Taveira-DaSilva, Angelo M; Julien-Williams, Patricia; Jones, Amanda M; Moss, Joel
2016-07-01
Because pneumothorax is frequent in lymphangioleiomyomatosis, patients have expressed concerns regarding the risk of pneumothorax associated with pulmonary function or exercise testing. Indeed, pneumothorax has been reported in patients with lung disease after both of these tests. The aim of this study was to determine the incidence of pneumothorax in patients with lymphangioleiomyomatosis during admissions to the National Institutes of Health Clinical Research Center between 1995 and 2015. Medical records were reviewed to identify patients who had a pneumothorax during their stay at the National Institutes of Health. A total of 691 patients underwent 4,523 pulmonary function tests and 1,900 exercise tests. Three patients developed pneumothorax after pulmonary function tests and/or exercise tests. The incidence of pneumothorax associated with lung function testing was 0.14 to 0.29 of 100 patients or 0.02 to 0.04 of 100 tests. The incidence of pneumothorax in patients undergoing exercise testing was 0.14 to 0.28 of 100 patients or 0.05 to 0.10 of 100 tests. The risk of pneumothorax associated with pulmonary function or exercise testing in patients with lymphangioleiomyomatosis is low. Published by Elsevier Inc.
Aydemir, Koray; Tok, Fatih; Peker, Fatma; Safaz, Ismail; Taskaynatan, Mehmet Ali; Ozgul, Ahmet
2010-01-01
This study aimed to determine the effects of balneotherapy on disease activity, functional status, metrology index, pulmonary function and quality of life in patients with ankylosing spondylitis (AS). The study included 28 patients (27 male and 1 female) diagnosed with AS according to modified New York criteria. The patients were treated with balneotherapy for 3 weeks (30 min/day, 5 days/week). The patients were evaluated using the global index, Bath ankylosing spondylitis disease activity index (BASDAI), disease functional index (BASFI), metrology index (BASMI), chest expansion measures, pulmonary function testing, and the medical outcomes study-short form-36 Health Survey (SF-36) (measure of quality of life) before balneotherapy and 1 month after treatment. Post balneotherapy BASDAI and global index decreased, BASMI parameters improved, chest expansion increased, and some SF-36 parameters improved; however, none of these changes were statistically significant (P > 0.05), except for the decrease in BASMI total score (P < 0.05). Before balneotherapy 6 patients had restrictive pulmonary disorder, according to pulmonary function test results. Pulmonary function test results in 3 (50%) patients were normalized following balneotherapy; however, as for the other index, balneotherapy did not significantly affect pulmonary function test results. The AS patients' symptoms, clinical findings, pulmonary function test results, and quality of life showed a trend to improve following balneotherapy, although without reaching significant differences. Comprehensive randomized controlled spa intervention studies with longer follow-up periods may be helpful in further delineating the therapeutic efficacy of balneotherapy in AS patients.
Noll, Donald R; Johnson, Jane C; Baer, Robert W; Snider, Eric J
2009-01-01
Background The use of manipulation has long been advocated in the treatment of chronic obstructive pulmonary disease (COPD), but few randomized controlled clinical trials have measured the effect of manipulation on pulmonary function. In addition, the effects of individual manipulative techniques on the pulmonary system are poorly understood. Therefore, the purpose of this study was to determine the immediate effects of four osteopathic techniques on pulmonary function measures in persons with COPD relative to a minimal-touch control protocol. Methods Persons with COPD aged 50 and over were recruited for the study. Subjects received five, single-technique treatment sessions: minimal-touch control, thoracic lymphatic pump (TLP) with activation, TLP without activation, rib raising, and myofascial release. There was a 4-week washout period between sessions. Protocols were given in random order until all five techniques had been administered. Pulmonary function measures were obtained at baseline and 30-minutes posttreatment. For the actual pulmonary function measures and percent predicted values, Wilcoxon signed rank tests were used to test within-technique changes from baseline. For the percent change from baseline, Friedman tests were used to test for between-technique differences. Results Twenty-five subjects were enrolled in the study. All four tested osteopathic techniques were associated with adverse posttreatment changes in pulmonary function measures; however, different techniques changed different measures. TLP with activation increased posttreatment residual volume compared to baseline, while TLP without activation did not. Side effects were mild, mostly posttreatment chest wall soreness. Surprisingly, the majority of subjects believed they could breathe better after receiving osteopathic manipulation. Conclusion In persons with COPD, TLP with activation, TLP without activation, rib raising, and myofascial release mildly worsened pulmonary function measures immediately posttreatment relative to baseline measurements. The activation component of the TLP technique appears to increase posttreatment residual volume. Despite adverse changes in pulmonary function measures, persons with COPD subjectively reported they benefited from osteopathic manipulation. PMID:19814829
Noll, Donald R; Johnson, Jane C; Baer, Robert W; Snider, Eric J
2009-10-08
The use of manipulation has long been advocated in the treatment of chronic obstructive pulmonary disease (COPD), but few randomized controlled clinical trials have measured the effect of manipulation on pulmonary function. In addition, the effects of individual manipulative techniques on the pulmonary system are poorly understood. Therefore, the purpose of this study was to determine the immediate effects of four osteopathic techniques on pulmonary function measures in persons with COPD relative to a minimal-touch control protocol. Persons with COPD aged 50 and over were recruited for the study. Subjects received five, single-technique treatment sessions: minimal-touch control, thoracic lymphatic pump (TLP) with activation, TLP without activation, rib raising, and myofascial release. There was a 4-week washout period between sessions. Protocols were given in random order until all five techniques had been administered. Pulmonary function measures were obtained at baseline and 30-minutes posttreatment. For the actual pulmonary function measures and percent predicted values, Wilcoxon signed rank tests were used to test within-technique changes from baseline. For the percent change from baseline, Friedman tests were used to test for between-technique differences. Twenty-five subjects were enrolled in the study. All four tested osteopathic techniques were associated with adverse posttreatment changes in pulmonary function measures; however, different techniques changed different measures. TLP with activation increased posttreatment residual volume compared to baseline, while TLP without activation did not. Side effects were mild, mostly posttreatment chest wall soreness. Surprisingly, the majority of subjects believed they could breathe better after receiving osteopathic manipulation. In persons with COPD, TLP with activation, TLP without activation, rib raising, and myofascial release mildly worsened pulmonary function measures immediately posttreatment relative to baseline measurements. The activation component of the TLP technique appears to increase posttreatment residual volume. Despite adverse changes in pulmonary function measures, persons with COPD subjectively reported they benefited from osteopathic manipulation.
Liu, Jia-Ming; Shen, Jian-Xiong; Zhang, Jian-Guo; Zhao, Hong; Li, Shu-Gang; Zhao, Yu; Qiu, Giu-Xing
2012-01-01
It has been stated that preoperative pulmonary function tests are essential to assess the surgical risk in patients with scoliosis. Arterial blood gas tests have also been used to evaluate pulmonary function before scoliotic surgery. However, few studies have been reported. The aim of this study was to investigate the roles of preoperative arterial blood gas tests in the surgical treatment of scoliosis with moderate or severe pulmonary dysfunction. This study involved scoliotic patients with moderate or severe pulmonary dysfunction (forced vital capacity < 60%) who underwent surgical treatment between January 2002 and April 2010. A total of 73 scoliotic patients (23 males and 50 females) with moderate or severe pulmonary dysfunction were included. The average age of the patients was 16.53 years (ranged 10 - 44). The demographic distribution, medical records, and radiographs of all patients were collected. All patients received arterial blood gas tests and pulmonary function tests before surgery. The arterial blood gas tests included five parameters: partial pressure of arterial oxygen, partial pressure of arterial carbon dioxide, alveolar-arterial oxygen tension gradient, pH, and standard bases excess. The pulmonary function tests included three parameters: forced expiratory volume in 1 second ratio, forced vital capacity ratio, and peak expiratory flow ratio. All five parameters of the arterial blood gas tests were compared between the two groups with or without postoperative pulmonary complications by variance analysis. Similarly, all three parameters of the pulmonary function tests were compared. The average coronal Cobb angle before surgery was 97.42° (range, 50° - 180°). A total of 15 (20.5%) patients had postoperative pulmonary complications, including hypoxemia in 5 cases (33.3%), increased requirement for postoperative ventilatory support in 4 (26.7%), pneumonia in 2 (13.3%), atelectasis in 2 (13.3%), pneumothorax in 1 (6.7%), and hydrothorax in 1 (6.7%). No significant differences in demographic characteristics or perioperative factors (P > 0.05) existed between the two groups with or without postoperative pulmonary complications. According to the variance analysis, there were no statistically significant differences in any parameter of the arterial blood gas tests between the two groups. No significant correlation between the results of the preoperative arterial blood gas tests and postoperative pulmonary complications existed in scoliotic patients with moderate or severe pulmonary dysfunction. However, the postoperative complications tended to increase with the decrease of partial pressure of arterial oxygen in the arterial blood gas tests.
Pulmonary function and the risk of functional limitation in chronic obstructive pulmonary disease.
Eisner, Mark D; Iribarren, Carlos; Yelin, Edward H; Sidney, Stephen; Katz, Patricia P; Ackerson, Lynn; Lathon, Phenius; Tolstykh, Irina; Omachi, Theodore; Byl, Nancy; Blanc, Paul D
2008-05-01
The authors' objective was to analyze the impact of respiratory impairment on the risk of physical functional limitations among adults with chronic obstructive pulmonary disease (COPD). They hypothesized that greater pulmonary function decrement would result in a broad array of physical functional limitations involving organ systems remote from the lung, a key step in the pathway leading to overall disability. The authors used baseline data from the Function, Living, Outcomes, and Work (FLOW) study, a prospective cohort study of adults with COPD recruited from northern California in 2005-2007. They studied the impact of pulmonary function impairment on the risk of functional limitations using validated measures: lower extremity function (Short Physical Performance Battery), submaximal exercise performance (6-Minute Walk Test), standing balance (Functional Reach Test), skeletal muscle strength (manual muscle testing with dynamometry), and self-reported functional limitation (standardized item battery). Multiple variable analysis was used to control for confounding by age, sex, race, height, educational attainment, and cigarette smoking. Greater pulmonary function impairment, as evidenced by lower forced expiratory volume in 1 second (FEV(1)), was associated with poorer Short Physical Performance Battery scores and less distance walked during the 6-Minute Walk Test. Lower forced expiratory volume in 1 second was also associated with weaker muscle strength and with a greater risk of self-reported functional limitation (p < 0.05). In conclusion, pulmonary function impairment is associated with multiple manifestations of physical functional limitation among COPD patients. Longitudinal follow-up can delineate the impact of these functional limitations on the prospective risk of disability, guiding preventive strategies that could attenuate the disablement process.
Olfert, S M; Pahwa, P; Dosman, J A
2005-11-01
The negative health effects of exposure to grain dust have previously been examined, but few studies have observed the effects on newly hired employees. Young grain workers are of interest because changes in pulmonary function may occur after a short duration of employment, and because older grain workers may represent a survivor population. The New Grain Workers Study (NGWS), a longitudinal study of 299 newly hired male grain industry workers, was conducted between 1980 and 1985. The objectives were to determine the effects of employment in the grain industry on pulmonary function. Pre-employment physical examinations and pulmonary function tests were conducted on subjects at the Division of Respiratory Medicine, Department of Medicine, Royal University Hospital, University of Saskatchewan. The Grain Dust Medical Surveillance Program (GDMSP) was a Labour Canada program that began in 1978. All subjects were grain workers employed in the grain industry in Saskatchewan. All subjects completed a respiratory symptoms questionnaire and underwent pulmonary function testing. Baseline observations were recorded every three years between 1978 and 1993. Data were available on 2184 grain workers. Generalized estimating equations were used to fit marginal and transitional multivariable regression models to determine the effects of grain dust exposure on pulmonary function. Marginal and transitional models were then compared. Height, exposure weeks, and previous FVC were predictive of FVC in the NGWS, while exposure weeks and previous FEV1 were predictive of FEV1. These models, as well as a transitional regression model built using the GDMSP data, were used to compute predicted mean annual decline inpulmonary function. Non-smoking grain workers in the NGWS had the highest pulmonary function test values, but also had the greatest predicted annual decline in pulmonary function. Ever-smoking grain workers in the GDMSP had the lowest pulmonary function test values. Non-smoking grain workers in the GDMSP had the least predicted annual decline in pulmonary function.
Pulmonary Morbidity in Infancy after Exposure to Chorioamnionitis in Late Preterm Infants.
McDowell, Karen M; Jobe, Alan H; Fenchel, Matthew; Hardie, William D; Gisslen, Tate; Young, Lisa R; Chougnet, Claire A; Davis, Stephanie D; Kallapur, Suhas G
2016-06-01
Chorioamnionitis is an important cause of preterm birth, but its impact on postnatal outcomes is understudied. To evaluate whether fetal exposure to inflammation is associated with adverse pulmonary outcomes at 6 to 12 months' chronological age in infants born moderate to late preterm. Infants born between 32 and 36 weeks' gestational age were prospectively recruited (N = 184). Chorioamnionitis was diagnosed by placenta and umbilical cord histology. Select cytokines were measured in samples of cord blood. Validated pulmonary questionnaires were administered (n = 184), and infant pulmonary function testing was performed (n = 69) between 6 and 12 months' chronological age by the raised volume rapid thoracoabdominal compression technique. A total of 25% of participants had chorioamnionitis. Although infant pulmonary function testing variables were lower in infants born preterm compared with historical normative data for term infants, there were no differences between infants with chorioamnionitis (n = 20) and those without (n = 49). Boys and black infants had lower infant pulmonary function testing measurements than girls and white infants, respectively. Chorioamnionitis exposure was associated independently with wheeze (odds ratio [OR], 2.08) and respiratory-related physician visits (OR, 3.18) in the first year of life. Infants exposed to severe chorioamnionitis had increased levels of cord blood IL-6 and greater pulmonary morbidity at age 6 to 12 months than those exposed to mild chorioamnionitis. Elevated IL-6 was associated with significantly more respiratory problems (OR, 3.23). In infants born moderate or late preterm, elevated cord blood IL-6 and exposure to histologically identified chorioamnionitis was associated with respiratory morbidity during infancy without significant changes in infant pulmonary function testing measurements. Black compared with white and boy compared with girl infants had lower infant pulmonary function testing measurements and worse pulmonary outcomes.
Pulmonary function tests correlated with thoracic volumes in adolescent idiopathic scoliosis.
Ledonio, Charles Gerald T; Rosenstein, Benjamin E; Johnston, Charles E; Regelmann, Warren E; Nuckley, David J; Polly, David W
2017-01-01
Scoliosis deformity has been linked with deleterious changes in the thoracic cavity that affect pulmonary function. The causal relationship between spinal deformity and pulmonary function has yet to be fully defined. It has been hypothesized that deformity correction improves pulmonary function by restoring both respiratory muscle efficiency and increasing the space available to the lungs. This research aims to correlate pulmonary function and thoracic volume before and after scoliosis correction. Retrospective correlational analysis between thoracic volume modeling from plain x-rays and pulmonary function tests was conducted. Adolescent idiopathic scoliosis patients enrolled in a multicenter database were sorted by pre-operative Total Lung Capacities (TLC) % predicted values from their Pulmonary Function Tests (PFT). Ten patients with the best and ten patients with the worst TLC values were included. Modeled thoracic volume and TLC values were compared before and 2 years after surgery. Scoliosis correction resulted in an increase in the thoracic volume for patients with the worst initial TLCs (11.7%) and those with the best initial TLCs (12.5%). The adolescents with the most severe pulmonary restriction prior to surgery strongly correlated with post-operative change in total lung capacity and thoracic volume (r 2 = 0.839; p < 0.001). The mean increase in thoracic volume in this group was 373.1 cm 3 (11.7%) which correlated with a 21.2% improvement in TLC. Scoliosis correction in adolescents was found to increase thoracic volume and is strongly correlated with improved TLC in cases with severe restrictive pulmonary function, but no correlation was found in cases with normal pulmonary function. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:175-182, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Culver, Bruce H; Graham, Brian L; Coates, Allan L; Wanger, Jack; Berry, Cristine E; Clarke, Patricia K; Hallstrand, Teal S; Hankinson, John L; Kaminsky, David A; MacIntyre, Neil R; McCormack, Meredith C; Rosenfeld, Margaret; Stanojevic, Sanja; Weiner, Daniel J
2017-12-01
The American Thoracic Society committee on Proficiency Standards for Pulmonary Function Laboratories has recognized the need for a standardized reporting format for pulmonary function tests. Although prior documents have offered guidance on the reporting of test data, there is considerable variability in how these results are presented to end users, leading to potential confusion and miscommunication. A project task force, consisting of the committee as a whole, was approved to develop a new Technical Standard on reporting pulmonary function test results. Three working groups addressed the presentation format, the reference data supporting interpretation of results, and a system for grading quality of test efforts. Each group reviewed relevant literature and wrote drafts that were merged into the final document. This document presents a reporting format in test-specific units for spirometry, lung volumes, and diffusing capacity that can be assembled into a report appropriate for a laboratory's practice. Recommended reference sources are updated with data for spirometry and diffusing capacity published since prior documents. A grading system is presented to encourage uniformity in the important function of test quality assessment. The committee believes that wide adoption of these formats and their underlying principles by equipment manufacturers and pulmonary function laboratories can improve the interpretation, communication, and understanding of test results.
21 CFR 868.1880 - Pulmonary-function data calculator.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pulmonary-function data calculator. 868.1880 Section 868.1880 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...-function values based on actual physical data obtained during pulmonary-function testing. (b...
21 CFR 868.1880 - Pulmonary-function data calculator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pulmonary-function data calculator. 868.1880 Section 868.1880 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...-function values based on actual physical data obtained during pulmonary-function testing. (b...
The Relationship of Welding Fume Exposure, Smoking, and Pulmonary Function in Welders.
Roach, Laura L
2018-01-01
The purpose of this study was to explore the relationship between occupational exposure to welding fumes and pulmonary function in an effort to add supportive evidence and clarity to the current body of research. This study utilized a retrospective chart review of pulmonary function testing and pulmonary questionnaires already available in charts from preplacement physicals to the most recent test. When comparing smokers to nonsmokers, utilizing multiple regression and controlling for age and percentage of time using a respirator, years welding was statistically significant at p = .04. Data support that smoking has a synergistic effect when combined with welding fume exposure on pulmonary decline.
Pulmonary functions in patients with subclinical hypothyroidism.
Cakmak, Gulfidan; Saler, Tayyibe; Saglam, Zuhal Aydan; Yenigun, Mustafa; Ataoglu, Esra; Demir, Tuncalp; Temiz, Levent Umit
2011-10-01
To determine whether alterations in pulmonary function takes place in subclinical hypothyroidism by examining the diffusion lung capacity and muscle strength of such patients. This is a descriptive study conducted in 2009 at Haseki Training and Research Hospital, Istanbul, Turkey. Hundred and twenty-six patients with subclinical hypothyroidism and 58 age and sex matched individuals were recruited. Simple spirometry tests were performed, and pulmonary diffusion capacity (DLco) and muscle strength were measured. ScH patients showed a significant reduciton of the following pulmonary function tests (% predicted value) as compared with control subjects: FVC, FEV1, FEV1%, FEF25-75, FEF25-75%, DLco, DLco/VA, Pimax, Pimax% and Pemax%. These data indicate that pulmonary functions are effected in subclinical hypothyrodism. Therefore patients with or who are at high risk of having subclinical hypothyroidism, should be subjected to evaluation of pulmonary functions with simple spirometry.
IDENTIFICATION AND CHARACTERIZATION OF DISEASE USING PULMONARY FUNCTION TESTS
Abstract
Pulmonary function testing is used routinely in human medicine to objectively define functional deficits in individuals with respiratory disease. Despite the fact that respiratory disease is a common problem in veterinary medicine, evaluation of the small animal pa...
Yabuuchi, Hidetake; Kawanami, Satoshi; Kamitani, Takeshi; Yonezawa, Masato; Yamasaki, Yuzo; Yamanouchi, Torahiko; Nagao, Michinobu; Okamoto, Tatsuro; Honda, Hiroshi
2016-11-01
To compare the predictabilities of postoperative pulmonary function after lobectomy for primary lung cancer among counting method, effective lobar volume, and lobar collapsibility. Forty-nine patients who underwent lobectomy for primary lung cancer were enrolled. All patients underwent inspiratory/expiratory CT and pulmonary function tests 2 weeks before surgery and postoperative pulmonary function tests 6-7 months after surgery. Pulmonary function losses (ΔFEV 1.0 and ΔVC) were calculated from the pulmonary function tests. Predictive postoperative pulmonary function losses (ppoΔFEV 1.0 and ppoΔVC) were calculated using counting method, effective volume, and lobar collapsibility. Correlations and agreements between ΔFEV 1.0 and ppoFEV 1.0 and those between ΔVC and ppoΔVC were tested among three methods using Spearman's correlation coefficient and Bland-Altman plots. ΔFEV 1.0 and ppoΔFEV 1.0insp-exp were strongly correlated (r=0.72), whereas ΔFEV 1.0 and ppoΔFEV 1.0count and ΔFEV 1.0 and Pred. ΔFEV 1.0eff.vol. were moderately correlated (r=0.50, 0.56). ΔVC and ppoΔVC eff.vol. (r=0.71) were strongly correlated, whereas ΔVC and ppoΔVC count , and ΔVC and ppoΔVC insp-exp were moderately correlated (r=0.55, 0.42). Volumetry from inspiratory/expiratory CT data could be useful to predict postoperative pulmonary function after lobectomy for primary lung cancer. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Advanced Techniques in Pulmonary Function Test Analysis Interpretation and Diagnosis
Gildea, T.J.; Bell, C. William
1980-01-01
The Pulmonary Functions Analysis and Diagnostic System is an advanced clinical processing system developed for use at the Pulmonary Division, Department of Medicine at the University of Nebraska Medical Center. The system generates comparative results and diagnostic impressions for a variety of routine and specialized pulmonary functions test data. Routine evaluation deals with static lung volumes, breathing mechanics, diffusing capacity, and blood gases while specialized tests include lung compliance studies, small airways dysfunction studies and dead space to tidal volume ratios. Output includes tabular results of normal vs. observed values, clinical impressions and commentary and, where indicated, a diagnostic impression. A number of pulmonary physiological and state variables are entered or sampled (A to D) with periodic status reports generated for the test supervisor. Among the various physiological variables sampled are respiratory frequency, minute ventilation, oxygen consumption, carbon dioxide production, and arterial oxygen saturation.
Impaired pulmonary function after treatment for tuberculosis: the end of the disease?
Chushkin, Mikhail Ivanovich; Ots, Oleg Nikolayevich
2017-01-01
ABSTRACT Objective: To evaluate the prevalence of pulmonary function abnormalities and to investigate the factors affecting lung function in patients treated for pulmonary tuberculosis. Methods: A total of 214 consecutive patients (132 men and 82 women; 20-82 years of age), treated for pulmonary tuberculosis and followed at a local dispensary, underwent spirometry and plethysmography at least one year after treatment. Results: Pulmonary impairment was present in 102 (47.7%) of the 214 patients evaluated. The most common functional alteration was obstructive lung disease (seen in 34.6%). Of the 214 patients, 60 (28.0%) showed reduced pulmonary function (FEV1 below the lower limit of normal). Risk factors for reduced pulmonary function were having had culture-positive pulmonary tuberculosis in the past, being over 50 years of age, having recurrent tuberculosis, and having a lower level of education. Conclusions: Nearly half of all tuberculosis patients evolve to impaired pulmonary function. That underscores the need for pulmonary function testing after the end of treatment. PMID:28380187
INTERPRETATIONS AND LIMITATION OF PULMONARY FUNCTION TESTING IN SMALL LABORATORY ANIMALS
Pulmonary function tests are tools available to the researcher and clinician to evaluate the ability of the lung to perform its essential function of gas exchange. o meet this principal function, the lung needs to operate efficiently with minimal mechanical work as well as provid...
Pulmonary function and respiratory symptoms in potash workers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Graham, B.L.; Dosman, J.A.; Cotton, D.J.
1984-03-01
Over 94% of the workers in each of four Saskatchewan potash mines participated in a respiratory health surveillance program that included a questionnaire and pulmonary function tests. Compared with a nonexposed control group, potash workers had higher prevalences of cough, dyspnea, and chronic bronchitis but better pulmonary function. Prevalences of symptoms and pulmonary function abnormalities were similar among workers at the four mines tested and at the various job locations. Potash dust, diesel fumes, and other air contaminants may have an irritant effect that leads to the increased prevalences of cough and chronic bronchitis. Although no adverse effects of themore » potash mine environment on pulmonary function were found, these findings reflect a healthy worker effect or some selection process that makes the potash workers appear healthier in a cross-sectional study.« less
Pulmonary function and respiratory symptoms in potash workers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Graham, B.L.; Dosman, J.A.; Cotton, D.J.
1984-03-01
Over 94% of the workers in each of four Saskatchewan potash mines participated in a respiratory health surveillance program that included a questionnaire and pulmonary function tests. Compared with a nonexposed control group, potash workers had higher prevalences of cough, dyspnea, and chronic bronchitis but better pulmonary function. Prevalences of symptoms and pulmonary function abnormalities were similar among workers at the four mines tested and at the various job locations. Potash dust, diesel fumes, and other air contaminants may have an irritant effect that leads to the increased prevalences of cough and chronic bronchitis. Although we found no adverse effectsmore » of the potash mine environment on pulmonary function, these findings reflect a healthy worker effect or some selection process that makes the potash workers appear healthier in a cross-sectional study.« less
Obstructive lung disease as a complication in post pulmonary TB
NASA Astrophysics Data System (ADS)
Tarigan, A. P.; Pandia, P.; Eyanoer, P.; Tina, D.; Pratama, R.; Fresia, A.; Tamara; Silvanna
2018-03-01
The case of post TB is a problem that arises in the community. Pulmonary tuberculosis (TB) can affect lung function. Therefore, we evaluated impaired pulmonary function in subjects with diagnosed prior pulmonary TB. A Case Series study, pulmonary function test was performed in subjects with a history of pulmonary tuberculosis; aged ≥18 years were included. Exclusion criteria was a subject who had asthma, obesity, abnormal thorax and smoking history. We measured FEV1 and FVC to evaluate pulmonary function. Airflow obstruction was FEV1/FVC%<75 and restriction was FVC<80% according to Indonesia’s pneumomobile project. This study was obtained from 23 patients with post pulmonary TB, 5 subjects (23%) had airflow obstruction with FEV1/FVC% value <75%, 15 subjects (71.4%) had abnormalities restriction with FVC value <80% and 3 subjects (5.6%) had normal lung function. Obstructive lung disease is one of the complications of impaired lung function in post pulmonary TB.
Kumar, Amaravadi Sampath; Alaparthi, Gopala Krishna; Augustine, Alfred Joseph; Pazhyaottayil, Zulfeequer Chundaanveetil; Ramakrishna, Anand; Krishnakumar, Shyam Krishnan
2016-01-01
Surgical procedures in abdominal area lead to changes in pulmonary function, respiratory mechanics and impaired physical capacity leading to postoperative pulmonary complications, which can affect up to 80% of upper abdominal surgery. To evaluate the effects of flow and volume incentive spirometry on pulmonary function and exercise tolerance in patients undergoing open abdominal surgery. A randomized clinical trial was conducted in a hospital of Mangalore city in Southern India. Thirty-seven males and thirteen females who were undergoing abdominal surgeries were included and allocated into flow and volume incentive spirometry groups by block randomization. All subjects underwent evaluations of pulmonary function with measurement of Forced Vital Capacity (FVC), Forced Expiratory Volume in the first second (FEV1), Peak Expiratory Flow (PEF). Preoperative and postoperative measurements were taken up to day 5 for both groups. Exercise tolerance measured by Six- Minute Walk Test during preoperative period and measured again at the time of discharge for both groups. Pulmonary function was analysed by post-hoc analysis and carried out using Bonferroni's 't'-test. Exercise tolerance was analysed by Paired 'T'-test. Pulmonary function (FVC, FEV1, and PEFR) was found to be significantly decreased in 1(st), 2(nd) and 3(rd) postoperative day when compared with preoperative day. On 4(th) and 5(th) postoperative day the pulmonary function (FVC, FEV1, and PEFR) was found to be better preserved in both flow and volume incentive spirometry groups. The Six-Minute Walk Test showed a statistically significant improvement in pulmonary function on the day of discharge than in the preoperative period. In terms of distance covered, the volume- incentive spirometry group showed a greater statistically significant improvement from the preoperative period to the time of discharge than was exhibited by the flow incentive spirometry group. Flow and volume incentive spirometry can be safely recommended to patients undergoing open abdominal surgery as there have been no adverse events recorded. Also, these led to a demonstrable improvement in pulmonary function and exercise tolerance.
Kumar, Amaravadi Sampath; Augustine, Alfred Joseph; Pazhyaottayil, Zulfeequer Chundaanveetil; Ramakrishna, Anand; Krishnakumar, Shyam Krishnan
2016-01-01
Introduction Surgical procedures in abdominal area lead to changes in pulmonary function, respiratory mechanics and impaired physical capacity leading to postoperative pulmonary complications, which can affect up to 80% of upper abdominal surgery. Aim To evaluate the effects of flow and volume incentive spirometry on pulmonary function and exercise tolerance in patients undergoing open abdominal surgery. Materials and Methods A randomized clinical trial was conducted in a hospital of Mangalore city in Southern India. Thirty-seven males and thirteen females who were undergoing abdominal surgeries were included and allocated into flow and volume incentive spirometry groups by block randomization. All subjects underwent evaluations of pulmonary function with measurement of Forced Vital Capacity (FVC), Forced Expiratory Volume in the first second (FEV1), Peak Expiratory Flow (PEF). Preoperative and postoperative measurements were taken up to day 5 for both groups. Exercise tolerance measured by Six- Minute Walk Test during preoperative period and measured again at the time of discharge for both groups. Pulmonary function was analysed by post-hoc analysis and carried out using Bonferroni’s ‘t’-test. Exercise tolerance was analysed by Paired ‘T’-test. Results Pulmonary function (FVC, FEV1, and PEFR) was found to be significantly decreased in 1st, 2nd and 3rd postoperative day when compared with preoperative day. On 4th and 5th postoperative day the pulmonary function (FVC, FEV1, and PEFR) was found to be better preserved in both flow and volume incentive spirometry groups. The Six-Minute Walk Test showed a statistically significant improvement in pulmonary function on the day of discharge than in the preoperative period. In terms of distance covered, the volume- incentive spirometry group showed a greater statistically significant improvement from the preoperative period to the time of discharge than was exhibited by the flow incentive spirometry group. Conclusion Flow and volume incentive spirometry can be safely recommended to patients undergoing open abdominal surgery as there have been no adverse events recorded. Also, these led to a demonstrable improvement in pulmonary function and exercise tolerance. PMID:26894090
Pulmonary Morbidity in Infancy after Exposure to Chorioamnionitis in Late Preterm Infants
McDowell, Karen M.; Jobe, Alan H.; Fenchel, Matthew; Hardie, William D.; Gisslen, Tate; Young, Lisa R.; Chougnet, Claire A.; Davis, Stephanie D.
2016-01-01
Rationale: Chorioamnionitis is an important cause of preterm birth, but its impact on postnatal outcomes is understudied. Objectives: To evaluate whether fetal exposure to inflammation is associated with adverse pulmonary outcomes at 6 to 12 months’ chronological age in infants born moderate to late preterm. Methods: Infants born between 32 and 36 weeks’ gestational age were prospectively recruited (N = 184). Chorioamnionitis was diagnosed by placenta and umbilical cord histology. Select cytokines were measured in samples of cord blood. Validated pulmonary questionnaires were administered (n = 184), and infant pulmonary function testing was performed (n = 69) between 6 and 12 months’ chronological age by the raised volume rapid thoracoabdominal compression technique. Measurements and Main Results: A total of 25% of participants had chorioamnionitis. Although infant pulmonary function testing variables were lower in infants born preterm compared with historical normative data for term infants, there were no differences between infants with chorioamnionitis (n = 20) and those without (n = 49). Boys and black infants had lower infant pulmonary function testing measurements than girls and white infants, respectively. Chorioamnionitis exposure was associated independently with wheeze (odds ratio [OR], 2.08) and respiratory-related physician visits (OR, 3.18) in the first year of life. Infants exposed to severe chorioamnionitis had increased levels of cord blood IL-6 and greater pulmonary morbidity at age 6 to 12 months than those exposed to mild chorioamnionitis. Elevated IL-6 was associated with significantly more respiratory problems (OR, 3.23). Conclusions: In infants born moderate or late preterm, elevated cord blood IL-6 and exposure to histologically identified chorioamnionitis was associated with respiratory morbidity during infancy without significant changes in infant pulmonary function testing measurements. Black compared with white and boy compared with girl infants had lower infant pulmonary function testing measurements and worse pulmonary outcomes. PMID:27015030
Ergün, Recai; Evcik, Ender; Ergün, Dilek; Ergan, Begüm; Özkan, Esin; Gündüz, Özge
2017-05-05
The number of studies where non-malignant pulmonary diseases are evaluated after occupational arsenic exposure is very few. To investigate the effects of occupational arsenic exposure on the lung by high-resolution computed tomography and pulmonary function tests. Retrospective cross-sectional study. In this study, 256 workers with suspected respiratory occupational arsenic exposure were included, with an average age of 32.9±7.8 years and an average of 3.5±2.7 working years. Hair and urinary arsenic levels were analysed. High-resolution computed tomography and pulmonary function tests were done. In workers with occupational arsenic exposure, high-resolution computed tomography showed 18.8% pulmonary involvement. In pulmonary involvement, pulmonary nodule was the most frequently seen lesion (64.5%). The other findings of pulmonary involvement were 18.8% diffuse interstitial lung disease, 12.5% bronchiectasis, and 27.1% bullae-emphysema. The mean age of patients with pulmonary involvement was higher and as they smoked more. The pulmonary involvement was 5.2 times higher in patients with skin lesions because of arsenic. Diffusing capacity of lung for carbon monoxide was significantly lower in patients with pulmonary involvement. Besides lung cancer, chronic occupational inhalation of arsenic exposure may cause non-malignant pulmonary findings such as bronchiectasis, pulmonary nodules and diffuse interstitial lung disease. So, in order to detect pulmonary involvement in the early stages, workers who experience occupational arsenic exposure should be followed by diffusion test and high-resolution computed tomography.
Using Operational Analysis to Improve Access to Pulmonary Function Testing.
Ip, Ada; Asamoah-Barnieh, Raymond; Bischak, Diane P; Davidson, Warren J; Flemons, W Ward; Pendharkar, Sachin R
2016-01-01
Background. Timely pulmonary function testing is crucial to improving diagnosis and treatment of pulmonary diseases. Perceptions of poor access at an academic pulmonary function laboratory prompted analysis of system demand and capacity to identify factors contributing to poor access. Methods. Surveys and interviews identified stakeholder perspectives on operational processes and access challenges. Retrospective data on testing demand and resource capacity was analyzed to understand utilization of testing resources. Results. Qualitative analysis demonstrated that stakeholder groups had discrepant views on access and capacity in the laboratory. Mean daily resource utilization was 0.64 (SD 0.15), with monthly average utilization consistently less than 0.75. Reserved testing slots for subspecialty clinics were poorly utilized, leaving many testing slots unfilled. When subspecialty demand exceeded number of reserved slots, there was sufficient capacity in the pulmonary function schedule to accommodate added demand. Findings were shared with stakeholders and influenced scheduling process improvements. Conclusion. This study highlights the importance of operational data to identify causes of poor access, guide system decision-making, and determine effects of improvement initiatives in a variety of healthcare settings. Importantly, simple operational analysis can help to improve efficiency of health systems with little or no added financial investment.
Pulmonary Function in Children with Development Coordination Disorder
ERIC Educational Resources Information Center
Wu, Sheng K.; Cairney, John; Lin, Hsiao-Hui; Li, Yao-Chuen; Song, Tai-Fen
2011-01-01
The purpose of this study was to compare pulmonary function in children with developmental coordination disorder (DCD) with children who are typically developing (TD), and also analyze possible gender differences in pulmonary function between these groups. The Movement ABC test was used to identify the movement coordination ability of children.…
Pérez Aceves, Eva; Pérez Cristóbal, Mario; Espinola Reyna, Gerardo A; Ariza Andraca, Raul; Xibille Fridmann, Daniel; Barile Fabris, Leonor A
2013-01-01
Pulmonary hemorrhage (PH) occurs in 2-5% of SLE patients, and is associated with a high mortality rate (79-90%). Diagnostic criteria for this complication include: 1) Pulmonary infiltrates, with at least ¾ of lung tissue involved in a chest x ray, 2) Acute respiratory failure, 3) A decrease of 3g/dL or more in hemoglobin levels. PH might lead to organized pneumonia, collagen deposition, and pulmonary fibrosis which in time might cause changes in pulmonary function tests with either restrictive or obstructive patterns. To evaluate the existence of abnormalities in pulmonary function tests after a PH episode. We included patients with SLE and primary vasculitis that developed PH. During the acute episode, we measured SLEDAI in SLE patients, five factor score in microscopic polyangiitis (MPA) and Birmingham Vasculitis Activity Store (BVAS) in granulomatosis with polyangiitis (GPA) (Wegener). We determined the number of PH events, treatment, and ventilator assistance requirements and correlated its association with abnormal pulmonary function tests. We included 10 patients, 7 with SLE, 2 with MPA and 1 with GPA (Wegener). The mean activity measures were: SLEDAI 20.4 ± 7.5, FFS 2, and BVAS 36. Treatment consisted in methylprednisolone (MPD) in 3 patients, MPD plus cyclophosphamide (CY) in 6 patients, and MPD, CY, IV immunoglobulin, and plasmapheresis in one patient. Five patients required ventilatory support. We found abnormalities in pulmonary function tests in 8 patients, three had an obstructive pattern and five a restrictive pattern; 2 patients did not show any change. We did not find a significant association with any of the studied variables. PH might cause abnormalities in pulmonary function tests and prolonged immunosuppressive treatment could be required. Copyright © 2012 Elsevier España, S.L. All rights reserved.
Effect of Exercise on Pulmonary Function Tests in Obese Malaysian Patients.
Christopher, L K S; Kosai, N R; Reynu, R; Levin, K B; Taher, M M; Sutton, P A; Sukor, N; Das, S
2015-01-01
Obesity has taken the 21st century by storm, posing negative effects on of the various facades of health, healthcare and global economy. With regards to pulmonary performance, numerous studies have proven the detrimental effects of obesity while reinstating the positive effects of weight loss on overall pulmonary function. However, effects of exercise on pulmonary function and correlation between changes in pulmonary function test with weight loss have yet to be described. We performed a prospective interventional study to determine the effects of regular exercise on Pulmonary Function Tests (PFT) and ascertain the relationship between weight loss and change in PFT in obese patients. Twenty-five obese patients were enrolled, giving an 80% power of study. Baseline weight and PFT consisting of FEV1, FVC, TLC, mean ERV and VC were recorded prior to commencement of the 8 week long Standard Exercise Regimen (SER). PFT and weight were recorded again at the end of 8 weeks. All parameters of the PFT studied improved significantly with exercise. The participants lost an average of 1kg of body weight post-exercise (p<0.0005). The correlations between mean changes in weight and PFT were negligible. A period of supervised regular exercise improves the pulmonary function of obese patients and this improvement is independent of the amount of weight loss. Hence, SER should be recommended to all obese patients, especially when bariatric surgery is desired.
Kobayashi, Keisuke; Saeki, Yusuke; Kitazawa, Shinsuke; Kobayashi, Naohiro; Kikuchi, Shinji; Goto, Yukinobu; Sakai, Mitsuaki; Sato, Yukio
2017-11-01
It is important to accurately predict the patient's postoperative pulmonary function. The aim of this study was to compare the accuracy of predictions of the postoperative residual pulmonary function obtained with three-dimensional computed tomographic (3D-CT) volumetry with that of predictions obtained with the conventional segment-counting method. Fifty-three patients scheduled to undergo lung cancer resection, pulmonary function tests, and computed tomography were enrolled in this study. The postoperative residual pulmonary function was predicted based on the segment-counting and 3D-CT volumetry methods. The predicted postoperative values were compared with the results of postoperative pulmonary function tests. Regarding the linear correlation coefficients between the predicted postoperative values and the measured values, those obtained using the 3D-CT volumetry method tended to be higher than those acquired using the segment-counting method. In addition, the variations between the predicted and measured values were smaller with the 3D-CT volumetry method than with the segment-counting method. These results were more obvious in COPD patients than in non-COPD patients. Our findings suggested that the 3D-CT volumetry was able to predict the residual pulmonary function more accurately than the segment-counting method, especially in patients with COPD. This method might lead to the selection of appropriate candidates for surgery among patients with a marginal pulmonary function.
The Mid-Term Changes of Pulmonary Function Tests After Phrenic Nerve Transfer.
Yavari, Masoud; Hassanpour, Seyed Esmail; Khodayari, Mohammad
2016-03-01
In the restoration of elbow flexion, the phrenic nerve has proven to be a good donor, but considering the role of the phrenic nerve in respiratory function, we cannot disregard the potential dangers of this method. In the current study, we reviewed the results of pulmonary function tests (PFT) in four patients who underwent phrenic nerve transfer. We reviewed the results of serial spirometry tests, which were performed before and after phrenic nerve transfer surgery. All patients regained Biceps power to M3 strength or above. None of our patients experienced pulmonary problems or respiratory complaints, but a significant reduction of spirometric parameters occurred after surgery. This study highlights the close link between the role of the phrenic nerve and pulmonary function, such that the use of this nerve as a transfer donor leads to spirometric impairments.
Pulmonary Screening in Subjects after the Fontan Procedure.
Liptzin, Deborah R; Di Maria, Michael V; Younoszai, Adel; Narkewicz, Michael R; Kelly, Sarah L; Wolfe, Kelly R; Veress, Livia A
2018-05-07
To review the pulmonary findings of the first 51 patients who presented to our interdisciplinary single-ventricle clinic after undergoing the Fontan procedure. We performed an Institutional Review Board-approved retrospective review of 51 patients evaluated following the Fontan procedure. Evaluation included history, physical examination, pulmonary function testing, and 6-minute walk. Descriptive statistics were used to describe the population and testing data. Sixty-one percent of the patients had a pulmonary concern raised during the visit. Three patients had plastic bronchitis. Abnormal lung function testing was present in 46% of patients. Two-thirds (66%) of the patients had significant desaturation during the 6-minute walk test. Patients who underwent a fenestrated Fontan procedure and those who underwent unfenestrated Fontan were compared in terms of saturation and 6-minute walk test results. Sleep concerns were present in 45% of the patients. Pulmonary morbidities are common in patients after Fontan surgery and include plastic bronchitis, abnormal lung function, desaturations with walking, and sleep concerns. Abnormal lung function and obstructive sleep apnea may stress the Fontan circuit and may have implications for cognitive and emotional functioning. A pulmonologist involved in the care of patients after Fontan surgery can assist in screening for comorbidities and recommend interventions. Copyright © 2018 Elsevier Inc. All rights reserved.
Lee, Sung-soon; Kim, Changhwan; Jin, Young-Soo; Oh, Yeon-Mok; Lee, Sang-Do; Yang, Yun Jun; Park, Yong Bum
2013-05-01
Despite documented efficacy and recommendations, pulmonary rehabilitation (PR) in chronic obstructive pulmonary disease (COPD) has been underutilized. Home-based PR was proposed as an alternative, but there were limited data. The adequate exercise intensity was also a crucial issue. The aim of this study was to investigate the effects of home-based PR with a metronome-guided walking pace on functional exercise capacity and health-related quality of life (HRQOL) in COPD. The subjects participated in a 12-week home-based PR program. Exercise intensity was initially determined by cardiopulmonary exercise test, and was readjusted (the interval of metronome beeps was reset) according to submaximal endurance test. Six-minute walk test, pulmonary function test, cardiopulmonary exercise test, and St. George's Respiratory Questionnaire (SGRQ) were done before and after the 12-week program, and at 6 months after completion of rehabilitation. Thirty-three patients participated in the program. Six-minute walking distance was significantly increased (48.8 m; P = 0.017) and the SGRQ score was also improved (-15; P < 0.001) over the six-month follow-up period after rehabilitation. There were no significant differences in pulmonary function and peak exercise parameters. We developed an effective home-based PR program with a metronome-guided walking pace for COPD patients. This rehabilitation program may improve functional exercise capacity and HRQOL.
Ohno, Yoshiharu; Nishio, Mizuho; Koyama, Hisanobu; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Seki, Shinichiro; Obara, Makoto; van Cauteren, Marc; Takahashi, Masaya; Sugimura, Kazuro
2014-04-01
To assess the influence of ultrashort TE (UTE) intervals on pulmonary magnetic resonance imaging (MRI) with UTEs (UTE-MRI) for pulmonary functional loss assessment and clinical stage classification of smokers. A total 60 consecutive smokers (43 men and 17 women; mean age 70 years) with and without COPD underwent thin-section multidetector row computed tomography (MDCT), UTE-MRI, and pulmonary functional measurements. For each smoker, UTE-MRI was performed with three different UTE intervals (UTE-MRI A: 0.5 msec, UTE-MRI B: 1.0 msec, UTE-MRI C: 1.5 msec). By using the GOLD guidelines, the subjects were classified as: "smokers without COPD," "mild COPD," "moderate COPD," and "severe or very severe COPD." Then the mean T2* value from each UTE-MRI and CT-based functional lung volume (FLV) were correlated with pulmonary function test. Finally, Fisher's PLSD test was used to evaluate differences in each index among the four clinical stages. Each index correlated significantly with pulmonary function test results (P < 0.05). CT-based FLV and mean T2* values obtained from UTE-MRI A and B showed significant differences among all groups except between "smokers without COPD" and "mild COPD" groups (P < 0.05). UTE-MRI has a potential for management of smokers and the UTE interval is suggested as an important parameter in this setting. Copyright © 2013 Wiley Periodicals, Inc.
A computer system for processing data from routine pulmonary function tests.
Pack, A I; McCusker, R; Moran, F
1977-01-01
In larger pulmonary function laboratories there is a need for computerised techniques of data processing. A flexible computer system, which is used routinely, is described. The system processes data from a relatively large range of tests. Two types of output are produced--one for laboratory purposes, and one for return to the referring physician. The system adds an automatic interpretative report for each set of results. In developing the interpretative system it has been necessary to utilise a number of arbitrary definitions. The present terminology for reporting pulmonary function tests has limitations. The computer interpretation system affords the opportunity to take account of known interaction between measurements of function and different pathological states. Images PMID:329462
Imaging-based assessment of dyspnea in cigarette smokers
NASA Astrophysics Data System (ADS)
Galvin, Jeffrey R.; Chang, Paul J.; Schwartz, David A.; Hunninghake, Gary W.; Helmers, Richard; Mori, Masaki
1994-05-01
Patients with pulmonary fibrosis frequently smoke cigarettes. The cause of dyspnea in these patients is often complex because of the coexistence of multiple disease processes. We investigated 10 cigarette smokers with pulmonary fibrosis who were referred for evaluation of new onset or worsening dyspnea. Chest radiographs and pulmonary function tests were obtained in addition to high-resolution computed tomography (HRCT). In those patients with HRCT evidence of both diseases, spirometry and lung volumes were most often normal. Although plain films provided a reasonable assessment of fibrosis, they underestimated the severity of emphysema. Quantitation of both emphysema and fibrosis by HRCT was reproducible and correlated with key pulmonary function tests. Our findings indicate that the HRCT scan is a useful diagnostic test in patients with pulmonary fibrosis who are also cigarette smokers.
Pulmonary function and fuel use: a population survey.
Saha, Asim; Rao, N Mohan; Kulkarni, P K; Majumdar, P K; Saiyed, H N
2005-10-31
In the backdrop of conflicting reports (some studies reported adverse outcomes of biomass fuel use whereas few studies reported absence of any association between adverse health effect and fuel use, may be due to presence of large number of confounding variables) on the respiratory health effects of biomass fuel use, this cross sectional survey was undertaken to understand the role of fuel use on pulmonary function. This study was conducted in a village of western India involving 369 randomly selected adult subjects (165 male and 204 female). All the subjects were interviewed and were subjected to pulmonary function test. Analysis of covariance was performed to compare the levels of different pulmonary function test parameters in relation to different fuel use taking care of the role of possible confounding factors. This study showed that biomass fuel use (especially wood) is an important factor for deterioration of pulmonary function (particularly in female). FEV1 (p < .05), FEV1% (p < .01), PEFR (p < .05) and FEF(25-75) (p < .01) values were significantly lower in biomass fuel using females than nonusers. Comparison of only biomass fuel use vs. only LPG (Liquefied Petroleum Gas) use and only wood vs. only LPG use has showed that LPG is a safer fuel so far as deterioration of pulmonary function is concerned. This study observes some deterioration of pulmonary function in the male subjects also, who came from biomass fuel using families. This study concluded that traditional biomass fuels like wood have adverse effects on pulmonary function.
Non-invasive pulmonary function test on Morquio Patients
Kubaski, Francyne; Tomatsu, Shunji; Patel, Pravin; Shimada, Tsutomu; Xie, Li; Yasuda, Eriko; Mason, Robert; Mackenzie, William G.; Theroux, Mary; Bober, Michael B.; Oldham, Helen M.; Orii, Tadao; Shaffer, Thomas H.
2015-01-01
In clinical practice, respiratory function tests are difficult to perform in Morquio syndrome patients due to their characteristic skeletal dysplasia, small body size and lack of cooperation of young patients, where in some cases, conventional spirometry for pulmonary function is too challenging. To establish feasible clinical pulmonary endpoints and determine whether age impacts lung function in Morquio patients non-invasive pulmonary tests and conventional spirometry were evaluated. The non-invasive pulmonary tests: impulse oscillometry system, pneumotachography, and respiratory inductance plethysmography in conjunction with conventional spirometry were evaluated in twenty-two Morquio patients (18 Morquio A and 4 Morquio B) (7 males), ranging from 3 and 40 years of age. Twenty-two patients were compliant with non-invasive tests (100%) with exception of IOS (81.8%–18 patients). Seventeen patients (77.3%) were compliant with spirometry testing. All subjects had normal vital signs at rest including > 95% oxygen saturation, end tidal CO2 (38–44 mmHg), and age-appropriate heart rate (mean=98.3, standard deviation=19) (two patients were deviated). All patients preserved normal values in impulse oscillometry system, pneumotachography, and respiratory inductance plethysmography, although predicted forced expiratory volume total (72.8 ± 6.9 SE%) decreased with age and was below normal; phase angle (35.5 ± 16.5 Degrees), %Rib Cage (41.6 ± 12.7%), resonant frequency, and forced expiratory volume in one second/forced expiratory volume total (110.0 ± 3.2 SE%) were normal and not significantly impacted by age. The proposed non-invasive pulmonary function tests are able to cover a greater number of patients (young patients and/or wheel-chair bound), thus providing a new diagnostic approach for the assessment of lung function in Morquio syndrome which in many cases may be difficult to evaluate. Morquio patients studied herein demonstrated no clinical or functional signs of restrictive and/or obstructive lung disease. PMID:26116954
... clinical research. More Information Related Health Topics Asbestos-Related Lung Diseases Asthma Chest X-Ray COPD Cough Electrocardiogram Heart Failure How the Lungs Work Idiopathic Pulmonary Fibrosis Oxygen Therapy Sarcoidosis Stress Testing NHLBI Resources Taking a Spirometry Test Building ...
38 CFR 4.96 - Special provisions regarding evaluation of respiratory conditions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... purposes except when the results of pre-bronchodilator pulmonary function tests are normal or when the... schedule unless the post-bronchodilator results were poorer than the pre-bronchodilator results. In those...-6845. (1) Pulmonary function tests (PFT's) are required to evaluate these conditions except: (i) When...
38 CFR 4.96 - Special provisions regarding evaluation of respiratory conditions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... purposes except when the results of pre-bronchodilator pulmonary function tests are normal or when the... schedule unless the post-bronchodilator results were poorer than the pre-bronchodilator results. In those...-6845. (1) Pulmonary function tests (PFT's) are required to evaluate these conditions except: (i) When...
38 CFR 4.96 - Special provisions regarding evaluation of respiratory conditions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... purposes except when the results of pre-bronchodilator pulmonary function tests are normal or when the... schedule unless the post-bronchodilator results were poorer than the pre-bronchodilator results. In those...-6845. (1) Pulmonary function tests (PFT's) are required to evaluate these conditions except: (i) When...
38 CFR 4.96 - Special provisions regarding evaluation of respiratory conditions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... purposes except when the results of pre-bronchodilator pulmonary function tests are normal or when the... schedule unless the post-bronchodilator results were poorer than the pre-bronchodilator results. In those...-6845. (1) Pulmonary function tests (PFT's) are required to evaluate these conditions except: (i) When...
Pulmonary function and fuel use: A population survey
Saha, Asim; Mohan Rao, N; Kulkarni, PK; Majumdar, PK; Saiyed, HN
2005-01-01
Background In the backdrop of conflicting reports (some studies reported adverse outcomes of biomass fuel use whereas few studies reported absence of any association between adverse health effect and fuel use, may be due to presence of large number of confounding variables) on the respiratory health effects of biomass fuel use, this cross sectional survey was undertaken to understand the role of fuel use on pulmonary function. Method This study was conducted in a village of western India involving 369 randomly selected adult subjects (165 male and 204 female). All the subjects were interviewed and were subjected to pulmonary function test. Analysis of covariance was performed to compare the levels of different pulmonary function test parameters in relation to different fuel use taking care of the role of possible confounding factors. Results This study showed that biomass fuel use (especially wood) is an important factor for deterioration of pulmonary function (particularly in female). FEV1 (p < .05), FEV1 % (p < .01), PEFR (p < .05) and FEF25–75 (p < .01) values were significantly lower in biomass fuel using females than nonusers. Comparison of only biomass fuel use vs. only LPG (Liquefied Petroleum Gas) use and only wood vs. only LPG use has showed that LPG is a safer fuel so far as deterioration of pulmonary function is concerned. This study observes some deterioration of pulmonary function in the male subjects also, who came from biomass fuel using families. Conclusion This study concluded that traditional biomass fuels like wood have adverse effects on pulmonary function. PMID:16255784
Takai, Daiya
2014-12-01
Spirometry and the flow-volume curve test are commonly performed lung function tests. However, a unique clinical entity occasionally shows almost normal data in these tests, and is therefore missed on screening tests. The clinical entity of combined pulmonary emphysema and pulmdoary fibrosis was recognized and documented in the 90's in Japan, the USA, and Europe. Typical emphysema shows obstructive disorders, and pulmonary fibrosis shows restrictive disorders. Thus, the combination of both should lead to a combined disorder pattern in lung function tests, but this is not the case. In 2005, Cottin reported and redefined this combination of emphysema and fibrosis of the lung as "Combined Pulmonary Fibrosis and Emphysema" (CPFE). The patients are typically heavily smoking males who show an almost normal lung function. The upper lobe of these patients usually shows severe emphysema, which contributes to a static volume and a late phase in the forced volume test. On the other hand their lower lobe shows fibrotic change. The fibrotic portion contributes to early phase flow in the flow-volume curve. These mechanisms are a reason for the normal pattern appearance in lung function tests in CPFE patients. As a matter of course, these patients have damaged upper and lower lobes: their diffusing capacity of the lung shows a low performance, their saturation of blood hemoglobin decreases soon after light exercise, and their KL-6 (a blood marker of pulmonary fibrosis) usually shows a high value. They are considered a high risk group regarding complications of post-surgical treatment. Thus, when medical technologists identify suspicious cases, they should advise doctors to add diffusing capacity and KL-6 tests. (Review).
Bokov, P; Delclaux, C
2016-02-01
Resting pulmonary function tests (PFT) include the assessment of ventilatory capacity: spirometry (forced expiratory flows and mobilisable volumes) and static volume assessment, notably using body plethysmography. Spirometry allows the potential definition of obstructive defect, while static volume assessment allows the potential definition of restrictive defect (decrease in total lung capacity) and thoracic hyperinflation (increase in static volumes). It must be kept in mind that this evaluation is incomplete and that an assessment of ventilatory demand is often warranted, especially when facing dyspnoea: evaluation of arterial blood gas (searching for respiratory insufficiency) and measurement of the transfer coefficient of the lung, allowing with the measurement of alveolar volume to calculate the diffusing capacity of the lung for CO (DLCO: assessment of alveolar-capillary wall and capillary blood volume). All these pulmonary function tests have been the subject of an Americano-European Task force (standardisation of lung function testing) published in 2005, and translated in French in 2007. Interpretative strategies for lung function tests have been recommended, which define abnormal lung function tests using the 5th and 95th percentiles of predicted values (lower and upper limits of normal values). Thus, these recommendations need to be implemented in all pulmonary function test units. A methacholine challenge test will only be performed in the presence of an intermediate pre-test probability for asthma (diagnostic uncertainty), which is an infrequent setting. The most convenient exertional test is the 6-minute walk test that allows the assessment of walking performance, the search for arterial desaturation and the quantification of dyspnoea complaint. Copyright © 2015 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.
Cardio-Pulmonary Function Testing. Continuing Education Curriculum for Respiratory Therapy.
ERIC Educational Resources Information Center
Saint Paul Technical Vocational Inst., MN.
Compiled from interviews with personnel in pulmonary function testing (PFT) laboratories in the Minneapolis/St. Paul area, this competency-based curriculum guide is intended to provide a knowledge of PFT for persons who provide respiratory care. The guide contains 20 sections covering the following topics: vital capacity, flow measurements,…
Inapparent pulmonary vascular disease in an ex-heroin user
DOE Office of Scientific and Technical Information (OSTI.GOV)
Antonelli Incalzi, R.; Ludovico Maini, C.; Giuliano Bonetti, M.
1986-04-01
A severe pulmonary vascular derangement, usually reported in drug addicts, was diagnosed in a 28-year-old asymptomatic ex-heroin user by means of fortuitously performed pulmonary perfusion imaging. Neither physical findings nor pulmonary function tests, aroused suspicion of the diagnosis. A search for asymptomatic pulmonary vascular disease probably should be undertaken in drug addicts.
Ohno, Yoshiharu; Nishio, Mizuho; Koyama, Hisanobu; Takenaka, Daisuke; Takahashi, Masaya; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Obara, Makoto; van Cauteren, Marc; Sugimura, Kazuro
2013-08-01
To evaluate the utility of pulmonary magnetic resonance (MR) imaging with ultra-short echo times (UTEs) at a 3.0 T MR system for pulmonary functional loss and disease severity assessments of connective tissue disease (CTD) patients with interstitial lung disease (ILD). This prospective study was approved by the institutional review board, and written informed consent was obtained from 18 CTD patients (eight men and ten women) and eight normal subjects with suspected chest disease (three men and five women). All subjects underwent thin-section MDCT, pulmonary MR imaging with UTEs, pulmonary function test and serum KL-6. Regional T2 maps were generated from each MR data set, and mean T2 values were determined from ROI measurements. From each thin-section MDCT data set, CT-based disease severity was evaluated with a visual scoring system. Mean T2 values for normal and CTD subjects were statistically compared by using Student's t-test. To assess capability for pulmonary functional loss and disease severity assessments, mean T2 values were statistically correlated with pulmonary functional parameters, serum KL-6 and CT-based disease severity. Mean T2 values for normal and CTD subjects were significantly different (p=0.0019) and showed significant correlations with %VC, %DLCO, serum KL-6 and CT-based disease severity of CTD patients (p<0.05). Pulmonary MR imaging with UTEs is useful for pulmonary functional loss and disease severity assessments of CTD patients with ILD. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Trajectories of change in cognitive function in people with chronic obstructive pulmonary disease.
Park, Soo Kyung
2018-04-01
To describe changes in cognitive function, as measured by the trail making test; to identify distinct patterns of change in cognitive function; and to examine predictors of change in cognitive function in people with severe chronic obstructive pulmonary disease. How cognitive function changes in people with chronic obstructive pulmonary disease and what factors influence those changes over time is not well known, despite the fact that it declines rapidly in this population and significantly impacts functional decline in healthy older adults. A secondary analysis and longitudinal study with a follow-up period of 3 years. A data set from the National Emphysema Treatment Trial provided participant data. Patients with severe chronic obstructive pulmonary disease (n = 307) were recruited at a clinical site. Several demographic and clinical measures were assessed at baseline. Trail making test scores were measured at baseline, 1, 2 and 3 years. Cognitive function was stable for 3 years in people with chronic obstructive pulmonary disease. However, four distinct patterns of change in cognitive function were identified. Age, education, 6-min walk distance and cognitive impairment scores at baseline on the trail making test Part B were significant predictors of worsening cognitive function and below-average cognitive function over 3 years. These findings suggest that increasing exercise capacity improves cognitive function and delays deterioration of cognitive function in people with COPD. Understanding the trajectories of change in cognitive function and predictors of change in cognitive function over 3 years may enable health care providers to identify patients at greatest risk of developing mental deterioration and those who might benefit from interventions to improve cognitive function. Health care providers should periodically assess and frequently screen people with COPD for cognitive function. © 2018 John Wiley & Sons Ltd.
Pulmonary function evaluation during and following Skylab space flights
NASA Technical Reports Server (NTRS)
Sawin, C. F.; Nicogossian, A. E.; Schachter, A. P.; Rummel, J. A.; Michel, E. L.
1974-01-01
Previous experience during the Apollo postflight exercise testing indicated no major changes in pulmonary function. Although pulmonary function has been studied in detail following exposure to hypoxic and hyperoxic environments, few studies have dealt with normoxic environments at reduced total pressure as encountered during the Skylab missions. Forced vital capacity was measured during the preflight and postflight periods of the Skylab 2 mission. Initial in-flight measurements of vital capacity were obtained during the last two weeks of the second manned mission (Skylab 3). Comprehensive pulmonary function screening was accomplished during the Skylab 4 mission. The primary measurements made during Skylab 4 testing included residual volume determination, closing volume, vital capacity, and forced vital capacity and its derivatives. In addition, comprehensive in-flight vital capacity measurements were made during the Skylab 4 mission. Vital capacity was decreased slightly during flight in all Skylab 4 crewmen. No major preflight to postflight changes were observed in the other parameters.
An automated system for pulmonary function testing
NASA Technical Reports Server (NTRS)
Mauldin, D. G.
1974-01-01
An experiment to quantitate pulmonary function was accepted for the space shuttle concept verification test. The single breath maneuver and the nitrogen washout are combined to reduce the test time. Parameters are defined from the forced vital capacity maneuvers. A spirometer measures the breath volume and a magnetic section mass spectrometer provides definition of gas composition. Mass spectrometer and spirometer data are analyzed by a PDP-81 digital computer.
Abolmaali, Nasreddin; Koch, Arne; Götzelt, Knut; Hahn, Gabriele; Fitze, Guido; Vogelberg, Christian
2010-07-01
To compare MRI-based functional pulmonary and cardiac measurements in the long-term follow-up of children operated on for left-sided congenital diaphragmatic hernia (CDH) with age- and body size-matched healthy controls. Twelve children who received immediate postnatal surgery for closure of isolated left-sided CDH were included and received basic medical examinations, pulmonary function testing and echocardiography. MRI included measurement of lung volume, ventricular function assessment and velocity-encoded imaging of the pulmonary arteries and was compared with the data for 12 healthy children matched for age and body size. While patients' clinical test results were not suspicious, comparison between the MRI data for patients and those for healthy controls revealed significant differences. In patients, the volumes of the left lungs were increased and the tidal volume was larger on the right side. While the stroke volumes of both ventricles were reduced, heart rate and ejection fraction were increased. Flow, acceleration time and cross-sectional area of the left pulmonary artery were reduced. Functional MRI detected pulmonary and cardiac findings in the late follow-up of CDH children which may be missed by standard clinical methods and might be relevant for decisions regarding late outcome and treatment.
Effect of added mass on treadmill performance and pulmonary function.
Walker, Rachel E; Swain, David P; Ringleb, Stacie I; Colberg, Sheri R
2015-04-01
Military personnel engage in strenuous physical activity and load carriage. This study evaluated the role of body mass and of added mass on aerobic performance (uphill treadmill exercise) and pulmonary function. Performance on a traditional unloaded run test (4.8 km) was compared with performance on loaded tasks. Subjects performed an outdoor 4.8-km run and 4 maximal treadmill tests wearing loads of 0, 10, 20, and 30 kg. Subjects' pulmonary function (forced expired volume in 1 second [FEV1], forced vital capacity [FVC], and maximal voluntary ventilation [MVV]) was tested with each load, and peak values of heart rate, oxygen consumption ((Equation is included in full-text article.)), ventilation (VE), and respiratory exchange ratio (RER) were measured during each treadmill test. Performance on the 4.8-km run was correlated with treadmill performance, measured as time to exhaustion (TTE), with the strength of the correlation decreasing with load (r = 0.87 for 0 kg to 0.76 for 30 kg). Body mass was not correlated with TTE, other than among men with the 30-kg load (r = 0.48). During treadmill exercise, all peak responses other than RER decreased with load. Pulmonary function measures (FEV1, FVC, and MVV) decreased with load. Body mass was poorly correlated with treadmill performance, but added mass decreased performance. The decreased performance may be in part because of decreased pulmonary function. Unloaded 4.8-km run performance was correlated to unloaded uphill treadmill performance, but less so as load increased. Therefore, traditional run tests may not be an effective means of evaluating aerobic performance for military field operations.
Reversibility of trapped air on chest computed tomography in cystic fibrosis patients.
Loeve, Martine; Rosenow, Tim; Gorbunova, Vladlena; Hop, Wim C J; Tiddens, Harm A W M; de Bruijne, Marleen
2015-06-01
To investigate changes in trapped air volume and distribution over time and compare computed tomography (CT) with pulmonary function tests for determining trapped air. Thirty children contributed two CTs and pulmonary function tests over 2 years. Localized changes in trapped air on CT were assessed using image analysis software, by deforming the CT at timepoint 2 to match timepoint 1, and measuring the volume of stable (TAstable), disappeared (TAdisappeared) and new (TAnew) trapped air as a proportion of total lung volume. We used the difference between total lung capacity measured by plethysmography and helium dilution, residual volume to total lung capacity ratio, forced expiratory flow at 75% of vital capacity, and maximum mid-expiratory flow as pulmonary function test markers of trapped air. Statistical analysis included Wilcoxon's signed rank test and Spearman correlation coefficients. Median (range) age at baseline was 11.9 (5-17) years. Median (range) of trapped air was 9.5 (2-33)% at timepoint 1 and 9.0 (0-25)% at timepoint 2 (p=0.49). Median (range) TAstable, TAdisappeared and TAnew were respectively 3.0 (0-12)%, 5.0 (1-22)% and 7.0 (0-20)%. Trapped air on CT correlated statistically significantly with all pulmonary function measures (p<0.01), other than residual volume to total lung capacity ratio (p=0.37). Trapped air on CT did not significantly progress over 2 years, may have a substantial stable component, and is significantly correlated with pulmonary function markers. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Schmitt, Todd L; Munns, Suzanne; Adams, Lance; Hicks, James
2013-09-01
This study utilized computed spirometry to compare the pulmonary function of two stranded olive ridley sea turtles (Lepidochelys olivacea) presenting with a positive buoyancy disorder with two healthy captive olive ridley sea turtles held in a large public aquarium. Pulmonary function test (PFT) measurements demonstrated that the metabolic cost of breathing was much greater for animals admitted with positive buoyancy than for the normal sea turtles. Positively buoyant turtles had higher tidal volumes and significantly lower breathing-frequency patterns with significantly higher expiration rates, typical of gasp-type breathing. The resulting higher energetic cost of breathing in the diseased turtles may have a significant impact on their long-term survival. The findings represent a method for clinical respiratory function analysis for an individual animal to assist with diagnosis, therapy, and prognosis. This is the first study, to our knowledge, to evaluate objectively sea turtles presenting with positive buoyancy and respiratory disease using pulmonary function tests.
Modulation of Lung Function by Increased Nitric Oxide Production
Yadav, Ram Lochan; Yadav, Prakash Kumar
2017-01-01
Introduction Cigarette smoking reduces endogenous Nitric Oxide (NO) production by reducing Nitric Oxide Synthase (NOS) activity, which is one of the probable reason for increased rate of pulmonary diseases in smokers. Nitric oxide/oxygen blends are used in critical care to promote capillary and pulmonary dilation to treat several pulmonary vascular diseases. Among several supplements, the highest NOS activation has been proved for garlic with its unique mechanism of action. Aim To investigate the effect of dietary supplementation of NO producing garlic on pulmonary function of smokers. Materials and Methods The study was conducted on 40 healthy non-smoker (Group A) and 40 chronic smoker (Group B) males with matched age, height and weight. The pulmonary function tests- Forced Vital Capacity (FVC), Forced Expiratory Volume in one second (FEV1), FEV1/FVC ratio and Peak Expiratory Flow Rate (PEFR) were performed in non-smokers (Group A), smokers (Group B) and smokers after supplementation of approximately 4 gm of raw garlic (2 garlic cloves) per day for three months (Group C). Endogenous NO production was studied in smokers before and after garlic supplementation and in non-smokers without supplementation. The data obtained were compared between the groups using unpaired student’s t-test. The p-value considered significant at <0.05. Results Our results showed that FVC, FEV1, FEV1/FVC ratio and PEFR were reduced significantly along with a significant decreased NOS activity among smokers (Group B) when compared with non-smokers (Group A). Garlic supplementation significantly improved the pulmonary function tests in Group C in comparison to Group B by increasing NOS activity. Conclusion Dietary supplementation of garlic, which might be by increasing NOS activity, has significantly improved pulmonary functions in smokers. PMID:28764150
Classification Models for Pulmonary Function using Motion Analysis from Phone Sensors.
Cheng, Qian; Juen, Joshua; Bellam, Shashi; Fulara, Nicholas; Close, Deanna; Silverstein, Jonathan C; Schatz, Bruce
2016-01-01
Smartphones are ubiquitous, but it is unknown what physiological functions can be monitored at clinical quality. Pulmonary function is a standard measure of health status for cardiopulmonary patients. We have shown phone sensors can accurately measure walking patterns. Here we show that improved classification models can accurately measure pulmonary function, with sole inputs being sensor data from carried phones. Twenty-four cardiopulmonary patients performed six minute walk tests in pulmonary rehabilitation at a regional hospital. They carried smartphones running custom software recording phone motion. For every patient, every ten-second interval was correctly computed. The trained model perfectly computed the GOLD level 1/2/3, which is a standard categorization of pulmonary function as measured by spirometry. These results are encouraging towards field trials with passive monitors always running in the background. We expect patients can simply carry their phones during daily living, while supporting automatic computation ofpulmonary function for health monitoring.
Kelly, Robert E; Mellins, Robert B; Shamberger, Robert C; Mitchell, Karen K; Lawson, M Louise; Oldham, Keith T; Azizkhan, Richard G; Hebra, Andre V; Nuss, Donald; Goretsky, Michael J; Sharp, Ronald J; Holcomb, George W; Shim, Walton K T; Megison, Stephen M; Moss, R Lawrence; Fecteau, Annie H; Colombani, Paul M; Cooper, Dan; Bagley, Traci; Quinn, Amy; Moskowitz, Alan B; Paulson, James F
2013-12-01
A multicenter study of pectus excavatum was described previously. This report presents our final results. Patients treated surgically at 11 centers were followed prospectively. Each underwent a preoperative evaluation with CT scan, pulmonary function tests, and body image survey. Data were collected about associated conditions, complications, and perioperative pain. One year after treatment, patients underwent repeat chest CT scan, pulmonary function tests, and body image survey. A subset of 50 underwent exercise pulmonary function testing. Of 327 patients, 284 underwent Nuss procedure and 43 underwent open procedure without mortality. Of 182 patients with complete follow-up (56%), 18% had late complications, similarly distributed, including substernal bar displacement in 7% and wound infection in 2%. Mean initial CT scan index of 4.4 improved to 3.0 post operation (severe >3.2, normal = 2.5). Computed tomography index improved at the deepest point (xiphoid) and also upper and middle sternum. Pulmonary function tests improved (forced vital capacity from 88% to 93%, forced expiratory volume in 1 second from 87% to 90%, and total lung capacity from 94% to 100% of predicted (p < 0.001 for each). VO2 max during peak exercise increased by 10.1% (p = 0.015) and O2 pulse by 19% (p = 0.007) in 20 subjects who completed both pre- and postoperative exercise tests. There is significant improvement in lung function at rest and in VO2 max and O2 pulse after surgical correction of pectus excavatum, with CT index >3.2. Operative correction significantly reduces CT index and markedly improves the shape of the entire chest, and can be performed safely in a variety of centers. Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Taichman, Darren B; Christie, Jason; Biester, Rosette; Mortensen, Jennifer; White, Joanne; Kaplan, Sandra; Hansen-Flaschen, John; Palevsky, Harold I; Elliott, C Gregory; Hopkins, Ramona O
2005-04-25
The effects of pulmonary arterial hypertension on brain function are not understood, despite patients' frequent complaints of cognitive difficulties. Using clinical instruments normally administered during standard in-person assessment of neurocognitive function in adults, we assembled a battery of tests designed for administration over the telephone. The purpose was to improve patient participation, facilitate repeated test administration, and reduce the cost of research on the neuropsychological consequences of acute and chronic cardiorespiratory diseases. We undertook this study to validate telephone administration of the tests. 23 adults with pulmonary arterial hypertension underwent neurocognitive assessment using both standard in-person and telephone test administration, and the results of the two methods compared using interclass correlations. For most of the tests in the battery, scores from the telephone assessment correlated strongly with those obtained by in-person administration of the same tests. Interclass correlations between 0.5 and 0.8 were observed for tests that assessed attention, memory, concentration/working memory, reasoning, and language/crystallized intelligence (p < or = 0.05 for each). Interclass correlations for the Hayling Sentence Completion test of executive function approached significance (p = 0.09). All telephone tests were completed within one hour. Administration of this neurocognitive test battery by telephone should facilitate assessment of neuropsychological deficits among patients with pulmonary arterial hypertension living across broad geographical areas, and may be useful for monitoring changes in neurocognitive function in response to PAH-specific therapy or disease progression.
Benattia, Amira; Debeaumont, David; Guyader, Vincent; Tardif, Catherine; Peillon, Christophe; Cuvelier, Antoine; Baste, Jean-Marc
2016-06-01
Impaired respiratory function may prevent curative surgery for patients with non-small cell lung cancer (NSCLC). Video-assisted thoracoscopic surgery (VATS) reduces postoperative morbility-mortality and could change preoperative assessment practices and therapeutic decisions. We evaluated the relation between preoperative pulmonary function tests and the occurrence of postoperative complications after VATS pulmonary resection in patients with abnormal pulmonary function. We included 106 consecutive patients with ≤80% predicted value of presurgical expiratory volume in one second (FEV1) and/or diffusing capacity of carbon monoxide (DLCO) and who underwent VATS pulmonary resection for NSCLC from a prospective surgical database. Patients (64±9.5 years) had lobectomy (n=91), segmentectomy (n=7), bilobectomy (n=4), or pneumonectomy (n=4). FEV1 and DLCO preoperative averages were 68%±21% and 60%±18%. Operative mortality was 1.89%. Only FEV1 was predictive of postoperative complications [odds ratio (OR), 0.96; 95% confidence interval (CI), 0.926-0.991, P=0.016], but there was no determinable threshold. Twenty-five patients underwent incremental exercise testing. Desaturations during exercise (OR, 0.462; 95% CI, 0.191-0.878, P=0.039) and heart rate (HR) response (OR, 0.953; 95% CI, 0.895-0.993, P=0.05) were associated with postoperative complications. FEV1 but not DLCO was a significant predictor of pulmonary complications after VATS pulmonary resection despite a low rate of severe morbidity. Incremental exercise testing seems more discriminating. Further investigation is required in a larger patient population to change current pre-operative threshold in a new era of minimally invasive surgery.
Le Roux, Pierre-Yves; Siva, Shankar; Steinfort, Daniel P; Callahan, Jason; Eu, Peter; Irving, Lou B; Hicks, Rodney J; Hofman, Michael S
2015-11-01
Pulmonary function tests (PFTs) are routinely used to assess lung function, but they do not provide information about regional pulmonary dysfunction. We aimed to assess correlation of quantitative ventilation-perfusion (V/Q) PET/CT with PFT indices. Thirty patients underwent V/Q PET/CT and PFT. Respiration-gated images were acquired after inhalation of (68)Ga-carbon nanoparticles and administration of (68)Ga-macroaggregated albumin. Functional volumes were calculated by dividing the volume of normal ventilated and perfused (%NVQ), unmatched and matched defects by the total lung volume. These functional volumes were correlated with forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), FEV1/FVC, and diffusing capacity for carbon monoxide (DLCO). All functional volumes were significantly different in patients with chronic obstructive pulmonary disease (P < 0.05). FEV1/FVC and %NVQ had the highest correlation (r = 0.82). FEV1 was also best correlated with %NVQ (r = 0.64). DLCO was best correlated with the volume of unmatched defects (r = -0.55). Considering %NVQ only, a cutoff value of 90% correctly categorized 28 of 30 patients with or without significant pulmonary function impairment. Our study demonstrates strong correlations between V/Q PET/CT functional volumes and PFT parameters. Because V/Q PET/CT is able to assess regional lung function, these data support the feasibility of its use in radiation therapy and preoperative planning and assessing pulmonary dysfunction in a variety of respiratory diseases. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Severgnini, Paolo; Selmo, Gabriele; Lanza, Christian; Chiesa, Alessandro; Frigerio, Alice; Bacuzzi, Alessandro; Dionigi, Gianlorenzo; Novario, Raffaele; Gregoretti, Cesare; de Abreu, Marcelo Gama; Schultz, Marcus J; Jaber, Samir; Futier, Emmanuel; Chiaranda, Maurizio; Pelosi, Paolo
2013-06-01
The impact of intraoperative ventilation on postoperative pulmonary complications is not defined. The authors aimed at determining the effectiveness of protective mechanical ventilation during open abdominal surgery on a modified Clinical Pulmonary Infection Score as primary outcome and postoperative pulmonary function. Prospective randomized, open-label, clinical trial performed in 56 patients scheduled to undergo elective open abdominal surgery lasting more than 2 h. Patients were assigned by envelopes to mechanical ventilation with tidal volume of 9 ml/kg ideal body weight and zero-positive end-expiratory pressure (standard ventilation strategy) or tidal volumes of 7 ml/kg ideal body weight, 10 cm H2O positive end-expiratory pressure, and recruitment maneuvers (protective ventilation strategy). Modified Clinical Pulmonary Infection Score, gas exchange, and pulmonary functional tests were measured preoperatively, as well as at days 1, 3, and 5 after surgery. Patients ventilated protectively showed better pulmonary functional tests up to day 5, fewer alterations on chest x-ray up to day 3 and higher arterial oxygenation in air at days 1, 3, and 5 (mmHg; mean ± SD): 77.1 ± 13.0 versus 64.9 ± 11.3 (P = 0.0006), 80.5 ± 10.1 versus 69.7 ± 9.3 (P = 0.0002), and 82.1 ± 10.7 versus 78.5 ± 21.7 (P = 0.44) respectively. The modified Clinical Pulmonary Infection Score was lower in the protective ventilation strategy at days 1 and 3. The percentage of patients in hospital at day 28 after surgery was not different between groups (7 vs. 15% respectively, P = 0.42). A protective ventilation strategy during abdominal surgery lasting more than 2 h improved respiratory function and reduced the modified Clinical Pulmonary Infection Score without affecting length of hospital stay.
Rehman, Michaela B; Garcia, Rodrigue; Christiaens, Luc; Larrieu-Ardilouze, Elisa; Howard, Luke S; Nihoyannopoulos, Petros
2018-04-15
Right ventricular function is the major determinant of morbidity and mortality in pulmonary arterial hypertension (PAH). The ESC risk assessment strategy for PAH is based on clinical status, exercise testing, NTproBNP, imaging and haemodynamics but does not include right ventricular function. Our aims were to test the power of resting echocardiographic measurements to classify PAH patients according to ESC exercise testing risk stratification cut-offs and to determine if the classification power of echocardiographic parameters varied in chronic thrombo-embolic pulmonary hypertension (CTEPH). We prospectively and consecutively recruited 46 PAH patients and 42 CTEPH patients referred for cardio-pulmonary exercise testing and comprehensive transthoracic echocardiography. Exercise testing parameters analyzed were peak oxygen consumption, percentage of predicted maximal oxygen consumption and the slope of ventilation against carbon dioxide production. Receiver operator characteristic curves were used to determine the optimal diagnostic cut-off values of echocardiographic parameters for classifying the patients in intermediate or high risk category according to exercise testing. Measurements of right ventricular systolic function were the best for classifying in PAH (area under the curve 0.815 to 0.935). Measurements of right ventricular pressure overload (0.810 to 0.909) were optimal for classifying according to exercise testing in CTEPH. Measurements of left ventricular function were of no use in either group. Measurements of right ventricular systolic function can classify according to exercise testing risk stratification cut-offs in PAH. However, this is not the case in CTEPH where pressure overload, rather than right ventricular function seems to be linked to exercise performance. Copyright © 2018 Elsevier B.V. All rights reserved.
Impaired pulmonary function after treatment for tuberculosis: the end of the disease?
Chushkin, Mikhail Ivanovich; Ots, Oleg Nikolayevich
2017-01-01
To evaluate the prevalence of pulmonary function abnormalities and to investigate the factors affecting lung function in patients treated for pulmonary tuberculosis. A total of 214 consecutive patients (132 men and 82 women; 20-82 years of age), treated for pulmonary tuberculosis and followed at a local dispensary, underwent spirometry and plethysmography at least one year after treatment. Pulmonary impairment was present in 102 (47.7%) of the 214 patients evaluated. The most common functional alteration was obstructive lung disease (seen in 34.6%). Of the 214 patients, 60 (28.0%) showed reduced pulmonary function (FEV1 below the lower limit of normal). Risk factors for reduced pulmonary function were having had culture-positive pulmonary tuberculosis in the past, being over 50 years of age, having recurrent tuberculosis, and having a lower level of education. Nearly half of all tuberculosis patients evolve to impaired pulmonary function. That underscores the need for pulmonary function testing after the end of treatment. Avaliar a prevalência de alterações da função pulmonar e investigar os fatores que afetam a função pulmonar em pacientes tratados para tuberculose pulmonar. Um total de 214 pacientes consecutivos (132 homens e 82 mulheres; 20-82 anos de idade), tratados para tuberculose pulmonar e acompanhados em um dispensário local, foi submetido a espirometria e pletismografia pelo menos um ano após o tratamento. O comprometimento pulmonar estava presente em 102 (47,7%) dos 214 pacientes avaliados. A alteração funcional mais comum foi o distúrbio ventilatório obstrutivo (observado em 34,6%). Dos 214 pacientes, 60 (28,0%) apresentaram função pulmonar reduzida (VEF1 abaixo do limite inferior de normalidade). Os fatores de risco para função pulmonar reduzida foram tuberculose pulmonar com cultura positiva no passado, idade acima de 50 anos, recidiva de tuberculose e menor nível de escolaridade. Quase metade de todos os pacientes com tuberculose evolui com comprometimento da função pulmonar. Isso reforça a necessidade de testes de função pulmonar após o término do tratamento.
Effect of exercise test on pulmonary function of obese adolescents.
Faria, Alethéa Guimarães; Ribeiro, Maria Angela G O; Marson, Fernando Augusto Lima; Schivinski, Camila Isabel S; Severino, Silvana Dalge; Ribeiro, José Dirceu; Barros Filho, Antônio A
2014-01-01
to investigate the pulmonary response to exercise of non-morbidly obese adolescents, considering the gender. a prospective cross-sectional study was conducted with 92 adolescents (47 obese and 45 eutrophic), divided in four groups according to obesity and gender. Anthropometric parameters, pulmonary function (spirometry and oxygen saturation [SatO2]), heart rate (HR), blood pressure (BP), respiratory rate (RR), and respiratory muscle strength were measured. Pulmonary function parameters were measured before, during, and after the exercise test. BP and HR were higher in obese individuals during the exercise test (p = 0.0001). SatO2 values decreased during exercise in obese adolescents (p = 0.0001). Obese males had higher levels of maximum inspiratory and expiratory pressures (p = 0.0002) when compared to obese and eutrophic females. Obese males showed lower values of maximum voluntary ventilation, forced vital capacity, and forced expiratory volume in the first second when compared to eutrophic males, before and after exercise (p = 0.0005). Obese females had greater inspiratory capacity compared to eutrophic females (p = 0.0001). Expiratory reserve volume was lower in obese subjects when compared to controls (p ≤ 0,05). obese adolescents presented changes in pulmonary function at rest and these changes remained present during exercise. The spirometric and cardiorespiratory values were different in the four study groups. The present data demonstrated that, in spite of differences in lung growth, the model of fat distribution alters pulmonary function differently in obese female and male adolescents. Copyright © 2013 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
Günay, Ersin; Kaymaz, Dicle; Selçuk, Nursel Türkoglu; Ergün, Pinar; Sengül, Fatma; Demir, Nese
2013-11-01
Chronic obstructive pulmonary disease (COPD) is considered a worldwide major public health problem. Weight loss, muscle and fat mass depletion are common nutritional problems in COPD patients and are determinant factors in pulmonary function, health status, disability and mortality. We aimed to assess the relationships between nutritional status and perception of dyspnoea, pulmonary function tests (PFT), exercise capacity and health-related quality of life (HRQoL) using the subjective global assessment (SGA) in COPD patients who were referred for pulmonary rehabilitation programme. A total of 163 patients with stable COPD who are candidates for outpatient pulmonary rehabilitation programme were included in this study. Nutritional status for all patients was assessed by SGA. Association of SGA scores (A, B and C) and anthropometric measurements, PFT, dyspnoea scales (Medical Research Council and resting BORG scale), HRQoL (St. George Respiratory Questionnaire and Chronic Respiratory Diseases Questionnaire) and exercise testing (shuttle walking test) were studied for statistical significance. Based on SGA, 9.2% of patients were severely malnourished (SGA-C). There were significant decreases in forced expiratory volume in the first second (FEV1 ) (P = 0.009), Medical Research Council scales (P < 0.001) and exercise capacity (incremental shuttle walking test (P = 0.001) and endurance shuttle walking test (P = 0.009)) in SGA-C. Deterioration in anthropometric measurements and HRQoL measures were observed in malnourished patients. Identifying the nutritional status and determining any requirement for nutritional supplement is an important component of comprehensive pulmonary rehabilitation programme. SGA is an easy and practical method to assess nutritional status in pulmonary rehabilitation candidate patients with stable COPD. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.
Su, Junjing; Manisty, Charlotte; Simonsen, Ulf; Howard, Luke S; Parker, Kim H; Hughes, Alun D
2017-10-15
Wave travel plays an important role in cardiovascular physiology. However, many aspects of pulmonary arterial wave behaviour remain unclear. Wave intensity and reservoir-excess pressure analyses were applied in the pulmonary artery in subjects with and without pulmonary hypertension during spontaneous respiration and dynamic stress tests. Arterial wave energy decreased during expiration and Valsalva manoeuvre due to decreased ventricular preload. Wave energy also decreased during handgrip exercise due to increased heart rate. In pulmonary hypertension patients, the asymptotic pressure at which the microvascular flow ceases, the reservoir pressure related to arterial compliance and the excess pressure caused by waves increased. The reservoir and excess pressures decreased during Valsalva manoeuvre but remained unchanged during handgrip exercise. This study provides insights into the influence of pulmonary vascular disease, spontaneous respiration and dynamic stress tests on pulmonary artery wave propagation and reservoir function. Detailed haemodynamic analysis may provide novel insights into the pulmonary circulation. Therefore, wave intensity and reservoir-excess pressure analyses were applied in the pulmonary artery to characterize changes in wave propagation and reservoir function during spontaneous respiration and dynamic stress tests. Right heart catheterization was performed using a pressure and Doppler flow sensor tipped guidewire to obtain simultaneous pressure and flow velocity measurements in the pulmonary artery in control subjects and patients with pulmonary arterial hypertension (PAH) at rest. In controls, recordings were also obtained during Valsalva manoeuvre and handgrip exercise. The asymptotic pressure at which the flow through the microcirculation ceases, the reservoir pressure related to arterial compliance and the excess pressure caused by arterial waves increased in PAH patients compared to controls. The systolic and diastolic rate constants also increased, while the diastolic time constant decreased. The forward compression wave energy decreased by ∼8% in controls and ∼6% in PAH patients during expiration compared to inspiration, while the wave speed remained unchanged throughout the respiratory cycle. Wave energy decreased during Valsalva manoeuvre (by ∼45%) and handgrip exercise (by ∼27%) with unaffected wave speed. Moreover, the reservoir and excess pressures decreased during Valsalva manoeuvre but remained unaltered during handgrip exercise. In conclusion, reservoir-excess pressure analysis applied to the pulmonary artery revealed distinctive differences between controls and PAH patients. Variations in the ventricular preload and afterload influence pulmonary arterial wave propagation as demonstrated by changes in wave energy during spontaneous respiration and dynamic stress tests. © 2017 The Authors. The Journal of Physiology © 2017 The Physiological Society.
Saito, Hajime; Hatakeyama, Kazutoshi; Konno, Hayato; Matsunaga, Toshiki; Shimada, Yoichi; Minamiya, Yoshihiro
2017-09-01
Given the extent of the surgical indications for pulmonary lobectomy in breathless patients, preoperative care and evaluation of pulmonary function are increasingly necessary. The aim of this study was to assess the contribution of preoperative pulmonary rehabilitation (PR) for reducing the incidence of postoperative pulmonary complications in non-small cell lung cancer (NSCLC) patients with chronic obstructive pulmonary disease (COPD). The records of 116 patients with COPD, including 51 patients who received PR, were retrospectively analyzed. Pulmonary function testing, including slow vital capacity (VC) and forced expiratory volume in one second (FEV 1 ), was obtained preoperatively, after PR, and at one and six months postoperatively. The recovery rate of postoperative pulmonary function was standardized for functional loss associated with the different resected lung volumes. Propensity score analysis generated matched pairs of 31 patients divided into PR and non-PR groups. The PR period was 18.7 ± 12.7 days in COPD patients. Preoperative pulmonary function was significantly improved after PR (VC 5.3%, FEV 1 5.5%; P < 0.05). The FEV 1 recovery rate one month after surgery was significantly better in the PR (101.6%; P < 0.001) than in the non-PR group (93.9%). In logistic regression analysis, predicted postoperative FEV 1 , predicted postoperative %FEV 1 , and PR were independent factors related to postoperative pulmonary complications after pulmonary lobectomy (odds ratio 18.9, 16.1, and 13.9, respectively; P < 0.05). PR improved the recovery rate of pulmonary function after lobectomy in the early period, and may decrease postoperative pulmonary complications. © 2017 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.
Pulmonary function test in formalin exposed and nonexposed subjects: A comparative study
Uthiravelu, P.; Saravanan, A.; Kumar, C. Kishor; Vaithiyanandane, V.
2015-01-01
Background: The main function of the lung is gas exchange, which can be assessed in several ways. A spirometer measures the flow and the volumes of the inspired and expired air. The thoracic and abdominal muscle strength plays an important role in pulmonary function and diffusing lung capacity. Aims and Objectives: The aim of this study was to assess the effects of formalin exposure on the pulmonary function to compare with healthy individuals. To assess the chronic effects of formalin exposure on Pulmonary function tests (PFTs) in the faculties, lab technicians and attender of the Department of Anatomy and Pathology of SRM Medical Hospital and Research Centre, Kattankulathur. Materials and Methods: This prospective study was carried out in 50 healthy formalin exposed subjects (at least 5 years exposure) from Department of Anatomy and Pathology of SRM Medical College Hospital and Research Centre, Kattankulathur and 50 healthy controls of same age group of this study were included after obtaining ethical clearance and consent ‘Easy One Pro Spirometer (Ndd Medical Technologies, Cheshire SK 101LT, United Kingdom) was used to find out the PFT. Results: Student's t-test was applied to compare the PFT parameters between formalin exposed and formalin nonexposed group. There was a significant difference in mean and standard deviation of pulmonary parameters with the P < 0.005 in formalin exposed, which shows that they have lesser ventilatory drive. Conclusion: The formalin exposed subjects in our study presented with a mixed disorder of both obstructive and restrictive type. We also found that there was a negative correlation of pulmonary function with that of the degree and duration of exposure to formalin. PMID:26015743
The impact of bariatric surgery on pulmonary function: a meta-analysis.
Alsumali, Adnan; Al-Hawag, Ali; Bairdain, Sigrid; Eguale, Tewodros
2018-02-01
Morbid obesity may affect several body systems and cause ill effects to the cardiovascular, hepatobiliary, endocrine, and mental health systems. However, the impact on the pulmonary system and pulmonary function has been debated in the literature. A systematic review and meta-analysis for studies that have evaluated the impact of bariatric surgery on pulmonary function were pooled for this analysis. PubMed, Cochrane, and Embase databases were evaluated through September 31, 2016. They were used as the primary search engine for studies evaluating the impact pre- and post-bariatric surgery on pulmonary function. Pooled effect estimates were calculated using random-effects model. Twenty-three studies with 1013 participants were included in the final meta-analysis. Only 8 studies had intervention and control groups with different time points, but 15 studies had matched groups with different time points. Overall, pulmonary function score was significantly improved after bariatric surgery, with a pooled standardized mean difference of .59 (95% confidence interval: .46-.73). Heterogeneity test was performed by using Cochran's Q test (I 2 = 46%; P heterogeneity = .10). Subgroup analysis and univariate meta-regression based on study quality, age, presurgery body mass index, postsurgery body mass index, study design, female patients only, study continent, asthmatic patients in the study, and the type of bariatric surgery confirmed no statistically significant difference among these groups (P value>.05 for all). A multivariate meta-regression model, which adjusted simultaneously for these same covariates, did not change the results (P value > .05 overall). Assessment of publication bias was done visually and by Begg's rank correlation test and indicated the absence of publication bias (asymmetric shape was observed and P = .34). This meta-analysis shows that bariatric surgery significantly improved overall pulmonary functions score for morbid obesity. Copyright © 2018 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.
Electrocardiographic screening for emphysema: the frontal plane P axis.
Baljepally, R; Spodick, D H
1999-03-01
Because the most characteristic and sensitive electrocardiographic (ECG) correlate of pulmonary emphysema in adults is verticalization of the frontal plane P-wave vector (P axis), we investigated its strength as a lone criterion to screen for obstructive pulmonary disease (OPD) in an adult hospital population. In all, 954 consecutive unselected ECGs were required to yield 100 with P axis > or = +70 degrees (unequivocally negative P in a VL during sinus rhythm) and pulmonary function tests. and 100 with P axis < or = +50 degrees (unequivocally positive P-aVL). Obstructive pulmonary disease by both pulmonary function test and clinical criteria was present in 89 of 100 patients with vertical P axes and 4 of 100 patients without OPD. The high sensitivity (89% for this series) and high specificity (96%) makes vertical P axis a useful screening criterion. Its at-a-glance simplicity makes it "user-friendly."
Takai, Daiya
2014-12-01
The symposium consisted of four parts: history of lung function tests, nitric oxide for diagnosis and monitoring of bronchial asthma, radiological and functional changes of the lung in COPD, and combined pulmonary fibrosis and emphysema (CPFE) occasionally showing almost normal results in lung function tests. The history of lung function tests was presented by Dr. Naoko Tojo of the Tokyo Medical and Dental University. Nitric oxide tests in clinical use for diagnosis and monitoring of bronchial asthma were presented by Dr. Hiroyuki Nagase of Teikyo University. Radiological and functional changes of the lung in COPD were presented by Dr. Shigeo Muro of Kyoto University. Clinical features of combined pulmonary fibrosis and emphysema and their associated lung function were presented by Dr. Daiya Takai of the University of Tokyo. I hope that discussing the history of lung function tests until the present was useful for many medical technologists. (Review).
Recent lung imaging studies. [Effectiveness for diagnosis of chronic obstructive pulmonary disease
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taplin, G.V.; Chopra, S.K.
1976-01-01
Radionuclide lung imaging procedures have been available for 11 years but only the perfusion examination has been used extensively and mainly for the diagnosis of pulmonary embolism (P.E.). Its ability to reveal localized ischemia makes it a valuable test of regional lung function as well as a useful diagnostic aid in P.E. Although it had been recognized for several years that chronic obstructive pulmonary disease (COPD) can cause lung perfusion defects which may simulate pulmonary embolism, relatively little use has been made of either the radioxenon or the radioaerosol inhalation lung imaging procedures until the last few years as amore » means of distinguishing P.E. from COPD. In this review emphasis is placed on our recent experience with both of these inhalation procedures in comparison with pulmonary function tests and roentgenography for the early detection of COPD in population studies. Equal emphasis is given to simultaneous aerosol ventilation-perfusion (V/P) imaging for a functional diagnosis of P.E. Two new developments in regional lung diffusion imaging, performed after the inhalation of radioactive gases and/or rapidly absorbed radioaerosols are described. The experimental basis for their potential clinical application in pulmonary embolism detection is presented.« less
Ikegami, Kazunori; Hasegawa, Masayuki; Ando, Hajime; Hata, Koichi; Kitamura, Hiroko; Ogami, Akira; Higashi, Toshiaki
2016-10-08
This study examines the acute and chronic respiratory effects of toner exposure based on markers for interstitial pneumonia, oxidative stress and pulmonary function tests. A total of 112 subjects working in a Japanese toner and photocopier manufacturing company participated in this study in 2004. We annually conducted personal exposure measurements, pulmonary function tests, chest X-ray examinations, biomarkers, and questionnaires on respiratory symptoms to the subjects. We report in this paper the results of the analysis of combined annual survey point data from 2004 to 2008 and data from three annual survey points, 2004, 2008, and 2013. During these survey periods, we observed that none of subjects had a new onset of respiratory disease or died of such a disease. In both the analyses, there were no significant differences in each biomarker and pulmonary function tests within the subjects, nor between a toner-handling group and a non-toner-handling group, except for a few results on pulmonary function tests. The findings of this study suggest that there were no acute and chronic respiratory effects of toner exposure in this cohort group, although the number of subjects was small and the level of toner exposure in this worksite was low.
IKEGAMI, Kazunori; HASEGAWA, Masayuki; ANDO, Hajime; HATA, Koichi; KITAMURA, Hiroko; OGAMI, Akira; HIGASHI, Toshiaki
2016-01-01
This study examines the acute and chronic respiratory effects of toner exposure based on markers for interstitial pneumonia, oxidative stress and pulmonary function tests. A total of 112 subjects working in a Japanese toner and photocopier manufacturing company participated in this study in 2004. We annually conducted personal exposure measurements, pulmonary function tests, chest X–ray examinations, biomarkers, and questionnaires on respiratory symptoms to the subjects. We report in this paper the results of the analysis of combined annual survey point data from 2004 to 2008 and data from three annual survey points, 2004, 2008, and 2013. During these survey periods, we observed that none of subjects had a new onset of respiratory disease or died of such a disease. In both the analyses, there were no significant differences in each biomarker and pulmonary function tests within the subjects, nor between a toner–handling group and a non–toner–handling group, except for a few results on pulmonary function tests. The findings of this study suggest that there were no acute and chronic respiratory effects of toner exposure in this cohort group, although the number of subjects was small and the level of toner exposure in this worksite was low. PMID:27021062
Computer-Based Techniques for Collection of Pulmonary Function Variables during Rest and Exercise.
1991-03-01
routinely Included in experimental protocols involving hyper- and hypobaric excursions. Unfortunately, the full potential of those tests Is often not...for a Pulmonary Function data acquisition system that has proven useful in the hyperbaric research laboratory. It illustrates how computers can
Manoharan, Sujatha C; Ramakrishnan, Swaminathan
2009-10-01
In this work, prediction of forced expiratory volume in pulmonary function test, carried out using spirometry and neural networks is presented. The pulmonary function data were recorded from volunteers using commercial available flow volume spirometer in standard acquisition protocol. The Radial Basis Function neural networks were used to predict forced expiratory volume in 1 s (FEV1) from the recorded flow volume curves. The optimal centres of the hidden layer of radial basis function were determined by k-means clustering algorithm. The performance of the neural network model was evaluated by computing their prediction error statistics of average value, standard deviation, root mean square and their correlation with the true data for normal, restrictive and obstructive cases. Results show that the adopted neural networks are capable of predicting FEV1 in both normal and abnormal cases. Prediction accuracy was more in obstructive abnormality when compared to restrictive cases. It appears that this method of assessment is useful in diagnosing the pulmonary abnormalities with incomplete data and data with poor recording.
Pulmonary function evaluation during the Skylab and Apollo-Soyuz missions.
Sawin, C F; Nicogossian, A E; Rummel, J A; Michel, E L
1976-02-01
Previous experience during Apollo postflight exercise testing indicated no major changes in pulmonary function. Pulmonary function has been studied in detail following exposure to hypoxic and hyperoxic normal gravity environments, but no previous study has reported on men exposed to an environment that was both normoxic at 258 torr total pressure and at null gravity as encountered in Skylab. Forced vital capacity (FVC) was measured during the preflight and postflight periods of the Skylab 2 mission. Inflight measurements of vital capacity (VC) were obtained during the last 2 weeks of the second manned mission (Skylab 3). More detailed pulmonary function screening was accomplished during the Skylab 4 mission. The primary measurements made during Skylab 4 testing included residual volume determination (RV), closing volume (CV), VC, FVC and its derivatives. In addition, VC was measured in flight at regular intervals during the Skylab 4 mission. Vital capacity was decreased slightly (-10%) in flight in all Skylab 4 crewmen. No major preflight-to-postflight changes were observed. The Apollo-Soyuz Test Project (ASTP) crewmen were studied using equipment and procedures similar to those employed during Skylab 4. Postflight evaluation of the ASTP crewmen was complicated by their inadvertent exposure to nitrogen tetroxide gas fumes upon reentry.
Pulmonary function evaluation during the Skylab and Apollo-Soyuz missions
NASA Technical Reports Server (NTRS)
Sawin, C. F.; Nicogossian, A. E.; Rummel, J. A.; Michel, E. L.
1976-01-01
Previous experience during Apollo postflight exercise testing indicated no major changes in pulmonary function. Pulmonary function has been studied in detail following exposure to hypoxic and hyperoxic normal gravity environments, but no previous study has reported on men exposed to an environment that was both normoxic at 258 torr total pressure and at null gravity as encountered in Skylab. Forced vital capacity (FVC) was measured during the preflight and postflight periods of the Skylab 2 mission. Inflight measurements of vital capacity (VC) were obtained during the last 2 weeks of the second manned mission (Skylab 3). More detailed pulmonary function screening was accomplished during the Skylab 4 mission. The primary measurements made during Skylab 4 testing included residual volume determination (RV), closing volume (CV), VC, FVC and its derivatives. In addition, VC was measured in flight at regular intervals during the Skylab 4 mission. Vital capacity was decreased slightly (-10%) in flight in all Skylab 4 crewmen. No major preflight-to-postflight changes were observed. The Apollo-Soyuz Test Project (ASTP) crewmen were studied using equipment and procedures similar to those employed during Skylab 4. Postflight evaluation of the ASTP crewmen was complicated by their inadvertent exposure to nitrogen tetroxide gas fumes upon reentry.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chinet, T.; Dusser, D.; Labrune, S.
1990-02-01
Respiratory epithelial clearance of {sup 99m}Tc-DTPA (RC-Tc-DTPA) and pulmonary function tests (PFT) were determined at intervals of 6 or 12 months in 37 untreated, nonsmoking patients with sarcoidosis over a period of 6 to 36 months. PFT included the measurements of total lung capacity (TLC), vital capacity (VC), FEV1, and diffusing capacity for carbon monoxide. No difference was found between the respiratory clearance of {sup 113m}In-DTPA (2.25 +/- 1.00%/min) and RC-Tc-DTPA (2.29 +/- 1.11%/min) in eight patients with pulmonary sarcoidosis. Pulmonary function decreased 15% or more in at least 2 function tests during 11 follow-up periods, but it remained stablemore » during 47 follow-up periods. In patients whose lung function deteriorated, RC-Tc-DTPA increased to 3.51 +/- 1.55%/min; in contrast, in patients whose lung function remained stable, regardless of the initial values, RC-Tc-DTPA was normal (1.00 +/- 0.50%/min; p less than 0.001). In eight patients who were treated with corticosteroids, RC-Tc-DTPA decreased from 3.48 +/- 1.31%/min to 1.56 +/- 0.64%/min (p less than 0.001), and PFT improved. We conclude that in nonsmokers with pulmonary sarcoidosis, increased RC-Tc-DTPA is not related to dissociation of 99mTc from DTPA, RC-Tc-DTPA is increased when pulmonary function decreases, and, when increased, RC-Tc-DTPA decreases with corticosteroid therapy.« less
20 CFR 725.406 - Medical examinations and tests.
Code of Federal Regulations, 2010 CFR
2010-04-01
... complete pulmonary evaluation includes a report of physical examination, a pulmonary function study, a chest roentgenogram and, unless medically contraindicated, a blood gas study. (b) As soon as possible... test authorized under this section, including the cost of travel to and from the examination, shall be...
[Normal lung volumes in patients with idiopathic pulmonary fibrosis and emphysema].
Casas, Juan Pablo; Abbona, Horacio; Robles, Adriana; López, Ana María
2008-01-01
Pulmonary function tests in idiopathic pulmonary fibrosis characteristically show a restrictive pattern, resulting from reduction of pulmonary compliance due to diffuse fibrosis. Conversely, an obstructive pattern with hyperinflation results in emphysema by loss of elastic recoil, expiratory collapse of the peripheral airways and air trapping. Previous reports suggest that when both diseases coexist, pulmonary volumes are compensated and a smaller than expected reduction or even normal lung volumes can be found. We report 4 male patients of 64, 60, 73 and 70 years, all with heavy cigarette smoking history and progressive breathlessness. Three of them had severe limitation in their quality of life. All four showed advanced lung interstitial involvement, at high resolution CT scan, fibrotic changes predominantly in the subpleural areas of lower lung fields and concomitant emphysema in the upper lobes. Emphysema and pulmonary fibrosis was confirmed by open lung biopsy in one patient. The four patients showed normal spirometry and lung volumes with severe compromise of gas exchange and poor exercise tolerance evaluated by 6 minute walk test. Severe pulmonary arterial hypertension was also confirmed in three patients. Normal lung volumes does not exclude diagnosis of idiopathic pulmonary fibrosis in patients with concomitant emphysema. The relatively preserved lung volumes may underestimate the severity of idiopathic pulmonary fibrosis and attenuate its effects on lung function parameters.
EFFECTS OF OZONE ON THE PULMONARY FUNCTION OF CHILDREN
Healthy active children, 7 to 13 years old, in a summer recreational camp were chosen as subjects to investigate the acute effects of exposure to ambient air pollution. Pulmonary function tests were administered at the camp on 16 days during a five week period in 1982. Ambient ai...
Yang, Xiaotian; Zhou, Yujing; Wang, Pu; He, Chengqi; He, Hongchen
2016-05-01
To examine the effect of whole-body vibration in enhancing pulmonary function, functional exercise capacity and quality of life in people with chronic obstructive pulmonary disease and examine its safety. Randomized controlled trials examining the effects of whole body vibration among people with chronic obstructive pulmonary disease were identified by two independent researchers. Articles were excluded if they were studies on people with other primary diagnosis, abstracts published in the conferences or books. PEDro scale was used to assess the methodological quality of the selected studies. We evaluated the level of evidence by using the GRADE approach. The results were extracted by two researchers and confirmed by the third researcher if disagreement existed. Sources included Cochrane Central Register of Controlled Trials, PubMed, CINAHL, EMBASE, PEDro, AMED, PsycINFO, ClinicalTrials.gov, Current Controlled Trials and reference lists of all relevant articles. Four studies involving 206 participants were included in this systematic review. Methodological quality was rated as good for two studies. No great benefits on pulmonary function were found in whole body vibration treatment group. Two studies showed that quality of life was improved in people with chronic obstructive pulmonary disease. Whole body vibration led to significant improvements in functional exercise capacity measured with six minutes walking test. Nearly no adverse events were observed. Whole body vibration may improve functional exercise capacity and quality of life in people with chronic obstructive pulmonary disease. There was insufficient evidence to prove the effects of whole body vibration on pulmonary function. © The Author(s) 2015.
Effects of physician counseling on the smoking behavior of asbestos-exposed workers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, V.C.; Kim, Y.J.; Ewart, C.K.
Physician antismoking advice has been shown to increase smoking cessation, particularly among patients who have medical problems or perceive themselves to be at risk. The present study tested three hypotheses: (a) providing 3 to 5 min of behavioral counseling regarding a cessation strategy would be more effective than simply warning the smoker to quit smoking; (b) smokers with abnormal pulmonary function would be more likely to comply with medical advice than would smokers with normal pulmonary function; and (c) that smokers with abnormal pulmonary function who receive behavioral counseling would be the group most likely to achieve prolonged abstinence. Asbestos-exposedmore » smoking men undergoing screening in a mandated program for naval shipyard workers were categorized as having normal or abnormal pulmonary status on the basis of chest X ray and pulmonary function tests (PFT). They were then randomly assigned within PFT categories to receive either a simple warning or 3 to 5 min of behavioral cessation counseling from the physician who gave them the results of their pulmonary tests. Subjects smoking status was evaluated at 3- and 11-month intervals following the physician intervention. Smokers who received behavioral counseling were more likely to quit and remain abstinent over the 11-month period (8.4% abstinent) than were smokers given a minimal warning (3.6% abstinent). Prolonged abstinence rates among abnormal PFT subjects (3.7%) did not differ from those of normals (5.9%). The group with normal PFT who received behavioral counseling achieved the highest level of abstinence (9.5%).« less
2016-01-01
Influenza vaccination is an effective strategy to reduce morbidity and mortality, particularly for those who have decreased lung functions. This study was to identify the factors that affect vaccination coverage according to the results of pulmonary function tests depending on the age. In this cross-sectional study, data were obtained from 3,224 adults over the age of 40 who participated in the fifth National Health and Nutrition Examination Survey and underwent pulmonary function testing in 2012. To identify the factors that affect vaccination rate, logistic regression analysis was conducted after dividing the subjects into two groups based on the age of 65. Influenza vaccination coverage of the entire subjects was 45.2%, and 76.8% for those aged 65 and over. The group with abnormal pulmonary function had a higher vaccination rate than the normal group, but any pulmonary dysfunction or history of COPD did not affect the vaccination coverage in the multivariate analysis. The subjects who were 40-64 years-old had higher vaccination coverage when they were less educated or with restricted activity level, received health screenings, and had chronic diseases. Those aged 65 and over had significantly higher vaccination coverage only when they received regular health screenings. Any pulmonary dysfunction or having COPD showed no significant correlation with the vaccination coverage in the Korean adult population. PMID:27134491
Hyperpolarized Gas MRI: Technique and Applications
McAdams, Holman P.; Kaushik, S. Sivaram; Driehuys, Bastiaan
2015-01-01
Synopsis Functional imaging today offers a rich world of information that is more sensitive to changes in lung structure and function than traditionally obtained pulmonary function tests. Hyperpolarized helium (3He) and xenon (129Xe) MR imaging of the lungs provided new sensitive contrast mechanisms to probe changes in pulmonary ventilation, microstructure and gas exchange. With the recent scarcity in the supply of 3He the field of hyperpolarized gas imaging shifted to the use of cheaper and naturally available 129Xe. Xenon is well tolerated and recent technical advances have ensured that the 129Xe image quality is on par with that of 3He. The added advantage of 129Xe is its solubility in pulmonary tissue, which allows exploring specific lung function characteristics involved in gas exchange and alveolar oxygenation. With a plethora of contrast mechanisms, hyperpolarized gases and 129Xe in particular, stands to be an excellent probe of pulmonary structure and function, and provide sensitive and non-invasive biomarkers for a wide variety of pulmonary diseases. PMID:25952516
Minakata, Yoshiaki; Morishita, Yukiko; Ichikawa, Tomohiro; Akamatsu, Keiichiro; Hirano, Tsunahiko; Nakanishi, Masanori; Matsunaga, Kazuto; Ichinose, Masakazu
2015-01-01
Improvement in the daily physical activity (PA) is important for the management of chronic obstructive pulmonary disease (COPD). However, the effects of pharmacologic treatment on PA are not well understood. We evaluated the effects of additional medications, including bronchodilator with or without inhaled corticosteroid, based on airflow limitation and breathlessness on the PA in COPD patients and the factors that could predict or affect the improvement in PA. A prospective non-randomized observational study was employed. Twenty-one COPD subjects without any other diseases that might reduce PA were recruited. The PA was measured with a triaxial accelerometer for 2 weeks, and pulmonary function tests and incremental shuttle walking tests were administered before and after 4-week treatment with an additional medication. Bronchodilation was obtained by additional medication. The mean values of PA evaluated by metabolic equivalents (METs) at ≥3.0 METs and the duration of PA at ≥3.0 METs and ≥3.5 METs were improved by medication. The % change in the duration of PA at ≥3.5 METs was significantly correlated with the baseline functional residual capacity (FRC), residual volume, and inspiratory capacity/total lung capacity. However, the % change in the duration of PA at any intensity was not correlated with the % changes of any values of the pulmonary function tests or incremental shuttle walking test except the PA at ≥2.5 METs with FRC. Medication could improve the PA in patients with COPD, especially at a relatively high intensity of activity when medication was administered based on airflow limitation and breathlessness. The improvement was seen in the patients with better baseline lung volume, but was not correlated with the improvements in the pulmonary function tests or exercise capacity.
[Functional respiratory evolution in two patients with emphysema and pulmonary fibrosis].
Arce, Santiago C; Molinari, Luciana; De Vito, Eduardo L
2009-01-01
Combined pulmonary fibrosis and emphysema (CPFE) is a frequently under-diagnosed condition. Isolated pulmonary function tests (PFT) can give rise to misinterpretations. We have found no reports on these patients' spirometric progression. We describe two cases of CPFE, showing long-term functional evolution to have a more accurate understanding of current spirometric values. The most relevant findings are: 1) spirometry with discrete functional alterations in the presence of a marked dyspnea and the need, in one patient, for chronic oxygen therapy; and 2) functional evolution reflecting "pseudonormalisation" of the initial obstructive spirometric pattern, possibly as a result of fibrosis development. A mild obstructive defect in a patient with chronic airflow limitation and marked impairment of his/her clinical status and functional class should alert on the possibility of associated pulmonary fibrosis. A computed tomography (CT) and previous PFTs will allow a better understanding of this condition.
Ambient polycyclic aromatic hydrocarbons and pulmonary function in children
Padula, Amy M.; Balmes, John R.; Eisen, Ellen A.; Mann, Jennifer; Noth, Elizabeth M.; Lurmann, Frederick W.; Pratt, Boriana; Tager, Ira B.; Nadeau, Kari; Hammond, S. Katharine
2014-01-01
Few studies have examined the relationship between ambient polycyclic aromatic hydrocarbons (PAHs) and pulmonary function in children. Major sources include vehicular emissions, home heating, wildland fires, agricultural burning, and power plants. PAHs are an important component of fine particulate matter that has been linked to respiratory health. This cross-sectional study examines the relationship between estimated individual exposures to the sum of PAHs with 4, 5, or 6 rings (PAH456) and pulmonary function tests (forced expiratory volume in one second (FEV1) and forced expiratory flow between 25% and 75% of vital capacity) in asthmatic and non-asthmatic children. We applied land-use regression to estimate individual exposures to ambient PAHs for averaging periods ranging from 1 week to 1 year. We used linear regression to estimate the relationship between exposure to PAH456 with pre- and postbronchodilator pulmonary function tests in children in Fresno, California (N =297). Among non-asthmatics, there was a statistically significant association between PAH456 during the previous 3 months, 6 months, and 1 year and postbronchodilator FEV1. The magnitude of the association increased with the length of the averaging period ranging from 60 to 110 ml decrease in FEV1 for each 1 ng/m3 increase in PAH456. There were no associations with PAH456 observed among asthmatic children. We identified an association between annual PAHs and chronic pulmonary function in children without asthma. Additional studies are needed to further explore the association between exposure to PAHs and pulmonary function, especially with regard to differential effects between asthmatic and non-asthmatic children. PMID:24938508
Treatment of idiopathic pulmonary fibrosis with losartan: a pilot project.
Couluris, Marisa; Kinder, Brent W; Xu, Ping; Gross-King, Margaret; Krischer, Jeffrey; Panos, Ralph J
2012-10-01
Idiopathic pulmonary fibrosis is a progressive interstitial lung disease with no current effective therapies. Treatment has focused on antifibrotic agents to stop proliferation of fibroblasts and collagen deposition in the lung. We present the first clinical trial data on the use of losartan, an antifibrotic agent, to treat idiopathic pulmonary fibrosis. The primary objective was to evaluate the effect of losartan on progression of idiopathic pulmonary fibrosis measured by the change in percentage of predicted forced vital capacity (%FVC) after 12 months. Secondary outcomes included the change in forced expiratory volume at 1 second, diffusing capacity of carbon monoxide, 6-minute walk test distance, and baseline/transition dyspnea index. Patients with idiopathic pulmonary fibrosis and a baseline %FVC of ≥50 % were treated with losartan 50 mg by mouth daily for 12 months. Pulmonary function testing, 6-minute walk, and breathlessness indices were measured every 3 months. Twenty participants with idiopathic pulmonary fibrosis were enrolled and 17 patients were evaluable for response. Twelve patients had a stable or improved %FVC at study month 12. Similar findings were observed in secondary end-point measures, including 58, 71, and 65 % of patients with stable or improved forced expiratory volume at 1 second, diffusing capacity for carbon monoxide, and 6-minute walk test distance, respectively. No treatment-related adverse events that resulted in early study discontinuation were reported. Losartan stabilized lung function in patients with idiopathic pulmonary fibrosis over 12 months. Losartan is a promising agent for the treatment of idiopathic pulmonary fibrosis and has a low toxicity profile.
Decrease in pulmonary function and oxygenation after lung resection
Westerdahl, Elisabeth; Langer, Daniel; Souza, Domingos S.R.; Andreasen, Jan Jesper
2018-01-01
Respiratory deficits are common following curative intent lung cancer surgery and may reduce the patient's ability to be physically active. We evaluated the influence of surgery on pulmonary function, respiratory muscle strength and physical performance after lung resection. Pulmonary function, respiratory muscle strength (maximal inspiratory/expiratory pressure) and 6-min walk test (6MWT) were assessed pre-operatively, 2 weeks post-operatively and 6 months post-operatively in 80 patients (age 68±9 years). Video-assisted thoracoscopic surgery was performed in 58% of cases. Two weeks post-operatively, we found a significant decline in pulmonary function (forced vital capacity −0.6±0.6 L and forced expiratory volume in 1 s −0.43±0.4 L; both p<0.0001), 6MWT (−37.6±74.8 m; p<0.0001) and oxygenation (−2.9±4.7 units; p<0.001), while maximal inspiratory and maximal expiratory pressure were unaffected. At 6 months post-operatively, pulmonary function and oxygenation remained significantly decreased (p<0.001), whereas 6MWT was recovered. We conclude that lung resection has a significant short- and long-term impact on pulmonary function and oxygenation, but not on respiratory muscle strength. Future research should focus on mechanisms negatively influencing post-operative pulmonary function other than impaired respiratory muscle strength. PMID:29362707
Decrease in pulmonary function and oxygenation after lung resection.
Brocki, Barbara Cristina; Westerdahl, Elisabeth; Langer, Daniel; Souza, Domingos S R; Andreasen, Jan Jesper
2018-01-01
Respiratory deficits are common following curative intent lung cancer surgery and may reduce the patient's ability to be physically active. We evaluated the influence of surgery on pulmonary function, respiratory muscle strength and physical performance after lung resection. Pulmonary function, respiratory muscle strength (maximal inspiratory/expiratory pressure) and 6-min walk test (6MWT) were assessed pre-operatively, 2 weeks post-operatively and 6 months post-operatively in 80 patients (age 68±9 years). Video-assisted thoracoscopic surgery was performed in 58% of cases. Two weeks post-operatively, we found a significant decline in pulmonary function (forced vital capacity -0.6±0.6 L and forced expiratory volume in 1 s -0.43±0.4 L; both p<0.0001), 6MWT (-37.6±74.8 m; p<0.0001) and oxygenation (-2.9±4.7 units; p<0.001), while maximal inspiratory and maximal expiratory pressure were unaffected. At 6 months post-operatively, pulmonary function and oxygenation remained significantly decreased (p<0.001), whereas 6MWT was recovered. We conclude that lung resection has a significant short- and long-term impact on pulmonary function and oxygenation, but not on respiratory muscle strength. Future research should focus on mechanisms negatively influencing post-operative pulmonary function other than impaired respiratory muscle strength.
Doyle, Todd; Palmer, Scott; Johnson, Julie; Babyak, Michael A.; Smith, Patrick; Mabe, Stephanie; Welty-Wolf, Karen; Martinu, Tereza; Blumenthal, James A.
2014-01-01
Objectives To examine the association of anxiety and depression with pulmonary-specific symptoms of Chronic Obstructive Pulmonary Disease (COPD), and to determine the extent to which disease severity and functional capacity modify this association. Method Patients (N = 162) enrolled in the INSPIRE-II study, an ongoing randomized, clinical trial of COPD patients and their caregivers who received either telephone-based coping skills training or education and symptom monitoring. Patients completed a psychosocial test battery including: Brief Fatigue Inventory, St. George’s Respiratory Questionnaire, UCSD Shortness of Breath Questionnaire, State-Trait Anxiety Inventory, and Beck Depression Inventory. Measures of disease severity and functional capacity (i.e., FEV1 and six-minute walk test) were also obtained. Results After covariate adjustment, higher anxiety and depression levels were associated with greater fatigue levels (ps < .001, ΔR2 = 0.16 and 0.29, respectively), shortness of breath (ps < .001, ΔR2 = 0.12 and 0.10), and frequency of COPD symptoms (ps < .001, ΔR2 = 0.11 and 0.13). In addition, functional capacity was a moderator of anxiety and pulmonary-specific COPD symptoms. The association between anxiety and shortness of breath (p = 0.009) and frequency of COPD symptoms (p = 0.02) was greater among patients with lower functional capacity. Conclusions Anxiety and depression were associated with higher levels of fatigue, shortness of breath, and frequency of COPD symptoms. It is important for clinicians to be aware of the presence of anxiety and depression in COPD patients, which appears to correlate with pulmonary-specific COPD symptoms, especially in patients with lower functional capacity. Prospective design studies are needed to elucidate the causal relationships between anxiety and depression and pulmonary-specific symptoms in COPD patients. PMID:23977821
Efficacy and safety of chloral hydrate sedation in infants for pulmonary function tests.
Wandalsen, Gustavo Falbo; Lanza, Fernanda de Cordoba; Nogueira, Márcia Cristina Pires; Solé, Dirceu
2016-12-01
To describe the efficacy and safety of chloral hydrate sedation in infants for pulmonary function tests. All sedation attempts for pulmonary function tests in infants carried out between June 2007 and August 2014 were evaluated. Obstructive sleep apnea and heart disease were contraindications to the exams. Anthropometric data, exam indication, used dose, outcomes of sedation and clinical events were recorded and described. The sedation attempts in 277 infants (165 boys) with a median age of 51.5 weeks of life (14 to 182 weeks) were evaluated. The main indication for the tests was recurrent wheezing (56%) and the chloral hydrate dose ranged from 50 to 80mg/kg (orally). Eighteen (6.5%) infants had some type of clinical complication, with the most frequent being cough and/or airway secretion (1.8%); respiratory distress (1.4%) and vomiting (1.1%). A preterm infant had bradycardia for approximately 15 minutes, which was responsive to tactile stimulation. All observed adverse effects were transient and there was no need for resuscitation or use of injectable medications. The data demonstrated that chloral hydrate at the employed doses is a safe and effective medicament for sedation during short procedures in infants, such as pulmonary function tests. Because of the possibility of severe adverse events, recommendations on doses and contraindications should be strictly followed and infants should be monitored by trained staff. Copyright © 2016 Sociedade de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.
Pulmonary function in children with development coordination disorder.
Wu, Sheng K; Cairney, John; Lin, Hsiao-Hui; Li, Yao-Chuen; Song, Tai-Fen
2011-01-01
The purpose of this study was to compare pulmonary function in children with developmental coordination disorder (DCD) with children who are typically developing (TD), and also analyze possible gender differences in pulmonary function between these groups. The Movement ABC test was used to identify the movement coordination ability of children. Two hundred and fifty participants (90 children with DCD and 160 TD children) aged 9-10 years old completed this study. Using the KoKo spirometry, forced vital capacity (FVC) and forced expiratory volume in 1s (FEV(1.0)) were used to measure pulmonary function. The 800-m run was also conducted to assess cardiopulmonary fitness of children in the field. There was a significant difference in pulmonary function between TD children and those with DCD. The values of FVC and FEV(1.0) in TD children were significantly higher than in children with DCD. A significant, but low correlation (r = -0.220, p < .001) was found between total score on the MABC and FVC; similarly, a positive but low correlation (r = 0.252, p < .001) was found between total score on the MABC and the completion time of 800-m run. However, no significant correlation between FVC and the time of 800-m run was found (p > .05). Significant correlations between total score on the MABC and the completion time of the 800-m run (r = 0.352, p < .05) and between FVC and the time of 800-m run (r = -0.285, p < .05) were observed in girls with DCD but not boys with this condition. Based on the results of this study, pulmonary function in children with DCD was significantly lower than that of TD children. The field test, 800-m run, may not be a good indicator to distinguish aerobic ability between children with DCD and those who are TD. It is possible that poor pulmonary function in children with DCD is due to reduced physical activity in this population. Copyright © 2010 Elsevier Ltd. All rights reserved.
Secondary Pulmonary Hypertension and Right-Sided Heart Failure at Presentation in Grave's Disease.
Ganeshpure, Swapnil Panjabrao; Vaidya, Gaurang Nandkishor; Gattani, Vipul
2012-01-01
A young female presented with evidence of right-sided heart failure and was subsequently found to have significant pulmonary artery hypertension (PAH). Because of her normal left ventricular function and pulmonary capillary wedge pressure, the most probable site of etiology seemed to be the pulmonary vasculature. All the common possible secondary causes of PAH were ruled out, but during the investigations, she was found to have elevated thyroid function tests compatible with the diagnosis of Grave's disease. The treatment of Grave's disease, initially by medications and subsequently by radioiodine therapy, was associated with a significant reduction in the pulmonary artery systolic pressure. The purpose of this case report is to highlight one of the unusual and underdiagnosed presentations of Grave's disease.
Genome-wide association and large scale follow-up identifies 16 new loci influencing lung function
Artigas, María Soler; Loth, Daan W; Wain, Louise V; Gharib, Sina A; Obeidat, Ma’en; Tang, Wenbo; Zhai, Guangju; Zhao, Jing Hua; Smith, Albert Vernon; Huffman, Jennifer E; Albrecht, Eva; Jackson, Catherine M; Evans, David M; Cadby, Gemma; Fornage, Myriam; Manichaikul, Ani; Lopez, Lorna M; Johnson, Toby; Aldrich, Melinda C; Aspelund, Thor; Barroso, Inês; Campbell, Harry; Cassano, Patricia A; Couper, David J; Eiriksdottir, Gudny; Franceschini, Nora; Garcia, Melissa; Gieger, Christian; Gislason, Gauti Kjartan; Grkovic, Ivica; Hammond, Christopher J; Hancock, Dana B; Harris, Tamara B; Ramasamy, Adaikalavan; Heckbert, Susan R; Heliövaara, Markku; Homuth, Georg; Hysi, Pirro G; James, Alan L; Jankovic, Stipan; Joubert, Bonnie R; Karrasch, Stefan; Klopp, Norman; Koch, Beate; Kritchevsky, Stephen B; Launer, Lenore J; Liu, Yongmei; Loehr, Laura R; Lohman, Kurt; Loos, Ruth JF; Lumley, Thomas; Al Balushi, Khalid A; Ang, Wei Q; Barr, R Graham; Beilby, John; Blakey, John D; Boban, Mladen; Boraska, Vesna; Brisman, Jonas; Britton, John R; Brusselle, Guy G; Cooper, Cyrus; Curjuric, Ivan; Dahgam, Santosh; Deary, Ian J; Ebrahim, Shah; Eijgelsheim, Mark; Francks, Clyde; Gaysina, Darya; Granell, Raquel; Gu, Xiangjun; Hankinson, John L; Hardy, Rebecca; Harris, Sarah E; Henderson, John; Henry, Amanda; Hingorani, Aroon D; Hofman, Albert; Holt, Patrick G; Hui, Jennie; Hunter, Michael L; Imboden, Medea; Jameson, Karen A; Kerr, Shona M; Kolcic, Ivana; Kronenberg, Florian; Liu, Jason Z; Marchini, Jonathan; McKeever, Tricia; Morris, Andrew D; Olin, Anna-Carin; Porteous, David J; Postma, Dirkje S; Rich, Stephen S; Ring, Susan M; Rivadeneira, Fernando; Rochat, Thierry; Sayer, Avan Aihie; Sayers, Ian; Sly, Peter D; Smith, George Davey; Sood, Akshay; Starr, John M; Uitterlinden, André G; Vonk, Judith M; Wannamethee, S Goya; Whincup, Peter H; Wijmenga, Cisca; Williams, O Dale; Wong, Andrew; Mangino, Massimo; Marciante, Kristin D; McArdle, Wendy L; Meibohm, Bernd; Morrison, Alanna C; North, Kari E; Omenaas, Ernst; Palmer, Lyle J; Pietiläinen, Kirsi H; Pin, Isabelle; Polašek, Ozren; Pouta, Anneli; Psaty, Bruce M; Hartikainen, Anna-Liisa; Rantanen, Taina; Ripatti, Samuli; Rotter, Jerome I; Rudan, Igor; Rudnicka, Alicja R; Schulz, Holger; Shin, So-Youn; Spector, Tim D; Surakka, Ida; Vitart, Veronique; Völzke, Henry; Wareham, Nicholas J; Warrington, Nicole M; Wichmann, H-Erich; Wild, Sarah H; Wilk, Jemma B; Wjst, Matthias; Wright, Alan F; Zgaga, Lina; Zemunik, Tatijana; Pennell, Craig E; Nyberg, Fredrik; Kuh, Diana; Holloway, John W; Boezen, H Marike; Lawlor, Debbie A; Morris, Richard W; Probst-Hensch, Nicole; Kaprio, Jaakko; Wilson, James F; Hayward, Caroline; Kähönen, Mika; Heinrich, Joachim; Musk, Arthur W; Jarvis, Deborah L; Gläser, Sven; Järvelin, Marjo-Riitta; Stricker, Bruno H Ch; Elliott, Paul; O’Connor, George T; Strachan, David P; London, Stephanie J; Hall, Ian P; Gudnason, Vilmundur; Tobin, Martin D
2011-01-01
Pulmonary function measures reflect respiratory health and predict mortality, and are used in the diagnosis of chronic obstructive pulmonary disease (COPD). We tested genome-wide association with the forced expiratory volume in 1 second (FEV1) and the ratio of FEV1 to forced vital capacity (FVC) in 48,201 individuals of European ancestry, with follow-up of top associations in up to an additional 46,411 individuals. We identified new regions showing association (combined P<5×10−8) with pulmonary function, in or near MFAP2, TGFB2, HDAC4, RARB, MECOM (EVI1), SPATA9, ARMC2, NCR3, ZKSCAN3, CDC123, C10orf11, LRP1, CCDC38, MMP15, CFDP1, and KCNE2. Identification of these 16 new loci may provide insight into the molecular mechanisms regulating pulmonary function and into molecular targets for future therapy to alleviate reduced lung function. PMID:21946350
Text data extraction for a prospective, research-focused data mart: implementation and validation
2012-01-01
Background Translational research typically requires data abstracted from medical records as well as data collected specifically for research. Unfortunately, many data within electronic health records are represented as text that is not amenable to aggregation for analyses. We present a scalable open source SQL Server Integration Services package, called Regextractor, for including regular expression parsers into a classic extract, transform, and load workflow. We have used Regextractor to abstract discrete data from textual reports from a number of ‘machine generated’ sources. To validate this package, we created a pulmonary function test data mart and analyzed the quality of the data mart versus manual chart review. Methods Eleven variables from pulmonary function tests performed closest to the initial clinical evaluation date were studied for 100 randomly selected subjects with scleroderma. One research assistant manually reviewed, abstracted, and entered relevant data into a database. Correlation with data obtained from the automated pulmonary function test data mart within the Northwestern Medical Enterprise Data Warehouse was determined. Results There was a near perfect (99.5%) agreement between results generated from the Regextractor package and those obtained via manual chart abstraction. The pulmonary function test data mart has been used subsequently to monitor disease progression of patients in the Northwestern Scleroderma Registry. In addition to the pulmonary function test example presented in this manuscript, the Regextractor package has been used to create cardiac catheterization and echocardiography data marts. The Regextractor package was released as open source software in October 2009 and has been downloaded 552 times as of 6/1/2012. Conclusions Collaboration between clinical researchers and biomedical informatics experts enabled the development and validation of a tool (Regextractor) to parse, abstract and assemble structured data from text data contained in the electronic health record. Regextractor has been successfully used to create additional data marts in other medical domains and is available to the public. PMID:22970696
Text data extraction for a prospective, research-focused data mart: implementation and validation.
Hinchcliff, Monique; Just, Eric; Podlusky, Sofia; Varga, John; Chang, Rowland W; Kibbe, Warren A
2012-09-13
Translational research typically requires data abstracted from medical records as well as data collected specifically for research. Unfortunately, many data within electronic health records are represented as text that is not amenable to aggregation for analyses. We present a scalable open source SQL Server Integration Services package, called Regextractor, for including regular expression parsers into a classic extract, transform, and load workflow. We have used Regextractor to abstract discrete data from textual reports from a number of 'machine generated' sources. To validate this package, we created a pulmonary function test data mart and analyzed the quality of the data mart versus manual chart review. Eleven variables from pulmonary function tests performed closest to the initial clinical evaluation date were studied for 100 randomly selected subjects with scleroderma. One research assistant manually reviewed, abstracted, and entered relevant data into a database. Correlation with data obtained from the automated pulmonary function test data mart within the Northwestern Medical Enterprise Data Warehouse was determined. There was a near perfect (99.5%) agreement between results generated from the Regextractor package and those obtained via manual chart abstraction. The pulmonary function test data mart has been used subsequently to monitor disease progression of patients in the Northwestern Scleroderma Registry. In addition to the pulmonary function test example presented in this manuscript, the Regextractor package has been used to create cardiac catheterization and echocardiography data marts. The Regextractor package was released as open source software in October 2009 and has been downloaded 552 times as of 6/1/2012. Collaboration between clinical researchers and biomedical informatics experts enabled the development and validation of a tool (Regextractor) to parse, abstract and assemble structured data from text data contained in the electronic health record. Regextractor has been successfully used to create additional data marts in other medical domains and is available to the public.
Clinical pulmonary function and industrial respirator wear
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raven, P.B.; Moss, R.F.; Page, K.
1981-12-01
This investigation was the initial step in determining a clinical pulmonary test which could be used to evaluate workers as to their suitability to industrial respirator wear. Sixty subjects, 12 superior, 37 normal, and 11 moderately impaired with respect to lung function tests were evaluated with a battery of clinical pulmonary tests while wearing an industrial respirator. The respirator was a full-face mask (MSA-Ultravue) demand breathing type equipped with an inspiratory resistance of 85mm H/sub 2/O at 85 L/min air flow and an expiratory resistance of 25mm H/sub 2/O at 85 L/min air flow. Comparisons of these tests were mademore » between the three groups of subjects both with and without a respirator. It appears that those lung tests which measure the flow characteristics of the lung especially those that are effort dependant are more susceptible to change as a result of respirator wear. Hence, the respirator affects the person with superior lung function to a greater degree than the moderately impaired person. It was suggested that the clinical test of 15 second maximum voluntary ventilations (MVV./sub 25/) may be the test of choice for determining worker capability in wearing an industrial respirator.« less
Pulmonary functions in plastic factory workers: a preliminary study.
Khaliq, Farah; Singh, Pawan; Chandra, Prakash; Gupta, Keshav; Vaney, Neelam
2011-01-01
Exposure to long term air pollution in the work environment may result in decreased lung functions and various other health problems. A significant occupational hazard to lung functions is experienced by plastic factory workers. The present study is planned to assess the pulmonary functions of workers in the plastic factory where recycling of pastic material was done. These workers were constantly exposed to fumes of various chemicals throughout the day. Thirty one workers of plastic factory were assessed for their pulmonary functions. Parameters were compared with 31 age and sex matched controls not exposed to the same environment. The pulmonary function tests were done using Sibelmed Datospir 120 B portable spirometer. A significant decrease in most of the flow rates (MEF 25%, MEF 50%, MEF 75% and FEF 25-75%) and most of the lung volumes and capacities (FVC, FEV1, VC, TV, ERV, MVV) were observed in the workers. Smoking and duration of exposure were not affecting the lung functions as the non smokers also showed a similar decrement in pulmonary functions. Similarly the workers working for less than 5 years also had decrement in pulmonary functions indicating that their lungs are being affected even if they have worked for one year. Exposure to the organic dust in the work environment should be controlled by adequate engineering measures, complemented by effective personal respiratory protection.
HEALTH SIGNIFICANCE OF PULMONARY FUNCTION TESTS
As the sensitivity and precision of functional tests improves, we become increasingly able to measure responses to pollutant exposures with little, if any, demonstrable health significance. Proper interpretation of such functional responses generally requires an ability to evalua...
[A rare form of obstructive pulmonary disease].
van Loenhout, C J; den Bakker, M A; van Wijsenbeek, M S; Hoek, R A S; van Hal, P Th W
2016-01-01
Lymphangioleiomyomatosis (LAM) is characterised by progressive dyspnoea, spontaneous pneumothorax and cystic pulmonary destruction. The disease may show similarities with emphysema clinically, radiologically and on lung function tests. A 44-year-old woman was referred for lung transplantation because of a 6-year history of dyspnoea and severe obstructive pulmonary function disorder with decreased diffusion capacity. Both her relatively young age and the fact that she had never smoked made us doubt the diagnosis 'COPD'. The pulmonary cysts seen on high-resolution CT (HRCT) suggested LAM. This was confirmed when we revised a pulmonary biopsy that had previously been performed. CT investigation should be carried out in patients with severe obstructive pulmonary disease without a risk profile appropriate for COPD. Diffuse, homogenous cysts on CT scan can indicate LAM, particularly in women. Conflict of interest and financial support: none declared.
Impact of Pulmonary Artery Pressure on Exercise Function in Severe COPD
Sims, Michael W.; Margolis, David J.; Localio, A. Russell; Panettieri, Reynold A.; Kawut, Steven M.; Christie, Jason D.
2009-01-01
Background: Although pulmonary hypertension commonly complicates COPD, the functional consequences of increased pulmonary artery pressures in patients with this condition remain poorly defined. Methods: We conducted a cross-sectional analysis of a cohort of 362 patients with severe COPD who were evaluated for lung transplantation. Patients with pulmonary hemodynamics measured by cardiac catheterization and available 6-min walk test results were included. The association of mean pulmonary artery pressure (mPAP) with pulmonary function, echocardiographic variables, and 6-min walk distance was assessed. Results: The prevalence of pulmonary hypertension (mPAP, > 25 mm Hg; pulmonary artery occlusion pressure [PAOP], < 16 mm Hg) was 23% (95% confidence interval, 19 to 27%). In bivariate analysis, higher mPAP was associated with lower FVC and FEV1, higher Pco2 and lower Po2 in arterial blood, and more right heart dysfunction. Multivariate analysis demonstrated that higher mPAP was associated with shorter distance walked in 6 min, even after adjustment for age, gender, race, height, weight, FEV1, and PAOP (−11 m for every 5 mm Hg rise in mPAP; 95% confidence interval, −21 to −0.7; p = 0.04). Conclusions: Higher pulmonary artery pressures are associated with reduced exercise function in patients with severe COPD, even after controlling for demographics, anthropomorphics, severity of airflow obstruction, and PAOP. Whether treatments aimed at lowering pulmonary artery pressures may improve clinical outcomes in COPD, however, remains unknown. PMID:19318664
Lavoue, S; Le Gac, G; Gacouin, A; Revest, M; Sohier, L; Mouline, J; Jouneau, S; Flecher, E; Tattevin, P; Tadié, J-M
2016-09-01
To describe two cases of Panton-Valentine leukocidin-producing Staphylococcus aureus (PVL-SA) necrotizing pneumonia treated with ECMO, and complete pulmonary evaluation at six months. Retrospective analysis of two patients presenting with severe PVL-SA pneumonia who both underwent complete respiratory function testing and chest CT scan six months after hospital discharge. Indications for ECMO were refractory hypoxia and left ventricular dysfunction associated with right ventricular dilatation. Patients were weaned off ECMO after 52 and 5 days. No ECMO-related hemorrhagic complication was observed. Pulmonary function tests performed at six months were normal and the CT scan showed complete regression of pulmonary injuries. PVL-SA pneumonia is characterized by extensive parenchymal injuries, including necrotic and hemorrhagic complications. ECMO may be used as a salvage treatment without any associated hemorrhagic complication, provided anticoagulant therapy is carefully monitored, and may lead to complete pulmonary recovery at six months. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Ateş, Oğuz; Karakuş, Osman Z; Hakgüder, Gülce; Olguner, Mustafa; Akgür, Feza M
2013-09-01
The treatment of pectus carinatum (PC) deformity has been considered to be operative. Some authors have shown that postoperative pulmonary function is worsened. They have suggested that compromised chest wall expansion secondary to surgery leads to compromised pulmonary function. Several authors have advocated an orthotic brace for the treatment of PC. Pulmonary functions after orthotic brace treatment have not been investigated. Between April 2006 and October 2012, 61 patients presented with PC. Orthotic braces allowing gradual compression were prepared according to the anthropometric measurements of individual patients. The brace belt was tightened gradually. The brace was worn 6 h a day during the first week and the bracing time was prolonged for an additional hour per week till 16 h per day has been reached. Pre- and post-treatment echocardiography, pulmonary function tests and thorax computed tomography (CT) were obtained. The pectus severity index (Haller index) and the angle of sternal rotation were measured using CT. Satisfaction from bracing was evaluated by parents or patients at the end of the treatment. While the mean pretreatment Haller index was 1.96 ± 0.24, the mean post-treatment index was 2.26 ± 0.32. The angle of rotation was improved by 47.5%. Forced vital capacity and forced expiratory volume in 1 second were correlated with the predicted values for age. There was no statistically significant difference between pre- and post-treatment values. No skin breakdown or bruising was encountered. The overall average satisfaction score was 3.92 ± 0.27. We conclude that pulmonary function tests are not affected after brace treatment and gradual progression of bracing increases the patient's compliance.
Chlumský, J; Filipova, P; Terl, M
2006-01-01
Most patients with chronic obstructive pulmonary disease (COPD) have impaired respiratory muscle function. Maximal oesophageal pressure correlates closely with exercise tolerance and seems to predict the distance walked during the 6-min walk test. This study assessed the non-invasive parameters of respiratory muscle function in 41 patients with COPD to investigate their relationship to pulmonary function tests and exercise tolerance. The COPD patients, who demonstrated the full range of airway obstruction severity, had a mean forced expiratory volume in 1 s of 42.5% predicted (range, 20 - 79% predicted). Both the maximal inspiratory muscle strength and non-invasive tension-time index were significantly correlated with the degree of lung hyperinflation, as expressed by the ratio of residual volume to total lung capacity, and the distance walked in 6 min. We conclude that respiratory muscle function was influenced mainly by lung hyperinflation and that it had an important effect on exercise tolerance in COPD patients.
Sarcoidosis in children: HRCT findings and correlation with pulmonary function tests.
Sileo, C; Epaud, R; Mahloul, M; Beydon, N; Elia, D; Clement, A; Le Pointe, H Ducou
2014-12-01
High-resolution computed tomography (HRCT) plays an important role in the diagnosis and staging of pulmonary sarcoidosis, but implies radiation exposure. In this light, we aimed to describe HRCT findings as well as their relationship with pulmonary function tests (PFT) in children with pulmonary sarcoidosis. In a retrospective study, 18 pediatric patients with sarcoidosis, including 12 with pulmonary abnormalities (PA group) and 6 without pulmonary abnormalities (APA group) were followed over a 16-year period. Relationships between HRCT scores and PFT were studied by non-parametric Spearman's test at diagnosis and by restricted maximum likelihood (REML) analysis during follow-up. Forty-three HRCT were scored. Twelve patients showed abnormal HRCT findings at diagnosis with multiple nodules or micronodules, while ground-glass opacities were seen in 11 patients. Ten patients exhibited pleural thickening or thickening of the fissure and 6 had interlobular septal thickening at diagnosis. No correlation between HRCT and forced vital capacity (FVC), forced expiratory volume in 1 sec (FEV1), forced expiratory flow during the mid-half of the FVC (FEF(25-75)) and specific dynamical compliance (SpecC(Ldyn)) was found at diagnosis. However, linear mixed models showed that changes in total HRCT scores over time were significantly associated with SpecC(Ldyn), FVC, and FEV1 modifications. Radiologic findings in children with pulmonary sarcoidosis were similar to those in adults. HRCT and PFT are both essential investigations at diagnosis; however, the correlation between HRCT pulmonary parenchymal findings and PFT over time suggests the possibility of reducing the number of HRCT during follow-up to decrease unnecessary radiation exposure. © 2013 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krzyzanowski, M.; Sherrill, D.L.; Paoletti, P.
The data from consecutive surveys of the Tucson Epidemiologic Study (1981-1988) were used to evaluate the relationship in cigarette smokers of respiratory symptoms and pulmonary function to tar, nicotine, and carbon monoxide (CO) yields of the cigarette. There were 690 subjects who reported smoking regularly in at least one survey, over age 15. After adjustment for intensity and duration of smoking and for depth of inhalation, the risk of chronic phlegm, cough, and dyspnea were not related to the tar and nicotine yields. In 414 subjects with pulmonary function tested in at least one of the three surveys the spirometricmore » indices used were significantly related to the daily dose of tar, nicotine, and CO (product of the cigarette yield and daily number of cigarettes smoked). The effects were more pronounced for past than for current doses. However, the differentiation of pulmonary function due to various yields of cigarettes was small in comparison to the difference in pulmonary function between smokers and nonsmokers.« less
Automated lung sound analysis for detecting pulmonary abnormalities.
Datta, Shreyasi; Dutta Choudhury, Anirban; Deshpande, Parijat; Bhattacharya, Sakyajit; Pal, Arpan
2017-07-01
Identification of pulmonary diseases comprises of accurate auscultation as well as elaborate and expensive pulmonary function tests. Prior arts have shown that pulmonary diseases lead to abnormal lung sounds such as wheezes and crackles. This paper introduces novel spectral and spectrogram features, which are further refined by Maximal Information Coefficient, leading to the classification of healthy and abnormal lung sounds. A balanced lung sound dataset, consisting of publicly available data and data collected with a low-cost in-house digital stethoscope are used. The performance of the classifier is validated over several randomly selected non-overlapping training and validation samples and tested on separate subjects for two separate test cases: (a) overlapping and (b) non-overlapping data sources in training and testing. The results reveal that the proposed method sustains an accuracy of 80% even for non-overlapping data sources in training and testing.
Prins, Kurt W; Tian, Lian; Wu, Danchen; Thenappan, Thenappan; Metzger, Joseph M; Archer, Stephen L
2017-05-31
Pulmonary arterial hypertension (PAH) is a lethal disease characterized by obstructive pulmonary vascular remodeling and right ventricular (RV) dysfunction. Although RV function predicts outcomes in PAH, mechanisms of RV dysfunction are poorly understood, and RV-targeted therapies are lacking. We hypothesized that in PAH, abnormal microtubular structure in RV cardiomyocytes impairs RV function by reducing junctophilin-2 (JPH2) expression, resulting in t-tubule derangements. Conversely, we assessed whether colchicine, a microtubule-depolymerizing agent, could increase JPH2 expression and enhance RV function in monocrotaline-induced PAH. Immunoblots, confocal microscopy, echocardiography, cardiac catheterization, and treadmill testing were used to examine colchicine's (0.5 mg/kg 3 times/week) effects on pulmonary hemodynamics, RV function, and functional capacity. Rats were treated with saline (n=28) or colchicine (n=24) for 3 weeks, beginning 1 week after monocrotaline (60 mg/kg, subcutaneous). In the monocrotaline RV, but not the left ventricle, microtubule density is increased, and JPH2 expression is reduced, with loss of t-tubule localization and t-tubule disarray. Colchicine reduces microtubule density, increases JPH2 expression, and improves t-tubule morphology in RV cardiomyocytes. Colchicine therapy diminishes RV hypertrophy, improves RV function, and enhances RV-pulmonary artery coupling. Colchicine reduces small pulmonary arteriolar thickness and improves pulmonary hemodynamics. Finally, colchicine increases exercise capacity. Monocrotaline-induced PAH causes RV-specific derangement of microtubules marked by reduction in JPH2 and t-tubule disarray. Colchicine reduces microtubule density, increases JPH2 expression, and improves both t-tubule architecture and RV function. Colchicine also reduces adverse pulmonary vascular remodeling. These results provide biological plausibility for a clinical trial to repurpose colchicine as a RV-directed therapy for PAH. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Isaac, Barney Thomas Jesudason; Thangakunam, Balamugesh; Cherian, Rekha A; Christopher, Devasahayam Jesudas
2015-01-01
For the follow-up of patients with idiopathic interstitial pneumonias (IIP), it is unclear which parameters of pulmonary function tests (PFT) and exercise testing would correlate best with high-resolution computed tomography (HRCT).. To find out the correlation of symptom scores, PFTs and exercise testing with HRCT scoring in patients diagnosed as idiopathic interstitial pneumonia. Cross-sectional study done in pulmonary medicine outpatients department of a tertiary care hospital in South India. Consecutive patients who were diagnosed as IIP by a standard algorithm were included into the study. Cough and dyspnea were graded for severity and duration. Pulmonary function tests and exercise testing parameters were noted. HRCT was scored based on an alveolar score, an interstitial score and a total score. The HRCT was correlated with each of the clinical and physiologic parameters. Pearson's/Spearman's correlation coefficient was used for the correlation of symptoms and parameters of ABG, PFT and 6MWT with the HRCT scores. A total of 94 patients were included in the study. Cough and dyspnea severity (r = 0.336 and 0.299), FVC (r = -0.48), TLC (r = -0.439) and DLCO and distance saturation product (DSP) (r = -0.368) and lowest saturation (r = -0.324) had significant correlation with total HRCT score. Among these, DLCO, particularly DLCO corrected % of predicted, correlated best with HRCT score (r = -0.721).. Symptoms, PFT and exercise testing had good correlation with HRCT. DLCO corrected % of predicted correlated best with HRCT.
Secondary Pulmonary Hypertension and Right-Sided Heart Failure at Presentation in Grave's Disease
Ganeshpure, Swapnil Panjabrao; Vaidya, Gaurang Nandkishor; Gattani, Vipul
2012-01-01
A young female presented with evidence of right-sided heart failure and was subsequently found to have significant pulmonary artery hypertension (PAH). Because of her normal left ventricular function and pulmonary capillary wedge pressure, the most probable site of etiology seemed to be the pulmonary vasculature. All the common possible secondary causes of PAH were ruled out, but during the investigations, she was found to have elevated thyroid function tests compatible with the diagnosis of Grave's disease. The treatment of Grave's disease, initially by medications and subsequently by radioiodine therapy, was associated with a significant reduction in the pulmonary artery systolic pressure. The purpose of this case report is to highlight one of the unusual and underdiagnosed presentations of Grave's disease. PMID:23198182
Ghanem, Maha K.; Makhlouf, Hoda A.; Agmy, Gamal R.; Imam, Hisham M. K.; Fouad, Doaa A.
2009-01-01
BACKGROUND: A prediction formula for mean pulmonary artery pressure (MPAP) using standard lung function measurement has been recently validated to screen for pulmonary hypertension (PH) in idiopathic pulmonary fibrosis (IPF) patients. OBJECTIVE: To test the usefulness of this formula as a new non invasive screening tool for PH in IPF patients. Also, to study its correlation with patients' clinical data, pulmonary function tests, arterial blood gases (ABGs) and other commonly used screening methods for PH including electrocardiogram (ECG), chest X ray (CXR), trans-thoracic echocardiography (TTE) and computerized tomography pulmonary angiography (CTPA). MATERIALS AND METHODS: Cross-sectional study of 37 IPF patients from tertiary hospital. The accuracy of MPAP estimation was assessed by examining the correlation between the predicted MPAP using the formula and PH diagnosed by other screening tools and patients' clinical signs of PH. RESULTS: There was no statistically significant difference in the prediction of PH using cut off point of 21 or 25 mm Hg (P = 0.24). The formula-predicted MPAP greater than 25 mm Hg strongly correlated in the expected direction with O2 saturation (r = −0.95, P < 0.000), partial arterial O2 tension (r = −0.71, P < 0.000), right ventricular systolic pressure measured by TTE (r = 0.6, P < 0.000) and hilar width on CXR (r = 0.31, P = 0.03). Chest symptoms, ECG and CTPA signs of PH poorly correlated with the same formula (P > 0.05). CONCLUSIONS: The prediction formula for MPAP using standard lung function measurements is a simple non invasive tool that can be used as TTE to screen for PH in IPF patients and select those who need right heart catheterization. PMID:19881164
International spinal cord injury pulmonary function basic data set.
Biering-Sørensen, F; Krassioukov, A; Alexander, M S; Donovan, W; Karlsson, A-K; Mueller, G; Perkash, I; Sheel, A William; Wecht, J; Schilero, G J
2012-06-01
To develop the International Spinal Cord Injury (SCI) Pulmonary Function Basic Data Set within the framework of the International SCI Data Sets in order to facilitate consistent collection and reporting of basic bronchopulmonary findings in the SCI population. International. The SCI Pulmonary Function Data Set was developed by an international working group. The initial data set document was revised on the basis of suggestions from members of the Executive Committee of the International SCI Standards and Data Sets, the International Spinal Cord Society (ISCoS) Executive and Scientific Committees, American Spinal Injury Association (ASIA) Board, other interested organizations and societies and individual reviewers. In addition, the data set was posted for 2 months on ISCoS and ASIA websites for comments. The final International SCI Pulmonary Function Data Set contains questions on the pulmonary conditions diagnosed before spinal cord lesion,if available, to be obtained only once; smoking history; pulmonary complications and conditions after the spinal cord lesion, which may be collected at any time. These data include information on pneumonia, asthma, chronic obstructive pulmonary disease and sleep apnea. Current utilization of ventilator assistance including mechanical ventilation, diaphragmatic pacing, phrenic nerve stimulation and Bi-level positive airway pressure can be reported, as well as results from pulmonary function testing includes: forced vital capacity, forced expiratory volume in one second and peak expiratory flow. The complete instructions for data collection and the data sheet itself are freely available on the website of ISCoS (http://www.iscos.org.uk).
The effect of scoliosis surgery on pulmonary function in spinal muscular atrophy type II patients.
Chou, Shih-Hsiang; Lin, Gau-Tyan; Shen, Po-Chih; Lue, Yi-Jing; Lu, Cheng-Chang; Tien, Yin-Chun; Lu, Yen-Mou
2017-06-01
Various results of the previous literature related to surgical effect on pulmonary function of spinal muscular atrophy (SMA) patients might be due to different SMA type, different fusion level and technique. The aim of this study was to determine the value of scoliosis surgery for SMA type II patients with regard to pulmonary function, under the same fusion level, fusion technique and average long-term follow-up. Ten SMA II patients who underwent spinal correction procedures from 1993 to 2010 were identified. Data on clinical features and pulmonary function, including forced vital capacity (FVC) and forced expiratory volume in 1st second (FEV 1 ), were collected. The data on pulmonary function were divided into preoperative, postoperative short-term (0-5 years), mid-term (5-10 years), and long-term (>10 years). Statistical comparisons were made using the Wilcoxon test for pulmonary function and body weight analysis. Questions were answered by parents on how surgery influenced the frequency of respiratory infection and the ability to sit at school. The average length of postoperative pulmonary function follow-up was 12.3 years (range 4.9-15.9 years). There was no significant difference in FVC or FEV 1 between preoperative and each postoperative period. However, a significant decline from mid-term to long-term was observed (p = 0.028). Body weight increased significantly in all postoperative periods and was moderately correlated to pulmonary function (r = 0.526 for FVC). The answers to the questionnaire revealed that 80% of the patients had obvious improvement in the frequency of respiratory infection and 100% were tolerable sitting at school. Surgical correction for scoliosis in SMA II patients results in pulmonary function being maintained during long-term follow-up. In addition, the advantages of surgery also include body weight gain, better sitting tolerance, and reduced frequency of respiratory infection.
Zhang, Chen; Li, Qiangqiang; Zhu, Yan; Gu, Hong
2014-06-10
To explore the risk and protective factors for pulmonary hypertensive crisis (PHC) in patients with idiopathic pulmonary arterial hypertension (IPAH). A retrospective study was performed for 65 patients with a diagnosis of IPAH between January 2010 and December 2013. According to clinical manifestations, they were divided into two groups of susceptibility and non-susceptibility to PHC. Clinical and hemodynamic parameters were analyzed in univariate and multivariate manners. Among them, there were 32 males and 33 females with a mean age of (14.4 ± 12.3) (10/12-47.3) years. Twenty-three patients had typical manifestations of PHC and 18 of them were induced by exercises.Univariate analysis revealed that the proportion of patients with World Health Organization (WHO) functional class III-IV in PHC-susceptible group was significantly higher than PHC-nonsusceptible group (60.9% vs 23.8%, P = 0.003) while the percentage of patent foramen ovale in PHC-susceptible group was significantly lower than PHC-nonsusceptible group (8.7% vs 45.2%, P = 0.003).In patients with WHO functional classI-II, hemodynamic variables including the decline of pulmonary arterial pressure and positive rate in vasoreactivity testing in PHC-susceptible group were significantly higher than PHC-nonsusceptible group.In patients with WHO functional class III-IV, baseline pulmonary arterial pressure and mean right atrial pressure in PHC-susceptible group were significantly higher than those in PHC-nonsusceptible group. Multivariate Logistic regression analysis revealed that, for those with WHO functional class III-IV (OR = 23.45, 95%CI: 2.85-193.09) and the decline of systolic pulmonary arterial pressure in vasoreactivity testing (OR = 1.12, 95%CI: 1.04-1.22) were independent risk factors for PHC in IPAH patients while patent foramen ovale (OR = 0.01, 95%CI: 0.00-0.52) was a protective factor. PHC in IPAH patients is correlated with WHO functional class, pulmonary vascular reactivity, baseline pulmonary arterial pressure and patent foramen ovale. And exercise is the most common stimulus to PHC.
Arjomandi, Mehrdad; Haight, Thaddeus; Redberg, Rita; Gold, Warren M
2009-06-01
To determine whether the flight attendants who were exposed to secondhand tobacco smoke in the aircraft cabin have abnormal pulmonary function. We administered questionnaires and performed pulmonary function testing in 61 never-smoking female flight attendants who worked in active air crews before the smoking ban on commercial aircraft (preban). Although the preban flight attendants had normal FVC, FEV1, and FEV1/FVC ratio, they had significantly decreased flow at mid- and low-lung volumes, curvilinear flow-volume curves, and evidence of air trapping. Furthermore, the flight attendants had significantly decreased diffusing capacity (77.5% +/- 11.2% predicted normal) with 51% having a diffusing capacity below their 95% normal prediction limit. This cohort of healthy never-smoking flight attendants who were exposed to secondhand tobacco smoke in the aircraft cabin showed pulmonary function abnormalities suggestive of airway obstruction and impaired diffusion.
Nasobronchial allergy and pulmonary function abnormalities among coir workers of Alappuzha.
Panicker, Venugopal; Karunakaran, Raseela; Ravindran, C
2010-07-01
Coir is a commercially important natural fiber obtained from the coconut husk. Coir can be woven into strong twine or rope, and is used for padding mattresses, upholstery, etc. Coir industry provides a major share of occupation to the natives of Alappuzha district of Kerala State. It has been noticed earlier that there is increased incidence of nasobronchial allergy among the population involved in this industry. This study was aimed at recognizing the symptomatology and pulmonary functional impairment among symptomatic coir workers. All coir workers who attended our institute over a period of three years were included in the study. Detailed occupational history was taken; symptom profile was studied in detail, clinical examination and pulmonary function tests conducted. Among the 624 symptomatic coir workers selected for this purpose, 64 patients had purely nasal symptoms, while 560 had symptoms of nasobronchial allergy. 357 patients had reversible obstruction on PFT, while 121 had only small airway obstruction. We conclude that coir work induced nasobronchial allergy and pulmonary function abnormalities. In absence of CT scan and bronchial challenge testing it may be inappropriate to label coir work as occupational hazard. However the present study may be used as thought provoking study to initiate further understanding.
Pulmonary function in adolescents with ataxia telangiectasia.
McGrath-Morrow, Sharon; Lefton-Greif, Maureen; Rosquist, Karen; Crawford, Thomas; Kelly, Amber; Zeitlin, Pamela; Carson, Kathryn A; Lederman, Howard M
2008-01-01
Pulmonary complications are common in adolescents with ataxia telangiectasia (A-T), however objective measurements of lung function may be difficult to obtain because of underlying bulbar weakness, tremors, and difficulty coordinating voluntary respiratory maneuvers. To increase the reliability of pulmonary testing, minor adjustments were made to stabilize the head and to minimize leaks in the system. Fifteen A-T adolescents completed lung volume measurements by helium dilution. To assess for reproducibility of spirometry testing, 10 A-T adolescents performed spirometry on three separate occasions. Total lung capacity (TLC) was normal or just mildly decreased in 12/15 adolescents tested. TLC correlated positively with functional residual capacity (FRC), a measurement independent of patient effort (R2=0.71). The majority of individuals had residual volumes (RV) greater than 120% predicted (10/15) and slow vital capacities (VC) less than 70% predicted (9/15). By spirometry, force vital capacity (FVC) and forced expiratory volume in 1 sec (FEV1) values were reproducible in the 10 individuals who underwent testing on three separate occasions (R=0.97 and 0.96 respectively). Seven of the 10 adolescents had FEV1/FVC ratios>90%. Lung volume measurements from A-T adolescents revealed near normal TLC values with increased RV and decreased VC values. These findings indicate a decreased ability to expire to residual volume rather then a restrictive defect. Spirometry was also found to be reproducible in A-T adolescents suggesting that spirometry testing may be useful for tracking changes in pulmonary function over time in this population. Copyright (c) 2007 Wiley-Liss, Inc.
[Clinical, hemodynamic and angiographic results of total cavo-pulmonary connection].
Jimenez, A C; Neville, P; Chamboux, C; Crenn, R; Vaillant, M C; Marchand, M; Chantepie, A
1998-05-01
The aim of the study was to assess the short and medium term results of total cavo-pulmonary connection based on analysis of the functional status, the cavo-pulmonary circulation and the surgical techniques, and the hepatic consequences. Fifteen patients with congenital defects beyond repair were treated by total cavo-pulmonary connection at Tours between March 1st 1992 and July 30th 1996. There were 12 children (mean age: 6.3 years) and 3 adults aged 25 to 28. Results were assessed by clinical examination, hepatic function tests and cardiovascular investigations including right heart catheterisation with angiography in 14 patients. There were no fatalities. Seven patients were in functional Class I and 8 in Class II at medium term (average follow-up of 33 months). Hepatic function was mildly abnormal in all patients with an increase in serum bilirubin and gamma GT, and a decrease in the coagulation factors. The mean pressures in the atrial channel were 12 mmHg (9-16 mmHg), in the superior vena 13.2 mmHg (10-18 mmHg), in the right pulmonary artery 9.5 mmHg (7-15 mmHg) and 11.6 mmHg (8-16 mmHg) in the left pulmonary artery. Significant residual stenosis of a pulmonary branch was observed in 2 cases. The cavo-pulmonary anastomoses were out of line, one from the other, in all cases. The atrial channel was tubular in 9 cases and dilated with slight stagnation of the contrast medium in its inferior region in 5 cases. Total cavo-pulmonary connection transformed the clinical status of these patients but was associated with minor abnormalities of liver function. The quality of the cavo-pulmonary circulation and the surgical anastomoses was estimated to be satisfactory in the majority of cases.
United in prevention-electrocardiographic screening for chronic obstructive pulmonary disease.
Lazovic, Biljana; Mazic, Sanja; Stajic, Zoran; Djelic, Marina; Zlatkovic-Svenda, Mirjana; Putnikovic, Biljana
2013-01-01
NONE DECLARED. P-wave abnormalities on the resting electrocardiogram have been associated with cardiovascular or pulmonary disease. So far, "Gothic" P wave and verticalization of the frontal plane axis is related to lung disease, particularly obstructive lung disease. We tested if inverted P wave in AVl as a lone criteria of P wave axis >70° could be screening tool for emphysema. 1095 routine electrocardiograms (ECGs) were reviewed which yielded 478 (82,1%) ECGs with vertical P-axis in sinus rhythm. Charts were reviewed for the diagnosis of COPD and emphysema based on medical history and pulmonary function tests. Electrocardiogram is very effective screening tool not only in cardiovascular field but in chronic obstructive pulmonary disease. The verticality of the P axis is usually immediately apparent, making electrocardiogram rapid screening test for emphysema.
Shieh, Tzong-Shiun; Chung, Jui-Jung; Wang, Chung-Jing; Tsai, Perng-Jy; Kuo, Yau-Chang; Guo, How-Ran
2012-02-13
To evaluate pulmonary function and respiratory symptoms in workers engaged in the early manufacturing processes of tea and to identify the associated factors, we conducted a study in a tea production area in Taiwan. We recruited tea workers who engaged in the early manufacturing process in the Mountain Ali area in Taiwan and a comparison group of local office workers who were matched for age, gender, and smoking habits. We performed questionnaire interviews, pulmonary function tests, skin prick tests, and measurement of specific IgE for tea on the participants and assessed tea dust exposures in the tea factories. The 91 participating tea workers had higher prevalence of respiratory symptoms than the comparison group (32 participants). Among tea workers, ball-rolling workers had the highest prevalence of symptoms and the highest exposures of inhalable dusts. At baseline, tea workers had similar pulmonary functions as the comparison group, but compared to the other tea workers ball-rolling workers had a lower ratio of the 1-second forced expiratory volume to forced vital capacity (FEV1/FVC) and a lower maximal mid-expiratory flow rate expressed as% of the predicted value--MMF (%pred). A total of 58 tea workers participated in the on-site investigation and the cross-shift lung function measurements. We found ball-rolling yielded the highest inhalable dust level, panning yielded the highest respirable dust level, and withering yielded the lowest levels of both dusts. Ball-rolling also yielded the highest coarse fraction (defined as inhalable dusts minus respirable dusts), which represented exposures from nose to tracheobronchial tract. During the shift, we observed significant declines in pulmonary function, especially in ball-rolling workers. Multiple regressions showed that age, height, work tasks, coarse fraction, and number of months working in tea manufacturing each year were independent predictors of certain pulmonary function parameters in tea workers. Tea workers engaged in early manufacturing processes of tea have higher prevalence of respiratory symptoms and pulmonary function impairment, which might be related to tea dust exposures, especially the coarse fraction.
Jiménez, Julio; Richter, Jute; Nagatomo, Taro; Salaets, Thomas; Quarck, Rozenn; Wagennar, Allard; Wang, Hongmei; Vanoirbeek, Jeroen; Deprest, Jan; Toelen, Jaan
2016-10-24
Bronchopulmonary dysplasia (BPD) is caused by preterm neonatal lung injury and results in oxygen dependency and pulmonary hypertension. Current clinical management fails to reduce the incidence of BPD, which calls for novel therapies. Fetal rabbits have a lung development that mimics humans and can be used as a translational model to test novel treatment options. In preterm rabbits, exposure to hyperoxia leads to parenchymal changes, yet vascular damage has not been studied in this model. In this study we document the early functional and structural changes of the lung vasculature in preterm rabbits that are induced by hyperoxia after birth. Pulmonary artery Doppler measurements, micro-CT barium angiograms and media thickness of peripheral pulmonary arteries were affected after seven days of hyperoxia when compared to controls. The parenchyma was also affected both at the functional and structural level. Lung function testing showed higher tissue resistance and elastance, with a decreased lung compliance and lung capacity. Histologically hyperoxia leads to fewer and larger alveoli with thicker walls, less developed distal airways and more inflammation than normoxia. In conclusion, we show that the rabbit model develops pulmonary hypertension and developmental lung arrest after preterm lung injury, which parallel the early changes in human BPD. Thus it enables the testing of pharmaceutical agents that target the cardiovascular compartment of the lung for further translation towards the clinic.
Jiménez, Julio; Richter, Jute; Nagatomo, Taro; Salaets, Thomas; Quarck, Rozenn; Wagennar, Allard; Wang, Hongmei; Vanoirbeek, Jeroen; Deprest, Jan; Toelen, Jaan
2016-01-01
Bronchopulmonary dysplasia (BPD) is caused by preterm neonatal lung injury and results in oxygen dependency and pulmonary hypertension. Current clinical management fails to reduce the incidence of BPD, which calls for novel therapies. Fetal rabbits have a lung development that mimics humans and can be used as a translational model to test novel treatment options. In preterm rabbits, exposure to hyperoxia leads to parenchymal changes, yet vascular damage has not been studied in this model. In this study we document the early functional and structural changes of the lung vasculature in preterm rabbits that are induced by hyperoxia after birth. Pulmonary artery Doppler measurements, micro-CT barium angiograms and media thickness of peripheral pulmonary arteries were affected after seven days of hyperoxia when compared to controls. The parenchyma was also affected both at the functional and structural level. Lung function testing showed higher tissue resistance and elastance, with a decreased lung compliance and lung capacity. Histologically hyperoxia leads to fewer and larger alveoli with thicker walls, less developed distal airways and more inflammation than normoxia. In conclusion, we show that the rabbit model develops pulmonary hypertension and developmental lung arrest after preterm lung injury, which parallel the early changes in human BPD. Thus it enables the testing of pharmaceutical agents that target the cardiovascular compartment of the lung for further translation towards the clinic. PMID:27783043
Cardiopulmonary and Metabolic Effects of Yoga in Healthy Volunteers
Divya, T Satheesh; Vijayalakshmi, MT; Mini, K; Asish, K; Pushpalatha, M; Suresh, Varun
2017-01-01
Background: Yoga the spiritual union of mind with the divine intelligence of the universe aims to liberate a human being from conflicts of body–mind duality. Beneficial cardiovascular and pulmonary effects of yoga are in par with aerobic exercise, even amounting to replace the exercise model. We conducted an interventional study in healthy volunteers, to analyze the impact of short-term yoga training on cardiovascular, pulmonary, autonomic function tests, lipid profile, and thyroid function tests. Materials and Methods: A sample of fifty new recruits attending the district yoga center was subject to 75 min yoga practice a day for 41 days. Basal values of cardiovascular, pulmonary, autonomic function tests, lipid profile, and thyroid function tests were recorded before yoga training and were reassessed for postyoga changes after 41 days. Results: After yoga practice there was a significant reduction in the resting heart rate, systolic blood pressure, diastolic blood pressure, and mean blood pressure of the participants. Effects on autonomic function tests were variable and inconclusive. There was a significant increase in forced vital capacity, forced expiratory volume in 1 s, and peak expiratory flow rate after yoga. A significant reduction in body mass index was observed. Effects on metabolic parameters were promising with a significant reduction in fasting blood sugar level, serum total cholesterol, serum triglycerides serum low-density lipoprotein levels, and significant increase in high-density lipoprotein. There was no significant change in thyroid function tests after yoga. Conclusion: Short-term yoga practice has no effect on thyroid functions. Yoga practice was found beneficial in maintaining physiological milieu pertaining to cardiovascular and other metabolic parameters. PMID:29422741
Cardiopulmonary and Metabolic Effects of Yoga in Healthy Volunteers.
Divya, T Satheesh; Vijayalakshmi, M T; Mini, K; Asish, K; Pushpalatha, M; Suresh, Varun
2017-01-01
Yoga the spiritual union of mind with the divine intelligence of the universe aims to liberate a human being from conflicts of body-mind duality. Beneficial cardiovascular and pulmonary effects of yoga are in par with aerobic exercise, even amounting to replace the exercise model. We conducted an interventional study in healthy volunteers, to analyze the impact of short-term yoga training on cardiovascular, pulmonary, autonomic function tests, lipid profile, and thyroid function tests. A sample of fifty new recruits attending the district yoga center was subject to 75 min yoga practice a day for 41 days. Basal values of cardiovascular, pulmonary, autonomic function tests, lipid profile, and thyroid function tests were recorded before yoga training and were reassessed for postyoga changes after 41 days. After yoga practice there was a significant reduction in the resting heart rate, systolic blood pressure, diastolic blood pressure, and mean blood pressure of the participants. Effects on autonomic function tests were variable and inconclusive. There was a significant increase in forced vital capacity, forced expiratory volume in 1 s, and peak expiratory flow rate after yoga. A significant reduction in body mass index was observed. Effects on metabolic parameters were promising with a significant reduction in fasting blood sugar level, serum total cholesterol, serum triglycerides serum low-density lipoprotein levels, and significant increase in high-density lipoprotein. There was no significant change in thyroid function tests after yoga. Short-term yoga practice has no effect on thyroid functions. Yoga practice was found beneficial in maintaining physiological milieu pertaining to cardiovascular and other metabolic parameters.
Haeffener, Mauren Porto; Ferreira, Glória Menz; Barreto, Sérgio Saldanha Menna; Arena, Ross; Dall'Ago, Pedro
2008-11-01
The use of the incentive spirometry (IS) with expiratory positive airway pressure (EPAP) to prevent postoperative pulmonary complications (PPC) after coronary artery bypass graft (CABG) is not well established. This study sought to determine the effects of IS+EPAP after CABG. Thirty-four patients undergoing CABG were randomly assigned to a control group or IS+EPAP group. Maximal respiratory pressures, pulmonary function test, 6-minute walk test and chest x-ray were performed at baseline as well as 1 week and 1 month after CABG. Maximal inspiratory pressure was significantly higher in the IS+EPAP group compared to controls at both 1 week and 1 month (P<.001). Maximal expiratory pressure was significantly higher at 1 month compared to 1 week in IS+EPAP group (P<.01). At 1 month, forced vital capacity and forced expiratory volume in 1 second was significantly higher in IS+EPAP compared to controls (P<.05). Inspiratory capacity was higher at 1 month in IS+EPAP group compared to controls (P<.05). The distance walked in 6-minute walk test was higher at 1 month in IS+EPAP group (P<.001) compared to controls. Lastly, radiological injury score at 1 week was lower in IS+EPAP compared to controls (P<.004). In patients undergoing CABG, IS+EPAP results in improved pulmonary function and 6-minute walk distance as well as a reduction in PPC.
A study on quantifying COPD severity by combining pulmonary function tests and CT image analysis
NASA Astrophysics Data System (ADS)
Nimura, Yukitaka; Kitasaka, Takayuki; Honma, Hirotoshi; Takabatake, Hirotsugu; Mori, Masaki; Natori, Hiroshi; Mori, Kensaku
2011-03-01
This paper describes a novel method that can evaluate chronic obstructive pulmonary disease (COPD) severity by combining measurements of pulmonary function tests and measurements obtained from CT image analysis. There is no cure for COPD. However, with regular medical care and consistent patient compliance with treatments and lifestyle changes, the symptoms of COPD can be minimized and progression of the disease can be slowed. Therefore, many diagnosis methods based on CT image analysis have been proposed for quantifying COPD. Most of diagnosis methods for COPD extract the lesions as low-attenuation areas (LAA) by thresholding and evaluate the COPD severity by calculating the LAA in the lung (LAA%). However, COPD is usually the result of a combination of two conditions, emphysema and chronic obstructive bronchitis. Therefore, the previous methods based on only LAA% do not work well. The proposed method utilizes both of information including the measurements of pulmonary function tests and the results of the chest CT image analysis to evaluate the COPD severity. In this paper, we utilize a multi-class AdaBoost to combine both of information and classify the COPD severity into five stages automatically. The experimental results revealed that the accuracy rate of the proposed method was 88.9% (resubstitution scheme) and 64.4% (leave-one-out scheme).
Cardiopulmonary Exercise Testing in Patients Following Massive and Submassive Pulmonary Embolism.
Albaghdadi, Mazen S; Dudzinski, David M; Giordano, Nicholas; Kabrhel, Christopher; Ghoshhajra, Brian; Jaff, Michael R; Weinberg, Ido; Baggish, Aaron
2018-03-03
Little data exist regarding the functional capacity of patients following acute pulmonary embolism. We sought to characterize the natural history of symptom burden, right ventricular (RV) structure and function, and exercise capacity among survivors of massive and submassive pulmonary embolism. Survivors of submassive or massive pulmonary embolism (n=20, age 57±13.3 years, 8/20 female) underwent clinical evaluation, transthoracic echocardiography, and cardiopulmonary exercise testing at 1 and 6 months following hospital discharge. At 1 month, 9/20 (45%) patients had New York Heart Association II or greater symptoms, 13/20 (65%) demonstrated either persistent RV dilation or systolic dysfunction, and 14/20 (70%) had objective exercise impairment as defined by a peak oxygen consumption (V˙O 2 ) of <80% of age-sex predicted maximal values (16.25 [13.4-20.98] mL/kg per minute). At 6 months, no appreciable improvements in symptom severity, RV structure or function, and peak V˙O 2 (17.45 [14.08-22.48] mL/kg per minute, P =NS) were observed. No patients demonstrated an exercise limitation attributable to either RV/pulmonary vascular coupling, as defined by a VE/VCO 2 slope >33, or a pulmonary mechanical limit to exercise at either time point. Similarly, persistent RV dilation or dysfunction was not significantly related to symptom burden or peak V˙O 2 at either time point. Persistent symptoms, abnormalities of RV structure and function, and objective exercise limitation are common among survivors of massive and submassive pulmonary embolism. Functional impairment appears to be attributable to general deconditioning rather than intrinsic cardiopulmonary limitation, suggesting an important role for prescribed exercise rehabilitation as a means toward improved patient outcomes and quality of life. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Guizilini, Solange; Alves, Daniel F; Bolzan, Douglas W; Cancio, Andreia S A; Regenga, Marisa M; Moreira, Rita S L; Trimer, Renata; Gomes, Walter J
2014-09-01
The aim of this trial was to compare functional capacity, pulmonary shunt fraction and clinical outcomes between patients undergoing pleurotomy with a pleural drain inserted in the sub-xyphoid position and patients with a pleural drain placed in the intercostal position after off-pump coronary artery bypass surgery. Patients were randomized into two groups according to the pleural drain site: Group II (n = 33 intercostal pleural drain); and Group SI (n = 35 sub-xyphoid pleural drain). Functional capacity was assessed by the distance covered on the 6-min walking test performed preoperatively and on postoperative day (POD) 5; in addition, pulmonary function test was determined preoperatively and on POD 1 and 5. Pulmonary shunt fraction was evaluated preoperatively and on POD 1, and clinical outcomes were recorded throughout the study. Group SI had better preservation of lung volumes and capacities in POD compared with Group II (P <0.05). Pulmonary shunt fraction increased in both groups postoperatively; however, Group SI showed a smaller pulmonary shunt fraction (0.26 ± 0.04 vs 0.21 ± 0.04%; P = 0.0014). Functional capacity was significantly reduced in both groups on POD 5; however, Group SI showed better preservation of functional capacity (P = 0.0001). Group SI had better postoperative clinical results, with lower incidence of atelectasis and pleural effusion (P <0.05), lower pain scores (P <0.0001), and shorter orotracheal intubation and hospitalization lengths (P <0.001). Sub-xyphoid pleural drain determined better functional capacity and exercise tolerance with a smaller pulmonary shunt fraction and improved clinical outcomes compared with intercostal pleural drainage after off-pump coronary artery bypass surgery. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Vieira, Ana Karine; Alvim, Cristina Gonçalves; Carneiro, Maria Cristina Marquez; Ibiapina, Cássio da Cunha
2016-01-01
To evaluate pulmonary function and functional capacity in children and adolescents with sickle cell disease. This was a cross-sectional study involving 70 children and adolescents (8-15 years of age) with sickle cell disease who underwent pulmonary function tests (spirometry) and functional capacity testing (six-minute walk test). The results of the pulmonary function tests were compared with variables related to the severity of sickle cell disease and history of asthma and of acute chest syndrome. Of the 64 patients who underwent spirometry, 15 (23.4%) showed abnormal results: restrictive lung disease, in 8 (12.5%); and obstructive lung disease, in 7 (10.9%). Of the 69 patients who underwent the six-minute walk test, 18 (26.1%) showed abnormal results regarding the six-minute walk distance as a percentage of the predicted value for age, and there was a ≥ 3% decrease in SpO2 in 36 patients (52.2%). Abnormal pulmonary function was not significantly associated with any of the other variables studied, except for hypoxemia and restrictive lung disease. In this sample of children and adolescents with sickle cell disease, there was a significant prevalence of abnormal pulmonary function. The high prevalence of respiratory disorders suggests the need for a closer look at the lung function of this population, in childhood and thereafter. Avaliar a função pulmonar e a capacidade funcional em crianças e adolescentes com doença falciforme. Estudo transversal com 70 crianças e adolescentes com doença falciforme (8-15 anos), submetidos a testes de função respiratória (espirometria) e de capacidade funcional (teste de caminhada de seis minutos). Os resultados da avaliação da função pulmonar foram comparados com variáveis relacionadas à gravidade da doença falciforme e à presença de história de asma e de síndrome torácica aguda. Dos 64 pacientes submetidos à espirometria, 15 (23,4%) apresentaram resultados alterados: distúrbio ventilatório restritivo, em 8; (12,5%) e distúrbio respiratório obstrutivo, em 7 (10,9%). Dos 69 pacientes submetidos ao teste de caminhada de seis minutos, 18 (26,1%) apresentaram resultados alterados na distância em % do previsto para a idade, e houve uma queda ≥ 3% na SpO2 em 36 (52,2%) dos pacientes. Não houve associações significativas entre função pulmonar alterada e as outras variáveis analisadas, exceto para hipoxemia e distúrbio ventilatório restritivo. Observou-se uma significativa prevalência de alterações na função pulmonar nesta amostra de crianças e adolescentes com doença falciforme. A elevada prevalência de distúrbios ventilatórios sugere a necessidade de um olhar mais atento à função pulmonar desde a infância nessa população.
Pulmonary Function, Muscle Strength and Mortality in Old Age
Buchman, A. S.; Boyle, P. A.; Wilson, R.S.; Gu, Liping; Bienias, Julia L.; Bennett, D. A.
2009-01-01
Numerous reports have linked extremity muscle strength with mortality but the mechanism underlying this association is not known. We used data from 960 older persons without dementia participating in the Rush Memory and Aging Project to test two sequential hypotheses: first, that extremity muscle strength is a surrogate for respiratory muscle strength, and second, that the association of respiratory muscle strength with mortality is mediated by pulmonary function. In a series of proportional hazards models, we first demonstrated that the association of extremity muscle strength with mortality was no longer significant after including a term for respiratory muscle strength, controlling for age, sex, education, and body mass index. Next, the association of respiratory muscle strength with mortality was attenuated by more than 50% and no longer significant after including a term for pulmonary function. The findings were unchanged after controlling for cognitive function, parkinsonian signs, physical frailty, balance, physical activity, possible COPD, use of pulmonary medications, vascular risk factors including smoking, chronic vascular diseases, musculoskeletal joint pain, and history of falls. Overall, these findings suggest that pulmonary function may partially account for the association of muscle strength and mortality. PMID:18755207
20 CFR 718.202 - Determining the existence of pneumoconiosis.
Code of Federal Regulations, 2010 CFR
2010-04-01
... radiologic technologist or technician and there is no evidence that the claim has been fraudulently... term other evidence means medical tests such as blood-gas studies, pulmonary function studies or physical examinations or medical histories which establish the presence of a chronic pulmonary, respiratory...
Güvenç, Tolga Sinan; Erer, Hatice Betül; Kul, Seref; Perinçek, Gökhan; Ilhan, Sami; Sayar, Nurten; Yıldırım, Binnaz Zeynep; Doğan, Coşkun; Karabağ, Yavuz; Balcı, Bahattin; Eren, Mehmet
2013-01-01
Pulmonary vasculature is affected in patients with chronic pulmonary obstructive disease (COPD). As a result of increased pulmonary resistance, right ventricular morphology and function are altered in COPD patients. High altitude and related hypoxia causes pulmonary vasoconstriction, thereby affecting the right ventricle. We aimed to investigate the combined effects of COPD and altitude-related chronic hypoxia on right ventricular morphology and function. Forty COPD patients living at high altitude (1768 m) and 41 COPD patients living at sea level were enrolled in the study. All participants were diagnosed as COPD by a pulmonary diseases specialist depending on symptoms, radiologic findings and pulmonary function test results. Detailed two-dimensional echocardiography was performed by a cardiologist at both study locations. Oxygen saturation and mean pulmonary artery pressure were higher in the high altitude group. Right ventricular end diastolic diameter, end systolic diameter, height and end systolic area were significantly higher in the high altitude group compared to the sea level group. Parameters of systolic function, including tricuspid annular systolic excursion, systolic velocity of tricuspid annulus and right ventricular isovolumic acceleration were similar between groups, while fractional area change was significantly higher in the sea level groups compared to the high altitude group. Indices of diastolic function and myocardial performance index were similar between groups. An increase in mean pulmonary artery pressure and right ventricular dimensions are observed in COPD patients living at high altitude. Despite this increase, systolic and diastolic functions of the right ventricle, as well as global right ventricular performance are similar in COPD patients living at high altitude and sea level. Altitude-related adaptation to chronic hypoxia could explain these findings. Copyright © 2012 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Acute pulmonary effects of nitrogen dioxide exposure during exercise in competitive athletes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, S.U.; Koenig, J.Q.; Pierson, W.E.
The acute pulmonary responses of athletes after short-term exposure to ambient concentrations of NO{sub 2} during heavy exercise have been examined. Intercollegiate male athletes were screened for history of cardiac disease, respiratory disease, allergic conditions and extensive exposure to pollutants. After completion of serum IgE level determination, exercise tolerance test and methacholine challenge test with normal results, nine healthy subjects 18 to 23 years of age were exposed to filtered air and to 0.18 and 0.30 ppm NO{sub 2} for 30 min on different days while exercising on a treadmill. Pulmonary function parameters were measured before and after each exposure.more » In this study, no statistically significant changes were observed in FEV1, RT PEFR, and Vmax50% after exposure to 0.18 and 0.30 ppm NO{sub 2}. For these selected healthy athletes, short-term exposure to ambient NO{sub 2} levels during heavy exercise does not affect adversely the pulmonary function.« less
Calik-Kutukcu, Ebru; Savci, Sema; Saglam, Melda; Vardar-Yagli, Naciye; Inal-Ince, Deniz; Arikan, Hulya; Aribas, Zeynep; Ozer, Ozge; Bosnak-Guclu, Meral; Coplu, Lutfi
2014-01-27
Chronic obstructive pulmonary disease (COPD) has significant systemic effects that substantially impact quality of life and survival. The purpose of this study was to assess and compare peripheral muscle strength and endurance, exercise capacity, fatigue perception and quality of life between patients with COPD and healthy subjects. Twenty COPD patients (mean FEV1 49.3 ± 19.2%) and 20 healthy subjects were included in the study. Pulmonary function testing and six-minute walk test (6MWT) were performed. Peripheral muscle strength was measured with a hand-held dynamometer, peripheral muscle endurance was evaluated with sit-ups, squats and modified push-ups tests. Fatigue perception was assessed using the Fatigue Impact Scale (FIS) and Fatigue Severity Scale (FSS). General quality of life was determined with the Nottingham Health Profile (NHP), and cough-specific quality of life was evaluated with the Leicester Cough Questionnaire (LCQ). Pulmonary functions, strength of shoulder abductor and flexor muscles, numbers of sit-ups and squats, 6MWT distance and 6MWT% were significantly lower in COPD patients than in healthy subjects (p < 0.05). FIS psychosocial sub-dimension and total scores, NHP scores for all sub-dimensions except pain sub-dimension of the COPD group were significantly higher than those of healthy subjects (p < 0.05). The LCQ physical, psychological and social sub-dimensions and total scores were significantly lower in COPD patients than in healthy subjects (p < 0.05). Pulmonary functions, peripheral muscle strength and endurance, exercise capacity and quality of life were adversely affected in patients with COPD. There are greater effect of fatigue on psychosocial functioning and general daily life activities and effect of cough on the quality of life in patients with COPD. This study supports the idea that COPD patients must be evaluated in a comprehensive manner for planning pulmonary rehabilitation programs.
2014-01-01
Background Chronic obstructive pulmonary disease (COPD) has significant systemic effects that substantially impact quality of life and survival. The purpose of this study was to assess and compare peripheral muscle strength and endurance, exercise capacity, fatigue perception and quality of life between patients with COPD and healthy subjects. Methods Twenty COPD patients (mean FEV1 49.3 ± 19.2%) and 20 healthy subjects were included in the study. Pulmonary function testing and six-minute walk test (6MWT) were performed. Peripheral muscle strength was measured with a hand-held dynamometer, peripheral muscle endurance was evaluated with sit-ups, squats and modified push-ups tests. Fatigue perception was assessed using the Fatigue Impact Scale (FIS) and Fatigue Severity Scale (FSS). General quality of life was determined with the Nottingham Health Profile (NHP), and cough-specific quality of life was evaluated with the Leicester Cough Questionnaire (LCQ). Results Pulmonary functions, strength of shoulder abductor and flexor muscles, numbers of sit-ups and squats, 6MWT distance and 6MWT% were significantly lower in COPD patients than in healthy subjects (p < 0.05). FIS psychosocial sub-dimension and total scores, NHP scores for all sub-dimensions except pain sub-dimension of the COPD group were significantly higher than those of healthy subjects (p < 0.05). The LCQ physical, psychological and social sub-dimensions and total scores were significantly lower in COPD patients than in healthy subjects (p < 0.05). Conclusions Pulmonary functions, peripheral muscle strength and endurance, exercise capacity and quality of life were adversely affected in patients with COPD. There are greater effect of fatigue on psychosocial functioning and general daily life activities and effect of cough on the quality of life in patients with COPD. This study supports the idea that COPD patients must be evaluated in a comprehensive manner for planning pulmonary rehabilitation programs. PMID:24468029
[MRI methods for pulmonary ventilation and perfusion imaging].
Sommer, G; Bauman, G
2016-02-01
Separate assessment of respiratory mechanics, gas exchange and pulmonary circulation is essential for the diagnosis and therapy of pulmonary diseases. Due to the global character of the information obtained clinical lung function tests are often not sufficiently specific in the differential diagnosis or have a limited sensitivity in the detection of early pathological changes. The standard procedures of pulmonary imaging are computed tomography (CT) for depiction of the morphology as well as perfusion/ventilation scintigraphy and single photon emission computed tomography (SPECT) for functional assessment. Magnetic resonance imaging (MRI) with hyperpolarized gases, O2-enhanced MRI, MRI with fluorinated gases and Fourier decomposition MRI (FD-MRI) are available for assessment of pulmonary ventilation. For assessment of pulmonary perfusion dynamic contrast-enhanced MRI (DCE-MRI), arterial spin labeling (ASL) and FD-MRI can be used. Imaging provides a more precise insight into the pathophysiology of pulmonary function on a regional level. The advantages of MRI are a lack of ionizing radiation, which allows a protective acquisition of dynamic data as well as the high number of available contrasts and therefore accessible lung function parameters. Sufficient clinical data exist only for certain applications of DCE-MRI. For the other techniques, only feasibility studies and case series of different sizes are available. The clinical applicability of hyperpolarized gases is limited for technical reasons. The clinical application of the techniques described, except for DCE-MRI, should be restricted to scientific studies.
Piccinino, Cristina; Giubertoni, Ailia; Zanaboni, Jacopo; Gravellone, Miriam; Sola, Daniele; Rosso, Roberta; Ferrarotti, Lorena; Marino, Paolo Nicola
2017-11-01
Increased right atrial size is related to adverse prognosis in pulmonary hypertension. The potential incremental value of right atrial function assessment is still unclear. We tested the relationship between right atrial two-dimensional speckle-tracking echocardiography impairment and hemodynamic, functional and clinical deterioration in patients with pulmonary hypertension. We prospectively evaluated 36 patients (27 female, 9 male; mean age 68 ± 13 years) with suspected pulmonary hypertension undergoing right heart catheterization and 16 matched controls. All patients underwent baseline evaluation by New York Heart Association functional class, 6-min walking test, brain natriuretic peptide (BNP), and standard two-dimensional echocardiography in less than 48 h of right heart catheterization. Right atrial two-dimensional speckle-tracking echocardiography was assessed by averaging all segments in standard four-chamber apical view. Right atrial global integral strain was significantly lower in patients compared with controls (11.40 ± 5.22% vs. 25.72 ± 5.95 P < 0.001). Moreover, right atrial global strain, but not right atrial area or volume, was correlated with invasively measured cardiac index (CI) (r = 0.72; P < 0.0001) and pulmonary vascular resistances in all patients, even though stronger in subjects with precapillary pulmonary hypertension (r = -0.42, P = 0.018; r = -0.54, P = 0.007 respectively; P = 0.007). It was also correlated with New York Heart Association (P = 0.027), BNP (P = 0.002), and 6-min walking test (P = 0.006). After multivariate analysis including right atrial volume, tricuspid annular plane systolic excursion, left atrial strain, and BNP, right atrial global strain showed the strongest correlation with CI. Area under the curve optimal cutoff for predicting CI at least 2.4 l/min/m was 17% (area under the curve: 0.83, sensitivity: 90%, specificity: 54%). Right atrial global strain can identify right atrial functional impairment before structural changes and may be implemented in a comprehensive, noninvasive right heart assessment for diagnosis and follow-up of pulmonary hypertension patients.
Marques, Tanyse Bahia Carvalho; Neves, Juliana de Carvalho; Portes, Leslie Andrews; Salge, João Marcos; Zanoteli, Edmar; Reed, Umbertina Conti
2014-01-01
OBJECTIVE: Respiratory complications are the main causes of morbidity and mortality in patients with neuromuscular disease (NMD). The objectives of this study were to determine the effects that routine daily home air-stacking maneuvers have on pulmonary function in patients with spinal muscular atrophy (SMA) and in patients with congenital muscular dystrophy (CMD), as well as to identify associations between spinal deformities and the effects of the maneuvers. METHODS: Eighteen NMD patients (ten with CMD and eight with SMA) were submitted to routine daily air-stacking maneuvers at home with manual resuscitators for four to six months, undergoing pulmonary function tests before and after that period. The pulmonary function tests included measurements of FVC; PEF; maximum insufflation capacity (MIC); and assisted and unassisted peak cough flow (APCF and UPCF, respectively) with insufflations. RESULTS: After the use of home air-stacking maneuvers, there were improvements in the APCF and UPCF. In the patients without scoliosis, there was also a significant increase in FVC. When comparing patients with and without scoliosis, the increases in APCF and UPCF were more pronounced in those without scoliosis. CONCLUSIONS: Routine daily air-stacking maneuvers with a manual resuscitator appear to increase UPCF and APCF in patients with NMD, especially in those without scoliosis. PMID:25410841
Castellví, Ivan; Simeón-Aznar, Carmen Pilar; Sarmiento, Mónica; Fortuna, Ana; Mayos, Mercedes; Geli, Carme; Diaz-Torné, César; Moya, Patricia; De Llobet, Josep Maria; Casademont, Jordi
2015-02-01
To determine whether there is an association between different capillaroscopic findings and pulmonary function tests in systemic sclerosis (SSc). We did a retrospective observational study in a cohort of patients with SSc and early SSc. Patients with at least 1 nailfold videocapillaroscopy (NVC) magnified 120× were included. Pathological findings were giant capillaries, angiogenesis, and density loss. Findings were compared with lung function values: percent expected value of forced vital capacity (FVC), DLCO, and FVC/DLCO ratio. Other variables collected were sex and SSc type, and the presence of digital ulcers (DU), interstitial lung disease (ILD), scleroderma renal crisis, and/or pulmonary hypertension (PH). Of 136 patients with SSc, 85 had undergone an NVC. The frequency of ILD, DU, and PH was 24.1%, 28.7%, and 17.2%, respectively. Data analysis showed that patients with density loss had worse FVC% (86.91 ± 19.42 vs 101.13 ± 16.06, p < 0.01) and DLCO% (71.43 ± 21.19 vs 85.9 ± 19.81, p < 0.01) compared to those without. Patients with loss of density present worse FVC and DLCO values. Prospective studies are warranted to determine whether NVC is useful for studying pulmonary function in SSc.
Marques, Tanyse Bahia Carvalho; Neves, Juliana de Carvalho; Portes, Leslie Andrews; Salge, João Marcos; Zanoteli, Edmar; Reed, Umbertina Conti
2014-10-01
Respiratory complications are the main causes of morbidity and mortality in patients with neuromuscular disease (NMD). The objectives of this study were to determine the effects that routine daily home air-stacking maneuvers have on pulmonary function in patients with spinal muscular atrophy (SMA) and in patients with congenital muscular dystrophy (CMD), as well as to identify associations between spinal deformities and the effects of the maneuvers. Eighteen NMD patients (ten with CMD and eight with SMA) were submitted to routine daily air-stacking maneuvers at home with manual resuscitators for four to six months, undergoing pulmonary function tests before and after that period. The pulmonary function tests included measurements of FVC; PEF; maximum insufflation capacity (MIC); and assisted and unassisted peak cough flow (APCF and UPCF, respectively) with insufflations. After the use of home air-stacking maneuvers, there were improvements in the APCF and UPCF. In the patients without scoliosis, there was also a significant increase in FVC. When comparing patients with and without scoliosis, the increases in APCF and UPCF were more pronounced in those without scoliosis. Routine daily air-stacking maneuvers with a manual resuscitator appear to increase UPCF and APCF in patients with NMD, especially in those without scoliosis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wallaert, B.; Ramon, P.; Fournier, E.
1982-11-01
Results of bronchoalveolar lavage (BAL), 67Ga scanning, and serum angiotensin-converting enzyme (SACE) assay are compared in the assessment of pulmonary involvement in ten cases of extrathoracic sarcoidosis. Standard clinical, radiologic, and pulmonary function tests detected no pulmonary changes in these patients, but BAL demonstrated an increased alveolar lymphocytosis in eight of ten cases. SACE levels were increased in two cases, and the thoracic gallium uptake was normal in all cases. BAL appears to be the best technique for diagnosing latent pulmonary involvement in extrathoracic sarcoidosis.
Validation of the plain chest radiograph for epidemiologic studies of airflow obstruction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Musk, A.W.
The chest radiographs of 125 industrial workers from rural New South Wales were examined for overinflated lungs, with and without attenuated midzonal vessels. Although the mean values of a comprehensive range of pulmonary function tests in the whole group were within normal limits, the nine subjects whose radiographs showed overinflated lungs and attenuated vessels had significantly impaired pulmonary function in comparison with 85 subjects with normal radiographs. The mean values for these nine subjects, expressed as a percentage of the mean value for subjects with normal radiographs, were: forced expiratory volume in 1 second, 75%; total lung capacity, 107%; residualmore » volume, 143%; transpulmonary pressure at maximum inspiration, 60%; static deflation compliance, 158%; lung volume at transpulmonary pressure 10 cm H/sub 2/O, 132%; transfer factor, 79%; and transfer factor/alveolar volume, 77%. Similar results were obtained by a second observer. Those subjects with overinflation but no vascular attenuation had significantly larger mean values for vital capacity and alveolar volume but no significant difference in total lung capacity or other tests of the mechanical properties of the lungs. Agreement on the presence of a positive sign between the two observers expressed as a percentage of those considered positive by either was 81% for overinflation and 62% for attenuated midzonal vessels. The results indicate that in groups of subjects with normal-average values of pulmonary function, the plain chest radiograph may provide information concerning pulmonary structure that is reflected in tests of function.« less
Ueno, Fumika; Kitaguchi, Yoshiaki; Shiina, Takayuki; Asaka, Shiho; Miura, Kentaro; Yasuo, Masanori; Wada, Yosuke; Yoshizawa, Akihiko; Hanaoka, Masayuki
2017-01-01
It remains unclear whether the preoperative pulmonary function parameters and prognostic indices that are indicative of nutritional and immunological status are associated with prognosis in lung cancer patients with combined pulmonary fibrosis and emphysema (CPFE) who have undergone surgery. The aim of this study is to identify prognostic determinants in these patients. The medical records of all patients with lung cancer associated with CPFE who had undergone surgery at Shinshu University Hospital were retrospectively reviewed to obtain clinical data, including the results of preoperative pulmonary function tests and laboratory examinations, chest high-resolution computed tomography (HRCT), and survival. Univariate Cox proportional hazards regression analysis showed that a high pathological stage of the lung cancer, a higher preoperative serum carcinoembryonic antigen level, and a higher preoperative composite physiologic index (CPI) were associated with a high risk of death. Multivariate analysis showed that a high pathological stage of the lung cancer (HR: 1.579; p = 0.0305) and a higher preoperative CPI (HR: 1.034; p = 0.0174) were independently associated with a high risk of death. In contrast, the severity of fibrosis or emphysema on chest HRCT, the individual pulmonary function parameters, the prognostic nutritional index, the neutrophil-to-lymphocyte ratio, and the platelet-to-lymphocyte ratio were not associated with prognosis. In the Kaplan-Meier analysis, the log-rank test showed significant differences in survival between the high-CPI and the low-CPI group (p = 0.0234). The preoperative CPI may predict mortality and provide more powerful prognostic information than individual pulmonary function parameters in lung cancer patients with CPFE who have undergone surgery. © 2017 S. Karger AG, Basel.
Kieran, S M; Cahill, R A; Browne, I; Sheehan, S J; Mehigan, D; Barry, M C
2006-09-01
Concern about the potential detrimental side-effects of beta-blockade on pulmonary function often dissuades against their perioperative use in patients undergoing major arterial surgery (especially in those with chronic obstructive pulmonary disease (COPD)). In this study we aimed to establish prospectively the clinical relevance of these concerns. After ethics committee approval and individual informed consent, the pulmonary function of twenty patients (mean age 68.7 years (range 43-82), 11 males) scheduled to undergo non-emergency major vascular surgery was studied by recording symptoms and spirometry before and after institution of effective beta-blockade. Fifteen patients (75%) had significant smoking histories (mean pack years/patient=50), while 12 (60%) had COPD. All patients tolerated effective beta-blockade satisfactorily without developing either subjective deterioration in symptoms or significant change on spirometry. The mean change in FEV1 following adequate beta-blockade was 0.05+/-0.24 liters (95% CI -0.06 to +1.61), p=0.35, giving a mean percentage change of 3.18%+/-11.66 (95% CI -2.26 to 8.62). Previously held concerns about worsening pulmonary function through the short-term use of beta-blockers should not dissuade their perioperative usage in patients with peripheral vascular disease. Furthermore, the accuracy of pulmonary function tests in preoperative assessment and risk stratification also appears unaffected by this therapy.
Pulmonary arterial stiffening in COPD and its implications for right ventricular remodelling.
Weir-McCall, Jonathan R; Liu-Shiu-Cheong, Patrick Sk; Struthers, Allan D; Lipworth, Brian J; Houston, J Graeme
2018-02-27
Pulmonary pulse wave velocity (PWV) allows the non-invasive measurement of pulmonary arterial stiffening, but has not previously been assessed in COPD. The aim of the current study was to assess PWV in COPD and its association with right ventricular (RV) remodelling. Fifty-eight participants with COPD underwent pulmonary function tests, 6-min walk test and cardiac MRI, while 21 healthy controls (HCs) underwent cardiac MRI. Thirty-two COPD patients underwent a follow-up MRI to assess for longitudinal changes in RV metrics. Cardiac MRI was used to quantify RV mass, volumes and PWV. Differences in continuous variables between the COPD and HC groups was tested using an independent t-test, and associations between PWV and right ventricular parameters was examined using Pearson's correlation coefficient. Those with COPD had reduced pulsatility (COPD (mean±SD):24.88±8.84% vs. HC:30.55±11.28%, p=0.021), pulmonary acceleration time (COPD:104.0±22.9ms vs. HC: 128.1±32.2ms, p<0.001), higher PWV (COPD:2.62±1.29ms -1 vs. HC:1.78±0.72ms -1 , p=0.001), lower RV end diastolic volume (COPD:53.6±11.1ml vs. HC:59.9±13.0ml, p=0.037) and RV stroke volume (COPD:31.9±6.9ml/m 2 vs. HC:37.1±6.2ml/m 2 , p=0.003) with no difference in mass (p=0.53). PWV was not associated with right ventricular parameters. While pulmonary vascular remodelling is present in COPD, cardiac remodelling favours reduced filling rather than increased afterload. Treatment of obstructive lung disease may have greater effect on cardiac function than treatment of pulmonary vascular disease in most COPD patients KEY POINTS: • Pulmonary pulse wave velocity (PWV) is elevated in COPD. • Pulmonary PWV is not associated with right ventricular remodelling. • Right ventricular remodelling is more in keeping with that of reduced filling.
Lung imaging in pulmonary disease
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taplin, G.V.; Chopra, S.K.
1976-01-01
Although it has been recognized for several years that chronic obstructive pulmonary disease (COPD) can cause lung perfusion defects which may simulate pulmonary embolism, relatively little use has been made of either the radioxenon or the radioaerosol inhalation lung imaging procedures until the last few years as a means of distinguishing pulmonary embolism (P.E.) from COPD is reported. Recent experience is reported with the use of both of these procedures in comparison with pulmonary function tests for the early detection of COPD in population studies and also in P.E. suspects. Equal emphasis is given to simultaneous aerosol ventilation-perfusion (V/P) imagingmore » in the differential diagnosis of P.E. Finally, this paper is concerned with new developments in regional lung diffusion imaging following the inhalation of radioactive gases and rapidly absorbed radioaerosols. Their experimental basis is presented and their potential clinical applications in pulmonary embolism are discussed. As a result of these investigations, a functional (V/P) diagnosis of pulmonary embolism in patients may be possible in the near future with a sequential radioaerosol inhalation procedure alone.« less
Lee, Ji Hyun; Hong, A Ram; Kim, Jung Hee; Kim, Kyoung Min; Koo, Bo Kyung; Shin, Chan Soo; Kim, Sang Wan
2018-01-01
Smoking induces bone loss; however, data on the relationship between smoking history and bone mineral density (BMD) are lacking. Age and pulmonary function can affect BMD. We investigated the relationships among pack-years (PYs) of smoking, pulmonary function, and BMD in middle-aged Korean men (50-64 years old). This cross-sectional study used data from the Korean National Health and Nutrition Examination Survey, 2008-2011. All participants underwent BMD measurements using dual energy X-ray absorptiometry and pulmonary function tests using standardized spirometry. In total, 388 never-smokers and 1088 ever-smokers were analyzed. The number of PYs of smoking was negatively correlated with total hip BMD (r = -0.088; P = 0.004) after adjusting for age, height, and weight. Ever-smokers were classified into 3 groups according to PYs of smoking. The highest tertile (n = 482) exhibited significantly lower total hip bone mass than the lowest tertile (n = 214) after adjusting for confounding factors (age, height, weight, forced expiratory volume in 1 s (FEV 1 ), alcohol consumption, physical activity, and vitamin D levels) that could affect bone metabolism (P = 0.003). In conclusion, smoking for >30 PYs was significantly associated with low hip BMD after adjusting for pulmonary function in middle-aged Korean men. Long-term smoking may be a risk factor for bone loss in middle-aged men independent of age, height, weight, and pulmonary function.
Henno, Priscilla; Grassin-Delyle, Stanislas; Belle, Emeline; Brollo, Marion; Naline, Emmanuel; Sage, Edouard; Devillier, Philippe; Israël-Biet, Dominique
2017-05-23
Tobacco-induced pulmonary vascular disease is partly driven by endothelial dysfunction. The Sonic hedgehog (SHH) pathway is involved in vascular physiology. We sought to establish whether the SHH pathway has a role in pulmonary endothelial dysfunction in smokers. The ex vivo endothelium-dependent relaxation of pulmonary artery rings in response to acetylcholine (Ach) was compared in 34 current or ex-smokers and 8 never-smokers. The results were expressed as a percentage of the contraction with phenylephrine. We tested the effects of SHH inhibitors (GANT61 and cyclopamine), an SHH activator (SAG) and recombinant VEGF on the Ach-induced relaxation. The level of VEGF protein in the pulmonary artery ring was measured in an ELISA. SHH pathway gene expression was quantified in reverse transcriptase-quantitative polymerase chain reactions. Ach-induced relaxation was much less intense in smokers than in never-smokers (respectively 24 ± 6% and 50 ± 7% with 10 -4 M Ach; p = 0.028). All SHH pathway genes were expressed in pulmonary artery rings from smokers. SHH inhibition by GANT61 reduced Ach-induced relaxation and VEGF gene expression in the pulmonary artery ring. Recombinant VEGF restored the ring's endothelial function. VEGF gene and protein expression levels in the pulmonary artery rings were positively correlated with the degree of Ach-induced relaxation and negatively correlated with the number of pack-years. SHH pathway genes and proteins are expressed in pulmonary artery rings from smokers, where they modulate endothelial function through VEGF.
United in Prevention–Electrocardiographic Screening for Chronic Obstructive Pulmonary Disease
Mazic, Sanja; Stajic, Zoran; Djelic, Marina; Zlatkovic-Svenda, Mirjana; Putnikovic, Biljana
2013-01-01
CONFLICT OF INTEREST: NONE DECLARED Introduction P-wave abnormalities on the resting electrocardiogram have been associated with cardiovascular or pulmonary disease. So far, “Gothic” P wave and verticalization of the frontal plane axis is related to lung disease, particularly obstructive lung disease. Aim We tested if inverted P wave in AVl as a lone criteria of P wave axis >70° could be screening tool for emphysema. Material and method 1095 routine electrocardiograms (ECGs) were reviewed which yielded 478 (82,1%) ECGs with vertical P-axis in sinus rhythm. Charts were reviewed for the diagnosis of COPD and emphysema based on medical history and pulmonary function tests. Conclusion Electrocardiogram is very effective screening tool not only in cardiovascular field but in chronic obstructive pulmonary disease. The verticality of the P axis is usually immediately apparent, making electrocardiogram rapid screening test for emphysema. PMID:24058253
High resolution multidetector CT aided tissue analysis and quantification of lung fibrosis
NASA Astrophysics Data System (ADS)
Zavaletta, Vanessa A.; Karwoski, Ronald A.; Bartholmai, Brian; Robb, Richard A.
2006-03-01
Idiopathic pulmonary fibrosis (IPF, also known as Idiopathic Usual Interstitial Pneumontis, pathologically) is a progressive diffuse lung disease which has a median survival rate of less than four years with a prevalence of 15-20/100,000 in the United States. Global function changes are measured by pulmonary function tests and the diagnosis and extent of pulmonary structural changes are typically assessed by acquiring two-dimensional high resolution CT (HRCT) images. The acquisition and analysis of volumetric high resolution Multi-Detector CT (MDCT) images with nearly isotropic pixels offers the potential to measure both lung function and structure. This paper presents a new approach to three dimensional lung image analysis and classification of normal and abnormal structures in lungs with IPF.
Liao, Hua; Shen, Ying; Wang, Pengjun
2015-05-01
To study the pulmonary function and nasal resistance characteristics of patients with chronic nose-sinusitis and nasal polyps (CRSwNP), to explore the evaluation role of nasal resistance in nasal ventilation function and the effect of endoscopic sinus surgery on pulmonary function in patients with CRSwNP. Fifty CRSwNP patients that met the study criteria were selected . The patients were performed endoscopic surgeries according to Messerklinger surgical procedures under general anesthesia. Extent of surgery was based on preoperative CT showing the range of the lesion of disease and endoscopic findings. Perioperative treatments contained intranasal corticosteroids, cephalosporin or penicillin antibiotics, nasal irrigation and other treatments. Main outcome measures included visual analog scale (VAS), endoscopic Lind-Kennedy scores, nasal resistence, pulmonary function in patientsone week before and after surgery, three months and six months after surgery. Pulmonary function includes forced expiratory volume in one second (FEV1), forced vital capacity FEV1/FVC and peak expiratory flow (PEF). The study found that there were significantly positive correlations among VAS score, Lund-Kennedy score and nasal resistance (P < 0.05) in CRSwNP patients, but there is a significantly negative correlation between VAS score, Lund-Kennedy score, nasal resistance and pulmonary function indexes of FEV1, FVC and PEF (P < 0.05). The VAS score, Lund-Kennedy score and nasal resistance values of CRSwNP patients were decreased significantly after comprehensive treatments with nasal endoscopic operation as the major one, the difference was statistically different (P < 0.05). And the pulmonary function indexs (FEV1, FVC, PEF) were significantly increased after surgery in CRSwNP patients. The nasal resistance can objectively and reliably reflect the degree of nasal congestion and the recovery of nasal function in CRSwNP patients after endoscopic sinus surgery. The detection method of nasal resistance is simple. Functional endoscopic sinus surgery can effectively improve the pulmonary ventilation function in CRSwNP patients, providing some clinical references about the prevention and treatment of CRS related lower respiratory disease.
The prevalence of reversible airway obstruction in professional football players.
Ross, R G
2000-12-01
To determine the prevalence of reversible airway obstruction in a group of professional football training camp participants. All attendees at a Canadian Football League team rookie preseason training camp were invited to participate in a protocol designed to elicit symptoms and signs of reversible airway obstruction (asthma) during the initial preparticipation examination. Those agreeing to the protocol completed a questionnaire containing standardized inquiries about a past history of asthma and the presence of symptoms. Participants then underwent spirometry testing to determine lung function before and after receiving a standardized dose of bronchodilator medication. Players showing evidence of airway obstruction during initial testing and still on the team roster underwent repeat spirometry testing and formal pulmonary function testing during the football season. The follow-up pulmonary function tests were performed to determine those that might benefit from treatment for asthma. Nineteen of 34 (56%) players agreeing to participate had significant reversible airway obstruction as defined by a 12% or greater reversibility in forced expiratory volume in one second (FEV1), peak expiratory flow rate (PEFR), and/or forced expiratory flow rate between 25 and 75% of forced vital capacity (FEF 25-75). In most participants, the diagnosis was made on the basis of spirometry alone. Of those testing positive during initial inquiry, 88% remained positive on repeat spirometry, and 73% had reversible airway obstruction during more stringently controlled hospital-based pulmonary function testing. Those players treated for previously undiagnosed asthma noted an improvement in subjective athletic performance during the football season. Based on the remarkably high prevalence of undiagnosed asthma in this group, it may prove worthwhile to test elite football players using lung function parameters.
Gómez Garrido, Alba; León Espitia, Ana María; Montesinos Magraner, Lluïsa; Ramirez Galceran, Lucrecia; Soler Canudes, Emilia; González Viejo, Miguel Angel
2015-12-07
The dysfunction of the respiratory system and the breathing complications in persons with injured spinal cord has an effect on the morbidity and the mortality of the disease. The objectives were: 1) to translate to Spanish and validate the questionnaire of international consensus: International Spinal Cord Injury Pulmonary Function Basic Data Set, and 2) to determine the influence of chronic spinal cord injury in the respiratory system in terms of respiratory functionalism. Translation to Spanish and validation of the questionnaire of international consensus intended for the study of the pulmonary function in spinal cord injury disease. We tested the reliability of that questionnaire. We conducted a descriptive transversal study to determine the degree of involvement of the respiratory system in spinal cord injury. A percentage of 91.9 did not have any respiratory pathology before spinal cord injury and 54.8% of patients smoked. A percentage of 27.4 of patients presented breathing complications one year after the injury. Results of the respiratory function tests were: FVC 67%, FEV1 72% and PEF 70%. Concordance and reliability were 98%. The Spanish version of the questionnaire of international consensus about the pulmonary function is a useful tool for the study of the respiratory involvement in spinal cord injury. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.
Washko, George R; Criner, Gerald J; Mohsenifar, Zab; Sciurba, Frank C; Sharafkhaneh, Amir; Make, Barry J; Hoffman, Eric A; Reilly, John J
2008-06-01
Computed tomographic based indices of emphysematous lung destruction may highlight differences in disease pathogenesis and further enable the classification of subjects with Chronic Obstructive Pulmonary Disease. While there are multiple techniques that can be utilized for such radiographic analysis, there is very little published information comparing the performance of these methods in a clinical case series. Our objective was to examine several quantitative and semi-quantitative methods for the assessment of the burden of emphysema apparent on computed tomographic scans and compare their ability to predict lung mechanics and function. Automated densitometric analysis was performed on 1094 computed tomographic scans collected upon enrollment into the National Emphysema Treatment Trial. Trained radiologists performed an additional visual grading of emphysema on high resolution CT scans. Full pulmonary function test results were available for correlation, with a subset of subjects having additional measurements of lung static recoil. There was a wide range of emphysematous lung destruction apparent on the CT scans and univariate correlations to measures of lung function were of modest strength. No single method of CT scan analysis clearly outperformed the rest of the group. Quantification of the burden of emphysematous lung destruction apparent on CT scan is a weak predictor of lung function and mechanics in severe COPD with no uniformly superior method found to perform this analysis. The CT based quantification of emphysema may augment pulmonary function testing in the characterization of COPD by providing complementary phenotypic information.
Thurman, Andrew L; Choi, Jiwoong; Choi, Sanghun; Lin, Ching-Long; Hoffman, Eric A; Lee, Chang Hyun; Chan, Kung-Sik
2017-05-10
Methacholine challenge tests are used to measure changes in pulmonary function that indicate symptoms of asthma. In addition to pulmonary function tests, which measure global changes in pulmonary function, computed tomography images taken at full inspiration before and after administration of methacholine provide local air volume changes (hyper-inflation post methacholine) at individual acinar units, indicating local airway hyperresponsiveness. Some of the acini may have extreme air volume changes relative to the global average, indicating hyperresponsiveness, and those extreme values may occur in clusters. We propose a Gaussian mixture model with a spatial smoothness penalty to improve prediction of hyperresponsive locations that occur in spatial clusters. A simulation study provides evidence that the spatial smoothness penalty improves prediction under different data-generating mechanisms. We apply this method to computed tomography data from Seoul National University Hospital on five healthy and ten asthmatic subjects. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
[Pulmonary reaction after furazidin (Furagin). Case report].
Zielonka, T M; Demkow, U; Kuś, J
1997-05-01
For the first time in Poland we present the case of pulmonary reaction to furazidin which is by chemical structure closely related to nitrofurantoin. 63 years old woman presented generalized symptoms of acute hypersensitivity reaction induced by furazidin as well as features of chronic pulmonary fibrosis. After few months of treatment with this drug patients complained of weight loss, dyspnea on effort, non-productive cough, chills and fever. Radiological and functional evaluation of respiratory system confirmed features of lung fibrosis. Drug provocation test was positive. In vitro furazidin in low concentrations stimulated proliferation of patient's lymphocytes. After cessation of treatment we have observed rapid improvement of clinical, radiological, biochemical and functional parameters.
Camiciottoli, G; Diciotti, S; Bartolucci, M; Orlandi, I; Bigazzi, F; Matucci-Cerinic, M; Pistolesi, M; Mascalchi, M
2013-03-01
Spiral low-dose computed tomography (LDCT) permits to measure whole-lung volume and density in a single breath-hold. To evaluate the agreement between static lung volumes measured with LDCT and pulmonary function test (PFT) and the correlation between the LDCT volumes and lung density in restrictive lung disease. Patients with Systemic Sclerosis (SSc) with (n = 24) and without (n = 16) pulmonary involvement on sequential thin-section CT and patients with chronic obstructive pulmonary disease (COPD)(n = 29) underwent spirometrically-gated LDCT at 90% and 10% of vital capacity to measure inspiratory and expiratory lung volumes and mean lung attenuation (MLA). Total lung capacity and residual volume were measured the same day of CT. Inspiratory [95% limits of agreement (95% LoA)--43.8% and 39.2%] and expiratory (95% LoA -45.8% and 37.1%) lung volumes measured on LDCT and PFT showed poor agreement in SSc patients with pulmonary involvement, whereas they were in substantial agreement (inspiratory 95% LoA -14.1% and 16.1%; expiratory 95% LoA -13.5% and 23%) in SSc patients without pulmonary involvement and in inspiratory scans only (95% LoA -23.1% and 20.9%) of COPD patients. Inspiratory and expiratory LDCT volumes, MLA and their deltas differentiated both SSc patients with or without pulmonary involvement from COPD patients. LDCT lung volumes and density were not correlated in SSc patients with pulmonary involvement, whereas they did correlate in SSc without pulmonary involvement and in COPD patients. In restrictive lung disease due to SSc there is poor agreement between static lung volumes measured using LDCT and PFT and the relationship between volume and density values on CT is altered.
Pulmonary function studies in young healthy Malaysians of Kelantan, Malaysia.
Bandyopadhyay, Amit
2011-11-01
Pulmonary function tests have been evolved as clinical tools in diagnosis, management and follow up of respiratory diseases as it provides objective information about the status of an individual's respiratory system. The present study was aimed to evaluate pulmonary function among the male and female young Kelantanese Malaysians of Kota Bharu, Malaysia, and to compare the data with other populations. A total of 128 (64 males, 64 females) non-smoking healthy young subjects were randomly sampled for the study from the Kelantanese students' population of the University Sains Malaysia, Kota Bharu Campus, Kelantan, Malaysia. The study population (20-25 yr age group) had similar socio-economic background. Each subject filled up the ATS (1978) questionnaire to record their personal demographic data, health status and consent to participate in the study. Subjects with any history of pulmonary diseases were excluded from the study. The pulmonary function measurements exhibited significantly higher values among males than the females. FEV 1% did not show any significant inter-group variation probably because the parameter expresses FEV 1 as a percentage of FVC. FVC and FEV 1 exhibited significant correlations with body height and body mass among males whereas in the females exhibited significant correlation with body mass, body weight and also with age. FEV 1% exhibited significant correlation with body height and body mass among males and with body height in females. FEF 25-75% did not show any significant correlation except with body height among females. However, PEFR exhibited significant positive correlation with all the physical parameters except with age among the females. On the basis of the existence of significant correlation between different physical parameters and pulmonary function variables, simple and multiple regression norms have been computed. From the present investigation it can be concluded that Kelantanese Malaysian youths have normal range of pulmonary function in both the sexes and the computed regression norms may be used to predict the pulmonary function values in the studied population.
Pulmonary function studies in young healthy Malaysians of Kelantan, Malaysia
Bandyopadhyay, Amit
2011-01-01
Background & objectives: Pulmonary function tests have been evolved as clinical tools in diagnosis, management and follow up of respiratory diseases as it provides objective information about the status of an individual's respiratory system. The present study was aimed to evaluate pulmonary function among the male and female young Kelantanese Malaysians of Kota Bharu, Malaysia, and to compare the data with other populations. Methods: A total of 128 (64 males, 64 females) non-smoking healthy young subjects were randomly sampled for the study from the Kelantanese students’ population of the University Sains Malaysia, Kota Bharu Campus, Kelantan, Malaysia. The study population (20-25 yr age group) had similar socio-economic background. Each subject filled up the ATS (1978) questionnaire to record their personal demographic data, health status and consent to participate in the study. Subjects with any history of pulmonary diseases were excluded from the study. Results: The pulmonary function measurements exhibited significantly higher values among males than the females. FEV1% did not show any significant inter-group variation probably because the parameter expresses FEV1 as a percentage of FVC. FVC and FEV1 exhibited significant correlations with body height and body mass among males whereas in the females exhibited significant correlation with body mass, body weight and also with age. FEV1% exhibited significant correlation with body height and body mass among males and with body height in females. FEF25-75% did not show any significant correlation except with body height among females. However, PEFR exhibited significant positive correlation with all the physical parameters except with age among the females. On the basis of the existence of significant correlation between different physical parameters and pulmonary function variables, simple and multiple regression norms have been computed. Interpretation & conclusions: From the present investigation it can be concluded that Kelantanese Malaysian youths have normal range of pulmonary function in both the sexes and the computed regression norms may be used to predict the pulmonary function values in the studied population. PMID:22199104
Arias-Loza, Paula-Anahi; Jung, Pius; Abeßer, Marco; Umbenhauer, Sandra; Williams, Tatjana; Frantz, Stefan; Schuh, Kai; Pelzer, Theo
2016-05-01
Chronic thromboembolic pulmonary hypertension (CTEPH) is an entity of PH that not only limits patients quality of life but also causes significant morbidity and mortality. The treatment of choice is pulmonary endarterectomy. However numerous patients do not qualify for pulmonary endarterectomy or present with residual vasculopathy post pulmonary endarterectomy and require specific vasodilator treatment. Currently, there is no available specific small animal model of CTEPH that could serve as tool to identify targetable molecular pathways and to test new treatment options. Thus, we generated and standardized a rat model that not only resembles functional and histological features of CTEPH but also emulates thrombi fibrosis. The pulmonary embolism protocol consisted of 3 sequential tail vein injections of fibrinogen/collagen-covered polystyrene microspheres combined with thrombin and administered to 10-week-old male Wistar rats. After the third embolism, rats developed characteristic features of CTEPH including elevated right ventricular systolic pressure, right ventricular cardiomyocyte hypertrophy, pulmonary artery remodeling, increased serum brain natriuretic peptide levels, thrombi fibrosis, and formation of pulmonary cellular-fibrotic lesions. The current animal model seems suitable for detailed study of CTEPH pathophysiology and permits preclinical testing of new pharmacological therapies against CTEPH. © 2016 American Heart Association, Inc.
Parvathy, Usha T; Rajan, Rajesh; Faybushevich, Alexander Georgevich
2014-06-01
It is well known that mitral stenosis (MS) is complicated by pulmonary hypertension (PH) of varying degrees. The hemodynamic derangement is associated with structural changes in the pulmonary vessels and parenchyma and also functional derangements. This article analyzes the pulmonary function derangements in 25 patients with isolated/predominant mitral stenosis of varying severity. THE AIM OF THE STUDY WAS TO CORRELATE THE PULMONARY FUNCTION TEST (PFT) DERANGEMENTS (DONE BY SIMPLE METHODS) WITH: a) patient demographics and clinical profile, b) severity of the mitral stenosis, and c) severity of pulmonary artery hypertension (PAH) and d) to evaluate its significance in preoperative assessment. This cross-sectional study was conducted in 25 patients with mitral stenosis who were selected for mitral valve (MV) surgery. The patients were evaluated for clinical class, echocardiographic severity of mitral stenosis and pulmonary hypertension, and with simple methods of assessment of pulmonary function with spirometry and blood gas analysis. The diagnosis and classification were made on standardized criteria. The associations and correlations of parameters, and the difference in groups of severity were analyzed statistically with Statistical Package for Social Sciences (SPSS), using nonparametric measures. THE SPIROMETRIC PARAMETERS SHOWED SIGNIFICANT CORRELATION WITH INCREASING NEW YORK HEART ASSOCIATION (NYHA) FUNCTIONAL CLASS (FC): forced vital capacity (FVC, r = -0.4*, p = 0.04), forced expiratory volume in one second (FEV1, r = -0.5*, p = 0.01), FEV1/FVC (r = -0.44*, p = 0.02), and with pulmonary venous congestion (PVC): FVC (r = -0.41*, p = 0.04) and FEV1 (r = -0.41*, p = 0.04). Cardiothoracic ratio (CTR) correlated only with FEV1 (r = -0.461*, p = 0.02) and peripheral saturation of oxygen (SPO2, r = -0.401*, p = 0.04). There was no linear correlation to duration of symptoms, mitral valve orifice area, or pulmonary hypertension, except for MV gradient with PCO2 (r = 0.594**, p = 0.002). The decreased oxygenation status correlated significantly with FC, CTR, PVC, and with deranged spirometry (r = 0.495*, p = 0.02). PFT derangements are seen in all grades of severity of MS and correlate well with the functional class, though no significant linear correlation with grades of severity of stenosis or pulmonary hypertension. Even the early or mild derangements in pulmonary function such as small airway obstruction in the less severe cases of normal or mild PH can be detected by simple and inexpensive methods when the conventional parameters are normal. The supplementary data from baseline arterial blood gas analysis is informative and relevant. This reclassified pulmonary function status might be prognostically predictive.
Moullec, G; Ninot, G
2010-02-01
To assess whether a maintenance integrated health care programme is effective in improving functional and emotional dimensions of quality of life in patients with chronic obstructive pulmonary disease (COPD) after a first pulmonary rehabilitation. Prospective controlled trial. Three rehabilitation centres and three patient self-help associations within a health care network in France. Forty patients with moderate to severe COPD. After a first four-week inpatient pulmonary rehabilitation programme, patients took part in a maintenance integrated health care programme or usual care for 12 months. The primary outcomes were the change in functional and emotional dimensions of quality of life measured by the St George's Respiratory Questionnaire (SGRQ), the brief World Health Organization Quality of Life questionnaire (Brief-WHOQOL) and six specific questions using a 10-cm visual analogue scale. Secondary outcomes were change in exercise tolerance measured by six-minute walking test and cycle exercise. At one year, the maintenance intervention (n = 11) produced improvements in functional and emotional dimensions scores of quality of life and exercise tolerance. Patients in the usual aftercare group (n = 16) exhibited maintenance of functional dimension scores of quality of life, but a clinically relevant decline in emotional scores of quality of life and in six-minute walking distance one year after the pulmonary rehabilitation. Patient self-help association seems to be an innovative and efficient organizational structure to support patients with COPD after pulmonary rehabilitation in real-life settings. A distinction between emotional and functional dimensions of quality of life may improve the design and evaluation of integrated health care programmes in patients with COPD.
Ohno, Yoshiharu; Yoshikawa, Takeshi; Takenaka, Daisuke; Fujisawa, Yasuko; Sugihara, Naoki; Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro
2017-01-01
To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) MATERIALS AND METHODS: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7±8.7years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV 1 . Each inter-observer agreement was rated as substantial (Sub-CT: κ=0.69, p<0.0001; DE-CT: κ=0.64, p<0.0001; SPECT/CT: κ=0.64, p<0.0001). Functional lung volume for each method showed significant to good correlation with%FEV 1 (Sub-CT: r=0.72, p=0.0001; DE-CT: r=0.74, p<0.0001; SPECT/CT: r=0.66, p=0.0006). Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Lung Function in Pregnancy in Langerhans Cell Histiocytosis.
Radzikowska, Elżbieta; Wiatr, Elżbieta; Franczuk, Monika; Bestry, Iwona; Roszkowski-Śliż, Kazimierz
2018-01-01
Pulmonary Langerhans cell histiocytosis (LCH) is a rare disease, affecting usually young people. The course of the disease is variable. In some pulmonary LCH patients a severe lung destruction and progression in spite of chemotherapy is observed, but in others just a cessation of smoking induces a regression of the disease. In the present study we seek to determine the influence of pregnancy on pulmonary function in LCH patients, an unchartered area of research. We addressed the issue by investigating eight pregnant women out of the 45 women hospitalized with the diagnosis of pulmonary LCH in the period from 2000 to 2015. For five of the eight pregnant women it was the second gestation. The median follow-up period was 120 months (range 72-175 months). Ten healthy children were born by a C-section. Two spontaneous miscarriages in the seventh week of gestation, and one tubal ectopic pregnancy were recorded. We found that pregnancy did not significantly influence pulmonary function assessed by the following indices: forced expiratory volume in 1 s (FEV1), lung vital capacity (VC), total lung capacity (TLC), residual volume (RV), diffusing capacity of the lungs for carbon monoxide (DLCO), and the distance and arterial oxygen saturation in 6-min walk test. Only one patient in the third trimester of pregnancy experienced bilateral pneumothorax, with persistent air leak. In all patients, delivery and postpartum period were uneventful. We conclude that pregnancy in pulmonary LCH patients is safe and not associated with deterioration of pulmonary function or blood oxygenation.
Humphries, Stephen M; Yagihashi, Kunihiro; Huckleberry, Jason; Rho, Byung-Hak; Schroeder, Joyce D; Strand, Matthew; Schwarz, Marvin I; Flaherty, Kevin R; Kazerooni, Ella A; van Beek, Edwin J R; Lynch, David A
2017-10-01
Purpose To evaluate associations between pulmonary function and both quantitative analysis and visual assessment of thin-section computed tomography (CT) images at baseline and at 15-month follow-up in subjects with idiopathic pulmonary fibrosis (IPF). Materials and Methods This retrospective analysis of preexisting anonymized data, collected prospectively between 2007 and 2013 in a HIPAA-compliant study, was exempt from additional institutional review board approval. The extent of lung fibrosis at baseline inspiratory chest CT in 280 subjects enrolled in the IPF Network was evaluated. Visual analysis was performed by using a semiquantitative scoring system. Computer-based quantitative analysis included CT histogram-based measurements and a data-driven textural analysis (DTA). Follow-up CT images in 72 of these subjects were also analyzed. Univariate comparisons were performed by using Spearman rank correlation. Multivariate and longitudinal analyses were performed by using a linear mixed model approach, in which models were compared by using asymptotic χ 2 tests. Results At baseline, all CT-derived measures showed moderate significant correlation (P < .001) with pulmonary function. At follow-up CT, changes in DTA scores showed significant correlation with changes in both forced vital capacity percentage predicted (ρ = -0.41, P < .001) and diffusing capacity for carbon monoxide percentage predicted (ρ = -0.40, P < .001). Asymptotic χ 2 tests showed that inclusion of DTA score significantly improved fit of both baseline and longitudinal linear mixed models in the prediction of pulmonary function (P < .001 for both). Conclusion When compared with semiquantitative visual assessment and CT histogram-based measurements, DTA score provides additional information that can be used to predict diminished function. Automatic quantification of lung fibrosis at CT yields an index of severity that correlates with visual assessment and functional change in subjects with IPF. © RSNA, 2017.
Supomo, Supomo; Darmawan, Handy; Arjana, Adika Zhulhi
2018-05-22
The presence of altered pulmonary hemodynamics in adult patients with atrial septal defect (ASD) is common. However, there are no observational studies which evaluate the impact of altered pulmonary hemodynamics on the 6-min walk test (6MWT) result. This study aimed to investigate the role of pulmonary hemodynamics in determining 6MWT result of patients with ASD. Forty-six consecutive adult patients with ASD were included in this study. Right heart catheterization was performed to obtain the pulmonary hemodynamics profile. Meanwhile, 6MWT was presented as high or low with cut-off point 350 m. Receiver operating characteristic (ROC) was used for analytical methods. Abnormal functional capacity was indicated by ROC result of mPAP cut-off value of > 24 mmHg (p = 0.0243; AUC = 0.681). The value of PVR > 3.42 woods unit (WU) showed high specificity in determining abnormal functional capacity (p = 0.0069; AUC = 0.713). Flow ratio with cut-off point ≤4.89 had the highest sensitivity (100%) (p = 0.8300; AUC = 0.520). Pulmonary hemodynamics can serve as an indicator of 6MWT result in adult ASD patients with values of mPAP> 24 mmHg and PVR > 3.42 WU.
Borges, Daniel L; Silva, Mayara Gabrielle; Silva, Luan Nascimento; Fortes, João Vyctor; Costa, Erika Thalita; Assunção, Rebeca Pessoa; Lima, Carlos Magno; da Silva Nina, Vinícius José; Bernardo-Filho, Mário; Caputo, Danúbia Sá
2016-09-01
Physical activity is beneficial in several clinical situations and recommended for patients with ischemic heart disease, as well as for those undergoing cardiac surgery. In a randomized controlled trial, 34 patients underwent coronary artery bypass grafting. A randomized control group (n = 15) submitted to conventional physiotherapy. The intervention group (n = 19) received the same protocol plus additional aerobic exercise with cycle ergometer. Pulmonary function by spirometry, respiratory muscle strength by manovacuometry, and functional capacity through 6-minute walking test was assessed before surgery and at hospital discharge. There was significant reduction in pulmonary function in both groups. In both groups, inspiratory muscle strength was maintained while expiratory muscle strength significantly decreased. Functional capacity was maintained in the intervention group (364.5 [324.5 to 428] vs. 348 [300.7 to 413.7] meters, P = .06), but it decreased significantly in control group patients (320 [288.5 to 393.0] vs. 292 [237.0 to 336.0] meters, P = .01). A significant difference in functional capacity was also found in intergroup analyses at hospital discharge (P = .03). Aerobic exercise applied early on coronary artery bypass grafting patients may promote maintenance of functional capacity, with no impact on pulmonary function and respiratory muscle strength when compared with conventional physiotherapy.
Fibroblast growth factor 10 haploinsufficiency causes chronic obstructive pulmonary disease.
Klar, Joakim; Blomstrand, Peter; Brunmark, Charlott; Badhai, Jitendra; Håkansson, Hanna Falk; Brange, Charlotte Sollie; Bergendal, Birgitta; Dahl, Niklas
2011-10-01
Genetic factors influencing lung function may predispose to chronic obstructive pulmonary disease (COPD). The fibroblast growth factor 10 (FGF10) signalling pathway is critical for lung development and lung epithelial renewal. The hypothesis behind this study was that constitutive FGF10 insufficiency may lead to pulmonary disorder. Therefore investigation of the pulmonary functions of patients heterozygous for loss of function mutations in the FGF10 gene was performed. The spirometric measures of lung function from patients and non-carrier siblings were compared and both groups were related to matched reference data for normal human lung function. The patients show a significant decrease in lung function parameters when compared to control values. The average FEV1/IVC quota (FEV1%) for the patients is 0.65 (80% of predicted) and reversibility test using Terbutalin resulted in a 3.7% increase in FEV1. Patients with FGF10 haploinsufficiency have lung function parameters indicating COPD. A modest response to Terbutalin confirms an irreversible obstructive lung disease. These findings support the idea that genetic variants affecting the FGF10 signalling pathway are important determinants of lung function that may ultimately contribute to COPD. Specifically, the results show that FGF10 haploinsufficiency affects lung function measures providing a model for a dosage sensitive effect of FGF10 in the development of COPD.
Astronaut David Wolf in medical experiment in SLS-2
NASA Technical Reports Server (NTRS)
1993-01-01
Astronaut David A. Wolf, mission specialist, participates in an experiment that investigates in-space distribution and movement of blood and gas in the pulmonary system. The data gathered during the two-week flight will be compared with results of tests performed on Earth to determine the changes that occur in pulmonary functions.
Heydari, Abbas; Farzad, Marjan; Ahmadi hosseini, Seyed-hossein
2015-01-01
To examine the effect of incentive spirometry in pulmonary rehabilitation of chronic obstructive pulmonary disease (COPD) patients and compare its efficacy with inspiratory resistive muscle training (IMT) technique. Randomized controlled trial. Thirty patients with COPD, from a general hospital in Mashhad, Iran, were randomly assigned to two study groups. All subjects trained daily in two 15-minute sessions, 4 days a week, for 4 weeks. Respiratory function tests were compared before interventions and at the end of weeks 2 and 4. Both techniques improved the mean values of all respiratory function tests (p≤.01). The IMT technique was more effective to improve MVV and PImax (p≤.05). PEFR was better improved in the incentive spirometry group (p≤.05). There was no significant difference for other spirometric parameters between two groups. Incentive spirometry can be considered as an effective component for pulmonary rehabilitation in COPD patients. © 2013 Association of Rehabilitation Nurses.
Pulmonary Function Testing in Children
... breathing test. About 15 minutes after taking the medicine, your child will repeat the breathing test. The results from ... the first test to find out if the medicine has improved your child’s breathing. Why shouldn’t I give my child ...
Influence of pulmonary emphysema on COPD assessment test-oriented categorization in GOLD document.
Suzuki, Toshio; Tada, Yuji; Kawata, Naoko; Ikari, Jun; Kasahara, Yasunori; Sakurai, Yoriko; Iesato, Ken; Nishimura, Rintaro; West, James; Tatsumi, Koichiro
2015-01-01
The COPD assessment test (CAT) score is a key component of the multifactorial assessment of COPD in the Global initiative for chronic Obstructive Lung Disease (GOLD) guidelines of 2014. Nevertheless, little is known regarding the differences among COPD categories in terms of clinical parameters such as pulmonary function or radiological findings. Thus, our aims in this study were to evaluate the associations between CAT scores and pulmonary clinical parameters, and to investigate factors that could discriminate between a "less symptomatic group" (categories A and C) and a "more symptomatic group" (categories B and D) among stable COPD patients. We enrolled 200 outpatients at Chiba University Hospital. Study subjects were assessed by CAT, pulmonary function testing, and multidetector computed tomography (MDCT). We assessed possible correlations between these indices. CAT scores were negatively correlated with percentage of the forced expiratory volume in 1 second predicted value (FEV1 %predicted) and percentage of the diffusing capacity for carbon monoxide per liter of lung volume predicted value (DLCO/VA [%predicted]) results and positively correlated with low attenuation volume percentage (LAV%) and residual volume to total lung capacity ratios (RV/TLC). In the "more symptomatic group" (category B or D), the mean DLCO/VA (%predicted) was significantly lower and the mean LAV% and RV/TLC was significantly higher than those in the "less symptomatic group" (category A or C), respectively. Interestingly, those in category B had higher mean LAV% compared to those in category C. CAT scores were significantly correlated with pulmonary function parameters and emphysematous changes on MDCT. The new GOLD classification system would be a step toward a phenotypic approach, especially taking into account the degree of emphysema and hyperinflation.
Nikolaidis, Lazaros; Memon, Nabeel; O'Murchu, Brian
2015-02-01
We describe the case of a 54-year-old man who presented with exertional dyspnea and fatigue that had worsened over the preceding 2 years, despite a normally functioning bioprosthetic aortic valve and stable, mild left ventricular dysfunction (left ventricular ejection fraction, 0.45). His symptoms could not be explained by physical examination, an extensive biochemical profile, or multiple cardiac and pulmonary investigations. However, abnormal cardiopulmonary exercise test results and a right heart catheterization-combined with the use of a symptom-limited, bedside bicycle ergometer-revealed that the patient's exercise-induced pulmonary artery hypertension was out of proportion to his compensated left heart disease. A trial of sildenafil therapy resulted in objective improvements in hemodynamic values and functional class.
Moreira, Fabiana B R; de Fuccio, Marcelo B; Ribeiro-Samora, Giane Amorim; Velloso, Marcelo
2018-05-01
Chronic obstructive pulmonary disease reduces functional capacity, which is strongly correlated with the morbidity and mortality of patients. The BODE index considers the multifactorial nature of the disease, including the functional capacity measured by the 6-min walk test (6MWT), and this index predicts the mortality in patients with chronic obstructive pulmonary disease. Our aim was to assess whether association exists between the original BODE index and the modified BODE index by replacing the 6MWT with the scores from the Pulmonary Functional Status and Dyspnea Questionnaire-Modified version (PFSDQ-M), Human Activity Profile (HAP) questionnaire, and the results of the Glittre ADL Test (TGlittre). Twenty-eight subjects diagnosed with chronic obstructive pulmonary disease underwent the 6MWT and TGlittre and responded to the PFSDQ-M and HAP questionnaires. Four BODE index scores were obtained: 1 calculated by using the original method (ie, using the 6MWT) and 3 others calculated by using the results obtained from the TGlittre, PFSDQ-M, and HAP (the modified BODE index scores). High levels of association were observed between the original BODE index and the BODE TGlittre (R = 0.824, P ≤ .0001), BODE PFSDQ-M (R = 0.803, P ≤ .0001), and BODE HAP (R = 0.500, P ≤ .0001). The BODE TGlittre, and BODE PFSDQ-M may be used as alternatives to the 6MWT when physical space is not available to perform the 6MWT or when the condition of a patient does not allow performance of the 6MWT.
Arefnasab, Zahra; Ghanei, Mostafa; Noorbala, Ahmad Ali; Alipour, Ahmad; Babamahmoodi, Farhang; Babamahmoodi, Abdolreza; Salehi, Maryam
2013-09-01
Studies have shown that Mindfulness Based Stress Reduction (MBSR) has positive effect on physical and psychological dimensions of chronic illnesses. In this study for the first time we examine the effect of this new technique on quality of life and pulmonary function in chemically pulmonary injured veterans who have chronic pulmonary problem, psychological problems and low quality of life. Forty male pulmonary injured veterans were randomly replaced in two groups with 20 participants (MBSR and control Wait List (WL)). Then MBSR group received 8-weekly sessions intervention. We evaluate quality of life (used SF-36 questionnaire) and Spirometry parameters two times; before and after intervention in two group. We used "mixed factorial analyses of variance" test for analyzing data in each dependent variables. Then if we have significant interactional effect, we used -paired- sample t-test" for comparing before and after intervention data of each group, and "Independent-Sample t-test" for comparing after intervention data of two groups. The MBSR compare to WL group improved SF-36 total score, (F (1, 38) =12.09, P=0.001), "Role limitations due to physical problems"(F(1,38)= 6.92, P=0.01), "Role limitations due to emotional problems"(F(1,38)= 7.75, P=0.008), "Social functioning"(F(1,38)= 9.89, P=0.003), "Mental health"(F(1,38)= 15.93, P=0), "Vitality"(F(1,38)= 40.03, P≤0.001), and "Pain"(F(1,38)= 27.60, P≤0.001). MBSR had no significant effect on "FEV1" (F (1, 38) = 0.03, P=0.85),"FVC" (F (1, 38) = 0.16, P=0.69) and "FEV1/FVC" (F (1, 38) = 2.21, P=0.14). MBSR can improve individual's quality of life but not lung function in chemically pulmonary injured veterans.
Macke, Ryan A; Schuchert, Matthew J; Odell, David D; Wilson, David O; Luketich, James D; Landreneau, Rodney J
2015-04-01
A suggested benefit of sublobar resection for stage I non-small cell lung cancer (NSCLC) compared to lobectomy is a relative preservation of pulmonary function. Very little objective data exist, however, supporting this supposition. We sought to evaluate the relative impact of both anatomic segmental and lobar resection on pulmonary function in patients with resected clinical stage I NSCLC. The records of 159 disease-free patients who underwent anatomic segmentectomy (n = 89) and lobectomy (n = 70) for the treatment of stage I NSCLC with pre- and postoperative pulmonary function tests performed between 6 to 36 months after resection were retrospectively reviewed. Changes in forced expiratory volume in one second (FEV1) and diffusion capacity of carbon monoxide (DLCO) were analyzed based upon the number of anatomic pulmonary segments removed: 1-2 segments (n = 77) or 3-5 segments (n = 82). Preoperative pulmonary function was worse in the lesser resection cohort (1-2 segments) compared to the greater resection group (3-5 segments) (FEV1(%predicted): 79% vs. 85%, p = 0.038; DLCO(%predicted): 63% vs. 73%, p = 0.010). A greater decline in FEV1 was noted in patients undergoing resection of 3-5 segments (FEV1 (observed): 0.1 L vs. 0.3 L, p = 0.003; and FEV1 (% predicted): 4.3% vs. 8.2%, p = 0.055). Changes in DLCO followed this same trend (DLCO(observed): 1.3 vs. 2.4 mL/min/mmHg, p = 0.015; and DLCO(% predicted): 3.6% vs. 5.9%, p = 0.280). Parenchymal-sparing resections resulted in better preservation of pulmonary function at a median of one year, suggesting a long-term functional benefit with small anatomic segmental resections (1-2 segments). Prospective studies to evaluate measurable functional changes, as well as quality of life, between segmentectomy and lobectomy with a larger patient cohort appear justified.
Heathcote, Karen L; Cockcroft, Donald W; Fladeland, Derek A; Fenton, Mark E
2011-01-01
Pulmonary function tests in patients with idiopathic pulmonary fibrosis characteristically show a restrictive pattern including small lung volumes and increased expiratory flow rates resulting from a reduction in pulmonary compliance due to diffuse fibrosis. Conversely, an obstructive pattern with hyperinflation results in emphysema by loss of elastic recoil, expiratory collapse of the peripheral airways and air trapping. When the diseases coexist, pulmonary volumes are compensated, and a smaller than expected reduction or even normal lung volumes can be found. The present report describes 10 patients with progressive breathlessness, three of whom experienced severe limitation in their quality of life. All patients showed lung interstitial involvement and emphysema on computed tomography scan of the chest. The 10 patients showed normal spirometry and lung volumes with severe compromise of gas exchange. Normal lung volumes do not exclude diagnosis of idiopathic pulmonary fibrosis in patients with concomitant emphysema. The relatively preserved lung volumes may underestimate the severity of idiopathic pulmonary fibrosis and attenuate its effects on lung function parameters.
Koulouri, Agoritsa; Gourgoulianis, Konstantinos; Hatzoglou, Chryssi; Roupa, Zoe
2014-01-01
ABSTRACT Introduction: Chronic Obstructive Pulmonary Disease (COPD) has a significant impact on quality of life-related health. Aim: It was the detection of Chronic Obstructive Pulmonary Disease by using telemetric methods and the investigation of the quality of life for people working in Shipbuilding Industry compared with a control group. Methods: A group of one hundred men working in the shipbuilding industry aged 51.8 ± 8.2 years old and a control group of one hundred men of the general population aged 51.1 ± 6.4 years were studied. All participants completed the General Health Questionnaire – 28, the Fagerstrom test and a form with demographic characteristics. Pulmonary function test results were electronically sent to a specialist for evaluation. Results: People working in the shipbuilding zone had significantly lower values (p<0.001) in FVC, FEV1 and FEV1/FVC compared with the general population participants. Worse social functionality was exhibited by workers in the shipbuilding zone, people with elementary education, unemployed and by those suffering from comorbidities (p <0.001). Conclusions: Health level and its individual dimensions are both associated with health self-assessment and occupational and economic status. The coexistence of chronic diseases and smoking dependence affects emotion and social functioning of individuals. PMID:25568580
Koulouri, Agoritsa; Gourgoulianis, Konstantinos; Hatzoglou, Chryssi; Roupa, Zoe
2014-10-01
Chronic Obstructive Pulmonary Disease (COPD) has a significant impact on quality of life-related health. It was the detection of Chronic Obstructive Pulmonary Disease by using telemetric methods and the investigation of the quality of life for people working in Shipbuilding Industry compared with a control group. A group of one hundred men working in the shipbuilding industry aged 51.8 ± 8.2 years old and a control group of one hundred men of the general population aged 51.1 ± 6.4 years were studied. All participants completed the General Health Questionnaire - 28, the Fagerstrom test and a form with demographic characteristics. Pulmonary function test results were electronically sent to a specialist for evaluation. People working in the shipbuilding zone had significantly lower values (p<0.001) in FVC, FEV1 and FEV1/FVC compared with the general population participants. Worse social functionality was exhibited by workers in the shipbuilding zone, people with elementary education, unemployed and by those suffering from comorbidities (p <0.001). Health level and its individual dimensions are both associated with health self-assessment and occupational and economic status. The coexistence of chronic diseases and smoking dependence affects emotion and social functioning of individuals.
Arteta, Manuel; Campbell, Andrew; Nouraie, Mehdi; Rana, Sohail; Onyekwere, Onyinye; Ensing, Gregory; Sable, Craig; Dham, Niti; Darbari, Deepika; Luchtman-Jones, Lori; Kato, Gregory J.; Gladwin, Mark T.; Castro, Oswaldo L.; Minniti, Caterina P.; Gordeuk, Victor R.
2015-01-01
Obstructive and restrictive pulmonary changes develop in children with sickle cell disease, but reports conflict as to the type of change that predominates. We prospectively performed spirometry, plethysmography and lung diffusing capacity in 146 children aged 7–20 years with hemoglobin SS or Sβ0-thalassemia. Nineteen percent of the patients had obstructive physiology as defined according to guidelines of the American Thoracic Society. In addition, 9% had restrictive physiology and 11% had abnormal but not categorized physiology. Increasing age, patient- or family-reported history of asthma or wheezing, and higher lactate dehydrogenase concentration were independent predictors of obstruction as reflected in lower FEV1/FVC. In conclusion, abnormal pulmonary function, most often obstructive, is common in children with hemoglobin SS and Sβ0-thalassemia. Full pulmonary function testing should be performed in children with hemoglobin SS or Sβ0 thalassemia, especially with history of asthma or wheezing and accentuated elevations in hemolytic markers. PMID:24309610
One year efficacy and safety of oral sildenafil treatment in severe pulmonary hypertension.
Samarzija, Miroslav; Zuljević, Ervin; Jakopović, Marko; Sever, Branko; Knezević, Aleksandar; Dumija, Zeljko; Vidjak, Vinko; Samija, Mirko
2009-09-01
Severe pulmonary hypertension is a progressive disease which leads to limitations of functional status and poor survival. We evaluated efficacy and safety of a short (3 months) and a long term (12 months) sildenafil treatment in patients with severe pulmonary hypertension. We treated 12 patients with pulmonary hypertension with oral sildenafil. Patients were followed at three time points, at baseline, and after 3 and 12 months of treatment. Primary end point was improvement in functional exercise capacity assesed by 6-minute walk test, and secondary end points were changes in right ventricle hemodynamics. We found significant improvement in 6-minute walk test distance from 357 +/- 193 m at baseline to 431 +/- 179 m after three months and further improvement to 501 +/- 159 m after 12 months (p < 0.01); decrease in right ventricule pressure from 107 +/- 42 mmHg at baseline to 87 +/- 32 mmHg after 12 months (p < 0.01); and, decrease in right ventricule diameter from 3.2 +/- 1.1 cm to 2.76 +/- 0.86 cm after twelve months (p < 0.01). Drug-related adverse events were mild and transient in our group of patients. Long-term (12 months) sildenafil treatment is effective and safe in our patients with idiopathic and chronic thrombo-embolic pulmonary hypertension.
20 CFR 718.103 - Pulmonary function tests.
Code of Federal Regulations, 2010 CFR
2010-04-01
... of the forced expiratory volume in one second (FEV1) and the forced vital capacity (FVC). The report..., noncomplying tests may form the basis for a finding if, in the opinion of the adjudication officer, the tests...
20 CFR 718.103 - Pulmonary function tests.
Code of Federal Regulations, 2011 CFR
2011-04-01
... of the forced expiratory volume in one second (FEV1) and the forced vital capacity (FVC). The report..., noncomplying tests may form the basis for a finding if, in the opinion of the adjudication officer, the tests...
20 CFR 718.103 - Pulmonary function tests.
Code of Federal Regulations, 2013 CFR
2013-04-01
... of the forced expiratory volume in one second (FEV1) and the forced vital capacity (FVC). The report..., noncomplying tests may form the basis for a finding if, in the opinion of the adjudication officer, the tests...
20 CFR 718.103 - Pulmonary function tests.
Code of Federal Regulations, 2012 CFR
2012-04-01
... of the forced expiratory volume in one second (FEV1) and the forced vital capacity (FVC). The report..., noncomplying tests may form the basis for a finding if, in the opinion of the adjudication officer, the tests...
20 CFR 718.103 - Pulmonary function tests.
Code of Federal Regulations, 2014 CFR
2014-04-01
... of the forced expiratory volume in one second (FEV1) and the forced vital capacity (FVC). The report..., noncomplying tests may form the basis for a finding if, in the opinion of the adjudication officer, the tests...
... heavily for at least 30 minutes before the test. ■■ Do not wear tight clothing that makes it difficult for you ... be blowing into a tube connected to a machine (spirometer). To get the “best” test result, the test is repeated three times. You ...
Progressive ventilation inhomogeneity in infants with cystic fibrosis after pulmonary infection.
Simpson, Shannon J; Ranganathan, Sarath; Park, Judy; Turkovic, Lidija; Robins-Browne, Roy M; Skoric, Billy; Ramsey, Kathryn A; Rosenow, Tim; Banton, Georgia L; Berry, Luke; Stick, Stephen M; Hall, Graham L
2015-12-01
Measures of ventilation distribution are promising for monitoring early lung disease in cystic fibrosis (CF). This study describes the cross-sectional and longitudinal impacts of pulmonary inflammation and infection on ventilation homogeneity in infants with CF.Infants diagnosed with CF underwent multiple breath washout (MBW) testing and bronchoalveolar lavage at three time points during the first 2 years of life.Measures were obtained for 108 infants on 156 occasions. Infants with a significant pulmonary infection at the time of MBW showed increases in lung clearance index (LCI) of 0.400 units (95% CI 0.150-0.648; p=0.002). The impact was long lasting, with previous pulmonary infection leading to increased ventilation inhomogeneity over time compared to those who remained free of infection (p<0.05). Infection with Haemophilus influenzae was particularly detrimental to the longitudinal lung function in young children with CF where LCI was increased by 1.069 units for each year of life (95% CI 0.484-1.612; p<0.001).Pulmonary infection during the first year of life is detrimental to later lung function. Therefore, strategies aimed at prevention, surveillance and eradication of pulmonary pathogens are paramount to preserve lung function in infants with CF. Copyright ©ERS 2015.
Pulmonary function test findings in patients with acute inhalation injury caused by smoke bombs
Cao, Lu; Zhang, Xin-Gang; Wang, Jian-Guo; Wang, Han-Bin; Chen, Yi-Bing; Zhao, Da-Hui; Shi, Wen-Fang
2016-01-01
Background This study aimed to determine the effects of smoke bomb-induced acute inhalation injury on pulmonary function at different stages of lung injury. Methods We performed pulmonary function tests (PFTs) in 15 patients with acute inhalation injury from days 3 to 180 after smoke inhalation. We measured the trace element zinc in whole blood on days 4 and 17, and correlations of zinc levels with PFTs were performed. Results In the acute stage of lung injury (day 3), 3 of 11 patients with mild symptoms had normal pulmonary function and 8 patients with restrictive ventilatory dysfunction and reduced diffusing capacity. Some patients also had mild obstructive ventilatory dysfunction (5 patients) and a decline in small airway function (6 patients). For patients with severe symptoms, PFT results showed moderate to severe restrictive ventilatory dysfunction and reduced diffusing capacity. PaCO2 was significantly higher (P=0.047) in patients with reduced small airway function compared with those with normal small airway function. Whole blood zinc levels in the convalescence stage (day 17) were significantly lower than those in the acute stage (day 4). Zinc in the acute stage was negatively correlated with DLCO/VA on days 3, 10, and 46 (r=−0.633, −0.676, and −0.675 respectively, P<0.05). Conclusions Smoke inhalation injury mainly causes restrictive ventilatory dysfunction and reduced diffusing capacity, and causes mild obstructive ventilatory dysfunction and small airway function decline in some patients. Zinc is negatively correlated with DLCO/VA. Zinc levels may be able to predict prognosis and indicate the degree of lung injury. PMID:28066595
Lung Function Measurements in Rodents in Safety Pharmacology Studies
Hoymann, Heinz Gerd
2012-01-01
The ICH guideline S7A requires safety pharmacology tests including measurements of pulmonary function. In the first step – as part of the “core battery” – lung function tests in conscious animals are requested. If potential adverse effects raise concern for human safety, these should be explored in a second step as a “follow-up study”. For these two stages of safety pharmacology testing, both non-invasive and invasive techniques are needed which should be as precise and reliable as possible. A short overview of typical in vivo measurement techniques is given, their advantages and disadvantages are discussed and out of these the non-invasive head-out body plethysmography and the invasive but repeatable body plethysmography in orotracheally intubated rodents are presented in detail. For validation purposes the changes in the respective parameters such as tidal midexpiratory flow (EF50) or lung resistance have been recorded in the same animals in typical bronchoconstriction models and compared. In addition, the technique of head-out body plethysmography has been shown to be useful to measure lung function in juvenile rats starting from day two of age. This allows safety pharmacology testing and toxicological studies in juvenile animals as a model for the young developing organism as requested by the regulatory authorities (e.g., EMEA Guideline 1/2008). It is concluded that both invasive and non-invasive pulmonary function tests are capable of detecting effects and alterations on the respiratory system with different selectivity and area of operation. The use of both techniques in a large number of studies in mice and rats in the last years have demonstrated that they provide useful and reliable information on pulmonary mechanics in safety pharmacology and toxicology testing, in investigations of respiratory disorders, and in pharmacological efficacy studies. PMID:22973226
... exhale, and how quickly you exhale, spirometry can evaluate a broad range of lung diseases. In a ... expiratory volume in 1 second (FEV1) Forced expiratory flow 25% to 75% (FEF25-75) Functional residual capacity ( ...
Gutiérrez-Delgado, R I; Barraza-Villarreal, A; Escamilla-Núñez, C; Hernández-Cadena, L; Garcia-Feregrino, R; Shackleton, C; Ramakrishnan, U; Sly, P D; Romieu, I
2018-04-04
Prenatal omega-3 fatty acids improve alveolarization, diminish inflammation, and improve pulmonary growth, but it is unclear whether these outcomes translate into improved postnatal lung function. We assessed the effect of prenatal supplementation with docosahexaenoic acid (DHA) on offspring lung function through 60 months of age. We included a cohort of 772 Mexican preschoolers whose mothers participated in a clinical trial (NCT00646360) of supplementation with DHA or a placebo from week 18-22 of gestation through delivery. The children were followed after birth and anthropometric measurements and forced oscillation tests were performed at 36, 48, and 60 months of age. The effect of DHA was tested using a longitudinal mixed effect models. Overall, mean (Standard Deviation) of the measurements of respiratory system resistance and respiratory system reactance at 6, 8, and 10 Hz during follow up period were 11.3 (2.4), 11.1 (2.4), 10.3 (2.2) and -5.2 (1.6), -4.8 (1.7), -4.6 (1.6), respectively. There were no significant differences in pulmonary function by treatment group. DHA did not affect the average lung function or the trajectories through 60 months. Prenatal DHA supplementation did not influence pulmonary function in this cohort of Mexican preschoolers.
Miller, Albert; Warshaw, Raphael; Nezamis, James
2013-12-01
Asbestosis is an interstitial lung disease whose radiographic severity has long been graded by the International Labour Office (ILO) profusion score. Its effect on pulmonary function is further impacted by asbestos related pleural thickening. This report aims to describe the relationships between radiographic grading of interstitial and pleural fibrosis and a key test of pulmonary function, the diffusing capacity, which measures gas exchange and has rarely been assessed in large groups, and to confirm the relationship to an independent test of pulmonary function, the vital capacity, which measures a mechanical property of the lungs. The data were derived from a survey during the period 1997-2004 of 5,003 workers (all white males) exposed to asbestos in various trades. Tests included chest radiographs read by a certified expert ("B") reader, forced vital capacity (FVC), and carbon monoxide diffusing capacity (DLco). Cigarette smoking was adjusted for in the predictive equation for DLCO . Workers were evaluated at a mobile facility at work sites in four southern states. Both diffusing capacity and vital capacity were negatively correlated with profusion score over the full spectrum of radiographic severity. ILO profusion scores 0/1 (conventionally classified as normal) and 1/0 (conventionally classified as abnormal) were associated with similar diffusing capacity and vital capacity values. The highest profusion scores were associated with a greater proportionate decrease in diffusing capacity than in FVC. Both tests showed an effect of pleural fibrosis. Both radiographic severity graded by the profusion score and pleural thickening are correlated with two independent measures of pulmonary function. FVC (which had been reported in smaller work forces) and DLCO (which has not been reported). Both measures show a decrease from normal to intermediate (0/1, 1/0) scores and a further decrease with greater scores, demonstrating the consistency of radiographic and functional assessments. © 2013 Wiley Periodicals, Inc.
Bandera, Francesco; Generati, Greta; Pellegrino, Marta; Donghi, Valeria; Alfonzetti, Eleonora; Gaeta, Maddalena; Villani, Simona; Guazzi, Marco
2014-09-01
Several cardiovascular diseases are characterized by an impaired O2 kinetic during exercise. The lack of a linear increase of Δoxygen consumption (VO2)/ΔWork Rate (WR) relationship, as assessed by expired gas analysis, is considered an indicator of abnormal cardiovascular efficiency. We aimed at describing the frequency of ΔVO2/ΔWR flattening in a symptomatic population of cardiac patients, characterizing its functional profile, and testing the hypothesis that dynamic pulmonary hypertension and right ventricular contractile reserve play a major role as cardiac determinants. We studied 136 patients, with different cardiovascular diseases, referred for exertional dyspnoea. Cardiopulmonary exercise test combined with simultaneous exercise echocardiography was performed using a symptom-limited protocol. ΔVO2/ΔWR flattening was observed in 36 patients (group A, 26.5% of population) and was associated with a globally worse functional profile (reduced peak VO2, anaerobic threshold, O2 pulse, impaired VE/VCO2). At univariate analysis, exercise ejection fraction, exercise mitral regurgitation, rest and exercise tricuspid annular plane systolic excursion, exercise systolic pulmonary artery pressure, and exercise cardiac output were all significantly (P<0.05) impaired in group A. The multivariate analysis identified exercise systolic pulmonary artery pressure (odds ratio, 1.06; confidence interval, 1.01-1.11; P=0.01) and exercise tricuspid annular plane systolic excursion (odds ratio, 0.88; confidence interval, 0.80-0.97; P=0.01) as main cardiac determinants of ΔVO2/ΔWR flattening; female sex was strongly associated (odds ratio, 6.10; confidence interval, 2.11-17.7; P<0.01). In patients symptomatic for dyspnea, the occurrence of ΔVO2/ΔWR flattening reflects a significantly impaired functional phenotype whose main cardiac determinants are the excessive systolic pulmonary artery pressure increase and the reduced peak right ventricular longitudinal systolic function. © 2014 American Heart Association, Inc.
Disturbances of Pulmonary Function in Mitral Valve Disease
Palmer, Wilfred H.; Gee, J. B. L.; Mills, F. C.; Bates, D. V.
1963-01-01
To study the sequence of changes in respiratory function that occur in the natural history of mitral stenosis, and the physiological basis of “cardiac dyspnea”, 30 patients with chronic mitral valve disease were subjected to detailed pulmonary function tests. There was no significant change in vital capacity and functional residual capacity. The reduction in maximal mid-expiratory flow rate showed excellent correlation with the respiratory symptoms. The pulmonary capillary blood volume was increased in moderately advanced cases but was consistently reduced in the severest cases. Hyperventilation was due to an increased respiratory rate. Dyspnea was associated with increased respiratory work owing to the interrelation between the reduction in diffusion capacity, compliance, cardiac output, the increase in airway resistance, and the uneven ventilation and perfusion of the lungs. The amount of “effort” required to breathe is incommensurate with the external load in these patients. PMID:14060164
Choi, Ho-Chun; Son, Ki Young; Cho, Belong; Park, Sang Min; Cho, Sung-Il
2012-01-01
If association between the decline in physical performance and the decline in pulmonary function is confirmed, the SPPB could be used as a predictor for pulmonary functional declines in aging people because of its convenient use. This study aimed to elucidate the association of the SPPB with the pulmonary function test (PFT) to determine the usefulness of the SPPB as a predictor of PFT decline. The SPPB and PFT were performed on random sample nested in the Korean Longitudinal Study of Aging (KLoSA) panel, a national representative sample of aging people in Korea. Comparisons of adjusted means of forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), forced expiratory ratio (FER) defined as FEV1/FVC between normal and abnormal SPPB groups were performed using the t-test. The association between PFT and SPPB abnormality was examined using multiple logistic regression analysis. Additionally, the associations of gait speed and chair stand time with FEV1 and FVC were examined using multiple linear regression analysis. Five hundred and eighteen subjects were included in analysis. Approximately 43% (222/518) of the subjects were male and 65% (338/518) were 60 years or older. Adjusted means of FEV1 and FER were significantly or marginally lower when SPPB score was abnormal in both overall and non-smoking men (p=0.009 and 0.053 for overall, p<0.001 and p<0.080 for non-smokers), but FVC was lower only in non-smoking men (p=0.024). Abnormal SPPB score was significantly associated with abnormal PFT regardless of sex. (adjusted odds ratio=OR=3.76, 95%CI=1.96-7.22 for men, adjusted OR=2.11, 95%CI 1.28-3.47 for women). Gait speed was significantly or marginally associated with FEV1 and FVC in participants 60 years or older, regardless of sex. We conclude that abnormal SPPB score was associated with abnormal pulmonary function. Thus, the SPPB has the potential to be used as an early predictor of abnormal pulmonary function in clinical settings and epidemiological study. Copyright © 2011. Published by Elsevier Ireland Ltd.
Ohno, Yoshiharu; Koyama, Hisanobu; Yoshikawa, Takeshi; Matsumoto, Keiko; Takahashi, Masaya; Van Cauteren, Marc; Sugimura, Kazuro
2011-08-01
The purpose of this study was to determine the usefulness of MRI with ultrashort TEs on a 3-T system and of thin-section MDCT for pulmonary function assessment and clinical stage classification of chronic obstructive pulmonary disease (COPD) in smokers. Forty smokers (24 men and 16 women; mean age ± SD, 68.0 ± 9.3 years) underwent MRI with ultrashort TEs and thin-section MDCT. Pulmonary function testing was also performed to determine the following: the ratio of forced expiratory volume in 1 second to forced vital capacity (percentage predicted) (FEV(1/)FVC%), percentage predicted forced expiratory volume in 1 second (%FEV(1)), and percentage predicted diffusing capacity of lung for carbon monoxide corrected for alveolar volume (%DLCO/V(A)). All subjects were classified into one of four groups as follows: smokers without COPD, with mild COPD, with moderate COPD, and with severe or very severe COPD. T2(*) maps were expressed using proprietary software. Regional T2(*) values were determined by region of interest measurements and were averaged to determine a mean T2(*) value for each subject. CT-based functional lung volume and the ratio of the wall area to the total airway area were also determined. All indexes were statistically correlated with pulmonary function parameters. Then, all indexes were compared among all groups by means of Tukey's honest significance test. All indexes had significant correlation with FEV(1)/FVC%, %FEV(1), and % DLCO/V(A) (p < 0.05). All indexes except WA% of smokers without COPD and smokers with mild COPD differed significantly from those of smokers with moderate COPD and smokers with severe or very severe COPD (p < 0.05). Moreover, the mean T2(*) value of the moderate COPD group was significantly different from that of the severe or very severe COPD group (p < 0.05). MRI with ultrashort TEs is potentially as useful as quantitatively assessed MDCT for pulmonary function loss assessment and clinical stage classification of COPD in smokers.
Jacob, Joseph; Bartholmai, Brian J; Rajagopalan, Srinivasan; Kokosi, Maria; Nair, Arjun; Karwoski, Ronald; Raghunath, Sushravya M; Walsh, Simon L F; Wells, Athol U; Hansell, David M
2016-09-01
The aim of the study was to determine whether a novel computed tomography (CT) postprocessing software technique (CALIPER) is superior to visual CT scoring as judged by functional correlations in idiopathic pulmonary fibrosis (IPF). A total of 283 consecutive patients with IPF had CT parenchymal patterns evaluated quantitatively with CALIPER and by visual scoring. These 2 techniques were evaluated against: forced expiratory volume in 1 second (FEV1), forced vital capacity (FVC), diffusing capacity for carbon monoxide (DLco), carbon monoxide transfer coefficient (Kco), and a composite physiological index (CPI), with regard to extent of interstitial lung disease (ILD), extent of emphysema, and pulmonary vascular abnormalities. CALIPER-derived estimates of ILD extent demonstrated stronger univariate correlations than visual scores for most pulmonary function tests (PFTs): (FEV1: CALIPER R=0.29, visual R=0.18; FVC: CALIPER R=0.41, visual R=0.27; DLco: CALIPER R=0.31, visual R=0.35; CPI: CALIPER R=0.48, visual R=0.44). Correlations between CT measures of emphysema extent and PFTs were weak and did not differ significantly between CALIPER and visual scoring. Intriguingly, the pulmonary vessel volume provided similar correlations to total ILD extent scored by CALIPER for FVC, DLco, and CPI (FVC: R=0.45; DLco: R=0.34; CPI: R=0.53). CALIPER was superior to visual scoring as validated by functional correlations with PFTs. The pulmonary vessel volume, a novel CALIPER CT parameter with no visual scoring equivalent, has the potential to be a CT feature in the assessment of patients with IPF and requires further exploration.
Oki, Hiroshi; Yazawa, Takuya; Baba, Yasuko; Kanegae, Yumi; Sato, Hanako; Sakamoto, Seiko; Goto, Takahisa; Saito, Izumu; Kurahashi, Kiyoyasu
2017-07-01
Pulmonary emphysema impairs quality of life and increases mortality. It has previously been shown that administration of adenovirus vector expressing murine keratinocyte growth factor (KGF) before elastase instillation prevents pulmonary emphysema in mice. We therefore hypothesized that therapeutic administration of KGF would restore damage to lungs caused by elastase instillation and thus improve pulmonary function in an animal model. KGF expressing adenovirus vector, which prevented bleomycin-induced pulmonary fibrosis in a previous study, was constructed. Adenovirus vector (1.0 × 10 9 plaque-forming units) was administered intratracheally one week after administration of elastase into mouse lungs. One week after administration of KGF-vector, exercise tolerance testing and blood gas analysis were performed, after which the lungs were removed under deep anesthesia. KGF-positive pneumocytes were more numerous, surfactant protein secretion in the airspace greater and mean linear intercept of lungs shorter in animals that had received KGF than in control animals. Unexpectedly, however, arterial blood oxygenation was worse in the KGF group and maximum running speed, an indicator of exercise capacity, had not improved after KGF in mice with elastase-induced emphysema, indicating that KGF-expressing adenovirus vector impaired pulmonary function in these mice. Notably, vector lacking KGF-expression unit did not induce such impairment, implying that the KGF expression unit itself may cause the damage to alveolar cells. Possible involvement of the CAG promoter used for KGF expression in impairing pulmonary function is discussed. © 2017 The Societies and John Wiley & Sons Australia, Ltd.
Jeans, Kelly A; Lovejoy, John F; Karol, Lori A; McClung, Anna M
2017-11-01
Prospectively enrolled AIS patients who underwent spinal fusion, with 2 year follow-up. To evaluate the cardiovascular fitness and activity level in patients with AIS pre- and post-spinal fusion and to determine if initial curve magnitude or pulmonary function is predictive of exercise capacity. Researchers have tried to link pulmonary function testing (PFT) to exercise capacity; the results are mixed. Some report no improvement in PFTs or aerobic activity after surgical correction, and PFT measures were not predictive of exercise capacity. Conflicting results have shown Vo 2max results to fall within normal range in AIS patients while PFTs show minimal impairment. AIS patients underwent PFT and oxygen consumption (VO 2 ) testing during a submaximal graded exercise test (GXT) pre- and post-spinal fusion. Vo 2max was predicted in those patients who completed the test to 85% of maximal heart rate. Pre- to postoperative changes were assessed and then compared to age-matched control subjects. Correlations between Vo 2max and curve severity, pulmonary function, and activity level were assessed. Thirty-seven patients participated. Vo 2max was predicted in 23 patients pre- and postoperation. There was a significant reduction in Vo 2max postfusion (39.5 ± 6.5 mL/kg/min vs 42.1 ± 8.1 mL/kg/min, p = .033); however, compared with controls (40.5 ± 6.5 mL/kg/min), all data were within the normal range (p > .05). AIS patients reporting high activity had significantly greater Vo 2max than those reporting low activity both pre and postoperatively, but this difference only met statistical significance preop (p < .05). Curve magnitude and PFT measures were not found to correlate with Vo 2max (p > .05). Vo 2max in patients with AIS is within normal range both pre- and postfusion. Pulmonary limitations are accommodated for with a slightly increased breathing rate and a slightly reduced overall workload. Activity level rather than curve severity affects Vo 2max outcomes following fusion in AIS. Copyright © 2017 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.
Study of adrenal function in patients with tuberculosis.
Sarin, Bipan Chander; Sibia, Keerat; Kukreja, Sahiba
2018-07-01
Although subclinical adrenal insufficiency has been documented in tuberculosis but it has been neglected in mainstream management of TB due to inconclusive data on its prevalence in TB. The fact that adrenal insufficiency may result not only in poor general condition of the patient but also sudden death due to adrenal crisis, makes it all the more important to address this issue seriously. In this non-randomized interventional study comprising of 100 cases of TB, our aim was to assess the adreno-cortical functions in patients with pulmonary TB (50 cases) and extra-pulmonary TB (50 cases) in an attempt to determine if there is any compromise of adrenal function. In this study, 100 cases of active TB were investigated for adrenal insufficiency by measuring morning fasting basal serum cortisol levels, followed by low dose ACTH stimulation test using 1μg synacthen (synthetic ACTH analog). The post-stimulation serum cortisol levels were estimated. Basal serum cortisol levels<220nmol/L or post-stimulation test serum cortisol level increment<200nmol/L or post-stimulation serum cortisol levels<500nmol/L were suggestive of adrenal insufficiency. Basal serum cortisol level was low in 16% cases and after low dose ACTH stimulation test, cortisol response was subnormal in 76% cases. Incidence of adrenal insufficiency in pulmonary TB (74%) and extra-pulmonary TB (78%) were comparable. The number of females having adrenal insufficiency in both the groups was higher than the males (67.3% males and 83.3% females) but the difference was statistically significant only in extra-pulmonary TB group (p=0.011). On analysing the data, the sensitivity of basal serum cortisol level estimation in diagnosing adrenal insufficiency was observed to be 21.05% and its specificity was 100%. Positive predictive value was 100% and negative predictive value was 28.57%. Diagnostic accuracy of basal serum cortisol level estimation was observed to be 40%. The incidence of subclinical adrenal insufficiency in TB cases attending chest department at a tertiary care hospital was significantly high but comparable in both pulmonary and extra-pulmonary type of TB. Females in general and particularly those with extra-pulmonary TB were observed to be at increased risk of adrenal insufficiency. The low dose ACTH stimulation test was able to identify cases with adrenal insufficiency which had normal basal serum cortisol levels. Screening all TB cases for adrenal insufficiency by measuring both morning basal serum cortisol levels and low dose ACTH stimulation test can help identify cases at risk of fatal adrenal crisis and institute timely management, thus improving disease prognosis. Copyright © 2017 Tuberculosis Association of India. Published by Elsevier B.V. All rights reserved.
Step climbing capacity in patients with pulmonary hypertension.
Fox, Benjamin Daniel; Langleben, David; Hirsch, Andrew; Boutet, Kim; Shimony, Avi
2013-01-01
Patients with pulmonary hypertension (PH) typically have exercise intolerance and limitation in climbing steps. To explore the exercise physiology of step climbing in PH patients, on a laboratory-based step test. We built a step oximetry system from an 'aerobics' step equipped with pressure sensors and pulse oximeter linked to a computer. Subjects mounted and dismounted from the step until their maximal exercise capacity or 200 steps was achieved. Step-count, SpO(2) and heart rate were monitored throughout exercise and recovery. We derived indices of exercise performance, desaturation and heart rate. A 6-min walk test and serum NT-proBrain Natriuretic Peptide (BNP) level were measured. Lung function tests and hemodynamic parameters were extracted from the medical record. Eighty-six subjects [52 pulmonary arterial hypertension (PAH), 14 chronic thromboembolic PH (CTEPH), 20 controls] were recruited. Exercise performance (climbing time, height gained, velocity, energy expenditure, work-rate and climbing index) on the step test was significantly worse with PH and/or worsening WHO functional class (ANOVA, p < 0.001). There was a good correlation between exercise performance on the step and 6-min walking distance-climb index (r = -0.77, p < 0.0001). The saturation deviation (mean of SpO(2) values <95 %) on the step test correlated with diffusion capacity of the lung (ρ = -0.49, p = 0.001). No correlations were found between the step test indices and other lung function tests, hemodynamic parameters or NT-proBNP levels. Patients with PAH/CTEPH have significant limitation in step climbing ability that correlates with functional class and 6-min walking distance. This is a significant impediment to their daily activities.
Pulmonary function in infectious mononucleosis.
Morgan, E J; Altmeyer, R; Khakoo, R; Lapp, N L
1982-06-01
Infectious mononucleosis (IM) is common among students. These patients often complain of fatigue and dyspnea. To determine whether IM alters respiratory function, we performed spirometric, single-breath diffusing capacity, and maximal static respiratory pressure tests on seven patients with symptoms of IM. These studies were repeated two weeks later and the respiratory pressures were repeated five months later. Each patient served as his own control. Pulmonary function was normal except for respiratory pressures, which were initially low. These pressures, still low after two weeks, improved significantly after five months. We concluded that IM is associated with transient respiratory muscle weakness.
Mechanics of cryopreserved aortic and pulmonary homografts.
Vesely, I; Casarotto, D C; Gerosa, G
2000-01-01
The surgical placement of pulmonary valve grafts into the aortic position (the Ross procedure) has been performed for three decades. Cryopreserved pulmonary valves have had mixed clinical results, however. The objectives of this study were to compare the mechanics of cryopreserved human aortic and pulmonary valve cusps and roots to determine if the pulmonary root can withstand the greater pressures of the aortic position. Six aortic and six pulmonary valve roots were obtained from the Oxford Valve Bank. They were harvested during cardiac transplantation from hearts explanted for dilated cardiomyopathy (mean patient age 68 years). The whole roots were initially stored frozen at -186 degrees C, then shipped packed on dry ice. After complete thawing, the roots were pressurized whole; test strips were then cut from the valve cusps, roots and sinuses and tested for stress/strain, stress relaxation, and ultimate failure strength. The pulmonary roots were more distensible (30% versus 20% strain to lock-up) and less compliant when loaded to aortic pressures. The pulmonary valve cusp and root tissue also showed greater extensibility and greater stiffness (lower compliance) when subjected to the same loads. We conclude that mechanical differences between aortic and pulmonary valve tissues are minimal. The pulmonary root should withstand the forces imposed on it when placed in the aortic position. However, if implanted whole, the pulmonary root will distend about 30% more than the aortic root when subjected to aortic pressures. These geometric changes may affect valve function in the long term and should be appreciated when implanting a pulmonary valve graft.
Wiessmann, K J
1975-09-05
The effects on pulmonary function of a slow-release preparation of an oral broncholytic drug (containing 350 mg aminophylline, released over eight hours) was tested on 26 patients in a double-blind trial. There was a marked reduction of airway resistance and stimulation of breathing with decreased dynamic work of breathing. Distinctly improved alveolar function was demonstrated especially in a fall of arterial CO2 tension, but in some cases there was probably an increase in distribution abnormality. Central haemodynamic changes with a decreased in pulmonary artery pressure and changes in the other values lasted for more than ten hours on the first day of treatment, and were demonstrable on the fourth day even before the drug was taken that day. The criteria of an effective broncholytic slow-release drug with sustained effect were thus fulfilled.
Pulmonary vascular function and exercise capacity in black sub-Saharan Africans.
Simaga, Bamodi; Vicenzi, Marco; Faoro, Vitalie; Caravita, Sergio; Di Marco, Giovanni; Forton, Kevin; Deboeck, Gael; Lalande, Sophie; Naeije, Robert
2015-09-01
Sex and age affect the pulmonary circulation. Whether there may be racial differences in pulmonary vascular function is unknown. Thirty white European Caucasian subjects (15 women) and age and body-size matched 30 black sub-Saharan African subjects (15 women) underwent a cardiopulmonary exercise test and exercise stress echocardiography with measurements of pulmonary artery pressure (PAP) and cardiac output (CO). A pulmonary vascular distensibility coefficient α was mathematically determined from the natural curvilinearity of multipoint mean PAP (mPAP)-CO plots. Maximum oxygen uptake (V̇o2max) and workload were higher in the whites, while maximum respiratory exchange ratio and ventilatory equivalents for CO2 were the same. Pulmonary hemodynamics were not different at rest. Exercise was associated with a higher maximum total pulmonary vascular resistance, steeper mPAP-CO relationships, and lower α-coefficients in the blacks. These differences were entirely driven by higher slopes of mPAP-CO relationships (2.5 ± 0.7 vs. 1.4 ± 0.7 mmHg·l(-1)·min; P < 0.001) and lower α-coefficients (0.85 ± 0.33 vs. 1.35 ± 0.51%/mmHg; P < 0.01) in black men compared with white men. There were no differences in any of the hemodynamic variables between black and white women. In men only, the slopes of mPAP-CO relationships were inversely correlated to V̇o2max (P < 0.01). Thus the pulmonary circulation is intrinsically less distensible in black sub-Saharan African men compared with white Caucasian Europeans men, and this is associated with a lower exercise capacity. This study did not identify racial differences in pulmonary vascular function in women. Copyright © 2015 the American Physiological Society.
Pulmonary Function, Muscle Strength, and Incident Mobility Disability in Elders
Buchman, Aron S.; Boyle, Patricia A.; Leurgans, Sue E.; Evans, Denis A.; Bennett, David A.
2009-01-01
Muscle strength, including leg strength and respiratory muscle strength, are relatively independently associated with mobility disability in elders. However, the factors linking muscle strength with mobility disability are unknown. To test the hypothesis that pulmonary function mediates the association of muscle strength with the development of mobility disability in elders, we used data from a longitudinal cohort study of 844 ambulatory elders without dementia participating in the Rush Memory and Aging Project with a mean follow-up of 4.0 years (SD = 1.39). A composite measure of pulmonary function was based on spirometric measures of forced vital capacity, forced expiratory volume, and peak expiratory flow. Respiratory muscle strength was based on maximal inspiratory pressure and expiratory pressure and leg strength based on hand-held dynamometry. Mobility disability was defined as a gait speed less than or equal to 0.55 m/s based on annual assessment of timed walk. Secondary analyses considered time to loss of the ability to ambulate. In separate proportional hazards models which controlled for age, sex, and education, composite measures of pulmonary function, respiratory muscle strength, and leg strength were each associated with incident mobility disability (all P values < 0.001). Further, all three were related to the development of incident mobility disability when considered together in a single model (pulmonary function: hazard ratio [HR], 0.721; 95% confidence interval [CI], 0.577, 0.902; respiratory muscle strength: HR, 0.732; 95% CI, 0.593, 0.905; leg strength: HR, 0.791; 95% CI, 0.640, 0.976). Secondary analyses examining incident loss of the ability to ambulate revealed similar findings. Overall, these findings suggest that lower levels of pulmonary function and muscle strength are relatively independently associated with the development of mobility disability in the elderly. PMID:19934353
Nonlinear model for offline correction of pulmonary waveform generators.
Reynolds, Jeffrey S; Stemple, Kimberly J; Petsko, Raymond A; Ebeling, Thomas R; Frazer, David G
2002-12-01
Pulmonary waveform generators consisting of motor-driven piston pumps are frequently used to test respiratory-function equipment such as spirometers and peak expiratory flow (PEF) meters. Gas compression within these generators can produce significant distortion of the output flow-time profile. A nonlinear model of the generator was developed along with a method to compensate for gas compression when testing pulmonary function equipment. The model and correction procedure were tested on an Assess Full Range PEF meter and a Micro DiaryCard PEF meter. The tests were performed using the 26 American Thoracic Society standard flow-time waveforms as the target flow profiles. Without correction, the pump loaded with the higher resistance Assess meter resulted in ten waveforms having a mean square error (MSE) higher than 0.001 L2/s2. Correction of the pump for these ten waveforms resulted in a mean decrease in MSE of 87.0%. When loaded with the Micro DiaryCard meter, the uncorrected pump outputs included six waveforms with MSE higher than 0.001 L2/s2. Pump corrections for these six waveforms resulted in a mean decrease in MSE of 58.4%.
Effects of High-Flux versus Low-Flux Membranes on Pulmonary Function Tests in Hemodialysis Patients.
Momeni, Ali; Rouhi, Hamid; Kiani, Glareh; Amiri, Masoud
2013-01-01
Several studies have been carried out to evaluate the effects of dialysis on pulmonary function tests (PFT). Dialysis procedure may reduce lung volumes and capacities or cause hypoxia; however, to the best of our knowledge, there is no previous study evaluating the effects of membrane type (high flux vs. low flux) on PFT in these patients. The aim of this study was the evaluation of this relationship. In this cross-sectional study, 43 hemodialysis patients without pulmonary disease were enrolled. In these patients dialysis was conducted by low-and high-flux membranes and before and after the procedure, spirometry was done and the results were evaluated by t-test and chi square test. The mean age of patients was 56.34 years. Twenty-three of them were female (53.5%). Type of membrane (high flux vs. low flux) had no effect on spirometry results of patients despite the significant decrease in the body weight during the dialysis session. High flux membrane had no advantage over low flux membrane in terms of improvement in spirometry findings; thus, we could not offer these expensive membranes for this purpose.
Influence of radiological emphysema on lung function test in idiopathic pulmonary fibrosis.
Bodlet, Aline; Maury, Gisèle; Jamart, Jacques; Dahlqvist, Caroline
2013-11-01
Idiopathic pulmonary fibrosis (IPF) is one of the most frequent interstitial lung disease. Emphysema can be associated with IPF as described in the «Combined pulmonary fibrosis and emphysema» syndrome. The primary endpoint of this retrospective cohort study was to evaluate the impact of the association of IPF and emphysema on lung function tests parameters (FVC, TLC, FEV1, FEV1/FVC and DLCO). The secondary endpoint was to assess the impact of the associated radiological emphysema on lung function parameters used in the du Bois prognostic score recently developed by Ron du Bois et al. We retrospectively reviewed the medical files of 98 patients with lung fibrosis who were followed in our University Hospital with access to pharmacological studies and lung transplantation from 1981 to 2011. Fifty six patients were considered for analysis. The collected data included gender, age, smoking history and respiratory hospitalizations. We also analysed their pulmonary functional parameters along with radiological characteristics, in particular the presence of emphysema which was assessed on thoracic high resolution CT scan. The du Bois score was retrospectively calculated from these data. TLC and FVC at diagnosis were significantly higher in the IPF-E group compared to the IPF group (respectively 86.6 ± 17.2% pv versus 72.0 ± 15.0% pv; p: 0.004 and 86.8 ± 18.4% pv versus 72.6 ± 20.6% pv; p: 0.020). The [Formula: see text] used in the calculation of the du Bois prognostic score was significantly higher in the IPF-E group. By cons, [Formula: see text] was not statistically different between the two groups. Radiological emphysema associated with IPF had an impact on pulmonary function tests. Despite this difference, the du Bois score was not statistically different between these two groups. Nevertheless, after one year of follow up, the patients with emphysema were in a subclass with a lower mortality rate than those without emphysema. Copyright © 2013 Elsevier Ltd. All rights reserved.
Impaired lung function in individuals chronically exposed to biomass combustion.
da Silva, Luiz Fernando Ferraz; Saldiva, Silvia Regina Dias Médici; Saldiva, Paulo Hilário Nascimento; Dolhnikoff, Marisa
2012-01-01
The use of biomass for cooking and heating is considered an important factor associated with respiratory diseases. However, few studies evaluate the amount of particulate matter less than 2.5 μm in diameter (PM2.5), symptoms and lung function in the same population. To evaluate the respiratory effects of biomass combustion and compare the results with those of individuals from the same community in Brazil using liquefied petroleum gas (Gas). 1402 individuals in 260 residences were divided into three groups according to exposure (Gas, Indoor-Biomass, Outside-Biomass). Respiratory symptoms were assessed using questionnaires. Reflectance of paper filters was used to assess particulate matter exposure. In 48 residences the amount of PM2.5 was also quantified. Pulmonary function tests were performed in 120 individuals. Reflectance index correlated directly with PM2.5 (r=0.92) and was used to estimate exposure (ePM2.5). There was a significant increase in ePM2.5 in Indoor-Biomass and Outside-Biomass, compared to Gas. There was a significantly increased odds ratio (OR) for cough, wheezing and dyspnea in adults exposed to Indoor-Biomass (OR=2.93, 2.33, 2.59, respectively) and Outside-Biomass (OR=1.78, 1.78, 1.80, respectively) compared to Gas. Pulmonary function tests revealed both Non-Smoker-Biomass and Smoker-Gas individuals to have decreased %predicted-forced expiratory volume in the first second (FEV1) and FEV1/forced vital capacity (FVC) as compared to Non-Smoker-Gas. Pulmonary function tests data was inversely correlated with duration and ePM2.5. The prevalence of airway obstruction was 20% in both Non-Smoker-Biomass and Smoker-Gas subjects. Chronic exposure to biomass combustion is associated with increased prevalence of respiratory symptoms, reduced lung function and development of chronic obstructive pulmonary disease. These effects are associated with the duration and magnitude of exposure and are exacerbated by tobacco smoke. Copyright © 2011 Elsevier Inc. All rights reserved.
Do patients with mild to moderate psoriasis really have a sedentary lifestyle?
Demirel, Reha; Genc, Abdurrahman; Ucok, Kagan; Kacar, Seval Dogruk; Ozuguz, Pinar; Toktas, Muhsin; Sener, Umit; Karabacak, Hatice; Karaca, Semsettin
2013-09-01
The aim of this study was to compare aerobic exercise capacity, daily physical activity, pulmonary functions, resting metabolic rate, and body composition parameters in patients with psoriasis and healthy controls. A total of 60 participants (30 [15 men, 15 women] patients with psoriasis, and 30 [15 men, 15 women] healthy controls) ranging in age from 22-57 were included in the study. Maximal aerobic capacity was determined by Astrand exercise protocol. Daily physical activity was measured with an accelerometer. Resting metabolic rate was determined with an indirect calorimeter. Pulmonary function tests were performed with a portable spirometer. Body composition was established with a bioelectric impedance analysis system. Skinfold thicknesses and body circumference measurements were carried out. Short Form 36 quality of life questionnaire was applied to all participants. In both genders, daily physical activity parameters were found to be higher in the psoriasis group compared to the control. Maximal aerobic capacity, resting metabolic rate, pulmonary function tests, body fatness, body fat distributions, and quality of life were not statistically different between patients with psoriasis and controls in males and females. We suggest that patients with psoriasis who do not have psoriatic arthritis or severe psoriasis are well in performing daily physical activities. In addition, we suggest that this lifestyle helped to prevent impairments of body fatness, body fat distributions, resting metabolic rate, pulmonary functions, and quality of life in patients with mild to moderate psoriasis. © 2013 The International Society of Dermatology.
Effects of dynamic hyperinflation on exercise capacity and quality of life in stable COPD patients.
Zhao, Li; Peng, Liyue; Wu, Baomei; Bu, Xiaoning; Wang, Chen
2016-09-01
Dynamic hyperinflation (DH) is an important pathophysiological characteristic of chronic obstructive pulmonary disease (COPD). There is increasing evidence that DH has negative effects on exercise performance and quality of life. The objective of this study was to explore effects of DH on exercise capacity and quality of life in stable COPD patients. Fifty-eight COPD patients and 20 matched healthy individuals underwent pulmonary function test, 6-min walk test and symptom-limited cardiopulmonary exercise test (CPET). End-expiratory lung volume/total lung capacity ratio (EELVmax/TLC) at peak exercise of CPET was evaluated, and EELVmax/TLC ≥ 75% was defined as 'severe dynamic hyperinflation (SDH)'. Of the 58 patients studied, 29 (50.0%) presented with SDH (SDH+ group, EELVmax/TLC 79.60 ± 3.60%), having worse maximal exercise capacity reflected by lower peakload, maximal oxygen uptake (VO2 max), maximal carbon dioxide output (VCO2 max) and maximal minute ventilation (VEmax) than did those without SDH (SDH- group, EELVmax/TLC 67.44 ± 6.53%). The EELVmax/TLC ratio at peak exercise had no association with variables of pulmonary function and 6-min walk distance (6MWD), but correlated inversely with peakload, VO2 max, VCO2 max and VEmax (r = -0.300~-0.351, P < 0.05). Although no significant differences were observed, patients with EELVmax/TLC ≥ 75% tended to have higher COPD assessment test score (15.07 ± 6.55 vs 13.28 ± 6.59, P = 0.303). DH develops variably during exercise and has a greater impact on maximal exercise capacity than 6MWD, even in those with the same extent of pulmonary function impairment at rest. © 2015 John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Venkatramani, Rajkumar, E-mail: rvenkatramani@chla.usc.edu; Department of Pediatrics, Keck School of Medicine, University of Southern California, Los Angeles, California; Kamath, Sunil
Purpose: To identify the incidence and the risk factors for pulmonary toxicity in children treated for cancer with contemporary lung irradiation. Methods and Materials: We analyzed clinical features, radiographic findings, pulmonary function tests, and dosimetric parameters of children receiving irradiation to the lung fields over a 10-year period. Results: We identified 109 patients (75 male patients). The median age at irradiation was 13.8 years (range, 0.04-20.9 years). The median follow-up period was 3.4 years. The median prescribed radiation dose was 21 Gy (range, 0.4-64.8 Gy). Pulmonary toxic chemotherapy included bleomycin in 58.7% of patients and cyclophosphamide in 83.5%. The followingmore » pulmonary outcomes were identified and the 5-year cumulative incidence after irradiation was determined: pneumonitis, 6%; chronic cough, 10%; pneumonia, 35%; dyspnea, 11%; supplemental oxygen requirement, 2%; radiographic interstitial lung disease, 40%; and chest wall deformity, 12%. One patient died of progressive respiratory failure. Post-irradiation pulmonary function tests available from 44 patients showed evidence of obstructive lung disease (25%), restrictive disease (11%), hyperinflation (32%), and abnormal diffusion capacity (12%). Thoracic surgery, bleomycin, age, mean lung irradiation dose (MLD), maximum lung dose, prescribed dose, and dosimetric parameters between V{sub 22} (volume of lung exposed to a radiation dose ≥22 Gy) and V{sub 30} (volume of lung exposed to a radiation dose ≥30 Gy) were significant for the development of adverse pulmonary outcomes on univariate analysis. MLD, maximum lung dose, and V{sub dose} (percentage of volume of lung receiving the threshold dose or greater) were highly correlated. On multivariate analysis, MLD was the sole significant predictor of adverse pulmonary outcome (P=.01). Conclusions: Significant pulmonary dysfunction occurs in children receiving lung irradiation by contemporary techniques. MLD rather than prescribed dose should be used to perform risk stratification of patients receiving lung irradiation.« less
Infection, inflammation, and lung function decline in infants with cystic fibrosis.
Pillarisetti, Naveen; Williamson, Elizabeth; Linnane, Barry; Skoric, Billy; Robertson, Colin F; Robinson, Phil; Massie, John; Hall, Graham L; Sly, Peter; Stick, Stephen; Ranganathan, Sarath
2011-07-01
Better understanding of evolution of lung function in infants with cystic fibrosis (CF) and its association with pulmonary inflammation and infection is crucial in informing both early intervention studies aimed at limiting lung damage and the role of lung function as outcomes in such studies. To describe longitudinal change in lung function in infants with CF and its association with pulmonary infection and inflammation. Infants diagnosed after newborn screening or clinical presentation were recruited prospectively. FVC, forced expiratory volume in 0.5 seconds (FEV(0.5)), and forced expiratory flows at 75% of exhaled vital capacity (FEF(75)) were measured using the raised-volume technique, and z-scores were calculated from published reference equations. Pulmonary infection and inflammation were measured in bronchoalveolar lavage within 48 hours of lung function testing. Thirty-seven infants had at least two successful repeat lung function measurements. Mean (SD) z-scores for FVC were -0.8 (1.0), -0.9 (1.1), and -1.7 (1.2) when measured at the first visit, 1-year visit, or 2-year visit, respectively. Mean (SD) z-scores for FEV(0.5) were -1.4 (1.2), -2.4 (1.1), and -4.3 (1.6), respectively. In those infants in whom free neutrophil elastase was detected, FVC z-scores were 0.81 lower (P=0.003), and FEV(0.5) z-scores 0.96 lower (P=0.001), respectively. Significantly greater decline in FEV(0.5) z-scores occurred in those infected with Staphylococcus aureus (P=0.018) or Pseudomonas aeruginosa (P=0.021). In infants with CF, pulmonary inflammation is associated with lower lung function, whereas pulmonary infection is associated with a greater rate of decline in lung function. Strategies targeting pulmonary inflammation and infection are required to prevent early decline in lung function in infants with CF.
Hataji, Osamu; Nishii, Yoichi; Ito, Kentaro; Sakaguchi, Tadashi; Saiki, Haruko; Suzuki, Yuta; D'Alessandro-Gabazza, Corina; Fujimoto, Hajime; Kobayashi, Tetsu; Gabazza, Esteban C.; Taguchi, Osamu
2017-01-01
Combined therapy with tiotropium and olodaterol notably improves parameters of lung function and quality of life in patients with chronic obstructive pulmonary disease (COPD) compared to mono-components; however, its effect on physical activity is unknown. The present study evaluated whether combination therapy affects daily physical performance in patients with COPD under a smart watch-based encouragement program. This was a non-blinded clinical trial with no randomization or placebo control. A total of 20 patients with COPD were enrolled in the present study. The patients carried an accelerometer for 4 weeks; they received no therapy during the first 2 weeks but they were treated with combined tiotropium and olodaterol under a smart watch-based encouragement program for the last 2 weeks. The pulmonary function test, COPD assessment test, 6-min walk distance and parameters of physical activity were significantly improved (P<0.05) by combination therapy under smart watch-based coaching compared with values prior to treatment. To the best of our knowledge, the present study for the first time provides evidence that smart watch-based coaching in combination with tiotropium and olodaterol may improve daily physical activity in chronic obstructive pulmonary disease. PMID:29104624
Hataji, Osamu; Nishii, Yoichi; Ito, Kentaro; Sakaguchi, Tadashi; Saiki, Haruko; Suzuki, Yuta; D'Alessandro-Gabazza, Corina; Fujimoto, Hajime; Kobayashi, Tetsu; Gabazza, Esteban C; Taguchi, Osamu
2017-11-01
Combined therapy with tiotropium and olodaterol notably improves parameters of lung function and quality of life in patients with chronic obstructive pulmonary disease (COPD) compared to mono-components; however, its effect on physical activity is unknown. The present study evaluated whether combination therapy affects daily physical performance in patients with COPD under a smart watch-based encouragement program. This was a non-blinded clinical trial with no randomization or placebo control. A total of 20 patients with COPD were enrolled in the present study. The patients carried an accelerometer for 4 weeks; they received no therapy during the first 2 weeks but they were treated with combined tiotropium and olodaterol under a smart watch-based encouragement program for the last 2 weeks. The pulmonary function test, COPD assessment test, 6-min walk distance and parameters of physical activity were significantly improved (P<0.05) by combination therapy under smart watch-based coaching compared with values prior to treatment. To the best of our knowledge, the present study for the first time provides evidence that smart watch-based coaching in combination with tiotropium and olodaterol may improve daily physical activity in chronic obstructive pulmonary disease.
Nevel, Rebekah J.; Garnett, Errine T.; Worrell, John A.; Morton, Ronald L.; Nogee, Lawrence M.; Blackwell, Timothy S.
2016-01-01
Rationale: Neuroendocrine cell hyperplasia of infancy (NEHI) is a diffuse lung disease that presents in infancy and improves during childhood. Long-term outcomes have not previously been described. In one familial cohort, we have reported that NEHI is associated with a heterozygous variant of NKX2.1/TTF1. Objectives: Our objective was to determine whether pulmonary abnormalities persist in adults with NEHI, to aid in elucidating the natural history of this disease. Methods: Four adult relatives with heterozygous NKX2.1 mutation and with clinical histories compatible with NEHI enrolled in a prospective study that included questionnaires, pulmonary function tests, and chest computed tomography scans. Measurements and Main Results: Mild radiologic abnormalities including mosaicism were seen in all four cases. Three individuals had obstruction on pulmonary function tests, two had marked air trapping, and three had symptomatic impairments with exercise intolerance. Conclusions: Although clinical improvement occurs over time, NEHI may result in lifelong pulmonary abnormalities in some cases. Further studies are required to better describe the natural history of this disease and would be facilitated by additional delineation of genetic mechanisms to enable improved case identification. PMID:27187870
Wink, Jeroen; de Wilde, Rob B P; Wouters, Patrick F; van Dorp, Eveline L A; Veering, Bernadette Th; Versteegh, Michel I M; Aarts, Leon P H J; Steendijk, Paul
2016-10-18
Blockade of cardiac sympathetic fibers by thoracic epidural anesthesia may affect right ventricular function and interfere with the coupling between right ventricular function and right ventricular afterload. Our main objectives were to study the effects of thoracic epidural anesthesia on right ventricular function and ventricular-pulmonary coupling. In 10 patients scheduled for lung resection, right ventricular function and its response to increased afterload, induced by temporary, unilateral clamping of the pulmonary artery, was tested before and after induction of thoracic epidural anesthesia using combined pressure-conductance catheters. Thoracic epidural anesthesia resulted in a significant decrease in right ventricular contractility (ΔESV 25 : +25.5 mL, P=0.0003; ΔEes: -0.025 mm Hg/mL, P=0.04). Stroke work, dP/dt MAX , and ejection fraction showed a similar decrease in systolic function (all P<0.05). A concomitant decrease in effective arterial elastance (ΔEa: -0.094 mm Hg/mL, P=0.004) yielded unchanged ventricular-pulmonary coupling. Cardiac output, systemic vascular resistance, and mean arterial blood pressure were unchanged. Clamping of the pulmonary artery significantly increased afterload (ΔEa: +0.226 mm Hg/mL, P<0.001). In response, right ventricular contractility increased (ΔESV 25 : -26.6 mL, P=0.0002; ΔEes: +0.034 mm Hg/mL, P=0.008), but ventricular-pulmonary coupling decreased (Δ(Ees/Ea) = -0.153, P<0.0001). None of the measured indices showed significant interactive effects, indicating that the effects of increased afterload were the same before and after thoracic epidural anesthesia. Thoracic epidural anesthesia impairs right ventricular contractility but does not inhibit the native positive inotropic response of the right ventricle to increased afterload. Right ventricular-pulmonary arterial coupling was decreased with increased afterload but not affected by the induction of thoracic epidural anesthesia. URL: http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=2844. Unique identifier: NTR2844. © 2016 American Heart Association, Inc.
Seccombe, J; Mirza, F; Hachem, R; Gyawali, C P
2013-08-01
Advanced pulmonary disorders are linked to esophageal hypomotility and reflux disease. However, characterization of esophageal function using high resolution manometry (HRM) and ambulatory pH monitoring, segregation by pulmonary pathology, and comparison to traditional reflux disease are all limited in the literature. Over a 4 year period, 73 patients (55.2 ± 1.3 years, 44F) were identified who underwent esophageal function testing as part of lung transplant evaluation for advanced pulmonary disease (interstitial lung disease, ILD = 47, obstructive lung disease, OLD = 24, other = 2). Proportions of patients with motor dysfunction (≥ 80% failed sequences = severe hypomotility) and/or abnormal reflux parameters (acid exposure time, AET ≥ 4%) were determined, and compared to a cohort of 1081 patients (48.4 ± 0.4 years, 613F) referred for esophageal function testing prior to antireflux surgery (ARS). The proportion of esophageal body hypomotility was significantly higher within advanced pulmonary disease categories (35.6%), particularly ILD (44.7%), compared to ARS patients (12.1%, P < 0.0001). Abnormal AET was noted in 56.5%, and was similar between ILD and OLD, but less frequent than in the ARS group (P = 0.04). Post-transplant chronic rejection trended towards association with pretransplant elevated AET in OLD (P = 0.08) but not ILD. Mortality was not predicted by esophageal motor pattern or reflux evidence. Interstitial lung disease has a highly significant association with esophageal body hypomotility. Consequently, prevalence of abnormal esophageal acid exposure is high, but implications for post lung transplant chronic rejection remain unclear. © 2013 John Wiley & Sons Ltd.
Automated pulmonary lobar ventilation measurements using volume-matched thoracic CT and MRI
NASA Astrophysics Data System (ADS)
Guo, F.; Svenningsen, S.; Bluemke, E.; Rajchl, M.; Yuan, J.; Fenster, A.; Parraga, G.
2015-03-01
Objectives: To develop and evaluate an automated registration and segmentation pipeline for regional lobar pulmonary structure-function measurements, using volume-matched thoracic CT and MRI in order to guide therapy. Methods: Ten subjects underwent pulmonary function tests and volume-matched 1H and 3He MRI and thoracic CT during a single 2-hr visit. CT was registered to 1H MRI using an affine method that incorporated block-matching and this was followed by a deformable step using free-form deformation. The resultant deformation field was used to deform the associated CT lobe mask that was generated using commercial software. 3He-1H image registration used the same two-step registration method and 3He ventilation was segmented using hierarchical k-means clustering. Whole lung and lobar 3He ventilation and ventilation defect percent (VDP) were generated by mapping ventilation defects to CT-defined whole lung and lobe volumes. Target CT-3He registration accuracy was evaluated using region- , surface distance- and volume-based metrics. Automated whole lung and lobar VDP was compared with semi-automated and manual results using paired t-tests. Results: The proposed pipeline yielded regional spatial agreement of 88.0+/-0.9% and surface distance error of 3.9+/-0.5 mm. Automated and manual whole lung and lobar ventilation and VDP were not significantly different and they were significantly correlated (r = 0.77, p < 0.0001). Conclusion: The proposed automated pipeline can be used to generate regional pulmonary structural-functional maps with high accuracy and robustness, providing an important tool for image-guided pulmonary interventions.
De Meester, Pieter; Van De Bruaene, Alexander; Herijgers, Paul; Voigt, Jens-Uwe; Vanhees, Luc; Budts, Werner
2013-08-01
Although closure of an atrial septal defect type secundum often normalizes right heart dimensions and pressures, mild tricuspid insufficiency might persist. This study aimed at (1) identification of determinants explaining the persistence of tricuspid insufficiency after atrial septal defect closure, and (2) evaluation of functional capacity of patients with persistent mild tricuspid insufficiency. Twenty-five consecutive patients (age 42+17 y) were included from the outpatient clinic of congenital heart disease at the University Hospitals of Leuven. All underwent transthoracic echocardiography, semi-supine bicycle stress echocardiography and cardio-pulmonary exercise testing. Six patients (24%) had mild tricuspid insufficiency (2/4) compared to 19 patients (76%) with no or minimal tricuspid insufficiency ( 1/4) as assessed by semi-quantitative colour Doppler echocardiography. Mann-Whitney U and Fisher's exact tests were performed where applicable. Patients with persistent mild tricuspid insufficiency were significantly older than those with no or minimal tricuspid insufficiency (P = 0.042). At rest, no differences in right heart configuration, mean pulmonary artery pressure or right ventricular function were found. At peak exercise, mean pulmonary artery pressure was significantly higher in patients with mild persistent tricuspid insufficiency (P = 0.026). Peak oxygen uptake was significantly lower in patients with mild persistent tricuspid insufficiency (P = 0.019). Mild tricuspid insufficiency after atrial septal defect repair occurs more frequently in older patients and in patients with higher mean pulmonary artery pressure at peak exercise. In patients with mild tricuspid insufficiency, functional capacity was more reduced. Mild tricuspid insufficiency could be a marker of subclinical persistent pressure load on the right ventricle.
Di Marco, Fabiano; Terraneo, Silvia; Job, Sara; Rinaldo, Rocco Francesco; Sferrazza Papa, Giuseppe Francesco; Roggi, Maria Adelaide; Santus, Pierachille; Centanni, Stefano
2017-06-01
The need for additional research on symptomatic smokers with normal spirometry has been recently emphasized. Albeit not meeting criteria for Chronic obstructive pulmonary disease (COPD) diagnosis, symptomatic smokers may experience activity limitation, evidence of airway disease, and exacerbations. We, therefore, evaluated whether symptomatic smokers with borderline spirometry (post-bronchodilator FEV 1 /FVC ratio between 5th to 20th percentile of predicted values) have pulmonary function abnormalities at rest and ventilatory constraints during exercise. 48 subjects (aged 60 ± 8 years, mean ± SD, 73% males, 16 healthy, and 17 symptomatic smokers) underwent cardiopulmonary exercise testing (CPET), body plethysmography, nitrogen single-breath washout test (N 2 SBW), lung diffusion for carbon monoxide (DLCO), and forced oscillation technique (FOT). Compared to healthy subjects, symptomatic smokers showed: 1) reduced breathing reserve (36 ± 17 vs. 49 ± 12%, P = 0.050); 2) exercise induced dynamic hyperinflation (-0.20 ± 0.17 vs. -0.03 ± 0.21 L, P = 0.043); 3) higher residual volume (158 ± 22 vs. 112 ± 22%, P < 0.001); 4) phase 3 slope at N 2 SBW (4.7 ± 2.1 vs. 1.4 ± 0.6%, P < 0.001); 5) no significant differences in DLCO and FOT results. In smokers with borderline spirometry, CPET and second-line pulmonary function tests may detect obstructive pattern. These subjects should be referred for second line testing, to obtain a diagnosis, or at least to clarify the mechanisms underlying symptoms. Whether the natural history of these patients is similar to COPD, and they deserve a similar therapeutic approach is worth investigating. Copyright © 2017 Elsevier Ltd. All rights reserved.
Parot, S; Miara, B; Milic-Emili, J; Gautier, H
1982-11-01
The results of lung function tests (total and functional residual capacities, residual volume/total lung capacity ratio, forced expiratory volume in one second) breathing patterns and arterial PO2 and PCO2 were studied in 651 ambulatory male patients with chronic obstructive pulmonary disease, functionally and clinically stable. Function tests were only loosely correlated with gas tensions: abnormalities in mechanics and in gas exchange are not necessarily related. In patients matched for the degree of obstruction, the breathing pattern depended upon both PaO2 and PaCO2. Isolated hypoxemia was accompanied by increased respiratory frequency without any variation in tidal volume: this suggests that the chemoreceptive systems still responded to changes in PaO2. Isolated hypercapnia was accompanied by a decrease in tidal volume and an increase in respiratory frequency. Consequently, the dead space/tidal volume ratio increased, leading to a drop in alveolar ventilation and to CO2 retention.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramanna, L.; Tashkin, D.P.; Taplin, G.V.
1975-11-01
Seventy subjects with either no, mild, or definite evidence of pulmonary abnormality on screening studies volunteered to have detailed pulmonary function tests (PFTs), respiratory questionnaires, physical examinations, and /sup 113m/indium aerosol-inhalation lung imaging performed. Also, 22 and 52 of these subjects underwent /sup 133/xenon ventilation and lung perfusion imaging with /sup 99m/technetium-labelled macroaggregated albumin, and 56 had chest x-ray examinations performed. Results of the radionuclide lung-imaging procedures were compared with those of conventional PFTs and other clinical diagnostic procedures used to identify chronic obstructive pulmonary disease (COPD). Abnormal radioaerosol patterns were found in 32 of 33 subjects with abnormal findingsmore » on PFTs, whereas results of PFTs were abnormal in only 32 of 46 subjects with abnormal aerosol deposition. Aerosol lung images were abnormal more frequently than respiratory questionnaire responses, findings on physical examination, chest x-ray films, and perfusion lung images and with approximately the same frequency as /sup 133/xenon ventilation scintiscans. These results suggest that radioaerosol lung imaging may be a more sensitive indicator of early COPD than other diagnostic procedures, including maximal midexpiratory flow rates, single-breath nitrogen washout, and closing volume. Further studies are required to determine the physiologic and pathologic significance of isolated aerosol lung-imaging abnormalities.« less
Shen, Cheng-Cheng; Chen, Bing; Gu, Jian-Teng; Ning, Jiao-Lin; Zeng, Jing; Yi, Bin; Lu, Kai-Zhi
2018-03-01
Recent studies have shown that pulmonary angiogenesis is an important pathological process in the development of hepatopulmonary syndrome (HPS), and growing evidence has indicated that Stromal cell-derived factor 1/C-X-C chemokine receptor type 4 (SDF-1/CXCR4) axis is involved in pulmonary vascular disease by mediating the accumulation of c-kit+ cells. This study aimed to test the effect of AMD3100, an antagonist of CXCR4, in HPS pulmonary angiogenesis. Common bile duct ligation (CBDL) rats were used as experimental HPS model and were treated with AMD3100 (1.25mg/kg/day, i.p.) or 0.9% saline for 3weeks. The sham rats underwent common bile duct exposure without ligation. The c-kit+ cells accounts and its angiogenic-related functions, prosurvival signals, pulmonary angiogenesis and arterial oxygenation were analysed in these groups. Our results showed that pulmonary SDF-1/CXCR4, Akt, Erk and VEGF/VEGFR2 were significantly activated in CBDL rats, and the numbers of circulating and pulmonary c-kit+ cells were increased in CBDL rats compared with control rats. Additionally, the angiogenic-related functions of c-kit+ cells and pulmonary microvessel counts were also elevated in CBDL rats. CXCR4 inhibition reduced pulmonary c-kit+ cells and microvessel counts and improved arterial oxygenation within 3weeks in CBDL rats. The pulmonary prosurvival signals and pro-angiogenic activity of c-kit+ cells were also down-regulated in AMD3100-treated rats. In conclusion, AMD3100 treatment attenuated pulmonary angiogenesis in CBDL rats and prevented the development of HPS via reductions in pulmonary c-kit+ cells and inhibition of the prosurvival signals. Our study provides new insights in HPS treatment. Copyright © 2017. Published by Elsevier B.V.
Swift, Andrew J; Rajaram, Smitha; Condliffe, Robin; Capener, Dave; Hurdman, Judith; Elliot, Charlie; Kiely, David G; Wild, Jim M
2012-10-01
The aim of this study was to evaluate the clinical use of magnetic resonance imaging measurements related to pulmonary artery stiffness in the evaluation of pulmonary hypertension (PH). A total of 134 patients with suspected PH underwent right heart catheterization (RHC) and magnetic resonance imaging on a 1.5-T scanner within 2 days. Phase contrast imaging at the pulmonary artery trunk and cine cardiac views were acquired. Pulmonary artery area change (AC), relative AC (RAC), compliance (AC/pulse pressure from RHC), distensibility (RAC/pulse pressure from RHC), right ventricular functional indices, and right ventricular mass were all derived. Regression curve fitting identified the statistical model of best fit between RHC measurements and pulmonary artery stiffness indices. The diagnostic accuracy and prognostic value of noninvasive AC and RAC were also assessed. The relationship between pulmonary vascular resistance and pulmonary artery RAC was best reflected by an inverse linear model. Patients with mild elevation in pulmonary vascular resistance (<4 Woods units) demonstrated reduced RAC (P = 0.02) and increased right ventricular mass index (P < 0.0001) without significant loss of right ventricular function (P = 0.17). At follow-up of 0 to 40 months, 18 patients with PH had died (16%). Analysis of Kaplan-Meier plots showed that both AC and RAC predicted mortality (log-rank test, P = 0.046 and P = 0.012, respectively). Area change and RAC were also predictors of mortality using univariate Cox proportional hazards regression analysis (P = 0.046 and P = 0.03, respectively). Noninvasive assessment of pulmonary artery RAC is a marker sensitive to early increased vascular resistance in PH and is a predictor of adverse outcome.
Improved diagnosis of pulmonary emphysema using in vivo dark-field radiography.
Meinel, Felix G; Yaroshenko, Andre; Hellbach, Katharina; Bech, Martin; Müller, Mark; Velroyen, Astrid; Bamberg, Fabian; Eickelberg, Oliver; Nikolaou, Konstantin; Reiser, Maximilian F; Pfeiffer, Franz; Yildirim, Ali Ö
2014-10-01
The purpose of this study was to assess whether the recently developed method of grating-based x-ray dark-field radiography can improve the diagnosis of pulmonary emphysema in vivo. Pulmonary emphysema was induced in female C57BL/6N mice using endotracheal instillation of porcine pancreatic elastase and confirmed by in vivo pulmonary function tests, histopathology, and quantitative morphometry. The mice were anesthetized but breathing freely during imaging. Experiments were performed using a prototype small-animal x-ray dark-field scanner that was operated at 35 kilovolt (peak) with an exposure time of 5 seconds for each of the 10 grating steps. Images were compared visually. For quantitative comparison of signal characteristics, regions of interest were placed in the upper, middle, and lower zones of each lung. Receiver-operating-characteristic statistics were performed to compare the effectiveness of transmission and dark-field signal intensities and the combined parameter "normalized scatter" to differentiate between healthy and emphysematous lungs. A clear visual difference between healthy and emphysematous mice was found for the dark-field images. Quantitative measurements of x-ray dark-field signal and normalized scatter were significantly different between the mice with pulmonary emphysema and the control mice and showed good agreement with pulmonary function tests and quantitative histology. The normalized scatter showed a significantly higher discriminatory power (area under the receiver-operating-characteristic curve [AUC], 0.99) than dark-field (AUC, 0.90; P = 0.01) or transmission signal (AUC, 0.69; P < 0.001) alone did, allowing for an excellent discrimination of healthy and emphysematous lung regions. In a murine model, x-ray dark-field radiography is technically feasible in vivo and represents a substantial improvement over conventional transmission-based x-ray imaging for the diagnosis of pulmonary emphysema.
Hypothalamic digoxin, hemispheric chemical dominance, and interstitial lung disease.
Kurup, Ravi Kumar; Kurup, Parameswara Achutha
2003-10-01
The isoprenoid pathway produces three key metabolites--endogenous digoxin, dolichol, and ubiquinone. This was assessed in patients with idiopathic pulmonary fibrosis and in individuals of differing hemispheric dominance to find out the role of hemispheric dominance in the pathogenesis of idiopathic pulmonary fibrosis. All 15 cases of interstitial lung disease were right-handed/left hemispheric dominant by the dichotic listening test. The isoprenoidal metabolites--digoxin, dolichol, and ubiquinone, RBC membrane Na(+)-K+ ATPase activity, serum magnesium, tyrosine/tryptophan catabolic patterns, free radical metabolism, glycoconjugate metabolism, and RBC membrane composition--were assessed in idiopathic pulmonary fibrosis as well as in individuals with differing hemispheric dominance. In patients with idiopathic pulmonary fibrosis there was elevated digoxin synthesis, increased dolichol and glycoconjugate levels, and low ubiquinone and elevated free radical levels. There was also an increase in tryptophan catabolites and a reduction in tyrosine catabolites. There was an increase in cholesterol phospholipid ratio and a reduction in glycoconjugate level of RBC membrane in patients with idiopathic pulmonary fibrosis. Isoprenoid pathway dysfunction con tributes to the pathogenesis of idiopathic pulmonary fibrosis. The biochemical patterns obtained in interstitial lung disease are similar to those obtained in left-handed/right hemispheric chemically dominant individuals by the dichotic listening test. However, all the patients with interstitial lung disease were right-handed/left hemispheric dominant by the dichotic listening test. Hemispheric chemical dominance has no correlation with handedness or the dichotic listening test. Interstitial lung disease occurs in right hemispheric chemically dominant individuals and is a reflection of altered brain function.
Legalizing Cannabis: A physician's primer on the pulmonary effects of marijuana.
Lutchmansingh, Denyse; Pawar, Leena; Savici, Dana
2014-01-01
Habitual smoking of marijuana is associated with multiple respiratory symptoms such as cough, sputum production, and wheezing .These symptoms are not significantly different from those exhibited by tobacco smokers. Furthermore, endobronchial biopsies of habitual smokers of marijuana and /or tobacco have shown that both marijuana and cigarette smoking cause significant bronchial mucosal histopathology and that these effects are additive. Although marijuana smokers have minimal changes in pulmonary function studies as compared to tobacco smokers, they may develop bullous disease and spontaneous pneumothoraces. The relationship between marijuana smoking and lung cancer remains unclear due to design limitations of the studies published so far. These findings should warn individuals that marijuana smoking may result in serious short-term and long-term respiratory complications, and habitual marijuana use should be viewed with caution. The medical literature so far does not support routine evaluation by pulmonary function tests or imaging studies; until more definitive data is available, we do not recommend the regular use of these tests in the evaluation of habitual marijuana smokers.
McLaughlin, Vallerie V; Langer, Anatoly; Tan, Mary; Clements, Philip J; Oudiz, Ronald J; Tapson, Victor F; Channick, Richard N; Rubin, Lewis J
2013-02-01
The Pulmonary Arterial Hypertension-Quality Enhancement Research Initiative (PAHQuERI) was created to help clinicians to implement a guidelines-based approach to the diagnosis and management of pulmonary arterial hypertension (PAH). Patients with PAH represent a heterogeneous population, and physician evaluation and treatment paradigms may vary considerably. Using an electronic data management system, participating physicians recorded data on diagnostic workup, disease management, and outcomes of patients with PAH. Queries were generated automatically following each follow-up visit if the tests recommended by the American College of Chest Physicians (ACCP) were not performed at least once. Of 791 patients enrolled in PAH-QuERI, 77% were women; 64% received a diagnosis . 3 months prior to enrollment; 9% were in New York Heart Association functional class I, 39% in II, 48% in III, and 5% in IV; and the median age was 55 years (interquartile range, 45-66 years). At enrollment, all ACCP-recommended tests had been performed in only 6% of patients. The automated program generated 1,530 reminders for 642 patients (81%) with validated enrollment data. The proportion of recommended tests performed was 91% for CBC count, 91% for liver function test, 50% for connective tissue disease screen, 29% for HIV screen, 88% for chest radiograph, 82% for ECG, 97% for two-dimensional echocardiogram, 83% for pulmonary function tests, 41% for oximetry, 57% for ventilation/perfusion scan, 79% for 6-min walk distance, and 90% for right-sided heart catheterization. Regarding management, 78% of patients were on disease specific therapy, and the use of these therapies tended to increase with the functional disability of the patient. One hundred seventy patients were taking calcium channel blockers, 91 specifically for PAH. Only six of 91 patients (7%) who received calcium channel blockers specifically for PAH had met the current guideline for acute vasoreactivity. When comparing reported clinical practice with ACCP guidelines-recommended strategies, a diagnostic care gap is apparent such that certain essential and recommended diagnostic tests may be underused despite the availability of detailed guidelines and reminders.
The influence of kyphosis correction surgery on pulmonary function and thoracic volume.
Zeng, Yan; Chen, Zhongqiang; Ma, Desi; Guo, Zhaoqing; Qi, Qiang; Li, Weishi; Sun, Chuiguo; Liu, Ning; White, Andrew P
2014-10-01
A clinical study. To measure the changes in pulmonary function and thoracic volume associated with surgical correction of kyphotic deformities. No prior study has focused on the pulmonary function and thoracic cavity volume before and after corrective surgery for kyphosis. Thirty-four patients with kyphosis underwent posterior deformity correction with instrumented fusion. Preoperative and postoperative pulmonary function was measured, and pulmonary function grade was evaluated as mild, significant, or severe. The change in preoperative to postoperative pulmonary function was analyzed, using 6 comparative subgroupings of patients on the basis of age, severity of kyphosis, location of kyphosis apex, length of follow-up time after surgery, degree of kyphosis correction, and number of segments fused. A second group of 19 patients also underwent posterior surgical correction of kyphosis, which had thoracic volume measured preoperatively and postoperatively with computed tomographic scanning. All of the pulmonary impairments were found to be restrictive. After surgery, most of the patients had improvement of the pulmonary function. Before surgery, the pulmonary function differences were found to be significant based on both severity of preoperative kyphosis (<60° vs. >60°) and location of the kyphosis apex (above T10 vs. below T10). Younger patients (younger than 35 yr) were more likely to exhibit statistically significant improvements in pulmonary function after surgery. However, thoracic volume was not significantly related to pulmonary function parameters. After surgery, average thoracic volume had no significant change. The major pulmonary impairment caused by kyphosis was found to be restrictive. Patients with kyphosis angle of 60° or greater or with kyphosis apex above T10 had more severe pulmonary dysfunction. Patients' age was significantly related to change in pulmonary function after surgery. However, the average thoracic volume had no significant change after surgery. 3.
Pulmonary function in obese vs non-obese cats.
García-Guasch, Laín; Caro-Vadillo, Alicia; Manubens-Grau, Jordi; Carretón, Elena; Camacho, Aparecido A; Montoya-Alonso, José Alberto
2015-06-01
Obesity is a risk factor in the development of several respiratory diseases. Lung volumes tend to be decreased, especially expiratory reserve volume, increasing expiratory flow limitation during tidal breathing. Barometric whole-body plethysmography is a non-invasive pulmonary function test that allows a dynamic study of breathing patterns. The objective of this study was to compare pulmonary function variables between obese and non-obese cats through the use of barometric whole-body plethysmography. Nine normal-weight and six obese cats were placed in the plethysmograph chamber, and different respiratory variables were measured. There was a significant decrease in tidal volume per kilogram (P = 0.003), minute volume per kilogram (P = 0.001) and peak inspiratory and expiratory flows per kilogram (P = 0.001) in obese cats compared with non-obese cats. Obesity failed to demonstrate a significant increase in bronchoconstriction index variable enhanced pause (Penh), as previously reported in humans and dogs. The results show that feline obesity impairs pulmonary function in cats, although a significant increase in bronchoconstriction indexes was not observed. Non-invasive barometric whole-body plethysmography can help characterise mechanical dysfunction of the airways in obese cats. © ISFM and AAFP 2014.
Breathing pattern and breathlessness in idiopathic pulmonary fibrosis: An observational study.
Olukogbon, Kasope L; Thomas, Paul; Colasanti, Ricardo; Hope-Gill, Ben; Williams, Edgar Mark
2016-02-01
Idiopathic pulmonary fibrosis (IPF) is characterized by progressive decline in lung function and increasing dyspnoea. The aim of this study was to investigate the relationship among IPF, pulmonary function, resting tidal breathing patterns and level of breathlessness. Thirty-one participants with IPF and 17 matched healthy controls underwent lung function testing, followed by a 2-min period of resting tidal breathing. The IPF cohort was stratified according to disease severity, based on their forced vital capacity and diffusion capacity for carbon monoxide. In comparison to the healthy controls, the IPF cohort showed a higher tidal volume, VT , of 0.22 L (P = 0.026) and a raised minute ventilation in the severest IPF group, while no differences in the timing of inspiration or expiration were observed. In the IPF cohort, the ratio of VT to forced vital capacity was around 15% higher. These changes corresponded with an increase in the self-reported sensation of breathlessness. Those with IPF increased their depth of breathing with worsening disease severity, with IPF-induced changes in pulmonary function and breathlessness associated with an altered tidal breathing pattern. © 2015 Asian Pacific Society of Respirology.
Exposure to wood smoke particles produces inflammation in healthy volunteers.
Ghio, Andrew J; Soukup, Joleen M; Case, Martin; Dailey, Lisa A; Richards, Judy; Berntsen, Jon; Devlin, Robert B; Stone, Susan; Rappold, Ana
2012-03-01
Human exposure to wood smoke particles (WSP) impacts on human health through changes in indoor air quality, exposures from wild fires, burning of biomass and air pollution. This investigation tested the postulate that healthy volunteers exposed to WSP would demonstrate evidence of both pulmonary and systemic inflammation. Ten volunteers were exposed to filtered air and, 3 weeks or more later, WSP. Each exposure included alternating 15 min of exercise and 15 min of rest for a total duration of 2 h. Wood smoke was generated by heating an oak log on an electric element and then delivered to the exposure chamber. Endpoints measured in the volunteers included symptoms, pulmonary function tests, measures of heart rate variability and repolarisation, blood indices and analysis of cells and fluid obtained during bronchoalveolar lavage. Mean particle mass for the 10 exposures to air and WSP was measured using the mass of particles collected on filters and found to be below the detectable limit and 485±84 μg/m(3), respectively (mean±SD). There was no change in either symptom prevalence or pulmonary function with exposure to WSP. At 20 h after wood smoke exposure, blood tests demonstrated an increased percentage of neutrophils, and bronchial and bronchoalveolar lavage revealed a neutrophilic influx. We conclude that exposure of healthy volunteers to WSP may be associated with evidence of both systemic and pulmonary inflammation.
Abdelbasset, Walid K; Alsubaie, Saud F; Tantawy, Sayed A; Abo Elyazed, Tamer I; Kamel, Dalia M
2018-01-01
It has been documented that aerobic exercise may increase pulmonary functions and aerobic capacity, but limited data has evaluated a child's satisfaction and pediatric quality of life (PQoL) with exercise training. This study aimed to investigate the effects of moderate-intensity exercise training on asthmatic school-aged children. This study included 38 school-aged children with asthma (23 males and 15 females) aged between 8-12 years. They were randomly assigned to two groups, aerobic exercise (AE) and conventional treatment (Con ttt) groups. The AE group received a program of moderate-intensity aerobic exercise for 10 weeks with asthma medications and the Con ttt group received only asthma medications without exercise intervention. A home respiratory exercise was recommended for the two groups. Aerobic capacity was investigated using maximal oxygen uptake (VO 2max ), 6-minute walk test (6MWT), and fatigue index. PQoL was evaluated using Pediatric Quality of Life Questionnaire (PQoLQ). Also, pulmonary function tests were performed, and the results recorded. The findings of this study showed significant improvements in pulmonary functions and VO 2max in the two groups; however, this improvement was significantly higher in the AE group than in the Con ttt group ( p <0.05). The 6MWT and fatigue index improved in the AE group ( p <0.05) but not in the Con ttt group ( p >0.05). All dimensions of PQoL significantly improved in the AE group ( p <0.05), but there was no significant improvement in the Con ttt group after the 10-week intervention period ( p >0.05). Ten weeks of physical exercise had beneficial effects on pulmonary functions, aerobic capacity, and PQoL in school-aged children with asthma. Effort and awareness should be dedicated to encouraging the active lifestyle among different populations, especially asthmatic children.
Effects of biomass smoke on pulmonary functions: a case control study.
Balcan, Baran; Akan, Selcuk; Ugurlu, Aylin Ozsancak; Handemir, Bahar Ozcelik; Ceyhan, Berrin Bagcı; Ozkaya, Sevket
2016-01-01
Biomass smoke is the leading cause of COPD in developing countries such as Turkey. In rural areas of Turkey, females are more exposed to biomass smoke because of traditional lifestyles. The aim of this study was to determine the adverse effects of biomass smoke on pulmonary functions and define the relationship between duration in years and an index (cumulative exposure index) with altered pulmonary function test results. A total of 115 females who lived in the village of Kağizman (a borough of Kars located in the eastern part of Turkey) and were exposed to biomass smoke were included in the study. The control group was generated with 73 individuals living in the same area who were never exposed to biomass smoke. Twenty-seven (23.8%) females in the study group and four (5.5%) in the control group had small airway disease (P=0.038). Twenty-two (19.1%) females in the study group and ten (13.7%) in the control group had obstruction (P=0.223). Twenty (17.3%) females in the study group who were exposed to biomass smoke had restriction compared with ten (13%) in the control group (P=0.189). The duration needed for the existence of small airway disease was 16 years, for obstructive airway disease was 17 years, and for restrictive airway disease was 17 years. The intensity of biomass smoke was defined in terms of cumulative exposure index; it was calculated by multiplying hours per day, weeks per month, and total years of smoke exposure and dividing the result by three. Exposure to biomass smoke is a serious public health problem, especially in rural areas of developing countries, because of its negative effects on pulmonary functions. As the duration and the intensity of exposure increase, the probability of having altered pulmonary function test results is higher.
Abnormal pulmonary function in adults with sickle cell anemia.
Klings, Elizabeth S; Wyszynski, Diego F; Nolan, Vikki G; Steinberg, Martin H
2006-06-01
Pulmonary complications of sickle cell anemia (Hb-SS) commonly cause morbidity, yet few large studies of pulmonary function tests (PFTs) in this population have been reported. PFTs (spirometry, lung volumes, and diffusion capacity for carbon monoxide [DLCO]) from 310 adults with Hb-SS were analyzed to determine the pattern of pulmonary dysfunction and their association with other systemic complications of sickle cell disease. Raw PFT data were compared with predicted values. Each subject was subclassified into one of five groups: obstructive physiology, restrictive physiology, mixed obstructive/restrictive physiology, isolated low DLCO, or normal. The association between laboratory data of patients with decreased DLCO or restrictive physiology and those of normal subjects was assessed by multivariate linear regression. Normal PFTs were present in only 31 of 310 (10%) patients. Overall, adults with Hb-SS were characterized by decreased total lung capacities (70.2 +/- 14.7% predicted) and DLCO (64.5 +/- 19.9%). The most common PFT patterns were restrictive physiology (74%) and isolated low DLCO (13%). Decreased DLCO was associated with thrombocytosis (p = 0.05), with hepatic dysfunction (elevated alanine aminotransferase; p = 0.07), and a trend toward renal dysfunction (elevated blood urea nitrogen and creatinine; p = 0.05 and 0.07, respectively). Pulmonary function is abnormal in 90% of adult patients with Hb-SS. Common abnormalities include restrictive physiology and decreased DLCO. Decreased DLCO may indicate more severe sickle vasculopathy characterized by impaired hepatic and renal function.
Potential Role of Lung Ventilation Scintigraphy in the Assessment of COPD
Cukic, Vesna; Begic, Amela
2014-01-01
Objective: To highlight the importance of the lung ventilation scintigraphy (LVS) to study the regional distribution of lung ventilation and to describe most frequent abnormal patterns of lung ventilation distribution obtained by this technique in COPD and to compare the information obtained by LVS with the that obtained by traditional lung function tests. Material and methods: The research was done in 20 patients with previously diagnosed COPD who were treated in Intensive care unit of Clinic for pulmonary diseases and TB “Podhrastovi” Clinical Center, University of Sarajevo in exacerbation of COPD during first three months of 2014. Each patient was undergone to testing of pulmonary function by body plethysmography and ventilation/perfusion lung scintigraphy with radio pharmaceutics Technegas, 111 MBq Tc -99m-MAA. We compared the results obtained by these two methods. Results: All patients with COPD have a damaged lung function tests examined by body plethysmography implying airflow obstruction, but LVS indicates not only airflow obstruction and reduced ventilation, but also indicates the disorders in distribution in lung ventilation. Conclusion: LVS may add further information to the functional evaluation of COPD to that provided by traditional lung function tests and may contribute to characterizing the different phenotypes of COPD. PMID:25132709
Clinical characterization of children with resistant airflow obstruction, a multicenter study.
Krishnan, Sankaran; Dozor, Allen J; Bacharier, Leonard; Lang, Jason E; Irvin, Charles G; Kaminsky, David; Farber, Harold J; Gerald, Lynn; Brown, Mark; Holbrook, Janet T; Wise, Robert A; Ryu, Julie; Bose, Sonali; Yasin, Razan; Saams, Joy; Henderson, Robert J; Teague, William G
2018-05-17
To characterize a cohort of children with airflow limitation resistant to bronchodilator (BD) therapy. Pulmonary function tests performed in children 6-17 years of age at 15 centers in a clinical research consortium were screened for resistant airflow limitation, defined as a post-BD FEV 1 and/or an FEV 1 /FVC less than the lower limits of normal. Demographic and clinical data were analyzed for associations with pulmonary function. 582 children were identified. Median age was 13 years (IQR: 11, 16), 60% were males; 62% were Caucasian, 28% were African-American; 19% were obese; 32% were born prematurely and 21% exposed to second hand smoke. Pulmonary diagnoses included asthma (93%), prior significant pneumonia (28%), and bronchiectasis (5%). 65% reported allergic rhinitis, and 11% chronic sinusitis. Subjects without a history of asthma had significantly lower post-BD FEV 1 % predicted (p = 0.008). Subjects without allergic rhinitis had lower post-BD FEV 1 % predicted (p = 0.003). Children with allergic rhinitis, male sex, obesity and Black race had better pulmonary function post-BD. There was lower pulmonary function in children after age 11 years without a history of allergic rhinitis, as compared to those with a history of allergic rhinitis. The most prevalent diagnosis in children with BD-resistant airflow limitation is asthma. Allergic rhinitis and premature birth are common co-morbidities. Children without a history of asthma, as well as those with asthma but no allergic rhinitis, had lower pulmonary function. Children with BD-resistant airflow limitation may represent a sub-group of children with persistent obstruction and high risk for life-long airway disease.
de Mendonça Cardoso, Marcio; Gepp, Ricardo; Correa, José Fernando Guedes
2016-09-01
The phrenic nerve can be transferred to the musculocutaneous nerve in patients with traumatic brachial plexus palsy in order to recover biceps strength, but the results are controversial. There is also a concern about pulmonary function after phrenic nerve transection. In this paper, we performed a qualitative systematic review, evaluating outcomes after this procedure. A systematic review of published studies was undertaken in accordance with the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) statement. Data were extracted from the selected papers and related to: publication, study design, outcome (biceps strength in accordance with BMRC and pulmonary function) and population. Study quality was assessed using the "strengthening the reporting of observational studies in epidemiology" (STROBE) standard or the CONSORT checklist, depending on the study design. Seven studies were selected for this systematic review after applying inclusion and exclusion criteria. One hundred twenty-four patients completed follow-up, and most of them were graded M3 or M4 (70.1 %) for biceps strength at the final evaluation. Pulmonary function was analyzed in five studies. It was not possible to perform a statistical comparison between studies because the authors used different parameters for evaluation. Most of the patients exhibited a decrease in pulmonary function tests immediately after surgery, with recovery in the following months. Study quality was determined using STROBE in six articles, and the global score varied from 8 to 21. Phrenic nerve transfer to the musculocutaneous nerve can recover biceps strength ≥M3 (BMRC) in most patients with traumatic brachial plexus injury. Early postoperative findings revealed that the development of pulmonary symptoms is rare, but it cannot be concluded that the procedure is safe because there is no study evaluating pulmonary function in old age.
Astronaut William McArthur in medical experiment in SLS-2
NASA Technical Reports Server (NTRS)
1993-01-01
Astronaut William S. McArthur, mission specialist, participates in an experiment using the rebreathing assembly and a gas analyzer mass spectrometer that investigates in-space distribution and movement of blood and gas in the pulmonary system. The data gathered during the two-week flight will be compared with results of tests performed on Earth to determine the changes that occur in pulmonary functions.
Astronaut David Wolf in medical experiment in SLS-2
1993-10-28
STS058-204-014 (18 Oct.-1 Nov. 1993) --- Astronaut David A. Wolf, mission specialist, participates in an experiment that investigates in-space distribution and movement of blood and gas in the pulmonary system. The data gathered during the two-week flight will be compared with results of tests performed on Earth to determine the changes that occur in pulmonary functions. Photo credit: NASA
Strevens Bolmgren, Victor; Olsson, Peter; Wollmer, Per; Hesselstrand, Roger; Mandl, Thomas
2017-05-01
Involvement of the respiratory system, in particular dry airways and chronic obstructive pulmonary disease (COPD), is common in patients with primary Sjögren's syndrome (pSS). As respiratory symptoms are also common in pSS patients and may have different etiologies, we wanted to evaluate the amount and impact of respiratory symptoms in out-patients with pSS and to assess if such symptoms are related to concomitant COPD. The St George's Respiratory Questionnaire (SGRQ) was used to assess respiratory symptoms. SGRQ scores were compared between 51 consecutive pSS patients, in an out-patient setting, and 80 population-based controls. The patients were also studied by pulmonary function tests and CT scans of the lungs to assess signs of obstructive airway disease, including COPD, as well as to assess signs of interstitial lung disease (ILD). 41 and 18% of pSS patients were found to have COPD and radiographic signs of ILD, respectively. pSS patients had significantly higher SGRQ scores compared to controls, but no significant differences in SGRQ scores were found between patients with and without COPD. Neither did the small group of pSS patients with ILD significantly differ in SGRQ scores in comparison to patients without ILD. Respiratory symptoms were common in pSS, but were not more common in patients with concomitant COPD. Since pulmonary involvement in pSS is associated with an increased mortality and respiratory symptoms is a poor marker for pulmonary involvement, we suggest that pulmonary function tests should be performed liberally in all pSS patients regardless of symptoms.
Hammad, A; Osman, E; Mosaad, Y; Wahba, M
2017-04-01
Objective Pulmonary involvement in paediatric systemic lupus erythematosus (pSLE) is not an uncommon finding; however, subclinical affection occurs more frequently. Many studies have reported that cytokine dysregulation as interleukin-17 (IL-17) over-expression plays a key role in the pathogenesis of systemic lupus erythematosus (SLE). We aim to assess serum levels of IL-17 A and their association with pulmonary involvement in children with SLE. Methods Serum IL-17A levels - determined by solid phase sandwich ELISA - were assessed in forty-two pSLE patients and compared to 45 age-matched healthy controls. All patients were subjected to pulmonary function tests to detect subclinical pulmonary affection. High-resolution CT (HRCT) chest scan was carried out in patients with abnormal pulmonary function tests (PFTs) and those with chronic respiratory symptoms. Results Abnormal PFTs were found in 73% of patients; of them, only 25% had abnormal findings in HRCT chest. Serum levels of IL-17 A were significantly elevated in pSLE patients as compared to healthy controls ( p < 0.001). The serum levels of IL-17 A had a highly significant positive correlation with SLEDAI ( r = 0.811 and p < 0.001) Strong negative correlation was found between serum levels of IL-17A with both FEV1 and FVC ( p < 0.05). Conclusions Serum IL-17A is elevated in pSLE patients, which correlates with disease activity. IL-17 seems to have a possible role in the pathogenesis of subclinical lung affection. Abnormal PFTS may be found in pSLE patients even with normal radiology.
Pulmonary changes in liver transplant candidates with hepatitis C cirrhosis.
Al-Moamary, M S; Gorka, T; Al-Traif, I H; Al-Jahdali, H H; Al-Shimemeri, A A; Al-Kanway, B; Abdulkareeem, A A; Abdulkareeem, A A
2001-12-01
Several studies have shown that pulmonary abnormalities are common in patients with end-stage liver disease. However, most of these studies were conducted on patients with heterogeneous etiologies. Therefore, we studied these changes in a homogenous group of hepatitis C cirrhotic patients who were potential candidates for liver transplantation. The charts of 81 patients from King Fahad National Guard Hospital, Riyadh, Kingdom of Saudi Arabia with hepatitis C cirrhosis who were evaluated for liver transplantation were reviewed. The following data was retrieved: echocardiography with micro-bubble study, arterial blood gases, and pulmonary function tests of 81 candidates and reviewed over 3 years from 1994 to 1997. The mean age was 53 (+/-9) years with male to female ratio of 1.4:1. Echocardiographic micro-bubble study, revealed 4 of 62 (7%) had an intrapulmonary shunt. Arterial blood gases results were pH of 7.44 (+/-0.4), partial arterial tension of carbon dioxide of 33 mm Hg (+/-4), partial arterial tension of oxygen of 84 mm Hg (+/-12), and alveolar-arterial gradient of 30 mm Hg (+/-10). Eleven percent had obstructive airway disease, 17% had restrictive lung impairment, and 43% had reduced diffusion capacity. Seventy five percent of patients with reduced diffusion capacity had normal lung volumes. Various pulmonary function test abnormalities did not lead to significant differences in arterial blood gases. Pulmonary changes were frequent in liver transplant candidates with hepatitis C virus cirrhosis with reduced diffusion capacity being the most. Apart from the effect of hepatopulmonary syndrome on arterial oxygenation, other pulmonary abnormalities were not significantly different.
2012-01-01
Background Due partly to physicians’ unawareness, many adults with Pompe disease are diagnosed with great delay. Besides, it is not well known which factors influence the rate of disease progression, and thus disease outcome. We delineated the specific clinical features of Pompe disease in adults, and mapped out the distribution and severity of muscle weakness, and the sequence of involvement of the individual muscle groups. Furthermore, we defined the natural disease course and identified prognostic factors for disease progression. Methods We conducted a single-center, prospective, observational study. Muscle strength (manual muscle testing, and hand-held dynamometry), muscle function (quick motor function test), and pulmonary function (forced vital capacity in sitting and supine positions) were assessed every 3–6 months and analyzed using repeated-measures ANOVA. Results Between October 2004 and August 2009, 94 patients aged between 25 and 75 years were included in the study. Although skeletal muscle weakness was typically distributed in a limb-girdle pattern, many patients had unfamiliar features such as ptosis (23%), bulbar weakness (28%), and scapular winging (33%). During follow-up (average 1.6 years, range 0.5-4.2 years), skeletal muscle strength deteriorated significantly (mean declines of −1.3% point/year for manual muscle testing and of −2.6% points/year for hand-held dynamometry; both p<0.001). Longer disease duration (>15 years) and pulmonary involvement (forced vital capacity in sitting position <80%) at study entry predicted faster decline. On average, forced vital capacity in supine position deteriorated by 1.3% points per year (p=0.02). Decline in pulmonary function was consistent across subgroups. Ten percent of patients declined unexpectedly fast. Conclusions Recognizing patterns of common and less familiar characteristics in adults with Pompe disease facilitates timely diagnosis. Longer disease duration and reduced pulmonary function stand out as predictors of rapid disease progression, and aid in deciding whether to initiate enzyme replacement therapy, or when. PMID:23147228
Kotani, Toshiaki; Akazawa, Tsutomu; Sakuma, Tsuyoshi; Nagaya, Shigeyuki; Sonoda, Masaru; Tanaka, Yuji; Katogi, Takehide; Nemoto, Tetsuharu; Minami, Shohei
2015-06-01
To investigate the effectiveness of incentive spirometry on respiratory motion in healthy subjects using cine breathing magnetic resonance imaging (MRI). Ten non-smoking healthy subjects without any history of respiratory disease were studied. Subjects were asked to perform pulmonary training using incentive spirometry every day for two weeks. To assess the effectiveness of this training, pulmonary function tests and cine breathing MRI were performed before starting pulmonary training and two weeks after its completion. After training, there were significant improvements in vital capacity (VC) from 3.58±0.8 L to 3.74±0.8 L and in %VC from 107.4±10.8 to 112.1±8.2. Significant changes were observed in the right diaphragm motion, right chest wall motion, and left chest wall motion, which were increased from 55.7±9.6 mm to 63.4±10.2 mm, from 15.6±6.1 mm to 23.4±10.4 mm, and from 16.3±7.6 mm to 22.0±9.8 mm, respectively. Two weeks of training using incentive spirometry provided improvements in pulmonary function and respiratory motion, which suggested that incentive spirometry may be a useful preoperative modality for improving pulmonary function during the perioperative period.
A Feline HFpEF Model with Pulmonary Hypertension and Compromised Pulmonary Function.
Wallner, Markus; Eaton, Deborah M; Berretta, Remus M; Borghetti, Giulia; Wu, Jichuan; Baker, Sandy T; Feldsott, Eric A; Sharp, Thomas E; Mohsin, Sadia; Oyama, Mark A; von Lewinski, Dirk; Post, Heiner; Wolfson, Marla R; Houser, Steven R
2017-11-29
Heart Failure with preserved Ejection Fraction (HFpEF) represents a major public health problem. The causative mechanisms are multifactorial and there are no effective treatments for HFpEF, partially attributable to the lack of well-established HFpEF animal models. We established a feline HFpEF model induced by slow-progressive pressure overload. Male domestic short hair cats (n = 20), underwent either sham procedures (n = 8) or aortic constriction (n = 12) with a customized pre-shaped band. Pulmonary function, gas exchange, and invasive hemodynamics were measured at 4-months post-banding. In banded cats, echocardiography at 4-months revealed concentric left ventricular (LV) hypertrophy, left atrial (LA) enlargement and dysfunction, and LV diastolic dysfunction with preserved systolic function, which subsequently led to elevated LV end-diastolic pressures and pulmonary hypertension. Furthermore, LV diastolic dysfunction was associated with increased LV fibrosis, cardiomyocyte hypertrophy, elevated NT-proBNP plasma levels, fluid and protein loss in pulmonary interstitium, impaired lung expansion, and alveolar-capillary membrane thickening. We report for the first time in HFpEF perivascular fluid cuff formation around extra-alveolar vessels with decreased respiratory compliance. Ultimately, these cardiopulmonary abnormalities resulted in impaired oxygenation. Our findings support the idea that this model can be used for testing novel therapeutic strategies to treat the ever growing HFpEF population.
Aweto, Happiness Anulika; Aiyegbusi, Ayoola Ibifubara; Ugonabo, Adaora Justina; Adeyemo, Titilope Adenike
2016-01-01
Pulmonary complications, respiratory symptoms and depression are common occurrences which contribute to the morbidity and mortality seen in individuals living with HIV/AIDS. This study investigated the effect of aerobic exercise on the pulmonary functions, respiratory symptoms and psychological status of people living with HIV. This study was conducted in Lagos, Nigeria from October 2014 to May 2015. Forty eligible individuals with HIV aged 18 yr and above participated, of which 33 cooperated to the end. They were recruited from the HIV/AIDS Prevention and Intervention Initiative (APIN) Clinic, Lagos University Teaching Hospital, Nigeria and were randomly assigned to either the study or the control group. The study group received aerobic exercise training three times a week for six weeks and counselling while the control group received only counselling. Pulmonary functions, respiratory symptoms and psychological status were evaluated at baseline and at six weeks. Inferential statistics of paired and independent t-test were used to analyse the data. Comparison of mean changes in the pulmonary variables of the study group with those of the control group showed significant differences in all but in the respiratory rate (RR) - [Forced Expiratory Volume in one second: P=0.001, Forced Vital Capacity: P=0.001, Peak Expiratory Flow: P=0.001]. There were also significant differences between the mean changes in respiratory symptoms (P=0.001) and depressive symptoms (P=0.001) of study group and those of the control group. Aerobic exercise training significantly improved pulmonary functions as well as significantly reduced respiratory and depressive symptoms in people living with HIV.
Scarneciu, Camelia C; Sangeorzan, Livia; Rus, Horatiu; Scarneciu, Vlad D; Varciu, Mihai S; Andreescu, Oana; Scarneciu, Ioan
2017-01-01
This study aimed at assessing the incidence of pulmonary hypertension (PH) at newly diagnosed hyperthyroid patients and at finding a simple model showing the complex functional relation between pulmonary hypertension in hyperthyroidism and the factors causing it. The 53 hyperthyroid patients (H-group) were evaluated mainly by using an echocardiographical method and compared with 35 euthyroid (E-group) and 25 healthy people (C-group). In order to identify the factors causing pulmonary hypertension the statistical method of comparing the values of arithmetical means is used. The functional relation between the two random variables (PAPs and each of the factors determining it within our research study) can be expressed by linear or non-linear function. By applying the linear regression method described by a first-degree equation the line of regression (linear model) has been determined; by applying the non-linear regression method described by a second degree equation, a parabola-type curve of regression (non-linear or polynomial model) has been determined. We made the comparison and the validation of these two models by calculating the determination coefficient (criterion 1), the comparison of residuals (criterion 2), application of AIC criterion (criterion 3) and use of F-test (criterion 4). From the H-group, 47% have pulmonary hypertension completely reversible when obtaining euthyroidism. The factors causing pulmonary hypertension were identified: previously known- level of free thyroxin, pulmonary vascular resistance, cardiac output; new factors identified in this study- pretreatment period, age, systolic blood pressure. According to the four criteria and to the clinical judgment, we consider that the polynomial model (graphically parabola- type) is better than the linear one. The better model showing the functional relation between the pulmonary hypertension in hyperthyroidism and the factors identified in this study is given by a polynomial equation of second degree where the parabola is its graphical representation.
Boutou, Afroditi K; Nair, Arjun; Douraghi-Zadeh, Dariush; Sandhu, Ranbir; Hansell, David M; Wells, Athol U; Polkey, Michael I; Hopkinson, Nicholas S
2014-01-01
Chronic Obstructive Pulmonary Disease (COPD) is characterized by high morbidity and mortality. Lung computed tomography parameters, individually or as part of a composite index, may provide more prognostic information than pulmonary function tests alone. To investigate the prognostic value of emphysema score and pulmonary artery measurements compared with lung function parameters in COPD and construct a prognostic index using a contingent staging approach. Predictors of mortality were assessed in COPD outpatients whose lung computed tomography, spirometry, lung volumes and gas transfer data were collected prospectively in a clinical database. Univariate and multivariate Cox proportional hazard analysis models with bootstrap techniques were used. 169 patients were included (59.8% male, 61.1 years old; Forced Expiratory Volume in 1 second % predicted: 40.5±19.2). 20.1% died; mean survival was 115.4 months. Age (HR = 1.098, 95% Cl = 1.04-1.252) and emphysema score (HR = 1.034, 95% CI = 1.007-1.07) were the only independent predictors of mortality. Pulmonary artery dimensions were not associated with survival. An emphysema score of 55% was chosen as the optimal threshold and 30% and 65% as suboptimals. Where emphysema score was between 30% and 65% (intermediate risk) the optimal lung volume threshold, a functional residual capacity of 210% predicted, was applied. This contingent staging approach separated patients with an intermediate risk based on emphysema score alone into high risk (Functional Residual Capacity ≥210% predicted) or low risk (Functional Residual Capacity <210% predicted). This approach was more discriminatory for survival (HR = 3.123; 95% CI = 1.094-10.412) than either individual component alone. Although to an extent limited by the small sample size, this preliminary study indicates that the composite Emphysema score-Functional Residual Capacity index might provide a better separation of high and low risk patients with COPD, than other individual predictors alone.
Soysal Tomruk, Melda; Ozalevli, Sevgi; Dizdar, Gorkem; Narin, Selnur; Kilinc, Oguz
2015-07-01
Hand dexterity is important for daily living activities and can be related to cognitive functions in patients with chronic obstructive pulmonary disease (COPD). The aim of this study was to investigate the relationship between cognitive dysfunction and hand dexterity in patients with COPD. 35 COPD patients and 36 healthy individuals were assessed. The Minnesota Hand Dexterity Test and Mini Mental State Examination (MMSE) were used for assessment of cognitive function and hand dexterity. Hand dexterity test scores and cognitive function of COPD patients' were significantly lower than the healthy group (p < 0.01). The MMSE scores were negatively correlated with hand dexterity scores in the COPD group (p < 0.05). There was a relationship between cognitive function and hand dexterity in the patients with COPD; however, hand dexterity did not alter according to hypoxemia severity. Hand dexterity which is important in daily living activities should be evaluated in greater detail with further studies in COPD patients.
Ni, Ke; Liu, Ming; Zheng, Jian; Wen, Liyan; Chen, Qingyun; Xiang, Zheng; Lam, Kowk-Tai; Liu, Yinping; Chan, Godfrey Chi-Fung; Lau, Yu-Lung; Tu, Wenwei
2018-06-01
Pulmonary fibrosis is a chronic progressive lung disease with few treatments. Human mesenchymal stem cells (MSCs) have been shown to be beneficial in pulmonary fibrosis because they have immunomodulatory capacity. However, there is no reliable model to test the therapeutic effect of human MSCs in vivo. To mimic pulmonary fibrosis in humans, we established a novel bleomycin-induced pulmonary fibrosis model in humanized mice. With this model, the benefit of human MSCs in pulmonary fibrosis and the underlying mechanisms were investigated. In addition, the relevant parameters in patients with pulmonary fibrosis were examined. We demonstrate that human CD8 + T cells were critical for the induction of pulmonary fibrosis in humanized mice. Human MSCs could alleviate pulmonary fibrosis and improve lung function by suppressing bleomycin-induced human T-cell infiltration and proinflammatory cytokine production in the lungs of humanized mice. Importantly, alleviation of pulmonary fibrosis by human MSCs was mediated by the PD-1/programmed death-ligand 1 pathway. Moreover, abnormal PD-1 expression was found in circulating T cells and lung tissues of patients with pulmonary fibrosis. Our study supports the potential benefit of targeting the PD-1/programmed death-ligand 1 pathway in the treatment of pulmonary fibrosis.
Association Between Severe Vitamin D Deficiency, Lung Function and Asthma Control.
Beyhan-Sagmen, Seda; Baykan, Ozgur; Balcan, Baran; Ceyhan, Berrin
2017-04-01
To examine the relationship between severe vitamin D deficiency, asthma control, and pulmonary function in Turkish adults with asthma. One hundred six asthmatic patients underwent pulmonary function tests skin prick test, peripheral blood eosinophil counts, IgE, body mass index and vitamin D levels were determined. Patients were divided into 2 subgroups according to vitamin D levels (vitamin D level<10ng/ml and vitamin D level≥10 ng/ml). Asthma control tests were performed. The mean age of subgroup i (vitamin D level<10) was 37±10 and the mean age of subgroup ii (vitamin D level≥10ng/ml) was 34±8. Sixty-six percent of patients had severe vitamin D deficiency (vitamin D level<10 ng/ml). There was a significant trend towards lower absolute FEV 1 (L) values in patients with lower vitamin D levels (P=.001). Asthma control test scores were significantly low in the severe deficiency group than the other group (P=.02). There were a greater number of patients with uncontrolled asthma (asthma control test scores<20) in the severe vitamin D deficiency group (P=.040). Patients with severe vitamin D deficiency had a higher usage of inhaled corticosteroids than the group without severe vitamin D deficiency (P=.015). There was a significant trend towards lower absolute FEV 1 (L) (P=.005, r=.272) values in patients with lower vitamin D levels. Vitamin D levels were inversely related with body mass index (P=.046). The incidence of severe vitamin D deficiency was high in adult Turkish asthmatics. In addition, lower vitamin D levels were associated with poor asthma control and decreased pulmonary function. Copyright © 2016 SEPAR. Publicado por Elsevier España, S.L.U. All rights reserved.
Pulmonary function in patients with Huntington’s Disease
2014-01-01
Background Huntington’s disease (HD) is a neurodegenerative disorder characterized by progressive motor, cognitive and psychiatric disturbances. Chest muscle rigidity, respiratory muscle weakness, difficulty in clearing airway secretions and swallowing abnormalities have been described in patients with neurodegenerative disorders including HD. However limited information is available regarding respiratory function in HD patients. The purpose of this study was to investigate pulmonary function of patients with HD in comparison to healthy volunteers, and its association with motor severity. Methods Pulmonary function measures were taken from 18 (11 male, 7 female) manifest HD patients (53 ± 10 years), and 18 (10 male, 8 female) healthy volunteers (52 ± 11 years) with similar anthropometric and life-style characteristics to the recruited HD patients. Motor severity was quantified by the Unified Huntington’s Disease Rating Scale-Total Motor Score (UHDRS-TMS). Maximum respiratory pressure was measured on 3 separate days with a week interval to assess test-retest reliability. Results The test-retest reliability of maximum inspiratory and expiratory pressure measurements was acceptable for both HD patient and control groups (ICC ≥0.92), but the values over 3 days were more variable in the HD group (CV < 11.1%) than in the control group (CV < 7.6%). The HD group showed lower respiratory pressure, forced vital capacity, peak expiratory flow and maximum voluntary ventilation than the control group (p < 0.05). Forced vital capacity, maximum voluntary ventilation and maximum respiratory pressures were negatively (r = -0.57; -0.71) correlated with the UHDRS-TMS (p < 0.05). Conclusion Pulmonary function is decreased in manifest HD patients, and the magnitude of the decrease is associated with motor severity. PMID:24886346
Tokuda, Mitsunori; Tabira, Kazuyuki; Masuda, Takashi; Nishiwada, Takashi; Shomoto, Koji
2014-07-01
This study aimed to evaluate the effectiveness of transcutaneous electrical nerve stimulation (TENS) for treatment of postoperative pain and pulmonary functions (vital capacity [VC]; cough peak flow, [CPF]) in patients who underwent abdominal surgery. Forty-eight patients were randomly allocated to receive TENS, placebo TENS, or no TENS (control) 1 hour a day for 3 days postoperatively. A 0-100 visual analog scale was used to assess pain at preintervention, mid-intervention, and postintervention on the third postoperative day. Pulmonary functions (VC, CPF) were evaluated by spirometer at preoperation (baseline) and at preintervention, mid-intervention, and postintervention on the third postoperative day. One-way analysis of variance was used to assess differences between groups at baseline. Mann-Whitney test was used to compare the control group with the placebo-TENS and TENS group, at each assessment timepoint. Two-way analysis of variance and Bonferroni post hoc test assessed the difference between the 2 (placebo-TENS×TENS) groups. A value of P<0.01 was considered statistically significant. The baselines were not significantly different between any groups. The TENS group had significant reductions in postoperative pain compared with the placebo group (P<0.01) and control group (P<0.01). There was also improvement in pulmonary functions (VC, CPF) at mid-TENS and post-TENS, but not in the placebo-TENS (P<0.01) or control groups (P<0.01). TENS is a valuable treatment to alleviate postoperative pain and improve pulmonary functions (ie, VC, CPF) in patients following abdominal surgery.
Exhaled breath condensate MMP-9 levels in children with bronchiectasis.
Karakoc, Gulbin Bingol; Inal, Ayfer; Yilmaz, Mustafa; Altintas, Derya Ufuk; Kendirli, Seval Guneser
2009-10-01
Bronchiectasis (BE) is still an important cause of chronic supurative respiratory diseases in developing countries. Neutrophil-derived proteases such as neutrophil elastase and matrix metalloproteases (MMPs) are implicated in causing airway damage in chronic pulmonary disease. In this study, we aimed to evaluate the MMP-9 and its natural tissue inhibitors of metalloproteinases (TIMP-1) levels utilizing the exhaled breath condensate (EBC) method and their relationship with radiological findings and pulmonary functions in children with BE.Thirty-eight children with BE and 12 healthy children were included: Group 1 (cystic fibrosis [CF] BE), Group 2 (non-CF BE), Group 3 (control group). High-resolution computerized tomography (HRCT) scores were calculated according to the anatomic extent of BE. Pulmonary function tests were performed, and MMP-9 and TIMP-1 levels in EBC were analyzed by ELISA.Exhaled breath condensate MMP-9 level was 48.9 +/- 26.8 ng/ml for Group 1, and for Group 2, 42.8 +/- 18.1 ng/ml; and for Group 3, 30 +/- 3.7 ng/ml. Although no statistically significant difference was found between the Groups 1 and 2, a significant difference was detected between these groups and controls. No statistically significant difference was found in TIMP-1 levels regarding all groups. EBC MMP-9 levels were inversely correlated with pulmonary functions test, and positively with HRCT scores and annual number of pulmonary infections.In conclusion, this study showed that EBC of children with both CF BE and non-CF BE contained higher levels of MMP-9 in comparison to controls. We suggest that EBC MMP-9 level may be a useful marker of airway injury in patients with BE however prospective studies are needed.
do Nascimento, Eloisa Sanches Pereira; Sampaio, Luciana Maria Malosá; Peixoto-Souza, Fabiana Sobral; Dias, Fernanda Dultra; Gomes, Evelim Leal Freitas Dantas; Greiffo, Flavia Regina; Ligeiro de Oliveira, Ana Paula; Stirbulov, Roberto; Vieira, Rodolfo Paula; Costa, Dirceu
2015-01-01
Chronic obstructive pulmonary disease (COPD) is a respiratory disease characterized by chronic airflow limitation that leads beyond the pulmonary changes to important systemic effects. COPD is characterized by pulmonary and systemic inflammation. However, increases in the levels of inflammatory cytokines in plasma are found even when the disease is stable. Pulmonary rehabilitation improves physical exercise capacity and quality of life and decreases dyspnea. The aim of this study was to evaluate whether a home-based pulmonary rehabilitation (HBPR) program improves exercise tolerance in COPD patients, as well as health-related quality of life and systemic inflammation. This prospective study was conducted at the Laboratory of Functional Respiratory Evaluation, Nove de Julho University, São Paulo, Brazil. After anamnesis, patients were subjected to evaluations of health-related quality of life and dyspnea, spirometry, respiratory muscle strength, upper limbs incremental test, incremental shuttle walk test, and blood test for quantification of systemic inflammatory markers (interleukin [IL]-6 and IL-8). At the end of the evaluations, patients received a booklet containing the physical exercises to be performed at home, three times per week for 8 consecutive weeks. Around 25 patients were enrolled, and 14 completed the pre- and post-HBPR ratings. There was a significant increase in the walked distance and the maximal inspiratory pressure, improvements on two components from the health-related quality-of-life questionnaire, and a decrease in plasma IL-8 levels after the intervention. The HBPR is an important and viable alternative to pulmonary rehabilitation for the treatment of patients with COPD; it improves exercise tolerance, inspiratory muscle strength, quality of life, and systemic inflammation in COPD patients.
Navarro, Carmen
2006-11-01
Pulmonary involvement in systemic sclerosis. Alveolitis, fibrosis and pulmonar arterial hypertension Lung disease is present in most of the patients with systemic sclerosis and is now the most important cause of mortality. Interstitial lung disease and pulmonary hypertension are, so far, the main disorders found and both are difficult to detect at the earliest stages. However, diagnostic tools such as immunological test, lung function test, high resolution CT, bronchoalveolar lavage, echocardiography, right-side cardiac catheterization, or lung biopsy are necessary to accurately evaluate the clinical status and allow to improve the management organ-specific ad hoc. Progress in immunological and vascular therapies as well as other emergence drugs offer new expectations to scleroderma patients. Copyright © 2006 Elsevier España S.L. Barcelona. Published by Elsevier Espana. All rights reserved.
Lung Oxidative Damage by Hypoxia
Araneda, O. F.; Tuesta, M.
2012-01-01
One of the most important functions of lungs is to maintain an adequate oxygenation in the organism. This organ can be affected by hypoxia facing both physiological and pathological situations. Exposure to this condition favors the increase of reactive oxygen species from mitochondria, as from NADPH oxidase, xanthine oxidase/reductase, and nitric oxide synthase enzymes, as well as establishing an inflammatory process. In lungs, hypoxia also modifies the levels of antioxidant substances causing pulmonary oxidative damage. Imbalance of redox state in lungs induced by hypoxia has been suggested as a participant in the changes observed in lung function in the hypoxic context, such as hypoxic vasoconstriction and pulmonary edema, in addition to vascular remodeling and chronic pulmonary hypertension. In this work, experimental evidence that shows the implied mechanisms in pulmonary redox state by hypoxia is reviewed. Herein, studies of cultures of different lung cells and complete isolated lung and tests conducted in vivo in the different forms of hypoxia, conducted in both animal models and humans, are described. PMID:22966417
Hassan, Megahed M; Hussein, Mona T; Emam, Ahmed Mamdouh; Rashad, Usama M; Rezk, Ibrahim; Awad, Al Hussein
2018-08-01
Optimal pulmonary air support is essential pre-requisite for efficient phonation. The objective is to correlate pulmonary and vocal functions in chronic obstructive pulmonary disease (COPD) to find out whether the reduced pulmonary function per se could induce dysphonia. In this prospective case-control study, sixty subjects with stable COPD underwent evaluation of pulmonary and vocal functions. The pulmonary functions measured include {Forced vital capacity (FVC), forced expiratory volume in the first second (FEV1), FEV1/FVC ratio, peak expiratory flow (PEF), maximum mid-expiratory flow (MMEF)}. The vocal functions were {jitter, shimmer, noise-to-harmonic ratio, pitch perturbation quotient, amplitude perturbation quotient, maximum phonation time (MPT), sound pressure level, phonatory efficiency, resistance and power. A control group (n=35) underwent the same measurements. These functions were compared between subjects and controls. Also, correlation of the vocal and pulmonary functions was conducted. Thirty five (58.3%) of COPD subjects have dysphonia. The pulmonary functions were lower in all COPD group than in the control group (P<0.001 for all parameters). Also, the FVC, FEV1, PEF and MMEF % of predicted values were significantly lower in subjects with dysphonia (n=35) than those without dysphonia (n=25) with P values 0.0018, <0.001, 0.0011 and 0.0026 respectively. In addition, the MPT in all subjects showed positive correlations to the 5 pulmonary functions (P=0.004 for FEV1/FVC ratio and P<0.001 for the rest). Also, the phonatory efficiency showed significant positive correlations with the pulmonary functions FVC, FEV1, PEF and MMEF (P=0.001, 0.001, 0.002 and 0.001 respectively). Unlike efficiency, the phonatory resistance revealed significant negative correlations with these pulmonary functions in the same order (P=0.001, 0.003, 0.002, 0.001 respectively). Dysphonia is a common comorbidity with COPD which attributed to multifactorial etiologies. The lower the pulmonary function in COPD patients is the more likely to have dysphonia. Decreased pulmonary function was associated with reduced MPT and phonatory efficiency but with increased phonatory resistance. The reduced pulmonary functions in COPD can be the underlying cause of the altered vocal function and dysphonia. Great part of this dysphonia is functional, and hence, can be corrected by voice therapy in compensated subjects. Further researches are needed to evaluate the efficacy of voice therapy in these patients. Copyright © 2017 Elsevier B.V. All rights reserved.
Fujii, Takeshi; Watanabe, Kota; Toyama, Yoshiaki; Matsumoto, Morio
2014-09-01
Case report. To describe a case in which a patient regained pulmonary function, assessed by ventilation-perfusion scans, after undergoing posterior vertebral column resection (VCR) to correct severe adolescent idiopathic scoliosis (AIS) with associated pulmonary dysfunction. Pulmonary improvement after corrective surgery for AIS has been reported. Ventilation-perfusion scans are useful for assessing pulmonary function. However, these scans have not been used to examine the recovery of pulmonary function after VCR for severe AIS with pulmonary dysfunction. A patient was described in whom ventilation-perfusion scans were used to examine improvements in impaired air ventilation and blood perfusion after VCR surgery for severe AIS. The relevant literature was reviewed. An 18-year-old male came to Keio University Hospital with exertional dyspnea associated with severe AIS. Radiographs showed severe scoliosis of 91° at T6-T12, and hypokyphosis of 6° at T5-T12. Computed tomographic scans showed narrowing of the thoracic cage on the convex side of the main thoracic curve, with the vertebral bodies at the apex of the curve obstructing the right main bronchus. Pulmonary function tests revealed a percent vital capacity of 44% and percent forced expiratory volume in 1 second of 76%. A ventilation-perfusion scan showed decreased air ventilation and blood perfusion in the right lung. The patient underwent posterior correction surgery, which used segmental pedicle screws with a VCR at T9. The scoliosis was corrected to 28°, and the kyphosis to 14°. Postoperative computed tomographic scans showed expansion of the right main bronchus. A ventilation-perfusion scan conducted 1 year after surgery showed clear improvement in both ventilation and blood perfusion in the right lung. The patient's forced expiratory volume in 1 second had increased to 91%. This is the first report in which ventilation-perfusion scans were used to examine improvements in impaired air ventilation and blood perfusion after VCR surgery in a patient with severe AIS. N/A.
Charalampopoulos, Athanasios; Gibbs, J Simon R; Davies, Rachel J; Gin-Sing, Wendy; Murphy, Kevin; Sheares, Karen K; Pepke-Zaba, Joanna; Jenkins, David P; Howard, Luke S
2016-09-01
We tested the hypothesis that patients with chronic thromboembolic pulmonary hypertension (CTEPH) that was deemed to be inoperable were more likely to respond to drugs for treating pulmonary arterial hypertension (PAH) by using cardiopulmonary exercise (CPX) testing than those with CTEPH that was deemed to be operable. We analyzed CPX testing data of all patients with CTEPH who were treated with PAH drugs and had undergone CPX testing before and after treatment at a single pulmonary hypertension center between February 2009 and March 2013. Suitability for pulmonary endarterectomy (PEA) was decided by experts in PEA who were associated with a treatment center. The group with inoperable CTEPH included 16 patients, the operable group included 26 patients. There were no differences in demographics and baseline hemodynamic data between the groups. Unlike patients in the operable group, after drug treatment patients with inoperable CTEPH had a significantly higher peak V̇o2 (P < 0.001), work load (P = 0.002), and oxygen pulse (P < 0.001). In terms of gas exchange, there was an overall net trend toward improved V̇e/V̇co2 in the group with inoperable CTEPH, with an increased PaCO2 (P = 0.01), suggesting reduced hyperventilation. No changes were observed in patients with operable CTEPH. In conclusion, treatment with PAH drug therapy reveals important pathophysiological differences between inoperable and operable CTEPH, with significant pulmonary vascular and cardiac responses in inoperable disease. Drug effects on exercise function observed in inoperable CTEPH cannot be translated to all forms of CTEPH. Copyright © 2016 the American Physiological Society.
Indoor mold exposure associated with neurobehavioral and pulmonary impairment: a preliminary report.
Kilburn, Kaye H
2003-07-01
Recently, patients who have been exposed indoors to mixed molds, spores, and mycotoxins have reported asthma, airway irritation and bleeding, dizziness, and impaired memory and concentration, all of which suggest the presence of pulmonary and neurobehavioral problems. The author evaluated whether such patients had measurable pulmonary and neurobehavioral impairments by comparing consecutive cases in a series vs. a referent group. Sixty-five consecutive outpatients exposed to mold in their respective homes in Arizona, California, and Texas were compared with 202 community subjects who had no known mold or chemical exposures. Balance, choice reaction time, color discrimination, blink reflex, visual fields, grip, hearing, problem-solving, verbal recall, perceptual motor speed, and memory were measured. Medical histories, mood states, and symptom frequencies were recorded with checklists, and spirometry was used to measure various pulmonary volumes and flows. Neurobehavioral comparisons were made after individual measurements were adjusted for age, educational attainment, and sex. Significant differences between groups were assessed by analysis of variance; a p value of less than 0.05 was used for all statistical tests. The mold-exposed group exhibited decreased function for balance, reaction time, blink-reflex latency, color discrimination, visual fields, and grip, compared with referents. The exposed group's scores were reduced for the following tests: digit-symbol substitution, peg placement, trail making, verbal recall, and picture completion. Twenty-one of 26 functions tested were abnormal. Airway obstructions were found, and vital capacities were reduced. Mood state scores and symptom frequencies were elevated. The author concluded that indoor mold exposures were associated with neurobehavioral and pulmonary impairments that likely resulted from the presence of mycotoxins, such as trichothecenes.
Respiratory effects of work in retail food stores. III. Pulmonary function findings.
Wegman, D H; Eisen, E A; Smith, T J; Greaves, I A; Fine, L J
1987-06-01
Findings are reported from a prospective morbidity study which examined the effects on pulmonary function associated with the particulate and gaseous air contaminants to which retail food store workers are exposed. A total of 685 supermarket employees (including meat wrappers, meat cutters and store clerks) performed standard ventilatory function tests [forced expiratory volume in 1 s (FEV1.0) and forced vital capacity (FVC)] during a base-line survey. Those available four years later (305) were resurveyed in a similar manner. A suggestive chronic effect on pulmonary function was shown in those with high cumulative exposures and allergic history. Among those workers who had continuous exposure to air contaminants in settings with "hot-wire" plastic wrap film cutters the annual rates of change in FEV1.0 and FVC were twice as great as the changes found among comparable workers who were not exposed to fumes from wrapping film. Those who switched from the "hot-wire" to the "cool-rod" cutters during the course of the follow-up had intermediate rates of change in lung function.
Benefits from the correction of vitamin D deficiency in patients with pulmonary hypertension.
Mirdamadi, Ahmad; Moshkdar, Pouya
2016-01-01
Vitamin D (Vit D) is linked to various conditions including musculoskeletal, metabolic and cardiopulmonary diseases. However, it is not clear whether correction of vit D deficiency exerts any beneficial effect in patients with pulmonary hypertension. This study was a prospective uncontrolled longitudinal study. Patients with pulmonary hypertension and vit D deficiency were enrolled into this study. All patients in addition to standard treatment for pulmonary hypertension received cholecalciferol at a dose of 50,000 IU weekly plus calcicare (at a dose of 200 mg magnesium + 8 mg zinc + 400 IU vit D) daily for 3 months. Serum level of 25-hydroxy vit D, serum level of pro-brain natriuretic peptide, six minute walk test (6MWT), peak and mean pulmonary artery pressure, right ventricular size and function, ejection fraction (EF) and New York Heart Association (NYHA) functional class were measured at baseline and after 3 months of treatment. Twenty-two patients with pulmonary hypertension and vit D deficiency were enrolled into the study. At endpoint, the serum vit D level increased significantly to 54.8 ng/ml, the mean of baseline distance of 6MWT increased significantly to 81.6 m and the RV size significantly improved. The mean pulmonary artery pressure also improved after the intervention, but their changes did not reach to statistically significant levels. Vit D replacement therapy in patients with pulmonary arterial hypertension and vit D deficiency results in significant improvement of right ventricular size and 6 MWT. Moreover, mean pulmonary artery pressure improves nonsignificantly. This issue requires further studies with long-term follow-up period.
Froeling, Vera; Heimann, Uwe; Huebner, Ralf-Harto; Kroencke, Thomas J; Maurer, Martin H; Doellinger, Felix; Geisel, Dominik; Hamm, Bernd; Brenner, Winfried; Schreiter, Nils F
2015-07-01
To evaluate the utility of attenuation correction (AC) of V/P SPECT images for patients with pulmonary emphysema. Twenty-one patients (mean age 67.6 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. AC/non-AC V/P SPECT images were compared visually and semiquantitatively. Visual comparison of AC/non-AC images was based on a 5-point likert scale. Semiquantitative comparison assessed absolute counts per lung (aCpLu) and lung lobe (aCpLo) for AC/non-AC images using software-based analysis; percentage counts (PC = (aCpLo/aCpLu) × 100) were calculated. Correlation between AC/non-AC V/P SPECT images was analyzed using Spearman's rho correlation coefficient; differences were tested for significance with the Wilcoxon rank sum test. Visual analysis revealed high conformity for AC and non-AC V/P SPECT images. Semiquantitative analysis of PC in AC/non-AC images had an excellent correlation and showed no significant differences in perfusion (ρ = 0.986) or ventilation (ρ = 0.979, p = 0.809) SPECT/CT images. AC of V/P SPECT images for lung lobe-based function imaging in patients with pulmonary emphysema do not improve visual or semiquantitative image analysis.
Rafiq, Rachida; Prins, Hendrik J; Boersma, Wim G; Daniels, Johannes Ma; den Heijer, Martin; Lips, Paul; de Jongh, Renate T
2017-01-01
Although vitamin D is well known for its function in calcium homeostasis and bone mineralization, several studies have shown positive effects on muscle strength and physical function. In addition, vitamin D has been associated with pulmonary function and the incidence of airway infections. As vitamin D deficiency is highly prevalent in chronic obstructive pulmonary disease (COPD) patients, supplementation might have a beneficial effect in these patients. To assess the effect of vitamin D supplementation on respiratory muscle strength and physical performance in vitamin D-deficient COPD patients. Secondary outcomes are pulmonary function, handgrip strength, exacerbation rate, and quality of life. We performed a randomized, double-blind, placebo-controlled pilot trial. Participants were randomly allocated to receive 1,200 IU vitamin D3 per day (n=24) or placebo (n=26) during 6 months. Study visits were conducted at baseline, and at 3 and 6 months after randomization. During the visits, blood was collected, respiratory muscle strength was measured (maximum inspiratory and expiratory pressure), physical performance and 6-minute walking tests were performed, and handgrip strength and pulmonary function were assessed. In addition, participants kept a diary card in which they registered respiratory symptoms. At baseline, the mean (standard deviation [SD]) serum 25-hydroxyvitamin D (25(OH)D) concentration (nmol/L) was 42.3 (15.2) in the vitamin D group and 40.6 (17.0) in the placebo group. Participants with vitamin D supplementation had a larger increase in serum 25(OH)D compared to the placebo group after 6 months (mean difference (SD): +52.8 (29.8) vs +12.3 (25.1), P <0.001). Primary outcomes, respiratory muscle strength and physical performance, did not differ between the groups after 6 months. In addition, no differences were found in the 6-minute walking test results, handgrip strength, pulmonary function, exacerbation rate, or quality of life. Vitamin D supplementation did not affect (respiratory) muscle strength or physical performance in this pilot trial in vitamin D-deficient COPD patients.
Long-Term Pulmonary Function in Survivors of Childhood Cancer
Armenian, Saro H.; Landier, Wendy; Francisco, Liton; Herrera, Claudia; Mills, George; Siyahian, Aida; Supab, Natt; Wilson, Karla; Wolfson, Julie A.; Horak, David; Bhatia, Smita
2015-01-01
Purpose This study was undertaken to determine the magnitude of pulmonary dysfunction in childhood cancer survivors when compared with healthy controls and the extent (and predictors) of decline over time. Patients and Methods Survivors underwent baseline (t1) pulmonary function tests, followed by a second comprehensive evaluation (t2) after a median of 5 years (range, 1.0 to 10.3 years). Survivors were also compared with age- and sex-matched healthy controls at t2. Results Median age at cancer diagnosis was 16.5 years (range, 0.2 to 21.9 years), and time from diagnosis to t2 was 17.1 years (range, 6.3 to 40.1 years). Compared with odds for healthy controls, the odds of restrictive defects were increased 6.5-fold (odds ratio [OR], 6.5; 95% CI, 1.5 to 28.4; P < .01), and the odds of diffusion abnormalities were increased 5.2-fold (OR, 5.2; 95% CI, 1.8 to 15.5; P < .01). Among survivors, age younger than 16 years at diagnosis (OR, 3.0; 95% CI, 1.2 to 7.8; P = .02) and exposure to more than 20 Gy chest radiation (OR, 5.6; 95% CI, 1.5 to 21.0; P = .02, referent, no chest radiation) were associated with restrictive defects. Female sex (OR, 3.9; 95% CI, 1.7 to 9.5; P < .01) and chest radiation dose (referent: no chest radiation; ≤ 20 Gy: OR, 6.4; 95% CI, 1.7 to 24.4; P < .01; > 20 Gy: OR, 11.3; 95% CI, 2.6 to 49.5; P < .01) were associated with diffusion abnormalities. Among survivors with normal pulmonary function tests at t1, females and survivors treated with more than 20 Gy chest radiation demonstrated decline in diffusion function over time. Conclusion Childhood cancer survivors exposed to pulmonary-toxic therapy are significantly more likely to have restrictive and diffusion defects when compared with healthy controls. Diffusion capacity declines with time after exposure to pulmonary-toxic therapy, particularly among females and survivors treated with high-dose chest radiation. These individuals could benefit from subsequent monitoring. PMID:25847925
21 CFR 868.1890 - Predictive pulmonary-function value calculator.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Predictive pulmonary-function value calculator. 868.1890 Section 868.1890 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... pulmonary-function value calculator. (a) Identification. A predictive pulmonary-function value calculator is...
21 CFR 868.1890 - Predictive pulmonary-function value calculator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Predictive pulmonary-function value calculator. 868.1890 Section 868.1890 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... pulmonary-function value calculator. (a) Identification. A predictive pulmonary-function value calculator is...
Shah, Dilip; Romero, Freddy; Duong, Michelle; Wang, Nadan; Paudyal, Bishnuhari; Suratt, Benjamin T; Kallen, Caleb B; Sun, Jianxin; Zhu, Ying; Walsh, Kenneth; Summer, Ross
2015-06-12
Obesity is a risk factor for the development of acute respiratory distress syndrome (ARDS) but mechanisms mediating this association are unknown. While obesity is known to impair systemic blood vessel function, and predisposes to systemic vascular diseases, its effects on the pulmonary circulation are largely unknown. We hypothesized that the chronic low grade inflammation of obesity impairs pulmonary vascular homeostasis and primes the lung for acute injury. The lung endothelium from obese mice expressed higher levels of leukocyte adhesion markers and lower levels of cell-cell junctional proteins when compared to lean mice. We tested whether systemic factors are responsible for these alterations in the pulmonary endothelium; treatment of primary lung endothelial cells with obese serum enhanced the expression of adhesion proteins and reduced the expression of endothelial junctional proteins when compared to lean serum. Alterations in pulmonary endothelial cells observed in obese mice were associated with enhanced susceptibility to LPS-induced lung injury. Restoring serum adiponectin levels reversed the effects of obesity on the lung endothelium and attenuated susceptibility to acute injury. Our work indicates that obesity impairs pulmonary vascular homeostasis and enhances susceptibility to acute injury and provides mechanistic insight into the increased prevalence of ARDS in obese humans.
Shah, Dilip; Romero, Freddy; Duong, Michelle; Wang, Nadan; Paudyal, Bishnuhari; Suratt, Benjamin T.; Kallen, Caleb B.; Sun, Jianxin; Zhu, Ying; Walsh, Kenneth; Summer, Ross
2015-01-01
Obesity is a risk factor for the development of acute respiratory distress syndrome (ARDS) but mechanisms mediating this association are unknown. While obesity is known to impair systemic blood vessel function, and predisposes to systemic vascular diseases, its effects on the pulmonary circulation are largely unknown. We hypothesized that the chronic low grade inflammation of obesity impairs pulmonary vascular homeostasis and primes the lung for acute injury. The lung endothelium from obese mice expressed higher levels of leukocyte adhesion markers and lower levels of cell-cell junctional proteins when compared to lean mice. We tested whether systemic factors are responsible for these alterations in the pulmonary endothelium; treatment of primary lung endothelial cells with obese serum enhanced the expression of adhesion proteins and reduced the expression of endothelial junctional proteins when compared to lean serum. Alterations in pulmonary endothelial cells observed in obese mice were associated with enhanced susceptibility to LPS-induced lung injury. Restoring serum adiponectin levels reversed the effects of obesity on the lung endothelium and attenuated susceptibility to acute injury. Our work indicates that obesity impairs pulmonary vascular homeostasis and enhances susceptibility to acute injury and provides mechanistic insight into the increased prevalence of ARDS in obese humans. PMID:26068229
du Bois, Roland M; Weycker, Derek; Albera, Carlo; Bradford, Williamson Z; Costabel, Ulrich; Kartashov, Alex; Lancaster, Lisa; Noble, Paul W; Sahn, Steven A; Szwarcberg, Javier; Thomeer, Michiel; Valeyre, Dominique; King, Talmadge E
2011-05-01
The 6-minute-walk test (6MWT) is a practical and clinically meaningful measure of exercise tolerance with favorable performance characteristics in various cardiac and pulmonary diseases. Performance characteristics in patients with idiopathic pulmonary fibrosis (IPF) have not been systematically evaluated. To assess the reliability, validity, and responsiveness of the 6MWT and estimate the minimal clinically important difference (MCID) in patients with IPF. The study population included all subjects completing a 6MWT in a clinical trial evaluating interferon gamma-1b (n = 822). Six-minute walk distance (6MWD) and other parameters were measured at baseline and at 24-week intervals using a standardized protocol. Parametric and distribution-independent correlation coefficients were used to assess the strength of the relationships between 6MWD and measures of pulmonary function, dyspnea, and health-related quality of life. Both distribution-based and anchor-based methods were used to estimate the MCID. Comparison of two proximal measures of 6MWD (mean interval, 24 d) demonstrated good reliability (coefficient = 0.83; P < 0.001). 6MWD was weakly correlated with measures of physiologic function and health-related quality of life; however, values were consistently and significantly lower for patients with the poorest functional status, suggesting good construct validity. Importantly, change in 6MWD was highly predictive of mortality; a 24-week decline of greater than 50 m was associated with a fourfold increase in risk of death at 1 year (hazard ratio, 4.27; 95% confidence interval, 2.57- 7.10; P < 0.001). The estimated MCID was 24-45 m. The 6MWT is a reliable, valid, and responsive measure of disease status and a valid endpoint for clinical trials in IPF.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koenig, J.Q.; Covert, D.S.; Larson, T.V.
To evaluate the pulmonary effects of varying doses of sulfuric acid, adolescent subjects with asthma were exposed to 35 or 70 micrograms/m3 sulfuric acid for 45 or 90 min. Exposure was carried out during intermittent moderate exercise. The pulmonary functions measured before and after exposure were FEV1, FVC, and total respiratory resistance. The 45 min exposures were associated with larger decreases in FEV1 (-6% or -3%) than the 90 min exposures (-1% or +2%). Analysis of variance of the change in FEV1 among the exposures revealed that the 45 min exposure to 35 micrograms/m3 was significant (p = 0.03). Themore » p value for 45 min exposure to 70 micrograms/m3 was not significant (p = 0.08). Using analysis of variance, neither of the 90 min exposures was associated with a significant decrease in FEV1 compared to air exposure. Also, none of the changes in FVC or RT was significant. When baseline to post-exposure changes were compared for each of the five test atmospheres using paired t tests, both of the 45 min exposures were associated with statistical significance (p < 0.001 for 35 micrograms/m3 and p < 0.005 for 70 micrograms/m3). This baseline to post exposure change was not statistically significant for the 90 min exposures. The reason for the lesser effect on pulmonary function at increased exposure duration is not known; it may be due to changes in either varying deposition patterns or changes in buffering capacity of the cells lining the airways. With respect to individual sensitivities to H2SO4, the data showed a significant consistency across test atmospheres.« less
Zhang, C; Zhu, Y; Li, Q Q; Gu, H
2018-06-02
Objective: To investigate the risk factors, clinical features, treatments, and prevention of pulmonary hypertensive crisis (PHC) in children with idiopathic pulmonary arterial hypertension (IPAH) undergoing cardiac catheterization. Methods: This retrospective study included 67 children who were diagnosed with IPAH and underwent cardiac catheterization between April 2009 and June 2017 in Beijing Anzhen Hospital. The medical histories, clinical manifestations, treatments, and outcomes were characterized. Statistical analyses were performed using t test, χ(2) test and a multiple Logistic regression analysis. Results: During cardiac catheterization, five children developed PHC who presented with markedly elevated pulmonary artery pressure and central venous pressure, decline in systemic arterial pressure and oxygen saturation. Heart rate decreased in 4 cases and increased in the remaining one. After the treatments including cardiopulmonary resuscitation, pulmonary vasodilator therapy, improving cardiac output and blood pressure, and correction of acidosis, 4 of the 5 cases recovered, while 1 died of severe right heart failure with irreversible PHC 3 days after operation. Potential PHC was considered in 7 other patients, whose pulmonary artery pressure increased and exceeded systemic arterial pressure, oxygen saturation decreased, and central venous pressure and vital signs were relatively stable. Univariate analysis showed that the risk factors of PHC in children with IPAH undergoing cardiac catheterization were younger age ( t= 3.160, P= 0.004), low weight ( t= 4.004, P< 0.001), general anesthesia (χ(2)=4.970, P= 0.026), history of syncope (χ(2)=4.948, P= 0.026), and WHO cardiac functional class Ⅲ or Ⅳ (χ(2)=19.013, P< 0.001). Multivariate Logistic regression analysis revealed that worse WHO cardiac functional class ( Wald =13.128, P< 0.001, OR= 15.076, 95% CI : 3.475-65.418) was the independent risk factor of PHC. Conclusions: PHC is a severe and extremely dangerous complication in children with IPAH during cardiac catheterization. WHO cardiac functional class may be associated with PHC. Integrated treatment is required for these patients. Reducing risk factors, early identification, and active treatment may help to prevent the occurrence and progression of PHC.
Screening adolescent athletes for exercise-induced asthma.
Feinstein, R A; LaRussa, J; Wang-Dohlman, A; Bartolucci, A A
1996-04-01
To pilot test an exercise-induced asthma (EIA) screening program using a submaximal step-test and pulmonary function test (PFT) to identify athletes with EIA and to determine if a physical examination or self-reported history could be used to predict the existence of EIA. Screening and diagnostic testing using a convenience sample. Birmingham, Alabama, during athletic preparticipation examination (PPE). Fifty-two African-American, male football players aged 14-18 years being evaluated for participation in scholastic athletics. No athlete refused participation. Four were excluded because of need for further evaluation unrelated to any pulmonary condition. Each athlete completed a medical history, allergy history, physical examination, preexercise pulmonary function test (PFT), submaximal step-test, and a series of postexercise PFTs. Major outcome measurements were changes in forced expiration volume in 1s (FEV1) or peak expiratory flow rate (PEFR) after completing an exercise challenge. Seventeen of 48 athletes had a > or = 15% decrease in PEFR after exercise. Nine of 48 athletes had a > or = 15% decrease in FEV1 after exercise. The only self-reported item that differentiated subjects with normal and abnormal PFTs was a personal history of asthma (p < 0.05). Many athletes can be identified as having abnormal PFTs by use of a submaximal step-test as an exercise challenge. Self-reporting questionnaires and PPEs do not appear to be sensitive enough to identify athletes with this condition. If validated by future studies, this protocol could be used for the diagnosis of EIA.
Sensitive subgroups and normal variation in pulmonary function response to air pollution episodes.
Brunekreef, B; Kinney, P L; Ware, J H; Dockery, D; Speizer, F E; Spengler, J D; Ferris, B G
1991-01-01
The Clean Air Act requires that sensitive subgroups of exposed populations be protected from adverse health effects of air pollution exposure. Hence, data suggesting the existence of sensitive subgroups can have an important impact on regulatory decisions. Some investigators have interpreted differences among individuals in observed pulmonary function response to air pollution episodes as evidence that individuals differ in their sensitivity. An alternative explanation is that the differences are due entirely to normal variation in repeated pulmonary function measurements. This paper investigates this question by reanalyzing data from three studies of children exposed to air pollution episodes to determine whether the observed variability in pulmonary function response indicates differences in sensitivity or natural interoccasion variability. One study investigated exposures to total suspended particulates (TSP), the other two investigated exposure to ozone. In all studies, each child's response to air pollution exposures was summarized by regressing that child's set of pulmonary function measurements on the air pollution concentrations on the day or days before measurement. The within-child and between-child variances of these slopes were used to test the hypothesis of variable sensitivity. Regression slopes did not vary significantly among children exposed to episodes of high TSP concentration, but there was evidence of heterogeneity in both studies of ozone exposures. The finding of heterogeneous response to ozone exposure is consistent with the epidemiologic and chamber studies of ozone exposures, but the lack of evidence for heterogeneous response to TSP exposures implies that observed variation in response can be explained by sampling variability rather than the presence of sensitive subgroup. PMID:2050060
Respiratory parameters in elite athletes--does sport have an influence?
Mazic, S; Lazovic, B; Djelic, M; Suzic-Lazic, J; Djordjevic-Saranovic, S; Durmic, T; Soldatovic, I; Zikic, D; Gluvic, Z; Zugic, V
2015-01-01
Unlike large population studies about cardiovascular components and how they adapt to intensive physical activity, there is less research into the causes of enlargement of the respiratory system in athletes (e.g. vital capacity, maximum flow rates and pulmonary diffusion capacity). The purpose of this research was to study and compare pulmonary function in different types of sports and compare them with controls in order to find out which sports improve lung function the most. Pulmonary functional capacities, vital capacity (VC), forced vital capacity (FVC), forced expiratory volume in one second (FEV1) and maximum voluntary ventilation (MVV) of 493 top athletes belonging to 15 different sports disciplines and of 16 sedentary individuals were studied. Pulmonary function test was performed according to ATS/ERS guidelines. Basketball, water polo players and rowers had statistically higher vital capacity (VC), forced vital capacity (FVC), forced expiratory volume in one second (FEV1) than the healthy sedentary control individuals. Football and volleyball players had lower VC while FVC was higher in the football group compared to controls. Peak expiratory flow was lower in boxing, kayak, rugby, handball, taekwondo and tennis. The maximum voluntary ventilation (MVV) was significantly higher in water polo players and rowers. Boxers had statistically lower MVV than the controls. Players of other sports did not differ from the control group. The study suggests that specific type of training used in basketball, water polo or rowing could have potential for improving pulmonary function and rehabilitation. Copyright © 2014 Sociedade Portuguesa de Pneumologia. Published by Elsevier España, S.L.U. All rights reserved.
The efficacy of incentive spirometry in patients with COPD.
Basoglu, Ozen Kacmaz; Atasever, Alev; Bacakoglu, Feza
2005-06-01
Although incentive spirometry (IS) is frequently used to prevent postoperative pulmonary complications, its efficacy in patients with COPD has not been documented. The aim of this study was to evaluate the effects of IS on pulmonary function tests, arterial blood gases, dyspnoea and health-related quality of life in patients hospitalized for COPD. A total of 27 consecutive patients (mean age, 68.4 +/- 7.9 years; 26 males) admitted for COPD exacerbations were recruited for the study. In total, 15 (IS treatment group) used IS for 2 months, together with medical treatment. The remaining 12 (medical treatment group) were given only medical treatment. Pulmonary function and blood gases were measured. Assessment of dyspnoea by visual analogue scale (VAS) and quality of life using the St. George's Respiratory Questionnaire (SGRQ) were performed at admission and after 2 months of treatment. The activity, impact and total scores for the SGRQ improved (all P < or = 0.0001), PaCO2 values decreased (P = 0.02), PaO2 and PAO2 values increased (P = 0.02 and P = 0.01, respectively) in the IS treatment group. However, there were no significant differences between the measurements made pretreatment and after 2 months of medical therapy in the medical treatment group, with regards to pulmonary function, blood gases, SGRQ scores and VAS. The use of IS appears to improve arterial blood gases and health-related quality of life in patients with COPD exacerbations, although it does not alter pulmonary function parameters.
Abnormal Pulmonary Function in Adults with Sickle Cell Anemia
Klings, Elizabeth S.; Wyszynski, Diego F.; Nolan, Vikki G.; Steinberg, Martin H.
2006-01-01
Rationale: Pulmonary complications of sickle cell anemia (Hb-SS) commonly cause morbidity, yet few large studies of pulmonary function tests (PFTs) in this population have been reported. Objectives: PFTs (spirometry, lung volumes, and diffusion capacity for carbon monoxide [DLCO]) from 310 adults with Hb-SS were analyzed to determine the pattern of pulmonary dysfunction and their association with other systemic complications of sickle cell disease. Methods: Raw PFT data were compared with predicted values. Each subject was subclassified into one of five groups: obstructive physiology, restrictive physiology, mixed obstructive/restrictive physiology, isolated low DLCO, or normal. The association between laboratory data of patients with decreased DLCO or restrictive physiology and those of normal subjects was assessed by multivariate linear regression. Measurements and Main Results: Normal PFTs were present in only 31 of 310 (10%) patients. Overall, adults with Hb-SS were characterized by decreased total lung capacities (70.2 ± 14.7% predicted) and DlCO (64.5 ± 19.9%). The most common PFT patterns were restrictive physiology (74%) and isolated low DlCO (13%). Decreased DLCO was associated with thrombocytosis (p = 0.05), with hepatic dysfunction (elevated alanine aminotransferase; p = 0.07), and a trend toward renal dysfunction (elevated blood urea nitrogen and creatinine; p = 0.05 and 0.07, respectively). Conclusions: Pulmonary function is abnormal in 90% of adult patients with Hb-SS. Common abnormalities include restrictive physiology and decreased DLCO. Decreased DLCO may indicate more severe sickle vasculopathy characterized by impaired hepatic and renal function. PMID:16556694
Ussavarungsi, Kamonpun; Lee, Augustine S; Burger, Charles D
2016-09-01
Pulmonary hypertension (PH) is commonly observed in patients with diffuse parenchymal lung disease (DPLD). The purpose of this study was to explore the influence of the 6-minute walk test (6MWT) as a simple, non-invasive tool to assess right ventricular (RV) function in patients with DPLD and to identify the need for an echocardiogram (ECHO) to screen for PH. We retrospectively reviewed 48 patients with PH secondary to DPLD, who were evaluated in the PH clinic at the Mayo Clinic in Jacksonville, Florida, from January 1999 to December 2014. Fifty-two percent of patients had RV dysfunction. They had a significantly greater right heart pressure by ECHO and mean pulmonary arterial pressure (MPAP) from right heart catheterization (RHC) than those with normal RV function. A reduced 6-minute walk distance (6MWD) did not predict RV dysfunction (OR 0.995; 95% CI 0.980-1.001, p = 0.138). In addition, worsening restrictive physiology, heart rate at one-minute recovery and desaturation were not different between patients with and without RV dysfunction. However, there were inverse correlations between 6MWD and MPAP from RHC (r = -0.41, p = 0.010), 6MWD and RV systolic pressure (r = -0.51, p < 0.001), and 6MWD and MPAP measured by ECHO (r = -0.46, p =0.013). We also found no significant correlation between 6MWD and pulmonary function test parameters. Our single-center cohort of patients with PH secondary to DPLD, PH was found to have an impact on 6MWD. In contrast to our expectations, 6MWD was not useful to predict RV dysfunction. Interestingly, a severe reduction in the 6MWD was related to PH and not to pulmonary function; therefore, it may be used to justify an ECHO to identify patients with a worse prognosis.
Burkholder, David; Hadi, Duraid; Kunnavakkam, Rangesh; Kindler, Hedy; Todd, Kristy; Celauro, Amy Durkin; Vigneswaran, Wickii T
2015-05-01
Maximal cytoreductive surgeries--extrapleural pneumonectomy and extended pleurectomy and decortication (EPD)--are effective surgical treatments in selected patients with malignant pleural mesothelioma. Extended pleurectomy and decortication results in equivalent survival yet better health-related quality of life (HRQoL). Patients with malignant pleural mesothelioma were studied for the effects of EPD on HRQoL and pulmonary function. The European Organization for Research and Treatment of Cancer Core Quality of Life Questionaire-C30 was used to evaluate HRQoL before operation, and at 4 to 5 and 7 to 8 months postoperatively. Pulmonary function tests were measured immediately before and 5 to 7 months after the operation. Patients were compared according to World Health Organization baseline performance status (PS). Of the 36 patients enrolled, 17 were PS 0 and 19 were PS 1 or PS 2 at baseline. Patients in groups PS 1 and PS 2 had significantly worse global health, functional, and symptoms scores. After EPD, PS 0 patients had no change in global health or function and symptoms scores except for emotional function, whereas PS 1 or PS 2 patients showed improvements at 4 to 5 months with further improvements at 7 to 8 months. The PS 0 patients demonstrated a significant decrease in forced vital capacity (p = 0.001), forced expiratory volume in 1 second (p = 0.002), total lung capacity (p = 0.0006) and diffusing capacity of the lung for carbon monoxide (p = 0.003) after EPD, whereas no change was observed in PS 1 and PS 2 patients. Extended pleurectomy and decortication did not improve overall HRQoL and had a negative impact in pulmonary function in minimally symptomatic patients. In symptomatic patients, a significant improvement in HRQoL was observed after EPD, which continued at late follow-up, although the pulmonary function was not affected. As changes in HRQoL are multidimensional, the preservation of the pulmonary function may have contributed to the net benefit observed in PS 1 and PS 2 patients. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Acute effects of inspiratory muscle warm-up on pulmonary function in healthy subjects.
Özdal, Mustafa
2016-06-15
The acute effects of inspiratory muscle warm-up on pulmonary functions were examined in 26 healthy male subjects using the pulmonary function test (PFT) in three different trials. The control trial (CON) did not involve inspiratory muscle warm-up, while the placebo (IMWp) and experimental (IMW) trials involved inspiratory muscle warm-up. There were no significant changes between the IMWp and CON trials (p>0.05). All the PFT measurements, including slow vital capacity, inspiratory vital capacity, forced vital capacity, forced expiratory volume in one second, maximal voluntary ventilation, and maximal inspiratory pressure were significantly increased by 3.55%, 12.52%, 5.00%, 2.75%, 2.66%, and 7.03% respectively, in the subjects in the IMW trial than those in the CON trial (p<0.05). These results show that inspiratory muscle warm-up improved the pulmonary functions. The mechanisms responsible for these improvements are probably associated with the concomitant increase in the inspiratory muscle strength, and the cooperation of the upper thorax, neck, and respiratory muscles, and increased level of reactive O2 species in muscle tissue, and potentially improvement of muscle O2 delivery-to-utilization. However, further investigation is required to determine the precise mechanisms responsible from among these candidates. Copyright © 2016 Elsevier B.V. All rights reserved.
Darocha, Szymon; Pietura, Radosław; Pietrasik, Arkadiusz; Norwa, Justyna; Dobosiewicz, Anna; Piłka, Michał; Florczyk, Michał; Biederman, Andrzej; Torbicki, Adam; Kurzyna, Marcin
2017-03-24
The effect of balloon pulmonary angioplasty (BPA) on improvement in functional and hemodynamic parameters in chronic thromboembolic pulmonary hypertension (CTEPH) is known, but the quality of life (QoL) of patients treated with BPA has never been studied before.Methods and Results:Twenty-five patients with inoperable or persistent CTEPH were enrolled in the study and filled out the 36-item Short Form (SF-36v2) questionnaire twice: prior to commencement of BPA treatment and after ≥3 BPA sessions. In addition WHO functional class, distance on the 6-min walk test (6MWT) and hemodynamic parameters such as right atrial pressure (RAP), mean pulmonary artery pressure (mPAP), cardiac index (CI) and pulmonary vascular resistance (PVR) were assessed. QoL improved significantly in all domains, except for physical pain. Improvement in RAP (10.5±3.4 vs. 6.2±2.2 mmHg; P<0.05), mPAP (51.7±10.6 vs. 35.0±9.1 mmHg; P<0.05), CI (2.2±0.5 vs. 2.5±0.4 L/min·m 2 ; P=0.04), PVR (10.4±3.9 vs. 5.5±2.2 Wood units; P<0.05), functional class (96% vs. 20% in WHO class III and IV, P<0.05) and improvement in 6MWT distance (323±135 vs. 410±109 m; P<0.05) was observed. The only significant correlation was between the mental component summary score of QoL after completion of treatment and percentage improvement in the 6MWT (-0.404, P<0.05). Alongside improvement in functional and hemodynamic parameters, BPA also provides significant improvement in QoL.
Gavini, S; Borges, L F; Finn, R T; Lo, W-K; Goldberg, H J; Burakoff, R; Feldman, N; Chan, W W
2017-05-01
Gastroesophageal reflux (GER) has been associated with idiopathic pulmonary fibrosis (IPF). Pathogenesis may be related to chronic micro-aspiration. We aimed to assess objective measures of GER on multichannel intraluminal impedance and pH study (MII-pH) and their relationship with pulmonary function testing (PFT) results, and to compare the performance of pH/acid reflux parameters vs corresponding MII/bolus parameters in predicting pulmonary dysfunction in IPF. This was a retrospective cohort study of IPF patients undergoing prelung transplant evaluation with MII-pH off acid suppression, and having received PFT within 3 months. Patients with prior fundoplication were excluded. Severe pulmonary dysfunction was defined using diffusion capacity of the lung for carbon monoxide (DLCO) ≤40%. Six pH/acid reflux parameters with corresponding MII/bolus reflux measures were specified a priori. Multivariate analyses were applied using forward stepwise logistic regression. Predictive value of each parameter for severe pulmonary dysfunction was calculated by area-under-the-receiver-operating-characteristic-curve or c-statistic. Forty-five subjects (67% M, age 59, 15 mild-moderate vs 30 severe) met criteria for inclusion. Patient demographics and clinical characteristics were similar between pulmonary dysfunction groups. Abnormal total reflux episodes and prolonged bolus clearance time were significantly associated with pulmonary dysfunction severity on univariate and multivariate analyses. No pH parameters were significant. The c-statistic of each pH parameter was lower than its MII counterpart in predicting pulmonary dysfunction. MII/bolus reflux, but not pH/acid reflux, was associated with pulmonary dysfunction in prelung transplant patients with IPF. MII-pH may be more valuable than pH testing alone in characterizing GER in IPF. © 2016 John Wiley & Sons Ltd.
MFAP4: a candidate biomarker for hepatic and pulmonary fibrosis?
Mölleken, Christian; Poschmann, Gereon; Bonella, Francesco; Costabel, Ulrich; Sitek, Barbara; Stühler, Kai; Meyer, Helmut E; Schmiegel, Wolff H; Marcussen, Niels; Helmer, Michael; Nielsen, Ole; Hansen, Søren; Schlosser, Anders; Holmskov, Uffe; Sorensen, Grith Lykke
2016-03-29
Several comparable mechanisms have been identified for hepatic and pulmonary fibrosis. The human microfibrillar associated glycoprotein 4 (MFAP4), produced by activated myofibroblasts, is a ubiquitous protein playing a potential role in extracellular matrix (ECM) turnover and was recently identified as biomarker for hepatic fibrosis in hepatitis C patients. The current study aimed to evaluate serum levels of MFAP4 in patients with pulmonary fibrosis in order to test its potential as biomarker in clinical practice. A further aim was to determine whether MFAP4 deficiency in mice affects the formation of pulmonary fibrosis in the bleomycin model of lung fibrosis. 91 patients with idiopathic pulmonary fibrosis (IPF), 23 with hypersensitivity pneumonitis (HP) and 31 healthy subjects were studied. In the mouse model, C57BL/6 Mfap4+/+ and Mfap4-/- mice between 6-8 weeks of age were studied. Serum levels of MFAP4 were measured by ELISA in patients and in mice. Surfactant protein D (SP-D) and LDH were measured as comparison biomarkers in patients with pulmonary fibrosis. Morphometric assessment and the Sircol kit were used to determine the amount of collagen in the lung tissue in the mouse model. Serum levels of MFAP4 were not elevated in lung fibrosis - neither in the patients with IPF or HP nor in the animal model. Furthermore no significant correlations with pulmonary function tests of IPF patients could be found for MFAP4. MFAP4 levels were increased in BAL of bleomycin treated mice with pulmonary fibrosis. MFAP4 is not elevated in sera of patients with pulmonary fibrosis or bleomycin treated mice with pulmonary fibrosis. This may be due to different pathogenic mechanisms of liver and lung fibrogenesis. MFAP4 seems to be useful as serum biomarker for hepatic but not for lung fibrosis.
Respiratory function in facioscapulohumeral muscular dystrophy 1.
Wohlgemuth, M; Horlings, C G C; van der Kooi, E L; Gilhuis, H J; Hendriks, J C M; van der Maarel, S M; van Engelen, B G M; Heijdra, Y F; Padberg, G W
2017-06-01
To test the hypothesis that wheelchair dependency and (kypho-)scoliosis are risk factors for developing respiratory insufficiency in facioscapulohumeral muscular dystrophy, we examined 81 patients with facioscapulohumeral muscular dystrophy 1 of varying degrees of severity ranging from ambulatory patients to wheelchair-bound patients. We examined the patients neurologically and by conducting pulmonary function tests: Forced Vital Capacity, Forced Expiratory Volume in 1 second, and static maximal inspiratory and expiratory mouth pressures. We did not find pulmonary function test abnormalities in ambulant facioscapulohumeral muscular dystrophy patients. Even though none of the patients complained of respiratory dysfunction, mild to severe respiratory insufficiency was found in more than one third of the wheelchair-dependent patients. Maximal inspiratory pressures and maximal expiratory pressures were decreased in most patients, with a trend that maximal expiratory pressures were more affected than maximal inspiratory pressures. Wheelchair-dependent patients with (kypho-)scoliosis showed the most restricted lung function. Wheelchair-dependent patients with (kypho-)scoliosis are at risk for developing respiratory function impairment. We advise examining this group of facioscapulohumeral muscular dystrophy patients periodically, even in the absence of symptoms of respiratory insufficiency, given its frequency and impact on daily life and the therapeutic consequences. Copyright © 2017 Elsevier B.V. All rights reserved.
INDOOR ENVIRONMENTAL DETERMINANTS OF LUNG FUNCTION IN CHILDREN
Using pulmonary function and family respiratory questionnaire data for 16,689 white children 6 to 13 yr of age from 7 geographic areas, the investigators examined the effect of several environmental and other factors on performance in a standard test of breathing. As expected, FE...
Akazawa, Tsutomu; Sakuma, Tsuyoshi; Nagaya, Shigeyuki; Sonoda, Masaru; Tanaka, Yuji; Katogi, Takehide; Nemoto, Tetsuharu; Minami, Shohei
2015-01-01
Objective To investigate the effectiveness of incentive spirometry on respiratory motion in healthy subjects using cine breathing magnetic resonance imaging (MRI). Methods Ten non-smoking healthy subjects without any history of respiratory disease were studied. Subjects were asked to perform pulmonary training using incentive spirometry every day for two weeks. To assess the effectiveness of this training, pulmonary function tests and cine breathing MRI were performed before starting pulmonary training and two weeks after its completion. Results After training, there were significant improvements in vital capacity (VC) from 3.58±0.8 L to 3.74±0.8 L and in %VC from 107.4±10.8 to 112.1±8.2. Significant changes were observed in the right diaphragm motion, right chest wall motion, and left chest wall motion, which were increased from 55.7±9.6 mm to 63.4±10.2 mm, from 15.6±6.1 mm to 23.4±10.4 mm, and from 16.3±7.6 mm to 22.0±9.8 mm, respectively. Conclusion Two weeks of training using incentive spirometry provided improvements in pulmonary function and respiratory motion, which suggested that incentive spirometry may be a useful preoperative modality for improving pulmonary function during the perioperative period. PMID:26161341
Koubaa, Abdessalem; Triki, Moez; Trabelsi, Hajer; Masmoudi, Liwa; Zeghal, Khaled N; Sahnoun, Zouhair; Hakim, Ahmed
2015-01-01
Introduction Pulmonary function is compromised in most smokers. Yet it is unknown whether exercise training improves pulmonary function and aerobic capacity in cigarette and hookah smokers and whether these smokers respond in a similar way as do non-smokers. Aim To evaluate the effects of an interval exercise training program on pulmonary function and aerobic capacity in cigarette and hookah smokers. Methods Twelve cigarette smokers, 10 hookah smokers, and 11 non-smokers participated in our exercise program. All subjects performed 30 min of interval exercise (2 min of work followed by 1 min of rest) three times a week for 12 weeks at an intensity estimated at 70% of the subject's maximum aerobic capacity ([Formula: see text]). Pulmonary function was measured using spirometry, and maximum aerobic capacity was assessed by maximal exercise testing on a treadmill before the beginning and at the end of the exercise training program. Results As expected, prior to the exercise intervention, the cigarette and hookah smokers had significantly lower pulmonary function than the non-smokers. The 12-week exercise training program did not significantly affect lung function as assessed by spirometry in the non-smoker group. However, it significantly increased both forced expiratory volume in 1 second and peak expiratory flow (PEF) in the cigarette smoker group, and PEF in the hookah smoker group. Our training program had its most notable impact on the cardiopulmonary system of smokers. In the non-smoker and cigarette smoker groups, the training program significantly improved [Formula: see text] (4.4 and 4.7%, respectively), v [Formula: see text] (6.7 and 5.6%, respectively), and the recovery index (7.9 and 10.5%, respectively). Conclusions After 12 weeks of interval training program, the increase of [Formula: see text] and the decrease of recovery index and resting heart rate in the smoking subjects indicated better exercise tolerance. Although the intermittent training program altered pulmonary function only partially, both aerobic capacity and life quality were improved. Intermittent training should be advised in the clinical setting for subjects with adverse health behaviors.
Koubaa, Abdessalem; Triki, Moez; Trabelsi, Hajer; Masmoudi, Liwa; Zeghal, Khaled N; Sahnoun, Zouhair; Hakim, Ahmed
2015-01-01
Pulmonary function is compromised in most smokers. Yet it is unknown whether exercise training improves pulmonary function and aerobic capacity in cigarette and hookah smokers and whether these smokers respond in a similar way as do non-smokers. To evaluate the effects of an interval exercise training program on pulmonary function and aerobic capacity in cigarette and hookah smokers. Twelve cigarette smokers, 10 hookah smokers, and 11 non-smokers participated in our exercise program. All subjects performed 30 min of interval exercise (2 min of work followed by 1 min of rest) three times a week for 12 weeks at an intensity estimated at 70% of the subject's maximum aerobic capacity (VO2max). Pulmonary function was measured using spirometry, and maximum aerobic capacity was assessed by maximal exercise testing on a treadmill before the beginning and at the end of the exercise training program. As expected, prior to the exercise intervention, the cigarette and hookah smokers had significantly lower pulmonary function than the non-smokers. The 12-week exercise training program did not significantly affect lung function as assessed by spirometry in the non-smoker group. However, it significantly increased both forced expiratory volume in 1 second and peak expiratory flow (PEF) in the cigarette smoker group, and PEF in the hookah smoker group. Our training program had its most notable impact on the cardiopulmonary system of smokers. In the non-smoker and cigarette smoker groups, the training program significantly improved VO2max (4.4 and 4.7%, respectively), v VO2max (6.7 and 5.6%, respectively), and the recovery index (7.9 and 10.5%, respectively). After 12 weeks of interval training program, the increase of VO2max and the decrease of recovery index and resting heart rate in the smoking subjects indicated better exercise tolerance. Although the intermittent training program altered pulmonary function only partially, both aerobic capacity and life quality were improved. Intermittent training should be advised in the clinical setting for subjects with adverse health behaviors.
Pulmonary function in microgravity: Spacelab 4 and beyond
NASA Technical Reports Server (NTRS)
Guy, H. J.; Prisk, G. K.; West, J. B.
1988-01-01
This paper refers principally to the composition gradient of gases within the lung in various conditions of gravity, as revealed by exhaled breath. A rapid gas analyzer-based system has been developed for tests in Spacelab 4. The test sequence and expected results are presented.
[Recurrent pulmonary infection and oral mucosal ulcer].
Kuang, Fei-Mei; Tang, Lan-Lan; Zhang, Hui; Xie, Min; Yang, Ming-Hua; Yang, Liang-Chun; Yu, Yan; Cao, Li-Zhi
2017-04-01
An 8-year-old girl who had experienced intermittent cough and fever over a 3 year period, was admitted after experiencing a recurrence for one month. One year ago the patient experienced a recurrent oral mucosal ulcer. Physical examination showed vitiligo in the skin of the upper right back. Routine blood tests and immune function tests performed in other hospitals had shown normal results. Multiple lung CT scans showed pulmonary infection. The patient had recurrent fever and cough and persistent presence of some lesions after anti-infective therapy. The antitubercular therapy was ineffective. Routine blood tests after admission showed agranulocytosis. Gene detection was performed and she was diagnosed with dyskeratosis congenita caused by homozygous mutation in RTEL1. Patients with dyskeratosis congenita with RTEL1 gene mutation tend to develop pulmonary complications. Since RTEL1 gene sequence is highly variable with many mutation sites and patterns and can be inherited via autosomal dominant or recessive inheritance, this disease often has various clinical manifestations, which may lead to missed diagnosis or misdiagnosis. For children with unexplained recurrent pulmonary infection, examinations of the oral cavity, skin, and nails and toes should be taken and routine blood tests should be performed to exclude dyskeratosis congenita. There are no specific therapies for dyskeratosis congenita at present, and when bone marrow failure and pulmonary failure occur, hematopoietic stem cell transplantation and lung transplantation are the only therapies. Androgen and its derivatives are effective in some patients. Drugs targeting the telomere may be promising for patients with dyskeratosis congenita.
Pulmonary function parameters and use of bronchodilators in patients with cystic fibrosis*
Muramatu, Lucia Harumi; Stirbulov, Roberto; Forte, Wilma Carvalho Neves
2013-01-01
OBJECTIVE: To analyze pulmonary function parameters and pharmacodynamic response to a bronchodilator, as well as the prescription of bronchodilators, in cystic fibrosis (CF) patients. METHODS: This was a retrospective cohort study involving patients 6-18 years of age, diagnosed with CF, and followed at a referral center between 2008 and 2010. We evaluated only those patients who were able to perform pulmonary function tests (PFTs). We analyzed FVC, FEV1, and FEF25-75%, expressed as percentages of the predicted values, prior to and after bronchodilator tests (pre-BD and post-BD, respectively), in 312 PFTs. Repeated measures ANOVA and multiple comparisons were used. RESULTS: The study included 56 patients, divided into two groups: those whose PFT results spanned the 2008-2010 period (n = 37); and those whose PFT results spanned only the 2009-2010 period (n = 19). In the 2008-2010 group, there were significant reductions in post-BD FEV1 between 2008 and 2010 (p = 0.028) and between 2009 and 2010 (p = 0.036), as was also the case for pre-BD and post-BD FEF25 75% in all multiple comparisons (2008 vs. 2009; 2008 vs. 2010; and 2009 vs. 2010). In the 2009-2010 group, there were no significant differences between any of the years for any of the variables studied. Among the 312 PFTs, significant responses to the bronchodilator occurred in only 24 (7.7%), all of which were from patients for whom no bronchodilator had been prescribed during the study period. CONCLUSIONS: In the CF patients studied, there was loss of pulmonary function, indicating progressive lung disease, over time. The changes were greater for FEF25-75% than for the other variables, which suggests the initial involvement of small airways. PMID:23503485
Daga, Mradul Kumar; Khan, Naushad Ahmad; Malhotra, Varun; Kumar, Suman; Mawari, Govind; Hira, Harmanjit Singh
2014-04-01
Chronic obstructive pulmonary disease (COPD) is characterized by irreversible airflow limitation and is associated with weight loss and decreased muscle strength and exercise capacity. A double-blinded randomized controlled trial of 32 male COPD patients (age, 54.94 ± 11.27 years) was carried out to assess effects of anabolic steroid in terms of a daily high-protein, high-calorie diet alone or one combined with anabolic steroids on body composition, lung function, and health-related quality of life (HRQL). Outcomes were assessed by anthropometric and spirometric measurements, peak expiratory flow rate, partial pressure of oxygen in arterial blood, 6-minute walk test (6MWT), hand grip test, and HRQL index scores. Measurements were made at baseline and end of treatment (6 weeks). All patients showed significant difference (P < .001) in pulmonary function parameters and anthropometric measurements after 6 weeks of intervention (within-group changes); however, no significant improvement occurred in the pulmonary function parameters between the groups. The difference in exercise capacity (6MWT) and HRQL scores in the treatment group were statistically significant (P < .001) compared with control group after 6 weeks of intervention. In the treatment group, the average 6MWT distance increased from 213.5 m to 268.5 m at 6-week follow-up, and HRQL scores increased from 101.25 to 118.45. Also, HRQL and 6MWT parameters were positively correlated in response to steroid supplementation at the end of the study. Weekly administration of anabolic steroids during 6 weeks increased exercise capacity and quality of life in patients with COPD.
Cardiopulmonary Exercise Testing in Adult Congenital Heart Disease.
Mantegazza, Valentina; Apostolo, Anna; Hager, Alfred
2017-07-01
Recently, the number of patients with congenital heart diseases reaching adulthood has been progressively increasing in developed countries, and new issues are emerging: the evaluation of their capacity to cope with physical activity and whether this knowledge can be used to optimize medical management. A symptom-limited cardiopulmonary exercise test has proven to be an essential tool, because it can objectively evaluate the functional cardiovascular capacity of these patients, identify the pathological mechanisms of the defect (circulatory failure, shunts, and/or pulmonary hypertension), and help prescribe an individualized rehabilitation program when needed. The common findings on cardiopulmonary exercise testing in patients with congenital heart diseases are a reduced peak [Formula: see text]o 2 , an early anaerobic threshold, a blunted heart rate response, a reduced increase of Vt, and an increased [Formula: see text]e/[Formula: see text]co 2 . All these measures suggest common pathophysiological abnormalities: (1) a compromised exercise capacity from anomalies affecting the heart, vessels, lungs, or muscles; (2) chronotropic incompetence secondary to cardiac autonomic dysfunction or β-blockers and antiarrhythmic therapy; and (3) ventilatory inefficiency caused by left-heart failure with pulmonary congestion, pulmonary hypertension, pulmonary obstructive vascular disease, or cachexia. Most of these variables also have prognostic significance. For these patients, cardiopulmonary exercise testing allows evaluation and decisions affecting lifestyle and therapeutic interventions.
38 CFR 4.96 - Special provisions regarding evaluation of respiratory conditions.
Code of Federal Regulations, 2012 CFR
2012-07-01
...-6845. (1) Pulmonary function tests (PFT's) are required to evaluate these conditions except: (i) When the results of a maximum exercise capacity test are of record and are 20 ml/kg/min or less. If a maximum exercise capacity test is not of record, evaluate based on alternative criteria. (ii) When...
Huber, Christoph H; Marty, Bettina; von Segesser, Ludwig K
2007-08-01
Valved stents are new land for cardiac surgeons even though they are being used more frequently by interventional disciplines. This paper presents simple steps to build a patient-specific pulmonary valved stent and its delivery device. The design concept was tested by random participants at a med-tech meeting. The valved stent is constructed by linking an endoprosthetic graft with a valved-jugular-vein. The delivery device is made from a modified 5-ml syringe. Of 72 participants, 66 (92%) built and 60 participants implanted the device successfully into the targeted pulmonary position via a trans-infundibular access.
Kuppusamy, Maheshkumar; Dilara, K; Ravishankar, P; Julius, A
2017-01-01
Prāṇāyāma , the fourth limb of ancient aṣṭāṅga yoga consists of breathing techniques which produce various physiological and psychological effects. Though various types of prāṇāyāma and their effects have been scientifically established, Bhrāmarī prāṇāyāma (Bhr.P) is the one whose effects still remain understated. The present study was conducted to find the effects of Bhrāmarī prāṇāyāma practice on pulmonary function in healthy adolescents. Randomized control trial. 90 healthy adolescents including 32 females and 58 males participated in the study. They were randomly divided into Bhr.P group ( n = 45) and Control group ( n = 45) by a simple lottery method. Pulmonary function test was done at baseline and at end of 12 th week using RMS Helios spirometry. Prāṇāyāma group students were trained to do Bhr.P as 3 to 4 breaths/min for 5 min followed by 2 min rest. This was one cycle and in this way, they were instructed to do five cycles each time for 45 minutes five days in a week. Control group students were not allowed to practice any kind of exercise throughout the study period. Student paired and unpaired T tests were used to analyse the intra group and intergroup differences using R statistical software. A significant ( P < 0.05) improvement in all pulmonary function parameters; FVC, FEV1, FEV1/FVC ratio, FEF 25%-75% and PEFR was seen in the Bhr.P group than the control group adolescents. Slow vital capacity (SVC) and Maximum Voluntary Volume (MVV) also showed significant improvement in the prāṇāyāma group. Bhrāmarī Prāṇāyāma practice is effective in improving the pulmonary function among the adolescents which could be utilized for further clinical studies.
21 CFR 868.1840 - Diagnostic spirometer.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) Identification. A diagnostic spirometer is a device used in pulmonary function testing to measure the volume of gas moving in or out of a patient's lungs. (b) Classification. Class II (performance standards). ...
In Vitro Study of Flow Regulation for Pulmonary Insufficiency
Camp, T. A.; Stewart, K. C.; Figliola, R. S.; McQuinn, T.
2007-01-01
Given the tolerance of the right heart circulation to mild regurgitation and gradient, we study the potential of using motionless devices to regulate the pulmonary circulation. In addition, we document the flow performance of two mechanical valves. A motionless diode, a nozzle, a mechanical bileaflet valve, and a tilting disk valve were tested in a pulmonary mock circulatory system over the normal human range of pulmonary vascular resistance (PVR). For the mechanical valves, regurgitant fractions (RFs) and transvalvular pressure gradients were found to be weak functions of PVR. On the low end of normal PVR, the bileaflet and tilting disk valves fluttered and would not fully close. Despite this anomaly, the regurgitant fraction of either valve did not change significantly. The values for RF and transvalvular gradient measured varied from 4 to 7% and 4 to 7 mm Hg, respectively, at 5 lpm for all tests. The diode valve was able to regulate flow with mild regurgitant fraction and trivial gradient but with values higher than either mechanical valve tested. Regurgitant fraction ranged from 2 to 17% in tests extending from PVR values of 1 to 4.5 mm Hg/lpm at 5 lpm and with concomitant increases in gradient up to 17 mm Hg. The regurgitant fraction for the nozzle increased from 2 to 23% over the range of PVR with gradients increasing to 18 mm Hg. The significant findings were: (1) the mechanical valves controlled regurgitation at normal physiological cardiac output and PVR even though they failed to close at some normal values of PVR and showed leaflet flutter; and (2) it may be possible to regulate the pulmonary circulation to tolerable levels using a motionless pulmonary valve device. PMID:17408334
Gracia, Fernando; Armien, Blas; Simpson, Steven Q; Munoz, Carlos; Broce, Candida; Pascale, Juan Miguel; Koster, Frederick
2010-10-01
The objective of this study was to document persistent pulmonary symptoms and pulmonary function abnormalities in adults surviving hantavirus pulmonary syndrome (HPS). Acute infection by most hantaviruses result in mortality rates of 25-35%, while in Panama the mortality rate of 10% is contrasted by an unusually high incidence. In all types of HPS, the viral prodrome, cardiopulmonary phase due to massive pulmonary capillary leak syndrome, and spontaneous diuresis are followed by a convalescent phase with exertional dyspnea for 3-4 weeks, but the frequency of persistent symptoms is not known. In this observational study of a convenience sample, 14 survivors of HPS caused by Choclo virus infection in Panama and 9 survivors of HPS caused by Sin Nombre virus infection in New Mexico completed a questionnaire and pulmonary function tests up to 8 years after infection. In both groups, exertional dyspnea persisted for 1-2 years after acute infection in 43% (Panama) and 77% (New Mexico) of survivors surveyed. Reduction in midexpiratory flows (FEF(25-75%)), increased residual volume (RV), and reduced diffusion capacity (D(L)CO/VA) also were common in both populations; but the severity of reduced expiratory flow did not correlate with exertional dyspnea. Symptoms referable to previous hantavirus infection had resolved within 3 years of acute infection in most but not all patients in the Panama group. Temporary exertional dyspnea and reduced expiratory flow are common in early convalescence after HPS but resolves in almost all patients.
Valeiro, Beatriz; Hernández, Carme; Barberán-Garcia, Anael; Rodríguez, Diego A; Aibar, Jesús; Llop, Lourdes; Vilaró, Jordi
2016-05-01
The Glittre Activities of Daily Living Test (ADL-Test) is a reliable functional status measurement for stable chronic obstructive pulmonary disease (COPD) patients in a laboratory setting. We aimed to adapt the test to the home setting (mADL-Test) and to follow-up the functional status recovery of post-exacerbation COPD patients included in a home hospitalization (HH) program. We assessed 17 exacerbated moderate-to-very-severe COPD patients in 3 home visits: at discharge to HH (V0), 10days (V10post) and 1month after discharge (V30post). Patients completed the mADL-Test (laps, VO2 and VE), COPD assessment test (CAT), London Chest ADL Test (LCADL), modified Medical Research Council (mMRC) and upper limb strength (handgrip). The number of laps of the mADL-Test (4, 5 and 5, P<.05), CAT (19, 12 and 12, P<.01), mMRC (2, 1.5 and 1, P<.01) and the self-care domain of the LCADL (6, 5 and 5, P<.01) improved during follow-up (V0, V10post and V30post, respectively). No significant changes were evidenced in VO2, VE or handgrip. Our results suggest that the mADL-test can be performed in the home setting after a COPD exacerbation, and that functional status continues to improve 10days after discharge to HH. Copyright © 2015 SEPAR. Published by Elsevier Espana. All rights reserved.
Santos, Bruna F A; Souza, Hugo C D; Miranda, Aline P B; Cipriano, Federico G; Gastaldi, Ada C
2016-01-01
To assess functional capacity in the preoperative phase of pulmonary surgery by comparing predicted and obtained values for the six-minute walk test (6MWT) in patients with and without postoperative pulmonary complication (PPC) METHOD: Twenty-one patients in the preoperative phase of open thoracotomy were evaluated using the 6MWT, followed by monitoring of the postoperative evolution of each participant who underwent the routine treatment. Participants were then divided into two groups: the group with PPC and the group without PPC. The results were also compared with the predicted values using reference equations for the 6MWT RESULTS: Over half (57.14%) of patients developed PPC. The 6MWT was associated with the odds for PPC (odds ratio=22, p=0.01); the group without PPC in the postoperative period walked 422.38 (SD=72.18) meters during the 6MWT, while the group with PPC walked an average of 340.89 (SD=100.93) meters (p=0.02). The distance traveled by the group without PPC was 80% of the predicted value, whereas the group with PPC averaged less than 70% (p=0.03), with more appropriate predicted values for the reference equations The 6MWT is an easy, safe, and feasible test for routine preoperative evaluation in pulmonary surgery and may indicate patients with a higher chance of developing PPC.
A low-cost mobile adaptive tracking system for chronic pulmonary patients in home environment.
Işik, Ali Hakan; Güler, Inan; Sener, Melahat Uzel
2013-01-01
The main objective of this study is presenting a real-time mobile adaptive tracking system for patients diagnosed with diseases such as asthma or chronic obstructive pulmonary disease and application results at home. The main role of the system is to support and track chronic pulmonary patients in real time who are comfortable in their home environment. It is not intended to replace the doctor, regular treatment, and diagnosis. In this study, the Java 2 micro edition-based system is integrated with portable spirometry, smartphone, extensible markup language-based Web services, Web server, and Web pages for visualizing pulmonary function test results. The Bluetooth(®) (Bluetooth SIG, Kirkland, WA) virtual serial port protocol is used to obtain the test results from spirometry. General packet radio service, wireless local area network, or third-generation-based wireless networks are used to send the test results from a smartphone to the remote database. The system provides real-time classification of test results with the back propagation artificial neural network algorithm on a mobile smartphone. It also provides the generation of appropriate short message service-based notification and sending of all data to the Web server. In this study, the test results of 486 patients, obtained from Atatürk Chest Diseases and Thoracic Surgery Training and Research Hospital in Ankara, Turkey, are used as the training and test set in the algorithm. The algorithm has 98.7% accuracy, 97.83% specificity, 97.63% sensitivity, and 0.946 correlation values. The results show that the system is cheap (900 Euros) and reliable. The developed real-time system provides improvement in classification accuracy and facilitates tracking of chronic pulmonary patients.
Non-invasive imaging of global and regional cardiac function in pulmonary hypertension
Crowe, Tim; Jayasekera, Geeshath
2017-01-01
Pulmonary hypertension (PH) is a progressive illness characterized by elevated pulmonary artery pressure; however, the main cause of mortality in PH patients is right ventricular (RV) failure. Historically, improving the hemodynamics of pulmonary circulation was the focus of treatment; however, it is now evident that cardiac response to a given level of pulmonary hemodynamic overload is variable but plays an important role in the subsequent prognosis. Non-invasive tests of RV function to determine prognosis and response to treatment in patients with PH is essential. Although the right ventricle is the focus of attention, it is clear that cardiac interaction can cause left ventricular dysfunction, thus biventricular assessment is paramount. There is also focus on the atrial chambers in their contribution to cardiac function in PH. Furthermore, there is evidence of regional dysfunction of the two ventricles in PH, so it would be useful to understand both global and regional components of dysfunction. In order to understand global and regional cardiac function in PH, the most obvious non-invasive imaging techniques are echocardiography and cardiac magnetic resonance imaging (CMRI). Both techniques have their advantages and disadvantages. Echocardiography is widely available, relatively inexpensive, provides information regarding RV function, and can be used to estimate RV pressures. CMRI, although expensive and less accessible, is the gold standard of biventricular functional measurements. The advent of 3D echocardiography and techniques including strain analysis and stress echocardiography have improved the usefulness of echocardiography while new CMRI technology allows the measurement of strain and measuring cardiac function during stress including exercise. In this review, we have analyzed the advantages and disadvantages of the two techniques and discuss pre-existing and novel forms of analysis where echocardiography and CMRI can be used to examine atrial, ventricular, and interventricular function in patients with PH at rest and under stress. PMID:29064323
Ghani, Nadia; Khalid, Anum; Tahir, Arifa
2016-07-01
To examine the effects of airborne endotoxin on lung function impairment in exposure-response relationships among the workers of textile industry. The cross-sectional study was conducted at Lahore College for Women University, Lahore, Pakistan, from January to August 2014, and comprised textile mill workers. The participants were divided into exposed and control groups. A questionnaire was used to ask workers about the potential adverse health effects of their occupation. The pulmonary function test was carried out by spirometer. Endotoxin levels in the samples were determined using the key quality characteristics limulus amebocyte lysate. The data was analysed to determine the correlation between the endotoxin exposure duration and pulmonary function test parameters. There were 200 subjects subdivided into 100 each inexposed and control groups. Overall, 160(80%) were not aware of safety measures and the remaining 40(20%) were partially practising. Changes in pulmonary function due to endotoxin exposure showed decreased force vital capacity, flow rate and peak expiratory flow parameters significantly different (p<0.05, p<0.001). The endotoxin concentration was between 12EU/m3 and 300EU/m3. Airborne endotoxin concentrations in textile plants exceeded the Dutch health-based guidance limit of 90EU/m3 and was associated with respiratory health effects. Prolonged exposure to airborne endotoxin caused constant lung impairment. Proper safety measures should be adopted to avoid the inhalation of cotton dust.
Lin, Shuan-Pei; Shih, Shou-Chuan; Chuang, Chih-Kuang; Lee, Kuo-Sheng; Chen, Ming-Ren; Niu, Dau-Ming; Chiu, Pao Chin; Lin, Shio Jean; Lin, Hsiang-Yu
2014-03-01
The mucopolysaccharidoses (MPS) comprise a group of inherited lysosomal storage disorders characterized by deficiencies in enzymes catalyzing the degradation of glycosaminoglycans. Impairment of pulmonary function is an important health problem for patients with MPS. However, there are few published reports on the prevalence and severity of pulmonary dysfunction in relation to age and treatment in this disorder. To evaluate pulmonary function in patients with MPS, we performed spirometry in 35 patients (22 males and 13 females; 1 with MPS I, 12 with MPS II, 16 with MPS IVA, and 6 with MPS VI; mean age, 14.6 ± 5.9 years; age range, 6.4 years to 33 years). Forced vital capacity (FVC), forced expired volume in 1 sec (FEV1), FEV1 to FVC ratio (FEV1/FVC), peak expiratory flow (PEF), and mean forced expiratory flow during the middle half of FVC (FEF25-75% ) were measured. Mean FVC, FEV1 , PEF, and FEF25-75% were 74.2%, 73.9%, 64.7%, and 37.1% of the predicted values, respectively. By spirometric classification, 32 patients (91%) had small airway disease (FEF25-75% < 65%), 17 (48%) had restrictive lung disease, and 3 (9%) had obstructive lung disease. Percent predicted FVC, FEV1 , and PEF, as well as FEV1 /FVC, were all negatively correlated with age (P < 0.01), such that pubertal and post-pubertal patients had significantly lower values than younger patients. Of eight attenuated MPS II and VI patients who underwent follow-up pulmonary function testing after receiving enzyme replacement therapy (ERT) for 1.5-7.4 years, six showed improvements in % predicted FVC and five improved in % predicted FEV1 . Our additional characterization of the types and prevalence of pulmonary function abnormalities seen in MPS patients should be useful for clinical care. © 2013 Wiley Periodicals, Inc.
Cardio-pulmonary fitness test by ultra-short heart rate variability.
Aslani, Arsalan; Aslani, Amir; Kheirkhah, Jalal; Sobhani, Vahid
2011-10-01
It is known that exercise induces cardio-respiratory autonomic modulation. The aim of this study was to assess the cardio-pulmonary fitness by ultra-short heart rate variability. Study population was divided into 3 groups: Group-1 (n = 40) consisted of military sports man. Group-2 (n = 40) were healthy age-matched sedentary male subjects with normal body mass index [BMI = 19 - 25 kg/m(2)). Group-3 (n = 40) were healthy age-matched obese male subjects [BMI > 29 kg/m(2)). Standard deviation of normal-to-normal QRS intervals (SDNN) was recorded over 15 minutes. Bruce protocol treadmill test was used; and, maximum oxygen consumption (VO(2)max) was calculated. WHEN THE STUDY POPULATION WAS DIVIDED INTO QUARTILES OF SDNN (FIRST QUARTILE: < 60 msec; second quartile: > 60 and < 100 msec; third quartile: > 100 and <140 msec; and fourth quartile: >140 msec), progressive increase was found in VO(2)max; and, SDNN was significantly linked with estimated VO(2)max. In conclusion, the results of this study demonstrate that exercise training improves cardio-respiratory autonomic function (and increases heart rate variability). Improvement in cardio-respiratory autonomic function seems to translate into a lower rate of long term mortality. Ultra-short heart rate variability is a simple cardio-pulmonary fitness test which just requires 15 minutes, and involves no exercise such as in the treadmill or cycle test.
Bedzra, Edo K S; Dardas, Todd F; Cheng, Richard K; Pal, Jay D; Mahr, Claudius; Smith, Jason W; Shively, Kent; Masri, S Carolina; Levy, Wayne C; Mokadam, Nahush A
2017-12-01
To investigate the effect of pulmonary function testing on outcomes after continuous flow left ventricular assist device implantation. A total of 263 and 239 patients, respectively, had tests of forced expiratory volume in 1 second and diffusing capacity of the lungs for carbon monoxide preoperatively for left ventricular assist device implantations between July 2005 and September 2015. Kaplan-Meier analysis and multivariable Cox regressions were performed to evaluate mortality. Patients were analyzed in a single cohort and across 5 groups. Postoperative intensive care unit and hospital lengths of stay were evaluated with negative binomial regressions. There is no association of forced expiratory volume in 1 second and diffusing capacity of the lungs for carbon monoxide with survival and no difference in mortality at 1 and 3 years between the groups (log rank P = .841 and .713, respectively). Greater values in either parameter were associated with decreased hospital lengths of stay. Only diffusing capacity of the lungs for carbon monoxide was associated with increased intensive care unit length of stay in the group analysis (P = .001). Ventilator times, postoperative pneumonia, reintubation, and tracheostomy rates were similar across the groups. Forced expiratory volume in 1 second and diffusing capacity of the lungs for carbon monoxide are not associated with operative or long-term mortality in patients undergoing continuous flow left ventricular assist device implantation. These findings suggest that these abnormal pulmonary function tests alone should not preclude mechanical circulatory support candidacy. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Pugh, Meredith E.; Newman, Alexander L.; Robbins, Ivan M.; Tolle, James; Austin, Eric D.; Newman, John H.
2011-01-01
Background: CO2 excretion is impaired in pulmonary arterial hypertension (PAH) due to underlying vascular obstruction and increased dead space. Our aim was to determine whether resting end tidal CO2 (Etco2) could differentiate patients with PAH from those with pulmonary venous hypertension (PVH) or patients without pulmonary hypertension (PH) and whether successful treatment of PAH resulted in higher Etco2 values. Methods: We performed Etco2 measurements for five breaths at rest and after a 6-min walk test (6MWT) in patients seen at our pulmonary vascular center. Mean Etco2 values were correlated with 6-min walk distance and right-sided heart catheterization data. Results: We enrolled 84 patients with PAH, 17 with PVH without left ventricular systolic dysfunction, and seven with no PH and no severe alterations in pulmonary function testing. Etco2 was significantly lower in patients with PAH than in those with no PH and PVH (P < .0001 PAH vs both groups). Etco2 correlated with the pulmonary artery diastolic pressure-to-pulmonary artery occlusion pressure gradient (r = −0.50, P = .0002) and pulmonary vascular resistance (r = −0.44, P = .002). Etco2 after 6MWT correlated with walk distance (r = 0.34, P = .003). In patients with prostaglandin therapy escalation, Etco2 increased in those who had clinical improvement, whereas in patients who did not improve clinically, Etco2 failed to rise (P = .04). Conclusions: Etco2 is a promising tool to differentiate patients with PAH from those with PVH or no PH, correlates with diagnostic and prognostic hemodynamic indicators, and may increase with successful treatment of PAH. PMID:21622547
Effect of lung volume reduction surgery on resting pulmonary hemodynamics in severe emphysema.
Criner, Gerard J; Scharf, Steven M; Falk, Jeremy A; Gaughan, John P; Sternberg, Alice L; Patel, Namrata B; Fessler, Henry E; Minai, Omar A; Fishman, Alfred P
2007-08-01
To determine the effect of medical treatment versus lung volume reduction surgery (LVRS) on pulmonary hemodynamics. Three clinical centers of the National Emphysema Treatment Trial (NETT) screened patients for additional inclusion into a cardiovascular (CV) substudy. Demographics were determined, and lung function testing, six-minute-walk distance, and maximum cardiopulmonary exercise testing were done at baseline and 6 months after medical therapy or LVRS. CV substudy patients underwent right heart catheterization at rest prerandomization (baseline) and 6 months after treatment. A total of 110 of the 163 patients evaluated for the CV substudy were randomized in NETT (53 were ineligible), 54 to medical treatment and 56 to LVRS. Fifty-five of these patients had both baseline and repeat right heart catheterization 6 months postrandomization. Baseline demographics and lung function data revealed CV substudy patients to be similar to the remaining 1,163 randomized NETT patients in terms of age, sex, FEV(1), residual volume, diffusion capacity of carbon monoxide, Pa(O(2)), Pa(CO(2)), and six-minute-walk distance. CV substudy patients had moderate pulmonary hypertension at rest (Ppa, 24.8 +/- 4.9 mm Hg); baseline hemodynamic measurements were similar across groups. Changes from baseline pressures to 6 months post-treatment were similar across treatment groups, except for a smaller change in pulmonary capillary wedge pressure at end-expiration post-LVRS compared with medical treatment (-1.8 vs. 3.5 mm Hg, p = 0.04). In comparison to medical therapy, LVRS was not associated with an increase in pulmonary artery pressures.
Enhanced response to ozone exposure during the follicular phase of the menstrual cycle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fox, S.D.; Adams, W.C.; Brookes, K.A.
Exposure to ozone (O[sub 3]), a toxic component of photochemical smog, results in significant airway inflammation, respiratory discomfort, and pulmonary function impairment. These effects can be reduced via pretreatment with anti-inflammatory agents. Progesterone, a gonadal steroid, is known to reduce general inflammation in the uterine endometrium. However, it is not known whether fluctuation in blood levels of progesterone, which are experienced during the normal female menstrual cycle, could alter O[sub 3] inflammatory-induced pulmonary responses. In this study, we tested the hypothesis that young, adult females are more responsive to O[sub 3] inhalation with respect to pulmonary function impairment during theirmore » follicular (F) menstrual phase when progesterone levels are lowest that during their mid-luteal (ML) phase when progesterone levels are highest. Nine subjects with normal ovarian function were exposed in random order for 1 hour each to filtered air and to 0.30 ppm O[sub 3] in their F and ML menstrual phases. Ozone responsiveness was measured by percent change in pulmonary function from pre- to postexposure. Significant gas concentration effects (filtered air versus O[sub 3]) were observed for forced vital capacity (FVC), forced expiratory volume in 1 sec (FEV[sub 1]), and forced expiratory flow between 25 and 75% of FVC (FEF[sub 25-75]), showed a significant menstrual phase and gas concentration interaction effect, with larger decrements observed in the F menstrual phase when progesterone concentrations were significantly lower. We conclude that young, adult females appear to be more responsive to acute O[sub 3] exposure during the F phase than during the ML phase of their menstrual cycles. This difference in pulmonary function response could be related to the anti-inflammatory effects of increased progesterone concentrations during the luteal phase.« less
Pulmonary function improvement after vertebral column resection for severe spinal deformity.
Bumpass, David B; Lenke, Lawrence G; Bridwell, Keith H; Stallbaumer, Jeremy J; Kim, Yongjung J; Wallendorf, Michael J; Min, Woo-Kie; Sides, Brenda A
2014-04-01
Retrospective review of prospectively accrued cohorts. We hypothesized that posterior-only vertebral column resection (PVCR) would result in improved postoperative pulmonary function, avoiding pulmonary insults from combined anterior/posterior approaches. Pulmonary function after PVCR for severe spinal deformity has not been previously studied. Previous studies have demonstrated impaired pulmonary performance after combined anterior/posterior fusions. Serial pulmonary function testing (PFTs) in 49 patients (27 pediatric, 22 adult) who underwent PVCR at a single institution was reviewed. Mean age at surgery was 28.7 years (range, 8-74 yr), and mean follow-up was 32 months (range, 23-64 mo). Thoracic PVCRs (T5-T11) were performed in 31 patients and thoracolumbar PVCRs (T12-L5) in 18 patients. Pediatric patients who underwent PVCR experienced both increased mean forced vital capacity (FVC) (2.10-2.43 L, P = 0.0005) and forced expiratory volume in 1 second (FEV1) (1.71-1.98 L, P = 0.001). There were no significant differences in percent-predicted values for FVC (69%-66%, P = 0.51) or FEV1 (64%-63%, P = 0.77). In adult patients, there were no significant changes in FVC (2.73-2.61 L, P = 0.35) or FEV1 (2.22-2.07 L, P = 0.51) after PVCR; also, changes in adult percent-predicted values for FVC (79%-76%, P = 0.47) and FEV1 (78%-74%, P = 0.40) were not significant. In pediatric patients who underwent PVCR, improved PFTs were correlated with younger age (P = 0.02), diagnosis of angular kyphosis (P ≤ 0.0001), no previous spine surgery (P = 0.04), and preoperative halo-gravity traction (P = 0.02). Comparison of PFT changes between patients who underwent PVCR and a control group who underwent combined anterior/posterior approaches revealed no significant differences. In pediatric patients, PVCR resulted in small but significant improvements in postoperative FVC and FEV1. In adult patients, no significant increases in PFTs were found. Patients who have the greatest potential for lung and thoracic cage growth after spinal correction are most likely to have improved pulmonary function after PVCR.
Ito, Tomoki; Ozaki, Yoshio; Son, Yonsu; Nishizawa, Tohru; Amuro, Hideki; Tanaka, Akihiro; Tamaki, Takeshi; Nomura, Shosaku
2014-07-11
Pulmonary arterial hypertension is a fatal disease characterized by progressive remodeling of the pulmonary arteries and an increase in pulmonary vascular resistance. Up to 50% of patients with systemic sclerosis have pulmonary arterial hypertension, which significantly affects the prognosis. The endothelin receptor antagonist bosentan is used for the treatment of pulmonary arterial hypertension and shows a great beneficial effect. However, the most frequent side effect of bosentan is liver toxicity, which often requires dose reduction and discontinuation. We report two cases (a 64-year-old Japanese woman and a 69-year old Japanese woman) of systemic sclerosis, both with severe Raynaud's phenomenon and pulmonary arterial hypertension. Both patients had initially received bosentan monotherapy, which caused liver toxicity as indicated by increased levels of alanine aminotransferase, alkaline phosphatase, and gamma-glutamyltransferase. After dose reduction or discontinuation of bosentan, these liver function abnormalities were normalized and the patients subsequently received retreatment with a combination of bosentan and ursodeoxycholic acid. The results of liver function tests did not show any abnormalities after this combination therapy. These reports suggest the usefulness of ursodeoxycholic acid for preventing liver toxicity caused by bosentan. Thus, the addition of ursodeoxycholic acid to the treatment protocol is expected to be useful when liver toxicity emerges as a side effect of bosentan.
Haemodynamics, dyspnoea, and pulmonary reserve in heart failure with preserved ejection fraction.
Obokata, Masaru; Olson, Thomas P; Reddy, Yogesh N V; Melenovsky, Vojtech; Kane, Garvan C; Borlaug, Barry A
2018-05-19
Increases in left ventricular filling pressure are a fundamental haemodynamic abnormality in heart failure with preserved ejection fraction (HFpEF). However, very little is known regarding how elevated filling pressures cause pulmonary abnormalities or symptoms of dyspnoea. We sought to determine the relationships between simultaneously measured central haemodynamics, symptoms, and lung ventilatory and gas exchange abnormalities during exercise in HFpEF. Subjects with invasively-proven HFpEF (n = 50) and non-cardiac causes of dyspnoea (controls, n = 24) underwent cardiac catheterization at rest and during exercise with simultaneous expired gas analysis. During submaximal (20 W) exercise, subjects with HFpEF displayed higher pulmonary capillary wedge pressures (PCWP) and pulmonary artery pressures, higher Borg perceived dyspnoea scores, and increased ventilatory drive and respiratory rate. At peak exercise, ventilation reserve was reduced in HFpEF compared with controls, with greater dead space ventilation (higher VD/VT). Increasing exercise PCWP was directly correlated with higher perceived dyspnoea scores, lower peak exercise capacity, greater ventilatory drive, worse New York Heart Association (NYHA) functional class, and impaired pulmonary ventilation reserve. This study provides the first evidence linking altered exercise haemodynamics to pulmonary abnormalities and symptoms of dyspnoea in patients with HFpEF. Further study is required to identify the mechanisms by which haemodynamic derangements affect lung function and symptoms and to test novel therapies targeting exercise haemodynamics in HFpEF.
Soares, Ana Alice de Almeida; Barros, Camila Moraes; Santos, Cássia Giulliane Costa; Dos Santos, Maria Renata Aragão; Silva, José Rodrigo Santos; Silva Junior, Walderi Monteiro da; Simões, Silvia de Magalhães
2018-03-01
Rhinitis and asthma decrease quality of life. Few studies have assessed the performance of children with asthma or rhinitis under submaximal exercise. We evaluated maximal respiratory pressures, spirometric parameters, and ability to sustain submaximal exercise in these children before and after the 6-minute walk test (6MWT), compared to healthy children. This cross-sectional, analytical study included 89 children aged 6-12 years in outpatient follow-up: 27 healthy (H), 31 with rhinitis (R), and 31 with mild asthma under control (A). Pulmonary function parameters and maximal respiratory pressures were measured before and 5, 10, and 30 minutes after the 6MWT. Wilcoxon test was used to compare numerical numerical variables between two groups and analysis of variance or Kruskal-Wallis test for comparison among three groups. Total distance traveled in the 6MWT was similar among the three groups. Compared to pre-test values, VEF1 (Forced Expiratory Volume in 1 second), VEF0.75 (Forced Expiratory Volume in 0.75 second), and FEF25-75 (Forced Expiratory Flow 25-75% of the Forced Vital Capacity - CVF - curve) decreased significantly after the 6MWT in group A, and VEF0.75, FEF25-75, and VEF1/CVF decreased significantly in group R. Groups A and R had lower Maximum Inspiratory Pressure values than group H before and after the 6MWT at all time points assessed. The findings suggest that children with rhinitis and mild asthma present with alterations in respiratory muscle strength and pulmonary function not associated with clinical complaints, reinforcing the concept of the united airways.
Nicolini, Antonello; Mollar, Elena; Grecchi, Bruna; Landucci, Norma
2014-01-01
Results supporting the use and the effectiveness of positive expiratory, pressure devices in chronic obstructive pulmonary disease (COPD) patients are still controversial, We have tested the hypothesis that adding TPEP or IPPB to standard pharmacological therapy may provide additional clinical benefit over, pharmacological therapy only in patients with severe COPD. Fourty-five patients were randomized in three groups: a group was treated; with IPPB,a group was treated with TPEP and a group with pharmacological; therapy alone (control group). Primary outcome measures included the measurement of scale or, questionnaire concerning dyspnea (MRC scale),dyspnea,cough, and, sputum (BCSS) and quality of life (COPD assessment test) (CAT). Secondary, outcome measures were respiratory function testing,arterial blood gas,analysis,and hematological examinations. Both patients in the IPPB group and in the TPEP group showed a significant, improvement in two of three tests (MRC,CAT) compared to the control, group.However,in the group comparison analysis for, the same variables between IPPB group and TPEP group we observed a, significant improvement in the IPPB group (P≤.05 for MRC and P≤.01 for, CAT). The difference of action of the two techniques are evident in the results of, pulmonary function testing: IPPB increases FVC, FEV1, and MIP; this reflects, its capacity to increase lung volume. Also TPEP increases FVC and FEV1 (less, than IPPB), but increases MEP, while decreasing total lung capacity and, residual volume. The two techniques (IPPB and TPEP) improves significantly dyspnea; quality of; life tools and lung function in patients with severe COPD. IPPB demonstrated a greater effectiveness to improve dyspnea and quality of life tools (MRC, CAT) than TPEP. Copyright © 2013 SEPAR. Published by Elsevier Espana. All rights reserved.
Sung, Jae Hyuck; Choi, Byung-Gil; Maeng, Seung-Hee; Kim, Soo-Jin; Chung, Yong Hyun; Han, Jeong Hee; Song, Kyung Seuk; Lee, Yong Hwan; Cho, Yong Bong; Cho, Myung-Haing; Kim, Kwang Jong; Hyun, Jin Suk; Yu, Il Je
2004-12-01
Welder's pneumoconiosis has generally been determined as benign based on the absence of pulmonary function abnormalities in welders with marked radiographic abnormalities. Yet, there have also been several reports on welders with respiratory symptoms, indicating lung function impairment, X-ray abnormalities, and extensive fibrosis. Accordingly, this study attempted to investigate the inflammatory responses and pulmonary function changes in rats during a 60-day welding-fume-inhalation exposure period to elucidate the process of fibrosis. The rats were exposed to manual metal-arc stainless-steel welding fumes (MMA-SS) with total suspended particulate concentrations of 64.8 +/- 0.9 (low dose) and 107.8 +/- 2.6 mg/m3 (high dose) for 2 h per day in an inhalation chamber for 60 days. Animals were sacrificed after the initial 2-h exposure and after 15, 30, and 60 days, and the pulmonary function was also measured every week after the daily exposure. Elevated cellular differential counts were also measured in the acellular bronchoalveolar lavage fluid of the rats exposed to the MMA-SS fumes for 60 days. Among the pulmonary function test parameters, only the tidal volume showed a statistically significant and dose-dependent decrease after 35 to 60 days of MMA-SS welding-fume exposure. When the rats exposed to the welding fumes were left for 60 days to recover their lung function and cellular differentiation, recovery was observed in both the high and low-dose rats exposed up to 30 days, resulting in the disappearance of inflammatory cells and restoration of the tidal volume. The rats exposed for 60 days at the low dose also recovered from the inflammation and tidal volume loss, yet the rats exposed for 60 days at the high dose did not fully recover even after a 60-day recovery period. Therefore, when taken together, the results of the current study suggest that a decrease in the tidal volume could be used as an early indicator of pulmonary fibrosis induced by welding-fume exposure in Sprague Dawley rats, and fibrosis would seem to be preventable if the exposure is short-term and moderate.
Pulmonary function in microgravity
NASA Technical Reports Server (NTRS)
Guy, H. J.; Prisk, G. K.; West, J. B.
1992-01-01
We report the successful collection of a large quantity of human resting pulmonary function data on the SLS-1 mission. Preliminary analysis suggests that cardiac stroke volumes are high on orbit, and that an adaptive reduction takes at least several days, and in fact may still be in progress after 9 days on orbit. It also suggests that pulmonary capillary blood volumes are high, and remain high on orbit, but that the pulmonary interstitium is not significantly impacted. The data further suggest that the known large gravitational gradients of lung function have only a modest influence on single breath tests such as the SBN washout. They account for only approximately 25% of the phase III slope of nitrogen, on vital capacity SBN washouts. These gradients are only a moderate source of the cardiogenic oscillations seen in argon (bolus gas) and nitrogen (resident gas), on such tests. They may have a greater role in generating the normal CO2 oscillations, as here the phase relationship to argon and nitrogen reverses in microgravity, at least at mid exhalation in those subjects studied to date. Microgravity may become a useful tool in establishing the nature of the non-gravitational mechanisms that can now be seen to play such a large part in the generation of intra-breath gradients and oscillations of expired gas concentration. Analysis of microgravity multibreath nitrogen washouts, single breath washouts from more physiological pre-inspiratory volumes, both using our existing SLS-1 data, and data from the upcoming D-2 and SLS-2 missions, should be very fruitful in this regard.(ABSTRACT TRUNCATED AT 250 WORDS).
Li, F; Sun, Z; Li, H; Yang, T; Shi, Z
2018-04-01
Chronic obstructive pulmonary disease (COPD) is a leading cause of hospital admissions, which can result in a significant financial burden. To determine hospitalisation costs and factors associated with higher costs in patients with acute exacerbations of COPD (AE-COPD). Patients hospitalised for a whole year formed the study cohort. Demographic features, clinical data and hospitalisation bills were evaluated retrospectively. Student's t-test or the Mann-Whitney U-test were used to compare the mean values of variables between high-cost and low-cost groups. Logistic regression analysis was used to study the relationship between hospitalisation costs with clinical factors. A total of 188 patients were evaluated. The mean length of stay in hospital (LOSH) was 8.5 days. The mean cost of AE-COPD was US$1722.0. Costs were significantly associated with LOSH and the per cent predicted value of forced expiratory volume in one second. Age, sex, smoking index, partial oxygen pressure, partial carbon dioxide pressure, haemoglobin concentration and white blood cell counts were not associated with hospitalisation costs. Medications and laboratory services are the main drivers of hospitalisation costs in AE-COPD. Longer LOSH and reduced pulmonary function determine the high costs in hospitalised patients with AE-COPD admitted to a general ward. To reduce hospitalisation costs, more emphasis should be placed on shortening LOSH and preventing the worsening of pulmonary function.
Ginseng improves pulmonary functions and exercise capacity in patients with COPD.
Gross, D; Shenkman, Z; Bleiberg, B; Dayan, M; Gittelson, M; Efrat, R
2002-01-01
Ginseng is a root that has been used to treat patients with various illnesses for the last 2000 years. The purpose of this study was to evaluate the effects of Ginseng extract (G115) on Pulmonary Function Tests (PFTs), Maximum Voluntary Ventilation (MVV), Maximum Inspiratory Pressure (MIP) and Maximal Oxygen Consumption (VO2max) in patients with moderately-severe Chronic Obstructive Pulmonary Disease (COPD). Ninety-two adults were randomly divided into the experimental (n = 49, G115 100 mg bid for three months) and placebo-control (n = 43) groups. PFTs, MVV and MIP were studied before treatment and every two weeks for the 3-month-study period. Exercise test and VO2max measurements were performed before the beginning and after six weeks and three months. P lower than 0.05 was considered significant. Baseline demographics and pulmonary parameters were similar between the groups. In the experimental, but not in the control group, all parameters significantly increased above baseline and compared with the placebo group. Maximum increase, compared with baseline was FVC-32.5%, FEV1.0-27.0%, PEF-27.5%, FEF50-45.4%, FEF75-56.9%, MVV-40.4%, MIP-47.0% and VO2max-37.5%. No side effects were observed. G115 100 mg bid for three months, but not placebo, improved PFTs, MVV, MIP and VO2 max in patients with moderately-severe COPD with no side effects.
Pulmonary Vascular Complications of Liver Disease
Fritz, Jason S.; Fallon, Michael B.
2013-01-01
Hepatopulmonary syndrome and portopulmonary hypertension are two pulmonary vascular complications of liver disease. The pathophysiology underlying each disorder is distinct, but patients with either condition may be limited by dyspnea. A careful evaluation of concomitant symptoms, the physical examination, pulmonary function testing and arterial blood gas analysis, and echocardiographic, imaging, and hemodynamic studies is crucial to establishing (and distinguishing) these diagnoses. Our understanding of the pathobiology, natural history, and treatment of these disorders has advanced considerably over the past decade; however, the presence of either still increases the risk of morbidity and mortality in patients with underlying liver disease. There is no effective medical treatment for hepatopulmonary syndrome. Although liver transplantation can resolve hepatopulmonary syndrome, there appears to be worse survival even with transplantation. Liver transplantation poses a very high risk of death in those with significant portopulmonary hypertension, where targeted medical therapies may improve functional status and allow successful transplantation in a small number of select patients. PMID:23155142
Right Ventricular Hemodynamics in Patients with Pulmonary Hypertension
NASA Astrophysics Data System (ADS)
Browning, James; Fenster, Brett; Hertzberg, Jean; Schroeder, Joyce
2012-11-01
Recent advances in cardiac magnetic resonance imaging (CMR) have allowed for characterization of blood flow in the right ventricle (RV), including calculation of vorticity and circulation, and qualitative visual assessment of coherent flow patterns. In this study, we investigate qualitative and quantitative differences in right ventricular hemodynamics between subjects with pulmonary hypertension (PH) and normal controls. Fifteen (15) PH subjects and 10 age-matched controls underwent same day 3D time resolved CMR and echocardiography. Echocardiography was used to determine right ventricular diastolic function as well as pulmonary artery systolic pressure (PASP). Velocity vectors, vorticity vectors, and streamlines in the RV were visualized in Paraview and total RV Early (E) and Atrial (A) wave diastolic vorticity was quantified. Visualizations of blood flow in the RV are presented for PH and normal subjects. The hypothesis that PH subjects exhibit different RV vorticity levels than normals during diastole is tested and the relationship between RV vorticity and PASP is explored. The mechanics of RV vortex formation are discussed within the context of pulmonary arterial pressure and right ventricular diastolic function coincident with PH.
Quantification of heterogeneity in lung disease with image-based pulmonary function testing.
Stahr, Charlene S; Samarage, Chaminda R; Donnelley, Martin; Farrow, Nigel; Morgan, Kaye S; Zosky, Graeme; Boucher, Richard C; Siu, Karen K W; Mall, Marcus A; Parsons, David W; Dubsky, Stephen; Fouras, Andreas
2016-07-27
Computed tomography (CT) and spirometry are the mainstays of clinical pulmonary assessment. Spirometry is effort dependent and only provides a single global measure that is insensitive for regional disease, and as such, poor for capturing the early onset of lung disease, especially patchy disease such as cystic fibrosis lung disease. CT sensitively measures change in structure associated with advanced lung disease. However, obstructions in the peripheral airways and early onset of lung stiffening are often difficult to detect. Furthermore, CT imaging poses a radiation risk, particularly for young children, and dose reduction tends to result in reduced resolution. Here, we apply a series of lung tissue motion analyses, to achieve regional pulmonary function assessment in β-ENaC-overexpressing mice, a well-established model of lung disease. The expiratory time constants of regional airflows in the segmented airway tree were quantified as a measure of regional lung function. Our results showed marked heterogeneous lung function in β-ENaC-Tg mice compared to wild-type littermate controls; identified locations of airway obstruction, and quantified regions of bimodal airway resistance demonstrating lung compensation. These results demonstrate the applicability of regional lung function derived from lung motion as an effective alternative respiratory diagnostic tool.
76 FR 39878 - Agency Forms Undergoing Paperwork Reduction Act Review
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-07
.... Proposed Project Pulmonary Function Testing Course Approval Program, 29 CFR 1910.1043--Extension--(OMB No... Occupational Safety and Health Administration's Cotton Dust Standard, 29 CFR 1920.1043, for approving courses...
76 FR 29243 - Agency Forms Undergoing Paperwork Reduction Act Review
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-20
.... Proposed Project Pulmonary Function Testing Course Approval Program, 29 CFR 1910.1043--Extension--(OMB No... Occupational Safety and Health Administration's Cotton Dust Standard, 29 CFR 1920.1043, for approving courses...
Effects of side lying on lung function in older individuals.
Manning, F; Dean, E; Ross, J; Abboud, R T
1999-05-01
Body positioning exerts a strong effect on pulmonary function, but its effect on other components of the oxygen transport pathway are less well understood, especially the effects of side-lying positions. This study investigated the interrelationships between side-lying positions and indexes of lung function such as spirometry, alveolar diffusing capacity, and inhomogeneity of ventilation in older individuals. Nineteen nonsmoking subjects (mean age=62.8 years, SD=6.8, range=50-74) with no history of cardiac or pulmonary disease were tested over 2 sessions. The test positions were sitting and left side lying in one session and sitting and right side lying in the other session. In each of the positions, forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), single-breath pulmonary diffusing capacity (DLCO/VA), and the slope of phase III (DN2%/L) of the single-breath nitrogen washout test to determine inhomogeneity of ventilation were measured. Compared with measurements obtained in the sitting position, FVC and FEV1 were decreased equally in the side-lying positions, but no change was observed in DLCO/VA or DN2%/L. Side-lying positions resulted in decreases in FVC and FEV1, which is consistent with the well-documented effects of the supine position. These findings further support the need for prescriptive rather than routine body positioning of patients with risks of cardiopulmonary compromise and the need to use upright positions in which lung volumes and capacities are maximized.
Ataee, Pedram; Najafi, Mehri; Gharagozlou, Mohammad; Aflatounian, Majid; Mahmoudi, Maryam; Khodadad, Ahmad; Farahmand, Fatemeh; Motamed, Farzaneh; Fallahi, Glolam Hossein; Kalantari, Najmoddin; Soheili, Habib; Modarresi, Vajiheh; Modarresi, Mozhgan Sabbaghian; Rezaei, Nima
2014-01-01
Zinc deficiency, which is common in patients with cystic fibrosis (CF), can lead to several complications that may increase the number of hospital admissions in this group of patients. As supplementary zinc can prevent such complications, this study was performed to evaluate the effect of supplementary zinc on body mass index (BMI), forced expiratory volume in one second (FEV1) and number of hospitalizations in CF patients. In this study, 30 children with CF, who were referred to the Digestive Diseases Clinic of the Children's Medical Center in Tehran, were enrolled. Supplementary zinc of 2 mg/kg per day was administered to all patients. Serum level of zinc, alkaline phosphatase, and albumin as well as BMI, FEV1, and number of hospitalizations were compared before and after zinc administration. Height (p<0.001), weight (p<0.001) and BMI (p=0.001) were significantly increased after zinc, while the number of hospitalizations was significantly decreased (p=0.023). In contrast to patients with normal pulmonary function tests who received supplement therapy, BMI was not increased in those with abnormal pulmonary function after supplementary zinc. Supplementary zinc can increase BMI in CF patients, mostly in those with normal pulmonary function. While supplementary zinc may decrease the number of hospitalizations, other factors can also influence the hospitalization number.
Şaş, Senem; Toprak Çelenay, Şeyda; Özer Kaya, Derya
2016-12-20
This study aimed to evaluate the effects of balneotherapy on acute, process-related, and cumulative peripheral cardiac responses and pulmonary functions in patients with musculoskeletal disorders. Ninety-eight patients with musculoskeletal disorders referred to physiotherapy with balneotherapy were recruited. The patients received balneotherapy for 20 min 5 times per week for 2 weeks. Blood pressure and pulse were measured at the 0th, 5th, 10th, 20th, and 30th minutes during the 1st and 10th sessions. All patients were subjected to pulmonary function testing before balneotherapy and after the 10th session. It was found that systolic blood pressure decreased between the 10th and 20th minutes of the 1st session and between the 10th and 20th minutes and the 20th and 30th minutes of the 10th session (P < 0.05). Diastolic blood pressure (DBP) decreased and pulse increased during balneotherapy (P < 0.05). DBP increase and pulse decrease were observed during recovery time (P < 0.05). The blood pressure decreased and the pulse increased after the 1st session and after the 10th session (P < 0.05). Pulmonary function improved after balneotherapy (P < 0.05). Conclusions: Balneotherapy may be effective for improving peripheral cardiopulmonary responses in patients with musculoskeletal disorders.
PULMONARY CIRCULATION AT EXERCISE
NAEIJE, R; CHESLER, N
2012-01-01
The pulmonary circulation is a high flow and low pressure circuit, with an average resistance of 1 mmHg.min.L−1 in young adults, increasing to 2.5 mmHg.min.L−1 over 4–6 decades of life. Pulmonary vascular mechanics at exercise are best described by distensible models. Exercise does not appear to affect the time constant of the pulmonary circulation or the longitudinal distribution of resistances. Very high flows are associated with high capillary pressures, up to a 20–25 mmHg threshold associated with interstitial lung edema and altered ventilation/perfusion relationships. Pulmonary artery pressures of 40–50 mmHg, which can be achieved at maximal exercise, may correspond to the extreme of tolerable right ventricular afterload. Distension of capillaries that decrease resistance may be of adaptative value during exercise, but this is limited by hypoxemia from altered diffusion/perfusion relationships. Exercise in hypoxia is associated with higher pulmonary vascular pressures and lower maximal cardiac output, with increased likelihood of right ventricular function limitation and altered gas exchange by interstitial lung edema. Pharmacological interventions aimed at the reduction of pulmonary vascular tone have little effect on pulmonary vascular pressure-flow relationships in normoxia, but may decrease resistance in hypoxia, unloading the right ventricle and thereby improving exercise capacity. Exercise in patients with pulmonary hypertension is associated with sharp increases in pulmonary artery pressure and a right ventricular limitation of aerobic capacity. Exercise stress testing to determine multipoint pulmonary vascular pressures-flow relationships may uncover early stage pulmonary vascular disease. PMID:23105961
Portable Microcomputer Utilization for On-Line Pulmonary Testing
Pugh, R.; Fourre, J.; Karetzky, M.
1981-01-01
A host-remote pulmonary function testing system is described that is flexible, non-dedicated, inexpensive, and readily upgradable. It is applicable for laboratories considering computerization as well as for those which have converted to one of the already available but restricted systems. The remote unit has an 8 slot bus for memory, input-output boards, and an A-D converter. It has its own terminal for manual input and display of computed and measured data which is transmitted via an acoustic modem to a larger microcomputer. The program modules are written in Pascal-Z and/or the supplied Z-80 macro assembler as external procedures.
Chest pain in a young patient: an unusual complication of Epstein-Barr virus.
Raman, Lavanya; Rathod, Krishnaraj Sinhji; Banka, Rajesh
2014-03-31
A 29-year-old man presented with sudden left-sided pleuritic chest pain on a background of sore throat during the preceding week. On examination he had tender cervical lymphadenopathy, he was tachycardic and had a 24 mm Hg blood pressure difference between the left and right arms. Bloods revealed deranged liver function tests and a lymphocytosis. His D-dimer was raised, hence he was treated for presumed pulmonary embolism before imaging was available. Monospot test was positive. He subsequently had both a CT pulmonary angiogram and a CT angiogram of the aorta to exclude pulmonary embolism and aortic dissection. The CT revealed splenomegaly with a large subdiaphragmatic haematoma secondary to splenic rupture. This had likely caused referred pain through diaphragmatic irritation. He was taken to theatre for urgent splenectomy. The unifying diagnosis was infectious mononucleosis complicated by spontaneous splenic rupture secondary to Epstein-Barr virus infection.
Yu, Jie; Zhang, Longju; Luo, Ya; Tang, Yin; Tuo, Fangxu; Yang, Jiaqi; Xu, Jie
2017-04-01
To assess the association of indoor environmental risk factors with respiratory function among adults in an acid rain-plagued city in China where coal use is frequent. The subjects were randomly selected in the winter season. Information on selected home environmental factors was collected through administered questionnaires. Additionally, pulmonary function tests, including Forced Vital Capacity (FVC), Forced Expiratory Volume in 1 s (FEV 1 ), FEV 1 /FVC and Peak Expiratory Flow Rate (PEFR) were also performed in participants. This study showed that, among a variety of risk factors, coal fuel use, cooking oil fumes and active and passive smoking exposure together with asthma in childhood were important factors for deterioration of pulmonary function among adults in the winter season (p < 0.05). Additionally, subjects whose kitchen was located in the living room or bedroom, who opened their windows only occasionally or never, who noted the presence of cooking oil fumes and pests, whose bedroom was shared by 3 or more residents and who kept pets tended to exhibit lower values of FVC, FEV 1 and PEFR values compared with non-exposed counterparts (p < 0.05). This study demonstrated impaired pulmonary function among adults who were exposed to indoor risk factors, such as coal fires and cigarette smoking compared to non-users in the winter season and emphasizes the need for public health efforts to decrease exposure to indoor air pollution.
Pulmonary functions in tannery workers--a cross sectional study.
Chandrasekaran, Vasanthi; Dilara, K; Padmavathi, R
2014-01-01
Tannery workers are at potential exposure to detrimental agents rendering them vulnerable to respiratory and dermal problems. Thus by performing pulmonary functions among leather tannery workers, we can decipher the effect of chromium and leather dust on lung functions and also the decline of respiratory functions with increasing years of exposure to leather dust. Pulmonary functions were assessed for 130 tannery workers and compared with the 130 unexposed office workers. Pulmonary function measurements namely FVC, FEV1, FEF25-75% and PEFR were measured using portable data logging Spirometer (KOKO Spirometer). The observed pulmonary functions of Tannery-workers in this study showed a reduction in FEV1, FVC, FEV1/FVC ratio, FEF25-75 and PEFR in relation to their predicted values and also compared to the unexposed. Smokers showed a decline in pulmonary functions compared to the non smokers because smoking acts as an additional risk factor in the development of respiratory illnesses. It is worthy to mention that the pulmonary function values correlate negatively with the duration of exposure to leather dust. So this study could provide base line information based upon which legal implementation of preventive measures could be undertaken.
Idiopathic pulmonary fibrosis in a Christmas Island nuclear test veteran
Parfrey, H; Babar, J; Fiddler, CA; Chilvers, ER
2010-01-01
We describe the case of a 71-year-old man with idiopathic pulmonary fibrosis (usual interstitial pneumonia (UIP) pattern) diagnosed on clinical, radiological and lung function criteria, in accordance with the American Thoracic Society/European Respiratory Society consensus criteria (2000), who had been in close proximity to three atmospheric nuclear bomb blasts during military service in 1957. He does not have clubbing and clinically and radiologically his lung disease is stable. He also has bladder carcinoma and carotid arteriosclerosis, both recognised consequences of radiation injury. This is the first reported case of UIP in a nuclear test veteran. Awareness of this potential association is important given the current attempts of the British Nuclear Test Veterans Association to gain compensation for claimed injuries. PMID:22797205
Inagaki, Takeshi; Terada, Jiro; Yahaba, Misuzu; Kawata, Naoko; Jujo, Takayuki; Nagashima, Kengo; Sakao, Seiichiro; Tanabe, Nobuhiro; Tatsumi, Koichiro
2018-05-01
The 6-min walk test (6MWT) is commonly performed to assess functional status in patients with chronic thromboembolic pulmonary hypertension. However, changes in heart rate and oxygen saturation (S pO 2 ) patterns during 6MWT in patients with chronic thromboembolic pulmonary hypertension remain unclear. Thirty-one subjects with chronic thromboembolic pulmonary hypertension were retrospectively evaluated to examine the relationships between the change in heart rate (Δheart rate), heart rate acceleration time, slope of heart rate acceleration, heart rate recovery during the first minute after 6MWT (HRR1), change in S pO 2 (ΔS pO 2 ), S pO 2 reduction time, and S pO 2 recovery time during 6MWT, and the severity of pulmonary hemodynamics assessed by right heart catheterization and echocardiography. Subjects with severe chronic thromboembolic pulmonary hypertension had significantly longer heart rate acceleration time (144.9 ± 63.9 s vs 96.0 ± 42.5 s, P = .033), lower Δheart rate (47.4 ± 16.9 vs 61.8 ± 13.6 beats, P = .02), and lower HRR1 (13.3 ± 9.0 beats vs 27.1 ± 9.2 beats, P < .001) compared to subjects with mild chronic thromboembolic pulmonary hypertension. Subjects with severe chronic thromboembolic pulmonary hypertension also had significantly longer S pO 2 reduction time (178.3 ± 70.3 s vs 134.3 ± 58.4 s, P = .03) and S pO 2 recovery time (107.6 ± 35.3 s vs 69.8 ± 32.7 s, P = .004) than did subjects with mild chronic thromboembolic pulmonary hypertension. Multivariate linear regression analysis showed only mean pulmonary arterial pressure independently was associated with heart rate acceleration time and slope of heart rate acceleration. Heart rate and S pO 2 change patterns during 6MWT are predominantly associated with pulmonary hemodynamics in subjects with chronic thromboembolic pulmonary hypertension. Evaluating heart rate and S pO 2 change patterns during 6MWT may serve as a safe and convenient way to follow the change in pulmonary hemodynamics. Copyright © 2018 by Daedalus Enterprises.
Structural basis for pulmonary functional imaging.
Itoh, H; Nakatsu, M; Yoxtheimer, L M; Uematsu, H; Ohno, Y; Hatabu, H
2001-03-01
An understanding of fine normal lung morphology is important for effective pulmonary functional imaging. The lung specimens must be inflated. These include (a) unfixed, inflated lung specimen, (b) formaldehyde fixed lung specimen, (c) fixed, inflated dry lung specimen, and (d) histology specimen. Photography, magnified view, radiograph, computed tomography, and histology of these specimens are demonstrated. From a standpoint of diagnostic imaging, the main normal lung structures consist of airways (bronchi and bronchioles), alveoli, pulmonary vessels, secondary pulmonary lobules, and subpleural pulmonary lymphatic channels. This review summarizes fine radiologic normal lung morphology as an aid to effective pulmonary functional imaging.
Demirci, Hakan; Eniste, Koncuy; Basaran, Ebru Onuker; Ocakoglu, Gokhan; Yilmaz, Zeynep; Tuna, Sumeyye
2017-11-01
Spirometry is known to be a gold standard for the diagnosis of chronic obstructive pulmonary disease (COPD). COPD Assessment Test (CAT) is an eight-item questionnaire currently in use to evaluate patients with COPD. In the present study, we aimed to evaluate if CAT is an adequate tool for screening COPD. In total, 600 persons aging ⩾40 years old were randomly selected from three different family practice units located in the city center. CAT was asked to the participants and a spirometry was used to assess pulmonary obstruction. Pulmonary obstruction was defined as forced expiratory volume in first second/forced vital capacity (FEV1/FVC)<70% and then COPD diagnosis was confirmed with the reversibility test. The relationship between CAT results and pulmonary function test values was evaluated. In this sampling, the prevalence of COPD was 4.2%. Reliability of the CAT in the study group was acceptable (Cronbach's α: 0.84). The CAT scores was significantly higher in patients with COPD (P<0.001). There was a significant negative correlation between CAT score and FEV1, FVC and FEV1/FVC ratio (r=-0.31, P<0.001; r=-0.26, P<0.001; r=0.18, P=0.001). Among smokers, phlegm was the predominating symptom (P=0.01). Sensitivity of CAT was 66.67% and its specificity was 75.15% to determine COPD. CAT is a reliable questionnaire and there is an apparent relationship between the total CAT scores and COPD. However, CAT's ability to screen COPD is limited since it may miss the symptom-free cases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reiss, T.F.; Golden, J.
Pneumocystis carinii pneumonia was suggested by a diffuse, bilateral pulmonary uptake of gallium-67 in an asymptomatic, homosexual male with the antibody to the immunodeficiency virus (HIV) who was undergoing staging evaluation for lymphoma clinically localized to a left inguinal lymph node. Chest radiograph and pulmonary function evaluation, including lung volumes, diffusing capacity and arterial blood gases, were within normal limits. Bronchoalveolar lavage revealed Pneumocystis carinii organisms. In this asymptomatic, HIV-positive patient, active alveolar infection, evidenced by abnormal gallium-67 scanning, predated pulmonary physiologic abnormalities. This observation raises questions concerning the natural history of this disease process and the specificity of physiologicmore » tests for excluding disease. It also has implications for the treatment of neoplasia in the HIV-positive patient population.« less
Tsuchiya, Kazuo; Toyoshima, Mikio; Kamiya, Yosuke; Nakamura, Yutaro; Baba, Satoshi; Suda, Takafumi
2017-01-01
An 85-year-old, never-smoking man presented with exertional dyspnea. He had been exposed to silica dust in the work place. Chest computed tomography revealed bronchial wall thickening without emphysema. A pulmonary function test showed airflow obstruction without impaired gas transfer. Airway hyperresponsiveness and reversibility were not evident. A transbronchial lung biopsy showed findings suggestive of mineral dust exposure, such as fibrosis and slight pigmentation of bronchioles. He was diagnosed with non-smoking chronic obstructive pulmonary disease (COPD) due to occupational exposure to silica dust. His symptoms were improved using an inhaled long-acting bronchodilator. The clinical characteristics of non-smoking COPD are discussed in this report.
Right heart function during simulated altitude in patients with pulmonary arterial hypertension
Seccombe, Leigh M; Chow, Vincent; Zhao, Wei; Lau, Edmund M T; Rogers, Peter G; Ng, Austin C C; Veitch, Elizabeth M; Peters, Matthew J; Kritharides, Leonard
2017-01-01
Objective Patients with pulmonary arterial hypertension (PAH) are often recommended supplemental oxygen for altitude travel due to the possible deleterious effects of hypoxia on pulmonary haemodynamics and right heart function. This includes commercial aircraft travel; however, the direct effects and potential risks are unknown. Methods Doppler echocardiography and gas exchange measures were investigated in group 1 patients with PAH and healthy patients at rest breathing room air and while breathing 15.1% oxygen, at rest for 20 min and during mild exertion. Results The 14 patients with PAH studied were clinically stable on PAH-specific therapy, with functional class II (n=11) and III (n=3) symptoms when tested. Measures of right ventricular size and function were significantly different in the PAH group at baseline as compared to 7 healthy patients (p<0.04). There was no evidence of progressive right ventricular deterioration during hypoxia at rest or under exertion. Pulmonary arterial systolic pressure (PASP) increased in both groups during hypoxia (p<0.01). PASP in hypoxia correlated strongly with baseline PASP (p<0.01). Pressure of arterial oxygen correlated with PASP in hypoxia (p<0.03) but not at baseline, with three patients with PAH experiencing significant desaturation. The duration and extent of hypoxia in this study was tolerated well despite a mild increase in symptoms of breathlessness (p<0.01). Conclusions Non-invasive measures of right heart function in group 1 patients with PAH on vasodilator treatment demonstrated a predictable rise in PASP during short-term simulated hypoxia that was not associated with a deterioration in right heart function. PMID:28123765
Nakatani, S; Garcia, M J; Firstenberg, M S; Rodriguez, L; Grimm, R A; Greenberg, N L; McCarthy, P M; Vandervoort, P M; Thomas, J D
1999-09-01
The study assessed whether hemodynamic parameters of left atrial (LA) systolic function could be estimated noninvasively using Doppler echocardiography. Left atrial systolic function is an important aspect of cardiac function. Doppler echocardiography can measure changes in LA volume, but has not been shown to relate to hemodynamic parameters such as the maximal value of the first derivative of the pressure (LA dP/dt(max)). Eighteen patients in sinus rhythm were studied immediately before and after open heart surgery using simultaneous LA pressure measurements and intraoperative transesophageal echocardiography. Left atrial pressure was measured with a micromanometer catheter, and LA dP/dt(max) during atrial contraction was obtained. Transmitral and pulmonary venous flow were recorded by pulsed Doppler echocardiography. Peak velocity, and mean acceleration and deceleration, and the time-velocity integral of each flow during atrial contraction was measured. The initial eight patients served as the study group to derive a multilinear regression equation to estimate LA dP/dt(max) from Doppler parameters, and the latter 10 patients served as the test group to validate the equation. A previously validated numeric model was used to confirm these results. In the study group, LA dP/dt(max) showed a linear relation with LA pressure before atrial contraction (r = 0.80, p < 0.005), confirming the presence of the Frank-Starling mechanism in the LA. Among transmitral flow parameters, mean acceleration showed the strongest correlation with LA dP/dt(max) (r = 0.78, p < 0.001). Among pulmonary venous flow parameters, no single parameter was sufficient to estimate LA dP/dt(max) with an r2 > 0.30. By stepwise and multiple linear regression analysis, LA dP/dt(max) was best described as follows: LA dP/dt(max) = 0.1 M-AC +/- 1.8 P-V - 4.1; r = 0.88, p < 0.0001, where M-AC is the mean acceleration of transmitral flow and P-V is the peak velocity of pulmonary venous flow during atrial contraction. This equation was tested in the latter 10 patients of the test group. Predicted and measured LA dP/dt(max) correlated well (r = 0.90, p < 0.0001). Numerical simulation verified that this relationship held across a wide range of atrial elastance, ventricular relaxation and systolic function, with LA dP/dt(max) predicted by the above equation with r = 0.94. A combination of transmitral and pulmonary venous flow parameters can provide a hemodynamic assessment of LA systolic function.
NASA Technical Reports Server (NTRS)
Nakatani, S.; Garcia, M. J.; Firstenberg, M. S.; Rodriguez, L.; Grimm, R. A.; Greenberg, N. L.; McCarthy, P. M.; Vandervoort, P. M.; Thomas, J. D.
1999-01-01
OBJECTIVES: The study assessed whether hemodynamic parameters of left atrial (LA) systolic function could be estimated noninvasively using Doppler echocardiography. BACKGROUND: Left atrial systolic function is an important aspect of cardiac function. Doppler echocardiography can measure changes in LA volume, but has not been shown to relate to hemodynamic parameters such as the maximal value of the first derivative of the pressure (LA dP/dt(max)). METHODS: Eighteen patients in sinus rhythm were studied immediately before and after open heart surgery using simultaneous LA pressure measurements and intraoperative transesophageal echocardiography. Left atrial pressure was measured with a micromanometer catheter, and LA dP/dt(max) during atrial contraction was obtained. Transmitral and pulmonary venous flow were recorded by pulsed Doppler echocardiography. Peak velocity, and mean acceleration and deceleration, and the time-velocity integral of each flow during atrial contraction was measured. The initial eight patients served as the study group to derive a multilinear regression equation to estimate LA dP/dt(max) from Doppler parameters, and the latter 10 patients served as the test group to validate the equation. A previously validated numeric model was used to confirm these results. RESULTS: In the study group, LA dP/dt(max) showed a linear relation with LA pressure before atrial contraction (r = 0.80, p < 0.005), confirming the presence of the Frank-Starling mechanism in the LA. Among transmitral flow parameters, mean acceleration showed the strongest correlation with LA dP/dt(max) (r = 0.78, p < 0.001). Among pulmonary venous flow parameters, no single parameter was sufficient to estimate LA dP/dt(max) with an r2 > 0.30. By stepwise and multiple linear regression analysis, LA dP/dt(max) was best described as follows: LA dP/dt(max) = 0.1 M-AC +/- 1.8 P-V - 4.1; r = 0.88, p < 0.0001, where M-AC is the mean acceleration of transmitral flow and P-V is the peak velocity of pulmonary venous flow during atrial contraction. This equation was tested in the latter 10 patients of the test group. Predicted and measured LA dP/dt(max) correlated well (r = 0.90, p < 0.0001). Numerical simulation verified that this relationship held across a wide range of atrial elastance, ventricular relaxation and systolic function, with LA dP/dt(max) predicted by the above equation with r = 0.94. CONCLUSIONS: A combination of transmitral and pulmonary venous flow parameters can provide a hemodynamic assessment of LA systolic function.
Brunette, Amanda M; Holm, Kristen E; Wamboldt, Frederick S; Kozora, Elizabeth; Moser, David J; Make, Barry J; Crapo, James D; Meschede, Kimberly; Weinberger, Howard D; Moreau, Kerrie L; Bowler, Russell P; Hoth, Karin F
2018-05-01
This study examined the association of perceived cognitive difficulties with objective cognitive performance in former smokers. We hypothesized that greater perceived cognitive difficulties would be associated with poorer performance on objective executive and memory tasks. Participants were 95 former smokers recruited from the COPDGene study. They completed questionnaires (including the Cognitive Difficulties Scale [CDS] and the Hospital Anxiety and Depression Scale [HADS]), neuropsychological assessment, and pulmonary function testing. Pearson correlations and t-tests were conducted to examine the bivariate association of the CDS (total score and subscales for attention/concentration, praxis, delayed recall, orientation for persons, temporal orientation, and prospective memory) with each domain of objective cognitive functioning (memory recall, executive functioning/processing speed, visuospatial processing, and language). Simultaneous multiple linear regression was used to further examine all statistically significant bivariate associations. The following covariates were included in all regression models: age, sex, pack-years, premorbid functioning (WRAT-IV Reading), HADS total score, and chronic obstructive pulmonary disease (COPD) status (yes/no based on GOLD criteria). In regression models, greater perceived cognitive difficulties overall (using CDS total score) were associated with poorer performance on executive functioning/processing speed tasks (b = -0.07, SE = 0.03, p = .037). Greater perceived cognitive difficulties on the CDS praxis subscale were associated with poorer performance on executive functioning/processing speed tasks (b = -3.65, SE = 1.25, p = .005), memory recall tasks (b = -4.60, SE = 1.75, p = .010), and language tasks (b = -3.89, SE = 1.39, p = .006). Clinicians should be aware that cognitive complaints may be indicative of problems with the executive functioning/processing speed and memory of former smokers with and without COPD.
Thoracic magnetic resonance imaging: pulmonary thromboembolism.
Fink, Christian; Henzler, Thomas; Shirinova, Aysel; Apfaltrer, Paul; Wasser, Klaus
2013-05-01
Ongoing technical developments have substantially improved the potential of magnetic resonance imaging (MRI) in the assessment of the pulmonary circulation. These developments includes improved magnet and hardware design, new k-space sampling techniques (ie, parallel imaging), and alternative contrast materials. With these techniques, not only can pulmonary vessels be visualized by MR angiography with high spatial resolution but also the perfusion of the lungs and its changes in relation to pulmonary thromboembolism (PE) can be assessed. Considering venous thromboembolism as a systemic disease, MR venography might be added for the diagnosis of underlying deep venous thrombosis. A unique advantage of MRI over other imaging tests is its potential to evaluate changes in cardiac function as a result of obstruction of the pulmonary circulation, which may have a significant impact on patient monitoring and treatment. Finally, MRI does not involve radiation, which is advantageous, especially in young patients. Over the years, a number of studies have shown promising results not only for MR angiography but also for MRI of lung perfusion and for MR venography. This review article summarizes and discusses the current evidence on pulmonary MRI for patients with suspected PE.
Otsuka, K; Norboo, T; Otsuka, Y; Higuchi, H; Hayajiri, M; Narushima, C; Sato, Y; Tsugoshi, T; Murakami, S; Wada, T; Ishine, M; Okumiya, K; Matsubayashi, K; Yano, S; Chogyal, T; Angchuk, D; Ichihara, K; Cornélissen, G; Halberg, F
2005-10-01
Effects of high altitude on arterial stiffness and neuro-cardio-pulmonary function were studied. Blood pressure (BP) and heart rate (HR) were measured in a sitting position on resting Ladakhis, living at an altitude of 3250-4647 m (Phey village, 3250 m: 17 men and 55 women; Chumathang village, 4193 m: 29 men and 47 women; Sumdo village, 4540 m: 38 men and 57 women; and Korzok village, 4647 m: 84 men and 70 women). The neuro-cardio-pulmonary function, including the Kohs block design test, the Up and Go, the Functional Reach and the Button tests, was examined in 40 elderly subjects (19 men and 21 women, mean age: 74.7 +/- 3.3 years) in Leh, Ladakh (altitude: 3524 m), for comparison with 324 elderly citizens (97 men and 227 women, mean age: 80.7 +/- 4.7 years) of Tosa, Japan (altitude: 250 m). Cardio-Ankle Vascular Index (CAVI) was measured as the heart-ankle pulse wave velocity (PWV) in these subjects using a VaSera CAVI instrument (Fukuda Denshi, Tokyo). SpO(2) decreased while Hb and diastolic BP increased with increasing altitude. At higher altitude, residents were younger and leaner. Women in Leh vs. Tosa had a poorer cognitive function, estimated by the Kohs block design test (3.7 +/- 3.6 vs. 16.4 +/- 9.6 points, P < 0.0001) and poorer ADL functions (Functional Reach: 13.7 +/- 7.0 cm vs. 25.3 +/- 8.7 cm, P < 0.0001; Button test: 22.5 +/- 4.8 vs. 14.8 +/- 5.7 s, P < 0.0001). Time estimation was shorter at high altitude (60-s estimation with counting: 41.1% shorter in men and 23.0% shorter in women). A higher voltage of the QRS complex was observed in the ECG of Leh residents, but two times measurement of CAVI showed no statistically significant differences between Leh and Tosa (two times of CAVI measures; 9.49 vs. 10.01 m/s and 9.41 vs. 10.05 m/s, respectively), suggesting that most residents succeed to adapt sufficiently to the high-altitude environment. However, correlation of CAVI with age shows several cases who show an extreme increase in CAVI. Thus, for the prevention of stroke and other adverse cardiovascular outcomes, including dementia, CAVI may be very useful, especially at high altitude. In conclusion, elderly people living at high altitude have a higher risk of cardiovascular disease than low-latitude peers. To determine how these indices are associated with maintained cognitive function deserves further study by the longitudinal follow-up of these communities in terms of longevity and aging in relation to their neuro-cardio-pulmonary function.
The effect of exposure to SO2 on the respiratory system of power-station workers.
Froom, P; Sackstein, G; Cohen, C; Lerman, Y; Kristal-Boneh, E; Ribak, J
1998-01-01
Sulfur dioxide (SO2) is generally recognized as a respiratory irritant, but its effects if any at low levels of exposure are uncertain. We studied 38 power station technicians exposed to 0.8 ppm (parts per million) 8-h weighted levels of sulfur dioxide, and compared them to workers performing similar tasks without such exposure. Those exposed complained 5.8 times more frequently of cough (95% CI =1.8-20.6, P < 0.001), and also had significantly more sputum production. There was also a trend for increasing prevalence of dyspnea. On the other hand there was no decrease in pulmonary function test values. In the eight exposed subjects who complained of dyspnea, there was a significant decrease in pulmonary flow values. We conclude that power station workers exposed to low levels of SO2 have increased respiratory symptoms, and deserve compensation if their symptoms become chronic. The pulmonary function tests were not different from the control subjects, but there may be a small group who are prone to long-term morbidity. Additional studies are warranted to confirm our findings, and to define immediate and long-term morbidity due to low exposure to SO2.
Electrophysiological assessment in patients with long term hypoxia.
Ilik, Faik; Pazarli, Ahmet C; Kayhan, Fatih; Karamanli, Harun; Ozlece, Hatice K
2016-01-01
To evaluate visual evoked potentials (VEP) patterns in chronic obstructive pulmonary disease (COPD) patients who were compliant with supplemental oxygen treatment relative to non-compliant COPD patients. This prospective study protocol was reviewed and approved by the local ethical committee of Selcuk University and the research was performed in the Department of Neurology, Elbistan State Hospital, Kahramanmaras, Turkey from May to October 2014. Blood gas measurements and pulmonary function tests were carried out in patients with advanced stage COPD. The VEP was assessed in both eyes in both compliant and non-compliant patients. The study included 43 patients; 24 (55.8%) of the patients were not in compliance with their supplemental oxygen treatment, while 19 patients (44.2%) received adequate oxygen treatment. There was no statistically significant difference between patients with regards to pulmonary function test results and blood gas measurements. The VEP latency was significantly greater in both eyes of the non-compliant patients. Previous studies have reported prolonged VEP latencies in inflammatory diseases of the central nervous system. Similar electrophysiological findings were observed in our study and we propose that this may be due to oxidative stress, and inflammation that occurs secondary to chronic ischemia.
McEvoy, Cindy T; Schilling, Diane; Clay, Nakia; Jackson, Keith; Go, Mitzi D; Spitale, Patricia; Bunten, Carol; Leiva, Maria; Gonzales, David; Hollister-Smith, Julie; Durand, Manuel; Frei, Balz; Buist, A Sonia; Peters, Dawn; Morris, Cynthia D; Spindel, Eliot R
2014-05-01
Maternal smoking during pregnancy adversely affects offspring lung development, with lifelong decreases in pulmonary function and increased asthma risk. In a primate model, vitamin C blocked some of the in-utero effects of nicotine on lung development and offspring pulmonary function. To determine if newborns of pregnant smokers randomized to receive daily vitamin C would have improved results of pulmonary function tests (PFTs) and decreased wheezing compared with those randomized to placebo. Randomized, double-blind trial conducted in 3 sites in the Pacific Northwest between March 2007 and January 2011. One hundred fifty-nine newborns of randomized pregnant smokers (76 vitamin C treated and 83 placebo treated) and 76 newborns of pregnant nonsmokers were studied with newborn PFTs. Follow-up assessment including wheezing was assessed through age 1 year, and PFTs were performed at age 1 year. Pregnant women were randomized to receive vitamin C (500 mg/d) (n = 89) or placebo (n = 90). The primary outcome was measurement of newborn pulmonary function (ratio of the time to peak tidal expiratory flow to expiratory time [TPTEF:TE] and passive respiratory compliance per kilogram [Crs/kg]) within 72 hours of age. Secondary outcomes included incidence of wheezing through age 1 year and PFT results at age 1 year. A subgroup of pregnant smokers and nonsmokers had genotyping performed. Newborns of women randomized to vitamin C (n = 76), compared with those randomized to placebo (n = 83), had improved pulmonary function as measured by TPTEF:TE (0.383 vs 0.345 [adjusted 95% CI for difference, 0.011-0.062]; P = .006) and Crs/kg (1.32 vs 1.20 mL/cm H2O/kg [95% CI, 0.02-0.20]; P = .01). Offspring of women randomized to vitamin C had significantly decreased wheezing through age 1 year (15/70 [21%] vs 31/77 [40%]; relative risk, 0.56 [95% CI, 0.33-0.95]; P = .03). There were no significant differences in the 1-year PFT results between the vitamin C and placebo groups. The effect of maternal smoking on newborn lung function was associated with maternal genotype for the α5 nicotinic receptor (rs16969968) (P < .001 for interaction). Supplemental vitamin C taken by pregnant smokers improved newborn PFT results and decreased wheezing through 1 year in the offspring. Vitamin C in pregnant smokers may be an inexpensive and simple approach to decrease the effects of smoking in pregnancy on newborn pulmonary function and respiratory morbidities. clinicaltrials.gov Identifier: NCT00632476.
Duke, Joseph W; Elliott, Jonathan E; Laurie, Steven S; Beasley, Kara M; Mangum, Tyler S; Hawn, Jerold A; Gladstone, Igor M; Lovering, Andrew T
2014-09-01
Adults with a history of very preterm birth (<32 wk gestational age; PRET) have reduced lung function and significantly lower lung diffusion capacity for carbon monoxide (DLCO) relative to individuals born at term (CONT). Low DLCO may predispose PRET to diffusion limitation during exercise, particularly while breathing hypoxic gas because of a reduced O2 driving gradient and pulmonary capillary transit time. We hypothesized that PRET would have significantly worse pulmonary gas exchange efficiency [i.e., increased alveolar-to-arterial Po2 difference (AaDO2)] during exercise breathing room air or hypoxic gas (FiO2 = 0.12) compared with CONT. To test this hypothesis, we compared the AaDO2 in PRET (n = 13) with a clinically mild reduction in DLCO (72 ± 7% of predicted) and CONT (n = 14) with normal DLCO (105 ± 10% of predicted) pre- and during exercise breathing room air and hypoxic gas. Measurements of temperature-corrected arterial blood gases, and direct measure of O2 saturation (SaO2), were made prior to and during exercise at 25, 50, and 75% of peak oxygen consumption (V̇o2peak) while breathing room air and hypoxic gas. In addition to DLCO, pulmonary function and exercise capacity were significantly less in PRET. Despite PRET having low DLCO, no differences were observed in the AaDO2 or SaO2 pre- or during exercise breathing room air or hypoxic gas compared with CONT. Although our findings were unexpected, we conclude that reduced pulmonary function and low DLCO resulting from very preterm birth does not cause a measureable reduction in pulmonary gas exchange efficiency. Copyright © 2014 the American Physiological Society.
Nassar, Seham Zakaria; Hassaan, Passainte S; Abdelmonsif, Doaa A; ElAchy, Samar Nabil
2018-05-15
Cerium oxide nanoparticles (CeO 2 NPs) have been recently introduced into the medical field for their antioxidant properties. The ability of CeO 2 NPs alone or in combination with spironolactone (SP) to attenuate monocrotaline (MCT)-induced pulmonary hypertension and associated right ventricular hypertrophy was studied in rats. A special emphasis was given to endothelin-1 pathway. Pulmonary hypertension was induced in albino rats by a single subcutaneous injection of MCT (60 mg/kg). Rats received either single CeO 2 NPs therapy or combined therapy with SP for 2 weeks. CeO 2 NPs improved pulmonary function tests with concomitant decrease in serum endothelin-1 and pulmonary expression of endothelin-1 and its receptor ETAR. Besides, CeO 2 NPs diminished MCT-induced right ventricular hypertrophy and reduced cardiac oxidative stress and apoptosis. CeO 2 NPs could improve pulmonary hypertension and associated right ventricular hypertrophy with no additive value for SP. Besides being an antioxidant, CeO 2 NPs work through endothelin-1 pathway to improve pulmonary hypertension. Copyright © 2018 Elsevier Inc. All rights reserved.
Lung adenocarcinoma mimicking pulmonary fibrosis-a case report.
Mehić, Bakir; Duranović Rayan, Lina; Bilalović, Nurija; Dohranović Tafro, Danina; Pilav, Ilijaz
2016-09-13
Lung cancer is usually presented with cough, dyspnea, pain and weight loss, which is overlapping with symptoms of other lung diseases such as pulmonary fibrosis. Pulmonary fibrosis shows characteristic reticular and nodular pattern, while lung cancers are mostly presented with infiltrative mass, thick-walled cavitations or a solitary nodule with spiculated borders. If the diagnosis is established based on clinical symptoms and CT findings, it would be a misapprehension. We report a case of lung adenocarcinoma whose symptoms as well as clinical images overlapped strongly with pulmonary fibrosis. The patient's non-productive cough, progressive dyspnea, restrictive pattern of pulmonary function test and CT scans (showing reticular interstitial opacities) were all indicative of pulmonary fibrosis. The patient underwent a treatment consisting of corticosteroids and antibiotics, to no avail. Histopathology of the lung showed that the patient suffered from mucinous adenocarcinoma. Albeit the immunohistochemical staining was not consistent with lung adenocarcinoma, tumor's morphological characteristics were consistent, and were used to make the definitive diagnosis. Given the fact that radiography cannot always make a clear-cut difference between pulmonary fibrosis and lung adenocarcinomas, and that clinical symptoms often overlap, histological examination should be considered as gold standard for diagnosis of lung adenocarcinoma.
Engineered cell and tissue models of pulmonary fibrosis.
Sundarakrishnan, Aswin; Chen, Ying; Black, Lauren D; Aldridge, Bree B; Kaplan, David L
2018-04-01
Pulmonary fibrosis includes several lung disorders characterized by scar formation and Idiopathic Pulmonary Fibrosis (IPF) is a particularly severe form of pulmonary fibrosis of unknown etiology with a mean life expectancy of 3years' post-diagnosis. Treatments for IPF are limited to two FDA approved drugs, pirfenidone and nintedanib. Most lead candidate drugs that are identified in pre-clinical animal studies fail in human clinical trials. Thus, there is a need for advanced humanized in vitro models of the lung to improve candidate treatments prior to moving to human clinical trials. The development of 3D tissue models has created systems capable of emulating human lung structure, function, and cell and matrix interactions. The specific models accomplish these features and preliminary studies conducted using some of these systems have shown potential for in vitro anti-fibrotic drug testing. Further characterization and improvements will enable these tissue models to extend their utility for in vitro drug testing, to help identify signaling pathways and mechanisms for new drug targets, and potentially reduce animal models as standard pre-clinical models of study. In the current review, we contrast different in vitro models based on increasing dimensionality (2D, 2.5D and 3D), with added focus on contemporary 3D pulmonary models of fibrosis. Copyright © 2017. Published by Elsevier B.V.
Effects of water immersion to the neck on pulmonary circulation and tissue volume in man
NASA Technical Reports Server (NTRS)
Begin, R.; Epstein, M.; Sackner, M. A.; Levinson, R.; Dougherty, R.; Duncan, D.
1976-01-01
A rapid noninvasive breathing method is used to obtain serial measurements of the pulmonary capillary blood flow, diffusing capacity per unit of alveolar volume, combined pulmonary tissue plus capillary volume, functional residual capacity, and oxygen consumption in five normal subjects undergoing 6 h of sitting, 4 h of sitting while immersed to the neck in thermoneutral water, and 4 h of lying in thermoneutral water to the neck. The rebreathing method employed a test gas mixture containing 0.5% C2H2, 0.3% C(18)O, 10% He, 21% O2, and balance N2. It is shown that immersion to the neck in the seated posture results in significant increases in sodium excretion cardiac output, and diffusing capacity per unit of alveolar volume. The pulmonary tissue plus capillary volume did not change, demonstrating that the central vascular engorgement induced by water immersion is not accompanied by significant extravasation of fluid into the pulmonary interstitial space.
Jacob, Joseph; Bartholmai, Brian J; Rajagopalan, Srinivasan; Brun, Anne Laure; Egashira, Ryoko; Karwoski, Ronald; Kokosi, Maria; Wells, Athol U; Hansell, David M
2016-11-23
To evaluate computer-based computer tomography (CT) analysis (CALIPER) against visual CT scoring and pulmonary function tests (PFTs) when predicting mortality in patients with connective tissue disease-related interstitial lung disease (CTD-ILD). To identify outcome differences between distinct CTD-ILD groups derived following automated stratification of CALIPER variables. A total of 203 consecutive patients with assorted CTD-ILDs had CT parenchymal patterns evaluated by CALIPER and visual CT scoring: honeycombing, reticular pattern, ground glass opacities, pulmonary vessel volume, emphysema, and traction bronchiectasis. CT scores were evaluated against pulmonary function tests: forced vital capacity, diffusing capacity for carbon monoxide, carbon monoxide transfer coefficient, and composite physiologic index for mortality analysis. Automated stratification of CALIPER-CT variables was evaluated in place of and alongside forced vital capacity and diffusing capacity for carbon monoxide in the ILD gender, age physiology (ILD-GAP) model using receiver operating characteristic curve analysis. Cox regression analyses identified four independent predictors of mortality: patient age (P < 0.0001), smoking history (P = 0.0003), carbon monoxide transfer coefficient (P = 0.003), and pulmonary vessel volume (P < 0.0001). Automated stratification of CALIPER variables identified three morphologically distinct groups which were stronger predictors of mortality than all CT and functional indices. The Stratified-CT model substituted automated stratified groups for functional indices in the ILD-GAP model and maintained model strength (area under curve (AUC) = 0.74, P < 0.0001), ILD-GAP (AUC = 0.72, P < 0.0001). Combining automated stratified groups with the ILD-GAP model (stratified CT-GAP model) strengthened predictions of 1- and 2-year mortality: ILD-GAP (AUC = 0.87 and 0.86, respectively); stratified CT-GAP (AUC = 0.89 and 0.88, respectively). CALIPER-derived pulmonary vessel volume is an independent predictor of mortality across all CTD-ILD patients. Furthermore, automated stratification of CALIPER CT variables represents a novel method of prognostication at least as robust as PFTs in CTD-ILD patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bergin, C.J.; Bell, D.Y.; Coblentz, C.L.
1989-06-01
The appearances of the lungs on radiographs and computed tomographic (CT) scans were correlated with degree of uptake on gallium scans and results of pulmonary function tests (PFTs) in 27 patients with sarcoidosis. CT scans were evaluated both qualitatively and quantitatively. Patients were divided into five categories on the basis of the pattern of abnormality at CT: 1 = normal (n = 4); 2 = segmental air-space disease (n = 4); 3 = spherical (alveolar) masslike opacities (n = 4); 4 = multiple, discrete, small nodules (n = 6); and 5 = distortion of parenchymal structures (fibrotic end-stage sarcoidosis) (nmore » = 9). The percentage of the volume judged to be abnormal (CT grade) was correlated with PFT results for each CT and radiographic category. CT grades were also correlated with gallium scanning results and percentage of lymphocytes recovered from bronchoalveolar lavage (BAL). Patients in CT categories 1 and 2 had normal lung function, those in category 3 had mild functional impairment, and those in categories 4 and 5 showed moderate to severe dysfunction. The overall CT grade correlated well with PFT results expressed as a percentage of the predicted value. In five patients, CT scans showed extensive parenchymal disease not seen on radiographs. CT grades did not correlate with the results of gallium scanning or BAL lymphocytes. The authors conclude that patterns of parenchymal sarcoidosis seen at CT correlate with the PFT results and can be used to indicate respiratory impairment.« less
Gotway, Michael B; Golden, Jeffrey A; LaBerge, Jeanne M; Webb, W Richard; Reddy, Gautham P; Wilson, Mark W; Kerlan, Robert K; Gordon, Roy L
2002-01-01
To determine the short- and long-term improvement in airflow dynamics in patients undergoing tracheobronchial stent placement for benign airway stenoses. Twenty-two patients underwent 34 tracheal and/or bronchial stent placement procedures for benign airway stenoses and had the results of pulmonary function tests available. Stent placement indications included bronchomalacia after lung transplantation (n = 11), postintubation stenoses (n = 6), relapsing polychondritis (n = 2), and 1 each of tracheomalacia, tracheal compression, and histoplasmosis. Six patients underwent more than one stent placement procedure (range: 2-7 procedures). The mean forced expiratory volume in one second (FEV(1) ), forced expiratory flow rate in the midportion of the forced vital capacity curve (FEF(25-75) ), forced vital capacity, and peak flow (PF) rate obtained before stent placement were compared with those immediately after stent placement and with those measurements most remote from stent placement using the paired two-tailed test. All patients reported improved respiratory function immediately after stent placement. The mean FEV(1), FEF(25-75), and PF rate improved significantly (p < 0.001, p = 0.002, and p = 0.009, respectively) after stent placement. On long-term follow-up averaging 15 months after stent placement, these parameters declined despite patients' subjective sense of improvement. Segregating the population into transplant and nontransplant airway stenosis etiologies, however, FEF(25-75) and PF rate remained significantly improved (p = 0.045, p = 0.027, respectively), over the long term for the latter. FEV increased after subsequent stent placements for patients receiving multiple stents. Stent placement for benign tracheobronchial stenoses provides significant immediate improvement in airflow dynamics. Long-term improvement in airflow obstruction may be expected, and additional stent placements may further improve pulmonary function.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brennan, Douglas; Schubert, Leah; Diot, Quentin
Purpose: A new form of functional imaging has been proposed in the form of 4-dimensional computed tomography (4DCT) ventilation. Because 4DCTs are acquired as part of routine care for lung cancer patients, calculating ventilation maps from 4DCTs provides spatial lung function information without added dosimetric or monetary cost to the patient. Before 4DCT-ventilation is implemented it needs to be clinically validated. Pulmonary function tests (PFTs) provide a clinically established way of evaluating lung function. The purpose of our work was to perform a clinical validation by comparing 4DCT-ventilation metrics with PFT data. Methods and Materials: Ninety-eight lung cancer patients withmore » pretreatment 4DCT and PFT data were included in the study. Pulmonary function test metrics used to diagnose obstructive lung disease were recorded: forced expiratory volume in 1 second (FEV1) and FEV1/forced vital capacity. Four-dimensional CT data sets and spatial registration were used to compute 4DCT-ventilation images using a density change–based and a Jacobian-based model. The ventilation maps were reduced to single metrics intended to reflect the degree of ventilation obstruction. Specifically, we computed the coefficient of variation (SD/mean), ventilation V20 (volume of lung ≤20% ventilation), and correlated the ventilation metrics with PFT data. Regression analysis was used to determine whether 4DCT ventilation data could predict for normal versus abnormal lung function using PFT thresholds. Results: Correlation coefficients comparing 4DCT-ventilation with PFT data ranged from 0.63 to 0.72, with the best agreement between FEV1 and coefficient of variation. Four-dimensional CT ventilation metrics were able to significantly delineate between clinically normal versus abnormal PFT results. Conclusions: Validation of 4DCT ventilation with clinically relevant metrics is essential. We demonstrate good global agreement between PFTs and 4DCT-ventilation, indicating that 4DCT-ventilation provides a reliable assessment of lung function. Four-dimensional CT ventilation enables exciting opportunities to assess lung function and create functional avoidance radiation therapy plans. The present work provides supporting evidence for the integration of 4DCT-ventilation into clinical trials.« less
Demirçelik, Muhammed Bora; Çetin, Mustafa; Çiçekcioğlu, Hülya; Uçar, Özgül; Duran, Mustafa
2014-05-01
We aimed to investigate effects of left ventricular diastolic dysfunction on left atrial appendage functions, spontaneous echo contrast and thrombus formation in patients with nonvalvular atrial fibrillation. In 58 patients with chronic nonvalvular atrial fibrilation and preserved left ventricular systolic function, left atrial appendage functions, left atrial spontaneous echo contrast grading and left ventricular diastolic functions were evaluated using transthoracic and transoesophageal echocardiogram. Patients divided in two groups: Group D (n=30): Patients with diastolic dysfunction, Group N (n=28): Patients without diastolic dysfunction. Categorical variables in two groups were evaluated with Pearson's chi-square or Fisher's exact test. The significance of the lineer correlation between the degree of spontaneous echo contrast (SEC) and clinical measurements was evaluated with Spearman's correlation analysis. Peak pulmonary vein D velocity of the Group D was significantly higher than the Group N (p=0.006). However, left atrial appendage emptying velocity, left atrial appendage lateral wall velocity, peak pulmonary vein S, pulmonary vein S/D ratio were found to be significantly lower in Group D (p=0.028, p<0.001, p<0.001; p<0.001). Statistically significant negative correlation was found between SEC in left atrium and left atrial appendage emptying, filling, pulmonary vein S/D levels and lateral wall velocities respectively (r=-0.438, r=-0.328, r=-0.233, r=-0.447). Left atrial appendage emptying, filling, pulmonary vein S/D levels and lateral wall velocities were significantly lower in SEC 2-3-4 than SEC 1 (p=0.003, p=0.029, p<0.001, p=0.002). In patients with nonvalvular atrial fibrillation and preserved left ventricular ejection fraction, left atrial appendage functions are decreased in patients with left ventricular diastolic dysfunction. Left ventricular diastolic dysfunction may constitute a potential risk for formation of thrombus and stroke.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keogh, B.A.; Hunninghake, G.W.; Line, B.R.
1983-08-01
Current concepts of the pathogenesis of pulmonary sarcoidosis suggest that a mononuclear cell alveolitis, comprised of activated T-lymphocytes and activated alveolar macrophages, precedes and modulates the formation of granuloma and fibrosis. To evaluate the natural history of this alveolitis and determine the relationship it has to subsequent changes in lung function, 19 untreated patients with pulmonary sarcoidosis without extrapulmonary manifestations were studied with bronchoalveolar lavage, /sup 67/Ga scanning, and pulmonary function tests to evaluate lung T-cells, lung alveolar macrophages, and lung function, respectively. In patients with sarcoidosis, low intensity alveolitis (lung T-cells less than or equal to 28% of allmore » lung effector cells and/or /sup 67/Ga scan negative) was much more common (80% of all observations) than high intensity alveolitis (lung T-cells greater than 28% and /sup 67/Ga scan positive, 20% of all observations). Conventional clinical, roentgenographic, or physiologic studies could not predict the alveolitis status. Interestingly, of the 51 alveolitis evaluations in the 19 patients, there were 24 occurrences (47%) where the alveolitis was ''split,'' i.e., /sup 67/Ga scans positive and T-cells low (39%) or /sup 67/Ga negative and T-cells high (8%). Most untreated patients with sarcoidosis without extrapulmonary symptoms may have some inflammatory processes ongoing in their alveolar structures. Overall, whenever a high intensity alveolitis episode occurred, it was followed by deterioration over the next 6 months in at least one lung function parameter. A low intensity alveolitis episode was followed by functional deterioration only 8% of the time. The alveolitis parameters (lavage and /sup 67/Ga scanning) clearly predicted prognosis. These observations should prove useful in understanding the natural history of pulmonary sarcoidosis, in staging patients with this disease, and in making rational therapy decisions.« less
Maioli, Maria Christina Paixão; Soares, Andrea Ribeiro; Bedirian, Ricardo; Alves, Ursula David; de Lima Marinho, Cirlene; Lopes, Agnaldo José
2015-01-01
Objective To evaluate the association between clinical, pulmonary, and cardiovascular findings in patients with sickle cell disease and, secondarily, to compare these findings between sickle cell anemia patients and those with other sickle cell diseases. Methods Fifty-nine adults were included in this cross-sectional study; 47 had sickle cell anemia, and 12 had other sickle cell diseases. All patients underwent pulmonary function tests, chest computed tomography, and echocardiography. Results Abnormalities on computed tomography, echocardiography, and pulmonary function tests were observed in 93.5%, 75.0%; and 70.2% of patients, respectively. A higher frequency of restrictive abnormalities was observed in patients with a history of acute chest syndrome (85% vs. 21.6%; p-value < 0.0001) and among patients with increased left ventricle size (48.2% vs. 22.2%; p-value = 0.036), and a higher frequency of reduced respiratory muscle strength was observed in patients with a ground-glass pattern (33.3% vs. 4.3%; p-value = 0.016). Moreover, a higher frequency of mosaic attenuation was observed in patients with elevated tricuspid regurgitation velocity (61.1% vs. 24%; p-value = 0.014). Compared to patients with other sickle cell diseases, sickle cell anemia patients had suffered increased frequencies of acute pain episodes, and acute chest syndrome, and exhibited mosaic attenuation on computed tomography, and abnormalities on echocardiography. Conclusion A significant interrelation between abnormalities of the pulmonary and cardiovascular systems was observed in sickle cell disease patients. Furthermore, the severity of the cardiopulmonary parameters among patients with sickle cell anemia was greater than that of patients with other sickle cell diseases. PMID:26969771
Oh, Dongha; Kim, Gayeong; Lee, Wanhee; Shin, Mary Myong Sook
2016-01-01
[Purpose] This study evaluated the effects of inspiratory muscle training on pulmonary function, deep abdominal muscle thickness, and balance ability in stroke patients. [Subjects] Twenty-three stroke patients were randomly allocated to an experimental (n = 11) or control group (n = 12). [Methods] The experimental group received inspiratory muscle training-based abdominal muscle strengthening with conventional physical therapy; the control group received standard abdominal muscle strengthening with conventional physical therapy. Treatment was conducted 20 minutes per day, 3 times per week for 6 weeks. Pulmonary function testing was performed using an electronic spirometer. Deep abdominal muscle thickness was measured by ultrasonography. Balance was measured using the Berg balance scale. [Results] Forced vital capacity, forced expiratory volume in 1 second, deep abdominal muscle thickness, and Berg balance scale scores were significantly improved in the experimental group than in the control group. [Conclusion] Abdominal muscle strengthening accompanied by inspiratory muscle training is recommended to improve pulmonary function in stroke patients, and may also be used as a practical adjunct to conventional physical therapy. PMID:26957739
Prediction of Spirometric Forced Expiratory Volume (FEV1) Data Using Support Vector Regression
NASA Astrophysics Data System (ADS)
Kavitha, A.; Sujatha, C. M.; Ramakrishnan, S.
2010-01-01
In this work, prediction of forced expiratory volume in 1 second (FEV1) in pulmonary function test is carried out using the spirometer and support vector regression analysis. Pulmonary function data are measured with flow volume spirometer from volunteers (N=175) using a standard data acquisition protocol. The acquired data are then used to predict FEV1. Support vector machines with polynomial kernel function with four different orders were employed to predict the values of FEV1. The performance is evaluated by computing the average prediction accuracy for normal and abnormal cases. Results show that support vector machines are capable of predicting FEV1 in both normal and abnormal cases and the average prediction accuracy for normal subjects was higher than that of abnormal subjects. Accuracy in prediction was found to be high for a regularization constant of C=10. Since FEV1 is the most significant parameter in the analysis of spirometric data, it appears that this method of assessment is useful in diagnosing the pulmonary abnormalities with incomplete data and data with poor recording.
The safety and immunogenicity of influenza vaccine in children with asthma in Mexico.
Pedroza, Alvaro; Huerta, José G; Garcia, Maria de la Luz; Rojas, Arsheli; López-Martínez, Irma; Penagos, Martín; Franco-Paredes, Carlos; Deroche, Christele; Mascareñas, Cesar
2009-07-01
The morbidity and mortality associated with influenza is substantial in children with asthma. There are no available data on the safety and immunogenicity of influenza vaccine in children with asthma in Latin America. Furthermore, it is unclear if influenza vaccination may cause asthma exacerbations. We conducted a placebo-controlled trial to investigate the safety and immunogenicity of an inactivated trivalent split virus influenza vaccine in children with asthma in Mexico. We also measured the impact of influenza vaccination on pulmonary function tests in this population. The inactivated influenza vaccine was immunogenic and safe in terms of local and systemic side effects compared to placebo. We observed no significant impact on pulmonary function tests among vaccine recipients. Given the significant morbidity associated with influenza in children, strategies to promote increased influenza vaccination coverage in this high-risk group in Latin America and elsewhere are urgently needed.
Reversible obstructive sleep apnea caused by occupational exposure to guar gum dust.
Leznoff, A; Haight, J S; Hoffstein, V
1986-05-01
This report describes a case of reversible obstructive sleep apnea caused by occupational exposure to an inhaled allergen, guar gum powder. The patient, a pet food plant employee, also experienced severe cough, rhinitis, and conjunctivitis. Skin tests confirmed the specific guar allergy. Pharyngeal cross-sectional area was smaller than normal. Pulmonary function studies, histamine challenge tests, nasal air-flow resistance measurements, and nocturnal polysomnography were performed on 3 separate occasions: while the patient was working at his usual occupation, at the end of a 3-wk holiday, and after a guar dust challenge in an inhalation chamber. Pulmonary function and histamine challenge tests were consistently normal. At the time of the initial tests, nasal resistance was elevated, and nocturnal polysomnography revealed obstructive sleep apnea. After absence from work, obstructive sleep apnea resolved, and the nasal resistance returned to normal. After challenge with guar gum dust, the patient developed increased resistance to nasal air flow, and obstructive sleep apnea reappeared. This case demonstrates that allergy can cause reversible obstructive sleep apnea and that occupational exposure should be considered in the assessment of patients with this disease.
Abbas, Chiara; Singer, Florian; Yammine, Sophie; Casaulta, Carmen; Latzin, Philipp
2013-12-01
We studied the ability of 4 single-breath gas washout (SBW) tests to measure immediate effects of airway clearance in children with CF. 25 children aged 4-16 years with CF performed pulmonary function tests to assess short-term variability at baseline and response to routine airway clearance. Tidal helium and sulfur hexafluoride (double-tracer gas: DTG) SBW, tidal capnography, tidal and vital capacity nitrogen (N2) SBW and spirometry were applied. We analyzed the gasses' phase III slope (SnIII--normalized for tidal volume) and FEV1 from spirometry. SnIII from tidal DTG-SBW, SnIII from vital capacity N2-SBW, and FEV1 improved significantly after airway clearance. From these tests, individual change of SnIII from tidal DTG-SBW and FEV1 exceeded short-term variability in 10 and 6 children. With the tidal DTG-SBW, an easy and promising test for peripheral gas mixing efficiency, immediate pulmonary function response to airway clearance can be assessed in CF children. Copyright © 2013 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Odler, B; Bikov, A; Streizig, J; Balogh, C; Kiss, E; Vincze, K; Barta, I; Horváth, I; Müller, V
2017-05-01
Biomarkers for pulmonary manifestations in systemic lupus erythematosus (SLE) are missing. Plasma samples of nine SLE patients with known pulmonary involvement (SLE pulm ) and nine SLE patients without pulmonary involvement (SLE) were tested by multiplex microarray analysis for various cyto- and chemokines. Significantly decreased lung function paramters for forced vital capacity (FVC), total lung capacity (TLC), diffusion capacity for carbon monoxide (DL CO ) and diffusion of CO corrected on lung volume (KL CO ) were observed in SLE pulm as compared to SLE patients. CC chemokine ligand 21 (CCL21) and interferon gamma-induced protein 10 (IP-10) levels were significantly higher in SLE pulm , than in patients without pulmonary manifestations. CCL21 correlated negatively with DL CO ( r = -0.73; p < 0.01) and KL CO ( r = -0.62; p < 0.01), while IP-10 with FVC and forced expiratory volume one second. Receiver Operating Characteristics (ROC) analysis confirmed high sensitivity and specificity for the separation of SLE patients with and without pulmonary involvement for the chemokines CCL21 (Area Under Curve (AUC): 0.85; sensitivity%: 88.90; specificity%: 75.00; p < 0.01) and IP-10 (AUC: 0.82; sensitivity%: 66.67, specificity%: 100; p < 0.01). Pleuropulmonary manifestations in SLE patients associated with lung functional and DL CO /KL CO changes and were associated with significant increase in CCL21 and IP-10. These chemokines might serve as potential biomarkers of lung involvement in SLE patients.
Ueda, Kazuhiro; Tanaka, Toshiki; Li, Tao-Sheng; Tanaka, Nobuyuki; Hamano, Kimikazu
2009-03-01
The prediction of pulmonary functional reserve is mandatory in therapeutic decision-making for patients with resectable lung cancer, especially those with underlying lung disease. Volumetric analysis in combination with densitometric analysis of the affected lung lobe or segment with quantitative computed tomography (CT) helps to identify residual pulmonary function, although the utility of this modality needs investigation. The subjects of this prospective study were 30 patients with resectable lung cancer. A three-dimensional CT lung model was created with voxels representing normal lung attenuation (-600 to -910 Hounsfield units). Residual pulmonary function was predicted by drawing a boundary line between the lung to be preserved and that to be resected, directly on the lung model. The predicted values were correlated with the postoperative measured values. The predicted and measured values corresponded well (r=0.89, p<0.001). Although the predicted values corresponded with values predicted by simple calculation using a segment-counting method (r=0.98), there were two outliers whose pulmonary functional reserves were predicted more accurately by CT than by segment counting. The measured pulmonary functional reserves were significantly higher than the predicted values in patients with extensive emphysematous areas (<-910 Hounsfield units), but not in patients with chronic obstructive pulmonary disease. Quantitative CT yielded accurate prediction of functional reserve after lung cancer surgery and helped to identify patients whose functional reserves are likely to be underestimated. Hence, this modality should be utilized for patients with marginal pulmonary function.
Preoperative pulmonary rehabilitation for marginal-function lung cancer patients.
Hashmi, Asra; Baciewicz, Frank A; Soubani, Ayman O; Gadgeel, Shirish M
2017-01-01
Background This study aimed to evaluate the impact of preoperative pulmonary rehabilitation in lung cancer patients undergoing pulmonary resection surgery with marginal lung function. Methods Short-term outcomes of 42 patients with forced expiratory volume in 1 s < 1.6 L who underwent lung resection between 01/2006 and 12/2010 were reviewed retrospectively. They were divided into group A (no preoperative pulmonary rehabilitation) and group B (receiving pulmonary rehabilitation). In group B, a second set of pulmonary function tests was obtained. Results There were no significant differences in terms of sex, age, race, pathologic stage, operative procedure, or smoking years. Mean forced expiratory volume in 1 s and diffusing capacity for carbon monoxide in group A was 1.40 ± 0.22 L and 10.28 ± 2.64 g∙dL -1 vs. 1.39 ± 0.13 L and 10.75 ± 2.08 g∙dL -1 in group B. Group B showed significant improvement in forced expiratory volume in 1 s from 1.39 ± 0.13 to 1.55 ± 0.06 L ( p = 0.02). Mean intensive care unit stay was 6 ± 5 days in group A vs. 9 ± 9 days in group B ( p = 0.22). Mean hospital stay was 10 ± 4 days in group A vs. 14 ± 9 days in group B ( p = 0.31). There was no significant difference in morbidity or mortality between groups. Conclusion Preoperative pulmonary rehabilitation can significantly improve forced expiratory volume in 1 s in some marginal patients undergoing lung cancer resection. However, it does not improve length of stay, morbidity, or mortality.
Study of spirometry in children from Mexico City
DOE Office of Scientific and Technical Information (OSTI.GOV)
Namihira, D.; Strope, G.L.; Helms, R.W.
1986-11-01
A study was conducted in two elementary schools in Mexico City to determine values for pulmonary function tests in school-aged residents of Mexico City. The schools were located in Xalostoc, a highly industrialized area of Mexico City, and San Lorenzo, a suburban area of the city. Although data regarding atmospheric pollution were not available, there is an acknowledged higher level of macroenvironmental air pollution in Xalostoc. Pulmonary function tests were performed on 468 children in San Lorenzo and 405 children in Xalostoc. No differences between residents of the two communities for acute or chronic respiratory conditions were detected by questionnaire.more » The pulmonary function data demonstrate that boys have larger forced vital capacities (FVC) and forced expiratory flows over the middle half of the FVC (FEF25-75) than girls. Slopes of regression lines for FVC but not for FEF25-75 are greater in boys and girls from Xalostoc than in boys and girls from San Lorenzo. This suggests that young children from Xalostoc may experience ill effects of air pollution but develop catch-up growth later. There were no important community or gender effects on slopes of regression lines for height and weight on age. In general, the regression lines for FVC and FEF25-75 were below regression lines reported for children of Mexican ancestry living at sea level.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stanic, Sinisa, E-mail: sinisa.stanic@carle.com; Paulus, Rebecca; Timmerman, Robert D.
2014-04-01
Purpose: To investigate pulmonary function test (PFT) results and arterial blood gas changes (complete PFT) following stereotactic body radiation therapy (SBRT) and to see whether baseline PFT correlates with lung toxicity and overall survival in medically inoperable patients receiving SBRT for early stage, peripheral, non-small cell lung cancer (NSCLC). Methods and Materials: During the 2-year follow-up, PFT data were collected for patients with T1-T2N0M0 peripheral NSCLC who received effectively 18 Gy × 3 in a phase 2 North American multicenter study (Radiation Therapy Oncology Group [RTOG] protocol 0236). Pulmonary toxicity was graded by using the RTOG SBRT pulmonary toxicity scale. Paired Wilcoxon signedmore » rank test, logistic regression model, and Kaplan-Meier method were used for statistical analysis. Results: At 2 years, mean percentage predicted forced expiratory volume in the first second and diffusing capacity for carbon monoxide declines were 5.8% and 6.3%, respectively, with minimal changes in arterial blood gases and no significant decline in oxygen saturation. Baseline PFT was not predictive of any pulmonary toxicity following SBRT. Whole-lung V5 (the percentage of normal lung tissue receiving 5 Gy), V10, V20, and mean dose to the whole lung were almost identical between patients who developed pneumonitis and patients who were pneumonitis-free. Poor baseline PFT did not predict decreased overall survival. Patients with poor baseline PFT as the reason for medical inoperability had higher median and overall survival rates than patients with normal baseline PFT values but with cardiac morbidity. Conclusions: Poor baseline PFT did not appear to predict pulmonary toxicity or decreased overall survival after SBRT in this medically inoperable population. Poor baseline PFT alone should not be used to exclude patients with early stage lung cancer from treatment with SBRT.« less
Clinical, Bronchographic, Radiological, and Physiological Observations in Ten Cases of Asbestosis
Leathart, G. L.
1960-01-01
Ten cases of asbestosis (eight male, two female), aged 45-65 years have been kept under observation for periods of up to eight years. Bronchiectasis was demonstrated bronchographically in six cases. Clubbing of the fingers and coarse crepitations appeared to be signs of bronchiectasis rather than of uncomplicated asbestosis. It is suggested that the prevalence of bronchiectasis is higher than has been reported previously because the patients survived longer. The radiological findings are tabulated and compared with previous descriptions. In these subjects there was no relationship between radiological and clinical state. Nine patients eventually showed clinical deterioration and it often proceeded rapidly. The radiograph however, usually remained unaltered. Pulmonary function tests, including diffusing capacity, arterial blood analysis and estimation of mechanical properties of the lung, were carried out in these 10 cases, and in 11 asbestos workers (aged 35-64 years) without radiological abnormality. The steady state diffusing capacity for carbon monoxide (Dco) at rest was lower in asbestosis than in the control subjects. The pulmonary compliance was remarkably low in asbestosis and related fairly closely to the vital capacity. The maximum voluntary ventilation was also low and was related to increased pulmonary resistance but it cannot be said whether this is in the airways or in the lung tissue. Indirect evidence of inequalities of ventilation/perfusion ratio was obtained in most cases. There is no convincing evidence that pulmonary fibrosis occurs without radiological abnormality, but a defect of diffusion may occur. There is no test of pulmonary function which is diagnostic, but a low pulmonary compliance, especially if combined with a low diffusing capacity, is confirmatory. It is suggested that the demonstration of a progressive decline in vital capacity, or in diffusing capacity, may enable a diagnosis of asbestosis to be made before radiological abnormality has appeared, but this point has not been proved.
Tracy, T F; Bailey, P V; Sadiq, F; Noguchi, A; Silen, M L; Weber, T R
1994-02-01
To improve the survival of newborns with congenital diaphragmatic hernia (CHD), preoperative stabilization with conventional ventilatory therapy and extracorporeal membrane oxygenation (ECMO) have been used. Measurements that quantify pulmonary function may allow an accurate assessment of lethal pulmonary hypoplasia and predict outcome. Pulmonary function tests (PFTs) were obtained in 20 infants preoperatively and postoperatively; these included measurements of compliance, dynamic compliance, and tidal volume. Overall survival was 75%. Six surviving infants were initially managed with ventilator therapy alone, followed by repair (group 1). The remaining 14 patients, who were moribund at presentation or whose initial ventilator therapy failed, were placed on ECMO and received repair during bypass; nine survived (group 2), and five died (group 3). Compliance, dynamic compliance, and tidal volume obtained at initial presentation and immediately preoperatively were significantly higher for group 1 as compared with groups 2 and 3. Infants whose initial compliance was greater than 0.25 mL/cm H2O/kg and initial tidal volume was greater than 3.5 mL/kg did not require ECMO. Ultimate improvement in compliance was noted in 5 of 6 patients in group 1, 8 of 8 patients in group 2, and 5 of 5 in group 3. This improvement followed an initial decline in compliance in 9 of 14 survivors, from 15% to 76%. All six patients in group 1 had tidal volumes of more than 4 mL/kg, as did 7 of 9 patients in group 2. Only one patient among the ECMO nonsurvivors (group 3) had a postoperative tidal volume of this magnitude. These data suggest that initial PFTs may predict which infants will require ECMO.(ABSTRACT TRUNCATED AT 250 WORDS)
Ganesan, Nidhya; Ambroise, Marie Moses; Ramdas, Anita; Kisku, King Herald; Singh, Kulwant; Varghese, Renu G' Boy
2015-06-01
Pulmonary alveolar microlithiasis is a rare disease characterized by intra-alveolar presence of microliths. This study reports an interesting case of pulmonary alveolar microlithiasis and provides a systematic review of cases reported from India. A 23-year-old female presented with a history of cough, wheeze, chest pain, and episodic wheeze for five months. Pulmonary function tests demonstrated an obstructive pattern, and chest Xray showed fine micronodular opacities predominantly involving the middle and lower zones of both lungs. Transbronchial lung biopsy revealed the diagnosis. She responded well to inhaled steroid therapy. A systematic review of literature was performed and identified 73 cases of pulmonary alveolar microlithiasis reported from India. The mean (SD) age of the patients was 28.8 (14.9) years, with an almost equal male:female ratio. Many patients were asymptomatic at presentation. Breathlessness and cough were the most common symptoms, and the disease progressed into respiratory failure associated with cor pulmonale. About one-third of the cases were initially misdiagnosed and treated as pulmonary tuberculosis. Extra-pulmonary manifestations and comorbidities were also evident in our series. This systematic review helps to determine epidemiological and clinical characteristics of pulmonary alveolar microlithiasis. Further research is needed to elucidate the etiopathogenesis, diagnosis, and therapeutic options, which are beneficial in developing and identifying cost-effective treatment for pulmonary alveolar microlithiasis.
21 CFR 868.1900 - Diagnostic pulmonary-function interpretation calculator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Diagnostic pulmonary-function interpretation calculator. 868.1900 Section 868.1900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... pulmonary-function values. (b) Classification. Class II (performance standards). ...
21 CFR 868.1900 - Diagnostic pulmonary-function interpretation calculator.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Diagnostic pulmonary-function interpretation calculator. 868.1900 Section 868.1900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... pulmonary-function values. (b) Classification. Class II (performance standards). ...
Long-term sequelae after lung abscess in children - Two tertiary centers' experience.
Wojsyk-Banaszak, I; Krenke, K; Jończyk-Potoczna, K; Ksepko, K; Wielebska, A; Mikoś, M; Bręborowicz, A
2018-05-01
The aim of the study was to describe the epidemiology and clinical characteristic of children hospitalized with pneumonia complicated by lung abscess, as well as to evaluate the long-term sequelae of the disease. A retrospective review of medical records of all patients treated for pulmonary abscess in two tertiary centers was undertaken. Pulmonary function tests and lung ultrasound were performed at a follow-up. During the study period, 5151 children with pneumonia were admitted, and 49 (0.95%) cases were complicated with lung abscess. In 38 (77.5%) patients, lung abscess was treated solely with antibiotics, and in nine cases (16.3%) surgically. In 21 (51.21%) children complete radiological regression was documented. The mean time for radiological abnormalities regression was 84.14 ± 51.57 days, regardless of the treatment mode. Fifteen patients were followed up at 61.6 ± 28.3 months after discharge. Lung ultrasound revealed minor residual abnormalities: pleural thickening, subpleural consolidations and line B artefacts in 11 (73.3%) children. Pulmonary function tests results were abnormal in eight (53.3%) patients, the most frequent abnormality being hyperinflation. We did not find a restrictive disorder in any of the children. There were no deaths in our study. Lung abscess is a rare but severe complication of pneumonia in children. Most children recover uneventfully with no significant long-term pulmonary sequelae. Copyright © 2018 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Dias, Fernanda Dultra; Sampaio, Luciana Maria Malosá; da Silva, Graziela Alves; Gomes, Évelim LF Dantas; do Nascimento, Eloisa Sanches Pereira; Alves, Vera Lucia Santos; Stirbulov, Roberto; Costa, Dirceu
2013-01-01
Introduction Pulmonary rehabilitation (PR) is a multidisciplinary program of care for patients with chronic obstructive pulmonary disease (COPD) with the goal of improving the functional capacity and quality of life, as well as maintaining the clinical stability of COPD sufferers. However, not all patients are available for such a program despite discomfort with their condition. The aim of this study was to evaluate the effects of a home-based PR (HBPR) program on functional ability, quality of life, and respiratory muscle strength and endurance. Patients and methods Patients with COPD according to the Global Initiative of Chronic Obstructive Lung Disease were randomized (double-blind) into two groups. One group performed a protocol at home with aerobic and muscle strength exercises and was called the intervention group; the other group received only instructions to perform breathing and stretching exercises, characterizing it as the control group (CG). We assessed the following variables at baseline and 2 months: exercise tolerance (incremental shuttle walk test and upper limb test), respiratory muscle (strength and endurance test), and health-related quality of life (Airways Questionnaire 20). Results There were no significant changes after the intervention in either of the two groups in exercise tolerance and quality of life. However, the intervention group had improved respiratory endurance compared with the CG, while the CG presented a decrease in the load sustained by the respiratory muscles after the HBPR. Conclusion A program of HBPR with biweekly supervision (although not enough to provide significant improvements in physical capacity or quality of life) played an important role in maintaining the stability of the clinical features of patients with COPD; the patients had no worsening of symptoms during the intervention period according to the daily log. PMID:24235824
Zhang, Yong-xing; Wei, Qing-yu; Wang, Juan; Qiao, Ting-hui; Bai, Hong-bing; Cai, Li-na
2007-06-01
To explore the damage of respiratory system in the traffic policemen induced by automobile tyre colloidal particle and its allergenicity. The respiratory system symptoms in 445 traffic policemen working outside their offices and 243 controls were investigated and their pulmonary ventilation function index such as FVC, FEV(1.0), MMF and V(50) were determined. The specific IgE antibody of automobile tyre colloidal particle of their serum was determined and the skin-prick test of automobile tyre colloidal particle antigen was performed. Sixty-six traffic policemen working outside their offices and 5 controls with the positive of IgE antibody among them were detected by nasal mucosa provocation test. Sixty-six traffic policemen working outside their offices with the positive of IgE antibody were determined by Terbutaline inhalation test. The positive rate of respiratory system symptoms of traffic policemen such as cough, stethocatharsis, short breath, nasal obstruction, sneeze and nose running was 38.02%, 27.03%, 20.00%, 23.08%, 27.47%, 32.09% and 34.95% respectively and significantly higher than those of the control with significant difference (P < 0.01) or (P < 0.05). The positive rate of specific IgE antibody of automobile tyre colloidal particle, skin- prick test and nasal mucosa provocation test was 14.51%, 23.73% and 54.55% respectively with significant difference (P < 0.01) and (P < 0.05). The percentage, the actual figure compared with the prediction figure, of the index of pulmonary ventilation function (FVC, FEV(1.0) MMF and V(50)) of traffic policemen were significantly lower than those of the control. Terbutaline inhalation test in 66 positive subjects of specific IgE antibody of automobile tyre colloidal particle was positive in 44 subjects, accounting for 9.67% in all policemen investigated. The automobile tyre colloidal particle is one of etiological factors that induce pulmonary ventilation function damage and could result in allergic asthma of traffic police.
Richter, Manuel J.; Grimminger, Jan; Krüger, Britta; Ghofrani, Hossein A.; Mooren, Frank C.; Gall, Henning; Pilat, Christian; Krüger, Karsten
2017-01-01
Pulmonary hypertension (PH) is characterized by severe exercise limitation mainly attributed to the impairment of right ventricular function resulting from a concomitant elevation of pulmonary vascular resistance and pressure. The unquestioned cornerstone in the management of patients with pulmonary arterial hypertension (PAH) is specific vasoactive medical therapy to improve pulmonary hemodynamics and strengthen right ventricular function. Nevertheless, evidence for a beneficial effect of exercise training (ET) on pulmonary hemodynamics and functional capacity in patients with PH has been growing during the past decade. Beneficial effects of ET on regulating factors, inflammation, and metabolism have also been described. Small case-control studies and randomized clinical trials in larger populations of patients with PH demonstrated substantial improvements in functional capacity after ET. These findings were accompanied by several studies that suggested an effect of ET on inflammation, although a direct link between this effect and the therapeutic benefit of ET in PH has not yet been demonstrated. On this background, the aim of the present review is to describe current concepts regarding the effects of exercise on the pulmonary circulation and pathophysiological limitations, as well as the clinical and mechanistic effects of exercise in patients with PH. PMID:28680563
Muscular Oxygen Uptake Kinetics in Aged Adults.
Koschate, J; Drescher, U; Baum, K; Eichberg, S; Schiffer, T; Latsch, J; Brixius, K; Hoffmann, U
2016-06-01
Pulmonary oxygen uptake (V˙O2) kinetics and heart rate kinetics are influenced by age and fitness. Muscular V˙O2 kinetics can be estimated from heart rate and pulmonary V˙O2. In this study the applicability of a test using pseudo-random binary sequences in combination with a model to estimate muscular V˙O2 kinetics was tested. Muscular V˙O2 kinetics were expected to be faster than pulmonary V˙O2 kinetics, slowed in aged subjects and correlated with maximum V˙O2 and heart rate kinetics. 27 elderly subjects (73±3 years; 81.1±8.2 kg; 175±4.7 cm) participated. Cardiorespiratory kinetics were assessed using the maximum of cross-correlation functions, higher maxima implying faster kinetics. Muscular V˙O2 kinetics were faster than pulmonary V˙O2 kinetics (0.31±0.1 vs. 0.29±0.1 s; p=0.004). Heart rate kinetics were not correlated with muscular or pulmonary V˙O2 kinetics or maximum V˙O2. Muscular V˙O2 kinetics correlated with maximum V˙O2 (r=0.35; p=0.033). This suggests, that muscular V˙O2 kinetics are faster than estimates from pulmonary V˙O2 and related to maximum V˙O2 in aged subjects. In the future this experimental approach may help to characterize alterations in muscular V˙O2 under various conditions independent of motivation and maximal effort. © Georg Thieme Verlag KG Stuttgart · New York.
Ito, Eiki; Murata, Akira; Yamamoto, Kazuo; Kudo, Shoji
2003-04-01
We evaluated body weight loss and growth hormone secretion in patients with sleep-disordered breathing associated with chronic obstructive pulmonary disease. Of 11 patients hospitalized for pulmonary rehabilitation, five (WL group) had a history of body weight loss within two years before their interviews, while the other 6 patients (NWL group) had no changes in body weight. All patients underwent body index measurements, pulmonary function tests, blood gas analyses, assessments of nutritional status, and full night polysomnography for two consecutive days. Growth hormone levels were measured in the first 3-hour period following falling asleep. There were no significant inter-group differences between the results of pulmonary function tests, blood gas analyses, or nutritional status assessment. The WL group had a significantly higher percentage loss of body weight than the NWL group (mean +/- S.D. 11.5 +/- 4.7% in the WL group versus 2.7 +/- 1.8% in the NWL group, p < 0.01). The WL group had a significantly higher sleep apnea/hypopnea index than the NWL group (42.4 +/- 9.5/hr in the WL group versus 7.8 +/- 2.9/hr in the NWL group, p < 0.01). The WL group showed a higher rate of stage I + II sleep than the NWL group (84.9 +/- 7.0% versus 64.5 +/- 8.7%), with lower rates of slow wave sleep (2.2 +/- 2.1% versus 15.0 +/- 8.7%) and rapid eye movement sleep (12.9 +/- 6.3% versus 20.6 +/- 1.0%). The WL group showed a low level of growth hormone secretion with no peak in the sequential curve, but had a higher level of insulin growth factor-1 than the NWL group (148 +/- 36 ng/ml versus 90 +/- 22 ng/ml, p < 0.01). These results suggest that chronic obstructive pulmonary disease patients undergoing weight loss are likely to have an increase of growth hormone secretions in the daytime, possibly induced by underlying psychiatric disorders such as depression. Patients with chronic obstructive pulmonary disease may lose weight regardless of nutritional status because of a disturbance of growth hormone secretion resulting of sleep-disordered breathing.
Intraabdominal pressure after full abdominoplasty in obese multiparous patients.
Al-Basti, Habib B; El-Khatib, Hamdy A; Taha, Ahmed; Sattar, Hisham Abdul; Bener, Abdulbari
2004-06-01
This study measured intraabdominal pressure in morbidly obese and multiparous patients who underwent abdominoplasty with musculoaponeurotic plication. The purpose of this study was to evaluate any potential adverse effect on pulmonary function by virtue of pulmonary function tests and measurement of peak airway pressure. The study included 43 multiparous, morbidly obese women (mean body mass index, 35.8 kg/m2) with a mean age (+/- SD) of 38.6 +/- 7 years. All had full abdominoplasty and repair of the musculoaponeurotic system during the period from June of 1999 to May of 2002. Forty-three morbidly obese multiparous patients were seen over a period of 24 months. Their intraabdominal pressure was estimated by measuring the intravesical pressure before and after repair of severe diastases (divarication) of the rectus abdominis muscles with severely flaccid myofascial component before using a hydrometer connected to a Foley catheter both before and after repair. All patients had pulmonary function checked before and 2 months after the repair. The study confirmed that there are minimal changes on the intraabdominal pressure parameters compared with measurement before and after full abdominoplasty with plication of the rectus muscles, with minimal to negligible changes in the intrathoracic pressure. These changes are clinically and statistically significant (p < 0.0001). The study also recommended the safety of full abdominoplasty and repair of the musculoaponeurotic system in multiparous and morbidly obese patients. Furthermore, no statistically significant difference was found in pulmonary function parameters before and after surgery in patients with a history of bronchial asthma.
Fourier-based linear systems description of free-breathing pulmonary magnetic resonance imaging
NASA Astrophysics Data System (ADS)
Capaldi, D. P. I.; Svenningsen, S.; Cunningham, I. A.; Parraga, G.
2015-03-01
Fourier-decomposition of free-breathing pulmonary magnetic resonance imaging (FDMRI) was recently piloted as a way to provide rapid quantitative pulmonary maps of ventilation and perfusion without the use of exogenous contrast agents. This method exploits fast pulmonary MRI acquisition of free-breathing proton (1H) pulmonary images and non-rigid registration to compensate for changes in position and shape of the thorax associated with breathing. In this way, ventilation imaging using conventional MRI systems can be undertaken but there has been no systematic evaluation of fundamental image quality measurements based on linear systems theory. We investigated the performance of free-breathing pulmonary ventilation imaging using a Fourier-based linear system description of each operation required to generate FDMRI ventilation maps. Twelve subjects with chronic obstructive pulmonary disease (COPD) or bronchiectasis underwent pulmonary function tests and MRI. Non-rigid registration was used to co-register the temporal series of pulmonary images. Pulmonary voxel intensities were aligned along a time axis and discrete Fourier transforms were performed on the periodic signal intensity pattern to generate frequency spectra. We determined the signal-to-noise ratio (SNR) of the FDMRI ventilation maps using a conventional approach (SNRC) and using the Fourier-based description (SNRF). Mean SNR was 4.7 ± 1.3 for subjects with bronchiectasis and 3.4 ± 1.8, for COPD subjects (p>.05). SNRF was significantly different than SNRC (p<.01). SNRF was approximately 50% of SNRC suggesting that the linear system model well-estimates the current approach.
Can patients with pulmonary hypertension travel to high altitude?
Luks, Andrew M
2009-01-01
With the increasing popularity of adventure travel and mountain activities, it is likely that many high altitude travelers will have underlying medical problems and approach clinicians for advice about ensuring a safe sojourn. Patients with underlying pulmonary hypertension are one group who warrants significant concern during high altitude travel, because ambient hypoxia at high altitude will trigger hypoxic pulmonary vasoconstriction and cause further increases in pulmonary artery (PA) pressure, which may worsen hemodynamics and also predispose to acute altitude illness. After addressing basic information about pulmonary hypertension and pulmonary vascular responses to acute hypoxia, this review discusses the evidence supporting an increased risk for high altitude pulmonary edema in these patients, concerns regarding worsening oxygenation and right-heart function, the degree of underlying pulmonary hypertension necessary to increase risk, and the altitude at which such problems may occur. These patients may be able to travel to high altitude, but they require careful pre-trip assessment, including echocardiography and, when feasible, high altitude simulation testing with echocardiography to assess changes in PA pressure and oxygenation under hypoxic conditions. Those with mean PA pressure > or =35 mm Hg or systolic PA pressure > or =50 mm Hg at baseline should avoid travel to >2000 m; but if such travel is necessary or strongly desired, they should use supplemental oxygen during the sojourn. Patients with milder degrees of pulmonary hypertension may travel to altitudes <3000 m, but should consider prophylactic measures, including pulmonary vasodilators or supplemental oxygen.
Rybacka, Anna; Goździk-Spychalska, Joanna; Rybacki, Adam; Piorunek, Tomasz; Batura-Gabryel, Halina; Karmelita-Katulska, Katarzyna
2018-05-04
In cystic fibrosis, pulmonary function tests (PFTs) and computed tomography are used to assess lung function and structure, respectively. Although both techniques of assessment are congruent there are lingering doubts about which PFTs variables show the best congruence with computed tomography scoring. In this study we addressed the issue by reinvestigating the association between PFTs variables and the score of changes seen in computed tomography scans in patients with cystic fibrosis with and without pulmonary exacerbation. This retrospective study comprised 40 patients in whom PFTs and computed tomography were performed no longer than 3 weeks apart. Images (inspiratory: 0.625 mm slice thickness, 0.625 mm interval; expiratory: 1.250 mm slice thickness, 10 mm interval) were evaluated with the Bhalla scoring system. The most frequent structural abnormality found in scans were bronchiectases and peribronchial thickening. The strongest relationship was found between the Bhalla sore and forced expiratory volume in 1 s (FEV1). The Bhalla sore also was related to forced vital capacity (FVC), FEV1/FVC ratio, residual volume (RV), and RV/total lung capacity (TLC) ratio. We conclude that lung structural data obtained from the computed tomography examination are highly congruent to lung function data. Thus, computed tomography imaging may supersede functional assessment in cases of poor compliance with spirometry procedures in the lederly or children. Computed tomography also seems more sensitive than PFTs in the assessment of cystic fibrosis progression. Moreover, in early phases of cystic fibrosis, computed tomography, due to its excellent resolution, may be irreplaceable in monitoring pulmonary damage.
Vorrink, Sigrid N W; Kort, Helianthe S M; Troosters, Thierry; Zanen, Pieter; Lammers, Jan-Willem J
2016-10-01
Physical inactivity in patients with chronic obstructive pulmonary disease (COPD) is associated with poor health status and increased disease burden. The present study aims to test the efficacy of a previously developed mobile (m)Health intervention to improve or maintain physical activity in patients with COPD after pulmonary rehabilitation.A randomised controlled trial was performed in 32 physiotherapy practices in the Netherlands. COPD patients were randomised into intervention or usual care groups. The intervention consisted of a smartphone application for the patients and a monitoring website for the physiotherapists. Measurements were performed at 0, 3, 6 and 12 months. Physical activity, functional exercise capacity, lung function, health-related quality of life and body mass index were assessed.157 patients started the study and 121 completed it. There were no significant positive effects of the intervention on physical activity (at 0 months: intervention 5824±3418 steps per weekday, usual care 5717±2870 steps per weekday; at 12 months: intervention 4819±2526 steps per weekday, usual care 4950±2634 steps per weekday; p=0.811) or on the secondary end-points. There was a significant decrease over time in physical activity (p<0.001), lung function (p<0.001) and mastery (p=0.017), but not in functional exercise capacity (p=0.585).Although functional exercise capacity did not deteriorate, our mHealth intervention did not improve or maintain physical activity in patients with COPD after a period of pulmonary rehabilitation. Copyright ©ERS 2016.
Park, Robert M; Gilbert, Stephen J
2018-06-01
The butter flavoring additive, diacetyl (DA), can cause bronchiolitis obliterans (BO) by inhalation. A risk assessment was performed using data from a microwave popcorn manufacturing plant. Current employees' medical history and pulmonary function tests together with air sampling over a 2.7-year period were used to analyze forced expiratory volume in 1 second (FEV1) and FEV1/forced vital capacity (FVC). The exposure responses for declining pulmonary function and for possible early onset of BO were estimated using multiple regression methods. Several exposure metrics were investigated; benchmark dose and excess lifetime risk of impairment were calculated. Forty-six percent of the population had less than 6 months exposure to DA. Percent-of-predicted FEV1 declined with cumulative exposure (0.40 per ppm-yr, P < 10) as did percent FEV1/FVC (0.13 per ppm-yr, P = 0.0004). Lifetime respiratory impairment prevalence of one per thousand resulted from 0.005 ppm DA and one per thousand lifetime incidence of impairment was predicted for 0.002 ppm DA. DA exposures, often exceeding 1 ppm in the past, place workers at high risk of pulmonary impairment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hollinger, W.M.; Staton, G.W. Jr.; Fajman, W.A.
1985-07-01
To find a pretreatment predictor of steroid responsiveness in pulmonary sarcoidosis the authors studied 21 patients before and after steroid treatment by clinical evaluation, pulmonary function tests, bronchoalveolar lavage (BAL), gallium-67 lung scan, and serum angiotensin-converting enzyme (SACE) level. Although clinical score, forced vital capacity (FVC), BAL percent lymphocytes (% lymphs), quantitated gallium-67 lung uptake, and SACE levels all improved with therapy, only the pretreatment BAL % lymphs correlated with the improvement in FVC (r = 0.47, p less than 0.05). Pretreatment BAL % lymphs of greater than or equal to 35% predicted improvement in FVC of 10/11 patients, whereasmore » among 10 patients with BAL % lymphs less than 35%, 5 patients improved and 5 deteriorated. Clinical score, pulmonary function parameters, quantitated gallium-67 lung uptake, and SACE level used alone, in combination with BAL % lymphs or in combination with each other, did not improve this predictive value. The authors conclude that steroid therapy improves a number of clinical and laboratory parameters in sarcoidosis, but only the pretreatment BAL % lymphs are useful in predicting therapeutic responsiveness.« less
Bronchiectasis: correlation of high-resolution CT findings with health-related quality of life.
Eshed, I; Minski, I; Katz, R; Jones, P W; Priel, I E
2007-02-01
To evaluate the relationship between the severity of bronchiectatic diseases, as evident on high-resolution computed tomography (HRCT) and the patient's quality of life measured using the St George's Respiratory Questionnaire (SGRQ). Forty-six patients (25 women, 21 men, mean age: 63 years) with bronchiectatic disease as evident on recent HRCT examinations were recruited. Each patient completed the SGRQ and underwent respiratory function tests. HRCT findings were blindly and independently scored by two radiologists, using the modified Bhalla scoring system. The relationships between HRCT scores, SGRQ scores and pulmonary function tests were evaluated. The patients' total CT score did not correlate with the SGRQ scores. However, patients with more advanced disease on HRCT, significantly differed in their SGRQ scores from patients with milder bronchiectatic disease. A significant correlation was found between the CT scores for the middle and distal lung zones and the activity, impacts and total SGRQ scores. No correlation was found between CT scores and respiratory function test indices. However, a significant correlation was found between the SGRQ scores and most of the respiratory function test indices. A correlation between the severity of bronchiectatic disease as expressed in HRCT and the health-related quality of life exists in patients with a more severe bronchiectatic disease but not in patients with mild disease. Such correlation depends on the location of the bronchiectasis in the pulmonary tree.
[Changes in respiratory function tests of healthy miners in accordance with length of service].
Shishkin, G S; Ustiuzhaninova, N V; Krasulina, G P
2010-01-01
The study covered respiratory function tests in healthy miners with variable length of service. Findings are that the first year of mining is characterized by slower interchange of gases in respiratory parts of lungs, by induced protective reaction that increases dilution of inspired air. The years from second to fifth demonstrate stabilized changes and external respiratory system fixed in new functional state kept over next 15-18 years. After 20 years of service in mine, the external respiration system becomes overstrained with intensified compensatory pulmonary ventilation and protective reaction.
Pulmonary symptoms and diagnoses are associated with HIV in the MACS and WIHS cohorts
2014-01-01
Background Several lung diseases are increasingly recognized as comorbidities with HIV; however, few data exist related to the spectrum of respiratory symptoms, diagnostic testing, and diagnoses in the current HIV era. The objective of the study is to determine the impact of HIV on prevalence and incidence of respiratory disease in the current era of effective antiretroviral treatment. Methods A pulmonary-specific questionnaire was administered yearly for three years to participants in the Multicenter AIDS Cohort Study (MACS) and Women’s Interagency HIV Study (WIHS). Adjusted prevalence ratios for respiratory symptoms, testing, or diagnoses and adjusted incidence rate ratios for diagnoses in HIV-infected compared to HIV-uninfected participants were determined. Risk factors for outcomes in HIV-infected individuals were modeled. Results Baseline pulmonary questionnaires were completed by 907 HIV-infected and 989 HIV-uninfected participants in the MACS cohort and by 1405 HIV-infected and 571 HIV-uninfected participants in the WIHS cohort. In MACS, dyspnea, cough, wheezing, sleep apnea, and incident chronic obstructive pulmonary disease (COPD) were more common in HIV-infected participants. In WIHS, wheezing and sleep apnea were more common in HIV-infected participants. Smoking (MACS and WIHS) and greater body mass index (WIHS) were associated with more respiratory symptoms and diagnoses. While sputum studies, bronchoscopies, and chest computed tomography scans were more likely to be performed in HIV-infected participants, pulmonary function tests were no more common in HIV-infected individuals. Respiratory symptoms in HIV-infected individuals were associated with history of pneumonia, cardiovascular disease, or use of HAART. A diagnosis of asthma or COPD was associated with previous pneumonia. Conclusions In these two cohorts, HIV is an independent risk factor for several respiratory symptoms and pulmonary diseases including COPD and sleep apnea. Despite a higher prevalence of chronic respiratory symptoms, testing for non-infectious respiratory diseases may be underutilized in the HIV-infected population. PMID:24884738
Pulmonary symptoms and diagnoses are associated with HIV in the MACS and WIHS cohorts.
Gingo, Matthew R; Balasubramani, Goundappa K; Rice, Thomas B; Kingsley, Lawrence; Kleerup, Eric C; Detels, Roger; Seaberg, Eric C; Greenblatt, Ruth M; Holman, Susan; Huang, Laurence; Sutton, Sarah H; Bertolet, Marnie; Morris, Alison
2014-04-30
Several lung diseases are increasingly recognized as comorbidities with HIV; however, few data exist related to the spectrum of respiratory symptoms, diagnostic testing, and diagnoses in the current HIV era. The objective of the study is to determine the impact of HIV on prevalence and incidence of respiratory disease in the current era of effective antiretroviral treatment. A pulmonary-specific questionnaire was administered yearly for three years to participants in the Multicenter AIDS Cohort Study (MACS) and Women's Interagency HIV Study (WIHS). Adjusted prevalence ratios for respiratory symptoms, testing, or diagnoses and adjusted incidence rate ratios for diagnoses in HIV-infected compared to HIV-uninfected participants were determined. Risk factors for outcomes in HIV-infected individuals were modeled. Baseline pulmonary questionnaires were completed by 907 HIV-infected and 989 HIV-uninfected participants in the MACS cohort and by 1405 HIV-infected and 571 HIV-uninfected participants in the WIHS cohort. In MACS, dyspnea, cough, wheezing, sleep apnea, and incident chronic obstructive pulmonary disease (COPD) were more common in HIV-infected participants. In WIHS, wheezing and sleep apnea were more common in HIV-infected participants. Smoking (MACS and WIHS) and greater body mass index (WIHS) were associated with more respiratory symptoms and diagnoses. While sputum studies, bronchoscopies, and chest computed tomography scans were more likely to be performed in HIV-infected participants, pulmonary function tests were no more common in HIV-infected individuals. Respiratory symptoms in HIV-infected individuals were associated with history of pneumonia, cardiovascular disease, or use of HAART. A diagnosis of asthma or COPD was associated with previous pneumonia. In these two cohorts, HIV is an independent risk factor for several respiratory symptoms and pulmonary diseases including COPD and sleep apnea. Despite a higher prevalence of chronic respiratory symptoms, testing for non-infectious respiratory diseases may be underutilized in the HIV-infected population.
Right Ventricular Longitudinal Strain Is Depressed in a Bovine Model of Pulmonary Hypertension.
Bartels, Karsten; Brown, R Dale; Fox, Daniel L; Bull, Todd M; Neary, Joseph M; Dorosz, Jennifer L; Fonseca, Brian M; Stenmark, Kurt R
2016-05-01
Pulmonary hypertension and resulting right ventricular (RV) dysfunction are associated with significant perioperative morbidity and mortality. Although echocardiography permits real-time, noninvasive assessment of RV function, objective and comparative measures are underdeveloped, and appropriate animal models to study their utility are lacking. Longitudinal strain analysis is a novel echocardiographic method to quantify RV performance. Herein, we hypothesized that peak RV longitudinal strain would worsen in a bovine model of pulmonary hypertension compared with control animals. Newborn Holstein calves were randomly chosen for induction of pulmonary hypertension versus control conditions. Pulmonary hypertension was induced by exposing animals to 14 days of hypoxia (equivalent to 4570 m above sea level or 430 mm Hg barometric pressure). Control animals were kept at ambient pressure/normoxia. At the end of the intervention, transthoracic echocardiography was performed in awake calves. Longitudinal wall strain was analyzed from modified apical 4-chamber views focused on the RV. Comparisons between measurements in hypoxic versus nonhypoxic conditions were performed using Student t test for independent samples and unequal variances. After 14 days at normoxic versus hypoxic conditions, 15 calves were examined with echocardiography. Pulmonary hypertension was confirmed by right heart catheterization and associated with reduced RV systolic function. Mean systolic strain measurements were compared in normoxia-exposed animals (n = 8) and hypoxia-exposed animals (n = 7). Peak global systolic longitudinal RV strain after hypoxia worsened compared to normoxia (-10.5% vs -16.1%, P = 0.0031). Peak RV free wall strain also worsened after hypoxia compared to normoxia (-9.6% vs -17.3%, P = 0.0031). Findings from strain analysis were confirmed by measurement of tricuspid annular peak systolic excursion. Peak longitudinal RV strain detected worsened RV function in animals with hypoxia-induced pulmonary hypertension compared with control animals. This relationship was demonstrated in the transthoracic echocardiographic 4-chamber view independently for the RV free wall and for the combination of the free and septal walls. This innovative model of bovine pulmonary hypertension may prove useful to compare different monitoring technologies for the assessment of early events of RV dysfunction. Further studies linking novel RV imaging applications with mechanistic and therapeutic approaches are needed.
Arcadu, Antonella; Byrne, Suzanne C; Pirina, Pietro; Hartman, Thomas E; Bartholmai, Brian J; Moua, Teng
2017-08-01
Little is known about presenting 'inconsistent' or 'possible' usual interstitial pneumonia (UIP) computed tomography (CT) patterns advancing to 'consistent' UIP as disease progresses in idiopathic pulmonary fibrosis (IPF). We hypothesized that if 'consistent' UIP represented more advanced disease, such a pattern on presentation should also correlate with more severe pulmonary function test (PFT) abnormalities. Consecutive IPF patients (2005-2013) diagnosed by international criteria with baseline PFT and CT were included. Presenting CTs were assessed by three expert radiologists for consensus UIP pattern ('consistent', 'possible', and 'inconsistent'). Approximation of individual and combined interstitial abnormalities was also performed with correlation of interstitial abnormalities and UIP CT pattern made with PFT findings and survival. Three-hundred and fifty patients (70% male) were included with a mean age of 68.3 years. Mean percent predicted forced vital capacity (FVC%) and diffusion capacity (DLCO%) was 64% and 45.5% respectively. Older age and male gender correlated more with 'consistent' UIP CT pattern. FVC% was not associated with any UIP pattern but did correlate with total volume of radiologist assessed interstitial abnormalities. DLCO% was lower in those with 'consistent' UIP pattern. A 'consistent' UIP CT pattern was also not independently predictive of survival after correction for age, gender, FVC%, and DLCO%. PFT findings appear to correlate with extent of radiologic disease but not specific morphologic patterns. Whether such UIP patterns represent different stages of disease severity or radiologic progression is not supported by coinciding pulmonary function decline. Copyright © 2017 Elsevier Ltd. All rights reserved.
Bellofiore, Alessandro; Chesler, Naomi C
2013-07-01
The right ventricle (RV) is a pulsatile pump, the efficiency of which depends on proper hemodynamic coupling with the compliant pulmonary circulation. The RV and pulmonary circulation exhibit structural and functional differences with the more extensively investigated left ventricle (LV) and systemic circulation. In light of these differences, metrics of LV function and efficiency of coupling to the systemic circulation cannot be used without modification to characterize RV function and efficiency of coupling to the pulmonary circulation. In this article, we review RV physiology and mechanics, established and novel methods for measuring RV function and hemodynamic coupling, and findings from application of these methods to RV function and coupling changes with pulmonary hypertension. We especially focus on non-invasive measurements, as these may represent the future for clinical monitoring of disease progression and the effect of drug therapies.
Obstructive Airways Disease With Air Trapping Among Firefighters Exposed to World Trade Center Dust
Weiden, Michael D.; Ferrier, Natalia; Nolan, Anna; Rom, William N.; Comfort, Ashley; Gustave, Jackson; Zeig-Owens, Rachel; Zheng, Shugi; Goldring, Roberta M.; Berger, Kenneth I.; Cosenza, Kaitlyn; Lee, Roy; Webber, Mayris P.; Kelly, Kerry J.; Aldrich, Thomas K.
2010-01-01
Background: The World Trade Center (WTC) collapse produced a massive exposure to respirable particulates in New York City Fire Department (FDNY) rescue workers. This group had spirometry examinations pre-September 11, 2001, and post-September 11, 2001, demonstrating declines in lung function with parallel declines in FEV1 and FVC. To date, the underlying pathophysiologic cause for this has been open to question. Methods: Of 13,234 participants in the FDNY-WTC Monitoring Program, 1,720 (13%) were referred for pulmonary subspecialty evaluation at a single institution. Evaluation included 919 full pulmonary function tests, 1,219 methacholine challenge tests, and 982 high-resolution chest CT scans. Results: At pulmonary evaluation (median 34 months post-September 11, 2001), median values were FEV1 93% predicted (interquartile range [IQR], 83%-101%), FVC 98% predicted (IQR, 89%-106%), and FEV1/FVC 0.78 (IQR, 0.72-0.82). The residual volume (RV) was 123% predicted (IQR, 106%-147%) with nearly all participants having normal total lung capacity, functional residual capacity, and diffusing capacity of carbon monoxide. Also, 1,051/1,720 (59%) had obstructive airways disease based on at least one of the following: FEV1/FVC, bronchodilator responsiveness, hyperreactivity, or elevated RV. After adjusting for age, gender, race, height and weight, and tobacco use, the decline in FEV1 post-September 11, 2001, was significantly correlated with increased RV percent predicted (P < .0001), increased bronchodilator responsiveness (P < .0001), and increased hyperreactivity (P = .0056). CT scans demonstrated bronchial wall thickening that was significantly associated with the decline in FEV1 post-September 11, 2001 (P = .024), increases in hyperreactivity (P < .0001), and increases in RV (P < .0001). Few had evidence for interstitial disease. Conclusions: Airways obstruction was the predominant physiologic finding underlying the reduction in lung function post-September 11, 2001, in FDNY WTC rescue workers presenting for pulmonary evaluation. PMID:19820077
Salisbury, Margaret L; Xia, Meng; Zhou, Yueren; Murray, Susan; Tayob, Nabihah; Brown, Kevin K; Wells, Athol U; Schmidt, Shelley L; Martinez, Fernando J; Flaherty, Kevin R
2016-02-01
Idiopathic pulmonary fibrosis is a progressive lung disease with variable course. The Gender-Age-Physiology (GAP) Index and staging system uses clinical variables to stage mortality risk. It is unknown whether clinical staging predicts future decline in pulmonary function. We assessed whether the GAP stage predicts future pulmonary function decline and whether interval pulmonary function change predicts mortality after accounting for stage. Patients with idiopathic pulmonary fibrosis (N = 657) were identified retrospectively at three tertiary referral centers, and baseline GAP stages were assessed. Mixed models were used to describe average trajectories of FVC and diffusing capacity of the lung for carbon monoxide (Dlco). Multivariable Cox proportional hazards models were used to assess whether declines in pulmonary function ≥ 10% in 6 months predict mortality after accounting for GAP stage. Over a 2-year period, GAP stage was not associated with differences in yearly lung function decline. After accounting for stage, a 10% decrease in FVC or Dlco over 6 months independently predicted death or transplantation (FVC hazard ratio, 1.37; Dlco hazard ratio, 1.30; both, P ≤ .03). Patients with GAP stage 2 with declining pulmonary function experienced a survival profile similar to patients with GAP stage 3, with 1-year event-free survival of 59.3% (95% CI, 49.4-67.8) vs 56.9% (95% CI, 42.2-69.1). Baseline GAP stage predicted death or lung transplantation but not the rate of future pulmonary function decline. After accounting for GAP stage, a decline of ≥ 10% over 6 months independently predicted death or lung transplantation. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Impact of Intensive Physiotherapy on Cognitive Function after Coronary Artery Bypass Graft Surgery.
Cavalcante, Elder Dos Santos; Magario, Rosmeiri; Conforti, César Augusto; Cipriano Júnior, Gerson; Arena, Ross; Carvalho, Antonio Carlos C; Buffolo, Enio; Luna Filho, Bráulio
2014-11-01
Background: Coronary artery bypass graft (CABG) is a standard surgical option for patients with diffuse and significant arterial plaque. This procedure, however, is not free of postoperative complications, especially pulmonary and cognitive disorders. Objective: This study aimed at comparing the impact of two different physiotherapy treatment approaches on pulmonary and cognitive function of patients undergoing CABG. Methods: Neuropsychological and pulmonary function tests were applied, prior to and following CABG, to 39 patients randomized into two groups as follows: Group 1 (control) - 20 patients underwent one physiotherapy session daily; and Group 2 (intensive physiotherapy) - 19 patients underwent three physiotherapy sessions daily during the recovery phase at the hospital. Non-paired and paired Student t tests were used to compare continuous variables. Variables without normal distribution were compared between groups by using Mann-Whitney test, and, within the same group at different times, by using Wilcoxon test. The chi-square test assessed differences of categorical variables. Statistical tests with a p value ≤ 0.05 were considered significant. Results: Changes in pulmonary function were not significantly different between the groups. However, while Group 2 patients showed no decline in their neurocognitive function, Group 1 patients showed a decline in their cognitive functions (P ≤ 0.01). Conclusion: Those results highlight the importance of physiotherapy after CABG and support the implementation of multiple sessions per day, providing patients with better psychosocial conditions and less morbidity.Fundamento: A cirurgia de revascularização miocárdica (CRM) é a opção cirúrgica padrão para pacientes com placas arteriais difusas e significativas. Tal procedimento, no entanto, não é desprovido de complicações pós-operatórias, especialmente distúrbios pulmonares e cognitivos. Objetivo: Comparar o impacto de duas abordagens fisioterapêuticas diferentes nas funções pulmonar e cognitiva de pacientes submetidos a CRM. Métodos: Testes de função pulmonar e neuropsicológicos foram aplicados, antes e após CRM, a 39 pacientes randomizados em dois grupos: Grupo 1 - 20 pacientes-controle submetidos a uma sessão de fisioterapia por dia; Grupo 2 - 19 pacientes submetidos a três sessões de fisioterapia por dia durante recuperação no hospital. Testes t de Student pareado e não pareado foram usados para comparar as variáveis contínuas. Variáveis sem distribuição normal foram comparadas entre os grupos usando-se o teste de Mann-Whitney, e, dentro do mesmo grupo em momentos diferentes, usando-se o teste de Wilcoxon. O teste do qui-quadrado avaliou diferenças das variáveis categóricas. Testes estatísticos com p valor ≤ 0,05 foram considerados significativos. Resultados: As alterações da função pulmonar não diferiram significativamente entre os grupos. Entretanto, o mesmo não ocorreu com a função neurocognitiva, que apresentou declínio no Grupo 1, mas não no Grupo 2 (p ≤ 0,01). Conclusão: Tais resultados reforçam a importância da fisioterapia após CRM e da realização de múltiplas sessões por dia, o que oferece aos pacientes melhores condições psicossociais e menos morbidade.
Obad, Ante; Palada, Ivan; Valic, Zoran; Ivančev, Vladimir; Baković, Darija; Wisløff, Ulrik; Brubakk, Alf O; Dujić, Željko
2007-01-01
Diving-induced acute alterations in cardiovascular function such as arterial endothelial dysfunction, increased pulmonary artery pressure (PAP) and reduced heart function have been recently reported. We tested the effects of acute antioxidants on arterial endothelial function, PAP and heart function before and after a field dive. Vitamins C (2 g) and E (400 IU) were given to subjects 2 h before a second dive (protocol 1) and in a placebo-controlled crossover study design (protocol 2). Seven experienced divers performed open sea dives to 30 msw with standard decompression in a non-randomized protocol, and six of them participated in a randomized trial. Before and after the dives ventricular volumes and function and pulmonary and brachial artery function were assessed by ultrasound. The control dive resulted in a significant reduction in flow-mediated dilatation (FMD) and heart function with increased mean PAP. Twenty-four hours after the control dive FMD was still reduced 37% below baseline (8.1 versus 5.1%, P = 0.005), while right ventricle ejection fraction (RV-EF), left ventricle EF and endocardial fractional shortening were reduced much less (∼2–3%). At the same time RV end-systolic volume was increased by 9% and mean PAP by 5%. Acute antioxidants significantly attenuated only the reduction in FMD post-dive (P < 0.001), while changes in pulmonary artery and heart function were unaffected by antioxidant ingestion. These findings were confirmed by repeating the experiments in a randomized study design. FMD returned to baseline values 72 h after the dive with pre-dive placebo, whereas for most cardiovascular parameters this occurred earlier (24–48 h). Right ventricular dysfunction and increased PAP lasted longer. Acute antioxidants attenuated arterial endothelial dysfunction after diving, while reduction in heart and pulmonary artery function were unchanged. Cardiovascular changes after diving are not fully reversed up to 3 days after a dive, suggesting longer lasting negative effects. PMID:17110413
Obad, Ante; Palada, Ivan; Valic, Zoran; Ivancev, Vladimir; Baković, Darija; Wisløff, Ulrik; Brubakk, Alf O; Dujić, Zeljko
2007-02-01
Diving-induced acute alterations in cardiovascular function such as arterial endothelial dysfunction, increased pulmonary artery pressure (PAP) and reduced heart function have been recently reported. We tested the effects of acute antioxidants on arterial endothelial function, PAP and heart function before and after a field dive. Vitamins C (2 g) and E (400 IU) were given to subjects 2 h before a second dive (protocol 1) and in a placebo-controlled crossover study design (protocol 2). Seven experienced divers performed open sea dives to 30 msw with standard decompression in a non-randomized protocol, and six of them participated in a randomized trial. Before and after the dives ventricular volumes and function and pulmonary and brachial artery function were assessed by ultrasound. The control dive resulted in a significant reduction in flow-mediated dilatation (FMD) and heart function with increased mean PAP. Twenty-four hours after the control dive FMD was still reduced 37% below baseline (8.1 versus 5.1%, P = 0.005), while right ventricle ejection fraction (RV-EF), left ventricle EF and endocardial fractional shortening were reduced much less (approximately 2-3%). At the same time RV end-systolic volume was increased by 9% and mean PAP by 5%. Acute antioxidants significantly attenuated only the reduction in FMD post-dive (P < 0.001), while changes in pulmonary artery and heart function were unaffected by antioxidant ingestion. These findings were confirmed by repeating the experiments in a randomized study design. FMD returned to baseline values 72 h after the dive with pre-dive placebo, whereas for most cardiovascular parameters this occurred earlier (24-48 h). Right ventricular dysfunction and increased PAP lasted longer. Acute antioxidants attenuated arterial endothelial dysfunction after diving, while reduction in heart and pulmonary artery function were unchanged. Cardiovascular changes after diving are not fully reversed up to 3 days after a dive, suggesting longer lasting negative effects.
Fulminant antenatal pulmonary oedema in a woman with hypertension and superimposed preeclampsia
Kubota-Sjogren, Yukiko; Nelson-Piercy, Catherine
2015-01-01
An asymptomatic 40-year-old para 1 black African woman with pre-existing hypertension and a booking blood pressure of 120/80 mm Hg, was admitted with superimposed preeclampsia diagnosed because of worsening hypertension and significant proteinuria at 27+5 weeks gestation. Antenatally, her blood pressure was controlled with labetalol, and blood tests including serum creatinine were within normal limits for pregnancy. Three days later, the patient developed severe hypertension despite treatment, and reported sudden onset severe shortness of breath; oxygen saturations on air dropped to 93%. Auscultation revealed widespread crepitations leading to a working diagnosis of pulmonary oedema. Despite appropriate management, respiratory function continued to deteriorate and she required intubation, ventilation and emergency caesarean section under general anaesthesia. A live male infant was delivered floppy and was intubated and resuscitated. He awaits discharge home on oxygen. The mother's pulmonary oedema resolved postpartum. Echocardiogram showed left ventricular hypertrophy but normal left ventricular function and the patient's hypertension is being controlled on medication. PMID:26607194
Babashani, M; Iliyasu, Z; Ukoli, C O
2008-01-01
The industrial process of detergent production could be deleterious to lung function. This study describes respiratory symptoms and ventilatory function impairment among detergent workers in Jos, Northern Nigeria. Two hundred detergent plant workers and controls were studied for the presence of respiratory symptoms and ventilatory function impairment using the MRC questionnaire and Spirometry. A significantly higher proportion of exposed detergent workers 178 (87.0%) reported respiratory symptoms compared to 52 (26.0%) controls [OR=23; 95% CI=12.9-41.3] (P<0.001). Commonest symptoms include rhinitis (57.5% versus 11.0%) and cough (48.5% versus 15%). Symptoms were most prevalent in the packaging section. FEV1, FVC and PEFR were significantly reduced among exposed detergent workers. Similarly, the predicted values of PEFR, FVC and FEV1, were significantly reduced among smokers (P<0. 001). Respiratory symptoms are highly prevalent among detergent workers. This was associated with impaired pulmonary function. Protective equipment and periodic lung function tests could reduce these effects.
Factors Influencing Cognitive Function in Subjects With COPD.
Dag, Ersel; Bulcun, Emel; Turkel, Yakup; Ekici, Aydanur; Ekici, Mehmet
2016-08-01
The aim of this study was to assess the association between cognitive function and age, pulmonary function, comorbidity index, and the 6-min walk distance in subjects with COPD as well as to compare the Mini Mental State Examination (MMSE) and Montreal Cognitive Assessment (MoCA) in terms of their ability to identify cognitive dysfunction in subjects with COPD. A total of 52 individuals with stable COPD were included in this study. Cognitive function was assessed using MMSE and MoCA. Age, body mass index, the Modified Cumulative Illness Rating Scale, 6-min walk distance, arterial blood gases, and pulmonary function tests were assessed and recorded. The range and SD of scores in subjects with COPD were larger with MoCA than with MMSE. MMSE and MoCA scores are associated with 6-min walk distance and comorbidity index in subjects with COPD. General cognitive function measured by MoCA was negatively correlated with the comorbidity index but was positively associated with 6-min walk distance in subjects with COPD after controlling for possible confounding factors in the multivariate model. However, general cognitive function measured by MMSE was not correlated with the comorbidity index and 6-min walk distance in subjects with COPD, after controlling for possible confounding factors in the multivariate model. MoCA may be a more reliable screening test than MMSE in detecting cognitive impairment in subjects with COPD. The addition of cognitive tests on assessment of subjects with COPD can provide further benefit. Copyright © 2016 by Daedalus Enterprises.
Hong, Eunju; Lee, Seokwon; Kim, Geun-Bae; Kim, Tae-Jong; Kim, Hyoung-Wook; Lee, Kyoungho; Son, Bu-Soon
2018-04-24
This study aims to identify environmental air pollution adversely affecting pulmonary function among a community-based general population living in Korean industrial complexes. A total of 1963 residents participated in a pulmonary function test (PFT). The sample population consisted of an exposed group ( n = 1487) living within a radius of 5 km of industrial complexes and a control group ( n = 476) living over a radius of 10 km from the industrial complexes in Gwangyang and Yeosu cities. PFT results were calculated for each resident of the study population. On-site questionnaire surveys with face-to-face interviews were also conducted to collect more detailed information on personal lifestyles, medical history, exposure to air pollution, and respiratory disease and related symptoms. A total of 486 measured samples were collected by eight automated air-monitoring stations installed in four counties of Gwangyang and four counties of Yeosu in South Korea from January 2006 to February 2007. Mean levels of SO₂ (0.012 ppm), CO (0.648 ppm), NO₂ (0.02 ppm), O₃ (0.034 ppm), and PM 10 (43.07 μg/m³), collected within a radius of 5 km, were significantly higher than those collected over a radius of 10 km from Gwangyang and Yeosu industrial complexes. Prevalence odds ratio (OR) of abnormal pulmonary function in the exposed group of residents (<5 km) was elevated at 1.24 (95% CI 0.71⁻1.96), but not statistically significant ( p > 0.05). In multiple linear regression analysis, forced expiratory volume in one second (FEV₁) and forced vital capacity (FVC) levels significantly declined as SO₂, CO, and O₃ levels increased when adjusting for age, sex, body mass index (BMI), alcohol, smoking, secondhand smoke, and respiratory disease and related symptoms ( n = 1963) ( p < 0.05). These results suggest that exposure to air pollution affects pulmonary function levels of residents living in Korean industrial complexes.
Badagliacca, Roberto; Poscia, Roberto; Pezzuto, Beatrice; Papa, Silvia; Gambardella, Cristina; Francone, Marco; Mezzapesa, Mario; Nocioni, Martina; Nona, Alfred; Rosati, Riccardo; Sciomer, Susanna; Fedele, Francesco; Dario Vizza, Carmine
2015-03-01
Right ventricular (RV) dyssynchrony has been described in pulmonary arterial hypertension (PAH), but no evidence is available on its morphologic determinants and its effect on systolic function. The aim of this study was to evaluate the morphologic determinants of RV dyssynchrony by echocardiographic and cardiac magnetic resonance imaging and its effect on systolic function. In 60 consecutive idiopathic PAH (IPAH) patients with narrow QRS, RV dyssynchrony was evaluated by 2D speckle-tracking echocardiography, calculating the standard deviation of the times to peak systolic strain for the four mid-basal RV segments (RV-SD4). Patients were grouped by the median value of RV-SD4 (19 milliseconds) and compared for RV remodeling and systolic function parameters, WHO class, pulmonary hemodynamics and 6-minute walk test (6MWT). Despite similar pulmonary vascular resistance and mean pulmonary arterial pressure, patients with RV-SD4 at >19 milliseconds had advanced WHO class and worse 6MWT, RV hemodynamics, RV remodeling and systolic function parameters compared with patients at ≤19 milliseconds. The morphologic determinants of RV dyssynchrony resulted RV end-diastolic area, LV diastolic eccentricity index and RV mass volume ratio (r = 0.69, r(2) = 0.47, p < 0.0001). Finally, we found a significant inverse correlation between RV mid-basal segments post-systolic shortening time and cardiac index (r = -0.64, r(2) = 0.41, p = 0.001), accounting for the significant correlation between RV-SD4 and cardiac index (r = 0.57, r(2) = 0.32, p = 0.003). In IPAH with narrow QRS, RV dyssynchrony is associated with RV dilation and eccentric hypertrophy pattern, suggesting a role of segmental wall stress heterogeneity as the major determinant of mechanical delay. Post-systolic shortening, as inefficient contraction, contributes to pump dysfunction. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Smargiassi, Audrey; Goldberg, Mark S; Wheeler, Amanda J; Plante, Céline; Valois, Marie-France; Mallach, Gary; Kauri, Lisa Marie; Shutt, Robin; Bartlett, Susan; Raphoz, Marie; Liu, Ling
2014-07-01
The acute cardiorespiratory effects of air quality among children living in areas with considerable heavy industry have not been well investigated. We conducted a panel study of children with asthma living in proximity to an industrial complex housing two refineries in Montreal, Quebec, in order to assess associations between their personal daily exposure to air pollutants and changes in pulmonary function and selected indicators of cardiovascular health. Seventy-two children with asthma age 7-12 years in 2009-2010 participated in this panel study for a period of 10 consecutive days. They carried a small backpack for personal monitoring of sulphur dioxide (SO2), benzene, fine particles (PM2.5), nitrogen dioxide (NO2) and polycyclic aromatic hydrocarbons (PAHs) and underwent daily spirometry and cardiovascular testing (blood pressure, pulse rate and oxygen saturation). To estimate these associations, we used mixed regression models, adjusting for within-subject serial correlation, and for the effects of a number of personal and environmental variables (e.g., medication use, ethnicity, temperature). Children with asthma involved in the study had relatively good pulmonary function test results (mean FEV1 compared to standard values: 89.8%, mean FVC: 97.6%, mean FEF25-75: 76.3%). Median diastolic, systolic blood pressures and oxygen saturation were 60/94 mmHg and 99%, respectively. Median personal concentrations of pollutants were NO2, 5.5 ppb; benzene, 2.1 µg/m(3); PM2.5, 5.7 µg/m(3); and total PAH, 130 µg/m(3). Most personal concentrations of SO2 were below the level of detection. No consistent associations were observed between cardio-pulmonary indices and personal exposure to PM2.5, NO2 and benzene, although there was a suggestion for a small decrease in respiratory function with total concentrations of PAHs (e.g., adjusted association with FVC: -9.9 ml per interquartile range 95%CI: -23.4, 3.7). This study suggests that at low daily average levels of exposure to industrial emissions, effects on pulmonary and cardiovascular functions in children with asthma may be difficult to detect over 10 consecutive days. Copyright © 2014 Elsevier Inc. All rights reserved.
Hollander, Francis M; de Roos, Nicole M; Belle van Meerkerk, Gerdien; Teding van Berkhout, Ferdinand; Heijerman, Harry G M; van de Graaf, Ed A
2017-11-01
Enteral tube feeding (ETF) is widely used in patients with cystic fibrosis (CF) and end-stage lung disease, but previous studies have been limited to investigating whether ETF improves outcomes in patients with moderately or mildly impaired pulmonary function. This study investigated body weight, body mass index (BMI; calculated as kg/m 2 ), pulmonary function, and the presence of CF-related diabetes before and after the start of ETF. This was a retrospective observational study. Data from 26 adult patients in an outpatient setting who had end-stage CF (19 women) and had been using ETF for at least 6 months between 2000 and 2014 were analyzed. Body weight, BMI, pulmonary function (forced expiratory volume in 1 second as percent of predicted) and incidence of CF-related diabetes from 6 months before to 6 months after starting ETF. Time effects were tested with one-way analysis of variance for data that were normally distributed and the Friedman test for non-parametric data. Correlations were tested with Pearson's r or Spearman's ρ, depending on the distribution of the data. Mean body weight increased by 3.5 kg (95% CI 2.2 to 4.8 kg) after patients started ETF. In women, mean BMI decreased by 0.7 in the 6 months before the start of ETF (P<0.05) and increased by 1.4 in the 6 months thereafter (P<0.05). In men, BMI changes were similar (-0.8 and +1.1), but not statistically significant. Forced expiratory volume in 1 second as percent of predicted significantly decreased in time from a median of 28% to 26% at the start of ETF to 25% after 6 months (P=0.0013), with similar trends in women and men. There was no correlation between changes in weight and lung function. CF-related diabetes was already present in 12 patients and developed in 1 more patient after the start of ETF. ETF improved body weight and BMI but not pulmonary function in 26 patients with end-stage CF. Clinical outcomes were similar in women and men, but the sample size of men was too small to determine statistical significance. Copyright © 2017 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.
González-Saiz, Laura; Fiuza-Luces, Carmen; Sanchis-Gomar, Fabian; Santos-Lozano, Alejandro; Quezada-Loaiza, Carlos A; Flox-Camacho, Angela; Munguía-Izquierdo, Diego; Ara, Ignacio; Santalla, Alfredo; Morán, María; Sanz-Ayan, Paz; Escribano-Subías, Pilar; Lucia, Alejandro
2017-03-15
Pulmonary arterial hypertension is often associated with skeletal-muscle weakness. The purpose of this randomized controlled trial was to determine the effects of an 8-week intervention combining muscle resistance, aerobic and inspiratory pressure-load exercises on upper/lower-body muscle power and other functional variables in patients with this disease. Participants were allocated to a control (standard care) or intervention (exercise) group (n=20 each, 45±12 and 46±11years, 60% women and 10% patients with chronic thromboembolic pulmonary hypertension per group). The intervention included five, three and six supervised (inhospital) sessions/week of aerobic, resistance and inspiratory muscle training, respectively. The primary endpoint was peak muscle power during bench/leg press; secondary outcomes included N-terminal pro-brain natriuretic peptide levels, 6-min walking distance, five-repetition sit-to-stand test, maximal inspiratory pressure, cardiopulmonary exercise testing variables (e.g., peak oxygen uptake), health-related quality of life, physical activity levels, and safety. Adherence to training sessions averaged 94±0.5% (aerobic), 98±0.3% (resistance) and 91±1% (inspiratory training). Analysis of variance showed a significant interaction (group×time) effect for leg/bench press (P<0.001/P=0.002), with both tests showing an improvement in the exercise group (P<0.001) but not in controls (P>0.1). We found a significant interaction effect (P<0.001) for five-repetition sit-to-stand test, maximal inspiratory pressure and peak oxygen uptake (P<0.001), indicating a training-induced improvement. No major adverse event was noted due to exercise. An 8-week exercise intervention including aerobic, resistance and specific inspiratory muscle training is safe for patients with pulmonary arterial hypertension and yields significant improvements in muscle power and other functional variables. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Burgos, Carmen Mesas; Davey, Marcus G; Riley, John S; Jia, Huimin; Flake, Alan W; Peranteau, William H
2017-12-19
Lung and pulmonary vascular maldevelopment in congenital diaphragmatic hernia (CDH) results in significant morbidity and mortality. Retinoic acid (RA) and imatinib have been shown to improve pulmonary morphology following prenatal administration in the rat nitrofen-induced CDH model. It remains unclear if these changes translate into improved function. We evaluated the effect of prenatal RA and imatinib on postnatal lung function, structure, and pulmonary artery (PA) blood flow in the rat CDH model. Olive oil or nitrofen was administered alone or in combination with RA or imatinib to pregnant rats. Pups were assessed for PA blood flow by ultrasound and pulmonary function/morphology following delivery, intubation, and short-term ventilation. Neither RA nor imatinib had a negative effect on lung and body growth. RA accelerated lung maturation indicated by increased alveoli number and thinner interalveolar septa and was associated with decreased PA resistance and improved oxygenation. With the exception of a decreased PA pulsatility index, no significant changes in morphology and pulmonary function were noted following imatinib. Prenatal treatment with RA but not imatinib was associated with improved pulmonary morphology and function, and decreased pulmonary vascular resistance. This study highlights the potential of prenatal pharmacologic therapies, such as RA, for management of CDH. Copyright © 2017 Elsevier Inc. All rights reserved.
Dubois, Luc; Malthaner, Richard A
2010-12-01
We measured lung function before and after video-assisted thoracoscopic apical bullectomy and talc poudrage in patients with spontaneous pneumothoraces. Seventy-two patients were prospectively followed up for 12 months. The indications for surgery were recurrent pneumothoraces (n = 58), bilateral pneumothoraces (n = 8), and persistent air leak (n = 6). There were 46 males and 26 females with mean age of 29 years (range 15-61 years). The results were analyzed using paired t tests. There were no recurrences. There were 4 complications (5.6%): 1 wound infection, 1 case of pneumonia, and 2 persistent air leaks each lasting 1 week. There were no conversions to open surgery. Preoperative and 6-month pulmonary function test results were available on 41 patients, and 35 patients completed 12-month pulmonary function tests. Twelve-month values (mean percent ± SD) were as follows: Forced expiratory volume in 1 second fell from 95 ± 19 to 89 ± 16 (P = .02); forced expiratory volume in 1 second/forced vital capacity ratio was unchanged, 95 ± 12 versus 94 ± 13 (P = .9); total lung capacity fell from 106 ± 19 to 98 ± 12 (P = 0.002); vital capacity fell from 100 ± 22 to 96 ± 16 (P = .05); residual volume fell from 126 ± 32 to 107 ± 29 (P = .002); and diffusion capacity for carbon monoxide corrected for alveolar volume was unchanged, 88 ± 15 versus 91 ± 17 (P = .07). Flow rates and diffusion capacities were preserved, but lung volumes were slightly reduced at 1 year. Video-assisted thoracoscopic apical bullectomy and talc poudrage is an effective treatment for spontaneous pneumothoraces with a low complication rate and recurrence rate and only minor changes in pulmonary function at 1 year. Copyright © 2010 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Guo, Jian; Zheng, Cong; Xiao, Qiang; Gong, Sugang; Zhao, Qinhua; Wang, Lan; He, Jing; Yang, Wenlan; Shi, Xue; Sun, Xingguo; Liu, Jinming
2015-10-08
This study intended to search for potential correlations between anaemia in patients with severe chronic obstructive pulmonary disease (COPD; GOLD stage III) and pulmonary function at rest, exercise capacity as well as ventilatory efficiency, using pulmonary function test (PFT) and cardiopulmonary exercise testing (CPET). The study was undertaken at Shanghai Pulmonary Hospital, a tertiary-level centre affiliated to Tongji University. It caters to a large population base within Shanghai and referrals from centres in other cities as well. 157 Chinese patients with stable severe COPD were divided into 2 groups: the anaemia group (haemoglobin (Hb) <12.0 g/dL for males, and <11 g/dL for females (n=48)) and the non-anaemia group (n=109). Arterial blood gas, PFT and CPET were tested in all patients. (1) Diffusing capacity for carbon monoxide (DLCO) corrected by Hb was significantly lower in the anaemia group ((15.3±1.9) mL/min/mm Hg) than in the non-anaemia group ((17.1±2.1) mL/min/mm Hg) (p<0.05). A significant difference did not exist in the level of forced expiratory volume in 1 s (FEV1), FEV1%pred, FEV1/forced vital capacity (FVC), inspiratory capacity (IC), residual volume (RV), total lung capacity (TLC) and RV/TLC (p>0.05). (2) Peak Load, Peak oxygen uptake (VO2), Peak VO2%pred, Peak VO2/kg, Peak O2 pulse and the ratio of VO2 increase to WR increase (ΔVO2/ΔWR) were significantly lower in the anaemia group (p<0.05); however, Peak minute ventilation (VE), Lowest VE/carbon dioxide output (VCO2) and Peak dead space/tidal volume ratio (VD/VT) were similar between the 2 groups (p>0.05). (3) A strong positive correlation was found between Hb concentration and Peak VO2 in patients with anaemia (r=0.702, p<0.01). Anaemia has a negative impact on gas exchange and exercise tolerance during exercise in patients with severe COPD. The decrease in amplitude of Hb levels is related to the quantity of oxygen uptake. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Reimberg, Mariana Mazzuca; Castro, Rejane Agnelo Silva; Selman, Jessyca Pachi Rodrigues; Meneses, Aline Santos; Politti, Fabiano; Mallozi, Márcia Carvalho; Wandalsen, Gustavo Falbo; Solé, Dirceu; De Angelis, Kátia; Dal Corso, Simone; Lanza, Fernanda Cordoba
2015-08-13
Individuals with chronic lung disease are more susceptible to present reduction in exercise tolerance and muscles strength not only due to pulmonary limitations but also due systemic repercussions of the pulmonary disease. The aim of this study is to assess the physical capacity, peripheral muscle function, physical activity in daily life, and the inflammatory markers in children and adolescents with asthma after pulmonary rehabilitation program. This is a study protocol of randomized controlled trial in asthmatic patients between 6 to 18 years old. The assessments will be conducted in three different days and will be performed at the beginning and at the end of the protocol. First visit: quality of life questionnaire, asthma control questionnaire, pre- and post-bronchodilator spirometry (400 μcg salbutamol), inflammatory assessment (blood collection), and cardiopulmonary exercise test on a cycle ergometer to determine aerobic capacity. Second visit: assessment of strength and endurance of the quadriceps femoris and biceps brachii muscles with concomitant electromyography to assess peripheral muscle strength. Third visit: incremental shuttle walk test (ISWT) and accelerometer to evaluate functional capacity and physical activity in daily life during 7 days. Then, the volunteers will be randomized to receive pulmonary rehabilitation program (intervention group) or chest physiotherapy + stretching exercises (control group). Both groups will have a supervised session, twice a week, each session will have 60 minutes duration, with minimum interval of 24 hours, for a period of 8 weeks. Intervention group: aerobic training (35 minutes) intensity between 60 to 80 % of the maximum workload of cardiopulmonary exercise testing or of ISWT; strength muscle training will be applied to the quadriceps femoris, biceps brachii and deltoid muscles (intensity: 40 to 70 % of maximal repetition, 3 x 8 repetition); finally the oral high-frequency oscillation device (Flutter®) will be used for 5 minutes. The control group: oral high-frequency oscillation device (Flutter®) for 10 minutes followed by the stretching of upper and lower limbs for 40 minutes. It is expected to observe the improvement in aerobic capacity, physical activity in daily life, muscle strength and quality of life of patients in the intervention group, and reduction in inflammatory markers. NCT02383069. Data of registration: 03/03/2015.
Vootla, Vamshidhar R; Daniel, Myrta
2015-01-01
Refeeding syndrome is defined as electrolyte and fluid abnormalities that occur in significantly malnourished patients when they are refed orally, enterally, or parenterally. The principal manifestations include hypophosphatemia, hypokalemia, vitamin deficiencies, volume overload and edema. This can affect multiple organ systems, such as the cardiovascular, pulmonary, or neurological systems, secondary to the above-mentioned abnormalities. Rarely, patients may develop gastrointestinal symptoms and show abnormal liver function test results. We report the case of a 52-year-old woman with anorexia nervosa who developed refeeding syndrome and simultaneous elevations of liver function test results, which normalized upon the resolution of the refeeding syndrome.
Evidence for chronic lung impairment in patients treated for pulmonary tuberculosis.
Vecino, Mauricio; Pasipanodya, Jotam G; Slocum, Philip; Bae, Sejong; Munguia, Guadalupe; Miller, Thaddeus; Fernandez, Michel; Drewyer, Gerry; Weis, Stephen E
2011-11-01
Patients with pulmonary tuberculosis are likely to develop pulmonary impairment after tuberculosis (PIAT). The stability of PIAT and the relationship of PIAT to the duration of delay in tuberculosis diagnosis and treatment have not been fully characterized. We performed serial pulmonary function tests (PFTs) in a cohort treated for pulmonary tuberculosis after 20 weeks of tuberculosis therapy and again on or after treatment completion to determine the stability of PIAT. PFTs were compared with the duration of delay in tuberculosis diagnosis and treatment, as well as other demographic variables. The median duration between the first and second tests was 15 (interquartile range 9-34) weeks. The mean change in FVC was -0.02l (95% confidence interval [CI] -0.09, 0.06), and the % predicted was -0.02 (95% CI -2.17, 2.12). FEV1 changes were 0l (95% CI -0.05, 0.06), and the % predicted was -0.11 (95% CI -1.82, 1.60). PIAT was not related to the duration of delay in tuberculosis diagnosis or treatment, age or smoking. PIAT was not associated with the duration of delay in tuberculosis diagnosis and treatment and did not significantly change during follow-up. These data demonstrate that, for many individuals, the completion of tuberculosis treatment is the beginning, not the end, of their tuberculosis illness. Published by Elsevier Ltd.
Harari, Sergio; Caminati, Antonella; Cassandro, Roberto; Conti, Sara; Madotto, Fabiana; Luisi, Francesca; Cesana, Giancarlo
2015-01-05
The characteristics of the six-minute walk test (6MWT) in patients with idiopathic pulmonary fibrosis (IPF) and pulmonary hypertension (PH) have not yet been described; nevertheless, this test has already been used as a "surrogate end point" in some clinical trials. Goal of this retrospective study was to assess whether the presence of PH in patients with IPF might influence 6MWT performances. We retrospectively reviewed the data of patients with IPF who were referred to our hospital. The study population was divided in two groups according to the presence or absence of PH at right heart catheterization; then, the six-minute walking distance (6MWD) and pulmonary function tests (PFTs) were compared between groups. Study population included 30 IPF patients with a mean age of 59.0 years (± 8.3), most of whom (76.7%) were males. A total of 43.3% of patients had PH. PFTs data were similar in IPF patients of the two groups; the only exception was FVC, which was significantly higher in IPF patients with PH (63.8% ± 16.0 vs. 51.6% ± 13.8 in patients without PH, p<0.05). No difference was detected between groups in 6MWD (222.3m ± 118.5 in PH group and 222.1m ± 118.5 in non-PH group, p>0.05). Our data suggested that 6MWD does not differ between IPF patients with or without PH. Thus, 6MWD should not be used as a surrogate endpoint in clinical study in patients affected by IPF and PH.
Elinoff, Jason M; Rame, J Eduardo; Forfia, Paul R; Hall, Mary K; Sun, Junfeng; Gharib, Ahmed M; Abd-Elmoniem, Khaled; Graninger, Grace; Harper, Bonnie; Danner, Robert L; Solomon, Michael A
2013-04-02
Pulmonary arterial hypertension is a rare disorder associated with poor survival. Endothelial dysfunction plays a central role in the pathogenesis and progression of pulmonary arterial hypertension. Inflammation appears to drive this dysfunctional endothelial phenotype, propagating cycles of injury and repair in genetically susceptible patients with idiopathic and disease-associated pulmonary arterial hypertension. Therapy targeting pulmonary vascular inflammation to interrupt cycles of injury and repair and thereby delay or prevent right ventricular failure and death has not been tested. Spironolactone, a mineralocorticoid and androgen receptor antagonist, has been shown to improve endothelial function and reduce inflammation. Current management of patients with pulmonary arterial hypertension and symptoms of right heart failure includes use of mineralocorticoid receptor antagonists for their diuretic and natriuretic effects. We hypothesize that initiating spironolactone therapy at an earlier stage of disease in patients with pulmonary arterial hypertension could provide additional benefits through anti-inflammatory effects and improvements in pulmonary vascular function. Seventy patients with pulmonary arterial hypertension without clinical evidence of right ventricular failure will be enrolled in a randomized, double-blinded, placebo-controlled trial to investigate the effect of early treatment with spironolactone on exercise capacity, clinical worsening and vascular inflammation in vivo. Our primary endpoint is change in placebo-corrected 6-minute walk distance at 24 weeks and the incidence of clinical worsening in the spironolactone group compared to placebo. At a two-sided alpha level of 0.05, we will have at least 84% power to detect an effect size (group mean difference divided by standard deviation) of 0.9 for the difference in the change of 6-minute walk distance from baseline between the two groups. Secondary endpoints include the effect of spironolactone on the change in placebo-corrected maximal oxygen consumption; plasma markers of vascular inflammation and peripheral blood mononuclear cell gene expression profiles; sympathetic nervous system activation, renin-angiotensin-aldosterone system activation and sex hormone metabolism; and right ventricular structure and function using echocardiography and novel high-resolution magnetic resonance imaging-based techniques. Safety and tolerability of spironolactone will be assessed with periodic monitoring for hyperkalemia and renal insufficiency as well as the incidence of drug discontinuation for untoward effects. ClinicalTrials.gov: NCT01712620.
2013-01-01
Background Pulmonary arterial hypertension is a rare disorder associated with poor survival. Endothelial dysfunction plays a central role in the pathogenesis and progression of pulmonary arterial hypertension. Inflammation appears to drive this dysfunctional endothelial phenotype, propagating cycles of injury and repair in genetically susceptible patients with idiopathic and disease-associated pulmonary arterial hypertension. Therapy targeting pulmonary vascular inflammation to interrupt cycles of injury and repair and thereby delay or prevent right ventricular failure and death has not been tested. Spironolactone, a mineralocorticoid and androgen receptor antagonist, has been shown to improve endothelial function and reduce inflammation. Current management of patients with pulmonary arterial hypertension and symptoms of right heart failure includes use of mineralocorticoid receptor antagonists for their diuretic and natriuretic effects. We hypothesize that initiating spironolactone therapy at an earlier stage of disease in patients with pulmonary arterial hypertension could provide additional benefits through anti-inflammatory effects and improvements in pulmonary vascular function. Methods/Design Seventy patients with pulmonary arterial hypertension without clinical evidence of right ventricular failure will be enrolled in a randomized, double-blinded, placebo-controlled trial to investigate the effect of early treatment with spironolactone on exercise capacity, clinical worsening and vascular inflammation in vivo. Our primary endpoint is change in placebo-corrected 6-minute walk distance at 24 weeks and the incidence of clinical worsening in the spironolactone group compared to placebo. At a two-sided alpha level of 0.05, we will have at least 84% power to detect an effect size (group mean difference divided by standard deviation) of 0.9 for the difference in the change of 6-minute walk distance from baseline between the two groups. Secondary endpoints include the effect of spironolactone on the change in placebo-corrected maximal oxygen consumption; plasma markers of vascular inflammation and peripheral blood mononuclear cell gene expression profiles; sympathetic nervous system activation, renin-angiotensin-aldosterone system activation and sex hormone metabolism; and right ventricular structure and function using echocardiography and novel high-resolution magnetic resonance imaging-based techniques. Safety and tolerability of spironolactone will be assessed with periodic monitoring for hyperkalemia and renal insufficiency as well as the incidence of drug discontinuation for untoward effects. Trial registration ClinicalTrials.gov: NCT01712620 PMID:23547564
Tanaka, Rie; Sanada, Shigeru; Okazaki, Nobuo; Kobayashi, Takeshi; Fujimura, Masaki; Yasui, Masahide; Matsui, Takeshi; Nakayama, Kazuya; Nanbu, Yuko; Matsui, Osamu
2006-10-01
Dynamic flat panel detectors (FPD) permit acquisition of distortion-free radiographs with a large field of view and high image quality. The present study was performed to evaluate pulmonary function using breathing chest radiography with a dynamic FPD. We report primary results of a clinical study and computer algorithm for quantifying and visualizing relative local pulmonary airflow. Dynamic chest radiographs of 18 subjects (1 emphysema, 2 asthma, 4 interstitial pneumonia, 1 pulmonary nodule, and 10 normal controls) were obtained during respiration using an FPD system. We measured respiratory changes in distance from the lung apex to the diaphragm (DLD) and pixel values in each lung area. Subsequently, the interframe differences (D-frame) and difference values between maximum inspiratory and expiratory phases (D-max) were calculated. D-max in each lung represents relative vital capacity (VC) and regional D-frames represent pulmonary airflow in each local area. D-frames were superimposed on dynamic chest radiographs in the form of color display (fusion images). The results obtained using our methods were compared with findings on computed tomography (CT) images and pulmonary functional test (PFT), which were examined before inclusion in the study. In normal subjects, the D-frames were distributed symmetrically in both lungs throughout all respiratory phases. However, subjects with pulmonary diseases showed D-frame distribution patterns that differed from the normal pattern. In subjects with air trapping, there were some areas with D-frames near zero indicated as colorless areas on fusion images. These areas also corresponded to the areas showing air trapping on computed tomography images. In asthma, obstructive abnormality was indicated by areas continuously showing D-frame near zero in the upper lung. Patients with interstitial pneumonia commonly showed fusion images with an uneven color distribution accompanied by increased D-frames in the area identified as normal on computed tomography images. Furthermore, measurement of DLD was very effective for evaluating diaphragmatic kinetics. This is a rapid and simple method for evaluation of respiratory kinetics for pulmonary diseases, which can reveal abnormalities in diaphragmatic kinetics and regional lung ventilation. Furthermore, quantification and visualization of respiratory kinetics is useful as an aid in interpreting dynamic chest radiographs.
Quantitative computed tomography and aerosol morphometry in COPD and alpha1-antitrypsin deficiency.
Shaker, S B; Maltbaek, N; Brand, P; Haeussermann, S; Dirksen, A
2005-01-01
Relative area of emphysema below -910 Hounsfield units (RA-910) and 15th percentile density (PD15) are quantitative computed tomography (CT) parameters used in the diagnosis of emphysema. New concepts for noninvasive diagnosis of emphysema are aerosol-derived airway morphometry, which measures effective airspace dimensions (EAD) and aerosol bolus dispersion (ABD). Quantitative CT, ABD and EAD were compared in 20 smokers with chronic obstructive pulmonary disease (COPD) and 22 patients with alpha1-antitrypsin deficiency (AAD) with a similar degree of airway obstruction and reduced diffusion capacity. In both groups, there was a significant correlation between RA-910 and PD15 and pulmonary function tests (PFTs). A significant correlation was also found between EAD, RA-910 and PD15 in the study population as a whole. Upon separation into two groups, the significance disappeared for the smokers with COPD and strengthened for those with AAD, where EAD correlated significantly with RA-910 and PD15. ABD was similar in the two groups and did not correlate with PFT and quantitative CT in either group. In conclusion, based on quantitative computed tomography and aerosol-derived airway morphometry, emphysema was significantly more severe in patients with alpha1-antitrypsin deficiency compared with patients with usual emphysema, despite similar measures of pulmonary function tests.
Computed tomography in pulmonary sarcoidosis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lynch, D.A.; Webb, W.R.; Gamsu, G.
1989-05-01
We studied the high resolution CT (HRCT) scans of 15 patients with biopsy-proven sarcoidosis and correlated the findings with pulmonary function tests (12 patients), 67Ga scans (10 patients), bronchoalveolar lavage (five patients), recent transbronchial biopsy (six patients), and recent open lung biopsy (three patients). The HRCT features included small nodules, thickened interlobular septa, patchy focal increase in lung density, honeycombing, and central conglomeration of vessels and bronchi. Active alveolitis was present by gallium scanning criteria in 5 of 10 cases. By bronchoalveolar lavage criteria, activity was present in three of five cases. Patchy increase in density may correlate with activemore » alveolitis as seen on /sup 67/Ga scanning. High resolution CT was better than chest X-radiography for demonstration of patchy increase in density and for distinguishing nodules from septal thickening. Both nodules and patchy density were partly reversible following therapy. Nodular densities seen on CT correlated with the presence of granulomata on histology. Resting pulmonary function tests correlated poorly with presence and extent of lung disease on HRCT. The presence on HRCT of focal fine nodules, patchy focal increase in lung density, and central crowding of bronchi and vessels should suggest the diagnosis of sarcoidosis. In some patients, HRCT can identify unsuspected parenchymal lung disease and document the reversible components of sarcoid lung disease.« less
Plachi, Franciele; Balzan, Fernanda M; Sanseverino, Renata A; Palombini, Dora V; Marques, Renata D; Clausell, Nadine O; Knorst, Marli M; Neder, J Alberto; Berton, Danilo C
2018-02-21
Aim To investigate if cardiac/pulmonary functional tests and variables obtained from clinical practice (body mass index, dyspnea, functional class, clinical judgment of disability to perform an exercise test and previous hospitalization rate) are related to mortality in patients with overlap chronic obstructive pulmonary disease (COPD) and chronic heart failure (CHF). Although the coexistence of COPD and CHF has been growingly reported, description of survival predictors considering the presence of both conditions is still scarce. Using a cohort design, outpatients with the previous diagnosis of COPD and/or CHF that performed both spirometry and echocardiography in the same year were followed-up during a mean of 20.9±8.5 months. Findings Of the 550 patients initially evaluated, 301 had both spirometry and echocardiography: 160 (53%) with COPD on isolation; 100 (33%) with CHF on isolation; and 41 (14%) with overlap. All groups presented similar mortality: COPD 17/160 (11%); CHF 12/100 (12%); and overlap 7/41 (17%) (P=0.73). In the overlap group (n=41), inability to exercise and hospitalization rate were the unique parameters associated with higher mortality (seven events) in univariate analyses. In conclusion, inability to exercise and hospitalization rate emerged as the unique parameters associated with mortality in our sample.
Otsuka, K.; Norboo, T.; Otsuka, Y.; Higuchi, H.; Hayajiri, M.; Narushima, C.; Sato, Y.; Tsugoshi, T.; Murakami, S.; Wada, T.; Ishine, M.; Okumiya, K.; Matsubayashi, K.; Yano, S.; Chogyal, T.; Angchuk, D.; Ichihara, K.; Cornélissen, G.; Halberg, F.
2008-01-01
Effects of high altitude on arterial stiffness and neuro-cardio-pulmonary function were studied. Blood pressure (BP) and heart rate (HR) were measured in a sitting position on resting Ladakhis, living at an altitude of 3250–4647 m (Phey village, 3250 m: 17 men and 55 women; Chumathang village, 4193 m: 29 men and 47 women; Sumdo village, 4540 m: 38 men and 57 women; and Korzok village, 4647 m: 84 men and 70 women). The neuro-cardio-pulmonary function, including the Kohs block design test, the Up and Go, the Functional Reach and the Button tests, was examined in 40 elderly subjects (19 men and 21 women, mean age: 74.7 ± 3.3 years) in Leh, Ladakh (altitude: 3524 m), for comparison with 324 elderly citizens (97 men and 227 women, mean age: 80.7 ± 4.7 years) of Tosa, Japan (altitude: 250 m). Cardio-Ankle Vascular Index (CAVI) was measured as the heart-ankle pulse wave velocity (PWV) in these subjects using a VaSera CAVI instrument (Fukuda Denshi, Tokyo). SpO2 decreased while Hb and diastolic BP increased with increasing altitude. At higher altitude, residents were younger and leaner. Women in Leh vs. Tosa had a poorer cognitive function, estimated by the Kohs block design test (3.7 ± 3.6 vs. 16.4 ± 9.6 points, P < 0.0001) and poorer ADL functions (Functional Reach: 13.7 ± 7.0 cm vs. 25.3 ± 8.7 cm, P < 0.0001; Button test: 22.5 ± 4.8 vs. 14.8 ± 5.7 s, P < 0.0001). Time estimation was shorter at high altitude (60-s estimation with counting: 41.1% shorter in men and 23.0% shorter in women). A higher voltage of the QRS complex was observed in the ECG of Leh residents, but two times measurement of CAVI showed no statistically significant differences between Leh and Tosa (two times of CAVI measures; 9.49 vs. 10.01 rn/s and 9.41 vs. 10.05 m/s, respectively), suggesting that most residents succeed to adapt sufficiently to the high-altitude environment. However, correlation of CAVI with age shows several cases who show an extreme increase in CAVI. Thus, for the prevention of stroke and other adverse cardiovascular outcomes, including dementia, CAVI may be very useful, especially at high altitude. In conclusion, elderly people living at high altitude have a higher risk of cardiovascular disease than low-latitude peers. To determine how these indices are associated with maintained cognitive function deserves further study by the longitudinal follow-up of these communities in terms of longevity and aging in relation to their neuro-cardio-pulmonary function. PMID:16275510
Lechtzin, N; West, N; Allgood, S; Wilhelm, E; Khan, U; Mayer-Hamblett, N; Aitken, M L; Ramsey, B W; Boyle, M P; Mogayzel, P J; Goss, C H
2013-11-01
Acute pulmonary exacerbations are central events in the lives of individuals with cystic fibrosis (CF). Pulmonary exacerbations lead to impaired lung function, worse quality of life, and shorter survival. We hypothesized that aggressive early treatment of acute pulmonary exacerbation may improve clinical outcomes. Describe the rationale of an ongoing trial designed to determine the efficacy of home monitoring of both lung function measurements and symptoms for early detection and subsequent early treatment of acute CF pulmonary exacerbations. A randomized, non-blinded, multi-center trial in 320 individuals with CF aged 14 years and older. The study compares usual care to a twice a week assessment of home spirometry and CF respiratory symptoms using an electronic device with data transmission to the research personnel to identify and trigger early treatment of CF pulmonary exacerbation. Participants will be enrolled in the study for 12 months. The primary endpoint is change in FEV1 (L) from baseline to 12 months determined by a linear mixed effects model incorporating all quarterly FEV1 measurements. Secondary endpoints include time to first acute protocol-defined pulmonary exacerbation, number of acute pulmonary exacerbations, number of hospitalization days for acute pulmonary exacerbation, time from the end of acute pulmonary exacerbation to onset of subsequent pulmonary exacerbation, change in health related quality of life, change in treatment burden, change in CF respiratory symptoms, and adherence to the study protocol. This study is a first step in establishing alternative approaches to the care of CF pulmonary exacerbations. We hypothesize that early treatment of pulmonary exacerbations has the potential to slow lung function decline, reduce respiratory symptoms and improve the quality of life for individuals with CF. © 2013.
Emad, A; Rezaian, G R
1997-09-01
To find out the late pulmonary sequelae of sulfur mustard gas inhalation in 197 veterans, 10 years after their exposure. Cross-sectional clinical study. University hospital. One hundred ninety-seven veterans with a single, heavy exposure to sulfur mustard gas in 1986 and 86 nonexposed veterans as their control group. Pulmonary function tests, carbon monoxide diffusion capacity, bronchoscopy, and high-resolution CT of the chest were performed in all patients. Transbronchial lung biopsy was done in 24 suspected cases of pulmonary fibrosis. Asthma was diagnosed in 21 (10.65%), chronic bronchitis in 116 (58.88%), bronchiectasis in 17 (8.62%), airway narrowing due to searing or granulation tissue in 19 (9.64%), and pulmonary fibrosis in 24 (12.18%) cases. None of these were found among the control group except for a single case of chronic bronchitis. Although the respiratory symptoms of an acute sulfur mustard gas inhalation are usually transient and nonspecific, it can lead to the development of a series of chronic destructive pulmonary sequelae in such cases.
NASA Astrophysics Data System (ADS)
Hunter, Kendall; Zhang, Yanhang; Lanning, Craig
2005-11-01
Insight into the progression of pulmonary hypertension may be obtained from thorough study of vascular flow during reactivity testing, an invasive diagnostic procedure which can dramatically alter vascular hemodynamics. Diagnostic imaging methods, however, are limited in their ability to provide extensive data. Here we present detailed flow and wall deformation results from simulations of pulmonary arteries undergoing this procedure. Patient-specific 3-D geometric reconstructions of the first four branches of the pulmonary vasculature were obtained clinically and meshed for use with computational software. Transient simulations in normal and reactive states were obtained from four such models were completed with patient-specific velocity inlet conditions and flow impedance exit conditions. A microstructurally based orthotropic hyperelastic model that simulates pulmonary artery mechanics under normotensive and hypoxic hypertensive conditions treated wall constitutive changes due to pressure reactivity and arterial remodeling. Pressure gradients, velocity fields, arterial deformation, and complete topography of shear stress were obtained. These models provide richer detail of hemodynamics than can be obtained from current imaging techniques, and should allow maximum characterization of vascular function in the clinical situation.
Cannon, John E.; Su, Li; Kiely, David G.; Page, Kathleen; Toshner, Mark; Swietlik, Emilia; Treacy, Carmen; Ponnaberanam, Anie; Condliffe, Robin; Sheares, Karen; Taboada, Dolores; Dunning, John; Tsui, Steven; Ng, Choo; Gopalan, Deepa; Screaton, Nicholas; Elliot, Charlie; Gibbs, Simon; Howard, Luke; Corris, Paul; Lordan, James; Johnson, Martin; Peacock, Andrew; MacKenzie-Ross, Robert; Schreiber, Benji; Coghlan, Gerry; Dimopoulos, Kostas; Wort, Stephen J.; Gaine, Sean; Moledina, Shahin; Jenkins, David P.; Pepke-Zaba, Joanna
2018-01-01
Background Chronic thromboembolic pulmonary hypertension results from incomplete resolution of pulmonary emboli. Pulmonary endarterectomy (PEA) is potentially curative, but residual pulmonary hypertension following surgery is common and its impact on long-term outcome is poorly understood. We wanted to identify factors correlated with poor long-term outcome after surgery and specifically define clinically relevant residual pulmonary hypertension post-PEA. Methods and Results Eight hundred eighty consecutive patients (mean age, 57 years) underwent PEA for chronic thromboembolic pulmonary hypertension. Patients routinely underwent detailed reassessment with right heart catheterization and noninvasive testing at 3 to 6 months and annually thereafter with discharge if they were clinically stable at 3 to 5 years and did not require pulmonary vasodilator therapy. Cox regressions were used for survival (time-to-event) analyses. Overall survival was 86%, 84%, 79%, and 72% at 1, 3, 5, and 10 years for the whole cohort and 91% and 90% at 1 and 3 years for the recent half of the cohort. The majority of patient deaths after the perioperative period were not attributable to right ventricular failure (chronic thromboembolic pulmonary hypertension). At reassessment, a mean pulmonary artery pressure of ≥30 mm Hg correlated with the initiation of pulmonary vasodilator therapy post-PEA. A mean pulmonary artery pressure of ≥38 mm Hg and pulmonary vascular resistance ≥425 dynes·s–1·cm–5 at reassessment correlated with worse long-term survival. Conclusions Our data confirm excellent long-term survival and maintenance of good functional status post-PEA. Hemodynamic assessment 3 to 6 months and 12 months post-PEA allows stratification of patients at higher risk of dying of chronic thromboembolic pulmonary hypertension and identifies a level of residual pulmonary hypertension that may guide the long-term management of patients postsurgery. PMID:27052413
Clinical Significance of Symptoms in Smokers with Preserved Pulmonary Function.
Woodruff, Prescott G; Barr, R Graham; Bleecker, Eugene; Christenson, Stephanie A; Couper, David; Curtis, Jeffrey L; Gouskova, Natalia A; Hansel, Nadia N; Hoffman, Eric A; Kanner, Richard E; Kleerup, Eric; Lazarus, Stephen C; Martinez, Fernando J; Paine, Robert; Rennard, Stephen; Tashkin, Donald P; Han, MeiLan K
2016-05-12
Currently, the diagnosis of chronic obstructive pulmonary disease (COPD) requires a ratio of forced expiratory volume in 1 second (FEV1) to forced vital capacity (FVC) of less than 0.70 as assessed by spirometry after bronchodilator use. However, many smokers who do not meet this definition have respiratory symptoms. We conducted an observational study involving 2736 current or former smokers and controls who had never smoked and measured their respiratory symptoms using the COPD Assessment Test (CAT; scores range from 0 to 40, with higher scores indicating greater severity of symptoms). We examined whether current or former smokers who had preserved pulmonary function as assessed by spirometry (FEV1:FVC ≥0.70 and an FVC above the lower limit of the normal range after bronchodilator use) and had symptoms (CAT score, ≥10) had a higher risk of respiratory exacerbations than current or former smokers with preserved pulmonary function who were asymptomatic (CAT score, <10) and whether those with symptoms had different findings from the asymptomatic group with respect to the 6-minute walk distance, lung function, or high-resolution computed tomographic (HRCT) scan of the chest. Respiratory symptoms were present in 50% of current or former smokers with preserved pulmonary function. The mean (±SD) rate of respiratory exacerbations among symptomatic current or former smokers was significantly higher than the rates among asymptomatic current or former smokers and among controls who never smoked (0.27±0.67 vs. 0.08±0.31 and 0.03±0.21 events, respectively, per year; P<0.001 for both comparisons). Symptomatic current or former smokers, regardless of history of asthma, also had greater limitation of activity, slightly lower FEV1, FVC, and inspiratory capacity, and greater airway-wall thickening without emphysema according to HRCT than did asymptomatic current or former smokers. Among symptomatic current or former smokers, 42% used bronchodilators and 23% used inhaled glucocorticoids. Although they do not meet the current criteria for COPD, symptomatic current or former smokers with preserved pulmonary function have exacerbations, activity limitation, and evidence of airway disease. They currently use a range of respiratory medications without any evidence base. (Funded by the National Heart, Lung, and Blood Institute and the Foundation for the National Institutes of Health; SPIROMICS ClinicalTrials.gov number, NCT01969344.).
Ophir, Noa; Shai, Amir Bar; Alkalay, Yifat; Israeli, Shani; Korenstein, Rafi; Kramer, Mordechai R; Fireman, Elizabeth
2016-01-01
The manufacture of kitchen and bath countertops in Israel is based mainly on artificial stone that contains 93% silica as natural quartz, and ∼3500 workers are involved in cutting and processing it. Artificial stone produces high concentrations of silica dust. Exposure to crystalline silica may cause silicosis, an irreversible lung disease. Our aim was to screen exposed workers by quantitative biometric monitoring of functional and inflammatory parameters. 68 exposed artificial stone workers were compared to 48 nonexposed individuals (controls). Exposed workers filled in questionnaires, and all participants underwent pulmonary function tests and induced sputum analyses. Silica was quantitated by a Niton XL3 X-ray fluorescence spectrometer. Pulmonary function test results of exposed workers were significantly lower and induced sputa showed significantly higher neutrophilic inflammation compared to controls; both processes were slowed down by the use of protective measures in the workplace. Particle size distribution in induced sputum samples of exposed workers was similar to that of artificial stone dust, which contained aluminium, zirconium and titanium in addition to silica. In conclusion, the quantitation of biometric parameters is useful for monitoring workers exposed to artificial stone in order to avoid deterioration over time.
Cullen, Kate; Talbot, Daniel; Gillmor, Julie; McGrath, Colin; OʼDonnell, Rory; Baily-Scanlan, Maria; Broderick, Julie
2017-07-01
Anxiety and depression are prevalent comorbidities in people with chronic respiratory diseases (CRDs). This study sought to quantify the influence of varying degrees of anxiety and depression on functional performance and disease impact in a population with CRDs following pulmonary rehabilitation (PR) intervention. The Hospital Anxiety and Depression Scale (HADS), the 6-Minute Walk Test (6MWT), and the Chronic Obstructive Pulmonary Disease Assessment Test (CAT) were assessed pre- and post-PR. Participants were categorized into 3 groups (None, Probable, and Present) based on their level of anxiety and depression. Functional performance and disease impact outcomes were compared pre- and post-PR. Patients consisted of a total of 134 program completers (72 males, 62 females; mean age = 67.8 years). Significant improvements in functional performance with regard to 6MWT scores were observed across all groups postintervention (P < .05). The Present group, in both the anxiety and depression domains, failed to reach a minimally clinically important difference postintervention. The Probable and Present groups achieved a significant improvement in CAT scores postintervention (P < .05). This study showed that symptoms of anxiety and depression in people with CRDs were significantly related to lower exercise tolerance levels and higher levels of disease impact. People with increased levels of anxiety and depression have the potential to significantly improve disease impact outcomes post-PR. The results demonstrated that the detection and treatment of anxiety and depression symptoms in people with CRDs are likely to be clinically important.
Becker, Tara; Laxova, Anita; Grieve, Adam; Racine Gilles, Caroline N.; Rock, Michael J.; Gershan, William M.; Green, Christopher G.; Farrell, Philip M.
2011-01-01
Background: The objective of this study was to examine relationships between pulmonary health and health-related quality of life (HRQOL) in patients with cystic fibrosis (CF) evaluated longitudinally in the Wisconsin Newborn Screening Project. Methods: Patients aged 8 to 18 years (mean ± SD, 13.5 ± 2.8) in early diagnosis (n = 45) and control (n = 50) groups completed Cystic Fibrosis Questionnaires (CFQs) to measure HRQOL at three data points over a 2-year period. Pulmonary health was evaluated concurrently by the Wisconsin chest x-ray scoring system (WCXR) and pulmonary function tests (PFTs). Results: WCXR showed significant group differences (P ≤ .023), with the early diagnosis group showing more-severe lung disease. When adjusted for group differences in mucoid Pseudomonas aeruginosa status and pancreatic status, however, WCXR differences and PFT data were not significant. Most patients (74%) had FEV1 values ≥ 80% predicted (within normal range). For patients aged < 14 years, as WCXR scores worsened CFQ respiratory and physical domain scores decreased (both P ≤ .007). FEV1/FVC showed a positive relationship with the respiratory and physical domains (both P ≤ .006). WCXR scores for patients aged ≥ 14 years were associated with CFQ weight, respiratory, and health domains (all P ≤ .011). FEV1 was associated with CFQ weight, respiratory, health, and physical domains (all P ≤ .003). Changes in pulmonary health were not associated with changes in CFQ over time. Significant group differences on the CFQ-Child social functioning domain favored the control group. Conclusions: To our knowledge, this study is the first to compare pulmonary outcomes with HRQOL indicators assessed by serial, standardized, patient-reported outcome measures for patients with CF identified either through newborn screening or diagnosed by use of traditional methods. This study found no benefits of newborn screening for pulmonary health or HRQOL after controlling for risk factors. Using WCXR and PFT data collectively helped to identify associations between pulmonary health and HRQOL. PMID:21106659
Oral challenge test with sodium metabisulfite in steroid-dependent asthmatic patients.
Prieto, L; Juyol, M; Paricio, A; Martínez, M A; Palop, J; Castro, J
1988-01-01
Oral challenge tests were carried out with sodium metabisulfite solution doses of 0.5, 1, 10, 25, 50 mg and encapsulated doses of 100 and 200 mg, as well as with lactose-placebo, on 44 non-atopic patients with steroid-dependent bronchial asthma, without clinical evidence of intolerance to these agents. Only those patients with an acceptable and not very labile pulmonary function were tested. A single-blind challenge protocol was performed in 22 patients (sodium metabisulfite solutions at pH 2.2 to 2.6) and the positive responses were confirmed by double-blind challenge. The other 22 were tested directly in a double-blind manner (pH4). Initially, 6/44 presented a positive reaction. However, a careful analysis and the confirmation by double-blind challenge of the positive responses obtained with the single-blind test, allowed us to identify 4 false positive responses. Thus, the true prevalence of sulfite sensitivity in our population is 4.5%. A patient with intolerance to sulfite agents also suffered aspirin-induced asthma. The labile tendency of the pulmonary function of the asthmatic patients may have contributed to some false positive reactions and probably explain the very high prevalence found in some studies. It does not appear that the variations of pH decisively influence the result of the challenge test.
Coates, Allan L; Graham, Brian L; McFadden, Robin G; McParland, Colm; Moosa, Dilshad; Provencher, Steeve; Road, Jeremy
2013-01-01
Canadian Thoracic Society (CTS) clinical guidelines for asthma and chronic obstructive pulmonary disease (COPD) specify that spirometry should be used to diagnose these diseases. Given the burden of asthma and COPD, most people with these diseases will be diagnosed in the primary care setting. The present CTS position statement was developed to provide guidance on key factors affecting the quality of spirometry testing in the primary care setting. The present statement may also be used to inform and guide the accreditation process for spirometry in each province. Although many of the principles discussed are equally applicable to pulmonary function laboratories and interpretation of tests by respirologists, they are held to a higher standard and are outside the scope of the present statement. PMID:23457669
The frequency of pulmonary hypertension in patients with juvenile scleroderma.
Adrovic, Amra; Oztunc, Funda; Barut, Kenan; Koka, Aida; Gojak, Refet; Sahin, Sezgin; Demir, Tuncalp; Kasapcopur, Ozgur
2015-08-22
Juvenile scleroderma (JS) represents a rarely seen group of connective tissue diseases with multiple organ involvement. Cardiac involvement in JSS is well known and, although rare in children, it may be an important cause of mortality and morbidity. Therefore, an early determination of cardio-vascular and pulmonary involvement is of the most relevance to reduce the mortality in patients with juvenile scleroderma. The aim of the study was to explore the non-invasive methods (Doppler echocardiography, pulmonary function tests), Forced vital capacity (FVC) and Carbon monoxide diffusion capacity (DLCO) in the assessment of the cardiopulmonary involvement in patients with JS. The assessment of pulmonary arterial pressure (PAP) and risk factors for pulmonary arterial hypertension (PAH) were made by the measurement of maximum tricuspid insufficiency (TI), end-diastolic pulmonary insufficiency (PI), ratio of acceleration time (AT) to ejection time (ET) (AT/ET), right atrial pressure (RAP) and contraction of vena cava inferior during inspiration. Thirty-five patients with confirmed JS were included in the study. The mean age of onset of the disease was 9.57 years (median 10 years, range 2-18 years). The mean disease duration and follow-up time was 2 years (median 1 year, range 0.5-8 years) and 3.57 years (median 2 years, range 0.5-14.5 years), respectively.The values of all the analyzed parameters including TI, PI, AT/ET, PAP, FVC and DLCO were found to be within normal ranges in all the patients tested, confirming an uncommonness of cardiopulmonary involvement in patients with juvenile scleroderma.
Stoliński, Jarosław; Musiał, Robert; Plicner, Dariusz; Andres, Janusz
The aim of the study was to comparatively analyze respiratory system function after minimally invasive, through right minithoracotomy aortic valve replacement (RT-AVR) to conventional AVR. Analysis of 201 patients scheduled for RT-AVR and 316 for AVR between January 2010 and November 2013. Complications of the respiratory system and pulmonary functional status are presented. Complications of the respiratory system occurred in 16.8% of AVR and 11.0% of RT-AVR patients (P = 0.067). The rate of pleural effusions, thoracenteses, pneumonias, or phrenic nerve dysfunctions was not significantly different between groups. Perioperative mortality was 1.9% in AVR and 1.0% in RT-AVR (P = 0.417). Mechanical ventilation time after surgery was 9.7 ± 5.9 hours for AVR and 7.2 ± 3.2 hours for RT-AVR patients (P < 0.001). Stroke (odds ratio [OR] = 13.4, P = 0.008), increased postoperative blood loss (OR = 9.6, P < 0.001), and chronic obstructive pulmonary disease (OR = 7.7, P < 0.001) were risk factors of prolonged mechanical lung ventilation. A week after surgery, the results of most pulmonary function tests were lower in the AVR than in the RT-AVR group (P < 0.001 was seen for forced expiratory volume in the first second, vital capacity, total lung capacity, maximum inspiratory pressure and maximum expiratory pressure, P = 0.377 was seen for residual volume). Right anterior aortic valve replacement minithoracotomy surgery with single-lung ventilation did not result in increased rate of respiratory system complications. Spirometry examinations revealed that pulmonary functional status was more impaired after AVR in comparison with RT-AVR surgery.
Genetic Association Analysis of Functional Impairment in Chronic Obstructive Pulmonary Disease
Hersh, Craig P.; DeMeo, Dawn L.; Lazarus, Ross; Celedón, Juan C.; Raby, Benjamin A.; Benditt, Joshua O.; Criner, Gerard; Make, Barry; Martinez, Fernando J.; Scanlon, Paul D.; Sciurba, Frank C.; Utz, James P.; Reilly, John J.; Silverman, Edwin K.
2006-01-01
Rationale: Patients with severe chronic obstructive pulmonary disease (COPD) may have varying levels of disability despite similar levels of lung function. This variation may reflect different COPD subtypes, which may have different genetic predispositions. Objectives: To identify genetic associations for COPD-related phenotypes, including measures of exercise capacity, pulmonary function, and respiratory symptoms. Methods: In 304 subjects from the National Emphysema Treatment Trial, we genotyped 80 markers in 22 positional and/or biologically plausible candidate genes. Regression models were used to test for association, using a test–replication approach to guard against false-positive results. For significant associations, effect estimates were recalculated using the entire cohort. Positive associations with dyspnea were confirmed in families from the Boston Early-Onset COPD Study. Results: The test–replication approach identified four genes—microsomal epoxide hydrolase (EPHX1), latent transforming growth factor-β binding protein-4 (LTBP4), surfactant protein B (SFTPB), and transforming growth factor-β1 (TGFB1)—that were associated with COPD-related phenotypes. In all subjects, single-nucleotide polymorphisms (SNPs) in EPHX1 (p ⩽ 0.03) and in LTBP4 (p ⩽ 0.03) were associated with maximal output on cardiopulmonary exercise testing. Markers in LTBP4 (p ⩽ 0.05) and SFTPB (p = 0.005) were associated with 6-min walk test distance. SNPs in EPHX1 were associated with carbon monoxide diffusing capacity (p ⩽ 0.04). Three SNPs in TGFB1 were associated with dyspnea (p ⩽ 0.002), one of which replicated in the family study (p = 0.02). Conclusions: Polymorphisms in several genes seem to be associated with COPD-related traits other than FEV1. These associations may identify genes in pathways important for COPD pathogenesis. PMID:16456143
Cheng, Guang-Shing; Campbell, Angela P.; Xie, Hu; Stednick, Zach; Callais, Cheryl; Leisenring, Wendy M.; Englund, Janet A.; Chien, Jason W.; Boeckh, Michael
2016-01-01
BACKGROUND Early detection of subclinical lung function decline may help identify allogeneic hematopoietic cell transplantation (HCT) recipients who are at increased risk for late non-infectious pulmonary complications including bronchiolitis obliterans syndrome (BOS). We evaluated the use of handheld spirometry in this population. METHODS Allogeneic HCT recipients enrolled in a single center observational trial performed weekly spirometry with a handheld spirometer for one year after transplantation. Participants performed pulmonary function tests in an outpatient laboratory setting at 3 time points: pre-transplant, day 80 and 1 year post-transplant. Correlation between the two methods was assessed by Pearson and Spearman correlations; agreement was assessed using Bland-Altman plots. RESULTS A total of 437 subjects had evaluable pulmonary function tests. Correlation for FEV1 was r=0.954 (p<.0001) at day 80 and r=0.931 (p<.0001) at 1 year when the handheld and laboratory tests were performed within one day of each other. Correlation for handheld FEV6 with laboratory FVC was r=0.914 (p<.0001) at day 80 and r=0.826 (p<.0001) at 1 year. The bias, or the mean difference (handheld minus laboratory) for FEV1 at day 80 and 1 year was −0.13L (−0.63, 0.37) and −0.10L (−0.77, 0.56), respectively. FEV6 showed greater bias at day 80 [−0.51L (−1.44, 0.42)] and 1 year [−0.40L (−1.81, 1.01)]. CONCLUSIONS Handheld spirometry correlated well with laboratory spirometry after allogeneic HCT and may be useful for self-monitoring of patients for early identification of airflow obstruction. PMID:26748162
Castrejon-Vázquez, Isabel; Vargas, Maria Eugenia; Sabido, Raúl Cicero; Tapía, Jorge Galicia
2012-01-01
Background Spirometry is a very useful clinical test to evaluate pulmonary function in asthma. However pulmonary function could be affected by the sex, time of clinical evolution, lung age (LA) and chronological age (CA). The aim of this study was to evaluate LA/CA as index of clinical improvement or severity in asthma patients. Methods The tenets of the Declaration of Helsinki were followed, and all patients gave their informed consent to participate in this study. Asthma severity was evaluated according with GINA classification. Spirometry was performed at the beginning of this study, at 46 days, 96 days, 192 days and after 8 months. Statistical analysis was performed using t test, 2-way ANOVA test, correlation and multiple regression models as well as ROC curves were also performed, a P < 0.05 was considered as significant. Results 70 asthma patients were included (22 male and 48 female), mean CA was 35-years old; mean LA was 48-years with a LA/CA index = 1.4, time of clinical evolution was 13 years. A LA/CA index = 1 (range 0.5 to 0.9) was observed in asymptomatic patients. LA/CA index over 1 were related with airway inflammation, and a LA/CA index more than 2 correlated with GINA step 3. Interestingly when we analyzed CA and LA, we observed that in female group more than 10 years of difference between CA and LA, (GINA Step2 and 3); while in male we observed (GINA Step1, Step2 and Step3). LA/CA index ≤ 1 was considered as normal. Conclusions LA/CA index is a good as clinical indicator of clinical improvement or severity in asthma patients in with excellent correlation of pulmonary function and age.
Goggs, R; Chan, D L; Benigni, L; Hirst, C; Kellett-Gregory, L; Fuentes, V L
2014-04-01
To evaluate the feasibility of CT pulmonary angiography for identification of naturally occurring pulmonary thromboembolism in dogs using predefined diagnostic criteria and to assess the ability of echocardiography, cardiac troponins, D-dimers and kaolin-activated thromboelastography to predict the presence of pulmonary thromboembolism in dogs. Twelve dogs with immune-mediated haemolytic anaemia and evidence of respiratory distress were prospectively evaluated. Dogs were sedated immediately before CT pulmonary angiography using intravenous butorphanol. Spiral CT pulmonary angiography was performed with a 16 detector-row CT scanner using a pressure injector to infuse contrast media through peripheral intravenous catheters. Pulmonary thromboembolism was diagnosed using predefined criteria. Contemporaneous tests included echocardiography, arterial blood gas analysis, kaolin-activated thromboelastography, D-dimers and cardiac troponins. Based on predefined criteria, four dogs were classified as pulmonary thromboembolism positive, three dogs were suspected to have pulmonary thromboembolism and the remaining five dogs had negative scans. The four dogs identified with pulmonary thromboembolism all had discrete filling defects in main or lobar pulmonary arteries. None of the contemporaneous tests was discriminant for pulmonary thromboembolism diagnosis, although the small sample size was limiting. CT pulmonary angiography can be successfully performed in dogs under sedation, even in at-risk patients with respiratory distress and can both confirm and rule out pulmonary thromboembolism in dogs. © 2014 British Small Animal Veterinary Association.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koenig, J.Q.; Covert, D.S.; Smith, M.S.
Separate exposures to 0.12 ppm ozone (O3) or 0.18 ppm nitrogen dioxide (NO2) have not demonstrated consistent changes in pulmonary function in adolescent subjects. However, in polluted urban air, O3 and NO2 occur in combination. Therefore, this project was designed to investigate the pulmonary effects of combined O3 and NO2 exposures during intermittent exercise in adolescent subjects. Twelve healthy and twelve well-characterized asthmatic adolescent subjects were exposed randomly to clean air or 0.12 ppm O3 and 0.30 ppm NO2 alone or in combination during 60 minutes of intermittent moderate exercise (32.5 1/min). The inhalation exposures were carried out while themore » subjects breathed on a rubber mouthpiece with nose clips in place. The following pulmonary functional values were measured before and after exposure: peak flow, total respiratory resistance, maximal flow at 50 and 75 percent of expired vital capacity, forced expiratory volume in one second and forced vital capacity (FVC). Statistical significance of pulmonary function changes was tested by analysis of covariance for repeated measures. After exposure to 0.12 ppm O3 a significant decrease was seen in maximal flow at 50% of FVC in asthmatic subjects. After exposure to 0.30 ppm NO2 a significant decrease was seen in FVC also in the asthmatic subjects. One possible explanation for these changes is the multiple comparison effect. No significant changes in any parameters were seen in the asthmatic subjects after the combined O3-NO2 exposure or in the healthy subjects after any of the exposures.« less
Ocakli, Birsen; Acarturk, Eylem; Aksoy, Emine; Gungor, Sinem; Ciyiltepe, Fulya; Oztas, Selahattin; Ozmen, Ipek; Agca, Meltem Coban; Salturk, Cuneyt; Adiguzel, Nalan; Karakurt, Zuhal
The aim of this study was to evaluate the impact of exposure to biomass smoke vs cigarette smoke on serum inflammatory markers and pulmonary function parameters in patients with chronic respiratory failure (CRF). A total of 106 patients with CRF divided into age and gender-matched groups of cigarette-smoke exposure (n=55, mean [SD] age: 71.0 [12.0] years, 92.7% were females) and biomass smoke exposure (n=51, mean [SD] age: 73.0 [11.0] years, 94.1% were females) were included in this retrospective study. Data on patient demographics (age and gender), inflammatory markers, including neutrophil-to-lymphocyte ratio, C-reactive protein, platelet/mean platelet volume ratio, arterial blood gas analysis, and pulmonary function test findings, including forced expiratory volume in 1 second (FEV 1 ), forced vital capacity (FVC), and FEV 1 /FVC were obtained from medical records. Carbon dioxide partial pressure levels were significantly higher in the biomass smoke exposure than in the cigarette smoke exposure group (mean [SD] 51.0 [8.0] vs 47.0 [8.0] mmHg, p =0.026, respectively). Spirometry revealed similarly low levels for FEV 1 (%) (38.0 [16.0] vs 40.0 [12.0]%) and FVC (%) (45.0 [19.0] vs 39.0 [19.0]%) in cigarette-smoke and biomass smoke exposure groups, whereas biomass smoke exposure was associated with significantly higher FEV 1 /FVC (75.0 [14.0] vs 58.0 [12.0]%, p =0.001), lower FVC (mL) (mean [SD] 744.0 [410.0] vs 1,063.0 [592.0] mL, p =0.035) and lower percentage of patients with FEV 1 /FVC <70% (36.8% vs 82.0%, p <0.001) than cigarette smoke exposure. Our findings indicate similarly increased inflammatory markers and abnormally low pulmonary function test findings in both biomass smoke exposure and cigarette smoke exposure groups, emphasizing the adverse effects of biomass smoke exposure on lungs to be as significant as cigarette smoke exposure. Association of biomass smoke exposure with higher likelihood of FEV 1 /FVC ratio of >70% and more prominent loss of vital capacity than cigarette smoke exposure seems to indicate the likelihood of at least 18 years of biomass exposure to be sufficiently high to be responsible for both obstructive and restrictive pulmonary diseases.
Manning, Casey M; Johnston, Carl J; Hernady, Eric; Miller, Jen-nie H; Reed, Christina K; Lawrence, B Paige; Williams, Jacqueline P; Finkelstein, Jacob N
2013-06-01
Viral infections have been associated with exacerbation of disease in human cases of idiopathic pulmonary fibrosis. Since pulmonary fibrosis is a common outcome after irradiation to the lung, we hypothesized that viral infection after radiation exposure would exacerbate radiation-induced lung injury. Epithelial injury, a frequent outcome after infection, has been hypothesized to contribute to the pathogenesis of pulmonary fibrosis and bronchiolar epithelial Clara cells participate in epithelial repair. Therefore, it was further hypothesized that altered responses after irradiation involve the bronchiolar epithelial Clara cells. C57BL/6J or CCSP(-/-) mice were irradiated with 0 (sham), 5, 10 or 15 Gy to the whole thorax. At ten weeks post-irradiation, animals were mock infected or infected with influenza A virus and body weight and survival were monitored. Pulmonary function was assessed by whole-body plethysmography. The Clara cell markers, CCSP and Cyp2f2, were measured in the lung by qRT-PCR, and protein expression was visualized in the lung by immunofluorescence. Following pulmonary function tests, mice were sacrificed and tissues were collected for pathological analysis. In 15 Gy irradiated animals infected with influenza A virus, accelerated respiratory rates, reduced pulmonary function, and exacerbated lung pathology occurred earlier post-irradiation than previously observed after irradiation alone, suggesting infection accelerates the development of radiation injury. After irradiation alone, CCSP and Cyp2f2 mRNA levels were reduced, correlating with reductions in the number of Clara cells lining the airways. When combined with infection, these markers further declined and an apparent delay in recovery of mRNA expression was observed, suggesting that radiation injury leads to a chronic reduction in the number of Clara cells that may potentiate the epithelial injury observed after influenza A virus infection. This novel finding may have considerable therapeutic implications with respect to both thoracic tumor patients and recipients of bone marrow transplants.
Spieth, Peter M; Güldner, Andreas; Uhlig, Christopher; Bluth, Thomas; Kiss, Thomas; Schultz, Marcus J; Pelosi, Paolo; Koch, Thea; Gama de Abreu, Marcelo
2014-05-02
General anesthesia usually requires mechanical ventilation, which is traditionally accomplished with constant tidal volumes in volume- or pressure-controlled modes. Experimental studies suggest that the use of variable tidal volumes (variable ventilation) recruits lung tissue, improves pulmonary function and reduces systemic inflammatory response. However, it is currently not known whether patients undergoing open abdominal surgery might benefit from intraoperative variable ventilation. The PROtective VARiable ventilation trial ('PROVAR') is a single center, randomized controlled trial enrolling 50 patients who are planning for open abdominal surgery expected to last longer than 3 hours. PROVAR compares conventional (non-variable) lung protective ventilation (CV) with variable lung protective ventilation (VV) regarding pulmonary function and inflammatory response. The primary endpoint of the study is the forced vital capacity on the first postoperative day. Secondary endpoints include further lung function tests, plasma cytokine levels, spatial distribution of ventilation assessed by means of electrical impedance tomography and postoperative pulmonary complications. We hypothesize that VV improves lung function and reduces systemic inflammatory response compared to CV in patients receiving mechanical ventilation during general anesthesia for open abdominal surgery longer than 3 hours. PROVAR is the first randomized controlled trial aiming at intra- and postoperative effects of VV on lung function. This study may help to define the role of VV during general anesthesia requiring mechanical ventilation. Clinicaltrials.gov NCT01683578 (registered on September 3 3012).
Laporta, Rosalía; Ussetti, Piedad; Mora, Gema; López, Cristina; Gómez, David; de Pablo, Alicia; Lázaro, M Teresa; Carreño, M Cruz; Ferreiro, M José
2008-08-01
The time at which lung transplantation is indicated is determined by clinical and functional criteria that vary according to the particular disease. The aim of our study was to present the criteria according to which patients were placed on waiting lists for lung transplantation in our hospital. We analyzed retrospectively the clinical characteristics, lung function, heart function, and 6-minute walk test results of patients who had received a lung transplant in our hospital from January 2002 through September 2005. During the study period 100 lung transplants were performed. The mean age of the patients was 45 years (range, 15-67 years) and 57% were men. The diseases that most often led to a lung transplant were chronic obstructive pulmonary disease (COPD) (35%), pulmonary fibrosis (29%), and bronchiectasis (21%). Lung function values differed by disease: mean (SD) forced expiratory volume in 1 second (FEV1) was 20% (11%) and forced vital capacity (FVC) was 37% (15%) in patients with COPD; FEV1 was 41% (15%) and FVC, 40% (17%) in patients with pulmonary fibrosis; and FEV1 was 23% (7%) and FVC, 37% (10%) in patients with bronchiectasis. The patients who received lung transplants in our hospital were in advanced phases of their disease and met the inclusion criteria accepted by the various medical associations when they were placed on the waiting list.
Ronaldson, Sarah J; Dyson, Lisa; Clark, Laura; Hewitt, Catherine E; Torgerson, David J; Cooper, Brendan G; Kearney, Matt; Laughey, William; Raghunath, Raghu; Steele, Lisa; Rhodes, Rebecca; Adamson, Joy
2018-06-01
Early identification of chronic obstructive pulmonary disease (COPD) results in patients receiving appropriate management for their condition at an earlier stage in their disease. The determining the optimal approach to identifying individuals with chronic obstructive pulmonary disease (DOC) study was a case-finding study to enhance early identification of COPD in primary care, which evaluated the diagnostic accuracy of a series of simple lung function tests and symptom-based case-finding questionnaires. Current smokers aged 35 or more were invited to undertake a series of case-finding tools, which comprised lung function tests (specifically, spirometry, microspirometry, peak flow meter, and WheezoMeter) and several case-finding questionnaires. The effectiveness of these tests, individually or in combination, to identify small airways obstruction was evaluated against the gold standard of spirometry, with the quality of spirometry tests assessed by independent overreaders. The study was conducted with general practices in the Yorkshire and Humberside area, in the UK. Six hundred eighty-one individuals met the inclusion criteria, with 444 participants completing their study appointments. A total of 216 (49%) with good-quality spirometry readings were included in the analysis. The most effective case-finding tools were found to be the peak flow meter alone, the peak flow meter plus WheezoMeter, and microspirometry alone. In addition to the main analysis, where the severity of airflow obstruction was based on fixed ratios and percent of predicted values, sensitivity analyses were conducted by using lower limit of normal values. This research informs the choice of test for COPD identification; case-finding by use of the peak flow meter or microspirometer could be used routinely in primary care for suspected COPD patients. Only those testing positive to these tests would move on to full spirometry, thereby reducing unnecessary spirometric testing. © 2018 John Wiley & Sons, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamamoto, Tokihiro, E-mail: toyamamoto@ucdavis.edu; Department of Radiation Oncology, University of California Davis School of Medicine, Sacramento, California; Kabus, Sven
Purpose: 4-dimensional computed tomography (4D-CT)-based pulmonary ventilation imaging is an emerging functional imaging modality. The purpose of this study was to investigate the physiological significance of 4D-CT ventilation imaging by comparison with pulmonary function test (PFT) measurements and single-photon emission CT (SPECT) ventilation images, which are the clinical references for global and regional lung function, respectively. Methods and Materials: In an institutional review board–approved prospective clinical trial, 4D-CT imaging and PFT and/or SPECT ventilation imaging were performed in thoracic cancer patients. Regional ventilation (V{sub 4DCT}) was calculated by deformable image registration of 4D-CT images and quantitative analysis for regional volumemore » change. V{sub 4DCT} defect parameters were compared with the PFT measurements (forced expiratory volume in 1 second (FEV{sub 1}; % predicted) and FEV{sub 1}/forced vital capacity (FVC; %). V{sub 4DCT} was also compared with SPECT ventilation (V{sub SPECT}) to (1) test whether V{sub 4DCT} in V{sub SPECT} defect regions is significantly lower than in nondefect regions by using the 2-tailed t test; (2) to quantify the spatial overlap between V{sub 4DCT} and V{sub SPECT} defect regions with Dice similarity coefficient (DSC); and (3) to test ventral-to-dorsal gradients by using the 2-tailed t test. Results: Of 21 patients enrolled in the study, 18 patients for whom 4D-CT and either PFT or SPECT were acquired were included in the analysis. V{sub 4DCT} defect parameters were found to have significant, moderate correlations with PFT measurements. For example, V{sub 4DCT}{sup HU} defect volume increased significantly with decreasing FEV{sub 1}/FVC (R=−0.65, P<.01). V{sub 4DCT} in V{sub SPECT} defect regions was significantly lower than in nondefect regions (mean V{sub 4DCT}{sup HU} 0.049 vs 0.076, P<.01). The average DSCs for the spatial overlap with SPECT ventilation defect regions were only moderate (V{sub 4DCT}{sup HU}0.39 ± 0.11). Furthermore, ventral-to-dorsal gradients of V{sub 4DCT} were strong (V{sub 4DCT}{sup HU} R{sup 2} = 0.69, P=.08), which was similar to V{sub SPECT} (R{sup 2} = 0.96, P<.01). Conclusions: An 18-patient study demonstrated significant correlations between 4D-CT ventilation and PFT measurements as well as SPECT ventilation, providing evidence toward the validation of 4D-CT ventilation imaging.« less
Fitness and lung function in children with primary ciliary dyskinesia and cystic fibrosis.
Ring, Astrid M; Buchvald, Frederik F; Holgersen, Mathias G; Green, Kent; Nielsen, Kim G
2018-06-01
Peak oxygen uptake (VO 2peak ) is associated with morbidity and mortality in health and disease, and provides important information of global physical health not achieved from standard pulmonary function tests. Primary ciliary dyskinesia (PCD) and cystic fibrosis (CF) are genetically determined diseases involving different basic defects, but both showing impaired mucociliary clearance leading to chronic infections and pulmonary destruction early in life. PCD is generally considered a milder disease than CF and it is hypothesized that children with CF would have consistently lower VO 2peak and pulmonary function than children with PCD. We performed a prospective, observational single-center, clinical cohort study of VO 2peak and pulmonary function in age and gender matched schoolchildren, at two occasions 12 months apart. VO 2peak was persistently (at baseline and after 12 months) and significantly reduced in the 22 patients with PCD (z-score = -0.89 and -1.0) and 24 with CF (z-score = -0.94 and -1.1), included in the study. Abnormal VO 2peak was detected in a larger proportion of children with PCD (≈30%) than CF (≈13%). Moreover, children with PCD exhibited persistently lower FEV 1 (p < 0.0001 at first visit and p = 0.001 at second visit) while FEF 25-75 and FVC differed only at baseline. Indeed, a retrospective analysis comparing lung function over the last year in our entire PCD and CF populations between 6 and 18 years of age, revealed lower values in patients with PCD (FEV 1 z-score, p = 0.0004, FVC z-score p < 0.0001, FEF 25-75 z-score p = 0.008). This is the first report indicating that cardiopulmonary fitness is equally and consistently reduced in both children with PCD and CF along with a consistent lower pulmonary function in PCD compared with CF. A certain reservation for possible selection bias and the small number of patients is necessary. However, increased focus on early diagnosis, evidence-based treatment regimens and close clinical monitoring in PCD are warranted. Copyright © 2018 Elsevier Ltd. All rights reserved.
Pulmonary function in advanced uncomplicated singleton and twin pregnancy.
Siddiqui, Anwar Hasan; Tauheed, Nazia; Ahmad, Aquil; Mohsin, Zehra
2014-01-01
Pregnancy brings about significant changes in respiratory function, as evidenced by alterations in lung volumes and capacities, which are attributable to the mechanical impediment caused by the growing foetus. This study was undertaken in order to identify changes in respiratory function during normal pregnancy and to determine whether such changes are more pronounced in twin pregnancy than in singleton pregnancy. Respiratory function was assessed in 50 women with twin pregnancies and in 50 women with singleton pregnancies (during the third trimester in both groups), as well as in 50 non-pregnant women. We measured the following pulmonary function test parameters: FVC; FEV1; PEF rate; FEV1/FVC ratio; FEF25-75%; and maximal voluntary ventilation. All respiratory parameters except the FEV1/FVC ratio were found to be lower in the pregnant women than in the non-pregnant women. We found no significant differences between women with twin pregnancies and those with singleton pregnancies, in terms of respiratory function. Despite its higher physiological demands, twin pregnancy does not appear to impair respiratory function to any greater degree than does singleton pregnancy.
McEvoy, Cindy T; Milner, Kristin F; Scherman, Ashley J; Schilling, Diane G; Tiller, Christina J; Vuylsteke, Brittany; Shorey-Kendrick, Lyndsey E; Spindel, Eliot R; Schuff, Robert; Mitchell, Julie; Peters, Dawn; Metz, Jill; Haas, David; Jackson, Keith; Tepper, Robert S; Morris, Cynthia D
2017-07-01
Despite strong anti-smoking efforts, at least 12% of American women cannot quit smoking when pregnant resulting in >450,000 smoke-exposed infants born yearly. Smoking during pregnancy is the largest preventable cause of childhood respiratory illness including wheezing and asthma. Recent studies have shown a protective effect of vitamin C supplementation on the lung function of offspring exposed to in utero smoke in a non-human primate model and an initial human trial. Vitamin C to Decrease the Effects of Smoking in Pregnancy on Infant Lung Function (VCSIP) is a randomized, double-blind, placebo-controlled trial to evaluate pulmonary function at 3months of age in infants delivered to pregnant smokers randomized to 500mg/day of vitamin C versus placebo during pregnancy. Secondary aims evaluate the incidence of wheezing through 12months and pulmonary function testing at 12months of age. Women are randomized between 13 and 23weeks gestation from clinical sites in Portland, Oregon at Oregon Health & Science University and PeaceHealth Southwest Medical Center and in Indianapolis, Indiana at Indiana University and Wishard Hospital. Vitamin C supplementation occurs from randomization to delivery. Monthly contact with participants and monitoring of medical records is performed to document medication adherence, changes in smoking and medical history, and adverse events. Pulmonary function testing of offspring occurs at 3 and 12months of age and incidence of wheezing and respiratory illness through 12months is captured via at least quarterly questionnaires. Ancillary studies are investigating the impact of vitamin C on placental blood flow and DNA methylation. Copyright © 2017 Elsevier Inc. All rights reserved.
Pulmonary function test results on 224 parochial schoolchildren collected during and after the Pittsburgh air pollution episode of November 1975 were reanalyzed to determine whether a small subgroup of susceptible children could be defined. Individual regressions of three-quarter...
Code of Federal Regulations, 2013 CFR
2013-04-01
... user of the instrument must have a means of correcting volumes to body temperature saturated with water vapor (BTPS) under conditions of varying ambient spirometer temperatures and barometric pressures. (v...
Code of Federal Regulations, 2014 CFR
2014-04-01
... user of the instrument must have a means of correcting volumes to body temperature saturated with water vapor (BTPS) under conditions of varying ambient spirometer temperatures and barometric pressures. (v...
Code of Federal Regulations, 2012 CFR
2012-04-01
... user of the instrument must have a means of correcting volumes to body temperature saturated with water vapor (BTPS) under conditions of varying ambient spirometer temperatures and barometric pressures. (v...
Khalid, Mohammed; Aljurf, Mahmoud; Saleemi, Sarfraz; Khan, Mohammed Qaseem; Khan, Basha; Ahmed, Shad; Ibrahim, Khalid El Tayeb; Mobeireek, Abdullah; Al Mohareb, Fahad; Chaudhri, Naeem
2013-06-01
Bronchiolitis obliterans syndrome is a significant postallogeneic hematopoietic stem cell transplant problem. Recent data in lung transplant patients suggest an association with gastroesophageal reflux disease and bronchiolitis obliterans syndrome. We studied posthematopoietic stem cell transplant patients with bronchiolitis obliterans syndrome for gastroesophageal reflux disease and its response to a proton pump inhibitor. Seven postallogeneic hematopoietic stem cell transplant patients with bronchiolitis obliterans syndrome were studied. Gastroesophageal reflux disease was assessed by 24-hour pH monitoring with a Bravo catheter-free radio pH capsule. Patients with positive gastroesophageal reflux disease were started on omeprazole. Pretreatment and posttreatment pulmonary function tests were done at 3-month intervals. Of 7 patients, 5 had positive results for gastroesophageal reflux disease (71%). Omeprazole had a disease-stabilizing effect on the patients' pulmonary function tests. Our study shows a significant association between bronchiolitis obliterans syndrome and gastroesophageal reflux disease in postallogeneic hematopoietic stem cell transplant patients. Use of omeprazole may have a disease-stabilizing effect in short-term follow-up.
Outcome of influenza infection managed with oseltamivir in lung transplant recipients.
Ison, Michael G; Sharma, Amita; Shepard, Jo-Anne O; Wain, John C; Ginns, Leo C
2008-03-01
Influenza causes significant morbidity and mortality in lung transplant recipients and likely predisposes to obliterative bronchiolitis. Neuraminidase inhibitors shorten the duration of symptoms and virus shedding and the number of antibiotic-requiring complications in ambulatory immunocompetent patients, although the efficacy of these agents in lung transplant recipients has not been assessed previously. In this study, 9 lung transplant patients who were treated with oseltamivir for influenza infections were identified and analyzed retrospectively. Oseltamivir was well tolerated. Infection resolved in all patients and there were no deaths. Two patients developed pneumonia shortly after their influenza infection and both responded to antibiotic therapy. None of the patients had persistent abnormalities noted on chest imaging and most did not show significant changes on pulmonary function testing. Two patients with the lowest pulmonary function test (PFT) values pre-infection had persistent defects after infection. Oseltamivir is well tolerated in lung transplant recipients and may reduce the risk of complications, although further studies are warranted.
Sreenivas, B Sudha; Sunitha, M S; Nataraj, S M; Dhar, Murali
2012-01-01
Smoking has deleterious effects on Pulmonary Function Test (PFT) parameters; however, evidences about recovery in ex-smokers are ambiguous. Therefore present study was conducted to quantify relative deterioration of PFT parameters and to assess reversibility of the same. A cross-sectional study was conducted on 84 bus-depot workers consisting of equal number of smokers, ex-smokers and non-smokers. PFT observations were obtained using Medspiror following standard methods and precautions. Comparisons among three groups were performed employing one-way ANOVA and post-hoc tests. There were substantial effects of smoking on PFT parameters (deterioration was up-to half). Partial recovery was found in all the parameters of ex-smokers. Frequency and duration of smoking were negatively correlated with some of the parameters. In conclusion, present study has demonstrated considerable deterioration of PFT parameters in smokers and indications of recovery in ex-smokers. Further detailed study with larger sample size and stricter definition of ex-smokers is recommended.
Mehrparvar, A H; Mirmohammadi, S J; Mostaghaci, M; Davari, M H; Hashemi, S H
2013-04-01
Respiratory diseases cause a considerable amount of morbidity and mortality in the world. Pulmonary function tests are important measures for the diagnosis and management of respiratory disorders. Workers in tile and ceramic industry are exposed to high amounts of respiratory pollutants. To identify the changes in spirometric parameters in a 2-year period among tile and ceramic workers in Yazd and compare it with a control group. The study was conducted in 5 tile and ceramic factories selected by cluster sampling between 2009 and 2011 in Yazd, southeastern Iran. Demographic data and spirometric parameters of participants were recorded. Spirometric parameters were significantly reduced during the 2 years. The largest decrease was observed in FVC (≈500 mL) in ball-mill and grinding after 2 years. Decrease in all spirometric parameters was significantly higher in industrial workers than office workers. Respiratory exposure in tile and ceramic industry can significantly affect pulmonary function tests.
Gorbunova, Elena E.; Dalrymple, Nadine A.; Gavrilovskaya, Irina N.
2013-01-01
Abstract Background Hantaviruses in the Americas cause a highly lethal acute pulmonary edema termed hantavirus pulmonary syndrome (HPS). Hantaviruses nonlytically infect microvascular and lymphatic endothelial cells and cause dramatic changes in barrier functions without disrupting the endothelium. Hantaviruses cause changes in the function of infected endothelial cells that normally regulate fluid barrier functions. The endothelium of arteries, veins, and lymphatic vessels are unique and central to the function of vast pulmonary capillary beds that regulate pulmonary fluid accumulation. Results We have found that HPS-causing hantaviruses alter vascular barrier functions of microvascular and lymphatic endothelial cells by altering receptor and signaling pathway responses that serve to permit fluid tissue influx and clear tissue edema. Infection of the endothelium provides several mechanisms for hantaviruses to cause acute pulmonary edema, as well as potential therapeutic targets for reducing the severity of HPS disease. Conclusions Here we discuss interactions of HPS-causing hantaviruses with the endothelium, roles for unique lymphatic endothelial responses in HPS, and therapeutic targeting of the endothelium as a means of reducing the severity of HPS disease. PMID:24024573
Mackow, Erich R; Gorbunova, Elena E; Dalrymple, Nadine A; Gavrilovskaya, Irina N
2013-09-01
Hantaviruses in the Americas cause a highly lethal acute pulmonary edema termed hantavirus pulmonary syndrome (HPS). Hantaviruses nonlytically infect microvascular and lymphatic endothelial cells and cause dramatic changes in barrier functions without disrupting the endothelium. Hantaviruses cause changes in the function of infected endothelial cells that normally regulate fluid barrier functions. The endothelium of arteries, veins, and lymphatic vessels are unique and central to the function of vast pulmonary capillary beds that regulate pulmonary fluid accumulation. We have found that HPS-causing hantaviruses alter vascular barrier functions of microvascular and lymphatic endothelial cells by altering receptor and signaling pathway responses that serve to permit fluid tissue influx and clear tissue edema. Infection of the endothelium provides several mechanisms for hantaviruses to cause acute pulmonary edema, as well as potential therapeutic targets for reducing the severity of HPS disease. Here we discuss interactions of HPS-causing hantaviruses with the endothelium, roles for unique lymphatic endothelial responses in HPS, and therapeutic targeting of the endothelium as a means of reducing the severity of HPS disease.
Liu, Zibing; Geng, Wenye; Jiang, Chuanwei; Zhao, Shujun; Liu, Yong; Zhang, Ying; Qin, Shucun; Li, Chenxu; Zhang, Xinfang; Si, Yanhong
2017-09-01
Chronic obstructive pulmonary disease induced by tobacco smoke has been regarded as a great health problem worldwide. The purpose of this study is to evaluate the protective effect of hydrogen-rich saline, a novel antioxidant, on chronic obstructive pulmonary disease and explore the underlying mechanism. Sprague-Dawley rats were made chronic obstructive pulmonary disease models via tobacco smoke exposure for 12 weeks and the rats were treated with 10 ml/kg hydrogen-rich saline intraperitoneally during the last 4 weeks. Lung function testing indicated hydrogen-rich saline decreased lung airway resistance and increased lung compliance and the ratio of forced expiratory volume in 0.1 s/forced vital capacity in chronic obstructive pulmonary disease rats. Histological analysis revealed that hydrogen-rich saline alleviated morphological impairments of lung in tobacco smoke-induced chronic obstructive pulmonary disease rats. ELISA assay showed hydrogen-rich saline lowered the levels of pro-inflammatory cytokines (IL-8 and IL-6) and anti-inflammatory cytokine IL-10 in bronchoalveolar lavage fluid and serum of chronic obstructive pulmonary disease rats. The content of malondialdehyde in lung tissue and serum was also determined and the data indicated hydrogen-rich saline suppressed oxidative stress reaction. The protein expressions of mucin MUC5C and aquaporin 5 involved in mucus hypersecretion were analyzed by Western blot and ELISA and the data revealed that hydrogen-rich saline down-regulated MUC5AC level in bronchoalveolar lavage fluid and lung tissue and up-regulated aquaporin 5 level in lung tissue of chronic obstructive pulmonary disease rats. In conclusion, these results suggest that administration of hydrogen-rich saline exhibits significant protective effect on chronic obstructive pulmonary disease through alleviating inflammation, reducing oxidative stress and lessening mucus hypersecretion in tobacco smoke-induced chronic obstructive pulmonary disease rats. Impact statement This study was designed to evaluate protective effect of hydrogen-rich saline, a novel antioxidant, on tobacco smoke (TS)-induced chronic obstructive pulmonary disease (COPD) in rats and explore the underlying mechanism. Our results suggest that administration of hydrogen-rich saline improves lung function and alleviates morphological impairments of lung through alleviating inflammation, reducing oxidative stress and lessening mucus hypersecretion in TS-induced COPD rats.
Martínez-Pallí, Graciela; Drake, Britt B; García-Pagán, Joan-Carles; Barberà, Joan-Albert; Arguedas, Miguel R; Rodriguez-Roisin, Robert; Bosch, Jaume; Fallon, Michael B
2005-01-01
AIM: To assess the impact of transjugular intrahepatic portosystemic shunt (TIPS) on pulmonary gas exchange and to evaluate the use of TIPS for the treatment of hepatopulmonary syndrome ( HPS ). METHODS: Seven patients, three of them with advanced HPS, in whom detailed pulmonary function tests were performed before and after TIPS placement at the University of Alabama Hospital and at the Hospital Clinic, Barcelona, were considered. RESULTS: TIPS patency was confirmed by hemodynamic evaluation. No changes in arterial blood gases were observed in the overall subset of patients. Transient arterial oxygenation improvement was observed in only one HPS patient, early after TIPS, but this was not sustained 4 mo later. CONCLUSION: TIPS neither improved nor worsened pulmonary gas exchange in patients with portal hypertension. This data does not support the use of TIPS as a specific treatment for HPS. However, it does reinforce the view that TIPS can be safely performed for the treatment of other complications of portal hypertension in patients with HPS. PMID:16425397
Christou, Helen; Reslan, Ossama M.; Mam, Virak; Tanbe, Alain F.; Vitali, Sally H.; Touma, Marlin; Arons, Elena; Mitsialis, S. Alex; Kourembanas, Stella
2012-01-01
Pulmonary hypertension (PH) is characterized by pulmonary arteriolar remodeling with excessive pulmonary vascular smooth muscle cell (VSMC) proliferation. This results in decreased responsiveness of pulmonary circulation to vasodilator therapies. We have shown that extracellular acidosis inhibits VSMC proliferation and migration in vitro. Here we tested whether induction of nonhypercapnic acidosis in vivo ameliorates PH and the underlying pulmonary vascular remodeling and dysfunction. Adult male Sprague-Dawley rats were exposed to hypoxia (8.5% O2) for 2 wk, or injected subcutaneously with monocrotaline (MCT, 60 mg/kg) to develop PH. Acidosis was induced with NH4Cl (1.5%) in the drinking water 5 days prior to and during the 2 wk of hypoxic exposure (prevention protocol), or after MCT injection from day 21 to 28 (reversal protocol). Right ventricular systolic pressure (RVSP) and Fulton's index were measured, and pulmonary arteriolar remodeling was analyzed. Pulmonary and mesenteric artery contraction to phenylephrine (Phe) and high KCl, and relaxation to acetylcholine (ACh) and sodium nitroprusside (SNP) were examined ex vivo. Hypoxic and MCT-treated rats demonstrated increased RVSP, Fulton's index, and pulmonary arteriolar thickening. In pulmonary arteries of hypoxic and MCT rats there was reduced contraction to Phe and KCl and reduced vasodilation to ACh and SNP. Acidosis prevented hypoxia-induced PH, reversed MCT-induced PH, and resulted in reduction in all indexes of PH including RVSP, Fulton's index, and pulmonary arteriolar remodeling. Pulmonary artery contraction to Phe and KCl was preserved or improved, and relaxation to ACh and SNP was enhanced in NH4Cl-treated PH animals. Acidosis alone did not affect the hemodynamics or pulmonary vascular function. Phe and KCl contraction and ACh and SNP relaxation were not different in mesenteric arteries of all groups. Thus nonhypercapnic acidosis ameliorates experimental PH, attenuates pulmonary arteriolar thickening, and enhances pulmonary vascular responsiveness to vasoconstrictor and vasodilator stimuli. Together with our finding that acidosis decreases VSMC proliferation, the results are consistent with the possibility that nonhypercapnic acidosis promotes differentiation of pulmonary VSMCs to a more contractile phenotype, which may enhance the effectiveness of vasodilator therapies in PH. PMID:22287610
Vootla, Vamshidhar R.; Daniel, Myrta
2015-01-01
Refeeding syndrome is defined as electrolyte and fluid abnormalities that occur in significantly malnourished patients when they are refed orally, enterally, or parenterally. The principal manifestations include hypophosphatemia, hypokalemia, vitamin deficiencies, volume overload and edema. This can affect multiple organ systems, such as the cardiovascular, pulmonary, or neurological systems, secondary to the above-mentioned abnormalities. Rarely, patients may develop gastrointestinal symptoms and show abnormal liver function test results. We report the case of a 52-year-old woman with anorexia nervosa who developed refeeding syndrome and simultaneous elevations of liver function test results, which normalized upon the resolution of the refeeding syndrome. PMID:26351414
D'Andrea, Antonello; Stanziola, Anna; Di Palma, Enza; Martino, Maria; D'Alto, Michele; Dellegrottaglie, Santo; Cocchia, Rosangela; Riegler, Lucia; Betancourt Cordido, Meredyth Vanessa; Lanza, Maurizia; Maglione, Marco; Diana, Veronica; Calabrò, Raffaele; Russo, Maria Giovanna; Vannan, Mani; Bossone, Eduardo
2016-01-01
To elucidate right ventricular (RV) function in patients with idiopathic pulmonary fibrosis (IPF) with and without pulmonary hypertension (PH) and its relation to other features of the disease. Clinical evaluation, standard Doppler echo, Doppler myocardial imaging (DMI), and 2D strain echocardiography (STE) of RV septal and lateral walls were performed in 52 IPF patients (66.5 ± 8.5 years; 27 males) and in 45 age- and sex-comparable controls using a commercial US system (MyLab Alpha, Esaote). Pulmonary artery mean pressure (mPAP) was estimated by standard echo Doppler. RV global longitudinal strain (RV GLS) was calculated by averaging RV local strains. The IPF patients were divided into 2 groups by noninvasive assessment of PH: no PH (mPAP<25 mmHg; 36 pts) and PH (mPAP ≥25 mmHg; 16 pts). Left ventricular diameters and ejection fraction were comparable between controls and IPF, while GLS was impaired in IPF (P < 0.01). RV end-diastolic diameters, wall thickness andmPAP were increased in IPF patients with PH. In addition, pulsed DMI detected in PH IPF impaired myocardial RV early diastolic (Em) peak velocity. Also peak systolic RV strain was reduced in basal and middle RV lateral free walls in IPF, as well as RV GLS (P < 0.0001). The impairment in RV wall strain was more evident when comparing controls with the no PH group than comparing the no PH group with the PH group. By multivariate analysis, independent association of RV strain with both six-minute walking test distance (P < 0.001), mPAP (P < 0.0001), as well as with forced vital capacity (FVC) % (P < 0.005) in IPF patients were observed. Impaired RV diastolic and systolic myocardial function were present even in IPF patients without PH, which indicates an early impact on RV function and structure in patients with IPF. © 2015, Wiley Periodicals, Inc.
Kiykim, Ahmet Alper; Horoz, Mehmet; Ozcan, Turkay; Yildiz, Ibrahim; Sari, Sibel; Genctoy, Gultekin
2010-01-01
Pulmonary hypertension (PHT) increases mortality rate in hemodialysis (HD) patients. Numerous clinical, hemodynamic, and metabolic abnormalities have been suggested to be associated with the development of PHT in HD patients. We aimed to investigate the acute effects of two different dialyzer membranes on pulmonary arterial pressure (PAP) throughout a HD session in maintenance HD patients. Seventy-four HD patients dialyzed through permanent tunneled jugular central venous catheter were enrolled. A first-use cellulose acetate and high-flux polysulfone dialysis membrane were tested using a crossover design. For each membrane, pre- and post-dialysis pulmonary artery pressures were measured echocardiographically. Elevated pulmonary artery pressure was observed in 68.8% of patients (n = 51), whereas mild PHT was observed in 28.3% of patients (n = 21) and moderate PHT in 40.5% (n = 30). Decrease in pulmonary artery pressure following HD procedure performed using high-flux polysulfone membrane was significantly higher than the decrease observed following HD procedure performed using cellulose acetate membrane (p < 0.05). Significant decrease in pulmonary artery pressures was observed only after HD procedures performed using high-flux polysulfone membrane (p < 0.05). Ultrafiltered volume was only significantly correlated with the decrease in pulmonary artery pressure observed after HD procedure performed through high-flux polysulfone membrane (β = 0.411, p < 0.05). PHT seems to be prevalent among HD patients even in the absence of AV fistula and abnormal cardiac functions. Membrane composition seems to be important, which may overwhelm the improving effects of ultrafiltration.
Tian, Xiaocao; Xu, Chunsheng; Wu, Yili; Sun, Jianping; Duan, Haiping; Zhang, Dongfeng; Jiang, Baofa; Pang, Zengchang; Li, Shuxia; Tan, Qihua
2017-02-01
Genetic and environmental influences on predictors of decline in daily functioning, including forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), handgrip, and five-times-sit-to-stand test (FTSST), have not been addressed in the aging Chinese population. We performed classical twin modeling on FEV1, FVC, handgrip, and FTSST in 379 twin pairs (240 MZ and 139 DZ) with median age of 50 years (40-80 years). Data were analyzed by fitting univariate and bivariate twin models to estimate the genetic and environmental influences on these measures of physical function. Heritability was moderate for FEV1, handgrip, and FTSST (55-60%) but insignificant for FVC. Only FVC showed moderate control, with shared environmental factors accounting for about 50% of the total variance. In contrast, all measures of pulmonary function and muscle strength showed modest influences from the unique environment (40-50%). Bivariate analysis showed highly positive genetic correlations between FEV1 and FVC (r G = 1.00), and moderately negative genetic correlations between FTSST and FEV1 (r G = -0.33) and FVC (r G = -0.42). FEV1 and FVC, as well as FEV1 and handgrip, displayed high common environmental correlations (r C = 1.00), and there were moderate correlations between FVC and handgrip (r C = 0.44). FEV1 and FVC showed high unique environmental correlations (r E = 0.76) and low correlations between handgrip and FEV1 (r E = 0.17), FVC (r E = 0.14), and FTSST (r E = -0.13) with positive or negative direction. We conclude that genetic factors contribute significantly to the individual differences in common indicators of daily functioning (FEV1, handgrip, and FTSST). FEV1 and FVC were genetically and environmentally correlated. Pulmonary function and FTSST may share similar sets of genes but in the negative direction. Pulmonary function and muscle strength may have a shared environmental background.
Sleep and pulmonary outcomes for clinical trials of airway plexiform neurofibromas in NF1.
Plotkin, Scott R; Davis, Stephanie D; Robertson, Kent A; Akshintala, Srivandana; Allen, Julian; Fisher, Michael J; Blakeley, Jaishri O; Widemann, Brigitte C; Ferner, Rosalie E; Marcus, Carole L
2016-08-16
Plexiform neurofibromas (PNs) are complex, benign nerve sheath tumors that occur in approximately 25%-50% of individuals with neurofibromatosis type 1 (NF1). PNs that cause airway compromise or pulmonary dysfunction are uncommon but clinically important. Because improvement in sleep quality or airway function represents direct clinical benefit, measures of sleep and pulmonary function may be more meaningful than tumor size as endpoints in therapeutic clinical trials targeting airway PN. The Response Evaluation in Neurofibromatosis and Schwannomatosis functional outcomes group reviewed currently available endpoints for sleep and pulmonary outcomes and developed consensus recommendations for response evaluation in NF clinical trials. For patients with airway PNs, polysomnography, impulse oscillometry, and spirometry should be performed to identify abnormal function that will be targeted by the agent under clinical investigation. The functional group endorsed the use of the apnea hypopnea index (AHI) as the primary sleep endpoint, and pulmonary resistance at 10 Hz (R10) or forced expiratory volume in 1 or 0.75 seconds (FEV1 or FEV0.75) as primary pulmonary endpoints. The group defined minimum changes in AHI, R10, and FEV1 or FEV0.75 for response criteria. Secondary sleep outcomes include desaturation and hypercapnia during sleep and arousal index. Secondary pulmonary outcomes include pulmonary resistance and reactance measurements at 5, 10, and 20 Hz; forced vital capacity; peak expiratory flow; and forced expiratory flows. These recommended sleep and pulmonary evaluations are intended to provide researchers with a standardized set of clinically meaningful endpoints for response evaluation in trials of NF1-related airway PNs. © 2016 American Academy of Neurology.
Sandur, V; Murugesh, M; Banait, V; Rathi, P M; Bhatia, S J; Joshi, J M; Kate, A
2014-01-01
The hypothesis that GER can trigger or exacerbate asthma is supported by several clinical trials that have shown amelioration in asthma symptoms and/or an improvement in pulmonary function after antireflux therapy. To investigate the prevalence of GER in patients with difficult to control asthma and to determine the effect of omeprazole on asthma symptoms, reflux symptoms, pulmonary function and on the requirement of asthma medications. Patients with difficult to control asthma were recruited into the study. All patients underwent esophageal manometry and 24 hour esophageal pH monitoring. Pulmonary function tests were done before and after treatment. The severity of asthma and reflux was assessed by a 1 week pulmonary symptom score(PSS) and reflux symptom score(RSS) respectively before and after treatment. Those who had an abnormal pH study (pH <4 in the distal esophagus for >5% of the time) underwent anti-GER treatment with lifestyle changes, and a proton pump inhibitor (omeprazole 40 mg, bid) for 3 months. Asthma medications were added or deleted based on severity of asthma. Out of 250 asthmatic patients screened, forty patients fulfilled the inclusion criteria. Twenty eight of 40 patients(70%) were diagnosed to have GERD. Of the patients 28 with GER, 8 patients(28.5%) had no reflux symptoms. On 24 hr pH metry, the percentage time pH <4.0 was 10.81 ± 4.72 and 1.11 ± 1.21; Deemester score was 37.65 ± 14.54 and 4.89 ± 6.39 (p-value is 0.0001) in GERD and non-GERD patients respectively.In GERD group, post treatment reflux symptom score(RSS) improved from 22.39 ± 14.99 to 1.04 ± 1.07, pulmonary symptom score(PSS) improved from 27.14 ± 7.49 to 13.82 ± 4.21 and night time asthma symptom score(NASS) improved from 6.71 ± 1.80 to 3.04 ± 1.23 (p-value <0.0001). After treatment, FEV1 and PEFR increased from 1.38 ± 0.57 and 4.14 ± 1.97 to 1.47 ± 0.54 and 5.56 ± 1.72, respectively (p-value 0.00114). PPI therapy improves nocturnal asthma symptoms, daytime asthma symptoms, pulmonary function and decreases requirement of asthma medications in these patients.
Correlation between pulmonary function and brain volume in healthy elderly subjects.
Taki, Yasuyuki; Kinomura, Shigeo; Ebihara, Satoru; Thyreau, Benjamin; Sato, Kazunori; Goto, Ryoi; Kakizaki, Masako; Tsuji, Ichiro; Kawashima, Ryuta; Fukuda, Hiroshi
2013-06-01
Cigarette smoking decreases brain regional gray matter volume and is related to chronic obstructive lung disease (COPD). COPD leads to decreased pulmonary function, which is represented by forced expiratory volume in one second percentage (FEV1.0 %); however, it is unclear if decreased pulmonary function is directly related to brain gray matter volume decline. Because there is a link between COPD and cognitive decline, revealing a direct relationship between pulmonary function and brain structure is important to better understand how pulmonary function affects brain structure and cognitive function. Therefore, the purpose of this study was to analyze whether there were significant correlations between FEV1.0 % and brain regional gray and white matter volumes using brain magnetic resonance (MR) image data from 109 community-dwelling healthy elderly individuals. Brain MR images were processed with voxel-based morphometry using a custom template by applying diffeomorphic anatomical registration using the exponentiated lie algebra procedure. We found a significant positive correlation between the regional white matter volume of the cerebellum and FEV1.0 % after adjusting for age, sex, and intracranial volume. Our results suggest that elderly individuals who have a lower FEV1.0 % have decreased regional white matter volume in the cerebellum. Therefore, preventing decreased pulmonary function is important for cerebellar white matter volume in the healthy elderly population.
Xavier, Vivian Bertoni; Roxo, Renata Spósito; Miorin, Luiz Antônio; Dos Santos Alves, Vera Lúcia; Dos Santos Sens, Yvoty Alves
2015-06-01
Chronic kidney disease (CKD) patients on long-term dialysis present changes in pulmonary function and respiratory muscle strength, negatively influencing physical capacity. To analyze the impact of a continuous positive airway pressure (CPAP) protocol on the respiratory capacity of CKD patients under hemodialysis. A randomized clinical trial was conducted involving 40 CKD patients 19-83 years old divided into two groups: control (n = 20) and CPAP (n = 20). Subjects were assessed on the respiratory muscle function test, maximal respiratory pressures, peak flow and 6-min walk test, at baseline and again at the 2-month follow-up. CPAP group patients were submitted to CPAP protocol (PEEP: 5 cm H2O, flow: 15 L/min, FiO2: 33 %) three times per week during hemodialysis sessions. The CPAP group showed higher forced vital capacity, forced expiratory volume in one second, peak expiratory flow, maximal inspiratory pressure, peak flow, as well as lower systolic blood pressure, heart rate, respiratory rate and Borg scale, in addition to a longer distance travelled on the 6-min walk test, compared with the control group. The introduction of a CPAP protocol during hemodialysis sessions had a positive impact on pulmonary function and physical capacity in CKD patients.
Pulmonary Function in Flight (PuFF) Experiment
NASA Technical Reports Server (NTRS)
2003-01-01
In this International Space Station (ISS) onboard photo, Expedition Six Science Officer Donald R. Pettit works to set up the Pulmonary Function in Flight (PuFF) experiment hardware in the Destiny Laboratory. Expedition Six is the fourth and final crew to perform the PuFF experiment. The PuFF experiment was developed to better understand what effects long term exposure to microgravity may have on the lungs. The focus is on measuring changes in the everness of gas exchange in the lungs, and on detecting changes in respiratory muscle strength. It allows astronauts to measure blood flow through the lungs, the ability of the lung to take up oxygen, and lung volumes. Each PuFF session includes five lung function tests, which involve breathing only cabin air. For each planned extravehicular (EVA) activity, a crew member performs a PuFF test within one week prior to the EVA. Following the EVA, those crew members perform another test to document the effect of exposure of the lungs to the low-pressure environment of the space suits. This experiment utilizes the Gas Analyzer System for Metabolic Analysis Physiology, or GASMAP, located in the Human Research Facility (HRF), along with a variety of other Puff equipment including a manual breathing valve, flow meter, pressure-flow module, pressure and volume calibration syringes, and disposable mouth pieces.
Cardiopulmonary involvement in Fabry's disease.
Koskenvuo, Juha W; Kantola, Ilkka M; Nuutila, Pirjo; Knuuti, Juhani; Parkkola, Riitta; Mononen, Ilkka; Hurme, Saija; Kalliokoski, Riikka; Viikari, Jorma S; Wendelin-Saarenhovi, Maria; Kiviniemi, Tuomas O; Hartiala, Jaakko J
2010-04-01
Fabry's disease is an X-linked lysosomal storage disease caused by deficiency of alpha-galactosidase A enzyme activity. Decreased enzyme activity leads to accumulation of glycosphingolipid in different tissues, including endothelial and smooth-muscle cells and cardiomyocytes. There is controversial data on cardiopulmonary involvement in Fabry's disease, because many reports are based on small and selected populations with Fabry's disease. Furthermore, the aetiology of cardiopulmonary symptoms in Fabry's disease is poorly understood. We studied cardiopulmonary involvement in seventeen patients with Fabry's disease (20-65 years, 6 men) using ECG, bicycle stress, cardiac magnetic resonance imaging, spirometry, diffusing capacity and pulmonary high-resolution computed tomography (HRCT) tests. Cardiopulmonary symptoms were compared to observed parameters in cardiopulmonary tests. Left ventricular hypertrophy (LVH) and reduced exercise capacity are the most apparent cardiac changes in both genders with Fabry's disease. ECG parameters were normal when excluding changes related to LVH. Spirometry showed mild reduction in vital capacity and forced expiratory volume in one second (FEV I), and mean values in diffusing capacity tests were within normal limits. Generally, only slight morphological pulmonary changes were detected using pulmonary HRCT, and they were not associated with changes in pulmonary function. The self-reported amount of pulmonary symptoms associated only with lower ejection fraction (P < 0.001) and longer QRS-duration (P = 0.04) of all measured cardiopulmonary parameters, whereas cardiac symptoms have no statistically significant association with any of these parameters. LVH and reduced exercise capacity are the most apparent cardiopulmonary changes in Fabry's disease but they have only a minor association to cardiopulmonary symptoms.Therefore, routine cardiopulmonary evaluation in Fabry's disease using echocardiography is maybe enough when integrated to counselling for aerobic exercise training.
Tartavoulle, Todd Michael
2015-01-01
Pulmonary hypertension (PH) is a life-limiting chronic disease that presents as an elevated blood pressure in the pulmonary artery. The uncertainty of the disease has a profound effect on relationships, cognitive ability, spirituality, emotions, and exercise ability and can negatively impact health-related quality of life (HRQOL). The purposes of this cross-sectional, predictive, correlational study were (a) to identify relationships among the psychological factors (depression, anxiety, stress), physiological factor (6-Minute Walk Test), situational factor (social support), and HRQOL and (b) to test a structural equation model in which depression, anxiety, stress, social support, and 6-minute walk distance predict HRQOL in adults with PH. A convenience sample of 166 adults between the ages of 21 and 80 years were recruited from the Pulmonary Hypertension Association's 10th International Pulmonary Hypertension Conference and Scientific Sessions in Orlando, Florida, and a PH clinic in southeast Louisiana. Each subject completed 2 questionnaires: the 21-item Depression Anxiety Stress Scale and the Dartmouth Cooperative Functional Assessment Charts. The findings indicated a relationship between depression, stress, anxiety, 6-Minute Walk Test, social support, and HRQOL. The data collected from the adult PH population fit the proposed predictive model for adults with PH HRQOL. However, the researcher was unable to determine the best predictor of HRQOL in adults with PH. The findings indicate depression, anxiety, stress, 6-minute walk distance, and social support play important roles in HRQOL among patients with PH. Advanced practice nursing strategies to increase HRQOL include counseling, psychiatric referrals, psychotherapy, guided imagery, leading support groups, and low-grade resistance training.
Sakurai-Iesato, Yoriko; Kawata, Naoko; Tada, Yuji; Iesato, Ken; Matsuura, Yukiko; Yahaba, Misuzu; Suzuki, Toshio; Ikari, Jun; Yanagawa, Noriyuki; Kasahara, Yasunori; West, James; Tatsumi, Koichiro
2017-01-01
Objective Osteoporosis, which is now recognized as a major comorbidity of chronic obstructive pulmonary disease (COPD), must be diagnosed by appropriate methods. The aims of this study were to clarify the relationships between bone mineral density (BMD) and COPD-related clinical variables and to explore the association of BMD with the updated Global Initiative for Chronic Obstructive Lung Disease (GOLD) classification in men. Methods We enrolled 50 Japanese men with clinically stable COPD who underwent dual-energy X-ray absorptiometry (DEXA), pulmonary function testing, and computerized tomography (CT) and who had completed a questionnaire (COPD assessment test [CAT]). We determined the association between the T-score and other tested parameters and compared the BMD of patients in each GOLD category. Results Twenty-three of the 50 patients (46.0%) were diagnosed with osteopenia, and 7 (14.0%) were diagnosed with osteoporosis. The BMD findings were significantly correlated with the CAT score, forced expiratory volume in 1 second percentage predicted (FEV 1 % predicted), low attenuation volume percentage (LAV%), and percentage of cross-sectional area of small pulmonary vessels (%CSA) on CT images. Notably, the median T-score of the GOLD category D participants was significantly lower than that of the participants in each of the other categories (A [-0.98], B [-1.06], C [-1.05], and D [-2.19], p<0.05). Conclusion Reduced BMD was associated with airflow limitation, extent of radiographic findings, and a poor quality of life (QOL) in patients with COPD. The BMD of GOLD category D patients was the lowest of all of the patients evaluated, and category D patients may benefit from active intervention for osteoporosis.
Sakurai-Iesato, Yoriko; Kawata, Naoko; Tada, Yuji; Iesato, Ken; Matsuura, Yukiko; Yahaba, Misuzu; Suzuki, Toshio; Ikari, Jun; Yanagawa, Noriyuki; Kasahara, Yasunori; West, James; Tatsumi, Koichiro
2017-01-01
Objective Osteoporosis, which is now recognized as a major comorbidity of chronic obstructive pulmonary disease (COPD), must be diagnosed by appropriate methods. The aims of this study were to clarify the relationships between bone mineral density (BMD) and COPD-related clinical variables and to explore the association of BMD with the updated Global Initiative for Chronic Obstructive Lung Disease (GOLD) classification in men. Methods We enrolled 50 Japanese men with clinically stable COPD who underwent dual-energy X-ray absorptiometry (DEXA), pulmonary function testing, and computerized tomography (CT) and who had completed a questionnaire (COPD assessment test [CAT]). We determined the association between the T-score and other tested parameters and compared the BMD of patients in each GOLD category. Results Twenty-three of the 50 patients (46.0%) were diagnosed with osteopenia, and 7 (14.0%) were diagnosed with osteoporosis. The BMD findings were significantly correlated with the CAT score, forced expiratory volume in 1 second percentage predicted (FEV1% predicted), low attenuation volume percentage (LAV%), and percentage of cross-sectional area of small pulmonary vessels (%CSA) on CT images. Notably, the median T-score of the GOLD category D participants was significantly lower than that of the participants in each of the other categories (A [-0.98], B [-1.06], C [-1.05], and D [-2.19], p<0.05). Conclusion Reduced BMD was associated with airflow limitation, extent of radiographic findings, and a poor quality of life (QOL) in patients with COPD. The BMD of GOLD category D patients was the lowest of all of the patients evaluated, and category D patients may benefit from active intervention for osteoporosis. PMID:28717072
Zurkova, Monika; Kolek, Vitezslav; Tomankova, Tereza; Kriegova, Eva
2014-12-01
Patients with pulmonary and pulmonary plus extrapulmonary sarcoidosis differ in symptom severity and health status impairment. To date there is no information on differences in clinical and laboratory parameters between these phenotypes and limited information on extrapulmonary involvement in Czech sarcoidosis patients exists. We therefore compared clinical data (age, gender, organ involvement, lung function tests) and laboratory data (blood counts, bronchoalveolar fluid (BAL) cellular profile, serum levels of CRP, SACE, sIL-2R, neopterin) between patients with newly diagnosed pulmonary sarcoidosis (n=107) and those with pulmonary plus extrapulmonary sarcoidosis (n=54). Extrapulmonary sarcoidosis was diagnosed in 33% of patients, mostly affecting lymph nodes and skin and having hypercalciuria. There was no difference in the prevalence of extrapulmonary sarcoidosis between genders. Patients with extrapulmonary sarcoidosis were older and mostly non-smokers when compared to those with limited pulmonary form. X-ray Stage I and erythema nodosum were less frequent in extrapulmonary disease. Serum levels of CRP, SACE, sIL-2R and neopterin and BAL cellular profile did not differ between both phenotypes. We observed lower platelets, FEV1, VC, and BAL CD19+ in females with extrapulmonary involvement than in those with pulmonary disease. Affected lymph nodes, skin and hypercalciuria were the most common in sarcoidosis patients with extrapulmonary involvement. Pulmonary sarcoidosis did not differ in clinical and routine laboratory parameters from pulmonary plus extrapulmonary sarcoidosis. Observation of low platelets, VC, FEV1 and BAL CD19+ in females with extrapulmonary sarcoidosis needs further verification in larger cohort.
COPD prevalence in a random population survey: a matter of definition.
Shirtcliffe, P; Weatherall, M; Marsh, S; Travers, J; Hansell, A; McNaughton, A; Aldington, S; Muellerova, H; Beasley, R
2007-08-01
A recent American Thoracic Society and European Respiratory Society joint Task Force report recommends using a lower limit of normal (LLN) of forced expiratory volume in one second/forced vital capacity as opposed to a fixed ratio of <0.7 to diagnose airflow obstruction, in order to reduce false positive diagnoses of chronic obstructive pulmonary disease (COPD) as defined by the Global Initiative for Obstructive Lung Disease (GOLD). To date, there is no reliable spirometry-based prevalence data for COPD in New Zealand and the effect of different definitions of airflow obstruction based on post-bronchodilator spirometry is not known. Detailed written questionnaires, full pulmonary function tests (including pre- and post-bronchodilator flow-volume loops) and atopy testing were completed in 749 subjects recruited from a random population sample. The GOLD-defined, age-adjusted prevalence (95% confidence interval) for adults aged >or=40 yrs was 14.2 (11.0-17.0)% compared with an LLN-defined, age-adjusted, post-bronchodilator prevalence in the same group of 9.0 (6.7-11.3)%. The prevalence of chronic obstructive pulmonary disease varied markedly depending on the definition used. Further research using longitudinal rather than cross-sectional data will help decide the preferred approach in chronic obstructive pulmonary disease prevalence surveys.
Gavini, S; Finn, R T; Lo, W-K; Goldberg, H J; Burakoff, R; Feldman, N; Chan, W W
2015-09-01
Gastroesophageal reflux (GER) has been associated with idiopathic pulmonary fibrosis (IPF), although the mechanism remains unclear. Gastroesophageal reflux/microaspiration may lead to lung fibrosis, while increased pulmonary workload may also worsen GER. Comparing the GER profile of IPF patients to chronic obstructive pulmonary disease (COPD) patients with similar lung function may help delineate the role of GER in IPF pathogenesis. This was a retrospective cohort study of IPF and COPD patients undergoing pre-lung transplant multichannel intraluminal impedance and pH study (MII-pH) off acid suppression at a tertiary center in 2008-2014. Patients with prior fundoplication were excluded. Baseline demographics, pulmonary function test, and MII-pH results were recorded. Univariate analyses were performed using Fisher's exact (binary variables) and Student's t (continuous variables) tests. Logistic regression was performed to adjust for potential confounders. A total of 90 subjects (54 IPF, 36 COPD) met inclusion criteria. Compared to COPD, IPF patients had increased total reflux episodes (65.9 vs 46.1, p = 0.02), proximal reflux episodes (30.3 vs 20.3, p = 0.04), and prevalence of abnormal total reflux episodes (38.9% vs 16.7%, p = 0.02). On multivariate analyses, abnormal total reflux episodes (OR: 4.9, p = 0.05) and bolus reflux exposure time (OR: 4, p = 0.04) remained significantly associated with IPF. Abnormal reflux was significantly more prevalent among IPF patients after controlling for lung disease severity. Gastroesophageal reflux/microaspiration likely plays a role in fibrosis in IPF. A significant portion of IPF patients had increased non-acid reflux. Therapies aiming to prevent reflux of gastric contents may be more beneficial than antisecretory medications alone in these patients. © 2015 John Wiley & Sons Ltd.
Hæsum, L K E; Ehlers, L H; Hejlesen, O K
2017-09-01
The association between the use of telehomecare technology and functional health literacy is rather unexplored in the current literature. This relationship could prove important in the future management of chronic diseases, as technology has become a more integrated part of modern healthcare systems. Therefore, the purpose of this study was to explore how the use of telehomecare technology affects the level of functional health literacy over a period of 10 months. Randomized controlled trial. Our sample comprised 116 patients diagnosed with chronic obstructive pulmonary disease. A face-to-face interview and an objective test of functional health literacy were conducted with each patient at baseline and again at follow-up after 10 months. Twenty-six patients were lost to follow-up and thus, providing a total of 47 chronic obstructive pulmonary disease patients in the intervention group and 43 in the control group for this follow-up study. The level of functional health literacy was assessed with the Danish Test of Functional Health Literacy in Adults. The difference from baseline to follow-up, in both the functional health literacy score and the mean response time to the entire Danish Test of Functional Health Literacy in Adults (TOFHLA), was tested for statistical significance between the intervention group and the control group. A significant increase in functional health literacy is observed in both the groups from baseline to follow-up, but there is no statistical difference between groups (P-value = 0.62). A significant increase in the functional health literacy score was observed in both groups, but the findings of this present study provide no information on what causes the increase, so further research is needed to explore the increase in functional health literacy score more thoroughly and establish if the use of telehomecare technology is a part of the explanation. Copyright © 2017 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.
Hamedani, Hooman; Shaghaghi, Hoora; Kadlecek, Stephen J.; Xin, Yi; Han, Biao; Siddiqui, Sarmad; Rajaei, Jennia; Ishii, Masaru; Rossman, Milton; Rizi, Rahim R.
2015-01-01
Purpose To evaluate whether regional alveolar oxygen tension (PAO2) vertical gradients imaged with hyperpolarized 3He can identify smoking-induced pulmonary alterations. To compare these gradients with common clinical measurements including pulmonary function tests, the six minute walk test, and the St. George’s Respiratory Questionnaire. Materials and Methods 8 healthy nonsmokers, 12 asymptomatic smokers, and 7 symptomatic subjects with chronic obstructive pulmonary disease (COPD) underwent two sets of back-to-back PAO2 imaging acquisitions in supine position with two opposite directions (top to bottom and bottom to top), followed by clinically standard pulmonary tests. The whole-lung mean, standard deviation (DPAO2) and vertical gradients of PAO2 along the slices were extracted, and the results were compared with clinically derived metrics. Statistical tests were performed to analyze the differences between cohorts. Results The anterior-posterior vertical gradients and DPAO2 effectively differentiated all three cohorts (p<0.05). The average vertical gradient PAO2 in healthy subjects was −1.03 ± 0.51 Torr/cm toward lower values in the posterior/dependent regions. The directional gradient was absent in smokers (0.36 ± 1.22 Torr/cm) and was in the opposite direction in COPD subjects (2.18 ± 1.54 Torr/cm). The vertical gradients correlated with Smoking History (p=0.004); BMI (p=0.037), PFT metrics (FEV1, p=0.025; and %RV/TLC, p=0.033) and with distance walked in six minutes (p=0.009). Discussion Regional PAO2 data indicate that cigarette smoke induces physiological alterations that are not being detected by the most widely used physiologic tests. PMID:25395184
Park, Ji Hye; Mun, Seyeon; Choi, Dong Phil; Lee, Joo Young; Kim, Hyeon Chang
2017-12-11
Accumulating evidence suggests that high-density lipoprotein (HDL) cholesterol is associated with pulmonary function and pulmonary disorders. The aim of this study was to evaluate the association between HDL cholesterol and pulmonary function in healthy adolescents. This cross-sectional study was based on data collected for the JS High School study. The analysis included 644 adolescents (318 male and 326 female) aged 15-16 years old and free from asthma or chronic obstructive pulmonary disease. Fasting blood samples were collected for hematologic and biochemical assessment. Forced vital capacity volume (FVC) and forced expiratory volume in the 1 s (FEV1) were measured using dry-rolling-seal spirometry. The associations between HDL cholesterol and pulmonary function were analyzed using multiple linear regression models. Among male adolescents, an increase of 1.0 mg/dL in HDL cholesterol was associated with 10 mL decrease in FVC (p = 0.013) and FEV1 (p = 0.013) after adjusting for age, height, weight, alcohol drinking, smoking, physical activity, systolic blood pressure, total cholesterol, triglyceride, and monthly household income. Percent predicted values of FVC (p = 0.036) and FEV1 (p = 0.017) were also inversely associated with HDL cholesterol. However, among female adolescents, HDL cholesterol level was not significantly associated with absolute or percent predictive value of FVC and FEV1. Higher HDL cholesterol level may be associated with decreased pulmonary function among healthy male adolescents. The sex differences observed in the association between HDL cholesterol and pulmonary function need further investigation.
Pan, M M; Zhang, H S; Sun, T Y
2017-05-30
Objective: To evaluate the value of forced expiratory volume in 6 seconds (FEV(6)) in the evaluation of pulmonary function in Chinese elderly males. Methods: Pulmonary function tests of elderly who had received regular physical examination in Beijing Hospital from July 2003 to April 2015 were analyzed on subjects with the following characteristics: aged 60 years or older, completion of bronchial dilation test and able to exhale for at least six seconds. The included subjects were divided into 2 groups: 60-<80 years group and ≥80 years group. The association of FEV(6) with forced vital capacity (FVC), FEV(1)/FEV(6) with FEV(1)/FVC, the diagnostic efficiency and influencing factor of FEV(6) and FEV(1)/FEV(6) were analyzed; the value of FEV(6) in the evaluation of pulmonary function in the study population was evaluated. Results: A total of 475 elderly men aged 60 years or older were enrolled, with a mean age of (77.13±9.53) years. Totally there were 269 subjects in 60-<80 years group, which accounted for 56.6%; 206 subjects were in ≥80 years group, which accounted for 43.4%. There were 292 subjects with irreversible airflow obstruction, accounting for 61.5%. In all the included subjects, FEV(6) was significantly correlated with FVC and post-bronchodilator FEV(1)/FEV(6) was significantly correlated with post-bronchodilator FEV(1)/FVC( r =0.971, 0.978; both P <0.001), which were similar in 60-<80 years group and ≥80 years group ( r =0.967, 0.974 and r =0.955, 0.967; all P <0.001). FEV(1)/FEV(6) showed excellent accuracy in diagnosing airflow obstruction[area under curve (AUC)=0.990(95% CI: 0.983-0.996); P <0.001]. Using FEV(1)/FVC<0.70 as a reference, FEV(1)/FEV(6)<0.73 had the best sensitivity (0.952) and specificity (0.945), and there was excellent agreement between the two diagnostic cutoffs (κ=0.891; P <0.001). When difference between before and after bronchial dilation test was analyzed, no correlation was observed between FEV(6) improvement and the improvement of forced expiratory time ( r =0.089; P =0.053), but FVC improvement was significantly correlated with the improvement of forced expiratory time ( r =0.460; P <0.001). Similar results were also found in subjects with irreversible airflow obstruction. Subjects with FEV(1)/FEV(6)≥0.70 and FEV(1)/FVC<0.70 were categorized as pulmonary function middle group, a total of 73 cases, which included 20 cases ≥80 years old. The proportion of middle group among ≥80 years group was significantly less than that of the 60-<80 years group (χ(2)=8.958; P =0.003). In pulmonary function middle group, FEV(1)/FEV(6) or FEV(1)/FVC had no correlation with inspiratory capacity or residual volume/total lung capacity (all P >0.05). Conclusions: FEV(6) and FEV(1)/FEV(6) are strongly correlated with FVC and FEV(1)/FVC, and there is excellent agreement between FEV(1)/FEV(6) and FEV(1)/FVC. FEV(6) is simple, easy to operate and with less influencing factors, which can be used as a valid alternative for FVC in diagnosing airflow obstruction in elderly males.
Regulation of pulmonary inflammation by mesenchymal cells.
Alkhouri, Hatem; Poppinga, Wilfred Jelco; Tania, Navessa Padma; Ammit, Alaina; Schuliga, Michael
2014-12-01
Pulmonary inflammation and tissue remodelling are common elements of chronic respiratory diseases such as asthma, chronic obstructive pulmonary disease (COPD), idiopathic pulmonary fibrosis (IPF), and pulmonary hypertension (PH). In disease, pulmonary mesenchymal cells not only contribute to tissue remodelling, but also have an important role in pulmonary inflammation. This review will describe the immunomodulatory functions of pulmonary mesenchymal cells, such as airway smooth muscle (ASM) cells and lung fibroblasts, in chronic respiratory disease. An important theme of the review is that pulmonary mesenchymal cells not only respond to inflammatory mediators, but also produce their own mediators, whether pro-inflammatory or pro-resolving, which influence the quantity and quality of the lung immune response. The notion that defective pro-inflammatory or pro-resolving signalling in these cells potentially contributes to disease progression is also discussed. Finally, the concept of specifically targeting pulmonary mesenchymal cell immunomodulatory function to improve therapeutic control of chronic respiratory disease is considered. Copyright © 2014 Elsevier Ltd. All rights reserved.
Effects of copper nanoparticle exposure on host defense in a murine pulmonary infection model
2011-01-01
Background Human exposure to nanoparticles (NPs) and environmental bacteria can occur simultaneously. NPs induce inflammatory responses and oxidative stress but may also have immune-suppressive effects, impairing macrophage function and altering epithelial barrier functions. The purpose of this study was to assess the potential pulmonary effects of inhalation and instillation exposure to copper (Cu) NPs using a model of lung inflammation and host defense. Methods We used Klebsiella pneumoniae (K.p.) in a murine lung infection model to determine if pulmonary bacterial clearance is enhanced or impaired by Cu NP exposure. Two different exposure modes were tested: sub-acute inhalation (4 hr/day, 5 d/week for 2 weeks, 3.5 mg/m3) and intratracheal instillation (24 hr post-exposure, 3, 35, and 100 μg/mouse). Pulmonary responses were evaluated by lung histopathology plus measurement of differential cell counts, total protein, lactate dehydrogenase (LDH) activity, and inflammatory cytokines in bronchoalveolar lavage (BAL) fluid. Results Cu NP exposure induced inflammatory responses with increased recruitment of total cells and neutrophils to the lungs as well as increased total protein and LDH activity in BAL fluid. Both inhalation and instillation exposure to Cu NPs significantly decreased the pulmonary clearance of K.p.-exposed mice measured 24 hr after bacterial infection following Cu NP exposure versus sham-exposed mice also challenged with K.p (1.4 × 105 bacteria/mouse). Conclusions Cu NP exposure impaired host defense against bacterial lung infections and induced a dose-dependent decrease in bacterial clearance in which even our lowest dose demonstrated significantly lower clearance than observed in sham-exposed mice. Thus, exposure to Cu NPs may increase the risk of pulmonary infection. PMID:21943386
Avouac, Jérôme; Huscher, Dörte; Furst, Daniel E; Opitz, Christian F; Distler, Oliver; Allanore, Yannick
2014-01-01
To establish an expert consensus on which criteria are the most appropriate in clinical practice to refer patients with systemic sclerosis (SSc) for right heart catheterisation (RHC) when pulmonary hypertension (PH) is suspected. A three stage internet based Delphi consensus exercise involving worldwide PH experts was designed. In the first stage, a comprehensive list of domains and items combining evidence based indications and expert opinions were obtained. In the second and third stages, experts were asked to rate each item selected in the list. After each of stages 2 and 3, the number of items and criteria were reduced according to a cluster analysis. A literature search and the opinions of 47 experts participating in Delphi stage 1 provided a list of seven domains containing 142 criteria. After stages 2 and 3, these domains and tools were reduced to three domains containing eight tools: clinical (progressive dyspnoea over the past 3 months, unexplained dyspnoea, worsening of WHO dyspnoea functional class, any finding on physical examination suggestive of elevated right heart pressures and any sign of right heart failure), echocardiography (systolic pulmonary artery pressure >45 mm Hg and right ventricle dilation) and pulmonary function tests (diffusion lung capacity for carbon monoxide <50% without pulmonary fibrosis). Among experts in pulmonary arterial hypertension-SSc, a core set of criteria for clinical practice to refer SSc patients for RHC has been defined by Delphi consensus methods. Although these indications are recommended by this expert group to be used as an interim tool, it will be necessary to formally validate the present tools in further studies.
The effects of obesity on lung volumes and oxygenation.
Littleton, Stephen W; Tulaimat, Aiman
2017-03-01
Obesity can cause hypoxemia by decreasing lung volumes to where there is closure of lung units during normal breathing. Studies describing this phenomenon are difficult to translate into clinical practice. We wanted to determine the lung volume measurements that are associated with hypoxemia in obese patients, and explore how we could use these measurements to identify them. We collected pulmonary function test results and arterial blood gas data on 118 patients without obstruction on pulmonary function testing. We included only patients with normal chest imaging and cardiac testing within one year of the pulmonary function test, to exclude other causes of hypoxemia. We found that as BMI increases, the mean paO 2 , ERV % predicted, and ERV/TLC decrease (BMI 20-30 kg/m 2 : paO 2 =90±8 mmHg, ERV% predicted 112±50, ERV/TLC (%) 19.7±6.5; BMI 30-40 kg/m 2 : paO 2 =84±10 mmHg, ERV% predicted 84±40 ERV/TLC(%) 13.6±7.6; BMI>40 kg/m 2 : paO 2 78 ±12 mmHg, ERV% predicted 64±27 ERV/TLC(%) 11.4±5.8, ANOVA p<0.001). The A-a gradient increases as BMI increases (r=0.42, p<0.001). This correlation was stronger in men (r=0.54) than in women (r=0.35). The paO 2 is lower in patients with a low ERV than in those with a normal ERV (p<0.001). In a multivariate linear regression, only the ERV/TLC predicted (%), age, and BMI were associated with oxygenation (r 2 for A-a gradient =0.28, p=0.036). In obese patients without cardiopulmonary disease, oxygen levels decrease as BMI increases. This effect is associated with the obesity-related reduction in ERV and is independent of hypoventilation. Published by Elsevier Ltd.
Tenth anniversary special issue of the Journal of Breath Research: looking forward
The Journal of Breath Research has now reached its 10th anniversary of publication. From the general public’s perspective, breath analysis had always revolved around drinking and driving, and to some lesser extent pulmonary function testing of athletes. However, at the ince...
21 CFR 868.1840 - Diagnostic spirometer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Diagnostic spirometer. 868.1840 Section 868.1840...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1840 Diagnostic spirometer. (a) Identification. A diagnostic spirometer is a device used in pulmonary function testing to measure the volume of...
Redente, Elizabeth F.; Keith, Rebecca C.; Janssen, William; Henson, Peter M.; Ortiz, Luis A.; Downey, Gregory P.; Bratton, Donna L.
2014-01-01
Idiopathic pulmonary fibrosis (IPF) is a relentless, fibrotic parenchymal lung disease in which alternatively programmed macrophages produce profibrotic molecules that promote myofibroblast survival and collagen synthesis. Effective therapies to treat patients with IPF are lacking, and conventional therapy may be harmful. We tested the hypothesis that therapeutic lung delivery of the proinflammatory cytokine tumor necrosis factor (TNF)-α into wild-type fibrotic mice would reduce the profibrotic milieu and accelerate the resolution of established pulmonary fibrosis. Fibrosis was assessed in bleomycin-instilled wild-type and TNF-α−/− mice by measuring hydroxyproline levels, static compliance, and Masson’s trichrome staining. Macrophage infiltration and programming status was assessed by flow cytometry of enzymatically digested lung and in situ immunostaining. Pulmonary delivery of TNF-α to wild-type mice with established pulmonary fibrosis was found to reduce their fibrotic burden, to improve lung function and architecture, and to reduce the number and programming status of profibrotic alternatively programmed macrophages. In contrast, fibrosis and alternative macrophage programming were prolonged in bleomycin-instilled TNF-α−/− mice. To address the role of the reduced numbers of alternatively programmed macrophages in the TNF-α–induced resolution of established pulmonary fibrosis, we conditionally depleted macrophages in MAFIA (MAcrophage Fas-Induced Apoptosis) mice. Conditional macrophage depletion phenocopied the resolution of established pulmonary fibrosis observed after therapeutic TNF-α delivery. Taken together, our results show for the first time that TNF-α is involved in the resolution of established pulmonary fibrosis via a mechanism involving reduced numbers and programming status of profibrotic macrophages. We speculate that pulmonary delivery of TNF-α or augmenting its signaling pathway represent a novel therapeutic strategy to resolve established pulmonary fibrosis. PMID:24325577
Redente, Elizabeth F; Keith, Rebecca C; Janssen, William; Henson, Peter M; Ortiz, Luis A; Downey, Gregory P; Bratton, Donna L; Riches, David W H
2014-04-01
Idiopathic pulmonary fibrosis (IPF) is a relentless, fibrotic parenchymal lung disease in which alternatively programmed macrophages produce profibrotic molecules that promote myofibroblast survival and collagen synthesis. Effective therapies to treat patients with IPF are lacking, and conventional therapy may be harmful. We tested the hypothesis that therapeutic lung delivery of the proinflammatory cytokine tumor necrosis factor (TNF)-α into wild-type fibrotic mice would reduce the profibrotic milieu and accelerate the resolution of established pulmonary fibrosis. Fibrosis was assessed in bleomycin-instilled wild-type and TNF-α(-/-) mice by measuring hydroxyproline levels, static compliance, and Masson's trichrome staining. Macrophage infiltration and programming status was assessed by flow cytometry of enzymatically digested lung and in situ immunostaining. Pulmonary delivery of TNF-α to wild-type mice with established pulmonary fibrosis was found to reduce their fibrotic burden, to improve lung function and architecture, and to reduce the number and programming status of profibrotic alternatively programmed macrophages. In contrast, fibrosis and alternative macrophage programming were prolonged in bleomycin-instilled TNF-α(-/-) mice. To address the role of the reduced numbers of alternatively programmed macrophages in the TNF-α-induced resolution of established pulmonary fibrosis, we conditionally depleted macrophages in MAFIA (MAcrophage Fas-Induced Apoptosis) mice. Conditional macrophage depletion phenocopied the resolution of established pulmonary fibrosis observed after therapeutic TNF-α delivery. Taken together, our results show for the first time that TNF-α is involved in the resolution of established pulmonary fibrosis via a mechanism involving reduced numbers and programming status of profibrotic macrophages. We speculate that pulmonary delivery of TNF-α or augmenting its signaling pathway represent a novel therapeutic strategy to resolve established pulmonary fibrosis.
Danielsson, Aina J; Ekerljung, Linda; Hallerman, Kerstin Lofdahl
2015-09-01
Consecutive patients with idiopathic scoliosis diagnosed before age 10 attended a clinical follow-up at least 10 years after treatment. To evaluate the pulmonary function in adulthood after treatment with brace or surgery before maturity. Long-term studies of these patients have not been published. One hundred twenty-four patients (69% of the original group) underwent radiography, spirometry, and answered symptom questionnaires. A total of 73 patients had spirometries before treatment enabling longitudinal evaluation. Overall, 68 braced only (BT) and 56 surgically treated (ST) were analyzed in detail. A population-based control group was used. At follow-up, the mean age was 41.5 years and the mean curve size 36 degrees (26% of the curves >45 degrees). The full patient group had a significantly reduced pulmonary function (as measured by the forced vital capacity [FVC], percentage of predicted) compared with the control group, mean 85% versus 102% (p < .0001). Both subgroups of BT and ST patients showed a significant reduction, more in the ST than the BT group (means 79% and 90%, respectively, p = .0003). The most important risk factor for a low lung function at follow-up was a low initial FVC value. Initial curve size correlated with pulmonary function both before treatment and at follow-up. Most surgically treated patients, who had larger curves before treatment, did not improve their pulmonary function after surgery. Both braced and surgically treated patients had reduced pulmonary function at the age of around 40 years. The pulmonary function did not worsen over time in most patients. There was no difference in terms of symptoms between patient groups and controls. Initial curve size was found to be of great importance for pulmonary function. Initial spirometry and follow-up in selected patients is important. III. Copyright © 2015 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.