bazil; Griffin, Michael J
2014-11-01
The extent to which a seat can provide useful attenuation of vehicle vibration depends on three factors: the characteristics of the vehicle motion, the vibration transmissibility of the seat, and the sensitivity of the body to vibration. The 'seat effective amplitude transmissibility' (i.e., SEAT value) reflects how these three factors vary with the frequency and the direction of vibration so as to predict the vibration isolation efficiency of a seat. The SEAT value is mostly used to select seat cushions or seat suspensions based on the transmission of vertical vibration to the principal supporting surface of a seat. This study investigated the accuracy of SEAT values in predicting how seats with backrests influence the discomfort caused by multiple-input vibration. Twelve male subjects participated in a four-part experiment to determine equivalent comfort contours, the relative discomfort, the location of discomfort, and seat transmissibility with three foam seats and a rigid reference seat at 14 frequencies of vibration in the range 1-20 Hz at magnitudes of vibration from 0.2 to 1.6 ms(-2) r.m.s. The 'measured seat dynamic discomfort' (MSDD) was calculated for each foam seat from the ratio of the vibration acceleration required to cause similar discomfort with the foam seat and with the rigid reference seat. Using the frequency weightings in current standards, the SEAT values of each seat were calculated from the ratio of overall ride values with the foam seat to the overall ride values with the rigid reference seat, and compared to the corresponding MSDD at each frequency. The SEAT values provided good predictions of how the foam seats increased vibration discomfort at frequencies around the 4-Hz resonance but reduced vibration discomfort at frequencies greater than about 6.3 Hz, with discrepancies explained by a known limitation of the frequency weightings. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.
The Neurobiology of Reference-Dependent Value Computation
De Martino, Benedetto; Kumaran, Dharshan; Holt, Beatrice; Dolan, Raymond J.
2009-01-01
A key focus of current research in neuroeconomics concerns how the human brain computes value. Although, value has generally been viewed as an absolute measure (e.g., expected value, reward magnitude), much evidence suggests that value is more often computed with respect to a changing reference point, rather than in isolation. Here, we present the results of a study aimed to dissociate brain regions involved in reference-independent (i.e., “absolute”) value computations, from those involved in value computations relative to a reference point. During functional magnetic resonance imaging, subjects acted as buyers and sellers during a market exchange of lottery tickets. At a behavioral level, we demonstrate that subjects systematically accorded a higher value to objects they owned relative to those they did not, an effect that results from a shift in reference point (i.e., status quo bias or endowment effect). Our results show that activity in orbitofrontal cortex and dorsal striatum track parameters such as the expected value of lottery tickets indicating the computation of reference-independent value. In contrast, activity in ventral striatum indexed the degree to which stated prices, at a within-subjects and between-subjects level, were distorted with respect to a reference point. The findings speak to the neurobiological underpinnings of reference dependency during real market value computations. PMID:19321780
Reference values for 27 clinical chemistry tests in 70-year-old males and females.
Carlsson, Lena; Lind, Lars; Larsson, Anders
2010-01-01
Reference values are usually defined based on blood samples from healthy men or nonpregnant women in the age range of 20-50 years. These values are not optimal for elderly patients, as many biological markers change over time and adequate reference values are important for correct clinical decisions. To validate NORIP (Nordic Reference Interval Project) reference values in a 70-year-old population. We studied 27 frequently used laboratory tests. The 2.5th and 97.5th percentiles for these markers were calculated according to the recommendations of the International Federation of Clinical Chemistry on the statistical treatment of reference values. Reference values are reported for plasma alanine aminotransferase, albumin, alkaline phosphatase, pancreas amylase, apolipoprotein A1, apolipoprotein B, aspartate aminotransferase, bilirubin, calcium, chloride, cholesterol, creatinine, creatine kinase, C-reactive protein, glucose, gamma-glutamyltransferase, HDL-cholesterol, iron, lactate dehydrogenase, LDL-cholesterol, magnesium, phosphate, potassium, sodium, transferrin, triglycerides, urate and urea. Reference values calculated from the whole population and a subpopulation without cardiovascular disease showed strong concordance. Several of the reference interval limits were outside the 90% CI of a Scandinavian population (NORIP). 2009 S. Karger AG, Basel.
Qureshi, Waqas T.; Leigh, J. Adam; Swett, Katrina; Ajay, Dharod; Allison, Matthew A.; Cai, Jianwen; Gonzalez, Franklyn; Hurwitz, Barry E.; Shah, Sanjiv J.; Desai, Ankit A.; Spevack, Daniel M.; Rodriguez, Carlos J.
2015-01-01
Background Reference limits for echocardiographic quantification of cardiac chambers in Hispanics are not well studied. Methods and Results We examined the reference values of left atrium (LA) and ventricle (LV) structure in a large ethnically diverse Hispanic cohort. Two-dimensional transthoracic echocardiography was performed in 1,818 participants of the Echocardiographic Study of Latinos (ECHO-SOL). Individuals with body mass index ≥30kg/m2, hypertension, diabetes mellitus, coronary artery disease and atrial fibrillation were excluded leaving 525 participants defined as healthy reference-cohort. We estimated 95th weighted percentiles of LV end systolic volume, LV end diastolic volume, relative wall and septal thickness, LV mass and left atrial volume. We then used upper reference limits of the 2005 and 2015 American Society of Echocardiography (ASE) and 95th percentile of reference cohort to classify the Hispanic Community Health Study/Study of Latinos (HCHS/SOL) target population into abnormal and normal. Reference limits were also calculated for each of 6 Hispanic origins. Using ASE 2015 defined reference values we categorized 7%, 21%, 57% and 17% of males and 18%, 29%, 60% and 26% of females as having abnormal LV mass index, relative, septal and posterior wall thickness, respectively. Conversely, 10%, and 11% of males and 4% and 2% of females were classified as having abnormal end-diastolic volume and internal diameter by ASE 2015 cut-offs, respectively. Similar differences were found when we used 2005 ASE cut offs. Several differences were noted in distribution of cardiac structure and volumes among various Hispanic/Latino origins. Cubans had highest values of echocardiographic measures and Central Americans had the lowest. Conclusions This is the first large study that provides normal reference values for cardiac structure. It further demonstrates that a considerable segment of Hispanic/Latinos residing in US may be classified as having abnormal measures of cardiac chambers when 2015 and 2005 ASE reference cut-offs are used. PMID:26712159
Kaminsky, Leonard A; Imboden, Mary T; Arena, Ross; Myers, Jonathan
2017-02-01
The importance of cardiorespiratory fitness (CRF) is well established. This report provides newly developed standards for CRF reference values derived from cardiopulmonary exercise testing (CPX) using cycle ergometry in the United States. Ten laboratories in the United States experienced in CPX administration with established quality control procedures contributed to the "Fitness Registry and the Importance of Exercise: A National Database" (FRIEND) Registry from April 2014 through May 2016. Data from 4494 maximal (respiratory exchange ratio, ≥1.1) cycle ergometer tests from men and women (20-79 years) from 27 states, without cardiovascular disease, were used to develop these references values. Percentiles of maximum oxygen consumption (VO 2max ) for men and women were determined for each decade from age 20 years through age 79 years. Comparisons of VO 2max were made to reference data established with CPX data from treadmill data in the FRIEND Registry and previously published reports. As expected, there were significant differences between sex and age groups for VO 2max (P<.01). For cycle tests within the FRIEND Registry, the 50th percentile VO 2max of men and women aged 20 to 29 years declined from 41.9 and 31.0 mLO 2 /kg/min to 19.5 and 14.8 mLO 2 /kg/min for ages 70 to 79 years, respectively. The rate of decline in this cohort was approximately 10% per decade. The FRIEND Registry reference data will be useful in providing more accurate interpretations for the US population of CPX-measured VO 2max from exercise tests using cycle ergometry compared with previous approaches based on estimations of standard differences from treadmill testing reference values. Copyright © 2016 Mayo Foundation for Medical Education and Research. All rights reserved.
INHALATION EXPOSURE-RESPONSE METHODOLOGY
The Inhalation Exposure-Response Analysis Methodology Document is expected to provide guidance on the development of the basic toxicological foundations for deriving reference values for human health effects, focusing on the hazard identification and dose-response aspects of the ...
Wack, Raymund F; Hansen, Eric; Small, Marilyn; Poppenga, Robert; Bunn, David; Johnson, Christine K
2012-04-01
Hematology and plasma biochemistry parameters are useful in the assessment and management of threatened and endangered species. Although reference ranges are readily available for many mammalian species, reference ranges for snakes are lacking for most species. We determined hematology and plasma biochemistry reference ranges for giant garter snakes (Thamnophis gigas) and valley garter snakes (Thamnophis sirtalis fitchi) living in four management areas in the Central Valley of California. White blood cell, heterophil, lymphocyte, and azurophil counts in giant garter snakes were approximately twice the values of valley garter snakes. Statistically significant differences in aspartate aminotransferase, globulin, and potassium between the two species did not appear clinically significant. No significant differences were found in the measured parameters between male and female giant garter snakes. Some differences were found among collection sites. These reference ranges provide baseline data for comparisons over time and between collection sites.
A tri-reference point theory of decision making under risk.
Wang, X T; Johnson, Joseph G
2012-11-01
The tri-reference point (TRP) theory takes into account minimum requirements (MR), the status quo (SQ), and goals (G) in decision making under risk. The 3 reference points demarcate risky outcomes and risk perception into 4 functional regions: success (expected value of x ≥ G), gain (SQ < × < G), loss (MR ≤ x < SQ), and failure (x < MR). The psychological impact of achieving or failing to achieve these reference points is rank ordered as MR > G > SQ. We present TRP assumptions and value functions and a mathematical formalization of the theory. We conducted empirical tests of crucial TRP predictions using both explicit and implicit reference points. We show that decision makers consider both G and MR and give greater weight to MR than G, indicating failure aversion (i.e., the disutility of a failure is greater than the utility of a success in the same task) in addition to loss aversion (i.e., the disutility of a loss is greater than the utility of the same amount of gain). Captured by a double-S shaped value function with 3 inflection points, risk preferences switched between risk seeking and risk aversion when the distribution of a gamble straddled a different reference point. The existence of MR (not G) significantly shifted choice preference toward risk aversion even when the outcome distribution of a gamble was well above the MR. Single reference point based models such as prospect theory cannot consistently account for these findings. The TRP theory provides simple guidelines for evaluating risky choices for individuals and organizational management. (PsycINFO Database Record (c) 2012 APA, all rights reserved).
Monakhova, Yulia B; Kohl-Himmelseher, Matthias; Kuballa, Thomas; Lachenmeier, Dirk W
2014-11-01
A fast and reliable nuclear magnetic resonance spectroscopic method for quantitative determination (qNMR) of targeted molecules in reference materials has been established using the ERETIC2 methodology (electronic reference to access in vivo concentrations) based on the PULCON principle (pulse length based concentration determination). The developed approach was validated for the analysis of pharmaceutical samples in the context of official medicines control, including ibandronic acid, amantadine, ambroxol and lercanidipine. The PULCON recoveries were above 94.3% and coefficients of variation (CVs) obtained by quantification of different targeted resonances ranged between 0.7% and 2.8%, demonstrating that the qNMR method is a precise tool for rapid quantification (approximately 15min) of reference materials and medicinal products. Generally, the values were within specification (certified values) provided by the manufactures. The results were in agreement with NMR quantification using an internal standard and validated reference HPLC analysis. The PULCON method was found to be a practical alternative with competitive precision and accuracy to the classical internal reference method and it proved to be applicable to different solvent conditions. The method can be recommended for routine use in medicines control laboratories, especially when the availability and costs of reference compounds are problematic. Copyright © 2014 Elsevier B.V. All rights reserved.
Miyashita, Shin-ichi; Inagaki, Kazumi; Narukawa, Tomohiro; Zhu, Yanbei; Kuroiwa, Takayoshi; Hioki, Akiharu; Chiba, Koichi
2012-01-01
A certified reference material (CRM) for trace cadmium and other elements in brown rice flour was developed at the National Metrology Institute of Japan (NMIJ). The CRM was provided as a dry powder after drying and frozen pulverization of fresh brown rice obtained from a Japanese domestic market. Characterization of the property value for each element was carried out exclusively by NMIJ with at least two independent analytical methods, including inductively coupled plasma mass spectrometry (ICP-MS), ICP high-resolution mass spectrometry, isotope-dilution ICP-MS, ICP optical emission spectrometry, and graphite-furnace atomic-absorption spectrometry. Property values were provided for six elements (Mn, Fe, Cu, Zn, As, and Cd). The concentration range of the property values was from 0.280 mg kg(-1) of As to 31.8 mg kg(-1) of Zn. The combined relative standard uncertainties of the property values were estimated by considering the uncertainties of the homogeneity, characterization, difference among analytical methods, dry-mass correction factor, and calibration standard. The range of the relative combined standard uncertainties was from 1.1% of Zn to 1.6% of As.
Validated age-specific reference values for CSF total protein levels in children.
Kahlmann, V; Roodbol, J; van Leeuwen, N; Ramakers, C R B; van Pelt, D; Neuteboom, R F; Catsman-Berrevoets, C E; de Wit, M C Y; Jacobs, B C
2017-07-01
To define age-specific reference values for cerebrospinal fluid (CSF) total protein levels for children and validate these values in children with Guillain-Barré syndrome (GBS), acute disseminated encephalomyelitis (ADEM) and multiple sclerosis (MS). Reference values for CSF total protein levels were determined in an extensive cohort of diagnostic samples from children (<18 year) evaluated at Erasmus Medical Center/Sophia Children's Hospital. These reference values were confirmed in children diagnosed with disorders unrelated to raised CSF total protein level and validated in children with GBS, ADEM and MS. The test results of 6145 diagnostic CSF samples from 3623 children were used to define reference values. The reference values based on the upper limit of the 95% CI (i.e. upper limit of normal) were for 6 months-2 years 0.25 g/L, 2-6 years 0.25 g/L, 6-12 years 0.28 g/L, 12-18 years 0.34 g/L. These reference values were confirmed in a subgroup of 378 children diagnosed with disorders that are not typically associated with increased CSF total protein. In addition, the CSF total protein levels in these children in the first 6 months after birth were highly variable (median 0.47 g/L, IQR 0.26-0.65). According to these new reference values, CSF total protein level was elevated in 85% of children with GBS, 66% with ADEM and 23% with MS. More accurate age-specific reference values for CSF total protein levels in children were determined. These new reference values are more sensitive than currently used values for diagnosing GBS and ADEM in children. Copyright © 2017 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.
Hematology, plasma chemistry, and bacteriology of wild Tundra Swans (Cygnus columbianus) in Alaska.
Milani, Juliana F; Wilson, Heather; Ziccardi, Michael; LeFebvre, Rance; Scott, Cheryl
2012-01-01
Blood and cloacal swabs were collected from 100 (66 female, 34 male) wild Tundra Swans (Cygnus columbianus) molting in northwestern Alaska, USA, 25-28 July 2008, to establish hematologic and serum chemistry reference values and to isolate enteric Salmonella spp. and Escherichia coli O157:H7. Plasma biochemistry and hematology values did not vary significantly by sex or age. Tundra swans had high levels of creatine kinase, lactate dehydrogenase, amylase, and alkaline phosphatase compared with some other avian species (values were up to 7 times greater), possibly indicating capture myopathy. However, concentrations were much lower (up to 8 times lower) than in other waterfowl exposed to similar or more intensive capture methods. White blood cell count and hematocrit values were similar to other waterfowl species, and enteric Salmonella spp. and E. coli O157:H7 were not present among birds sampled. Our data provide the first biochemical, hematologic, and bacteriologic reference values for wild Tundra Swans.
Adeli, Khosrow; Higgins, Victoria; Nieuwesteeg, Michelle; Raizman, Joshua E; Chen, Yunqi; Wong, Suzy L; Blais, David
2015-08-01
Biological covariates such as age and sex can markedly influence biochemical marker reference values, but no comprehensive study has examined such changes across pediatric, adult, and geriatric ages. The Canadian Health Measures Survey (CHMS) collected comprehensive nationwide health information and blood samples from children and adults in the household population and, in collaboration with the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER), examined biological changes in biochemical markers from pediatric to geriatric age, establishing a comprehensive reference interval database for routine disease biomarkers. The CHMS collected health information, physical measurements, and biosamples (blood and urine) from approximately 12 000 Canadians aged 3-79 years and measured 24 biochemical markers with the Ortho Vitros 5600 FS analyzer or a manual microplate. By use of CLSI C28-A3 guidelines, we determined age- and sex-specific reference intervals, including corresponding 90% CIs, on the basis of specific exclusion criteria. Biochemical marker reference values exhibited dynamic changes from pediatric to geriatric age. Most biochemical markers required some combination of age and/or sex partitioning. Two or more age partitions were required for all analytes except bicarbonate, which remained constant throughout life. Additional sex partitioning was required for most biomarkers, except bicarbonate, total cholesterol, total protein, urine iodine, and potassium. Understanding the fluctuations in biochemical markers over a wide age range provides important insight into biological processes and facilitates clinical application of biochemical markers to monitor manifestation of various disease states. The CHMS-CALIPER collaboration addresses this important evidence gap and allows the establishment of robust pediatric and adult reference intervals. © 2015 American Association for Clinical Chemistry.
Choice of Reference Serum Creatinine in Defining AKI
Siew, Edward D.; Matheny, Michael E.
2015-01-01
Background/Aims The study of acute kidney injury (AKI) has expanded with the increasing availability of electronic health records and the use of standardized definitions. Understanding the impact of AKI between settings is limited by heterogeneity in the selection of reference creatinine to anchor the definition of AKI. In this mini-review, we discuss different approaches used to select reference creatinine and their relative merits and limitations. Methods We reviewed the literature to obtain representative examples of published baseline creatinine definitions when pre-hospital data were not available, as well as literature evaluating estimation of baseline renal function, using Pubmed and reference back-tracing within known works. Results 1) Prehospital creatinine values are useful in determining reference creatinine, and in high-risk populations, the mean outpatient serum creatinine value 7-365 days before hospitalization closely approximates nephrology adjudication, 2) in patients without pre-hospital data, the eGFR 75 approach does not reliably estimate true AKI incidence in most at-risk populations 3) using the lowest inpatient serum creatinine may be reasonable, especially in those with preserved kidney function, but may generously estimate AKI incidence and severity and miss community-acquired AKI that does not fully resolve, 4) using more specific definitions of AKI (e.g. KIDGO Stage 2 and 3) may help to reduce the effects of misclassification when using surrogate values, and 5) leveraging available clinical data may help refine the estimate of reference creatinine. Conclusions Choosing reference creatinine for AKI calculation is important for AKI classification and study interpretation. We recommend obtaining data on pre-hospital kidney function, wherever possible. In studies where surrogate estimates are used, transparency in how they are applied and discussion that informs the reader of potential biases should be provided. Further work to refine the estimation of reference creatinine is needed. PMID:26332325
The Value in Evaluating and Communicating Program Impact: The Ohio BR&E Program
ERIC Educational Resources Information Center
Daivs, Gregory
2012-01-01
Assessing program impact can provide useful program evaluation data. It also provides a basis for program development, marketing, and justification. This article discusses recent impact evaluation efforts and findings of a long-time Extension program; referred to as Business Retention and Expansion (BR&E). How such information can be…
Reference values for pulse oximetry at high altitude
Gamponia, M; Babaali, H; Yugar, F; Gilman, R
1998-01-01
OBJECTIVE—To determine reference values for oxygen saturation (SaO2) in healthy children younger than 5 years living at high altitude. DESIGN—One hundred and sixty eight children were examined for SaO2 at 4018 m during well child visits. Physiological state was also noted during the examination. RESULTS—The mean SaO2 was 87.3% (95% confidence intervals (CI) 86.7%, 87.9%) with a median value of 87.7%. A significant difference was observed in SaO2 between children younger than 1 year compared with older children, although the difference was no longer demonstrable when sleeping children were excluded. CONCLUSIONS—This study has provided a reference range of SaO2 values for healthy children under 5 years old so that pulse oximetry may be used as an adjunct in diagnosing acute respiratory infections. Younger children were also shown to have a lower mean SaO2 than older children living at high altitude, which suggests physiological adaptation to high altitude over time. In addition, sleep had a lowering effect on SaO2, although the clinical importance of this remains undetermined. PMID:9659095
Professional nursing values: A concept analysis.
Schmidt, Bonnie J; McArthur, Erin C
2018-01-01
The aim of this concept analysis is to clarify the meaning of professional nursing values. In a time of increasing ethical dilemmas, it is essential that nurses internalize professional values to develop and maintain a professional identity. However, nursing organizations and researchers provide different conceptions of professional nursing values, leading to a lack of clarity as to the meaning and attributes of this construct. Walker and Avant's (2011) method was used to guide an analysis of this concept. Resources published from 1973 to 2016 were identified via electronic databases and hand-searching of reference lists. A review of the literature was completed and the data were analyzed to identify uses of the concept; the defining attributes of the concept; borderline, related, contrary, and illegitimate examples; antecedents and consequences; and empirical referents. Professional nursing values were defined as important professional nursing principles of human dignity, integrity, altruism, and justice that serve as a framework for standards, professional practice, and evaluation. Further research is needed in the development and testing of professional nursing values theory, and the reassessment of values instruments. Core professional values that are articulated may help unify the profession and demonstrate the value of nursing to the public. © 2017 Wiley Periodicals, Inc.
Wadwa, R Paul; Laffel, Lori M; Shah, Viral N; Garg, Satish K
2018-06-01
Frequent use of continuous glucose monitoring (CGM) systems is associated with improved glycemic outcomes in persons with diabetes, but the need for calibrations and sensor insertions are often barriers to adoption. In this study, we evaluated the performance of G6, a sixth-generation, factory-calibrated CGM system specified for 10-day wear. The study enrolled participants of ages 6 years and up with type 1 diabetes or insulin-treated type 2 diabetes at 11 sites in the United States. Participation involved one sensor wear period of up to 10 days. Adults wore the system on the abdomen; youth of ages 6-17 years could choose to wear it on the abdomen or upper buttocks. Clinic sessions for frequent comparison with reference blood glucose measurements took place on days 1, 4-5, 7, and/or 10. Participants of ages 13 years and up underwent purposeful supervised glucose manipulation during in-clinic sessions. During the study, participants calibrated the systems once daily. However, analysis was performed on glucose values that were derived from reprocessed raw sensor data, independently of self-monitored blood glucose values used for calibration. Reprocessing used assigned sensor codes and a factory-calibration algorithm. Performance evaluation included the proportion of CGM values that were within ±20% of reference glucose values >100 mg/dL or within ±20 mg/dL of reference glucose values ≤100 mg/dL (%20/20), the analogous %15/15, and the mean absolute relative difference (MARD, expressed as a percentage) between temporally matched CGM and reference values. Data from 262 study participants (21,569 matched CGM reference pairs) were analyzed. The overall %15/15, %20/20, and MARD were 82.4%, 92.3%, and 10.0%, respectively. Matched pairs from 134 adults and 128 youth of ages 6-17 years were similar with respect to %20/20 (92.4% and 91.9%) and MARD (9.9% and 10.1%). Overall %20/20 values on days 1 and 10 of sensor wear were 88.6% and 90.6%, respectively. The system's "Urgent Low Soon" (predictive of hypoglycemia within 20 min) hypoglycemia alert was correctly provided 84% of the time within 30 min before impending biochemical hypoglycemia (<70 mg/dL). The 10-day sensor survival rate was 87%. The new factory-calibrated G6 real-time CGM system provides accurate readings for 10 days and removes several clinical barriers to broader CGM adoption.
2013-01-01
Background The measurement of the Erythrocyte Sedimentation Rate (ESR) value is a standard procedure performed during a typical blood test. In order to formulate a unified standard of establishing reference ESR values, this paper presents a novel prediction model in which local normal ESR values and corresponding geographical factors are used to predict reference ESR values using multi-layer feed-forward artificial neural networks (ANN). Methods and findings Local normal ESR values were obtained from hospital data, while geographical factors that include altitude, sunshine hours, relative humidity, temperature and precipitation were obtained from the National Geographical Data Information Centre in China. The results show that predicted values are statistically in agreement with measured values. Model results exhibit significant agreement between training data and test data. Consequently, the model is used to predict the unseen local reference ESR values. Conclusions Reference ESR values can be established with geographical factors by using artificial intelligence techniques. ANN is an effective method for simulating and predicting reference ESR values because of its ability to model nonlinear and complex relationships. PMID:23497145
Yang, Qingsheng; Mwenda, Kevin M; Ge, Miao
2013-03-12
The measurement of the Erythrocyte Sedimentation Rate (ESR) value is a standard procedure performed during a typical blood test. In order to formulate a unified standard of establishing reference ESR values, this paper presents a novel prediction model in which local normal ESR values and corresponding geographical factors are used to predict reference ESR values using multi-layer feed-forward artificial neural networks (ANN). Local normal ESR values were obtained from hospital data, while geographical factors that include altitude, sunshine hours, relative humidity, temperature and precipitation were obtained from the National Geographical Data Information Centre in China.The results show that predicted values are statistically in agreement with measured values. Model results exhibit significant agreement between training data and test data. Consequently, the model is used to predict the unseen local reference ESR values. Reference ESR values can be established with geographical factors by using artificial intelligence techniques. ANN is an effective method for simulating and predicting reference ESR values because of its ability to model nonlinear and complex relationships.
Managing imperfect competition by pay for performance and reference pricing.
Mak, Henry Y
2018-01-01
I study a managed health service market where differentiated providers compete for consumers by choosing multiple service qualities, and where copayments that consumers pay and payments that providers receive for services are set by a payer. The optimal regulation scheme is two-sided. On the demand side, it justifies and clarifies value-based reference pricing. On the supply side, it prescribes pay for performance when consumers misperceive service benefits or providers have intrinsic quality incentives. The optimal bonuses are expressed in terms of demand elasticities, service technology, and provider characteristics. However, pay for performance may not outperform prospective payment when consumers are rational and providers are profit maximizing, or when one of the service qualities is not contractible. Copyright © 2017 Elsevier B.V. All rights reserved.
Miller, Robert; Stalder, Tobias; Jarczok, Marc; Almeida, David M; Badrick, Ellena; Bartels, Meike; Boomsma, Dorret I; Coe, Christopher L; Dekker, Marieke C J; Donzella, Bonny; Fischer, Joachim E; Gunnar, Megan R; Kumari, Meena; Lederbogen, Florian; Power, Christine; Ryff, Carol D; Subramanian, S V; Tiemeier, Henning; Watamura, Sarah E; Kirschbaum, Clemens
2016-11-01
Diurnal salivary cortisol profiles are valuable indicators of adrenocortical functioning in epidemiological research and clinical practice. However, normative reference values derived from a large number of participants and across a wide age range are still missing. To fill this gap, data were compiled from 15 independently conducted field studies with a total of 104,623 salivary cortisol samples obtained from 18,698 unselected individuals (mean age: 48.3 years, age range: 0.5-98.5 years, 39% females). Besides providing a descriptive analysis of the complete dataset, we also performed mixed-effects growth curve modeling of diurnal salivary cortisol (i.e., 1-16h after awakening). Cortisol decreased significantly across the day and was influenced by both, age and sex. Intriguingly, we also found a pronounced impact of sampling season with elevated diurnal cortisol in spring and decreased levels in autumn. However, the majority of variance was accounted for by between-participant and between-study variance components. Based on these analyses, reference ranges (LC/MS-MS calibrated) for cortisol concentrations in saliva were derived for different times across the day, with more specific reference ranges generated for males and females in different age categories. This integrative summary provides important reference values on salivary cortisol to aid basic scientists and clinicians in interpreting deviations from the normal diurnal cycle. Copyright © 2016 Elsevier Ltd. All rights reserved.
Glycaemic index and glycaemic load values of commonly consumed foods in the United Arab Emirates.
Al Dhaheri, Ayesha S; Henry, C Jeyakumar K; Mohamad, Maysm N; Ohuma, Eric O; Ismail, Leila Cheikh; Al Meqbaali, Fatima T; Jarrar, Amjad H
2017-04-01
Glycaemic index (GI) and glycaemic load (GL) values of some commonly consumed foods in the United Arab Emirates were determined with an aim of adding these values to the existing international table of GI and GL values. In all, eighteen test foods categorised into breads (n 5), entrée dishes (n 3), main dishes (n 5) and sweet dishes (n 5) were tested. For each test food, at least fifteen healthy participants consumed 25 or 50 g available carbohydrate portions of a reference food (glucose), which was tested three times, and a test food after an overnight fast, was tested once, on separate occasions. Capillary blood samples were obtained by finger-prick and blood glucose was measured using clinical chemistry analyser. A fasting blood sample was obtained at baseline and before consumption of test foods. Additional blood samples were obtained at 15, 30, 45, 60, 90 and 120 min after the consumption of each test food. The GI value of each test food was calculated as the percentage of the incremental area under the blood glucose curve (IAUC) for the test food of each participant divided by the average IAUC for the reference food of the same participant. The GI values of tested foods ranged from low (55 or less) to high (70 or more). The GI values of various breads and rice-containing dishes were comparable with previously published values. This study provides GI and GL values of previously untested traditional Emirati foods which could provide a useful guide on dietary recommendations for the Emirati population.
Revised reference values for selenium intake.
Kipp, A P; Strohm, D; Brigelius-Flohé, R; Schomburg, L; Bechthold, A; Leschik-Bonnet, E; Heseker, H
2015-10-01
The German, Austrian and Swiss nutrition societies are the joint editors of the 'reference values for nutrient intake'. They have revised the reference values for the intake of selenium and published them in February 2015. The saturation of selenoprotein P (SePP) in plasma is used as a criterion for the derivation of reference values for selenium intake in adults. For persons from selenium-deficient regions (China) SePP saturation was achieved with a daily intake of 49μg of selenium. When using the reference body weights the D-A-CH reference values are based upon, the resulting estimated value for selenium intake is 70μg/day for men and 60μg/day for women. The estimated value for selenium intake for children and adolescents is extrapolated using the estimated value for adults in relation to body weight. For infants aged 0 to under 4 months the estimated value of 10μg/day was derived from the basis of selenium intake via breast milk. For infants aged 4 to under 12 months this estimated value was used and taking into account the differences regarding body weight an estimated value of 15μg/day was derived. For lactating women compared to non-lactating women a higher reference value of 75μg/day is indicated due to the release of selenium with breast milk. The additional selenium requirement for pregnant women is negligible, so that no increased reference value is indicated. Copyright © 2015 The Authors. Published by Elsevier GmbH.. All rights reserved.
Mars Global Reference Atmospheric Model (Mars-GRAM) Version 3.8: Users Guide
NASA Astrophysics Data System (ADS)
Justus, C. G.; James, B. F.
1999-05-01
Mars Global Reference Atmospheric Model (Mars-GRAM) Version 3.8 is presented and its new features are discussed. Mars-GRAM uses new values of planetary reference ellipsoid radii, gravity term, and rotation rate (consistent with current JPL values) and includes centrifugal effects on gravity. The model now uses NASA Ames Global Circulation Model low resolution topography. Curvature corrections are applied to winds and limits based on speed of sound are applied. Altitude of the F1 ionization peak and density scale height, including effects of change of molecular weight with altitude are computed. A check is performed to disallow temperatures below CO2 sublimination. This memorandum includes instructions on obtaining Mars-GRAM source code and data files and running the program. Sample input and output are provided. An example of incorporating Mars-GRAM as an atmospheric subroutine in a trajectory code is also given.
Mars Global Reference Atmospheric Model (Mars-GRAM) Version 3.8: Users Guide
NASA Technical Reports Server (NTRS)
Justus, C. G.; James, B. F.
1999-01-01
Mars Global Reference Atmospheric Model (Mars-GRAM) Version 3.8 is presented and its new features are discussed. Mars-GRAM uses new values of planetary reference ellipsoid radii, gravity term, and rotation rate (consistent with current JPL values) and includes centrifugal effects on gravity. The model now uses NASA Ames Global Circulation Model low resolution topography. Curvature corrections are applied to winds and limits based on speed of sound are applied. Altitude of the F1 ionization peak and density scale height, including effects of change of molecular weight with altitude are computed. A check is performed to disallow temperatures below CO2 sublimination. This memorandum includes instructions on obtaining Mars-GRAM source code and data files and running the program. Sample input and output are provided. An example of incorporating Mars-GRAM as an atmospheric subroutine in a trajectory code is also given.
Anomaly-specified virtual dimensionality
NASA Astrophysics Data System (ADS)
Chen, Shih-Yu; Paylor, Drew; Chang, Chein-I.
2013-09-01
Virtual dimensionality (VD) has received considerable interest where VD is used to estimate the number of spectral distinct signatures, denoted by p. Unfortunately, no specific definition is provided by VD for what a spectrally distinct signature is. As a result, various types of spectral distinct signatures determine different values of VD. There is no one value-fit-all for VD. In order to address this issue this paper presents a new concept, referred to as anomaly-specified VD (AS-VD) which determines the number of anomalies of interest present in the data. Specifically, two types of anomaly detection algorithms are of particular interest, sample covariance matrix K-based anomaly detector developed by Reed and Yu, referred to as K-RXD and sample correlation matrix R-based RXD, referred to as R-RXD. Since K-RXD is only determined by 2nd order statistics compared to R-RXD which is specified by statistics of the first two orders including sample mean as the first order statistics, the values determined by K-RXD and R-RXD will be different. Experiments are conducted in comparison with widely used eigen-based approaches.
Han, Der-Sheng; Huang, Chi-Huang; Chen, Ssu-Yuan; Yang, Wei-Shiung
2017-01-01
Myostatin negatively regulates muscle growth, and its inhibition by suitable proteins can increase muscle bulk and exercise performance. However, the reference values of serum myostatin in athletes performing strength training are still lacking. A cross-sectional study recruiting28 male collegiate athletes performing strength training and 29 age-matched normal controls was conducted. The serum concentration of myostatin and insulin-like growth factor 1 (IGF-1), grip strength, and body composition were the main outcome measures. We used regression models to analyze the correlation between serum markers and the physiological parameters. The athlete group had greater height, weight, body mass index (BMI), fat mass percentage, fat-free mass, muscle mass, waist girth, grip strength, and estimated daily energy expenditure. The IGF-1 concentration was higher in the athlete group (324 ± 80 vs. 263 ± 134 ng/ml), but the myostatin levels did not differ (12.1 ± 3.7 vs. 12.4 ± 3.5 ng/ml). The reference value for IGF-1 among the healthy young males was 293 ± 114 ng/ml, correlated with age and height; the value for myostatin was 12.3 ± 3.6 ng/ml, correlated negatively with BMI, fat mass percentage, and waist girth after adjustment for age. Myostatin level is negatively related to fat percentage, and serum IGF-1 is positively related to height. The reference values could provide a basis for future doping-related study.
Expressing analytical performance from multi-sample evaluation in laboratory EQA.
Thelen, Marc H M; Jansen, Rob T P; Weykamp, Cas W; Steigstra, Herman; Meijer, Ron; Cobbaert, Christa M
2017-08-28
To provide its participants with an external quality assessment system (EQAS) that can be used to check trueness, the Dutch EQAS organizer, Organization for Quality Assessment of Laboratory Diagnostics (SKML), has innovated its general chemistry scheme over the last decade by introducing fresh frozen commutable samples whose values were assigned by Joint Committee for Traceability in Laboratory Medicine (JCTLM)-listed reference laboratories using reference methods where possible. Here we present some important innovations in our feedback reports that allow participants to judge whether their trueness and imprecision meet predefined analytical performance specifications. Sigma metrics are used to calculate performance indicators named 'sigma values'. Tolerance intervals are based on both Total Error allowable (TEa) according to biological variation data and state of the art (SA) in line with the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Milan consensus. The existing SKML feedback reports that express trueness as the agreement between the regression line through the results of the last 12 months and the values obtained from reference laboratories and calculate imprecision from the residuals of the regression line are now enriched with sigma values calculated from the degree to which the combination of trueness and imprecision are within tolerance limits. The information and its conclusion to a simple two-point scoring system are also graphically represented in addition to the existing difference plot. By adding sigma metrics-based performance evaluation in relation to both TEa and SA tolerance intervals to its EQAS schemes, SKML provides its participants with a powerful and actionable check on accuracy.
Peplies, J; Jiménez-Pavón, D; Savva, S C; Buck, C; Günther, K; Fraterman, A; Russo, P; Iacoviello, L; Veidebaum, T; Tornaritis, M; De Henauw, S; Mårild, S; Molnár, D; Moreno, L A; Ahrens, W
2014-09-01
The aim of this study is to present age- and sex-specific reference values of insulin, glucose, glycosylated haemoglobin (HbA1c) and the homeostasis model assessment to quantify insulin resistance (HOMA-IR) for pre-pubertal children. The reference population consists of 7074 normal weight 3- to 10.9-year-old pre-pubertal children from eight European countries who participated in at least one wave of the IDEFICS ('identification and prevention of dietary- and lifestyle-induced health effects in children and infants') surveys (2007-2010) and for whom standardised laboratory measurements were obtained. Percentile curves of insulin (measured by an electrochemiluminescence immunoassay), glucose, HbA1c and HOMA-IR were calculated as a function of age stratified by sex using the general additive model for location scale and shape (GAMLSS) method. Levels of insulin, fasting glucose and HOMA-IR continuously show an increasing trend with age, whereas HbA1c shows an upward trend only beyond the age of 8 years. Insulin and HOMA-IR values are higher in girls of all age groups, whereas glucose values are slightly higher in boys. Median serum levels of insulin range from 17.4 and 13.2 pmol l(-1) in 3-<3.5-year-old girls and boys, respectively, to 53.5 and 43.0 pmol l(-1) in 10.5-<11-year-old girls and boys. Median values of glucose are 4.3 and 4.5 mmol l(-1) in the youngest age group and 49.3 and 50.6 mmol l(-1) in the oldest girls and boys. For HOMA-IR, median values range from 0.5 and 0.4 in 3-<3.5-year-old girls and boys to 1.7 and 1.4 in 10.5-<11-year-old girls and boys, respectively. Our study provides the first standardised reference values for an international European children's population and provides the, up to now, largest data set of healthy pre-pubertal children to model reference percentiles for markers of insulin resistance. Our cohort shows higher values of Hb1Ac as compared with a single Swedish study while our percentiles for the other glucose metabolic markers are in good accordance with previous studies.
Reference values for pulmonary diffusing capacity for adult native Finns.
Kainu, Annette; Toikka, Jyri; Vanninen, Esko; Timonen, Kirsi L
2017-04-01
Measurement standards for pulmonary diffusing capacity were updated in 2005 by the ATS/ERS Task Force. However, in Finland reference values published in 1982 by Viljanen et al. have been used to date. The main aim of this study was to produce updated reference models for single-breath diffusing capacity for carbon monoxide for Finnish adults. Single-breath diffusing capacity for carbon monoxide was measured in 631 healthy non-smoking volunteers (41.5% male). Reference values for diffusing capacity (DLCO), alveolar volume (VA), diffusing capacity per unit of lung volume (DLCO/VA), and lung volumes were calculated using a linear regression model. Previously used Finnish reference values were found to produce too low predicted values, with mean predicted DLCO 111.0 and 104.4%, and DLCO/VA of 103.5 and 102.7% in males and females, respectively. With the European Coalition for Steel and Coal (ECSC) reference values there was a significant sex difference in DLCO/VA with mean predicted 105.4% in males and 92.8% in females (p < .001). New reference values for DLCO, DLCO/VA, VA, vital capacity (VC), inspiratory vital capacity (IVC), and inspiratory capacity (IC) are suggested for clinical use to replace technically outdated reference values for clinical applications.
Compensated intruder-detection systems
McNeilly, David R.; Miller, William R.
1984-01-01
Intruder-detection systems in which intruder-induced signals are transmitted through a medium also receive spurious signals induced by changes in a climatic condition affecting the medium. To combat this, signals received from the detection medium are converted to a first signal. The system also provides a reference signal proportional to climate-induced changes in the medium. The first signal and the reference signal are combined for generating therefrom an output signal which is insensitive to the climatic changes in the medium. An alarm is energized if the output signal exceeds a preselected value. In one embodiment, an acoustic cable is coupled to a fence to generate a first electrical signal proportional to movements thereof. False alarms resulting from wind-induced movements of the fence (detection medium) are eliminated by providing an anemometer-driven voltage generator to provide a reference voltage proportional to the velocity of wind incident on the fence. An analog divider receives the first electrical signal and the reference signal as its numerator and denominator inputs, respectively, and generates therefrom an output signal which is insensitive to the wind-induced movements in the fence.
Microfabricated fuel heating value monitoring device
Robinson, Alex L [Albuquerque, NM; Manginell, Ronald P [Albuquerque, NM; Moorman, Matthew W [Albuquerque, NM
2010-05-04
A microfabricated fuel heating value monitoring device comprises a microfabricated gas chromatography column in combination with a catalytic microcalorimeter. The microcalorimeter can comprise a reference thermal conductivity sensor to provide diagnostics and surety. Using microfabrication techniques, the device can be manufactured in production quantities at a low per-unit cost. The microfabricated fuel heating value monitoring device enables continuous calorimetric determination of the heating value of natural gas with a 1 minute analysis time and 1.5 minute cycle time using air as a carrier gas. This device has applications in remote natural gas mining stations, pipeline switching and metering stations, turbine generators, and other industrial user sites. For gas pipelines, the device can improve gas quality during transfer and blending, and provide accurate financial accounting. For industrial end users, the device can provide continuous feedback of physical gas properties to improve combustion efficiency during use.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stow, Sarah M.; Causon, Tim J.; Zheng, Xueyun
Collision cross section (CCS) measurements resulting from ion mobility-mass spectrometry (IM-MS) experiments provide a promising orthogonal dimension of structural information in MS-based analytical separations. As with any molecular identifier, interlaboratory standardization must precede broad range integration into analytical workflows. In this study, we present a reference drift tube ion mobility mass spectrometer (DTIM-MS) where improvements on the measurement accuracy of experimental parameters influencing IM separations provide standardized drift tube, nitrogen CCS values (DTCCSN2) for over 120 unique ion species with the lowest measurement uncertainty to date. The reproducibility of these DTCCSN2 values are evaluated across three additional laboratories on amore » commercially available DTIM-MS instrument. The traditional stepped field CCS method performs with a relative standard deviation (RSD) of 0.29% for all ion species across the three additional laboratories. The calibrated single field CCS method, which is compatible with a wide range of chromatographic inlet systems, performs with an average, absolute bias of 0.54% to the standardized stepped field DTCCSN2 values on the reference system. The low RSD and biases observed in this interlaboratory study illustrate the potential of DTIM-MS for providing a molecular identifier for a broad range of discovery based analyses.« less
ERIC Educational Resources Information Center
Marcinkiw, Karen L.
2003-01-01
Culturally competent nurses enable clients to feel respected, valued, and motivated to achieve health goals. A model for nursing education should develop cultural awareness, knowledge, and skills; provide cultural immersion experiences; and foster the desire to work with diverse clients. (Contains 48 references.) (SK)
EURRECA: development of tools to improve the alignment of micronutrient recommendations.
Matthys, C; Bucchini, L; Busstra, M C; Cavelaars, A E J M; Eleftheriou, P; Garcia-Alvarez, A; Fairweather-Tait, S; Gurinović, M; van Ommen, B; Contor, L
2010-11-01
Approaches through which reference values for micronutrients are derived, as well as the reference values themselves, vary considerably across countries. Harmonisation is needed to improve nutrition policy and public health strategies. The EURRECA (EURopean micronutrient RECommendations Aligned, http://www.eurreca.org) Network of Excellence is developing generic tools for systematically establishing and updating micronutrient reference values or recommendations. Different types of instruments (including best practice guidelines, interlinked web pages, online databases and decision trees) have been identified. The first set of instruments is for training purposes and includes mainly interactive digital learning materials. The second set of instruments comprises collection and interlinkage of diverse information sources that have widely varying contents and purposes. In general, these sources are collections of existing information. The purpose of the majority of these information sources is to provide guidance on best practice for use in a wider scientific community or for users and stakeholders of reference values. The third set of instruments includes decision trees and frameworks. The purpose of these tools is to guide non-scientists in decision making based on scientific evidence. This platform of instruments will, in particular in Central and Eastern European countries, contribute to future capacity-building development in nutrition. The use of these tools by the scientific community, the European Food Safety Authority, bodies responsible for setting national nutrient requirements and others should ultimately help to align nutrient-based recommendations across Europe. Therefore, EURRECA can contribute towards nutrition policy development and public health strategies.
Yang, Qian; Lew, Hwee Yeong; Peh, Raymond Hock Huat; Metz, Michael Patrick; Loh, Tze Ping
2016-10-01
Reference intervals are the most commonly used decision support tool when interpreting quantitative laboratory results. They may require partitioning to better describe subpopulations that display significantly different reference values. Partitioning by age is particularly important for the paediatric population since there are marked physiological changes associated with growth and maturation. However, most partitioning methods are either technically complex or require prior knowledge of the underlying physiology/biological variation of the population. There is growing interest in the use of continuous centile curves, which provides seamless laboratory reference values as a child grows, as an alternative to rigidly described fixed reference intervals. However, the mathematical functions that describe these curves can be complex and may not be easily implemented in laboratory information systems. Hence, the use of fixed reference intervals is expected to continue for a foreseeable time. We developed a method that objectively proposes optimised age partitions and reference intervals for quantitative laboratory data (http://research.sph.nus.edu.sg/pp/ppResult.aspx), based on the sum of gradient that best describes the underlying distribution of the continuous centile curves. It is hoped that this method may improve the selection of age intervals for partitioning, which is receiving increasing attention in paediatric laboratory medicine. Copyright © 2016 Royal College of Pathologists of Australasia. Published by Elsevier B.V. All rights reserved.
Statistical considerations for harmonization of the global multicenter study on reference values.
Ichihara, Kiyoshi
2014-05-15
The global multicenter study on reference values coordinated by the Committee on Reference Intervals and Decision Limits (C-RIDL) of the IFCC was launched in December 2011, targeting 45 commonly tested analytes with the following objectives: 1) to derive reference intervals (RIs) country by country using a common protocol, and 2) to explore regionality/ethnicity of reference values by aligning test results among the countries. To achieve these objectives, it is crucial to harmonize 1) the protocol for recruitment and sampling, 2) statistical procedures for deriving the RI, and 3) test results through measurement of a panel of sera in common. For harmonized recruitment, very lenient inclusion/exclusion criteria were adopted in view of differences in interpretation of what constitutes healthiness by different cultures and investigators. This policy may require secondary exclusion of individuals according to the standard of each country at the time of deriving RIs. An iterative optimization procedure, called the latent abnormal values exclusion (LAVE) method, can be applied to automate the process of refining the choice of reference individuals. For global comparison of reference values, test results must be harmonized, based on the among-country, pair-wise linear relationships of test values for the panel. Traceability of reference values can be ensured based on values assigned indirectly to the panel through collaborative measurement of certified reference materials. The validity of the adopted strategies is discussed in this article, based on interim results obtained to date from five countries. Special considerations are made for dissociation of RIs by parametric and nonparametric methods and between-country difference in the effect of body mass index on reference values. Copyright © 2014 Elsevier B.V. All rights reserved.
[Weight and height local growth charts of Algerian children and adolescents (6-18 years of age)].
Bahchachi, N; Dahel-Mekhancha, C C; Rolland-Cachera, M F; Badis, N; Roelants, M; Hauspie, R; Nezzal, L
2016-04-01
Measurements of height and weight provide important information on growth and development, puberty, and nutritional status in children and adolescents. The aim of this study was to develop contemporary reference growth centiles for Algerian children and adolescents (6-18 years of age). A cross-sectional growth survey was conducted in government schools on 7772 healthy schoolchildren (45.1% boys and 54.9% girls) aged 6-18 years in Constantine (eastern Algeria) in 2008. Height and weight were measured with portable stadiometers and calibrated scales, respectively. Smooth reference curves of height and weight were estimated with the LMS method. These height and weight curves are presented together with local data from Arab countries and with the growth references of France, Belgium (Flanders), and the World Health Organization (WHO) 2007. In girls, median height and weight increased until 16 and 17 years of age, respectively, whereas in boys, they increased through age 18 years. Between ages 11 and 13 years (puberty), girls were taller and heavier than boys. After puberty, boys became taller than girls, by up to 13 cm by the age of 18 years. Median height and weight of Algerian boys and girls were generally intermediate between those observed in other Arab countries. They were higher than the French reference values up to the age of 13 years and lower than Belgian and WHO reference values at all ages. The present study provides Algerian height- and weight-for-age growth charts, which should be recommended as a national reference for monitoring growth and development in children and adolescents. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Zikmund-Fisher, Brian J; Scherer, Aaron M; Witteman, Holly O; Solomon, Jacob B; Exe, Nicole L; Fagerlin, Angela
2018-03-26
Patient-facing displays of laboratory test results typically provide patients with one reference point (the "standard range"). To test the effect of including an additional harm anchor reference point in visual displays of laboratory test results, which indicates how far outside of the standard range values would need to be in order to suggest substantial patient risk. Using a demographically diverse, online sample, we compared the reactions of 1618 adults in the United States who viewed visual line displays that included both standard range and harm anchor reference points ("Many doctors are not concerned until here") to displays that included either (1) only a standard range, (2) standard range plus evaluative categories (eg, "borderline high"), or (3) a color gradient showing degree of deviation from the standard range. Providing the harm anchor reference point significantly reduced perceived urgency of close-to-normal alanine aminotransferase and creatinine results (P values <.001) but not generally for platelet count results. Notably, display type did not significantly alter perceptions of more extreme results in potentially harmful ranges. Harm anchors also substantially reduced the number of participants who wanted to contact their doctor urgently or go to the hospital about these test results. Presenting patients with evaluative cues regarding when test results become clinically concerning can reduce the perceived urgency of out-of-range results that do not require immediate clinical action. ©Brian J Zikmund-Fisher, Aaron M Scherer, Holly O Witteman, Jacob B Solomon, Nicole L Exe, Angela Fagerlin. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 26.03.2018.
New NIST sediment SRM for inorganic analysis.
Zeisler, Rolf
2004-03-01
NIST maintains a portfolio of more than 1300 standard reference materials (SRM), more than a third of these relating to measurements in the biological and environmental fields. As part of the continuous renewal and replacement efforts, a set of new marine sediments has been recently developed covering organic and inorganic determinations. This paper describes the steps taken in sample preparation, homogeneity assay, and analytical characterization and certification with specific emphasis on SRM 2702 inorganics in marine sediment. Neutron activation analysis showed the SRM to be highly homogeneous, opening the possibility for use with solid sampling techniques. The certificate provides certified mass fraction values for 25 elements, reference values for eight elements, and information values for 11 elements, covering most of the priority pollutants with small uncertainties of only several percent relative. The values were obtained by combining results from different laboratories and techniques using a Bayesian statistical model. An intercomparison carried out in field laboratories with the material before certification illustrates a high commutability of this SRM.
Khoury, Cheryl; Werry, Kate; Haines, Douglas; Walker, Mike; Malowany, Morie
2018-05-01
The Canadian Health Measures Survey collects nationally representative human biomonitoring data on a suite of chemicals and their metabolites, including many non-persistent chemicals. Data has been collected on non-persistent chemicals, including acrylamide, chlorophenols, environmental phenols and triclocarban, organophosphate insecticides, phthalates, polycyclic aromatic hydrocarbon, pyrethroid insecticides, and volatile organic compounds from 2009 to 2013. Using a systematic approach building on the reference interval concept proposed by the International Federation of Clinical Chemistry and Laboratory Medicine and the International Union of Pure and Applied Chemistry, we derive human biomonitoring reference values (RV 95 s) for these classes of non-persistent chemicals in blood and urine for the general Canadian population. RV 95 s were derived for biomarkers of non-persistent chemicals with widespread detection in Canadians (>66% detection rate). Samples with urinary creatinine levels outside the recommended range of 0.3-3.0 μg/L were excluded. Reference populations were constructed by applying smoking and fasting as exclusion criteria where appropriate. Age and sex were evaluated as possible partitioning criteria and separate RV 95 s were derived for sub-populations in cases where partitioning was deemed necessary. Reference values were derived for 40 biomarkers and represent the first set of RV 95 s for non-persistent chemicals in the general Canadian population. These values provide a measure of the upper margin of background exposure in the general population and can be compared against individual and population human biomonitoring data. RV 95 s can be used to by public health officials to identify individuals with high exposures, and by risk assessors and risk managers to identify atypical exposures or subpopulations with elevated exposures. Crown Copyright © 2018. Published by Elsevier GmbH. All rights reserved.
Monitoring hydrofrac-induced seismicity by surface arrays - the DHM-Project Basel case study
NASA Astrophysics Data System (ADS)
Blascheck, P.; Häge, M.; Joswig, M.
2012-04-01
The method "nanoseismic monitoring" was applied during the hydraulic stimulation at the Deep-Heat-Mining-Project (DHM-Project) Basel. Two small arrays in a distance of 2.1 km and 4.8 km to the borehole recorded continuously for two days. During this time more than 2500 seismic events were detected. The method of the surface monitoring of induced seismicity was compared to the reference which the hydrofrac monitoring presented. The latter was conducted by a network of borehole seismometers by Geothermal Explorers Limited. Array processing provides a outlier resistant, graphical jack-knifing localization method which resulted in a average deviation towards the reference of 850 m. Additionally, by applying the relative localization master-event method, the NNW-SSE strike direction of the reference was confirmed. It was shown that, in order to successfully estimate the magnitude of completeness as well as the b-value at the event rate and detection sensibility present, 3 h segments of data are sufficient. This is supported by two segment out of over 13 h of evaluated data. These segments were chosen so that they represent a time during the high seismic noise during normal working hours in daytime as well as the minimum anthropogenic noise at night. The low signal-to-noise ratio was compensated by the application of a sonogram event detection as well as a coincidence analysis within each array. Sonograms allow by autoadaptive, non-linear filtering to enhance signals whose amplitudes are just above noise level. For these events the magnitude was determined by the master-event method, allowing to compute the magnitude of completeness by the entire-magnitude-range method provided by the ZMAP toolbox. Additionally, the b-values were determined and compared to the reference values. An introduction to the method of "nanoseismic monitoring" will be given as well as the comparison to reference data in the Basel case study.
Reference-free direct digital lock-in method and apparatus
NASA Technical Reports Server (NTRS)
Henry, James E. (Inventor); Leonard, John A. (Inventor)
2000-01-01
A reference-free direct digital lock-in system (RDDL 10) has a first input coupled to a periodic electrical signal and an output for outputting an indication of a magnitude of a desired periodic signal component. The RDDL also has a second input for receiving a signal (9) that specifies a reference period value, and operates to autonomously generate a lock-in reference signal having a specified period and a phase that is adjusted to maximize a magnitude of the outputted desired periodic signal component. In an embodiment of a measurement system that includes the RDDL 10 an optical source provides a chopped light beam having wavelengths within a predetermined range of wavelengths, and the periodic electrical signal is generated by at least one photodetector that is illuminated by the chopped light beam. In this embodiment the measurement system characterizes, for at least one wavelength of light that is generated by the optical source, a spectral response of the at least one photodetector. The RDDL can operate in nonreal-time upon previously generated and stored digital equivalent values of the periodic electrical signal or signals.
Reliability of reference distances used in photogrammetry.
Aksu, Muge; Kaya, Demet; Kocadereli, Ilken
2010-07-01
To determine the reliability of the reference distances used for photogrammetric assessment. The sample consisted of 100 subjects with mean ages of 22.97 +/- 2.98 years. Five lateral and four frontal parameters were measured directly on the subjects' faces. For photogrammetric assessment, two reference distances for the profile view and three reference distances for the frontal view were established. Standardized photographs were taken and all the parameters that had been measured directly on the face were measured on the photographs. The reliability of the reference distances was checked by comparing direct and indirect values of the parameters obtained from the subjects' faces and photographs. Repeated measure analysis of variance (ANOVA) and Bland-Altman analyses were used for statistical assessment. For profile measurements, the indirect values measured were statistically different from the direct values except for Sn-Sto in male subjects and Prn-Sn and Sn-Sto in female subjects. The indirect values of Prn-Sn and Sn-Sto were reliable in both sexes. The poorest results were obtained in the indirect values of the N-Sn parameter for female subjects and the Sn-Me parameter for male subjects according to the Sa-Sba reference distance. For frontal measurements, the indirect values were statistically different from the direct values in both sexes except for one in male subjects. The indirect values measured were not statistically different from the direct values for Go-Go. The indirect values of Ch-Ch were reliable in male subjects. The poorest results were obtained according to the P-P reference distance. For profile assessment, the T-Ex reference distance was reliable for Prn-Sn and Sn-Sto in both sexes. For frontal assessment, Ex-Ex and En-En reference distances were reliable for Ch-Ch in male subjects.
Tolosa, Imma; Cassi, Roberto; Huertas, David
2018-04-11
A new marine sediment certified reference material (IAEA 459) with very low concentrations (μg kg -1 ) for a variety of persistent organic contaminants (POPs) listed by the Stockholm Convention, as well as other POPs and priority substances (PSs) listed in many environmental monitoring programs was developed by the IAEA. The sediment material was collected from the Ham River estuary in South Korea, and the assigned final values were derived from robust statistics on the results provided by selected laboratories which demonstrated technical and quality competence, following the guidance given in ISO Guide 35. The robust mean of the laboratory means was assigned as certified values, for those compounds where the assigned value was derived from at least five datasets and its relative expanded uncertainty was less than 40% of the assigned value (most of the values ranging from 8 to 20%). All the datasets were derived from at least two different analytical techniques which have allowed the assignment of certified concentrations for 22 polychlorinated biphenyl (PCB) congeners, 6 organochlorinated (OC) pesticides, 5 polybrominated diphenyl ethers (PBDEs), and 18 polycyclic aromatic hydrocarbon (PAHs). Mass fractions of compounds that did not fulfill the criteria of certification are considered information values, which include 29 PAHs, 11 PCBs, 16 OC pesticides, and 5 PBDEs. The extensive characterization and associated uncertainties at concentration levels close to the marine sediment quality guidelines will make CRM 459 a valuable matrix reference material for use in marine environmental monitoring programs.
The Study and Measurement of Values and Attitudes.
ERIC Educational Resources Information Center
Kerlinger, Fred N.
The author defines values, attitudes, and beliefs according to their relation to referents. A referent is a construct standing for a set or category of social objects, ideas, or behaviors that is the focus of an attitude. Attitudes and values are belief systems. Beliefs are enduring cognitions about referents; beliefs reflect the value and…
USDA-ARS?s Scientific Manuscript database
Nutrient reference values have significant public health and policy implications. Given the importance of defining reliable nutrient reference values, there is a need for an explicit, objective, and transparent process to set these values. The Tufts Medical Center Evidence-based Practice Center asse...
Bedewi, Mohamed Abdelmohsen; Abodonya, Ahmed; Kotb, Mamdouh; Kamal, Sanaa; Mahmoud, Gehan; Aldossari, Khaled; Alqabbani, Abdullah; Swify, Sherine
2018-03-01
The objective of this study is to estimate the reference values for the lower limb peripheral nerves in adults.The demographics and physical characteristics of 69 adult healthy volunteers were evaluated and recorded. The estimated reference values and their correlations with the age, weight, height, body mass index (BMI) were evaluated.The cross sectional area reference values were obtained at 5 predetermined sites for 3 important lower limb peripheral nerves. Our CSA values correlated significantly with age, weight, and BMI. The normal reference values for each nerve were as follows: Tibial nerve at the popliteal fossa 19 mm ± 6.9, tibial nerve at the level of the medial malleolus 12.7 mm ± 4.5, common peroneal nerve at the popliteal fossa 9.5 mm ± 4, common peroneal nerve fibular head 8.9 mm ± 3.2, sural nerve 3.5 mm ± 1.4.The reference values for the lower limb peripheral nerves were identified. These values could be used for future management of peripheral nerve disorders.
Ackerly, D D; Cornwell, W K
2007-02-01
Plant functional traits vary both along environmental gradients and among species occupying similar conditions, creating a challenge for the synthesis of functional and community ecology. We present a trait-based approach that provides an additive decomposition of species' trait values into alpha and beta components: beta values refer to a species' position along a gradient defined by community-level mean trait values; alpha values are the difference between a species' trait values and the mean of co-occurring taxa. In woody plant communities of coastal California, beta trait values for specific leaf area, leaf size, wood density and maximum height all covary strongly, reflecting species distributions across a gradient of soil moisture availability. Alpha values, on the other hand, are generally not significantly correlated, suggesting several independent axes of differentiation within communities. This trait-based framework provides a novel approach to integrate functional ecology and gradient analysis with community ecology and coexistence theory.
Serum proteins by capillary zone electrophoresis: approaches to the definition of reference values.
Petrini, C; Alessio, M G; Scapellato, L; Brambilla, S; Franzini, C
1999-10-01
The Paragon CZE 2000 (Beckman Analytical, Milan, Italy) is an automatic dedicated capillary zone electrophoresis (CZE) system, producing a five-zone serum protein pattern with quantitative estimation of the zones. With the view of substituting this instrument for two previously used serum protein electrophoresis techniques, we planned to produce reference values for the "new" systems leading to compatible interpretation of the results. High resolution cellulose acetate electrophoresis with visual inspection and descriptive reporting (HR-CAE) and five-zone cellulose acetate electrophoresis with densitometry (CAE-D) were the previously used techniques. Serum samples (n = 167) giving "normal pattern" with HR-CAE were assayed with the CZE system, and the results were statistically assessed to yield 0.95 reference intervals. One thousand normal and pathological serum samples were then assayed with the CAE-D and the CZE techniques, and the regression equations of the CAE-D values over the CZE values for the five zones were used to transform the CAE-D reference limits into the CZE reference limits. The two sets of reference values thereby produced were in good agreement with each other and also with reference values previously reported for the CZE system. Thus, reference values for the CZE techniques permit interpretation of results coherent with the previously used techniques and reporting modes.
Perri, Amanda M.; O’Sullivan, Terri L.; Harding, John C.S.; Wood, R. Darren; Friendship, Robert M.
2017-01-01
The evaluation of pig hematology and biochemistry parameters is rarely done largely due to the costs associated with laboratory testing and labor, and the limited availability of reference intervals needed for interpretation. Within-herd and between-herd biological variation of these values also make it difficult to establish reference intervals. Regardless, baseline reference intervals are important to aid veterinarians in the interpretation of blood parameters for the diagnosis and treatment of diseased swine. The objective of this research was to provide reference intervals for hematology and biochemistry parameters of 3-week-old commercial nursing piglets in Ontario. A total of 1032 pigs lacking clinical signs of disease from 20 swine farms were sampled for hematology and iron panel evaluation, with biochemistry analysis performed on a subset of 189 randomly selected pigs. The 95% reference interval, mean, median, range, and 90% confidence intervals were calculated for each parameter. PMID:28373729
No-reference multiscale blur detection tool for content based image retrieval
NASA Astrophysics Data System (ADS)
Ezekiel, Soundararajan; Stocker, Russell; Harrity, Kyle; Alford, Mark; Ferris, David; Blasch, Erik; Gorniak, Mark
2014-06-01
In recent years, digital cameras have been widely used for image capturing. These devices are equipped in cell phones, laptops, tablets, webcams, etc. Image quality is an important component of digital image analysis. To assess image quality for these mobile products, a standard image is required as a reference image. In this case, Root Mean Square Error and Peak Signal to Noise Ratio can be used to measure the quality of the images. However, these methods are not possible if there is no reference image. In our approach, a discrete-wavelet transformation is applied to the blurred image, which decomposes into the approximate image and three detail sub-images, namely horizontal, vertical, and diagonal images. We then focus on noise-measuring the detail images and blur-measuring the approximate image to assess the image quality. We then compute noise mean and noise ratio from the detail images, and blur mean and blur ratio from the approximate image. The Multi-scale Blur Detection (MBD) metric provides both an assessment of the noise and blur content. These values are weighted based on a linear regression against full-reference y values. From these statistics, we can compare to normal useful image statistics for image quality without needing a reference image. We then test the validity of our obtained weights by R2 analysis as well as using them to estimate image quality of an image with a known quality measure. The result shows that our method provides acceptable results for images containing low to mid noise levels and blur content.
Energy Index For Aircraft Maneuvers
NASA Technical Reports Server (NTRS)
Chidester, Thomas R. (Inventor); Lynch, Robert E. (Inventor); Lawrence, Robert E. (Inventor); Amidan, Brett G. (Inventor); Ferryman, Thomas A. (Inventor); Drew, Douglas A. (Inventor); Ainsworth, Robert J. (Inventor); Prothero, Gary L. (Inventor); Romanowski, Tomothy P. (Inventor); Bloch, Laurent (Inventor)
2006-01-01
Method and system for analyzing, separately or in combination, kinetic energy and potential energy and/or their time derivatives, measured or estimated or computed, for an aircraft in approach phase or in takeoff phase, to determine if the aircraft is or will be put in an anomalous configuration in order to join a stable approach path or takeoff path. A 3 reference value of kinetic energy andor potential energy (or time derivatives thereof) is provided, and a comparison index .for the estimated energy and reference energy is computed and compared with a normal range of index values for a corresponding aircraft maneuver. If the computed energy index lies outside the normal index range, this phase of the aircraft is identified as anomalous, non-normal or potentially unstable.
System and methods for reducing harmonic distortion in electrical converters
Kajouke, Lateef A; Perisic, Milun; Ransom, Ray M
2013-12-03
Systems and methods are provided for delivering energy using an energy conversion module. An exemplary method for delivering energy from an input interface to an output interface using an energy converison module coupled between the input interface and the output interface comprises the steps of determining an input voltage reference for the input interface based on a desired output voltage and a measured voltage and the output interface, determining a duty cycle control value based on a ratio of the input voltage reference and the measured voltage, operating one or more switching elements of the energy conversion module to deliver energy from the input interface to the output interface to the output interface with a duty cycle influenced by the dute cycle control value.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McDaniel, E.W.; Flannery, M.R.; Thomas, E.W.
This bibliography deals mainly with binary and ternary collisions involving electrons, photons, and heavy particles (i.e., atoms, molecules, and ions). The energy range covered for each kind of collision is such that the interactions might be described as electronic, atomic, or chemical--higher-energy collisions involving nuclear forces are not treated. Also covered are particle and photon impact on surfaces, the passage of particles and radiation through bulk matter, and transport phenomena in gases. Practically all of the references cited are data compilations, other bibliographies, review articles, or books. The main objective is to provide easy access to atomic collision data, althoughmore » some references are included principally for their tutorial value.« less
Bel Hadj Hmida, Y; Tahri, N; Sellami, A; Yangui, N; Jlidi, R; Beyrouti, M I; Krichen, M S; Masmoudi, H
2001-01-01
In order to determine the sensitivity of CEA in the diagnosis of colo-rectal carcinoma, we studied a series of 48 patients with colo-rectal carcinoma (1992-1996). The sensitivity was at 52% with a reference value of 5 ng/ml and 68.7% for a reference value of 2.5 ng/ml. With a reference value of 5 ng/ml, the sensitivity of CEA was at 37% only for patients with colo-rectal carcinoma at Dukes B stage, 66.6% for patients at stage C and 75% for patients at stage D. The dosage of CEA was carried out with a sandwich immunoenzymatic technique in tube. There is no statistic significant correlation between the pre-operative rate of CEA and the localisation of the tumor and its histologic type; in contrast, it was significantly correlated with the ganglionnary metastasis. A significant relationship between the pre-operative rate of CEA and the Dukes stage was found for a reference value of 10 ng/ml but not for a reference value of 5 ng/ml. We calculated the specificity of the CEA for the cancers of colon and rectum which was at 76.98% with a reference value of 5 ng/ml and 86% with a reference value of 10 ng/ml.
Serum free light chain reference values: a critical approach.
Altinier, Sara; Seguso, Mara; Zaninotto, Martina; Varagnolo, Mariacristina; Adami, Fausto; Angeli, Paolo; Plebani, Mario
2013-05-01
The clinical usefulness of serum free light chain (FLC) measurement in the management of patients with plasma cell proliferative disorders has been reported in several papers, and most clinical studies use the reference ranges declared by the manufacturer. The aim of the present study was to evaluate the reproducibility of FLCs immunoassay and to validate the reference range, before introducing it in routine setting. Internal quality control materials and a pool of fresh serum samples were used to evaluate imprecision; 162 fresh sera from healthy blood donors were analyzed to evaluate the reference range for FLCs. In order to verify the κ/λ FLC ratio, 43 sera from patients with polyclonal hypergammaglobulinemia were tested. The FLC immunoassay was performed using a nephelometer with the Freelite reagents. The imprecision studies performed using a serum pool tested with two different lots of reagents showed a mean CV of 16.09% for κFLC and of 16.72% for λFLC. Lower CV%s and different mean values were found by calculating the results from each specific lot separately, while different results were obtained using the control materials provided by the manufacturer. In reference subjects, the 2.5-97.5th percentiles were found to be 4.52-22.33 and 4.84-21.88mg/L for κFLC and λFLC, respectively. The range for κ/λ ratio (0.65-2.36) was validated with the values obtained from subjects with polyclonal hypergammaglobulinemia. In retesting 15 samples from blood donor subjects with a different lot of reagents, mean bias percentages of 17.60 for κFLC and 15.26 for λFLC were obtained. These findings confirm the lot-to-lot variability of the FLC assays also in the measurement of polyclonal light chains, as well as the need to carefully validate the reference values. Published by Elsevier Inc.
Mathis, Michael R.; Schechtman, Samuel A.; Engoren, Milo C.; Shanks, Amy M.; Thompson, Aleda; Kheterpal, Sachin; Tremper, Kevin K.
2016-01-01
Background Assessment of need for intravascular volume resuscitation remains challenging for anesthesiologists. Dynamic waveform indices, including systolic- and pulse-pressure variation (SPV/PPV), are demonstrated as reliable measures of fluid-responsiveness for mechanically ventilated patients. Despite widespread use, real-world reference distributions for SPV and PPV values have not been established for euvolemic intraoperative patients. The authors sought to establish SPV and PPV reference distributions and assess impact of modifying factors. Methods The authors evaluated adult patients undergoing general anesthetics for elective non-cardiac surgery. Median SPV and PPV over a 50-minute post-induction period were noted for each case. Modifying factors including body-mass index, age, ventilator settings, positioning, and hemodynamic management were studied via univariate and multivariable analyses. For SPV values, effects of data entry method (manually-entered versus automated recorded) were similarly studied. Results Among 1,791 cases, per-case median SPV and PPV values formed non-parametric distributions. For each distribution, median values, interquartile ranges, and reference intervals (2.5th-97.5th percentile) were respectively noted: these included manually-entered SPV (6.0, 5.0-7.0, 3.0-11.0 mmHg), automated SPV (4.7, 3.9-6.0, 2.2-10.4 mmHg), and automated PPV (7.0, 5.0-9.0, 2.0-16.0%). Non-supine positioning and preoperative beta blocker were independently associated with altered SPV and PPV, whereas ventilator tidal volume >8 mL/kg ideal body weight and peak inspiratory pressure >16 cm H2O demonstrated independent associations for SPV only. Conclusions This study establishes real-world SPV and PPV reference distributions absent in the current literature. Through a consideration of reference distributions and modifying factors, our study provides further evidence for assessing intraoperative volume status and fluid management therapies. PMID:27906705
Markers of Renal Function and Injury
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ragan, Harvey A.; Weller, Richard E.
1999-04-15
Designed to aid the laboratory animal veterinarian, researcher, or toxicologist in the proper evaluation of organ function, this updated and revised edition provides the only comprehensive reference of the clinical chemistry of laboratory animals. With contributions from recognized experts in the field, new chapters are included that focus on the pig and the ferret, while many chapters have been rewritten. Expanded coverage was given to urine chemistry, hormones, including melatonin, and the control mechanisms of analytes. Reference values are given in both conventional and S.I. units.
Pilot study on peptide purity—synthetic human C-peptide
NASA Astrophysics Data System (ADS)
Josephs, R. D.; Li, M.; Song, D.; Daireaux, A.; Choteau, T.; Stoppacher, N.; Westwood, S.; Wielgosz, R.; Xiao, P.; Liu, Y.; Gao, X.; Zhang, C.; Zhang, T.; Mi, W.; Quan, C.; Huang, T.; Li, H.; Melanson, J. E.; Ün, I.; Gören, A. C.; Quaglia, M.; Warren, J.
2017-01-01
Under the auspices of the Protein Analysis Working Group (PAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a pilot study, CCQM-P55.2, was coordinated by the Bureau International des Poids et Mesures (BIPM) and the Chinese National Institute of Metrology (NIM). Four Metrology Institutes or Designated Institutes and the BIPM participated. Participants were required to assign the mass fraction of human C-peptide (hCP) present as the main component in the comparison sample for CCQM-P55.2. The comparison samples were prepared from synthetic human hCP purchased from a commercial supplier and used as provided without further treatment or purification. hCP was selected to be representative of the performance of a laboratory's measurement capability for the purity assignment of short (up to 5 kDa), non-cross-linked synthetic peptides/proteins. It was anticipated to provide an analytical measurement challenge representative for the value-assignment of compounds of broadly similar structural characteristics. The majority of participants used a quantitative nuclear magnetic resonance spectroscopy (qNMR) corrected for peptide impurities. Other participants provided results obtained by peptide impurity corrected amino acid analysis (PICAA) or elemental analysis (PICCHN). It was decided to assign reference values based on the KCRVs of CCQM-K115 for both the hCP mass fraction and the mass fraction of the peptide related impurities as indispensable contributor regardless of the use of PICAA, mass balance or any other approach to determine the hCP purity. This allowed participants to demonstrate the efficacy of their implementation of the approaches used to determine the hCP mass fraction. In particular it allows participants to demonstrate the efficacy of their implementation of peptide related impurity identification and quantification. The assessment of the mass fraction of peptide impurities is based on the assumption that only the most exhaustive and elaborate set of results is taken for the calculation of the reference value. The reference value for the peptide related impurity mass fractions of the material was 83.3 mg/g with a combined standard uncertainty of 1.5 mg/g. Inspection of the degree of equivalence plots for the mass fraction of peptide impurities and additional information obtained from the peptide related impurity profile indicates that in many cases only a very small number of impurities have been identified and quantified resulting in an underestimation of the peptide related impurity mass fractions. The reference value for the mass fraction of hCP for CCQM-KP55.2 is 801.8 mg/g with a corresponding combined standard uncertainty of 3.1 mg/g. Inspection of the degree of equivalence plots for CCQM-P55.2 for the mass fraction of hCP shows that three results agree with the reference value. Main text To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM.
Testosterone Trajectories and Reference Ranges in a Large Longitudinal Sample of Male Adolescents
Khairullah, Ammar; Cousino Klein, Laura; Ingle, Suzanne M.; May, Margaret T.; Whetzel, Courtney A.; Susman, Elizabeth J.; Paus, Tomáš
2014-01-01
Purpose Pubertal dynamics plays an important role in physical and psychological development of children and adolescents. We aim to provide reference ranges of plasma testosterone in a large longitudinal sample. Furthermore, we describe a measure of testosterone trajectories during adolescence that can be used in future investigations of development. Methods We carried out longitudinal measurements of plasma testosterone in 2,216 samples obtained from 513 males (9 to 17 years of age) from the Avon Longitudinal Study of Parents and Children. We used integration of a model fitted to each participant’s testosterone trajectory to calculate a measure of average exposure to testosterone over adolescence. We pooled these data with corresponding values reported in the literature to provide a reference range of testosterone levels in males between the ages of 6 and 19 years. Results The average values of total testosterone in the ALSPAC sample range from 0.82 nmol/L (Standard Deviation [SD]: 0.09) at 9 years of age to 16.5 (SD: 2.65) nmol/L at 17 years of age; these values are congruent with other reports in the literature. The average exposure to testosterone is associated with different features of testosterone trajectories such as Peak Testosterone Change, Age at Peak Testosterone Change, and Testosterone at 17 years of age as well as the timing of the growth spurt during puberty. Conclusions The average exposure to testosterone is a useful measure for future investigations using testosterone trajectories to examine pubertal dynamics. PMID:25268961
[Analysis of generic drug supply in France].
Taboulet, F; Haramburu, F; Latry, Ph
2003-09-01
The list of generic medicines (LGM), published since 1997 by the Agence Française de Sécurité Sanitaire des Produits de Santé (AFFSSaPS), the French Medicine Agency, concerns a special part of the medicines reimbursed by the National Health Insurance (Social Security). The objectives of the present study were: i) to describe the components of this list, based on pharmaceutical, economical and therapeutic characteristics, ii) to study differences between generic and reference products (formulations, excipients, prices, etc.), iii) to analyze information on excipients provided to health care professionals. The 21st version of the LGM (April 2001) was used. Therapeutic value was retrieved from the 2001 AFSSaPS report on the therapeutic value of 4490 reimbursed medicines. Information on excipients in the LGM and the Vidal dictionary (reference prescription book in France) was compared. The products included in the LGM represent 20% of all reimbursed medicines. The mean price differences between generics and their reference products vary between 30 and 50% for more than two thirds of the generic groups. The therapeutic value of the products of the LGM was judged important in 71% of cases (vs 63% for the 4409 assessed medicines) and insufficient in 13% of cases (vs 19%). Information on excipients is often missing and sometimes erroneous. Although the LGM is regularly revised and thus the generic market in perpetual change, the 2001 cross description of this pharmaceutical market provides much informations and raises some concern.
Lung Reference Set A Application: LaszloTakacs - Biosystems (2010) — EDRN Public Portal
We would like to access the NCI lung cancer Combined Pre-Validation Reference Set A in order to further validate a lung cancer diagnostic test candidate. Our test is based on a panel of antibodies which have been tested on 4 different cohorts (see below, paragraph “Preliminary Data and Methods”). This Reference Set A, whose clinical setting is “Diagnosis of lung cancer”, will be used to validate the panel of monoclonal antibodies which have been demonstrated by extensive data analysis to provide the best discrimination between controls and Lung Cancer patient plasma samples, sensitivity and specificity values from ROC analyses are superior than 85 %.
[The reference of normal values of the sacroiliac joint index in bone scintigraphy].
Sebastjanowicz, Przemysław; Iwanowski, Jacek; Piwowarska-Bilska, Hanna; Elbl, Bogumiła; Birkenfeld, Bożena
Scintigraphy of sacroiliac joints as functional imaging provides unique information on the existing disease process. By using radiopharmaceuticals that allow imaging of the metabolic activity within the joint, it is possible to assess the stage of the disease, even when there are no lesions in radiological images. Quantitative analysis of scintigrams of sacroiliac joints is performed by comparing the uptake in both of them in relation to the uptake in the sacral bone area. The values of sacroiliac (SI/S) indices are influenced by the age of the patient, sex, state of health, and a range of individual biological features. Therefore, reference values of SI/S ratios are very important for medical specialists who describe and diagnose locomotor system diseases. The aim of this paper is to develop a reference range of sacroiliac ratios. The innovativeness of this paper involves examining sacroiliac ratios for various age groups, in children and adult patients, taking their sex into consideration. The study comprised a group of 335 people with proper bone scintigraphy. These people were divided into children and patients aged ≥21. Children were divided into 4 age groups (1–5; 6–10; 11–15; 16–20) and adults into 6 age groups (21–30; 31–40; 41–50; 51–60; 61–70; ≥71). Sacroiliac ratios were calculated using the method of three rectangular region of interests located on the left and right sacroiliac joint and on the sacral bone. The sacroiliac ratio was calculated for both joints by dividing the average number of counts within a selected sacroiliac joint by the average number of counts within the sacral bone. SI/S borderline reference values covered the range of 1.18÷2.28 that was obtained for children aged ≤5 and for the group of 11–15-year-olds. Considerable discrepancies in the values of the coefficient for women and men were seen among 31–50-year-olds. Borderline reference results for the entire control group cover the range of 1.18 ±2.28. The lower reference value applies to ≤5-year-olds, whereas the higher value applies to the group of 11–15-year-olds. The standard deviation value obtained was highest in paediatric patients. The results indicate the occurrence of significant individual differences between patients in this age group.
Christiansen, Mark P; Klaff, Leslie J; Brazg, Ronald; Chang, Anna R; Levy, Carol J; Lam, David; Denham, Douglas S; Atiee, George; Bode, Bruce W; Walters, Steven J; Kelley, Lynne; Bailey, Timothy S
2018-03-01
Persistent use of real-time continuous glucose monitoring (CGM) improves diabetes control in individuals with type 1 diabetes (T1D) and type 2 diabetes (T2D). PRECISE II was a nonrandomized, blinded, prospective, single-arm, multicenter study that evaluated the accuracy and safety of the implantable Eversense CGM system among adult participants with T1D and T2D (NCT02647905). The primary endpoint was the mean absolute relative difference (MARD) between paired Eversense and Yellow Springs Instrument (YSI) reference measurements through 90 days postinsertion for reference glucose values from 40 to 400 mg/dL. Additional endpoints included Clarke Error Grid analysis and sensor longevity. The primary safety endpoint was the incidence of device-related or sensor insertion/removal procedure-related serious adverse events (SAEs) through 90 days postinsertion. Ninety participants received the CGM system. The overall MARD value against reference glucose values was 8.8% (95% confidence interval: 8.1%-9.3%), which was significantly lower than the prespecified 20% performance goal for accuracy (P < 0.0001). Ninety-three percent of CGM values were within 20/20% of reference values over the total glucose range of 40-400 mg/dL. Clarke Error Grid analysis showed 99.3% of samples in the clinically acceptable error zones A (92.8%) and B (6.5%). Ninety-one percent of sensors were functional through day 90. One related SAE (1.1%) occurred during the study for removal of a sensor. The PRECISE II trial demonstrated that the Eversense CGM system provided accurate glucose readings through the intended 90-day sensor life with a favorable safety profile.
[Analysis of the body composition of Spanish women with fibromyalgia].
Aparicio, Virginia A; Ortega, Francisco B; Heredia, José M; Carbonell-Baeza, Ana; Delgado-Fernández, Manuel
2011-01-01
To describe the anthropometric profile and body composition of women from Southern Spain diagnosed with fibromyalgia (FM) and to compare the observed values with values from other studies conducted on FM patients and with national reference values. The body composition of 104 women diagnosed with FM was assessed using an eight-electrode impedance meter. The reliability of the body composition measurement was tested in a randomly selected sub-sample (n=28). The reliability study showed a test-retest systematic error close to zero in most of the parameters studied. The women with FM who were studied had a mean weight of 71.3±13.4 kg, height of 158±6 cm, body mass index of 28.6±5.1 kg/m(2), body fat mass of 38.6±7.6%, total body water of 31.6±3.8 l and muscle mass of 23.4±3.0 kg. In general, there were no substantial differences in weight and body mass index between women with FM and those analyzed in other Spanish and European studies involving FM patients, nor when they were compared with regional or national reference values. However, the prevalence of obesity in the women with FM under study was 33.7%, a higher figure than that from the national reference data for obesity in similarly aged women (i.e. 26,4%). The results suggest that obesity is a common condition in women diagnosed with FM, its prevalence in this population being higher than the national reference values. This study provides detailed information about the body composition characteristics of women with FM. Copyright © 2010 Elsevier España, S.L. All rights reserved.
Photosynthesis-related quantities for education and modeling.
Antal, Taras K; Kovalenko, Ilya B; Rubin, Andrew B; Tyystjärvi, Esa
2013-11-01
A quantitative understanding of the photosynthetic machinery depends largely on quantities, such as concentrations, sizes, absorption wavelengths, redox potentials, and rate constants. The present contribution is a collection of numbers and quantities related mainly to photosynthesis in higher plants. All numbers are taken directly from a literature or database source and the corresponding reference is provided. The numerical values, presented in this paper, provide ranges of values, obtained in specific experiments for specific organisms. However, the presented numbers can be useful for understanding the principles of structure and function of photosynthetic machinery and for guidance of future research.
Choice of Reference Serum Creatinine in Defining Acute Kidney Injury.
Siew, Edward D; Matheny, Michael E
2015-01-01
The study of acute kidney injury (AKI) has expanded with the increasing availability of electronic health records and the use of standardized definitions. Understanding the impact of AKI between settings is limited by heterogeneity in the selection of reference creatinine to anchor the definition of AKI. In this mini-review, we discuss different approaches used to select reference creatinine and their relative merits and limitations. We reviewed the literature to obtain representative examples of published baseline creatinine definitions when pre-hospital data were not available, as well as literature evaluating the estimation of baseline renal function, using PubMed and reference back-tracing within known works. (1) Pre-hospital creatinine values are useful in determining reference creatinine, and in high-risk populations, the mean outpatient serum creatinine value 7-365 days before hospitalization closely approximates nephrology adjudication, (2) in patients without pre-hospital data, the eGFR 75 approach does not reliably estimate true AKI incidence in most at-risk populations, (3) using the lowest inpatient serum creatinine may be reasonable, especially in those with preserved kidney function, but may generously estimate AKI incidence and severity and miss community-acquired AKI that does not fully resolve, (4) using more specific definitions of AKI (e.g., KIDGO stages 2 and 3) may help to reduce the effects of misclassification when using surrogate values and (5) leveraging available clinical data may help refine the estimate of reference creatinine. Choosing reference creatinine for AKI calculation is important for AKI classification and study interpretation. We recommend obtaining data on pre-hospital kidney function, wherever possible. In studies where surrogate estimates are used, transparency in how they are applied and discussion that informs the reader of potential biases should be provided. Further work to refine the estimation of reference creatinine is needed. © 2015 S. Karger AG, Basel.
ERIC Educational Resources Information Center
May, Jill P.
1982-01-01
Discusses the criteria for analysis of excellence in children's films and factors involved in the production of a good film, and offers an analysis of three children's films: "The Bridge of Adam Rush,""Angel and Big Joe," and "A Pretty Kettle of Fish." Three references are provided. (EJS)
Verification of ARES transport code system with TAKEDA benchmarks
NASA Astrophysics Data System (ADS)
Zhang, Liang; Zhang, Bin; Zhang, Penghe; Chen, Mengteng; Zhao, Jingchang; Zhang, Shun; Chen, Yixue
2015-10-01
Neutron transport modeling and simulation are central to many areas of nuclear technology, including reactor core analysis, radiation shielding and radiation detection. In this paper the series of TAKEDA benchmarks are modeled to verify the critical calculation capability of ARES, a discrete ordinates neutral particle transport code system. SALOME platform is coupled with ARES to provide geometry modeling and mesh generation function. The Koch-Baker-Alcouffe parallel sweep algorithm is applied to accelerate the traditional transport calculation process. The results show that the eigenvalues calculated by ARES are in excellent agreement with the reference values presented in NEACRP-L-330, with a difference less than 30 pcm except for the first case of model 3. Additionally, ARES provides accurate fluxes distribution compared to reference values, with a deviation less than 2% for region-averaged fluxes in all cases. All of these confirms the feasibility of ARES-SALOME coupling and demonstrate that ARES has a good performance in critical calculation.
Soy foods have low glycemic and insulin response indices in normal weight subjects.
Blair, Robert M; Henley, E C; Tabor, Aaron
2006-12-27
Foods with a low glycemic index (GI) may provide a variety of health benefits. The objective of the present study was to measure the GI and insulin index (II) of select soy foods. The study was conducted in two parts with low-carbohydrate products being tested separately. In Experiment 1, subjects averaged 23.2 years of age with BMI = 22.0 kg/m2, while subjects in Experiment 2 averaged 23.9 years of age with BMI = 21.6 kg/m2. The reference (glucose) and test foods were served in portions containing 10 g of carbohydrates in Experiment 1 (two test foods) and 25 g of carbohydrates in Experiment 2 (four test foods). Subjects consumed the reference food twice and each test food once. For each test, subjects were instructed to consume a fixed portion of the reference food or test food together with 250 g of water within 12 min. Blood samples were collected before each test and at 15, 30, 45, 60, 90, and 120 min after consumption of reference or test foods to quantify glucose and insulin. Two-hour blood glucose and plasma insulin curves were constructed and areas under the curves were calculated. GI and II values for each subject and test food were calculated. In Experiment 1, both low-carbohydrate soy foods were shown to have significantly (P < 0.05) lower GI and II values than the reference food. In Experiment 2, three of the four test foods had significantly (P < 0.05) lower GI and II values than the reference food. All but one of the soy foods tested had a low GI, suggesting that soy foods may be an appropriate part of diets intended to improve control of blood glucose and insulin levels.
Soy foods have low glycemic and insulin response indices in normal weight subjects
2006-01-01
Background Foods with a low glycemic index (GI) may provide a variety of health benefits. The objective of the present study was to measure the GI and insulin index (II) of select soy foods. Methods The study was conducted in two parts with low-carbohydrate products being tested separately. In Experiment 1, subjects averaged 23.2 years of age with BMI = 22.0 kg/m2, while subjects in Experiment 2 averaged 23.9 years of age with BMI = 21.6 kg/m2. The reference (glucose) and test foods were served in portions containing 10 g of carbohydrates in Experiment 1 (two test foods) and 25 g of carbohydrates in Experiment 2 (four test foods). Subjects consumed the reference food twice and each test food once. For each test, subjects were instructed to consume a fixed portion of the reference food or test food together with 250 g of water within 12 min. Blood samples were collected before each test and at 15, 30, 45, 60, 90, and 120 min after consumption of reference or test foods to quantify glucose and insulin. Two-hour blood glucose and plasma insulin curves were constructed and areas under the curves were calculated. GI and II values for each subject and test food were calculated. Results In Experiment 1, both low-carbohydrate soy foods were shown to have significantly (P < 0.05) lower GI and II values than the reference food. In Experiment 2, three of the four test foods had significantly (P < 0.05) lower GI and II values than the reference food. Conclusion All but one of the soy foods tested had a low GI, suggesting that soy foods may be an appropriate part of diets intended to improve control of blood glucose and insulin levels. PMID:17192192
Trujillo, Logan T.; Stanfield, Candice T.; Vela, Ruben D.
2017-01-01
Converging evidence suggests that human cognition and behavior emerge from functional brain networks interacting on local and global scales. We investigated two information-theoretic measures of functional brain segregation and integration—interaction complexity CI(X), and integration I(X)—as applied to electroencephalographic (EEG) signals and how these measures are affected by choice of EEG reference. CI(X) is a statistical measure of the system entropy accounted for by interactions among its elements, whereas I(X) indexes the overall deviation from statistical independence of the individual elements of a system. We recorded 72 channels of scalp EEG from human participants who sat in a wakeful resting state (interleaved counterbalanced eyes-open and eyes-closed blocks). CI(X) and I(X) of the EEG signals were computed using four different EEG references: linked-mastoids (LM) reference, average (AVG) reference, a Laplacian (LAP) “reference-free” transformation, and an infinity (INF) reference estimated via the Reference Electrode Standardization Technique (REST). Fourier-based power spectral density (PSD), a standard measure of resting state activity, was computed for comparison and as a check of data integrity and quality. We also performed dipole source modeling in order to assess the accuracy of neural source CI(X) and I(X) estimates obtained from scalp-level EEG signals. CI(X) was largest for the LAP transformation, smallest for the LM reference, and at intermediate values for the AVG and INF references. I(X) was smallest for the LAP transformation, largest for the LM reference, and at intermediate values for the AVG and INF references. Furthermore, across all references, CI(X) and I(X) reliably distinguished between resting-state conditions (larger values for eyes-open vs. eyes-closed). These findings occurred in the context of the overall expected pattern of resting state PSD. Dipole modeling showed that simulated scalp EEG-level CI(X) and I(X) reflected changes in underlying neural source dependencies, but only for higher levels of integration and with highest accuracy for the LAP transformation. Our observations suggest that the Laplacian-transformation should be preferred for the computation of scalp-level CI(X) and I(X) due to its positive impact on EEG signal quality and statistics, reduction of volume-conduction, and the higher accuracy this provides when estimating scalp-level EEG complexity and integration. PMID:28790884
Reference values for developing responsive functional outcome measures across the lifespan.
McKay, Marnee J; Baldwin, Jennifer N; Ferreira, Paulo; Simic, Milena; Vanicek, Natalie; Burns, Joshua
2017-04-18
To generate a reference dataset of commonly performed functional outcome measures in 1,000 children and adults and investigate the influence of demographic, anthropometric, strength, and flexibility characteristics. Twelve functional outcome measures were collected from 1,000 healthy individuals aged 3-101 years: 6-minute walk test, 30-second chair stand test, timed stairs test, long jump, vertical jump, choice stepping reaction time, balance (Star Excursion Balance Test, tandem stance eyes open and closed, single-leg stance eyes closed), and dexterity (9-hole peg test, Functional Dexterity Test). Correlation and multiple regression analyses were performed to identify factors independently associated with each measure. Age- and sex-stratified reference values for functional outcome measures were generated. Functional performance increased through childhood and adolescence, plateaued during adulthood, and declined in older adulthood. While balance did not differ between the sexes, male participants generally performed better at gross motor tasks while female participants performed better at dexterous tasks. Height was the most consistent correlate of functional performance in children, while lower limb muscle strength was a major determinant in adolescents and adults. In older adults, age, lower limb strength, and joint flexibility explained up to 63% of the variance in functional measures. These normative reference values provide a framework to accurately track functional decline associated with neuromuscular disorders and assist development and validation of responsive outcome measures for therapeutic trials. © 2017 American Academy of Neurology.
Heinrich, Andreas; Teichgräber, Ulf K; Güttler, Felix V
2015-12-01
The standard ASTM F2119 describes a test method for measuring the size of a susceptibility artifact based on the example of a passive implant. A pixel in an image is considered to be a part of an image artifact if the intensity is changed by at least 30% in the presence of a test object, compared to a reference image in which the test object is absent (reference value). The aim of this paper is to simplify and accelerate the test method using a histogram-based reference value. Four test objects were scanned parallel and perpendicular to the main magnetic field, and the largest susceptibility artifacts were measured using two methods of reference value determination (reference image-based and histogram-based reference value). The results between both methods were compared using the Mann-Whitney U-test. The difference between both reference values was 42.35 ± 23.66. The difference of artifact size was 0.64 ± 0.69 mm. The artifact sizes of both methods did not show significant differences; the p-value of the Mann-Whitney U-test was between 0.710 and 0.521. A standard-conform method for a rapid, objective, and reproducible evaluation of susceptibility artifacts could be implemented. The result of the histogram-based method does not significantly differ from the ASTM-conform method.
Biomonitoring of 29 trace elements in whole blood from inhabitants of Cotonou (Benin) by ICP-MS.
Yedomon, Brice; Menudier, Alain; Etangs, Florence Lecavelier Des; Anani, Ludovic; Fayomi, Benjamin; Druet-Cabanac, Michel; Moesch, Christian
2017-09-01
This study aimed to investigate the blood concentration of 29 trace elements, metals or metalloids, in a healthy population of Cotonou not directly exposed to metals in order to propose reference values. Blood samples from 70 blood donors were collected in K2 EDTA tubes for trace elements during September 2015 and a questionnaire was used to assess lifestyle exposure. Blood metal concentrations were determined by inductively coupled plasma mass spectrometry (ICP-MS) equipped with a quadrupole-based reaction cell. Among the selected blood donors 51.4% were aged from 18 to 36 years and 49.6% from 37 to 65 years. Among the 29 elements analyzed As, Pb, Mn, Pd, Sb, Co, Se, Sr showed blood concentrations higher than the reference values found in the literature for non-exposed healthy European populations and their geometric means were respectively 5.81; 47.39; 19.71; 1.91; 7.50; 0.66; 163.01; 30.53μg/L. This study provides the first reference value (5th-95th percentiles) for each element in Cotonou, which enables us to carry out further investigations on environmental and occupational exposure. Copyright © 2016 Elsevier GmbH. All rights reserved.
Devlin, Michelle; Painting, Suzanne; Best, Mike
2007-01-01
The EU Water Framework Directive recognises that ecological status is supported by the prevailing physico-chemical conditions in each water body. This paper describes an approach to providing guidance on setting thresholds for nutrients taking account of the biological response to nutrient enrichment evident in different types of water. Indices of pressure, state and impact are used to achieve a robust nutrient (nitrogen) threshold by considering each individual index relative to a defined standard, scale or threshold. These indices include winter nitrogen concentrations relative to a predetermined reference value; the potential of the waterbody to support phytoplankton growth (estimated as primary production); and detection of an undesirable disturbance (measured as dissolved oxygen). Proposed reference values are based on a combination of historical records, offshore (limited human influence) nutrient concentrations, literature values and modelled data. Statistical confidence is based on a number of attributes, including distance of confidence limits away from a reference threshold and how well the model is populated with real data. This evidence based approach ensures that nutrient thresholds are based on knowledge of real and measurable biological responses in transitional and coastal waters.
Tracer Kinetic Analysis of (S)-¹⁸F-THK5117 as a PET Tracer for Assessing Tau Pathology.
Jonasson, My; Wall, Anders; Chiotis, Konstantinos; Saint-Aubert, Laure; Wilking, Helena; Sprycha, Margareta; Borg, Beatrice; Thibblin, Alf; Eriksson, Jonas; Sörensen, Jens; Antoni, Gunnar; Nordberg, Agneta; Lubberink, Mark
2016-04-01
Because a correlation between tau pathology and the clinical symptoms of Alzheimer disease (AD) has been hypothesized, there is increasing interest in developing PET tracers that bind specifically to tau protein. The aim of this study was to evaluate tracer kinetic models for quantitative analysis and generation of parametric images for the novel tau ligand (S)-(18)F-THK5117. Nine subjects (5 with AD, 4 with mild cognitive impairment) received a 90-min dynamic (S)-(18)F-THK5117 PET scan. Arterial blood was sampled for measurement of blood radioactivity and metabolite analysis. Volume-of-interest (VOI)-based analysis was performed using plasma-input models; single-tissue and 2-tissue (2TCM) compartment models and plasma-input Logan and reference tissue models; and simplified reference tissue model (SRTM), reference Logan, and SUV ratio (SUVr). Cerebellum gray matter was used as the reference region. Voxel-level analysis was performed using basis function implementations of SRTM, reference Logan, and SUVr. Regionally averaged voxel values were compared with VOI-based values from the optimal reference tissue model, and simulations were made to assess accuracy and precision. In addition to 90 min, initial 40- and 60-min data were analyzed. Plasma-input Logan distribution volume ratio (DVR)-1 values agreed well with 2TCM DVR-1 values (R(2)= 0.99, slope = 0.96). SRTM binding potential (BP(ND)) and reference Logan DVR-1 values were highly correlated with plasma-input Logan DVR-1 (R(2)= 1.00, slope ≈ 1.00) whereas SUVr(70-90)-1 values correlated less well and overestimated binding. Agreement between parametric methods and SRTM was best for reference Logan (R(2)= 0.99, slope = 1.03). SUVr(70-90)-1 values were almost 3 times higher than BP(ND) values in white matter and 1.5 times higher in gray matter. Simulations showed poorer accuracy and precision for SUVr(70-90)-1 values than for the other reference methods. SRTM BP(ND) and reference Logan DVR-1 values were not affected by a shorter scan duration of 60 min. SRTM BP(ND) and reference Logan DVR-1 values were highly correlated with plasma-input Logan DVR-1 values. VOI-based data analyses indicated robust results for scan durations of 60 min. Reference Logan generated quantitative (S)-(18)F-THK5117 DVR-1 parametric images with the greatest accuracy and precision and with a much lower white-matter signal than seen with SUVr(70-90)-1 images. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Lunar Ultraviolet Telescope Experiment (LUTE), phase A
NASA Technical Reports Server (NTRS)
Mcbrayer, Robert O.
1994-01-01
The Lunar Ultraviolet Telescope Experiment (LUTE) is a 1-meter telescope for imaging from the lunar surface the ultraviolet spectrum between 1,000 and 3,500 angstroms. There have been several endorsements of the scientific value of a LUTE. In addition to the scientific value of LUTE, its educational value and the information it can provide on the design of operating hardware for long-term exposure in the lunar environment are important considerations. This report provides the results of the LUTE phase A activity begun at the George C. Marshall Space Flight Center in early 1992. It describes the objective of LUTE (science, engineering, and education), a feasible reference design concept that has evolved, and the subsystem trades that were accomplished during the phase A.
Anatomical parameterization for volumetric meshing of the liver
NASA Astrophysics Data System (ADS)
Vera, Sergio; González Ballester, Miguel A.; Gil, Debora
2014-03-01
A coordinate system describing the interior of organs is a powerful tool for a systematic localization of injured tissue. If the same coordinate values are assigned to specific anatomical landmarks, the coordinate system allows integration of data across different medical image modalities. Harmonic mappings have been used to produce parametric coordinate systems over the surface of anatomical shapes, given their flexibility to set values at specific locations through boundary conditions. However, most of the existing implementations in medical imaging restrict to either anatomical surfaces, or the depth coordinate with boundary conditions is given at sites of limited geometric diversity. In this paper we present a method for anatomical volumetric parameterization that extends current harmonic parameterizations to the interior anatomy using information provided by the volume medial surface. We have applied the methodology to define a common reference system for the liver shape and functional anatomy. This reference system sets a solid base for creating anatomical models of the patient's liver, and allows comparing livers from several patients in a common framework of reference.
Labonté, Josiane; Roy, Jean-Philippe; Dubuc, Jocelyn; Buczinski, Sébastien
2015-06-01
Cardiac troponin I (cTnI) has been shown to be an accurate predictor of myocardial injury in cattle. The point-of-care i-STAT 1 immunoassay can be used to quantify blood cTnI in cattle. However, the cTnI reference interval in whole blood of healthy early lactating dairy cows remains unknown. To determine a blood cTnI reference interval in healthy early lactating Holstein dairy cows using the analyzer i-STAT 1. Forty healthy lactating dairy Holstein cows (0-60 days in milk) were conveniently selected from four commercial dairy farms. Each selected cow was examined by a veterinarian and transthoracic echocardiography was performed. A cow-side blood cTnI dosage was measured at the same time. A bootstrap statistical analysis method using unrestricted resampling was used to determine a reference interval for blood cTnI values. Forty healthy cows were recruited in the study. Median blood cTnI was 0.02 ng/mL (minimum: 0.00, maximum: 0.05). Based on the bootstrap analysis method with 40 cases, the 95th percentile of cTnI values in healthy cows was 0.036 ng/mL (90% CI: 0.02-0.05 ng/mL). A reference interval for blood cTnI values in healthy lactating cows was determined. Further research is needed to determine whether cTnI blood values could be used to diagnose and provide a prognosis for cardiac and noncardiac diseases in lactating dairy cows. Copyright © 2015 Elsevier B.V. All rights reserved.
How to estimate recoverable heat energy in wood or bark fuels
P. J. Ince
1979-01-01
A reference source is provided for estimating the amount of heat energy that may be recovered using wood or bark fuel in typical furnace and boiler or hot air combustion heat recovery systems. A survey of reported data on higher heating values for various species of wood and bark fuels is provided. A set of formulas of a type commonly used by combustion technologists...
USDA-ARS?s Scientific Manuscript database
Workshops sponsored by the Institute of Medicine (IOM) and the World Health Organization (WHO) suggested that incorporating systematic reviews into the process of updating nutrient reference values would enhance the transparency of the process. The IOM issues the Dietary Reference Intake values (DR...
Wang, Hubiao; Wu, Lin; Chai, Hua; Xiao, Yaofei; Hsu, Houtse; Wang, Yong
2017-08-10
The variation of a marine gravity anomaly reference map is one of the important factors that affect the location accuracy of INS/Gravity integrated navigation systems in underwater navigation. In this study, based on marine gravity anomaly reference maps, new characteristic parameters of the gravity anomaly were constructed. Those characteristic values were calculated for 13 zones (105°-145° E, 0°-40° N) in the Western Pacific area, and simulation experiments of gravity matching-aided navigation were run. The influence of gravity variations on the accuracy of gravity matching-aided navigation was analyzed, and location accuracy of gravity matching in different zones was determined. Studies indicate that the new parameters may better characterize the marine gravity anomaly. Given the precision of current gravimeters and the resolution and accuracy of reference maps, the location accuracy of gravity matching in China's Western Pacific area is ~1.0-4.0 nautical miles (n miles). In particular, accuracy in regions around the South China Sea and Sulu Sea was the highest, better than 1.5 n miles. The gravity characteristic parameters identified herein and characteristic values calculated in various zones provide a reference for the selection of navigation area and planning of sailing routes under conditions requiring certain navigational accuracy.
Wang, Hubiao; Chai, Hua; Xiao, Yaofei; Hsu, Houtse; Wang, Yong
2017-01-01
The variation of a marine gravity anomaly reference map is one of the important factors that affect the location accuracy of INS/Gravity integrated navigation systems in underwater navigation. In this study, based on marine gravity anomaly reference maps, new characteristic parameters of the gravity anomaly were constructed. Those characteristic values were calculated for 13 zones (105°–145° E, 0°–40° N) in the Western Pacific area, and simulation experiments of gravity matching-aided navigation were run. The influence of gravity variations on the accuracy of gravity matching-aided navigation was analyzed, and location accuracy of gravity matching in different zones was determined. Studies indicate that the new parameters may better characterize the marine gravity anomaly. Given the precision of current gravimeters and the resolution and accuracy of reference maps, the location accuracy of gravity matching in China’s Western Pacific area is ~1.0–4.0 nautical miles (n miles). In particular, accuracy in regions around the South China Sea and Sulu Sea was the highest, better than 1.5 n miles. The gravity characteristic parameters identified herein and characteristic values calculated in various zones provide a reference for the selection of navigation area and planning of sailing routes under conditions requiring certain navigational accuracy. PMID:28796158
Jo, Bum Seak; Myong, Jun Pyo; Rhee, Chin Kook; Yoon, Hyoung Kyu; Koo, Jung Wan; Kim, Hyoung Ryoul
2018-01-15
The present study aimed to update the prediction equations for spirometry and their lower limits of normal (LLN) by using the lambda, mu, sigma (LMS) method and to compare the outcomes with the values of previous spirometric reference equations. Spirometric data of 10,249 healthy non-smokers (8,776 females) were extracted from the fourth and fifth versions of the Korea National Health and Nutrition Examination Survey (KNHANES IV, 2007-2009; V, 2010-2012). Reference equations were derived using the LMS method which allows modeling skewness (lambda [L]), mean (mu [M]), and coefficient of variation (sigma [S]). The outcome equations were compared with previous reference values. Prediction equations were presented in the following form: predicted value = e{a + b × ln(height) + c × ln(age) + M - spline}. The new predicted values for spirometry and their LLN derived using the LMS method were shown to more accurately reflect transitions in pulmonary function in young adults than previous prediction equations derived using conventional regression analysis in 2013. There were partial discrepancies between the new reference values and the reference values from the Global Lung Function Initiative in 2012. The results should be interpreted with caution for young adults and elderly males, particularly in terms of the LLN for forced expiratory volume in one second/forced vital capacity in elderly males. Serial spirometry follow-up, together with correlations with other clinical findings, should be emphasized in evaluating the pulmonary function of individuals. Future studies are needed to improve the accuracy of reference data and to develop continuous reference values for spirometry across all ages. © 2018 The Korean Academy of Medical Sciences.
Le, Margaret; Flores, David; May, Danica; Gourley, Eric; Nangia, Ajay K
2016-05-01
The evaluation and management of male hypogonadism should be based on symptoms and on serum testosterone levels. Diagnostically this relies on accurate testing and reference values. Our objective was to define the distribution of reference values and assays for free and total testosterone by clinical laboratories in the United States. Upper and lower reference values, assay methodology and source of published reference ranges were obtained from laboratories across the country. A standardized survey was reviewed with laboratory staff via telephone. Descriptive statistics were used to tabulate results. We surveyed a total of 120 laboratories in 47 states. Total testosterone was measured in house at 73% of laboratories. At the remaining laboratories studies were sent to larger centralized reference facilities. The mean ± SD lower reference value of total testosterone was 231 ± 46 ng/dl (range 160 to 300) and the mean upper limit was 850 ± 141 ng/dl (range 726 to 1,130). Only 9% of laboratories where in-house total testosterone testing was performed created a reference range unique to their region. Others validated the instrument recommended reference values in a small number of internal test samples. For free testosterone 82% of laboratories sent testing to larger centralized reference laboratories where equilibrium dialysis and/or liquid chromatography with mass spectrometry was done. The remaining laboratories used published algorithms to calculate serum free testosterone. Reference ranges for testosterone assays vary significantly among laboratories. The ranges are predominantly defined by limited population studies of men with unknown medical and reproductive histories. These poorly defined and variable reference values, especially the lower limit, affect how clinicians determine treatment. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
A New Paradigm for Practice Education.
ERIC Educational Resources Information Center
Edmond, Cynthia B.
2001-01-01
Education for nursing practice must shift to a collaborative education/service model in which the value of practical education and experience is better understood and integrated with academic knowledge. This model provides better resources and availability of mentors/preceptors, resulting in better prepared nurses. (Contains 32 references.) (SK)
Miller, Andrea L; Evans, Alina L; Os, Øystein; Arnemo, Jon M
2013-04-01
Hematologic and serum biochemistry values were evaluated in free-ranging, wild Norwegian reindeer (Rangifer tarandus tarandus) as part of a reintroduction program in southwestern Norway in November 1995 and 1996. Animals were immobilized with medetomidine-ketamine by dart from a helicopter. Blood was drawn for serum chemistry from 31 adults (nine males and 22 females) and for hematology from 29 adults (eight males and 21 females). Significant differences (P<0.05) were found between male and female results for alkaline phosphatase, selenium, and zinc. Although there was a significant difference between male and female gamma-globulin values and the total albumin:globulin ratio, the overall values are much lower than those reported for other Rangifer species. Sexual differences should be interpreted with caution due to the low number of males compared to females. References ranges are presented combining male and female results for hematology and serum chemistry and separately for males and females for serum electrophoresis. No correlation was found between induction time and aspartate transaminase, creatine kinase, glucose, cortisol, or total protein. Blood values were generally similar to those published for semidomestic reindeer (Rangifer tarandus tarandus) and free-ranging caribou (Rangifer tarandus caribou), but the effect of capture drugs, stress, season, and sample size should be considered with interpretation. This paper provides the first report of baseline hematologic and serum biochemistry reference ranges for free-ranging, wild Norwegian reindeer during early winter.
Poster, Dianne L; Schantz, Michele M; Kucklick, John R; Lopez de Alda, Maria J; Porter, Barbara J; Pugh, Rebecca; Wise, Stephen A
2004-03-01
Three new mussel tissue standard reference materials (SRMs) have been developed by the National Institute of Standards and Technology (NIST) for the determination of the concentrations of organic contaminants. The most recently prepared material, SRM 1974b, is a fresh frozen tissue homogenate prepared from mussels ( Mytilus edulis) collected in Boston Harbor, Massachusetts. The other two materials, SRMs 2977 and 2978, are freeze-dried tissue homogenates prepared from mussels collected in Guanabara Bay, Brazil and Raritan Bay, New Jersey, respectively. All three new mussel tissue SRMs complement the current suite of marine natural-matrix SRMs available from NIST that are characterized for a wide range of contaminants (organic and inorganic). SRM 1974b has been developed to replace its predecessor SRM 1974a, Organics in Mussel Tissue, for which the supply is depleted. Similarly, SRMs 2977 and 2978 were developed to replace a previously available (supply depleted) freeze-dried version of SRM 1974a, SRM 2974, Organics in Freeze-Dried Mussel Tissue. SRM 1974b is the third in a series of fresh frozen mussel tissue homogenate SRMs prepared from mussels collected in Boston Harbor starting in 1988. SRM 1974b has certified concentration values for 22 polycyclic aromatic hydrocarbons (PAHs), 31 polychlorinated biphenyl congeners (PCBs), and 7 chlorinated pesticides. Reference values are provided for additional constituents: 16 PAHs, 8 PCBs plus total PCBs, 6 pesticides, total extractable organics, methylmercury, and 11 trace elements. PAH concentrations range from about 2 ng g(-1 )dry mass (cyclopenta[ cd]pyrene) to 180 ng g(-1 )dry mass (pyrene). PCB concentrations range from about 2 ng g(-1 )dry mass (PCB 157) to 120 ng g(-1 )dry mass (PCB 153). The reference value for total PCBs in SRM 1974b is (2020 +/- 420) ng g(-1 )dry mass. Pesticide concentrations range from about 4 ng g(-1 )dry mass (4,4'-DDT) to 40 ng g(-1 )dry mass (4,4'-DDE). SRM 2977 has certified values for 14 PAHs, 25 PCB congeners, 7 pesticides, 6 trace elements, and methylmercury. Reference values for 16 additional PAHs and 9 inorganic constituents are provided, and information values are given for 23 additional trace elements. SRM 2978 has certified and reference concentrations for 41 and 22 organic compounds, respectively, and contains contaminant levels similar to those of SRM 1974b. Organic contaminant levels in SRM 2977 (mussels from Guanabara Bay, Brazil) are typically a factor of 2 to 4 lower than those in SRM 1974b and SRM 2978. The organic contaminant concentrations in each new mussel tissue SRM are presented and compared in this paper. In addition, a chronological review of contaminant concentrations associated with mussels collected in Boston Harbor is discussed as well as a stability assessment of SRM 1974a.
An Evaluation of the Pea Pod System for Assessing Body Composition of Moderately Premature Infants.
Forsum, Elisabet; Olhager, Elisabeth; Törnqvist, Caroline
2016-04-22
(1) BACKGROUND: Assessing the quality of growth in premature infants is important in order to be able to provide them with optimal nutrition. The Pea Pod device, based on air displacement plethysmography, is able to assess body composition of infants. However, this method has not been sufficiently evaluated in premature infants; (2) METHODS: In 14 infants in an age range of 3-7 days, born after 32-35 completed weeks of gestation, body weight, body volume, fat-free mass density (predicted by the Pea Pod software), and total body water (isotope dilution) were assessed. Reference estimates of fat-free mass density and body composition were obtained using a three-component model; (3) RESULTS: Fat-free mass density values, predicted using Pea Pod, were biased but not significantly (p > 0.05) different from reference estimates. Body fat (%), assessed using Pea Pod, was not significantly different from reference estimates. The biological variability of fat-free mass density was 0.55% of the average value (1.0627 g/mL); (4) CONCLUSION: The results indicate that the Pea Pod system is accurate for groups of newborn, moderately premature infants. However, more studies where this system is used for premature infants are needed, and we provide suggestions regarding how to develop this area.
Korshøj, Mette; Skotte, Jørgen H; Christiansen, Caroline S; Mortensen, Pelle; Kristiansen, Jesper; Hanisch, Christiana; Ingebrigtsen, Jørgen; Holtermann, Andreas
2014-01-01
The validity of inclinometer measurements by ActiGraph GT3X+ (AG) accelerometer, when analysed with the Acti4 customised software, was examined by comparison of inclinometer measurements with a reference system (TrakStar) in a protocol with standardised arm movements and simulated working tasks. The sensors were placed at the upper arm (distal to the deltoid insertion) and at the spine (level of T1-T2) on eight participants. Root mean square errors (RMSEs) values of inclination between the two systems were low for the slow- and medium-speed standardised arm movements and in simulated working tasks. Fast arm movements caused the inclination estimated by the AG to deviate from the reference measurements (RMSE values up to ∼10°). Furthermore, it was found that AG positioned at the upper arm provided inclination data without bias compared to the reference system. These findings indicate that the AG provides valid estimates of arm and upper body inclination in working participants. Being inexpensive, small, water-resistant and without wires, ActiGraph GT3X+ seems to be a valid mean for direct long-term field measurements of arm and trunk inclinations when analysed by the Acti4 customised software.
Multipass Steering: A Reference Implementation
NASA Astrophysics Data System (ADS)
Hennessey, Michael; Tiefenback, Michael
2015-10-01
We introduce a reference implementation of a protocol to compute corrections that bring all beams in one of the CEBAF linear accelerators (linac) to axis, including, with a larger tolerance, the lowest energy pass using measured beam trajectory data. This method relies on linear optics as representation of the system; we treat beamline perturbations as magnetic field errors localized to regions between cryomodules, providing the same transverse momentum kick to each beam. We produce a vector of measured beam position data with which we left-multiply the pseudo-inverse of a coefficient array, A, that describes the transport of the beam through the linac using parameters that include the magnetic offsets of the quadrupole magnets, the instrumental offsets of the BPMs, and the beam initial conditions. This process is repeated using a reduced array to produce values that can be applied to the available correcting magnets and beam initial conditions. We show that this method is effective in steering the beam to a straight axis along the linac by using our values in elegant, the accelerator simulation program, on a model of the linac in question. The algorithms in this reference implementation provide a tool for systematic diagnosis and cataloging of perturbations in the beam line. Supported by Jefferson Lab, Old Dominion University, NSF, DOE.
NASA Astrophysics Data System (ADS)
Kim, Han Sung; Yeom, Yeon Soo; Tat Nguyen, Thang; Choi, Chansoo; Han, Min Cheol; Lee, Jai Ki; Kim, Chan Hyeong; Zankl, Maria; Petoussi-Henss, Nina; Bolch, Wesley E.; Lee, Choonsik; Qiu, Rui; Eckerman, Keith; Chung, Beom Sun
2017-03-01
It is not feasible to define very small or complex organs and tissues in the current voxel-type adult reference computational phantoms of the International Commission on Radiological Protection (ICRP), which limit dose coefficients for weakly penetrating radiations. To address the problem, the ICRP is converting the voxel-type reference phantoms into mesh-type phantoms. In the present study, as a part of the conversion project, the micrometer-thick target and source regions in the alimentary and respiratory tract systems as described in ICRP Publications 100 and 66 were included in the mesh-type ICRP reference adult male and female phantoms. In addition, realistic lung airway models were simulated to represent the bronchial (BB) and bronchiolar (bb) regions. The electron specific absorbed fraction (SAF) values for the alimentary and respiratory tract systems were then calculated and compared with the values calculated with the stylized models of ICRP Publications 100 and 66. The comparisons show generally good agreement for the oral cavity, oesophagus, and BB, whereas for the stomach, small intestine, large intestine, extrathoracic region, and bb, there are some differences (e.g. up to ~9 times in the large intestine). The difference is mainly due to anatomical difference in these organs between the realistic mesh-type phantoms and the simplified stylized models. The new alimentary and respiratory tract models in the mesh-type ICRP reference phantoms preserve the topology and dimensions of the voxel-type ICRP phantoms and provide more reliable SAF values than the simplified models adopted in previous ICRP Publications.
Zhu, Yanbei; Narukawa, Tomohiro; Inagaki, Kazumi; Kuroiwa, Takayoshi; Chiba, Koichi
2011-01-01
A certified reference material (CRM) for trace elements in tea leaves has been developed in National Metrology Institute of Japan (NMIJ). The CRM was provided as a dry powder (<90 µm) after frozen pulverization of washed and dried fresh tea leaves from a tea plant farm in Shizuoka Prefecture, Japan. Characterization of the property value for each element was carried out exclusively by NMIJ with at least two independent analytical methods, including inductively coupled plasma mass spectrometry (ICP-MS), high-resolution (HR-) ICP-MS, isotope-dilution (ID-) ICP-MS, inductively coupled plasma optical emission spectrometry (ICP-OES), graphite-furnace atomic-absorption spectrometry (GF-AAS) and flame atomic-absorption spectrometry (FAAS). Property values were provided for 19 elements (Ca, K, Mg, P, Al, B, Ba, Cd, Cu, Fe, Li, Mn, Na, Ni, Pb, Rb, Sr, Zn and Co) and informative values for 18 elements (Ti, V, Cr, Y, and all of the lanthanides, except for Pm whose isotopes are exclusively radioactive). The concentration ranges of property values and informative values were from 1.59% (mass) of K to 0.0139 mg kg(-1) of Cd and from 0.6 mg kg(-1) of Ti to 0.0014 mg kg(-1) of Lu, respectively. Combined relatively standard uncertainties of the property values were estimated by considering the uncertainties of the homogeneity, analytical methods, characterization, calibration standard, and dry-mass correction factor. The range of the relative combined standard uncertainties was from 1.5% of Mg and K to 4.1% of Cd.
Kernis, Michael H
2005-12-01
In this article, I report on a research program that has focused on the joint roles of stability and level of self-esteem in various aspects of psychological functioning. Stability of self-esteem refers to the magnitude of short-term fluctuations that people experience in their current, contextually based feelings of self-worth. In contrast, level of self-esteem refers to representations of people's general, or typical, feelings of self-worth. A considerable amount of research reveals that self-esteem stability has predictive value beyond the predictive value of self-esteem level. Moreover, considering self-esteem stability provides one way to distinguish fragile from secure forms of high self-esteem. Results from a number of studies are presented and theoretical implications are discussed.
Findlay, R P; Dimbylow, P J
2009-04-21
If an antenna is located close to a person, the electric and magnetic fields produced by the antenna will vary in the region occupied by the human body. To obtain a mean value of the field for comparison with reference levels, the Institute of Electrical and Electronic Engineers (IEEE) and International Commission on Non-Ionizing Radiation Protection (ICNIRP) recommend spatially averaging the squares of the field strength over the height the body. This study attempts to assess the validity and accuracy of spatial averaging when used for half-wave dipoles at frequencies between 65 MHz and 2 GHz and distances of lambda/2, lambda/4 and lambda/8 from the body. The differences between mean electric field values calculated using ten field measurements and that of the true averaged value were approximately 15% in the 600 MHz to 2 GHz range. The results presented suggest that the use of modern survey equipment, which takes hundreds rather than tens of measurements, is advisable to arrive at a sufficiently accurate mean field value. Whole-body averaged and peak localized SAR values, normalized to calculated spatially averaged fields, were calculated for the NORMAN voxel phantom. It was found that the reference levels were conservative for all whole-body SAR values, but not for localized SAR, particularly in the 1-2 GHz region when the dipole was positioned very close to the body. However, if the maximum field is used for normalization of calculated SAR as opposed to the lower spatially averaged value, the reference levels provide a conservative estimate of the localized SAR basic restriction for all frequencies studied.
Kainu, Annette; Lindqvist, Ari; Sovijärvi, Anssi R. A.
2016-01-01
Background New Finnish (Kainu2015) and international Global Lung Function Initiative (GLI2012) reference values for spirometry were recently published. The aim of this study is to compare the interpretative consequences of adopting these new reference values with older, currently used Finnish reference values (Viljanen1982) in the general population of native Finns. Methods Two Finnish general population samples including 1,328 adults (45% males) aged 21–74 years were evaluated. Airway obstruction was defined as a reduced ratio of forced expiratory volume in one second (FEV1)/forced vital capacity (FVC), possible restrictive pattern as reduced FVC, and decreased ventilatory capacity as reduced FEV1 below their respective 2.5th percentiles. The severity gradings of reduced lung function were also compared. Results Using the Kainu2015 reference values, the prevalence of airway obstruction in the population was 5.6%; using GLI2012 it was 4.0% and with Viljanen1982 it was 13.0%. Possible restrictive pattern was found in 4.2% using the Kainu2015 values, in 2.0% with GLI2012, and 7.9% with the Viljanen1982 values. The prevalence of decreased ventilatory capacity was 6.8, 4.0, and 13.3% with the Kainu2015, GLI2012 and Viljanen1982 values, respectively. Conclusions The application of the GLI2012 reference values underestimates the prevalence of abnormal spirometric findings in native Finns. The adoption of the Kainu2015 reference values reduces the prevalences of airways obstruction, decreased ventilatory capacity, and restrictive impairment by approximately 50%. Changing from the 2.5th percentile, the previously used lower limit of normal, to the 5th percentile recommended by the American Thoracic Society/European Respiratory Society will not increase the prevalence of abnormal findings in the implementation of spirometry reference values. PMID:27608270
Qayyum, Aisha; Najmi, Muzammil Hasan; Abbas, Mateen
2013-11-01
Comparative bioavailability studies are conducted to establish the bioequivalence of generic formulation with that of branded reference formulation, providing confidence to clinicians to use these products interchangeably. This study was carried out to compare a locally manufactured formulation of flurbiprofen with that of a branded product. Twenty two healthy male adults received a single dose of flurbiprofen (100mg) either generic or branded product according to randomization scheme on each of 2 periods. Blood samples were collected and plasma flurbiprofen concentration was determined by a validated HPLC method. Pharmacokinetic parameters like AUC(0-t), AUC(0-oo), Cmax, Tmax, t½, Vd and clearance were determined. The 90% CI for the ratio of geometric means of test to reference product's pharmacokinetic variables was calculated. Pharmacokinetic parameters for two formulations were comparable. Ratio of means of AUC(0-24), AUC(0-oo) and Cmax for test to reference products and 90% CI for these ratios were within the acceptable range. The p-values calculated by TOST were much less than the specified value (p-0.05). ANOVA gave p-values which were more than the specified value (p-0.05) for sequence, subject, period and formulation. Test formulation of flurbiprofen (tablet Flurso) was found to meet the criteria for bioequivalence to branded product (tablet Ansaid) based on pharmacokinetic parameters.
Notes on numerical reliability of several statistical analysis programs
Landwehr, J.M.; Tasker, Gary D.
1999-01-01
This report presents a benchmark analysis of several statistical analysis programs currently in use in the USGS. The benchmark consists of a comparison between the values provided by a statistical analysis program for variables in the reference data set ANASTY and their known or calculated theoretical values. The ANASTY data set is an amendment of the Wilkinson NASTY data set that has been used in the statistical literature to assess the reliability (computational correctness) of calculated analytical results.
van den Berg, K E M; Rijnders, C A Th; van Dam, A; van de Ven, A L M; van der Feltz-Cornelis, C M; Graafsma, S J
2014-01-01
It is well-known that psychiatric patients often suffer from severe somatic problems, such as diabetes mellitus and cardiovascular disease. Up till now, research has concentrated almost exclusively on the inpatient setting, but there is strong evidence that the correlation also exists in psychiatric patients who are outpatients. In the Netherlands there are, as yet, no clear recommendations regarding a standard form of somatic screening for the outpatient population. A pilot study performed by GGz Breburg has shown that somatic screening (without a physical examination) gave substantial additional value to treatment planning. To investigate the added value that a physical examination can provide when new psychiatric patients are screened for aspects of somatic concern (ASC). Newly referred outpatients (n = 70) were screened somatically by means of a questionnaire and supplementary medical interview, and by laboratory tests and physical examination. If a somatic problem was found which had not been detected previously, the patient was referred back to to the general practitioner. At least one ASC was found in 81,4% of all patients. In 45,7% of all patients the asc had not been detected. 12% of all the newly discovered somatic problems were found exclusively via the physical examination. A physical examination provides substantial information and adds value to the somatic screening of psychiatric outpatients.
The theory of reference values: an unfinished symphony.
Siest, Gerard; Henny, Joseph; Gräsbeck, Ralph; Wilding, Peter; Petitclerc, Claude; Queraltó, Josep M; Hyltoft Petersen, Peter
2013-01-01
The history of the theory of reference values can be written as an unfinished symphony. The first movement, allegro con fuoco, played from 1960 to 1980: a mix of themes devoted to the study of biological variability (intra-, inter-individual, short- and long-term), preanalytical conditions, standardization of analytical methods, quality control, statistical tools for deriving reference limits, all of them complex variations developed on a central melody: the new concept of reference values that would replace the notion of normality whose definition was unclear. Additional contributions (multivariate reference values, use of reference limits from broad sets of patient data, drug interferences) conclude the movement on the variability of laboratory tests. The second movement, adagio, from 1980 to 2000, slowly develops and implements initial works. International and national recommendations were published by the IFCC-LM (International Federation of Clinical Chemistry and Laboratory Medicine) and scientific societies [French (SFBC), Spanish (SEQC), Scandinavian societies…]. Reference values are now topics of many textbooks and of several congresses, workshops, and round tables that are organized all over the world. Nowadays, reference values are part of current practice in all clinical laboratories, but not without difficulties, particularly for some laboratories to produce their own reference values and the unsuitability of the concept with respect to new technologies such as HPLC, GCMS, and PCR assays. Clinicians through consensus groups and practice guidelines have introduced their own tools, the decision limits, likelihood ratios and Reference Change Value (RCV), creating confusion among laboratorians and clinicians in substituting reference values and decision limits in laboratory reports. The rapid development of personalized medicine will eventually call for the use of individual reference values. The beginning of the second millennium is played allegro ma non-troppo from 2000 to 2012: the theory of reference values is back into fashion. The need to revise the concept is emerging. The manufacturers make a friendly pressure to facilitate the integration of Reference Intervals (RIs) in their technical documentation. Laboratorians are anxiously awaiting the solutions for what to do. The IFCC-LM creates Reference Intervals and Decision Limits Committee (C-RIDL) in 2005. Simultaneously, a joint working group IFCC-CLSI is created on the same topic. In 2008 the initial recommendations of IFCC-LM are revised and new guidelines are published by the Clinical and Laboratory Standards Institute (CLSI C28-A3). Fundamentals of the theory of reference values are not changed, but new avenues are explored: RIs transference, multicenter reference intervals, and a robust method for deriving RIs from small number of subjects. Concomitantly, other statistical methods are published such as bootstraps calculation and partitioning procedures. An alternative to recruiting healthy subjects proposes the use of biobanks conditional to the availability of controlled preanalytical conditions and of bioclinical data. The scope is also widening to include veterinary biology! During the early 2000s, several groups proposed the concept of 'Universal RIs' or 'Global RIs'. Still controversial, their applications await further investigations. The fourth movement, finale: beyond the methodological issues (statistical and analytical essentially), important questions remain unanswered. Do RIs intervene appropriately in medical decision-making? Are RIs really useful to the clinicians? Are evidence-based decision limits more appropriate? It should be appreciated that many laboratory tests represent a continuum that weakens the relevance of RIs. In addition, the boundaries between healthy and pathological states are shady areas influenced by many biological factors. In such a case the use of a single threshold is questionable. Wherever it will apply, individual reference values and reference change values have their place. A variation on an old theme! It is strange that in the period of personalized medicine (that is more stratified medicine), the concept of reference values which is based on stratification of homogeneous subgroups of healthy people could not be discussed and developed in conjunction with the stratification of sick patients. That is our message for the celebration of the 50th anniversary of Clinical Chemistry and Laboratory Medicine. Prospects are broad, enthusiasm is not lacking: much remains to be done, good luck for the new generations!
Nonparametric spirometry reference values for Hispanic Americans.
Glenn, Nancy L; Brown, Vanessa M
2011-02-01
Recent literature sites ethnic origin as a major factor in developing pulmonary function reference values. Extensive studies established reference values for European and African Americans, but not for Hispanic Americans. The Third National Health and Nutrition Examination Survey defines Hispanic as individuals of Spanish speaking cultures. While no group was excluded from the target population, sample size requirements only allowed inclusion of individuals who identified themselves as Mexican Americans. This research constructs nonparametric reference value confidence intervals for Hispanic American pulmonary function. The method is applicable to all ethnicities. We use empirical likelihood confidence intervals to establish normal ranges for reference values. Its major advantage: it is model free, but shares asymptotic properties of model based methods. Statistical comparisons indicate that empirical likelihood interval lengths are comparable to normal theory intervals. Power and efficiency studies agree with previously published theoretical results.
Ning, Lei; Song, Li-Jiang; Fan, Shun-Wu; Zhao, Xing; Chen, Yi-Lei; Li, Zhao-Zhi; Hu, Zi-Ang
2017-10-11
This study established gender-specific reference values in mainland Chinese (MC) and is important for quantitative morphometry for diagnosis and epidemiological study of osteoporotic vertebral compressive fracture. Comparisons of reference values among different racial populations are then performed to demonstrate the MC-specific characteristic. Osteoporotic vertebral compressive fracture (OVCF) is a common complication of osteoporosis in the elder population. Clinical diagnosis and epidemiological study of OVCF often employ quantitative morphometry, which relies heavily on the comparison of patients' vertebral parameters to existing reference values derived from the normal population. Thus, reference values are crucial in clinical diagnosis. To our knowledge, this is the first study to establish reference values of the mainland Chinese (MC) for quantitative morphometry. Vertebral heights including anterior (Ha), middle (Hm), posterior (Hp) heights, and predicted posterior height (pp) from T4 to L5 were obtained; and ratios of Ha/Hp, Hm/Hp and Hp/pp. were calculated from 585 MC (both female and male) for establishing reference values and subsequent comparisons with other studies. Vertebral heights increased progressively from T4 to L3 but then decreased in L4 and L5. Both genders showed similar ratios of vertebral dimensions, but male vertebrae were statistically larger than those of female (P < 0.01). Vertebral size of MC population was smaller than that of US and UK population, but was surprisingly larger than that of Hong Kong Chinese, although these two are commonly considered as one race. Data from different racial populations showed similar dimensional ratios in all vertebrae. We established gender-specific reference values for MC. Our results also indicated the necessity of establishing reference values that are not only race- and gender-specific, but also population- or region-specific for accurate quantitative morphometric assessment of OVCF.
Kilburn, K H; Warshaw, R H; Thornton, J C; Thornton, K; Miller, A
1992-01-01
BACKGROUND: Published predicted values for total lung capacity and residual volume are often based on a small number of subjects and derive from different populations from predicted spirometric values. Equations from the only two large studies gave smaller predicted values for total lung capacity than the smaller studies. A large number of subjects have been studied from a population which has already provided predicted values for spirometry and transfer factor for carbon monoxide. METHODS: Total lung capacity was measured from standard posteroanterior and lateral chest radiographs and forced vital capacity by spirometry in a population sample of 771 subjects. Prediction equations were developed for total lung capacity (TLC), residual volume (RV) and RV/TLC in two groups--normal and total. Subjects with signs or symptoms of cardiopulmonary disease were combined with the normal subjects and equations for all subjects were also modelled. RESULTS: Prediction equations for TLC and RV in non-smoking normal men and women were square root transformations which included height and weight but not age. They included a coefficient for duration of smoking in current smokers. The predictive equation for RV/TLC included weight, age, age and duration of smoking for current smokers and ex-smokers of both sexes. For the total population the equations took the same form but the height coefficients and constants were slightly different. CONCLUSION: These population based prediction equations for TLC, RV and RV/TLC provide reference standards in a population that has provided reference standards for spirometry and single breath transfer factor for carbon monoxide. PMID:1412094
Escobar, Raul G; Munoz, Karin T; Dominguez, Angelica; Banados, Pamela; Bravo, Maria J
2017-01-01
In this study we aimed to determine the maximal isometric muscle strength of a healthy, normal-weight, pediatric population between 6 and 15 years of age using hand-held dynamometry to establish strength reference values. The secondary objective was determining the relationship between strength and anthropometric parameters. Four hundred normal-weight Chilean children, split into 10 age groups, separated by 1-year intervals, were evaluated. Each age group included between 35 and 55 children. The strength values increased with increasing age and weight, with a correlation of 0.83 for age and 0.82 for weight. The results were similar to those reported in previous studies regarding the relationships among strength, age, and anthropometric parameters, but the reported strength differed. These results provide normal strength parameters for healthy and normal-weight Chilean children between 6 and 15 years of age and highlight the relevance of ethnicity in defining reference values for muscle strength in a pediatric population. Muscle Nerve 55: 16-22, 2017. © 2016 Wiley Periodicals, Inc.
75 FR 56892 - Fenarimol; Pesticide Tolerance
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-17
... requests are provided in 40 CFR 178.25(b). In addition to filing an objection or hearing request with the... toxicological POD is used as the basis for derivation of reference values for risk assessment. PODs are...) monitoring data for apples, bananas, cherries, grapes, and pears. Field trial residue data were used for...
A Complete Art Instructor Demonstration: Composition and Value.
ERIC Educational Resources Information Center
Demery, Marie
A complete art instructor demonstration consists of the following components: (1) goals and/or objectives; (2) examples; (3) vocabulary; (4) media; (5) steps; (6) evaluation criteria; and (7) references. A lesson plan is provided which encompasses those components and becomes the guiding structure for instructional and student organization,…
Subjective Expected Utility: A Model of Decision-Making.
ERIC Educational Resources Information Center
Fischoff, Baruch; And Others
1981-01-01
Outlines a model of decision making known to researchers in the field of behavioral decision theory (BDT) as subjective expected utility (SEU). The descriptive and predictive validity of the SEU model, probability and values assessment using SEU, and decision contexts are examined, and a 54-item reference list is provided. (JL)
Thermometric convection coefficients for rocket meteorological sensors (tables)
NASA Technical Reports Server (NTRS)
Staffanson, F. L.
1974-01-01
Values of the convective heat transfer coefficient h, and the recovery factor r, for miniature beads, fine wires, and films in rarefied air flow are shown. Data provide a standard reference for computing consistent operational corrections to rocket meteorological measurements, and for predicting the performance of existing and proposed sensor systems.
Evaluation of Density Functionals and Basis Sets for Carbohydrates
USDA-ARS?s Scientific Manuscript database
Correlated ab initio wave function calculations using MP2/aug-cc-pVTZ model chemistry have been performed for three test sets of gas phase saccharide conformations to provide reference values for their relative energies. The test sets consist of 15 conformers of alpha and beta-D-allopyranose, 15 of ...
Validity and Reliability of a Glucometer Against Industry Reference Standards.
Salacinski, Amanda J; Alford, Micah; Drevets, Kathryn; Hart, Sarah; Hunt, Brian E
2014-01-01
As an appealing alternative to reference glucose analyzers, portable glucometers are recommended for self-monitoring at home, in the field, and in research settings. The purpose was to characterize the accuracy and precision, and bias of glucometers in biomedical research. Fifteen young (20-36 years; mean = 24.5), moderately to highly active men (n = 10) and women (n = 5), defined by exercising 2 to 3 times a week for the past 6 months, were given an oral glucose tolerance test (OGTT) after an overnight fast. Participants ingested 50, 75, or 150 grams of glucose over a 5-minute period. The glucometer was compared to a reference instrument. The glucometer had 39% of values within 15% of measurements made using the reference instrument ranging from 45.05 to 169.37 mg/dl. There was both a proportional (-0.45 to -0.39) and small fixed (5.06 and 0.90 mg/dl) bias. Results of the present study suggest that the glucometer provided poor validity and reliability results compared to the results provided by the reference laboratory analyzer. The portable glucometers should be used for patient management, but not for diagnosis, treatment, or research purposes. © 2014 Diabetes Technology Society.
Kenney, Terry A.
2010-01-01
Operational procedures at U.S. Geological Survey gaging stations include periodic leveling checks to ensure that gages are accurately set to the established gage datum. Differential leveling techniques are used to determine elevations for reference marks, reference points, all gages, and the water surface. The techniques presented in this manual provide guidance on instruments and methods that ensure gaging-station levels are run to both a high precision and accuracy. Levels are run at gaging stations whenever differences in gage readings are unresolved, stations may have been damaged, or according to a pre-determined frequency. Engineer's levels, both optical levels and electronic digital levels, are commonly used for gaging-station levels. Collimation tests should be run at least once a week for any week that levels are run, and the absolute value of the collimation error cannot exceed 0.003 foot/100 feet (ft). An acceptable set of gaging-station levels consists of a minimum of two foresights, each from a different instrument height, taken on at least two independent reference marks, all reference points, all gages, and the water surface. The initial instrument height is determined from another independent reference mark, known as the origin, or base reference mark. The absolute value of the closure error of a leveling circuit must be less than or equal to ft, where n is the total number of instrument setups, and may not exceed |0.015| ft regardless of the number of instrument setups. Closure error for a leveling circuit is distributed by instrument setup and adjusted elevations are determined. Side shots in a level circuit are assessed by examining the differences between the adjusted first and second elevations for each objective point in the circuit. The absolute value of these differences must be less than or equal to 0.005 ft. Final elevations for objective points are determined by averaging the valid adjusted first and second elevations. If final elevations indicate that the reference gage is off by |0.015| ft or more, it must be reset.
Arkuszewski, M; Krejza, J; Chen, R; Kwiatkowski, J L; Ichord, R; Zimmerman, R; Ohene-Frempong, K; Desiderio, L; Melhem, E R
2011-09-01
TCD screening is widely used to identify children with SCD at high risk of stroke. Those with high mean flow velocities in major brain arteries have increased risk of stroke. Thus, our aim was to establish reference values of interhemispheric differences and ratios of blood flow Doppler parameters in the tICA, MCA, and ACA as determined by conventional TCD in children with sickle cell anemia. Reference limits of blood flow parameters were established on the basis of a consecutive cohort of 56 children (mean age, 100 ± 40 months; range, 29-180 months; 30 females) free of neurologic deficits and intracranial stenosis detectable by MRA, with blood flow velocities <170 cm/s by conventional TCD. Reference limits were estimated by using tolerance intervals, within which are included with a probability of .90 of all possible data values from 95% of a population. Average peak systolic velocities were significantly higher in the right hemisphere in the MCA and ACA (185 ± 28 cm/s versus 179 ± 27 and 152 ± 30 cm/s versus 143 ± 34 cm/s respectively). Reference limits for left-to-right differences in the mean flow velocities were the following: -43 to 33 cm/s for the MCA; -49 to 38 cm/s for the ACA, and -38 to 34 cm/s for the tICA, respectively. Respective reference limits for left-to-right velocity ratios were the following: 0.72 to 1.25 cm/s for the MCA; 0.62 to 1.39 cm/s for the ACA, and 0.69 to 1.27 cm/s for the tICA. Flow velocities in major arteries were inversely related to age and Hct or Hgb. The study provides reference intervals of TCD flow velocities and their interhemispheric differences and ratios that may be helpful in identification of intracranial arterial stenosis in children with SCD undergoing sonographic screening for stroke prevention.
dos Santos, Sabrina Novaes; Alleoni, Luís Reynaldo Ferracciú
2013-07-01
Guideline values are used to identify polluted or contaminated areas based on background values. Brazilian law establishes three guideline values for pollutants: a quality reference value (QRV), a prevention value, and an intervention value. Reference values refer to the natural concentration of an element or a substance in soils that have not been modified by anthropogenic impacts. These values inform assessments of soil quality and are used to establish maximum permissible limits. The objective of this study was to determine the natural levels and reference values for Cd, Co, Cr, Cu, Ni, Pb, and Zn in samples from the surface layer (0-20 cm) of 19 representative soils of the states of Mato Grosso and Rondônia, on Brazil's agricultural frontier. Pseudo-total metal concentrations were obtained following microwave-assisted digestion using the aqua regia and EPA3051 methods. QRVs were calculated for each element as the 75th and 90th percentiles of the frequency distribution of the data. Natural levels of heavy metals in the soil samples followed the order: Cr > Zn > Cu > Co > Pb > Ni > and Cd (aqua regia) and Cr > Co > Cu > Pb > Zn > Ni > Cd (EPA3051). These values are generally lower than those reported in the Brazilian and international literature, which highlights the importance of establishing reference values for each state or for each soil type, taking into account the geomorphological, pedological, and geological diversity of the region under study.
Discrimination of human and nonhuman blood using Raman spectroscopy with self-reference algorithm
NASA Astrophysics Data System (ADS)
Bian, Haiyi; Wang, Peng; Wang, Jun; Yin, Huancai; Tian, Yubing; Bai, Pengli; Wu, Xiaodong; Wang, Ning; Tang, Yuguo; Gao, Jing
2017-09-01
We report a self-reference algorithm to discriminate human and nonhuman blood by calculating the ratios of identification Raman peaks to reference Raman peaks and choosing appropriate threshold values. The influence of using different reference peaks and identification peaks was analyzed in detail. The Raman peak at 1003 cm-1 was proved to be a stable reference peak to avoid the influencing factors, such as the incident laser intensity and the amount of sample. The Raman peak at 1341 cm-1 was found to be an efficient identification peak, which indicates that the difference between human and nonhuman blood results from the C-H bend in tryptophan. The comparison between self-reference algorithm and partial least square method was made. It was found that the self-reference algorithm not only obtained the discrimination results with the same accuracy, but also provided information on the difference of chemical composition. In addition, the performance of self-reference algorithm whose true positive rate is 100% is significant for customs inspection to avoid genetic disclosure and forensic science.
NASA Astrophysics Data System (ADS)
Sholihin; Susanti, Eka
2018-02-01
The development of increasingly advanced technology, make people want to be more developed and curiosity to know more to determine the development of advanced technology. Robot is a tool that can be used as a tool for people who have several advantages. Basically humanoid robot is a robot that resembles a human being with all the driving structure. In the application of this humanoid robot manufacture researchers use MPU6050 module which is an important component of the robot because it can provide a response to the angle reference axis X and Y reference axis, the reading corner still has noise if not filtered out beforehand. On the other hand the use of Complementary filters are the answer to reduce the noise. By arranging the filter coefficients and time sampling filter that affects the signal updates corner. The angle value will be the value of the sensor to the process to the PID system which generates output values that are integrated with the servo pulses. Researchers will test to get a reading of the most stable angle for this experiment is the "a" or the value of the filter coefficient = 0.96 and "dt" or the sampling time = 10 ms.
Díaz, Alejandro; Galli, Cintia; Tringler, Matías; Ramírez, Agustín; Cabrera Fischer, Edmundo Ignacio
2014-01-01
In medical practice the reference values of arterial stiffness came from multicenter registries obtained in Asia, USA, Australia and Europe. Pulse wave velocity (PWV) is the gold standard method for arterial stiffness quantification; however, in South America, there are few population-based studies. In this research PWV was measured in healthy asymptomatic and normotensive subjects without history of hypertension in first-degree relatives. Normal PWV and the 95% confidence intervals values were obtained in 780 subjects (39.8 ± 18.5 years) divided into 7 age groups (10–98 years). The mean PWV found was 6.84 m/s ± 1.65. PWV increases linearly with aging with a high degree of correlation (r 2 = 0.61; P < 0.05) with low dispersion in younger subjects. PWV progressively increases 6–8% with each decade of life; this tendency is more pronounced after 50 years. A significant increase of PWV over 50 years was demonstrated. This is the first population-based study from urban and rural people of Argentina that provides normal values of the PWV in healthy, normotensive subjects without family history of hypertension. Moreover, the age dependence of PWV values was confirmed. PMID:25215227
Test of simple fluid theories for the Lennard-Jones system
NASA Astrophysics Data System (ADS)
Malijevský, A.; Labik, S.
1988-03-01
A test is made of a new version of the reference-hypernetted chain approximation (RHNC) with minimized free energy proposed by Lado, Foiles and Ashcroft. An accurate relationship is used for the bridge function of the reference hard spheres. The calculated values of the compressibility factor and the internal energy are compared with simulation data, with results of the exponential approximation of Andersen et al., and with results of the Madden-Fitts approximation. The RHNC provides the most reliable results over wide ranges of reduced temperatures and densities.
Zacharasiewicz, Angela; Renner, Sabine; Haderer, Flora; Weber, Michael; Dehlink, Eleonore; Szepfalusi, Zsolt; Frischer, Thomas
2017-08-01
Interpretation of lung function values in children with cystic fibrosis (CF) depends on the applied reference values. We hypothesize that differences between the new global lung function initiative (GLI) values and the formerly used Zapletal et al. values produce significantly different clinical results. We analyzed 3719 lung function measurements of 108 children and adolescents (n = 54 male; aged 6-18 years) with CF treated between September 1991 and July 2009. Data were analyzed in milliliters (ml) and % predicted (pred.) and interpreted using Zapletal and GLI reference values. Applying GLI compared to Zapletal resulted in significantly lower mean forced expiratory volume in 1s (FEV1)% pred. Zapletal 86.6% (SD 20.6), GLI 79.9% (SD 20.3) and 32% (n = 497/1543) were misclassified as normal when using Zapletal. Despite showing no overall differences in FEV1 and forced vital capacity (FVC) between concomitant Pseudomonas detection (PA+) in n = 938 and Pseudomonas negative (PA-) (n = 2781) using either reference PA+ resulted in lower FEV1 and FVC values with increasing age; however, measurement of small airway obstruction with forced expiratory flow at 75% of FVC (FEF75) values - available for Zapletal -showed significant differences. Reassurance regarding lung function when using old reference values may occur with potential clinical significance. Discrepancies in lung function interpretation underline the importance of using uniform and best available reference values.
Reference Values of Impulse Oscillometric Lung Function Indices in Adults of Advanced Age
Schulz, Holger; Flexeder, Claudia; Behr, Jürgen; Heier, Margit; Holle, Rolf; Huber, Rudolf M.; Jörres, Rudolf A.; Nowak, Dennis; Peters, Annette; Wichmann, H.-Erich; Heinrich, Joachim; Karrasch, Stefan
2013-01-01
Background Impulse oscillometry (IOS) is a non-demanding lung function test. Its diagnostic use may be particularly useful in patients of advanced age with physical or mental limitations unable to perform spirometry. Only few reference equations are available for Caucasians, none of them covering the old age. Here, we provide reference equations up to advanced age and compare them with currently available equations. Methods IOS was performed in a population-based sample of 1990 subjects, aged 45–91 years, from KORA cohorts (Augsburg, Germany). From those, 397 never-smoking, lung healthy subjects with normal spirometry were identified and sex-specific quantile regression models with age, height and body weight as predictors for respiratory system impedance, resistance, reactance, and other parameters of IOS applied. Results Women (n = 243) showed higher resistance values than men (n = 154), while reactance at low frequencies (up to 20 Hz) was lower (p<0.05). A significant age dependency was observed for the difference between resistance values at 5 Hz and 20 Hz (R5–R20), the integrated area of low-frequency reactance (AX), and resonant frequency (Fres) in both sexes whereas reactance at 5 Hz (X5) was age dependent only in females. In the healthy subjects (n = 397), mean differences between observed values and predictions for resistance (5 Hz and 20 Hz) and reactance (5 Hz) ranged between −1% and 5% when using the present model. In contrast, differences based on the currently applied equations (Vogel & Smidt 1994) ranged between −34% and 76%. Regarding our equations the indices were beyond the limits of normal in 8.1% to 18.6% of the entire KORA cohort (n = 1990), and in 0.7% to 9.4% with the currently applied equations. Conclusions Our study provides up-to-date reference equations for IOS in Caucasians aged 45 to 85 years. We suggest the use of the present equations particularly in advanced age in order to detect airway dysfunction. PMID:23691036
Comfort Contours: Inter-Axis Equivalence
NASA Astrophysics Data System (ADS)
Griefahn, B.; Bröde, P.
1997-07-01
Inter-axis equivalence for sinusoidal vibrations as stipulated by ISO/DIS 2631 for seated persons was studied by adjusting the acceleration of a horizontal sinusoidal test vibration (x∨y) until it caused equal sensation as a vertical sinusoidal reference motion of the same frequency. The reference vibrations consisted of sine waves ranging from 1·6 to 12·5Hz and were presented with three weighted accelerations ofazw=0·3, 0·6 and 1·2ms-2r.m.s. (reference contours). 26 subjects (15 men, 11 women, 20-55yrs, 153-187cm) participated in the respective experiments. Based on the three reference contours, predicted values for horizontal motions were calculated by using the weighting factors provided in ISO/DIS 2631. The International standard was confirmed insofar as the shape of the contours determined for horizontal motions was independent from vibration magnitudes as sensitivity to fore-and-aft and to lateral motions was similar. However, the accelerations adjusted for horizontal vibrations were considerably lower than predicted, suggesting that the weighing factors provided in ISO/DIS 2631 need to be corrected.
The new on-line Czech Food Composition Database.
Machackova, Marie; Holasova, Marie; Maskova, Eva
2013-10-01
The new on-line Czech Food Composition Database (FCDB) was launched on http://www.czfcdb.cz in December 2010 as a main freely available channel for dissemination of Czech food composition data. The application is based on a complied FCDB documented according to the EuroFIR standardised procedure for full value documentation and indexing of foods by the LanguaL™ Thesaurus. A content management system was implemented for administration of the website and performing data export (comma-separated values or EuroFIR XML transport package formats) by a compiler. Reference/s are provided for each published value with linking to available freely accessible on-line sources of data (e.g. full texts, EuroFIR Document Repository, on-line national FCDBs). LanguaL™ codes are displayed within each food record as searchable keywords of the database. A photo (or a photo gallery) is used as a visual descriptor of a food item. The application is searchable on foods, components, food groups, alphabet and a multi-field advanced search. Copyright © 2013 Elsevier Ltd. All rights reserved.
Extracting the respiration cycle lengths from ECG signal recorded with bed sheet electrodes
NASA Astrophysics Data System (ADS)
Vehkaoja, A.; Peltokangas, M.; Lekkala, J.
2013-09-01
A method for recognizing the respiration cycle lengths from the electrocardiographic (ECG) signal recorded with textile electrodes that are attached to a bed sheet is proposed. The method uses two features extracted from the ECG that are affected by the respiration: respiratory sinus arrhythmia and the amplitude of the R-peaks. The proposed method was tested in one hour long recordings with ten healthy young adults. A relative mean absolute error of 5.6 % was achieved when the algorithm was able to provide a result for approximately 40 % of the time. 90 % of the values were within 0.5 s and 97 % within 1 s from the reference respiration value. In addition to the instantaneous respiration cycle lengths, also the mean values during 1 and 5 minutes epochs are calculated. The effect of the ECG signal source is evaluated by calculating the result also from the simultaneously recorded reference ECG signal. The acquired respiration information can be used in the estimation of sleep quality and the detection of sleep disorders.
Hematologic and serum chemistry reference intervals for free-ranging lions (Panthera leo).
Maas, Miriam; Keet, Dewald F; Nielen, Mirjam
2013-08-01
Hematologic and serum chemistry values are used by veterinarians and wildlife researchers to assess health status and to identify abnormally high or low levels of a particular blood parameter in a target species. For free-ranging lions (Panthera leo) information about these values is scarce. In this study 7 hematologic and 11 serum biochemistry values were evaluated from 485 lions from the Kruger National Park, South Africa. Significant differences between sexes and sub-adult (≤ 36 months) and adult (>36 months) lions were found for most of the blood parameters and separate reference intervals were made for those values. The obtained reference intervals include the means of the various blood parameter values measured in captive lions, except for alkaline phosphatase in the subadult group. These reference intervals can be utilized for free-ranging lions, and may likely also be used as reference intervals for captive lions. Copyright © 2013 Elsevier Ltd. All rights reserved.
Improving the Glucose Meter Error Grid With the Taguchi Loss Function.
Krouwer, Jan S
2016-07-01
Glucose meters often have similar performance when compared by error grid analysis. This is one reason that other statistics such as mean absolute relative deviation (MARD) are used to further differentiate performance. The problem with MARD is that too much information is lost. But additional information is available within the A zone of an error grid by using the Taguchi loss function. Applying the Taguchi loss function gives each glucose meter difference from reference a value ranging from 0 (no error) to 1 (error reaches the A zone limit). Values are averaged over all data which provides an indication of risk of an incorrect medical decision. This allows one to differentiate glucose meter performance for the common case where meters have a high percentage of values in the A zone and no values beyond the B zone. Examples are provided using simulated data. © 2015 Diabetes Technology Society.
Reference-dependent risk sensitivity as rational inference.
Denrell, Jerker C
2015-07-01
Existing explanations of reference-dependent risk sensitivity attribute it to cognitive imperfections and heuristic choice processes. This article shows that behavior consistent with an S-shaped value function could be an implication of rational inferences about the expected values of alternatives. Theoretically, I demonstrate that even a risk-neutral Bayesian decision maker, who is uncertain about the reliability of observations, should use variability in observed outcomes as a predictor of low expected value for outcomes above a reference level, and as a predictor of high expected value for outcomes below a reference level. Empirically, I show that combining past outcomes using an S-shaped value function leads to accurate predictions about future values. The theory also offers a rationale for why risk sensitivity consistent with an inverse S-shaped value function should occur in experiments on decisions from experience with binary payoff distributions. (c) 2015 APA, all rights reserved).
Zhu, Zhi-Rong; Zeng, Chang-Chun; Yang, Li; Liu, Han-Ping; Liu, Song-Hao
2011-12-01
In this study, to analyze the influence of the brightness value of the supranasal point and the apex nasi on their dominant wavelength and excitation purity according to the spectrocolorimetry data of the supranasal point and the apex nasi in healthy adults that were collected based on optical spectrum colorimetry. A total of 516 healthy adults were taken as the research subjects. The brightness, dominant wavelength and excitation purity values of the supranasal point and the apex nasi during the complexion inspection of subjects were calculated. This was based on the visible reflection spectrum, and the linear correlation/regression analysis between the brightness Y value and the dominant wavelength or excitation purity value. There was no correlation between the brightness Y value and the dominant wavelength of the normal supranasal point and the apex nasi; however, there was negative correlation between the brightness Y value and the excitation purity of the normal supranasal point and apex nasi. During the complexion inspection, the brightness Y value would not influence the dominant wavelength value, indicating that whiteness and/or blackness would not influence the normal individual complexion. However, the brightness Y value would influence the excitation purity of the supranasal point and the apex nasi, and the degree of saturation should be referred to as the brightness. This research provides a basic reference for diagnosing facial complexion in traditional Chinese medicine.
Middleton, John; Vaks, Jeffrey E
2007-04-01
Errors of calibrator-assigned values lead to errors in the testing of patient samples. The ability to estimate the uncertainties of calibrator-assigned values and other variables minimizes errors in testing processes. International Organization of Standardization guidelines provide simple equations for the estimation of calibrator uncertainty with simple value-assignment processes, but other methods are needed to estimate uncertainty in complex processes. We estimated the assigned-value uncertainty with a Monte Carlo computer simulation of a complex value-assignment process, based on a formalized description of the process, with measurement parameters estimated experimentally. This method was applied to study uncertainty of a multilevel calibrator value assignment for a prealbumin immunoassay. The simulation results showed that the component of the uncertainty added by the process of value transfer from the reference material CRM470 to the calibrator is smaller than that of the reference material itself (<0.8% vs 3.7%). Varying the process parameters in the simulation model allowed for optimizing the process, while keeping the added uncertainty small. The patient result uncertainty caused by the calibrator uncertainty was also found to be small. This method of estimating uncertainty is a powerful tool that allows for estimation of calibrator uncertainty for optimization of various value assignment processes, with a reduced number of measurements and reagent costs, while satisfying the requirements to uncertainty. The new method expands and augments existing methods to allow estimation of uncertainty in complex processes.
Spirometric reference values for Hopi Native American children ages 4-13 years.
Arnall, David A; Nelson, Arnold G; Hearon, Christopher M; Interpreter, Christina; Kanuho, Verdell
2016-04-01
Spirometry is the most important tool in diagnosing pulmonary disease and is the most frequently performed pulmonary function test. Respiratory disease is also one of the greatest causes for morbidity and mortality on the Hopi Nation, but no specific reference equations exist for this unique population. The purpose of this study was to determine if population reference equations were necessary for these children and, if needed, to create new age and race-specific pulmonary nomograms for Hopi children. Two hundred and ninety-two healthy children, ages 4-13 years, attending Hopi Nation elementary schools in Arizona, were asked to perform spirometry for a full battery of pulmonary volumes and capacities of which the following were analyzed: forced vital capacity (FVC), forced expiratory volume in 1 sec (FEV1 ), FEV1 % (FEV1 /FVC), FEF25-75% and peak expiratory flow rate (PEFR). Spirometric data from Navajo children living in the same geographical region as the Hopi children were compared as well as spirometric data from common reference values used for other ethnic groups in the USA. Spirometry tests from 165 girls and 127 boys met American Thoracic Society quality control standards. We found that the natural log of height, body mass and age were significant predictors of FEV1 , FVC, and FEF25-75% in the gender-specific models and that lung function values all increased with height and age as expected. The predictions using the equations derived for Navajo, Caucasian, Mexican-American, African-American youth were significantly different (P ≤ 0.05) from the predictions derived from the Hopi equations for all of the variables across both genders, with the exceptions of Hopi versus Navajo FEV1 /FVC in the males and Hopi versus Caucasians FEF25-75% in the females. Thus it would appear for this population important to have specific formulae to provide more accurate reference values. © 2015 Wiley Periodicals, Inc.
Regional reference values of thyroid gland volume in Turkish Adults.
Şahin, Ertan; Elboğa, Umut; Kalender, Ebuzer
2015-01-01
It is important to know the size of the thyroid gland, and its normal value may vary among different geographic regions. In this study, we aimed to establish reference ranges for thyroid volume in euthyroid adults and to compare these results with the literature data. Between June 2011 and June 2012,461 patients with normal laboratory results (serum TSH, anti-TG, anti-TPO antibodies and urine iodine level) that underwent thyroid gland ultrasound examination were retrospectively analyzed.Two hundred and 92 patients were females and 169 were males; the age range was 18-61 years with mean age 30.84±9.97 years. Length, breadth and thickness were measured, and the volume of each lobe was estimated using the ellipsoid formula. The overall mean thyroid volume in all patients who were examined was 12.98±2.53 mL. The mean thyroid volume in females and males was 12.09±2.05 mL and 14.53±2.55, respectively (p<0.05). The right thyroid lobe volume was greater than the left in all patients of both sexes. In addition, the study establishes a significant correlation between the thyroid volume and height, weight and body surface area of the subjects of both sexes (p<0.05). In the light of our findings we can provide reference values in order to evaluate patients who have thyroid hyperplasia or who are considered as normal. We consider that further studies are necessary to establish national references thyroid volume for each country.
NASA Astrophysics Data System (ADS)
Schemel, Laurence E.; Cox, Marisa H.; Runkel, Robert L.; Kimball, Briant A.
2006-08-01
The acidic discharge from Cement Creek, containing elevated concentrations of dissolved metals and sulphate, mixed with the circumneutral-pH Animas River over a several hundred metre reach (mixing zone) near Silverton, CO, during this study. Differences in concentrations of Ca, Mg, Si, Sr, and SO42- between the creek and the river were sufficiently large for these analytes to be used as natural tracers in the mixing zone. In addition, a sodium chloride (NaCl) tracer was injected into Cement Creek, which provided a Cl- reference tracer in the mixing zone. Conservative transport of the dissolved metals and sulphate through the mixing zone was verified by mass balances and by linear mixing plots relative to the injected reference tracer. At each of seven sites in the mixing zone, five samples were collected at evenly spaced increments of the observed across-channel gradients, as determined by specific conductance. This created sets of samples that adequately covered the ranges of mixtures (mixing ratios, in terms of the fraction of Animas River water, %AR). Concentratis measured in each mixing zone sample and in the upstream Animas River and Cement Creek were used to compute %AR for the reference and natural tracers. Values of %AR from natural tracers generally showed good agreement with values from the reference tracer, but variability in discharge and end-member concentrations and analytical errors contributed to unexpected outlier values for both injected and natural tracers. The median value (MV) %AR (calculated from all of the tracers) reduced scatter in the mixing plots for the dissolved metals, indicating that the MV estimate reduced the effects of various potential errors that could affect any tracer.
1976-08-01
extensive areas of good agreement with measured loadings where the prediction is based on acoustic theory. Acoustic theory as applied to thin airfoils...Acoustic thaory ha« baen demonstrated by references 12 through 18 to provide fairly good agreeaent with measured airloads due to blast and shock... ia found to riae to large values near the leading edge. Higher observed values of Ac further rearward of the leading edge ere found to compel
Beauchet, Olivier; Allali, Gilles; Sekhon, Harmehr; Verghese, Joe; Guilain, Sylvie; Steinmetz, Jean-Paul; Kressig, Reto W.; Barden, John M.; Szturm, Tony; Launay, Cyrille P.; Grenier, Sébastien; Bherer, Louis; Liu-Ambrose, Teresa; Chester, Vicky L.; Callisaya, Michele L.; Srikanth, Velandai; Léonard, Guillaume; De Cock, Anne-Marie; Sawa, Ryuichi; Duque, Gustavo; Camicioli, Richard; Helbostad, Jorunn L.
2017-01-01
Background: Gait disorders, a highly prevalent condition in older adults, are associated with several adverse health consequences. Gait analysis allows qualitative and quantitative assessments of gait that improves the understanding of mechanisms of gait disorders and the choice of interventions. This manuscript aims (1) to give consensus guidance for clinical and spatiotemporal gait analysis based on the recorded footfalls in older adults aged 65 years and over, and (2) to provide reference values for spatiotemporal gait parameters based on the recorded footfalls in healthy older adults free of cognitive impairment and multi-morbidities. Methods: International experts working in a network of two different consortiums (i.e., Biomathics and Canadian Gait Consortium) participated in this initiative. First, they identified items of standardized information following the usual procedure of formulation of consensus findings. Second, they merged databases including spatiotemporal gait assessments with GAITRite® system and clinical information from the “Gait, cOgnitiOn & Decline” (GOOD) initiative and the Generation 100 (Gen 100) study. Only healthy—free of cognitive impairment and multi-morbidities (i.e., ≤ 3 therapeutics taken daily)—participants aged 65 and older were selected. Age, sex, body mass index, mean values, and coefficients of variation (CoV) of gait parameters were used for the analyses. Results: Standardized systematic assessment of three categories of items, which were demographics and clinical information, and gait characteristics (clinical and spatiotemporal gait analysis based on the recorded footfalls), were selected for the proposed guidelines. Two complementary sets of items were distinguished: a minimal data set and a full data set. In addition, a total of 954 participants (mean age 72.8 ± 4.8 years, 45.8% women) were recruited to establish the reference values. Performance of spatiotemporal gait parameters based on the recorded footfalls declined with increasing age (mean values and CoV) and demonstrated sex differences (mean values). Conclusions: Based on an international multicenter collaboration, we propose consensus guidelines for gait assessment and spatiotemporal gait analysis based on the recorded footfalls, and reference values for healthy older adults. PMID:28824393
Understanding and Applying the Concept of Value Creation in Radiology.
Larson, David B; Durand, Daniel J; Siegal, Daniel S
2017-04-01
The concept of value in radiology has been strongly advocated in recent years as a means of advancing patient care and decreasing waste. This article explores the concept of value creation in radiology and offers a framework for how radiology practices can create value according to the needs of their referring clinicians. Value only exists in the eyes of a customer. We propose that the primary purpose of diagnostic radiology is to answer clinical questions using medical imaging to help guide management of patient care. Because they are the direct recipient of this service, we propose that referring clinicians are the direct customers of a radiology practice and patients are indirect customers. Radiology practices create value as they understand and fulfill their referring clinicians' needs. To narrow those needs to actionable categories, we propose a framework consisting of four major dimensions: (1) how quickly the clinical question needs to be answered, (2) the degree of specialization required to answer the question, (3) how often the referring clinician uses imaging, and (4) the breadth of imaging that the referring clinician uses. We further identify three major settings in which referring clinicians utilize radiological services: (1) emergent or urgent care, (2) primary care, and (3) specialty care. Practices best meet these needs as they engage with their referring clinicians, create a shared vision, work together as a cohesive team, structure the organization to meet referring clinicians' needs, build the tools, and continually improve in ways that help referring clinicians care for patients. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Imboden, Mary T.; Swartz, Ann M.; Finch, Holmes W.; Harber, Matthew P.; Kaminsky, Leonard A.
2017-01-01
Body composition assessments commonly focus predominantly on fat mass, however lean mass (LM) measurements also provide useful information regarding clinical and nutritional status. LM measurements help predict health outcomes and diagnose sarcopenia, which has been associated with frailty. Dual energy x-ray absorptiometry (DXA) is an established technique used in clinical and research settings to assess body composition including total and regional LM. Currently, there are no reference values available that were derived from GE-Healthcare DXA systems directly for US adults for LM, LM index (LMI), percent LM (%LM), and appendicular lean mass index (ALMI) and it is known that whole-body and regional LM measures differ by DXA manufacturer. Objective To develop reference values by age and sex for LM measures using GE-Healthcare DXA systems. Methods A de-identified sample was obtained from Ball State University’s Clinical Exercise Physiology Laboratory and University of Wisconsin-Milwaukee’s Physical Activity & Health Research Laboratory. DXA scans of 2,076 women and 1,251 men were completed using a GE Lunar Prodigy or iDXA. Percentiles (%ile) were calculated for all variables of interest (LM, LMI, %LM, and ALMI) and a factorial ANOVA was used to assess differences for each variable between 10-year age groups and sex, as well as the interaction between age and sex. Results Men had higher mean total LM, %LM, LMI, and ALMI than women (p<0.01), across all age groups. All LM variables decreased significantly over the 5 decades in men, however in women only total LM, %LM, and ALMI decreased from the youngest to oldest age groups (p<0.01). Conclusion These reference values provide for a more accurate interpretation of GE-Healthcare DXA-derived LM measurements offering clinicians and researchers with an initial resource to aid in the early detection and assessment of LM deficits. PMID:28426779
Orbital Signature Analyzer (OSA): A spacecraft health/safety monitoring and analysis tool
NASA Technical Reports Server (NTRS)
Weaver, Steven; Degeorges, Charles; Bush, Joy; Shendock, Robert; Mandl, Daniel
1993-01-01
Fixed or static limit sensing is employed in control centers to ensure that spacecraft parameters remain within a nominal range. However, many critical parameters, such as power system telemetry, are time-varying and, as such, their 'nominal' range is necessarily time-varying as well. Predicted data, manual limits checking, and widened limit-checking ranges are often employed in an attempt to monitor these parameters without generating excessive limits violations. Generating predicted data and manual limits checking are both resource intensive, while broadening limit ranges for time-varying parameters is clearly inadequate to detect all but catastrophic problems. OSA provides a low-cost solution by using analytically selected data as a reference upon which to base its limits. These limits are always defined relative to the time-varying reference data, rather than as fixed upper and lower limits. In effect, OSA provides individual limits tailored to each value throughout all the data. A side benefit of using relative limits is that they automatically adjust to new reference data. In addition, OSA provides a wealth of analytical by-products in its execution.
Latorre Román, Pedro Ángel; López, David Mora; Aguayo, Beatriz Berrios; Fuentes, Alejandro Robles; García-Pinillos, Felipe; Redondo, Melchor Martínez
2017-07-01
The purpose of this study was to examine the influence of age, sex and anthropometric variables in handgrip strength and to determine norm-referenced values for preschool children. Cross-sectional study. Schools. A total of 1215 children, aged 3-6 years (590 girls and 625 boys). Not applicable. Handgrip strength (HS), measured by the CAMRY hydraulic hand dynamometer (EH101; Camry, Guangdong Province, China). Boys exhibited a greater performance than girls in the 4 and 5 years age groups, but no significant differences were found at 3 and 6 years. In relation to growth, HS performance was greater with increased age. The Pearson correlation analysis showed significant correlations between HS and body mass (r = 0.354, p < 0.001), body height (r = 0.352, p < 0.001), body mass index (r = 0.164, p < 0.001) and waist circumference (r = 0.118, p < 0.001). This study provides references values for muscular strength assessment by an HS test carried out on a large sample of preschoolers in relation to age and sex. Additionally, some differences in HS performance were found according to sex. Copyright © 2017 Elsevier Ltd. All rights reserved.
Reference values for 34 frequently used laboratory tests in 80-year-old men and women.
Helmersson-Karlqvist, Johanna; Ridefelt, Peter; Lind, Lars; Larsson, Anders
2016-10-01
Reference values are usually based on blood samples from healthy individuals in the age range 20-50 years. Most patients seeking health care are older than this reference population. Many reference intervals are age dependent and there is thus a need to have appropriate reference intervals also for elderly individuals. We analyzed a group of frequently used laboratory tests in an 80-year-old population (n=531, 266 females and 265 males). The 2.5th and 97.5th percentiles for these markers were calculated according to the International Federation of Clinical Chemistry guidelines on the statistical treatment of reference values. Reference values are reported for serum alanine transaminase (ALT), albumin, alkaline phosphatase, pancreatic amylase, apolipoprotein A1, apolipoprotein B, apolipoprotein B/apolipoprotein A1 ratio, aspartate aminotransferase (AST), AST/ALT ratio, bilirubin, calcium, calprotectin, cholesterol, HDL-cholesterol, creatinine kinase (CK), creatinine, creatinine estimated GFR, C-reactive protein, cystatin C, cystatin C estimated GFR, gamma-glutamyltransferase (GGT), iron, iron saturation, lactate dehydrogenase (LDH), magnesium, phosphate, transferrin, triglycerides, urate, urea, zinc, hemoglobin, platelet count and white blood cell count. The upper reference limit for creatinine and urea was significantly increased while the lower limit for iron and albumin was decreased in this elderly population in comparison with the population in the Nordic Reference Interval Project (NORIP). Reference values calculated from the whole population and a subpopulation without cardiovascular disease showed strong concordance. Several of the reference interval limits were outside the 90% confidence interval of NORIP. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Shah, Amish P.
The need for improved patient-specificity of skeletal dose estimates is widely recognized in radionuclide therapy. Current clinical models for marrow dose are based on skeletal mass estimates from a variety of sources and linear chord-length distributions that do not account for particle escape into cortical bone. To predict marrow dose, these clinical models use a scheme that requires separate calculations of cumulated activity and radionuclide S values. Selection of an appropriate S value is generally limited to one of only three sources, all of which use as input the trabecular microstructure of an individual measured 25 years ago, and the tissue mass derived from different individuals measured 75 years ago. Our study proposed a new modeling approach to marrow dosimetry---the Paired Image Radiation Transport (PIRT) model---that properly accounts for both the trabecular microstructure and the cortical macrostructure of each skeletal site in a reference male radionuclide patient. The PIRT model, as applied within EGSnrc, requires two sets of input geometry: (1) an infinite voxel array of segmented microimages of the spongiosa acquired via microCT; and (2) a segmented ex-vivo CT image of the bone site macrostructure defining both the spongiosa (marrow, endosteum, and trabeculae) and the cortical bone cortex. Our study also proposed revising reference skeletal dosimetry models for the adult male cancer patient. Skeletal site-specific radionuclide S values were obtained for a 66-year-old male reference patient. The derivation for total skeletal S values were unique in that the necessary skeletal mass and electron dosimetry calculations were formulated from the same source bone site over the entire skeleton. We conclude that paired-image radiation-transport techniques provide an adoptable method by which the intricate, anisotropic trabecular microstructure of the skeletal site; and the physical size and shape of the bone can be handled together, for improved compilation of reference radionuclide S values. We also conclude that this comprehensive model for the adult male cancer patient should be implemented for use in patient-specific calculations for radionuclide dosimetry of the skeleton.
Recommended Screening Practices for Launch Collision Aviodance
NASA Technical Reports Server (NTRS)
Beaver, Brian A.; Hametz, Mark E.; Ollivierre, Jarmaine C.; Newman, Lauri K.; Hejduk, Matthew D.
2015-01-01
The objective of this document is to assess the value of launch collision avoidance (COLA) practices and provide recommendations regarding its implementation for NASA robotic missions. The scope of this effort is limited to launch COLA screens against catalog objects that are either spacecraft or debris. No modifications to manned safety COLA practices are considered in this effort. An assessment of the value of launch COLA can be broken down into two fundamental questions: 1) Does collision during launch represent a significant risk to either the payload being launched or the space environment? 2) Can launch collision mitigation be performed in a manner that provides meaningful risk reduction at an acceptable level of operational impact? While it has been possible to piece together partial answers to these questions for some time, the first attempt to comprehensively address them is documented in reference (a), Launch COLA Operations: an Examination of Data Products, Procedures, and Thresholds, Revision A. This report is the product of an extensive study that addressed fundamental technical questions surrounding launch collision avoidance analysis and practice. The results provided in reference (a) will be cited throughout this document as these two questions are addressed. The premise of this assessment is that in order to conclude that launch COLA is a value-added activity, the answer to both of these questions must be affirmative. A "no" answer to either of these questions points toward the conclusion that launch COLA provides little or no risk mitigation benefit. The remainder of this assessment will focus on addressing these two questions.
Reiner, Jessica L; O'Connell, Steven G; Butt, Craig M; Mabury, Scott A; Small, Jeff M; De Silva, Amila O; Muir, Derek C G; Delinsky, Amy D; Strynar, Mark J; Lindstrom, Andrew B; Reagen, William K; Malinsky, Michelle; Schäfer, Sandra; Kwadijk, Christiaan J A F; Schantz, Michele M; Keller, Jennifer M
2012-11-01
Standard reference materials (SRMs) are homogeneous, well-characterized materials used to validate measurements and improve the quality of analytical data. The National Institute of Standards and Technology (NIST) has a wide range of SRMs that have mass fraction values assigned for legacy pollutants. These SRMs can also serve as test materials for method development, method validation, and measurement for contaminants of emerging concern. Because inter-laboratory comparison studies have revealed substantial variability of measurements of perfluoroalkyl acids (PFAAs), future analytical measurements will benefit from determination of consensus values for PFAAs in SRMs to provide a means to demonstrate method-specific performance. To that end, NIST, in collaboration with other groups, has been measuring concentrations of PFAAs in a variety of SRMs. Here we report levels of PFAAs and perfluorooctane sulfonamide (PFOSA) determined in four biological SRMs: fish tissue (SRM 1946 Lake Superior Fish Tissue, SRM 1947 Lake Michigan Fish Tissue), bovine liver (SRM 1577c), and mussel tissue (SRM 2974a). We also report concentrations for three in-house quality-control materials: beluga whale liver, pygmy sperm whale liver, and white-sided dolphin liver. Measurements in SRMs show an array of PFAAs, with perfluorooctane sulfonate (PFOS) being the most frequently detected. Reference and information values are reported for PFAAs measured in these biological SRMs.
NASA Astrophysics Data System (ADS)
Wang, Qian; Gao, Jinghuai
2018-02-01
As a powerful tool for hydrocarbon detection and reservoir characterization, the quality factor, Q, provides useful information in seismic data processing and interpretation. In this paper, we propose a novel method for Q estimation. The generalized seismic wavelet (GSW) function was introduced to fit the amplitude spectrum of seismic waveforms with two parameters: fractional value and reference frequency. Then we derive an analytical relation between the GSW function and the Q factor of the medium. When a seismic wave propagates through a viscoelastic medium, the GSW function can be employed to fit the amplitude spectrum of the source and attenuated wavelets, then the fractional values and reference frequencies can be evaluated numerically from the discrete Fourier spectrum. After calculating the peak frequency based on the obtained fractional value and reference frequency, the relationship between the GSW function and the Q factor can be built by the conventional peak frequency shift method. Synthetic tests indicate that our method can achieve higher accuracy and be more robust to random noise compared with existing methods. Furthermore, the proposed method is applicable to different types of source wavelet. Field data application also demonstrates the effectiveness of our method in seismic attenuation and the potential in the reservoir characteristic.
Keller, Jennifer M; Calafat, Antonia M; Kato, Kayoko; Ellefson, Mark E; Reagen, William K; Strynar, Mark; O'Connell, Steven; Butt, Craig M; Mabury, Scott A; Small, Jeff; Muir, Derek C G; Leigh, Stefan D; Schantz, Michele M
2010-05-01
Standard Reference Materials (SRMs) are certified reference materials produced by the National Institute of Standards and Technology that are homogeneous materials well characterized with values for specified properties, such as environmental contaminant concentrations. They can be used to validate measurement methods and are critical in improving data quality. Disagreements in perfluorinated alkyl acid (PFAA) concentrations measured in environmental matrices during past interlaboratory comparisons emphasized the need for SRMs with values assigned for PFAAs. We performed a new interlaboratory comparison among six laboratories and provided, for the first time, value assignment of PFAAs in SRMs. Concentrations for perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), and other PFAAs in two human serum and two human milk SRMs are reported. PFAA concentration measurements agreed for serum SRM 1957 using different analytical methods in six laboratories and for milk SRM 1954 in three laboratories. The interlaboratory relative standard deviation for PFOS in SRM 1957 was 7%, which is an improvement over past interlaboratory studies. Matrix interferences are discussed, as well as temporal trends and the percentage of branched vs. linear isomers. The concentrations in these SRMs are similar to the present-day average concentrations measured in human serum and milk, resulting in representative and useful control materials for PFAA human monitoring studies.
Growth status and estimated growth rate of youth football players: a community-based study.
Malina, Robert M; Morano, Peter J; Barron, Mary; Miller, Susan J; Cumming, Sean P
2005-05-01
To characterize the growth status of participants in community-sponsored youth football programs and to estimate rates of growth in height and weight. Mixed-longitudinal over 2 seasons. Two communities in central Michigan. Members of 33 youth football teams in 2 central Michigan communities in the 2000 and 2001 seasons (Mid-Michigan PONY Football League). Height and weight of all participants were measured prior to each season, 327 in 2000 and 326 in 2001 (n = 653). The body mass index (kg/m) was calculated. Heights and weights did not differ from season to season and between the communities; the data were pooled and treated cross-sectionally. Increments of growth in height and weight were estimated for 166 boys with 2 measurements approximately 1 year apart to provide an estimate of growth rate. Growth status (size-attained) of youth football players relative to reference data (CDC) for American boys and estimated growth rate relative to reference values from 2 longitudinal studies of American boys. Median heights of youth football players approximate the 75th percentiles, while median weights approximate the 75th percentiles through 11 years and then drift toward the 90th percentiles of the reference. Median body mass indexes of youth football players fluctuate about the 85th percentiles of the reference. Estimated growth rates in height approximate the reference and may suggest earlier maturation, while estimated growth rates in weight exceed the reference. Youth football players are taller and especially heavier than reference values for American boys. Estimated rates of growth in height approximate medians for American boys and suggest earlier maturation. Estimated rates of growth in weight exceed those of the reference and may place many youth football players at risk for overweight/obesity, which in turn may be a risk factor for injury.
Xiao, J; Purcell, S A; Prado, C M; Gonzalez, M C
2017-10-06
Low fat-free mass (FFM) or high fat mass (FM) are abnormal body composition phenotypes associated with morbidity. These conditions in combination lead to worse health outcomes, and can be identified by a high FM/FFM ratio. Here, we developed sex, age, and body mass index (BMI) stratified, population-based FM/FFM reference values using bioelectrical impedance analysis (BIA) measurements. White, non-Hispanic individuals aged 18-90 years old with data for weight, stature and BIA resistance measures from the third National Health and Nutrition Examination Survey (NHANES) III were included. Previously validated and sex-specific BIA prediction equations were used to calculate FM and FFM. FM/FFM values were generated at 5th, 50th and 95th percentiles for each sex, age (18-39.9, 40-59.9, 60-69.9 and 70-90 years), and BMI category (underweight, normal weight, overweight, class I/II and class III obesity). A total of 6372 individuals who had estimated FM and FFM values were identified (3366 females, 3006 males). Median values of FM/FFM were 0.24 and 0.40 for young (≤39.9 years) males and females with normal BMI, and 0.34 for males and 0.59 for females who were overweight. For elderly individuals aged >70 years, median FM/FFM for males and females were respectively 0.28 and 0.45 for those with normal BMI, and 0.37 and 0.61 for those in the overweight category. These FM/FFM reference values provide information on body composition characteristics that account for age, sex and BMI, which can be useful to identify individuals at risk for body composition abnormalities. Copyright © 2017 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Standard reference water samples for rare earth element determinations
Verplanck, P.L.; Antweiler, Ronald C.; Nordstrom, D. Kirk; Taylor, Howard E.
2001-01-01
Standard reference water samples (SRWS) were collected from two mine sites, one near Ophir, CO, USA and the other near Redding, CA, USA. The samples were filtered, preserved, and analyzed for rare earth element (REE) concentrations (La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, and Lu) by inductively coupled plasma-mass spectrometry (ICP-MS). These two samples were acid mine waters with elevated concentrations of REEs (0.45-161 ??g/1). Seventeen international laboratories participated in a 'round-robin' chemical analysis program, which made it possible to evaluate the data by robust statistical procedures that are insensitive to outliers. The resulting most probable values are reported. Ten to 15 of the participants also reported values for Ba, Y, and Sc. Field parameters, major ion, and other trace element concentrations, not subject to statistical evaluation, are provided.
Zeleny, Reinhard; Nia, Yacine; Schimmel, Heinz; Mutel, Isabelle; Hennekinne, Jacques-Antoine; Emteborg, Håkan; Charoud-Got, Jean; Auvray, Frédéric
2016-08-01
Staphylococcal enterotoxins (SEs) account for a substantial number of food-poisoning outbreaks. European legislation (Commission Regulation 1441/2007) stipulates the reference procedure for SE analysis in milk and dairy products, which is based on extraction, dialysis concentration and immunochemical detection using one of two approved assays (VIDAS(®) SET2, Ridascreen(®) SET Total). However, certified reference materials (CRMs) are lacking to support laboratories in performing reliable detection of Staphylococcus aureus enterotoxin A (SEA) in relevant matrices at sub-nanogram per gram levels. The certification of a set of three reference materials (blank and two SEA-containing materials) for testing of the presence/absence of SEA in cheese is described. The reference procedure was applied in an intercomparison with 15 laboratories, and results were reported in a qualitative manner (presence or absence of SEA in the sample). No false-negative or false-positive results were obtained. The certified values were stated as diagnostic specificity (blank material) or diagnostic sensitivity (SEA-containing materials) and were 100 % in all cases. Stability studies demonstrated suitable material stability when stored cooled or frozen. An in-house study on the recovery of SEA in the cheese materials using a double-sandwich enzyme-linked immunosorbent assay (ELISA) revealed comparable recovery values of around 45 % at the two spiking levels and in both the SEA-containing CRMs as well as blank CRM freshly spiked prior to analysis. The values were also comparable over time and among different analysts. The materials provide valuable support to laboratories for method validation and method performance verification and will increase the reliability of measuring SEA in cheese.
Physical fitness reference standards in European children: the IDEFICS study.
De Miguel-Etayo, P; Gracia-Marco, L; Ortega, F B; Intemann, T; Foraita, R; Lissner, L; Oja, L; Barba, G; Michels, N; Tornaritis, M; Molnár, D; Pitsiladis, Y; Ahrens, W; Moreno, L A
2014-09-01
A low fitness status during childhood and adolescence is associated with important health-related outcomes, such as increased future risk for obesity and cardiovascular diseases, impaired skeletal health, reduced quality of life and poor mental health. Fitness reference values for adolescents from different countries have been published, but there is a scarcity of reference values for pre-pubertal children in Europe, using harmonised measures of fitness in the literature. The IDEFICS study offers a good opportunity to establish normative values of a large set of fitness components from eight European countries using common and well-standardised methods in a large sample of children. Therefore, the aim of this study is to report sex- and age-specific fitness reference standards in European children. Children (10,302) aged 6-10.9 years (50.7% girls) were examined. The test battery included: the flamingo balance test, back-saver sit-and-reach test (flexibility), handgrip strength test, standing long jump test (lower-limb explosive strength) and 40-m sprint test (speed). Moreover, cardiorespiratory fitness was assessed by a 20-m shuttle run test. Percentile curves for the 1st, 3rd, 10th, 25th, 50th, 75th, 90th, 97th and 99th percentiles were calculated using the General Additive Model for Location Scale and Shape (GAMLSS). Our results show that boys performed better than girls in speed, lower- and upper-limb strength and cardiorespiratory fitness, and girls performed better in balance and flexibility. Older children performed better than younger children, except for cardiorespiratory fitness in boys and flexibility in girls. Our results provide for the first time sex- and age-specific physical fitness reference standards in European children aged 6-10.9 years.
Pearman, Timothy; Yanez, Betina; Peipert, John; Wortman, Katy; Beaumont, Jennifer; Cella, David
2014-09-15
Health-related quality of life (HRQOL) measures are commonly used in oncology research. Interest in their use for monitoring or screening is increasing. The Functional Assessment of Cancer Therapy (FACT) is one of the most widely used HRQOL instruments. Consequently, oncology researchers and practitioners have an increasing need for reference values for the Functional Assessment of Cancer Therapy-General (FACT-G) and its 7-item rapid version, the Functional Assessment of Cancer Therapy-General 7 (FACT-G7), to compare FACT scores across specific subgroups of patients in research trials and practice. The objectives of this study are to provide 1) reference values from a sample of the general US adult population and a sample of adults diagnosed with cancer and 2) cutoff scores for quality of life. A sample of the general US population (N = 1075) and a sample of patients with cancer from 12 studies (N = 5065) were analyzed. Cutoff scores were established using distribution- and anchor-based methods. Mean values for the cancer sample were analyzed by performance status, cancer type, and disease status. Also, t tests and established criteria for meaningful differences were used to compare values. FACT-G and FACT-G7 scores in the general US population sample and cancer sample were generally comparable. Among the sample of patients with cancer, FACT-G and FACT-G7 scores worsened with declining performance status and increasing disease status. These data will aid interpretation of the magnitude and meaning of FACT scores, and allow for comparisons of scores across studies. © 2014 American Cancer Society.
NASA Astrophysics Data System (ADS)
Widlowski, J.-L.; Pinty, B.; Lopatka, M.; Atzberger, C.; Buzica, D.; Chelle, M.; Disney, M.; Gastellu-Etchegorry, J.-P.; Gerboles, M.; Gobron, N.; Grau, E.; Huang, H.; Kallel, A.; Kobayashi, H.; Lewis, P. E.; Qin, W.; Schlerf, M.; Stuckens, J.; Xie, D.
2013-07-01
The radiation transfer model intercomparison (RAMI) activity aims at assessing the reliability of physics-based radiative transfer (RT) models under controlled experimental conditions. RAMI focuses on computer simulation models that mimic the interactions of radiation with plant canopies. These models are increasingly used in the development of satellite retrieval algorithms for terrestrial essential climate variables (ECVs). Rather than applying ad hoc performance metrics, RAMI-IV makes use of existing ISO standards to enhance the rigor of its protocols evaluating the quality of RT models. ISO-13528 was developed "to determine the performance of individual laboratories for specific tests or measurements." More specifically, it aims to guarantee that measurement results fall within specified tolerance criteria from a known reference. Of particular interest to RAMI is that ISO-13528 provides guidelines for comparisons where the true value of the target quantity is unknown. In those cases, "truth" must be replaced by a reliable "conventional reference value" to enable absolute performance tests. This contribution will show, for the first time, how the ISO-13528 standard developed by the chemical and physical measurement communities can be applied to proficiency testing of computer simulation models. Step by step, the pre-screening of data, the identification of reference solutions, and the choice of proficiency statistics will be discussed and illustrated with simulation results from the RAMI-IV "abstract canopy" scenarios. Detailed performance statistics of the participating RT models will be provided and the role of the accuracy of the reference solutions as well as the choice of the tolerance criteria will be highlighted.
Zhang, Gao-Ming; Guo, Xu-Xiao; Ma, Xiao-Bo; Zhang, Guo-Ming
2016-12-12
BACKGROUND The aim of this study was to calculate 95% reference intervals and double-sided limits of serum alpha-fetoprotein (AFP) and carcinoembryonic antigen (CEA) according to the CLSI EP28-A3 guideline. MATERIAL AND METHODS Serum AFP and CEA values were measured in samples from 26 000 healthy subjects in the Shuyang area receiving general health checkups. The 95% reference intervals and upper limits were calculated by using MedCalc. RESULTS We provided continuous reference intervals from 20 years old to 90 years old for AFP and CEA. The reference intervals were: AFP, 1.31-7.89 ng/ml (males) and 1.01-7.10 ng/ml (females); CEA, 0.51-4.86 ng/ml (males) and 0.35-3.45ng/ml (females). AFP and CEA were significantly positively correlated with age in both males (r=0.196 and r=0.198) and females (r=0.121 and r=0.197). CONCLUSIONS Different races or populations and different detection systems may result in different reference intervals for AFP and CEA. Continuous reference intervals of age changes are more accurate than age groups.
Life after Shakespeare: Careers for Liberal Arts Majors.
ERIC Educational Resources Information Center
Flores-Esteves, Manuel
Career briefs on 30 fields that liberal arts graduates might pursue are provided, and the value of a liberal arts degree to job applicants is addressed. Included are published reference sources; information on job search skills, writing a resume, and interviewing techniques; and advice on finding a challenging internship. For each field,…
47 CFR 73.184 - Groundwave field strength graphs.
Code of Federal Regulations, 2011 CFR
2011-10-01
... a dielectric constant of the ground (referred to air as unity) equal to 15 for land and 80 for sea..., Washington, DC 20554, (202) 632-7000. (c) Provided the value of the dielectric constant is near 15, the... dielectric constant, the following procedure may be used to determine the dielectric constant of the ground...
USDA-ARS?s Scientific Manuscript database
Evapotranspiration estimates for scheduling irrigation must be field specific and real time. Weather station networks provide daily reference ET values, but users need to select crop coefficients for their particular crop and field. A prototype system has been developed that combines satellite image...
C-statistic fitting routines: User's manual and reference guide
NASA Technical Reports Server (NTRS)
Nousek, John A.; Farwana, Vida
1991-01-01
The computer program is discussed which can read several input files and provide a best set of values for the functions provided by the user, using either C-statistic or the chi(exp 2) statistic method. The program consists of one main routine and several functions and subroutines. Detail descriptions of each function and subroutine is presented. A brief description of the C-statistic and the reason for its application is also presented.
[Clinical value evaluation of Chinese herbal formula in context of multi-omics network].
Li, Bing; Han, Fei; Wang, Zhong; Wang, Yong-Yan
2017-03-01
Clinical value evaluation is the key issue to solve the problems such as high repetition rate, fuzzy clinical positioning, broad indications and unclear clinical values in Chinese herbal formula(Chinese patent medicine). By analyzing the challenges and opportunities of Chinese herbal formula in clinical value evaluation, this paper introduced a strategy of multi-omic network analysis. Through comparative analysis of three stroke treatment formulas, we suggested their different characteristic advantages for variant symptoms or phenotypes of stroke, which may provide reference for rational clinical choice. Such multi-omic network analysis strategy may open a unique angle of view for clinical evaluation and comparison of Chinese herbal formula. Copyright© by the Chinese Pharmaceutical Association.
Geochemical Data Package for Performance Assessment Calculations Related to the Savannah River Site
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaplan, Daniel I.
The Savannah River Site (SRS) disposes of low-level radioactive waste (LLW) and stabilizes high-level radioactive waste (HLW) tanks in the subsurface environment. Calculations used to establish the radiological limits of these facilities are referred to as Performance Assessments (PA), Special Analyses (SA), and Composite Analyses (CA). The objective of this document is to revise existing geochemical input values used for these calculations. This work builds on earlier compilations of geochemical data (2007, 2010), referred to a geochemical data packages. This work is being conducted as part of the on-going maintenance program of the SRS PA programs that periodically updates calculationsmore » and data packages when new information becomes available. Because application of values without full understanding of their original purpose may lead to misuse, this document also provides the geochemical conceptual model, the approach used for selecting the values, the justification for selecting data, and the assumptions made to assure that the conceptual and numerical geochemical models are reasonably conservative (i.e., bias the recommended input values to reflect conditions that will tend to predict the maximum risk to the hypothetical recipient). This document provides 1088 input parameters for geochemical parameters describing transport processes for 64 elements (>740 radioisotopes) potentially occurring within eight subsurface disposal or tank closure areas: Slit Trenches (ST), Engineered Trenches (ET), Low Activity Waste Vault (LAWV), Intermediate Level (ILV) Vaults, Naval Reactor Component Disposal Areas (NRCDA), Components-in-Grout (CIG) Trenches, Saltstone Facility, and Closed Liquid Waste Tanks. The geochemical parameters described here are the distribution coefficient, Kd value, apparent solubility concentration, k s value, and the cementitious leachate impact factor.« less
Trial-Type Dependent Frames of Reference for Value Comparison
Hunt, Laurence T.; Woolrich, Mark W.; Rushworth, Matthew F. S.; Behrens, Timothy E. J.
2013-01-01
A central question in cognitive neuroscience regards the means by which options are compared and decisions are resolved during value-guided choice. It is clear that several component processes are needed; these include identifying options, a value-based comparison, and implementation of actions to execute the decision. What is less clear is the temporal precedence and functional organisation of these component processes in the brain. Competing models of decision making have proposed that value comparison may occur in the space of alternative actions, or in the space of abstract goods. We hypothesized that the signals observed might in fact depend upon the framing of the decision. We recorded magnetoencephalographic data from humans performing value-guided choices in which two closely related trial types were interleaved. In the first trial type, each option was revealed separately, potentially causing subjects to estimate each action's value as it was revealed and perform comparison in action-space. In the second trial type, both options were presented simultaneously, potentially leading to comparison in abstract goods-space prior to commitment to a specific action. Distinct activity patterns (in distinct brain regions) on the two trial types demonstrated that the observed frame of reference used for decision making indeed differed, despite the information presented being formally identical, between the two trial types. This provides a potential reconciliation of conflicting accounts of value-guided choice. PMID:24068906
What Is the Reference? An Examination of Alternatives to the Reference Sources Used in IES TM-30-15
DOE Office of Scientific and Technical Information (OSTI.GOV)
Royer, Michael P.
A study was undertaken to document the role of the reference illuminant in the IES TM-30-15 method for evaluating color rendition. TM-30-15 relies on a relative reference scheme; that is, the reference illuminant and test source always have the same correlated color temperature (CCT). The reference illuminant is a Planckian radiator, model of daylight, or combination of those two, depending on the exact CCT of the test source. Three alternative reference schemes were considered: 1) either using all Planckian radiators or all daylight models; 2) using only one of ten possible illuminants (Planckian, daylight, or equal energy), regardless of themore » CCT of the test source; 3) using an off-Planckian reference illuminant (i.e., a source with a negative Duv). No reference scheme is inherently superior to another, with differences in metric values largely a result of small differences in gamut shape of the reference alternatives. While using any of the alternative schemes is more reasonable in the TM-30-15 evaluation framework than it was with the CIE CRI framework, the differences still ultimately manifest only as changes in interpretation of the results. References are employed in color rendering measures to provide a familiar point of comparison, not to establish an ideal source.« less
Máximo, Wesley P. F.; Zanetti, Ronald; Paiva, Luciano V.
2018-01-01
Although several ant species are important targets for the development of molecular control strategies, only a few studies focus on identifying and validating reference genes for quantitative reverse transcription polymerase chain reaction (RT-qPCR) data normalization. We provide here an extensive study to identify and validate suitable reference genes for gene expression analysis in the ant Atta sexdens, a threatening agricultural pest in South America. The optimal number of reference genes varies according to each sample and the result generated by RefFinder differed about which is the most suitable reference gene. Results suggest that the RPS16, NADH and SDHB genes were the best reference genes in the sample pool according to stability values. The SNF7 gene expression pattern was stable in all evaluated sample set. In contrast, when using less stable reference genes for normalization a large variability in SNF7 gene expression was recorded. There is no universal reference gene suitable for all conditions under analysis, since these genes can also participate in different cellular functions, thus requiring a systematic validation of possible reference genes for each specific condition. The choice of reference genes on SNF7 gene normalization confirmed that unstable reference genes might drastically change the expression profile analysis of target candidate genes. PMID:29419794
Permeability of soils in Mississippi
O'Hara, Charles G.
1994-01-01
The permeability of soils in Mississippi was determined and mapped using a geographic information system (GIS). Soil permeabilities in Mississippi were determined to range in value from nearly 0.0 to values exceeding 5.0 inches per hour. The U.S. Soil Conservation Service's State Soil Geographic Data Base (STATSGO) was used as the primary source of data for the determination of area-weighted soil permeability. STATSGO provides soil layer properties that are spatially referenced to mapped areas. These mapped areas are referred to as polygons in the GIS. The polygons arc boundaries of soils mapped as a group and are given unique Map Unit Identifiers (MUIDs). The data describing the physical characteristics of the soils within each polygon are stored in a tabular data base format and are referred to as attributes. The U.S. Soil Conservation Service developed STATSGO to be primarily used as a guide for regional resource planning, management, and monitoring. STATSGO was designed so that soil information could be extracted from properties tables at the layer level, combined by component, and statistically expanded to cover the entire map unit. The results of this study provide a mapped value for permeability which is representative of the vertical permeability of soils in that area. The resultant permeability map provides a representative vertical soil permeability for a given area sufficient for county, multi- county, and area planning, and will be used as the soil permeability data component in the evaluation of the susceptibility of major aquifers to contami- nation in Mississippi.
Update on value-based medicine.
Brown, Melissa M; Brown, Gary C
2013-05-01
To update concepts in Value-Based Medicine, especially in view of the Patient Protection and Affordable Care Act. The Patient Protection and Affordable Care Act assures that some variant of Value-Based Medicine cost-utility analysis will play a key role in the healthcare system. It identifies the highest quality care, thereby maximizing the most efficacious use of healthcare resources and empowering patients and physicians.Standardization is critical for the creation and acceptance of a Value-Based Medicine, cost-utility analysis, information system, since 27 million different input variants can go into a cost-utility analysis. Key among such standards is the use of patient preferences (utilities), as patients best understand the quality of life associated with their health states. The inclusion of societal costs, versus direct medical costs alone, demonstrates that medical interventions are more cost effective and, in many instances, provide a net financial return-on-investment to society referent to the direct medical costs expended. Value-Based Medicine provides a standardized methodology, integrating critical, patient, quality-of-life preferences, and societal costs, to allow the highest quality, most cost-effective care. Central to Value-Based Medicine is the concept that all patients deserve the interventions that provide the greatest patient value (improvement in quality of life and/or length of life).
An Impedance-Based Mold Sensor with on-Chip Optical Reference
Papireddy Vinayaka, Poornachandra; van den Driesche, Sander; Blank, Roland; Tahir, Muhammad Waseem; Frodl, Mathias; Lang, Walter; Vellekoop, Michael J.
2016-01-01
A new miniaturized sensor system with an internal optical reference for the detection of mold growth is presented. The sensor chip comprises a reaction chamber provided with a culture medium that promotes the growth of mold species from mold spores. The mold detection is performed by measuring impedance changes with integrated electrodes fabricated inside the reaction chamber. The impedance change in the culture medium is caused by shifts in the pH (i.e., from 5.5 to 8) as the mold grows. In order to determine the absolute pH value without the need for calibration, a methyl red indicator dye has been added to the culture medium. It changes the color of the medium as the pH passes specific values. This colorimetric principle now acts as a reference measurement. It also allows the sensitivity of the impedance sensor to be established in terms of impedance change per pH unit. Major mold species that are involved in the contamination of food, paper and indoor environments, like Fusarium oxysporum, Fusarium incarnatum, Eurotium amstelodami, Aspergillus penicillioides and Aspergillus restrictus, have been successfully analyzed on-chip. PMID:27690039
Oh, Hea Lin; Lee, Jun Ah; Kim, Dong Ho; Lim, Jung Sub
2018-03-01
Ferritin reference values vary by age, gender, and ethnicity. We aimed to determine reference values of serum ferritin (SF) and the percentage of transferrin saturation (TSAT) for Korean children and adolescents. We analyzed data from 2,487 participants (1,311 males and 1,176 females) aged 10-20 years from the Korea National Health and Nutrition Examination Survey (2010-2012). We calculated age- and gender-stratified means and percentile values for SF and TSAT. We first plotted mean SF and TSAT by gender and according to age. In males, mean SF tended to be relatively constant among participants aged 10 to 14 years, with an upward trend thereafter. Mean SF trended downward among female participants until the age of 15 years and remained constant thereafter. Thus, significant gender differences in ferritin exist from the age of 14 years. High levels of SF were associated with obesity, and lower SF levels were associated with anemia and menarche status. We established reference values of SF and TSAT according to age and gender. The reference values for SF calculated in this study can be used to test the association between SF values and other defined diseases in Korean children and adolescents.
Handwriting assessment of Franco-Quebec primary school-age students
Couture, Mélanie; Morin, Marie-France; Coallier, Mélissa; Lavigne, Audrey; Archambault, Patricia; Bolduc, Émilie; Chartier, Émilie; Liard, Karolane; Jasmin, Emmanuelle
2016-12-01
Reasons for referring school-age children to occupational therapy mainly relate to handwriting problems. However, there are no validated tools or reference values for assessing handwriting in francophone children in Canada. This study aimed to adapt and validate the writing tasks described in an English Canadian handwriting assessment protocol and to develop reference values for handwriting speed for francophone children. Three writing tasks from the Handwriting Assessment Protocol-2nd Edition (near-point and far-point copying and dictation) were adapted for Québec French children and administered to 141 Grade 1 ( n = 73) and Grade 2 ( n = 68) students. Reference values for handwriting speed were obtained for near point and far point copying tasks. This adapted protocol and these reference values for speed will improve occupational therapy handwriting assessments for the target population.
Dissolution assessment of allopurinol immediate release tablets by near infrared spectroscopy.
Smetiško, Jelena; Miljanić, Snežana
2017-10-25
The purpose of this study was to develop a NIR spectroscopic method for assessment of drug dissolution from allopurinol immediate release tablets. Thirty three different batches of allopurinol immediate release tablets containing constant amount of the active ingredient, but varying in excipients content and physical properties were introduced in a PLS calibration model. Correlating allopurinol dissolution reference values measured by the routinely used UV/Vis method, with the data extracted from the NIR spectra, values of correlation coefficient, bias, slope, residual prediction determination and root mean square error of prediction (0.9632, 0.328%, 1.001, 3.58, 3.75%) were evaluated. The obtained values implied that the NIR diffuse reflectance spectroscopy could serve as a faster and simpler alternative to the conventional dissolution procedure, even for the tablets with a very fast dissolution rate (>85% in 15minutes). Apart from the possibility of prediction of the allopurinol dissolution rate, the other multivariate technique, PCA, provided additional data on the non-chemical characteristics of the product, which could not be obtained from the reference dissolution values. Analysis on an independent set of samples confirmed that a difference between the UV/Vis reference method and the proposed NIR method was not significant. According to the presented results, the proposed NIR method may be suitable for practical application in routine analysis and for continuously monitoring the product's chemical and physical properties responsible for expected quality. Copyright © 2017 Elsevier B.V. All rights reserved.
Iacone, Roberto; Scanzano, Clelia; Santarpia, Lidia; D'Isanto, Anna; Contaldo, Franco; Pasanisi, Fabrizio
2016-03-31
The micronutrient content in standard enteral mixtures should be closer to the dietary reference values for a healthy population since standard enteral diets are formulated for subjects with no special nutritional needs. This study compares the micronutrient content of the most common enteral nutrition (EN) formulas with European dietary reference values (DRVs) for healthy population. Sixty-two nutritionally complete enteral formulas were considered. The micronutrient content was calculated by multiplying the value reported on the nutritional information panel of each formula by the daily dose usually prescribed. The comparison between the micronutrient content of all enteral formulas evaluated and the DRVs indicates that daily fluoride and vitamin K requirements were not covered, while an oversupply of many other micronutrients was provided. Moreover, in some enteral formulas, at a dose of 2000 Kcal/day, zinc and vitamin A content exceeded the tolerable upper limits and, for one diabetes-specific enteral formula, the chromium content exceeded the relevant European standards in both 1500 and 2000 Kcal/day diets. Most enteral formulas evaluated are generally suitable for patients on long-term total EN and formulas with higher content of a specific micronutrient may be a useful tool for patients affected by specific clinical conditions, at least for a period of time, then switching to standard enteral mixtures. The availability of nutritional enteral formulas, well balanced also for micronutrient intake, will further improve individualized treatments, particularly for patients on long-term total EN.
Informative graphing of continuous safety variables relative to normal reference limits.
Breder, Christopher D
2018-05-16
Interpreting graphs of continuous safety variables can be complicated because differences in age, gender, and testing site methodologies data may give rise to multiple reference limits. Furthermore, data below the lower limit of normal are compressed relative to those points above the upper limit of normal. The objective of this study is to develop a graphing technique that addresses these issues and is visually intuitive. A mock dataset with multiple reference ranges is initially used to develop the graphing technique. Formulas are developed for conditions where data are above the upper limit of normal, normal, below the lower limit of normal, and below the lower limit of normal when the data value equals zero. After the formulae are developed, an anonymized dataset from an actual set of trials for an approved drug is evaluated comparing the technique developed in this study to standard graphical methods. Formulas are derived for the novel graphing method based on multiples of the normal limits. The formula for values scaled between the upper and lower limits of normal is a novel application of a readily available scaling formula. The formula for the lower limit of normal is novel and addresses the issue of this value potentially being indeterminate when the result to be scaled as a multiple is zero. The formulae and graphing method described in this study provides a visually intuitive method to graph continuous safety data including laboratory values, vital sign data.
[Effect of emotional content and self reference of learning materials on recall performance].
Spies, K
1994-01-01
It is assumed that high affective value and high self-reference of learning material help to improve memory performance as these factors allow better memory consolidation (activation hypothesis) or better integration of the new material into existing knowledge structures (extent-of-processing hypothesis). To test this assumption, 60 subjects were shown 16 short advertising films characterized by low vs. high affective value and low vs. high self-reference. Both factors were varied within subjects. After the films had each been presented twice, subjects had to recall the product names and answer two questions to each film. Results showed for both dependent variables that films with high affective values were better remembered than films with low affective values. The same held true--though to a lower extent--with respect to self-reference. According to the expected linear trend, performance was best for material scoring high on affective value as well as on self-reference, while it was worst for material scoring low on both factors.
[Reference values for lead in blood in urban population in southern Brazil].
Paoliello, M M; Gutierrez, P R; Turini, C A; Matsuo, T; Mezzaroba, L; Barbosa, D S; Carvalho, S R; Alvarenga, A L; Rezende, M I; Figueiroa, G A; Leite, V G; Gutierrez, A C; Lobo, B C; Cascales, R A
2001-05-01
To describe the reference values for lead in blood in an urban population in the city of Londrina, in the state of Paraná, Brazil. The reference population was composed of 520 adult volunteers who were assessed from November 1994 to December 1996. Exclusion criteria were: occupational exposure to lead, exposure through personal habits or practices, smoking more than 10 cigarettes per day, and living near industrial plants or other places that use lead in their production processes. Also excluded were individuals with abnormal clinical or laboratory results or with chronic diseases or cardiovascular disorders. Lead blood levels were determined using air-acetylene flame atomic absorption spectrophotometry. The detectable limit was 1.23 micrograms/dL. After the analyses of lead in blood, the following values were determined: minimum value, first quartile, median, third quartile, and maximum value; geometric mean; 95% confidence interval; experimental interval; and reference value. The reference values for lead in blood ranged from 1.20 micrograms/dL to 13.72 micrograms/dL. The geometric mean was 5.5 micrograms/dL. In general, the values found in this study are lower than those that have been reported for other countries. Additional data should be gathered from Brazilian populations living in more-industrialized areas.
Yiming, Gulinuer; Zhou, Xianhui; Lv, Wenkui; Peng, Yi; Zhang, Wenhui; Cheng, Xinchun; Li, Yaodong; Xing, Qiang; Zhang, Jianghua; Zhou, Qina; Zhang, Ling; Lu, Yanmei; Wang, Hongli; Tang, Baopeng
2017-01-01
Brachial-ankle pulse wave velocity (baPWV), a direct measure of aortic stiffness, has increasingly become an important assessment for cardiovascular risk. The present study established the reference and normal values of baPWV in a Central Asia population in Xinjiang, China. We recruited participants from a central Asia population in Xinjiang, China. We performed multiple regression analysis to investigate the determinants of baPWV. The median and 10th-90th percentiles were calculated to establish the reference and normal values based on these categories. In total, 5,757 Han participants aged 15-88 years were included in the present study. Spearman correlation analysis showed that age (r = 0.587, p < 0.001) and mean blood pressure (MBP, r = 0.599, p <0.001) were the major factors influencing the values of baPWV in the reference population. Furthermore, in the multiple linear regression analysis, the standardized regression coefficients of age (0.445) and MBP (0.460) were much higher than those of body mass index, triglyceride, and glycemia (-0.054, 0.035, and 0.033, respectively). In the covariance analysis, after adjustment for age and MBP, only diabetes was the significant independent determinant of baPWV (p = 0.009). Thus, participants with diabetes were excluded from the reference value population. The reference values ranged from 14.3 to 25.2 m/s, and the normal values ranged from 13.9 to 21.2 m/s. This is the first study that has established the reference and normal values for baPWV according to age and blood pressure in a Central Asia population.
Torén, Kjell; Murgia, Nicola; Schiöler, Linus; Bake, Björn; Olin, Anna-Carin
2017-08-25
Fractional exhaled nitric oxide (FE NO ) is used to assess of airway inflammation; diagnose asthma and monitor adherence to advised therapy. Reliable and accurate reference values for FE NO are needed for both non-smoking and current smoking adults in the clinical setting. The present study was performed to establish reference adult FE NO values among never-smokers, former smokers and current smokers. FE NO was measured in 5265 subjects aged 25-75 years in a general-population study, using a chemiluminescence (Niox ™) analyser according to the guidelines of the American Thoracic Society and the European Respiratory Society. Atopy was based on the presence of immunoglobulin E (IgE) antibodies to common inhalant allergens (measured using Phadiatop® test). Spirometry without bronchodilation was performed and forced vital capacity (FVC), forced expired volume in 1 s (FEV 1 ) and the ratio of FEV 1 to FVC values were obtained. After excluding subjects with asthma, chronic bronchitis, spirometric airway obstruction and current cold, 3378 subjects remained. Equations for predictions of FE NO values were modelled using nonparametric regression models. FE NO levels were similar in never-smokers and former smokers, and these two groups were therefore merged into a group termed "non-smokers". Reference equations, including the 5th and 95th percentiles, were generated for female and male non-smokers, based on age, height and atopy. Regression models for current smokers were unstable. Hence, the proposed reference values for current smokers are based on the univariate distribution of FE NO and fixed cut-off limits. Reference values for FE NO among respiratory healthy non-smokers should be outlined stratified for gender using individual reference values. For current smokers separate cut-off limits are proposed.
Vineyard water status assessment using on-the-go thermal imaging and machine learning.
Gutiérrez, Salvador; Diago, María P; Fernández-Novales, Juan; Tardaguila, Javier
2018-01-01
The high impact of irrigation in crop quality and yield in grapevine makes the development of plant water status monitoring systems an essential issue in the context of sustainable viticulture. This study presents an on-the-go approach for the estimation of vineyard water status using thermal imaging and machine learning. The experiments were conducted during seven different weeks from July to September in season 2016. A thermal camera was embedded on an all-terrain vehicle moving at 5 km/h to take on-the-go thermal images of the vineyard canopy at 1.2 m of distance and 1.0 m from the ground. The two sides of the canopy were measured for the development of side-specific and global models. Stem water potential was acquired and used as reference method. Additionally, reference temperatures Tdry and Twet were determined for the calculation of two thermal indices: the crop water stress index (CWSI) and the Jones index (Ig). Prediction models were built with and without considering the reference temperatures as input of the training algorithms. When using the reference temperatures, the best models casted determination coefficients R2 of 0.61 and 0.58 for cross validation and prediction (RMSE values of 0.190 MPa and 0.204 MPa), respectively. Nevertheless, when the reference temperatures were not considered in the training of the models, their performance statistics responded in the same way, returning R2 values up to 0.62 and 0.65 for cross validation and prediction (RMSE values of 0.190 MPa and 0.184 MPa), respectively. The outcomes provided by the machine learning algorithms support the use of thermal imaging for fast, reliable estimation of a vineyard water status, even suppressing the necessity of supervised acquisition of reference temperatures. The new developed on-the-go method can be very useful in the grape and wine industry for assessing and mapping vineyard water status.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Konstantinidis, Anastasios C.; Olivo, Alessandro; Speller, Robert D.
2011-12-15
Purpose: The x-ray performance evaluation of digital x-ray detectors is based on the calculation of the modulation transfer function (MTF), the noise power spectrum (NPS), and the resultant detective quantum efficiency (DQE). The flat images used for the extraction of the NPS should not contain any fixed pattern noise (FPN) to avoid contamination from nonstochastic processes. The ''gold standard'' method used for the reduction of the FPN (i.e., the different gain between pixels) in linear x-ray detectors is based on normalization with an average reference flat-field. However, the noise in the corrected image depends on the number of flat framesmore » used for the average flat image. The aim of this study is to modify the standard gain correction algorithm to make it independent on the used reference flat frames. Methods: Many publications suggest the use of 10-16 reference flat frames, while other studies use higher numbers (e.g., 48 frames) to reduce the propagated noise from the average flat image. This study quantifies experimentally the effect of the number of used reference flat frames on the NPS and DQE values and appropriately modifies the gain correction algorithm to compensate for this effect. Results: It is shown that using the suggested gain correction algorithm a minimum number of reference flat frames (i.e., down to one frame) can be used to eliminate the FPN from the raw flat image. This saves computer memory and time during the x-ray performance evaluation. Conclusions: The authors show that the method presented in the study (a) leads to the maximum DQE value that one would have by using the conventional method and very large number of frames and (b) has been compared to an independent gain correction method based on the subtraction of flat-field images, leading to identical DQE values. They believe this provides robust validation of the proposed method.« less
Vineyard water status assessment using on-the-go thermal imaging and machine learning
Gutiérrez, Salvador; Diago, María P.; Fernández-Novales, Juan
2018-01-01
The high impact of irrigation in crop quality and yield in grapevine makes the development of plant water status monitoring systems an essential issue in the context of sustainable viticulture. This study presents an on-the-go approach for the estimation of vineyard water status using thermal imaging and machine learning. The experiments were conducted during seven different weeks from July to September in season 2016. A thermal camera was embedded on an all-terrain vehicle moving at 5 km/h to take on-the-go thermal images of the vineyard canopy at 1.2 m of distance and 1.0 m from the ground. The two sides of the canopy were measured for the development of side-specific and global models. Stem water potential was acquired and used as reference method. Additionally, reference temperatures Tdry and Twet were determined for the calculation of two thermal indices: the crop water stress index (CWSI) and the Jones index (Ig). Prediction models were built with and without considering the reference temperatures as input of the training algorithms. When using the reference temperatures, the best models casted determination coefficients R2 of 0.61 and 0.58 for cross validation and prediction (RMSE values of 0.190 MPa and 0.204 MPa), respectively. Nevertheless, when the reference temperatures were not considered in the training of the models, their performance statistics responded in the same way, returning R2 values up to 0.62 and 0.65 for cross validation and prediction (RMSE values of 0.190 MPa and 0.184 MPa), respectively. The outcomes provided by the machine learning algorithms support the use of thermal imaging for fast, reliable estimation of a vineyard water status, even suppressing the necessity of supervised acquisition of reference temperatures. The new developed on-the-go method can be very useful in the grape and wine industry for assessing and mapping vineyard water status. PMID:29389982
Wilson, John-James; Sing, Kong-Wah; Sofian-Azirun, Mohd
2013-01-01
The objective of this study was to build a DNA barcode reference library for the true butterflies of Peninsula Malaysia and assess the value of attaching subspecies names to DNA barcode records. A new DNA barcode library was constructed with butterflies from the Museum of Zoology, University of Malaya collection. The library was analysed in conjunction with publicly available DNA barcodes from other Asia-Pacific localities to test the ability of the DNA barcodes to discriminate species and subspecies. Analyses confirmed the capacity of the new DNA barcode reference library to distinguish the vast majority of species (92%) and revealed that most subspecies possessed unique DNA barcodes (84%). In some cases conspecific subspecies exhibited genetic distances between their DNA barcodes that are typically seen between species, and these were often taxa that have previously been regarded as full species. Subspecies designations as shorthand for geographically and morphologically differentiated groups provide a useful heuristic for assessing how such groups correlate with clustering patterns of DNA barcodes, especially as the number of DNA barcodes per species in reference libraries increases. Our study demonstrates the value in attaching subspecies names to DNA barcode records as they can reveal a history of taxonomic concepts and expose important units of biodiversity.
Serum transferrin receptor status of healthy adult Arabs.
Knox-Macaulay, Huxley; Gravell, David; Elender, Frances
2007-01-01
Several studies have provided reference ranges for the concentration of serum transferrin receptor (sTfR) in various white populations, but there is a dearth of relevant reference sTfR data in non-whites. The aim of this investigation was to establish sTfR reference ranges and mean values for a healthy non-white Arab population that could be used also for Arabs worldwide. sTfR and serum ferritin concentrations were estimated by immunoassays and blood counts were determined by conventional methods. Analysis of the data of 114 volunteer Arab blood donors (91 male, 23 female) revealed a higher mean sTfR concentration in males of 22.6+/-8.1 nmol/L (range 10.9-38.7 nmol/L) compared to that in females of 18.7+/-4.4 nmol/L (range 10.7-25.8 nmol/L, p=0.001). There was no significant correlation of sTfR concentration with age, serum ferritin level, or blood haemoglobin level, but a strong inverse correlation was demonstrated with mean cell volume and mean cell haemoglobin of red cells. Iron-replete volunteer subjects with alpha-thalassaemia trait appear to have relatively high mean sTfR concentration. We recommend the use of gender-dependent sTfR reference values for Arabs.
Wilson, John-James; Sing, Kong-Wah; Sofian-Azirun, Mohd
2013-01-01
The objective of this study was to build a DNA barcode reference library for the true butterflies of Peninsula Malaysia and assess the value of attaching subspecies names to DNA barcode records. A new DNA barcode library was constructed with butterflies from the Museum of Zoology, University of Malaya collection. The library was analysed in conjunction with publicly available DNA barcodes from other Asia-Pacific localities to test the ability of the DNA barcodes to discriminate species and subspecies. Analyses confirmed the capacity of the new DNA barcode reference library to distinguish the vast majority of species (92%) and revealed that most subspecies possessed unique DNA barcodes (84%). In some cases conspecific subspecies exhibited genetic distances between their DNA barcodes that are typically seen between species, and these were often taxa that have previously been regarded as full species. Subspecies designations as shorthand for geographically and morphologically differentiated groups provide a useful heuristic for assessing how such groups correlate with clustering patterns of DNA barcodes, especially as the number of DNA barcodes per species in reference libraries increases. Our study demonstrates the value in attaching subspecies names to DNA barcode records as they can reveal a history of taxonomic concepts and expose important units of biodiversity. PMID:24282514
Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China.
Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li'an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling
2016-03-01
A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box-Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China.
Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China
Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li’an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling
2016-01-01
Abstract A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box–Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China. PMID:26945390
Work ability of workers in western China: reference data.
Lin, Sihao; Wang, Zhiming; Wang, Mianzhen
2006-03-01
The Work Ability Index (WAI) is a validated and widely used research tool. Reference data for Chinese workers by age, gender and work content are poorly documented or lacking. To provide reference data for work ability among workers in western China. A random sample of 10 218 workers (including manual, professional, clerical and semi-skilled workers) in western China, aged 16-69 years, was taken from several studies and the WAI questionnaire was administered. All the WAI scores were distributed continuously and nearly normally. The WAI for female workers was significantly higher than for males (P < 0.01) and the 'poor' WAI category only accounted for 3% of females, against 6% of males. WAI scores declined with age and changed variably among workers according to work content and age. Mean WAI scores of manual workers declined rapidly beyond the age of 35 years, and beyond age 45 years for professional and clerical workers. WAI scores were distributed differently according to work content and age group (P < 0.01). WAI categories differed by work content and age group both for male and female workers. WAI is validated in Chinese occupational practices. Some reference data are different from Finnish data. This study provides gender, age and work-content-specific WAI reference values that will help enable comparison and intervention evaluation in further studies.
Marketing a Radiology Practice.
Levin, David C; Rao, Vijay M; Flanders, Adam E; Sundaram, Baskaran; Colarossi, Margaret
2016-10-01
In addition to being a profession, the practice of radiology is a business, and marketing is an important part of that business. There are many facets to marketing a radiology practice. The authors present a number of ideas on how to go about doing this. Some marketing methods can be directed to both patients and referring physicians. Others should be directed just to patients, while still others should be directed just to referring physicians. Aside from marketing, many of them provide value to both target audiences. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Mazonakis, Michalis; Sahin, Bunyamin; Pagonidis, Konstantin; Damilakis, John
2011-06-01
The aim of this study was to combine the stereological technique with magnetic resonance (MR) imaging data for the volumetric and functional analysis of the left ventricle (LV). Cardiac MR examinations were performed in 13 consecutive subjects with known or suspected coronary artery disease. The end-diastolic volume (EDV), end-systolic volume, ejection fraction (EF), and mass were estimated by stereology using the entire slice set depicting LV and systematic sampling intensities of 1/2 and 1/3 that provided samples with every second and third slice, respectively. The repeatability of stereology was evaluated. Stereological assessments were compared with the reference values derived by manually tracing the endocardial and epicardial contours on MR images. Stereological EDV and EF estimations obtained by the 1/3 systematic sampling scheme were significantly different from those by manual delineation (P < .05). No difference was observed between the reference values and the LV parameters estimated by the entire slice set or a sampling intensity of 1/2 (P > .05). For these stereological approaches, a high correlation (r(2) = 0.80-0.93) and clinically acceptable limits of agreement were found with the reference method. Stereological estimations obtained by both sample sizes presented comparable coefficient of variation values of 2.9-5.8%. The mean time for stereological measurements on the entire slice set was 3.4 ± 0.6 minutes and it was reduced to 2.5 ± 0.5 minutes with the 1/2 systematic sampling scheme. Stereological analysis on systematic samples of MR slices generated by the 1/2 sampling intensity provided efficient and quick assessment of LV volumes, function, and mass. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.
Physical fitness and anthropometric normative values among Colombian-Indian schoolchildren.
Ramos-Sepúlveda, Jeison Alexander; Ramírez-Vélez, Robinson; Correa-Bautista, Jorge Enrique; Izquierdo, Mikel; García-Hermoso, Antonio
2016-09-13
Substantial evidence indicates that children's physical fitness levels are markers of their lifestyles and their cardio-metabolic health profile and are predictors of the future risk of chronic diseases such as obesity, cardiometabolic disease, skeletal health and mental health. However, fitness reference values for ethnic children and adolescents have not been published in a Latin-American population. Therefore, the aim of the study was to provide sex- and age-specific physical fitness and anthropometric reference standards among Colombian-Indian schoolchildren. A sample of 576 participants (319 boys and 257 girls) aged 10 to 17 years old was assessed using the FUPRECOL test battery. Four components of physical fitness were measured: 1) morphological component: height, weight, body mass index (BMI), waist circumference (WC), triceps skinfold, subscapular skinfold, and body fat (%); 2) musculoskeletal component: handgrip and standing long jump test; 3) motor component: speed/agility test (4 × 10 m shuttle run); and 4) cardiorespiratory component: course-navette 20 m, shuttle run test and estimation of maximal oxygen consumption by VO2max indirect. Centile smoothed curves for the 3(rd), 10(th), 25(th), 50(th), 75(th), 90(th) and 97(th) percentiles were calculated using Cole's LMS method. Our results show that weight, height and BMI in each age group were higher in boys than in girls. In each groups, age showed a significant effect for BMI and WC. Boys showed better than girls in cardiorespiratory fitness, lower- and upper-limb strength and speed/agility and girls performed better in low back flexibility. Our results provide for the first time sex- and age-specific physical fitness and anthropometric reference values for Colombian Nasa Indian children and adolescents aged 10-17.9 years.
Accuracy of a continuous noninvasive hemoglobin monitor in intensive care unit patients.
Frasca, Denis; Dahyot-Fizelier, Claire; Catherine, Karen; Levrat, Quentin; Debaene, Bertrand; Mimoz, Olivier
2011-10-01
To determine whether noninvasive hemoglobin measurement by Pulse CO-Oximetry could provide clinically acceptable absolute and trend accuracy in critically ill patients, compared to other invasive methods of hemoglobin assessment available at bedside and the gold standard, the laboratory analyzer. Prospective study. Surgical intensive care unit of a university teaching hospital. Sixty-two patients continuously monitored with Pulse CO-Oximetry (Masimo Radical-7). None. Four hundred seventy-one blood samples were analyzed by a point-of-care device (HemoCue 301), a satellite lab CO-Oximeter (Siemens RapidPoint 405), and a laboratory hematology analyzer (Sysmex XT-2000i), which was considered the reference device. Hemoglobin values reported from the invasive methods were compared to the values reported by the Pulse CO-Oximeter at the time of blood draw. When the case-to-case variation was assessed, the bias and limits of agreement were 0.0±1.0 g/dL for the Pulse CO-Oximeter, 0.3±1.3g/dL for the point-of-care device, and 0.9±0.6 g/dL for the satellite lab CO-Oximeter compared to the reference method. Pulse CO-Oximetry showed similar trend accuracy as satellite lab CO-Oximetry, whereas the point-of-care device did not appear to follow the trend of the laboratory analyzer as well as the other test devices. When compared to laboratory reference values, hemoglobin measurement with Pulse CO-Oximetry has absolute accuracy and trending accuracy similar to widely used, invasive methods of hemoglobin measurement at bedside. Hemoglobin measurement with pulse CO-Oximetry has the additional advantages of providing continuous measurements, noninvasively, which may facilitate hemoglobin monitoring in the intensive care unit.
[Investigation of adolescents' bone metabolism in the western part of Transdanubia].
Csákváry, Violetta; Puskás, Tamás; Bödecs, Tamás; Lôcsei, Zoltán; Oroszlán, György; Kovács, L Gábor; Toldy, Erzsébet
2009-10-25
Childhood reference range based on the age is not available in Hungary, therefore the diagnosis and therapy of bone metabolic diseases of childhood are subject to difficulties. The aim of this work is to provide information about the adolescents' results of bone mineral density and bone biomarkers. Measurements were performed in 169 healthy adolescents (98 girls, 71 boys, age: 17.0+/-1.2 years). Bone mineral content (BMC) and bone mineral density (BMD) of the lumbar spine were measured using Double X-ray Absorptiometry (DXA, LUNAR, GE Health Care, USA) and Z-score values were analyzed using different reference population. In the serum, bone biomarkers osteocalcin (OC) and beta-crosslaps (beta-Cl) were measured by a fully automated, electrochemiluminescence immunoassay method (Elecsys-2010, Roche). Data were analyzed according to gender and the Tanner stage and grade system. Associations between body mass index (BMI), calcium intake, consumption of soft drinks and coke, and physical exercise were investigated. BMC values for both age groups were significantly elevated in boys of the Tanner stage V. (15-16 years: 62.9+/-14.3 g; 17-19 years: 69.8+/-9.3g) than in girls (58.1+/-10.4; 61.6+/-8.5 g) (p<0.001). BMD values were higher in girls, than in boys (1.17+/-0.12 g/cm 2 vs. 1.13+/-0.11 g/cm 2) (p<0.05). OC and beta-Cl levels showed negative correlation with age in both gender (p<0.01), while OC and beta-Cl levels were higher in boys, than in girls (p<0.001). Elevation of BMC and BMD values were associated with increase of BMI in both gender (p<0.05), but the biomarkers in thin girls were higher, than in overweight girls (p<0.05). Authors obtained excellent correlations between the BMD-Z-score values compared to the German standard and to their own population (girls: r=0.97, boys: 0.88), but the absolute values significantly differed from one another. 80% of adolescents are on a diet with insufficient calcium intake, while 38% of them do not play sport regularly. Excessive intake of soft drinks was determined in 60% of adolescents. In the case of insufficient calcium intake (4.7%, 6/127), low bone mass was measured using the Z-score of the German reference values. Among children with adequate calcium intake, BMD assessed by DXA was normal. These data help to determine normal reference values among healthy high school students. Further studies are needed in wider range of young population for the establishment of Hungarian reference values of bone markers.
Woodworth, M.T.; Connor, B.F.
2001-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-165 (trace constituents), M-158 (major constituents), N-69 (nutrient constituents), N-70 (nutrient constituents), P-36 (low ionic-strength constituents), and Hg-32 (mercury) -- that were distributed in April 2001 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 73 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Survey of the Physical and Environmental Parameters of the Moon
NASA Technical Reports Server (NTRS)
Niedz, F. J.; Kopal, Zdenek
1963-01-01
This document presents, in summary, a compilation of the physical and environmental parameters of the moon. A determined attempt has been made to be objective at all times. Many of the physical sciences are presented in sufficient depth to adequately identify the basic information available. It is expected that the appropriate references will be consulted when additional detail is required. It is obvious both from the text and the reference material that divergent opinions prevail and uncertainties exist in almost every phase of lunar science; e.g., the existence of the lunar bulge, the thickness of the dust layer, etc. No pretense is made to resolve these differences, but by bringing together many references, it is hoped that some contribution will be made in lunar science. The subject index will be of particular value since it relates the reference section by subject. A glossary of terms used throughout the text is also provided.
Woodworth, M.T.; Conner, B.F.
2002-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T- 169 (trace constituents), M- 162 (major constituents), N-73 (nutrient constituents), N-74 (nutrient constituents), P-38 (low ionic-strength constituents), and Hg-34 (mercury) -- that were distributed in March 2002 to laboratories enrolled in the U.S. Geological Survey sponsored intedaboratory testing program. Analytical data received from 93 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Woodworth, Mark T.; Connor, Brooke F.
2003-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-171 (trace constituents), M-164 (major constituents), N-75 (nutrient constituents), N-76 (nutrient constituents), P-39 (low ionic-strength constituents), and Hg-35 (mercury) -- that were distributed in September 2002 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 102 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Woodworth, Mark T.; Connor, Brooke F.
2002-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-167 (trace constituents), M-160 (major constituents), N-71 (nutrient constituents), N-72 (nutrient constituents), P-37 (low ionic-strength constituents), and Hg-33 (mercury) -- that were distributed in September 2001 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 98 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Farrar, Jerry W.; Copen, Ashley M.
2000-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-161 (trace constituents), M-154 (major constituents), N-65 (nutrient constituents), N-66 nutrient constituents), P-34 (low ionic strength constituents), and Hg-30 (mercury) -- that were distributed in March 2000 to 144 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 132 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Farrar, T.W.
2000-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-159 (trace constituents), M-152 (major constituents), N-63 (nutrient constituents), N-64 (nutrient constituents), P-33 (low ionic strength constituents), and Hg-29 (mercury) -- that were distributed in October 1999 to 149 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 131 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Woodworth, Mark T.; Connor, Brooke F.
2003-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-173 (trace constituents), M-166 (major constituents), N-77 (nutrient constituents), N-78 (nutrient constituents), P-40 (low ionic-strength constituents), and Hg-36 (mercury) -- that were distributed in March 2003 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 110 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Connor, B.F.; Currier, J.P.; Woodworth, M.T.
2001-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-163 (trace constituents), M-156 (major constituents), N-67 (nutrient constituents), N-68 (nutrient constituents), P-35 (low ionic strength constituents), and Hg-31 (mercury) -- that were distributed in October 2000 to 126 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 122 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
NASA Technical Reports Server (NTRS)
Susskind, J.; Reuter, D.
1986-01-01
IR and microwave remote sensing data collected with the HIRS2 and MSU sensors on the NOAA polar-orbiting satellites were evaluated for their effectiveness as bases for determining the cloud cover and cloud physical characteristics. Techniques employed to adjust for day-night alterations in the radiance fields are described, along with computational procedures applied to compare scene pixel values with reference values for clear skies. Sample results are provided for the mean cloud coverage detected over South America and Africa June 1979, with attention given to concurrent surface pressure and cloud top pressure values.
Shaikh, Faiq; Hendrata, Kenneth; Kolowitz, Brian; Awan, Omer; Shrestha, Rasu; Deible, Christopher
2017-06-01
In the era of value-based healthcare, many aspects of medical care are being measured and assessed to improve quality and reduce costs. Radiology adds enormously to health care costs and is under pressure to adopt a more efficient system that incorporates essential metrics to assess its value and impact on outcomes. Most current systems tie radiologists' incentives and evaluations to RVU-based productivity metrics and peer-review-based quality metrics. In a new potential model, a radiologist's performance will have to increasingly depend on a number of parameters that define "value," beginning with peer review metrics that include referrer satisfaction and feedback from radiologists to the referring physician that evaluates the potency and validity of clinical information provided for a given study. These new dimensions of value measurement will directly impact the cascade of further medical management. We share our continued experience with this project that had two components: RESP (Referrer Evaluation System Pilot) and FRACI (Feedback from Radiologist Addressing Confounding Issues), which were introduced to the clinical radiology workflow in order to capture referrer-based and radiologist-based feedback on radiology reporting. We also share our insight into the principles of design thinking as applied in its planning and execution.
Ford, Karl L; Beyer, W Nelson
2014-03-01
Thousands of hard rock mines exist in the western USA and in other parts of the world as a result of historic and current gold, silver, lead, and mercury mining. Many of these sites in the USA are on public lands. Typical mine waste associated with these sites are tailings and waste rock dumps that may be used by wildlife and open-range livestock. This report provides wildlife screening criteria levels for metals in soil and mine waste to evaluate risk and to determine the need for site-specific risk assessment, remediation, or a change in management practices. The screening levels are calculated from toxicity reference values based on maximum tolerable levels of metals in feed, on soil and plant ingestion rates, and on soil to plant uptake factors for a variety of receptors. The metals chosen for this report are common toxic metals found at mining sites: arsenic, cadmium, copper, lead, mercury, and zinc. The resulting soil screening values are well above those developed by the US Environmental Protection Agency. The difference in values was mainly a result of using toxicity reference values that were more specific to the receptors addressed rather than the most sensitive receptor.
Ford, Karl L; Beyer, W. Nelson
2014-01-01
Thousands of hard rock mines exist in the western USA and in other parts of the world as a result of historic and current gold, silver, lead, and mercury mining. Many of these sites in the USA are on public lands. Typical mine waste associated with these sites are tailings and waste rock dumps that may be used by wildlife and open-range livestock. This report provides wildlife screening criteria levels for metals in soil and mine waste to evaluate risk and to determine the need for site-specific risk assessment, remediation, or a change in management practices. The screening levels are calculated from toxicity reference values based on maximum tolerable levels of metals in feed, on soil and plant ingestion rates, and on soil to plant uptake factors for a variety of receptors. The metals chosen for this report are common toxic metals found at mining sites: arsenic, cadmium, copper, lead, mercury, and zinc. The resulting soil screening values are well above those developed by the US Environmental Protection Agency. The difference in values was mainly a result of using toxicity reference values that were more specific to the receptors addressed rather than the most sensitive receptor.
Beiras, Ricardo; Durán, Iria
2014-12-01
Some relevant shortcomings have been identified in the current approach for the classification of ecological status in marine water bodies, leading to delays in the fulfillment of the Water Framework Directive objectives. Natural variability makes difficult to settle fixed reference values and boundary values for the Ecological Quality Ratios (EQR) for the biological quality elements. Biological responses to environmental degradation are frequently of nonmonotonic nature, hampering the EQR approach. Community structure traits respond only once ecological damage has already been done and do not provide early warning signals. An alternative methodology for the classification of ecological status integrating chemical measurements, ecotoxicological bioassays and community structure traits (species richness and diversity), and using multivariate analyses (multidimensional scaling and cluster analysis), is proposed. This approach does not depend on the arbitrary definition of fixed reference values and EQR boundary values, and it is suitable to integrate nonlinear, sensitive signals of ecological degradation. As a disadvantage, this approach demands the inclusion of sampling sites representing the full range of ecological status in each monitoring campaign. National or international agencies in charge of coastal pollution monitoring have comprehensive data sets available to overcome this limitation.
Model Reduction via Principe Component Analysis and Markov Chain Monte Carlo (MCMC) Methods
NASA Astrophysics Data System (ADS)
Gong, R.; Chen, J.; Hoversten, M. G.; Luo, J.
2011-12-01
Geophysical and hydrogeological inverse problems often include a large number of unknown parameters, ranging from hundreds to millions, depending on parameterization and problems undertaking. This makes inverse estimation and uncertainty quantification very challenging, especially for those problems in two- or three-dimensional spatial domains. Model reduction technique has the potential of mitigating the curse of dimensionality by reducing total numbers of unknowns while describing the complex subsurface systems adequately. In this study, we explore the use of principal component analysis (PCA) and Markov chain Monte Carlo (MCMC) sampling methods for model reduction through the use of synthetic datasets. We compare the performances of three different but closely related model reduction approaches: (1) PCA methods with geometric sampling (referred to as 'Method 1'), (2) PCA methods with MCMC sampling (referred to as 'Method 2'), and (3) PCA methods with MCMC sampling and inclusion of random effects (referred to as 'Method 3'). We consider a simple convolution model with five unknown parameters as our goal is to understand and visualize the advantages and disadvantages of each method by comparing their inversion results with the corresponding analytical solutions. We generated synthetic data with noise added and invert them under two different situations: (1) the noised data and the covariance matrix for PCA analysis are consistent (referred to as the unbiased case), and (2) the noise data and the covariance matrix are inconsistent (referred to as biased case). In the unbiased case, comparison between the analytical solutions and the inversion results show that all three methods provide good estimates of the true values and Method 1 is computationally more efficient. In terms of uncertainty quantification, Method 1 performs poorly because of relatively small number of samples obtained, Method 2 performs best, and Method 3 overestimates uncertainty due to inclusion of random effects. However, in the biased case, only Method 3 correctly estimates all the unknown parameters, and both Methods 1 and 2 provide wrong values for the biased parameters. The synthetic case study demonstrates that if the covariance matrix for PCA analysis is inconsistent with true models, the PCA methods with geometric or MCMC sampling will provide incorrect estimates.
On-line calibration of high-response pressure transducers during jet-engine testing
NASA Technical Reports Server (NTRS)
Armentrout, E. C.
1974-01-01
Jet engine testing is reported concerned with the effect of inlet pressure and temperature distortions on engine performance and involves the use of numerous miniature pressure transducers. Despite recent improvements in the manufacture of miniature pressure transducers, they still exhibit sensitivity change and zero-shift with temperature and time. To obtain meaningful data, a calibration system is needed to determine these changes. A system has been developed which provides for computer selection of appropriate reference pressures selected from nine different sources to provide a two- or three-point calibration. Calibrations are made on command, before and sometimes after each data point. A unique no leak matrix valve design is used in the reference pressure system. Zero-shift corrections are measured and the values are automatically inserted into the data reduction program.
Low speed phaselock speed control system. [for brushless dc motor
NASA Technical Reports Server (NTRS)
Fulcher, R. W.; Sudey, J. (Inventor)
1975-01-01
A motor speed control system for an electronically commutated brushless dc motor is provided which includes a phaselock loop with bidirectional torque control for locking the frequency output of a high density encoder, responsive to actual speed conditions, to a reference frequency signal, corresponding to the desired speed. The system includes a phase comparator, which produces an output in accordance with the difference in phase between the reference and encoder frequency signals, and an integrator-digital-to-analog converter unit, which converts the comparator output into an analog error signal voltage. Compensation circuitry, including a biasing means, is provided to convert the analog error signal voltage to a bidirectional error signal voltage which is utilized by an absolute value amplifier, rotational decoder, power amplifier-commutators, and an arrangement of commutation circuitry.
Summary Diagrams for Coupled Hydrodynamic-Ecosystem Model Skill Assessment
2009-01-01
reference point have the smallest unbiased RMSD value (Fig. 3). It would appear that the cluster of model points closest to the reference point may...total RMSD values. This is particularly the case for phyto- plankton absorption (Fig. 3B) where the cluster of points closest to the reference...pattern statistics and the bias (difference of mean values) each magnitude of the total Root-Mean-Square Difference ( RMSD ). An alternative skill score and
Reference value sensitivity of measures of unfair health inequality
García-Gómez, Pilar; Schokkaert, Erik; Van Ourti, Tom
2014-01-01
Most politicians and ethical observers are not interested in pure health inequalities, as they want to distinguish between different causes of health differences. Measures of “unfair” inequality - direct unfairness and the fairness gap, but also the popular standardized concentration index - therefore neutralize the effects of what are considered to be “legitimate” causes of inequality. This neutralization is performed by putting a subset of the explanatory variables at reference values, e.g. their means. We analyze how the inequality ranking of different policies depends on the specific choice of reference values. We show with mortality data from the Netherlands that the problem is empirically relevant and we suggest a statistical method for fixing the reference values. PMID:24954998
ERIC Educational Resources Information Center
Oakes, Jeannie; Quartz, Karen Hunter; Ryan, Steve; Lipton, Martin
Education reform based on technical and rational processes often short-circuits reform because it is uncontentious, abstract, and provides educators with no legitimate ways to question the marketplace values and policies that drive much contemporary school reform. The perspective referred to as "betterment" is an alternative reform that…
Code of Federal Regulations, 2011 CFR
2011-01-01
... providing financing for economic development projects for targeted beneficiaries, and, for community... undertaken a confirmation at the request or with the consent of the issuer, for the giving of value under a... “§ 1266.1” is added; in SHFA associate SHFA associate the reference to “§ 1269.1” is removed and “§ 1264.1...
JEDI Transmission Line Model | Jobs and Economic Development Impact Models
, reasonable default values are provided. Individual projects may vary and when possible, project specific data Line Model rel. TL12.23.16. JEDI Transmission Line Model User Reference Guide Using MS Excel 2007 When ;High." Set the level to "Medium" or "Low" and then re-open the JEDI worksheet
The Development of a Strategy for Vocational Education and Training: Experiences from Montenegro
ERIC Educational Resources Information Center
Hoppe, Melanie; Burmester, Jeanette; Ebben, Jan
2011-01-01
This article addresses the problem that many countries lack a strategic orientation in reforming their vocational education and training (VET) systems, and therefore refers to the added value of a distinct VET strategy within an overall education sector strategy. To start with, the authors provide an answer to the questions "What is…
Acid Rain. LC Science Tracer Bullet.
ERIC Educational Resources Information Center
Hollmann, Pauline, Comp.
The term "acid rain," also called "acid precipitation," generally refers to any precipitation having a pH value of less than 5.6. This guide to the literature on acid rain in the collections of the Library of Congress is not necessarily intended to be a comprehensive bibliography. It is designed to provide the reader with a set…
Ice-Accretion Scaling Using Water-Film Thickness Parameters
NASA Technical Reports Server (NTRS)
Anderson, David N.; Feo, Alejandro
2003-01-01
Studies were performed at INTA in Spain to determine water-film thickness on a stagnation-point probe inserted in a simulated cloud. The measurements were correlated with non-dimensional parameters describing the flow and the cloud conditions. Icing scaling tests in the NASA Glenn Icing Research Tunnel were then conducted using the Ruff scaling method with the scale velocity found by matching scale and reference values of either the INTA non-dimensional water-film thickness or a Weber number based on that film thickness. For comparison, tests were also performed using the constant drop-size Weber number and the average-velocity methods. The reference and scale models were both aluminum, 61-cm-span, NACA 0012 airfoil sections at 0 deg. AOA. The reference had a 53-cm-chord and the scale, 27 cm (1/2 size). Both models were mounted vertically in the center of the IRT test section. Tests covered a freezing fraction range of 0.28 to 1.0. Rime ice (n = 1.0) tests showed the consistency of the IRT calibration over a range of velocities. At a freezing fraction of 0.76, there was no significant difference in the scale ice shapes produced by the different methods. For freezing fractions of 0.40, 0.52 and 0.61, somewhat better agreement with the reference horn angles was typically achieved with the average-velocity and constant-film thickness methods than when either of the two Weber numbers was matched to the reference value. At a freezing fraction of 0.28, the four methods were judged equal in providing simulations of the reference shape.
A modified Galam’s model for word-of-mouth information exchange
NASA Astrophysics Data System (ADS)
Ellero, Andrea; Fasano, Giovanni; Sorato, Annamaria
2009-09-01
In this paper we analyze the stochastic model proposed by Galam in [S. Galam, Modelling rumors: The no plane Pentagon French hoax case, Physica A 320 (2003), 571-580], for information spreading in a ‘word-of-mouth’ process among agents, based on a majority rule. Using the communications rules among agents defined in the above reference, we first perform simulations of the ‘word-of-mouth’ process and compare the results with the theoretical values predicted by Galam’s model. Some dissimilarities arise in particular when a small number of agents is considered. We find motivations for these dissimilarities and suggest some enhancements by introducing a new parameter dependent model. We propose a modified Galam’s scheme which is asymptotically coincident with the original model in the above reference. Furthermore, for relatively small values of the parameter, we provide a numerical experience proving that the modified model often outperforms the original one.
Systems and methods for predicting materials properties
Ceder, Gerbrand; Fischer, Chris; Tibbetts, Kevin; Morgan, Dane; Curtarolo, Stefano
2007-11-06
Systems and methods for predicting features of materials of interest. Reference data are analyzed to deduce relationships between the input data sets and output data sets. Reference data includes measured values and/or computed values. The deduced relationships can be specified as equations, correspondences, and/or algorithmic processes that produce appropriate output data when suitable input data is used. In some instances, the output data set is a subset of the input data set, and computational results may be refined by optionally iterating the computational procedure. To deduce features of a new material of interest, a computed or measured input property of the material is provided to an equation, correspondence, or algorithmic procedure previously deduced, and an output is obtained. In some instances, the output is iteratively refined. In some instances, new features deduced for the material of interest are added to a database of input and output data for known materials.
Advanced Life Support Research and Technology Development Metric
NASA Technical Reports Server (NTRS)
Hanford, A. J.
2004-01-01
The Metric is one of several measures employed by the NASA to assess the Agency s progress as mandated by the United States Congress and the Office of Management and Budget. Because any measure must have a reference point, whether explicitly defined or implied, the Metric is a comparison between a selected ALS Project life support system and an equivalently detailed life support system using technology from the Environmental Control and Life Support System (ECLSS) for the International Space Station (ISS). This document provides the official calculation of the Advanced Life Support (ALS) Research and Technology Development Metric (the Metric) for Fiscal Year 2004. The values are primarily based on Systems Integration, Modeling, and Analysis (SIMA) Element approved software tools or reviewed and approved reference documents. For Fiscal Year 2004, the Advanced Life Support Research and Technology Development Metric value is 2.03 for an Orbiting Research Facility and 1.62 for an Independent Exploration Mission.
Towards a new tool for the evaluation of the quality of ultrasound compressed images.
Delgorge, Cécile; Rosenberger, Christophe; Poisson, Gérard; Vieyres, Pierre
2006-11-01
This paper presents a new tool for the evaluation of ultrasound image compression. The goal is to measure the image quality as easily as with a statistical criterion, and with the same reliability as the one provided by the medical assessment. An initial experiment is proposed to medical experts and represents our reference value for the comparison of evaluation criteria. Twenty-one statistical criteria are selected from the literature. A cumulative absolute similarity measure is defined as a distance between the criterion to evaluate and the reference value. A first fusion method based on a linear combination of criteria is proposed to improve the results obtained by each of them separately. The second proposed approach combines different statistical criteria and uses the medical assessment in a training phase with a support vector machine. Some experimental results are given and show the benefit of fusion.
Iversen, B S; Sabbioni, E; Fortaner, S; Pietra, R; Nicolotti, A
2003-01-20
Statistical data treatment is a key point in the assessment of trace element reference values being the conclusive stage of a comprehensive and organized evaluation process of metal concentration in human body fluids. The EURO TERVIHT project (Trace Elements Reference Values in Human Tissues) was started for evaluating, checking and suggesting harmonized procedures for the establishment of trace element reference intervals in body fluids and tissues. Unfortunately, different statistical approaches are being used in this research field making data comparison difficult and in some cases impossible. Although international organizations such as International Federation of Clinical Chemistry (IFCC) or International Union of Pure and Applied Chemistry (IUPAC) have issued recommended guidelines for reference values assessment, including the statistical data treatment, a unique format and a standardized data layout is still missing. The aim of the present study is to present a software (BioReVa) running under Microsoft Windows platform suitable for calculating the reference intervals of trace elements in body matrices. The main scope for creating an ease-of-use application was to control the data distribution, to establish the reference intervals according to the accepted recommendation, on the base of the simple statistic, to get a standard presentation of experimental data and to have an application to which further need could be integrated in future. BioReVa calculates the IFCC reference intervals as well as the coverage intervals recommended by IUPAC as a supplement to the IFCC intervals. Examples of reference values and reference intervals calculated with BioReVa software concern Pb and Se in blood; Cd, In and Cr in urine, Hg and Mo in hair of different general European populations. University of Michigan
Hand bone mineral density reference values in a Turkish healthy female population.
Alioglu, Kenan; Dogu, Beril; Sirzai, Hulya; Yilmaz, Figen; Kuran, Banu
2017-12-01
In this study we aimed at identifying the bone mineral density (BMD) reference values of hands, according to age, measured by dual-energy X-ray absorptiometry (DEXA) and assessing the correlation of these values with lumbar and femoral BMD values. A total of 403 healthy women aged between 20 and 70 participated in our study. All BMD measurements are performed by DEXA method on both hands, anteroposterior lumbar spine (L2-L4) and right femur (femoral neck, total femur) regions. BMD results of all the patients were divided to 10-year age categories and evaluated in five subgroups in total (20-30 to 61-70). Among the 10-year age categories we found both dominant and non-dominant hand peak bone mass values in the 31-40 years age group (0.423 ± 0.039 g/cm², 0.410 ± 0.043 g/cm², respectively). Statistically significant positive correlation was defined between dominant and non-dominant hand BMD values and L2-L4 spine, femur neck and total femur values (for dominant hand r = 0.636, P = 0.0001; r = 0.645, P = 0.0001; r = 0.623; P = 0.0001; for non-dominant hand r = 0.624, P = 0.0001; r = 0.637, P = 0.0001, r = 0.623, P = 0.0001, respectively). Regarding the relationship of age and menopause with BMD results, a negative statistical relationship was observed among dominant and non-dominant hand, L2-L4 spine, femoral neck and total femur BMD values (P = 0.0001). Our study has provided hand BMD reference values in women aged between 20-70 years; further studies are needed to investigate the role of these values in identifying diseases causing osteoporosis in the hand and in evaluating treatment. © 2013 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.
Haeckel, Rainer; Hänecke, Petra
2003-07-01
The comparability between glucose concentrations measured in various sample systems is still a matter of debate. Decision limits are usually determined in venous plasma and then converted to either blood or to the aqueous compartment (activity). The conversion factors recommended have not yet been generally accepted. In the present study, glucose concentrations were determined in blood and plasma with an Ebio analyser (molarity) and in the aqueous compartment with both an EML 105 and an Omni (molality). All analytical results were referred to the same aqueous standard solution. The Ebio results agreed with reference method values in control materials. Concentrations determined in the various sample systems from patients (molarity) correlated well with the molality values measured either with the EML or the Omni. However, the mean values of the EML were not consistent with those derived theoretically by considering the different water content. With the Omni, only molality values in whole blood appeared plausible, but not in plasma, although the two sample systems should provide identical molality values. The EML results were almost identical in whole blood and plasma. Theoretically, glucose molality would be the ideal diagnostic quantity. However, no diagnostic advantage of molality determined in whole blood with the Omni vs. molarity values could be detected in a group of 40 non-diabetic and 27 diabetic subjects.
Brown, Kerry A; de Wit, Liesbeth; Timotijevic, Lada; Sonne, Anne-Mette; Lähteenmäki, Liisa; Brito Garcia, Noé; Jeruszka-Bielak, Marta; Sicińska, Ewa; Moore, Alana N; Lawrence, Mark; Raats, Monique M
2015-06-01
Transparent evidence-based decision making has been promoted worldwide to engender trust in science and policy making. Yet, little attention has been given to transparency implementation. The degree of transparency (focused on how uncertain evidence was handled) during the development of folate and vitamin D Dietary Reference Values was explored in three a priori defined areas: (i) value request; (ii) evidence evaluation; and (iii) final values. Qualitative case studies (semi-structured interviews and desk research). A common protocol was used for data collection, interview thematic analysis and reporting. Results were coordinated via cross-case synthesis. Australia and New Zealand, Netherlands, Nordic countries, Poland, Spain and UK. Twenty-one interviews were conducted in six case studies. Transparency of process was not universally observed across countries or areas of the recommendation setting process. Transparency practices were most commonly seen surrounding the request to develop reference values (e.g. access to risk manager/assessor problem formulation discussions) and evidence evaluation (e.g. disclosure of risk assessor data sourcing/evaluation protocols). Fewer transparency practices were observed to assist with handling uncertainty in the evidence base during the development of quantitative reference values. Implementation of transparency policies may be limited by a lack of dedicated resources and best practice procedures, particularly to assist with the latter stages of reference value development. Challenges remain regarding the best practice for transparently communicating the influence of uncertain evidence on the final reference values. Resolving this issue may assist the evolution of nutrition risk assessment and better inform the recommendation setting process.
Pottel, Hans; Hoste, Liesbeth; Delanaye, Pierre
2015-05-01
The chronic kidney disease (CKD) classification system for children is similar to that for adults, with both mainly based on estimated glomerular filtration rate (eGFR) combined with fixed cut-off values. The main cut-off eGFR value used to define CKD is 60 mL/min/1.73 m(2), a value that is also applied for children older than 2 years of age, adolescents and young adults. Based on a literature search, we evaluated inclusion criteria for eGFR in clinical trials or research studies on CKD for children. We also collected information on direct measurements of GFR (mGFR) in children and adolescents, with the aim to estimate the normal reference range for GFR. Using serum creatinine (Scr) normal reference values and Scr-based eGFR-equations, we also evaluated the correspondence between Scr normal reference values and (e)GFR normal reference values. Based on our literature search, the inclusion of children in published CKD studies has been based on cut-off values for eGFR of >60 mL/min/1.73 m(2). The lower reference limits for mGFR far exceed this adult threshold. Using eGFR values calculated using Scr-based formulas, we found that abnormal Scr levels in children already correspond to eGFR values that are below a cut-off of 75 mL/min/1.73 m(2). Abnormal GFR in children, adolescents and young adults starts below 75 mL/min/1.73 m(2), and as abnormality is a sign of disease, we recommend referring children, adolescents and young adults with an (e)GFR of <75 mL/min/1.73 m(2) for further clinical assessment.
Srivastava, Abneesh; Michael Verkouteren, R
2018-07-01
Isotope ratio measurements have been conducted on a series of isotopically distinct pure CO 2 gas samples using the technique of dual-inlet isotope ratio mass spectrometry (DI-IRMS). The influence of instrumental parameters, data normalization schemes on the metrological traceability and uncertainty of the sample isotope composition have been characterized. Traceability to the Vienna PeeDee Belemnite(VPDB)-CO 2 scale was realized using the pure CO 2 isotope reference materials(IRMs) 8562, 8563, and 8564. The uncertainty analyses include contributions associated with the values of iRMs and the repeatability and reproducibility of our measurements. Our DI-IRMS measurement system is demonstrated to have high long-term stability, approaching a precision of 0.001 parts-per-thousand for the 45/44 and 46/44 ion signal ratios. The single- and two-point normalization bias for the iRMs were found to be within their published standard uncertainty values. The values of 13 C/ 12 C and 18 O/ 16 O isotope ratios are expressed relative to VPDB-CO 2 using the [Formula: see text] and [Formula: see text] notation, respectively, in parts-per-thousand (‰ or per mil). For the samples, value assignments between (-25 to +2) ‰ and (-33 to -1) ‰ with nominal combined standard uncertainties of (0.05, 0.3) ‰ for [Formula: see text] and [Formula: see text], respectively were obtained. These samples are used as laboratory reference to provide anchor points for value assignment of isotope ratios (with VPDB traceability) to pure CO 2 samples. Additionally, they serve as potential parent isotopic source material required for the development of gravimetric based iRMs of CO 2 in CO 2 -free dry air in high pressure gas cylinder packages at desired abundance levels and isotopic composition values. Graphical abstract CO 2 gas isotope ratio metrology.
Heine, Henry S.; England, Marilyn J.; Waag, David M.; Byrne, W. Russell
2001-01-01
In vitro susceptibilities to 28 antibiotics were determined for 11 strains of Burkholderia mallei by the broth microdilution method. The B. mallei strains demonstrated susceptibility to aminoglycosides, macrolides, quinolones, doxycycline, piperacillin, ceftazidime, and imipenem. For comparison and evaluation, 17 antibiotic susceptibilities were also determined by the E-test. E-test values were always lower than the broth dilution values. Establishing and comparing antibiotic susceptibilities of specific B. mallei strains will provide reference information for assessing new antibiotic agents. PMID:11408233
NASA Astrophysics Data System (ADS)
Yue, Chongfeng; Bai, Lu; Hong, Yicheng; Xu, Lijun
2018-03-01
The high purity and high quality direct reduced iron(DRI) products which were produced by high grade and high quality iron powder, with a high grade and low impurity characteristics. This article introduced the application of high purity and high quality DRI in the fields of amorphous base material, atomized iron powder, powder superalloy, high purity and ultra-low carbon special metallurgy products, precision casting, super alloy and various iron-based alloys. It provides a reference for the high added value utilization of DRI.
Schlenz, H; Intemann, T; Wolters, M; González-Gil, E M; Nappo, A; Fraterman, A; Veidebaum, T; Molnar, D; Tornaritis, M; Sioen, I; Mårild, S; Iacoviello, L; Ahrens, W
2014-09-01
C-reactive protein (CRP) is involved in a wide range of diseases. It is a powerful marker for inflammatory processes used for diagnostic and monitoring purposes. We aimed to establish reference values as data on the distribution of serum CRP levels in young European children are scarce. Reference values of high-sensitivity CRP concentrations were calculated for 9855 children aged 2.0-10.9 years, stratified by age and sex. The children were recruited during the population-based European IDEFICS study (Identification and prevention of Dietary- and lifestyle-induced health Effects in Children and infantS) with 18 745 participants recruited from 2007 to 2010. In 44.1% of the children, CRP values were below or equal the detection limit of 0.2 mg/l. Median CRP concentrations showed a slight negative age trend in boys and girls, whereas serum CRP values were slightly higher in girls than in boys across all age groups. Our population-based reference values of CRP may guide paediatric practice as elevated values may require further investigation or treatment. Therefore, the presented reference values represent a basis for clinical evaluation and for future research on risk assessment of diseases associated with increased CRP levels among children.
Finance for practicing radiologists.
Berlin, Jonathan W; Lexa, Frank James
2005-03-01
This article reviews basic finance for radiologists. Using the example of a hypothetical outpatient computed tomography center, readers are introduced to the concept of net present value. This concept refers to the current real value of anticipated income in the future, realizing that revenue in the future has less value than it does today. Positive net present value projects add wealth to a practice and should be pursued. The article details how costs and revenues for a hypothetical outpatient computed tomography center are determined and elucidates the difference between fixed costs and variable costs. The article provides readers with the steps used to calculate the break-even volume for an outpatient computed tomography center given situation-specific assumptions regarding staff, equipment lease rates, rent, and third-party payer mix.
Barczi, Jean-François; Rey, Hervé; Caraglio, Yves; de Reffye, Philippe; Barthélémy, Daniel; Dong, Qiao Xue; Fourcaud, Thierry
2008-05-01
AmapSim is a tool that implements a structural plant growth model based on a botanical theory and simulates plant morphogenesis to produce accurate, complex and detailed plant architectures. This software is the result of more than a decade of research and development devoted to plant architecture. New advances in the software development have yielded plug-in external functions that open up the simulator to functional processes. The simulation of plant topology is based on the growth of a set of virtual buds whose activity is modelled using stochastic processes. The geometry of the resulting axes is modelled by simple descriptive functions. The potential growth of each bud is represented by means of a numerical value called physiological age, which controls the value for each parameter in the model. The set of possible values for physiological ages is called the reference axis. In order to mimic morphological and architectural metamorphosis, the value allocated for the physiological age of buds evolves along this reference axis according to an oriented finite state automaton whose occupation and transition law follows a semi-Markovian function. Simulations were performed on tomato plants to demonstrate how the AmapSim simulator can interface external modules, e.g. a GREENLAB growth model and a radiosity model. The algorithmic ability provided by AmapSim, e.g. the reference axis, enables unified control to be exercised over plant development parameter values, depending on the biological process target: how to affect the local pertinent process, i.e. the pertinent parameter(s), while keeping the rest unchanged. This opening up to external functions also offers a broadened field of applications and thus allows feedback between plant growth and the physical environment.
Barczi, Jean-François; Rey, Hervé; Caraglio, Yves; de Reffye, Philippe; Barthélémy, Daniel; Dong, Qiao Xue; Fourcaud, Thierry
2008-01-01
Background and Aims AmapSim is a tool that implements a structural plant growth model based on a botanical theory and simulates plant morphogenesis to produce accurate, complex and detailed plant architectures. This software is the result of more than a decade of research and development devoted to plant architecture. New advances in the software development have yielded plug-in external functions that open up the simulator to functional processes. Methods The simulation of plant topology is based on the growth of a set of virtual buds whose activity is modelled using stochastic processes. The geometry of the resulting axes is modelled by simple descriptive functions. The potential growth of each bud is represented by means of a numerical value called physiological age, which controls the value for each parameter in the model. The set of possible values for physiological ages is called the reference axis. In order to mimic morphological and architectural metamorphosis, the value allocated for the physiological age of buds evolves along this reference axis according to an oriented finite state automaton whose occupation and transition law follows a semi-Markovian function. Key Results Simulations were performed on tomato plants to demostrate how the AmapSim simulator can interface external modules, e.g. a GREENLAB growth model and a radiosity model. Conclusions The algorithmic ability provided by AmapSim, e.g. the reference axis, enables unified control to be exercised over plant development parameter values, depending on the biological process target: how to affect the local pertinent process, i.e. the pertinent parameter(s), while keeping the rest unchanged. This opening up to external functions also offers a broadened field of applications and thus allows feedback between plant growth and the physical environment. PMID:17766310
Voigt, M; Olbertz, D; Hentschel, R; Kunze, M; Hagenah, H-P; Scholz, R; Wittwer-Backofen, U; Hesse, V; Straube, S
2016-04-01
We aimed to develop national reference values for birth weight, length, head circumference, and weight for length for newborn triplets based on data from the German perinatal survey of 2007-2011. Perinatal survey data of 3,690 newborn triplets from all the states of Germany were kindly provided to us by the AQUA Institute in Göttingen, Germany. Data of 3,567 newborn triplets were included in the analyses. Sex-specific percentile values were calculated using cumulative frequencies. Percentile values at birth were computed for the 3rd, 10th, 25th, 50th, 75th, 90th, and 97th percentiles for 21-36 completed weeks of gestation. We present the first German reference values (tables and curves) for the anthropometric dimensions of triplet neonates and compare selected birth weight and length percentiles of triplets (after 32 and 34 completed weeks of gestation) to those of singletons and twins. The differences in the 50th birth weight percentiles between singletons and triplets after 32 completed weeks of gestation were 180 g for girls and 210 g for boys; after 34 weeks of gestation the differences were 320 and 325 g, respectively. The differences between twins and triplets after 32 weeks of gestation were 100 g for girls and 120 g for boys; after 34 weeks of gestation they were 130 and 135 g, respectively. The data presented here enable the classification of newborn triplets according to somatic parameters making reference to German perinatal data. © Georg Thieme Verlag KG Stuttgart · New York.
[Diagnostic reference levels in interventional radiology].
Vañó Carruana, E; Fernández Soto, J M; Sánchez Casanueva, R M; Ten Morón, J I
2013-12-01
This article discusses the diagnostic reference levels for radiation exposure proposed by the International Commission on Radiological Protection (ICRP) to facilitate the application of the optimization criteria in diagnostic imaging and interventional procedures. These levels are normally established as the third quartile of the dose distributions to patients in an ample sample of centers and are supposed to be representative of good practice regarding patient exposure. In determining these levels, it is important to evaluate image quality as well to ensure that it is sufficient for diagnostic purposes. When the values for the dose received by patients are systematically higher or much lower than the reference levels, an investigation should determine whether corrective measures need to be applied. The European and Spanish regulations require the use of these reference values in quality assurance programs. For interventional procedures, the dose area product (or kerma area product) values are usually used as reference values together with the time under fluoroscopy and the total number of images acquired. The most modern imaging devices allow the value of the accumulated dose at the entrance to the patient to be calculated to optimize the distribution of the dose on the skin. The ICRP recommends that the complexity of interventional procedures be taken into account when establishing reference levels. In the future, diagnostic imaging departments will have automatic systems to manage patient dosimetric data; these systems will enable continuous dosage auditing and alerts about individual procedures that might involve doses several times above the reference values. This article also discusses aspects that need to be clarified to take better advantage of the reference levels in interventional procedures. Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.
Physician awareness of enhanced prenatal services for medicaid-insured pregnant women.
Raffo, Jennifer E; Gary, Monica; Forde, Gareth K; Meghea, Cristian I; Roman, Lee Anne
2014-01-01
Medicaid enhanced prenatal service (EPS) programs, including care coordination, were developed to improve birth outcomes for low-income pregnant women. In Michigan, less than a third of eligible pregnant women are enrolled in services. Physician or medical clinics provide referrals to community-based EPS. The objective of this study was to examine physician knowledge and perceptions of EPS. A cross-sectional survey of obstetric providers was conducted in 2009. A questionnaire was created to assess understanding of the EPS program. The study was conducted in an urban Michigan community. Participants included a convenience sample (N = 56) of community Obstetrics and Gynecology attending physicians and resident physicians within a single, large health system. Outcome measures included knowledge of the program and patient participation, referral practices, perceptions of the program, value for patients and providers, appropriateness of physicians to provide program referrals, and barriers to referring. Findings indicated that most physicians (84%) had little familiarity with EPS, 60% did not personally refer to EPS, 54% did not know whether other office staff referred to EPS, and 65% were unaware whether their patients received EPS. Yet, more than 90% of physicians reported that EPS would benefit their patients and believed that it was appropriate for them to refer all their eligible patients. Further efforts should be made to better understand how physicians and EPS providers could function together on behalf of patients. Statewide Medicaid-sponsored EPS programs could serve as a valuable patient and physician resource for psychosocial risk screening, care management, education, and referral support if better utilized.
Kodama, Ayuto; Kume, Yu; Tsugaruya, Megumi; Ishikawa, Takashi
2016-01-01
The circadian rhythm in older adults is commonly known to change with a decrease in physical activity. However, the association between circadian rhythm metrics and physical activity remains unclear. The objective of this study was to examine circadian activity patterns in older people with and without dementia and to determine the amount of physical activity conducive to a good circadian measurement. Circadian parameters were collected from 117 older community-dwelling people (66 subjects without dementia and 52 subjects with dementia); the parameters were measured continuously using actigraphy for 7 days. A receiver operating characteristic (ROC) curve was applied to determine reference values for the circadian rhythm parameters, consisting of interdaily stability (IS), intradaily variability (IV), and relative amplitude (RA), in older subjects. The ROC curve revealed reference values of 0.55 for IS, 1.10 for IV, and 0.82 for RA. In addition, as a result of the ROC curve in the moderate-to-vigorous physical Activity (MVPA) conducive to the reference value of the Non-parametric Circadian Rhythm Analysis per day, the optimal reference values were 51 minutes for IV and 55 minutes for RA. However, the IS had no classification accuracy. Our results demonstrated the reference values derived from the circadian parameters of older Japanese population with or without dementia. Also, we determined the MVPA conducive to a good circadian rest-active pattern. This reference value for physical activity conducive to a good circadian rhythm might be useful for developing a new index for health promotion in the older community-dwelling population.
[Reference values for lead levels in blood for the urban population].
Paolielo, M M; Gutierrez, P R; Turini, C A; Matsuo, T; Mezzaroba, L; Barbosa, D S; Alvarenga, A L; Carvalho, S R; Figueiroa, G A; Leite, V G; Gutierrez, A C; Nogueira, K B; Inamine, W A; Zavatti, A M
1997-04-01
The lead reference values for blood used in Brazil come from studies conducted in other countries, where socioeconomic, clinical, nutritional and occupational conditions are significantly different. In order to guarantee an accurate biomonitoring of the population which is occupationally exposed to lead, a major health concern of the studied community, reference values for individuals who are not occupationally exposed and who live in the southern region of the city were established. The sample was composed of 206 subjects of at least 15 years of age. Various strategies were employed to assure good-quality sampling. Subjects who presented values outside clinical or laboratory norms were excluded, as well as those whose specific activities might interfere with the results. Lead reference values for blood were found to be from 2.40 to 16.6 micrograms.dL-1, obtained by the interval x +/- 2s (where x is the mean and s is the standard deviation form observed values) and the median was 7.9 micrograms.dL-1.
Biometric Subject Verification Based on Electrocardiographic Signals
NASA Technical Reports Server (NTRS)
Dusan, Sorin V. (Inventor); Jorgensen, Charles C. (Inventor)
2014-01-01
A method of authenticating or declining to authenticate an asserted identity of a candidate-person. In an enrollment phase, a reference PQRST heart action graph is provided or constructed from information obtained from a plurality of graphs that resemble each other for a known reference person, using a first graph comparison metric. In a verification phase, a candidate-person asserts his/her identity and presents a plurality of his/her heart cycle graphs. If a sufficient number of the candidate-person's measured graphs resemble each other, a representative composite graph is constructed from the candidate-person's graphs and is compared with a composite reference graph, for the person whose identity is asserted, using a second graph comparison metric. When the second metric value lies in a selected range, the candidate-person's assertion of identity is accepted.
Misuse of ultrasound for palpable undescended testis by primary care providers: A prospective study
Wong, Nathan C.; Bansal, Rahul K.; Lorenzo, Armando J.; DeMaria, Jorge; Braga, Luis H.
2015-01-01
Introduction: Although previous evidence has shown that ultrasound is unreliable to diagnose undescended testis, many primary care providers (PCP) continue to misuse it. We assessed the performance of ultrasound as a diagnostic tool for palpable undescended testis, as well as the diagnostic agreement between PCP and pediatric urologists. Methods: We performed a prospective observational cohort study between 2011 and 2013 for consecutive boys referred with a diagnosis of undescended testis to our tertiary pediatric hospital. Patients referred without an ultrasound and those with non-palpable testes were excluded. Data on referring diagnosis, pediatric urology examination and ultrasound reports were analyzed. Results: Our study consisted of 339 boys. Of these, patients without an ultrasound (n = 132) and those with non-palpable testes (n = 38) were excluded. In the end, there were 169 pateints in this study. Ultrasound was performed in 50% of referred boys showing 256 undescended testis. The mean age at time of referral was 45 months. When ultrasound was compared to physical examination by the pediatric urologist, agreement was only 34%. The performance of ultrasound for palpable undescended testis was: sensitivity = 100%; specificity = 16%; positive predictive value = 34%; negative predictive value = 100%; positive likelihood ratio = 1.2; and negative likelihood ratio = 0. Diagnosis of undescended testis by PCP was confirmed by physical examination in 30% of cases, with 70% re-diagnosed with normal or retractile testes. Conclusion: Ultrasound performed poorly to assess for palpable undescended testis in boys and should not be used. Although the study has important limitations, there is an increasing need for education and evidence-based guidelines for PCP in the management of undescended testis. PMID:26788226
Ruediger, T M; Allison, S C; Moore, J M; Wainner, R S
2014-09-01
The purposes of this descriptive and exploratory study were to examine electrophysiological measures of ulnar sensory nerve function in disease free adults to determine reliability, determine reference values computed with appropriate statistical methods, and examine predictive ability of anthropometric variables. Antidromic sensory nerve conduction studies of the ulnar nerve using surface electrodes were performed on 100 volunteers. Reference values were computed from optimally transformed data. Reliability was computed from 30 subjects. Multiple linear regression models were constructed from four predictor variables. Reliability was greater than 0.85 for all paired measures. Responses were elicited in all subjects; reference values for sensory nerve action potential (SNAP) amplitude from above elbow stimulation are 3.3 μV and decrement across-elbow less than 46%. No single predictor variable accounted for more than 15% of the variance in the response. Electrophysiologic measures of the ulnar sensory nerve are reliable. Absent SNAP responses are inconsistent with disease free individuals. Reference values recommended in this report are based on appropriate transformations of non-normally distributed data. No strong statistical model of prediction could be derived from the limited set of predictor variables. Reliability analyses combined with relatively low level of measurement error suggest that ulnar sensory reference values may be used with confidence. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Varrone, Andrea; Gulyás, Balázs; Takano, Akihiro; Stabin, Michael G; Jonsson, Cathrine; Halldin, Christer
2012-02-01
[(18)F]FE-PE2I is a promising dopamine transporter (DAT) radioligand. In nonhuman primates, we examined the accuracy of simplified quantification methods and the estimates of radiation dose of [(18)F]FE-PE2I. In the quantification study, binding potential (BP(ND)) values previously reported in three rhesus monkeys using kinetic and graphical analyses of [(18)F]FE-PE2I were used for comparison. BP(ND) using the cerebellum as reference region was obtained with four reference tissue methods applied to the [(18)F]FE-PE2I data that were compared with the kinetic and graphical analyses. In the whole-body study, estimates of adsorbed radiation were obtained in two cynomolgus monkeys. All reference tissue methods provided BP(ND) values within 5% of the values obtained with the kinetic and graphical analyses. The shortest imaging time for stable BP(ND) estimation was 54 min. The average effective dose of [(18)F]FE-PE2I was 0.021 mSv/MBq, similar to 2-deoxy-2-[(18)F]fluoro-d-glucose. The results in nonhuman primates suggest that [(18)F]FE-PE2I is suitable for accurate and stable DAT quantification, and its radiation dose estimates would allow for a maximal administered radioactivity of 476 MBq in human subjects. Copyright © 2012 Elsevier Inc. All rights reserved.
Lejarraga, Horacio; del Pino, Mariana; Fano, Virginia; Caino, Silvia; Cole, Timothy J
2009-04-01
Argentine growth references have been widely used by paediatricians in the country for the last 20 years. Two main difficulties were detected during this period: the lack of data on breast-fed children in the first months of age, and problems in the calculation of "z" scores. On these basis, local data on weight and height during the first two years of life were replaced by data from the longitudinal international study recently carried out by WHO. L, M and S values were obtained from the original percentile data for ages 2 to maturity, and smoothed with cubic splines. Selected percentiles for weight and height from birth to maturity were then re-calculated using LMS values. Charts were designed in two formats: birth to maturity and birth to 6.0 years. Now, users can calculate "z" scores automatically at the new site provided by the Department of Growth and Development, Hospital Garrahan, which enables the use of the LMS growth programme. We have also incorporated into the new charts, percentiles of the age of attaining menarche and Tanner s stage II of breast, genitalia and pubic hair for Argentine children. We think the new references represent an improvement in the assessment of growth in our country.
Spinelli, L.; Botwicz, M.; Zolek, N.; Kacprzak, M.; Milej, D.; Sawosz, P.; Liebert, A.; Weigel, U.; Durduran, T.; Foschum, F.; Kienle, A.; Baribeau, F.; Leclair, S.; Bouchard, J.-P.; Noiseux, I.; Gallant, P.; Mermut, O.; Farina, A.; Pifferi, A.; Torricelli, A.; Cubeddu, R.; Ho, H.-C.; Mazurenka, M.; Wabnitz, H.; Klauenberg, K.; Bodnar, O.; Elster, C.; Bénazech-Lavoué, M.; Bérubé-Lauzière, Y.; Lesage, F.; Khoptyar, D.; Subash, A. A.; Andersson-Engels, S.; Di Ninni, P.; Martelli, F.; Zaccanti, G.
2014-01-01
A multi-center study has been set up to accurately characterize the optical properties of diffusive liquid phantoms based on Intralipid and India ink at near-infrared (NIR) wavelengths. Nine research laboratories from six countries adopting different measurement techniques, instrumental set-ups, and data analysis methods determined at their best the optical properties and relative uncertainties of diffusive dilutions prepared with common samples of the two compounds. By exploiting a suitable statistical model, comprehensive reference values at three NIR wavelengths for the intrinsic absorption coefficient of India ink and the intrinsic reduced scattering coefficient of Intralipid-20% were determined with an uncertainty of about 2% or better, depending on the wavelength considered, and 1%, respectively. Even if in this study we focused on particular batches of India ink and Intralipid, the reference values determined here represent a solid and useful starting point for preparing diffusive liquid phantoms with accurately defined optical properties. Furthermore, due to the ready availability, low cost, long-term stability and batch-to-batch reproducibility of these compounds, they provide a unique fundamental tool for the calibration and performance assessment of diffuse optical spectroscopy instrumentation intended to be used in laboratory or clinical environment. Finally, the collaborative work presented here demonstrates that the accuracy level attained in this work for optical properties of diffusive phantoms is reliable. PMID:25071947
[European community guidelines and standards in indoor air quality: what proposals for Italy].
Settimo, Gaetano; D'Alessandro, Daniela
2014-01-01
Indoor air quality is an issue on which to focus because of the increasing number of exposed population and in view of the strong public feeling on this issue. This paper reports the rules of EU and several European countries about indoor air quality, focusing on the initiatives performed in Italy to respond to WHO recommendations. Several EU countries have introduced in their legislation rules relating to indoor air quality. At the moment, in Italy, a reference rule has not been issued. For this reason, up to date main informations concerning some guidelines or reference values in indoor air, to be used for a first comparison, are those obtained by the scientific literature, or by the guidelines issued by other European countries or, for analogy, by other standard values such as limit or reference values regarding outdoor air. Even the EU, while reaffirming the priority of energy efficiency measures, recommends healthier indoor environments and the development of a specific European strategy on the issue of indoor air quality. The National Study Group on indoor pollution of the Italian National Health Institute (ISS), is working for the development of shared technical and scientific documents, in order to provide greater uniformity of actions at national level, waiting for a legal framework for indoor air quality, in the light of the indication already produced by the WHO.
A small number of candidate gene SNPs reveal continental ancestry in African Americans
KODAMAN, NURI; ALDRICH, MELINDA C.; SMITH, JEFFREY R.; SIGNORELLO, LISA B.; BRADLEY, KEVIN; BREYER, JOAN; COHEN, SARAH S.; LONG, JIRONG; CAI, QIUYIN; GILES, JUSTIN; BUSH, WILLIAM S.; BLOT, WILLIAM J.; MATTHEWS, CHARLES E.; WILLIAMS, SCOTT M.
2013-01-01
SUMMARY Using genetic data from an obesity candidate gene study of self-reported African Americans and European Americans, we investigated the number of Ancestry Informative Markers (AIMs) and candidate gene SNPs necessary to infer continental ancestry. Proportions of African and European ancestry were assessed with STRUCTURE (K=2), using 276 AIMs. These reference values were compared to estimates derived using 120, 60, 30, and 15 SNP subsets randomly chosen from the 276 AIMs and from 1144 SNPs in 44 candidate genes. All subsets generated estimates of ancestry consistent with the reference estimates, with mean correlations greater than 0.99 for all subsets of AIMs, and mean correlations of 0.99±0.003; 0.98± 0.01; 0.93±0.03; and 0.81± 0.11 for subsets of 120, 60, 30, and 15 candidate gene SNPs, respectively. Among African Americans, the median absolute difference from reference African ancestry values ranged from 0.01 to 0.03 for the four AIMs subsets and from 0.03 to 0.09 for the four candidate gene SNP subsets. Furthermore, YRI/CEU Fst values provided a metric to predict the performance of candidate gene SNPs. Our results demonstrate that a small number of SNPs randomly selected from candidate genes can be used to estimate admixture proportions in African Americans reliably. PMID:23278390
NASA Astrophysics Data System (ADS)
Ding, Liang; Wang, Shui; Cai, Bingjie; Zhang, Mancheng; Qu, Changsheng
2018-02-01
In this study, portable X-ray fluorescence spectrometry (pXRF) was used to measure the heavy metal contents of As, Cu, Cr, Ni, Pb and Zn in the soils of heavy metal-contaminated sites. The precision, accuracy and system errors of pXRF were evaluated and compared with traditional laboratory methods to examine the suitability of in situ pXRF. The results show that the pXRF analysis achieved satisfactory accuracy and precision in measuring As, Cr, Cu, Ni, Pb, and Zn in soils, and meets the requirements of the relevant detection technology specifications. For the certified reference soil samples, the pXRF results of As, Cr, Cu, Ni, Pb, and Zn show good linear relationships and coefficients of determination with the values measured using the reference analysis methods; with the exception of Ni, all the measured values were within the 95% confidence level. In the soil samples, the coefficients of determination between Cu, Zn, Pb, and Ni concentrations measured laboratory pXRF and the values measured with laboratory analysis all reach 0.9, showing a good linear relationship; however, there were large deviations between methods for Cr and As. This study provides reference data and scientific support for rapid detection of heavy metals in soils using pXRF in site investigation, which can better guide the practical application of pXRF.
NASA Astrophysics Data System (ADS)
Janssen, Christof; Elandaloussi, Hadj; Gröbner, Julian
2018-03-01
The room temperature (294.09 K) absorption cross section of ozone at the 325 nm HeCd wavelength has been determined under careful consideration of possible biases. At the vacuum wavelength of 325.126 nm, thus in a region used by a variety of ozone remote sensing techniques, an absorption cross-section value of σ = 16.470×10-21 cm2 was measured. The measurement provides the currently most accurate direct photometric absorption value of ozone in the UV with an expanded (coverage factor k = 2) standard uncertainty u(σ) = 31×10-24 cm2, corresponding to a relative level of 2 ‰. The measurements are most compatible with a relative temperature coefficient cT = σ-1 ∂ Tσ = 0.0031 K-1 at 294 K. The cross section and its uncertainty value were obtained using generalised linear regression with correlated uncertainties. It will serve as a reference for ozone absorption spectra required for the long-term remote sensing of atmospheric ozone in the Huggins bands. The comparison with commonly used absorption cross-section data sets for remote sensing reveals a possible bias of about 2 %. This could partly explain a 4 % discrepancy between UV and IR remote sensing data and indicates that further studies will be required to reach the accuracy goal of 1 % in atmospheric reference spectra.
Physical fitness percentile charts for children aged 6-10 from Portugal.
Roriz De Oliveira, M S; Seabra, A; Freitas, D; Eisenmann, J C; Maia, J
2014-12-01
The present study aims (1) to provide reference percentile charts for the following measures of Physical Fitness (PF): the sit-and-reach, handgrip, standing long jump, 50 yards' dash, 4x10m shuttle run and 1-mile run/walk tests in children aged 6 to 10 years, and (2) to compare the performance of the Portuguese children with their age- and sex peers. A total of 3804 Portuguese children (1985 boys and 1819 girls) aged 6-10 years old participated in this study. The sample was stratified from 20 public elementary schools and children were randomly selected in each school. Charts were separately built for each sex using the LMS method. Boys showed better results than girls in handgrip, standing long jump, 50 yards' dash, 4x10 m shuttle run and 1-mile run/walk, while girls are better performers than boys in sit-and-reach. Age- and gender- percentiles for a set of physical fitness tests for 6-10 year old (primary school) Portuguese children have been established. Boys showed greater overall PF than girls, except in the flexibility test, in which girls performed better. The reported normative values provide ample opportunities to accurately detect individual changes during childhood. These reference values are especially important in healthcare and educational settings, and can be added to the worldwide literature on physical fitness values in children.
Recommended energy and nutrients intakes in the European Union: 2008-2016
García Gabarra, Antoni; Castellà Soley, Marta; Calleja Fernández, Alicia
2017-03-30
The aim of this document is to refl ect the changes happened in the European Union legislation and the opinions of the European Food Safety Authority in relation to the nutritional labeling on food, the reference values for energy, macronutrients and micronutrients, and the tolerable upper safe levels. The European legislation in force uses the labeling reference values established by the Scientific Committee on Food in 2003. There would be advisable an update of them from the reference values for vitamins and minerals established by the European Food Safety Authority. Equally, there would be good to include reference labeling values for polyunsaturated fatty acids, dietary fiber and choline, and specific reference labeling values for children from 6 to 36 months. For vitamins and minerals there would be desirable the revision of tolerable upper safe levels and the establishment of maximum amounts allowed in fortified food and food supplements in the European Union; its absence might represent a risk in some population groups for an excessive and unsafe intake of certain minerals and vitamins.
Kawai, Y; Nagai, Y; Ogawa, E; Kondo, H
2017-04-01
To provide target values for the manufacturers' survey of the Japanese Society for Laboratory Hematology (JSLH), accurate standard data from healthy volunteers were needed for the five-part differential leukocyte count. To obtain such data, JSLH required an antibody panel that achieved high specificity (particularly for mononuclear cells) using simple gating procedures. We developed a flow cytometric method for determining the differential leukocyte count (JSLH-Diff) and validated it by comparison with the flow cytometric differential leukocyte count of the International Council for Standardization in Haematology (ICSH-Diff) and the manual differential count obtained by microscopy (Manual-Diff). First, the reference laboratory performed an imprecision study of JSLH-Diff and ICSH-Diff, as well as performing comparison among JSLH-Diff, Manual-Diff, and ICSH-Diff. Then two reference laboratories and seven participating laboratories performed imprecision and accuracy studies of JSLH-Diff, Manual-Diff, and ICSH-Diff. Simultaneously, six manufacturers' laboratories provided their own representative values by using automated hematology analyzers. The precision of both JSLH-Diff and ICSH-Diff methods was adequate. Comparison by the reference laboratory showed that all correlation coefficients, slopes and intercepts obtained by the JSLH-Diff, ICSH-Diff, and Manual-Diff methods conformed to the criteria. When the imprecision and accuracy of JSLH-Diff were assessed at seven laboratories, the CV% for lymphocytes, neutrophils, monocytes, eosinophils, and basophils was 0.5~0.9%, 0.3~0.7%, 1.7~2.6%, 3.0~7.9%, and 3.8~10.4%, respectively. More than 99% of CD45 positive leukocytes were identified as normal leukocytes by JSLH-Diff. When JSLH-Diff method were validated by comparison with Manual-Diff and ICSH-Diff, JSLH-Diff showed good performance as a reference method. © 2016 John Wiley & Sons Ltd.
Interleukin-6 and tumor necrosis factor-alpha values in elk neonates
Barber-Meyer, S. M.; Johnson, C.R.; Murtaugh, M.P.; Mech, L.D.; White, P.J.
2007-01-01
Serological indicators of general condition would be helpful for monitoring or assessing ungulate wildlife. Toward that end, we report the 1st reference values for 2 cytokines, interleukin-6 (IL-6) and tumor necrosis factor-alpha (TNF-??), in neonatal elk (Cervus elaphus). We obtained blood samples from 140 calves ??? 6 days old in Yellowstone National Park during summer 2003-2005. TL-6 values ranged from 0 to 1.21 pg/ml with a median of 0.03 pg/ml. TNF-?? values ranged from 0 to 225.43 pg/ml with a median of 1.85 pg/ml. IL-6 and TNF-?? concentrations were not significant predictors of elk calf survival through 21 days. Development of ungulate-based IL-6 and TNF-?? assays that provide greater sensitivity than cross-reacting human-based assays could be helpful in monitoring ungulate condition and health status comparisons among herds. Such information could provide indirect assessments of range quality or environmental influences among herds.
Ng, Chaan S.; Hobbs, Brian P.; Wei, Wei; Anderson, Ella F.; Herron, Delise H.; Yao, James C.; Chandler, Adam G.
2014-01-01
Objective To assess the effects of sampling interval (SI) of CT perfusion acquisitions on CT perfusion values in normal liver and liver metastases from neuroendocrine tumors. Methods CT perfusion in 16 patients with neuroendocrine liver metastases were analyzed by distributed parameter modeling to yield tissue blood flow, blood volume, mean transit time, permeability, and hepatic arterial fraction, for tumor and normal liver. CT perfusion values for the reference sampling interval of 0.5s (SI0.5) were compared with those of SI datasets of 1s, 2s, 3s and 4s, using mixed-effects model analyses. Results Increases in SI beyond 1s were associated with significant and increasing departures of CT perfusion parameters from reference values at SI0.5 (p≤0.0009). CT perfusion values deviated from reference with increasing uncertainty with increasing SIs. Findings for normal liver were concordant. Conclusion Increasing SIs beyond 1s yield significantly different CT perfusion parameter values compared to reference values at SI0.5. PMID:25626401
[Reference values of energy for the Venezuelan population].
Landaeta-Jiménez, Maritza; Aliaga, Carla; Sifontes, Yaritza; Vásquez, Maura; Ramírez, Guillermo; Falque Madrid, Luís; Herrera, Marianella; María Reyes, Ana; Emilia, Elzakem; Herrera, Ctor; Bernal, Jennifer
2013-12-01
The project of updating the Venezuelan energy reference values respond to the recommendations made by an FAO experts committee, several decades ago for the countries assuming this work. Because of the dramatic changes experienced globally regarding energy intake/expenditure and particularly variations on the Venezuelan nutritional scenario with the presence of "the double burden of malnutrition" it a review of Energy Reference Values (VRE) from a more integral approach is pertinent. This report follows the methodology proposed by FAO/WHO/UNU 2004 experts committee and energy reference values were established by group of age and gender, also average energy values for Venezuelan population were obtained. For calculation of these requirements, the energy expenditure was included by taking into account Basal Metabolic Rate and physical activity level for some specific groups. The score average values updated in 2012 of 2.200 kcal/dia reported to be lower than those of 2000 at all ages for masculine gender except for the 16-17 age group and for feminine gender just until ages 10-12 years and from there are slightly above the values obtained in 2000.
Patel, Samir
2015-03-01
Health care is in a state of transition, shifting from volume-based success to value-based success. Hospital executives and referring physicians often do not understand the total value a radiology group provides. A template for easy, cost-effective implementation in clinical practice for most radiology groups to demonstrate the value they provide to their clients (patients, physicians, health care executives) has not been well described. A value management program was developed to document all of the value-added activities performed by on-site radiologists, quantify them in terms of time spent on each activity (investment), and present the benefits to internal and external stakeholders (outcomes). The radiology value-added matrix is the platform from which value-added activities are categorized and synthesized into a template for defining investments and outcomes. The value management program was first implemented systemwide in 2013. Across all serviced locations, 9,931.75 hours were invested. An annual executive summary report template demonstrating outcomes is given to clients. The mean and median individual value-added hours per radiologist were 134.52 and 113.33, respectively. If this program were extrapolated to the entire field of radiology, approximately 30,000 radiologists, this would have resulted in 10,641,161 uncompensated value-added hours documented in 2013, with an estimated economic value of $2.21 billion. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea
2016-03-26
Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients' care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine.
Zhang, Gao-Ming; Guo, Xu-Xiao; Ma, Xiao-Bo; Zhang, Guo-Ming
2016-01-01
Background The aim of this study was to calculate 95% reference intervals and double-sided limits of serum alpha-fetoprotein (AFP) and carcinoembryonic antigen (CEA) according to the CLSI EP28-A3 guideline. Material/Methods Serum AFP and CEA values were measured in samples from 26 000 healthy subjects in the Shuyang area receiving general health checkups. The 95% reference intervals and upper limits were calculated by using MedCalc. Results We provided continuous reference intervals from 20 years old to 90 years old for AFP and CEA. The reference intervals were: AFP, 1.31–7.89 ng/ml (males) and 1.01–7.10 ng/ml (females); CEA, 0.51–4.86 ng/ml (males) and 0.35–3.45ng/ml (females). AFP and CEA were significantly positively correlated with age in both males (r=0.196 and r=0.198) and females (r=0.121 and r=0.197). Conclusions Different races or populations and different detection systems may result in different reference intervals for AFP and CEA. Continuous reference intervals of age changes are more accurate than age groups. PMID:27941709
Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea
2016-01-01
Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients’ care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine. PMID:27019800
Roche, Nicolas; Dalmay, François; Perez, Thierry; Kuntz, Claude; Vergnenègre, Alain; Neukirch, Françoise; Giordanella, Jean-Pierre; Huchon, Gérard
2008-11-01
Little is known on the long-term validity of reference equations used in the calculation of FEV(1) and FEV(1)/FVC predicted values. This survey assessed the prevalence of chronic airflow obstruction in a population-based sample and how it is influenced by: (i) the definition of airflow obstruction; and (ii) equations used to calculate predicted values. Subjects aged 45 or more were recruited in health prevention centers, performed spirometry and fulfilled a standardized ECRHS-derived questionnaire. Previously diagnosed cases and risk factors were identified. Prevalence of airflow obstruction was calculated using: (i) ATS-GOLD definition (FEV(1)/FVC<0.70); and (ii) ERS definition (FEV(1)/FVC
Selk Ghaffari, Masoud; Sabzevari, Amin; Ghamsari, SeyedMehdi; Shad, Hussein
2017-11-25
This study was conducted to establish normal reference range for the Schirmer tear test (STT) and intraocular pressure (IOP) in clinically normal donkeys for use in clinical practice. Sixteen adult Ethiopian domestic donkeys were used in this study. Complete ophthalmic examinations were performed without chemical restraint. STT values were evaluated in both eyes of all donkeys using a commercial STT strip. IOP was measured in both eyes with a Tono-Pen Vet (Reichert. USA) without using regional nerve blocks. STT values for all eyes (n=32) were 22.1±6.9 mm/minute with a range of 13-35 mm/minute. Comparison of mean STT values between right (n=16) and left eyes (n=16) showed no differences (P=0.6). Mean ±sd IOP values by applanation tonometry were 17.8±3.7 mmHg (range 13.5-24.5 mmHg). Comparison of mean IOP values between right (n=16) and left eyes (n=16) showed no differences (P=0.7). This initial survey provides means and ranges for IOP and STT values in donkeys. These data will assist veterinary ophthalmologists in more accurate diagnosis and management of ophthalmic diseases in donkeys, including keratoconjunctivitis sicca and glaucoma. © British Veterinary Association (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Gabrial, Shreef G. N.; Shakib, Marie-Christine R.; Gabrial, Gamal N.
2016-01-01
BACKGROUND: Many studies have indicated that the incidence of serious diabetic complications may be reduced through strict glycemic control. A low glycemic index diet is one tool to improve insulin resistance and improve glycemic control in type 2 diabetes mellitus (T2DM). AIM: The objective was to study the effect of pseudocereals-based breakfasts (quinoa and buckwheat) on glucose variations at first meal (breakfast) and second meal (standardised lunch) in healthy and diabetic subjects. SUBJECTS AND METHODS: Twelve healthy subjects and 12 patients with Type 2 DM (not- insulin dependent) were recruited in the study. Subjects were provided with quinoa and buckwheat breakfast meals. A standardised lunch was provided 4 h after breakfast. Postprandial blood glucose response after breakfast and the second meal effect was measured in healthy and diabetic subjects. Incremental area under the curve (IAUC) values for glucose was measured in response to the breakfast and lunch. The glycemic index of the 2 pseudocereals-based test breakfasts was determined. A white wheat bread (WWB) was served as a reference breakfast meal. RESULTS: In post-breakfast analyses, healthy subjects showed that buckwheat meal had significantly lower IAUC values for blood glucose compared to WWB reference meal (P < 0.001) while quinoa meal showed no significance. In diabetic subjects, buckwheat and quinoa meals had significantly lower IAUC values for blood glucose compared to WWB reference meal (P < 0.001 and P < 0.05 respectively). Blood glucose concentrations started to decline gradually for the quinoa and buckwheat but not for WWB in all healthy and diabetic subjects and returned to near-fasting baseline levels by 210 min. Post-lunch analyses indicated higher IAUC for the two breakfast types in healthy and diabetic subjects. In addition, the quinoa and buckwheat breakfast meals were followed by a significantly flatter blood glucose response to the second meal for the period between 270 and 330 min. At the end of the second meal period, values were below or near-fasting baseline levels in the breakfast period. The blood glucose concentration after consuming quinoa meal showed a high peak at 30 min similar to that of WWB reference meal. This peak resulted in a high glycemic index (GI) for quinoa (89.4). The GI of buckwheat recorded a low value (26.8). CONCLUSION: The two studied pseudocereals; quinoa and buckwheat have high potential to improve glucose tolerance at the first and second meal (lunch) and are recommended to be introduced in our daily diet for healthy and diabetic subjects. PMID:28028392
Multicomponent blood lipid analysis by means of near infrared spectroscopy, in geese.
Bazar, George; Eles, Viktoria; Kovacs, Zoltan; Romvari, Robert; Szabo, Andras
2016-08-01
This study provides accurate near infrared (NIR) spectroscopic models on some laboratory determined clinicochemical parameters (i.e. total lipid (5.57±1.95 g/l), triglyceride (2.59±1.36 mmol/l), total cholesterol (3.81±0.68 mmol/l), high density lipoprotein (HDL) cholesterol (2.45±0.58 mmol/l)) of blood serum samples of fattened geese. To increase the performance of multivariate chemometrics, samples significantly deviating from the regression models implying laboratory error were excluded from the final calibration datasets. Reference data of excluded samples having outlier spectra in principal component analysis were not marked as false. Samples deviating from the regression models but having non outlier spectra in PCA were identified as having false reference constituent values. Based on the NIR selection methods, 5% of the reference measurement data were rated as doubtful. The achieved models reached R(2) of 0.864, 0.966, 0.850, 0.793, and RMSE of 0.639 g/l, 0.232 mmol/l, 0.210 mmol/l, 0.241 mmol/l for total lipid, triglyceride, total cholesterol and HDL cholesterol, respectively, during independent validation. Classical analytical techniques focus on single constituents and often require chemicals, time-consuming measurements, and experienced technicians. NIR technique provides a quick, cost effective, non-hazardous alternative method for analysis of several constituents based on one single spectrum of each sample, and it also offers the possibility for looking at the laboratory reference data critically. Evaluation of reference data to identify and exclude falsely analyzed samples can provide warning feedback to the reference laboratory, especially in the case of analyses where laboratory methods are not perfectly suited to the subjected material and there is an increased chance of laboratory error. Copyright © 2016 Elsevier B.V. All rights reserved.
Mekonnen, Zewdie; Amuamuta, Asmare; Mulu, Wondemagegn; Yimer, Mulat; Zenebe, Yohannes; Adem, Yesuf; Abera, Bayeh; Gebeyehu, Wondemu; Gebregziabher, Yakob
2017-01-01
Reference interval is crucial for disease screening, diagnosis, monitoring, progression and treatment efficacy. Due to lack of locally derived reference values for the parameters, clinicians use reference intervals derived from western population. But, studies conducted in different African countries have indicated differences between locally and western derived reference values. Different studies also indicated considerable variation in clinical chemistry reference intervals by several variables such as age, sex, geographical location, environment, lifestyle and genetic variation. This study aimed to determine the reference intervals of common clinical chemistry parameters of the community of Gojjam Zones, Northwest Ethiopia. Population based cross-sectional study was conducted from November 2015 to December 2016 in healthy adult populations of Gojjam zone. Data such as, medical history, physical examination and socio-demographic data were collected. In addition, laboratory investigations were undertaken to screen the population. Clinical chemistry parameters were measured using Mindray BS 200 clinical chemistry autoanalyzer as per the manufacturer's instructions. Descriptive statistics was used to calculate mean, median and 95th percentiles. Independent sample T-test and one way ANOVA were used to see association between variables. After careful screening of a total of 799 apparently healthy adults who were consented for this study, complete data from 446 (224 females and 222 males) were included for the analysis. The mean age of both the study participants was 28.8 years. Males had high (P<0.05) mean and 2.5th-97.5th percentile ranges of ALT, AST, ALP, creatinine and direct bilirubin. The reference intervals of amylase, LDH, total protein and total bilirubin were not significantly different between the two sex groups (P>0.05). Mean, median, 95% percentile values of AST, ALP, amylase, LDH, creatinine, total protein, total bilirubin, and direct bilirubin across all age groups of participants were similar (P>0.05). But, there was a significant difference in the value of ALT (P<0.05). The reference intervals of ALT, total protein and creatinine were significantly (P<0.05) high in people having monthly income >1500 ETB compared to those with low monthly income. Significant (P<0.05) higher values of the ALT, ALP and total protein were observed in people living in high land compared to low land residences. The study showed that some of the common clinical chemistry parameters reference intervals of healthy adults in Gojjam zones were higher than the reference intervals generated from developed countries. Therefore, strict adherence to the reference values generated in developed countries could lead to inappropriate diagnosis and treatment of patients. There was also variation of reference interval values based on climate, gender, age, monthly income and geographical locations. Therefore, further study is required to establish reference intervals for Ethiopian population.
Watanabe, Hiroshi; Nomura, Yoshikazu; Kuribayashi, Ami; Kurabayashi, Tohru
2018-02-01
We aimed to employ the Radia diagnostic software with the safety and efficacy of a new emerging dental X-ray modality (SEDENTEXCT) image quality (IQ) phantom in CT, and to evaluate its validity. The SEDENTEXCT IQ phantom and Radia diagnostic software were employed. The phantom was scanned using one medical full-body CT and two dentomaxillofacial cone beam CTs. The obtained images were imported to the Radia software, and the spatial resolution outputs were evaluated. The oversampling method was employed using our original wire phantom as a reference. The resultant modulation transfer function (MTF) curves were compared. The null hypothesis was that MTF curves generated using both methods would be in agreement. One-way analysis of variance tests were applied to the f50 and f10 values from the MTF curves. The f10 values were subjectively confirmed by observing the line pair modules. The Radia software reported the MTF curves on the xy-plane of the CT scans, but could not return f50 and f10 values on the z-axis. The null hypothesis concerning the reported MTF curves on the xy-plane was rejected. There were significant differences between the results of the Radia software and our reference method, except for f10 values in CS9300. These findings were consistent with our line pair observations. We evaluated the validity of the Radia software with the SEDENTEXCT IQ phantom. The data provided were semi-automatic, albeit with problems and statistically different from our reference. We hope the manufacturer will overcome these limitations.
Buonaccorsi, John P; Dalen, Ingvild; Laake, Petter; Hjartåker, Anette; Engeset, Dagrun; Thoresen, Magne
2015-04-15
Measurement error occurs when we observe error-prone surrogates, rather than true values. It is common in observational studies and especially so in epidemiology, in nutritional epidemiology in particular. Correcting for measurement error has become common, and regression calibration is the most popular way to account for measurement error in continuous covariates. We consider its use in the context where there are validation data, which are used to calibrate the true values given the observed covariates. We allow for the case that the true value itself may not be observed in the validation data, but instead, a so-called reference measure is observed. The regression calibration method relies on certain assumptions.This paper examines possible biases in regression calibration estimators when some of these assumptions are violated. More specifically, we allow for the fact that (i) the reference measure may not necessarily be an 'alloyed gold standard' (i.e., unbiased) for the true value; (ii) there may be correlated random subject effects contributing to the surrogate and reference measures in the validation data; and (iii) the calibration model itself may not be the same in the validation study as in the main study; that is, it is not transportable. We expand on previous work to provide a general result, which characterizes potential bias in the regression calibration estimators as a result of any combination of the violations aforementioned. We then illustrate some of the general results with data from the Norwegian Women and Cancer Study. Copyright © 2015 John Wiley & Sons, Ltd.
Lee, Joonnyong; Sohn, JangJay; Park, Jonghyun; Yang, SeungMan; Lee, Saram; Kim, Hee Chan
2018-06-18
Non-invasive continuous blood pressure monitors are of great interest to the medical community due to their value in hypertension management. Recently, studies have shown the potential of pulse pressure as a therapeutic target for hypertension, but not enough attention has been given to non-invasive continuous monitoring of pulse pressure. Although accurate pulse pressure estimation can be of direct value to hypertension management and indirectly to the estimation of systolic blood pressure, as it is the sum of pulse pressure and diastolic blood pressure, only a few inadequate methods of pulse pressure estimation have been proposed. We present a novel, non-invasive blood pressure and pulse pressure estimation method based on pulse transit time and pre-ejection period. Pre-ejection period and pulse transit time were measured non-invasively using electrocardiogram, seismocardiogram, and photoplethysmogram measured from the torso. The proposed method used the 2-element Windkessel model to model pulse pressure with the ratio of stroke volume, approximated by pre-ejection period, and arterial compliance, estimated by pulse transit time. Diastolic blood pressure was estimated using pulse transit time, and systolic blood pressure was estimated as the sum of the two estimates. The estimation method was verified in 11 subjects in two separate conditions with induced cardiovascular response and the results were compared against a reference measurement and values obtained from a previously proposed method. The proposed method yielded high agreement with the reference (pulse pressure correlation with reference R ≥ 0.927, diastolic blood pressure correlation with reference R ≥ 0.854, systolic blood pressure correlation with reference R ≥ 0.914) and high estimation accuracy in pulse pressure (mean root-mean-squared error ≤ 3.46 mmHg) and blood pressure (mean root-mean-squared error ≤ 6.31 mmHg for diastolic blood pressure and ≤ 8.41 mmHg for systolic blood pressure) over a wide range of hemodynamic changes. The proposed pulse pressure estimation method provides accurate estimates in situations with and without significant changes in stroke volume. The proposed method improves upon the currently available systolic blood pressure estimation methods by providing accurate pulse pressure estimates.
Estimation of reference intervals from small samples: an example using canine plasma creatinine.
Geffré, A; Braun, J P; Trumel, C; Concordet, D
2009-12-01
According to international recommendations, reference intervals should be determined from at least 120 reference individuals, which often are impossible to achieve in veterinary clinical pathology, especially for wild animals. When only a small number of reference subjects is available, the possible bias cannot be known and the normality of the distribution cannot be evaluated. A comparison of reference intervals estimated by different methods could be helpful. The purpose of this study was to compare reference limits determined from a large set of canine plasma creatinine reference values, and large subsets of this data, with estimates obtained from small samples selected randomly. Twenty sets each of 120 and 27 samples were randomly selected from a set of 1439 plasma creatinine results obtained from healthy dogs in another study. Reference intervals for the whole sample and for the large samples were determined by a nonparametric method. The estimated reference limits for the small samples were minimum and maximum, mean +/- 2 SD of native and Box-Cox-transformed values, 2.5th and 97.5th percentiles by a robust method on native and Box-Cox-transformed values, and estimates from diagrams of cumulative distribution functions. The whole sample had a heavily skewed distribution, which approached Gaussian after Box-Cox transformation. The reference limits estimated from small samples were highly variable. The closest estimates to the 1439-result reference interval for 27-result subsamples were obtained by both parametric and robust methods after Box-Cox transformation but were grossly erroneous in some cases. For small samples, it is recommended that all values be reported graphically in a dot plot or histogram and that estimates of the reference limits be compared using different methods.
Experimental validation of beam quality correction factors for proton beams
NASA Astrophysics Data System (ADS)
Gomà, Carles; Hofstetter-Boillat, Bénédicte; Safai, Sairos; Vörös, Sándor
2015-04-01
This paper presents a method to experimentally validate the beam quality correction factors (kQ) tabulated in IAEA TRS-398 for proton beams and to determine the kQ of non-tabulated ionization chambers (based on the already tabulated values). The method is based exclusively on ionometry and it consists in comparing the reading of two ionization chambers under the same reference conditions in a proton beam quality Q and a reference beam quality 60Co. This allows one to experimentally determine the ratio between the kQ of the two ionization chambers. In this work, 7 different ionization chamber models were irradiated under the IAEA TRS-398 reference conditions for 60Co beams and proton beams. For the latter, the reference conditions for both modulated beams (spread-out Bragg peak field) and monoenergetic beams (pseudo-monoenergetic field) were studied. For monoenergetic beams, it was found that the experimental kQ values obtained for plane-parallel chambers are consistent with the values tabulated in IAEA TRS-398; whereas the kQ values obtained for cylindrical chambers are not consistent—being higher than the tabulated values. These results support the suggestion (of previous publications) that the IAEA TRS-398 reference conditions for monoenergetic proton beams should be revised so that the effective point of measurement of cylindrical ionization chambers is taken into account when positioning the reference point of the chamber at the reference depth. For modulated proton beams, the tabulated kQ values of all the ionization chambers studied in this work were found to be consistent with each other—except for the IBA FC65-G, whose experimental kQ value was found to be 0.6% lower than the tabulated one. The kQ of the PTW Advanced Markus chamber, which is not tabulated in IAEA TRS-398, was found to be 0.997 ± 0.042 (k = 2), based on the tabulated value of the PTW Markus chamber.
Piller, Nicolas; Decosterd, Isabelle; Suter, Marc R
2013-07-10
The reverse transcription quantitative real-time polymerase chain reaction (RT-qPCR) is a widely used, highly sensitive laboratory technique to rapidly and easily detect, identify and quantify gene expression. Reliable RT-qPCR data necessitates accurate normalization with validated control genes (reference genes) whose expression is constant in all studied conditions. This stability has to be demonstrated.We performed a literature search for studies using quantitative or semi-quantitative PCR in the rat spared nerve injury (SNI) model of neuropathic pain to verify whether any reference genes had previously been validated. We then analyzed the stability over time of 7 commonly used reference genes in the nervous system - specifically in the spinal cord dorsal horn and the dorsal root ganglion (DRG). These were: Actin beta (Actb), Glyceraldehyde-3-phosphate dehydrogenase (GAPDH), ribosomal proteins 18S (18S), L13a (RPL13a) and L29 (RPL29), hypoxanthine phosphoribosyltransferase 1 (HPRT1) and hydroxymethylbilane synthase (HMBS). We compared the candidate genes and established a stability ranking using the geNorm algorithm. Finally, we assessed the number of reference genes necessary for accurate normalization in this neuropathic pain model. We found GAPDH, HMBS, Actb, HPRT1 and 18S cited as reference genes in literature on studies using the SNI model. Only HPRT1 and 18S had been once previously demonstrated as stable in RT-qPCR arrays. All the genes tested in this study, using the geNorm algorithm, presented gene stability values (M-value) acceptable enough for them to qualify as potential reference genes in both DRG and spinal cord. Using the coefficient of variation, 18S failed the 50% cut-off with a value of 61% in the DRG. The two most stable genes in the dorsal horn were RPL29 and RPL13a; in the DRG they were HPRT1 and Actb. Using a 0.15 cut-off for pairwise variations we found that any pair of stable reference gene was sufficient for the normalization process. In the rat SNI model, we validated and ranked Actb, RPL29, RPL13a, HMBS, GAPDH, HPRT1 and 18S as good reference genes in the spinal cord. In the DRG, 18S did not fulfill stability criteria. The combination of any two stable reference genes was sufficient to provide an accurate normalization.
[Muscle strength of the cervical and lumbar spine in triathletes].
Miltner, O; Siebert, C H; Müller-Rath, R; Kieffer, O
2010-12-01
The goal of this study was to analyse the muscle strength of the cervical and lumbar spine in ironman triathletes. The values were compared to the results obtained from a reference group. The test of the triathletes was carried out in an attempt to define a specific strength profile for these athletes. In this study, 20 long-distance triathletes (∅ 37.3 ± 7.6 years of age, ∅ 1.80 ± 0.1 m, ∅ 73.7 ± 6.0 kg) were evaluated with regard to their individual and sport-specific strengths of the cervical spine in 2 planes and of the trunk strengths in all 3 planes of motion. The trunk strength profile of the triathletes revealed good average results in the trunk extensors and the lateral flexors of the left trunk. The reference group is the data base of the company Proxomed®, Alzenau. It is based on results of 1045 untrained, symptom-free subjects of different ages. Lumbar extension: The extension of the force values shows no significant difference from the reference group. Lumbar flexion: The flexion tests show highly significantly lower force values (5.025 ± 0.81 N/kg vs. 6.67 ± 0.6 N/kg) than the reference group. Flexion/extension: In the sagittal plane values for the triathletes demonstrate an imbalance in muscle strength ratios. The abdominal muscles turn in relation to the back extensor muscles too weakly to be very significant. Lumbar rotation: The force values of the athletes in both directions (right: 6.185 ± 1.46 N/kg, left: 7.1 ± 1.57 N/kg vs. 10.05 ± 0.34 N/kg) are highly significantly (p ≤ 0.001) lower than the reference values. Ratio of rotation left/right: The ratio of left/right rotation in the reference group is set at 1 and thus shows an equally strong force level between the two sides. Lumbar lateral flexion: The triathletes do not show any significant differences between the force values. Compared to the reference group there is no significant difference to the left side flexion. In the lateral bending the athletes have significantly better values than the reference group. Ratio of lateral left/right: In the reference group the ratio is set at 1. For triathletes, it shows an average value of 0.93. This difference is not significant. Cervical extension: The extension of the force values (1.96 ± 0.59 N/kg vs. 3.03 ± 0.24 N/kg) shows a highly significant difference from the reference group. Cervical flexion: In flexion (1.3 ± 0.42 N/kg vs. 2.17 ± 0.22 N/kg) triathletes have highly significantly lower strength values than the reference group. Flexion/extension: The triathletes did not differ significantly from the reference values (0.69 ± 0.23 and 0.72 ± 0.08). Lateral cervical spine: In comparison to the reference group (left: 1.67 ± 0.48 N/kg, right: 1.55 ± 0.46 N/kg vs. 2.36 ± 0.15 N/kg) in which there is left/right lateral flexion, there is a highly significant difference. Right lateral flexion is weaker than the left. Ratio of lateral left/right: The triathletes have a significant imbalance in the lateral flexion of the cervical spine compared to the reference group (1.07 ± 0.15 to 1). In conclusion, in the triathlon there is a specific stress that is obviously not an adequate stimulus for the muscles of the cervical spine in order to achieve a balanced musculature and the athletes should be advised to practice a preventive approach with regard to these areas. © Georg Thieme Verlag KG Stuttgart · New York.
Stokes, Ashley M.; Semmineh, Natenael; Quarles, C. Chad
2015-01-01
Purpose A combined biophysical- and pharmacokinetic-based method is proposed to separate, quantify, and correct for both T1 and T2* leakage effects using dual-echo DSC acquisitions to provide more accurate hemodynamic measures, as validated by a reference intravascular contrast agent (CA). Methods Dual-echo DSC-MRI data were acquired in two rodent glioma models. The T1 leakage effects were removed and also quantified in order to subsequently correct for the remaining T2* leakage effects. Pharmacokinetic, biophysical, and combined biophysical and pharmacokinetic models were used to obtain corrected cerebral blood volume (CBV) and cerebral blood flow (CBF), and these were compared with CBV and CBF from an intravascular CA. Results T1-corrected CBV was significantly overestimated compared to MION CBV, while T1+T2*-correction yielded CBV values closer to the reference values. The pharmacokinetic and simplified biophysical methods showed similar results and underestimated CBV in tumors exhibiting strong T2* leakage effects. The combined method was effective for correcting T1 and T2* leakage effects across tumor types. Conclusions Correcting for both T1 and T2* leakage effects yielded more accurate measures of CBV. The combined correction method yields more reliable CBV measures than either correction method alone, but for certain brain tumor types (e.g., gliomas) the simplified biophysical method may provide a robust and computationally efficient alternative. PMID:26362714
Values for Human-to-Human Reference.
ERIC Educational Resources Information Center
Gorman, Michael
2001-01-01
Defines "values" and lists the eight values (stewardship, service, intellectual freedom, rationalism, literacy and learning, equity of access, privacy, democracy) derived by the author in an earlier work. Gives a brief history of the evolution of human-to-human reference service and discusses its future. Relates each of the author's eight values…
Calhoun, Peter; Lum, John; Beck, Roy W; Kollman, Craig
2013-09-01
Knowledge of the accuracy of continuous glucose monitoring (CGM) devices is important for its use as a management tool for individuals with diabetes and for its use to assess outcomes in clinical studies. Using data from several inpatient studies, we compared the accuracy of two sensors, the Medtronic Enlite™ using MiniMed Paradigm(®) Veo™ calibration and the Sof-Sensor(®) glucose sensor using Guardian(®) REAL-Time CGM calibration (all from Medtronic Diabetes, Northridge, CA). Nocturnal data were analyzed from eight inpatient studies in which both CGM and reference glucose measurements were available. The analyses included 1,666 CGM-reference paired glucose values for the Enlite in 54 participants over 69 nights and 3,627 paired values for the Sof-Sensor in 66 participants over 91 nights. The Enlite sensor tended to report glucose levels lower than the reference over the entire range of glucose values, whereas the Sof-Sensor values tended to be higher than reference values in the hypoglycemic range and lower than reference values in the hyperglycemic range. The overall median sensor-reference difference was -15 mg/dL for the Enlite and -1 mg/dL for the Sof-Sensor (P<0.001). The median relative absolute difference was 15% for the Enlite versus 12% for the Sof-Sensor (P=0.06); 66% of Enlite values and 73% of Sof-Sensor values met International Organization for Standardization criteria. We found that the Enlite tended to be biased low over the entire glucose range, whereas the Sof-Sensor showed the more typical sensor pattern of being biased high in the hypoglycemic range and biased low in the hyperglycemic range.
Animal experimentation--a personal view.
Gershoff, Stanley N
2009-02-01
Disagreement about the use of animals in biomedical research has resulted in absurd positions by both sides. Increasingly, some zealots against animal experimentation have resorted to violence or other illegal acts to support their points of view. The value of animal research in providing better health for man and animals is incontrovertible. This is illustrated by references to animal research in the field of nutrition.
2011-03-24
4.13. The green circle denotes a ‘ self identification’ of a reference point. This allows a user to place the cursor over what he/she thought was a...deflection’. Figure 4.27 extrap- olates the point residual values (in %) associated with the points that are resposible for providing this thesis
ERIC Educational Resources Information Center
Mulroy, Kevin J.
The hypothesis was advanced that if the proverbs of a country could provide clues to its inhabitants' character which could be validated by reference to literature and commentaries of various types, an excellent guide would be available for educators. The information could be of value to teachers in that it would increase sensitivity to students,…
Navigating confluences: revisiting the meaning of "wilderness experience"
Karen M. Fox
2000-01-01
Concepts of wilderness and âwilderness experienceâ merge into a grand or metanarrative that describes how âwilderness experienceâ is and provides a normalized reference point for values, beliefs, actions, and choices. This paper engages and juxtaposes critiques by scholars and authors representing nondominant perspectives with the North American, wilderness...
Leen, Wilhelmina G.; Willemsen, Michèl A.; Wevers, Ron A.; Verbeek, Marcel M.
2012-01-01
Cerebrospinal fluid (CSF) analysis is an important tool in the diagnostic work-up of many neurological disorders, but reference ranges for CSF glucose, CSF/plasma glucose ratio and CSF lactate based on studies with large numbers of CSF samples are not available. Our aim was to define age-specific reference values. In 1993 The Nijmegen Observational CSF Study was started. Results of all CSF samples that were analyzed between 1993 and 2008 at our laboratory were systematically collected and stored in our computerized database. After exclusion of CSF samples with an unknown or elevated erythrocyte count, an elevated leucocyte count, elevated concentrations of bilirubin, free hemoglobin, or total protein 9,036 CSF samples were further studied for CSF glucose (n = 8,871), CSF/plasma glucose ratio (n = 4,516) and CSF lactate values (n = 7,614). CSF glucose, CSF/plasma glucose ratio and CSF lactate were age-, but not sex dependent. Age-specific reference ranges were defined as 5–95th percentile ranges. CSF glucose 5th percentile values ranged from 1.8 to 2.9 mmol/L and 95th percentile values from 3.8 to 5.6 mmol/L. CSF/plasma glucose ratio 5th percentile values ranged from 0.41 to 0.53 and 95th percentile values from 0.82 to 1.19. CSF lactate 5th percentile values ranged from 0.88 to 1.41 mmol/L and 95th percentile values from 2.00 to 2.71 mmol/L. Reference ranges for all three parameters were widest in neonates and narrowest in toddlers, with lower and upper limits increasing with age. These reference values allow a reliable interpretation of CSF results in everyday clinical practice. Furthermore, hypoglycemia was associated with an increased CSF/plasma glucose ratio, whereas hyperglycemia did not affect the CSF/plasma glucose ratio. PMID:22880096
Jeffery, Nick D; Bate, Simon T; Safayi, Sina; Howard, Matthew A; Moon, Lawrence; Jeffery, Unity
2018-03-01
In animal experiments, neuroscientists typically assess the effectiveness of interventions by comparing the average response of groups of treated and untreated animals. While providing useful insights, focusing only on group effects risks overemphasis of small, statistically significant but physiologically unimportant, differences. Such differences can be created by analytical variability or physiological within-individual variation, especially if the number of animals in each group is small enough that one or two outlier values can have considerable impact on the summary measures for the group. Physicians face a similar dilemma when comparing two results from the same patient. To determine whether the change between two values reflects disease progression or known analytical and physiological variation, the magnitude of the difference between two results is compared to the reference change value. These values are generated by quantifying analytical and within-individual variation, and differences between two results from the same patient are considered clinically meaningful only if they exceed the combined effect of these two sources of 'noise'. In this article, we describe how the reference change interval can be applied within neuroscience. This form of analysis provides a measure of outcome at an individual level that complements traditional group-level comparisons, and therefore, introduction of this technique into neuroscience can enrich interpretation of experimental data. It can also safeguard against some of the possible misinterpretations that may occur during analysis of the small experimental groups that are common in neuroscience and, by illuminating analytical error, may aid in design of more efficient experimental methods. © 2018 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.
A National Trial on Differences in Cerebral Perfusion Pressure Values by Measurement Location.
McNett, Molly M; Bader, Mary Kay; Livesay, Sarah; Yeager, Susan; Moran, Cristina; Barnes, Arianna; Harrison, Kimberly R; Olson, DaiWai M
2018-04-01
Cerebral perfusion pressure (CPP) is a key parameter in management of brain injury with suspected impaired cerebral autoregulation. CPP is calculated by subtracting intracranial pressure (ICP) from mean arterial pressure (MAP). Despite consensus on importance of CPP monitoring, substantial variations exist on anatomical reference points used to measure arterial MAP when calculating CPP. This study aimed to identify differences in CPP values based on measurement location when using phlebostatic axis (PA) or tragus (Tg) as anatomical reference points. The secondary study aim was to determine impact of differences on patient outcomes at discharge. This was a prospective, repeated measures, multi-site national trial. Adult ICU patients with neurological injury necessitating ICP and CPP monitoring were consecutively enrolled from seven sites. Daily MAP/ICP/CPP values were gathered with the arterial transducer at the PA, followed by the Tg as anatomical reference points. A total of 136 subjects were enrolled, resulting in 324 paired observations. There were significant differences for CPP when comparing values obtained at PA and Tg reference points (p < 0.000). Differences remained significant in repeated measures model when controlling for clinical factors (mean CPP-PA = 80.77, mean CPP-Tg = 70.61, p < 0.000). When categorizing CPP as binary endpoint, 18.8% of values were identified as adequate with PA values, yet inadequate with CPP values measured at the Tg. Findings identify numerical differences for CPP based on anatomical reference location and highlight importance of a standard reference point for both clinical practice and future trials to limit practice variations and heterogeneity of findings.
Research on energy efficiency design index for sea-going LNG carriers
NASA Astrophysics Data System (ADS)
Lin, Yan; Yu, Yanyun; Guan, Guan
2014-12-01
This paper describes the characteristics of liquefied natural gas (LNG) carriers briefly. The LNG carrier includes power plant selection, vapor treatment, liquid cargo tank type, etc. Two parameters—fuel substitution rate and recovery of boil of gas (BOG) volume to energy efficiency design index (EEDI) formula are added, and EEDI formula of LNG carriers is established based on ship EEDI formula. Then, based on steam turbine propulsion device of LNG carriers, mathematical models of LNG carriers' reference line value are established in this paper. By verification, the EEDI formula of LNG carriers described in this paper can provide a reference for LNG carrier EEDI calculation and green shipbuilding.
Hypothesis-driven classification of materials using nuclear magnetic resonance relaxometry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Espy, Michelle A.; Matlashov, Andrei N.; Schultz, Larry J.
Technologies related to identification of a substance in an optimized manner are provided. A reference group of known materials is identified. Each known material has known values for several classification parameters. The classification parameters comprise at least one of T.sub.1, T.sub.2, T.sub.1.rho., a relative nuclear susceptibility (RNS) of the substance, and an x-ray linear attenuation coefficient (LAC) of the substance. A measurement sequence is optimized based on at least one of a measurement cost of each of the classification parameters and an initial probability of each of the known materials in the reference group.
Acceptable Tolerances for Matching Icing Similarity Parameters in Scaling Applications
NASA Technical Reports Server (NTRS)
Anderson, David N.
2003-01-01
This paper reviews past work and presents new data to evaluate how changes in similarity parameters affect ice shapes and how closely scale values of the parameters should match reference values. Experimental ice shapes presented are from tests by various researchers in the NASA Glenn Icing Research Tunnel. The parameters reviewed are the modified inertia parameter (which determines the stagnation collection efficiency), accumulation parameter, freezing fraction, Reynolds number, and Weber number. It was demonstrated that a good match of scale and reference ice shapes could sometimes be achieved even when values of the modified inertia parameter did not match precisely. Consequently, there can be some flexibility in setting scale droplet size, which is the test condition determined from the modified inertia parameter. A recommended guideline is that the modified inertia parameter be chosen so that the scale stagnation collection efficiency is within 10 percent of the reference value. The scale accumulation parameter and freezing fraction should also be within 10 percent of their reference values. The Weber number based on droplet size and water properties appears to be a more important scaling parameter than one based on model size and air properties. Scale values of both the Reynolds and Weber numbers need to be in the range of 60 to 160 percent of the corresponding reference values. The effects of variations in other similarity parameters have yet to be established.
Brock, A Paige; Grunkemeyer, Vanessa L; Fry, Michael M; Hall, James S; Bartges, Joseph W
2013-12-01
To evaluate the relationship between osmolality and specific gravity of urine samples from clinically normal adult parrots and to determine a formula to convert urine specific gravity (USG) measured on a reference scale to a more accurate USG value for an avian species, urine samples were collected opportunistically from a colony of Hispaniolan Amazon parrots (Amazona ventralis). Samples were analyzed by using a veterinary refractometer, and specific gravity was measured on both canine and feline scales. Osmolality was measured by vapor pressure osmometry. Specific gravity and osmolality measurements were highly correlated (r = 0.96). The linear relationship between refractivity measurements on a reference scale and osmolality was determined. An equation was calculated to allow specific gravity results from a medical refractometer to be converted to specific gravity values of Hispaniolan Amazon parrots: USGHAp = 0.201 +0.798(USGref). Use of the reference-canine scale to approximate the osmolality of parrot urine leads to an overestimation of the true osmolality of the sample. In addition, this error increases as the concentration of urine increases. Compared with the human-canine scale, the feline scale provides a closer approximation to urine osmolality of Hispaniolan Amazon parrots but still results in overestimation of osmolality.
Imboden, Mary T; Swartz, Ann M; Finch, Holmes W; Harber, Matthew P; Kaminsky, Leonard A
2017-01-01
To develop reference values by age and sex for LM measures using GE-Healthcare DXA systems. A de-identified sample was obtained from Ball State University's Clinical Exercise Physiology Laboratory and University of Wisconsin-Milwaukee's Physical Activity & Health Research Laboratory. DXA scans of 2,076 women and 1,251 men were completed using a GE Lunar Prodigy or iDXA. Percentiles (%ile) were calculated for all variables of interest (LM, LMI, %LM, and ALMI) and a factorial ANOVA was used to assess differences for each variable between 10-year age groups and sex, as well as the interaction between age and sex. Men had higher mean total LM, %LM, LMI, and ALMI than women (p<0.01), across all age groups. All LM variables decreased significantly over the 5 decades in men, however in women only total LM, %LM, and ALMI decreased from the youngest to oldest age groups (p<0.01). These reference values provide for a more accurate interpretation of GE-Healthcare DXA-derived LM measurements offering clinicians and researchers with an initial resource to aid in the early detection and assessment of LM deficits.
Study of extremely low frequency electromagnetic fields in infant incubators.
Cermáková, Eleonora
2003-01-01
The aim of the work was to present the results of measurements of extremely low frequency electromagnetic fields (ELF EMF), namely the magnetic flux density, inside infant incubators, and to compare these results with the data published by other authors who point out to a possible association between leukemia or other diseases observed in newborns kept in incubators after the birth and the ELF EMF exposure in the incubator. The measured magnetic flux densities were compared with the reference values for this frequency range indicated in the European Union (EU) recommendations. The repeated measurements in incubators were made with a calibrated magnetometer EFA 300 in the frequency range of 5-30 kHz. Effective values of magnetic flux densities of ELF EMF were determined taking account of the reference values. The results of many repeated measurements showing the values of magnetic flux density in modern incubators with plastic supporting frame, were compared with those obtained in old type incubators with iron skeleton. A power frequency of 50 Hz was detected in the incubator and the ELF EMF values were by over two orders lower than the EU reference values. The paper emphasizes the need to take a special care of newborns kept in incubators even if only the sub-reference values are detected. The EU reference values are intended for the adult human population. A baby in an incubator has much smaller dimensions, higher electric conductivity and maybe trigger another mechanism of response to ELF EMF than that indicated in this paper.
Schimmelmann, Arndt; Qi, Haiping; Coplen, Tyler B; Brand, Willi A; Fong, Jon; Meier-Augenstein, Wolfram; Kemp, Helen F; Toman, Blaza; Ackermann, Annika; Assonov, Sergey; Aerts-Bijma, Anita T; Brejcha, Ramona; Chikaraishi, Yoshito; Darwish, Tamim; Elsner, Martin; Gehre, Matthias; Geilmann, Heike; Gröning, Manfred; Hélie, Jean-François; Herrero-Martín, Sara; Meijer, Harro A J; Sauer, Peter E; Sessions, Alex L; Werner, Roland A
2016-04-19
An international project developed, quality-tested, and determined isotope-δ values of 19 new organic reference materials (RMs) for hydrogen, carbon, and nitrogen stable isotope-ratio measurements, in addition to analyzing pre-existing RMs NBS 22 (oil), IAEA-CH-7 (polyethylene foil), and IAEA-600 (caffeine). These new RMs enable users to normalize measurements of samples to isotope-δ scales. The RMs span a range of δ(2)H(VSMOW-SLAP) values from -210.8 to +397.0 mUr or ‰, for δ(13)C(VPDB-LSVEC) from -40.81 to +0.49 mUr and for δ(15)N(Air) from -5.21 to +61.53 mUr. Many of the new RMs are amenable to gas and liquid chromatography. The RMs include triads of isotopically contrasting caffeines, C16 n-alkanes, n-C20-fatty acid methyl esters (FAMEs), glycines, and l-valines, together with polyethylene powder and string, one n-C17-FAME, a vacuum oil (NBS 22a) to replace NBS 22 oil, and a (2)H-enriched vacuum oil. A total of 11 laboratories from 7 countries used multiple analytical approaches and instrumentation for 2-point isotopic normalization against international primary measurement standards. The use of reference waters in silver tubes allowed direct normalization of δ(2)H values of organic materials against isotopic reference waters following the principle of identical treatment. Bayesian statistical analysis yielded the mean values reported here. New RMs are numbered from USGS61 through USGS78, in addition to NBS 22a. Because of exchangeable hydrogen, amino acid RMs currently are recommended only for carbon- and nitrogen-isotope measurements. Some amino acids contain (13)C and carbon-bound organic (2)H-enrichments at different molecular sites to provide RMs for potential site-specific isotopic analysis in future studies.
Schimmelmann, Arndt; Qi, Haiping; Coplen, Tyler B.; Brand, Willi A.; Fong, Jon; Meier-Augenstein, Wolfram; Kemp, Helen F.; Toman, Blaza; Ackermann, Annika; Assonov, Sergey; Aerts-Bijma, Anita; Brejcha, Ramona; Chikaraishi, Yoshito; Darwish, Tamim; Elsner, Martin; Gehre, Matthias; Geilmann, Heike; Gröning, Manfred; Hélie, Jean-François; Herrero-Martín, Sara; Meijer, Harro A.J.; Sauer, Peter E.; Sessions, Alex L.; Werner, Roland A.
2016-01-01
An international project developed, quality-tested, and determined isotope−δ values of 19 new organic reference materials (RMs) for hydrogen, carbon, and nitrogen stable isotope-ratio measurements, in addition to analyzing pre-existing RMs NBS 22 (oil), IAEA-CH-7 (polyethylene foil), and IAEA-600 (caffeine). These new RMs enable users to normalize measurements of samples to isotope−δ scales. The RMs span a range of δ2HVSMOW-SLAP values from −210.8 to +397.0 mUr or ‰, for δ13CVPDB-LSVEC from −40.81 to +0.49 mUr and for δ15NAir from −5.21 to +61.53 mUr. Many of the new RMs are amenable to gas and liquid chromatography. The RMs include triads of isotopically contrasting caffeines, C16 n-alkanes, n-C20-fatty acid methyl esters (FAMEs), glycines, and l-valines, together with polyethylene powder and string, one n-C17-FAME, a vacuum oil (NBS 22a) to replace NBS 22 oil, and a 2H-enriched vacuum oil. A total of 11 laboratories from 7 countries used multiple analytical approaches and instrumentation for 2-point isotopic normalization against international primary measurement standards. The use of reference waters in silver tubes allowed direct normalization of δ2H values of organic materials against isotopic reference waters following the principle of identical treatment. Bayesian statistical analysis yielded the mean values reported here. New RMs are numbered from USGS61 through USGS78, in addition to NBS 22a. Because of exchangeable hydrogen, amino acid RMs currently are recommended only for carbon- and nitrogen-isotope measurements. Some amino acids contain 13C and carbon-bound organic 2H-enrichments at different molecular sites to provide RMs for potential site-specific isotopic analysis in future studies.
Buehler, James W; Bernet, Patrick M; Ogden, Lydia L
2012-01-01
Funding formulas are commonly used by federal agencies to allocate program funds to states. As one approach to evaluating differences in allocations resulting from alternative formula calculations, we propose the use of a measure derived from the Gini index to summarize differences in allocations relative to 2 referent allocations: one based on equal per-capita funding across states and another based on equal funding per person living in poverty, which we define as the "proportionality of allocation" (PA). These referents reflect underlying values that often shape formula-based allocations for public health programs. The size of state populations serves as a general proxy for the amount of funding needed to support programs across states. While the size of state populations living in poverty is correlated with overall population size, allocations based on states' shares of the national population living in poverty reflect variations in funding need shaped by the association between poverty and multiple adverse health outcomes. The PA measure is a summary of the degree of dispersion in state-specific allocations relative to the referent allocations and provides a quick assessment of the impact of selecting alternative funding formula designs. We illustrate the PA values by adjusting a sample allocation, using various measures of the salary costs and in-state wealth, which might modulate states' needs for federal funding.
Sugimoto, Tadafumi; Robinet, Sébastien; Dulgheru, Raluca; Bernard, Anne; Ilardi, Federica; Contu, Laura; Addetia, Karima; Caballero, Luis; Kacharava, George; Athanassopoulos, George D; Barone, Daniele; Baroni, Monica; Cardim, Nuno; Hagendorff, Andreas; Hristova, Krasimira; Lopez, Teresa; de la Morena, Gonzalo; Popescu, Bogdan A; Penicka, Martin; Ozyigit, Tolga; Rodrigo Carbonero, Jose David; van de Veire, Nico; Von Bardeleben, Ralph Stephan; Vinereanu, Dragos; Zamorano, Jose Luis; Go, Yun Yun; Marchetta, Stella; Nchimi, Alain; Rosca, Monica; Calin, Andreea; Moonen, Marie; Cimino, Sara; Magne, Julien; Cosyns, Bernard; Galli, Elena; Donal, Erwan; Habib, Gilbert; Esposito, Roberta; Galderisi, Maurizio; Badano, Luigi P; Lang, Roberto M; Lancellotti, Patrizio
2018-06-01
To obtain the normal ranges for echocardiographic measurements of left atrial (LA) function from a large group of healthy volunteers accounting for age and gender. A total of 371 (median age 45 years) healthy subjects were enrolled at 22 collaborating institutions collaborating in the Normal Reference Ranges for Echocardiography (NORRE) study of the European Association of Cardiovascular Imaging (EACVI). Left atrial data sets were analysed with a vendor-independent software (VIS) package allowing homogeneous measurements irrespective of the echocardiographic equipment used to acquire data sets. The lowest expected values of LA function were 26.1%, 48.7%, and 41.4% for left atrial strain (LAS), 2D left atrial emptying fraction (LAEF), and 3D LAEF (reservoir function); 7.7%, 24.2%, and -0.53/s for LAS-active, LAEF-active, and LA strain rate during LA contraction (SRa) (pump function) and 12.0% and 21.6% for LAS-passive and LAEF-passive (conduit function). Left atrial reservoir and conduit function were decreased with age while pump function was increased. All indices of reservoir function and all LA strains had no difference in both gender and vendor. However, inter-vendor differences were observed in LA SRa despite the use of VIS. The NORRE study provides contemporary, applicable echocardiographic reference ranges for LA function. Our data highlight the importance of age-specific reference values for LA functions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, L.R.
Much research has been devoted to measurement of total blood volume (TBV) and cardiac output (CO) in humans but not enough effort has been devoted to collection and reduction of results for the purpose of deriving typical or {open_quotes}reference{close_quotes} values. Identification of normal values for TBV and CO is needed not only for clinical evaluations but also for the development of biokinetic models for ultra-short-lived radionuclides used in nuclear medicine (Leggett and Williams 1989). The purpose of this report is to offer reference values for TBV and CO, along with estimates of the associated uncertainties that arise from intra- andmore » inter-subject variation, errors in measurement techniques, and other sources. Reference values are derived for basal supine CO and TBV in reference adult humans, and differences associated with age, sex, body size, body position, exercise, and other circumstances are discussed.« less
Calzada-Contreras, Adriana; Moreno-Hernández, Manuel; Castillo-Torres, Noemi Patricia; Souto-Rosillo, Guadalupe; Hernández-Juárez, Jesús; Ricardo-Moreno, María Tania; Sánchez-Fernández, Maria Guadalupe de Jesús; García-González, América; Majluf-Cruz, Abraham
2012-01-01
The blood coagulation system maintains the blood in a liquid state and bleeding and thrombosis are the manifestations of its malfunction. Blood coagulation laboratory evaluates the physiology of this system. To establish both, the reference values for several tests performed at the blood coagulation laboratory as well as the utility of the pooled plasma to perform these assays. MATERIAL AND: In this descriptive, cross-sectional, randomized study, we collected plasma from Mexican Mestizos. Each pooled plasma was prepared with the plasma from at least 20 blood donors. We performed screening and special tests and the Levey-Jennings graphs were built and interpreted after each pass. Results of the tests were analyzed and their distribution was established using the Kolmogorov-Smirnov test. To establish the reference values we used 95% confidence intervals. We collected 72 pooled plasmas. The distribution for PT, APTT, and TT tests was abnormal. Although the PT test showed a bimodal distribution it was normal for factor VII. The reference values for the hemostatic, anticoagulant, and fibrinolytic factors were different from those suggested by the manufacturers. We established the reference values for the blood coagulation tests in the adult Mexican population. We have shown that the pooled plasma must be used for the screening tests. We suggest that each clinical laboratory should establish its own reference values (at least for the screening tests). To reach this objective, we encourage the use of the pooled plasma.
2012-01-01
Background Pulsed wave (PW) Doppler echocardiography has become a routine non invasive cardiac diagnostic tool in most species. However, evaluation of intracardiac blood flow requires reference values, which are poorly documented in goats. The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy adult Saanen goats. Using a standardised PW Doppler echocardiographic protocol, 10 healthy adult unsedated female Saanen goats were investigated three times at one day intervals by the same observer. Mitral, tricuspid, aortic and pulmonary flows were measured from a right parasternal view, and mitral and aortic flows were also measured from a left parasternal view. The difference between left and right side measurements and the intra-observer inter-day repeatability were tested and then the reference values of PW Doppler echocardiographic parameters in healthy adult female Saanen goats were established. Results As documented in other species, all caprine PW Doppler parameters demonstrated a poor inter-day repeatability and a moderate variability. Tricuspid and pulmonary flows were best evaluated on the right side whereas mitral and aortic flows were best obtained on the left side, and reference values are reported for healthy adult Saanen goats. Conclusions PW Doppler echocardiography allows the measurement of intracardiac blood flow indices in goats. The reference values establishment will help interpreting these indices of cardiac function in clinical cardiac cases and developing animal models for human cardiology research. PMID:23067875
Quinn, Caitlin; Nakyanjo, Neema; Ddaaki, William; Burke, Virginia M; Hutchinson, Naadiya; Kagaayi, Joseph; Wawer, Maria J; Nalugoda, Fred; Kennedy, Caitlin E
2018-01-25
HIV partner notification involves contacting sexual partners of people who test HIV positive and referring them to HIV testing, treatment, and prevention services. To understand values and preferences of key and general populations in Rakai, Uganda, we conducted 6 focus group discussions and 63 in-depth interviews in high prevalence fishing communities and low prevalence mainland communities. Participants included fishermen and sex workers in fishing communities, male and female mainland community members, and healthcare providers. Questions explored three approaches: passive referral, provider referral, and contract referral. Qualitative data were coded and analyzed using a team-based matrix approach. Participants agreed that passive referral was most suitable for primary partners. Provider referral was acceptable in fishing communities for notifying multiple, casual partners. Healthcare providers voiced concerns about limited time, resources, and training for provider-assisted approaches. Options for partner notification may help people overcome barriers to HIV serostatus disclosure and help reach key populations.
Payande, Abolfazl; Tabesh, Hamed; Shakeri, Mohammad Taghi; Saki, Azadeh; Safarian, Mohammad
2013-01-14
Growth charts are widely used to assess children's growth status and can provide a trajectory of growth during early important months of life. The objectives of this study are going to construct growth charts and normal values of weight-for-age for children aged 0 to 5 years using a powerful and applicable methodology. The results compare with the World Health Organization (WHO) references and semi-parametric LMS method of Cole and Green. A total of 70737 apparently healthy boys and girls aged 0 to 5 years were recruited in July 2004 for 20 days from those attending community clinics for routine health checks as a part of a national survey. Anthropometric measurements were done by trained health staff using WHO methodology. The nonparametric quantile regression method obtained by local constant kernel estimation of conditional quantiles curves using for estimation of curves and normal values. The weight-for-age growth curves for boys and girls aged from 0 to 5 years were derived utilizing a population of children living in the northeast of Iran. The results were similar to the ones obtained by the semi-parametric LMS method in the same data. Among all age groups from 0 to 5 years, the median values of children's weight living in the northeast of Iran were lower than the corresponding values in WHO reference data. The weight curves of boys were higher than those of girls in all age groups. The differences between growth patterns of children living in the northeast of Iran versus international ones necessitate using local and regional growth charts. International normal values may not properly recognize the populations at risk for growth problems in Iranian children. Quantile regression (QR) as a flexible method which doesn't require restricted assumptions, proposed for estimation reference curves and normal values.
Payande, Abolfazl; Tabesh, Hamed; Shakeri, Mohammad Taghi; Saki, Azadeh; Safarian, Mohammad
2013-01-01
Introduction: Growth charts are widely used to assess children’s growth status and can provide a trajectory of growth during early important months of life. The objectives of this study are going to construct growth charts and normal values of weight-for-age for children aged 0 to 5 years using a powerful and applicable methodology. The results compare with the World Health Organization (WHO) references and semi-parametric LMS method of Cole and Green. Methods: A total of 70737 apparently healthy boys and girls aged 0 to 5 years were recruited in July 2004 for 20 days from those attending community clinics for routine health checks as a part of a national survey. Anthropometric measurements were done by trained health staff using WHO methodology. The nonparametric quantile regression method obtained by local constant kernel estimation of conditional quantiles curves using for estimation of curves and normal values. Results: The weight-for-age growth curves for boys and girls aged from 0 to 5 years were derived utilizing a population of children living in the northeast of Iran. The results were similar to the ones obtained by the semi-parametric LMS method in the same data. Among all age groups from 0 to 5 years, the median values of children’s weight living in the northeast of Iran were lower than the corresponding values in WHO reference data. The weight curves of boys were higher than those of girls in all age groups. Conclusion: The differences between growth patterns of children living in the northeast of Iran versus international ones necessitate using local and regional growth charts. International normal values may not properly recognize the populations at risk for growth problems in Iranian children. Quantile regression (QR) as a flexible method which doesn’t require restricted assumptions, proposed for estimation reference curves and normal values. PMID:23618470
Properties of colour reference solutions of the European Pharmacopoea in CIE L*a*b* colour space.
Subert, J; Farsa, O; Gajdosová, Z
2006-12-01
The coordinates of CIE L*a*b* uniform colour space have been acquired from the transmitance spectra of colour reference solutions of European Pharmacopoeia (Ph.Eur.). Calculation of colour differences of these solutions from purified water deltaE* gave their values in the range between 0.7 (B9 solution) to 36 (Y1 solution) CIE units. Excluding red colour reference soulutions, deltaE* values did not depend on concentrations of colour compounds linearly. Small deltaE* values founded by the brown and brownish-yellow colour reference solutions of the lowest concentrations can possibly cause some problems of visual examination of the degree of coloration of liquids according to Ph.Eur.
The Geochemical Databases GEOROC and GeoReM - What's New?
NASA Astrophysics Data System (ADS)
Sarbas, B.; Jochum, K. P.; Nohl, U.; Weis, U.
2017-12-01
The geochemical databases GEOROC (http: georoc.mpch-mainz.gwdg.de) and GeoReM (http: georem.mpch-mainz.gwdg.de) are maintained by the Max Planck Institute for Chemistry in Mainz, Germany. Both online databases became crucial tools for geoscientists from different research areas. They are regularly upgraded by new tools and new data from recent publications obtained from a wide range of international journals. GEOROC is a collection of published analyses of volcanic rocks and mantle xenoliths. Since recently, data for plutonic rocks are added. The analyses include major and trace element concentrations, radiogenic and non-radiogenic isotope ratios as well as analytical ages for whole rocks, glasses, minerals and inclusions. Samples come from eleven geological settings and span the whole geological age scale from Archean to Recent. Metadata include, among others, geographic location, rock class and rock type, geological age, degree of alteration, analytical method, laboratory, and reference. The GEOROC web page allows selection of samples by geological setting, geography, chemical criteria, rock or sample name, and bibliographic criteria. In addition, it provides a large number of precompiled files for individual locations, minerals and rock classes. GeoReM is a database collecting information about reference materials of geological and environmental interest, such as rock powders, synthetic and natural glasses as well as mineral, isotopic, biological, river water and seawater reference materials. It contains published data and compilation values (major and trace element concentrations and mass fractions, radiogenic and stable isotope ratios). Metadata comprise, among others, uncertainty, analytical method and laboratory. Reference materials are important for calibration, method validation, quality control and to establish metrological traceability. GeoReM offers six different search strategies: samples or materials (published values), samples (GeoReM preferred values), chemical criteria, chemical criteria based on bibliography, bibliography, as well as methods and institutions.
42 CFR 411.354 - Financial relationship, compensation, and ownership or investment interest.
Code of Federal Regulations, 2010 CFR
2010-10-01
... into account, the volume or value of referrals or other business generated by the referring physician... volume or value of referrals or other business generated by the referring physician for the entity... aggregate compensation that varies with, or takes into account, the volume or value of referrals or other...
The use of reference change values in clinical laboratories.
Bugdayci, Guler; Oguzman, Hamdi; Arattan, Havva Yasemin; Sasmaz, Guler
2015-01-01
The use of Reference Change Values (RCV) has been advocated as very useful for monitoring individuals. Most of these are performed for monitoring individuals in acute situations and for following up the improvement or deterioration of chronic diseases. In our study, we aimed at evaluating the RCV calculation for 24 clinical chemistry analytes widely used in clinical laboratories and the utilization of this data. Twenty-four serum samples were analyzed with Abbott kits (Abbott Laboratories, Abbott Park, IL, USA), manufactured for use with the Architect c8000 (Abbott Laboratories, Abbott Park, IL, USA) auto-analyzer. We calculated RCV using the following formula: RCV = Z x 2 1/2x (CVA2 + CVw2)1/2. Four reference change values (RCV) were calculated for each analyte using four statistical probabilities (0.95, and 0.99, unidirectional and bidirectional). Moreover, by providing an interval after identifying upper and lower limits with the Reference Change Factor (RCF), serially measured tests were calculated by using two formulas: exp (Z x 2 1/2 x (CV(A)2 + CVw2)½/100) for RCF(UP) and (1/RCF(UP)) for RCF(DOWN). RCVs of these analytes were calculated as 14.63% for glucose, 29.88% for urea, 17.75% for ALP, 53.39% for CK, 46.98% for CK-MB, 21.00% amylase, 8.00% for total protein, 8.70% for albumin, 51.08% for total bilirubin, 86.34% for direct bilirubin, 6.40% for calcium, 15.03% for creatinine, 21.47% for urate, 14.19% for total cholesterol, 46.62% for triglyceride, 20.51% for HDL-cholesterol, 29.59% for AST, 46.31% for ALT, 31.54% for GGT, 20.92% for LDH, 19.75% for inorganic phosphate, 3.05% for sodium, 11.75% for potassium, 4.44% for chloride (RCV, p < 0.05, unidirectionally). We suggest using RCV as well as using population-based reference intervals in clinical laboratories. RCV could be available as a tool for making clinical decision, especially when monitoring individuals.
Cost-benefit analysis of the 55-mph speed limit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Forester, T.H.; McNown, R.F.; Singell, L.D.
1984-01-01
This article presents the results of an empirical study which estimates the number of reduced fatalities as a result of the imposed 55-mph speed limit. Time series data for the US from 1952 to 1979 is employed in a regression model capturing the relation between fatalities, average speed, variability of speed, and the speed limit. Also discussed are the alternative approaches to valuing human life and the value of time. Provided is a series of benefit-cost ratios based on alternative measures of the benefits and costs from life saving. The paper concludes that the 55-mph speed limit is not costmore » efficient unless additional time on the highway is valued significantly below levels estimated in the best reasearch on the value of time. 12 references, 1 table.« less
1980-05-01
idlers, etc. Main hydraulic systems including pumps, reservoirs, accumulators, filters, valves , lines, fluid, and supports (Figure 4-40). 4-159 -4...SPEED CORRECTION Ny DN-(VALUES OF N. v VALUES OF KPR VALUES OF *111OPT VALUES OF KPN 4.OC VAL.UE LOC VALVE LOC VALU~E LOC VALUE 1207 _______ 1225...TCVT (t/c)qT 0131 TENN NUMBER OF M 0309 TF REFERRED THRUST AS A 1609 - 1616 FUNCTION OF (T/0) TF1 REFERRED N1 AS A FUNCTION 16k1 - 1648 OF (T/e) TF2
Yin, Li; Yao, Jiqiang; Gardner, Brent P; Chang, Kaifen; Yu, Fahong; Goodenow, Maureen M
2012-01-01
Next Generation sequencing (NGS) applied to human papilloma viruses (HPV) can provide sensitive methods to investigate the molecular epidemiology of multiple type HPV infection. Currently a genotyping system with a comprehensive collection of updated HPV reference sequences and a capacity to handle NGS data sets is lacking. HPV-QUEST was developed as an automated and rapid HPV genotyping system. The web-based HPV-QUEST subtyping algorithm was developed using HTML, PHP, Perl scripting language, and MYSQL as the database backend. HPV-QUEST includes a database of annotated HPV reference sequences with updated nomenclature covering 5 genuses, 14 species and 150 mucosal and cutaneous types to genotype blasted query sequences. HPV-QUEST processes up to 10 megabases of sequences within 1 to 2 minutes. Results are reported in html, text and excel formats and display e-value, blast score, and local and coverage identities; provide genus, species, type, infection site and risk for the best matched reference HPV sequence; and produce results ready for additional analyses.
Designing Targeted Educational Voucher Schemes for the Poor in Developing Countries
NASA Astrophysics Data System (ADS)
Shafiq, M. Najeeb
2010-02-01
A targeted educational voucher scheme (TEVS) is often proposed for the poor in developing countries. Essentially, TEVS involves issuing vouchers to poor households, thus enabling them to pay tuition and fees for their children's schooling at participating non-public schools. However, little is known about TEVS' design in developing countries. This article provides the foundation for constructing a TEVS and conducting subsequent scientific evaluations to support, modify or oppose such a system. Specifically, this article uses three policy instruments to design a TEVS: regulation, support services and finance. Regulation here refers to the rules that must be adhered to by participating households, children and schools. Support services refer to services facilitating the participation of children, households, schools, and financial and political supporters. Finance refers to the value of each voucher, total TEVS costs and sources of finance.
Manganese recycling in the United States in 1998
Jones, Thomas S.
2003-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-163 (trace constituents), M-156 (major constituents), N-67 (nutrient constituents), N-68 (nutrient constituents), P-35 (low ionic strength constituents), and Hg-31 (mercury) -- that were distributed in October 2000 to 126 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 122 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Incorporation of detailed eye model into polygon-mesh versions of ICRP-110 reference phantoms
NASA Astrophysics Data System (ADS)
Tat Nguyen, Thang; Yeom, Yeon Soo; Kim, Han Sung; Wang, Zhao Jun; Han, Min Cheol; Kim, Chan Hyeong; Lee, Jai Ki; Zankl, Maria; Petoussi-Henss, Nina; Bolch, Wesley E.; Lee, Choonsik; Chung, Beom Sun
2015-11-01
The dose coefficients for the eye lens reported in ICRP 2010 Publication 116 were calculated using both a stylized model and the ICRP-110 reference phantoms, according to the type of radiation, energy, and irradiation geometry. To maintain consistency of lens dose assessment, in the present study we incorporated the ICRP-116 detailed eye model into the converted polygon-mesh (PM) version of the ICRP-110 reference phantoms. After the incorporation, the dose coefficients for the eye lens were calculated and compared with those of the ICRP-116 data. The results showed generally a good agreement between the newly calculated lens dose coefficients and the values of ICRP 2010 Publication 116. Significant differences were found for some irradiation cases due mainly to the use of different types of phantoms. Considering that the PM version of the ICRP-110 reference phantoms preserve the original topology of the ICRP-110 reference phantoms, it is believed that the PM version phantoms, along with the detailed eye model, provide more reliable and consistent dose coefficients for the eye lens.
Hosseininasab, Abufazel; Mohammadi, Mohammadreza; Jouzi, Samira; Esmaeilinasab, Maryam; Delavar, Ali
2016-01-01
Objective: This study aimed to provide a normative study documenting how 114 five-seven year-old non-patient Iranian children respond to the Rorschach test. We compared this especial sample to international normative reference values for the Comprehensive System (CS). Method: One hundred fourteen 5- 7- year-old non-patient Iranian children were recruited from public schools. Using five child and adolescent samples from five countries, we compared Iranian Normative Reference Data- based on reference means and standard deviations for each sample. Results: Findings revealed that how the scores in each sample were distributed and how the samples were compared across variables in eight Rorschach Comprehensive System (CS) clusters. We reported all descriptive statistics such as reference mean and standard deviation for all variables. Conclusion: Iranian clinicians could rely on country specific or “local norms” when assessing children. We discourage Iranian clinicians to use many CS scores to make nomothetic, score-based inferences about psychopathology in children and adolescents. PMID:27928247
Blanchette, Marc-André; Rivard, Michèle; Dionne, Clermont E; Hogg-Johnson, Sheilah; Steenstra, Ivan
2017-09-01
Objective To compare the duration of financial compensation and the occurrence of a second episode of compensation of workers with occupational back pain who first sought three types of healthcare providers. Methods We analyzed data from a cohort of 5511 workers who received compensation from the Workplace Safety and Insurance Board for back pain in 2005. Multivariable Cox models controlling for relevant covariables were performed to compare the duration of financial compensation for the patients of each of the three types of first healthcare providers. Logistic regression was used to compare the occurrence of a second episode of compensation over the 2-year follow-up period. Results Compared with the workers who first saw a physician (reference), those who first saw a chiropractor experienced shorter first episodes of 100 % wage compensation (adjusted hazard ratio [HR] = 1.20 [1.10-1.31], P value < 0.001), and the workers who first saw a physiotherapist experienced a longer episode of 100 % compensation (adjusted HR = 0.84 [0.71-0.98], P value = 0.028) during the first 149 days of compensation. The odds of having a second episode of financial compensation were higher among the workers who first consulted a physiotherapist (OR = 1.49 [1.02-2.19], P value = 0.040) rather than a physician (reference). Conclusion The type of healthcare provider first visited for back pain is a determinant of the duration of financial compensation during the first 5 months. Chiropractic patients experience the shortest duration of compensation, and physiotherapy patients experience the longest. These differences raise concerns regarding the use of physiotherapists as gatekeepers for the worker's compensation system. Further investigation is required to understand the between-provider differences.
Upper arm circumference development in Chinese children and adolescents: a pooled analysis.
Tong, Fang; Fu, Tong
2015-05-30
Upper arm development in children is different in different ethnic groups. There have been few reports on upper arm circumference (UAC) at different stages of development in children and adolescents in China. The purpose of this study was to provide a reference for growth with weighted assessment of the overall level of development. Using a pooled analysis, an authoritative journal database search and reports of UAC, we created a new database on developmental measures in children. In conducting a weighted analysis, we compared reference values for 0~60 months of development according to the World Health Organization (WHO) statistics considering gender and nationality and used Z values as interval values for the second sampling to obtain an exponential smooth curve to analyze the mean, standard deviation, and sites of attachment. Ten articles were included in the pooled analysis, and these articles included participants from different areas of China. The point of intersection with the WHO curve was 3.5 years with higher values at earlier ages and lower values at older ages. Boys curve was steeper after puberty. The curves in the studies had a merged line compatible. The Z values of exponential smoothing showed the curves were similar for body weight and had a right normal distribution. The integrated index of UAC in Chinese children and adolescents indicated slightly variations with regions. Exponential curve smoothing was suitable for assessment at different developmental stages.
Determination of reference ranges for elements in human scalp hair.
Druyan, M E; Bass, D; Puchyr, R; Urek, K; Quig, D; Harmon, E; Marquardt, W
1998-06-01
Expected values, reference ranges, or reference limits are necessary to enable clinicians to apply analytical chemical data in the delivery of health care. Determination of references ranges is not straightforward in terms of either selecting a reference population or performing statistical analysis. In light of logistical, scientific, and economic obstacles, it is understandable that clinical laboratories often combine approaches in developing health associated reference values. A laboratory may choose to: 1. Validate either reference ranges of other laboratories or published data from clinical research or both, through comparison of patients test data. 2. Base the laboratory's reference values on statistical analysis of results from specimens assayed by the clinical reference laboratory itself. 3. Adopt standards or recommendations of regulatory agencies and governmental bodies. 4. Initiate population studies to validate transferred reference ranges or to determine them anew. Effects of external contamination and anecdotal information from clinicians may be considered. The clinical utility of hair analysis is well accepted for some elements. For others, it remains in the realm of clinical investigation. This article elucidates an approach for establishment of reference ranges for elements in human scalp hair. Observed levels of analytes from hair specimens from both our laboratory's total patient population and from a physician-defined healthy American population have been evaluated. Examination of levels of elements often associated with toxicity serves to exemplify the process of determining reference ranges in hair. In addition the approach serves as a model for setting reference ranges for analytes in a variety of matrices.
Earned Value Management (EVM) Implementation Handbook
NASA Technical Reports Server (NTRS)
2013-01-01
The purpose of this handbook is to provide Earned Value Management (EVM) guidance for the effective application, implementation, and utilization of EVM on NASA programs, projects, major contracts and subcontracts in a consolidated reference document. EVM is a project management process that effectively integrates a project s scope of work with schedule and cost elements for optimum project planning and control. The goal is to achieve timely and accurate quantification of progress that will facilitate management by exception and enable early visibility into the nature and the magnitude of technical problems as well as the intended course and success of corrective actions.
Earned Value Management (EVM) Implementation Handbook
NASA Technical Reports Server (NTRS)
Terrell, Stefanie M.; Richards, Brad W.
2018-01-01
The purpose of this handbook is to provide Earned Value Management (EVM) guidance for the effective application, implementation, and utilization of EVM on NASA programs, projects, major contracts and subcontracts in a consolidated reference document. EVM is a project management process that effectively integrates a project?s scope of work with schedule and cost elements for optimum project planning and control. The goal is to achieve timely and accurate quantification of progress that will facilitate management by exception and enable early visibility into the nature and the magnitude of technical problems as well as the intended course and success of corrective actions.
Vaccaro, J.J.; Olsen, T.D.
2007-01-01
Unique ID grid with a unique value per Hydrologic Response Unit (HRU) per basin in reference to the estimated ground-water recharge for current conditions in the Yakima Basin Aquifer System, (USGS report SIR 2007-5007). Total 78,144 unique values. This grid made it easy to provide estimates of monthly ground-water recharge for water years 1960-2001in an electronic format for water managers, planners, and hydrologists, that could be related back to a spatially referenced grid by the unique ID.
NASA Astrophysics Data System (ADS)
Kotlarski, Sven; Gutiérrez, José M.; Boberg, Fredrik; Bosshard, Thomas; Cardoso, Rita M.; Herrera, Sixto; Maraun, Douglas; Mezghani, Abdelkader; Pagé, Christian; Räty, Olle; Stepanek, Petr; Soares, Pedro M. M.; Szabo, Peter
2016-04-01
VALUE is an open European network to validate and compare downscaling methods for climate change research (http://www.value-cost.eu). A key deliverable of VALUE is the development of a systematic validation framework to enable the assessment and comparison of downscaling methods. Such assessments can be expected to crucially depend on the existence of accurate and reliable observational reference data. In dynamical downscaling, observational data can influence model development itself and, later on, model evaluation, parameter calibration and added value assessment. In empirical-statistical downscaling, observations serve as predictand data and directly influence model calibration with corresponding effects on downscaled climate change projections. We here present a comprehensive assessment of the influence of uncertainties in observational reference data and of scale-related issues on several of the above-mentioned aspects. First, temperature and precipitation characteristics as simulated by a set of reanalysis-driven EURO-CORDEX RCM experiments are validated against three different gridded reference data products, namely (1) the EOBS dataset (2) the recently developed EURO4M-MESAN regional re-analysis, and (3) several national high-resolution and quality-controlled gridded datasets that recently became available. The analysis reveals a considerable influence of the choice of the reference data on the evaluation results, especially for precipitation. It is also illustrated how differences between the reference data sets influence the ranking of RCMs according to a comprehensive set of performance measures.
Amuamuta, Asmare; Mulu, Wondemagegn; Yimer, Mulat; Zenebe, Yohannes; Adem, Yesuf; Abera, Bayeh; Gebeyehu, Wondemu; Gebregziabher, Yakob
2017-01-01
Background Reference interval is crucial for disease screening, diagnosis, monitoring, progression and treatment efficacy. Due to lack of locally derived reference values for the parameters, clinicians use reference intervals derived from western population. But, studies conducted in different African countries have indicated differences between locally and western derived reference values. Different studies also indicated considerable variation in clinical chemistry reference intervals by several variables such as age, sex, geographical location, environment, lifestyle and genetic variation. Objective This study aimed to determine the reference intervals of common clinical chemistry parameters of the community of Gojjam Zones, Northwest Ethiopia. Method Population based cross-sectional study was conducted from November 2015 to December 2016 in healthy adult populations of Gojjam zone. Data such as, medical history, physical examination and socio-demographic data were collected. In addition, laboratory investigations were undertaken to screen the population. Clinical chemistry parameters were measured using Mindray BS 200 clinical chemistry autoanalyzer as per the manufacturer’s instructions. Descriptive statistics was used to calculate mean, median and 95th percentiles. Independent sample T-test and one way ANOVA were used to see association between variables. Results After careful screening of a total of 799 apparently healthy adults who were consented for this study, complete data from 446 (224 females and 222 males) were included for the analysis. The mean age of both the study participants was 28.8 years. Males had high (P<0.05) mean and 2.5th-97.5th percentile ranges of ALT, AST, ALP, creatinine and direct bilirubin. The reference intervals of amylase, LDH, total protein and total bilirubin were not significantly different between the two sex groups (P>0.05). Mean, median, 95% percentile values of AST, ALP, amylase, LDH, creatinine, total protein, total bilirubin, and direct bilirubin across all age groups of participants were similar (P>0.05). But, there was a significant difference in the value of ALT (P<0.05). The reference intervals of ALT, total protein and creatinine were significantly (P<0.05) high in people having monthly income >1500 ETB compared to those with low monthly income. Significant (P<0.05) higher values of the ALT, ALP and total protein were observed in people living in high land compared to low land residences. Conclusion The study showed that some of the common clinical chemistry parameters reference intervals of healthy adults in Gojjam zones were higher than the reference intervals generated from developed countries. Therefore, strict adherence to the reference values generated in developed countries could lead to inappropriate diagnosis and treatment of patients. There was also variation of reference interval values based on climate, gender, age, monthly income and geographical locations. Therefore, further study is required to establish reference intervals for Ethiopian population. PMID:28886191
Tohidi, Maryam; Ghasemi, Asghar; Hadaegh, Farzad; Derakhshan, Arash; Chary, Abdolreza; Azizi, Fereidoun
2014-04-01
Increased insulin concentration is a surrogate for insulin resistance and early assessment of fasting insulin may help in identifying those who are potentially at high risk of type 2 diabetes, hypertension, and cardiovascular disease. The aim of this study was to determine age- and sex-related reference values for serum insulin and insulin resistance/sensitivity indices in Iranian subjects. Serum insulin levels were measured by electrochemiluminescence immunoassay in 5786 participants of the Tehran Lipid and Glucose Study. After application of exclusion criteria, 309 non-obese healthy subjects (124 men and 185 women), aged 24-83 y, were included. The International Federation of Clinical Chemistry guidelines (non-parametric method) and the robust method were used for determining reference values. Overall 95% reference values for fasting insulin were 1.61-11.37, 2.34-11.98, and 2.11-12.49 μU/mL in men, women, and total population respectively. Mean fasting insulin concentration showed a decreasing trend with age in both genders (p for trend ≤0.001). Age, waist circumference, and systolic blood pressures were biological determinants of fasting insulin in both genders; in addition, insulin was modulated by triglycerides in men and fasting glucose in women. Reference intervals for HOMA1-IR, HOMA2-IR, and QUICKI were 0.63-2.68, 0.40-1.80, and 0.33-0.42, respectively. This study presents the first set of reference values for fasting serum insulin to be 2-12 μU/mL for both genders in a healthy sample of Iranian adults along with the reference values for insulin resistance/sensitivity indices. These values could be used for identifying subjects with insulin resistance in epidemiological and clinical research. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Commonly used reference values underestimate oxygen uptake in healthy, 50-year-old Swedish women.
Genberg, M; Andrén, B; Lind, L; Hedenström, H; Malinovschi, A
2018-01-01
Cardiopulmonary exercise testing (CPET) is the gold standard among clinical exercise tests. It combines a conventional stress test with measurement of oxygen uptake (V O 2 ) and CO 2 production. No validated Swedish reference values exist, and reference values in women are generally understudied. Moreover, the importance of achieved respiratory exchange ratio (RER) and the significance of breathing reserve (BR) at peak exercise in healthy individuals are poorly understood. We compared V O 2 at maximal load (peakV O 2 ) and anaerobic threshold (V O 2@ AT ) in healthy Swedish individuals with commonly used reference values, taking gender into account. Further, we analysed maximal workload and peakV O 2 with regard to peak RER and BR. In all, 181 healthy, 50-year-old individuals (91 women) performed CPET. PeakV O 2 was best predicted using Jones et al. (100·5%), while SHIP reference values underestimated peakV O 2 most: 112·5%. Furthermore, underestimation of peakV O 2 in women was found for all studied reference values (P<0·001) and was largest for SHIP: women had 128% of predicted peakV O 2 , while men had 104%. PeakV O 2 was similar in subjects with peak RER of 1-1·1 and RER > 1·1 (2 328·7 versus 2 176·7 ml min -1 , P = 0·11). Lower BR (≤30%) related to significantly higher peakV O 2 (P<0·001). In conclusion, peakV O 2 was best predicted by Jones. All studied reference values underestimated oxygen uptake in women. No evidence for demanding RER > 1·1 in healthy individuals was found. A lowered BR is probably a normal response to higher workloads in healthy individuals. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Elkhair, Nawal M; Hartmann, Helmut
2010-01-01
The identification of the reference values of Stewart variables and the changes in the acid-base status of the blood and urine in relation to the age after acid-load were studied in desert species of camels. 14 healthy young camels (age: 3-5 months) and 22 adult camels (age: 5-8 years) were used to provide the reference and percentile ranges of the Stewart variables. In the experiments, 24 healthy young camels (age: < 3-5 months) were infused with 5M NH4Cl solution (dose: 1.0 ml/kg) through a permanent intravenous catheter. Venous blood and urine samples were collected before infusion (0 hours). After the start of infusion, venous blood samples were collected at 2, 4, 6, 8 and 24 hours, and urine samples were collected at 8, 24 and 48 hours. Blood and urine samples were used for the determination of the various acid-base parameters, including the non-respiratory Stewart variables. The reference range of serum-[strong ion difference = SID3] was 39-52 mmol/l for all age groups. The reference values of serum-[acid total = A-] were between 10-17 mmol/l for all age groups. Serum-[Atotprotein] and -[Atot-albumin] showed a reference range of 19-24 mmol/I and 20-28 mmol/l, respectively. By 2-8 hours after the NH4Cl-load, the Stewart variables (serum-[SID3] and serum-[A(tot-protein)]) decreased significantly, and as a consequence, the blood pH decreased. Generally, the loaded young camels showed a transient moderate hyperchloraemic acidosis with a slight hypoproteinaemic alkalosis. These malfunctions were accompanied by increased renal fractional excretion of chloride and sodium and decreased urine pH. The identified reference values of the Stewart variables can be used for the clinical diagnosis of acid-base disturbances in camels. With the assistance of the non-respiratory Stewart variables ([SID3] and [Atot]), we can detect the determining influence of strong electrolytes (Na+, K+ and Cl-) and weak acids (proteins, Pi) on the physiological and pathological acid-base status of the animals.
Quantitative Imaging Biomarkers: A Review of Statistical Methods for Computer Algorithm Comparisons
2014-01-01
Quantitative biomarkers from medical images are becoming important tools for clinical diagnosis, staging, monitoring, treatment planning, and development of new therapies. While there is a rich history of the development of quantitative imaging biomarker (QIB) techniques, little attention has been paid to the validation and comparison of the computer algorithms that implement the QIB measurements. In this paper we provide a framework for QIB algorithm comparisons. We first review and compare various study designs, including designs with the true value (e.g. phantoms, digital reference images, and zero-change studies), designs with a reference standard (e.g. studies testing equivalence with a reference standard), and designs without a reference standard (e.g. agreement studies and studies of algorithm precision). The statistical methods for comparing QIB algorithms are then presented for various study types using both aggregate and disaggregate approaches. We propose a series of steps for establishing the performance of a QIB algorithm, identify limitations in the current statistical literature, and suggest future directions for research. PMID:24919829
Farrar, Jerry W.; Long, H. Keith
1996-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for 6 standard reference samples--T-137 (trace constituents), M-136 (major constituents), N-47 (nutrient constituents), N-48 (nutrient constituents), P-25 (low ionic strength constituents), and Hg-21 (mercury)--that were distributed in October 1995 to 149 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 136 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Long, H. Keith; Farrar, Jerry W.
1994-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for five standard reference samples--T-129 (trace constituents), M-130 (major constituents), N-42 (nutrients), P-22 (low ionic strength), Hg-18(mercury),--that were distributed in April 1994 to 157 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 133 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the five reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the five standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Long, H.K.; Farrar, J.W.
1993-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for seven standard reference samples--T-123 (trace constituents), T-125 (trace constituents), M-126 (major constituents), N-38 (nutrients), N-39 (Nutrients), P-20 (precipitation-low ionic strength), and Hg-16 (mercury)--that were distributed in April 1993 to 175 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 131 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the 7 reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the seven standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Farrar, Jerry W.; Chleboun, Kimberly M.
1999-01-01
This report presents the results of the U.S. Geological Survey's analytical evaluation program for 8 standard reference samples -- T-157 (trace constituents), M-150 (major constituents), N-61 (nutrient constituents), N-62 (nutrient constituents), P-32 (low ionic strength constituents), GWT-5 (ground-water trace constituents), GWM- 4 (ground-water major constituents),and Hg-28 (mercury) -- that were distributed in March 1999 to 120 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 111 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the seven reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the 8 standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.
Unification of height systems in the frame of GGOS
NASA Astrophysics Data System (ADS)
Sánchez, Laura
2015-04-01
Most of the existing vertical reference systems do not fulfil the accuracy requirements of modern Geodesy. They refer to local sea surface levels, are stationary (do not consider variations in time), realize different physical height types (orthometric, normal, normal-orthometric, etc.), and their combination in a global frame presents uncertainties at the metre level. To provide a precise geodetic infrastructure for monitoring the Earth system, the Global Geodetic Observing System (GGOS) of the International Association of Geodesy (IAG), promotes the standardization of the height systems worldwide. The main purpose is to establish a global gravity field-related vertical reference system that (1) supports a highly-precise (at cm-level) combination of physical and geometric heights worldwide, (2) allows the unification of all existing local height datums, and (3) guarantees vertical coordinates with global consistency (the same accuracy everywhere) and long-term stability (the same order of accuracy at any time). Under this umbrella, the present contribution concentrates on the definition and realization of a conventional global vertical reference system; the standardization of the geodetic data referring to the existing height systems; and the formulation of appropriate strategies for the precise transformation of the local height datums into the global vertical reference system. The proposed vertical reference system is based on two components: a geometric component consisting of ellipsoidal heights as coordinates and a level ellipsoid as the reference surface, and a physical component comprising geopotential numbers as coordinates and an equipotential surface defined by a conventional W0 value as the reference surface. The definition of the physical component is based on potential parameters in order to provide reference to any type of physical heights (normal, orthometric, etc.). The conversion of geopotential numbers into metric heights and the modelling of the reference surface (geoid or quasigeoid determination) are considered as steps of the realization. The vertical datum unification strategy is based on (1) the physical connection of height datums to determine their discrepancies, (2) joint analysis of satellite altimetry and tide gauge records to determine time variations of sea level at reference tide gauges, (3) combination of geometrical and physical heights in a well-distributed and high-precise reference frame to estimate the relationship between the individual vertical levels and the global one, and (4) analysis of GNSS time series at reference tide gauges to separate crustal movements from sea level changes. The final vertical transformation parameters are provided by the common adjustment of the observation equations derived from these methods.
Normal ranges of fetal nasal bone length during the second trimester in an Iranian population.
Rahimi-Sharbaf, Fatemeh; Tahmasebpour, Ahmad-Reza; Pirjani, Reihaneh; Ghaffari, Saeed Reza; Rahimi-Foroushani, Abbas
2011-04-01
To provide a normal reference range for nasal bone length (NBL) during the second trimester of pregnancy in an Iranian population. This cross-sectional study was performed on 3201 fetuses at 15 to 28 weeks of gestational age (GA). Both singleton and twin fetuses were evaluated. The relationship between NBL and GA was determined and percentile values for each gestational week were provided. NBL measurement was obtained in 98% of singleton and 96% of twin fetuses. There was a linear relationship between GA and NBL both in singleton (R(2) = 0.62) and in twin (R(2) = 0.74) fetuses. There was no significant difference between twins regarding NBL (p = 0.18). We have provided the normal reference range for NBL during the second trimester in an Iranian population. NBL in singleton and twin fetuses is similar and there is no significant difference between twins regarding NBL. Copyright © 2011 John Wiley & Sons, Ltd.
Expedient Metrics to Describe Plant Community Change Across Gradients of Anthropogenic Influence
NASA Astrophysics Data System (ADS)
Marcelino, José A. P.; Weber, Everett; Silva, Luís; Garcia, Patrícia V.; Soares, António O.
2014-11-01
Human influence associated with land use may cause considerable biodiversity losses, namely in oceanic islands such as the Azores. Our goal was to identify plant indicator species across two gradients of increasing anthropogenic influence and management (arborescent and herbaceous communities) and determine similarity between plant communities of uncategorized vegetation plots to those in reference gradients using metrics derived from R programming. We intend to test and provide an expedient way to determine the conservation value of a given uncategorized vegetation plot based on the number of native, endemic, introduced, and invasive indicator species present. Using the metric IndVal, plant taxa with a significant indicator value for each community type in the two anthropogenic gradients were determined. A new metric, ComVal, was developed to assess the similarity of an uncategorized vegetation plot toward a reference community type, based on (i) the percentage of pre-defined indicator species from reference communities present in the vegetation plots, and (ii) the percentage of indicator species, specific to a given reference community type, present in the vegetation plot. Using a data resampling approach, the communities were randomly used as training or validation sets to classify vegetation plots based on ComVal. The percentage match with reference community types ranged from 77 to 100 % and from 79 to 100 %, for herbaceous and arborescent vegetation plots, respectively. Both IndVal and ComVal are part of a suite of useful tools characterizing plant communities and plant community change along gradients of anthropogenic influence without a priori knowledge of their biology and ecology.
Pool power control in remelting systems
Williamson, Rodney L [Albuquerque, NM; Melgaard, David K [Albuquerque, NM; Beaman, Joseph J [Austin, TX
2011-12-13
An apparatus for and method of controlling a remelting furnace comprising adjusting current supplied to an electrode based upon a predetermined pool power reference value and adjusting the electrode drive speed based upon the predetermined pool power reference value.
Liu, Xiaobing; Zhang, Yu; Piao, Jianhua; Mao, Deqian; Li, Yajie; Li, Weidong; Yang, Lichen; Yang, Xiaoguang
2017-03-21
The development of reference values of trace elements is recognized as a fundamental prerequisite for the assessment of trace element nutritional status and health risks. In this study, a total of 1400 pregnant women aged 27.0 ± 4.5 years were randomly selected from the China Nutrition and Health Survey 2010-2012 (CNHS 2010-2012). The concentrations of 14 serum trace elements were determined by high-resolution inductively coupled plasma mass spectrometry. Reference values were calculated covering the central 95% reference intervals (P2.5-P97.5) after excluding outliers by Dixon's test. The overall reference values of serum trace elements were 131.5 (55.8-265.0 μg/dL for iron (Fe), 195.5 (107.0-362.4) μg/dL for copper (Cu), 74.0 (51.8-111.3) μg/dL for zinc (Zn), 22.3 (14.0-62.0) μg/dL for rubidium (Rb), 72.2 (39.9-111.6) μg/L for selenium (Se), 45.9 (23.8-104.3) μg/L for strontium (Sr), 1.8 (1.2-3.6) μg/L for molybdenum (Mo), 2.4 (1.2-8.4) μg/L for manganese (Mn), 1.9 (0.6-9.0) ng/L for lead (Pb), 1.1 (0.3-5.6) ng/L for arsenic (As), 835.6 (219.8-4287.7) ng/L for chromium (Cr), 337.9 (57.0-1130.0) ng/L for cobalt (Co), 193.2 (23.6-2323.1) ng/L for vanadium (V), and 133.7 (72.1-595.1) ng/L for cadmium (Cd). Furthermore, some significant differences in serum trace element reference values were observed between different groupings of age intervals, residences, anthropometric status, and duration of pregnancy. We found that serum Fe, Zn, and Se concentrations significantly decreased, whereas serum Cu, Sr, and Co concentrations elevated progressively compared with reference values of 14 serum trace elements in pregnant Chinese women. The reference values of serum trace elements established could play a key role in the following nutritional status and health risk assessment.
The Logical Problem of Language Change.
1995-07-01
tribution Pi. For the most part we will assume in our simulations that this distribution is uniform on degree-0 ( unembedded ) sentences, exactly as in...following table provides the unembedded (degree- 0) sentences from each of the 8 grammars (languages) obtained by setting the 3 parameters of example 1 to di erent values. The languages are referred to as L1 through L8: 17 18
Energy Emergency Management Information System (EEMIS): Functional requirements
NASA Astrophysics Data System (ADS)
1980-10-01
These guidelines state that in order to create the widest practicable competition, the system's requirements, with few exceptions, must be expressed in functional terms without reference to specific hardware or software products, and that wherever exceptions are made a statement of justification must be provided. In addition, these guidelines set forth a recommended maximum threshold limit of annual contract value for schedule contract procurements.
ERIC Educational Resources Information Center
Chenery, Mary Faeth, Ed.
These papers examine societal forces and demographic trends that will affect private camping in the next decade. Each paper begins with an executive summary. The body of each paper then documents the conclusions and speculates on the implications for camping. Reference lists also are provided. "American Values and Organized Camping" by F. M.…
Assessment and valuation of forest ecosystem services: State of the science review
Seth Binder; Robert G. Haight; Stephen Polasky; Travis Warziniack; Miranda H. Mockrin; Robert L. Deal; Greg Arthaud
2017-01-01
This review focuses on the assessment and economic valuation of ecosystem services from forest ecosystemsâthat is, our ability to predict changes in the quantity and value of ecosystem services as a result of specific forest management decisions. It is aimed at forest economists and managers and intended to provide a useful reference to those interested in developing...
ERIC Educational Resources Information Center
Page, Randy M.; Lee, Ching-Mei; Miao, Nae-Fang
2004-01-01
This study compared consistency of age- and gender-specific self-reported height and weight and calculated body mass index among a sample of high school students in Taipei County, Taiwan to reference values for Taiwanese school-aged youth obtained through national studies. Taipei high school students provided self-reports of height and weight that…
Oh! Web 2.0, Virtual Reference Service 2.0, Tools and Techniques (I): A Basic Approach
ERIC Educational Resources Information Center
Arya, Harsh Bardhan; Mishra, J. K.
2011-01-01
This study targets librarians and information professionals who use Web 2.0 tools and applications with a view to providing snapshots on how Web 2.0 technologies are used. It also aims to identify values and impact that such tools have exerted on libraries and their services, as well as to detect various issues associated with the implementation…
ERIC Educational Resources Information Center
Gulías-González, Roberto; Sánchez-López, Mairena; Olivas-Bravo, Ángel; Solera-Martínez, Montserrat; Martínez-Vizcaíno, Vicente
2014-01-01
Background: Physical fitness is considered an important indicator of health in children. The aims of this study were to (1) provide sex- and age-specific EUROFIT battery levels of fitness in Spanish children; (2) compare Spanish children's fitness levels with those of children from other countries; and (3) determine the percentage of Spanish…
Rep. Matheson, Jim [D-UT-2
2009-01-08
House - 02/04/2009 Referred to the Subcommittee on National Parks, Forests and Public Lands. (All Actions) Notes: For further action, see H.R.146, which became Public Law 111-11 on 3/30/2009. Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Choice by Value Encoding and Value Construction: Processes of Loss Aversion
ERIC Educational Resources Information Center
Willemsen, Martijn C.; Bockenholt, Ulf; Johnson, Eric J.
2011-01-01
Loss aversion and reference dependence are 2 keystones of behavioral theories of choice, but little is known about their underlying cognitive processes. We suggest an additional account for loss aversion that supplements the current account of the value encoding of attributes as gains or losses relative to a reference point, introducing a value…
Karon, Brad S; Wickremasinghe, Andrea C; Lo, Stanley F; Saenger, Amy K; Cook, Walter J
2010-08-01
To determine the relationship between BiliChek TcB (Respironics, Marietta GA) and Doumas reference serum or plasma total bilirubin (TSB). Pooled samples with values assigned by the Doumas reference method were used to establish the relationship between a local laboratory and reference Doumas TSB. We then established the relationship between TcB and TSB in the 3 months before and after reassignment of calibrator setpoints undertaken to match the local laboratory to Doumas reference bilirubin values. Before calibrator setpoint reassignment TSB as measured in our laboratory overestimated Doumas reference bilirubin. After calibrator adjustment laboratory TSB was within 1.7-6.8 micromol/L (0.1-0.4 mg/dL) of Doumas reference values. Mean bias between BiliChek TcB and TSB was 42.8+/-22.2 micromol/L (2.5+/-1.3mg/dL) (n=94) before and 49.6+/-22.2 micromol/L (2.9+/-1.3mg/dL) (n=115) after calibration adjustment. BiliChek TcB significantly overestimates TSB as measured by the Doumas reference method. 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Junction Potentials Bias Measurements of Ion Exchange Membrane Permselectivity.
Kingsbury, Ryan S; Flotron, Sophie; Zhu, Shan; Call, Douglas F; Coronell, Orlando
2018-04-17
Ion exchange membranes (IEMs) are versatile materials relevant to a variety of water and waste treatment, energy production, and industrial separation processes. The defining characteristic of IEMs is their ability to selectively allow positive or negative ions to permeate, which is referred to as permselectivity. Measured values of permselectivity that equal unity (corresponding to a perfectly selective membrane) or exceed unity (theoretically impossible) have been reported for cation exchange membranes (CEMs). Such nonphysical results call into question our ability to correctly measure this crucial membrane property. Because weighing errors, temperature, and measurement uncertainty have been shown to not explain these anomalous permselectivity results, we hypothesized that a possible explanation are junction potentials that occur at the tips of reference electrodes. In this work, we tested this hypothesis by comparing permselectivity values obtained from bare Ag/AgCl wire electrodes (which have no junction) to values obtained from single-junction reference electrodes containing two different electrolytes. We show that permselectivity values obtained using reference electrodes with junctions were greater than unity for CEMs. In contrast, electrodes without junctions always produced permselectivities lower than unity. Electrodes with junctions also resulted in artificially low permselectivity values for AEMs compared to electrodes without junctions. Thus, we conclude that junctions in reference electrodes introduce two biases into results in the IEM literature: (i) permselectivity values larger than unity for CEMs and (ii) lower permselectivity values for AEMs compared to those for CEMs. These biases can be avoided by using electrodes without a junction.
Development of saw palmetto (Serenoa repens) fruit and extract standard reference materials.
Schantz, Michele M; Bedner, Mary; Long, Stephen E; Molloy, John L; Murphy, Karen E; Porter, Barbara J; Putzbach, Karsten; Rimmer, Catherine A; Sander, Lane C; Sharpless, Katherine E; Thomas, Jeanice B; Wise, Stephen A; Wood, Laura J; Yen, James H; Yarita, Takashi; NguyenPho, Agnes; Sorenson, Wendy R; Betz, Joseph M
2008-10-01
As part of a collaboration with the National Institutes of Health's Office of Dietary Supplements and the Food and Drug Administration's Center for Drug Evaluation and Research, the National Institute of Standards and Technology has developed two standard reference materials (SRMs) representing different forms of saw palmetto (Serenoa repens), SRM 3250 Serenoa repens fruit and SRM 3251 Serenoa repens extract. Both of these SRMs have been characterized for their fatty acid and phytosterol content. The fatty acid concentration values are based on results from gas chromatography with flame ionization detection (GC-FID) and mass spectrometry (GC/MS) analysis while the sterol concentration values are based on results from GC-FID and liquid chromatography with mass spectrometry analysis. In addition, SRM 3250 has been characterized for lead content, and SRM 3251 has been characterized for the content of beta-carotene and tocopherols. SRM 3250 (fruit) has certified concentration values for three phytosterols, 14 fatty acids as triglycerides, and lead along with reference concentration values for four fatty acids as triglycerides and 16 free fatty acids. SRM 3251 (extract) has certified concentration values for three phytosterols, 17 fatty acids as triglycerides, beta-carotene, and gamma-tocopherol along with reference concentration values for three fatty acids as triglycerides, 17 fatty acids as free fatty acids, beta-carotene isomers, and delta-tocopherol and information values for two phytosterols. These SRMs will complement other reference materials currently available with concentrations for similar analytes and are part of a series of SRMs being developed for dietary supplements.
Washing the patient: dignity and aesthetic values in nursing care.
Pols, Jeannette
2013-07-01
Dignity is a fundamental concept, but its meaning is not clear. This paper attempts to clarify the term by analysing and reconnecting two meanings of dignity: humanitas and dignitas. Humanitas refers to citizen values that protect individuals as equal to one another. Dignitas refers to aesthetic values embedded in genres of sociality that relate to differences between people. The paper explores these values by way of an empirical ethical analysis of practices of washing psychiatric patients in nursing care. Nurses legitimate the washing of reluctant patients with reference to dignity. The analysis shows the intertwinement of humanitas and dignitas that gives dignity its fundamental meaning. © 2013 John Wiley & Sons Ltd.
Matyar, Selcuk; Goruroglu Ozturk, Ozlem; Ziyanoglu Karacor, Esin; Yuzbasioglu Ariyurek, Sedefgul; Sahin, Gulhan; Kibar, Filiz; Yaman, Akgun; Inal, Tamer
2016-11-01
Neuron-specific enolase (NSE) is a recognized biomarker for the assessment of cerebral injury in neurological disorders. This study aims to report a definitive assessment of the biological variation (BV) components of this biomarker, including within-subject BV (CVI), between-subject BV (CVG), index of individuality (II), and reference change value (RCV), in a cohort of Turkish participants using an experimental protocol. Six blood specimens were collected from each of the 13 apparently healthy volunteers (seven women, six men; ranging in age from 23 to 36) on the same day, every 2 weeks for 2 months. Serum specimens were stored at -20°C until analysis. Neuron-specific enolase levels were evaluated in serum samples using an electrochemiluminescence (ECLIA) immunoassay kit with a Roche Cobas e 411 auto-analyser. ANOVA test was used to calculate the variations. The CVI and CVG for NSE were 21.5% and 28.8%, respectively. Analytical variation (CVA) was calculated as 10.2%. Additionally, II and RCV were calculated as 0.74 and 66% (95% confident interval, CI), respectively. As the performance index (PI) was found to be less than 2 (PI = 0.95), it is concluded that the NSE measurements have a desirable performance for analytical imprecision. Since the II was found to be less than 1 (II: 0.74), the reference values will be of little use. Thus, RCV would provide better information for deciding whether a significant change has occurred. © 2016 Wiley Periodicals, Inc.
Al-Salameh, Abdallah; Croixmarie, Vincent; Masson, Perrine; Corruble, Emmanuelle; Fève, Bruno; Colle, Romain; Ripoll, Laurent; Walther, Bernard; Boursier-Neyret, Claire; Werner, Erwan; Becquemont, Laurent; Chanson, Philippe
2017-01-01
Metabolomic approaches are increasingly used to identify new disease biomarkers, yet normal values of many plasma metabolites remain poorly defined. The aim of this study was to define the “normal” metabolome in healthy volunteers. We included 800 French volunteers aged between 18 and 86, equally distributed according to sex, free of any medication and considered healthy on the basis of their medical history, clinical examination and standard laboratory tests. We quantified 185 plasma metabolites, including amino acids, biogenic amines, acylcarnitines, phosphatidylcholines, sphingomyelins and hexose, using tandem mass spectrometry with the Biocrates AbsoluteIDQ p180 kit. Principal components analysis was applied to identify the main factors responsible for metabolome variability and orthogonal projection to latent structures analysis was employed to confirm the observed patterns and identify pattern-related metabolites. We established a plasma metabolite reference dataset for 144/185 metabolites. Total blood cholesterol, gender and age were identified as the principal factors explaining metabolome variability. High total blood cholesterol levels were associated with higher plasma sphingomyelins and phosphatidylcholines concentrations. Compared to women, men had higher concentrations of creatinine, branched-chain amino acids and lysophosphatidylcholines, and lower concentrations of sphingomyelins and phosphatidylcholines. Elderly healthy subjects had higher sphingomyelins and phosphatidylcholines plasma levels than young subjects. We established reference human metabolome values in a large and well-defined population of French healthy volunteers. This study provides an essential baseline for defining the “normal” metabolome and its main sources of variation. PMID:28278231
Trabado, Séverine; Al-Salameh, Abdallah; Croixmarie, Vincent; Masson, Perrine; Corruble, Emmanuelle; Fève, Bruno; Colle, Romain; Ripoll, Laurent; Walther, Bernard; Boursier-Neyret, Claire; Werner, Erwan; Becquemont, Laurent; Chanson, Philippe
2017-01-01
Metabolomic approaches are increasingly used to identify new disease biomarkers, yet normal values of many plasma metabolites remain poorly defined. The aim of this study was to define the "normal" metabolome in healthy volunteers. We included 800 French volunteers aged between 18 and 86, equally distributed according to sex, free of any medication and considered healthy on the basis of their medical history, clinical examination and standard laboratory tests. We quantified 185 plasma metabolites, including amino acids, biogenic amines, acylcarnitines, phosphatidylcholines, sphingomyelins and hexose, using tandem mass spectrometry with the Biocrates AbsoluteIDQ p180 kit. Principal components analysis was applied to identify the main factors responsible for metabolome variability and orthogonal projection to latent structures analysis was employed to confirm the observed patterns and identify pattern-related metabolites. We established a plasma metabolite reference dataset for 144/185 metabolites. Total blood cholesterol, gender and age were identified as the principal factors explaining metabolome variability. High total blood cholesterol levels were associated with higher plasma sphingomyelins and phosphatidylcholines concentrations. Compared to women, men had higher concentrations of creatinine, branched-chain amino acids and lysophosphatidylcholines, and lower concentrations of sphingomyelins and phosphatidylcholines. Elderly healthy subjects had higher sphingomyelins and phosphatidylcholines plasma levels than young subjects. We established reference human metabolome values in a large and well-defined population of French healthy volunteers. This study provides an essential baseline for defining the "normal" metabolome and its main sources of variation.
NASA Astrophysics Data System (ADS)
Croce, M. P.; Hoover, A. S.; Rabin, M. W.; Bond, E. M.; Wolfsberg, L. E.; Schmidt, D. R.; Ullom, J. N.
2016-08-01
Microcalorimeters with embedded radioisotopes are an emerging category of sensor with advantages over existing methods for isotopic analysis of trace-level nuclear materials. For each nuclear decay, the energy of all decay products captured by the absorber (alpha particles, gamma rays, X-rays, electrons, daughter nuclei, etc.) is measured in one pulse. For alpha-decaying isotopes, this gives a measurement of the total nuclear reaction energy (Q value) and the spectra consist of well-separated, narrow peaks. We have demonstrated a simple mechanical alloying process to create an absorber structure consisting of a gold matrix with small inclusions of a radioactive sample. This absorber structure provides an optimized energy thermalization environment, resulting in high-resolution spectra with minimal tailing. We have applied this process to the analysis of particles collected from the surface of a plutonium metal certified reference material (CRM-126A from New Brunswick Laboratory) and demonstrated isotopic analysis by microcalorimeter Q value spectroscopy. Energy resolution from the Gaussian component of a Bortels function fit was 1.3 keV FWHM at 5244 keV. The collected particles were integrated directly into the detector absorber without any chemical processing. The ^{238}Pu/^{239}Pu and ^{240}Pu/^{239}Pu mass ratios were measured and the results confirmed against the certificate of analysis for the reference material. We also demonstrated inter-element analysis capability by measuring the ^{241}Am/^{239}Pu mass ratio.
Field manual for identifying and preserving high-water mark data
Feaster, Toby D.; Koenig, Todd A.
2017-09-26
This field manual provides general guidance for identifying and collecting high-water marks and is meant to be used by field personnel as a quick reference. The field manual describes purposes for collecting and documenting high-water marks along with the most common types of high-water marks. The manual provides a list of suggested field equipment, describes rules of thumb and best practices for finding high-water marks, and describes the importance of evaluating each high-water mark and assigning a numeric uncertainty value as part of the flagging process. The manual also includes an appendix of photographs of a variety of high-water marks obtained from various U.S. Geological Survey field investigations along with general comments about the logic for the assigned uncertainty values.
On the value of the phenotypes in the genomic era.
Gonzalez-Recio, O; Coffey, M P; Pryce, J E
2014-12-01
Genetic improvement programs around the world rely on the collection of accurate phenotypic data. These phenotypes have an inherent value that can be estimated as the contribution of an additional record to genetic gain. Here, the contribution of phenotypes to genetic gain was calculated using traditional progeny testing (PT) and 2 genomic selection (GS) strategies that, for simplicity, included either males or females in the reference population. A procedure to estimate the theoretical economic contribution of a phenotype to a breeding program is described for both GS and PT breeding programs through the increment in genetic gain per unit of increase in estimated breeding value reliability obtained when an additional phenotypic record is added. The main factors affecting the value of a phenotype were the economic value of the trait, the number of phenotypic records already available for the trait, and its heritability. Furthermore, the value of a phenotype was affected by several other factors, including the cost of establishing the breeding program and the cost of phenotyping and genotyping. The cost of achieving a reliability of 0.60 was assessed for different reference populations for GS. Genomic reference populations of more sires with small progeny group sizes (e.g., 20 equivalent daughters) had a lower cost than those reference populations with either large progeny group sizes for fewer genotyped sires, or female reference populations, unless the heritability was large and the cost of phenotyping exceeded a few hundred dollars; then, female reference populations were preferable from an economic perspective. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Krops, Leonie A; Jaarsma, Eva A; Dijkstra, Pieter U; Geertzen, Jan H B; Dekker, Rienk
2017-01-01
To establish reference values for Health Related Quality of Life (HRQoL) in a Dutch rehabilitation population, and to study effects of patient characteristics, diagnosis and physical activity on HRQoL in this population. Former rehabilitation patients (3169) were asked to fill in a questionnaire including the Dutch version of the RAND-36. Differences between our rehabilitation patients and Dutch reference values were analyzed (t-tests). Effects of patient characteristics, diagnosis and movement intensity on scores on the subscales of the RAND-36 were analyzed using block wise multiple regression analyses. In total 1223 patients (39%) returned the questionnaire. HRQoL was significantly poorer in the rehabilitation patients compared to Dutch reference values on all subscales (p<0.001) except for health change (p = 0.197). Longer time between questionnaire and last treatment was associated with a smaller health change (p = 0.035). Higher age negatively affected physical functioning (p<0.001), social functioning (p = 0.004) and health change (p = 0.001). Diagnosis affected outcomes on all subscales except role limitations physical, and mental health (p ranged <0.001 to 0.643). Higher movement intensity was associated with better outcomes on all subscales except for mental health (p ranged <0.001 to 0.190). HRQoL is poorer in rehabilitation patients compared to Dutch reference values. Physical components of HRQoL are affected by diagnosis. In rehabilitation patients an association between movement intensity and HRQoL was found. For clinical purposes, results of this study can be used as reference values for HRQoL in a rehabilitation setting.
Techniques for Developing Child Dummy Protection Reference Values. Event Report
DOT National Transportation Integrated Search
1996-10-01
The purpose of this report is to present background information and techniques : for developing protection reference values (PRV) to use with child dummies in : out-of-position (OOP) child/air bag interaction testing. Biomechanics experts : agree tha...
Measurement of myocardial native T1 in cardiovascular diseases and norm in 1291 subjects.
Liu, Joanna M; Liu, Alexander; Leal, Joana; McMillan, Fiona; Francis, Jane; Greiser, Andreas; Rider, Oliver J; Myerson, Saul; Neubauer, Stefan; Ferreira, Vanessa M; Piechnik, Stefan K
2017-09-28
Native T1-mapping provides quantitative myocardial tissue characterization for cardiovascular diseases (CVD), without the need for gadolinium. However, its translation into clinical practice is hindered by differences between techniques and the lack of established reference values. We provide typical myocardial T1-ranges for 18 commonly encountered CVDs using a single T1-mapping technique - Shortened Look-Locker Inversion Recovery (ShMOLLI), also used in the large UK Biobank and Hypertrophic Cardiomyopathy Registry study. We analyzed 1291 subjects who underwent CMR (1.5-Tesla, MAGNETOM-Avanto, Siemens Healthcare, Erlangen, Germany) between 2009 and 2016, who had a single CVD diagnosis, with mid-ventricular T1-map assessment. A region of interest (ROI) was placed on native T1-maps in the "most-affected myocardium", characterized by the presence of late gadolinium enhancement (LGE), or regional wall motion abnormalities (RWMA) on cines. Another ROI was placed in the "reference myocardium" as far as possible from LGE/RWMA, and in the septum if no focal abnormality was present. To further define normality, we included native T1 of healthy subjects from an existing dataset after sub-endocardial pixel-erosions. Native T1 of patients with normal CMR (938 ± 21 ms) was similar compared to healthy subjects (941 ± 23 ms). Across all patient groups (57 ± 19 yrs., 65% males), focally affected myocardium had significantly different T1 value compared to reference myocardium (all p < 0.001). In the affected myocardium, cardiac amyloidosis (1119 ± 61 ms) had the highest native T1 compared to normal and all other CVDs, while iron-overload (795 ± 58 ms) and Anderson-Fabry disease (863 ± 23 ms) had the lowest native reference T1 (all p < 0.001). Future studies designed to detect the large T1 differences between affected and reference myocardium are estimated to require small sample-sizes (n < 50). However, studies designed to detect the small T1 differences between reference myocardium in CVDs and healthy controls can require several thousand of subjects. We provide typical T1-ranges for common clinical cardiac conditions in the largest cohort to-date, using ShMOLLI T1-mapping at 1.5 T. Sample-size calculations from this study may be useful for the design of future studies and trials that use T1-mapping as an endpoint.
Determination of the air w-value in proton beams using ionization chambers with gas flow capability.
Moyers, M F; Vatnitsky, S M; Miller, D W; Slater, J M
2000-10-01
The purpose of this work was to determine the w-value of air for protons using the paired gas method. Several plastic- and magnesium-walled chambers were used with air, synthetic air, nitrogen, and argon flowing gases. Using argon as a reference gas, the w-value of air was measured and ranged from 32.7 to 34.5 J/C for protons with energies encountered in radiotherapy. Using nitrogen as a reference gas, the w-value of air ranged from 35.2 to 35.4 J/C over the same range of proton energies. The w-value was found, at a given energy, to be independent of the ion chamber used. The uncertainty in these measurements was estimated at 5.2% at the 2sigma level. This uncertainty was dominated by the 4.4% uncertainty in the w-value of the reference gas.
Pieterse, Arwen H; de Vries, Marieke; Kunneman, Marleen; Stiggelbout, Anne M; Feldman-Stewart, Deb
2013-01-01
Healthcare decisions, particularly those involving weighing benefits and harms that may significantly affect quality and/or length of life, should reflect patients' preferences. To support patients in making choices, patient decision aids and values clarification methods (VCM) in particular have been developed. VCM intend to help patients to determine the aspects of the choices that are important to their selection of a preferred option. Several types of VCM exist. However, they are often designed without clear reference to theory, which makes it difficult for their development to be systematic and internally coherent. Our goal was to provide theory-informed recommendations for the design of VCM. Process theories of decision making specify components of decision processes, thus, identify particular processes that VCM could aim to facilitate. We conducted a review of the MEDLINE and PsycINFO databases and of references to theories included in retrieved papers, to identify process theories of decision making. We selected a theory if (a) it fulfilled criteria for a process theory; (b) provided a coherent description of the whole process of decision making; and (c) empirical evidence supports at least some of its postulates. Four theories met our criteria: Image Theory, Differentiation and Consolidation theory, Parallel Constraint Satisfaction theory, and Fuzzy-trace Theory. Based on these, we propose that VCM should: help optimize mental representations; encourage considering all potentially appropriate options; delay selection of an initially favoured option; facilitate the retrieval of relevant values from memory; facilitate the comparison of options and their attributes; and offer time to decide. In conclusion, our theory-based design recommendations are explicit and transparent, providing an opportunity to test each in a systematic manner. Copyright © 2012 Elsevier Ltd. All rights reserved.
Parker, Lisa
2017-07-01
Values are an important part of evidence-based decision making for health policy: they guide the type of evidence that is collected, how it is interpreted, and how important the conclusions are considered to be. Experts in breast screening (including clinicians, researchers, consumer advocates and senior administrators) hold differing values in relation to what is important in breast screening policy and practice, and committees may find it difficult to incorporate the complexity and variety of values into policy decisions. The decision making tool provided here is intended to assist with this process. The tool is modified from more general frameworks that are intended to assist with ethical decision making in public health, and informed by data drawn from previous empirical studies on values amongst Australian breast screening experts. It provides a structured format for breast screening committees to consider and discuss the values of themselves and others, suggests relevant topics for further inquiry and highlights areas of need for future research into the values of the public. It enables committees to publicly explain and justify their decisions with reference to values, improving transparency and accountability. It is intended to act alongside practices that seek to accommodate the values of individual women in the informed decision making process for personal decision making about participation in breast screening. Copyright © 2017 Elsevier B.V. All rights reserved.
The neck shaft angle: CT reference values of 800 adult hips.
Boese, Christoph Kolja; Jostmeier, Janine; Oppermann, Johannes; Dargel, Jens; Chang, De-Hua; Eysel, Peer; Lechler, Philipp
2016-04-01
A precise understanding of the radiological anatomy and biomechanics as well as reliable reference values of the hip are essential. The primary goal of this study was to provide reference values of the neck-shaft angle (NSA) for adult patients based on the analysis of rotation corrected computed tomography (CT) scans of 800 hips. The secondary aim was to compare these measurements with simulated anteroposterior roentgenograms of the pelvis. Pelvic CT scans of 400 patients (54.3 years, range 18-100 years; 200 female) were reconstructed in the derotated coronal plane of the proximal femur and as CT-based simulated anteroposterior roentgenograms of the pelvis in the anterior pelvic plane. Femora were categorized as coxa vara (<120°), physiologic (≥120° to <135°), and coxa valga (≥135°). Intra- and inter-rater reliability were analyzed. Primary research question: Mean NSA for male adults was 129.6° (range 113.2°-148.2°; SD 5.9°) and 131.9° (range 107.1°-151.9°; SD 6.8°) for females in derotated coronal reconstructions. Age (p < 0.001 in both views) and sex influenced the NSA significantly (p = 0.002 and p < 0.001); no significant differences were found between sides (p = 0.722 and p = 0.955). Overall, an excellent reliability of repeated measurements of one or two observers was found (ICC 0.891-0.995). Secondary research question: NSA values measured in the simulated anteroposterior roentgenogram and the rotation corrected coronal reconstruction differed significantly (p < 0.001). While anteroposterior pelvis radiographs are susceptible to rotational errors, the coronal reconstruction of the proximal femur in the femoral neck plane allows the correct measurement of the NSA.
Liao, Jo-Nan; Chao, Tze-Fan; Kuo, Jen-Yuan; Sung, Kuo-Tzu; Tsai, Jui-Peng; Lo, Chi-In; Lai, Yau-Huei; Su, Cheng-Huang; Hung, Chung-Lieh; Yeh, Hung-I; Chen, Shih-Ann
2017-10-01
Left atrial (LA) function is tightly linked to several cardiovascular diseases and confers key prognostic information. Speckle tracking-based deformation as a feasible and sensitive LA mechanical assessment has proven its clinical significance beyond volume measures; however, the reference values remain largely unknown. We studied 4042 participants undergoing annual cardiovascular survey. Among them, 2812 healthy participants (65% men; mean age, 47.4±9.9 years) were eligible for speckle tracking analysis. Peak atrial longitudinal systolic strain and strain rate (SR) at systolic (SRs), early diastolic (SRe), and late diastolic atrial contraction phases (SRa) were analyzed by dedicated software (EchoPAC, GE) and compared in terms of age, sex, and blood pressure. Overall, women demonstrated higher peak atrial longitudinal systolic strain (39.34±7.99% versus 37.95±7.96%; P<0.001) and showed age-dependent more pronounced peak atrial longitudinal systolic strain functional decay than those of men (P value for interaction, <0.05), with men showing higher SRs and SRa, although lower SRe (all P<0.001). Both increasing age and higher blood pressure were independently associated with deteriorated peak atrial longitudinal systolic strain, SRs, and SRe, although augmented LA SRa, even after accounting for baseline clinical covariates in multivariable models that incorporated LA volume, NT-proBNP (N-terminal pro-B-type natriuretic peptide), or left ventricular E/e' (all P<0.001). Our findings suggest LA mechanical functional decays in association with increasing age and higher blood pressure, which seem to be compensated for by augmentation of atrial pump function. We have also provided age- and sex-stratified reference values for strain and SR based on a large-scale Asian population. © 2017 American Heart Association, Inc.
Chroma Shift and Gamut Shape: Going Beyond Average Color Fidelity and Gamut Area
DOE Office of Scientific and Technical Information (OSTI.GOV)
Royer, Michael P.; Houser, Kevin W.; David, Aurélien
Though sometimes referred to as a two-measure system for evaluating color rendition, IES TM-30-15 includes other key components that go beyond the high-level average values IES Rf and IES Rg. This article focuses on the Color Vector Graphic and Local Chroma Shift (IES Rcs,hj), discussing the calculation methods for these evaluation tools and providing context for the interpretation of the values. It also presents alternatives for quantifying the same characteristics, which can inform the development of future measures. The Color Vector Graphic (CVG) is a visual representation of hue and chroma shifts across different hues. It quickly communicates complex informationmore » about how object colors will be rendered by a light source, although it is difficult or impossible to use for writing a specification. CVGs demonstrate that increases in chroma for certain hues sometimes means a decrease in chroma for other hues, and illustrates hue shifts for intermediate colors. The combination of shifts over different hues can be referred to as gamut shape. Complementing this information are the IES Rcs,hj values, which quantify the average relative chroma shift for samples in each of the 16 hue-angle bins (j) specified in IES TM-30-15. Unlike measures of average color fidelity and gamut area, gamut shape and hue-specific chroma shift are new concepts with no directly-comparable historical references. It will be critical to incorporate the Color Vector Graphic and Local Chroma Shift values into practice because they capture information about color rendition that is impossible to describe with average measures (such as CIE Ra, IES Rf, or IES Rg), but that is critical to understanding human evaluations of color quality in architectural environments.« less
Establishing Normative Reference Values for Standing Broad Jump Among Hungarian Youth.
Saint-Maurice, Pedro F; Laurson, Kelly R; Kaj, Mónika; Csányi, Tamás
2015-06-26
The purpose of this study was to examine age and sex trends in anaerobic power assessed by a standing broad jump and to determine norm-referenced values for youth in Hungary. A sample of 2,427 Hungarian youth (1,360 boys and 1,067 girls) completed the standing broad jump twice, and the highest distance score was recorded. Quantile regression was used to fit standing broad jump trends across linear and quadratic functions of age. Statistical significance was determined with bootstrap confidence intervals and the Wald test with p < .05. Age-by-sex specific centiles were generated and the 50th percentile was used to describe the overall patterns. Standing broad jump scores increased steadily in boys from age 11 through 18 years with a discrete plateau at the end of adolescence. Girls' standing broad jump scores of those who performed above the median increased with age and plateaued later in the adolescence. Both linear and quadratic age terms were statistically significant predictors of standing broad jump trends across age (p < .05), but the relations varied depending on the percentile. The 50th percentile values resulted in 147.0 cm, 162.0 cm, 175.0 cm, 186.0 cm, 195.0 cm, 202.0 cm, 207.0 cm, and 210.0 cm for boys aged 11 to 18 years old, respectively, and 140.0 cm, 143.9 cm, 147.3 cm, 150.0 cm, 152.1 cm, 153.7 cm, 154.6 cm, and 155.0 cm for girls aged 11 to 18 years old, respectively. This study provides normative reference charts that take into account age and sex differences in standing broad jump performance. The proposed reference values can be used to interpret standing broad jump scores in Hungarian youth.
NBL CRM 112-A: A new certified isotopic composition
NASA Astrophysics Data System (ADS)
Thomas, R. B.; Essex, R. M.; Mason, P.
2007-12-01
NBL CRM 112-A Uranium Metal Assay Standard is commonly used as a natural uranium isotopic reference material within the earth science mass spectrometry community. The metal is from the same parent material as NBS SRM 960, the uranyl nitrate solution, CRM 145, and the high-purity uranyl nitrate solution CRM 145-B. Because CRM 112-A has not yet been certified for isotopic composition, it has been assumed that this material has a natural 235U/238U (0.0072527), and the δ234U has been determined by measurement (e.g. -37.1‰; Cheng et al., 2000). These values have been widely used to calibrate the concentration of spikes and standards, and to correct measurements for instrument or mass bias. New, preliminary, isotopic measurements on CRM 145 and CRM 112-A performed at New Brunswick Laboratory suggest that these reference materials have a slightly lower 235U/238U and δ234U than have been commonly used. If this is the case, then data using the accepted values may be slightly biased. The significance of this bias will depend on the uncertainty of the measurement, how the CRM 112-A data is used to correct measurement data, the cited values that were used to correct the data, and the final certified values of the CRM. This fall, New Brunswick Laboratory is certifying the isotopic composition of the CRM 112-A metal using high precision thermal ionization mass spectrometry techniques. Upon completion of certification, the new CRM 112- A standard with certified isotopic ratios will provide the earth science community with a well characterized and traceable reference for calibrating and correcting their mass spectrometry measurement systems.
Shoo, Luke P; Freebody, Kylie; Kanowski, John; Catterall, Carla P
2016-02-01
There is current debate about the potential for secondary regrowth to rescue tropical forests from an otherwise inevitable cascade of biodiversity loss due to land clearing and scant evidence to test how well active restoration may accelerate recovery. We used site chronosequences to compare developmental trajectories of vegetation between self-organized (i.e., spontaneous) forest regrowth and biodiversity plantings (established for ecological restoration, with many locally native tree species at high density) in the Australian wet tropics uplands. Across 28 regrowth sites aged 1-59 years, some structural attributes reached reference rainforest levels within 40 years, whereas wood volume and most tested components of native plant species richness (classified by species' origins, family, and ecological functions) reached less than 50% of reference rainforest values. Development of native tree and shrub richness was particularly slow among species that were wind dispersed or animal dispersed with large (>10 mm) seeds. Many species with animal-dispersed seeds were from near-basal evolutionary lineages that contribute to recognized World Heritage values of the study region. Faster recovery was recorded in 25 biodiversity plantings of 1-25 years in which wood volume developed more rapidly; native woody plant species richness reached values similar to reference rainforest and was better represented across all dispersal modes; and species from near-basal plant families were better (although incompletely) represented. Plantings and regrowth showed slow recovery in species richness of vines and epiphytes and in overall resemblance to forest in species composition. Our results can inform decision making about when and where to invest in active restoration and provide strong evidence that protecting old-growth forest is crucially important for sustaining tropical biodiversity. © 2015 Society for Conservation Biology.
Establishment of new complete blood count reference values for healthy Thai adults.
Wongkrajang, P; Chinswangwatanakul, W; Mokkhamakkun, C; Chuangsuwanich, N; Wesarachkitti, B; Thaowto, B; Laiwejpithaya, S; Komkhum, O
2018-04-28
Laboratory reference ranges are essential for diagnostic orientation and treatment decision. As complete blood count parameters are influenced by various factors, including gender, geographic origin, and ethnic origin, it is important to establish specific hematologic reference values for specific populations. This study was conducted at the Department of Clinical Pathology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand. Blood samples were taken from healthy adults aged 18-60 years that attended a health check-up program at our hospital during February 2015 to July 2015. Hematologic and routine chemistry analysis were performed. Participants were determined to be healthy based on medical history and routine medical examinations. Serum vitamin B12, folate, ferritin, and hemoglobin typing were also analyzed to exclude the possible presence of anemia. A statistically significant difference was observed between males and females for Hb level, hematocrit level, red blood cell count, mean corpuscular hemoglobin concentration, percentage neutrophils, monocytes and eosinophils, and absolute neutrophil, lymphocyte, basophil, and platelet counts. Accordingly, gender-specific reference intervals were established for all complete blood count parameters in healthy Thai adult population. The reference value ranges established in this study reflect significant differences between genders. It is possible that these reference ranges may be generalizable to adults living in Thailand. The findings of this study emphasize the importance of establishing specific hematologic reference values for specific populations. © 2018 John Wiley & Sons Ltd.
FT-IR imaging for quantitative determination of liver fat content in non-alcoholic fatty liver.
Kochan, K; Maslak, E; Chlopicki, S; Baranska, M
2015-08-07
In this work we apply FT-IR imaging of large areas of liver tissue cross-section samples (∼5 cm × 5 cm) for quantitative assessment of steatosis in murine model of Non-Alcoholic Fatty Liver (NAFLD). We quantified the area of liver tissue occupied by lipid droplets (LDs) by FT-IR imaging and Oil Red O (ORO) staining for comparison. Two alternative FT-IR based approaches are presented. The first, straightforward method, was based on average spectra from tissues and provided values of the fat content by using a PLS regression model and the reference method. The second one – the chemometric-based method – enabled us to determine the values of the fat content, independently of the reference method by means of k-means cluster (KMC) analysis. In summary, FT-IR images of large size liver sections may prove to be useful for quantifying liver steatosis without the need of tissue staining.
Air density correction in ionization dosimetry.
Christ, G; Dohm, O S; Schüle, E; Gaupp, S; Martin, M
2004-05-21
Air density must be taken into account when ionization dosimetry is performed with unsealed ionization chambers. The German dosimetry protocol DIN 6800-2 states an air density correction factor for which current barometric pressure and temperature and their reference values must be known. It also states that differences between air density and the attendant reference value, as well as changes in ionization chamber sensitivity, can be determined using a radioactive check source. Both methods have advantages and drawbacks which the paper discusses in detail. Barometric pressure at a given height above sea level can be determined by using a suitable barometer, or data downloaded from airport or weather service internet sites. The main focus of the paper is to show how barometric data from measurement or from the internet are correctly processed. Therefore the paper also provides all the requisite equations and terminological explanations. Computed and measured barometric pressure readings are compared, and long-term experience with air density correction factors obtained using both methods is described.
Herkovits, Jorge; Perez-Coll, Cristina; Herkovits, Francisco D
2002-01-01
The toxicity of 34 environmental samples from potentially polluted and reference stations were evaluated by means of the AMPHITOX test from acute to chronic exposure according to the toxicity found in each sample. The samples were obtained from surface and ground water, leaches, industrial effluents and soils. The data, expressed in acute, short-term chronic and chronic Toxicity Units (TUa, TUstc and TUc) resulted in a maximal value of 1000 TUc, found in a leach, while the lower toxicity value was 1.4 TUa corresponding to two surface water samples. In five samples (four providing from reference places) no toxicity was detected. The results point out the possibility of evaluating the toxicity of a wide diversity of samples by means of AMPHITOX as a customized toxicity test. The fact that almost all samples with suspected toxicity in rivers and streams from the Metropolitan area of Buenos Aires city resulted toxic, indicates the need of enhanced stewardship of chemical substances for environmental and human health protection purposes.
An analysis of how The Irish Times portrayed Irish nursing during the 1999 strike.
Clarke, J; O'Neill, C S
2001-07-01
The aim of this article is to explore the images of nursing that were presented in the media during the recent industrial action by nurses and midwives in the Republic of Ireland. Although both nurses and midwives took industrial strike action, the strike was referred to as 'the nurses' strike' and both nurses and midwives were generally referred to by the generic term 'nurses'. Data were gathered from the printed news media of The Irish Times over a period of one month--4 October to 4 November 1999--which included the nine days of the strike. Although we limited the source of our data to just one newspaper, the findings do provide an image of how nurses and nursing care are viewed by both health professionals and the public. This image appeared to give a higher value to masculine cultural codes and the performance of technical skills, whereas acts associated with feminine cultural codes of caring were considered of lower value.
Intermediate sanctions for healthcare organizations.
Samuels, David G; Shoretz, Morris
2002-09-01
Intermediate sanctions legislation requires that tax-exempt providers take steps to ensure that their senior staff members are compensated at fair-market value. A first-time violation could subject an individual to an excise tax of 25 percent of the compensation amount deemed to be excess benefit. Failure to correct the violation could subject the individual to an excise tax of 200 percent of the excess benefit. Tax-exempt organizations may invoke a rebuttable presumption of reasonableness that compensation levels are appropriate. Tax-exempt providers should refer to IRS guidance regarding steps to ensuring compliance.
Shuttle/spacelab contamination environment and effects handbook
NASA Technical Reports Server (NTRS)
Bareiss, L. E.; Payton, R. M.; Papazian, H. A.
1986-01-01
This handbook is intended to assist users of the Spacelab/Space Transportation System by providing contamination environments and effects information that may be of value in planning, designing, manufacturing, and operating a space flight experiment. A summary of available molecular and particulate contamination data on the Space Transportation System and its facilities is presented. Contamination models, contamination effects, and protection methods information are also presented. In addition to contamination, the effects of the space environments at STS altitudes on spacecraft materials are included. Extensive references, bibliographies, and contacts are provided.
Clark, Samuel A; Hickey, John M; Daetwyler, Hans D; van der Werf, Julius H J
2012-02-09
The theory of genomic selection is based on the prediction of the effects of genetic markers in linkage disequilibrium with quantitative trait loci. However, genomic selection also relies on relationships between individuals to accurately predict genetic value. This study aimed to examine the importance of information on relatives versus that of unrelated or more distantly related individuals on the estimation of genomic breeding values. Simulated and real data were used to examine the effects of various degrees of relationship on the accuracy of genomic selection. Genomic Best Linear Unbiased Prediction (gBLUP) was compared to two pedigree based BLUP methods, one with a shallow one generation pedigree and the other with a deep ten generation pedigree. The accuracy of estimated breeding values for different groups of selection candidates that had varying degrees of relationships to a reference data set of 1750 animals was investigated. The gBLUP method predicted breeding values more accurately than BLUP. The most accurate breeding values were estimated using gBLUP for closely related animals. Similarly, the pedigree based BLUP methods were also accurate for closely related animals, however when the pedigree based BLUP methods were used to predict unrelated animals, the accuracy was close to zero. In contrast, gBLUP breeding values, for animals that had no pedigree relationship with animals in the reference data set, allowed substantial accuracy. An animal's relationship to the reference data set is an important factor for the accuracy of genomic predictions. Animals that share a close relationship to the reference data set had the highest accuracy from genomic predictions. However a baseline accuracy that is driven by the reference data set size and the overall population effective population size enables gBLUP to estimate a breeding value for unrelated animals within a population (breed), using information previously ignored by pedigree based BLUP methods.
Dimai, Hans P
2017-11-01
Dual-energy X-ray absorptiometry (DXA) is a two-dimensional imaging technology developed to assess bone mineral density (BMD) of the entire human skeleton and also specifically of skeletal sites known to be most vulnerable to fracture. In order to simplify interpretation of BMD measurement results and allow comparability among different DXA-devices, the T-score concept was introduced. This concept involves an individual's BMD which is then compared with the mean value of a young healthy reference population, with the difference expressed as a standard deviation (SD). Since the early nineties of the past century, the diagnostic categories "normal, osteopenia, and osteoporosis", as recommended by a WHO working Group, are based on this concept. Thus, DXA is still the globally accepted "gold-standard" method for the noninvasive diagnosis of osteoporosis. Another score obtained from DXA measurement, termed Z-score, describes the number of SDs by which the BMD in an individual differs from the mean value expected for age and sex. Although not intended for diagnosis of osteoporosis in adults, it nevertheless provides information about an individual's fracture risk compared to peers. DXA measurement can either be used as a "stand-alone" means in the assessment of an individual's fracture risk, or incorporated into one of the available fracture risk assessment tools such as FRAX® or Garvan, thus improving the predictive power of such tools. The issue which reference databases should be used by DXA-device manufacturers for T-score reference standards has been recently addressed by an expert group, who recommended use National Health and Nutrition Examination Survey III (NHANES III) databases for the hip reference standard but own databases for the lumbar spine. Furthermore, in men it is recommended use female reference databases for calculation of the T-score and use male reference databases for calculation of Z-score. Copyright © 2017 Elsevier Inc. All rights reserved.
Ramírez-Vélez, Robinson; Martínez, Martin; Correa-Bautista, Jorge E; Lobelo, Felipe; Izquierdo, Mikel; Rodríguez-Rodríguez, Fernando; Cristi-Montero, Carlos
2017-08-01
Ramírez-Vélez, R, Martínez, M, Correa-Bautista, JE, Lobelo, F, Izquierdo, M, Rodríguez-Rodríguez, F, and Cristi-Montero, C. Normative reference of standing long jump for Colombian schoolchildren aged 9-17.9 years: The FUPRECOL study. J Strength Cond Res 31(8): 2083-2090, 2017-The purpose of this study was to generate normative values for the standing long jump (SLJ) test in 9- to 17.9-year olds and to investigate sex and age-group differences. The sample comprised 8,034 healthy Colombian schoolchildren [boys n = 3,488 and girls n = 4,546; mean (SD) age 12.8 (±2.3) years old]. Each participant performed two SLJ. Centile smoothed curves, percentile, and tables for the third, 10th, 25th, 50th, 75th, 90th, and 97th percentiles were calculated using Cole's Lambda-Mu-Sigma method. The 2-way analysis of variance tests and Cohen's d showed that the maximum SLJ (centimeter) was higher in boys than in girls across age groups (p < 0.01), reaching the peak at 13 years. Posthoc analyses within the sexes showed yearly increases in SLJ in all ages. In boys, the 50th percentile SLJ score ranged from 109 to 165 cm. In girls, the 50th percentile jump ranged from 96 to 120 cm. For girls, jump scores increased yearly from age 9 to 12.9 years before reaching a plateau at an age between 13 and 15.9. Our results provide, for the first time, sex- and age-specific SLJ reference values for Colombian schoolchildren aged 9-17.9 years. The normative values presented in this study provide the basis for the determination of the proposed age- and sex-specific standards for the FUPRECOL (Association for Muscular Strength with Early Manifestation of Cardiovascular Disease Risk Factors Among Colombian Children and Adolescents) Study-Physical fitness battery for children and adolescents.