21 CFR 868.1890 - Predictive pulmonary-function value calculator.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Predictive pulmonary-function value calculator. 868.1890 Section 868.1890 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... pulmonary-function value calculator. (a) Identification. A predictive pulmonary-function value calculator is...
21 CFR 868.1890 - Predictive pulmonary-function value calculator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Predictive pulmonary-function value calculator. 868.1890 Section 868.1890 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... pulmonary-function value calculator. (a) Identification. A predictive pulmonary-function value calculator is...
Ueda, Kazuhiro; Tanaka, Toshiki; Li, Tao-Sheng; Tanaka, Nobuyuki; Hamano, Kimikazu
2009-03-01
The prediction of pulmonary functional reserve is mandatory in therapeutic decision-making for patients with resectable lung cancer, especially those with underlying lung disease. Volumetric analysis in combination with densitometric analysis of the affected lung lobe or segment with quantitative computed tomography (CT) helps to identify residual pulmonary function, although the utility of this modality needs investigation. The subjects of this prospective study were 30 patients with resectable lung cancer. A three-dimensional CT lung model was created with voxels representing normal lung attenuation (-600 to -910 Hounsfield units). Residual pulmonary function was predicted by drawing a boundary line between the lung to be preserved and that to be resected, directly on the lung model. The predicted values were correlated with the postoperative measured values. The predicted and measured values corresponded well (r=0.89, p<0.001). Although the predicted values corresponded with values predicted by simple calculation using a segment-counting method (r=0.98), there were two outliers whose pulmonary functional reserves were predicted more accurately by CT than by segment counting. The measured pulmonary functional reserves were significantly higher than the predicted values in patients with extensive emphysematous areas (<-910 Hounsfield units), but not in patients with chronic obstructive pulmonary disease. Quantitative CT yielded accurate prediction of functional reserve after lung cancer surgery and helped to identify patients whose functional reserves are likely to be underestimated. Hence, this modality should be utilized for patients with marginal pulmonary function.
Obstructive lung disease as a complication in post pulmonary TB
NASA Astrophysics Data System (ADS)
Tarigan, A. P.; Pandia, P.; Eyanoer, P.; Tina, D.; Pratama, R.; Fresia, A.; Tamara; Silvanna
2018-03-01
The case of post TB is a problem that arises in the community. Pulmonary tuberculosis (TB) can affect lung function. Therefore, we evaluated impaired pulmonary function in subjects with diagnosed prior pulmonary TB. A Case Series study, pulmonary function test was performed in subjects with a history of pulmonary tuberculosis; aged ≥18 years were included. Exclusion criteria was a subject who had asthma, obesity, abnormal thorax and smoking history. We measured FEV1 and FVC to evaluate pulmonary function. Airflow obstruction was FEV1/FVC%<75 and restriction was FVC<80% according to Indonesia’s pneumomobile project. This study was obtained from 23 patients with post pulmonary TB, 5 subjects (23%) had airflow obstruction with FEV1/FVC% value <75%, 15 subjects (71.4%) had abnormalities restriction with FVC value <80% and 3 subjects (5.6%) had normal lung function. Obstructive lung disease is one of the complications of impaired lung function in post pulmonary TB.
Kobayashi, Keisuke; Saeki, Yusuke; Kitazawa, Shinsuke; Kobayashi, Naohiro; Kikuchi, Shinji; Goto, Yukinobu; Sakai, Mitsuaki; Sato, Yukio
2017-11-01
It is important to accurately predict the patient's postoperative pulmonary function. The aim of this study was to compare the accuracy of predictions of the postoperative residual pulmonary function obtained with three-dimensional computed tomographic (3D-CT) volumetry with that of predictions obtained with the conventional segment-counting method. Fifty-three patients scheduled to undergo lung cancer resection, pulmonary function tests, and computed tomography were enrolled in this study. The postoperative residual pulmonary function was predicted based on the segment-counting and 3D-CT volumetry methods. The predicted postoperative values were compared with the results of postoperative pulmonary function tests. Regarding the linear correlation coefficients between the predicted postoperative values and the measured values, those obtained using the 3D-CT volumetry method tended to be higher than those acquired using the segment-counting method. In addition, the variations between the predicted and measured values were smaller with the 3D-CT volumetry method than with the segment-counting method. These results were more obvious in COPD patients than in non-COPD patients. Our findings suggested that the 3D-CT volumetry was able to predict the residual pulmonary function more accurately than the segment-counting method, especially in patients with COPD. This method might lead to the selection of appropriate candidates for surgery among patients with a marginal pulmonary function.
Pulmonary function tests correlated with thoracic volumes in adolescent idiopathic scoliosis.
Ledonio, Charles Gerald T; Rosenstein, Benjamin E; Johnston, Charles E; Regelmann, Warren E; Nuckley, David J; Polly, David W
2017-01-01
Scoliosis deformity has been linked with deleterious changes in the thoracic cavity that affect pulmonary function. The causal relationship between spinal deformity and pulmonary function has yet to be fully defined. It has been hypothesized that deformity correction improves pulmonary function by restoring both respiratory muscle efficiency and increasing the space available to the lungs. This research aims to correlate pulmonary function and thoracic volume before and after scoliosis correction. Retrospective correlational analysis between thoracic volume modeling from plain x-rays and pulmonary function tests was conducted. Adolescent idiopathic scoliosis patients enrolled in a multicenter database were sorted by pre-operative Total Lung Capacities (TLC) % predicted values from their Pulmonary Function Tests (PFT). Ten patients with the best and ten patients with the worst TLC values were included. Modeled thoracic volume and TLC values were compared before and 2 years after surgery. Scoliosis correction resulted in an increase in the thoracic volume for patients with the worst initial TLCs (11.7%) and those with the best initial TLCs (12.5%). The adolescents with the most severe pulmonary restriction prior to surgery strongly correlated with post-operative change in total lung capacity and thoracic volume (r 2 = 0.839; p < 0.001). The mean increase in thoracic volume in this group was 373.1 cm 3 (11.7%) which correlated with a 21.2% improvement in TLC. Scoliosis correction in adolescents was found to increase thoracic volume and is strongly correlated with improved TLC in cases with severe restrictive pulmonary function, but no correlation was found in cases with normal pulmonary function. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:175-182, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
21 CFR 868.1880 - Pulmonary-function data calculator.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pulmonary-function data calculator. 868.1880 Section 868.1880 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...-function values based on actual physical data obtained during pulmonary-function testing. (b...
21 CFR 868.1880 - Pulmonary-function data calculator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pulmonary-function data calculator. 868.1880 Section 868.1880 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...-function values based on actual physical data obtained during pulmonary-function testing. (b...
Ohno, Yoshiharu; Nishio, Mizuho; Koyama, Hisanobu; Takenaka, Daisuke; Takahashi, Masaya; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Obara, Makoto; van Cauteren, Marc; Sugimura, Kazuro
2013-08-01
To evaluate the utility of pulmonary magnetic resonance (MR) imaging with ultra-short echo times (UTEs) at a 3.0 T MR system for pulmonary functional loss and disease severity assessments of connective tissue disease (CTD) patients with interstitial lung disease (ILD). This prospective study was approved by the institutional review board, and written informed consent was obtained from 18 CTD patients (eight men and ten women) and eight normal subjects with suspected chest disease (three men and five women). All subjects underwent thin-section MDCT, pulmonary MR imaging with UTEs, pulmonary function test and serum KL-6. Regional T2 maps were generated from each MR data set, and mean T2 values were determined from ROI measurements. From each thin-section MDCT data set, CT-based disease severity was evaluated with a visual scoring system. Mean T2 values for normal and CTD subjects were statistically compared by using Student's t-test. To assess capability for pulmonary functional loss and disease severity assessments, mean T2 values were statistically correlated with pulmonary functional parameters, serum KL-6 and CT-based disease severity. Mean T2 values for normal and CTD subjects were significantly different (p=0.0019) and showed significant correlations with %VC, %DLCO, serum KL-6 and CT-based disease severity of CTD patients (p<0.05). Pulmonary MR imaging with UTEs is useful for pulmonary functional loss and disease severity assessments of CTD patients with ILD. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
21 CFR 868.1900 - Diagnostic pulmonary-function interpretation calculator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Diagnostic pulmonary-function interpretation calculator. 868.1900 Section 868.1900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... pulmonary-function values. (b) Classification. Class II (performance standards). ...
21 CFR 868.1900 - Diagnostic pulmonary-function interpretation calculator.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Diagnostic pulmonary-function interpretation calculator. 868.1900 Section 868.1900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... pulmonary-function values. (b) Classification. Class II (performance standards). ...
Pulmonary functions in tannery workers--a cross sectional study.
Chandrasekaran, Vasanthi; Dilara, K; Padmavathi, R
2014-01-01
Tannery workers are at potential exposure to detrimental agents rendering them vulnerable to respiratory and dermal problems. Thus by performing pulmonary functions among leather tannery workers, we can decipher the effect of chromium and leather dust on lung functions and also the decline of respiratory functions with increasing years of exposure to leather dust. Pulmonary functions were assessed for 130 tannery workers and compared with the 130 unexposed office workers. Pulmonary function measurements namely FVC, FEV1, FEF25-75% and PEFR were measured using portable data logging Spirometer (KOKO Spirometer). The observed pulmonary functions of Tannery-workers in this study showed a reduction in FEV1, FVC, FEV1/FVC ratio, FEF25-75 and PEFR in relation to their predicted values and also compared to the unexposed. Smokers showed a decline in pulmonary functions compared to the non smokers because smoking acts as an additional risk factor in the development of respiratory illnesses. It is worthy to mention that the pulmonary function values correlate negatively with the duration of exposure to leather dust. So this study could provide base line information based upon which legal implementation of preventive measures could be undertaken.
Hassan, Megahed M; Hussein, Mona T; Emam, Ahmed Mamdouh; Rashad, Usama M; Rezk, Ibrahim; Awad, Al Hussein
2018-08-01
Optimal pulmonary air support is essential pre-requisite for efficient phonation. The objective is to correlate pulmonary and vocal functions in chronic obstructive pulmonary disease (COPD) to find out whether the reduced pulmonary function per se could induce dysphonia. In this prospective case-control study, sixty subjects with stable COPD underwent evaluation of pulmonary and vocal functions. The pulmonary functions measured include {Forced vital capacity (FVC), forced expiratory volume in the first second (FEV1), FEV1/FVC ratio, peak expiratory flow (PEF), maximum mid-expiratory flow (MMEF)}. The vocal functions were {jitter, shimmer, noise-to-harmonic ratio, pitch perturbation quotient, amplitude perturbation quotient, maximum phonation time (MPT), sound pressure level, phonatory efficiency, resistance and power. A control group (n=35) underwent the same measurements. These functions were compared between subjects and controls. Also, correlation of the vocal and pulmonary functions was conducted. Thirty five (58.3%) of COPD subjects have dysphonia. The pulmonary functions were lower in all COPD group than in the control group (P<0.001 for all parameters). Also, the FVC, FEV1, PEF and MMEF % of predicted values were significantly lower in subjects with dysphonia (n=35) than those without dysphonia (n=25) with P values 0.0018, <0.001, 0.0011 and 0.0026 respectively. In addition, the MPT in all subjects showed positive correlations to the 5 pulmonary functions (P=0.004 for FEV1/FVC ratio and P<0.001 for the rest). Also, the phonatory efficiency showed significant positive correlations with the pulmonary functions FVC, FEV1, PEF and MMEF (P=0.001, 0.001, 0.002 and 0.001 respectively). Unlike efficiency, the phonatory resistance revealed significant negative correlations with these pulmonary functions in the same order (P=0.001, 0.003, 0.002, 0.001 respectively). Dysphonia is a common comorbidity with COPD which attributed to multifactorial etiologies. The lower the pulmonary function in COPD patients is the more likely to have dysphonia. Decreased pulmonary function was associated with reduced MPT and phonatory efficiency but with increased phonatory resistance. The reduced pulmonary functions in COPD can be the underlying cause of the altered vocal function and dysphonia. Great part of this dysphonia is functional, and hence, can be corrected by voice therapy in compensated subjects. Further researches are needed to evaluate the efficacy of voice therapy in these patients. Copyright © 2017 Elsevier B.V. All rights reserved.
[The repercussions of pulmonary congestion on ventilatory volumes, capacities and flows].
Carmo, M M; Ferreira, T; Lousada, N; Bárbara, C; Neves, P R; Correia, J M; Rendas, A B
1994-10-01
To evaluate the effects of pulmonary congestion on pulmonary function. Prospective study performed in patients with left ventricular failure or mitral stenosis. Forty-eight hospitalized patients were included suffering from pulmonary congestion either from left ventricular failure or mitral stenosis. While in hospital all patients were submitted to right heart catheterization by the Swan-Ganz method and also to an echocardiographic examination. Within 48 hours after the patients were submitted to the following lung function studies: lung volumes and capacities by the multi-breath helium dilution method and airway flows by pneumotachography. Respiratory symptoms were evaluated by the Medical Research Council Questionnaire and the functional class classified according to the NYHA. Correlations were made between the functional and clinical data. Regarding the cardiac evaluation patients presented with a mean pulmonary wedge pressure of 19.9 +/- 8.6 mmHg, a cardiac index of 2.5 +/- 0.8 l/min/m2, an end diastolic dimension of the left ventricle of 65.9 +/- 10.1 mm, and end systolic dimension of 51.2 +/- 12.2 mm, with a shortening fraction of 21.8 +/- 9.5%. The pulmonary evaluation showed a restrictive syndrome with a reduction in the mean values of the following parameters: total pulmonary capacity 71 +/- 14.4% of the predicted value (pv), forced vital capacity (FVC) 69.8 +/- 20.5% pv, and forced expiratory volume (FEV1) of 64 +/- 21.8% vp. The index FEV1/FVC was within the normal value of 72.7 +/- 9.7%. These lung function results did not correlate significantly with either the clinical, the hemodynamic or echocardiographic findings. In these group of patients pulmonary congestion led to the development of a restrictive syndrome which failed to correlate in severity with the duration of the disease, the pulmonary wedge pressure and the left ventricular function.
Olfert, S M; Pahwa, P; Dosman, J A
2005-11-01
The negative health effects of exposure to grain dust have previously been examined, but few studies have observed the effects on newly hired employees. Young grain workers are of interest because changes in pulmonary function may occur after a short duration of employment, and because older grain workers may represent a survivor population. The New Grain Workers Study (NGWS), a longitudinal study of 299 newly hired male grain industry workers, was conducted between 1980 and 1985. The objectives were to determine the effects of employment in the grain industry on pulmonary function. Pre-employment physical examinations and pulmonary function tests were conducted on subjects at the Division of Respiratory Medicine, Department of Medicine, Royal University Hospital, University of Saskatchewan. The Grain Dust Medical Surveillance Program (GDMSP) was a Labour Canada program that began in 1978. All subjects were grain workers employed in the grain industry in Saskatchewan. All subjects completed a respiratory symptoms questionnaire and underwent pulmonary function testing. Baseline observations were recorded every three years between 1978 and 1993. Data were available on 2184 grain workers. Generalized estimating equations were used to fit marginal and transitional multivariable regression models to determine the effects of grain dust exposure on pulmonary function. Marginal and transitional models were then compared. Height, exposure weeks, and previous FVC were predictive of FVC in the NGWS, while exposure weeks and previous FEV1 were predictive of FEV1. These models, as well as a transitional regression model built using the GDMSP data, were used to compute predicted mean annual decline inpulmonary function. Non-smoking grain workers in the NGWS had the highest pulmonary function test values, but also had the greatest predicted annual decline in pulmonary function. Ever-smoking grain workers in the GDMSP had the lowest pulmonary function test values. Non-smoking grain workers in the GDMSP had the least predicted annual decline in pulmonary function.
Normal Physiological Values for Conscious Pigs Used in Biomedical Research
1989-05-01
6. Cardiovascular and Pulmonary Functions........... 18 TABLE 7. Bioenergetics..................................... 19 TABLE 8. Renal Function...procedure developed in our laboratory. Plasma concentrations of aldosterone, cortisol, total T3, total T4, free T4, insulin and glucagon were...pulmonary vascular resistance , alveolar ventilation, alveolar ventilation/perfusion ratio, arterial 02 transport, tissue 02 extraction ratio, pulmonary
Spruit, Martijn A; Janssen, Paul P; Willemsen, Sonja C P; Hochstenbag, Monique M H; Wouters, Emiel F M
2006-05-01
Although lung cancer is a highly prevalent type of cancer, the effects of an inpatient multidisciplinary rehabilitation program on pulmonary function and exercise capacity have never been studied in these patients. Pulmonary function, 6-min walking distance and peak exercise capacity of 10 patients with a severely impaired pulmonary function following treatment of lung cancer were assessed in this pilot study before and after an 8-week inpatient multidisciplinary rehabilitation program. At baseline, patients had a restrictive pulmonary function and an apparent exercise intolerance (median 6-min walking distance: 63.6% predicted; median peak cycling load: 58.5% predicted). Despite the lack of change in median pulmonary function [FEV1: -0.01L, p = 0.5469], functional exercise capacity [145 m; 43.2% of the initial values, p=0.0020] and peak exercise capacity [26 W; 34.4% of the initial values, p = 0.0078] improved significantly compared to baseline. Future trials have to corroborate the present findings. Nevertheless, patients with lung cancer have a clear indication to start a comprehensive rehabilitation program following intensive treatment of their disease. In fact, based on the results of the present pilot study it appears that these patients are good candidates for pulmonary rehabilitation programs.
Park, Ji Hye; Mun, Seyeon; Choi, Dong Phil; Lee, Joo Young; Kim, Hyeon Chang
2017-12-11
Accumulating evidence suggests that high-density lipoprotein (HDL) cholesterol is associated with pulmonary function and pulmonary disorders. The aim of this study was to evaluate the association between HDL cholesterol and pulmonary function in healthy adolescents. This cross-sectional study was based on data collected for the JS High School study. The analysis included 644 adolescents (318 male and 326 female) aged 15-16 years old and free from asthma or chronic obstructive pulmonary disease. Fasting blood samples were collected for hematologic and biochemical assessment. Forced vital capacity volume (FVC) and forced expiratory volume in the 1 s (FEV1) were measured using dry-rolling-seal spirometry. The associations between HDL cholesterol and pulmonary function were analyzed using multiple linear regression models. Among male adolescents, an increase of 1.0 mg/dL in HDL cholesterol was associated with 10 mL decrease in FVC (p = 0.013) and FEV1 (p = 0.013) after adjusting for age, height, weight, alcohol drinking, smoking, physical activity, systolic blood pressure, total cholesterol, triglyceride, and monthly household income. Percent predicted values of FVC (p = 0.036) and FEV1 (p = 0.017) were also inversely associated with HDL cholesterol. However, among female adolescents, HDL cholesterol level was not significantly associated with absolute or percent predictive value of FVC and FEV1. Higher HDL cholesterol level may be associated with decreased pulmonary function among healthy male adolescents. The sex differences observed in the association between HDL cholesterol and pulmonary function need further investigation.
Pulmonary functions in patients with subclinical hypothyroidism.
Cakmak, Gulfidan; Saler, Tayyibe; Saglam, Zuhal Aydan; Yenigun, Mustafa; Ataoglu, Esra; Demir, Tuncalp; Temiz, Levent Umit
2011-10-01
To determine whether alterations in pulmonary function takes place in subclinical hypothyroidism by examining the diffusion lung capacity and muscle strength of such patients. This is a descriptive study conducted in 2009 at Haseki Training and Research Hospital, Istanbul, Turkey. Hundred and twenty-six patients with subclinical hypothyroidism and 58 age and sex matched individuals were recruited. Simple spirometry tests were performed, and pulmonary diffusion capacity (DLco) and muscle strength were measured. ScH patients showed a significant reduciton of the following pulmonary function tests (% predicted value) as compared with control subjects: FVC, FEV1, FEV1%, FEF25-75, FEF25-75%, DLco, DLco/VA, Pimax, Pimax% and Pemax%. These data indicate that pulmonary functions are effected in subclinical hypothyrodism. Therefore patients with or who are at high risk of having subclinical hypothyroidism, should be subjected to evaluation of pulmonary functions with simple spirometry.
Ohno, Yoshiharu; Nishio, Mizuho; Koyama, Hisanobu; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Seki, Shinichiro; Obara, Makoto; van Cauteren, Marc; Takahashi, Masaya; Sugimura, Kazuro
2014-04-01
To assess the influence of ultrashort TE (UTE) intervals on pulmonary magnetic resonance imaging (MRI) with UTEs (UTE-MRI) for pulmonary functional loss assessment and clinical stage classification of smokers. A total 60 consecutive smokers (43 men and 17 women; mean age 70 years) with and without COPD underwent thin-section multidetector row computed tomography (MDCT), UTE-MRI, and pulmonary functional measurements. For each smoker, UTE-MRI was performed with three different UTE intervals (UTE-MRI A: 0.5 msec, UTE-MRI B: 1.0 msec, UTE-MRI C: 1.5 msec). By using the GOLD guidelines, the subjects were classified as: "smokers without COPD," "mild COPD," "moderate COPD," and "severe or very severe COPD." Then the mean T2* value from each UTE-MRI and CT-based functional lung volume (FLV) were correlated with pulmonary function test. Finally, Fisher's PLSD test was used to evaluate differences in each index among the four clinical stages. Each index correlated significantly with pulmonary function test results (P < 0.05). CT-based FLV and mean T2* values obtained from UTE-MRI A and B showed significant differences among all groups except between "smokers without COPD" and "mild COPD" groups (P < 0.05). UTE-MRI has a potential for management of smokers and the UTE interval is suggested as an important parameter in this setting. Copyright © 2013 Wiley Periodicals, Inc.
Effect of exercise test on pulmonary function of obese adolescents.
Faria, Alethéa Guimarães; Ribeiro, Maria Angela G O; Marson, Fernando Augusto Lima; Schivinski, Camila Isabel S; Severino, Silvana Dalge; Ribeiro, José Dirceu; Barros Filho, Antônio A
2014-01-01
to investigate the pulmonary response to exercise of non-morbidly obese adolescents, considering the gender. a prospective cross-sectional study was conducted with 92 adolescents (47 obese and 45 eutrophic), divided in four groups according to obesity and gender. Anthropometric parameters, pulmonary function (spirometry and oxygen saturation [SatO2]), heart rate (HR), blood pressure (BP), respiratory rate (RR), and respiratory muscle strength were measured. Pulmonary function parameters were measured before, during, and after the exercise test. BP and HR were higher in obese individuals during the exercise test (p = 0.0001). SatO2 values decreased during exercise in obese adolescents (p = 0.0001). Obese males had higher levels of maximum inspiratory and expiratory pressures (p = 0.0002) when compared to obese and eutrophic females. Obese males showed lower values of maximum voluntary ventilation, forced vital capacity, and forced expiratory volume in the first second when compared to eutrophic males, before and after exercise (p = 0.0005). Obese females had greater inspiratory capacity compared to eutrophic females (p = 0.0001). Expiratory reserve volume was lower in obese subjects when compared to controls (p ≤ 0,05). obese adolescents presented changes in pulmonary function at rest and these changes remained present during exercise. The spirometric and cardiorespiratory values were different in the four study groups. The present data demonstrated that, in spite of differences in lung growth, the model of fat distribution alters pulmonary function differently in obese female and male adolescents. Copyright © 2013 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
Cukic, Vesna
2012-01-01
Introduction: Nowadays an increasing number of lung resections are being done because of the rising prevalence of lung cancer that occurs mainly in patients with limited lung function, what is caused by common etiologic factor - smoking cigarettes. Loss of lung tissue in such patients can worsen much the postoperative pulmonary function. So it is necessary to asses the postoperative pulmonary function especially after maximal resection, i.e. pneumonectomy. Objective: To check over the accuracy of preoperative prognosis of postoperative lung function after pneumonectomy using spirometry and lung perfusion scinigraphy. Material and methods: The study was done on 17 patients operated at the Clinic for thoracic surgery, who were treated previously at the Clinic for Pulmonary Diseases “Podhrastovi” in the period from 01. 12. 2008. to 01. 06. 2011. Postoperative pulmonary function expressed as ppoFEV1 (predicted postoperative forced expiratory volume in one second) was prognosticated preoperatively using spirometry, i.e.. simple calculation according to the number of the pulmonary segments to be removed and perfusion lung scintigraphy. Results: There is no significant deviation of postoperative achieved values of FEV1 from predicted ones obtained by both methods, and there is no significant differences between predicted values (ppoFEV1) obtained by spirometry and perfusion scintigraphy. Conclusion: It is necessary to asses the postoperative pulmonary function before lung resection to avoid postoperative respiratory failure and other cardiopulmonary complications. It is absolutely necessary for pneumonectomy, i.e.. maximal pulmonary resection. It can be done with great possibility using spirometry or perfusion lung scintigraphy. PMID:23378687
Influence of stapling the intersegmental planes on lung volume and function after segmentectomy.
Tao, Hiroyuki; Tanaka, Toshiki; Hayashi, Tatsuro; Yoshida, Kumiko; Furukawa, Masashi; Yoshiyama, Koichi; Okabe, Kazunori
2016-10-01
Dividing the intersegmental planes with a stapler during pulmonary segmentectomy leads to volume loss in the remnant segment. The aim of this study was to assess the influence of segment division methods on preserved lung volume and pulmonary function after segmentectomy. Using image analysis software on computed tomography (CT) images of 41 patients, the ratio of remnant segment and ipsilateral lung volume to their preoperative values (R-seg and R-ips) was calculated. The ratio of postoperative actual forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC) per those predicted values based on three-dimensional volumetry (R-FEV1 and R-FVC) was also calculated. Differences in actual/predicted ratios of lung volume and pulmonary function for each of the division methods were analysed. We also investigated the correlations of the actual/predicted ratio of remnant lung volume with that of postoperative pulmonary function. The intersegmental planes were divided by either electrocautery or with a stapler in 22 patients and with a stapler alone in 19 patients. Mean values of R-seg and R-ips were 82.7 (37.9-140.2) and 104.9 (77.5-129.2)%, respectively. The mean values of R-FEV1 and R-FVC were 103.9 (83.7-135.1) and 103.4 (82.2-125.1)%, respectively. There were no correlations between the actual/predicted ratio of remnant lung volume and pulmonary function based on the division method. Both R-FEV1 and R-FVC were correlated not with R-seg, but with R-ips. Stapling does not lead to less preserved volume or function than electrocautery in the division of the intersegmental planes. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
NASA Astrophysics Data System (ADS)
Tanaka, Rie; Matsuda, Hiroaki; Sanada, Shigeru
2017-03-01
The density of lung tissue changes as demonstrated on imagery is dependent on the relative increases and decreases in the volume of air and lung vessels per unit volume of lung. Therefore, a time-series analysis of lung texture can be used to evaluate relative pulmonary function. This study was performed to assess a time-series analysis of lung texture on dynamic chest radiographs during respiration, and to demonstrate its usefulness in the diagnosis of pulmonary impairments. Sequential chest radiographs of 30 patients were obtained using a dynamic flat-panel detector (FPD; 100 kV, 0.2 mAs/pulse, 15 frames/s, SID = 2.0 m; Prototype, Konica Minolta). Imaging was performed during respiration, and 210 images were obtained over 14 seconds. Commercial bone suppression image-processing software (Clear Read Bone Suppression; Riverain Technologies, Miamisburg, Ohio, USA) was applied to the sequential chest radiographs to create corresponding bone suppression images. Average pixel values, standard deviation (SD), kurtosis, and skewness were calculated based on a density histogram analysis in lung regions. Regions of interest (ROIs) were manually located in the lungs, and the same ROIs were traced by the template matching technique during respiration. Average pixel value effectively differentiated regions with ventilatory defects and normal lung tissue. The average pixel values in normal areas changed dynamically in synchronization with the respiratory phase, whereas those in regions of ventilatory defects indicated reduced variations in pixel value. There were no significant differences between ventilatory defects and normal lung tissue in the other parameters. We confirmed that time-series analysis of lung texture was useful for the evaluation of pulmonary function in dynamic chest radiography during respiration. Pulmonary impairments were detected as reduced changes in pixel value. This technique is a simple, cost-effective diagnostic tool for the evaluation of regional pulmonary function.
Validation of the plain chest radiograph for epidemiologic studies of airflow obstruction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Musk, A.W.
The chest radiographs of 125 industrial workers from rural New South Wales were examined for overinflated lungs, with and without attenuated midzonal vessels. Although the mean values of a comprehensive range of pulmonary function tests in the whole group were within normal limits, the nine subjects whose radiographs showed overinflated lungs and attenuated vessels had significantly impaired pulmonary function in comparison with 85 subjects with normal radiographs. The mean values for these nine subjects, expressed as a percentage of the mean value for subjects with normal radiographs, were: forced expiratory volume in 1 second, 75%; total lung capacity, 107%; residualmore » volume, 143%; transpulmonary pressure at maximum inspiration, 60%; static deflation compliance, 158%; lung volume at transpulmonary pressure 10 cm H/sub 2/O, 132%; transfer factor, 79%; and transfer factor/alveolar volume, 77%. Similar results were obtained by a second observer. Those subjects with overinflation but no vascular attenuation had significantly larger mean values for vital capacity and alveolar volume but no significant difference in total lung capacity or other tests of the mechanical properties of the lungs. Agreement on the presence of a positive sign between the two observers expressed as a percentage of those considered positive by either was 81% for overinflation and 62% for attenuated midzonal vessels. The results indicate that in groups of subjects with normal-average values of pulmonary function, the plain chest radiograph may provide information concerning pulmonary structure that is reflected in tests of function.« less
Pulmonary function and health-related quality of life 1-year follow up after cardiac surgery.
Westerdahl, Elisabeth; Jonsson, Marcus; Emtner, Margareta
2016-07-08
Pulmonary function is severely reduced in the early period after cardiac surgery, and impairments have been described up to 4-6 months after surgery. Evaluation of pulmonary function in a longer perspective is lacking. In this prospective study pulmonary function and health-related quality of life were investigated 1 year after cardiac surgery. Pulmonary function measurements, health-related quality of life (SF-36), dyspnoea, subjective breathing and coughing ability and pain were evaluated before and 1 year after surgery in 150 patients undergoing coronary artery bypass grafting, valve surgery or combined surgery. One year after surgery the forced vital capacity and forced expiratory volume in 1 s were significantly decreased (by 4-5 %) compared to preoperative values (p < 0.05). Saturation of peripheral oxygen was unchanged 1 year postoperatively compared to baseline. A significantly improved health-related quality of life was found 1 year after surgery, with improvements in all eight aspects of SF-36 (p < 0.001). Sternotomy-related pain was low 1 year postoperatively at rest (median 0 [min-max; 0-7]), while taking a deep breath (0 [0-4]) and while coughing (0 [0-8]). A more pronounced decrease in pulmonary function was associated with dyspnoea limitations and impaired subjective breathing and coughing ability. One year after cardiac surgery static and dynamic lung function measurements were slightly decreased, while health-related quality of life was improved in comparison to preoperative values. Measured levels of pain were low and saturation of peripheral oxygen was same as preoperatively.
Pulmonary adverse effects of welding fume in automobile assembly welders.
Sharifian, Seyed Akbar; Loukzadeh, Ziba; Shojaoddiny-Ardekani, Ahmad; Aminian, Omid
2011-01-01
Welding is one of the key components of numerous manufacturing industries, which has potential physical and chemical health hazards. Many components of welding fumes can potentially affect the lung function. This study investigates the effects of welding fumes on lung function and respiratory symptoms among welders of an automobile manufacturing plant in Iran. This historical cohort study assesses 43 male welders and 129 office workers by a questionnaire to record demographic data, smoking habits, work history and respiratory symptoms as well as lung function status by spirometry. The average pulmonary function values of welders were lower relative to controls with dose-effect relationship between work duration and pulmonary function impairment. The prevalence of chronic bronchitis was higher in welders than controls. Our findings suggest that welders are at risk for pulmonary disease.
Pulmonary function studies in young healthy Malaysians of Kelantan, Malaysia.
Bandyopadhyay, Amit
2011-11-01
Pulmonary function tests have been evolved as clinical tools in diagnosis, management and follow up of respiratory diseases as it provides objective information about the status of an individual's respiratory system. The present study was aimed to evaluate pulmonary function among the male and female young Kelantanese Malaysians of Kota Bharu, Malaysia, and to compare the data with other populations. A total of 128 (64 males, 64 females) non-smoking healthy young subjects were randomly sampled for the study from the Kelantanese students' population of the University Sains Malaysia, Kota Bharu Campus, Kelantan, Malaysia. The study population (20-25 yr age group) had similar socio-economic background. Each subject filled up the ATS (1978) questionnaire to record their personal demographic data, health status and consent to participate in the study. Subjects with any history of pulmonary diseases were excluded from the study. The pulmonary function measurements exhibited significantly higher values among males than the females. FEV 1% did not show any significant inter-group variation probably because the parameter expresses FEV 1 as a percentage of FVC. FVC and FEV 1 exhibited significant correlations with body height and body mass among males whereas in the females exhibited significant correlation with body mass, body weight and also with age. FEV 1% exhibited significant correlation with body height and body mass among males and with body height in females. FEF 25-75% did not show any significant correlation except with body height among females. However, PEFR exhibited significant positive correlation with all the physical parameters except with age among the females. On the basis of the existence of significant correlation between different physical parameters and pulmonary function variables, simple and multiple regression norms have been computed. From the present investigation it can be concluded that Kelantanese Malaysian youths have normal range of pulmonary function in both the sexes and the computed regression norms may be used to predict the pulmonary function values in the studied population.
Pulmonary function studies in young healthy Malaysians of Kelantan, Malaysia
Bandyopadhyay, Amit
2011-01-01
Background & objectives: Pulmonary function tests have been evolved as clinical tools in diagnosis, management and follow up of respiratory diseases as it provides objective information about the status of an individual's respiratory system. The present study was aimed to evaluate pulmonary function among the male and female young Kelantanese Malaysians of Kota Bharu, Malaysia, and to compare the data with other populations. Methods: A total of 128 (64 males, 64 females) non-smoking healthy young subjects were randomly sampled for the study from the Kelantanese students’ population of the University Sains Malaysia, Kota Bharu Campus, Kelantan, Malaysia. The study population (20-25 yr age group) had similar socio-economic background. Each subject filled up the ATS (1978) questionnaire to record their personal demographic data, health status and consent to participate in the study. Subjects with any history of pulmonary diseases were excluded from the study. Results: The pulmonary function measurements exhibited significantly higher values among males than the females. FEV1% did not show any significant inter-group variation probably because the parameter expresses FEV1 as a percentage of FVC. FVC and FEV1 exhibited significant correlations with body height and body mass among males whereas in the females exhibited significant correlation with body mass, body weight and also with age. FEV1% exhibited significant correlation with body height and body mass among males and with body height in females. FEF25-75% did not show any significant correlation except with body height among females. However, PEFR exhibited significant positive correlation with all the physical parameters except with age among the females. On the basis of the existence of significant correlation between different physical parameters and pulmonary function variables, simple and multiple regression norms have been computed. Interpretation & conclusions: From the present investigation it can be concluded that Kelantanese Malaysian youths have normal range of pulmonary function in both the sexes and the computed regression norms may be used to predict the pulmonary function values in the studied population. PMID:22199104
Effect of drug-induced hyperuricaemia on renal function in Nigerians with pulmonary tuberculosis.
Adebisi, S A; Oluboyo, P O; Okesina, A B
2000-01-01
Some anti-tuberculosis chemotherapeutic agents have been established as causing hyperuricaemia. Hyperuricaemia in turn causes renal damage. This study therefore aims at establishing the effect of anti-tuberculosis drugs-induced hyperuricaemia on renal function of the patients. Fifty patients with newly diagnosed pulmonary tuberculosis with mean age of 36.8 years (SD 13.69) consisting of 14 females and 17 males were longitudinally studied each for 6 months to determine the effect of drug-induced hyperuricaemia on their renal function. The Biochemical indices determined included serum urate level, serum creatinine level, and creatinine clearance of newly diagnosed patient with tuberculosis, before and during treatment with anti-tuberculosis therapy. Serum urate level revealed that 16 (51.6%) and 15 (48.4%) of the patients were hyperuricaemic at the end of the first and second months of anti-tuberculosis therapy. There was no significant difference in the mean serum creatinine level of the control group 96 micromol/L when compared with both the pre-treat value 89 micromol/L (P > 0.25) as well as the value at the end of the sixth month of treatment 91 micromol/L (P > 0.40). However, there was a statistically significant difference in the mean creatinine clearance of the control group 102 ml/min/1.73 m2 when compared with the patient's mean pre-treatment value (89 ml/min/1.73 m2) P < 0.05. Also the mean creatinine clearance increased to (103 ml/min/1.73 m2) by the end of the 6th month of treatment, a value that is statistically significant when compared with the pretreatment value of (89 ml/min/1.73 m2) P < 0.05. We submit as follows: that pulmonary tuberculosis as a disease with significant impairment of renal function; despite the associated drug-induced hyperuricaemia recorded during the treatment, renal function steadily improved with the treatment of pulmonary tuberculosis to the extent that comparable values with control was obtained at the end of treatment. We conclude therefore that drug-induced hyperuricaemia associated with treatment of pulmonary tuberculosis has no detectable negative effect on renal function of the patient.
[Pulmonary function in patients with focal pulmonary tuberculosis].
Nefedov, V B; Popova, L A; Shergina, E A
2008-01-01
Vital capacity (VC), forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), FEV1/VC%, PEF, MEF25, MEF50, MEF75, TLC, TGV, pulmonary residual volume (PRV), Raw, Rin, Rcx, DLCO-SB, DLCO-SS/VA, PaO2, and PaCO2 were determined in 40 patients with focal pulmonary tuberculosis. Changes were found in lung volumes and capacities in 75%, impaired bronchial patency and pulmonary gas exchange dysfunction were in 57.5 and 25%, respectively. The lung volume and capacity changes appeared mainly as increased TGV and PRV; impaired bronchial patency presented as decreased MEF50, MEF75, and FEV1/VC%; pulmonary gas exchange dysfunction manifested itself as reduced DLCO-SB, PaO2, and PaCO2. The magnitude of the observed functional changes was generally slight. TGV and PRL increased up to 148-187 and 142-223% of the normal values, respectively; MEF50, MEF75, FEV1/VC%, and DLCO decreased to 59-24, 58-26, 78-57, and 78-67% of the normal values and PaO2 and PaCO2 did to 79-69 and 34-30 cm Hg.
Castellví, Ivan; Simeón-Aznar, Carmen Pilar; Sarmiento, Mónica; Fortuna, Ana; Mayos, Mercedes; Geli, Carme; Diaz-Torné, César; Moya, Patricia; De Llobet, Josep Maria; Casademont, Jordi
2015-02-01
To determine whether there is an association between different capillaroscopic findings and pulmonary function tests in systemic sclerosis (SSc). We did a retrospective observational study in a cohort of patients with SSc and early SSc. Patients with at least 1 nailfold videocapillaroscopy (NVC) magnified 120× were included. Pathological findings were giant capillaries, angiogenesis, and density loss. Findings were compared with lung function values: percent expected value of forced vital capacity (FVC), DLCO, and FVC/DLCO ratio. Other variables collected were sex and SSc type, and the presence of digital ulcers (DU), interstitial lung disease (ILD), scleroderma renal crisis, and/or pulmonary hypertension (PH). Of 136 patients with SSc, 85 had undergone an NVC. The frequency of ILD, DU, and PH was 24.1%, 28.7%, and 17.2%, respectively. Data analysis showed that patients with density loss had worse FVC% (86.91 ± 19.42 vs 101.13 ± 16.06, p < 0.01) and DLCO% (71.43 ± 21.19 vs 85.9 ± 19.81, p < 0.01) compared to those without. Patients with loss of density present worse FVC and DLCO values. Prospective studies are warranted to determine whether NVC is useful for studying pulmonary function in SSc.
[Functional respiratory evolution in two patients with emphysema and pulmonary fibrosis].
Arce, Santiago C; Molinari, Luciana; De Vito, Eduardo L
2009-01-01
Combined pulmonary fibrosis and emphysema (CPFE) is a frequently under-diagnosed condition. Isolated pulmonary function tests (PFT) can give rise to misinterpretations. We have found no reports on these patients' spirometric progression. We describe two cases of CPFE, showing long-term functional evolution to have a more accurate understanding of current spirometric values. The most relevant findings are: 1) spirometry with discrete functional alterations in the presence of a marked dyspnea and the need, in one patient, for chronic oxygen therapy; and 2) functional evolution reflecting "pseudonormalisation" of the initial obstructive spirometric pattern, possibly as a result of fibrosis development. A mild obstructive defect in a patient with chronic airflow limitation and marked impairment of his/her clinical status and functional class should alert on the possibility of associated pulmonary fibrosis. A computed tomography (CT) and previous PFTs will allow a better understanding of this condition.
Pulmonary function and fuel use: a population survey.
Saha, Asim; Rao, N Mohan; Kulkarni, P K; Majumdar, P K; Saiyed, H N
2005-10-31
In the backdrop of conflicting reports (some studies reported adverse outcomes of biomass fuel use whereas few studies reported absence of any association between adverse health effect and fuel use, may be due to presence of large number of confounding variables) on the respiratory health effects of biomass fuel use, this cross sectional survey was undertaken to understand the role of fuel use on pulmonary function. This study was conducted in a village of western India involving 369 randomly selected adult subjects (165 male and 204 female). All the subjects were interviewed and were subjected to pulmonary function test. Analysis of covariance was performed to compare the levels of different pulmonary function test parameters in relation to different fuel use taking care of the role of possible confounding factors. This study showed that biomass fuel use (especially wood) is an important factor for deterioration of pulmonary function (particularly in female). FEV1 (p < .05), FEV1% (p < .01), PEFR (p < .05) and FEF(25-75) (p < .01) values were significantly lower in biomass fuel using females than nonusers. Comparison of only biomass fuel use vs. only LPG (Liquefied Petroleum Gas) use and only wood vs. only LPG use has showed that LPG is a safer fuel so far as deterioration of pulmonary function is concerned. This study observes some deterioration of pulmonary function in the male subjects also, who came from biomass fuel using families. This study concluded that traditional biomass fuels like wood have adverse effects on pulmonary function.
Supomo, Supomo; Darmawan, Handy; Arjana, Adika Zhulhi
2018-05-22
The presence of altered pulmonary hemodynamics in adult patients with atrial septal defect (ASD) is common. However, there are no observational studies which evaluate the impact of altered pulmonary hemodynamics on the 6-min walk test (6MWT) result. This study aimed to investigate the role of pulmonary hemodynamics in determining 6MWT result of patients with ASD. Forty-six consecutive adult patients with ASD were included in this study. Right heart catheterization was performed to obtain the pulmonary hemodynamics profile. Meanwhile, 6MWT was presented as high or low with cut-off point 350 m. Receiver operating characteristic (ROC) was used for analytical methods. Abnormal functional capacity was indicated by ROC result of mPAP cut-off value of > 24 mmHg (p = 0.0243; AUC = 0.681). The value of PVR > 3.42 woods unit (WU) showed high specificity in determining abnormal functional capacity (p = 0.0069; AUC = 0.713). Flow ratio with cut-off point ≤4.89 had the highest sensitivity (100%) (p = 0.8300; AUC = 0.520). Pulmonary hemodynamics can serve as an indicator of 6MWT result in adult ASD patients with values of mPAP> 24 mmHg and PVR > 3.42 WU.
Effects of air pollution on children’s pulmonary health
NASA Astrophysics Data System (ADS)
Tabaku, Afrim; Bejtja, Gazmend; Bala, Silvana; Toci, Ervin; Resuli, Jerina
2011-12-01
IntroductionMany reports regarding the effects of air pollution on children's respiratory health have appeared in the scientific literature. Some investigators found increases in persistent cough and phlegm, bronchitis, and early respiratory infections in communities with poor air quality. The purpose of this survey was to compare the pulmonary function of children living in urban area of Tirana city with children living in suburban area of the city. Material and methodsThis survey is carried out during 2004-2005 period on 238 children living in urban area and in 72 children living in suburban area, measuring dynamic pulmonary function. A questionnaire was used to collect data on sex, current respiratory symptoms, allergy diagnosed by the physician, parent education and smoking habit of parents, presence of animals, synthetic carpets and moulds in their houses. The selection of schools, and children included in this survey was done by randomized method. Also, we have measured and classic air pollutants. ResultsComparing the results of values of pulmonary function of two groups of children, we have shown that differences were significant ( p 0.001), whereas comparing symptoms were for cough ( p 0.011) and for phlegm ( p 0.032). The level of particulate matter (PM10) and total suspended matter (TSP) were over the recommended limit values, whereas the levels of other pollutants have resulted within recommended levels of World Health Organization (WHO) ConclusionsThe results of this survey suggest that air pollution is associated with respiratory health of children causing a slight decrease in values of pulmonary function in children of urban area compared with those of suburban area.
Ateş, Oğuz; Karakuş, Osman Z; Hakgüder, Gülce; Olguner, Mustafa; Akgür, Feza M
2013-09-01
The treatment of pectus carinatum (PC) deformity has been considered to be operative. Some authors have shown that postoperative pulmonary function is worsened. They have suggested that compromised chest wall expansion secondary to surgery leads to compromised pulmonary function. Several authors have advocated an orthotic brace for the treatment of PC. Pulmonary functions after orthotic brace treatment have not been investigated. Between April 2006 and October 2012, 61 patients presented with PC. Orthotic braces allowing gradual compression were prepared according to the anthropometric measurements of individual patients. The brace belt was tightened gradually. The brace was worn 6 h a day during the first week and the bracing time was prolonged for an additional hour per week till 16 h per day has been reached. Pre- and post-treatment echocardiography, pulmonary function tests and thorax computed tomography (CT) were obtained. The pectus severity index (Haller index) and the angle of sternal rotation were measured using CT. Satisfaction from bracing was evaluated by parents or patients at the end of the treatment. While the mean pretreatment Haller index was 1.96 ± 0.24, the mean post-treatment index was 2.26 ± 0.32. The angle of rotation was improved by 47.5%. Forced vital capacity and forced expiratory volume in 1 second were correlated with the predicted values for age. There was no statistically significant difference between pre- and post-treatment values. No skin breakdown or bruising was encountered. The overall average satisfaction score was 3.92 ± 0.27. We conclude that pulmonary function tests are not affected after brace treatment and gradual progression of bracing increases the patient's compliance.
Advanced Techniques in Pulmonary Function Test Analysis Interpretation and Diagnosis
Gildea, T.J.; Bell, C. William
1980-01-01
The Pulmonary Functions Analysis and Diagnostic System is an advanced clinical processing system developed for use at the Pulmonary Division, Department of Medicine at the University of Nebraska Medical Center. The system generates comparative results and diagnostic impressions for a variety of routine and specialized pulmonary functions test data. Routine evaluation deals with static lung volumes, breathing mechanics, diffusing capacity, and blood gases while specialized tests include lung compliance studies, small airways dysfunction studies and dead space to tidal volume ratios. Output includes tabular results of normal vs. observed values, clinical impressions and commentary and, where indicated, a diagnostic impression. A number of pulmonary physiological and state variables are entered or sampled (A to D) with periodic status reports generated for the test supervisor. Among the various physiological variables sampled are respiratory frequency, minute ventilation, oxygen consumption, carbon dioxide production, and arterial oxygen saturation.
Tumor necrosis factor alpha and pulmonary function in Saskatchewan grain handlers.
McDuffie, Helen H; Nakagawa, Kazuko; Pahwa, Punam; Shindo, Junichi; Hashimoto, Mirai; Nakada, Naoyuki; Ghosh, Sunita; Kirychuk, Shelley P; Hucl, Pierre
2006-05-01
The objective of this study was to estimate the contribution of lifestyle (cigarettes) and tumor necrosis factor (TNF) alpha polymorphisms at position 308 of the tumor necrosis factor alpha gene promotor (TNF-308*1/*2) to pulmonary function among grain handlers. Employed male grain handlers (157) provided occupational and respiratory symptom information, pulmonary function measurements, and DNA for genotyping. The genotypes of 101 were TNF-308*1/*1, 47 were *1/*2, and nine were *2/*2. Current smokers whose genotype was *2/*2 or *1/*2 had lower values compared with other combinations of genotype and smoking status. Among *1/*1 homozygotes, current smokers had better percent of predicted forced expiratory volume in 1 second (P = 0.04) mean values than nonsmokers and better percent of predicted forced vital capacity than exsmokers (P = 0.017) or nonsmokers (P = 0.008). These results indicate the complexity of determining which workers will develop acute and chronic adverse pulmonary conditions in response to exposure to grain dust and the toxins in cigarette smoke interacting with their genotype.
The impact of bariatric surgery on pulmonary function: a meta-analysis.
Alsumali, Adnan; Al-Hawag, Ali; Bairdain, Sigrid; Eguale, Tewodros
2018-02-01
Morbid obesity may affect several body systems and cause ill effects to the cardiovascular, hepatobiliary, endocrine, and mental health systems. However, the impact on the pulmonary system and pulmonary function has been debated in the literature. A systematic review and meta-analysis for studies that have evaluated the impact of bariatric surgery on pulmonary function were pooled for this analysis. PubMed, Cochrane, and Embase databases were evaluated through September 31, 2016. They were used as the primary search engine for studies evaluating the impact pre- and post-bariatric surgery on pulmonary function. Pooled effect estimates were calculated using random-effects model. Twenty-three studies with 1013 participants were included in the final meta-analysis. Only 8 studies had intervention and control groups with different time points, but 15 studies had matched groups with different time points. Overall, pulmonary function score was significantly improved after bariatric surgery, with a pooled standardized mean difference of .59 (95% confidence interval: .46-.73). Heterogeneity test was performed by using Cochran's Q test (I 2 = 46%; P heterogeneity = .10). Subgroup analysis and univariate meta-regression based on study quality, age, presurgery body mass index, postsurgery body mass index, study design, female patients only, study continent, asthmatic patients in the study, and the type of bariatric surgery confirmed no statistically significant difference among these groups (P value>.05 for all). A multivariate meta-regression model, which adjusted simultaneously for these same covariates, did not change the results (P value > .05 overall). Assessment of publication bias was done visually and by Begg's rank correlation test and indicated the absence of publication bias (asymmetric shape was observed and P = .34). This meta-analysis shows that bariatric surgery significantly improved overall pulmonary functions score for morbid obesity. Copyright © 2018 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.
Pulmonary function and fuel use: A population survey
Saha, Asim; Mohan Rao, N; Kulkarni, PK; Majumdar, PK; Saiyed, HN
2005-01-01
Background In the backdrop of conflicting reports (some studies reported adverse outcomes of biomass fuel use whereas few studies reported absence of any association between adverse health effect and fuel use, may be due to presence of large number of confounding variables) on the respiratory health effects of biomass fuel use, this cross sectional survey was undertaken to understand the role of fuel use on pulmonary function. Method This study was conducted in a village of western India involving 369 randomly selected adult subjects (165 male and 204 female). All the subjects were interviewed and were subjected to pulmonary function test. Analysis of covariance was performed to compare the levels of different pulmonary function test parameters in relation to different fuel use taking care of the role of possible confounding factors. Results This study showed that biomass fuel use (especially wood) is an important factor for deterioration of pulmonary function (particularly in female). FEV1 (p < .05), FEV1 % (p < .01), PEFR (p < .05) and FEF25–75 (p < .01) values were significantly lower in biomass fuel using females than nonusers. Comparison of only biomass fuel use vs. only LPG (Liquefied Petroleum Gas) use and only wood vs. only LPG use has showed that LPG is a safer fuel so far as deterioration of pulmonary function is concerned. This study observes some deterioration of pulmonary function in the male subjects also, who came from biomass fuel using families. Conclusion This study concluded that traditional biomass fuels like wood have adverse effects on pulmonary function. PMID:16255784
Noll, Donald R; Johnson, Jane C; Baer, Robert W; Snider, Eric J
2009-01-01
Background The use of manipulation has long been advocated in the treatment of chronic obstructive pulmonary disease (COPD), but few randomized controlled clinical trials have measured the effect of manipulation on pulmonary function. In addition, the effects of individual manipulative techniques on the pulmonary system are poorly understood. Therefore, the purpose of this study was to determine the immediate effects of four osteopathic techniques on pulmonary function measures in persons with COPD relative to a minimal-touch control protocol. Methods Persons with COPD aged 50 and over were recruited for the study. Subjects received five, single-technique treatment sessions: minimal-touch control, thoracic lymphatic pump (TLP) with activation, TLP without activation, rib raising, and myofascial release. There was a 4-week washout period between sessions. Protocols were given in random order until all five techniques had been administered. Pulmonary function measures were obtained at baseline and 30-minutes posttreatment. For the actual pulmonary function measures and percent predicted values, Wilcoxon signed rank tests were used to test within-technique changes from baseline. For the percent change from baseline, Friedman tests were used to test for between-technique differences. Results Twenty-five subjects were enrolled in the study. All four tested osteopathic techniques were associated with adverse posttreatment changes in pulmonary function measures; however, different techniques changed different measures. TLP with activation increased posttreatment residual volume compared to baseline, while TLP without activation did not. Side effects were mild, mostly posttreatment chest wall soreness. Surprisingly, the majority of subjects believed they could breathe better after receiving osteopathic manipulation. Conclusion In persons with COPD, TLP with activation, TLP without activation, rib raising, and myofascial release mildly worsened pulmonary function measures immediately posttreatment relative to baseline measurements. The activation component of the TLP technique appears to increase posttreatment residual volume. Despite adverse changes in pulmonary function measures, persons with COPD subjectively reported they benefited from osteopathic manipulation. PMID:19814829
Noll, Donald R; Johnson, Jane C; Baer, Robert W; Snider, Eric J
2009-10-08
The use of manipulation has long been advocated in the treatment of chronic obstructive pulmonary disease (COPD), but few randomized controlled clinical trials have measured the effect of manipulation on pulmonary function. In addition, the effects of individual manipulative techniques on the pulmonary system are poorly understood. Therefore, the purpose of this study was to determine the immediate effects of four osteopathic techniques on pulmonary function measures in persons with COPD relative to a minimal-touch control protocol. Persons with COPD aged 50 and over were recruited for the study. Subjects received five, single-technique treatment sessions: minimal-touch control, thoracic lymphatic pump (TLP) with activation, TLP without activation, rib raising, and myofascial release. There was a 4-week washout period between sessions. Protocols were given in random order until all five techniques had been administered. Pulmonary function measures were obtained at baseline and 30-minutes posttreatment. For the actual pulmonary function measures and percent predicted values, Wilcoxon signed rank tests were used to test within-technique changes from baseline. For the percent change from baseline, Friedman tests were used to test for between-technique differences. Twenty-five subjects were enrolled in the study. All four tested osteopathic techniques were associated with adverse posttreatment changes in pulmonary function measures; however, different techniques changed different measures. TLP with activation increased posttreatment residual volume compared to baseline, while TLP without activation did not. Side effects were mild, mostly posttreatment chest wall soreness. Surprisingly, the majority of subjects believed they could breathe better after receiving osteopathic manipulation. In persons with COPD, TLP with activation, TLP without activation, rib raising, and myofascial release mildly worsened pulmonary function measures immediately posttreatment relative to baseline measurements. The activation component of the TLP technique appears to increase posttreatment residual volume. Despite adverse changes in pulmonary function measures, persons with COPD subjectively reported they benefited from osteopathic manipulation.
Watanabe, Masanari; Noma, Hisashi; Kurai, Jun; Sano, Hiroyuki; Ueda, Yasuto; Mikami, Masaaki; Yamamoto, Hiroyuki; Tokuyasu, Hirokazu; Kato, Kazuhiro; Konishi, Tatsuya; Tatsukawa, Toshiyuki; Shimizu, Eiji; Kitano, Hiroya
2016-01-01
Background Asian dust (AD) exposure exacerbates pulmonary dysfunction in patients with asthma. Asthma–chronic obstructive pulmonary disease overlap syndrome (ACOS), characterized by coexisting symptoms of asthma and chronic obstructive pulmonary disease, is considered a separate disease entity. Previously, we investigated the effects of AD on pulmonary function in adult patients with asthma. Here, we present the findings of our further research on the differences in the effects of AD exposure on pulmonary function between patients with asthma alone and those with ACOS. Methods Between March and May 2012, we conducted a panel study wherein we monitored daily peak expiratory flow (PEF) values in 231 adult patients with asthma. These patients were divided into 190 patients with asthma alone and 41 patients with ACOS in this study. Daily AD particle levels were measured using light detection and ranging systems. Two heavy AD days (April 23 and 24) were determined according to the Japan Meteorological Agency definition. A linear mixed model was used to estimate the association between PEF and AD exposure. Results Increments in the interquartile range of AD particles (0.018 km−1) led to PEF changes of −0.50 L/min (95% confidence interval, −0.98 to −0.02) in patients with asthma alone and −0.11 L/min (−0.11 to 0.85) in patients with ACOS. The PEF changes after exposure to heavy AD were −2.21 L/min (−4.28 to −0.15) in patients with asthma alone and −2.76 L/min (−6.86 to 1.35) in patients with ACOS. In patients with asthma alone, the highest decrease in PEF values was observed on the heavy AD day, with a subsequent gradual increase over time. Conclusion Our results suggest that the effects of AD exposure on pulmonary function differ between patients with asthma alone and ACOS, with the former exhibiting a greater likelihood of decreased pulmonary function after AD exposure. PMID:26869784
Ohno, Yoshiharu; Koyama, Hisanobu; Yoshikawa, Takeshi; Matsumoto, Keiko; Takahashi, Masaya; Van Cauteren, Marc; Sugimura, Kazuro
2011-08-01
The purpose of this study was to determine the usefulness of MRI with ultrashort TEs on a 3-T system and of thin-section MDCT for pulmonary function assessment and clinical stage classification of chronic obstructive pulmonary disease (COPD) in smokers. Forty smokers (24 men and 16 women; mean age ± SD, 68.0 ± 9.3 years) underwent MRI with ultrashort TEs and thin-section MDCT. Pulmonary function testing was also performed to determine the following: the ratio of forced expiratory volume in 1 second to forced vital capacity (percentage predicted) (FEV(1/)FVC%), percentage predicted forced expiratory volume in 1 second (%FEV(1)), and percentage predicted diffusing capacity of lung for carbon monoxide corrected for alveolar volume (%DLCO/V(A)). All subjects were classified into one of four groups as follows: smokers without COPD, with mild COPD, with moderate COPD, and with severe or very severe COPD. T2(*) maps were expressed using proprietary software. Regional T2(*) values were determined by region of interest measurements and were averaged to determine a mean T2(*) value for each subject. CT-based functional lung volume and the ratio of the wall area to the total airway area were also determined. All indexes were statistically correlated with pulmonary function parameters. Then, all indexes were compared among all groups by means of Tukey's honest significance test. All indexes had significant correlation with FEV(1)/FVC%, %FEV(1), and % DLCO/V(A) (p < 0.05). All indexes except WA% of smokers without COPD and smokers with mild COPD differed significantly from those of smokers with moderate COPD and smokers with severe or very severe COPD (p < 0.05). Moreover, the mean T2(*) value of the moderate COPD group was significantly different from that of the severe or very severe COPD group (p < 0.05). MRI with ultrashort TEs is potentially as useful as quantitatively assessed MDCT for pulmonary function loss assessment and clinical stage classification of COPD in smokers.
Reduction of Pulmonary Function After Surgical Lung Resections of Different Volume
Cukic, Vesna
2014-01-01
Introduction: In recent years an increasing number of lung resections are being done because of the rising prevalence of lung cancer that occurs mainly in patients with limited lung function, what is caused with common etiologic factor - smoking cigarettes. Objective: To determine how big the loss of lung function is after surgical resection of lung of different range. Methods: The study was done on 58 patients operated at the Clinic for thoracic surgery KCU Sarajevo, previously treated at the Clinic for pulmonary diseases “Podhrastovi” in the period from 01.06.2012. to 01.06.2014. The following resections were done: pulmectomy (left, right), lobectomy (upper, lower: left and right). The values of postoperative pulmonary function were compared with preoperative ones. As a parameter of lung function we used FEV1 (forced expiratory volume in one second), and changes in FEV1 are expressed in liters and in percentage of the recorded preoperative and normal values of FEV1. Measurements of lung function were performed seven days before and 2 months after surgery. Results: Postoperative FEV1 was decreased compared to preoperative values. After pulmectomy the maximum reduction of FEV1 was 44%, and after lobectomy it was 22% of the preoperative values. Conclusion: Patients with airway obstruction are limited in their daily life before the surgery, and an additional loss of lung tissue after resection contributes to their inability. Potential benefits of lung resection surgery should be balanced in relation to postoperative morbidity and mortality. PMID:25568542
Dynamic chest radiography: flat-panel detector (FPD) based functional X-ray imaging.
Tanaka, Rie
2016-07-01
Dynamic chest radiography is a flat-panel detector (FPD)-based functional X-ray imaging, which is performed as an additional examination in chest radiography. The large field of view (FOV) of FPDs permits real-time observation of the entire lungs and simultaneous right-and-left evaluation of diaphragm kinetics. Most importantly, dynamic chest radiography provides pulmonary ventilation and circulation findings as slight changes in pixel value even without the use of contrast media; the interpretation is challenging and crucial for a better understanding of pulmonary function. The basic concept was proposed in the 1980s; however, it was not realized until the 2010s because of technical limitations. Dynamic FPDs and advanced digital image processing played a key role for clinical application of dynamic chest radiography. Pulmonary ventilation and circulation can be quantified and visualized for the diagnosis of pulmonary diseases. Dynamic chest radiography can be deployed as a simple and rapid means of functional imaging in both routine and emergency medicine. Here, we focus on the evaluation of pulmonary ventilation and circulation. This review article describes the basic mechanism of imaging findings according to pulmonary/circulation physiology, followed by imaging procedures, analysis method, and diagnostic performance of dynamic chest radiography.
Nonparametric spirometry reference values for Hispanic Americans.
Glenn, Nancy L; Brown, Vanessa M
2011-02-01
Recent literature sites ethnic origin as a major factor in developing pulmonary function reference values. Extensive studies established reference values for European and African Americans, but not for Hispanic Americans. The Third National Health and Nutrition Examination Survey defines Hispanic as individuals of Spanish speaking cultures. While no group was excluded from the target population, sample size requirements only allowed inclusion of individuals who identified themselves as Mexican Americans. This research constructs nonparametric reference value confidence intervals for Hispanic American pulmonary function. The method is applicable to all ethnicities. We use empirical likelihood confidence intervals to establish normal ranges for reference values. Its major advantage: it is model free, but shares asymptotic properties of model based methods. Statistical comparisons indicate that empirical likelihood interval lengths are comparable to normal theory intervals. Power and efficiency studies agree with previously published theoretical results.
The effect of scoliosis surgery on pulmonary function in spinal muscular atrophy type II patients.
Chou, Shih-Hsiang; Lin, Gau-Tyan; Shen, Po-Chih; Lue, Yi-Jing; Lu, Cheng-Chang; Tien, Yin-Chun; Lu, Yen-Mou
2017-06-01
Various results of the previous literature related to surgical effect on pulmonary function of spinal muscular atrophy (SMA) patients might be due to different SMA type, different fusion level and technique. The aim of this study was to determine the value of scoliosis surgery for SMA type II patients with regard to pulmonary function, under the same fusion level, fusion technique and average long-term follow-up. Ten SMA II patients who underwent spinal correction procedures from 1993 to 2010 were identified. Data on clinical features and pulmonary function, including forced vital capacity (FVC) and forced expiratory volume in 1st second (FEV 1 ), were collected. The data on pulmonary function were divided into preoperative, postoperative short-term (0-5 years), mid-term (5-10 years), and long-term (>10 years). Statistical comparisons were made using the Wilcoxon test for pulmonary function and body weight analysis. Questions were answered by parents on how surgery influenced the frequency of respiratory infection and the ability to sit at school. The average length of postoperative pulmonary function follow-up was 12.3 years (range 4.9-15.9 years). There was no significant difference in FVC or FEV 1 between preoperative and each postoperative period. However, a significant decline from mid-term to long-term was observed (p = 0.028). Body weight increased significantly in all postoperative periods and was moderately correlated to pulmonary function (r = 0.526 for FVC). The answers to the questionnaire revealed that 80% of the patients had obvious improvement in the frequency of respiratory infection and 100% were tolerable sitting at school. Surgical correction for scoliosis in SMA II patients results in pulmonary function being maintained during long-term follow-up. In addition, the advantages of surgery also include body weight gain, better sitting tolerance, and reduced frequency of respiratory infection.
The efficacy of incentive spirometry in patients with COPD.
Basoglu, Ozen Kacmaz; Atasever, Alev; Bacakoglu, Feza
2005-06-01
Although incentive spirometry (IS) is frequently used to prevent postoperative pulmonary complications, its efficacy in patients with COPD has not been documented. The aim of this study was to evaluate the effects of IS on pulmonary function tests, arterial blood gases, dyspnoea and health-related quality of life in patients hospitalized for COPD. A total of 27 consecutive patients (mean age, 68.4 +/- 7.9 years; 26 males) admitted for COPD exacerbations were recruited for the study. In total, 15 (IS treatment group) used IS for 2 months, together with medical treatment. The remaining 12 (medical treatment group) were given only medical treatment. Pulmonary function and blood gases were measured. Assessment of dyspnoea by visual analogue scale (VAS) and quality of life using the St. George's Respiratory Questionnaire (SGRQ) were performed at admission and after 2 months of treatment. The activity, impact and total scores for the SGRQ improved (all P < or = 0.0001), PaCO2 values decreased (P = 0.02), PaO2 and PAO2 values increased (P = 0.02 and P = 0.01, respectively) in the IS treatment group. However, there were no significant differences between the measurements made pretreatment and after 2 months of medical therapy in the medical treatment group, with regards to pulmonary function, blood gases, SGRQ scores and VAS. The use of IS appears to improve arterial blood gases and health-related quality of life in patients with COPD exacerbations, although it does not alter pulmonary function parameters.
Le Roux, Pierre-Yves; Siva, Shankar; Steinfort, Daniel P; Callahan, Jason; Eu, Peter; Irving, Lou B; Hicks, Rodney J; Hofman, Michael S
2015-11-01
Pulmonary function tests (PFTs) are routinely used to assess lung function, but they do not provide information about regional pulmonary dysfunction. We aimed to assess correlation of quantitative ventilation-perfusion (V/Q) PET/CT with PFT indices. Thirty patients underwent V/Q PET/CT and PFT. Respiration-gated images were acquired after inhalation of (68)Ga-carbon nanoparticles and administration of (68)Ga-macroaggregated albumin. Functional volumes were calculated by dividing the volume of normal ventilated and perfused (%NVQ), unmatched and matched defects by the total lung volume. These functional volumes were correlated with forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), FEV1/FVC, and diffusing capacity for carbon monoxide (DLCO). All functional volumes were significantly different in patients with chronic obstructive pulmonary disease (P < 0.05). FEV1/FVC and %NVQ had the highest correlation (r = 0.82). FEV1 was also best correlated with %NVQ (r = 0.64). DLCO was best correlated with the volume of unmatched defects (r = -0.55). Considering %NVQ only, a cutoff value of 90% correctly categorized 28 of 30 patients with or without significant pulmonary function impairment. Our study demonstrates strong correlations between V/Q PET/CT functional volumes and PFT parameters. Because V/Q PET/CT is able to assess regional lung function, these data support the feasibility of its use in radiation therapy and preoperative planning and assessing pulmonary dysfunction in a variety of respiratory diseases. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Pulmonary function in adolescents with ataxia telangiectasia.
McGrath-Morrow, Sharon; Lefton-Greif, Maureen; Rosquist, Karen; Crawford, Thomas; Kelly, Amber; Zeitlin, Pamela; Carson, Kathryn A; Lederman, Howard M
2008-01-01
Pulmonary complications are common in adolescents with ataxia telangiectasia (A-T), however objective measurements of lung function may be difficult to obtain because of underlying bulbar weakness, tremors, and difficulty coordinating voluntary respiratory maneuvers. To increase the reliability of pulmonary testing, minor adjustments were made to stabilize the head and to minimize leaks in the system. Fifteen A-T adolescents completed lung volume measurements by helium dilution. To assess for reproducibility of spirometry testing, 10 A-T adolescents performed spirometry on three separate occasions. Total lung capacity (TLC) was normal or just mildly decreased in 12/15 adolescents tested. TLC correlated positively with functional residual capacity (FRC), a measurement independent of patient effort (R2=0.71). The majority of individuals had residual volumes (RV) greater than 120% predicted (10/15) and slow vital capacities (VC) less than 70% predicted (9/15). By spirometry, force vital capacity (FVC) and forced expiratory volume in 1 sec (FEV1) values were reproducible in the 10 individuals who underwent testing on three separate occasions (R=0.97 and 0.96 respectively). Seven of the 10 adolescents had FEV1/FVC ratios>90%. Lung volume measurements from A-T adolescents revealed near normal TLC values with increased RV and decreased VC values. These findings indicate a decreased ability to expire to residual volume rather then a restrictive defect. Spirometry was also found to be reproducible in A-T adolescents suggesting that spirometry testing may be useful for tracking changes in pulmonary function over time in this population. Copyright (c) 2007 Wiley-Liss, Inc.
Pulmonary Catherization Data Correlate Poorly with Renal Function in Heart Failure.
Masha, Luke; Stone, James; Stone, Danielle; Zhang, Jun; Sheng, Luo
2018-04-10
The mechanisms of renal dysfunction in heart failure are poorly understood. We chose to explore the relationship of cardiac filling pressures and cardiac index (CI) in relation to renal dysfunction in advanced heart failure. To determine the relationship between renal function and cardiac filling pressures using the United Network of Organ Sharing (UNOS) pulmonary artery catherization registry. Patients over the age of 18 years who were listed for single-organ heart transplantation were included. Exclusion criteria included a history of mechanical circulatory support, previous transplantation, any use of renal replacement therapy, prior history of malignancy, and cardiac surgery, amongst others. Correlations between serum creatinine (SCr) and CI, pulmonary capillary wedge pressure (PCWP), pulmonary artery systolic pressure (PASP), and pulmonary artery diastolic pressure (PADP) were assessed by Pearson correlation coefficients and simple linear regression coefficients. Pearson correlation coefficients between SCr and PCWP, PASP, and PADP were near zero with values of 0.1, 0.07, and 0.08, respectively (p < 0.0001). A weak negative correlation coefficient between SCr and CI was found (correlation coefficient, -0.045, p = 0.027). In a subgroup of young patients unlikely to have noncardiac etiologies, no significant correlations between these values were identified. These findings suggest that, as assessed by pulmonary artery catherization, none of the factors - PCWP, PASP, PADP, or CI - play a prominent role in cardiorenal syndromes. © 2018 S. Karger AG, Basel.
Danielsson, Aina J; Ekerljung, Linda; Hallerman, Kerstin Lofdahl
2015-09-01
Consecutive patients with idiopathic scoliosis diagnosed before age 10 attended a clinical follow-up at least 10 years after treatment. To evaluate the pulmonary function in adulthood after treatment with brace or surgery before maturity. Long-term studies of these patients have not been published. One hundred twenty-four patients (69% of the original group) underwent radiography, spirometry, and answered symptom questionnaires. A total of 73 patients had spirometries before treatment enabling longitudinal evaluation. Overall, 68 braced only (BT) and 56 surgically treated (ST) were analyzed in detail. A population-based control group was used. At follow-up, the mean age was 41.5 years and the mean curve size 36 degrees (26% of the curves >45 degrees). The full patient group had a significantly reduced pulmonary function (as measured by the forced vital capacity [FVC], percentage of predicted) compared with the control group, mean 85% versus 102% (p < .0001). Both subgroups of BT and ST patients showed a significant reduction, more in the ST than the BT group (means 79% and 90%, respectively, p = .0003). The most important risk factor for a low lung function at follow-up was a low initial FVC value. Initial curve size correlated with pulmonary function both before treatment and at follow-up. Most surgically treated patients, who had larger curves before treatment, did not improve their pulmonary function after surgery. Both braced and surgically treated patients had reduced pulmonary function at the age of around 40 years. The pulmonary function did not worsen over time in most patients. There was no difference in terms of symptoms between patient groups and controls. Initial curve size was found to be of great importance for pulmonary function. Initial spirometry and follow-up in selected patients is important. III. Copyright © 2015 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.
Schoonbeek, Rosanne C; Takebayashi, Satoshi; Aoki, Chikashi; Shimaoka, Toru; Harris, Matthew A; Fu, Gregory L; Kim, Timothy S; Dori, Yoav; McGarvey, Jeremy; Litt, Harold; Bouma, Wobbe; Zsido, Gerald; Glatz, Andrew C; Rome, Jonathan J; Gorman, Robert C; Gorman, Joseph H; Gillespie, Matthew J
2016-10-01
Pulmonary insufficiency is the nexus of late morbidity and mortality after transannular patch repair of tetralogy of Fallot. This study aimed to establish the feasibility of implantation of the novel Medtronic Harmony transcatheter pulmonary valve (hTPV) and to assess its effect on pulmonary insufficiency and ventricular function in an ovine model of chronic postoperative pulmonary insufficiency. Thirteen sheep underwent baseline cardiac magnetic resonance imaging, surgical pulmonary valvectomy, and transannular patch repair. One month after transannular patch repair, the hTPV was implanted, followed by serial magnetic resonance imaging and computed tomography imaging at 1, 5, and 8 month(s). hTPV implantation was successful in 11 animals (85%). There were 2 procedural deaths related to ventricular fibrillation. Seven animals survived the entire follow-up protocol, 5 with functioning hTPV devices. Two animals had occlusion of hTPV with aneurysm of main pulmonary artery. A strong decline in pulmonary regurgitant fraction was observed after hTPV implantation (40.5% versus 8.3%; P=0.011). Right ventricular end diastolic volume increased by 49.4% after transannular patch repair (62.3-93.1 mL/m 2 ; P=0.028) but was reversed to baseline values after hTPV implantation (to 65.1 mL/m 2 at 8 months, P=0.045). Both right ventricular ejection fraction and left ventricular ejection fraction were preserved after hTPV implantation. hTPV implantation is feasible, significantly reduces pulmonary regurgitant fraction, facilitates right ventricular volume improvements, and preserves biventricular function in an ovine model of chronic pulmonary insufficiency. This percutaneous strategy could potentially offer an alternative for standard surgical pulmonary valve replacement in dilated right ventricular outflow tracts, permitting lower risk, nonsurgical pulmonary valve replacement in previously prohibitive anatomies. © 2016 American Heart Association, Inc.
Lin, Shuan-Pei; Shih, Shou-Chuan; Chuang, Chih-Kuang; Lee, Kuo-Sheng; Chen, Ming-Ren; Niu, Dau-Ming; Chiu, Pao Chin; Lin, Shio Jean; Lin, Hsiang-Yu
2014-03-01
The mucopolysaccharidoses (MPS) comprise a group of inherited lysosomal storage disorders characterized by deficiencies in enzymes catalyzing the degradation of glycosaminoglycans. Impairment of pulmonary function is an important health problem for patients with MPS. However, there are few published reports on the prevalence and severity of pulmonary dysfunction in relation to age and treatment in this disorder. To evaluate pulmonary function in patients with MPS, we performed spirometry in 35 patients (22 males and 13 females; 1 with MPS I, 12 with MPS II, 16 with MPS IVA, and 6 with MPS VI; mean age, 14.6 ± 5.9 years; age range, 6.4 years to 33 years). Forced vital capacity (FVC), forced expired volume in 1 sec (FEV1), FEV1 to FVC ratio (FEV1/FVC), peak expiratory flow (PEF), and mean forced expiratory flow during the middle half of FVC (FEF25-75% ) were measured. Mean FVC, FEV1 , PEF, and FEF25-75% were 74.2%, 73.9%, 64.7%, and 37.1% of the predicted values, respectively. By spirometric classification, 32 patients (91%) had small airway disease (FEF25-75% < 65%), 17 (48%) had restrictive lung disease, and 3 (9%) had obstructive lung disease. Percent predicted FVC, FEV1 , and PEF, as well as FEV1 /FVC, were all negatively correlated with age (P < 0.01), such that pubertal and post-pubertal patients had significantly lower values than younger patients. Of eight attenuated MPS II and VI patients who underwent follow-up pulmonary function testing after receiving enzyme replacement therapy (ERT) for 1.5-7.4 years, six showed improvements in % predicted FVC and five improved in % predicted FEV1 . Our additional characterization of the types and prevalence of pulmonary function abnormalities seen in MPS patients should be useful for clinical care. © 2013 Wiley Periodicals, Inc.
Manoharan, Sujatha C; Ramakrishnan, Swaminathan
2009-10-01
In this work, prediction of forced expiratory volume in pulmonary function test, carried out using spirometry and neural networks is presented. The pulmonary function data were recorded from volunteers using commercial available flow volume spirometer in standard acquisition protocol. The Radial Basis Function neural networks were used to predict forced expiratory volume in 1 s (FEV1) from the recorded flow volume curves. The optimal centres of the hidden layer of radial basis function were determined by k-means clustering algorithm. The performance of the neural network model was evaluated by computing their prediction error statistics of average value, standard deviation, root mean square and their correlation with the true data for normal, restrictive and obstructive cases. Results show that the adopted neural networks are capable of predicting FEV1 in both normal and abnormal cases. Prediction accuracy was more in obstructive abnormality when compared to restrictive cases. It appears that this method of assessment is useful in diagnosing the pulmonary abnormalities with incomplete data and data with poor recording.
Swift, Andrew J; Rajaram, Smitha; Campbell, Michael J; Hurdman, Judith; Thomas, Steve; Capener, Dave; Elliot, Charlie; Condliffe, Robin; Wild, Jim M; Kiely, David G
2014-01-01
There are limited data on the prognostic value of cardiovascular magnetic resonance measurements in idiopathic pulmonary arterial hypertension, with no studies investigating the impact of correction of cardiovascular magnetic resonance indices for age and sex on prognostic value. Consecutive patients with idiopathic pulmonary arterial hypertension underwent cardiovascular magnetic resonance imaging at 1.5T. Steady-state free precession cardiac volumes and mass measurements were corrected for age, sex, and body surface area according to reference data and prognostic significance assessed. A total of 80 patients with idiopathic pulmonary arterial hypertension were identified, and 23 patients died during the mean follow-up of 32±14 months. Corrected for age, sex, and body surface area, right ventricular end-systolic volume (P=0.004) strongly predicted mortality, independent of World Health Organization functional class, mean right atrial pressure, cardiac index, and mixed venous oxygen saturations. Consideration should be given to correcting cardiovascular magnetic resonance measures for age, sex, and body surface area, particularly given the changing demographics of patients with idiopathic pulmonary arterial hypertension. Corrected right ventricular end-systolic volume is a strong prognostic marker in idiopathic pulmonary arterial hypertension, independent of invasively derived measurements, mean right atrial pressure cardiac index, and mixed venous oxygen saturations.
Yu, Jie; Zhang, Longju; Luo, Ya; Tang, Yin; Tuo, Fangxu; Yang, Jiaqi; Xu, Jie
2017-04-01
To assess the association of indoor environmental risk factors with respiratory function among adults in an acid rain-plagued city in China where coal use is frequent. The subjects were randomly selected in the winter season. Information on selected home environmental factors was collected through administered questionnaires. Additionally, pulmonary function tests, including Forced Vital Capacity (FVC), Forced Expiratory Volume in 1 s (FEV 1 ), FEV 1 /FVC and Peak Expiratory Flow Rate (PEFR) were also performed in participants. This study showed that, among a variety of risk factors, coal fuel use, cooking oil fumes and active and passive smoking exposure together with asthma in childhood were important factors for deterioration of pulmonary function among adults in the winter season (p < 0.05). Additionally, subjects whose kitchen was located in the living room or bedroom, who opened their windows only occasionally or never, who noted the presence of cooking oil fumes and pests, whose bedroom was shared by 3 or more residents and who kept pets tended to exhibit lower values of FVC, FEV 1 and PEFR values compared with non-exposed counterparts (p < 0.05). This study demonstrated impaired pulmonary function among adults who were exposed to indoor risk factors, such as coal fires and cigarette smoking compared to non-users in the winter season and emphasizes the need for public health efforts to decrease exposure to indoor air pollution.
[System analytical approach of lung function and hemodynamics].
Naszlady, Attila; Kiss, Lajos
2009-02-15
The authors critically analyse the traditional views in physiology and complete them with new statements based on computer model simulations of lung function and of hemodynamics. Conclusions are derived for the clinical practice as follows: the four-dimensional function curves are similar in both systems; there is a "waterfall" zone in the pulmonary blood perfusion; the various time constants of pulmonary regions can modify the blood gas values; pulmonary capillary pressure is equal to pulmonary arterial diastole pressure; heart is not a pressure pump, but a flow source; ventricles are loaded by the input impedance of the arterial systems and not by the total vascular (ohmlike) resistance; optimum heart rate in rest depends on the length of the aorta; this law of heart rate, based on the principle of resonance is valid along the mammalian allometric line; tachycardia decreases the input impedance; using positive end expiratory pressure respirators the blood gas of pulmonary artery should be followed; coronary circulation should be assessed in beat per milliliter, the milliliter per minute may be false. These statements are compared to related references.
Pulmonary function improvement after vertebral column resection for severe spinal deformity.
Bumpass, David B; Lenke, Lawrence G; Bridwell, Keith H; Stallbaumer, Jeremy J; Kim, Yongjung J; Wallendorf, Michael J; Min, Woo-Kie; Sides, Brenda A
2014-04-01
Retrospective review of prospectively accrued cohorts. We hypothesized that posterior-only vertebral column resection (PVCR) would result in improved postoperative pulmonary function, avoiding pulmonary insults from combined anterior/posterior approaches. Pulmonary function after PVCR for severe spinal deformity has not been previously studied. Previous studies have demonstrated impaired pulmonary performance after combined anterior/posterior fusions. Serial pulmonary function testing (PFTs) in 49 patients (27 pediatric, 22 adult) who underwent PVCR at a single institution was reviewed. Mean age at surgery was 28.7 years (range, 8-74 yr), and mean follow-up was 32 months (range, 23-64 mo). Thoracic PVCRs (T5-T11) were performed in 31 patients and thoracolumbar PVCRs (T12-L5) in 18 patients. Pediatric patients who underwent PVCR experienced both increased mean forced vital capacity (FVC) (2.10-2.43 L, P = 0.0005) and forced expiratory volume in 1 second (FEV1) (1.71-1.98 L, P = 0.001). There were no significant differences in percent-predicted values for FVC (69%-66%, P = 0.51) or FEV1 (64%-63%, P = 0.77). In adult patients, there were no significant changes in FVC (2.73-2.61 L, P = 0.35) or FEV1 (2.22-2.07 L, P = 0.51) after PVCR; also, changes in adult percent-predicted values for FVC (79%-76%, P = 0.47) and FEV1 (78%-74%, P = 0.40) were not significant. In pediatric patients who underwent PVCR, improved PFTs were correlated with younger age (P = 0.02), diagnosis of angular kyphosis (P ≤ 0.0001), no previous spine surgery (P = 0.04), and preoperative halo-gravity traction (P = 0.02). Comparison of PFT changes between patients who underwent PVCR and a control group who underwent combined anterior/posterior approaches revealed no significant differences. In pediatric patients, PVCR resulted in small but significant improvements in postoperative FVC and FEV1. In adult patients, no significant increases in PFTs were found. Patients who have the greatest potential for lung and thoracic cage growth after spinal correction are most likely to have improved pulmonary function after PVCR.
Process of pulmonary rehabilitation and program organization.
Wouters, E F M; Augustin, I M L
2011-09-01
Pulmonary rehabilitation programs are highly directed to return patients suffering from chronic lung diseases to a state of self-help. These programs are largely organized as temporary interventions in a highly fragmented delivery care system for patients with chronic respiratory conditions. In an optimal health care organizational structure, pulmonary rehabilitation needs to be considered as an essential part of an individualized, integrated care process, organized from the vantage point of the patient and the patients'health continuum. Pulmonary rehabilitation programs need to become organized as patient-centered care, respectful of and responsive to individual patient preferences, needs and values. Partnering and communication skills are considered as drivers for successful rehabilitation. Assessment is considered as the cornerstone to evaluate the individual needs and problems in order to develop an individualized intervention. Pulmonary rehabilitation programs need to move away from a supply-driven functional organizational structure towards integrated structures, including the full range of medical expertise, technical skills and specialized facilities needed to compete on added value in the management of patients with chronic respiratory diseases.
Maioli, Maria Christina Paixão; Soares, Andrea Ribeiro; Bedirian, Ricardo; Alves, Ursula David; de Lima Marinho, Cirlene; Lopes, Agnaldo José
2015-01-01
Objective To evaluate the association between clinical, pulmonary, and cardiovascular findings in patients with sickle cell disease and, secondarily, to compare these findings between sickle cell anemia patients and those with other sickle cell diseases. Methods Fifty-nine adults were included in this cross-sectional study; 47 had sickle cell anemia, and 12 had other sickle cell diseases. All patients underwent pulmonary function tests, chest computed tomography, and echocardiography. Results Abnormalities on computed tomography, echocardiography, and pulmonary function tests were observed in 93.5%, 75.0%; and 70.2% of patients, respectively. A higher frequency of restrictive abnormalities was observed in patients with a history of acute chest syndrome (85% vs. 21.6%; p-value < 0.0001) and among patients with increased left ventricle size (48.2% vs. 22.2%; p-value = 0.036), and a higher frequency of reduced respiratory muscle strength was observed in patients with a ground-glass pattern (33.3% vs. 4.3%; p-value = 0.016). Moreover, a higher frequency of mosaic attenuation was observed in patients with elevated tricuspid regurgitation velocity (61.1% vs. 24%; p-value = 0.014). Compared to patients with other sickle cell diseases, sickle cell anemia patients had suffered increased frequencies of acute pain episodes, and acute chest syndrome, and exhibited mosaic attenuation on computed tomography, and abnormalities on echocardiography. Conclusion A significant interrelation between abnormalities of the pulmonary and cardiovascular systems was observed in sickle cell disease patients. Furthermore, the severity of the cardiopulmonary parameters among patients with sickle cell anemia was greater than that of patients with other sickle cell diseases. PMID:26969771
Nikolaidis, Lazaros; Memon, Nabeel; O'Murchu, Brian
2015-02-01
We describe the case of a 54-year-old man who presented with exertional dyspnea and fatigue that had worsened over the preceding 2 years, despite a normally functioning bioprosthetic aortic valve and stable, mild left ventricular dysfunction (left ventricular ejection fraction, 0.45). His symptoms could not be explained by physical examination, an extensive biochemical profile, or multiple cardiac and pulmonary investigations. However, abnormal cardiopulmonary exercise test results and a right heart catheterization-combined with the use of a symptom-limited, bedside bicycle ergometer-revealed that the patient's exercise-induced pulmonary artery hypertension was out of proportion to his compensated left heart disease. A trial of sildenafil therapy resulted in objective improvements in hemodynamic values and functional class.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chinet, T.; Dusser, D.; Labrune, S.
1990-02-01
Respiratory epithelial clearance of {sup 99m}Tc-DTPA (RC-Tc-DTPA) and pulmonary function tests (PFT) were determined at intervals of 6 or 12 months in 37 untreated, nonsmoking patients with sarcoidosis over a period of 6 to 36 months. PFT included the measurements of total lung capacity (TLC), vital capacity (VC), FEV1, and diffusing capacity for carbon monoxide. No difference was found between the respiratory clearance of {sup 113m}In-DTPA (2.25 +/- 1.00%/min) and RC-Tc-DTPA (2.29 +/- 1.11%/min) in eight patients with pulmonary sarcoidosis. Pulmonary function decreased 15% or more in at least 2 function tests during 11 follow-up periods, but it remained stablemore » during 47 follow-up periods. In patients whose lung function deteriorated, RC-Tc-DTPA increased to 3.51 +/- 1.55%/min; in contrast, in patients whose lung function remained stable, regardless of the initial values, RC-Tc-DTPA was normal (1.00 +/- 0.50%/min; p less than 0.001). In eight patients who were treated with corticosteroids, RC-Tc-DTPA decreased from 3.48 +/- 1.31%/min to 1.56 +/- 0.64%/min (p less than 0.001), and PFT improved. We conclude that in nonsmokers with pulmonary sarcoidosis, increased RC-Tc-DTPA is not related to dissociation of 99mTc from DTPA, RC-Tc-DTPA is increased when pulmonary function decreases, and, when increased, RC-Tc-DTPA decreases with corticosteroid therapy.« less
Liao, Hua; Shen, Ying; Wang, Pengjun
2015-05-01
To study the pulmonary function and nasal resistance characteristics of patients with chronic nose-sinusitis and nasal polyps (CRSwNP), to explore the evaluation role of nasal resistance in nasal ventilation function and the effect of endoscopic sinus surgery on pulmonary function in patients with CRSwNP. Fifty CRSwNP patients that met the study criteria were selected . The patients were performed endoscopic surgeries according to Messerklinger surgical procedures under general anesthesia. Extent of surgery was based on preoperative CT showing the range of the lesion of disease and endoscopic findings. Perioperative treatments contained intranasal corticosteroids, cephalosporin or penicillin antibiotics, nasal irrigation and other treatments. Main outcome measures included visual analog scale (VAS), endoscopic Lind-Kennedy scores, nasal resistence, pulmonary function in patientsone week before and after surgery, three months and six months after surgery. Pulmonary function includes forced expiratory volume in one second (FEV1), forced vital capacity FEV1/FVC and peak expiratory flow (PEF). The study found that there were significantly positive correlations among VAS score, Lund-Kennedy score and nasal resistance (P < 0.05) in CRSwNP patients, but there is a significantly negative correlation between VAS score, Lund-Kennedy score, nasal resistance and pulmonary function indexes of FEV1, FVC and PEF (P < 0.05). The VAS score, Lund-Kennedy score and nasal resistance values of CRSwNP patients were decreased significantly after comprehensive treatments with nasal endoscopic operation as the major one, the difference was statistically different (P < 0.05). And the pulmonary function indexs (FEV1, FVC, PEF) were significantly increased after surgery in CRSwNP patients. The nasal resistance can objectively and reliably reflect the degree of nasal congestion and the recovery of nasal function in CRSwNP patients after endoscopic sinus surgery. The detection method of nasal resistance is simple. Functional endoscopic sinus surgery can effectively improve the pulmonary ventilation function in CRSwNP patients, providing some clinical references about the prevention and treatment of CRS related lower respiratory disease.
Sandur, V; Murugesh, M; Banait, V; Rathi, P M; Bhatia, S J; Joshi, J M; Kate, A
2014-01-01
The hypothesis that GER can trigger or exacerbate asthma is supported by several clinical trials that have shown amelioration in asthma symptoms and/or an improvement in pulmonary function after antireflux therapy. To investigate the prevalence of GER in patients with difficult to control asthma and to determine the effect of omeprazole on asthma symptoms, reflux symptoms, pulmonary function and on the requirement of asthma medications. Patients with difficult to control asthma were recruited into the study. All patients underwent esophageal manometry and 24 hour esophageal pH monitoring. Pulmonary function tests were done before and after treatment. The severity of asthma and reflux was assessed by a 1 week pulmonary symptom score(PSS) and reflux symptom score(RSS) respectively before and after treatment. Those who had an abnormal pH study (pH <4 in the distal esophagus for >5% of the time) underwent anti-GER treatment with lifestyle changes, and a proton pump inhibitor (omeprazole 40 mg, bid) for 3 months. Asthma medications were added or deleted based on severity of asthma. Out of 250 asthmatic patients screened, forty patients fulfilled the inclusion criteria. Twenty eight of 40 patients(70%) were diagnosed to have GERD. Of the patients 28 with GER, 8 patients(28.5%) had no reflux symptoms. On 24 hr pH metry, the percentage time pH <4.0 was 10.81 ± 4.72 and 1.11 ± 1.21; Deemester score was 37.65 ± 14.54 and 4.89 ± 6.39 (p-value is 0.0001) in GERD and non-GERD patients respectively.In GERD group, post treatment reflux symptom score(RSS) improved from 22.39 ± 14.99 to 1.04 ± 1.07, pulmonary symptom score(PSS) improved from 27.14 ± 7.49 to 13.82 ± 4.21 and night time asthma symptom score(NASS) improved from 6.71 ± 1.80 to 3.04 ± 1.23 (p-value <0.0001). After treatment, FEV1 and PEFR increased from 1.38 ± 0.57 and 4.14 ± 1.97 to 1.47 ± 0.54 and 5.56 ± 1.72, respectively (p-value 0.00114). PPI therapy improves nocturnal asthma symptoms, daytime asthma symptoms, pulmonary function and decreases requirement of asthma medications in these patients.
Fibroblast growth factor 10 haploinsufficiency causes chronic obstructive pulmonary disease.
Klar, Joakim; Blomstrand, Peter; Brunmark, Charlott; Badhai, Jitendra; Håkansson, Hanna Falk; Brange, Charlotte Sollie; Bergendal, Birgitta; Dahl, Niklas
2011-10-01
Genetic factors influencing lung function may predispose to chronic obstructive pulmonary disease (COPD). The fibroblast growth factor 10 (FGF10) signalling pathway is critical for lung development and lung epithelial renewal. The hypothesis behind this study was that constitutive FGF10 insufficiency may lead to pulmonary disorder. Therefore investigation of the pulmonary functions of patients heterozygous for loss of function mutations in the FGF10 gene was performed. The spirometric measures of lung function from patients and non-carrier siblings were compared and both groups were related to matched reference data for normal human lung function. The patients show a significant decrease in lung function parameters when compared to control values. The average FEV1/IVC quota (FEV1%) for the patients is 0.65 (80% of predicted) and reversibility test using Terbutalin resulted in a 3.7% increase in FEV1. Patients with FGF10 haploinsufficiency have lung function parameters indicating COPD. A modest response to Terbutalin confirms an irreversible obstructive lung disease. These findings support the idea that genetic variants affecting the FGF10 signalling pathway are important determinants of lung function that may ultimately contribute to COPD. Specifically, the results show that FGF10 haploinsufficiency affects lung function measures providing a model for a dosage sensitive effect of FGF10 in the development of COPD.
Florida Red Tide Toxins (Brevetoxins) and Longitudinal Respiratory Effects in Asthmatics.
Bean, Judy A; Fleming, Lora E; Kirkpatrick, Barbara; Backer, Lorraine C; Nierenberg, Kate; Reich, Andrew; Cheng, Yung Sung; Wanner, Adam; Benson, Janet; Naar, Jerome; Pierce, Richard; Abraham, William M; Kirkpatrick, Gary; Hollenbeck, Julie; Zaias, Julia; Mendes, Eliana; Baden, Daniel G
2011-09-01
Having demonstrated significant and persistent adverse changes in pulmonary function for asthmatics after 1 hour exposure to brevetoxins in Florida red tide (Karenia brevis bloom) aerosols, we assessed the possible longer term health effects in asthmatics from intermittent environmental exposure to brevetoxins over 7 years. 125 asthmatic subjects were assessed for their pulmonary function and reported symptoms before and after 1 hour of environmental exposure to Florida red tide aerosols for upto 11 studies over seven years. As a group, the asthmatics came to the studies with normal standardized percent predicted pulmonary function values. The 38 asthmatics who participated in only one exposure study were more reactive compared to the 36 asthmatics who participated in ≥4 exposure studies. The 36 asthmatics participating in ≥4 exposure studies demonstrated no significant change in their standardized percent predicted pre-exposure pulmonary function over the 7 years of the study. These results indicate that stable asthmatics living in areas with intermittent Florida red tides do not exhibit chronic respiratory effects from intermittent environmental exposure to aerosolized brevetoxins over a 7 year period.
Minakata, Yoshiaki; Morishita, Yukiko; Ichikawa, Tomohiro; Akamatsu, Keiichiro; Hirano, Tsunahiko; Nakanishi, Masanori; Matsunaga, Kazuto; Ichinose, Masakazu
2015-01-01
Improvement in the daily physical activity (PA) is important for the management of chronic obstructive pulmonary disease (COPD). However, the effects of pharmacologic treatment on PA are not well understood. We evaluated the effects of additional medications, including bronchodilator with or without inhaled corticosteroid, based on airflow limitation and breathlessness on the PA in COPD patients and the factors that could predict or affect the improvement in PA. A prospective non-randomized observational study was employed. Twenty-one COPD subjects without any other diseases that might reduce PA were recruited. The PA was measured with a triaxial accelerometer for 2 weeks, and pulmonary function tests and incremental shuttle walking tests were administered before and after 4-week treatment with an additional medication. Bronchodilation was obtained by additional medication. The mean values of PA evaluated by metabolic equivalents (METs) at ≥3.0 METs and the duration of PA at ≥3.0 METs and ≥3.5 METs were improved by medication. The % change in the duration of PA at ≥3.5 METs was significantly correlated with the baseline functional residual capacity (FRC), residual volume, and inspiratory capacity/total lung capacity. However, the % change in the duration of PA at any intensity was not correlated with the % changes of any values of the pulmonary function tests or incremental shuttle walking test except the PA at ≥2.5 METs with FRC. Medication could improve the PA in patients with COPD, especially at a relatively high intensity of activity when medication was administered based on airflow limitation and breathlessness. The improvement was seen in the patients with better baseline lung volume, but was not correlated with the improvements in the pulmonary function tests or exercise capacity.
Bokov, P; Delclaux, C
2016-02-01
Resting pulmonary function tests (PFT) include the assessment of ventilatory capacity: spirometry (forced expiratory flows and mobilisable volumes) and static volume assessment, notably using body plethysmography. Spirometry allows the potential definition of obstructive defect, while static volume assessment allows the potential definition of restrictive defect (decrease in total lung capacity) and thoracic hyperinflation (increase in static volumes). It must be kept in mind that this evaluation is incomplete and that an assessment of ventilatory demand is often warranted, especially when facing dyspnoea: evaluation of arterial blood gas (searching for respiratory insufficiency) and measurement of the transfer coefficient of the lung, allowing with the measurement of alveolar volume to calculate the diffusing capacity of the lung for CO (DLCO: assessment of alveolar-capillary wall and capillary blood volume). All these pulmonary function tests have been the subject of an Americano-European Task force (standardisation of lung function testing) published in 2005, and translated in French in 2007. Interpretative strategies for lung function tests have been recommended, which define abnormal lung function tests using the 5th and 95th percentiles of predicted values (lower and upper limits of normal values). Thus, these recommendations need to be implemented in all pulmonary function test units. A methacholine challenge test will only be performed in the presence of an intermediate pre-test probability for asthma (diagnostic uncertainty), which is an infrequent setting. The most convenient exertional test is the 6-minute walk test that allows the assessment of walking performance, the search for arterial desaturation and the quantification of dyspnoea complaint. Copyright © 2015 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.
Santos, Bruna F A; Souza, Hugo C D; Miranda, Aline P B; Cipriano, Federico G; Gastaldi, Ada C
2016-01-01
To assess functional capacity in the preoperative phase of pulmonary surgery by comparing predicted and obtained values for the six-minute walk test (6MWT) in patients with and without postoperative pulmonary complication (PPC) METHOD: Twenty-one patients in the preoperative phase of open thoracotomy were evaluated using the 6MWT, followed by monitoring of the postoperative evolution of each participant who underwent the routine treatment. Participants were then divided into two groups: the group with PPC and the group without PPC. The results were also compared with the predicted values using reference equations for the 6MWT RESULTS: Over half (57.14%) of patients developed PPC. The 6MWT was associated with the odds for PPC (odds ratio=22, p=0.01); the group without PPC in the postoperative period walked 422.38 (SD=72.18) meters during the 6MWT, while the group with PPC walked an average of 340.89 (SD=100.93) meters (p=0.02). The distance traveled by the group without PPC was 80% of the predicted value, whereas the group with PPC averaged less than 70% (p=0.03), with more appropriate predicted values for the reference equations The 6MWT is an easy, safe, and feasible test for routine preoperative evaluation in pulmonary surgery and may indicate patients with a higher chance of developing PPC.
Wiessmann, K J
1975-09-05
The effects on pulmonary function of a slow-release preparation of an oral broncholytic drug (containing 350 mg aminophylline, released over eight hours) was tested on 26 patients in a double-blind trial. There was a marked reduction of airway resistance and stimulation of breathing with decreased dynamic work of breathing. Distinctly improved alveolar function was demonstrated especially in a fall of arterial CO2 tension, but in some cases there was probably an increase in distribution abnormality. Central haemodynamic changes with a decreased in pulmonary artery pressure and changes in the other values lasted for more than ten hours on the first day of treatment, and were demonstrable on the fourth day even before the drug was taken that day. The criteria of an effective broncholytic slow-release drug with sustained effect were thus fulfilled.
Ohkubo, Hirotsugu; Nakagawa, Hiroaki; Niimi, Akio
2018-01-01
Idiopathic pulmonary fibrosis (IPF) is the most common type of progressive idiopathic interstitial pneumonia in adults. Many computer-based image analysis methods of chest computed tomography (CT) used in patients with IPF include the mean CT value of the whole lungs, density histogram analysis, density mask technique, and texture classification methods. Most of these methods offer good assessment of pulmonary functions, disease progression, and mortality. Each method has merits that can be used in clinical practice. One of the texture classification methods is reported to be superior to visual CT scoring by radiologist for correlation with pulmonary function and prediction of mortality. In this mini review, we summarize the current literature on computer-based CT image analysis of IPF and discuss its limitations and several future directions. Copyright © 2017 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.
Piccinino, Cristina; Giubertoni, Ailia; Zanaboni, Jacopo; Gravellone, Miriam; Sola, Daniele; Rosso, Roberta; Ferrarotti, Lorena; Marino, Paolo Nicola
2017-11-01
Increased right atrial size is related to adverse prognosis in pulmonary hypertension. The potential incremental value of right atrial function assessment is still unclear. We tested the relationship between right atrial two-dimensional speckle-tracking echocardiography impairment and hemodynamic, functional and clinical deterioration in patients with pulmonary hypertension. We prospectively evaluated 36 patients (27 female, 9 male; mean age 68 ± 13 years) with suspected pulmonary hypertension undergoing right heart catheterization and 16 matched controls. All patients underwent baseline evaluation by New York Heart Association functional class, 6-min walking test, brain natriuretic peptide (BNP), and standard two-dimensional echocardiography in less than 48 h of right heart catheterization. Right atrial two-dimensional speckle-tracking echocardiography was assessed by averaging all segments in standard four-chamber apical view. Right atrial global integral strain was significantly lower in patients compared with controls (11.40 ± 5.22% vs. 25.72 ± 5.95 P < 0.001). Moreover, right atrial global strain, but not right atrial area or volume, was correlated with invasively measured cardiac index (CI) (r = 0.72; P < 0.0001) and pulmonary vascular resistances in all patients, even though stronger in subjects with precapillary pulmonary hypertension (r = -0.42, P = 0.018; r = -0.54, P = 0.007 respectively; P = 0.007). It was also correlated with New York Heart Association (P = 0.027), BNP (P = 0.002), and 6-min walking test (P = 0.006). After multivariate analysis including right atrial volume, tricuspid annular plane systolic excursion, left atrial strain, and BNP, right atrial global strain showed the strongest correlation with CI. Area under the curve optimal cutoff for predicting CI at least 2.4 l/min/m was 17% (area under the curve: 0.83, sensitivity: 90%, specificity: 54%). Right atrial global strain can identify right atrial functional impairment before structural changes and may be implemented in a comprehensive, noninvasive right heart assessment for diagnosis and follow-up of pulmonary hypertension patients.
Zisman, David A.; Karlamangla, Arun S.; Kawut, Steven M.; Shlobin, Oksana A.; Saggar, Rajeev; Ross, David J.; Schwarz, Marvin I.; Belperio, John A.; Ardehali, Abbas; Lynch, Joseph P.; Nathan, Steven D.
2008-01-01
Background We have developed a method to screen for pulmonary hypertension (PH) in idiopathic pulmonary fibrosis (IPF) patients, based on a formula to predict mean pulmonary artery pressure (MPAP) from standard lung function measurements. The objective of this study was to validate this method in a separate group of IPF patients. Methods Cross-sectional study of 60 IPF patients from two institutions. The accuracy of the MPAP estimation was assessed by examining the correlation between the predicted and measured MPAPs and the magnitude of the estimation error. The discriminatory ability of the method for PH was assessed using the area under the receiver operating characteristic curve (AUC). Results There was strong correlation in the expected direction between the predicted and measured MPAPs (r = 0.72; p < 0.0001). The estimated MPAP was within 5 mm Hg of the measured MPAP 72% of the time. The AUC for predicting PH was 0.85, and did not differ by institution. A formula-predicted MPAP > 21 mm Hg was associated with a sensitivity, specificity, positive predictive value, and negative predictive value of 95%, 58%, 51%, and 96%, respectively, for PH defined as MPAP from right-heart catheterization > 25 mm Hg. Conclusions A prediction formula for MPAP using standard lung function measurements can be used to screen for PH in IPF patients. PMID:18198245
Modulation of Lung Function by Increased Nitric Oxide Production
Yadav, Ram Lochan; Yadav, Prakash Kumar
2017-01-01
Introduction Cigarette smoking reduces endogenous Nitric Oxide (NO) production by reducing Nitric Oxide Synthase (NOS) activity, which is one of the probable reason for increased rate of pulmonary diseases in smokers. Nitric oxide/oxygen blends are used in critical care to promote capillary and pulmonary dilation to treat several pulmonary vascular diseases. Among several supplements, the highest NOS activation has been proved for garlic with its unique mechanism of action. Aim To investigate the effect of dietary supplementation of NO producing garlic on pulmonary function of smokers. Materials and Methods The study was conducted on 40 healthy non-smoker (Group A) and 40 chronic smoker (Group B) males with matched age, height and weight. The pulmonary function tests- Forced Vital Capacity (FVC), Forced Expiratory Volume in one second (FEV1), FEV1/FVC ratio and Peak Expiratory Flow Rate (PEFR) were performed in non-smokers (Group A), smokers (Group B) and smokers after supplementation of approximately 4 gm of raw garlic (2 garlic cloves) per day for three months (Group C). Endogenous NO production was studied in smokers before and after garlic supplementation and in non-smokers without supplementation. The data obtained were compared between the groups using unpaired student’s t-test. The p-value considered significant at <0.05. Results Our results showed that FVC, FEV1, FEV1/FVC ratio and PEFR were reduced significantly along with a significant decreased NOS activity among smokers (Group B) when compared with non-smokers (Group A). Garlic supplementation significantly improved the pulmonary function tests in Group C in comparison to Group B by increasing NOS activity. Conclusion Dietary supplementation of garlic, which might be by increasing NOS activity, has significantly improved pulmonary functions in smokers. PMID:28764150
Benattia, Amira; Debeaumont, David; Guyader, Vincent; Tardif, Catherine; Peillon, Christophe; Cuvelier, Antoine; Baste, Jean-Marc
2016-06-01
Impaired respiratory function may prevent curative surgery for patients with non-small cell lung cancer (NSCLC). Video-assisted thoracoscopic surgery (VATS) reduces postoperative morbility-mortality and could change preoperative assessment practices and therapeutic decisions. We evaluated the relation between preoperative pulmonary function tests and the occurrence of postoperative complications after VATS pulmonary resection in patients with abnormal pulmonary function. We included 106 consecutive patients with ≤80% predicted value of presurgical expiratory volume in one second (FEV1) and/or diffusing capacity of carbon monoxide (DLCO) and who underwent VATS pulmonary resection for NSCLC from a prospective surgical database. Patients (64±9.5 years) had lobectomy (n=91), segmentectomy (n=7), bilobectomy (n=4), or pneumonectomy (n=4). FEV1 and DLCO preoperative averages were 68%±21% and 60%±18%. Operative mortality was 1.89%. Only FEV1 was predictive of postoperative complications [odds ratio (OR), 0.96; 95% confidence interval (CI), 0.926-0.991, P=0.016], but there was no determinable threshold. Twenty-five patients underwent incremental exercise testing. Desaturations during exercise (OR, 0.462; 95% CI, 0.191-0.878, P=0.039) and heart rate (HR) response (OR, 0.953; 95% CI, 0.895-0.993, P=0.05) were associated with postoperative complications. FEV1 but not DLCO was a significant predictor of pulmonary complications after VATS pulmonary resection despite a low rate of severe morbidity. Incremental exercise testing seems more discriminating. Further investigation is required in a larger patient population to change current pre-operative threshold in a new era of minimally invasive surgery.
Milburn, H J; Prentice, H G; du Bois, R M
1992-06-01
Lung function often deteriorates after bone marrow transplantation for haematological malignancies. Whether pulmonary function measurements are useful for monitoring patients' progress after transplantation and for alerting clinicians to the development of pneumonitis is uncertain. Serial pulmonary function measurements were made in 39 patients with a haematological malignancy, and the values from 18 recipients of T cell depleted allogeneic (n = 17) or autologous (n = 1) bone marrow transplants who developed interstitial pneumonitis were compared retrospectively with values from 21 recipients of allogeneic (n = 17) or autologous (n = 4) transplants who did not develop pneumonitis. Lung function was measured at the onset of a further 18 episodes of pneumonitis. Measurements made before transplantation showed no difference in forced expiratory volume in one second (FEV1), transfer factor for carbon monoxide (TLCO), or total lung capacity between the two groups, but the forced vital capacity (FVC) was slightly higher in those who developed pneumonitis (mean (SD)% predicted 104 (12)) than in those who did not (93 (17%)). Six weeks and three months after transplantation all pulmonary function measurements had fallen slightly in both groups but TLCO had fallen considerably more in those who later developed pneumonitis, being 71% (SD 11%) and 77% (7%) of pretransplant values in patients who later developed pneumonitis compared with 109% (38%) and 96% (26%) in those who did not. All lung function measurements were significantly lower at the onset of pneumonitis than three months after transplantation, even in patients with no abnormal signs and a normal chest radiograph. Serial measurements of gas transfer before and after bone marrow transplantation may be useful for predicting which patients will be at risk of developing pneumonitis and may help to diagnose pneumonitis in breathless patients with no abnormal signs.
Pulmonary function in children with development coordination disorder.
Wu, Sheng K; Cairney, John; Lin, Hsiao-Hui; Li, Yao-Chuen; Song, Tai-Fen
2011-01-01
The purpose of this study was to compare pulmonary function in children with developmental coordination disorder (DCD) with children who are typically developing (TD), and also analyze possible gender differences in pulmonary function between these groups. The Movement ABC test was used to identify the movement coordination ability of children. Two hundred and fifty participants (90 children with DCD and 160 TD children) aged 9-10 years old completed this study. Using the KoKo spirometry, forced vital capacity (FVC) and forced expiratory volume in 1s (FEV(1.0)) were used to measure pulmonary function. The 800-m run was also conducted to assess cardiopulmonary fitness of children in the field. There was a significant difference in pulmonary function between TD children and those with DCD. The values of FVC and FEV(1.0) in TD children were significantly higher than in children with DCD. A significant, but low correlation (r = -0.220, p < .001) was found between total score on the MABC and FVC; similarly, a positive but low correlation (r = 0.252, p < .001) was found between total score on the MABC and the completion time of 800-m run. However, no significant correlation between FVC and the time of 800-m run was found (p > .05). Significant correlations between total score on the MABC and the completion time of the 800-m run (r = 0.352, p < .05) and between FVC and the time of 800-m run (r = -0.285, p < .05) were observed in girls with DCD but not boys with this condition. Based on the results of this study, pulmonary function in children with DCD was significantly lower than that of TD children. The field test, 800-m run, may not be a good indicator to distinguish aerobic ability between children with DCD and those who are TD. It is possible that poor pulmonary function in children with DCD is due to reduced physical activity in this population. Copyright © 2010 Elsevier Ltd. All rights reserved.
Zhang, D; Guan, Y; Fan, L; Xia, Y; Liu, S Y
2018-05-22
Objective: To quantify emphysema and air trapping at inspiratory and expiratory phase multi-slice spiral CT(MSCT) scanning in smokers without respiratory symptoms, and analyze the correlation between the CT quantifiable parameters and lung function parameters. Methods: A total of 72 smokers, who underwent medical examinations from September 2013 to September 2016 in Changzheng Hospital were enrolled in this research and were divided into two groups: 24 smokers with COPD and 48 smokers without COPD.Besides, thirty-nine non-smokers with normal pulmonary function were enrolled as the controls.All subjects underwent double phase MSCT scanning and pulmonary function tests.CT quantifiable parameters of emphysema included the low attenuation area below a threshold of -950 Hounsfield Units (HU)(LAA%(-950)), the lowest 15th percentile of the histogram of end-inspiratory attenuation values (P(15-IN)), the lowest 15th percentile of the histogram of end-expiratory attenuation values (P(15-EX)), relative volume change(RVC) and the expiratory to inspiratory ratio of mean lung density (E/I(MLD)). Pulmonary function parameters included forced expiratory volume in 1 second expressed as percent predicted (FEV(1)%), forced expiratory volume in one second to forced vital capacity ratio (FEV(1)/FVC), residual volume to total lung capacity ratio (RV/TLC) and carbon monoxide diffusion capacity corrected for alveolar volume (DLCO/VA). The differences of CT quantifiable parameters and pulmonary function parameters among the three groups were analyzed by using one-way analysis of variance or Kruskal - Wallis H test.The correlation between CT quantifiable parameters and pulmonary function parameters was analyzed by using Spearman ' s correlation analysis. Results: The differences of LAA%(-950)(the values for the controls, the group of smokers with out COPD and the group of smokers with COPD were 0.5%±0.7%, 0.7%±1.2% and 2.0%±2.4% respectively), P(15-IN)(the values of the three groups were (-892±33), (-905±15) and (-907±22) HU respectively), FEV(1)%(the values of the three groups were 88.4%±8.8%, 84.2%±7.5% and 82.1%±8.0% respectively), FEV(1)/FVC(the values of the three groups were 78.0%±3.8%, 76.6%±4.3% and 67.3%±5.5% respectively), DLCO/VA (the values of the three groups were (1.36±0.25), (1.30±0.22) and (1.21±0.22) mmol·min(-1)·kPa(-1)·L(-1) respectively) and RV/TLC (the values of the three groups were 49.5%±6.6%, 45.9%±6.0% and 53.0%±6.4% respectively) among the three groups were statistically significant (all P <0.05). In the control group, LAA%(-950) negatively correlated with FEV(1)/FVC and DLCO/VA( r =-0.32, P =0.04; r =-0.69, P =0.00) and neither did P(15-IN) with FEV(1)%( r =-0.14, P =0.02). Inversely, P(15-IN) positively correlated with DLCO/VA ( r =0.55, P =0.00). In the group of smokers without COPD, LAA%(-950) negatively correlated with FEV(1)/FVC and DLCO/VA( r =-0.31, P =0.04; r =-0.42, P =0.00), and P(15-IN) positively correlated with FEV(1)/FVC and DLCO/VA ( r =0.33, P =0.02; r =0.30, P =0.04). In the group of smokers with COPD, LAA%(-950) negatively correlated with DLCO/VA ( r =-0.62, P =0.00), but positively correlated with RV/TLC ( r =0.59, P =0.00). And P(15-IN) positively correlated with DLCO/VA( r =0.53, P =0.01). Conclusions: Smokers emphysema and air trapping can be effectively evaluated by double phase MSCT. Moreover, two of the CT quantifiable parameters, LAA%(-950) and P(15-IN), are highly sensitive to changes in pulmonary function.
NASA Astrophysics Data System (ADS)
Tajik, Jehangir K.; Kugelmass, Steven D.; Hoffman, Eric A.
1993-07-01
We have developed a method utilizing x-ray CT for relating pulmonary perfusion to global and regional anatomy, allowing for detailed study of structure to function relationships. A thick slice, high temporal resolution mode is used to follow a bolus contrast agent for blood flow evaluation and is fused with a high spatial resolution, thin slice mode to obtain structure- function detail. To aid analysis of blood flow, we have developed a software module, for our image analysis package (VIDA), to produce the combined structure-function image. Color coded images representing blood flow, mean transit time, regional tissue content, regional blood volume, regional air content, etc. are generated and imbedded in the high resolution volume image. A text file containing these values along with a voxel's 3-D coordinates is also generated. User input can be minimized to identifying the location of the pulmonary artery from which the input function to a blood flow model is derived. Any flow model utilizing one input and one output function can be easily added to a user selectable list. We present examples from our physiologic based research findings to demonstrate the strengths of combining dynamic CT and HRCT relative to other scanning modalities to uniquely characterize pulmonary normal and pathophysiology.
NASA Technical Reports Server (NTRS)
Pu, M.; Griffin, B. P.; Vandervoort, P. M.; Stewart, W. J.; Fan, X.; Cosgrove, D. M.; Thomas, J. D.
1999-01-01
Although alteration in pulmonary venous flow has been reported to relate to mitral regurgitant severity, it is also known to vary with left ventricular (LV) systolic and diastolic dysfunction. There are few data relating pulmonary venous flow to quantitative indexes of mitral regurgitation (MR). The object of this study was to assess quantitatively the accuracy of pulmonary venous flow for predicting MR severity by using transesophageal echocardiographic measurement in patients with variable LV dysfunction. This study consisted of 73 patients undergoing heart surgery with mild to severe MR. Regurgitant orifice area (ROA), regurgitant stroke volume (RSV), and regurgitant fraction (RF) were obtained by quantitative transesophageal echocardiography and proximal isovelocity surface area. Both left and right upper pulmonary venous flow velocities were recorded and their patterns classified by the ratio of systolic to diastolic velocity: normal (>/=1), blunted (<1), and systolic reversal (<0). Twenty-three percent of patients had discordant patterns between the left and right veins. When the most abnormal patterns either in the left or right vein were used for analysis, the ratio of peak systolic to diastolic flow velocity was negatively correlated with ROA (r = -0.74, P <.001), RSV (r = -0.70, P <.001), and RF (r = -0.66, P <.001) calculated by the Doppler thermodilution method; values were r = -0.70, r = -0.67, and r = -0.57, respectively (all P <.001), for indexes calculated by the proximal isovelocity surface area method. The sensitivity, specificity, and predictive values of the reversed pulmonary venous flow pattern for detecting a large ROA (>0.3 cm(2)) were 69%, 98%, and 97%, respectively. The sensitivity, specificity, and predictive values of the normal pulmonary venous flow pattern for detecting a small ROA (<0.3 cm(2)) were 60%, 96%, and 94%, respectively. However, the blunted pattern had low sensitivity (22%), specificity (61%), and predictive values (30%) for detecting ROA of greater than 0.3 cm(2) with significant overlap with the reversed and normal patterns. Among patients with the blunted pattern, the correlation between the systolic to diastolic velocity ratio was worse in those with LV dysfunction (ejection fraction <50%, r = 0.23, P >.05) than in those with normal LV function (r = -0.57, P <.05). Stepwise linear regression analysis showed that the peak systolic to diastolic velocity ratio was independently correlated with RF (P <.001) and effective stroke volume (P <.01), with a multiple correlation coefficient of 0.71 (P <.001). In conclusion, reversed pulmonary venous flow in systole is a highly specific and reliable marker of moderately severe or severe MR with an ROA greater than 0.3 cm(2), whereas the normal pattern accurately predicts mild to moderate MR. Blunted pulmonary venous flow can be seen in all grades of MR with low predictive value for severity of MR, especially in the presence of LV dysfunction. The blunted pulmonary venous flow pattern must therefore be interpreted cautiously in clinical practice as a marker for severity of MR.
Pulmonary Function, Muscle Strength, and Incident Mobility Disability in Elders
Buchman, Aron S.; Boyle, Patricia A.; Leurgans, Sue E.; Evans, Denis A.; Bennett, David A.
2009-01-01
Muscle strength, including leg strength and respiratory muscle strength, are relatively independently associated with mobility disability in elders. However, the factors linking muscle strength with mobility disability are unknown. To test the hypothesis that pulmonary function mediates the association of muscle strength with the development of mobility disability in elders, we used data from a longitudinal cohort study of 844 ambulatory elders without dementia participating in the Rush Memory and Aging Project with a mean follow-up of 4.0 years (SD = 1.39). A composite measure of pulmonary function was based on spirometric measures of forced vital capacity, forced expiratory volume, and peak expiratory flow. Respiratory muscle strength was based on maximal inspiratory pressure and expiratory pressure and leg strength based on hand-held dynamometry. Mobility disability was defined as a gait speed less than or equal to 0.55 m/s based on annual assessment of timed walk. Secondary analyses considered time to loss of the ability to ambulate. In separate proportional hazards models which controlled for age, sex, and education, composite measures of pulmonary function, respiratory muscle strength, and leg strength were each associated with incident mobility disability (all P values < 0.001). Further, all three were related to the development of incident mobility disability when considered together in a single model (pulmonary function: hazard ratio [HR], 0.721; 95% confidence interval [CI], 0.577, 0.902; respiratory muscle strength: HR, 0.732; 95% CI, 0.593, 0.905; leg strength: HR, 0.791; 95% CI, 0.640, 0.976). Secondary analyses examining incident loss of the ability to ambulate revealed similar findings. Overall, these findings suggest that lower levels of pulmonary function and muscle strength are relatively independently associated with the development of mobility disability in the elderly. PMID:19934353
Koo, Hyeon-Kyoung; Park, Joo-Hyun; Park, Hye Kyeong; Jung, Hoon; Lee, Sung-Soon
2014-01-01
Objective To determine the impact of sarcopenia and obesity on pulmonary function and quality of life (QOL) in chronic obstructive pulmonary disease (COPD) patients. Research Design and Methods Data were obtained from the Korea National Health and Nutrition Examination Survey, including data from health interviews, health examinations, nutritional questionnaires, and laboratory findings. Laboratory data included pulmonary function assessment and dual energy X-ray absorptiometry results. Sarcopenia was measured by dual energy X-ray absorptiometry, and obesity was defined by body mass index. Male COPD patients were then classified into 4 groups according to the presence of sarcopenia and obesity. Results In male patients with COPD, the prevalence of sarcopenia was found to be 29.3%, and that of sarcopenic obesity was 14.2%. Furthermore, 22.5% of the patients observed in this study had impaired QOL. Following multivariable statistical analysis, both sarcopenia and obesity were independent risk factors for worsening lung function. Adjusted values of forced vital capacity and forced expiratory volume in 1 second were the lowest in the sarcopenic obesity group. Sarcopenia was also associated with more subjective activity limitation and poorer QOL; however obesity was related to less subjective limitation and better QOL after multivariable analysis. Adjusted value of QOL was the lowest in sarcopenic subjects without obesity, and the highest in obese subject without sarcopenia. Conclusions Both sarcopenia and obesity were found to be associated with worsening lung function in male COPD patients. However, obesity was positively correlated with improved QOL while sarcopenia was negatively correlated with QQL. PMID:25353344
Tanaka, Rie; Sanada, Shigeru; Okazaki, Nobuo; Kobayashi, Takeshi; Fujimura, Masaki; Yasui, Masahide; Matsui, Takeshi; Nakayama, Kazuya; Nanbu, Yuko; Matsui, Osamu
2006-10-01
Dynamic flat panel detectors (FPD) permit acquisition of distortion-free radiographs with a large field of view and high image quality. The present study was performed to evaluate pulmonary function using breathing chest radiography with a dynamic FPD. We report primary results of a clinical study and computer algorithm for quantifying and visualizing relative local pulmonary airflow. Dynamic chest radiographs of 18 subjects (1 emphysema, 2 asthma, 4 interstitial pneumonia, 1 pulmonary nodule, and 10 normal controls) were obtained during respiration using an FPD system. We measured respiratory changes in distance from the lung apex to the diaphragm (DLD) and pixel values in each lung area. Subsequently, the interframe differences (D-frame) and difference values between maximum inspiratory and expiratory phases (D-max) were calculated. D-max in each lung represents relative vital capacity (VC) and regional D-frames represent pulmonary airflow in each local area. D-frames were superimposed on dynamic chest radiographs in the form of color display (fusion images). The results obtained using our methods were compared with findings on computed tomography (CT) images and pulmonary functional test (PFT), which were examined before inclusion in the study. In normal subjects, the D-frames were distributed symmetrically in both lungs throughout all respiratory phases. However, subjects with pulmonary diseases showed D-frame distribution patterns that differed from the normal pattern. In subjects with air trapping, there were some areas with D-frames near zero indicated as colorless areas on fusion images. These areas also corresponded to the areas showing air trapping on computed tomography images. In asthma, obstructive abnormality was indicated by areas continuously showing D-frame near zero in the upper lung. Patients with interstitial pneumonia commonly showed fusion images with an uneven color distribution accompanied by increased D-frames in the area identified as normal on computed tomography images. Furthermore, measurement of DLD was very effective for evaluating diaphragmatic kinetics. This is a rapid and simple method for evaluation of respiratory kinetics for pulmonary diseases, which can reveal abnormalities in diaphragmatic kinetics and regional lung ventilation. Furthermore, quantification and visualization of respiratory kinetics is useful as an aid in interpreting dynamic chest radiographs.
Influence of pulmonary emphysema on COPD assessment test-oriented categorization in GOLD document.
Suzuki, Toshio; Tada, Yuji; Kawata, Naoko; Ikari, Jun; Kasahara, Yasunori; Sakurai, Yoriko; Iesato, Ken; Nishimura, Rintaro; West, James; Tatsumi, Koichiro
2015-01-01
The COPD assessment test (CAT) score is a key component of the multifactorial assessment of COPD in the Global initiative for chronic Obstructive Lung Disease (GOLD) guidelines of 2014. Nevertheless, little is known regarding the differences among COPD categories in terms of clinical parameters such as pulmonary function or radiological findings. Thus, our aims in this study were to evaluate the associations between CAT scores and pulmonary clinical parameters, and to investigate factors that could discriminate between a "less symptomatic group" (categories A and C) and a "more symptomatic group" (categories B and D) among stable COPD patients. We enrolled 200 outpatients at Chiba University Hospital. Study subjects were assessed by CAT, pulmonary function testing, and multidetector computed tomography (MDCT). We assessed possible correlations between these indices. CAT scores were negatively correlated with percentage of the forced expiratory volume in 1 second predicted value (FEV1 %predicted) and percentage of the diffusing capacity for carbon monoxide per liter of lung volume predicted value (DLCO/VA [%predicted]) results and positively correlated with low attenuation volume percentage (LAV%) and residual volume to total lung capacity ratios (RV/TLC). In the "more symptomatic group" (category B or D), the mean DLCO/VA (%predicted) was significantly lower and the mean LAV% and RV/TLC was significantly higher than those in the "less symptomatic group" (category A or C), respectively. Interestingly, those in category B had higher mean LAV% compared to those in category C. CAT scores were significantly correlated with pulmonary function parameters and emphysematous changes on MDCT. The new GOLD classification system would be a step toward a phenotypic approach, especially taking into account the degree of emphysema and hyperinflation.
Abnormal pulmonary function in adults with sickle cell anemia.
Klings, Elizabeth S; Wyszynski, Diego F; Nolan, Vikki G; Steinberg, Martin H
2006-06-01
Pulmonary complications of sickle cell anemia (Hb-SS) commonly cause morbidity, yet few large studies of pulmonary function tests (PFTs) in this population have been reported. PFTs (spirometry, lung volumes, and diffusion capacity for carbon monoxide [DLCO]) from 310 adults with Hb-SS were analyzed to determine the pattern of pulmonary dysfunction and their association with other systemic complications of sickle cell disease. Raw PFT data were compared with predicted values. Each subject was subclassified into one of five groups: obstructive physiology, restrictive physiology, mixed obstructive/restrictive physiology, isolated low DLCO, or normal. The association between laboratory data of patients with decreased DLCO or restrictive physiology and those of normal subjects was assessed by multivariate linear regression. Normal PFTs were present in only 31 of 310 (10%) patients. Overall, adults with Hb-SS were characterized by decreased total lung capacities (70.2 +/- 14.7% predicted) and DLCO (64.5 +/- 19.9%). The most common PFT patterns were restrictive physiology (74%) and isolated low DLCO (13%). Decreased DLCO was associated with thrombocytosis (p = 0.05), with hepatic dysfunction (elevated alanine aminotransferase; p = 0.07), and a trend toward renal dysfunction (elevated blood urea nitrogen and creatinine; p = 0.05 and 0.07, respectively). Pulmonary function is abnormal in 90% of adult patients with Hb-SS. Common abnormalities include restrictive physiology and decreased DLCO. Decreased DLCO may indicate more severe sickle vasculopathy characterized by impaired hepatic and renal function.
Swift, Andrew J; Rajaram, Smitha; Condliffe, Robin; Capener, Dave; Hurdman, Judith; Elliot, Charlie; Kiely, David G; Wild, Jim M
2012-10-01
The aim of this study was to evaluate the clinical use of magnetic resonance imaging measurements related to pulmonary artery stiffness in the evaluation of pulmonary hypertension (PH). A total of 134 patients with suspected PH underwent right heart catheterization (RHC) and magnetic resonance imaging on a 1.5-T scanner within 2 days. Phase contrast imaging at the pulmonary artery trunk and cine cardiac views were acquired. Pulmonary artery area change (AC), relative AC (RAC), compliance (AC/pulse pressure from RHC), distensibility (RAC/pulse pressure from RHC), right ventricular functional indices, and right ventricular mass were all derived. Regression curve fitting identified the statistical model of best fit between RHC measurements and pulmonary artery stiffness indices. The diagnostic accuracy and prognostic value of noninvasive AC and RAC were also assessed. The relationship between pulmonary vascular resistance and pulmonary artery RAC was best reflected by an inverse linear model. Patients with mild elevation in pulmonary vascular resistance (<4 Woods units) demonstrated reduced RAC (P = 0.02) and increased right ventricular mass index (P < 0.0001) without significant loss of right ventricular function (P = 0.17). At follow-up of 0 to 40 months, 18 patients with PH had died (16%). Analysis of Kaplan-Meier plots showed that both AC and RAC predicted mortality (log-rank test, P = 0.046 and P = 0.012, respectively). Area change and RAC were also predictors of mortality using univariate Cox proportional hazards regression analysis (P = 0.046 and P = 0.03, respectively). Noninvasive assessment of pulmonary artery RAC is a marker sensitive to early increased vascular resistance in PH and is a predictor of adverse outcome.
Jung, Jae-Woo; Choi, Jae-Chol; Shin, Jong-Wook; Kim, Jae-Yeol; Choi, Byoung-Whui; Park, In-Won
2015-01-01
Pulmonary tuberculosis (TB) can affect lung function, but studies regarding long-term follow-up in patients with no sequelae on chest X-ray (CXR) have not been performed. We evaluated lung functional impairment and persistent respiratory symptoms in those with prior pulmonary TB and those with prior pulmonary TB with no residual sequelae on CXR, and determined risk factors for airflow obstruction. We used data from adults aged ≥ 40 years from the annual Korean National Health and Nutrition Examination Surveys conducted between 2008 and 2012. P values for comparisons were adjusted for age, sex, and smoking status. In total of 14,967 adults, 822 subjects (5.5%) had diagnosed and treated pulmonary TB (mean 29.0 years ago). The FVC% (84.9 vs. 92.6), FEV1% (83.4 vs. 92.4), and FEV1/FVC% (73.4 vs. 77.9) were significantly decreased in subjects with prior pulmonary TB compared to those without (p < 0.001, each). In 12,885 subjects with no sequalae on CXR, those with prior pulmonary TB (296, 2.3%) had significantly lower FEV1% (90.9 vs. 93.4, p = 0.001) and FEV1/FVC% (76.6 vs. 78.4, p < 0.001) than those without. Subjects with prior pulmonary TB as well as subjects with no sequalae on CXR were more likely to experience cough and physical activity limitations due to pulmonary symptoms than those without prior pulmonary TB (p < 0.001, each). In total subjects, prior pulmonary TB (OR, 2.314; 95% CI, 1.922-2.785), along with age, male, asthma, and smoking mount was risk factor for airflow obstruction. In subjects with prior pulmonary tuberculosis, inactive TB lesion on chest x-ray (OR, 2.300; 95% CI, 1.606-3.294) were risk factors of airflow obstruction. In addition to subjects with inactive TB lesion on CXR, subjects with no sequelae on CXR can show impaired pulmonary function and respiratory symptoms. Prior TB is a risk factor for airflow obstruction and that the risk is more important when they have inactive lesions on chest X-ray. Hence, the patients with treated TB should need to have regular follow-up of lung function and stop smoking for early detection and prevention of the chronic airway disease.
Lung function in retired coke oven plant workers.
Chau, N; Bertrand, J P; Guenzi, M; Mayer, L; Téculescu, D; Mur, J M; Patris, A; Moulin, J J; Pham, Q T
1992-01-01
Lung function was studied in 354 coke oven plant workers in the Lorraine collieries (Houillères du Bassin de Lorraine, France) who retired between 1963 and 1982 and were still alive on 1 January 1988. A spirometric examination was performed on 68.4% of them in the occupational health service. Occupational exposure to respiratory hazards throughout their career was retraced for each subject. No adverse effect of occupational exposure on ventilatory function was found. Ventilatory function was, however negatively linked with smoking and with the presence of a respiratory symptom or discrete abnormalities visible on pulmonary x ray films. The functional values were mostly slightly lower than predicted values and the most reduced index was the mean expiratory flow, FEF25-75%. The decrease in forced expiratory volume in one second (FEV1) was often parallel to that in forced vital capacity (FVC), but it was more pronounced for subjects who had worked underground, for smokers of more than 30 pack-years, and for subjects having a respiratory symptom. Pulmonary function indices were probably overestimated because of the exclusion of deceased subjects and the bias of the participants. PMID:1599869
In Vitro Study of Flow Regulation for Pulmonary Insufficiency
Camp, T. A.; Stewart, K. C.; Figliola, R. S.; McQuinn, T.
2007-01-01
Given the tolerance of the right heart circulation to mild regurgitation and gradient, we study the potential of using motionless devices to regulate the pulmonary circulation. In addition, we document the flow performance of two mechanical valves. A motionless diode, a nozzle, a mechanical bileaflet valve, and a tilting disk valve were tested in a pulmonary mock circulatory system over the normal human range of pulmonary vascular resistance (PVR). For the mechanical valves, regurgitant fractions (RFs) and transvalvular pressure gradients were found to be weak functions of PVR. On the low end of normal PVR, the bileaflet and tilting disk valves fluttered and would not fully close. Despite this anomaly, the regurgitant fraction of either valve did not change significantly. The values for RF and transvalvular gradient measured varied from 4 to 7% and 4 to 7 mm Hg, respectively, at 5 lpm for all tests. The diode valve was able to regulate flow with mild regurgitant fraction and trivial gradient but with values higher than either mechanical valve tested. Regurgitant fraction ranged from 2 to 17% in tests extending from PVR values of 1 to 4.5 mm Hg/lpm at 5 lpm and with concomitant increases in gradient up to 17 mm Hg. The regurgitant fraction for the nozzle increased from 2 to 23% over the range of PVR with gradients increasing to 18 mm Hg. The significant findings were: (1) the mechanical valves controlled regurgitation at normal physiological cardiac output and PVR even though they failed to close at some normal values of PVR and showed leaflet flutter; and (2) it may be possible to regulate the pulmonary circulation to tolerable levels using a motionless pulmonary valve device. PMID:17408334
Smargiassi, Andrea; Inchingolo, Riccardo; Tagliaboschi, Linda; Di Marco Berardino, Alessandro; Valente, Salvatore; Corbo, Giuseppe Maria
2014-01-01
Skeletal muscle weakness with loss of fat-free mass (FFM) is one of the main systemic effects of chronic obstructive pulmonary disease (COPD). The diaphragm is also involved, leading to disadvantageous conditions and poor contractile capacities. We measured the thickness of the diaphragm (TD) by ultrasonography to evaluate the relationships between echographic measurements, parameters of respiratory function and body composition data. Thirty-two patients (23 males) underwent (1) pulmonary function tests, (2) echographic assessment of TD in the zone of apposition at various lung volumes, i.e. TD at residual volume (TDRV), TD at functional residual capacity (TDFRC) and TD at total lung capacity (TDTLC), and (3) bioelectrical body impedance analysis. The BMI and the BODE (BMI-Obstruction-Dyspnea-Exercise) index values were reported. TDRV, TDFRC and TDTLC measured 3.3, 3.6 and 6 mm, respectively, with good intraobserver reproducibility (0.97, 0.97 and 0.96, respectively). All the TDs were found to be related to FFM, with the relationship being greater for TDFRC (r(2) = 0.39 and p = 0.0002). With regard to lung volumes, inspiratory capacity (IC) was found to be closely related to TDTLC (r(2) = 0.42 and p = 0.0001). The difference between TDTLC and TDRV, as a thickening value (TDTLCRV), was closely related to FVC (r(2) = 0.34 and p = 0.0004) and to air-trapping indices (RV/TLC, FRC/TLC and IC/TLC): the degree of lung hyperinflation was greater and the TDTLCRV was less. Finally, we found a progressive reduction of both thicknesses and thickenings as the severity of IC/TLC increased, with a significant p value for the trend in both analyses (p = 0.02). Ultrasonographic assessment of the diaphragm could be a useful tool for studying disease progression in COPD patients, in terms of lung hyperinflation and the loss of FFM. © 2014 S. Karger AG, Basel.
Shieh, Tzong-Shiun; Chung, Jui-Jung; Wang, Chung-Jing; Tsai, Perng-Jy; Kuo, Yau-Chang; Guo, How-Ran
2012-02-13
To evaluate pulmonary function and respiratory symptoms in workers engaged in the early manufacturing processes of tea and to identify the associated factors, we conducted a study in a tea production area in Taiwan. We recruited tea workers who engaged in the early manufacturing process in the Mountain Ali area in Taiwan and a comparison group of local office workers who were matched for age, gender, and smoking habits. We performed questionnaire interviews, pulmonary function tests, skin prick tests, and measurement of specific IgE for tea on the participants and assessed tea dust exposures in the tea factories. The 91 participating tea workers had higher prevalence of respiratory symptoms than the comparison group (32 participants). Among tea workers, ball-rolling workers had the highest prevalence of symptoms and the highest exposures of inhalable dusts. At baseline, tea workers had similar pulmonary functions as the comparison group, but compared to the other tea workers ball-rolling workers had a lower ratio of the 1-second forced expiratory volume to forced vital capacity (FEV1/FVC) and a lower maximal mid-expiratory flow rate expressed as% of the predicted value--MMF (%pred). A total of 58 tea workers participated in the on-site investigation and the cross-shift lung function measurements. We found ball-rolling yielded the highest inhalable dust level, panning yielded the highest respirable dust level, and withering yielded the lowest levels of both dusts. Ball-rolling also yielded the highest coarse fraction (defined as inhalable dusts minus respirable dusts), which represented exposures from nose to tracheobronchial tract. During the shift, we observed significant declines in pulmonary function, especially in ball-rolling workers. Multiple regressions showed that age, height, work tasks, coarse fraction, and number of months working in tea manufacturing each year were independent predictors of certain pulmonary function parameters in tea workers. Tea workers engaged in early manufacturing processes of tea have higher prevalence of respiratory symptoms and pulmonary function impairment, which might be related to tea dust exposures, especially the coarse fraction.
A Non-Invasive Assessment of Cardiopulmonary Hemodynamics with MRI in Pulmonary Hypertension
Bane, Octavia; Shah, Sanjiv J.; Cuttica, Michael J.; Collins, Jeremy D.; Selvaraj, Senthil; Chatterjee, Neil R.; Guetter, Christoph; Carr, James C.; Carroll, Timothy J.
2015-01-01
Purpose We propose a method for non-invasive quantification of hemodynamic changes in the pulmonary arteries resulting from pulmonary hypertension (PH). Methods Using a two-element windkessel model, and input parameters derived from standard MRI evaluation of flow, cardiac function and valvular motion, we derive: pulmonary artery compliance (C), mean pulmonary artery pressure (mPAP), pulmonary vascular resistance (PVR), pulmonary capillary wedge pressure (PCWP), time-averaged intra-pulmonary pressure waveforms and pulmonary artery pressures (systolic (sPAP) and diastolic (dPAP)). MRI results were compared directly to reference standard values from right heart catheterization (RHC) obtained in a series of patients with suspected pulmonary hypertension (PH). Results In 7 patients with suspected PH undergoing RHC, MRI and echocardiography, there was no statistically significant difference (p<0.05) between parameters measured by MRI and RHC. Using standard clinical cutoffs to define PH (mPAP ≥ 25 mmHg), MRI was able to correctly identify all patients as having pulmonary hypertension, and to correctly distinguish between pulmonary arterial (mPAP≥ 25 mmHg, PCWP<15 mmHg) and venous hypertension (mPAP ≥ 25 mmHg, PCWP ≥ 15 mmHg) in 5 of 7 cases. Conclusions We have developed a mathematical model capable of quantifying physiological parameters that reflect the severity of PH. PMID:26283577
Krause, Kathrin; Kopp, Benjamin T; Tazi, Mia F; Caution, Kyle; Hamilton, Kaitlin; Badr, Asmaa; Shrestha, Chandra; Tumin, Dmitry; Hayes, Don; Robledo-Avila, Frank; Hall-Stoodley, Luanne; Klamer, Brett G; Zhang, Xiaoli; Partida-Sanchez, Santiago; Parinandi, Narasimham L; Kirkby, Stephen E; Dakhlallah, Duaa; McCoy, Karen S; Cormet-Boyaka, Estelle; Amer, Amal O
2018-07-01
Cystic fibrosis (CF) is a multi-organ disorder characterized by chronic sino-pulmonary infections and inflammation. Many patients with CF suffer from repeated pulmonary exacerbations that are predictors of worsened long-term morbidity and mortality. There are no reliable markers that associate with the onset or progression of an exacerbation or pulmonary deterioration. Previously, we found that the Mirc1/Mir17-92a cluster which is comprised of 6 microRNAs (Mirs) is highly expressed in CF mice and negatively regulates autophagy which in turn improves CF transmembrane conductance regulator (CFTR) function. Therefore, here we sought to examine the expression of individual Mirs within the Mirc1/Mir17-92 cluster in human cells and biological fluids and determine their role as biomarkers of pulmonary exacerbations and response to treatment. Mirc1/Mir17-92 cluster expression was measured in human CF and non-CF plasma, blood-derived neutrophils, and sputum samples. Values were correlated with pulmonary function, exacerbations and use of CFTR modulators. Mirc1/Mir17-92 cluster expression was not significantly elevated in CF neutrophils nor plasma when compared to the non-CF cohort. Cluster expression in CF sputum was significantly higher than its expression in plasma. Elevated CF sputum Mirc1/Mir17-92 cluster expression positively correlated with pulmonary exacerbations and negatively correlated with lung function. Patients with CF undergoing treatment with the CFTR modulator Ivacaftor/Lumacaftor did not demonstrate significant change in the expression Mirc1/Mir17-92 cluster after six months of treatment. Mirc1/Mir17-92 cluster expression is a promising biomarker of respiratory status in patients with CF including pulmonary exacerbation. Published by Elsevier B.V.
Measurement of cardiac output from dynamic pulmonary circulation time CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yee, Seonghwan, E-mail: Seonghwan.Yee@Beaumont.edu; Scalzetti, Ernest M.
Purpose: To introduce a method of estimating cardiac output from the dynamic pulmonary circulation time CT that is primarily used to determine the optimal time window of CT pulmonary angiography (CTPA). Methods: Dynamic pulmonary circulation time CT series, acquired for eight patients, were retrospectively analyzed. The dynamic CT series was acquired, prior to the main CTPA, in cine mode (1 frame/s) for a single slice at the level of the main pulmonary artery covering the cross sections of ascending aorta (AA) and descending aorta (DA) during the infusion of iodinated contrast. The time series of contrast changes obtained for DA,more » which is the downstream of AA, was assumed to be related to the time series for AA by the convolution with a delay function. The delay time constant in the delay function, representing the average time interval between the cross sections of AA and DA, was determined by least square error fitting between the convoluted AA time series and the DA time series. The cardiac output was then calculated by dividing the volume of the aortic arch between the cross sections of AA and DA (estimated from the single slice CT image) by the average time interval, and multiplying the result by a correction factor. Results: The mean cardiac output value for the six patients was 5.11 (l/min) (with a standard deviation of 1.57 l/min), which is in good agreement with the literature value; the data for the other two patients were too noisy for processing. Conclusions: The dynamic single-slice pulmonary circulation time CT series also can be used to estimate cardiac output.« less
Scarneciu, Camelia C; Sangeorzan, Livia; Rus, Horatiu; Scarneciu, Vlad D; Varciu, Mihai S; Andreescu, Oana; Scarneciu, Ioan
2017-01-01
This study aimed at assessing the incidence of pulmonary hypertension (PH) at newly diagnosed hyperthyroid patients and at finding a simple model showing the complex functional relation between pulmonary hypertension in hyperthyroidism and the factors causing it. The 53 hyperthyroid patients (H-group) were evaluated mainly by using an echocardiographical method and compared with 35 euthyroid (E-group) and 25 healthy people (C-group). In order to identify the factors causing pulmonary hypertension the statistical method of comparing the values of arithmetical means is used. The functional relation between the two random variables (PAPs and each of the factors determining it within our research study) can be expressed by linear or non-linear function. By applying the linear regression method described by a first-degree equation the line of regression (linear model) has been determined; by applying the non-linear regression method described by a second degree equation, a parabola-type curve of regression (non-linear or polynomial model) has been determined. We made the comparison and the validation of these two models by calculating the determination coefficient (criterion 1), the comparison of residuals (criterion 2), application of AIC criterion (criterion 3) and use of F-test (criterion 4). From the H-group, 47% have pulmonary hypertension completely reversible when obtaining euthyroidism. The factors causing pulmonary hypertension were identified: previously known- level of free thyroxin, pulmonary vascular resistance, cardiac output; new factors identified in this study- pretreatment period, age, systolic blood pressure. According to the four criteria and to the clinical judgment, we consider that the polynomial model (graphically parabola- type) is better than the linear one. The better model showing the functional relation between the pulmonary hypertension in hyperthyroidism and the factors identified in this study is given by a polynomial equation of second degree where the parabola is its graphical representation.
Cardiopulmonary Exercise Testing in Patients Following Massive and Submassive Pulmonary Embolism.
Albaghdadi, Mazen S; Dudzinski, David M; Giordano, Nicholas; Kabrhel, Christopher; Ghoshhajra, Brian; Jaff, Michael R; Weinberg, Ido; Baggish, Aaron
2018-03-03
Little data exist regarding the functional capacity of patients following acute pulmonary embolism. We sought to characterize the natural history of symptom burden, right ventricular (RV) structure and function, and exercise capacity among survivors of massive and submassive pulmonary embolism. Survivors of submassive or massive pulmonary embolism (n=20, age 57±13.3 years, 8/20 female) underwent clinical evaluation, transthoracic echocardiography, and cardiopulmonary exercise testing at 1 and 6 months following hospital discharge. At 1 month, 9/20 (45%) patients had New York Heart Association II or greater symptoms, 13/20 (65%) demonstrated either persistent RV dilation or systolic dysfunction, and 14/20 (70%) had objective exercise impairment as defined by a peak oxygen consumption (V˙O 2 ) of <80% of age-sex predicted maximal values (16.25 [13.4-20.98] mL/kg per minute). At 6 months, no appreciable improvements in symptom severity, RV structure or function, and peak V˙O 2 (17.45 [14.08-22.48] mL/kg per minute, P =NS) were observed. No patients demonstrated an exercise limitation attributable to either RV/pulmonary vascular coupling, as defined by a VE/VCO 2 slope >33, or a pulmonary mechanical limit to exercise at either time point. Similarly, persistent RV dilation or dysfunction was not significantly related to symptom burden or peak V˙O 2 at either time point. Persistent symptoms, abnormalities of RV structure and function, and objective exercise limitation are common among survivors of massive and submassive pulmonary embolism. Functional impairment appears to be attributable to general deconditioning rather than intrinsic cardiopulmonary limitation, suggesting an important role for prescribed exercise rehabilitation as a means toward improved patient outcomes and quality of life. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Joo, Sunghee; Shin, Doochul; Song, Changho
2015-06-22
Reduction of respiratory function along with hemiparesis leads to decreased endurance, dyspnea, and increased sedentary behavior, as well as to an increased risk of stroke. The main purpose of this study was to investigate the preliminary effects of game-based breathing exercise (GBE) on pulmonary function in stroke patients. Thirty-eight in-patients with stroke (22 men, 16 women) were recruited for the study. Participants were randomly allocated into 2 groups: patients assigned to the GBE group (n=19), and the control group (n=19). The GBE group participated in a GBE program for 25 minutes a day, 3 days a week, during a 5 week period. For the same period, both groups participated in a conventional stroke rehabilitation program. Forced vital capacity (FVC), forced expiratory volume at 1 second (FEV1), FEV1/FVC, and maximum voluntary ventilation (MVV) were measured by a spirometer in pre- and post-testing. The GBE group had significantly improved FVC, FEV1, and MVV values compared with the control group (p<0.05), although there was no significant difference in FEV1/FVC value between groups. Significant short-term effects of the GBE program on pulmonary function in stroke patients were recorded in this study. These findings gave some indications that it may be feasible to include GBE in rehabilitation interventions with this population.
Boutou, Afroditi K; Nair, Arjun; Douraghi-Zadeh, Dariush; Sandhu, Ranbir; Hansell, David M; Wells, Athol U; Polkey, Michael I; Hopkinson, Nicholas S
2014-01-01
Chronic Obstructive Pulmonary Disease (COPD) is characterized by high morbidity and mortality. Lung computed tomography parameters, individually or as part of a composite index, may provide more prognostic information than pulmonary function tests alone. To investigate the prognostic value of emphysema score and pulmonary artery measurements compared with lung function parameters in COPD and construct a prognostic index using a contingent staging approach. Predictors of mortality were assessed in COPD outpatients whose lung computed tomography, spirometry, lung volumes and gas transfer data were collected prospectively in a clinical database. Univariate and multivariate Cox proportional hazard analysis models with bootstrap techniques were used. 169 patients were included (59.8% male, 61.1 years old; Forced Expiratory Volume in 1 second % predicted: 40.5±19.2). 20.1% died; mean survival was 115.4 months. Age (HR = 1.098, 95% Cl = 1.04-1.252) and emphysema score (HR = 1.034, 95% CI = 1.007-1.07) were the only independent predictors of mortality. Pulmonary artery dimensions were not associated with survival. An emphysema score of 55% was chosen as the optimal threshold and 30% and 65% as suboptimals. Where emphysema score was between 30% and 65% (intermediate risk) the optimal lung volume threshold, a functional residual capacity of 210% predicted, was applied. This contingent staging approach separated patients with an intermediate risk based on emphysema score alone into high risk (Functional Residual Capacity ≥210% predicted) or low risk (Functional Residual Capacity <210% predicted). This approach was more discriminatory for survival (HR = 3.123; 95% CI = 1.094-10.412) than either individual component alone. Although to an extent limited by the small sample size, this preliminary study indicates that the composite Emphysema score-Functional Residual Capacity index might provide a better separation of high and low risk patients with COPD, than other individual predictors alone.
Non-invasive pulmonary function test on Morquio Patients
Kubaski, Francyne; Tomatsu, Shunji; Patel, Pravin; Shimada, Tsutomu; Xie, Li; Yasuda, Eriko; Mason, Robert; Mackenzie, William G.; Theroux, Mary; Bober, Michael B.; Oldham, Helen M.; Orii, Tadao; Shaffer, Thomas H.
2015-01-01
In clinical practice, respiratory function tests are difficult to perform in Morquio syndrome patients due to their characteristic skeletal dysplasia, small body size and lack of cooperation of young patients, where in some cases, conventional spirometry for pulmonary function is too challenging. To establish feasible clinical pulmonary endpoints and determine whether age impacts lung function in Morquio patients non-invasive pulmonary tests and conventional spirometry were evaluated. The non-invasive pulmonary tests: impulse oscillometry system, pneumotachography, and respiratory inductance plethysmography in conjunction with conventional spirometry were evaluated in twenty-two Morquio patients (18 Morquio A and 4 Morquio B) (7 males), ranging from 3 and 40 years of age. Twenty-two patients were compliant with non-invasive tests (100%) with exception of IOS (81.8%–18 patients). Seventeen patients (77.3%) were compliant with spirometry testing. All subjects had normal vital signs at rest including > 95% oxygen saturation, end tidal CO2 (38–44 mmHg), and age-appropriate heart rate (mean=98.3, standard deviation=19) (two patients were deviated). All patients preserved normal values in impulse oscillometry system, pneumotachography, and respiratory inductance plethysmography, although predicted forced expiratory volume total (72.8 ± 6.9 SE%) decreased with age and was below normal; phase angle (35.5 ± 16.5 Degrees), %Rib Cage (41.6 ± 12.7%), resonant frequency, and forced expiratory volume in one second/forced expiratory volume total (110.0 ± 3.2 SE%) were normal and not significantly impacted by age. The proposed non-invasive pulmonary function tests are able to cover a greater number of patients (young patients and/or wheel-chair bound), thus providing a new diagnostic approach for the assessment of lung function in Morquio syndrome which in many cases may be difficult to evaluate. Morquio patients studied herein demonstrated no clinical or functional signs of restrictive and/or obstructive lung disease. PMID:26116954
Incentive spirometry does not enhance recovery after thoracic surgery.
Gosselink, R; Schrever, K; Cops, P; Witvrouwen, H; De Leyn, P; Troosters, T; Lerut, A; Deneffe, G; Decramer, M
2000-03-01
To investigate the additional effect of incentive spirometry to chest physiotherapy to prevent postoperative pulmonary complications after thoracic surgery for lung and esophageal resections. Randomized controlled trial. University hospital, intensive care unit, and surgical department. Sixty-seven patients (age, 59 +/- 13 yrs; forced expiratory volume in 1 sec, 93% +/- 22% predicted) undergoing elective thoracic surgery for lung (n = 40) or esophagus (n = 27) resection. Physiotherapy (breathing exercises, huffing, and coughing) (PT) plus incentive spirometry (IS) was compared with PT alone. Lung function, body temperature, chest radiograph, white blood cell count, and number of hospital and intensive care unit days were all measured. Pulmonary function was significantly reduced after surgery (55% of the initial value) and improved significantly in the postoperative period in both groups. However, no differences were observed in the recovery of pulmonary function between the groups. The overall score of the chest radiograph, based on the presence of atelectasis, was similar in both treatment groups. Eight patients (12%) (three patients with lobectomy and five with esophagus resection) developed a pulmonary complication (abnormal chest radiograph, elevated body temperature and white blood cell count), four in each treatment group. Adding IS to regular PT did not reduce hospital or intensive care unit stay. Pulmonary complications after lung and esophagus surgery were relatively low. The addition of IS to PT did not further reduce pulmonary complications or hospital stay. Although we cannot rule out beneficial effects in a subgroup of high-risk patients, routine use of IS after thoracic surgery seems to be ineffective.
Pulmonary Vascular Congestion: A Mechanism for Distal Lung Unit Dysfunction in Obesity.
Oppenheimer, Beno W; Berger, Kenneth I; Ali, Saleem; Segal, Leopoldo N; Donnino, Robert; Katz, Stuart; Parikh, Manish; Goldring, Roberta M
2016-01-01
Obesity is characterized by increased systemic and pulmonary blood volumes (pulmonary vascular congestion). Concomitant abnormal alveolar membrane diffusion suggests subclinical interstitial edema. In this setting, functional abnormalities should encompass the entire distal lung including the airways. We hypothesize that in obesity: 1) pulmonary vascular congestion will affect the distal lung unit with concordant alveolar membrane and distal airway abnormalities; and 2) the degree of pulmonary congestion and membrane dysfunction will relate to the cardiac response. 54 non-smoking obese subjects underwent spirometry, impulse oscillometry (IOS), diffusion capacity (DLCO) with partition into membrane diffusion (DM) and capillary blood volume (VC), and cardiac MRI (n = 24). Alveolar-capillary membrane efficiency was assessed by calculation of DM/VC. Mean age was 45±12 years; mean BMI was 44.8±7 kg/m2. Vital capacity was 88±13% predicted with reduction in functional residual capacity (58±12% predicted). Despite normal DLCO (98±18% predicted), VC was elevated (135±31% predicted) while DM averaged 94±22% predicted. DM/VC varied from 0.4 to 1.4 with high values reflecting recruitment of alveolar membrane and low values indicating alveolar membrane dysfunction. The most abnormal IOS (R5 and X5) occurred in subjects with lowest DM/VC (r2 = 0.31, p<0.001; r2 = 0.34, p<0.001). Cardiac output and index (cardiac output / body surface area) were directly related to DM/VC (r2 = 0.41, p<0.001; r2 = 0.19, p = 0.03). Subjects with lower DM/VC demonstrated a cardiac output that remained in the normal range despite presence of obesity. Global dysfunction of the distal lung (alveolar membrane and distal airway) is associated with pulmonary vascular congestion and failure to achieve the high output state of obesity. Pulmonary vascular congestion and consequent fluid transudation and/or alterations in the structure of the alveolar capillary membrane may be considered often unrecognized causes of airway dysfunction in obesity.
Effect of cervical epidural blockade with 2% lidocaine plus epinephrine on respiratory function.
Huang, Chih-Hung
2007-12-01
Cervical epidural anesthesia has been used widely for surgery of upper limbs. Although cervical epidural anesthesia with local anesthetic of 2% lidocaine (plain) has demonstrated the safety in respiratory function in spite of unavoidable phrenic and intercostal palsies to certain extent, the replacement of local anesthetics with 2% lidocaine plus epinephrine has not been investigated yet. I conducted this study to look into the effect of 2% lidocaine plus epinephrine on respiratory function. I collected data from 50 patients with mean age of 24 +/- 3 yrs, mean weight of 65 +/- 10 kg, ASA status: I-II without preoperative pulmonary dysfunction undergoing orthropedic open-reduction with internal fixation because of fractures of upper limbs. Cervical epidural space (C7-T1) was approached by hanging-drop method, using a 17G Tuohy needle. A catheter was inserted craniad to a distance of 12 cm. Pulmonary function measurement and arterial blood gas data were obstained before, 20 min, 50 min and 105 min after injection of 12 mL 2% lidocaine with 1:200,000 epinephrine. The anesthesia levels were between C3-T3 and obtained 15 +/- 2 min after injection. Mean arterial blood gas analysis showed mild respiratory acidosis at 20 min (PaCO2: 48 +/- 3 mmHg) and 50 min (PaCO2: 44 +/- 2 mmHg). The measured values of inspiratory vital capacity (IVC), vital capacity (VC), forced vital capacity (FVC), forced expiratory volume in 1 sec (FEV1), peak expiratory flow (PEF) when compaired with control values, were decreased about 18.0% and 12.1% of the control values at 20 min and 50 min respectively. The ratios of FEV1/VC, FEV1/FVC were still within normal limits (> 80%). The results were significantly compatible with the criteria of mild restrictive type of pulmonary function. Cervical epidural anesthesia with 2% lidocaine plus epinephrine could reduce lung volumes and capacities, resulting from partially paralytic intercostal muscles and diaphragm innervated respectively by thoracic intercostal nerve and phrenic nerve. Without inadvertant total spinal or intravenous anesthesia or pre-existing pulmonary dysfunction, the patients with normal lungs could tolerate these changes well with the procedure.
Abnormal Pulmonary Function in Adults with Sickle Cell Anemia
Klings, Elizabeth S.; Wyszynski, Diego F.; Nolan, Vikki G.; Steinberg, Martin H.
2006-01-01
Rationale: Pulmonary complications of sickle cell anemia (Hb-SS) commonly cause morbidity, yet few large studies of pulmonary function tests (PFTs) in this population have been reported. Objectives: PFTs (spirometry, lung volumes, and diffusion capacity for carbon monoxide [DLCO]) from 310 adults with Hb-SS were analyzed to determine the pattern of pulmonary dysfunction and their association with other systemic complications of sickle cell disease. Methods: Raw PFT data were compared with predicted values. Each subject was subclassified into one of five groups: obstructive physiology, restrictive physiology, mixed obstructive/restrictive physiology, isolated low DLCO, or normal. The association between laboratory data of patients with decreased DLCO or restrictive physiology and those of normal subjects was assessed by multivariate linear regression. Measurements and Main Results: Normal PFTs were present in only 31 of 310 (10%) patients. Overall, adults with Hb-SS were characterized by decreased total lung capacities (70.2 ± 14.7% predicted) and DlCO (64.5 ± 19.9%). The most common PFT patterns were restrictive physiology (74%) and isolated low DlCO (13%). Decreased DLCO was associated with thrombocytosis (p = 0.05), with hepatic dysfunction (elevated alanine aminotransferase; p = 0.07), and a trend toward renal dysfunction (elevated blood urea nitrogen and creatinine; p = 0.05 and 0.07, respectively). Conclusions: Pulmonary function is abnormal in 90% of adult patients with Hb-SS. Common abnormalities include restrictive physiology and decreased DLCO. Decreased DLCO may indicate more severe sickle vasculopathy characterized by impaired hepatic and renal function. PMID:16556694
NASA Astrophysics Data System (ADS)
Wormanns, Dag; Beyer, Florian; Hoffknecht, Petra; Dicken, Volker; Kuhnigk, Jan-Martin; Lange, Tobias; Thomas, Michael; Heindel, Walter
2005-04-01
This study was aimed to evaluate a morphology-based approach for prediction of postoperative forced expiratory volume in one second (FEV1) after lung resection from preoperative CT scans. Fifteen Patients with surgically treated (lobectomy or pneumonectomy) bronchogenic carcinoma were enrolled in the study. A preoperative chest CT and pulmonary function tests before and after surgery were performed. CT scans were analyzed by prototype software: automated segmentation and volumetry of lung lobes was performed with minimal user interaction. Determined volumes of different lung lobes were used to predict postoperative FEV1 as percentage of the preoperative values. Predicted FEV1 values were compared to the observed postoperative values as standard of reference. Patients underwent lobectomy in twelve cases (6 upper lobes; 1 middle lobe; 5 lower lobes; 6 right side; 6 left side) and pneumonectomy in three cases. Automated calculation of predicted postoperative lung function was successful in all cases. Predicted FEV1 ranged from 54% to 95% (mean 75% +/- 11%) of the preoperative values. Two cases with obviously erroneous LFT were excluded from analysis. Mean error of predicted FEV1 was 20 +/- 160 ml, indicating absence of systematic error; mean absolute error was 7.4 +/- 3.3% respective 137 +/- 77 ml/s. The 200 ml reproducibility criterion for FEV1 was met in 11 of 13 cases (85%). In conclusion, software-assisted prediction of postoperative lung function yielded a clinically acceptable agreement with the observed postoperative values. This method might add useful information for evaluation of functional operability of patients with lung cancer.
Li, F; Sun, Z; Li, H; Yang, T; Shi, Z
2018-04-01
Chronic obstructive pulmonary disease (COPD) is a leading cause of hospital admissions, which can result in a significant financial burden. To determine hospitalisation costs and factors associated with higher costs in patients with acute exacerbations of COPD (AE-COPD). Patients hospitalised for a whole year formed the study cohort. Demographic features, clinical data and hospitalisation bills were evaluated retrospectively. Student's t-test or the Mann-Whitney U-test were used to compare the mean values of variables between high-cost and low-cost groups. Logistic regression analysis was used to study the relationship between hospitalisation costs with clinical factors. A total of 188 patients were evaluated. The mean length of stay in hospital (LOSH) was 8.5 days. The mean cost of AE-COPD was US$1722.0. Costs were significantly associated with LOSH and the per cent predicted value of forced expiratory volume in one second. Age, sex, smoking index, partial oxygen pressure, partial carbon dioxide pressure, haemoglobin concentration and white blood cell counts were not associated with hospitalisation costs. Medications and laboratory services are the main drivers of hospitalisation costs in AE-COPD. Longer LOSH and reduced pulmonary function determine the high costs in hospitalised patients with AE-COPD admitted to a general ward. To reduce hospitalisation costs, more emphasis should be placed on shortening LOSH and preventing the worsening of pulmonary function.
Effect of added mass on treadmill performance and pulmonary function.
Walker, Rachel E; Swain, David P; Ringleb, Stacie I; Colberg, Sheri R
2015-04-01
Military personnel engage in strenuous physical activity and load carriage. This study evaluated the role of body mass and of added mass on aerobic performance (uphill treadmill exercise) and pulmonary function. Performance on a traditional unloaded run test (4.8 km) was compared with performance on loaded tasks. Subjects performed an outdoor 4.8-km run and 4 maximal treadmill tests wearing loads of 0, 10, 20, and 30 kg. Subjects' pulmonary function (forced expired volume in 1 second [FEV1], forced vital capacity [FVC], and maximal voluntary ventilation [MVV]) was tested with each load, and peak values of heart rate, oxygen consumption ((Equation is included in full-text article.)), ventilation (VE), and respiratory exchange ratio (RER) were measured during each treadmill test. Performance on the 4.8-km run was correlated with treadmill performance, measured as time to exhaustion (TTE), with the strength of the correlation decreasing with load (r = 0.87 for 0 kg to 0.76 for 30 kg). Body mass was not correlated with TTE, other than among men with the 30-kg load (r = 0.48). During treadmill exercise, all peak responses other than RER decreased with load. Pulmonary function measures (FEV1, FVC, and MVV) decreased with load. Body mass was poorly correlated with treadmill performance, but added mass decreased performance. The decreased performance may be in part because of decreased pulmonary function. Unloaded 4.8-km run performance was correlated to unloaded uphill treadmill performance, but less so as load increased. Therefore, traditional run tests may not be an effective means of evaluating aerobic performance for military field operations.
Jalalian, Rozita; Moghadamnia, Ali Akbar; Tamaddoni, Ahmad; Khafri, Soraya; Iranian, Mohammadreza
2017-07-01
Conventional oral therapies in the management of pulmonary hypertension in people without haemoglobinopathies are of limited value in thalassaemia patients because of toxicity and poor effectiveness. This study was conducted to assess the effect of tadalafil on pulmonary artery pressure and right ventricular systolic function in patients with beta-thalassaemia intermedia. Forty-four patients with beta-thalassaemia intermedia with pulmonary hypertension based on transthoracic echocardiography (TTE) were entered in the study. Patients with hepatic or renal insufficiency and also patients who were treated with organic nitrates or alpha-blockers were excluded. The patients were randomly divided into two groups (n=22) and they were treated for six weeks with tadalafil (40mg daily) or placebo. The pulmonary artery systolic pressure (PASP), tricuspid regurgitation velocity (TRV) and parameters related to systolic function of the right ventricle were measured by the TTE before and after treatment. Significant improvement in TRV (3.02±0.02 m/s-2.52±0.06 m/s), PASP (45.31±0.66 mmHg-34.26±1.15mmHg) and parameters related to systolic function of the right ventricle were observed in the group who received tadalafil compared to placebo (p< 0.05). Tadalafil significantly decreased PASP and TRV in patients with beta-thalassaemia intermedia. Likewise, tadalafil improved right ventricular systolic function in the patients. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Núñez, Belen; Sauleda, Jaume; Garcia-Aymerich, Judith; Noguera, Aina; Monsó, Eduard; Gómez, Federico; Barreiro, Esther; Marín, Alicia; Antó, Josep Maria; Agusti, Alvar
2016-07-01
The origin of systemic inflammation in chronic obstructive pulmonary disease (COPD) patients remains to be defined, but one of the most widely accepted hypothesis is the 'spill over' of inflammatory mediators from the lung to the circulation. To evaluate the relationship between pulmonary and systemic inflammation in COPD quantifying several inflammatory markers in sputum and serum determined simultaneously. Correlations between various inflammatory variables (TNF-α, IL6, IL8) in sputum and serum were evaluated in 133 patients from the PAC-COPD cohort study. A secondary objective was the evaluation of relationships between inflammatory variables and lung function. Inflammatory markers were clearly higher in sputum than in serum. No significant correlation was found (absolute value, r=0.03-0.24) between inflammatory markers in blood and in sputum. There were no significant associations identified between those markers and lung function variables, such as FEV1, DLCO and PaO2 neither. We found no correlation between pulmonary and systemic inflammation in patients with stable COPD, suggesting different pathogenic mechanisms. Copyright © 2016 SEPAR. Published by Elsevier Espana. All rights reserved.
Pugh, Meredith E.; Newman, Alexander L.; Robbins, Ivan M.; Tolle, James; Austin, Eric D.; Newman, John H.
2011-01-01
Background: CO2 excretion is impaired in pulmonary arterial hypertension (PAH) due to underlying vascular obstruction and increased dead space. Our aim was to determine whether resting end tidal CO2 (Etco2) could differentiate patients with PAH from those with pulmonary venous hypertension (PVH) or patients without pulmonary hypertension (PH) and whether successful treatment of PAH resulted in higher Etco2 values. Methods: We performed Etco2 measurements for five breaths at rest and after a 6-min walk test (6MWT) in patients seen at our pulmonary vascular center. Mean Etco2 values were correlated with 6-min walk distance and right-sided heart catheterization data. Results: We enrolled 84 patients with PAH, 17 with PVH without left ventricular systolic dysfunction, and seven with no PH and no severe alterations in pulmonary function testing. Etco2 was significantly lower in patients with PAH than in those with no PH and PVH (P < .0001 PAH vs both groups). Etco2 correlated with the pulmonary artery diastolic pressure-to-pulmonary artery occlusion pressure gradient (r = −0.50, P = .0002) and pulmonary vascular resistance (r = −0.44, P = .002). Etco2 after 6MWT correlated with walk distance (r = 0.34, P = .003). In patients with prostaglandin therapy escalation, Etco2 increased in those who had clinical improvement, whereas in patients who did not improve clinically, Etco2 failed to rise (P = .04). Conclusions: Etco2 is a promising tool to differentiate patients with PAH from those with PVH or no PH, correlates with diagnostic and prognostic hemodynamic indicators, and may increase with successful treatment of PAH. PMID:21622547
Thurman, Andrew L; Choi, Jiwoong; Choi, Sanghun; Lin, Ching-Long; Hoffman, Eric A; Lee, Chang Hyun; Chan, Kung-Sik
2017-05-10
Methacholine challenge tests are used to measure changes in pulmonary function that indicate symptoms of asthma. In addition to pulmonary function tests, which measure global changes in pulmonary function, computed tomography images taken at full inspiration before and after administration of methacholine provide local air volume changes (hyper-inflation post methacholine) at individual acinar units, indicating local airway hyperresponsiveness. Some of the acini may have extreme air volume changes relative to the global average, indicating hyperresponsiveness, and those extreme values may occur in clusters. We propose a Gaussian mixture model with a spatial smoothness penalty to improve prediction of hyperresponsive locations that occur in spatial clusters. A simulation study provides evidence that the spatial smoothness penalty improves prediction under different data-generating mechanisms. We apply this method to computed tomography data from Seoul National University Hospital on five healthy and ten asthmatic subjects. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Bombicz, Mariann; Priksz, Daniel; Varga, Balazs; Kurucz, Andrea; Kertész, Attila; Takacs, Akos; Posa, Aniko; Kiss, Rita; Szilvassy, Zoltan; Juhasz, Bela
2017-01-01
Right-sided heart failure—often caused by elevated pulmonary arterial pressure—is a chronic and progressive condition with particularly high mortality rates. Recent studies and our current findings suggest that components of Wild garlic (Allium ursinum, AU) may play a role in reducing blood pressure, inhibiting angiotensin-converting enzyme (ACE), as well as improving right ventricle function in rabbit models with heart failure. We hypothesize that AU may mitigate cardiovascular damage caused by pulmonary arterial hypertension (PAH) and has value in the supplementary treatment of the complications of the disease. In this present investigation, PAH was induced by a single dose of monocrotaline (MCT) injection in Sprague-Dawley rats, and animals were divided into 4 treatment groups as follows: I. healthy control animals (Control group); II. pulmonary hypertensive rats (PAH group); III. pulmonary hypertensive rats + daily sildenafil treatment (Sildenafil group); and IV. pulmonary hypertensive rats + Wild garlic liophylisate-enriched chow (WGLL group), for 8 weeks. Echocardiographic measurements were obtained on the 0 and 8 weeks with fundamental and Doppler imaging. Isolated working heart method was used to determinate cardiac functions ex vivo after thoracotomy on the 8th week. Histological analyses were carried out on excised lung samples, and Western blot technique was used to determine Phosphodiesterase type 5 enzyme (PDE5) expression in both myocardial and pulmonary tissues. Our data demonstrate that right ventricle function measured by echocardiography was deteriorated in PAH animals compared to controls, which was counteracted by AU treatment. Isolated working heart measurements showed elevated aortic flow in WGLL group compared to PAH animals. Histological analysis revealed dramatic increase in medial wall thickness of pulmonary arteries harvested from PAH animals, but arteries of animals in sildenafil- and WGLL-treated groups showed physiological status. Our results suggest that bioactive compounds in Allium ursinum could have beneficial effects in pulmonary hypertension. PMID:28677661
Miller, Melissa R; Sokol, Ronald J; Narkewicz, Michael R; Sontag, Marci K
2012-05-01
Severe liver disease affects 4.5% to 10% of individuals with cystic fibrosis (CF) and is the third-leading cause of death. Liver transplantation (LT) is an accepted therapy, but the effects of liver disease and LT on pulmonary function in patients with CF are controversial. Our aim was to characterize changes in pulmonary function in LT patients with CF. Using mixed effect models, we analyzed pulmonary function before and after transplantation in 168 LT patients and 840 non-LT patients with CF who were matched by age, sex, pancreatic status, infections with US CF Foundation Patient Registry data (1989-2007). The primary outcome was the change in the forced expiratory volume in 1 second (FEV(1); percent predicted) in LT and non-LT in the 3-years periods before or after transplantation; second we compared FEV(1) changes. In the 3 years before transplantation, LT had lower initial FEV(1) values (71.5% ± 1.9%, P < 0.001) and a slower decline (+0.1% ± 0.4%/year, P < 0.001) than non-LT (79.6% ± 1.3% and -1.3% ± 0.2%/year, respectively). There was no difference in the FEV(1) decline after transplantation (-1.4% ± 0.4%/year for LT versus -2.1% ± 0.2%/year for non-LT, P = 0.14). Both the (P = 0.003) and (P = 0.001) had a slower FEV(1) decline in the period before transplantation versus after transplantation. In conclusion, pulmonary function is lower and declines more slowly in patients with CF before LT versus, but parallels the decline in non-LT after transplantation. LT is neither beneficial nor detrimental to pulmonary function in CF but returns FEV(1) decline to the same trajectory found for matched non-LT individuals with CF. Copyright © 2012 American Association for the Study of Liver Diseases.
Schäfer, Julia Carmen; Haubenreisser, Holger; Meyer, Mathias; Grüttner, Joachim; Walter, Thomas; Borggrefe, Martin; Schoepf, Joseph U; Nance, John W; Schönberg, Stefan O; Henzler, Thomas
2018-06-01
To prospectively evaluate the feasibility of single contrast bolus high-pitch CT pulmonary angiography (CTPA) subsequently followed by low-dose retrospectively ECG-gated cardiac CT (4D-cCT) in patients with suspected pulmonary embolism (PE) to accurately evaluate right ventricular (RV) function. 62 patients (33 female, age 65.1 ± 17.5 years) underwent high-pitch CTPA examination with 80cc of iodinated contrast material. 5 s after the end of the high-pitch CTPA study, a low-dose retrospectively ECG-gated cardiac CT examination was automatically started. The volume CT dose index (CTDI vol) and dose length product (DLP) were recorded in all patients and the effective dose was calculated. For the assessment of image quality, attenuation was measured as Hounsfield units (HUs) within various regions of interest (ROIs). These ROIs were used to calculate the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality was assessed using a five-point Likert scale. On 4D-cCT, the ejection fraction of both ventricles (RVEF, LVEF) as well as the ratio of RVEF and LVEF (RVEF/LVEF) was assessed. The statistical difference of all parameters between the PE and non-PE group was calculated. The mean effective radiation dose was 4.22 ± 2.05 mSv. Attenuation measurements on CTPA showed the highest attenuation values in the main pulmonary artery (442.01 ± 187.64). On 4D-cCT attenuation values were highest in the descending aorta (560.59 ± 208.81). The CNR and SNR values on CTPA were highest within the main pulmonary artery (CNR = 12.43 ± 4.57; SNR = 15.14 ± 4.90). On 4D-cCT images, the highest SNR and CNR could be measured in the descending aorta (CNR = 10.26 ± 5.57; SNR = 10.86 ± 5.17). The mean LVEF was 60.73 %± 14.65 %, and the mean RVEF was 44.90 %± 9.54 %. The mean RVEF/LVEF was 0.79 ± 0.29. There was no significant difference between the PE and non-PE group for either of the parameters. The investigated combined CTPA and 4D-cCT protocol is feasible using a single contrast bolus and allows the evaluation of RV function in patients with suspected PE. Further studies have to evaluate the additional value of this protocol regarding risk stratification in patients with PE. · High-pitch CTPA is fast enough to leave sufficient contrast material within the heart that can be used for an additional low-dose functional cardiac CT examination.. · The tube current of the evaluated 4D-cCT is reduced over the entire cardiac cycle without any full dose peak.. · Low-dose cardiac CT subsequently performed after high-pitch CTPA allows for detailed analysis of RV function.. · Schäfer JC, Haubenreisser H, Meyer M et al. Feasibility of a Single Contrast Bolus High-Pitch Pulmonary CT Angiography Protocol Followed by Low-Dose Retrospectively ECG-Gated Cardiac CT in Patients with Suspected Pulmonary Embolism. Fortschr Röntgenstr 2018; 190: 542 - 550. © Georg Thieme Verlag KG Stuttgart · New York.
Effects of nitrogen dioxide on pulmonary function in human subjects: an environmental chamber study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kerr, H.D.; Kulle, T.J.; McIlhany, M.L.
Twenty human subjects with asthma and chronic bronchitis and 10 normal, healthy adults were exposed to 0.5 ppM of nitrogen dioxide for 2 h in an environmental chamber. Seven of the 13 subjects with asthma experienced symptoms with exposure, while only one each of the subjects with chronic bronchitis and the healthy, normal group experienced symptoms. Significant pulmonary function changes from control values with exposure to NO/sub 2/ were observed in decreased quasistatic compliance for the 10 normal subjects and the 20 subjects with asthma and chronic bronchitis. In addition, functional residual capacity increased significantly for the 20 subjects withmore » asthma and chronic bronchitis. The subjects with asthma and the subjects with chronic bronchitis as separate groups, however, did not show any significant changes with exposure. With this study we are reasonably confident that exposure of subjects with asthma and chronic bronchitis to 0.5 ppM NO/sub 2/ for 2 h does not produce a significant decrement in their pulmonary function.« less
Danielsbacka, Jenny S; Olsén, Monika Fagevik; Hansson, Per-Olof; Mannerkorpi, Kaisa
2018-03-01
Acute pulmonary embolism (PE) is a cardiovascular disease with symptoms including respiratory associated chest pain (RACP) and dyspnea. No previous studies exist focusing on lung function, functional capacity, and respiratory symptoms at discharge after PE. The aim was to examine and describe lung function, functional capacity, and respiratory symptoms at discharge in patients with PE and compare to reference values. Fifty consecutive patients with PE admitted to the Acute Medical Unit, Sahlgrenska University Hospital, were included. Size of PE was calculated by Qanadli score (QS) percentage (mean QS 33.4% (17.6)). FVC and FEV 1 were registered and 6-minute walk test (6MWT) performed at the day of discharge. RACP was rated before and after spirometry/6MWT with the Visual Analogue Scale. Perceived exertion was rated with Borg CR-10 scale. Spirometry and 6MWT results were compared with reference values. This study shows that patients with PE have significantly reduced lung function (p < 0.05) and functional capacity (p < 0.001) at discharge compared with reference values. Patients with higher QS percentage were more dyspneic after 6MWT, no other significant differences in lung function or functional capacity were found between the groups. The patients still suffer from RACP (30%) and dyspnea (60%) at discharge. This study indicates that patients with PE have a reduced lung function, reduced functional capacity, and experience respiratory symptoms as pain and dyspnea at discharge. Further studies are needed concerning long-term follow-up of lung function, functional capacity, and symptoms after PE.
The effect of exposure to SO2 on the respiratory system of power-station workers.
Froom, P; Sackstein, G; Cohen, C; Lerman, Y; Kristal-Boneh, E; Ribak, J
1998-01-01
Sulfur dioxide (SO2) is generally recognized as a respiratory irritant, but its effects if any at low levels of exposure are uncertain. We studied 38 power station technicians exposed to 0.8 ppm (parts per million) 8-h weighted levels of sulfur dioxide, and compared them to workers performing similar tasks without such exposure. Those exposed complained 5.8 times more frequently of cough (95% CI =1.8-20.6, P < 0.001), and also had significantly more sputum production. There was also a trend for increasing prevalence of dyspnea. On the other hand there was no decrease in pulmonary function test values. In the eight exposed subjects who complained of dyspnea, there was a significant decrease in pulmonary flow values. We conclude that power station workers exposed to low levels of SO2 have increased respiratory symptoms, and deserve compensation if their symptoms become chronic. The pulmonary function tests were not different from the control subjects, but there may be a small group who are prone to long-term morbidity. Additional studies are warranted to confirm our findings, and to define immediate and long-term morbidity due to low exposure to SO2.
Impaired pulmonary function after treatment for tuberculosis: the end of the disease?
Chushkin, Mikhail Ivanovich; Ots, Oleg Nikolayevich
2017-01-01
ABSTRACT Objective: To evaluate the prevalence of pulmonary function abnormalities and to investigate the factors affecting lung function in patients treated for pulmonary tuberculosis. Methods: A total of 214 consecutive patients (132 men and 82 women; 20-82 years of age), treated for pulmonary tuberculosis and followed at a local dispensary, underwent spirometry and plethysmography at least one year after treatment. Results: Pulmonary impairment was present in 102 (47.7%) of the 214 patients evaluated. The most common functional alteration was obstructive lung disease (seen in 34.6%). Of the 214 patients, 60 (28.0%) showed reduced pulmonary function (FEV1 below the lower limit of normal). Risk factors for reduced pulmonary function were having had culture-positive pulmonary tuberculosis in the past, being over 50 years of age, having recurrent tuberculosis, and having a lower level of education. Conclusions: Nearly half of all tuberculosis patients evolve to impaired pulmonary function. That underscores the need for pulmonary function testing after the end of treatment. PMID:28380187
Heydari, Abbas; Farzad, Marjan; Ahmadi hosseini, Seyed-hossein
2015-01-01
To examine the effect of incentive spirometry in pulmonary rehabilitation of chronic obstructive pulmonary disease (COPD) patients and compare its efficacy with inspiratory resistive muscle training (IMT) technique. Randomized controlled trial. Thirty patients with COPD, from a general hospital in Mashhad, Iran, were randomly assigned to two study groups. All subjects trained daily in two 15-minute sessions, 4 days a week, for 4 weeks. Respiratory function tests were compared before interventions and at the end of weeks 2 and 4. Both techniques improved the mean values of all respiratory function tests (p≤.01). The IMT technique was more effective to improve MVV and PImax (p≤.05). PEFR was better improved in the incentive spirometry group (p≤.05). There was no significant difference for other spirometric parameters between two groups. Incentive spirometry can be considered as an effective component for pulmonary rehabilitation in COPD patients. © 2013 Association of Rehabilitation Nurses.
Camiciottoli, G; Diciotti, S; Bartolucci, M; Orlandi, I; Bigazzi, F; Matucci-Cerinic, M; Pistolesi, M; Mascalchi, M
2013-03-01
Spiral low-dose computed tomography (LDCT) permits to measure whole-lung volume and density in a single breath-hold. To evaluate the agreement between static lung volumes measured with LDCT and pulmonary function test (PFT) and the correlation between the LDCT volumes and lung density in restrictive lung disease. Patients with Systemic Sclerosis (SSc) with (n = 24) and without (n = 16) pulmonary involvement on sequential thin-section CT and patients with chronic obstructive pulmonary disease (COPD)(n = 29) underwent spirometrically-gated LDCT at 90% and 10% of vital capacity to measure inspiratory and expiratory lung volumes and mean lung attenuation (MLA). Total lung capacity and residual volume were measured the same day of CT. Inspiratory [95% limits of agreement (95% LoA)--43.8% and 39.2%] and expiratory (95% LoA -45.8% and 37.1%) lung volumes measured on LDCT and PFT showed poor agreement in SSc patients with pulmonary involvement, whereas they were in substantial agreement (inspiratory 95% LoA -14.1% and 16.1%; expiratory 95% LoA -13.5% and 23%) in SSc patients without pulmonary involvement and in inspiratory scans only (95% LoA -23.1% and 20.9%) of COPD patients. Inspiratory and expiratory LDCT volumes, MLA and their deltas differentiated both SSc patients with or without pulmonary involvement from COPD patients. LDCT lung volumes and density were not correlated in SSc patients with pulmonary involvement, whereas they did correlate in SSc without pulmonary involvement and in COPD patients. In restrictive lung disease due to SSc there is poor agreement between static lung volumes measured using LDCT and PFT and the relationship between volume and density values on CT is altered.
Alonso, Pau; Andrés, Ana; Rueda, Joaquín; Buendía, Francisco; Igual, Begoña; Rodríguez, María; Osa, Ana; Arnau, Miguel A; Salvador, Antonio
2015-05-01
Pulmonary regurgitation is a common complication in patients with repaired tetralogy of Fallot or congenital pulmonary stenosis. Electrocardiographic variables have been correlated with parameters used to evaluate right ventricular function. We aimed to analyze the diagnostic value of the width and fragmentation of the electrocardiogram in the identification of patients with right ventricular dysfunction and/or dilation. We selected 107 consecutive patients diagnosed with severe pulmonary insufficiency after repair of pulmonary stenosis or tetralogy of Fallot. The tests included electrocardiography, echocardiography, and magnetic resonance. Each electrocardiogram was analyzed manually to measure QRS duration. We defined QRS fragmentation as the presence of low-voltage waves in the terminal portion of the QRS complex in at least 2 contiguous leads. We found a significant negative correlation between QRS width and right ventricular function, as well as a positive correlation with right ventricular volume. The receiver operating characteristic curve indicated a cut-off point for QRS width of 140ms, which showed good sensitivity for a diagnosis of right ventricular dilation (> 80%) and dysfunction (> 95%). In logistic regression models, a QRS duration > 140ms was found to be the only independent predictor of right ventricular dilation and dysfunction. Electrocardiography is a rapid, widely available, and reproducible tool. QRS width constitutes an independent predictor of the presence of right ventricular dilation and dysfunction. This study is the first to provide a cutoff value for QRS width to screen for right ventricle involvement. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
2012-01-01
Background Rapid and accurate diagnosis and management can be lifesaving for patients with acute dyspnea. However, making a differential diagnosis and selecting early treatment for patients with acute dyspnea in the emergency setting is a clinical challenge that requires complex decision-making in order to achieve hemodynamic balance, improve functional capacity, and decrease mortality. In the present study, we examined the screening potential of rapid evaluation by lung-cardiac-inferior vena cava (LCI) integrated ultrasound for differentiating acute heart failure syndromes (AHFS) from primary pulmonary disease in patients with acute dyspnea in the emergency setting. Methods Between March 2011 and March 2012, 90 consecutive patients (45 women, 78.1 ± 9.9 years) admitted to the emergency room of our hospital for acute dyspnea were enrolled. Within 30 minutes of admission, all patients underwent conventional physical examination, rapid ultrasound (lung-cardiac-inferior vena cava [LCI] integrated ultrasound) examination with a hand-held device, routine laboratory tests, measurement of brain natriuretic peptide, and chest X-ray in the emergency room. Results The final diagnosis was acute dyspnea due to AHFS in 53 patients, acute dyspnea due to pulmonary disease despite a history of heart failure in 18 patients, and acute dyspnea due to pulmonary disease in 19 patients. Lung ultrasound alone showed a sensitivity, specificity, negative predictive value, and positive predictive value of 96.2, 54.0, 90.9, and 75.0%, respectively, for differentiating AHFS from pulmonary disease. On the other hand, LCI integrated ultrasound had a sensitivity, specificity, negative predictive value, and positive predictive value of 94.3, 91.9, 91.9, and 94.3%, respectively. Conclusions Our study demonstrated that rapid evaluation by LCI integrated ultrasound is extremely accurate for differentiating acute dyspnea due to AHFS from that caused by primary pulmonary disease in the emergency setting. PMID:23210515
The influence of kyphosis correction surgery on pulmonary function and thoracic volume.
Zeng, Yan; Chen, Zhongqiang; Ma, Desi; Guo, Zhaoqing; Qi, Qiang; Li, Weishi; Sun, Chuiguo; Liu, Ning; White, Andrew P
2014-10-01
A clinical study. To measure the changes in pulmonary function and thoracic volume associated with surgical correction of kyphotic deformities. No prior study has focused on the pulmonary function and thoracic cavity volume before and after corrective surgery for kyphosis. Thirty-four patients with kyphosis underwent posterior deformity correction with instrumented fusion. Preoperative and postoperative pulmonary function was measured, and pulmonary function grade was evaluated as mild, significant, or severe. The change in preoperative to postoperative pulmonary function was analyzed, using 6 comparative subgroupings of patients on the basis of age, severity of kyphosis, location of kyphosis apex, length of follow-up time after surgery, degree of kyphosis correction, and number of segments fused. A second group of 19 patients also underwent posterior surgical correction of kyphosis, which had thoracic volume measured preoperatively and postoperatively with computed tomographic scanning. All of the pulmonary impairments were found to be restrictive. After surgery, most of the patients had improvement of the pulmonary function. Before surgery, the pulmonary function differences were found to be significant based on both severity of preoperative kyphosis (<60° vs. >60°) and location of the kyphosis apex (above T10 vs. below T10). Younger patients (younger than 35 yr) were more likely to exhibit statistically significant improvements in pulmonary function after surgery. However, thoracic volume was not significantly related to pulmonary function parameters. After surgery, average thoracic volume had no significant change. The major pulmonary impairment caused by kyphosis was found to be restrictive. Patients with kyphosis angle of 60° or greater or with kyphosis apex above T10 had more severe pulmonary dysfunction. Patients' age was significantly related to change in pulmonary function after surgery. However, the average thoracic volume had no significant change after surgery. 3.
Takai, Daiya
2014-12-01
Spirometry and the flow-volume curve test are commonly performed lung function tests. However, a unique clinical entity occasionally shows almost normal data in these tests, and is therefore missed on screening tests. The clinical entity of combined pulmonary emphysema and pulmdoary fibrosis was recognized and documented in the 90's in Japan, the USA, and Europe. Typical emphysema shows obstructive disorders, and pulmonary fibrosis shows restrictive disorders. Thus, the combination of both should lead to a combined disorder pattern in lung function tests, but this is not the case. In 2005, Cottin reported and redefined this combination of emphysema and fibrosis of the lung as "Combined Pulmonary Fibrosis and Emphysema" (CPFE). The patients are typically heavily smoking males who show an almost normal lung function. The upper lobe of these patients usually shows severe emphysema, which contributes to a static volume and a late phase in the forced volume test. On the other hand their lower lobe shows fibrotic change. The fibrotic portion contributes to early phase flow in the flow-volume curve. These mechanisms are a reason for the normal pattern appearance in lung function tests in CPFE patients. As a matter of course, these patients have damaged upper and lower lobes: their diffusing capacity of the lung shows a low performance, their saturation of blood hemoglobin decreases soon after light exercise, and their KL-6 (a blood marker of pulmonary fibrosis) usually shows a high value. They are considered a high risk group regarding complications of post-surgical treatment. Thus, when medical technologists identify suspicious cases, they should advise doctors to add diffusing capacity and KL-6 tests. (Review).
Corey, P; Hutcheon, M; Broder, I; Mintz, S
1982-01-01
The purpose of this study was to determine whether grain handlers underwent work-related changes in their pulmonary function and, if so, to examine the dose-effect relationships with dust exposure. The pulmonary function of grain handlers was measured at the beginning and end of work shifts over a period of one week, during which their exposure to dust was measured daily. The results showed changes indicative of a within-day obstructive change, in addition to a small restrictive defect occurring over the course of a week. Civic outside labourers who were examined as a control group showed a similar within-week obstructive change without any associated restriction of lung volume. The data on the grain handlers were also used to examine the dose-effect relationships of dust exposure, both on baseline pulmonary function and on within-day changes in these measurements. The baseline flow rates of workers who did not wear a mask were found to vary inversely with their average exposure to respirable dust. In addition, the flow rates underwent a within-day decrease that varied directly with their corresponding exposure to respirable dust and was unrelated to mask wearing. The median of the slopes for this relationship indicated that 50% of the subjects had a decrease of at least 923 ml/s in the value of their Vmax50%VC for each 1 mg/m3 increase in the concentration of respirable dust. Non-respirable dust did not have a measurable effect either on the baseline or the within-day changes in pulmonary function. The acute changes were unaffected by age, duration of employment, or extent of smoking. PMID:7138793
Acar, Onur Çağlar; Üner, Abdurrahman; Garça, Mehmet Fatih; Ece, İbrahim; Epçaçan, Serdar; Turan, Mahfuz; Kalkan, Ferhat
2016-06-01
The purpose of the present study is to emphasize the efficacy of the myocardial performance index and tricuspid annular plane systolic excursion (TAPSE) in the determination of impaired cardiac functions and recovery period following the treatment in children with adenoid and/or tonsillar hypertrophy. Fifty-three healthy children after routine laboratory, imaging and clinical examinations, with adenoid and/or tonsillar hypertrophy were evaluated before and 3 months after adenotonsillectomy for cardiac functions using M mode and Doppler echocardiography. The mean age of cases was 6.4±3.0 years, 34 (65%) were male, and 19 (35%) were female. Pulmonary hypertension was observed to be mild in 3 patients and moderate in 1 patient preoperatively. When the preoperative and postoperative echocardiographic measurements of the patients were compared, the tricuspid valve E wave velocity, the E/A ratio (E, early diastolic flow rate; A, late diastolic flow rate), and the TAPSE values were determined to be significantly higher postoperatively (P<0.05). The tricuspid valve deceleration time, the isovolumetric relaxation time and the systolic pulmonary artery pressure were found to be significantly lower compared to the preoperative values (P<0.05). Adenoidectomy and/or tonsillectomy may prevent cardiac dysfunctions that can develop in the later periods due to adenoid and/or tonsil hypertrophy in children, before the appearance of the clinical findings of cardiac failure.
PULMONARY CIRCULATION AT EXERCISE
NAEIJE, R; CHESLER, N
2012-01-01
The pulmonary circulation is a high flow and low pressure circuit, with an average resistance of 1 mmHg.min.L−1 in young adults, increasing to 2.5 mmHg.min.L−1 over 4–6 decades of life. Pulmonary vascular mechanics at exercise are best described by distensible models. Exercise does not appear to affect the time constant of the pulmonary circulation or the longitudinal distribution of resistances. Very high flows are associated with high capillary pressures, up to a 20–25 mmHg threshold associated with interstitial lung edema and altered ventilation/perfusion relationships. Pulmonary artery pressures of 40–50 mmHg, which can be achieved at maximal exercise, may correspond to the extreme of tolerable right ventricular afterload. Distension of capillaries that decrease resistance may be of adaptative value during exercise, but this is limited by hypoxemia from altered diffusion/perfusion relationships. Exercise in hypoxia is associated with higher pulmonary vascular pressures and lower maximal cardiac output, with increased likelihood of right ventricular function limitation and altered gas exchange by interstitial lung edema. Pharmacological interventions aimed at the reduction of pulmonary vascular tone have little effect on pulmonary vascular pressure-flow relationships in normoxia, but may decrease resistance in hypoxia, unloading the right ventricle and thereby improving exercise capacity. Exercise in patients with pulmonary hypertension is associated with sharp increases in pulmonary artery pressure and a right ventricular limitation of aerobic capacity. Exercise stress testing to determine multipoint pulmonary vascular pressures-flow relationships may uncover early stage pulmonary vascular disease. PMID:23105961
Spirometric reference values for Hopi Native American children ages 4-13 years.
Arnall, David A; Nelson, Arnold G; Hearon, Christopher M; Interpreter, Christina; Kanuho, Verdell
2016-04-01
Spirometry is the most important tool in diagnosing pulmonary disease and is the most frequently performed pulmonary function test. Respiratory disease is also one of the greatest causes for morbidity and mortality on the Hopi Nation, but no specific reference equations exist for this unique population. The purpose of this study was to determine if population reference equations were necessary for these children and, if needed, to create new age and race-specific pulmonary nomograms for Hopi children. Two hundred and ninety-two healthy children, ages 4-13 years, attending Hopi Nation elementary schools in Arizona, were asked to perform spirometry for a full battery of pulmonary volumes and capacities of which the following were analyzed: forced vital capacity (FVC), forced expiratory volume in 1 sec (FEV1 ), FEV1 % (FEV1 /FVC), FEF25-75% and peak expiratory flow rate (PEFR). Spirometric data from Navajo children living in the same geographical region as the Hopi children were compared as well as spirometric data from common reference values used for other ethnic groups in the USA. Spirometry tests from 165 girls and 127 boys met American Thoracic Society quality control standards. We found that the natural log of height, body mass and age were significant predictors of FEV1 , FVC, and FEF25-75% in the gender-specific models and that lung function values all increased with height and age as expected. The predictions using the equations derived for Navajo, Caucasian, Mexican-American, African-American youth were significantly different (P ≤ 0.05) from the predictions derived from the Hopi equations for all of the variables across both genders, with the exceptions of Hopi versus Navajo FEV1 /FVC in the males and Hopi versus Caucasians FEF25-75% in the females. Thus it would appear for this population important to have specific formulae to provide more accurate reference values. © 2015 Wiley Periodicals, Inc.
Diagnostic management of chronic obstructive pulmonary disease.
Broekhuizen, B D L; Sachs, A P E; Hoes, A W; Verheij, T J M; Moons, K G M
2012-01-01
Detection of early chronic obstructive pulmonary disease (COPD) in patients presenting with respiratory symptoms is recommended; however, diagnosing COPD is difficult because a single gold standard is not available. The aim of this article is to review and interpret the existing evidence, theories and consensus on the individual parts of the diagnostic work-up for COPD. Relevant articles are discussed under the subheadings: history taking, physical examination, spirometry and additional lung function assessment. Wheezing, cough, phlegm and breathlessness on exertion are suggestive signs for COPD. The diagnostic value of the physical examination is limited, except for auscultated pulmonary wheezing or reduced breath sounds, increasing the probability of COPD. Spirometric airflow obstruction after bronchodilation, defined as a lowered ratio of the forced volume in one second to the forced vital capacity (FEV1/FVC ratio), is a prerequisite, but can only confirm COPD in combination with suggestive symptoms. Different thresholds are being recommended to define low FEV1/FVC, including a fixed threshold, and one varying with gender and age; however, the way physicians interpret these thresholds in their assessment is not well known. Body plethysmography allows a more complete assessment of pulmonary function, providing results on the total lung capacity and the residual volume and is indicated when conventional spirometry results are inconclusive. Chest radiography has no diagnostic value for COPD but is useful to exclude alternative diagnoses such as heart failure or lung cancer. Extensive history taking is of key importance in diagnosing COPD.
Li, Wen; Wang, Lei; Xiong, Chang-Ming; Yang, Tao; Zhang, Yan; Gu, Qing; Yang, Yong; Ni, Xin-Hai; Liu, Zhi-Hong; Fang, Wei; He, Jian-Guo
2015-11-01
Metabolic changes occur in the right ventricle (RV) under increased afterload in pulmonary arterial hypertension. FDG PET imaging has potential to assess RV function. In this study, we aimed to determine the prognostic value of metabolic changes of RV using FDG PET imaging in idiopathic pulmonary arterial hypertension (IPAH). In this prospective investigation, patients newly diagnosed with IPAH were recruited. Patients underwent right heart catheterization, FDG PET imaging, and cardiac MR (CMR) within 1 week. Right ventricle hemodynamics, glucose metabolism derived from the FDG uptake levels, and functional parameters were obtained. The FDG uptake ratio between the RV and the left ventricle (LV) and its relation with the patients' survival were analyzed. A total of 45 IPAH patients were enrolled in this study, which included 13 male (28.9%) and 32 female (71.1%). The median follow-up time of this study was 1043 days. At the end of the follow-up, 36 patients survived, whereas 9 patients were deceased because of right heart failure. Multivariate Cox proportional hazard analysis showed that the ratio between the corrected RV and LV FDG uptake (cRV/LV) in both glucose-loading (cRV/LVg) and fasting (cRV/LVf) conditions independently predicted the mortality after adjusting for pulmonary vascular resistance index, mean right atrial pressure, and World Health Organization functional class. Kaplan-Meier survival analysis showed that patients with cRV/LVf greater than 143.65% in fasting condition (log rank, P = 0.030) or cRV/LVg greater than 120.55% in glucose-loading condition (log rank, P = 0.014) had worse prognosis. The FDG uptake ratio between the RV and LV can be an independent predictor for long-term prognosis of IPAH patients.
Koulouri, Agoritsa; Gourgoulianis, Konstantinos; Hatzoglou, Chryssi; Roupa, Zoe
2014-01-01
ABSTRACT Introduction: Chronic Obstructive Pulmonary Disease (COPD) has a significant impact on quality of life-related health. Aim: It was the detection of Chronic Obstructive Pulmonary Disease by using telemetric methods and the investigation of the quality of life for people working in Shipbuilding Industry compared with a control group. Methods: A group of one hundred men working in the shipbuilding industry aged 51.8 ± 8.2 years old and a control group of one hundred men of the general population aged 51.1 ± 6.4 years were studied. All participants completed the General Health Questionnaire – 28, the Fagerstrom test and a form with demographic characteristics. Pulmonary function test results were electronically sent to a specialist for evaluation. Results: People working in the shipbuilding zone had significantly lower values (p<0.001) in FVC, FEV1 and FEV1/FVC compared with the general population participants. Worse social functionality was exhibited by workers in the shipbuilding zone, people with elementary education, unemployed and by those suffering from comorbidities (p <0.001). Conclusions: Health level and its individual dimensions are both associated with health self-assessment and occupational and economic status. The coexistence of chronic diseases and smoking dependence affects emotion and social functioning of individuals. PMID:25568580
Koulouri, Agoritsa; Gourgoulianis, Konstantinos; Hatzoglou, Chryssi; Roupa, Zoe
2014-10-01
Chronic Obstructive Pulmonary Disease (COPD) has a significant impact on quality of life-related health. It was the detection of Chronic Obstructive Pulmonary Disease by using telemetric methods and the investigation of the quality of life for people working in Shipbuilding Industry compared with a control group. A group of one hundred men working in the shipbuilding industry aged 51.8 ± 8.2 years old and a control group of one hundred men of the general population aged 51.1 ± 6.4 years were studied. All participants completed the General Health Questionnaire - 28, the Fagerstrom test and a form with demographic characteristics. Pulmonary function test results were electronically sent to a specialist for evaluation. People working in the shipbuilding zone had significantly lower values (p<0.001) in FVC, FEV1 and FEV1/FVC compared with the general population participants. Worse social functionality was exhibited by workers in the shipbuilding zone, people with elementary education, unemployed and by those suffering from comorbidities (p <0.001). Health level and its individual dimensions are both associated with health self-assessment and occupational and economic status. The coexistence of chronic diseases and smoking dependence affects emotion and social functioning of individuals.
Wang, W
1999-03-01
To explore the pathogenesis of ano-rectal diseases caused by deficiency of Qi, which is correlated with obstruction of pulmonary ventilation. The pulmonary ventilatory function was measured in 100 patients with the internal piles, the interno-external hemorrhoid and prolapse of rectum, the prolapse of anus was the principal symptom of them. Data from the 100 patients showed that 67% of them were diagnosed with the obstruction of pulmonary ventilation, the ratio was far less in the health control group. FEV 1.0 (mean +/- s) (2011.65 +/- 875) ml, MMF (1.84 +/- 1.24) L/s and PEF (2.34 +/- 1.51) L/s in male patients, (1551.54 +/- 514) ml, (1.57 +/- 0.62) L/s and (1.85 +/- 0.92) L/s in female patients, but those values were higher in the control than in the patients. The statistical analysis was performed and the difference was significant between patients and the control group (P < 0.01). The patients with ano-rectal diseases caused by deficiency of Qi accompanied with obstruction of pulmonary ventilation in different degree and varied sorts, it confirmed that the pathogenesis of ano-rectal diseases caused by deficiency of Qi is related with "sinking of pectoral Qi".
Couraud, L; Baudet, E; Martigne, C; Roques, X; Velly, J F; Laborde, N; Clerc, P
1989-01-01
Since January 1988, the Bordeaux group has performed 15 transplantations for lung disease: 9 heart-lung transplants, 1 heart + left lung, 1 double lung, 2 right lungs and 2 left lungs. The transplantations were performed for pulmonary emphysema (10 cases), pulmonary artery hypertension (2 cases), cystic fibrosis (1 case), pulmonary fibrosis (2 cases). Cardiopulmonary transplantation was not always performed because of associated heart failure but sometimes because of large intrahilar adenopathy or intractable bronchial infection. Pulmonary transplantation is recommended on the right side in cases of pulmonary fibrosis. One patient died postoperatively (ischaemia of the transplant). Four others died during the 2nd and 3rd months from poorly defined but probably infectious pulmonary syndromes. The tracheobronchial patency of the 10 survivors was 80% or 100% of the predicted value. The respiratory functional result was excellent in the short and intermediate term. Specific difficulties essentially consisted of pleural symphyses, hilar adenopathy, bronchial infection, steroid dependence of certain subjects, the difficulty of identifying the cause and treating lung opacities during the 2nd and 3rd months.
Antoniou, K M; Margaritopoulos, G A; Goh, N S; Karagiannis, K; Desai, S R; Nicholson, A G; Siafakas, N M; Coghlan, J G; Denton, C P; Hansell, D M; Wells, A U
2016-04-01
To assess the prevalence of combined pulmonary fibrosis and emphysema (CPFE) in systemic sclerosis (SSc) patients with interstitial lung disease (ILD) and the effect of CPFE on the pulmonary function tests used to evaluate the severity of SSc-related ILD and the likelihood of pulmonary hypertension (PH). High-resolution computed tomography (HRCT) scans were obtained in 333 patients with SSc-related ILD and were evaluated for the presence of emphysema and the extent of ILD. The effects of emphysema on the associations between pulmonary function variables and the extent of SSc-related ILD as visualized on HRCT and echocardiographic evidence of PH were quantified. Emphysema was present in 41 (12.3%) of the 333 patients with SSc-related ILD, in 26 (19.7%) of 132 smokers, and in 15 (7.5%) of 201 lifelong nonsmokers. When the extent of fibrosis was taken into account, emphysema was associated with significant additional differences from the expected values for diffusing capacity for carbon monoxide (DLco) (average reduction of 24.1%; P < 0.0005), and the forced vital capacity (FVC)/DLco ratio (average increase of 34.8%; P < 0.0005) but not FVC. These effects were identical in smokers and nonsmokers. Multivariate analysis showed that the presence of emphysema had a greater effect than echocardiographically determined PH on the FVC/DLco ratio, regardless of whether it was analyzed as a continuous variable or using a threshold value of 1.6 or 2.0. Among patients with SSc-related ILD, emphysema is sporadically present in nonsmokers and is associated with a low pack-year history in smokers. The confounding effect of CPFE on measures of gas exchange has major implications for the construction of screening algorithms for PH in patients with SSc-related ILD. © 2016, American College of Rheumatology.
Immunohistological features related to functional impairment in lymphangioleiomyomatosis.
Nascimento, Ellen Caroline Toledo do; Baldi, Bruno Guedes; Mariani, Alessandro Wasum; Annoni, Raquel; Kairalla, Ronaldo Adib; Pimenta, Suzana Pinheiro; da Silva, Luiz Fernando Ferraz; Carvalho, Carlos Roberto Ribeiro; Dolhnikoff, Marisa
2018-05-08
Lymphangioleiomyomatosis (LAM) is a low-grade neoplasm characterized by the pulmonary infiltration of smooth muscle-like cells (LAM cells) and cystic destruction. Patients usually present with airway obstruction in pulmonary function tests (PFTs). Previous studies have shown correlations among histological parameters, lung function abnormalities and prognosis in LAM. We investigated the lung tissue expression of proteins related to the mTOR pathway, angiogenesis and enzymatic activity and its correlation with functional parameters in LAM patients. We analyzed morphological and functional parameters of thirty-three patients. Two groups of disease severity were identified according to FEV1 values. Lung tissue from open biopsies or lung transplants was immunostained for SMA, HMB-45, mTOR, VEGF-D, MMP-9 and D2-40. Density of cysts, density of nodules and protein expression were measured by image analysis and correlated with PFT parameters. There was no difference in the expression of D2-40 between the more severe and the less severe groups. All other immunohistological parameters showed significantly higher values in the more severe group (p ≤ 0.002). The expression of VEGF-D, MMP-9 and mTOR in LAM cells was associated with the density of both cysts and nodules. The density of cysts and nodules as well as the expression of MMP-9 and VEGF-D were associated with the impairment of PFT parameters. Severe LAM represents an active phase of the disease with high expression of VEGF-D, mTOR, and MMP-9, as well as LAM cell infiltration. Our findings suggest that the tissue expression levels of VEGF-D and MMP-9 are important parameters associated with the loss of pulmonary function and could be considered as potential severity markers in open lung biopsies of LAM patients.
Nassar, Seham Zakaria; Hassaan, Passainte S; Abdelmonsif, Doaa A; ElAchy, Samar Nabil
2018-05-15
Cerium oxide nanoparticles (CeO 2 NPs) have been recently introduced into the medical field for their antioxidant properties. The ability of CeO 2 NPs alone or in combination with spironolactone (SP) to attenuate monocrotaline (MCT)-induced pulmonary hypertension and associated right ventricular hypertrophy was studied in rats. A special emphasis was given to endothelin-1 pathway. Pulmonary hypertension was induced in albino rats by a single subcutaneous injection of MCT (60 mg/kg). Rats received either single CeO 2 NPs therapy or combined therapy with SP for 2 weeks. CeO 2 NPs improved pulmonary function tests with concomitant decrease in serum endothelin-1 and pulmonary expression of endothelin-1 and its receptor ETAR. Besides, CeO 2 NPs diminished MCT-induced right ventricular hypertrophy and reduced cardiac oxidative stress and apoptosis. CeO 2 NPs could improve pulmonary hypertension and associated right ventricular hypertrophy with no additive value for SP. Besides being an antioxidant, CeO 2 NPs work through endothelin-1 pathway to improve pulmonary hypertension. Copyright © 2018 Elsevier Inc. All rights reserved.
Semi-quantitative assessment of pulmonary perfusion in children using dynamic contrast-enhanced MRI
NASA Astrophysics Data System (ADS)
Fetita, Catalin; Thong, William E.; Ou, Phalla
2013-03-01
This paper addresses the study of semi-quantitative assessment of pulmonary perfusion acquired from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in a study population mainly composed of children with pulmonary malformations. The automatic analysis approach proposed is based on the indicator-dilution theory introduced in 1954. First, a robust method is developed to segment the pulmonary artery and the lungs from anatomical MRI data, exploiting 2D and 3D mathematical morphology operators. Second, the time-dependent contrast signal of the lung regions is deconvolved by the arterial input function for the assessment of the local hemodynamic system parameters, ie. mean transit time, pulmonary blood volume and pulmonary blood flow. The discrete deconvolution method implements here a truncated singular value decomposition (tSVD) method. Parametric images for the entire lungs are generated as additional elements for diagnosis and quantitative follow-up. The preliminary results attest the feasibility of perfusion quantification in pulmonary DCE-MRI and open an interesting alternative to scintigraphy for this type of evaluation, to be considered at least as a preliminary decision in the diagnostic due to the large availability of the technique and to the non-invasive aspects.
Prediction of Spirometric Forced Expiratory Volume (FEV1) Data Using Support Vector Regression
NASA Astrophysics Data System (ADS)
Kavitha, A.; Sujatha, C. M.; Ramakrishnan, S.
2010-01-01
In this work, prediction of forced expiratory volume in 1 second (FEV1) in pulmonary function test is carried out using the spirometer and support vector regression analysis. Pulmonary function data are measured with flow volume spirometer from volunteers (N=175) using a standard data acquisition protocol. The acquired data are then used to predict FEV1. Support vector machines with polynomial kernel function with four different orders were employed to predict the values of FEV1. The performance is evaluated by computing the average prediction accuracy for normal and abnormal cases. Results show that support vector machines are capable of predicting FEV1 in both normal and abnormal cases and the average prediction accuracy for normal subjects was higher than that of abnormal subjects. Accuracy in prediction was found to be high for a regularization constant of C=10. Since FEV1 is the most significant parameter in the analysis of spirometric data, it appears that this method of assessment is useful in diagnosing the pulmonary abnormalities with incomplete data and data with poor recording.
Slottosch, Ingo; Liakopoulos, Oliver; Kuhn, Elmar; Deppe, Antje; Lopez-Pastorini, Alberto; Schwarz, David; Neef, Klaus; Choi, Yeong-Hoon; Sterner-Kock, Anja; Jung, Kristina; Mühlfeld, Christian; Wahlers, Thorsten
2014-12-01
Ischaemia/reperfusion (I/R) injury of the lungs contributes to pulmonary dysfunction after cardiac surgery with cardiopulmonary bypass (CPB), leading to increased morbidity and mortality of patients. This study investigated the value of controlled lung reperfusion strategies on lung ischaemia-reperfusion injury in a porcine CPB model. Pigs were subjected to routine CPB for 120 min with 60 min of blood cardioplegic cardiac arrest (CCA). Following CCA, the uncontrolled reperfusion (UR, n = 6) group was conventionally weaned from CPB. Two groups underwent controlled lung reperfusion strategies (CR group: controlled reperfusion conditions, n = 6; MR group: controlled reperfusion conditions and modified reperfusate, n = 6) via the pulmonary artery before CPB weaning. Sham-operated pigs (n = 7) served as controls. Animals were followed up until 4 h after CPB. Pulmonary function, haemodynamics, markers of inflammation, endothelial injury and oxidative stress as well as morphological lung alterations were analysed. CPB (UR group) induced deterioration of pulmonary function (lung mechanics, oxygenation index and lung oedema). Also, controlled lung reperfusion groups (CR and MR) presented with pulmonary dysfunction after CPB. However, compared with UR, controlled lung reperfusion strategies (CR and MR) improved lung mechanics and reduced markers of oxidative stress, but without alteration of haemodynamics, oxygenation, inflammation, endothelial injury and lung morphology. Both controlled reperfusion groups were similar without relevant differences. Controlled lung reperfusion strategies attenuated a decrease in lung mechanics and an increase in oxidative stress, indicating an influence on CPB-related pulmonary injury. However, they failed to avoid completely CPB-related lung injury, implying the need for additional strategies given the multifactorial pathophysiology of postoperative pulmonary dysfunction. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Prognostic value of exercise pulmonary haemodynamics in pulmonary arterial hypertension.
Chaouat, Ari; Sitbon, Olivier; Mercy, Magalie; Ponçot-Mongars, Raphaëlle; Provencher, Steeve; Guillaumot, Anne; Gomez, Emmanuel; Selton-Suty, Christine; Malvestio, Pascale; Regent, Denis; Paris, Christophe; Hervé, Philippe; Chabot, François
2014-09-01
The aim of the study was to investigate the prognostic value of right heart catheterisation variables measured during exercise. 55 incident patients with idiopathic, familial or anorexigen-associated pulmonary arterial hypertension (PAH) underwent right heart catheterisation at rest and during exercise and 6-min walk testing before PAH treatment initiation. Patients were treated according to recommendations within the next 2 weeks. Right heart catheterisation was repeated 3-5 months into the PAH treatment in 20 patients. Exercise cardiac index decreased gradually as New York Heart Association (NYHA) functional class increased whereas cardiac index at rest was not significantly different across NYHA groups. Baseline 6-min walk distance correlated significantly with exercise and change in cardiac index from rest to exercise (r=0.414 and r=0.481, respectively; p<0.01). Change in 6-min walk distance from baseline to 3-5 months under PAH treatment was highly correlated with change in exercise cardiac index (r=0.746, p<0.001). The most significant baseline covariates associated with survival were change in systolic pulmonary artery pressure from rest to exercise and exercise cardiac index (hazard ratio 0.56 (95% CI 0.37-0.86) and 0.14 (95% CI 0.05-0.43), respectively). Change in pulmonary haemodynamics during exercise is an important tool for assessing disease severity and may help devise optimal treat-to-target strategies. ©ERS 2014.
Koh, Myung Je; Lee, In Jae; Kim, Joo-Hee
2016-06-01
To assess the relationship between imaging features of pulmonary tuberculosis at computed tomography (CT) and adenosine deaminase (ADA) values via pleural fluid analysis in patients with pleural tuberculosis. This retrospective study enrolled 60 patients who underwent fluid analysis for ADA and chest CT and were diagnosed with tuberculosis by culture or polymerase chain reaction of pleural fluid and sputum. The presence of centrilobular nodules, consolidation, cavitation, and mediastinal lymphadenopathy at CT were evaluated. The relationship between ADA values and the pattern of pulmonary involvement of tuberculosis was analysed. Pulmonary involvement was seen in 42 of the 60 patients. A centrilobular nodular pattern was seen in 37 and consolidation in 22. In 17 patients, both findings were identified. A centrilobular nodular pattern was more common than consolidation or cavitary lesions. When ADA values were high, pulmonary involvement was more frequent (p=0.002). Comparing low and high ADA groups using an obtained cut-off value of 80 IU/l, the high group had more frequent pulmonary involvement (p<0.001). Patients with tuberculous pleurisy who had high ADA values had a higher probability of manifesting pulmonary tuberculosis. High ADA values may help predict contagious pleuroparenchymal tuberculosis. The most common pulmonary involvement of tuberculous pleurisy showed a centrilobular nodular pattern. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Yang, Tao; Wang, Lei; Xiong, Chang-Ming; He, Jian-Guo; Zhang, Yan; Gu, Qing; Zhao, Zhi-Hui; Ni, Xin-Hai; Fang, Wei; Liu, Zhi-Hong
2014-05-01
It is known that patients with pulmonary hypertension (PH) can have elevated F-FDG uptake in the right ventricle (RV) on PET imaging. This study was designed to assess possible relationship between FDG uptake of ventricles and the function/hemodynamics of the RV in patients with PH. Thirty-eight patients with PH underwent FDG PET imaging in both fasting and glucose-loading conditions. The standard uptake value (SUVs) corrected for partial volume effect in both RV and left ventricle (LV) were measured. The ratio of FDG uptake between RV to LV (SUVR/L) was calculated. Right heart catheterization and cardiac magnetic resonance (CMR) were performed in all patients within 1 week. The FDG uptake levels by the ventricles were compared with the result form the right heart catheterization and CMR. The SUV of RV (SUVR) and SUV of LV were significantly higher in glucose-loading condition than in fasting condition. In both fasting and glucose-loading conditions, SUVR and SUVR/L showed reverse correlation with right ventricular ejection fraction derived from CMR. In addition, in both fasting and glucose-loading conditions, SUVR and SUVR/L showed positive correlations with pulmonary vascular resistance. However, only SUVR/L in glucose-loading condition could independently predict right ventricular ejection fraction after adjusted for age, body mass index, sex, mean right atrial pressure, mean pulmonary arterial pressure, and pulmonary vascular resistance (P = 0.048). The FDG uptake of RV increases with decreased right ventricular function in patients with PH. Increased FDG uptake ratio between RV and LV might be useful to assess the right ventricular function.
Glew, R H; Kassam, H; Vander Voort, J; Agaba, P A; Harkins, M; VanderJagt, D J
2004-08-01
Children in northern Nigeria and elsewhere in the hot, arid western Sahel, are at risk of having their lung function compromised by a variety of factors, including undernutrition, environmental factors (e.g. airborne pollutants such as dust and smoke from wood fires), chronic upper-respiratory tract infections, and low socioeconomic class. We were interested in using spirometry to compare the pulmonary function of Nigerian children and adolescents aged 6-18 years who were living in urban and rural settings with the corresponding standards for African-American children. A total of 183 boys and girls in the rural village of Sabon Fobur on the Jos Plateau and another 128 boys and girls in the city of Jos were tested to determine their forced vital capacity (FVC), FVC at 1 s (FVC1), and peak expiratory flow (PEF). The nutritional status of the subjects was determined by measuring the body mass index (BMI), triceps skin-fold thickness, and mid-arm circumference, and fat-free mass (FFM) and fat mass (FM) by bioelectrical impedance analysis. According to the results of anthropometry, the subjects in Sabon Fobur and Jos were lean but generally adequately nourished. The mean FVC, FVC1 and PEF values for the rural males were 1.851,1.761, and 3.521, and for the urban males they were 1.971,1.791, and 3.471, respectively. The corresponding values for the rural females were 1.791,1.701, and 3.371, and for the urban females they were 1.761,1.671, and 3.091. These values were approximately 100 per cent of the corresponding values for African-American children. In general, strong correlations were found between each of the three lung function parameters and age, weight, height (only for the males), BMI, MAC, and FFM. These results show that: (1) the lung function of Nigerian children and adolescents living in either rural or urban areas were similar and compared favorably with African-American standards, and (2) weight was as important as height in determining pulmonary function. The inclusion of FFM as an explanatory variable did notfurther increase the accuracy of the prediction, even in a population where malnutrition may be prevalent. Therefore, we conclude that measurements of height and weight are all that are required for the assessment of lung function using spirometry in Nigerian children.
[Pulmonary decortication: value of lung function recovery].
Arsalane, A; Zidane, A; Atoini, F; Traibi, A; Ameziane, N; Kabiri, E-H
2009-10-01
Based on the experience in the thoracic surgery unit at Hôpital Militaire d'Instruction Mohammed-V in Rabat, this study analyses the indications as well as the results of pulmonary decortication. Twenty-five cases of pulmonary decortication were examined over a period of 5 years ranging from January 2002 to December 2006. The aetiology of chronic pyothorax was dominated by non tubercular causes. The clinical symptomatology mainly involved fever and dyspnoea (48% and 44% respectively). Pachypleuritis, collapse of the lung and pleural effusion account for most of the lesions found on the thoracic imaging. Surgery was indicated after failure in the medical treatment after four months on the average. The respiratory function was assessed in 20 patients three months after the intervention. The improvement in the spirometry was good in 85% of the cases (n=17), was not highly satisfactory in 10% of the cases (n=2) and a deterioration was noted in 5% of the cases (n=1). This unfavourable evolution was correlated with the tubercular aetiology and the poor state of the pulmonary parenchyma. Non tubercular causes, early diagnosis and absence of parenchymatous lesion seem to be predictive factors of good results after decortication.
Hataji, Osamu; Nishii, Yoichi; Ito, Kentaro; Sakaguchi, Tadashi; Saiki, Haruko; Suzuki, Yuta; D'Alessandro-Gabazza, Corina; Fujimoto, Hajime; Kobayashi, Tetsu; Gabazza, Esteban C.; Taguchi, Osamu
2017-01-01
Combined therapy with tiotropium and olodaterol notably improves parameters of lung function and quality of life in patients with chronic obstructive pulmonary disease (COPD) compared to mono-components; however, its effect on physical activity is unknown. The present study evaluated whether combination therapy affects daily physical performance in patients with COPD under a smart watch-based encouragement program. This was a non-blinded clinical trial with no randomization or placebo control. A total of 20 patients with COPD were enrolled in the present study. The patients carried an accelerometer for 4 weeks; they received no therapy during the first 2 weeks but they were treated with combined tiotropium and olodaterol under a smart watch-based encouragement program for the last 2 weeks. The pulmonary function test, COPD assessment test, 6-min walk distance and parameters of physical activity were significantly improved (P<0.05) by combination therapy under smart watch-based coaching compared with values prior to treatment. To the best of our knowledge, the present study for the first time provides evidence that smart watch-based coaching in combination with tiotropium and olodaterol may improve daily physical activity in chronic obstructive pulmonary disease. PMID:29104624
Hataji, Osamu; Nishii, Yoichi; Ito, Kentaro; Sakaguchi, Tadashi; Saiki, Haruko; Suzuki, Yuta; D'Alessandro-Gabazza, Corina; Fujimoto, Hajime; Kobayashi, Tetsu; Gabazza, Esteban C; Taguchi, Osamu
2017-11-01
Combined therapy with tiotropium and olodaterol notably improves parameters of lung function and quality of life in patients with chronic obstructive pulmonary disease (COPD) compared to mono-components; however, its effect on physical activity is unknown. The present study evaluated whether combination therapy affects daily physical performance in patients with COPD under a smart watch-based encouragement program. This was a non-blinded clinical trial with no randomization or placebo control. A total of 20 patients with COPD were enrolled in the present study. The patients carried an accelerometer for 4 weeks; they received no therapy during the first 2 weeks but they were treated with combined tiotropium and olodaterol under a smart watch-based encouragement program for the last 2 weeks. The pulmonary function test, COPD assessment test, 6-min walk distance and parameters of physical activity were significantly improved (P<0.05) by combination therapy under smart watch-based coaching compared with values prior to treatment. To the best of our knowledge, the present study for the first time provides evidence that smart watch-based coaching in combination with tiotropium and olodaterol may improve daily physical activity in chronic obstructive pulmonary disease.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hollinger, W.M.; Staton, G.W. Jr.; Fajman, W.A.
1985-07-01
To find a pretreatment predictor of steroid responsiveness in pulmonary sarcoidosis the authors studied 21 patients before and after steroid treatment by clinical evaluation, pulmonary function tests, bronchoalveolar lavage (BAL), gallium-67 lung scan, and serum angiotensin-converting enzyme (SACE) level. Although clinical score, forced vital capacity (FVC), BAL percent lymphocytes (% lymphs), quantitated gallium-67 lung uptake, and SACE levels all improved with therapy, only the pretreatment BAL % lymphs correlated with the improvement in FVC (r = 0.47, p less than 0.05). Pretreatment BAL % lymphs of greater than or equal to 35% predicted improvement in FVC of 10/11 patients, whereasmore » among 10 patients with BAL % lymphs less than 35%, 5 patients improved and 5 deteriorated. Clinical score, pulmonary function parameters, quantitated gallium-67 lung uptake, and SACE level used alone, in combination with BAL % lymphs or in combination with each other, did not improve this predictive value. The authors conclude that steroid therapy improves a number of clinical and laboratory parameters in sarcoidosis, but only the pretreatment BAL % lymphs are useful in predicting therapeutic responsiveness.« less
Michelakis, Evangelos D; Tymchak, Wayne; Noga, Michelle; Webster, Linda; Wu, Xi-Chen; Lien, Dale; Wang, Shao-Hua; Modry, Dennis; Archer, Stephen L
2003-10-28
The prognosis and functional capacity of patients with pulmonary arterial hypertension (PAH) is poor, and there is a need for safe, effective, inexpensive oral treatments. A single dose of sildenafil, an oral phosphodiesterase type-5 (PD-5) inhibitor, is an effective and selective pulmonary vasodilator in PAH. However, the long-term effects of PD-5 inhibition and its mechanism of action in human pulmonary arteries (PAs) are unknown. We hypothesized that 3 months of sildenafil (50 mg orally every 8 hours) added to standard treatment would be safe and improve functional capacity and hemodynamics in PAH patients. We studied 5 consecutive patients (4 with primary pulmonary hypertension, 1 with Eisenmenger's syndrome; New York Heart Association class II to III). Functional class improved by > or =1 class in all patients. Pretreatment versus posttreatment values (mean+/-SEM) were as follows: 6-minute walk, 376+/-30 versus 504+/-27 m, P<0.0001; mean PA pressure, 70+/-3 versus 52+/-3 mm Hg, P<0.007; pulmonary vascular resistance index 1702+/-151 versus 996+/-92 dyne x s x cm(-5) x m(-2), P<0.006. The systemic arterial pressure was unchanged, and no adverse effects occurred. Sildenafil also reduced right ventricular mass measured by MRI. In 7 human PAs (6 cardiac transplant donors and 1 patient with PAH on autopsy), we showed that PD-5 is present in PA smooth muscle cells and that sildenafil causes relaxation by activating large-conductance, calcium-activated potassium channels. This small pilot study suggests that long-term sildenafil therapy might be a safe and effective treatment for PAH. At a monthly cost of 492 dollars Canadian, sildenafil is more affordable than most approved PAH therapies. A large multicenter trial is indicated to directly compare sildenafil with existing PAH treatments.
Babashani, M; Iliyasu, Z; Ukoli, C O
2008-01-01
The industrial process of detergent production could be deleterious to lung function. This study describes respiratory symptoms and ventilatory function impairment among detergent workers in Jos, Northern Nigeria. Two hundred detergent plant workers and controls were studied for the presence of respiratory symptoms and ventilatory function impairment using the MRC questionnaire and Spirometry. A significantly higher proportion of exposed detergent workers 178 (87.0%) reported respiratory symptoms compared to 52 (26.0%) controls [OR=23; 95% CI=12.9-41.3] (P<0.001). Commonest symptoms include rhinitis (57.5% versus 11.0%) and cough (48.5% versus 15%). Symptoms were most prevalent in the packaging section. FEV1, FVC and PEFR were significantly reduced among exposed detergent workers. Similarly, the predicted values of PEFR, FVC and FEV1, were significantly reduced among smokers (P<0. 001). Respiratory symptoms are highly prevalent among detergent workers. This was associated with impaired pulmonary function. Protective equipment and periodic lung function tests could reduce these effects.
[Experts consensus on the management of the right heart function in critically ill patients].
Wang, X T; Liu, D W; Zhang, H M; Long, Y; Guan, X D; Qiu, H B; Yu, K J; Yan, J; Zhao, H; Tang, Y Q; Ding, X; Ma, X C; Du, W; Kang, Y; Tang, B; Ai, Y H; He, H W; Chen, D C; Chen, H; Chai, W Z; Zhou, X; Cui, N; Wang, H; Rui, X; Hu, Z J; Li, J G; Xu, Y; Yang, Y; Ouyan, B; Lin, H Y; Li, Y M; Wan, X Y; Yang, R L; Qin, Y Z; Chao, Y G; Xie, Z Y; Sun, R H; He, Z Y; Wang, D F; Huang, Q Q; Jiang, D P; Cao, X Y; Yu, R G; Wang, X; Chen, X K; Wu, J F; Zhang, L N; Yin, M G; Liu, L X; Li, S W; Chen, Z J; Luo, Z
2017-12-01
To establish the experts consensus on the right heart function management in critically ill patients. The panel of consensus was composed of 30 experts in critical care medicine who are all members of Critical Hemodynamic Therapy Collaboration Group (CHTC Group). Each statement was assessed based on the GRADE (Grading of Recommendations Assessment, Development, and Evaluation) principle. Then the Delphi method was adopted by 52 experts to reassess all the statements. (1) Right heart function is prone to be affected in critically illness, which will result in a auto-exaggerated vicious cycle. (2) Right heart function management is a key step of the hemodynamic therapy in critically ill patients. (3) Fluid resuscitation means the process of fluid therapy through rapid adjustment of intravascular volume aiming to improve tissue perfusion. Reversed fluid resuscitation means reducing volume. (4) The right ventricle afterload should be taken into consideration when using stroke volume variation (SVV) or pulse pressure variation (PPV) to assess fluid responsiveness.(5)Volume overload alone could lead to septal displacement and damage the diastolic function of the left ventricle. (6) The Starling curve of the right ventricle is not the same as the one applied to the left ventricle,the judgement of the different states for the right ventricle is the key of volume management. (7) The alteration of right heart function has its own characteristics, volume assessment and adjustment is an important part of the treatment of right ventricular dysfunction (8) Right ventricular enlargement is the prerequisite for increased cardiac output during reversed fluid resuscitation; Nonetheless, right heart enlargement does not mandate reversed fluid resuscitation.(9)Increased pulmonary vascular resistance induced by a variety of factors could affect right heart function by obstructing the blood flow. (10) When pulmonary hypertension was detected in clinical scenario, the differentiation of critical care-related pulmonary hypertension should be a priority. (11) Attention should be paid to the change of right heart function before and after implementation of mechanical ventilation and adjustment of ventilator parameter. (12) The pulmonary arterial pressure should be monitored timingly when dealing with critical care-related pulmonary hypertension accompanied with circulatory failure.(13) The elevation of pulmonary aterial pressure should be taken into account in critical patients with acute right heart dysfunction. (14) Prone position ventilation is an important measure to reduce pulmonary vascular resistance when treating acute respiratory distress syndrome patients accompanied with acute cor pulmonale. (15) Attention should be paid to right ventricle-pulmonary artery coupling during the management of right heart function. (16) Right ventricular diastolic function is more prone to be affected in critically ill patients, the application of critical ultrasound is more conducive to quantitative assessment of right ventricular diastolic function. (17) As one of the parameters to assess the filling pressure of right heart, central venous pressure can be used to assess right heart diastolic function. (18). The early and prominent manifestation of non-focal cardiac tamponade is right ventricular diastolic involvement, the elevated right atrial pressure should be noticed. (19) The effect of increased intrathoracic pressure on right heart diastolic function should be valued. (20) Ttricuspid annular plane systolic excursion (TAPSE) is an important parameter that reflects right ventricular systolic function, and it is recommended as a general indicator of critically ill patient. (21) Circulation management with right heart protection as the core strategy is the key point of the treatment of acute respiratory distress syndrome. (22) Right heart function involvement after cardiac surgery is very common and should be highly valued. (23) Right ventricular dysfunction should not be considered as a routine excuse for maintaining higher central venous pressure. (24) When left ventricular dilation, attention should be paid to the effect of left ventricle on right ventricular diastolic function. (25) The impact of left ventricular function should be excluded when the contractility of the right ventricle is decreased. (26) When the right heart load increases acutely, the shunt between the left and right heart should be monitored. (27) Attention should be paid to the increase of central venous pressure caused by right ventricular dysfunction and its influence on microcirculation blood flow. (28) When the vasoactive drugs was used to reduce the pressure of pulmonary circulation, different effects on pulmonary and systemic circulation should be evaluated. (29) Right atrial pressure is an important factor affecting venous return. Attention should be paid to the influence of the pressure composition of the right atrium on the venous return. (30) Attention should be paid to the role of the right ventricle in the acute pulmonary edema. (31) Monitoring the difference between the mean systemic filling pressure and the right atrial pressure is helpful to determine whether the infusion increases the venous return. (32) Venous return resistance is often considered to be a insignificant factor that affects venous return, but attention should be paid to the effect of the specific pathophysiological status, such as intrathoracic hypertension, intra-abdominal hypertension and so on. Consensus can promote right heart function management in critically ill patients, optimize hemodynamic therapy, and even affect prognosis.
Jo, Bum Seak; Myong, Jun Pyo; Rhee, Chin Kook; Yoon, Hyoung Kyu; Koo, Jung Wan; Kim, Hyoung Ryoul
2018-01-15
The present study aimed to update the prediction equations for spirometry and their lower limits of normal (LLN) by using the lambda, mu, sigma (LMS) method and to compare the outcomes with the values of previous spirometric reference equations. Spirometric data of 10,249 healthy non-smokers (8,776 females) were extracted from the fourth and fifth versions of the Korea National Health and Nutrition Examination Survey (KNHANES IV, 2007-2009; V, 2010-2012). Reference equations were derived using the LMS method which allows modeling skewness (lambda [L]), mean (mu [M]), and coefficient of variation (sigma [S]). The outcome equations were compared with previous reference values. Prediction equations were presented in the following form: predicted value = e{a + b × ln(height) + c × ln(age) + M - spline}. The new predicted values for spirometry and their LLN derived using the LMS method were shown to more accurately reflect transitions in pulmonary function in young adults than previous prediction equations derived using conventional regression analysis in 2013. There were partial discrepancies between the new reference values and the reference values from the Global Lung Function Initiative in 2012. The results should be interpreted with caution for young adults and elderly males, particularly in terms of the LLN for forced expiratory volume in one second/forced vital capacity in elderly males. Serial spirometry follow-up, together with correlations with other clinical findings, should be emphasized in evaluating the pulmonary function of individuals. Future studies are needed to improve the accuracy of reference data and to develop continuous reference values for spirometry across all ages. © 2018 The Korean Academy of Medical Sciences.
Left atrial strain predicts hemodynamic parameters in cardiovascular patients.
Hewing, Bernd; Theres, Lena; Spethmann, Sebastian; Stangl, Karl; Dreger, Henryk; Knebel, Fabian
2017-08-01
We aimed to evaluate the predictive value of left atrial (LA) reservoir, conduit, and contractile function parameters as assessed by speckle tracking echocardiography (STE) for invasively measured hemodynamic parameters in a patient cohort with myocardial and valvular diseases. Sixty-nine patients undergoing invasive hemodynamic assessment were enrolled into the study. Invasive hemodynamic parameters were obtained by left and right heart catheterization. Transthoracic echocardiography assessment of LA reservoir, conduit, and contractile function was performed by STE. Forty-nine patients had sinus rhythm (SR) and 20 patients had permanent atrial fibrillation (AF). AF patients had significantly reduced LA reservoir function compared to SR patients. In patients with SR, LA reservoir, conduit, and contractile function inversely correlated with pulmonary capillary wedge pressure (PCWP), left ventricular end-diastolic pressure, and mean pulmonary artery pressure (PAP), and showed a moderate association with cardiac index. In AF patients, there were no significant correlations between LA reservoir function and invasively obtained hemodynamic parameters. In SR patients, LA contractile function with a cutoff value of 16.0% had the highest diagnostic accuracy (area under the curve, AUC: 0.895) to predict PCWP ≥18 mm Hg compared to the weaker diagnostic accuracy of average E/E' ratio with an AUC of 0.786 at a cutoff value of 14.3. In multivariate analysis, LA contractile function remained significantly associated with PCWP ≥18 mm Hg. In a cohort of patients with a broad spectrum of cardiovascular diseases LA strain shows a valuable prediction of hemodynamic parameters, specifically LV filling pressures, in the presence of SR. © 2017, Wiley Periodicals, Inc.
van Gestel, A J R; Clarenbach, C F; Stöwhas, A C; Teschler, S; Russi, E W; Teschler, H; Kohler, M
2012-01-01
Previous studies with small sample sizes reported contradicting findings as to whether pulmonary function tests can predict exercise-induced oxygen desaturation (EID). To evaluate whether forced expiratory volume in one second (FEV(1)), resting oxygen saturation (SpO(2)) and diffusion capacity for carbon monoxide (DLCO) are predictors of EID in chronic obstructive pulmonary disease (COPD). We measured FEV(1), DLCO, SpO(2) at rest and during a 6-min walking test as well as physical activity by an accelerometer. A drop in SpO(2) of >4 to <90% was defined as EID. To evaluate associations between measures of lung function and EID univariate and multivariate analyses were used and positive/negative predictive values were calculated. Receiver operating characteristic curve analysis was performed to determine the most useful threshold in order to predict/exclude EID. We included 154 patients with COPD (87 females). The mean FEV(1) was 43.0% (19.2) predicted and the prevalence of EID was 61.7%. The only independent predictor of EID was FEV(1) and the optimal cutoff value of FEV(1) was at 50% predicted (area under ROC curve, 0.85; p < 0.001). The positive predictive value of a threshold of FEV(1) <50% was 0.83 with a likelihood ratio of 3.03 and the negative predicting value of a threshold of FEV(1) ≥80% was 1.0. The severity of EID was correlated with daily physical activity (r = -0.31, p = 0.008). EID is highly prevalent among patients with COPD and can be predicted by FEV(1). EID seems to be associated with impaired daily physical activity which supports its clinical importance. Copyright © 2012 S. Karger AG, Basel.
Rehman, Michaela B; Garcia, Rodrigue; Christiaens, Luc; Larrieu-Ardilouze, Elisa; Howard, Luke S; Nihoyannopoulos, Petros
2018-04-15
Right ventricular function is the major determinant of morbidity and mortality in pulmonary arterial hypertension (PAH). The ESC risk assessment strategy for PAH is based on clinical status, exercise testing, NTproBNP, imaging and haemodynamics but does not include right ventricular function. Our aims were to test the power of resting echocardiographic measurements to classify PAH patients according to ESC exercise testing risk stratification cut-offs and to determine if the classification power of echocardiographic parameters varied in chronic thrombo-embolic pulmonary hypertension (CTEPH). We prospectively and consecutively recruited 46 PAH patients and 42 CTEPH patients referred for cardio-pulmonary exercise testing and comprehensive transthoracic echocardiography. Exercise testing parameters analyzed were peak oxygen consumption, percentage of predicted maximal oxygen consumption and the slope of ventilation against carbon dioxide production. Receiver operator characteristic curves were used to determine the optimal diagnostic cut-off values of echocardiographic parameters for classifying the patients in intermediate or high risk category according to exercise testing. Measurements of right ventricular systolic function were the best for classifying in PAH (area under the curve 0.815 to 0.935). Measurements of right ventricular pressure overload (0.810 to 0.909) were optimal for classifying according to exercise testing in CTEPH. Measurements of left ventricular function were of no use in either group. Measurements of right ventricular systolic function can classify according to exercise testing risk stratification cut-offs in PAH. However, this is not the case in CTEPH where pressure overload, rather than right ventricular function seems to be linked to exercise performance. Copyright © 2018 Elsevier B.V. All rights reserved.
Study of adrenal function in patients with tuberculosis.
Sarin, Bipan Chander; Sibia, Keerat; Kukreja, Sahiba
2018-07-01
Although subclinical adrenal insufficiency has been documented in tuberculosis but it has been neglected in mainstream management of TB due to inconclusive data on its prevalence in TB. The fact that adrenal insufficiency may result not only in poor general condition of the patient but also sudden death due to adrenal crisis, makes it all the more important to address this issue seriously. In this non-randomized interventional study comprising of 100 cases of TB, our aim was to assess the adreno-cortical functions in patients with pulmonary TB (50 cases) and extra-pulmonary TB (50 cases) in an attempt to determine if there is any compromise of adrenal function. In this study, 100 cases of active TB were investigated for adrenal insufficiency by measuring morning fasting basal serum cortisol levels, followed by low dose ACTH stimulation test using 1μg synacthen (synthetic ACTH analog). The post-stimulation serum cortisol levels were estimated. Basal serum cortisol levels<220nmol/L or post-stimulation test serum cortisol level increment<200nmol/L or post-stimulation serum cortisol levels<500nmol/L were suggestive of adrenal insufficiency. Basal serum cortisol level was low in 16% cases and after low dose ACTH stimulation test, cortisol response was subnormal in 76% cases. Incidence of adrenal insufficiency in pulmonary TB (74%) and extra-pulmonary TB (78%) were comparable. The number of females having adrenal insufficiency in both the groups was higher than the males (67.3% males and 83.3% females) but the difference was statistically significant only in extra-pulmonary TB group (p=0.011). On analysing the data, the sensitivity of basal serum cortisol level estimation in diagnosing adrenal insufficiency was observed to be 21.05% and its specificity was 100%. Positive predictive value was 100% and negative predictive value was 28.57%. Diagnostic accuracy of basal serum cortisol level estimation was observed to be 40%. The incidence of subclinical adrenal insufficiency in TB cases attending chest department at a tertiary care hospital was significantly high but comparable in both pulmonary and extra-pulmonary type of TB. Females in general and particularly those with extra-pulmonary TB were observed to be at increased risk of adrenal insufficiency. The low dose ACTH stimulation test was able to identify cases with adrenal insufficiency which had normal basal serum cortisol levels. Screening all TB cases for adrenal insufficiency by measuring both morning basal serum cortisol levels and low dose ACTH stimulation test can help identify cases at risk of fatal adrenal crisis and institute timely management, thus improving disease prognosis. Copyright © 2017 Tuberculosis Association of India. Published by Elsevier B.V. All rights reserved.
Obad, Ante; Palada, Ivan; Valic, Zoran; Ivančev, Vladimir; Baković, Darija; Wisløff, Ulrik; Brubakk, Alf O; Dujić, Željko
2007-01-01
Diving-induced acute alterations in cardiovascular function such as arterial endothelial dysfunction, increased pulmonary artery pressure (PAP) and reduced heart function have been recently reported. We tested the effects of acute antioxidants on arterial endothelial function, PAP and heart function before and after a field dive. Vitamins C (2 g) and E (400 IU) were given to subjects 2 h before a second dive (protocol 1) and in a placebo-controlled crossover study design (protocol 2). Seven experienced divers performed open sea dives to 30 msw with standard decompression in a non-randomized protocol, and six of them participated in a randomized trial. Before and after the dives ventricular volumes and function and pulmonary and brachial artery function were assessed by ultrasound. The control dive resulted in a significant reduction in flow-mediated dilatation (FMD) and heart function with increased mean PAP. Twenty-four hours after the control dive FMD was still reduced 37% below baseline (8.1 versus 5.1%, P = 0.005), while right ventricle ejection fraction (RV-EF), left ventricle EF and endocardial fractional shortening were reduced much less (∼2–3%). At the same time RV end-systolic volume was increased by 9% and mean PAP by 5%. Acute antioxidants significantly attenuated only the reduction in FMD post-dive (P < 0.001), while changes in pulmonary artery and heart function were unaffected by antioxidant ingestion. These findings were confirmed by repeating the experiments in a randomized study design. FMD returned to baseline values 72 h after the dive with pre-dive placebo, whereas for most cardiovascular parameters this occurred earlier (24–48 h). Right ventricular dysfunction and increased PAP lasted longer. Acute antioxidants attenuated arterial endothelial dysfunction after diving, while reduction in heart and pulmonary artery function were unchanged. Cardiovascular changes after diving are not fully reversed up to 3 days after a dive, suggesting longer lasting negative effects. PMID:17110413
Obad, Ante; Palada, Ivan; Valic, Zoran; Ivancev, Vladimir; Baković, Darija; Wisløff, Ulrik; Brubakk, Alf O; Dujić, Zeljko
2007-02-01
Diving-induced acute alterations in cardiovascular function such as arterial endothelial dysfunction, increased pulmonary artery pressure (PAP) and reduced heart function have been recently reported. We tested the effects of acute antioxidants on arterial endothelial function, PAP and heart function before and after a field dive. Vitamins C (2 g) and E (400 IU) were given to subjects 2 h before a second dive (protocol 1) and in a placebo-controlled crossover study design (protocol 2). Seven experienced divers performed open sea dives to 30 msw with standard decompression in a non-randomized protocol, and six of them participated in a randomized trial. Before and after the dives ventricular volumes and function and pulmonary and brachial artery function were assessed by ultrasound. The control dive resulted in a significant reduction in flow-mediated dilatation (FMD) and heart function with increased mean PAP. Twenty-four hours after the control dive FMD was still reduced 37% below baseline (8.1 versus 5.1%, P = 0.005), while right ventricle ejection fraction (RV-EF), left ventricle EF and endocardial fractional shortening were reduced much less (approximately 2-3%). At the same time RV end-systolic volume was increased by 9% and mean PAP by 5%. Acute antioxidants significantly attenuated only the reduction in FMD post-dive (P < 0.001), while changes in pulmonary artery and heart function were unaffected by antioxidant ingestion. These findings were confirmed by repeating the experiments in a randomized study design. FMD returned to baseline values 72 h after the dive with pre-dive placebo, whereas for most cardiovascular parameters this occurred earlier (24-48 h). Right ventricular dysfunction and increased PAP lasted longer. Acute antioxidants attenuated arterial endothelial dysfunction after diving, while reduction in heart and pulmonary artery function were unchanged. Cardiovascular changes after diving are not fully reversed up to 3 days after a dive, suggesting longer lasting negative effects.
Badagliacca, Roberto; Poscia, Roberto; Pezzuto, Beatrice; Papa, Silvia; Gambardella, Cristina; Francone, Marco; Mezzapesa, Mario; Nocioni, Martina; Nona, Alfred; Rosati, Riccardo; Sciomer, Susanna; Fedele, Francesco; Dario Vizza, Carmine
2015-03-01
Right ventricular (RV) dyssynchrony has been described in pulmonary arterial hypertension (PAH), but no evidence is available on its morphologic determinants and its effect on systolic function. The aim of this study was to evaluate the morphologic determinants of RV dyssynchrony by echocardiographic and cardiac magnetic resonance imaging and its effect on systolic function. In 60 consecutive idiopathic PAH (IPAH) patients with narrow QRS, RV dyssynchrony was evaluated by 2D speckle-tracking echocardiography, calculating the standard deviation of the times to peak systolic strain for the four mid-basal RV segments (RV-SD4). Patients were grouped by the median value of RV-SD4 (19 milliseconds) and compared for RV remodeling and systolic function parameters, WHO class, pulmonary hemodynamics and 6-minute walk test (6MWT). Despite similar pulmonary vascular resistance and mean pulmonary arterial pressure, patients with RV-SD4 at >19 milliseconds had advanced WHO class and worse 6MWT, RV hemodynamics, RV remodeling and systolic function parameters compared with patients at ≤19 milliseconds. The morphologic determinants of RV dyssynchrony resulted RV end-diastolic area, LV diastolic eccentricity index and RV mass volume ratio (r = 0.69, r(2) = 0.47, p < 0.0001). Finally, we found a significant inverse correlation between RV mid-basal segments post-systolic shortening time and cardiac index (r = -0.64, r(2) = 0.41, p = 0.001), accounting for the significant correlation between RV-SD4 and cardiac index (r = 0.57, r(2) = 0.32, p = 0.003). In IPAH with narrow QRS, RV dyssynchrony is associated with RV dilation and eccentric hypertrophy pattern, suggesting a role of segmental wall stress heterogeneity as the major determinant of mechanical delay. Post-systolic shortening, as inefficient contraction, contributes to pump dysfunction. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Saito, Hajime; Hatakeyama, Kazutoshi; Konno, Hayato; Matsunaga, Toshiki; Shimada, Yoichi; Minamiya, Yoshihiro
2017-09-01
Given the extent of the surgical indications for pulmonary lobectomy in breathless patients, preoperative care and evaluation of pulmonary function are increasingly necessary. The aim of this study was to assess the contribution of preoperative pulmonary rehabilitation (PR) for reducing the incidence of postoperative pulmonary complications in non-small cell lung cancer (NSCLC) patients with chronic obstructive pulmonary disease (COPD). The records of 116 patients with COPD, including 51 patients who received PR, were retrospectively analyzed. Pulmonary function testing, including slow vital capacity (VC) and forced expiratory volume in one second (FEV 1 ), was obtained preoperatively, after PR, and at one and six months postoperatively. The recovery rate of postoperative pulmonary function was standardized for functional loss associated with the different resected lung volumes. Propensity score analysis generated matched pairs of 31 patients divided into PR and non-PR groups. The PR period was 18.7 ± 12.7 days in COPD patients. Preoperative pulmonary function was significantly improved after PR (VC 5.3%, FEV 1 5.5%; P < 0.05). The FEV 1 recovery rate one month after surgery was significantly better in the PR (101.6%; P < 0.001) than in the non-PR group (93.9%). In logistic regression analysis, predicted postoperative FEV 1 , predicted postoperative %FEV 1 , and PR were independent factors related to postoperative pulmonary complications after pulmonary lobectomy (odds ratio 18.9, 16.1, and 13.9, respectively; P < 0.05). PR improved the recovery rate of pulmonary function after lobectomy in the early period, and may decrease postoperative pulmonary complications. © 2017 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.
Pulmonary function of children with acute leukemia in maintenance phase of chemotherapy☆
de Macêdo, Thalita Medeiros Fernandes; Campos, Tania Fernandes; Mendes, Raquel Emanuele de França; França, Danielle Corrêa; Chaves, Gabriela Suéllen da Silva; de Mendonça, Karla Morganna Pereira Pinto
2014-01-01
OBJECTIVE: The aim of this study was to assess the pulmonary function of children with acute leukemia. METHODS: Cross-sectional observational analytical study that enrolled 34 children divided into groups A (17 with acute leukemia in the maintenance phase of chemotherapy) and B (17 healthy children). The groups were matched for sex, age and height. Spirometry was measured using a spirometer Microloop Viasys(r) in accordance with American Thoracic Society and European Respiratory Society guidelines. Maximal respiratory pressures were measured with an MVD300 digital manometer (Globalmed(r)). Maximal inspiratory pressures and maximal expiratory pressures were measured from residual volume and total lung capacity, respectively. RESULTS: Group A showed a significant decrease in maximal inspiratory pressures when compared to group B. No significant difference was found between the spirometric values of the two groups, nor was there any difference between maximal inspiratory pressure and maximal expiratory pressure values in group A compared to the lower limit values proposed as reference. CONCLUSION: Children with acute leukemia, myeloid or lymphoid, during the maintenance phase of chemotherapy exhibited unchanged spirometric variables and maximal expiratory pressure; However, there was a decrease in inspiratory muscle strength. PMID:25510995
Farias, Catharinne C; Resqueti, Vanessa; Dias, Fernando A L; Borghi-Silva, Audrey; Arena, Ross; Fregonezi, Guilherme A F
2014-01-01
The current study evaluated the costs and benefits of a simple aerobic walking program for patients with chronic obstructive pulmonary disease (COPD). This was a blinded randomized controlled clinical trial that recruited 72 patients diagnosed with COPD, 40 of whom were included in the study and divided into two groups [control group (CG) and pulmonary rehabilitation group (GPR)]. We assessed pulmonary function, distance covered during the 6-minute walk test (6MWT), respiratory and peripheral muscle strength, health-related quality of life (HRQOL), body composition, and level of activities of daily living (ADLs) before and after an 8-week walking program. The financial costs were calculated according to the pricing table of the Brazilian Unified Health System (SUS). Only 34 of the 40 patients remained in the final sample; 16 in the CG and 18 in the GPR (FEV1: 50.9 ± 14% predicted and FEV1: 56 ± 0.5% predicted, respectively). The intervention group exhibited improvements in the 6MWT, sensation of dyspnea and fatigue, work performed, BODE index (p<0.01), HRQOL, ADL level (p<0.001), and lower limb strength (p<0.05). The final mean cost per patient for the GPR was R$ 148.75 (~US$ 75.00) and no patient significantly exceeded this value. However, 2 patients in the CG did exceed this value, incurring a cost of R$ 689.15 (~US$ 345.00). Aerobic walking demonstrated significant clinical benefits in a cost-efficient manner in patients with COPD.
Function of the Respiratory System in Elderly Patients After Aortic Valve Replacement.
Stoliński, Jarosław; Plicner, Dariusz; Gawęda, Bogusław; Musiał, Robert; Fijorek, Kamil; Wąsowicz, Marcin; Andres, Janusz; Kapelak, Bogusław
2016-10-01
To compare the function of the respiratory system after aortic valve replacement through median sternotomy (AVR) or the minimally invasive right anterior minithoracotomy (RAT-AVR) approach among elderly (aged≥75 years) patients. Observational cohort study. University hospital. The study included 65 elderly patients scheduled for RAT-AVR and 82 for standard AVR. Pulmonary function tests (PFT) were performed preoperatively, 1 week, 1 month, and 3 months after surgery. In addition, respiratory complications were analyzed. Respiratory complications occurred in 12.3% of patients in the RAT-AVR group and 18.3% of patients in the AVR group (p = 0.445). Mechanical ventilation time in the intensive care unit was 7.7±3.6 hours for RAT-AVR patients and 9.7±5.4 hours for AVR patients (p = 0.003). Most PFT were worse in the AVR group than in the RAT-AVR group when performed 1 week after surgery. After 1 month, forced expiratory volume in the first second, vital capacity, and total lung capacity differed significantly in favor of the RAT-AVR group (p = 0.002, p<0.001, and p = 0.001, respectively). After 3 months, the PFT parameters still had not returned to preoperative values, but the differences were no longer significant between the RAT-AVR and AVR groups. The multivariable median regression analysis demonstrated that RAT-AVR surgery was a key factor in a patient's higher postoperative PFT parameter values. RAT-AVR surgery resulted in shorter postoperative mechanical ventilation time and improved the recovery of pulmonary function in elderly patients, but it did not reduce the incidence of pulmonary complications when compared with surgery performed through a median sternotomy. Copyright © 2016 Elsevier Inc. All rights reserved.
Association Between Severe Vitamin D Deficiency, Lung Function and Asthma Control.
Beyhan-Sagmen, Seda; Baykan, Ozgur; Balcan, Baran; Ceyhan, Berrin
2017-04-01
To examine the relationship between severe vitamin D deficiency, asthma control, and pulmonary function in Turkish adults with asthma. One hundred six asthmatic patients underwent pulmonary function tests skin prick test, peripheral blood eosinophil counts, IgE, body mass index and vitamin D levels were determined. Patients were divided into 2 subgroups according to vitamin D levels (vitamin D level<10ng/ml and vitamin D level≥10 ng/ml). Asthma control tests were performed. The mean age of subgroup i (vitamin D level<10) was 37±10 and the mean age of subgroup ii (vitamin D level≥10ng/ml) was 34±8. Sixty-six percent of patients had severe vitamin D deficiency (vitamin D level<10 ng/ml). There was a significant trend towards lower absolute FEV 1 (L) values in patients with lower vitamin D levels (P=.001). Asthma control test scores were significantly low in the severe deficiency group than the other group (P=.02). There were a greater number of patients with uncontrolled asthma (asthma control test scores<20) in the severe vitamin D deficiency group (P=.040). Patients with severe vitamin D deficiency had a higher usage of inhaled corticosteroids than the group without severe vitamin D deficiency (P=.015). There was a significant trend towards lower absolute FEV 1 (L) (P=.005, r=.272) values in patients with lower vitamin D levels. Vitamin D levels were inversely related with body mass index (P=.046). The incidence of severe vitamin D deficiency was high in adult Turkish asthmatics. In addition, lower vitamin D levels were associated with poor asthma control and decreased pulmonary function. Copyright © 2016 SEPAR. Publicado por Elsevier España, S.L.U. All rights reserved.
Vitarelli, Antonio; Barillà, Francesco; Capotosto, Lidia; D'Angeli, Ilaria; Truscelli, Giovanni; De Maio, Melissa; Ashurov, Rasul
2014-03-01
The aim of this study was to assess changes in right ventricular (RV) parameters determined by three-dimensional (3D) echocardiography and speckle-tracking echocardiography in patients with acute pulmonary embolism and RV dysfunction without systemic hypotension (submassive pulmonary embolism). Sixty-six patients were prospectively studied at the onset of the acute episode and after median follow-up periods of 30 days and 6 months. Sixty-six controls were selected. RV fractional area change, tricuspid annular plane systolic excursion, and myocardial performance index were determined. RV systolic pressure was assessed using continuous-wave Doppler echocardiography. Three-dimensional RV ejection fraction (RVEF) was calculated. Two-dimensional peak systolic RV longitudinal strain (RVLS) was measured in the basal free wall, mid free wall (MFW), and apical free wall and the septum. Tricuspid annular plane systolic excursion and fractional area change were smaller and myocardial performance index was larger compared with controls (P < .05). Global RVLS (P < .05), MFW RVLS (P < .001), and 3D RVEF (P < .001) were lower in patients with pulmonary embolism than in controls. There was earlier reversal of MFW RVLS values on 30-day follow-up and longer reversal of 3D RVEF and RV systolic pressure values at 6-month follow-up. Receiver operating characteristic curve analysis showed that changes in 3D RVEF and MFW RVLS were the most sensitive predictors of adverse events. By multivariate analysis, RV systolic pressure (P = .007), MFW RVLS (P = .002), and 3D RVEF (P = .001) were independently associated with adverse outcomes. Acute submassive pulmonary embolism has a significant impact on RV function as assessed by 3D echocardiography and speckle-tracking echocardiography. Decreases in MFW RVLS and 3D RVEF may persist during short-term and long-term follow-up and correlate with unfavorable outcomes. Copyright © 2014 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.
Liu, Tianhao; Yang, Zhongshan; Zhang, Xiaomei; Han, Niping; Yuan, Jiali; Cheng, Yu
2017-12-01
This study aims to explore the effect of FMT on regulations of dysbacteriosis of pulmonary and intestinal flora in rats with 16S rDNA sequencing technology. A total of 27 SPF rats (3-4 weeks old) were randomly divided into three groups: normal control group (K), model control group (MX), and fecal microbiota transplantation group (FMT); each group contained nine rats. The OTU values of the pulmonary and intestinal flora of the MX group decreased significantly compared with the normal control group. After FMT, the OTU value of pulmonary flora increased, while the value of OTU in intestinal flora declined. At the phylum level, FMT down-regulated Proteobacteria , Firmicutes , and Bacteroidetes in the pulmonary flora. At the genus level, FMT down-regulated Pseudomonas , Sphingobium , Lactobacillus , Rhizobium , and Acinetobacter , thus maintaining the balance of the pulmonary flora. Moreover, FMT could change the structure and diversity of the pulmonary and intestinal flora by positively regulating the pulmonary flora and negatively regulating intestinal flora. This study may provide a scientific basis for FMT treatment of respiratory diseases.
Pan, M M; Zhang, H S; Sun, T Y
2017-05-30
Objective: To evaluate the value of forced expiratory volume in 6 seconds (FEV(6)) in the evaluation of pulmonary function in Chinese elderly males. Methods: Pulmonary function tests of elderly who had received regular physical examination in Beijing Hospital from July 2003 to April 2015 were analyzed on subjects with the following characteristics: aged 60 years or older, completion of bronchial dilation test and able to exhale for at least six seconds. The included subjects were divided into 2 groups: 60-<80 years group and ≥80 years group. The association of FEV(6) with forced vital capacity (FVC), FEV(1)/FEV(6) with FEV(1)/FVC, the diagnostic efficiency and influencing factor of FEV(6) and FEV(1)/FEV(6) were analyzed; the value of FEV(6) in the evaluation of pulmonary function in the study population was evaluated. Results: A total of 475 elderly men aged 60 years or older were enrolled, with a mean age of (77.13±9.53) years. Totally there were 269 subjects in 60-<80 years group, which accounted for 56.6%; 206 subjects were in ≥80 years group, which accounted for 43.4%. There were 292 subjects with irreversible airflow obstruction, accounting for 61.5%. In all the included subjects, FEV(6) was significantly correlated with FVC and post-bronchodilator FEV(1)/FEV(6) was significantly correlated with post-bronchodilator FEV(1)/FVC( r =0.971, 0.978; both P <0.001), which were similar in 60-<80 years group and ≥80 years group ( r =0.967, 0.974 and r =0.955, 0.967; all P <0.001). FEV(1)/FEV(6) showed excellent accuracy in diagnosing airflow obstruction[area under curve (AUC)=0.990(95% CI: 0.983-0.996); P <0.001]. Using FEV(1)/FVC<0.70 as a reference, FEV(1)/FEV(6)<0.73 had the best sensitivity (0.952) and specificity (0.945), and there was excellent agreement between the two diagnostic cutoffs (κ=0.891; P <0.001). When difference between before and after bronchial dilation test was analyzed, no correlation was observed between FEV(6) improvement and the improvement of forced expiratory time ( r =0.089; P =0.053), but FVC improvement was significantly correlated with the improvement of forced expiratory time ( r =0.460; P <0.001). Similar results were also found in subjects with irreversible airflow obstruction. Subjects with FEV(1)/FEV(6)≥0.70 and FEV(1)/FVC<0.70 were categorized as pulmonary function middle group, a total of 73 cases, which included 20 cases ≥80 years old. The proportion of middle group among ≥80 years group was significantly less than that of the 60-<80 years group (χ(2)=8.958; P =0.003). In pulmonary function middle group, FEV(1)/FEV(6) or FEV(1)/FVC had no correlation with inspiratory capacity or residual volume/total lung capacity (all P >0.05). Conclusions: FEV(6) and FEV(1)/FEV(6) are strongly correlated with FVC and FEV(1)/FVC, and there is excellent agreement between FEV(1)/FEV(6) and FEV(1)/FVC. FEV(6) is simple, easy to operate and with less influencing factors, which can be used as a valid alternative for FVC in diagnosing airflow obstruction in elderly males.
Rest and exercise echocardiography for early detection of pulmonary hypertension.
Kusunose, Kenya; Yamada, Hirotsugu
2016-03-01
Early detection of pulmonary hypertension (PH) is essential to ensure that patients receive timely and appropriate treatment for this progressive disease. Rest and exercise echocardiography has been used to screen patients in an attempt to identify early stage PH. However, current PH guidelines recommend against exercise tests because of the lack of evidence. We reviewed previous studies to discuss the current standpoint concerning rest and exercise echocardiography in PH. Around 20 exercise echocardiography studies were included to assess the cutoff value for exercise-induced pulmonary hypertension (EIPH). Approximately 40 exercise echocardiography studies were also included to evaluate the pulmonary artery pressure-flow relationship as assessed by the slope of the mean pulmonary artery pressure and cardiac output (ΔmPAP/ΔQ). There were several EIPH and ΔmPAP/ΔQ reference values in individuals with pulmonary vascular disease. We believed that assessing the ΔmPAP/ΔQ makes sense from a physiological standpoint, and the clinical value should be confirmed in future studies. Exercise echocardiography is an appealing alternative in PH. Further studies are needed to assess the prognostic value of the pulmonary artery pressure-flow relationship in high-risk subjects.
Tokuda, Mitsunori; Tabira, Kazuyuki; Masuda, Takashi; Nishiwada, Takashi; Shomoto, Koji
2014-07-01
This study aimed to evaluate the effectiveness of transcutaneous electrical nerve stimulation (TENS) for treatment of postoperative pain and pulmonary functions (vital capacity [VC]; cough peak flow, [CPF]) in patients who underwent abdominal surgery. Forty-eight patients were randomly allocated to receive TENS, placebo TENS, or no TENS (control) 1 hour a day for 3 days postoperatively. A 0-100 visual analog scale was used to assess pain at preintervention, mid-intervention, and postintervention on the third postoperative day. Pulmonary functions (VC, CPF) were evaluated by spirometer at preoperation (baseline) and at preintervention, mid-intervention, and postintervention on the third postoperative day. One-way analysis of variance was used to assess differences between groups at baseline. Mann-Whitney test was used to compare the control group with the placebo-TENS and TENS group, at each assessment timepoint. Two-way analysis of variance and Bonferroni post hoc test assessed the difference between the 2 (placebo-TENS×TENS) groups. A value of P<0.01 was considered statistically significant. The baselines were not significantly different between any groups. The TENS group had significant reductions in postoperative pain compared with the placebo group (P<0.01) and control group (P<0.01). There was also improvement in pulmonary functions (VC, CPF) at mid-TENS and post-TENS, but not in the placebo-TENS (P<0.01) or control groups (P<0.01). TENS is a valuable treatment to alleviate postoperative pain and improve pulmonary functions (ie, VC, CPF) in patients following abdominal surgery.
Laporta, Rosalía; Ussetti, Piedad; Mora, Gema; López, Cristina; Gómez, David; de Pablo, Alicia; Lázaro, M Teresa; Carreño, M Cruz; Ferreiro, M José
2008-08-01
The time at which lung transplantation is indicated is determined by clinical and functional criteria that vary according to the particular disease. The aim of our study was to present the criteria according to which patients were placed on waiting lists for lung transplantation in our hospital. We analyzed retrospectively the clinical characteristics, lung function, heart function, and 6-minute walk test results of patients who had received a lung transplant in our hospital from January 2002 through September 2005. During the study period 100 lung transplants were performed. The mean age of the patients was 45 years (range, 15-67 years) and 57% were men. The diseases that most often led to a lung transplant were chronic obstructive pulmonary disease (COPD) (35%), pulmonary fibrosis (29%), and bronchiectasis (21%). Lung function values differed by disease: mean (SD) forced expiratory volume in 1 second (FEV1) was 20% (11%) and forced vital capacity (FVC) was 37% (15%) in patients with COPD; FEV1 was 41% (15%) and FVC, 40% (17%) in patients with pulmonary fibrosis; and FEV1 was 23% (7%) and FVC, 37% (10%) in patients with bronchiectasis. The patients who received lung transplants in our hospital were in advanced phases of their disease and met the inclusion criteria accepted by the various medical associations when they were placed on the waiting list.
Pulmonary function in patients with Huntington’s Disease
2014-01-01
Background Huntington’s disease (HD) is a neurodegenerative disorder characterized by progressive motor, cognitive and psychiatric disturbances. Chest muscle rigidity, respiratory muscle weakness, difficulty in clearing airway secretions and swallowing abnormalities have been described in patients with neurodegenerative disorders including HD. However limited information is available regarding respiratory function in HD patients. The purpose of this study was to investigate pulmonary function of patients with HD in comparison to healthy volunteers, and its association with motor severity. Methods Pulmonary function measures were taken from 18 (11 male, 7 female) manifest HD patients (53 ± 10 years), and 18 (10 male, 8 female) healthy volunteers (52 ± 11 years) with similar anthropometric and life-style characteristics to the recruited HD patients. Motor severity was quantified by the Unified Huntington’s Disease Rating Scale-Total Motor Score (UHDRS-TMS). Maximum respiratory pressure was measured on 3 separate days with a week interval to assess test-retest reliability. Results The test-retest reliability of maximum inspiratory and expiratory pressure measurements was acceptable for both HD patient and control groups (ICC ≥0.92), but the values over 3 days were more variable in the HD group (CV < 11.1%) than in the control group (CV < 7.6%). The HD group showed lower respiratory pressure, forced vital capacity, peak expiratory flow and maximum voluntary ventilation than the control group (p < 0.05). Forced vital capacity, maximum voluntary ventilation and maximum respiratory pressures were negatively (r = -0.57; -0.71) correlated with the UHDRS-TMS (p < 0.05). Conclusion Pulmonary function is decreased in manifest HD patients, and the magnitude of the decrease is associated with motor severity. PMID:24886346
Blumenthal, James A.; Smith, Patrick J.; Durheim, Michael; Mabe, Stephanie; Emery, Charles F.; Martinu, Tereza; Diaz, Philip T.; Babyak, Michael; Welty-Wolf, Karen; Palmer, Scott
2015-01-01
Objective To examine the prognostic value of select biobehavioral factors in patients with chronic obstructive pulmonary disease (COPD) in a secondary analysis of participants from the INSPIRE-II trial. Methods Three hundred twenty six outpatients with COPD underwent assessments of pulmonary function, physical activity, body mass index, inflammation, pulmonary symptoms, depression, and pulmonary quality of life, and were followed for up to 5.4 years for subsequent clinical events. The prognostic value of each biobehavioral factor, considered individually and combined, also was examined in the context of existing Global Initiative for Chronic Obstructive Lung Disease (GOLD) 2011 risk stratification. Results Sixty-nine individuals experienced a hospitalization or died over a mean follow-up time period of 2.4 (interquartile range = 1.6) years. GOLD classification was associated with an increased risk of clinical events (HR = 2.72 [95% CI 1.63, 4.54], per stage); Six Minute Walk (HR = 0.50 [0.34, 0.73] per 500 feet), total steps (HR = 0.82 [0.71, 0.94] per 1,000 steps), hsC-reactive protein (HR = 1.44 [1.01, 2.06] per 4.5 mg/L), depression (HR = 1.12 [1.01, 1.25] per 4 points), and pulmonary quality of life (HR = 1.73 [1.14, 2.63] per 25 points) were each predictive over and above the GOLD assessment. However, only GOLD group and Six Minute Walk were predictive of all-cause mortality and COPD hospitalization when all biobehavioral variables were included together in a multivariable model. Conclusion Biobehavioral factors provide added prognostic information over and above measures of COPD severity in predicting adverse events in patients with COPD. PMID:26780299
Becker, Tara; Laxova, Anita; Grieve, Adam; Racine Gilles, Caroline N.; Rock, Michael J.; Gershan, William M.; Green, Christopher G.; Farrell, Philip M.
2011-01-01
Background: The objective of this study was to examine relationships between pulmonary health and health-related quality of life (HRQOL) in patients with cystic fibrosis (CF) evaluated longitudinally in the Wisconsin Newborn Screening Project. Methods: Patients aged 8 to 18 years (mean ± SD, 13.5 ± 2.8) in early diagnosis (n = 45) and control (n = 50) groups completed Cystic Fibrosis Questionnaires (CFQs) to measure HRQOL at three data points over a 2-year period. Pulmonary health was evaluated concurrently by the Wisconsin chest x-ray scoring system (WCXR) and pulmonary function tests (PFTs). Results: WCXR showed significant group differences (P ≤ .023), with the early diagnosis group showing more-severe lung disease. When adjusted for group differences in mucoid Pseudomonas aeruginosa status and pancreatic status, however, WCXR differences and PFT data were not significant. Most patients (74%) had FEV1 values ≥ 80% predicted (within normal range). For patients aged < 14 years, as WCXR scores worsened CFQ respiratory and physical domain scores decreased (both P ≤ .007). FEV1/FVC showed a positive relationship with the respiratory and physical domains (both P ≤ .006). WCXR scores for patients aged ≥ 14 years were associated with CFQ weight, respiratory, and health domains (all P ≤ .011). FEV1 was associated with CFQ weight, respiratory, health, and physical domains (all P ≤ .003). Changes in pulmonary health were not associated with changes in CFQ over time. Significant group differences on the CFQ-Child social functioning domain favored the control group. Conclusions: To our knowledge, this study is the first to compare pulmonary outcomes with HRQOL indicators assessed by serial, standardized, patient-reported outcome measures for patients with CF identified either through newborn screening or diagnosed by use of traditional methods. This study found no benefits of newborn screening for pulmonary health or HRQOL after controlling for risk factors. Using WCXR and PFT data collectively helped to identify associations between pulmonary health and HRQOL. PMID:21106659
Pulmonary function after segmentectomy for small peripheral carcinoma of the lung.
Takizawa, T; Haga, M; Yagi, N; Terashima, M; Uehara, H; Yokoyama, A; Kurita, Y
1999-09-01
The aim of this study is to compare the pulmonary function after a segmentectomy with that after a lobectomy for small peripheral carcinoma of the lung. Between 1993 and 1996, segmentectomy and lobectomy were performed on 48 and 133 good-risk patients, respectively. Lymph node metastases were detected after the operation in 6 and 24 patients of the segmentectomy and lobectomy groups, respectively. For bias reduction in comparison with a nonrandomized control group, we paired 40 segmentectomy patients with 40 lobectomy patients using nearest available matching method on the estimated propensity score. Twelve months after the operation, the segmentectomy and lobectomy groups had forced vital capacities of 2.67 +/- 0.73 L (mean +/- standard deviation) and 2.57 +/- 0.59 L, which were calculated to be 94.9% +/- 10.6% and 91.0% +/- 13.2% of the preoperative values (P =.14), respectively. The segmentectomy and lobectomy groups had postoperative 1-second forced expiratory volumes of 1.99 +/- 0.63 L and 1.95 +/- 0.49 L, which were calculated to be 93.3% +/- 10.3% and 87.3% +/- 14.0% of the preoperative values, respectively (P =.03). The multiple linear regression analysis showed that the alternative of segmentectomy or lobectomy was not a determinant for postoperative forced vital capacity but did affect postoperative 1-second forced expiratory volume. Pulmonary function after a segmentectomy for a good-risk patient is slightly better than that after a lobectomy. However, segmentectomy should be still the surgical procedure for only poor-risk patients because of the difficulty in excluding patients with metastatic lymph nodes from the candidates for the procedure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koenig, J.Q.; Covert, D.S.; Smith, M.S.
Separate exposures to 0.12 ppm ozone (O3) or 0.18 ppm nitrogen dioxide (NO2) have not demonstrated consistent changes in pulmonary function in adolescent subjects. However, in polluted urban air, O3 and NO2 occur in combination. Therefore, this project was designed to investigate the pulmonary effects of combined O3 and NO2 exposures during intermittent exercise in adolescent subjects. Twelve healthy and twelve well-characterized asthmatic adolescent subjects were exposed randomly to clean air or 0.12 ppm O3 and 0.30 ppm NO2 alone or in combination during 60 minutes of intermittent moderate exercise (32.5 1/min). The inhalation exposures were carried out while themore » subjects breathed on a rubber mouthpiece with nose clips in place. The following pulmonary functional values were measured before and after exposure: peak flow, total respiratory resistance, maximal flow at 50 and 75 percent of expired vital capacity, forced expiratory volume in one second and forced vital capacity (FVC). Statistical significance of pulmonary function changes was tested by analysis of covariance for repeated measures. After exposure to 0.12 ppm O3 a significant decrease was seen in maximal flow at 50% of FVC in asthmatic subjects. After exposure to 0.30 ppm NO2 a significant decrease was seen in FVC also in the asthmatic subjects. One possible explanation for these changes is the multiple comparison effect. No significant changes in any parameters were seen in the asthmatic subjects after the combined O3-NO2 exposure or in the healthy subjects after any of the exposures.« less
Structural basis for pulmonary functional imaging.
Itoh, H; Nakatsu, M; Yoxtheimer, L M; Uematsu, H; Ohno, Y; Hatabu, H
2001-03-01
An understanding of fine normal lung morphology is important for effective pulmonary functional imaging. The lung specimens must be inflated. These include (a) unfixed, inflated lung specimen, (b) formaldehyde fixed lung specimen, (c) fixed, inflated dry lung specimen, and (d) histology specimen. Photography, magnified view, radiograph, computed tomography, and histology of these specimens are demonstrated. From a standpoint of diagnostic imaging, the main normal lung structures consist of airways (bronchi and bronchioles), alveoli, pulmonary vessels, secondary pulmonary lobules, and subpleural pulmonary lymphatic channels. This review summarizes fine radiologic normal lung morphology as an aid to effective pulmonary functional imaging.
Fogel, Mark A; Sundareswaran, Kartik S; de Zelicourt, Diane; Dasi, Lakshmi P; Pawlowski, Tom; Rome, Jack; Yoganathan, Ajit P
2012-06-01
To quantify right ventricular output power and efficiency and correlate these to ventricular function in patients with repaired tetralogy of Fallot. This might aid in determining the optimal timing for pulmonary valve replacement. We reviewed the cardiac catheterization and magnetic resonance imaging data of 13 patients with tetralogy of Fallot (age, 22 ± 17 years). Using pressure and flow measurements in the main pulmonary artery, cardiac output and regurgitation fraction, right ventricular (RV) power output, loss, and efficiency were calculated. The RV function was evaluated using cardiac magnetic resonance imaging. The RV systolic power was 1.08 ± 0.62 W, with 20.3% ± 8.6% power loss owing to 41% ± 14% pulmonary regurgitation (efficiency, 79.7% ± 8.6%; 0.84 ± 0.73 W), resulting in a net cardiac output of 4.24 ± 1.82 L/min. Power loss correlated significantly with the indexed RV end-diastolic and end-systolic volume (R = 0.78, P = .002 and R = 0.69, P = .009, respectively). The normalized RV power output had a significant negative correlation with RV end-diastolic and end-systolic volumes (both R = -0.87, P = .002 and R = -0.68, P = .023, respectively). A rapid decrease occurred in the RV power capacity with an increasing RV volume, with the curve flattening out at an indexed RV end-diastolic and end-systolic volume threshold of 139 mL/m(2) and 75 mL/m(2), respectively. Significant power loss is present in patients with repaired tetralogy of Fallot and pulmonary regurgitation. A rapid decrease in efficiency occurs with increasing RV volume, suggesting that pulmonary valve replacement should be done before the critical value of 139 mL/m(2) and 75 mL/m(2) for the RV end-diastolic and end-systolic volume, respectively, to preserve RV function. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Fitness and lung function in children with primary ciliary dyskinesia and cystic fibrosis.
Ring, Astrid M; Buchvald, Frederik F; Holgersen, Mathias G; Green, Kent; Nielsen, Kim G
2018-06-01
Peak oxygen uptake (VO 2peak ) is associated with morbidity and mortality in health and disease, and provides important information of global physical health not achieved from standard pulmonary function tests. Primary ciliary dyskinesia (PCD) and cystic fibrosis (CF) are genetically determined diseases involving different basic defects, but both showing impaired mucociliary clearance leading to chronic infections and pulmonary destruction early in life. PCD is generally considered a milder disease than CF and it is hypothesized that children with CF would have consistently lower VO 2peak and pulmonary function than children with PCD. We performed a prospective, observational single-center, clinical cohort study of VO 2peak and pulmonary function in age and gender matched schoolchildren, at two occasions 12 months apart. VO 2peak was persistently (at baseline and after 12 months) and significantly reduced in the 22 patients with PCD (z-score = -0.89 and -1.0) and 24 with CF (z-score = -0.94 and -1.1), included in the study. Abnormal VO 2peak was detected in a larger proportion of children with PCD (≈30%) than CF (≈13%). Moreover, children with PCD exhibited persistently lower FEV 1 (p < 0.0001 at first visit and p = 0.001 at second visit) while FEF 25-75 and FVC differed only at baseline. Indeed, a retrospective analysis comparing lung function over the last year in our entire PCD and CF populations between 6 and 18 years of age, revealed lower values in patients with PCD (FEV 1 z-score, p = 0.0004, FVC z-score p < 0.0001, FEF 25-75 z-score p = 0.008). This is the first report indicating that cardiopulmonary fitness is equally and consistently reduced in both children with PCD and CF along with a consistent lower pulmonary function in PCD compared with CF. A certain reservation for possible selection bias and the small number of patients is necessary. However, increased focus on early diagnosis, evidence-based treatment regimens and close clinical monitoring in PCD are warranted. Copyright © 2018 Elsevier Ltd. All rights reserved.
Incidence and risk factors of Pulmonary Complications after Cardiopulmonary bypass
Naveed, Anjum; Azam, Hammad; Murtaza, Humayoun Ghulam; Ahmad, Rana Altaf; Baig, Mirza Ahmad Raza
2017-01-01
Objective: To determine the frequency of post-operative pulmonary complications (PPCs) after cardio-pulmonary bypass and association of pre-operative and intraoperative risk factors with incidence of PPCs. Methods: This study was an observational analysis of five hundred and seventeen (517) patients who underwent cardiac surgery using cardiopulmonary bypass. Incidence of PPCs and risk factors of PPCs were noted. Logistic regression was applied to determine the association of pre-operative and intraoperative risk factors with incidence of PPCs. Results: Post-operative pulmonary complications occurred in 32 (6.2%) patients. Most common post-operative pulmonary complication was atelectasis that occurred in 20 (3.86%) patients, respiratory failure in 8 (1.54%) patients, pneumonia in 3 (0.58%) patients and acute respiratory distress syndrome in 1 (0.19%) patients. The main risk factor of PPCs were advance age ≥ 60 years [odds ratio 4.16 (1.99-8.67), p-value <0.001], prolonged CPB time > 120 minutes [odds ratio 3.62 (1.46-8.97) p-value 0.003], pre-op pulmonary hypertension [odds ratio 2.60 (1.18-5.73), p-value 0.016] and intraoperative phrenic nerve injury [odds ratio 7.06 (1.73-28.74), p-value 0.002]. Operative mortality was 9.4% in patients with PPCs and 1.0% in patients without PPCs (p-value 0.01). Conclusion: The incidence of post-operative pulmonary complications was 6.2% in this study. Advanced age (age ≥ 60 years), prolonged CPB time (CPB time > 120 minutes), pre-op pulmonary hypertension and intraoperative phrenic nerve injury are independent risk factors of PPCs after surgery. PMID:29067080
Incidence and risk factors of Pulmonary Complications after Cardiopulmonary bypass.
Naveed, Anjum; Azam, Hammad; Murtaza, Humayoun Ghulam; Ahmad, Rana Altaf; Baig, Mirza Ahmad Raza
2017-01-01
To determine the frequency of post-operative pulmonary complications (PPCs) after cardio-pulmonary bypass and association of pre-operative and intraoperative risk factors with incidence of PPCs. This study was an observational analysis of five hundred and seventeen (517) patients who underwent cardiac surgery using cardiopulmonary bypass. Incidence of PPCs and risk factors of PPCs were noted. Logistic regression was applied to determine the association of pre-operative and intraoperative risk factors with incidence of PPCs. Post-operative pulmonary complications occurred in 32 (6.2%) patients. Most common post-operative pulmonary complication was atelectasis that occurred in 20 (3.86%) patients, respiratory failure in 8 (1.54%) patients, pneumonia in 3 (0.58%) patients and acute respiratory distress syndrome in 1 (0.19%) patients. The main risk factor of PPCs were advance age ≥ 60 years [odds ratio 4.16 (1.99-8.67), p-value <0.001], prolonged CPB time > 120 minutes [odds ratio 3.62 (1.46-8.97) p-value 0.003], pre-op pulmonary hypertension [odds ratio 2.60 (1.18-5.73), p-value 0.016] and intraoperative phrenic nerve injury [odds ratio 7.06 (1.73-28.74), p-value 0.002]. Operative mortality was 9.4% in patients with PPCs and 1.0% in patients without PPCs (p-value 0.01). The incidence of post-operative pulmonary complications was 6.2% in this study. Advanced age (age ≥ 60 years), prolonged CPB time (CPB time > 120 minutes), pre-op pulmonary hypertension and intraoperative phrenic nerve injury are independent risk factors of PPCs after surgery.
Bao, Hongda; Yan, Peng; Bao, Mike; Qiu, Yong; Zhu, Zezhang; Liu, Zhen; Cheng, Jack C Y; Ng, Bobby K W; Zhu, Feng
2016-08-01
To investigate the change of pulmonary function in adult scoliosis patients with respiratory dysfunction undergoing HGT combined with assisted ventilation. 21 adult patients were retrospectively reviewed with a mean age of 26.2 years. Inclusion criteria were as follows: age over 18 years old; coronal Cobb angle greater than 100°; with respiratory failure; and duration of HGT more than 1 month. All patients underwent respiratory training. The Cobb angle averaged 131.21° and was reduced to 107.68° after HGT. Significantly increased mean forced vital capacity (FVC) was found after HGT (P = 0.003) with significantly improved percent-predicted values for FVC (P < 0.001). Meanwhile, significantly increased forced expiratory volume in 1 s (FEV1) was also observed (P < 0.001) with significantly improved percent-predicted values for FEV1 (P = 0.003) after HGT. The results of our study revealed that combined HGT and assisted ventilation would be beneficial to pulmonary function improvement in severe adult scoliosis cases, most of which were young adults.
[Lung dysfunction in patients with mild chronic obstructive bronchitis].
Nefedov, V B; Popova, L A; Shergina, E A
2004-01-01
VC, FVC, FEV1, FEV1/VC%, PEF, MEF25, MEF50, MEF75, TCL, TGV, RV, Ravt, Riin, Rex, DLCO-SS, PaO2, and PaO2 were determined in 33 patients with mild chronic obstructive lung disease (FEV1 > 70% of the normal value). All the patients were found to have impaired bronchial patency; most (63.6%) patients had lung volume and capacity changes, almost half (45.5%) the patients had pulmonary gas exchange dysfunction. Impaired bronchial patency mainly appeared as decreased MEF50, MEF15, and FEV1/VC%; altered lung volumes and capacities manifested chiefly by increased RV and decreased VC; pulmonary gas exchange dysfunction showed up primarily as lowered PaO2. The magnitude of the observed functional changes was generally slight. MEF50, MEF75, FEV1/VC%, and VC dropped to 59-20 and 79-70% of the normal value, respectively. RV increased up to 142-196% of the normal value; PaO2 reduced up to 79-60% mm Hg.
Adams, William C
2003-07-01
While direct comparison of pulmonary responses to 6.6-h exposures to 0.08 to 0.12 ppm ozone O3 have demonstrated that chamber and face-mask inhalation methods yield closely similar results, no comparative study of responses to 2-h intermittent exercise (IE) exposures to higher O3 concentrations have been reported. The present study was designed to achieve three primary objectives: (1) to compare pulmonary function and symptoms effects of a 2-h IE exposure to 0.30 ppm O3 via chamber and via face mask; (2) to compare the pulmonary effects of 6.6-h chamber exposure to 0.08 ppm O3 to those observed in 2-h IE 0.30 ppm O3 exposures via chamber and via face mask; and (3) to examine filtered air (FA) recovery pulmonary and symptoms responses following chamber exposures of 6.6 h to 0.08 ppm O3 and 2 h to 0.30 ppm O3. A simple regression of postexposure percent change in FEV(1.0) for the 2-h IE, 0.30-ppm O3 chamber exposure as a function of postexposure percent change in FEV(1.0) for the 2-h IE, 0.30-ppm O3 exposure with face mask yielded an R(2) of 0.83. Further, a regression of the postexposure FEV(1.0) response to the chamber 6.6-h, 0.08-ppm O3 exposure as a function of postexposure FEV(1.0) response to the face mask 2-h IE, 0.30-ppm O3 exposure (R(2) of 0.34) was similar to the 0.40 value obtained for the two chamber exposures FEV(1.0) response comparison. Results of the 1.4-h FA recovery following the two chamber O3 exposures showed different rates of FEV(1.0) and symptoms rectification that appeared related to the total O3 dose (product of O3 concentration, ventilation rate, and duration). More data are needed to clarify short-term recovery of O3-induced pulmonary effects and how they may be related to the more abundant data available on the delayed recovery of pulmonary function seen over longer time periods, such as 24 h.
Cayir, Derya; Demirel, Koray; Korkmaz, Meliha; Koca, Gokhan
2011-10-01
Chronic inhalant use is associated with significant toxic effects, including neurological, renal, hepatic, and pulmonary damage. However, there is a paucity of reports regarding respiratory complications in inhalant abusers. The aim of this study was to evaluate pulmonary epithelial permeability in the volatile substance abuse (VSA) using Tc-99m DTPA aerosol scintigraphy. This study included 18 patients with volatile substance abuse and 18 volunteer controls. All of patients and controls were smokers. Tc-99m DTPA aerosol scintigraphy was performed in all cases. Time-activity curves from each lung were generated and clearance half-time (T(1/2)) of Tc-99m DTPA were calculated. T(1/2) of whole lung was calculated as a mean of the T(1/2) of left and right lung. The T(1/2) values of Tc-99m DTPA clearance in the substance abusers were significantly decreased as compared to the control group with respective mean values of 28.86 ± 8.44, and 62.14 ± 26.12 min (p = 0.001). It was seen Tc-99m DTPA clearance from lung was faster as the duration of substance abuse was increased. Tc-99m DTPA pulmonary clearance is markedly accelerated in the volatile substance abuse. This suggests that inhalant abuse of substance may produce abnormalities in pulmonary alveolo-capillary membrane function.
Kumar, Gaurav; Rawat, Sheh; Puri, Abhishek; Sharma, Manoj Kumar; Chadha, Pranav; Babu, Anand Giri; Yadav, Girigesh
2012-01-01
Multimodality therapy for esophageal cancer can cause various kinds of treatment-related sequelae, especially pulmonary toxicities. This prospective study aims to investigate the clinical and dosimetric parameters predicting lung injury in patients undergoing radiation therapy for esophageal cancer. Forty-five esophageal cancer patients were prospectively analyzed. The pulmonary toxicities (or sequelae) were evaluated by comparing chest X-ray films, pulmonary function tests and symptoms caused by pulmonary damage before and after treatment. All patients were treated with either three-dimensional radiotherapy (3DCRT) or with intensity-modulated radiotherapy (IMRT). The planning dose volume histogram was used to compute the lung volumes receiving more than 5, 10, 20 and 30 Gy (V5, V10, V20, V30) and mean lung dose. V20 was larger in the IMRT group than in the 3DCRT group (p = 0.002). V20 (>15%) and V30 (>20%) resulted in a statistically significant increase in the occurrence of chronic pneumonitis (p = 0.03) and acute pneumonitis (p = 0.007), respectively. The study signifies that a larger volume of lung receives lower doses because of multiple beam arrangement and a smaller volume of lung receives higher doses because of better dose conformity in IMRT plans. Acute pneumonitis correlates more with V30 values, whereas chronic pneumonitis was predominantly seen in patients with higher V20 values.
Gavini, S; Borges, L F; Finn, R T; Lo, W-K; Goldberg, H J; Burakoff, R; Feldman, N; Chan, W W
2017-05-01
Gastroesophageal reflux (GER) has been associated with idiopathic pulmonary fibrosis (IPF). Pathogenesis may be related to chronic micro-aspiration. We aimed to assess objective measures of GER on multichannel intraluminal impedance and pH study (MII-pH) and their relationship with pulmonary function testing (PFT) results, and to compare the performance of pH/acid reflux parameters vs corresponding MII/bolus parameters in predicting pulmonary dysfunction in IPF. This was a retrospective cohort study of IPF patients undergoing prelung transplant evaluation with MII-pH off acid suppression, and having received PFT within 3 months. Patients with prior fundoplication were excluded. Severe pulmonary dysfunction was defined using diffusion capacity of the lung for carbon monoxide (DLCO) ≤40%. Six pH/acid reflux parameters with corresponding MII/bolus reflux measures were specified a priori. Multivariate analyses were applied using forward stepwise logistic regression. Predictive value of each parameter for severe pulmonary dysfunction was calculated by area-under-the-receiver-operating-characteristic-curve or c-statistic. Forty-five subjects (67% M, age 59, 15 mild-moderate vs 30 severe) met criteria for inclusion. Patient demographics and clinical characteristics were similar between pulmonary dysfunction groups. Abnormal total reflux episodes and prolonged bolus clearance time were significantly associated with pulmonary dysfunction severity on univariate and multivariate analyses. No pH parameters were significant. The c-statistic of each pH parameter was lower than its MII counterpart in predicting pulmonary dysfunction. MII/bolus reflux, but not pH/acid reflux, was associated with pulmonary dysfunction in prelung transplant patients with IPF. MII-pH may be more valuable than pH testing alone in characterizing GER in IPF. © 2016 John Wiley & Sons Ltd.
Farias, Catharinne C.; Resqueti, Vanessa; Dias, Fernando A. L.; Borghi-Silva, Audrey; Arena, Ross; Fregonezi, Guilherme A. F.
2014-01-01
Objective The current study evaluated the costs and benefits of a simple aerobic walking program for patients with chronic obstructive pulmonary disease (COPD). Method This was a blinded randomized controlled clinical trial that recruited 72 patients diagnosed with COPD, 40 of whom were included in the study and divided into two groups [control group (CG) and pulmonary rehabilitation group (GPR)]. We assessed pulmonary function, distance covered during the 6-minute walk test (6MWT), respiratory and peripheral muscle strength, health-related quality of life (HRQOL), body composition, and level of activities of daily living (ADLs) before and after an 8-week walking program. The financial costs were calculated according to the pricing table of the Brazilian Unified Health System (SUS). Results Only 34 of the 40 patients remained in the final sample; 16 in the CG and 18 in the GPR (FEV1: 50.9±14% predicted and FEV1: 56±0.5% predicted, respectively). The intervention group exhibited improvements in the 6MWT, sensation of dyspnea and fatigue, work performed, BODE index (p<0.01), HRQOL, ADL level (p<0.001), and lower limb strength (p<0.05). The final mean cost per patient for the GPR was R$ 148.75 (~US$ 75.00) and no patient significantly exceeded this value. However, 2 patients in the CG did exceed this value, incurring a cost of R$ 689.15 (~US$ 345.00). Conclusion Aerobic walking demonstrated significant clinical benefits in a cost-efficient manner in patients with COPD. PMID:24838809
Yang, Xiaotian; Zhou, Yujing; Wang, Pu; He, Chengqi; He, Hongchen
2016-05-01
To examine the effect of whole-body vibration in enhancing pulmonary function, functional exercise capacity and quality of life in people with chronic obstructive pulmonary disease and examine its safety. Randomized controlled trials examining the effects of whole body vibration among people with chronic obstructive pulmonary disease were identified by two independent researchers. Articles were excluded if they were studies on people with other primary diagnosis, abstracts published in the conferences or books. PEDro scale was used to assess the methodological quality of the selected studies. We evaluated the level of evidence by using the GRADE approach. The results were extracted by two researchers and confirmed by the third researcher if disagreement existed. Sources included Cochrane Central Register of Controlled Trials, PubMed, CINAHL, EMBASE, PEDro, AMED, PsycINFO, ClinicalTrials.gov, Current Controlled Trials and reference lists of all relevant articles. Four studies involving 206 participants were included in this systematic review. Methodological quality was rated as good for two studies. No great benefits on pulmonary function were found in whole body vibration treatment group. Two studies showed that quality of life was improved in people with chronic obstructive pulmonary disease. Whole body vibration led to significant improvements in functional exercise capacity measured with six minutes walking test. Nearly no adverse events were observed. Whole body vibration may improve functional exercise capacity and quality of life in people with chronic obstructive pulmonary disease. There was insufficient evidence to prove the effects of whole body vibration on pulmonary function. © The Author(s) 2015.
Lobar analysis of collapsibility indices to assess functional lung volumes in COPD patients.
Kitano, Mariko; Iwano, Shingo; Hashimoto, Naozumi; Matsuo, Keiji; Hasegawa, Yoshinori; Naganawa, Shinji
2014-01-01
We investigated correlations between lung volume collapsibility indices and pulmonary function test (PFT) results and assessed lobar differences in chronic obstructive pulmonary disease (COPD) patients, using paired inspiratory and expiratory three dimensional (3D) computed tomography (CT) images. We retrospectively assessed 28 COPD patients who underwent paired inspiratory and expiratory CT and PFT exams on the same day. A computer-aided diagnostic system calculated total lobar volume and emphysematous lobar volume (ELV). Normal lobar volume (NLV) was determined by subtracting ELV from total lobar volume, both for inspiratory phase (NLVI) and for expiratory phase (NLVE). We also determined lobar collapsibility indices: NLV collapsibility ratio (NLVCR) (%)=(1-NLVE/NLVI)×100%. Associations between lobar volumes and PFT results, and collapsibility indices and PFT results were determined by Pearson correlation analysis. NLVCR values were significantly correlated with PFT results. Forced expiratory volume in 1 second, measured as percent of predicted results (FEV1%P) was significantly correlated with NLVCR values for the lower lobes (P<0.01), whereas this correlation was not significant for the upper lobes (P=0.05). FEV1%P results were also moderately correlated with inspiratory, expiratory ELV (ELVI,E) for the lower lobes (P<0.05). In contrast, the ratio of the diffusion capacity for carbon monoxide to alveolar gas volume, measured as percent of predicted (DLCO/VA%P) results were strongly correlated with ELVI for the upper lobes (P<0.001), whereas this correlation with NLVCR values was weaker for upper lobes (P<0.01) and was not significant for the lower lobes (P=0.26). FEV1%P results were correlated with NLV collapsibility indices for lower lobes, whereas DLCO/VA%P results were correlated with NLV collapsibility indices and ELV for upper lobes. Thus, evaluating lobar NLV collapsibility might be useful for estimating pulmonary function in COPD patients.
Pulmonary function and the risk of functional limitation in chronic obstructive pulmonary disease.
Eisner, Mark D; Iribarren, Carlos; Yelin, Edward H; Sidney, Stephen; Katz, Patricia P; Ackerson, Lynn; Lathon, Phenius; Tolstykh, Irina; Omachi, Theodore; Byl, Nancy; Blanc, Paul D
2008-05-01
The authors' objective was to analyze the impact of respiratory impairment on the risk of physical functional limitations among adults with chronic obstructive pulmonary disease (COPD). They hypothesized that greater pulmonary function decrement would result in a broad array of physical functional limitations involving organ systems remote from the lung, a key step in the pathway leading to overall disability. The authors used baseline data from the Function, Living, Outcomes, and Work (FLOW) study, a prospective cohort study of adults with COPD recruited from northern California in 2005-2007. They studied the impact of pulmonary function impairment on the risk of functional limitations using validated measures: lower extremity function (Short Physical Performance Battery), submaximal exercise performance (6-Minute Walk Test), standing balance (Functional Reach Test), skeletal muscle strength (manual muscle testing with dynamometry), and self-reported functional limitation (standardized item battery). Multiple variable analysis was used to control for confounding by age, sex, race, height, educational attainment, and cigarette smoking. Greater pulmonary function impairment, as evidenced by lower forced expiratory volume in 1 second (FEV(1)), was associated with poorer Short Physical Performance Battery scores and less distance walked during the 6-Minute Walk Test. Lower forced expiratory volume in 1 second was also associated with weaker muscle strength and with a greater risk of self-reported functional limitation (p < 0.05). In conclusion, pulmonary function impairment is associated with multiple manifestations of physical functional limitation among COPD patients. Longitudinal follow-up can delineate the impact of these functional limitations on the prospective risk of disability, guiding preventive strategies that could attenuate the disablement process.
Higher Plasma Myostatin Levels in Cor Pulmonale Secondary to Chronic Obstructive Pulmonary Disease.
Ju, Chun-Rong; Chen, Miao; Zhang, Jian-Heng; Lin, Zhi-Ya; Chen, Rong-Chang
2016-01-01
To analyze plasma myostatin levels and investigate their relationship with right ventricular (RV) function in patients with cor pulmonale secondary to chronic obstructive pulmonary disease (COPD). The study recruited 81 patients with advanced COPD and 40 age-matched controls. The patients were divided into two groups: those with cor pulmonale and those without. Echocardiography was used to evaluate RV function and morphology, and the value of tricuspid annular plane systolic excursion (TAPSE) less than 16 mm was considered RV dysfunction. Plasma myostatin levels were analyzed by enzyme-linked immunosorbent assay, and B-type natriuretic peptide (BNP) levels were analyzed as a comparison of myostatin. The data detected cor pulmonale in 39/81 patients, with the mean value of TAPSE of 14.3 mm. Plasma myostatin levels (ng/mL) were significantly higher in patients with cor pulmonale (16.68 ± 2.95) than in those without (13.56 ± 3.09), and much higher than in controls (8.79±2.79), with each p<0.01. Significant differences were also found in plasma BNP levels among the three groups (p<0.05). Multivariate regression analysis suggested that myostatin levels were significantly correlated with the values of TAPSE and RV myocardium performance index among the COPD patients, and that BNP levels were significantly correlated only with systolic pulmonary arterial pressure, with each p<0.05. Plasma myostatin levels are increased in COPD patients who have cor pulmonale. Stronger correlations of plasma myostatin levels with echocardiographic indexes of the right heart suggest that myostatin might be superior to BNP in the early diagnosis of cor pulmonale in COPD.
Higher Plasma Myostatin Levels in Cor Pulmonale Secondary to Chronic Obstructive Pulmonary Disease
Ju, Chun-rong; Chen, Miao; Zhang, Jian-heng; Lin, Zhi-ya; Chen, Rong-chang
2016-01-01
Objective To analyze plasma myostatin levels and investigate their relationship with right ventricular (RV) function in patients with cor pulmonale secondary to chronic obstructive pulmonary disease (COPD). Methods The study recruited 81 patients with advanced COPD and 40 age-matched controls. The patients were divided into two groups: those with cor pulmonale and those without. Echocardiography was used to evaluate RV function and morphology, and the value of tricuspid annular plane systolic excursion (TAPSE) less than 16 mm was considered RV dysfunction. Plasma myostatin levels were analyzed by enzyme-linked immunosorbent assay, and B-type natriuretic peptide (BNP) levels were analyzed as a comparison of myostatin. Results The data detected cor pulmonale in 39/81 patients, with the mean value of TAPSE of 14.3 mm. Plasma myostatin levels (ng/mL) were significantly higher in patients with cor pulmonale (16.68 ± 2.95) than in those without (13.56 ± 3.09), and much higher than in controls (8.79±2.79), with each p<0.01. Significant differences were also found in plasma BNP levels among the three groups (p<0.05). Multivariate regression analysis suggested that myostatin levels were significantly correlated with the values of TAPSE and RV myocardium performance index among the COPD patients, and that BNP levels were significantly correlated only with systolic pulmonary arterial pressure, with each p<0.05. Conclusions Plasma myostatin levels are increased in COPD patients who have cor pulmonale. Stronger correlations of plasma myostatin levels with echocardiographic indexes of the right heart suggest that myostatin might be superior to BNP in the early diagnosis of cor pulmonale in COPD. PMID:26998756
NASA Astrophysics Data System (ADS)
Lee, Minho; Kim, Namkug; Lee, Sang Min; Seo, Joon Beom; Oh, Sang Young
2015-03-01
To quantify low attenuation area (LAA) of emphysematous regions according to cluster size in 3D volumetric CT data of chronic obstructive pulmonary disease (COPD) patients and to compare these indices with their pulmonary functional test (PFT). Sixty patients with COPD were scanned by a more than 16-multi detector row CT scanner (Siemens Sensation 16 and 64) within 0.75mm collimation. Based on these LAA masks, a length scale analysis to estimate each emphysema LAA's size was performed as follows. At first, Gaussian low pass filter from 30mm to 1mm kernel size with 1mm interval on the mask was performed from large to small size, iteratively. Centroid voxels resistant to the each filter were selected and dilated by the size of the kernel, which was regarded as the specific size emphysema mask. The slopes of area and number of size based LAA (slope of semi-log plot) were analyzed and compared with PFT. PFT parameters including DLco, FEV1, and FEV1/FVC were significantly (all p-value< 0.002) correlated with the slopes (r-values; -0.73, 0.54, 0.69, respectively) and EI (r-values; -0.84, -0.60, -0.68, respectively). In addition, the D independently contributed regression for FEV1 and FEV1/FVC (adjust R sq. of regression study: EI only, 0.70, 0.45; EI and D, 0.71, 0.51, respectively). By the size based LAA segmentation and analysis, we evaluated the Ds of area, number, and distribution of size based LAA, which would be independent factors for predictor of PFT parameters.
Hayashida, Mie; Yasuo, Masanori; Hanaoka, Masayuki; Seyama, Kuniaki; Inoue, Yoshikazu; Tatsumi, Koichiro; Mishima, Michiaki
2016-05-01
In lymphangioleiomyomatosis (LAM), predicting lung disease progression is essential for treatment planning. However, no previous Japanese studies have attempted to predict the reductions in pulmonary function that occur in LAM patients. The data for 89 LAM patients who had undergone ≥3 spirometry tests and whose data had been registered in the Japanese National Research Project on Intractable Diseases database between October 2009 and March 2014 were analyzed after excluding patients who had undergone (1) a lung transplant; (2) mTOR inhibitor treatment; or (3) thoracic drainage, pleurodesis, surgery, or thoracic duct ligation during the study period. The rates of change (slope) in pulmonary parameters were calculated, and their associations with clinical background factors were investigated. Among the whole study population, the median (quartiles) slope of forced expiratory volume in one second (FEV1) was -46.7 (-95.2; -15.0)mL per year. Episodes of conservatively treated pneumothorax during the study period were found to be associated with rapid reductions in FEV1 (% predicted). Pregnancy during the study period was associated with a reduction in FEV1 (% predicted). When the patients were divided into those who exhibited initial FEV1 (% predicted) values of >70% (Group A) and ≤70% (Group B), Group B displayed significantly faster reductions in FEV1 (% predicted) than Group A. LAM patients whose initial FEV1 (% predicted) values are ≤70% subsequently exhibit rapid reductions in their FEV1 values, and hence, require treatment. However, the FEV1 reduction rate varies markedly among individuals and should be monitored in all cases. Copyright © 2015 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.
Aydemir, Koray; Tok, Fatih; Peker, Fatma; Safaz, Ismail; Taskaynatan, Mehmet Ali; Ozgul, Ahmet
2010-01-01
This study aimed to determine the effects of balneotherapy on disease activity, functional status, metrology index, pulmonary function and quality of life in patients with ankylosing spondylitis (AS). The study included 28 patients (27 male and 1 female) diagnosed with AS according to modified New York criteria. The patients were treated with balneotherapy for 3 weeks (30 min/day, 5 days/week). The patients were evaluated using the global index, Bath ankylosing spondylitis disease activity index (BASDAI), disease functional index (BASFI), metrology index (BASMI), chest expansion measures, pulmonary function testing, and the medical outcomes study-short form-36 Health Survey (SF-36) (measure of quality of life) before balneotherapy and 1 month after treatment. Post balneotherapy BASDAI and global index decreased, BASMI parameters improved, chest expansion increased, and some SF-36 parameters improved; however, none of these changes were statistically significant (P > 0.05), except for the decrease in BASMI total score (P < 0.05). Before balneotherapy 6 patients had restrictive pulmonary disorder, according to pulmonary function test results. Pulmonary function test results in 3 (50%) patients were normalized following balneotherapy; however, as for the other index, balneotherapy did not significantly affect pulmonary function test results. The AS patients' symptoms, clinical findings, pulmonary function test results, and quality of life showed a trend to improve following balneotherapy, although without reaching significant differences. Comprehensive randomized controlled spa intervention studies with longer follow-up periods may be helpful in further delineating the therapeutic efficacy of balneotherapy in AS patients.
Richter, Manuel J.; Grimminger, Jan; Krüger, Britta; Ghofrani, Hossein A.; Mooren, Frank C.; Gall, Henning; Pilat, Christian; Krüger, Karsten
2017-01-01
Pulmonary hypertension (PH) is characterized by severe exercise limitation mainly attributed to the impairment of right ventricular function resulting from a concomitant elevation of pulmonary vascular resistance and pressure. The unquestioned cornerstone in the management of patients with pulmonary arterial hypertension (PAH) is specific vasoactive medical therapy to improve pulmonary hemodynamics and strengthen right ventricular function. Nevertheless, evidence for a beneficial effect of exercise training (ET) on pulmonary hemodynamics and functional capacity in patients with PH has been growing during the past decade. Beneficial effects of ET on regulating factors, inflammation, and metabolism have also been described. Small case-control studies and randomized clinical trials in larger populations of patients with PH demonstrated substantial improvements in functional capacity after ET. These findings were accompanied by several studies that suggested an effect of ET on inflammation, although a direct link between this effect and the therapeutic benefit of ET in PH has not yet been demonstrated. On this background, the aim of the present review is to describe current concepts regarding the effects of exercise on the pulmonary circulation and pathophysiological limitations, as well as the clinical and mechanistic effects of exercise in patients with PH. PMID:28680563
Cardiopulmonary and Metabolic Effects of Yoga in Healthy Volunteers
Divya, T Satheesh; Vijayalakshmi, MT; Mini, K; Asish, K; Pushpalatha, M; Suresh, Varun
2017-01-01
Background: Yoga the spiritual union of mind with the divine intelligence of the universe aims to liberate a human being from conflicts of body–mind duality. Beneficial cardiovascular and pulmonary effects of yoga are in par with aerobic exercise, even amounting to replace the exercise model. We conducted an interventional study in healthy volunteers, to analyze the impact of short-term yoga training on cardiovascular, pulmonary, autonomic function tests, lipid profile, and thyroid function tests. Materials and Methods: A sample of fifty new recruits attending the district yoga center was subject to 75 min yoga practice a day for 41 days. Basal values of cardiovascular, pulmonary, autonomic function tests, lipid profile, and thyroid function tests were recorded before yoga training and were reassessed for postyoga changes after 41 days. Results: After yoga practice there was a significant reduction in the resting heart rate, systolic blood pressure, diastolic blood pressure, and mean blood pressure of the participants. Effects on autonomic function tests were variable and inconclusive. There was a significant increase in forced vital capacity, forced expiratory volume in 1 s, and peak expiratory flow rate after yoga. A significant reduction in body mass index was observed. Effects on metabolic parameters were promising with a significant reduction in fasting blood sugar level, serum total cholesterol, serum triglycerides serum low-density lipoprotein levels, and significant increase in high-density lipoprotein. There was no significant change in thyroid function tests after yoga. Conclusion: Short-term yoga practice has no effect on thyroid functions. Yoga practice was found beneficial in maintaining physiological milieu pertaining to cardiovascular and other metabolic parameters. PMID:29422741
Cardiopulmonary and Metabolic Effects of Yoga in Healthy Volunteers.
Divya, T Satheesh; Vijayalakshmi, M T; Mini, K; Asish, K; Pushpalatha, M; Suresh, Varun
2017-01-01
Yoga the spiritual union of mind with the divine intelligence of the universe aims to liberate a human being from conflicts of body-mind duality. Beneficial cardiovascular and pulmonary effects of yoga are in par with aerobic exercise, even amounting to replace the exercise model. We conducted an interventional study in healthy volunteers, to analyze the impact of short-term yoga training on cardiovascular, pulmonary, autonomic function tests, lipid profile, and thyroid function tests. A sample of fifty new recruits attending the district yoga center was subject to 75 min yoga practice a day for 41 days. Basal values of cardiovascular, pulmonary, autonomic function tests, lipid profile, and thyroid function tests were recorded before yoga training and were reassessed for postyoga changes after 41 days. After yoga practice there was a significant reduction in the resting heart rate, systolic blood pressure, diastolic blood pressure, and mean blood pressure of the participants. Effects on autonomic function tests were variable and inconclusive. There was a significant increase in forced vital capacity, forced expiratory volume in 1 s, and peak expiratory flow rate after yoga. A significant reduction in body mass index was observed. Effects on metabolic parameters were promising with a significant reduction in fasting blood sugar level, serum total cholesterol, serum triglycerides serum low-density lipoprotein levels, and significant increase in high-density lipoprotein. There was no significant change in thyroid function tests after yoga. Short-term yoga practice has no effect on thyroid functions. Yoga practice was found beneficial in maintaining physiological milieu pertaining to cardiovascular and other metabolic parameters.
Armbrust, Laura J; Biller, David S; Bamford, Aubrey; Chun, Ruthanne; Garrett, Laura D; Sanderson, Michael W
2012-05-01
To compare the detection of pulmonary nodules by use of 3-view thoracic radiography and CT in dogs with confirmed neoplasia. Prospective case series. 33 dogs of various breeds. 3 interpreters independently evaluated 3-view thoracic radiography images. The location and size of pulmonary nodules were recorded. Computed tomographic scans of the thorax were obtained and evaluated by a single interpreter. The location, size, margin, internal architecture, and density of pulmonary nodules were recorded. Sensitivity, specificity, positive predictive value, and negative predictive value were calculated for thoracic radiography (with CT as the gold standard). 21 of 33 (64%) dogs had pulmonary nodules or masses detected on CT. Of the dogs that had positive CT findings, 17 of 21 (81%) had pulmonary nodules or masses detected on radiographs by at least 1 interpreter. Sensitivity of radiography ranged from 71% to 95%, and specificity ranged from 67% to 92%. Radiography had a positive predictive value of 83% to 94% and a negative predictive value of 65% to 89%. The 4 dogs that were negative for nodules on thoracic radiography but positive on CT were all large-breed to giant-breed dogs with osteosarcoma. CT was more sensitive than radiography for detection of pulmonary nodules. This was particularly evident in large-breed to giant-breed dogs. Thoracic CT is recommended in large-breed to giant-breed dogs with osteosarcoma if the detection of pulmonary nodules will change treatment.
Pulmonary function parameters and use of bronchodilators in patients with cystic fibrosis*
Muramatu, Lucia Harumi; Stirbulov, Roberto; Forte, Wilma Carvalho Neves
2013-01-01
OBJECTIVE: To analyze pulmonary function parameters and pharmacodynamic response to a bronchodilator, as well as the prescription of bronchodilators, in cystic fibrosis (CF) patients. METHODS: This was a retrospective cohort study involving patients 6-18 years of age, diagnosed with CF, and followed at a referral center between 2008 and 2010. We evaluated only those patients who were able to perform pulmonary function tests (PFTs). We analyzed FVC, FEV1, and FEF25-75%, expressed as percentages of the predicted values, prior to and after bronchodilator tests (pre-BD and post-BD, respectively), in 312 PFTs. Repeated measures ANOVA and multiple comparisons were used. RESULTS: The study included 56 patients, divided into two groups: those whose PFT results spanned the 2008-2010 period (n = 37); and those whose PFT results spanned only the 2009-2010 period (n = 19). In the 2008-2010 group, there were significant reductions in post-BD FEV1 between 2008 and 2010 (p = 0.028) and between 2009 and 2010 (p = 0.036), as was also the case for pre-BD and post-BD FEF25 75% in all multiple comparisons (2008 vs. 2009; 2008 vs. 2010; and 2009 vs. 2010). In the 2009-2010 group, there were no significant differences between any of the years for any of the variables studied. Among the 312 PFTs, significant responses to the bronchodilator occurred in only 24 (7.7%), all of which were from patients for whom no bronchodilator had been prescribed during the study period. CONCLUSIONS: In the CF patients studied, there was loss of pulmonary function, indicating progressive lung disease, over time. The changes were greater for FEF25-75% than for the other variables, which suggests the initial involvement of small airways. PMID:23503485
Escamilla, R; Pecoul, J; Hermant, C; Besombes, J P; Krempf, M
1992-01-01
Both intravenous drug addiction (IVDA) and HIV infection can involve respiratory system. So, we have studied pulmonary function in 107 heroin abusers during deprivation to clarify the extent of these two factors respectively. Two groups were separated: 50 subjects without HIV infection (HIV-) and 57 seropositive subjects (HIV+) in early stage of the disease (mean CD4 lymphocytes: 457 +/- 61/mm3). 36 subjects have been investigated 6 months later to evaluate the reversibility of possible observed abnormalities. Altered pulmonary function was encountered similarly in HIV+ and HIV-. DLco was abnormal in 40% of cases both in HIV+ (mean DLco: 63.4 +/- 1.1% of predicted values) and HIV- (mean DLco: 65.4 +/- 1.5% pred); obstructive lung disease was present in 18% of HIV- (FEV1/VC: 63.8 +/- 2.5) and 9% of HIV+ (FEV1/VC: 61 +/- 3.6); restrictive lung disease was found more frequently (16% vs 10%) in HIV+ (FEV1/VC: 81.2 +/- 2.1, TLC: 72.4 +/- 3.6% pred) than in HIV- (FEV1/VC: 84.2 +/- 1.6, TLC: 71.2 +/- 0.9% pred). These abnormalities were not associated with significant arterial blood gas modifications. As a whole, DLco tend to improve in the two groups and this significantly for HIV+ (p less than 0.03). But for individuals initial DLco alteration was persistent in 68% of cases suggesting slow improvement. In conclusion, in this study HIV+ and HIV- IVDA were not different concerning pulmonary function. In this risk group, DLco itself had a poor specificity and only it follow-up may be of interest for pulmonary opportunistic infection screening.
[Pulmonary function of children with acute leukemia in maintenance phase of chemotherapy].
de Macêdo, Thalita Medeiros Fernandes; Campos, Tania Fernandes; Mendes, Raquel Emanuele de França; França, Danielle Corrêa; Chaves, Gabriela Suéllen da Silva; de Mendonça, Karla Morganna Pereira Pinto
2014-12-01
The aim of this study was to assess the pulmonary function of children with acute leukemia. Cross-sectional observational analytical study that enrolled 34 children divided into groups A (17 with acute leukemia in the maintenance phase of chemotherapy) and B (17 healthy children). The groups were matched for sex, age and height. Spirometry was measured using a spirometer Microloop Viasys(®) in accordance with American Thoracic Society and European Respiratory Society guidelines. Maximal respiratory pressures were measured with an MVD300 digital manometer (Globalmed(®)). Maximal inspiratory pressures and maximal expiratory pressures were measured from residual volume and total lung capacity, respectively. Group A showed a significant decrease in maximal inspiratory pressures when compared to group B. No significant difference was found between the spirometric values of the two groups, nor was there any difference between maximal inspiratory pressure and maximal expiratory pressure values in group A compared to the lower limit values proposed as reference. Children with acute leukemia, myeloid or lymphoid, during the maintenance phase of chemotherapy exhibited unchanged spirometric variables and maximal expiratory pressure; However, there was a decrease in inspiratory muscle strength. Copyright © 2014 Associação de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.
Bellofiore, Alessandro; Chesler, Naomi C
2013-07-01
The right ventricle (RV) is a pulsatile pump, the efficiency of which depends on proper hemodynamic coupling with the compliant pulmonary circulation. The RV and pulmonary circulation exhibit structural and functional differences with the more extensively investigated left ventricle (LV) and systemic circulation. In light of these differences, metrics of LV function and efficiency of coupling to the systemic circulation cannot be used without modification to characterize RV function and efficiency of coupling to the pulmonary circulation. In this article, we review RV physiology and mechanics, established and novel methods for measuring RV function and hemodynamic coupling, and findings from application of these methods to RV function and coupling changes with pulmonary hypertension. We especially focus on non-invasive measurements, as these may represent the future for clinical monitoring of disease progression and the effect of drug therapies.
Wang, Yao; Shao, Wei-bo; Gao, Li; Lu, Jie; Gu, Hao; Sun, Li-hua; Tan, Yan; Zhang, Ying-dong
2014-01-01
There have been limited comparative data regarding the investigations on pulmonary and respiratory muscle function in the patients with different parkinsonism disorders such as Parkinson's disease (PD) and multiple system atrophy (MSA) versus normal elderly. The present study is aiming to characterize the performance of pulmonary function and respiratory muscle strength in PD and MSA, and to investigate the association with severity of motor symptoms and disease duration. Pulmonary function and respiratory muscle strength tests were performed in 30 patients with PD, 27 with MSA as well as in 20 age-, sex-, height-, weight-matched normal elderly controls. All the patients underwent United Parkinson's disease rating scale (UPDRS) or united multiple system atrophy rating scale (UMSARS) separately as diagnosed. Vital capacity, forced expiratory volume in 1 second and forced vital capacity decreased, residual volume and ratio of residual volume to total lung capacity increased in both PD and MSA groups compared to controls (p<0.05). Diffusing capacity was decreased in the MSA group, compared with PD and normal elderly control groups (p<0.05). Respiratory muscle strength was lower in both PD and MSA groups than in controls (p<0.05). The values representing spirometry function and respiratory muscle strength were found to have a negative linear correlation with mean score of UPDRS-III in PD and mean score of UMSARS-I in MSA. Respiratory muscle strength showed a negative linear correlation with the mean score of UMSARS-II and disease duration in MSA patients. These findings suggest that respiratory dysfunction is involved in PD and MSA. Respiratory muscle strength is remarkably reduced, and some of the parameters correlate with disease duration and illness severity. The compromised respiratory function in neurodegenerative disorders should be the focus of further researches.
Salisbury, Margaret L; Xia, Meng; Zhou, Yueren; Murray, Susan; Tayob, Nabihah; Brown, Kevin K; Wells, Athol U; Schmidt, Shelley L; Martinez, Fernando J; Flaherty, Kevin R
2016-02-01
Idiopathic pulmonary fibrosis is a progressive lung disease with variable course. The Gender-Age-Physiology (GAP) Index and staging system uses clinical variables to stage mortality risk. It is unknown whether clinical staging predicts future decline in pulmonary function. We assessed whether the GAP stage predicts future pulmonary function decline and whether interval pulmonary function change predicts mortality after accounting for stage. Patients with idiopathic pulmonary fibrosis (N = 657) were identified retrospectively at three tertiary referral centers, and baseline GAP stages were assessed. Mixed models were used to describe average trajectories of FVC and diffusing capacity of the lung for carbon monoxide (Dlco). Multivariable Cox proportional hazards models were used to assess whether declines in pulmonary function ≥ 10% in 6 months predict mortality after accounting for GAP stage. Over a 2-year period, GAP stage was not associated with differences in yearly lung function decline. After accounting for stage, a 10% decrease in FVC or Dlco over 6 months independently predicted death or transplantation (FVC hazard ratio, 1.37; Dlco hazard ratio, 1.30; both, P ≤ .03). Patients with GAP stage 2 with declining pulmonary function experienced a survival profile similar to patients with GAP stage 3, with 1-year event-free survival of 59.3% (95% CI, 49.4-67.8) vs 56.9% (95% CI, 42.2-69.1). Baseline GAP stage predicted death or lung transplantation but not the rate of future pulmonary function decline. After accounting for GAP stage, a decline of ≥ 10% over 6 months independently predicted death or lung transplantation. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Sansores, R; Perez-Padilla, R; Paré, P D; Selman, M
1992-05-01
Pigeon-breeder's lung (PBL) is extremely common in Mexico City and often progresses to irreversible pulmonary fibrosis. The exponential analysis of the lung pressure-volume (PV) curve (V = A - Be-kp) has been suggested as a method to separate the lung restriction caused by inflammation from that caused by pulmonary fibrosis; a significantly decreased value for the exponential constant, k, suggests a change in the mechanical properties of the functioning lung parenchyma, while a normal value accompanied by restriction suggests subtraction of lung units without a change in the mechanical properties of the functioning units. We measured lung volumes and static PV curves in 29 patients who had persistent lung restriction following a biopsy-proven diagnosis of PBL. Mean values in the 29 subjects were as follows: age, 43 +/- 13 years; TLC, 61 +/- 15 percent of predicted; VC, 46 +/- 19 percent of predicted; and k, 55 +/- 17 percent of predicted. Twenty-four of the 29 patients had values for k that were below the 95 percent confidence level, and five had "normal" values. There was no difference in TLC and VC (percent of predicted) between those with or without a decreased value for k. Four of five patients with a normal value for k improved subsequent to diagnosis, while only one of 21 patients with a decreased k improved. We conclude that increased lung elasticity manifested by a low value for k is common in patients with chronic PBL. These results support the observation of frequent irreversible lung fibrosis in these patients. Measurements of k could prove a good prognostic indicator at the time of initial diagnosis.
Soares, Ana Alice de Almeida; Barros, Camila Moraes; Santos, Cássia Giulliane Costa; Dos Santos, Maria Renata Aragão; Silva, José Rodrigo Santos; Silva Junior, Walderi Monteiro da; Simões, Silvia de Magalhães
2018-03-01
Rhinitis and asthma decrease quality of life. Few studies have assessed the performance of children with asthma or rhinitis under submaximal exercise. We evaluated maximal respiratory pressures, spirometric parameters, and ability to sustain submaximal exercise in these children before and after the 6-minute walk test (6MWT), compared to healthy children. This cross-sectional, analytical study included 89 children aged 6-12 years in outpatient follow-up: 27 healthy (H), 31 with rhinitis (R), and 31 with mild asthma under control (A). Pulmonary function parameters and maximal respiratory pressures were measured before and 5, 10, and 30 minutes after the 6MWT. Wilcoxon test was used to compare numerical numerical variables between two groups and analysis of variance or Kruskal-Wallis test for comparison among three groups. Total distance traveled in the 6MWT was similar among the three groups. Compared to pre-test values, VEF1 (Forced Expiratory Volume in 1 second), VEF0.75 (Forced Expiratory Volume in 0.75 second), and FEF25-75 (Forced Expiratory Flow 25-75% of the Forced Vital Capacity - CVF - curve) decreased significantly after the 6MWT in group A, and VEF0.75, FEF25-75, and VEF1/CVF decreased significantly in group R. Groups A and R had lower Maximum Inspiratory Pressure values than group H before and after the 6MWT at all time points assessed. The findings suggest that children with rhinitis and mild asthma present with alterations in respiratory muscle strength and pulmonary function not associated with clinical complaints, reinforcing the concept of the united airways.
Foppa, Murilo; Arora, Garima; Gona, Philimon; Ashrafi, Arman; Salton, Carol J; Yeon, Susan B; Blease, Susan J; Levy, Daniel; O'Donnell, Christopher J; Manning, Warren J; Chuang, Michael L
2016-03-01
Cardiac magnetic resonance is uniquely well suited for noninvasive imaging of the right ventricle. We sought to define normal cardiac magnetic resonance reference values and to identify the main determinants of right ventricular (RV) volumes and systolic function using a modern imaging sequence in a community-dwelling, longitudinally followed cohort free of clinical cardiovascular and pulmonary disease. The Framingham Heart Study Offspring cohort has been followed since 1971. We scanned 1794 Offspring cohort members using steady-state free precession cardiac magnetic resonance and identified a reference group of 1336 adults (64±9 years, 576 men) free of prevalent cardiovascular and pulmonary disease. RV trabeculations and papillary muscles were considered cavity volume. Men had greater RV volumes and cardiac output before and after indexation to body size (all P<0.001). Women had higher RV ejection fraction than men (68±6% versus 64±7%; P<0.0001). RV volumes and cardiac output decreased with advancing age. There was an increase in raw and height-indexed RV measurements with increasing body mass index, but this trend was weakly inverted after indexation of RV volumes to body surface area. Sex, age, height, body mass index, and heart rate account for most of the variability in RV volumes and function in this community-dwelling population. We report sex-specific normative values for RV measurements among principally middle-aged and older adults. RV ejection fraction is greater in women. RV volumes increase with body size, are greater in men, and are smaller in older people. Body surface area seems to be appropriate for indexation of cardiac magnetic resonance-derived RV volumes. © 2016 American Heart Association, Inc.
Chattopadhyay, B P; Alam, J; Roychowdhury, A
2003-01-01
In Kolkata city the road transports are maintained by private and Government organization. A major work force belonged to the State Transport Corporation (KSTC), Government of West-Bengal. The pollution caused by these vehicles affects the workers health and caused different types of respiratory problems. This study was undertaken to assess the pulmonary function status of these workers. City KSTC garage workers were investigated and categorically divided into two group: garage mechanics and the (2) those transporting the passengers (drivers and conductors). Vital capacity (VC), forced vital capacity (FVC) and peak expiratory flow rate (PEFR) were recorded by Spirovit-SP-10 (Schiller Ltd, Switzerland) and Wright's Peak Flow Meter (UK) on 236 workers. The different flow volumes, FEV(1), FEV(1%), and flow rates, FEF(02-121), FEF(25-75%), etc. were calculated. The administrative people had higher PFT than the other categories. Drivers and conductors have almost equal mean PFT values but mechanical workers had slightly higher. PFT values according to different age ranges and duration of exposure showed gradual decrement as age and duration of exposure increased. Non-smokers had higher lung volumes compared to smokers and ex-smokers. Restrictive, obstructive and combined types of impairments were noticed in 28.4%, 1.7% and 2.9%, respectively, workers. The restrictive impairment was found to be 30.4% in conductors; 28.9% in drivers, 27.9% in mechanics and 21.7% in administration people. Obstructive type of impairment was found to be 2.9% in both drivers and conductors. The effect of pollution by dust and fumes may be responsible for these pulmonary function impairments, restrictive impairments being greater.
Pulmonary Function in Children with Development Coordination Disorder
ERIC Educational Resources Information Center
Wu, Sheng K.; Cairney, John; Lin, Hsiao-Hui; Li, Yao-Chuen; Song, Tai-Fen
2011-01-01
The purpose of this study was to compare pulmonary function in children with developmental coordination disorder (DCD) with children who are typically developing (TD), and also analyze possible gender differences in pulmonary function between these groups. The Movement ABC test was used to identify the movement coordination ability of children.…
Boskabady, Mrteza; Boskabady, Mohammad Hossein; Zabihi, Narges Amel; Boskabady, Marzie
2015-01-01
Pulmonary complications due to mustard gas exposure range from no effect to severe bronchial stenosis. Pulmonary function tests (PFTs) and respiratory symptoms in chemical war victims were studied 23-25 years after exposure to sulfur mustard (SM). Respiratory symptoms were evaluated in a sample of 142 chemical war victims and 120 control subjects with similar age from the general population using a questionnaire including questions on respiratory symptoms in the past year. PFT values were also measured in chemical war victims before and 15 min after the inhalation of 200 µg salbutamol and baseline PFT in controls. All chemical war victims (100%) reported respiratory symptoms. Wheezing (66.19%), cough (64.78%), and chest tightness (54.4%) were the most common symptoms and only 15.5% of chemical war victims reported sputum (p < 0.01 for sputum and p < 0.001 for other symptoms compared with control group). In addition, 49.3% of chemical war victims had wheeze in chest examination, which were significantly higher than control group (p < 0.001). The severity of respiratory symptoms was also significantly higher than control subjects (p < 0.05 for sputum and p < 0.001 for other symptoms). All the PFT values were also significantly lower in chemical war victims than that in control subjects (p < 0.001 for all cases). In addition, all the PFT values improved significantly after the inhalation of 200 µg salbutamol (p < 0.05-p < 0.001). These results showed that chemical war victims, 23-25 years after exposure to chemical warfare have higher frequencies and severity of respiratory symptoms. PFT values were also significantly reduced among chemical war victims, which showed reversibility due to the inhalation of 200 µg salbutamol. © The Author(s) 2012.
Pulmonary gas exchange in acute respiratory failure.
Rodriguez-Roisin, R
1994-01-01
The principal function of the lung is to facilitate the exchange of the respiratory gases, oxygen (O2) and carbon dioxide (CO2). When the lung fails as a gas exchanger respiratory failure ensues. Clinically, it is generally accepted that an arterial oxygen tension (PaO2) of less than 60 mmHg or a PaCO2 of greater than 50 mmHg, or both, whilst breathing room air are values consistent with the concept of respiratory failure. This article will deal, firstly, with some basic aspects of the physiology of pulmonary gas exchange and more specifically on the measurement of ventilation-perfusion (VA/Q) relationships, the most influential factor determining hypoxaemia. The second part highlights the most important findings on pulmonary gas exchange in the adult respiratory distress syndrome (ARDS) and other common acute respiratory failure conditions, such as pneumonia, acute exacerbation of chronic obstructive pulmonary disease (COPD) and status asthmaticus, based on the data obtained by means of the multiple inert gas elimination approach, a technique which gives a detailed picture of VA/Q ratio distributions.
Pruning of the Pulmonary Vasculature in Asthma: The SARP Cohort.
Ash, Samuel Y; Rahaghi, Farbod N; Come, Carolyn E; Ross, James C; Colon, Alysha G; Cardet-Guisasola, Juan Carlos; Dunican, Eleanor M; Bleecker, Eugene R; Castro, Mario; Fahy, John V; Fain, Sean B; Gaston, Benjamin M; Hoffman, Eric A; Jarjour, Nizar N; Mauger, David T; Wenzel, Sally E; Levy, Bruce D; San Jose Estepar, Raul; Israel, Elliot; Washko, George R
2018-04-19
Loss of the peripheral pulmonary vasculature, termed vascular pruning, is associated with disease severity in patients with chronic obstructive pulmonary disease. To determine if pulmonary vascular pruning is associated with asthma severity and exacerbations. We measured the total pulmonary blood vessel volume (TBV) and the blood vessel volume of vessels less than 5mm2 in cross sectional area (BV5) and of vessels less than 10mm2 (BV10) in cross sectional area on non-contrast computed tomographic scans of participants from the Severe Asthma Research Program. Lower values of the BV5 to TBV ratio (BV5/TBV) and the BV10 to TBV ratio (BV10/TBV) represented vascular pruning (loss of the peripheral pulmonary vasculature). Compared to healthy controls, severe asthmatics had more pulmonary vascular pruning. Among asthmatics, those with poor asthma control had more pruning than those well-controlled disease. Pruning of the pulmonary vasculature was also associated with lower percent predicted forced expiratory volume in one second and forced vital capacity, greater peripheral and sputum eosinophilia and higher bronchoalveolar lavage SAA/LXA4, but not with low attenuation area or with sputum neutrophilia. Compared with individuals with less pruning, individuals with the most vascular pruning had a 150% greater odds of reporting an asthma exacerbation (OR 2.50; CI: 1.05, 5.98; p=0.039 for BV10/TBV), and reported 45% more asthma exacerbations during follow-up (IRR 1.45; CI: 1.02, 2.06; p=0.036 for BV10/TBV). Pruning of the peripheral pulmonary vasculature is associated with asthma severity, control and exacerbations, as well as with lung function and eosinophilia.
Amoozgar, Hamid; Zeighami, Samaneh; Haghpanah, Sezaneh; Karimi, Mehran
2017-01-01
The goal of this study was to compare heart function and arrhythmia in clinically asymptomatic patients with beta thalassemia intermedia and beta thalassemia major. In this cross-sectional study, 60 patients with beta thalassemia major and 60 patients with beta thalassemia intermedia who had clinically no symptoms of arrhythmia and clinically normal heart function were evaluated using 24-hour ambulatory electrocardiogram monitoring and echocardiography. For data analysis SPSS ver.20 software was used. A P-value of less than 0.05 was considered statistically significant. The mean age of the beta thalassemia intermedia patients was 24.18 ± 7.9 years and the mean age in beta thalassemia major was 24.38 ± 7.7 years (P>0.05). Premature atrial contractions (PACs) were observed in 14 (23.3%) patients with beta thalassemia intermedia and in 22 (36.6%) beta thalassemia major patients. Premature ventricular contractions (PVCs) were detected in 8 (13.3%) patients in the beta thalassemia intermediate group and 16 (26.6) patients in the beta thalassemia major group, respectively. The left ventricular diastolic dimension, end-diastolic volume, and stroke volume were significantly higher in beta thalassemia intermedia group (P<0.05). Pulmonary acceleration time as an indicator of pulmonary pressure was lower in beta thalassemia intermedia group. Both atrial and ventricular arrhythmias were more common in the beta thalassemia major group. Higher end-diastolic volume and stroke volume were detected in the beta thalassemia intermedia group. Pulmonary acceleration time was lower in the beta thalassemia intermedia group, which can be an indicator of higher pulmonary pressure.
Lee, Theresa M; Tu, Karen; Wing, Laura L; Gershon, Andrea S
2017-05-15
Little is known about using electronic medical records to identify patients with chronic obstructive pulmonary disease to improve quality of care. Our objective was to develop electronic medical record algorithms that can accurately identify patients with obstructive pulmonary disease. A retrospective chart abstraction study was conducted on data from the Electronic Medical Record Administrative data Linked Database (EMRALD ® ) housed at the Institute for Clinical Evaluative Sciences. Abstracted charts provided the reference standard based on available physician-diagnoses, chronic obstructive pulmonary disease-specific medications, smoking history and pulmonary function testing. Chronic obstructive pulmonary disease electronic medical record algorithms using combinations of terminology in the cumulative patient profile (CPP; problem list/past medical history), physician billing codes (chronic bronchitis/emphysema/other chronic obstructive pulmonary disease), and prescriptions, were tested against the reference standard. Sensitivity, specificity, and positive/negative predictive values (PPV/NPV) were calculated. There were 364 patients with chronic obstructive pulmonary disease identified in a 5889 randomly sampled cohort aged ≥ 35 years (prevalence = 6.2%). The electronic medical record algorithm consisting of ≥ 3 physician billing codes for chronic obstructive pulmonary disease per year; documentation in the CPP; tiotropium prescription; or ipratropium (or its formulations) prescription and a chronic obstructive pulmonary disease billing code had sensitivity of 76.9% (95% CI:72.2-81.2), specificity of 99.7% (99.5-99.8), PPV of 93.6% (90.3-96.1), and NPV of 98.5% (98.1-98.8). Electronic medical record algorithms can accurately identify patients with chronic obstructive pulmonary disease in primary care records. They can be used to enable further studies in practice patterns and chronic obstructive pulmonary disease management in primary care. NOVEL ALGORITHM SEARCH TECHNIQUE: Researchers develop an algorithm that can accurately search through electronic health records to find patients with chronic lung disease. Mining population-wide data for information on patients diagnosed and treated with chronic obstructive pulmonary disease (COPD) in primary care could help inform future healthcare and spending practices. Theresa Lee at the University of Toronto, Canada, and colleagues used an algorithm to search electronic medical records and identify patients with COPD from doctors' notes, prescriptions and symptom histories. They carefully adjusted the algorithm to improve sensitivity and predictive value by adding details such as specific medications, physician codes related to COPD, and different combinations of terminology in doctors' notes. The team accurately identified 364 patients with COPD in a randomly-selected cohort of 5889 people. Their results suggest opportunities for broader, informative studies of COPD in wider populations.
Burgos, Carmen Mesas; Davey, Marcus G; Riley, John S; Jia, Huimin; Flake, Alan W; Peranteau, William H
2017-12-19
Lung and pulmonary vascular maldevelopment in congenital diaphragmatic hernia (CDH) results in significant morbidity and mortality. Retinoic acid (RA) and imatinib have been shown to improve pulmonary morphology following prenatal administration in the rat nitrofen-induced CDH model. It remains unclear if these changes translate into improved function. We evaluated the effect of prenatal RA and imatinib on postnatal lung function, structure, and pulmonary artery (PA) blood flow in the rat CDH model. Olive oil or nitrofen was administered alone or in combination with RA or imatinib to pregnant rats. Pups were assessed for PA blood flow by ultrasound and pulmonary function/morphology following delivery, intubation, and short-term ventilation. Neither RA nor imatinib had a negative effect on lung and body growth. RA accelerated lung maturation indicated by increased alveoli number and thinner interalveolar septa and was associated with decreased PA resistance and improved oxygenation. With the exception of a decreased PA pulsatility index, no significant changes in morphology and pulmonary function were noted following imatinib. Prenatal treatment with RA but not imatinib was associated with improved pulmonary morphology and function, and decreased pulmonary vascular resistance. This study highlights the potential of prenatal pharmacologic therapies, such as RA, for management of CDH. Copyright © 2017 Elsevier Inc. All rights reserved.
Yoon, Hyun; Gi, Mi Young; Cha, Ju Ae; Yoo, Chan Uk; Park, Sang Muk
2018-03-01
This study assessed the association of metabolic syndrome and metabolic syndrome score with the predicted forced vital capacity and predicted forced expiratory volume in 1 s (predicted forced expiratory volume in 1 s) values in Korean non-smoking adults. We analysed data obtained from 6684 adults during the 2013-2015 Korean National Health and Nutrition Examination Survey. After adjustment for related variables, metabolic syndrome ( p < 0.001) and metabolic syndrome score ( p < 0.001) were found to be inversely associated with the predicted forced vital capacity and forced expiratory volume in 1 s values. The odds ratios of restrictive pulmonary disease (the predicted forced vital capacity < 80.0% with forced expiratory volume in 1 s/FVC ⩾ 70.0%) by metabolic syndrome score with metabolic syndrome score 0 as a reference group showed no significance for metabolic syndrome score 1 [1.061 (95% confidence interval, 0.755-1.490)] and metabolic syndrome score 2 [1.247 (95% confidence interval, 0.890-1.747)], but showed significant for metabolic syndrome score 3 [1.433 (95% confidence interval, 1.010-2.033)] and metabolic syndrome score ⩾ 4 [1.760 (95% confidence interval, 1.216-2.550)]. In addition, the odds ratio of restrictive pulmonary disease of the metabolic syndrome [1.360 (95% confidence interval, 1.118-1.655)] was significantly higher than those of non-metabolic syndrome. Metabolic syndrome and metabolic syndrome score were inversely associated with the predicted forced vital capacity and forced expiratory volume in 1 s values in Korean non-smoking adults. In addition, metabolic syndrome and metabolic syndrome score were positively associated with the restrictive pulmonary disease.
Classification Models for Pulmonary Function using Motion Analysis from Phone Sensors.
Cheng, Qian; Juen, Joshua; Bellam, Shashi; Fulara, Nicholas; Close, Deanna; Silverstein, Jonathan C; Schatz, Bruce
2016-01-01
Smartphones are ubiquitous, but it is unknown what physiological functions can be monitored at clinical quality. Pulmonary function is a standard measure of health status for cardiopulmonary patients. We have shown phone sensors can accurately measure walking patterns. Here we show that improved classification models can accurately measure pulmonary function, with sole inputs being sensor data from carried phones. Twenty-four cardiopulmonary patients performed six minute walk tests in pulmonary rehabilitation at a regional hospital. They carried smartphones running custom software recording phone motion. For every patient, every ten-second interval was correctly computed. The trained model perfectly computed the GOLD level 1/2/3, which is a standard categorization of pulmonary function as measured by spirometry. These results are encouraging towards field trials with passive monitors always running in the background. We expect patients can simply carry their phones during daily living, while supporting automatic computation ofpulmonary function for health monitoring.
Mujovic, Natasa; Mujovic, Nebojsa; Subotic, Dragan; Ercegovac, Maja; Milovanovic, Andjela; Nikcevic, Ljubica; Zugic, Vladimir; Nikolic, Dejan
2015-11-01
Influence of physiotherapy on the outcome of the lung resection is still controversial. Study aim was to assess the influence of physiotherapy program on postoperative lung function and effort tolerance in lung cancer patients with chronic obstructive pulmonary disease (COPD) that are undergoing lobectomy or pneumonectomy. The prospective study included 56 COPD patients who underwent lung resection for primary non small-cell lung cancer after previous physiotherapy (Group A) and 47 COPD patients (Group B) without physiotherapy before lung cancer surgery. In Group A, lung function and effort tolerance on admission were compared with the same parameters after preoperative physiotherapy. Both groups were compared in relation to lung function, effort tolerance and symptoms change after resection. In patients with tumors requiring a lobectomy, after preoperative physiotherapy, a highly significant increase in FEV1, VC, FEF50 and FEF25 of 20%, 17%, 18% and 16% respectively was registered with respect to baseline values. After physiotherapy, a significant improvement in 6-minute walking distance was achieved. After lung resection, the significant loss of FEV1 and VC occurred, together with significant worsening of the small airways function, effort tolerance and symptomatic status. After the surgery, a clear tendency existed towards smaller FEV1 loss in patients with moderate to severe, when compared to patients with mild baseline lung function impairment. A better FEV1 improvement was associated with more significant loss in FEV1. Physiotherapy represents an important part of preoperative and postoperative treatment in COPD patients undergoing a lung resection for primary lung cancer.
Pulmonary function and respiratory symptoms in potash workers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Graham, B.L.; Dosman, J.A.; Cotton, D.J.
1984-03-01
Over 94% of the workers in each of four Saskatchewan potash mines participated in a respiratory health surveillance program that included a questionnaire and pulmonary function tests. Compared with a nonexposed control group, potash workers had higher prevalences of cough, dyspnea, and chronic bronchitis but better pulmonary function. Prevalences of symptoms and pulmonary function abnormalities were similar among workers at the four mines tested and at the various job locations. Potash dust, diesel fumes, and other air contaminants may have an irritant effect that leads to the increased prevalences of cough and chronic bronchitis. Although no adverse effects of themore » potash mine environment on pulmonary function were found, these findings reflect a healthy worker effect or some selection process that makes the potash workers appear healthier in a cross-sectional study.« less
Pulmonary function and respiratory symptoms in potash workers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Graham, B.L.; Dosman, J.A.; Cotton, D.J.
1984-03-01
Over 94% of the workers in each of four Saskatchewan potash mines participated in a respiratory health surveillance program that included a questionnaire and pulmonary function tests. Compared with a nonexposed control group, potash workers had higher prevalences of cough, dyspnea, and chronic bronchitis but better pulmonary function. Prevalences of symptoms and pulmonary function abnormalities were similar among workers at the four mines tested and at the various job locations. Potash dust, diesel fumes, and other air contaminants may have an irritant effect that leads to the increased prevalences of cough and chronic bronchitis. Although we found no adverse effectsmore » of the potash mine environment on pulmonary function, these findings reflect a healthy worker effect or some selection process that makes the potash workers appear healthier in a cross-sectional study.« less
Sokalskis, Vladislavs; Peluso, Diletta; Jagodzinski, Annika; Sinning, Christoph
2017-06-01
Right heart dysfunction has been found to be a strong prognostic factor predicting adverse outcome in various cardiopulmonary diseases. Conventional echocardiographic measurements can be limited by geometrical assumptions and impaired reproducibility. Speckle tracking-derived strain provides a robust quantification of right ventricular function. It explicitly evaluates myocardial deformation, as opposed to tissue Doppler-derived strain, which is computed from tissue velocity gradients. Right ventricular longitudinal strain provides a sensitive tool for detecting right ventricular dysfunction, even at subclinical levels. Moreover, the longitudinal strain can be applied for prognostic stratification of patients with pulmonary hypertension, pulmonary embolism, and congestive heart failure. Speckle tracking-derived right atrial strain, right ventricular longitudinal strain-derived mechanical dyssynchrony, and three-dimensional echocardiography-derived strain are emerging imaging parameters and methods. Their application in research is paving the way for their clinical use. © 2017, Wiley Periodicals, Inc.
Wolff, R K; Obminski, G; Newhouse, M T
1984-01-01
Nine steel workers participated in controlled exposures to sulphur dioxide alone and sulphur dioxide plus carbon dust (5 ppm and 10 mg/m3, respectively). All were experiencing work related respiratory difficulties. Bronchial clearance was measured using radioaerosol inhalations and external detection. Results were variable and no statistically significant changes were observed. One asthmatic showed a complete cessation of clearance during exposure to sulphur dioxide and carbon dust. Bronchial reactivity was found to be significantly raised after exposure to sulphur dioxide but equivocal results were found after exposure to sulphur dioxide and carbon dust. Pronounced changes in pulmonary function were seen only in the two asthmatic subjects. They could not tolerate the levels, indicating that these threshold limit values are too high, at least for these individuals who showed much greater sensitivity to the pollutants than the others. PMID:6498113
Lechtzin, N; West, N; Allgood, S; Wilhelm, E; Khan, U; Mayer-Hamblett, N; Aitken, M L; Ramsey, B W; Boyle, M P; Mogayzel, P J; Goss, C H
2013-11-01
Acute pulmonary exacerbations are central events in the lives of individuals with cystic fibrosis (CF). Pulmonary exacerbations lead to impaired lung function, worse quality of life, and shorter survival. We hypothesized that aggressive early treatment of acute pulmonary exacerbation may improve clinical outcomes. Describe the rationale of an ongoing trial designed to determine the efficacy of home monitoring of both lung function measurements and symptoms for early detection and subsequent early treatment of acute CF pulmonary exacerbations. A randomized, non-blinded, multi-center trial in 320 individuals with CF aged 14 years and older. The study compares usual care to a twice a week assessment of home spirometry and CF respiratory symptoms using an electronic device with data transmission to the research personnel to identify and trigger early treatment of CF pulmonary exacerbation. Participants will be enrolled in the study for 12 months. The primary endpoint is change in FEV1 (L) from baseline to 12 months determined by a linear mixed effects model incorporating all quarterly FEV1 measurements. Secondary endpoints include time to first acute protocol-defined pulmonary exacerbation, number of acute pulmonary exacerbations, number of hospitalization days for acute pulmonary exacerbation, time from the end of acute pulmonary exacerbation to onset of subsequent pulmonary exacerbation, change in health related quality of life, change in treatment burden, change in CF respiratory symptoms, and adherence to the study protocol. This study is a first step in establishing alternative approaches to the care of CF pulmonary exacerbations. We hypothesize that early treatment of pulmonary exacerbations has the potential to slow lung function decline, reduce respiratory symptoms and improve the quality of life for individuals with CF. © 2013.
The Relationship of Welding Fume Exposure, Smoking, and Pulmonary Function in Welders.
Roach, Laura L
2018-01-01
The purpose of this study was to explore the relationship between occupational exposure to welding fumes and pulmonary function in an effort to add supportive evidence and clarity to the current body of research. This study utilized a retrospective chart review of pulmonary function testing and pulmonary questionnaires already available in charts from preplacement physicals to the most recent test. When comparing smokers to nonsmokers, utilizing multiple regression and controlling for age and percentage of time using a respirator, years welding was statistically significant at p = .04. Data support that smoking has a synergistic effect when combined with welding fume exposure on pulmonary decline.
Badyda, Artur; Gayer, Anna; Czechowski, Piotr Oskar; Majewski, Grzegorz; Dąbrowiecki, Piotr
2016-11-22
It is essential in pulmonary disease research to take into account traffic-related air pollutant exposure among urban inhabitants. In our study, 4985 people were examined for spirometric parameters in the presented research which was conducted in the years 2008-2012. The research group was divided into urban and rural residents. Traffic density, traffic structure and velocity, as well as concentrations of selected air pollutants (CO, NO₂ and PM 10 ) were measured at selected areas. Among people who live in the city, lower percentages of predicted values of spirometric parameters were noticed in comparison to residents of rural areas. Taking into account that the difference in the five-year mean concentration of PM 10 in the considered city and rural areas was over 17 μg/m³, each increase of PM 10 by 10 μg/m³ is associated with the decline in FEV₁ (forced expiratory volume during the first second of expiration) by 1.68%. These findings demonstrate that traffic-related air pollutants may have a significant influence on the decline of pulmonary function and the growing rate of respiratory diseases.
Badyda, Artur; Gayer, Anna; Czechowski, Piotr Oskar; Majewski, Grzegorz; Dąbrowiecki, Piotr
2016-01-01
It is essential in pulmonary disease research to take into account traffic-related air pollutant exposure among urban inhabitants. In our study, 4985 people were examined for spirometric parameters in the presented research which was conducted in the years 2008–2012. The research group was divided into urban and rural residents. Traffic density, traffic structure and velocity, as well as concentrations of selected air pollutants (CO, NO2 and PM10) were measured at selected areas. Among people who live in the city, lower percentages of predicted values of spirometric parameters were noticed in comparison to residents of rural areas. Taking into account that the difference in the five-year mean concentration of PM10 in the considered city and rural areas was over 17 μg/m3, each increase of PM10 by 10 μg/m3 is associated with the decline in FEV1 (forced expiratory volume during the first second of expiration) by 1.68%. These findings demonstrate that traffic-related air pollutants may have a significant influence on the decline of pulmonary function and the growing rate of respiratory diseases. PMID:27879677
Respiratory complications in the postanesthesia care unit: A review of pathophysiological mechanisms
Karcz, Marcin; Papadakos, Peter J
2013-01-01
General anesthesia and mechanical ventilation impair pulmonary function, even in normal individuals, and result in decreased oxygenation in the postanesthesia period. They also cause a reduction in functional residual capacity of up to 50% of the preanesthesia value. It has been shown that pulmonary atelectasis is a common finding in anesthetized individuals because it occurs in 85% to 90% of healthy adults. Furthermore, there is substantial evidence that atelectasis, in combination with alveolar hypoventilation and ventilation-perfusion mismatch, is the core mechanism responsible for postoperative hypoxemic events in the majority of patients in the postanesthesia care unit (PACU). Many concomitant factors also must be considered, such as respiratory depression from the type and anatomical site of surgery altering lung mechanics, the consequences of hemodynamic impairment and the residual effects of anesthetic drugs, most notably residual neuromuscular blockade. The appropriate use of anesthetic and analgesic techniques, when combined with meticulous postoperative care, clearly influences pulmonary outcomes in the PACU. The present review emphasizes the major pathophysiological mechanisms and treatment strategies of critical respiratory events in the PACU to provide health care workers with the knowledge needed to prevent such potentially adverse outcomes from occurring. PMID:26078599
Menon, Prahlad G; Adhypak, Srilakshmi M; Williams, Ronald B; Doyle, Mark; Biederman, Robert WW
2014-01-01
BACKGROUND We test the hypothesis that cardiac magnetic resonance (CMR) imaging-based indices of four-dimensional (4D) (three dimensions (3D) + time) right ventricle (RV) function have predictive values in ascertaining invasive pulmonary arterial systolic pressure (PASP) measurements from right heart catheterization (RHC) in patients with pulmonary arterial hypertension (PAH). METHODS We studied five patients with idiopathic PAH and two age and sex-matched controls for RV function using a novel contractility index (CI) for amplitude and phase to peak contraction established from analysis of regional shape variation in the RV endocardium over 20 cardiac phases, segmented from CMR images in multiple orientations. RESULTS The amplitude of RV contractility correlated inversely with RV ejection fraction (RVEF; R2 = 0.64, P = 0.03) and PASP (R2 = 0.71, P = 0.02). Phase of peak RV contractility also correlated inversely to RVEF (R2 = 0.499, P = 0.12) and PASP (R2 = 0.66, P = 0.04). CONCLUSIONS RV contractility analyzed from CMR offers promising non-invasive metrics for classification of PAH, which are congruent with invasive pressure measurements. PMID:25624777
Ergün, Recai; Evcik, Ender; Ergün, Dilek; Ergan, Begüm; Özkan, Esin; Gündüz, Özge
2017-05-05
The number of studies where non-malignant pulmonary diseases are evaluated after occupational arsenic exposure is very few. To investigate the effects of occupational arsenic exposure on the lung by high-resolution computed tomography and pulmonary function tests. Retrospective cross-sectional study. In this study, 256 workers with suspected respiratory occupational arsenic exposure were included, with an average age of 32.9±7.8 years and an average of 3.5±2.7 working years. Hair and urinary arsenic levels were analysed. High-resolution computed tomography and pulmonary function tests were done. In workers with occupational arsenic exposure, high-resolution computed tomography showed 18.8% pulmonary involvement. In pulmonary involvement, pulmonary nodule was the most frequently seen lesion (64.5%). The other findings of pulmonary involvement were 18.8% diffuse interstitial lung disease, 12.5% bronchiectasis, and 27.1% bullae-emphysema. The mean age of patients with pulmonary involvement was higher and as they smoked more. The pulmonary involvement was 5.2 times higher in patients with skin lesions because of arsenic. Diffusing capacity of lung for carbon monoxide was significantly lower in patients with pulmonary involvement. Besides lung cancer, chronic occupational inhalation of arsenic exposure may cause non-malignant pulmonary findings such as bronchiectasis, pulmonary nodules and diffuse interstitial lung disease. So, in order to detect pulmonary involvement in the early stages, workers who experience occupational arsenic exposure should be followed by diffusion test and high-resolution computed tomography.
Kumar, Amaravadi Sampath; Alaparthi, Gopala Krishna; Augustine, Alfred Joseph; Pazhyaottayil, Zulfeequer Chundaanveetil; Ramakrishna, Anand; Krishnakumar, Shyam Krishnan
2016-01-01
Surgical procedures in abdominal area lead to changes in pulmonary function, respiratory mechanics and impaired physical capacity leading to postoperative pulmonary complications, which can affect up to 80% of upper abdominal surgery. To evaluate the effects of flow and volume incentive spirometry on pulmonary function and exercise tolerance in patients undergoing open abdominal surgery. A randomized clinical trial was conducted in a hospital of Mangalore city in Southern India. Thirty-seven males and thirteen females who were undergoing abdominal surgeries were included and allocated into flow and volume incentive spirometry groups by block randomization. All subjects underwent evaluations of pulmonary function with measurement of Forced Vital Capacity (FVC), Forced Expiratory Volume in the first second (FEV1), Peak Expiratory Flow (PEF). Preoperative and postoperative measurements were taken up to day 5 for both groups. Exercise tolerance measured by Six- Minute Walk Test during preoperative period and measured again at the time of discharge for both groups. Pulmonary function was analysed by post-hoc analysis and carried out using Bonferroni's 't'-test. Exercise tolerance was analysed by Paired 'T'-test. Pulmonary function (FVC, FEV1, and PEFR) was found to be significantly decreased in 1(st), 2(nd) and 3(rd) postoperative day when compared with preoperative day. On 4(th) and 5(th) postoperative day the pulmonary function (FVC, FEV1, and PEFR) was found to be better preserved in both flow and volume incentive spirometry groups. The Six-Minute Walk Test showed a statistically significant improvement in pulmonary function on the day of discharge than in the preoperative period. In terms of distance covered, the volume- incentive spirometry group showed a greater statistically significant improvement from the preoperative period to the time of discharge than was exhibited by the flow incentive spirometry group. Flow and volume incentive spirometry can be safely recommended to patients undergoing open abdominal surgery as there have been no adverse events recorded. Also, these led to a demonstrable improvement in pulmonary function and exercise tolerance.
Kumar, Amaravadi Sampath; Augustine, Alfred Joseph; Pazhyaottayil, Zulfeequer Chundaanveetil; Ramakrishna, Anand; Krishnakumar, Shyam Krishnan
2016-01-01
Introduction Surgical procedures in abdominal area lead to changes in pulmonary function, respiratory mechanics and impaired physical capacity leading to postoperative pulmonary complications, which can affect up to 80% of upper abdominal surgery. Aim To evaluate the effects of flow and volume incentive spirometry on pulmonary function and exercise tolerance in patients undergoing open abdominal surgery. Materials and Methods A randomized clinical trial was conducted in a hospital of Mangalore city in Southern India. Thirty-seven males and thirteen females who were undergoing abdominal surgeries were included and allocated into flow and volume incentive spirometry groups by block randomization. All subjects underwent evaluations of pulmonary function with measurement of Forced Vital Capacity (FVC), Forced Expiratory Volume in the first second (FEV1), Peak Expiratory Flow (PEF). Preoperative and postoperative measurements were taken up to day 5 for both groups. Exercise tolerance measured by Six- Minute Walk Test during preoperative period and measured again at the time of discharge for both groups. Pulmonary function was analysed by post-hoc analysis and carried out using Bonferroni’s ‘t’-test. Exercise tolerance was analysed by Paired ‘T’-test. Results Pulmonary function (FVC, FEV1, and PEFR) was found to be significantly decreased in 1st, 2nd and 3rd postoperative day when compared with preoperative day. On 4th and 5th postoperative day the pulmonary function (FVC, FEV1, and PEFR) was found to be better preserved in both flow and volume incentive spirometry groups. The Six-Minute Walk Test showed a statistically significant improvement in pulmonary function on the day of discharge than in the preoperative period. In terms of distance covered, the volume- incentive spirometry group showed a greater statistically significant improvement from the preoperative period to the time of discharge than was exhibited by the flow incentive spirometry group. Conclusion Flow and volume incentive spirometry can be safely recommended to patients undergoing open abdominal surgery as there have been no adverse events recorded. Also, these led to a demonstrable improvement in pulmonary function and exercise tolerance. PMID:26894090
Decrease in pulmonary function and oxygenation after lung resection
Westerdahl, Elisabeth; Langer, Daniel; Souza, Domingos S.R.; Andreasen, Jan Jesper
2018-01-01
Respiratory deficits are common following curative intent lung cancer surgery and may reduce the patient's ability to be physically active. We evaluated the influence of surgery on pulmonary function, respiratory muscle strength and physical performance after lung resection. Pulmonary function, respiratory muscle strength (maximal inspiratory/expiratory pressure) and 6-min walk test (6MWT) were assessed pre-operatively, 2 weeks post-operatively and 6 months post-operatively in 80 patients (age 68±9 years). Video-assisted thoracoscopic surgery was performed in 58% of cases. Two weeks post-operatively, we found a significant decline in pulmonary function (forced vital capacity −0.6±0.6 L and forced expiratory volume in 1 s −0.43±0.4 L; both p<0.0001), 6MWT (−37.6±74.8 m; p<0.0001) and oxygenation (−2.9±4.7 units; p<0.001), while maximal inspiratory and maximal expiratory pressure were unaffected. At 6 months post-operatively, pulmonary function and oxygenation remained significantly decreased (p<0.001), whereas 6MWT was recovered. We conclude that lung resection has a significant short- and long-term impact on pulmonary function and oxygenation, but not on respiratory muscle strength. Future research should focus on mechanisms negatively influencing post-operative pulmonary function other than impaired respiratory muscle strength. PMID:29362707
Decrease in pulmonary function and oxygenation after lung resection.
Brocki, Barbara Cristina; Westerdahl, Elisabeth; Langer, Daniel; Souza, Domingos S R; Andreasen, Jan Jesper
2018-01-01
Respiratory deficits are common following curative intent lung cancer surgery and may reduce the patient's ability to be physically active. We evaluated the influence of surgery on pulmonary function, respiratory muscle strength and physical performance after lung resection. Pulmonary function, respiratory muscle strength (maximal inspiratory/expiratory pressure) and 6-min walk test (6MWT) were assessed pre-operatively, 2 weeks post-operatively and 6 months post-operatively in 80 patients (age 68±9 years). Video-assisted thoracoscopic surgery was performed in 58% of cases. Two weeks post-operatively, we found a significant decline in pulmonary function (forced vital capacity -0.6±0.6 L and forced expiratory volume in 1 s -0.43±0.4 L; both p<0.0001), 6MWT (-37.6±74.8 m; p<0.0001) and oxygenation (-2.9±4.7 units; p<0.001), while maximal inspiratory and maximal expiratory pressure were unaffected. At 6 months post-operatively, pulmonary function and oxygenation remained significantly decreased (p<0.001), whereas 6MWT was recovered. We conclude that lung resection has a significant short- and long-term impact on pulmonary function and oxygenation, but not on respiratory muscle strength. Future research should focus on mechanisms negatively influencing post-operative pulmonary function other than impaired respiratory muscle strength.
Moore, Jonathan P; Hainsworth, Roger; Drinkhill, Mark J
2004-01-01
We investigated whether the reflex responses to stimulation of pulmonary arterial baroreceptors were altered by intrathoracic pressure changes similar to those encountered during normal breathing. Dogs were anaesthetized with α-chloralose, a cardiopulmonary bypass was established, and the pulmonary trunk and its main branches as far as the first lobar arteries were vascularly isolated and perfused with venous blood. The chest was closed following connection to the perfusion circuit and pressures distending the aortic arch, carotid sinus and coronary artery baroreceptors were controlled. Changes in the descending aortic (systemic) perfusion pressure (SPP; flow constant) were used to assess changes in systemic vascular resistance. Values of SPP were plotted against mean pulmonary arterial pressure (PAP) and sigmoid functions applied. From these curves we derived the threshold pressures (corresponding to 5% of the overall response of SPP), the maximum slopes (equivalent to peak gain) and the corresponding PAP (equivalent to ‘set point’). Stimulus–response curves were compared between data obtained with intrathoracic pressure at atmospheric and with a phasic intrathoracic pressure ranging from atmospheric to around −10 mmHg (18 cycles min−1). Results were obtained from seven dogs and are given as means ±s.e.m. Compared to the values obtained when intrathoracic pressure was at atmospheric, the phasic intrathoracic pressure decreased the pulmonary arterial threshold pressure in five dogs; average change from 28.4 ± 5.9 to 19.3 ± 5.9 mmHg (P > 0.05). The inflexion pressure was significantly reduced from 37.8 ± 4.8 to 27.4 ± 4.0 mmHg (P < 0.03), but the slopes of the curves were not consistently changed. These results have shown that a phasic intrathoracic pressure, which simulates respiratory oscillations, displaces the stimulus–response curve of the pulmonary arterial baroreceptors to lower pressures so that it lies within a physiological range of pressures. PMID:14724182
Pressure-Flow During Exercise Catheterization Predicts Survival in Pulmonary Hypertension.
Hasler, Elisabeth D; Müller-Mottet, Séverine; Furian, Michael; Saxer, Stéphanie; Huber, Lars C; Maggiorini, Marco; Speich, Rudolf; Bloch, Konrad E; Ulrich, Silvia
2016-07-01
Pulmonary hypertension manifests with impaired exercise capacity. Our aim was to investigate whether the mean pulmonary arterial pressure to cardiac output relationship (mPAP/CO) predicts transplant-free survival in patients with pulmonary arterial hypertension (PAH) and inoperable chronic thromboembolic pulmonary hypertension (CTEPH). Hemodynamic data according to right heart catheterization in patients with PAH and CTEPH at rest and during supine incremental cycle exercise were analyzed. Transplant-free survival and predictive value of hemodynamics were assessed by using Kaplan-Meier and Cox regression analyses. Seventy patients (43 female; 54 with PAH, 16 with CTEPH; median (quartiles) age, 65 [50; 73] years; mPAP, 34 [29; 44] mm Hg; cardiac index, 2.8 [2.3; 3.5] [L/min]/m(2)) were followed up for 610 (251; 1256) days. Survival at 1, 3, 5, and 7 years was 89%, 81%, 71%, and 59%. Age, World Health Organization-functional class, 6-min walk test, and mixed-venous oxygen saturation (but not resting hemodynamics) predicted transplant-free survival. Maximal workload (hazard ratio [HR], 0.94 [95% CI, 0.89-0.99]; P = .027), peak cardiac index (HR, 0.51 [95% CI, 0.27-0.95]; P = .034), change in cardiac index, 0.25 [95% CI, 0.06-0.94]; P = .040), and mPAP/CO (HR, 1.02 [95% CI, 1.01-1.03]; P = .003) during exercise predicted survival. Values for mPAP/CO predicted 3-year transplant-free survival with an area under the curve of 0.802 (95% CI, 0.66-0.95; P = .004). In this collective of patients with PAH or CTEPH, the pressure-flow relationship during exercise predicted transplant-free survival and correlated with established markers of disease severity and outcome. Right heart catheterization during exercise may provide important complementary prognostic information in the management of pulmonary hypertension. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Miller, Albert; Warshaw, Raphael; Nezamis, James
2013-12-01
Asbestosis is an interstitial lung disease whose radiographic severity has long been graded by the International Labour Office (ILO) profusion score. Its effect on pulmonary function is further impacted by asbestos related pleural thickening. This report aims to describe the relationships between radiographic grading of interstitial and pleural fibrosis and a key test of pulmonary function, the diffusing capacity, which measures gas exchange and has rarely been assessed in large groups, and to confirm the relationship to an independent test of pulmonary function, the vital capacity, which measures a mechanical property of the lungs. The data were derived from a survey during the period 1997-2004 of 5,003 workers (all white males) exposed to asbestos in various trades. Tests included chest radiographs read by a certified expert ("B") reader, forced vital capacity (FVC), and carbon monoxide diffusing capacity (DLco). Cigarette smoking was adjusted for in the predictive equation for DLCO . Workers were evaluated at a mobile facility at work sites in four southern states. Both diffusing capacity and vital capacity were negatively correlated with profusion score over the full spectrum of radiographic severity. ILO profusion scores 0/1 (conventionally classified as normal) and 1/0 (conventionally classified as abnormal) were associated with similar diffusing capacity and vital capacity values. The highest profusion scores were associated with a greater proportionate decrease in diffusing capacity than in FVC. Both tests showed an effect of pleural fibrosis. Both radiographic severity graded by the profusion score and pleural thickening are correlated with two independent measures of pulmonary function. FVC (which had been reported in smaller work forces) and DLCO (which has not been reported). Both measures show a decrease from normal to intermediate (0/1, 1/0) scores and a further decrease with greater scores, demonstrating the consistency of radiographic and functional assessments. © 2013 Wiley Periodicals, Inc.
Zhang, Lan; Lü, Lei; Wu, Hua-wei; Zhang, Hao; Zhang, Ji-wei
2011-12-06
To present our initial experiences with pulmonary high-definition multidetector computed tomography (HDCT) in patients with acute venous thromboembolism (AVTE) to evaluate their corresponding clinical manifestations. Since December 2009 to March 2010, 23 AVTE patients underwent HDCT at our hospital. Pulmonary embolism (PE) was diagnosed based on the 3D-reconstructed images of computed tomography pulmonary angiography (CTPA). The post processed data were collected by spectral imaging system software to detect the iodine distribution maps. Perfusion defects, calculated as the values of iodine content, were compared with those of normal lung parenchymal perfusion in the absence of PE. Among them, 14 AVTE patients were definitely diagnosed with PE. Prior to anticoagulant therapy, their values of iodine content in defective perfusion area were significantly lower than those in normal perfusion area. After a 3-month anticoagulant therapy, the values of iodine content for the defective perfusion area increased significantly (P < 0.05). There was no significant correlation between the values of iodine content for segmental/subsegmental filling defect area and clinical risk score of DVT (r = 2.68, P > 0.05). But there was a significant negative correlation between the values of iodine content for segmental/subsegmental filling defection area and clinical probability score of PE (r = 0.78, P < 0.05). HDCT is a promising modality of visualizing pulmonary microvasculature as a correlative manifestation of regional perfusion. PE results in hypoperfusion with decreased values of iodine content in affected lung parenchyma. Hemodynamic changes in affected areas correlate with the severity of clinical manifestations of PE.
Li, Yidan; Wang, Yidan; Li, Hong; Zhu, Weiwei; Meng, Xiangli; Lu, Xiuzhang
2017-01-01
The present study aimed to evaluate hemodynamics and right ventricular function in patients with pulmonary hypertension (PH) using transthoracic echocardiography and to compare these results with measurements obtained using right-sided heart catheterization (RHC). A total of 75 patients with PH were examined using echocardiography and RHC. Patients were divided into the following two groups according to their difference between SPAPecho and SPAPRHC measurement: The overestimated group and underestimated group. The overestimated group included the subgroups groupover-A (difference <20 mmHg) and groupover-B (difference ≥20 mmHg), and the underestimated group included groupunder-A (absolute value of the difference <20 mmHg) and groupunder-B (absolute value of the difference ≥20 mmHg). SPAPecho measurements were revealed to be significantly positively correlated with SPAPRHC measurements (r=0.794; P<0.01). Among all echocardiographic measurements, only tricuspid annular plane systolic excursion (TAPSE) was significantly different between groups; it was increased in groupover-A and groupunder-A compared with groupover-B (P<0.01). Although SPAP measurements obtained using echocardiography were significantly positively correlated with those obtained using RHC, a high proportion of overestimation or underestimation of SPAP by echocardiography remained. PMID:29042956
Prins, Kurt W; Tian, Lian; Wu, Danchen; Thenappan, Thenappan; Metzger, Joseph M; Archer, Stephen L
2017-05-31
Pulmonary arterial hypertension (PAH) is a lethal disease characterized by obstructive pulmonary vascular remodeling and right ventricular (RV) dysfunction. Although RV function predicts outcomes in PAH, mechanisms of RV dysfunction are poorly understood, and RV-targeted therapies are lacking. We hypothesized that in PAH, abnormal microtubular structure in RV cardiomyocytes impairs RV function by reducing junctophilin-2 (JPH2) expression, resulting in t-tubule derangements. Conversely, we assessed whether colchicine, a microtubule-depolymerizing agent, could increase JPH2 expression and enhance RV function in monocrotaline-induced PAH. Immunoblots, confocal microscopy, echocardiography, cardiac catheterization, and treadmill testing were used to examine colchicine's (0.5 mg/kg 3 times/week) effects on pulmonary hemodynamics, RV function, and functional capacity. Rats were treated with saline (n=28) or colchicine (n=24) for 3 weeks, beginning 1 week after monocrotaline (60 mg/kg, subcutaneous). In the monocrotaline RV, but not the left ventricle, microtubule density is increased, and JPH2 expression is reduced, with loss of t-tubule localization and t-tubule disarray. Colchicine reduces microtubule density, increases JPH2 expression, and improves t-tubule morphology in RV cardiomyocytes. Colchicine therapy diminishes RV hypertrophy, improves RV function, and enhances RV-pulmonary artery coupling. Colchicine reduces small pulmonary arteriolar thickness and improves pulmonary hemodynamics. Finally, colchicine increases exercise capacity. Monocrotaline-induced PAH causes RV-specific derangement of microtubules marked by reduction in JPH2 and t-tubule disarray. Colchicine reduces microtubule density, increases JPH2 expression, and improves both t-tubule architecture and RV function. Colchicine also reduces adverse pulmonary vascular remodeling. These results provide biological plausibility for a clinical trial to repurpose colchicine as a RV-directed therapy for PAH. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Yabuuchi, Hidetake; Kawanami, Satoshi; Kamitani, Takeshi; Yonezawa, Masato; Yamasaki, Yuzo; Yamanouchi, Torahiko; Nagao, Michinobu; Okamoto, Tatsuro; Honda, Hiroshi
2016-11-01
To compare the predictabilities of postoperative pulmonary function after lobectomy for primary lung cancer among counting method, effective lobar volume, and lobar collapsibility. Forty-nine patients who underwent lobectomy for primary lung cancer were enrolled. All patients underwent inspiratory/expiratory CT and pulmonary function tests 2 weeks before surgery and postoperative pulmonary function tests 6-7 months after surgery. Pulmonary function losses (ΔFEV 1.0 and ΔVC) were calculated from the pulmonary function tests. Predictive postoperative pulmonary function losses (ppoΔFEV 1.0 and ppoΔVC) were calculated using counting method, effective volume, and lobar collapsibility. Correlations and agreements between ΔFEV 1.0 and ppoFEV 1.0 and those between ΔVC and ppoΔVC were tested among three methods using Spearman's correlation coefficient and Bland-Altman plots. ΔFEV 1.0 and ppoΔFEV 1.0insp-exp were strongly correlated (r=0.72), whereas ΔFEV 1.0 and ppoΔFEV 1.0count and ΔFEV 1.0 and Pred. ΔFEV 1.0eff.vol. were moderately correlated (r=0.50, 0.56). ΔVC and ppoΔVC eff.vol. (r=0.71) were strongly correlated, whereas ΔVC and ppoΔVC count , and ΔVC and ppoΔVC insp-exp were moderately correlated (r=0.55, 0.42). Volumetry from inspiratory/expiratory CT data could be useful to predict postoperative pulmonary function after lobectomy for primary lung cancer. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Furlanetto, Karina C.; Pinto, Isabela F. S.; Sant’Anna, Thais; Hernandes, Nidia A.; Pitta, Fabio
2016-01-01
ABSTRACT Objective To compare the profiles of patients with chronic obstructive pulmonary disease (COPD) considered physically active or inactive according to different classifications of the level of physical activity in daily life (PADL). Method Pulmonary function, dyspnea, functional status, body composition, exercise capacity, respiratory and peripheral muscle strength, and presence of comorbidities were assessed in 104 patients with COPD. The level of PADL was quantified with a SenseWear Armband activity monitor. Three classifications were used to classify the patients as physically active or inactive: 30 minutes of activity/day with intensity >3.2 METs, if age ≥65 years, and >4 METs, if age <65 years; 30 minutes of activity/day with intensity >3.0 METs, regardless of patient age; and 80 minutes of activity/day with intensity >3.0 METs, regardless of patient age. Results In all classifications, when compared with the inactive group, the physically active group had better values of anthropometric variables (higher fat-free mass, lower body weight, body mass index and fat percentage), exercise capacity (6-minute walking distance), lung function (forced vital capacity) and functional status (personal care domain of the London Chest Activity of Daily Living). Furthermore, patients classified as physically active in two classifications also had better peripheral and expiratory muscle strength, airflow obstruction, functional status, and quality of life, as well as lower prevalence of heart disease and mortality risk. Conclusion In all classification methods, physically active patients with COPD have better exercise capacity, lung function, body composition, and functional status compared to physically inactive patients. PMID:27683835
Respiratory muscle function in patients with cystic fibrosis.
Dassios, Theodore; Katelari, Anna; Doudounakis, Stavros; Mantagos, Stefanos; Dimitriou, Gabriel
2013-09-01
Respiratory muscle function in patients with cystic fibrosis (CF) can be assessed by measurement of maximal inspiratory pressure (Pimax ), maximal expiratory pressure (Pemax ), and pressure-time index of the respiratory muscles (PTImus ). We investigated the differences in maximal respiratory pressures and PTImus between CF patients with no gross hyperinflation and healthy controls and described the effects of pulmonary function and nutrition impairment on respiratory muscle function in this group of CF patients. Forced expiratory volume in 1 sec (FEV1 ), forced vital capacity (FVC) and maximal expiratory flow between 25% and 75% of VC (MEF25-75 ), body mass index (BMI), upper arm muscle area (UAMA), Pimax , Pemax , and PTImus were assessed in 140 CF patients and in a control group of 140 healthy subjects matched for age and gender. Median Pimax and Pemax were significantly lower in CF patients compared to the controls [Pimax = 74 (57-94) in CF vs. 84 (66-102) in controls, P = 0.009], [Pemax = 71 (50-95) in CF vs. 84 (66-102) in controls, P < 0.001]. Median PTImus in CF patients compared to controls was significantly increased [PTImus = 0.110 (0.076-0.160) in CF vs. 0.094 (0.070-0.137) in controls, P = 0.049] and it was significantly higher in CF patients with impaired pulmonary function. In CF patients, PTImus was significantly negatively related to upper arm muscle area (r = 0.184, P = 0.031). These findings suggest that CF patients with no severe lung disease compared to healthy subjects exhibit impaired respiratory muscle function, while CF patients with impaired pulmonary function and nutrition indices exhibit higher PTImus values. Copyright © 2012 Wiley Periodicals, Inc.
Wei, Xia; Shi, Zhihong; Cui, Yajuan; Mi, Jiuyun; Ma, Zhengquan; Ren, Jingting; Li, Jie; Xu, Shudi; Guo, Youmin
2017-11-01
We aimed to compare impulse oscillation system (IOS) and traditional pulmonary function tests (PFTs) for the assessment of the severity of chronic obstructive pulmonary disease (COPD), and to assess the use of IOS parameters to identify patients who were forced expiratory volume in 1 second (FEV1)%pred < 50%.Patients with COPD (n = 215) were enrolled at the Ninth Hospital of Xi'an Affiliated Hospital of Xi'an Jiaotong University between October 2014 and September 2016. All patients were assessed by traditional PFT and IOS. Diagnostic performance of IOS parameters to determine indication for patients of FEV1%pred < 50% was assessed on receiver-operating characteristics (ROC) curve analysis.Out of 215 patients, 18, 83, 78, and 36 patients were classified as grade 1, 2, 3, and 4, respectively, according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD) severity grading. On Spearman correlation analysis, FEV1%pred, MMEF 75%-25%, and residual volume/total lung capacity (RV/TLC) correlated with total respiratory impedance (Z5)%pred, resistance at 5 Hz (R5)-resistance at 20 Hz (R20), R5-R20% R5, R5, R5%pred, frequency response (Fres), reactance area (Ax), and reactance at 5 Hz (X5). On ROC curve analysis, the area under the curve (AUC) of X5 absolute value, Fres, Ax, Z5%pred, R5-R20, and R5-R20% R5 were 0.748, 0.755, 0.760, 0.705, 0.715, and 0.735, respectively, for COPD patients who required inhalational glucocorticoid therapy.IOS parameters showed a good correlation with traditional pulmonary function parameters; reactance parameters showed a stronger correlation than that of the resistance parameters. IOS can be used as an alternative method for pulmonary function assessment in patients with COPD with FEV1%pred < 50% who need inhalational glucocorticoid therapy. ChiCTR-OCH-14004904.
Wei, Xia; Shi, Zhihong; Cui, Yajuan; Mi, Jiuyun; Ma, Zhengquan; Ren, Jingting; Li, Jie; Xu, Shudi; Guo, Youmin
2017-01-01
Abstract We aimed to compare impulse oscillation system (IOS) and traditional pulmonary function tests (PFTs) for the assessment of the severity of chronic obstructive pulmonary disease (COPD), and to assess the use of IOS parameters to identify patients who were forced expiratory volume in 1 second (FEV1)%pred < 50%. Patients with COPD (n = 215) were enrolled at the Ninth Hospital of Xi’an Affiliated Hospital of Xi’an Jiaotong University between October 2014 and September 2016. All patients were assessed by traditional PFT and IOS. Diagnostic performance of IOS parameters to determine indication for patients of FEV1%pred < 50% was assessed on receiver-operating characteristics (ROC) curve analysis. Out of 215 patients, 18, 83, 78, and 36 patients were classified as grade 1, 2, 3, and 4, respectively, according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD) severity grading. On Spearman correlation analysis, FEV1%pred, MMEF 75%–25%, and residual volume/total lung capacity (RV/TLC) correlated with total respiratory impedance (Z5)%pred, resistance at 5 Hz (R5)-resistance at 20 Hz (R20), R5-R20% R5, R5, R5%pred, frequency response (Fres), reactance area (Ax), and reactance at 5 Hz (X5). On ROC curve analysis, the area under the curve (AUC) of X5 absolute value, Fres, Ax, Z5%pred, R5-R20, and R5-R20% R5 were 0.748, 0.755, 0.760, 0.705, 0.715, and 0.735, respectively, for COPD patients who required inhalational glucocorticoid therapy. IOS parameters showed a good correlation with traditional pulmonary function parameters; reactance parameters showed a stronger correlation than that of the resistance parameters. IOS can be used as an alternative method for pulmonary function assessment in patients with COPD with FEV1%pred < 50% who need inhalational glucocorticoid therapy. Clinical trial registration number: ChiCTR-OCH-14004904. PMID:29145259
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bergin, C.J.; Bell, D.Y.; Coblentz, C.L.
1989-06-01
The appearances of the lungs on radiographs and computed tomographic (CT) scans were correlated with degree of uptake on gallium scans and results of pulmonary function tests (PFTs) in 27 patients with sarcoidosis. CT scans were evaluated both qualitatively and quantitatively. Patients were divided into five categories on the basis of the pattern of abnormality at CT: 1 = normal (n = 4); 2 = segmental air-space disease (n = 4); 3 = spherical (alveolar) masslike opacities (n = 4); 4 = multiple, discrete, small nodules (n = 6); and 5 = distortion of parenchymal structures (fibrotic end-stage sarcoidosis) (nmore » = 9). The percentage of the volume judged to be abnormal (CT grade) was correlated with PFT results for each CT and radiographic category. CT grades were also correlated with gallium scanning results and percentage of lymphocytes recovered from bronchoalveolar lavage (BAL). Patients in CT categories 1 and 2 had normal lung function, those in category 3 had mild functional impairment, and those in categories 4 and 5 showed moderate to severe dysfunction. The overall CT grade correlated well with PFT results expressed as a percentage of the predicted value. In five patients, CT scans showed extensive parenchymal disease not seen on radiographs. CT grades did not correlate with the results of gallium scanning or BAL lymphocytes. The authors conclude that patterns of parenchymal sarcoidosis seen at CT correlate with the PFT results and can be used to indicate respiratory impairment.« less
Increased systemic vascular resistance in neonates with pulmonary hypertension.
Milstein, J M; Goetzman, B W; Riemenschneider, T A; Wennberg, R P
1979-11-01
The time necessary for aortic diastolic pressure to decrease to 50 percent of an initially selected value after dissipation of the dicrotic notch (T 1/2) was determined in newborn infants with and without pulmonary hypertension. The mean T 1/2 was 671 +/- 167 msec in seven infants with clinical evidence of pulmonary hypertension and documented right to left ductus arteriosus shunting; 849 +/- 243 msec in nine infants with clinical evidence of pulmonary hypertension but no documented right to left ductus arteriosus shunting; and 457 +/- 66 msec in eight infants with hyaline membrane disease and no clinical evidence of pulmonary hypertension or a patent ductus arteriosus. The mean T 1/2 values in the former two groups were significantly different from that in the group with no pulmonary hypertension (P less than 0.01). An evaluation of factors affecting T 1/2 leads to the conclusion that the patients with pulmonary hypertension had increased systemic vascular resistance as well. This finding has important diagnostic, etiologic and therapeutic implications.
Impact of Pulmonary Artery Pressure on Exercise Function in Severe COPD
Sims, Michael W.; Margolis, David J.; Localio, A. Russell; Panettieri, Reynold A.; Kawut, Steven M.; Christie, Jason D.
2009-01-01
Background: Although pulmonary hypertension commonly complicates COPD, the functional consequences of increased pulmonary artery pressures in patients with this condition remain poorly defined. Methods: We conducted a cross-sectional analysis of a cohort of 362 patients with severe COPD who were evaluated for lung transplantation. Patients with pulmonary hemodynamics measured by cardiac catheterization and available 6-min walk test results were included. The association of mean pulmonary artery pressure (mPAP) with pulmonary function, echocardiographic variables, and 6-min walk distance was assessed. Results: The prevalence of pulmonary hypertension (mPAP, > 25 mm Hg; pulmonary artery occlusion pressure [PAOP], < 16 mm Hg) was 23% (95% confidence interval, 19 to 27%). In bivariate analysis, higher mPAP was associated with lower FVC and FEV1, higher Pco2 and lower Po2 in arterial blood, and more right heart dysfunction. Multivariate analysis demonstrated that higher mPAP was associated with shorter distance walked in 6 min, even after adjustment for age, gender, race, height, weight, FEV1, and PAOP (−11 m for every 5 mm Hg rise in mPAP; 95% confidence interval, −21 to −0.7; p = 0.04). Conclusions: Higher pulmonary artery pressures are associated with reduced exercise function in patients with severe COPD, even after controlling for demographics, anthropomorphics, severity of airflow obstruction, and PAOP. Whether treatments aimed at lowering pulmonary artery pressures may improve clinical outcomes in COPD, however, remains unknown. PMID:19318664
Swift, Andrew J.; Wild, Jim M.; Nagle, Scott K.; Roldán-Alzate, Alejandro; François, Christopher J.; Fain, Sean; Johnson, Kevin; Capener, Dave; van Beek, Edwin J. R.; Kiely, David G.; Wang, Kang; Schiebler, Mark L.
2014-01-01
Pulmonary hypertension (PH) is a condition of varied aetiology, commonly associated with a poor clinical outcome. Patients are categorised on the basis of pathophysiological, clinical, radiological and therapeutic similarities. Pulmonary arterial hypertension (PAH) is often diagnosed late in its disease course with outcome dependent on aetiology, disease severity and response to treatment. Recent advances in quantitative MR imaging allow for a better initial characterization and measurement of the morphologic and flow related changes that accompany the response of the heart-lung axis to prolonged elevation of pulmonary arterial pressure and resistance and provide a reproducible, comprehensive and non-invasive means of assessing the course of the disease and response to treatment. Typical features of pulmonary arterial hypertension (PAH) occur primarily as a result of increased pulmonary vascular resistance and resultant increased RV afterload. Several MRI derived diagnostic markers have emerged, such as ventricular mass index (VMI), interventricular septal configuration and average pulmonary artery velocity having reported diagnostic accuracy similar to Doppler echocardiography. Furthermore, prognostic markers have been identified with independent predictive value for identification of treatment failure. Such markers include: large right ventricular end-diastolic volume index (RVEDVI), low left ventricular end diastolic volume index (LVEDVI), low right ventricular ejection fraction (RVEF) and relative area change of the pulmonary trunk. MRI is ideally suited to longitudinal follow-up of patients with PAH due to its non-invasive nature, high reproducibility and has the advantage over other biomarkers in PAH due to its sensitivity to change in morphological, functional and flow related parameters. Further study the role of MR imaging as a biomarker in the clinical environment is warranted. PMID:24552882
Parvathy, Usha T; Rajan, Rajesh; Faybushevich, Alexander Georgevich
2014-06-01
It is well known that mitral stenosis (MS) is complicated by pulmonary hypertension (PH) of varying degrees. The hemodynamic derangement is associated with structural changes in the pulmonary vessels and parenchyma and also functional derangements. This article analyzes the pulmonary function derangements in 25 patients with isolated/predominant mitral stenosis of varying severity. THE AIM OF THE STUDY WAS TO CORRELATE THE PULMONARY FUNCTION TEST (PFT) DERANGEMENTS (DONE BY SIMPLE METHODS) WITH: a) patient demographics and clinical profile, b) severity of the mitral stenosis, and c) severity of pulmonary artery hypertension (PAH) and d) to evaluate its significance in preoperative assessment. This cross-sectional study was conducted in 25 patients with mitral stenosis who were selected for mitral valve (MV) surgery. The patients were evaluated for clinical class, echocardiographic severity of mitral stenosis and pulmonary hypertension, and with simple methods of assessment of pulmonary function with spirometry and blood gas analysis. The diagnosis and classification were made on standardized criteria. The associations and correlations of parameters, and the difference in groups of severity were analyzed statistically with Statistical Package for Social Sciences (SPSS), using nonparametric measures. THE SPIROMETRIC PARAMETERS SHOWED SIGNIFICANT CORRELATION WITH INCREASING NEW YORK HEART ASSOCIATION (NYHA) FUNCTIONAL CLASS (FC): forced vital capacity (FVC, r = -0.4*, p = 0.04), forced expiratory volume in one second (FEV1, r = -0.5*, p = 0.01), FEV1/FVC (r = -0.44*, p = 0.02), and with pulmonary venous congestion (PVC): FVC (r = -0.41*, p = 0.04) and FEV1 (r = -0.41*, p = 0.04). Cardiothoracic ratio (CTR) correlated only with FEV1 (r = -0.461*, p = 0.02) and peripheral saturation of oxygen (SPO2, r = -0.401*, p = 0.04). There was no linear correlation to duration of symptoms, mitral valve orifice area, or pulmonary hypertension, except for MV gradient with PCO2 (r = 0.594**, p = 0.002). The decreased oxygenation status correlated significantly with FC, CTR, PVC, and with deranged spirometry (r = 0.495*, p = 0.02). PFT derangements are seen in all grades of severity of MS and correlate well with the functional class, though no significant linear correlation with grades of severity of stenosis or pulmonary hypertension. Even the early or mild derangements in pulmonary function such as small airway obstruction in the less severe cases of normal or mild PH can be detected by simple and inexpensive methods when the conventional parameters are normal. The supplementary data from baseline arterial blood gas analysis is informative and relevant. This reclassified pulmonary function status might be prognostically predictive.
Gorbunova, Elena E.; Dalrymple, Nadine A.; Gavrilovskaya, Irina N.
2013-01-01
Abstract Background Hantaviruses in the Americas cause a highly lethal acute pulmonary edema termed hantavirus pulmonary syndrome (HPS). Hantaviruses nonlytically infect microvascular and lymphatic endothelial cells and cause dramatic changes in barrier functions without disrupting the endothelium. Hantaviruses cause changes in the function of infected endothelial cells that normally regulate fluid barrier functions. The endothelium of arteries, veins, and lymphatic vessels are unique and central to the function of vast pulmonary capillary beds that regulate pulmonary fluid accumulation. Results We have found that HPS-causing hantaviruses alter vascular barrier functions of microvascular and lymphatic endothelial cells by altering receptor and signaling pathway responses that serve to permit fluid tissue influx and clear tissue edema. Infection of the endothelium provides several mechanisms for hantaviruses to cause acute pulmonary edema, as well as potential therapeutic targets for reducing the severity of HPS disease. Conclusions Here we discuss interactions of HPS-causing hantaviruses with the endothelium, roles for unique lymphatic endothelial responses in HPS, and therapeutic targeting of the endothelium as a means of reducing the severity of HPS disease. PMID:24024573
Mackow, Erich R; Gorbunova, Elena E; Dalrymple, Nadine A; Gavrilovskaya, Irina N
2013-09-01
Hantaviruses in the Americas cause a highly lethal acute pulmonary edema termed hantavirus pulmonary syndrome (HPS). Hantaviruses nonlytically infect microvascular and lymphatic endothelial cells and cause dramatic changes in barrier functions without disrupting the endothelium. Hantaviruses cause changes in the function of infected endothelial cells that normally regulate fluid barrier functions. The endothelium of arteries, veins, and lymphatic vessels are unique and central to the function of vast pulmonary capillary beds that regulate pulmonary fluid accumulation. We have found that HPS-causing hantaviruses alter vascular barrier functions of microvascular and lymphatic endothelial cells by altering receptor and signaling pathway responses that serve to permit fluid tissue influx and clear tissue edema. Infection of the endothelium provides several mechanisms for hantaviruses to cause acute pulmonary edema, as well as potential therapeutic targets for reducing the severity of HPS disease. Here we discuss interactions of HPS-causing hantaviruses with the endothelium, roles for unique lymphatic endothelial responses in HPS, and therapeutic targeting of the endothelium as a means of reducing the severity of HPS disease.
Impaired pulmonary function after treatment for tuberculosis: the end of the disease?
Chushkin, Mikhail Ivanovich; Ots, Oleg Nikolayevich
2017-01-01
To evaluate the prevalence of pulmonary function abnormalities and to investigate the factors affecting lung function in patients treated for pulmonary tuberculosis. A total of 214 consecutive patients (132 men and 82 women; 20-82 years of age), treated for pulmonary tuberculosis and followed at a local dispensary, underwent spirometry and plethysmography at least one year after treatment. Pulmonary impairment was present in 102 (47.7%) of the 214 patients evaluated. The most common functional alteration was obstructive lung disease (seen in 34.6%). Of the 214 patients, 60 (28.0%) showed reduced pulmonary function (FEV1 below the lower limit of normal). Risk factors for reduced pulmonary function were having had culture-positive pulmonary tuberculosis in the past, being over 50 years of age, having recurrent tuberculosis, and having a lower level of education. Nearly half of all tuberculosis patients evolve to impaired pulmonary function. That underscores the need for pulmonary function testing after the end of treatment. Avaliar a prevalência de alterações da função pulmonar e investigar os fatores que afetam a função pulmonar em pacientes tratados para tuberculose pulmonar. Um total de 214 pacientes consecutivos (132 homens e 82 mulheres; 20-82 anos de idade), tratados para tuberculose pulmonar e acompanhados em um dispensário local, foi submetido a espirometria e pletismografia pelo menos um ano após o tratamento. O comprometimento pulmonar estava presente em 102 (47,7%) dos 214 pacientes avaliados. A alteração funcional mais comum foi o distúrbio ventilatório obstrutivo (observado em 34,6%). Dos 214 pacientes, 60 (28,0%) apresentaram função pulmonar reduzida (VEF1 abaixo do limite inferior de normalidade). Os fatores de risco para função pulmonar reduzida foram tuberculose pulmonar com cultura positiva no passado, idade acima de 50 anos, recidiva de tuberculose e menor nível de escolaridade. Quase metade de todos os pacientes com tuberculose evolui com comprometimento da função pulmonar. Isso reforça a necessidade de testes de função pulmonar após o término do tratamento.
[Clinical, hemodynamic and angiographic results of total cavo-pulmonary connection].
Jimenez, A C; Neville, P; Chamboux, C; Crenn, R; Vaillant, M C; Marchand, M; Chantepie, A
1998-05-01
The aim of the study was to assess the short and medium term results of total cavo-pulmonary connection based on analysis of the functional status, the cavo-pulmonary circulation and the surgical techniques, and the hepatic consequences. Fifteen patients with congenital defects beyond repair were treated by total cavo-pulmonary connection at Tours between March 1st 1992 and July 30th 1996. There were 12 children (mean age: 6.3 years) and 3 adults aged 25 to 28. Results were assessed by clinical examination, hepatic function tests and cardiovascular investigations including right heart catheterisation with angiography in 14 patients. There were no fatalities. Seven patients were in functional Class I and 8 in Class II at medium term (average follow-up of 33 months). Hepatic function was mildly abnormal in all patients with an increase in serum bilirubin and gamma GT, and a decrease in the coagulation factors. The mean pressures in the atrial channel were 12 mmHg (9-16 mmHg), in the superior vena 13.2 mmHg (10-18 mmHg), in the right pulmonary artery 9.5 mmHg (7-15 mmHg) and 11.6 mmHg (8-16 mmHg) in the left pulmonary artery. Significant residual stenosis of a pulmonary branch was observed in 2 cases. The cavo-pulmonary anastomoses were out of line, one from the other, in all cases. The atrial channel was tubular in 9 cases and dilated with slight stagnation of the contrast medium in its inferior region in 5 cases. Total cavo-pulmonary connection transformed the clinical status of these patients but was associated with minor abnormalities of liver function. The quality of the cavo-pulmonary circulation and the surgical anastomoses was estimated to be satisfactory in the majority of cases.
Pulmonary Morbidity in Infancy after Exposure to Chorioamnionitis in Late Preterm Infants.
McDowell, Karen M; Jobe, Alan H; Fenchel, Matthew; Hardie, William D; Gisslen, Tate; Young, Lisa R; Chougnet, Claire A; Davis, Stephanie D; Kallapur, Suhas G
2016-06-01
Chorioamnionitis is an important cause of preterm birth, but its impact on postnatal outcomes is understudied. To evaluate whether fetal exposure to inflammation is associated with adverse pulmonary outcomes at 6 to 12 months' chronological age in infants born moderate to late preterm. Infants born between 32 and 36 weeks' gestational age were prospectively recruited (N = 184). Chorioamnionitis was diagnosed by placenta and umbilical cord histology. Select cytokines were measured in samples of cord blood. Validated pulmonary questionnaires were administered (n = 184), and infant pulmonary function testing was performed (n = 69) between 6 and 12 months' chronological age by the raised volume rapid thoracoabdominal compression technique. A total of 25% of participants had chorioamnionitis. Although infant pulmonary function testing variables were lower in infants born preterm compared with historical normative data for term infants, there were no differences between infants with chorioamnionitis (n = 20) and those without (n = 49). Boys and black infants had lower infant pulmonary function testing measurements than girls and white infants, respectively. Chorioamnionitis exposure was associated independently with wheeze (odds ratio [OR], 2.08) and respiratory-related physician visits (OR, 3.18) in the first year of life. Infants exposed to severe chorioamnionitis had increased levels of cord blood IL-6 and greater pulmonary morbidity at age 6 to 12 months than those exposed to mild chorioamnionitis. Elevated IL-6 was associated with significantly more respiratory problems (OR, 3.23). In infants born moderate or late preterm, elevated cord blood IL-6 and exposure to histologically identified chorioamnionitis was associated with respiratory morbidity during infancy without significant changes in infant pulmonary function testing measurements. Black compared with white and boy compared with girl infants had lower infant pulmonary function testing measurements and worse pulmonary outcomes.
Zuo, Yi Y.; Keating, Eleonora; Zhao, Lin; Tadayyon, Seyed M.; Veldhuizen, Ruud A. W.; Petersen, Nils O.; Possmayer, Fred
2008-01-01
Monolayers of a functional pulmonary surfactant (PS) can reach very low surface tensions well below their equilibrium value. The mechanism by which PS monolayers reach such low surface tensions and maintain film stability remains unknown. As shown previously by fluorescence microscopy, phospholipid phase transition and separation seem to be important for the normal biophysical properties of PS. This work studied phospholipid phase transitions and separations in monolayers of bovine lipid extract surfactant using atomic force microscopy. Atomic force microscopy showed phospholipid phase separation on film compression and a monolayer-to-multilayer transition at surface pressure 40–50 mN/m. The tilted-condensed phase consisted of domains not only on the micrometer scale, as detected previously by fluorescence microscopy, but also on the nanometer scale, which is below the resolution limits of conventional optical methods. The nanodomains were embedded uniformly within the liquid-expanded phase. On compression, the microdomains broke up into nanodomains, thereby appearing to contribute to tilted-condensed and liquid-expanded phase remixing. Addition of surfactant protein A altered primarily the nanodomains and promoted the formation of multilayers. We conclude that the nanodomains play a predominant role in affecting the biophysical properties of PS monolayers and the monolayer-to-multilayer transition. PMID:18212010
Study of spirometry in children from Mexico City
DOE Office of Scientific and Technical Information (OSTI.GOV)
Namihira, D.; Strope, G.L.; Helms, R.W.
1986-11-01
A study was conducted in two elementary schools in Mexico City to determine values for pulmonary function tests in school-aged residents of Mexico City. The schools were located in Xalostoc, a highly industrialized area of Mexico City, and San Lorenzo, a suburban area of the city. Although data regarding atmospheric pollution were not available, there is an acknowledged higher level of macroenvironmental air pollution in Xalostoc. Pulmonary function tests were performed on 468 children in San Lorenzo and 405 children in Xalostoc. No differences between residents of the two communities for acute or chronic respiratory conditions were detected by questionnaire.more » The pulmonary function data demonstrate that boys have larger forced vital capacities (FVC) and forced expiratory flows over the middle half of the FVC (FEF25-75) than girls. Slopes of regression lines for FVC but not for FEF25-75 are greater in boys and girls from Xalostoc than in boys and girls from San Lorenzo. This suggests that young children from Xalostoc may experience ill effects of air pollution but develop catch-up growth later. There were no important community or gender effects on slopes of regression lines for height and weight on age. In general, the regression lines for FVC and FEF25-75 were below regression lines reported for children of Mexican ancestry living at sea level.« less
Levack, William Mm; Jones, Bernadette; Grainger, Rebecca; Boland, Pauline; Brown, Melanie; Ingham, Tristram R
2016-01-01
Pulmonary rehabilitation is known to improve function and quality of life for people with chronic obstructive pulmonary disease (COPD). However, little research has been conducted on the influence of culture on experiences of pulmonary rehabilitation. This study examined factors influencing uptake of pulmonary rehabilitation by Māori with COPD in New Zealand. Grounded theory nested within kaupapa Māori methodology. Transcripts were analyzed from interviews and focus groups with 15 Māori and ten New Zealand non-Māori invited to attend pulmonary rehabilitation for COPD. Māori participants had either attended a mainstream hospital-based program, a community-based program designed "by Māori, for Māori", or had experienced both. Several factors influencing uptake of pulmonary rehabilitation were common to all participants regardless of ethnicity: 1) participants' past experiences (eg, of exercise; of health care systems), 2) attitudes and expectations, 3) access issues (eg, time, transport, and conflicting responsibilities), and 4) initial program experiences. These factors were moderated by the involvement of family and peers, interactions with health professionals, the way information on programs was presented, and by new illness events. For Māori, however, several additional factors were also identified relating to cultural experiences of pulmonary rehabilitation. In particular, Māori participants placed high value on whakawhanaungatanga: the making of culturally meaningful connections with others. Culturally appropriate communication and relationship building was deemed so important by some Māori participants that when it was absent, they felt strongly discouraged to attend pulmonary rehabilitation. Only the more holistic services offered a program in which they felt culturally safe and to which they were willing to return for ongoing rehabilitation. Lack of attention to cultural factors in the delivery of pulmonary rehabilitation may be a barrier to its uptake by indigenous, minority ethnic groups, such as New Zealand Māori. Indigenous-led or culturally responsive health care interventions for COPD may provide a solution to this issue.
García-Guasch, L; Caro-Vadillo, A; Manubens-Grau, J; Carretón, E; Morchón, R; Simón, F; Kramer, L H; Montoya-Alonso, J A
2013-09-01
Heartworm associated respiratory disease is a pulmonary syndrome in cats that results from the vascular and parenchymal inflammatory response associated with the arrival and death of Dirofilaria immitis worms into the distal pulmonary arteries. This parasite harbors intracellular Wolbachia, an endosymbiont bacteria. The association between the parasite and the bacteria is obligatory. Some studies suggest the involvement of Wolbachia in the development of the inflammatory reaction and in the polarization of the host immune response against the parasite. Barometric whole-body plethysmography is a non-invasive pulmonary function test that allows a dynamic study of breathing patterns and is useful to study airway disease and the response to different treatments. The aim of this prospective non-blinded study was to compare the influence of Wolbachia upon the respiratory function variables in a population of cats seropositive to D. immitis by use of Barometric whole-body plethysmography. Fourteen seropositive cats to Wolbachia and eight seronegative cats were put into the plethysmograph chamber and different respiratory variables were measured. The results were analyzed and compared between the two groups of animals. Significant differences were found for bronchoconstriction index variables PAU (pause) (P-value<0.05) and Penh (enhanced pause) (P-value<0.05). The results obtained in our study suggest that Wolbachia seems to produce a greater acute inflammatory response at bronchial, vascular and parenchymal level worsening the state of broncho-reactivity associated with the presence of seropositivity to D. immitis in cats. Copyright © 2013 Elsevier B.V. All rights reserved.
Clinicians' perceptions of the value of ventilation-perfusion scans.
Siegel, Alan; Holtzman, Stephen R; Bettmann, Michael A; Black, William C
2004-07-01
The goal of this investigation was to understand clinicians' perceptions of the probability of pulmonary embolism as a function of V/Q scan results of normal, low, intermediate, and high probability. A questionnaire was developed and distributed to 429 clinicians at a single academic medical center. The response rate was 44% (188 of 429). The questions included level of training, specialty, probability of PE given 1 of the 4 V/Q scan results, and estimations of the charges for V/Q scanning and pulmonary angiography, and estimations of the risks of pulmonary angiography. The medians and ranges for the probability of pulmonary embolism given a normal, low, intermediate, and high probability V/Q scan result were 2.5% (0-30), 12.5% (0.5-52.5), 41.25% (5-75), and 85% (5-100), respectively. Eleven percent (21 of 188) of the respondents listed the probability of PE in patients with a low probability V/Q scan as being 5% or less, and 33% (62 of 188) listed the probability of PE given an intermediate probability scan as 50% or greater. The majority correctly identified the rate of serious complications of pulmonary arteriography, but many respondents underestimated the charge for V/Q scans and pulmonary arteriography. A substantial minority of clinicians do not understand the probability of pulmonary embolism in patients with low and intermediate probability ventilation-perfusion scans. More quantitative reporting of results is recommended. This could be particularly important because VQ scans are used less frequently but are still needed in certain clinical situations.
Pulmonary functions in plastic factory workers: a preliminary study.
Khaliq, Farah; Singh, Pawan; Chandra, Prakash; Gupta, Keshav; Vaney, Neelam
2011-01-01
Exposure to long term air pollution in the work environment may result in decreased lung functions and various other health problems. A significant occupational hazard to lung functions is experienced by plastic factory workers. The present study is planned to assess the pulmonary functions of workers in the plastic factory where recycling of pastic material was done. These workers were constantly exposed to fumes of various chemicals throughout the day. Thirty one workers of plastic factory were assessed for their pulmonary functions. Parameters were compared with 31 age and sex matched controls not exposed to the same environment. The pulmonary function tests were done using Sibelmed Datospir 120 B portable spirometer. A significant decrease in most of the flow rates (MEF 25%, MEF 50%, MEF 75% and FEF 25-75%) and most of the lung volumes and capacities (FVC, FEV1, VC, TV, ERV, MVV) were observed in the workers. Smoking and duration of exposure were not affecting the lung functions as the non smokers also showed a similar decrement in pulmonary functions. Similarly the workers working for less than 5 years also had decrement in pulmonary functions indicating that their lungs are being affected even if they have worked for one year. Exposure to the organic dust in the work environment should be controlled by adequate engineering measures, complemented by effective personal respiratory protection.
Indoor mold exposure associated with neurobehavioral and pulmonary impairment: a preliminary report.
Kilburn, Kaye H
2003-07-01
Recently, patients who have been exposed indoors to mixed molds, spores, and mycotoxins have reported asthma, airway irritation and bleeding, dizziness, and impaired memory and concentration, all of which suggest the presence of pulmonary and neurobehavioral problems. The author evaluated whether such patients had measurable pulmonary and neurobehavioral impairments by comparing consecutive cases in a series vs. a referent group. Sixty-five consecutive outpatients exposed to mold in their respective homes in Arizona, California, and Texas were compared with 202 community subjects who had no known mold or chemical exposures. Balance, choice reaction time, color discrimination, blink reflex, visual fields, grip, hearing, problem-solving, verbal recall, perceptual motor speed, and memory were measured. Medical histories, mood states, and symptom frequencies were recorded with checklists, and spirometry was used to measure various pulmonary volumes and flows. Neurobehavioral comparisons were made after individual measurements were adjusted for age, educational attainment, and sex. Significant differences between groups were assessed by analysis of variance; a p value of less than 0.05 was used for all statistical tests. The mold-exposed group exhibited decreased function for balance, reaction time, blink-reflex latency, color discrimination, visual fields, and grip, compared with referents. The exposed group's scores were reduced for the following tests: digit-symbol substitution, peg placement, trail making, verbal recall, and picture completion. Twenty-one of 26 functions tested were abnormal. Airway obstructions were found, and vital capacities were reduced. Mood state scores and symptom frequencies were elevated. The author concluded that indoor mold exposures were associated with neurobehavioral and pulmonary impairments that likely resulted from the presence of mycotoxins, such as trichothecenes.
Effect of Exercise on Pulmonary Function Tests in Obese Malaysian Patients.
Christopher, L K S; Kosai, N R; Reynu, R; Levin, K B; Taher, M M; Sutton, P A; Sukor, N; Das, S
2015-01-01
Obesity has taken the 21st century by storm, posing negative effects on of the various facades of health, healthcare and global economy. With regards to pulmonary performance, numerous studies have proven the detrimental effects of obesity while reinstating the positive effects of weight loss on overall pulmonary function. However, effects of exercise on pulmonary function and correlation between changes in pulmonary function test with weight loss have yet to be described. We performed a prospective interventional study to determine the effects of regular exercise on Pulmonary Function Tests (PFT) and ascertain the relationship between weight loss and change in PFT in obese patients. Twenty-five obese patients were enrolled, giving an 80% power of study. Baseline weight and PFT consisting of FEV1, FVC, TLC, mean ERV and VC were recorded prior to commencement of the 8 week long Standard Exercise Regimen (SER). PFT and weight were recorded again at the end of 8 weeks. All parameters of the PFT studied improved significantly with exercise. The participants lost an average of 1kg of body weight post-exercise (p<0.0005). The correlations between mean changes in weight and PFT were negligible. A period of supervised regular exercise improves the pulmonary function of obese patients and this improvement is independent of the amount of weight loss. Hence, SER should be recommended to all obese patients, especially when bariatric surgery is desired.
Báez-Saldaña, Renata; López-Arteaga, Yesenia; Bizarrón-Muro, Alma; Ferreira-Guerrero, Elizabeth; Ferreyra-Reyes, Leticia; Delgado-Sánchez, Guadalupe; Cruz-Hervert, Luis Pablo; Mongua-Rodríguez, Norma; García-García, Lourdes
2013-01-01
Despite chemotherapy, patients with cured pulmonary tuberculosis may result in lung functional impairment. To evaluate a novel scoring system based on the degree of radiographic abnormalities and related spirometric values in patients with cured pulmonary tuberculosis. One hundred and twenty seven patients with cured pulmonary tuberculosis were prospectively enrolled in a referral hospital specializing in respiratory diseases. Spirometry was performed and the extent of radiographic abnormalities was evaluated twice by each of two readers to generate a novel quantitative score. Scoring reproducibility was analyzed by the intra-class correlation coefficient (ICC) and the Bland-Altman method. Multiple linear regression models were performed to assess the association of the extent of radiographic abnormalities with spirometric values. The intra-observer agreement for scoring of radiographic abnormalities (SRA) showed an ICC of 0.81 (CI:95%, 0.67-0.95) and 0.78 (CI:95%, 0.65-0.92), for reader 1 and 2, respectively. Inter-observer reproducibility for the first measurement was 0.83 (CI:95%, 0.71-0.95), and for the second measurement was 0.74 (CI:95%, 0.58-0.90). The Bland-Altman analysis of the intra-observer agreement showed a mean bias of 0.87% and -0.55% and an inter-observer agreement of -0.35% and -1.78%, indicating a minor average systematic variability. After adjustment for age, gender, height, smoking status, pack-years of smoking, and degree of dyspnea, the scoring degree of radiographic abnormalities was significantly and negatively associated with absolute and percent predicted values of FVC: -0.07 (CI:95%, -0.01 to -0.04); -2.48 (CI:95%, -3.45 to -1.50); and FEV1 -0.07 (CI:95%, -0.10 to -0.05); -2.92 (CI:95%, -3.87 to -1.97) respectively, in the patients studied. The extent of radiographic abnormalities, as evaluated through our novel scoring system, was inversely associated with spirometric values, and exhibited good reliability and reproducibility. As intra-observer and inter-observer agreement of the SRA varied from good to excellent, the use of SRA in this setting appears acceptable.
Báez-Saldaña, Renata; López-Arteaga, Yesenia; Bizarrón-Muro, Alma; Ferreira-Guerrero, Elizabeth; Ferreyra-Reyes, Leticia; Delgado-Sánchez, Guadalupe; Cruz-Hervert, Luis Pablo; Mongua-Rodríguez, Norma; García-García, Lourdes
2013-01-01
Background Despite chemotherapy, patients with cured pulmonary tuberculosis may result in lung functional impairment. Objective To evaluate a novel scoring system based on the degree of radiographic abnormalities and related spirometric values in patients with cured pulmonary tuberculosis. Methods One hundred and twenty seven patients with cured pulmonary tuberculosis were prospectively enrolled in a referral hospital specializing in respiratory diseases. Spirometry was performed and the extent of radiographic abnormalities was evaluated twice by each of two readers to generate a novel quantitative score. Scoring reproducibility was analyzed by the intra-class correlation coefficient (ICC) and the Bland-Altman method. Multiple linear regression models were performed to assess the association of the extent of radiographic abnormalities with spirometric values. Results The intra-observer agreement for scoring of radiographic abnormalities (SRA) showed an ICC of 0.81 (CI:95%, 0.67–0.95) and 0.78 (CI:95%, 0.65–0.92), for reader 1 and 2, respectively. Inter-observer reproducibility for the first measurement was 0.83 (CI:95%, 0.71–0.95), and for the second measurement was 0.74 (CI:95%, 0.58–0.90). The Bland-Altman analysis of the intra-observer agreement showed a mean bias of 0.87% and -0.55% and an inter-observer agreement of -0.35% and -1.78%, indicating a minor average systematic variability. After adjustment for age, gender, height, smoking status, pack-years of smoking, and degree of dyspnea, the scoring degree of radiographic abnormalities was significantly and negatively associated with absolute and percent predicted values of FVC: -0.07 (CI:95%, -0.01 to -0.04); -2.48 (CI:95%, -3.45 to -1.50); and FEV1 -0.07 (CI:95%, -0.10 to -0.05); -2.92 (CI:95%, -3.87 to -1.97) respectively, in the patients studied. Conclusion The extent of radiographic abnormalities, as evaluated through our novel scoring system, was inversely associated with spirometric values, and exhibited good reliability and reproducibility. As intra-observer and inter-observer agreement of the SRA varied from good to excellent, the use of SRA in this setting appears acceptable. PMID:24223865
Caro-Domínguez, Pablo; Compton, Gregory; Humpl, Tilman; Manson, David E
2016-09-01
The ratio of the transverse diameter of the main pulmonary artery (MPA) to ascending aorta as determined at multi-detector CT is a tool that can be used to assess the pulmonary arterial size in cases of pulmonary arterial hypertension in children. To establish a ratio of MPA to ascending aorta diameter using multi-detector CT imaging suggestive of pulmonary arterial hypertension in children. We hypothesize that a defined ratio of MPA to ascending aorta is identifiable on multi-detector CT and that higher ratios can be used to reliably diagnose the presence of pulmonary arterial hypertension in children. We calculated the multi-detector CT ratio of MPA to ascending aorta diameter in 44 children with documented pulmonary arterial hypertension by right heart catheterization and in 44 age- and gender-matched control children with no predisposing factors for pulmonary arterial hypertension. We compared this multi-detector-CT-determined ratio with the MPA pressure in the study group, as well as with the ratio of MPA to ascending aorta in the control group. A threshold ratio value was calculated to accurately identify children with pulmonary arterial hypertension. Children with documented primary pulmonary arterial hypertension have a significantly higher ratio of MPA to ascending aorta (1.46) than children without pulmonary arterial hypertension (1.11). A ratio of 1.3 carries a positive likelihood of 34 and a positive predictive value of 97% for the diagnosis of pulmonary arterial hypertension. The pulmonary arteries were larger in children with pulmonary arterial hypertension than in a control group of normal children. A CT-measured ratio of MPA to ascending aorta of 1.3 should raise the suspicion of pulmonary arterial hypertension in children.
Sleep and pulmonary outcomes for clinical trials of airway plexiform neurofibromas in NF1.
Plotkin, Scott R; Davis, Stephanie D; Robertson, Kent A; Akshintala, Srivandana; Allen, Julian; Fisher, Michael J; Blakeley, Jaishri O; Widemann, Brigitte C; Ferner, Rosalie E; Marcus, Carole L
2016-08-16
Plexiform neurofibromas (PNs) are complex, benign nerve sheath tumors that occur in approximately 25%-50% of individuals with neurofibromatosis type 1 (NF1). PNs that cause airway compromise or pulmonary dysfunction are uncommon but clinically important. Because improvement in sleep quality or airway function represents direct clinical benefit, measures of sleep and pulmonary function may be more meaningful than tumor size as endpoints in therapeutic clinical trials targeting airway PN. The Response Evaluation in Neurofibromatosis and Schwannomatosis functional outcomes group reviewed currently available endpoints for sleep and pulmonary outcomes and developed consensus recommendations for response evaluation in NF clinical trials. For patients with airway PNs, polysomnography, impulse oscillometry, and spirometry should be performed to identify abnormal function that will be targeted by the agent under clinical investigation. The functional group endorsed the use of the apnea hypopnea index (AHI) as the primary sleep endpoint, and pulmonary resistance at 10 Hz (R10) or forced expiratory volume in 1 or 0.75 seconds (FEV1 or FEV0.75) as primary pulmonary endpoints. The group defined minimum changes in AHI, R10, and FEV1 or FEV0.75 for response criteria. Secondary sleep outcomes include desaturation and hypercapnia during sleep and arousal index. Secondary pulmonary outcomes include pulmonary resistance and reactance measurements at 5, 10, and 20 Hz; forced vital capacity; peak expiratory flow; and forced expiratory flows. These recommended sleep and pulmonary evaluations are intended to provide researchers with a standardized set of clinically meaningful endpoints for response evaluation in trials of NF1-related airway PNs. © 2016 American Academy of Neurology.
Correlation between pulmonary function and brain volume in healthy elderly subjects.
Taki, Yasuyuki; Kinomura, Shigeo; Ebihara, Satoru; Thyreau, Benjamin; Sato, Kazunori; Goto, Ryoi; Kakizaki, Masako; Tsuji, Ichiro; Kawashima, Ryuta; Fukuda, Hiroshi
2013-06-01
Cigarette smoking decreases brain regional gray matter volume and is related to chronic obstructive lung disease (COPD). COPD leads to decreased pulmonary function, which is represented by forced expiratory volume in one second percentage (FEV1.0 %); however, it is unclear if decreased pulmonary function is directly related to brain gray matter volume decline. Because there is a link between COPD and cognitive decline, revealing a direct relationship between pulmonary function and brain structure is important to better understand how pulmonary function affects brain structure and cognitive function. Therefore, the purpose of this study was to analyze whether there were significant correlations between FEV1.0 % and brain regional gray and white matter volumes using brain magnetic resonance (MR) image data from 109 community-dwelling healthy elderly individuals. Brain MR images were processed with voxel-based morphometry using a custom template by applying diffeomorphic anatomical registration using the exponentiated lie algebra procedure. We found a significant positive correlation between the regional white matter volume of the cerebellum and FEV1.0 % after adjusting for age, sex, and intracranial volume. Our results suggest that elderly individuals who have a lower FEV1.0 % have decreased regional white matter volume in the cerebellum. Therefore, preventing decreased pulmonary function is important for cerebellar white matter volume in the healthy elderly population.
du Bois, Roland M; Weycker, Derek; Albera, Carlo; Bradford, Williamson Z; Costabel, Ulrich; Kartashov, Alex; Lancaster, Lisa; Noble, Paul W; Sahn, Steven A; Szwarcberg, Javier; Thomeer, Michiel; Valeyre, Dominique; King, Talmadge E
2011-05-01
The 6-minute-walk test (6MWT) is a practical and clinically meaningful measure of exercise tolerance with favorable performance characteristics in various cardiac and pulmonary diseases. Performance characteristics in patients with idiopathic pulmonary fibrosis (IPF) have not been systematically evaluated. To assess the reliability, validity, and responsiveness of the 6MWT and estimate the minimal clinically important difference (MCID) in patients with IPF. The study population included all subjects completing a 6MWT in a clinical trial evaluating interferon gamma-1b (n = 822). Six-minute walk distance (6MWD) and other parameters were measured at baseline and at 24-week intervals using a standardized protocol. Parametric and distribution-independent correlation coefficients were used to assess the strength of the relationships between 6MWD and measures of pulmonary function, dyspnea, and health-related quality of life. Both distribution-based and anchor-based methods were used to estimate the MCID. Comparison of two proximal measures of 6MWD (mean interval, 24 d) demonstrated good reliability (coefficient = 0.83; P < 0.001). 6MWD was weakly correlated with measures of physiologic function and health-related quality of life; however, values were consistently and significantly lower for patients with the poorest functional status, suggesting good construct validity. Importantly, change in 6MWD was highly predictive of mortality; a 24-week decline of greater than 50 m was associated with a fourfold increase in risk of death at 1 year (hazard ratio, 4.27; 95% confidence interval, 2.57- 7.10; P < 0.001). The estimated MCID was 24-45 m. The 6MWT is a reliable, valid, and responsive measure of disease status and a valid endpoint for clinical trials in IPF.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koenig, J.Q.; Covert, D.S.; Larson, T.V.
To evaluate the pulmonary effects of varying doses of sulfuric acid, adolescent subjects with asthma were exposed to 35 or 70 micrograms/m3 sulfuric acid for 45 or 90 min. Exposure was carried out during intermittent moderate exercise. The pulmonary functions measured before and after exposure were FEV1, FVC, and total respiratory resistance. The 45 min exposures were associated with larger decreases in FEV1 (-6% or -3%) than the 90 min exposures (-1% or +2%). Analysis of variance of the change in FEV1 among the exposures revealed that the 45 min exposure to 35 micrograms/m3 was significant (p = 0.03). Themore » p value for 45 min exposure to 70 micrograms/m3 was not significant (p = 0.08). Using analysis of variance, neither of the 90 min exposures was associated with a significant decrease in FEV1 compared to air exposure. Also, none of the changes in FVC or RT was significant. When baseline to post-exposure changes were compared for each of the five test atmospheres using paired t tests, both of the 45 min exposures were associated with statistical significance (p < 0.001 for 35 micrograms/m3 and p < 0.005 for 70 micrograms/m3). This baseline to post exposure change was not statistically significant for the 90 min exposures. The reason for the lesser effect on pulmonary function at increased exposure duration is not known; it may be due to changes in either varying deposition patterns or changes in buffering capacity of the cells lining the airways. With respect to individual sensitivities to H2SO4, the data showed a significant consistency across test atmospheres.« less
Lack of ventilatory threshold in patients with chronic obstructive pulmonary disease.
Midorikawa, J; Hida, W; Taguchi, O; Okabe, S; Kurosawa, H; Mizusawa, A; Ogawa, H; Ebihara, S; Kikuchi, Y; Shirato, K
1997-01-01
We investigated whether the ventilatory threshold (VET) could be detected in 25 patients with severe chronic obstructive pulmonary disease (COPD). Exercise on a treadmill was performed until symptom-limited maximum oxygen uptake (VO2SL) was obtained. VET was absent in 14 patients (56%, VET(-) group) and present in the others (44%, VET(+) group). Basal pulmonary functions and dyspnea index (VE,SL/MVV) were not different between the two groups. Endurance time and exercise tolerance (VO2SL/bw) were significantly less in VET(-) than in VET(+). In the former group, PaO2 and pH at maximal exercise decreased and PaCO2 increased significantly, but HCO3- did not change compared with the corresponding values before exercise. In the latter group, PaCO2 at maximal exercise increased significantly, and pH and HCO3- decreased significantly compared with the values before exercise, but PaO2 did not. The changes in PaO2 and PaCO2 were not different between the two groups, but changes in pH and HCO3- in VET(+) were greater than those in VET(-). These results suggest that the absence of VET in some COPD patients indicates a lower exercise capacity without producing metabolic acidosis. This may be caused by rapidly developing dyspnea.
Value of flexible bronchoscopy in the pre-operative work-up of solitary pulmonary nodules.
Schwarz, Carsten; Schönfeld, Nicolas; Bittner, Roland C; Mairinger, Thomas; Rüssmann, Holger; Bauer, Torsten T; Kaiser, Dirk; Loddenkemper, Robert
2013-01-01
The diagnostic value of flexible bronchoscopy in the pre-operative work-up of solitary pulmonary nodules (SPN) is still under debate among pneumologists, radiologists and thoracic surgeons. In a prospective observational manner, flexible bronchoscopy was routinely performed in 225 patients with SPN of unknown origin. Of the 225 patients, 80.5% had lung cancer, 7.6% had metastasis of an extrapulmonary primary tumour and 12% had benign aetiology. Unsuspected endobronchial involvement was found in 4.4% of all 225 patients (or in 5.5% of patients with lung cancer). In addition, flexible bronchoscopy clarified the underlying aetiology in 41% of the cases. The bronchoscopic biopsy results from the SPN were positive in 84 (46.5%) patients with lung cancer. Surgery was cancelled due to the results of flexible bronchoscopy in four cases (involvement of the right main bronchus (impaired pulmonary function did not allow pneumonectomy) n=1, small cell lung cancer n=1, bacterial pneumonia n=2), and the surgical strategy had to be modified to bilobectomy in one patient. Flexible bronchoscopy changed the planned surgical approach in five cases substantially. These results suggest that routine flexible bronchoscopy should be included in the regular pre-operative work-up of patients with SPN.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stanic, Sinisa, E-mail: sinisa.stanic@carle.com; Paulus, Rebecca; Timmerman, Robert D.
2014-04-01
Purpose: To investigate pulmonary function test (PFT) results and arterial blood gas changes (complete PFT) following stereotactic body radiation therapy (SBRT) and to see whether baseline PFT correlates with lung toxicity and overall survival in medically inoperable patients receiving SBRT for early stage, peripheral, non-small cell lung cancer (NSCLC). Methods and Materials: During the 2-year follow-up, PFT data were collected for patients with T1-T2N0M0 peripheral NSCLC who received effectively 18 Gy × 3 in a phase 2 North American multicenter study (Radiation Therapy Oncology Group [RTOG] protocol 0236). Pulmonary toxicity was graded by using the RTOG SBRT pulmonary toxicity scale. Paired Wilcoxon signedmore » rank test, logistic regression model, and Kaplan-Meier method were used for statistical analysis. Results: At 2 years, mean percentage predicted forced expiratory volume in the first second and diffusing capacity for carbon monoxide declines were 5.8% and 6.3%, respectively, with minimal changes in arterial blood gases and no significant decline in oxygen saturation. Baseline PFT was not predictive of any pulmonary toxicity following SBRT. Whole-lung V5 (the percentage of normal lung tissue receiving 5 Gy), V10, V20, and mean dose to the whole lung were almost identical between patients who developed pneumonitis and patients who were pneumonitis-free. Poor baseline PFT did not predict decreased overall survival. Patients with poor baseline PFT as the reason for medical inoperability had higher median and overall survival rates than patients with normal baseline PFT values but with cardiac morbidity. Conclusions: Poor baseline PFT did not appear to predict pulmonary toxicity or decreased overall survival after SBRT in this medically inoperable population. Poor baseline PFT alone should not be used to exclude patients with early stage lung cancer from treatment with SBRT.« less
Chichger, Havovi; Braza, Julie; Duong, Huetran; Harrington, Elizabeth O
2015-06-01
Enhanced protein tyrosine phosphorylation is associated with changes in vascular permeability through formation and dissolution of adherens junctions and regulation of stress fiber formation. Inhibition of the protein tyrosine phosphorylase SH2 domain-containing protein tyrosine phosphatase 2 (SHP2) increases tyrosine phosphorylation of vascular endothelial cadherin and β-catenin, resulting in disruption of the endothelial monolayer and edema formation in the pulmonary endothelium. Vascular permeability is a hallmark of acute lung injury (ALI); thus, enhanced SHP2 activity offers potential therapeutic value for the pulmonary vasculature in diseases such as ALI, but this has not been characterized. To assess whether SHP2 activity mediates protection against edema in the endothelium, we assessed the effect of molecular activation of SHP2 on lung endothelial barrier function in response to the edemagenic agents LPS and thrombin. Both LPS and thrombin reduced SHP2 activity, correlated with decreased focal adhesion kinase (FAK) phosphorylation (Y(397) and Y(925)) and diminished SHP2 protein-protein associations with FAK. Overexpression of constitutively active SHP2 (SHP2(D61A)) enhanced baseline endothelial monolayer resistance and completely blocked LPS- and thrombin-induced permeability in vitro and significantly blunted pulmonary edema formation induced by either endotoxin (LPS) or Pseudomonas aeruginosa exposure in vivo. Chemical inhibition of FAK decreased SHP2 protein-protein interactions with FAK concomitant with increased permeability; however, overexpression of SHP2(D61A) rescued the endothelium and maintained FAK activity and FAK-SHP2 protein interactions. Our data suggest that SHP2 activation offers the pulmonary endothelium protection against barrier permeability mediators downstream of the FAK signaling pathway. We postulate that further studies into the promotion of SHP2 activation in the pulmonary endothelium may offer a therapeutic approach for patients suffering from ALI.
Prognostication in Pulmonary Arterial Hypertension with Submaximal Exercise Testing.
Khatri, Vinod; Neal, Jennifer E; Burger, Charles D; Lee, Augustine S
2015-02-06
The submaximal exercise test (SET), which gives both a measure of exercise tolerance, as well as disease severity, should be a more robust functional and prognostic marker than the six-minute walk test (6MWT). This study aimed to determine the prognostic value of SET as predicted by the validated REVEAL (Registry to Evaluate Early and Long-Term Pulmonary Artery Hypertension Disease Management) registry risk score (RRRS). Sixty-five consecutive patients with idiopathic and associated pulmonary arterial hypertension (PAH) underwent right-heart catheterization, echocardiogram, 6MWT and a three-minute SET (Shape-HF™). Analyses explored the association between SET variables and prognosis predicted by the RRRS. Although multiple SET variables correlated with the RRRS on univariate analyses, only V E /V CO2 (r = 0.57, p < 0.0001) remained an independent predictor in multivariate analysis (β = 0.05, p = 0.0371). Additionally, the V E /V CO2 was the most discriminatory (area under receiver operating characteristic curve, 0.84) in identifying the highest-risk category (RRRS ≥ 10), with an optimal cut-off of 40.6, resulting in a high sensitivity (92%) and negative-predictive value (97%), but a lower specificity (67%). SETs, particularly the V E /V CO2 , appear to have prognostic value when compared to the RRRS. If validated in prospective trials, SET should prove superior to the 6MWT or the RRRS, with significant implications for both future clinical trials and clinical practice.
Wieshammer, Siegfried; Dreyhaupt, Jens; Müller, Dirk; Momm, Felix; Jakob, Andreas
2016-01-01
Recognizing heart disease is relevant to oncologists because cancer patients are at an increased risk of cardiac mortality due to shared risk factors and the adverse effects of cancer therapy. This study assessed the extent to which the measurement of N-terminal pro-B-type natriuretic peptide (NT-proBNP) aids in the diagnosis of heart disease in addition to a history of coronary artery disease and the presence of atrial fibrillation (composite test). The NT- proBNP cutoff value was 100 pg/ml. A series of 583 consecutive cancer patients (68.4 ± 11.0 years) who were referred because of cardiac or pulmonary symptoms prospectively underwent a diagnostic work-up. Heart disease was diagnosed if at least one of the following conditions was present: (a) history of coronary artery disease, (b) atrial fibrillation, (c) impaired left ventricular systolic function, (d) significant valvular disease, (e) pulmonary hypertension, or (f) left ventricular hypertrophy. Except for (a), all 6 conditions were associated with NT-proBNP >100 pg/ml. The sensitivity/specificity values of the composite test were 0.92/0.50 for any heart disease. Several extracardiac covariates were associated with NT-proBNP >100 pg/ml, which contributed to the low test specificity. The low specificity of NT-proBNP limits its value for the diagnosis of heart disease in cancer patients. © 2016 The Author(s) Published by S. Karger AG, Basel.
Value-based insurance design: aligning incentives and evidence in pulmonary medicine.
Fendrick, A Mark; Zank, Daniel C
2013-11-01
When consumers are required to pay the same out-of-pocket amount for pulmonary services for which clinical benefits depend on patient characteristics, clinical indication, and provider choice, there is an enormous potential for both underutilization and overutilization. Unlike most current one-size-fits-all health plan designs, value-based insurance design (V-BID) explicitly acknowledges clinical heterogeneity across the continuum of care. By adding clinical nuance to benefit design, V-BID seeks to align consumer and provider incentives with value, encouraging the use of high-value services and discouraging the use of low-value interventions. This article describes the concept of V-BID; creates a framework for its development in pulmonary medicine; and outlines how this concept aligns with research, care delivery, and payment reform initiatives.
Lei, Li; Jiajun, Sheng; Guangyi, Wang; Kaiyang, Lyu; Jing, Qin; Gongcheng, Liu; Bing, Ma; Shichu, Xiao; Shihui, Zhu
2015-06-01
To appraise the significance of extravascular lung water index (EVLWI), pulmonary vascular permeability index (PVPI), and intrathoracic blood volume index (ITBVI) in the differential diagnosis of the type of burn-induced pulmonary edema. The clinical data of 38 patients, with severe burn hospitalized in our burn ICU from December 2011 to September 2014 suffering from the complication of pulmonary edema within one week post burn and treated with mechanical ventilation accompanied by pulse contour cardiac output monitoring, were retrospectively analyzed. The patients were divided into lung injury group ( L, n = 17) and hydrostatic group (H, n = 21) according to the diagnosis of pulmonary edema. EVLWI, PVPI, ITBVI, oxygenation index, and lung injury score ( LIS) were compared between two groups, and the correlations among the former four indexes and the correlations between each of the former three indexes and types of pulmonary edema were analyzed. Data were processed with t test, chi-square test, Mann-Whitney U test, Pearson correlation test, and accuracy test [receiver operating characteristic (ROC) curve]. There was no statistically significant difference in EVLWI between group L and group H, respectively (12.9 ± 3.1) and (12.1 ± 2.1) mL/kg, U = 159.5, P > 0.05. The PVPI and LIS of patients in group L were respectively 2.6 ± 0.5 and (2.1 ± 0.6) points, and they were significantly higher than those in group H [1.4 ± 0.3 and (1.0 ± 0.6) points, with U values respectively 4.5 and 36.5, P values below 0.01]. The ITBVI and oxygenation index of patients in group L were respectively (911 197) mL/m2 and (136 ± 69) mmHg (1 mmHg = 0.133 kPa), which were significantly lower than those in group H [(1,305 ± 168) mL/m2 and (212 ± 60) mmHg, with U values respectively 21.5 and 70.5, P values below 0.01]. In group L, there was obviously positive correlation between EVLWI and PVPI, or EVLWI and ITBVI (with r values respectively 0.553 and 0.807, P < 0.05 or P < 0.01), and there was obviously negative correlation between oxygenation index and EVLWI, or oxygenation index and PVPI (with r values respectively -0.674 and -0.817, P values below 0.01). In group H, there was obviously positive correlation between EVLWI and ITBVI (r = 0.751, P < 0.01) but no obvious correlation between EVLWI and PVPI, oxygenation index and EVLWI, or oxygenation index and PVPI (with r values respectively -0.275, 0.197, and 0:062, P values above 0.05). The total area under ROC curve of PVPI value for differentiating the type of pulmonary edema was 0.987 [with 95% confidence interval (CI) 0.962-1.013, P < 0.01], and 1.9 was the cutoff value with sensitivity of 94.1% and specificity of 95.2% . The total area under ROC curve of ITBVI value for differentiating the type of pulmonary edema was 0.940 (with 95% CI 0.860-1.020, P < 0.01), and 1,077. 5 mL/m2 was the cutoff value with sensitivity of 95.2% and specificity of 88.2%. EVLWI, PVPI, and ITBVI have an important significance in the differential diagnosis of the type of burn-induced pulmonary edema, and they may be helpful in the early diagnosis and management of burn-induced pulmonary edema.
Regulation of pulmonary inflammation by mesenchymal cells.
Alkhouri, Hatem; Poppinga, Wilfred Jelco; Tania, Navessa Padma; Ammit, Alaina; Schuliga, Michael
2014-12-01
Pulmonary inflammation and tissue remodelling are common elements of chronic respiratory diseases such as asthma, chronic obstructive pulmonary disease (COPD), idiopathic pulmonary fibrosis (IPF), and pulmonary hypertension (PH). In disease, pulmonary mesenchymal cells not only contribute to tissue remodelling, but also have an important role in pulmonary inflammation. This review will describe the immunomodulatory functions of pulmonary mesenchymal cells, such as airway smooth muscle (ASM) cells and lung fibroblasts, in chronic respiratory disease. An important theme of the review is that pulmonary mesenchymal cells not only respond to inflammatory mediators, but also produce their own mediators, whether pro-inflammatory or pro-resolving, which influence the quantity and quality of the lung immune response. The notion that defective pro-inflammatory or pro-resolving signalling in these cells potentially contributes to disease progression is also discussed. Finally, the concept of specifically targeting pulmonary mesenchymal cell immunomodulatory function to improve therapeutic control of chronic respiratory disease is considered. Copyright © 2014 Elsevier Ltd. All rights reserved.
Chang, Sung Soo; Yokomise, Hiroyasu; Matsuura, Natsumi; Gotoh, Masashi; Tabata, Yasuhiko
2014-08-01
The prognosis of patients with emphysema is poor as there is no truly effective treatment. Our previous study showed that the alveolar space was smaller and the microvessel density was higher in a canine emphysema model after the intrapulmonary arterial administration of gelatin microspheres slowly releasing basic fibroblast growth factor (bFGF-GMS). In the present study, we evaluated the functional effect of injecting bFGF-GMS via the pulmonary artery in this canine pulmonary emphysema model. Using the porcine pancreatic elastase (PPE)-induced total emphysema model, we approximated the value of lung compliance with a Power Lab System, and performed blood gas analysis in a control group, a total emphysema group, and a bFGF group in which bFGF-GMS were injected toward the whole pulmonary artery via the femoral vein. Each group comprised five dogs. Lung compliance was higher in the total emphysema group than in the control group (p = 0.031), and the bFGF group showed no significant improvement of lung compliance vs. the total emphysema group (p = 0.112). PaO2 (partial pressure of oxygen in arterial blood) was improved by administering bFGF-GMS in the total emphysema model (p = 0.027). In the canine total emphysema model, blood gas parameters were improved by the whole pulmonary arterial administration of bFGF-GMS. This method has the potential to be an effective novel therapy for pulmonary emphysema.
Güvenç, Tolga Sinan; Erer, Hatice Betül; Kul, Seref; Perinçek, Gökhan; Ilhan, Sami; Sayar, Nurten; Yıldırım, Binnaz Zeynep; Doğan, Coşkun; Karabağ, Yavuz; Balcı, Bahattin; Eren, Mehmet
2013-01-01
Pulmonary vasculature is affected in patients with chronic pulmonary obstructive disease (COPD). As a result of increased pulmonary resistance, right ventricular morphology and function are altered in COPD patients. High altitude and related hypoxia causes pulmonary vasoconstriction, thereby affecting the right ventricle. We aimed to investigate the combined effects of COPD and altitude-related chronic hypoxia on right ventricular morphology and function. Forty COPD patients living at high altitude (1768 m) and 41 COPD patients living at sea level were enrolled in the study. All participants were diagnosed as COPD by a pulmonary diseases specialist depending on symptoms, radiologic findings and pulmonary function test results. Detailed two-dimensional echocardiography was performed by a cardiologist at both study locations. Oxygen saturation and mean pulmonary artery pressure were higher in the high altitude group. Right ventricular end diastolic diameter, end systolic diameter, height and end systolic area were significantly higher in the high altitude group compared to the sea level group. Parameters of systolic function, including tricuspid annular systolic excursion, systolic velocity of tricuspid annulus and right ventricular isovolumic acceleration were similar between groups, while fractional area change was significantly higher in the sea level groups compared to the high altitude group. Indices of diastolic function and myocardial performance index were similar between groups. An increase in mean pulmonary artery pressure and right ventricular dimensions are observed in COPD patients living at high altitude. Despite this increase, systolic and diastolic functions of the right ventricle, as well as global right ventricular performance are similar in COPD patients living at high altitude and sea level. Altitude-related adaptation to chronic hypoxia could explain these findings. Copyright © 2012 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
da Costa Junior, Augusto Alberto; Ota-Arakaki, Jaquelina Sonoe; Ramos, Roberta Pulcheri; Uellendahl, Marly; Mancuso, Frederico José Neves; Gil, Manuel Adan; Fischer, Cláudio Henrique; Moises, Valdir Ambrosio; de Camargo Carvalho, Antonio Carlos; Campos, Orlando
2017-01-01
Right ventricular (RV) dysfunction harbingers adverse prognosis in pulmonary arterial hypertension (PAH). Although conventional two-dimensional echocardiography (2DE) is limited for RV systolic function quantitation, RV strain can be a useful tool. The diagnostic and prognostic impact of 2DE speckle-tracking RV longitudinal strain was evaluated, including other 2DE systolic indexes, in a group of PAH patients without severe impairment of functional capacity, chronic pulmonary thromboembolism or left ventricular dysfunction. Sixty-six group I PAH patients, 67 % NYHA functional class I or II (none in IV) were studied by 2DE to obtain: RV fractional area change, tricuspid annular plane systolic excursion, RV myocardial performance index, tissue Doppler tricuspid annulus systolic velocity. Global, free wall (RVFreeWSt) and septal RV longitudinal systolic strain were obtained. RV ejection fraction by cardiac magnetic resonance (CMR-RVEF) was also assessed. All patients were followed up to 3.9 years (mean 3.3 years). Combined endpoints were hospitalization for worsening PAH or cardiovascular death. Among all the 2DE indexes of RV systolic function, RVFreeWSt exhibited the best correlation with CMR-RVEF (r = 0.83; p < 0.005). Combined endpoints occurred in 15 (22.7 %) patients (6 hospitalizations and 9 deaths). Multivariate analysis identified RVFreeWSt ≤-14 % as the only 2DE independent variable associated with combined endpoints [HR 4.66 (1.25-17.37); p < 0.05]. We conclude that RVFreeWSt may be a suitable non-geometric 2DE surrogate of CMR-RVEF in PAH patients, constituting a powerful independent predictor of long-term outcome in this cohort with relatively preserved functional capacity.
Hauck, Amanda; Guo, Ruixin; Ivy, D Dunbar; Younoszai, Adel
2017-04-01
Tricuspid annular plane systolic excursion (TAPSE) is a measure of right ventricular (RV) longitudinal function that correlates with functional status and mortality in adults with pulmonary hypertension (PH). The diagnostic and predictive value of TAPSE in children with PH has not been fully examined. We aimed to define TAPSE across aetiologies of paediatric PH and assess the correlation between TAPSE and measures of disease severity. TAPSE measurements were obtained in 84 children and young adults undergoing treatment for PH and 315 healthy children to establish z-scores at moderate altitude for comparison. The relationships between TAPSE and echocardiographic, biomarker, and functional measures of disease severity between aetiologies were assessed. TAPSE z-scores in PH patients with congenital heart disease (CHD) repaired with open cardiac surgery (n = 20, mean -2.73) were significantly decreased compared with normal children and patients with other aetiologies of PH (P < 0.001) but did not reflect poorer clinical status. TAPSE z-scores in children with idiopathic PH (n = 29, -0.41), unrepaired CHD (n = 11, -0.1), and PH related to systemic disease (n = 14, -0.39) were not different from normal. TAPSE correlated modestly with brain natriuretic peptide, echocardiographic function parameters, and functional class except in patients with repaired CHD. Children with PH maintain normal TAPSE values early except when associated with repaired CHD. Superior RV adaptation to high afterload in children compared with adults may account for this finding. Reduced TAPSE after repair of CHD does not correlate with functional status and may reflect post-operative changes rather than poor function primarily due to PH. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
International spinal cord injury pulmonary function basic data set.
Biering-Sørensen, F; Krassioukov, A; Alexander, M S; Donovan, W; Karlsson, A-K; Mueller, G; Perkash, I; Sheel, A William; Wecht, J; Schilero, G J
2012-06-01
To develop the International Spinal Cord Injury (SCI) Pulmonary Function Basic Data Set within the framework of the International SCI Data Sets in order to facilitate consistent collection and reporting of basic bronchopulmonary findings in the SCI population. International. The SCI Pulmonary Function Data Set was developed by an international working group. The initial data set document was revised on the basis of suggestions from members of the Executive Committee of the International SCI Standards and Data Sets, the International Spinal Cord Society (ISCoS) Executive and Scientific Committees, American Spinal Injury Association (ASIA) Board, other interested organizations and societies and individual reviewers. In addition, the data set was posted for 2 months on ISCoS and ASIA websites for comments. The final International SCI Pulmonary Function Data Set contains questions on the pulmonary conditions diagnosed before spinal cord lesion,if available, to be obtained only once; smoking history; pulmonary complications and conditions after the spinal cord lesion, which may be collected at any time. These data include information on pneumonia, asthma, chronic obstructive pulmonary disease and sleep apnea. Current utilization of ventilator assistance including mechanical ventilation, diaphragmatic pacing, phrenic nerve stimulation and Bi-level positive airway pressure can be reported, as well as results from pulmonary function testing includes: forced vital capacity, forced expiratory volume in one second and peak expiratory flow. The complete instructions for data collection and the data sheet itself are freely available on the website of ISCoS (http://www.iscos.org.uk).
Blood Biomarkers in Idiopathic Pulmonary Fibrosis.
Guiot, Julien; Moermans, Catherine; Henket, Monique; Corhay, Jean-Louis; Louis, Renaud
2017-06-01
Idiopathic pulmonary fibrosis (IPF) is a progressive and lethal lung disease of unknown origin whose incidence has been increasing over the latest decade partly as a consequence of population ageing. New anti-fibrotic therapy including pirfenidone and nintedanib have now proven efficacy in slowing down the disease. Nevertheless, diagnosis and follow-up of IPF remain challenging. This review examines the recent literature on potentially useful blood molecular and cellular biomarkers in IPF. Most of the proposed biomarkers belong to chemokines (IL-8, CCL18), proteases (MMP-1 and MMP-7), and growth factors (IGBPs) families. Circulating T cells and fibrocytes have also gained recent interest in that respect. Up to now, though several interesting candidates are profiling there has not been a single biomarker, which proved to be specific of the disease and predictive of the evolution (decline of pulmonary function test values, risk of acute exacerbation or mortality). Large scale multicentric studies are eagerly needed to confirm the utility of these biomarkers.
Swallowing impairment and pulmonary dysfunction in Parkinson's disease: the silent threats.
Monteiro, Larissa; Souza-Machado, Adelmir; Pinho, Patrícia; Sampaio, Marília; Nóbrega, Ana Caline; Melo, Ailton
2014-04-15
Swallowing disorders and respiratory impairment are frequent in Parkinson's disease (PD) patients, and aspiration pneumonia remains the leading cause of death among these subjects. The objective of this study was to investigate whether there is an association between pulmonary impairment and swallowing dysfunction in PD patients. A cross-sectional study with a comparison group was conducted with PD patients. Subjects were submitted to demographic questionnaires and underwent spirometric and videofluorographic assessments. Significance level was considered at 95% (p<0.05). Among 35 PD patients, 40% presented with swallowing complaints. However, 22% of the clinically asymptomatic patients presented airway food penetration when submitted to videofluoroscopy. In 20% of PD patients material entered the airways and there was contact with the vocal folds in 7%. However, there was an efficient cleaning with residue deglutition in almost all patients. No penetration/aspiration was detected among the controls. Respiratory parameters were below the normal predicted values in PD patients when compared to the healthy controls. These data suggest an association between pulmonary dysfunction and swallowing impairment in PD patients; even in patients without swallowing complaints, impaired pulmonary function can be detected. Copyright © 2014 Elsevier B.V. All rights reserved.
Zhang, Jinjin; Xu, Pan; Wang, Youlei; Wang, Meirong; Li, Hongbo; Lin, Shengcui; Mao, Cuiping; Wang, Bingsi; Song, Xiaodong; Lv, Changjun
2015-01-01
Promotion of myofibroblast apoptosis is a potential therapeutic strategy for pulmonary fibrosis. This study investigated the antifibrotic effect of astaxanthin on the promotion of myofibroblast apoptosis based on dynamin-related protein-1 (Drp1)-mediated mitochondrial fission in vivo and in vitro. Results showed that astaxanthin can inhibit lung parenchymal distortion and collagen deposition, as well as promote myofibroblast apoptosis. Astaxanthin demonstrated pro-apoptotic function in myofibroblasts by contributing to mitochondrial fission, thereby leading to apoptosis by increasing the Drp1 expression and enhancing Drp1 translocation into the mitochondria. Two specific siRNAs were used to demonstrate that Drp1 is necessary to promote astaxanthin-induced mitochondrial fission and apoptosis in myofibroblasts. Drp1-associated genes, such as Bcl-2-associated X protein, cytochrome c, tumour suppressor gene p53 and p53-up-regulated modulator of apoptosis, were highly up-regulated in the astaxanthin group compared with those in the sham group. This study revealed that astaxanthin can prevent pulmonary fibrosis by promoting myofibroblast apoptosis through a Drp1-dependent molecular pathway. Furthermore, astaxanthin provides a potential therapeutic value in pulmonary fibrosis treatment. PMID:26119034
Optical techniques in pulmonary medicine. SPIE photonics West.
Suter, Melissa J; Lam, Stephen; Brenner, Matthew
2012-04-01
There is ongoing interest in the emerging field of pulmonary photonic-based diagnostics. Potential clinical need areas that are being actively investigated at this time include airway and peripheral lung cancer diagnostics, pulmonary parenchymal and interstitial disorders, alveolar structure function, inhalation injury, ciliary function analysis, asthma and obstructive lung diseases.
Kogon, Brian; Mori, Makoto; Alsoufi, Bahaaldin; Kanter, Kirk; Oster, Matt
2015-06-01
Pulmonary valve disruption in patients with tetralogy of Fallot and congenital pulmonary stenosis often results in pulmonary insufficiency, right ventricular dilation, and tricuspid valve regurgitation. Management of functional tricuspid regurgitation at the time of subsequent pulmonary valve replacement remains controversial. Our aims were to (1) analyze tricuspid valve function after pulmonary valve replacement through midterm follow-up and (2) determine the benefits, if any, of concomitant tricuspid annuloplasty. Thirty-five patients with tetralogy of Fallot or congenital pulmonary stenosis were analyzed. All patients had been palliated in childhood by disrupting the pulmonary valve, and all patients had at least moderate tricuspid valve regurgitation at the time of subsequent pulmonary valve replacement. Preoperative and serial postoperative echocardiograms were analyzed. Pulmonary and tricuspid regurgitation, along with right ventricular dilation and dysfunction were scored as 0 (none), 1 (mild), 2 (moderate), and 3 (severe). Right ventricular volume and area were also calculated. Comparisons were made between patients who underwent pulmonary valve replacement alone and those who underwent concomitant tricuspid valve annuloplasty. At 1 month after pulmonary valve replacement, there were significant reductions in pulmonary valve regurgitation (mean 3 vs 0.39, p < 0.0001), tricuspid valve regurgitation (mean 2.33 vs 1.3, p < 0.0001), and in right ventricular dilation, volume, and area. There was no difference in the degree of tricuspid regurgitation 1 month postoperatively between patients who underwent concomitant tricuspid annuloplasty and those who underwent pulmonary valve replacement alone (mean 1.31 vs 1.29, p = 0.81). However, at latest follow-up (mean 7.0 ± 2.8 years), the degree of tricuspid regurgitation was significantly higher in the concomitant annuloplasty group (mean 1.87 vs 1.12, p = 0.005). In patients with at least moderate tricuspid valve regurgitation, significant improvement in tricuspid valve function and right ventricular size occurs in the first postoperative month after pulmonary valve replacement, irrespective of concomitant tricuspid valve annuloplasty. The tricuspid valve appears to function better over the midterm if annuloplasty is not performed. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Neghab, M; Zare Derisi, F; Hassanzadeh, J
2015-04-01
Controversy exists as to the potential of asphalt fumes to induce respiratory symptoms and lung functional impairments. To examine the respiratory effects, if any, of occupational inhalation exposure to asphalt fumes. In this cross-sectional study, 74 asphalt workers and 110 unexposed employees were investigated. The prevalence of respiratory symptoms among subjects was investigated by a standard questionnaire. Additionally, the parameters of pulmonary function were measured both, prior to exposure and at the end of work-shift. Furthermore, to assess the extent to which workers were exposed to asphalt fumes, total particulate and the benzene-soluble fraction were measured in different worksites. The mean levels of exposure to total particulate and benzene-soluble fraction in asphalt fumes were estimated to be 0.9 (SD 0.2) and 0.3 (SD 0.1) mg/m^3, respectively. Mean values of FEV1, both prior to the exposure (89.58% [SD 18.69%] predicted value) and at the end of shift (85.38% [SD 19.4%]), were significantly (p<0.05) smaller than those of the comparison subjects (93.88% [SD 13.93%]). Similarly, pre-shift (87.05 [SD 8.57]) and postexposure (89.95 [SD 6.85]) FEV1/FVC ratio were both significantly (p<0.01) lower than those of the unexposed employees (107.56 [SD 9.64]). Moreover, the prevalence of respiratory symptoms such as cough and wheezing in exposed employees were 41% and 42%, respectively. The corresponding values for comparison subjects were 10.0% and 3.6%, respectively (p<0.001). The pattern of changes in parameters of lung function in asphalt workers was consistent with that of chronic obstructive lung disease. Significant decrements in the parameters of pulmonary function as well as, a significant increase in the prevalence of respiratory symptoms in asphalt paving workers compared to their unexposed counterparts provided evidence in favor of a significant association between exposure to asphalt fumes and lung function impairments.
GPCRs in pulmonary arterial hypertension: tipping the balance.
Iyinikkel, Jean; Murray, Fiona
2018-02-21
Pulmonary arterial hypertension (PAH) is a progressive, fatal disease characterised by increased pulmonary vascular resistance and excessive proliferation of pulmonary artery smooth muscle cells (PASMC). GPCRs, which are attractive pharmacological targets, are important regulators of pulmonary vascular tone and PASMC phenotype. PAH is associated with the altered expression and function of a number of GPCRs in the pulmonary circulation, which leads to the vasoconstriction and proliferation of PASMC and thereby contributes to the imbalance of pulmonary vascular tone associated with PAH; drugs targeting GPCRs are currently used clinically to treat PAH and extensive preclinical work supports the utility of a number of additional GPCRs. Here we review how GPCR expression and function changes with PAH and discuss why GPCRs continue to be relevant drug targets for the disease. © 2018 The British Pharmacological Society.
Pulmonary function and respiratory symptoms of school children exposed to ambient air pollution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Yoon Shin; Ko, Ung Ring
1996-12-31
This study was undertaken to evaluate the health effect of air pollution on pulmonary function and respiratory symptoms of Korean school children between 7 and 10 years of age during November 1995-January 1996. A standard respiratory symptom questionnaire was administered and spirometry was performed to examine pulmonary function of 121 children in an urban polluted area, Seoul, and of 119 children in non-polluted area, Sokcho, respectively. There was significant difference in the level of pulmonary function [forced expiratory volume in second (FEV{sub 1.0}) and forced vital capacity (FVC)] between exposed groups to polluted area and non-polluted area. Parental smoking wasmore » significantly related to respiratory symptoms of cough, phlegm, and the level of pulmonary function. The observed changes in FEV{sub 1.0} and FVC seemed to relate to home cooking fuel, not to respiratory symptoms. The additional longitudinal work that carefully monitors ambient and indoor air pollution and health effects data should be conducted to confirm these results.« less
Pulmonary function outcomes for assessing cystic fibrosis care.
Wagener, Jeffrey S; Elkin, Eric P; Pasta, David J; Schechter, Michael S; Konstan, Michael W; Morgan, Wayne J
2015-05-01
Assessing cystic fibrosis (CF) patient quality of care requires the choice of an appropriate outcome measure. We looked systematically and in detail at pulmonary function outcomes that potentially reflect clinical practice patterns. Epidemiologic Study of Cystic Fibrosis data were used to evaluate six potential outcome variables (2002 best FVC, FEV(1), and FEF(25-75) and rate of decline for each from 2000 to 2002). We ranked CF care sites by outcome measure and then assessed any association with practice patterns and follow-up pulmonary function. Sites ranked in the top quartile had more frequent monitoring, treatment of exacerbations, and use of chronic therapies and oral corticosteroids. The follow-up rate of pulmonary function decline was not predicted by site ranking. Different pulmonary function outcomes associate slightly differently with practice patterns, although annual FEV(1) is at least as good as any other measure. Current site ranking only moderately predicts future ranking. Copyright © 2014 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Hyperpolarized Gas MRI: Technique and Applications
McAdams, Holman P.; Kaushik, S. Sivaram; Driehuys, Bastiaan
2015-01-01
Synopsis Functional imaging today offers a rich world of information that is more sensitive to changes in lung structure and function than traditionally obtained pulmonary function tests. Hyperpolarized helium (3He) and xenon (129Xe) MR imaging of the lungs provided new sensitive contrast mechanisms to probe changes in pulmonary ventilation, microstructure and gas exchange. With the recent scarcity in the supply of 3He the field of hyperpolarized gas imaging shifted to the use of cheaper and naturally available 129Xe. Xenon is well tolerated and recent technical advances have ensured that the 129Xe image quality is on par with that of 3He. The added advantage of 129Xe is its solubility in pulmonary tissue, which allows exploring specific lung function characteristics involved in gas exchange and alveolar oxygenation. With a plethora of contrast mechanisms, hyperpolarized gases and 129Xe in particular, stands to be an excellent probe of pulmonary structure and function, and provide sensitive and non-invasive biomarkers for a wide variety of pulmonary diseases. PMID:25952516
Evaluation of pulmonary function using single-breath-hold dual-energy computed tomography with xenon
Kyoyama, Hiroyuki; Hirata, Yusuke; Kikuchi, Satoshi; Sakai, Kosuke; Saito, Yuriko; Mikami, Shintaro; Moriyama, Gaku; Yanagita, Hisami; Watanabe, Wataru; Otani, Katharina; Honda, Norinari; Uematsu, Kazutsugu
2017-01-01
Abstract Xenon-enhanced dual-energy computed tomography (xenon-enhanced CT) can provide lung ventilation maps that may be useful for assessing structural and functional abnormalities of the lung. Xenon-enhanced CT has been performed using a multiple-breath-hold technique during xenon washout. We recently developed xenon-enhanced CT using a single-breath-hold technique to assess ventilation. We sought to evaluate whether xenon-enhanced CT using a single-breath-hold technique correlates with pulmonary function testing (PFT) results. Twenty-six patients, including 11 chronic obstructive pulmonary disease (COPD) patients, underwent xenon-enhanced CT and PFT. Three of the COPD patients underwent xenon-enhanced CT before and after bronchodilator treatment. Images from xenon-CT were obtained by dual-source CT during a breath-hold after a single vital-capacity inspiration of a xenon–oxygen gas mixture. Image postprocessing by 3-material decomposition generated conventional CT and xenon-enhanced images. Low-attenuation areas on xenon images matched low-attenuation areas on conventional CT in 21 cases but matched normal-attenuation areas in 5 cases. Volumes of Hounsfield unit (HU) histograms of xenon images correlated moderately and highly with vital capacity (VC) and total lung capacity (TLC), respectively (r = 0.68 and 0.85). Means and modes of histograms weakly correlated with VC (r = 0.39 and 0.38), moderately with forced expiratory volume in 1 second (FEV1) (r = 0.59 and 0.56), weakly with the ratio of FEV1 to FVC (r = 0.46 and 0.42), and moderately with the ratio of FEV1 to its predicted value (r = 0.64 and 0.60). Mode and volume of histograms increased in 2 COPD patients after the improvement of FEV1 with bronchodilators. Inhalation of xenon gas caused no adverse effects. Xenon-enhanced CT using a single-breath-hold technique depicted functional abnormalities not detectable on thin-slice CT. Mode, mean, and volume of HU histograms of xenon images reflected pulmonary function. Xenon images obtained with xenon-enhanced CT using a single-breath-hold technique can qualitatively depict pulmonary ventilation. A larger study comprising only COPD patients should be conducted, as xenon-enhanced CT is expected to be a promising technique for the management of COPD. PMID:28099359
Kyoyama, Hiroyuki; Hirata, Yusuke; Kikuchi, Satoshi; Sakai, Kosuke; Saito, Yuriko; Mikami, Shintaro; Moriyama, Gaku; Yanagita, Hisami; Watanabe, Wataru; Otani, Katharina; Honda, Norinari; Uematsu, Kazutsugu
2017-01-01
Xenon-enhanced dual-energy computed tomography (xenon-enhanced CT) can provide lung ventilation maps that may be useful for assessing structural and functional abnormalities of the lung. Xenon-enhanced CT has been performed using a multiple-breath-hold technique during xenon washout. We recently developed xenon-enhanced CT using a single-breath-hold technique to assess ventilation. We sought to evaluate whether xenon-enhanced CT using a single-breath-hold technique correlates with pulmonary function testing (PFT) results.Twenty-six patients, including 11 chronic obstructive pulmonary disease (COPD) patients, underwent xenon-enhanced CT and PFT. Three of the COPD patients underwent xenon-enhanced CT before and after bronchodilator treatment. Images from xenon-CT were obtained by dual-source CT during a breath-hold after a single vital-capacity inspiration of a xenon-oxygen gas mixture. Image postprocessing by 3-material decomposition generated conventional CT and xenon-enhanced images.Low-attenuation areas on xenon images matched low-attenuation areas on conventional CT in 21 cases but matched normal-attenuation areas in 5 cases. Volumes of Hounsfield unit (HU) histograms of xenon images correlated moderately and highly with vital capacity (VC) and total lung capacity (TLC), respectively (r = 0.68 and 0.85). Means and modes of histograms weakly correlated with VC (r = 0.39 and 0.38), moderately with forced expiratory volume in 1 second (FEV1) (r = 0.59 and 0.56), weakly with the ratio of FEV1 to FVC (r = 0.46 and 0.42), and moderately with the ratio of FEV1 to its predicted value (r = 0.64 and 0.60). Mode and volume of histograms increased in 2 COPD patients after the improvement of FEV1 with bronchodilators. Inhalation of xenon gas caused no adverse effects.Xenon-enhanced CT using a single-breath-hold technique depicted functional abnormalities not detectable on thin-slice CT. Mode, mean, and volume of HU histograms of xenon images reflected pulmonary function. Xenon images obtained with xenon-enhanced CT using a single-breath-hold technique can qualitatively depict pulmonary ventilation. A larger study comprising only COPD patients should be conducted, as xenon-enhanced CT is expected to be a promising technique for the management of COPD.
Mediating pathways from central obesity to childhood asthma: a population-based longitudinal study.
Chih, An-Hsuan; Chen, Yang-Ching; Tu, Yu-Kang; Huang, Kuo-Chin; Chiu, Tai-Yuan; Lee, Yungling Leo
2016-09-01
The mediating pathways linking obesity and asthma are largely unknown. We aimed to investigate the mediating pathways and to search for the most prominent pathological mechanism between central obesity and childhood asthma.In the Taiwan Children Health Study, we collected data on an open cohort of children aged 9-13 years. Children's respiratory outcomes, atopic conditions, obesity measures and pulmonary function were surveyed annually between 2010 and 2012. Exhaled nitric oxide fraction concentrations were recorded in 2012. Generalised estimating equations and general linear models were used to examine the associations between central obesity, possible mediators and asthma. Structural equation models were applied to investigate the pathways that mediate the link between central obesity and asthma.Central obesity (waist-to-hip ratio) most accurately predicted childhood asthma. In the active asthma model, the percentage of mediation was 28.6% for pulmonary function, 18.1% for atopy and 5.7% for airway inflammation. The percentage of mediation for pulmonary function was 40.2% in the lifetime wheeze model. Pulmonary function was responsible for the greatest percentage of mediation among the three mediators in both models.Decline in pulmonary function is the most important pathway in central obesity related asthma. Pulmonary function screening should be applied to obese children for asthma risk prediction. Copyright ©ERS 2016.
Severgnini, Paolo; Selmo, Gabriele; Lanza, Christian; Chiesa, Alessandro; Frigerio, Alice; Bacuzzi, Alessandro; Dionigi, Gianlorenzo; Novario, Raffaele; Gregoretti, Cesare; de Abreu, Marcelo Gama; Schultz, Marcus J; Jaber, Samir; Futier, Emmanuel; Chiaranda, Maurizio; Pelosi, Paolo
2013-06-01
The impact of intraoperative ventilation on postoperative pulmonary complications is not defined. The authors aimed at determining the effectiveness of protective mechanical ventilation during open abdominal surgery on a modified Clinical Pulmonary Infection Score as primary outcome and postoperative pulmonary function. Prospective randomized, open-label, clinical trial performed in 56 patients scheduled to undergo elective open abdominal surgery lasting more than 2 h. Patients were assigned by envelopes to mechanical ventilation with tidal volume of 9 ml/kg ideal body weight and zero-positive end-expiratory pressure (standard ventilation strategy) or tidal volumes of 7 ml/kg ideal body weight, 10 cm H2O positive end-expiratory pressure, and recruitment maneuvers (protective ventilation strategy). Modified Clinical Pulmonary Infection Score, gas exchange, and pulmonary functional tests were measured preoperatively, as well as at days 1, 3, and 5 after surgery. Patients ventilated protectively showed better pulmonary functional tests up to day 5, fewer alterations on chest x-ray up to day 3 and higher arterial oxygenation in air at days 1, 3, and 5 (mmHg; mean ± SD): 77.1 ± 13.0 versus 64.9 ± 11.3 (P = 0.0006), 80.5 ± 10.1 versus 69.7 ± 9.3 (P = 0.0002), and 82.1 ± 10.7 versus 78.5 ± 21.7 (P = 0.44) respectively. The modified Clinical Pulmonary Infection Score was lower in the protective ventilation strategy at days 1 and 3. The percentage of patients in hospital at day 28 after surgery was not different between groups (7 vs. 15% respectively, P = 0.42). A protective ventilation strategy during abdominal surgery lasting more than 2 h improved respiratory function and reduced the modified Clinical Pulmonary Infection Score without affecting length of hospital stay.
Prediction of pulmonary hypertension in idiopathic pulmonary fibrosis☆
Zisman, David A.; Ross, David J.; Belperio, John A.; Saggar, Rajan; Lynch, Joseph P.; Ardehali, Abbas; Karlamangla, Arun S.
2007-01-01
Summary Background Reliable, noninvasive approaches to the diagnosis of pulmonary hypertension in idiopathic pulmonary fibrosis are needed. We tested the hypothesis that the forced vital capacity to diffusing capacity ratio and room air resting pulse oximetry may be combined to predict mean pulmonary artery pressure (MPAP) in idiopathic pulmonary fibrosis. Methods Sixty-one idiopathic pulmonary fibrosis patients with available right-heart catheterization were studied. We regressed measured MPAP as a continuous variable on pulse oximetry (SpO2) and percent predicted forced vital capacity (FVC) to percent-predicted diffusing capacity ratio (% FVC/% DLco) in a multivariable linear regression model. Results Linear regression generated the following equation: MPAP = −11.9+0.272 × SpO2+0.0659 × (100−SpO2)2+3.06 × (% FVC/% DLco); adjusted R2 = 0.55, p<0.0001. The sensitivity, specificity, positive predictive and negative predictive value of model-predicted pulmonary hypertension were 71% (95% confidence interval (CI): 50–89%), 81% (95% CI: 68–92%), 71% (95% CI: 51–87%) and 81% (95% CI: 68–94%). Conclusions A pulmonary hypertension predictor based on room air resting pulse oximetry and FVC to diffusing capacity ratio has a relatively high negative predictive value. However, this model will require external validation before it can be used in clinical practice. PMID:17604151
Update on diagnosis and treatment of idiopathic pulmonary fibrosis
Baddini-Martinez, José; Baldi, Bruno Guedes; da Costa, Cláudia Henrique; Jezler, Sérgio; Lima, Mariana Silva; Rufino, Rogério
2015-01-01
Idiopathic pulmonary fibrosis is a type of chronic fibrosing interstitial pneumonia, of unknown etiology, which is associated with a progressive decrease in pulmonary function and with high mortality rates. Interest in and knowledge of this disorder have grown substantially in recent years. In this review article, we broadly discuss distinct aspects related to the diagnosis and treatment of idiopathic pulmonary fibrosis. We list the current diagnostic criteria and describe the therapeutic approaches currently available, symptomatic treatments, the action of new drugs that are effective in slowing the decline in pulmonary function, and indications for lung transplantation. PMID:26578138
Wang, Shengyu; Gong, Wei; Tian, Yao
2016-05-01
Chronic obstructive pulmonary disease (COPD) is projected to be the third leading cause of death by 2020. Early detection and screening may alter the course and prognosis associated with lung disease. We investigated the effectiveness of a voluntary public lung function screening program and factors that had a predictive value for asymptomatic COPD in Xi'an, China. Pulmonary function testing (PFT) was conducted on volunteers recruited from four community centers in Xi'an, China, between July and August 2012. Participants underwent three forced vital capacity maneuvers. The maneuver with the best forced expiratory volume in first second was retained. Participants filled out a medical history and environmental exposure survey before undergoing the PFT. Patients who self-reported lung disease on the health survey were excluded from the analysis. Logistical regression was used to determine associations with airway obstruction. A total of 803 volunteers participated in this study, and 33 subjects were excluded as the participants did not meet the requirements of PFT. Of the 770 volunteers, 44 participants had been diagnosed with chronic respiratory diseases previously, and 144 participants (18.7%) met COPD criteria. Four hundred forty-four participants did not self-report any respiratory symptoms, and the remaining 282 participants self-reported respiratory symptoms. Of the asymptomatic participants, 98 volunteers had PFT results that were consistent with COPD and 68.1% of asymptomatic participants were undiagnosed. A greater percentage of women than men had moderate or severe airway obstruction (p = 0.004).Only smoking status (odds ratio = 2.64, 95% confidence interval 1.20-6.04) was associated with asymptomatic COPD. Voluntary public lung function screening programs in China are likely to identify a large number of undiagnosed, asymptomatic COPD. Smoking status is associated with airway obstruction and a greater percentage of women than men had moderate or severe airway obstruction. © The Author(s) 2016.
Obstructive Airways Disease With Air Trapping Among Firefighters Exposed to World Trade Center Dust
Weiden, Michael D.; Ferrier, Natalia; Nolan, Anna; Rom, William N.; Comfort, Ashley; Gustave, Jackson; Zeig-Owens, Rachel; Zheng, Shugi; Goldring, Roberta M.; Berger, Kenneth I.; Cosenza, Kaitlyn; Lee, Roy; Webber, Mayris P.; Kelly, Kerry J.; Aldrich, Thomas K.
2010-01-01
Background: The World Trade Center (WTC) collapse produced a massive exposure to respirable particulates in New York City Fire Department (FDNY) rescue workers. This group had spirometry examinations pre-September 11, 2001, and post-September 11, 2001, demonstrating declines in lung function with parallel declines in FEV1 and FVC. To date, the underlying pathophysiologic cause for this has been open to question. Methods: Of 13,234 participants in the FDNY-WTC Monitoring Program, 1,720 (13%) were referred for pulmonary subspecialty evaluation at a single institution. Evaluation included 919 full pulmonary function tests, 1,219 methacholine challenge tests, and 982 high-resolution chest CT scans. Results: At pulmonary evaluation (median 34 months post-September 11, 2001), median values were FEV1 93% predicted (interquartile range [IQR], 83%-101%), FVC 98% predicted (IQR, 89%-106%), and FEV1/FVC 0.78 (IQR, 0.72-0.82). The residual volume (RV) was 123% predicted (IQR, 106%-147%) with nearly all participants having normal total lung capacity, functional residual capacity, and diffusing capacity of carbon monoxide. Also, 1,051/1,720 (59%) had obstructive airways disease based on at least one of the following: FEV1/FVC, bronchodilator responsiveness, hyperreactivity, or elevated RV. After adjusting for age, gender, race, height and weight, and tobacco use, the decline in FEV1 post-September 11, 2001, was significantly correlated with increased RV percent predicted (P < .0001), increased bronchodilator responsiveness (P < .0001), and increased hyperreactivity (P = .0056). CT scans demonstrated bronchial wall thickening that was significantly associated with the decline in FEV1 post-September 11, 2001 (P = .024), increases in hyperreactivity (P < .0001), and increases in RV (P < .0001). Few had evidence for interstitial disease. Conclusions: Airways obstruction was the predominant physiologic finding underlying the reduction in lung function post-September 11, 2001, in FDNY WTC rescue workers presenting for pulmonary evaluation. PMID:19820077
Effect of occupational silica exposure on pulmonary function.
Hertzberg, Vicki Stover; Rosenman, Kenneth D; Reilly, Mary Jo; Rice, Carol H
2002-08-01
To assess the effect of occupational silica exposure on pulmonary function. Epidemiologic evaluation based on employee interview, plant walk-through, and information abstracted from company medical records, employment records, and industrial hygiene measurements. Drawn from 1,072 current and former hourly wage workers employed before January 1, 1986. Thirty-six individuals with radiographic evidence of parenchymal changes consistent with asbestosis or silicosis were excluded. In addition, eight individuals whose race was listed as other than white or black were excluded. Analysis of spirometry data (FVC, FEV1, FEV1/FVC) only using the test results that met American Thoracic Society criteria for reproducibility and acceptability shows decreasing percent-predicted FVC and FEV1 and decreasing FEV1/FVC in relationship to increasing silica exposure among smokers. Logistic regression analyses of abnormal FVC and abnormal FEV1 values (where abnormal is defined as < 95% confidence limit for predicted using the Knudson prediction equations) show odds ratios of 1.49 and 1.68, respectively, for occurrence of abnormal result with 40 years of exposure at the Occupational Safety and Health Administration (OSHA)-allowable level of 0.1 mg/m3. Longitudinal analyses of FVC and FEV1 measurements show a 1.6 mL/yr and 1.1 mL/yr, respectively, decline per milligram/cubic meter mean silica exposure (p = 0.011 and p = 0.001, respectively). All analyses were adjusted for weight, height, age, ethnicity, smoking status, and other silica exposures. Systematic problems leading to measurement error were possible, but would have been nondifferential in effect and not related to silica measurements. There is a consistent association between increased pulmonary function abnormalities and estimated measures of cumulative silica exposure within the current allowable OSHA regulatory level. Despite concerns about the quality control of the pulmonary function measurements use in these analyses, our results support the need to lower allowable air levels of silica and increase efforts to encourage cessation of cigarette smoking among silica-exposed workers.
Bertoli, L; Mantero, A; Alpago, R; Graziina, A; Tamponi, M; Pezzano, A
1989-01-01
Thirty-three patients suffering from chronic obstructive lung disease (COLD) were submitted to right heart two-dimensional echocardiographic (2D-ECHO) and hemodynamic study. By the subcostal approach, the right ventricle outflow tract including the pulmonary vessels was visualized in 85% of the patients. Most parameters measured on the right ventricle and pulmonary vessels were significantly higher than those recorded in the healthy control group. Very significant correlations were observed between the mean pulmonary artery pressure (PAP) and the following 2D-ECHO parameters: diameter of the pulmonary artery at valve level (r = 0.62; p less than 0.001); supravalvular diameter of the pulmonary artery (r = 0.44; p less than 0.03); diameter of the left branch of the pulmonary artery (r = 0.48; p less than 0.05); diameter of the right branch of the pulmonary artery (r = 0.39; p less than 0.05), and between the PAP and PaO2 (r = -0.66; p less than 0.001). Furthermore, the sensitivity, specificity, and accuracy of 2D-ECHO measurements were calculated to assess the presence of pulmonary hypertension. Overall sensitivity was 65%, specificity 75%, and accuracy 67%. However, by combining the value of PaO2 with that of the pulmonary valve by means of the multiple regression analysis, sensitivity increased to 84% in identifying pulmonary hypertension. Such data demonstrate that the 2D-ECHO study of the right heart in COLD patients has to carefully measure the dimensions of the pulmonary valve and the great pulmonary vessels, as their modification are mainly linked with the presence of pulmonary hypertension.(ABSTRACT TRUNCATED AT 250 WORDS)
Airway and Pulmonary β2-Adrenergic Vasodilatory Function in Current Smokers and Never Smokers.
Hurwitz, Barry E; Mendes, Eliana S; Schmid, Andreas; Parker, Meela; Arana, Johana; Gonzalez, Alex; Wanner, Adam
2017-03-01
Cigarette smoking has been associated with diminished vasodilatory function in the airway circulation. It is possible that cigarette smoking similarly affects the pulmonary circulation before resting pulmonary circulatory abnormalities become manifested. The aim of this study was to compare the acute effect of inhaled albuterol on airway and pulmonary hemodynamic function as an index of β 2 -adrenoceptor-mediated vasodilation in smokers and never smokers. In 30 adults, airway and pulmonary vascular function was assessed before and 15 min after albuterol inhalation (270 μg). From mean systemic arterial pressure, cardiac output, airway blood flow, and mean pulmonary arterial pressure, airway vascular resistance (AVR) and pulmonary vascular resistance (PVR) were derived. Albuterol induced a substantial drop in mean (± SE) PVR (-67.2% ± 5%), with no difference between groups. In contrast, the albuterol-induced decrease in AVR was significantly greater in never smokers than in smokers (-28.6% ± 3% vs -3.1% ± 6%; P < .02). These results are consistent with a dysfunction in a β 2 -adrenergic signaling pathway mediating vasorelaxation in the airway circulation of current smokers. The vasodilatory deficit in the airway circulation but not in the pulmonary circulation could be related to local differences in the impact of cigarette smoke on the vascular endothelium. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Li, X; Dai, W R; Li, L; Liu, W F; Yang, Z X; Xie, L
2017-11-20
Objective: To investigate the clinical features of pneumoconiosis complicated with pulmo-nary emphysema. Methods: selected 868 patients with pneumoconiosis were selected from December 2015 to December 2016 in Hunan occupational disease prevention and treatment hospital. Collected the results of high-resolution spiral CT, arterial blood gas, ECG, pulmonary function and MRC score. The subjects were divided into pneumoconiosis complicated with pulmonary emphysema group and simple pneumoconiosis group accord-ing to the results of HRCT. The smoking, MRC score, pulmonary function, blood gas and complications were compared. Results: A total of 868 patients were enrolled in the study. Emphysema 232 people, accounting for 26.73%. The incidence of emphysema in the first phase of pneumoconiosis was 12.69%, and the incidence rate of emphysema in pneumoconiosis was 17.03%, The incidence of three Stage pneumoconiosis was highest, up to 60.76%, the incidence of emphysema increased with the increase of stages of pneumoconiosis ( P =0.000) .The smoking index of pneumoconiosis combined with emphysema group was significantly higher than that of simple pneumoconiosis group ( P <0.01) . The MRC score of pneumoconiosis complicated with pulmonary em-physema group was higher than that of simple pneumoconiosis group ( P =0.000) . In pneumoconiosis complicat-ed with pulmonary emphysema group the FEV(1.0)%, FVC%, FEV(1.0)/FVC, DLCO%, oxygen partial pressure were significantly lower than that of simple pneumoconiosis group ( P ≤0.05) . The combined rate of Bullae of lung in pneumoconiosis complicated with pulmonary emphysema group was higher than that of simple pneumo-coniosis group ( P <0.01) . Conclusion: pneumoconiosis stage and smoking. Patients with pneumoconiosis com-plicated with pulmonary emphysema had heavier breathing difficulties, more serious pulmonary function and active endurance, the degree of hypoxia is more serious, and had a higher incidence of complications. The pul-monary function of pneumoconiosis complicated with pulmonary emphysema is not consistent with the typical CPFE.
Proença, Martin; Braun, Fabian; Solà, Josep; Adler, Andy; Lemay, Mathieu; Thiran, Jean-Philippe; Rimoldi, Stefano F
2016-06-01
Monitoring of pulmonary artery pressure (PAP) in pulmonary hypertensive patients is currently limited to invasive solutions. We investigate a novel non-invasive approach for continuous monitoring of PAP, based on electrical impedance tomography (EIT), a safe, low-cost and non-invasive imaging technology. EIT recordings were performed in three healthy subjects undergoing hypoxia-induced PAP variations. The pulmonary pulse arrival time (PAT), a timing parameter physiologically linked to the PAP, was automatically calculated from the EIT signals. Values were compared to systolic PAP values from Doppler echocardiography, and yielded strong correlation scores ([Formula: see text]) for all three subjects. Results suggest the feasibility of non-invasive, unsupervised monitoring of PAP.
Pulmonary Morbidity in Infancy after Exposure to Chorioamnionitis in Late Preterm Infants
McDowell, Karen M.; Jobe, Alan H.; Fenchel, Matthew; Hardie, William D.; Gisslen, Tate; Young, Lisa R.; Chougnet, Claire A.; Davis, Stephanie D.
2016-01-01
Rationale: Chorioamnionitis is an important cause of preterm birth, but its impact on postnatal outcomes is understudied. Objectives: To evaluate whether fetal exposure to inflammation is associated with adverse pulmonary outcomes at 6 to 12 months’ chronological age in infants born moderate to late preterm. Methods: Infants born between 32 and 36 weeks’ gestational age were prospectively recruited (N = 184). Chorioamnionitis was diagnosed by placenta and umbilical cord histology. Select cytokines were measured in samples of cord blood. Validated pulmonary questionnaires were administered (n = 184), and infant pulmonary function testing was performed (n = 69) between 6 and 12 months’ chronological age by the raised volume rapid thoracoabdominal compression technique. Measurements and Main Results: A total of 25% of participants had chorioamnionitis. Although infant pulmonary function testing variables were lower in infants born preterm compared with historical normative data for term infants, there were no differences between infants with chorioamnionitis (n = 20) and those without (n = 49). Boys and black infants had lower infant pulmonary function testing measurements than girls and white infants, respectively. Chorioamnionitis exposure was associated independently with wheeze (odds ratio [OR], 2.08) and respiratory-related physician visits (OR, 3.18) in the first year of life. Infants exposed to severe chorioamnionitis had increased levels of cord blood IL-6 and greater pulmonary morbidity at age 6 to 12 months than those exposed to mild chorioamnionitis. Elevated IL-6 was associated with significantly more respiratory problems (OR, 3.23). Conclusions: In infants born moderate or late preterm, elevated cord blood IL-6 and exposure to histologically identified chorioamnionitis was associated with respiratory morbidity during infancy without significant changes in infant pulmonary function testing measurements. Black compared with white and boy compared with girl infants had lower infant pulmonary function testing measurements and worse pulmonary outcomes. PMID:27015030
Nasal mucociliary transportability of male and female smokers.
Uzeloto, Juliana Souza; Ramos, Dionei; C F Freire, Ana Paula; G D Christofaro, Diego; Mara C Ramos, Ercy
Female smoker's present increased susceptibility to several diseases when compared to the opposite gender. However, there are no studies showing differences in nasal mucociliary transport behavior between male and female smokers. To compare the nasal mucociliary transportability in male and female smokers and non-smokers, taking into consideration age, anthropometric data, smoking load and pulmonary function. The analysis included 139 individuals (33 men and 37 women smokers and 32 men and 37 women non-smokers). All participants answered an initial interview to obtain personal data and smoking load. Anthropometric data and carbon monoxide in the exhaled air were assessed. Individuals also performed pulmonary function test and Saccharin Transit Time test. To compare saccharin transit time values between men and women, smokers and non-smokers, stratification of all independent variables was performed (sociodemographic, smoking and respiratory variables) into two categories: below and above the median values. There was no difference between men and women, smokers and non-smokers, regarding nasal mucociliary transportability. Significant differences were only observed between non-smokers. Among those with less forced vital capacity values (<97.37% of predicted), women presented mucociliary transport faster than men. Moreover, it was observed influence of BMI and COex (women smokers), FCV and FEV1 (men non-smokers) and FEF 25-75% (women non-smokers) on saccharin transit time values. Based on the findings of this study, nasal mucociliary transport in male and female adult smokers, apparently healthy, are similar. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Inami, Takumi; Kataoka, Masaharu; Shimura, Nobuhiko; Ishiguro, Haruhisa; Yanagisawa, Ryoji; Taguchi, Hiroki; Fukuda, Keiichi; Yoshino, Hideaki; Satoh, Toru
2013-07-01
This study sought to identify useful predictors for hemodynamic improvement and risk of reperfusion pulmonary edema (RPE), a major complication of this procedure. Percutaneous transluminal pulmonary angioplasty (PTPA) has been reported to be effective for the treatment of chronic thromboembolic pulmonary hypertension (CTEPH). PTPA has not been widespread because RPE has not been well predicted. We included 140 consecutive procedures in 54 patients with CTEPH. The flow appearance of the target vessels was graded into 4 groups (Pulmonary Flow Grade), and we proposed PEPSI (Pulmonary Edema Predictive Scoring Index) = (sum total change of Pulmonary Flow Grade scores) × (baseline pulmonary vascular resistance). Correlations between occurrence of RPE and 11 variables, including hemodynamic parameters, number of target vessels, and PEPSI, were analyzed. Hemodynamic parameters significantly improved after median observation period of 6.4 months, and the sum total changes in Pulmonary Flow Grade scores were significantly correlated with the improvement in hemodynamics. Multivariate analysis revealed that PEPSI was the strongest factor correlated with the occurrence of RPE (p < 0.0001). Receiver-operating characteristic curve analysis demonstrated PEPSI to be a useful marker of the risk of RPE (cutoff value 35.4, negative predictive value 92.3%). Pulmonary Flow Grade score is useful in determining therapeutic efficacy, and PEPSI is highly supportive to reduce the risk of RPE after PTPA. Using these 2 indexes, PTPA could become a safe and common therapeutic strategy for CTEPH. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Yamada, Yoshitake; Jinzaki, Masahiro; Hashimoto, Masahiro; Shiomi, Eisuke; Abe, Takayuki; Kuribayashi, Sachio; Ogawa, Kenji
2013-08-01
To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA-950) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P < 0.0001) of tomosynthesis than radiography for the detection of pulmonary emphysema. The average sensitivity, specificity, positive predictive value and negative predictive value of tomosynthesis were 0.875, 0.968, 0.955 and 0.910, respectively, whereas the values for radiography were 0.479, 0.913, 0.815 and 0.697, respectively. For both tomosynthesis and radiography, the sensitivity increased with increasing LAA-950. The diagnostic performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA-950. • Tomosynthesis showed significantly better diagnostic performance for pulmonary emphysema than radiography. • Interobserver agreement for tomosynthesis was significantly higher than that for radiography. • Sensitivity increased with increasing LAA -950 in both tomosynthesis and radiography. • Tomosynthesis imparts a similar radiation dose to two projection chest radiography. • Radiation dose and cost of tomosynthesis are lower than those of MDCT.
Mukherjee, Sayali; Roychoudhury, Sanghita; Siddique, Shabana; Banerjee, Madhuchanda; Bhattacharya, Purba; Lahiri, Twisha; Ray, Manas Ranjan
2014-12-01
The impact of chronic exposure to smoke from biomass burning on respiratory health has been examined. Six-hundred and eighty-one non-smoking women (median age 35 years) from eastern India who cook exclusively with biomass (wood, dung and crop residues) and 438 age-matched women from similar neighborhood who cook with liquefied petroleum gas (LPG) were examined. Pulmonary function test was done by spirometry. The concentrations of particulate matter having diameter of < 10 µm (PM10) and < 2.5 µm (PM2.5) in indoor air was measured by real-time aerosol monitor. Compared with LPG users, biomass users had greater prevalence of upper (50.9 versus 28.5%) and lower respiratory symptoms (71.8 versus 30.8%) and dyspnea (58.4 versus 19.9%). They showed reduction in all parameters measured by spirometer especially in mid-expiratory volume. PM10 and PM2.5 concentration in biomass using kitchen were 2-3-times more than LPG-using kitchen, and the decline in spirometry values was positively associated PM10 and PM2.5 levels in indoor air after controlling education, family income and kitchen location as potential confounders. Overall, 29.7% of biomass users and 16.4% of LPG users had deficient lung function, and restrictive type of deficiency was predominant. Chronic obstructive pulmonary disease (COPD) was diagnosed in 4.6% of biomass and 0.9% of LPG users. Women who predominantly used dung cake and did not possess separate kitchen had poorer lung function. Cumulative exposure to biomass smoke causes lung function decrement and facilitates COPD development even in non-smoking and relatively young pre-menopausal women.
Ito, Hiroki; Murata, Masaya; Ide, Yujiro; Sugano, Mikio; Kanno, Kazuyoshi; Imai, Kenta; Ishido, Motonori; Fukuba, Ryohei; Sakamoto, Kisaburo
2016-01-01
OBJECTIVES Fontan candidates with mixed totally anomalous pulmonary venous connection often have postoperative pulmonary venous obstruction after cavopulmonary anastomosis. Because some pulmonary venous obstructions have no intimal hypertrophy at reoperation, we considered such pulmonary venous obstructions to be caused by 3D deformities arising from dissection or mobilization of the vessels, and hypothesized that keeping the pulmonary venous branches in a natural position could avoid such obstruction. Here, we evaluated a modified hemi-Fontan strategy consisting of minimal dissection with no division of vessels and patch separation between systemic and pulmonary venous flow. METHODS We retrospectively reviewed clinical records of infants with a functional single ventricle and supracardiac anomalous pulmonary venous connection who had undergone this procedure between 2002 and 2012. RESULTS Nine infants underwent this procedure (median age, 5.6 months; range 3.2–30), all with right atrial isomerism and several pulmonary venous branches directly and separately connecting to the superior vena cava. In 5 patients, all pulmonary veins drained into the superior vena cava; in 1, the right pulmonary veins drained into the superior vena cava and in 3, a pulmonary venous branch drained into the superior vena cava. The median follow-up was 6.9 years (0.8–13 years). Three patients underwent reoperation for postoperative pulmonary venous obstruction caused by intimal hypertrophy; however, we confirmed no pulmonary venous obstruction caused by 3D deformities on the pulmonary venous branches connecting separately to the superior vena cava. Although 2 patients were effectively relieved from pulmonary venous obstruction, 1 died due to recurrent pulmonary venous obstruction. There was no late death and no sinus-node dysfunction. Eight patients underwent successful Fontan operation and catheterization. The median interval from the Fontan operation to the latest catheterization was 3.7 years (0.9–3.7 years). The median arterial oxygen saturation was 94% (91–97%) and the central venous pressure was 12 mmHg (8–14 mmHg); no deficiency of pulmonary arteries and veins was noted. CONCLUSIONS For patients with functional single ventricle and anomalous pulmonary venous connections to the superior vena cava, our novel strategy of second-stage palliation could avoid postoperative pulmonary venous obstruction caused by 3D deformities, but may not eliminate pulmonary venous obstruction caused by intimal hypertrophy. PMID:26860898
Westerdahl, Elisabeth; Lindmark, Birgitta; Eriksson, Tomas; Friberg, Orjan; Hedenstierna, Göran; Tenling, Arne
2005-11-01
To investigate the effects of deep-breathing exercises on pulmonary function, atelectasis, and arterial blood gas levels after coronary artery bypass graft (CABG) surgery. In a prospective, randomized trial, patients performing deep-breathing exercises (n = 48) were compared to a control group (n = 42) who performed no breathing exercises postoperatively. Patient management was similar in the groups in terms of assessment, positioning, and mobility. The patients in the deep-breathing group were instructed to perform breathing exercises hourly during daytime for the first 4 postoperative days. The exercises consisted of 30 slow, deep breaths performed with a positive expiratory pressure blow-bottle device (+ 10 cm H(2)O). Spirometric measurements, spiral CT (three transverse levels), arterial blood gas analysis, and scoring of subjective experience of the breathing exercises were performed on the fourth postoperative day. Atelectasis was only half the size in the deep-breathing group compared to the control group, amounting to 2.6 +/- 2.2% vs 4.7 +/- 5.7% (p = 0.045) at the basal level and 0.1 +/- 0.2% vs 0.3 +/- 0.5% (mean +/- SD) [p = 0.01] at the apical level. Compared to the control subjects, the patients in the deep-breathing group had a significantly smaller reduction in FVC (to 71 +/- 12%, vs 64 +/- 13% of the preoperative values; p = 0.01) and FEV(1) (to 71 +/- 11%, vs 65 +/- 13% of the preoperative values; p = 0.01). Arterial oxygen tension, carbon dioxide tension, fever, or length of ICU or hospital stay did not differ between the groups. In the deep-breathing group, 72% of the patients experienced a subjective benefit from the exercises. Patients performing deep-breathing exercises after CABG surgery had significantly smaller atelectatic areas and better pulmonary function on the fourth postoperative day compared to a control group performing no exercises.
Chaosuwannakit, N; Makarawate, P
2018-01-01
Primary evaluation of patients with pulmonary atresia with ventricular septal defect (PA-VSD) traditionally relies upon echocardiography and conventional cardiac angiography (CCA). Cardiac angiography is considered the gold standard for delineation of anatomy in children with PA-VSD. Data comparing CCA and dual-source multidetector-row computed tomography angiography (MDCT) in PA-VSD patients is limited. The objective of this study was to test the hypothesis that MDCT is equivalent to CCA for anatomic delineation in these patients. Twenty-eight patients with PA-VSD underwent CCA and MDCT in close proximity to each other without interval therapy. A retrospective review of these 28 patients was performed. All MDCT data of pulmonary artery morphology, major aortopulmonary collateral arteries (MAPCAs) and type of blood supply (dual vs. single supply) were evaluated by blinded experts and results were compared with CCA. Twenty-eight patients had adequate size right and left pulmonary arteries (21 confluent and 7 non-confluent). Seven patients had complete absence of native pulmonary artery and 3 patients had stenosis of distal branches of pulmonary arteries; all had MAPCAs from descending thoracic aorta and/or subclavian arteries. Sensitivity, specificity, positive and negative predictive value of MDCT for detecting confluent of pulmonary arteries, absence of native pulmonary artery and stenosis of pulmonary arteries were all 100%. Moreover, accuracy of detecting MAPCAs was excellent. These results suggest that MDCT and CCA are equivalent in their ability to delineate pulmonary artery anatomy and MAPCAs. Dual source MDCT provides high diagnostic accuracy in evaluation of pulmonary blood supply in patients with PA-VSD and allows precise characterisation of the condition of pulmonary arteries and MAPCAs which is of paramount importance in managing patients with PA-VSD. (Folia Morphol 2018; 77, 1: 116-122).
Outcome of influenza infection managed with oseltamivir in lung transplant recipients.
Ison, Michael G; Sharma, Amita; Shepard, Jo-Anne O; Wain, John C; Ginns, Leo C
2008-03-01
Influenza causes significant morbidity and mortality in lung transplant recipients and likely predisposes to obliterative bronchiolitis. Neuraminidase inhibitors shorten the duration of symptoms and virus shedding and the number of antibiotic-requiring complications in ambulatory immunocompetent patients, although the efficacy of these agents in lung transplant recipients has not been assessed previously. In this study, 9 lung transplant patients who were treated with oseltamivir for influenza infections were identified and analyzed retrospectively. Oseltamivir was well tolerated. Infection resolved in all patients and there were no deaths. Two patients developed pneumonia shortly after their influenza infection and both responded to antibiotic therapy. None of the patients had persistent abnormalities noted on chest imaging and most did not show significant changes on pulmonary function testing. Two patients with the lowest pulmonary function test (PFT) values pre-infection had persistent defects after infection. Oseltamivir is well tolerated in lung transplant recipients and may reduce the risk of complications, although further studies are warranted.
[Impaired lung function in patients with moderate chronic obstructive bronchitis].
Nefedov, V B; Popova, L A; Shergina, E A
2004-01-01
VC, FVC, FEV1, FEV1/VC%, PEF, MEF25, MEF50, MEF75, TLC, TGV, RV, Raw, Rin, Rex, DLCO-SS, paO2 and paCO2 were determined in 22 patients with moderate chronic obstructive bronchitis (FEV1, 79-50% of the normal value). All the patients were found to have impaired bronchial patency, 90.9% of the patients had lung volume and capacity changes; pulmonary gas exchange dysfunction was present in 72.7%. Bronchial patency impairments were manifested by a decrease in FEV1, FEV1/VC%, PEF, MEF25, MEF50, MEF75, and an increase in Raw, Rin, Rex. Changes in the lung volumes and capacities appeared as higher RV, TGV, TLC, lower VC and FVC. Pulmonary gas exchange dysfunction showed up as a reduction in pO2 and DLCO-SS a reduction and an increase in paCO2. The magnitude of the functional changes observed in most patients was low. Significant and pronounced disorders were seen in one third of the patients.
Korff, Susanne; Enders-Gier, Patricia; Uhlmann, Lorenz; Aurich, Matthias; Greiner, Sebastian; Hirschberg, Kristof; Katus, Hugo A; Mereles, Derliz
2018-03-19
Pulmonary hypertension is a marker of disease severity. Exercise Doppler echocardiography (EDE) has proven to be feasible and reliable to assess pulmonary pressure. Increase in systolic pulmonary artery pressure (sPAP) has diagnostic and prognostic value in controlled studies. However, its value when assessed during routine examination in patients with cardiopulmonary diseases and resting sPAP > 35 mmHg is not clearly defined. Clinical documentation and offline reevaluation of digitally stored EDE examinations of patients with appropriate clinical indications for EDE were analyzed. N = 278 patients with sPAP at rest > 35 mmHg met inclusion criteria. One patient was lost to follow-up. Mean age of patients was 72 ± 10 years, 178 (64%) of the study population were men. There were no relevant differences among survivors and non-survivors concerning comorbidities. Exercise performance (3.6 ± 1.2 vs. 4.9 ± 1.4 MET, p < 0.001) was lower, whereas sPAP during exercise was higher (67.3 ± 14.7 vs. 62.1 ± 13.2 mmHg, p = 0.027) in non-survivors. Univariate predictors of all-cause mortality were NYHA functional class III (HR = 2.56, p < 0.001), ≥ 2-vessels coronary artery disease (CAD) (HR = 1.93, p = 0.04), left atrial diameter > 45 mm (HR = 2.58, p < 0.001), rest sPAP > 42 mmHg (HR = 1.94, p = 0.010) and ΔsPAP increase ≥ 0.23 mmHg/Watt (HF = 1.92, p = 0.010). After multivariate analysis, NYHA functional class III (HR = 2.35, p < 0.001), LA diameter (HR = 2.28, p = 0.003) and sPAP increase ≥ 0.23 mmHg/Watt (HF = 2.19, p = 0.002) remained significant predictors of mortality, whereas a double product (HR = 0.42, p = 0.005) was associated with better prognosis. sPAP assessment during routine EDE provides relevant prognostic information comparable to findings in studies in selected populations. A higher sPAP increase at lower exercise performance shows significant association with increased of mortality.
Fot, Evgenia V; Izotova, Natalia N; Yudina, Anjelika S; Smetkin, Aleksei A; Kuzkov, Vsevolod V; Kirov, Mikhail Y
2017-01-01
The early warning scores may increase the safety of perioperative period. The objective of this study was to assess the diagnostic and predictive role of Integrated Pulmonary Index (IPI) after off-pump coronary artery bypass grafting (OPCAB). Forty adult patients undergoing elective OPCAB were enrolled into a single-center prospective observational study. We assessed respiratory function using IPI that includes oxygen saturation, end-tidal CO 2 , respiratory rate, and pulse rate. In addition, we evaluated blood gas analyses and hemodynamics, including ECG, invasive arterial pressure, and cardiac index. The measurements were performed after transfer to the intensive care unit, after spontaneous breathing trial and at 2, 6, 12, and 18 h after extubation. The value of IPI registered during respiratory support correlated weakly with cardiac index (rho = 0.4; p = 0.04) and ScvO 2 (rho = 0.4, p = 0.02). After extubation, IPI values decreased significantly, achieving a minimum by 18 h. The IPI value ≤9 at 6 h after extubation was a predictor of complicated early postoperative period (AUC = 0.71; p = 0.04) observed in 13 patients. In off-pump coronary surgery, the IPI decreases significantly after tracheal extubation and may predict postoperative complications.
Code of Federal Regulations, 2010 CFR
2010-04-01
... that have been in use since 1970, how they changed the evaluation of the applicable impairment and the... should not have been made (e.g., the evidence in your file, such as pulmonary function study values, was... limitations (including any lack of facility with the English language) which you may have had at the time. (2...
Choi, Grace G; Han, Yuchi; Weston, Brian; Ciftci, Esra; Werner, Thomas J; Torigian, Drew; Salavati, Ali; Alavi, Abass
2015-01-01
The aim of this study was to evaluate fluorine-18 fluorodeoxyglucose (18F-FDG) uptake in the right ventricle (RV) of patients with chronic obstructive pulmonary disease (COPD) and to characterize the variability of 18F-FDG uptake in the RV at different time points following radiotracer administration using PET/computerized tomography (CT). Impaired RV systolic function, RV hypertrophy, and RV dilation are associated with increases in mean pulmonary arterial pressure in patients with COPD. Metabolic changes in the RV using 18F-FDG-PET images 2 and 3 h after tracer injection have not yet been investigated. Twenty-five patients with clinical suspicion of lung cancer underwent 18F-FDG-PET/CT imaging at 1, 2, and 3 h after tracer injection. Standardized uptake values (SUVs) and volumes of RV were recorded from transaxial sections to quantify the metabolic activity. The SUV of RV was higher in patients with COPD stages 1-3 as compared with that in patients with COPD stage 0. RV SUV was inversely correlated with FEV1/FVC pack-years of smoking at 1 h after 18F-FDG injection. In the majority of patients, 18F-FDG activity in RV decreased over time. There was no significant difference in the RV myocardial free wall and chamber volume on the basis of COPD status. The severity of lung obstruction and pack-years of smoking correlate with the level of 18F-FDG uptake in the RV myocardium, suggesting that there may be metabolic changes in the RV associated with lung obstruction that can be detected noninvasively using 18F-FDG-PET/CT. Multiple time-point images of the RV did not yield any additional value in this study.
Haji, Darsim L; Ali, Mohamed M; Royse, Alistair; Canty, David J; Clarke, Sandy; Royse, Colin F
2014-10-01
Left atrial pressure and its surrogate, pulmonary capillary wedge pressure (PCWP), are important for determining diastolic function. The role of transthoracic echocardiography (TTE) in assessing diastolic function is well established in awake subjects. The objective was to assess the accuracy of predicting PCWP by TTE and transesophageal echocardiography (TEE) during coronary artery surgery. In 27 adult patients undergoing on-pump coronary artery surgery, simultaneous echocardiographic and hemodynamic measurements were obtained immediately before anesthesia (TTE), after anesthesia and mechanical ventilation (TTE and TEE), during conduit harvest (TEE), and after separation from cardiopulmonary bypass (TEE). Twenty patients had an ejection fraction (EF) of 0.5 or greater. With the exception of E/e' and S/D ratios, echocardiographic values changed over the echocardiographic studies. In patients with low EF, E velocity, deceleration time, pulmonary vein D, S/D, and E/e' ratios correlated well with PCWP before anesthesia. After induction of anesthesia using TTE or TEE, correlations were poor. In normal EF patients, correlations were poor for both TEE and TTE at all five stages. The sensitivity and specificity of echocardiographic values were not high enough to predict raised PCWP except for a fixed curve pattern of interatrial septum (area under the curve 0.89 for PCWP ≥ 17, and 0.98 for ≥ 18 mmHg) and S/D less than 1 (area under the curve 0.74 for PCWP ≥ 17, and 0.78 for ≥ 18 mmHg). Doppler assessment of PCWP was neither sensitive nor specific enough to be clinically useful in anesthetized patients with mechanical ventilation. The fixed curve pattern of the interatrial septum was the best predictor of raised PCWP.
Bak, So Hyeon; Kim, Soohyun; Hong, Yoonki; Heo, Jeongwon; Lim, Myoung-Nam; Kim, Woo Jin
2018-01-01
Background Few studies have investigated the quantitative computed tomography (CT) features associated with the severity of bronchiectasis in COPD patients. The purpose of this study was to identify the quantitative CT features and clinical values to determine the extent of bronchiectasis in moderate-to-severe COPD patients. Methods A total of 127 moderate-to-severe COPD patients were selected from the cohort of COPD in Dusty Areas (CODA). The study subjects were classified into three groups according to the extent of bronchiectasis on CT: no bronchiectasis, mild bronchiectasis, and moderate-to-severe bronchiectasis. The three groups were compared with respect to demographic data, symptoms, medical history, serum inflammatory markers, pulmonary function, and quantitative CT values. Results Among 127 moderate-to-severe COPD subjects, 73 patients (57.5%) were detected to have bronchiectasis, 51 patients (40.2%) to have mild bronchiectasis, and 22 patients (17.3%) to have moderate-to-severe bronchiectasis. Compared with COPD patients without bronchiectasis, those with bronchiectasis were older and had higher frequency of prior tuberculosis, lower prevalence of bronchodilator reversibility (BDR), and more severe air trapping (P < 0.05). Moderate-to-severe bronchiectasis patients had lower body mass index (BMI), higher frequency of prior tuberculosis, lower prevalence of BDR, worse pulmonary function, and more severe air trapping (P < 0.05) than those in the mild bronchiectasis group. Conclusion Moderate-to-severe bronchiectasis was associated with a history of pulmonary tuberculosis, lower BMI, severe airflow obstruction, and lower BDR in moderate-to-severe COPD patients. Quantitative analysis of CT showed that severe air trapping was associated with the extent of bronchiectasis in these patients. PMID:29750028
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goren, A.I.; Hellman, S.; Brenner, S.
During spring 1984, 2,334 second and 2,000 fifth-grade schoolchildren living in three Haifa Bay areas on the eastern Mediterranean coast with different levels of air pollution were studied. The parents of these children filled out American Thoracic Society and National Heart and Lung Institute health questionnaires, and the children performed the following pulmonary function tests (PFT): FVC, FEV{sub 1}, FEV{sub 1}/FEV, PEF, FEF{sub 50}, and FEF{sub 75}. A trend of higher prevalence of most reported respiratory symptoms was found for schoolchildren growing up in the medium and high pollution areas as compared with the low pollution area. Part of themore » reported respiratory diseases were significantly more common among children from the high pollution area. Models fitted for the respiratory conditions that differed significantly among the three areas of residence also included background variables that could be responsible for these differences. Relative risk values, which were calculated from the logistic models, were in the range of 1.38 for sputum with cold and 1.81 for sputum without cold for children from the high pollution area as compared with 1.00 for children from the low pollution area. All the measured values of PFT were within the normal range. There was no consistent trend of reduced pulmonary function that characterized any residential area.« less
Smith, Kelly J; Elidemir, Okan; Dishop, Megan K; Eldin, Karen W; Tatevian, Nina; Moore, Robert H
2006-09-01
Here we present the unusual case of an adolescent with cystic fibrosis presenting with declining pulmonary function and diffuse micronodular pulmonary disease. This case illustrates the radiographic and pathologic findings associated with the intravenous injection and pulmonary arterial embolization of insoluble pharmaceutical-tablet constituents. The number of first-time users reporting nonmedical use of prescription pain relievers is increasing dramatically, especially in adolescents. Recognition of both the diagnostic imaging features and histologic features on lung biopsy are critical steps for early diagnosis, intervention, and potential prevention of sudden death in these at-risk patients.
Usefulness of the 6-minute walk test as a screening test for pulmonary arterial enlargement in COPD
Oki, Yutaro; Kaneko, Masahiro; Fujimoto, Yukari; Sakai, Hideki; Misu, Shogo; Mitani, Yuji; Yamaguchi, Takumi; Yasuda, Hisafumi; Ishikawa, Akira
2016-01-01
Purpose Pulmonary hypertension and exercise-induced oxygen desaturation (EID) influence acute exacerbation of COPD. Computed tomography (CT)-detected pulmonary artery (PA) enlargement is independently associated with acute COPD exacerbations. Associations between PA to aorta (PA:A) ratio and EID in patients with COPD have not been reported. We hypothesized that the PA:A ratio correlated with EID and that results of the 6-minute walk test (6MWT) would be useful for predicting the risk associated with PA:A >1. Patients and methods We retrospectively measured lung function, 6MWT, emphysema area, and PA enlargement on CT in 64 patients with COPD. The patients were classified into groups with PA:A ≤1 and >1. Receiver-operating characteristic curves were used to determine the threshold values with the best cutoff points to predict patients with PA:A >1. Results The PA:A >1 group had lower forced expiratory volume in 1 second (FEV1), forced vital capacity (FVC), FEV1:FVC ratio, diffusion capacity of lung carbon monoxide, 6MW distance, and baseline peripheral oxygen saturation (SpO2), lowest SpO2, highest modified Borg scale results, percentage low-attenuation area, and history of acute COPD exacerbations ≤1 year, and worse BODE (Body mass index, airflow Obstruction, Dyspnea, and Exercise) index results (P<0.05). Predicted PA:A >1 was determined for SpO2 during 6MWT (best cutoff point 89%, area under the curve 0.94, 95% confidence interval 0.88–1). SpO2 <90% during 6MWT showed a sensitivity of 93.1, specificity of 94.3, positive predictive value of 93.1, negative predictive value of 94.3, positive likelihood ratio of 16.2, and negative likelihood ratio of 0.07. Conclusion Lowest SpO2 during 6MWT may predict CT-measured PA:A, and lowest SpO2 <89% during 6MWT is excellent for detecting pulmonary hypertension in COPD. PMID:27920514
Impact of Net Atrioventricular Compliance on Clinical Outcome in Mitral Stenosis
Nunes, Maria Carmo P.; Hung, Judy; Barbosa, Marcia M.; Esteves, William A.; Carvalho, Vinicius T.; Lodi-Junqueira, Lucas; Fonseca Neto, Cirilo P.; Tan, Timothy C.; Levine, Robert A.
2014-01-01
Background Net atrioventricular compliance (Cn) has been reported to be an important determinant of pulmonary hypertension in mitral stenosis (MS). We hypothesized that, as Cn reflects hemodynamic consequences of MS, it may be useful in assessing prognosis. To date, limited data with an assumed Cn cutoff have indicated the need for larger prospective studies. This prospective study was designed to determine the impact of Cn on clinical outcome and its contribution to pulmonary pressure in MS. In addition, we aimed to identify a cutoff value of Cn for outcome prediction in this setting. Methods and Results A total of 128 patients with rheumatic MS without other significant valve disease were prospectively enrolled. Comprehensive echocardiography was performed and Doppler-derived Cn estimated using a previously validated equation. The endpoint was either mitral valve intervention or death. Cn was an important predictor of pulmonary pressure, regardless of classic measures of MS severity. During a median follow-up of 22 months, the endpoint was reached in 45 patients (35%). Baseline Cn predicted outcome, adding prognostic information beyond that provided by mitral valve area and functional status. Cn ≤ 4 mL/mmHg best predicted unfavorable outcome in derivation and validation sets. A subgroup analysis including only initially asymptomatic patients with moderate to severe MS without initial indication for intervention (40.6 % of total) demonstrated that baseline Cn predicted subsequent adverse outcome even after adjusting for classic measures of hemodynamic MS severity (hazard ratio [HR] 0.33, 95% confidence interval [CI] 0.14–0.79, p = 0.013). Conclusions Cn contributes to pulmonary hypertension beyond of stenosis severity itself. In a wide spectrum of MS severity, Cn is a powerful predictor of adverse outcome, adding prognostic value to clinical data and mitral valve area. Importantly, baseline Cn predicts a progressive course with subsequent need for intervention in initially asymptomatic patients. Cn assessment therefore has potential value for clinical risk stratification and monitoring in MS patients. PMID:24097419
Anand, R.
2016-01-01
Objective. To evaluate the effects of diaphragmatic breathing exercises and flow and volume-oriented incentive spirometry on pulmonary function and diaphragm excursion in patients undergoing laparoscopic abdominal surgery. Methodology. We selected 260 patients posted for laparoscopic abdominal surgery and they were block randomization as follows: 65 patients performed diaphragmatic breathing exercises, 65 patients performed flow incentive spirometry, 65 patients performed volume incentive spirometry, and 65 patients participated as a control group. All of them underwent evaluation of pulmonary function with measurement of Forced Vital Capacity (FVC), Forced Expiratory Volume in the first second (FEV1), Peak Expiratory Flow Rate (PEFR), and diaphragm excursion measurement by ultrasonography before the operation and on the first and second postoperative days. With the level of significance set at p < 0.05. Results. Pulmonary function and diaphragm excursion showed a significant decrease on the first postoperative day in all four groups (p < 0.001) but was evident more in the control group than in the experimental groups. On the second postoperative day pulmonary function (Forced Vital Capacity) and diaphragm excursion were found to be better preserved in volume incentive spirometry and diaphragmatic breathing exercise group than in the flow incentive spirometry group and the control group. Pulmonary function (Forced Vital Capacity) and diaphragm excursion showed statistically significant differences between volume incentive spirometry and diaphragmatic breathing exercise group (p < 0.05) as compared to that flow incentive spirometry group and the control group. Conclusion. Volume incentive spirometry and diaphragmatic breathing exercise can be recommended as an intervention for all patients pre- and postoperatively, over flow-oriented incentive spirometry for the generation and sustenance of pulmonary function and diaphragm excursion in the management of laparoscopic abdominal surgery. PMID:27525116
Alaparthi, Gopala Krishna; Augustine, Alfred Joseph; Anand, R; Mahale, Ajith
2016-01-01
Objective. To evaluate the effects of diaphragmatic breathing exercises and flow and volume-oriented incentive spirometry on pulmonary function and diaphragm excursion in patients undergoing laparoscopic abdominal surgery. Methodology. We selected 260 patients posted for laparoscopic abdominal surgery and they were block randomization as follows: 65 patients performed diaphragmatic breathing exercises, 65 patients performed flow incentive spirometry, 65 patients performed volume incentive spirometry, and 65 patients participated as a control group. All of them underwent evaluation of pulmonary function with measurement of Forced Vital Capacity (FVC), Forced Expiratory Volume in the first second (FEV1), Peak Expiratory Flow Rate (PEFR), and diaphragm excursion measurement by ultrasonography before the operation and on the first and second postoperative days. With the level of significance set at p < 0.05. Results. Pulmonary function and diaphragm excursion showed a significant decrease on the first postoperative day in all four groups (p < 0.001) but was evident more in the control group than in the experimental groups. On the second postoperative day pulmonary function (Forced Vital Capacity) and diaphragm excursion were found to be better preserved in volume incentive spirometry and diaphragmatic breathing exercise group than in the flow incentive spirometry group and the control group. Pulmonary function (Forced Vital Capacity) and diaphragm excursion showed statistically significant differences between volume incentive spirometry and diaphragmatic breathing exercise group (p < 0.05) as compared to that flow incentive spirometry group and the control group. Conclusion. Volume incentive spirometry and diaphragmatic breathing exercise can be recommended as an intervention for all patients pre- and postoperatively, over flow-oriented incentive spirometry for the generation and sustenance of pulmonary function and diaphragm excursion in the management of laparoscopic abdominal surgery.
Inapparent pulmonary vascular disease in an ex-heroin user
DOE Office of Scientific and Technical Information (OSTI.GOV)
Antonelli Incalzi, R.; Ludovico Maini, C.; Giuliano Bonetti, M.
1986-04-01
A severe pulmonary vascular derangement, usually reported in drug addicts, was diagnosed in a 28-year-old asymptomatic ex-heroin user by means of fortuitously performed pulmonary perfusion imaging. Neither physical findings nor pulmonary function tests, aroused suspicion of the diagnosis. A search for asymptomatic pulmonary vascular disease probably should be undertaken in drug addicts.
Liu, Jia-Ming; Shen, Jian-Xiong; Zhang, Jian-Guo; Zhao, Hong; Li, Shu-Gang; Zhao, Yu; Qiu, Giu-Xing
2012-01-01
It has been stated that preoperative pulmonary function tests are essential to assess the surgical risk in patients with scoliosis. Arterial blood gas tests have also been used to evaluate pulmonary function before scoliotic surgery. However, few studies have been reported. The aim of this study was to investigate the roles of preoperative arterial blood gas tests in the surgical treatment of scoliosis with moderate or severe pulmonary dysfunction. This study involved scoliotic patients with moderate or severe pulmonary dysfunction (forced vital capacity < 60%) who underwent surgical treatment between January 2002 and April 2010. A total of 73 scoliotic patients (23 males and 50 females) with moderate or severe pulmonary dysfunction were included. The average age of the patients was 16.53 years (ranged 10 - 44). The demographic distribution, medical records, and radiographs of all patients were collected. All patients received arterial blood gas tests and pulmonary function tests before surgery. The arterial blood gas tests included five parameters: partial pressure of arterial oxygen, partial pressure of arterial carbon dioxide, alveolar-arterial oxygen tension gradient, pH, and standard bases excess. The pulmonary function tests included three parameters: forced expiratory volume in 1 second ratio, forced vital capacity ratio, and peak expiratory flow ratio. All five parameters of the arterial blood gas tests were compared between the two groups with or without postoperative pulmonary complications by variance analysis. Similarly, all three parameters of the pulmonary function tests were compared. The average coronal Cobb angle before surgery was 97.42° (range, 50° - 180°). A total of 15 (20.5%) patients had postoperative pulmonary complications, including hypoxemia in 5 cases (33.3%), increased requirement for postoperative ventilatory support in 4 (26.7%), pneumonia in 2 (13.3%), atelectasis in 2 (13.3%), pneumothorax in 1 (6.7%), and hydrothorax in 1 (6.7%). No significant differences in demographic characteristics or perioperative factors (P > 0.05) existed between the two groups with or without postoperative pulmonary complications. According to the variance analysis, there were no statistically significant differences in any parameter of the arterial blood gas tests between the two groups. No significant correlation between the results of the preoperative arterial blood gas tests and postoperative pulmonary complications existed in scoliotic patients with moderate or severe pulmonary dysfunction. However, the postoperative complications tended to increase with the decrease of partial pressure of arterial oxygen in the arterial blood gas tests.
The frequency of pulmonary hypertension in patients with juvenile scleroderma.
Adrovic, Amra; Oztunc, Funda; Barut, Kenan; Koka, Aida; Gojak, Refet; Sahin, Sezgin; Demir, Tuncalp; Kasapcopur, Ozgur
2015-08-22
Juvenile scleroderma (JS) represents a rarely seen group of connective tissue diseases with multiple organ involvement. Cardiac involvement in JSS is well known and, although rare in children, it may be an important cause of mortality and morbidity. Therefore, an early determination of cardio-vascular and pulmonary involvement is of the most relevance to reduce the mortality in patients with juvenile scleroderma. The aim of the study was to explore the non-invasive methods (Doppler echocardiography, pulmonary function tests), Forced vital capacity (FVC) and Carbon monoxide diffusion capacity (DLCO) in the assessment of the cardiopulmonary involvement in patients with JS. The assessment of pulmonary arterial pressure (PAP) and risk factors for pulmonary arterial hypertension (PAH) were made by the measurement of maximum tricuspid insufficiency (TI), end-diastolic pulmonary insufficiency (PI), ratio of acceleration time (AT) to ejection time (ET) (AT/ET), right atrial pressure (RAP) and contraction of vena cava inferior during inspiration. Thirty-five patients with confirmed JS were included in the study. The mean age of onset of the disease was 9.57 years (median 10 years, range 2-18 years). The mean disease duration and follow-up time was 2 years (median 1 year, range 0.5-8 years) and 3.57 years (median 2 years, range 0.5-14.5 years), respectively.The values of all the analyzed parameters including TI, PI, AT/ET, PAP, FVC and DLCO were found to be within normal ranges in all the patients tested, confirming an uncommonness of cardiopulmonary involvement in patients with juvenile scleroderma.
Huang, Yu-Sen; Hsu, Hsao-Hsun; Chen, Jo-Yu; Tai, Mei-Hwa; Jaw, Fu-Shan; Chang, Yeun-Chung
2014-01-01
This study strived to evaluate the relationship between degree of pulmonary emphysema and cardiac ventricular function in chronic obstructive pulmonary disease (COPD) patients with pulmonary hypertension (PH) using electrocardiographic-gated multidetector computed tomography (CT). Lung transplantation candidates with the diagnosis of COPD and PH were chosen for the study population, and a total of 15 patients were included. The extent of emphysema is defined as the percentage of voxels below -910 Hounsfield units in the lung windows in whole lung CT without intravenous contrast. Heart function parameters were measured by electrocardiographic-gated CT angiography. Linear regression analysis was conducted to examine the associations between percent emphysema and heart function indicators. Significant correlations were found between percent emphysema and right ventricular (RV) measurements, including RV end-diastolic volume (R(2) = 0.340, p = 0.023), RV stroke volume (R(2) = 0.406, p = 0.011), and RV cardiac output (R(2) = 0.382, p = 0.014); the correlations between percent emphysema and left ventricular function indicators were not observed. The study revealed that percent emphysema is correlated with RV dysfunction among COPD patients with PH. Based on our findings, percent emphysema can be considered for use as an indicator to predict the severity of right ventricular dysfunction among COPD patients.
Abolmaali, Nasreddin; Koch, Arne; Götzelt, Knut; Hahn, Gabriele; Fitze, Guido; Vogelberg, Christian
2010-07-01
To compare MRI-based functional pulmonary and cardiac measurements in the long-term follow-up of children operated on for left-sided congenital diaphragmatic hernia (CDH) with age- and body size-matched healthy controls. Twelve children who received immediate postnatal surgery for closure of isolated left-sided CDH were included and received basic medical examinations, pulmonary function testing and echocardiography. MRI included measurement of lung volume, ventricular function assessment and velocity-encoded imaging of the pulmonary arteries and was compared with the data for 12 healthy children matched for age and body size. While patients' clinical test results were not suspicious, comparison between the MRI data for patients and those for healthy controls revealed significant differences. In patients, the volumes of the left lungs were increased and the tidal volume was larger on the right side. While the stroke volumes of both ventricles were reduced, heart rate and ejection fraction were increased. Flow, acceleration time and cross-sectional area of the left pulmonary artery were reduced. Functional MRI detected pulmonary and cardiac findings in the late follow-up of CDH children which may be missed by standard clinical methods and might be relevant for decisions regarding late outcome and treatment.
Hassel, Erlend; Berre, Anne Marie; Skjulsvik, Anne Jarstein; Steinshamn, Sigurd
2014-09-28
Right ventricular dysfunction in COPD is common, even in the absence of pulmonary hypertension. The aim of the present study was to examine the effects of high intensity interval training (HIIT) on right ventricular (RV) function, as well as pulmonary blood vessel remodeling in a mouse model of COPD. 42 female A/JOlaHsd mice were randomized to exposure to either cigarette smoke or air for 6 hours/day, 5 days/week for 14 weeks. Mice from both groups were further randomized to sedentariness or HIIT for 4 weeks. Cardiac function was evaluated by echocardiography and muscularization of pulmonary vessel walls by immunohistochemistry. Smoke exposure induced RV systolic dysfunction demonstrated by reduced tricuspid annular plane systolic excursion. HIIT in smoke-exposed mice reversed RV dysfunction. There were no significant effects on the left ventricle of neither smoke exposure nor HIIT. Muscularization of the pulmonary vessels was reduced after exercise intervention, but no significant effects on muscularization were observed from smoke exposure. RV function was reduced in mice exposed to cigarette smoke. No Increase in pulmonary vessel muscularization was observed in these mice, implying that other mechanisms caused the RV dysfunction. HIIT attenuated the RV dysfunction in the smoke exposed mice. Reduced muscularization of the pulmonary vessels due to HIIT suggests that exercise training not only affects the heart muscle, but also has important effects on the pulmonary vasculature.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krzyzanowski, M.; Sherrill, D.L.; Paoletti, P.
The data from consecutive surveys of the Tucson Epidemiologic Study (1981-1988) were used to evaluate the relationship in cigarette smokers of respiratory symptoms and pulmonary function to tar, nicotine, and carbon monoxide (CO) yields of the cigarette. There were 690 subjects who reported smoking regularly in at least one survey, over age 15. After adjustment for intensity and duration of smoking and for depth of inhalation, the risk of chronic phlegm, cough, and dyspnea were not related to the tar and nicotine yields. In 414 subjects with pulmonary function tested in at least one of the three surveys the spirometricmore » indices used were significantly related to the daily dose of tar, nicotine, and CO (product of the cigarette yield and daily number of cigarettes smoked). The effects were more pronounced for past than for current doses. However, the differentiation of pulmonary function due to various yields of cigarettes was small in comparison to the difference in pulmonary function between smokers and nonsmokers.« less
20 CFR 410.426 - Determining total disability: Age, education, and work experience criteria.
Code of Federal Regulations, 2010 CFR
2010-04-01
... capacity (MBC), and 1-second forced expiratory volume (FEV1), are equal to or less than the values... a chronic respiratory or pulmonary impairment which is medically the equivalent of the values...)) establishes that the miner has (or had) a chronic respiratory or pulmonary impairment, the severity of which...
Vieira, Ana Karine; Alvim, Cristina Gonçalves; Carneiro, Maria Cristina Marquez; Ibiapina, Cássio da Cunha
2016-01-01
To evaluate pulmonary function and functional capacity in children and adolescents with sickle cell disease. This was a cross-sectional study involving 70 children and adolescents (8-15 years of age) with sickle cell disease who underwent pulmonary function tests (spirometry) and functional capacity testing (six-minute walk test). The results of the pulmonary function tests were compared with variables related to the severity of sickle cell disease and history of asthma and of acute chest syndrome. Of the 64 patients who underwent spirometry, 15 (23.4%) showed abnormal results: restrictive lung disease, in 8 (12.5%); and obstructive lung disease, in 7 (10.9%). Of the 69 patients who underwent the six-minute walk test, 18 (26.1%) showed abnormal results regarding the six-minute walk distance as a percentage of the predicted value for age, and there was a ≥ 3% decrease in SpO2 in 36 patients (52.2%). Abnormal pulmonary function was not significantly associated with any of the other variables studied, except for hypoxemia and restrictive lung disease. In this sample of children and adolescents with sickle cell disease, there was a significant prevalence of abnormal pulmonary function. The high prevalence of respiratory disorders suggests the need for a closer look at the lung function of this population, in childhood and thereafter. Avaliar a função pulmonar e a capacidade funcional em crianças e adolescentes com doença falciforme. Estudo transversal com 70 crianças e adolescentes com doença falciforme (8-15 anos), submetidos a testes de função respiratória (espirometria) e de capacidade funcional (teste de caminhada de seis minutos). Os resultados da avaliação da função pulmonar foram comparados com variáveis relacionadas à gravidade da doença falciforme e à presença de história de asma e de síndrome torácica aguda. Dos 64 pacientes submetidos à espirometria, 15 (23,4%) apresentaram resultados alterados: distúrbio ventilatório restritivo, em 8; (12,5%) e distúrbio respiratório obstrutivo, em 7 (10,9%). Dos 69 pacientes submetidos ao teste de caminhada de seis minutos, 18 (26,1%) apresentaram resultados alterados na distância em % do previsto para a idade, e houve uma queda ≥ 3% na SpO2 em 36 (52,2%) dos pacientes. Não houve associações significativas entre função pulmonar alterada e as outras variáveis analisadas, exceto para hipoxemia e distúrbio ventilatório restritivo. Observou-se uma significativa prevalência de alterações na função pulmonar nesta amostra de crianças e adolescentes com doença falciforme. A elevada prevalência de distúrbios ventilatórios sugere a necessidade de um olhar mais atento à função pulmonar desde a infância nessa população.
The Changes of Pulmonary Function in COPD During Four-Year Period
Cukic, Vesna; Lovre, Vladimir; Ustamujic, Aida
2013-01-01
Conflict of interest: none declared. Introduction COPD (chronic obstructive pulmonary disease) is characterized by airflow limitation that is not fully reversible. OBJECTIVE: to show the changes of pulmonary function in COPD during the 4 -year evolution of illness. Material and Methods The research was done on patients suffering from COPD treated at the Clinic “Podhrastovi” during 2006 and 2007. The tested parameters were examined from the date of receiving patient with COPD to hospital treatment in 2006 and 2007 and then followed prospectively until 2010 or 2011 (the follow-up period was 4 years). There were total 199 treated patients who were chosen at random and regularly attended the control examinations. The study was conducted on adult patients of both sexes, different age group. In each patient the duration of illness was recorded so is sex, age, data of smoking habits, information about the regularity of taking bronchodilator therapy during remissions of disease, about the treatment of disease exacerbations, results of pulmonary functional tests as follows: FVC (forced vital capacity), FEV1 (forced expiratory volume in one second) and bronchodilator reversibility testing. All these parameters were measured at the beginning and at the end of each hospital treatment on the apparatuses of Clinic “Podhrastovi”. We took in elaboration those data obtained in the beginning of the first hospitalization and at the end of the last hospitalization or at the last control in outpatient department when patient was in stable state. Patients were divided into three groups according to the number of exacerbations per year. Results airflow limitation in COPD is progressive; both FVC and FEV1 shows the statistically significant decrease during follow-up period of 4 years (p values / for both parameters/ =0.05) . But in patients regularly treated in phases of remission and exacerbations of illness the course of illness is slower. The fall of FVC and FEV1 is statistically significantly smaller in those received regular treatment in phases of remissions and exacerbations of illness (p values / for both parameters/ =0.01). The number of patients responding properly to bronchodilators decreased statistically significantly in patients with COPD during follow-up period (p=0.05). Conclusion COPD is characterized with airflow limitation which is progressive in the course of illness, but that course may be made slower using appropriate treatment during remission and exacerbations of diseases. PMID:24082829
2013-01-01
Introduction Pulmonary arterial hypertension (PAH) is a major cause of mortality in systemic sclerosis (SSc). Screening guidelines for PAH recommend multiple investigations, including annual echocardiography, which together have low specificity and may not be cost-effective. We sought to evaluate the predictive accuracy of serum N-terminal pro-brain natriuretic peptide (NT-proBNP) in combination with pulmonary function tests (PFT) (‘proposed’ algorithm) in a screening algorithm for SSc-PAH. Methods We evaluated our proposed algorithm (PFT with NT-proBNP) on 49 consecutive SSc patients with suspected pulmonary hypertension undergoing right heart catherisation (RHC). The predictive accuracy of the proposed algorithm was compared with existing screening recommendations, and is presented as sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). Results Overall, 27 patients were found to have pulmonary hypertension (PH) at RHC, while 22 had no PH. The sensitivity, specificity, PPV and NPV of the proposed algorithm for PAH was 94.1%, 54.5%, 61.5% and 92.3%, respectively; current European Society of Cardiology (ESC)/European Respiratory Society (ERS) guidelines achieved a sensitivity, specificity, PPV and NPV of 94.1%, 31.8%, 51.6% and 87.5%, respectively. In an alternate case scenario analysis, estimating a PAH prevalence of 10%, the proposed algorithm achieved a sensitivity, specificity, PPV and NPV for PAH of 94.1%, 54.5%, 18.7% and 98.8%, respectively. Conclusions The combination of NT-proBNP with PFT is a sensitive, yet simple and non-invasive, screening strategy for SSc-PAH. Patients with a positive screening result can be referred for echocardiography, and further confirmatory testing for PAH. In this way, it may be possible to shift the burden of routine screening away from echocardiography. The findings of this study should be confirmed in larger studies. PMID:24246100
Diagnostic value of sputum adenosine deaminase (ADA) level in pulmonary tuberculosis.
Binesh, Fariba; Jalali, Hadi; Zare, Mohammad Reza; Behravan, Farhad; Tafti, Arefeh Dehghani; Behnaz, Fatemah; Tabatabaee, Mohammad; Shahcheraghi, Seyed Hossein
2016-06-01
Tuberculosis is still a considerable health problem in many countries. Rapid diagnosis of this disease is important, and adenosine deaminase (ADA) has been used as a diagnostic test. The aim of this study was to assess the diagnostic value of ADA in the sputum of patients with pulmonary tuberculosis. The current study included 40 patients with pulmonary tuberculosis (culture positive, smear ±) and 42 patients with non tuberculosis pulmonary diseases (culture negative). ADA was measured on all of the samples. The median value of ADA in non-tuberculosis patients was 2.94 (4.2) U/L and 4.01 (6.54) U/L in tuberculosis patients, but this difference was not statistically significant (p=0.100). The cut-off point of 3.1 U/L had a sensitivity of 61% and a specificity of 53%, the cut-off point of 2.81 U/L had a sensitivity of 64% and a specificity of 50% and the cut-off point of 2.78 U/L had a sensitivity of 65% and a specificity of 48%. The positive predictive values for cut-off points of 3.1, 2.81 and 2.78 U/L were 55.7%, 57.44% and 69.23%, respectively. The negative predictive values for the abovementioned cut-off points were 56.75%, 57.14% and 55.88%, respectively. Our results showed that sputum ADA test is neither specific nor sensitive. Because of its low sensitivity and specificity, determination of sputum ADA for the diagnosis of pulmonary tuberculosis is not recommended.
IDENTIFICATION AND CHARACTERIZATION OF DISEASE USING PULMONARY FUNCTION TESTS
Abstract
Pulmonary function testing is used routinely in human medicine to objectively define functional deficits in individuals with respiratory disease. Despite the fact that respiratory disease is a common problem in veterinary medicine, evaluation of the small animal pa...
Taveira-DaSilva, Angelo M; Julien-Williams, Patricia; Jones, Amanda M; Moss, Joel
2016-07-01
Because pneumothorax is frequent in lymphangioleiomyomatosis, patients have expressed concerns regarding the risk of pneumothorax associated with pulmonary function or exercise testing. Indeed, pneumothorax has been reported in patients with lung disease after both of these tests. The aim of this study was to determine the incidence of pneumothorax in patients with lymphangioleiomyomatosis during admissions to the National Institutes of Health Clinical Research Center between 1995 and 2015. Medical records were reviewed to identify patients who had a pneumothorax during their stay at the National Institutes of Health. A total of 691 patients underwent 4,523 pulmonary function tests and 1,900 exercise tests. Three patients developed pneumothorax after pulmonary function tests and/or exercise tests. The incidence of pneumothorax associated with lung function testing was 0.14 to 0.29 of 100 patients or 0.02 to 0.04 of 100 tests. The incidence of pneumothorax in patients undergoing exercise testing was 0.14 to 0.28 of 100 patients or 0.05 to 0.10 of 100 tests. The risk of pneumothorax associated with pulmonary function or exercise testing in patients with lymphangioleiomyomatosis is low. Published by Elsevier Inc.
INTERPRETATIONS AND LIMITATION OF PULMONARY FUNCTION TESTING IN SMALL LABORATORY ANIMALS
Pulmonary function tests are tools available to the researcher and clinician to evaluate the ability of the lung to perform its essential function of gas exchange. o meet this principal function, the lung needs to operate efficiently with minimal mechanical work as well as provid...
Makino, Ayako; Firth, Amy L.; Yuan, Jason X.-J.
2017-01-01
The pulmonary circulation is a low resistance and low pressure system. Sustained pulmonary vasoconstriction and excessive vascular remodeling often occur under pathophysiological conditions such as in patients with pulmonary hypertension. Pulmonary vasoconstriction is a consequence of smooth muscle contraction. Many factors released from the endothelium contribute to regulating pulmonary vascular tone, while the extracellular matrix in the adventitia is the major determinant of vascular wall compliance. Pulmonary vascular remodeling is characterized by adventitial and medial hypertrophy due to fibroblast and smooth muscle cell proliferation, neointimal proliferation, intimal, and plexiform lesions that obliterate the lumen, muscularization of precapillary arterioles, and in situ thrombosis. A rise in cytosolic free Ca2+ concentration ([Ca2+]cyt) in pulmonary artery smooth muscle cells (PASMC) is a major trigger for pulmonary vasoconstriction, while increased release of mitogenic factors, upregulation (or downregulation) of ion channels and transporters, and abnormalities in intracellular signaling cascades are key to the remodeling of the pulmonary vasculature. Changes in the expression, function, and regulation of ion channels in PASMC and pulmonary arterial endothelial cells play an important role in the regulation of vascular tone and development of vascular remodeling. This article will focus on describing the ion channels and transporters that are involved in the regulation of pulmonary vascular function and structure and illustrating the potential pathogenic role of ion channels and transporters in the development of pulmonary vascular disease. PMID:23733654
Pérez Aceves, Eva; Pérez Cristóbal, Mario; Espinola Reyna, Gerardo A; Ariza Andraca, Raul; Xibille Fridmann, Daniel; Barile Fabris, Leonor A
2013-01-01
Pulmonary hemorrhage (PH) occurs in 2-5% of SLE patients, and is associated with a high mortality rate (79-90%). Diagnostic criteria for this complication include: 1) Pulmonary infiltrates, with at least ¾ of lung tissue involved in a chest x ray, 2) Acute respiratory failure, 3) A decrease of 3g/dL or more in hemoglobin levels. PH might lead to organized pneumonia, collagen deposition, and pulmonary fibrosis which in time might cause changes in pulmonary function tests with either restrictive or obstructive patterns. To evaluate the existence of abnormalities in pulmonary function tests after a PH episode. We included patients with SLE and primary vasculitis that developed PH. During the acute episode, we measured SLEDAI in SLE patients, five factor score in microscopic polyangiitis (MPA) and Birmingham Vasculitis Activity Store (BVAS) in granulomatosis with polyangiitis (GPA) (Wegener). We determined the number of PH events, treatment, and ventilator assistance requirements and correlated its association with abnormal pulmonary function tests. We included 10 patients, 7 with SLE, 2 with MPA and 1 with GPA (Wegener). The mean activity measures were: SLEDAI 20.4 ± 7.5, FFS 2, and BVAS 36. Treatment consisted in methylprednisolone (MPD) in 3 patients, MPD plus cyclophosphamide (CY) in 6 patients, and MPD, CY, IV immunoglobulin, and plasmapheresis in one patient. Five patients required ventilatory support. We found abnormalities in pulmonary function tests in 8 patients, three had an obstructive pattern and five a restrictive pattern; 2 patients did not show any change. We did not find a significant association with any of the studied variables. PH might cause abnormalities in pulmonary function tests and prolonged immunosuppressive treatment could be required. Copyright © 2012 Elsevier España, S.L. All rights reserved.
The effect of pollutional haze on pulmonary function
Liu, Shao-Kun; Cai, Shan; Chen, Yan; Xiao, Bing; Chen, Ping
2016-01-01
Detrimental health effects of atmospheric exposure to ambient particulate matter (PM) have been investigated in numerous studies. Exposure to pollutional haze, the carrier of air pollutants such as PM and nitrogen dioxide (NO2) has been linked to lung and cardiovascular disease, resulting increases in both hospital admissions and mortality. This review focuses on the constituents of pollutional haze and its effects on pulmonary function. The article presents the available information and seeks to correlate pollutional haze and pulmonary function. PMID:26904252
Genome-wide association and large scale follow-up identifies 16 new loci influencing lung function
Artigas, María Soler; Loth, Daan W; Wain, Louise V; Gharib, Sina A; Obeidat, Ma’en; Tang, Wenbo; Zhai, Guangju; Zhao, Jing Hua; Smith, Albert Vernon; Huffman, Jennifer E; Albrecht, Eva; Jackson, Catherine M; Evans, David M; Cadby, Gemma; Fornage, Myriam; Manichaikul, Ani; Lopez, Lorna M; Johnson, Toby; Aldrich, Melinda C; Aspelund, Thor; Barroso, Inês; Campbell, Harry; Cassano, Patricia A; Couper, David J; Eiriksdottir, Gudny; Franceschini, Nora; Garcia, Melissa; Gieger, Christian; Gislason, Gauti Kjartan; Grkovic, Ivica; Hammond, Christopher J; Hancock, Dana B; Harris, Tamara B; Ramasamy, Adaikalavan; Heckbert, Susan R; Heliövaara, Markku; Homuth, Georg; Hysi, Pirro G; James, Alan L; Jankovic, Stipan; Joubert, Bonnie R; Karrasch, Stefan; Klopp, Norman; Koch, Beate; Kritchevsky, Stephen B; Launer, Lenore J; Liu, Yongmei; Loehr, Laura R; Lohman, Kurt; Loos, Ruth JF; Lumley, Thomas; Al Balushi, Khalid A; Ang, Wei Q; Barr, R Graham; Beilby, John; Blakey, John D; Boban, Mladen; Boraska, Vesna; Brisman, Jonas; Britton, John R; Brusselle, Guy G; Cooper, Cyrus; Curjuric, Ivan; Dahgam, Santosh; Deary, Ian J; Ebrahim, Shah; Eijgelsheim, Mark; Francks, Clyde; Gaysina, Darya; Granell, Raquel; Gu, Xiangjun; Hankinson, John L; Hardy, Rebecca; Harris, Sarah E; Henderson, John; Henry, Amanda; Hingorani, Aroon D; Hofman, Albert; Holt, Patrick G; Hui, Jennie; Hunter, Michael L; Imboden, Medea; Jameson, Karen A; Kerr, Shona M; Kolcic, Ivana; Kronenberg, Florian; Liu, Jason Z; Marchini, Jonathan; McKeever, Tricia; Morris, Andrew D; Olin, Anna-Carin; Porteous, David J; Postma, Dirkje S; Rich, Stephen S; Ring, Susan M; Rivadeneira, Fernando; Rochat, Thierry; Sayer, Avan Aihie; Sayers, Ian; Sly, Peter D; Smith, George Davey; Sood, Akshay; Starr, John M; Uitterlinden, André G; Vonk, Judith M; Wannamethee, S Goya; Whincup, Peter H; Wijmenga, Cisca; Williams, O Dale; Wong, Andrew; Mangino, Massimo; Marciante, Kristin D; McArdle, Wendy L; Meibohm, Bernd; Morrison, Alanna C; North, Kari E; Omenaas, Ernst; Palmer, Lyle J; Pietiläinen, Kirsi H; Pin, Isabelle; Polašek, Ozren; Pouta, Anneli; Psaty, Bruce M; Hartikainen, Anna-Liisa; Rantanen, Taina; Ripatti, Samuli; Rotter, Jerome I; Rudan, Igor; Rudnicka, Alicja R; Schulz, Holger; Shin, So-Youn; Spector, Tim D; Surakka, Ida; Vitart, Veronique; Völzke, Henry; Wareham, Nicholas J; Warrington, Nicole M; Wichmann, H-Erich; Wild, Sarah H; Wilk, Jemma B; Wjst, Matthias; Wright, Alan F; Zgaga, Lina; Zemunik, Tatijana; Pennell, Craig E; Nyberg, Fredrik; Kuh, Diana; Holloway, John W; Boezen, H Marike; Lawlor, Debbie A; Morris, Richard W; Probst-Hensch, Nicole; Kaprio, Jaakko; Wilson, James F; Hayward, Caroline; Kähönen, Mika; Heinrich, Joachim; Musk, Arthur W; Jarvis, Deborah L; Gläser, Sven; Järvelin, Marjo-Riitta; Stricker, Bruno H Ch; Elliott, Paul; O’Connor, George T; Strachan, David P; London, Stephanie J; Hall, Ian P; Gudnason, Vilmundur; Tobin, Martin D
2011-01-01
Pulmonary function measures reflect respiratory health and predict mortality, and are used in the diagnosis of chronic obstructive pulmonary disease (COPD). We tested genome-wide association with the forced expiratory volume in 1 second (FEV1) and the ratio of FEV1 to forced vital capacity (FVC) in 48,201 individuals of European ancestry, with follow-up of top associations in up to an additional 46,411 individuals. We identified new regions showing association (combined P<5×10−8) with pulmonary function, in or near MFAP2, TGFB2, HDAC4, RARB, MECOM (EVI1), SPATA9, ARMC2, NCR3, ZKSCAN3, CDC123, C10orf11, LRP1, CCDC38, MMP15, CFDP1, and KCNE2. Identification of these 16 new loci may provide insight into the molecular mechanisms regulating pulmonary function and into molecular targets for future therapy to alleviate reduced lung function. PMID:21946350
Hugues, T; Yaici, K; Latcu, D-G; Rinaldi, J-P; Zarqane, N; Saoudi, N; Gibelin, P
2011-02-01
Echocardiographic criteria of right ventricular dysfunction (RVD) in acute pulmonary embolism (PE) differ among published studies. Assessment of RV systolic function remains difficult because of the RV's complex shape. We aimed to evaluate RV systolic function with TAD in patients (pts) with acute PE. TAD (QLAB, Philips Medical Imaging) was based on a tissue-tracking algorithm that is ultrasound beam angle independent for automated detection of tricuspid annular displacement. Prospective and observational study. All adults' pts who were diagnosed with PE from December 2008 to December 2009 at Princess Grace Hospital, Monaco were eligible for this study after exclusion of history of heart failure. We evaluated 36 consecutive pts with PE (18 male, mean age 62.7 years), which underwent echocardiography, plasma BNP titration during the first day after admission, and a second echocardiography obtained within 48 hours before discharge. TAD value were significantly lower in pts with abnormal RV function by echocardiogram (15.9 ± 0.3 vs. 12.7 ± 0.2 ; P = 0.026). Pts with a normal BNP (<80 pg/ml) had an elevated TAD (16.4 ± 0.2 vs. 11.2 ± 0.3 mm ; P < 0.0001). At discharge, echocardiographic data were obtained from 33 pts (mean: 8.3 ± 3.5 days). RV end diastolic diameter, RV to LV diameter, pulmonary arterial systolic pressure, mean pulmonic valve acceleration time, RV FAC, Sa and TAD were significantly improved. There was no difference between TAD among pts with echocardiographic RVD at baseline vs. pts without RVD (14.9 ± 3.7 vs. 16.1 ± 2.9 mm ; P = 0.3). Four pts who deteriorated during short-term observation had substantially lower TAD values than those with uncomplicated courses (7.7 ± 0.4mm vs. 14.6 ± 0.2 mm ; P = 0.001). In conclusion, impaired TAD was associated with decreased RV systolic function in pts with acute PE. To identify the clinical meaning of decreased TAD, larger trials with longer follow-up periods are needed. Copyright © 2010 Elsevier Masson SAS. All rights reserved.
Dyer, Karrie; Lanning, Craig; Das, Bibhuti; Lee, Po-Feng; Ivy, D. Dunbar; Valdes-Cruz, Lilliam; Shandas, Robin
2007-01-01
Background We have shown previously that input impedance of the pulmonary vasculature provides a comprehensive characterization of right ventricular afterload by including compliance. However, impedance-based compliance assessment requires invasive measurements. Here, we develop and validate a noninvasive method to measure pulmonary artery (PA) compliance using ultrasound color M-mode (CMM) Doppler tissue imaging (DTI). Methods Dynamic compliance (Cdyn) of the PA was obtained from CMM DTI and continuous wave Doppler measurement of the tricuspid regurgitant velocity. Cdyn was calculated as: [(Ds − Dd)/(Dd × Ps)] × 104; where Ds = systolic diameter, Dd = diastolic diameter, and Ps = systolic pressure. The method was validated both in vitro and in 13 patients in the catheterization laboratory, and then tested on 27 pediatric patients with pulmonary hypertension, with comparison with 10 age-matched control subjects. Cdyn was also measured in an additional 13 patients undergoing reactivity studies. Results Instantaneous diameter measured using CMM DTI agreed well with intravascular ultrasound measurements in the in vitro models. Clinically, Cdyn calculated by CMM DTI agreed with Cdyn calculated using invasive techniques (23.4 ± 16.8 vs 29.1 ± 20.6%/100 mm Hg; P = not significant). Patients with pulmonary hypertension had significantly lower peak wall velocity values and lower Cdyn values than control subjects (P < .01). Cdyn values followed an exponentially decaying relationship with PA pressure, indicating the nonlinear stress–strain behavior of these arteries. Reactivity in Cdyn agreed with reactivity measured using impedance techniques. Conclusion The Cdyn method provides a noninvasive means of assessing PA compliance and should be useful as an additional measure of vascular reactivity subsequent to pulmonary vascular resistance in patients with pulmonary hypertension. PMID:16581479
Dyer, Karrie; Lanning, Craig; Das, Bibhuti; Lee, Po-Feng; Ivy, D Dunbar; Valdes-Cruz, Lilliam; Shandas, Robin
2006-04-01
We have shown previously that input impedance of the pulmonary vasculature provides a comprehensive characterization of right ventricular afterload by including compliance. However, impedance-based compliance assessment requires invasive measurements. Here, we develop and validate a noninvasive method to measure pulmonary artery (PA) compliance using ultrasound color M-mode (CMM) Doppler tissue imaging (DTI). Dynamic compliance (C(dyn)) of the PA was obtained from CMM DTI and continuous wave Doppler measurement of the tricuspid regurgitant velocity. C(dyn) was calculated as: [(D(s) - D(d))/(D(d) x P(s))] x 10(4); where D(s) = systolic diameter, D(d) = diastolic diameter, and P(s) = systolic pressure. The method was validated both in vitro and in 13 patients in the catheterization laboratory, and then tested on 27 pediatric patients with pulmonary hypertension, with comparison with 10 age-matched control subjects. C(dyn) was also measured in an additional 13 patients undergoing reactivity studies. Instantaneous diameter measured using CMM DTI agreed well with intravascular ultrasound measurements in the in vitro models. Clinically, C(dyn) calculated by CMM DTI agreed with C(dyn) calculated using invasive techniques (23.4 +/- 16.8 vs 29.1 +/- 20.6%/100 mm Hg; P = not significant). Patients with pulmonary hypertension had significantly lower peak wall velocity values and lower C(dyn) values than control subjects (P < .01). C(dyn) values followed an exponentially decaying relationship with PA pressure, indicating the nonlinear stress-strain behavior of these arteries. Reactivity in C(dyn) agreed with reactivity measured using impedance techniques. The C(dyn) method provides a noninvasive means of assessing PA compliance and should be useful as an additional measure of vascular reactivity subsequent to pulmonary vascular resistance in patients with pulmonary hypertension.
Sade, Leyla Elif; Kozan, Hatice; Eroglu, Serpil; Pirat, Bahar; Aydinalp, Alp; Sezgin, Atilla; Muderrisoglu, Haldun
2017-02-01
Residual pulmonary hypertension challenges the right ventricular function and worsens the prognosis in heart transplant recipients. The complex geometry of the right ventricle complicates estimation of its function with conventional transthoracic echocardiography. We evaluated right ventricular function in heart transplant recipients with the use of 3-dimensional echocardiography in relation to systolic pulmonary artery pressure. We performed 32 studies in 26 heart transplant patients, with 6 patients having 2 studies at different time points with different pressures and thus included. Right atrial volume, tricuspid annular plane systolic excursion, peak systolic annular velocity, fractional area change, and 2-dimensional speckle tracking longitudinal strain were obtained by 2-dimensional and tissue Doppler imaging. Three-dimensional right ventricular volumes, ejection fraction, and 3-dimensional right ventricular strain were obtained from the 3-dimensional data set by echocardiographers. Systolic pulmonary artery pressure was obtained during right heart catheterization. Overall mean systolic pulmonary artery pressure was 26 ± 7 mm Hg (range, 14-44 mmHg). Three-dimensional end-diastolic (r = 0.75; P < .001) and end-systolic volumes (r = 0.55; P = .001)correlated well with systolic pulmonary artery pressure. Right ventricular ejection fraction and right atrium volume also significantly correlated with systolic pulmonary artery pressure (r = 0.49 and P = .01 for both). However, right ventricular 2- and 3-dimensional strain, tricuspid annular plane systolic excursion, and tricuspid annular velocity did not. The effects of pulmonary hemodynamic burden on right ventricular function are better estimated by a 3-dimensional volume evaluation than with 3-dimensional longitudinal strain and other 2-dimensional and tissue Doppler measurements. These results suggest that the peculiar anatomy of the right ventricle necessitates 3-dimensional volume quantification in heart transplant recipients in relation to residual pulmonary hypertension.
Effects of onboard insecticide use on airline flight attendants.
Kilburn, Kaye H
2004-06-01
Flight attendants (FAs) exposed to insecticide spray in an aircraft were compared with unexposed subjects for neurobehavioral function, pulmonary function, mood states, and symptoms. The 33 symptomatic FAs were self-selected, and 5 had retired for disability. Testing procedures included balance, reaction time, color discrimination, visual fields, grip strength, verbal recall, problem solving, attention and discrimination functions, and long-term memory functions. Measurements were expressed as a percentage of their predicted values (derived from unexposed controls), and the author compared the means of the percentage predicted values by analysis of variance. Symptom frequencies and Profile of Mood States (POMS) scores were assessed. FAs were significantly more impaired than controls with respect to balance with eyes closed, grip strength, and color discrimination. Nearly half had 3 or more abnormal neurobehavioral functions, after adjustment was made for age, sex, and education level. Neither elevated POMS scores nor frequencies of average symptoms correlated with their numbers of abnormal measurements. Occupational exposure to synthetic pyrethrin insecticides on airliners was associated with neurobehavioral impairment and disability retirement.
[MRI methods for pulmonary ventilation and perfusion imaging].
Sommer, G; Bauman, G
2016-02-01
Separate assessment of respiratory mechanics, gas exchange and pulmonary circulation is essential for the diagnosis and therapy of pulmonary diseases. Due to the global character of the information obtained clinical lung function tests are often not sufficiently specific in the differential diagnosis or have a limited sensitivity in the detection of early pathological changes. The standard procedures of pulmonary imaging are computed tomography (CT) for depiction of the morphology as well as perfusion/ventilation scintigraphy and single photon emission computed tomography (SPECT) for functional assessment. Magnetic resonance imaging (MRI) with hyperpolarized gases, O2-enhanced MRI, MRI with fluorinated gases and Fourier decomposition MRI (FD-MRI) are available for assessment of pulmonary ventilation. For assessment of pulmonary perfusion dynamic contrast-enhanced MRI (DCE-MRI), arterial spin labeling (ASL) and FD-MRI can be used. Imaging provides a more precise insight into the pathophysiology of pulmonary function on a regional level. The advantages of MRI are a lack of ionizing radiation, which allows a protective acquisition of dynamic data as well as the high number of available contrasts and therefore accessible lung function parameters. Sufficient clinical data exist only for certain applications of DCE-MRI. For the other techniques, only feasibility studies and case series of different sizes are available. The clinical applicability of hyperpolarized gases is limited for technical reasons. The clinical application of the techniques described, except for DCE-MRI, should be restricted to scientific studies.
Zhang, Jinjin; Xu, Pan; Wang, Youlei; Wang, Meirong; Li, Hongbo; Lin, Shengcui; Mao, Cuiping; Wang, Bingsi; Song, Xiaodong; Lv, Changjun
2015-09-01
Promotion of myofibroblast apoptosis is a potential therapeutic strategy for pulmonary fibrosis. This study investigated the antifibrotic effect of astaxanthin on the promotion of myofibroblast apoptosis based on dynamin-related protein-1 (Drp1)-mediated mitochondrial fission in vivo and in vitro. Results showed that astaxanthin can inhibit lung parenchymal distortion and collagen deposition, as well as promote myofibroblast apoptosis. Astaxanthin demonstrated pro-apoptotic function in myofibroblasts by contributing to mitochondrial fission, thereby leading to apoptosis by increasing the Drp1 expression and enhancing Drp1 translocation into the mitochondria. Two specific siRNAs were used to demonstrate that Drp1 is necessary to promote astaxanthin-induced mitochondrial fission and apoptosis in myofibroblasts. Drp1-associated genes, such as Bcl-2-associated X protein, cytochrome c, tumour suppressor gene p53 and p53-up-regulated modulator of apoptosis, were highly up-regulated in the astaxanthin group compared with those in the sham group. This study revealed that astaxanthin can prevent pulmonary fibrosis by promoting myofibroblast apoptosis through a Drp1-dependent molecular pathway. Furthermore, astaxanthin provides a potential therapeutic value in pulmonary fibrosis treatment. © 2015 The Authors. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.
[Failure of static pulmonary volume measurements in mucoviscidosis].
Haluszka, J; Zebrak, J
1984-01-01
With worsening of bronchial obstruction during the course of cystic fibrosis the functional residual capacity (CRF) measured by plethysmography increases progressively. The difference between values of CRF obtained by plethysmography or by Helium dilution increases even more. The difference between the two methods (for CRF) is supposed to show the volume of "trapped"' gas. A similar outcome, although less marked, is observed after physiotherapy. The extent of pulmonary distention and gas trapping is markedly overestimated by plethysmographic measurements, when one considers the anatomical and radiological anomalies. It was recently suggested that the rise in compliance of the walls of the extra-thoracic airways in the presence of bronchial obstruction may lead to an over-estimation of the pulmonary volumes measured by plethysmography. This may be the case during the course of mucoviscidosis, when repeated infections lead to a destruction of the bronchial walls. However, this anomaly does not explain this rise in CRF after mucolytic treatment and postural drainage. The CRF seems to reflect not only the volume of trapper gas in the lung, but equally the failure to equalize the interior pressures of the obstructed airways. In order to appreciate the effects of respiratory physiotherapy, different methods of measuring pulmonary volumes are necessary but the interpretation of the results take account of the complex meterology.
Jang, Timothy B; Aubin, Chandra; Naunheim, Rosanne; Lewis, Lawrence M; Kaji, Amy H
2012-06-01
It can be difficult to differentiate acute heart failure syndrome (AHFS) from other causes of acute dyspnea, especially when patients present in extremis. The objective of the study was to determine the predictive value of physical examination findings for pulmonary edema and elevated B-type natriuretic peptide (BNP) levels in patients with suspected AHFS. This was a secondary analysis of a previously reported prospective study of jugular vein ultrasonography in patients with suspected AHFS. Charts were reviewed for physical examination findings, which were then compared to pulmonary edema on chest radiography (CXR) read by radiologists blinded to clinical information and BNP levels measured at presentation. The predictive value of every sign and combination of signs for pulmonary edema on CXR or an elevated BNP was poor. Since physical examination findings alone are not predictive of pulmonary edema or an elevated BNP, clinicians should have a low threshold for using CXR or BNP in clinical evaluation. This brief research report suggests that no physical examination finding or constellation of findings can be used to reliably predict pulmonary edema or an elevated BNP in patients with suspected AHFS.
Cardiovascular function in pulmonary emphysema.
Visca, Dina; Aiello, Marina; Chetta, Alfredo
2013-01-01
Chronic obstructive pulmonary disease (COPD) and chronic cardiovascular disease, such as coronary artery disease, congestive heart failure, and cardiac arrhythmias, have a strong influence on each other, and systemic inflammation has been considered as the main linkage between them. On the other hand, airflow limitation may markedly affect lung mechanics in terms of static and dynamic hyperinflation, especially in pulmonary emphysema, and they can in turn influence cardiac performance as well. Skeletal mass depletion, which is a common feature in COPD especially in pulmonary emphysema patients, may have also a role in cardiovascular function of these patients, irrespective of lung damage. We reviewed the emerging evidence that highlights the role of lung mechanics and muscle mass impairment on ventricular volumes, stroke volume, and stroke work at rest and on exercise in the presence of pulmonary emphysema. Patients with emphysema may differ among COPD population even in terms of cardiovascular function.
Wachter, S. Blake; Johnson, Ken; Albert, Robert; Syroid, Noah; Drews, Frank; Westenskow, Dwayne
2006-01-01
Objective Authors developed a picture-graphics display for pulmonary function to present typical respiratory data used in perioperative and intensive care environments. The display utilizes color, shape and emergent alerting to highlight abnormal pulmonary physiology. The display serves as an adjunct to traditional operating room displays and monitors. Design To evaluate the prototype, nineteen clinician volunteers each managed four adverse respiratory events and one normal event using a high-resolution patient simulator which included the new displays (intervention subjects) and traditional displays (control subjects). Between-group comparisons included (i) time to diagnosis and treatment for each adverse respiratory event; (ii) the number of unnecessary treatments during the normal scenario; and (iii) self-reported workload estimates while managing study events. Measurements Two expert anesthesiologists reviewed video-taped transcriptions of the volunteers to determine time to treat and time to diagnosis. Time values were then compared between groups using a Mann-Whitney-U Test. Estimated workload for both groups was assessed using the NASA-TLX and compared between groups using an ANOVA. P-values < 0.05 were considered significant. Results Clinician volunteers detected and treated obstructed endotracheal tubes and intrinsic PEEP problems faster with graphical rather than conventional displays (p < 0.05). During the normal scenario simulation, 3 clinicians using the graphical display, and 5 clinicians using the conventional display gave unnecessary treatments. Clinician-volunteers reported significantly lower subjective workloads using the graphical display for the obstructed endotracheal tube scenario (p < 0.001) and the intrinsic PEEP scenario (p < 0.03). Conclusion Authors conclude that the graphical pulmonary display may serve as a useful adjunct to traditional displays in identifying adverse respiratory events. PMID:16929038
Three-Dimensional Echocardiography-Derived Non-Invasive Right Ventricular Pressure-Volume Analysis.
Huang, Kuan-Chih; Lin, Lian-Yu; Hwang, Juey-Jen; Lin, Lung-Chun
2017-09-01
In patients with pulmonary hypertension, repeated evaluations of right ventricular (RV) function are still required for clinical decision making, but the invasive nature of current pressure-volume analysis makes conducting regular follow-ups in a clinical setting infeasible. We enrolled 12 patients with pulmonary arterial hypertension (PAH) and 10 with pulmonary venous hypertension (PVH) May 2016-October 2016. All patients underwent a clinically indicated right heart catheterization (RHC), from which the yielded right ventricular pressure recordings were conjugated with RV volume by 3-D echocardiography to generate a pressure-volume loop. A continuous-wave Doppler envelope of tricuspid regurgitation was transformed into a pressure gradient recording by the simplified Bernoulli equation, and then a systolic pressure gradient-volume (PG-V) diagram was generated from similar methods. The area enclosed by the pressure-volume loop was calculated to represent semi-invasive right ventricular stroke work (RVSW RHC ). The area between the PG-V diagram and x-axis was calculated to estimate non-invasive RVSW (RVSW echo ). Patients with PAH have higher RV pressure, lower pulmonary arterial wedge pressure and larger RV volume that was contributed by the dilation of RV mid-cavity minor dimension. We found no significant difference of traditional parameters between these two groups, but RVSW values were significantly higher in PAH patients. The RVSW values of these two methods were significantly correlated by the equation RVSW echo = 0.8447 RVSW RHC + 129.38 (R 2 = 0.9151, p < 0.001). The linearity remained satisfactory in both groups. We conclude that a PG-V diagram is a reliable method to estimate RVSW and to depict pathophysiological status. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
2012-01-01
Background Pulsed wave (PW) Doppler echocardiography has become a routine non invasive cardiac diagnostic tool in most species. However, evaluation of intracardiac blood flow requires reference values, which are poorly documented in goats. The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy adult Saanen goats. Using a standardised PW Doppler echocardiographic protocol, 10 healthy adult unsedated female Saanen goats were investigated three times at one day intervals by the same observer. Mitral, tricuspid, aortic and pulmonary flows were measured from a right parasternal view, and mitral and aortic flows were also measured from a left parasternal view. The difference between left and right side measurements and the intra-observer inter-day repeatability were tested and then the reference values of PW Doppler echocardiographic parameters in healthy adult female Saanen goats were established. Results As documented in other species, all caprine PW Doppler parameters demonstrated a poor inter-day repeatability and a moderate variability. Tricuspid and pulmonary flows were best evaluated on the right side whereas mitral and aortic flows were best obtained on the left side, and reference values are reported for healthy adult Saanen goats. Conclusions PW Doppler echocardiography allows the measurement of intracardiac blood flow indices in goats. The reference values establishment will help interpreting these indices of cardiac function in clinical cardiac cases and developing animal models for human cardiology research. PMID:23067875
Hsieh, Meng-Jer; Lee, Wei-Chun; Cho, Hsiu-Ying; Wu, Meng-Fang; Hu, Han-Chung; Kao, Kuo-Chin; Chen, Ning-Hung; Tsai, Ying-Huang; Huang, Chung-Chi
2018-04-20
Acute respiratory distress syndrome (ARDS) due to severe influenza A H1N1 pneumonitis would result in impaired pulmonary functions and health-related quality of life (HRQoL) after hospital discharge. The recovery of pulmonary functions, exercise capacity, and HRQoL in the survivors of ARDS due to 2009 pandemic influenza A H1N1 pneumonitis (H1N1-ARDS) was evaluated in a tertiary teaching hospital in northern Taiwan between May 2010 and June 2011. Data of spirometry, total lung capacity (TLC), diffusing capacity of carbon monoxide (DL CO ), and 6-minute walk distance (6MWD) in the patients survived from H1N1-ARDS were collected 1, 3, and 6 months post-hospital discharge. HRQoL was evaluated with St. George respiratory questionnaire (SGRQ). Nine survivors of H1N1-ARDS in the study period were included. All these patients received 2 months' pulmonary rehabilitation program. Pulmonary functions and exercise capacity included TLC, forced vital capacity (FVC), forced expiratory volume in the first second (FEV 1 ), DL CO , and 6MWD improved from 1 to 3 months post-hospital discharge. Only TLC had further significant improvement from 3 to 6 months. HRQoL represented as the total score of SGRQ had no significant improvement in the first 3 months but improved significantly from 3 to 6 months post-discharge. The impaired pulmonary functions and exercise capacity in the survivors of H1N1-ARDS improved soon at 3 months after hospital discharge. Their quality of life had keeping improved at 6 months even though there was no further improvement of their pulmonary functions and exercise capacity. © 2018 The Authors. Influenza and Other Respiratory Viruses Published by John Wiley & Sons Ltd.
Moullec, G; Ninot, G
2010-02-01
To assess whether a maintenance integrated health care programme is effective in improving functional and emotional dimensions of quality of life in patients with chronic obstructive pulmonary disease (COPD) after a first pulmonary rehabilitation. Prospective controlled trial. Three rehabilitation centres and three patient self-help associations within a health care network in France. Forty patients with moderate to severe COPD. After a first four-week inpatient pulmonary rehabilitation programme, patients took part in a maintenance integrated health care programme or usual care for 12 months. The primary outcomes were the change in functional and emotional dimensions of quality of life measured by the St George's Respiratory Questionnaire (SGRQ), the brief World Health Organization Quality of Life questionnaire (Brief-WHOQOL) and six specific questions using a 10-cm visual analogue scale. Secondary outcomes were change in exercise tolerance measured by six-minute walking test and cycle exercise. At one year, the maintenance intervention (n = 11) produced improvements in functional and emotional dimensions scores of quality of life and exercise tolerance. Patients in the usual aftercare group (n = 16) exhibited maintenance of functional dimension scores of quality of life, but a clinically relevant decline in emotional scores of quality of life and in six-minute walking distance one year after the pulmonary rehabilitation. Patient self-help association seems to be an innovative and efficient organizational structure to support patients with COPD after pulmonary rehabilitation in real-life settings. A distinction between emotional and functional dimensions of quality of life may improve the design and evaluation of integrated health care programmes in patients with COPD.
Evolving Concepts of Pulmonary Hypertension Secondary to Left Heart Disease.
Ramu, Bhavadharini; Thenappan, Thenappan
2016-04-01
Pulmonary hypertension associated with left heart disease is the most common form of pulmonary hypertension. Although its pathophysiology remains incompletely understood, it is now well recognized that the presence of pulmonary hypertension is associated with a worse prognosis. Right ventricular failure has independent and additive prognostic value over pulmonary hypertension for adverse outcomes in left heart disease. Recently, several new terminologies have been introduced to better define and characterize the nature and severity of pulmonary hypertension. Several new treatment options including the use of pulmonary arterial hypertension specific therapies are being considered, but there is lack of evidence. Here, we review the recent advances in this field and summarize the diagnostic and therapeutic modalities of use in the management of pulmonary hypertension associated with left heart disease.
Astorga, Cristian R.; González-Candia, Alejandro; Candia, Alejandro A.; Figueroa, Esteban G.; Cañas, Daniel; Ebensperger, Germán; Reyes, Roberto V.; Llanos, Aníbal J.; Herrera, Emilio A.
2018-01-01
Background: Chronic hypoxia and oxidative stress during gestation lead to pulmonary hypertension of the neonate (PHN), a condition characterized by abnormal pulmonary arterial reactivity and remodeling. Melatonin has strong antioxidant properties and improves pulmonary vascular function. Here, we aimed to study the effects of melatonin on the function and structure of pulmonary arteries from PHN lambs. Methods: Twelve lambs (Ovis aries) gestated and born at highlands (3,600 m) were instrumented with systemic and pulmonary catheters. Six of them were assigned to the control group (CN, oral vehicle) and 6 were treated with melatonin (MN, 1 mg.kg−1.d−1) during 10 days. At the end of treatment, we performed a graded oxygenation protocol to assess cardiopulmonary responses to inspired oxygen variations. Further, we obtained lung and pulmonary trunk samples for histology, molecular biology, and immunohistochemistry determinations. Results: Melatonin reduced the in vivo pulmonary pressor response to oxygenation changes. In addition, melatonin decreased cellular density of the media and diminished the proliferation marker KI67 in resistance vessels and pulmonary trunk (p < 0.05). This was associated with a decreased in the remodeling markers α-actin (CN 1.28 ± 0.18 vs. MN 0.77 ± 0.04, p < 0.05) and smoothelin-B (CN 2.13 ± 0.31 vs. MN 0.88 ± 0.27, p < 0.05). Further, melatonin increased vascular density by 134% and vascular luminal surface by 173% (p < 0.05). Finally, melatonin decreased nitrotyrosine, an oxidative stress marker, in small pulmonary vessels (CN 5.12 ± 0.84 vs. MN 1.14 ± 0.34, p < 0.05). Conclusion: Postnatal administration of melatonin blunts the cardiopulmonary response to hypoxia, reduces the pathological vascular remodeling, and increases angiogenesis in pulmonary hypertensive neonatal lambs.These effects improve the pulmonary vascular structure and function in the neonatal period under chronic hypoxia. PMID:29559926
Macke, Ryan A; Schuchert, Matthew J; Odell, David D; Wilson, David O; Luketich, James D; Landreneau, Rodney J
2015-04-01
A suggested benefit of sublobar resection for stage I non-small cell lung cancer (NSCLC) compared to lobectomy is a relative preservation of pulmonary function. Very little objective data exist, however, supporting this supposition. We sought to evaluate the relative impact of both anatomic segmental and lobar resection on pulmonary function in patients with resected clinical stage I NSCLC. The records of 159 disease-free patients who underwent anatomic segmentectomy (n = 89) and lobectomy (n = 70) for the treatment of stage I NSCLC with pre- and postoperative pulmonary function tests performed between 6 to 36 months after resection were retrospectively reviewed. Changes in forced expiratory volume in one second (FEV1) and diffusion capacity of carbon monoxide (DLCO) were analyzed based upon the number of anatomic pulmonary segments removed: 1-2 segments (n = 77) or 3-5 segments (n = 82). Preoperative pulmonary function was worse in the lesser resection cohort (1-2 segments) compared to the greater resection group (3-5 segments) (FEV1(%predicted): 79% vs. 85%, p = 0.038; DLCO(%predicted): 63% vs. 73%, p = 0.010). A greater decline in FEV1 was noted in patients undergoing resection of 3-5 segments (FEV1 (observed): 0.1 L vs. 0.3 L, p = 0.003; and FEV1 (% predicted): 4.3% vs. 8.2%, p = 0.055). Changes in DLCO followed this same trend (DLCO(observed): 1.3 vs. 2.4 mL/min/mmHg, p = 0.015; and DLCO(% predicted): 3.6% vs. 5.9%, p = 0.280). Parenchymal-sparing resections resulted in better preservation of pulmonary function at a median of one year, suggesting a long-term functional benefit with small anatomic segmental resections (1-2 segments). Prospective studies to evaluate measurable functional changes, as well as quality of life, between segmentectomy and lobectomy with a larger patient cohort appear justified.
Todisco, T; Dottorini, M; Rossi, F; Baldoncini, A; Palumbo, R
1989-01-01
Peripheral airspace epithelial permeability (PAEP) to diethylentriaminopentacetate (DTPA), an index of pulmonary integrity, was measured in 3 groups of subjects for different purposes: (1) to establish vertical regional reference values; (2) to determine the physiological role of acute doubling of total pulmonary blood flow; (3) to quantify the pulmonary epithelial damage in smokers and the possibility of lung protection by an agent stimulating surfactant production. This study broadens previous knowledge of PAEP. First of all, regional reference values are given for young normal nonsmoking subjects and the existence of a vertical gradient of PAEP is confirmed. Furthermore, this study shows that this gradient is independent of the vertical blood flow gradient, since an acute increase of total blood flow in pneumonectomized patients does not modify the regional distribution of PAEP. Finally, it is confirmed that the cigarette smoker's lung is more permeable than the controls and that probably a drug-stimulating surfactant production gives some protection against damage due to chronic smoking.
Lee, Edward Y; Jenkins, Kathy J; Muneeb, Muhammad; Marshall, Audrey C; Tracy, Donald A; Zurakowski, David; Boiselle, Phillip M
2013-08-01
One of the important benefits of using multidetector computed tomography (MDCT) is its capability to generate high-quality two-dimensional (2-D) multiplanar (MPR) and three-dimensional (3-D) images from volumetric and isotropic axial CT data. However, to the best of our knowledge, no results have been published on the potential diagnostic role of multiplanar and 3-D volume-rendered (VR) images in detecting pulmonary vein stenosis, a condition in which MDCT has recently assumed a role as the initial noninvasive imaging modality of choice. The purpose of this study was to compare diagnostic accuracy and interpretation time of axial, multiplanar and 3-D VR images for detection of proximal pulmonary vein stenosis in children, and to assess the potential added diagnostic value of multiplanar and 3-D VR images. We used our hospital information system to identify all consecutive children (< 18 years of age) with proximal pulmonary vein stenosis who had both a thoracic MDCT angiography study and a catheter-based conventional angiography within 2 months from June 2005 to February 2012. Two experienced pediatric radiologists independently reviewed each MDCT study for the presence of proximal pulmonary vein stenosis defined as ≥ 50% of luminal narrowing on axial, multiplanar and 3-D VR images. Final diagnosis was confirmed by angiographic findings. Diagnostic accuracy was compared using the z-test. Confidence level of diagnosis (scale 1-5, 5 = highest), perceived added diagnostic value (scale 1-5, 5 = highest), and interpretation time of multiplanar or 3-D VR images were compared using paired t-tests. Interobserver agreement was measured using the chance-corrected kappa coefficient. The final study population consisted of 28 children (15 boys and 13 girls; mean age: 5.2 months). Diagnostic accuracy based on 116 individual pulmonary veins for detection of proximal pulmonary vein stenosis was 72.4% (84 of 116) for axial MDCT images, 77.5% (90 of 116 cases) for multiplanar MDCT images, and 93% (108 of 116 cases) for 3-D VR images with significantly higher accuracy with 3-D VR compared to axial (z = 4.17, P < 0.001) and multiplanar (z = 3.34, P < 0.001) images. Confidence levels for detection of proximal pulmonary vein stenosis were significantly higher with 3-D VR images (mean level: 4.6) compared to axial MDCT images (mean level: 1.7) and multiplanar MDCT images (mean level: 2.0) (paired t-tests, P < 0.001). Thus, 3-D VR images (mean added diagnostic value: 4.7) were found to provide added diagnostic value for detecting proximal pulmonary vein stenosis (paired t-test, P < 0.001); however, multiplanar MDCT images did not provide added value (paired t-test, P = 0.89). Interpretation time was significantly longer and interobserver agreement was higher when using 3-D VR images than using axial MDCT images or MPR MDCT images for diagnosing proximal pulmonary vein stenosis (paired t-tests, P < 0.001). Use of 3-D VR images in the diagnosis of proximal pulmonary vein stenosis in children significantly increases accuracy, confidence level, added diagnostic value and interobserver agreement. Thus, the routine use of this technique should be encouraged despite its increased interpretation time.
2017-01-04
you have normal pulmonary function? YES NO 6. Have you ever been diagnosed with heart /circulatory disease ? YES NO 7. Do you...total dropout, the Canary system occasionally exhibited long stretches of data with sporadic heart rate signal dropout accompanied by high variance...values as low as 86%. This occurs over a timespan with sporadic heart rate signal dropout and greater mismatch between Canary and Ohmeda HR
Tawhai, M. H.; Clark, A. R.; Donovan, G. M.; Burrowes, K. S.
2011-01-01
Computational models of lung structure and function necessarily span multiple spatial and temporal scales, i.e., dynamic molecular interactions give rise to whole organ function, and the link between these scales cannot be fully understood if only molecular or organ-level function is considered. Here, we review progress in constructing multiscale finite element models of lung structure and function that are aimed at providing a computational framework for bridging the spatial scales from molecular to whole organ. These include structural models of the intact lung, embedded models of the pulmonary airways that couple to model lung tissue, and models of the pulmonary vasculature that account for distinct structural differences at the extra- and intra-acinar levels. Biophysically based functional models for tissue deformation, pulmonary blood flow, and airway bronchoconstriction are also described. The development of these advanced multiscale models has led to a better understanding of complex physiological mechanisms that govern regional lung perfusion and emergent heterogeneity during bronchoconstriction. PMID:22011236
López-Candales, Angel
2014-07-01
Right ventricular (RV) dilatation and systolic dysfunction are known remodeling changes occurring in chronic pulmonary hypertension and are likely the result of increases in pulmonary vascular resistance (PVR). It remains unclear whether PVR affects primarily the main RV chamber (mRVc) or the RV outflow tract (RVOT). Standard echocardiography data were collected from a heterogeneous population of 85 consecutive patients (mean age of 54 ± 12 years and mean pulmonary artery systolic pressure of 56 ± 28 mm Hg) to determine how PVR affected size and function of both RV chambers. Regarding size, PVR correlated more with mRVc end systolic area (r = 0.77; P < 0.0001) than either mRVc end diastolic area (r = 0.58; P < 0.0001) or RVOT systolic length (r = 0.54; P < 0.0001), although it did not correlate with RVOT end diastolic length. In terms of fractional area change, a stronger negative correlation was seen between PVR and mRVc (r = -0.77; P < 0.0001) than with PVR and RVOT (r = -0.69; P < 0.0001). Systolic velocity of the tricuspid annulus was the best parameter in identifying elevated PVR. Based on the echocardiography results, increasing PVR values appear to result in differential RV remodeling with significant mRVc dilation and systolic dysfunction when compared with RVOT. It is important to determine whether the different RV remodeling processes occur in all patients with chronic pulmonary hypertension, regardless of etiology; alter therapeutic response; or determine clinical outcomes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ward, W.F.; Molteni, A.; Ts'ao, C.H.
The purpose of this study was to evaluate the angiotensin converting enzyme (ACE) inhibitor CL242817 as a modifier of radiation-induced pulmonary endothelial dysfunction and pulmonary fibrosis in rats sacrificed 2 months after a single dose of 60Co gamma rays (0-30 Gy) to the right hemithorax. CL242817 was administered in the feed continuously after irradiation at a regimen of 60 mg/kg/day. Pulmonary endothelial function was monitored by lung ACE activity, plasminogen activator (PLA) activity, and prostacyclin (PGI2) and thromboxane (TXA2) production. Pulmonary fibrosis was evaluated by lung hydroxyproline (HP) content. Lung ACE and PLA activities decreased with increasing radiation dose, andmore » cotreatment with CL242817 significantly ameliorated both responses. CL242817 dose-reduction factors (DRF) were 1.3-1.5 for ACE and PLA activity. Lung PGI2 and TXA2 production increased with increasing radiation dose, and CL242817 almost completely prevented both radiation responses. The slope of the radiation dose-response curves in the CL242817-treated rats was essentially zero, precluding calculation of DRF values for PGI2 and TXA2 production. Lung HP content also increased with increasing radiation dose, and CL242817 significantly attenuated this response (DRF = 1.5). These data suggest that the ability of ACE inhibitors to ameliorate radiation-induced pulmonary endothelial dysfunction is not unique to captopril, rather it is a therapeutic action shared by other members of this class of compounds. These data also provide the first evidence that ACE inhibitors exhibit antifibrotic activity in irradiated rat lung.« less
The Mid-Term Changes of Pulmonary Function Tests After Phrenic Nerve Transfer.
Yavari, Masoud; Hassanpour, Seyed Esmail; Khodayari, Mohammad
2016-03-01
In the restoration of elbow flexion, the phrenic nerve has proven to be a good donor, but considering the role of the phrenic nerve in respiratory function, we cannot disregard the potential dangers of this method. In the current study, we reviewed the results of pulmonary function tests (PFT) in four patients who underwent phrenic nerve transfer. We reviewed the results of serial spirometry tests, which were performed before and after phrenic nerve transfer surgery. All patients regained Biceps power to M3 strength or above. None of our patients experienced pulmonary problems or respiratory complaints, but a significant reduction of spirometric parameters occurred after surgery. This study highlights the close link between the role of the phrenic nerve and pulmonary function, such that the use of this nerve as a transfer donor leads to spirometric impairments.
Liu, Yonggang
2015-07-01
To explore the correlation between the severity of patients with rhinitis-nasosinusitis and the bronchial asthma and the pulmonary function. Sixty-four cases of patients with rhinitis-nasosinusitis and 53 cases of patients with chronic sinusitis from June 2012 to September 2013 were randomly selected, and the patients were divided into group of rhinitis-nasosinusitis with nasal polyps and group of chronic sinusitis according to disease species, and analyzed the correlation between the severity of the deseases and the changes of the pulmonary function respectively for the patients of two groups by using Spearman method. The incidence of asthma for patients with different levels of sinusitis and nasal polyps seemed no significant difference (P > 0.05); the incidence of allergic rhinitis also seemed no significant difference (P > 0.05); the incidence of asthma for patients with different lesion range of sinusitis and nasal polyps seemed no significant difference (P > 0.05); the incidence of allergic rhinitis also seemed no significant different (P < 0.05). The conditions of the patients with different levels of sinusitis and nasal polyps were directly related to the reduction of pulmonary function (r = 2.431, P < 0.05); The conditions of the patients with different lesion range of sinusitis were directly related to the reduction of pulmonary function (r = 2.641, P < 0.05). There was some correlation between the severity of patients with rhinitis-nasosinusitis and the bronchial asthma and the condition of pulmonary function of patients.
Lee, Ji Hyun; Hong, A Ram; Kim, Jung Hee; Kim, Kyoung Min; Koo, Bo Kyung; Shin, Chan Soo; Kim, Sang Wan
2018-01-01
Smoking induces bone loss; however, data on the relationship between smoking history and bone mineral density (BMD) are lacking. Age and pulmonary function can affect BMD. We investigated the relationships among pack-years (PYs) of smoking, pulmonary function, and BMD in middle-aged Korean men (50-64 years old). This cross-sectional study used data from the Korean National Health and Nutrition Examination Survey, 2008-2011. All participants underwent BMD measurements using dual energy X-ray absorptiometry and pulmonary function tests using standardized spirometry. In total, 388 never-smokers and 1088 ever-smokers were analyzed. The number of PYs of smoking was negatively correlated with total hip BMD (r = -0.088; P = 0.004) after adjusting for age, height, and weight. Ever-smokers were classified into 3 groups according to PYs of smoking. The highest tertile (n = 482) exhibited significantly lower total hip bone mass than the lowest tertile (n = 214) after adjusting for confounding factors (age, height, weight, forced expiratory volume in 1 s (FEV 1 ), alcohol consumption, physical activity, and vitamin D levels) that could affect bone metabolism (P = 0.003). In conclusion, smoking for >30 PYs was significantly associated with low hip BMD after adjusting for pulmonary function in middle-aged Korean men. Long-term smoking may be a risk factor for bone loss in middle-aged men independent of age, height, weight, and pulmonary function.
[A rare form of obstructive pulmonary disease].
van Loenhout, C J; den Bakker, M A; van Wijsenbeek, M S; Hoek, R A S; van Hal, P Th W
2016-01-01
Lymphangioleiomyomatosis (LAM) is characterised by progressive dyspnoea, spontaneous pneumothorax and cystic pulmonary destruction. The disease may show similarities with emphysema clinically, radiologically and on lung function tests. A 44-year-old woman was referred for lung transplantation because of a 6-year history of dyspnoea and severe obstructive pulmonary function disorder with decreased diffusion capacity. Both her relatively young age and the fact that she had never smoked made us doubt the diagnosis 'COPD'. The pulmonary cysts seen on high-resolution CT (HRCT) suggested LAM. This was confirmed when we revised a pulmonary biopsy that had previously been performed. CT investigation should be carried out in patients with severe obstructive pulmonary disease without a risk profile appropriate for COPD. Diffuse, homogenous cysts on CT scan can indicate LAM, particularly in women. Conflict of interest and financial support: none declared.
Henno, Priscilla; Grassin-Delyle, Stanislas; Belle, Emeline; Brollo, Marion; Naline, Emmanuel; Sage, Edouard; Devillier, Philippe; Israël-Biet, Dominique
2017-05-23
Tobacco-induced pulmonary vascular disease is partly driven by endothelial dysfunction. The Sonic hedgehog (SHH) pathway is involved in vascular physiology. We sought to establish whether the SHH pathway has a role in pulmonary endothelial dysfunction in smokers. The ex vivo endothelium-dependent relaxation of pulmonary artery rings in response to acetylcholine (Ach) was compared in 34 current or ex-smokers and 8 never-smokers. The results were expressed as a percentage of the contraction with phenylephrine. We tested the effects of SHH inhibitors (GANT61 and cyclopamine), an SHH activator (SAG) and recombinant VEGF on the Ach-induced relaxation. The level of VEGF protein in the pulmonary artery ring was measured in an ELISA. SHH pathway gene expression was quantified in reverse transcriptase-quantitative polymerase chain reactions. Ach-induced relaxation was much less intense in smokers than in never-smokers (respectively 24 ± 6% and 50 ± 7% with 10 -4 M Ach; p = 0.028). All SHH pathway genes were expressed in pulmonary artery rings from smokers. SHH inhibition by GANT61 reduced Ach-induced relaxation and VEGF gene expression in the pulmonary artery ring. Recombinant VEGF restored the ring's endothelial function. VEGF gene and protein expression levels in the pulmonary artery rings were positively correlated with the degree of Ach-induced relaxation and negatively correlated with the number of pack-years. SHH pathway genes and proteins are expressed in pulmonary artery rings from smokers, where they modulate endothelial function through VEGF.
Kieran, S M; Cahill, R A; Browne, I; Sheehan, S J; Mehigan, D; Barry, M C
2006-09-01
Concern about the potential detrimental side-effects of beta-blockade on pulmonary function often dissuades against their perioperative use in patients undergoing major arterial surgery (especially in those with chronic obstructive pulmonary disease (COPD)). In this study we aimed to establish prospectively the clinical relevance of these concerns. After ethics committee approval and individual informed consent, the pulmonary function of twenty patients (mean age 68.7 years (range 43-82), 11 males) scheduled to undergo non-emergency major vascular surgery was studied by recording symptoms and spirometry before and after institution of effective beta-blockade. Fifteen patients (75%) had significant smoking histories (mean pack years/patient=50), while 12 (60%) had COPD. All patients tolerated effective beta-blockade satisfactorily without developing either subjective deterioration in symptoms or significant change on spirometry. The mean change in FEV1 following adequate beta-blockade was 0.05+/-0.24 liters (95% CI -0.06 to +1.61), p=0.35, giving a mean percentage change of 3.18%+/-11.66 (95% CI -2.26 to 8.62). Previously held concerns about worsening pulmonary function through the short-term use of beta-blockers should not dissuade their perioperative usage in patients with peripheral vascular disease. Furthermore, the accuracy of pulmonary function tests in preoperative assessment and risk stratification also appears unaffected by this therapy.
Doubková, Martina; Karpíšek, Michal; Mazoch, Jiri; Skřičková, Jana; Doubek, Michael
2016-10-07
Identification of serum and bronchoalveolar lavage fluid (BALF) biomarkers may facilitate diagnosis and prognostication in various lung disorders. Serum and BALF levels of surfactant protein A (SP-A), surfactant protein D (SP-D), Clara cell protein 16 (CC16), S100 protein, trefoil factor 3 (TFF3), and prostatic secretory protein 94 (PSP94) were evaluated in 94 consecutive patients (idiopathic pulmonary fibrosis (IPF; n=18), sarcoidosis (n=25), chronic obstructive pulmonary disease (COPD; n=51)), and in 155 healthy controls. Biomarkers were measured at diagnosis and compared with disease characteristics. Both uniparametric and multiparametric analyses were used. Seven significant correlations were found: 1) BALF PSP94 level correlated with prognosis of sarcoidosis (P=0.035); 2) BALF SP-D level with pulmonary functions in IPF (P=0.032); 3) BALF SP-D and TFF3 with IPF mortality (P=0.049 and 0.017, respectively); 4) serum TFF3 level with COPD mortality (P=0.006,); 5) serum SP-A with pulmonary functions impairment in IPF (P=0.011); 6) serum SP-D level was associated with HRCT interstitial score in IPF (P=0.0346); and 7) serum SP-A was associated with staging of COPD according to spirometry (P<0.001). Moreover, our analysis showed that some biomarker levels differed significantly among the diseases: 1) BALF SP-D level differed between sarcoidosis and IPF; 2) serum SP-A level differed among IPF, sarcoidosis, COPD and was also different from healthy controls; 3) serum S100A6, S100A11 levels differed among IPF, sarcoidosis, COPD from healthy controls 4) serum SP-D, CC16, TFF-3 levels distinguished IPF patients from healthy controls; and 5) serum CC16, TFF3, PSP94 distinguished COPD patients from healthy controls. Our study shows that some of selected biomarkers should have prognostic value in the analysed lung disorders. On the other hand, these biomarkers do not appear to be unequivocally suitable for differential diagnosis of these disorders.
Ventilatory function in rubber processing workers: acute changes over the workshift.
Governa, M; Comai, M; Valentino, M; Antonicelli, L; Rinaldi, F; Pisani, E
1987-02-01
When considering rubber tyre manufacturing from an occupational health viewpoint, three areas may be identified in which exposure to respirable materials are potentially harmful: the processing, curing, and talc areas. A study of the ventilatory function of the entire work force employed in the processing area in a rubber tyre manufacturing plant was undertaken to determine whether an acute reduction in lung function occurs over the course of their working shift (the plant worked a three shift system) and whether a chronic exposure to the occupational airborne contaminants causes permanent changes in lung function. The ventilatory function was measured at the worksite at the beginning and immediately after the end of the workshift. No evidence of chronic obstructive pulmonary disease was found and in most cases no significant decline in FEV1 was observed. Only one of the 79 individuals showed a moderate obstruction, measured by the ratio FEV1/FVC which gave the value of 0.55, with no variation over the shift. For non-smokers, the FVC, FEV1, and FEF25-75% were lower in those exposed for more than five years than in those exposed for five years or less. A similar pattern was also observed in the FVC and FEV1 of the smokers. None of these differences was statistically significant. Within each exposure group the pulmonary function of the smokers was lower than that of the non-smokers, but the only significant difference was found in the values of FEF25-75%. Only one man showed a decline in the FEV1/FVC ratio over the shift, but during each shift, a decrease in all the lung function tests was observed. The decrease was smallest during the first of the three shifts. These results are thought to support the hypothesis that there are acute adverse effects over an eight hour shift. Further investigations are needed to discover whether these acute changes in lung function result from a chemical stimulation or irritant receptors in the airways.
Huang, Ai-Xia; Lu, Li-Wen; Liu, Wen-Juan; Huang, Mao
2016-08-09
BACKGROUND The aim of this study was to investigate the plasma inflammatory cytokine levels and their correlations with pulmonary function in patients with asthma-chronic obstructive pulmonary disease overlap syndrome (ACOS). MATERIAL AND METHODS Between January 2013 and December 2014, a total of 96 patients with asthma, acute exacerbation of chronic obstructive pulmonary disease (AECOPD), or ACOS were enrolled, and 35 healthy people were included as a control group. Fasting plasma interleukin (IL)-4, IL-8, IL-10, and tumor necrosis factor alpha (TNF-α) levels were detected using enzyme-linked immunosorbent assay (ELISA). Correlations between the plasma inflammatory cytokine levels and forced expiratory volume in 1 second (FEV1), FEV1/predicted value ratio (FEV1%pred), and FEV1/forced vital capacity (FVC) were analyzed. RESULTS IL-4 and IL-8 levels showed statistically significant differences among the 3 groups of patients (both P<0.001); IL-4 level was significantly lower, while IL-8 level was significantly higher in the AECOPD group and ACOS group than those in the asthma group (all P<0.05). IL-10 level and TNF-α level were significantly different among the 3 patient groups (both P<0.001). IL-10 level was significantly different between each of the 2 groups (all P<0.001). TNF-α level in the asthma group was higher than in the AECOPD group and ACOS group (both P<0.001). IL-4 and IL-10 were positively and IL-8 and TNF-α were negatively related with FEV1, FEV1%pred, and FEV1/FVC. CONCLUSIONS Plasma levels of inflammatory cytokines IL-4, IL-8, IL-10, and TNF-α are related with severity of airway diseases and could be potential markers for the evaluation of asthma, COPD, and ACOS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suckling, Tara; Smith, Tony; Reed, Warren
2013-06-15
Optimal arterial opacification is crucial in imaging the pulmonary arteries using computed tomography (CT). This poses the challenge of precisely timing data acquisition to coincide with the transit of the contrast bolus through the pulmonary vasculature. The aim of this quality assurance exercise was to investigate if a change in CT pulmonary angiography (CTPA) scanning protocol resulted in improved opacification of the pulmonary arteries. Comparison was made between the smart prep protocol (SPP) and the test bolus protocol (TBP) for opacification in the pulmonary trunk. A total of 160 CTPA examinations (80 using each protocol) performed between January 2010 andmore » February 2011 were assessed retrospectively. CT attenuation coefficients were measured in Hounsfield Units (HU) using regions of interest at the level of the pulmonary trunk. The average pixel value, standard deviation (SD), maximum, and minimum were recorded. For each of these variables a mean value was then calculated and compared for these two CTPA protocols. Minimum opacification of 200 HU was achieved in 98% of the TBP sample but only 90% of the SPP sample. The average CT attenuation over the pulmonary trunk for the SPP was 329 (SD = ±21) HU, whereas for the TBP it was 396 (SD = ±22) HU (P = 0.0017). The TBP also recorded higher maximum (P = 0.0024) and minimum (P = 0.0039) levels of opacification. This study has found that a TBP resulted in significantly better opacification of the pulmonary trunk than the SPP.« less
Step climbing capacity in patients with pulmonary hypertension.
Fox, Benjamin Daniel; Langleben, David; Hirsch, Andrew; Boutet, Kim; Shimony, Avi
2013-01-01
Patients with pulmonary hypertension (PH) typically have exercise intolerance and limitation in climbing steps. To explore the exercise physiology of step climbing in PH patients, on a laboratory-based step test. We built a step oximetry system from an 'aerobics' step equipped with pressure sensors and pulse oximeter linked to a computer. Subjects mounted and dismounted from the step until their maximal exercise capacity or 200 steps was achieved. Step-count, SpO(2) and heart rate were monitored throughout exercise and recovery. We derived indices of exercise performance, desaturation and heart rate. A 6-min walk test and serum NT-proBrain Natriuretic Peptide (BNP) level were measured. Lung function tests and hemodynamic parameters were extracted from the medical record. Eighty-six subjects [52 pulmonary arterial hypertension (PAH), 14 chronic thromboembolic PH (CTEPH), 20 controls] were recruited. Exercise performance (climbing time, height gained, velocity, energy expenditure, work-rate and climbing index) on the step test was significantly worse with PH and/or worsening WHO functional class (ANOVA, p < 0.001). There was a good correlation between exercise performance on the step and 6-min walking distance-climb index (r = -0.77, p < 0.0001). The saturation deviation (mean of SpO(2) values <95 %) on the step test correlated with diffusion capacity of the lung (ρ = -0.49, p = 0.001). No correlations were found between the step test indices and other lung function tests, hemodynamic parameters or NT-proBNP levels. Patients with PAH/CTEPH have significant limitation in step climbing ability that correlates with functional class and 6-min walking distance. This is a significant impediment to their daily activities.
Spieth, P M; Güldner, A; Uhlig, C; Bluth, T; Kiss, T; Conrad, C; Bischlager, K; Braune, A; Huhle, R; Insorsi, A; Tarantino, F; Ball, L; Schultz, M J; Abolmaali, N; Koch, T; Pelosi, P; Gama de Abreu, M
2018-03-01
Experimental studies showed that controlled variable ventilation (CVV) yielded better pulmonary function compared to non-variable ventilation (CNV) in injured lungs. We hypothesized that CVV improves intraoperative and postoperative respiratory function in patients undergoing open abdominal surgery. Fifty patients planned for open abdominal surgery lasting >3 h were randomly assigned to receive either CVV or CNV. Mean tidal volumes and PEEP were set at 8 ml kg -1 (predicted body weight) and 5 cm H 2 O, respectively. In CVV, tidal volumes varied randomly, following a normal distribution, on a breath-by-breath basis. The primary endpoint was the forced vital capacity (FVC) on postoperative Day 1. Secondary endpoints were oxygenation, non-aerated lung volume, distribution of ventilation, and pulmonary and extrapulmonary complications until postoperative Day 5. FVC did not differ significantly between CVV and CNV on postoperative Day 1, 61.5 (standard deviation 22.1) % vs 61.9 (23.6) %, respectively; mean [95% confidence interval (CI)] difference, -0.4 (-13.2-14.0), P=0.95. Intraoperatively, CVV did not result in improved respiratory function, haemodynamics, or redistribution of ventilation compared to CNV. Postoperatively, FVC, forced expiratory volume at the first second (FEV 1 ), and FEV 1 /FVC deteriorated, while atelectasis volume and plasma levels of interleukin-6 and interleukin-8 increased, but values did not differ between groups. The incidence of postoperative pulmonary and extrapulmonary complications was comparable in CVV and CNV. In patients undergoing open abdominal surgery, CVV did not improve intraoperative and postoperative respiratory function compared with CNV. NCT 01683578. Copyright © 2017 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.
Kanjanahattakij, Napatt; Sirinvaravong, Natee; Aguilar, Francisco; Agrawal, Akanksha; Krishnamoorthy, Parasuram; Gupta, Shuchita
2018-01-01
In patients with heart failure with preserved ejection fraction (HFpEF), worse kidney function is associated with worse overall cardiac mechanics. Right ventricular stroke work index (RVSWI) is a parameter of right ventricular function. The aim of our study was to determine the relationship between RVSWI and glomerular filtration rate (GFR) in patients with HFpEF. This was a single-center cross-sectional study. HFpEF is defined as patients with documented heart failure with ejection fraction > 50% and pulmonary wedge pressure > 15 mm Hg from right heart catheterization. RVSWI (normal value 8-12 g/m/beat/m2) was calculated using the formula: RVSWI = 0.0136 × stroke volume index × (mean pulmonary artery pressure - mean right atrial pressure). Univariate and multivariate linear regression analysis was performed to study the correlation between RVSWI and GFR. Ninety-one patients were included in the study. The patients were predominantly female (n = 64, 70%) and African American (n = 61, 67%). Mean age was 66 ± 12 years. Mean GFR was 59 ± 35 mL/min/1.73 m2. Mean RVSWI was 11 ± 6 g/m/beat/m2. Linear regression analysis showed that there was a significant independent inverse relationship between RVSWI and GFR (unstandardized coefficient = -1.3, p = 0.029). In the subgroup with combined post and precapillary pulmonary hypertension (Cpc-PH) the association remained significant (unstandardized coefficient = -1.74, 95% CI -3.37 to -0.11, p = 0.04). High right ventricular workload indicated by high RVSWI is associated with worse renal function in patients with Cpc-PH. Further prospective studies are needed to better understand this association. © 2018 S. Karger AG, Basel.
Yamashita, H; Onodera, S; Imamoto, T; Obara, A; Tanazawa, S; Takashio, T; Morimoto, H; Inoue, H
1989-10-01
To clarify the effects of right ventricular (RV) pressure overload on functional and geometrical interference and interdependency between the right and left ventricle, both ventricular internal diameters were measured by the microcrystal technique during lycopodium induced pulmonary embolization in the dog. By repeated embolization, RV systolic pressure was increased progressively until it reached a peak value of about 60-70 mmHg, then it began to fall. At the same time, the hemodynamics deteriorated progressively resulting in death. During the experiment, gradual leftward displacement of the interventricular septum (IVS) without any change in left ventricular (LV) free wall geometry was observed. In pulmonary embolic shock, which showed a fall in LV pressure to about 60 mmHg and cardiac output to about 40% of control, the leftward displacement of IVS became marked, and the cooperative movement of IVS to LV contraction disappeared. The IVS position during acute RV pressure overload was able to account for the transseptal pressure gradient. The importance of IVS position and motion in cardiac function during acute RV pressure overload was stressed. Furthermore, to establish the theoretical treatment in acute cardiopulmonary resuscitation, ligation of the descending aorta (AoL) or norepinephrine ("N") or isoproterenol ("I") administration were examined in a canine pulmonary embolic shock model. AoL or "N" improved the deteriorated hemodynamics with restoration of biventricular geometry. However, "I" did not restore the biventricular geometry despite the transiently improved hemodynamics, and the experimental animals were unable to survive. These results suggest the importance of the maintainance of systemic pressure for the restoration of failed RV function. Further integrated studies are required to understand biventricular interference and interdependency.
Trajectories of change in cognitive function in people with chronic obstructive pulmonary disease.
Park, Soo Kyung
2018-04-01
To describe changes in cognitive function, as measured by the trail making test; to identify distinct patterns of change in cognitive function; and to examine predictors of change in cognitive function in people with severe chronic obstructive pulmonary disease. How cognitive function changes in people with chronic obstructive pulmonary disease and what factors influence those changes over time is not well known, despite the fact that it declines rapidly in this population and significantly impacts functional decline in healthy older adults. A secondary analysis and longitudinal study with a follow-up period of 3 years. A data set from the National Emphysema Treatment Trial provided participant data. Patients with severe chronic obstructive pulmonary disease (n = 307) were recruited at a clinical site. Several demographic and clinical measures were assessed at baseline. Trail making test scores were measured at baseline, 1, 2 and 3 years. Cognitive function was stable for 3 years in people with chronic obstructive pulmonary disease. However, four distinct patterns of change in cognitive function were identified. Age, education, 6-min walk distance and cognitive impairment scores at baseline on the trail making test Part B were significant predictors of worsening cognitive function and below-average cognitive function over 3 years. These findings suggest that increasing exercise capacity improves cognitive function and delays deterioration of cognitive function in people with COPD. Understanding the trajectories of change in cognitive function and predictors of change in cognitive function over 3 years may enable health care providers to identify patients at greatest risk of developing mental deterioration and those who might benefit from interventions to improve cognitive function. Health care providers should periodically assess and frequently screen people with COPD for cognitive function. © 2018 John Wiley & Sons Ltd.
Pulmonary Function, Muscle Strength and Mortality in Old Age
Buchman, A. S.; Boyle, P. A.; Wilson, R.S.; Gu, Liping; Bienias, Julia L.; Bennett, D. A.
2009-01-01
Numerous reports have linked extremity muscle strength with mortality but the mechanism underlying this association is not known. We used data from 960 older persons without dementia participating in the Rush Memory and Aging Project to test two sequential hypotheses: first, that extremity muscle strength is a surrogate for respiratory muscle strength, and second, that the association of respiratory muscle strength with mortality is mediated by pulmonary function. In a series of proportional hazards models, we first demonstrated that the association of extremity muscle strength with mortality was no longer significant after including a term for respiratory muscle strength, controlling for age, sex, education, and body mass index. Next, the association of respiratory muscle strength with mortality was attenuated by more than 50% and no longer significant after including a term for pulmonary function. The findings were unchanged after controlling for cognitive function, parkinsonian signs, physical frailty, balance, physical activity, possible COPD, use of pulmonary medications, vascular risk factors including smoking, chronic vascular diseases, musculoskeletal joint pain, and history of falls. Overall, these findings suggest that pulmonary function may partially account for the association of muscle strength and mortality. PMID:18755207
Role of Hypoxia-Induced Brain Derived Neurotrophic Factor in Human Pulmonary Artery Smooth Muscle
Hartman, William; Helan, Martin; Smelter, Dan; Sathish, Venkatachalem; Thompson, Michael; Pabelick, Christina M.; Johnson, Bruce; Prakash, Y. S.
2015-01-01
Background Hypoxia effects on pulmonary artery structure and function are key to diseases such as pulmonary hypertension. Recent studies suggest that growth factors called neurotrophins, particularly brain-derived neurotrophic factor (BDNF), can influence lung structure and function, and their role in the pulmonary artery warrants further investigation. In this study, we examined the effect of hypoxia on BDNF in humans, and the influence of hypoxia-enhanced BDNF expression and signaling in human pulmonary artery smooth muscle cells (PASMCs). Methods and Results 48h of 1% hypoxia enhanced BDNF and TrkB expression, as well as release of BDNF. In arteries of patients with pulmonary hypertension, BDNF expression and release was higher at baseline. In isolated PASMCs, hypoxia-induced BDNF increased intracellular Ca2+ responses to serotonin: an effect altered by HIF1α inhibition or by neutralization of extracellular BDNF via chimeric TrkB-Fc. Enhanced BDNF/TrkB signaling increased PASMC survival and proliferation, and decreased apoptosis following hypoxia. Conclusions Enhanced expression and signaling of the BDNF-TrkB system in PASMCs is a potential mechanism by which hypoxia can promote changes in pulmonary artery structure and function. Accordingly, the BDNF-TrkB system could be a key player in the pathogenesis of hypoxia-induced pulmonary vascular diseases, and thus a potential target for therapy. PMID:26192455
Rehabilitation of patients admitted to a respiratory intensive care unit.
Nava, S
1998-07-01
Pulmonary rehabilitation has been shown to be of benefit to clinically stable patients with chronic obstructive pulmonary disease (COPD). This study examined the effect of pulmonary rehabilitation on some physiologic variables in COPD patients recovering from an episode of acute respiratory failure. A prospective, randomized study. A respiratory intensive care unit (RICU). Eighty COPD patients recovering from an episode of acute respiratory failure were randomized in a 3:1 fashion to receive stepwise pulmonary rehabilitation (group A, n=60 patients) or standard medical therapy (group B, n=20 patients). Improvements in exercise tolerance, sense of breathlessness, respiratory muscle function, and pulmonary function test values were measured, respectively, by exercise capacity (6-minute walking distance [6MWD]), dyspnea score (Visual Analog Scale [VAS]), maximal inspiratory pressure (MIP), forced expiratory volume in 1 second (FEV1), and forced vital capacity (FVC). Group A received pulmonary rehabilitation that consisted of passive mobilization (step I), early deambulation (step II), respiratory and lower skeletal muscle training (step III), and if the patients were able, complete lower extremity training on a treadmill (step IV). Group B received standard medical therapy plus a basic deambulation program. Sixty-one of 80 patients were mechanically ventilated at admission to the unit and most of them were bedridden. Twelve of the 60 group A patients and 4 of the 20 group B patients died during their RICU stay, and 9 patients required invasive mechanical ventilation at home after their discharge. The total length of RICU stay was 38+/-14 days for patients in group A versus 33.2+/-11 days for those in group B. Most patients from both groups regained the ability to walk, either unaided or aided. At discharge, 6 MWD results were significantly improved (p < .001) in Group A only. MIP improved in Group A only (p < .05), while VAS scores improved in both groups, but the improvement was more marked in group A (p < .001) than in group B (p < .05). COPD patients who were admitted to a RICU in critical condition after an episode of acute respiratory failure and who, in most cases, required mechanical ventilation benefited from comprehensive early pulmonary rehabilitation, compared with patients who received standard medical therapy and progressive ambulation.
Nakatani, S; Garcia, M J; Firstenberg, M S; Rodriguez, L; Grimm, R A; Greenberg, N L; McCarthy, P M; Vandervoort, P M; Thomas, J D
1999-09-01
The study assessed whether hemodynamic parameters of left atrial (LA) systolic function could be estimated noninvasively using Doppler echocardiography. Left atrial systolic function is an important aspect of cardiac function. Doppler echocardiography can measure changes in LA volume, but has not been shown to relate to hemodynamic parameters such as the maximal value of the first derivative of the pressure (LA dP/dt(max)). Eighteen patients in sinus rhythm were studied immediately before and after open heart surgery using simultaneous LA pressure measurements and intraoperative transesophageal echocardiography. Left atrial pressure was measured with a micromanometer catheter, and LA dP/dt(max) during atrial contraction was obtained. Transmitral and pulmonary venous flow were recorded by pulsed Doppler echocardiography. Peak velocity, and mean acceleration and deceleration, and the time-velocity integral of each flow during atrial contraction was measured. The initial eight patients served as the study group to derive a multilinear regression equation to estimate LA dP/dt(max) from Doppler parameters, and the latter 10 patients served as the test group to validate the equation. A previously validated numeric model was used to confirm these results. In the study group, LA dP/dt(max) showed a linear relation with LA pressure before atrial contraction (r = 0.80, p < 0.005), confirming the presence of the Frank-Starling mechanism in the LA. Among transmitral flow parameters, mean acceleration showed the strongest correlation with LA dP/dt(max) (r = 0.78, p < 0.001). Among pulmonary venous flow parameters, no single parameter was sufficient to estimate LA dP/dt(max) with an r2 > 0.30. By stepwise and multiple linear regression analysis, LA dP/dt(max) was best described as follows: LA dP/dt(max) = 0.1 M-AC +/- 1.8 P-V - 4.1; r = 0.88, p < 0.0001, where M-AC is the mean acceleration of transmitral flow and P-V is the peak velocity of pulmonary venous flow during atrial contraction. This equation was tested in the latter 10 patients of the test group. Predicted and measured LA dP/dt(max) correlated well (r = 0.90, p < 0.0001). Numerical simulation verified that this relationship held across a wide range of atrial elastance, ventricular relaxation and systolic function, with LA dP/dt(max) predicted by the above equation with r = 0.94. A combination of transmitral and pulmonary venous flow parameters can provide a hemodynamic assessment of LA systolic function.
NASA Technical Reports Server (NTRS)
Nakatani, S.; Garcia, M. J.; Firstenberg, M. S.; Rodriguez, L.; Grimm, R. A.; Greenberg, N. L.; McCarthy, P. M.; Vandervoort, P. M.; Thomas, J. D.
1999-01-01
OBJECTIVES: The study assessed whether hemodynamic parameters of left atrial (LA) systolic function could be estimated noninvasively using Doppler echocardiography. BACKGROUND: Left atrial systolic function is an important aspect of cardiac function. Doppler echocardiography can measure changes in LA volume, but has not been shown to relate to hemodynamic parameters such as the maximal value of the first derivative of the pressure (LA dP/dt(max)). METHODS: Eighteen patients in sinus rhythm were studied immediately before and after open heart surgery using simultaneous LA pressure measurements and intraoperative transesophageal echocardiography. Left atrial pressure was measured with a micromanometer catheter, and LA dP/dt(max) during atrial contraction was obtained. Transmitral and pulmonary venous flow were recorded by pulsed Doppler echocardiography. Peak velocity, and mean acceleration and deceleration, and the time-velocity integral of each flow during atrial contraction was measured. The initial eight patients served as the study group to derive a multilinear regression equation to estimate LA dP/dt(max) from Doppler parameters, and the latter 10 patients served as the test group to validate the equation. A previously validated numeric model was used to confirm these results. RESULTS: In the study group, LA dP/dt(max) showed a linear relation with LA pressure before atrial contraction (r = 0.80, p < 0.005), confirming the presence of the Frank-Starling mechanism in the LA. Among transmitral flow parameters, mean acceleration showed the strongest correlation with LA dP/dt(max) (r = 0.78, p < 0.001). Among pulmonary venous flow parameters, no single parameter was sufficient to estimate LA dP/dt(max) with an r2 > 0.30. By stepwise and multiple linear regression analysis, LA dP/dt(max) was best described as follows: LA dP/dt(max) = 0.1 M-AC +/- 1.8 P-V - 4.1; r = 0.88, p < 0.0001, where M-AC is the mean acceleration of transmitral flow and P-V is the peak velocity of pulmonary venous flow during atrial contraction. This equation was tested in the latter 10 patients of the test group. Predicted and measured LA dP/dt(max) correlated well (r = 0.90, p < 0.0001). Numerical simulation verified that this relationship held across a wide range of atrial elastance, ventricular relaxation and systolic function, with LA dP/dt(max) predicted by the above equation with r = 0.94. CONCLUSIONS: A combination of transmitral and pulmonary venous flow parameters can provide a hemodynamic assessment of LA systolic function.
Does exercise pulmonary hypertension exist?
Lau, Edmund M; Chemla, Denis; Whyte, Kenneth; Kovacs, Gabor; Olschewski, Horst; Herve, Philippe
2016-09-01
The exercise definition of pulmonary hypertension using a mean pulmonary artery pressure threshold of greater than 30 mmHg was abandoned following the 4th World Pulmonary Hypertension Symposium in 2008, as this definition was not supported by evidence and healthy individuals frequently exceed this threshold. Meanwhile, the clinical value of exercise pulmonary hemodynamic testing has also been questioned. Recent data support the notion that an abnormal pulmonary hemodynamic response during exercise (or exercise pulmonary hypertension) is associated with symptoms and exercise limitation. Pathophysiologic mechanisms accounting for the development of exercise pulmonary hypertension include increased vascular resistance, excessive elevation in left atrial pressure and/or increased volume of trapped air during exercise, resulting in a steep rise in pulmonary artery pressure relative to cardiac output. Recent evidence suggests that exercise pulmonary hypertension may be defined by a mean pulmonary artery pressure surpassing 30 mmHg together with a simultaneous total pulmonary resistance exceeding 3 WU. Exercise pulmonary hypertension is a clinically relevant entity and an improved definition has been suggested based on new evidence. Exercise pulmonary hemodynamics may help unmask early or latent disease, particularly in populations that are at high risk for the development of pulmonary hypertension.
Gielen, Stephan; Laughlin, M Harold; O'Conner, Christopher; Duncker, Dirk J
2015-01-01
Over the last decades exercise training has evolved into an established evidence-based therapeutic strategy with prognostic benefits in many cardiovascular diseases (CVDs): In stable coronary artery disease (CAD) exercise training attenuates disease progression by beneficially influencing CVD risk factors (i.e., hyperlipidemia, hypertension) and coronary endothelial function. In heart failure (HF) with reduced ejection fraction (HFrEF) training prevents the progressive loss of exercise capacity by antagonizing peripheral skeletal muscle wasting and by promoting left ventricular reverse remodeling with reduction in cardiomegaly and improvement of ejection fraction. Novel areas for exercise training interventions include HF with preserved ejection fraction (HFpEF), pulmonary hypertension, and valvular heart disease. In HFpEF, randomized studies indicate a lusitropic effect of training on left ventricular diastolic function associated with symptomatic improvement of exercise capacity. In pulmonary hypertension, reductions in pulmonary artery pressure were observed following endurance exercise training. Recently, innovative training methods such as high-intensity interval training, resistance training and others have been introduced. Although their prognostic value still needs to be determined, these approaches may achieve superior improvements in aerobic exercise capacity and gain in muscle mass, respectively. In this review, we give an overview of the prognostic and symptomatic benefits of exercise training in the most common cardiac disease entities. Additionally, key guideline recommendations for the initiation of training programs are summarized. Copyright © 2014 Elsevier Inc. All rights reserved.
Lung radiology and pulmonary function of children chronically exposed to air pollution.
Calderón-Garcidueñas, Lilian; Mora-Tiscareño, Antonieta; Fordham, Lynn A; Chung, Charles J; Valencia-Salazar, Gildardo; Flores-Gómez, Silvia; Solt, Anna C; Gomez-del Campo, Alberto; Jardón-Torres, Ricardo; Henríquez-Roldán, Carlos; Hazucha, Milan J; Reed, William
2006-09-01
We analyzed the chest radiographs (CXRs) of 249 clinically healthy children, 230 from southwest Mexico City and 19 from Tlaxcala. In contrast to children from Tlaxcala, children from southwest Mexico City were chronically exposed to ozone levels exceeding the U.S. National Ambient Air Quality Standards for an average of 4.7 hr/day and to concentrations of particulate matter (PM) with aerodynamic diameters = 2.5 microm (PM2.5) above the annual standard. CXRs of Mexico City children demonstrated bilateral hyperinflation (151 of 230) and increased linear markings (121 of 230) . Hyperinflation and interstitial markings were significantly more common in Mexico City children (p < 0.0002 and 0.00006 respectively) . Mexico City boys had a higher probability of developing interstitial markings with age (p = 0.004) . Computed tomography (CT) scans were obtained in 25 selected Mexico City children with abnormal CXRs. Mild bronchial wall thickening was seen in 10 of 25, prominent central airways in 4 of 25, air trapping in 8 of 21, and pulmonary nodules in 2 of 21. Only 7.8% of Mexico City children had abnormal lung function tests based on predicted values. These findings are consistent with bronchiolar, peribronchiolar, and/or alveolar duct inflammation, possibly caused by ozone, PM, and lipopolysaccharide exposure. The epidemiologic implications of these findings are important for children residing in polluted environments, because bronchiolar disease could lead to chronic pulmonary disease later in life.
Vom Hove, Maike; Prenzel, Freerk; Uhlig, Holm H; Robel-Tillig, Eva
2014-01-01
To assess and compare long-term pulmonary outcomes in former preterm-born, very low birth weight (VLBW) children with and without bronchopulmonary dysplasia (BPD) born in the surfactant era. Pulmonary function tests (ie, spirometry, body plethysmography, and gas transfer testing) were performed in children with a history of VLBW and BPD (n = 28) and compared with a matched preterm-born VLBW control group (n = 28). Medical history was evaluated by questionnaire. At time of follow-up (mean age, 9.5 years), respiratory symptoms (36% vs 8%) and receipt of asthma medication (21% vs 0%) were significantly more frequent in the preterm-born children with previous BPD than in those with no history of BPD. The children with a history of BPD had significantly lower values for forced expiratory volume in 1 second (z-score -1.27 vs -0.4; P = .008), forced vital capacity (z-score -1.39 vs -0.71 z-score; P = .022), and forced expiratory flow rate at 50% of forced vital capacity (z-score -2.21 vs -1.04; P = .048) compared with the preterm control group. Preterm-born children with a history of BPD are significantly more likely to have lung function abnormalities, such as airway obstruction and respiratory symptoms, at school age compared with preterm-born children without BPD. Copyright © 2014 Mosby, Inc. All rights reserved.
Analysis of electrocardiogram in chronic obstructive pulmonary disease patients.
Lazović, Biljana; Svenda, Mirjana Zlatković; Mazić, Sanja; Stajić, Zoran; Delić, Marina
2013-01-01
Chronic obstructive pulmonary disease is the fourth leading cause of mortality worldwide. It is defined as a persistent airflow limitation usually progressive and not fully reversible to treatment. The diagnosis of chronic obstructive pulmonary disease and severity of disease is confirmed by spirometry. Chronic obstructive pulmonary disease produces electrical changes in the heart which shows characteristic electrocardiogram pattern. The aim of this study was to observe and evaluate diagnostic values of electrocardiogram changes in chronic obstructive pulmonary disease patients with no other comorbidity. We analyzed 110 electrocardiogram findings in clinically stable chronic obstructive pulmonary disease patients and evaluated the forced expiratory volume in the first second, ratio of forces expiratory volume in the first second to the fixed vital capacity, chest radiographs and electrocardiogram changes such as p wave height, QRS axis and voltage, right bundle branch block, left bundle branch block, right ventricular hypertrophy, T wave inversion in leads V1-V3, S1S2S3 syndrome, transition zone in praecordial lead and QT interval. We found electrocardiogram changes in 64% patients, while 36% had normal electrocardiogram. The most frequent electrocardiogram changes observed were transition zone (76.36%) low QRS (50%) and p pulmonale (14.54%). Left axis deviation was observed in 27.27% patients. Diagnostic values of electrocardiogram in patients with chronic obstructive pulmonary disease suggest that chronic obstructive pulmonary disease patients should be screened electrocardiographically in addition to other clinical investigations.
[Pulmonary function in patients with infiltrative pulmonary tuberculosis].
Nefedov, V B; Popova, L A; Shergina, E A
2007-01-01
Vital capacity (VC), forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), FEV1/VC%, PEF, MEF25, MEF50, MEF75, TLC, TGV, pulmonary residual volume (PRV), R(aw), R(in),, R(ex), DLCO-SB, DLCO-SS, PaO2, and PaCO2 were determined in 103 patients with infiltrative pulmonary tuberculosis. Pulmonary dysfunction was detected in 83.5% of the patients. Changes were found in lung volumes and capacities in 63.1%, impaired bronchial patency and pulmonary gas exchange dysfunction were in 60.2 and 41.7%, respectively. The changes in pulmonary volumes and capacities appeared as increased PRV, decreased VC and FVC, and decreased and increased TGV and TLC; impaired bronchial patency presented as decreased PEF, MEF25, MEF50, MEF75, FEV1/VC% and increased R(aw) R(in), and R(ex); pulmonary gas exchange dysfunction manifested itself as reduced DLCO-SB, DLCO-SS, and PaO2 and decreased and increased PaCO2. The magnitude of the observed functional changes was generally slight. Significant disorders were observed rarely and very pronounced ones were exceptional.
[Pulmonary function in patients with disseminated pulmonary tuberculosis].
Nefedov, V B; Shergina, E A; Popova, L A
2007-01-01
Vital capacity (VC), forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), FEV1/VC%, PEF, MEF25%, MEF50%, MEF75%, TLS, TGV, pulmonary residual volume (PRV), Raw, Rin, Rex, DLCO-SB, DLCO-SS, PaO2, and PaCO2 were determined in 29 patients with disseminated pulmonary tuberculosis. Pulmonary dysfunction was detected in 93.1% of the patients. Changes were found in lung volumes and capacities in 65.5%, impaired bronchial patency and pulmonary gas exchange dysfunction were in 79.3 and 37.9%, respectively. The changes in pulmonary volumes and capacities appeared as increased PRV, decreased VC, FVC, and TLS, decreased and increased TGV; impaired bronchial patency presented as decreased PEF, MEF25%, MEF50%, MEF75%, and FEV1/VC% and increased Raw, Rin, and Rex; pulmonary gas exchange dysfunction manifested itself as reduced DLCO-SS and PaO2 and decreased and increased PaCO2. The observed functional changes varied from slight to significant and pronounced with a preponderance of small disorders, a lower detection rate of significant disorders, and rare detection of very pronounced ones.
Culver, Bruce H; Graham, Brian L; Coates, Allan L; Wanger, Jack; Berry, Cristine E; Clarke, Patricia K; Hallstrand, Teal S; Hankinson, John L; Kaminsky, David A; MacIntyre, Neil R; McCormack, Meredith C; Rosenfeld, Margaret; Stanojevic, Sanja; Weiner, Daniel J
2017-12-01
The American Thoracic Society committee on Proficiency Standards for Pulmonary Function Laboratories has recognized the need for a standardized reporting format for pulmonary function tests. Although prior documents have offered guidance on the reporting of test data, there is considerable variability in how these results are presented to end users, leading to potential confusion and miscommunication. A project task force, consisting of the committee as a whole, was approved to develop a new Technical Standard on reporting pulmonary function test results. Three working groups addressed the presentation format, the reference data supporting interpretation of results, and a system for grading quality of test efforts. Each group reviewed relevant literature and wrote drafts that were merged into the final document. This document presents a reporting format in test-specific units for spirometry, lung volumes, and diffusing capacity that can be assembled into a report appropriate for a laboratory's practice. Recommended reference sources are updated with data for spirometry and diffusing capacity published since prior documents. A grading system is presented to encourage uniformity in the important function of test quality assessment. The committee believes that wide adoption of these formats and their underlying principles by equipment manufacturers and pulmonary function laboratories can improve the interpretation, communication, and understanding of test results.
Wang, W; Erf, G F; Wideman, R F
2002-11-01
Intravenous endotoxin has been shown to trigger a delayed pulmonary hypertensive response that varies widely in magnitude and duration among individual broilers. It was proposed that this individual variability may reflect immunological differences acquired during previous respiratory challenges that might have subsequently altered the endotoxin-initiated biochemical cascade. In Experiment 1, we tested the hypothesis that, when compared with broilers reared in clean stainless steel cages (Cage group), broilers reared on floor litter (Floor group) should experience a greater respiratory challenge and therefore may consistently exhibit a more enhanced pulmonary hypertensive response to intravenous endotoxin. Birds in the Cage group were grown in stainless steel cages at a low density (72 birds/8 m2 chamber), and fecal and dander materials were removed daily. Birds in the Floor group were reared on wood-shavings litter at a higher density (110 birds/8 m2 chamber). Pulmonary and systemic mean arterial pressures and blood-gas values were evaluated prior to and following the intravenous administration of 1 mg Salmonella typhimurium endotoxin. Broilers in the Floor and Cage groups exhibited pulmonary hypertensive responses to endotoxin that were very similar in terms of time of onset, duration, and magnitude, as well as variability in the response among individuals. Systemic hypotension also developed similarly in both groups following endotoxin injection. Blood-gas values indicated that the partial pressure of CO2 and the HCO3- concentration in arterial blood were higher (P < 0.05) in the Floor group than in the Cage group prior to and subsequent to the endotoxin injection. In Experiment 2, we reevaluated the effect of a dirty vs. a clean environment on blood-gas values using a different strain of broilers, and confirmed the negative impact of floor rearing on blood-gas values. We conclude that broilers reared on the floor inhaled litter dust and noxious fumes, which impaired pulmonary gas exchange and increased the arterial partial pressure of CO2 when compared with broilers reared in clean stainless steel cages. Nevertheless, the pulmonary hypertensive response to endotoxin did not differ between broilers reared on the floor and those in cages.
2011-01-01
Background Airway Bypass is a catheter-based, bronchoscopic procedure in which new passageways are created that bypass the collapsed airways, enabling trapped air to exit the lungs. The Exhale Airway Stents for Emphysema (EASE) Trial was designed to investigate whether Exhale® Drug-Eluting Stents, placed in new passageways in the lungs, can improve pulmonary function and reduce breathlessness in severely hyperinflated, homogeneous emphysema patients (NCT00391612). Methods/Design The multi-center, randomized, double-blind, sham-controlled trial design was posted on http://www.clinicaltrials.gov in October 2006. Because Bayesian statistics are used for the analysis, the proposed enrollment ranged from 225 up to 450 subjects at up to 45 institutions. Inclusion criteria are: high resolution CT scan with evidence of homogeneous emphysema, post-bronchodilator pulmonary function tests showing: a ratio of FEV1/FVC < 70%, FEV1≤50% of predicted or FEV1 < 1 liter, RV/TLC≥0.65 at screening, marked dyspnea score ≥2 on the modified Medical Research Council scale of 0-4, a smoking history of at least 20 pack years and stopped smoking for at least 8 weeks prior to enrollment. Following 16 to 20 supervised pulmonary rehabilitation sessions, subjects were randomized 2:1 to receive either a treatment (Exhale® Drug-Eluting Stent) or a sham bronchoscopy. A responder analysis will evaluate the co-primary endpoints of an FVC improvement ≥12% of the patient baseline value and modified Medical Research Council dyspnea scale improvement (reduction) ≥1 point at the 6-month follow-up visit. Discussion If through the EASE Trial, Airway Bypass is shown to improve pulmonary function and reduce dyspnea while demonstrating an acceptable safety profile, then homogeneous patients will have a minimally invasive treatment option with meaningful clinical benefit. Trial Registration ClinicalTrials.gov: NCT00391612 PMID:21214899
Di Marco, Fabiano; Terraneo, Silvia; Job, Sara; Rinaldo, Rocco Francesco; Sferrazza Papa, Giuseppe Francesco; Roggi, Maria Adelaide; Santus, Pierachille; Centanni, Stefano
2017-06-01
The need for additional research on symptomatic smokers with normal spirometry has been recently emphasized. Albeit not meeting criteria for Chronic obstructive pulmonary disease (COPD) diagnosis, symptomatic smokers may experience activity limitation, evidence of airway disease, and exacerbations. We, therefore, evaluated whether symptomatic smokers with borderline spirometry (post-bronchodilator FEV 1 /FVC ratio between 5th to 20th percentile of predicted values) have pulmonary function abnormalities at rest and ventilatory constraints during exercise. 48 subjects (aged 60 ± 8 years, mean ± SD, 73% males, 16 healthy, and 17 symptomatic smokers) underwent cardiopulmonary exercise testing (CPET), body plethysmography, nitrogen single-breath washout test (N 2 SBW), lung diffusion for carbon monoxide (DLCO), and forced oscillation technique (FOT). Compared to healthy subjects, symptomatic smokers showed: 1) reduced breathing reserve (36 ± 17 vs. 49 ± 12%, P = 0.050); 2) exercise induced dynamic hyperinflation (-0.20 ± 0.17 vs. -0.03 ± 0.21 L, P = 0.043); 3) higher residual volume (158 ± 22 vs. 112 ± 22%, P < 0.001); 4) phase 3 slope at N 2 SBW (4.7 ± 2.1 vs. 1.4 ± 0.6%, P < 0.001); 5) no significant differences in DLCO and FOT results. In smokers with borderline spirometry, CPET and second-line pulmonary function tests may detect obstructive pattern. These subjects should be referred for second line testing, to obtain a diagnosis, or at least to clarify the mechanisms underlying symptoms. Whether the natural history of these patients is similar to COPD, and they deserve a similar therapeutic approach is worth investigating. Copyright © 2017 Elsevier Ltd. All rights reserved.
Lammers, Astrid E; Adatia, Ian; Cerro, Maria Jesus Del; Diaz, Gabriel; Freudenthal, Alexandra Heath; Freudenthal, Franz; Harikrishnan, S; Ivy, Dunbar; Lopes, Antonio A; Raj, J Usha; Sandoval, Julio; Stenmark, Kurt; Haworth, Sheila G
2011-08-02
The members of the Pediatric Task Force of the Pulmonary Vascular Research Institute (PVRI) were aware of the need to develop a functional classification of pulmonary hypertension in children. The proposed classification follows the same pattern and uses the same criteria as the Dana Point pulmonary hypertension specific classification for adults. Modifications were necessary for children, since age, physical growth and maturation influences the way in which the functional effects of a disease are expressed. It is essential to encapsulate a child's clinical status, to make it possible to review progress with time as he/she grows up, as consistently and as objectively as possible. Particularly in younger children we sought to include objective indicators such as thriving, need for supplemental feeds and the record of school or nursery attendance. This helps monitor the clinical course of events and response to treatment over the years. It also facilitates the development of treatment algorithms for children. We present a consensus paper on a functional classification system for children with pulmonary hypertension, discussed at the Annual Meeting of the PVRI in Panama City, February 2011.
Secondary Pulmonary Hypertension and Right-Sided Heart Failure at Presentation in Grave's Disease.
Ganeshpure, Swapnil Panjabrao; Vaidya, Gaurang Nandkishor; Gattani, Vipul
2012-01-01
A young female presented with evidence of right-sided heart failure and was subsequently found to have significant pulmonary artery hypertension (PAH). Because of her normal left ventricular function and pulmonary capillary wedge pressure, the most probable site of etiology seemed to be the pulmonary vasculature. All the common possible secondary causes of PAH were ruled out, but during the investigations, she was found to have elevated thyroid function tests compatible with the diagnosis of Grave's disease. The treatment of Grave's disease, initially by medications and subsequently by radioiodine therapy, was associated with a significant reduction in the pulmonary artery systolic pressure. The purpose of this case report is to highlight one of the unusual and underdiagnosed presentations of Grave's disease.
Liu, Jie; Fei, Lei; Huang, Guang-Qing; Shang, Xiao-Ke; Liu, Mei; Pei, Zhi-Jun; Zhang, Yong-Xue
2018-05-01
Right heart catheterization is commonly used to measure right ventricle hemodynamic parameters and is the gold standard for pulmonary arterial hypertension diagnosis; however, it is not suitable for patients' long-term follow-up. Non-invasive echocardiography and nuclear medicine have been applied to measure right ventricle anatomy and function, but the guidelines for the usefulness of clinical parameters remain to be established. The goal of this study is to identify reliable clinical parameters of right ventricle function in pulmonary arterial hypertension patients and analyze the relationship of these clinical parameters with the disease severity of pulmonary arterial hypertension. In this study, 23 normal subjects and 23 pulmonary arterial hypertension patients were recruited from January 2015 to March 2016. Pulmonary arterial hypertension patients were classified into moderate and severe pulmonary arterial hypertension groups according to their mean pulmonary arterial pressure levels. All the subjects were subjected to physical examination, chest X-ray, 12-lead electrocardiogram, right heart catheterization, two-dimensional echocardiography, and technetium 99m ( 99m Tc) myocardial perfusion imaging. Compared to normal subjects, the right heart catheterization indexes including right ventricle systolic pressure, right ventricle end diastolic pressure, pulmonary artery systolic pressure, pulmonary artery diastolic pressure, pulmonary vascular resistance, and right ventricle end systolic pressure increased in pulmonary arterial hypertension patients and were correlated with mean pulmonary arterial pressure levels. Echocardiography parameters, including tricuspid regurgitation peak velocity, tricuspid regurgitation pressure gradient, tricuspid annular plane systolic excursion and fractional area, right ventricle-myocardial performance index, were significantly associated with the mean pulmonary arterial pressure levels in pulmonary arterial hypertension patients. Furthermore, myocardial perfusion imaging was not observed in the normal subjects but in pulmonary arterial hypertension patients, especially severe pulmonary arterial hypertension subgroup, and showed potential diagnostic properties for pulmonary arterial hypertension. In conclusion, mean pulmonary arterial pressure levels are correlated with several right heart catheterization and echocardiography markers in pulmonary arterial hypertension patients; echocardiography and 99m Tc myocardial perfusion can be used to evaluate right ventricle performance in pulmonary arterial hypertension patients. Impact statement In this study, we analyzed the clinical parameters for evaluating RV function, including right ventricle catheterization (RHC), echocardiography, and technetium 99m ( 99m Tc) myocardial perfusion imaging (MPI) in normal Asian subjects and PAH patients ( n = 23 for each group). Our results demonstrated that six RHC indexes, four echocardiography indexes and MPI index were significantly altered in PAH patients and correlated with the levels of mean pulmonary arterial pressure. Importantly, we evaluated the diagnostic performance of MPI and found that MPI has a strong diagnostic accuracy in PAH patients. The findings from this study will be of interest to clinical investigators who make diagnosis and therapeutic strategies for PAH patients.
NASA Technical Reports Server (NTRS)
Prisk, G. K.; Guy, Harold J. B.; Elliott, Ann R.; Deutschman, Robert A., III; West, John B.
1993-01-01
We measured pulmonary diffusing capacity (DL), diffusing capacity per unit lung volume, pulmonary capillary blood volume (Vc), membrane diffusing capacity (Dm), pulmonary capillary blood flow or cardiac output (Qc), and cardiac stroke volume (SV) in four subjects exposed to nine days of microgravity. DL in microgravity was elevated compared with preflight standing values and was higher than preflight supine because of the elevation of both Vc and Dm. The elevation in Vc was comparable to that measured supine in 1 G, but the increase in Dm was in sharp contrast to the supine value. We postulate that, in 0 G, pulmonary capillary blood is evenly distributed throughout the lung, providing for uniform capillary filling, leading to an increase in the surface area available for diffusion. By contrast, in the supine 1-G state, the capillaries are less evenly filled, and although a similar increase in blood volume is observed, the corresponding increase in surface area does not occur. DL and its subdivisions showed no adaptive changes from the first measurement 24 h after the start of 0 G to eight days later. Similarly, there were no trends in the postflight data, suggesting that the principal mechanism of these changes was gravitational. The increase in Dm suggests that subclinical pulmonary edema did not result from exposure to 0 G. Qc was modestly increased inflight and decreased postflight compared with preflight standing. Compared with preflight standing, SV was increased 46 percent inflight and decreased 14 percent in the 1st week postflight. There were temporal changes in Qc and SV during 0 G, with the highest values recorded at the first measurement, 24 h into the flight. The lowest values of Qc and SV occurred on the day of return.
Zar, Harvey A; Noe, Frances E; Szalados, James E; Goodrich, Michael D; Busby, Michael G
2002-01-01
A repetitive graphic display of the single breath pulmonary function can indicate changes in cardiac and pulmonary physiology brought on by clinical events. Parallel advances in computer technology and monitoring make real-time, single breath pulmonary function clinically practicable. We describe a system built from a commercially available airway gas monitor and off the shelf computer and data-acquisition hardware. Analog data for gas flow rate, O2, and CO2 concentrations are introduced into a computer through an analog-to-digital conversion board. Oxygen uptake (VO2) and carbon dioxide output (VCO2) are calculated for each breath. Inspired minus expired concentrations for O2 and CO2 are displayed simultaneously with the expired gas flow rate curve for each breath. Dead-space and alveolar ventilation are calculated for each breath and readily appreciated from the display. Graphs illustrating the function of the system are presented for the following clinical scenarios; upper airway obstruction, bronchospasm, bronchopleural fistula, pulmonary perfusion changes and inadequate oxygen delivery. This paper describes a real-time, single breath pulmonary monitoring system that displays three parameters graphed against time: expired flow rate, oxygen uptake and carbon dioxide production. This system allows for early and rapid recognition of treatable conditions that may lead to adverse events without any additional patient measurements or invasive procedures. Monitoring systems similar to the one described in this paper may lead to a higher level of patient safety without any additional patient risk.
Lung Function in Pregnancy in Langerhans Cell Histiocytosis.
Radzikowska, Elżbieta; Wiatr, Elżbieta; Franczuk, Monika; Bestry, Iwona; Roszkowski-Śliż, Kazimierz
2018-01-01
Pulmonary Langerhans cell histiocytosis (LCH) is a rare disease, affecting usually young people. The course of the disease is variable. In some pulmonary LCH patients a severe lung destruction and progression in spite of chemotherapy is observed, but in others just a cessation of smoking induces a regression of the disease. In the present study we seek to determine the influence of pregnancy on pulmonary function in LCH patients, an unchartered area of research. We addressed the issue by investigating eight pregnant women out of the 45 women hospitalized with the diagnosis of pulmonary LCH in the period from 2000 to 2015. For five of the eight pregnant women it was the second gestation. The median follow-up period was 120 months (range 72-175 months). Ten healthy children were born by a C-section. Two spontaneous miscarriages in the seventh week of gestation, and one tubal ectopic pregnancy were recorded. We found that pregnancy did not significantly influence pulmonary function assessed by the following indices: forced expiratory volume in 1 s (FEV1), lung vital capacity (VC), total lung capacity (TLC), residual volume (RV), diffusing capacity of the lungs for carbon monoxide (DLCO), and the distance and arterial oxygen saturation in 6-min walk test. Only one patient in the third trimester of pregnancy experienced bilateral pneumothorax, with persistent air leak. In all patients, delivery and postpartum period were uneventful. We conclude that pregnancy in pulmonary LCH patients is safe and not associated with deterioration of pulmonary function or blood oxygenation.
Influenza A virus-dependent remodeling of pulmonary clock function in a mouse model of COPD
Sundar, Isaac K.; Ahmad, Tanveer; Yao, Hongwei; Hwang, Jae-woong; Gerloff, Janice; Lawrence, B. Paige; Sellix, Michael T.; Rahman, Irfan
2015-01-01
Daily oscillations of pulmonary function depend on the rhythmic activity of the circadian timing system. Environmental tobacco/cigarette smoke (CS) disrupts circadian clock leading to enhanced inflammatory responses. Infection with influenza A virus (IAV) increases hospitalization rates and death in susceptible individuals, including patients with Chronic Obstructive Pulmonary Disease (COPD). We hypothesized that molecular clock disruption is enhanced by IAV infection, altering cellular and lung function, leading to severity in airway disease phenotypes. C57BL/6J mice exposed to chronic CS, BMAL1 knockout (KO) mice and wild-type littermates were infected with IAV. Following infection, we measured diurnal rhythms of clock gene expression in the lung, locomotor activity, pulmonary function, inflammatory, pro-fibrotic and emphysematous responses. Chronic CS exposure combined with IAV infection altered the timing of clock gene expression and reduced locomotor activity in parallel with increased lung inflammation, disrupted rhythms of pulmonary function, and emphysema. BMAL1 KO mice infected with IAV showed pronounced detriments in behavior and survival, and increased lung inflammatory and pro-fibrotic responses. This suggests that remodeling of lung clock function following IAV infection alters clock-dependent gene expression and normal rhythms of lung function, enhanced emphysematous and injurious responses. This may have implications for the pathobiology of respiratory virus-induced airway disease severity and exacerbations. PMID:25923474
van der Molen, Thys; Diamant, Zuzana; Kocks, Jan Willem H; Tsiligianni, Ioanna G
2014-08-01
Current guidelines recommend chronic obstructive pulmonary disease (COPD) management based on symptoms or health status assessment and lung function parameters. However, COPD is a complex and heterogeneous disease that needs an individualized approach for proper disease management. A structured consultation including health status assessment tools, such as the Clinical COPD Questionnaire and the COPD Assessment Test should improve the quality of the consultation, providing more information than symptoms alone. Both questionnaires are designed to provide the clinician information enabling a more personalized disease approach and subsequent management. Although both Clinical COPD Questionnaire and COPD Assessment Test have good discriminate properties, their use as prognostic markers of severity and their ability to modify disease management has not yet been fully established. New studies are needed to further determine their value on several disease outcomes.
COPD and exercise: does it make a difference?
Burtin, Chris; De Boever, Patrick; Langer, Daniël; Vogiatzis, Ioannis; Wouters, Emiel F.M.; Franssen, Frits M.E.
2016-01-01
Key points Physiological changes are observed following a structured exercise training programme in patients with COPD, without changes in resting lung function. Exercise training is the cornerstone of a comprehensive pulmonary rehabilitation programme in patients with COPD. Most comorbidities in patients referred for pulmonary rehabilitation remain undiagnosed and untreated. After careful screening, it is safe for COPD patients with comorbidities to obtain significant and clinically relevant improvements in functional exercise capacity and health status after an exercise-based pulmonary rehabilitation programme. Educational aims To inform readers of the positive effects of exercise-based pulmonary rehabilitation in patients with COPD, even with comorbid conditions. To inform readers of the importance of physical activity in patients with COPD. Exercise training is widely regarded as the cornerstone of pulmonary rehabilitation in patients with chronic obstructive pulmonary disease (COPD). Indeed, exercise training has been identified as the best available means of improving muscle function and exercise tolerance in patients with COPD. So, exercise training truly makes a difference in the life of patients with COPD. In this review, an overview is provided on the history of exercise training (as standalone intervention or as part of a comprehensive pulmonary rehabilitation programme), exercise training in comorbid patients with COPD, and the impact of physical activity counselling in a clean air environment. PMID:27408645
Hassani, Hamid; Golbabaei, Farideh; Ghahri, Asghar; Hosseini, Mostafa; Shirkhanloo, Hamid; Dinari, Behnam; Eskandari, Davood; Fallahi, Majid
2012-01-01
The objectives of this study were to evaluate manganese (Mn)-containing welding fumes' exposure, assess urinary Mn as a biomarker for Mn exposure and investigate the correlation of Mn in air, total fumes and urinary Mn with pulmonary function indices in 118 welders and 37 unexposed controls from two regions in Iran, Assaluyeh and Borujen. Air samples were collected on mixed cellulose ester membrane filters in personal air samplers and then analyzed using inductively coupled plasma atomic emission spectroscopy (ICP-AES) (NIOSH Method 7300). For all participants, urine samples were collected during the entire work shift, and Mn in urine was determined by graphite furnace atomic absorption spectroscopy according to NIOSH Method 8310. Spirometric measurements were also done for participants. The maximum exposures to airborne Mn and total fumes were 0.304 ± 0.256 mg/m(3) and 21.52 ± 9.40 mg/m(3), respectively. The urine Mn levels in the various groups ranged between 0.77 to 7.58 μg/l. The correlation between airborne Mn and urinary Mn was significant for total whole participants. Some values of spirometric indices were statistically lower in welders rather than controls. Our results indicate that many welders have been exposed to higher concentrations of Mn-containing welding fumes. Urinary Mn can be used as a biomarker for Mn exposure. There were weak inverse correlations between Mn-containing welding fumes and pulmonary function indices, and the inverse correlation between urinary Mn with forced vital capacities (FVC) and forced expiratory volume in 1 s (FEV1) was significant.
Bedzra, Edo K S; Dardas, Todd F; Cheng, Richard K; Pal, Jay D; Mahr, Claudius; Smith, Jason W; Shively, Kent; Masri, S Carolina; Levy, Wayne C; Mokadam, Nahush A
2017-12-01
To investigate the effect of pulmonary function testing on outcomes after continuous flow left ventricular assist device implantation. A total of 263 and 239 patients, respectively, had tests of forced expiratory volume in 1 second and diffusing capacity of the lungs for carbon monoxide preoperatively for left ventricular assist device implantations between July 2005 and September 2015. Kaplan-Meier analysis and multivariable Cox regressions were performed to evaluate mortality. Patients were analyzed in a single cohort and across 5 groups. Postoperative intensive care unit and hospital lengths of stay were evaluated with negative binomial regressions. There is no association of forced expiratory volume in 1 second and diffusing capacity of the lungs for carbon monoxide with survival and no difference in mortality at 1 and 3 years between the groups (log rank P = .841 and .713, respectively). Greater values in either parameter were associated with decreased hospital lengths of stay. Only diffusing capacity of the lungs for carbon monoxide was associated with increased intensive care unit length of stay in the group analysis (P = .001). Ventilator times, postoperative pneumonia, reintubation, and tracheostomy rates were similar across the groups. Forced expiratory volume in 1 second and diffusing capacity of the lungs for carbon monoxide are not associated with operative or long-term mortality in patients undergoing continuous flow left ventricular assist device implantation. These findings suggest that these abnormal pulmonary function tests alone should not preclude mechanical circulatory support candidacy. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Pre-operative optimisation of lung function
Azhar, Naheed
2015-01-01
The anaesthetic management of patients with pre-existing pulmonary disease is a challenging task. It is associated with increased morbidity in the form of post-operative pulmonary complications. Pre-operative optimisation of lung function helps in reducing these complications. Patients are advised to stop smoking for a period of 4–6 weeks. This reduces airway reactivity, improves mucociliary function and decreases carboxy-haemoglobin. The widely used incentive spirometry may be useful only when combined with other respiratory muscle exercises. Volume-based inspiratory devices have the best results. Pharmacotherapy of asthma and chronic obstructive pulmonary disease must be optimised before considering the patient for elective surgery. Beta 2 agonists, inhaled corticosteroids and systemic corticosteroids, are the main drugs used for this and several drugs play an adjunctive role in medical therapy. A graded approach has been suggested to manage these patients for elective surgery with an aim to achieve optimal pulmonary function. PMID:26556913
Pulmonary function evaluation during and following Skylab space flights
NASA Technical Reports Server (NTRS)
Sawin, C. F.; Nicogossian, A. E.; Schachter, A. P.; Rummel, J. A.; Michel, E. L.
1974-01-01
Previous experience during the Apollo postflight exercise testing indicated no major changes in pulmonary function. Although pulmonary function has been studied in detail following exposure to hypoxic and hyperoxic environments, few studies have dealt with normoxic environments at reduced total pressure as encountered during the Skylab missions. Forced vital capacity was measured during the preflight and postflight periods of the Skylab 2 mission. Initial in-flight measurements of vital capacity were obtained during the last two weeks of the second manned mission (Skylab 3). Comprehensive pulmonary function screening was accomplished during the Skylab 4 mission. The primary measurements made during Skylab 4 testing included residual volume determination, closing volume, vital capacity, and forced vital capacity and its derivatives. In addition, comprehensive in-flight vital capacity measurements were made during the Skylab 4 mission. Vital capacity was decreased slightly during flight in all Skylab 4 crewmen. No major preflight to postflight changes were observed in the other parameters.
Arjomandi, Mehrdad; Haight, Thaddeus; Redberg, Rita; Gold, Warren M
2009-06-01
To determine whether the flight attendants who were exposed to secondhand tobacco smoke in the aircraft cabin have abnormal pulmonary function. We administered questionnaires and performed pulmonary function testing in 61 never-smoking female flight attendants who worked in active air crews before the smoking ban on commercial aircraft (preban). Although the preban flight attendants had normal FVC, FEV1, and FEV1/FVC ratio, they had significantly decreased flow at mid- and low-lung volumes, curvilinear flow-volume curves, and evidence of air trapping. Furthermore, the flight attendants had significantly decreased diffusing capacity (77.5% +/- 11.2% predicted normal) with 51% having a diffusing capacity below their 95% normal prediction limit. This cohort of healthy never-smoking flight attendants who were exposed to secondhand tobacco smoke in the aircraft cabin showed pulmonary function abnormalities suggestive of airway obstruction and impaired diffusion.
The Critical Role of Pulmonary Arterial Compliance in Pulmonary Hypertension
Prins, Kurt W.; Pritzker, Marc R.; Scandurra, John; Volmers, Karl; Weir, E. Kenneth
2016-01-01
The normal pulmonary circulation is a low-pressure, high-compliance system. Pulmonary arterial compliance decreases in the presence of pulmonary hypertension because of increased extracellular matrix/collagen deposition in the pulmonary arteries. Loss of pulmonary arterial compliance has been consistently shown to be a predictor of increased mortality in patients with pulmonary hypertension, even more so than pulmonary vascular resistance in some studies. Decreased pulmonary arterial compliance causes premature reflection of waves from the distal pulmonary vasculature, leading to increased pulsatile right ventricular afterload and eventually right ventricular failure. Evidence suggests that decreased pulmonary arterial compliance is a cause rather than a consequence of distal small vessel proliferative vasculopathy. Pulmonary arterial compliance decreases early in the disease process even when pulmonary artery pressure and pulmonary vascular resistance are normal, potentially enabling early diagnosis of pulmonary vascular disease, especially in high-risk populations. With the recognition of the prognostic importance of pulmonary arterial compliance, its impact on right ventricular function, and its contributory role in the development and progression of distal small-vessel proliferative vasculopathy, pulmonary arterial compliance is an attractive target for the treatment of pulmonary hypertension. PMID:26848601
Diseases of Pulmonary Surfactant Homeostasis
Whitsett, Jeffrey A.; Wert, Susan E.; Weaver, Timothy E.
2015-01-01
Advances in physiology and biochemistry have provided fundamental insights into the role of pulmonary surfactant in the pathogenesis and treatment of preterm infants with respiratory distress syndrome. Identification of the surfactant proteins, lipid transporters, and transcriptional networks regulating their expression has provided the tools and insights needed to discern the molecular and cellular processes regulating the production and function of pulmonary surfactant prior to and after birth. Mutations in genes regulating surfactant homeostasis have been associated with severe lung disease in neonates and older infants. Biophysical and transgenic mouse models have provided insight into the mechanisms underlying surfactant protein and alveolar homeostasis. These studies have provided the framework for understanding the structure and function of pulmonary surfactant, which has informed understanding of the pathogenesis of diverse pulmonary disorders previously considered idiopathic. This review considers the pulmonary surfactant system and the genetic causes of acute and chronic lung disease caused by disruption of alveolar homeostasis. PMID:25621661
Drazner, Mark H; Velez-Martinez, Mariella; Ayers, Colby R; Reimold, Sharon C; Thibodeau, Jennifer T; Mishkin, Joseph D; Mammen, Pradeep P A; Markham, David W; Patel, Chetan B
2013-03-01
Although right atrial pressure (RAP) and pulmonary capillary wedge pressure (PCWP) are correlated in heart failure, in a sizeable minority of patients, the RAP and PCWP are not tightly coupled. The basis of this variability in the RAP/PCWP ratio, and whether it conveys prognostic value, is not known. We analyzed the Evaluation Study of Congestive Heart Failure and Pulmonary Artery Catheterization Effectiveness (ESCAPE) trial database. Baseline characteristics, including echocardiographic assessment of right ventricular (RV) structure and function, and invasively measured hemodynamic parameters, were compared among tertiles of the RAP/PCWP ratio. Multivariable Cox proportional hazard models assessed the association of RAP/PCWP ratio with the primary ESCAPE outcome (6-month death or hospitalization [days]) adjusting for systolic blood pressure, blood urea nitrogen, 6-minute walk distance, and PCWP. The RAP/PCWP tertiles were 0.27 to 0.4 (tertile 1); 0.41 to 0.615 (tertile 2), and 0.62 to 1.21 (tertile 3). Increasing RAP/PCWP was associated with increasing median right atrial area (23, 26, 29 cm2, respectively; P<0.005), RV area in diastole (21, 27, 27 cm2, respectively; P<0.005), and pulmonary vascular resistance (2.4, 2.9, 3.6 woods units, respectively; P=0.003), and lower RV stroke work index (8.6, 8.4, 5.5 g·m/m2 per beat, respectively; P<0.001). RAP/PCWP ratio was associated with death or hospitalization within 6 months (hazard ratio, 1.16 [1, 1.4]; P<0.05). Increased RAP/PCWP ratio was associated with higher pulmonary vascular resistance, reduced RV function (manifest as a larger right atrium and ventricle and lower RV stroke work index), and an increased risk of adverse outcomes in patients with advanced heart failure.
Schmitt, Todd L; Munns, Suzanne; Adams, Lance; Hicks, James
2013-09-01
This study utilized computed spirometry to compare the pulmonary function of two stranded olive ridley sea turtles (Lepidochelys olivacea) presenting with a positive buoyancy disorder with two healthy captive olive ridley sea turtles held in a large public aquarium. Pulmonary function test (PFT) measurements demonstrated that the metabolic cost of breathing was much greater for animals admitted with positive buoyancy than for the normal sea turtles. Positively buoyant turtles had higher tidal volumes and significantly lower breathing-frequency patterns with significantly higher expiration rates, typical of gasp-type breathing. The resulting higher energetic cost of breathing in the diseased turtles may have a significant impact on their long-term survival. The findings represent a method for clinical respiratory function analysis for an individual animal to assist with diagnosis, therapy, and prognosis. This is the first study, to our knowledge, to evaluate objectively sea turtles presenting with positive buoyancy and respiratory disease using pulmonary function tests.
Ambient polycyclic aromatic hydrocarbons and pulmonary function in children
Padula, Amy M.; Balmes, John R.; Eisen, Ellen A.; Mann, Jennifer; Noth, Elizabeth M.; Lurmann, Frederick W.; Pratt, Boriana; Tager, Ira B.; Nadeau, Kari; Hammond, S. Katharine
2014-01-01
Few studies have examined the relationship between ambient polycyclic aromatic hydrocarbons (PAHs) and pulmonary function in children. Major sources include vehicular emissions, home heating, wildland fires, agricultural burning, and power plants. PAHs are an important component of fine particulate matter that has been linked to respiratory health. This cross-sectional study examines the relationship between estimated individual exposures to the sum of PAHs with 4, 5, or 6 rings (PAH456) and pulmonary function tests (forced expiratory volume in one second (FEV1) and forced expiratory flow between 25% and 75% of vital capacity) in asthmatic and non-asthmatic children. We applied land-use regression to estimate individual exposures to ambient PAHs for averaging periods ranging from 1 week to 1 year. We used linear regression to estimate the relationship between exposure to PAH456 with pre- and postbronchodilator pulmonary function tests in children in Fresno, California (N =297). Among non-asthmatics, there was a statistically significant association between PAH456 during the previous 3 months, 6 months, and 1 year and postbronchodilator FEV1. The magnitude of the association increased with the length of the averaging period ranging from 60 to 110 ml decrease in FEV1 for each 1 ng/m3 increase in PAH456. There were no associations with PAH456 observed among asthmatic children. We identified an association between annual PAHs and chronic pulmonary function in children without asthma. Additional studies are needed to further explore the association between exposure to PAHs and pulmonary function, especially with regard to differential effects between asthmatic and non-asthmatic children. PMID:24938508
Araz, Omer; Aydin, Mehmet Dumlu; Gundogdu, Betul; Altas, Ender; Cakir, Murteza; Calikoglu, Cagatay; Atalay, Canan; Gundogdu, Cemal
2015-01-01
Pulmonary arteries are mainly innervated by sympathetic vasoconstrictor and parasympathetic vasodilatory fibers. We examined whether there is a relationship between the neuron densities of hilar parasympathetic ganglia and pulmonary vasospasm in subarachnoid hemorrhage (SAH). Twenty-four rabbits were divided into two groups: control (n=8) and SAH (n=16). The animals were observed for 20 days following experimental SAH. The number of hilar parasympathetic ganglia and their neuron densities were determined. Proportion of pulmonary artery ring surface to lumen surface values was accepted as vasospasm index (VSI). Neuron densities of the hilar ganglia and VSI values were compared statistically. Animals in the SAH group experienced either mild (n=6) or severe (n=10) pulmonary artery vasospasm. In the control group, the mean VSI of pulmonary arteries was 0.777±0.048 and the hilar ganglion neuron density was estimated as 12.100±2.010/mm < sup > 3 < /sup > . In SAH animals with mild vasospasm, VSI=1.148±0.090 and neuron density was estimated as 10.110±1.430/mm < sup > 3 < /sup > ; in animals with severe vasospasm, VSI=1.500±0.120 and neuron density was estimated as 7.340±990/mm < sup > 3 < /sup > . There was an inverse correlation between quantity and neuron density of hilar ganglia and vasospasm index value. The low numbers and low density of hilar parasympathetic ganglia may be responsible for the more severe artery vasospasm in SAH.
Doyle, Todd; Palmer, Scott; Johnson, Julie; Babyak, Michael A.; Smith, Patrick; Mabe, Stephanie; Welty-Wolf, Karen; Martinu, Tereza; Blumenthal, James A.
2014-01-01
Objectives To examine the association of anxiety and depression with pulmonary-specific symptoms of Chronic Obstructive Pulmonary Disease (COPD), and to determine the extent to which disease severity and functional capacity modify this association. Method Patients (N = 162) enrolled in the INSPIRE-II study, an ongoing randomized, clinical trial of COPD patients and their caregivers who received either telephone-based coping skills training or education and symptom monitoring. Patients completed a psychosocial test battery including: Brief Fatigue Inventory, St. George’s Respiratory Questionnaire, UCSD Shortness of Breath Questionnaire, State-Trait Anxiety Inventory, and Beck Depression Inventory. Measures of disease severity and functional capacity (i.e., FEV1 and six-minute walk test) were also obtained. Results After covariate adjustment, higher anxiety and depression levels were associated with greater fatigue levels (ps < .001, ΔR2 = 0.16 and 0.29, respectively), shortness of breath (ps < .001, ΔR2 = 0.12 and 0.10), and frequency of COPD symptoms (ps < .001, ΔR2 = 0.11 and 0.13). In addition, functional capacity was a moderator of anxiety and pulmonary-specific COPD symptoms. The association between anxiety and shortness of breath (p = 0.009) and frequency of COPD symptoms (p = 0.02) was greater among patients with lower functional capacity. Conclusions Anxiety and depression were associated with higher levels of fatigue, shortness of breath, and frequency of COPD symptoms. It is important for clinicians to be aware of the presence of anxiety and depression in COPD patients, which appears to correlate with pulmonary-specific COPD symptoms, especially in patients with lower functional capacity. Prospective design studies are needed to elucidate the causal relationships between anxiety and depression and pulmonary-specific symptoms in COPD patients. PMID:23977821
Amin, Reshma; Dupuis, Annie; Aaron, Shawn D; Ratjen, Felix
2010-01-01
The relevance of Aspergillus fumigatus in patients with cystic fibrosis (CF) not affected by allergic bronchopulmonary aspergillosis is unclear. Our aim was to determine the effect of persistent infection with A fumigatus on pulmonary exacerbations and lung function in children with CF. This was a retrospective cohort study of patients with CF followed at The Hospital for Sick Children from 1999 to 2006. Persistent A fumigatus infection was defined as the presence of two or more positive sputum or bronchoalveolar cultures for A fumigatus in a given year. The primary outcome measure was the annual number of hospitalizations for pulmonary exacerbations. Two hundred thirty patients with CF were included in the analysis. The FEV(1) of patients persistently infected with A fumigatus was 3.61% (P< or =.0001) lower during the study period compared with uninfected patients. There was a significant interaction between A fumigatus and Pseudomonas aeruginosa on lung function (P=.0006). Patients not infected with either organism had the highest pulmonary function. Persistent A fumigatus infection (relative risk [RR]=1.94, P=.0002) and CF-related diabetes (RR=1.64, P=.028) were associated with an increased risk of pulmonary exacerbations requiring hospitalization, whereas there was no increased risk of pulmonary exacerbations among patients with allergic bronchopulmonary aspergillosis (RR=1.02, P=.94). When adjusted for baseline pulmonary function, none of these variables were associated with a significantly increased risk of pulmonary exacerbations, with only chronic A fumigatus infection trending toward significance (RR=1.40, P=.065). Persistent A fumigatus infection is an independent risk factor for hospital admissions in patients with CF.
Chowdhury, Shahryar M.; Hijazi, Ziyad M.; Rhodes, John F.; Kar, Saibal; Makkar, Raj; Mullen, Michael; Cao, Qi-Ling; Mandinov, Lazar; Buckley, Jason; Pietris, Nicholas P.; Shirali, Girish S.
2015-01-01
Background Patients with free pulmonary regurgitation or mixed pulmonary stenosis and regurgitation and severely dilated right ventricles (RV) show little improvement in ventricular function after pulmonary valve replacement when assessed by traditional echocardiographic markers. We evaluated changes in right and left ventricular (LV) function using speckle tracking echocardiography in patients after SAPIEN transcatheter pulmonary valve (TPV) placement. Methods Echocardiograms were evaluated at baseline, discharge, 1 and 6 months after TPV placement in 24 patients from 4 centers. Speckle tracking measures of function included peak longitudinal strain, strain rate, and early diastolic strain rate. RV fractional area change, tricuspid annular plane systolic excursion, and left ventricular LV ejection fraction were assessed. Routine Doppler and tissue Doppler velocities were measured. Results At baseline, all patients demonstrated moderate to severe pulmonary regurgitation; this improved following TPV placement. No significant changes were detected in conventional measures of RV or LV function at 6 months. RV longitudinal strain (−16.9% vs. −19.6%, P < 0.01), strain rate (−0.87 s−1 vs. −1.16 s−1, P = 0.01), and LV longitudinal strain (−16.2% vs. −18.2%, P = 0.01) improved between baseline and 6 month follow-up. RV early diastolic strain rate, LV longitudinal strain rate and early diastolic strain rate showed no change. Conclusion Improvements in RV longitudinal strain, strain rate, and LV longitudinal strain are seen at 6 months post-TPV. Diastolic function does not appear to change at 6 months. Speckle tracking echocardiography may be more sensitive than traditional measures in detecting changes in systolic function after TPV implantation. (Echocardiography 2015;32:461–469) PMID:25047063
Isolated Human Pulmonary Artery Structure and Function Pre- and Post-Cardiopulmonary Bypass Surgery.
Dora, Kim A; Stanley, Christopher P; Al Jaaly, Emad; Fiorentino, Francesca; Ascione, Raimondo; Reeves, Barnaby C; Angelini, Gianni D
2016-02-23
Pulmonary dysfunction is a known complication after cardiac surgery using cardiopulmonary bypass, ranging from subclinical functional changes to prolonged postoperative ventilation, acute lung injury, and acute respiratory distress syndrome. Whether human pulmonary arterial function is compromised is unknown. The aim of the present study was to compare the structure and function of isolated and cannulated human pulmonary arteries obtained from lung biopsies after the chest was opened (pre-cardiopulmonary bypass) to those obtained at the end of cardiopulmonary bypass (post-cardiopulmonary bypass) from patients undergoing coronary artery bypass graft surgery. Pre- and post-cardiopulmonary bypass lung biopsies were received from 12 patients undergoing elective surgery. Intralobular small arteries were dissected, cannulated, pressurized, and imaged using confocal microscopy. Functionally, the thromboxane mimetic U46619 produced concentration-dependent vasoconstriction in 100% and 75% of pre- and post-cardiopulmonary bypass arteries, respectively. The endothelium-dependent agonist bradykinin stimulated vasodilation in 45% and 33% of arteries pre- and post-cardiopulmonary bypass, respectively. Structurally, in most arteries smooth muscle cells aligned circumferentially; live cell viability revealed that although 100% of smooth muscle and 90% of endothelial cells from pre-cardiopulmonary bypass biopsies had intact membranes and were considered viable, only 60% and 58%, respectively, were viable from post-cardiopulmonary bypass biopsies. We successfully investigated isolated pulmonary artery structure and function in fresh lung biopsies from patients undergoing heart surgery. Pulmonary artery contractile tone and endothelium-dependent dilation were significantly reduced in post-cardiopulmonary bypass biopsies. The decreased functional responses were associated with reduced cell viability. URL: http://www.isrctn.com/ISRCTN34428459. Unique identifier: ISRCTN 34428459. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
NASA Technical Reports Server (NTRS)
Clark, J. M.; Gelfand, R.; Flores, N. D.; Lambertsen, C. J.; Pisarello, J. B.
1987-01-01
Oxygen effects on pulmonary function were measured in normal, resting men who breathed oxygen continuously at 3.0, 2.5, 2.0, and 1.5 ATA to predefined limits of CNS, cardiac, or pulmonary tolerance. Rates of pulmonary symptom intensification and decrease in vital capacity (VC) increased progressively with elevation of inspired oxygen pressure. Although VC decrements occurred concurrently with symptoms, the lung volume changes became prominent when symptoms were still mild. The observed effects were consistent with the interpretation that small airway function is impaired more selectively by oxygen exposure at 3.0 and 2.5 ATA than by exposure at 2.0 and 1.5 ATA. Despite similar VC changes after oxygen exposure at 2.0 ATA for nearly 10 hr and exposure at 1.5 ATA for almost 18 hr, the 2.0 ATA exposure caused greater impairment of pulmonary function and required a longer recovery period.
2016-01-01
Influenza vaccination is an effective strategy to reduce morbidity and mortality, particularly for those who have decreased lung functions. This study was to identify the factors that affect vaccination coverage according to the results of pulmonary function tests depending on the age. In this cross-sectional study, data were obtained from 3,224 adults over the age of 40 who participated in the fifth National Health and Nutrition Examination Survey and underwent pulmonary function testing in 2012. To identify the factors that affect vaccination rate, logistic regression analysis was conducted after dividing the subjects into two groups based on the age of 65. Influenza vaccination coverage of the entire subjects was 45.2%, and 76.8% for those aged 65 and over. The group with abnormal pulmonary function had a higher vaccination rate than the normal group, but any pulmonary dysfunction or history of COPD did not affect the vaccination coverage in the multivariate analysis. The subjects who were 40-64 years-old had higher vaccination coverage when they were less educated or with restricted activity level, received health screenings, and had chronic diseases. Those aged 65 and over had significantly higher vaccination coverage only when they received regular health screenings. Any pulmonary dysfunction or having COPD showed no significant correlation with the vaccination coverage in the Korean adult population. PMID:27134491
Cleva, Roberto de; Assumpção, Marianna Siqueira de; Sasaya, Flavia; Chaves, Natalia Zuniaga; Santo, Marco Aurelio; Fló, Claudia; Lunardi, Adriana C; Jacob Filho, Wilson
2014-07-01
Patients undergoing abdominal surgery are at risk for pulmonary complications. The principal cause of postoperative pulmonary complications is a significant reduction in pulmonary volumes (FEV1 and FVC) to approximately 65-70% of the predicted value. Another frequent occurrence after abdominal surgery is increased intra-abdominal pressure. The aim of this study was to correlate changes in pulmonary volumes with the values of intra-abdominal pressure after abdominal surgery, according to the surgical incision in the abdomen (superior or inferior). We prospectively evaluated 60 patients who underwent elective open abdominal surgery with a surgical time greater than 240 minutes. Patients were evaluated before surgery and on the 3rd postoperative day. Spirometry was assessed by maximal respiratory maneuvers and flow-volume curves. Intra-abdominal pressure was measured in the postoperative period using the bladder technique. The mean age of the patients was 56 ± 13 years, and 41.6% 25 were female; 50 patients (83.3%) had malignant disease. The patients were divided into two groups according to the surgical incision (superior or inferior). The lung volumes in the preoperative period showed no abnormalities. After surgery, there was a significant reduction in both FEV1 (1.6 ± 0.6 L) and FVC (2.0 ± 0.7 L) with maintenance of FEV1/FVC of 0.8 ± 0.2 in both groups. The maximum intra-abdominal pressure values were similar (p=0.59) for the two groups. There was no association between pulmonary volumes and intra-abdominal pressure measured in any of the groups analyzed. Our results show that superior and inferior abdominal surgery determines hypoventilation, unrelated to increased intra-abdominal pressure. Patients at high risk of pulmonary complications should receive respiratory care even if undergoing inferior abdominal surgery.
Zhang, Chen; Li, Qiangqiang; Zhu, Yan; Gu, Hong
2014-06-10
To explore the risk and protective factors for pulmonary hypertensive crisis (PHC) in patients with idiopathic pulmonary arterial hypertension (IPAH). A retrospective study was performed for 65 patients with a diagnosis of IPAH between January 2010 and December 2013. According to clinical manifestations, they were divided into two groups of susceptibility and non-susceptibility to PHC. Clinical and hemodynamic parameters were analyzed in univariate and multivariate manners. Among them, there were 32 males and 33 females with a mean age of (14.4 ± 12.3) (10/12-47.3) years. Twenty-three patients had typical manifestations of PHC and 18 of them were induced by exercises.Univariate analysis revealed that the proportion of patients with World Health Organization (WHO) functional class III-IV in PHC-susceptible group was significantly higher than PHC-nonsusceptible group (60.9% vs 23.8%, P = 0.003) while the percentage of patent foramen ovale in PHC-susceptible group was significantly lower than PHC-nonsusceptible group (8.7% vs 45.2%, P = 0.003).In patients with WHO functional classI-II, hemodynamic variables including the decline of pulmonary arterial pressure and positive rate in vasoreactivity testing in PHC-susceptible group were significantly higher than PHC-nonsusceptible group.In patients with WHO functional class III-IV, baseline pulmonary arterial pressure and mean right atrial pressure in PHC-susceptible group were significantly higher than those in PHC-nonsusceptible group. Multivariate Logistic regression analysis revealed that, for those with WHO functional class III-IV (OR = 23.45, 95%CI: 2.85-193.09) and the decline of systolic pulmonary arterial pressure in vasoreactivity testing (OR = 1.12, 95%CI: 1.04-1.22) were independent risk factors for PHC in IPAH patients while patent foramen ovale (OR = 0.01, 95%CI: 0.00-0.52) was a protective factor. PHC in IPAH patients is correlated with WHO functional class, pulmonary vascular reactivity, baseline pulmonary arterial pressure and patent foramen ovale. And exercise is the most common stimulus to PHC.
High-Resolution Time-Frequency Spectrum-Based Lung Function Test from a Smartphone Microphone
Thap, Tharoeun; Chung, Heewon; Jeong, Changwon; Hwang, Ki-Eun; Kim, Hak-Ryul; Yoon, Kwon-Ha; Lee, Jinseok
2016-01-01
In this paper, a smartphone-based lung function test, developed to estimate lung function parameters using a high-resolution time-frequency spectrum from a smartphone built-in microphone is presented. A method of estimation of the forced expiratory volume in 1 s divided by forced vital capacity (FEV1/FVC) based on the variable frequency complex demodulation method (VFCDM) is first proposed. We evaluated our proposed method on 26 subjects, including 13 healthy subjects and 13 chronic obstructive pulmonary disease (COPD) patients, by comparing with the parameters clinically obtained from pulmonary function tests (PFTs). For the healthy subjects, we found that an absolute error (AE) and a root mean squared error (RMSE) of the FEV1/FVC ratio were 4.49% ± 3.38% and 5.54%, respectively. For the COPD patients, we found that AE and RMSE from COPD patients were 10.30% ± 10.59% and 14.48%, respectively. For both groups, we compared the results using the continuous wavelet transform (CWT) and short-time Fourier transform (STFT), and found that VFCDM was superior to CWT and STFT. Further, to estimate other parameters, including forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), and peak expiratory flow (PEF), regression analysis was conducted to establish a linear transformation. However, the parameters FVC, FEV1, and PEF had correlation factor r values of 0.323, 0.275, and −0.257, respectively, while FEV1/FVC had an r value of 0.814. The results obtained suggest that only the FEV1/FVC ratio can be accurately estimated from a smartphone built-in microphone. The other parameters, including FVC, FEV1, and PEF, were subjective and dependent on the subject’s familiarization with the test and performance of forced exhalation toward the microphone. PMID:27548164
Maniatis, Nikolaos A.; Chernaya, Olga; Shinin, Vasily; Minshall, Richard D.
2012-01-01
The primary function of the mammalian lung is to facilitate diffusion of oxygen to venous blood and to ventilate carbon dioxide produced by catabolic reactions within cells. However, it is also responsible for a variety of other important functions, including host defense and production of vasoactive agents to regulate not only systemic blood pressure, but also water, electrolyte and acid-base balance. Caveolin-1 is highly expressed in the majority of cell types in the lung, including epithelial, endothelial, smooth muscle, connective tissue cells, and alveolar macrophages. Deletion of caveolin-1 in these cells results in major functional aberrations, suggesting that caveolin-1 may be crucial to lung homeostasis and development. Furthermore, generation of mutant mice that under-express caveolin-1 results in severe functional distortion with phenotypes covering practically the entire spectrum of known lung diseases, including pulmonary hypertension, fibrosis, increased endothelial permeability, and immune defects. In this Chapter, we outline the current state of knowledge regarding caveolin-1-dependent regulation of pulmonary cell functions and discuss recent research findings on the role of caveolin-1 in various pulmonary disease states, including obstructive and fibrotic pulmonary vascular and inflammatory diseases. PMID:22411320
Ormeño Julca, Alexis Jose; Alvarez Murillo, Carlos Melchor; Amoretti Alvino, Pedro Miguel; Florian Florian, Angel Aladino; Castro Johanson, Rosa Aurora; Celi Perez, Maria Danisa; Huamán Prado, Olga Rocío
2017-01-01
The hepatopulmonary syndrome (HPS) and portopulmonary hypertension (PPHN) are distinct pulmonary vascular complications of portal hypertension (PHT) and are associated with increased morbidity and mortality. To describe the clinical and laboratory characteristics of patients with pulmonary hypertension and pulmonary vascular complications hospitalized at the Instituto Nacional de Salud del Niño. We included patients with HTP hospitalized from January 2012 to June 2013 and that during its evolution progressed with SHP or HTPP. For analysis, they were divided into a first group of patients with liver cirrhosis and a second group with extrahepatic portal vein obstruction. Of 22 patients with HPT 45.5% were male and the age range was between 1 month and 17 years. The etiology in the group of cirrhosis (n=14) was: autoimmune hepatitis (35.7%), cryptogenic cirrhosis (35.7%), inborn error of metabolism (14.3%), chronic viral hepatitis C (7.15%) virus and atresia extra-hepatic bile ducts (7.15%). Pulmonary vascular complications more frequently occurred in patients with liver cirrhosis (1 case of HPS and a case of PPHTN). They most often dyspnea, asthenia, edema, malnutrition, ascites, hypersplenism and gastrointestinal bleeding from esophageal varices was found. Also, they had elevated ALT values, alkaline phosphatase and serum albumin values decreased. In children with pulmonary hypertension, pulmonary vascular complications are rare. In the evaluation of these patients pulse oximetry should be included to detect hypoxemia and ubsequently a Doppler echocardiography and contrast echocardiography necessary. Dueto the finding of systolic pulmonary hypertension it is necessary to perform right heart catheterization.
Wexels, Fredrik; Dahl, Ola E; Pripp, Are H; Seljeflot, Ingebjørg; Borris, Lars C; Haslund, Anniken; Gudmundsen, Tor E; Lauritzen, Trine; Lassen, Michael R
2014-07-01
We have recently reported that increased levels of urine prothrombin fragment 1+2 reflected radiologically verified deep vein thrombosis. In this study we evaluated whether urine prothrombin fragment 1+2 was associated with pulmonary embolism in non-selected patients. Patients with clinical suspected pulmonary embolism were interviewed on comorbidities and medications. Urine was collected from each patient before radiological examination and snap frozen until analysed on urine prothrombin fragment 1+2 with an ELISA kit. Imaging of the pulmonary arteries were conducted with contrast enhanced computer tomography. Pulmonary embolism was diagnosed in 44/197 patients. Non-significantly higher urine prothrombin fragment 1+2 levels were found in non-selected patients with pulmonary embolism vs. those without (p=0.324). Significantly higher urine prothrombin fragment 1+2 levels were found in the pulmonary embolism positive patients without comorbidities (n=13) compared to the control group (n=28) (p=0.009). The calculated sensitivity, specificity and negative predictive value using the lowest detectable urine prothrombin fragment 1+2 level was 82%, 34% and 87%, respectively. There was no significant urine prothrombin fragment 1+2 level difference in patients with and without pulmonary embolism. In non-comorbide pulmonary embolism positive patients the urine prothrombin fragment 1+2 levels were significantly higher compared to the control group. The negative predictive value found in this study indicates that uF1+2 has the potential to identify patients with a low risk of PE. Copyright © 2014 Elsevier Ltd. All rights reserved.
Chien, Kuang-Jen; Huang, Hurng-Wern; Huang, Ta-Cheng; Lee, Cheng-Liang; Weng, Ken-Pen; Lin, Chu-Chuan; Shieh, Po-Chuen; Wu, Ming-Ting; Hsieh, Kai-Sheng
2016-01-01
The aim of this study was to compare the usefulness of lung perfusion scintigraphy and echocardiogram in the evaluation of the branch pulmonary arteries stenosis in children with tetralogy of Fallot (TOF). From February 2006 to November 2008, 74 children (mean age 7.8 years, range 1–18 years) who underwent repair of TOF at ages from 10 months to 13 years were suspected to have unilateral or bilateral branch pulmonary artery stenosis. In all patients, cardiac angiography was performed to confirm the diagnosis of branch pulmonary artery stenosis. Lung perfusion scintigraphy and two-dimensional transthoracic echocardiography were performed in all patients to compare their abilities to diagnose branch pulmonary artery stenosis. Of the 74 patients, 51 cases were found to have branch pulmonary artery stenosis by cardiac angiography. There was agreement between the scintigraphic and angiographic findings in 44 (86%) patients and there were discrepancies in 11 (15%) patients. The positive predictive value of our lung perfusion scintigraphy in detecting the branch pulmonary artery stenosis was 92 %. The positive and negative likelihood ratios of lung perfusion scintigraphy were 4.96 and 0.17, respectively. There was conformity between the echocardiographic and angiographic findings in 40 (78%) patients with discrepancies in 16 (21%) patients. The positive predictive value of our echocardiography in detecting the branch pulmonary artery stenosis was 89%. The positive and negative likelihood ratios of echocardiography were 3.61 and 0.28, respectively. Lung perfusion scintigraphy is a valuable, non-invasive screening tool in the assessment of branch pulmonary artery stenosis in children after TOF.
Secondary Pulmonary Hypertension and Right-Sided Heart Failure at Presentation in Grave's Disease
Ganeshpure, Swapnil Panjabrao; Vaidya, Gaurang Nandkishor; Gattani, Vipul
2012-01-01
A young female presented with evidence of right-sided heart failure and was subsequently found to have significant pulmonary artery hypertension (PAH). Because of her normal left ventricular function and pulmonary capillary wedge pressure, the most probable site of etiology seemed to be the pulmonary vasculature. All the common possible secondary causes of PAH were ruled out, but during the investigations, she was found to have elevated thyroid function tests compatible with the diagnosis of Grave's disease. The treatment of Grave's disease, initially by medications and subsequently by radioiodine therapy, was associated with a significant reduction in the pulmonary artery systolic pressure. The purpose of this case report is to highlight one of the unusual and underdiagnosed presentations of Grave's disease. PMID:23198182
Imaging-based assessment of dyspnea in cigarette smokers
NASA Astrophysics Data System (ADS)
Galvin, Jeffrey R.; Chang, Paul J.; Schwartz, David A.; Hunninghake, Gary W.; Helmers, Richard; Mori, Masaki
1994-05-01
Patients with pulmonary fibrosis frequently smoke cigarettes. The cause of dyspnea in these patients is often complex because of the coexistence of multiple disease processes. We investigated 10 cigarette smokers with pulmonary fibrosis who were referred for evaluation of new onset or worsening dyspnea. Chest radiographs and pulmonary function tests were obtained in addition to high-resolution computed tomography (HRCT). In those patients with HRCT evidence of both diseases, spirometry and lung volumes were most often normal. Although plain films provided a reasonable assessment of fibrosis, they underestimated the severity of emphysema. Quantitation of both emphysema and fibrosis by HRCT was reproducible and correlated with key pulmonary function tests. Our findings indicate that the HRCT scan is a useful diagnostic test in patients with pulmonary fibrosis who are also cigarette smokers.
Linking microbiota and respiratory disease.
Hauptmann, Matthias; Schaible, Ulrich E
2016-11-01
An increasing body of evidence indicates the relevance of microbiota for pulmonary health and disease. Independent investigations recently demonstrated that the lung harbors a resident microbiota. Therefore, it is intriguing that a lung microbiota can shape pulmonary immunity and epithelial barrier functions. Here, we discuss the ways how the composition of the microbial community in the lung may influence pulmonary health and vice versa, factors that determine community composition. Prominent microbiota at other body sites such as the intestinal one may also contribute to pulmonary health and disease. However, it is difficult to discriminate between influences of lung vs. gut microbiota due to systemic mutuality between both communities. With focuses on asthma and respiratory infections, we discuss how microbiota of lung and gut can determine pulmonary immunity and barrier functions. © 2016 Federation of European Biochemical Societies.
Domingo, Enric; Aguilar, Rio; López-Meseguer, Manuel; Teixidó, Gisela; Vazquez, Manuel; Roman, Antonio
2009-01-01
Pulmonary arterial hypertension (PAH) is a rare fatal disease defined as a sustained elevation of pulmonary arterial pressure to more than 25 mmHg at rest, with a mean pulmonary-capillary wedge pressure and left ventricular enddiastolic pressure of less than 15 mmHg at rest. Histopathology of PAH is founded on structural modifications on the vascular wall of small pulmonary arteries characterized by thickening of all its layers. These changes, named as vascular remodelling, include vascular proliferation, fibrosis, and vessel obstruction. In clinical practice the diagnosis of PAH relies on measurements of pulmonary vascular pressure and cardiac output, and calculation of pulmonary vascular resistances. Direct evaluation of pulmonary vascular structure is not routinely performed in pulmonary hypertension since current imaging techniques are limited and since little is known about the relationship between structural changes and functional characteristics of the pulmonary vasculature. Intravascular ultrasound studies in patients with pulmonary hypertension have shown a thicker middle layer, increased wall-thickness ratio and diminished pulsatility than in control patients. Optical Coherence Tomography, a new high resolution imaging modality that has proven its superiority over intravascular ultrasound (IVUS) for the detection and characterization of coronary atherosclerotic plaque composition, may potentially be a useful technique for the in vivo study of the pulmonary arterial wall. In addition current progress in Echo Doppler technique will quantify right ventricular function with parameters independent of loading conditions and not requiring volumetric approximations of the complex geometry of the right ventricle. This would allow the in vivo study of right ventricular and pulmonary artery remodelling in PAH. PMID:19452037
Percutaneous Pulmonary Valve Placement
Prieto, Lourdes R.
2015-01-01
Patients with congenital heart disease and pulmonary valve disease need multiple procedures over their lifetimes to replace their pulmonary valves. Chronic pulmonary stenosis, regurgitation, or both have untoward effects on ventricular function and on the clinical status of these patients. To date, all right ventricle–pulmonary artery conduits have had relatively short lifespans. Percutaneous pulmonary valve implantation, although relatively new, will probably reduce the number of operative procedures that these patients will have to undergo over a lifetime. Refinement and further development of this procedure holds promise for the extension of this technology to other patient populations. PMID:26175629
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fukunaga, Satoki; Environmental Health Science Laboratory, Sumitomo Chemical Co., Ltd., 3-1-98 Kasugade-Naka, Konohana-ku, Osaka 554-8558; Kakehashi, Anna
To determine miRNAs and their predicted target proteins regulatory networks which are potentially involved in onset of pulmonary fibrosis in the bleomycin rat model, we conducted integrative miRNA microarray and iTRAQ-coupled LC-MS/MS proteomic analyses, and evaluated the significance of altered biological functions and pathways. We observed that alterations of miRNAs and proteins are associated with the early phase of bleomycin-induced pulmonary fibrosis, and identified potential target pairs by using ingenuity pathway analysis. Using the data set of these alterations, it was demonstrated that those miRNAs, in association with their predicted target proteins, are potentially involved in canonical pathways reflective ofmore » initial epithelial injury and fibrogenic processes, and biofunctions related to induction of cellular development, movement, growth, and proliferation. Prediction of activated functions suggested that lung cells acquire proliferative, migratory, and invasive capabilities, and resistance to cell death especially in the very early phase of bleomycin-induced pulmonary fibrosis. The present study will provide new insights for understanding the molecular pathogenesis of idiopathic pulmonary fibrosis. - Highlights: • We analyzed bleomycin-induced pulmonary fibrosis in the rat. • Integrative analyses of miRNA microarray and proteomics were conducted. • We determined the alterations of miRNAs and their potential target proteins. • The alterations may control biological functions and pathways in pulmonary fibrosis. • Our result may provide new insights of pulmonary fibrosis.« less
Molecular insights into the progression of crystalline silica-induced pulmonary toxicity in rats.
Sellamuthu, Rajendran; Umbright, Christina; Roberts, Jenny R; Cumpston, Amy; McKinney, Walter; Chen, Bean T; Frazer, David; Li, Shengqiao; Kashon, Michael; Joseph, Pius
2013-04-01
Identification of molecular target(s) and mechanism(s) of silica-induced pulmonary toxicity is important for the intervention and/or prevention of diseases associated with exposure to silica. Rats were exposed to crystalline silica by inhalation (15 mg m(-3), 6 h per day, 5 days) and global gene expression profile was determined in the lungs by microarray analysis at 1, 2, 4, 8 and 16 weeks following termination of silica exposure. The number of significantly differentially expressed genes (>1.5-fold change and <0.01 false discovery rate P-value) detected in the lungs during the post-exposure time intervals analyzed exhibited a steady increase in parallel with the progression of silica-induced pulmonary toxicity noticed in the rats. Quantitative real-time PCR analysis of a representative set of 10 genes confirmed the microarray findings. The number of biological functions, canonical pathways and molecular networks significantly affected by silica exposure, as identified by the bioinformatics analysis of the significantly differentially expressed genes detected during the post-exposure time intervals, also exhibited a steady increase similar to the silica-induced pulmonary toxicity. Genes involved in oxidative stress, inflammation, respiratory diseases, cancer, and tissue remodeling and fibrosis were significantly differentially expressed in the rat lungs; however, unresolved inflammation was the single most significant biological response to pulmonary exposure to silica. Excessive mucus production, as implicated by significant overexpression of the pendrin coding gene, SLC26A4, was identified as a potential novel mechanism for silica-induced pulmonary toxicity. Collectively, the findings of our study provided insights into the molecular mechanisms underlying the progression of crystalline silica-induced pulmonary toxicity in the rat. Published 2012. This article is a US Government work and is in the public domain in the USA. Published 2012. This article is a US Government work and is in the public domain in the USA.
Starck, J M; Weimer, I; Aupperle, H; Müller, K; Marschang, R E; Kiefer, I; Pees, M
2015-11-01
A qualitative and quantitative morphological study of the pulmonary exchange capacity of healthy and diseased Burmese pythons (Python molurus) was carried out in order to test the hypothesis that the high morphological excess capacity for oxygen exchange in the lungs of these snakes is one of the reasons why pathological processes extend throughout the lung parenchyma and impair major parts of the lungs before clinical signs of respiratory disease become apparent. Twenty-four Burmese pythons (12 healthy and 12 diseased) were included in the study. A stereology-based approach was used to quantify the lung parenchyma using computed tomography. Light microscopy was used to quantify tissue compartments and the respiratory exchange surface, and transmission electron microscopy was used to measure the thickness of the diffusion barrier. The morphological diffusion capacity for oxygen of the lungs and the anatomical diffusion factor were calculated. The calculated anatomical diffusion capacity was compared with published values for oxygen consumption of healthy snakes, and the degree to which the exchange capacity can be obstructed before normal physiological function is impaired was estimated. Heterogeneous pulmonary infections result in graded morphological transformations of pulmonary parenchyma involving lymphocyte migration into the connective tissue and thickening of the septal connective tissue, increasing thickness of the diffusion barrier and increasing transformation of the pulmonary epithelium into a columnar pseudostratified or stratified epithelium. The transformed epithelium developed by hyperplasia of ciliated cells arising from the tip of the faveolar septa and by hyperplasia of type II pneumocytes. These results support the idea that the lungs have a remarkable overcapacity for oxygen consumption and that the development of pulmonary disease continuously reduces the capacity for oxygen consumption. However, due to the overcapacity of the lungs, this reduction does not result in clinical signs and disease can progress unrecognized for an extended period. Copyright © 2015 Elsevier Ltd. All rights reserved.
Amsallem, Myriam; Sweatt, Andrew J; Aymami, Marie C; Kuznetsova, Tatiana; Selej, Mona; Lu, HongQuan; Mercier, Olaf; Fadel, Elie; Schnittger, Ingela; McConnell, Michael V; Rabinovitch, Marlene; Zamanian, Roham T; Haddad, Francois
2017-06-01
Right ventricular (RV) end-systolic dimensions provide information on both size and function. We investigated whether an internally scaled index of end-systolic dimension is incremental to well-validated prognostic scores in pulmonary arterial hypertension. From 2005 to 2014, 228 patients with pulmonary arterial hypertension were prospectively enrolled. RV end-systolic remodeling index (RVESRI) was defined by lateral length divided by septal height. The incremental values of RV free wall longitudinal strain and RVESRI to risk scores were determined. Mean age was 49±14 years, 78% were female, 33% had connective tissue disease, 52% were in New York Heart Association class ≥III, and mean pulmonary vascular resistance was 11.2±6.4 WU. RVESRI and right atrial area were strongly connected to the other right heart metrics. Three zones of adaptation (adapted, maladapted, and severely maladapted) were identified based on the RVESRI to RV systolic pressure relationship. During a mean follow-up of 3.9±2.4 years, the primary end point of death, transplant, or admission for heart failure was reached in 88 patients. RVESRI was incremental to risk prediction scores in pulmonary arterial hypertension, including the Registry to Evaluate Early and Long-Term PAH Disease Management score, the Pulmonary Hypertension Connection equation, and the Mayo Clinic model. Using multivariable analysis, New York Heart Association class III/IV, RVESRI, and log NT-proBNP (N-Terminal Pro-B-Type Natriuretic Peptide) were retained (χ 2 , 62.2; P <0.0001). Changes in RVESRI at 1 year (n=203) were predictive of outcome; patients initiated on prostanoid therapy showed the greatest improvement in RVESRI. Among right heart metrics, RVESRI demonstrated the best test-retest characteristics. RVESRI is a simple reproducible prognostic marker in patients with pulmonary arterial hypertension. © 2017 American Heart Association, Inc.
Effects of novel muscarinic M3 receptor ligand C1213 in pulmonary arterial hypertension models.
Ahmed, Mohamed; VanPatten, Sonya; Lakshminrusimha, Satyan; Patel, Hardik; Coleman, Thomas R; Al-Abed, Yousef
2016-12-01
Pulmonary hypertension (PH) is a complex disease comprising a pathologic remodeling and thickening of the pulmonary vessels causing an after load on the right heart ventricle that can result in ventricular failure. Triggered by oxidative stress, episodes of hypoxia, and other undetermined causes, PH is associated with poor outcomes and a high rate of morbidity. In the neonate, this disease has a similar etiology but is further complicated by the transition to breathing after birth, which requires a reduction in vascular resistance. Persistent pulmonary hypertension of the newborn (PPHN) is one form of PH that is frequently unresponsive to current therapies including inhaled nitric oxide (due to lack of proper absorption and diffusion), and other therapeutics targeting signaling mediators in vascular endothelium and smooth muscle. The need for novel agents, which target distinct pathways in pulmonary hypertension, remains. Herein, we investigated the therapeutic effects of novel muscarinic receptor ligand C1213 in models of PH We demonstrated that via M3 muscarinic receptors, C1213 induced activating- eNOS phosphorylation (serine-1177), which is known to lead to nitric oxide (NO) production in endothelial cells. Using signaling pathway inhibitors, we discovered that AKT and calcium signaling contributed to eNOS phosphorylation induced by C1213. As expected for an eNOS-stimulating agent, in ex vivo and in vivo models, C1213 triggered pulmonary vasodilation and induced both pulmonary artery and systemic blood pressure reductions demonstrating its potential value in PH and PPHN In brief, this proof-of-concept study provides evidence that an M3 muscarinic receptor functionally selective ligand stimulates downstream pathways leading to antihypertensive effects using in vitro, ex vivo, and in vivo models of PH. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.
Lung volumes during sustained microgravity on Spacelab SLS-1
NASA Technical Reports Server (NTRS)
Elliott, Ann R.; Prisk, Gordon Kim; Guy, Harold J. B.; West, John B.
1994-01-01
Gravity is known to influence the topographical gradients of pulmonary ventilation, perfusion, and pleural pressures. The effect of sustained microgravity on lung volumes has not previously been investigated. Pulmonary function tests were performed by four subjects before, during, and after 9 days of microgravity exposure. Ground measurements were made in standing and supine postures. Tests were performed using a bag-in-box and flowmeter system and a respiratory mass spectrometer. Measurements of tidal volume (V(sub T)), expiratory reserve volume (ERV), inspiratory and expiratory vital capacities (IVC, EVC), functional residual capacity (FRC), and residual volume (RV) were made. During microgravity, V(sub T) decreased by 15%. IVC and EVC were slightly reduced during the first 24 hrs of microgravity and returned to 1 g standing values within 72 hrs after the onset of microgravity. FRC was reduced by 15% and ERV decreased by 10-20%. RV was significantly reduced by 18%. The reductions in FRC, ERV, and V(sub T) during microgravity are probably due to the cranial shift of the diaphragm and an increase in intrathoracic blood volume.
Effects of ozone and nitrogen dioxide on pulmonary function in healthy and in asthmatic adolescents
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koenig, J.Q.; Covert, D.S.; Marshall, S.G.
The aim of this project was to investigate whether well-characterized asthmatic adolescent subjects were more sensitive to the inhaled effects of oxidant pollutants than were well-characterized healthy adolescent subjects. Ten healthy and 10 asthmatic subjects inhaled via a mouth-piece 0.12 or 0.18 ppm of ozone (O/sub 3/) or nitrogen dioxide (NO/sub 2/) or clean air for 30 min at rest followed by 10 min during moderate exercise (32.5 L/min) on a treadmill. The following pulmonary functional values were measured before and after exposure: peak flow, total respiratory resistance (RT), maximal flow at 50 and 75% of expired VC, and FEV1.more » After exercise exposure to 0.18 ppm O3, statistically significant increases were seen in RT in asthmatic and healthy adolescent subjects. No consistent changes were seen in either group after NO/sub 2/ exposure. Also, no significant differences in response to oxidant pollutants between the 2 groups could be demonstrated. It was concluded that neither group was consistently sensitive to these pollutants.« less
Role of pulmonary diseases and physical condition in the regulation of vasoactive hormones.
Hietanen, E; Marniemi, J; Liippo, K; Seppänen, A; Hartiala, J; Viinamäki, O
1988-12-01
Lungs have many non-respiratory metabolic functions, of which some take place in the capillary endothelium, while others are in parenchymal lung tissue. We have studied the role of the lungs in the metabolism of vasoactive and some other hormones by comparing patients who have undergone lung resection to those having various obstructive or fibrotic lung diseases. We have also compared these groups with persons in good physical health. The data suggested that lung resection patients had low angiotensin II levels in plasma but the response of angiotensin II to exercise was normal. Also adrenalin concentration was low in the lung resection group while dopamine did not show any significant difference between the groups. When hormone levels were correlated to the exercise data, renin levels were especially related to physical condition. Serum post-exercise renin values were inversely related to the uneven distribution of lung perfusion, possibly thus reflecting the diminished pulmonary vascularization. A negative association was found between angiotensin II and diffusion capacity. Thus, the angiotensin II levels may preferably be controlled by the non-circulatory functions of the lungs.
Mehani, Sherin Hassan Mohammed
2017-01-01
The aim of the present study was to compare threshold inspiratory muscle training (IMT) and expiratory muscle training (EMT) in elderly male patients with moderate degree of COPD. Forty male patients with moderate degree of COPD were recruited for this study. They were randomly divided into two groups: the IMT group who received inspiratory training with an intensity ranging from 15% to 60% of their maximal inspiratory pressure, and the EMT group who received expiratory training with an equal intensity which was adjusted according to the maximal expiratory pressure. Both groups received training three times per week for 2 months, in addition to their prescribed medications. Both IMT and EMT groups showed a significant improvement in forced vital capacity, forced expiratory volume in the first second, forced expiratory volume in the first second% from the predicted values, and forced vital capacity% from the predicted value, with no difference between the groups. Both types of training resulted in a significant improvement in blood gases (SaO 2 %, PaO 2 , PaCO 2 , and HCO 3 ), with the inspiratory muscle group showing the best results. Both groups showed a significant improvement in the 6-min walking distance: an increase of about 25% in the inspiratory muscle group and about 2.5% in the expiratory muscle group. Both IMT and EMT must be implemented in pulmonary rehabilitation programs in order to achieve improvements in pulmonary function test, respiratory muscle strength, blood oxygenation, and 6-min walking distance.
García-Montes, José Antonio; Zabal Cerdeira, Carlos; Calderón-Colmenero, Juan; Espínola, Nilda; Fernández de la Reguera, Guillermo; Buendía Hernández, Alfonso
2005-01-01
Surgical treatment of multiple muscular ventricular septal defects with associated lesions and severe pulmonary hypertension has a high morbility and mortality. Closure of these defects by the Amplatzer muscular VSD occluder is an alternative to surgery, avoiding the need of cardiopulmonary bypass. We present the case of a 38 year-old woman with signs of heart failure in NYHA functional class IV, with two muscular ventricular septal defects, patent ductus arteriosus and severe pulmonary hypertension, that were treated with three Amplatzer muscular VSD occluders, with significant reduction of pulmonary pressure and functional class improvement.
Recent lung imaging studies. [Effectiveness for diagnosis of chronic obstructive pulmonary disease
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taplin, G.V.; Chopra, S.K.
1976-01-01
Radionuclide lung imaging procedures have been available for 11 years but only the perfusion examination has been used extensively and mainly for the diagnosis of pulmonary embolism (P.E.). Its ability to reveal localized ischemia makes it a valuable test of regional lung function as well as a useful diagnostic aid in P.E. Although it had been recognized for several years that chronic obstructive pulmonary disease (COPD) can cause lung perfusion defects which may simulate pulmonary embolism, relatively little use has been made of either the radioxenon or the radioaerosol inhalation lung imaging procedures until the last few years as amore » means of distinguishing P.E. from COPD. In this review emphasis is placed on our recent experience with both of these inhalation procedures in comparison with pulmonary function tests and roentgenography for the early detection of COPD in population studies. Equal emphasis is given to simultaneous aerosol ventilation-perfusion (V/P) imaging for a functional diagnosis of P.E. Two new developments in regional lung diffusion imaging, performed after the inhalation of radioactive gases and/or rapidly absorbed radioaerosols are described. The experimental basis for their potential clinical application in pulmonary embolism detection is presented.« less
D'Armini, Andrea M; Ghofrani, Hossein-Ardeschir; Kim, Nick H; Mayer, Eckhard; Morsolini, Marco; Pulido-Zamudio, Tomás; Simonneau, Gerald; Wilkins, Martin R; Curram, John; Davie, Neil; Hoeper, Marius M
2015-03-01
In the Chronic Thromboembolic Pulmonary Hypertension Soluble Guanylate Cyclase - Stimulator Trial 1 (CHEST-1) study, riociguat improved 6-minute walking distance (6MWD) vs placebo in patients with inoperable chronic thromboembolic pulmonary hypertension or persistent/recurrent pulmonary hypertension after pulmonary endarterectomy. In this study, the proportion of patients who achieved responder thresholds that correlate with improved outcome in patients with pulmonary arterial hypertension was determined at baseline and at the end of CHEST-1. Patients received placebo or riociguat individually adjusted up to 2.5 mg 3 times a day for 16 weeks. Response criteria were defined as follows: 6MWD increase ≥40 m, 6MWD ≥380 m, cardiac index ≥2.5 liters/min/m(2), pulmonary vascular resistance <500 dyn∙sec∙cm(-5), mixed venous oxygen saturation ≥65%, World Health Organization functional class I/II, N-terminal pro-brain natriuretic peptide <1,800 pg/ml, and right atrial pressure <8 mm Hg. Riociguat increased the proportion of patients with 6MWD ≥380 m, World Health Organization functional class I/II, and pulmonary vascular resistance <500 dyn∙sec∙cm(-5) from 37%, 34%, and 25% at baseline to 58%, 57%, and 50% at Week 16, whereas there was little change in placebo-treated patients (6MWD ≥380 m, 43% vs 44%; World Health Organization functional class I/II, 29% vs 38%; pulmonary vascular resistance <500 dyn∙sec∙cm(-5), 27% vs 26%). Similar changes were observed for thresholds for cardiac index, mixed venous oxygen saturation, N-terminal pro-brain natriuretic peptide, and right atrial pressure. In this exploratory analysis, riociguat increased the proportion of patients with inoperable chronic thromboembolic pulmonary hypertension or persistent/recurrent pulmonary hypertension after pulmonary endarterectomy achieving criteria defining a positive response to therapy. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Clinical characteristics of obesity-hypoventilation syndrome in Japan: a multi-center study.
Akashiba, Tsuneto; Akahoshi, Toshiki; Kawahara, Seiji; Uematsu, Akihito; Katsura, Kazuhito; Sakurai, Shigeru; Murata, Akira; Sakakibara, Hiroki; Chin, Kazuo; Hida, Wataru; Nakamura, Hiroshi
2006-01-01
To clarify the prevalence and clinical characteristics of obesity-hypoventilation syndrome (OHS) in a large number of patients with moderate to severe obstructive sleep apnea syndrome (OSAS). Subjects comprised 611 patients with OSAS registered from 7 sleep centers and clinics and analyzed according to the definitions of the Respiratory Failure Research Group of the Japanese Ministry of Health and Welfare. Baseline characteristics, polysomnographic data during sleep, laboratory blood examinations, excessive daytime sleepiness, pulmonary functions, and arterial blood gases were compared between OHS and non-OHS patients. Determinants of daytime hypercapnia were also examined in OHS patients. OHS was identified in 55 of the 611 patients with OSAS (9%). OHS patients were younger, heavier, and more somnolent than non-OHS patients and displayed more severe OSAS, liver dysfunctions, higher total cholesterol, and impaired pulmonary function. However, these differences were resolved except for pulmonary function after correction for obesity. Daytime hypercapnia was associated with impaired pulmonary function. Percent vital capacity (%VC) was most closely correlated with PaCO2 in OHS. OHS patients display numerous abnormalities due to obesity compared with non-OHS patients. Impaired pulmonary function, particularly %VC, may play an important role in the development of daytime hypercapnia independent of obesity in OHS patients.
Pulmonary Screening in Subjects after the Fontan Procedure.
Liptzin, Deborah R; Di Maria, Michael V; Younoszai, Adel; Narkewicz, Michael R; Kelly, Sarah L; Wolfe, Kelly R; Veress, Livia A
2018-05-07
To review the pulmonary findings of the first 51 patients who presented to our interdisciplinary single-ventricle clinic after undergoing the Fontan procedure. We performed an Institutional Review Board-approved retrospective review of 51 patients evaluated following the Fontan procedure. Evaluation included history, physical examination, pulmonary function testing, and 6-minute walk. Descriptive statistics were used to describe the population and testing data. Sixty-one percent of the patients had a pulmonary concern raised during the visit. Three patients had plastic bronchitis. Abnormal lung function testing was present in 46% of patients. Two-thirds (66%) of the patients had significant desaturation during the 6-minute walk test. Patients who underwent a fenestrated Fontan procedure and those who underwent unfenestrated Fontan were compared in terms of saturation and 6-minute walk test results. Sleep concerns were present in 45% of the patients. Pulmonary morbidities are common in patients after Fontan surgery and include plastic bronchitis, abnormal lung function, desaturations with walking, and sleep concerns. Abnormal lung function and obstructive sleep apnea may stress the Fontan circuit and may have implications for cognitive and emotional functioning. A pulmonologist involved in the care of patients after Fontan surgery can assist in screening for comorbidities and recommend interventions. Copyright © 2018 Elsevier Inc. All rights reserved.
Infection, inflammation, and lung function decline in infants with cystic fibrosis.
Pillarisetti, Naveen; Williamson, Elizabeth; Linnane, Barry; Skoric, Billy; Robertson, Colin F; Robinson, Phil; Massie, John; Hall, Graham L; Sly, Peter; Stick, Stephen; Ranganathan, Sarath
2011-07-01
Better understanding of evolution of lung function in infants with cystic fibrosis (CF) and its association with pulmonary inflammation and infection is crucial in informing both early intervention studies aimed at limiting lung damage and the role of lung function as outcomes in such studies. To describe longitudinal change in lung function in infants with CF and its association with pulmonary infection and inflammation. Infants diagnosed after newborn screening or clinical presentation were recruited prospectively. FVC, forced expiratory volume in 0.5 seconds (FEV(0.5)), and forced expiratory flows at 75% of exhaled vital capacity (FEF(75)) were measured using the raised-volume technique, and z-scores were calculated from published reference equations. Pulmonary infection and inflammation were measured in bronchoalveolar lavage within 48 hours of lung function testing. Thirty-seven infants had at least two successful repeat lung function measurements. Mean (SD) z-scores for FVC were -0.8 (1.0), -0.9 (1.1), and -1.7 (1.2) when measured at the first visit, 1-year visit, or 2-year visit, respectively. Mean (SD) z-scores for FEV(0.5) were -1.4 (1.2), -2.4 (1.1), and -4.3 (1.6), respectively. In those infants in whom free neutrophil elastase was detected, FVC z-scores were 0.81 lower (P=0.003), and FEV(0.5) z-scores 0.96 lower (P=0.001), respectively. Significantly greater decline in FEV(0.5) z-scores occurred in those infected with Staphylococcus aureus (P=0.018) or Pseudomonas aeruginosa (P=0.021). In infants with CF, pulmonary inflammation is associated with lower lung function, whereas pulmonary infection is associated with a greater rate of decline in lung function. Strategies targeting pulmonary inflammation and infection are required to prevent early decline in lung function in infants with CF.
[Normal lung volumes in patients with idiopathic pulmonary fibrosis and emphysema].
Casas, Juan Pablo; Abbona, Horacio; Robles, Adriana; López, Ana María
2008-01-01
Pulmonary function tests in idiopathic pulmonary fibrosis characteristically show a restrictive pattern, resulting from reduction of pulmonary compliance due to diffuse fibrosis. Conversely, an obstructive pattern with hyperinflation results in emphysema by loss of elastic recoil, expiratory collapse of the peripheral airways and air trapping. Previous reports suggest that when both diseases coexist, pulmonary volumes are compensated and a smaller than expected reduction or even normal lung volumes can be found. We report 4 male patients of 64, 60, 73 and 70 years, all with heavy cigarette smoking history and progressive breathlessness. Three of them had severe limitation in their quality of life. All four showed advanced lung interstitial involvement, at high resolution CT scan, fibrotic changes predominantly in the subpleural areas of lower lung fields and concomitant emphysema in the upper lobes. Emphysema and pulmonary fibrosis was confirmed by open lung biopsy in one patient. The four patients showed normal spirometry and lung volumes with severe compromise of gas exchange and poor exercise tolerance evaluated by 6 minute walk test. Severe pulmonary arterial hypertension was also confirmed in three patients. Normal lung volumes does not exclude diagnosis of idiopathic pulmonary fibrosis in patients with concomitant emphysema. The relatively preserved lung volumes may underestimate the severity of idiopathic pulmonary fibrosis and attenuate its effects on lung function parameters.
Li, Ji-Feng; Zhai, Zhen-Guo; Kuang, Tu-Guang; Liu, Min; Ma, Zhan-Hong; Li, Yi-Dan; Yang, Yuan-Hua
2017-08-01
Pulmonary hypertension (PH) can be caused by a fistula between the systemic and pulmonary arteries. Here, we report a case of PH due to multiple fistulas between systemic arteries and the right pulmonary artery where the ventilation/perfusion scan showed no perfusion in the right lung. A 32-year-old male patient was hospitalised for community-acquired pneumonia. After treatment with antibiotics, the pneumonia was alleviated but dyspnoea persisted. Pulmonary hypertension was diagnosed using right heart catheterisation, which detected the mean pulmonary artery pressure as 37mmHg. The anomalies were confirmed by contrast-enhanced CT scan (CT pulmonary angiography), systemic arterial angiography and pulmonary angiography. Following embolisation of the largest fistula, the haemodynamics and oxygen dynamics did not improve, and even worsened to some extent. After supportive therapy including diuretics and oxygen, the patient's dyspnoea, WHO function class and right heart function by transthoracic echocardiography all improved during follow-up. Pulmonary hypertension can be present even when the right lung perfusion is lost. Closure of fistulas by embolisation, when those fistulas act as the proliferating vessels, may be harmful. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Lee, Sung-soon; Kim, Changhwan; Jin, Young-Soo; Oh, Yeon-Mok; Lee, Sang-Do; Yang, Yun Jun; Park, Yong Bum
2013-05-01
Despite documented efficacy and recommendations, pulmonary rehabilitation (PR) in chronic obstructive pulmonary disease (COPD) has been underutilized. Home-based PR was proposed as an alternative, but there were limited data. The adequate exercise intensity was also a crucial issue. The aim of this study was to investigate the effects of home-based PR with a metronome-guided walking pace on functional exercise capacity and health-related quality of life (HRQOL) in COPD. The subjects participated in a 12-week home-based PR program. Exercise intensity was initially determined by cardiopulmonary exercise test, and was readjusted (the interval of metronome beeps was reset) according to submaximal endurance test. Six-minute walk test, pulmonary function test, cardiopulmonary exercise test, and St. George's Respiratory Questionnaire (SGRQ) were done before and after the 12-week program, and at 6 months after completion of rehabilitation. Thirty-three patients participated in the program. Six-minute walking distance was significantly increased (48.8 m; P = 0.017) and the SGRQ score was also improved (-15; P < 0.001) over the six-month follow-up period after rehabilitation. There were no significant differences in pulmonary function and peak exercise parameters. We developed an effective home-based PR program with a metronome-guided walking pace for COPD patients. This rehabilitation program may improve functional exercise capacity and HRQOL.
Patel, Neil
2012-01-01
Pulmonary hypertension and secondary cardiac dysfunction are important contributors of morbidity and mortality in infants with congenital diaphragmatic hernia (CDH). Milrinone, a phosphodiesterase-3 inhibitor, may be useful in this setting for its combined actions as a pulmonary vasodilator and to improve systolic and diastolic function. This study aimed to assess the effects of milrinone on cardiac function and pulmonary artery pressure in infants with CDH. A retrospective review of echocardiograms performed on infants with CDH who received milrinone was performed. Tissue Doppler imaging velocities were used to assess systolic and diastolic function. Pulmonary artery pressure was assessed from the pattern and velocity of ductal shunting. Six infants with CDH and severe pulmonary hypertension were identified. Systolic and diastolic myocardial velocities were reduced in the right ventricle (RV) and interventricular septum (IVS) at baseline. In the 72 h after commencement of milrinone, there was a significant increase in early diastolic myocardial velocities in the RV, accompanied by increasing systolic velocities in the RV and IVS. Oxygenation index was significantly reduced, blood pressure unchanged, and ductal shunt velocity minimally altered over the same time period. Milrinone use was associated with an improvement in systolic and diastolic function in the RV, corresponding to an improvement in clinical status. Copyright © 2012 S. Karger AG, Basel.
Wink, Jeroen; de Wilde, Rob B P; Wouters, Patrick F; van Dorp, Eveline L A; Veering, Bernadette Th; Versteegh, Michel I M; Aarts, Leon P H J; Steendijk, Paul
2016-10-18
Blockade of cardiac sympathetic fibers by thoracic epidural anesthesia may affect right ventricular function and interfere with the coupling between right ventricular function and right ventricular afterload. Our main objectives were to study the effects of thoracic epidural anesthesia on right ventricular function and ventricular-pulmonary coupling. In 10 patients scheduled for lung resection, right ventricular function and its response to increased afterload, induced by temporary, unilateral clamping of the pulmonary artery, was tested before and after induction of thoracic epidural anesthesia using combined pressure-conductance catheters. Thoracic epidural anesthesia resulted in a significant decrease in right ventricular contractility (ΔESV 25 : +25.5 mL, P=0.0003; ΔEes: -0.025 mm Hg/mL, P=0.04). Stroke work, dP/dt MAX , and ejection fraction showed a similar decrease in systolic function (all P<0.05). A concomitant decrease in effective arterial elastance (ΔEa: -0.094 mm Hg/mL, P=0.004) yielded unchanged ventricular-pulmonary coupling. Cardiac output, systemic vascular resistance, and mean arterial blood pressure were unchanged. Clamping of the pulmonary artery significantly increased afterload (ΔEa: +0.226 mm Hg/mL, P<0.001). In response, right ventricular contractility increased (ΔESV 25 : -26.6 mL, P=0.0002; ΔEes: +0.034 mm Hg/mL, P=0.008), but ventricular-pulmonary coupling decreased (Δ(Ees/Ea) = -0.153, P<0.0001). None of the measured indices showed significant interactive effects, indicating that the effects of increased afterload were the same before and after thoracic epidural anesthesia. Thoracic epidural anesthesia impairs right ventricular contractility but does not inhibit the native positive inotropic response of the right ventricle to increased afterload. Right ventricular-pulmonary arterial coupling was decreased with increased afterload but not affected by the induction of thoracic epidural anesthesia. URL: http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=2844. Unique identifier: NTR2844. © 2016 American Heart Association, Inc.
Pulmonary physiology during pulmonary embolism.
Elliott, C G
1992-04-01
Acute pulmonary thromboembolism produces a number of pathophysiologic derangements of pulmonary function. Foremost among these alterations is increased pulmonary vascular resistance. For patients without preexistent cardiopulmonary disease, increased pulmonary vascular resistance is directly related to the degree of vascular obstruction demonstrated on the pulmonary arteriogram. Vasoconstriction, either reflexly or biochemically mediated, may contribute to increased pulmonary vascular resistance. Acute pulmonary thromboembolism also disturbs matching of ventilation and blood flow. Consequently, some lung units are overventilated relative to perfusion (increased dead space), while other lung units are underventilated relative to perfusion (venous admixture). True right-to-left shunting of mixed venous blood can occur through the lungs (intrapulmonary shunt) or across the atrial septum (intracardiac shunt). In addition, abnormalities of pulmonary gas exchange (carbon monoxide transfer), pulmonary compliance and airway resistance, and ventilatory control may accompany pulmonary embolism. Thrombolytic therapy can reverse the hemodynamic derangements of acute pulmonary thromboembolism more rapidly than anticoagulant therapy. Limited data suggest a sustained benefit of thrombolytic treatment on the pathophysiologic alterations of pulmonary vascular resistance and pulmonary gas exchange produced by acute pulmonary emboli.
Diagnostic values of NT-proBNP in acute dyspnea among elderly patients
Su, Qin; Liu, Hongsheng; Zhang, Xian; Dang, Wei; Liu, Runmei; Zhao, Xiaodong; Yuan, Xiaoling; Qin, Yuhong; Zhang, Jianbo; Chen, Chunming; Xia, Yunfeng
2015-01-01
The study aims to evaluate a rapid testing of NT-proBNP in differential diagnosis of cardiac and pulmonary dyspnea among elderly emergency patients. Two hundred sixty-eight dyspnea patients with ages of ≥60 years old participated in the study. Based on their clinical diagnosis, the patients were divided into three groups: group A diagnosed with pulmonary dyspnea (PD), group B diagnosed with congestive heart failure (CHF), and group C diagnosed with combined dyspnea (CHF+PD). NT-proBNP levels among the three groups were compared. NT-proBNP levels in group A were significantly lower than those in groups B and C. No significant difference was observed between groups B and C in terms of NT-proBNP levels (P>0.05). Our data showed that NT-proBNP levels in patients with cardiac dyspnea were significantly higher than those in patients with pulmonary dyspnea. Person linear association analysis revealed that NT-proBNP levels were reversely associated with LVEF (r=-0.675, P<0.01), indicating that higher NT-proBNP levels result in lower LVEF and poorer heart functions. NT-proBNP is a valuable biomarker in differential diagnosis of pulmonary and cardiac dyspnea among elderly patients due to the high sensitivity of the testing method and the strong association with the severity of heart failure. PMID:26722559
A computer system for processing data from routine pulmonary function tests.
Pack, A I; McCusker, R; Moran, F
1977-01-01
In larger pulmonary function laboratories there is a need for computerised techniques of data processing. A flexible computer system, which is used routinely, is described. The system processes data from a relatively large range of tests. Two types of output are produced--one for laboratory purposes, and one for return to the referring physician. The system adds an automatic interpretative report for each set of results. In developing the interpretative system it has been necessary to utilise a number of arbitrary definitions. The present terminology for reporting pulmonary function tests has limitations. The computer interpretation system affords the opportunity to take account of known interaction between measurements of function and different pathological states. Images PMID:329462
Kirkhus, Niels E; Skare, Øivind; Ulvestad, Bente; Aaløkken, Trond Mogens; Günther, Anne; Olsen, Raymond; Thomassen, Yngvar; Lund, May Brit; Ellingsen, Dag G
2018-04-01
The aim of this study was to assess short-term changes in pulmonary function in drill floor workers currently exposed to airborne contaminants generated as a result of drilling offshore. We also aimed to study the prevalence of pulmonary fibrosis using high-resolution computed tomography (HRCT) scans of another group of previously exposed drill floor workers. Pulmonary function was measured before and after a 14-day work period in a follow-up study of 65 drill floor workers and 65 referents. Additionally, 57 other drill floor workers exposed to drilling fluids during the 1980s were examined with HRCT of the lungs in a cross-sectional study. The drill floor workers had a statistically significant decline in forced expiratory volume in 1 s (FEV 1 ) across the 14-day work period after adjustment for diurnal variations in pulmonary function (mean 90 mL, range 30-140 mL), while the small decline among the referents (mean 20 mL, range - 30 to 70 mL) was not of statistical significance. Larger declines in FEV 1 among drill workers were associated with the fewer number of days of active drilling. There were no signs of pulmonary fibrosis related to oil mist exposure among the other previously exposed drill floor workers. After 14 days offshore, a statistically significant decline in FEV 1 was observed in the drill floor workers, which may not be related to oil mist exposure. No pulmonary fibrosis related to oil mist exposure was observed.
Jacob, Joseph; Bartholmai, Brian J; Rajagopalan, Srinivasan; Kokosi, Maria; Nair, Arjun; Karwoski, Ronald; Raghunath, Sushravya M; Walsh, Simon L F; Wells, Athol U; Hansell, David M
2016-09-01
The aim of the study was to determine whether a novel computed tomography (CT) postprocessing software technique (CALIPER) is superior to visual CT scoring as judged by functional correlations in idiopathic pulmonary fibrosis (IPF). A total of 283 consecutive patients with IPF had CT parenchymal patterns evaluated quantitatively with CALIPER and by visual scoring. These 2 techniques were evaluated against: forced expiratory volume in 1 second (FEV1), forced vital capacity (FVC), diffusing capacity for carbon monoxide (DLco), carbon monoxide transfer coefficient (Kco), and a composite physiological index (CPI), with regard to extent of interstitial lung disease (ILD), extent of emphysema, and pulmonary vascular abnormalities. CALIPER-derived estimates of ILD extent demonstrated stronger univariate correlations than visual scores for most pulmonary function tests (PFTs): (FEV1: CALIPER R=0.29, visual R=0.18; FVC: CALIPER R=0.41, visual R=0.27; DLco: CALIPER R=0.31, visual R=0.35; CPI: CALIPER R=0.48, visual R=0.44). Correlations between CT measures of emphysema extent and PFTs were weak and did not differ significantly between CALIPER and visual scoring. Intriguingly, the pulmonary vessel volume provided similar correlations to total ILD extent scored by CALIPER for FVC, DLco, and CPI (FVC: R=0.45; DLco: R=0.34; CPI: R=0.53). CALIPER was superior to visual scoring as validated by functional correlations with PFTs. The pulmonary vessel volume, a novel CALIPER CT parameter with no visual scoring equivalent, has the potential to be a CT feature in the assessment of patients with IPF and requires further exploration.
Oki, Hiroshi; Yazawa, Takuya; Baba, Yasuko; Kanegae, Yumi; Sato, Hanako; Sakamoto, Seiko; Goto, Takahisa; Saito, Izumu; Kurahashi, Kiyoyasu
2017-07-01
Pulmonary emphysema impairs quality of life and increases mortality. It has previously been shown that administration of adenovirus vector expressing murine keratinocyte growth factor (KGF) before elastase instillation prevents pulmonary emphysema in mice. We therefore hypothesized that therapeutic administration of KGF would restore damage to lungs caused by elastase instillation and thus improve pulmonary function in an animal model. KGF expressing adenovirus vector, which prevented bleomycin-induced pulmonary fibrosis in a previous study, was constructed. Adenovirus vector (1.0 × 10 9 plaque-forming units) was administered intratracheally one week after administration of elastase into mouse lungs. One week after administration of KGF-vector, exercise tolerance testing and blood gas analysis were performed, after which the lungs were removed under deep anesthesia. KGF-positive pneumocytes were more numerous, surfactant protein secretion in the airspace greater and mean linear intercept of lungs shorter in animals that had received KGF than in control animals. Unexpectedly, however, arterial blood oxygenation was worse in the KGF group and maximum running speed, an indicator of exercise capacity, had not improved after KGF in mice with elastase-induced emphysema, indicating that KGF-expressing adenovirus vector impaired pulmonary function in these mice. Notably, vector lacking KGF-expression unit did not induce such impairment, implying that the KGF expression unit itself may cause the damage to alveolar cells. Possible involvement of the CAG promoter used for KGF expression in impairing pulmonary function is discussed. © 2017 The Societies and John Wiley & Sons Australia, Ltd.
Pulmonary Outcomes in Survivors of Childhood Cancer
Hudson, Melissa M.; Stokes, Dennis C.; Krasin, Matthew J.; Spunt, Sheri L.; Ness, Kirsten K.
2011-01-01
Background: The purpose of this article is to summarize the literature that documents the long-term impact of cancer treatment modalities on pulmonary function among survivors of cancer and to identify potential areas for further research. Methods: Systematic reviews of clinical trials, observational studies, case series, and review articles were conducted. Articles were limited to the studies that discussed pulmonary toxicity or late effects among pediatric cancer survivors and to follow-up investigations that were conducted a minimum of 2 years after completion of cancer-related treatment or 1 year after hematopoietic stem cell transplant. Results: Sixty publications (51 clinical studies/reports and nine reviews) published from January 1970 to June 2010 in PubMed met the inclusion criteria. Data showed an association between radiotherapy, alkylating agents, bleomycin, hematopoietic stem cell transplant, and thoracic surgery and pulmonary toxicity, as well as possible interactions among these modalities. Conclusions: Pulmonary toxicity is a common long-term complication of exposure to certain anticancer therapies in childhood and can vary from subclinical to life threatening. Pulmonary function and associated loss of optimal exercise capacity may have adverse effects on long-term quality of life in survivors. Lung function diminishes as a function of normal aging, and the effects of early lung injury from cancer therapy may compound these changes. The information presented in this review is designed to provide a stimulus to promote both observational and interventional research that expands our knowledge and aids in the design of interventions to prevent or ameliorate pulmonary late effects among survivors of childhood cancer. PMID:21415131
McKenna, Stephen P; Ratcliffe, Julie; Meads, David M; Brazier, John E
2008-08-21
Pulmonary Hypertension is a severe and incurable disease with poor prognosis. A suite of new disease-specific measures--the Cambridge Pulmonary Hypertension Outcome Review (CAMPHOR) - was recently developed for use in this condition. The purpose of this study was to develop and validate a preference based measure from the CAMPHOR that could be used in cost-utility analyses. Items were selected that covered major issues covered by the CAMPHOR QoL scale (activities, travelling, dependence and communication). These were used to create 36 health states that were valued by 249 people representative of the UK adult population, using the time trade-off (TTO) technique. Data from the TTO interviews were analysed using both aggregate and individual level modelling. Finally, the original CAMPHOR validation data were used to validate the new preference based model. The predicted health state values ranged from 0.962 to 0.136. The mean level model selected for analyzing the data had good explanatory power (0.936), did not systematically over- or underestimate the observed mean health state values and showed no evidence of auto correlation in the prediction errors. The value of less than 1 reflects a background level of ill health in state 1111, as judged by the respondents. Scores derived from the new measure had excellent test-retest reliability (0.85) and construct validity. The CAMPHOR utility score appears better able to distinguish between WHO functional classes (II and III) than the EQ-5D and SF-6D. The tariff derived in this study can be used to classify an individual into a health state based on their responses to the CAMPHOR. The results of this study widen the evidence base for conducting economic evaluations of interventions designed to improve QoL for patients with PH.
Using Operational Analysis to Improve Access to Pulmonary Function Testing.
Ip, Ada; Asamoah-Barnieh, Raymond; Bischak, Diane P; Davidson, Warren J; Flemons, W Ward; Pendharkar, Sachin R
2016-01-01
Background. Timely pulmonary function testing is crucial to improving diagnosis and treatment of pulmonary diseases. Perceptions of poor access at an academic pulmonary function laboratory prompted analysis of system demand and capacity to identify factors contributing to poor access. Methods. Surveys and interviews identified stakeholder perspectives on operational processes and access challenges. Retrospective data on testing demand and resource capacity was analyzed to understand utilization of testing resources. Results. Qualitative analysis demonstrated that stakeholder groups had discrepant views on access and capacity in the laboratory. Mean daily resource utilization was 0.64 (SD 0.15), with monthly average utilization consistently less than 0.75. Reserved testing slots for subspecialty clinics were poorly utilized, leaving many testing slots unfilled. When subspecialty demand exceeded number of reserved slots, there was sufficient capacity in the pulmonary function schedule to accommodate added demand. Findings were shared with stakeholders and influenced scheduling process improvements. Conclusion. This study highlights the importance of operational data to identify causes of poor access, guide system decision-making, and determine effects of improvement initiatives in a variety of healthcare settings. Importantly, simple operational analysis can help to improve efficiency of health systems with little or no added financial investment.
Demirci, Hakan; Eniste, Koncuy; Basaran, Ebru Onuker; Ocakoglu, Gokhan; Yilmaz, Zeynep; Tuna, Sumeyye
2017-11-01
Spirometry is known to be a gold standard for the diagnosis of chronic obstructive pulmonary disease (COPD). COPD Assessment Test (CAT) is an eight-item questionnaire currently in use to evaluate patients with COPD. In the present study, we aimed to evaluate if CAT is an adequate tool for screening COPD. In total, 600 persons aging ⩾40 years old were randomly selected from three different family practice units located in the city center. CAT was asked to the participants and a spirometry was used to assess pulmonary obstruction. Pulmonary obstruction was defined as forced expiratory volume in first second/forced vital capacity (FEV1/FVC)<70% and then COPD diagnosis was confirmed with the reversibility test. The relationship between CAT results and pulmonary function test values was evaluated. In this sampling, the prevalence of COPD was 4.2%. Reliability of the CAT in the study group was acceptable (Cronbach's α: 0.84). The CAT scores was significantly higher in patients with COPD (P<0.001). There was a significant negative correlation between CAT score and FEV1, FVC and FEV1/FVC ratio (r=-0.31, P<0.001; r=-0.26, P<0.001; r=0.18, P=0.001). Among smokers, phlegm was the predominating symptom (P=0.01). Sensitivity of CAT was 66.67% and its specificity was 75.15% to determine COPD. CAT is a reliable questionnaire and there is an apparent relationship between the total CAT scores and COPD. However, CAT's ability to screen COPD is limited since it may miss the symptom-free cases.
Lung imaging in pulmonary disease
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taplin, G.V.; Chopra, S.K.
1976-01-01
Although it has been recognized for several years that chronic obstructive pulmonary disease (COPD) can cause lung perfusion defects which may simulate pulmonary embolism, relatively little use has been made of either the radioxenon or the radioaerosol inhalation lung imaging procedures until the last few years as a means of distinguishing pulmonary embolism (P.E.) from COPD is reported. Recent experience is reported with the use of both of these procedures in comparison with pulmonary function tests for the early detection of COPD in population studies and also in P.E. suspects. Equal emphasis is given to simultaneous aerosol ventilation-perfusion (V/P) imagingmore » in the differential diagnosis of P.E. Finally, this paper is concerned with new developments in regional lung diffusion imaging following the inhalation of radioactive gases and rapidly absorbed radioaerosols. Their experimental basis is presented and their potential clinical applications in pulmonary embolism are discussed. As a result of these investigations, a functional (V/P) diagnosis of pulmonary embolism in patients may be possible in the near future with a sequential radioaerosol inhalation procedure alone.« less
Kim, Nick H S; Fesler, Pierre; Channick, Richard N; Knowlton, Kirk U; Ben-Yehuda, Ori; Lee, Stephen H; Naeije, Robert; Rubin, Lewis J
2004-01-06
Pulmonary thromboendarterectomy (PTE) is the preferred treatment for chronic thromboembolic pulmonary hypertension (CTEPH), but persistent pulmonary hypertension after PTE, as a result of either inaccessible distal thrombotic material or coexistent intrinsic small-vessel disease, remains a major determinant of poor outcome. Conventional preoperative evaluation is unreliable in identifying patients at risk for persistent pulmonary hypertension or predicting postoperative hemodynamic outcome. We postulated that pulmonary arterial occlusion pressure waveform analysis, a technique that has been used for partitioning pulmonary vascular resistance, might identify CTEPH patients with significant distal, small-vessel disease. Twenty-six patients underwent preoperative right heart catheterization before PTE. Pulmonary artery occlusion waveform recordings were performed in triplicate. Postoperative hemodynamics after PTE were compared with preoperative partitioning of pulmonary vascular resistance derived from the occlusion data. Preoperative assessment of upstream resistance (Rup) correlated with both postoperative total pulmonary resistance index (R2=0.79, P<0.001) and postoperative mean pulmonary artery pressure (R2=0.75, P<0.001). All 4 postoperative deaths occurred in patients with a preoperative Rup <60%. Pulmonary arterial occlusion pressure waveform analysis may identify CTEPH patients at risk for persistent pulmonary hypertension and poor outcome after PTE. Patients with CTEPH and Rup value <60% appear to be at highest risk.
Association between pulmonary function and renal function: findings from China and Australia.
Yu, Dahai; Chen, Tao; Cai, Yamei; Zhao, Zhanzheng; Simmons, David
2017-05-01
The relationship between obstructive lung function and impaired renal function is unclear. This study investigated the dose-response relationship between obstructive lung function and impaired renal function. Two independent cross-sectional studies with representative sampling were applied. 1454 adults from rural Victoria, Australia (1298 with normal renal function, 156 with impaired renal function) and 5824 adults from Nanjing, China (4313 with normal renal function, 1511 with impaired renal function). Pulmonary function measurements included forced expiratory volume in one second (FEV1) and forced vital capacity (FVC). Estimated glomerular filtration rate (eGFR), and impaired renal function marked by eGFR <60 mL/min/1.73m 2 were used as outcome. eGFR increased linearly with FEV1 in Chinese participants and with FVC in Australians. A non-linear relationship with peaked eGFR was found for FEV1 at 2.65 L among Australians and for FVC at 2.78 L among Chinese participants, respectively. A non-linear relationship with peaked eGFR was found for the predicted percentage value of forced expiratory volume in 1 s (PFEV1) at 81-82% and for the predicted percentage value of forced vital capacity (PFVC) at 83-84% among both Chinese and Australian participants, respectively. The non-linear dose-response relationships between lung capacity measurements (both for FEV1 and FVC) and risk of impaired renal function were consistently identified in both Chinese and Australian participants. An increased risk of impaired renal function was found below 3.05 L both for FEV1 and FVC, respectively. The non-linear relationship between PFEV and PVC and the risk of impaired renal function were consistently identified in both Chinese and Australian participants. An increased risk of impaired renal function was found below 76-77% for PFEV1 and 79-80% for PFVC, respectively. In both Australian and Chinese populations, the risk of impaired renal function increased both with FEV1 and FVC below 3.05 L, with PFEV1 below 76-77% or with PFVC below 79-80%, respectively. Obstructive lung function was associated with increased risk of reduced renal function. The screen for impaired renal function in patients with obstructive lung disease might be useful to ensure there was no impaired renal function before the commencement of potentially nephrotoxic medication where indicated (eg diuretics).
Joyce, Emer; Kamperidis, Vasileios; Ninaber, Maarten K; Katsanos, Spyridon; Debonnaire, Philippe; Schalij, Martin J; Taube, Christian; Bax, Jeroen J; Delgado, Victoria; Ajmone Marsan, Nina
2016-09-01
Right ventricular (RV) function has not been systematically assessed in sarcoidosis. The aim of this study was to assess the prevalence and associates of RV dysfunction in sarcoidosis using global longitudinal peak systolic strain (GLS). Furthermore, whether RV dysfunction was associated with clinical outcomes was investigated. A total of 88 patients with sarcoidosis (mean age, 54 ± 13 years; 51% men) without known sarcoid-related or other structural heart disease or alternative etiologies of pulmonary hypertension were retrospectively included. RV GLS was measured using two-dimensional speckle-tracking echocardiography, and patients were stratified (using a previously defined cutoff value) as having preserved (RV GLS < -19%) or impaired (RV GLS ≥ -19%) RV function. An age- and gender-matched control group (n = 50) was included. The main outcome was all-cause mortality or clinical heart failure (hospitalization or New York Heart Association functional class ≥ III and/or deterioration by one or more classes). RV GLS was significantly reduced (-20.1 ± 4.6 vs -24.6 ± 1.8%, P = .001) in patients compared with control subjects. Patients with impaired RV function (n = 41) were older and had worse pulmonary function, worse left ventricular diastolic function, and lower tricuspid annular plane systolic excursion compared with patients with preserved RV function (n = 47). Lower tricuspid annular plane systolic excursion and diabetes were independent correlates of RV GLS. Over a median follow-up period of 37 months, 19 clinical end points occurred. Patients with impaired RV function were more likely to experience the clinical end point (log-rank P = .003). RV contractile dysfunction, identified using RV GLS, is common in patients with sarcoidosis without manifest cardiac involvement or pulmonary hypertension and is associated with adverse outcome. RV GLS may therefore be useful to detect sarcoidosis-related RV dysfunction at an earlier and potentially modifiable stage. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Ji, Lei; Lou, Yong-Liang; Wu, Zhong-Xiu; Jiang, Jin-Qin; Fan, Xing-Li; Wang, Li-Fang; Liu, Xiao-Xiang; Du, Peng; Yan, Jie; Sun, Ai-Hua
2017-09-01
Quick diagnosis of smear-negative pulmonary tuberculosis (TB) and extra-pulmonary TB are urgently needed in clinical diagnosis. Our research aims to investigate the usefulness of the interferon-γ release assay (IGRA) for the diagnosis of smear-negative pulmonary and extra-pulmonary TB. We performed TB antibody and TB-IGRA tests on 389 pulmonary TB patients (including 120 smear-positive pulmonary TB patients and 269 smear-negative pulmonary TB patients), 113 extra-pulmonary TB patients, 81 patients with other pulmonary diseases and 100 healthy controls. Blood samples for the TB-Ab test and the TB-IGRA were collected, processed, and interpreted according to the manufacturer's protocol. The detection ratio of smear-positive pulmonary TB patients and smear-negative pulmonary TB patients were 90.8% (109 of 120) and 89.6% (241 of 269), respectively. There was no statistically significant difference of its performance between these two sample sets (P > 0.05). The detection ratio of positive TB patients and extra-pulmonary TB patients were 90.0% (350 of 389) and 87.6% (99 of 113), respectively, which was not significantly different (P > 0.05). In this work, the total detection ratio using TB-IGRA was 89.4%, therefore TB-IGRA has diagnostic values in smear-negative pulmonary TB and extra-pulmonary TB diagnosis.
Borges, Daniel L; Silva, Mayara Gabrielle; Silva, Luan Nascimento; Fortes, João Vyctor; Costa, Erika Thalita; Assunção, Rebeca Pessoa; Lima, Carlos Magno; da Silva Nina, Vinícius José; Bernardo-Filho, Mário; Caputo, Danúbia Sá
2016-09-01
Physical activity is beneficial in several clinical situations and recommended for patients with ischemic heart disease, as well as for those undergoing cardiac surgery. In a randomized controlled trial, 34 patients underwent coronary artery bypass grafting. A randomized control group (n = 15) submitted to conventional physiotherapy. The intervention group (n = 19) received the same protocol plus additional aerobic exercise with cycle ergometer. Pulmonary function by spirometry, respiratory muscle strength by manovacuometry, and functional capacity through 6-minute walking test was assessed before surgery and at hospital discharge. There was significant reduction in pulmonary function in both groups. In both groups, inspiratory muscle strength was maintained while expiratory muscle strength significantly decreased. Functional capacity was maintained in the intervention group (364.5 [324.5 to 428] vs. 348 [300.7 to 413.7] meters, P = .06), but it decreased significantly in control group patients (320 [288.5 to 393.0] vs. 292 [237.0 to 336.0] meters, P = .01). A significant difference in functional capacity was also found in intergroup analyses at hospital discharge (P = .03). Aerobic exercise applied early on coronary artery bypass grafting patients may promote maintenance of functional capacity, with no impact on pulmonary function and respiratory muscle strength when compared with conventional physiotherapy.
Detection of lipoarabinomannan as a diagnostic test for tuberculosis.
Sada, E; Aguilar, D; Torres, M; Herrera, T
1992-01-01
A coagglutination technique was established for the detection of lipoarabinomannan of Mycobacterium tuberculosis in human serum samples and evaluated for its utility in the diagnosis of tuberculosis at the Instituto Nacional de Enfermedades Respiratorias in Mexico City. The test had a sensitivity of 88% in patients with sputum-smear-positive active pulmonary tuberculosis. The sensitivity in patients with active pulmonary tuberculosis negative for acid-fast bacilli in sputum was 67%. Less favorable results were obtained for patients with AIDS and tuberculosis, with a sensitivity of 57%. The specificity in control patients with lung diseases different from tuberculosis and in healthy subjects was 100%. The positive predictive value was 100%, and the negative predictive value for patients with sputum-positive active pulmonary tuberculosis was 97%. The results of this study suggest that the detection of lipoarabinomannan is an accurate test for the diagnosis of pulmonary tuberculosis. PMID:1401008
Dubois, Luc; Malthaner, Richard A
2010-12-01
We measured lung function before and after video-assisted thoracoscopic apical bullectomy and talc poudrage in patients with spontaneous pneumothoraces. Seventy-two patients were prospectively followed up for 12 months. The indications for surgery were recurrent pneumothoraces (n = 58), bilateral pneumothoraces (n = 8), and persistent air leak (n = 6). There were 46 males and 26 females with mean age of 29 years (range 15-61 years). The results were analyzed using paired t tests. There were no recurrences. There were 4 complications (5.6%): 1 wound infection, 1 case of pneumonia, and 2 persistent air leaks each lasting 1 week. There were no conversions to open surgery. Preoperative and 6-month pulmonary function test results were available on 41 patients, and 35 patients completed 12-month pulmonary function tests. Twelve-month values (mean percent ± SD) were as follows: Forced expiratory volume in 1 second fell from 95 ± 19 to 89 ± 16 (P = .02); forced expiratory volume in 1 second/forced vital capacity ratio was unchanged, 95 ± 12 versus 94 ± 13 (P = .9); total lung capacity fell from 106 ± 19 to 98 ± 12 (P = 0.002); vital capacity fell from 100 ± 22 to 96 ± 16 (P = .05); residual volume fell from 126 ± 32 to 107 ± 29 (P = .002); and diffusion capacity for carbon monoxide corrected for alveolar volume was unchanged, 88 ± 15 versus 91 ± 17 (P = .07). Flow rates and diffusion capacities were preserved, but lung volumes were slightly reduced at 1 year. Video-assisted thoracoscopic apical bullectomy and talc poudrage is an effective treatment for spontaneous pneumothoraces with a low complication rate and recurrence rate and only minor changes in pulmonary function at 1 year. Copyright © 2010 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Huang, Long Shuang; Mathew, Biji; Zhao, Yutong; Noth, Imre; Reddy, Sekhar P.; Harijith, Anantha; Usatyuk, Peter V.; Berdyshev, Evgeny V.; Kaminski, Naftali; Zhou, Tong; Zhang, Wei; Zhang, Yanmin; Rehman, Jalees; Kotha, Sainath R.; Gurney, Travis O.; Parinandi, Narasimham L.; Lussier, Yves A.; Garcia, Joe G. N.
2014-01-01
Rationale: Lysocardiolipin acyltransferase (LYCAT), a cardiolipin-remodeling enzyme regulating the 18:2 linoleic acid pattern of mammalian mitochondrial cardiolipin, is necessary for maintaining normal mitochondrial function and vascular development. We hypothesized that modulation of LYCAT expression in lung epithelium regulates development of pulmonary fibrosis. Objectives: To define a role for LYCAT in human and murine models of pulmonary fibrosis. Methods: We analyzed the correlation of LYCAT expression in peripheral blood mononuclear cells (PBMCs) with the outcomes of pulmonary functions and overall survival, and used the murine models to establish the role of LYCAT in fibrogenesis. We studied the LYCAT action on cardiolipin remodeling, mitochondrial reactive oxygen species generation, and apoptosis of alveolar epithelial cells under bleomycin challenge. Measurements and Main Results: LYCAT expression was significantly altered in PBMCs and lung tissues from patients with idiopathic pulmonary fibrosis (IPF), which was confirmed in two preclinical murine models of IPF, bleomycin- and radiation-induced pulmonary fibrosis. LYCAT mRNA expression in PBMCs directly and significantly correlated with carbon monoxide diffusion capacity, pulmonary function outcomes, and overall survival. In both bleomycin- and radiation-induced pulmonary fibrosis murine models, hLYCAT overexpression reduced several indices of lung fibrosis, whereas down-regulation of native LYCAT expression by siRNA accentuated fibrogenesis. In vitro studies demonstrated that LYCAT modulated bleomycin-induced cardiolipin remodeling, mitochondrial membrane potential, reactive oxygen species generation, and apoptosis of alveolar epithelial cells, potential mechanisms of LYCAT-mediated lung protection. Conclusions: This study is the first to identify modulation of LYCAT expression in fibrotic lungs and offers a novel therapeutic approach for ameliorating lung inflammation and pulmonary fibrosis. PMID:24779708
Pulmonary vascular function and exercise capacity in black sub-Saharan Africans.
Simaga, Bamodi; Vicenzi, Marco; Faoro, Vitalie; Caravita, Sergio; Di Marco, Giovanni; Forton, Kevin; Deboeck, Gael; Lalande, Sophie; Naeije, Robert
2015-09-01
Sex and age affect the pulmonary circulation. Whether there may be racial differences in pulmonary vascular function is unknown. Thirty white European Caucasian subjects (15 women) and age and body-size matched 30 black sub-Saharan African subjects (15 women) underwent a cardiopulmonary exercise test and exercise stress echocardiography with measurements of pulmonary artery pressure (PAP) and cardiac output (CO). A pulmonary vascular distensibility coefficient α was mathematically determined from the natural curvilinearity of multipoint mean PAP (mPAP)-CO plots. Maximum oxygen uptake (V̇o2max) and workload were higher in the whites, while maximum respiratory exchange ratio and ventilatory equivalents for CO2 were the same. Pulmonary hemodynamics were not different at rest. Exercise was associated with a higher maximum total pulmonary vascular resistance, steeper mPAP-CO relationships, and lower α-coefficients in the blacks. These differences were entirely driven by higher slopes of mPAP-CO relationships (2.5 ± 0.7 vs. 1.4 ± 0.7 mmHg·l(-1)·min; P < 0.001) and lower α-coefficients (0.85 ± 0.33 vs. 1.35 ± 0.51%/mmHg; P < 0.01) in black men compared with white men. There were no differences in any of the hemodynamic variables between black and white women. In men only, the slopes of mPAP-CO relationships were inversely correlated to V̇o2max (P < 0.01). Thus the pulmonary circulation is intrinsically less distensible in black sub-Saharan African men compared with white Caucasian Europeans men, and this is associated with a lower exercise capacity. This study did not identify racial differences in pulmonary vascular function in women. Copyright © 2015 the American Physiological Society.
Deficiency of Akt1, but not Akt2, attenuates the development of pulmonary hypertension
Tang, Haiyang; Chen, Jiwang; Fraidenburg, Dustin R.; Song, Shanshan; Sysol, Justin R.; Drennan, Abigail R.; Offermanns, Stefan; Ye, Richard D.; Bonini, Marcelo G.; Minshall, Richard D.; Garcia, Joe G. N.; Machado, Roberto F.; Makino, Ayako
2014-01-01
Pulmonary vascular remodeling, mainly attributable to enhanced pulmonary arterial smooth muscle cell proliferation and migration, is a major cause for elevated pulmonary vascular resistance and pulmonary arterial pressure in patients with pulmonary hypertension. The signaling cascade through Akt, comprised of three isoforms (Akt1–3) with distinct but overlapping functions, is involved in regulating cell proliferation and migration. This study aims to investigate whether the Akt/mammalian target of rapamycin (mTOR) pathway, and particularly which Akt isoform, contributes to the development and progression of pulmonary vascular remodeling in hypoxia-induced pulmonary hypertension (HPH). Compared with the wild-type littermates, Akt1−/− mice were protected against the development and progression of chronic HPH, whereas Akt2−/− mice did not demonstrate any significant protection against the development of HPH. Furthermore, pulmonary vascular remodeling was significantly attenuated in the Akt1−/− mice, with no significant effect noted in the Akt2−/− mice after chronic exposure to normobaric hypoxia (10% O2). Overexpression of the upstream repressor of Akt signaling, phosphatase and tensin homolog deleted on chromosome 10 (PTEN), and conditional and inducible knockout of mTOR in smooth muscle cells were also shown to attenuate the rise in right ventricular systolic pressure and the development of right ventricular hypertrophy. In conclusion, Akt isoforms appear to have a unique function within the pulmonary vasculature, with the Akt1 isoform having a dominant role in pulmonary vascular remodeling associated with HPH. The PTEN/Akt1/mTOR signaling pathway will continue to be a critical area of study in the pathogenesis of pulmonary hypertension, and specific Akt isoforms may help specify therapeutic targets for the treatment of pulmonary hypertension. PMID:25416384
Pulmonary function test in formalin exposed and nonexposed subjects: A comparative study
Uthiravelu, P.; Saravanan, A.; Kumar, C. Kishor; Vaithiyanandane, V.
2015-01-01
Background: The main function of the lung is gas exchange, which can be assessed in several ways. A spirometer measures the flow and the volumes of the inspired and expired air. The thoracic and abdominal muscle strength plays an important role in pulmonary function and diffusing lung capacity. Aims and Objectives: The aim of this study was to assess the effects of formalin exposure on the pulmonary function to compare with healthy individuals. To assess the chronic effects of formalin exposure on Pulmonary function tests (PFTs) in the faculties, lab technicians and attender of the Department of Anatomy and Pathology of SRM Medical Hospital and Research Centre, Kattankulathur. Materials and Methods: This prospective study was carried out in 50 healthy formalin exposed subjects (at least 5 years exposure) from Department of Anatomy and Pathology of SRM Medical College Hospital and Research Centre, Kattankulathur and 50 healthy controls of same age group of this study were included after obtaining ethical clearance and consent ‘Easy One Pro Spirometer (Ndd Medical Technologies, Cheshire SK 101LT, United Kingdom) was used to find out the PFT. Results: Student's t-test was applied to compare the PFT parameters between formalin exposed and formalin nonexposed group. There was a significant difference in mean and standard deviation of pulmonary parameters with the P < 0.005 in formalin exposed, which shows that they have lesser ventilatory drive. Conclusion: The formalin exposed subjects in our study presented with a mixed disorder of both obstructive and restrictive type. We also found that there was a negative correlation of pulmonary function with that of the degree and duration of exposure to formalin. PMID:26015743
NASA Technical Reports Server (NTRS)
West, J. B.; Elliott, A. R.; Guy, H. J.; Prisk, G. K.
1997-01-01
The lung is exquisitely sensitive to gravity, and so it is of interest to know how its function is altered in the weightlessness of space. Studies on National Aeronautics and Space Administration (NASA) Spacelabs during the last 4 years have provided the first comprehensive data on the extensive changes in pulmonary function that occur in sustained microgravity. Measurements of pulmonary function were made on astronauts during space shuttle flights lasting 9 and 14 days and were compared with extensive ground-based measurements before and after the flights. Compared with preflight measurements, cardiac output increased by 18% during space flight, and stroke volume increased by 46%. Paradoxically, the increase in stroke volume occurred in the face of reductions in central venous pressure and circulating blood volume. Diffusing capacity increased by 28%, and the increase in the diffusing capacity of the alveolar membrane was unexpectedly large based on findings in normal gravity. The change in the alveolar membrane may reflect the effects of uniform filling of the pulmonary capillary bed. Distributions of blood flow and ventilation throughout the lung were more uniform in space, but some unevenness remained, indicating the importance of nongravitational factors. A surprising finding was that airway closing volume was approximately the same in microgravity and in normal gravity, emphasizing the importance of mechanical properties of the airways in determining whether they close. Residual volume was unexpectedly reduced by 18% in microgravity, possibly because of uniform alveolar expansion. The findings indicate that pulmonary function is greatly altered in microgravity, but none of the changes observed so far will apparently limit long-term space flight. In addition, the data help to clarify how gravity affects pulmonary function in the normal gravity environment on Earth.
Atluri, Pavan; Fairman, Alexander S.; MacArthur, John W.; Goldstone, Andrew B.; Cohen, Jeffrey E.; Howard, Jessica L.; Zalewski, Christyna M.; Shudo, Yasuhiro; Woo, Y. Joseph
2014-01-01
Background Continuous flow left ventricular assist devices (CF LVAD) are being implanted with increasing frequency for end-stage heart failure. At the time of LVAD implant, a large proportion of patients have pulmonary hypertension, right ventricular (RV) dysfunction, and tricuspid regurgitation (TR). RV dysfunction and TR can exacerbate renal dysfunction, hepatic dysfunction, coagulopathy, edema, and even prohibit isolated LVAD implant. Repairing TR mandates increased cardiopulmonary bypass time and bicaval cannulation, which should be reserved for the time of orthotopic heart transplantation. We hypothesized that CF LVAD implant would improve pulmonary artery pressures, enhance RV function, and minimize TR, obviating need for surgical tricuspid repair. Methods One hundred fourteen continuous flow LVADs implanted from 2005 through 2011 at a single center, with medical management of functional TR, were retrospectively analyzed. Pulmonary artery pressures were measured immediately prior to and following LVAD implant. RV function and TR were graded according to standard echocardiographic criteria, prior to, immediately following, and long-term following LVAD. Results There was a significant improvement in post-VAD mean pulmonary arterial pressures (26.6 ± 4.9 vs. 30.2 ± 7.4 mmHg, p = 0.008) with equivalent loading pressures (CVP = 12.0 ± 4.0 vs. 12.1 ± 5.1 p = NS). RV function significantly improved, as noted by right ventricular stroke work index (7.04 ± 2.60 vs. 6.05 ± 2.54, p = 0.02). There was an immediate improvement in TR grade and RV function following LVAD implant, which was sustained long term. Conclusion Continuous flow LVAD implant improves pulmonary hypertension, RV function, and tricuspid regurgitation. TR may be managed nonoperatively during CF LVAD implant. PMID:24118109
Pulmonary vasodilation in acute and chronic heart failure: empiricism and evidence.
Guglin, Maya
2011-09-01
Pulmonary hypertension in heart failure is associated with exercise intolerance and adverse outcomes. With the availability of multiple drugs that cause pulmonary vasodilation and decrease pulmonary arterial pressure, pulmonary hypertension becomes an attractive therapeutic target. Out of several classes of medications, oral phosphodiesterase inhibitors emerge as the most promising in terms of symptomatic improvement, hemodynamic benefits, reverse cardiac remodeling, and functional capacity. Future trials will show whether the use of these drugs translates to decreased morbidity and mortality in heart failure.
CFTR gene variant IVS8-5T in disseminated bronchiectasis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pignatti, P.F.; Bombieri, C.; Benetazzo, M.
1996-04-01
Obstructive pulmonary disease includes asthma, chronic obstructive pulmonary disease (COPD; i.e., pulmonary emphysema and chronic bronchitis), bronchiectasis, and cystic fibrosis (CF). It represents a leading cause of death in developed countries. Both familial clustering of non-CF obstructive pulmonary disease and familial aggregation of impaired lung function have been described. This suggests that genetic factors contribute to non-CF obstructive pulmonary disease, even if it is difficult to determine the relative contribution of environmental factors. 11 refs., 1 tab.
Pulmonary hypertension in older adults.
McArdle, John R; Trow, Terence K; Lerz, Kathryn
2007-12-01
Pulmonary hypertension is a frequently encountered problem in older patients. True idiopathic pulmonary arterial hypertension can also be seen and requires careful exclusion in older patients. Institution of therapies must be tempered with an appreciation of individual comorbidities and functional limitations that may affect patients' ability to comply and benefit from the complex treatments available for pulmonary arterial hypertension. This article reviews the existing data on the various forms of pulmonary hypertension presenting in older patients and on appropriate therapy in this challenging population.
Smargiassi, Audrey; Goldberg, Mark S; Wheeler, Amanda J; Plante, Céline; Valois, Marie-France; Mallach, Gary; Kauri, Lisa Marie; Shutt, Robin; Bartlett, Susan; Raphoz, Marie; Liu, Ling
2014-07-01
The acute cardiorespiratory effects of air quality among children living in areas with considerable heavy industry have not been well investigated. We conducted a panel study of children with asthma living in proximity to an industrial complex housing two refineries in Montreal, Quebec, in order to assess associations between their personal daily exposure to air pollutants and changes in pulmonary function and selected indicators of cardiovascular health. Seventy-two children with asthma age 7-12 years in 2009-2010 participated in this panel study for a period of 10 consecutive days. They carried a small backpack for personal monitoring of sulphur dioxide (SO2), benzene, fine particles (PM2.5), nitrogen dioxide (NO2) and polycyclic aromatic hydrocarbons (PAHs) and underwent daily spirometry and cardiovascular testing (blood pressure, pulse rate and oxygen saturation). To estimate these associations, we used mixed regression models, adjusting for within-subject serial correlation, and for the effects of a number of personal and environmental variables (e.g., medication use, ethnicity, temperature). Children with asthma involved in the study had relatively good pulmonary function test results (mean FEV1 compared to standard values: 89.8%, mean FVC: 97.6%, mean FEF25-75: 76.3%). Median diastolic, systolic blood pressures and oxygen saturation were 60/94 mmHg and 99%, respectively. Median personal concentrations of pollutants were NO2, 5.5 ppb; benzene, 2.1 µg/m(3); PM2.5, 5.7 µg/m(3); and total PAH, 130 µg/m(3). Most personal concentrations of SO2 were below the level of detection. No consistent associations were observed between cardio-pulmonary indices and personal exposure to PM2.5, NO2 and benzene, although there was a suggestion for a small decrease in respiratory function with total concentrations of PAHs (e.g., adjusted association with FVC: -9.9 ml per interquartile range 95%CI: -23.4, 3.7). This study suggests that at low daily average levels of exposure to industrial emissions, effects on pulmonary and cardiovascular functions in children with asthma may be difficult to detect over 10 consecutive days. Copyright © 2014 Elsevier Inc. All rights reserved.
Hunter, Kendall S; Lee, Po-Feng; Lanning, Craig J; Ivy, D Dunbar; Kirby, K Scott; Claussen, Lori R; Chan, K Chen; Shandas, Robin
2008-01-01
Pulmonary vascular resistance (PVR) is the current standard for evaluating reactivity in children with pulmonary arterial hypertension (PAH). However, PVR measures only the mean component of right ventricular afterload and neglects pulsatile effects. We recently developed and validated a method to measure pulmonary vascular input impedance, which revealed excellent correlation between the zero harmonic impedance value and PVR and suggested a correlation between higher-harmonic impedance values and pulmonary vascular stiffness. Here we show that input impedance can be measured routinely and easily in the catheterization laboratory, that impedance provides PVR and pulmonary vascular stiffness from a single measurement, and that impedance is a better predictor of disease outcomes compared with PVR. Pressure and velocity waveforms within the main pulmonary artery were measured during right heart catheterization of patients with normal pulmonary artery hemodynamics (n = 14) and those with PAH undergoing reactivity evaluation (49 subjects, 95 conditions). A correction factor needed to transform velocity into flow was obtained by calibrating against cardiac output. Input impedance was obtained off-line by dividing Fourier-transformed pressure and flow waveforms. Exceptional correlation was found between the indexed zero harmonic of impedance and indexed PVR (y = 1.095x + 1.381, R2 = 0.9620). In addition, the modulus sum of the first 2 harmonics of impedance was found to best correlate with indexed pulse pressure over stroke volume (y = 13.39x - 0.8058, R2 = 0.7962). Among a subset of patients with PAH (n = 25), cumulative logistic regression between outcomes to total indexed impedance was better (R(L)2 = 0.4012) than between outcomes and indexed PVR (R(L)2 = 0.3131). Input impedance can be consistently and easily obtained from pulse-wave Doppler and a single catheter pressure measurement, provides comprehensive characterization of the main components of RV afterload, and better predicts patient outcomes compared with PVR alone.
... Visit Children and Clinical Studies to hear experts, parents, and children talk about their experiences with clinical ... Pneumonitis Idiopathic Pulmonary Fibrosis Pneumonia Pulmonary Function ...
Crisafulli, Ernesto; Scelfo, Chiara; Tzani, Panagiota; Aiello, Marina; Bertorelli, Giuseppina; Chetta, Alfredo
2017-06-01
Background Silent/asymptomatic peripheral artery disease may occur in patients with chronic obstructive pulmonary disease, but it is poorly investigated. The primary aim of this study was to evaluate in chronic obstructive pulmonary disease patients the impact of asymptomatic/silent peripheral artery disease on maximal exercise capacity; the secondary aim was to search for predictors of peripheral artery disease. Methods We prospectively enrolled chronic obstructive pulmonary disease outpatients. Data on anthropometric characteristics, lung function, cardiopulmonary exercise test and ankle-brachial index were recorded. The cut-off of ankle-brachial index used to define patients with peripheral artery disease was ≤0.90. Results We studied 47 patients and found 24 patients (51%) who showed peripheral artery disease. As compared to patients without peripheral artery disease, patients with peripheral artery disease had lower values of peak oxygen uptake, peak workload, energy expenditure (metabolic equivalents) and heart rate recovery, but showed the same degree of airflow obstruction and static and dynamic hyperinflation. In a multivariate linear regression model performed to identify variables predicting metabolic equivalents, ankle-brachial index (β 2.59; 95% confidence interval 0.51-4.67; p = 0.016) was an independent variable. In the search for predictors of peripheral artery disease, heart rate recovery (odds ratio 8.80; 95% confidence interval 1.30-59.35; p = 0.026) increased the risk of peripheral artery disease, whereas metabolic equivalents (odds ratio 0.50; 95% confidence interval 0.26-0.94, p = 0.033) and inhaled corticosteroids+long-acting β 2 agonists (odds ratio 0.13; 95% confidence interval 0.02-0.83; p = 0.030) reduced this risk. Conclusions In chronic obstructive pulmonary disease outpatients, asymptomatic/silent peripheral artery disease affects the maximal exercise capacity regardless of airflow obstruction and lung hyperinflation. A delay of heart rate recovery increase the risk of peripheral artery disease, whereas high values of metabolic equivalents and the use of inhaled corticosteroids+long-acting β 2 agonists reduces this risk.
Cardiovascular and pulmonary dynamics by quantitative imaging
NASA Technical Reports Server (NTRS)
Wood, E. H.
1976-01-01
The accuracy and range of studies on cardiovascular and pulmonary functions can be greatly facilitated if the motions of the underlying organ systems throughout individual cycles can be directly visualized and readily measured with minimum or preferably no effect on these motions. Achievement of this objective requires development of techniques for quantitative noninvasive or minimally invasive dynamic and stop-action imaging of the organ systems. A review of advances in dynamic quantitative imaging of moving organs reveals that the revolutionary value of cross-sectional and three-dimensional images produced by various types of radiant energy such as X-rays and gamma rays, positrons, electrons, protons, light, and ultrasound for clinical diagnostic and biomedical research applications is just beginning to be realized. The fabrication of a clinically useful cross-section reconstruction device with sensing capabilities for both anatomical structural composition and chemical composition may be possible and awaits future development.
[Lung dysfunction in patients with severe chronic obstructive bronchitis].
Nefedov, V B; Popova, L A; Shergina, E A
2005-01-01
VC, FVC, FEV1, FEV1/VC%, PEF, MEF25, MEF50, MEF75, TCL, TGV, RV, Raw, Rin, Rex, DLCO-SS, PaO2, and PaCO2 were determined in 36 patients with severe chronic obstructive lung disease (FEV1 < 50% of the normal value). All the patients were found to have impaired bronchial patency and changes in lung volumes and capacities; 83.3% of the patients had pulmonary gas exchange dysfunction. Impaired bronchial patency mainly appeared as decreased FEV1, FEV1/VC%, PEF, MEF25, MEF50, MEF75, Raw, Rin, Rex; altered lung volumes and capacities manifested by increased RV, TGV, and TLC, and by decreased VC and FVC; pulmonary gas exchange dysfunction showed up as lowered PaO2 and DLCO-SS, as decreased or increased PaCO2. The observed bronchial patency disorders varied from significant to severe; functional changes in lung volumes and capacities were mild to severe.
Wyss, Annah B; House, John S; Hoppin, Jane A; Richards, Marie; Hankinson, John L; Long, Stuart; Henneberger, Paul K; Beane Freeman, Laura E; Sandler, Dale P; O'Connell, Elizabeth Long; Cummings, Christie Barker; Umbach, David M; London, Stephanie J
2018-03-01
Literature suggests that early exposure to the farming environment protects against atopy and asthma; few studies have examined pulmonary function. We evaluated associations between early-life farming exposures and pulmonary function in 3061 adults (mean age=63) from a US farming population using linear regression. Childhood raw milk consumption was associated with higher FEV 1 (β=49.5 mL, 95% CI 2.8 to 96.1 mL, p=0.04) and FVC (β=66.2 mL, 95% CI 13.2 to 119.1 mL, p=0.01). We did not find appreciable associations with other early-life farming exposures. We report a novel association between raw milk consumption and higher pulmonary function that lasts into older adulthood. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Weiss, Gertraud; Steinacher, Ina; Lamprecht, Bernd; Kaiser, Bernhard; Mikes, Romana; Sator, Lea; Hartl, Sylvia; Wagner, Helga; Studnicka, M
2017-01-26
Chronic obstructive pulmonary disease prevalence rates are still high. However, the majority of subjects are not diagnosed. Strategies have to be implemented to overcome the problem of under-diagnosis. Questionnaires could be used to pre-select subjects for spirometry and thereby help reducing under-diagnosis. We report a brief, simple, self-administrable and validated chronic obstructive pulmonary disease questionnaire to increase the pre-test probability for chronic obstructive pulmonary disease diagnosis in subjects undergoing confirmatory spirometry. In 2005, we completed the Austrian Burden of Obstructive Lung Disease-study in 1258 subjects aged >40 years. Post-bronchodilator spirometry was performed, and non-reversible airflow limitation defined by FEV 1 /FVC ratio below the lower limit of normal. Questions from the Salzburg chronic obstructive pulmonary disease screening-questionnaire were selected using a logistic regression model, and risk scores were based on regression-coefficients. A training sub-sample (n = 800) was used to create the score, and a test sub-sample (n = 458) was used to test it. In 2008, an external validation study was done, using the same protocol in 775 patients from primary care. The Salzburg chronic obstructive pulmonary disease screening questionnaire was composed of items related to "breathing problems", "wheeze", "cough", "limitation of physical activity", and "smoking". At the >=2 points cut-off of the Salzburg chronic obstructive pulmonary disease screening questionnaire, sensitivity was 69.1% [95%CI: 56.6%; 79.5%], specificity 60.0% [95%CI: 54.9%; 64.9%], the positive predictive value 23.2% [95%CI: 17.7%; 29.7%] and the negative predictive value 91.8% [95%CI: 87.5%; 95.7%] to detect post bronchodilator airflow limitation. The external validation study in primary care confirmed these findings. The Salzburg chronic obstructive pulmonary disease screening questionnaire was derived from the highly standardized Burden of Obstructive Lung Disease study. This validated and easy to use questionnaire can help to increase the efficiency of chronic obstructive pulmonary disease case-finding. QUESTIONNAIRE FOR PRE-SCREENING POTENTIAL SUFFERERS: Scientists in Austria have developed a brief, simple questionnaire to identify patients likely to have early-stage chronic lung disease. Chronic obstructive pulmonary disease (COPD) is notoriously difficult to diagnose, and the condition often causes irreversible lung damage before it is identified. Finding a simple, cost-effective method of pre-screening patients with suspected early-stage COPD could potentially improve treatment responses and limit the burden of extensive lung function ('spirometry') tests on health services. Gertraud Weiss at Paracelsus Medical University, Austria, and co-workers have developed and validated an easy-to-use, self-administered questionnaire that could prove effective for pre-screening patients. The team trialed the five-point Salzburg COPD-screening questionnaire on 1258 patients. Patients scoring 2 points or above on the questionnaire underwent spirometry tests. The questionnaire seems to provide a sensitive and cost-effective way of pre-selecting patients for spirometry referral.
[Formation of treatment motivation in patients with pulmonary tuberculosis].
Lebedeva, N O; Sukhova, E V
2006-01-01
Incompliance is a reason for inefficient therapy in patients with pulmonary tuberculosis. The purpose of the investigation was to study the values in patients with pulmonary tuberculosis and, on their basis, to form treatment motivation. A special questionnaire (the authors' innovation) was drawn up and used to examine 129 tuberculosis patients, Samara residents, aged 18 to 65 years. The results were statistically processes, by using the SPSS program, version 10.0. The patients from different sociomedical groups, who received therapy of varying duration, were found to have different personality values. Therefore, different treatment motivations should be used to increase compliance. The most governing motives were identified for tuberculosis patients from different sociomedical groups.
Gerritsen, M G; Willemink, M J; Pompe, E; van der Bruggen, T; van Rhenen, A; Lammers, J W J; Wessels, F; Sprengers, R W; de Jong, P A; Minnema, M C
2017-01-01
We performed a prospective study in patients with chemotherapy induced febrile neutropenia to investigate the diagnostic value of low-dose computed tomography compared to standard chest radiography. The aim was to compare both modalities for detection of pulmonary infections and to explore performance of low-dose computed tomography for early detection of invasive fungal disease. The low-dose computed tomography remained blinded during the study. A consensus diagnosis of the fever episode made by an expert panel was used as reference standard. We included 67 consecutive patients on the first day of febrile neutropenia. According to the consensus diagnosis 11 patients (16.4%) had pulmonary infections. Sensitivity, specificity, positive predictive value and negative predictive value were 36%, 93%, 50% and 88% for radiography, and 73%, 91%, 62% and 94% for low-dose computed tomography, respectively. An uncorrected McNemar showed no statistical difference (p = 0.197). Mean radiation dose for low-dose computed tomography was 0.24 mSv. Four out of 5 included patients diagnosed with invasive fungal disease had radiographic abnormalities suspect for invasive fungal disease on the low-dose computed tomography scan made on day 1 of fever, compared to none of the chest radiographs. We conclude that chest radiography has little value in the initial assessment of febrile neutropenia on day 1 for detection of pulmonary abnormalities. Low-dose computed tomography improves detection of pulmonary infiltrates and seems capable of detecting invasive fungal disease at a very early stage with a low radiation dose.