The role of health information technology in care coordination in the United States.
Hsiao, Chun-Ju; King, Jennifer; Hing, Esther; Simon, Alan E
2015-02-01
Examine the extent to which office-based physicians in the United States receive patient health information necessary to coordinate care across settings and determine whether receipt of information needed to coordinate care is associated with use of health information technology (HIT) (defined by presence or absence of electronic health record system and electronic sharing of information). Cross-sectional study using the 2012 National Electronic Health Records Survey (65% weighted response rate). Office-based physicians. Use of HIT and 3 types of patient health information needed to coordinate care. In 2012, 64% of physicians routinely received the results of a patient's consultation with a provider outside of their practice, whereas 46% routinely received a patient's history and reason for a referred consultation from a provider outside of their practice. About 54% of physicians reported routinely receiving a patient's hospital discharge information. In adjusted analysis, significant differences in receiving necessary information were observed by use of HIT. Compared with those not using HIT, a lower percentage of physicians who used an electronic health record system and shared patient health information electronically failed to receive the results of outside consultations or patient's history and reason for a referred consultation. No significant differences were observed for the receipt of hospital discharge information by use of HIT. Among physicians routinely receiving information needed for care coordination, at least 54% of them did not receive the information electronically. Although a higher percentage of physicians using HIT received patient information necessary for care coordination than those who did not use HIT, more than one third did not routinely receive the needed patient information at all.
Droplet actuator analyzer with cartridge
NASA Technical Reports Server (NTRS)
Sturmer, Ryan A. (Inventor); Paik, Philip Y. (Inventor); Srinivasan, Vijay (Inventor); Brafford, Keith R. (Inventor); West, Richard M. (Inventor); Smith, Gregory F. (Inventor); Pollack, Michael G. (Inventor); Pamula, Vamsee K. (Inventor)
2011-01-01
A droplet actuator with cartridge is provided. According to one embodiment, a sample analyzer is provided and includes an analyzer unit comprising electronic or optical receiving means, a cartridge comprising self-contained droplet handling capabilities, and a wherein the cartridge is coupled to the analyzer unit by a means which aligns electronic and/or optical outputs from the cartridge with electronic or optical receiving means on the analyzer unit. According to another embodiment, a sample analyzer is provided and includes a sample analyzer comprising a cartridge coupled thereto and a means of electrical interface and/or optical interface between the cartridge and the analyzer, whereby electrical signals and/or optical signals may be transmitted from the cartridge to the analyzer.
12 CFR 551.110 - May I provide a notice electronically?
Code of Federal Regulations, 2010 CFR
2010-01-01
... use other electronic communications if: (a) The parties agree to use electronic instead of hard copy notices; (b) The parties are able to print or download the notice; (c) Your electronic communications system cannot automatically delete the electronic notice; and (d) Both parties are able to receive...
Code of Federal Regulations, 2010 CFR
2010-10-01
... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION STANDARDS FOR THE ELECTRONIC HEALTH RECORD TECHNOLOGY INCENTIVE PROGRAM Requirements Specific to the... provide that the provider (whether individual or entity) is also given any additional appeals rights that...
12 CFR 41.26 - Delivery of opt-out notices.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Affiliate Marketing § 41.26 Delivery of opt-out notices. (a) In general. The opt-out notice must be provided... consumer may reasonably be expected to receive actual notice if the affiliate providing the notice: (1... agreed to receive electronic disclosures by e-mail from the affiliate providing the notice; or (4) Posts...
12 CFR 41.26 - Delivery of opt-out notices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Affiliate Marketing § 41.26 Delivery of opt-out notices. (a) In general. The opt-out notice must be provided... consumer may reasonably be expected to receive actual notice if the affiliate providing the notice: (1... agreed to receive electronic disclosures by e-mail from the affiliate providing the notice; or (4) Posts...
12 CFR 41.26 - Delivery of opt-out notices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Affiliate Marketing § 41.26 Delivery of opt-out notices. (a) In general. The opt-out notice must be provided... consumer may reasonably be expected to receive actual notice if the affiliate providing the notice: (1... agreed to receive electronic disclosures by e-mail from the affiliate providing the notice; or (4) Posts...
The current state of electronic health record (EHR) use in Oklahoma.
Khaliq, Amir A; Mwachofi, Ari K; Hughes, Danny R; Broyles, Robert W; Wheeler, Denna; Roswell, Robert H
2013-02-01
There is ample evidence of the positive impact of electronic health records (EHR) on operational efficiencies and quality of care. Yet, growth in the adoption of EHR and sharing of information among providers has been slow. The Health Information Technology for Economic and Clinical Health (HITECH) Act of 2009 provides financial incentives for eligible providers to adopt and implement EHR. Until now, little information was available regarding the use of EHR in Oklahoma. Sponsored by the Oklahoma Health Information Exchange Trust (OHIET), this study reveals that the frequency of use of EHR among Oklahoma providers is near the national average. Although a large number of Oklahoma physicians have received Medicaid incentive payments for planned adoption, implementation, or upgrade of EHR systems, relatively few eligible providers in Oklahoma have been certified to receive Medicare incentive payments through the Centers for Medicare and Medicaid Services (CMS) and even fewer have actually received these incentive payments.
Provider acceptance of an automated electronic alert for acute kidney injury
Oh, Janice; Bia, Joshua R.; Ubaid-Ullah, Muhamad; Testani, Jeffrey M.; Wilson, Francis Perry
2016-01-01
Background Clinical decision support systems, including electronic alerts, ideally provide immediate and relevant patient-specific information to improve clinical decision-making. Despite the growing capabilities of such alerts in conjunction with an expanding electronic medical record, there is a paucity of information regarding their perceived usefulness. We surveyed healthcare providers' opinions concerning the practicality and efficacy of a specific text-based automated electronic alert for acute kidney injury (AKI) in a single hospital during a randomized trial of AKI alerts. Methods Providers who had received at least one electronic AKI alert in the previous 6 months, as part of a separate randomized controlled trial (clinicaltrials.gov #01862419), were asked to complete a survey concerning their opinions about this specific AKI alert system. Individual approval of the alert system was defined by a provider's desire to continue receiving the alert after termination of the trial. Results A total of 98 individuals completed the survey, including 62 physicians, 27 pharmacists and 7 non-physician providers. Sixty-nine percent of responders approved the alert, with no significant difference among the various professions (P = 0.28). Alert approval was strongly correlated with the belief that the alerts improved patient care (P < 0.0001), and negatively correlated with the belief that alerts did not provide novel information (P = 0.0001). With each additional 30 days of trial duration, odds of approval decreased by 20% (3–35%) (P = 0.02). Conclusions The alert system was generally well received, although approval waned with time. Approval was correlated with the belief that this type of alert improved patient care. These findings suggest that perceived efficacy is critical to the success of future alert trials. PMID:27478598
Position-insensitive long range inductive power transfer
NASA Astrophysics Data System (ADS)
Kwan, Christopher H.; Lawson, James; Yates, David C.; Mitcheson, Paul D.
2014-11-01
This paper presents results of an improved inductive wireless power transfer system for reliable long range powering of sensors with milliwatt-level consumption. An ultra-low power flyback impedance emulator operating in open loop is used to present the optimal load to the receiver's resonant tank. Transmitter power modulation is implemented in order to maintain constant receiver power and to prevent damage to the receiver electronics caused by excessive received voltage. Received power is steady up to 3 m at around 30 mW. The receiver electronics and feedback system consumes 3.1 mW and so with a transmitter input power of 163.3 W the receiver becomes power neutral at 4.75 m. Such an IPT system can provide a reliable alternative to energy harvesters for supplying power concurrently to multiple remote sensors.
High Bandwidth Optical Links for Micro-Satellite Support
NASA Technical Reports Server (NTRS)
Chao, Tien-Hsin (Inventor); Wilson, Keith E. (Inventor); Coste, Keith (Inventor)
2016-01-01
A method, systems, apparatus and device enable high bandwidth satellite communications. An onboard tracking detector, installed in a low-earth orbit satellite, detects a position of an incoming optical beam received/transmitted from a first ground station of one or more ground stations. Tracker electronics determine orientation information of the incoming optical beam based on the position. Control electronics receive the orientation information from the tracker electronics, and control a waveguide drive electronics. The waveguide drive electronics control a voltage that is provided to an electro-optic waveguide beam steering device. The electro-optic waveguide beam steering device steers an outgoing optical beam to one of the one or more ground stations based on the voltage.
12 CFR 571.26 - Delivery of opt-out notices.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Affiliate Marketing § 571.26 Delivery of opt-out notices. (a) In general. The opt-out notice must be... consumer may reasonably be expected to receive actual notice if the affiliate providing the notice: (1... agreed to receive electronic disclosures by e-mail from the affiliate providing the notice; or (4) Posts...
12 CFR 1022.26 - Delivery of opt-out notices.
Code of Federal Regulations, 2013 CFR
2013-01-01
...) Affiliate Marketing § 1022.26 Delivery of opt-out notices. (a) In general. The opt-out notice must be... consumer may reasonably be expected to receive actual notice if the affiliate providing the notice: (1... agreed to receive electronic disclosures by email from the affiliate providing the notice; or (4) Posts...
12 CFR 1022.26 - Delivery of opt-out notices.
Code of Federal Regulations, 2012 CFR
2012-01-01
...) Affiliate Marketing § 1022.26 Delivery of opt-out notices. (a) In general. The opt-out notice must be... consumer may reasonably be expected to receive actual notice if the affiliate providing the notice: (1... agreed to receive electronic disclosures by email from the affiliate providing the notice; or (4) Posts...
12 CFR 1022.26 - Delivery of opt-out notices.
Code of Federal Regulations, 2014 CFR
2014-01-01
...) Affiliate Marketing § 1022.26 Delivery of opt-out notices. (a) In general. The opt-out notice must be... consumer may reasonably be expected to receive actual notice if the affiliate providing the notice: (1... agreed to receive electronic disclosures by email from the affiliate providing the notice; or (4) Posts...
12 CFR 571.26 - Delivery of opt-out notices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Affiliate Marketing § 571.26 Delivery of opt-out notices. (a) In general. The opt-out notice must be... consumer may reasonably be expected to receive actual notice if the affiliate providing the notice: (1... agreed to receive electronic disclosures by e-mail from the affiliate providing the notice; or (4) Posts...
12 CFR 571.26 - Delivery of opt-out notices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Affiliate Marketing § 571.26 Delivery of opt-out notices. (a) In general. The opt-out notice must be... consumer may reasonably be expected to receive actual notice if the affiliate providing the notice: (1... agreed to receive electronic disclosures by e-mail from the affiliate providing the notice; or (4) Posts...
RF lockout circuit for electronic locking system
NASA Astrophysics Data System (ADS)
Becker, Earl M., Jr.; Miller, Allen
1991-02-01
An electronics lockout circuit was invented that includes an antenna adapted to receive radio frequency signals from a transmitter, and a radio frequency detector circuit which converts the radio frequency signals into a first direct current voltage indicative of the relative strength of the field resulting from the radio frequency signals. The first direct current voltage is supplied to a trigger circuit which compares this direct current voltage to an adjustable direct current reference voltage. This provides a second direct current voltage at the output whenever the amplitude of the first direct current voltage exceeds the amplitude of the reference voltage provided by the comparator circuit. This is supplied to a disconnect relay circuit which, upon receiving a signal from the electronic control unit of an electronic combination lock during the time period at which the second direct current voltage is present, isolates the door strike coil of a security door from the electronic control unit. This prevents signals falsely generated by the electronic control unit because of radio frequency signals in the vicinity of the electronic control unit energizing the door strike coil and accidentally opening a security door.
High speed preamplifier circuit, detection electronics, and radiation detection systems therefrom
Riedel, Richard A [Knoxville, TN; Wintenberg, Alan L [Knoxville, TN; Clonts, Lloyd G [Knoxville, TN; Cooper, Ronald G [Oak Ridge, TN
2010-09-21
A preamplifier circuit for processing a signal provided by a radiation detector includes a transimpedance amplifier coupled to receive a current signal from a detector and generate a voltage signal at its output. A second amplification stage has an input coupled to an output of the transimpedance amplifier for providing an amplified voltage signal. Detector electronics include a preamplifier circuit having a first and second transimpedance amplifier coupled to receive a current signal from a first and second location on a detector, respectively, and generate a first and second voltage signal at respective outputs. A second amplification stage has an input coupled to an output of the transimpedance amplifiers for amplifying the first and said second voltage signals to provide first and second amplified voltage signals. A differential output stage is coupled to the second amplification stage for receiving the first and second amplified voltage signals and providing a pair of outputs from each of the first and second amplified voltage signals. Read out circuitry has an input coupled to receive both of the pair of outputs, the read out circuitry having structure for processing each of the pair of outputs, and providing a single digital output having a time-stamp therefrom.
Centralized Accounting and Electronic Filing Provides Efficient Receivables Collection.
ERIC Educational Resources Information Center
School Business Affairs, 1983
1983-01-01
An electronic filing system makes financial control manageable at Bowling Green State University, Ohio. The system enables quick access to computer-stored consolidated account data and microfilm images of charges, statements, and other billing documents. (MLF)
Are low income patients receiving the benefits of electronic health records? A statewide survey.
Butler, Matthew J; Harootunian, Gevork; Johnson, William G
2013-06-01
There are concerns that physicians serving low-income, Medicaid patients, in the United States are less likely to adopt electronic health records and, if so, that Medicaid patients will be denied the benefits from electronic health record use. This study seeks to determine whether physicians treating Medicaid patients were less likely to have adopted electronic health records. Physician surveys completed during physicians' license renewal process in Arizona were merged with the physician licensing data and Medicaid administrative claims data. Survey responses were received from 50.7 percent (6,780 out of 13,380) of all physicians practicing in Arizona. Physician survey responses were used to identify whether the physician used electronic health records and the degree to which the physician exchanged electronic health records with other health-care providers. Medicaid claims data were used to identify which physicians provided health care to Medicaid beneficiaries. The primary outcome of interest was whether Medicaid providers were more or less likely to have adopted electronic health records. Logistic regression analysis was used to estimate average marginal effects. In multivariate analysis, physicians with 20 or more Medicaid patients during the survey cycle were 4.1 percent more likely to use an electronic health record and 5.2 percent more likely to be able to transmit electronic health records to at least one health-care provider outside of their practice. These effects increase in magnitude when the analysis is restricted to solo practice physicians This is the first study to find a pro-Medicaid gap in electronic health record adoption suggesting that the low income patients served by Arizona's Health Care Cost Containment System are not at a disadvantage with regard to electronic health record access and that Arizona's model of promoting electronic health record adoption merits further study.
Code of Federal Regulations, 2011 CFR
2011-10-01
... STANDARDS FOR THE ELECTRONIC HEALTH RECORD TECHNOLOGY INCENTIVE PROGRAM Requirements Specific to the... in § 447.253(e) of this chapter for a provider or entity to appeal the following issues related to... entity) has an opportunity to challenge the State's determination under this Part by submitting documents...
Healthcare Students' Perceptions of Electronic Feedback through GradeMark®
ERIC Educational Resources Information Center
Watkins, Diane; Dummer, Paul; Hawthorne, Kamila; Cousins, Judy; Emmett, Catherine; Johnson, Mike
2014-01-01
This paper reports on the findings from a study undertaken to explore students' perceptions of the timeliness, accessibility, consistency, and quality of feedback and grading received electronically. The system used was GradeMark®, an electronic tool available through the plagiarism software provider, Turnitin®. 296 students from the Schools of…
High brightness electron accelerator
Sheffield, Richard L.; Carlsten, Bruce E.; Young, Lloyd M.
1994-01-01
A compact high brightness linear accelerator is provided for use, e.g., in a free electron laser. The accelerator has a first plurality of acclerating cavities having end walls with four coupling slots for accelerating electrons to high velocities in the absence of quadrupole fields. A second plurality of cavities receives the high velocity electrons for further acceleration, where each of the second cavities has end walls with two coupling slots for acceleration in the absence of dipole fields. The accelerator also includes a first cavity with an extended length to provide for phase matching the electron beam along the accelerating cavities. A solenoid is provided about the photocathode that emits the electons, where the solenoid is configured to provide a substantially uniform magnetic field over the photocathode surface to minimize emittance of the electons as the electrons enter the first cavity.
Electronically shielded solid state charged particle detector
Balmer, D.K.; Haverty, T.W.; Nordin, C.W.; Tyree, W.H.
1996-08-20
An electronically shielded solid state charged particle detector system having enhanced radio frequency interference immunity includes a detector housing with a detector entrance opening for receiving the charged particles. A charged particle detector having an active surface is disposed within the housing. The active surface faces toward the detector entrance opening for providing electrical signals representative of the received charged particles when the received charged particles are applied to the active surface. A conductive layer is disposed upon the active surface. In a preferred embodiment, a nonconductive layer is disposed between the conductive layer and the active surface. The conductive layer is electrically coupled to the detector housing to provide a substantially continuous conductive electrical shield surrounding the active surface. The inner surface of the detector housing is supplemented with a radio frequency absorbing material such as ferrite. 1 fig.
Electronically shielded solid state charged particle detector
Balmer, David K.; Haverty, Thomas W.; Nordin, Carl W.; Tyree, William H.
1996-08-20
An electronically shielded solid state charged particle detector system having enhanced radio frequency interference immunity includes a detector housing with a detector entrance opening for receiving the charged particles. A charged particle detector having an active surface is disposed within the housing. The active surface faces toward the detector entrance opening for providing electrical signals representative of the received charged particles when the received charged particles are applied to the active surface. A conductive layer is disposed upon the active surface. In a preferred embodiment, a nonconductive layer is disposed between the conductive layer and the active surface. The conductive layer is electrically coupled to the detector housing to provide a substantially continuous conductive electrical shield surrounding the active surface. The inner surface of the detector housing is supplemented with a radio frequency absorbing material such as ferrite.
50 CFR 660.15 - Equipment requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... receivers, computer hardware for electronic fish ticket software and computer hardware for electronic logbook software. (b) Performance and technical requirements for scales used to weigh catch at sea... ticket software provided by Pacific States Marine Fish Commission are required to meet the hardware and...
Scott, Marion W.
1990-01-01
A laser source is operated continuously and modulated periodically (typicy sinusoidally). A receiver imposes another periodic modulation on the received optical signal, the modulated signal being detected by an array of detectors of the integrating type. Range to the target determined by measuring the phase shift of the intensity modulation on the received optical beam relative to a reference. The receiver comprises a photoemitter for converting the reflected, periodically modulated, return beam to an accordingly modulated electron stream. The electron stream is modulated by a local demodulation signal source and subsequently converted back to a photon stream by a detector. A charge coupled device (CCD) array then averages and samples the photon stream to provide an electrical signal in accordance with the photon stream.
Scott, M.W.
1990-06-19
A laser source is operated continuously and modulated periodically (typically sinusoidally). A receiver imposes another periodic modulation on the received optical signal, the modulated signal being detected by an array of detectors of the integrating type. Range to the target determined by measuring the phase shift of the intensity modulation on the received optical beam relative to a reference. The receiver comprises a photoemitter for converting the reflected, periodically modulated, return beam to an accordingly modulated electron stream. The electron stream is modulated by a local demodulation signal source and subsequently converted back to a photon stream by a detector. A charge coupled device (CCD) array then averages and samples the photon stream to provide an electrical signal in accordance with the photon stream. 2 figs.
19 CFR 122.50 - General order merchandise.
Code of Federal Regulations, 2010 CFR
2010-04-01
... appropriate Customs-authorized electronic data interchange system. Failure to provide such notification may...-authorized electronic data interchange system. If the party fails to notify Customs of the unentered... merchandise or baggage to a bonded warehouse certified by the port director as qualified to receive general...
19 CFR 122.50 - General order merchandise.
Code of Federal Regulations, 2011 CFR
2011-04-01
... appropriate Customs-authorized electronic data interchange system. Failure to provide such notification may...-authorized electronic data interchange system. If the party fails to notify Customs of the unentered... merchandise or baggage to a bonded warehouse certified by the port director as qualified to receive general...
Collier, D.M.; Meeks, L.A.; Palmer, J.P.
1961-01-31
S>An electronic multiplier is described for use in analog computers. Two electrical input signals are received; one controls the slope of a saw-tooth voltage wave while the other controls the time duration of the wave. A condenser and diode clamps are provided to sustain the crest voltage reached by the wave, and for storing that voltage to provide an output signal which is a steady d-c voltage.
Providing Health Information to Latino Farmworkers: The Case of the Affordable Care Act.
Arcury, Thomas A; Jensen, Anna; Mann, Mackenzie; Sandberg, Joanne C; Wiggins, Melinda F; Talton, Jennifer W; Hall, Mark A; Quandt, Sara A
2017-01-01
Providing health program information to vulnerable communities, such as Latino farmworkers, is difficult. This analysis describes the manner in which farmworkers receive information about the Affordable Care Act, comparing farmworkers with other Latinos. Interviews were conducted with 100 Latino farmworkers and 100 urban Latino North Carolina residents in 2015. Most farmworkers had received health information from a community organization. Trusted sources for health information were health care providers and community organizations. Sources that would influence decisions to enroll were Latino nurses and doctors, religious leaders, and family members. Traditional media, including oral presentation and printed material at the doctor's office, were preferred by the majority of farmworkers and non-farmworkers. Farmworkers used traditional electronic media: radio, television, and telephone. More non-farmworkers used current electronic media: e-mail and Internet. Latino farmworkers and non-farmworkers prefer traditional media in the context of a health care setting. They are willing to try contemporary electronic media for this information.
78 FR 17663 - Agency Information Collection Activities: Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-22
... institution lenders in order to provide financing of an exporter's foreign accounts receivable. Foreign accounts receivable insured by Ex-Im Bank represent stronger collateral to secure the financing. By.... ADDRESSES: Comments maybe submitted electronically on www.regulations.gov or by mail to Office of Management...
Lin, Angela Yu-Chen; Panchangam, Sri Chandana; Lo, Chao-Chun
2009-04-01
This study provides the first evidence on the influence of the semiconductor and electronics industries on perfluorinated chemicals (PFCs) contamination in receiving rivers. We have quantified ten PFCs, including perfluoroalkyl sulfonates (PFASs: PFBS, PFHxS, PFOS) and perfluoroalkyl carboxylates (PFCAs: PFHxA, PFHpA, PFOA, PFNA, PFDA, PFUnA, PFDoA) in semiconductor, electronic, and optoelectronic industrial wastewaters and their receiving water bodies (Taiwan's Keya, Touchien, and Xiaoli rivers). PFOS was found to be the major constituent in semiconductor wastewaters (up to 0.13 mg/L). However, different PFC distributions were found in electronics plant wastewaters; PFOA was the most significant PFC, contributing on average 72% to the effluent water samples, followed by PFOS (16%) and PFDA (9%). The distribution of PFCs in the receiving rivers was greatly impacted by industrial sources. PFOS, PFOA and PFDA were predominant and prevalent in all the river samples, with PFOS detected at the highest concentrations (up to 5.4 microg/L).
Spohr, Stephanie A.; Taxman, Faye S.; Walters, Scott T.
2015-01-01
Introduction Opportunities to influence behavior through the use of electronic reminders has not been examined in a criminal justice population. The purpose of this study was to assess probationer preferences for short-term goals from a web-based program and evaluate the role of voluntary electronic reminders (e.g., text messaging, email) in achieving early treatment and probation tasks. Methods We used data from drug-involved offenders (n=76) participating in a clinical trial of a 2-session motivational computer program. As part of the program, participants could choose to receive text or email reminders about their probation and treatment goals for the next month. Poisson regression models were utilized to evaluate goal and reminder selection in relation to the days of substance use and treatment attendance at two-month follow-up. Results The most common goals were related to probation and treatment tasks, relationships, and cognitive reappraisals. Forty-five percent of probationers elected to receive electronic goal reminders at Session 1 with a slight increase at Session two (49%). Probationers who opted to receive electronic goal reminders at Session one selected significantly more goals on average (M = 4.4, SD = 2.1) than probationers who did not want reminders (M = 3.4, SD = 1.8), (t = 2.41, p = .019). Reminder selection and total number of goals selected predicted days of substance use and treatment attendance at a two-month follow-up. Probationers who opted not to receive electronic reminders and those who only chose to receive reminders at one visit had more days of substance use compared to those who chose to receive reminders at both visits, 1.66 and 2.31 times respectively. Probationers who chose not to receive electronic reminders attended 56% fewer days of treatment compared to those who chose to receive reminders at both visits. Conclusions People’s choice of short-term goals and reminders can provide advance notification of the likelihood of substance use and treatment initiation. Probation systems might use such information to triage at-risk probationers to a higher level of service, before problems have emerged. PMID:26217929
Spohr, Stephanie A; Taxman, Faye S; Walters, Scott T
2015-12-01
Opportunities to influence behavior through the use of electronic reminders has not been examined in a criminal justice population. The purpose of this study was to assess probationer preferences for short-term goals from a web-based program and evaluate the role of voluntary electronic reminders (e.g., text messaging, email) in achieving early treatment and probation tasks. We used data from drug-involved offenders (n=76) participating in a clinical trial of a 2-session motivational computer program. As part of the program, participants could choose to receive text or email reminders about their probation and treatment goals for the next month. Poisson regression models were utilized to evaluate goal and reminder selection in relation to the days of substance use and treatment attendance at two-month follow-up. The most common goals were related to probation and treatment tasks, relationships, and cognitive reappraisals. Forty-five percent of probationers elected to receive electronic goal reminders at Session 1 with a slight increase at Session two (49%). Probationers who opted to receive electronic goal reminders at Session one selected significantly more goals on average (M=4.4, SD=2.1) than probationers who did not want reminders (M=3.4, SD=1.8), (t=2.41, p=.019). Reminder selection and total number of goals selected predicted days of substance use and treatment attendance at a two-month follow-up. Probationers who opted not to receive electronic reminders and those who only chose to receive reminders at one visit had more days of substance use compared to those who chose to receive reminders at both visits, 1.66 and 2.31 times respectively. Probationers who chose not to receive electronic reminders attended 56% fewer days of treatment compared to those who chose to receive reminders at both visits. People's choice of short-term goals and reminders can provide advance notification of the likelihood of substance use and treatment initiation. Probation systems might use such information to triage at-risk probationers to a higher level of service, before problems have emerged. Copyright © 2015. Published by Elsevier Ltd.
NASA Technical Reports Server (NTRS)
1975-01-01
An engineering model opto-mechanical subsystem for a 10.6-micrometer laser heterodyne receiver is developed, and a CO2 waveguide local oscillator and servo electronics are provided for the receiver. Design goals are presented for the subsystems and overall package design is described. Thermal and mechanical distortion loading tests were performed and the results are included.
Results from the USIP_UH contribution to the BARREL-4 campaign
NASA Astrophysics Data System (ADS)
Behrend, C. C.; Bering, E. A., III; Ehteshami, A.; Fenton, A.; Gamblin, R.; Greer, M.; Mathur, S.; Glennie, C. L.; Velasquez, B.; Marpaung, J.; Lalata, M. C.
2016-12-01
The Undergraduate Student Instrumentation Project (USIP) at the University of Houston sent a team to Kiruna, Sweden to participate with NASA/Dartmouth's BARREL-4 campaign in August 2016. BARREL-4's primary instrument is an MeV x-ray scintillation counter. The team has provided two different experiments to be flown, a dual frequency GPS receiver to calculate total electron content and a Very Low Frequency (VLF) receiver to measure the VLF emissions associated with electron precipitation. TEC is calculated via finding pseudo-ranges comparing the sent and received signals from passing satellites. The VLF receiver has an air-core magnetic loop antenna that utilizes a transformer coupled with an integrating pre-amp which is then recorded to a standard music recorder. The presentation will include a summary of observations.
Electronic Reference Service. SPEC Kit 251.
ERIC Educational Resources Information Center
Goetsch, Lori, Comp.
1999-01-01
The goals of this SPEC Kit were to report on the extent to which ARL (Association of Research Libraries) libraries provide electronic reference services and to offer a snapshot of the types of users reached, questions received, policies established, data-gathering techniques utilized, and innovations implemented. The first section of the kit…
Radiometric Calibration Techniques for Signal-of-Opportunity Reflectometers
NASA Technical Reports Server (NTRS)
Piepmeier, Jeffrey R.; Shah, Rashmi; Deshpande, Manohar; Johnson, Carey
2014-01-01
Bi-static reflection measurements utilizing global navigation satellite service (GNSS) or other signals of opportunity (SoOp) can be used to sense ocean and terrestrial surface properties. End-to-end calibration of GNSS-R has been performed using well-characterized reflection surface (e.g., water), direct path antenna, and receiver gain characterization. We propose an augmented approach using on-board receiver electronics for radiometric calibration of SoOp reflectometers utilizing direct and reflected signal receiving antennas. The method calibrates receiver and correlator gains and offsets utilizing a reference switch and common noise source. On-board electronic calibration sources, such as reference switches, noise diodes and loop-back circuits, have shown great utility in stabilizing total power and correlation microwave radiometer and scatterometer receiver electronics in L-band spaceborne instruments. Application to SoOp instruments is likely to bring several benefits. For example, application to provide short and long time scale calibration stability of the direct path channel, especially in low signal-to-noise ratio configurations, is directly analogous to the microwave radiometer problem. The direct path channel is analogous to the loopback path in a scatterometer to provide a reference of the transmitted power, although the receiver is independent from the reflected path channel. Thus, a common noise source can be used to measure the gain ratio of the two paths. Using these techniques long-term (days to weeks) calibration stability of spaceborne L-band scatterometer and radiometer has been achieved better than 0.1. Similar long-term stability would likely be needed for a spaceborne reflectometer mission to measure terrestrial properties such as soil moisture.
Acoustic enhancement for photo detecting devices
Thundat, Thomas G; Senesac, Lawrence R; Van Neste, Charles W
2013-02-19
Provided are improvements to photo detecting devices and methods for enhancing the sensitivity of photo detecting devices. A photo detecting device generates an electronic signal in response to a received light pulse. An electro-mechanical acoustic resonator, electrically coupled to the photo detecting device, damps the electronic signal and increases the signal noise ratio (SNR) of the electronic signal. Increased photo detector standoff distances and sensitivities will result.
12 CFR 717.26 - Delivery of opt-out notices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... CREDIT REPORTING Affiliate Marketing § 717.26 Delivery of opt-out notices. (a) In general. The opt-out... of actual notice. A consumer may reasonably be expected to receive actual notice if the affiliate... to a consumer who has agreed to receive electronic disclosures by e-mail from the affiliate providing...
12 CFR 334.26 - Delivery of opt-out notices.
Code of Federal Regulations, 2013 CFR
2013-01-01
... POLICY FAIR CREDIT REPORTING Affiliate Marketing § 334.26 Delivery of opt-out notices. (a) In general... expectation of actual notice. A consumer may reasonably be expected to receive actual notice if the affiliate... to a consumer who has agreed to receive electronic disclosures by e-mail from the affiliate providing...
12 CFR 334.26 - Delivery of opt-out notices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... POLICY FAIR CREDIT REPORTING Affiliate Marketing § 334.26 Delivery of opt-out notices. (a) In general... expectation of actual notice. A consumer may reasonably be expected to receive actual notice if the affiliate... to a consumer who has agreed to receive electronic disclosures by e-mail from the affiliate providing...
12 CFR 717.26 - Delivery of opt-out notices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... CREDIT REPORTING Affiliate Marketing § 717.26 Delivery of opt-out notices. (a) In general. The opt-out... of actual notice. A consumer may reasonably be expected to receive actual notice if the affiliate... to a consumer who has agreed to receive electronic disclosures by e-mail from the affiliate providing...
12 CFR 334.26 - Delivery of opt-out notices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... POLICY FAIR CREDIT REPORTING Affiliate Marketing § 334.26 Delivery of opt-out notices. (a) In general... expectation of actual notice. A consumer may reasonably be expected to receive actual notice if the affiliate... to a consumer who has agreed to receive electronic disclosures by e-mail from the affiliate providing...
12 CFR 717.26 - Delivery of opt-out notices.
Code of Federal Regulations, 2013 CFR
2013-01-01
... CREDIT REPORTING Affiliate Marketing § 717.26 Delivery of opt-out notices. (a) In general. The opt-out... of actual notice. A consumer may reasonably be expected to receive actual notice if the affiliate... to a consumer who has agreed to receive electronic disclosures by e-mail from the affiliate providing...
High-k Scattering Receiver Mixer Performance for NSTX-U
NASA Astrophysics Data System (ADS)
Barchfeld, Robert; Riemenschneider, Paul; Domier, Calvin; Luhmann, Neville; Ren, Yang; Kaita, Robert
2016-10-01
The High-k Scattering system detects primarily electron-scale turbulence k θ spectra for studying electron thermal transport in NSTX-U. A 100 mW, 693 GHz probe beam passes through plasma, and scattered power is detected by a 4-pixel quasi optical, mixer array. Remotely controlled receiving optics allows the scattering volume to be located from core to edge with a k θ span of 7 to 40 cm-1. The receiver array features 4 RF diagonal input horns, where the electric field polarization is aligned along the diagonal of a square cross section horn, at 30 mm channel spacing. The local oscillator is provided by a 14.4 GHz source followed by a x48 multiplier chain, giving an intermediate frequency of 1 GHz. The receiver optics receive 4 discreet scattering angles simultaneously, and then focus the signals as 4 parallel signals to their respective horns. A combination of a steerable probe beam, and translating receiver, allows for upward or downward scattering which together can provide information about 2D turbulence wavenumber spectrum. IF signals are digitized and stored for later computer analysis. The performance of the receiver mixers is discussed, along with optical design features to enhance the tuning and performance of the mixers. Work supported in part by U.S. DOE Grant DE-FG02-99ER54518 and DE-AC02-09CH1146.
NASA Astrophysics Data System (ADS)
Jackson-Booth, N.; Parker, J.; Pryse, S. E.; Buckland, R.
2017-12-01
The Electron Density Assimilative Model (EDAM) is an ionospheric model that assimilates data sources into a background model, currently provided by IRI2007, to generate a global, or regional, 3D representation of the ionospheric electron density. In this study, slant total electron content (sTEC) between GPS satellites and 43 ground receivers in Europe were assimilated into EDAM to model the ionospheric electron density over western Europe. For the evaluation of the model an additional ground receiver (the truth station) was considered, which was not used in the assimilation process. Slant total electron contents for this station were calculated through the EDAM model along satellite-to-receiver paths corresponding to those of the observations made by the receiver. The modelled and observed sTEC were compared for each satellite and every day, between September 2002 and August 2003. For the comparison standard deviations of the modelled and observed sTEC were determined. These were used in modified Taylor Diagrams to display the mean-removed rms difference between the model and observations, the correlation between the two data sets and the bias of the modelled data. Taylor diagrams were obtained for the entire year, and each season and month. Results of the comparisons are presented and discussed, with a specific interest in times that show increased rms differences and decreased correlations between the data sets. The effect of the satellite calibration biases on the results are also considered.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Wireless Telecommunications Bureau announces by public notice the implementation of a third-party database...) Provide an electronic copy of an interference analysis to the third-party database manager which...-party database managers shall receive and retain the interference analyses electronically and make them...
Code of Federal Regulations, 2012 CFR
2012-10-01
... Wireless Telecommunications Bureau announces by public notice the implementation of a third-party database...) Provide an electronic copy of an interference analysis to the third-party database manager which...-party database managers shall receive and retain the interference analyses electronically and make them...
Code of Federal Regulations, 2010 CFR
2010-10-01
... Wireless Telecommunications Bureau announces by public notice the implementation of a third-party database...) Provide an electronic copy of an interference analysis to the third-party database manager which...-party database managers shall receive and retain the interference analyses electronically and make them...
Code of Federal Regulations, 2013 CFR
2013-10-01
... Wireless Telecommunications Bureau announces by public notice the implementation of a third-party database...) Provide an electronic copy of an interference analysis to the third-party database manager which...-party database managers shall receive and retain the interference analyses electronically and make them...
Code of Federal Regulations, 2011 CFR
2011-10-01
... Wireless Telecommunications Bureau announces by public notice the implementation of a third-party database...) Provide an electronic copy of an interference analysis to the third-party database manager which...-party database managers shall receive and retain the interference analyses electronically and make them...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-09
... financial condition, as disclosed in its most recent balance sheet, available for inspection by any bona... delivering their balance sheet, in paper or electronic form, to customers who request it. Additionally, if the delivery is electronic, the requesting customer must provide consent to receive the balance sheet...
Merrill, Frank E.; Morris, Christopher
2005-05-17
A system capable of performing radiography using a beam of electrons. Diffuser means receive a beam of electrons and diffuse the electrons before they enter first matching quadrupoles where the diffused electrons are focused prior to the diffused electrons entering an object. First imaging quadrupoles receive the focused diffused electrons after the focused diffused electrons have been scattered by the object for focusing the scattered electrons. Collimator means receive the scattered electrons and remove scattered electrons that have scattered to large angles. Second imaging quadrupoles receive the collimated scattered electrons and refocus the collimated scattered electrons and map the focused collimated scattered electrons to transverse locations on an image plane representative of the electrons' positions in the object.
Model based Computerized Ionospheric Tomography in space and time
NASA Astrophysics Data System (ADS)
Tuna, Hakan; Arikan, Orhan; Arikan, Feza
2018-04-01
Reconstruction of the ionospheric electron density distribution in space and time not only provide basis for better understanding the physical nature of the ionosphere, but also provide improvements in various applications including HF communication. Recently developed IONOLAB-CIT technique provides physically admissible 3D model of the ionosphere by using both Slant Total Electron Content (STEC) measurements obtained from a GPS satellite - receiver network and IRI-Plas model. IONOLAB-CIT technique optimizes IRI-Plas model parameters in the region of interest such that the synthetic STEC computations obtained from the IRI-Plas model are in accordance with the actual STEC measurements. In this work, the IONOLAB-CIT technique is extended to provide reconstructions both in space and time. This extension exploits the temporal continuity of the ionosphere to provide more reliable reconstructions with a reduced computational load. The proposed 4D-IONOLAB-CIT technique is validated on real measurement data obtained from TNPGN-Active GPS receiver network in Turkey.
77 FR 24764 - Visual-Manual NHTSA Driver Distraction Guidelines for In-Vehicle Electronic Devices
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-25
... provided a 60-day comment period. We received a petition from the Alliance of Automobile Manufacturers...). We provided a 60-day comment period. In a petition dated March 9, 2012,\\1\\ the Alliance of Automobile...
Appendage mountable electronic devices conformable to surfaces
Rogers, John; Ying, Ming; Bonifas, Andrew; Lu, Nanshu
2017-01-24
Disclosed are appendage mountable electronic systems and related methods for covering and conforming to an appendage surface. A flexible or stretchable substrate has an inner surface for receiving an appendage, including an appendage having a curved surface, and an opposed outer surface that is accessible to external surfaces. A stretchable or flexible electronic device is supported by the substrate inner and/or outer surface, depending on the application of interest. The electronic device in combination with the substrate provides a net bending stiffness to facilitate conformal contact between the inner surface and a surface of the appendage provided within the enclosure. In an aspect, the system is capable of surface flipping without adversely impacting electronic device functionality, such as electronic devices comprising arrays of sensors, actuators, or both sensors and actuators.
Estimation of total electron content (TEC) using spaceborne GPS measurements
NASA Astrophysics Data System (ADS)
Choi, Key-Rok; Lightsey, E. Glenn
2008-09-01
TerraSAR-X (TSX), a high-resolution interferometric Synthetic Aperture Radar (SAR) mission from DLR (German Aerospace Center, Deutsches Zentrum für Luft-und Raumfahrt), was successfully launched into orbit on June 15, 2007. It includes a dual-frequency GPS receiver called IGOR (Integrated GPS Occultation Receiver), which is a heritage NASA/JPL BlackJack receiver. The software for the TSX IGOR receiver was specially-modified software developed at UT/CSR. This software was upgraded to provide enhanced occultation capabilities. This paper describes total electron content (TEC) estimation using simulation data and onboard GPS data of TerraSAR-X. The simulated GPS data were collected using the IGOR Engineering Model (EM) in the laboratory and the onboard GPS data were collected from the IGOR Flight Model (FM) on TSX. To estimate vertical total electron content (vTEC) for the simulation data, inter-frequency biases (IFB) were estimated using the "carrier to code leveling process." For the onboard GPS data, IFBs of GPS satellites were retrieved from the navigation message and applied to the measurements.
A 94 GHz RF Electronics Subsystem for the CloudSat Cloud Profiling Radar
NASA Technical Reports Server (NTRS)
LaBelle, Remi C.; Girard, Ralph; Arbery, Graham
2003-01-01
The CloudSat spacecraft, scheduled for launch in 2004, will carry the 94 GHz Cloud Profiling Radar (CPR) instrument. The design, assembly and test of the flight Radio Frequency Electronics Subsystem (RFES) for this instrument has been completed and is presented here. The RFES consists of an Upconverter (which includes an Exciter and two Drive Amplifiers (DA's)), a Receiver, and a Transmitter Calibrator assembly. Some key performance parameters of the RFES are as follows: dual 100 mW pulse-modulated drive outputs at 94 GHz, overall Receiver noise figure < 5.0 dB, a highly stable W-band noise source to provide knowledge accuracy of Receiver gain of < 0.4 dB over the 2 year mission life, and a W-band peak power detector to monitor the transmitter output power to within 0.5 dB over life. Some recent monolithic microwave integrated circuit (MMIC) designs were utilized which implement the DA's in 0.1 micron GaAs high electron-mobility transistor (HEMT) technology and the Receiver low-noise amplifier (LNA) in 0.1 micron InP HEMT technology.
4D computerized ionospheric tomography by using GPS measurements and IRI-Plas model
NASA Astrophysics Data System (ADS)
Tuna, Hakan; Arikan, Feza; Arikan, Orhan
2016-07-01
Ionospheric imaging is an important subject in ionospheric studies. GPS based TEC measurements provide very accurate information about the electron density values in the ionosphere. However, since the measurements are generally very sparse and non-uniformly distributed, computation of 3D electron density estimation from measurements alone is an ill-defined problem. Model based 3D electron density estimations provide physically feasible distributions. However, they are not generally compliant with the TEC measurements obtained from GPS receivers. In this study, GPS based TEC measurements and an ionosphere model known as International Reference Ionosphere Extended to Plasmasphere (IRI-Plas) are employed together in order to obtain a physically accurate 3D electron density distribution which is compliant with the real measurements obtained from a GPS satellite - receiver network. Ionospheric parameters input to the IRI-Plas model are perturbed in the region of interest by using parametric perturbation models such that the synthetic TEC measurements calculated from the resultant 3D electron density distribution fit to the real TEC measurements. The problem is considered as an optimization problem where the optimization parameters are the parameters of the parametric perturbation models. Proposed technique is applied over Turkey, on both calm and storm days of the ionosphere. Results show that the proposed technique produces 3D electron density distributions which are compliant with IRI-Plas model, GPS TEC measurements and ionosonde measurements. The effect of the GPS receiver station number on the performance of the proposed technique is investigated. Results showed that 7 GPS receiver stations in a region as large as Turkey is sufficient for both calm and storm days of the ionosphere. Since the ionization levels in the ionosphere are highly correlated in time, the proposed technique is extended to the time domain by applying Kalman based tracking and smoothing approaches onto the obtained results. Combining Kalman methods with the proposed 3D CIT technique creates a robust 4D ionospheric electron density estimation model, and has the advantage of decreasing the computational cost of the proposed method. Results applied on both calm and storm days of the ionosphere show that, new technique produces more robust solutions especially when the number of GPS receiver stations in the region is small. This study is supported by TUBITAK 114E541, 115E915 and Joint TUBITAK 114E092 and AS CR 14/001 projects.
Power converter having improved EMI shielding
Beihoff, Bruce C.; Kehl, Dennis L.; Gettelfinger, Lee A.; Kaishian, Steven C.; Phillips, Mark G.; Radosevich, Lawrence D.
2006-06-13
EMI shielding is provided for power electronics circuits and the like via a direct-mount reference plane support and shielding structure. The thermal support may receive one or more power electronic circuits. The support may aid in removing heat from the circuits through fluid circulating through the support. The support forms a shield from both external EMI/RFI and from interference generated by operation of the power electronic circuits. Features may be provided to permit and enhance connection of the circuitry to external circuitry, such as improved terminal configurations. Modular units may be assembled that may be coupled to electronic circuitry via plug-in arrangements or through interface with a backplane or similar mounting and interconnecting structures.
Cooled electrical terminal assembly and device incorporating same
Beihoff, Bruce C.; Radosevich, Lawrence D.; Phillips, Mark G.; Kehl, Dennis L.; Kaishian, Steven C.; Kannenberg, Daniel G.
2006-08-22
A terminal structure provides interfacing with power electronics circuitry and external circuitry. The thermal support may receive one or more power electronic circuits. The support may aid in removing heat from the terminal structure and the circuits through fluid circulating through the support. The support may form a shield from both external EMI/RFI and from interference generated by operation of the power electronic circuits. Features may be provided to permit and enhance connection of the circuitry to external circuitry, such as improved terminal configurations. Modular units may be assembled that may be coupled to electronic circuitry via plug-in arrangements or through interface with a backplane or similar mounting and interconnecting structures.
Power converter connection configuration
Beihoff, Bruce C.; Kehl, Dennis L.; Gettelfinger, Lee A.; Kaishian, Steven C.; Phillips, Mark G.; Radosevich, Lawrence D.
2008-11-11
EMI shielding is provided for power electronics circuits and the like via a direct-mount reference plane support and shielding structure. The thermal support may receive one or more power electronic circuits. The support may aid in removing heat from the circuits through fluid circulating through the support. The support forms a shield from both external EMI/RFI and from interference generated by operation of the power electronic circuits. Features may be provided to permit and enhance connection of the circuitry to external circuitry, such as improved terminal configurations. Modular units may be assembled that may be coupled to electronic circuitry via plug-in arrangements or through interface with a backplane or similar mounting and interconnecting structures.
Cooled electrical terminal assembly and device incorporating same
Beihoff, Bruce C.; Radosevich, Lawrence D.; Phillips, Mark G.; Kehl, Dennis L.; Kaishian, Steven C.; Kannenberg, Daniel G.
2005-05-24
A terminal structure provides interfacing with power electronics circuitry and external circuitry. The thermal support may receive one or more power electronic circuits. The support may aid in removing heat from the terminal structure and the circuits through fluid circulating through the support. The support may form a shield from both external EMI/RFI and from interference generated by operation of the power electronic circuits. Features may be provided to permit and enhance connection of the circuitry to external circuitry, such as improved terminal configurations. Modular units may be assembled that may be coupled to electronic circuitry via plug-in arrangements or through interface with a backplane or similar mounting and interconnecting structures.
Zieve, Garret G; Richardson, Laura P; Katzman, Katherine; Spielvogle, Heather; Whitehouse, Sandy; McCarty, Carolyn A
2017-07-20
Electronic health screening tools for primary care present an opportunity to go beyond data collection to provide education and feedback to adolescents in order to motivate behavior change. However, there is limited research to guide feedback message development. The aim of this study was to explore youth perceptions of and preferences for receiving personalized feedback for multiple health risk behaviors and reinforcement for health promoting behaviors from an electronic health screening tool for primary care settings, using qualitative methodology. In total, 31 adolescents aged 13-18 years completed the screening tool, received the electronic feedback, and subsequently participated in individual, semistructured, qualitative interviews lasting approximately 60 min. Participants were queried about their overall impressions of the tool, perceptions regarding various types of feedback messages, and additional features that would help motivate health behavior change. Using thematic analysis, interview transcripts were coded to identify common themes expressed across participants. Overall, the tool was well-received by participants who perceived it as a way to enhance-but not replace-their interactions with providers. They appreciated receiving nonjudgmental feedback from the tool and responded positively to information regarding the consequences of behaviors, comparisons with peer norms and health guidelines, tips for behavior change, and reinforcement of healthy choices. A small but noteworthy minority of participants dismissed the peer norms as not real or relevant and national guidelines as not valid or reasonable. When prompted for possible adaptations to the tool, adolescents expressed interest in receiving follow-up information, setting health-related goals, tracking their behaviors over time, and communicating with providers electronically between appointments. Adolescents in this qualitative study desired feedback that validates their healthy behavior choices and supports them as independent decision makers by neutrally presenting health information, facilitating goal setting, and offering ongoing technological supports. ©Garret G Zieve, Laura P Richardson, Katherine Katzman, Heather Spielvogle, Sandy Whitehouse, Carolyn A McCarty. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 20.07.2017.
ERIC Educational Resources Information Center
Riggsby, Dutchie
This paper describes a project at Columbus State University (Columbus, Georgia) to have students in the School of Education develop an electronic resume. A grant proposal was written which requested laptops for the development of electronic portfolios, and funding was received. Student participants were selected and were provided with Macintosh…
Teruya, Alan T [Livermore, CA; Elmer,; John, W [Danville, CA; Palmer, Todd A [State College, PA
2011-03-08
A diagnostic system for characterization of an electron beam or an ion beam includes an electrical conducting disk of refractory material having a circumference, a center, and a Faraday cup assembly positioned to receive the electron beam or ion beam. At least one slit in the disk provides diagnostic characterization of the electron beam or ion beam. The at least one slit is located between the circumference and the center of the disk and includes a radial portion that is in radial alignment with the center and a portion that deviates from radial alignment with the center. The electron beam or ion beam is directed onto the disk and translated to the at least one slit wherein the electron beam or ion beam enters the at least one slit for providing diagnostic characterization of the electron beam or ion beam.
MATLAB/Simulink Pulse-Echo Ultrasound System Simulator Based on Experimentally Validated Models.
Kim, Taehoon; Shin, Sangmin; Lee, Hyongmin; Lee, Hyunsook; Kim, Heewon; Shin, Eunhee; Kim, Suhwan
2016-02-01
A flexible clinical ultrasound system must operate with different transducers, which have characteristic impulse responses and widely varying impedances. The impulse response determines the shape of the high-voltage pulse that is transmitted and the specifications of the front-end electronics that receive the echo; the impedance determines the specification of the matching network through which the transducer is connected. System-level optimization of these subsystems requires accurate modeling of pulse-echo (two-way) response, which in turn demands a unified simulation of the ultrasonics and electronics. In this paper, this is realized by combining MATLAB/Simulink models of the high-voltage transmitter, the transmission interface, the acoustic subsystem which includes wave propagation and reflection, the receiving interface, and the front-end receiver. To demonstrate the effectiveness of our simulator, the models are experimentally validated by comparing the simulation results with the measured data from a commercial ultrasound system. This simulator could be used to quickly provide system-level feedback for an optimized tuning of electronic design parameters.
Information on Receiving Contract and Commercial Payments
Provides links to payment instructions and financial forms and reports for vendors and grant recipients. Billing tips, instructions for submitting invoices electronically or by email, including submitting simplified acquisition payments (SAPs).
NASA Technical Reports Server (NTRS)
Sun, Xiaoli; Davidson, Frederic M.
1990-01-01
A newly developed 220 Mbps free-space 4-ary pulse position modulation (PPM) direct detection optical communication system is described. High speed GaAs integrated circuits were used to construct the PPM encoder and receiver electronic circuits. Both PPM slot and word timing recovery were provided in the PPM receiver. The optical transmitter consisted of an AlGaAs laser diode (Mitsubishi ML5702A, lambda=821nm) and a high speed driver unit. The photodetector consisted of a silicon avalanche photodiode (APD) (RCA30902S) preceded by an optical interference filter (delta lambda=10nm). Preliminary tests showed that the self-synchronized PPM receiver could achieve a receiver bit error rate of less than 10(exp -6) at 25 nW average received optical signal power or 360 photons per transmitted information bit. The relatively poor receiver sensitivity was believed to be caused by the insufficient electronic bandwidth of the APD preamplifier and the poor linearity of the preamplifier high frequency response.
Margaryan, Amur [Yerevan, AM; Gynashyan, Karlen [Yerevan, AM; Hashimoto, Osamu [Sendai, JP; Majewski, Stanislaw [Morgantown, WV; Tang, Linguang [Yorktown, VA; Marikyan, Gagik [Yerevan, AM; Marikyan, legal representative, Lia
2012-03-20
A method and apparatus of obtaining a record of repetitive optical or other phenomena having durations in the picosecond range, comprising a circular scan electron tube to receive light pulses and convert them to electron images consisting with fast nanosecond electronic signals, a continuous wave light or other particle pulses, e.g. electron picosecond pulses, and a synchronizing mechanism arranged to synchronize the deflection of the electron image (images) in the tube (tubes) with the repetition rate of the incident pulse train. There is also provided a method and apparatus for digitization of a repetitive and random optical waveform with a bandwidth higher than 10 GHz.
Connecting Biology to Electronics: Molecular Communication via Redox Modality.
Liu, Yi; Li, Jinyang; Tschirhart, Tanya; Terrell, Jessica L; Kim, Eunkyoung; Tsao, Chen-Yu; Kelly, Deanna L; Bentley, William E; Payne, Gregory F
2017-12-01
Biology and electronics are both expert at for accessing, analyzing, and responding to information. Biology uses ions, small molecules, and macromolecules to receive, analyze, store, and transmit information, whereas electronic devices receive input in the form of electromagnetic radiation, process the information using electrons, and then transmit output as electromagnetic waves. Generating the capabilities to connect biology-electronic modalities offers exciting opportunities to shape the future of biosensors, point-of-care medicine, and wearable/implantable devices. Redox reactions offer unique opportunities for bio-device communication that spans the molecular modalities of biology and electrical modality of devices. Here, an approach to search for redox information through an interactive electrochemical probing that is analogous to sonar is adopted. The capabilities of this approach to access global chemical information as well as information of specific redox-active chemical entities are illustrated using recent examples. An example of the use of synthetic biology to recognize external molecular information, process this information through intracellular signal transduction pathways, and generate output responses that can be detected by electrical modalities is also provided. Finally, exciting results in the use of redox reactions to actuate biology are provided to illustrate that synthetic biology offers the potential to guide biological response through electrical cues. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Dixon, Brian E; Colvard, Cyril; Tierney, William M
2014-06-24
Objective: To support collation of data for disability determination, we sought to accurately identify facilities where care was delivered across multiple, independent hospitals and clinics. Methods: Data from various institutions' electronic health records were merged and delivered as continuity of care documents to the United States Social Security Administration (SSA). Results: Electronic records for nearly 8000 disability claimants were exchanged with SSA. Due to the lack of standard nomenclature for identifying the facilities in which patients received the care documented in the electronic records, SSA could not match the information received with information provided by disability claimants. Facility identifiers were generated arbitrarily by health care systems and therefore could not be mapped to the existing international standards. Discussion: We propose strategies for improving facility identification in electronic health records to support improved tracking of a patient's care between providers to better serve clinical care delivery, disability determination, health reform and meaningful use. Conclusion: Accurately identifying the facilities where health care is delivered to patients is important to a number of major health reform and improvement efforts underway in many nations. A standardized nomenclature for identifying health care facilities is needed to improve tracking of care and linking of electronic health records.
Garden-Robinson, Julie; Eighmy, Myron A; Lyonga, Agnes Ngale
2010-12-01
The purpose of this study was to determine the types of unfamiliar foods international students in the U.S. encounter and to assess food safety information that international students would like to receive for mitigating risks associated with handling and preparing unfamiliar foods. The study identified preferred instructional delivery methods and media for receiving food safety training or information. An electronic group method was used for this study. The electronic group method was chosen to maximize group efficiency by allowing participants to share ideas simultaneously and anonymously with minimal use of time and resources.Types of different (unfamiliar) foods were grouped into major categories. Fast and ready-to-eat foods, and processed and frozen foods constituted a major change for some international students, who were accustomed to homemade and fresh foods in their countries. Participants were interested in receiving information about how to safely handle and prepare unfamiliar foods in their new environment. Preferred methods for receiving food safety information included written materials, online publications, presentations, and materials provided during student orientation. Food packages, websites, and television programs were other preferred methods of receiving food safety information. Copyright © 2010 Elsevier Ltd. All rights reserved.
Schauer, Stephanie L; Maerz, Thomas R; Verdon, Matthew J; Hopfensperger, Daniel J; Davis, Jeffrey P
2014-06-01
The Wisconsin Immunization Registry is a confidential, web-based system used since 1999 as a centralized repository of immunization information for Wisconsin residents. Provide evidence based on Registry experiences with electronic data exchange, comparing the benefits and drawbacks of using the Health Level 7 standard, including the option for real time data exchange vs the flat file method. For data regarding vaccinations received by children aged 4 months through 6 years with Wisconsin addresses that were submitted to the Registry during 2010 and 2011, data timeliness (days from vaccine administration to date information was received) and completeness (percentage of records received that include core data elements for electronic storage) were compared by file submission method. Data submitted using Health Level 7 were substantially more timely than data submitted using the flat file method. Additionally, data submitted using Health Level 7 were substantially more complete for each of the core elements compared to flat file submission. Health care organizations that submit electronic data to immunization information systems should be aware that the technical decision to use the Health Level 7 format, particularly if real-time data exchange is employed, can result in more timely and accurate data. This will assist clinicians in adhering to the Advisory Committee on Immunization Practices schedule and reducing over-immunization.
Self-seeded injection-locked FEL amplifer
Sheffield, Richard L.
1999-01-01
A self-seeded free electron laser (FEL) provides a high gain and extraction efficiency for the emitted light. An accelerator outputs a beam of electron pulses to a permanent magnet wiggler having an input end for receiving the electron pulses and an output end for outputting light and the electron pulses. An optical feedback loop collects low power light in a small signal gain regime at the output end of said wiggler and returns the low power light to the input end of the wiggler while outputting high power light in a high signal gain regime.
Integrated control system and method
Wang, Paul Sai Keat; Baldwin, Darryl; Kim, Myoungjin
2013-10-29
An integrated control system for use with an engine connected to a generator providing electrical power to a switchgear is disclosed. The engine receives gas produced by a gasifier. The control system includes an electronic controller associated with the gasifier, engine, generator, and switchgear. A gas flow sensor monitors a gas flow from the gasifier to the engine through an engine gas control valve and provides a gas flow signal to the electronic controller. A gas oversupply sensor monitors a gas oversupply from the gasifier and provides an oversupply signal indicative of gas not provided to the engine. A power output sensor monitors a power output of the switchgear and provide a power output signal. The electronic controller changes gas production of the gasifier and the power output rating of the switchgear based on the gas flow signal, the oversupply signal, and the power output signal.
Vehicle drive module having improved EMI shielding
Beihoff, Bruce C.; Kehl, Dennis L.; Gettelfinger, Lee A.; Kaishian, Steven C.; Phillips, Mark G.; Radosevich, Lawrence D.
2006-11-28
EMI shielding in an electric vehicle drive is provided for power electronics circuits and the like via a direct-mount reference plane support and shielding structure. The thermal support may receive one or more power electronic circuits. The support may aid in removing heat from the circuits through fluid circulating through the support. The support forms a shield from both external EMI/RFI and from interference generated by operation of the power electronic circuits. Features may be provided to permit and enhance connection of the circuitry to external circuitry, such as improved terminal configurations. Modular units may be assembled that may be coupled to electronic circuitry via plug-in arrangements or through interface with a backplane or similar mounting and interconnecting structures.
2006-08-08
As required by the Medicare Prescription Drug, Improvement, and Modernization Act of 2003 (MMA), Public Law 108-173, this final rule establishes a new safe harbor under the Federal anti-kickback statute for certain arrangements involving the provision of electronic prescribing technology. Specifically, the safe harbor would protect certain arrangements involving hospitals, group practices, and prescription drug plan (PDP) sponsors and Medicare Advantage (MA) organizations that provide to specified recipients certain nonmonetary remuneration in the form of hardware, software, or information technology and training services necessary and used solely to receive and transmit electronic prescription information. In addition, in accordance with section 1128B(b)(3)(E) of the Social Security Act (the Act), this final rule creates a separate new safe harbor for certain arrangements involving the provision of nonmonetary remuneration in the form of electronic health records software or information technology and training services necessary and used predominantly to create, maintain, transmit, or receive electronic health records.
Ionospheric corrections to precise time transfer using GPS
NASA Technical Reports Server (NTRS)
Snow, Robert W.; Osborne, Allen W., III; Klobuchar, John A.; Doherty, Patricia H.
1994-01-01
The free electrons in the earth's ionosphere can retard the time of reception of GPS signals received at a ground station, compared to their time in free space, by many tens of nanoseconds, thus limiting the accuracy of time transfer by GPS. The amount of the ionospheric time delay is proportional to the total number of electrons encountered by the wave on its path from each GPS satellite to a receiver. This integrated number of electrons is called Total Electron Content, or TEC. Dual frequency GPS receivers designed by Allen Osborne Associates, Inc. (AOA) directly measure both the ionospheric differential group delay and the differential carrier phase advance for the two GPS frequencies and derive from this the TEC between the receiver and each GPS satellite in track. The group delay information is mainly used to provide an absolute calibration to the relative differential carrier phase, which is an extremely precise measure of relative TEC. The AOA Mini-Rogue ICS-4Z and the AOA TurboRogue ICS-4000Z receivers normally operate using the GPS P code, when available, and switch to cross-correlation signal processing when the GPS satellites are in the Anti-Spoofing (A-S) mode and the P code is encrypted. An AOA ICS-Z receiver has been operated continuously for over a year at Hanscom AFB, MA to determine the statistics of the variability of the TEC parameter using signals from up to four different directions simultaneously. The 4-channel ICS-4Z and the 8-channel ICS-4000Z, have proven capabilities to make precise, well calibrated, measurements of the ionosphere in several directions simultaneously. In addition to providing ionospheric corrections for precise time transfer via satellite, this dual frequency design allows full code and automatic codeless operation of both the differential group delay and differential carrier phase for numerous ionospheric experiments being conducted. Statistical results of the data collected from the ICS-4Z during the initial year of ionospheric time delay in the northeastern U.S., and initial results with the ICS-4000Z, will be presented.
The economics of electronic journals.
Budd, K W
2000-01-01
High print journal subscription costs, access to desktop publishing software, and awareness of Internet capability are among several reasons that interest in the electronic publishing of scholarly journals is increasing rapidly. The economic considerations of electronic publishing are not as familiar, however, although the fingertip accessibility of electronic journals, and in some cases, the lack of subscription charges gives the impression that electronic journal publishing is a much less costly means of publishing. Such an impression receives qualified confirmation in this article as an overview of the costs of scholarly publishing is provided, and the costs of print and electronic journals are compared. Also addressed are ways to recover costs of publishing electronic journals, and predictions for the future of such journals.
16 CFR 680.26 - Delivery of opt-out notices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 680.26 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT AFFILIATE MARKETING... reasonably be expected to receive actual notice if the affiliate providing the notice: (1) Hand-delivers a... electronic disclosures by e-mail from the affiliate providing the notice; or (4) Posts the notice on the...
16 CFR 680.26 - Delivery of opt-out notices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 680.26 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT AFFILIATE MARKETING... reasonably be expected to receive actual notice if the affiliate providing the notice: (1) Hand-delivers a... electronic disclosures by e-mail from the affiliate providing the notice; or (4) Posts the notice on the...
16 CFR 680.26 - Delivery of opt-out notices.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 680.26 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT AFFILIATE MARKETING... reasonably be expected to receive actual notice if the affiliate providing the notice: (1) Hand-delivers a... electronic disclosures by e-mail from the affiliate providing the notice; or (4) Posts the notice on the...
16 CFR 680.26 - Delivery of opt-out notices.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 680.26 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT AFFILIATE MARKETING... reasonably be expected to receive actual notice if the affiliate providing the notice: (1) Hand-delivers a... electronic disclosures by e-mail from the affiliate providing the notice; or (4) Posts the notice on the...
Digital Audio Radio Broadcast Systems Laboratory Testing Nearly Complete
NASA Technical Reports Server (NTRS)
2005-01-01
Radio history continues to be made at the NASA Lewis Research Center with the completion of phase one of the digital audio radio (DAR) testing conducted by the Consumer Electronics Group of the Electronic Industries Association. This satellite, satellite/terrestrial, and terrestrial digital technology will open up new audio broadcasting opportunities both domestically and worldwide. It will significantly improve the current quality of amplitude-modulated/frequency-modulated (AM/FM) radio with a new digitally modulated radio signal and will introduce true compact-disc-quality (CD-quality) sound for the first time. Lewis is hosting the laboratory testing of seven proposed digital audio radio systems and modes. Two of the proposed systems operate in two modes each, making a total of nine systems being tested. The nine systems are divided into the following types of transmission: in-band on-channel (IBOC), in-band adjacent-channel (IBAC), and new bands. The laboratory testing was conducted by the Consumer Electronics Group of the Electronic Industries Association. Subjective assessments of the audio recordings for each of the nine systems was conducted by the Communications Research Center in Ottawa, Canada, under contract to the Electronic Industries Association. The Communications Research Center has the only CCIR-qualified (Consultative Committee for International Radio) audio testing facility in North America. The main goals of the U.S. testing process are to (1) provide technical data to the Federal Communication Commission (FCC) so that it can establish a standard for digital audio receivers and transmitters and (2) provide the receiver and transmitter industries with the proper standards upon which to build their equipment. In addition, the data will be forwarded to the International Telecommunications Union to help in the establishment of international standards for digital audio receivers and transmitters, thus allowing U.S. manufacturers to compete in the world market.
16 CFR 803.10 - Running of time.
Code of Federal Regulations, 2011 CFR
2011-01-01
... effected to the server maintained by the FTC for the purpose of receiving electronic filings. (iii) For... server or the date on which delivery of the attachments is effected to the designated offices as provided...
7 CFR 400.209 - Electronic transmission and receiving system.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 6 2012-01-01 2012-01-01 false Electronic transmission and receiving system. 400.209... Contract-Standards for Approval § 400.209 Electronic transmission and receiving system. Any Contractor...; (b) Maintain an electronic system which must be tested and approved by the Corporation; (c) Maintain...
7 CFR 400.209 - Electronic transmission and receiving system.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 6 2013-01-01 2013-01-01 false Electronic transmission and receiving system. 400.209... Contract-Standards for Approval § 400.209 Electronic transmission and receiving system. Any Contractor...; (b) Maintain an electronic system which must be tested and approved by the Corporation; (c) Maintain...
7 CFR 400.209 - Electronic transmission and receiving system.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 6 2011-01-01 2011-01-01 false Electronic transmission and receiving system. 400.209... Contract-Standards for Approval § 400.209 Electronic transmission and receiving system. Any Contractor...; (b) Maintain an electronic system which must be tested and approved by the Corporation; (c) Maintain...
7 CFR 400.209 - Electronic transmission and receiving system.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 6 2010-01-01 2010-01-01 false Electronic transmission and receiving system. 400.209... Contract-Standards for Approval § 400.209 Electronic transmission and receiving system. Any Contractor...; (b) Maintain an electronic system which must be tested and approved by the Corporation; (c) Maintain...
NASA Astrophysics Data System (ADS)
Gunn, Stanley V.
1998-01-01
The term, ``power beaming'', creates an image of a beam of focused electromagnetic radiation, possessing good transmission characteristics and sufficient intensity to effect the delivery of meaningful amounts of power to a designated receiver. High power, free-electron lasers are well suited for long range transmission of their laser beam to designated space receivers because their selective near infrared wave length can be adjusted to match the absorption characteristics of the receiver's photo voltaic cells. The typical system envisioned is comprised of a 200 kw free electron laser, possessing an over-all efficiency of 10%, and an optical beam director system equipped with appropriate tracking and atmospheric compensation capabilities. Such an installation located at four to five appropriate locations around the earth could provide remarkable benefits to the projected power demands for transfer and maneuvering into orbit and for operating future fleets of satellites.
Photoelectrochemically driven self-assembly method
Nielson, Gregory N.; Okandan, Murat
2017-01-17
Various technologies described herein pertain to assembling electronic devices into a microsystem. The electronic devices are disposed in a solution. Light can be applied to the electronic devices in the solution. The electronic devices can generate currents responsive to the light applied to the electronic devices in the solution, and the currents can cause electrochemical reactions that functionalize regions on surfaces of the electronic devices. Additionally or alternatively, the light applied to the electronic devices in the solution can cause the electronic devices to generate electric fields, which can orient the electronic devices and/or induce movement of the electronic devices with respect to a receiving substrate. Further, electrodes on a receiving substrate can be biased to attract and form connections with the electronic devices having the functionalized regions on the surfaces. The microsystem can include the receiving substrate and the electronic devices connected to the receiving substrate.
More About Lens Antenna For Mobile/Satellite Communication
NASA Technical Reports Server (NTRS)
Rahmat-Samii, Y.; Bodnar, D. G.; Rainer, B. K.
1990-01-01
Report presents additional details of design of proposed phased-array antenna described in "Lens Antenna for Mobile/Satellite Communication" (NPO-16948). Intended to be compact and to lie flat on top of vehicle on ground. Transmits and receives circularly polarized radiation in frequency ranges of 821 to 825 MHz and 860 to 870 MHz. Transmitting and receiving beams electronically steerable to any of 48 evenly spaced directions to provide complete azimuth coverage, and would be fixed, but wide, in elevation, to provide coverage at elevation angles from 20 degrees to 60 degrees.
Medical providers' dental information needs: a baseline survey.
Acharya, Amit; Mahnke, Andrea; Chyou, Po-Huang; Rottscheit, Carla; Starren, Justin B
2011-01-01
Articulation of medical and dental practices has been strongly called for based on the many oral-systemic connections. With the rapid development and adoption of electronic health records, the feasibility of integrating medical and dental patient data should be strongly considered. The objective of this study was to develop an initial understanding of the medical providers' core dental information needs and opinion of integrated medical-dental electronic health record (iEHR) environment in their workflow. This was achieved by administering a 13 question survey to a group of 1,197 medical care providers employed by Marshfield Clinic in Wisconsin, United States. The survey received a response rate of 35%. The responses were analyzed based on provider 'Role' and 'Specialty'. The majority of the respondents felt the need for patient's dental information to coordinate or provide effective medical care. An integrated electronic health record environment could facilitate this holistic patient care approach.
Adaptive array antenna for satellite cellular and direct broadcast communications
NASA Technical Reports Server (NTRS)
Horton, Charles R.; Abend, Kenneth
1993-01-01
Adaptive phased-array antennas provide cost-effective implementation of large, light weight apertures with high directivity and precise beamshape control. Adaptive self-calibration allows for relaxation of all mechanical tolerances across the aperture and electrical component tolerances, providing high performance with a low-cost, lightweight array, even in the presence of large physical distortions. Beam-shape is programmable and adaptable to changes in technical and operational requirements. Adaptive digital beam-forming eliminates uplink contention by allowing a single electronically steerable antenna to service a large number of receivers with beams which adaptively focus on one source while eliminating interference from others. A large, adaptively calibrated and fully programmable aperture can also provide precise beam shape control for power-efficient direct broadcast from space. Advanced adaptive digital beamforming technologies are described for: (1) electronic compensation of aperture distortion, (2) multiple receiver adaptive space-time processing, and (3) downlink beam-shape control. Cost considerations for space-based array applications are also discussed.
Power converter having improved fluid cooling
Meyer, Andreas A.; Radosevich, Lawrence D.; Beihoff, Bruce C.; Kehl, Dennis L.; Kannenberg, Daniel G.
2007-03-06
A thermal support may receive one or more power electronic circuits. The support may aid in removing heat from the circuits through fluid circulating through the support, which may be controlled in a closed-loop manner. Interfacing between circuits, circuit mounting structure, and the support provide for greatly enhanced cooling. The support may form a shield from both external EMI/RFI and from interference generated by operation of the power electronic circuits. Features may be provided to permit and enhance connection of the circuitry to external circuitry, such as improved terminal configurations. Modular units may be assembled that may be coupled to electronic circuitry via plug-in arrangements or through interface with a backplane or similar mounting and interconnecting structures.
48 CFR 232.7004 - Contract clause.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Section 232.7004 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7004 Contract clause. (a) Except as provided in 232...
48 CFR 232.7004 - Contract clauses.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Section 232.7004 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7004 Contract clauses. (a) Except as provided in 232...
48 CFR 232.7004 - Contract clause.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Section 232.7004 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7004 Contract clause. (a) Except as provided in 232...
de Jonge, Niels [Oak Ridge, TN
2010-08-17
A confocal scanning transmission electron microscope which includes an electron illumination device providing an incident electron beam propagating in a direction defining a propagation axis, and a precision specimen scanning stage positioned along the propagation axis and movable in at least one direction transverse to the propagation axis. The precision specimen scanning stage is configured for positioning a specimen relative to the incident electron beam. A projector lens receives a transmitted electron beam transmitted through at least part of the specimen and focuses this transmitted beam onto an image plane, where the transmitted beam results from the specimen being illuminated by the incident electron beam. A detection system is placed approximately in the image plane.
High-performance parallel interface to synchronous optical network gateway
St. John, Wallace B.; DuBois, David H.
1996-01-01
A system of sending and receiving gateways interconnects high speed data interfaces, e.g., HIPPI interfaces, through fiber optic links, e.g., a SONET network. An electronic stripe distributor distributes bytes of data from a first interface at the sending gateway onto parallel fiber optics of the fiber optic link to form transmitted data. An electronic stripe collector receives the transmitted data on the parallel fiber optics and reforms the data into a format effective for input to a second interface at the receiving gateway. Preferably, an error correcting syndrome is constructed at the sending gateway and sent with a data frame so that transmission errors can be detected and corrected in a real-time basis. Since the high speed data interface operates faster than any of the fiber optic links the transmission rate must be adapted to match the available number of fiber optic links so the sending and receiving gateways monitor the availability of fiber links and adjust the data throughput accordingly. In another aspect, the receiving gateway must have sufficient available buffer capacity to accept an incoming data frame. A credit-based flow control system provides for continuously updating the sending gateway on the available buffer capacity at the receiving gateway.
The First Results About Earthquake Study with FORMOSAT-3/COSMIC
NASA Astrophysics Data System (ADS)
Liu, J. Y.; Oyama, K.; Jhuang, H. K.; Istep, M.; Hsiao, C. C.; Wang, Y. H.
2007-12-01
To improve the global weather prediction and space weather monitoring, six microsatellites termed the Formosa Satellite 3 - Constellation Observing System for Meteorology, Ionosphere, and Climate (FORMOSAT-3/COSMIC) were launched into a circular low-Earth orbit (LEO) from Vandenberg Air Force Base, California, at 0140 UTC on 15 April 2006. Each microsatellite of the joint Taiwan-US satellite constellation mission has a GPS occultation experiment (GOX) payload to operate the atmospheric and ionospheric radio occultation, a tiny ionospheric photometer (TIP) to observe the nighttime ionospheric airglow OI 135.6 nm emission, and a tri-band beacon (TBB) to tomographically estimate fine structures of ionospheric electron density on the satellite-to-receiver plane. While the GOX daily observes about 2500 vertical electron density profiles up to the satellite altitude, the TIP provides accurate horizontal gradients of nighttime electron density. In this study, anomalies in the ionospheric electron density structure and dynamics concurrently observed by FORMOSAT-3/COSMIC and co-located ground- based GPS receivers before recent large earthquakes are presented and discussed.
Advancements in the U.S. Army Corps of Engineers Hydrographic Survey Capabilities: The SHOALS System
2016-05-12
forward direction of the aircraft. The scanner uses feedback from an inertial reference unit , rigidly mounted to the TRS, that measures aircraft roll ...LTN-90 inertial reference unit provides aircraft attitude, including roll , pitch, and heading and vertical accelerations. The unit supports four...Figure 3 The transceiver subsystem. From left to right, receiver optics, receiver electronics, telescope, scanner, and inertial reference unit . The
Do, Thanh Nho; Visell, Yon
2017-05-11
Stretchable and flexible multifunctional electronic components, including sensors and actuators, have received increasing attention in robotics, electronics, wearable, and healthcare applications. Despite advances, it has remained challenging to design analogs of many electronic components to be highly stretchable, to be efficient to fabricate, and to provide control over electronic performance. Here, we describe highly elastic sensors and interconnects formed from thin, twisted conductive microtubules. These devices consist of twisted assemblies of thin, highly stretchable (>400%) elastomer tubules filled with liquid conductor (eutectic gallium indium, EGaIn), and fabricated using a simple roller coating process. As we demonstrate, these devices can operate as multimodal sensors for strain, rotation, contact force, or contact location. We also show that, through twisting, it is possible to control their mechanical performance and electronic sensitivity. In extensive experiments, we have evaluated the capabilities of these devices, and have prototyped an array of applications in several domains of stretchable and wearable electronics. These devices provide a novel, low cost solution for high performance stretchable electronics with broad applications in industry, healthcare, and consumer electronics, to emerging product categories of high potential economic and societal significance.
GPS receiver CODE bias estimation: A comparison of two methods
NASA Astrophysics Data System (ADS)
McCaffrey, Anthony M.; Jayachandran, P. T.; Themens, D. R.; Langley, R. B.
2017-04-01
The Global Positioning System (GPS) is a valuable tool in the measurement and monitoring of ionospheric total electron content (TEC). To obtain accurate GPS-derived TEC, satellite and receiver hardware biases, known as differential code biases (DCBs), must be estimated and removed. The Center for Orbit Determination in Europe (CODE) provides monthly averages of receiver DCBs for a significant number of stations in the International Global Navigation Satellite Systems Service (IGS) network. A comparison of the monthly receiver DCBs provided by CODE with DCBs estimated using the minimization of standard deviations (MSD) method on both daily and monthly time intervals, is presented. Calibrated TEC obtained using CODE-derived DCBs, is accurate to within 0.74 TEC units (TECU) in differenced slant TEC (sTEC), while calibrated sTEC using MSD-derived DCBs results in an accuracy of 1.48 TECU.
NASA Astrophysics Data System (ADS)
Issautier, Karine; Ongala-Edoumou, Samuel; Moncuquet, Michel
2016-04-01
The quasi-thermal noise (QTN) method consists in measuring the electrostatic fluctuations produced by the thermal motion of the ambient particles. This noise is detected with a sensitive wave receiver and measured at the terminal of a passive electric antenna, which is immersed in a stable plasma. The analysis of the so-called QTN provides in situ measurements, mainly the total electron density, with a good accuracy, and thermal temperature in a large number of space media. We create a preliminary electron database to analyse the anti-correlation between electron density and temperature deduced from WIND perigees in the Earth's plasmasphere. We analyse the radio power spectra measured by the Thermal Noise Receiver (TNR), using the 100-m long dipole antenna, onboard WIND spacecraft. We develop a systematic routine to determine the electron density, core and halo temperature and the magnitude of the magnetic field based on QTN in Bernstein modes. Indeed, the spectra are weakly banded between gyroharmonics below the upper hybrid frequency, from which we derive the local electron density. From the gyrofrequency determination, we obtain an independent measure of the magnetic field magnitude, which is in close agreement with the onboard magnetometer.
48 CFR 232.7004 - Contract clause.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Section 232.7004 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7004 Contract clause. Except as provided in 232.7002(a...
48 CFR 232.7004 - Contract clause.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Section 232.7004 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Electronic Submission and Processing of Payment Requests and Receiving Reports 232.7004 Contract clause. Except as provided in 232.7002(a...
Photonic-powered cable assembly
Sanderson, Stephen N.; Appel, Titus James; Wrye, IV, Walter C.
2013-01-22
A photonic-cable assembly includes a power source cable connector ("PSCC") coupled to a power receive cable connector ("PRCC") via a fiber cable. The PSCC electrically connects to a first electronic device and houses a photonic power source and an optical data transmitter. The fiber cable includes an optical transmit data path coupled to the optical data transmitter, an optical power path coupled to the photonic power source, and an optical feedback path coupled to provide feedback control to the photonic power source. The PRCC electrically connects to a second electronic device and houses an optical data receiver coupled to the optical transmit data path, a feedback controller coupled to the optical feedback path to control the photonic power source, and a photonic power converter coupled to the optical power path to convert photonic energy received over the optical power path to electrical energy to power components of the PRCC.
Photonic-powered cable assembly
Sanderson, Stephen N; Appel, Titus James; Wrye, IV, Walter C
2014-06-24
A photonic-cable assembly includes a power source cable connector ("PSCC") coupled to a power receive cable connector ("PRCC") via a fiber cable. The PSCC electrically connects to a first electronic device and houses a photonic power source and an optical data transmitter. The fiber cable includes an optical transmit data path coupled to the optical data transmitter, an optical power path coupled to the photonic power source, and an optical feedback path coupled to provide feedback control to the photonic power source. The PRCC electrically connects to a second electronic device and houses an optical data receiver coupled to the optical transmit data path, a feedback controller coupled to the optical feedback path to control the photonic power source, and a photonic power converter coupled to the optical power path to convert photonic energy received over the optical power path to electrical energy to power components of the PRCC.
All-Dielectric Photonic-Assisted Radio Front-End Technology
NASA Astrophysics Data System (ADS)
Ayazi, Hossein Ali
The threats to civil society posed by high-power electromagnetic weapons are viewed as a grim but real possibility in the world after 11 September 2001. These weapons produce a power surge capable of destroying or damaging sensitive circuitry in electronic systems. Unfortunately, the trend towards circuits with smaller sizes and voltages renders modern electronics highly susceptible to such damage. Radiofrequency communication systems are particularly vulnerable, because the antenna provides a direct port of entry for electromagnetic radiation. In this work, we present a novel type of radiofrequency receiver front end featuring a complete absence of electronic circuitry and metal interconnects, the traditional 'soft spots' of a conventional radiofrequency receiver. The device exploits a dielectric resonator antenna to capture and deliver the radiofrequency signal onto a whispering-gallery mode electro-optic field sensor. The dielectric approach has an added benefit in that it reduces the physical size of the front end, an important benefit in mobile applications.
Opto-electronic oscillators having optical resonators
NASA Technical Reports Server (NTRS)
Yao, Xiaotian Steve (Inventor); Maleki, Lutfollah (Inventor); Ilchenko, Vladimir (Inventor)
2003-01-01
Systems and techniques of incorporating an optical resonator in an optical part of a feedback loop in opto-electronic oscillators. This optical resonator provides a sufficiently long energy storage time and hence to produce an oscillation of a narrow linewidth and low phase noise. Certain mode matching conditions are required. For example, the mode spacing of the optical resonator is equal to one mode spacing, or a multiplicity of the mode spacing, of an opto-electronic feedback loop that receives a modulated optical signal and to produce an electrical oscillating signal.
Hulse, Nathan C; Long, Jie; Xu, Xiaomin; Tao, Cui
2014-01-01
Infobuttons have proven to be an increasingly important resource in providing a standardized approach to integrating useful educational materials at the point of care in electronic health records (EHRs). They provide a simple, uniform pathway for both patients and providers to receive pertinent education materials in a quick fashion from within EHRs and Personalized Health Records (PHRs). In recent years, the international standards organization Health Level Seven has balloted and approved a standards-based pathway for requesting and receiving data for infobuttons, simplifying some of the barriers for their adoption in electronic medical records and amongst content providers. Local content, developed by the hosting organization themselves, still needs to be indexed and annotated with appropriate metadata and terminologies in order to be fully accessible via the infobutton. In this manuscript we present an approach for automating the annotation of internally-developed patient education sheets with standardized terminologies and compare and contrast the approach with manual approaches used previously. We anticipate that a combination of system-generated and human reviewed annotations will provide the most comprehensive and effective indexing strategy, thereby allowing best access to internally-created content via the infobutton.
Autonomous omnidirectional spacecraft antenna system
NASA Technical Reports Server (NTRS)
Taylor, T. H.
1983-01-01
The development of a low gain Electronically Switchable Spherical Array Antenna is discussed. This antenna provides roughly 7 dBic gain for receive/transmit operation between user satellites and the Tracking and Data Relay Satellite System. When used as a pair, the antenna provides spherical coverage. The antenna was tested in its primary operating modes: directed beam, retrodirective, and Omnidirectional.
Compact vehicle drive module having improved thermal control
Meyer, Andreas A.; Radosevich, Lawrence D.; Beihoff, Bruce C.; Kehl, Dennis L.; Kannenberg, Daniel G.
2006-01-03
An electric vehicle drive includes a thermal support may receive one or more power electronic circuits. The support may aid in removing heat from the circuits through fluid circulating through the support, which may be controlled in a closed-loop manner. Interfacing between circuits, circuit mounting structure, and the support provide for greatly enhanced cooling. The support may form a shield from both external EMI/RFI and from interference generated by operation of the power electronic circuits. Features may be provided to permit and enhance connection of the circuitry to external circuitry, such as improved terminal configurations. Modular units may be assembled that may be coupled to electronic circuitry via plug-in arrangements or through interface with a backplane or similar mounting and interconnecting structures.
Extremely-efficient, miniaturized, long-lived alpha-voltaic power source using liquid gallium
NASA Technical Reports Server (NTRS)
Snyder, G. Jeffrey (Inventor); Patel, Jagdishbhai (Inventor); Fleurial, Jean-Pierre (Inventor)
2004-01-01
A power source converts .alpha.-particle energy to electricity for use in electrical systems. Liquid gallium or other liquid medium is subjected to .alpha.-particle emissions. Electrons are freed by collision from neutral gallium atoms to provide gallium ions. The electrons migrate to a cathode while the gallium ions migrate to an anode. A current and/or voltage difference then arises between the cathode and anode because of the work function difference of the cathode and anode. Gallium atoms are regenerated by the receiving of electrons from the anode enabling the generation of additional electrons from additional .alpha.-particle collisions.
Electronic prescribing in pediatrics: toward safer and more effective medication management.
2013-04-01
This policy statement identifies the potential value of electronic prescribing (e-prescribing) systems in improving quality and reducing harm in pediatric health care. On the basis of limited but positive pediatric data and on the basis of federal statutes that provide incentives for the use of e-prescribing systems, the American Academy of Pediatrics recommends the adoption of e-prescribing systems with pediatric functionality. The American Academy of Pediatrics also recommends a set of functions that technology vendors should provide when e-prescribing systems are used in environments in which children receive care.
27 CFR 73.31 - May I submit forms electronically to TTB?
Code of Federal Regulations, 2014 CFR
2014-04-01
...; ELECTRONIC SUBMISSION OF FORMS Electronic Filing of Documents with TTB § 73.31 May I submit forms... above; (c) You submit the electronic form to an electronic document receiving system that we have... submit the form through an electronic document receiving system that TTB has designated for the receipt...
Using GPS Reflections for Satellite Remote Sensing
NASA Technical Reports Server (NTRS)
Mickler, David
2000-01-01
GPS signals that have reflected off of the ocean's surface have shown potential for use in oceanographic and atmospheric studies. The research described here investigates the possible deployment of a GPS reflection receiver onboard a remote sensing satellite in low Earth orbit (LEO). The coverage and resolution characteristics of this receiver are calculated and estimated. This mission analysis examines using reflected GPS signals for several remote sensing missions. These include measurement of the total electron content in the ionosphere, sea surface height, and ocean wind speed and direction. Also discussed is the potential test deployment of such a GPS receiver on the space shuttle. Constellations of satellites are proposed to provide adequate spatial and temporal resolution for the aforementioned remote sensing missions. These results provide a starting point for research into the feasibility of augmenting or replacing existing remote sensing satellites with spaceborne GPS reflection-detecting receivers.
Donohue, SarahMaria; Sesto, Mary E.; Hahn, David L.; Buhr, Kevin A.; Jacobs, Elizabeth A.; Sosman, James M.; Andreason, Molly J.; Wiegmann, Douglas A.; Tevaarwerk, Amye J.
2015-01-01
Purpose: Survivorship care plans for cancer survivors may facilitate provider-to-provider communication. Primary care provider (PCP) perspectives on care plan provision and use are limited, especially when care plans are generated by an electronic health record (EHR) system. We sought to examine PCPs' perspectives regarding EHR-generated care plans. Methods: PCPs (N = 160) who were members of the Wisconsin Research and Education Network listserv received a sample 10-page plan (WREN cohort). PCPs (n = 81) who had or were currently seeing survivors enrolled onto one of our survivorship clinical trials received a copy of the survivor's personalized care plan (University of Wisconsin [UW] cohort). Both cohorts received a survey after reviewing the plan. All plans were generated within an EHR. Results: Forty-six and 26 PCPs participated in the WREN and UW cohorts, respectively. PCPs regarded EHR-generated plans as useful in coordinating care (88%), understanding treatments (94%), understanding treatment adverse effects (89%), and supporting clinical decisions (82%). Few felt using EHR-generated plans would disrupt clinic workflow (14%) or take too much time (11%). Most (89%) preferred receiving the plan via EHR. PCPs reported consistent provision (81%) and standard location in the medical record (89%) as key factors facilitating their use of survivorship care plans. Important facilitators of care plan use included a more abbreviated plan, ideally one to three pages (32%), and/or a plan specifically tailored to PCP use (57%). Conclusion: Plans were viewed as useful for coordinating care and making clinical decisions. However, PCPs desired shorter, clinician-oriented plans, accessible within an EHR and delivered and located in a standardized manner. PMID:25804989
High-performance parallel interface to synchronous optical network gateway
St. John, W.B.; DuBois, D.H.
1996-12-03
Disclosed is a system of sending and receiving gateways interconnects high speed data interfaces, e.g., HIPPI interfaces, through fiber optic links, e.g., a SONET network. An electronic stripe distributor distributes bytes of data from a first interface at the sending gateway onto parallel fiber optics of the fiber optic link to form transmitted data. An electronic stripe collector receives the transmitted data on the parallel fiber optics and reforms the data into a format effective for input to a second interface at the receiving gateway. Preferably, an error correcting syndrome is constructed at the sending gateway and sent with a data frame so that transmission errors can be detected and corrected in a real-time basis. Since the high speed data interface operates faster than any of the fiber optic links the transmission rate must be adapted to match the available number of fiber optic links so the sending and receiving gateways monitor the availability of fiber links and adjust the data throughput accordingly. In another aspect, the receiving gateway must have sufficient available buffer capacity to accept an incoming data frame. A credit-based flow control system provides for continuously updating the sending gateway on the available buffer capacity at the receiving gateway. 7 figs.
Nursing teams: behind the charts.
Bae, Sung-Heui; Farasat, Alireza; Nikolaev, Alex; Seo, Jin Young; Foltz-Ramos, Kelly; Fabry, Donna; Castner, Jessica
2017-07-01
To examine the nature and characteristics of both received and provided mutual support in a social network within an acute care hospital unit. Current evidence regarding the social network in the health care workforce reveals the nature of social ties. Most studies of social network-related support that measured the characteristics of social support used self-reported perception from workers receiving support. There is a gap in studies that focus on back-up behaviour. The evaluation included a social network analysis of a nursing unit employing 54 staff members. A 12 item electronic survey was administered. Descriptive statistics were calculated using the Statistical Package for the Social Sciences. Social network analyses were carried out using ucinet, r 3.2.3 and gephi. Based on the study findings, as providers of mutual support the nursing staff claimed to give their peers more help than these peers gave them credit for. Those who worked overtime provided more mutual support. Mutual support is a key teamwork characteristic, essential to quality and safety in hospital nursing teams that can be evaluated using social network analysis. Because of a discrepancy regarding receiving and providing help, examining both receiver and provider networks is a superior approach to understanding mutual support. © 2017 John Wiley & Sons Ltd.
Riedel, Richard A [Knoxville, TN; Wintenberg, Alan L [Knoxville, TN; Clonts, Lloyd G [Knoxville, TN; Cooper, Ronald G [Oak Ridge, TN
2012-02-14
A preamplifier circuit for processing a signal provided by a radiation detector includes a transimpedance amplifier coupled to receive a current signal from a detector and generate a voltage signal at its output. A second amplification stage has an input coupled to an output of the transimpedance amplifier for providing an amplified voltage signal. Detector electronics include a preamplifier circuit having a first and second transimpedance amplifier coupled to receive a current signal from a first and second location on a detector, respectively, and generate a first and second voltage signal at respective outputs. A second amplification stage has an input coupled to an output of the transimpedance amplifiers for amplifying the first and said second voltage signals to provide first and second amplified voltage signals. A differential output stage is coupled to the second amplification stage for receiving the first and second amplified voltage signals and providing a pair of outputs from each of the first and second amplified voltage signals. Read out circuitry has an input coupled to receive both of the pair of outputs, the read out circuitry having structure for processing each of the pair of outputs, and providing a single digital output having a time-stamp therefrom.
A combined radar-radiometer with variable polarization
NASA Technical Reports Server (NTRS)
Martin, D. P.
1972-01-01
An instrument is described that provides both radar and radiometer data at the same time. The antenna and receiver are time shared for the two sensor functions. The antenna polarization can be electronically scanned at rates up to 5000 changes for both the transmit and receive signal paths. This equipment is to investigate target signatures for remote sensing applications. The function of the equipment is described and the results for observations of asphalt, grass, and gravel surfaces are presented.
Airborne electronically steerable phased array. [steerable antennas - systems analysis
NASA Technical Reports Server (NTRS)
Coats, R.
1975-01-01
Results of a study directed to the design of a lightweight high-gain, spaceborne communications array are presented. The array includes simultaneous transmission and receiving, automatic acquisition and tracking of a signal within a 60-degree cone from the array normal, and provides for independent forming of the transmit and receive beams. Application for this array is the space shuttle, space station, or any of the advanced manned (or unmanned) orbital vehicles. Performance specifications are also given.
Design evaluation: S-band exciters
NASA Technical Reports Server (NTRS)
1974-01-01
A design evaluation study was conducted to produce S-band exciter (SBE) system to provide a highly stable phase or modulated carrier for transmission to spacecraft. The exciter is part of an S-band receiver/exciter/ranging system at Spaceflight Tracking and Data Network (STDN) ground stations. The major features of the system are defined. Circuit diagrams of the electronic components are provided.
Front-end receiver electronics for a matrix transducer for 3-D transesophageal echocardiography.
Yu, Zili; Blaak, Sandra; Chang, Zu-yao; Yao, Jiajian; Bosch, Johan G; Prins, Christian; Lancée, Charles T; de Jong, Nico; Pertijs, Michiel A P; Meijer, Gerard C M
2012-07-01
There is a clear clinical need for creating 3-D images of the heart. One promising technique is the use of transesophageal echocardiography (TEE). To enable 3-D TEE, we are developing a miniature ultrasound probe containing a matrix piezoelectric transducer with more than 2000 elements. Because a gastroscopic tube cannot accommodate the cables needed to connect all transducer elements directly to an imaging system, a major challenge is to locally reduce the number of channels, while maintaining a sufficient signal-to-noise ratio. This can be achieved by using front-end receiver electronics bonded to the transducers to provide appropriate signal conditioning in the tip of the probe. This paper presents the design of such electronics, realizing time-gain compensation (TGC) and micro-beamforming using simple, low-power circuits. Prototypes of TGC amplifiers and micro-beamforming cells have been fabricated in 0.35-μm CMOS technology. These prototype chips have been combined on a printed circuit board (PCB) to form an ultrasound-receiver system capable of reading and combining the signals of three transducer elements. Experimental results show that this design is a suitable candidate for 3-D TEE.
Analysis of rocket beacon transmissions for computerized reconstruction of ionospheric densities
NASA Technical Reports Server (NTRS)
Bernhardt, P. A.; Huba, J. D.; Chaturvedi, P. K.; Fulford, J. A.; Forsyth, P. A.; Anderson, D. N.; Zalesak, S. T.
1993-01-01
Three methods are described to obtain ionospheric electron densities from transionospheric, rocket-beacon TEC data. First, when the line-of-sight from a ground receiver to the rocket beacon is tangent to the flight trajectory, the electron concentration can be obtained by differentiating the TEC with respect to the distance to the rocket. A similar method may be used to obtain the electron-density profile if the layer is horizontally stratified. Second, TEC data obtained during chemical release experiments may be interpreted with the aid of physical models of the disturbed ionosphere to yield spatial maps of the modified regions. Third, computerized tomography (CT) can be used to analyze TEC data obtained along a chain of ground-based receivers aligned along the plane of the rocket trajectory. CT analysis of TEC data is used to reconstruct a 2D image of a simulated equatorial plume. TEC data is computed for a linear chain of nine receivers with adjacent spacings of either 100 or 200 km. The simulation data are analyzed to provide an F region reconstruction on a grid with 15 x 15 km pixels. Ionospheric rocket tomography may also be applied to rocket-assisted measurements of amplitude and phase scintillations and airglow intensities.
2013-09-27
Electronic reporting of laboratory results to public health agencies can improve public health surveillance for reportable diseases and conditions by making reporting more timely and complete. Since 2010, CDC has provided funding to 57 state, local, and territorial health departments through the Epidemiology and Laboratory Capacity for Infectious Diseases cooperative agreement to assist with improving electronic laboratory reporting (ELR) from clinical and public health laboratories to public health agencies. As part of this agreement, CDC and state and large local health departments are collaborating to monitor ELR implementation in the United States by developing data from each jurisdiction regarding total reporting laboratories, laboratories sending ELR by disease category and message format, and the number of ELR laboratory reports compared with the total number of laboratory reports. At the end of July 2013, 54 of the 57 jurisdictions were receiving at least some laboratory reports through ELR, and approximately 62% of 20 million laboratory reports were being received electronically, compared with 54% in 2012. Continued progress will require collaboration between clinical laboratories, laboratory information management system (LIMS) vendors, and public health agencies.
NASA Technical Reports Server (NTRS)
Jones, Robert E.; Kramarchuk, Ihor; Williams, Wallace D.; Pouch, John J.; Gilbert, Percy
1989-01-01
Computer-controlled thermal-wave microscope developed to investigate III-V compound semiconductor devices and materials. Is nondestructive technique providing information on subsurface thermal features of solid samples. Furthermore, because this is subsurface technique, three-dimensional imaging also possible. Microscope uses intensity-modulated electron beam of modified scanning electron microscope to generate thermal waves in sample. Acoustic waves generated by thermal waves received by transducer and processed in computer to form images displayed on video display of microscope or recorded on magnetic disk.
Modular power converter having fluid cooled support
Beihoff, Bruce C.; Radosevich, Lawrence D.; Meyer, Andreas A.; Gollhardt, Neil; Kannenberg, Daniel G.
2005-09-06
A support may receive one or more power electronic circuits. The support may aid in removing heat from the circuits through fluid circulating through the support. The support, in conjunction with other packaging features may form a shield from both external EMI/RFI and from interference generated by operation of the power electronic circuits. Features may be provided to permit and enhance connection of the circuitry to external circuitry, such as improved terminal configurations. Modular units may be assembled that may be coupled to electronic circuitry via plug-in arrangements or through interface with a backplane or similar mounting and interconnecting structures.
Modular power converter having fluid cooled support
Beihoff, Bruce C.; Radosevich, Lawrence D.; Meyer, Andreas A.; Gollhardt, Neil; Kannenberg, Daniel G.
2005-12-06
A support may receive one or more power electronic circuits. The support may aid in removing heat from the circuits through fluid circulating through the support. The support, in conjunction with other packaging features may form a shield from both external EMI/RFI and from interference generated by operation of the power electronic circuits. Features may be provided to permit and enhance connection of the circuitry to external circuitry, such as improved terminal configurations. Modular units may be assembled that may be coupled to electronic circuitry via plug-in arrangements or through interface with a backplane or similar mounting and interconnecting structures.
Compact fluid cooled power converter supporting multiple circuit boards
Radosevich, Lawrence D.; Meyer, Andreas A.; Beihoff, Bruce C.; Kannenberg, Daniel G.
2005-03-08
A support may receive one or more power electronic circuits. The support may aid in removing heat from the circuits through fluid circulating through the support. The support, in conjunction with other packaging features may form a shield from both external EMI/RFI and from interference generated by operation of the power electronic circuits. Features may be provided to permit and enhance connection of the circuitry to external circuitry, such as improved terminal configurations. Modular units may be assembled that may be coupled to electronic circuitry via plug-in arrangements or through interface with a backplane or similar mounting and interconnecting structures.
Narrow field electromagnetic sensor system and method
McEwan, Thomas E.
1996-01-01
A narrow field electromagnetic sensor system and method of sensing a characteristic of an object provide the capability to realize a characteristic of an object such as density, thickness, or presence, for any desired coordinate position on the object. One application is imaging. The sensor can also be used as an obstruction detector or an electronic trip wire with a narrow field without the disadvantages of impaired performance when exposed to dirt, snow, rain, or sunlight. The sensor employs a transmitter for transmitting a sequence of electromagnetic signals in response to a transmit timing signal, a receiver for sampling only the initial direct RF path of the electromagnetic signal while excluding all other electromagnetic signals in response to a receive timing signal, and a signal processor for processing the sampled direct RF path electromagnetic signal and providing an indication of the characteristic of an object. Usually, the electromagnetic signal is a short RF burst and the obstruction must provide a substantially complete eclipse of the direct RF path. By employing time-of-flight techniques, a timing circuit controls the receiver to sample only the initial direct RF path of the electromagnetic signal while not sampling indirect path electromagnetic signals. The sensor system also incorporates circuitry for ultra-wideband spread spectrum operation that reduces interference to and from other RF services while allowing co-location of multiple electronic sensors without the need for frequency assignments.
Narrow field electromagnetic sensor system and method
McEwan, T.E.
1996-11-19
A narrow field electromagnetic sensor system and method of sensing a characteristic of an object provide the capability to realize a characteristic of an object such as density, thickness, or presence, for any desired coordinate position on the object. One application is imaging. The sensor can also be used as an obstruction detector or an electronic trip wire with a narrow field without the disadvantages of impaired performance when exposed to dirt, snow, rain, or sunlight. The sensor employs a transmitter for transmitting a sequence of electromagnetic signals in response to a transmit timing signal, a receiver for sampling only the initial direct RF path of the electromagnetic signal while excluding all other electromagnetic signals in response to a receive timing signal, and a signal processor for processing the sampled direct RF path electromagnetic signal and providing an indication of the characteristic of an object. Usually, the electromagnetic signal is a short RF burst and the obstruction must provide a substantially complete eclipse of the direct RF path. By employing time-of-flight techniques, a timing circuit controls the receiver to sample only the initial direct RF path of the electromagnetic signal while not sampling indirect path electromagnetic signals. The sensor system also incorporates circuitry for ultra-wideband spread spectrum operation that reduces interference to and from other RF services while allowing co-location of multiple electronic sensors without the need for frequency assignments. 12 figs.
Code of Federal Regulations, 2014 CFR
2014-01-01
... person who initiates, to a protected computer, the transmission of a commercial electronic mail message... electronic mail message or other form of Internet-based communication requesting not to receive future... received; and (B) Remains capable of receiving such messages or communications for no less than 30 days...
Code of Federal Regulations, 2013 CFR
2013-01-01
... person who initiates, to a protected computer, the transmission of a commercial electronic mail message... electronic mail message or other form of Internet-based communication requesting not to receive future... received; and (B) Remains capable of receiving such messages or communications for no less than 30 days...
Code of Federal Regulations, 2012 CFR
2012-01-01
... person who initiates, to a protected computer, the transmission of a commercial electronic mail message... electronic mail message or other form of Internet-based communication requesting not to receive future... received; and (B) Remains capable of receiving such messages or communications for no less than 30 days...
Code of Federal Regulations, 2011 CFR
2011-01-01
... person who initiates, to a protected computer, the transmission of a commercial electronic mail message... electronic mail message or other form of Internet-based communication requesting not to receive future... received; and (B) Remains capable of receiving such messages or communications for no less than 30 days...
Evaluation of Rhenium Joining Methods
NASA Technical Reports Server (NTRS)
Reed, Brian D.; Morren, Sybil H.
1995-01-01
Coupons of rhenium-to-Cl03 flat plate joints, formed by explosive and diffusion bonding, were evaluated in a series of shear tests. Shear testing was conducted on as-received, thermally-cycled (100 cycles, from 21 to 1100 C), and thermally-aged (3 and 6 hrs at 1100 C) joint coupons. Shear tests were also conducted on joint coupons with rhenium and/or Cl03 electron beam welded tabs to simulate the joint's incorporation into a structure. Ultimate shear strength was used as a figure of merit to assess the effects of the thermal treatment and the electron beam welding of tabs on the joint coupons. All of the coupons survived thermal testing intact and without any visible degradation. Two different lots of as-received, explosively-bonded joint coupons had ultimate shear strengths of 281 and 310 MPa and 162 and 223 MPa, respectively. As-received, diffusion-bonded coupons had ultimate shear strengths of 199 and 348 MPa. For the most part, the thermally-treated and rhenium weld tab coupons had shear strengths slightly reduced or within the range of the as-received values. Coupons with Cl03 weld tabs experienced a significant reduction in shear strength. The degradation of strength appeared to be the result of a poor heat sink provided during the electron beam welding. The Cl03 base material could not dissipate heat as effectively as rhenium, leading to the formation of a brittle rhenium-niobium intermetallic.
Wireless sensors powered by microbial fuel cells.
Shantaram, Avinash; Beyenal, Haluk; Raajan, Raaja; Veluchamy, Angathevar; Lewandowski, Zbigniew
2005-07-01
Monitoring parameters characterizing water quality, such as temperature, pH, and concentrations of heavy metals in natural waters, is often followed by transmitting the data to remote receivers using telemetry systems. Such systems are commonly powered by batteries, which can be inconvenient at times because batteries have a limited lifetime and must be recharged or replaced periodically to ensure that sufficient energy is available to power the electronics. To avoid these inconveniences, a microbial fuel cell was designed to power electrochemical sensors and small telemetry systems to transmit the data acquired by the sensors to remote receivers. The microbial fuel cell was combined with low-power, high-efficiency electronic circuitry providing a stable power source for wireless data transmission. To generate enough power for the telemetry system, energy produced by the microbial fuel cell was stored in a capacitor and used in short bursts when needed. Since commercial electronic circuits require a minimum 3.3 V input and our cell was able to deliver a maximum of 2.1 V, a DC-DC converter was used to boost the potential. The DC-DC converter powered a transmitter, which gathered the data from the sensor and transmitted it wirelessly to a remote receiver. To demonstrate the utility of the system, temporal variations in temperature were measured, and the data were wirelessly transmitted to a remote receiver.
14 CFR 1260.69 - Electronic funds transfer payment methods.
Code of Federal Regulations, 2010 CFR
2010-01-01
... designate a financial institution or to provide appropriate payee bank account information may delay... information: (1) Name, address, and telegraphic abbreviation of the financial institution receiving payment...) Payee's account number at the financial institution where funds are to be transferred. (4) If the...
Superconductive hot-electron-bolometer mixer receiver for 800-GHz operation
NASA Astrophysics Data System (ADS)
Kawamura, J.; Blundell, R.; Tong, C.-Y. E.; Papa, D. C.; Hunter, T. R.; Paine, S. N.; Patt, F.; Gol'Tsman, G.; Cherednichenko, S.; Voronov, B.; Gershenzon, E.
2000-04-01
In this paper, we describe a superconductive hot-electron-bolometer mixer receiver designed to operate in the partially transmissive 350-μm atmospheric window. The receiver employs an NbN thin-film microbridge as the mixer element, in which the main cooling mechanism of the hot electrons is through electron-phonon interaction. At a local-oscillator frequency of 808 GHz, the measured double-sideband receiver noise temperature is Trx=970 K, across a 1-GHz intermediate-frequency bandwidth centered at 1.8 GHz. We have measured the linearity of the receiver and the amount of local-oscillator power incident on the mixer for optimal operation, which is PLO ≈ 1 microwatt. This receiver was used in making observations as a facility instrument at the Heinrich Hertz Telescope, Mt. Graham, AZ, during the 1998-1999 winter observing season.
Extended write combining using a write continuation hint flag
Chen, Dong; Gara, Alan; Heidelberger, Philip; Ohmacht, Martin; Vranas, Pavlos
2013-06-04
A computing apparatus for reducing the amount of processing in a network computing system which includes a network system device of a receiving node for receiving electronic messages comprising data. The electronic messages are transmitted from a sending node. The network system device determines when more data of a specific electronic message is being transmitted. A memory device stores the electronic message data and communicating with the network system device. A memory subsystem communicates with the memory device. The memory subsystem stores a portion of the electronic message when more data of the specific message will be received, and the buffer combines the portion with later received data and moves the data to the memory device for accessible storage.
Vehicle drive module having improved cooling configuration
Radosevich, Lawrence D.; Meyer, Andreas A.; Kannenberg, Daniel G.; Kaishian, Steven C.; Beihoff, Bruce C.
2007-02-13
An electric vehicle drive includes a thermal support may receive one or more power electronic circuits. The support may aid in removing heat from the circuits through fluid circulating through the support. Power electronic circuits are thermally matched, such as between component layers and between the circuits and the support. The support may form a shield from both external EMI/RFI and from interference generated by operation of the power electronic circuits. Features may be provided to permit and enhance connection of the circuitry to external circuitry, such as improved terminal configurations. Modular units may be assembled that may be coupled to electronic circuitry via plug-in arrangements or through interface with a backplane or similar mounting and interconnecting structures.
Thermally matched fluid cooled power converter
Radosevich, Lawrence D.; Kannenberg, Daniel G.; Kaishian, Steven C.; Beihoff, Bruce C.
2005-06-21
A thermal support may receive one or more power electronic circuits. The support may aid in removing heat from the circuits through fluid circulating through the support. Power electronic circuits are thermally matched, such as between component layers and between the circuits and the support. The support may form a shield from both external EMI/RFI and from interference generated by operation of the power electronic circuits. Features may be provided to permit and enhance connection of the circuitry to external circuitry, such as improved terminal configurations. Modular units may be assembled that may be coupled to electronic circuitry via plug-in arrangements or through interface with a backplane or similar mounting and interconnecting structures.
Use of an electronic patient portal among the chronically ill: an observational study.
Riippa, Iiris; Linna, Miika; Rönkkö, Ilona; Kröger, Virpi
2014-12-08
Electronic patient portals may enhance effective interaction between the patient and the health care provider. To grasp the full potential of patient portals, health care providers need more knowledge on which patient groups prefer electronic services and how patients should be served through this channel. The objective of this study was to assess how chronically ill patients' state of health, comorbidities, and previous care are associated with their adoption and use of a patient portal. A total of 222 chronically ill patients, who were offered access to a patient portal with their health records and secure messaging with care professionals, were included in the study. Differences in the characteristics of non-users, viewers, and interactive users of the patient portal were analyzed before access to the portal. Patients' age, gender, diagnoses, levels of the relevant physiological measurements, health care contacts, and received physiological measurements were collected from the care provider's electronic health record. In addition, patient-reported health and patient activation were assessed by a survey. Despite the broad range of measures used to indicate the patients' state of health, the portal user groups differed only in their recorded diagnosis for hypertension, which was most common in the non-user group. However, there were significant differences in the amount of care received during the year before access to the portal. The non-user group had more nurse visits and more measurements of relevant physiological outcomes than viewers and interactive users. They also had fewer referrals to specialized care during the year before access to the portal than the two other groups. The viewers and the interactive users differed from each other significantly in the number of nurse calls received, the interactive users having more calls than the viewers. No significant differences in age, gender, or patient activation were detected between the user groups. Previous care received by the patient is an important predictor for the use of a patient portal. In a group of patients with a similar disease burden, demand for different types of health services and preferences related to the service channel seem to contribute to the choice to use the patient portal. Further research on patient portal functionalities and their potential to meet patient needs by complementing or substituting for traditional health care services is suggested.
A Guidance Document for Kentucky's Oil and Gas Operations
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
1998-11-10
This technical report is a summary of the progress made for "A Guidance Document for Kentucky's Oil and Gas Operators". During this quarter, the document received continued review and editing in an elec-tronic format to satisfy the United States Department of Energy (DOE). Comments received from oil and gas operators reviewing this document prompted contact to be made with the United States Environmental Protection Agency (USEPA) to develop an addendum section to provide better explanation of USEPA requirements for Class II injection wells in Kentucky.
Rose, Carol Dawson; Johnson, Mallory; Janson, Susan L.
2015-01-01
The HITECH Act signed into law in 2009 requires hospitals to provide patients with electronic access to their health information through an electronic personal health record (ePHR) in order to receive Medicare/Medicaid incentive payments. Little is known about who uses these systems or the impact these systems will have on patient outcomes in HIV care. The health care empowerment model provides rationale for the hypothesis that knowledge from an electronic personal health record can lead to greater patient empowerment resulting in improved outcomes. The objective was to determine the patient characteristics and patient activation, empowerment, satisfaction, knowledge of their CD4, Viral Loads, and antiretroviral medication, and medication adherence outcomes associated with electronic personal health record use in Veterans living with HIV at the San Francisco VA Medical Center. The participants included HIV-Infected Veterans receiving care in a low volume HIV-clinic at the San Francisco VA Medical Center, divided into two groups of users and non-users of electronic personal health records. The research was conducted using in-person surveys either online or on paper and data abstraction from medical records for current anti-retroviral therapy (ART), CD4 count, and plasma HIV-1 viral load. The measures included the Patient Activation Measure, Health Care Empowerment Inventory, ART adherence, provider satisfaction, current CD4 count, current plasma viral load, knowledge of current ART, knowledge of CD4 counts, and knowledge of viral load. In all, 40 participants were recruited. The use of electronic personal health records was associated with significantly higher levels of patient activation and levels of patient satisfaction for getting timely appointments, care, and information. ePHR was also associated with greater proportions of undetectable plasma HIV-1 viral loads, of knowledge of current CD4 count, and of knowledge of current viral load. The two groups differed by race and computer access. There was no difference in the current CD4, provider satisfaction, Health Care Empowerment Inventory score, satisfaction with provider-patient communication, satisfaction with courteous and helpful staff, knowledge of ART, or ART adherence. The use of electronic personal health records is associated with positive clinical and behavioral characteristics. The use of these systems may play a role in improving the health of people with HIV. Larger studies are needed to further evaluate these associations. PMID:25802815
78 FR 26575 - Gross Combination Weight Rating; Definition
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-07
... ``Rules,'' insert ``FMCSA-2012-0156'' in the ``Keyword'' box, and click ``Search.'' When the new screen... side of the screen. Then, in the ``Keyword'' box insert ``FMCSA-2012-0156'' and click ``Search.'' Next... you provide. Anyone is able to search the electronic form of all comments received into any of our...
76 FR 16861 - Availability of Funds and Collection of Checks
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-25
... over the last 5 years. For example, at year-end 2005, the Reserve Banks received about 4 percent of... returned items electronically have decreased substantially. For example, the Reserve Banks now provide... comment on the desirability of these and other alternatives to the Board's proposal. \\17\\ For example, a...
49 CFR Appendix A to Part 395 - Electronic On-Board Recorder Performance Specifications
Code of Federal Regulations, 2011 CFR
2011-10-01
... (to home office or wireless service provider). External Sensor Issue NO_ECM no ECM data No sensory information received from vehicle's Engine Control Module (ECM). External Sensor Issue ECM_ID ECM ID number mismatch ECM identification/serial number mismatch (with preprogrammed information). 2. Communications...
Direct Certification Process. Nourishing News. Volume 4, Issue 3
ERIC Educational Resources Information Center
Idaho State Department of Education, 2009
2009-01-01
This newsletter discusses the Electronic Direct Certification process and provides additional insight as needed. Under this New Direct Certification process school districts compare information from their student information system to Idaho State Department of Health and Welfare database to certify children receiving Food Stamps or TAFI as…
Implantable, Ingestible Electronic Thermometer
NASA Technical Reports Server (NTRS)
Kleinberg, Leonard
1987-01-01
Small quartz-crystal-controlled oscillator swallowed or surgically implanted provides continuous monitoring of patient's internal temperature. Receiver placed near patient measures oscillator frequency, and temperature inferred from previously determined variation of frequency with temperature. Frequency of crystal-controlled oscillator varies with temperature. Circuit made very small and implanted or ingested to measure internal body temperature.
Electronic reminders improve procedure documentation compliance and professional fee reimbursement.
Kheterpal, Sachin; Gupta, Ruchika; Blum, James M; Tremper, Kevin K; O'Reilly, Michael; Kazanjian, Paul E
2007-03-01
Medicolegal, clinical, and reimbursement needs warrant complete and accurate documentation. We sought to identify and improve our compliance rate for the documentation of arterial catheterization in the perioperative setting. We first reviewed 12 mo of electronic anesthesia records to establish a baseline compliance rate for arterial catheter documentation. Residents and Certified Registered Nurse Anesthetists were randomly assigned to a control group and experimental group. When surgical incision and anesthesia end were documented in the electronic record keeper, a reminder routine checked for an invasive arterial blood pressure tracing. If a case used an arterial catheter, but no procedure note was observed, the resident or Certified Registered Nurse Anesthetist assigned to the case was sent an automated alphanumeric pager and e-mail reminder. Providers in the control group received no pager or e-mail message. After 2 mo, all staff received the reminders. A baseline compliance rate of 80% was observed (1963 of 2459 catheters documented). During the 2-mo study period, providers in the control group documented 152 of 202 (75%) arterial catheters, and the experimental group documented 177 of 201 (88%) arterial lines (P < 0.001). After all staff began receiving reminders, 309 of 314 arterial lines were documented in a subsequent 2 mo period (98%). Extrapolating this compliance rate to 12 mo of expected arterial catheter placement would result in an annual incremental $40,500 of professional fee reimbursement. The complexity of the tertiary care process results in documentation deficiencies. Inexpensive automated reminders can drastically improve compliance without the need for complicated negative or positive feedback.
Saidinejad, Mohsen; Teach, Stephen J; Chamberlain, James M
2012-06-01
The Internet may represent an opportunity for health care providers in the emergency department (ED) to deliver discharge instructions and after-care educational materials electronically to patients and their caregivers. The objectives of this study were to determine the prevalence of Internet access and use among caregivers of children who visit the ED and to evaluate their interest in receiving after-care communication and educational material electronically. We distributed a self-administered survey to a convenience sample of English-speaking caregivers of children who presented to the ED of an urban, academic, pediatric hospital during November and December 2009. The survey was distributed to and completed by 509 English-speaking respondents. Of the participants, 423 (83.1%) of 509 identified themselves as black/African American, and 397 (77.9%) of 509 were publicly insured. Of the participants, 503 of 509 (98.9%; 95% confidence interval [CI], 97.9%-99.8%) reported that they have access to the Internet. Of the participants with Internet access, 312 of 503 (62.0%; 95% CI, 57.8%-66.3%) have access at home, 166 of 503 (33.0%; 95% CI, 28.9%-33.1%) have access at work, and 112 of 503 (22.3%; 95% CI, 18.6%-25.9%) have access by mobile phone. When asked about electronic communication and social networking, 483 of 503 (96.0%; 95% CI, 94.3%-97.7%) have an e-mail account, and 304 of 503 (60.4%; 95% CI, 56.2%-64.7%) have a Facebook account. Furthermore, 353 of 503 (70.1%; 95% CI, 66.2%-74.2%) reported accessing the Internet daily, whereas 128 of 503 (25.4%; 95% CI, 21.6%-29.3%) access the Internet at least 2 to 6 times per week. Among all respondents, interest in receiving communication from the ED only electronically was expressed by 259 of 509 participants (50.9%; 95% CI, 46.5%-55.2%). Approximately one third of the participants (173/509 [34%; 95% CI, 29.9%-38.1%]) expressed interest in an electronic channel for communication between the ED and their child's patient primary care provider. In this predominantly minority and economically disadvantaged population of caregivers presenting to an urban pediatric ED, a large majority reported regular access to the Internet and willingness and ability to receive communication from the ED via electronic means.
Gamma-ray blind beta particle probe
Weisenberger, Andrew G.
2001-01-01
An intra-operative beta particle probe is provided by placing a suitable photomultiplier tube (PMT), micro channel plate (MCP) or other electron multiplier device within a vacuum housing equipped with: 1) an appropriate beta particle permeable window; and 2) electron detection circuitry. Beta particles emitted in the immediate vicinity of the probe window will be received by the electron multiplier device and amplified to produce a detectable signal. Such a device is useful as a gamma insensitive, intra-operative, beta particle probe in surgeries where the patient has been injected with a beta emitting radiopharmaceutical. The method of use of such a device is also described, as is a position sensitive such device.
AVIRIS onboard data handling and control
NASA Technical Reports Server (NTRS)
Steinkraus, Ronald E.; Hickok, Roger W.
1987-01-01
The timing and flow of detector and ancillary data for the Airborne Visible/Infrared imaging spectrometer (AVIRIS) are controlled within the instrument by its digital electronics assembly. In addition to providing detector and signal chain timing, the digital electronics receives, formats, and rate-buffers digitized science data; collects and formats ancillary (calibration and engineering) data; and merges both into a single tape record. Overall AVIRIS data handling is effected by a combination of dedicated digital electronics to control instrument timing, image data flow, and data rate buffering and a microcomputer programmed to handle real-time control of instrument mechanisms and the coordinated preparation of ancillary data.
Electrical power converter method and system employing multiple output converters
Beihoff, Bruce C [Wauwatosa, WI; Radosevich, Lawrence D [Muskego, WI; Meyer, Andreas A [Richmond Heights, OH; Gollhardt, Neil [Fox Point, WI; Kannenberg, Daniel G [Waukesha, WI
2007-05-01
A support may receive one or more power electronic circuits. The support may aid in removing heat from the circuits through fluid circulating through the support. The support, in conjunction with other packaging features may form a shield from both external EMI/RFI and from interference generated by operation of the power electronic circuits. Features may be provided to permit and enhance connection of the circuitry to external circuitry, such as improved terminal configurations. Modular units may be assembled that may be coupled to electronic circuitry via plug-in arrangements or through interface with a backplane or similar mounting and interconnecting structures.
Fluid cooled vehicle drive module
Beihoff, Bruce C.; Radosevich, Lawrence D.; Meyer, Andreas A.; Gollhardt, Neil; Kannenberg, Daniel G.
2005-11-15
An electric vehicle drive includes a support may receive one or more power electronic circuits. The support may aid in removing heat from the circuits through fluid circulating through the support. The support, in conjunction with other packaging features may form a shield from both external EM/RFI and from interference generated by operation of the power electronic circuits. Features may be provided to permit and enhance connection of the circuitry to external circuitry, such as improved terminal configurations. Modular units may be assembled that may be coupled to electronic circuitry via plug-in arrangements or through interface with a backplane or similar mounting and interconnecting structures.
Electrical power converter method and system employing multiple-output converters
Beihoff, Bruce C.; Radosevich, Lawrence D.; Meyer, Andreas A.; Gollhardt, Neil; Kannenberg, Daniel G.
2006-03-21
A support may receive one or more power electronic circuits. The support may aid in removing heat from the circuits through fluid circulating through the support. The support, in conjunction with other packaging features may form a shield from both external EMI/RFI and from interference generated by operation of the power electronic circuits. Features may be provided to permit and enhance connection of the circuitry to external circuitry, such as improved terminal configurations. Modular units may be assembled that may be coupled to electronic circuitry via plug-in arrangements or through interface with a backplane or similar mounting and interconnecting structures.
Buckley, Thomas; Stasa, Helen; Cashin, Andrew; Stuart, Meg; Dunn, Sandra V
2015-02-01
The purpose of this study was to investigate the sources, both print and electronic formats, which Australian nurse practitioners (NPs) currently use to obtain information regarding quality use of medicines (QUM). An additional aim was to document NPs' preferences for continuing education in relation to QUM. A national electronic survey of Australian NPs was conducted in 2007 and again in 2010. Eighty percent of respondents accessed information on QUM from professional literature, which may include scholarly journal articles, reports, and independent publications. There was a decrease in the percentage of respondents who obtained information from drug industry representatives. NPs prefer to receive medicines information in an electronic form, rather than a paper-based version, and over the time period more NPs are utilizing electronic sources rather than paper. These findings provide important insights into medical information products for the developers who may be able to use these results to ensure that their products meet the needs of NP clinicians. Additionally, the finding that NPs prefer to receive their continuing information related to medicines in electronic format, but also highly value conference proceedings, may help to inform future planning of NP education needs in relation to QUM. ©2014 American Association of Nurse Practitioners.
Funsten, Herbert O.; Baldonado, Juan R.; Dors, Eric E.; Harper, Ronnie W.; Skoug, Ruth M.
2006-03-28
An apparatus for electron multiplication by transmission that is designed with at least one foil having a front side for receiving incident particles and a back side for transmitting secondary electrons that are produced from the incident particles transiting through the foil. The foil thickness enables the incident particles to travel through the foil and continue on to an anode or to a next foil in series with the first foil. The foil, or foils, and anode are contained within a supporting structure that is attached within an evacuated enclosure. An electrical power supply is connected to the foil, or foils, and the anode to provide an electrical field gradient effective to accelerate negatively charged incident particles and the generated secondary electrons through the foil, or foils, to the anode for collection.
Advanced algorithms for ionosphere modelling in GNSS applications within AUDITOR project
NASA Astrophysics Data System (ADS)
Goss, Andreas; Erdogan, Eren; Schmidt, Michael; Garcia-Rigo, Alberto; Hernandez-Pajares, Manuel; Lyu, Haixia; Nohutcu, Metin
2017-04-01
The H2020 project AUDITOR of the European Union started on January 1st 2016, with the participation of several European institutions and universities. The goal of the project is the implementation of a novel precise positioning technique, based on augmentation data in a customized GNSS receiver. Therefore more sophisticated ionospheric models have to be developed and implemented to increase the accuracy in real-time at the user side. Since the service should be available for the public, we use public data from GNSS networks (e.g. IGS, EUREF). The contributions of DGFI-TUM and UPC are focusing on the development of high accuracy GNSS algorithms to provide enhanced ionospheric corrections. This includes two major issues: 1. The existing mapping function to convert the slant total electron content (STEC) measurable by GNSS into the vertical total electron content (VTEC) is based on a so called single layer model (SLM), where all electrons are concentrated on an infinitesimal thin layer with fixed height (between 350 and 450 kilometers). This quantity is called the effective ionospheric height (EIH). An improvement of the mapping function shall be achieved by estimating more realistic numerical values for the EIH by means of a voxel-based tomographic model (TOMION). 2. The ionospheric observations are distributed rather unevenly over the globe and within specific regions. This inhomogeneous distribution is handled by data adaptive B-Spline approaches, with polynomial and trigonometric functions used for the latitude and longitude representations to provide high resolution VTEC maps for global and regional purposes. A Kalman filter is used as sequential estimator. The unknown parameters of the filter state vector are composed of the B-spline coefficients as well as the satellite and receiver DCBs. The resulting high accuracy ionosphere products will be disseminated to the users via downlink from a dedicated server to a receiver site. In this context, an appropriate message (e.g. VTEC grid) has been defined by DGFI and UPC which can directly be used to provide ionospheric corrections for positioning and navigation. In this contribution we present the total production chain from GNSS STEC observations to the dissemination of the ionospheric message to the user of the AUDITOR customized receiver.
CARINA Satellite Mission to Investigate the Upper Atmosphere below the F-Layer Ionosphere
NASA Astrophysics Data System (ADS)
Siefring, C. L.; Bernhardt, P. A.; Briczinski, S. J., Jr.; Huba, J.; Montgomery, J. A., Jr.
2017-12-01
A new satellite design permits broad science measurements from the ocean to the ionosphere by flying below the F-Layer. The satellite called CARINA for Coastal-Ocean, Assimilation, Radio, Ionosphere, Neutral-Drag, and Atmospherics. The unique system capabilities are long duration orbits below the ionosphere and a HF receiver to measure broadband signals. The CARINA science products include recording the ocean surface properties, data for assimilation into global ionosphere models, radio wave propagation measurements, in-situ observations of ionospheric structures, validating neutral drag models and theory, and broadband atmospheric lightning characterization. CARINA will also measure nonlinear wave-generation using ionospheric modification sites in Alaska, Norway, Puerto Rico, and Russia and collaborate with geophysics HF radars (such as Super-DARN) for system calibration. CARINA is a linear 6-U CubeSat with a long antenna extended in the wake direction. The CARINA science mission is supported by three instruments. First, the Electric Field Instrument (EFI) is a radio receiver covering the 2 to 18 MHz range. The receiver can capture both narrow and wide bandwidths for up to 10 minutes. EFI is designed to provide HF signal strength and phase, radar Doppler shift and group delay, and electron plasma density from photoelectron excited plasma waves. Second a Ram Langmuir Probe (RLP) measures high-resolution ion currents at a 10 kHz rate. These measurements yield electron and ion density at the spacecraft. Finally, the Orbiting GPS Receiver (OGR) provides dual frequency GPS position with ionosphere correction. OGR also measures total electron content above the spacecraft and L-Band scintillations. CARINA will be the lowest satellite in orbit at 250 km altitude, <0.01 eccentricity, and up to 4-month lifetime. The design supports unique capabilities with broad applications to the geosciences. Remote sensing of the ocean will sample the HF signals scattered from the rough sea surface to measure the wave height spectrum over large areas. CARINA will provide an enhanced understanding of HF system limiting phenomena such as travelling ionospheric disturbances, field aligned irregularities, sporadic-E and bottomside ionosphere structures.This work supported by the Naval Research Laboratory Base Program.
Electronic medical devices: a primer for pathologists.
Weitzman, James B
2003-07-01
Electronic medical devices (EMDs) with downloadable memories, such as implantable cardiac pacemakers, defibrillators, drug pumps, insulin pumps, and glucose monitors, are now an integral part of routine medical practice in the United States, and functional organ replacements, such as the artificial heart, pancreas, and retina, will most likely become commonplace in the near future. Often, EMDs end up in the hands of the pathologist as a surgical specimen or at autopsy. No established guidelines for systematic examination and reporting or comprehensive reviews of EMDs currently exist for the pathologist. To provide pathologists with a general overview of EMDs, including a brief history; epidemiology; essential technical aspects, indications, contraindications, and complications of selected devices; potential applications in pathology; relevant government regulations; and suggested examination and reporting guidelines. Articles indexed on PubMed of the National Library of Medicine, various medical and history of medicine textbooks, US Food and Drug Administration publications and product information, and specifications provided by device manufacturers. Studies were selected on the basis of relevance to the study objectives. Descriptive data were selected by the author. Suggested examination and reporting guidelines for EMDs received as surgical specimens and retrieved at autopsy. Electronic medical devices received as surgical specimens and retrieved at autopsy are increasing in number and level of sophistication. They should be systematically examined and reported, should have electronic memories downloaded when indicated, will help pathologists answer more questions with greater certainty, and should become an integral part of the formal knowledge base, research focus, training, and practice of pathology.
ALMA Band 5 receiver cartridge. Design, performance, and commissioning
NASA Astrophysics Data System (ADS)
Belitsky, V.; Bylund, M.; Desmaris, V.; Ermakov, A.; Ferm, S.-E.; Fredrixon, M.; Krause, S.; Lapkin, I.; Meledin, D.; Pavolotsky, A.; Rashid, H.; Shafiee, S.; Strandberg, M.; Sundin, E.; Aghdam, P. Yadranjee; Hesper, R.; Barkhof, J.; Bekema, M. E.; Adema, J.; Haan, R. de; Koops, A.; Boland, W.; Yagoubov, P.; Marconi, G.; Siringo, G.; Humphreys, E.; Tan, G. H.; Laing, R.; Testi, L.; Mroczkowski, T.; Wild, W.; Saini, K. S.; Bryerton, E.
2018-04-01
We describe the design, performance, and commissioning results for the new ALMA Band 5 receiver channel, 163-211 GHz, which is in the final stage of full deployment and expected to be available for observations in 2018. This manuscript provides the description of the new ALMA Band 5 receiver cartridge and serves as a reference for observers using the ALMA Band 5 receiver for observations. At the time of writing this paper, the ALMA Band 5 Production Consortium consisting of NOVA Instrumentation group, based in Groningen, NL, and GARD in Sweden have produced and delivered to ALMA Observatory over 60 receiver cartridges. All 60 cartridges fulfil the new more stringent specifications for Band 5 and demonstrate excellent noise temperatures, typically below 45 K single sideband (SSB) at 4 K detector physical temperature and below 35 K SSB at 3.5 K (typical for operation at the ALMA Frontend), providing the average sideband rejection better than 15 dB, and the integrated cross-polarization level better than -25 dB. The 70 warm cartridge assemblies, hosting Band 5 local oscillator and DC bias electronics, have been produced and delivered to ALMA by NRAO. The commissioning results confirm the excellent performance of the receivers.
The ImmProve Project: Leveraging electronic health record data to promote immunization delivery
Bundy, David G.; Persing, Nichole M.; Solomon, Barry S.; King, Tracy M.; Murakami, Peter; Thompson, Richard E.; Engineer, Lilly D.; Lehmann, Christoph U.; Miller, Marlene R.
2013-01-01
Objective Though an essential pediatric preventive service, immunizations are challenging to deliver reliably. Our objective was to measure the impact on pediatric immunization rates of providing clinicians with electronic health record-derived immunization prompting. Methods Operating in a large, urban, hospital-based pediatric primary care clinic, we evaluated 2 interventions to improve immunization delivery to children ages 2, 6, and 13 years: point-of-care, patient-specific electronic clinical decision support (CDS) when children overdue for immunizations presented for care and provider-specific bulletins listing children overdue for immunizations. Results Overall, the proportion of children up-to-date for a composite of recommended immunizations at ages 2, 6, and 13 years was not different in the intervention (CDS active) and historical control (CDS not active) periods; historical immunization rates were high. The proportion of children receiving 2 doses of hepatitis A immunization prior to their second birthday was significantly improved during the intervention period. Human papilloma virus (HPV) immunization delivery was low during both control and intervention periods and was unchanged for 13-year-olds. For 14-year-olds, however, 4 of the 5 highest quarterly rates of complete HPV immunization occurred in the final year of the intervention. Provider-specific bulletins listing children overdue for immunizations increased the likelihood of identified children receiving catch-up hepatitis A immunizations (hazard ratio: 1.32 [95% confidence interval (CI): 1.12–1.56]); results for HPV and the composite of recommended immunizations were of a similar magnitude but not statistically significant. Conclusions In our patient population, with high baseline uptake of recommended immunizations, electronic health record-derived immunization prompting had a limited effect on immunization delivery. Benefit was more clearly demonstrated for newer immunizations with lower baseline uptake. PMID:23726754
Improving immunization delivery using an electronic health record: the ImmProve project.
Bundy, David G; Persing, Nichole M; Solomon, Barry S; King, Tracy M; Murakami, Peter N; Thompson, Richard E; Engineer, Lilly D; Lehmann, Christoph U; Miller, Marlene R
2013-01-01
Though an essential pediatric preventive service, immunizations are challenging to deliver reliably. Our objective was to measure the impact on pediatric immunization rates of providing clinicians with electronic health record-derived immunization prompting. Operating in a large, urban, hospital-based pediatric primary care clinic, we evaluated 2 interventions to improve immunization delivery to children ages 2, 6, and 13 years: point-of-care, patient-specific electronic clinical decision support (CDS) when children overdue for immunizations presented for care, and provider-specific bulletins listing children overdue for immunizations. Overall, the proportion of children up to date for a composite of recommended immunizations at ages 2, 6, and 13 years was not different in the intervention (CDS active) and historical control (CDS not active) periods; historical immunization rates were high. The proportion of children receiving 2 doses of hepatitis A immunization before their second birthday was significantly improved during the intervention period. Human papillomavirus (HPV) immunization delivery was low during both control and intervention periods and was unchanged for 13-year-olds. For 14-year-olds, however, 4 of the 5 highest quarterly rates of complete HPV immunization occurred in the final year of the intervention. Provider-specific bulletins listing children overdue for immunizations increased the likelihood of identified children receiving catch-up hepatitis A immunizations (hazard ratio 1.32; 95% confidence interval 1.12-1.56); results for HPV and the composite of recommended immunizations were of a similar magnitude but not statistically significant. In our patient population, with high baseline uptake of recommended immunizations, electronic health record-derived immunization prompting had a limited effect on immunization delivery. Benefit was more clearly demonstrated for newer immunizations with lower baseline uptake. Copyright © 2013 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.
Electron beam diagnostic system using computed tomography and an annular sensor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elmer, John W.; Teruya, Alan T.
2015-08-11
A system for analyzing an electron beam including a circular electron beam diagnostic sensor adapted to receive the electron beam, the circular electron beam diagnostic sensor having a central axis; an annular sensor structure operatively connected to the circular electron beam diagnostic sensor, wherein the sensor structure receives the electron beam; a system for sweeping the electron beam radially outward from the central axis of the circular electron beam diagnostic sensor to the annular sensor structure wherein the electron beam is intercepted by the annular sensor structure; and a device for measuring the electron beam that is intercepted by themore » annular sensor structure.« less
Electron beam diagnostic system using computed tomography and an annular sensor
Elmer, John W.; Teruya, Alan T.
2014-07-29
A system for analyzing an electron beam including a circular electron beam diagnostic sensor adapted to receive the electron beam, the circular electron beam diagnostic sensor having a central axis; an annular sensor structure operatively connected to the circular electron beam diagnostic sensor, wherein the sensor structure receives the electron beam; a system for sweeping the electron beam radially outward from the central axis of the circular electron beam diagnostic sensor to the annular sensor structure wherein the electron beam is intercepted by the annular sensor structure; and a device for measuring the electron beam that is intercepted by the annular sensor structure.
Design, fabrication, test and delivery of a K-band antenna breadboard model
NASA Technical Reports Server (NTRS)
1974-01-01
The results of a research effort to develop a Ku-Band single channel monopulse antenna with significant improvements in efficiency and bandwidth are reported. A single aperture, multimode horn, utilized in a near field Cassegrainian configuration, was the technique selected for achieving the desired efficiency and bandwidth performance. In order to provide wide polarization flexibility, a wire grid, space filter polarizer was developed. A solid state switching network with appropriate driving electronics provides the receive channel sum and difference signal interface with an existing Apollo type tracking electronics subsystem. A full scale breadboard model of the antenna was fabricated and tested. Performance of the model was well within the requirements and goals of the contract.
Memory-built-in quantum cloning in a hybrid solid-state spin register
NASA Astrophysics Data System (ADS)
Wang, W.-B.; Zu, C.; He, L.; Zhang, W.-G.; Duan, L.-M.
2015-07-01
As a way to circumvent the quantum no-cloning theorem, approximate quantum cloning protocols have received wide attention with remarkable applications. Copying of quantum states to memory qubits provides an important strategy for eavesdropping in quantum cryptography. We report an experiment that realizes cloning of quantum states from an electron spin to a nuclear spin in a hybrid solid-state spin register with near-optimal fidelity. The nuclear spin provides an ideal memory qubit at room temperature, which stores the cloned quantum states for a millisecond under ambient conditions, exceeding the lifetime of the original quantum state carried by the electron spin by orders of magnitude. The realization of a cloning machine with built-in quantum memory provides a key step for application of quantum cloning in quantum information science.
Memory-built-in quantum cloning in a hybrid solid-state spin register.
Wang, W-B; Zu, C; He, L; Zhang, W-G; Duan, L-M
2015-07-16
As a way to circumvent the quantum no-cloning theorem, approximate quantum cloning protocols have received wide attention with remarkable applications. Copying of quantum states to memory qubits provides an important strategy for eavesdropping in quantum cryptography. We report an experiment that realizes cloning of quantum states from an electron spin to a nuclear spin in a hybrid solid-state spin register with near-optimal fidelity. The nuclear spin provides an ideal memory qubit at room temperature, which stores the cloned quantum states for a millisecond under ambient conditions, exceeding the lifetime of the original quantum state carried by the electron spin by orders of magnitude. The realization of a cloning machine with built-in quantum memory provides a key step for application of quantum cloning in quantum information science.
Non-Electronic Radio Front-End (NERF)
2007-04-01
electro - optic field sensor. The absence of metallic interconnects and the charge isolation provided by the optics removes the soft spots in a traditional receiver. In the proof-of concept experiment, detection of C band electromagnetic signals at 7.38 GHz with a sensitivity of 4.3x10 -3 V/m.Hz(exp 1/2) is demonstrated. The dielectric approach has an added benefit: it reduces physical size of the front end an important benefit in mobile applications. DIELECTRIC RESONATOR ANTENNA, PHOTONICALLY ISOLATED ANTENNA RECEIVER, ELECTRO - OPTIC DIELECTRIC ANTENNA,
NASA Astrophysics Data System (ADS)
Andreeva, Elena; Tereshchenko, Evgeniy; Nazarenko, Marina; Nesterov, Ivan; Kozharin, Maksim; Padokhin, Artem; Tumanova, Yulia
2016-04-01
The ionospheric radio tomography is an efficient method for electron density imaging in the different geographical regions of the world under different space weather conditions. The input for the satellite-based ionospheric radio tomography is provided by the signals that are transmitted from the navigational satellites and recorded by the chains or networks of ground receivers. The low-orbiting (LO) radio tomography employs the 150/400 MHz radio transmissions from the Earth's orbiters (like the Russian Tsikada/Parus and American Transit) flying at a height of ~1000 km above the Earth in the nearly polar orbits. The phases of the signals from a moving satellite which are recorded by the chains of ground receivers oriented along the satellite path form the families of linear integrals of electron density along the satellite-receiver rays that are used as the input data for LORT. The LO tomographic inversion of these data by phase difference method yields the 2D distributions of the ionospheric plasma in the vertical plane containing the receiving chain and the satellite path. LORT provides vertical resolution of 20-30 km and horizontal resolution of 30-40 km. The high-orbiting (HO) radio tomography employs the radio transmissions from the GPS/GLONASS satellites and enables 4D imaging of the ionosphere (3 spatial coordinates and time). HORT has a much wider spatial coverage (almost worldwide) and provides continuous time series of the reconstructions. However, the spatial resolution of HORT is lower (~100 km horizontally with a time step 60-20 min). In the regions with dense receiving networks (Europe, USA, Alaska, Japan), the resolution can be increased to 30-50 km with a time interval of 30-10 min. To date, the extensive RT data collected from the existing RT chains and networks enable a thorough analysis of both the regular and sporadic ionospheric features which are observed systematically or appear spontaneously, whose origin is fairly well understood or requires a dedicated study. We present the examples of the both types of the structures. We show a collection of different ionospheric structures under different space weather conditions: the ionization troughs, with their widely varying shapes, depths, positions, and internal distributions of plasma; isolated spots of the increased or decreased electron density, sharp wall-like density gradients, blobs, wavelike disturbances on different spatiotemporal scales etc. We demonstrate the series of the local isolated irregularities which are observed during both the quiet and disturbed days. We show the examples of the ionospheric plasma distributions strikingly varying during the geomagnetic storms. Some of the RT data are compared to the independent observations by the ionosondes. We also present the examples of RT images comparison with the UV spectroscopy data.
2012-01-01
Background Patients have typically received health care through face-to-face encounters. However, expansion of electronic communication and electronic health records (EHRs) provide alternative means for patient and physicians to interact. Electronic consultations may complement regular healthcare by providing “better, faster, cheaper” processes for diagnosing, treating, and monitoring health conditions. Virtual consultation between physicians may provide a method of streamlining care, potentially saving patients the time and expense of added visits. The purpose of this study was to compare physician usage and patient satisfaction with virtual consultations (VCs) with traditional consultations (TCs) facilitated within an EHR. Methods We conducted an observational case–control survey study within Kaiser Permanente, Colorado. A sample of patients who had VCs requested by physicians (N = 270) were matched with patients who had TCs requested by physicians (N = 270), by patient age, gender, reason for the consult, and specialty department. These patients (VC and TC), were invited to participate in a satisfaction survey. In addition, 205 primary care physicians who submitted a VC or TC were surveyed. Results During the study period, 58,146 VC or TC were requested (TC = 96.3%). Patients who completed a satisfaction survey (267 out of 540 patients, 49.4% response rate) indicated they were satisfied with their care, irrespective of the kind of consult (mean 10-point Likert score of 8.5). 88 of 205 primary care physicians surveyed (42.9%) returned at least one survey; VC and TC survey response rates and consulted departments were comparable (p = 0.13). More TCs than VCs requested transfer of patient care (p = 0.03), assistance with diagnosis (p = 0.04) or initiating treatment (p =0.04). Within 3 weeks of the consultation request, 72.1% of respondents reported receiving information from VCs, compared with 33.9% of the TCs (p < 0.001). Utility of information provided by consultants and satisfaction with consultations did not differ between VCs and TCs. Conclusions Referring physicians received information from consultants more quickly from VCs compared with TCs, but the value and application of information from both types of consultations were similar. VCs may decrease the need for face-to-face specialty encounters without a decrease in the patient’s perception of care. PMID:22769592
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zheng, Y; Chang, A; Liu, Y
Purpose: Electron beams are commonly used for boost radiation following whole breast irradiation (WBI) to improve the in-breast local control. Proton beams have a finite range and a sharper distal dose falloff compared to electron beams, thus potentially sparing more heart and lung in breast treatment. The purpose of the study is to compare protons with electrons for boost breast treatment in terms of target coverage and normal tissue sparing. Methods: Six breast cancer patients were included in this study. All women received WBI to 45–50 Gy, followed by a 10–16.2 Gy boost with standard fractionation. If proton beams weremore » used for the boost treatment, an electron plan was retrospectively generated for comparison using the same CT set and structures, and vice versa if electron beams were used for treatment. Proton plans were generated using the treatment planning system (TPS) with two to three uniform scanning proton beams. Electron plans were generated using the Pinnacle TPS with one single en face beam. Dose-volume histograms (DVH) were calculated and compared between proton and electron boost plans. Results: Proton plans show a similar boost target coverage, similar skin dose, and much better heart and lung sparing. For an example patient, V95% for PTV was 99.98% and skin (5 mm shell) received a max dose close to the prescription dose for both protons and electrons; however, V2 and V5 for the ipsilateral lung and heart were 37.5%, 17.9% and 19.9%, 4.9% respectively for electrons, but were essentially 0 for protons. Conclusions: This dosimetric comparison demonstrates that while both proton therapy and electron therapy provided similar coverage and skin dose, proton therapy could largely reduce the dose to lung and heart, thus leading to potential less side effects.« less
A Curriculum Model for Teaching Telecommunications to Middle and Secondary School Students.
ERIC Educational Resources Information Center
Daughenbaugh, Richard L.
This curriculum guide is intended for use in teaching a unit on telecommunications to students with a basic understanding of computing. Introductory materials spell out the purpose of the unit--to provide an introduction to the sending and receiving of electronic information using a personal computer system and the telephone communications…
Federal support for state and local response operations - PHE
Electronic Benefits Transfer program, which provides summertime nutrition assistance to children who receive 15, a USDA Food and Nutrition Service nutritionist presented USDA nutrition information and menu Nutrition Program for Women, Infants, and Children (WIC) funds to conduct lead testing for WIC participants
The Coordinator's Dilemma: Between an Electronic Janitor and a Pedagogical Leader
ERIC Educational Resources Information Center
Quiroga, Marta
2008-01-01
Since 1992, the Chilean Ministry of Education is developing a sustained process to incorporate ICT (Information and Communications Technology) into schools by providing equipment and training to faculty members. Schools appoint one of their teachers as a coordinator who will then receive an intense technological and pedagogical training. The…
Code of Federal Regulations, 2012 CFR
2012-10-01
... if the State has chosen to pay such incentives; (7) Maintaining accounts receivable on all amounts... interfacing with State financial management and expenditure information; (9) Accepting electronic case...) Providing management information on all IV-D cases under the State plan from initial referral or application...
Code of Federal Regulations, 2014 CFR
2014-10-01
... if the State has chosen to pay such incentives; (7) Maintaining accounts receivable on all amounts... interfacing with State financial management and expenditure information; (9) Accepting electronic case...) Providing management information on all IV-D cases under the State plan from initial referral or application...
Code of Federal Regulations, 2013 CFR
2013-10-01
... if the State has chosen to pay such incentives; (7) Maintaining accounts receivable on all amounts... interfacing with State financial management and expenditure information; (9) Accepting electronic case...) Providing management information on all IV-D cases under the State plan from initial referral or application...
Kronish, Ian M; Moise, Nathalie; McGinn, Thomas; Quan, Yan; Chaplin, William; Gallagher, Benjamin D; Davidson, Karina W
2016-11-01
To appropriately manage uncontrolled hypertension, clinicians must decide whether blood pressure (BP) is above goal due to a need for additional medication or to medication nonadherence. Yet, clinicians are poor judges of adherence, and uncertainty about adherence may promote inertia with respect to medication modification. We aimed to determine the effect of sharing electronically-measured adherence data with clinicians on the management of uncontrolled hypertension. This was a cluster randomized trial. Twenty-four primary care providers (12 intervention, 12 usual care; cluster units) and 100 patients with uncontrolled hypertension (65 intervention, 35 usual care) were included in the study. At one visit per patient, clinicians in the intervention group received a report summarizing electronically measured adherence to the BP regimen and recommended clinical actions. Clinicians in the control group did not receive a report. The primary outcome was the proportion of visits with appropriate clinical management (i.e., treatment intensification among adherent patients and adherence counseling among nonadherent patients). Secondary outcomes included patient-rated quality of care and communication during the visit. The proportion of visits with appropriate clinical management was higher in the intervention group than the control group (45 out of 65; 69 %) versus (12 out of 35; 34 %; p = 0.001). A higher proportion of adherent patients in the intervention group had their regimen intensified (p = 0.01), and a higher proportion of nonadherent patients in the intervention group received adherence counseling (p = 0.005). Patients in the intervention group were more likely to give their clinician high ratings on quality of care (p = 0.05), and on measures of patient-centered (p = 0.001) and collaborative communication (p = 0.02). Providing clinicians with electronically-measured antihypertensive adherence reports reduces inertia in the management of uncontrolled hypertension. NCT01257347 ; http://clinicaltrials.gov/show/ NCT01257347.
Over-voltage protection system and method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chi, Song; Dong, Dong; Lai, Rixin
An over-voltage protection system includes an electronic valve connected across two terminals of a circuit and an over-voltage detection circuit connected across one of the plurality of semiconductor devices for detecting an over-voltage across the circuit. The electronic valve includes a plurality of semiconductor devices connected in series. The over-voltage detection circuit includes a voltage divider circuit connected to a break-over diode in a way to provide a representative low voltage to the break-over diode and an optocoupler configured to receive a current from the break-over diode when the representative low voltage exceeds a threshold voltage of the break-over diodemore » indicating an over-voltage condition. The representative low voltage provided to the break-over diode represents a voltage across the one semiconductor device. A plurality of self-powered gate drive circuits are connected to the plurality of semiconductor devices, wherein the plurality of self-powered gate drive circuits receive over-voltage triggering pulses from the optocoupler during the over-voltage condition and switch on the plurality of semiconductor devices to bypass the circuit.« less
Global Application of TaiWan Ionospheric Model to Single-Frequency GPS Positioning
NASA Astrophysics Data System (ADS)
Macalalad, E.; Tsai, L. C.; Wu, J.
2012-04-01
Ionospheric delay is one the major sources of error in GPS positioning and navigation. This error in both pseudorange and phase ranges vary depending on the location of observation, local time, season, solar cycle and geomagnetic activity. For single-frequency receivers, this delay is usually removed using ionospheric models. Two of them are the Klobuchar, or broadcast, model and the global ionosphere map (GIM) provided by the International GNSS Service (IGS). In this paper, a three dimensional ionospheric electron (ne) density model derived from FormoSat3/COSMIC GPS Radio Occultation measurements, called the TaiWan Ionosphere Model, is used. It was used to calculate the slant total electron content (STEC) between receiver and GPS satellites to correct the pseudorange single-frequency observations. The corrected pseudorange for every epoch was used to determine a more accurate position of the receiver. Observations were made in July 2, 2011(Kp index = 0-2) in five randomly selected sites across the globe, four of which are IGS stations (station ID: cnmr, coso, irkj and morp) while the other is a low-cost single-frequency receiver located in Chungli City, Taiwan (ID: isls). It was illustrated that TEC maps generated using TWIM exhibited a detailed structure of the ionosphere, whereas Klobuchar and GIM only provided the basic diurnal and geographic features of the ionosphere. Also, it was shown that for single-frequency static point positioning TWIM provides more accurate and more precise positioning than the Klobuchar and GIM models for all stations. The average %error of the corrections made by Klobuchar, GIM and TWIM in DRMS are 3.88%, 0.78% and 17.45%, respectively. While the average %error in VRMS for Klobuchar, GIM and TWIM are 53.55%, 62.09%, 66.02%, respectively. This shows the capability of TWIM to provide a good global 3-dimensional ionospheric model.
Social media, text messaging, and email-preferences of asthma patients between 12 and 40 years old.
Baptist, Alan P; Thompson, Michael; Grossman, Karla Stoermer; Mohammed, Layla; Sy, Annie; Sanders, Georgiana M
2011-10-01
Electronic media such as social media (Facebook, Twitter, MySpace), email, and text messaging could be useful in the management of asthma. However, patient use and preferences for electronic media in asthma management is currently unknown. A survey was sent to asthma patients between 12-40 years of age. The survey collected demographic information, use of electronic media, interest in using electronic media to receive asthma information, and interest in using electronic media to communicate with a health care provider about asthma. Free text entries were encouraged. 145 completed surveys were returned. Text messaging, email, and Facebook were used at least weekly by a majority of respondents (82%, 77%, and 65%, respectively). Email was clearly the most preferred method to receive asthma information and to communicate with a physician. There was some interest in using Facebook or text messaging, whereas Myspace and Twitter had minimal interest. On logistic regression analysis, female and Black or Hispanic participants were more likely to have an interest in the use of electronic media for asthma care. Frequent users (>1X/week) of each electronic media type had greater enthusiasm for their incorporation into asthma care. Free text entries revealed that many participants felt social media sites were for connecting with friends rather than for health care, and privacy concerns were also raised. Electronic media offers a novel way to improve asthma care. Email was the most preferred method, though text messaging and social media sites like Facebook may be appropriate for certain patients.
Millimeter-wave imaging diagnostics systems on the EAST tokamak (invited)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Y. L.; Xie, J. L., E-mail: jlxie@ustc.edu.cn; Yu, C. X.
2016-11-15
Millimeter-wave imaging diagnostics, with large poloidal span and wide radial range, have been developed on the EAST tokamak for visualization of 2D electron temperature and density fluctuations. A 384 channel (24 poloidal × 16 radial) Electron Cyclotron Emission Imaging (ECEI) system in F-band (90-140 GHz) was installed on the EAST tokamak in 2012 to provide 2D electron temperature fluctuation images with high spatial and temporal resolution. A co-located Microwave Imaging Reflectometry (MIR) will be installed for imaging of density fluctuations by December 2016. This “4th generation” MIR system has eight independent frequency illumination beams in W-band (75-110 GHz) driven bymore » fast tuning synthesizers and active multipliers. Both of these advanced millimeter-wave imaging diagnostic systems have applied the latest techniques. A novel design philosophy “general optics structure” has been employed for the design of the ECEI and MIR receiver optics with large aperture. The extended radial and poloidal coverage of ECEI on EAST is made possible by innovations in the design of front-end optics. The front-end optical structures of the two imaging diagnostics, ECEI and MIR, have been integrated into a compact system, including the ECEI receiver and MIR transmitter and receiver. Two imaging systems share the same mid-plane port for simultaneous, co-located 2D fluctuation measurements of electron density and temperature. An intelligent remote-control is utilized in the MIR electronics systems to maintain focusing at the desired radial region even with density variations by remotely tuning the probe frequencies in about 200 μs. A similar intelligent technique has also been applied on the ECEI IF system, with remote configuration of the attenuations for each channel.« less
Millimeter-wave imaging diagnostics systems on the EAST tokamak (invited)
NASA Astrophysics Data System (ADS)
Zhu, Y. L.; Xie, J. L.; Yu, C. X.; Zhao, Z. L.; Gao, B. X.; Chen, D. X.; Liu, W. D.; Liao, W.; Qu, C. M.; Luo, C.; Hu, X.; Spear, A. G.; Luhmann, N. C.; Domier, C. W.; Chen, M.; Ren, X.; Tobias, B. J.
2016-11-01
Millimeter-wave imaging diagnostics, with large poloidal span and wide radial range, have been developed on the EAST tokamak for visualization of 2D electron temperature and density fluctuations. A 384 channel (24 poloidal × 16 radial) Electron Cyclotron Emission Imaging (ECEI) system in F-band (90-140 GHz) was installed on the EAST tokamak in 2012 to provide 2D electron temperature fluctuation images with high spatial and temporal resolution. A co-located Microwave Imaging Reflectometry (MIR) will be installed for imaging of density fluctuations by December 2016. This "4th generation" MIR system has eight independent frequency illumination beams in W-band (75-110 GHz) driven by fast tuning synthesizers and active multipliers. Both of these advanced millimeter-wave imaging diagnostic systems have applied the latest techniques. A novel design philosophy "general optics structure" has been employed for the design of the ECEI and MIR receiver optics with large aperture. The extended radial and poloidal coverage of ECEI on EAST is made possible by innovations in the design of front-end optics. The front-end optical structures of the two imaging diagnostics, ECEI and MIR, have been integrated into a compact system, including the ECEI receiver and MIR transmitter and receiver. Two imaging systems share the same mid-plane port for simultaneous, co-located 2D fluctuation measurements of electron density and temperature. An intelligent remote-control is utilized in the MIR electronics systems to maintain focusing at the desired radial region even with density variations by remotely tuning the probe frequencies in about 200 μs. A similar intelligent technique has also been applied on the ECEI IF system, with remote configuration of the attenuations for each channel.
Borehole optical lateral displacement sensor
Lewis, R.E.
1998-10-20
There is provided by this invention an optical displacement sensor that utilizes a reflective target connected to a surface to be monitored to reflect light from a light source such that the reflected light is received by a photoelectric transducer. The electric signal from the photoelectric transducer is then imputed into electronic circuitry to generate an electronic image of the target. The target`s image is monitored to determine the quantity and direction of any lateral displacement in the target`s image which represents lateral displacement in the surface being monitored. 4 figs.
Ballistic-Electron-Emission Microscope
NASA Technical Reports Server (NTRS)
Kaiser, William J.; Bell, L. Douglas
1990-01-01
Ballistic-electron-emission microscope (BEEM) employs scanning tunneling-microscopy (STM) methods for nondestructive, direct electrical investigation of buried interfaces, such as interface between semiconductor and thin metal film. In BEEM, there are at least three electrodes: emitting tip, biasing electrode, and collecting electrode, receiving current crossing interface under investigation. Signal-processing device amplifies electrode signals and converts them into form usable by computer. Produces spatial images of surface by scanning tip; in addition, provides high-resolution images of buried interface under investigation. Spectroscopic information extracted by measuring collecting-electrode current as function of one of interelectrode voltages.
Innovative, wearable snap connector technology for improved device networking in electronic garments
NASA Astrophysics Data System (ADS)
Kostrzewski, Andrew A.; Lee, Kang S.; Gans, Eric; Winterhalter, Carole A.; Jannson, Tomasz P.
2007-04-01
This paper discusses Physical Optics Corporation's (POC) wearable snap connector technology that provides for the transfer of data and power throughout an electronic garment (e-garment). These connectors resemble a standard garment button and can be mated blindly with only one hand. Fully compatible with military clothing, their application allows for the networking of multiple electronic devices and an intuitive method for adding/removing existing components from the system. The attached flexible cabling also permits the rugged snap connectors to be fed throughout the standard webbing found in military garments permitting placement in any location within the uniform. Variations of the snap electronics/geometry allow for integration with USB 2.0 devices, RF antennas, and are capable of transferring high bandwidth data streams such as the 221 Mbps required for VGA video. With the trend towards providing military officers with numerous electronic devices (i.e., heads up displays (HMD), GPS receiver, PDA, etc), POC's snap connector technology will greatly improve cable management resulting in a less cumbersome uniform. In addition, with electronic garments gaining widespread adoption in the commercial marketplace, POC's technology is finding applications in such areas as sporting good manufacturers and video game technology.
Analysis of Multi-Antenna GNSS Receiver Performance under Jamming Attacks.
Vagle, Niranjana; Broumandan, Ali; Lachapelle, Gérard
2016-11-17
Although antenna array-based Global Navigation Satellite System (GNSS) receivers can be used to mitigate both narrowband and wideband electronic interference sources, measurement distortions induced by array processing methods are not suitable for high precision applications. The measurement distortions have an adverse effect on the carrier phase ambiguity resolution, affecting the navigation solution. Depending on the array attitude information availability and calibration parameters, different spatial processing methods can be implemented although they distort carrier phase measurements in some cases. This paper provides a detailed investigation of the effect of different array processing techniques on array-based GNSS receiver measurements and navigation performance. The main novelty of the paper is to provide a thorough analysis of array-based GNSS receivers employing different beamforming techniques from tracking to navigation solution. Two beamforming techniques, namely Power Minimization (PM) and Minimum Power Distortionless Response (MPDR), are being investigated. In the tracking domain, the carrier Doppler, Phase Lock Indicator (PLI), and Carrier-to-Noise Ratio (C/N₀) are analyzed. Pseudorange and carrier phase measurement distortions and carrier phase position performance are also evaluated. Performance analyses results from simulated GNSS signals and field tests are provided.
Learmonth, Yvonne C; Adamson, Brynn C; Balto, Julia M; Chiu, Chung-Yi; Molina-Guzman, Isabel M; Finlayson, Marcia; Riskin, Barry J; Motl, Robert W
2017-10-01
There is increasing recognition of the benefits of exercise in individuals with multiple sclerosis (MS), yet the MS population does not engage in sufficient amounts of exercise to accrue health benefits. There has been little qualitative inquiry to establish the preferred format and source for receiving exercise information from health-care providers among persons with MS. We sought to identify the desired and preferred format and source of exercise information for persons with MS that can be delivered through health-care providers. Participants were adults with MS who had mild or moderate disability and participated in a range of exercise levels. All participants lived in the Midwest of the United States. Fifty semi-structured interviews were conducted and analysed using thematic analysis. Two themes emerged, (i) approach for receiving exercise promotion and (ii) ideal person for promoting exercise. Persons with MS want to receive exercise information through in-person consultations with health-care providers, print media and electronic media. Persons with MS want to receive exercise promotion from health-care providers with expertise in MS (ie neurologists) and with expertise in exercise (eg physical therapists). These data support the importance of understanding how to provide exercise information to persons with MS and identifying that health-care providers including neurologists and physical therapists should be involved in exercise promotion. © 2017 The Authors Health Expectations Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Petrovic, K.
2015-10-01
Light emitting electron beam generated in a vacuum chamber is used as a medium for visualizing Jupiter's electromagnetic radiation. Dual dipole array antenna is receiving HF radio signals that are next amplified to radiate a strong electromagnetic field capable of influencing the propagation of electron beam in plasma. Installation aims to provide a platform for observing the characteristics of light emitting beam in 3D, as opposed to the experiments with cathode ray tubes in 2-dimensional television screens. Gas giant 'speaking' to us by radio waves bends the light in the tube, allowing us to see and hear the messages of Jupiter - God of light and sky.
Theory of waves incoherently scattered
NASA Technical Reports Server (NTRS)
Bauer, P.
1974-01-01
Electromagnetic waves impinging upon a plasma at frequencies larger than the plasma frequency, suffer weak scattering. The scattering arises from the existence of electron density fluctuations. The received signal corresponds to a particular spatial Fourier component of the fluctuations, the wave vector of which is a function of the wavelength of the radiowave. Wavelengths short with respect to the Debye length of the medium relate to fluctuations due to non-interacting Maxwellian electrons, while larger wavelengths relate to fluctuations due to collective Coulomb interactions. In the latter case, the scattered signal exhibits a spectral distribution which is characteristic of the main properties of the electron and ion gases and, therefore, provides a powerful diagnosis of the state of the ionosphere.
Vehicle drive module having improved terminal design
Beihoff, Bruce C.; Radosevich, Lawrence D.; Phillips, Mark G.; Kehl, Dennis L.; Kaishian, Steven C.; Kannenberg, Daniel G.
2006-04-25
A terminal structure for vehicle drive power electronics circuits reduces the need for a DC bus and thereby the incidence of parasitic inductance. The structure is secured to a support that may receive one or more power electronic circuits. The support may aid in removing heat from the circuits through fluid circulating through the support. The support may form a shield from both external EMI/RFI and from interference generated by operation of the power electronic circuits. Features may be provided to permit and enhance connection of the circuitry to external circuitry, such as by direct contact between the terminal assembly and AC and DC circuit components. Modular units may be assembled that may be coupled to electronic circuitry via plug-in arrangements or through interface with a backplane or similar mounting and interconnecting structures.
Power converter having improved terminal structure
Radosevich, Lawrence D.; Kannenberg, Daniel G.; Phillips, Mark G.; Kaishian, Steven C.
2007-03-06
A terminal structure for power electronics circuits reduces the need for a DC bus and thereby the incidence of parasitic inductance. The structure is secured to a support that may receive one or more power electronic circuits. The support may aid in removing heat from the circuits through fluid circulating through the support. The support may form a shield from both external EMI/RFI and from interference generated by operation of the power electronic circuits. Features may be provided to permit and enhance connection of the circuitry to external circuitry, such as by direct contact between the terminal assembly and AC and DC circuit components. Modular units may be assembled that may be coupled to electronic circuitry via plug-in arrangements or through interface with a backplane or similar mounting and interconnecting structures.
Sujansky, Walter; Wilson, Tom
2015-04-01
This report describes a grant-funded project to explore the use of DIRECT secure messaging for the electronic delivery of laboratory test results to outpatient physicians and electronic health record systems. The project seeks to leverage the inherent attributes of DIRECT secure messaging and electronic provider directories to overcome certain barriers to the delivery of lab test results in the outpatient setting. The described system enables laboratories that generate test results as HL7 messages to deliver these results as structured or unstructured documents attached to DIRECT secure messages. The system automatically analyzes generated HL7 messages and consults an electronic provider directory to determine the appropriate DIRECT address and delivery format for each indicated recipient. The system also enables lab results delivered to providers as structured attachments to be consumed by HL7 interface engines and incorporated into electronic health record systems. Lab results delivered as unstructured attachments may be printed or incorporated into patient records as PDF files. The system receives and logs acknowledgement messages to document the status of each transmitted lab result, and a graphical interface allows searching and review of this logged information. The described system is a fully implemented prototype that has been tested in a laboratory setting. Although this approach is promising, further work is required to pilot test the system in production settings with clinical laboratories and outpatient provider organizations. Copyright © 2015 Elsevier Inc. All rights reserved.
EMSC program manager survey on education of prehospital providers.
Ngo, Thuy L; Belli, Karen; Shah, Manish I
2014-01-01
Although pediatric-specific objectives for the initial education of prehospital providers have been established, uniform implementation of these objectives and guidelines for hours of required pediatric continuing education (CE) for prehospital providers have not been established. To examine the content and number of hours of pediatric-specific education that prehospital providers receive during initial certification and recertification. Second, to identify barriers to implementing specific requirements for pediatric education of prehospital providers. Electronic surveys were sent to 55 EMS for Children (EMSC) State Partnership grantee program managers inquiring about the certification and recertification processes of prehospital providers and barriers to receiving pediatric training in each jurisdiction. We had a 91% response rate for our survey. Specified pediatric education hours exist in more states and territories for recertification (63-67%) than initial certification (41%). Limitations in funding, time, instructors, and accessibility are barriers to enhancing pediatric education. Modifying statewide policies on prehospital education and increasing hands-on training may overcome identified barriers.
77 FR 35691 - Update to Electronic Common Technical Document Module 1
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-14
... Electronic Common Technical Document (eCTD) Module 1, which is used for electronic submission of... they are received with a limit of 350. SUPPLEMENTARY INFORMATION: The eCTD is an International... Research (CBER) have been receiving submissions in the eCTD format since 2003, and the eCTD has been the...
How we give personalised audio feedback after summative OSCEs.
Harrison, Christopher J; Molyneux, Adrian J; Blackwell, Sara; Wass, Valerie J
2015-04-01
Students often receive little feedback after summative objective structured clinical examinations (OSCEs) to enable them to improve their performance. Electronic audio feedback has shown promise in other educational areas. We investigated the feasibility of electronic audio feedback in OSCEs. An electronic OSCE system was designed, comprising (1) an application for iPads allowing examiners to mark in the key consultation skill domains, provide "tick-box" feedback identifying strengths and difficulties, and record voice feedback; (2) a feedback website giving students the opportunity to view/listen in multiple ways to the feedback. Acceptability of the audio feedback was investigated, using focus groups with students and questionnaires with both examiners and students. 87 (95%) students accessed the examiners' audio comments; 83 (90%) found the comments useful and 63 (68%) reported changing the way they perform a skill as a result of the audio feedback. They valued its highly personalised, relevant nature and found it much more useful than written feedback. Eighty-nine per cent of examiners gave audio feedback to all students on their stations. Although many found the method easy, lack of time was a factor. Electronic audio feedback provides timely, personalised feedback to students after a summative OSCE provided enough time is allocated to the process.
Space Weather Activities of IONOLAB Group: IONOLAB-TEC
NASA Astrophysics Data System (ADS)
Arikan, F.; Sezen, U.; Arikan, O.; Ugurlu, O.; Nayir, H.
2009-04-01
Space Weather (SW) is the concept of changing environmental conditions in outer space and affect Earth and its technological systems. SW is a consequence of the solar activities and the coupling of solar energy on Earth's atmosphere due to the Earth's magnetic field. The monitoring and prediction of SW has utmost importance for HF communication, Satellite communication, navigation and guidance systems, Low Earth Orbit (LEO) satellite systems, Space Craft exit and entry into the atmosphere. Ionosphere is the plasma layer of the atmosphere that is ionized by solar radiation and it is a key player of SW. Ionosphere is a temporally and spatially varying, dispersive, anisotropic and inhomogeneous medium that is characterized primarily by its electron density distribution. IONOLAB is a group of researchers of various disciplines, getting together to handle challenges of the Earth's ionosphere. The team has researchers from Hacettepe University and Bilkent University, Department of Electrical and Electronics Engineering and General Command of Mapping of Turkish Army. One of the most important contributions of IONOLAB group is the automated web-based computation service for Total Electron Content (TEC). TEC corresponds to the line integral of electron density distribution on a given path. TEC can also be expressed as the amount of free electrons within 1 m2 cross-sectional area of the cylinder on the ray path. Global Position System (GPS) provides a cost-effective medium for monitoring of ionosphere using the signals recorded by stationary GPS receivers in estimating TEC. IONOLAB group has developed IONOLAB-TEC for reliable and robust estimates for all latitudes and both calm and disturbed days by using RINEX, IONEX and satellite ephemeris data provided from the IGS centers. IONOLAB-TEC consists of a regularized signal estimation algorithm which combines signals from all GPS satellites for a given instant and a given receiver, for a desired time period or for 24 hours, with 30 s time resolution. IONOLAB-TEC values also include the receiver differential code bias (DCB) for each GPS station estimated uniquely by the IONOLAB-BIAS algorithm. The web based computation program is written in JAVA and it is provided both in Turkish and English at www.ionolab.org. The IONOLAB-TEC computation requires no installation or licensing on the client side. The application has a layered design. Developed components are modular that allows possible changes regarding the estimation method can be easily adapted. Same flexibility is also provided for the data access. Also, presentation of estimation data is architected to support different client types. Currently, the user can login to the IONOLAB-TEC web site and choose the desired location and dates on-line for TEC estimation. The carrier phase leveled TEC estimates of IONOLAB-TEC are provided for the chosen station/s and for the chosen day/s along with two-hourly GIM-TEC estimates of IGS centers. The output is provided in the user designated form either in graphs or an excel data sheet. The IONOLAB-TEC provides robust, reliable, and high resolution TEC estimates and provides a medium for comparison of the GIM-TEC values from the IGS centers.
77 FR 46551 - Office of Privacy, Records, and Disclosure; Privacy Act of 1974, as Amended
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-03
... its intent to create the SIGAR system of records titled, SIGAR-11: Social Media Records, and SIGAR-12: Internal Electronic Collaboration Tools. The Social Media system will assist SIGAR by providing new ways to... SIGAR Intranet and social media tools within the Internet. DATES: Comments must be received no later...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-06
... are signing the oath or declaration, the joint inventors must sign the oath or declaration on behalf... be received on or before March 6, 2012. ADDRESSES: Comments should be sent be electronic mail message... Portal Web site ( http://www.regulations.gov ) for additional instructions on providing comments via the...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-15
... against a resting order or quote in the Consolidated Book (i.e., taking liquidity), or, alternatively, a resting electronic order or quote in the Consolidated Book (i.e., posted liquidity) generally receives a..., although not identical because of differing levels of obligations. The proposed rates also provide for...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-29
..., Federal Register notice they may be inspected, between 10 a.m. and 4 p.m., in the FinCEN reading room in...-Filing, which is provided free of charge, offers streamlined BSA information submission; faster routing... suspicious activity report (SAR) was received; Feedback reports to filers; Faster acknowledgement to money...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-19
...: To be assured consideration, comments must be received at one of the addresses provided below, no... submit comments in one of four ways (please choose only one of the ways listed): 1. Electronically. You...-9994 in advance to schedule your arrival with one of our staff members. Comments erroneously mailed to...
Memory-built-in quantum cloning in a hybrid solid-state spin register
Wang, W.-B.; Zu, C.; He, L.; Zhang, W.-G.; Duan, L.-M.
2015-01-01
As a way to circumvent the quantum no-cloning theorem, approximate quantum cloning protocols have received wide attention with remarkable applications. Copying of quantum states to memory qubits provides an important strategy for eavesdropping in quantum cryptography. We report an experiment that realizes cloning of quantum states from an electron spin to a nuclear spin in a hybrid solid-state spin register with near-optimal fidelity. The nuclear spin provides an ideal memory qubit at room temperature, which stores the cloned quantum states for a millisecond under ambient conditions, exceeding the lifetime of the original quantum state carried by the electron spin by orders of magnitude. The realization of a cloning machine with built-in quantum memory provides a key step for application of quantum cloning in quantum information science. PMID:26178617
76 FR 43477 - Debit Card Interchange Fees and Routing
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-20
...The Board is adopting an interim final rule and requesting comment on provisions in Regulation II (Debit Card Interchange Fees and Routing) adopted in accordance with Section 920(a)(5) of the Electronic Fund Transfer Act, which governs adjustments to debit interchange transaction fees for fraud-prevention costs. The provisions allow an issuer to receive an adjustment of 1 cent to its interchange transaction fee if the issuer develops, implements, and updates policies and procedures reasonably designed to identify and prevent fraudulent electronic debit transactions; monitor the incidence of, reimbursements received for, and losses incurred from fraudulent electronic debit transactions; respond appropriately to suspicious electronic debit transactions so as to limit the fraud losses that may occur and prevent the occurrence of future fraudulent electronic debit transactions; and secure debit card and cardholder data. If an issuer meets these standards and wishes to receive the adjustment, it must certify its eligibility to receive the fraud-prevention adjustment to the payment card networks in which the issuer participates.
Zeleznikar, Elizabeth A; Kroehl, Miranda E; Perica, Katharine M; Thompson, Angela M; Trinkley, Katy E
2017-01-01
Barriers exist for patients transitioning from one health-care setting to another, or to home, and health-care systems are falling short of meeting patient needs during this time. Community pharmacist incorporation poses a solution to the current communication breakdown and high rates of medication errors during transitions of care (TOC). The purpose of this study was to determine community pharmacists' involvement in and perceptions of TOC services. Cross-sectional study using electronic surveys nationwide to pharmacists employed by a community pharmacy chain. Of 7236 pharmacists surveyed, 546 (7.5%) responded. Only 33 (6%) pharmacists reported their pharmacy participates in TOC services. Most pharmacists (81.5%) reported receiving discharge medication lists. The most common reported barrier to TOC participation is lack of electronic integration with surrounding hospitals (51.1%). Most pharmacists agreed that (1) it is valuable to receive discharge medication lists (83.3%), (2) receiving discharge medication lists is beneficial for patients' health (89.1%), (3) discharge medication list receipt improves medication safety (88.8%). Most pharmacists reported receiving discharge medication lists and reported discharge medication lists are beneficial, but less than half purposefully used medication lists. To close TOC gaps, health-care providers must collaborate to overcome barriers for successful TOC services.
Sheu, Leslie; Fung, Kelly; Mourad, Michelle; Ranji, Sumant; Wu, Ethel
2015-05-01
Poor communication between hospitalists and outpatient physicians can contribute to adverse events after discharge. Electronic medical records (EMRs) shared by inpatient and outpatient clinicians offer primary care providers (PCPs) better access to information surrounding a patient's hospitalization. However, the PCP experience and subsequent expectations for discharge communication within a shared EMR are unknown. We surveyed PCPs 1 year after a shared EMR was implemented at our institution to assess PCP satisfaction with current discharge communication practices and identify areas for improvement. Seventy-five of 124 (60%) clinicians completed the survey. Although most PCPs reported receiving automated discharge notifications (71%), only 39% felt that notifications plus discharge summaries were adequate for safe transitions of care. PCPs expressed that complex hospitalizations necessitated additional communication via e-mail or telephone; only 31% reported receiving such communication. The content most important in additional communication included medication changes, follow-up actions, and active medical issues. Despite optimized access to information provided by a shared EMR, only 52% of PCPs were satisfied with current discharge communication. PCPs express a continued need for high-touch communication for safe transitions of care. Further standardization of discharge communication practices is necessary. © 2015 Society of Hospital Medicine.
Conlin, Ava Marie S; Bukowinski, Anna T; Gumbs, Gia R
2015-08-26
The National Smallpox Vaccine in Pregnancy Registry (NSVIPR) actively follows women inadvertently vaccinated with smallpox vaccine during or shortly before pregnancy to evaluate their reproductive health outcomes. Approximately 65% of NSVIPR participants also inadvertently received Anthrax Vaccine Adsorbed (AVA) while pregnant, providing a ready opportunity to evaluate pregnancy and infant health outcomes among these women. AVA-exposed pregnancies were ascertained using NSVIPR and electronic healthcare data. Rates of pregnancy loss and infant health outcomes, including major birth defects, were compared between AVA-exposed and AVA-unexposed pregnancies. Analyses included AVA-exposed and AVA-unexposed pregnant women who also received smallpox vaccine 28 days prior to or during pregnancy. Rates of adverse outcomes among the AVA-exposed group were similar to or lower than expected when compared with published reference rates and the AVA-unexposed population. The findings provide reassurance of the safety of AVA when inadvertently received by a relatively young and healthy population during pregnancy. Copyright © 2015 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Crane, Laura; Benachour, Phillip
2013-01-01
The paper describes the analysis of user location and time stamp information automatically logged when students receive and interact with electronic updates from the University's virtual learning environment. The electronic updates are sent to students' mobile devices using RSS feeds. The mobile reception of such information can be received in…
Cryogenic Amplifier Based Receivers at Submillimeter Wavelengths
NASA Technical Reports Server (NTRS)
Chattopadhyay, Goutam; Reck, Theodore and; Schlecht, Erich; Lin, Robert; Deal, William
2012-01-01
The operating frequency of InP high electron mobility transistor (HEMT) based amplifiers has moved well in the submillimeter-wave frequencies over the last couple of years. Working amplifiers with usable gain in waveguide packages has been reported beyond 700 GHz. When cooled cryogenically, they have shown substantial improvement in their noise temperature. This has opened up the real possibility of cryogenic amplifier based heterodyne receivers at submillimeter wavelengths for ground-based, air-borne, and space-based instruments for astrophysics, planetary, and Earth science applications. This paper provides an overview of the science applications at submillimeter wavelengths that will benefit from this technology. It also describes the current state of the InP HEMT based cryogenic amplifier receivers at submillimeter wavelengths.
Comparisons of Measurements and Modeling of Solar Eclipse Effects on VLF Transmissions
NASA Astrophysics Data System (ADS)
Eccles, J. V.; Rice, D. D.; Sojka, J. J.; Marshall, R. A.; Drob, D. P.; Decena, J. C.
2017-12-01
The solar eclipse of 2017 August 21 provides an excellent opportunity to examine Very Low Frequency (VLF) radio signal propagation through the path of the solar eclipse between Navy VLF transmitters and several VLF receivers. The VLF transmitters available for this study radio signal propagation study are NLK in Jim Creek, Washington (24.8 kHz, 192 kW, 48.20N, 121.90W), NML in LaMour, North Dakota (25.2 kHz, 500 kW 46.37N, 93.34W), and NAA in Cutler, Maine (24.0 kHz, 1000 kW, 44.65N, 67.29W). These VLF transmitters provide propagation paths to three VLF receivers at Utah State University (41.75N, 111.76W), Bear Lake Observatory (41.95N, 111.39W), Salt Lake City (40.76N, 111.89W) and one receiver in Boulder, Colorado (40.02N, 105.27W). The solar eclipse shadow will cross all propagations paths during the day and will modify the D region electron density within the solar shadow. The week prior to the solar eclipse will be used to generate a diurnal baseline of VLF single strength for each transmitter-receiver pair. These will be compared to the day of the solar eclipse to identify VLF propagation differences through the solar eclipse shawdow. Additionally, the electron density effects of the week prior and of the solar eclipse day will be modeled using the Data-Driven D Region (DDDR) model [Eccles et al., 2005] with a detailed eclipse solar flux mask. The Long-Wave Propagation Code and the HASEL RF ray-tracing code will be used to generate VLF signal strength for each measured propagation path through the days prior and the solar eclipse day. Model-measurement comparisons will be presented and the D region electron density effects of the solar eclipse will be examined. The DDDR is a time-dependent D region model, which makes it very suitable for the solar eclipse effects on the electron density for the altitude range of 36 to 130 km. Eccles J. V., R. D. Hunsucker, D. Rice, J. J. Sojka (2005), Space weather effects on midlatitude HF propagation paths: Observations and a data-driven D region model, Space Weather, 3, S01002, doi:10.1029/2004SW000094.
Casey, Michelle M; Moscovice, Ira; McCullough, Jeffrey
2014-01-01
To examine the role of Regional Extension Centers (RECs) in helping rural physician practices adopt electronic health records (EHRs) and achieve meaningful use. Using data from the Office of the National Coordinator for Health Information Technology, we conducted a county-level regression analysis using ordinary least squares to better understand rural-urban differences in REC participation, EHR implementation, and meaningful use, controlling for counties' economic conditions. We prepared case studies of 2 RECs that are serving a large number of rural practices, based on interviews with key individuals at the RECs, their partner organizations, and rural primary care practices that received assistance from the RECs. RECs are largely achieving their objective of targeting providers in communities that face barriers to EHRs. REC participants are disproportionately rural and more likely to come from high poverty and low employment communities. The case study RECs had long-standing relationships with rural providers, as well as extensive staff expertise in quality improvement and EHR implementation, and employed a variety of strategies to successfully assist rural providers. Rural providers report that REC assistance was invaluable in helping them implement EHRs and achieve meaningful use status. Modifying the criteria for Medicare and Medicaid EHR incentives could help additional rural providers pay for EHRs. REC federal funding is scheduled to end in 2014, but practices that have not yet adopted EHRs may need significant, ongoing assistance to receive meaningful use. © 2013 National Rural Health Association.
Photonic compressed sensing nyquist folding receiver
2017-09-01
filter . Two independent photonic receiver architectures are designed and analyzed over the course of this research. Both receiver designs are...undersamples the signals using an opti- cal modulator configuration at 1550 nm and collects the detected samples in a low pass interpolation filter ...Electronic Intelligence EW Electronic Warfare FM Frequency Modulated LNA Low Noise Amplifier LPF Low Pass Filter MZI Mach-Zehnder Interferometer NYFR Nyquist
Secondary Electron Emission Yields
NASA Technical Reports Server (NTRS)
Krainsky, I.; Lundin, W.; Gordon, W. L.; Hoffman, R. W.
1981-01-01
The secondary electron emission (SEE) characteristics for a variety of spacecraft materials were determined under UHV conditions using a commercial double pass CMA which permits sequential Auger electron electron spectroscopic analysis of the surface. The transparent conductive coating indium tin oxide (ITO) was examined on Kapton and borosilicate glass and indium oxide on FED Teflon. The total SEE coefficient ranges from 2.5 to 2.6 on as-received surfaces and from 1.5 to 1.6 on Ar(+) sputtered surfaces with 5 nm removed. A cylindrical sample carousel provides normal incidence of the primary beam as well as a multiple Faraday cup measurement of the approximately nA beam currents. Total and true secondary yields are obtained from target current measurements with biasing of the carousel. A primary beam pulsed mode to reduce electron beam dosage and minimize charging of insulating coatings was applied to Mg/F2 coated solar cell covers. Electron beam effects on ITO were found quite important at the current densities necessary to do Auger studies.
Interplay of hot electrons from localized and propagating plasmons.
Hoang, Chung V; Hayashi, Koki; Ito, Yasuo; Gorai, Naoki; Allison, Giles; Shi, Xu; Sun, Quan; Cheng, Zhenzhou; Ueno, Kosei; Goda, Keisuke; Misawa, Hiroaki
2017-10-03
Plasmon-induced hot-electron generation has recently received considerable interest and has been studied to develop novel applications in optoelectronics, photovoltaics and green chemistry. Such hot electrons are typically generated from either localized plasmons in metal nanoparticles or propagating plasmons in patterned metal nanostructures. Here we simultaneously generate these heterogeneous plasmon-induced hot electrons and exploit their cooperative interplay in a single metal-semiconductor device to demonstrate, as an example, wavelength-controlled polarity-switchable photoconductivity. Specifically, the dual-plasmon device produces a net photocurrent whose polarity is determined by the balance in population and directionality between the hot electrons from localized and propagating plasmons. The current responsivity and polarity-switching wavelength of the device can be varied over the entire visible spectrum by tailoring the hot-electron interplay in various ways. This phenomenon may provide flexibility to manipulate the electrical output from light-matter interaction and offer opportunities for biosensors, long-distance communications, and photoconversion applications.Plasmon-induced hot electrons have potential applications spanning photodetection and photocatalysis. Here, Hoang et al. study the interplay between hot electrons generated by localized and propagating plasmons, and demonstrate wavelength-controlled polarity-switchable photoconductivity.
National aerospace meeting of the Institute of Navigation
NASA Astrophysics Data System (ADS)
Fell, Patrick
The program for this year's aerospace meeting of The Institute of Navigation addressed developments in the evolving Global Positioning System (GPS) of navigation satellites, inertial navigation systems, and other electronic navigation systems and their applications. Also included in the program were a limited number of papers addressing the geodetic use of the GPS system.The Global Positioning System is a constellation of 18 navigation satellites being developed by the Department of Defense to provide instantaneous worldwide navigation. The system will support a multitude of military applications. The first paper by Jacobson reviewed the engineering development of GPS navigation receivers stressing the use of common hardware and software modules. A later paper by Ould described the mechanization of a digital receiver for GPS applications designed for faster acquisition of the spread spectrum satellite transmissions than analog receivers. The paper by Brady discussed the worldwide coverage that is provided by the limited number of satellites that will constitute the GPS constellation through 1983. The capability provided by the satellites presently on orbit would support a variety of experiments at almost any location. Tables of multiple satellite availability are provided for numerous worldwide locations. For civil aviation applications, Vogel addressed the satellite geometry considerations for low cost GPS user equipment, Esposito described the Federal Aviation Administration acceptance tests of a GPS navigation receiver, and Hopkins discussed the design and capability of an integrated GPS strapdown attitude and heading reference system for avionics.
NASA Technical Reports Server (NTRS)
Youngquist, Robert C. (Inventor); Moerk, Steven (Inventor)
1999-01-01
An imaging system is described which can be used to either passively search for sources of ultrasonics or as an active phase imaging system. which can image fires. gas leaks, or air temperature gradients. This system uses an array of ultrasonic receivers coupled to an ultrasound collector or lens to provide an electronic image of the ultrasound intensity in a selected angular region of space. A system is described which includes a video camera to provide a visual reference to a region being examined for ultrasonic signals.
Jump, Robin L.; Banks, Richard; Wilson, Brigid; Montpetite, Michelle M.; Carter, Rebecca; Phillips, Susan; Perez, Federico
2015-01-01
We developed a “virtual clinic” to improve pneumococcal vaccination among asplenic adults. Using an electronic medical record, we identified patients, assessed their vaccination status, entered orders, and notified patients and providers. Within 180 days, 38 of 76 patients (50%) received a pneumococcal vaccination. A virtual clinic may optimize vaccinations among high-risk patients. PMID:26668815
Hiratsuka, Vanessa Y; Avey, Jaedon P; Trinidad, Susan B; Beans, Julie A; Robinson, Renee F
2015-01-01
American Indian (AI) and Alaska Native (AN) communities confront some of the highest rates of tobacco use and its sequelae. This formative research project sought to identify the perspectives of 41 stakeholders (community members receiving care within the healthcare system, primary care providers, and tribal healthcare system leaders) surrounding the use of pharmacogenetics toward tobacco cessation treatment in the setting of an AI/AN owned and operated health system in south central Alaska. Interviews were held with 20 adult AI/AN current and former tobacco users, 12 healthcare providers, and 9 tribal leaders. An emergent theme from data analysis was that current tobacco screening and cessation efforts lack information on electronic cigarette (e-cigarette) use. Perceptions of the use of e-cigarettes role in tobacco cessation varied. Preventive screening for tobacco use and clinical cessation counseling should address e-cigarette use. Healthcare provider tobacco cessation messaging should similarly address e-cigarettes.
NASA Technical Reports Server (NTRS)
Lanyi, Gabor E.; Roth, Titus
1988-01-01
Total ionospheric electron contents (TEC) were measured by global positioning system (GPS) dual-frequency receivers developed by the Jet Propulsion Laboratory. The measurements included P-code (precise ranging code) and carrier phase data for six GPS satellites during multiple five-hour observing sessions. A set of these GPS TEC measurements were mapped from the GPS lines of sight to the line of sight of a Faraday beacon satellite by statistically fitting the TEC data to a simple model of the ionosphere. The mapped GPS TEC values were compared with the Faraday rotation measurements. Because GPS transmitter offsets are different for each satellite and because some GPS receiver offsets were uncalibrated, the sums of the satellite and receiver offsets were estimated simultaneously with the TEC in a least squares procedure. The accuracy of this estimation procedure is evaluated indicating that the error of the GPS-determined line of sight TEC can be at or below 1 x 10 to the 16th el/sq cm. Consequently, the current level of accuracy is comparable to the Faraday rotation technique; however, GPS provides superior sky coverage.
Clayton, Zachary S; Wilds, Gabriel P; Mangum, Joshua E; Hocker, Austin D; Dawson, Sierra M
2016-09-01
We investigated how students performed on weekly two-page laboratory reports based on whether the grading rubric was provided to the student electronically or in paper form and the inclusion of one- to two-sentence targeted comments. Subjects were registered for a 289-student, third-year human physiology class with laboratory and were randomized into four groups related to rubric delivery and targeted comments. All students received feedback via the same detailed grading rubric. At the end of the term, subjects provided consent and a self-assessment of their rubric viewing rate and preferences. There were no differences in laboratory report scores between groups (P = 0.86), although scores did improve over time (P < 0.01). Students receiving targeted comments self-reported viewing their rubric more often than students that received no comments (P = 0.02), but the viewing rate was independent of the rubric delivery method (P = 0.15). Subjects with high rubric viewing rates did not have higher laboratory report grades than subjects with low viewing rates (P = 0.64). When asked about their preference for the future, 43% of respondents preferred the same method again (electronic or paper rubric) and 25% had no preference. We conclude that although student laboratory report grades improved over time, the rate and degree of improvement were not related to rubric delivery method or to the inclusion of targeted comments. Copyright © 2016 The American Physiological Society.
Bae, Woo Kyun; Kwon, Jihyun; Lee, Hyun Woo; Lee, Sang-Cheol; Song, Eun-Kee; Shim, Hyeok; Ryu, Keun Ho; Song, Jemin; Seo, Sungbo; Yang, Yaewon; Park, Jong-Hyock; Lee, Ki Hyeong; Han, Hye Sook
2018-05-07
There is growing interest in integrating electronic patient-reported outcome (PRO) measures into routine oncology practice for symptom monitoring. Here, we evaluated the feasibility and accessibility of electronic PRO measures using a smartphone (PRO-SMART) for cancer patients receiving routine chemotherapy. The proposed PRO-SMART application obtains daily personal health record (PHR) data from cancer patients via a smartphone. An analysis report of cumulative PHR data is provided to the clinician in a format suitable for upload to electronic medical records (EMRs). Cancer outpatients who had received at least two cycles of chemotherapy and who were scheduled for two more cycles were enrolled. Between February 2015 and December 2016, 111 patients were screened and 101 of these were included. One-hundred patients used PRO-SMART at least once and were included in the final analysis (90.1% overall accessibility among all screened patients). The number of symptomatic adverse events (AEs) related to chemotherapy recorded in EMRs (mean ± standard deviation [SD]) increased from 0.92 ± 0.80 to 2.26 ± 1.80 (P < 0.001), and grading of AEs increased from 0.81 ± 0.69 to 1.00 ± 0.62 (P = 0.029). After using PRO-SMART, the numeric rating scale for pain (mean ± SD) increased from 0.20 ± 0.72 to 0.99 ± 1.55 (P < 0.001). A patient-reported questionnaire revealed that 64.2% of patients found it useful and 83% found it easy to use. This study suggests that the proposed PRO-SMART is feasible and accessible for assessment of symptomatic AEs in cancer patients receiving chemotherapy for a prospective randomized trial.
Limiting ventilator-induced lung injury through individual electronic medical record surveillance.
Herasevich, Vitaly; Tsapenko, Mykola; Kojicic, Marija; Ahmed, Adil; Kashyap, Rachul; Venkata, Chakradhar; Shahjehan, Khurram; Thakur, Sweta J; Pickering, Brian W; Zhang, Jiajie; Hubmayr, Rolf D; Gajic, Ognjen
2011-01-01
To improve the safety of ventilator care and decrease the risk of ventilator-induced lung injury, we designed and tested an electronic algorithm that incorporates patient characteristics and ventilator settings, allowing near-real-time notification of bedside providers about potentially injurious ventilator settings. Electronic medical records of consecutive patients who received invasive ventilation were screened in three Mayo Clinic Rochester intensive care units. The computer system alerted bedside providers via the text paging notification about potentially injurious ventilator settings. Alert criteria included a Pao2/Fio2 ratio of <300 mm Hg, free text search for the words "edema" or "bilateral + infiltrates" on the chest radiograph report, a tidal volume of >8 mL/kg predicted body weight (based on patient gender and height), a plateau pressure of >30 cm H2O, and a peak airway pressure of >35 cm H2O. Respiratory therapists answered a brief online satisfaction survey. Ventilator-induced lung injury risk was compared before and after the introduction of ventilator-induced lung injury alert. The prevalence of acute lung injury was 42% (n = 490) among 1,159 patients receiving >24 hrs of invasive ventilation. The system sent 111 alerts for 80 patients, with a positive predictive value of 59%. The exposure to potentially injurious ventilation decreased after the intervention from 40.6 ± 74.6 hrs to 26.9 ± 77.3 hrs (p = .004). Electronic medical record surveillance of mechanically ventilated patients accurately detects potentially injurious ventilator settings and is able to influence bedside practice at moderate costs. Its implementation is associated with decreased patient exposure to potentially injurious mechanical ventilation settings.
Optical link by using optical wiring method for reducing EMI
NASA Astrophysics Data System (ADS)
Cho, In-Kui; Kwon, Jong-Hwa; Choi, Sung-Woong; Bondarik, Alexander; Yun, Je-Hoon; Kim, Chang-Joo; Ahn, Seung-Beom; Jeong, Myung-Yung; Park, Hyo Hoon
2008-12-01
A practical optical link system was prepared with a transmitter (Tx) and receiver (Rx) for reducing EMI (electromagnetic interference). The optical TRx module consisted of a metal optical bench, a module printed circuit board (PCB), a driver/receiver IC, a VCSEL/PD array, and an optical link block composed of plastic optical fiber (POF). For the optical interconnection between the light-sources and detectors, an optical wiring method has been proposed to enable easy assembly. The key benefit of fiber optic link is the absence of electromagnetic interference (EMI) noise creation and susceptibility. This paper provides a method for optical interconnection between an optical Tx and an optical Rx, comprising the following steps: (i) forming a light source device, an optical detection device, and an optical transmission unit on a substrate (metal optical bench (MOB)); (ii) preparing a flexible optical transmission-connection medium (optical wiring link) to optically connect the light source device formed on the substrate with the optical detection device; and (iii) directly connecting one end of the surface-finished optical transmission connection medium with the light source device and the other end with the optical detection device. Electronic interconnections have uniquely electronic problems such as EMI, shorting, and ground loops. Since these problems only arise during transduction (electronics-to-optics or opticsto- electronics), the purely optical part and optical link(interconnection) is free of these problems. 1 An optical link system constructed with TRx modules was fabricated and the optical characteristics about data links and EMI levels were measured. The results clearly demonstrate that the use of an optical wiring method can provide robust and cost-effective assembly for reducing EMI of inter-chip interconnect. We successfully achieved a 4.5 Gb/s data transmission rate without EMI problems.
Kubota, Y; Leung, E; Vincent, S R
1992-01-01
The ultrastructure of choline acetyltransferase (ChAT)-immunoreactive neurons in the laterodorsal tegmental nucleus (TLD) of the rat was investigated by immunohistochemical techniques. The immunoreactive neurons were medium to large in size, with a few elongated dendrites, contained well-developed cytoplasm, and a nucleus with deep infoldings. They received many nonimmunoreactive, mostly asymmetric synaptic inputs on their soma and dendrites. ChAT-immunoreactive, usually myelinated, axons were occasionally seen in TLD. Only one immunoreactive axon terminal was observed within TLD, and it made synaptic contact with a nonimmunoreactive neuronal perikaryon. The synaptic interactions between ChAT-immunoreactive neurons and tyrosine hydroxylase (TH)-immunoreactive fibers in the TLD were investigated with a double immunohistochemical staining method. ChAT-immunoreactivity detected with a beta-galactosidase method was light blue-green in the light microscope and formed dot-like electron dense particles at the electron microscopic level. TH-immunoreactivity, visualized with a nickel-enhanced immunoperoxidase method, was dark blue-black in the light microscope and diffusely opaque in the electron microscope. Therefore, the difference between these two kinds of immunoreactivity could be quite easily distinguished at both light and electron microscopic levels. In the light microscope, TH-positive fibers were often closely apposed to ChAT-immunoreactive cell bodies and dendrites in TLD. In the electron microscope, the cell soma and proximal dendrites of ChAT-immunoreactive neurons received synaptic contacts from TH-immunoreactive axon terminals. These results provide a morphological basis for catecholaminergic regulation of the cholinergic reticular system.
NASA Astrophysics Data System (ADS)
Wang, Sicheng; Huang, Sixun; Xiang, Jie; Fang, Hanxian; Feng, Jian; Wang, Yu
2016-12-01
Ionospheric tomography is based on the observed slant total electron content (sTEC) along different satellite-receiver rays to reconstruct the three-dimensional electron density distributions. Due to incomplete measurements provided by the satellite-receiver geometry, it is a typical ill-posed problem, and how to overcome the ill-posedness is still a crucial content of research. In this paper, Tikhonov regularization method is used and the model function approach is applied to determine the optimal regularization parameter. This algorithm not only balances the weights between sTEC observations and background electron density field but also converges globally and rapidly. The background error covariance is given by multiplying background model variance and location-dependent spatial correlation, and the correlation model is developed by using sample statistics from an ensemble of the International Reference Ionosphere 2012 (IRI2012) model outputs. The Global Navigation Satellite System (GNSS) observations in China are used to present the reconstruction results, and measurements from two ionosondes are used to make independent validations. Both the test cases using artificial sTEC observations and actual GNSS sTEC measurements show that the regularization method can effectively improve the background model outputs.
Messages discriminated from the media about illicit drugs.
Patterson, S J
1994-01-01
The electronic media have been an instrumental tool in the most recent efforts to address the issue of illicit drug abuse in the United States. Messages about illicit drugs appear in three places in the media: advertising content, news content, and entertainment content. Many studies have documented the amount and types of messages that appear on the electronic media, but few have asked the audience how they interpret these messages. The purpose of this study is to investigate how much and what type of information college students receive from the media about drugs. Interviews were conducted with 228 students using the message discrimination protocol. The messages were then content analyzed into theme areas. Results indicate the majority of messages discriminated from advertising content were fear appeals; that the majority of messages discriminated from news content documented the enforcement efforts in the war on drugs; and that messages about drugs in entertainment content were more likely to provide clear accurate information about drugs than the other two content sources. The results are discussed in terms of the audience receiving fear and fight messages from the electronic media rather than clear, accurate information necessary to make informed decisions about drugs.
Apparatus and method for imaging metallic objects using an array of giant magnetoresistive sensors
Chaiken, Alison
2000-01-01
A portable, low-power, metallic object detector and method for providing an image of a detected metallic object. In one embodiment, the present portable low-power metallic object detector an array of giant magnetoresistive (GMR) sensors. The array of GMR sensors is adapted for detecting the presence of and compiling image data of a metallic object. In the embodiment, the array of GMR sensors is arranged in a checkerboard configuration such that axes of sensitivity of alternate GMR sensors are orthogonally oriented. An electronics portion is coupled to the array of GMR sensors. The electronics portion is adapted to receive and process the image data of the metallic object compiled by the array of GMR sensors. The embodiment also includes a display unit which is coupled to the electronics portion. The display unit is adapted to display a graphical representation of the metallic object detected by the array of GMR sensors. In so doing, a graphical representation of the detected metallic object is provided.
E-cigarette use in patients receiving home oxygen therapy.
Lacasse, Yves; Légaré, Martin; Maltais, François
2015-01-01
Current smokers who are prescribed home oxygen may not benefit from the therapy. In addition to being an obvious fire hazard, there is some evidence that the physiological mechanisms by which home oxygen is believed to operate are inhibited by smoking. Although their effectiveness is yet to be demonstrated, electronic cigarettes (e-cigarettes) are often regarded as an aid to smoking cessation. However, several burn accidents in e-cigarette smokers receiving home oxygen therapy have also been reported, leading Health Canada to release a warning of fire risk to oxygen therapy patients from e-cigarettes. It is the authors' position that patients receiving oxygen should definitely not use e-cigarettes. The authors provide suggestions for addressing the delicate issue of home oxygen therapy in current cigarette and⁄or e-cigarette smokers.
Ultrasonic imaging using optoelectronic transmitters.
Emery, C D; Casey, H C; Smith, S W
1998-04-01
Conventional ultrasound scanners utilize electronic transmitters and receivers at the scanner with a separate coaxial cable connected to each transducer element in the handle. The number of transducer elements determines the size and weight of the transducer cable assembly that connects the imaging array to the scanner. 2-D arrays that allow new imaging modalities to be introduced significantly increase the channel count making the transducer cable assembly more difficult to handle. Therefore, reducing the size and increasing the flexibility of the transducer cable assembly is a concern. Fiber optics can be used to transmit signals optically and has distinct advantages over standard coaxial cable to increase flexibility and decrease the weight of the transducer cable for larger channel numbers. The use of fiber optics to connect the array and the scanner entails the use of optoelectronics such as detectors and laser diodes to send and receive signals. In transmit, optoelectronics would have to be designed to produce high-voltage wide-bandwidth pulses across the transducer element. In this paper, we describe a 48 channel ultrasound system having 16 optoelectronic transmitters and 32 conventional electronic receivers. We investigated both silicon avalanche photodiodes (APD's) and GaAs lateral photoconductive semiconductor switches (PCSS's) for producing the transmit pulses. A Siemens SI-1200 scanner and a 2.25 MHz linear array were used to compare the optoelectronic system to a conventional electronic transmit system. Transmit signal results and images in tissue mimicking of cysts and tumors are provided for comparison.
Watnick, Caroline S; Binns, Helen J; Greenberg, Robert S
2015-03-01
To examine effectiveness of an intervention promoting vitamin D supplementation in hospitalized breastfed infants. Our urban tertiary care hospital instituted a 2-part intervention: brief education for providers on vitamin D guidelines and insertion of an opt-in order for vitamin D supplements into electronic admission order sets. Data downloads on admissions of patients aged <1 year were obtained. We excluded those not breastfed, with a dietary restriction, or admitted to intensive care. Intervention effects were compared from 6 months postintervention to the 6 same months 1 year earlier. We applied χ2 and logistic regression, including the patient as a random effect to adjust for repeated admissions. Data on 471 exclusively or partially breastfed admissions (441 infants) were analyzed (221 preintervention, 250 postintervention). Admission characteristics did not differ by period: 55.0% boys; 40.6% Medicaid; 63.7% hospitalized ≤2 days; 72.0% on a general medical service; 16.6% received nutritionist consultation. In-hospital vitamin D prescribing rates significantly increased postintervention (19.5% vs 44.4%; P<.001). Postintervention admissions were more than twice as likely to receive vitamin D supplementation (adjusted odds ratio 2.3, 95% confidence interval 1.6-3.2). Other associated factors included vitamin D as a medication used before admission (adjusted odds ratio 14.3, 95% confidence interval 4.9-41.6), nutritionist consultation during admission, hospitalization≥3 days, and admission to a general medical service. Prescribing of vitamin D at discharge increased significantly (9.0% vs 19.6%; P<.001). Medical provider education and modification of electronic ordering templates significantly increased use of vitamin D supplementation in hospitalized breastfed infants. Copyright © 2015 by the American Academy of Pediatrics.
Ishibashi, Masaaki; Ishii, Masakazu; Nagano, Miku; Kiuchi, Yuji; Iwamoto, Sanju
2018-01-01
Previous reports suggested that sharing outpatient information during chemotherapy is very important for managing pharmaceutical usage between community pharmacies and hospitals. We herein examined using a questionnaire survey whether pharmaceutical management for outpatient chemotherapy is desired by community and hospital pharmacists. The response rates were 44.3% (133/300) for pharmacists in community pharmacies and 53.7% (161/300) for pharmacists in hospitals. Prescriptions for outpatients during chemotherapy were issued at 88.2% of the hospitals. Currently, 28.9% of hospital pharmacists rarely provide pharmaceutical care, such as patient guidance and adverse effect monitoring, for outpatients receiving oral chemotherapy. Furthermore, whereas 93.7% of hospital pharmacists conducted prescription audits based on the chemotherapy regimen, audits were only performed by 14.8% of community pharmacists. Thus, outpatients, particularly those on oral regimens, were unable to receive safe pharmaceutical care during chemotherapy. Community pharmacists suggested that hospital pharmacists should use "medication notebooks" and disclose prescription information when providing clinical information to community pharmacists. They also suggested sending clinical information to hospital pharmacists by fax. On the other hand, hospital pharmacists suggested the use of "medication notebooks" and electronic medical records when providing clinical information to community pharmacists. In addition, they suggested for community pharmacists to use electronic medical records when providing clinical information to hospital pharmacists. As there may be differences in opinion between community and hospital pharmacists, mutual preliminary communication is important for successful outpatient chemotherapy.
Electronic properties of two inequivalent surfaces in MoTe2 studied by quasi-particle interference
NASA Astrophysics Data System (ADS)
Iaia, Davide; Shichao, Yan; Madhavan, Vidya
MoTe2 has received renewed interest due to its topological properties. At a temperature below 250 K, MoTe2 is a type II Weyl semimetal hosting three-dimensional (3D) linearly dispersing states with well defined chirality. Nodes in this 3D dispersion are called Weyl points. Weyl points of opposite chirality are expected to be connected by topologically protected Fermi arcs. In this talk we discuss low temperature scanning tunneling microscopy studies of the electronic structure of MoTe2. The electronic properties are studied using quasi-particle interference technique which allows us to resolve Fermi arcs features and to clearly distinguish between two inequivalent MoTe2 surfaces. Our results provide important contributions to further our understanding of the electronic properties of this new and exotic class of materials. National Science Foundation (NSF).
NASA Technical Reports Server (NTRS)
Paul, M. P.
1982-01-01
Measurement of integrated columnar electron content and total electron content for the local ionosphere and the overlying protonosphere via Faraday rotation and group delay techniques has proven very useful. A field station was established having the geographic location of 31.5 deg N latitude and 91.06 deg W longitude to accomplish these objectives. A polarimeter receiving system was set up in the beginning to measure the Faraday rotation of 137.35 MHz radio signal from geostationary satellite ATS 3 to yield the integrated columnar electron content of the local ionosphere. The measurement was continued regularly, and the analysis of the data thus collected provided a synopsis of the statistical variation of the ionosphere along with the transient variations that occurred during the periods of geomagnetic and other disturbances.
Post, R.F.
1958-11-11
An electronic computer circuit is described for producing an output voltage proportional to the product or quotient of tbe voltages of a pair of input signals. ln essence, the disclosed invention provides a computer having two channels adapted to receive separate input signals and each having amplifiers with like fixed amplification factors and like negatlve feedback amplifiers. One of the channels receives a constant signal for comparison purposes, whereby a difference signal is produced to control the amplification factors of the variable feedback amplifiers. The output of the other channel is thereby proportional to the product or quotient of input signals depending upon the relation of input to fixed signals in the first mentioned channel.
Klein, Dawn M; Pham, Kassi; Samy, Leila; Bluth, Adam; Nazi, Kim M; Witry, Matthew; Klutts, J Stacey; Grant, Kathleen M; Gundlapalli, Adi V; Kochersberger, Gary; Pfeiffer, Laurie; Romero, Sergio; Vetter, Brian; Turvey, Carolyn L
2017-04-01
Information continuity is critical to person-centered care when patients receive care from multiple healthcare systems. Patients can access their electronic health record data through patient portals to facilitate information exchange. This pilot was developed to improve care continuity for rural Veterans by (1) promoting the use of the Department of Veterans Affairs (VA) patient portal to share health information with non-VA providers, and (2) evaluating the impact of health information sharing at a community appointment. Veterans from nine VA healthcare systems were trained to access and share their VA Continuity of Care Document (CCD) with their non-VA providers. Patients and non-VA providers completed surveys on their experiences. Participants (n = 620) were primarily older, white, and Vietnam era Veterans. After training, 78% reported the CCD would help them be more involved in their healthcare and 86% planned to share it regularly with non-VA providers. Veterans (n = 256) then attended 277 community appointments. Provider responses from these appointments (n = 133) indicated they were confident in the accuracy of the information (97%) and wanted to continue to receive the CCD (96%). Ninety percent of providers reported the CCD improved their ability to have an accurate medication list and helped them make medication treatment decisions. Fifty percent reported they did not order a laboratory test or another procedure because of information available in the CCD. This pilot demonstrates feasibility and value of patient access to a CCD to facilitate information sharing between VA and non-VA providers. Outreach and targeted education are needed to promote consumer-mediated health information exchange.
Interception of LPI radar signals
NASA Astrophysics Data System (ADS)
Lee, Jim P.
1991-11-01
Most current radars are designed to transmit short duration pulses with relatively high peak power. These radars can be detected easily by the use of relatively modest EW intercept receivers. Three radar functions (search, anti-ship missile (ASM) seeker, and navigation) are examined to evaluate the effectiveness of potential low probability of intercept (LPI) techniques, such as waveform coding, antenna profile control, and power management that a radar may employ against current Electronic Warfare (EW) receivers. The general conclusion is that it is possible to design a LPI radar which is effective against current intercept EW receivers. LPI operation is most easily achieved at close ranges and against a target with a large radar cross section. The general system sensitivity requirement for the detection of current and projected LPI radars is found to be on the order of -100 dBmi which cannot be met by current EW receivers. Finally, three potential LPI receiver architectures, using channelized, superhet, and acousto-optic receivers with narrow RF and video bandwidths are discussed. They have shown some potential in terms of providing the sensitivity and capability in an environment where both conventional and LPI signals are present.
Cross, Dori A; Adler-Milstein, Julia
2017-01-01
Electronic health information exchange (HIE) is expected to help improve care transitions from hospitals to long-term care (LTC) facilities. We know little about the prevalence of hospital LTC HIE in the United States and what contextual factors may motivate or constrain this activity. Cross-sectional analysis of U.S. acute-care hospitals responding to the 2014 AHA IT Supplement survey and with available readmissions data (n = 1,991). We conducted multivariate logistic regression to explore the relationship between hospital LTC HIE and selected IT and policy characteristics. Over half of the hospitals in our study (57.2%) reported engaging in some form of HIE with LTC providers: 33.9% send-only, 0.5% receive-only, and 22.8% send and receive. Hospitals that engaged in some form of LTC HIE were more likely than those that did not engage to have attested to meaningful use (odds ratio [OR], 1.87; P = .01 for stage 1 and OR, 2.05; P < .01 for stage 2), participate in a regional HIE effort (OR, 1.34; P = .021), and exchange information electronically with other hospitals or ambulatory providers (OR, 4.54; P < .01). Organizational affiliation with a skilled nursing facility (OR, 1.29; P = .041) and higher 30-day readmission rates (OR, 1.19; P = .016) were also associated with LTC HIE, but not accountable care organization nor bundled payment participation. As payment to LTC providers and hospitals increasingly emphasizes total patient care and paying for value, those leading these organizations have new incentives to pursue collaborative relationships. Hospitals appear to be investing in electronic information exchange with LTCs as part of a general strategy to adopt EHRs and engage in HIE, but also potentially to strengthen ties to LTC providers and to reduce readmissions. To achieve widespread connectivity, continued focus on adoption of related health IT infrastructure and greater emphasis on aligning incentives for hospital-LTC care transitions would be valuable. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.
Development and evaluation of an electronic drug and therapeutics bulletin.
Alderman, Christopher P
2002-10-01
To describe the development, implementation, and initial evaluation of a paperless drug and therapeutics bulletin that is distributed by electronic mail from the pharmacy department of an Australian teaching hospital. A standardized format for the bulletin was designed and approved in February 2001. The aim of the bulletin is to facilitate the timely dissemination of concise, factual information about issues of current interest in therapeutics, drug safety, and the cost-effective use of medicines. A simple and attractive graphic design was chosen, and the hospital's clinical pharmacists and drug information staff developed an initial bank of content during the period immediately preceding the launch. The bulletin is presented as a 1-page, read-only file in Word for Windows format and was initially distributed by electronic mail to all users of the hospital's computerized communication network. As the popularity of the bulletin increased, healthcare practitioners from outside of the hospital began to request permission for inclusion on the circulation list, and the content was frequently forwarded by E-mail to workers in other hospitals and community-based settings. The bulletin is now distributed to pharmacists around Australia via 2 separate moderated discussion lists, one of which provides an archive site for previous editions. Healthcare workers in Singapore, the US, Canada, and New Zealand also receive the bulletin, which is now also abstracted by a major Australian pharmacy journal. A readership survey (also electronically distributed) was used to seek feedback after the publication of the first 12 editions. Readers indicated a high level of satisfaction with the content, format, and frequency of distribution of the materials. Although the concept and execution of this project was relatively simple, an extensive literature review did not reveal any previously published reports describing this type of approach to the distribution of a pharmacy bulletin. The development and implementation of the electronic drug and therapeutics bulletin has provided an opportunity to use modern communication technology to promote safe and effective medication use and appears to have been well received.
Micro- and Nano-Scale Electrically Driven Two-Phase Thermal Management
NASA Technical Reports Server (NTRS)
Didion, Jeffrey R.
2016-01-01
This presentation discusses ground based proof of concept hardware under development at NASA GSFC to address high heat flux thermal management in silicon substrates. The goal is to develop proof of concept hardware for space flight validation. The space flight hardware will provide gravity insensitive thermal management for electronics applications such as transmit receive modules that are severely limited by thermal concerns.
ERIC Educational Resources Information Center
Bourelle, Tiffany; Bourelle, Andrew
2015-01-01
With distance education on the rise, a new program at the University of New Mexico provides an innovative way to teach first-year composition in a fully online format. The program, called eComp (short for Electronic Composition), insists that instructors receive formal and educational training before working in the model. In addition, the…
ERIC Educational Resources Information Center
Hepburn, Mary A., Ed.
Fourteen conference papers dealing with the effects of electronic information technology on social studies education are provided. Microcomputers received most of the attention, followed by satellite telecommunications, as the conference participants examined implications for student learning styles, student knowledge and attitudes, teacher…
Development of Advanced Spacecraft Thermal Subsystems
NASA Technical Reports Server (NTRS)
Didion, Jeffrey R.
2016-01-01
This presentation discusses ground based proof of concept hardware under development at NASA GSFC to address high heat flux thermal management in silicon substrates and embedded thermal management systems. The goal is to develop proof of concept hardware for space flight validation. The space flight hardware will provide gravity insensitive thermal management for electronics applications such as transmit/receive modules that are severely limited by thermal concerns.
Electrochemical sensor/detector system and method
Glass, Robert S.; Perone, Sam P.; Ciarlo, Dino R.; Kimmons, James F.
1992-01-01
An electrochemical detection system is described comprising in combination: (a) a multielement, microelectrode array detector containing means for acquiring a plurality of signals; (b) electronic means for receiving said signals and converting said signals into a readout or display providing information with respect to the nature and concentration of elements present in a solution being tested. Also described is the means of making the above described microelectrode detector.
Electrochemical sensor/detector system and method
Glass, Robert S.; Perone, Sam P.; Ciarlo, Dino R.; Kimmons, James F.
1994-01-01
An electrochemical detection system is described comprising in combination: (a) a multielement, microelectrode array detector containing means for acquiring a plurality of signals; (b) electronic means for receiving said signals and converting said signals into a readout or display providing information with respect to the nature and concentration of elements present in a solution being tested. Also described is the means of making the above described microelectrode detector.
Lemaire, Edward; Greene, G
2003-01-01
We produced continuing education material in physical rehabilitation using a variety of electronic media. We compared four methods of delivering the learning modules: in person with a computer projector, desktop videoconferencing, Web pages and CD-ROM. Health-care workers at eight community hospitals and two nursing homes were asked to participate in the project. A total of 394 questionnaires were received for all modalities: 73 for in-person sessions, 50 for desktop conferencing, 227 for Web pages and 44 for CD-ROM. This represents a 100% response rate from the in-person, desktop conferencing and CD-ROM groups; the response rate for the Web group is unknown, since the questionnaires were completed online. Almost all participants found the modules to be helpful in their work. The CD-ROM group gave significantly higher ratings than the Web page group, although all four learning modalities received high ratings. A combination of all four modalities would be required to provide the best possible learning opportunity.
NASA Astrophysics Data System (ADS)
Seliverstov, S. V.; Anfertyev, V. A.; Tretyakov, I. V.; Ozheredov, I. A.; Solyankin, P. M.; Revin, L. S.; Vaks, V. L.; Rusova, A. A.; Goltsman, G. N.; Shkurinov, A. P.
2017-12-01
We study characteristics of the laboratory prototype of a terahertz heterodyne receiver with an electron-heating mixer and a heterodyne based on the quantum-cascade laser. The results obtained demonstrate the possibility to use this receiver as a basis for creation of a high-sensitivity terahertz spectrometer, which can be used in many basic and practical applications. A significant advantage of this receiver will be the possibility of placing the mixer and heterodyne in the same cryostat, which will reduce the device dimensions considerably. The obtained experimental results are analyzed, and methods of optimizing the parameters of the receiver are proposed.
Protti, Denis; Johansen, Ib
2010-03-01
Denmark is one of the world's leading countries in the use of health care technology. Virtually all primary care physicians have electronic medical records with full clinical functionality. Their systems are also connected to a national network, which allows them to electronically send and receive clinical data to and from consultant specialists, hospitals, pharmacies, and other health care providers. Under the auspices of a nonprofit organization called MedCom, over 5 million clinical messages are transferred monthly. One of the most important innovations has been the "one-letter solution," which allows one electronic form to be used for all types of letters to and from primary care physicians; it is used in over 5,000 health institutions with 50 different technology vendor systems.
Low Noise in a Diffusion-Cooled Hot-Electron Mixer at 2.5 THz
NASA Technical Reports Server (NTRS)
Karasik, B. S.; Gaidis, M. C.; McGrath, W. R.; Bumble, B.; LeDuc, H. G.
1997-01-01
The noise performance of a Nb hot-electron bolometer mixer at 2.5 THz has been investigated. The devices are fabricated from a 12-nm-thick Nb film, and have a 0.30 micrometer x 0.15 micrometer in-plane size, thus exploiting diffusion as the electron cooling mechanism. The rf coupling was provided by a twin-slot planar antenna on an elliptical Si lens. The experimentally measured double sideband noise temperature of the receiver was as low as 2750 +/- 250 K with an estimated mixer noise temperature of approximately equal 900 K. The mixer bandwidth derived from both noise bandwidth and IF impedance measurements was approximately equal 1.4 GHz. These results demonstrate the low-noise operation of the diffusion-cooled bolometer mixer above 2 THz.
Pies, Ross E.
2016-03-29
A method and device for the detection of impact events on a security barrier. A hollow rebar is farmed within a security barrier, whereby the hollow rebar is completely surrounded by the security barrier. An optical fiber passes through the interior of the hollow rebar. An optical transmitter and an optical receiver are both optically connected to the optical fiber and connected to optical electronics. The optical electronics are configured to provide notification upon the detection of an impact event at the security barrier based on the detection of disturbances within the optical fiber.
Pattern transfer printing by kinetic control of adhesion to an elastomeric stamp
Nuzzo, Ralph G [Champaign, IL; Rogers, John A [Champaign, IL; Menard, Etienne [Urbana, IL; Lee, Keon Jae [Tokyo, JP; Khang, Dahl-Young [Urbana, IL; Sun, Yugang [Champaign, IL; Meitl, Matthew [Champaign, IL; Zhu, Zhengtao [Urbana, IL
2011-05-17
The present invention provides methods, systems and system components for transferring, assembling and integrating features and arrays of features having selected nanosized and/or microsized physical dimensions, shapes and spatial orientations. Methods of the present invention utilize principles of `soft adhesion` to guide the transfer, assembly and/or integration of features, such as printable semiconductor elements or other components of electronic devices. Methods of the present invention are useful for transferring features from a donor substrate to the transfer surface of an elastomeric transfer device and, optionally, from the transfer surface of an elastomeric transfer device to the receiving surface of a receiving substrate. The present methods and systems provide highly efficient, registered transfer of features and arrays of features, such as printable semiconductor element, in a concerted manner that maintains the relative spatial orientations of transferred features.
NASA Astrophysics Data System (ADS)
Spencer, E. A.; Clark, D. C.; Vadepu, S. K.; Patra, S.
2017-12-01
A Time Domain Impedance Probe (TDIP) measures electron density and electron neutral collision frequencies in the ionosphere. This instrument has been tested on a sounding rocket flight and is now being further developed to fly on a NASA Undergraduate Student Instrument Program (USIP) cubesat to be launched out of the ISS in 2019. Here we report on the development of a new combined TDIP and plasma wave instrument that can be used on cubesat platforms to measure local electron parameters, and also to receive or transmit electron scale waves. This combined instrument can be used to study short time and space scale phenomena in the upper ionosphere using only RF signals. The front end analog circuitry is dual-purposed to perform active or passive probing of the ambient plasma. Two dipole antennas are used, one is optimzed for impedance measurements, while the other is optimized for transmitter-receiver performance. We show our circuit realization, and initial results from laboratory measurements using the TDIP prototype modified for receiver function. We also show Finite Difference Time Domain (FDTD) simulations of an electrically long antenna immersed in a magnetized plasma used to optimize the transmitter receiver performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raymund, T.D.
Recently, several tomographic techniques for ionospheric electron density imaging have been proposed. These techniques reconstruct a vertical slice image of electron density using total electron content data. The data are measured between a low orbit beacon satellite and fixed receivers located along the projected orbital path of the satellite. By using such tomographic techniques, it may be possible to inexpensively (relative to incoherent scatter techniques) image the ionospheric electron density in a vertical plane several times per day. The satellite and receiver geometry used to measure the total electron content data causes the data to be incomplete; that is, themore » measured data do not contain enough information to completely specify the ionospheric electron density distribution in the region between the satellite and the receivers. A new algorithm is proposed which allows the incorporation of other complementary measurements, such as those from ionosondes, and also includes ways to include a priori information about the unknown electron density distribution in the reconstruction process. The algorithm makes use of two-dimensional basis functions. Illustrative application of this algorithm is made to simulated cases with good results. The technique is also applied to real total electron content (TEC) records collected in Scandinavia in conjunction with the EISCAT incoherent scatter radar. The tomographic reconstructions are compared with the incoherent scatter electron density images of the same region of the ionosphere.« less
Gold, Rachel; DeVoe, Jennifer; Shah, Amit; Chauvie, Susan
2009-01-01
Background and Objectives Having health insurance is usually associated with better access to care and better health outcomes. For patients receiving care at Federally Qualified Health Centers (FQHCs), where care is provided regardless of insurance status, the role health insurance status plays in affecting receipt of services is less well understood. Research Design We used practice management data from a coalition of FQHCs in Oregon, and linked to Oregon’s electronic insurance data, to examine whether receipt of diabetes preventive care services was associated with continuity of insurance coverage among adult FQHC patients receiving diabetes care in 2005. Results About one-third (32%) of patients with diabetes received a flu vaccination in 2005, 36% an LDL screening, 54% at least one HbA1c screening, and 21% a nephropathy screening. Compared to the continuously insured, the continuously uninsured were less likely to receive an LDL screening, a flu vaccination, and/or a nephropathy screening; those with partial coverage were less likely than the continuously insured to receive a flu shot, at least one HbA1c screening, or an LDL screening. Conclusions Our results suggest that FQHCs do an excellent job in delivering most services to their uninsured and partially insured patients, but also underscore that for diabetic patients from underserved communities, having both an FQHC medical home and continuous health insurance plays a critical role in receiving optimal chronic disease management. Our study is one of the first to demonstrate how electronic administrative data from a network of FQHCs can be successfully used to gauge the state of healthcare delivery. PMID:19330890
Coupled Oscillator Based Agile Beam Transmitters and Receivers: A Review of Work at JPL
NASA Technical Reports Server (NTRS)
Pogorzelski, Ronald J.
2006-01-01
This is a review of the work done at Caltech's Jet Propulsion Laboratory during the past decade on development of the coupled oscillator technology in phased array applications to spacecraft telecommunications. First, some historical background is provided to set the work in context. However, this is by no means intended to be a comprehensive review of all work in this area. Rather, the focus is on the JPL contribution with some mention of other work which provided either insight or motivation. In the mid 1990's, R. A. York, and collaborators proposed that an array of mutually injection locked electronic oscillators could provide appropriately phased signals to the radiating elements of an array antenna such that the radiated beam could be steered merely by tuning the end or perimeter oscillators of the array. York, et al. also proposed a receiving system based on such oscillator arrays in which the oscillators provide properly phased local oscillator signals to be mixed with the signals received by the array elements to remove the phase due to angle of arrival of the incident wave. These concepts were viewed as a promising simplification of the beam steering control system that could result in significant cost, mass, and prime power reduction and were therefore attractive for possible space application.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-05
... Certain Electronic Devices Having a Digital Television Receiver and Components Thereof, DN 2801; the... importation of certain electronic devices having a digital television receiver and components thereof. The... health and welfare in the United States, competitive conditions in the United States economy, the...
Predicting mesoscale microstructural evolution in electron beam welding
Rodgers, Theron M.; Madison, Jonathan D.; Tikare, Veena; ...
2016-03-16
Using the kinetic Monte Carlo simulator, Stochastic Parallel PARticle Kinetic Simulator, from Sandia National Laboratories, a user routine has been developed to simulate mesoscale predictions of a grain structure near a moving heat source. Here, we demonstrate the use of this user routine to produce voxelized, synthetic, three-dimensional microstructures for electron-beam welding by comparing them with experimentally produced microstructures. When simulation input parameters are matched to experimental process parameters, qualitative and quantitative agreement for both grain size and grain morphology are achieved. The method is capable of simulating both single- and multipass welds. As a result, the simulations provide anmore » opportunity for not only accelerated design but also the integration of simulation and experiments in design such that simulations can receive parameter bounds from experiments and, in turn, provide predictions of a resultant microstructure.« less
Hybrid electronic/optical synchronized chaos communication system.
Toomey, J P; Kane, D M; Davidović, A; Huntington, E H
2009-04-27
A hybrid electronic/optical system for synchronizing a chaotic receiver to a chaotic transmitter has been demonstrated. The chaotic signal is generated electronically and injected, in addition to a constant bias current, to a semiconductor laser to produce an optical carrier for transmission. The optical chaotic carrier is photodetected to regenerate an electronic signal for synchronization in a matched electronic receiver The system has been successfully used for the transmission and recovery of a chaos masked message that is added to the chaotic optical carrier. Past demonstrations of synchronized chaos based, secure communication systems have used either an electronic chaotic carrier or an optical chaotic carrier (such as the chaotic output of various nonlinear laser systems). This is the first electronic/optical hybrid system to be demonstrated. We call this generation of a chaotic optical carrier by electronic injection.
Determinations of ionosphere and plasmasphere electron content for an African chain of GPS stations
NASA Astrophysics Data System (ADS)
Mazzella, Andrew J., Jr.; Bosco Habarulema, John; Yizengaw, Endawoke
2017-05-01
The confluence of recent instrumentation deployments in Africa with developments for the determination of plasmasphere electron content using Global Positioning System (GPS) receivers has provided new opportunities for investigations in that region. This investigation, using a selected chain of GPS stations, extends the method (SCORPION) previously applied to a chain of GPS stations in North America in order to separate the ionosphere and plasmasphere contributions to the total electron content (TEC) during a day (24 July) in 2011. The results span latitudes from the southern tip of Africa, across the Equator, to the southern Arabian Peninsula, providing a continuous latitudinal profile for both the ionosphere and plasmasphere during this day.The peak diurnal vertical ionosphere electron content (IEC) increases from about 14 TEC units (1 TEC unit = 1016 electrons m-2) at the southernmost station to about 32 TEC units near the geographic equator, then decreases to about 28 TEC units at the Arabian Peninsula. The peak diurnal slant plasmasphere electron content (PEC) varies between about 4 and 7 TEC units among the stations, with a local latitudinal profile that is significantly influenced by the viewing geometry at the station location, relative to the magnetic field configuration. In contrast, the peak vertical PEC varies between about 1 and 6 TEC units among the stations, with a more uniform latitudinal variation.Comparisons to other GPS data analyses are also presented for TEC, indicating the influence of the PEC on the determination of latitudinal TEC variations and also on the absolute TEC levels, by inducing an overestimate of the receiver bias. The derived TEC latitudinal profiles, in comparison to global map profiles, tend to differ from the map results only about as much as the map results differ among themselves. A combination of ionosonde IEC and alternative GPS TEC measurements, which in principle permits a PEC determination through their difference, was compared to the composite and separate ionosphere and plasmasphere contributions derived solely by the SCORPION method for one station. Although there is considerably more scatter in the PEC values derived from the difference of the GPS TEC and ionosonde IEC measurements compared to the PEC values derived by the SCORPION method, the average overhead values for this day are comparable for the two methods, near 2 TEC units, at the South African site examined.This initial investigation provides a basis for day-to-day TEC monitoring for Africa, with separate ionosphere and plasmasphere electron content determinations.
The CuSPED Mission: CubeSat for GNSS Sounding of the Ionosphere-Plasmasphere Electron Density
NASA Technical Reports Server (NTRS)
Gross, Jason N.; Keesee, Amy M.; Christian, John A.; Gu, Yu; Scime, Earl; Komjathy, Attila; Lightsey, E. Glenn; Pollock, Craig J.
2016-01-01
The CubeSat for GNSS Sounding of Ionosphere-Plasmasphere Electron Density (CuSPED) is a 3U CubeSat mission concept that has been developed in response to the NASA Heliophysics program's decadal science goal of the determining of the dynamics and coupling of the Earth's magnetosphere, ionosphere, and atmosphere and their response to solar and terrestrial inputs. The mission was formulated through a collaboration between West Virginia University, Georgia Tech, NASA GSFC and NASA JPL, and features a 3U CubeSat that hosts both a miniaturized space capable Global Navigation Satellite System (GNSS) receiver for topside atmospheric sounding, along with a Thermal Electron Capped Hemispherical Spectrometer (TECHS) for the purpose of in situ electron precipitation measurements. These two complimentary measurement techniques will provide data for the purpose of constraining ionosphere-magnetosphere coupling models and will also enable studies of the local plasma environment and spacecraft charging; a phenomenon which is known to lead to significant errors in the measurement of low-energy, charged species from instruments aboard spacecraft traversing the ionosphere. This paper will provide an overview of the concept including its science motivation and implementation.
R.F Microphotonics for NASA Space Communications Applications
NASA Technical Reports Server (NTRS)
Pouch, John; Nguyen, Hung; Lee, Richard; Miranda, Felix; Hossein-Zadeh, Mani; Cohen, David; Levi, A. F. J.
2007-01-01
An RF microphotonic receiver has-been developed at Ka-band. The receiver consists of a lithium niobate micro-disk that enables RF-optical coupling to occur. The modulated optical signal (- 200 THz) is detected by the high-speed photonic signal processing electronics. When compared with an electronic approach, the microphotonic receiver technology offers 10 times smaller volume, smaller weight, and smaller power consumption; greater sensitivity; and optical isolation for use in extreme environments. The status of the technology development will be summarized, and the potential application of the receiver to NASA space communications systems will be described.
Design and realization of an active SAR calibrator for TerraSAR-X
NASA Astrophysics Data System (ADS)
Dummer, Georg; Lenz, Rainer; Lutz, Benjamin; Kühl, Markus; Müller-Glaser, Klaus D.; Wiesbeck, Werner
2005-10-01
TerraSAR-X is a new earth observing satellite which will be launched in spring 2006. It carries a high resolution X-band SAR sensor. For high image data quality, accurate ground calibration targets are necessary. This paper describes a novel system concept for an active and highly integrated, digitally controlled SAR system calibrator. A total of 16 active transponder and receiver systems and 17 receiver only systems will be fabricated for a calibration campaign. The calibration units serve for absolute radiometric calibration of the SAR image data. Additionally, they are equipped with an extra receiver path for two dimensional satellite antenna pattern recognition. The calibrator is controlled by a dedicated digital Electronic Control Unit (ECU). The different voltages needed by the calibrator and the ECU are provided by the third main unit called Power Management Unit (PMU).
Ryan, Andrew M; Bishop, Tara F; Shih, Sarah; Casalino, Lawrence P
2013-01-01
The 2009 American Recovery and Reinvestment Act spurred adoption of electronic health records (EHRs) in the United States, through such measures as financial incentives to providers through Medicare and Medicaid and regional extension centers, which provide ongoing technical assistance to practices. Yet the relationship between EHR adoption and quality of care remains poorly understood. We evaluated the early effects on quality of the Primary Care Information Project, which provides subsidized EHRs and technical assistance to primary care practices in underserved neighborhoods in New York City, using the regional extension center model. We found that just general participation in, or exposure to, the project was not enough to improve quality of care. It took sustained exposure on the part of these practices and technical assistance to them before they demonstrated improvement on measures of care most likely to be affected by the use of electronic health records, such as cancer screenings and care for patients with diabetes. Participating in the Primary Care Information Project for nine or more months was associated with significantly improved quality, but only for this limited group of quality measures and only for physicians receiving extensive technical assistance.
NASA Astrophysics Data System (ADS)
Liu, Xia; Peyton, Liam; Kuziemsky, Craig
Health care is increasingly provided to citizens by a network of collaboration that includes multiple providers and locations. Typically, that collaboration is on an ad-hoc basis via phone calls, faxes, and paper based documentation. Internet and wireless technologies provide an opportunity to improve this situation via electronic data sharing. These new technologies make possible new ways of working and collaboration but it can be difficult for health care organizations to understand how to use the new technologies while still ensuring that their policies and objectives are being met. It is also important to have a systematic approach to validate that e-health processes deliver the performance improvements that are expected. Using a case study of a palliative care patient receiving home care from a team of collaborating health organizations, we introduce a framework based on requirements engineering. Key concerns and objectives are identified and modeled (privacy, security, quality of care, and timeliness of service). And, then, proposed business processes which use new technologies are modeled in terms of these concerns and objectives to assess their impact and ensure that electronic data sharing is well regulated.
Moving receive beam method and apparatus for synthetic aperture radar
Kare, Jordin T.
2001-01-01
A method and apparatus for improving the performance of Synthetic Aperture Radar (SAR) systems by reducing the effect of "edge losses" associated with nonuniform receiver antenna gain. By moving the receiver antenna pattern in synchrony with the apparent motion of the transmitted pulse along the ground, the maximum available receiver antenna gain can be used at all times. Also, the receiver antenna gain for range-ambiguous return signals may be reduced, in some cases, by a large factor. The beam motion can be implemented by real-time adjustment of phase shifters in an electronically-steered phased-array antenna or by electronic switching of feed horns in a reflector antenna system.
Dennis, Amanda; Blanchard, Kelly
2013-01-01
Objective To evaluate the implementation of state Medicaid abortion policies and the impact of these policies on abortion clients and abortion providers. Data Source From 2007 to 2010, in-depth interviews were conducted with representatives of 70 abortion-providing facilities in 15 states. Study Design In-depth interviews focused on abortion providers' perceptions regarding Medicaid and their experiences working with Medicaid and securing reimbursement in cases that should receive federal funding: rape, incest, and life endangerment. Data Extraction Data were transcribed verbatim before being coded. Principal Findings In two study states, abortion providers reported that 97 percent of submitted claims for qualifying cases were funded. Success receiving reimbursement was attributed to streamlined electronic billing procedures, timely claims processing, and responsive Medicaid staff. Abortion providers in the other 13 states reported reimbursement for 36 percent of qualifying cases. Providers reported difficulties obtaining reimbursement due to unclear rejections of qualifying claims, complex billing procedures, lack of knowledgeable Medicaid staff with whom billing problems could be discussed, and low and slow reimbursement rates. Conclusions Poor state-level implementation of Medicaid coverage of abortion policies creates barriers for women seeking abortion. Efforts to ensure policies are implemented appropriately would improve women's health. PMID:22742741
Dennis, Amanda; Blanchard, Kelly
2013-02-01
To evaluate the implementation of state Medicaid abortion policies and the impact of these policies on abortion clients and abortion providers. From 2007 to 2010, in-depth interviews were conducted with representatives of 70 abortion-providing facilities in 15 states. In-depth interviews focused on abortion providers' perceptions regarding Medicaid and their experiences working with Medicaid and securing reimbursement in cases that should receive federal funding: rape, incest, and life endangerment. Data were transcribed verbatim before being coded. In two study states, abortion providers reported that 97 percent of submitted claims for qualifying cases were funded. Success receiving reimbursement was attributed to streamlined electronic billing procedures, timely claims processing, and responsive Medicaid staff. Abortion providers in the other 13 states reported reimbursement for 36 percent of qualifying cases. Providers reported difficulties obtaining reimbursement due to unclear rejections of qualifying claims, complex billing procedures, lack of knowledgeable Medicaid staff with whom billing problems could be discussed, and low and slow reimbursement rates. Poor state-level implementation of Medicaid coverage of abortion policies creates barriers for women seeking abortion. Efforts to ensure policies are implemented appropriately would improve women's health. © Health Research and Educational Trust.
Scex 3 and Electron Echo 7, a Comparison of Data from Two Rocket Experiments.
NASA Astrophysics Data System (ADS)
Bale, Stuart Douglas
Results from two separate active sounding rocket experiments are presented and discussed. The SCEX III sounding rocket (NASA 39.002 UE) and Electron Echo 7 (NASA 36.015) were both launched from the Poker Flat Research Range (65.1^circ N, 147.5^circ W) near Fairbanks, Alaska, on 1 February, 1990 and 9 February, 1988, respectively. Each payload was equipped with an electron accelerator to study both natural and beam-related plasma phenomena. Data from the SCEX III retarding potential analyzer (RPA) and 3805 A and 3914 A photometers show evidence of a plasma discharge process occurring concomitant with operation of the electron gun. This appears as an enhanced electron current, nonlinear with gun injection current, in the RPA. The photometers register a sharp increase in luminosity during full current electron injection. This luminosity is an indicator of the ionizing electron-neutral collisions which liberate electrons and lead to the cascade-type discharge process. These observations are used to attempt to infer the mechanism of electron acceleration which leads to the discharge process. Before the electron gun was activated, the SCEX III payload flew through a region of auroral activity as evidenced by ground-based all-sky TV and energetic particle flux in the forward payload RPA. During this time, low frequency (10 Hz) electrostatic waves were observed in the DC receivers and Langmuir probe instrument. This data is analyzed, with a cross-spectral technique, and an approximate wave number is inferred. Comparison with theory suggests that the observed wave is the electrostatic ion cyclotron mode (EIC) operating on a heavy ion species (NO or O _2). The Echo 7 nose payload, carrying a plasma wave receiver, was ejected upfield of the main electron gun -equipped payload. Data from the swept frequency analyzer experiment provide wave amplitudes, at frequencies up to 15 MHz, as a function of separation of the main and nose payloads. These observations, and the wave modes inferred, shed light on the wave generation region upfield from a beam-emitting ionospheric payload.
Ultraino: An Open Phased-Array System for Narrowband Airborne Ultrasound Transmission.
Marzo, Asier; Corkett, Tom; Drinkwater, Bruce W
2018-01-01
Modern ultrasonic phased-array controllers are electronic systems capable of delaying the transmitted or received signals of multiple transducers. Configurable transmit-receive array systems, capable of electronic steering and shaping of the beam in near real-time, are available commercially, for example, for medical imaging. However, emerging applications, such as ultrasonic haptics, parametric audio, or ultrasonic levitation, require only a small subset of the capabilities provided by the existing controllers. To meet this need, we present Ultraino, a modular, inexpensive, and open platform that provides hardware, software, and example applications specifically aimed at controlling the transmission of narrowband airborne ultrasound. Our system is composed of software, driver boards, and arrays that enable users to quickly and efficiently perform research in various emerging applications. The software can be used to define array geometries, simulate the acoustic field in real time, and control the connected driver boards. The driver board design is based on an Arduino Mega and can control 64 channels with a square wave of up to 17 Vpp and /5 phase resolution. Multiple boards can be chained together to increase the number of channels. The 40-kHz arrays with flat and spherical geometries are demonstrated for parametric audio generation, acoustic levitation, and haptic feedback.
Ground station software for receiving and handling Irecin telemetry data
NASA Astrophysics Data System (ADS)
Ferrante, M.; Petrozzi, M.; Di Ciolo, L.; Ortenzi, A.; Troso, G
2004-11-01
The on board resources, needed to perform the mission tasks, are very limited in nano-satellites. This paper proposes a software system to receive, manage and process in Real Time the Telemetry data coming from IRECIN nanosatellite and transmit operator manual commands and operative procedures. During the receiving phase, it shows the IRECIN subsystem physical values, visualizes the IRECIN attitude, and performs other suitable functions. The IRECIN Ground Station program is in charge to exchange information between IRECIN and the Ground segment. It carries out, in real time during IRECIN transmission phase, IRECIN attitude drawing, sun direction drawing, power supply received from Sun, visualization of the telemetry data, visualization of Earth magnetic field and more other functions. The received data are memorized and interpreted by a module, parser, and distribute to the suitable modules. Moreover it allows sending manual and automatic commands. Manual commands are delivered by an operator, on the other hand, automatic commands are provided by pre-configured operative procedures. Operative procedures development is realized in a previous phase called configuration phase. This program is also in charge to carry out a test session by mean the scheduler and commanding modules allowing execution of specific tasks without operator control. A log module to memorize received and transmitted data is realized. A phase to analyze, filter and visualize in off line the collected data, called post analysis, is based on the data extraction form the log module. At the same time, the Ground Station Software can work in network allowing managing, receiving and sending data/commands from different sites. The proposed system constitutes the software of IRECIN Ground Station. IRECIN is a modular nanosatellite weighting less than 2 kg, constituted by sixteen external sides with surface-mounted solar cells and three internal Al plates, kept together by four steel bars. Lithium-ions batteries are used. Attitude is determined by two three-axis magnetometers and the solar panels data. Control is provided by an active magnetic control system. The spacecraft will be spin- stabilized with the spin-axis normal to the orbit. All IRECIN electronic components are SMD technology in order to reduce weight and size. The realized Electronic board are completely developed, realized and tested at the Vitrociset S.P.A. under control of Research and Develop Group
Receivers and Transmitters. Electronics Module 6. Instructor's Guide.
ERIC Educational Resources Information Center
Everett, Jim
This module is the sixth of 10 modules in the competency-based electronics series. Introductory materials include a listing of competencies addressed in the module and a cross-reference table of instructional materials. Two instructional units cover: (1) AM/FM transmitter and receiver basics; and (2) satellite systems, antennas, and analyzers.…
Spire's 3U CubeSat GNSS-RO Constellation for Meteorological and Space Weather Applications
NASA Astrophysics Data System (ADS)
Nguyen, V.; Duly, T.; Ector, D.; Irisov, V.; Nogues-Correig, O.; Tan, L.; Yuasa, T.
2017-12-01
Spire Global, Inc., is a leading player in the nanosatellite sector and the first commercial company to provide GNSS radio occultation measurements to support meteorological and space weather forecasting. Each Spire satellite is equipped with a state-of-the-art, in-house designed software receiver, which is capable of open-loop tracking of occulted GNSS signals. By utilizing this receiver on a low-earth orbiting, 3U satellite constellation platform, Spire is able to provide high-quality profile measurements of the lower atmosphere as well as ionospheric total electron content and scintillation data at unprecedented low cost, coverage, and latency. In this talk, we provide an overview of the current capabilities of Spire's satellite constellation and radio occultation processing system. Recent results describing the state of the lower atmosphere and ionosphere will be presented and briefly discussed. Finally, we focus on Spire's future capabilities, and the potential impacts on both the meteorological and space weather scientific communities.
The Use of Electronic Mail in Biomedical Communication
Costello, Richard; Shaw, Anthony; Cheetham, Roz; Moots, Robert J.
2000-01-01
Objectives: To determine whether there are statistically significant differences in the content of electronic mail (e-mail) and conventional mail sent to authors of papers published in medical journals. Design: Prospective study by postal questionnaire. Over two one-month periods, corresponding authors of papers published in medical journals were asked to record details of the correspondence prompted by their publications. Measurements: Conventional and e-mail correspondence received. Reprint requests. Content of correspondence. Quality of correspondence. Results: Eighty-two of 96 authors replied. Fifty received e-mail (mean, 5.7 ± 8.8 e-mails per author) and 72 received conventional mail (15.5 ± 32.8 letters per author) (p ≪ 0.05). Seventy percent of e-mails and only 53% of correspondence sent by conventional mail (p ≪ 0.05) referred to the content of the paper. Conclusions: Publication in general medical journals stimulates more conventional than electronic mail. However, the content of e-mail may be of greater scientific relevance. Electronic mail can be encouraged without fear of diminishing the quality of the communications received. PMID:10641967
Analysis of strong scintillation events by using GPS data at low latitudes
NASA Astrophysics Data System (ADS)
Forte, Biagio; Jakowski, Norbert; Wilken, Volker
2010-05-01
Drifting structures charaterised by inhomogeneities in the spatial electron density distribution at ionospheric heights originate scintillation of radio waves propagating through. The fractional electron density fluctuations and the corresponding scintillation levels may reach extreme values at low latitudes during high solar activity. Strong scintillation events have disruptive effects on a number of technological applications. In particular, operations and services based on GPS signals and receivers may experience severe disruption due to a significant degradation of the signal-to-noise ratio, eventually leading to signal loss of lock. Experimental scintillation data collected in the Asian sector at low latitudes by means of a GPS dual frequency receiver under moderate solar activity (2006) have been analysed. The GPS receiver is particularly modified in firmware in order to record power estimates on the C/A code as well as on the carriers L1 and L2. Strong scintillation activity is recorded in the post-sunset period (saturating S4 and SI as high as 20 dB). An overview of these events is presented, by taking into account scintillation impact on the signal intensity, phase, and dynamics. In particular, the interpretation of these events based on a refined scattering theory is provided with possible consequences for standard scintillation models.
Frontend Receiver Electronics for High Frequency Monolithic CMUT-on-CMOS Imaging Arrays
Gurun, Gokce; Hasler, Paul; Degertekin, F. Levent
2012-01-01
This paper describes the design of CMOS receiver electronics for monolithic integration with capacitive micromachined ultrasonic transducer (CMUT) arrays for high-frequency intravascular ultrasound imaging. A custom 8-inch wafer is fabricated in a 0.35 μm two-poly, four-metal CMOS process and then CMUT arrays are built on top of the application specific integrated circuits (ASICs) on the wafer. We discuss advantages of the single-chip CMUT-on-CMOS approach in terms of receive sensitivity and SNR. Low-noise and high-gain design of a transimpedance amplifier (TIA) optimized for a forward-looking volumetric-imaging CMUT array element is discussed as a challenging design example. Amplifier gain, bandwidth, dynamic range and power consumption trade-offs are discussed in detail. With minimized parasitics provided by the CMUT-on-CMOS approach, the optimized TIA design achieves a 90 fA/√Hz input referred current noise, which is less than the thermal-mechanical noise of the CMUT element. We show successful system operation with a pulse-echo measurement. Transducer noise-dominated detection in immersion is also demonstrated through output noise spectrum measurement of the integrated system at different CMUT bias voltages. A noise figure of 1.8 dB is obtained in the designed CMUT bandwidth of 10 MHz to 20 MHz. PMID:21859585
Front-end receiver electronics for high-frequency monolithic CMUT-on-CMOS imaging arrays.
Gurun, Gokce; Hasler, Paul; Degertekin, F
2011-08-01
This paper describes the design of CMOS receiver electronics for monolithic integration with capacitive micromachined ultrasonic transducer (CMUT) arrays for highfrequency intravascular ultrasound imaging. A custom 8-inch (20-cm) wafer is fabricated in a 0.35-μm two-poly, four-metal CMOS process and then CMUT arrays are built on top of the application specific integrated circuits (ASICs) on the wafer. We discuss advantages of the single-chip CMUT-on-CMOS approach in terms of receive sensitivity and SNR. Low-noise and high-gain design of a transimpedance amplifier (TIA) optimized for a forward-looking volumetric-imaging CMUT array element is discussed as a challenging design example. Amplifier gain, bandwidth, dynamic range, and power consumption trade-offs are discussed in detail. With minimized parasitics provided by the CMUT-on-CMOS approach, the optimized TIA design achieves a 90 fA/√Hz input-referred current noise, which is less than the thermal-mechanical noise of the CMUT element. We show successful system operation with a pulseecho measurement. Transducer-noise-dominated detection in immersion is also demonstrated through output noise spectrum measurement of the integrated system at different CMUT bias voltages. A noise figure of 1.8 dB is obtained in the designed CMUT bandwidth of 10 to 20 MHz.
Comparison of IRI-Plas and IONOLAB Slant Total Electron Content for Disturbed Days of Ionosphere
NASA Astrophysics Data System (ADS)
Shukurov, Seymur; Gulyaeva, Tamara; Arikan, Feza; Necat Deviren, M.; Tuna, Hakan; Arikan, Orhan
Variabilities due to geomagnetic, and seismic activities in ionosphere can be observed by using Total Electron Content (TEC). TEC estimated on a path between a dual-frequency Global Positioning System (GPS) receiver and a GPS satellite at a given date and time is called Slant TEC (STEC). STEC contains the variability of ionosphere on a given path, therefore it is a useful variable to identify the anisotropicity. IONOLAB group has developed a novel method for STEC estimation (IONOLAB-STEC) from GPS phase delay recordings resolving the phase ambiguity and calculating IONOLAB-BIAS as receiver interfrequency bias. International Reference Ionosphere Extended to Plasmasphere (IRI-Plas) is the standard climatic model of ionosphere. IONOLAB group automatized the computation of STEC between a GPS satellite and receiver for a given date. In this study, IRI-Plas-STEC and IONOLAB-STEC are compared for geomagnetically active storm days and for the days prior to earthquakes over Turkey using Symmetric Kullback-Liebler Distance (SKLD). It is observed that IRI-Plas-STEC and IONOLAB-STEC are very similar for magnetically quiet days, and IRI-Plas-STEC provides a background ionosphere. This study is supported by the joint grant of TUBITAK 112E568 and RFBR 13-02-91370-CT_a.
Yang, Shao-Hua; Li, Wenjun; Sumien, Nathalie; Forster, Michael; Simpkins, James W; Liu, Ran
2017-10-01
Brain has exceptional high requirement for energy metabolism with glucose as the exclusive energy source. Decrease of brain energy metabolism and glucose uptake has been found in patients of Alzheimer's, Parkinson's and other neurodegenerative diseases, providing a clear link between neurodegenerative disorders and energy metabolism. On the other hand, cancers, including glioblastoma, have increased glucose uptake and rely on aerobic glycolysis for energy metabolism. The switch of high efficient oxidative phosphorylation to low efficient aerobic glycolysis pathway (Warburg effect) provides macromolecule for biosynthesis and proliferation. Current research indicates that methylene blue, a century old drug, can receive electron from NADH in the presence of complex I and donates it to cytochrome c, providing an alternative electron transfer pathway. Methylene blue increases oxygen consumption, decrease glycolysis, and increases glucose uptake in vitro. Methylene blue enhances glucose uptake and regional cerebral blood flow in rats upon acute treatment. In addition, methylene blue provides protective effect in neuron and astrocyte against various insults in vitro and in rodent models of Alzheimer's, Parkinson's, and Huntington's disease. In glioblastoma cells, methylene blue reverses Warburg effect by enhancing mitochondrial oxidative phosphorylation, arrests glioma cell cycle at s-phase, and inhibits glioma cell proliferation. Accordingly, methylene blue activates AMP-activated protein kinase, inhibits downstream acetyl-coA carboxylase and cyclin-dependent kinases. In summary, there is accumulating evidence providing a proof of concept that enhancement of mitochondrial oxidative phosphorylation via alternative mitochondrial electron transfer may offer protective action against neurodegenerative diseases and inhibit cancers proliferation. Copyright © 2015 Elsevier Ltd. All rights reserved.
Investigation of the High Latitude Magnetosphere and its Response to the Solar Wind
NASA Technical Reports Server (NTRS)
Taylor, William W. L.
1996-01-01
INSPIRE is a non-profit scientific, educational corporation whose objective is to bring the excitement of observing natural and manmade radio waves in the audio region to high school students. Stimulating students to learn and understand science and technology is the key to them fulfilling their potential in the best interests of our society. INSPIRE also is an innovative, unique opportunity for students to actively gather data that might be used in a basic research project. INSPIRE began with a test bed project, ACTIVE/HSGS, which involved 100 high schools, with a centerpiece of making observations of 10.5 kHz transmissions from the Soviet ACTIVE satellite. A large number of ground receiving sites was needed, both to enhance the probability of receiving the radio waves from ACTIVE, and to determine the propagation paths to the ground. The second major project was support to SEPAC (Space Experiments using Particle ACcelerators), a payload on the ATLAS I Spacelab mission, flown in March/April 1992. With its electron accelerator SEPAC performed many experiments in the ionosphere, including producing an artificial aurora and the electromagnetic waves produced by pulsing the electron beam. INSPIRE/SEPAC provided more than 1000 ground stations to receive the radio waves, and, at the same time, allowed high school students the opportunity to take data that would be used in a published basic research project. The third major project is to make observations of the effects of a pulsed electron beam and plasma generator on the MIR Space Station. On request, these instruments are operated over INSPIRE observers.
0.5-45GHz Simultaneous Transmit and Receive (STAR) Antenna System for Electronic Attack
2016-03-17
0.5-45GHz Simultaneous Transmit and Receive (STAR) Antenna System for Electronic Attack Mohamed Elmansouri, Prathap Valaleprasannakumar, Elie...Colorado, US, 80309 Abstract: A shared antenna aperture for simultaneous transmit and receive (STAR) operating from 0.5 to 45GHz with isolation...50dB over the entire band is discussed. The co-located antenna aperture system is designed across 4 overlapping bands: 0.5-2.5GHz, 2-7GHz, 6-19GHz
Microscale Digital Vacuum Electronic Gates
NASA Technical Reports Server (NTRS)
Manohara, Harish (Inventor); Mojarradi, Mohammed M. (Inventor)
2014-01-01
Systems and methods in accordance with embodiments of the invention implement microscale digital vacuum electronic gates. In one embodiment, a microscale digital vacuum electronic gate includes: a microscale field emitter that can emit electrons and that is a microscale cathode; and a microscale anode; where the microscale field emitter and the microscale anode are disposed within at least a partial vacuum; where the microscale field emitter and the microscale anode are separated by a gap; and where the potential difference between the microscale field emitter and the microscale anode is controllable such that the flow of electrons between the microscale field emitter and the microscale anode is thereby controllable; where when the microscale anode receives a flow of electrons, a first logic state is defined; and where when the microscale anode does not receive a flow of electrons, a second logic state is defined.
Magnuson, J A; Klockner, Rocke; Ladd-Wilson, Stephen; Zechnich, Andrew; Bangs, Christopher; Kohn, Melvin A
2004-01-01
Electronic emergency department reporting provides the potential for enhancing local and state surveillance capabilities for a wide variety of syndromes and reportable conditions. The task of protecting data confidentiality and integrity while developing electronic data interchange between a hospital emergency department and a state public health department proved more complex than expected. This case study reports on the significant challenges that had to be resolved to accomplish this goal; these included application restrictions and incompatibilities, technical malfunctions, changing standards, and insufficient dedicated resources. One of the key administrative challenges was that of coordinating project security with enterprise security. The original project has evolved into an ongoing pilot, with the health department currently receiving secure data from the emergency department at four-hour intervals. Currently, planning is underway to add more emergency departments to the project.
Addressing critical gaps in the treatment of eating disorders.
Kazdin, Alan E; Fitzsimmons-Craft, Ellen E; Wilfley, Denise E
2017-03-01
Remarkable progress has been made in developing psychosocial interventions for eating disorders and other mental disorders. Two priorities in providing treatment consist of addressing the research-practice gap and the treatment gap. The research-practice gap pertains to the dissemination of evidence-based treatments from controlled settings to routine clinical care. Closing the gap between what is known about effective treatment and what is actually provided to patients who receive care is crucial in improving mental health care, particularly for conditions such as eating disorders. The treatment gap pertains to extending treatments in ways that will reach the large number of people in need of clinical care who currently receive nothing. Currently, in the United States (and worldwide), the vast majority of individuals in need of mental health services for eating disorders and other mental health problems do not receive treatment. This article discusses the approaches required to better ensure: (1) that more people who are receiving treatment obtain high-quality, evidence-based care, using such strategies as train-the-trainer, web-centered training, best-buy interventions, electronic support tools, higher-level support and policy; and (2) that a higher proportion of those who are currently underserved receive treatment, using such strategies as task shifting and disruptive innovations, including treatment delivery via telemedicine, the Internet, and mobile apps. © 2017 Wiley Periodicals, Inc.
Huang, Xuechen; Denprasert, Petcharat May; Zhou, Li; Vest, Adriana Nicholson; Kohan, Sam; Loeb, Gerald E
2017-09-01
We have developed and applied new methods to estimate the functional life of miniature, implantable, wireless electronic devices that rely on non-hermetic, adhesive encapsulants such as epoxy. A comb pattern board with a high density of interdigitated electrodes (IDE) could be used to detect incipient failure from water vapor condensation. Inductive coupling of an RF magnetic field was used to provide DC bias and to detect deterioration of an encapsulated comb pattern. Diodes in the implant converted part of the received energy into DC bias on the comb pattern. The capacitance of the comb pattern forms a resonant circuit with the inductor by which the implant receives power. Any moisture affects both the resonant frequency and the Q-factor of the resonance of the circuitry, which was detected wirelessly by its effects on the coupling between two orthogonal RF coils placed around the device. Various defects were introduced into the comb pattern devices to demonstrate sensitivity to failures and to correlate these signals with visual inspection of failures. Optimized encapsulation procedures were validated in accelerated life tests of both comb patterns and a functional neuromuscular stimulator under development. Strong adhesive bonding between epoxy and electronic circuitry proved to be necessary and sufficient to predict 1 year packaging reliability of 99.97% for the neuromuscular stimulator.
Optical wireless communications to OC-768 and beyond
NASA Astrophysics Data System (ADS)
Medved, David B.; Davidovich, Leonid
2001-10-01
Laser and LED-based wireless communication systems are currently providing license-free interconnection for broadband voice, data and video transport. These systems allow for the immediate, reliable and low-cost extension of copper and fiber-based networks to any end user, providing efficient First Mile bypass access to high data rate backbone networks at speeds ranging from T-1 voice to full throughput ATM at 155 Mbps and up to Gigabit Ethernet. These wireless optical beams constitute a Virtual Fiber in the air, providing the capabilities of fiber in situations where wired connectivity is unavailable, impractical, expensive or slow-to-implement, while achieving a combination of low cost, speed and reliability that cannot be matched by microwave, mm wave, spread spectrum or other competing (actually complementary) wireless technologies. The carrier frequency of the optical beam is about 10,000 times higher than the highest frequencies used by the millimeter wave technology. By means of Wavelength Division Multiplexing more than 1000 independent data channels can be projected into the air on a single beam thus providing a potential bandwidth ten million times that of any RF solution. The twin barriers of physics and regulatory bureaucracy to this essentially infinite wireless bandwidth are thus eliminated by this Virtual Fiber. As user density and individual bandwidth needs escalate, the optical wireless will be the preferred medium of choice in both network and cellular interconnection. A mesh topology which integrates our optical wireless systems with the latest Optical Access switches and routing equipment will be described using case study examples from Japan to South America. As the Bandwidth Blowout continues to push the limits of electronics and especially in the case of DWDM (Dense Wavelength Division Multiples), the conventional optical wireless solutions are no longer feasible. Instead of using f.o. transceivers to convert photons to electrons and thence back to photons we have designed a series of airlinks whose transmitters and receivers operate without electronics. At the PATX (Photonic Airlink Transmitter), instead of demodulating the fiber optic input signals from a Network Interface Unit (NIU) we project the light from the polished terminated fiber end into the air using appropriate optics. Any signal being carried by the fiber from the NIU is now airborne without any intermediate processing electronics thus realizing the full potential of the optical carrier. At the receiver end (PARX - Photonic Airlink Receiver), the weak optical signals are collected by the appropriate optics (including combiners using large area MMF) and guided to the NIU (switch, PABX, etc.) by compatible fiber. It is necessary to maintain a large field-of-view at the receiver to ensure reliability, stability and ease of alignment. This is achieved by use of high N.A. fiber. In this paper we discuss the design trade off's, construction and field test results of several systems implementing the all- photonic wireless concept including: Transmission of WDM signals through the air at distances up to 1 km. Results with wireless transmission of Gigabit Ethernet using the Optiswitch modules as the NIU. Providing high speed wireless (Fast Ethernet and beyond) to the home at a cost of less than $250 per node. The paper will conclude with a discussion on the role of the all-photonic wireless technology in the emerging field of Passive Optical Networking.
Airborne Optical Communications Demonstrator Design And Preflight Test Results
NASA Technical Reports Server (NTRS)
Biswas, Abhijit; Page, N.; Neal, J.; Zhu, D.; Wright, M.; Ovtiz, G.; Farr, W. H.; Hernnzati, H.
2005-01-01
A second generation optical communications demonstrator (OCD-2) intended for airborne applications like air-to-ground and air-to-air optical links is under development at JPL. This development provides the capability for unidirectional high data rate (2.5-Gbps) transmission at 1550-nm, with the ability to receive an 810-nm beacon to aid acquisition pointing and tracking. The transmitted beam width is nominally 200-(micro)rad. A 3x3 degree coarse field-of-view (FOV) acquisition sensor with a much smaller 3-mrad FOV tracking sensor is incorporated. The OCD-2 optical head will be integrated to a high performance gimbal turret assembly capable of providing pointing stability of 5- microradians from an airborne platform. Other parts of OCD-2 include a cable harness, connecting the optical head in the gimbal turret assembly to a rugged electronics box. The electronics box will house: command and control processors, laser transmitter, data-generation-electronics, power conversion/distribution hardware and state-of-health monitors. The entire assembly will be integrated and laboratory tested prior to a planned flight demonstrations.
47 CFR 15.118 - Cable ready consumer electronics equipment.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Cable ready consumer electronics equipment. 15... Unintentional Radiators § 15.118 Cable ready consumer electronics equipment. (a) All consumer electronics TV... provisions of this section. Consumer electronics TV receiving equipment that includes features intended for...
40 CFR 233.39 - Electronic reporting.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Electronic reporting. 233.39 Section... PROGRAM REGULATIONS Program Operation § 233.39 Electronic reporting. States that choose to receive electronic documents must satisfy the requirements of 40 CFR Part 3—(Electronic reporting) in their state...
40 CFR 233.39 - Electronic reporting.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Electronic reporting. 233.39 Section... PROGRAM REGULATIONS Program Operation § 233.39 Electronic reporting. States that choose to receive electronic documents must satisfy the requirements of 40 CFR Part 3—(Electronic reporting) in their state...
40 CFR 233.39 - Electronic reporting.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Electronic reporting. 233.39 Section... PROGRAM REGULATIONS Program Operation § 233.39 Electronic reporting. States that choose to receive electronic documents must satisfy the requirements of 40 CFR Part 3—(Electronic reporting) in their state...
40 CFR 233.39 - Electronic reporting.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Electronic reporting. 233.39 Section... PROGRAM REGULATIONS Program Operation § 233.39 Electronic reporting. States that choose to receive electronic documents must satisfy the requirements of 40 CFR Part 3—(Electronic reporting) in their state...
40 CFR 233.39 - Electronic reporting.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Electronic reporting. 233.39 Section... PROGRAM REGULATIONS Program Operation § 233.39 Electronic reporting. States that choose to receive electronic documents must satisfy the requirements of 40 CFR Part 3—(Electronic reporting) in their state...
47 CFR 15.118 - Cable ready consumer electronics equipment.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Cable ready consumer electronics equipment. 15... Unintentional Radiators § 15.118 Cable ready consumer electronics equipment. (a) All consumer electronics TV... provisions of this section. Consumer electronics TV receiving equipment that includes features intended for...
47 CFR 15.118 - Cable ready consumer electronics equipment.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Cable ready consumer electronics equipment. 15... Unintentional Radiators § 15.118 Cable ready consumer electronics equipment. (a) All consumer electronics TV... provisions of this section. Consumer electronics TV receiving equipment that includes features intended for...
47 CFR 15.118 - Cable ready consumer electronics equipment.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 1 2014-10-01 2014-10-01 false Cable ready consumer electronics equipment. 15... Unintentional Radiators § 15.118 Cable ready consumer electronics equipment. (a) All consumer electronics TV... provisions of this section. Consumer electronics TV receiving equipment that includes features intended for...
47 CFR 15.118 - Cable ready consumer electronics equipment.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 1 2013-10-01 2013-10-01 false Cable ready consumer electronics equipment. 15... Unintentional Radiators § 15.118 Cable ready consumer electronics equipment. (a) All consumer electronics TV... provisions of this section. Consumer electronics TV receiving equipment that includes features intended for...
Lightweight, Flexible, Thin, Integrated Solar-Power Packs
NASA Technical Reports Server (NTRS)
Hanson, Robert R.
2004-01-01
Lightweight, flexible, thin, one-piece, solar-power packs are undergoing development. Each power pack of this type is a complete, modular, integrated power-supply system comprising three power subsystems that, in conventional practice, have been constructed as separate units and connected to each other by wires. These power packs are amenable to a variety of uses: For example, they could be laminated to the tops of tents and other shelters to provide or augment power for portable electronic equipment in the field, and they could be used as power sources for such small portable electronic systems as radio transceivers (including data relays and cellular telephones), laptop computers, video camcorders, and Global Positioning System receivers.
Differential phase acoustic microscope for micro-NDE
NASA Technical Reports Server (NTRS)
Waters, David D.; Pusateri, T. L.; Huang, S. R.
1992-01-01
A differential phase scanning acoustic microscope (DP-SAM) was developed, fabricated, and tested in this project. This includes the acoustic lens and transducers, driving and receiving electronics, scanning stage, scanning software, and display software. This DP-SAM can produce mechanically raster-scanned acoustic microscopic images of differential phase, differential amplitude, or amplitude of the time gated returned echoes of the samples. The differential phase and differential amplitude images provide better image contrast over the conventional amplitude images. A specially designed miniature dual beam lens was used to form two foci to obtain the differential phase and amplitude information of the echoes. High image resolution (1 micron) was achieved by applying high frequency (around 1 GHz) acoustic signals to the samples and placing two foci close to each other (1 micron). Tone burst was used in this system to obtain a good estimation of the phase differences between echoes from the two adjacent foci. The system can also be used to extract the V(z) acoustic signature. Since two acoustic beams and four receiving modes are available, there are 12 possible combinations to produce an image or a V(z) scan. This provides a unique feature of this system that none of the existing acoustic microscopic systems can provide for the micro-nondestructive evaluation applications. The entire system, including the lens, electronics, and scanning control software, has made a competitive industrial product for nondestructive material inspection and evaluation and has attracted interest from existing acoustic microscope manufacturers.
Laribi, Ouahiba; Malig, Brian; Sutherland-Ashley, Katherine; Broadwin, Rachel; Wieland, Walker; Salocks, Charles
2017-01-01
The California Medical Supervision program is designed to protect workers who regularly mix, load, or apply the highly toxic Category I and II organophosphates and carbamates from overexposure by monitoring cholinesterase (ChE) inhibition in plasma and red blood cells. Since January 2011, testing laboratories are required to report test results electronically to the California Department of Pesticide Regulation who shares it with the Office of Environmental Health Hazard Assessment for evaluation. The purpose of this study is to assess the utility of this reporting in evaluating the effectiveness of the Program for illness surveillance and prevention. From 2011 to 2013, we received more than 90 000 test results. Despite data gaps and data quality issues, we were able to perform spatial and temporal analyses and developed a screening tool to identify individuals potentially at risk of overexposure. The data analysis provided some evidence that the Program is effective in protecting agricultural workers handling the most toxic ChE-inhibiting pesticides even though it also identified some areas of potential concerns with individuals that appeared lacking corrective actions in the workplace in response to excessive ChE depressions and parts of the state with disproportionately at-risk individuals. However, changes to the electronic reporting are needed to more accurately identify tests related to the Program and therefore improve the utility of the data received. Moreover, data analysis also revealed that electronic reporting has its limitation in evaluating the Program.
A statistical approach to determining energetic outer radiation belt electron precipitation fluxes
NASA Astrophysics Data System (ADS)
Simon Wedlund, Mea; Clilverd, Mark A.; Rodger, Craig J.; Cresswell-Moorcock, Kathy; Cobbett, Neil; Breen, Paul; Danskin, Donald; Spanswick, Emma; Rodriguez, Juan V.
2014-05-01
Subionospheric radio wave data from an Antarctic-Arctic Radiation-Belt (Dynamic) Deposition VLF Atmospheric Research Konsortia (AARDDVARK) receiver located in Churchill, Canada, is analyzed to determine the characteristics of electron precipitation into the atmosphere over the range 3 < L < 7. The study advances previous work by combining signals from two U.S. transmitters from 20 July to 20 August 2010, allowing error estimates of derived electron precipitation fluxes to be calculated, including the application of time-varying electron energy spectral gradients. Electron precipitation observations from the NOAA POES satellites and a ground-based riometer provide intercomparison and context for the AARDDVARK measurements. AARDDVARK radiowave propagation data showed responses suggesting energetic electron precipitation from the outer radiation belt starting 27 July 2010 and lasting ~20 days. The uncertainty in >30 keV precipitation flux determined by the AARDDVARK technique was found to be ±10%. Peak >30 keV precipitation fluxes of AARDDVARK-derived precipitation flux during the main and recovery phase of the largest geomagnetic storm, which started on 4 August 2010, were >105 el cm-2 s-1 sr-1. The largest fluxes observed by AARDDVARK occurred on the dayside and were delayed by several days from the start of the geomagnetic disturbance. During the main phase of the disturbances, nightside fluxes were dominant. Significant differences in flux estimates between POES, AARDDVARK, and the riometer were found after the main phase of the largest disturbance, with evidence provided to suggest that >700 keV electron precipitation was occurring. Currently the presence of such relativistic electron precipitation introduces some uncertainty in the analysis of AARDDVARK data, given the assumption of a power law electron precipitation spectrum.
Code of Federal Regulations, 2014 CFR
2014-10-01
... services. Payment can be made electronically using the Commission's electronic filing and payment system...) Corres & 159 $1,130.00 CUT 3. Fixed Satellite Transmit/Receive Earth Stations: a. Initial Application... transmit/receive Earth Stations (2 meters or less operating in the 4/6 GHz frequency band): a. Lead...
Range gated strip proximity sensor
McEwan, T.E.
1996-12-03
A range gated strip proximity sensor uses one set of sensor electronics and a distributed antenna or strip which extends along the perimeter to be sensed. A micro-power RF transmitter is coupled to the first end of the strip and transmits a sequence of RF pulses on the strip to produce a sensor field along the strip. A receiver is coupled to the second end of the strip, and generates a field reference signal in response to the sequence of pulse on the line combined with received electromagnetic energy from reflections in the field. The sensor signals comprise pulses of radio frequency signals having a duration of less than 10 nanoseconds, and a pulse repetition rate on the order of 1 to 10 MegaHertz or less. The duration of the radio frequency pulses is adjusted to control the range of the sensor. An RF detector feeds a filter capacitor in response to received pulses on the strip line to produce a field reference signal representing the average amplitude of the received pulses. When a received pulse is mixed with a received echo, the mixing causes a fluctuation in the amplitude of the field reference signal, providing a range-limited Doppler type signature of a field disturbance. 6 figs.
Range gated strip proximity sensor
McEwan, Thomas E.
1996-01-01
A range gated strip proximity sensor uses one set of sensor electronics and a distributed antenna or strip which extends along the perimeter to be sensed. A micro-power RF transmitter is coupled to the first end of the strip and transmits a sequence of RF pulses on the strip to produce a sensor field along the strip. A receiver is coupled to the second end of the strip, and generates a field reference signal in response to the sequence of pulse on the line combined with received electromagnetic energy from reflections in the field. The sensor signals comprise pulses of radio frequency signals having a duration of less than 10 nanoseconds, and a pulse repetition rate on the order of 1 to 10 MegaHertz or less. The duration of the radio frequency pulses is adjusted to control the range of the sensor. An RF detector feeds a filter capacitor in response to received pulses on the strip line to produce a field reference signal representing the average amplitude of the received pulses. When a received pulse is mixed with a received echo, the mixing causes a fluctuation in the amplitude of the field reference signal, providing a range-limited Doppler type signature of a field disturbance.
GPS Antenna Data Needed : GPS Adjacent Band Compatibility Workshop Volpe Center, Cambridge MA
DOT National Transportation Integrated Search
2014-09-18
Topics. 1. Technical Objective: Receiver Antenna Mask and Electronics Data. 2. Definition of Receiver Antenna Mask. 3. Use of Receiver Antenna Mask. 4. Approaches to Generate the Antenna Mask. 5. Request for Receiver Antenna Data. 6. Next Steps.
Memory-built-in quantum cloning in a hybrid solid-state spin register
NASA Astrophysics Data System (ADS)
Wang, Weibin; Zu, Chong; He, Li; Zhang, Wengang; Duan, Luming
2015-05-01
As a way to circumvent the quantum no-cloning theorem, approximate quantum cloning protocols have received wide attention with remarkable applications. Copying of quantum states to memory qubits provides an important strategy for eavesdropping in quantum cryptography. We report an experiment that realizes cloning of quantum states from an electron spin to a nuclear spin in a hybrid solid-state spin register with near-optimal fidelity. The nuclear spin provides an ideal memory qubit at room temperature, which stores the cloned quantum states for a millisecond under ambient conditions, exceeding the lifetime of the original quantum state carried by the electron spin by orders of magnitude, and making it an ideal memory qubit. Our experiment is based on control of an individual nitrogen vacancy (NV) center in the diamond, which is a diamond defect that attracts strong interest in recent years with great potential for implementation of quantum information protocols.
NASA Astrophysics Data System (ADS)
Gok, Gokhan; Mosna, Zbysek; Arikan, Feza; Arikan, Orhan; Erdem, Esra
2016-07-01
Ionospheric observation is essentially accomplished by specialized radar systems called ionosondes. The time delay between the transmitted and received signals versus frequency is measured by the ionosondes and the received signals are processed to generate ionogram plots, which show the time delay or reflection height of signals with respect to transmitted frequency. The critical frequencies of ionospheric layers and virtual heights, that provide useful information about ionospheric structurecan be extracted from ionograms . Ionograms also indicate the amount of variability or disturbances in the ionosphere. With special inversion algorithms and tomographical methods, electron density profiles can also be estimated from the ionograms. Although structural pictures of ionosphere in the vertical direction can be observed from ionosonde measurements, some errors may arise due to inaccuracies that arise from signal propagation, modeling, data processing and tomographic reconstruction algorithms. Recently IONOLAB group (www.ionolab.org) developed a new algorithm for effective and accurate extraction of ionospheric parameters and reconstruction of electron density profile from ionograms. The electron density reconstruction algorithm applies advanced optimization techniques to calculate parameters of any existing analytical function which defines electron density with respect to height using ionogram measurement data. The process of reconstructing electron density with respect to height is known as the ionogram scaling or true height analysis. IONOLAB-RAY algorithm is a tool to investigate the propagation path and parameters of HF wave in the ionosphere. The algorithm models the wave propagation using ray representation under geometrical optics approximation. In the algorithm , the structural ionospheric characteristics arerepresented as realistically as possible including anisotropicity, inhomogenity and time dependence in 3-D voxel structure. The algorithm is also used for various purposes including calculation of actual height and generation of ionograms. In this study, the performance of electron density reconstruction algorithm of IONOLAB group and standard electron density profile algorithms of ionosondes are compared with IONOLAB-RAY wave propagation simulation in near vertical incidence. The electron density reconstruction and parameter extraction algorithms of ionosondes are validated with the IONOLAB-RAY results both for quiet anddisturbed ionospheric states in Central Europe using ionosonde stations such as Pruhonice and Juliusruh . It is observed that IONOLAB ionosonde parameter extraction and electron density reconstruction algorithm performs significantly better compared to standard algorithms especially for disturbed ionospheric conditions. IONOLAB-RAY provides an efficient and reliable tool to investigate and validate ionosonde electron density reconstruction algorithms, especially in determination of reflection height (true height) of signals and critical parameters of ionosphere. This study is supported by TUBITAK 114E541, 115E915 and Joint TUBITAK 114E092 and AS CR 14/001 projects.
Cross-Media Electronic Reporting Rule
Cross-Media Electronic Reporting Regulation (CROMERR) sets performance-based, technology-neutral standards for systems that states, tribes, and local governments use to receive electronic reports from facilities they regulate under EPA-authorized programs.
1992-11-18
Army. He is a graduate of Henderson State Univer- sity, Arkadelphia, Arkansas, and holds a master ofspend on financial management controls. Asset...supply system, he will receive credit receipts, and making monthly reconciliations with from the tactical unit financial management infor- activi ies at...obtain financial management rather than being added to the daily batch of requests information, and provide supply status information passed to the direct
Detection and Discrimination in One-Pass Using the OPTEMA Towed-Array
2014-11-01
pitch, roll , and yaw measurements for the OPTEMA sensor head. The IMU is co-located with the GPS receiver. OPTEMA sensor electronics include the...subtracted from subsequent data sets to isolate the anomaly response. In addition to a background subtraction, a transmitter current normalization is...the survey area. EM3DAcquire provides line following based on the sensor head GPS and IMU data. Using the line following display, the OPTEMA is
40 CFR 51.286 - Electronic reporting.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 2 2011-07-01 2011-07-01 false Electronic reporting. 51.286 Section 51... Requirements § 51.286 Electronic reporting. States that wish to receive electronic documents must revise the State Implementation Plan to satisfy the requirements of 40 CFR Part 3—(Electronic reporting). [70 FR...
40 CFR 51.286 - Electronic reporting.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 2 2012-07-01 2012-07-01 false Electronic reporting. 51.286 Section 51... Requirements § 51.286 Electronic reporting. States that wish to receive electronic documents must revise the State Implementation Plan to satisfy the requirements of 40 CFR Part 3—(Electronic reporting). [70 FR...
40 CFR 51.286 - Electronic reporting.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Electronic reporting. 51.286 Section 51... Requirements § 51.286 Electronic reporting. States that wish to receive electronic documents must revise the State Implementation Plan to satisfy the requirements of 40 CFR Part 3—(Electronic reporting). [70 FR...
40 CFR 51.286 - Electronic reporting.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 2 2013-07-01 2013-07-01 false Electronic reporting. 51.286 Section 51... Requirements § 51.286 Electronic reporting. States that wish to receive electronic documents must revise the State Implementation Plan to satisfy the requirements of 40 CFR Part 3—(Electronic reporting). [70 FR...
40 CFR 51.286 - Electronic reporting.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 2 2014-07-01 2014-07-01 false Electronic reporting. 51.286 Section 51... Requirements § 51.286 Electronic reporting. States that wish to receive electronic documents must revise the State Implementation Plan to satisfy the requirements of 40 CFR Part 3—(Electronic reporting). [70 FR...
Factors that impact nurses' use of electronic mail (e-mail).
Hughes, J A; Pakieser, R A
1999-01-01
As electronic applications are used increasingly in healthcare, nurses are being challenged to adopt them. Electronic mail (e-mail) is an electronic tool with general as well as healthcare uses. E-mail use may be an opportunity to learn a tool that requires skills similar to those used in other applications. This study aimed to identify barriers and facilitators that impact nurses' use of e-mail in the workplace. Data for this study were gathered using focus group methodology. Content analysis identified and labeled factors into seven major categories. Specific factors identified were generally consistent with those previously described in the literature as affecting use of computers in general. However, there were several additional factors identified that were not reported in other previous studies: lack of face-to-face communication, individual writing skills, recency of any educational experience, volume of mail received, password integrity, and technical support. Findings from this study provide information for any individual involved in introducing or updating an e-mail system in a healthcare environment.
Properties of Langmuir wave bursts associated with magnetic holes
NASA Technical Reports Server (NTRS)
MacDowall, R. J.; Lin, N.; Kellogg, P. J.; Phillips, J. L.; Neugebauer, M.; Balogh, A.; Forsyth, R. J.
1995-01-01
The radio and plasma wave receivers on the Ulysses spacecraft have detected thousands of short-duration bursts of waves at approximately the electron plasma frequency. These wave events believed to be Langmuir waves are usually less than approximately 5 minutes in duration. They occur in or at the boundaries of depletions in the magnetic field amplitude known as magnetic holes. Using the 16 sec time resolution provided by the plasma frequency receiver, it is possible to examine the density structure inside of magnetic holes. Even higher time resolutions are sometimes available from the radio receiver data. The Ulysses observations show that these wave bursts occur more frequently at high heliographic latitudes; the occurrence rates depend on both latitude and distance from the Sun. We review the statistics for the wave events, compare them to magnetic and plasma parameters, and review the reasons for the more frequent occurrence at high heliographic latitudes.
Implant for in-vivo parameter monitoring, processing and transmitting
Ericson, Milton N [Knoxville, TN; McKnight, Timothy E [Greenback, TN; Smith, Stephen F [London, TN; Hylton, James O [Clinton, TN
2009-11-24
The present invention relates to a completely implantable intracranial pressure monitor, which can couple to existing fluid shunting systems as well as other internal monitoring probes. The implant sensor produces an analog data signal which is then converted electronically to a digital pulse by generation of a spreading code signal and then transmitted to a location outside the patient by a radio-frequency transmitter to an external receiver. The implanted device can receive power from an internal source as well as an inductive external source. Remote control of the implant is also provided by a control receiver which passes commands from an external source to the implant system logic. Alarm parameters can be programmed into the device which are capable of producing an audible or visual alarm signal. The utility of the monitor can be greatly expanded by using multiple pressure sensors simultaneously or by combining sensors of various physiological types.
Implantable device for in-vivo intracranial and cerebrospinal fluid pressure monitoring
Ericson, Milton N.; McKnight, Timothy E.; Smith, Stephen F.; Hylton, James O.
2003-01-01
The present invention relates to a completely implantable intracranial pressure monitor, which can couple to existing fluid shunting systems as well as other internal monitoring probes. The implant sensor produces an analog data signal which is then converted electronically to a digital pulse by generation of a spreading code signal and then transmitted to a location outside the patient by a radio-frequency transmitter to an external receiver. The implanted device can receive power from an internal source as well as an inductive external source. Remote control of the implant is also provided by a control receiver which passes commands from an external source to the implant system logic. Alarm parameters can be programmed into the device which are capable of producing an audible or visual alarm signal. The utility of the monitor can be greatly expanded by using multiple pressure sensors simultaneously or by combining sensors of various physiological types.
NASA Astrophysics Data System (ADS)
Chiu, Ya-Ping; Huang, Bo-Chao; Shih, Min-Chuan; Huang, Po-Cheng; Chen, Chun-Wei
2015-09-01
Interfacial science has received much attention recently based on the development of state-of-the-art analytical tools that can create and manipulate the charge, spin, orbital, and lattice degrees of freedom at interfaces. Motivated by the importance of nanoscale interfacial science that governs device operation, we present a technique to probe the electronic characteristics of heterointerfaces with atomic resolution. In this work, the interfacial characteristics of heteroepitaxial structures are investigated and the fundamental mechanisms that pertain in these systems are elucidated through cross-sectional scanning tunneling microscopy (XSTM). The XSTM technique is employed here to directly observe epitaxial interfacial structures and probe local electronic properties with atomic-level capability. Scanning tunneling microscopy and spectroscopy experiments with atomic precision provide insight into the origin and spatial distribution of electronic properties across heterointerfaces. The first part of this report provides a brief description of the cleavage technique and spectroscopy analysis in XSTM measurements. The second part addresses interfacial electronic structures of several model heterostructures in current condensed matter research using XSTM. Topics to be discussed include high-κ‘s/III-V’s semiconductors, polymer heterojunctions, and complex oxide heterostructures, which are all material systems whose investigation using this technique is expected to benefit the research community. Finally, practical aspects and perspectives of using XSTM in interface science are presented.
NASA Astrophysics Data System (ADS)
Tarkeshian, R.; Vay, J. L.; Lehe, R.; Schroeder, C. B.; Esarey, E. H.; Feurer, T.; Leemans, W. P.
2018-04-01
Similarly to laser or x-ray beams, the interaction of sufficiently intense particle beams with neutral gases will result in the creation of plasma. In contrast to photon-based ionization, the strong unipolar field of a particle beam can generate a plasma where the electron population receives a large initial momentum kick and escapes, leaving behind unshielded ions. Measuring the properties of the ensuing Coulomb exploding ions—such as their kinetic energy distribution, yield, and spatial distribution—can provide information about the peak electric fields that are achieved in the electron beams. Particle-in-cell simulations and analytical models are presented for high-brightness electron beams of a few femtoseconds or even hundreds of attoseconds, and transverse beam sizes on the micron scale, as generated by today's free electron lasers. Different density regimes for the utilization as a potential diagnostics are explored, and the fundamental differences in plasma dynamical behavior for e-beam or photon-based ionization are highlighted. By measuring the dynamics of field-induced ions for different gas and beam densities, a lower bound on the beam charge density can be obtained in a single shot and in a noninvasive way. The exponential dependency of the ionization yield on the beam properties can provide unprecedented spatial and temporal resolution, at the submicrometer and subfemtosecond scales, respectively, offering a practical and powerful approach to characterizing beams from accelerators at the frontiers of performance.
NASA Astrophysics Data System (ADS)
Savastano, Giorgio; Komjathy, Attila; Verkhoglyadova, Olga; Wei, Yong; Mazzoni, Augusto; Crespi, Mattia
2017-04-01
Tsunamis can produce gravity waves that propagate up to the ionosphere generating disturbed electron densities in the E and F regions. These ionospheric disturbances are studied in detail using ionospheric total electron content (TEC) measurements collected by continuously operating ground-based receivers from the Global Navigation Satellite Systems (GNSS). Here, we present results using a new approach, named VARION (Variometric Approach for Real-Time Ionosphere Observation), and for the first time, we estimate slant TEC (sTEC) variations in a real-time scenario from GPS and Galileo constellations. Specifically, we study the 2016 New Zealand tsunami event using GNSS receivers with multi-constellation tracking capabilities located in the Pacific region. We compare sTEC estimates obtained using GPS and Galileo constellations. The efficiency of the real-time sTEC estimation using the VARION algorithm has been demonstrated for the 2012 Haida Gwaii tsunami event. TEC variations induced by the tsunami event are computed using 56 GPS receivers in Hawai'i. We observe TEC perturbations with amplitudes up to 0.25 TEC units and traveling ionospheric disturbances moving away from the epicenter at a speed of about 316 m/s. We present comparisons with the real-time tsunami model MOST (Method of Splitting Tsunami) provided by the NOAA Center for Tsunami Research. We observe variations in TEC that correlate well in time and space with the propagating tsunami waves. We conclude that the integration of different satellite constellations is a crucial step forward to increasing the reliability of real-time tsunami detection systems using ground-based GNSS receivers as an augmentation to existing tsunami early warning systems.
Popovich, Michael; Altstadter, Brandy; Popovich, Lara Hargraves
2016-01-01
The Health Information Technology for Economic and Clinical Health (HITECH) Act encourages health information exchange between clinical care and public health through Meaningful Use measures. Meaningful Use specifically identifies objectives to support a number of public health programs including immunizations, cancer registries, syndromic surveillance, and disease case reports. The objective is to improve public and population health. Stage 2 of Meaningful Use focused on compliance to sending of information to public health. The next phase focuses on bi-directional information exchange to support immunization intelligence and to empower providers, pharmacists, and the consumer. The HITECH Act Stage 2 initiative provided incentive and motivation for healthcare providers to encourage their Electronic Medical Record (EMR) vendors to implement data exchanges with public health, with the expected result being timely awareness of health risks. The empowerment nugget in the HITECH Act is not in the compliance reporting to public health. The nugget is the ability for a provider to receive relevant information on the patient or consumer currently in front of them or to those they will connect to through their outreach efforts. The ability for public health to retain current immunization records of individuals from a variety of providers supports their program goals to increase immunization rates and mitigate the risk of vaccine-preventable disease (VPD). The ability for providers to receive at the point of service more complete immunization histories integrated with decision support enhances their delivery of care, thereby reducing the risk of VPD to their patients. Indirectly payers benefit through healthcare cost savings and when the focus is expanded from a health model to a business model, there are significant return on investment (ROI) opportunities that exponentially increase the value of a bi-directional immunization data exchange. This paper will provide descriptions of case examples to demonstrate the value of electronic data exchanges when pharmacy immunization providers and public health work together.
Neutral beamline with ion energy recovery based on magnetic blocking of electrons
Stirling, William L.
1982-01-01
A neutral beamline generator with energy recovery of the full-energy ion ponent of the beam based on magnetic blocking of electrons is provided. Ions from a positive ion source are accelerated to the desired beam energy from a slightly positive potential level with respect to ground through a neutralizer cell by means of a negative acceleration voltage. The unneutralized full-energy ion component of the beam exiting the neutralizer are retarded and slightly deflected and the electrons in the neutralizer are blocked by a magnetic field generated transverse to the beamline. An electron collector in the form of a coaxial cylinder surrounding and protruding axial a few centimeters beyond the neutralizer exit terminates the electrons which exit the neutralizer in an E x B drift to the collector when the collector is biased a few hundred volts positive with respect to the neutralizer voltage. The neutralizer is operated at the negative acceleration voltage, and the deflected full energy ions are decelerated and the charge collected at ground potential thereby expending none of their energy received from the acceleration power supply.
Use of an electronic problem list by primary care providers and specialists.
Wright, Adam; Feblowitz, Joshua; Maloney, Francine L; Henkin, Stanislav; Bates, David W
2012-08-01
Accurate patient problem lists are valuable tools for improving the quality of care, enabling clinical decision support, and facilitating research and quality measurement. However, problem lists are frequently inaccurate and out-of-date and use varies widely across providers. Our goal was to assess provider use of an electronic problem list and identify differences in usage between medical specialties. Chart review of a random sample of 100,000 patients who had received care in the past two years at a Boston-based academic medical center. Counts were collected of all notes and problems added for each patient from 1/1/2002 to 4/30/2010. For each entry, the recording provider and the clinic in which the entry was recorded was collected. We used the Healthcare Provider Taxonomy Code Set to categorize each clinic by specialty. We analyzed the problem list use across specialties, controlling for note volume as a proxy for visits. A total of 2,264,051 notes and 158,105 problems were recorded in the electronic medical record for this population during the study period. Primary care providers added 82.3% of all problems, despite writing only 40.4% of all notes. Of all patients, 49.1% had an assigned primary care provider (PCP) affiliated with the hospital; patients with a PCP had an average of 4.7 documented problems compared to 1.5 problems for patients without a PCP. Primary care providers were responsible for the majority of problem documentation; surgical and medical specialists and subspecialists recorded a disproportionately small number of problems on the problem list.
SPECTRE (www.noveltis.fr/spectre): a web Service for Ionospheric Products
NASA Astrophysics Data System (ADS)
Jeansou, E.; Crespon, F.; Garcia, R.; Helbert, J.; Moreaux, G.; Lognonne, P.
2005-12-01
The dense GPS networks developed for geodesic applications appear to be very efficient ionospheric sensors because of interaction between plasma and electromagnetic waves. Indeed, the dual frequency receivers provide data from which the Slant Total Electron Content (STEC) can be easily extracted to compute Vertical Total Electron Content (VTEC) maps. The SPECTRE project, Service and Products for ionospheric Electron Content and Tropospheric Refractivity over Europe, is currently a pre-operational service providing VTEC maps with high time and space resolution after 3 days time delay (http://www.noveltis.fr/spectre and http://ganymede.ipgp.jussieu.fr/spectre). This project is a part of SWENET, SpaceWeather European Network, initiated by the European Space Agency. The SPECTRE data products are useful for many applications. We will present these applications in term of interest for the scientific community with a special focus on spaceweather and transient ionospheric perturbations related to Earthquakes. Moreover, the pre-operational extensions of SPECTRE to the californian (SCIGN/BARD) and japanese (GEONET) dense GPS networks will be presented. Then the method of 3D tomography of the electron density from GPS data will be presented and its resolution discussed. The expected improvements of the 3D tomographic images by new tomographic reconstruction algorithms and by the advent of the Galileo system will conclude the presentation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lim, Young Soo, E-mail: yslim@pknu.ac.kr, E-mail: wsseo@kicet.re.kr, E-mail: pmoka@lgchem.com; Park, Kwan-Ho; Tak, Jang Yeul
2016-03-21
Among many kinds of thermoelectric materials, CoSb{sub 3} has received exceptional attention for automotive waste heat recovery. Its cage structure provides an ideal framework for the realization of phonon-glass electron-crystal strategy, and there have been numerous reports on the enhanced thermoelectric performance through the independent control of the thermal and electrical conductivity by introducing fillers into its cage sites. Herein, we report colligative thermoelectric transport properties in n-type CoSb{sub 3} from the viewpoint of “guest electrons in a host lattice.” Both the Seebeck coefficient and the charge transport properties are fundamentally determined by the concentration of the guest electrons, whichmore » are mostly donated by the fillers, in the conduction band of the host CoSb{sub 3}. Comparing this observation to our previous results, colligative relations for both the Seebeck coefficient and the mobility were deduced as functions of the carrier concentration, and thermoelectric transport constants were defined to predict the power factor in filled CoSb{sub 3}. This discovery not only increases the degree of freedom for choosing a filler but also provides the predictability of power factor in designing and engineering the n-type filled CoSb{sub 3} materials.« less
Thermoelectronic laser energy conversion for power transmission in space
NASA Technical Reports Server (NTRS)
Britt, E. J.; Yuen, C.
1977-01-01
Long distance transmission of power in space by means of laser beams is an attractive concept because of the very narrow beam divergence. Such a system requires efficient means to both generate the laser beam and to convert the light energy in the beam into useful electric output at the receiver. A plasma-type device known as a Thermo-Electronic Laser Energy Converter (TELEC) has been studied as a method of converting a 10.6 micron CO2 laser beam into electric power. In the TELEC process, electromagnetic radiation is absorbed directly in the plasma electrons producing a high electron temperature. The energetic electrons diffuse out of the plasma striking two electrodes with different areas. Since more electrons are collected by the larger electrode there is a net transport of current, and an EMF is generated in the external circuit. The smaller electrode functions as an electron emitter to provide continuity of the current. Waste heat is rejected from the large electrode. A design for a TELEC system with an input 1 MW laser beam was developed as part of the study. The calculated performance of the system showed an overall efficiency of about 42%.
Applications and Advances in Electronic-Nose Technologies
Wilson, Alphus D.; Baietto, Manuela
2009-01-01
Electronic-nose devices have received considerable attention in the field of sensor technology during the past twenty years, largely due to the discovery of numerous applications derived from research in diverse fields of applied sciences. Recent applications of electronic nose technologies have come through advances in sensor design, material improvements, software innovations and progress in microcircuitry design and systems integration. The invention of many new e-nose sensor types and arrays, based on different detection principles and mechanisms, is closely correlated with the expansion of new applications. Electronic noses have provided a plethora of benefits to a variety of commercial industries, including the agricultural, biomedical, cosmetics, environmental, food, manufacturing, military, pharmaceutical, regulatory, and various scientific research fields. Advances have improved product attributes, uniformity, and consistency as a result of increases in quality control capabilities afforded by electronic-nose monitoring of all phases of industrial manufacturing processes. This paper is a review of the major electronic-nose technologies, developed since this specialized field was born and became prominent in the mid 1980s, and a summarization of some of the more important and useful applications that have been of greatest benefit to man. PMID:22346690
Privacy protection for patients with substance use problems.
Hu, Lianne Lian; Sparenborg, Steven; Tai, Betty
2011-01-01
Many Americans with substance use problems will have opportunities to receive coordinated health care through the integration of primary care and specialty care for substance use disorders under the Patient Protection and Affordable Care Act of 2010. Sharing of patient health records among care providers is essential to realize the benefits of electronic health records. Health information exchange through meaningful use of electronic health records can improve health care safety, quality, and efficiency. Implementation of electronic health records and health information exchange presents great opportunities for health care integration, but also makes patient privacy potentially vulnerable. Privacy issues are paramount for patients with substance use problems. This paper discusses major differences between two federal privacy laws associated with health care for substance use disorders, identifies health care problems created by privacy policies, and describes potential solutions to these problems through technology innovation and policy improvement.
Privacy protection for patients with substance use problems
Hu, Lianne Lian; Sparenborg, Steven; Tai, Betty
2011-01-01
Many Americans with substance use problems will have opportunities to receive coordinated health care through the integration of primary care and specialty care for substance use disorders under the Patient Protection and Affordable Care Act of 2010. Sharing of patient health records among care providers is essential to realize the benefits of electronic health records. Health information exchange through meaningful use of electronic health records can improve health care safety, quality, and efficiency. Implementation of electronic health records and health information exchange presents great opportunities for health care integration, but also makes patient privacy potentially vulnerable. Privacy issues are paramount for patients with substance use problems. This paper discusses major differences between two federal privacy laws associated with health care for substance use disorders, identifies health care problems created by privacy policies, and describes potential solutions to these problems through technology innovation and policy improvement. PMID:24474860
Electronic communication preferences among mothers in the neonatal intensive care unit.
Weems, M F; Graetz, I; Lan, R; DeBaer, L R; Beeman, G
2016-11-01
Mobile communication with the medical-care team has the potential to decrease stress among parents of infants admitted to the neonatal intensive care unit (NICU). We assessed mobile use and communication preferences in a population of urban minority NICU mothers. A 30-question English language survey was administered to mothers of NICU patients. The survey was completed by 217 mothers, 75% were Black, and 75% reported annual household income below $20 000. Only 56% had a computer with Internet access at home, but 79% used smartphones. Most (79%) have searched the Internet for health information in the past year. Receiving electronic messages about their babies was viewed favorably, and text messaging was the preferred platform. The majority of mothers felt electronic messaging would improve communication but should not replace verbal communication. Mobile communication is used widely in this population of NICU mothers and could potentially improve provider-parent communication and reduce parental stress.
Buset, Jonathan M; El-Sahn, Ziad A; Plant, David V
2012-06-18
We demonstrate an improved overlapped-subcarrier multiplexed (O-SCM) WDM PON architecture transmitting over a single feeder using cost sensitive intensity modulation/direct detection transceivers, data re-modulation and simple electronics. Incorporating electronic equalization and Reed-Solomon forward-error correction codes helps to overcome the bandwidth limitation of a remotely seeded reflective semiconductor optical amplifier (RSOA)-based ONU transmitter. The O-SCM architecture yields greater spectral efficiency and higher bit rates than many other SCM techniques while maintaining resilience to upstream impairments. We demonstrate full-duplex 5 Gb/s transmission over 20 km and analyze BER performance as a function of transmitted and received power. The architecture provides flexibility to network operators by relaxing common design constraints and enabling full-duplex operation at BER ∼ 10(-10) over a wide range of OLT launch powers from 3.5 to 8 dBm.
A polymer/semiconductor write-once read-many-times memory
NASA Astrophysics Data System (ADS)
Möller, Sven; Perlov, Craig; Jackson, Warren; Taussig, Carl; Forrest, Stephen R.
2003-11-01
Organic devices promise to revolutionize the extent of, and access to, electronics by providing extremely inexpensive, lightweight and capable ubiquitous components that are printed onto plastic, glass or metal foils. One key component of an electronic circuit that has thus far received surprisingly little attention is an organic electronic memory. Here we report an architecture for a write-once read-many-times (WORM) memory, based on the hybrid integration of an electrochromic polymer with a thin-film silicon diode deposited onto a flexible metal foil substrate. WORM memories are desirable for ultralow-cost permanent storage of digital images, eliminating the need for slow, bulky and expensive mechanical drives used in conventional magnetic and optical memories. Our results indicate that the hybrid organic/inorganic memory device is a reliable means for achieving rapid, large-scale archival data storage. The WORM memory pixel exploits a mechanism of current-controlled, thermally activated un-doping of a two-component electrochromic conducting polymer.
29 CFR 2520.104b-1 - Disclosure.
Code of Federal Regulations, 2011 CFR
2011-07-01
... documents furnished in electronic form at any location where the participant is reasonably expected to... or non-electronic form, to receiving documents through electronic media and has not withdrawn such consent; (B) In the case of documents to be furnished through the Internet or other electronic...
29 CFR 2520.104b-1 - Disclosure.
Code of Federal Regulations, 2014 CFR
2014-07-01
... documents furnished in electronic form at any location where the participant is reasonably expected to... or non-electronic form, to receiving documents through electronic media and has not withdrawn such consent; (B) In the case of documents to be furnished through the Internet or other electronic...
29 CFR 2520.104b-1 - Disclosure.
Code of Federal Regulations, 2012 CFR
2012-07-01
... documents furnished in electronic form at any location where the participant is reasonably expected to... or non-electronic form, to receiving documents through electronic media and has not withdrawn such consent; (B) In the case of documents to be furnished through the Internet or other electronic...
29 CFR 2520.104b-1 - Disclosure.
Code of Federal Regulations, 2013 CFR
2013-07-01
... documents furnished in electronic form at any location where the participant is reasonably expected to... or non-electronic form, to receiving documents through electronic media and has not withdrawn such consent; (B) In the case of documents to be furnished through the Internet or other electronic...
Code of Federal Regulations, 2010 CFR
2010-01-01
... identity when filing documents and serving participants electronically through the E-Filing system, and... transmitted electronically from the E-Filing system to the submitter confirming receipt of electronic filing... presentation of the docket and a link to its files. E-Filing System means an electronic system that receives...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ren, Shangjie; Department of Radiation Oncology, Stanford University School of Medicine, Palo Alto, California; Hara, Wendy
Purpose: To develop a reliable method to estimate electron density based on anatomic magnetic resonance imaging (MRI) of the brain. Methods and Materials: We proposed a unifying multi-atlas approach for electron density estimation based on standard T1- and T2-weighted MRI. First, a composite atlas was constructed through a voxelwise matching process using multiple atlases, with the goal of mitigating effects of inherent anatomic variations between patients. Next we computed for each voxel 2 kinds of conditional probabilities: (1) electron density given its image intensity on T1- and T2-weighted MR images; and (2) electron density given its spatial location in a referencemore » anatomy, obtained by deformable image registration. These were combined into a unifying posterior probability density function using the Bayesian formalism, which provided the optimal estimates for electron density. We evaluated the method on 10 patients using leave-one-patient-out cross-validation. Receiver operating characteristic analyses for detecting different tissue types were performed. Results: The proposed method significantly reduced the errors in electron density estimation, with a mean absolute Hounsfield unit error of 119, compared with 140 and 144 (P<.0001) using conventional T1-weighted intensity and geometry-based approaches, respectively. For detection of bony anatomy, the proposed method achieved an 89% area under the curve, 86% sensitivity, 88% specificity, and 90% accuracy, which improved upon intensity and geometry-based approaches (area under the curve: 79% and 80%, respectively). Conclusion: The proposed multi-atlas approach provides robust electron density estimation and bone detection based on anatomic MRI. If validated on a larger population, our work could enable the use of MRI as a primary modality for radiation treatment planning.« less
QPPM receiver for free-space laser communications
NASA Technical Reports Server (NTRS)
Budinger, J. M.; Mohamed, J. H.; Nagy, L. A.; Lizanich, P. J.; Mortensen, D. J.
1994-01-01
A prototype receiver developed at NASA Lewis Research Center for direct detection and demodulation of quaternary pulse position modulated (QPPM) optical carriers is described. The receiver enables dual-channel communications at 325-Megabits per second (Mbps) per channel. The optical components of the prototype receiver are briefly described. The electronic components, comprising the analog signal conditioning, slot clock recovery, matched filter and maximum likelihood data recovery circuits are described in more detail. A novel digital symbol clock recovery technique is presented as an alternative to conventional analog methods. Simulated link degradations including noise and pointing-error induced amplitude variations are applied. The bit-error-rate performance of the electronic portion of the prototype receiver under varying optical signal-to-noise power ratios is found to be within 1.5-dB of theory. Implementation of the receiver as a hybrid of analog and digital application specific integrated circuits is planned.
Communications/Electronics Receiver Performance Degradation Handbook (Second Edition)
1975-08-01
receiver to another in the Rf and IF filter characteristics modify the transfer of inter- forence power through the receiver to the IF output, and so the...modulation system the transmitted and received messages arce in general different bemaus* of small inte, forence or noise perturbations. The probability of
Chiu, T.; Wolfe, S.; Magid, S.
2015-01-01
Summary Objectives The authors investigated the impact of computerized provider order entry (CPOE) on the delivery times of analgesia and subsequent patient outcomes. We hypothesized that patients would report less pain and use less pain medications compared with the previous paper-based system. Methods Two groups of patients after a total hip (THA) or knee arthroplasty (TKA) were retrospectively compared: one comprising 106 patients when the paper-based ordering system was in effect (conventional group), and one comprising 96 patients after CPOE was installed (electronic group). All patients received a regional anaesthetic at surgery (combined spinal-epidural). TKA patients also received a single-injection femoral nerve block. After transfer to the postoperative anaesthesia care unit (PACU), a patient-controlled epidural analgesia (PCEA) infusion was initiated. The following data was collected from the PACU record: time to initiation of analgesia, visual analog scale (VAS) pain scores at initiation of analgesia and hourly for the first postoperative day (POD), volume of pain medication used, length of stay (LOS) in the PACU and the hospital. Results The time to initiation of analgesia from arrival in the PACU was significantly lower in the electronic group compared to the conventional group (24.5 ± 28.3 minutes vs. 51.1 ± 26.2 minutes; mean ± SD, p < 0.001), as were VAS pain scores (0.82 ± 1.08 vs. 1.5 ± 1.52, p < 0.001) and the volume of PCEA needed to control pain (27.9 ± 20.2 ml vs. 34.8 ± 20.3 ml, p = 0.001) at 4 hours postoperatively. PACU LOS and hospital LOS did not significantly differ in the two groups. Conclusions After implementation of CPOE, patients received their postoperative analgesia faster, had less pain, and required less medication. PMID:26448800
Measuring Outcomes of Digital Technology-Assisted Nursing Postpartum: A Randomized Controlled Trial.
Mccarter, Deborah E; Demidenko, Eugene; Hegel, Mark T
2018-05-17
To determine if delivering electronic messages from nurses during the first six months postpartum is feasible, acceptable and effective in improving mood and decreasing parenting stress. Competing demands during the postpartum hospitalization make focused time for nurses to provide education and support difficult. Unmet needs following discharge may increase the incidence of postpartum depression. Untreated depression negatively affects families, especially for vulnerable women with limited access to health care. This is a longitudinal cohort study in three phases. Feasibility and acceptability were assessed during Phases 1 & 2. Phase 3 is a randomized controlled trial (RCT) with three conditions. This protocol was approved by the Institutional Review Board of the maternity hospital on 12 May 2015 and reviewed annually. Women are enrolled during the maternity hospitalization, after which randomization occurs. The control group receives usual care. Intervention I participants receive a standardized electronic message four times/week for six months postpartum. Intervention II participants receive the messages and the option to request a call from a nurse. Electronic surveys at 3 weeks, 3 months and 6 months postpartum measure depressive symptoms using the Edinburgh Postnatal Depression Scale and parenting stress using the Parenting Stress Index-Short form. Patient satisfaction, nursing time and expertise required are also measured. Phase 1 and 2 have demonstrated the intervention is feasible and acceptable to women. Phase 3 enrollment is completed, and the last follow-up surveys were emailed to participants in February 2018. Results will help inform efforts to continue nursing care after hospital discharge. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Sittig, Dean F
2003-01-01
Background Email is the most important mechanism introduced since the telephone for developing interpersonal relationships. This study was designed to provide insight into how patients are using email to request information or services from their healthcare providers. Methods Following IRB approval, we reviewed all electronic mail (e-mail) messages sent between five study clinicians and their patients over a one-month period. We used a previously described taxonomy of patient requests to categorize all patient requests contained in the messages. We measured message volume, frequency, length and response time for all messages sent to and received by these clinicians. Results On average the 5 physicians involved in this study received 40 messages per month, each containing approximately 139 words. Replies sent by the physicians contained 39 words on average and 59.4% of them were sent within 24 hours. Patients averaged 1 request per message. Requests for information on medications or treatments, specific symptoms or diseases, and requests for actions regarding medications or treatments accounted for 75% of all requests. Physicians fulfilled 80.2% of all these requests. Upon comparison of these data to that obtained from traditional office visits, it appears that the potential exists for email encounters to substitute for some percentage of office visits. Conclusion Electronic messaging is an important method for physicians and patients to communicate and further develop their relationship. While many physicians worry that either the number or length of messages from their patients will overwhelm them, there is no evidence to support this. In fact, the evidence suggests that many patient requests, formerly made over the telephone or during office visits, can be addressed via email thus potentially saving both patients and physicians time. PMID:14519206
Emergency access to protected health records.
Künzi, Julien; Koster, Paul; Petković, Milan
2009-01-01
Digital Rights Management (DRM) schemes are receiving increased attention in the healthcare domain for the protection of sensitive health records as they offer security against insider attacks and advance protection features such as usage control. However, to be accepted by health care providers, a DRM solution has to fulfill specific healthcare requirements including emergency access. In this paper, we propose such DRM solution that can be deployed in highly distributed environments of electronic or personal health record infrastructures.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-23
... INTERNATIONAL TRADE COMMISSION [Docket No 2956] Certain Consumer Electronics With Display and... the U.S. International Trade Commission has received a complaint entitled Certain Consumer Electronics... consumer electronics with display and processing capabilities. The complaint names as respondents Panasonic...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-30
... INTERNATIONAL TRADE COMMISSION [Docket No. 2904] Certain Wireless Consumer Electronics Devices and.... International Trade Commission has received a complaint entitled Certain Wireless Consumer Electronics Devices... importation, and the sale within the United States after importation of certain wireless consumer electronics...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-09
...-126] Basic Service Tier Encryption Compatibility Between Cable Systems and Consumer Electronics... between consumer electronics equipment (such as digital television sets) and newly encrypted cable service... Act''), Congress sought to make sure that consumer electronics equipment could receive cable...
Tonnonchiang, Siriporn; Sritongkul, Nopamon; Chaudakshetrin, Pachee; Tuntawiroon, Malulee
2016-02-01
Thyroid cancer patients treated with 1-131 are potential source of radiation exposure to relatives who are knowingly and willingly exposed to ionizing radiation as a result of providing comfort to patients undergoing I-131 therapy. This study aims to determine radiation dose received by relatives who care for non self-supporting 1-131 patients at Siriraj Hospital. Twenty caregivers of 20 patients underwent I-131 therapy for thyroid cancer with a standard protocol were given specific instructions with regard to radiation safety and provided with electronic digital dosimeter to continuously measure radiation dose received on daily basis, three days in the hospital. On the day patient is released, thyroid uptake estimates were performed to assess internal radiation dose received by caregivers. The 3-day accumulative doses to caregivers to patients receiving 150 mCi (n = 11) and 200 mCi (n = 9) of I-131 ranged from 37 to 333 uSv and 176 to 1,920 pSv respectively depending on the level of supports required. Thyroid uptake estimates in all caregivers were undetectable. Dosimeter indicated a maximum whole-body dose of1.92 mSv was more than the public dose limit of] mSv but within the dose constraint of 5 mSv for caregivers. Radiation dose to caregivers of a non self-supporting hospitalized patient undergoing 1-131 therapy were well below the limits recommended by the ICRP. The patients can be comforted with confidence that dose to caregivers will be less than the limit. This study provides guidance for medical practitioners to obtain practical radiation safety concerns associated with hospitalized patients receiving I-131 therapy especially when patient needs assistance.
NASA Astrophysics Data System (ADS)
Li, Min; Yuan, Yunbin; Wang, Ningbo; Liu, Teng; Chen, Yongchang
2017-12-01
Care should be taken to minimize the adverse impact of differential code biases (DCBs) on global navigation satellite systems (GNSS)-derived ionospheric information determinations. For the sake of convenience, satellite and receiver DCB products provided by the International GNSS Service (IGS) are treated as constants over a period of 24 h (Li et al. (2014)). However, if DCB estimates show remarkable intra-day variability, the DCBs estimated as constants over 1-day period will partially account for ionospheric modeling error; in this case DCBs will be required to be estimated over shorter time period. Therefore, it is important to further gain insight into the short-term variation characteristics of receiver DCBs. In this contribution, the IGS combined global ionospheric maps and the German Aerospace Center (DLR)-provided satellite DCBs are used in the improved method to determine the multi-GNSS receiver DCBs with an hourly time resolution. The intra-day stability of the receiver DCBs is thereby analyzed in detail. Based on 1 month of data collected within the multi-GNSS experiment of the IGS, a good agreement within the receiver DCBs is found between the resulting receiver DCB estimates and multi-GNSS DCB products from the DLR at a level of 0.24 ns for GPS, 0.28 ns for GLONASS, 0.28 ns for BDS, and 0.30 ns for Galileo. Although most of the receiver DCBs are relatively stable over a 1-day period, large fluctuations (more than 9 ns between two consecutive hours) within the receiver DCBs can be found. We also demonstrate the impact of the significant short-term variations in receiver DCBs on the extraction of ionospheric total electron content (TEC), at a level of 12.96 TECu (TEC unit). Compared to daily receiver DCB estimates, the hourly DCB estimates obtained from this study can reflect the short-term variations of the DCB estimates more dedicatedly. The main conclusion is that preliminary analysis of characteristics of receiver DCB variations over short-term intervals should be finished prior to estimate daily multi-GNSS receiver DCB products.
Lefbom, Bonnie K; Peckens, Neal K
2016-07-01
OBJECTIVE To assess the effects of in-person collaborative care by primary care veterinarians (pcDVMs) and board-certified veterinary cardiologists (BCVCs) on survival time of dogs after onset of congestive heart failure (CHF) and on associated revenue for the attending pcDVMs. DESIGN Retrospective cohort study. ANIMALS 26 small-breed dogs treated for naturally occurring CHF secondary to myxomatous mitral valve disease at a multilocation primary care veterinary hospital between 2008 and 2013. PROCEDURES Electronic medical records were reviewed to identify dogs with confirmed CHF secondary to myxomatous mitral valve disease and collect information on patient care, survival time, and pcDVM revenue. Data were compared between dogs that received collaborative care from the pcDVM and a BCVC and dogs that received care from the pcDVM alone. RESULTS Dogs that received collaborative care had a longer median survival time (254 days) than did dogs that received care from the pcDVM alone (146 days). A significant positive correlation was identified between pcDVM revenue and survival time for dogs that received collaborative care (ie, the longer the dog survived, the greater the pcDVM revenue generated from caring for that patient). CONCLUSIONS AND CLINICAL RELEVANCE Findings suggested that collaborative care provided to small-breed dogs with CHF by a BCVC and pcDVM could result in survival benefits for affected dogs and increased revenue for pcDVMs, compared with care provided by a pcDVM alone.
How complete are immunization registries? The Philadelphia story.
Kolasa, Maureen S; Chilkatowsky, Andrew P; Clarke, Kevin R; Lutz, James P
2006-01-01
To assess accuracy and completeness of Philadelphia, Pa, registry data among children served by providers in areas at risk for underimmunization. Philadelphia's Department of Public Health selected a simple random sample of 45 children age 19-35 months (or all children age 19-35 months if there were <45 children in the practice) from each of 30 private practices receiving government-funded vaccine and located in zip codes where children are at risk for underimmunization. Chart and registry data were compared with determine the proportion of children missing from the registry and assess differences in immunization coverage. Of 620 children reviewed, 567 (92%) were in the registry. Significant differences (P < .05) were observed in immunization coverage for 4 diphtheria-tetanus-acellular pertussis vaccinations, 3 polio vaccinations, 1 measles-mumps-rubella vaccination, and 3 Haemophilus influenzae type b vaccinations between the chart (80% coverage) and registry (62% coverage). Providers submitting electronic medical records or directly transferring electronic data to the registry had significantly more children in the registry and higher registry-reported immunization coverage than those whose data were entered from billing records or log forms. All practice types experienced difficulties in transferring complete data to the registry. Although 92% of study children were in the registry, immunization coverage was significantly lower when registry data were compared with chart data. Because electronic medical records and direct electronic data transfer resulted in more complete registry data, these methods should be encouraged in linking providers with immunization registries.
Development of a Cancer Care Summary Through the Electronic Health Record.
Carr, Laurie L; Zelarney, Pearlanne; Meadows, Sarah; Kern, Jeffrey A; Long, M Bronwyn; Kern, Elizabeth
2016-02-01
Our objective was to improve communication concerning lung cancer patients by developing and distributing a Cancer Care Summary that would provide clinically useful information about the patient's diagnosis and care to providers in diverse settings. We designed structured, electronic forms for the electronic health record (EHR), detailing tumor staging, classification, and treatment. To ensure completeness and accuracy of the information, we implemented a data quality cycle, composed of reports that are reviewed by oncology clinicians. The data from the EHR forms are extracted into a structured query language database system on a daily basis, from which the Summaries are derived. We conducted focus groups regarding the utility, format, and content of the Summary. Cancer Care Summaries are automatically generated 4 months after a patient's date of diagnosis, then every 6 months for those receiving treatment, and on an as-needed basis for urgent care or hospital admission. The product of our improvement project is the Cancer Care Summary. To date, 102 individual patient Summaries have been generated. These documents are automatically entered into the National Jewish Health (NJH) EHR, attached to correspondence to primary care providers, available to patients as electronic documents on the NJH patient portal, and faxed to emergency departments and admitting physicians on patient evaluation. We developed a sustainable tool to improve cancer care communication. The Cancer Care Summary integrates information from the EHR in a timely manner and distributes the information through multiple avenues. Copyright © 2016 by American Society of Clinical Oncology.
Clark, Laura; Ronaldson, Sarah; Dyson, Lisa; Hewitt, Catherine; Torgerson, David; Adamson, Joy
2015-12-01
To assess the effectiveness of sending electronic prompts to randomized controlled trial participants to return study questionnaires. A "trial within a trial" embedded within a study determining the effectiveness of chronic obstructive pulmonary disease (DOC) screening on smoking cessation. Those participants taking part in DOC who provided a mobile phone number and/or an electronic mail address were randomized to either receive an electronic prompt or no electronic prompt to return a study questionnaire. The results were combined with two previous studies in a meta-analysis. A total of 437 participants were randomized: 226 to the electronic prompt group and 211 to the control group. A total of 285 (65.2%) participants returned the follow-up questionnaire: 157 (69.5%) in the electronic prompt group and 128 (60.7%) in the control group [difference 8.8%; 95% confidence interval (CI): -0.11%, 17.7%; P = 0.05]. The mean time to response was 23 days in the electronic prompt group and 33 days in the control group (hazard ratio = 1.27; 95% CI: 1.105, 1.47). The meta-analysis of all three studies showed an increase in response rate of 7.1% (95% CI: 0.8%, 13.3%). The use of electronic prompts increased response rates and reduces the time to response. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Cho, Young Y.; Chang, Cheng-Chung; Wang, Lihong V.; Zou, Jun
2015-03-01
To achieve real-time photoacoustic tomography (PAT), massive transducer arrays and data acquisition (DAQ) electronics are needed to receive the PA signals simultaneously, which results in complex and high-cost ultrasound receiver systems. To address this issue, we have developed a new PA data acquisition approach using acoustic time delay. Optical fibers were used as parallel acoustic delay lines (PADLs) to create different time delays in multiple channels of PA signals. This makes the PA signals reach a single-element transducer at different times. As a result, they can be properly received by single-channel DAQ electronics. However, due to their small diameter and fragility, using optical fiber as acoustic delay lines poses a number of challenges in the design, construction and packaging of the PADLs, thereby limiting their performances and use in real imaging applications. In this paper, we report the development of new silicon PADLs, which are directly made from silicon wafers using advanced micromachining technologies. The silicon PADLs have very low acoustic attenuation and distortion. A linear array of 16 silicon PADLs were assembled into a handheld package with one common input port and one common output port. To demonstrate its real-time PAT capability, the silicon PADL array (with its output port interfaced with a single-element transducer) was used to receive 16 channels of PA signals simultaneously from a tissue-mimicking optical phantom sample. The reconstructed PA image matches well with the imaging target. Therefore, the silicon PADL array can provide a 16× reduction in the ultrasound DAQ channels for real-time PAT.
Liquid crystal polymer substrate MMIC receiver modules for the ECE Imaging system on the DIII-D
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Y.; Ye, Y.; Yu, J-H
A new generation of millimeter-wave heterodyne imaging receiver arrays has been developed and demonstrated on the DIII-D ECEI system. Improved circuit integration, allowing for absolute calibration, improved noise performance, and shielding from out-of-band emission, is made possible by using advanced liquid crystal polymer (LCP) substrates and MMIC (Monolithic Microwave Integrated Circuit) receiver chips. This array exhibits ~ 15 dB additional gain and > 30x reduction in noise temperature compared to the previous generation and provide ECEI capability for absolute 2-D electron temperature profile measurements. Each LCP horn-waveguide module houses a 3x3 mm GaAs MMIC receiver chip, which consists of amore » low noise amplifier (LNA), balanced mixer, local oscillator multiplier chain driven by ~12 GHz input via an RF cable to the enclosure box, and IF amplifier. A proof-of-principle instrument with 5 poloidal channels was installed on DIII-D in 2017. The full proof-of-principle system installation (20 poloidal x 8 radial channels) was commissioned early in 2018. The LCP ECEI system is used for pedestal region measurements, especially focusing on temperature evolution during ELM bursting. The DIII-D ECE Imaging signal has been significantly improved with extremely effective shielding of out-of-band microwave noise which plagued previous ECE Imaging studies on DIII-D. In H-mode ELM bursting, the radial propagation of electron heat flow has been detected on DIII-D. The LCP ECE Imaging is expected to be a valuable diagnostic tool for ELM physics investigations.« less
Integrated circuits for volumetric ultrasound imaging with 2-D CMUT arrays.
Bhuyan, Anshuman; Choe, Jung Woo; Lee, Byung Chul; Wygant, Ira O; Nikoozadeh, Amin; Oralkan, Ömer; Khuri-Yakub, Butrus T
2013-12-01
Real-time volumetric ultrasound imaging systems require transmit and receive circuitry to generate ultrasound beams and process received echo signals. The complexity of building such a system is high due to requirement of the front-end electronics needing to be very close to the transducer. A large number of elements also need to be interfaced to the back-end system and image processing of a large dataset could affect the imaging volume rate. In this work, we present a 3-D imaging system using capacitive micromachined ultrasonic transducer (CMUT) technology that addresses many of the challenges in building such a system. We demonstrate two approaches in integrating the transducer and the front-end electronics. The transducer is a 5-MHz CMUT array with an 8 mm × 8 mm aperture size. The aperture consists of 1024 elements (32 × 32) with an element pitch of 250 μm. An integrated circuit (IC) consists of a transmit beamformer and receive circuitry to improve the noise performance of the overall system. The assembly was interfaced with an FPGA and a back-end system (comprising of a data acquisition system and PC). The FPGA provided the digital I/O signals for the IC and the back-end system was used to process the received RF echo data (from the IC) and reconstruct the volume image using a phased array imaging approach. Imaging experiments were performed using wire and spring targets, a ventricle model and a human prostrate. Real-time volumetric images were captured at 5 volumes per second and are presented in this paper.
Paul, Christine L; Boyes, Allison W; O'Brien, Lorna; Baker, Amanda L; Henskens, Frans A; Roos, Ian; Clinton-McHarg, Tara; Bellamy, Douglas; Colburn, Glenda; Rose, Shiho; Cox, Martine E; Fradgley, Elizabeth A; Baird, Hannah; Barker, Daniel
2016-10-26
Community-based services such as telephone support lines can provide valuable informational, emotional, and practical support for cancer patients via telephone- or Web-based (live chat or email) platforms. However, very little rigorous research has examined the efficacy of such services in improving patient outcomes. This study will determine whether: proactive telephone or Web-delivered support produces outcomes superior to printed information; and Web-delivered support produces outcomes comparable to telephone support. A consecutive sample of 501 lung cancer outpatients will be recruited from 50 Australian health services to participate in a patient-randomized controlled trial (RCT). Eligible individuals must: be 18 years or older; have received a lung cancer diagnosis (including mesothelioma) within the previous 4 months; have an approximate life expectancy of at least 6 months; and have Internet access. Participants will be randomly allocated to receive: (1) an information booklet, (2) proactive telephone support, or (3) proactive Web support, chat, and/or email. The primary patient outcomes will be measured by the General Health Questionnaire (GHQ-12) and Health Education and Impact Questionnaire (heiQ) at 3 and 6 months post recruitment. The acceptability of proactive recruitment strategies will also be assessed. It is hypothesized that participants receiving telephone or Web support will report reduced distress (GHQ-12 scores that are 0.3 standard deviations (SD) lower) and greater self-efficacy (heiQ scores that are 0.3 SDs higher) than participants receiving booklets. Individuals receiving Web support will report heiQ scores within 0.29 SDs of individuals receiving telephone support. If proven effective, electronic approaches such as live-chat and email have the potential to increase the accessibility and continuity of supportive care delivered by community-based services. This evidence may also inform the redesigning of helpline-style services to be effective and responsive to patient needs.
Cohen, Genna R; Adler-Milstein, Julia
2016-04-01
Stage 2 and proposed Stage 3 meaningful use criteria ask providers to support patient care coordination by electronically generating, exchanging, and reconciling key information during patient care transitions. A stratified random sample of primary care practices in Michigan (n = 328) that had already met Stage 1 meaningful use criteria was surveyed, in order to identify the anticipated barriers to meeting these criteria as well as the expected impact on patient care coordination from doing so. The top three barriers, as identified by >65% of the primary care providers surveyed, were difficulty sending and receiving patient information electronically, a lack of provider and practice staff time, and the complex workflow changes required. Despite these barriers, primary care providers expressed strong agreement that meeting the proposed Stage 3 care coordination criteria would improve their patients' treatment and ensure they know about their patients' visits to other providers. The survey results suggest the need to enhance policy approaches and organizational strategies to address the key barriers identified by providers and practices in order to realize important care coordination benefits. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Bajwa, Mohammad
2014-01-01
With the implementation of Electronic Health Record (EHR), the patients’ health information will reside on the network of computers that can be accessed through a variety of techniques and technologies. One of the widely used present-day communication technology is the mobile/cell phone that has great potential in the healthcare delivery and management as the healthcare providers can remotely access electronically stored health information of patients from anywhere anytime. One of the greatest advantages of the mobile health technology is convenience of time-independent communication from geographically distant places with the healthcare centers and patients that enhances healthcare quality at reduced cost. However, its equally great disadvantage lies in sending and receiving the health information wirelessly through atmosphere which can be easily intercepted, eavesdropped, interjected, modified or even destroyed. PMID:25097542
Synaptic organic transistors with a vacuum-deposited charge-trapping nanosheet
NASA Astrophysics Data System (ADS)
Kim, Chang-Hyun; Sung, Sujin; Yoon, Myung-Han
2016-09-01
Organic neuromorphic devices hold great promise for unconventional signal processing and efficient human-machine interfaces. Herein, we propose novel synaptic organic transistors devised to overcome the traditional trade-off between channel conductance and memory performance. A vacuum-processed, nanoscale metallic interlayer provides an ultra-flat surface for a high-mobility molecular film as well as a desirable degree of charge trapping, allowing for low-temperature fabrication of uniform device arrays on plastic. The device architecture is implemented by widely available electronic materials in combination with conventional deposition methods. Therefore, our results are expected to generate broader interests in incorporation of organic electronics into large-area neuromorphic systems, with potential in gate-addressable complex logic circuits and transparent multifunctional interfaces receiving direct optical and cellular stimulation.
Bajwa, Mohammad
2014-07-01
With the implementation of Electronic Health Record (EHR), the patients' health information will reside on the network of computers that can be accessed through a variety of techniques and technologies. One of the widely used present-day communication technology is the mobile/cell phone that has great potential in the healthcare delivery and management as the healthcare providers can remotely access electronically stored health information of patients from anywhere anytime. One of the greatest advantages of the mobile health technology is convenience of time-independent communication from geographically distant places with the healthcare centers and patients that enhances healthcare quality at reduced cost. However, its equally great disadvantage lies in sending and receiving the health information wirelessly through atmosphere which can be easily intercepted, eavesdropped, interjected, modified or even destroyed.
Emission analysis of large number of various passenger electronic devices in aircraft
NASA Astrophysics Data System (ADS)
Schüür, Jens; Oppermann, Lukas; Enders, Achim; Nunes, Rafael R.; Oertel, Carl-Henrik
2016-09-01
The ever increasing use of PEDs (passenger or portable electronic devices) has put pressure on the aircraft industry as well as operators and administrations to reevaluate established restrictions in PED-use on airplanes in the last years. Any electronic device could cause electromagnetic interference to the electronics of the airplane, especially interference at receiving antennas of sensitive wireless navigation and communication (NAV/COM) systems. This paper presents a measurement campaign in an Airbus A320. 69 test passengers were asked to actively use a combination of about 150 electronic devices including many attached cables, preferentially with a high data load on their buses, to provoke maximal emissions. These emissions were analysed within the cabin as well as at the inputs of aircraft receiving antennas outside of the fuselage. The emissions of the electronic devices as well as the background noise are time-variant, so just comparing only one reference and one transmission measurement is not sufficient. Repeated measurements of both cases lead to a more reliable first analysis. Additional measurements of the absolute received power at the antennas of the airplane allow a good estimation of the real interference potential to aircraft NAV/COM systems. Although there were many measured emissions within the cabin, there were no disturbance signals detectable at the aircraft antennas.
Automated telephone reminder messages can assist electronic diabetes care.
Mollon, Brent; Holbrook, Anne M; Keshavjee, Karim; Troyan, Sue; Gaebel, Kathryn; Thabane, Lehana; Perera, Gihan
2008-01-01
Telephone reminder systems have been used to assist in the treatment of many chronic diseases. However, it is unclear if these systems can increase medication and appointment adherence in patients with diabetes without direct patient-provider telephone contact. We tested the feasibility of using an automated telephone reminder system (ATRS) to deliver reminder messages to 253 adults with diabetes enrolled in a randomized controlled trial. Eighty-four percent of the patients were able to register using voice recognition and at least one reminder was delivered to 95% of registered patients over a period of 7.5 months. None of the demographic features studied predicted a patient's ability to enroll or to receive reminder calls. At the end of the study, 63% of patients indicated that they wished to continue to receive ATRS calls. The level of system use as determined by the number of received reminder calls was not associated with a change in the number of physician visits or diabetes-related laboratory tests during follow-up. The clinical benefits and sustainability of ATRS remain unproven, but our results indicate that an automated reminder system can be effective for providing messages to a large group of older patients with diabetes.
Privacy enhanced group communication in clinical environment
NASA Astrophysics Data System (ADS)
Li, Mingyan; Narayanan, Sreeram; Poovendran, Radha
2005-04-01
Privacy protection of medical records has always been an important issue and is mandated by the recent Health Insurance Portability and Accountability Act (HIPAA) standards. In this paper, we propose security architectures for a tele-referring system that allows electronic group communication among professionals for better quality treatments, while protecting patient privacy against unauthorized access. Although DICOM defines the much-needed guidelines for confidentiality of medical data during transmission, there is no provision in the existing medical security systems to guarantee patient privacy once the data has been received. In our design, we address this issue by enabling tracing back to the recipient whose received data is disclosed to outsiders, using watermarking technique. We present security architecture design of a tele-referring system using a distributed approach and a centralized web-based approach. The resulting tele-referring system (i) provides confidentiality during the transmission and ensures integrity and authenticity of the received data, (ii) allows tracing of the recipient who has either distributed the data to outsiders or whose system has been compromised, (iii) provides proof of receipt or origin, and (iv) can be easy to use and low-cost to employ in clinical environment.
Estimating Total Electron Content Using 1,000+ GPS Receivers
NASA Technical Reports Server (NTRS)
Komjathy, Attila; Mannucci, Anthony
2006-01-01
A computer program uses data from more than 1,000 Global Positioning System (GPS) receivers in an Internet-accessible global network to generate daily estimates of the global distribution of vertical total electron content (VTEC) of the ionosphere. This program supersedes an older program capable of processing readings from only about 200 GPS receivers. This program downloads the data via the Internet, then processes the data in three stages. In the first stage, raw data from a global subnetwork of about 200 receivers are preprocessed, station by station, in a Kalman-filter-based least-squares estimation scheme that estimates satellite and receiver differential biases for these receivers and for satellites. In the second stage, an observation equation that incorporates the results from the first stage and the raw data from the remaining 800 receivers is solved to obtain the differential biases for these receivers. The only remaining error sources for which an account cannot be given are multipath and receiver noise contributions. The third stage is a postprocessing stage in which all the processed data are combined and used to generate new data products, including receiver differential biases and global and regional VTEC maps and animations.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-09
... INTERNATIONAL TRADE COMMISSION [DN 2882] Certain Consumer Electronics and Display Devices and... the U.S. International Trade Commission has received a complaint entitled Certain Consumer Electronics... importation of certain consumer electronics and display devices and products containing same. The complaint...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-28
... INTERNATIONAL TRADE COMMISSION [DN 2885] Certain Consumer Electronics, Including Mobile Phones and.... International Trade Commission has received a complaint entitled Certain Consumer Electronics, Including Mobile... electronics, including mobile phones and tablets. The complaint names as respondents ASUSTeK Computer, Inc. of...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-23
... INTERNATIONAL TRADE COMMISSION [DN 2858] Certain Consumer Electronics and Display Devices and.... International Trade Commission has received a complaint entitled In Re Certain Consumer Electronics and Display... importation of certain consumer electronics and display devices and products containing same. The complaint...
47 CFR 1.1113 - Filing locations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... by the ULS electronic filing system on FCC Form 159) and submit such number with the payment in order... received more than ten (10) days after electronic filing of an application on a Bureau/Office electronic... Television Relay Service (CARS) that are submitted electronically via the Cable Operations and Licensing...
48 CFR 252.232-7003 - Electronic submission of payment requests and receiving reports.
Code of Federal Regulations, 2012 CFR
2012-10-01
... not acceptable electronic forms for submission of payment requests. However, scanned documents are... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false Electronic submission of... PROVISIONS AND CONTRACT CLAUSES Text of Provisions And Clauses 252.232-7003 Electronic submission of payment...
48 CFR 252.232-7003 - Electronic submission of payment requests and receiving reports.
Code of Federal Regulations, 2011 CFR
2011-10-01
... not acceptable electronic forms for submission of payment requests. However, scanned documents are... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Electronic submission of... PROVISIONS AND CONTRACT CLAUSES Text of Provisions And Clauses 252.232-7003 Electronic submission of payment...
48 CFR 252.232-7003 - Electronic submission of payment requests and receiving reports.
Code of Federal Regulations, 2014 CFR
2014-10-01
... not acceptable electronic forms for submission of payment requests. However, scanned documents are... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false Electronic submission of... PROVISIONS AND CONTRACT CLAUSES Text of Provisions And Clauses 252.232-7003 Electronic submission of payment...
48 CFR 252.232-7003 - Electronic submission of payment requests and receiving reports.
Code of Federal Regulations, 2013 CFR
2013-10-01
... not acceptable electronic forms for submission of payment requests. However, scanned documents are... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Electronic submission of... PROVISIONS AND CONTRACT CLAUSES Text of Provisions And Clauses 252.232-7003 Electronic submission of payment...
48 CFR 252.232-7003 - Electronic submission of payment requests and receiving reports.
Code of Federal Regulations, 2010 CFR
2010-10-01
... not acceptable electronic forms for submission of payment requests. However, scanned documents are... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Electronic submission of... PROVISIONS AND CONTRACT CLAUSES Text of Provisions And Clauses 252.232-7003 Electronic submission of payment...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kar, Durga P.; Nayak, Praveen P.; Bhuyan, Satyanarayan
In order to power or charge electronic devices wirelessly, a bi-directional wireless power transfer method has been proposed and experimentally investigated. In the proposed design, two receiving coils are used on both sides of a transmitting coil along its central axis to receive the power wirelessly from the generated magnetic fields through strongly coupled magnetic resonance. It has been observed experimentally that the maximum power transfer occurs at the operating resonant frequency for optimum electric load connected across the receiving coils on both side. The optimum wireless power transfer efficiency is 88% for the bi-directional power transfer technique compared 84%more » in the one side receiver system. By adopting the developed bi-directional power transfer method, two electronic devices can be powered up or charged simultaneously instead of a single device through usual one side receiver system without affecting the optimum power transfer efficiency.« less
Medical devices utilizing optical fibers for simultaneous power, communications and control
Fitch, Joseph P.; Matthews, Dennis L.; Hagans, Karla G.; Lee, Abraham P.; Krulevitch, Peter; Benett, William J.; Clough, Robert E.; DaSilva, Luiz B.; Celliers, Peter M.
2003-06-10
A medical device is constructed in the basic form of a catheter having a distal end for insertion into and manipulation within a body and a proximal end providing for a user to control the manipulation of the distal end within the body. A fiberoptic cable is disposed within the catheter and having a distal end proximate to the distal end of the catheter and a proximal end for external coupling of laser light energy. A laser-light-to-mechanical-power converter is connected to receive light from the distal end of the fiber optic cable and may include a photo-voltaic cell and an electromechanical motor or a heat-sensitive photo-thermal material. An electronic sensor is connected to receive electrical power from said distal end of the fiberoptic cable and is connected to provide signal information about a particular physical environment and communicated externally through the fiberoptic cable to the proximal end thereof. A mechanical sensor is attached to the distal end of the fiberoptic cable and connected to provide light signal information about a particular physical environment and communicated externally through the fiberoptic cable.
Lepore, Stephen J; Winickoff, Jonathan P; Moughan, Beth; Bryant-Stephens, Tyra C; Taylor, Daniel R; Fleece, David; Davey, Adam; Nair, Uma S; Godfrey, Melissa; Collins, Bradley N
2013-08-30
Secondhand smoke exposure (SHSe) harms children's health, yet effective interventions to reduce child SHSe in the home and car have proven difficult to operationalize in pediatric practice. A multilevel intervention combining pediatric healthcare providers' advice with behavioral counseling and navigation to pharmacological cessation aids may improve SHSe control in pediatric populations. This trial uses a randomized, two-group design with three measurement periods: pre-intervention, end of treatment and 12-month follow-up. Smoking parents of children < 11-years-old are recruited from pediatric clinics. The clinic-level intervention includes integrating tobacco intervention guideline prompts into electronic health record screens. The prompts guide providers to ask all parents about child SHSe, advise about SHSe harms, and refer smokers to cessation resources. After receiving clinic intervention, eligible parents are randomized to receive: (a) a 3-month telephone-based behavioral counseling intervention designed to promote reduction in child SHSe, parent smoking cessation, and navigation to access nicotine replacement therapy or cessation medication or (b) an attention control nutrition education intervention. Healthcare providers and assessors are blind to group assignment. Cotinine is used to bioverify child SHSe (primary outcome) and parent quit status. This study tests an innovative multilevel approach to reducing child SHSe. The approach is sustainable, because clinics can easily integrate the tobacco intervention prompts related to "ask, advise, and refer" guidelines into electronic health records and refer smokers to free evidence-based behavioral counseling interventions, such as state quitlines. NCT01745393 (clinicaltrials.gov).
NASA Technical Reports Server (NTRS)
Hoang, S.; Meyer-Vernet, N.; Bougeret, J.-L.; Harvey, C. C.; Lacombe, C.; Mangeney, A.; Moncuquet, M.; Perche, C.; Steinberg, J.-L.; Macdowall, R. J.
1992-01-01
The radio receiver of the Unified Radio and Plasma experiment aboard the Ulysses spacecraft records spectra of the quasi-thermal plasma noise. The interpretation of these spectra allows the determination of the total electron density Ne and of the cold (core) electron temperature Tc in the solar wind. A single power law does not fit the variations of Ne which result from the contribution from different solar wind structures. The distribution of the values of Tc suggests that, on the average, the solar wind is nearly isothermal.
Personalised electronic messages to improve sun protection in young adults.
Mair, Sarah; Soyer, H Peter; Youl, Philippa; Hurst, Cameron; Marshall, Alison; Janda, Monika
2012-07-01
We studied the acceptability and feasibility of delivering sun protection messages via electronic media such as short message services (SMS) to people aged 18-40 years. An online survey was conducted using a pre-established panel of volunteers. We compared the characteristics of those who indicated that they would like to be alerted to the UV index, with those who would not, using bivariate logistic regression. Characteristics found to be associated with a desire to receive such advice were entered into a multivariate logistic regression analysis. The median age of the 141 participants was 34 years. Overall, 80% of participants agreed that they would like to receive some form of sun protection advice. Of these, 20% preferred to receive it via SMS and 42% via email. Willingness to receive electronic messages about the UV index was associated with being unsure about whether a suntanned person would look healthy and greater use of sun protection in the past. Careful attention to message framing and timing of message delivery, and focus on the short-term effects of sun exposure such as sunburn and skin ageing should increase the acceptability of such messages to young people. Sun protection messages delivered to young adults via electronic media appear to be feasible and acceptable.
NASA Astrophysics Data System (ADS)
Cushley, A. C.
2013-12-01
The proposed launch of a satellite carrying the first space-borne ADS-B receiver by the Royal Military College of Canada (RMCC) will create a unique opportunity to study the modification of the 1090 MHz radio waves following propagation through the ionosphere from the transmitting aircraft to the passive satellite receiver(s). Experimental work successfully demonstrated that ADS-B data can be used to reconstruct two dimensional (2D) electron density maps of the ionosphere using computerized tomography (CT). The goal of this work is to evaluate the feasibility of CT reconstruction. The data is modelled using Ray-tracing techniques. This allows us to determine the characteristics of individual waves, including the wave path and the state of polarization at the satellite receiver. The modelled Faraday rotation (FR) is determined and converted to total electron content (TEC) along the ray-paths. The resulting TEC is used as input for computerized ionospheric tomography (CIT) using algebraic reconstruction technique (ART). This study concentrated on meso-scale structures 100-1000 km in horizontal extent. The primary scientific interest of this thesis was to show the feasibility of a new method to image the ionosphere and obtain a better understanding of magneto-ionic wave propagation. Multiple feature input electron density profile to ray-tracing program. Top: reconstructed relative electron density map of ray-trace input (Fig. 1) using TEC measurements and line-of-sight path. Bottom: reconstructed electron density map of ray-trace input using quiet background a priori estimate.
Description of public health nursing nutrition assessment and interventions for home-visited women.
Horning, Melissa L; Olsen, Jeanette M; Lell, Shay; Thorson, Diane R; Monsen, Karen A
2018-05-09
The purpose of this manuscript was to describe: Public Health Nurse (PHN) home-visited, female client Nutrition Knowledge (K), Behavior (B), and Status (S); the number and types of nutrition interventions PHNs used with these clients; and the types of clients receiving nutrition interventions. This descriptive study used PHN-generated Omaha System, electronic health record data from January 2012 to July 2015. The analytic sample contains 558 women who received home visits in a rural Midwestern U.S. county that employed universal nutrition assessment for clients. Omaha System data included nutrition KBS scores (from 1 = low to 5 = high) and nutrition interventions delivered. Analyses included descriptive, bivariate, and multivariate analyses (means, frequencies, chi-squares, general linear models). PHNs assessed nutrition KBS scores for 84.1% of clients; average Nutrition Knowledge was 3.4 (SD = 0.7), Behavior 3.7 (SD = 0.8), and Status 4.3 (SD = 1.0). PHNs provided 0-36 nutrition interventions per client. Nutrition intervention patterns were detected by the type of visit clients received. Results suggest home-visited women have room to improve Nutrition KBS and PHNs utilize myriad nutrition interventions. Results also point to opportunities to improve home-visited client care by providing more nutrition interventions, especially to those not receiving interventions, and revising standard care plans to reflect important Case Management nutrition interventions. © 2018 Wiley Periodicals, Inc.
Robinson, June K.; Guevara, Yanina; Gaber, Rikki; Clayman, Marla L.; Kwasny, Mary J.; Friedewald, John J.; Gordon, Elisa J.
2014-01-01
A culturally sensitive educational intervention that encouraged sun protection behaviors among kidney transplant recipients was developed and the short-term efficacy was evaluated. Non-Hispanic White, Hispanic/Latino, and non-Hispanic Black patients, who received a transplant 2–24 months prior to the study, were randomized into two study groups: intervention versus standard of care. Electronic reminders tailored to the weather conditions were sent every two weeks by text message or email. Self-reported surveys and biologic measurements were obtained prior to the intervention and six weeks later. Among the 101 study participants, there was a statistically significant increase in knowledge, recognition of personal risk of developing skin cancer, willingness to change sun protection behavior, and self-reported performance of sun protection in participants receiving the intervention in comparison with those receiving standard of care (p <0.05). The pigment darkening of the sun–exposed forearm and sun damage of the forearm and sunburns/ skin irritation from the sun were significantly less in participants receiving the intervention (p <0.05). Providing sun protection education at the beginning of summer with reminders tailored to weather conditions helped KTRs adopt sun protection practices. This sun protection program for KTRs may be incorporated into the care provided by the nephrologist or transplant surgeon. PMID:25395386
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-20
...DoD is issuing a final rule amending the Defense Federal Acquisition Regulation Supplement (DFARS), Appendix F, Material Inspection and Receiving Report, to incorporate new procedures for using the electronic Wide Area WorkFlow (WAWF) Receiving Report.
21 CFR 1020.10 - Television receivers.
Code of Federal Regulations, 2012 CFR
2012-04-01
..., under normal usage, are not accessible to the user. (4) Television receiver means an electronic product designed to receive and display a television picture through broadcast, cable, or closed circuit television... from that component or circuit failure which maximizes x-radiation emissions. (4) Critical component...
21 CFR 1020.10 - Television receivers.
Code of Federal Regulations, 2013 CFR
2013-04-01
..., under normal usage, are not accessible to the user. (4) Television receiver means an electronic product designed to receive and display a television picture through broadcast, cable, or closed circuit television... from that component or circuit failure which maximizes x-radiation emissions. (4) Critical component...
21 CFR 1020.10 - Television receivers.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., under normal usage, are not accessible to the user. (4) Television receiver means an electronic product designed to receive and display a television picture through broadcast, cable, or closed circuit television... from that component or circuit failure which maximizes x-radiation emissions. (4) Critical component...
21 CFR 1020.10 - Television receivers.
Code of Federal Regulations, 2011 CFR
2011-04-01
..., under normal usage, are not accessible to the user. (4) Television receiver means an electronic product designed to receive and display a television picture through broadcast, cable, or closed circuit television... from that component or circuit failure which maximizes x-radiation emissions. (4) Critical component...
21 CFR 1020.10 - Television receivers.
Code of Federal Regulations, 2014 CFR
2014-04-01
..., under normal usage, are not accessible to the user. (4) Television receiver means an electronic product designed to receive and display a television picture through broadcast, cable, or closed circuit television... from that component or circuit failure which maximizes x-radiation emissions. (4) Critical component...
NASA Astrophysics Data System (ADS)
Sarlanis, Christos; Heber, Bernd; Labrenz, Johannes; Kühl, Patrick; Marquardt, Johannes; Dimitroulakos, John; Papaioannou, Athanasios; Posner, Arik
2017-04-01
Solar Energetic Particle (SEP) events are one of the most important elements of space weather. Given that the complexity of the underlying physical processes of the acceleration and propagation of SEP events is still a very active research area, the prognosis of SEP event occurrence and their corresponding characteristics remains challenging. In order to provide up to an hour warning time before these particles arrive at Earth, relativistic electron and below 50 MeV proton data from the Electron Proton Helium Instrument (EPHIN) on SOHO were used to implement the 'Relativistic Electron Alert System for Exploration (REleASE)'. The REleASE forecasting scheme was recently rewritten in the open access programming language PYTHON and will be made publicly available. As a next step, along with relativistic electrons (v > 0.9 c) provided by SOHO, near-relativistic (v <0.8 c) electron measurements from other instruments like the Electron Proton Alpha Monitor (EPAM) aboard the Advanced Composition Explorer (ACE) have been utilized. In this work, we demonstrate the real-time outputs derived by the end user from the REleASE using both SOHO/EPHIN and ACE/EPAM. We further, show a user friendly illustration of the outputs that make use of a "traffic light" to monitor the different warning stages: quiet, warning, alert offering a simple guidance to the end users. Finally, the capabilities offered by this new system, accessing both the pictorial and textural outputs REleASE are being presented. This work has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement No 637324.
The Relationship between Ionospheric Slab Thickness and the Peak Density Height, hmF2
NASA Astrophysics Data System (ADS)
Meehan, J.; Sojka, J. J.
2017-12-01
The electron density profile is one of the most critical elements in the ionospheric modeling-related applications today. Ionosphere parameters, hmF2, the height of the peak density layer, and slab thickness, the ratio of the total electron content, TEC, to the peak density value, NmF2, are generally obtained from any global sounding observation network and are easily incorporated into models, theoretical or empirical, as numerical representations. Slab thickness is a convenient one-parameter summary of the electron density profile and can relate a variety of elements of interest that effect the overall electron profile shape, such as the neutral and ionospheric temperatures and gradients, the ionospheric composition, and dynamics. Using ISR data from the 2002 Millstone Hill ISR data campaign, we found, for the first time, slab thickness to be correlated to hmF2. For this, we introduce a new ionospheric index, k, which ultimately relates electron density parameters and can be a very useful tool for describing the topside ionosphere shape. Our study is an initial one location, one season, 30-day study, and future work is needed to verify the robustness of our claim. Generally, the ionospheric profile shape, requires knowledge of several ionospheric parameters: electron, ion and neutral temperatures, ion composition, electric fields, and neutral winds, and is dependent upon seasons, local time, location, and the level of solar and geomagnetic activity; however, with this new index, only readily-available, ionospheric density information is needed. Such information, as used in this study, is obtained from a bottomside electron density profile provided by an ionosonde, and TEC data provided by a local, collocated GPS receiver.
Wireless monitoring of highways
NASA Astrophysics Data System (ADS)
Bennett, Richard; Hayes-Gill, Barrie; Crowe, John A.; Armitage, Robert; Rodgers, Dale; Hendroff, Adrian
1999-05-01
Electronic hardware has been developed to telemetrically transmit temperature and strain measurements from within a public highway in the UK. These measurements provide an important health check for monitoring fatigue damage in pavements. Previous attempts at measuring strain and temperature have required lengths of cable to be installed in the highway. The installation of these cables is both expensive and damaging to the pavement and provides potentially unreliable electrical connections. The new systems consist of a retrofitted instrumented asphalt core which is bonded into the pavement structure. The core contains all the electronics necessary to record two temperatures and two strains. An analogue front end provides signal conditioning which is digitized and passed to microcontroller for endcoding. From there the data is transmitted via a low power radio link to a receiver and data logger positioned by the side of the road. The system has an in-situ operating life of 6 months on AA alkaline batteries. Results are presented of power management and fault tolerant radio protocol techniques, long term temperature variations, dynamic strain measurements within the highway, and RF transmission capabilities through a layer of asphalt.
5 CFR 1201.4 - General definitions.
Code of Federal Regulations, 2011 CFR
2011-01-01
... documents associated with electronic filings under paragraph (h) of § 1201.14, on the MSPB. (l) Date of... date of electronic submission. (m) Electronic filing (e-filing). Filing and receiving documents in... of Personnel Management reconsideration decisions concerning retirement benefits, and appeals of...
5 CFR 1201.4 - General definitions.
Code of Federal Regulations, 2012 CFR
2012-01-01
... documents associated with electronic filings under paragraph (h) of § 1201.14, on the MSPB. (l) Date of... date of electronic submission. (m) Electronic filing (e-filing). Filing and receiving documents in... of Personnel Management reconsideration decisions concerning retirement benefits, and appeals of...
NASA Astrophysics Data System (ADS)
Poli, E.; Bock, A.; Lochbrunner, M.; Maj, O.; Reich, M.; Snicker, A.; Stegmeir, A.; Volpe, F.; Bertelli, N.; Bilato, R.; Conway, G. D.; Farina, D.; Felici, F.; Figini, L.; Fischer, R.; Galperti, C.; Happel, T.; Lin-Liu, Y. R.; Marushchenko, N. B.; Mszanowski, U.; Poli, F. M.; Stober, J.; Westerhof, E.; Zille, R.; Peeters, A. G.; Pereverzev, G. V.
2018-04-01
The paraxial WKB code TORBEAM (Poli, 2001) is widely used for the description of electron-cyclotron waves in fusion plasmas, retaining diffraction effects through the solution of a set of ordinary differential equations. With respect to its original form, the code has undergone significant transformations and extensions, in terms of both the physical model and the spectrum of applications. The code has been rewritten in Fortran 90 and transformed into a library, which can be called from within different (not necessarily Fortran-based) workflows. The models for both absorption and current drive have been extended, including e.g. fully-relativistic calculation of the absorption coefficient, momentum conservation in electron-electron collisions and the contribution of more than one harmonic to current drive. The code can be run also for reflectometry applications, with relativistic corrections for the electron mass. Formulas that provide the coupling between the reflected beam and the receiver have been developed. Accelerated versions of the code are available, with the reduced physics goal of inferring the location of maximum absorption (including or not the total driven current) for a given setting of the launcher mirrors. Optionally, plasma volumes within given flux surfaces and corresponding values of minimum and maximum magnetic field can be provided externally to speed up the calculation of full driven-current profiles. These can be employed in real-time control algorithms or for fast data analysis.
Dutch virtual integration of healthcare information.
de Graaf, J C; Vlug, A E; van Boven, G J
2007-01-01
As information technology creates opportunities for cooperation which crosses the boundaries between healthcare institutions, it will become an integral part of the Dutch healthcare system. Along with many involved organizations in healthcare the National IT Institute for Healthcare in the Netherlands (NICTIZ) is working on the realization of a national IT infrastructure for healthcare and a national electronic patient record (EPR). An underlying national architecture is designed to enable the Dutch EPR virtually, not in a national database, nor on a patient's smartcard. The required secure infrastructure provides generic functions for healthcare applications: patient identification, authentication and authorization of healthcare professionals. The first national applications in the EPR program using a national index of where patient data is stored, are the electronic medication record and the electronic record for after hours GP services. The rollout of the electronic medication record and electronic record for after hours GP services has been started in 2007. To guarantee progress of electronic data exchange in healthcare in the Netherlands we have primarily opted for two healthcare applications: the electronic medication record and the electronic record for after hours GP services. The use of a national switch-point containing the registry of where to find what information, guarantees that the professional receives the most recent information and omits large databases to contain downloaded data. Proper authorization, authentication as well as tracing by the national switchpoint also ensures a secure environment for the communication of delicate information.
Apparatus for downhole drilling communications and method for making and using the same
Normann, Randy A.; Lockwood, Grant J.; Gonzales, Meliton
1998-01-01
An apparatus for downhole drilling communications is presented. The apparatus includes a spool and end pieces for maintaining the spool at the bottom of a drill string near a drill bit during drilling operations. The apparatus provides a cable for communicating signals between a downhole electronics package and a surface receiver in order to perform measurements while drilling. A method of forming the apparatus is also set forth wherein the apparatus is formed about a central spindle and lathe.
Apparatus for downhole drilling communications and method for making and using the same
Normann, R.A.; Lockwood, G.J.; Gonzales, M.
1998-03-03
An apparatus for downhole drilling communications is presented. The apparatus includes a spool and end pieces for maintaining the spool at the bottom of a drill string near a drill bit during drilling operations. The apparatus provides a cable for communicating signals between a downhole electronics package and a surface receiver in order to perform measurements while drilling. A method of forming the apparatus is also set forth wherein the apparatus is formed about a central spindle and lathe. 6 figs.
High-performance parallel interface to synchronous optical network gateway
St. John, Wallace B.; DuBois, David H.
1998-08-11
A digital system provides sending and receiving gateways for HIPPI interfaces. Electronic logic circuitry formats data signals and overhead signals in a data frame that is suitable for transmission over a connecting fiber optic link. Multiplexers route the data and overhead signals to a framer module. The framer module allocates the data and overhead signals to a plurality of 9-byte words that are arranged in a selected protocol. The formatted words are stored in a storage register for output through the gateway.
Global Combat Support Basing. Robust Prepositioning Strategies for Air Force War Reserve Material
2010-01-01
e.g., WRM assets at b may receive their mainte- nance from a traveling maintenance team based offsite at b’ ). Both the 5 Mark S. Daskin , Lawrence V...This document and trademark(s) contained herein are protected by law as indicated in a notice appearing later in this work. This electronic...representation of RAND intellectual property is provided for non-commercial use only. Unauthorized posting of RAND PDFs to a non-RAND Web site is
Mixed species radioiodine air sampling readout and dose assessment system
Distenfeld, Carl H.; Klemish, Jr., Joseph R.
1978-01-01
This invention provides a simple, reliable, inexpensive and portable means and method for determining the thyroid dose rate of mixed airborne species of solid and gaseous radioiodine without requiring highly skilled personnel, such as health physicists or electronics technicians. To this end, this invention provides a means and method for sampling a gas from a source of a mixed species of solid and gaseous radioiodine for collection of the mixed species and readout and assessment of the emissions therefrom by cylindrically, concentrically and annularly molding the respective species around a cylindrical passage for receiving a conventional probe-type Geiger-Mueller radiation detector.
Contraceptive Provision to Adolescent Females Prescribed Teratogenic Medications.
Stancil, Stephani L; Miller, Melissa; Briggs, Holley; Lynch, Daryl; Goggin, Kathy; Kearns, Gregory
2016-01-01
Rates of adult women receiving contraceptive provision when simultaneously prescribed a known teratogen are alarmingly low. The prevalence of this behavior among pediatric providers and their adolescent patients is unknown. The objective of this study was to describe pediatric provider behaviors for prescribing teratogens concurrently with counseling, referral, and/or prescribing of contraception (collectively called contraceptive provision) in the adolescent population. A retrospective review was conducted examining visits in 2008-2012 by adolescents aged 14 to 25 years in which a known teratogen (US Food and Drug Administration pregnancy risk category D or X) was prescribed. The electronic medical records were queried for demographic information, evidence of contraceptive provision, and menstrual and sexual histories. The data were analyzed using standard statistical methods. Within 4172 clinic visits, 1694 females received 4506 prescriptions for teratogenic medications. The most commonly prescribed teratogens were topiramate, methotrexate, diazepam, isotretinoin, and enalapril. The subspecialties prescribing teratogens most frequently were neurology, hematology-oncology, and dermatology. Overall, contraceptive provision was documented in 28.6% of the visits. Whites versus nonwhites and older versus younger girls were more likely to receive contraceptive provision. The presence of a federal risk mitigation system for the teratogen also increased the likelihood of contraceptive provision. Our data demonstrate female adolescents prescribed teratogens receive inadequate contraception provision, which could increase their risk for negative pregnancy outcomes. Although the presence of a federal risk mitigation system appears to improve contraceptive provision, these systems are costly and, in some instances, difficult to implement. Efforts to improve provider practices are needed. Copyright © 2016 by the American Academy of Pediatrics.
Field-portable supercritical CO{sub 2} extractor
Wright, B.W.; Zemanian, T.S.; Robins, W.H.; Woodcock, L.J.
1997-06-10
The present invention is an apparatus for extracting organic compounds from solid materials. A generator vessel has a removable closure for receiving a solid or liquid solvent which is heated with a resistive heating element to a gaseous or supercritical phase. The removable closure is unencumbered because the side wall is penetrated with an outlet for the gaseous or supercritical solvent. The generator vessel further has a pressure transducer that provides an electronic signal related to pressure of the gaseous or supercritical solvent. The apparatus of the present invention further includes at least one extraction cell having a top and a bottom and a wall extending there between, wherein the bottom is sealably penetrated by an inlet for gaseous or supercritical solvent received through a manifold connected to the outlet, the top having an easy-open removable closure cap, and the wall having an outlet port. Finally, a permeable sample cartridge is included for holding the solid materials and to provide radial-flow of the extraction fluid, which is placed within the extraction cell. 10 figs.
Field-portable supercritical CO.sub.2 extractor
Wright, Bob W.; Zemanian, Thomas S.; Robins, William H.; Woodcock, Leslie J.
1997-01-01
The present invention is an apparatus for extracting organic compounds from solid materials. A generator vessel has a removable closure for receiving a solid or liquid solvent which is heated with a resistive heating element to a gaseous or supercritical phase. The removable closure is unencumbered because the side wall is penetrated with an outlet for the gaseous or supercritical solvent. The generator vessel further has a pressure transducer that provides an electronic signal related to pressure of the gaseous or supercritical solvent. The apparatus of the present invention further includes at least one extraction cell having a top and a bottom and a wall extending therebetween, wherein the bottom is sealably penetrated by an inlet for gaseous or supercritical solvent received through a manifold connected to the outlet, the top having an easy-open removable closure cap, and the wall having an outlet port. Finally, a permeable sample cartridge is included for holding the solid materials and to provide radial-flow of the extraction fluid, which is placed within the extraction cell.
Influenza and pneumococcal vaccinations in dialysis patients in a London district general hospital.
Wilmore, Stephanie M S; Philip, Keir E; Cambiano, Valentina; Bretherton, Christopher P; Harborne, Josephine E; Sharma, Aditi; Jayasena, Shyama D
2014-02-01
Patients on dialysis mount reduced immune responses compared with the general population. The Department of Health advises that these patients receive influenza and pneumococcal vaccinations at regular intervals-once yearly and every five years, respectively. This article investigates the uptake of these vaccinations in this patient population and seeks to examine factors that may influence vaccination status such as patient's language and presence of a general practitioner (GP) electronic vaccination reminder system. It also explores preferred site of vaccination for patients and GPs as these are primary care vaccinations yet patients have more frequent contact with their dialysis unit than their GP, blurring the boundaries between primary and specialized care. This is a retrospective study of all patients registered as dialysing at the North Middlesex University Hospital NHS Trust (NMUH) in September 2011. Information was obtained through GP letters, GP and patient questionnaires. Of 154 patients, 133 were included in the data analysis. Nineteen per cent were up-to-date with both vaccinations and 67% with their influenza vaccination. Fifty per cent had received the influenza vaccination in the last two consecutive years. Thirty per cent were not up-to-date with either vaccination. There was no evidence of a difference in uptake in 2009 (P = 0.7564) and in 2010 (P = 0.7435) among those who could and could not speak English. Twenty-five per cent of GPs and 58.6% of patients preferred vaccination to occur in the dialysis unit. Unfortunately a high number of GPs did not provide information on whether they used an electronic vaccination reminder but the analysis from the information provided by the few respondents did not reveal any correlation between the presence of an electronic reminder and vaccination status. Most dialysis patients were not up-to-date with both vaccinations. They were, however, more up-to-date with their influenza than their pneumococcal vaccination. Non-English speakers did not appear to be disadvantaged. GP electronic reminder systems may have influenced influenza uptake but this study did not demonstrate a correlation and this is likely due to the lack of GP respondents; the effectiveness of electronic reminders merits further studies as a tool to improve vaccination rates in at-risk populations. Most patients visited their GP at least annually but preferred to receive their vaccinations at the hospital. Vaccinating in the dialysis unit and maintaining an electronic record accessible to GPs or generating a letter for GPs may help fill the vaccination gap in these patients. Overall, more evidence is required for the effectiveness of such vaccinations and their frequency, but in the meantime UK national guidelines were not being followed with a large proportion of patients remaining unvaccinated against influenza and in particular pneumococcal disease. This audit highlights the importance of local data collection, discussions around correlations influencing outcomes and publication of results to improve standards of care at a national level.
Influenza and pneumococcal vaccinations in dialysis patients in a London district general hospital
Wilmore, Stephanie M.S.; Philip, Keir E.; Cambiano, Valentina; Bretherton, Christopher P.; Harborne, Josephine E.; Sharma, Aditi; Jayasena, Shyama D.
2014-01-01
Background Patients on dialysis mount reduced immune responses compared with the general population. The Department of Health advises that these patients receive influenza and pneumococcal vaccinations at regular intervals—once yearly and every five years, respectively. This article investigates the uptake of these vaccinations in this patient population and seeks to examine factors that may influence vaccination status such as patient's language and presence of a general practitioner (GP) electronic vaccination reminder system. It also explores preferred site of vaccination for patients and GPs as these are primary care vaccinations yet patients have more frequent contact with their dialysis unit than their GP, blurring the boundaries between primary and specialized care. Methods This is a retrospective study of all patients registered as dialysing at the North Middlesex University Hospital NHS Trust (NMUH) in September 2011. Information was obtained through GP letters, GP and patient questionnaires. Results Of 154 patients, 133 were included in the data analysis. Nineteen per cent were up-to-date with both vaccinations and 67% with their influenza vaccination. Fifty per cent had received the influenza vaccination in the last two consecutive years. Thirty per cent were not up-to-date with either vaccination. There was no evidence of a difference in uptake in 2009 (P = 0.7564) and in 2010 (P = 0.7435) among those who could and could not speak English. Twenty-five per cent of GPs and 58.6% of patients preferred vaccination to occur in the dialysis unit. Unfortunately a high number of GPs did not provide information on whether they used an electronic vaccination reminder but the analysis from the information provided by the few respondents did not reveal any correlation between the presence of an electronic reminder and vaccination status. Conclusion Most dialysis patients were not up-to-date with both vaccinations. They were, however, more up-to-date with their influenza than their pneumococcal vaccination. Non-English speakers did not appear to be disadvantaged. GP electronic reminder systems may have influenced influenza uptake but this study did not demonstrate a correlation and this is likely due to the lack of GP respondents; the effectiveness of electronic reminders merits further studies as a tool to improve vaccination rates in at-risk populations. Most patients visited their GP at least annually but preferred to receive their vaccinations at the hospital. Vaccinating in the dialysis unit and maintaining an electronic record accessible to GPs or generating a letter for GPs may help fill the vaccination gap in these patients. Overall, more evidence is required for the effectiveness of such vaccinations and their frequency, but in the meantime UK national guidelines were not being followed with a large proportion of patients remaining unvaccinated against influenza and in particular pneumococcal disease. This audit highlights the importance of local data collection, discussions around correlations influencing outcomes and publication of results to improve standards of care at a national level. PMID:24466425
NASA Astrophysics Data System (ADS)
Kunitsyn, V.; Nesterov, I.; Andreeva, E.; Rekenthaler, D. A.
2012-12-01
Ionospheric radio-tomography (RT) utilizes radio signals transmitted from the global navigational satellite systems (GNSS), including low-orbiting (LO) navigational systems such as Transit, Tsikada, etc., and high-orbiting (HO) navigational systems such as GPS, GLONASS, Galileo, Beidou, etc. The signals that are transmitted from the LO navigational satellites and recorded by ground receiving chains can be inverted for almost instantaneous (5-8 min) 2D snapshots of electron density. The data from the networks of ground receivers that record the signals of the HO satellites are suitable for implementing high-orbital RT (HORT), i.e. reconstructing the 4D distributions of the ionospheric electron density (one 3D image every 20-30 min). In the regions densely covered by the GNSS receivers, it is currently possible to get a time step of 2-4 min. The LORT and HORT approaches have a common methodical basis: in both these techniques, the integrals of electron density along the ray between the satellite and the receiver are measured, and then the tomographic procedures are applied to reconstruct the distributions of electron density. We present several examples of the experiments on the ionospheric RT, which are related to the Underground-Surface-Atmosphere-Ionosphere (USAI) coupling. In particular, we demonstrate examples of RT images of the ionosphere after industrial explosions, rocket launches, and modification of the ionosphere by high-power radio waves. We also show RT cross sections reflecting ionospheric disturbances caused by the earthquakes (EQ) and tsunami waves. In these cases, there is an evident cause-and-effect relationship. The perturbations are transferred between the geospheres predominantly by acoustic gravity waves (AGW), whose amplitudes increase with increasing height. As far as EQ are concerned, the cause of the USAI coupling mechanism is not obvious. It is clear, however, that the regular RT studies can promote the solution of this challenging problem. The single-point measurements (by ionosondes or by isolated receivers) are not amenable to unambiguous interpretation; based on these data, it is impossible to distinguish the contribution of USAI coupling from the ionospheric effects induced by the "ordinary" impacts (the Sun, the solar wind, geomagnetic perturbations, galactic cosmic rays, etc.). In order to localize sources of the ionospheric disturbances, the geophysicist needs information on the spatial structure and dynamics of the ionospheric perturbations. This information (2D-4D RT images) is optimally provided by RT methods. We present examples of the ionospheric disturbances caused by EQs as well as the ionospheric precursors of these EQs in the form of specific ionospheric irregularities: AGW- and soliton-like wave disturbances, which we identified using RT methods. Based on the results of the RT studies in the Alaska and Taiwan regions, we have detected several dozen AGW-related precursors of EQs. These data allow us to attempt to locate the source of these perturbations. We discuss the possibilities and prospects of further research aimed at identifying and analyzing precursors of EQs and establishing the mechanisms of USAI coupling. We are grateful to Northwest Research Associates, Inc., and Dr. L.-C.Tsai for providing raw RT data for Alaska and Taiwan.
Freundlich, Robert E; Barnet, Caryn S; Mathis, Michael R; Shanks, Amy M; Tremper, Kevin K; Kheterpal, Sachin
2013-03-01
To investigate whether alerting providers to errors results in improved documentation of reimbursable anesthesia care. Prospective randomized controlled trial. Operating room (OR) of a university hospital. Anesthesia cases were evaluated to determine whether they met the definition for appropriate anesthesia start time over 4 separate, 45-day calendar cycles: the pre-study period, study period, immediate post-study period, and 3-year follow-up period. During the study period, providers were randomly assigned to either a control or an alert group. Providers in the alert cohort received an automated alphanumeric page if the anesthesia start time occurred concurrently with the patient entering the OR, or more than 30 minutes before entering the OR. Three years after the intervention period, overall compliance was analyzed to assess learned behavior. Baseline compliance was 33% ± 5%. During the intervention period, providers in the alert group showed 87% ± 6% compliance compared with 41% ± 7% compliance in the control group (P < 0.001). Long-term follow-up after cessation of the alerts showed 85% ± 4% compliance. Automated electronic reminders for time-based billing charges are effective and result in improved ongoing reimbursement. Copyright © 2013 Elsevier Inc. All rights reserved.
Klein, Doug; Staples, John; Pittman, Carmen; Stepanko, Cheryl
2012-01-01
The traditional needs assessment used in developing continuing medical education programs typically relies on surveying physicians and tends to only capture perceived learning needs. Instead, using tools available in electronic medical record systems to perform a clinical audit on a physician's practice highlights physician-specific practice patterns. The purpose of this study was to test the feasibility of implementing an electronic clinical audit needs assessment process for family physicians in Canada. A clinical audit of 10 preventative care interventions and 10 chronic disease interventions was performed on family physician practices in Alberta, Canada. The physicians used the results from the audit to produce personalized learning needs, which were then translated into educational programming. A total of 26 family practices and 4489 patient records were audited. Documented completion rates for interventions ranged from 13% for ensuring a patient's tetanus vaccine is current to 97% of pregnant patients receiving the recommended prenatal vitamins. Electronic medical record-based needs assessments may provide a better basis for developing continuing medical education than a more traditional survey-based needs assessment. This electronic needs assessment uses the physician's own patient outcome information to assist in determining learning objectives that reflect both perceived and unperceived needs.
49 CFR 172.204 - Shipper's certification.
Code of Federal Regulations, 2012 CFR
2012-10-01
... may be received verbally or with an electronic signature in conformance with paragraphs (a)(3)(i) and...) Electronic Signature Certification. When transmitted electronically, by completing the field designated for... agent must be substituted for the asterisks; (b) Exceptions. (1) Except for a hazardous waste, no...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-15
... INTERNATIONAL TRADE COMMISSION [DN 2875] Certain Mobile Electronic Devices Incorporating Haptics.... International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that the U.S. International Trade Commission has received an amended complaint entitled Certain Mobile Electronic Devices...
5 CFR 1201.4 - General definitions.
Code of Federal Regulations, 2014 CFR
2014-01-01
... electronic submission. (m) Electronic filing (e-filing). Filing and receiving documents in electronic form in... took the action. Appeals of Office of Personnel Management reconsideration decisions concerning... proceeding. This term applies to the Office of Personnel Management and to the Office of Special Counsel when...
NASA Astrophysics Data System (ADS)
Lynam, Jeff R.
2001-09-01
A more highly integrated, electro-optical sensor suite using Laser Illuminated Viewing and Ranging (LIVAR) techniques is being developed under the Army Advanced Concept Technology- II (ACT-II) program for enhanced manportable target surveillance and identification. The ManPortable LIVAR system currently in development employs a wide-array of sensor technologies that provides the foot-bound soldier and UGV significant advantages and capabilities in lightweight, fieldable, target location, ranging and imaging systems. The unit incorporates a wide field-of-view, 5DEG x 3DEG, uncooled LWIR passive sensor for primary target location. Laser range finding and active illumination is done with a triggered, flash-lamp pumped, eyesafe micro-laser operating in the 1.5 micron region, and is used in conjunction with a range-gated, electron-bombarded CCD digital camera to then image the target objective in a more- narrow, 0.3$DEG, field-of-view. Target range determination is acquired using the integrated LRF and a target position is calculated using data from other onboard devices providing GPS coordinates, tilt, bank and corrected magnetic azimuth. Range gate timing and coordinated receiver optics focus control allow for target imaging operations to be optimized. The onboard control electronics provide power efficient, system operations for extended field use periods from the internal, rechargeable battery packs. Image data storage, transmission, and processing performance capabilities are also being incorporated to provide the best all-around support, for the electronic battlefield, in this type of system. The paper will describe flash laser illumination technology, EBCCD camera technology with flash laser detection system, and image resolution improvement through frame averaging.
Azam, Mohd Asyadi; Alias, Farizul Muiz; Tack, Liew Weng; Seman, Raja Noor Amalina Raja; Taib, Mohamad Fariz Mohamad
2017-08-01
Carbon nanotubes (CNTs) have received enormous attention due to their fascinating properties to be used in various applications including electronics, sensing, energy storage and conversion. The first principles calculations within density functional theory (DFT) have been carried out in order to investigate the structural, electronic and optical properties of un-doped and doped CNT nanostructures. O 2 , CO 2 , and CH 3 OH have been chosen as gas molecules to study the adsorption properties based on zigzag (8,0) SWCNTs. The results demonstrate that the adsorption of O 2 , CO 2, and CH 3 OH gas molecules on pristine, Si-doped and B-doped SWCNTs are either physisorption or chemisorption. Moreover, the electronic properties indicating SWCNT shows significant improvement toward gas adsorption which provides the impact of selecting the best gas sensor materials towards detecting gas molecule. Therefore, these pristine, Si-, and B-doped SWCNTs can be considered to be very good potential candidates for sensing application. Copyright © 2017 Elsevier Inc. All rights reserved.
Evaluating Common Privacy Vulnerabilities in Internet Service Providers
NASA Astrophysics Data System (ADS)
Kotzanikolaou, Panayiotis; Maniatis, Sotirios; Nikolouzou, Eugenia; Stathopoulos, Vassilios
Privacy in electronic communications receives increased attention in both research and industry forums, stemming from both the users' needs and from legal and regulatory requirements in national or international context. Privacy in internet-based communications heavily relies on the level of security of the Internet Service Providers (ISPs), as well as on the security awareness of the end users. This paper discusses the role of the ISP in the privacy of the communications. Based on real security audits performed in national-wide ISPs, we illustrate privacy-specific threats and vulnerabilities that many providers fail to address when implementing their security policies. We subsequently provide and discuss specific security measures that the ISPs can implement, in order to fine-tune their security policies in the context of privacy protection.
Command and Service Module Communications
NASA Technical Reports Server (NTRS)
Interbartolo, Michael
2009-01-01
This viewgraph presentation examines Command and Service Module (CSM) Communications. The communication system's capabilities are defined, including CSM-Earth, CSM-Lunar Module and CSM-Extravehicular crewman communications. An overview is provided for S-band communications, including data transmission and receiving rates, operating frequencies and major system components (pre-modulation processors, unified S-band electronics, S-band power amplifier and S-band antennas). Additionally, data transmission rates, operating frequencies and the capabilities of VHF communications are described. Major VHF components, including transmitters and receivers, and the VHF multiplexer and antennas are also highlighted. Finally, communications during pre-launch, ascent, in-flight and entry are discussed. Overall, the CSM communication system was rated highly by flight controllers and crew. The system was mostly autonomous for both crew and flight controllers and no major issues were encountered during flight.
Facilitating the Feedback Process on a Clinical Clerkship Using a Smartphone Application.
Joshi, Aditya; Generalla, Jenilee; Thompson, Britta; Haidet, Paul
2017-10-01
This pilot study evaluated the effects of a smartphone-triggered method of feedback delivery on students' perceptions of the feedback process. An interactive electronic feedback form was made available to students through a smartphone app. Students were asked to evaluate various aspects of the feedback process. Responses from a previous year served as control. In the first three quarters of academic year 2014-2015 (pre-implementation), only 65% of responders reported receiving oral feedback and 40% reported receiving written feedback. During the pilot phase (transition), these increased to 80% for both forms. Following full implementation in academic year 2015-2016 (post-implementation), 97% reported receiving oral feedback, and 92% reported receiving written feedback. A statistically significant difference was noted pre- to post-implementation for both oral and written feedback (p < 0.01). A significant increase from pre-implementation to transition was noted for written feedback (p < 0.01) and from transition to post-implementation for oral feedback (p < 0.01). Ninety-one and 94% of responders reported ease of access and timeliness of the feedback, 75% perceived the quality of the feedback to be good to excellent; 64% felt receiving feedback via the app improved their performance; 69% indicated the feedback method as better compared to other methods. Students acknowledged the facilitation of conversation with supervisors and the convenience of receiving feedback, as well as the promptness with which feedback was provided. The use of a drop-down menu was thought to limit the scope of conversation. These data point to the effectiveness of this method to cue supervisors to provide feedback to students.
Vacuum and the electron tube industry
NASA Astrophysics Data System (ADS)
Redhead, P. A.
2005-07-01
The electron tube industry started with the patenting of the thermionic diode by John Ambrose Fleming in 1904. The vacuum technology used by the infant tube industry was copied from the existing incandescent lamp industry. The growing demands for electron tubes for the military in the first world war led to major improvements in pumps and processing methods. By the 1920s, mass production methods were developing to satisfy the demands for receiving tubes by the burgeoning radio industry. Further expansion in the 1930s and 1940s resulted in improvements in automatic equipment for pumping vacuum tubes leading to the massive production rates of electron tubes in the second world war and the following two decades. The demand for radar during the war resulted in the development of techniques for large-scale production of microwave tubes and CRTs, the latter technology being put to good use later in TV picture tube production. The commercial introduction of the transistor ended the massive demand for receiving tubes. This review concentrates on the vacuum technology developed for receiving tube production.
Radiation energy conversion in space
NASA Technical Reports Server (NTRS)
Billman, K. W.
1979-01-01
Topics discussed at the third NASA conference on radiant energy conversion are reviewed. The unconcentrated-photovoltaic-generation version of a solar power satellite is described, noting that it will consist of a 21.3 x 5.3-sq-km silicon-solar-cell array expected to provide 17 Gw of electrical power, with 1 km in diam transmitters oriented to beam 2.45 GHz microwave power to two receiving/rectifying 'rectennas' on earth. The Solares space-energy-system concept, designed for providing a large fraction of the world's energy needs at costs comparable to those of future coal/nuclear alternative, is considered, as are subsystems for improving the economics of the solar power satellite. A concept proposing the use of relativistic-electron-storage rings for electron-beam energy transmission and storage, and a report on the production of a high temperature plasma with concentrated solar radiation are taken into account. Laser-conversion systems, including the direct-solar-pumped space laser, and the telec-powered spacecraft, are discussed.
NASA Technical Reports Server (NTRS)
Couturier, P.; Hoang, S.; Meyer-Vernet, N.; Steinberg, J. L.
1983-01-01
The ISEE-3 SBH radio receiver has provided the first systematic observations of the quasi-thermal (plasma waves) noise in the solar wind plasma. The theoretical interpretation of that noise involves the particle distribution function so that electric noise measurements with long antennas provide a fast and independent method of measuring plasma parameters: densities and temperatures of a two component (core and halo) electron distribution function have been obtained in that way. The polarization of that noise is frequency dependent and sensitive to the drift velocity of the electron population. Below the plasma frequency, there is evidence of a weak noise spectrum with spectral index -1 which is not yet accounted for by the theory. The theoretical treatment of the noise associated with the low energy (thermal) proton population shows that the moving electrical antenna radiates in the surrounding plasma by Carenkov emission which becomes predominant at the low frequencies, below about 0.1 F sub P.
Radiation energy conversion in space
DOE Office of Scientific and Technical Information (OSTI.GOV)
Billman, K.W.
1979-03-01
Topics discussed at the third NASA conference on radiant energy conversion are reviewed. The unconcentrated-photovoltaic-generation version of a solar power satellite is described, noting that it will consist of a 21.3 x 5.3-sq-km silicon-solar-cell array expected to provide 17 Gw of electrical power, with 1 km in diam transmitters oriented to beam 2.45 GHz microwave power to two receiving/rectifying 'rectennas' on earth. The Solares space-energy-system concept, designed for providing a large fraction of the world's energy needs at costs comparable to those of future coal/nuclear alternative, is considered, as are subsystems for improving the economics of the solar power satellite.more » A concept proposing the use of relativistic-electron-storage rings for electron-beam energy transmission and storage, and a report on the production of a high temperature plasma with concentrated solar radiation are taken into account. Laser-conversion systems, including the direct-solar-pumped space laser, and the telec-powered spacecraft, are discussed.« less
RF surface receive array coils: the art of an LC circuit.
Fujita, Hiroyuki; Zheng, Tsinghua; Yang, Xiaoyu; Finnerty, Matthew J; Handa, Shinya
2013-07-01
The radiofrequency (RF) receive array coil is a complicated device with many inductors and capacitors and serves as one of the most critical magnetic resonance imaging (MRI) electronic devices. It directly determines the achievable level of signal-to-noise ratio (SNR). Simply put, however, the RF coil is nothing but an LC circuit. The receive array coil was first proposed more than 20 years ago, evolving from a simple arrangement with a few electronic channels to a complicated system of 128 channels, enabling highly sophisticated parallel imaging, at different field strengths. This article summarizes the basic concepts pertaining to RF receive coil arrays and their associated SNR and reviews the theories behind the major components of such arrays. This includes discussions of the intrinsic SNR of a receive coil, the matching circuits, low-noise preamplifiers, coupling/decoupling amongst coils, the coupling between receive and transmit coils, decoupling via preamplifiers, and baluns. An 8-channel receive array coil on a cylindrical former serves as a useful example for demonstrating various points in the review. Copyright © 2013 Wiley Periodicals, Inc.
Brown, Kathleen M; Hirshon, Jon Mark; Alcorta, Richard; Weik, Tasmeen S; Lawner, Ben; Ho, Shiu; Wright, Joseph L
2014-01-01
In 2008, the National Highway Traffic Safety Administration funded the development of a model process for the development and implementation of evidence-based guidelines (EBGs) for emergency medical services (EMS). We report on the implementation and evaluation of an evidence-based prehospital pain management protocol developed using this model process. An evidence-based protocol for prehospital management of pain resulting from injuries and burns was reviewed by the Protocol Review Committee (PRC) of the Maryland Institute for Emergency Medical Services Systems (MIEMSS). The PRC recommended revisions to the Maryland protocol that reflected recommendations in the EBG: weight-based dosing and repeat dosing of morphine. A training curriculum was developed and implemented using Maryland's online Learning Management System and successfully accessed by 3,941 paramedics and 15,969 BLS providers. Field providers submitted electronic patient care reports to the MIEMSS statewide prehospital database. Inclusion criteria were injured or burned patients transported by Maryland ambulances to Maryland hospitals whose electronic patient care records included data for level of EMS provider training during a 12-month preimplementation period and a 12-month postimplementation period from September 2010 through March 2012. We compared the percentage of patients receiving pain scale assessments and morphine, as well as the dose of morphine administered and the use of naloxone as a rescue medication for opiate use, before and after the protocol change. No differences were seen in the percentage of patients who had a pain score documented or the percent of patients receiving morphine before and after the protocol change, but there was a significant increase in the total dose and dose in mg/kg administered per patient. During the postintervention phase, patients received an 18% higher total morphine dose and a 14.9% greater mg/kg dose. We demonstrated that the implementation of a revised statewide prehospital pain management protocol based on an EBG developed using the National Prehospital Evidence-based Guideline Model Process was associated with an increase in dosing of narcotic pain medication consistent with that recommended by the EBG. No differences were seen in the percentage of patients receiving opiate analgesia or in the documentation of pain scores.
48 CFR 1446.670 - Inspection, receiving and acceptance reports.
Code of Federal Regulations, 2014 CFR
2014-10-01
... each commercial shipping document or packing list, whether by manual or electronic means, for supplies... INTERIOR CONTRACT MANAGEMENT QUALITY ASSURANCE Material Inspection and Receiving Reports 1446.670...
48 CFR 1446.670 - Inspection, receiving and acceptance reports.
Code of Federal Regulations, 2012 CFR
2012-10-01
... each commercial shipping document or packing list, whether by manual or electronic means, for supplies... INTERIOR CONTRACT MANAGEMENT QUALITY ASSURANCE Material Inspection and Receiving Reports 1446.670...
48 CFR 1446.670 - Inspection, receiving and acceptance reports.
Code of Federal Regulations, 2010 CFR
2010-10-01
... each commercial shipping document or packing list, whether by manual or electronic means, for supplies... INTERIOR CONTRACT MANAGEMENT QUALITY ASSURANCE Material Inspection and Receiving Reports 1446.670...
48 CFR 1446.670 - Inspection, receiving and acceptance reports.
Code of Federal Regulations, 2013 CFR
2013-10-01
... each commercial shipping document or packing list, whether by manual or electronic means, for supplies... INTERIOR CONTRACT MANAGEMENT QUALITY ASSURANCE Material Inspection and Receiving Reports 1446.670...
48 CFR 1446.670 - Inspection, receiving and acceptance reports.
Code of Federal Regulations, 2011 CFR
2011-10-01
... each commercial shipping document or packing list, whether by manual or electronic means, for supplies... INTERIOR CONTRACT MANAGEMENT QUALITY ASSURANCE Material Inspection and Receiving Reports 1446.670...
Guan, Xiaoqian; Chen, Shuai; Voon, Chia Pao; Wong, Kam-Bo; Tikkanen, Mikko; Lim, Boon L
2018-01-01
Plant-type ferredoxins in Arabidopsis transfer electrons from the photosystem I to multiple redox-driven enzymes involved in the assimilation of carbon, nitrogen, and sulfur. Leaf-type ferredoxins also modulate the switch between the linear and cyclic electron routes of the photosystems. Recently, two novel ferredoxin homologs with extra C-termini were identified in the Arabidopsis genome (AtFdC1, AT4G14890; AtFdC2, AT1G32550). FdC1 was considered as an alternative electron acceptor of PSI under extreme ferredoxin-deficient conditions. Here, we showed that FdC1 could interact with some, but not all, electron acceptors of leaf-type Fds, including the ferredoxin-thioredoxin reductase (FTR), sulfite reductase (SiR), and nitrite reductase (NiR). Photoreduction assay on cytochrome c and enzyme assays confirmed its capability to receive electrons from PSI and donate electrons to the Fd-dependent SiR and NiR but not to the ferredoxin-NADP + oxidoreductase (FNR). Hence, FdC1 and leaf-type Fds may play differential roles by channeling electrons from photosystem I to different downstream electron acceptors in photosynthetic tissues. In addition, the median redox potential of FdC1 may allow it to receive electrons from FNR in non-photosynthetic plastids.
Guan, Xiaoqian; Chen, Shuai; Voon, Chia Pao; Wong, Kam-Bo; Tikkanen, Mikko; Lim, Boon L.
2018-01-01
Plant-type ferredoxins in Arabidopsis transfer electrons from the photosystem I to multiple redox-driven enzymes involved in the assimilation of carbon, nitrogen, and sulfur. Leaf-type ferredoxins also modulate the switch between the linear and cyclic electron routes of the photosystems. Recently, two novel ferredoxin homologs with extra C-termini were identified in the Arabidopsis genome (AtFdC1, AT4G14890; AtFdC2, AT1G32550). FdC1 was considered as an alternative electron acceptor of PSI under extreme ferredoxin-deficient conditions. Here, we showed that FdC1 could interact with some, but not all, electron acceptors of leaf-type Fds, including the ferredoxin-thioredoxin reductase (FTR), sulfite reductase (SiR), and nitrite reductase (NiR). Photoreduction assay on cytochrome c and enzyme assays confirmed its capability to receive electrons from PSI and donate electrons to the Fd-dependent SiR and NiR but not to the ferredoxin-NADP+ oxidoreductase (FNR). Hence, FdC1 and leaf-type Fds may play differential roles by channeling electrons from photosystem I to different downstream electron acceptors in photosynthetic tissues. In addition, the median redox potential of FdC1 may allow it to receive electrons from FNR in non-photosynthetic plastids. PMID:29670639
Surveillance for human Salmonella infections in the United States.
Swaminathan, Bala; Barrett, Timothy J; Fields, Patricia
2006-01-01
Surveillance for human Salmonella infections plays a critical role in understanding and controlling foodborne illness due to Salmonella. Along with its public health partners, the Centers for Disease Control and Prevention (CDC) has several surveillance systems that collect information on Salmonella infections in the United States. The National Salmonella Surveillance System, begun in 1962, receives reports of laboratory-confirmed Salmonella infections through state public health laboratories. Salmonella outbreaks are reported by state and local health departments through the Foodborne Disease Outbreak Reporting System, which became a Web-based, electronic system (eFORS) in 2001. PulseNet facilitates the detection of clusters of Salmonella infections through standardized molecular subtyping (DNA "fingerprinting") of isolates and maintenance of "fingerprint" databases. The National Antimicrobial Resistance Monitoring System for Enteric Bacteria (NARMS) monitors antimicrobial resistance in Salmonella by susceptibility testing of every 20th Salmonella isolate received by state and local public health laboratories. FootNet is an active surveillance system that monitors Salmonella infections in sentinel areas, providing population-based estimates of infection rates. Efforts are underway to electronically link all of the Salmonella surveillance systems at CDC to facilitate optimum use of available data and minimize duplication.
This procedure describes how to apply for and obtain approval of electronic reporting systems used to receive electronic documents in lieu of paper where the report is made pursuant to requirements or authority codified in CFR 40.
NASA Technical Reports Server (NTRS)
Yang, Jian-Xun; Agahi, Farid; Dai, Dong; Musante, Charles F.; Grammer, Wes; Lau, Kei M.; Yngvesson, K. S.
1993-01-01
This paper presents a new type of electron bolometric ('hot electron') mixer. We have demonstrated a 3 order-of-magnitude improvement in the bandwidth compared with previously known types of electron bolometric mixers, by using the two-dimensional electron gas (2DEG) medium at the heterointerface between AlGaAs and GaAs. We have tested both in-house MOCVD-grown material and MBE material, with similar results. The conversion loss (Lc) at 94 GHz is presently 18 dB for a mixer operating at 20 K, and calculations indicate that Lc can be decreased to about 10 dB in future devices. Calculated and measured curves of Lc versus P(LO), and I(DC), respectively, agree well. We argue that there are several different configurations of electron bolometric mixers, which will all show wide bandwidth, and that these devices are likely to become important as low-noise THz receivers in the future.
Ionosphere Threat Model Investigations by Using Turkish National Permanent GPS Network
NASA Astrophysics Data System (ADS)
Köroǧlu, Meltem; Arikan, Feza; Koroglu, Ozan
2016-07-01
Global Positioning System (GPS) signal realibity may decrease significantly due to the variable electron density structure of ionosphere. In the literature, ionospheric disturbance is modeled as a linear semi-definite wave which has width, gradient and a constant velocity. To provide precise positioning, Ground Based Augmentation Systems (GBAS) are used. GBAS collects all measurements from GPS network receivers and computes an integrity level for the measurement by comparing the network GPS receivers measurements with the threat models of ionosphere. Threat models are computed according to ionosphere gradient characteristics. Gradient is defined as the difference of slant delays between the receivers. Slant delays are estimated from the STEC (Slant Total Electron Content) values of the ionosphere that is given by the line integral of the electron density between the receiver and GPS satellite. STEC can be estimated over Global Navigation Satellite System (GNSS) signals by using IONOLAB-STEC and IONOLAB-BIAS algorithms. Since most of the ionospheric disturbance observed locally, threat models for the GBAS systems must be extracted as locally. In this study, an automated ionosphere gradient estimation algorithm was developed by using Turkish National Permanent GPS Network (TNPGN-Active) data for year 2011. The GPS receivers are grouped within 150 km radius. For each region, for each day and for each satellite all STEC values are estimated by using IONOLAB-STEC and IONOLAB-BIAS softwares (www.ionolab.org). In the gradient estimation, station-pair method is used. Statistical properties of the valid gradients are extracted as tables for each region, day and satellite. By observing the histograms of the maximum gradients and standard deviations of the gradients with respect to the elevation angle for each day, the anomalies and disturbances of the ionosphere can be detected. It is observed that, maximum gradient estimates are less than 40 mm/km and maximum standard deviation of the gradients are observed as 5 mm/km. In the stormy days, the level of gradients and the standard deviation values becomes larger than those of quiet days. These observations may also form a basis for the estimationof velocity and width of the traveling ionospheric disturbances. The study is supported by TUBITAK 115E915 and Joint TUBITAK 114E092 and AS CR14/001 projects.
Design and first plasma measurements of the ITER-ECE prototype radiometer.
Austin, M E; Brookman, M W; Rowan, W L; Danani, S; Bryerton, E W; Dougherty, P
2016-11-01
On ITER, second harmonic optically thick electron cyclotron emission (ECE) in the range of 220-340 GHz will supply the electron temperature (T e ). To investigate the requirements and capabilities prescribed for the ITER system, a prototype radiometer covering this frequency range has been developed by Virginia Diodes, Inc. The first plasma measurements with this instrument have been carried out on the DIII-D tokamak, with lab bench tests and measurements of third through fifth harmonic ECE from high T e plasmas. At DIII-D the instrument shares the transmission line of the Michelson interferometer and can simultaneously acquire data. Comparison of the ECE radiation temperature from the absolutely calibrated Michelson and the prototype receiver shows that the ITER radiometer provides accurate measurements of the millimeter radiation across the instrument band.
Synaptic organic transistors with a vacuum-deposited charge-trapping nanosheet
Kim, Chang-Hyun; Sung, Sujin; Yoon, Myung-Han
2016-01-01
Organic neuromorphic devices hold great promise for unconventional signal processing and efficient human-machine interfaces. Herein, we propose novel synaptic organic transistors devised to overcome the traditional trade-off between channel conductance and memory performance. A vacuum-processed, nanoscale metallic interlayer provides an ultra-flat surface for a high-mobility molecular film as well as a desirable degree of charge trapping, allowing for low-temperature fabrication of uniform device arrays on plastic. The device architecture is implemented by widely available electronic materials in combination with conventional deposition methods. Therefore, our results are expected to generate broader interests in incorporation of organic electronics into large-area neuromorphic systems, with potential in gate-addressable complex logic circuits and transparent multifunctional interfaces receiving direct optical and cellular stimulation. PMID:27645425
Radiology reporting: a closed-loop cycle from order entry to results communication.
Weiss, David L; Kim, Woojin; Branstetter, Barton F; Prevedello, Luciano M
2014-12-01
With the increasing prevalence of PACS over the past decade, face-to-face image review among health care providers has become a rarity. This change has resulted in increasing dependence on fast and accurate communication in radiology. Turnaround time expectations are now conveyed in minutes rather than hours or even days. Ideal modern radiology communication is a closed-loop cycle with multiple interoperable applications contributing to the final product. The cycle starts with physician order entry, now often performed through the electronic medical record, with clinical decision support to ensure that the most effective imaging study is ordered. Radiology reports are now almost all in electronic format. The majority are produced using speech recognition systems. Optimization of this software use can alleviate some, if not all, of the inherent user inefficiencies in this type of reporting. Integrated third-party software applications that provide data mining capability are extremely helpful in both academic and clinical settings. The closed-loop ends with automated communication of imaging results. Software products for this purpose should facilitate use of levels of alert, automated escalation to providers, and recording of audit trails of reports received. The multiple components of reporting should be completely interoperable with each other, as well as with the PACS, the RIS, and the electronic medical record. This integration will maximize radiologist efficiency and minimize the possibility of communication error. Copyright © 2014. Published by Elsevier Inc.
Rocket radio measurement of electron density in the nighttime ionosphere
NASA Technical Reports Server (NTRS)
Gilchrist, B. E.; Smith, L. G.
1979-01-01
One experimental technique based on the Faraday rotation effect of radio waves is presented for measuring electron density in the nighttime ionosphere at midlatitudes. High frequency linearly-polarized radio signals were transmitted to a linearly-polarized receiving system located in a spinning rocket moving through the ionosphere. Faraday rotation was observed in the reference plane of the rocket as a change in frequency of the detected receiver output. The frequency change was measured and the information was used to obtain electron density data. System performance was evaluated and some sources of error were identified. The data obtained was useful in calibrating a Langmuir probe experiment for electron density values of 100/cu cm and greater. Data from two rocket flights are presented to illustrate the experiment.
Mindell, Jodi A; Sedmak, Rebecca; Boyle, Julia T; Butler, Rachel; Williamson, Ariel A
2016-12-15
Socioeconomically disadvantaged children are at risk for poor sleep hygiene and increased sleep problems. This pilot study examined the efficacy of Sleep Well!, a parent-based sleep education endeavor, which supplemented an outreach program that provides beds to socioeconomically disadvantaged children. In addition to receiving a bed, 152 children (mean age = 5.95 years, 57.2% boys) were randomly assigned to sleep education (3 messages: bedtime before 21:00; no caffeine; keep electronics out of the bedroom) or control (dental hygiene education) conditions. All education was provided at both the time of scheduling and delivery of a bed to each child. Parent-reported sleep data were collected at baseline and at 4-week follow-up. Provision of a bed was associated with reduced bedroom electronics and increased parent-reported nighttime sleep duration for all children. However, relative to control children, intervention children showed even greater reductions in electronics (baseline mean = 1.91 items, follow-up mean = 0.85 items) and improvements in sleep duration (baseline mean = 9.75 hours, follow-up mean = 10.19 hours). There was no intervention effect for caffeine consumption or bedtime from baseline to follow-up. Providing beds to socioeconomically disadvantaged children resulted in increased sleep duration and decreased use of electronics at bedtime, while the combination of a bed and brief parent sleep education conferred additional sleep benefits. Further study of brief child sleep interventions is warranted, particularly among socioeconomically disadvantaged children who are at risk for sleep problems. © 2016 American Academy of Sleep Medicine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salem, Ahmed, E-mail: ahmed.salem@doctors.org.uk; Mohamad, Issa; Dayyat, Abdulmajeed
2015-10-01
Radiation pneumonitis is a well-documented side effect of radiation therapy for breast cancer. The purpose of this study was to compare combined photon-electron, photon-only, and electron-only plans in the radiation treatment of the supraclavicular lymph nodes. In total, 13 patients requiring chest wall and supraclavicular nodal irradiation were planned retrospectively using combined photon-electron, photon-only, and electron-only supraclavicular beams. A dose of 50 Gy over 25 fractions was prescribed. Chest wall irradiation parameters were fixed for all plans. The goal of this planning effort was to cover 95% of the supraclavicular clinical target volume (CTV) with 95% of the prescribed dosemore » and to minimize the volume receiving ≥ 105% of the dose. Comparative end points were supraclavicular CTV coverage (volume covered by the 95% isodose line), hotspot volume, maximum radiation dose, contralateral breast dose, mean total lung dose, total lung volume percentage receiving at least 20 Gy (V{sub 20} {sub Gy}), heart volume percentage receiving at least 25 Gy (V{sub 25} {sub Gy}). Electron and photon energies ranged from 8 to 18 MeV and 4 to 6 MV, respectively. The ratio of photon-to-electron fractions in combined beams ranged from 5:20 to 15:10. Supraclavicular nodal coverage was highest in photon-only (mean = 96.2 ± 3.5%) followed closely by combined photon-electron (mean = 94.2 ± 2.5%) and lowest in electron-only plans (mean = 81.7 ± 14.8%, p < 0.001). The volume of tissue receiving ≥ 105% of the prescription dose was higher in the electron-only (mean = 69.7 ± 56.1 cm{sup 3}) as opposed to combined photon-electron (mean = 50.8 ± 40.9 cm{sup 3}) and photon-only beams (mean = 32.2 ± 28.1 cm{sup 3}, p = 0.114). Heart V{sub 25} {sub Gy} was not statistically different among the plans (p = 0.999). Total lung V{sub 20} {sub Gy} was lowest in electron-only (mean = 10.9 ± 2.3%) followed by combined photon-electron (mean = 13.8 ± 2.3%) and highest in photon-only plans (mean = 16.2 ± 3%, p < 0.001). As expected, photon-only plans demonstrated the highest target coverage and total lung V{sub 20} {sub Gy}. The superiority of electron-only beams, in terms of decreasing lung dose, is set back by the dosimetric hotspots associated with such plans. Combined photon-electron treatment is a feasible technique for supraclavicular nodal irradiation and results in adequate target coverage, acceptable dosimetric hotspot volume, and slightly reduced lung dose.« less
Comparison of plasmaspheric electron content over sea and land using Jason-2 observations
NASA Astrophysics Data System (ADS)
Gulyaeva, Tamara; Cherniak, Iurii; Zakharenkova, Irina
2016-07-01
The Global Ionospheric Maps of Total Electron Content, GIM-TEC, may suffer from model assumptions, in particular, over the oceans where relatively few measurements are available due to a scarcity of ground-based GPS receivers network only on seashores and islands which involve more assumptions or interpolations imposed on GIM mapping techniques. The GPS-derived TEC represents the total electron content integrated through the ionosphere, iTEC, and the plasmasphere, pTEC. The sea/land differences in the F2 layer peak electron density, NmF2, and the peak height, hmF2, gathered with topside sounding data exhibit tilted ionosphere along the seashores with denser electron population at greater peak heights over the sea. Derivation of a sea/land proportion of total electron content from the new source of the satellite-based measurements would allow improve the mapping GIM-TEC products and their assimilation by the ionosphere-plasmasphere IRI-Plas model. In this context the data of Jason-2 mission provided through the NOAA CLASS Website (http://www.nsof.class.noaa.gov/saa/products/catSearch) present a unique database of pTEC measured through the plasmasphere over the Jason-2 orbit (1335 km) to GPS orbit (20,200 km) which become possible from GPS receivers placed onboard of Jason-2 with a zenith looking antenna that can be used not only for precise orbit determination (POD), but can also provide new data on the plasma density distribution in the plasmasphere. Special interest represents possibility of the potential increase of the data volume in two times due to the successful launch of the Jason-3 mission on 17 January 2016. The present study is focused on a comparison of plasmasphere electron content, pTEC, over the sea and land with a unique data base of the plasmasphere electron content, pTEC, using measurements onboard Jason-2 satellite during the solar minimum (2009) and solar maximum (2014). Slant TEC values were scaled to estimate vertical pTEC using a geometric factor derived by assuming the plasma occupies a spherical thin shell at 1400 km. The elevation angle cut-off was selected as 40 deg. Global distribution of POD TEC values has been presented in the form of pTEC maps, that were made by projecting the pTEC values on the Earth from the ionosphere pierce point at the shell altitude. Along the satellite pass for each epoch we have pTEC values for several linked LEO-GPS simultaneously, that can be binned and averaged into map cells. Results of pTEC maps analysis in terms of local time, season and solar activity are presented in the paper.
Integration and test of high-speed transmitter electronics for free-space laser communications
NASA Technical Reports Server (NTRS)
Soni, Nitin J.; Lizanich, Paul J.
1994-01-01
The NASA Lewis Research Center in Cleveland, Ohio, has developed the electronics for a free-space, direct-detection laser communications system demonstration. Under the High-Speed Laser Integrated Terminal Electronics (Hi-LITE) Project, NASA Lewis has built a prototype full-duplex, dual-channel electronics transmitter and receiver operating at 325 megabit S per second (Mbps) per channel and using quaternary pulse-position modulation (QPPM). This paper describes the integration and testing of the transmitter portion for future application in free-space, direct-detection laser communications. A companion paper reviews the receiver portion of the prototype electronics. Minor modifications to the transmitter were made since the initial report on the entire system, and this paper addresses them. The digital electronics are implemented in gallium arsenide integrated circuits mounted on prototype boards. The fabrication and implementation issues related to these high-speed devices are discussed. The transmitter's test results are documented, and its functionality is verified by exercising all modes of operation. Various testing issues pertaining to high-speed circuits are addressed. A description of the transmitter electronics packaging concludes the paper.
All-Optical Ultrasound Transducers for High Resolution Imaging
NASA Astrophysics Data System (ADS)
Sheaff, Clay Smith
High frequency ultrasound (HFUS) has increasingly been used within the past few decades to provide high resolution (< 200 mum) imaging in medical applications such as endoluminal imaging, intravascular imaging, ophthalmology, and dermatology. The optical detection and generation of HFUS using thin films offers numerous advantages over traditional piezoelectric technology. Circumvention of an electronic interface with the device head is one of the most significant given the RF noise, crosstalk, and reduced capacitance that encumbers small-scale electronic transducers. Thin film Fabry-Perot interferometers - also known as etalons - are well suited for HFUS receivers on account of their high sensitivity, wide bandwidth, and ease of fabrication. In addition, thin films can be used to generate HFUS when irradiated with optical pulses - a method referred to as Thermoelastic Ultrasound Generation (TUG). By integrating a polyimide (PI) film for TUG into an etalon receiver, we have created for the first time an all-optical ultrasound transducer that is both thermally stable and capable of forming fully sampled 2-D imaging arrays of arbitrary configuration. Here we report (1) the design and fabrication of PI-etalon transducers; (2) an evaluation of their optical and acoustic performance parameters; (3) the ability to conduct high-resolution imaging with synthetic 2-D arrays of PI-etalon elements; and (4) work towards a fiber optic PI-etalon for in vivo use. Successful development of a fiber optic imager would provide a unique field-of-view thereby exposing an abundance of prospects for minimally-invasive analysis, diagnosis, and treatment of disease.
An optimal user-interface for EPIMS database conversions and SSQ 25002 EEE parts screening
NASA Technical Reports Server (NTRS)
Watson, John C.
1996-01-01
The Electrical, Electronic, and Electromechanical (EEE) Parts Information Management System (EPIMS) database was selected by the International Space Station Parts Control Board for providing parts information to NASA managers and contractors. Parts data is transferred to the EPIMS database by converting parts list data to the EP1MS Data Exchange File Format. In general, parts list information received from contractors and suppliers does not convert directly into the EPIMS Data Exchange File Format. Often parts lists use different variable and record field assignments. Many of the EPES variables are not defined in the parts lists received. The objective of this work was to develop an automated system for translating parts lists into the EPIMS Data Exchange File Format for upload into the EPIMS database. Once EEE parts information has been transferred to the EPIMS database it is necessary to screen parts data in accordance with the provisions of the SSQ 25002 Supplemental List of Qualified Electrical, Electronic, and Electromechanical Parts, Manufacturers, and Laboratories (QEPM&L). The SSQ 2S002 standards are used to identify parts which satisfy the requirements for spacecraft applications. An additional objective for this work was to develop an automated system which would screen EEE parts information against the SSQ 2S002 to inform managers of the qualification status of parts used in spacecraft applications. The EPIMS Database Conversion and SSQ 25002 User Interfaces are designed to interface through the World-Wide-Web(WWW)/Internet to provide accessibility by NASA managers and contractors.
NASA Astrophysics Data System (ADS)
Kutiev, Ivan; Marinov, Pencho; Fidanova, Stefka; Belehaki, Anna; Tsagouri, Ioanna
2012-12-01
Validation results on the latest version of TaD model (TaDv2) show realistic reconstruction of the electron density profiles (EDPs) with an average error of 3 TECU, similar to the error obtained from GNSS-TEC calculated paremeters. The work presented here has the aim to further improve the accuracy of the TaD topside reconstruction, adjusting the TEC parameter calculated from TaD model with the TEC parameter calculated by GNSS transmitting RINEX files provided by receivers co-located with the Digisondes. The performance of the new version is tested during a storm period demonstrating further improvements in respect to the previous version. Statistical comparison of modeled and observed TEC confirms the validity of the proposed adjustment. A significant benefit of the proposed upgrade is that it facilitates the real-time implementation of TaD. The model needs a reliable measure of the scale height at the peak height, which is supposed to be provided by Digisondes. Oftenly, the automatic scaling software fails to correctly calculate the scale height at the peak, Hm, due to interferences in the receiving signal. Consequently the model estimated topside scale height is wrongly calculated leading to unrealistic results for the modeled EDP. The proposed TEC adjustment forces the model to correctly reproduce the topside scale height, despite the inaccurate values of Hm. This adjustment is very important for the application of TaD in an operational environment.
NASA Astrophysics Data System (ADS)
Prilepskiy, Yuriy
2007-03-01
This paper presents continuation data of the series of experiments with the electron gun of the CEBAF machine at Jefferson Lab (Newport News, VA), which is capable of delivering electrons with energies up to 200 keV. This 1.5 GHz beam permits to generate cellular damage within minutes. We have performed irradiation of cancer and normal cells with different electron energies and currents to investigate cell biological responses. The biological response is measured through proteomics analysis before and after irradiation. The living cells are encased in special air containers allowing proper positioning in vacuum where the electrons are present. The containers receive the irradiation from the mono energetic electrons with energy up to 120 keV, resulting in an irradiation from both electrons and a small number of photons from the original beam passing through the thin container window. This window allows approximately half of the beam to come through. The study will permit to address the physical processes involved in the RBE and LET at a level that supersedes current data listed in the literature. We will discuss the experimental setup and the second stage of data collected with the new more developed system. This research is part of a global program to provide detailed information for the understanding of radiation based cancer treatments.
Satellite and ground based observations of a large-scale electron precipitation event
NASA Astrophysics Data System (ADS)
Gamble, R. J.; Rodger, C. J.; Clilverd, M.; Thomson, N. R.; Ulich, T.; Parrot, M.; Sauvaud, J.; Berthelier, J.
2010-12-01
In order to describe how geomagnetic storms couple to the upper atmosphere, and hence to atmospheric chemistry and dynamics, measurements are required of energetic electron precipitation into the atmosphere. However, satellite observations are currently poorly suited to providing measurements of energetic and relativistic electron precipitation. The AARDDVARK network (Antarctic-Arctic Radiation-belt (Dynamic) Deposition - VLF Atmospheric Research Konsortium) provides continuous long-range observations of ionisation levels from ~30-85 km altitude, with the goal of increasing the understanding of energy coupling between the Earth's atmosphere, Sun, and Space. In this study we combine AARDDVARK subionospheric VLF measurements with DEMETER electron spectra using modelling techniques to study >100 keV energetic and relativistic electron precipitation into the atmosphere for the 24-hour period beginning 0600UT 19 January during the 17-21 January 2005 geomagnetic storms. The study augments large-scale regional observations using VLF measurements of multiple subionospheric paths to our receiver at Sodankylä, Finland (67.4°N, 26.6°E, L=5.31), combined with detailed in situ measurements from the DEMETER satellite to allow the spatial extent, flux, and energy distribution of the precipitation to be determined. In contrast to other satellites, DEMETER’s electron spectrometer has excellent energy resolution. The DEMETER-measured precipitation spectrum is used to infer an altered electron density profile, modelled using a simple ionospheric electron model. This altered electron profile is then used in a subionospheric VLF model and compared with AARDDVARK VLF results. Matching model results with subionospheric VLF measurements allows calculation of both the intensity and geographic extent (in L) of the precipitation region required to produce such an effect. We find that a flux of 7000 elec.cm-2s-1 >100 keV electrons precipitates into the atmosphere over an L range of 3.5-4.0. An error analysis is also included. By providing a better picture of both the intensity and size of the precipitation region, we obtain a more complete picture of the net impact that such a precipitation event has on the upper atmosphere. The results of this analysis will become primary inputs to chemical modelling of the impact that this precipitation has on the neutral atmosphere.
Lesson 3: Attorney General (AG) Certification
The AG Certification is a letter confirming legal authority to implement the electronic reporting covered by the application and enforce the affected programs using the electronic documents received under those programs.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-04
... INTERNATIONAL TRADE COMMISSION [Docket No. 2898] Certain Electronic Imaging Devices Corrected.... International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that the U.S. International Trade Commission has received a complaint entitled Certain Electronic Imaging Devices, DN 2898; the...
50 CFR 660.113 - Trawl fishery-recordkeeping and reporting.
Code of Federal Regulations, 2010 CFR
2010-10-01
... estimates of fish weights or species composition, shall not be submitted on electronic fish tickets. (vi... necessary by the Regional Administrator as specified on the appropriate electronic fish ticket form. (iv) Electronic fish ticket submissions. The Pacific whiting shoreside first receiver must: (A) Sort all fish...
NASA Astrophysics Data System (ADS)
Tan, J. H.; Cohen, M.; Inan, U. S.; Scherrer, P. H.; Scherrer, D.
2005-12-01
Stanford University Very Low Frequency (VLF) and Extremely Low Frequency (ELF) radio receivers have been used extensively for remote sensing of the ionosphere and the magnetosphere. Among the phenomena that can be uniquely measured via ELF/VLF receivers are radio atmospherics, whistlers, electron precipitation, solar flares, sudden ionospheric disturbances, gravity waves, sprites, and cosmic gamma-ray flares. With the use of simple square air-core magnetic loop antennas of a couple of meters in size, the sensitivity of these instruments allows the measurement of magnetic fields as low as several tens of femtoTesla per root-Hz, in the frequency range of ~30 Hz to 50 kHz. This sensitivity well exceeds that required to detect any event above the ambient atmospheric noise floor, determined by the totality of lightning activity on the planet. In recent years, as cost of production, timing accuracy (due to low cost GPS clocks), and data handling flexibility of the systems has improved, it has become possible to distribute many of these instruments in the form of arrays, to perform interferometric and holographic imaging of the lower ionosphere. In the context of the IHY in 2007, the ELF/VLF receiver can used extensively as part of the United Nations initiative to place scientific instruments in developing countries. Stanford University's past experiences setting up arrays of ELF/VLF receivers include an interferometer in Alaska, the Holographic Array for Ionospheric and Lightning research (HAIL) consisting of instruments at 13 different high schools in mid-western United States, a broader set of ELF/VLF receivers in Alaska, and various receivers abroad, including in France, Japan, Greece, Turkey, Ireland, and India. A global network of ELF/VLF receivers offer possibilities for a wide range of scientific topics, as well as serving as a means for educational outreach. These goals will be achieved using the newest version of the Stanford VLF receiver, known as AWESOME: Atmospheric Weather Educational System for Observation and Modeling of Electromagnetics. This new version is substantially lower in cost, and easier to set-up and use. Nevertheless, the receivers offer the same ultimate levels of resolution in time, sensitivity and dynamic range, as well as ease of handling of data that is used by researchers conducting cutting edge ionospheric and magnetospheric research. In this context, the placement of these systems at underdeveloped host countries provides an open-ended potential for exploration, limited only by the imagination and drive of the users. AWESOME monitors can be placed at schools, or universities, where they will serve the dual purpose of advancing scientific research, as well as providing a valuable tool for scientific education. Data collected can be pooled and publicly available to all the sites, strengthening the potential for both cooperative education and collaboration on the science between various regions and locations.
UAVSAR Active Electronically-Scanned Array
NASA Technical Reports Server (NTRS)
Sadowy, Gregory; Brown, Kyle; Chamberlain, Neil; Figueroa, Harry; Fisher, Charlie; Grando, Maurio; Hamilton, Gary; Vorperian, Vatche; Zawadzki, Mark
2010-01-01
The Uninhabited Airborne Vehicle Synthetic Aperture Radar (UAVSAR) L-band (1.2-1.3 GHz) repeat pass, interferometric synthetic aperture radar (InSAR) used for Earth science applications. Using complex radar images collected during separate passes on time scales of hours to years, changes in surface topography can be measured. The repeat-pass InSAR technique requires that the radar look angle be approximately the same on successive passes. Due to variations in aircraft attitude between passes, antenna beam steering is required to replicate the radar look angle. This paper describes an active, electronically steered array (AESA) that provides beam steering capability in the antenna azimuth plane. The array contains 24 transmit/receive modules generating 2800 W of radiated power and is capable of pulse-to-pulse beam steering and polarization agility. Designed for high reliability as well as serviceability, all array electronics are contained in single 178cm x 62cm x 12 cm air-cooled panel suitable for operation up 60,000 ft altitude.
Thermal and fluid simulation of the environment under the dashboard, compared with measurement data
NASA Astrophysics Data System (ADS)
Popescu, C. S.; Sirbu, G. M.; Nita, I. C.
2017-10-01
The development of vehicles during the last decade is related to the evolution of electronic systems added in order to increase the safety and the number of services available on board, such as advanced driver-assistance systems (ADAS). Cars already have a complex computer network, with electronic control units (ECUs) connected to each other and receiving information from many sensors. The ECUs transfer an important heat power to the environment, while proper operating conditions need to be provided to ensure their reliability at high and low temperature, vibration and humidity. In a car cabin, electronic devices are usually placed in the compartment under the dashboard, an enclosed space designed for functional purposes. In the early stages of the vehicle design it has become necessary to analyse the environment under dashboard, by the use of Computational Fluid Dynamics (CFD) simulations and measurements. This paper presents the cooling of heat sinks by natural convection, a thermal and fluid simulation of the environment under the dashboard compared with test data.
Separation of Intercepted Multi-Radar Signals Based on Parameterized Time-Frequency Analysis
NASA Astrophysics Data System (ADS)
Lu, W. L.; Xie, J. W.; Wang, H. M.; Sheng, C.
2016-09-01
Modern radars use complex waveforms to obtain high detection performance and low probabilities of interception and identification. Signals intercepted from multiple radars overlap considerably in both the time and frequency domains and are difficult to separate with primary time parameters. Time-frequency analysis (TFA), as a key signal-processing tool, can provide better insight into the signal than conventional methods. In particular, among the various types of TFA, parameterized time-frequency analysis (PTFA) has shown great potential to investigate the time-frequency features of such non-stationary signals. In this paper, we propose a procedure for PTFA to separate overlapped radar signals; it includes five steps: initiation, parameterized time-frequency analysis, demodulating the signal of interest, adaptive filtering and recovering the signal. The effectiveness of the method was verified with simulated data and an intercepted radar signal received in a microwave laboratory. The results show that the proposed method has good performance and has potential in electronic reconnaissance applications, such as electronic intelligence, electronic warfare support measures, and radar warning.
NASA Astrophysics Data System (ADS)
Liu, Yang; Li, Feng; Li, Xue Wen; Shi, Wen Yong
2018-03-01
Rolling is currently a widely used method for manufacturing and processing high-performance magnesium alloy sheets and has received widespread attention in recent years. Here, we combined continuous variable cross-section direct extrusion (CVCDE) and rolling processes. The microstructure and mechanical properties of the resulting sheets rolled at different temperatures from CVCDE extrudate were investigated by optical microscopy, scanning electron microscope, transmission electron microscopy and electron backscatter diffraction. The results showed that a fine-grained microstructure was present with an average grain size of 3.62 μm in sheets rolled from CVCDE extrudate at 623 K. Dynamic recrystallization and a large strain were induced by the multi-pass rolling, which resulted in grain refinement. In the 573-673 K range, the yield strength, tensile strength and elongation initially increased and then declined as the CVCDE temperature increased. The above results provide an important scientific basis of processing, manufacturing and the active control on microstructure and property for high-performance magnesium alloy sheet.
First results from the energetic particle instrument on the OEDIPUS-C sounding rocket
NASA Astrophysics Data System (ADS)
Gough, M. P.; Hardy, D. A.; James, H. G.
The Canadian / US OEDIPUS-C rocket was flown from the Poker Flat Rocket Range November 6th 1995 as a mother-son sounding rocket. It was designed to study auroral ionospheric plasma physics using active wave sounding and prove tether technology. The payload separated into two sections reaching a separation of 1200m along the Earth's magnetic field. One section included a frequency stepped HF transmitter and the other included a synchronised HF receiver. Both sections included Energetic Particle Instruments, EPI, stepped in energy synchronously with the transmitter steps. On-board EPI particle processing in both payloads provided direct measurements of electron heating, wave-particle interactions via particle correlators, and a high resolution measurement of wave induced particle heating via transmitter synchronised fast sampling. Strong electron heating was observed at times when the HF transmitter frequency was equal to a harmonic of the electron gyrofrequency, f_ce, or equal to the upper hybrid frequency, f_uh.
Otsuka, Shelley H.; Tayal, Neeraj H.; Porter, Kyle; Embi, Peter J.; Beatty, Stuart J.
2014-01-01
BACKGROUND Preventative health services, including herpes zoster vaccination rates, remain low despite known benefits. A new care model to improve preventative health services is warranted. The objective of this study is to investigate whether the functions of an electronic medical record, in combination with a pharmacist as part of the care team, can improve the herpes zoster vaccination rate. METHODS This study was a 6-month, randomized controlled trial at a General Internal Medicine clinic at The Ohio State University. The 2589 patients aged 60 years and older without documented herpes zoster vaccination in the electronic medical record were stratified on the basis of activated personal health record status, an online tool used to share health information between patient and provider. Of the 674 personal health record users, 250 were randomized to receive information regarding the herpes zoster vaccination via an electronic message and 424 were randomized to standard of care. Likewise, of the 1915 nonpersonal health record users, 250 were randomized to receive the same information via the US Postal Service and 1665 were randomized to standard of care. After pharmacist chart review, eligible patients were mailed a herpes zoster vaccine prescription. Herpes zoster vaccination rates were compared by chi-square tests. RESULTS Intervention recipients had significantly higher vaccination rates than controls in both personal health record (relative risk, 2.7; P = .0007) and nonpersonal health record (relative risk, 2.9; P = .0001) patient populations. CONCLUSIONS Communication outside of face-to-face office visits, by both personal health record electronic message and information by mail, can improve preventative health intervention rates compared with standard care. PMID:23830534
Results From YOUTHSAT - Indian experiment in earths thermosphere-ionosphere region.
NASA Astrophysics Data System (ADS)
Tarun Kumar, Pant
It is known that the characterization and modeling of the ionosphere/thermosphere necessitates a comprehensive understanding of the various processes prevailing therein. India’s first, indigenous and dedicated aeronomy satellite 'YOUTHSAT' carrying two Indian payloads - RaBIT (Radio Beacon for Ionospheric Tomography), and LiVHySI (Limb Viewing Hyper Spectral Imager) and one Russian payload SOLRAD, was conceived primarily to address to this aspect and launched on April 20, 2011 in an 818 Km polar orbit from SHAR on ISRO launch vehicle PSLV. The payloads RaBIT and LiVHySI were designed specifically to observe the ionised and neutral components of the upper atmosphere respectively. YOUTHSAT is a small satellite quiet advanced in its class having all the functionalities which are normally associated with a bigger satellite. The rising phase of the 23rd solar cycle was considered to be the best window for various observations from onboard YOUTHSAT. As an Indo Russian endeavour, it was launched with an objective of investigating the terrestrial upper atmosphere vis-a-vis the activity on the sun. RaBIT, an ISRO venture, is a radio beacon emitting coherent radio signal at 150 and 400 MHz frequencies. These are received using a chain of five receivers deployed along the ~76oE meridian at Trivandrum, Bangalore, Hyderabad, Bhopal and Delhi. The receivers estimate the Total Electron Content (TEC) of the ionosphere through the relative phase change of the received radio signals. The TECs thus estimated near simultaneously, are used to generate a tomogram, which gives an Altitude-Latitude distribution of the ionospheric electron density. For YOUTHSAT configuration, the tomogram covers the ionosphere from a few degrees (5-6o) south of Trivandrum to about 3-4o north of Delhi depending upon the satellite elevation. The RaBIT tomography network is by far the longest network existing anywhere in the world, and is unique therefore. Through RaBIT, a unique dataset leading to ionospheric tomograms representing altitude-latitude variation of electron density over the 77oE meridian over the Indian region has been generated around specific times (~10:30 AM/PM). These tomograms have provided, among others: (a) First ever images of the ionospheric nighttime ESF irregularities (b) Quantification of the topside F3 ionospheric layers using Tomography (c) Evidence of wavelike modulations in the overall low and equatorial ionospheric region using tomography (d) Day and night differences in the electron density distribution, (e) Evidence of the presence of the ionospheric top-side layer (f) Modulations in the ionosphere due to space weather activity and (g) Direct evidence of the presence of Travelling Atmospheric Disturbance (TAD). YOUTHSAT recently completed its mission life time of about two years, after having generated a comprehensive set of data on terrestrial upper atmosphere. The YOUTHSAT data are being analysed by various researchers and more results providing a new insight into the upper atmospheric processes are in offing. Some of the important outcomes mentioned above will be discussed in detail.
NASA Astrophysics Data System (ADS)
Durmaz, Murat; Karslioglu, Mahmut Onur
2015-04-01
There are various global and regional methods that have been proposed for the modeling of ionospheric vertical total electron content (VTEC). Global distribution of VTEC is usually modeled by spherical harmonic expansions, while tensor products of compactly supported univariate B-splines can be used for regional modeling. In these empirical parametric models, the coefficients of the basis functions as well as differential code biases (DCBs) of satellites and receivers can be treated as unknown parameters which can be estimated from geometry-free linear combinations of global positioning system observables. In this work we propose a new semi-parametric multivariate adaptive regression B-splines (SP-BMARS) method for the regional modeling of VTEC together with satellite and receiver DCBs, where the parametric part of the model is related to the DCBs as fixed parameters and the non-parametric part adaptively models the spatio-temporal distribution of VTEC. The latter is based on multivariate adaptive regression B-splines which is a non-parametric modeling technique making use of compactly supported B-spline basis functions that are generated from the observations automatically. This algorithm takes advantage of an adaptive scale-by-scale model building strategy that searches for best-fitting B-splines to the data at each scale. The VTEC maps generated from the proposed method are compared numerically and visually with the global ionosphere maps (GIMs) which are provided by the Center for Orbit Determination in Europe (CODE). The VTEC values from SP-BMARS and CODE GIMs are also compared with VTEC values obtained through calibration using local ionospheric model. The estimated satellite and receiver DCBs from the SP-BMARS model are compared with the CODE distributed DCBs. The results show that the SP-BMARS algorithm can be used to estimate satellite and receiver DCBs while adaptively and flexibly modeling the daily regional VTEC.
Application of GPS Measurements for Ionospheric and Tropospheric Modelling
NASA Astrophysics Data System (ADS)
Rajendra Prasad, P.; Abdu, M. A.; Furlan, Benedito. M. P.; Koiti Kuga, Hélio
military navigation. The DOD's primary purposes were to use the system in precision weapon delivery and providing a capability that would help reverse the proliferation of navigation systems in military. Subsequently, it was very quickly realized that civil use and scientific utility would far outstrip military use. A variety of scientific applications are uniquely suited to precise positioning capabilities. The relatively high precision, low cost, mobility and convenience of GPS receivers make positioning attractive. The other applications being precise time measurement, surveying and geodesy purposes apart from orbit and attitude determination along with many user services. The system operates by transmitting radio waves from satellites to receivers on the ground, aircraft, or other satellites. These signals are used to calculate location very accurately. Standard Positioning Services (SPS) which restricts access to Coarse/Access (C/A) code and carrier signals on the L1 frequency only. The accuracy thus provided by SPS fall short of most of the accuracy requirements of users. The upper atmosphere is ionized by the ultra violet radiation from the sun. The significant errors in positioning can result when the signals are refracted and slowed by ionospheric conditions, the parameter of the ionosphere that produces most effects on GPS signals is the total number of electrons in the ionospheric propagation path. This integrated number of electrons, called Total Electron Content (TEC) varies, not only from day to night, time of the year and solar flux cycle, but also with geomagnetic latitude and longitude. Being plasma the ionosphere affects the radio waves propagating through it. Effects of scintillation on GPS satellite navigation systems operating at L1 (1.5754 GHz), L2 (1.2276 GHz) frequencies have not been estimated accurately. It is generally recognized that GPS navigation systems are vulnerable in the polar and especially in the equatorial region during the solar maximum period. In the equatorial region the irregularity structures are highly elongated in the north-south direction and are discrete in the east-west direction with dimensions of several hundred km. With such spatial distribution of irregularities needs to determine how often the GPS receivers fails to provide navigation aid with the available constellation. The effects of scintillation on the performance of GPS navigation systems in the equatorial region can be analyzed through commissioning few ground receivers. Incidentally there are few GPS receivers near these latitudes. Despite the recent advances in the ionosphere and tropospheric delay modeling for geodetic applications of GPS, the models currently used are not very precise. The conventional and operational ionosphere models viz. Klobuchar, Bent, and IRI models have certain limitations in providing very precise accuracies at all latitudes. The troposphere delay modeling also suffers in accuracy. The advances made in both computing power and knowledge of the atmosphere leads to make an effort to upgrade some of these models for improving delay corrections in GPS navigation. The ionospheric group delay corrections for orbit determination can be minimized using duel frequency. However in single frequency measurements the group delay correction is an involved task. In this paper an investigation is carried out to estimate the model coefficients of ionosphere along with precise orbit determination modeling using GPS measurements. The locations of the ground-based receivers near equator are known very exactly. Measurements from these ground stations to a precisely known satellite carrying duel receiver is used for orbit determination. The ionosphere model parameters can be refined corresponding to spatially distributed GPS receivers spread over Brazil. The tropospheric delay effects are not significant for the satellites by choosing appropriate elevation angle. However it needs to be analyzed for user like aircraft for an effective use. In this paper brief description of GPS data utilization, Navigational message, orbit computation and precise orbit determination and Ionosphere and troposphere models are summarized. The methodology towards refining ionosphere model coefficients is presented. Some of the plots and results related to orbit determination are presented. The study demonstrated the feasibility of estimating ionosphere group delay at specific latitudes and could be improved through refining some of the model coefficients using GPS measurements. It is possible to accurately determine the tropospheric delay, which may be used for an aircraft in flight without access to real time meteorological information.
Electronic ferroelectricity induced by charge and orbital orderings.
Yamauchi, Kunihiko; Barone, Paolo
2014-03-12
After the revival of the magnetoelectric effect which took place in the early 2000s, the interest in multiferroic materials displaying simultaneous presence of spontaneous long-range magnetic and dipolar order has motivated an exponential growth of research activity, from both the experimental and theoretical perspectives. Within this context, and relying also on the rigorous formulation of macroscopic polarization as provided by the Berry-phase approach, it has been possible to identify new microscopic mechanisms responsible for the appearance of ferroelectricity. In particular, it has been realized that electronic spin, charge and orbital degrees of freedom may be responsible for the breaking of the space-inversion symmetry, a necessary condition for the appearance of electric polarization, even in centrosymmetric crystal structures. In view of its immediate potential application in magnetoelectric-based devices, many efforts have been made to understand how magnetic orderings may lead to ferroelectric polarization, and to identify candidate materials. On the other hand, the role of charge and orbital degrees of freedom, which have received much less attention, has been predicted to be non-negligible in several cases. Here, we review recent theoretical advances in the field of so-called electronic ferroelectricity, focusing on the possible mechanisms by which charge- and/or orbital-ordering effects may cause the appearance of macroscopic polarization. Generally, a naive distinction can be drawn between materials displaying almost localized electrons and those characterized by a strong covalent character and delocalized electrons. As for the latter, an intuitive understanding of basic mechanisms is provided in the framework of tight-binding model Hamiltonians, which are used to shed light on unusual charge/orbital effects in half-doped manganites, whereas the case of magnetite will be thoroughly discussed in light of recent progress pointing to an electronic origin of its proposed ferroelectric and magnetoelectric properties.
NASA Astrophysics Data System (ADS)
Boling, M. E.
1989-09-01
Prototypes were assembled pursuant to recommendations made in report K/DSRD-96, Issues and Approaches for Electronic Document Approval and Transmittal Using Digital Signatures and Text Authentication, and to examine and discover the possibilities for integrating available hardware and software to provide cost effective systems for digital signatures and text authentication. These prototypes show that on a LAN, a multitasking, windowed, mouse/keyboard menu-driven interface can be assembled to provide easy and quick access to bit-mapped images of documents, electronic forms and electronic mail messages with a means to sign, encrypt, deliver, receive or retrieve and authenticate text and signatures. In addition they show that some of this same software may be used in a classified environment using host to terminal transactions to accomplish these same operations. Finally, a prototype was developed demonstrating that binary files may be signed electronically and sent by point to point communication and over ARPANET to remote locations where the authenticity of the code and signature may be verified. Related studies on the subject of electronic signatures and text authentication using public key encryption were done within the Department of Energy. These studies include timing studies of public key encryption software and hardware and testing of experimental user-generated host resident software for public key encryption. This software used commercially available command-line source code. These studies are responsive to an initiative within the Office of the Secretary of Defense (OSD) for the protection of unclassified but sensitive data. It is notable that these related studies are all built around the same commercially available public key encryption products from the private sector and that the software selection was made independently by each study group.
27 CFR 73.31 - May I submit forms electronically to TTB?
Code of Federal Regulations, 2010 CFR
2010-04-01
... requirement in this chapter, only if: (a) We have published a notice in the Federal Register and on our Web... Register and on our Web site as stated above; (c) You submit the electronic form to an electronic document receiving system that we have designated for the receipt of that specific form; and (d) The electronic form...
Buurman, Bianca M; Verhaegh, Kim J; Smeulers, Marian; Vermeulen, Hester; Geerlings, Suzanne E; Smorenburg, Susanne; de Rooij, Sophia E
2016-06-01
To develop, implement and evaluate a personalized patient discharge letter (PPDL) to improve the quality of handoff communication from hospital to home. From the end of 2006-09 we conducted a quality improvement project; consisting of a before-after evaluation design, and a process evaluation. Four general internal medicine wards, in a 1024-bed teaching hospital in Amsterdam, the Netherlands. All consecutive patients of 18 years and older, admitted for at least 48 h. A PPDL, a plain language handoff communication tool provided to the patient at hospital discharge. Verbal and written information provision at discharge, feasibility of integrating the PPDL into daily practice, pass rates of PPDLs provided at discharge. A total of 141 patients participated in the before-after evaluation study. The results from the first phase of quality improvement showed that providing patient with a PPDL increased the number of patients receiving verbal and written information at discharge. Patient satisfaction with the PPDL was 7.3. The level of implementation was low (30%). In the second phase, the level of implementation improved because of incorporating the PPDL into the electronic patient record (EPR) and professional education. An average of 57% of the discharged patients received the PPDL upon discharge. The number of discharge conversations also increased. Patients and professionals rated the PPDL positively. Key success factors for implementation were: education of interns, residents and staff, standardization of the content of the PPDL, integrating the PPDL into the electronic medical record and hospital-wide policy. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care; all rights reserved.
Gray, Justin; Svikis, Dace S; Puder, Karoline S; Resnicow, Ken; Konkel, Janine; Rice, Shetoya; McGoron, Lucy; Ondersma, Steven J
2017-01-01
Background Marijuana is the most widely used illicit substance during pregnancy. Technology-delivered brief interventions and text messaging have shown promise in general and pregnant samples but have not yet been applied to marijuana use in pregnancy. Objective The objective of the study was to evaluate, among pregnant women and prenatal care providers, the acceptability of an electronic brief intervention and text messaging plan for marijuana use in pregnancy. Methods Participants included patients (n=10) and medical staff (n=12) from an urban prenatal clinic. Patient-participants were recruited directly during a prenatal care visit. Those who were eligible reviewed the interventions individually and provided quantitative and qualitative feedback regarding software acceptability and helpfulness during a one-on-one interview with research staff. Provider-participants took part in focus groups in which the intervention materials were reviewed and discussed. Qualitative and focus group feedback was transcribed, coded manually, and classified by category and theme. Results Patient-participants provided high ratings for satisfaction, with mean ratings for respectfulness, interest, ease of use, and helpfulness ranging between 4.4 and 4.7 on a 5-point Likert scale. Of the 10 participants, 5 reported that they preferred working with the program versus their doctor, and 9 of 10 said the intervention made them more likely to reduce their marijuana use. Provider-participants received the program favorably, stating the information presented was both relevant and important for their patient population. Conclusions The findings support the acceptability of electronic brief intervention and text messaging for marijuana use during pregnancy. This, combined with their ease of use and low barrier to initiation, suggests that further evaluation in a randomized trial is appropriate. PMID:29117931
Low-Cost Tracking Ground Terminal Designed to Use Cryogenically Cooled Electronics
NASA Technical Reports Server (NTRS)
Wald, Lawrence W.; Romanofsky, Robert R.; Warner, Joseph D.
2000-01-01
A computer-controlled, tracking ground terminal will be assembled at the NASA Glenn Research Center at Lewis Field to receive signals transmitted by the Glenn's Direct Data Distribution (D3) payload planned for a shuttle flight in low Earth orbit. The terminal will enable direct data reception of up to two 622-megabits-per-second (Mbps) beams from the space-based, K-band (19.05-GHz) transmitting array at an end-user bit error rate of up to 10(exp -12). The ground terminal will include a 0.9-m-diameter receive-only Cassegrain reflector antenna with a corrugated feed horn incorporating a dual circularly polarized, K-band feed assembly mounted on a multiaxis, gimbaled tracking pedestal as well as electronics to receive the downlink signals. The tracking system will acquire and automatically track the shuttle through the sky for all elevations greater than 20 above the horizon. The receiving electronics for the ground terminal consist of a six-pole microstrip bandpass filter, a three-stage monolithic microwave integrated circuit (MMIC) amplifier, and a Stirling cycle cryocooler (1 W at 80 K). The Sterling cycle cryocooler cools the front end of the receiver, also known as the low-noise amplifier (LNA), to about 77 K. Cryocooling the LNA significantly increases receiver performance, which is necessary so that it can use the antenna, which has an aperture of only 0.9 m. The following drawing illustrates the cryoterminal.
Applications and advances in electronic-nose technologies
A. D. Wilson; M. Baietto
2009-01-01
Electronic-nose devices have received considerable attention in the field of sensor technology during the past twenty years, largely due to the discovery of numerous applications derived from research in diverse fields of applied sciences. Recent applications of electronic nose technologies have come through advances in sensor design, material improvements, software...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-30
... INTERNATIONAL TRADE COMMISSION [Docket No. 2898] Certain Electronic Imaging Devices; Notice of... Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that the U.S. International Trade Commission has received a complaint entitled Certain Electronic Imaging Devices, DN 2898; the Commission is...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-18
... INTERNATIONAL TRADE COMMISSION [Docket No. 2932] Certain Electronic Bark Control Collars; Notice.... International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that the U.S. International Trade Commission has received a complaint entitled Certain Electronic Bark Control Collars, DN 2932; the...
SpecialNet. A National Computer-Based Communications Network.
ERIC Educational Resources Information Center
Morin, Alfred J.
1986-01-01
"SpecialNet," a computer-based communications network for educators at all administrative levels, has been established and is managed by National Systems Management, Inc. Users can send and receive electronic mail, share information on electronic bulletin boards, participate in electronic conferences, and send reports and other documents to each…
5 CFR 1201.4 - General definitions.
Code of Federal Regulations, 2010 CFR
2010-01-01
... commercial or personal delivery, or by electronic filing (e-filing) in accordance with § 1201.14. (j) Date of... the document was delivered to the commercial delivery service. The date of filing by e-filing is the date of electronic submission. (m) Electronic filing (e-filing). Filing and receiving documents in...
Educators' Perspectives on Having Been Cyber Harassed: A Phenomenological Study
ERIC Educational Resources Information Center
Davenport, Paula M.
2014-01-01
The abuse of individuals through electronic means, typically of students by other students, has been researched extensively. The electronic abuse of other individuals through electronic means has received a dearth of research attention. The purpose of this qualitative transcendental phenomenological study was to explore, describe, and expand the…
High throughput optical scanner
Basiji, David A.; van den Engh, Gerrit J.
2001-01-01
A scanning apparatus is provided to obtain automated, rapid and sensitive scanning of substrate fluorescence, optical density or phosphorescence. The scanner uses a constant path length optical train, which enables the combination of a moving beam for high speed scanning with phase-sensitive detection for noise reduction, comprising a light source, a scanning mirror to receive light from the light source and sweep it across a steering mirror, a steering mirror to receive light from the scanning mirror and reflect it to the substrate, whereby it is swept across the substrate along a scan arc, and a photodetector to receive emitted or scattered light from the substrate, wherein the optical path length from the light source to the photodetector is substantially constant throughout the sweep across the substrate. The optical train can further include a waveguide or mirror to collect emitted or scattered light from the substrate and direct it to the photodetector. For phase-sensitive detection the light source is intensity modulated and the detector is connected to phase-sensitive detection electronics. A scanner using a substrate translator is also provided. For two dimensional imaging the substrate is translated in one dimension while the scanning mirror scans the beam in a second dimension. For a high throughput scanner, stacks of substrates are loaded onto a conveyor belt from a tray feeder.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-17
...DoD is issuing a proposed rule to update Defense Federal Acquisition Regulation Supplement (DFARS), Appendix F, Material Inspection and Receiving Report, to incorporate procedures for using the electronic Wide Area Workflow Receiving Report required for use in most contracts in lieu of the DD Form 250, Material Inspection and Receiving Report, which is now used mostly on an exception basis.
Comparison of RF BPM Receivers for NSLS-II Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pinayev,I.; Singh, O.
2009-05-04
The NSLS-II Light Source being built at Brookhaven National Laboratory requires submicron stability of the electron orbit in the storage ring in order to utilize fully very small emittances and electron beam sizes. This sets high stability requirements for beam position monitors and a program has been initiated for the purpose of characterizing RF beam position monitor (BPM) receivers in use at other light sources. Present state-of-the-art performance will be contrasted with more recently available technologies.
Lesson 5: Overview of CROMERR Requirements for Electronic Reporting
The purpose of the CROMERR requirements is to ensure that authorized programs that receive electronic documents in lieu of paper can rely on those documents for purposes of enforcement-related litigation.
7 CFR 1738.201 - Application submission.
Code of Federal Regulations, 2014 CFR
2014-01-01
... applications must contain two hard copies and an electronic copy of the entire application. An application is considered received upon receipt of the hard and electronic copies by the National Office. The date and time...
7 CFR 1738.201 - Application submission.
Code of Federal Regulations, 2013 CFR
2013-01-01
... applications must contain two hard copies and an electronic copy of the entire application. An application is considered received upon receipt of the hard and electronic copies by the National Office. The date and time...
7 CFR 1738.201 - Application submission.
Code of Federal Regulations, 2012 CFR
2012-01-01
... applications must contain two hard copies and an electronic copy of the entire application. An application is considered received upon receipt of the hard and electronic copies by the National Office. The date and time...
37 CFR 201.38 - Designation of agent to receive notification of claimed infringement.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., including a specific number and street name or rural route, of the agent designated to receive notification... it is the only address that can be used in that geographic location; (5) The telephone number, facsimile number, and electronic mail address of the agent designated to receive notification of claimed...
37 CFR 201.38 - Designation of agent to receive notification of claimed infringement.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., including a specific number and street name or rural route, of the agent designated to receive notification... it is the only address that can be used in that geographic location; (5) The telephone number, facsimile number, and electronic mail address of the agent designated to receive notification of claimed...
37 CFR 201.38 - Designation of agent to receive notification of claimed infringement.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., including a specific number and street name or rural route, of the agent designated to receive notification... it is the only address that can be used in that geographic location; (5) The telephone number, facsimile number, and electronic mail address of the agent designated to receive notification of claimed...
37 CFR 201.38 - Designation of agent to receive notification of claimed infringement.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., including a specific number and street name or rural route, of the agent designated to receive notification... it is the only address that can be used in that geographic location; (5) The telephone number, facsimile number, and electronic mail address of the agent designated to receive notification of claimed...
Pulsed laser illumination of photovoltaic cells
NASA Technical Reports Server (NTRS)
Yater, Jane A.; Lowe, Roland A.; Jenkins, Phillip P.; Landis, Geoffrey A.
1994-01-01
In future space missions, free electron lasers (FEL) may be used to illuminate photovoltaic array receivers to provide remote power. Both the radio-frequency (RF) and induction FEL provide FEL produce pulsed rather than continuous output. In this work we investigate cell response to pulsed laser light which simulates the RF FEL format. The results indicate that if the pulse repetition is high, cell efficiencies are only slightly reduced compared to constant illumination at the same wavelength. The frequency response of the cells is weak, with both voltage and current outputs essentially dc in nature. Comparison with previous experiments indicates that the RF FEL pulse format yields more efficient photovoltaic conversion than does an induction FEL pulse format.
Calibration of optical particle-size analyzer
Pechin, William H.; Thacker, Louis H.; Turner, Lloyd J.
1979-01-01
This invention relates to a system for the calibration of an optical particle-size analyzer of the light-intercepting type for spherical particles, wherein a rotary wheel or disc is provided with radially-extending wires of differing diameters, each wire corresponding to a particular equivalent spherical particle diameter. These wires are passed at an appropriate frequency between the light source and the light detector of the analyzer. The reduction of light as received at the detector is a measure of the size of the wire, and the electronic signal may then be adjusted to provide the desired signal for corresponding spherical particles. This calibrator may be operated at any time without interrupting other processing.
A 10 micron laser heterodyne spectrometer for remote detection of trace gases
NASA Technical Reports Server (NTRS)
Mumma, M. J.; Kostiuk, T.; Buhl, D.
1978-01-01
Infrared heterodyne spectroscopy provides a means of measuring the intensity profiles of individual rotation-vibration spectral lines with high sensitivity. Considerable effort has been expended on optimizing these instruments for remote measurements of gases in planetary atmospheres with the result that present-generation spectrometers are beginning to provide new and startling results on the planets. The fundamental principles of laser heterodyne spectroscopy are discussed. Detailed considerations of the optical design and the electronic design of the spectral-line receiver are given. Representative results obtained with this spectrometer are discussed, including precision frequency measurements of NH3 (nu-2) lines, detection of auroral emission from Jupiter, and measurements of terrestrial O3 and CO2.
NASA Astrophysics Data System (ADS)
Moran, Steven E.; Austin, William L.; Murray, James T.; Roddier, Nicolas A.; Bridges, Robert; Vercillo, Richard; Stettner, Roger; Phillips, Dave; Bisbee, Al; Witherspoon, Ned H.
2003-09-01
Under the Office of Naval Research's Organic Mine Countermeasures Future Naval Capabilities (OMCM FNC) program, Lite Cycles, Inc. is developing an innovative and highly compact airborne active sensor system for mine and obstacle detection in very shallow water (VSW), through the surf-zone (SZ) and onto the beach. The system uses an innovative LCI proprietary integrated scanner, detector, and telescope (ISDT) receiver architecture. The ISD tightly couples all receiver components and LIDAR electronics to achieve the system compaction required for tactical UAVintegration while providing a large aperture. It also includes an advanced compact multifunction laser transmitter; an industry-first high-resolution, compact 3-D camera, a scanning function for wide area search, and temporally displaced multiple looks on the fly over the ocean surface for clutter reduction. Additionally, the laser will provide time-multiplexed multi-color output to perform day/night multispectral imaging for beach surveillance. New processing algorithms for mine detection in the very challenging surf-zone clutter environment are under development, which offer the potential for significant processing gains in comparison to the legacy approaches. This paper reviews the legacy system approaches, describes the mission challenges, and provides an overview of the ROAR system architecture.
Nursing diagnosis: is it time for a new definition?
Herdman, T Heather
2008-01-01
The Diagnosis Development Committee (DDC) of NANDA International frequently receives proposed "physiologic" and "surveillance diagnosis" submissions that may not meet the current definition of nursing diagnosis (NANDA, 2007, p. 332). There has been a request for a vote on newly proposed definitions of nursing diagnosis, risk diagnosis, and syndromes. The purpose of this article is to provide information which enables members and interested nurses to continue the dialogue and to share their thoughts and also to consider the thoughts and information generated by the participants in the NANDA-I interest survey on the definition of nursing diagnoses. An electronic survey of the current NANDA-I definitions, and potential changes to those definitions, was distributed via the NANDA-I Web site. This article summarizes the overall findings of that survey and provides an overview of commentary received from the 269 participants. It is necessary to continue the dialogue on this important decision and to provide a mechanism for input from members and interested nurses before reaching any conclusions on this subject. NANDA-I has been recognized as the leader in the development and implementation of nursing diagnoses and must act responsibly in assessing the changing and emerging trends in nursing practice and in responding to these trends.
Wolf, Michael S.; Kaiser, Darren; Morrow, Daniel G.
2016-01-01
Among patients with various levels of health literacy, the effects of collaborative, patient-provider, medication-planning tools on outcomes relevant to self-management are uncertain. Objective. Among adult patients with type II diabetes mellitus, we tested the effectiveness of a medication-planning tool (Medtable™) implemented via an electronic medical record to improve patients' medication knowledge, adherence, and glycemic control compared to usual care. Design. A multicenter, randomized controlled trial in outpatient primary care clinics. 674 patients received either the Medtable tool or usual care and were followed up for up to 12 months. Results. Patients who received Medtable had greater knowledge about indications for medications in their regimens and were more satisfied with the information about their medications. Patients' knowledge of drug indication improved with Medtable regardless of their literacy status. However, Medtable did not improve patients' demonstrated medication use, regimen adherence, or glycemic control (HbA1c). Conclusion. The Medtable tool supported provider/patient collaboration related to medication use, as reflected in patient satisfaction with communication, but had limited impact on patient medication knowledge, adherence, and HbA1c outcomes. This trial is registered with ClinicalTrials.gov NCT01296633. PMID:27699179
Smith, Ray T.; Jjunju, Fred P. M.; Young, Iain S.; Taylor, Stephen
2016-01-01
A physical model of electromagnetic induction is developed which relates directly the forces between electrons in the transmitter and receiver windings of concentric coaxial finite coils in the near-field region. By applying the principle of superposition, the contributions from accelerating electrons in successive current loops are summed, allowing the peak-induced voltage in the receiver to be accurately predicted. Results show good agreement between theory and experiment for various receivers of different radii up to five times that of the transmitter. The limitations of the linear theory of electromagnetic induction are discussed in terms of the non-uniform current distribution caused by the skin effect. In particular, the explanation in terms of electromagnetic energy and Poynting’s theorem is contrasted with a more direct explanation based on variable filament induction across the conductor cross section. As the direct physical model developed herein deals only with forces between discrete current elements, it can be readily adapted to suit different coil geometries and is widely applicable in various fields of research such as near-field communications, antenna design, wireless power transfer, sensor applications and beyond. PMID:27493580