Effect of baroreceptor denervation on the autonomic control of arterial pressure in conscious mice.
Rodrigues, Fernanda Luciano; de Oliveira, Mauro; Salgado, Helio Cesar; Fazan, Rubens
2011-09-01
This study evaluated the role of arterial baroreceptors in arterial pressure (AP) and pulse interval (PI) regulation in conscious C57BL mice. Male animals, implanted with catheters in a femoral artery and a jugular vein, were submitted to sino-aortic (SAD), aortic (Ao-X) or carotid sinus denervation (Ca-X), 5 days prior to the experiments. After basal recording of AP, the lack of reflex bradycardia elicited by administration of phenylephrine was used to confirm the efficacy of SAD, and cardiac autonomic blockade with methylatropine and propranolol was performed. The AP and PI variability were calculated in the time and frequency domains (spectral analysis/fast Fourier transform) with the spectra quantified in low- (LF; 0.25-1 Hz) and high-frequency bands (HF; 1-5 Hz). Basal AP and AP variability were higher after SAD, Ao-X or Ca-X than in intact mice. Pulse interval was similar among the groups, whereas PI variability was lower after SAD. Atropine elicited a slight tachycardia in control mice but did not change PI after total or partial denervation. The bradycardia caused by propranolol was higher after SAD, Ao-X or Ca-X compared with intact mice. The increase in the variability of AP was accompanied by a marked increase in the LF and HF power of the AP spectra after baroreceptor denervation. The LF and HF power of the PI were reduced by SAD and by Ao-X or Ca-X. Therefore, both sino-aortic and partial baroreceptor denervation in mice elicits hypertension and a remarkable increase in AP variability and cardiac sympathetic tonus. Spectral analysis showed an important contribution of the baroreflex in the power of LF oscillations of the PI spectra. Both sets of baroreceptors seem to be equally important in the autonomic regulation of the cardiovascular system in mice.
Hemodynamic changes in post-suspension rats during gradual hemorrhage
NASA Astrophysics Data System (ADS)
Vinogradova, O. L.; Borovik, A. S.; Tsvirkoun, D. V.; Tarasova, O. S.
2005-08-01
In urethane-anasthetized rats the effects of 2-week tail suspension upon the hemodynamic changes during simulated orthostatism and during loss of blood were studied. Baseline values of mean arterial pressure (MAP) and pulse interval (PI) did not differ in cage control (C) and post-suspension rats (TS). In both groups 45o head-up tilt resulted in prominent decline of MAP. In C group this effect was followed by the compensatory phase, which was virtually lost in TS group. No significant postural changes of PI were observed. Gradual hemorrhage (30% blood loss during 30 min) resulted in similar MAP drop in C and TS (up to 40% of baseline level). Along with that, PI increase was less prominent in TS (25%) compared to C (60%) indicating higher resistance of the heart to hypovolemia after suspension.
Yin, Shengyong; Chen, Xinhua; Xie, Haiyang; Zhou, Lin; Guo, Danjing; Xu, Yuning; Wu, Liming; Zheng, Shusen
2016-08-15
Previous studies showed nanosecond pulsed electric field (nsPEF) can ablate solid tumors including hepatocellular carcinoma (HCC) but its effect on cell membrane is not fully understood. We hypothesized nsPEF disrupt the microdomains on outer-cellular membrane with direct mechanical force and as a result the plasma membrane permeability increases to facilitate the small molecule intake. Three HCC cells were pulsed one pulse per minute, an interval longer than nanopore resealing time. The cationized ferritin was used to mark up the electronegative microdomains, propidium iodide (PI) for membrane permeabilization, energy dispersive X-ray spectroscopy (EDS) for the negative cell surface charge and cisplatin for inner-cellular cytotoxicity. We demonstrated that the ferritin marked-microdomain and negative cell surface charge were disrupted by nsPEF caused-mechanical force. The cell uptake of propidium and cytotoxicity of DNA-targeted cisplatin increased with a dose effect. Cisplatin gains its maximum inner-cellular cytotoxicity when combining with nsPEF stimulation. We conclude that nsPEF disrupt the microdomains on the outer cellular membrane directly and increase the membrane permeabilization for PI and cisplatin. The microdomain disruption and membrane infiltration changes are caused by the mechanical force from the changes of negative cell surface charge. Copyright © 2016 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yin, Shengyong; Chen, Xinhua; Xie, Haiyang
Previous studies showed nanosecond pulsed electric field (nsPEF) can ablate solid tumors including hepatocellular carcinoma (HCC) but its effect on cell membrane is not fully understood. We hypothesized nsPEF disrupt the microdomains on outer-cellular membrane with direct mechanical force and as a result the plasma membrane permeability increases to facilitate the small molecule intake. Three HCC cells were pulsed one pulse per minute, an interval longer than nanopore resealing time. The cationized ferritin was used to mark up the electronegative microdomains, propidium iodide (PI) for membrane permeabilization, energy dispersive X-ray spectroscopy (EDS) for the negative cell surface charge and cisplatinmore » for inner-cellular cytotoxicity. We demonstrated that the ferritin marked-microdomain and negative cell surface charge were disrupted by nsPEF caused-mechanical force. The cell uptake of propidium and cytotoxicity of DNA-targeted cisplatin increased with a dose effect. Cisplatin gains its maximum inner-cellular cytotoxicity when combining with nsPEF stimulation. We conclude that nsPEF disrupt the microdomains on the outer cellular membrane directly and increase the membrane permeabilization for PI and cisplatin. The microdomain disruption and membrane infiltration changes are caused by the mechanical force from the changes of negative cell surface charge.« less
Effect of low-sodium diet on uteroplacental circulation.
Delemarre, F M; van Leest, L A; Jongsma, H W; Steegers, E A
2000-01-01
To study the influence of chronic dietary sodium restriction on uteroplacental circulation. In a randomized trial, Doppler flow velocity waveforms of the uterine and umbilical artery were studied at monthly intervals during pregnancy in 59 women on a low-sodium diet and in 68 controls. Pulsatility index (PI), resistance index (RI), and A/B ratio of the uterine artery were significantly lower during sodium restriction, whereas PI, RI, and A/B ratio of the umbilical artery were significantly higher. The lower resistance indices of the uterine artery during sodium restriction might reflect an increase in pulse pressure/impedance ratio as a result of activation of the renin-angiotensin system. The increase in umbilical artery resistance indices supports the hypothesis that fetal circulation might be altered by chronic dietary sodium restriction.
Herbst, Elizabeth; Unnikrishnan, Sunil; Wang, Shiying; Klibanov, Alexander L.; Hossack, John A.; Mauldin, F. William
2016-01-01
Objectives The use of ultrasound imaging for cancer diagnosis and screening can be enhanced with the use of molecularly targeted microbubbles. Nonlinear imaging strategies such as pulse inversion (PI) and “contrast pulse sequences” (CPS) can be used to differentiate microbubble signal, but often fail to suppress highly echogenic tissue interfaces. This failure results in false positive detection and potential misdiagnosis. In this study, a novel Acoustic Radiation Force (ARF) based approach was developed for superior microbubble signal detection. The feasibility of this technique, termed ARF-decorrelation-weighted PI (ADW-PI), was demonstrated in vivo using a subcutaneous mouse tumor model. Materials and Methods Tumors were implanted in the hindlimb of C57BL/6 mice by subcutaneous injection of MC38 cells. Lipid-shelled microbubbles were conjugated to anti-VEGFR2 antibody and administered via bolus injection. An image sequence using ARF pulses to generate microbubble motion was combined with PI imaging on a Verasonics Vantage programmable scanner. ADW-PI images were generated by combining PI images with inter-frame signal decorrelation data. For comparison, CPS images of the same mouse tumor were acquired using a Siemens Sequoia clinical scanner. Results Microbubble-bound regions in the tumor interior exhibited significantly higher signal decorrelation than static tissue (n = 9, p < 0.001). The application of ARF significantly increased microbubble signal decorrelation (n = 9, p < 0.01). Using these decorrelation measurements, ADW-PI imaging demonstrated significantly improved microbubble contrast-to-tissue ratio (CTR) when compared to corresponding CPS or PI images (n = 9, p < 0.001). CTR improved with ADW-PI by approximately 3 dB compared to PI images and 2 dB compared to CPS images. Conclusions Acoustic radiation force can be used to generate adherent microbubble signal decorrelation without microbubble bursting. When combined with pulse inversion, measurements of the resulting microbubble signal decorrelation can be used to reconstruct images that exhibit superior suppression of highly echogenic tissue interfaces when compared to PI or CPS alone. PMID:27495188
Baseband pulse shaping for pi /4 FQPSK in nonlinearly amplified mobile channels
NASA Astrophysics Data System (ADS)
Subasinghe-Dias, Dileeka; Feher, Kamilo
1994-10-01
We apply baseband pulse shaping techniques for pi /4 QPSK in order to reduce the spectral regeneration of the bandlimited carrier after nonlinear amplification. These Feher's patented techniques, namely, pi /4 FQPSK (superposed QPSK) and pi /4 CTPSK (controlled transition PSK), may also be noncoherently demodulated. Application of these techniques is in fast fading, power efficient channels, typical of the mobile radio environment. Patents related to FQPSK are described. Computer simulation and experimental studies demonstrate that with these baseband waveshaping techniques, carrier envelope fluctuations are significantly reduced, and the out-of-band power after nonlinear amplification is suppressed by up to 20 dB compared to pi /4 QPSK. In frequency noninterleaved land or satellite mobile radio systems operating in a nonlinear, fading and ACI (adjacent channel interference) environment, these techniques may achieve 20%-50% higher spectral efficiency compared to pi /4 QPSK. In mobile cellular systems using pi /4 QPSK, such as the new North American and the Japanese digital cellular systems, the application of these baseband pulse shapes may allow more convenient and less costly amplifier linearization.
Numerical modeling of Harmonic Imaging and Pulse Inversion fields
NASA Astrophysics Data System (ADS)
Humphrey, Victor F.; Duncan, Tracy M.; Duck, Francis
2003-10-01
Tissue Harmonic Imaging (THI) and Pulse Inversion (PI) Harmonic Imaging exploit the harmonics generated as a result of nonlinear propagation through tissue to improve the performance of imaging systems. A 3D finite difference model, that solves the KZK equation in the frequency domain, is used to investigate the finite amplitude fields produced by rectangular transducers driven with short pulses and their inverses, in water and homogeneous tissue. This enables the characteristic of the fields and the effective PI field to be calculated. The suppression of the fundamental field in PI is monitored, and the suppression of side lobes and a reduction in the effective beamwidth for each field are calculated. In addition, the differences between the pulse and inverse pulse spectra resulting from the use of very short pulses are noted, and the differences in the location of the fundamental and second harmonic spectral peaks observed.
Herbst, Elizabeth B; Unnikrishnan, Sunil; Wang, Shiying; Klibanov, Alexander L; Hossack, John A; Mauldin, Frank William
2017-02-01
The use of ultrasound imaging for cancer diagnosis and screening can be enhanced with the use of molecularly targeted microbubbles. Nonlinear imaging strategies such as pulse inversion (PI) and "contrast pulse sequences" (CPS) can be used to differentiate microbubble signal, but often fail to suppress highly echogenic tissue interfaces. This failure results in false-positive detection and potential misdiagnosis. In this study, a novel acoustic radiation force (ARF)-based approach was developed for superior microbubble signal detection. The feasibility of this technique, termed ARF decorrelation-weighted PI (ADW-PI), was demonstrated in vivo using a subcutaneous mouse tumor model. Tumors were implanted in the hindlimb of C57BL/6 mice by subcutaneous injection of MC38 cells. Lipid-shelled microbubbles were conjugated to anti-VEGFR2 antibody and administered via bolus injection. An image sequence using ARF pulses to generate microbubble motion was combined with PI imaging on a Verasonics Vantage programmable scanner. ADW-PI images were generated by combining PI images with interframe signal decorrelation data. For comparison, CPS images of the same mouse tumor were acquired using a Siemens Sequoia clinical scanner. Microbubble-bound regions in the tumor interior exhibited significantly higher signal decorrelation than static tissue (n = 9, P < 0.001). The application of ARF significantly increased microbubble signal decorrelation (n = 9, P < 0.01). Using these decorrelation measurements, ADW-PI imaging demonstrated significantly improved microbubble contrast-to-tissue ratio when compared with corresponding CPS or PI images (n = 9, P < 0.001). Contrast-to-tissue ratio improved with ADW-PI by approximately 3 dB compared with PI images and 2 dB compared with CPS images. Acoustic radiation force can be used to generate adherent microbubble signal decorrelation without microbubble bursting. When combined with PI, measurements of the resulting microbubble signal decorrelation can be used to reconstruct images that exhibit superior suppression of highly echogenic tissue interfaces when compared with PI or CPS alone.
2012-01-30
calculated action exceeded 1.7 MA2 -s. Preliminary efforts on high voltage diode interconnection have produced quarter wafer interconnected PiN...was packaged in a “hockey-puck” configuration and pulsed to 64 kA, dissipating 382 J with a calculated action exceeding 1.7 MA2 -s. II. FULL...epitaxial layers are utilized. 11.72-cm2 Active-area Wafer Interconnected PiN Diode pulsed at 64 kA dissipates 382 J and exhibits an action of 1.7 MA2 -s
NASA Astrophysics Data System (ADS)
Ibey, Bennett L.; Roth, Caleb C.; Bernhard, Joshua A.; Pakhomov, Andrei G.; Wilmink, Gerald J.; Pakhomova, Olga
2011-03-01
Intense, nanosecond-duration electric pulses (nsEP) have been introduced as a novel modality to alter cellular function, with a mechanism of action qualitatively different from micro- and millisecond duration pulses used in electroporation. In this study, we determined the thresholds for plasma membrane injury (within 15 minutes) and cell death (at 24 hours) for 4 different cell types (CHO-K1, HeLa, Jurkat and U937). Plasma membrane injury was measured by flow cytometry using two fluorescent dyes, namely Annexin V-FITC, which binds to phosphatidylserine (PS) upon its externalization (subtle membrane injury), and propidium iodide (PI), which is typically impermeable to the cell, but enters when large pores are formed in the plasma membrane. In all cell types, 10-ns pulses caused phosphatidylserine (PS) externalization at low doses (<150kV/cm and 100 pulses for each cell type) and no PI uptake. Jurkat and U937 cell lines showed substantial cell death without uptake of PI (15 minutes post exposure) suggesting either delayed permeabilization due to swelling, or damage to intracellular components. In CHO-K1 and HeLa cell lines, PI uptake occurred at low doses relative to that necessary to cause cell death suggesting a necrotic death similar to longer pulse exposures. These findings suggest that nanosecond pulses may be beneficial in applications that require selective elimination of specific cell types.
Enhancing Heart-Beat-Based Security for mHealth Applications.
Seepers, Robert M; Strydis, Christos; Sourdis, Ioannis; De Zeeuw, Chris I
2017-01-01
In heart-beat-based security, a security key is derived from the time difference between consecutive heart beats (the inter-pulse interval, IPI), which may, subsequently, be used to enable secure communication. While heart-beat-based security holds promise in mobile health (mHealth) applications, there currently exists no work that provides a detailed characterization of the delivered security in a real system. In this paper, we evaluate the strength of IPI-based security keys in the context of entity authentication. We investigate several aspects that should be considered in practice, including subjects with reduced heart-rate variability (HRV), different sensor-sampling frequencies, intersensor variability (i.e., how accurate each entity may measure heart beats) as well as average and worst-case-authentication time. Contrary to the current state of the art, our evaluation demonstrates that authentication using multiple, less-entropic keys may actually increase the key strength by reducing the effects of intersensor variability. Moreover, we find that the maximal key strength of a 60-bit key varies between 29.2 bits and only 5.7 bits, depending on the subject's HRV. To improve security, we introduce the inter-multi-pulse interval (ImPI), a novel method of extracting entropy from the heart by considering the time difference between nonconsecutive heart beats. Given the same authentication time, using the ImPI for key generation increases key strength by up to 3.4 × (+19.2 bits) for subjects with limited HRV, at the cost of an extended key-generation time of 4.8 × (+45 s).
Nonlinear pulse compression in pulse-inversion fundamental imaging.
Cheng, Yun-Chien; Shen, Che-Chou; Li, Pai-Chi
2007-04-01
Coded excitation can be applied in ultrasound contrast agent imaging to enhance the signal-to-noise ratio with minimal destruction of the microbubbles. Although the axial resolution is usually compromised by the requirement for a long coded transmit waveforms, this can be restored by using a compression filter to compress the received echo. However, nonlinear responses from microbubbles may cause difficulties in pulse compression and result in severe range side-lobe artifacts, particularly in pulse-inversion-based (PI) fundamental imaging. The efficacy of pulse compression in nonlinear contrast imaging was evaluated by investigating several factors relevant to PI fundamental generation using both in-vitro experiments and simulations. The results indicate that the acoustic pressure and the bubble size can alter the nonlinear characteristics of microbubbles and change the performance of the compression filter. When nonlinear responses from contrast agents are enhanced by using a higher acoustic pressure or when more microbubbles are near the resonance size of the transmit frequency, higher range side lobes are produced in both linear imaging and PI fundamental imaging. On the other hand, contrast detection in PI fundamental imaging significantly depends on the magnitude of the nonlinear responses of the bubbles and thus the resultant contrast-to-tissue ratio (CTR) still increases with acoustic pressure and the nonlinear resonance of microbubbles. It should be noted, however, that the CTR in PI fundamental imaging after compression is consistently lower than that before compression due to obvious side-lobe artifacts. Therefore, the use of coded excitation is not beneficial in PI fundamental contrast detection.
NASA Technical Reports Server (NTRS)
Rhim, W. K.; Burum, D. P.; Elleman, D. D.
1977-01-01
Adiabatic demagnetization (ADRF) can be achieved in a dipolar coupled nuclear spin system in solids by applying a string of short RF pulses and gradually modulating the pulse amplitudes or pulse angles. This letter reports an adiabatic inverse polarization effect in solids and a rotary spin echo phenomenon observed in liquids when the pulse angle is gradually changed across integral multiples of pi during a string of RF pulses. The RF pulse sequence used is illustrated along with the NMR signal from a CaF2 single crystal as observed between the RF pulses and the rotary spin echo signal observed in liquid C6F6 for n = 2. The observed effects are explained qualitatively on the basis of average Hamiltonian theory.
40 CFR 60.685 - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... average of three glass pull rate (Pi) determinations taken at intervals of at least 30 minutes during each run. The individual glass pull rates (Pi) shall be computed using the following equation: Pi = K′ Ls Wm M [1.0−(LOI/100)] where: Pi = glass pull rate at interval “i”, Mg/hr (ton/hr). Ls = line speed, m...
40 CFR 60.685 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... average of three glass pull rate (Pi) determinations taken at intervals of at least 30 minutes during each run. The individual glass pull rates (Pi) shall be computed using the following equation: Pi=K′ Ls Wm M [1.0−(LOI/100)] where: Pi=glass pull rate at interval “i”, Mg/hr (ton/hr). Ls=line speed, m/min...
40 CFR 60.685 - Test methods and procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... average of three glass pull rate (Pi) determinations taken at intervals of at least 30 minutes during each run. The individual glass pull rates (Pi) shall be computed using the following equation: Pi=K′ Ls Wm M [1.0−(LOI/100)] where: Pi=glass pull rate at interval “i”, Mg/hr (ton/hr). Ls=line speed, m/min...
40 CFR 60.685 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... average of three glass pull rate (Pi) determinations taken at intervals of at least 30 minutes during each run. The individual glass pull rates (Pi) shall be computed using the following equation: Pi=K′ Ls Wm M [1.0−(LOI/100)] where: Pi=glass pull rate at interval “i”, Mg/hr (ton/hr). Ls=line speed, m/min...
40 CFR 60.685 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... average of three glass pull rate (Pi) determinations taken at intervals of at least 30 minutes during each run. The individual glass pull rates (Pi) shall be computed using the following equation: Pi=K′ Ls Wm M [1.0−(LOI/100)] where: Pi=glass pull rate at interval “i”, Mg/hr (ton/hr). Ls=line speed, m/min...
Isotope separation apparatus and method
Cotter, Theodore P.
1982-12-28
The invention relates to a method and apparatus for laser isotope separation by photodeflection. A molecular beam comprising at least two isotopes to be separated intersects, preferable substantially perpendicular to one broad side of the molecular beam, with a laser beam traveling in a first direction. The laser beam is reflected back through the molecular beam, preferably in a second direction essentially opposite to the first direction. The laser beam comprises .pi.-pulses of a selected wavelength which excite unexcited molecules, or cause stimulated emission of excited molecules of one of the isotopes. Excitation caused by first direction .pi.-pulses moves molecules of the isotope excited thereby in the first direction. Stimulated emission of excited molecules of the isotope is brought about by returning .pi.-pulses traveling in the second direction. Stimulated emission moves emitting molecules in a direction opposite to the photon emitted. Because emitted photons travel in the second direction, emitting molecules move in the first direction. Substantial molecular movement is accomplished by a large number of .pi.-pulse-molecule interactions. A beam corer collects the molecules in the resulting enriched divergent portions of the beam.
Effect of lingual gauze swab placement on pulse oximeter readings in anaesthetised dogs and cats.
Mair, A; Martinez-Taboada, F; Nitzan, M
2017-01-14
This study aimed to evaluate the effect of lingual gauze swab placement on pulse oximeter readings in anaesthetised dogs and cats. Following anaesthetic induction, the following pulse oximeter probe configurations were performed: no gauze swab (control), placement of a gauze swab between the tongue and the probe, placement of different thicknesses of gauze swab, placement of red cotton fabric, placement of a sheet of white paper and placement of the probe and gauze swab on different locations on the tongue. Oxygen saturation (SpO 2 ) and peripheral perfusion index (PI) were recorded. Placement of a gauze swab between the pulse oximeter probe and the tongue in anaesthetised dogs and cats resulted in significantly higher SpO 2 values compared with the control group. In dogs, PI values were significantly higher than the control in all groups except the quarter thickness swab group. In cats, PI was significantly higher in the double thickness swab and white paper groups compared with the control. Cats had significantly higher SpO 2 and lower PI values than dogs. The authors propose that increased contact pressure is responsible for significantly higher SpO 2 and PI readings with the use of a lingual gauze swab resulting from changes in transmural pressure and arterial compliance. British Veterinary Association.
Yoshizawa, Shin; Matsuura, Keiko; Takagi, Ryo; Yamamoto, Mariko; Umemura, Shin-Ichiro
2016-01-01
A noninvasive technique to monitor thermal lesion formation is necessary to ensure the accuracy and safety of high-intensity focused ultrasound (HIFU) treatment. The purpose of this study is to ultrasonically detect the tissue change due to thermal coagulation in the HIFU treatment enhanced by cavitation microbubbles. An ultrasound imaging probe transmitted plane waves at a center frequency of 4.5 MHz. Ultrasonic radio-frequency (RF) echo signals during HIFU exposure at a frequency of 1.2 MHz were acquired. Cross-correlation coefficients were calculated between in-phase and quadrature (IQ) data of two B-mode images with an interval time of 50 and 500 ms for the estimation of the region of cavitation and coagulation, respectively. Pathological examination of the coagulated tissue was also performed to compare with the corresponding ultrasonically detected coagulation region. The distribution of minimum hold cross-correlation coefficient between two sets of IQ data with 50-ms intervals was compared with a pulse inversion (PI) image. The regions with low cross-correlation coefficients approximately corresponded to those with high brightness in the PI image. The regions with low cross-correlation coefficients in 500-ms intervals showed a good agreement with those with significant change in histology. The results show that the regions of coagulation and cavitation could be ultrasonically detected as those with low cross-correlation coefficients between RF frames with certain intervals. This method will contribute to improve the safety and accuracy of the HIFU treatment enhanced by cavitation microbubbles.
High-average-power 2-kHz laser for generation of ultrashort x-ray pulses.
Jiang, Yan; Lee, Taewoo; Li, Wei; Ketwaroo, Gyanprakash; Rose-Petruck, Christoph G
2002-06-01
We describe a Ti:sapphire-based laser-x-ray system specifically designed for generation of ultrafast x-ray pulses in the tenths-of-nanometers spectral range at a 2-kHz repetition rate. To obtain high-contrast laser pulses we divide the laser system into a section for generation of microjoule, high-contrast pulses with pulse cleaning and a subsequent section for chirped-pulse amplification and pulse compression. This laser section operates in conjunction with an x-ray-generation section based on a moving copper wire in a He atmosphere. The high reliability of the entire system permits maintenance-free production of x-ray pulses over tens of hours. Average x-ray fluxes of 10(13) photons/(s 4pi sr 1 keV) at 3 keV and 10(9) photons/(s 4pi sr) above 5 keV of photon energy are produced.
Temporal analysis of the spontaneous baroreceptor reflex during mild emotional stress in the rat.
Bajić, Dragana; Loncar-Turukalo, Tatjana; Stojicić, Sonja; Sarenac, Olivera; Bojić, Tijana; Murphy, David; Paton, Julian F R; Japundzić-Zigon, Nina
2010-03-01
The effect of emotional stress on the spontaneous baroreceptor reflex (sBRR) in freely moving rats was investigated. Six male Wistar rats equipped with an intra-arterial polyethylene catheter were exposed to a 2-min air-jet stress. For time course analysis of the sBRR response to stress, the records of systolic blood pressure (SBP) and pulse interval (PI) were divided into five regions: baseline (BASELINE), acute exposure to air-jet stress (STRESS), immediate recovery (IMMED. RECOVERY), remaining recovery (RECOVERY), and delayed response (DELAYED RESPONSE). In addition to sBRR sensitivity and effectiveness, we introduce the sequence coverage area and its median for evaluation of the sBRR operating range and set point. During exposure to STRESS and IMMED. RECOVERY, sBRR sensitivity was preserved, its effectiveness was decreased, its operating range was enlarged, and the set point was shifted towards higher SBP and lower PI values. According to the joint symbolic dynamics analysis, the SBP and PI relationship became less predictable hence more prone to respond to stress. In RECOVERY the parameters regained baseline values and DELAYED RESPONSE occurred during which re-setting of sBRR was noted. It follows that emotional stress modulates sBRR differentially during the time course of stress and recovery, affecting both linearity and unpredictability of the BP and PI relationship.
Cardiovascular response to acute stress in freely moving rats: time-frequency analysis.
Loncar-Turukalo, Tatjana; Bajic, Dragana; Japundzic-Zigon, Nina
2008-01-01
Spectral analysis of cardiovascular series is an important tool for assessing the features of the autonomic control of the cardiovascular system. In this experiment Wistar rats ecquiped with intraarterial catheter for blood pressure (BP) recording were exposed to stress induced by blowing air. The problem of non stationary data was overcomed applying the Smoothed Pseudo Wigner Villle (SPWV) time-frequency distribution. Spectral analysis was done before stress, during stress, immediately after stress and later in recovery. The spectral indices were calculated for both systolic blood pressure (SBP) and pulse interval (PI) series. The time evolution of spectral indices showed perturbed sympathovagal balance.
Becker, Anton S; Cornelius, Alexander; Reiner, Cäcilia S; Stocker, Daniel; Ulbrich, Erika J; Barth, Borna K; Mortezavi, Ashkan; Eberli, Daniel; Donati, Olivio F
2017-09-01
to simultaneously evaluate interreader agreement and diagnostic accuracy in the of PI-RADS v2 and compare it to v1. A total of 67 patients (median age 65.3 y, range 51.2-78.2 y; PSA 6.8μg/L, 0.2-33μg/L) undergoing MRI of the prostate and subsequent transperineal template biopsy within ≤6 months from MRI were included. Four readers from two institutions evaluated the likelihood of prostate cancer using PI-RADS v1 and v2 in two separate reading sessions ≥3 months apart. Interreader agreement was assessed for each pulse-sequence and for total PI-RADS scores using the intraclass correlation coefficient (ICC). Differences were considered significant for non-overlapping 95%-confidence intervals. Diagnostic accuracy was assessed with the area under the receiver operating characteristic curve (A Z ). A p-value <0.05 was considered statistically significant. Interreader agreement for DCE-scores was good in v2 (ICC 2 =0.70; 95% CI: 0.66-0.74) and slightly lower in v1 (ICC 1 =0.64, 0.59-0.69). Agreement for DWI scores (ICC 1 =0.77, ICC 2 =0.76) as well as final PI-RADS scores per quadrant were nearly identical (ICC 1 =ICC 2 =0.71). Diagnostic accuracy showed no significant differences (p=0.09-0.93) between v1 and v2 in any of the readers (range: A Z =0.78-0.88). PI-RADS scores show similar interreader agreement in v2 and v1 at comparable diagnostic performance. The simplification of the DCE interpretation in v2 might slightly improve agreement while not negatively affecting diagnostic performance. Copyright © 2017 Elsevier B.V. All rights reserved.
Acid proliferation to improve the sensitivity of EUV resists: a pulse radiolysis study
NASA Astrophysics Data System (ADS)
Enomoto, Kazuyuki; Arimitsu, Koji; Yoshizawa, Atsutaro; Yamamoto, Hiroki; Oshima, Akihiro; Kozawa, Takahiro; Tagawa, Seiichi
2011-04-01
The yields of acid have been measured in the electron-beam irradiation of triphenylsulfonium triflate (TPS-Tf) and pinanediol monosulfonates, which consist of tosylate (PiTs), 4-fluorobenzenesulfonate (Pi1F), or 4-trifluoromethylbenzenesulfonate (Pi3F), as an acid amplifier blended in 4-hydroxystyrene matrixes. The acid yields efficiency decreases when PiTs is present, while its efficiency increases in the presence of Pi3F. Reactions of the electrons with TPS-Tf and pinanediol monosulfonates have been studied using pulse radiolysis in liquid tetrahydrofuran (THF) to evaluate the kinetic contributions to acid production. The THF-solvated electrons react with PiTs, Pi1F, and Pi3F to produce the corresponding radical anions; the rate constants are estimated to be 4.1, 5.1, and 9.2 × 1010 M-1 s-1, respectively. Electron transfer from PiTs•-, Pi1F•-, and Pi3F•- radical anions to TPS-Tf occurs with the rate constants of 5.7×1010, 1.2×1011, and 6.3 × 1010 M-1 s-1, respectively. The long-lived Pi3F•- efficiently undergoes the electron transfer to TPS-Tf to form the TPS-Tf•-, which subsequently decompose to generate TfOH. On the other hand, the decay channels of PiTs•- and Pi1F•-, which possess a relatively short lifetime, are presumably dependent on its reactions with solvated protons (charge recombination) rather than the electron transfer to TPS-Tf. The novel acid production pathway via the electron transfer from pinanediol monosulfonate radical anions to TPS-Tf is presented.
Huang, Ho-Shiang; Chu, Chun-Lin; Tsai, Chia-Ti; Wu, Cho-Kai; Lai, Ling-Ping; Yeh, Huei-Ming
2014-01-01
The objective of this study was to test the effect of removal of a ureteral obstruction (renal calculus) from anesthetized patients on the perfusion index (PI), as measured by a pulse oximeter, and on the estimated glomerular filtration rate (eGFR). This prospective study enrolled 113 patients with unilateral ureteral obstructions (kidney stones) who were scheduled for ureteroscopy (URS) laser lithotripsy. One urologist graded patient hydronephrosis before surgery. A pulse oximeter was affixed to each patient's index finger ipsilateral to the intravenous catheter, and a non-invasive blood pressure cuff was placed on the contralateral side. Ipsilateral double J stents and Foley catheters were inserted and left indwelling for 24 h. PI and mean arterial pressure (MAP) were determined at baseline, 5 min after anesthesia, and 10 min after surgery; eGFR was determined at admission, 1 day after surgery, and 14 days after surgery. Patients with different grades of hydronephrosis had similar age, eGFR, PI, mean arterial pressure (MAP), and heart rate (HR). PI increased significantly in each hydronephrosis group after ureteral stone disintegration. None of the groups had significant post-URS changes in eGFR, although eGFR increased in the grade I hydronephrosis group after 14 days. The percent change of PI correlates significantly with the percent change of MAP, but not with that of eGFR. Our results demonstrate that release of a ureteral obstruction leads to a concurrent increase of PI during anesthesia. Measurement of PI may be a valuable tool to monitor the successful release of ureteral obstructions and changes of microcirculation during surgery. There were also increases in eGFR after 14 days, but not immediately after surgery.
Huang, Ho-Shiang; Chu, Chun-Lin; Tsai, Chia-Ti; Wu, Cho-Kai; Lai, Ling-Ping; Yeh, Huei-Ming
2014-01-01
Background The objective of this study was to test the effect of removal of a ureteral obstruction (renal calculus) from anesthetized patients on the perfusion index (PI), as measured by a pulse oximeter, and on the estimated glomerular filtration rate (eGFR). Patients and Methods This prospective study enrolled 113 patients with unilateral ureteral obstructions (kidney stones) who were scheduled for ureteroscopy (URS) laser lithotripsy. One urologist graded patient hydronephrosis before surgery. A pulse oximeter was affixed to each patient's index finger ipsilateral to the intravenous catheter, and a non-invasive blood pressure cuff was placed on the contralateral side. Ipsilateral double J stents and Foley catheters were inserted and left indwelling for 24 h. PI and mean arterial pressure (MAP) were determined at baseline, 5 min after anesthesia, and 10 min after surgery; eGFR was determined at admission, 1 day after surgery, and 14 days after surgery. Results Patients with different grades of hydronephrosis had similar age, eGFR, PI, mean arterial pressure (MAP), and heart rate (HR). PI increased significantly in each hydronephrosis group after ureteral stone disintegration. None of the groups had significant post-URS changes in eGFR, although eGFR increased in the grade I hydronephrosis group after 14 days. The percent change of PI correlates significantly with the percent change of MAP, but not with that of eGFR. Conclusion Our results demonstrate that release of a ureteral obstruction leads to a concurrent increase of PI during anesthesia. Measurement of PI may be a valuable tool to monitor the successful release of ureteral obstructions and changes of microcirculation during surgery. There were also increases in eGFR after 14 days, but not immediately after surgery. PMID:25542000
Controlling coherence using the internal structure of hard pi pulses.
Dong, Yanqun; Ramos, R G; Li, Dale; Barrett, S E
2008-06-20
The tiny difference between hard pi pulses and their delta-function approximation can be exploited to control coherence. Variants on the magic echo that work despite a large spread in resonance offsets are demonstrated using the zeroth- and first-order average Hamiltonian terms, for 13C NMR in 60C. The 29Si NMR linewidth of silicon has been reduced by a factor of about 70,00 using this approach, which also has potential applications in magnetic resonance microscopy and imaging of solids.
Kariman, Khalil; Barker, Susan J; Jost, Ricarda; Finnegan, Patrick M; Tibbett, Mark
2016-07-01
Many plant species adapted to P-impoverished soils, including jarrah (Eucalyptus marginata), develop toxicity symptoms when exposed to high doses of phosphate (Pi) and its analogs such as phosphite (Phi) and arsenate (AsV). The present study was undertaken to investigate the effects of fungal symbionts Scutellospora calospora, Scleroderma sp., and Austroboletus occidentalis on the response of jarrah to highly toxic pulses (1.5 mmol kg(-1) soil) of Pi, Phi, and AsV. S. calospora formed an arbuscular mycorrhizal (AM) symbiosis while both Scleroderma sp. and A. occidentalis established a non-colonizing symbiosis with jarrah plants. All these interactions significantly improved jarrah growth and Pi uptake under P-limiting conditions. The AM fungal colonization naturally declines in AM-eucalypt symbioses after 2-3 months; however, in the present study, the high Pi pulse inhibited the decline of AM fungal colonization in jarrah. Four weeks after exposure to the Pi pulse, plants inoculated with S. calospora had significantly lower toxicity symptoms compared to non-mycorrhizal (NM) plants, and all fungal treatments induced tolerance against Phi toxicity in jarrah. However, no tolerance was observed for AsV-treated plants even though all inoculated plants had significantly lower shoot As concentrations than the NM plants. The transcript profile of five jarrah high-affinity phosphate transporter (PHT1 family) genes in roots was not altered in response to any of the fungal species tested. Interestingly, plants exposed to high Pi supplies for 1 day did not have reduced transcript levels for any of the five PHT1 genes in roots, and transcript abundance of four PHT1 genes actually increased. It is therefore suggested that jarrah, and perhaps other P-sensitive perennial species, respond positively to Pi available in the soil solution through increasing rather than decreasing the expression of selected PHT1 genes. Furthermore, Scleroderma sp. can be considered as a fungus with dual functional capacity capable of forming both ectomycorrhizal and non-colonizing associations, where both pathways are always accompanied by evident growth and nutritional benefits.
Toyama, S; Kakumoto, M; Morioka, M; Matsuoka, K; Omatsu, H; Tagaito, Y; Numai, T; Shimoyama, M
2013-08-01
Hypotension during spinal anaesthesia for Caesarean delivery is a result of decreased vascular resistance due to sympathetic blockade and decreased cardiac output due to blood pooling in blocked areas of the body. Change in baseline peripheral vascular tone due to pregnancy may affect the degree of such hypotension. The perfusion index (PI) derived from a pulse oximeter has been used for assessing peripheral perfusion dynamics due to changes in peripheral vascular tone. The aim of this study was to examine whether baseline PI could predict the incidence of spinal anaesthesia-induced hypotension during Caesarean delivery. Parturients undergoing elective Caesarean delivery under spinal anaesthesia with hyperbaric bupivacaine 10 mg and fentanyl 20 μg were enrolled in this prospective study. The correlation between baseline PI and the degree of hypotension during spinal anaesthesia and also the predictability of spinal anaesthesia-induced hypotension during Caesarean delivery by PI were investigated. Baseline PI correlated with the degree of decreases in systolic and mean arterial pressure (r=0.664, P<0.0001 and r=0.491, P=0.0029, respectively). The cut-off PI value of 3.5 identified parturients at risk for spinal anaesthesia-induced hypotension with a sensitivity of 81% and a specificity of 86% (P<0.001). The change of PI in parturients with baseline PI ≤ 3.5 was not significant during the observational period, while PI in parturients with baseline PI>3.5 demonstrated marked decreases after spinal injection. We demonstrated that higher baseline PI was associated with profound hypotension and that baseline PI could predict the incidence of spinal anaesthesia-induced hypotension during Caesarean delivery.
Al-Jameil, Noura; Hassan, Amina A; Hassanato, Rana; Isac, Sree R; Otaiby, Maram Al; Al-Shareef, Fadwa; Al-Maarik, Basmah; Ajeyan, Iman Al; Al-Bahloul, Khloud; Ghani, Samina; Al-Torbak, Dana
2017-10-01
Alpha-1 antitrypsin (AAT) is an acute phase protein produced in hepatocytes. Its deficiency affects the lungs and liver. A case-control study was carried out to determine the prevalence of 2 common deficiency alleles, PI*S and PI*Z, for alpha-1 antitrypsin deficiency (AATD) in both healthy and chronic obstructive pulmmonary disease (COPD)-affected Saudi populations and to clarify the importance of genetic tests in the screening of people at risk for COPD.One thousand blood samples from healthy individuals and 1000 from COPD-affected Saudi individuals were genotyped for the above-mentioned alleles, using real-time polymerase chain reaction (PCR), with the exclusion of any other nationalities. Data were analyzed by determining the allele and genotype frequencies through gene counting and its confidence intervals. The allele frequencies, derived by the Hardy-Weinberg equilibrium method, were analyzed by Pearson Chi-squared tests. The confidence intervals for genotype frequencies were calculated using exploratory software for confidence intervals.Of the 1000 COPD patients included in our study, the prevalence of PI*S and PI*Z was 21.8% and 7.7%, respectively, while within the 1000 normal samples, these alleles occurred in 8.9% of patients for PI*S and 1.6% for PI*Z. The AAT deficiency genotype frequencies (PI*ZZ, PI*SS, and PI*SZ) were 6.5 per 1000 and 87 per 1000 for normal and COPD-affected Saudi individuals.Our results indicated a high prevalence of AATD alleles in the normal Saudi population and an association between AAT deficiency and pulmonary disease development. Additionally, our research confirms the importance of genetic screening to achieve early and accurate diagnosis of AATD.
Membrane permeabilization of mammalian cells using bursts of high magnetic field pulses
Grainys, Audrius; Kranjc, Matej; Miklavčič, Damijan
2017-01-01
Background Cell membrane permeabilization by pulsed electromagnetic fields (PEMF) is a novel contactless method which results in effects similar to conventional electroporation. The non-invasiveness of the methodology, independence from the biological object homogeneity and electrical conductance introduce high flexibility and potential applicability of the PEMF in biomedicine, food processing, and biotechnology. The inferior effectiveness of the PEMF permeabilization compared to standard electroporation and the lack of clear description of the induced transmembrane transport are currently of major concern. Methods The PEMF permeabilization experiments have been performed using a 5.5 T, 1.2 J pulse generator with a multilayer inductor as an applicator. We investigated the feasibility to increase membrane permeability of Chinese Hamster Ovary (CHO) cells using short microsecond (15 µs) pulse bursts (100 or 200 pulses) at low frequency (1 Hz) and high dB/dt (>106 T/s). The effectiveness of the treatment was evaluated by fluorescence microscopy and flow cytometry using two different fluorescent dyes: propidium iodide (PI) and YO-PRO®-1 (YP). The results were compared to conventional electroporation (single pulse, 1.2 kV/cm, 100 µs), i.e., positive control. Results The proposed PEMF protocols (both for 100 and 200 pulses) resulted in increased number of permeable cells (70 ± 11% for PI and 67 ± 9% for YP). Both cell permeabilization assays also showed a significant (8 ± 2% for PI and 35 ± 14% for YP) increase in fluorescence intensity indicating membrane permeabilization. The survival was not affected. Discussion The obtained results demonstrate the potential of PEMF as a contactless treatment for achieving reversible permeabilization of biological cells. Similar to electroporation, the PEMF permeabilization efficacy is influenced by pulse parameters in a dose-dependent manner. PMID:28462057
Cho, Han-Jin; Lee, Kyung Yul; Nam, Hyo Suk; Kim, Young Dae; Song, Tae-Jin; Jung, Yo Han; Choi, Hye-Yeon; Heo, Ji Hoe
2014-10-01
Process improvement (PI) is an approach for enhancing the existing quality improvement process by making changes while keeping the existing process. We have shown that implementation of a stroke code program using a computerized physician order entry system is effective in reducing the in-hospital time delay to thrombolysis in acute stroke patients. We investigated whether implementation of this PI could further reduce the time delays by continuous improvement of the existing process. After determining a key indicator [time interval from emergency department (ED) arrival to intravenous (IV) thrombolysis] and conducting data analysis, the target time from ED arrival to IV thrombolysis in acute stroke patients was set at 40 min. The key indicator was monitored continuously at a weekly stroke conference. The possible reasons for the delay were determined in cases for which IV thrombolysis was not administered within the target time and, where possible, the problems were corrected. The time intervals from ED arrival to the various evaluation steps and treatment before and after implementation of the PI were compared. The median time interval from ED arrival to IV thrombolysis in acute stroke patients was significantly reduced after implementation of the PI (from 63.5 to 45 min, p=0.001). The variation in the time interval was also reduced. A reduction in the evaluation time intervals was achieved after the PI [from 23 to 17 min for computed tomography scanning (p=0.003) and from 35 to 29 min for complete blood counts (p=0.006)]. PI is effective for continuous improvement of the existing process by reducing the time delays between ED arrival and IV thrombolysis in acute stroke patients.
Pulsed Electromagnetic Field Assisted in vitro Electroporation: A Pilot Study
NASA Astrophysics Data System (ADS)
Novickij, Vitalij; Grainys, Audrius; Lastauskienė, Eglė; Kananavičiūtė, Rūta; Pamedytytė, Dovilė; Kalėdienė, Lilija; Novickij, Jurij; Miklavčič, Damijan
2016-09-01
Electroporation is a phenomenon occurring due to exposure of cells to Pulsed Electric Fields (PEF) which leads to increase of membrane permeability. Electroporation is used in medicine, biotechnology, and food processing. Recently, as an alternative to electroporation by PEF, Pulsed ElectroMagnetic Fields (PEMF) application causing similar biological effects was suggested. Since induced electric field in PEMF however is 2-3 magnitudes lower than in PEF electroporation, the membrane permeabilization mechanism remains hypothetical. We have designed pilot experiments where Saccharomyces cerevisiae and Candida lusitaniae cells were subjected to single 100-250 μs electrical pulse of 800 V with and without concomitant delivery of magnetic pulse (3, 6 and 9 T). As expected, after the PEF pulses only the number of Propidium Iodide (PI) fluorescent cells has increased, indicative of membrane permeabilization. We further show that single sub-millisecond magnetic field pulse did not cause detectable poration of yeast. Concomitant exposure of cells to pulsed electric (PEF) and magnetic field (PMF) however resulted in the increased number PI fluorescent cells and reduced viability. Our results show increased membrane permeability by PEF when combined with magnetic field pulse, which can explain electroporation at considerably lower electric field strengths induced by PEMF compared to classical electroporation.
Pulsed Electromagnetic Field Assisted in vitro Electroporation: A Pilot Study
Novickij, Vitalij; Grainys, Audrius; Lastauskienė, Eglė; Kananavičiūtė, Rūta; Pamedytytė, Dovilė; Kalėdienė, Lilija; Novickij, Jurij; Miklavčič, Damijan
2016-01-01
Electroporation is a phenomenon occurring due to exposure of cells to Pulsed Electric Fields (PEF) which leads to increase of membrane permeability. Electroporation is used in medicine, biotechnology, and food processing. Recently, as an alternative to electroporation by PEF, Pulsed ElectroMagnetic Fields (PEMF) application causing similar biological effects was suggested. Since induced electric field in PEMF however is 2–3 magnitudes lower than in PEF electroporation, the membrane permeabilization mechanism remains hypothetical. We have designed pilot experiments where Saccharomyces cerevisiae and Candida lusitaniae cells were subjected to single 100–250 μs electrical pulse of 800 V with and without concomitant delivery of magnetic pulse (3, 6 and 9 T). As expected, after the PEF pulses only the number of Propidium Iodide (PI) fluorescent cells has increased, indicative of membrane permeabilization. We further show that single sub-millisecond magnetic field pulse did not cause detectable poration of yeast. Concomitant exposure of cells to pulsed electric (PEF) and magnetic field (PMF) however resulted in the increased number PI fluorescent cells and reduced viability. Our results show increased membrane permeability by PEF when combined with magnetic field pulse, which can explain electroporation at considerably lower electric field strengths induced by PEMF compared to classical electroporation. PMID:27634482
Design and Testing of a Small Inductive Pulsed Plasma Thruster
NASA Technical Reports Server (NTRS)
Martin, Adam K.; Eskridge, Richard H.; Dominguez, Alexandra; Polzin, Kurt A.; Riley, Daniel P.; Kimberlin, Adam C.
2015-01-01
The design and testing of a small inductive pulsed plasma thruster (IPPT), shown in Fig. 1 with all the major subsystems required for a thruster of this kind are described. Thrust measurements and imaging of the device operated in rep-rated mode are presented to quantify the performance envelope of the device. The small IPPT described in this paper was designed to serve as a test-bed for the pulsed gas-valves and solid-state switches required for a IPPTs. A modular design approach was used to permit future modifications and upgrades. The thruster consists of the following sub-systems: a) a multi-turn, spiral-wound acceleration coil (27 cm o.d., 10 cm i.d.) driven by a 10 microFarad capacitor and switched with a high-voltage thyristor, b) a fast pulsed gas-valve, and c.) a glow-discharge pre-ionizer (PI) circuit. The acceleration-coil circuit may be operated at voltages up to 4 kV (the thyristor limit is 4.5 kV). The device may be operated at rep-rates up to 30 Hz with the present gas-valve. Thrust measurements and imaging of the device operated in rep-rated mode will be presented. The pre-ionizer consists of a 0.3 microFarad capacitor charged to 4 kV and connected to two annular stainless-steel electrodes bounding the area of the coil-face. The 4 kV potential is held across them and when the gas is puffed in over the coil, the PI circuit is completed, and a plasma is formed. Even at the less than optimal base-pressure in the chamber (approximately 5 × 10(exp -4) torr), the PI held-off the applied voltage, and only discharged upon command. For a capacitor charge of 2 kV the peak coil current is 4.1 kA, and during this pulse a very bright discharge (much brighter than from the PI alone) was observed (see Fig. 2). Interestingly, for discharges at this charge voltage the PI was not required as the current rise rate, dI/dt, of the coil itself was sufficient to ionize the gas.
TIME-INTERVAL MEASURING DEVICE
Gross, J.E.
1958-04-15
An electronic device for measuring the time interval between two control pulses is presented. The device incorporates part of a previous approach for time measurement, in that pulses from a constant-frequency oscillator are counted during the interval between the control pulses. To reduce the possible error in counting caused by the operation of the counter gating circuit at various points in the pulse cycle, the described device provides means for successively delaying the pulses for a fraction of the pulse period so that a final delay of one period is obtained and means for counting the pulses before and after each stage of delay during the time interval whereby a plurality of totals is obtained which may be averaged and multplied by the pulse period to obtain an accurate time- Interval measurement.
Evaluation of Masimo signal extraction technology pulse oximetry in anaesthetized pregnant sheep.
Quinn, Christopher T; Raisis, Anthea L; Musk, Gabrielle C
2013-03-01
Evaluation of the accuracy of Masimo signal extraction technology (SET) pulse oximetry in anaesthetized late gestational pregnant sheep. Prospective experimental study. Seventeen pregnant Merino ewes. Animals included in study were late gestation ewes undergoing general anaesthesia for Caesarean delivery or foetal surgery in a medical research laboratory. Masimo Radical-7 pulse oximetry (SpO(2) ) measurements were compared to co-oximetry (SaO(2) ) measurements from arterial blood gas analyses. The failure rate of the pulse oximeter was calculated. Accuracy was assessed by Bland & Altman's (2007) limits of agreement method. The effect of mean arterial blood pressure (MAP), perfusion index (PI) and haemoglobin (Hb) concentration on accuracy were assessed by regression analysis. Forty arterial blood samples paired with SpO(2) and blood pressure measurements were obtained. SpO(2) ranged from 42 to 99% and SaO(2) from 43.7 to 99.9%. MAP ranged from 24 to 82 mmHg, PI from 0.1 to 1.56 and Hb concentration from 71 to 114 g L(-1) . Masimo pulse oximetry measurements tended to underestimate oxyhaemoglobin saturation compared to co-oximetry with a bias (mean difference) of -2% and precision (standard deviation of the differences) of 6%. Accuracy appeared to decrease when SpO(2) was <75%, however numbers were too small for statistical comparisons. Hb concentration and PI had no significant effect on accuracy, whereas MAP was negatively correlated with SpO(2) bias. Masimo SET pulse oximetry can provide reliable and continuous monitoring of arterial oxyhaemoglobin saturation in anaesthetized pregnant sheep during clinically relevant levels of cardiopulmonary dysfunction. Further work is needed to assess pulse oximeter function during extreme hypotension and hypoxaemia. © 2012 The Authors. Veterinary Anaesthesia and Analgesia. © 2012 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesiologists.
NASA Astrophysics Data System (ADS)
Scher, Howie; Bohaty, Steven; Huck, Claire
2017-04-01
Glaciation of Antarctica was the pièce de résistance of the shift in global climate that took place during the Eocene Oligocene Transition (EOT; ca. 34 Ma). The timing and progression of ice-sheet development is constrained by benthic foraminiferal d18O records and geochemical proxies for continental weathering from deep-sea sediment cores. The terrace interval is the roughly 500 kyr interval after the precursor glaciation at 34.2 Ma, when ice-sheet expansion reached a short-lived plateau prior to the coalescence of a continent-scale ice sheet at 33.7 Ma. The terrace interval appears to be the tipping point between greenhouse and icehouse climate states, however ice-sheet dynamics are poorly understood during this crucial time. We present evidence for rapid changes in the Nd isotopic composition of bottom waters bathing a sediment core on Maud Rise (ODP Site 689) during the terrace interval of the EOT. Three distinct excursions toward less radiogenic eNd values suggest either 1) changes in the flux of Antarctic weathering products into the Weddell Sea and/or 2) pulses of deep water production that brought shelf waters with the Antarctic Nd isotope fingerprint into contact with Maud Rise. Both interpretations support a scenario of expansion and contraction of the Antarctic ice sheet during the terrace interval.
Park, Jinhyoung; Li, Xiang; Zhou, Qifa; Shung, K. Kirk
2013-01-01
The application of chirp coded excitation to pulse inversion tissue harmonic imaging can increase signal to noise ratio. On the other hand, the elevation of range side lobe level, caused by leakages of the fundamental signal, has been problematic in mechanical scanners which are still the most prevalent in high frequency intravascular ultrasound imaging. Fundamental chirp coded excitation imaging can achieve range side lobe levels lower than –60 dB with Hanning window, but it yields higher side lobes level than pulse inversion chirp coded tissue harmonic imaging (PI-CTHI). Therefore, in this paper a combined pulse inversion chirp coded tissue harmonic and fundamental imaging mode (CPI-CTHI) is proposed to retain the advantages of both chirp coded harmonic and fundamental imaging modes by demonstrating 20–60 MHz phantom and ex vivo results. A simulation study shows that the range side lobe level of CPI-CTHI is 16 dB lower than PI-CTHI, assuming that the transducer translates incident positions by 50 μm when two beamlines of pulse inversion pair are acquired. CPI-CTHI is implemented for a proto-typed intravascular ultrasound scanner capable of combined data acquisition in real-time. A wire phantom study shows that CPI-CTHI has a 12 dB lower range side lobe level and a 7 dB higher echo signal to noise ratio than PI-CTHI, while the lateral resolution and side lobe level are 50 μm finer and –3 dB less than fundamental chirp coded excitation imaging respectively. Ex vivo scanning of a rabbit trachea demonstrates that CPI-CTHI is capable of visualizing blood vessels as small as 200 μm in diameter with 6 dB better tissue contrast than either PI-CTHI or fundamental chirp coded excitation imaging. These results clearly indicate that CPI-CTHI may enhance tissue contrast with less range side lobe level than PI-CTHI. PMID:22871273
Martin, A.D.
1986-05-09
Method and apparatus are provided for generating an output pulse following a trigger pulse at a time delay interval preset with a resolution which is high relative to a low resolution available from supplied clock pulses. A first lumped constant delay provides a first output signal at predetermined interpolation intervals corresponding to the desired high resolution time interval. Latching circuits latch the high resolution data to form a first synchronizing data set. A selected time interval has been preset to internal counters and corrected for circuit propagation delay times having the same order of magnitude as the desired high resolution. Internal system clock pulses count down the counters to generate an internal pulse delayed by an internal which is functionally related to the preset time interval. A second LCD corrects the internal signal with the high resolution time delay. A second internal pulse is then applied to a third LCD to generate a second set of synchronizing data which is complementary with the first set of synchronizing data for presentation to logic circuits. The logic circuits further delay the internal output signal with the internal pulses. The final delayed output signal thereafter enables the output pulse generator to produce the desired output pulse at the preset time delay interval following input of the trigger pulse.
High resolution digital delay timer
Martin, Albert D.
1988-01-01
Method and apparatus are provided for generating an output pulse following a trigger pulse at a time delay interval preset with a resolution which is high relative to a low resolution available from supplied clock pulses. A first lumped constant delay (20) provides a first output signal (24) at predetermined interpolation intervals corresponding to the desired high resolution time interval. Latching circuits (26, 28) latch the high resolution data (24) to form a first synchronizing data set (60). A selected time interval has been preset to internal counters (142, 146, 154) and corrected for circuit propagation delay times having the same order of magnitude as the desired high resolution. Internal system clock pulses (32, 34) count down the counters to generate an internal pulse delayed by an interval which is functionally related to the preset time interval. A second LCD (184) corrects the internal signal with the high resolution time delay. A second internal pulse is then applied to a third LCD (74) to generate a second set of synchronizing data (76) which is complementary with the first set of synchronizing data (60) for presentation to logic circuits (64). The logic circuits (64) further delay the internal output signal (72) to obtain a proper phase relationship of an output signal (80) with the internal pulses (32, 34). The final delayed output signal (80) thereafter enables the output pulse generator (82) to produce the desired output pulse (84) at the preset time delay interval following input of the trigger pulse (10, 12).
Takahashi, S; Kakiuchi, S; Nanba, Y; Tsukamoto, K; Nakamura, T; Ito, Y
2010-04-01
Superior vena cava (SVC) flow is used as an index for evaluating systemic blood flow in neonates. Thus far, several reports have shown that low SVC flow is a risk factor for intraventricular hemorrhage (IVH) in the preterm infant. Therefore, it is likely to be a useful index in the management of the preterm infant. The perfusion index (PI) derived from a pulse oximeter is a marker that allows noninvasive and continuous monitoring of peripheral perfusion. The objective of this paper was to determine the accuracy of the PI for detecting low SVC flow in very low birth weight infants born before 32 weeks of gestation. We studied the correlation between PI and SVC flow 0 to 72 h after birth in very low birth weight infants born before 32 weeks of gestation. The best cut-off value for low SVC flow was calculated from the respective receiver-operating characteristic curves. A positive correlation was found between the PI and SVC flow (r=0.509, P<0.001). The best cut-off value for the PI to detect low SVC flow was 0.44 (sensitivity 87.5%, specificity 86.3%, positive predictive value 38.9%, negative predictive value 98.6%). This study found that the PI was associated with SVC flow, and it was a useful index for detecting low SVC flow in very low birth weight infants born before 32 weeks of gestation. Therefore, use of the PI should be evaluated in the cardiovascular management of the preterm infant.
Marjanović, Ivan; Mijajlović, Milija; Covicković-Sternić, Nadezda; Kontić, Djordje; Hentova-Senćanić, Paraskeva; Marković, Vujica; Bozić, Marija
2011-01-01
An altered perfusion of the optic nerve head has been proposed as a pathogenic factor in glaucoma. The aim of this study was to evaluate the correlation between ocular pulse amplitude (OPA), measured by Dynamic contour tonometer (DCT) and colour Doppler imaging (CDI) of the arteric retrobulbar vessels. Twenty patients older than 50 years were examined, and divided into two equal groups. The first group comprised of patients with normal tension glaucoma treated with topical antiglaucomatous therapy, and the second group included patients with ocular hypertension and glaucoma suspicious without any antiglaucomatous therapy. Ocular pulse amplitude (OPA) was measured with DCT. CDI was also performed. We measured haemodynamic parameters of the internal carotid artery (ICA), ophthalmic artery (OA), central retinal artery (CRA), and posterior ciliary arteries (PCA). Peak systolic (PSV), end-diastolic (EDV) velocities were measured, and resistance index (RI) and pulsatility index (PI) were calculated. Correlation with OPA showed indirect servitude in the RI of the ICA, RI and PI of the CRA, in the first group; and in the PSV and EDV of the ICA, in the RI and PI of the OA, EDV and RI of the CRA, and RI of the PCA, in the second group Increase of OPA was mostly followed by the increase of the parameters (PSV, EDV, RI, and PI) of the arteric retrobulbar vessels in the first group; in the second group, increase of OPA was in almost 50% of parameters followed by their decrease.
Ren, Jimin; Sherry, A Dean; Malloy, Craig R
2015-12-01
The goal of this study was to amplify the effects of magnetization exchange between γ-adenosine triphosphate (ATP) and inorganic phosphate (Pi) for evaluation of ATP synthesis rates in human skeletal muscle. The strategy works by simultaneously inverting the (31) P resonances of phosphocreatine (PCr) and ATP using a wide bandwidth, adiabatic inversion radiofrequency pulse followed by observing dynamic changes in intensity of the noninverted Pi signal versus the delay time between the inversion and observation pulses. This band inversion technique significantly delays recovery of γ-ATP magnetization; consequently, the exchange reaction, Pi ↔ γ-ATP, is readily detected and easily analyzed. The ATP synthesis rate measured from high-quality spectral data using this method was 0.073 ± 0.011 s(-1) in resting human skeletal muscle (N = 10). The T1 of Pi was 6.93 ± 1.90 s, consistent with the intrinsic T1 of Pi at this field. The apparent T1 of γ-ATP was 4.07 ± 0.32 s, about two-fold longer than its intrinsic T1 due to storage of magnetization in PCr. Band inversion provides an effective method to amplify the effects of magnetization transfer between γ-ATP and Pi. The resulting data can be easily analyzed to obtain the ATP synthesis rate using a two-site exchange model. © 2014 Wiley Periodicals, Inc.
Relationship between perfusion index and patent ductus arteriosus in preterm infants.
Gomez-Pomar, Enrique; Makhoul, Majd; Westgate, Philip M; Ibonia, Katrina T; Patwardhan, Abhijit; Giannone, Peter J; Bada, Henrietta S; Abu Jawdeh, Elie G
2017-05-01
Perfusion index (PI) is a noninvasive measure of perfusion. ΔPI (difference between pre- and postductal PI) may identify hemodynamically significant PDA. However, studies are limited to brief and intermittent ΔPI sampling. Our objective is to assess the value of continuous high resolution ΔPI monitoring in the diagnosis of PDA. Continuous ΔPI monitoring in preterm infants was prospectively performed using two high-resolution pulse oximeters. Perfusion Index measures (ΔPI mean and variability, pre- and postductal PI) were analyzed over a 4-h period prior to echocardiography. A cardiologist blinded to the results evaluated for PDA on echocardiography. Linear mixed regression models were utilized for analyses. We obtained 31 echocardiography observations. Mean ΔPI (-0.23 vs. 0.16; P < 0.05), mean pre-PI (0.86 vs. 1.26; P < 0.05), and ΔPI variability (0.39 vs. 0.61; P = 0.05) were lower in infants with PDA compared to infants without PDA at the time of echocardiography. Mean ΔPI, ΔPI variability, and mean pre-PI measured 4 h prior to echocardiography detect PDA in preterm infants. PI is dynamic and should be assessed continuously. Perfusion index is a promising bedside measurement to identify PDA in preterm infants.
Spectroscopic study of bipolar nanosecond pulse gas-liquid discharge in atmospheric argon
NASA Astrophysics Data System (ADS)
Sen, WANG; Dezheng, YANG; Feng, LIU; Wenchun, WANG; Zhi, FANG
2018-07-01
Atmospheric gas-liquid discharge with argon as a working gas is presented by employed nanosecond pulse power. The discharge is presented in a glow-like mode. The discharge powers are determined to be less than 1 W, and remains almost constant when the discharge duration time increases. Bountiful active species are determined by capturing optical emission spectra, and their main generation processes are also discussed. The plasma gas temperature is calculated as 350 K by comparing the experimental spectra and the simulated ones of {{{N}}}2({{C}}{}3{{\\Pi }}{{g}}\\to {{B}}{}3{{\\Pi }}{{g}},{{Δ }}{{ν }}=-2). The time resolved vibrational and rotational temperature is researched to present the stability of discharge when pulse voltage and discharge duration vary. The electron density is determined to be 1016 cm‑3 according to the Stark broadening effect of the H α line.
Surface microstructure and chemistry of polyimide by single pulse ablation of picosecond laser
NASA Astrophysics Data System (ADS)
Du, Qifeng; Chen, Ting; Liu, Jianguo; Zeng, Xiaoyan
2018-03-01
Polyimide (PI) surface was ablated by the single pulse of picosecond laser, and the effects of laser wavelength (λ= 355 nm and 1064 nm) and fluence on surface microstructure and chemistry were explored. Scanning electron microscopy (SEM) analysis found that different surface microstructures, i.e., the concave of concentric ring and the convex of porous circular disk, were generated by 355 nm and 1064 nm picosecond laser ablation, respectively. X-ray photoelectron spectroscopy (XPS) characterization indicated that due to the high peak energy density of picosecond laser, oxygen and nitrogen from the ambient were incorporated into the PI surface mainly in the form of Cdbnd O and Csbnd Nsbnd C groups. Thus, both of the O/C and N/C atomic content ratios increased, but the increase caused by 1064 nm wavelength laser was larger. It inferred that the differences of PI surface microstructures and chemistry resulted from different laser parameters were related to different laser-matter interaction effects. For 355 nm picosecond laser, no obvious thermal features were observed and the probable ablation process of PI was mainly governed by photochemical effect; while for 1064 nm picosecond laser, obvious thermal feature appeared and photothermal effect was thought to be dominant.
Xu, Zifeng; Zhang, Jianhai; Shen, Hao; Zheng, Jijian
2013-01-01
Whether pulse oximeter perfusion index (PI) may be applied to detect the onset of caudal block in pediatric patients under ketamine intravenous basal anesthesia is investigated. 40 ASA I, 2-8-year-old boys scheduled for elective circumcision surgery were randomized into two groups. Group I: 20 patients were anesthetized by 2 mg·kg(-1) ketamine intravenous injection (IV) followed by caudal block using 1 mL·kg(-1) lidocaine (1%); Group II: 20 patients were anesthetized by 2 mg·kg(-1) ketamine IV only. PI on the toe in Group II decreased by 33 ± 12%, 71 ± 9% and 65 ± 8% at 1 min, 15 min, and 30 min after ketamine injection. The maximum increase in MAP and HR after ketamine IV was 11 ± 6% at 3 min and 10 ± 6% at 2 min. Compared to the PI value before caudal injection of lidocaine, PI in Group I increased by 363 ± 318% and 778 ± 578% at 5 min and 20 min after caudal block, while no significant changes in MAP and HR were found compared to the baseline before caudal block. Thus, PI provides an earlier, more objective, and more sensitive indicator to assess the early onset of caudal block under basal ketamine anesthesia.
High resolution data acquisition
Thornton, G.W.; Fuller, K.R.
1993-04-06
A high resolution event interval timing system measures short time intervals such as occur in high energy physics or laser ranging. Timing is provided from a clock, pulse train, and analog circuitry for generating a triangular wave synchronously with the pulse train (as seen in diagram on patent). The triangular wave has an amplitude and slope functionally related to the time elapsed during each clock pulse in the train. A converter forms a first digital value of the amplitude and slope of the triangle wave at the start of the event interval and a second digital value of the amplitude and slope of the triangle wave at the end of the event interval. A counter counts the clock pulse train during the interval to form a gross event interval time. A computer then combines the gross event interval time and the first and second digital values to output a high resolution value for the event interval.
High resolution data acquisition
Thornton, Glenn W.; Fuller, Kenneth R.
1993-01-01
A high resolution event interval timing system measures short time intervals such as occur in high energy physics or laser ranging. Timing is provided from a clock (38) pulse train (37) and analog circuitry (44) for generating a triangular wave (46) synchronously with the pulse train (37). The triangular wave (46) has an amplitude and slope functionally related to the time elapsed during each clock pulse in the train. A converter (18, 32) forms a first digital value of the amplitude and slope of the triangle wave at the start of the event interval and a second digital value of the amplitude and slope of the triangle wave at the end of the event interval. A counter (26) counts the clock pulse train (37) during the interval to form a gross event interval time. A computer (52) then combines the gross event interval time and the first and second digital values to output a high resolution value for the event interval.
Dual-pulse laser ignition of ethylene-air mixtures in a supersonic combustor.
Yang, Leichao; An, Bin; Liang, Jianhan; Li, Xipeng; Wang, Zhenguo
2018-04-02
To reduce the energy of an individual laser pulse, dual-pulse laser ignitions (LIs) at various pulse intervals were investigated in a Mach 2.92 scramjet engine fueled with ethylene. For comparison, experiments on a single-pulse LI were also performed. Schlieren visualization and high-speed photography were employed to observe the ignition processes simultaneously. The results indicate that the energy of an individual laser pulse can be reduced by half via a dual-pulse LI method as compared with a single-pulse LI with the same total energy. The reduction of the individual laser pulse energy degrades the requirements on the laser source and the beam delivery system, which facilitates the practical application of LI in hypersonic vehicles. A pulse interval shorter than 40 μs is suggested for dual-pulse LI in the present study. Because of the intense heat loss and radical dissipation in high-speed flows, the pulse interval for dual-pulse LI should be short enough to narrow the spatial distribution of the initial flame kernel.
Sunspot Time Series: Passive and Active Intervals
NASA Astrophysics Data System (ADS)
Zięba, S.; Nieckarz, Z.
2014-07-01
Solar activity slowly and irregularly decreases from the first spotless day (FSD) in the declining phase of the old sunspot cycle and systematically, but also in an irregular way, increases to the new cycle maximum after the last spotless day (LSD). The time interval between the first and the last spotless day can be called the passive interval (PI), while the time interval from the last spotless day to the first one after the new cycle maximum is the related active interval (AI). Minima of solar cycles are inside PIs, while maxima are inside AIs. In this article, we study the properties of passive and active intervals to determine the relation between them. We have found that some properties of PIs, and related AIs, differ significantly between two group of solar cycles; this has allowed us to classify Cycles 8 - 15 as passive cycles, and Cycles 17 - 23 as active ones. We conclude that the solar activity in the PI declining phase (a descending phase of the previous cycle) determines the strength of the approaching maximum in the case of active cycles, while the activity of the PI rising phase (a phase of the ongoing cycle early growth) determines the strength of passive cycles. This can have implications for solar dynamo models. Our approach indicates the important role of solar activity during the declining and the rising phases of the solar-cycle minimum.
Páramo, Alejandra; Canosa, André; Le Picard, Sébastien D; Sims, Ian R
2006-03-09
A low-temperature gas-phase kinetics study of the reactions and collisional relaxation processes involving C2(X1Sigma(g)+) and C2(a3Pi(u)) in collision with O2 and NO partners at temperatures from 300 to 24 K is reported. The experiments employed a CRESU (Cinétique de Réaction en Ecoulement Supersonique Uniforme) apparatus to attain low temperatures. The C2 species were created using pulsed laser photolysis at 193 nm of mixtures containing C2Cl4 diluted in N2, Ar, or He carrier gas. C2(X1Sigma(g)+) molecules were detected via pulsed laser-induced fluorescence in the (D1Sigma(u)+ <-- X1Sigma(g)+) system, and C2(a3Pi(u)) molecules were detected via pulsed laser-induced fluorescence in the (d 3Pi(g) <-- a 3Pi(u)) system. Relaxation of 3C2 by intersystem crossing induced by oxygen was measured at temperatures below 200 K, and it was found that this process remains very efficient in the temperature range 50-200 K. Reactivity of C2(X1Sigma(g)+) with oxygen became very inefficient below room temperature. Using these two observations, it was found to be possible to obtain the C2(X1Sigma(g)+) state alone at low temperatures by addition of a suitable concentration of O2 and then study its reactivity with NO without any interference coming from the possible relaxation of C2(a3Pi(u)) to C2(X1Sigma(g)+) induced by this reagent. The rate coefficient for reaction of C2(X1Sigma(g)+) with NO was found to be essentially constant over the temperature range 36-300 K with an average value of (1.6 +/- 0.1) x 10(-10) cm3 molecule(-1) s(-1). Reactivity of C2(a3Pi(u)) with NO was found to possess a slight negative temperature dependence over the temperature range 50-300 K, which is in very good agreement with data obtained at higher temperatures.
Observations of field-aligned currents, waves, and electric fields at substorm onset
NASA Technical Reports Server (NTRS)
Smits, D. P.; Hughes, W. J.; Cattell, C. A.; Russell, C. T.
1986-01-01
Substorm onsets, identified Pi 2 pulsations observed on the Air Force Geophysics Laboratory Magnetometer Network, are studied using magnetometer and electric field data from ISEE 1 as well as magnetometer data from the geosynchronous satellites GOES 2 and 3. The mid-latitude magnetometer data provides the means of both timing and locating the substorm onset so that the spacecraft locations with respect to the substorm current systems are known. During two intervals, each containing several onsets or intensifications, ISEE 1 observed field-aligned current signatures beginning simultaneously with the mid-latitude Pi 2 pulsation. Close to the earth broadband bursts of wave noise were observed in the electric field data whenever field-aligned currents were detected. One onset occurred when ISEE 1 and GOES 2 were on the same field line but in opposite hemispheres. During this onset ISEE 1 and GOES 2 saw magnetic signatures which appear to be due to conjugate field-aligned currents flowing out of the western end of the westward auroral electrojets. The ISEE 1 signature is of a line current moving westward past the spacecraft. During the other interval, ISEE 1 was in the near-tail region near the midnight meridian. Plasma data confirms that the plasma sheet thinned and subsequently expanded at onset. Electric field data shows that the plasma moved in the opposite direction to the plasma sheet boundary as the boundary expanded which implies that there must have been an abundant source of hot plasma present. The plasma motion was towards the center of the plasma sheet and earthwards and consisted of a series of pulses rather than a steady flow.
Collisional Removal of OH (X (sup 2)Pi, nu=7) by O2, N2, CO2, and N2O
NASA Technical Reports Server (NTRS)
Knutsen, Karen; Dyer, Mark J.; Copeland, Richard A.
1996-01-01
Collisional removal rate constants for the OH (X 2PI, nu = 7) radical are measured for the colliders O2, CO2, and N2O, and an upper limit is established for N2. OH(nu = 4) molecules, generated in a microwave discharge flow cell by the reaction of hydrogen atoms with ozone, are excited to v = 7 by the output of a pulsed infrared laser via direct vibrational overtone excitation. The temporal evolution of the P = 7 population is probed as a function of the collider gas partial pressure by a time-delayed pulsed ultraviolet laser. Fluorescence from the B 21 + state is detected in the visible spectral region.
Sawhney, Monakshi; Mehdian, Hossein; Kashin, Brian; Ip, Gregory; Bent, Maurice; Choy, Joyce; McPherson, Mark; Bowry, Richard
2016-06-01
Total knee arthroplasty is a painful surgery that requires early mobilization for successful joint function. Multimodal analgesia, including spinal analgesia, nerve blocks, periarticular infiltration (PI), opioids, and coanalgesics, has been shown to effectively manage postoperative pain. Both adductor canal (AC) and PI have been shown to manage pain without significantly impairing motor function. However, it is unclear which technique is most effective. This 3-arm trial examined the effect of AC block with PI (AC + PI) versus AC block only (AC) versus PI only (PI). The primary outcome was pain on walking at postoperative day (POD) 1. One hundred fifty-one patients undergoing unilateral total knee arthroplasty were included. Patients received either AC block with 30 mL of 0.5% ropivacaine or sham block. PI was performed intraoperatively with a 110-mL normal saline solution containing 300 mg ropivacaine, 10 mg morphine, and 30 mg ketorolac. Those patients randomly assigned to AC only received normal saline knee infiltration. On POD 1, participants who received AC + PI reported significantly lower pain numeric rating scale scores on walking (3.3) compared with those who received AC (6.2) or PI (4.9) (P < 0.0001). Participants who received AC reported significantly higher pain scores at rest and knee bend compared with those who received AC + PI or PI (P < 0.0001). The difference in pain scores between participants who received AC + PI and those who received AC was 2.83 (95% confidence interval, 1.58-4.09) and the difference between those who received AC + PI and those who received PI was 1.61 (95% confidence interval, 0.37-2.86). On POD 2, participants who received AC + PI reported significantly less pain on walking (4.4) compared with those who received AC (5.6) or PI (5.6) (P = 0.006). On POD 2, there was no difference between the groups for pain at rest or knee bending. Participants who received AC used more IV patient-controlled analgesia on POD 0. There was no difference between the groups regarding distance walked. Participants who received AC + PI reported significantly less pain on walking on PODs 1 and 2 compared with those who received AC only or PI only.
Plaut, Jennifer A; Wadsworth, W Duncan; Pangle, Robert; Yepez, Enrico A; McDowell, Nate G; Pockman, William T
2013-10-01
Global climate change is predicted to alter the intensity and duration of droughts, but the effects of changing precipitation patterns on vegetation mortality are difficult to predict. Our objective was to determine whether prolonged drought or above-average precipitation altered the capacity to respond to the individual precipitation pulses that drive productivity and survival. We analyzed 5 yr of data from a rainfall manipulation experiment in piñon-juniper (Pinus edulis-Juniperus monosperma) woodland using mixed effects models of transpiration response to event size, antecedent soil moisture, and post-event vapor pressure deficit. Replicated treatments included irrigation, drought, ambient control and infrastructure control. Mortality was highest under drought, and the reduced post-pulse transpiration in the droughted trees that died was attributable to treatment effects beyond drier antecedent conditions and reduced event size. In particular, trees that died were nearly unresponsive to antecedent shallow soil moisture, suggesting reduced shallow absorbing root area. Irrigated trees showed an enhanced response to precipitation pulses. Prolonged drought initiates a downward spiral whereby trees are increasingly unable to utilize pulsed soil moisture. Thus, the additive effects of future, more frequent droughts may increase drought-related mortality. © 2013 The Authors. New Phytologist © 2013 New Phytologist Trust.
Single-bunch synchrotron shutter
Norris, James R.; Tang, Jau-Huei; Chen, Lin; Thurnauer, Marion
1993-01-01
An apparatus for selecting a single synchrotron pulse from the millions of pulses provided per second from a synchrotron source includes a rotating spindle located in the path of the synchrotron pulses. The spindle has multiple faces of a highly reflective surface, and having a frequency of rotation f. A shutter is spaced from the spindle by a radius r, and has an open position and a closed position. The pulses from the synchrotron are reflected off the spindle to the shutter such that the speed s of the pulses at the shutter is governed by: s=4.times..pi..times.r.times.f. such that a single pulse is selected for transmission through an open position of the shutter.
High resolution time interval meter
Martin, A.D.
1986-05-09
Method and apparatus are provided for measuring the time interval between two events to a higher resolution than reliability available from conventional circuits and component. An internal clock pulse is provided at a frequency compatible with conventional component operating frequencies for reliable operation. Lumped constant delay circuits are provided for generating outputs at delay intervals corresponding to the desired high resolution. An initiation START pulse is input to generate first high resolution data. A termination STOP pulse is input to generate second high resolution data. Internal counters count at the low frequency internal clock pulse rate between the START and STOP pulses. The first and second high resolution data are logically combined to directly provide high resolution data to one counter and correct the count in the low resolution counter to obtain a high resolution time interval measurement.
NASA Astrophysics Data System (ADS)
Iwasaki, Ryosuke; Nagaoka, Ryo; Yoshizawa, Shin; Umemura, Shin-ichiro
2018-07-01
Acoustic cavitation bubbles are known to enhance the heating effect in high-intensity focused ultrasound (HIFU) treatment. The detection of cavitation bubbles with high sensitivity and selectivity is required to predict the therapeutic and side effects of cavitation, and ensure the efficacy and safety of the treatment. A pulse inversion (PI) technique has been widely used for imaging microbubbles through enhancing the second-harmonic component of echo signals. However, it has difficulty in separating the nonlinear response of microbubbles from that due to nonlinear propagation. In this study, a triplet pulse (3P) method was investigated to specifically image cavitation bubbles by extracting the 1.5th fractional harmonic component. The proposed 3P method depicted cavitation bubbles with a contrast ratio significantly higher than those in conventional imaging methods with and without PI. The results suggest that the 3P method is effective for specifically detecting microbubbles in cavitation-enhanced HIFU treatment.
VARIABLE TIME-INTERVAL GENERATOR
Gross, J.E.
1959-10-31
This patent relates to a pulse generator and more particularly to a time interval generator wherein the time interval between pulses is precisely determined. The variable time generator comprises two oscillators with one having a variable frequency output and the other a fixed frequency output. A frequency divider is connected to the variable oscillator for dividing its frequency by a selected factor and a counter is used for counting the periods of the fixed oscillator occurring during a cycle of the divided frequency of the variable oscillator. This defines the period of the variable oscillator in terms of that of the fixed oscillator. A circuit is provided for selecting as a time interval a predetermined number of periods of the variable oscillator. The output of the generator consists of a first pulse produced by a trigger circuit at the start of the time interval and a second pulse marking the end of the time interval produced by the same trigger circuit.
Sebastiani, Anne; Philippi, Larissa; Boehme, Stefan; Closhen, Dorothea; Schmidtmann, Irene; Scherhag, Anton; Markstaller, Klaus; Engelhard, Kristin; Pestel, Gunther
2012-12-01
Interscalene nerve blocks provide adequate analgesia, but there are no objective criteria for early assessment of correct catheter placement. In the present study, pulse oximetry technology was used to evaluate changes in the perfusion index (PI) in both blocked and unblocked arms, and changes in the plethysmographic variability index (PVI) were evaluated once mechanical ventilation was instituted. The PI and PVI values were assessed using a Radical-7™ finger pulse oximetry device (Masimo Corp., Irvine, CA, USA) in both arms of 30 orthopedic patients who received an interscalene catheter at least 25 min before induction of general anesthesia. Data were evaluated at baseline, on application of local anesthetics; five, ten, and 15 min after onset of interscalene nerve blocks; after induction of general anesthesia; before and after a 500 mL colloid fluid challenge; and five minutes thereafter. In the 25 patients with successful blocks, the difference between the PI values in the blocked arm and the PI values in the contralateral arm increased within five minutes of the application of the local anesthetics (P < 0.05) and increased progressively until 15 min. After induction of general anesthesia, the PI increased in the unblocked arm while it remained relatively constant in the blocked arm, thus reducing the difference in the PI. A fluid challenge resulted in a decrease in PVI values in both arms. The perfusion index increases after successful interscalene nerve blockade and may be used as an indicator for successful block placement in awake patients. The PVI values before and after a fluid challenge can be useful to detect changes in preload, and this can be performed in both blocked and unblocked arms.
Nordsmark, M.; Maxwell, R. J.; Horsman, M. R.; Bentzen, S. M.; Overgaard, J.
1997-01-01
This study has evaluated the effect of breathing 100% oxygen, carbogen and carbon monoxide (at 660 p.p.m.) on the bioenergetic and oxygenation status and the radiation response of 200-mm3 C3H mammary carcinomas grown in the feet of CDF mice. Bioenergetic status was assessed by 31P magnetic resonance spectroscopy (MRS) using a 7-tesla spectrometer with both short (2 s) and long (6 s) pulse repetition times. Tumour partial pressure of oxygen (PO2) was measured with an Eppendorf polarographic electrode; the oxygenation parameters were the median pO2 and fraction of pO2 values < or = 2.5 mmHg. The radiation response was estimated using a tumour growth delay assay (time to grow three times treatment volume). Carbon monoxide breathing decreased tumour pO2 and compromised the radiation response, but the beta-nucleoside triphosphate (NTP)/Pi ratio was unchanged. Both carbogen and oxygen (100%) increased tumour pO2 and beta-NTP/Pi and enhanced the radiation response, the effects being similar under the two gassing conditions and dependent on the gas breathing time. Thus, in this tumour model, 31P-MRS can detect hyperoxic changes, but because cells can remain metabolically active even at low oxygen tensions the beta-NTP/Pi did not correlate with low tissue oxygenation. An analysis of variance showed that gas breathing time induced a significant systematic effect on beta-NTP/Pi, the MRS pulse repetition time had a significant effect on beta-NTP/Pi change under hypoxic but not under hyperoxic conditions and the type of gas that was inhaled had a significant effect on beta-NTP/Pi. Images Figure 4 PMID:9400939
NASA Astrophysics Data System (ADS)
Yoon, Sangpil; Wang, Yingxiao; Shung, K. K.
2016-03-01
Acoustic-transfection technique has been developed for the first time. We have developed acoustic-transfection by integrating a high frequency ultrasonic transducer and a fluorescence microscope. High frequency ultrasound with the center frequency over 150 MHz can focus acoustic sound field into a confined area with the diameter of 10 μm or less. This focusing capability was used to perturb lipid bilayer of cell membrane to induce intracellular delivery of macromolecules. Single cell level imaging was performed to investigate the behavior of a targeted single-cell after acoustic-transfection. FRET-based Ca2+ biosensor was used to monitor intracellular concentration of Ca2+ after acoustic-transfection and the fluorescence intensity of propidium iodide (PI) was used to observe influx of PI molecules. We changed peak-to-peak voltages and pulse duration to optimize the input parameters of an acoustic pulse. Input parameters that can induce strong perturbations on cell membrane were found and size dependent intracellular delivery of macromolecules was explored. To increase the amount of delivered molecules by acoustic-transfection, we applied several acoustic pulses and the intensity of PI fluorescence increased step wise. Finally, optimized input parameters of acoustic-transfection system were used to deliver pMax-E2F1 plasmid and GFP expression 24 hours after the intracellular delivery was confirmed using HeLa cells.
Mashiko, Hiroki; Gilbertson, Steve; Li, Chengquan; Khan, Sabih D; Shakya, Mahendra M; Moon, Eric; Chang, Zenghu
2008-03-14
We demonstrated a novel optical switch to control the high-order harmonic generation process so that single attosecond pulses can be generated with multiple-cycle pulses. The technique combines two powerful optical gating methods: polarization gating and two-color gating. An extreme ultraviolet supercontinuum supporting 130 as was generated with neon gas using 9 fs laser pulses. We discovered a unique dependence of the harmonic spectra on the carrier-envelope phase of the laser fields, which repeats every 2 pi radians.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mashiko, Hiroki; Gilbertson, Steve; Li, Chengquan
2008-03-14
We demonstrated a novel optical switch to control the high-order harmonic generation process so that single attosecond pulses can be generated with multiple-cycle pulses. The technique combines two powerful optical gating methods: polarization gating and two-color gating. An extreme ultraviolet supercontinuum supporting 130 as was generated with neon gas using 9 fs laser pulses. We discovered a unique dependence of the harmonic spectra on the carrier-envelope phase of the laser fields, which repeats every 2{pi} radians.
Garcés-Ruiz, Mónica; Calonne-Salmon, Maryline; Plouznikoff, Katia; Misson, Coralie; Navarrete-Mier, Micaela; Cranenbrouck, Sylvie; Declerck, Stéphane
2017-01-01
A non-destructive cultivation system was developed to study the dynamics of phosphorus (Pi) uptake by mycorrhizal and non-mycorrhizal maize plantlets. The system consisted of a plant container connected via silicon tubes to a glass bottle containing a nutrient solution supplemented with Pi. The nutrient solution is pumped with a peristaltic pump to the upper part of the container via the silicon tubes and the solution percolate through the plantlet container back into the glass bottle. Pi is sampled from the glass bottle at regular intervals and concentration evaluated. Maize plantlets were colonized by the AMF Rhizophagus irregularis MUCL 41833 and Pi uptake quantified at fixed intervals (9, 21, and 42 h) from the depletion of the Pi in the nutrient solution flowing through the plantlets containers. Plants and fungus grew well in the perlite substrate. The concentration of Pi in the bottles followed an almost linear decrease over time, demonstrating a depletion of Pi in the circulating solution and a concomitant uptake/immobilization by the plantlet-AMF associates in the containers. The Pi uptake rate was significantly increased in the AMF-colonized plantlets (at 9 and 21 h) as compared to non-colonized plantlets, although no correlation was noticed with plant growth or P accumulation in shoots. The circulatory semi-hydroponic cultivation system developed was adequate for measuring Pi depletion in a nutrient solution and by corollary Pi uptake/immobilization by the plant-AMF associates. The measurements were non-destructive so that the time course of Pi uptake could be monitored without disturbing the growth of the plant and its fungal associate. The system further opens the door to study the dynamics of other micro and macro-nutrients as well as their uptake under stressed growth conditions such as salinity, pollution by hydrocarbon contaminants or potential toxic elements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zou Pu; Zeng Zhinan; Zheng Yinghui
2010-11-15
We propose a scheme for generating isolated attosecond pulse (IAP) via high-order harmonic generation in gases using a chirped two-color laser field of multicycle duration. In contrast to previous techniques where the stable carrier-envelope phase (CEP) of the driving laser pulses is a prerequisite for IAP generation, the proposed scheme is robust against the large variation of CEP. We show the generation of IAP with an intensity fluctuation less than 50% and an intensity contrast ratio higher than 5:1 when the CEP shift is as large as 1.35{pi}.
NASA Astrophysics Data System (ADS)
Frissell, N. A.; Baker, J. B. H.; Ruohoniemi, J. M.; Clausen, L. B. N.; Kale, Z. C.; Rae, I. J.; Kepko, L.; Oksavik, K.; Greenwald, R. A.; West, M. L.
2011-01-01
Recent expansion of the SuperDARN network to mid-latitudes and the addition of a new high-time resolution mode provides new opportunities to observe mid-latitude ultra-low frequency waves and other ionospheric sub-auroral features at high temporal resolution. On 22 February 2008, the Blackstone SuperDARN radar and THEMIS ground magnetometers simultaneously observed substorm Pi2 pulsations. Similarities in measurements from the Blackstone radar and a magnetometer at Remus suggest a common generating mechanism. Cross-phase analysis of magnetometer data places these measurements at the ionospheric projection of the plasmapause, while fine spatial and temporal details of the radar data show evidence of field line compressions. About 1 min prior to ground Pi2 observation, 2 Earthward-moving Bursty Bulk Flows (BBFs) were observed by THEMIS probes D and E in the near-Earth plasma sheet. We conclude that the first 2 pulses of the Pi2s observed at Blackstone and Remus result from compressional energy generated by BBFs braking against the magnetospheric dipolar region.
Non-invasively estimated ICP pulse amplitude strongly correlates with outcome after TBI.
Budohoski, Karol P; Schmidt, Bernhard; Smielewski, Peter; Kasprowicz, Magdalena; Plontke, Ronny; Pickard, John D; Klingelhöfer, Jurgen; Czosnyka, Marek
2012-01-01
An existing monitoring database of brain signal recordings in patients with head injury has been re-evaluated with regard to the accuracy of estimation of non-invasive ICP (nICP) and its components, with a particular interest in the implications for outcome after head injury. Middle cerebral artery blood flow velocity (FV), ICP and arterial blood pressure (ABP) were recorded. Non-invasive ICP (nICP) was calculated using a mathematical model. Other signals analysed included components of ICP (n" indicates non-invasive): ICP pulse amplitude (Amp, nAmp), amplitude of the respiratory component (Resp, nResp), amplitude of slow vasogenic waves of ICP (Slow, nSlow) and index of compensatory reserve (RAP, nRAP). Mean values of analysed signals were compared against each other and between patients who died and survived. The correlation between ICP and nICP was moderately strong, R = 0.51 (95% prediction interval [PI] 17 mm Hg). The components of nICP and ICP were also moderately correlated with each other: the strongest correlation was observed for Resp vs. nResp (r = 0.66), while weaker for Amp vs. nAmp (r = 0.41). Non-invasive pulse amplitude of ICP showed the strongest association with outcome, with the -difference between those who survived and those who died reaching a significance level of p < 0.000001. When compared between patients who died and who survived mean nAmp showed the greatest difference, suggesting its potential to predict mortality after TBI.
Baek, Hyun Jae; Shin, JaeWook
2017-08-15
Most of the wrist-worn devices on the market provide a continuous heart rate measurement function using photoplethysmography, but have not yet provided a function to measure the continuous heart rate variability (HRV) using beat-to-beat pulse interval. The reason for such is the difficulty of measuring a continuous pulse interval during movement using a wearable device because of the nature of photoplethysmography, which is susceptible to motion noise. This study investigated the effect of missing heart beat interval data on the HRV analysis in cases where pulse interval cannot be measured because of movement noise. First, we performed simulations by randomly removing data from the RR interval of the electrocardiogram measured from 39 subjects and observed the changes of the relative and normalized errors for the HRV parameters according to the total length of the missing heart beat interval data. Second, we measured the pulse interval from 20 subjects using a wrist-worn device for 24 h and observed the error value for the missing pulse interval data caused by the movement during actual daily life. The experimental results showed that mean NN and RMSSD were the most robust for the missing heart beat interval data among all the parameters in the time and frequency domains. Most of the pulse interval data could not be obtained during daily life. In other words, the sample number was too small for spectral analysis because of the long missing duration. Therefore, the frequency domain parameters often could not be calculated, except for the sleep state with little motion. The errors of the HRV parameters were proportional to the missing data duration in the presence of missing heart beat interval data. Based on the results of this study, the maximum missing duration for acceptable errors for each parameter is recommended for use when the HRV analysis is performed on a wrist-worn device.
NASA Technical Reports Server (NTRS)
Ito, Kazufumi
1987-01-01
The linear quadratic optimal control problem on infinite time interval for linear time-invariant systems defined on Hilbert spaces is considered. The optimal control is given by a feedback form in terms of solution pi to the associated algebraic Riccati equation (ARE). A Ritz type approximation is used to obtain a sequence pi sup N of finite dimensional approximations of the solution to ARE. A sufficient condition that shows pi sup N converges strongly to pi is obtained. Under this condition, a formula is derived which can be used to obtain a rate of convergence of pi sup N to pi. The results of the Galerkin approximation is demonstrated and applied for parabolic systems and the averaging approximation for hereditary differential systems.
Autonomic modulation of arterial pressure and heart rate variability in hypertensive diabetic rats.
Farah, Vera de Moura Azevedo; De Angelis, Kátia; Joaquim, Luis Fernando; Candido, Georgia O; Bernardes, Nathalia; Fazan, Rubens; Schaan, Beatriz D'Agord; Irigoyen, Maria-Claudia
2007-08-01
The aim of the present study was to evaluate the autonomic modulation of the cardiovascular system in streptozotocin (STZ)-induced diabetic spontaneously hypertensive rats (SHR), evaluating baroreflex sensitivity and arterial pressure and heart rate variability. Male SHR were divided in control (SHR) and diabetic (SHR+DM, 5 days after STZ) groups. Arterial pressure (AP) and baroreflex sensitivity (evaluated by tachycardic and bradycardic responses to changes in AP) were monitored. Autoregressive spectral estimation was performed for systolic AP (SAP) and pulse interval (PI) with oscillatory components quantified as low (LF:0.2-0.6Hz) and high (HF:0.6-3.0Hz) frequency ranges. Mean AP and heart rate in SHR+DM (131+/-3 mmHg and 276+/-6 bpm) were lower than in SHR (160+/-7 mmHg and 330+/-8 bpm). Baroreflex bradycardia was lower in SHR+DM as compared to SHR (0.55+/-0.1 vs. 0.97+/-0.1 bpm/mmHg). Overall SAP variability in the time domain (standard deviation of beat-by-beat time series of SAP) was lower in SHR+DM (3.1+/-0.2 mmHg) than in SHR (5.7+/-0.6 mmHg). The standard deviation of the PI was similar between groups. Diabetes reduced the LF of SAP (3.3+/-0.8 vs. 28.7+/-7.6 mmHg2 in SHR), while HF of SAP were unchanged. The power of oscillatory components of PI did not differ between groups. These results show that the association of hypertension and diabetes causes an impairment of the peripheral cardiovascular sympathetic modulation that could be, at least in part, responsible for the reduction in AP levels. Moreover, this study demonstrates that diabetes might actually impair the reduced buffer function of the baroreceptors while reducing blood pressure.
Sabino, João Paulo J; da Silva, Carlos Alberto Aguiar; de Melo, Rubens Fernando; Fazan, Rubens; Salgado, Helio C
2013-01-01
Sympathetic hyperactivity and its outcome in heart failure have been thoroughly investigated to determine the focus of pharmacologic approaches targeting the sympathetic nervous system in the treatment of this pathophysiological condition. On the other hand, therapeutic approaches aiming to protect the reduced cardiac parasympathetic function have not received much attention. The present study evaluated rats with chronic heart failure (six to seven weeks after coronary artery ligation) and the effects of an increased parasympathetic function by pyridostigmine (an acetylcholinesterase inhibitor) on the following aspects: arterial pressure (AP), heart rate (HR), baroreceptor and Bezold-Jarisch reflex, pulse interval (PI) and AP variability, cardiac sympathetic and parasympathetic tonus, intrinsic heart rate (i-HR) and cardiac function. Conscious rats with heart failure exhibited no change in HR, Bezold-Jarisch reflex, PI variability and cardiac sympathetic tonus. On the other hand, these animals presented hypotension and reduced baroreflex sensitivity, power in the low frequency (LF) band of the systolic AP spectrum, cardiac parasympathetic tonus and i-HR, while anesthetized rats exhibited reduced cardiac performance. Pyridostigmine prevented the attenuation of all the parameters examined, except basal AP and cardiac performance. In conclusion, the blockade of acetylcholinesterase with pyridostigmine was revealed to be an important pharmacological approach, which could be used to increase parasympathetic function and to improve a number of cardiocirculatory parameters in rats with heart failure. Copyright © 2012 Elsevier B.V. All rights reserved.
Nuccio, Vito F.; Condon, Steven M.
1996-01-01
The Ismay?Desert Creek interval and Cane Creek cycle of the Alkali Gulch interval of the Middle Pennsylvanian Paradox Formation in the Paradox Basin of Utah and Colorado contain excellent organic-rich source rocks having total organic carbon contents ranging from 0.5 to 11.0 percent. The source rocks in both intervals contain types I, II, and III organic matter and are potential source rocks for both oil and gas. Organic matter in the Ismay?Desert Creek interval and Cane Creek cycle of the Alkali Gulch interval (hereinafter referred to in this report as the ?Cane Creek cycle?) probably is more terrestrial in origin in the eastern part of the basin and is interpreted to have contributed to some of the gas produced there. Thermal maturity increases from southwest to northeast for both the Ismay?Desert Creek interval and Cane Creek cycle, following structural and burial trends throughout the basin. In the northernmost part of the basin, the combination of a relatively thick Tertiary sedimentary sequence and high basinal heat flow has produced very high thermal maturities. Although general thermal maturity trends are similar for both the Ismay?Desert Creek interval and Cane Creek cycle, actual maturity levels are higher for the Cane Creek due to the additional thickness (as much as several thousand feet) of Middle Pennsylvanian section. Throughout most of the basin, the Ismay?Desert Creek interval is mature and in the petroleum-generation window (0.10 to 0.50 production index (PI)), and both oil and gas are produced; in the south-central to southwestern part of the basin, however, the interval is marginally mature (0.10 PI) in the central part of the basin and is overmature (past the petroleum-generation window (>0.50 PI)) throughout most of the eastern part of the basin. The Cane Creek cycle generally produces oil and associated gas throughout the western and central parts of the basin and thermogenic gas in the eastern part of the basin. Burial and thermal-history models were constructed for six different areas of the Paradox Basin. In the Monument upwarp area, the least mature part of the basin, the Ismay?Desert Creek interval and Cane Creek cycle have thermal maturities of 0.10 and 0.20 PI and were buried to 13,400 ft and 14,300 ft, respectively. A constant heat flow through time of 40 mWm?2 (milliwatts per square meter) is postulated for this area. Significant petroleum generation began at 45 Ma for the Ismay?Desert Creek interval and at 69 Ma for the Cane Creek cycle. In the area around the confluence of the Green and Colorado Rivers, the Ismay?Desert Creek interval and Cane Creek cycle have thermal maturities of 0.20 and 0.25 PI and were buried to 13,000 ft and 14,200 ft, respectively. A constant heat flow through time of 42 mWm?2 is postulated for this area. Significant petroleum generation began at 60 Ma for the Ismay?Desert Creek interval and at 75 Ma for the Cane Creek cycle. In the area around the town of Green River, Utah, the Ismay?Desert Creek interval and Cane Creek cycle have thermal maturities of 0.60 and greater and were buried to 14,000 ft and 15,400 ft, respectively. A constant heat flow through time of 53 mWm?2 is proposed for this area. Significant petroleum generation began at 82 Ma for the Ismay?Desert Creek interval and at 85 Ma for the Cane Creek cycle. Around Moab, Utah, in the deeper, eastern part of the basin, the Ismay?Desert Creek interval and Cane Creek cycle have thermal maturities of 0.30 and around 0.35 PI and were buried to 18,250 ft and 22,000 ft, respectively. A constant heat flow through time of 40 mWm?2 is postulated for this area. Significant petroleum generation began at 79 Ma for the Ismay?Desert Creek interval and at 90 Ma for the Cane Creek cycle. At Lisbon Valley, also in the structurally deeper part of the basin, the Ismay?
Idowu, O E; Apemiye, R A
2009-08-01
Sixty-three adult patients with intracranial neoplasms were studied prospectively over a 2 year period. The various factors related to pre-presentation symptoms interval (PSI) and pre-diagnostic interval (PI) were noted. The mean age at presentation for all patients was 46.8 years (range 18-72 years, median 46 years). Meningiomas (30%), Pituitary tumours (18%), High-grade gliomas (14%) and craniopharyngiomas (8%) were the most common brain tumours. The median PSI of all patients was 2 year (range 2 months-5 years) with a PI of 4 weeks (range 0-8 months). The PSI and PI were longer for women with a statistical significance between the PSI and gender (p=0.016). The tumour grade was significantly correlated with PSI (p=0.000) and PI (p=0.043). Late presentation and diagnosis were due to cultural and religious beliefs compounded by self medication and financial constraint. There is the need for widespread mass enlightenment, improvement in accessibility and affordability of neuroimaging facilities coupled with subsidization of treatment.
Facilitation and refractoriness of the electrically evoked compound action potential.
Hey, Matthias; Müller-Deile, Joachim; Hessel, Horst; Killian, Matthijs
2017-11-01
In this study we aim to resolve the contributions of facilitation and refractoriness at very short pulse intervals. Measurements of the refractory properties of the electrically evoked compound action potential (ECAP) of the auditory nerve in cochlear implant (CI) users at inter pulse intervals below 300 μs are influenced by facilitation and recovery effects. ECAPs were recorded using masker pulses with a wide range of current levels relative to the probe pulse levels, for three suprathreshold probe levels and pulse intervals from 13 to 200 μs. Evoked potentials were measured for 21 CI patients by using the masked response extraction artifact cancellation procedure. During analysis of the measurements the stimulation current was not used as absolute value, but in relation to the patient's individual ECAP threshold. This enabled a more general approach to describe facilitation as a probe level independent effect. Maximum facilitation was found for all tested inter pulse intervals at masker levels near patient's individual ECAP threshold, independent from probe level. For short inter pulse intervals an increased N 1 P 1 amplitude was measured for subthreshold masker levels down to 120 CL below patient's individual ECAP threshold in contrast to the recreated state. ECAPs recorded with inter pulse intervals up to 200 μs are influenced by facilitation and recovery. Facilitation effects are most pronounced for masker levels at or below ECAP threshold, while recovery effects increase with higher masker levels above ECAP threshold. The local maximum of the ECAP amplitude for masker levels around ECAP threshold can be explained by the mutual influence of maximum facilitation and minimal refractoriness. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Few-cycle carrier envelope phase-dependent stereo detection of electrons.
Verhoef, Aart J; Fernández, Alma; Lezius, Matthias; O'Keeffe, Kevin; Uiberacker, Matthias; Krausz, Ferenc
2006-12-01
The spatial distribution of electrons emitted from atoms by few-cycle optical fields is known to be dependent on the carrier envelope phase, i.e., the phase of the field with respect to the pulse envelope. With respect to Paulus et al. [Phys. Rev. Lett.91, 253004 (2003)] we propose a greatly simplified device to measure and control the carrier envelope phase of few-cycle pulses with an accuracy of better than pi/10 based on this principle. We compared different schemes to control the carrier envelope phase of our pulses.
Van Vlack, C; Hughes, S
2007-04-20
Ultrashort pulse light-matter interactions in a semiconductor are investigated within the regime of resonant optical rectification. Using pulse envelope areas of around 1.5-3.5 pi, a single-shot dependence on carrier-envelope-offset phase (CEP) is demonstrated for 5 fs pulse durations. A characteristic phase map is predicted for several different frequency regimes using parameters for thin-film GaAs. We subsequently suggest a possible technique to extract the CEP, in both sign and amplitude, using a solid state detector.
Selective RF pulses in NMR and their effect on coupled and uncoupled spin systems
NASA Astrophysics Data System (ADS)
Slotboom, J.
1993-10-01
This thesis describes various aspects of the usage of shaped RF-pulses for volume selection and spectral editing. Contents: Introduction--The History of Magnetic Resonance in a Nutshell, and The Usage of RF Pulses in Contemporary MRS and MRI; Theoretical and Practical Aspects of Localized NMR Spectroscopy; The Effects of RF Pulse Shape Discretization on the Spatially Selective Performance; Design of Frequency-Selective RF Pulses by Optimizing a Small Number of Pulse Parameters; A Single-Shot Localization Pulse Sequence Suited for Coils with Inhomogeneous RF Fields Using Adiabatic Slice-Selective RF Pulses; The Bloch Equations for an AB System and the Design of Spin State Selective RF Pulses for Coupled Spin Systems; The Effects of Frequency Selective RF Pulses on J Coupled Spin-1/2 Systems; A Quantitative (1)H MRS in vivo Study of the Effects of L-Ornithine-L-Aspartate on the Development of Mild Encephalopathy Using a Single Shot Localization Technique Based on SAR Reduced Adiabatic 2(pi) Pulses.
Swept Line Electron Beam Annealing of Ion Implanted Semiconductors.
1982-07-01
of my research to the mainstream of technology. The techniques used for beam processing are distinguished by their * ~.* beam source and method by...raster scanned CW lasers (CWL), pulsed ion beams (PI), area pulsed electron beams (PEE), raster scanned (RSEB) or multi - scanned electron beams (MSEB...where high quality or tailored profiles are required. Continuous wave lasers and multi -scanned or swept-line electron beams are the most likely candidates
Enhancing the Area of a Raman Atom Interferometer Using a Versatile Double-Diffraction Technique
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leveque, T.; Gauguet, A.; Michaud, F.
2009-08-21
In this Letter, we demonstrate a new scheme for Raman transitions which realize a symmetric momentum-space splitting of 4(Planck constant/2pi)k, deflecting the atomic wave packets into the same internal state. Combining the advantages of Raman and Bragg diffraction, we achieve a three pulse state labeled an interferometer, intrinsically insensitive to the main systematics and applicable to all kinds of atomic sources. This splitting scheme can be extended to 4N(Planck constant/2pi)k momentum transfer by a multipulse sequence and is implemented on a 8(Planck constant/2pi)k interferometer. We demonstrate the area enhancement by measuring inertial forces.
Tipene-Leach, David; Baddock, Sally A; Williams, Sheila M; Tangiora, Angeline; Jones, Raymond; McElnay, Caroline; Taylor, Barry J
2018-06-01
The aim of this study was to identify the potential risks and benefits of sleeping infants in a Pēpi-Pod distributed to families with high risk of sudden unexpected death in infancy compared to a bassinet. Forty-five mostly indigenous Māori mothers who were referred by local health providers to receive a Pēpi-Pod were surveyed at recruitment, 1 and 3 months. A sleep study at 1 month included infrared video, oximetry and temperature measures. When compared with 89 historical bassinet controls, an intention-to-treat analysis of questionnaires showed no increase in direct bed sharing but demonstrated significantly less sharing of the maternal bedroom at both interviews, with the majority of those not sleeping in the maternal bedroom, actually sleeping in the living room. The 1 month 'as-used' analysis showed poorer maternal sleep quality. The 'as-used' analysis of video data (24 Pēpi-Pod and 113 bassinet infants) also showed no increase in direct bed sharing, head covering or prone/side sleep position. Differences in oxygen saturation were not significant, but heart rate was higher in the Pēpi-Pod infants by 8.37 bpm (95% confidence interval 4.40, 12.14). Time in the thermal comfort zone was not different between groups despite Pēpi-Pod infants being situated in significantly warmer rooms. Overall, we found that most differences in infant risk behaviours in a Pēpi-Pod compared to a bassinet were small, with confidence intervals excluding meaningful differences. We noted poorer maternal sleep quality at 1 month. Higher infant heart rates in the Pēpi-Pod group may be related to higher room temperatures. The Pēpi-Pod appears physiologically safe but is associated with lower reported maternal sleep quality. © 2018 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).
High resolution time interval counter
Condreva, Kenneth J.
1994-01-01
A high resolution counter circuit measures the time interval between the occurrence of an initial and a subsequent electrical pulse to two nanoseconds resolution using an eight megahertz clock. The circuit includes a main counter for receiving electrical pulses and generating a binary word--a measure of the number of eight megahertz clock pulses occurring between the signals. A pair of first and second pulse stretchers receive the signal and generate a pair of output signals whose widths are approximately sixty-four times the time between the receipt of the signals by the respective pulse stretchers and the receipt by the respective pulse stretchers of a second subsequent clock pulse. Output signals are thereafter supplied to a pair of start and stop counters operable to generate a pair of binary output words representative of the measure of the width of the pulses to a resolution of two nanoseconds. Errors associated with the pulse stretchers are corrected by providing calibration data to both stretcher circuits, and recording start and stop counter values. Stretched initial and subsequent signals are combined with autocalibration data and supplied to an arithmetic logic unit to determine the time interval in nanoseconds between the pair of electrical pulses being measured.
High resolution time interval counter
Condreva, K.J.
1994-07-26
A high resolution counter circuit measures the time interval between the occurrence of an initial and a subsequent electrical pulse to two nanoseconds resolution using an eight megahertz clock. The circuit includes a main counter for receiving electrical pulses and generating a binary word--a measure of the number of eight megahertz clock pulses occurring between the signals. A pair of first and second pulse stretchers receive the signal and generate a pair of output signals whose widths are approximately sixty-four times the time between the receipt of the signals by the respective pulse stretchers and the receipt by the respective pulse stretchers of a second subsequent clock pulse. Output signals are thereafter supplied to a pair of start and stop counters operable to generate a pair of binary output words representative of the measure of the width of the pulses to a resolution of two nanoseconds. Errors associated with the pulse stretchers are corrected by providing calibration data to both stretcher circuits, and recording start and stop counter values. Stretched initial and subsequent signals are combined with autocalibration data and supplied to an arithmetic logic unit to determine the time interval in nanoseconds between the pair of electrical pulses being measured. 3 figs.
Jang, Hee Won; Chun, Seung Hyun; Park, Hae Chul; Ryu, Hwa Jung; Kim, Il-Hwan
2017-04-01
Recently dual-pulsed low-fluence 1064-nm Q-switched Nd:YAG (QSNY) laser has been developed for reducing complication during melasma treatment. Comparison of the efficacy and safety between dual-pulsed mode and single-pulsed mode for the treatment of melasma. In preclinical study, adult zebrafish were irradiated with dual-pulsed and single-pulsed mode. Changes of melanophore and cell death were assessed. In split-face clinical study, dual-pulsed and single-pulsed mode were irradiated on the left and right side of the face, respectively. L* value, clinical digital photos, modified Melasma Area and Severity Index (MASI) scores, and side effects were measured. As compared to single-pulsed mode and dual-pulsed mode with longer intervals, zebrafish melanophore was cleared quickly at dual-pulsed mode with 80-μsec interval and 0.3 J/cm 2 fluence. Dual-pulsed mode showed the least regeneration of melanophore at 4 weeks after irradiation and no cell death was observed with 80-μsec interval. Both pulse modes improved melasma significantly but modified MASI score and L* value were not significantly different between each other. Lesser pain and shorter duration of post-laser erythema were observed with dual-pulsed mode. Dual-pulsed mode was as effective as single-pulsed mode for the treatment of melasma and revealed less side effects.
NASA Astrophysics Data System (ADS)
Steelman, Zachary A.; Tolstykh, Gleb P.; Beier, Hope T.; Ibey, Bennett L.
2016-03-01
Cells exposed to nanosecond-pulsed electric fields (nsPEF) exhibit a wide variety of nonspecific effects, including blebbing, swelling, intracellular calcium bursts, apoptotic and necrotic cell death, formation of nanopores, and depletion of phosphatidylinositol 4,5-biphosphate (PIP2) to induce activation of the inositol trisphosphate/diacylglycerol pathway. While several studies have taken place in which multiple pulses were delivered to cells, the effect of pulse repetition rate (PRR) is not well understood. To better understand the effects of PRR, a laser scanning confocal microscope was used to observe CHO-K1 cells exposed to ten 600ns, 200V pulses at varying repetition rates (5Hz up to 500KHz) in the presence of either FM 1-43, YO-PRO-1, or Propidium Iodide (PI) fluorescent dyes, probes frequently used to indicate nanoporation or permeabilization of the plasma membrane. Dye uptake was monitored for 30 seconds after pulse application at a rate of 1 image/second. In addition, a single long pulse of equivalent energy (200V, 6 μs duration) was applied to test the hypothesis that very fast PRR will approximate the biological effects of a single long pulse of equal energy. Upon examination of the data, we found strong variation in the relationship between PRR and uptake in each of the three dyes. In particular, PI uptake showed little frequency dependence, FM 1-43 showed a strong inverse relationship between frequency and internal cell fluorescence, and YO-PRO-1 exhibited a "threshold" point of around 50 KHz, after which the inverse trend observed in FM 1-43 was seen to reverse itself. Further, a very high PRR of 500 KHz only approximated the biological effects of a single 6 μs pulse in cells stained with YO-PRO-1, suggesting that uptake of different dyes may proceed by different physical mechanisms.
Fine Mapping of Resistance Genes from Five Brown Stem Rot Resistance Sources in Soybean.
Rincker, Keith; Hartman, Glen L; Diers, Brian W
2016-03-01
Brown stem rot (BSR) of soybean [ (L.) Merr.] caused by (Allington & Chamb.) T.C. Harr. & McNew can be controlled effectively with genetic host resistance. Three BSR resistance genes , , and , have been identified and mapped to a large region on chromosome 16. Marker-assisted selection (MAS) will be more efficient and gene cloning will be facilitated with a narrowed genomic interval containing an gene. The objective of this study was to fine map the positions of genes from five sources. Mapping populations were developed by crossing the resistant sources 'Bell', PI 84946-2, PI 437833, PI 437970, L84-5873, and PI 86150 with either the susceptible cultivar Colfax or Century 84. Plants identified as having a recombination event near genes were selected and individually harvested to create recombinant lines. Progeny from recombinant lines were tested in a root-dip assay and evaluated for foliar and stem BSR symptom development. Overall, 4878 plants were screened for recombination, and progeny from 52 recombinant plants were evaluated with simple-sequence repeat (SSR) genetic markers and assessed for symptom development. Brown stem rot resistance was mapped to intervals ranging from 0.34 to 0.04 Mb in the different sources. In all sources, resistance was fine mapped to intervals inclusive of BARCSOYSSR_16_1114 and BARCSOYSSR_16_1115, which provides further evidence that one locus provides BSR resistance in soybean. Copyright © 2016 Crop Science Society of America.
Echo tracker/range finder for radars and sonars
NASA Technical Reports Server (NTRS)
Constantinides, N. J. (Inventor)
1982-01-01
An echo tracker/range finder or altimeter is described. The pulse repetition frequency (PFR) of a predetermined plurality of transmitted pulses is adjusted so that echo pulses received from a reflecting object are positioned between transmitted pulses and divided their interpulse time interval into two time intervals having a predetermined ratio with respect to each other. The invention described provides a means whereby the arrival time of a plurality of echo pulses is defined as the time at which a composite echo pulse formed of a sum of the individual echo pulses has the highest amplitude. The invention is applicable to radar systems, sonar systems, or any other kind of system in which pulses are transmitted and echoes received therefrom.
NASA Astrophysics Data System (ADS)
Furukawa, Yuki; Sakata, Ryoichi; Konishi, Kazuki; Ono, Koki; Matsuoka, Shusaku; Watanabe, Kota; Inoue, Shunsuke; Hashida, Masaki; Sakabe, Shuji
2016-06-01
By pairing femtosecond laser pulses (duration ˜40 fs and central wavelength ˜810 nm) at an appropriate time interval, a laser-induced periodic surface structure (LIPSS) is formed with much less ablation than one formed with a single pulse. On a titanium plate, a pair of laser pulses with fluences of 70 and 140 mJ/cm2 and a rather large time interval (>10 ps) creates a LIPSS with an interspace of 600 nm, the same as that formed by a single pulse of 210 mJ/cm2, while the double pulse ablates only 4 nm, a quarter of the ablation depth of a single pulse.
Detailed characteristics of intermittent current pulses due to positive corona
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Yang, E-mail: liuyangwuh520@sina.com; Cui, Xiang; Lu, Tiebing
In order to get detailed characteristics of intermittent current pulses due to positive corona such as the repetition rate of burst-pulse trains, the peak value ratio of the primary pulse to the secondary pulse, the number of pulses per burst, and the interval of the secondary pulses, a systematic study was carried out in a coaxial conductor-cylinder electrode system with the conductor electrode being set with a discharge point. Empirical formulae for the number of pulses per burst and the interval of the secondary pulses are first presented. A theoretical model based on the motion of the space-charge clouds ismore » proposed. Analysis with the model gives explanations to the experimental results and reveals some new insights into the physical mechanism of positive intermittent corona.« less
Guo, Y Q; Bhattacharya, A; Bernstein, E R
2009-01-08
Photodissociation of nitromethane has been investigated for decades both theoretically and experimentally; however, as a whole picture, the dissociation dynamics for nitromethane are still not clear, although many different mechanisms have been proposed. To make a complete interpretation of these different mechanisms, photolysis of nitromethane at 226 and 271 nm under both collisional and collisionless conditions is investigated at nanosecond and femtosecond time scales. These two laser wavelengths correspond to the pi* <-- pi and pi* <-- n excitations of nitromethane, respectively. In nanosecond 226 nm (pi* <-- pi) photolysis experiments, CH(3) and NO radicals are observed as major products employing resonance enhanced multiphoton ionization techniques and time-of-flight mass spectrometry. Additionally, OH and CH(3)O radicals are weakly observed as dissociation products employing laser induced fluorescence spectroscopy; the CH(3)O product is only observed under collisional conditions. In femtosecond 226 nm experiments, CH(3), NO(2), and NO products are observed. These results confirm that rupture of C-N bond should be the main primary process for the photolysis of nitromethane after the pi* <-- pi excitation at 226 nm, and the NO(2) molecule should be the precursor of the observed NO product. Formation of the CH(3)O radical after the recombination of CH(3) and NO(2) species under collisional conditions rules out a nitro-nitrite isomerization mechanism for the generation of CH(3)O and NO from pi pi* CH(3)NO(2). The OH radical formation for pi pi* CH(3)NO(2) should be a minor dissociation channel because of the weak OH signal in both nanosecond and femtosecond (nonobservable) experiments. Single color femtosecond pump-probe experiments at 226 nm are also employed to monitor the dynamics of the dissociation of nitromethane after the pi* <-- pi excitation. Because of the ultrafast dynamics of product formation at 226 nm, the pump-probe transients for the three dissociation products are measured as an autocorrelation of the laser pulse, indicating the dissociation of nitromethane in the pi pi* excited state is faster than the laser pulse duration (180 fs). In nanosecond 271 nm (pi* <-- n) photolysis experiments, pump-probe experiments are performed to detect potential dissociation products, such as CH(3), NO(2), CH(3)O, and OH; however, none of them is observed. In femtosecond 271 nm laser experiments, the nitromethane parent ion is observed with major intensity, together with CH(3), NO(2), and NO fragment ions with only minor intensities. Pump-probe transients for both nitromethane parent and fragment ions at 271 nm excitation and 406.5 nm ionization display a fast exponential decay with a constant time of 36 fs, which we suggest to be the lifetime of the excited n pi* state of nitromethane. Combined with the 271 nm nanosecond pump-probe experiments, in which none of the CH(3), NO(2), CH(3)O, or OH fragment is observed, we suggest that all the fragment ions generated in 271 nm femtosecond laser experiments are derived from the parent ion, and dissociation of nitromethane from the n pi* excited electronic state does not occur in a supersonic molecular beam under collisionless conditions.
Pulsed Electric Fields for Biological Weapons Defense
2008-09-30
multifunctional biological transporters and near - infrared agents for selective cancer cell destruction. Proc Natl Acad Sci U S A 102, 11600-5. 45. Heller, D. A...controlled biochemical manipulation. Nanotechnology 14,551-556. 47. Cherukuri, P., Bachilo, S. M., Litovsky, S. H., and Weisman, R. B. (2004). Near - infrared ...Pulsed Electric Fields for Biological Weapons Defense AFOSR Grant No. FA9550-05-1-0081 P.I. Martin Gundersen atrophaeus and isolates from dental patients
Observation of hard X-rays from the Crab pulsar and A0535+26
NASA Technical Reports Server (NTRS)
Wu, M.; Dai, C.; Lu, Z.; Ma, Y.; Li, G.; Fan, Z.; Zhang, C.; Xu, C.; Zhang, X.; Gu, Y.
1985-01-01
The Crab pulsar PSR0531+21 was observed in a balloon flight from the Xianghe Balloon Station (China). Data were obtained in the range 20 to 200 keV with a poswish hard X-ray telescope which comprised a 150 sq cm primary crystal of 5 mm thick CsI(T1) which actively shielded the lower 2 pi steradians by a 5 cm thick NaI(T1) crystal. The scintillation pulses originating in CsI and NaI crystals are distinguished by pulse shape discrimination. The telescope has a field of view of approximately 4 deg H psi H pi determined by graded shield and collimator. The effective geometric area of the detector is 116 sq cm. It is noted that when folding a data flow on a long period interference from the data acquisition, transmission and recording system considerably affect the result.
Annual Progress Report FY-82. Volume I.
1982-01-01
Comparison of Binaural Versus 316 Monaural Amplification. (FY-81PI) 2535 Development of Method for Generating 318 Individualized Aural Rehabilitation...Oncology Group. 428 (FY-74 I ) 4116 The Evaluation of Petal Systolic Time Intervals 429 and Beat interval Variation in Fetal heart Rate as Early
Electronic circuit delivers pulse of high interval stability
NASA Technical Reports Server (NTRS)
Fisher, B.
1966-01-01
Circuit generates a pulse of high interval stability with a complexity level considerably below systems of comparable stability. This circuit is being used as a linear frequency discriminator in the signal conditioner of the Apollo command module.
Selective Attention in Pigeon Temporal Discrimination.
Subramaniam, Shrinidhi; Kyonka, Elizabeth
2017-07-27
Cues can vary in how informative they are about when specific outcomes, such as food availability, will occur. This study was an experimental investigation of the functional relation between cue informativeness and temporal discrimination in a peak-interval (PI) procedure. Each session consisted of fixed-interval (FI) 2-s and 4-s schedules of food and occasional, 12-s PI trials during which pecks had no programmed consequences. Across conditions, the phi (ϕ) correlation between key light color and FI schedule value was manipulated. Red and green key lights signaled the onset of either or both FI schedules. Different colors were either predictive (ϕ = 1), moderately predictive (ϕ = 0.2-0.8), or not predictive (ϕ = 0) of a specific FI schedule. This study tested the hypothesis that temporal discrimination is a function of the momentary conditional probability of food; that is, pigeons peck the most at either 2 s or 4 s when ϕ = 1 and peck at both intervals when ϕ < 1. Response distributions were bimodal Gaussian curves; distributions from red- and green-key PI trials converged when ϕ ≤ 0.6. Peak times estimated by summed Gaussian functions, averaged across conditions and pigeons, were 1.85 s and 3.87 s, however, pigeons did not always maximize the momentary probability of food. When key light color was highly correlated with FI schedules (ϕ ≥ 0.6), estimates of peak times indicated that temporal discrimination accuracy was reduced at the unlikely interval, but not the likely interval. The mechanism of this reduced temporal discrimination accuracy could be interpreted as an attentional process.
Coutu, Paige; Caulkett, Nigel; Pang, Daniel; Boysen, Søren
2015-09-01
Hypoxemia is common during equine field anesthesia. Our hypothesis was that oxygen therapy from a portable oxygen concentrator would increase PaO2 during field anesthesia compared with the breathing of ambient air. Prospective clinical study. Fifteen yearling (250 - 400 kg) horses during field castration. Horses were maintained in dorsal recumbency during anesthesia with an intravenous infusion of 2000 mg ketamine and 500 mg xylazine in 1 L of 5% guaifenesin. Arterial samples for blood gas analysis were collected immediately post-induction (PI), and at 15 and 30 minutes PI. The control group (n = 6) breathed ambient air. The treatment group (n = 9) were administered pulsed-flow oxygen (192 mL per bolus) by nasal insufflation during inspiration for 15 minutes PI, then breathed ambient air. The study was performed at 1300 m above sea level. One-way and two-way repeated-measures anova with post-hoc Bonferroni tests were used for within and between-group comparisons, respectively. Significance was set at p ≤ 0.05. Mean ± SD PaO2 in controls at 0, 15 and 30 minutes PI were 46 ± 7 mmHg (6.1 ± 0.9 kPa), 42 ± 9 mmHg (5.6 ± 1.1 kPa), and 48 ± 7 mmHg (6.4 ± 0.1 kPa), respectively (p = 0.4). In treatment animals, oxygen administration significantly increased PaO2 at 15 minutes PI to 60 ± 13 mmHg (8.0 ± 1.7 kPa), compared with baseline values of 46 ± 8 mmHg (6.1 ± 1 kPa) (p = 0.007), and 30 minute PI values of 48 ± 7 mmHg (6.5 ± 0.9 kPa) (p = 0.003). These data show that a pulsed-flow delivery of oxygen can increase PaO2 in dorsally recumbent horses during field anesthesia with ketamine-xylazine-guaifenesin. The portable oxygen concentrator may help combat hypoxemia during field anesthesia in horses. © 2015 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.
Uryash, Arkady; Wu, Heng; Bassuk, Jorge; Kurlansky, Paul; Sackner, Marvin A; Adams, Jose A
2009-06-01
Low-amplitude pulses to the vasculature increase pulsatile shear stress to the endothelium. This activates endothelial nitric oxide (NO) synthase (eNOS) to promote NO release and endothelial-dependent vasodilatation. Descent of the dicrotic notch on the arterial pulse waveform and a-to-b ratio (a/b; where a is the height of the pulse amplitude and b is the height of the dicrotic notch above the end-diastolic level) reflects vasodilator (increased a/b) and vasoconstrictor effects (decreased a/b) due to NO level change. Periodic acceleration (pG(z)) (motion of the supine body head to foot on a platform) provides systemic additional pulsatile shear stress. The purpose of this study was to determine whether or not pG(z) applied to rats produced endothelial-dependent vasodilatation and increased NO production, and whether the latter was regulated by the Akt/phosphatidylinositol 3-kinase (PI3K) pathway. Male rats were anesthetized and instrumented, and pG(z) was applied. Sodium nitroprusside, N(G)-nitro-l-arginine methyl ester (l-NAME), and wortmannin (WM; to block Akt/PI3K pathway) were administered to compare changes in a/b and mean aortic pressure. Descent of the dicrotic notch occurred within 2 s of initiating pG(z). Dose-dependent increase of a/b and decrease of mean aortic pressure took place with SNP. l-NAME produced a dose-dependent rise in mean aortic pressure and decrease of a/b, which was blunted with pG(z). In the presence of WM, pG(z) did not decrease aortic pressure or increase a/b. WM also abolished the pG(z) blunting effect on blood pressure and a/b of l-NAME-treated animals. eNOS expression was increased in aortic tissue after pG(z). This study indicates that addition of low-amplitude pulses to circulation through pG(z) produces endothelial-dependent vasodilatation due to increased NO in rats, which is mediated via activation of eNOS, in part, by the Akt/PI3K pathway.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Furukawa, Yuki; Graduate School of Science, Kyoto University, Kitashirakawa, Sakyo, Kyoto 606-8502; Advanced Research Center for Beam Science, Institute for Chemical Research, Kyoto University, Gokasho, Uji, Kyoto 611-0011
By pairing femtosecond laser pulses (duration ∼40 fs and central wavelength ∼810 nm) at an appropriate time interval, a laser-induced periodic surface structure (LIPSS) is formed with much less ablation than one formed with a single pulse. On a titanium plate, a pair of laser pulses with fluences of 70 and 140 mJ/cm{sup 2} and a rather large time interval (>10 ps) creates a LIPSS with an interspace of 600 nm, the same as that formed by a single pulse of 210 mJ/cm{sup 2}, while the double pulse ablates only 4 nm, a quarter of the ablation depth of a single pulse.
Predicting successful supraclavicular brachial plexus block using pulse oximeter perfusion index.
Abdelnasser, A; Abdelhamid, B; Elsonbaty, A; Hasanin, A; Rady, A
2017-08-01
Supraclavicular nerve block is a popular approach for anaesthesia for upper limb surgeries. Conventional methods for evaluation of block success are time consuming and need patient cooperation. The aim of this study was to evaluate whether the perfusion index (PI) can be used to predict and provide a cut-off value for ultrasound-guided supraclavicular nerve block success. The study included 77 patients undergoing elective orthopaedic procedures under ultrasound-guided supraclavicular nerve block. After local anaesthetic injection, sensory block success was assessed every 3 min by pinprick, and motor block success was assessed every 5 min by the ability to flex the elbow and the hand against resistance. The PI was recorded at baseline and at 10, 20, and 30 min after anaesthetic injection in both blocked and non-blocked limbs. The PI ratio was calculated as the PI after 10 min divided by the PI at the baseline. Receiver operating characteristic curves were constructed for the accuracy of the PI in detection of block success. The PI was higher in the blocked limb at all time points, and this was paralleled by a higher PI ratio compared with the unblocked limb. Both the PI and the PI ratio at 10 min after injection showed a sensitivity and specificity of 100% for block success at cut-off values of 3.3 and 1.4, respectively. The PI is a useful tool for evaluation of successful supraclavicular nerve block. A PI ratio of > 1.4 is a good predictor for block success. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com
Neurophysin biosynthesis in normal rats and in rats with hereditary diabetes insipidus.
Brownstein, M J; Gainer, H
1977-01-01
When [35S]cysteine was injected adjacent to the supraoptic nucleus (SON) in rats, it was rapidly incorporated into proteins in the SON. The [35S]cysteine-labeled proteins extracted from the SON were separated by isoelectric focusing on polyacrylamide gels. Twenty minutes after the injection of [35S]cysteine, two major labeled peaks (pI = 5.4 and 6.1) were found in the SON of normal rats; Brattleboro rats had only one major labeled peak (pI = 5.4). One hour after the injection, four major radioactive peaks were found in the SON of normal animals (pI = 5.1, 5.4, 5.6, and 6.1). Animals with diabetes insipidus had only two major labeled proteins (pI = 5.1 AND 5.4). Twenty-four hours after normal rats were injected with [35S]cysteine, all of the labeled peaks described above, except for the one with pI = 5.1, had decreased markedly in size and a small amount of labeled protein with pI about 4.8 was present in the SON. After 24 hr the posterior pituitary of normal animals contained two [35S]cysteine-labeled proteins with pI = 4.6 AND 4.8. The pituitaries of Brattleboro rats had only the pI = 4.6 labeled protein. These pulse-chase data, with data we have presented elsewhere, indicate that the vasopressin- and oxytocin-neurophysins are synthesized as parts of separate precursors (pI = 6.1 and 5.4, respectively). These precursors are converted into at least two intermediates (pI = 5.6 and 5.1) which, in turn, yield the vasopressin-neurophysin (pI = 4.8) and the oxytocin-neurophysin (pI = 4.6). PMID:269451
A method for fabricating a micro-structured surface of polyimide with open and closed pores
NASA Astrophysics Data System (ADS)
Ma, Yong-Won; Oh, Jae Yong; Ahn, Seokyoung; Shin, Bo Sung
2016-08-01
A new approach for fabricating open and closed porous structures based on laser processing is presented. Liquid polyimide (PI) was mixed with azodicarbonamide which is a chemical blowing agent (CBA), and the mixture was spin-coated and pre-cured in order to fabricate solid PI films. Porous PI was prepared by irradiating PI films mixed with azodicarbonamide. The PI film with azodicarbonamide was etched by using laser ablation, and the azodicarbonamide was decomposed due to the heat induced by the absorbed laser energy. At higher laser beam irradiation, more pores were fabricated due to the resulting increase in the CBA decomposition from 27 mJ/cm2 to 40 mJ/cm2 per single pulse. A fluence of about 50 mJ/cm2 resulted in fewer and larger open pores, which were formed by the coalescence of small pores. In contrast, a closed porous structure was fabricated at a fluence of less than 1 mJ/cm2 because PI was barely etched. The proposed method can be used to create open and closed porous structures selectively and is not limited to thermosetting polymers, but is also effective with thermoplastic polymers.
Toyota, S; Hirosawa, S; Aoki, N
1994-02-01
Alpha 2-plasmin inhibitor (alpha 2PI) deficiency Okinawa results from defective secretion of the inhibitor from the liver and appears to be a direct consequence of the deletion of Glu137 in the amino acid sequence of alpha 2PI. To examine the effects of replacing the amino acid occupying position 137 or deleting its neighboring amino acid on alpha 2PI secretion, we used oligonucleotide-directed mutagenesis of alpha 2PI cDNA to change the codon specifying Glu137 or delete a codon specifying its neighboring amino acid. The effects were determined by pulse-chase experiments and by enzyme-linked immunosorbent assay of media from transiently transfected COS-7 cells. Replacement of Glu137 with an amino acid other than Cys had little effect on alpha 2PI secretion. In contrast, deletion of an amino acid in a region spanning a sequence of less than 30 amino acids including positions 127 and 137 severely impaired the secretion. The results suggest that structural integrity of the region, rather than its component amino acids, is important for the intracellular transport and secretion of alpha 2PI.
Method of high precision interval measurement in pulse laser ranging system
NASA Astrophysics Data System (ADS)
Wang, Zhen; Lv, Xin-yuan; Mao, Jin-jin; Liu, Wei; Yang, Dong
2013-09-01
Laser ranging is suitable for laser system, for it has the advantage of high measuring precision, fast measuring speed,no cooperative targets and strong resistance to electromagnetic interference,the measuremen of laser ranging is the key paremeters affecting the performance of the whole system.The precision of the pulsed laser ranging system was decided by the precision of the time interval measurement, the principle structure of laser ranging system was introduced, and a method of high precision time interval measurement in pulse laser ranging system was established in this paper.Based on the analysis of the factors which affected the precision of range measure,the pulse rising edges discriminator was adopted to produce timing mark for the start-stop time discrimination,and the TDC-GP2 high precision interval measurement system based on TMS320F2812 DSP was designed to improve the measurement precision.Experimental results indicate that the time interval measurement method in this paper can obtain higher range accuracy. Compared with the traditional time interval measurement system,the method simplifies the system design and reduce the influence of bad weather conditions,furthermore,it satisfies the requirements of low costs and miniaturization.
Pulse pile-up identification and reconstruction for liquid scintillator based neutron detectors
NASA Astrophysics Data System (ADS)
Luo, X. L.; Modamio, V.; Nyberg, J.; Valiente-Dobón, J. J.; Nishada, Q.; de Angelis, G.; Agramunt, J.; Egea, F. J.; Erduran, M. N.; Ertürk, S.; de France, G.; Gadea, A.; González, V.; Goasduff, A.; Hüyük, T.; Jaworski, G.; Moszyński, M.; Di Nitto, A.; Palacz, M.; Söderström, P.-A.; Sanchis, E.; Triossi, A.; Wadsworth, R.
2018-07-01
The issue of pulse pile-up is frequently encountered in nuclear experiments involving high counting rates, which will distort the pulse shapes and the energy spectra. A digital method of off-line processing of pile-up pulses is presented. The pile-up pulses were firstly identified by detecting the downward-going zero-crossings in the first-order derivative of the original signal, and then the constituent pulses were reconstructed based on comparing the pile-up pulse with four models that are generated by combining pairs of neutron and γ standard pulses together with a controllable time interval. The accuracy of this method in resolving the pile-up events was investigated as a function of the time interval between two pulses constituting a pile-up event. The obtained results show that the method is capable of disentangling two pulses with a time interval among them down to 20 ns, as well as classifying them as neutrons or γ rays. Furthermore, the error of reconstructing pile-up pulses could be kept below 6% when successive peaks were separated by more than 50 ns. By applying the method in a high counting rate of pile-up events measurement of the NEutron Detector Array (NEDA), it was empirically found that this method can reconstruct the pile-up pulses and perform neutron- γ discrimination quite accurately. It can also significantly correct the distorted pulse height spectrum due to pile-up events.
Forget, N; Canova, L; Chen, X; Jullien, A; Lopez-Martens, R
2009-12-01
We demonstrate arbitrary carrier-envelope (CE) phase control of femtosecond laser pulses by an acousto-optic programmable dispersive filter (AOPDF), with an accuracy better than pi/100 at a repetition rate of 1 kHz. We also demonstrate, for the first time to the best of our knowledge, 15 Hz closed-loop CE phase stabilization using an AOPDF inside a 1 kHz chirped pulse amplifier to correct for slow CE phase drifts.
Characterizing the graded structure of false killer whale (Pseudorca crassidens) vocalizations.
Murray, S O; Mercado, E; Roitblat, H L
1998-09-01
The vocalizations from two, captive false killer whales (Pseudorca crassidens) were analyzed. The structure of the vocalizations was best modeled as lying along a continuum with trains of discrete, exponentially damped sinusoidal pulses at one end and continuous sinusoidal signals at the other end. Pulse trains were graded as a function of the interval between pulses where the minimum interval between pulses could be zero milliseconds. The transition from a pulse train with no inter-pulse interval to a whistle could be modeled by gradations in the degree of damping. There were many examples of vocalizations that were gradually modulated from pulse trains to whistles. There were also vocalizations that showed rapid shifts in signal type--for example, switching immediately from a whistle to a pulse train. These data have implications when considering both the possible function(s) of the vocalizations and the potential sound production mechanism(s). A short-time duty cycle measure was developed to characterize the graded structure of the vocalizations. A random sample of 500 vocalizations was characterized by combining the duty cycle measure with peak frequency measurements. The analysis method proved to be an effective metric for describing the graded structure of false killer whale vocalizations.
NASA Technical Reports Server (NTRS)
Lund, G. F.; Westbrook, R. M.; Fryer, T. B.; Miranda, R. F.
1979-01-01
The system includes an implantable transmitter, external receiver-retransmitter collar, and a microprocessor-controlled demodulator. The size of the implant is suitable for animals with body weights of a few kilograms or more; further size reduction of the implant is possible. The ECG is sensed by electrodes designed for internal telemetry and to reduce movement artifacts. The R-wave characteristics are then specifically selected to trigger a short radio frequency pulse. Temperatures are sensed at desired locations by thermistors and then, based on a heartbeat counter, transmitted intermittently via pulse interval modulation. This modulation scheme includes first and last calibration intervals for a reference by ratios with the temperature intervals to achieve good accuracy even over long periods. Pulse duration and pulse sequencing are used to discriminate between heart rate and temperature pulses as well as RF interference.
Coherent control of ultrafast optical four-wave mixing with two-color {omega}-3{omega} laser pulses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Serrat, Carles
2005-08-15
A theoretical investigation on the coherent control of optical transient four-wave mixing interactions in two-level systems with two intense few-cycle propagating laser pulses of central angular frequencies {omega} and 3{omega} is reported. By numerically solving the full Maxwell-Bloch equations beyond the slowly varying envelope and rotating-wave approximations in the time domain, the nonlinear coupling to the optical field at frequency 5{omega} is found to depend critically on the initial relative phase {phi} of the propagating pulses: the coupling is enhanced when the pulses interfere constructively in the center ({phi}=0), while it is nearly suppressed when they are out of phasemore » ({phi}={pi})« less
Heilmann, R M; Grützner, N; Hokamp, J A; Lidbury, J A; Xenoulis, P G; Suchodolski, J S; Nabity, M B; Cianciolo, R; Steiner, J M
2018-06-01
Serum canine α 1 -proteinase inhibitor (cα 1 -PI) concentrations were evaluated in dogs with pancreatitis (n=24), exocrine pancreatic insufficiency (EPI; n=29), chronic hepatitis (CH; n=11) or proteinuric chronic kidney disease (CKD-P; n=61) to determine whether systemic proteinase/proteinase-inhibitor balance is altered in these conditions. Dogs with CKD-P had significantly lower cα 1 -PI concentrations than dogs with pancreatitis, EPI or CH; 16% of dogs with CKD-P had serum cα 1 -PI concentrations below the reference interval. Serum and urine cα 1 -PI concentrations were inversely correlated in dogs with CKD-P, but not in dogs with CH. This suggests that renal loss of cα 1 -PI contributes to decreased serum concentrations in dogs with CKD-P, while hepatic cα 1 -PI synthesis with CH either is not compromised or is counterbalanced by extrahepatic production. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Zheltikov, A. M.
2002-08-01
A harmonic oscillator model is used to demonstrate the possibility of coherent control of acoustic vibrations of metal nanoparticles and thin films with sequences of femtosecond laser pulses. When the interval between the pulses in such a sequence is chosen equal to the oscillation period of the expansion mode of a nanoscale system, the relevant acoustic vibrations can be excited in a resonant and selective way. Sequences of femtosecond pulses with picosecond time intervals between the pulses are shown to be ideally suited for a resonant excitation and coherent control of acoustic modes of silver nanoparticles.
Effect of Ca/sup 2 +/ overload on phosphoinositide (PI) metabolism in cardiac muscle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Otani, H.; Otani, H.; Engelman, R.M.
1986-05-01
The investigated the relationship between Ca/sup 2 +/ load and PI metabolism in isolated rat papillary muscle labeled with (/sup 3/H)inositol. Increase in (Ca/sup 2 +/)/sub o/ from 0-3.6 mM reduced the incorporation of (/sup 3/H) inositol into PI moderately and increased the resting tension slightly. The incorporation of the label into PI was unchanged by 10 ..mu..m A-23187 at 1.8 mM (Ca/sup 2 +/)/sub o/ that increased the contractility by 70% without a significant change in the resting tension. However, either 10.8 mM (Ca/sup 2 +/)/sub o/ or 0.3 mM ouabain at 1.8 mM (Ca/sup 2 +/)/sub o/ markedlymore » decreased the PI labeling with corresponding increase in the resting tension while inclusion of excess EGTA greatly enhanced the radioactivity in PI. Determination of the PI breakdown and the inositol phosphates production by pulse-chase experiments revealed that the reduced PI turnover in the Ca/sup 2 +/-overload muscle was due to both inhibition of the synthesis and stimulation of the breakdown of this lipid that accounted for 30% decrease in the labeled PI from the muscle during 45 min without significant loss of the net PI pool size, suggesting the presence of a relatively smaller compartment of PI pool undergoing a rapid breakdown during Ca/sup 2 +/ overload. The authors propose that alteration of Ca/sup 2 +/ homeostasis may modulate the production of putative second messengers, inositol trisphosphate and diacylglycerol, which feed back to regulate (Ca/sup 2 +/)/sub i/ in cardiac muscle.« less
Control of photon storage time using phase locking.
Ham, Byoung S
2010-01-18
A photon echo storage-time extension protocol is presented by using a phase locking method in a three-level backward propagation scheme, where phase locking serves as a conditional stopper of the rephasing process in conventional two-pulse photon echoes. The backward propagation scheme solves the critical problems of extremely low retrieval efficiency and pi rephasing pulse-caused spontaneous emission noise in photon echo based quantum memories. The physics of the storage time extension lies in the imminent population transfer from the excited state to an auxiliary spin state by a phase locking control pulse. We numerically demonstrate that the storage time is lengthened by spin dephasing time.
Observation of high-order quantum resonances in the kicked rotor.
Kanem, J F; Maneshi, S; Partlow, M; Spanner, M; Steinberg, A M
2007-02-23
Quantum resonances in the kicked rotor are characterized by a dramatically increased energy absorption rate, in stark contrast to the momentum localization generally observed. These resonances occur when the scaled Planck's constant Planck's [over ]=r/s 4pi, for any integers r and s. However, only the variant Planck's [over ]=r2pi resonances are easily observable. We have observed high-order quantum resonances (s>2) utilizing a sample of low energy, noncondensed atoms and a pulsed optical standing wave. Resonances are observed for variant Planck's [over ]=r/16 4pi for integers r=2-6. Quantum numerical simulations suggest that our observation of high-order resonances indicate a larger coherence length (i.e., coherence between different wells) than expected from an initially thermal atomic sample.
2010-05-11
UNCLASSIFIED 11 Occupant Model Inputs: Blast Pulse (apeak) Seat Cushion Foam Stiffness (sc) Seat EA System Stiffness (sEA) Outputs: Upper Neck Axial Force...Floor Pad Surrogate model from linear regression on 300 data points: Inputs: Blast Pulse (apeak) Seat Cushion Foam Stiffness (sc) Seat EA System...B Ground Vehicle Weight and Occupant Safety Under Blast Loading Steven Hoffenson, presenter (U of M) Panos Papalambros, PI (U of M) Michael
1993-01-01
C-R248 Phone: (619) 455-9741 PI: DAVID ANDING Title: Method for Incorporating High -Fidelity Engineering Models Into Distributed Simulations Abstract...Ferroelectric Capacitors for Pulse Power Electronics Abstract: High -density energy storage and fast discharge will be critical in a variety of high ...to meet the design objectives of High Energy Density Capacitors (HEDC) for energy storage in pulsed power systems (15 to 45 mJ/kg). In the proposed
Demodulator for binary-phase modulated signals having a variable clock rate
NASA Technical Reports Server (NTRS)
Wu, Ta Tzu (Inventor)
1976-01-01
Method and apparatus for demodulating binary-phase modulated signals recorded on a magnetic stripe on a card as the card is manually inserted into a card reader. Magnetic transitions are sensed as the card is read and the time interval between immediately preceeding basic transitions determines the duration of a data sampling pulse which detects the presence or absence of an intermediate transition pulse indicative of two respective logic states. The duration of the data sampling pulse is approximately 75 percent of the preceeding interval between basic transitions to permit tracking succeeding time differences in basic transition intervals of up to approximately 25 percent.
Chirped femtosecond pulse scattering by spherical particles
NASA Astrophysics Data System (ADS)
Kim, Dal-Woo; Xiao, Gang-Yao; Lee, Tong-Nyong
1996-05-01
Generalized Lorentz-Mie formulas are used to study the scattering characteristics when a chirped femtosecond pulse illuminates a spherical particle. For a linear chirped Gaussian pulse with the envelope function g( tau ) = exp[- pi (1 + ib) tau 2], dimensionless parameter b is defined as a chirp. The calculation illustrated that even for pulses with a constant carrier wavelength ( lambda 0 = 0.5 mu m) and pulse-filling coefficient (l0 = 1.98), the efficiencies for extinction and scattering differ very much between the carrier wave and the different chirped pulses. The slowly varying background of the extinction and the scattering curves is damped by the chirp. When the pulse is deeply chirped, the maxima and minima of the background curves reduce to the point where they disappear, and the efficiency curves illustrate a steplike dependence on the sphere size. Another feature is that the only on the amount of chirp (|b|), regardless of upchirp (b greater than 0) or downchirp (b less than 0).
Brar, I; Robertson, A D; Hughson, R L
2016-05-01
South Asians (SA) suffer from a higher burden of heart disease and stroke compared with White Caucasians (CA). We hypothesized that increased arterial stiffness in older adults of SA origin would be associated with greater cerebrovascular pulsatile pressure and flow characteristics compared with CA older adults. Forty-four SA and CA older adults, free of known cardiovascular and cerebrovascular diseases, were assessed. Vascular ageing was characterized by brachial-ankle pulse wave velocity, carotid pulse pressure, compliance coefficient (CC) and intima-media thickness (IMT). Duplex ultrasonography of the internal carotid arteries estimated anterior cerebral blood flow (aCBF) and cerebrovascular resistance (aCVR), and transcranial Doppler ultrasound quantified middle cerebral artery blood flow velocity, resistive index (RI) and pulsatility index (PI). Fasting blood samples were collected to assess glycaemic status, lipid profile and C-reactive protein. SA had higher carotid pulse pressure and lower CC indicating stiffer arteries compared with CA. Multiple regression analyses revealed that ethnic differences in arterial stiffness were associated with glycated haemoglobin level in SA. Among SA, an inverse association was observed between carotid CC and aCVR. In turn, aCVR was associated with a steeper reduction in aCBF in SA than in CA. IMT was strongly associated with greater PI and RI (r>0.81, P<0.001) in SA, whereas a weaker relationship for PI (r=0.46, P=0.03) and no significant relationship for RI were found in CA. The study found stronger associations between pulsatile cerebrovascular haemodynamics and structural and functional alterations in central arteries in SA that may underlie the elevated risk for cerebrovascular disease.
High aspect ratio nanoholes in glass generated by femtosecond laser pulses with picosecond intervals
NASA Astrophysics Data System (ADS)
Ahn, Sanghoon; Choi, Jiyeon; Noh, Jiwhan; Cho, Sung-Hak
2018-02-01
Because of its potential uses, high aspect ratio nanostructures have been interested for last few decades. In order to generate nanostructures, various techniques have been attempted. Femtosecond laser ablation is one of techniques for generating nanostructures inside a transparent material. For generating nanostructures by femtosecond laser ablation, previous studies have been attempted beam shaping such as Bessel beam and temporal tailored beam. Both methods suppress electron excitation at near surface and initiate interference of photons at certain depth. Recent researches indicate that shape of nanostructures is related with temporal change of electron density and number of self-trapped excitons. In this study, we try to use the temporal change of electron density induced by femtosecond laser pulse for generating high aspect ratio nanoholes. In order to reveal the effect of temporal change of electron density, secondary pulses are irradiated from 100 to 1000 ps after the irradiation of first pulse. Our result shows that diameter of nanoholes is increasing and depth of nanoholes is decreasing as pulse to pulse interval is getting longer. With manipulating of pulse to pulse interval, we could generate high aspect ratio nanoholes with diameter of 250-350 nm and depth of 4∼6 μm inside a glass.
Becari, Christiane; Durand, Marina T.; Guimaraes, Alessander O.; Lataro, Renata M.; Prado, Cibele M.; de Oliveira, Mauro; Candido, Sarai C. O.; Pais, Paloma; Ribeiro, Mauricio S.; Bader, Michael; Pesquero, Joao B.; Salgado, Maria C. O.; Salgado, Helio C.
2017-01-01
In vitro and ex vivo experiments indicate that elastase-2 (ELA-2), a chymotrypsin-serine protease elastase family member 2A, is an alternative pathway for angiotensin II (Ang II) generation. However, the role played by ELA-2 in vivo is unclear. We examined ELA-2 knockout (ELA-2KO) mice compared to wild-type (WT) mice and determined whether ELA-2 played a role in hemodynamics [arterial pressure (AP) and heart rate (HR)], cardiocirculatory sympathovagal balance and baroreflex sensitivity. The variability of systolic arterial pressure (SAP) and pulse interval (PI) for evaluating autonomic modulation was examined for time and frequency domains (spectral analysis), whereas a symbolic analysis was also used to evaluate PI variability. In addition, baroreflex sensitivity was examined using the sequence method. Cardiac function was evaluated echocardiographically under anesthesia. The AP was normal whereas the HR was reduced in ELA-2KO mice (425 ± 17 vs. 512 ± 13 bpm from WT). SAP variability and baroreflex sensitivity were similar in both strains. The LF power from the PI spectrum (33.6 ± 5 vs. 51.8 ± 4.8 nu from WT) and the LF/HF ratio (0.60 ± 0.1 vs. 1.45 ± 0.3 from WT) were reduced, whereas the HF power was increased (66.4 ± 5 vs. 48.2 ± 4.8 nu from WT) in ELA-2KO mice, indicating a shift toward parasympathetic modulation of HR. Echocardiographic examination showed normal fractional shortening and an ejection fraction in ELA-2KO mice; however, the cardiac output, stroke volume, and ventricular size were reduced. These findings provide the first evidence that ELA-2 acts on the sympathovagal balance of the heart, as expressed by the reduced sympathetic modulation of HR in ELA-2KO mice. PMID:28386233
Becari, Christiane; Durand, Marina T; Guimaraes, Alessander O; Lataro, Renata M; Prado, Cibele M; de Oliveira, Mauro; Candido, Sarai C O; Pais, Paloma; Ribeiro, Mauricio S; Bader, Michael; Pesquero, Joao B; Salgado, Maria C O; Salgado, Helio C
2017-01-01
In vitro and ex vivo experiments indicate that elastase-2 (ELA-2), a chymotrypsin-serine protease elastase family member 2A, is an alternative pathway for angiotensin II (Ang II) generation. However, the role played by ELA-2 in vivo is unclear. We examined ELA-2 knockout (ELA-2KO) mice compared to wild-type (WT) mice and determined whether ELA-2 played a role in hemodynamics [arterial pressure (AP) and heart rate (HR)], cardiocirculatory sympathovagal balance and baroreflex sensitivity. The variability of systolic arterial pressure (SAP) and pulse interval (PI) for evaluating autonomic modulation was examined for time and frequency domains (spectral analysis), whereas a symbolic analysis was also used to evaluate PI variability. In addition, baroreflex sensitivity was examined using the sequence method. Cardiac function was evaluated echocardiographically under anesthesia. The AP was normal whereas the HR was reduced in ELA-2KO mice (425 ± 17 vs. 512 ± 13 bpm from WT). SAP variability and baroreflex sensitivity were similar in both strains. The LF power from the PI spectrum (33.6 ± 5 vs. 51.8 ± 4.8 nu from WT) and the LF/HF ratio (0.60 ± 0.1 vs. 1.45 ± 0.3 from WT) were reduced, whereas the HF power was increased (66.4 ± 5 vs. 48.2 ± 4.8 nu from WT) in ELA-2KO mice, indicating a shift toward parasympathetic modulation of HR. Echocardiographic examination showed normal fractional shortening and an ejection fraction in ELA-2KO mice; however, the cardiac output, stroke volume, and ventricular size were reduced. These findings provide the first evidence that ELA-2 acts on the sympathovagal balance of the heart, as expressed by the reduced sympathetic modulation of HR in ELA-2KO mice.
NASA Astrophysics Data System (ADS)
Vintzentz, S. V.; Sandomirsky, V. B.
1992-09-01
An extension of the photothermal surface deformation (PTSD) method to study the macroscopic kinetics of the first-order phase transition (PTr) is given. The movement of the phase interface (PI) over a surface with a PTr locally induced in the subsurface volume by a focused laser pulse is investigated for the first time using radial measurements of the PTSD kinetics. For the known metal-to-semiconductor PTr in VO 2 (a good model system) a procedure is suggested for measuring the maximum size rsm of the "hot" (metal) phase on the surface (a parameter most difficult to determine) as well as for estimating the velocity of the PI movement over the surface, vs, and in the bulk, vb. Besides, it is shown that the PTSD method may be used to determine the "local" threshold energy E0 needed for the laser-induced PTr and the "local" latent heat L of the PTr. This demonstrates the feasibility of scanning surface E0- and L-microscopy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sakka, Tetsuo; Institute of Sustainability Science, Kyoto University, Uji, Kyoto 611-0011; Tamura, Ayaka
2012-05-07
We experimentally study the dynamics of the plasma induced by the double-laser-pulse irradiation of solid target in water, and find that an appropriate choice of the pulse energies and pulse interval results in the production of an unprecedentedly mild (low-density) plasma, the emission spectra of which are very narrow even without the time-gated detection. The optimum pulse interval and pulse energies are 15-30 {mu}s and about {approx}1 mJ, respectively, where the latter values are much smaller than those typically employed for this kind of study. In order to clarify the mechanism for the formation of mild plasma we examine themore » role of the first and second laser pulses, and find that the first pulse produces the cavitation bubble without emission (and hence plasma), and the second pulse induces the mild plasma in the cavitation bubble. These findings may present a new phase of underwater laser-induced breakdown spectroscopy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tamura, Ayaka, E-mail: tamura.ayaka.88m@st.kyoto-u.ac.jp; Matsumoto, Ayumu; Nishi, Naoya
We investigate the effects of temporal laser profile on the emission spectra of laser ablation plasma in water. We use short-interval (76 ns) double pulses with different pulse durations of the composing two pulses for the irradiation of underwater target. Narrow atomic spectral lines in emission spectra are obtained by the irradiation, where the two pulses are wide enough to be merged into a single-pulse-like temporal profile, while deformed spectra are obtained when the two pulses are fully separated. The behavior of the atomic spectral lines for the different pulse durations is consistent with that of the temporal profiles of themore » optical emission intensities of the plasma. All these results suggest that continuous excitation of the plasma during the laser irradiation for ∼100 ns is a key to obtain narrow emission spectral lines.« less
[Estimation of the atrioventricular time interval by pulse Doppler in the normal fetal heart].
Hamela-Olkowska, Anita; Dangel, Joanna
2009-08-01
To assess normative values of the fetal atrioventricular (AV) time interval by pulse-wave Doppler methods on 5-chamber view. Fetal echocardiography exams were performed using Acuson Sequoia 512 in 140 singleton fetuses at 18 to 40 weeks of gestation with sinus rhythm and normal cardiac and extracardiac anatomy. Pulsed Doppler derived AV intervals were measured from left ventricular inflow/outflow view using transabdominal convex 3.5-6 MHz probe. The values of AV time interval ranged from 100 to 150 ms (mean 123 +/- 11.2). The AV interval was negatively correlated with the heart rhythm (p<0.001). Fetal heart rate decreased as gestation progressed (p<0.001). Thus, the AV intervals increased with the age of gestation (p=0.007). However, in the same subgroup of the fetal heart rate there was no relation between AV intervals and gestational age. Therefore, the AV intervals showed only the heart rate dependence. The 95th percentiles of AV intervals according to FHR ranged from 135 to 148 ms. 1. The AV interval duration was negatively correlated with the heart rhythm. 2. Measurement of AV time interval is easy to perform and has a good reproducibility. It may be used for the fetal heart block screening in anti-Ro and anti-La positive pregnancies. 3. Normative values established in the study may help obstetricians in assessing fetal abnormalities of the AV conduction.
NASA Astrophysics Data System (ADS)
Li, Songhai; Wang, Kexiong; Wang, Ding; Akamatsu, Tomonari
2005-12-01
The signals of dolphins and porpoises often exhibit a multi-pulse structure. Here, echolocation signal recordings were made from four geometrically distinct positions of seven Yangtze finless porpoises temporarily housed in a relatively small, enclosed area. Some clicks demonstrated double-pulse, and others multi-pulse, structure. The interpulse intervals between the first and second pulse of the double- and multi-pulse clicks were significantly different among data from the four different positions (p<0.01, one-way ANOVA). These results indicate that the interpulse interval and structure of the double- and multi-pulse echolocation signals depend on the hydrophone geometry of the animal, and that the double- and multi-pulse structure of echolocation signals in Yangtze finless porpoise is not caused by the phonating porpoise itself, but by the multipath propagation of the signal. Time delays in the 180° phase-shifted surface reflection pulse and the nonphase-shifted bottom reflection pulse of the multi-pulse structures, relative to the direct signal, can be used to calculate the distance to a phonating animal.
NASA Technical Reports Server (NTRS)
Rhim, W. K.; Dart, J. A.
1982-01-01
New pulse generator programmed to produce pulses from several ports at different pulse lengths and intervals and virtually any combination and sequence. Unit contains a 256-word-by-16-bit memory loaded with instructions either manually or by computer. Once loaded, unit operates independently of computer.
NASA Astrophysics Data System (ADS)
Yang, Feng-Yi; Chiu, Wei-Hsiu; Yeh, Chi-Fang
2011-09-01
The objective of current study was to investigate the functional changes in arteries induced by pulsed-HIFU with or without microbubbles. Sonication was applied at an ultrasound frequency of 1 MHz with a burst length of 50 ms and a repetition frequency of 1 Hz. The duration of the whole sonication was 6s. The abdominal aortas of Sprague-Dawley rats were surgically exposed and sonicated with pulsed HIFU; the pulsed HIFU beam was aimed using color images of the blood flow. There was no obvious normalized peak systolic velocity (PSV) change at various acoustic powers of pulsed-HIFU exposure in the absence of ultrasound contrast agent (UCA). However, the normalized PSV change induced by pulsed-HIFU decreased with the injected dose of UCA at acoustic powers. At this time, the normalized pulsatility index (PI) change in the vessel subjected to pulsed-HIFU increased in proportion to UCA dose. Additional research is needed to investigate the detailed mechanical effects of pulsed-HIFU exposure on blood flow and the structure of vessel walls.
NASA Astrophysics Data System (ADS)
Shen, Xuan; Xia, Xiaohong; Du, Yongling; Wang, Chunming
2017-09-01
An electrochemical sensor for determination of hydroquinone (HQ) and catechol (CC) was developed using Au nanoparticles (AuNPs) fabricated on reduced graphene oxide/polyimide (PI/RGO) film by electroless deposition. The electrochemical behaviors of HQ and CC at PI/RGO-AuNPs electrode were investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Under the optimized condition, the current responses at PI/RGO-AuNPs electrode were linear over ranges from 1 to 654 mol/L for HQ and from 2 to 1289 mol/L for CC, with the detection limits of 0.09 and 0.2 mol/L, respectively. The proposed electrode exhibited good reproducibility, stability and selectivity. In addition, the proposed electrode was successfully applied in the determination of HQ and CC in tap water and the Yellow River samples.
NASA Astrophysics Data System (ADS)
Ma, Yong-Won; Jeong, Myung Yung; Lee, Sang-Mae; Shin, Bo Sung
2016-03-01
A new approach for fabricating a high-density nano-porous structure on polyimide (PI) by using a 355-nm UV laser is presented here. When PI was irradiated by using a laser, debris that had electrical conductivity was generated. Accordingly, that debris caused electrical defects in the field of electronics. Thus, many researchers have tried to focus on a clean processing without debris. However, this study focused on forming a high density of debris so as to fabricate a nano-porous structure consisting of nanofibers on the PI film. A PI film with closed pores and open pores was successfully formed by using a chemical blowing agent (azodicarbonamide, CBA) in an oven. Samples were precured at 130 °C and cured at 205 °C in sequence so that the closed pores might not coalesce in the film. When the laser irradiated the PI film with closed pores, nanofibers were generated because polyimide was not completely decomposed by photochemical ablation. Our results indicated that a film with micro-closed pores, in conjunction with a 355-nm pulsed laser, can facilitate the fabrication of a high-density nano-porous structure.
Fiedler, Tomas; Mix, Maren; Meyer, Uta; Mikkat, Stefan; Glocker, Michael O.; Bahl, Hubert; Fischer, Ralf-Jörg
2008-01-01
The phoPR gene locus of Clostridium acetobutylicum ATCC 824 comprises two genes, phoP and phoR. Deduced proteins are predicted to represent a response regulator and sensor kinase of a phosphate-dependent two-component regulatory system. We analyzed the expression patterns of phoPR in Pi-limited chemostat cultures and in response to Pi pulses. A basic transcription level under high-phosphate conditions was shown, and a significant increase in mRNA transcript levels was found when external Pi concentrations dropped below 0.3 mM. In two-dimensional gel electrophoresis experiments, a 2.5-fold increase in PhoP was observed under Pi-limiting growth conditions compared to growth with an excess of Pi. At least three different transcription start points for phoP were determined by primer extension analyses. Proteins PhoP and an N-terminally truncated *PhoR were individually expressed heterologously in Escherichia coli and purified. Autophosphorylation of *PhoR and phosphorylation of PhoP were shown in vitro. Electromobility shift assays proved that there was a specific binding of PhoP to the promoter region of the phosphate-regulated pst operon of C. acetobutylicum. PMID:18689481
Greer, Matthew D; Shih, Joanna H; Lay, Nathan; Barrett, Tristan; Kayat Bittencourt, Leonardo; Borofsky, Samuel; Kabakus, Ismail M; Law, Yan Mee; Marko, Jamie; Shebel, Haytham; Mertan, Francesca V; Merino, Maria J; Wood, Bradford J; Pinto, Peter A; Summers, Ronald M; Choyke, Peter L; Turkbey, Baris
2017-12-01
Purpose To validate the dominant pulse sequence paradigm and limited role of dynamic contrast material-enhanced magnetic resonance (MR) imaging in the Prostate Imaging Reporting and Data System (PI-RADS) version 2 for prostate multiparametric MR imaging by using data from a multireader study. Materials and Methods This HIPAA-compliant retrospective interpretation of prospectively acquired data was approved by the local ethics committee. Patients were treatment-naïve with endorectal coil 3-T multiparametric MR imaging. A total of 163 patients were evaluated, 110 with prostatectomy after multiparametric MR imaging and 53 with negative multiparametric MR imaging and systematic biopsy findings. Nine radiologists participated in this study and interpreted images in 58 patients, on average (range, 56-60 patients). Lesions were detected with PI-RADS version 2 and were compared with whole-mount prostatectomy findings. Probability of cancer detection for overall, T2-weighted, and diffusion-weighted (DW) imaging PI-RADS scores was calculated in the peripheral zone (PZ) and transition zone (TZ) by using generalized estimating equations. To determine dominant pulse sequence and benefit of dynamic contrast-enhanced (DCE) imaging, odds ratios (ORs) were calculated as the ratio of odds of cancer of two consecutive scores by logistic regression. Results A total of 654 lesions (420 in the PZ) were detected. The probability of cancer detection for PI-RADS category 2, 3, 4, and 5 lesions was 15.7%, 33.1%, 70.5%, and 90.7%, respectively. DW imaging outperformed T2-weighted imaging in the PZ (OR, 3.49 vs 2.45; P = .008). T2-weighted imaging performed better but did not clearly outperform DW imaging in the TZ (OR, 4.79 vs 3.77; P = .494). Lesions classified as PI-RADS category 3 at DW MR imaging and as positive at DCE imaging in the PZ showed a higher probability of cancer detection than did DCE-negative PI-RADS category 3 lesions (67.8% vs 40.0%, P = .02). The addition of DCE imaging to DW imaging in the PZ was beneficial (OR, 2.0; P = .027), with an increase in the probability of cancer detection of 15.7%, 16.0%, and 9.2% for PI-RADS category 2, 3, and 4 lesions, respectively. Conclusion DW imaging outperforms T2-weighted imaging in the PZ; T2-weighted imaging did not show a significant difference when compared with DW imaging in the TZ by PI-RADS version 2 criteria. The addition of DCE imaging to DW imaging scores in the PZ yields meaningful improvements in probability of cancer detection. © RSNA, 2017 An earlier incorrect version of this article appeared online. This article was corrected on July 27, 2017. Online supplemental material is available for this article.
Synchronous Seasonal Change in Fin Whale Song in the North Pacific
Oleson, Erin M.; Širović, Ana; Bayless, Alexandra R.; Hildebrand, John A.
2014-01-01
Fin whale (Balaenoptera physalus) song consists of down-swept pulses arranged into stereotypic sequences that can be characterized according to the interval between successive pulses. As in blue (B. musculus) and humpback whales (Megaptera novaeangliae), these song sequences may be geographically distinct and may correlate with population boundaries in some regions. We measured inter-pulse intervals of fin whale songs within year-round acoustic datasets collected between 2000 and 2006 in three regions of the eastern North Pacific: Southern California, the Bering Sea, and Hawaii. A distinctive song type that was recorded in all three regions is characterized by singlet and doublet inter-pulse intervals that increase seasonally, then annually reset to the same shorter intervals at the beginning of each season. This song type was recorded in the Bering Sea and off Southern California from September through May and off Hawaii from December through April, with the song interval generally synchronized across all monitoring locations. The broad geographic and seasonal occurrence of this particular fin whale song type may represent a single population broadly distributed throughout the eastern Pacific with no clear seasonal migratory pattern. Previous studies attempting to infer population structure of fin whales in the North Pacific using synchronous individual song samples have been unsuccessful, likely because they did not account for the seasonal lengthening in song intervals observed here. PMID:25521493
Synchronous seasonal change in fin whale song in the North Pacific.
Oleson, Erin M; Širović, Ana; Bayless, Alexandra R; Hildebrand, John A
2014-01-01
Fin whale (Balaenoptera physalus) song consists of down-swept pulses arranged into stereotypic sequences that can be characterized according to the interval between successive pulses. As in blue (B. musculus) and humpback whales (Megaptera novaeangliae), these song sequences may be geographically distinct and may correlate with population boundaries in some regions. We measured inter-pulse intervals of fin whale songs within year-round acoustic datasets collected between 2000 and 2006 in three regions of the eastern North Pacific: Southern California, the Bering Sea, and Hawaii. A distinctive song type that was recorded in all three regions is characterized by singlet and doublet inter-pulse intervals that increase seasonally, then annually reset to the same shorter intervals at the beginning of each season. This song type was recorded in the Bering Sea and off Southern California from September through May and off Hawaii from December through April, with the song interval generally synchronized across all monitoring locations. The broad geographic and seasonal occurrence of this particular fin whale song type may represent a single population broadly distributed throughout the eastern Pacific with no clear seasonal migratory pattern. Previous studies attempting to infer population structure of fin whales in the North Pacific using synchronous individual song samples have been unsuccessful, likely because they did not account for the seasonal lengthening in song intervals observed here.
Delvendahl, Igor; Lindemann, Hannes; Jung, Nikolai H; Pechmann, Astrid; Siebner, Hartwig R; Mall, Volker
2014-01-01
Transcranial magnetic stimulation (TMS) of the human primary motor hand area (M1-HAND) can produce multiple descending volleys in fast-conducting corticospinal neurons, especially so-called indirect waves (I-waves) resulting from trans-synaptic excitation. Facilitatory interaction between these I-waves can be studied non-invasively using a paired-pulse paradigm referred to as short-interval intracortical facilitation (SICF). We examined whether SICF depends on waveform and current direction of the TMS pulses. In young healthy volunteers, we applied single- and paired-pulse TMS to M1-HAND. We probed SICF by pairs of monophasic or half-sine pulses at suprathreshold stimulation intensity and inter-stimulus intervals (ISIs) between 1.0 and 5.0 ms. For monophasic paired-pulse stimulation, both pulses had either a posterior-anterior (PA) or anterior-posterior (AP) current direction (AP-AP or PA-PA), whereas current direction was reversed between first and second pulse for half-sine paired-pulse stimulation (PA-AP and AP-PA). Monophasic AP-AP stimulation resulted in stronger early SICF at 1.4 ms relative to late SICF at 2.8 and 4.4 ms, whereas monophasic PA-PA stimulation produced SICF of comparable size at all three peaks. With half-sine stimulation the third SICF peak was reduced for PA-AP current orientation compared with AP-PA. SICF elicited using monophasic as well as half-sine pulses is affected by current direction at clearly suprathreshold intensities. The impact of current orientation is stronger for monophasic compared with half-sine pulses. The direction-specific effect of paired-pulse TMS on the strength of early versus late SICF shows that different cortical circuits mediate early and late SICF. Copyright © 2014 Elsevier Inc. All rights reserved.
Mbye, Lamin H; Keles, Eyup; Tao, Luyang; Zhang, Jimmy; Chung, Joonyong; Larvie, Mykol; Koppula, Rajani; Lo, Eng H; Whalen, Michael J
2012-03-01
Loss of plasma membrane integrity is a feature of acute cellular injury/death in vitro and in vivo. Plasmalemma-resealing agents are protective in acute central nervous system injury models, but their ability to reseal cell membranes in vivo has not been reported. Using a mouse controlled cortical impact (CCI) model, we found that propidium iodide-positive (PI+) cells pulse labeled at 6, 24, or 48 hours maintained a degenerative phenotype and disappeared from the injured brain by 7 days, suggesting that plasmalemma permeability is a biomarker of fatal cellular injury after CCI. Intravenous or intracerebroventricular administration of Kollidon VA64, poloxamer P188, or polyethylene glycol 8000 resealed injured cell membranes in vivo (P<0.05 versus vehicle or poloxamer P407). Kollidon VA64 (1 mmol/L, 500 μL) administered intravenously to mice 1 hour after CCI significantly reduced acute cellular degeneration, chronic brain tissue damage, brain edema, blood-brain barrier damage, and postinjury motor deficits (all P<0.05 versus vehicle). However, VA64 did not rescue pulse-labeled PI+ cells from eventual demise. We conclude that PI permeability within 48 hours of CCI is a biomarker of eventual cell death/loss. Kollidon VA64 reduces secondary damage after CCI by mechanisms other than or in addition to resealing permeable cells.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nishijima, M.; Kuge, O.; Akamatsu, Y.
1986-05-05
The effect of phosphatidylserine exogenously added to the medium on de novo biosynthesis of phosphatidylserine was investigated in cultured Chinese hamster ovary cells. When cells were cultured for several generations in medium supplemented with phosphatidylserine and /sup 32/Pi, the incorporation of /sup 32/Pi into cellular phosphatidylserine was remarkably inhibited, the degree of inhibition being dependent upon the concentration of added phosphatidylserine. /sup 32/Pi uptake into cellular phosphatidylethanolamine was also partly reduced by the addition of exogenous phosphatidylserine, consistent with the idea that phosphatidylethanolamine is biosynthesized via decarboxylation of phosphatidylserine. However, incorporation of /sup 32/Pi into phosphatidylcholine, sphingomyelin, and phosphatidylinositol wasmore » not significantly affected. In contrast, the addition of either phosphatidylcholine, sphingomyelin, phosphatidylethanolamine, or phosphatidylinositol to the medium did not inhibit endogenous biosynthesis of the corresponding phospholipid. Radiochemical and chemical analyses of the cellular phospholipid composition revealed that phosphatidylserine in cells grown with 80 microM phosphatidylserine was almost entirely derived from the added phospholipid. Phosphatidylserine uptake was also directly determined by using (/sup 3/H)serine-labeled phospholipid. Pulse and pulse-chase experiments with L-(U-/sup 14/C) serine showed that when cells were cultured with 80 microM phosphatidylserine, the rate of synthesis of phosphatidylserine was reduced 3-5-fold. Enzyme assaying of extracts prepared from cells grown with and without phosphatidylserine indicated that the inhibition of de novo phosphatidylserine biosynthesis by the added phosphatidylserine appeared not to be caused by a reduction in the level of the enzyme involved in the base-exchange reaction between phospholipids and serine.« less
Akyildiz, Basak
2018-01-01
This study compared the accuracy of noninvasively measuring hemoglobin using spectrophotometry (SpHb) with a pulse CO-oximeter and laboratory hemoglobin (Hb) measurements. A total of 345 critically ill children were included prospectively. Age, sex, and factors influencing the reliabilityof SpHb such as SpO2, heart rate, perfusion index (PI), and vasoactive inotropic score were recorded. SpHb measurements were recorded during the blood draw and compared with the Hb measurement. Thirteen patients (low PI in 9 patients and no available Hb in 4 patients) were excluded and 332 children were eligible for final analysis. The mean Hb was 8.71±1.49 g/dL (range, 5.9 to 12 g/dL) and the mean SpHb level was 9.55±1.53 g/dL (range, 6 to 14.2 g/dL). The SpHb bias was 0.84±0.86,with the limits of agreement ranging from -2.5 to 0.9 g/dL. The difference between Hb and SpHb was >1.5 g/dL for only 47 patients. Of these, 24 patients had laboratory Hb levels <7 g/dL. There was a weak positive correlation between differences and PI (r=0.349; P= 0.032). The pulse CO-oximeter is a promising tool for measuring SpHb and monitoring critically ill children. However, PI may affect these results. Additional studies investigating the reliability of the trend of continuous SpHb values compared with simultaneously measured laboratory Hb values in the same patient are warranted.
Chen, Shouyuan; Chini, Michael; Wang, He; Yun, Chenxia; Mashiko, Hiroki; Wu, Yi; Chang, Zenghu
2009-10-20
Carrier-envelope (CE) phase stabilization of a two-stage chirped pulse amplifier laser system with regenerative amplification as the preamplifier is demonstrated. The CE phase stability of this laser system is found to have a 90 mrad rms error averaged over 50 laser shots for a locking period of 4.5 h. The CE phase locking was confirmed unambiguously by experimental observation of the 2pi periodicity of the high-order harmonic spectrum generated by double optical gating.
Ferré, Jean-Christophe; Petr, Jan; Bannier, Elise; Barillot, Christian; Gauvrit, Jean-Yves
2012-05-01
To compare 12-channel and 32-channel phased-array coils and to determine the optimal parallel imaging (PI) technique and factor for brain perfusion imaging using Pulsed Arterial Spin labeling (PASL) at 3 Tesla (T). Twenty-seven healthy volunteers underwent 10 different PASL perfusion PICORE Q2TIPS scans at 3T using 12-channel and 32-channel coils without PI and with GRAPPA or mSENSE using factor 2. PI with factor 3 and 4 were used only with the 32-channel coil. Visual quality was assessed using four parameters. Quantitative analyses were performed using temporal noise, contrast-to-noise and signal-to-noise ratios (CNR, SNR). Compared with 12-channel acquisition, the scores for 32-channel acquisition were significantly higher for overall visual quality, lower for noise and higher for SNR and CNR. With the 32-channel coil, artifact compromise achieved the best score with PI factor 2. Noise increased, SNR and CNR decreased with PI factor. However mSENSE 2 scores were not always significantly different from acquisition without PI. For PASL at 3T, the 32-channel coil at 3T provided better quality than the 12-channel coil. With the 32-channel coil, mSENSE 2 seemed to offer the best compromise for decreasing artifacts without significantly reducing SNR, CNR. Copyright © 2012 Wiley Periodicals, Inc.
Kinai, Ei; Gatanaga, Hiroyuki; Mizushima, Daisuke; Nishijima, Takeshi; Aoki, Takahiro; Genka, Ikumi; Teruya, Katsuji; Tsukada, Kunihisa; Kikuchi, Yoshimi; Oka, Shinichi
2017-05-01
Clinical and experiments evidence indicate that protease inhibitors (PI) can cause bone mineral density (BMD) loss. However, the mechanism of such loss remains obscure. This single-center, cross-sectional study included 184 HIV-infected patients treated with PI who underwent dual-energy X-ray absorptiometry scan. Serum phosphorus, percentage of tubular reabsorption of phosphate (%TRP), thyroid and parathyroid function (iPTH), vitamin D, osteocalcin (OC), urinary deoxypyridinoline (DPD), and urinary cross-linked N-telopeptide of type I collagen (u-NTx) were measured. The rate of hypothyroidism in PI-users [32/117 (27%)] was double that in non-PI users [8/67 (12%), p = 0.016] and was significantly associated with PI use in multivariate analysis [odds ratio (OR) 11.37, 95% confidence interval (CI) 1.358-95.17, p = 0.025]. Spine BMD was significantly lower in hypothyroid patients than euthyroid, for both total population (-1.37 vs. -1.00, p = 0.041) and PI users (-1.56 vs. -1.13, p = 0.029). Multivariate regression analysis identified inverse correlation between hypothyroidism and spine BMD [estimate -0.437, 95% CI -0.858 to -0.024, p = 0.042]. OC, DPD and u-NTx were significantly higher in PI users than in non-PI users (p = 0.01, 0.05, and 0.01, respectively). PI use is associated with hypothyroidism as well as bone turnover acceleration, which worsens PI-associated BMD loss. In PI-treated patients, thyroid function tests are warranted to prevent further progression of PI-associated BMD loss. Copyright © 2016 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Laser Energy Monitor for Double-Pulsed 2-Micrometer IPDA Lidar Application
NASA Technical Reports Server (NTRS)
Refaat, Tamer F.; Petros, Mulugeta; Remus, Ruben; Yu, Jirong; Singh, Upendra N.
2014-01-01
Integrated path differential absorption (IPDA) lidar is a remote sensing technique for monitoring different atmospheric species. The technique relies on wavelength differentiation between strong and weak absorbing features normalized to the transmitted energy. 2-micron double-pulsed IPDA lidar is best suited for atmospheric carbon dioxide measurements. In such case, the transmitter produces two successive laser pulses separated by short interval (200 microseconds), with low repetition rate (10Hz). Conventional laser energy monitors, based on thermal detectors, are suitable for low repetition rate single pulse lasers. Due to the short pulse interval in double-pulsed lasers, thermal energy monitors underestimate the total transmitted energy. This leads to measurement biases and errors in double-pulsed IPDA technique. The design and calibration of a 2-micron double-pulse laser energy monitor is presented. The design is based on a high-speed, extended range InGaAs pin quantum detectors suitable for separating the two pulse events. Pulse integration is applied for converting the detected pulse power into energy. Results are compared to a photo-electro-magnetic (PEM) detector for impulse response verification. Calibration included comparing the three detection technologies in single-pulsed mode, then comparing the pin and PEM detectors in double-pulsed mode. Energy monitor linearity will be addressed.
2013-09-30
unclassified c. THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 2 Co-PI: Christopher K. R. T. Jones ...Co-PI: Stefan Llewellyn Smith Department of Mechanical and Aerospace Engineering University of California, San Diego 9500 Gilman Drive La...systems but looking a weakly 3D systems for long time intervals. ( Llewellyn Smith) Figure 10. We are exploring the effects of submesoscale motions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hosokai, Tomonao; Zhidkov, Alexei; Yamazaki, Atsushi
2010-03-22
Hundred-mega-electron-volt electron beams with quasi-monoenergetic distribution, and a transverse geometrical emittance as small as approx0.02 pi mm mrad are generated by low power (7 TW, 45 fs) laser pulses tightly focused in helium gas jets in an external static magnetic field, Bapprox1 T. Generation of monoenergetic beams strongly correlates with appearance of a straight, at least 2 mm length plasma channel in a short time before the main laser pulse and with the energy of copropagating picosecond pedestal pulses (PPP). For a moderate energy PPP, the multiple or staged electron self-injection in the channel gives several narrow peaks in themore » electron energy distribution.« less
a New Approach for Accuracy Improvement of Pulsed LIDAR Remote Sensing Data
NASA Astrophysics Data System (ADS)
Zhou, G.; Huang, W.; Zhou, X.; He, C.; Li, X.; Huang, Y.; Zhang, L.
2018-05-01
In remote sensing applications, the accuracy of time interval measurement is one of the most important parameters that affect the quality of pulsed lidar data. The traditional time interval measurement technique has the disadvantages of low measurement accuracy, complicated circuit structure and large error. A high-precision time interval data cannot be obtained in these traditional methods. In order to obtain higher quality of remote sensing cloud images based on the time interval measurement, a higher accuracy time interval measurement method is proposed. The method is based on charging the capacitance and sampling the change of capacitor voltage at the same time. Firstly, the approximate model of the capacitance voltage curve in the time of flight of pulse is fitted based on the sampled data. Then, the whole charging time is obtained with the fitting function. In this method, only a high-speed A/D sampler and capacitor are required in a single receiving channel, and the collected data is processed directly in the main control unit. The experimental results show that the proposed method can get error less than 3 ps. Compared with other methods, the proposed method improves the time interval accuracy by at least 20 %.
Pitkänen, Minna; Kallioniemi, Elisa; Julkunen, Petro
2017-01-01
Repetition suppression (RS) is evident as a weakened response to repeated stimuli after the initial response. RS has been demonstrated in motor-evoked potentials (MEPs) induced with transcranial magnetic stimulation (TMS). Here, we investigated the effect of inter-train interval (ITI) on the induction of RS of MEPs with the attempt to optimize the investigative protocols. Trains of TMS pulses, targeted to the primary motor cortex by neuronavigation, were applied at a stimulation intensity of 120% of the resting motor threshold. The stimulus trains included either four or twenty pulses with an inter-stimulus interval (ISI) of 1 s. The ITI was here defined as the interval between the last pulse in a train and the first pulse in the next train; the ITIs used here were 1, 3, 4, 6, 7, 12, and 17 s. RS was observed with all ITIs except with the ITI of 1 s, in which the ITI was equal to ISI. RS was more pronounced with longer ITIs. Shorter ITIs may not allow sufficient time for a return to baseline. RS may reflect a startle-like response to the first pulse of a train followed by habituation. Longer ITIs may allow more recovery time and in turn demonstrate greater RS. Our results indicate that RS can be studied with confidence at relatively short ITIs of 6 s and above.
NASA Astrophysics Data System (ADS)
Hashimura, Keisuke; Ishii, Katsunori; Awazu, Kunio
2016-03-01
Cholesteryl esters are main components of atherosclerotic plaques and have an absorption peak at the wavelength of 5.75 μm originated from C=O stretching vibration mode of ester bond. Our group achieved the selective ablation of atherosclerotic lesions using a quantum cascade laser (QCL) in the 5.7 μm wavelength range. QCLs are relatively new types of semiconductor lasers that can emit mid-infrared range. They are sufficiently compact and considered to be useful for clinical application. However, large thermal effects were observed because the QCL worked as quasicontinuous wave (CW) lasers due to its short pulse interval. Then we tried macro pulse irradiation (irradiation of pulses at intervals) of the QCL and achieved effective ablation with less-thermal effects than conventional quasi-CW irradiation. However, lesion selectivity might be changed by changing pulse structure. Therefore, in this study, irradiation effects of the macro pulse irradiation to rabbit atherosclerotic plaque and normal vessel were compared. The macro pulse width and the macro pulse interval were set to 0.5 and 12 ms, respectively, because the thermal relaxation time of rabbit normal and atherosclerotic aortas in the oscillation wavelength of the QCL was 0.5-12 ms. As a result, cutting difference was achieved between rabbit atherosclerotic and normal aortas by the macro pulse irradiation. Therefore, macro pulse irradiation of a QCL in the 5.7 μm wavelength range is effective for reducing thermal effects and selective ablation of the atherosclerotic plaque. QCLs have the potential of realizing less-invasive laser angioplasty.
Barker, Alan F; Campos, Michael A; Brantly, Mark L; Stocks, James M; Sandhaus, Robert A; Lee, Douglas; Steinmann, Kimberly; Lin, Jiang; Sorrells, Susan
2017-12-01
This study evaluated the bioequivalence, safety, and immunogenicity of a new liquid formulation of human plasma-derived alpha 1 -proteinase inhibitor, Liquid Alpha 1 -PI, compared with the Lyophilized Alpha 1 -PI formulation (Prolastin®-C), for augmentation therapy in patients with alpha 1 -antitrypsin deficiency (AATD). In this double-blind, randomized, 20-week crossover study, 32 subjects with AATD were randomized to receive 8 weekly infusions of 60 mg/kg of Liquid Alpha 1 -PI or Lyophilized Alpha 1 -PI. Serial blood samples were drawn for 7 days after the last dose followed by 8 weeks of the alternative treatment. The primary endpoint was bioequivalence at steady state, as measured by area under the concentration versus time curve from 0 to 7 days (AUC 0-7 days ) postdose using an antigenic content assay. Bioequivalence was defined as 90% confidence interval (CI) for the ratio of the geometric least squares (LS) mean of AUC 0-7 days for both products within the limits of 0.80 and 1.25. Safety and immunogenicity were assessed. Mean alpha 1 -PI concentration versus time curves for both formulations were superimposable. Mean AUC 0-7 days was 20 320 versus 19 838 mg × h/dl for Liquid Alpha 1 -PI and Lyophilized Alpha 1 -PI, respectively. The LS mean ratio of AUC 0-7 days (90% CI) for Liquid Alpha 1 -PI versus Lyophilized Alpha 1 -PI was 1.05 (1.03-1.08), indicating bioequivalence. Liquid Alpha 1 -PI was well tolerated and adverse events were consistent with Lyophilized Alpha 1 -PI. Immunogenicity to either product was not detected. In conclusion, Liquid Alpha 1 -PI is bioequivalent to Lyophilized Alpha 1 -PI, with a similar safety profile. The liquid formulation would eliminate the need for reconstitution and shorten preparation time for patients receiving augmentation therapy for AATD.
Festini, Sara B; Reuter-Lorenz, Patricia A
2014-03-01
Proactive interference (PI) occurs when previously learned information interferes with new learning. In a working memory task, PI induces longer response times and more errors to recent negative probes than to new probes, presumably because the recent probe's familiarity invites a "yes" response. Warnings, longer intertrial intervals, and the increased contextual salience of the probes can reduce but not eliminate PI, suggesting that cognitive control over PI is limited. Here we tested whether control exerted in the form of intentional forgetting performed during working memory can reduce the magnitude of PI. In two experiments, participants performed a working memory task with directed-forgetting instructions and the occasional presentation of recent probes. Surprise long-term memory testing indicated better memory for to-be-remembered than for to-be-forgotten items, documenting the classic directed-forgetting effect. Critically, in working memory, PI was virtually eliminated for recent probes from prior to-be-forgotten lists, as compared to recent probes from prior to-be-remembered lists. Thus cognitive control, when executed via directed forgetting, can reduce the adverse and otherwise persistent interference from familiarity, an effect that we attribute to attenuated memory representations of the to-be-forgotten items.
Detecting Pulsing Denial-of-Service Attacks with Nondeterministic Attack Intervals
NASA Astrophysics Data System (ADS)
Luo, Xiapu; Chan, Edmond W. W.; Chang, Rocky K. C.
2009-12-01
This paper addresses the important problem of detecting pulsing denial of service (PDoS) attacks which send a sequence of attack pulses to reduce TCP throughput. Unlike previous works which focused on a restricted form of attacks, we consider a very broad class of attacks. In particular, our attack model admits any attack interval between two adjacent pulses, whether deterministic or not. It also includes the traditional flooding-based attacks as a limiting case (i.e., zero attack interval). Our main contribution is Vanguard, a new anomaly-based detection scheme for this class of PDoS attacks. The Vanguard detection is based on three traffic anomalies induced by the attacks, and it detects them using a CUSUM algorithm. We have prototyped Vanguard and evaluated it on a testbed. The experiment results show that Vanguard is more effective than the previous methods that are based on other traffic anomalies (after a transformation using wavelet transform, Fourier transform, and autocorrelation) and detection algorithms (e.g., dynamic time warping).
Resonant Frequency Control For the PIP-II Injector Test RFQ: Control Framework and Initial Results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Edelen, A. L.; Biedron, S. G.; Milton, S. V.
For the PIP-II Injector Test (PI-Test) at Fermilab, a four-vane radio frequency quadrupole (RFQ) is designed to accelerate a 30-keV, 1-mA to 10-mA, H- beam to 2.1 MeV under both pulsed and continuous wave (CW) RF operation. The available headroom of the RF amplifiers limits the maximum allowable detuning to 3 kHz, and the detuning is controlled entirely via thermal regulation. Fine control over the detuning, minimal manual intervention, and fast trip recovery is desired. In addition, having active control over both the walls and vanes provides a wider tuning range. For this, we intend to use model predictive controlmore » (MPC). To facilitate these objectives, we developed a dedicated control framework that handles higher-level system decisions as well as executes control calculations. It is written in Python in a modular fashion for easy adjustments, readability, and portability. Here we describe the framework and present the first control results for the PI-Test RFQ under pulsed and CW operation.« less
Zhang, Zhongheng; Xu, Xiao; Yao, Min; Chen, Huilan; Ni, Hongying; Fan, Haozhe
2013-02-01
Hemodynamic monitoring is very important in critically ill patients with shock or acute respiratory distress syndrome(ARDS). The PiCCO (Pulse index Contour Continuous Cardiac Output, Pulsion Medical Systems, Germany) system has been developed and used in critical care settings for several years. However, its impact on clinical outcomes remains unknown. The study is a randomized controlled multi-center trial. A total of 708 patients with ARDS, septic shock or both will be included from January 2012 to January 2014. Subjects will be randomized to receive PiCCO monitoring or not. Our primary end point is 30-day mortality, and secondary outcome measures include ICU length of stay, days on mechanical ventilation, days of vasoactive agent support, ICU-free survival days during a 30-day period, mechanical-ventilation-free survival days during a 30-day period, and maximum SOFA score during the first 7 days. We investigate whether the use of PiCCO monitoring will improve patient outcomes in critically ill patients with ARDS or septic shock. This will provide additional data on hemodynamic monitoring and help clinicians to make decisions on the use of PiCCO. http://www.clinicaltrials.gov NCT01526382.
The determination of the pulse pile-up reject (PUR) counting for X and gamma ray spectrometry
NASA Astrophysics Data System (ADS)
Karabıdak, S. M.; Kaya, S.
2017-02-01
The collection the charged particles produced by the incident radiation on a detector requires a time interval. If this time interval is not sufficiently short compared with the peaking time of the amplifier, a loss in the recovered signal amplitude occurs. Another major constraint on the throughput of modern x or gamma-ray spectrometers is the time required for the subsequent the pulse processing by the electronics. Two above-mentioned limitations are cause of counting losses resulting from the dead time and the pile-up. The pulse pile-up is a common problem in x and gamma ray radiation detection systems. The pulses pile-up in spectroscopic analysis can cause significant errors. Therefore, inhibition of these pulses is a vital step. A way to reduce errors due to the pulse pile-up is a pile-up inspection circuitry (PUR). Such a circuit rejects some of the pulse pile-up. Therefore, this circuit leads to counting losses. Determination of these counting losses is an important problem. In this work, a new method is suggested for the determination of the pulse pile-up reject.
Doubly-excited pulse-waves on flowing liquid films: experiments and numerical simulations
NASA Astrophysics Data System (ADS)
Adebayo, Idris; Xie, Zhihua; Che, Zhizhao; Wray, Alex; Matar, Omar
2016-11-01
The interaction patterns between doubly-excited pulse waves on a flowing liquid film are studied both experimentally and numerically. The flowing film is constituted on an inclined glass substrate while pulse-waves are excited on the film surface by means of a solenoid valve connected to a relay which receives signals from customised Matlab routines. The effect of varying the system parameters i.e. film flow rate, inter-pulse interval and substrate inclination angle on the pulse interaction patterns are then studied. Results show that different interaction patterns exist for these binary pulses; which include a singular behaviour, complete merger, partial merger and total non-coalescence. A regime map of these patterns is then plotted for each inclination angles examined, based on the film Re and the inter-pulse interval. Finally, the individual effect of the system parameters on the merging distance of these binary pulses in the merger mode is then studied and the results validated using both numerical simulations and mathematical modelling. Funding from the Nigerian Government (for Idris Adebayo), and the EPSRC through a programme Grant MEMPHIS (EP/K003976/1) gratefully acknowledged.
Time-resolved speckle effects on the estimation of laser-pulse arrival times
NASA Technical Reports Server (NTRS)
Tsai, B.-M.; Gardner, C. S.
1985-01-01
A maximum-likelihood (ML) estimator of the pulse arrival in laser ranging and altimetry is derived for the case of a pulse distorted by shot noise and time-resolved speckle. The performance of the estimator is evaluated for pulse reflections from flat diffuse targets and compared with the performance of a suboptimal centroid estimator and a suboptimal Bar-David ML estimator derived under the assumption of no speckle. In the large-signal limit the accuracy of the estimator was found to improve as the width of the receiver observational interval increases. The timing performance of the estimator is expected to be highly sensitive to background noise when the received pulse energy is high and the receiver observational interval is large. Finally, in the speckle-limited regime the ML estimator performs considerably better than the suboptimal estimators.
Characterization of Novel Missense Variants of SERPINA1 Gene Causing Alpha-1 Antitrypsin Deficiency.
Matamala, Nerea; Lara, Beatriz; Gomez-Mariano, Gema; Martínez, Selene; Retana, Diana; Fernandez, Taiomara; Silvestre, Ramona Angeles; Belmonte, Irene; Rodriguez-Frias, Francisco; Vilar, Marçal; Sáez, Raquel; Iturbe, Igor; Castillo, Silvia; Molina-Molina, María; Texido, Anna; Tirado-Conde, Gema; Lopez-Campos, Jose Luis; Posada, Manuel; Blanco, Ignacio; Janciauskiene, Sabina; Martinez-Delgado, Beatriz
2018-06-01
The SERPINA1 gene is highly polymorphic, with more than 100 variants described in databases. SERPINA1 encodes the alpha-1 antitrypsin (AAT) protein, and severe deficiency of AAT is a major contributor to pulmonary emphysema and liver diseases. In Spanish patients with AAT deficiency, we identified seven new variants of the SERPINA1 gene involving amino acid substitutions in different exons: PiSDonosti (S+Ser14Phe), PiTijarafe (Ile50Asn), PiSevilla (Ala58Asp), PiCadiz (Glu151Lys), PiTarragona (Phe227Cys), PiPuerto Real (Thr249Ala), and PiValencia (Lys328Glu). We examined the characteristics of these variants and the putative association with the disease. Mutant proteins were overexpressed in HEK293T cells, and AAT expression, polymerization, degradation, and secretion, as well as antielastase activity, were analyzed by periodic acid-Schiff staining, Western blotting, pulse-chase, and elastase inhibition assays. When overexpressed, S+S14F, I50N, A58D, F227C, and T249A variants formed intracellular polymers and did not secrete AAT protein. Both the E151K and K328E variants secreted AAT protein and did not form polymers, although K328E showed intracellular retention and reduced antielastase activity. We conclude that deficient variants may be more frequent than previously thought and that their discovery is possible only by the complete sequencing of the gene and subsequent functional characterization. Better knowledge of SERPINA1 variants would improve diagnosis and management of individuals with AAT deficiency.
Zhou, Jing; Han, Yi
2016-01-01
To analyze the ability of pleth variability index (PVI) and respiratory system compliance (RSC) on evaluating the hemodynamic and respiratory effects of positive end expiratory pressure (PEEP), then to direct PEEP settings in mechanically ventilated critical patients. We studied 22 mechanically ventilated critical patients in the intensive care unit. Patients were monitored with classical monitor and a pulse co-oximeter, with pulse sensors attached to patients' index fingers. Hemodynamic data [heart rate (HR), perfusion index (PI), PVI, central venous pressure (CVP), mean arterial pressure (MAP), peripheral blood oxygen saturation (SPO2), peripheral blood oxygen content (SPOC) and peripheral blood hemoglobin (SPHB)] as well as the respiratory data [respiratory rate (RR), tidal volume (VT), RSC and controlled airway pressure] were recorded for 15 min each at 3 different levels of PEEP (0, 5 and 10 cmH2O). Different levels of PEEP (0, 5 and 10 cmH2O) had no obvious effect on RR, HR, MAP, SPO2 and SPOC. However, 10 cmH2O PEEP induced significant hemodynamic disturbances, including decreases of PI, and increases of both PVI and CVP. Meanwhile, 5 cmH2O PEEP induced no significant changes on hemodynamics such as CVP, PI and PVI, but improved the RSC. RSC and PVI may be useful in detecting the hemodynamic and respiratory effects of PEEP, thus may help clinicians individualize PEEP settings in mechanically ventilated patients.
Phase-matching of attosecond XUV supercontinuum
NASA Astrophysics Data System (ADS)
Gilbertson, Steve; Mashiko, Hiroki; Li, Chengquan; Khan, Sabih; Shakya, Mahendra; Moon, Eric; Chang, Zenghu
2008-05-01
Adding a weak second harmonic field to an ellipticity dependent polarization gating field allowed for the production of XUV supercontinua from longer (˜10 fs) input pulses in argon. The spectra support 200 as single isolated pulses. This technique, dubbed double optical gating (DOG), demonstrated a large enhancement of the harmonic yield as compared with polarization gating. These results can be attributed to the reduced depletion of the ground state of the target from the leading edge of the pulse and the increased intensity inside the polarization gate width. Through optimization of the harmonic generation process under the phase matching conditions, we were able to further increase the harmonic flux. The parameters included the target gas pressure, laser focus position, input pulse duration, and polarization gate width. By varying the CE phase of the pulse, we were able to verify that the results were indeed from DOG due to its unique 2 pi dependence on the harmonic spectrum. We were able to extend our results to neon. Its higher ionization potential allowed an extension of the harmonic cutoff for the production of even shorter pulses.
Zaugg, Serge; van der Schaar, Mike; Houégnigan, Ludwig; André, Michel
2013-02-01
The analysis of acoustic data from the ocean is a valuable tool to study free ranging cetaceans and anthropogenic noise. Due to the typically large volume of acquired data, there is a demand for automated analysis techniques. Many cetaceans produce acoustic pulses (echolocation clicks) with a pulse repetition interval (PRI) remaining nearly constant over several pulses. Analyzing these pulse trains is challenging because they are often interleaved. This article presents an algorithm that estimates a pulse's PRI with respect to neighboring pulses. It includes a deinterleaving step that operates via a spectral dissimilarity metric. The sperm whale (SW) produces trains with PRIs between 0.5 and 2 s. As a validation, the algorithm was used for the PRI-based identification of SW click trains with data from the NEMO-ONDE observatory that contained other pulsed sounds, mainly from ship propellers. Separation of files containing SW clicks with a medium and high signal to noise ratio from files containing other pulsed sounds gave an area under the receiver operating characteristic curve value of 0.96. This study demonstrates that PRI can be used for the automated identification of SW clicks and that deinterleaving via spectral dissimilarity contributes to algorithm performance.
NASA Astrophysics Data System (ADS)
Knyaz'kov, A.; Pustovykh, O.; Verevkin, A.; Terekhin, V.; Shachek, A.; Tyasto, A.
2016-04-01
It is shown that in order to form the current pulse of a near rectangular shape, which provides conversion of the welding arc into a dynamic mode, it is rational to connect a forming element made on the basis of an artificial forming line in series to the welding DC circuit. The paper presents a diagram of a pulsed device for welding with a non-consumable electrode in argon which was developed using the forming element. The conversion of the arc into the dynamic mode is illustrated by the current and voltage oscillograms of the arc gap and the dynamic characteristic of the arc within the interval of one pulse generation time in the arc gap. The background current travels in the interpulse interval.
Kurtz, J E; Lee, P A; Sherker, J L
1999-06-01
This study examines the internal consistency and temporal stability of informant ratings from two widely used instruments for normal personality assessment, the revised NEO Personality Inventory (NEO PI-R) and the Interpersonal Adjective Scales (IAS). Well-known adult targets were selected by 109 undergraduate students and rated on two occasions separated by a 6-month interval. With few exceptions, estimates of internal consistency are adequate to good for both instruments. NEO PI-R domain scores yield coefficient alphas ranging from .89 to .96, with a median of .80 for the 30 facet scales. IAS octant scales show coefficient alphas ranging from .83 to .92. Retest Pearson correlations are above .70 for each of the NEO PI-R domain scores and both IAS axis coordinates, and intraclass correlations are above .60 for all scales from both instruments. Score changes were small but statistically significant for three of the five NEO PI-R domains at retest. The retest stability of IAS type classifications varies as a function of the extremity of the associated octant scores.
Rahimi-Golkhandan, S; Maruff, P; Darby, D; Wilson, P
2012-11-01
Proactive interference (PI) that remains unidentified can confound the assessment of verbal learning, particularly when its effects vary from one population to another. The International Shopping List Task (ISLT) is a new measure that provides multiple forms that can be equated for linguistic factors across cultural groups. The aim of this study was to examine the build-up of PI on two measures of verbal learning-a traditional test of list learning (Rey Auditory Verbal Learning Test, RAVLT) and the ISLT. The sample consisted of 61 healthy adults aged 18-40. Each test had three parallel forms, each recalled three times. Results showed that repeated administration of the ISLT did not result in significant PI effects, unlike the RAVLT. Although these PI effects, observed during short retest intervals, may not be as robust under normal clinical administrations of the tests, the results suggest that the choice of the verbal learning test should be guided by the knowledge of PI effects and the susceptibility of particular patient groups to this effect.
Laser detection of material thickness
Early, James W.
2002-01-01
There is provided a method for measuring material thickness comprising: (a) contacting a surface of a material to be measured with a high intensity short duration laser pulse at a light wavelength which heats the area of contact with the material, thereby creating an acoustical pulse within the material: (b) timing the intervals between deflections in the contacted surface caused by the reverberation of acoustical pulses between the contacted surface and the opposite surface of the material: and (c) determining the thickness of the material by calculating the proportion of the thickness of the material to the measured time intervals between deflections of the contacted surface.
Orthogonal on-off control of radar pulses for the suppression of mutual interference
NASA Astrophysics Data System (ADS)
Kim, Yong Cheol
1998-10-01
Intelligent vehicles of the future will be guided by radars and other sensors to avoid obstacles. When multiple vehicles move simultaneously in autonomous navigational mode, mutual interference among car radars becomes a serious problem. An obstacle is illuminated with electromagnetic pulses from several radars. The signal at a radar receiver is actually a mixture of the self-reflection and the reflection of interfering pulses emitted by others. When standardized pulse- type radars are employed on vehicles for obstacle avoidance and so self-pulse and interfering pulses have identical pulse repetition interval, this SI (synchronous Interference) is very difficult to separate from the true reflection. We present a method of suppressing such a synchronous interference. By controlling the pulse emission of a radar in a binary orthogonal ON, OFF pattern, the true self-reflection can be separated from the false one. Two range maps are generated, TRM (true-reflection map) and SIM (synchronous- interference map). TRM is updated for every ON interval and SIM is updated for every OFF interval of the self-radar. SIM represents the SI of interfering radars while TRM keeps a record of a mixture of the true self-reflection and SI. Hence the true obstacles can be identified by the set subtraction operation. The performance of the proposed method is compared with that of the conventional M of N method. Bayesian analysis shows that the probability of false alarm is improved by order of 103 to approximately 106 while the deterioration in the probability of detection is negligible.
NASA Astrophysics Data System (ADS)
Shi, Yongli; Wu, Zhong; Zhi, Kangyi; Xiong, Jun
2018-03-01
In order to realize reliable commutation of brushless DC motors (BLDCMs), a simple approach is proposed to detect and correct signal faults of Hall position sensors in this paper. First, the time instant of the next jumping edge for Hall signals is predicted by using prior information of pulse intervals in the last electrical period. Considering the possible errors between the predicted instant and the real one, a confidence interval is set by using the predicted value and a suitable tolerance for the next pulse edge. According to the relationship between the real pulse edge and the confidence interval, Hall signals can be judged and the signal faults can be corrected. Experimental results of a BLDCM at steady speed demonstrate the effectiveness of the approach.
Llurba, Elisa; Turan, Ozhan; Kasdaglis, Tania; Harman, Chris R; Baschat, Ahmet A
2013-06-01
To test if emergence of third-trimester (T3) placental dysfunction is related to the impedance change in uterine artery blood flow resistance between the first trimester (T1) and T3. Mean T1 and T3 uterine artery (mUtA) pulsatility index (PI) was measured in 1098 singletons. Each patient's individual mUtA-PI change was calculated ([(T3 PI - T1 PI/interval in days)] × 100; ΔmUtA-PI). This parameter and T1 and T3 mUtA-PI z-scores were related to placenta-related disease (PRD) and to constitutionally small neonates (CS). Forty-seven (5%) women had PRD and 83 (8.7%) delivered a CS neonate. T1 and T3 mUtA-PI z-scores were higher with PRD (0.418 versus -0.097 and 1.06 versus -0.13, p < 0.001 for all). Change in mUtA-PI (ΔmUtA PI) was similar for patients with PRD. However, the prevalence of PRD doubled with rising ΔmUtA-PI (11.1% versus 5.2%, p = 0.041). T3 uterine artery Doppler performs significantly better in detecting patients at risk for late-onset PRD than T1 or the gestational age change in uterine artery Doppler resistance This suggests that a proportion of late emerging PRD is not amenable to early screening by uterine artery Doppler. Further research is essential to identify the optimal screening strategy for late-onset placental dysfunction. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
MEASUREMENT OF TIME INTERVALS FOR TIME CORRELATED RADIOACTIVE DECAY
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lindeman, H.; Mornel, E.; Galil, U.
1960-11-01
The distribution of time intervals between successive counts was measured for radioactive decay in the thorium series. The measurements showed that the classical Marsden-Barratt law does not apply to this case of timecorrelated decay. They appeared, however, to be in agreement with the theory of Lindeman-Rosen, taking into account the fact that the counter receives only the radiation emitted in a solid angle near to 2 pi . (auth)
Pump-dump iterative squeezing of vibrational wave packets.
Chang, Bo Y; Sola, Ignacio R
2005-12-22
The free motion of a nonstationary vibrational wave packet in an electronic potential is a source of interesting quantum properties. In this work we propose an iterative scheme that allows continuous stretching and squeezing of a wave packet in the ground or in an excited electronic state, by switching the wave function between both potentials with pi pulses at certain times. Using a simple model of displaced harmonic oscillators and delta pulses, we derive the analytical solution and the conditions for its possible implementation and optimization in different molecules and electronic states. We show that the main constraining parameter is the pulse bandwidth. Although in principle the degree of squeezing (or stretching) is not bounded, the physical resources increase quadratically with the number of iterations, while the achieved squeezing only increases linearly.
Angell-James, Jennifer E.; Daly, M. de Burgh
1973-01-01
1. The effects on respiration and pulse interval of stimulation of the carotid body chemoreceptors before, during and after stimulation of receptors in the nose have been studied in the anaesthetized dog. 2. Stimulation of a carotid body by infusion of cyanide into the ipsi-lateral common carotid artery causes hyperpnoea and either an increase, decrease or no change in pulse interval. 3. Excitation of receptors in the nasal mucosa leads to reflex apnoea or a reduction in breathing, and an increase in pulse interval. 4. When the carotid bodies are excited by the same dose of cyanide during stimulation of the nasal mucosa, the chemoreceptor-respiratory response is abolished or reduced in size compared with the control effect. On the other hand, the chemoreceptor-cardio-inhibitory response is considerably enhanced. 5. The potentiated cardio-inhibitory response of combined chemoreceptor and nasal stimulation could not be accounted for by the change in pulmonary ventilation, arterial PO2 or PCO2, or mean arterial blood pressure. 6. These results indicate that excitation of the nasal reflex inhibits the chemoreceptor-respiratory reflex response but facilitates the chemoreceptor-cardio-inhibitory reflex response. The possible sites of these interactions between the nasal and chemoreceptor reflexes are discussed. PMID:4689961
Jayasinghe, Sisitha U.; Torres, Susan J.; Hussein, Mais; Fraser, Steve F.; Lambert, Gavin W.; Turner, Anne I.
2017-01-01
According to the ‘cross stressor adaptation hypothesis’, regular exercise acts as a buffer against the detrimental effects of stress. Nevertheless, evidence that higher levels of cardiorespiratory fitness moderate hemodynamic responses to acute psychological stress is inconclusive, especially in women. Women aged 30–50 years (in the mid-follicular phase of the menstrual cycle) with higher (n = 17) and lower (n = 17) levels of fitness were subjected to a Trier Social Stress Test (TSST). Continuous, non-invasive measurements were made of beat-to-beat, systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), heart rate (HR), stroke volume (SV), cardiac output (CO), left ventricular ejection time (LVET), maximum slope, pulse interval (PI) and total peripheral resistance (TPR). Maximal oxygen consumption was significantly (p<0.001) higher in the ‘higher fit’ women. Lower fit women had higher fasting glucose, resting heart rate, waist to hip ratios and elevated serum triglyceride and cholesterol/ HDL ratios compared with higher fit women (p<0.05 for all). While all measured parameters (for both groups)displayed significant (p<0.001) responses to the TSST, only HR, PI and LVET differed significantly between higher and lower fit women (p<0.001 for all) with the higher fit women having the larger response in each case. It was also found that higher fit women had significantly shorter time to recovery for maximum slope compared with the lower fit women. These findings provide little support for the notion that higher levels of cardiorespiratory fitness result in lower cardiovascular responsivity to psychological stress in women but may indicate that lower fit women have blunted responses to stress. PMID:28081200
Tivnan, Matthew; Gurjar, Rajan; Wolf, David E; Vishwanath, Karthik
2015-08-12
Diffuse Correlation Spectroscopy (DCS) is a well-established optical technique that has been used for non-invasive measurement of blood flow in tissues. Instrumentation for DCS includes a correlation device that computes the temporal intensity autocorrelation of a coherent laser source after it has undergone diffuse scattering through a turbid medium. Typically, the signal acquisition and its autocorrelation are performed by a correlation board. These boards have dedicated hardware to acquire and compute intensity autocorrelations of rapidly varying input signal and usually are quite expensive. Here we show that a Raspberry Pi minicomputer can acquire and store a rapidly varying time-signal with high fidelity. We show that this signal collected by a Raspberry Pi device can be processed numerically to yield intensity autocorrelations well suited for DCS applications. DCS measurements made using the Raspberry Pi device were compared to those acquired using a commercial hardware autocorrelation board to investigate the stability, performance, and accuracy of the data acquired in controlled experiments. This paper represents a first step toward lowering the instrumentation cost of a DCS system and may offer the potential to make DCS become more widely used in biomedical applications.
Tivnan, Matthew; Gurjar, Rajan; Wolf, David E.; Vishwanath, Karthik
2015-01-01
Diffuse Correlation Spectroscopy (DCS) is a well-established optical technique that has been used for non-invasive measurement of blood flow in tissues. Instrumentation for DCS includes a correlation device that computes the temporal intensity autocorrelation of a coherent laser source after it has undergone diffuse scattering through a turbid medium. Typically, the signal acquisition and its autocorrelation are performed by a correlation board. These boards have dedicated hardware to acquire and compute intensity autocorrelations of rapidly varying input signal and usually are quite expensive. Here we show that a Raspberry Pi minicomputer can acquire and store a rapidly varying time-signal with high fidelity. We show that this signal collected by a Raspberry Pi device can be processed numerically to yield intensity autocorrelations well suited for DCS applications. DCS measurements made using the Raspberry Pi device were compared to those acquired using a commercial hardware autocorrelation board to investigate the stability, performance, and accuracy of the data acquired in controlled experiments. This paper represents a first step toward lowering the instrumentation cost of a DCS system and may offer the potential to make DCS become more widely used in biomedical applications. PMID:26274961
NASA Astrophysics Data System (ADS)
Barengoltz, Jack
2016-07-01
Monte Carlo (MC) is a common method to estimate probability, effectively by a simulation. For planetary protection, it may be used to estimate the probability of impact P{}_{I} by a launch vehicle (upper stage) of a protected planet. The object of the analysis is to provide a value for P{}_{I} with a given level of confidence (LOC) that the true value does not exceed the maximum allowed value of P{}_{I}. In order to determine the number of MC histories required, one must also guess the maximum number of hits that will occur in the analysis. This extra parameter is needed because a LOC is desired. If more hits occur, the MC analysis would indicate that the true value may exceed the specification value with a higher probability than the LOC. (In the worst case, even the mean value of the estimated P{}_{I} might exceed the specification value.) After the analysis is conducted, the actual number of hits is, of course, the mean. The number of hits arises from a small probability per history and a large number of histories; these are the classic requirements for a Poisson distribution. For a known Poisson distribution (the mean is the only parameter), the probability for some interval in the number of hits is calculable. Before the analysis, this is not possible. Fortunately, there are methods that can bound the unknown mean for a Poisson distribution. F. Garwoodfootnote{ F. Garwood (1936), ``Fiduciary limits for the Poisson distribution.'' Biometrika 28, 437-442.} published an appropriate method that uses the Chi-squared function, actually its inversefootnote{ The integral chi-squared function would yield probability α as a function of the mean µ and an actual value n.} (despite the notation used): This formula for the upper and lower limits of the mean μ with the two-tailed probability 1-α depends on the LOC α and an estimated value of the number of "successes" n. In a MC analysis for planetary protection, only the upper limit is of interest, i.e., the single-tailed distribution. (Smaller actual P{}_{I }is no problem.) {}_{ } One advantage of this method is that this function is available in EXCEL. Note that care must be taken with the definition of the CHIINV function (the inverse of the integral chi-squared distribution). The equivalent inequality in EXCEL is μ < CHIINV[1-α, 2(n+1)] In practice, one calculates this upper limit for a specified LOC, α , and a guess of how many hits n will be found after the MC analysis. Then the estimate of the number of histories required is this upper limit divided by the specification for the allowed P{}_{I} (rounded up). However, if the number of hits actually exceeds the guess, the P{}_{I} requirement will be met only with a smaller LOC. A disadvantage is that the intervals about the mean are "in general too wide, yielding coverage probabilities much greater than 1- α ." footnote{ G. Casella and C. Robert (1988), Purdue University-Technical Report #88-7 or Cornell University-Technical Report BU-903-M.} For planetary protection, this technical issue means that the upper limit of the interval and the probability associated with the interval (i.e., the LOC) are conservative.
Hart, Corey B.; Giszter, Simon F.
2013-01-01
We present and apply a method that uses point process statistics to discriminate the forms of synergies in motor pattern data, prior to explicit synergy extraction. The method uses electromyogram (EMG) pulse peak timing or onset timing. Peak timing is preferable in complex patterns where pulse onsets may be overlapping. An interval statistic derived from the point processes of EMG peak timings distinguishes time-varying synergies from synchronous synergies (SS). Model data shows that the statistic is robust for most conditions. Its application to both frog hindlimb EMG and rat locomotion hindlimb EMG show data from these preparations is clearly most consistent with synchronous synergy models (p < 0.001). Additional direct tests of pulse and interval relations in frog data further bolster the support for synchronous synergy mechanisms in these data. Our method and analyses support separated control of rhythm and pattern of motor primitives, with the low level execution primitives comprising pulsed SS in both frog and rat, and both episodic and rhythmic behaviors. PMID:23675341
Time-of-flight direct recoil ion scattering spectrometer
Krauss, A.R.; Gruen, D.M.; Lamich, G.J.
1994-09-13
A time-of-flight direct recoil and ion scattering spectrometer beam line is disclosed. The beam line includes an ion source which injects ions into pulse deflection regions and separated by a drift space. A final optics stage includes an ion lens and deflection plate assembly. The ion pulse length and pulse interval are determined by computerized adjustment of the timing between the voltage pulses applied to the pulsed deflection regions. 23 figs.
Prefire identification for pulse-power systems
Longmire, J.L.; Thuot, M.E.; Warren, D.S.
1982-08-23
Prefires in a high-power, high-frequency, multi-stage pulse generator are detected by a system having an EMI shielded pulse timing transmitter associated with and tailored to each stage of the pulse generator. Each pulse timing transmitter upon detection of a pulse triggers a laser diode to send an optical signal through a high frequency fiber optic cable to a pulse timing receiver which converts the optical signal to an electrical pulse. The electrical pulses from all pulse timing receivers are fed through an OR circuit to start a time interval measuring device and each electrical pulse is used to stop an individual channel in the measuring device thereby recording the firing sequence of the multi-stage pulse generator.
Prefire identification for pulse power systems
Longmire, Jerry L.; Thuot, Michael E.; Warren, David S.
1985-01-01
Prefires in a high-power, high-frequency, multi-stage pulse generator are detected by a system having an EMI shielded pulse timing transmitter associated with and tailored to each stage of the pulse generator. Each pulse timing transmitter upon detection of a pulse triggers a laser diode to send an optical signal through a high frequency fiber optic cable to a pulse timing receiver which converts the optical signal to an electrical pulse. The electrical pulses from all pulse timing receivers are fed through an OR circuit to start a time interval measuring device and each electrical pulse is used to stop an individual channel in the measuring device thereby recording the firing sequence of the multi-stage pulse generator.
Cationic peptide exposure enhances pulsed-electric-field-mediated membrane disruption.
Kennedy, Stephen M; Aiken, Erik J; Beres, Kaytlyn A; Hahn, Adam R; Kamin, Samantha J; Hagness, Susan C; Booske, John H; Murphy, William L
2014-01-01
The use of pulsed electric fields (PEFs) to irreversibly electroporate cells is a promising approach for destroying undesirable cells. This approach may gain enhanced applicability if the intensity of the PEF required to electrically disrupt cell membranes can be reduced via exposure to a molecular deliverable. This will be particularly impactful if that reduced PEF minimally influences cells that are not exposed to the deliverable. We hypothesized that the introduction of charged molecules to the cell surfaces would create regions of enhanced transmembrane electric potential in the vicinity of each charged molecule, thereby lowering the PEF intensity required to disrupt the plasma membranes. This study will therefore examine if exposure to cationic peptides can enhance a PEF's ability to disrupt plasma membranes. We exposed leukemia cells to 40 μs PEFs in media containing varying concentrations of a cationic peptide, polyarginine. We observed the internalization of a membrane integrity indicator, propidium iodide (PI), in real time. Based on an individual cell's PI fluorescence versus time signature, we were able to determine the relative degree of membrane disruption. When using 1-2 kV/cm, exposure to >50 μg/ml of polyarginine resulted in immediate and high levels of PI uptake, indicating severe membrane disruption, whereas in the absence of peptide, cells predominantly exhibited signatures indicative of no membrane disruption. Additionally, PI entered cells through the anode-facing membrane when exposed to cationic peptide, which was theoretically expected. Exposure to cationic peptides reduced the PEF intensity required to induce rapid and irreversible membrane disruption. Critically, peptide exposure reduced the PEF intensities required to elicit irreversible membrane disruption at normally sub-electroporation intensities. We believe that these cationic peptides, when coupled with current advancements in cell targeting techniques will be useful tools in applications where targeted destruction of unwanted cell populations is desired.
Cationic Peptide Exposure Enhances Pulsed-Electric-Field-Mediated Membrane Disruption
Kennedy, Stephen M.; Aiken, Erik J.; Beres, Kaytlyn A.; Hahn, Adam R.; Kamin, Samantha J.; Hagness, Susan C.; Booske, John H.; Murphy, William L.
2014-01-01
Background The use of pulsed electric fields (PEFs) to irreversibly electroporate cells is a promising approach for destroying undesirable cells. This approach may gain enhanced applicability if the intensity of the PEF required to electrically disrupt cell membranes can be reduced via exposure to a molecular deliverable. This will be particularly impactful if that reduced PEF minimally influences cells that are not exposed to the deliverable. We hypothesized that the introduction of charged molecules to the cell surfaces would create regions of enhanced transmembrane electric potential in the vicinity of each charged molecule, thereby lowering the PEF intensity required to disrupt the plasma membranes. This study will therefore examine if exposure to cationic peptides can enhance a PEF’s ability to disrupt plasma membranes. Methodology/Principal Findings We exposed leukemia cells to 40 μs PEFs in media containing varying concentrations of a cationic peptide, polyarginine. We observed the internalization of a membrane integrity indicator, propidium iodide (PI), in real time. Based on an individual cell’s PI fluorescence versus time signature, we were able to determine the relative degree of membrane disruption. When using 1–2 kV/cm, exposure to >50 μg/ml of polyarginine resulted in immediate and high levels of PI uptake, indicating severe membrane disruption, whereas in the absence of peptide, cells predominantly exhibited signatures indicative of no membrane disruption. Additionally, PI entered cells through the anode-facing membrane when exposed to cationic peptide, which was theoretically expected. Conclusions/Significance Exposure to cationic peptides reduced the PEF intensity required to induce rapid and irreversible membrane disruption. Critically, peptide exposure reduced the PEF intensities required to elicit irreversible membrane disruption at normally sub-electroporation intensities. We believe that these cationic peptides, when coupled with current advancements in cell targeting techniques will be useful tools in applications where targeted destruction of unwanted cell populations is desired. PMID:24671150
Embedded intelligent adaptive PI controller for an electromechanical system.
El-Nagar, Ahmad M
2016-09-01
In this study, an intelligent adaptive controller approach using the interval type-2 fuzzy neural network (IT2FNN) is presented. The proposed controller consists of a lower level proportional - integral (PI) controller, which is the main controller and an upper level IT2FNN which tuning on-line the parameters of a PI controller. The proposed adaptive PI controller based on IT2FNN (API-IT2FNN) is implemented practically using the Arduino DUE kit for controlling the speed of a nonlinear DC motor-generator system. The parameters of the IT2FNN are tuned on-line using back-propagation algorithm. The Lyapunov theorem is used to derive the stability and convergence of the IT2FNN. The obtained experimental results, which are compared with other controllers, demonstrate that the proposed API-IT2FNN is able to improve the system response over a wide range of system uncertainties. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.
Effect of posture on arterial baroreflex control of heart rate in humans
NASA Technical Reports Server (NTRS)
Harrison, M. H.; Rittenhouse, D.; Greenleaf, J. E.
1986-01-01
The effects of blood-volume redistribution induced by postural changes on baroreflex activity are investigated. The central blood volume and baroreceptor functions of ten males between 23-51 years old were examined while they were in the head-up tilt (HUT), head-down tilt (HDT), and supine positions. It is observed that during HDT at 15 deg the pulse interval over the first five cardiac cycles following neck suction onset is 51 + or - 18 ms longer, at 30 deg it is 61 + or - 20 ms longer, and at 45 deg it is 74 + or - 35 ms longer than at supine; during HUT at 15 deg the pulse interval is 25 + or - 9 ms shorter than when supine, but for the 30 and 45 deg there is no significant difference in pulse interval detected. The data reveal that posture does modify arterial baroreflex control of heart rate.
Absorption of subcutaneously infused insulin: influence of the basal rate pulse interval.
Hildebrandt, P; Birch, K; Jensen, B M; Kühl, C; Brange, J
1985-01-01
Eight insulin-dependent diabetic patients were given two constant infusions (each 1 IU/h) of 125I-labeled insulin into the abdominal subcutaneous tissue for about 12 h. Insulin was infused in pulses into one side of the abdomen in 6-min intervals (by means of an Auto-Syringe pump) and in the other side of the abdomen, insulin was infused in 1-h intervals (by means of a Medix pump). The size of the subcutaneous depots was continuously measured by counting the radioactivity at the infusion sites. After starting the infusions, the two depots were built up to steady-state levels at the same time and of the same size (approximately 3 IU) and with similar absorption rates. Thus, during basal rate insulin infusion, identical insulin absorption kinetics was achieved, irrespective of a 10-fold difference in the pulse rate.
NASA Astrophysics Data System (ADS)
Davis, C. R.; Snyder, R. W.; Egitto, F. D.; D'Couto, G. C.; Babu, S. V.
1994-09-01
Single-photon excimer laser ablation of neat poly(tetrafluoroethylene) (PTFE) is not observed at emissions in the 'quartz' UV, i.e., from about 190-380 nm. However, it has been successfully demonstrated that, when the fluoropolymer is doped with small quantities of polyimide (PI), ablation in the quartz UV, e.g., at 248 and 308 nm and pulse widths of about 25 ns, is readily achieved. When PI-PTFE blends are exposed to subthreshold fluences, considerable changes in surface topography occur although clearly defined structures, e.g., pits, are not formed. Using photoacoustic infrared spectroscopy to evaluate surface and bulk chemical changes to blends exposed to subthreshold excimer laser fluences, is less than 100 mJ/sq cm, it is shown that PI (1) is distributed throughout the bulk and resides at the surface and (2) is selectively absorbing the high-energy photons and as a result being preferentially removed from the surface.
NASA Astrophysics Data System (ADS)
Huvanandana, Jacqueline; Nguyen, Chinh; Thamrin, Cindy; Tracy, Mark; Hinder, Murray; McEwan, Alistair L.
2017-04-01
Despite the decline in mortality rates of extremely preterm infants, intraventricular haemorrhage (IVH) remains common in survivors. The need for resuscitation and cardiorespiratory management, particularly within the first 24 hours of life, are important factors in the incidence and timing of IVH. Variability analyses of heart rate and blood pressure data has demonstrated potential approaches to predictive monitoring. In this study, we investigated the early identification of infants at a high risk of developing IVH, using time series analysis of blood pressure and respiratory data. We also explore approaches to improving model performance, such as the inclusion of multiple variables and signal pre-processing to enhance the results from detrended fluctuation analysis. Of the models we evaluated, the highest area under receiver-operator characteristic curve (5th, 95th percentile) achieved was 0.921 (0.82, 1.00) by mean diastolic blood pressure and the long-term scaling exponent of pulse interval (PI α2), exhibiting a sensitivity of >90% at a specificity of 75%. Following evaluation in a larger population, our approach may be useful in predictive monitoring to identify infants at high risk of developing IVH, offering caregivers more time to adjust intensive care treatment.
Liu, Datong; Peng, Yu; Peng, Xiyuan
2018-01-01
Effective anomaly detection of sensing data is essential for identifying potential system failures. Because they require no prior knowledge or accumulated labels, and provide uncertainty presentation, the probability prediction methods (e.g., Gaussian process regression (GPR) and relevance vector machine (RVM)) are especially adaptable to perform anomaly detection for sensing series. Generally, one key parameter of prediction models is coverage probability (CP), which controls the judging threshold of the testing sample and is generally set to a default value (e.g., 90% or 95%). There are few criteria to determine the optimal CP for anomaly detection. Therefore, this paper designs a graphic indicator of the receiver operating characteristic curve of prediction interval (ROC-PI) based on the definition of the ROC curve which can depict the trade-off between the PI width and PI coverage probability across a series of cut-off points. Furthermore, the Youden index is modified to assess the performance of different CPs, by the minimization of which the optimal CP is derived by the simulated annealing (SA) algorithm. Experiments conducted on two simulation datasets demonstrate the validity of the proposed method. Especially, an actual case study on sensing series from an on-orbit satellite illustrates its significant performance in practical application. PMID:29587372
X-ray microanalysis of rotavirus-infected mouse intestine: A new concept of diarrhoeal secretion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spencer, A.J.; Osborne, M.P.; Haddon, S.J.
1990-05-01
Neonatal mice were infected at 7 days of age with rotavirus (epizootic diarrhea of infant mice (EDIM) virus) and killed at 24-h intervals postinfection (PI). Cytoplasmic concentrations of Na, Mg, P, S, Cl, K, and Ca intestinal epithelial cells from infected and age-matched control animals were measured by x-ray microanalysis. In villus tip cells, Ca concentration increased at 24-96 h PI; Na concentration increased at 24-72 h PI; Ca and Na concentrations were near normal by 168 h PI. K concentration decreased 24-72 h PI, and Cl concentration decreased 48-96 h PI. In crypt cells, changes were observed without amore » discernible pattern: at 96 h PI, Na, Mg, S, and Cl concentrations increased and K concentration decreased; at 120 h PI, the concentrations of all elements except Na and Ca increased. In villus base cells, the mean concentrations of all elements except Ca peaked at 48-72 h PI and at 120 h PI. Na and Cl concentrations increased dramatically in some cells from 48 h PI onward. All the above concentration values were obtained from freeze-dried specimens and expressed in millimoles per kilogram of dry weight. Conversion of a limited number of data, pertaining to villus base cells, from dry weight to wet weight was possible. This conversion revealed that villus base cells in infected animals were more hydrated than corresponding cells from control animals. Also, the Na and Cl concentrations in mmol/kg H2O were significantly higher in villus base cells from infected animals than in those from corresponding controls: 137 +/- 7 versus 38 +/- 4 (Na) and 121 +/- 5 versus 89 +/- 6 (Cl). Wet weight concentrations of other elements were either the same (Mg) or lower (P, S, and K) after infection with virus.« less
Time-of-flight direct recoil ion scattering spectrometer
Krauss, Alan R.; Gruen, Dieter M.; Lamich, George J.
1994-01-01
A time of flight direct recoil and ion scattering spectrometer beam line (10). The beam line (10) includes an ion source (12) which injects ions into pulse deflection regions (14) and (16) separated by a drift space (18). A final optics stage includes an ion lens and deflection plate assembly (22). The ion pulse length and pulse interval are determined by computerized adjustment of the timing between the voltage pulses applied to the pulsed deflection regions (14) and (16).
Hybrid Physical Vapor Deposition Instrument for Advanced Functional Multilayers and Materials
2016-04-27
Hybrid Physical Vapor Deposition Instrument for Advanced Functional Multilayers and Materials PI Maria received support to construct a physical...vapor deposition (PVD) system that combines electron beam (e- beam) evaporation, magnetron sputtering, pulsed laser ablation, and ion-assisted deposition ...The instrumentation enables clean, uniform, and rapid deposition of a wide variety of metallic, semiconducting, and ceramic thin films with
Hybrid Physical Vapor Deposition Instrument for Advanced Functional Multilayers and Materials
2016-04-27
Hybrid Physical Vapor Deposition Instrument for Advanced Functional Multilayers and Materials PI Maria received support to construct a physical... vapor deposition (PVD) system that combines electron beam (e- beam) evaporation, magnetron sputtering, pulsed laser ablation, and ion-assisted deposition ...peer-reviewed journals: Number of Papers published in non peer-reviewed journals: Final Report: Hybrid Physical Vapor Deposition Instrument for Advanced
NASA Astrophysics Data System (ADS)
Ajay Kumar, M.; Srikanth, N. V.
2014-03-01
In HVDC Light transmission systems, converter control is one of the major fields of present day research works. In this paper, fuzzy logic controller is utilized for controlling both the converters of the space vector pulse width modulation (SVPWM) based HVDC Light transmission systems. Due to its complexity in the rule base formation, an intelligent controller known as adaptive neuro fuzzy inference system (ANFIS) controller is also introduced in this paper. The proposed ANFIS controller changes the PI gains automatically for different operating conditions. A hybrid learning method which combines and exploits the best features of both the back propagation algorithm and least square estimation method is used to train the 5-layer ANFIS controller. The performance of the proposed ANFIS controller is compared and validated with the fuzzy logic controller and also with the fixed gain conventional PI controller. The simulations are carried out in the MATLAB/SIMULINK environment. The results reveal that the proposed ANFIS controller is reducing power fluctuations at both the converters. It also improves the dynamic performance of the test power system effectively when tested for various ac fault conditions.
Item-nonspecific proactive interference in monkeys' auditory short-term memory.
Bigelow, James; Poremba, Amy
2015-09-01
Recent studies using the delayed matching-to-sample (DMS) paradigm indicate that monkeys' auditory short-term memory (STM) is susceptible to proactive interference (PI). During the task, subjects must indicate whether sample and test sounds separated by a retention interval are identical (match) or not (nonmatch). If a nonmatching test stimulus also occurred on a previous trial, monkeys are more likely to incorrectly make a "match" response (item-specific PI). However, it is not known whether PI may be caused by sounds presented on prior trials that are similar, but nonidentical to the current test stimulus (item-nonspecific PI). This possibility was investigated in two experiments. In Experiment 1, memoranda for each trial comprised tones with a wide range of frequencies, thus minimizing item-specific PI and producing a range of frequency differences among nonidentical tones. In Experiment 2, memoranda were drawn from a set of eight artificial sounds that differed from each other by one, two, or three acoustic dimensions (frequency, spectral bandwidth, and temporal dynamics). Results from both experiments indicate that subjects committed more errors when previously-presented sounds were acoustically similar (though not identical) to the test stimulus of the current trial. Significant effects were produced only by stimuli from the immediately previous trial, suggesting that item-nonspecific PI is less perseverant than item-specific PI, which can extend across noncontiguous trials. Our results contribute to existing human and animal STM literature reporting item-nonspecific PI caused by perceptual similarity among memoranda. Together, these observations underscore the significance of both temporal and discriminability factors in monkeys' STM. Copyright © 2015 Elsevier B.V. All rights reserved.
Galvis-Ovallos, Fredy; da Silva, Mariana Dantas; Bispo, Giulia Baldaconi da Silva; de Oliveira, Alessandra Gutierrez; Neto, José Rodriguez Gonçalves; Malafronte, Rosely dos Santos; Galati, Eunice Aparecida Bianchi
2017-01-01
American visceral leishmaniasis is a zoonosis caused by Leishmania infantum and transmitted mainly by Lutzomyia longipalpis. However, canine cases have been reported in the absence of this species in the Greater São Paulo region, where Pintomyia fischeri and Migonemyia migonei are the predominant species. This raises the suspicion that they could be acting as vectors. Therefore, this study sought to investigate specific vector capacity parameters of these species and to compare them with those of Lu. longipalpis s.l. Among these parameters the blood feeding rate, the survival, and the susceptibility to the development of Le. infantum were evaluated for the three species, and the attractiveness of dogs to Pi. fischeri and Mg. migonei was evaluated. The estimated interval between blood meals was shorter for Lu. longipalpis s.l, followed by Pi. fischeri and Mg. migonei. The infection rate with Le. infantum flagellates in Lu. longipalpis was 9.8%, in Pi. fischeri 4.8%, and in Mg. migonei nil. The respective infective life expectancies (days) of Lu. longipalpis, Mg. migonei, and Pi. fischeri were 2.4, 1.94, and 1.68. Both Pi. fischeri and Mg. migonei were captured in the kennel with a predominance (95%) of Pi. fischeri. Considering the great attractiveness of dogs to Pi. fischeri, its susceptibility to infection by Le. infantum, infective life expectancies, and predominance in Greater São Paulo, this study presents evidence of Pi. fischeri as a potential vector of this parasite in the region. PMID:28134092
Dual-pulses and harmonic patterns of a square-wave soliton in passively mode-locked fiber laser
NASA Astrophysics Data System (ADS)
Ma, Wanzhuo; Wang, Tianshu; Su, Qingchao; Zhang, Jing; Jia, Qingsong; Jiang, Huilin
2018-06-01
We demonstrate a square-wave soliton pulse passively mode-locked fiber laser. The mode-locked pulses are achieved by using a nonlinear amplifying loop mirror. Single-pulse operation at a fundamental repetition rate of 3.2 MHz is obtained. The optical spectrum presents the soliton feature of several sidebands. The pulse duration expands with increasing pump power, but the amplitude hardly varies. Pulse breaking occurs and a stable dual-pulse is obtained with a fixed interval of 48 ns. Harmonic mode-locked states can be achieved when the total pump power is higher than 740 mW. The harmonic pulses can also operate in both single-pulse and dual-pulse states.
Structure and Utility of Blind Speed Intervals Associated with Doppler Measurements of Range Rate
1993-02-01
computer programming concepts of speed, memory , and data structures that can be exploited to fabricate efficient software realizations of two phase range...to the effect that it is possible to derive a reasonable unambiguous estimate of range rate from the measurement of the pulse-to-pulse phase shift in...the properties of the blind speed intervals generated by the base speeds involved in two measurement equations. Sections 12 through 18 make up the
Measuring Differential Delays With Sine-Squared Pulses
NASA Technical Reports Server (NTRS)
Hurst, Robert N.
1994-01-01
Technique for measuring differential delays among red, green, and blue components of video signal transmitted on different parallel channels exploits sine-squared pulses that are parts of standard test signals transmitted during vertical blanking interval of frame period. Technique does not entail expense of test-signal generator. Also applicable to nonvideo signals including sine-squared pulses.
Kastelein, Ronald A; Hoek, Lean; Gransier, Robin; Rambags, Martijn; Claeys, Naomi
2014-07-01
Safety criteria for underwater low-frequency active sonar sounds produced during naval exercises are needed to protect harbor porpoise hearing. As a first step toward defining criteria, a porpoise was exposed to sequences consisting of series of 1-s, 1-2 kHz sonar down-sweeps without harmonics (as fatiguing noise) at various combinations of average received sound pressure levels (SPLs; 144-179 dB re 1 μPa), exposure durations (1.9-240 min), and duty cycles (5%-100%). Hearing thresholds were determined for a narrow-band frequency-swept sine wave centered at 1.5 kHz before exposure to the fatiguing noise, and at 1-4, 4-8, 8-12, 48, 96, 144, and 1400 min after exposure, to quantify temporary threshold shifts (TTSs) and recovery of hearing. Results show that the inter-pulse interval of the fatiguing noise is an important parameter in determining the magnitude of noise-induced TTS. For the reported range of exposure combinations (duration and SPL), the energy of the exposure (i.e., cumulative sound exposure level; SELcum) can be used to predict the induced TTS, if the inter-pulse interval is known. Exposures with equal SELcum but with different inter-pulse intervals do not result in the same induced TTS.
Thompson, P O; Findley, L T; Vidal, O
1992-12-01
Low-frequency vocalizations were recorded from fin whales, Balaenoptera physalus, in the Gulf of California, Mexico, during three cruises. In March 1985, recorded 20-Hz pulses were in sequences of regular 9-s interpulse intervals. In August 1987, nearly all were in sequences of doublets with alternating 5- and 18-s interpulse intervals. No 20-Hz pulse sequences of any kind were detected in February 1987. The typical pulse modulated from 42 to 20 Hz and its median duration was 0.7 s (1985 data). Most other fin whale sounds were also short tonal pulses averaging 82, 56, and 68 Hz, respectively, for the three cruises; 89% were modulated in frequency, mostly downward. Compared to Atlantic and Pacific Ocean regions, Gulf of California 20-Hz pulses were unique in terms of frequency modulation, interpulse sound levels, and temporal patterns. Fin whales in the Gulf may represent a regional stock revealed by their sound characteristics, a phenomenon previously shown for humpback whales, birds, and fish. Regional differences in fin whale sounds were found in comparisons of Atlantic and Pacific locations.
NASA Technical Reports Server (NTRS)
Orwig, L. E.
1971-01-01
Data from a balloon flight experiment using an Na I scintillation spectrometer were analyzed for gamma ray pulsation. The payload was carried to a nominal atmospheric depth of 3.5 g/cm2. A superposed epoch analysis was performed on a 12,000 second portion of the data spanning a total time interval of 16,700 seconds at float altitude. A positive pulsed contribution was observed at the expected apparent frequency of NP 0532 having the typical double pulse structure. The results indicate a time-averaged pulse photon flux of 0.00144 + or - 0.00057 photons/sq cm/sec in the energy interval from 250 keV to 2.3 MeV. This represents a time-averaged pulsed power of 0.000649 + or - 0.000257 keV/sq cm/sec/keV. The ratio of interpulse to main pulse was found to be 2.4 + or - 1.9. The analysis indicates a positive photon flux from 250 keV to 725 keV of 0.00120 + or - 0.00052 photons/sq cm/sec.
Virtual active touch using randomly patterned intracortical microstimulation.
O'Doherty, Joseph E; Lebedev, Mikhail A; Li, Zheng; Nicolelis, Miguel A L
2012-01-01
Intracortical microstimulation (ICMS) has promise as a means for delivering somatosensory feedback in neuroprosthetic systems. Various tactile sensations could be encoded by temporal, spatial, or spatiotemporal patterns of ICMS. However, the applicability of temporal patterns of ICMS to artificial tactile sensation during active exploration is unknown, as is the minimum discriminable difference between temporally modulated ICMS patterns. We trained rhesus monkeys in an active exploration task in which they discriminated periodic pulse-trains of ICMS (200 Hz bursts at a 10 Hz secondary frequency) from pulse trains with the same average pulse rate, but distorted periodicity (200 Hz bursts at a variable instantaneous secondary frequency). The statistics of the aperiodic pulse trains were drawn from a gamma distribution with mean inter-burst intervals equal to those of the periodic pulse trains. The monkeys distinguished periodic pulse trains from aperiodic pulse trains with coefficients of variation 0.25 or greater. Reconstruction of movement kinematics, extracted from the activity of neuronal populations recorded in the sensorimotor cortex concurrent with the delivery of ICMS feedback, improved when the recording intervals affected by ICMS artifacts were removed from analysis. These results add to the growing evidence that temporally patterned ICMS can be used to simulate a tactile sense for neuroprosthetic devices.
Does proactive interference play a significant role in visual working memory tasks?
Makovski, Tal
2016-10-01
Visual working memory (VWM) is an online memory buffer that is typically assumed to be immune to source memory confusions. Accordingly, the few studies that have investigated the role of proactive interference (PI) in VWM tasks found only a modest PI effect at best. In contrast, a recent study has found a substantial PI effect in that performance in a VWM task was markedly improved when all memory items were unique compared to the more standard condition in which only a limited set of objects was used. The goal of the present study was to reconcile this discrepancy between the findings, and to scrutinize the extent to which PI is involved in VWM tasks. Experiments 1-2 showed that the robust advantage in using unique memory items can also be found in a within-subject design and is largely independent of set size, encoding duration, or intertrial interval. Importantly, however, PI was found mainly when all items were presented at the same location, and the effect was greatly diminished when the items were presented, either simultaneously (Experiment 3) or sequentially (Experiments 4-5), at distinct locations. These results indicate that PI is spatially specific and that without the assistance of spatial information VWM is not protected from PI. Thus, these findings imply that spatial information plays a key role in VWM, and underscore the notion that VWM is more vulnerable to interference than is typically assumed. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
[Design of MC-III low frequency pulsed strong magnetic fields generator].
Wen, Jun; Zhong, Lisheng; Xie, Hengkun; Qu, Xuemin; Ju, Hongbo; Yang, Jiqing; Wang, Sigang
2002-12-01
In this paper, We designed and accomplished a low frequency pulsed strong magnetic fields generator, which provides a pulsed magnetic field with the intensity range from 0.1-2.5 T and the adjusted time interval of pulse. This device is easy to operate and performs reliably. It can work steady for a long time and has been successful used in the experiments of biological effects of electromagnetics.
Guan, Shane; Vignola, Joseph; Judge, John; Turo, Diego
2015-12-01
Offshore oil and gas exploration using seismic airguns generates intense underwater pulses that could cause marine mammal hearing impairment and/or behavioral disturbances. However, few studies have investigated the resulting multipath propagation and reverberation from airgun pulses. This research uses continuous acoustic recordings collected in the Arctic during a low-level open-water shallow marine seismic survey, to measure noise levels between airgun pulses. Two methods were used to quantify noise levels during these inter-pulse intervals. The first, based on calculating the root-mean-square sound pressure level in various sub-intervals, is referred to as the increment computation method, and the second, which employs the Hilbert transform to calculate instantaneous acoustic amplitudes, is referred to as the Hilbert transform method. Analyses using both methods yield similar results, showing that the inter-pulse sound field exceeds ambient noise levels by as much as 9 dB during relatively quiet conditions. Inter-pulse noise levels are also related to the source distance, probably due to the higher reverberant conditions of the very shallow water environment. These methods can be used to quantify acoustic environment impacts from anthropogenic transient noises (e.g., seismic pulses, impact pile driving, and sonar pings) and to address potential acoustic masking affecting marine mammals.
Migration of cell surface concanavalin A receptors in pulsed electric fields.
Lin-Liu, S; Adey, W R; Poo, M M
1984-01-01
Concanavalin A (con A) receptors on the surface of cultured Xenopus myoblasts redistributed in response to monopolar, pulsed electric fields. The prefield uniform distribution of the receptors became asymmetrical, and was polarized toward the cathodal pole, in the same way as in DC fields. The extent of asymmetry depended on the duration of field exposure, pulse width (or alternatively, interpulse interval), frequency, and intensity. This relationship was most conveniently expressed by using duty cycle, a quantity determined by both pulse width and frequency. Pulses of average intensity 1.5 V/cm induced detectable asymmetry within 5 min. At the lowest average field intensity used, 0.8 V/cm, significant asymmetry was detected at 150 min. For pulses of high duty cycle (greater than 25%), steady state was reached after 30 min exposure and the steady state asymmetry was dependent on average field intensity. For low duty cycle fields, the time required to reach steady state was prolonged (greater than 50 min). Before reaching a steady state, effectiveness of the pulses, as compared with DC fields of equivalent intensity, was a function of duty cycle. A low duty cycle field (fixed number of pulses at low frequency or long interpulse interval) was less effective than high duty cycle fields or DC. PMID:6743751
Pulsed helium ionization detection system
Ramsey, R.S.; Todd, R.A.
1985-04-09
A helium ionization detection system is provided which produces stable operation of a conventional helium ionization detector while providing improved sensitivity and linearity. Stability is improved by applying pulsed dc supply voltage across the ionization detector, thereby modifying the sampling of the detectors output current. A unique pulse generator is used to supply pulsed dc to the detector which has variable width and interval adjust features that allows up to 500 V to be applied in pulse widths ranging from about 150 nsec to about dc conditions.
Pulsed helium ionization detection system
Ramsey, Roswitha S.; Todd, Richard A.
1987-01-01
A helium ionization detection system is provided which produces stable operation of a conventional helium ionization detector while providing improved sensitivity and linearity. Stability is improved by applying pulsed dc supply voltage across the ionization detector, thereby modifying the sampling of the detectors output current. A unique pulse generator is used to supply pulsed dc to the detector which has variable width and interval adjust features that allows up to 500 V to be applied in pulse widths ranging from about 150 nsec to about dc conditions.
Sleep-related memory consolidation in primary insomnia.
Nissen, Christoph; Kloepfer, Corinna; Feige, Bernd; Piosczyk, Hannah; Spiegelhalder, Kai; Voderholzer, Ulrich; Riemann, Dieter
2011-03-01
It has been suggested that healthy sleep facilitates the consolidation of newly acquired memories and underlying brain plasticity. The authors tested the hypothesis that patients with primary insomnia (PI) would show deficits in sleep-related memory consolidation compared to good sleeper controls (GSC). The study used a four-group parallel design (n=86) to investigate the effects of 12 h of night-time, including polysomnographically monitored sleep ('sleep condition' in PI and GSC), versus 12 h of daytime wakefulness ('wake condition' in PI and GSC) on procedural (mirror tracing task) and declarative memory consolidation (visual and verbal learning task). Demographic characteristics and memory encoding did not differ between the groups at baseline. Polysomnography revealed a significantly disturbed sleep profile in PI compared to GSC in the sleep condition. Night-time periods including sleep in GSC were associated with (i) a significantly enhanced procedural and declarative verbal memory consolidation compared to equal periods of daytime wakefulness in GSC and (ii) a significantly enhanced procedural memory consolidation compared to equal periods of daytime wakefulness and night-time sleep in PI. Across retention intervals of daytime wakefulness, no differences between the experimental groups were observed. This pattern of results suggests that healthy sleep fosters the consolidation of new memories, and that this process is impaired for procedural memories in patients with PI. Future work is needed to investigate the impact of treatment on improving sleep and memory. © 2010 European Sleep Research Society.
Modelling and regulating of cardio-respiratory response for the enhancement of interval training
2014-01-01
Background The interval training method has been a well known exercise protocol which helps strengthen and improve one’s cardiovascular fitness. Purpose To develop an effective training protocol to improve cardiovascular fitness based on modelling and analysis of Heart Rate (HR) and Oxygen Uptake (VO2) dynamics. Methods In order to model the cardiorespiratory response to the onset and offset exercises, the (K4b2, Cosmed) gas analyzer was used to monitor and record the heart rate and oxygen uptake for ten healthy male subjects. An interval training protocol was developed for young health users and was simulated using a proposed RC switching model which was presented to accommodate the variations of the cardiorespiratory dynamics to running exercises. A hybrid system model was presented to describe the adaptation process and a multi-loop PI control scheme was designed for the tuning of interval training regime. Results By observing the original data for each subject, we can clearly identify that all subjects have similar HR and VO2 profiles. The proposed model is capable to simulate the exercise responses during onset and offset exercises; it ensures the continuity of the outputs within the interval training protocol. Under some mild assumptions, a hybrid system model can describe the adaption process and accordingly a multi-loop PI controller can be designed for the tuning of interval training protocol. The self-adaption feature of the proposed controller gives the exerciser the opportunity to reach his desired setpoints after a certain number of training sessions. Conclusions The established interval training protocol targets a range of 70-80% of HRmax which is mainly a training zone for the purpose of cardiovascular system development and improvement. Furthermore, the proposed multi-loop feedback controller has the potential to tune the interval training protocol according to the feedback from an individual exerciser. PMID:24499131
Variable-pulse switching circuit accurately controls solenoid-valve actuations
NASA Technical Reports Server (NTRS)
Gillett, J. D.
1967-01-01
Solid state circuit generating adjustable square wave pulses of sufficient power operates a 28 volt dc solenoid valve at precise time intervals. This circuit is used for precise time control of fluid flow in combustion experiments.
VERNIER CHRONOTRON UTILIZING AT LEAST TWO SHORTED DELAY LINES
Rufer, R.P.
1964-02-25
An improved vernier chronotron featuring pulse-forming circuits of a ringing'' or back and forth'' oscillatory type is described. A delay line shorted at both ends together with transistor circuitry to introduce a pulse into that line and also to provide reinforcement of the pulse as it oscillates between the pulse-reflective extremities is provided. A transistorized coincidence circuit is also provided. Enhanced measurement of time intervals in the nanosecond range is afforded. (AEC)
Biologically Inspired Waveform Diversity for Synthetic Autonomous Navigation Sensing
2009-11-01
Pulse interval and repetition rate When searching for prey, bats often emit one pulse per wing beat . This is because the mechanics of flapping the...wings, breathing, and producing sound pulses are all coupled. Because of this coupling, the pulse repetition rate is often the same as wing beat ...give accurate measures of delay and hence range [26]. For determination of direction, the horizontal angle of a target is determined from binaural
von Wowern, Emma; Olofsson, Per
2018-09-01
Dark chocolate has shown beneficial effects on cardiovascular health and might also modulate hypertensive complications in pregnancy and uteroplacental blood flow. Increased uteroplacental resistance is associated with systemic arterial stiffness. We aimed to investigate the short-term effect of flavonoid-rich chocolate on arterial stiffness and Doppler blood flow velocimetry indexes in pregnant women with compromised uteroplacental blood flow. Doppler blood flow velocimetry and digital pulse wave analysis (DPA) were performed in 25 women pregnant in the second and third trimesters with uterine artery (UtA) score (UAS) 3-4, before and after 3 days of ingestion of chocolate with high flavonoid and antioxidant contents. UtA pulsatility index (PI), UtA diastolic notching, UAS (semiquantitative measure of PI and notching combined), and umbilical artery PI were calculated, and DPA variables representing central and peripheral maternal arteries were recorded. Mean UtA PI (p = .049) and UAS (p = .025) significantly decreased after chocolate consumption. There were no significant changes in UtA diastolic notching or any DPA indexes of arterial stiffness/vascular tone. Chocolate may have beneficial effects on the uteroplacental circulation, but in this pilot study, we could not demonstrate effects on arterial vascular tone as assessed by DPA.
Imel, Erik A.; Ruppe, Mary D.; Weber, Thomas J.; Klausner, Mark A.; Ito, Takahiro; Vergeire, Maria; Humphrey, Jeffrey; Glorieux, Francis H.; Portale, Anthony A.; Insogna, Karl; Carpenter, Thomas O.; Peacock, Munro
2015-01-01
Abstract In X‐linked hypophosphatemia (XLH), serum fibroblast growth factor 23 (FGF23) is increased and results in reduced renal maximum threshold for phosphate reabsorption (TmP), reduced serum inorganic phosphorus (Pi), and inappropriately low normal serum 1,25 dihydroxyvitamin D (1,25[OH]2D) concentration, with subsequent development of rickets or osteomalacia. KRN23 is a recombinant human IgG1 monoclonal antibody that binds to FGF23 and blocks its activity. Up to 4 doses of KRN23 were administered subcutaneously every 28 days to 28 adults with XLH. Mean ± standard deviation KRN23 doses administered were 0.05, 0.10 ± 0.01, 0.28 ± 0.06, and 0.48 ± 0.16 mg/kg. The mean time to reach maximum serum KRN23 levels was 7.0 to 8.5 days. The mean KRN23 half‐life was 16.4 days. The mean area under the concentration–time curve (AUCn) for each dosing interval increased proportionally with increases in KRN23 dose. The mean intersubject variability in AUCn ranged from 30% to 37%. The area under the effect concentration–time curve (AUECn) for change from baseline in TmP per glomerular filtration rate, serum Pi, 1,25(OH)2D, and bone markers for each dosing interval increased linearly with increases in KRN23 AUCn. Linear correlation between serum KRN23 concentrations and increase in serum Pi support KRN23 dose adjustments based on predose serum Pi concentration. © 2015 The Authors. The Journal of Clinical Pharmacology Published by Wiley Periodicals, Inc. on behalf of American College of Clinical Pharmacology PMID:26073451
Wade, E.J.
1958-07-29
An apparatus is described for counting and recording the number of electrical pulses occurring in each of a timed sequence of groups of pulses. The particular feature of the invention resides in a novel timing circuit of the univibrator type which provides very accurately timed pulses for opening each of a series of coincidence channels in sequence. The univibrator is shown incorporated in a pulse analyzing system wherein a series of pulse counting channels are periodically opened in order, one at a time, for a predetermtned open time interval, so that only one channel will be open at the time of occurrence of any of the electrical pulses to be sorted.
A Quantitative Analysis of Pulsed Signals Emitted by Wild Bottlenose Dolphins.
Luís, Ana Rita; Couchinho, Miguel N; Dos Santos, Manuel E
2016-01-01
Common bottlenose dolphins (Tursiops truncatus), produce a wide variety of vocal emissions for communication and echolocation, of which the pulsed repertoire has been the most difficult to categorize. Packets of high repetition, broadband pulses are still largely reported under a general designation of burst-pulses, and traditional attempts to classify these emissions rely mainly in their aural characteristics and in graphical aspects of spectrograms. Here, we present a quantitative analysis of pulsed signals emitted by wild bottlenose dolphins, in the Sado estuary, Portugal (2011-2014), and test the reliability of a traditional classification approach. Acoustic parameters (minimum frequency, maximum frequency, peak frequency, duration, repetition rate and inter-click-interval) were extracted from 930 pulsed signals, previously categorized using a traditional approach. Discriminant function analysis revealed a high reliability of the traditional classification approach (93.5% of pulsed signals were consistently assigned to their aurally based categories). According to the discriminant function analysis (Wilk's Λ = 0.11, F3, 2.41 = 282.75, P < 0.001), repetition rate is the feature that best enables the discrimination of different pulsed signals (structure coefficient = 0.98). Classification using hierarchical cluster analysis led to a similar categorization pattern: two main signal types with distinct magnitudes of repetition rate were clustered into five groups. The pulsed signals, here described, present significant differences in their time-frequency features, especially repetition rate (P < 0.001), inter-click-interval (P < 0.001) and duration (P < 0.001). We document the occurrence of a distinct signal type-short burst-pulses, and highlight the existence of a diverse repertoire of pulsed vocalizations emitted in graded sequences. The use of quantitative analysis of pulsed signals is essential to improve classifications and to better assess the contexts of emission, geographic variation and the functional significance of pulsed signals.
Estimating Potential Incidence of MERS-CoV Associated with Hajj Pilgrims to Saudi Arabia, 2014
Lessler, Justin; Rodriguez-Barraquer, Isabel; Cummings, Derek A.T.; Garske, Tini; Van Kerkhove, Maria; Mills, Harriet; Truelove, Shaun; Hakeem, Rafat; Albarrak, Ali; Ferguson, Neil M.; Aguas, Ricardo; Algarni, Homud; AlHarbi, Khalid; Cauchemez, Simon; Clapham, Hannah; Collins, Caitlin; Cori, Anne; Donnelly, Christl; Fraser, Christophe; Jombart, Thibaut; Moore, Sean M.; Nouvellet, Pierre; Riley, Steven; Salje, Henrik; Turkistani, Abdulhafiz
2014-01-01
Between March and June 2014 the Kingdom of Saudi Arabia (KSA) had a large outbreak of MERS-CoV, renewing fears of a major outbreak during the Hajj this October. Using KSA Ministry of Health data, the MERS-CoV Scenario and Modeling Working Group forecast incidence under three scenarios. In the expected incidence scenario, we estimate 6.2 (95% Prediction Interval [PI]: 1–17) pilgrims will develop MERS-CoV symptoms during the Hajj, and 4.0 (95% PI: 0–12) foreign pilgrims will be infected but return home before developing symptoms. In the most pessimistic scenario, 47.6 (95% PI: 32–66) cases will develop symptoms during the Hajj, and 29.0 (95% PI: 17–43) will be infected but return home asymptomatic. Large numbers of MERS-CoV cases are unlikely to occur during the 2014 Hajj even under pessimistic assumptions, but careful monitoring is still needed to detect possible mass infection events and minimize introductions into other countries. PMID:25685624
Prevalence of paratuberculosis in the dairy goat and dairy sheep industries in Ontario, Canada.
Bauman, Cathy A; Jones-Bitton, Andria; Menzies, Paula; Toft, Nils; Jansen, Jocelyn; Kelton, David
2016-02-01
A cross-sectional study was undertaken (October 2010 to August 2011) to estimate the prevalence of paratuberculosis in the small ruminant dairy industries in Ontario, Canada. Blood and feces were sampled from 580 goats and 397 sheep (lactating and 2 y of age or older) that were randomly selected from 29 randomly selected dairy goat herds and 21 convenience-selected dairy sheep flocks. Fecal samples were analyzed using bacterial culture (BD BACTEC MGIT 960) and polymerase chain reaction (Tetracore); serum samples were tested with the Prionics Parachek enzyme-linked immunosorbent assay (ELISA). Using 3-test latent class Bayesian models, true farm-level prevalence was estimated to be 83.0% [95% probability interval (PI): 62.6% to 98.1%] for dairy goats and 66.8% (95% PI: 41.6% to 91.4%) for dairy sheep. The within-farm true prevalence for dairy goats was 35.2% (95% PI: 23.0% to 49.8%) and for dairy sheep was 48.3% (95% PI: 27.6% to 74.3%). These data indicate that a paratuberculosis control program for small ruminants is needed in Ontario.
NASA Astrophysics Data System (ADS)
Teixidor, D.; Ferrer, I.; Ciurana, J.
2012-04-01
This paper reports the characterization of laser machining (milling) process to manufacture micro-channels in order to understand the incidence of process parameters on the final features. Selection of process operational parameters is highly critical for successful laser micromachining. A set of designed experiments is carried out in a pulsed Nd:YAG laser system using AISI H13 hardened tool steel as work material. Several micro-channels have been manufactured as micro-mold cavities varying parameters such as scanning speed (SS), pulse intensity (PI) and pulse frequency (PF). Results are obtained by evaluating the dimensions and the surface finish of the micro-channel. The dimensions and shape of the micro-channels produced with laser-micro-milling process exhibit variations. In general the use of low scanning speeds increases the quality of the feature in both surface finishing and dimensional.
Baker, John [Walnut Creek, CA; Archer, Daniel E [Knoxville, TN; Luke, Stanley John [Pleasanton, CA; Decman, Daniel J [Livermore, CA; White, Gregory K [Livermore, CA
2009-06-23
A tailpulse signal generating/simulating apparatus, system, and method designed to produce electronic pulses which simulate tailpulses produced by a gamma radiation detector, including the pileup effect caused by the characteristic exponential decay of the detector pulses, and the random Poisson distribution pulse timing for radioactive materials. A digital signal process (DSP) is programmed and configured to produce digital values corresponding to pseudo-randomly selected pulse amplitudes and pseudo-randomly selected Poisson timing intervals of the tailpulses. Pulse amplitude values are exponentially decayed while outputting the digital value to a digital to analog converter (DAC). And pulse amplitudes of new pulses are added to decaying pulses to simulate the pileup effect for enhanced realism in the simulation.
Fast Spectroscopic Imaging and Field Compensation Using Frequency Modulation at Ultra-High-Field
NASA Astrophysics Data System (ADS)
Jang, Albert Woo Ju
The high energy phosphates (HEP) in the myocardium, which are critical to understanding the cardiac function in both normal and pathophysiologic states, can be assessed non-invasively in vivo using phosphorus-31 (31P) spectroscopy. Compared to proton, for the same volume and magnetic field strength, the available signal-to-noise (SNR) ratio of the HEP metabolites is orders of magnitude lower mainly due to its intrinsically low concentration. Hence, cardiac spectroscopy greatly benefits when performed at ultra-high-fields (UHF, ≥ 7 T), both in terms of increased SNR and increased spectroscopic resolution. However, at ultra-high-field strengths, complications arise from the RF transmit wavelength becoming comparable or smaller than the field-of-view (FOV), thus exhibiting wave-like behavior. Furthermore, even with the spectroscopic resolution afforded at UHF, measuring myocardial inorganic phosphate (Pi) is still a challenge and has been a major barrier in extracting the ATP turnover rate. Recently, an indirect way of extracting the ATP hydrolysis rate forgoing direct measurement of Pi was established. In this work, we combine this method with the T1 nom method to monitor the transmural distribution of forward creatine kinase reaction (kf,CK) and ATP hydrolysis rate (kr,ATPase) of the myocardium, effectively reducing data acquisition time by up to an order of magnitude. In addition, a new class of 2D FM pulses and multidimensional adiabatic pulses are presented, which can compensate for B1 inhomogeneity through its spatiotemporal properties. These pulses should be valuable for spectroscopic applications at ultra-high-fields.
NASA Astrophysics Data System (ADS)
Baltar, F.; Lundin, D.; Palovaara, J.; Reinthaler, T.; Herndl, G. J.; Pinhassi, J.
2016-02-01
Alkaline phosphatase (APase) activity is supposed to be regulated by the concentration of its endproduct, decreasing with increasing inorganic phosphate (Pi) concentrations. Since Pi is readily available in the deep ocean, APase activity would be expected to be low. However, high APase activities at high Pi concentrations have been found in the deep Indian and Atlantic Ocean. To understand how APase activities are regulated and what mechanisms are responsible for its regulation we performed microcosm experiments with mesopelagic North Atlantic waters. Treatments consisted of enrichment with either ammonium or organic carbon, and were compared to unamended controls. We assessed changes in prokaryotic abundance, APase, leucine aminopeptidase, heterotrophic production, dark CO2 fixation and community gene expression (metatranscriptomics) between treatments and control. In the organic matter enrichments, APase increased along with all measured rates, whereas only dark CO2 fixation and APase were enhanced in the ammonium enrichment. In the organic matter enrichment, genes for heterotrophic metabolism were strongly upregulated, whereas genes for ammonia oxidation and CO2 fixation were upregulated in the ammonium treatment. In both treatments, the Pho regulon -a global regulatory mechanism involved in bacterial Pi management- was also upregulated, including genes encoding alkaline phosphatases. The activation of the Pho regulon seemed to be related to cross-activation by nonpartner histidine kinases, and/or the activation of genes involved in the regulation of elemental balance during catabolic processes. Increased C or N bioavailability thus appear to elicit a Pi deficiency inside cells and activate the Pho regulon. These results indicate possible ways (e.g. pulses of C or N or changes in elemental ratios) in which APase can be activated irrespectively of the environmental Pi concentration.
NASA Astrophysics Data System (ADS)
Nishimura, Yukitoshi; Kikuchi, Takashi; Ebihara, Yusuke; Yoshikawa, Akimasa; Imajo, Shun; Li, Wen; Utada, Hisashi
2016-08-01
We investigated evolution of ionospheric currents during sudden commencements using a ground magnetometer network in conjunction with an all-sky imager, which has the advantage of locating field-aligned currents much more accurately than ground magnetometers. Preliminary (PI) and main (MI) impulse currents showed two-cell patterns propagating antisunward, particularly during a southward interplanetary magnetic field (IMF). Although this overall pattern is consistent with the Araki (solar wind sources of magnetospheric ultra-low-frequency waves. Geophysical monograph series, vol 81. AGU, Washington, DC, pp 183-200, 1994. doi: 10.1029/GM081p0183) model, we found several interesting features. The PI and MI currents in some events were highly asymmetric with respect to the noon-midnight meridian; the post-noon sector did not show any notable PI signal, but only had an MI starting earlier than the pre-noon MI. Not only equivalent currents but also aurora and equatorial magnetometer data supported the much weaker PI response. We suggest that interplanetary shocks impacting away from the subsolar point caused the asymmetric current pattern. Additionally, even when PI currents form in both pre- and post-noon sectors, they can initiate and disappear at different timings. The PI currents did not immediately disappear but coexisted with the MI currents for the first few minutes of the MI. During a southward IMF, the MI currents formed equatorward of a preexisting DP-2, indicating that the MI currents are a separate structure from a preexisting DP-2. In contrast, the MI currents under a northward IMF were essentially an intensification of a preexisting DP-2. The magnetometer and imager combination has been shown to be a powerful means for tracing evolution of ionospheric currents, and we showed various types of ionospheric responses under different upstream conditions.
Fischer, Ralf-Jörg; Oehmcke, Sonja; Meyer, Uta; Mix, Maren; Schwarz, Katrin; Fiedler, Tomas; Bahl, Hubert
2006-01-01
The pst operon of Clostridium acetobutylicum ATCC 824 comprises five genes, pstS, pstC, pstA, pstB, and phoU, and shows a gene architecture identical to that of Escherichia coli. Deduced proteins are predicted to represent a high-affinity phosphate-specific ABC (ATP-binding cassette) transport system (Pst) and a protein homologous to PhoU, a negative phosphate regulon regulator. We analyzed the expression patterns of the pst operon in Pi-limited chemostat cultures during acid production at pH 5.8 or solvent production at pH 4.5 and in response to Pi pulses. Specific mRNA transcripts were found only when external Pi concentrations had dropped below 0.2 mM. Two specific transcripts were detected, a 4.7-kb polycistronic mRNA spanning the whole operon and a quantitatively dominating 1.2-kb mRNA representing the first gene, pstS. The mRNA levels clearly differed depending on the external pH. The amounts of the full-length mRNA detected were about two times higher at pH 5.8 than at pH 4.5. The level of pstS mRNA increased by a factor of at least 8 at pH 5.8 compared to pH 4.5 results. Primer extension experiments revealed only one putative transcription start point 80 nucleotides upstream of pstS. Thus, additional regulatory sites are proposed in the promoter region, integrating two different extracellular signals, namely, depletion of inorganic phosphate and the pH of the environment. After phosphate pulses were applied to a phosphate-limited chemostat we observed faster phosphate consumption at pH 5.8 than at pH 4.5, although higher optical densities were recorded at pH 4.5. PMID:16855236
Virtual Active Touch Using Randomly Patterned Intracortical Microstimulation
O’Doherty, Joseph E.; Lebedev, Mikhail A.; Li, Zheng; Nicolelis, Miguel A.L.
2012-01-01
Intracortical microstimulation (ICMS) has promise as a means for delivering somatosensory feedback in neuroprosthetic systems. Various tactile sensations could be encoded by temporal, spatial, or spatiotemporal patterns of ICMS. However, the applicability of temporal patterns of ICMS to artificial tactile sensation during active exploration is unknown, as is the minimum discriminable difference between temporally modulated ICMS patterns. We trained rhesus monkeys in an active exploration task in which they discriminated periodic pulse-trains of ICMS (200 Hz bursts at a 10 Hz secondary frequency) from pulse trains with the same average pulse rate, but distorted periodicity (200 Hz bursts at a variable instantaneous secondary frequency). The statistics of the aperiodic pulse trains were drawn from a gamma distribution with mean inter-burst intervals equal to those of the periodic pulse trains. The monkeys distinguished periodic pulse trains from aperiodic pulse trains with coefficients of variation 0.25 or greater. Reconstruction of movement kinematics, extracted from the activity of neuronal populations recorded in the sensorimotor cortex concurrent with the delivery of ICMS feedback, improved when the recording intervals affected by ICMS artifacts were removed from analysis. These results add to the growing evidence that temporally patterned ICMS can be used to simulate a tactile sense for neuroprosthetic devices. PMID:22207642
Proceeding of the 1999 Particle Accelerator Conference. Volume 1
1999-04-02
protons -e.6 within a 35-ns wide pulse . Dynamic shots of high - explosive (HE) during detonation usually had pulses spaced at 1-microsecond intervals... protons per pulse could be obtained by 800 Radiography on a Dynamic Object," 1 1th Biennial Nuclear Explosives MeV H’ injection from the existing 800 MeV...3713 Pondermotive Acceleration of Ions By Relativistically Self-Focused High- Intensity Short Pulse Laser -- A.Maksimchuky, S.Gu, K.Flippo,
NASA Astrophysics Data System (ADS)
Kolmasova, Ivana; Santolik, Ondrej; Farges, Thomas; Rison, William; Lan, Radek; Uhlir, Ludek
2014-05-01
We analyze pulse sequences occurring prior to first return strokes of negative cloud-to-ground lightning flashes. The magnetic-field waveforms are measured close to the thunderstorm using a broad-band analyzer with a sampling interval of 12.5 ns. The electric-field waveforms are measured at the distance of ~ 400 km using an analyzer with a sampling interval of 80 ns. The sequence is usually composed of three parts. It begins with a larger pulse train which is believed to be connected with initial breakdown processes. The train of preliminary breakdown pulses ("B" part) is followed by a relatively low and irregular pulse activity ("I" part), which is sometimes missing. The sequence ends with a pulse train attributed to the stepped leader ("L" part). We recognize two different patterns ("B-I-L" and "B-L" types) in recorded waveforms. For the first time, we analyze the time evolution of the pulse amplitudes in the "B" part of "B-I-L" type sequences. The pulse amplitude is decreasing on average by 34% of the maximum value within a given train. We observe an unusually short duration of sequences. This is probably linked to a low height of the thundercloud. Another possible explanation may be based on an untypical precipitation mix resulting in faster steeped leaders.
Zhang, Xia; Li, Yuqian; Wang, Fang; Zang, Jianguo; Liu, Xiaotian; Zhang, Honglei; Yang, Kaili; Zhang, Gongyuan; Wang, Chongjian
2018-06-07
We examined the independent and cumulative associations of resting heart rate and pulse pressure with metabolic syndrome in Chinese rural population based on epidemiological research. A total of 38,708 participants were derived from the Henan Rural Cohort study. Restricted cubic splines and logistic regression model were used to estimate the odds ratios and 95% confidence intervals of metabolic syndrome risk in relation to resting heart rate and pulse pressure. After adjusting for potential confounders, the odds ratio (95% confidence intervals) of resting heart rate and pulse pressure in the highest quartile with the risk of metabolic syndrome were 1.59 (1.48-1.70) and1.81 (1.67-1.95), respectively. Simultaneously, the cumulative effect analysis indicated that the adjusted the odd ratio of resting heart rate and pulse pressure in the highest quartile was 2.89 (2.40-3.47). Furthermore, there was a significantly additive interaction between resting heart rate and pulse pressure on the risk of metabolic syndrome. Increased resting heart rate and pulse pressure are associated with the higher risk of metabolic syndrome as well as the influences of resting heart rate with pulse pressure might cumulatively increase the risk of metabolic syndrome. However, the potential clinical application remains to be determined. Copyright © 2018. Published by Elsevier B.V.
A Pre-ionization System to Limit Neutral Gas in a Compact Toroid Injector
NASA Astrophysics Data System (ADS)
Allfrey, Ian; Roche, Thomas; Matsumoto, Tadafumi; Garate, Eusebio; Gota, Hiroshi; Asai, Tomohiko; the TAE Team
2016-10-01
Fusion plasmas require long lifetimes and high temperatures, both of which are limited by particle loss, among other factors. Therefore, refueling a long-lived advanced beam-driven field-reversed configuration (FRC) plasma in C-2U is necessary, and injecting a supersonic compact toroid (CT) is an effective means of introducing particles into the FRC core. However, neutral gas that trails the CT into the target chamber cools the FRC. Pre-ionization (PI) system assists the break down between electrodes of the CT injector (CTI), so the amount of introduced gas can be lowered by up to a factor of two, effectively increasing the ionization fraction; thus, reducing the amount of neutral gas in the system. Additionally, the PI decreases the delay in CTI breakdown so a highly reproducible operation is achievable. The PI system consists of a fast, high voltage, pulse discharge circuit coupled to a Teflon insulated semi-rigid coaxial cable inserted into the CTI. System details and experimental data will be presented, in addition to issues such as the introduction of impurities and pre-ionizer lifetime.
NASA Astrophysics Data System (ADS)
Conturo, Thomas Edward
Tissue blood flow, blood content, and water state have been characterized in-situ with new nuclear magnetic resonance imaging techniques. The sensitivities of standard techniques to the physiologic tissue parameters spin density (N_{rm r}) and relaxation times (T_1 and T_2 ) are mathematically defined. A new driven inversion method is developed so that tissue T_1 and T_2 changes produce cooperative intensity changes, yielding high contrast, high signal to noise, and sensitivity to a wider range of tissue parameters. The actual tissue parameters were imaged by automated collection of multiple-echo data having multiple T _1 dependence. Data are simultaneously fit by three-parameters to a closed-form expression, producing lower inter-parameter correlation and parameter noise than in separate T_1 or T_2 methods or pre-averaged methods. Accurate parameters are obtained at different field strengths. Parametric images of pathology demonstrate high sensitivity to tissue heterogeneity, and water content is determined in many tissues. Erythrocytes were paramagnetically labeled to study blood content and relaxation mechanisms. Liver and spleen relaxation were enhanced following 10% exchange of animal blood volumes. Rapid water exchange between intracellular and extracellular compartments was validated. Erythrocytes occupied 12.5% of renal cortex volume, and blood content was uniform in the liver, spleen and kidney. The magnitude and direction of flow velocity was then imaged. To eliminate directional artifacts, a bipolar gradient technique sensitized to flow in different directions was developed. Phase angle was reconstructed instead of intensity since the former has a 2pi -fold higher dynamic range. Images of flow through curves demonstrated secondary flow with a centrifugally-biased laminar profile and stationary velocity peaks along the curvature. Portal vein flow velocities were diminished or reversed in cirrhosis. Image artifacts have been characterized and removed. The foldover in magnified images was eliminated by exciting limited regions with orthogonal pi/2 and pi pulses. Off-midline regions were imaged by tandemly offsetting the phase-encoding and excitation. Artifacts due to non-steady-state conditions were demonstrated. The approach to steady state was defined by operators and vectors, and any repeated series of RF pulses was proven to produce a steady-state. The vector difference between the magnetization and its steady state value is relatively constant during the approach. The repetition time relative to T_1 is the main determinant of approach rate, and off-resonant RF pulses incoherent with the magnetization produce a more rapid approach than on-resonant pulses.
Attosecond transient absorption of a bound wave packet coupled to a smooth continuum
Dahlström, Jan Marcus; Pabst, Stefan; Lindroth, Eva
2017-10-16
Here, we investigate the possibility of using transient absorption of a coherent bound electron wave packet in hydrogen as an attosecond pulse characterization technique. In a recent work, we have shown that photoionization of such a coherent bound electron wave packet opens up for pulse characterization with unprecedented temporal accuracy—independent of the atomic structure—with maximal photoemission at all kinetic energies given a wave packet with zero relative phase. Here, we perform numerical propagation of the time-dependent Schrödinger equation and analytical calculations based on perturbation theory to show that the energy-resolved maximal absorption of photons from the attosecond pulse does not uniquely occur at a zero relative phase of the initial wave packet. Instead, maximal absorption occurs at different relative wave packet phases, distributed as a non-monotonous function with a smoothmore » $$-\\pi /2$$ shift across the central photon energy (given a Fourier-limited Gaussian pulse). Similar results are also found in helium. Our finding is surprising, because it implies that the energy-resolved photoelectrons are not mapped one-to-one with the energy-resolved absorbed photons of the attosecond pulse.« less
Attosecond transient absorption of a bound wave packet coupled to a smooth continuum
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dahlström, Jan Marcus; Pabst, Stefan; Lindroth, Eva
Here, we investigate the possibility of using transient absorption of a coherent bound electron wave packet in hydrogen as an attosecond pulse characterization technique. In a recent work, we have shown that photoionization of such a coherent bound electron wave packet opens up for pulse characterization with unprecedented temporal accuracy—independent of the atomic structure—with maximal photoemission at all kinetic energies given a wave packet with zero relative phase. Here, we perform numerical propagation of the time-dependent Schrödinger equation and analytical calculations based on perturbation theory to show that the energy-resolved maximal absorption of photons from the attosecond pulse does not uniquely occur at a zero relative phase of the initial wave packet. Instead, maximal absorption occurs at different relative wave packet phases, distributed as a non-monotonous function with a smoothmore » $$-\\pi /2$$ shift across the central photon energy (given a Fourier-limited Gaussian pulse). Similar results are also found in helium. Our finding is surprising, because it implies that the energy-resolved photoelectrons are not mapped one-to-one with the energy-resolved absorbed photons of the attosecond pulse.« less
Miller, Douglas L; Dou, Chunyan; Owens, Gabe E; Kripfgans, Oliver D
2014-06-01
Intermittent high intensity ultrasound scanning with contrast microbubbles can induce scattered cavitation microlesions in the myocardium, which may be of value for tissue reduction therapy. Anesthetized rats were treated in a heated water bath with 1.5 MHz focused ultrasound pulses, guided by an 8 MHz imaging transducer. The relative efficacy with 2 or 4 MPa pulses, 1:4 or 1:8 trigger intervals and 5 or 10 cycle pulses was explored in six groups. Electrocardiogram premature complexes (PCs) induced by the triggered pulse bursts were counted, and Evans blue stained cardiomyocyte scores (SCSs) were obtained. The increase from 2 to 4 MPa produced significant increases in PCs and SCSs and eliminated an anticipated decline in the rate of PC induction with time, which might hinder therapeutic efficacy. Increased intervals and pulse durations did not yield significant increases in the effects. The results suggest that cavitation microlesion production can be refined and potentially lead to a clinically robust therapeutic method. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Modeling and Simulation of a 5.8kV SiC PiN Diode for Inductive Pulsed Plasma Thruster Applications
NASA Technical Reports Server (NTRS)
Toftul, Alexandra; Hudgins, Jerry L.; Polzin, Kurt A.; Martin, Adam K.
2014-01-01
Current ringing in an Inductive Pulsed Plasma Thruster (IPPT) can lead to reduced energy efficiency, excess heating, and wear on circuit components such as capacitors and solid state devices. Clamping off the current using a fast turn-off power diode is an effective way to reduce current ringing and increase energy efficiency. A diode with a shorter reverse recovery time will allow the least amount of current to ring back through the circuit, as well as minimize switching losses. The reverse recovery response of a new 5.8 kilovolt SiC PiN diode from Cree, Inc. in the IPPT plasma drive circuit is investigated using a physicsbased Simulink model, and compared with that of a 5SDF 02D6004 5.5 kilovolt fast-switching Si diode from ABB. Parameter extraction was carried out for each diode using both datasheet specifications and experimental waveforms, in order to most accurately adapt the model to the specific device. Further experimental data will be discussed using a flat-plate IPPT developed at NASA Marshall Space Flight Center and used to verify the simulation results. A final quantitative measure of circuit efficiency will be described for both the Si and SiC diode configuration.
NASA Technical Reports Server (NTRS)
Khakoo, M. A.; Johnson, P. V.; Ozkay, I.; Yan, P.; Trajmar, S.; Kanik, I.
2005-01-01
Measurements of differential cross sections for the electron-impact excitation of molecular nitrogen from the ground X(sup 1)(Sigma)(sub g)(sup +)(v''=0)level to the A(sup 3)(Sigma)(sub u)(sup +)(v'), B(sup 3)Pi(sub g)(v'), W(sup 3)(Delta)(sub u)(v'),B'(sup 3)(Sigma)(sub u)(sup -)(v'), a(sup 1)(Pi)(sub g)(v'), w(sup 1)(Delta)(sub u)(v'), and C(sup 3)(Pi)(sub u)(v') levels are presented. The data are obtained at the incident energies of 10, 12.5, 15, 17.5, 20, 30, 50, and 100 eV over the angular range of 5(deg)-130(deg) in 5(deg) intervals. The individual electronic state excitation differential cross sections are obtained by unfolding electron energy-loss spectra of molecular nitrogen using available semiempirical Frank-Condon factors. The data are compared to previous measurements and to available theory. We also make several important suggestions regarding future work that, like the present, relies on the unfolding of electron energy-loss spectra for obtaining differential cross sections.
Shang, Chi-Yung; Sheng, Chia; Yang, Li-Kuang; Chou, Tai-Li; Gau, Susan Shur-Fen
2018-06-01
Although previous functional neuroimaging studies have found abnormal brain activations in individuals with attention deficit hyperactivity disorder (ADHD), little was known about distinct brain dysfunctions across different ADHD subtypes. The objective of the present study was to investigate the abnormal brain activations associated with two ADHD subtypes, predominantly inattentive (ADHD-PI) and combined (ADHD-C) subtypes. Twenty-five adults with ADHD-PI, 25 with ADHD-C, and 30 healthy controls (HC) participated in this study. The brain function of the participants were assessed by using the counting Stroop task inside the scanner and the Conners' Continuous Performance Test (CCPT) outside the scanner. The HC group showed greater activations in the caudate nucleus and inferior frontal gyrus (IFG) than the ADHD-PI and ADHD-C groups. The ADHD-PI group showed greater activations in the superior parietal lobule (SPL) than the ADHD-C group. In all participants with ADHD, we found negative correlations of activation in the left caudate and the left IFG with the standard deviation of the reaction time of the CCPT, and negative correlations of activation in the left SPL with the reaction time changes across different inter-stimulus intervals. Our results demonstrated altered brain activity in the frontostriatal networks of adults with ADHD-PI and the fronto-striato-parietal networks of adults with ADHD-C. Abnormalities in the parietal areas may represent the main difference between the ADHD-PI and ADHD-C subtypes.
Veyrinas, K; Gruson, V; Weber, S J; Barreau, L; Ruchon, T; Hergott, J-F; Houver, J-C; Lucchese, R R; Salières, P; Dowek, D
2016-12-16
Due to the intimate anisotropic interaction between an XUV light field and a molecule resulting in photoionization (PI), molecular frame photoelectron angular distributions (MFPADs) are most sensitive probes of both electronic/nuclear dynamics and the polarization state of the ionizing light field. Consequently, they encode the complex dipole matrix elements describing the dynamics of the PI transition, as well as the three normalized Stokes parameters s 1 , s 2 , s 3 characterizing the complete polarization state of the light, operating as molecular polarimetry. The remarkable development of advanced light sources delivering attosecond XUV pulses opens the perspective to visualize the primary steps of photochemical dynamics in time-resolved studies, at the natural attosecond to few femtosecond time-scales of electron dynamics and fast nuclear motion. It is thus timely to investigate the feasibility of measurement of MFPADs when PI is induced e.g., by an attosecond pulse train (APT) corresponding to a comb of discrete high-order harmonics. In the work presented here, we report MFPAD studies based on coincident electron-ion 3D momentum imaging in the context of ultrafast molecular dynamics investigated at the PLFA facility (CEA-SLIC), with two perspectives: (i) using APTs generated in atoms/molecules as a source for MFPAD-resolved PI studies, and (ii) taking advantage of molecular polarimetry to perform a complete polarization analysis of the harmonic emission of molecules, a major challenge of high harmonic spectroscopy. Recent results illustrating both aspects are reported for APTs generated in unaligned SF 6 molecules by an elliptically polarized infrared driving field. The observed fingerprints of the elliptically polarized harmonics include the first direct determination of the complete s 1 , s 2 , s 3 Stokes vector, equivalent to (ψ, ε, P), the orientation and the signed ellipticity of the polarization ellipse, and the degree of polarization P. They are compared to so far incomplete results of XUV optical polarimetry. We finally discuss the comparison between the outcomes of photoionization and high harmonic spectroscopy for the description of molecular photodynamics.
Characteristics of biosonar signals from the northern bottlenose whale, Hyperoodon ampullatus.
Wahlberg, Magnus; Beedholm, Kristian; Heerfordt, Anders; Møhl, Bertel
2011-11-01
The biosonar pulses from free-ranging northern bottlenose whales (Hyperoodon ampullatus) were recorded with a linear hydrophone array. Signals fulfilling criteria for being recorded close to the acoustic axis of the animal (a total of 10 clicks) had a frequency upsweep from 20 to 55 kHz and durations of 207 to 377 μs (measured as the time interval containing 95% of the signal energy). The source level of these signals, denoted pulses, was 175-202 dB re 1 μPa rms at 1 m. The pulses had a directionality index of at least 18 dB. Interpulse intervals ranged from 73 to 949 ms (N = 856). Signals of higher repetition rates had interclick intervals of 5.8-13.1 ms (two sequences, made up of 59 and 410 clicks, respectively). These signals, denoted clicks, had a shorter duration (43-200 μs) and did not have the frequency upsweep characterizing the pulses of low repetition rates. The data show that the northern bottlenose whale emits signals similar to three other species of beaked whale. These signals are distinct from the three other types of biosonar signals of toothed whales. It remains unclear why the signals show this grouping, and what consequences it has on echolocation performance.
Application of millisecond pulsed laser for thermal fatigue property evaluation
NASA Astrophysics Data System (ADS)
Pan, Sining; Yu, Gang; Li, Shaoxia; He, Xiuli; Xia, Chunyang; Ning, Weijian; Zheng, Caiyun
2018-02-01
An approach based on millisecond pulsed laser is proposed for thermal fatigue property evaluation in this paper. Cyclic thermal stresses and strains within millisecond interval are induced by complex and transient temperature gradients with pulsed laser heating. The influence of laser parameters on surface temperature is studied. The combination of low pulse repetition rate and high pulse energy produces small temperature oscillation, while high pulse repetition rate and low pulse energy introduces large temperature shock. The possibility of application is confirmed by two thermal fatigue tests of compacted graphite iron with different laser controlled modes. The developed approach is able to fulfill the preset temperature cycles and simulate thermal fatigue failure of engine components.
NASA Technical Reports Server (NTRS)
Leskovar, B.; Turko, B.
1977-01-01
The development of a high precision time interval digitizer is described. The time digitizer is a 10 psec resolution stop watch covering a range of up to 340 msec. The measured time interval is determined as a separation between leading edges of a pair of pulses applied externally to the start input and the stop input of the digitizer. Employing an interpolation techniques and a 50 MHz high precision master oscillator, the equivalent of a 100 GHz clock frequency standard is achieved. Absolute accuracy and stability of the digitizer are determined by the external 50 MHz master oscillator, which serves as a standard time marker. The start and stop pulses are fast 1 nsec rise time signals, according to the Nuclear Instrument means of tunnel diode discriminators. Firing level of the discriminator define start and stop points between which the time interval is digitized.
Periodical energy oscillation and pulse splitting in sinusoidal volume holographic grating.
Yan, Xiaona; Gao, Lirun; Dai, Ye; Yang, Xihua; Chen, Yuanyuan; Ma, Guohong
2014-07-28
This paper presents dynamical diffraction properties of a femtosecond pulse in a sinusoidal volume holographic grating (VHG). By the modified coupled-wave equations of Kogelnik, we show that the diffraction of a femtosecond pulse on the VHG gives rise to periodical energy oscillation and pulse splitting. In the initial stage of diffraction, one diffracted pulse and one transmitted pulse emerge, and energy of the transmitted pulse periodically transfers to the diffracted pulse and vice versa. In the latter stage, both the diffracted and transmitted pulses split into two spatially separated pulses. One pair of transmitted and diffracted pulses propagates in the same direction and forms the output diffracted dual pulses of the VHG, and the other pair of pulses forms the output transmitted dual pulses. The pulse interval between each pair of dual pulses is in linearly proportional to the refractive index modulation and grating thickness. By the interference effect and group velocity difference we give explanations on the periodical energy oscillation and pulse splitting respectively.
Saleem, Mahmood; Khan, Rafi Ullah; Tahir, M. Suleman; Krammer, Gernot
2011-01-01
Pulse-jet bag filters are frequently employed for particle removal from off gases. Separated solids form a layer on the permeable filter media called filter cake. The cake is responsible for increasing pressure drop. Therefore, the cake has to be detached at a predefined upper pressure drop limit or at predefined time intervals. Thus the process is intrinsically semi-continuous. The cake formation and cake detachment are interdependent and may influence the performance of the filter. Therefore, understanding formation and detachment of filter cake is important. In this regard, the filter media is the key component in the system. Needle felts are the most commonly used media in bag filters. Cake formation studies with heat treated and membrane coated needle felts in pilot scale pulse jet bag filter were carried out. The data is processed according to the procedures that were published already [Powder Technology, Volume 173, Issue 2, 19 April 2007, Pages 93–106]. Pressure drop evolution, cake height distribution evolution, cake patches area distribution and their characterization using fractal analysis on different needle felts are presented here. It is observed that concavity of pressure drop curve for membrane coated needle felt is principally caused by presence of inhomogeneous cake area load whereas it is inherent for heat treated media. Presence of residual cake enhances the concavity of pressure drop at the start of filtration cycle. Patchy cleaning is observed only when jet pulse pressure is too low and unable to provide the necessary force to detach the cake. The border line is very sharp. Based on experiments with limestone dust and three types of needle felts, for the jet pulse pressure above 4 bar and filtration velocity below 50 mm/s, cake is detached completely except a thin residual layer (100–200 μm). Uniformity and smoothness of residual cake depends on the surface characteristics of the filter media. Cake height distribution of residual cake and newly formed cake during filtration prevails. The patch size analysis and fractal analysis reveal that residual cake grow in size (latterly) following regeneration initially on the base with edges smearing out, however, the cake heights are not leveled off. Fractal dimension of cake patches boundary falls in the range of 1–1.4 and depends on vertical position as well as time of filtration. Cake height measurements with Polyimide (PI) needle felts were hampered on account of its photosensitive nature. PMID:24415801
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loiko, Yurii; Institute of Molecular and Atomic Physics, National Academy of Sciences of Belarus, Nezaleznasty Ave. 70, 220072 Minsk; Serrat, Carles
2006-06-15
Propagation of single- and two-color hyperbolic secant femtosecond laser pulses in a three-level {lambda}-type quantum system is investigated by solving the Maxwell and density matrix equations with the finite-difference time-domain and Runge-Kutta methods. As a first study of our modeling, we simulate pulse self-induced transparency (SIT) in two-level systems and see how this phenomenon can be controlled by manipulating the initial relative phase between the SIT pulse and a second control pulse, provided the ratio between both pulse frequencies obeys the relation {omega}{sub 1}/{omega}{sub 2}=3. We then examine frequency down-conversion processes that are observed with single- and two-color pulses themore » envelope area of which is equal to or a multiple of 2{pi}, for pulse frequencies close to resonance with the transitions of a three-level {lambda} medium. Also, phase-sensitive phenomena are discussed in the case of two-color {omega}-3{omega} pulses propagating resonantly in the three-level system. In particular, possibilities for such coherent control are found for frequency down-conversion processes when the ratio of the frequencies of optical transitions is {omega}{sub 13}/{omega}{sub 12}=3. The conditions for quantum control of four-wave mixing processes are also examined when the pulse frequencies of two-color {omega}-3{omega} pulses are far from any resonance of the three-level system. We demonstrate the possibility to cancel the phase sensitivity of the four-wave coupling in a {lambda}-type system by competition effects between optical transitions.« less
Low Probability of Intercept Laser Range Finder
2017-07-19
time of arrival, and it may also include wavelength, pulse width, and pulse repetition frequency (PRF). Second photodetector 38 in conjunction with... conjunction with lens 32 and telescope 36 that can correct for turbulence along the free space path. [0024] In all embodiments, the time interval
Chaotic carrier pulse position modulation communication system and method
Abarbanel, Henry D. I.; Larson, Lawrence E.; Rulkov, Nikolai F.; Sushchik, Mikhail M.; Tsimring, Lev S.; Volkovskii, Alexander R.
2001-01-01
A chaotic carrier pulse position modulation communication system and method is disclosed. The system includes a transmitter and receiver having matched chaotic pulse regenerators. The chaotic pulse regenerator in the receiver produces a synchronized replica of a chaotic pulse train generated by the regenerator in the transmitter. The pulse train from the transmitter can therefore act as a carrier signal. Data is encoded by the transmitter through selectively altering the interpulse timing between pulses in the chaotic pulse train. The altered pulse train is transmitted as a pulse signal. The receiver can detect whether a particular interpulse interval in the pulse signal has been altered by reference to the synchronized replica it generates, and can therefore detect the data transmitted by the receiver. Preferably, the receiver predicts the earliest moment in time it can expect a next pulse after observation of at least two consecutive pulses. It then decodes the pulse signal beginning at a short time before expected arrival of a pulse.
Beam control in the ETA-II linear induction accelerator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Yu-Jiuan
1992-08-21
Corkscrew beam motion is caused by chromatic aberration and misalignment of a focusing system. We have taken some measures to control the corkscrew motion on the ETA-11 induction accelerator. To minimize chromatic aberration, we have developed an energy compensation scheme which reduces energy sweep and differential phase advance within a beam pulse. To minimize the misalignment errors, we have developed a time-independent steering algorithm which minimizes the observed corkscrew amplitude averaged over the beam pulse. The steering algorithm can be used even if the monitor spacing is much greater than the system`s cyclotron wavelength and the corkscrew motion caused bymore » a given misaligned magnet is fully developed, i.e., the relative phase advance is greater than 27{pi}.« less
Beam control in the ETA-II linear induction accelerator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Yu-Jiuan.
1992-08-21
Corkscrew beam motion is caused by chromatic aberration and misalignment of a focusing system. We have taken some measures to control the corkscrew motion on the ETA-11 induction accelerator. To minimize chromatic aberration, we have developed an energy compensation scheme which reduces energy sweep and differential phase advance within a beam pulse. To minimize the misalignment errors, we have developed a time-independent steering algorithm which minimizes the observed corkscrew amplitude averaged over the beam pulse. The steering algorithm can be used even if the monitor spacing is much greater than the system's cyclotron wavelength and the corkscrew motion caused bymore » a given misaligned magnet is fully developed, i.e., the relative phase advance is greater than 27[pi].« less
Event-based proactive interference in rhesus monkeys.
Devkar, Deepna T; Wright, Anthony A
2016-10-01
Three rhesus monkeys (Macaca mulatta) were tested in a same/different memory task for proactive interference (PI) from prior trials. PI occurs when a previous sample stimulus appears as a test stimulus on a later trial, does not match the current sample stimulus, and the wrong response "same" is made. Trial-unique pictures (scenes, objects, animals, etc.) were used on most trials, except on trials where the test stimulus matched potentially interfering sample stimulus from a prior trial (1, 2, 4, 8, or 16 trials prior). Greater interference occurred when fewer trials separated interference and test. PI functions showed a continuum of interference. Delays between sample and test stimuli and intertrial intervals were manipulated to test how PI might vary as a function of elapsed time. Contrary to a similar study with pigeons, these time manipulations had no discernable effect on the monkey's PI, as shown by compete overlap of PI functions with no statistical differences or interactions. These results suggested that interference was strictly based upon the number of intervening events (trials with other pictures) without regard to elapsed time. The monkeys' apparent event-based interference was further supported by retesting with a novel set of 1,024 pictures. PI from novel pictures 1 or 2 trials prior was greater than from familiar pictures, a familiar set of 1,024 pictures. Moreover, when potentially interfering novel stimuli were 16 trials prior, performance accuracy was actually greater than accuracy on baseline trials (no interference), suggesting that remembering stimuli from 16 trials prior was a cue that this stimulus was not the sample stimulus on the current trial-a somewhat surprising conclusion particularly given monkeys.
González-Rubio, Raquel; Escortell-Mayor, Esperanza; Del Cura González, Isabel
2017-10-06
To assess the frequency of exposure and attitudes to the pharmaceutical industry (PI) of residents in the Region of Madrid (RM), Spain, and to analyse the association with specialty, professional environment and training. Cross-sectional electronic survey in May and June 2015 of all medical residents in RM. We collected sociodemographic variables and those of interaction with the PI in four blocks: frequency of interactions, attitudes and perceptions, environment and regulatory framework, and skills; with the first two blocks we created a Synthetic PI Interaction Index (SPIII). Bivariate and multivariate analysis of logistic regression. 350 resident's responses (28% family and community medicine [FCM], 57% hospital, 15% others). Ninety-eight percent reported interacting with the PI. Twenty percent believed their prescribing was influenced by the PI and 48% believed it was influenced by other doctors. Sixty-five precent considered more training necessary. Ninety-six percent had received no information from their college of physicians, 80% did not know the regulations in their medical society and 50% were unaware of those of their institution. Hospital specialty residents showed more likelihood of SPIII ≥ percentile 75 than those of FCM (odds ratio [OR]: 3.96; 95% confidence interval [95%CI]: 1.88-8.35). Training in informal settings was associated with SPIII ≤ percentile 25 (OR: 2.83; 95%CI: 1.32-6.07). The medical residents in RM had a high level of interaction with the PI and believed its influence low. Hospital specialty residents showed more interaction with the PI. Regulations were not well known by residents and they consideredmore training necessary. Copyright © 2017 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.
Ishizuka, Mitsuru; Shibuya, Norisuke; Nagata, Hitoshi; Takagi, Kazutoshi; Iwasaki, Yoshimi; Hachiya, Hiroyuki; Aoki, Taku; Kubota, Keiichi
2017-11-01
Although it has been widely demonstrated that administration of Daikenchuto (DKT), a traditional Japanese herbal medicine, improves gastrointestinal (GI) motility in patients undergoing abdominal surgery, few studies have investigated the efficacy of perioperative DKT administration for relief of postoperative ileus (PI) in patients undergoing surgery for GI cancer. Therefore, the aim of this study was to investigate whether perioperative administration of DKT relieves PI in patients with GI cancer. We performed a comprehensive electronic search of the literature (Cochrane Library, PubMed, the Web of Science and ICHUSHI) up to December 2016 to identify studies that had shown the efficacy of perioperative DKT administration for relief of PI in patients with GI cancer. To integrate the individual effect of DKT, a meta-analysis was performed using random-effects models to calculate the risk ratio (RR) and 95% confidence interval (CI), and heterogeneity was analyzed using I 2 statistics. Seven studies involving a total of 1,134 patients who had undergone GI cancer surgery were included in this meta-analysis. Among 588 patients who received DKT perioperatively, 67 (11.4%) had PI, whereas among 546 patients who did not receive DKT perioperatively, 87 (15.9%) had PI. Perioperative administration of DKT significantly reduced the occurrence of PI (RR=0.58, 95% CI=0.35-0.97, p=0.04, I 2 =48%) in comparison to patients who did not receive DKT or received placebo. The result of this meta-analysis suggests that perioperative administration of DKT relieves PI in patients undergoing surgery for GI cancer. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Sörstedt, Erik; Carlander, Christina; Flamholc, Leo; Hejdeman, Bo; Svedhem, Veronica; Sönnerborg, Anders; Gisslén, Magnus; Yilmaz, Aylin
2018-05-01
Until the introduction of dolutegravir (DTG), people living with HIV (PLWH) who have developed nucleoside reverse transcriptase inhibitor (NRTI) mutations have had few other treatment options outside of regimens based on ritonavir-boosted protease inhibitors (PI/r). Here we report treatment results among PLWH in Sweden with pre-existing NRTI mutations on antiretroviral treatment (ART) with DTG and one to two NRTIs. All PLWH on ART with DTG and one to two NRTIs with pre-existing NRTI mutations were retrospectively identified from the National InfCare HIV database. As controls, PLWH on PI/r and one to two NRTIs, matched according to Genotypic Susceptibility Score and observation time, were included. Data were collected as long as the study population was on treatment with DTG; controls were monitored for the same interval. Outcome was classified as either treatment success or failure. In total, 244 participants (122 individuals treated with DTG and 122 individuals treated with PI/r) were included. Median observation time was 78 weeks (interquartile range 50-98 weeks) for participants on DTG and 75 weeks (50-101 weeks) for individuals on PI/r. Viral failure was detected in four individuals treated with DTG and three individuals treated with PI/r, resulting in similar success rates of 96.7% and 97.5%, respectively. No new mutations were found among participants with treatment failure. DTG in combination with one to two NRTIs was as efficient as PI/r in individuals with pre-existing NRTI mutations in this setting. It may be considered an alternative to PI/r-based ART even in the presence of NRTI resistance. Copyright © 2018 Elsevier B.V. and International Society of Chemotherapy. All rights reserved.
A Gaussian Model-Based Probabilistic Approach for Pulse Transit Time Estimation.
Jang, Dae-Geun; Park, Seung-Hun; Hahn, Minsoo
2016-01-01
In this paper, we propose a new probabilistic approach to pulse transit time (PTT) estimation using a Gaussian distribution model. It is motivated basically by the hypothesis that PTTs normalized by RR intervals follow the Gaussian distribution. To verify the hypothesis, we demonstrate the effects of arterial compliance on the normalized PTTs using the Moens-Korteweg equation. Furthermore, we observe a Gaussian distribution of the normalized PTTs on real data. In order to estimate the PTT using the hypothesis, we first assumed that R-waves in the electrocardiogram (ECG) can be correctly identified. The R-waves limit searching ranges to detect pulse peaks in the photoplethysmogram (PPG) and to synchronize the results with cardiac beats--i.e., the peaks of the PPG are extracted within the corresponding RR interval of the ECG as pulse peak candidates. Their probabilities of being the actual pulse peak are then calculated using a Gaussian probability function. The parameters of the Gaussian function are automatically updated when a new pulse peak is identified. This update makes the probability function adaptive to variations of cardiac cycles. Finally, the pulse peak is identified as the candidate with the highest probability. The proposed approach is tested on a database where ECG and PPG waveforms are collected simultaneously during the submaximal bicycle ergometer exercise test. The results are promising, suggesting that the method provides a simple but more accurate PTT estimation in real applications.
Tellechea, J S; Fine, M L; Norbis, W
2017-04-01
Disturbance and advertisement calls of the Argentine croaker Umbrina canosai were recorded from coastal Uruguayan waters. Dissections indicate typical sciaenid extrinsic swimbladder muscles present exclusively in males. Disturbance calls were produced when captive U. canosai were startled, chased with a net or grabbed by the tail. Calls were unusual for sciaenids because each pulse consisted of multiple cycles. The number of cycles per pulse and dominant frequency did not change with U. canosai size, but pulse duration and interpulse interval increased. Advertisement calls were recorded from unseen choruses in the field and confirmed with captive individuals in a large tank. Advertisement calls were recorded throughout the known range of the species in Uruguay indicating a continuous belt of spawning populations. Tank recordings of the same individuals permitted explicit comparisons between the two calls. Advertisement call pulses averaged 2·4 more cycles (11·0-8·6) although pulses of both calls were basically similar as were durations and dominant frequencies. Pulse number, however, differed markedly, averaging 13·6 and 3·4 pulses for disturbance and advertisement calls respectively. Furthermore, disturbance calls were produced as a rapid series with an interpulse interval of 26-31 ms whereas advertisement call patterns were less stereotyped and ranged from <100 to 450 ms. Multicycle pulses distinguished U. canosai from other sympatric sciaenids. © 2017 The Fisheries Society of the British Isles.
NASA Technical Reports Server (NTRS)
Lawson, R. Paul
2000-01-01
SPEC incorporated designed, built and operated a new instrument, called a pi-Nephelometer, on the NASA DC-8 for the SUCCESS field project. The pi-Nephelometer casts an image of a particle on a 400,000 pixel solid-state camera by freezing the motion of the particle using a 25 ns pulsed, high-power (60 W) laser diode. Unique optical imaging and particle detection systems precisely detect particles and define the depth-of-field so that at least one particle in the image is almost always in focus. A powerful image processing engine processes frames from the solid-state camera, identifies and records regions of interest (i.e. particle images) in real time. Images of ice crystals are displayed and recorded with 5 micron pixel resolution. In addition, a scattered light system simultaneously measures the scattering phase function of the imaged particle. The system consists of twenty-eight 1-mm optical fibers connected to microlenses bonded on the surface of avalanche photo diodes (APDs). Data collected with the pi-Nephelometer during the SUCCESS field project was reported in a special issue of Geophysical Research Letters. The pi-Nephelometer provided the basis for development of a commercial imaging probe, called the cloud particle imager (CPI), which has been installed on several research aircraft and used in More than a dozen field programs.
A new time calibration method for switched-capacitor-array-based waveform samplers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, H.; Chen, C. -T.; Eclov, N.
2014-08-24
Here we have developed a new time calibration method for the DRS4 waveform sampler that enables us to precisely measure the non-uniform sampling interval inherent in the switched-capacitor cells of the DRS4. The method uses the proportionality between the differential amplitude and sampling interval of adjacent switched-capacitor cells responding to a sawtooth-shape pulse. In the experiment, a sawtooth-shape pulse with a 40 ns period generated by a Tektronix AWG7102 is fed to a DRS4 evaluation board for calibrating the sampling intervals of all 1024 cells individually. The electronic time resolution of the DRS4 evaluation board with the new time calibrationmore » is measured to be ~2.4 ps RMS by using two simultaneous Gaussian pulses with 2.35 ns full-width at half-maximum and applying a Gaussian fit. The time resolution dependencies on the time difference with the new time calibration are measured and compared to results obtained by another method. Ultimately, the new method could be applicable for other switched-capacitor-array technology-based waveform samplers for precise time calibration.« less
A new time calibration method for switched-capacitor-array-based waveform samplers
NASA Astrophysics Data System (ADS)
Kim, H.; Chen, C.-T.; Eclov, N.; Ronzhin, A.; Murat, P.; Ramberg, E.; Los, S.; Moses, W.; Choong, W.-S.; Kao, C.-M.
2014-12-01
We have developed a new time calibration method for the DRS4 waveform sampler that enables us to precisely measure the non-uniform sampling interval inherent in the switched-capacitor cells of the DRS4. The method uses the proportionality between the differential amplitude and sampling interval of adjacent switched-capacitor cells responding to a sawtooth-shape pulse. In the experiment, a sawtooth-shape pulse with a 40 ns period generated by a Tektronix AWG7102 is fed to a DRS4 evaluation board for calibrating the sampling intervals of all 1024 cells individually. The electronic time resolution of the DRS4 evaluation board with the new time calibration is measured to be 2.4 ps RMS by using two simultaneous Gaussian pulses with 2.35 ns full-width at half-maximum and applying a Gaussian fit. The time resolution dependencies on the time difference with the new time calibration are measured and compared to results obtained by another method. The new method could be applicable for other switched-capacitor-array technology-based waveform samplers for precise time calibration.
A New Time Calibration Method for Switched-capacitor-array-based Waveform Samplers.
Kim, H; Chen, C-T; Eclov, N; Ronzhin, A; Murat, P; Ramberg, E; Los, S; Moses, W; Choong, W-S; Kao, C-M
2014-12-11
We have developed a new time calibration method for the DRS4 waveform sampler that enables us to precisely measure the non-uniform sampling interval inherent in the switched-capacitor cells of the DRS4. The method uses the proportionality between the differential amplitude and sampling interval of adjacent switched-capacitor cells responding to a sawtooth-shape pulse. In the experiment, a sawtooth-shape pulse with a 40 ns period generated by a Tektronix AWG7102 is fed to a DRS4 evaluation board for calibrating the sampling intervals of all 1024 cells individually. The electronic time resolution of the DRS4 evaluation board with the new time calibration is measured to be ~2.4 ps RMS by using two simultaneous Gaussian pulses with 2.35 ns full-width at half-maximum and applying a Gaussian fit. The time resolution dependencies on the time difference with the new time calibration are measured and compared to results obtained by another method. The new method could be applicable for other switched-capacitor-array technology-based waveform samplers for precise time calibration.
A New Time Calibration Method for Switched-capacitor-array-based Waveform Samplers
Kim, H.; Chen, C.-T.; Eclov, N.; Ronzhin, A.; Murat, P.; Ramberg, E.; Los, S.; Moses, W.; Choong, W.-S.; Kao, C.-M.
2014-01-01
We have developed a new time calibration method for the DRS4 waveform sampler that enables us to precisely measure the non-uniform sampling interval inherent in the switched-capacitor cells of the DRS4. The method uses the proportionality between the differential amplitude and sampling interval of adjacent switched-capacitor cells responding to a sawtooth-shape pulse. In the experiment, a sawtooth-shape pulse with a 40 ns period generated by a Tektronix AWG7102 is fed to a DRS4 evaluation board for calibrating the sampling intervals of all 1024 cells individually. The electronic time resolution of the DRS4 evaluation board with the new time calibration is measured to be ~2.4 ps RMS by using two simultaneous Gaussian pulses with 2.35 ns full-width at half-maximum and applying a Gaussian fit. The time resolution dependencies on the time difference with the new time calibration are measured and compared to results obtained by another method. The new method could be applicable for other switched-capacitor-array technology-based waveform samplers for precise time calibration. PMID:25506113
Tsao, Connie W; Pencina, Karol M; Massaro, Joseph M; Benjamin, Emelia J; Levy, Daniel; Vasan, Ramachandran S; Hoffmann, Udo; O'Donnell, Christopher J; Mitchell, Gary F
2014-11-01
Arterial hemodynamics and vascular calcification are associated with increased risk for cardiovascular disease, but their inter-relations remain unclear. We sought to examine the associations of arterial stiffness, pressure pulsatility, and wave reflection with arterial calcification in individuals free of prevalent cardiovascular disease. Framingham Heart Study Third Generation and Offspring Cohort participants free of cardiovascular disease underwent applanation tonometry to measure arterial stiffness, pressure pulsatility, and wave reflection, including carotid-femoral pulse wave velocity, central pulse pressure, forward wave amplitude, and augmentation index. Participants in each cohort (n=1905, 45±6 years and n=1015, 65±9 years, respectively) underwent multidetector computed tomography to assess the presence and quantity of thoracic aortic calcification, abdominal aortic calcification, and coronary artery calcification. In multivariable-adjusted models, both higher carotid-femoral pulse wave velocity and central pulse pressure were associated with greater thoracic aortic calcification and abdominal aortic calcification, whereas higher augmentation index was associated with abdominal aortic calcification. Among the tonometry measures, carotid-femoral pulse wave velocity was the strongest correlate of all calcification measures in multivariable-adjusted models (odds ratio per SD for thoracic aortic calcification, 2.69 [95% confidence interval, 2.17-3.35]; abdominal aortic calcification, 1.47 [95% confidence interval, 1.26-1.73]; and coronary artery calcification, 1.48 [95% confidence interval, 1.28-1.72]; all P<0.001, respectively). We observed stronger relations of carotid-femoral pulse wave velocity, central pulse pressure, and forward wave amplitude with nearly all continuous calcification measures in the younger Third Generation Cohort as compared with the Offspring Cohort. In community-dwelling individuals without prevalent cardiovascular disease, abnormal central arterial hemodynamics were positively associated with vascular calcification and were observed at younger ages than previously recognized. The mechanisms of these associations may be bidirectional and deserve further study. © 2014 American Heart Association, Inc.
Synchronization for Optical PPM Signals
NASA Technical Reports Server (NTRS)
Vilnrotter, V. A.
1985-01-01
Method based on statistical properties of weak pulse-positionmodulated (PPM) signal enables synchronization of receiver clock with received-signal time base. Method applies to weak optical M-ary PPM signals, for which there is only one pulse of length Tp transmitted during one of timeslots of length T in each successive interval of M timeslots. Method requires small dead time, Td, at beginning and end of each timeslot, during which pulse amplitude is zero.
Kaszuba-Zwoinska, J; Chorobik, P; Juszczak, K; Zaraska, W; Thor, P J
2012-10-01
Current studies were aimed to elucidate influence of pulsed electromagnetic field stimulation on cell viability and apoptosis induction pathways. For the experimental model we have chosen monocytic cell line MonoMac6 and several apoptosis inducers with different mechanism of death induction like puromycin, colchicine, cyclophosphamide, minocycline and hydrogen peroxide. MonoMac6 cell line was grown at density 1x10(5) cells/well in 96-well culture plates. To induce cell death cell cultures were treated with different apoptosis inducers like puromycin, colchicine, cyclophosphamide, minocycline, hydrogen peroxide and at the same time with pulsed electromagnetic field 50 Hz, 45±5 mT (PEMF) for 4 hour per each stimulation, three times, in 24 hours intervals. Afterwards, cells were harvested for flow cytometry analysis of cell viability measured by annexin V-APC labeled and propidium iodide staining. Expression of apoptosis related genes was evaluated by semi quantitative reverse transcription (RT)-PCR assay. NuPAGE Novex Western blot analysis was carried out for apoptosis inducing factor (AIF) abundance in cytosolic and nuclear extracts of MonoMac6 cells. Puromycin, colchicine and minocycline activated cells and simultaneously treated with PEMF have shown out diminished percentage of annexinV positive (AnV+) cells comparing to controls without PEMF stimulation. MonaMac6 cells puromycin/colchicyne and PEMF treated were to a higher extent double stained (AnV+,PI+), which means increased late apoptotic as well as necrotic (PI+) cells, than non-stimulated controls. On the other hand, minocycline activated cells prior to PEMF treatment showed diminished amount of apoptotic and necrotic (annexin V, annexin V and propidium iodide, propidium iodide positive staining) cells. The opposite effect of PEMF on the percentage of annexin V positively stained cells has been achieved after treatment of MonoMac6 culture with cyclophoshamide and hydrogen peroxide. PEMF enhanced early phase of apoptosis induced by both apoptosis inducing agents. The analysis of expression of the apoptosis related genes in MonoMac6 cultures treated with puromycin and exposed to PEMF performed in reverse transcription of polymerase chain reaction (PCR) assay has shown changes in mRNA of genes engaged in intrinsic apoptotic pathway and pathway with AIF abundance. The most influenced was expression of gene belonging to pro-apoptotic family of Bcl-2 and AIF agent. Examination of immunoblots developed with anti-AIF antibody showed that cytosol content of AIF protein was diminished after puromycin and PEMF treatment of MonoMac6 cells. The obtained results indicate that PEMF affects induction of apoptosis in MonoMac6 cells stimulated to death with inducing agents to a different extent. Main finding of the current results is that, PEMF stimulation of MonoMac6 cells simultaneously treated with puromycin caused changes in the Bcl-family genes expression as well as in caspase independent pathway of apoptosis inducing factor (AIF).
Physical Modeling Techniques for Missile and Other Protective Structures
1983-06-29
uniaxial load only. In general , axial thrust was applied with an: initial eccentricity of zero on the specimen end. Sixteen different combinations of Pa...conditioning electronics and cabling schemes is included. The techniques described generally represent current approaches at the Civil Engineering Research...at T- zero and stopping when a pulse is generated by the pi-ezoelectric disc on arrival of! the detonation wave front. All elapsed time data is stored
Lefferts, W K; Hughes, W E; Heffernan, K S
2015-12-01
Exertional hypertension associated with acute high-intensity resistance exercise (RE) increases both intravascular and intracranial pressure (ICP), maintaining cerebrovascular transmural pressure. Carotid intravascular pressure pulsatility remains elevated after RE. Whether ICP also remains elevated after acute RE in an attempt to maintain the vessel wall transmural pressure is unknown. Optic nerve sheath diameter (ONSD), a valid proxy of ICP, was measured in 20 participants (6 female; 24 ± 4 yr, 24.2 ± 3.9 kg m(-)(2)) at rest (baseline), following a time-control condition, and following RE (5 sets, 5 repetition maximum bench press, 5 sets 10 repetition maximum biceps curls) using ultrasound. Additionally, intracranial hemodynamic pulsatility index (PI) was assessed in the ophthalmic artery (OA) by using Doppler. Aortic pulse wave velocity (PWV) was obtained from synthesized aortic pressure waveforms obtained via a brachial oscillometric cuff and carotid pulse pressure was measured by using applanation tonometry. Aortic PWV (5.2 ± 0.5-6.0 ± 0.7 m s(-1), P < 0.05) and carotid pulse pressure (45 ± 17-59 ± 19 mm Hg, P < 0.05) were significantly elevated post RE compared with baseline. There were no significant changes in ONSD (5.09 ± 0.7-5.09 ± 0.7 mm, P > 0.05) or OA flow PI (1.35 ± 0.2-1.38 ± 0.3, P > 0.05) following acute RE. In conclusion, during recovery from acute high-intensity RE, there are increases in aortic stiffness and extracranial pressure pulsatility in the absence of changes in ICP and flow pulsatility. These findings may have implications for alterations in cerebral transmural pressure and cerebral aneurysmal wall stress following RE.
Influence of angular acceleration-deceleration pulse shapes on regional brain strains.
Yoganandan, Narayan; Li, Jianrong; Zhang, Jiangyue; Pintar, Frank A; Gennarelli, Thomas A
2008-07-19
Recognizing the association of angular loading with brain injuries and inconsistency in previous studies in the application of the biphasic loads to animal, physical, and experimental models, the present study examined the role of the acceleration-deceleration pulse shapes on region-specific strains. An experimentally validated two-dimensional finite element model representing the adult male human head was used. The model simulated the skull and falx as a linear elastic material, cerebrospinal fluid as a hydrodynamic material, and cerebrum as a linear viscoelastic material. The angular loading matrix consisted coronal plane rotation about a center of rotation that was acceleration-only (4.5 ms duration, 7.8 krad/s/s peak), deceleration-only (20 ms, 1.4 krad/s/s peak), acceleration-deceleration, and deceleration-acceleration pulses. Both biphasic pulses had peaks separated by intervals ranging from 0 to 25 ms. Principal strains were determined at the corpus callosum, base of the postcentral sulcus, and cerebral cortex of the parietal lobe. The cerebrum was divided into 17 regions and peak values of average maximum principal strains were determined. In all simulations, the corpus callosum responded with the highest strains. Strains were the least under all simulations in the lower parietal lobes. In all regions peak strains were the same for both monophase pulses suggesting that the angular velocity may be a better metric than peak acceleration or deceleration. In contrast, for the biphasic pulse, peak strains were region- and pulse-shape specific. Peak values were lower in both biphasic pulses when there was no time separation between the pulses than the corresponding monophase pulse. Increasing separation time intervals increased strains, albeit non-uniformly. Acceleration followed by deceleration pulse produced greater strains in all regions than the other form of biphasic pulse. Thus, pulse shape appears to have an effect on regional strains in the brain.
Resolving semantic and proactive interference in memory over the short-term.
Atkins, Alexandra S; Berman, Marc G; Reuter-Lorenz, Patricia A; Lewis, Richard L; Jonides, John
2011-07-01
Interference is a major source of short-term errors of memory. The present investigation explores the relationship between two important forms of interference: proactive interference (PI), induced by the need to reject recently studied items no longer relevant to task performance, and semantic interference (SI), induced by the need to reject lures sharing a meaningful relationship with current memoranda. We explore the possibility that shared cognitive control processes are recruited to resolve both forms of interference. In Experiment 1, we find that the requirement to engage in articulatory suppression during the retention interval of tasks that induce either PI or SI increases both forms of interference similarly and selectively. In Experiment 2, we develop a task to examine PI and SI within the same experimental context. The results show interactive effects between factors that lead to the two forms of interference. Taken together, these findings support contextual-cuing models of short-term remembering (Nairne, Annual Review of Psychology, 53, 53-81 2002), where the context in which retrieval occurs can influence susceptibility to interference. Lastly, we discuss several theoretical hypotheses concerning the cognitive control processes that are recruited to resolve SI and PI in short-term remembering.
Resolving semantic and proactive interference in memory over the short-term
Reuter-Lorenz, Patricia A.; Lewis, Richard L.; Jonides, John
2011-01-01
Interference is a major source of short-term errors of memory. The present investigation explores the relationship between two important forms of interference: proactive interference (PI), induced by the need to reject recently studied items no longer relevant to task performance, and semantic interference (SI), induced by the need to reject lures sharing a meaningful relationship with current memoranda. We explore the possibility that shared cognitive control processes are recruited to resolve both forms of interference. In Experiment 1, we find that the requirement to engage in articulatory suppression during the retention interval of tasks that induce either PI or SI increases both forms of interference similarly and selectively. In Experiment 2, we develop a task to examine PI and SI within the same experimental context. The results show interactive effects between factors that lead to the two forms of interference. Taken together, these findings support contextual-cuing models of short-term remembering (Nairne, Annual Review of Psychology, 53, 53–81 2002), where the context in which retrieval occurs can influence susceptibility to interference. Lastly, we discuss several theoretical hypotheses concerning the cognitive control processes that are recruited to resolve SI and PI in short-term remembering. PMID:21327614
Modelling the effect of pyrethroid use intensity on mite population density for walnuts.
Zhan, Yu; Fan, Siqi; Zhang, Minghua; Zalom, Frank
2015-01-01
Published studies relating pyrethroid use and subsequent mite outbreaks have largely been based on laboratory and field experiments, with some inferring a result of increased miticide use. The present study derived a mathematical model proposed to quantify the effect of pyrethroid use intensity on mite population density. The model was validated against and parameterized with actual field-level pyrethroid and miticide use data from 1995 to 2009 for California walnuts, where the miticide use intensity was a proxy of the mite population density. The parameterized model was MI = 1.61 - 0.89 · exp(-93.31PI) (RMSE = 0.13; R(2) = 0.69; P < 0.01), where PI and MI are the average pyrethroid and miticide use intensity in small intervals respectively. A three-range scheme was presented to quantify pesticide applications based on the change rate of MI to PI. Specific for California walnuts, the PI range of 0-0.025 kg ha(-1) was identified as the rapidly increasing range where MI increased vastly when PI increased. Results confirmed that more miticide was used, presumably to prevent or control mite resurgence when pyrethroids were applied, a practice that is not only costly but might be expected to aggravate mite resistance to miticides and increase risk associated with these chemicals to the environment and human health. © 2014 Society of Chemical Industry.
Ponderal index at birth associates with later risk of gestational diabetes mellitus.
Crusell, Mie; Damm, Peter; Hansen, Torben; Pedersen, Oluf; Glümer, Charlotte; Vaag, Allan; Lauenborg, Jeannet
2017-08-01
Low birth weight (BW) and low ponderal index (PI) are associated with increased risk of type 2 diabetes mellitus. This study has two purposes: first to investigate the influence of PI on the risk of gestational diabetes mellitus (GDM); second, to study the association between glucose metabolism and BW in women with previous GDM. GDM cohort: 185 women with GDM in 1978-1996, attending a follow-up study in 2000-2002. Control cohort: 1137 women from a population-based diabetes screening study (Inter99) in a neighbouring county in 1999-2001. BW and birth length were collected from the original midwifery records. BW and PI were stratified into tertiles for analysis. PI in the lower tertiles was associated with an increased risk of GDM [odds ratio 1.59 (95% confidence interval 1.07-2.36, p = 0.021)]. Among women with previous GDM, the area under the curve (AUC) for plasma levels of glucose and insulin during an OGTT was highest for the lower tertiles of BW (for AUCglucose p = 0.048, for AUCinsulin p = 0.047 adjusted for age and BMI). Lower PI is associated with increased risk of GDM. In women with previous GDM, lower BW is associated with a more severe impairment of glucose metabolism one to two decades after the pregnancy complicated by GDM.
High Glucose Impairs Insulin Signaling in the Glomerulus: An In Vitro and Ex Vivo Approach
Katsoulieris, Elias N.; Drossopoulou, Garyfalia I.; Kotsopoulou, Eleni S.; Vlahakos, Dimitrios V.; Lianos, Elias A.; Tsilibary, Effie C.
2016-01-01
Objective Chronic hyperglycaemia, as seen in type II diabetes, results in both morphological and functional impairments of podocytes in the kidney. We investigated the effects of high glucose (HG) on the insulin signaling pathway, focusing on cell survival and apoptotic markers, in immortalized human glomerular cells (HGEC; podocytes) and isolated glomeruli from healthy rats. Methods and Findings HGEC and isolated glomeruli were cultured for various time intervals under HG concentrations in the presence or absence of insulin. Our findings indicated that exposure of HGEC to HG led to downregulation of all insulin signaling markers tested (IR, p-IR, IRS-1, p-Akt, p-Fox01,03), as well as to increased sensitivity to apoptosis (as seen by increased PARP cleavage, Casp3 activation and DNA fragmentation). Short insulin pulse caused upregulation of insulin signaling markers (IR, p-IR, p-Akt, p-Fox01,03) in a greater extent in normoglycaemic cells compared to hyperglycaemic cells and for the case of p-Akt, in a PI3K-dependent manner. IRS-1 phosphorylation of HG-treated podocytes was negatively regulated, favoring serine versus tyrosine residues. Prolonged insulin treatment caused a significant decrease of IR levels, while alterations in glucose concentrations for various time intervals demonstrated changes of IR, p-IR and p-Akt levels, suggesting that the IR signaling pathway is regulated by glucose levels. Finally, HG exerted similar effects in isolated glomeruli. Conclusions These results suggest that HG compromises the insulin signaling pathway in the glomerulus, promoting a proapoptotic environment, with a possible critical step for this malfunction lying at the level of IRS-1 phosphorylation; thus we herein demonstrate glomerular insulin signaling as another target for investigation for the prevention and/ or treatment of diabetic nephropathy. PMID:27434075
Buhusi, Catalin V.; Lamoureux, Jeffrey A.; Meck, Warren H.
2008-01-01
The effects of prenatal choline availability on contextual processing in a 30-s peak-interval (PI) procedure with gaps (1, 5, 10, and 15 s) were assessed in adult male rats. Neither supplementation nor deprivation of prenatal choline affected baseline timing performance in the PI procedure. However, prenatal choline availability significantly altered the contextual processing of gaps inserted into the to-be-timed signal (light on). Choline-supplemented rats displayed a high degree of context sensitivity as indicated by clock resetting when presented with a gap in the signal (light off). In contrast, choline-deficient rats showed no such effect and stopped their clocks during the gap. Control rats exhibited an intermediate level of contextual processing in between stop and full reset. When switched to a reversed gap condition in which rats timed the absence of the light and the presence of the light served as a gap, all groups reset their clocks following a gap. Furthermore, when filling the intertrial interval (ITI) with a distinctive stimulus (e.g., sound), both choline-supplemented and control rats rightward shifted their PI functions less on trials with gaps than choline-deficient rats, indicating greater contextual sensitivity and reduced clock resetting under these conditions. Overall, these data support the view that prenatal choline availability affects the sensitivity to the context in which gaps are inserted in the to-be-timed signal, thereby influencing whether rats run, stop, or reset their clocks. PMID:18778696
A digital acquisition and elaboration system for nuclear fast pulse detection
NASA Astrophysics Data System (ADS)
Esposito, B.; Riva, M.; Marocco, D.; Kaschuck, Y.
2007-03-01
A new digital acquisition and elaboration system has been developed and assembled in ENEA-Frascati for the direct sampling of fast pulses from nuclear detectors such as scintillators and diamond detectors. The system is capable of performing the digital sampling of the pulses (200 MSamples/s, 14-bit) and the simultaneous (compressed) data transfer for further storage and software elaboration. The design (FPGA-based) is oriented to real-time applications and has been developed in order to allow acquisition with no loss of pulses and data storage for long-time intervals (tens of s at MHz pulse count rates) without the need of large on-board memory. A dedicated pulse analysis software, written in LabVIEWTM, performs the treatment of the acquired pulses, including pulse recognition, pile-up rejection, baseline removal, pulse shape particle separation and pulse height spectra analysis. The acquisition and pre-elaboration programs have been fully integrated with the analysis software.
Raspberry Pi camera with intervalometer used as crescograph
NASA Astrophysics Data System (ADS)
Albert, Stefan; Surducan, Vasile
2017-12-01
The intervalometer is an attachment or facility on a photo-camera that operates the shutter regularly at set intervals over a period. Professional cameras with built in intervalometers are expensive and quite difficult to find. The Canon CHDK open source operating system allows intervalometer implementation on Canon cameras only. However finding a Canon camera with near infra-red (NIR) photographic lens at affordable price is impossible. On experiments requiring several cameras (used to measure growth in plants - the crescographs, but also for coarse evaluation of the water content of leaves), the costs of the equipment are often over budget. Using two Raspberry Pi modules each equipped with a low cost NIR camera and a WIFI adapter (for downloading pictures stored on the SD card) and some freely available software, we have implemented two low budget intervalometer cameras. The shutting interval, the number of pictures to be taken, image resolution and some other parameters can be fully programmed. Cameras have been in use continuously for three months (July-October 2017) in a relevant environment (outside), proving the concept functionality.
Distributed fiber sparse-wideband vibration sensing by sub-Nyquist additive random sampling
NASA Astrophysics Data System (ADS)
Zhang, Jingdong; Zheng, Hua; Zhu, Tao; Yin, Guolu; Liu, Min; Bai, Yongzhong; Qu, Dingrong; Qiu, Feng; Huang, Xianbing
2018-05-01
The round trip time of the light pulse limits the maximum detectable vibration frequency response range of phase-sensitive optical time domain reflectometry ({\\phi}-OTDR). Unlike the uniform laser pulse interval in conventional {\\phi}-OTDR, we randomly modulate the pulse interval, so that an equivalent sub-Nyquist additive random sampling (sNARS) is realized for every sensing point of the long interrogation fiber. For an {\\phi}-OTDR system with 10 km sensing length, the sNARS method is optimized by theoretical analysis and Monte Carlo simulation, and the experimental results verify that a wide-band spars signal can be identified and reconstructed. Such a method can broaden the vibration frequency response range of {\\phi}-OTDR, which is of great significance in sparse-wideband-frequency vibration signal detection, such as rail track monitoring and metal defect detection.
Development of microcontroller based water flow measurement
NASA Astrophysics Data System (ADS)
Munir, Muhammad Miftahul; Surachman, Arif; Fathonah, Indra Wahyudin; Billah, Muhammad Aziz; Khairurrijal, Mahfudz, Hernawan; Rimawan, Ririn; Lestari, Slamet
2015-04-01
A digital instrument for measuring water flow was developed using an AT89S52 microcontroller, DS1302 real time clock (RTC), and EEPROM for an external memory. The sensor used for probing the current was a propeller that will rotate if immersed in a water flow. After rotating one rotation, the sensor sends one pulse and the number of pulses are counted for a certain time of counting. The measurement data, i.e. the number of pulses per unit time, are converted into water flow velocity (m/s) through a mathematical formula. The microcontroller counts the pulse sent by the sensor and the number of counted pulses are stored into the EEPROM memory. The time interval for counting is provided by the RTC and can be set by the operator. The instrument was tested under various time intervals ranging from 10 to 40 seconds and several standard propellers owned by Experimental Station for Hydraulic Structure and Geotechnics (BHGK), Research Institute for Water Resources (Pusair). Using the same propellers and water flows, it was shown that water flow velocities obtained from the developed digital instrument and those found by the provided analog one are almost similar.
Birch, K; Hildebrandt, P; Jensen, B M; Kühl, C; Brange, J
1985-05-01
To compare the metabolic control and the pharmacokinetics of infused insulin using an insulin pump (Auto-Syringe AS 6C) which provides the basal rate in pulses every 2-10 min with a pump (Medix Syringe Driver 209) providing the basal rate in pulses every 15-60 min, 6 C-peptide negative diabetic patients received, in random order, identical, but individual, insulin treatment during one 4-day period using the Auto-Syringe pump and another 4-day period using the Medix pump. On the fourth day of each period, blood glucose and plasma-free insulin were estimated every 30 min for 7 hr and every 5 min for the next hour. Plasma-free insulin was significantly higher on 3 time points out of the 26 possible when using the Medix pump, but this was not reflected in the blood glucose concentrations which were similar in the 2 periods. The results indicate that, from a metabolic and pharmacokinetic point of view, insulin pumps working with larger intervals between the basal rate pulses are just as good as the more technically advanced and hence often more expensive pumps which provide the basal rate in more and smaller pulses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khakoo, M.A.; Ozkay, I.; Johnson, P.V.
2005-06-15
Measurements of differential cross sections for the electron-impact excitation of molecular nitrogen from the ground X {sup 1}{sigma}{sub g}{sup +}(v{sup ''}=0) level to the A {sup 3}{sigma}{sub u}{sup +}(v{sup '}), B {sup 3}{pi}{sub g}(v{sup '}), W {sup 3}{delta}{sub u}(v{sup '}), B{sup '} {sup 3}{sigma}{sub u}{sup -}(v{sup '}), a{sup '} {sup 1}{sigma}{sub u}{sup -}(v{sup '}), a {sup 1}{pi}{sub g}(v{sup '}), w {sup 1}{delta}{sub u}(v{sup '}), and C {sup 3}{pi}{sub u}(v{sup '}) levels are presented. The data are obtained at the incident energies of 10, 12.5, 15, 17.5, 20, 30, 50, and 100 eV over the angular range of 5 deg. -130more » deg. in 5 deg. intervals. The individual electronic state excitation differential cross sections are obtained by unfolding electron energy-loss spectra of molecular nitrogen using available semiempirical Frank-Condon factors. The data are compared to previous measurements and to available theory. We also make several important suggestions regarding future work that, like the present, relies on the unfolding of electron energy-loss spectra for obtaining differential cross sections.« less
Demers, Marie-Elaine; Dubé, Samuel; Bourdages, Mélodie; Gasse, Cedric; Boutin, Amélie; Girard, Mario; Bujold, Emmanuel; Demers, Suzanne
2018-01-10
To compare the first-trimester uterine artery pulsatility index (PI) measured by abdominal and transvaginal ultrasound (US). We performed a prospective study of singleton pregnant women recruited at 11 to 13 weeks' gestation. The mean uterine artery PI was obtained by abdominal followed by transvaginal US. The mean of the left and right uterine artery PIs was used, and differences between approaches were computed. The intraclass correlation coefficient and a Bland-Altman plot were used to compare the two approaches. Data were available for 940 participants, including 928 (99%) with uterine artery PIs obtained on both uterine sides. The mean uterine artery PI decreased with gestational age in both approaches (P < .001). We observed a moderate correlation between abdominal and transvaginal mean uterine artery PIs (intraclass correlation coefficient, 0.72; 95% confidence interval, 0.69 to 0.75). Values obtained by abdominal US (median, 1.70, interquartile range, 1.35 to 2.09) were greater than those obtained by transvaginal US (median, 1.65; interquartile range, 1.37 to 1.99). There was a significant increase in differences as average measurements became higher (P < .01). The first-trimester mean uterine artery PI decreases with gestational age in both approaches. Abdominal US could be associated with greater uterine artery PI values than transvaginal US, especially at higher measurements. The first-trimester uterine artery PI for prediction of adverse perinatal outcomes should be adjusted for gestational age and possibly for the US approach. © 2018 by the American Institute of Ultrasound in Medicine.
Ma, Wenjuan; Chen, Renjie; Kan, Haidong
2014-10-01
Few multicity studies have been conducted to investigate the acute health effects of cold and hot temperatures in China. We aimed to examine the relationship between temperature and daily mortality in 17 large Chinese cities. We first calculated city-specific effect of temperature using time-series regression models combined with distributed lag nonlinear models; then we pooled the city-specific estimates with the Bayesian hierarchical models. The cold effects lasted longer than the hot effects. For the cold effects, a 1 °C decrease from the 25th to 1st percentiles of temperature over lags 0-14 days was associated with increases of 1.69% [95% posterior intervals (PI): 1.01%, 2.36%], 2.49% (95% PI: 1.53%, 3.46%) and 1.60% (95% PI: 0.32%, 2.87%) in total, cardiovascular and respiratory mortality, respectively. For the hot effects, a 1 °C increase from the 75th to 99th percentiles of temperature was associated with corresponding increases of 2.83% (95% PI: 1.42%, 4.24%), 3.02% (95% PI: 1.33%, 4.71%) and 4.64% (95% PI: 1.96%, 7.31%). The latitudes, number of air conditioning per household and disposable income per capita were significant modifiers for cold effects; the proportion of the elderly was a significant modifier for hot effects. This largest epidemiological study of temperature to date in China suggested that both cold and hot temperatures were associated with increased mortality. Our findings may have important implications for the public health policies in China. Copyright © 2014 Elsevier Inc. All rights reserved.
Programmable random interval generator
NASA Technical Reports Server (NTRS)
Lindsey, R. S., Jr.
1973-01-01
Random pulse generator can supply constant-amplitude randomly distributed pulses with average rate ranging from a few counts per second to more than one million counts per second. Generator requires no high-voltage power supply or any special thermal cooling apparatus. Device is uniquely versatile and provides wide dynamic range of operation.
Characteristics of an actuator-driven pulsed water jet generator to dissecting soft tissue.
Seto, Takeshi; Yamamoto, Hiroaki; Takayama, Kazuyoshi; Nakagawa, Atsuhiro; Tominaga, Teiji
2011-05-01
This paper reports characteristics of an actuator-driven pulsed water jet generator applied, in particular, to dissect soft tissues. Results of experiments, by making use of high speed recording of optical visualization and varying nozzle diameter, actuator time interval, and their effects on dissection performance are presented. Jet penetration characteristics are compared with continuous water jet and hence potential assessment of pulsed water jets to clinical applications is performed.
Generation of Gigawatt Circularly Polarized Attosecond-Pulse Pairs
NASA Astrophysics Data System (ADS)
Hu, K.; Wu, H.-C.
2017-12-01
A novel scheme for generating a pair of gigawatt attosecond pulses by coherent Thomson scattering from relativistic electron sheets is proposed. With a circularly polarized relativistic laser pulse, the scattered x-ray signal can have a saddlelike temporal profile, where the lower electromagnetic frequencies are found mostly in the center region of this saddlelike profile. By filtering out the latter, we can obtain two few-attosecond pulses separated by a subfemtosecond interval, which is tunable by controlling the energy of the sheet electrons. Such a pulse pair can be useful for an attosecond pump probe at an unprecedented time resolution and for ultrafast chiral studies in molecules and materials.
Joksimovic, Boban; Szelenyi, Andrea; Seifert, Volker; Damjanovic, Aleksandar; Damjanovic, Aleksandra; Rasulic, Lukas
2015-05-01
To evaluate the relationship between stimulus intensity by constant current transcranial electric stimulation and interstimulus interval (ISI) for eliciting muscle motor evoked potentials (MEPs) in three different hand muscles and the tibialis anterior muscles. We tested intraoperatively different monophasic constant current pulses and ISIs in 22 patients with clinically normal motor function. Motor thresholds of contralateral muscle MEPs were determined at 0.5 milliseconds (ms) pulse duration and ISIs of 1, 2, 3, 4, 5, and 10 ms using a train of 2, 3, and 5 monophasic constant current pulses of 62 to 104 mA before craniotomy and after closure of the dura mater. The lowest stimulation threshold to elicit MEPs in the examined muscles was achieved with a train of 5 pulses (ISI: 3 ms) before craniotomy, which was statistically significant compared with 2 pulses (ISI: 3 ms) as well as 3 pulses (ISIs: 3 and 10 ms). An ISI of 3 ms gave the lowest motor thresholds with statistical significance compared with the ISIs of 4 ms (2 pulses) and of 1 ms (3 pulses). All current intensity (mA) and ISI (ms) relationship graphs had a trend of the exponential function as y = a + bx + c ρ (x), where y is intensity (mA) and x is ISI (ms). The minimum of the function was determined for each patient and each muscle. The difference was statistically significant between 3 and 5 pulses before craniotomy and between 3 and 5 pulses and 2 and 5 pulses after closure of the dura mater. In adult neurosurgical patients with a normal motor status, a train of 5 pulses and an ISI of 3 ms provide the lowest motor thresholds. We provided evidence of the dependence of required stimulation current on ISI. Georg Thieme Verlag KG Stuttgart · New York.
Resonant Pump-dump Quantum Control of Solvated Dye Molecules with Phase Jumps
NASA Astrophysics Data System (ADS)
Konar, Arkaprabha; Lozovoy, Vadim; Dantus, Marcos
2014-03-01
Quantum coherent control of two photon and multiphoton excitation processes in atomic and condensed phase systems employing phase jumps has been well studied and understood. Here we demonstrate coherent quantum control of a two photon resonant pump-dump process in a complex solvated dye molecule. Phase jump in the frequency domain via a pulse shaper is employed to coherently enhance the stimulated emission by an order of magnitude when compared to transform limited pulses. Red shifted stimulated emission from successive low energy Stokes shifted excited states leading to narrowband emission are observed upon scanning the pi step across the excitation spectrum. A binary search space routine was also employed to investigate the effects of other types of phase jumps on stimulated emission and to determine the optimum phase that maximizes the emission. Understanding the underlying mechanism of this kind of enhancement will guide us in designing pulse shapes for enhancing stimulated emission, which can be further applied in the field of imaging.
NASA Astrophysics Data System (ADS)
Zhang, Jie; Tao, Sha; Wang, Brian; Zhao, Jay
2016-03-01
In this paper, laser ablation of widely used metal (Al, Cu. stainless-steel), semiconductor (Si), transparent material (glass, sapphire), ceramic (Al2O3, AlN) and polymer (PI, PMMA) in industry were systematically studied with pulse width from nanosecond (5-100ns), picosecond (6-10ps) to sub-picosecond (0.8-0.95ps). A critical damage zone (CDZ) of up to 100um with ns laser, <=50um with ps laser, and <=20um with sub-ps laser, respectively was observed as a criteria of selecting the laser pulse width. The effects of laser processing parameters on speed and efficiency were also investigated. This is to explore how to provide industry users the best laser solution for device micro-fabrication with best price. Our studies of cutting and drilling with ns, ps, and sub-ps lasers indicate that it is feasible to achieve user accepted quality and speed with cost-effective and reliable laser by optimizing processing conditions.
Association between glutathione S-transferase pi genetic polymorphisms and oral cancer risk.
Park, J Y; Schantz, S P; Stern, J C; Kaur, T; Lazarus, P
1999-08-01
Polymorphisms in the gene encoding the glutathione S-transferase (GST) pi metabolizing enzyme have previously been associated with susceptibility to various cancers. In this study, the importance of GSTP1 genotypes as determinants of risk for oral cancer was assessed by examining the prevalence of GSTP1 alleles in 157 incident oral cancer cases and 260 non-cancer control individuals frequency-matched by race, sex, and age at diagnosis (+/- 5 years). The GSTP1*A, GSTP1*B, GSTP1*C, and GSTP1*D alleles were elucidated by polymerase chain reaction-restriction fragment length polymorphism analysis of polymorphisms present in codons 105 (isoleucine:valine) and 114 (alanine:valine) of the GSTP1 gene. Increased risk for oral cancer was observed in individuals who were homozygous for any combination of GSTP1 polymorphic alleles (i.e. *B, *C, and/or *D alleles; odds ratio = 2.4, 95% confidence interval = 1.2-4.8). Similar risk was observed in both Caucasians (odds ratio = 2.6, 95% confidence interval = 1.1-6.2) and African-Americans (odds ratio = 2.3, 95% CI = 0.68-7.5). A greater risk was observed in individuals with the GSTP1 (Var/Var) genotype who were exposed to low levels of smoking (i.e. < or = 20 pack-years [py], odds ratio = 3.4, 95% confidence interval = 1.1-11) than among heavier smokers (i.e. > 20 pack-years [py], odds ratio = 1.4, 95% confidence interval = 0.48-4.0). These results suggest that GSTP1 genotype may play a role in risk for oral cancer particularly among lighter smokers.
Characteristic pulse trains of preliminary breakdown in four isolated small thunderstorms
NASA Astrophysics Data System (ADS)
Ma, Dong
2017-03-01
Using a low-frequency six-station local network, preliminary breakdown (PB) pulses not followed or followed by negative return stroke (RS), which are defined as PB-type and PB cloud-to-ground (PBCG)-type flashes, are analyzed based on four isolated small thunderstorms for the first time. On the basis of 22 PB-type flashes out of totally 2155 flashes, it indicates that the number of PB-type flashes is very small. At the early stage, PB-type flashes are observed in all four thunderstorms. At the active stage, PB-type flashes still can occur; meanwhile, there are few or no negative cloud-to-ground (CG) flashes. However, at the final stage no PB-type flashes occur. At the stage of distinct cell merging or splitting, PB-type flashes are also observed. Based on the 123 PBCG-type flashes, we discuss the percentage of PBCG-type flashes and also analyze the relationship between the electric field (E-field) amplitude of the largest pulse in the PB pulse train normalized to 100 km (PBA), the E-field amplitude of the first return stroke normalized to 100 km (RSA), the time interval between PBA and RSA (PB-RS interval), and the ratio between PBA and RSA (PB-RS ratio). We find that the percentage of PBCG-type flashes is not always dependent on PBA or PB-RS ratio; the type of thunderstorms may also have an impact on this percentage. None of the PB-RS intervals is less than 20 ms; we speculate that such long PB-RS interval is the feature of isolated small thunderstorms, but more observations are needed to further investigate this question.
Shaikh, Amir Y; Wang, Na; Yin, Xiaoyan; Larson, Martin G; Vasan, Ramachandran S; Hamburg, Naomi M; Magnani, Jared W; Ellinor, Patrick T; Lubitz, Steven A; Mitchell, Gary F; Benjamin, Emelia J; McManus, David D
2016-09-01
The relations of measures of arterial stiffness, pulsatile hemodynamic load, and endothelial dysfunction to atrial fibrillation (AF) remain poorly understood. To better understand the pathophysiology of AF, we examined associations between noninvasive measures of vascular function and new-onset AF. The study sample included participants aged ≥45 years from the Framingham Heart Study offspring and third-generation cohorts. Using Cox proportional hazards regression models, we examined relations between incident AF and tonometry measures of arterial stiffness (carotid-femoral pulse wave velocity), wave reflection (augmentation index), pressure pulsatility (central pulse pressure), endothelial function (flow-mediated dilation), resting brachial arterial diameter, and hyperemic flow. AF developed in 407/5797 participants in the tonometry sample and 270/3921 participants in the endothelial function sample during follow-up (median 7.1 years, maximum 10 years). Higher augmentation index (hazard ratio, 1.16; 95% confidence interval, 1.02-1.32; P=0.02), baseline brachial artery diameter (hazard ratio, 1.20; 95% confidence interval, 1.01-1.43; P=0.04), and lower flow-mediated dilation (hazard ratio, 0.79; 95% confidence interval, 0.63-0.99; P=0.04) were associated with increased risk of incident AF. Central pulse pressure, when adjusted for age, sex, and hypertension (hazard ratio, 1.14; 95% confidence interval, 1.02-1.28; P=0.02) was associated with incident AF. Higher pulsatile load assessed by central pulse pressure and greater apparent wave reflection measured by augmentation index were associated with increased risk of incident AF. Vascular endothelial dysfunction may precede development of AF. These measures may be additional risk factors or markers of subclinical cardiovascular disease associated with increased risk of incident AF. © 2016 American Heart Association, Inc.
Pulsed electromagnetic fields promote survival and neuronal differentiation of human BM-MSCs.
Urnukhsaikhan, Enerelt; Cho, Hyunjin; Mishig-Ochir, Tsogbadrakh; Seo, Young-Kwon; Park, Jung-Kueg
2016-04-15
Pulsed electromagnetic fields (PEMF) are known to affect biological properties such as differentiation, regulation of transcription factor and cell proliferation. However, the cell-protective effect of PEMF exposure is largely unknown. The aim of this study is to understand the mechanisms underlying PEMF-mediated suppression of apoptosis and promotion of survival, including PEMF-induced neuronal differentiation. Treatment of induced human BM-MSCs with PEMF increased the expression of neural markers such as NF-L, NeuroD1 and Tau. Moreover, treatment of induced human BM-MSCs with PEMF greatly decreased cell death in a dose- and time-dependent manner. There is evidence that Akt and Ras are involved in neuronal survival and protection. Activation of Akt and Ras results in the regulation of survival proteins such as Bad and Bcl-xL. Thus, the Akt/Ras signaling pathway may be a desirable target for enhancing cell survival and treatment of neurological disease. Our analyses indicated that PEMF exposure dramatically increased the activity of Akt, Rsk, Creb, Erk, Bcl-xL and Bad via phosphorylation. PEMF-dependent cell protection was reversed by pretreatment with LY294002, a specific inhibitor of phosphatidylinositol 3-kinase (PI3K). Our data suggest that the PI3K/Akt/Bad signaling pathway may be a possible mechanism for the cell-protective effects of PEMF. Copyright © 2016 Elsevier Inc. All rights reserved.
Shankar, Prasad R; Kaza, Ravi K; Al-Hawary, Mahmoud M; Masch, William R; Curci, Nicole E; Mendiratta-Lala, Mishal; Sakala, Michelle D; Johnson, Timothy D; Davenport, Matthew S
2018-04-17
Purpose To assess the impact of clinical history on the maximum Prostate Imaging Recording and Data System (PI-RADS) version 2 (v2) score assigned to multiparametric magnetic resonance (MR) imaging of the prostate. Materials and Methods This retrospective cohort study included 120 consecutively selected multiparametric prostate MR imaging studies performed between November 1, 2016, and December 31, 2016. Sham clinical data in four domains (digital rectal examination, prostate-specific antigen level, plan for biopsy, prior prostate cancer history) were randomly assigned to each case by using a balanced orthogonal design. Six fellowship-trained abdominal radiologists independently reviewed the sham data, actual patient age, and each examination while they were blinded to interreader scoring, true clinical data, and histologic findings. Readers were told the constant sham histories were true, believed the study to be primarily investigating interrater agreement, and were asked to assign a maximum PI-RADS v2 score to each case. Linear regression was performed to assess the association between clinical variables and maximum PI-RADS v2 score designation. Intraclass correlation coefficients (ICCs) were obtained to compare interreader scoring. Results Clinical information had no significant effect on maximum PI-RADS v2 scoring for any of the six readers (P = .09-.99, 42 reader-variable pairs). Distributions of maximum PI-RADS v2 scores in the research context were similar to the distribution of the scores assigned clinically and had fair-to-excellent pairwise interrater agreement (ICC range: 0.53-0.76). Overall interrater agreement was good (ICC: 0.64; 95% confidence interval: 0.57, 0.71). Conclusion Clinical history does not appear to be a substantial bias in maximum PI-RADS v2 score assignment. This is potentially important for clinical nomograms that plan to incorporate PI-RADS v2 score and clinical data into their algorithms (ie, PI-RADS v2 scoring is not confounded by clinical data). © RSNA, 2018 Online supplemental material is available for this article.
Approximation Algorithms for the Highway Problem under the Coupon Model
NASA Astrophysics Data System (ADS)
Hamane, Ryoso; Itoh, Toshiya; Tomita, Kouhei
When a store sells items to customers, the store wishes to decide the prices of items to maximize its profit. Intuitively, if the store sells the items with low (resp. high) prices, the customers buy more (resp. less) items, which provides less profit to the store. So it would be hard for the store to decide the prices of items. Assume that the store has a set V of n items and there is a set E of m customers who wish to buy the items, and also assume that each item i ∈ V has the production cost di and each customer ej ∈ E has the valuation vj on the bundle ej ⊆ V of items. When the store sells an item i ∈ V at the price ri, the profit for the item i is pi = ri - di. The goal of the store is to decide the price of each item to maximize its total profit. We refer to this maximization problem as the item pricing problem. In most of the previous works, the item pricing problem was considered under the assumption that pi ≥ 0 for each i ∈ V, however, Balcan, et al. [In Proc. of WINE, LNCS 4858, 2007] introduced the notion of “loss-leader, ” and showed that the seller can get more total profit in the case that pi < 0 is allowed than in the case that pi < 0 is not allowed. In this paper, we consider the line highway problem (in which each customer is interested in an interval on the line of the items) and the cycle highway problem (in which each customer is interested in an interval on the cycle of the items), and show approximation algorithms for the line highway problem and the cycle highway problem in which the smallest valuation is s and the largest valuation is l (this is called an [s, l]-valuation setting) or all valuations are identical (this is called a single valuation setting).
Tetanus toxoid-pulsed monocyte vaccination for augmentation of collateral vessel growth.
Herold, Joerg; Francke, Alexander; Weinert, Soenke; Schmeisser, Alexander; Hebel, Katrin; Schraven, Burkhart; Roehl, Friedich-Wilhelm; Strasser, Ruth H; Braun-Dullaeus, Ruediger C
2014-04-14
The pathogenesis of collateral growth (arteriogenesis) has been linked to both the innate and adaptive immune systems. While therapeutic approaches for the augmentation of arteriogenesis have focused on innate immunity, exploiting both innate and adaptive immune responses has not been examined. We hypothesized that tetanus toxoid (tt) immunization of mice followed by transplantation of monocytes (Mo) exposed ex vivo to tt augments arteriogenesis after ligation of the hind limb. Mo were generated from nonimmunized BALB/c mice, exposed ex vivo to tt for 24 hours and intravenously injected (ttMo, 2.5×10(6)) into the tail veins of tt-immunized syngeneic mice whose hind limbs had been ligated 24 hours prior to transplantation. Laser Doppler perfusion imaging was applied, and a perfusion index (PI) was calculated (ratio ligated/unligated). Twenty-one days after ligation, the arteriogenesis of untreated BALB/c mice was limited (PI=0.49±0.09). Hind limb function was impaired in 80% of animals. Injection of non-engineered Mo insignificantly increased the PI to 0.56±0.07. However, ttMo transplantation resulted in a strong increase of the PI to 0.82±0.08 (n=7; P<0.001), with no (0%) detectable functional impairment. ttMo injected into nonimmunized mice had no effect. The strong arteriogenic response of ttMo transplantation into immunized mice was prevented when mice had been depleted of T-helper cells by CD4-antibody pretreatment (PI=0.50±0.08; n=17; P<0.001), supporting the hypothesis that transplanted cells interact with recipient lymphocytes. Transplantation of ttMo into pre-immunized mice strongly promotes arteriogenesis. This therapeutic approach is feasible and highly attractive for the alleviation of morbidity associated with vascular occlusive disease.
Tetanus Toxoid‐Pulsed Monocyte Vaccination for Augmentation of Collateral Vessel Growth
Herold, Joerg; Francke, Alexander; Weinert, Soenke; Schmeisser, Alexander; Hebel, Katrin; Schraven, Burkhart; Roehl, Friedich‐Wilhelm; Strasser, Ruth H.; Braun‐Dullaeus, Ruediger C.
2014-01-01
Background The pathogenesis of collateral growth (arteriogenesis) has been linked to both the innate and adaptive immune systems. While therapeutic approaches for the augmentation of arteriogenesis have focused on innate immunity, exploiting both innate and adaptive immune responses has not been examined. We hypothesized that tetanus toxoid (tt) immunization of mice followed by transplantation of monocytes (Mo) exposed ex vivo to tt augments arteriogenesis after ligation of the hind limb. Methods and Results Mo were generated from nonimmunized BALB/c mice, exposed ex vivo to tt for 24 hours and intravenously injected (ttMo, 2.5×106) into the tail veins of tt‐immunized syngeneic mice whose hind limbs had been ligated 24 hours prior to transplantation. Laser Doppler perfusion imaging was applied, and a perfusion index (PI) was calculated (ratio ligated/unligated). Twenty‐one days after ligation, the arteriogenesis of untreated BALB/c mice was limited (PI=0.49±0.09). Hind limb function was impaired in 80% of animals. Injection of non‐engineered Mo insignificantly increased the PI to 0.56±0.07. However, ttMo transplantation resulted in a strong increase of the PI to 0.82±0.08 (n=7; P<0.001), with no (0%) detectable functional impairment. ttMo injected into nonimmunized mice had no effect. The strong arteriogenic response of ttMo transplantation into immunized mice was prevented when mice had been depleted of T‐helper cells by CD4‐antibody pretreatment (PI=0.50±0.08; n=17; P<0.001), supporting the hypothesis that transplanted cells interact with recipient lymphocytes. Conclusions Transplantation of ttMo into pre‐immunized mice strongly promotes arteriogenesis. This therapeutic approach is feasible and highly attractive for the alleviation of morbidity associated with vascular occlusive disease. PMID:24732919
NASA Astrophysics Data System (ADS)
Bakhodurov, A. U.; Vashourin, N. S.; Vinogradov, E. A.; Gazizov, K. Sh.; Kompanets, V. O.; Popov, I. I.; Putilin, S. E.; Chekalin, S. V.
2017-10-01
This paper reflects the results of the research on the character of the dependence of the non-Faraday rotation of the femtosecond stimulated photon echo polarization plane on the time interval between the second and third exciting pulses, discretely varying from 180 to 900 fs in increments 180 fs. The time interval between the first and second pulses was equal to zero. The echo signal was formed at room temperature on exciton states localized on the surface defects of a thin three-layer textured ZnO/Si(P)/Si(B) film in the presence of a homogeneous magnetic field of 0.25 mT applied longitudinally to the optical excitation axis. The qualitative coincidence of the investigated dependence with the theoretical prediction of the investigated effect for gaseous medium is shown.
Pulsed Thrust Method for Hover Formation Flying
NASA Technical Reports Server (NTRS)
Hope, Alan; Trask, Aaron
2003-01-01
A non-continuous thrust method for hover type formation flying has been developed. This method differs from a true hover which requires constant range and bearing from a reference vehicle. The new method uses a pulsed loop, or pogo, maneuver sequence that keeps the follower spacecraft within a defined box in a near hover situation. Equations are developed for the hover maintenance maneuvers. The constraints on the hover location, pulse interval, and maximum/minimum ranges are discussed.
Miura, Naoto; Watanabe, Takashi
2016-01-01
Clinical studies on application of functional electrical stimulation (FES) to motor rehabilitation have been increasing. However, muscle fatigue appears early in the course of repetitive movement production training by FES. Although M-wave variables were suggested to be reliable indices of muscle fatigue in long lasting constant electrical stimulation under the isometric condition, the ability of M-wave needs more studies under intermittent stimulation condition, because the intervals between electrical stimulations help recovery of muscle activation level. In this paper, M-waves elicited by double pulses were examined in muscle fatigue evaluation during repetitive movements considering rehabilitation training with surface electrical stimulation. M-waves were measured under the two conditions of repetitive stimulation: knee extension force production under the isometric condition and the dynamic movement condition by knee joint angle control. Amplitude of M-wave elicited by the 2nd pulse of a double pulse decreased during muscle fatigue in both measurement conditions, while the change in M-waves elicited by single pulses in a stimulation burst was not relevant to muscle fatigue in repeated activation with stimulation interval of 1 s. Fatigue index obtained from M-waves elicited by 2nd pulses was suggested to provide good estimation of muscle fatigue during repetitive movements with FES. PMID:27110556
Particle field diagnose using angular multiplexing volume holography
NASA Astrophysics Data System (ADS)
Zhao, Yu; Li, Zeren; Luo, Zhenxiong; Jun, Li; Zhong, Jie; Ye, Yan; Li, Shengfu; Zhu, Jianhua
2017-08-01
The problem of particle field diagnosing using holography can be met in many areas. But single frame hologram can only catch one moment of the fast event, which can't reveal the change process of an unrepeatable fast event. For events in different time-scale, different solution should be used. We did this work to record a laser induced particle field in the time-scale of tens of micron seconds. A laser of pulse sequence mode is applied to provide 10 pulses, the energy and time interval of whom is 150mJ and 1μs. Four pockels cells are employed to pick up the last four pulses for holographic recording, the other pulses are controlled to pre-expose the photopolymer based recording material, which can enhance photosensitivity of the photopolymer during the moment of holographic recording. The angular multiplexing technique and volume holography is accepted to avoid shifting the photopolymer between each shot. Another Q-switch YAG laser (pulse energy 100mJ, pulse width 10ns) is applied to produce the fast event. As a result, we successfully caught the motion process of the laser induced particle field. The time interval of each frame is 1μs, the angular range of the four references is 14°, and the diffraction efficiency of each hologram is less than 2%. After a basic analysis, this optical system could catch more holograms through a compact design.
Diotte, M; Miguelez, M; Miliaressis, E; Bielajew, C
2000-12-05
The interaction between rewarding and aversive consequences of brain stimulation were assessed in two studies. In the first, the frequency threshold for 300 ms trains of combined lateral hypothalamic (LH) and nucleus reticularis gigantocellularis (Gi) stimulation, in which each LH pulse was followed 2 ms later by the Gi one, was determined for one month. Compared to the threshold for trains of single LH pulses, combined LH-Gi stimulation initially increased the frequency threshold; however, this effect reversed within one session and was subsequently maintained for the duration of the study. The aversion produced by Gi stimulation, as measured by latency to escape, was abolished following a single session of LH-Gi pairs. In the second study, a subset of animals received both presentations of combined pulses, LH followed by Gi, and the reverse; the interval between pulses was varied from 0.2 to 6.4 ms. The effectiveness of combined stimulation, determined by the ratio of LH frequency thresholds to that of the LH-Gi ranged from 0 to 50% across animals but the individual effectiveness functions within animals did not vary with different intervals. In addition, the order of presentation of pulses was of no consequence. Thus, not only did exposure to LH stimulation appear to obliterate Gi aversion, but the combination of LH and Gi pulses added to the rewarding effect produced by LH stimulation alone.
Generating nonlinear FM chirp radar signals by multiple integrations
Doerry, Armin W [Albuquerque, NM
2011-02-01
A phase component of a nonlinear frequency modulated (NLFM) chirp radar pulse can be produced by performing digital integration operations over a time interval defined by the pulse width. Each digital integration operation includes applying to a respectively corresponding input parameter value a respectively corresponding number of instances of digital integration.
Realization of transient memory-loss with NiO-based resistive switching device
NASA Astrophysics Data System (ADS)
Hu, S. G.; Liu, Y.; Chen, T. P.; Liu, Z.; Yu, Q.; Deng, L. J.; Yin, Y.; Hosaka, Sumio
2012-11-01
A resistive switching device based on a nickel-rich nickel oxide thin film, which exhibits inherent learning and memory-loss abilities, is reported in this work. The conductance of the device gradually increases and finally saturates with the number of voltage pulses (or voltage sweepings), which is analogous to the behavior of the short-term and long-term memory in the human brain. Furthermore, the number of the voltage pulses (or sweeping cycles) required to achieve a given conductance state increases with the interval between two consecutive voltage pulses (or sweeping cycles), which is attributed to the heat diffusion in the material of the conductive filaments formed in the nickel oxide thin film. The phenomenon resembles the behavior of the human brain, i.e., forgetting starts immediately after an impression, a larger interval of the impressions leads to more memory loss, thus the memorization needs more impressions to enhance.
5.8kV SiC PiN Diode for Switching of High-Efficiency Inductive Pulsed Plasma Thruster Circuits
NASA Technical Reports Server (NTRS)
Toftul, Alexandra; Polzin, Kurt A.; Hudgins, Jerry L.
2014-01-01
Inductive Pulsed Plasma Thruster (IPPT) pulse circuits, such as those needed to operate the Pulsed Inductive Thruster (PIT), are required to quickly switch capacitor banks operating at a period of µs while conducting current at levels on the order of at least 10 kA. [1,2] For all iterations of the PIT to date, spark gaps have been used to discharge the capacitor bank through an inductive coil. Recent availability of fast, high-power solid state switching devices makes it possible to consider the use of semiconductor switches in modern IPPTs. In addition, novel pre-ionization schemes have led to a reduction in discharge energy per pulse for electric thrusters of this type, relaxing the switching requirements for these thrusters. [3,4] Solid state switches offer the advantage of greater controllability and reliability, as well as decreased drive circuit dimensions and mass relative to spark gap switches. The use of solid state devices such as Integrated Gate Bipolar Transistors (IGBTs), Gate Turn-off Thyristors (GTOs) and Silicon-Controlled Rectifiers (SCRs) often involves the use of power diodes. These semiconductor devices may be connected antiparallel to the switch for protection from reverse current, or used to reduce power loss in a circuit by clamping off current ringing. In each case, higher circuit efficiency may be achieved by using a diode that is able to transition, or 'switch,' from the forward conducting state ('on' state) to the reverse blocking state ('off' state) in the shortest amount of time, thereby minimizing current ringing and switching losses. Silicon Carbide (SiC) PiN diodes offer significant advantages to conventional fast-switching Silicon (Si) diodes for high power and fast switching applications. A wider band gap results in a breakdown voltage 10 times that of Si, so that a SiC device may have a thinner drift region for a given blocking voltage. [5] This leads to smaller, lighter devices for high voltage applications, as well as reduced forward conduction losses, faster reverse recovery time (faster turn-off), and lower-magnitude reverse recovery current. In addition, SiC devices have lower leakage current as compared to their Si counterparts, and a high thermal conductivity, potentially allowing the former to operate at higher temperatures with a smaller, lighter heatsink (or no heatsink at all).
Dual fuel injection piggyback controller system
NASA Astrophysics Data System (ADS)
Muji, Siti Zarina Mohd.; Hassanal, Muhammad Amirul Hafeez; Lee, Chua King; Fawzi, Mas; Zulkifli, Fathul Hakim
2017-09-01
Dual-fuel injection is an effort to reduce the dependency on diesel and gasoline fuel. Generally, there are two approaches to implement the dual-fuel injection in car system. The first approach is changing the whole injector of the car engine, the consequence is excessive high cost. Alternatively, it also can be achieved by manipulating the system's control signal especially the Electronic Control Unit (ECU) signal. Hence, the study focuses to develop a dual injection timing controller system that likely adopted to control injection time and quantity of compressed natural gas (CNG) and diesel fuel. In this system, Raspberry Pi 3 reacts as main controller unit to receive ECU signal, analyze it and then manipulate its duty cycle to be fed into the Electronic Driver Unit (EDU). The manipulation has changed the duty cycle to two pulses instead of single pulse. A particular pulse mainly used to control injection of diesel fuel and another pulse controls injection of Compressed Natural Gas (CNG). The test indicated promising results that the system can be implemented in the car as piggyback system. This article, which was originally published online on 14 September 2017, contained an error in the acknowledgment section. The corrected acknowledgment appears in the Corrigendum attached to the pdf.
All-Optical Ultrasound Transducers for High Resolution Imaging
NASA Astrophysics Data System (ADS)
Sheaff, Clay Smith
High frequency ultrasound (HFUS) has increasingly been used within the past few decades to provide high resolution (< 200 mum) imaging in medical applications such as endoluminal imaging, intravascular imaging, ophthalmology, and dermatology. The optical detection and generation of HFUS using thin films offers numerous advantages over traditional piezoelectric technology. Circumvention of an electronic interface with the device head is one of the most significant given the RF noise, crosstalk, and reduced capacitance that encumbers small-scale electronic transducers. Thin film Fabry-Perot interferometers - also known as etalons - are well suited for HFUS receivers on account of their high sensitivity, wide bandwidth, and ease of fabrication. In addition, thin films can be used to generate HFUS when irradiated with optical pulses - a method referred to as Thermoelastic Ultrasound Generation (TUG). By integrating a polyimide (PI) film for TUG into an etalon receiver, we have created for the first time an all-optical ultrasound transducer that is both thermally stable and capable of forming fully sampled 2-D imaging arrays of arbitrary configuration. Here we report (1) the design and fabrication of PI-etalon transducers; (2) an evaluation of their optical and acoustic performance parameters; (3) the ability to conduct high-resolution imaging with synthetic 2-D arrays of PI-etalon elements; and (4) work towards a fiber optic PI-etalon for in vivo use. Successful development of a fiber optic imager would provide a unique field-of-view thereby exposing an abundance of prospects for minimally-invasive analysis, diagnosis, and treatment of disease.
Sampling and Control Circuit Board for an Inertial Measurement Unit
NASA Technical Reports Server (NTRS)
Chelmins, David T (Inventor); Sands, Obed (Inventor); Powis, Richard T., Jr. (Inventor)
2016-01-01
A circuit board that serves as a control and sampling interface to an inertial measurement unit ("IMU") is provided. The circuit board is also configured to interface with a local oscillator and an external trigger pulse. The circuit board is further configured to receive the external trigger pulse from an external source that time aligns the local oscillator and initiates sampling of the inertial measurement device for data at precise time intervals based on pulses from the local oscillator. The sampled data may be synchronized by the circuit board with other sensors of a navigation system via the trigger pulse.
Anticipation of periodic environmental changes in an amoeba
NASA Astrophysics Data System (ADS)
Saigusa, Tetsu; Nakagaki, Toshiyuki
2007-07-01
The amoeboid organism of true slime mold, the plasmodium of Physarum polycephalum, had capacity of memorizing a periodic event. The organism showed vigorous locomotion in the favorite conditions. When stimulation of the unfavorable conditions was given in a pulse-like regime and was repeated three times at interval of 60 minutes, the amoeba reduced the locomotion speed in response to each pulse. Even though the favorite conditions were kept to be constant after the periodic pulses, the amoeba spontaneously reduced the locomotion speed at the timing of next pulse (after 60 minutes). This means that the amoeba anticipated the next environmental change.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1984-12-31
(I)Results are given for photoproduction of the D{sup *} at 103 GeV. Clean signals are seen for the decay D{sup *{+-}} {yields} {pi}{sup {+-}}D{sup 0} with the D{sup 0} decaying into both K{sup {-+}}{pi}{sup {+-}} and K{sup {-+}}{pi}{sup {+-}}{pi}{sup 0}. Analysis of the Dalitz plot for the K{pi}{pi} mode gives branching fractions (BFs) for K{sup {minus}}{rho}{sup +}, K{sup *{minus}}{pi}{sup +}, and {anti K}{sup *0}{pi}{sup 0} final states. The BF for D{sup 0} {yields} K{sup {minus}}{rho}{sup +}, much lower than a previous result, is in approximate agreement with the value expected for an l=1/2 final state. (II)Inelastic and elastic J/{psi} photoproductionmore » on H is investigated at 103 GeV. The inelastic cross section with E{sub {psi}}/E{sub {gamma}} {lt} 0.9 is significantly lower than the corresponding result for muoproduction on Fe targets, but consistent with second-order perturbative QCD calculation. The mean p{sub +} of inelastic events is larger than that of elastic events. (III)Analysis of data from the CLEO experiment has yielded evidence for B{bar B} production from the 4S upsilon state. A preliminary cross section is shown. (IV)The SSD prototyping and testing program is described. The detectors performed as expected. (V)Three 24 x 36 mm{sup 2} Centronic detectors 300 microns thick were tested in 650-MeV/c proton and 600-MeV/c pion beams. Charge sharing was found to occur. (VI)Tests of attenuation lengths and light output were made on three types of scintillator: NE102A, PS12, and PS10. PS10 appears the most suitable. (VII)Charge-sharing SSDs of (V) were subject to analysis: checking of pulse heights of single stripes, hit pairs, and hit quads vs theoretical values; resolution of three-point proton/pion tracks, and characterization of devices by charge sum/difference plots of hit pairs. (VIII) Board fabrication and tests of a hadron calorimeter intended to be 91 x 91 sq.in. are discussed. (IX)Testing of an amplifier with LRS hybrid preamp is related.« less
Active lamp pulse driver circuit. [optical pumping of laser media
NASA Technical Reports Server (NTRS)
Logan, K. E. (Inventor)
1983-01-01
A flashlamp drive circuit is described which uses an unsaturated transistor as a current mode switch to periodically subject a partially ionized gaseous laser excitation flashlamp to a stable, rectangular pulse of current from an incomplete discharge of an energy storage capacitor. A monostable multivibrator sets the pulse interval, initiating the pulse in response to a flash command by providing a reference voltage to a non-inverting terminal of a base drive amplifier; a tap on an emitter resistor provides a feedback signal sensitive to the current amplitude to an inverting terminal of amplifier, thereby controlling the pulse amplitude. The circuit drives the flashlamp to provide a squarewave current flashlamp discharge.
Ambient Ozone Pollution and Daily Mortality: A Nationwide Study in 272 Chinese Cities.
Yin, Peng; Chen, Renjie; Wang, Lijun; Meng, Xia; Liu, Cong; Niu, Yue; Lin, Zhijing; Liu, Yunning; Liu, Jiangmei; Qi, Jinlei; You, Jinling; Zhou, Maigeng; Kan, Haidong
2017-11-21
Few large multicity studies have been conducted in developing countries to address the acute health effects of atmospheric ozone pollution. We explored the associations between ozone and daily cause-specific mortality in China. We performed a nationwide time-series analysis in 272 representative Chinese cities between 2013 and 2015. We used distributed lag models and over-dispersed generalized linear models to estimate the cumulative effects of ozone (lagged over 0-3 d) on mortality in each city, and we used hierarchical Bayesian models to combine the city-specific estimates. Regional, seasonal, and demographic heterogeneity were evaluated by meta-regression. At the national-average level, a 10-μg/m 3 increase in 8-h maximum ozone concentration was associated with 0.24% [95% posterior interval (PI): 0.13%, 0.35%], 0.27% (95% PI: 0.10%, 0.44%), 0.60% (95% PI: 0.08%, 1.11%), 0.24% (95% PI: 0.02%, 0.46%), and 0.29% (95% PI: 0.07%, 0.50%) higher daily mortality from all nonaccidental causes, cardiovascular diseases, hypertension, coronary diseases, and stroke, respectively. Associations between ozone and daily mortality due to respiratory and chronic obstructive pulmonary disease specifically were positive but imprecise and nonsignificant. There were no statistically significant differences in associations between ozone and nonaccidental mortality according to region, season, age, sex, or educational attainment. Our findings provide robust evidence of higher nonaccidental and cardiovascular mortality in association with short-term exposure to ambient ozone in China. https://doi.org/10.1289/EHP1849.
Yan, Xiaona; Gao, Lirun; Yang, Xihua; Dai, Ye; Chen, Yuanyuan; Ma, Guohong
2014-10-20
A scheme to generate individually modulated femtosecond pulse string by multilayer volume holographic grating (MVHG) is proposed. Based on Kogelnik's coupled-wave theory and matrix optics, temporal and spectral expressions of diffracted field are given when a femtosecond pulse is diffracted by a MVHG. It is shown that the number of diffracted sub-pulses in the pulse string equals to the number of grating layers of the MVHG, peak intensity and duration of each diffracted sub-pulse depend on thickness of the corresponding grating layer, whereas pulse interval between adjacent sub-pulses is related to thickness of the corresponding buffer layer. Thus by modulating parameters of the MVHG, individually modulated femtosecond pulse string can be acquired. Based on Bragg selectivity of the volume grating and phase shift provided by the buffer layers, we give an explanation on these phenomena. The result is useful to design MVHG-based devices employed in optical communications, pulse shaping and processing.
Comparison between Trichel pulse in negative corona and self-pulsing in other configurations
NASA Astrophysics Data System (ADS)
Xia, Qing; Zhang, Yu; He, Feng; Qin, Yu; Jiang, Zhaorui; Ouyang, Jiting
2018-02-01
We present here a comparison study on self-pulsing phenomena in negative corona, hollow cathode discharges (HCD) and parallel-plate discharge in air. The voltage-current (V-I) curve, the waveforms of self-pulsed currents, and the time-resolved images of the pulsed discharge are measured under various operating conditions. It is experimentally evidenced that the Trichel pulse in a negative corona and the self-pulsing in HCD and/or parallel-plate discharge have similar features as well as spatial-temporal developing process. It is suggested that they should have a similar mechanism that the pulsing reflects the mode transition of discharge between the low-current Townsend and the high-current normal glow. The pulse rising corresponds to the breakdown and formation of temporal glow discharge in a background of low-current Townsend discharge, while the decay edge relates to the transition back to Townsend discharge. The pulse interval is the re-building process of the space charge layer of high density to ensure the glow breakdown.
SAMIR, Haney; SASAKI, Kazuaki; AHMED, Eman; KAREN, Aly; NAGAOKA, Kentaro; EL SAYED, Mohamed; TAYA, Kazuyoshi; WATANABE, Gen
2015-01-01
Although color Doppler ultrasonography has been used to evaluate testicular blood flow in many species, very little has been done in goat. Eight male Shiba goats were exposed to a single intramuscular injection of either gonadotropin-releasing hormone (GnRH group; 1 µg/kg BW) or human chorionic gonadotropin (hCG group; 25 IU/kg BW). Plasma testosterone (T), estradiol (E2) and inhibin (INH) were measured just before (0 hr) and at different intervals post injection by radioimmunoassay. Testis volume (TV) and Doppler indices, such as resistive index (RI) and pulsatility index (PI) of the supratesticular artery, were measured by B-mode and color Doppler ultrasonography, respectively. The results indicated an increase in testicular blood flow in both groups, as RI and PI decreased significantly (P<0.05), but this increase was significant higher and earlier in hCG group (1 hr) than in the GnRH group (2 hr). A high correlation was found for RI and PI with both T (RI, r= −0.862; PI, r= −0.707) and INH in the GnRH group (RI, r=0.661; PI, r=0.701). However, a significant (P<0.05) correlation was found between E2 and both RI (r= −0.610) and PI (r= −0.763) in hCG group. In addition, TV significantly increased and was highly correlated with RI in both groups (GnRH, r= −0.718; hCG, r= −0.779). In conclusion, hCG and GnRH may improve testicular blood flow and TV in Shiba goats. PMID:25715956
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, J.H.; Park, C.R.; Brown, R.L.
Functional compartments of fast and slow twitch fibers have been observed by /sup 31/P-NMR spectroscopy during exercise of the wrist flexor muscles in a sedentary, young male subject. Values of Pi, phosphocreatine (PCr) and adenine nucleotides were determined at rest and during an exercise protocol. The subject flexed his wrist muscles at 20% of maximum strength every 5 sec for 6 min and then increased his effort in the next two 6 min intervals to 40% and 60% of maximum. With exercise, the Pi/PCr rose rapidly to the exceptionally high value of 2.2 at 60% effort. As the Pi increased,more » the initial single peak (pH 7.0-6.9) split into two distinct components with pH values of 6.8 and 6.3. Quantitatively, distribution of the Pi was 40% in the pH 6.8 peak and 60% in the pH 6.3 peak as determined by area estimation following curve fitting. This presumably reflects two pools of Pi corresponding to the oxidative (slow twitch, high pH) and glycolytic (fast twitch, low pH) fibers. In the second identical exercise sequence which followed immediately, only one Pi peak (pH 6.8-6.9) appeared. This suggested that the glycolytic contribution to energy production was largely exhausted and the residual energy was derived from oxidative metabolism. During exercise at high levels, total phosphate decreased due primarily to loss of NMR visible adenine nucleotides. Similar phenomena have been observed in three other sedentary individuals, but not in trained athletes.« less
Alpha-1 antitrypsin Pi*Z gene frequency and Pi*ZZ genotype numbers worldwide: an update.
Blanco, Ignacio; Bueno, Patricia; Diego, Isidro; Pérez-Holanda, Sergio; Casas-Maldonado, Francisco; Esquinas, Cristina; Miravitlles, Marc
2017-01-01
In alpha-1 antitrypsin deficiency (AATD), the Z allele is present in 98% of cases with severe disease, and knowledge of the frequency of this allele is essential from a public health perspective. However, there is a remarkable lack of epidemiological data on AATD worldwide, and many of the data currently used are outdated. Therefore, the objective of this study was to update the knowledge of the frequency of the Z allele to achieve accurate estimates of the prevalence and number of Pi*ZZ genotypes worldwide based on studies performed according to the following criteria: 1) samples representative of the general population, 2) AAT phenotyping characterized by adequate methods, and 3) measurements performed using a coefficient of variation calculated from the sample size and 95% confidence intervals. Studies fulfilling these criteria were used to develop maps with an inverse distance weighted (IDW)-interpolation method, providing numerical and graphical information of Pi*Z distribution worldwide. A total of 224 cohorts from 65 countries were included in the study. With the data provided by these cohorts, a total of 253,404 Pi*ZZ were estimated worldwide: 119,594 in Europe, 91,490 in America and Caribbean, 3,824 in Africa, 32,154 in Asia, 4,126 in Australia, and 2,216 in New Zealand. In addition, the IDW-interpolation maps predicted Pi*Z frequencies throughout the world even in some areas that lack real data. In conclusion, the inclusion of new well-designed studies and the exclusion of the low-quality ones have significantly improved the reliability of results, which may be useful to plan strategies for future research and diagnosis and to rationalize the therapeutic resources available.
Serraes, Brecht; Beeckman, Dimitri
2016-01-01
The aim of this study was to investigate the incidence and risk factors for developing pressure injuries (PIs) in patients placed on a static air support surfaces: mattress overlay, heel wedge, and seat cushion. Multicenter cohort study. The sample comprised 176 residents; their mean age was 87 (SD = 6.76) years; their mean Braden Scale score was 14 (SD = 2.54). The study was performed on a convenience sample of 6 nursing homes in Belgium. Data were collected on 23 care units. The primary outcome measure, cumulative PI incidence (category [stage] II-IV) over a 30-day observation period, was calculated. Pressure injury occurrence was defined according to the 2014 European and US National Pressure Injury Advisory panels, Pan Pacific Pressure Injury Alliance classification system. The PI incidence for category (stage) II-IV was 5.1%. Six residents (3.4%) developed a category II PI, and 3 (1.7%) developed a category III PI; no category IV ulcers occurred. No significant risk factors for category II-IV PIs were identified using multivariate logistic regression. Time of sitting in a chair was found to be a risk factor for development of nonblanchable erythema (category I PI) (odds ratio = 21.608; 95% confidence interval [CI], 20.510-22.812; P = .013). The median time to develop a category II-IV PI was 16 days (interquartile range = 2-26). The interrater reliability between the observations of the researcher and nurses on-site was almost perfect (0.86; 95% CI, 0.81-0.91). We found a low incidence of PIs when using a static air overlay mattress for patients at risk in a nursing home population. Static air support surfaces, alongside patient-tailored patient repositioning protocols, should be considered to prevent PIs in this patient population.
NASA Technical Reports Server (NTRS)
Intriligator, Devrie S.; Detman, Thomas; Gloecker, George; Gloeckler, Christine; Dryer, Murray; Sun, Wei; Intriligator, James; Deehr, Charles
2012-01-01
We report the first comparisons of pickup proton simulation results with in situ measurements of pickup protons obtained by the SWICS instrument on Ulysses. Simulations were run using the three dimensional (3D) time-dependent Hybrid Heliospheric Modeling System with Pickup Protons (HHMS-PI). HHMS-PI is an MHD solar wind model, expanded to include the basic physics of pickup protons from neutral hydrogen that drifts into the heliosphere from the local interstellar medium. We use the same model and input data developed by Detman et al. (2011) to now investigate the pickup protons. The simulated interval of 82 days in 2003 2004, includes both quiet solar wind (SW) and also the October November 2003 solar events (the Halloween 2003 solar storms). The HHMS-PI pickup proton simulations generally agree with the SWICS measurements and the HHMS-PI simulated solar wind generally agrees with SWOOPS (also on Ulysses) measurements. Many specific features in the observations are well represented by the model. We simulated twenty specific solar events associated with the Halloween 2003 storm. We give the specific values of the solar input parameters for the HHMS-PI simulations that provide the best combined agreement in the times of arrival of the solar-generated shocks at both ACE and Ulysses. We show graphical comparisons of simulated and observed parameters, and we give quantitative measures of the agreement of simulated with observed parameters. We suggest that some of the variations in the pickup proton density during the Halloween 2003 solar events may be attributed to depletion of the inflowing local interstellar medium (LISM) neutral hydrogen (H) caused by its increased conversion to pickup protons in the immediately preceding shock.
RXTE and BeppoSAX Observations of the Transient X-ray Pulsar XTE J 18591+083
NASA Technical Reports Server (NTRS)
Corbet, R. H. D.; intZand, J. J. M.; Levine, A. M.; Marshall, F. E.
2008-01-01
We present observations of the 9.8 s X-ray pulsar XTE J159+083 made with the All-Sky Monitor (ASM) and Proportional Counter Array (PCA) on board the Rossi X-ray Timing Explorer (RXTE), and the Wide Field Cameras (WFC) on board BeppoSAX. The ASM data cover a 12 year time interval and show that an extended outburst occurred between approximately MJD50, 250, and 50, 460 (1996 June 16 to 1997 January 12). The ASM data excluding this outburst interval suggest a possible 61 day modulation. Eighteen sets of PCA observations were obtained over an approx. one month interval in 1999. The flux variability measured with the PCA appears consistent with the possible period found with the ASM. The PCA measurements of the pulse period showed it to decrease non-monotonically and then to increase significantly. Doppler shifts due to orbital motion rather than accretion torques appear to be better able to explain the pulse period changes. Observations with the WFC during the extended outburst give an error box which is consistent with a previously determined PCA error box but is significantly smaller. The transient nature of XTE J1859+083 and the length of its pulse period are consistent with it being a Be/neutral star binary. The possible 61 day orbital period would be of the expected length for a Be star system with a 9.8 s pulse period.
Bayesian analyses of time-interval data for environmental radiation monitoring.
Luo, Peng; Sharp, Julia L; DeVol, Timothy A
2013-01-01
Time-interval (time difference between two consecutive pulses) analysis based on the principles of Bayesian inference was investigated for online radiation monitoring. Using experimental and simulated data, Bayesian analysis of time-interval data [Bayesian (ti)] was compared with Bayesian and a conventional frequentist analysis of counts in a fixed count time [Bayesian (cnt) and single interval test (SIT), respectively]. The performances of the three methods were compared in terms of average run length (ARL) and detection probability for several simulated detection scenarios. Experimental data were acquired with a DGF-4C system in list mode. Simulated data were obtained using Monte Carlo techniques to obtain a random sampling of the Poisson distribution. All statistical algorithms were developed using the R Project for statistical computing. Bayesian analysis of time-interval information provided a similar detection probability as Bayesian analysis of count information, but the authors were able to make a decision with fewer pulses at relatively higher radiation levels. In addition, for the cases with very short presence of the source (< count time), time-interval information is more sensitive to detect a change than count information since the source data is averaged by the background data over the entire count time. The relationships of the source time, change points, and modifications to the Bayesian approach for increasing detection probability are presented.
Boulton, A P; Pascall, J C; Craig, R K
1984-01-01
Golgi and endoplasmic-reticulum fractions were prepared from the lactating guinea-pig mammary gland. The endoplasmic-reticulum fraction was highly active in the processing and sequestration of milk-protein primary translation products. Explants from the lactating gland in organ culture were used to identify milk-protein intermediates present in the secretory pathway, and the timing of the events leading to their post-translational modification. With [35S]methionine, the milk proteins labelled after a short pulse (3 min) were represented by the partially processed (but not phosphorylated) caseins and alpha-lactalbumin sequestered within membrane-bound vesicles. After a 30 min labelling period, higher-Mr caseins with electrophoretic mobilities identical with those of the phosphorylated caseins isolated from milk were identified in the incubation medium, and sequestered within membrane-bound vesicles. Pulse-chase experiments established a precursor-product relationship between these forms. Secretion is apparent approx. 30 min after sequestration. Caseins are highly phosphorylated; removal of the phosphate residues with acid phosphatase results in proteins with increased electrophoretic mobility, similar to those of the partially processed early casein intermediates found sequestered in explants after a 3 min pulse with [35S]methionine, and those sequestered within microsomal membranes after mRNA-directed cell-free protein synthesis. A comparison of the proteins labelled during both short (5 min) and long (30 min) pulses with [35S]methionine and [32P]Pi shows that, in contrast with the 35S-labelled caseins, those labelled with [32P]Pi exhibit only electrophoretic mobilities identical with those of the mature caseins isolated from milk and those identified after long labelling periods with [35S]methionine. No phosphorylated early intermediate forms of caseins were identified. We conclude that the synthesis and post-translational modification of guinea-pig caseins occurs in two stages, (i) an early event involving synthesis and sequestration within the endoplasmic reticulum, an event that involves signal-peptide removal, followed (ii) 10-20 min later by phosphorylation at a different point in the secretory pathway, probably in the Golgi complex. Secretion of the phosphorylated caseins occurs 10-20 min later. Images Fig. 1. Fig. 2. Fig. 3. Fig. 4. Fig. 5. PMID:6477529
A ruggedness evaluation of procedures for damage threshold testing optical materials
NASA Technical Reports Server (NTRS)
Hooker, Matthew W.; Thomas, Milfred E.; Wise, Stephanie A.; Tappan, Nina D.
1995-01-01
A ruggedness evaluation of approaches to damage threshold testing was performed to determine the influence of three procedural variables on damage threshold data. The differences between the number of test sites evaluated at an applied fluence level (1 site versus 10 sites), the number of laser pulses at each test site (1 pulse versus 200 pulses), and the beam diameter (0.35 mm versus 0.70 mm) were all found to significantly influence the damage threshold data over a 99-percent confidence interval.
NASA Technical Reports Server (NTRS)
Woods, J. M. (Inventor)
1973-01-01
An electrical power distribution system is described for use in providing different dc voltage levels. A circuit is supplied with DC voltage levels and commutates pulses for timed intervals onto a pair of distribution wires. The circuit is driven by a command generator which places pulses on the wires in a timed sequence. The pair of wires extend to voltage strippers connected to the various loads. The voltage strippers each respond to the pulse dc levels on the pair of wires and form different output voltages communicated to each load.
Interstellar scattering of the Vela pulsar
NASA Technical Reports Server (NTRS)
Backer, D. C.
1974-01-01
The frequency dependence of the parameters of interstellar scattering between 837 and 8085 MHz for the Vela pulsar are consistent with thin-screen models of strong scattering. The magnitudes of the parameters indicate an anomalous turbulence along the path when they are compared with results for other pulsars with comparable column densities of free electrons in the line of sight. This anomaly is due presumably to the Gum Nebula. The decorrelation frequency, appropriately defined, is related to the pulse broadening time by 2 pi as predicted theoretically.
Hadamard-Encoded Multipulses for Contrast-Enhanced Ultrasound Imaging.
Gong, Ping; Song, Pengfei; Chen, Shigao
2017-11-01
The development of contrast-enhanced ultrasound (CEUS) imaging offers great opportunities for new ultrasound clinical applications such as myocardial perfusion imaging and abdominal lesion characterization. In CEUS imaging, the contrast agents (i.e., microbubbles) are utilized to improve the contrast between blood and tissue based on their high nonlinearity under low ultrasound pressure. In this paper, we propose a new CEUS pulse sequence by combining Hadamard-encoded multipulses (HEM) with fundamental frequency bandpass filter (i.e., filter centered on transmit frequency). HEM consecutively emits multipulses encoded by a second-order Hadamard matrix in each of the two transmission events (i.e., pulse-echo events), as opposed to conventional CEUS methods which emit individual pulses in two separate transmission events (i.e., pulse inversion (PI), amplitude modulation (AM), and PIAM). In HEM imaging, the microbubble responses can be improved by the longer transmit pulse, and the tissue harmonics can be suppressed by the fundamental frequency filter, leading to significantly improved contrast-to-tissue ratio (CTR) and signal-to-noise ratio (SNR). In addition, the fast polarity change between consecutive coded pulse emissions excites strong nonlinear microbubble echoes, further enhancing the CEUS image quality. The spatial resolution of HEM image is compromised as compared to other microbubble imaging methods due to the longer transmit pulses and the lower imaging frequency (i.e., fundamental frequency). However, the resolution loss was shown to be negligible and could be offset by the significantly enhanced CTR, SNR, and penetration depth. These properties of HEM can potentially facilitate robust CEUS imaging for many clinical applications, especially for deep abdominal organs and heart.
Heterogeneity in Short Gamma-Ray Bursts
NASA Technical Reports Server (NTRS)
Norris, Jay P.; Gehrels Neil; Scargle, Jeffrey D.
2011-01-01
We analyze the Swift/BAT sample of short gamma-ray bursts, using an objective Bayesian Block procedure to extract temporal descriptors of the bursts' initial pulse complexes (IPCs). The sample comprises 12 and 41 bursts with and without extended emission (EE) components, respectively. IPCs of non-EE bursts are dominated by single pulse structures, while EE bursts tend to have two or more pulse structures. The medians of characteristic timescales - durations, pulse structure widths, and peak intervals - for EE bursts are factors of approx 2-3 longer than for non-EE bursts. A trend previously reported by Hakkila and colleagues unifying long and short bursts - the anti-correlation of pulse intensity and width - continues in the two short burst groups, with non-EE bursts extending to more intense, narrower pulses. In addition we find that preceding and succeeding pulse intensities are anti-correlated with pulse interval. We also examine the short burst X-ray afterglows as observed by the Swift/XRT. The median flux of the initial XRT detections for EE bursts (approx 6 X 10(exp -10) erg / sq cm/ s) is approx > 20 x brighter than for non-EE bursts, and the median X-ray afterglow duration for EE bursts (approx 60,000 s) is approx 30 x longer than for non-EE bursts. The tendency for EE bursts toward longer prompt-emission timescales and higher initial X-ray afterglow fluxes implies larger energy injections powering the afterglows. The longer-lasting X-ray afterglows of EE bursts may suggest that a significant fraction explode into more dense environments than non-EE bursts, or that the sometimes-dominant EE component efficiently p()wers the afterglow. Combined, these results favor different progenitors for EE and non-EE short bursts.
Changes in Pelvic Incidence, Pelvic Tilt, and Sacral Slope in Situations of Pelvic Rotation.
Jin, Hai-Ming; Xu, Dao-Liang; Xuan, Jun; Chen, Jiao-Xiang; Chen, Kai; Goswami, Amit; Chen, Yu; Kong, Qiu-Yan; Wang, Xiang-Yang
2017-08-01
Digitally reconstructed radiograph-based study. Using a computer-based method to determine what degree of pelvic rotation is acceptable for measuring the pelvic incidence (PI), pelvic tilt (PT), and sacral slope (SS). The effectiveness of a geometrical formula used to calculate the angle of pelvic rotation proposed in a previous article was assessed. It is unclear whether PI, PT, and SS are valid with pelvic rotation while acquiring a radiograph. Ten 3-dimensionally reconstructed models were established with software and placed in a neutral orientation to orient all of the bones in a standing position. Next, 140 digitally reconstructed radiographs were obtained by rotating the models around the longitudinal axis of each pelvis in the software from 0 to 30 degrees at 2.5-degree intervals. PI, PT, and SS were measured. The rotation angle was considered to be acceptable when the change in the measured angle (compared with the "correct" position) was <6 degrees. The rotation angle (α) on the images was calculated by a geometrical formula. Consistency between the measured value and the set angle was assessed. The acceptable maximum angle of rotation for reliable measurements of PI was 17.5 degrees, and the changes in PT and SS were within an acceptable range (<6 degrees) when the pelvic rotation increased from 0 to 30 degrees. The effectiveness of the geometrical formula was shown by the consistency between the set and the calculated rotation angles of the pelvis (intraclass correlation coefficient=0.99). Our study provides insight into the influence of pelvic rotation on the PI, PT, and SS. PI changes with pelvic rotation. The acceptable maximum angle for reliable values of PI, PT, and SS was 17.5 degrees, and the rotation angle of the pelvis on a lateral spinopelvic radiograph can be calculated reliably.
Doerry, Armin W.
2004-07-20
Movement of a GMTI radar during a coherent processing interval over which a set of radar pulses are processed may cause defocusing of a range-Doppler map in the video signal. This problem may be compensated by varying waveform or sampling parameters of each pulse to compensate for distortions caused by variations in viewing angles from the radar to the target.
"Bird Song Metronomics": Isochronous Organization of Zebra Finch Song Rhythm.
Norton, Philipp; Scharff, Constance
2016-01-01
The human capacity for speech and vocal music depends on vocal imitation. Songbirds, in contrast to non-human primates, share this vocal production learning with humans. The process through which birds and humans learn many of their vocalizations as well as the underlying neural system exhibit a number of striking parallels and have been widely researched. In contrast, rhythm, a key feature of language, and music, has received surprisingly little attention in songbirds. Investigating temporal periodicity in bird song has the potential to inform the relationship between neural mechanisms and behavioral output and can also provide insight into the biology and evolution of musicality. Here we present a method to analyze birdsong for an underlying rhythmic regularity. Using the intervals from one note onset to the next as input, we found for each bird an isochronous sequence of time stamps, a "signal-derived pulse," or pulse(S), of which a subset aligned with all note onsets of the bird's song. Fourier analysis corroborated these results. To determine whether this finding was just a byproduct of the duration of notes and intervals typical for zebra finches but not dependent on the individual duration of elements and the sequence in which they are sung, we compared natural songs to models of artificial songs. Note onsets of natural song deviated from the pulse(S) significantly less than those of artificial songs with randomized note and gap durations. Thus, male zebra finch song has the regularity required for a listener to extract a perceived pulse (pulse(P)), as yet untested. Strikingly, in our study, pulses(S) that best fit note onsets often also coincided with the transitions between sub-note elements within complex notes, corresponding to neuromuscular gestures. Gesture durations often equaled one or more pulse(S) periods. This suggests that gesture duration constitutes the basic element of the temporal hierarchy of zebra finch song rhythm, an interesting parallel to the hierarchically structured components of regular rhythms in human music.
“Bird Song Metronomics”: Isochronous Organization of Zebra Finch Song Rhythm
Norton, Philipp; Scharff, Constance
2016-01-01
The human capacity for speech and vocal music depends on vocal imitation. Songbirds, in contrast to non-human primates, share this vocal production learning with humans. The process through which birds and humans learn many of their vocalizations as well as the underlying neural system exhibit a number of striking parallels and have been widely researched. In contrast, rhythm, a key feature of language, and music, has received surprisingly little attention in songbirds. Investigating temporal periodicity in bird song has the potential to inform the relationship between neural mechanisms and behavioral output and can also provide insight into the biology and evolution of musicality. Here we present a method to analyze birdsong for an underlying rhythmic regularity. Using the intervals from one note onset to the next as input, we found for each bird an isochronous sequence of time stamps, a “signal-derived pulse,” or pulseS, of which a subset aligned with all note onsets of the bird's song. Fourier analysis corroborated these results. To determine whether this finding was just a byproduct of the duration of notes and intervals typical for zebra finches but not dependent on the individual duration of elements and the sequence in which they are sung, we compared natural songs to models of artificial songs. Note onsets of natural song deviated from the pulseS significantly less than those of artificial songs with randomized note and gap durations. Thus, male zebra finch song has the regularity required for a listener to extract a perceived pulse (pulseP), as yet untested. Strikingly, in our study, pulsesS that best fit note onsets often also coincided with the transitions between sub-note elements within complex notes, corresponding to neuromuscular gestures. Gesture durations often equaled one or more pulseS periods. This suggests that gesture duration constitutes the basic element of the temporal hierarchy of zebra finch song rhythm, an interesting parallel to the hierarchically structured components of regular rhythms in human music. PMID:27458334
Pulsed growth of fungal hyphal tips.
López-Franco, R; Bartnicki-Garcia, S; Bracker, C E
1994-12-06
Somatic fungal hyphae are generally assumed to elongate at steady linear rates when grown under constant environmental conditions with ample nutrients. However, patterns of pulsed hyphal elongation were detected during apparent steady growth of hyphal tips in fungi from several major taxonomic groups (Oomycetes, Pythium aphanidermatum and Saprolegnia ferax; Zygomycetes, Gilbertella persicaria; Deuteromycetes, Trichoderma viride; Ascomycetes, Neurospora crassa and Fusarium culmorum; Basidiomycetes, Rhizoctonia solani). Growing hyphal tips were recorded with video-enhanced phase-contrast microscopy at high magnification, and digital images were measured at very short time intervals (1-5 s). In all fungi tested, the hyphal elongation rate was never perfectly steady but fluctuated continuously with alternating periods of fast and slow growth at more or less regular intervals. Pulsed growth was observed in fungi differing in cell diameter, overall growth rate, taxonomic position, and presence and pattern of Spitzenkörper organization, suggesting that this is a general phenomenon. Frequency and amplitude of the pulses varied among the test organisms. T. viride and N. crassa showed the most frequent pulses (average of 13-14 per min), and F. culmorum the least frequent (2.7 per min). Average pulse amplitude varied from 0.012 microns/s for F. culmorum to 0.068 microns/s for G. persicaria. In F. culmorum and T. viride, the fast phase of the growth pulses was correlated with the merger of satellite Spitzenkörper with the main Spitzenkörper. These findings are consistent with a causal relationship between fluctuations in the overall rate of secretory vesicle delivery/discharge at the hyphal apex and the fluctuations in hyphal elongation rate.
Adam, Nadir; Sorensen, Victor; Skinner, Ruby
2015-01-01
Traumatic intestinal injuries are less common with blunt compared to penetrating mechanisms of trauma and blunt injuries are often associated with diagnostic delays. The purpose of this study is to evaluate differences in the characteristics and outcomes between blunt and penetrating intestinal injuries to facilitate insight into optimal recognition and management. A retrospective analysis of trauma admissions from January 2009 to June 2011 was performed. Patient demographics, ISS, early shock, injury type, timing to OR, blood loss and transfusions, surgical management, infections, EC fistulas, enteric leaks, LOS and mortality were compared. Demographics - There was 3866 blunt admissions and 966 penetrating admissions to our level II trauma centre (Total n=4832) during this interval. The final study group comprised n=131 patients treated for intestinal injuries. Blunt n=54 (BI) vs. penetrating (PI) n=77. Age was similar between the groups: (BI 34 SD 12 vs. PI 30 SD 12). Comorbid conditions were similar as were ED hypotension and blood transfusions. Blunt mechanisms had higher ISS; BI (20 SD 14) vs. PI (16 SD 12), p=0.08 and organ specific injury scales were higher in blunt injuries. Operative Management - Time to operation was higher in BI: (500 SD 676min vs. PI 110 SD 153min, p=0.01). The use of an open abdomen technique was higher for BI: n=19 (35%) vs. PI: n=5 (6%), p=<0.001, as well as delayed intestinal repair in damage control cases. Outcomes - Anastomotic leaks were more prevalent in BI: n=4 (7%) vs. PI: n=2 (3%), p=0.38. Enteric fistulas were: (BI n=8 (15%), vs. PI n=2 (3%), p=0.02). Surgical site infections and other nosocomial infections were: (BI n=11 (20%) vs. PI n=4 (5%), p=0.02), (BI n=11 (20%) vs. PI n=2 (3%), p=0.002), respectively. Hospital and ICU LOS was: (BI=20 SD 14 vs. PI=11 SD 11, p=0.001), (BI=10 SD 10 vs. PI=5 SD 5, p=0.01) respectively. These differences were reflected in higher hospital charges in BI. Blunt and penetrating intestinal injury patterns have high injury severity. Significant operative delays occurred in the blunt injury group as well as, anastomotic failures, enteric fistulas, nosocomial infections, and higher cost. These features underscore the complexity of blunt injury patterns and warrant vigilant injury recognition to improve outcomes. Copyright © 2014 Elsevier Ltd. All rights reserved.
Quasi-steady-state air plasma channel produced by a femtosecond laser pulse sequence
Lu, Xin; Chen, Shi-You; Ma, Jing-Long; Hou, Lei; Liao, Guo-Qian; Wang, Jin-Guang; Han, Yu-Jing; Liu, Xiao-Long; Teng, Hao; Han, Hai-Nian; Li, Yu-Tong; Chen, Li-Ming; Wei, Zhi-Yi; Zhang, Jie
2015-01-01
A long air plasma channel can be formed by filamentation of intense femtosecond laser pulses. However, the lifetime of the plasma channel produced by a single femtosecond laser pulse is too short (only a few nanoseconds) for many potential applications based on the conductivity of the plasma channel. Therefore, prolonging the lifetime of the plasma channel is one of the key challenges in the research of femtosecond laser filamentation. In this study, a unique femtosecond laser source was developed to produce a high-quality femtosecond laser pulse sequence with an interval of 2.9 ns and a uniformly distributed single-pulse energy. The metre scale quasi-steady-state plasma channel with a 60–80 ns lifetime was formed by such pulse sequences in air. The simulation study for filamentation of dual femtosecond pulses indicated that the plasma channel left by the previous pulse was weakly affected the filamentation of the next pulse in sequence under our experimental conditions. PMID:26493279
Nanosecond electric pulses modulate skeletal muscle calcium dynamics and contraction
NASA Astrophysics Data System (ADS)
Valdez, Chris; Jirjis, Michael B.; Roth, Caleb C.; Barnes, Ronald A.; Ibey, Bennett L.
2017-02-01
Irreversible electroporation therapy is utilized to remove cancerous tissues thru the delivery of rapid (250Hz) and high voltage (V) (1,500V/cm) electric pulses across microsecond durations. Clinical research demonstrated that bipolar (BP) high voltage microsecond pulses opposed to monophasic waveforms relieve muscle contraction during electroporation treatment. Our group along with others discovered that nanosecond electric pulses (nsEP) can activate second messenger cascades, induce cytoskeletal rearrangement, and depending on the nsEP duration and frequency, initiate apoptotic pathways. Of high interest across in vivo and in vitro applications, is how nsEP affects muscle physiology, and if nuances exist in comparison to longer duration electroporation applications. To this end, we exposed mature skeletal muscle cells to monopolar (MP) and BP nsEP stimulation across a wide range of electric field amplitudes (1-20 kV/cm). From live confocal microscopy, we simultaneously monitored intracellular calcium dynamics along with nsEP-induced muscle movement on a single cell level. In addition, we also evaluated membrane permeability with Yo-PRO-1 and Propidium Iodide (PI) across various nsEP parameters. The results from our findings suggest that skeletal muscle calcium dynamics, and nsEP-induced contraction exhibit exclusive responses to both MP and BP nsEP exposure. Overall the results suggest in vivo nsEP application may elicit unique physiology and field applications compared to longer pulse duration electroporation.
Chen, Xiaodong; Chen, Minglong; Wang, Yingying; Yang, Bing; Ju, Weizhu; Zhang, Fengxiang; Cao, Kejiang
2016-01-01
Abstract We sought to investigate variation of atrial electromechanical interval after catheter ablation procedure in patients with persistent atrial fibrillation using pulse Doppler (PW) and pulse tissue Doppler imaging (PW-TDI). A total of 25 consecutive in-patients with persistent atrial fibrillation, who restored sinus rhythm after ablation procedure, were recruited in our cardiac center. Echocardiography was performed on each patient at 2 hours, 1 day, 5 days, 1 month and 3 months after the ablation therapy, and atrial electromechanical delay was measured simultaneously by PW and PW-TDI. There was no significant difference between PW and TDI in measuring atrial electromechanical delay. However, at postoperative 2 hours, peak A detection rates were mathematically but nonsignificantly greater by PW-TDI than by PW. Second, there was a significant decreasing trend in atrial electromechanical interval from postoperative 2 hours to 3 months, but only postoperative 2-hour atrial electromechanical interval was significantly greater than atrial electromechanical interval at other time. Lastly, patients without postoperative 2-hour atrial electromechanical interval had a significantly longer duration of atrial fibrillation as compared to those with postoperative 2-hour atrial electromechanical interval, by the PW or by PW-TDI, respectively. In patients with persistent atrial fibrillation, atrial electromechanical interval may decrease significantly within the first 24 hours after ablation but remain consistent later, and was significantly related to patients’ duration of atrial fibrillation. Atrial electromechanical interval, as a potential predicted factor, is recommended to be measured by either PW or TDI after 24 hours, when patients had recovered sinus rhythm by radiofrequency ablation. PMID:27924066
Week 96 results of the randomized, multicentre Maraviroc Switch (MARCH) study.
Pett, S L; Amin, J; Horban, A; Andrade-Villanueva, J; Losso, M; Porteiro, N; Madero, J S; Belloso, W; Tu, E; Silk, D; Kelleher, A; Harrigan, R; Clark, A; Sugiura, W; Wolff, M; Gill, J; Gatell, J; Clarke, A; Ruxrungtham, K; Prazuck, T; Kaiser, R; Woolley, I; Alberto Arnaiz, J; Cooper, D; Rockstroh, J K; Mallon, P; Emery, S
2018-01-01
The Maraviroc Switch (MARCH) study week 48 data demonstrated that maraviroc, a chemokine receptor-5 (CCR5) inhibitor, was a safe and effective switch for the ritonavir-boosted protease inhibitor (PI/r) component of a two nucleos(t)ide reverse transcriptase inhibitor [N(t)RTI] plus PI/r-based antiretroviral regimen in patients with R5-tropic virus. Here we report the durability of this finding. MARCH, an international, multicentre, randomized, 96-week open-label switch study, enrolled HIV-1-infected adults with R5-tropic virus who were stable (> 24 weeks) and virologically suppressed [plasma viral load (pVL) < 50 HIV-1 RNA copies/mL]. Participants were randomized to continue their current PI/r-based regimen (PI/r) or to switch to MVC plus two N(t)RTIs (MVC) (1:2 randomization). The primary endpoint was the difference in the proportion with pVL < 200 copies/mL at 96 weeks. The switch arm was defined as noninferior if the lower limit of the 95% confidence interval (CI) for the difference was < -12% in the intention-to-treat (ITT) population. Safety endpoints (the difference in the mean change from baseline or a comparison of proportions) were analysed as key secondary endpoints. Eighty-two (PI/r) and 156 (MVC) participants were randomized and included in the ITT analysis; 71 (87%) and 130 (83%) were in follow-up and on therapy at week 96. At week 96, 89.0% and 90.4% in the PI/r and MVC arms, respectively, had pVL < 50 copies/mL (95% CI -6.6, 10.2). Moreover, in those switching away from PI/r, there were significant reductions in mean total cholesterol (differences 0.31 mmol/L; P = 0.02) and triglycerides (difference 0.44 mmol/L; P < 0.001). Changes in CD4 T-cell count, renal function, and serious and nonserious adverse events were similar in the two arms. MVC as a switch for a PI/r is safe and effective at maintaining virological suppression while having significant lipid benefits over 96 weeks. © 2017 British HIV Association.
Autogenerator of beams of charged particles
Adler, Richard J.; Mazarakis, Michael G.; Miller, Robert B.; Shope, Steven L.; Smith, David L.
1986-01-01
An autogenerating apparatus provides secondary intense relativistic current beam pulses in response to an injected beam pulse. One or more electromagnetic energy storage devices are provided in conjunction with gaps along a beam propagation path for the injected beam pulse. For injected beam pulses which are no longer than double the transit time of electromagnetic waves within the storage devices (which may be resonant cavities), distinct secondary beam pulses are generated by each of the energy storage devices. The beam propagation path, together with the one or more gaps provided therein, operates as a pulse forming transmission line cavity, in which the separate cavities associated with the gaps provide delays for electromagnetic waves generated at the gaps. After doubly traversing the cavity, the electromagnetic waves cause the gap to generate the secondary beam pulses, which are thus delayed by a time interval equal to the double transit time for the induced wave within the cavity.
Autogenerator of beams of charged particles
Adler, R.J.; Mazarakis, M.G.; Miller, R.M.; Shope, S.L.; Smith, D.L.
1983-10-31
An autogenerating apparatus provides secondary intense relativistic current beam pulses in response to an injected beam pulse. One or more electromagnetic energy storage devices are provided in conjunction with gaps along a beam propagation path for the injected beam pulse. For injected beam pulses which are no longer than double the transit time of electromagnetic waves within the storage devices (which may be resonant cavities), distinct secondary beam pulses are generated by each of the energy storage devices. The beam propagation path, together with the one or more gaps provided therein, operates as a pulse forming transmission line cavity, in which the separate cavities associated with the gaps provide delays for electromagnetic waves generated at the gaps. After doubly traversing the cavity, the electromagnetic waves cause the gap to generate the secondary beam pulses, which are thus delayed by a time interval equal to the double transit time for the induced wave within the cavity.
Moving target detection for frequency agility radar by sparse reconstruction
NASA Astrophysics Data System (ADS)
Quan, Yinghui; Li, YaChao; Wu, Yaojun; Ran, Lei; Xing, Mengdao; Liu, Mengqi
2016-09-01
Frequency agility radar, with randomly varied carrier frequency from pulse to pulse, exhibits superior performance compared to the conventional fixed carrier frequency pulse-Doppler radar against the electromagnetic interference. A novel moving target detection (MTD) method is proposed for the estimation of the target's velocity of frequency agility radar based on pulses within a coherent processing interval by using sparse reconstruction. Hardware implementation of orthogonal matching pursuit algorithm is executed on Xilinx Virtex-7 Field Programmable Gata Array (FPGA) to perform sparse optimization. Finally, a series of experiments are performed to evaluate the performance of proposed MTD method for frequency agility radar systems.
Moving target detection for frequency agility radar by sparse reconstruction.
Quan, Yinghui; Li, YaChao; Wu, Yaojun; Ran, Lei; Xing, Mengdao; Liu, Mengqi
2016-09-01
Frequency agility radar, with randomly varied carrier frequency from pulse to pulse, exhibits superior performance compared to the conventional fixed carrier frequency pulse-Doppler radar against the electromagnetic interference. A novel moving target detection (MTD) method is proposed for the estimation of the target's velocity of frequency agility radar based on pulses within a coherent processing interval by using sparse reconstruction. Hardware implementation of orthogonal matching pursuit algorithm is executed on Xilinx Virtex-7 Field Programmable Gata Array (FPGA) to perform sparse optimization. Finally, a series of experiments are performed to evaluate the performance of proposed MTD method for frequency agility radar systems.
NASA Astrophysics Data System (ADS)
Geng, Lijie; Zhang, Zhifeng; Zhai, Yusheng; Su, Yuling; Zhou, Fanghua; Qu, Yanchen; Zhao, Weijiang
2016-08-01
Temporal behavior of the pump pulses, residual pump pulses, and THz pulses for optically pumped D2O gas molecules was investigated by using a tunable TEA CO2 laser as the pumping source. The pulse profiles of pump laser pulses, residual pump pulses, and the THz output pulses were measured, simultaneously, at several different gas pressures. For THz pulse, the pulse delay between the THz pulse and the pump pulse was observed and the delay time was observed to increase from 40 to 70 ns with an increase in gas pressure from 500 to 1700 Pa. Both THz pulse broadening and compression were observed, and the pulse broadening effect transformed to the compression effect with increasing the gas pressure. For the residual pump pulse, the full width at half maximum (FWHM) of the main pulse decreased with increasing gas pressure, and the main pulse disappeared at high gas pressures. The secondary pulses were observed at high gas pressure, and the time intervals of about 518 and 435 ns were observed between the THz output pulse and the secondary residual pump pulse at the pressure of 1400 Pa and 1700 Pa, from which the vibrational relaxation time constants of about 5.45 and 5.55 μs Torr were obtained.
NASA Astrophysics Data System (ADS)
Furuki, Makoto; Tian, Minquan; Sato, Yasuhiro; Pu, Lyong Sun; Tatsuura, Satoshi; Wada, Osamu
2000-07-01
We applied time-to-space conversion using femtosecond nonlinear-optical response of squarylium-dye (SQ) J-aggregates film. A pump pulse and a train of four probe pulses were illuminated on the same area (10 mm φ) of the film in direction of oblique and normal to the film plane, respectively. Due to the oblique illumination, the pump pulse met probe pulses (interval time: 1 ps) at separate places. The film picked out part of each probe pulse by its transmittance change, which was observed for a transmitted image of spatially separated four lines. Response time of the SQ J aggregates is enough for the single-shot 1 THz demultiplexing.
Diagnostics of Laser Produced Plume Under Carbon Nanotube Growth Conditions
NASA Technical Reports Server (NTRS)
Arepalli, Sivaram; Nikolaev, Pavel; Holmes, William; Scott, Carl D.
1999-01-01
This paper presents diagnostic data obtained from the plume of a graphite composite target during carbon nanotube production by the double-pulse laser oven method. The insitu emission spectrum (300 to 650 nm) is recorded at different locations upstream of the target and at different delay times from the lasers (IR and green). Spectral features are identified as emissions from C2 (Swan System: a (sup 3)pi(sub g) - delta (sup 3)pi(sub u) and C3 (Comet Head System: A (sup 1)pi(sub u) - chi (sup 1)sigma(sub u) (sup +). Experimental spectra are compared with computed spectra to estimate vibrational temperatures of excited state C2 in the range of 2500 to 4000 kappa The temporal evolution of the 510 nm band of C2 is monitored for two target positions in various locations which shows confinement of the plume in the inner tube and increase in plume velocity with temperature. The excitation spectra of C2 are obtained by using a dye laser to pump the (0,1) transition of the Swan System and collecting the Laser Induced Fluorescence signal from C2 These are used to obtain "ground-state" rotational and vibrational temperatures which are close to the oven temperature. Images of the plume are also collected and are compared with the spectral measurements.
The association between air pollution and mortality in Thailand
Guo, Yuming; Li, Shanshan; Tawatsupa, Benjawan; Punnasiri, Kornwipa; Jaakkola, Jouni J. K.; Williams, Gail
2014-01-01
Bayesian statistical inference with a case-crossover design was used to examine the effects of air pollutants {Particulate matter <10 μm in aerodynamic diameter (PM10), sulphur dioxide (SO2), and ozone (O3)} on mortality. We found that all air pollutants had significant short-term impacts on non-accidental mortality. An increase of 10 μg/m3 in PM10, 10 ppb in O3, 1 ppb in SO2 were associated with a 0.40% (95% posterior interval (PI): 0.22, 0.59%), 0.78% (95% PI: 0.20, 1.35%) and 0.34% (95% PI: 0.17, 0.50%) increase of non-accidental mortality, respectively. O3 air pollution is significantly associated with cardiovascular mortality, while PM10 is significantly related to respiratory mortality. In general, the effects of all pollutants on all mortality types were higher in summer and winter than those in the rainy season. This study highlights the effects of exposure to air pollution on mortality risks in Thailand. Our findings support the Thailand government in aiming to reduce high levels of air pollution. PMID:24981315
The association between air pollution and mortality in Thailand.
Guo, Yuming; Li, Shanshan; Tawatsupa, Benjawan; Punnasiri, Kornwipa; Jaakkola, Jouni J K; Williams, Gail
2014-07-01
Bayesian statistical inference with a case-crossover design was used to examine the effects of air pollutants {Particulate matter <10 μm in aerodynamic diameter (PM10), sulphur dioxide (SO₂), and ozone (O₃)} on mortality. We found that all air pollutants had significant short-term impacts on non-accidental mortality. An increase of 10 μg/m(3) in PM10, 10 ppb in O₃, 1 ppb in SO₂ were associated with a 0.40% (95% posterior interval (PI): 0.22, 0.59%), 0.78% (95% PI: 0.20, 1.35%) and 0.34% (95% PI: 0.17, 0.50%) increase of non-accidental mortality, respectively. O₃ air pollution is significantly associated with cardiovascular mortality, while PM10 is significantly related to respiratory mortality. In general, the effects of all pollutants on all mortality types were higher in summer and winter than those in the rainy season. This study highlights the effects of exposure to air pollution on mortality risks in Thailand. Our findings support the Thailand government in aiming to reduce high levels of air pollution.
Sidibé, Cheick Abou Kounta; Grosbois, Vladimir; Thiaucourt, François; Niang, Mamadou; Lesnoff, Matthieu; Roger, François
2012-08-01
A Bayesian approach, allowing for conditional dependence between two tests was used to estimate without gold standard the sensitivities of complement fixation test (CFT) and competitive enzyme-linked immunosorbent assay test (cELISA) and the serological prevalence of CBPP in a cattle population of the Central Delta of the Niger River in Mali, where CBPP is enzootic and the true prevalence and animals serological state were unknown. A significant difference (P = 0.99) was observed between the sensitivities of the two tests, estimated at 73.7% (95% probability interval [PI], 63.4-82.7) for cELISA and 42.3% (95% PI, 33.3-53.7) for CFT. Individual-level serological prevalence in the study population was estimated at 14.1% (95% PI, 10.8-16.9). Our results indicate that in enzootic areas, cELISA performs better in terms of sensitivity than CFT. However, negative conditional sensitivity dependence between the two tests was detected, implying that to achieve maximum sensitivity, the two tests should be applied in parallel.
Qiao, Wenjun; Tang, Xiaoqi; Zheng, Shiqi; Xie, Yuanlong; Song, Bao
2016-09-01
In this paper, an adaptive two-degree-of-freedom (2Dof) proportional-integral (PI) controller is proposed for the speed control of permanent magnet synchronous motor (PMSM). Firstly, an enhanced just-in-time learning technique consisting of two novel searching engines is presented to identify the model of the speed control system in a real-time manner. Secondly, a general formula is given to predict the future speed reference which is unavailable at the interval of two bus-communication cycles. Thirdly, the fractional order generalized predictive control (FOGPC) is introduced to improve the control performance of the servo drive system. Based on the identified model parameters and predicted speed reference, the optimal control law of FOGPC is derived. Finally, the designed 2Dof PI controller is auto-tuned by matching with the optimal control law. Simulations and real-time experimental results on the servo drive system of PMSM are provided to illustrate the effectiveness of the proposed strategy. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.
Mathematics of pulsed vocalizations with application to killer whale biphonation.
Brown, Judith C
2008-05-01
Formulas for the spectra of pulsed vocalizations for both the continuous and discrete cases are rigorously derived from basic formulas for Fourier analysis, a topic discussed qualitatively in Watkins' classic paper on "the harmonic interval" ["The harmonic interval: Fact or artifact in spectral analysis of pulse trains," in Marine Bioacoustics 2, edited by W. N. Tavogla (Pergamon, New York, 1967), pp. 15-43]. These formulas are summarized in a table for easy reference, along with most of the corresponding graphs. The case of a "pulse tone" is shown to involve multiplication of two temporal wave forms, corresponding to convolution in the frequency domain. This operation is discussed in detail and shown to be equivalent to a simpler approach using a trigonometric formula giving sum and difference frequencies. The presence of a dc component in the temporal wave form, which implies physically that there is a net positive pressure at the source, is discussed, and examples of the corresponding spectra are calculated and shown graphically. These have application to biphonation (two source signals) observed for some killer whale calls and implications for a source mechanism. A MATLAB program for synthesis of a similar signal is discussed and made available online.
Application Of Pulsed Laser Holography To Nondestructive Testing Of Aircraft Structures
NASA Astrophysics Data System (ADS)
Fagot, Hubert; Smigielski, Paul; Arnaud, Jean-Louis
1983-03-01
Subsequently to laboratory tests, experiments were conducted on an aircraft undergoing maintenance in order to assess the possible uses of holographic interferometry for non-destructive testing of large aircraft structures. A double ruby laser was used delivering two pulses with a duration of 20 ns each. The two pulses are separated by an arbitrary time interval At which is determined as a function of both the amplitude and frequency of the surface displacement. Shocks of the order of 100 mJ cause the structure under investigation to vibrate, the time interval At thereby ranging from 10 to 100 ps for a delay of a few ms after shock initiation. The method used is relatively insensitive to environmental disturbances. Although the laser delivers pulses of light of less than 100 mJ in energy, it is possible to visualize a field of 0.5 x1 m. Some results will be reported which have been obtained at the lower surface of an aerofoil, on a wheel well and on an air-brake. Finally a brief review will be made on the improvements envisaged on both the laser and the recording method in order to obtain an operational system for holographic non-destructive testing.
RF priming of a long pulse relativistic magnetron
NASA Astrophysics Data System (ADS)
White, William Michael
Rapid startup, increased pulsewidth and mode locking of magnetrons have been demonstrated experimentally on a relativistic magnetron by radio frequency (RF) priming. Experiments utilize a -300 kV, 2-8 kA, 300-500 ns electron beam to drive a Titan 6-vane relativistic magnetron (˜100 MW output power). The RF priming source is a 100 kW pulsed magnetron operating at 1.27-1.32 GHz. Tuning stubs were utilized in the Titan structure to adjust the operating frequency of the relativistic magnetron pi-mode upward by 30%. The tuning was guided by simulation in the MAGIC 3D code and experimental cold tests including a mapping of the azimuthal electric field inside the relativistic magnetron structure. The most successful tuning geometry was that of a standard anode resonant structure, but RF priming experiments were performed on a rising-sun structure as well. The Time Frequency Analysis (TFA) program was used to directly observe the effects of RF priming on the relativistic magnetron. RF priming was successful in decreasing mode competition by suppressing the generation of the 2pi/3-mode power by 41%. RF priming experiments were also successful in increasing microwave pulsewidth by 12% and decreasing microwave output delay by 22%. These improvements were observed while operating in a priming regime not satisfying Adler's Relation. Overall, the improvements made to the performance of the relativistic magnetron were modest because of the low priming power available (50-250 kW).
Beam shaping to provide round and square-shaped beams in optical systems of high-power lasers
NASA Astrophysics Data System (ADS)
Laskin, Alexander; Laskin, Vadim
2016-05-01
Optical systems of modern high-power lasers require control of irradiance distribution: round or square-shaped flat-top or super-Gaussian irradiance profiles are optimum for amplification in MOPA lasers and for thermal load management while pumping of crystals of solid-state ultra-short pulse lasers to control heat and minimize its impact on the laser power and beam quality while maximizing overall laser efficiency, variable profiles are also important in irradiating of photocathode of Free Electron lasers (FEL). It is suggested to solve the task of irradiance re-distribution using field mapping refractive beam shapers like piShaper. The operational principle of these devices presumes transformation of laser beam intensity from Gaussian to flat-top one with high flatness of output wavefront, saving of beam consistency, providing collimated output beam of low divergence, high transmittance, extended depth of field, negligible residual wave aberration, and achromatic design provides capability to work with ultra-short pulse lasers having broad spectrum. Using the same piShaper device it is possible to realize beams with flat-top, inverse Gauss or super Gauss irradiance distribution by simple variation of input beam diameter, and the beam shape can be round or square with soft edges. This paper will describe some design basics of refractive beam shapers of the field mapping type and optical layouts of their applying in optical systems of high-power lasers. Examples of real implementations and experimental results will be presented as well.
NASA Astrophysics Data System (ADS)
Khan, Mansoor; Yong, Wang; Mustafa, Ehtasham
2017-07-01
After the rapid advancement in the field of power electronics devices and drives for last few decades, there are different kinds of Pulse Width Modulation techniques which have been brought to the market. The applications ranging from industrial appliances to military equipment including the home appliances. The vey common application for the PWM is three phase voltage source inverter, which is used to convert DC to AC in the homes to supply the power to the house in case electricity failure, usually named as Un-interrupted Power Supply. In this paper Space Vector Pulse Width Modulation techniques is discussed and analysed under the control technique named as Field Oriented Control. The working and implementation of this technique has been studied by implementing on the three phase bridge inverter. The technique is used to control the Permanente Magnet Synchronous Motor. The drive system is successfully implemented in MATLAB/Simulink using the mathematical equation and algorithm to achieve the satisfactory results. PI type of controller is used to tuned ers of the motothe parametr i.e. torque and current.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xin, G. G.; Ye, D. F.; Graduate School, China Academy of Engineering Physics, Beijing 100088
2010-12-15
In the present paper, we investigate the correlated electron emission of atoms irradiated by a few-cycle laser pulse, with emphasis on the correlated longitudinal momentum spectra. We find that the spectra show clear v-shaped structures, in analogy to what was observed recently in long-pulse experiments. Moreover, the patterns of the spectra depend sensitively on the carrier-envelope phase as well as the laser intensity. The v-shaped structure is more pronounced at lower and higher intensities and becomes obscure at medium intensity. At a lower intensity, upon change of the phase from 0 to {pi}/2, the v-shaped structure shifts from the firstmore » quadrant to the third quadrant and the ratios between the double ionization yields in the first and third quadrants are found to increase by a few orders of magnitude. The semiclassical rescattering model is exploited in the preceding calculations and the underlying mechanisms are uncovered by analyzing the subcycle dynamics of classical trajectories.« less
Precision control of carrier-envelope phase in grating based chirped pulse amplifiers.
Li, Chengquan; Moon, Eric; Mashiko, Hiroki; Nakamura, Christopher M; Ranitovic, Predrag; Maharjan, Chakra M; Cocke, C Lewis; Chang, Zenghu; Paulus, Gerhard G
2006-11-13
It is demonstrated that the carrier-envelope (CE) phase of pulses from a high power ultrafast laser system with a grating-based stretcher and compressor can be stabilized to a root mean square (rms) value of 180 mrad over almost 2 hours, excluding a brief re-locking period. The stabilization was accomplished via feedback control of the grating separation in the stretcher. It shows that the long term CE phase stability of a grating based chirped pulse amplification system can be as good as that of lasers using a glass-block stretcher and a prism pair compressor. Moreover, by adjusting the grating separation to preset values, the relative CE phase could be locked to an arbitrary value in the range of 2pi. This method is better than using a pair of wedge plates to adjust the phase after the hollow-core fiber compressor. The CE phase stabilization after a hollow-core fiber compressor was confirmed by a CE-phase meter based on the measurement of the left-to-right asymmetry of electrons produced by above-threshold ionization.
[Influence of age on systolic and diastolic time intervals in normal individuals].
Soares-Costa, J T; Soares-Costa, T J; Santos, A J; Monteiro, A J
1991-12-01
To evaluate the influence of age (I) on the left ventricle (VE) systolic time intervals, the S2O interval, the pulse transmission time (TTP) and the relative amplitude of the a wave (Aa%) of the apexcardiogram (ACG) of normal individuals. 202 subjects considered as normal by clinical and electrocardiographic examinations were studied. Their age (I) was 38 +/- 13 years (average +/- 1 SD), being 125 male and 77 female. The electrocardiogram (ECG), phonocardiogram, ACG and carotid arterial pulse tracing (PC) were simultaneously recorded. The following intervals were determined: Electromechanical (IEM)--from the onset of QRS complex of the ECG to the ascending branch of the great wave of the ACG (A point); mechanical systole (SM)--from the A point of the ACG to the beginning of first high frequency vibration of the aortic component of the second heart sound (S2); ejection period (FE)--from the beginning of the anacrotic branch of the PC to the nadir of its dicrotic notch (ID); isovolumic contraction time (FIS)--subtracting FE duration to the SM duration; S2O interval--since S2 to the O point (nadir) of the ACG; Aa%--relation percentage expressed between a wave amplitude and total amplitude of the ACG; pulse transmission time--since S2 to ID. Statistically significant correlations (p less than 0.05) between I (years expressed) and the previously mentioned variables were investigated. It was possible to verify: a) the IEM and FIS intervals were not significantly correlated with I; b) the FE had a linear, positive and significant correlation with I (r = 0.222); c) the correlations between FE and heart rate (FC) were not significantly different between the considered age groups (14-34, 35-49, 50-69 years); d) the S2O interval had a linear, negative and significant correlation with FC (r = -0.196), and a linear, positive and significant correlation with I (r = 0.392); e) multiple regression equation between S2O, I and FC was: S2O = 70 - 0.36 x FC + 0.55 x I; f) the Aa% had a linear, positive and significant correlation with I (r = 0.252); g) TTP has a linear, negative and significant correlation with I (r = -0.793). a) The FE increases with I related probably to the afterload increasing that follows aging process; b) the S2O interval increases with I reflecting the elongation of the relaxing time that is associated to the senescence; c) the Aa% increases with I, expressing the reduction of the compliance of the VE associated to the aging; d) the TTP decreases with I related to the increasing of velocity of the pulse wave that follows senescence and is attributed to the increasing of the aortic stiffness.
Anomalous memory effect in the breakdown of low-pressure argon in a long discharge tube
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meshchanov, A. V.; Korshunov, A. N.; Ionikh, Yu. Z., E-mail: y.ionikh@spbu.ru
2015-08-15
The characteristics of breakdown of argon in a long tube (with a gap length of 75 cm and diameter of 2.8 cm) at pressures of 1 and 5 Torr and stationary discharge currents of 5–40 mA were studied experimentally. The breakdown was initiated by paired positive voltage pulses with a rise rate of ∼10{sup 8}–10{sup 9} V/s and duration of ∼1–10 ms. The time interval between pairs was varied in the range of Τ ∼ 0.1–1 s, and that between pulses in a pair was varied from τ = 0.4 ms to ≈Τ/2. The aim of this work was tomore » detect and study the so-called “anomalous memory effect” earlier observed in breakdown in nitrogen. The effect consists in the dynamic breakdown voltage in the second pulse in a pair being higher than in the first pulse (in contrast to the “normal” memory effect, in which the relation between the breakdown voltages is opposite). It is found that this effect is observed when the time interval between pairs of pulses is such that the first pulse in a pair is in the range of the normal memory effect of the preceding pair (under the given conditions, Τ ≈ 0.1–0.4 s). In this case, at τ ∼ 10 ms, the breakdown voltage of the second pulse is higher than the reduced breakdown voltage of the first pulse. Optical observations of the ionization wave preceding breakdown in a long tube show that, in the range of the anomalous memory effect and at smaller values of τ, no ionization wave is detected before breakdown in the second pulse. A qualitative interpretation of the experimental results is given.« less
Gong, Chunzhi; Tian, Xiubo; Yang, Shiqin; Fu, Ricky K Y; Chu, Paul K
2008-04-01
A novel power supply system that directly couples pulsed high voltage (HV) pulses and pulsed 13.56 MHz radio frequency (rf) has been developed for plasma processes. In this system, the sample holder is connected to both the rf generator and HV modulator. The coupling circuit in the hybrid system is composed of individual matching units, low pass filters, and voltage clamping units. This ensures the safe operation of the rf system even when the HV is on. The PSPICE software is utilized to optimize the design of circuits. The system can be operated in two modes. The pulsed rf discharge may serve as either the seed plasma source for glow discharge or high-density plasma source for plasma immersion ion implantation (PIII). The pulsed high-voltage glow discharge is induced when a rf pulse with a short duration or a larger time interval between the rf and HV pulses is used. Conventional PIII can also be achieved. Experiments conducted on the new system confirm steady and safe operation.
Longitudinal variation in pressure injury incidence among long-term aged care facilities.
Jorgensen, Mikaela; Siette, Joyce; Georgiou, Andrew; Westbrook, Johanna I
2018-05-04
To examine variation in pressure injury (PI) incidence among long-term aged care facilities and identify resident- and facility-level factors that explain this variation. Longitudinal incidence study using routinely-collected electronic care management data. A large aged care service provider in New South Wales and the Australian Capital Territory, Australia. About 6556 people aged 65 years and older who were permanent residents in 60 long-term care facilities between December 2014 and November 2016. Risk-adjusted PI incidence rates over eight study quarters. Incidence density over the study period was 1.33 pressure injuries per 1000 resident days (95% confidence interval (CI) = 1.29-1.37). Funnel plots were used to identify variation among facilities. On average, 14% of facilities had risk-adjusted PI rates that were higher than expected in each quarter (above 95% funnel plot control limits). Ten percent of facilities had persistently high rates in any three or more consecutive quarters (n = 6). The variation between facilities was only partly explained by resident characteristics in multilevel regression models. Residents were more likely to have higher-pressure injury rates in facilities in regional areas compared with major city areas (adjusted incidence rate ratio = 1.25, 95% CI = 1.04-1.51), and facilities with persistently high rates were more likely to be located in areas with low socioeconomic status (P = 0.038). There is considerable variation among facilities in PI incidence. This study demonstrates the potential of routinely-collected care management data to monitor PI incidence and to identify facilities that may benefit from targeted intervention.
Acute impact of drinking coffee on the cerebral and systemic vasculature.
Washio, Takuro; Sasaki, Hiroyuki; Ogoh, Shigehiko
2017-05-01
Previous studies have suggested that the risk of ischemic stroke increases immediately after drinking coffee. Indeed, drinking coffee, that is, caffeine, acutely increases arterial stiffness as well as blood pressure and peripheral vascular resistance. On the other hand, it has been reported that arterial stiffening is associated with elevation in the pulsatility index (PI) of cerebral blood flow (CBF), which increases the risk of brain disease. However, the effect of drinking coffee on the PI of the CBF and its interaction with arterial stiffness remain unknown. Against this background, we hypothesized that an acute increase in arterial stiffness induced by drinking coffee augments cerebral pulsatile stress. To test this hypothesis, in 10 healthy young men we examined the effects of drinking coffee on the PI of middle cerebral artery blood velocity (MCAv) and brachial-ankle pulse wave velocity (baPWV) as indices of cerebral pulsatile stress and arterial stiffness, respectively. Mean arterial blood pressure and baPWV were higher ( P < 0.01 and P = 0.02), whereas mean MCA V and mean cerebrovascular conductance index were lower upon drinking coffee ( P = 0.02 and P < 0.01) compared with a placebo (decaffeinated coffee). However, there was no difference in the PI of MCAv between drinking coffee and the placebo condition. These findings suggest that drinking coffee does not increase cerebral pulsatile stress acutely despite an elevation in arterial stiffness in the systemic circulation. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.
Saturation of subjective reward magnitude as a function of current and pulse frequency.
Simmons, J M; Gallistel, C R
1994-02-01
In rats with electrodes in the medial forebrain bundle, the upper portion of the function relating the experienced magnitude of the reward to pulse frequency was determined at currents ranging from 100 to 1,000 microA. The pulse frequency required to produce an asymptotic level of reward was inversely proportional to current except at the lowest currents and highest pulse frequencies. At a given current, the subjective reward magnitude functions decelerated to an asymptote over an interval in which the pulse frequency doubled or tripled. The asymptotic level of reward was approximately constant for currents between 200 and 1,000 microA but declined substantially at currents at or below 100 microA and pulse frequencies at or above 250 to 400 pulses per second. The results are consistent with the hypothesis that the magnitude of the experienced reward depends only on the number of action potentials generated by the train of pulses in the bundle of reward-relevant axons.
Ultra-wideband radar motion sensor
McEwan, Thomas E.
1994-01-01
A motion sensor is based on ultra-wideband (UWB) radar. UWB radar range is determined by a pulse-echo interval. For motion detection, the sensors operate by staring at a fixed range and then sensing any change in the averaged radar reflectivity at that range. A sampling gate is opened at a fixed delay after the emission of a transmit pulse. The resultant sampling gate output is averaged over repeated pulses. Changes in the averaged sampling gate output represent changes in the radar reflectivity at a particular range, and thus motion.
Ultra-wideband radar motion sensor
McEwan, T.E.
1994-11-01
A motion sensor is based on ultra-wideband (UWB) radar. UWB radar range is determined by a pulse-echo interval. For motion detection, the sensors operate by staring at a fixed range and then sensing any change in the averaged radar reflectivity at that range. A sampling gate is opened at a fixed delay after the emission of a transmit pulse. The resultant sampling gate output is averaged over repeated pulses. Changes in the averaged sampling gate output represent changes in the radar reflectivity at a particular range, and thus motion. 15 figs.
McCrea, Cindy E; Skulas-Ray, Ann C; Chow, Mosuk; West, Sheila G
2012-02-01
Endothelial dysfunction is an important outcome for assessing vascular health in intervention studies. However, reliability of the standard non-invasive method (flow-mediated dilation) is a significant challenge for clinical applications and multicenter trials. We evaluated the repeatability of pulse amplitude tonometry (PAT) to measure change in pulse wave amplitude during reactive hyperemia (Itamar Medical Ltd, Caesarea, Israel). Twenty healthy adults completed two PAT tests (mean interval = 19.5 days) under standardized conditions. PAT-derived measures of endothelial function (reactive hyperemia index, RHI) and arterial stiffness (augmentation index, AI) showed strong repeatability (intra-class correlations = 0.74 and 0.83, respectively). To guide future research, we also analyzed sample size requirements for a range of effect sizes. A crossover design powered at 0.90 requires 28 participants to detect a 15% change in RHI. Our study is the first to show that PAT measurements are repeatable in adults over an interval greater than 1 week.
A fatigue monitoring system based on time-domain and frequency-domain analysis of pulse data
NASA Astrophysics Data System (ADS)
Shen, Jiaai
2018-04-01
Fatigue is almost a problem that everyone would face, and a psychosis that everyone hates. If we can test people's fatigue condition and remind them of the tiredness, dangers in life, for instance, traffic accidents and sudden death will be effectively reduced, people's fatigued operations will be avoided. And people can be assisted to have access to their own and others' physical condition in time to alternate work with rest. The article develops a wearable bracelet based on FFT Pulse Frequency Spectrum Analysis and IBI's standard deviation and range calculation, according to people's heart rate (BPM) and inter-beat interval (IBI) while being tired and conscious. The hardware part is based on Arduino, pulse rate sensor, and Bluetooth module, and the software part is relied on network micro database and APP. By doing sample experiment to get more accurate standard value to judge tiredness, we prove that we can judge people's fatigue condition based on heart rate (BPM) and inter-beat interval (IBI).
Kauppi, Jukka-Pekka; Martikainen, Kalle; Ruotsalainen, Ulla
2010-12-01
The central purpose of passive signal intercept receivers is to perform automatic categorization of unknown radar signals. Currently, there is an urgent need to develop intelligent classification algorithms for these devices due to emerging complexity of radar waveforms. Especially multifunction radars (MFRs) capable of performing several simultaneous tasks by utilizing complex, dynamically varying scheduled waveforms are a major challenge for automatic pattern classification systems. To assist recognition of complex radar emissions in modern intercept receivers, we have developed a novel method to recognize dynamically varying pulse repetition interval (PRI) modulation patterns emitted by MFRs. We use robust feature extraction and classifier design techniques to assist recognition in unpredictable real-world signal environments. We classify received pulse trains hierarchically which allows unambiguous detection of the subpatterns using a sliding window. Accuracy, robustness and reliability of the technique are demonstrated with extensive simulations using both static and dynamically varying PRI modulation patterns. Copyright © 2010 Elsevier Ltd. All rights reserved.
Interval Timing Accuracy and Scalar Timing in C57BL/6 Mice
Buhusi, Catalin V.; Aziz, Dyana; Winslow, David; Carter, Rickey E.; Swearingen, Joshua E.; Buhusi, Mona C.
2010-01-01
In many species, interval timing behavior is accurate—appropriate estimated durations—and scalar—errors vary linearly with estimated durations. While accuracy has been previously examined, scalar timing has not been yet clearly demonstrated in house mice (Mus musculus), raising concerns about mouse models of human disease. We estimated timing accuracy and precision in C57BL/6 mice, the most used background strain for genetic models of human disease, in a peak-interval procedure with multiple intervals. Both when timing two intervals (Experiment 1) or three intervals (Experiment 2), C57BL/6 mice demonstrated varying degrees of timing accuracy. Importantly, both at individual and group level, their precision varied linearly with the subjective estimated duration. Further evidence for scalar timing was obtained using an intraclass correlation statistic. This is the first report of consistent, reliable scalar timing in a sizable sample of house mice, thus validating the PI procedure as a valuable technique, the intraclass correlation statistic as a powerful test of the scalar property, and the C57BL/6 strain as a suitable background for behavioral investigations of genetically engineered mice modeling disorders of interval timing. PMID:19824777
Probe Measurements of Parameters of Streamers of Nanosecond Frequency Crown Discharge
NASA Astrophysics Data System (ADS)
Ponizovskiy, A. Z.; Gosteev, S. G.
2017-12-01
Investigations of the parameters of single streamers of nanosecond frequency corona discharge, creating a voluminous low-temperature plasma in extended coaxial electrode systems, are performed. Measurements of the parameters of streamers were made by an isolated probe situated on the outer grounded electrode. Streamers were generated under the action of voltage pulses with a front of 50-300 ns, duration of 100-600 ns, and amplitude up to 100 kV at the frequency of 50-1000 Hz. The pulse voltage, the total current of the corona, current per probe, and glow in the discharge gap were recorded in the experiments. It was established that, at these parameters of pulse voltage, streamers propagate at an average strength of the electric field of 4-10 kV/cm. Increasing the pulse amplitude leads to an increase in the number of streamers hitting the probe, an increase in the average charge of the head of a streamer, and, as a consequence, an increase in the total streamer current and the energy introduced into the gas. In the intervals up to 3 cm, streamer breakdown at an average field strength of 5-10 kV/cm is possible. In longer intervals, during the buildup of voltage after generation of the main pulse, RF breakdown is observed at E av ≈ 4 kV/cm.
NASA Astrophysics Data System (ADS)
Christenson, M.; Stemmley, S.; Jung, S.; Mettler, J.; Sang, X.; Martin, D.; Kalathiparambil, K.; Ruzic, D. N.
2017-08-01
The ThermoElectric-driven Liquid-metal plasma-facing Structures (TELS) experiment at the University of Illinois is a gas-puff driven, theta-pinch plasma source that is used as a test stand for off-normal plasma events incident on materials in the edge and divertor regions of a tokamak. The ion temperatures and resulting energy distributions are crucial for understanding how well a TELS pulse can simulate an extreme event in a larger, magnetic confinement device. A retarding field energy analyzer (RFEA) has been constructed for use with such a transient plasma due to its inexpensive and robust nature. The innovation surrounding the use of a control analyzer in conjunction with an actively sampling analyzer is presented and the conditions of RFEA operation are discussed, with results presented demonstrating successful performance under extreme conditions. Such extreme conditions are defined by heat fluxes on the order of 0.8 GW m-2 and on time scales of nearly 200 μs. Measurements from the RFEA indicate two primary features for a typical TELS discharge, following closely with the pre-ionizing coaxial gun discharge characteristics. For the case using the pre-ionization pulse (PiP) and the theta pinch, the measured ion signal showed an ion temperature of 23.3 ± 6.6 eV for the first peak and 17.6 ± 1.9 eV for the second peak. For the case using only the PiP, the measured signal showed an ion temperature of 7.9 ± 1.1 eV for the first peak and 6.6 ± 0.8 eV for the second peak. These differences illustrate the effectiveness of the theta pinch for imparting energy on the ions. This information also highlights the importance of TELS as being one of the few linear pulsed plasma sources whereby moderately energetic ions will strike targets without the need for sample biasing.
Christenson, M; Stemmley, S; Jung, S; Mettler, J; Sang, X; Martin, D; Kalathiparambil, K; Ruzic, D N
2017-08-01
The ThermoElectric-driven Liquid-metal plasma-facing Structures (TELS) experiment at the University of Illinois is a gas-puff driven, theta-pinch plasma source that is used as a test stand for off-normal plasma events incident on materials in the edge and divertor regions of a tokamak. The ion temperatures and resulting energy distributions are crucial for understanding how well a TELS pulse can simulate an extreme event in a larger, magnetic confinement device. A retarding field energy analyzer (RFEA) has been constructed for use with such a transient plasma due to its inexpensive and robust nature. The innovation surrounding the use of a control analyzer in conjunction with an actively sampling analyzer is presented and the conditions of RFEA operation are discussed, with results presented demonstrating successful performance under extreme conditions. Such extreme conditions are defined by heat fluxes on the order of 0.8 GW m -2 and on time scales of nearly 200 μs. Measurements from the RFEA indicate two primary features for a typical TELS discharge, following closely with the pre-ionizing coaxial gun discharge characteristics. For the case using the pre-ionization pulse (PiP) and the theta pinch, the measured ion signal showed an ion temperature of 23.3 ± 6.6 eV for the first peak and 17.6 ± 1.9 eV for the second peak. For the case using only the PiP, the measured signal showed an ion temperature of 7.9 ± 1.1 eV for the first peak and 6.6 ± 0.8 eV for the second peak. These differences illustrate the effectiveness of the theta pinch for imparting energy on the ions. This information also highlights the importance of TELS as being one of the few linear pulsed plasma sources whereby moderately energetic ions will strike targets without the need for sample biasing.
NASA Astrophysics Data System (ADS)
Koblents, B.; Belanger, M.; Woods, D.; McLane, P. J.
While conventional analog modems employ some kind of clock wave regenerator circuit for synchronous timing recovery, in sampled modem receivers the timing is recovered asynchronously to the incoming data stream, with no adjustment being made to the input sampling rate. All timing corrections are accomplished by digital operations on the sampled data stream, and timing recovery is asynchronous with the uncontrolled, input A/D system. A good timing error measurement algorithm is a zero crossing tracker proposed by Gardner. Digital, speech rate (2400 - 4800 bps) M-PSK modem receivers employing Gardner's zero crossing tracker were implemented and tested and found to achieve BER performance very close to theoretical values on the AWGN channel. Nyguist pulse shaped modem systems with excess bandwidth factors ranging from 100 to 60 percent were considered. We can show that for any symmetric M-PSK signal set Gardner's NDA algorithm is free of pattern jitter for any carrier phase offset for rectangular pulses and for Nyquist pulses having 100 percent excess bandwidth. Also, the Nyquist pulse shaped system is studied on the mobile satellite channel, where Doppler shifts and multipath fading degrade the pi/4-DQPSK signal. Two simple modifications to Gardner's zero crossing tracker enable it to remain useful in the presence of multipath fading.
NASA Technical Reports Server (NTRS)
Koblents, B.; Belanger, M.; Woods, D.; Mclane, P. J.
1993-01-01
While conventional analog modems employ some kind of clock wave regenerator circuit for synchronous timing recovery, in sampled modem receivers the timing is recovered asynchronously to the incoming data stream, with no adjustment being made to the input sampling rate. All timing corrections are accomplished by digital operations on the sampled data stream, and timing recovery is asynchronous with the uncontrolled, input A/D system. A good timing error measurement algorithm is a zero crossing tracker proposed by Gardner. Digital, speech rate (2400 - 4800 bps) M-PSK modem receivers employing Gardner's zero crossing tracker were implemented and tested and found to achieve BER performance very close to theoretical values on the AWGN channel. Nyguist pulse shaped modem systems with excess bandwidth factors ranging from 100 to 60 percent were considered. We can show that for any symmetric M-PSK signal set Gardner's NDA algorithm is free of pattern jitter for any carrier phase offset for rectangular pulses and for Nyquist pulses having 100 percent excess bandwidth. Also, the Nyquist pulse shaped system is studied on the mobile satellite channel, where Doppler shifts and multipath fading degrade the pi/4-DQPSK signal. Two simple modifications to Gardner's zero crossing tracker enable it to remain useful in the presence of multipath fading.
A robust adaptive load frequency control for micro-grids.
Khooban, Mohammad-Hassan; Niknam, Taher; Blaabjerg, Frede; Davari, Pooya; Dragicevic, Tomislav
2016-11-01
The goal of this study is to introduce a novel robust load frequency control (LFC) strategy for micro-grid(s) (MG(s)) in islanded mode operation. Admittedly, power generators in MG(s) cannot supply steady electric power output and sometimes cause unbalance between supply and demand. Battery energy storage system (BESS) is one of the effective solutions to these problems. Due to the high cost of the BESS, a new idea of Vehicle-to-Grid (V2G) is that a battery of Electric-Vehicle (EV) can be applied as a tantamount large-scale BESS in MG(s). As a result, a new robust control strategy for an islanded micro-grid (MG) is introduced that can consider electric vehicles׳ (EV(s)) effect. Moreover, in this paper, a new combination of the General Type II Fuzzy Logic Sets (GT2FLS) and the Modified Harmony Search Algorithm (MHSA) technique is applied for adaptive tuning of proportional-integral (PI) controller. Implementing General Type II Fuzzy Systems is computationally expensive. However, using a recently introduced α-plane representation, GT2FLS can be seen as a composition of several Interval Type II Fuzzy Logic Systems (IT2FLS) with a corresponding level of α for each. Real-data from an offshore wind farm in Sweden and solar radiation data in Aberdeen (United Kingdom) was used in order to examine the performance of the proposed novel controller. A comparison is made between the achieved results of Optimal Fuzzy-PI (OFPI) controller and those of Optimal Interval Type II Fuzzy-PI (IT2FPI) controller, which are of most recent advances in the area at hand. The Simulation results prove the successfulness and effectiveness of the proposed controller. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.
Hall, Isaac E.; Bhangoo, Ronik S.; Reese, Peter P.; Doshi, Mona D.; Weng, Francis L.; Hong, Kwangik; Lin, Haiqun; Han, Gang; Hasz, Rick D.; Goldstein, Michael J.; Schröppel, Bernd; Parikh, Chirag R.
2014-01-01
Accurate and reliable assessment tools are needed in transplantation. The objective of this prospective, multicenter study was to determine the associations of the alpha and pi iso-enzymes of glutathione S-transferase (GST), measured from perfusate solution at the start and end (base and post) of kidney allograft machine perfusion, with subsequent delayed graft function (DGF). We also compared GST iso-enzyme perfusate levels from discarded versus transplanted kidneys. A total of 428 kidneys were linked to outcomes as recorded by the United Network of Organ Sharing. DGF, defined as any dialysis in the first week of transplant, occurred in 141 recipients (32%). Alpha and pi-GST levels significantly increased during machine perfusion. The adjusted relative risks (95% confidence interval) of DGF with each log-unit increase in base and post pi-GST were 1.14 (1.0-1.28) and 1.33 (1.02-1.72), respectively. Alpha-GST was not independently associated with DGF. There were no significant differences in GST values between discarded and transplanted kidneys, though renal resistance was significantly higher in discarded kidneys. We found pi-GST at the end of machine perfusion to be independently associated with DGF. Further studies should elucidate the utility of GST for identifying injured kidneys with regard to organ allocation, discard and recipient management decisions. PMID:24612768
Isoelectric focusing of dansylated amino acids in immobilized pH gradients
NASA Technical Reports Server (NTRS)
Bianchi-Bosisio, Adriana; Righetti, Pier Giorgio; Egen, Ned B.; Bier, Milan
1986-01-01
The 21 free amino acids commonly encountered in proteins have been transformed into 'carrier ampholyte' species by reacting their primary amino groups with dansyl chloride. These derivatives can thus be focused in an immobilized pH gradient covering the pH interval 3.1 to 4.1, except for arginine, which still retains a pI of 8.8. Due to their inherent fluorescence, the dansyl derivatives are revealed in UV light, with a sensitivity of the order of 2-4 ng/sq mm. All nearest neighbors are separated except for the following couples: Asn-Gln, Gly-Thr, Val-Ile and Cys-Cys2, with a resolving power, in a Delta(pI) scale, of the order of 0.0018 pH units. Except for a few cases (notably the aromatic amino acids), the order of pI values is well correlated with the pK values of carboxyl groups, suggesting that the latter are not altered by dansylation. From the set of pK(COOH)-pI values of the different amino acids, the pK of the tertiary amino group in the dansyl label has been calculated to be 5.11 + or - 0.06. Knowing the pK of the amino-dansyl and the pI of the excess, free dansyl label (pI = 3.34), a pK of 1.57 is derived for its sulfonic acid group.
Enander, I; Ahlstedt, S; Nygren, H
1984-01-01
Mice (BALB/c) exposed to picryl chloride (PiCl) on their shaved abdomen and untreated animals were after 7 days exposed to daily aerosolized trinitrophenylated dog serum albumin (TNP-DSA). Mice exposed to PiCl tended to respond earlier and more strongly with both delayed hypersensitivity (DH) and IgG antibodies in serum and bronchial washings than did mice exposed to aerosol only. Picryl chloride sensitization resulted in spontaneously proliferating axillary lymph node cells, which could not be further stimulated with antigen or mitogen. Histological examination of lung tissue of aerosol-sensitized animals revealed an increase in mononuclear cells and mast cells around bronchioli and mucous cells, particularly in those animals exposed for prolonged periods and sensitized with PiCl prior to aerosol. Sensitization of mice with aerosolized TNP-DSA administrated in two 2- and 1-week periods with a 4-week interval responded with DH and IgG antibody in a dose dependent fashion irrespective of presensitization with PiCl. In bronchial washings IgG antibodies were found particularly after two 2-week periods of exposure. The cells taken from the axillary or brachial lymph nodes showed spontaneous proliferation. Culture of the cells to achieve mast cell maturation resulted in no or very low numbers of mast cells in the lymph nodes. PMID:6706375
Nelson, Anita; Parke, Susanne; Makalova, Dagmar; Serrani, Marco; Palacios, Santiago; Mellinger, Uwe
2013-08-01
To summarise all clinical data on the contraceptive efficacy and bleeding profile associated with an oestradiol valerate (E2V) and dienogest (DNG) [E2V/DNG] combined oral contraceptive (COC) derived from Phase III trials. Pooled analysis of three large-scale multicentre trials conducted in healthy women who received oral E2V/DNG for 7 to 28 cycles (28-day cycles). A total of 2266 women were included in this analysis. Overall, 19 pregnancies occurred over 13 cycles during 880,950 days of relevant exposure (Pearl Index [PI] of 0.79; upper limit of the two-sided 95% confidence interval [CI]: 1.23). Ten pregnancies attributed to method failure came about during 871,091 days of relevant exposure (adjusted PI of 0.42; upper limit of the two-sided 95% CI: 0.77). In women aged 18 to 35 years (n = 1687), the corresponding PI and adjusted PI were 1.01 (upper limit of the two-sided 95% CI: 1.59) and 0.51 (upper limit of the two-sided 95% CI: 0.97), respectively. In the first 13 cycles of treatment, 76 to 81% of women experienced scheduled withdrawal bleeding, and 13 to 23% experienced intracyclic bleeding. E2V/DNG provides reliable contraceptive efficacy in women aged 18 to 50 years.
NASA Astrophysics Data System (ADS)
Buckman, S. M.; Ius, D.
1996-02-01
This paper reports on the development of a digital coincidence-counting system which comprises a custom-built data acquisition card and associated PC software. The system has been designed to digitise the pulse-trains from two radiation detectors at a rate of 20 MSamples/s with 12-bit resolution. Through hardware compression of the data, the system can continuously record both individual pulse-shapes and the time intervals between pulses. Software-based circuits are used to process the stored pulse trains. These circuits are constructed simply by linking together icons representing various components such as coincidence mixers, time delays, single-channel analysers, deadtimes and scalers. This system enables a pair of pulse trains to be processed repeatedly using any number of different methods. Some preliminary results are presented in order to demonstrate the versatility and efficiency of this new method.
Chen, Xiaodong; Chen, Minglong; Wang, Yingying; Yang, Bing; Ju, Weizhu; Zhang, Fengxiang; Cao, Kejiang
2016-11-01
We sought to investigate variation of atrial electromechanical interval after catheter ablation procedure in patients with persistent atrial fibrillation using pulse Doppler (PW) and pulse tissue Doppler imaging (PW-TDI). A total of 25 consecutive in-patients with persistent atrial fibrillation, who restored sinus rhythm after ablation procedure, were recruited in our cardiac center. Echocardiography was performed on each patient at 2 hours, 1 day, 5 days, 1 month and 3 months after the ablation therapy, and atrial electromechanical delay was measured simultaneously by PW and PW-TDI. There was no significant difference between PW and TDI in measuring atrial electromechanical delay. However, at postoperative 2 hours, peak A detection rates were mathematically but nonsignificantly greater by PW-TDI than by PW. Second, there was a significant decreasing trend in atrial electromechanical interval from postoperative 2 hours to 3 months, but only postoperative 2-hour atrial electromechanical interval was significantly greater than atrial electromechanical interval at other time. Lastly, patients without postoperative 2-hour atrial electromechanical interval had a significantly longer duration of atrial fibrillation as compared to those with postoperative 2-hour atrial electromechanical interval, by the PW or by PW-TDI, respectively. In patients with persistent atrial fibrillation, atrial electromechanical interval may decrease significantly within the first 24 hours after ablation but remain consistent later, and was significantly related to patients' duration of atrial fibrillation. Atrial electromechanical interval, as a potential predicted factor, is recommended to be measured by either PW or TDI after 24 hours, when patients had recovered sinus rhythm by radiofrequency ablation. © 2016 by the Journal of Biomedical Research. All rights reserved.
High resolution in situ ultrasonic corrosion monitor
Grossman, R.J.
1984-01-10
An ultrasonic corrosion monitor is provided which produces an in situ measurement of the amount of corrosion of a monitoring zone or zones of an elongate probe placed in the corrosive environment. A monitoring zone is preferably formed between the end of the probe and the junction of the zone with a lead-in portion of the probe. Ultrasonic pulses are applied to the probe and a determination made of the time interval between pulses reflected from the end of the probe and the junction referred to, both when the probe is uncorroded and while it is corroding. Corresponding electrical signals are produced and a value for the normalized transit time delay derived from these time interval measurements is used to calculate the amount of corrosion.
High resolution in situ ultrasonic corrosion monitor
Grossman, Robert J.
1985-01-01
An ultrasonic corrosion monitor is provided which produces an in situ measurement of the amount of corrosion of a monitoring zone or zones of an elongate probe placed in the corrosive environment. A monitoring zone is preferably formed between the end of the probe and the junction of the zone with a lead-in portion of the probe. Ultrasonic pulses are applied to the probe and a determination made of the time interval between pulses reflected from the end of the probe and the junction referred to, both when the probe is uncorroded and while it is corroding. Corresponding electrical signals are produced and a value for the normalized transit time delay derived from these time interval measurements is used to calculate the amount of corrosion.
Analysis of the statistic al properties of pulses in atmospheric corona discharge
NASA Astrophysics Data System (ADS)
Aubrecht, L.; Koller, J.; Plocek, J.; Stanék, Z.
2000-03-01
The properties of the negative corona current pulses in a single point-to-plane configuration have been extensively studied by many investigators. The amplitude and the interval of these pulses are not generally constant and depend on many variables. The repetition rate and the amplitude of the pulses fluctuate in time. Since these fluctuations are subject to a certain probability distribution, the statistical processing was used for the analysis of the pulse fluctuations. The behavior of the pulses has been also investigated in a multipoint geometry configuration. The dependence of the behavior of the corona pulses on the gap lengths, the material, the shape of the point electrode, the number and separation of electrodes (in the multiple-point mode) has been investigated, too. No detailed study has been carried out up to now for this case. The attention has been devoted also to the study of the pulses on the points of live materials (needles of coniferous trees). This contribution describes recent studies of the statistical properties of the pulses for various conditions.
Coherence rephasing combined with spin-wave storage using chirped control pulses
NASA Astrophysics Data System (ADS)
Demeter, Gabor
2014-06-01
Photon-echo based optical quantum memory schemes often employ intermediate steps to transform optical coherences to spin coherences for longer storage times. We analyze a scheme that uses three identical chirped control pulses for coherence rephasing in an inhomogeneously broadened ensemble of three-level Λ systems. The pulses induce a cyclic permutation of the atomic populations in the adiabatic regime. Optical coherences created by a signal pulse are stored as spin coherences at an intermediate time interval, and are rephased for echo emission when the ensemble is returned to the initial state. Echo emission during a possible partial rephasing when the medium is inverted can be suppressed with an appropriate choice of control pulse wave vectors. We demonstrate that the scheme works in an optically dense ensemble, despite control pulse distortions during propagation. It integrates conveniently the spin-wave storage step into memory schemes based on a second rephasing of the atomic coherences.
Moreno-Arias, G A; Ferrando, J
2001-01-01
Few reports about melanocytic lesions treatment by means of noncoherent-intense-pulsed light (NCIPL) have been published. Here we evaluate the clinical results of a relapsing hairy intradermal melanocytic nevus treated with a noncoherent-intense-pulsed light source. A facial repigmented hairy intradermal melanocytic nevus that relapsed after shave excision, received four treatment sessions of a noncoherent-intense-pulsed light source (EpiLight, ESC Medical Systems Ltd, Israel) with the following parameters: 755 nm, a fluence energy of 40-42.5 J/cm(2), triple mode, a pulse width of 3.8 ms, and a delay of 20 ms, at 4-week intervals. Complete pigment clearance and hair removal was obtained. We have neither observed repigmentation nor hair regrowth after a 6 month-follow-up. No side effects were documented. Noncoherent-intense-pulse light is an effective treatment for hairy-pigmented melanocytic nevus. Copyright 2001 Wiley-Liss, Inc.
Yang, Limei; Sostaric, Joe Z; Rathman, James F; Kuppusamy, Periannan; Weavers, Linda K
2007-02-15
Sonolysis of argon-saturated aqueous solutions of the nonvolatile surfactants sodium dodecyl sulfate (SDS) and sodium 1-pentanesulfonate (SPSo) was investigated at three ultrasonic frequencies under both continuous wave (CW) and pulsed ultrasound. Secondary carbon-centered radicals were detected by spin trapping using 3,5-dibromo-4-nitrosobenzenesulfonic acid (DBNBS) and electron paramagnetic resonance (EPR) spectroscopy. Following sonolysis, -*CH- radicals were observed for both surfactants under both sonication modes. Under CW at 354 kHz, the maximum plateau -*CH- radical yield was higher for SPSo than for SDS, indicating that SDS, which is more surface active under equilibrium conditions, accumulates at the gas/solution interface of cavitation bubbles to a lesser degree, compared with the less surface active surfactant, SPSo. However, after sonolysis (354 kHz) under pulsed ultrasound with a pulse length of 100 ms and an interval of 500 ms, the -*CH- radical yield at the plateau concentrations was higher for SDS than for SPSo due to increased amounts of SDS accumulation on the bubble surfaces. In contrast to the findings following sonolysis at 354 kHz, sonolysis of aqueous surfactant solutions at 620 kHz and 803 kHz showed a higher -*CH- radical yield for SDS compared with SPSo under CW but lower -*CH- radical yield with increasing pulsing interval, indicating a frequency dependence on accumulation. Results indicate that pulsing the ultrasonic wave has a significant effect on the relative adsorption ability of n-alkyl surfactants at the gas/solution surface of cavitation bubbles.
Baseband pulse shaping techniques for nonlinearly amplified pi/4-QPSK and QAM systems
NASA Technical Reports Server (NTRS)
Feher, Kamilo
1991-01-01
A new generation of multi-stage pi/4-shifted QPSK and of superposed quadrature-amplitude-modulated (SQAM) modulators-coherent demodulators (modems) and of continuous phase modulated (CPM)-gaussian premodulation filtered minimum-shift-keying (MGMSK) systems is proposed and studied. These modems will lead to bandwidth and power efficient satellite communications systems designs. As an illustrative application, a baseband processing technique pi/4-controlled transition PSK (pi/4-CTPSK) is described. To develop a cost and power efficient design strategy, we assume that nonlinear, fully saturated high power amplifiers (HPA) are utilized in the satellite earth station transmitter and in the satellite transponder. Modem structures which could lead to application specific integrated circuit (ASIC) satellite on-board processing universal modem applications are also considered. Multistate GMSK (i.e., MGMSK) signal generation methods by means of two or more RF combined nonlinearly amplified SQAM modems and by one multistate (in-phase and quadrature-baseband premodulation filtered-superposed) SQAM architecture and one RF nonlinear amplifier are studied. During the SQAM modem development phase we investigate the potential system advantages of the pi/4-shifted logic. The bandwidth efficiency of the proposed multistate GMSK and baseband filtered PAM-FM modulator (a new class in the CPM family) will be significantly higher than that of conventional G-MSK systems. To optimize the practical P(sub e) = f((E sub b)/(N sub o)) performance we consider improved coherent demodulation MGMSK structures such as deviated-frequency locking coherent demodulators. For relative low bit rate SATCOM applications, e.g., bit rates less than 300 kb/s, phase noise tracking cancellation (for fixed site earth station) and phase noise cancellation as well as Doppler compensation (for satellite to mobile earth station) applications may be required. We study digital channel sounding methods which could cancel the phase noise-caused degradations of CPM and GMSK modems.
2015-06-01
CP AP because of claustrophobia, noise, nose bleeds, dermatitis and nasal bridge sores. In many cases, these effects are due to incorrect pressure...checked for contact data in case a subject must be contacted due to scheduling problems, or some new information is learned that a subject needs to know...Subject initiated contacts via phone or email to the PI with respect to adverse events, side effects or questions will be recorded on an electronic log
Single photon detection and timing in the Lunar Laser Ranging Experiment.
NASA Technical Reports Server (NTRS)
Poultney, S. K.
1972-01-01
The goals of the Lunar Laser Ranging Experiment lead to the need for the measurement of a 2.5 sec time interval to an accuracy of a nanosecond or better. The systems analysis which included practical retroreflector arrays, available laser systems, and large telescopes led to the necessity of single photon detection. Operation under all background illumination conditions required auxiliary range gates and extremely narrow spectral and spatial filters in addition to the effective gate provided by the time resolution. Nanosecond timing precision at relatively high detection efficiency was obtained using the RCA C31000F photomultiplier and Ortec 270 constant fraction of pulse-height timing discriminator. The timing accuracy over the 2.5 sec interval was obtained using a digital interval with analog vernier ends. Both precision and accuracy are currently checked internally using a triggerable, nanosecond light pulser. Future measurements using sub-nanosecond laser pulses will be limited by the time resolution of single photon detectors.
Gattinger, Norbert; Moessnang, Georg; Gleich, Bernhard
2012-07-01
Transcranial magnetic stimulation (TMS) is able to noninvasively excite neuronal populations due to brief magnetic field pulses. The efficiency and the characteristics of stimulation pulse shapes influence the physiological effect of TMS. However, commercial devices allow only a minimum of control of different pulse shapes. Basically, just sinusoidal and monophasic pulse shapes with fixed pulse widths are available. Only few research groups work on TMS devices with controllable pulse parameters such as pulse shape or pulse width. We describe a novel TMS device with a full-bridge circuit topology incorporating four insulated-gate bipolar transistor (IGBT) modules and one energy storage capacitor to generate arbitrary waveforms. This flexible TMS (flexTMS ) device can generate magnetic pulses which can be adjusted with respect to pulse width, polarity, and intensity. Furthermore, the equipment allows us to set paired pulses with a variable interstimulus interval (ISI) from 0 to 20 ms with a step size of 10 μs. All user-defined pulses can be applied continually with repetition rates up to 30 pulses per second (pps) or, respectively, up to 100 pps in theta burst mode. Offering this variety of flexibility, flexTMS will allow the enhancement of existing TMS paradigms and novel research applications.
El Allaki, Farouk; Harrington, Noel; Howden, Krista
2016-11-01
The objectives of this study were (1) to estimate the annual sensitivity of Canada's bTB surveillance system and its three system components (slaughter surveillance, export testing and disease investigation) using a scenario tree modelling approach, and (2) to identify key model parameters that influence the estimates of the surveillance system sensitivity (SSSe). To achieve these objectives, we designed stochastic scenario tree models for three surveillance system components included in the analysis. Demographic data, slaughter data, export testing data, and disease investigation data from 2009 to 2013 were extracted for input into the scenario trees. Sensitivity analysis was conducted to identify key influential parameters on SSSe estimates. The median annual SSSe estimates generated from the study were very high, ranging from 0.95 (95% probability interval [PI]: 0.88-0.98) to 0.97 (95% PI: 0.93-0.99). Median annual sensitivity estimates for the slaughter surveillance component ranged from 0.95 (95% PI: 0.88-0.98) to 0.97 (95% PI: 0.93-0.99). This shows that slaughter surveillance to be the major contributor to overall surveillance system sensitivity with a high probability to detect M. bovis infection if present at a prevalence of 0.00028% or greater during the study period. The export testing and disease investigation components had extremely low component sensitivity estimates-the maximum median sensitivity estimates were 0.02 (95% PI: 0.014-0.023) and 0.0061 (95% PI: 0.0056-0.0066) respectively. The three most influential input parameters on the model's output (SSSe) were the probability of a granuloma being detected at slaughter inspection, the probability of a granuloma being present in older animals (≥12 months of age), and the probability of a granuloma sample being submitted to the laboratory. Additional studies are required to reduce the levels of uncertainty and variability associated with these three parameters influencing the surveillance system sensitivity. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.
Juszczak, K; Kaszuba-Zwoinska, J; Thor, P J
2012-08-01
The evidence of electromagnetic therapy (EMT) efficacy in stress and/or urge urinary incontinence, as well as in detrusor overactivity is generally lacking in the literature. The potential EMT action of neuromuscular tissue depolarization has been described. Because there is no data on the influence of pulsating electromagnetic fields (PEMF) on the urothelium, we evaluated the effect of PEMF stimulation on rat urothelial cultured cells (RUCC). In our study 15 Wistar rats were used for RUCC preparation. RUCC were exposed to PEMF (50 Hz, 45±5 mT) three times for 4 hours each with 24-hour intervals. The unexposed RUCC was in the same incubator, but in a distance of 35 cm from the PEMF generator. Annexin V-APC (AnV+) labelled was used to determine the percentage of apoptotic cells and propidium iodide (PI+), as standard flow cytometric viability probe to distinguish necrotic cells from viable ones. The results are presented in percentage values. The flow cytometric analysis was carried out on a FACS calibur flow cytometer using Cell-Quest software. In PEMF-unstimulated RUCC, the percentage of AnV+, PI+, and AnV+PI+ positive cells were 1.24±0.34%, 11.03±1.55%, and 12.43±1.96%, respectively. The percentages of AnV+, PI+, and AnV+PI+ positive cells obtained after PEMF stimulation were 1.45±0.16% (p=0.027), 7.03±1.76% (p<0.001), and 9.48±3.40% (p=0.003), respectively. The PEMF stimulation of RUCC induces apoptosis (increase of AnV+ cells) and inhibits necrosis (decrease of PI+ cells) of urothelial cells. This leads us to the conclusion that a low-frequency pulsating electromagnetic field stimulation induces apoptosis and diminishes necrosis of rat urothelial cells in culture.
Acharya, Amitabha; Ramanujam, Balaji; Mitra, Atanu; Rao, Chebrolu P
2010-07-27
This paper deals with the self-assembly of the 1:1 complex of two different amphiphiles, namely, a glucosyl-salicyl-imino conjugate (L) and phenylalanine (Phe), forming nanofibers over a period of time through pi...pi interactions. Significant enhancement observed in the fluorescence intensity of L at approximately 423 nm band and the significant decrease observed in the absorbance of the approximately 215 nm band are some characteristics of this self-assembly. Matrix-assisted laser desorption ionization/time of flight titration carried out at different time intervals supports the formation of higher aggregates. Atomic force microscopy (AFM), transmission electron microscopy, and scanning electron miscroscopy results showed the formation of nanofibers for the solutions of L with phenylalanine. In dynamic light scattering measurements, the distribution of the particles extends to a higher diameter range over time, indicating a slow kinetic process of assembly. Similar spectral and microscopy studies carried out with the control molecules support the role of the amino acid moiety over the simple -COOH moiety as well as the side chain phenyl moiety in association with the amino acid, in the formation of these fibers. All these observations support the presence of pi...pi interactions between the initially formed 1:1 complexes leading to the fiber formation. The aggregation of 1:1 complexes leading to fibers followed by the formation of bundles has been modeled by molecular mechanics studies. Thus the fiber formation with L is limited to phenylalanine and not to any other naturally occurring amino acid and hence a polymer composed of two different biocompatible amphiphiles. AFM studies carried out between the fiber forming mixture and proteins resulted in the observation that only BSA selectively adheres to the fiber among the three alpha-helical and two beta-sheet proteins studied and hence may be of use in some medical applications.
Statistical analysis of low-voltage EDS spectrum images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, I.M.
1998-03-01
The benefits of using low ({le}5 kV) operating voltages for energy-dispersive X-ray spectrometry (EDS) of bulk specimens have been explored only during the last few years. This paper couples low-voltage EDS with two other emerging areas of characterization: spectrum imaging of a computer chip manufactured by a major semiconductor company. Data acquisition was performed with a Philips XL30-FEG SEM operated at 4 kV and equipped with an Oxford super-ATW detector and XP3 pulse processor. The specimen was normal to the electron beam and the take-off angle for acquisition was 35{degree}. The microscope was operated with a 150 {micro}m diameter finalmore » aperture at spot size 3, which yielded an X-ray count rate of {approximately}2,000 s{sup {minus}1}. EDS spectrum images were acquired as Adobe Photoshop files with the 4pi plug-in module. (The spectrum images could also be stored as NIH Image files, but the raw data are automatically rescaled as maximum-contrast (0--255) 8-bit TIFF images -- even at 16-bit resolution -- which poses an inconvenience for quantitative analysis.) The 4pi plug-in module is designed for EDS X-ray mapping and allows simultaneous acquisition of maps from 48 elements plus an SEM image. The spectrum image was acquired by re-defining the energy intervals of 48 elements to form a series of contiguous 20 eV windows from 1.25 kV to 2.19 kV. A spectrum image of 450 x 344 pixels was acquired from the specimen with a sampling density of 50 nm/pixel and a dwell time of 0.25 live seconds per pixel, for a total acquisition time of {approximately}14 h. The binary data files were imported into Mathematica for analysis with software developed by the author at Oak Ridge National Laboratory. A 400 x 300 pixel section of the original image was analyzed. MSA required {approximately}185 Mbytes of memory and {approximately}18 h of CPU time on a 300 MHz Power Macintosh 9600.« less
NASA Technical Reports Server (NTRS)
Davidson, Frederic M.; Sun, Xiaoli; Field, Christopher T.
1995-01-01
Laser altimeters measure the time of flight of the laser pulses to determine the range of the target. The simplest altimeter receiver consists of a photodetector followed by a leading edge detector. A time interval unit (TIU) measures the time from the transmitted laser pulse to the leading edge of the received pulse as it crosses a preset threshold. However, the ranging error of this simple detection scheme depends on the received, pulse amplitude, pulse shape, and the threshold. In practice, the pulse shape and the amplitude are determined by the target target characteristics which has to be assumed unknown prior to the measurement. The ranging error can be improved if one also measures the pulse width and use the average of the leading and trailing edges (half pulse width) as the pulse arrival time. The ranging error becomes independent of the received pulse amplitude and the pulse width as long as the pulse shape is symmetric. The pulse width also gives the slope of the target. The ultimate detection scheme is to digitize the received waveform and calculate the centroid as the pulse arrival time. The centroid detection always gives unbiased measurement even for asymmetric pulses. In this report, we analyze the laser altimeter ranging errors for these three detection schemes using the Mars Orbital Laser Altimeter (MOLA) as an example.
Borges, Álvaro H; Lundh, Andreas; Tendal, Britta; Bartlett, John A; Clumeck, Nathan; Costagliola, Dominique; Daar, Eric S; Echeverría, Patrícia; Gisslén, Magnus; Huedo-Medina, Tania B; Hughes, Michael D; Huppler Hullsiek, Katherine; Khabo, Paul; Komati, Stephanus; Kumar, Princy; Lockman, Shahin; MacArthur, Rodger D; Maggiolo, Franco; Matteelli, Alberto; Miro, Jose M; Oka, Shinichi; Petoumenos, Kathy; Puls, Rebekah L; Riddler, Sharon A; Sax, Paul E; Sierra-Madero, Juan; Torti, Carlo; Lundgren, Jens D
2016-07-15
Previous studies suggest that nonnucleoside reverse-transcriptase inhibitors (NNRTIs) cause faster virologic suppression, while ritonavir-boosted protease inhibitors (PI/r) recover more CD4 cells. However, individual trials have not been powered to compare clinical outcomes. We searched databases to identify randomized trials that compared NNRTI- vs PI/r-based initial therapy. A metaanalysis calculated risk ratios (RRs) or mean differences (MDs), as appropriate. Primary outcome was death or progression to AIDS. Secondary outcomes were death, progression to AIDS, and treatment discontinuation. We calculated RR of virologic suppression and MD for an increase in CD4 cells at week 48. We included 29 trials with 9047 participants. Death or progression to AIDS occurred in 226 participants in the NNRTI arm and in 221 in the PI/r arm (RR, 1.03; 95% confidence interval, .87-1.22; 12 trials; n = 3825), death in 205 participants in the NNRTI arm vs 198 in the PI/r arm (1.04; 0.86-1.25; 22 trials; n = 8311), and progression to AIDS in 140 participants in the NNRTI arm vs 144 in the PI/r arm (1.00; 0.80-1.25; 13 trials; n = 4740). Overall treatment discontinuation (1.12; 0.93-1.35; 24 trials; n = 8249) and from toxicity (1.21; 0.87-1.68; 21 trials; n = 6195) were comparable, but discontinuation due to virologic failure was more common with NNRTI (1.58; 0.91-2.74; 17 trials; n = 5371). At week 48, there was no difference between NNRTI and PI/r in virologic suppression (RR, 1.03; 0.98-1.09) or CD4(+) recovery (MD, -4.7 cells; -14.2 to 4.8). We found no difference in clinical and viro-immunologic outcomes between NNRTI- and PI/r-based therapy. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.
Influence of a falling edge on high power microwave pulse combination
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Jiawei; Huang, Wenhua; Science and Technology on High Power Microwave Laboratory, Northwest Institute of Nuclear Technology, Xi'an 710024
This paper presents an explanation of the influence of a microwave falling edge on high-power microwave pulse combination. Through particle-in-cell simulations, we discover that the falling edge is the driving factor that limits the output power of the combined pulses. We demonstrate that the space charge field, which accumulates to become comparable to the E-field at the falling edge of the former pulse, will trap the electrons in the gas layer and decrease its energy to attain a high ionization rate. Hence, avalanche discharge, caused by trapped electrons, makes the plasma density to approach the critical density and cuts offmore » the latter microwave pulse. An X-band combination experiment is conducted with different pulse intervals. This experiment confirms that the high density plasma induced by the falling edge can cut off the latter pulse, and that the time required for plasma recombination in the transmission channel is several microseconds. To ensure a high output power for combined pulses, the latter pulse should be moved ahead of the falling edge of the former one, and consequently, a beat wave with high peak power becomes the output by adding two pulses with normal amplitudes.« less
Zhang, Haijuan; Zhao, Shengzhi; Yang, Kejian; Li, Guiqiu; Li, Dechun; Zhao, Jia; Wang, Yonggang
2013-09-20
A solid-state green laser generating subnanosecond pulses with adjustable kilohertz repetition rate is presented. This pulse laser system is composed of a Q-switched and mode-locked YVO(4)/Nd:YVO(4)/KTP laser simultaneously modulated by an electro-optic (EO) modulator and a central semiconductor saturable absorption mirror. Because the repetition rate of the Q-switched envelope in this laser depends on the modulation frequency of the EO modulator, so long as the pulsewidth of the Q-switched envelope is shorter than the cavity roundtrip transmit time, i.e., the time interval of two neighboring mode-locking pulses, only one mode-locking pulse exists underneath a Q-switched envelope, resulting in the generation of subnanosecond pulses with kilohertz repetition rate. The experimental results show that the pulsewidth of subnanosecond pulses decreases with increasing pump power and the shortest pulse generated at 1 kHz was 450 ps with pulse energy as high as 252 μJ, corresponding to a peak power of 560 kW. In addition, this laser was confirmed to have high stability, and the pulse repetition rate could be freely adjusted from 1 to 4 kHz.
Pulse-dose radiofrequency treatment in pain management-initial experience.
Ojango, Christine; Raguso, Mario; Fiori, Roberto; Masala, Salvatore
2018-05-01
Radiofrequency procedures have been used for treating various chronic pain conditions for decades. These minimally invasive percutaneous treatments employ an alternating electrical current with oscillating radiofrequency wavelengths to eliminate or alter pain signals from the targeted site. The aim of the continuous radiofrequency procedure is to increase the temperature sufficiently to create an irreversible thermal lesion on nerve fibres and thus permanently interrupt pain signals. The pulsed radiofrequency procedure utilises short pulses of radiofrequency current with intervals of longer pauses to avert a temperature increase to the level of permanent tissue damage. The goal of these pulses is to alter the processing of pain signals, but to avoid relevant structural damage to nerve fibres, as seen in the continuous radiofrequency procedure. The pulse-dose radiofrequency procedure is a technical improvement of the pulsed radiofrequency technique in which the delivery mode of the current is adapted. During the pulse-dose radiofrequency procedure thermal damage is avoided. In addition, the amplitude and width of the consecutive pulses are kept the same. The method ensures that each delivered pulse keeps the same characteristics and therefore the dose is similar between patients. The current review outlines the pulse-dose radiofrequency procedure and presents our institution's chronic pain management studies.
Influence of a falling edge on high power microwave pulse combination
NASA Astrophysics Data System (ADS)
Li, Jiawei; Huang, Wenhua; Zhu, Qi; Xiao, Renzhen; Shao, Hao
2016-07-01
This paper presents an explanation of the influence of a microwave falling edge on high-power microwave pulse combination. Through particle-in-cell simulations, we discover that the falling edge is the driving factor that limits the output power of the combined pulses. We demonstrate that the space charge field, which accumulates to become comparable to the E-field at the falling edge of the former pulse, will trap the electrons in the gas layer and decrease its energy to attain a high ionization rate. Hence, avalanche discharge, caused by trapped electrons, makes the plasma density to approach the critical density and cuts off the latter microwave pulse. An X-band combination experiment is conducted with different pulse intervals. This experiment confirms that the high density plasma induced by the falling edge can cut off the latter pulse, and that the time required for plasma recombination in the transmission channel is several microseconds. To ensure a high output power for combined pulses, the latter pulse should be moved ahead of the falling edge of the former one, and consequently, a beat wave with high peak power becomes the output by adding two pulses with normal amplitudes.
Triggering up states in all-to-all coupled neurons
NASA Astrophysics Data System (ADS)
Ngo, H.-V. V.; Köhler, J.; Mayer, J.; Claussen, J. C.; Schuster, H. G.
2010-03-01
Slow-wave sleep in mammalians is characterized by a change of large-scale cortical activity currently paraphrased as cortical Up/Down states. A recent experiment demonstrated a bistable collective behaviour in ferret slices, with the remarkable property that the Up states can be switched on and off with pulses, or excitations, of same polarity; whereby the effect of the second pulse significantly depends on the time interval between the pulses. Here we present a simple time-discrete model of a neural network that exhibits this type of behaviour, as well as quantitatively reproduces the time dependence found in the experiments.
SABRE observations of Pi2 pulsations: case studies
NASA Astrophysics Data System (ADS)
Bradshaw, E. G.; Lester, M.
1997-01-01
The characteristics of substorm-associated Pi2 pulsations observed by the SABRE coherent radar system during three separate case studies are presented. The SABRE field of view is well positioned to observe the differences between the auroral zone pulsation signature and that observed at mid-latitudes. During the first case study the SABRE field of view is initially in the eastward electrojet, equatorward and to the west of the substorm-enhanced electrojet current. As the interval progresses, the western, upward field-aligned current of the substorm current wedge moves westward across the longitudes of the radar field of view. The westward motion of the wedge is apparent in the spatial and temporal signatures of the associated Pi2 pulsation spectra and polarisation sense. During the second case study, the complex field-aligned and ionospheric currents associated with the pulsation generation region move equatorward into the SABRE field of view and then poleward out of it again after the third pulsation in the series. The spectral content of the four pulsations during the interval indicate different auroral zone and mid-latitude signatures. The final case study is from a period of low magnetic activity when SABRE observes a Pi2 pulsation signature from regions equatorward of the enhanced substorm currents. There is an apparent mode change between the signature observed by SABRE in the ionosphere and that on the ground by magnetometers at latitudes slightly equatorward of the radar field of view. The observations are discussed in terms of published theories of the generation mechanisms for this type of pulsation. Different signatures are observed by SABRE depending on the level of magnetic activity and the position of the SABRE field of view relative to the pulsation generation region. A twin source model for Pi2 pulsation generation provides the clearest explanation of the signatures observed Acknowledgements. The authors are grateful to Prof. D. J. Southwood (Imperial College, London), J. C. Samson (University of Alberta, Edmonton), L. J. Lanzerotti (AT&T Bell Laboratories), A. Wolfe (New York City Technical College) and to Dr. M. Vellante (University of LÁquila) for helpful discussions. They also thank Dr. A. Meloni (Istituto Nazionale di Geofisica, Roma) who made available geomagnetic field observations from LÁquila Geomagnetic Observatory. This research activity at LÁquila is supported by MURST (40% and 60% contracts) and by GIFCO/CNR. Topical Editor K.-H. Glaßmeier thanks C. Waters and S. Fujita for their help in evaluating this paper.-> Correspondence to :P. Francia->
Real-time multiplicity counter
Rowland, Mark S [Alamo, CA; Alvarez, Raymond A [Berkeley, CA
2010-07-13
A neutron multi-detector array feeds pulses in parallel to individual inputs that are tied to individual bits in a digital word. Data is collected by loading a word at the individual bit level in parallel. The word is read at regular intervals, all bits simultaneously, to minimize latency. The electronics then pass the word to a number of storage locations for subsequent processing, thereby removing the front-end problem of pulse pileup.
Reconstruction of Sea State One
1988-02-01
this section only a general overview of the wave computer system will be offered. A more comprehensive treatment of this subject is available in Appendix...1) Sync Strip and Threshold Processing Card (2) Pulse Generation Logic Card (3) X Vector Logic Card (4) Y Vector Logic Card (5) Blanking Interval...output by this comparator when the threshold is crossed, which shall be referred to as threshold crossing (THC). (2) PULSE GENERATION LOGIC CARD Turning
Numerical investigation of trichel pulse of negative corona discharge in N2-O2 mixture
NASA Astrophysics Data System (ADS)
Xia, Qing; Zhang, Yu; Jiang, Zhaorui; Wang, Ronggang; Ouyang, Jiting
2017-12-01
Trichel pulse of negative corona discharge in atmospheric air is investigated numerically using a 2D fluid model. The model consists of a hyperbolic cathode tip and a plane anode, and considers 11 kinds of particles and the most important interactions among them. The spatio-temporal evolution of charged species and the electric field are evaluated during the pulse process. During the pulse rising edge, the positive ions accumulate ahead of the tip forming the temporal cathode sheath, significantly enhancing the local field. In the pulse decay edge, the temporal sheath collapses and the discharge falls back to a low-current mode. In the pulse interval, the discharge does not cease but sustains weakly until the next pulse. The location of the temporal sheath is independent of the averaged value during the Trichel pulse regime and also the same with that in a normal glow regime, which determines a nearly constant pulse rising time at given configurations. However, a smaller tip radius will lead to their decrease. The effect of negative ions on the pulse process is studied by adjusting the attachment rates. It indicates that the negative ions are actually not necessary in the Trichel pulse process, but will influence the pulse waveform significantly.
Rafati, A; Rahimi, S; Talebi, A; Soleimani, A; Haghani, M; Mortazavi, S M J
2015-09-01
The rapid growth of wireless communication technologies has caused public concerns regarding the biological effects of electromagnetic radiations on human health. Some early reports indicated a wide variety of non-thermal effects of electromagnetic radiation on amphibians such as the alterations of the pattern of muscle extractions. This study is aimed at investigating the effects of exposure to radiofrequency (RF) radiation emitted from mobile phone jammers on the pulse height of contractions, the time interval between two subsequent contractions and the latency period of frog's isolated gastrocnemius muscle after stimulation with single square pulses of 1V (1 Hz). Frogs were kept in plastic containers in a room. Animals in the jammer group were exposed to radiofrequency (RF) radiation emitted from a common Jammer at a distance of 1m from the jammer's antenna for 2 hours while the control frogs were only sham exposed. Then animals were sacrificed and isolated gastrocnemius muscles were exposed to on/off jammer radiation for 3 subsequent 10 minute intervals. Isolated gastrocnemius muscles were attached to the force transducer with a string. Using a PowerLab device (26-T), the pattern of muscular contractions was monitored after applying single square pulses of 1V (1 Hz) as stimuli. The findings of this study showed that the pulse height of muscle contractions could not be affected by the exposure to electromagnetic fields. However, the latency period was effectively altered in RF-exposed samples. However, none of the experiments could show an alteration in the time interval between two subsequent contractions after exposure to electromagnetic fields. These findings support early reports which indicated a wide variety of non-thermal effects of electromagnetic radiation on amphibians including the effects on the pattern of muscle extractions.
Hiscock, R; Kumar, D; Simmons, S W
2015-05-01
We assessed agreement in haemoglobin measurement between Masimo pulse co-oximeters (Rad-7™ and Pronto-7™) and HemoCue® photometers (201+ or B-Hemoglobin) with laboratory-based determination and identified 39 relevant studies (2915 patients in Masimo group and 3084 patients in HemoCue group). In the Masimo group, the overall mean difference was -0.03 g/dl (95% prediction interval -0.30 to 0.23) and 95% limits of agreement -3.0 to 2.9 g/dl compared to 0.08 g/dl (95% prediction interval -0.04 to 0.20) and 95% limits of agreement -1.3 to 1.4 g/dl in the HemoCue group. Only B-Hemoglobin exhibited bias (0.53, 95% prediction interval 0.27 to 0.78). The overall standard deviation of difference was larger (1.42 g/dl versus 0.64 g/dl) for Masimo pulse co-oximeters compared to HemoCue photometers. Masimo devices and HemoCue 201+ both provide an unbiased, pooled estimate of laboratory haemoglobin. However, Masimo devices have lower precision and wider 95% limits of agreement than HemoCue devices. Clinicians should carefully consider these limits of agreement before basing transfusion or other clinical decisions on these point-of-care measurements alone.
Carlyon, Robert P.; Long, Christopher J.; Deeks, John M.
2008-01-01
Experiment 1 measured rate discrimination of electric pulse trains by bilateral cochlear implant (CI) users, for standard rates of 100, 200, and 300 pps. In the diotic condition the pulses were presented simultaneously to the two ears. Consistent with previous results with unilateral stimulation, performance deteriorated at higher standard rates. In the signal interval of each trial in the dichotic condition, the standard rate was presented to the left ear and the (higher) signal rate was presented to the right ear; the non-signal intervals were the same as in the diotic condition. Performance in the dichotic condition was better for some listeners than in the diotic condition for standard rates of 100 and 200 pps, but not at 300 pps. It is concluded that the deterioration in rate discrimination observed for CI users at high rates cannot be alleviated by the introduction of a binaural cue, and is unlikely to be limited solely by central pitch processes. Experiment 2 performed an analogous experiment in which 300-pps acoustic pulse trains were bandpass filtered (3900-5400 Hz) and presented in a noise background to normal-hearing listeners. Unlike the results of experiment 1, performance was superior in the dichotic than in the diotic condition. PMID:18397032
Tan, Chengcheng; Li, Genqiao; Cowger, Christina; Carver, Brett F; Xu, Xiangyang
2018-05-01
A new powdery mildew resistance gene, designated Pm59, was identified in Afghanistan wheat landrace PI 181356, and mapped in the terminal region of the long arm of chromosome 7A. Powdery mildew, caused by Blumeria graminis f. sp. tritici (Bgt), is an important foliar disease of wheat worldwide. In the Great Plains of the USA, Bgt isolates virulent to widely used powdery mildew resistance genes, such as Pm3a, were previously identified. The objectives of this study were to characterize the powdery mildew resistance gene in Afghanistan landrace PI 181356, which exhibited high resistance to Bgt isolates collected in southern Great Plains, and identify molecular markers for marker-assisted selection. An F 2 population and F 2:3 lines derived from a cross between PI 181356 and OK1059060-126135-3 were used in this study. Genetic analysis indicated that PI 181356 carries a single dominant gene, designated Pm59, in the terminal region of the long arm of chromosome 7A. Pm59 was mapped to an interval between sequence tag site (STS) markers Xmag1759 and Xmag1714 with genetic distances of 0.4 cM distal to Xmag1759 and 5.7 cM proximal to Xmag1714. Physical mapping suggested that Pm59 is in the distal bin 7AL 0.99-1.00. Pm59 is a novel powdery mildew resistance gene, and confers resistance to Bgt isolates collected from the Great Plains and the state of Montana. Therefore, Pm59 can be used to breed powdery mildew-resistant cultivars in these regions. Xmag1759 is ideal for marker-assisted selection of Pm59 in wheat breeding.
Briand, Nelly; Mandelbrot, Laurent; Blanche, Stéphane; Tubiana, Roland; Faye, Albert; Dollfus, Catherine; Le Chenadec, Jérôme; Benhammou, Valérie; Rouzioux, Christine; Warszawski, Josiane
2011-06-01
Few data are available on the possible long-term negative effects of a short exposure to antiretroviral therapy (ART) for prevention of mother-to-child transmission (PMTCT). To determine whether ART for PMTCT, discontinued after delivery, affects the virological response to highly active antiretroviral therapy (HAART) administered during subsequent pregnancies. All current pregnancies of HIV-1-infected women enrolled in the French Perinatal Cohort (ANRS CO-01 EPF) between 2005 and 2009 and not receiving ART at the time of conception were eligible. We studied the association between history of exposure to ART during a previous pregnancy and detectable viral load (VL) under multitherapy at current delivery (VL ≥ 50 copies/mL). Among 1116 eligible women, 869 were ART naive and 247 had received PMTCT during a previous pregnancy. Previous ART was protease inhibitor (PI)-based HAART in 48%, non-PI-based HAART in 4%, nucleoside reverse transcriptase inhibitor bitherapy in 19% and zidovudine monotherapy in 29% of the women. At current pregnancy, women with or without prior exposure to ART had similar CD4 cell counts and VL before ART initiation. PI-based HAART was initiated in 90% of the women. VL was undetectable (<50 copies/mL) at delivery in 65% of previously ART-naive women, 72% of women previously exposed to HAART, 62% previously exposed to bitherapy, and 67% previously exposed to monotherapy for prophylaxis (P = 0.42). Detectable VL was not associated with previous exposure in multivariate analysis (adjusted OR for previous versus no previous exposure to ART: 0.92; 0.95% confidence interval: 0.59 to 1.44). Efficacy of PI-based combinations is not decreased in women previously exposed to various regimens of antiretroviral PMTCT.
Mapping resistance to the Ug99 race group of the stem rust pathogen in a spring wheat landrace.
Babiker, E M; Gordon, T C; Chao, S; Newcomb, M; Rouse, M N; Jin, Y; Wanyera, R; Acevedo, M; Brown-Guedira, G; Williamson, S; Bonman, J M
2015-04-01
A new gene for Ug99 resistance from wheat landrace PI 374670 was detected on the long arm of chromosome 7A. Wheat landrace PI 374670 has seedling and field resistance to stem rust caused by Puccinia graminis f. sp tritici Eriks. & E. Henn (Pgt) race TTKSK. To elucidate the inheritance of resistance, 216 BC1F2 families, 192 double haploid (DH) lines, and 185 recombinant inbred lines (RILs) were developed by crossing PI 374670 and the susceptible line LMPG-6. The parents and progeny were evaluated for seedling resistance to Pgt races TTKSK, MCCFC, and TPMKC. The DH lines were tested in field stem rust nurseries in Kenya and Ethiopia. The DH lines were genotyped with the 90K wheat iSelect SNP genotyping platform. Goodness-of-fit tests indicated that a single dominant gene in PI 374670 conditioned seedling resistance to the three Pgt races. The seedling resistance locus mapped to the long arm of chromosome 7A and this result was verified in the RIL population screened with the flanking SNP markers using KASP assays. In the same region, a major QTL for field resistance was detected in a 7.7 cM interval and explained 34-54 and 29-36% of the variation in Kenya and Ethiopia, respectively. Results from tests with specific Pgt races and the csIH81 marker showed that the resistance was not due to Sr22. Thus, a new stem rust resistance gene or allele, either closely linked or allelic to Sr15, is responsible for the seedling and field resistance of PI 374670 to Ug99.
Ozone and daily mortality rate in 21 cities of East Asia: how does season modify the association?
Chen, Renjie; Cai, Jing; Meng, Xia; Kim, Ho; Honda, Yasushi; Guo, Yue Leon; Samoli, Evangelia; Yang, Xin; Kan, Haidong
2014-10-01
Previous studies in East Asia have revealed that the short-term associations between tropospheric ozone and daily mortality rate were strongest in winter, which is opposite to the findings in North America and Western Europe. Therefore, we investigated the season-varying association between ozone and daily mortality rate in 21 cities of East Asia from 1979 to 2010. Time-series Poisson regression models were used to analyze the association between ozone and daily nonaccidental mortality rate in each city, testing for different temperature lags. The best-fitting model was obtained after adjustment for temperature in the previous 2 weeks. Bayesian hierarchical models were applied to pool the city-specific estimates. An interquartile-range increase of the moving average concentrations of same-day and previous-day ozone was associated with an increase of 1.44% (95% posterior interval (PI): 1.08%, 1.80%) in daily total mortality rate after adjustment for temperature in the previous 2 weeks. The corresponding increases were 0.62% (95% PI: 0.08%, 1.16%) in winter, 1.46% (95% PI: 0.89%, 2.03%) in spring, 1.60% (95% PI: 1.03%, 2.17%) in summer, and 1.12% (95% PI: 0.73%, 1.51%) in fall. We found significant associations between short-term exposure to ozone and higher mortality rate in East Asia that varied considerably from season to season with a significant trough in winter. © The Author 2014. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Peterson, Cora; Grosse, Scott D; Li, Rui; Sharma, Andrea J; Razzaghi, Hilda; Herman, William H; Gilboa, Suzanne M
2015-01-01
Preconception care for women with diabetes can reduce the occurrence of adverse birth outcomes. We aimed to estimate the preconception care (PCC)-preventable health and cost burden of adverse birth outcomes associated with diagnosed and undiagnosed pregestational diabetes mellitus (PGDM) in the United States. Among women of reproductive age (15-44 years), we estimated age- and race/ethnicity-specific prevalence of diagnosed and undiagnosed diabetes. We applied age and race/ethnicity-specific pregnancy rates, estimates of the risk reduction from PCC for 3 adverse birth outcomes (preterm birth, major birth defects, and perinatal mortality), and lifetime medical and lost productivity costs for children with those outcomes. Using a probabilistic model, we estimated the reduction in adverse birth outcomes and costs associated with universal PCC compared with no PCC among women with PGDM. We did not assess maternal outcomes and associated costs. We estimated 2.2% of US births are to women with PGDM. Among women with diagnosed diabetes, universal PCC might avert 8397 (90% prediction interval [PI], 5252-11,449) preterm deliveries, 3725 (90% PI, 3259-4126) birth defects, and 1872 (90% PI, 1239-2415) perinatal deaths annually. Associated discounted lifetime costs averted for the affected cohort of children could be as high as $4.3 billion (90% PI, 3.4-5.1 billion) (2012 US dollars). PCC among women with undiagnosed diabetes could yield an additional $1.2 billion (90% PI, 951 million-1.4 billion) in averted cost. Results suggest a substantial health and cost burden associated with PGDM that could be prevented by universal PCC, which might offset the cost of providing such care. Published by Elsevier Inc.
Pere, Domingo; Ignacio, Suarez-Lozano; Ramón, Teira; Fernando, Lozano; Alberto, Terrón; Pompeyo, Viciana; Juan, González; M José, Galindo; Paloma, Geijo; Antonio, Vergara; Jaime, Cosín; Esteban, Ribera; Bernardino, Roca; M Luisa, Garcia-Alcalde; Trinitario, Sánchez; Ferran, Torres; Juan Ramón, Lacalle; Myriam, Garrido
2008-01-01
There is increasing evidence that metabolic adverse effects associated with antiretroviral therapy may translate into an increased cardiovascular risk in HIV-1-infected patients. To determine the prevalence of risk factors for cardiovascular disease (CVD) among HIV-1-infected persons, and to investigate any association between them, stage of HIV-1 disease, and use of antiretroviral therapies. Multicentric, cross-sectional analysis of CVD risk factors of treated patients in the VACH cohort. The data collected includes: demographic variables, cigarette smoking, diabetes mellitus, hypertension, dyslipidemia, body mass index, stage of HIV-1 infection, and antiretroviral therapy. The analysis included 2358 patients. More than 18% of the study population was at an age of appreciable risk of CVD. 1.7% had previous CVD and 59.2% were smokers. Increased prevalence of elevated total cholesterol was observed among subjects receiving an NNRTI but no PI [odds ratio (OR), 3.34; 95% confidence interval (CI), 1.77-6.31], PI but no NNRTI (OR, 4.04; 95% CI, 2.12-7.71), or NNRTI + PI (OR, 17.77; 95% CI, 7.24-43.59) compared to patients treated only with nucleoside reverse transcriptase inhibitors (NRTI). Higher CD4 cell count, lower plasma HIV-1 RNA levels, clinical signs of lipodystrophy, longer exposure times to NNRTI and PI, and older age were all also associated with elevated cholesterol levels. The use of lipid lowering agents was very low among our patients. Patients in the VACH cohort present multiple known risk factors for CVD, and a very low rate of lipid lowering therapy use. NNRTI and/or PI-based antiretroviral therapies are associated with the worst lipid profile. This is more frequent in older subjects with greater CD4 counts and controlled HIV-1 replication.
Koh, Young-Youp; Kim, Hyung Ho; Choi, Dong-Hyun; Lee, Young-Min; Ki, Young-Jae; Kang, Seong-Ho; Park, Geon; Chung, Joong-Wha; Chang, Kyong-Sig; Hong, Soon-Pyo
2015-01-01
We aimed to determine the association between the change in mean platelet volume (MPV) over time and aspirin/ clopidogrel resistance in patients undergoing percutaneous coronary intervention (PCI). The MPV and platelet function were analysed in 302 patients who underwent PCI. MPV changes were associated with increased aspirin reaction units (ARU, r = 0.114; P = 0.047), increased P2Y12 reaction units (PRU, r = 0.193; P = 0.001), and decreased P2Y12% inhibition (PI%, r = - 0.273; P < 0.001). The group with increasing MPV values showed significantly higher PRU values and lower PI% compared with the group with decreasing MPV values (222.5 ± 73.9 vs. 195.6 ± 63.7 PRU, P = 0.001; 24.1 ± 21.0 vs. 32.8 ± 18.5 PI%, P < 0.001, respectively). The clopidogrel resistant group (≥235 PRU or ≤15% of PI%) showed a significantly higher positive change in MPV (ΔMPV) values than the clopidogrel responder group (0.53 ± 0.78 vs. 0.13 ± 0.69 fL, P < 0.001). When the ΔMPV cut-off level was set at 0.20 fL using the receiver operating characteristic curve, the sensitivity and specificity for differentiating between the clopidogrel resistant and responder groups were 72.6% and 59.3%, respectively. After adjusting for traditional risk factors, the odds ratio in the clopidogrel resistant group with ΔMPV ≥0.2 fL was 4.10 (95% confidence interval; 1.84-9.17). In conclusion, ΔMPV was associated with PRU and PI%; a positive ΔMPV was an independent predictive marker for clopidogrel resistance after PCI.
Dynamical Localization for Discrete and Continuous Random Schrödinger Operators
NASA Astrophysics Data System (ADS)
Germinet, F.; De Bièvre, S.
We show for a large class of random Schrödinger operators Ho on and on that dynamical localization holds, i.e. that, with probability one, for a suitable energy interval I and for q a positive real,
Jiang, Ai-Gui; Chen, Hong-Lin; Lu, Hui-Yu
2015-03-01
Previous studies have shown that Glasgow prognostic score (GPS) and prognostic index (PI) are also powerful prognostic tool for patients with advanced non-small cell lung cancer (NSCLC). The aim of this study was to compare the prognostic value between GPS and PI. We enrolled consecutive patients with advanced NSCLC in this prospective cohort. GPS and PI were calculated before the onset of chemotherapy. The prognosis outcomes included 1-, 3-, and 5-year progression-free survival and overall survival (OS). The performance of two scores in predicting prognosis was analyzed regarding discrimination and calibration. 138 patients were included in the study. The area under the receiver operating characteristic curve for GPS predicting 1-year DFS was 0.62 (95 % confidence interval (CI) 0.56-0.68, P < 0.05), and the area under curve for PI predicting 1-year DFS was 0.57 (95 % CI 0.52-0.63). Delong's test showed that GPS was more accurate than PI in predicting 1-year DFS (P < 0.05). Similar results of discriminatory power were found for predicting 3-year DFS, 1-year OS, and 3-year OS. The predicted 1-year DFS by GPS 0, GPS 1, and GPS 2 were 62.5, 42.1, and 23.1 %, respectively, while actual 1-year DFS by GPS 0, GPS 1, and GPS 2 were 61.1, 43.8, and 27.2 %, respectively. Calibration of the Hosmer and Lemeshow statistic showed good fit of the predicted 1-year DFS to the actual 1-year DFS by GPS (χ(2) = 4.326, P = 0.462), while no fit was found between the predicted 1-year DFS and the actual 1-year DFS by PI (χ(2) = 15.234, P = 0.091). Similar results of calibration power were found for predicting 3-year DFS, 5-year DFS, 1-year OS, 3-year OS, and 5-year OS by GPS and PI. GPS is more accurate than PI in predicting prognosis for patients with advanced NSCLC. GPS can be used as a useful and simple tool for predicting prognosis in patients with NSCLC. However, GPS only can be used for preliminary assessment because of low predicting accuracy.
Petahertz optical oscilloscope
NASA Astrophysics Data System (ADS)
Kim, Kyung Taec; Zhang, Chunmei; Shiner, Andrew D.; Schmidt, Bruno E.; Légaré, François; Villeneuve, D. M.; Corkum, P. B.
2013-12-01
The time-dependent field of an electromagnetic pulse can be measured if there is a fast enough gate. For terahertz radiation, femtosecond photoinjection of free carriers into a semiconductor in the presence of the terahertz radiation can serve as the gate. For visible or infrared radiation, attosecond photoionization of a gas target in the presence of the optical field is a direct analogue. Here, we show that nonlinear optical mixing in a medium in which attosecond pulses are being generated can also be used to measure the time-dependent field of an optical pulse. The gate is the phase accumulated by the recollision electron during the subcycle time interval between ionization and recombination. We show that the instantaneous field of an unknown pulse is imprinted onto the deflection of the attosecond extreme ultraviolet pulse using an all-optical set-up with a bandwidth up to 1 PHz.
Effect of current on the maximum possible reward.
Gallistel, C R; Leon, M; Waraczynski, M; Hanau, M S
1991-12-01
Using a 2-lever choice paradigm with concurrent variable interval schedules of reward, it was found that when pulse frequency is increased, the preference-determining rewarding effect of 0.5-s trains of brief cathodal pulses delivered to the medial forebrain bundle of the rat saturates (stops increasing) at values ranging from 200 to 631 pulses/s (pps). Raising the current lowered the saturation frequency, which confirms earlier, more extensive findings showing that the rewarding effect of short trains saturates at pulse frequencies that vary from less than 100 pps to more than 800 pps, depending on the current. It was also found that the maximum possible reward--the magnitude of the reward at or beyond the saturation pulse frequency--increases with increasing current. Thus, increasing the current reduces the saturation frequency but increases the subjective magnitude of the maximum possible reward.
Kisspeptin and LH pulsatile temporal coupling in PCOS patients.
Katulski, Krzysztof; Podfigurna, Agnieszka; Czyzyk, Adam; Meczekalski, Blazej; Genazzani, Alessandro D
2018-05-04
To evaluate the temporal coupling between spontaneous kisspeptin and luteinizing hormone (LH) pulsatile releases in polycystic ovary syndrome (PCOS) patients. We examined 71 patients diagnosed with PCOS. A 2 h pulsatility study was performed to evaluate serum kisspeptin and LH pulse frequency and concentration, sampled every 10 min; baseline follicle-stimulating hormone (FSH), estradiol (E2), prolactin (PRL), cortisol, 17-hydroksy-progesterone (17OHP), testosterone (T), free testosterone index (FTI, and insulin levels were also measured. Detect and Specific Concordance (SC) algorithms were used to evaluate the temporal coupling associations between spontaneous episodic secretion of kisspeptin and LH. All PCOS patients demonstrated LH and kisspeptin pulsatile secretions. When the SC index was calculated across the sample of PCOS patients (n = 71), no temporal coupling was observed between kisspeptin and LH pulses. When PCOS patients were subdivided according to their menstrual cyclicity, oligomenorrheic patients demonstrated elevated kisspeptin pulse frequency. Additionally, the SC index reveled a temporal coupling between kisspeptin and LH secretory peaks only in eumenorrheic patients (n = 30, intermenstrual interval < 45 days). Oligomenorrheic PCOS patients (intermenstrual interval > 45 days) did not demonstrate temporal coupling between kisspeptin and LH secretory peaks. The study of the endogenous kisspeptin and LH pulsatile release revealed the temporal coupling of kisspeptin with LH secretory pulses only in eumenorrheic. This data supports the hypothesis that neuroendocrine impairments in PCOS affect the coupling of kisspeptin with LH pulses and potentially worsen as the disease progresses, becoming unequivocally evident in oligomenorrheic PCOS patients.
NASA Astrophysics Data System (ADS)
Iravani, Hossein; Sabzyan, Hassan; Vafaee, Mohsen; Buzari, Behnaz
2018-04-01
Contributions of the pre-ionized H2 (PI-H2) and ionized {{{H}}}2+ subsystems of the two-electron H2 system to its high-order harmonic generation in eight-cycle sin2-like ultrafast intense laser pulses are calculated and analyzed based on the solution of the time-dependent Schrödinger equation for the one-dimensional two-electronic H2 system with fixed nuclei. The laser pulses have λ = 390 and 532 nm wavelengths and I = 1 × 1014, 5 × 1014, 1 × 1015 and 5 × 1015 W cm‑2 intensities. It is found that at the two lower intensities, the PI-H2 subsystem dominantly produces the HHG spectra. However, at the two higher intensities, both PI-H2 and ionized {{{H}}}2+ subsystems contribute comparably to the HHG spectra. In the {{{H}}}2+ subsystem, the symmetry of the populations of {{{H}}}2+(I) and {{{H}}}2+(II) regions (left and right regions of {{{H}}}2+ subsystem) is broken by increasing the laser intensity. Complex patterns and even harmonics also appear at these two higher intensities. For instance, at 1 × 1015 W cm‑2 intensity and λ = 532 nm wavelength, the even harmonics are appeared near cutoff region. Interestingly, at 5 × 1015 W cm‑2 intensity and λ = 390 nm wavelength, the even harmonics replaced by the odd harmonics with red shift. At λ = 390 and 532 nm wavelengths and I = 1 × 1015 intensity, the two-electron cutoffs corresponding to nonsequential double-recombination with maximum return kinetic energy of 4.70Up are detected. The HHG spectra of the whole H2 system obtained with and without nuclear dynamics treated classically are approximately similar. However, at 1 × 1015 W cm‑2 intensity and λ = 532 nm wavelength, if we take into account nuclear dynamics, the even harmonics which are appeared near cutoff region, replaced by the odd harmonics with blue shift.
Atom interferometric gravity gradiometer: Disturbance compensation and mobile gradiometry
NASA Astrophysics Data System (ADS)
Mahadeswaraswamy, Chetan
First ever mobile gravity gradient measurement based on Atom Interferometric sensors has been demonstrated. Mobile gravity gradiometers play a significant role in high accuracy inertial navigation systems in order to distinguish inertial acceleration and acceleration due to gravity. The gravity gradiometer consists of two atom interferometric accelerometers. In each of the accelerometer an ensemble of laser cooled Cesium atoms is dropped and using counter propagating Raman pulses (pi/2-pi-pi/2) the ensemble is split into two states for carrying out atom interferometry. The interferometer phase is proportional to the specific force experienced by the atoms which is a combination of inertial acceleration and acceleration due to gravity. The difference in phase between the two atom interferometric sensors is proportional to gravity gradient if the platform does not undergo any rotational motion. However, any rotational motion of the platform induces spurious gravity gradient measurements. This apparent gravity gradient due to platform rotation is considerably different for an atom interferometric sensor compared to a conventional force rebalance type sensor. The atoms are in free fall and are not influenced by the motion of the case except at the instants of Raman pulses. A model for determining apparent gravity gradient due to rotation of platform was developed and experimentally verified for different frequencies. This transfer function measurement also lead to the development of a new technique for aligning the Raman laser beams with the atom clusters to within 20 mu rad. This gravity gradiometer is situated in a truck for the purpose of undertaking mobile surveys. A disturbance compensation system was designed and built in order to compensate for the rotational disturbances experienced on the floor of a truck. An electric drive system was also designed specifically to be able to move the truck in a uniform motion at very low speeds of about 1cm/s. A 250 x10-9 s-2 gravity gradient signature due to an underground void at Hansen Experimental Physics Building at Stanford was successfully measured using this mobile gradiometer.
Saini, V K; Kumar, P; Dixit, S K; Nakhe, S V
2015-02-01
Laser-assisted Penning ionization (LAPI) is detected in a Ne/Eu hollow cathode (HC) discharge lamp using the pulsed optogalvanic (OG) method. In the Ne/Eu discharge, doubly ionized europium excited energy levels Eu[4f(7)(P(7/2,5/2)6)] lie within the thermal limit (∼kT) from the laser-excited neon's energy level [2p(5)(P3/202)3p or 2p(8) (in Paschen notation)] lying at 149,848 cm(-1). Therefore, Penning ionization (PI) of europium atoms likely to occur into its highly excited ionic states is investigated. To probe the PI of europium, the temporal profiles of its counterpart neon OG signal are studied as a function of discharge current for the transitions (1s(4)→2p(8)) and (1s(2)→2p(2)), corresponding to 650.65 and 659.89 nm wavelengths, respectively. It is observed that PI of europium alters the overall discharge characteristics significantly and, hence, modifies the temporal profile of the OG signals accordingly. The quasi-resonant ionizing energy transfer collisions between laser-excited Ne 2p(8) atoms and electronically excited europium P(9/2)10 atoms are used to explain the LAPI mechanism. Such LAPI studies carried out in HC discharge could be useful for the discharge of a metal-vapor laser with appropriate Penning mixtures.
SIRENA software for Athena X-IFU event reconstruction
NASA Astrophysics Data System (ADS)
Ceballos, M. T.; Cobo, B.; Peille, P.; Wilms, J.; Brand, T.; Dauser, T.; Bandler, S.; Smith, S.
2017-03-01
The X-ray Observatory Athena was proposed in April 2014 as the mission to implement the science theme "The Hot and Energetic Universe" selected by ESA for L2 (the second Large-class mission in ESA’s Cosmic Vision science programme). One of the two X-ray detectors designed to be onboard Athena is X-IFU, a cryogenic microcalorimeter based on Transition Edge Sensor (TES) technology that will provide spatially resolved high-resolution spectroscopy. X-IFU will be developed by an international consortium led by IRAP (PI), SRON (co-PI) and IAPS/INAF (co-PI) and involving ESA Member States, Japan and the United States. In Spain, IFCA (CSIC-UC) has an anticipated contribution to X-IFU through the Digital Readout Electronics (DRE) unit, in particular in the Event Processor Subsystem. For this purpose and in collaboration with the Athena end-to-end simulations team, we are currently developing the SIRENA package as part of the publicly available SIXTE end-to-end simulator. SIRENA comprises a set of processing algorithms aimed at recognizing, from a noisy signal, the intensity pulses generated by the absorption of the X-ray photons, to lately reconstruct their energy, position and arrival time. This poster describes the structure of the package and the different algorithms currently implemented as well as their comparative performance in the energy resolution achieved in the reconstruction of the instrument events.
Dead-time compensation for a logarithmic display rate meter
Larson, John A.; Krueger, Frederick P.
1988-09-20
An improved circuit is provided for application to a radiation survey meter that uses a detector that is subject to dead time. The circuit compensates for dead time over a wide range of count rates by producing a dead-time pulse for each detected event, a live-time pulse that spans the interval between dead-time pulses, and circuits that average the value of these pulses over time. The logarithm of each of these values is obtained and the logarithms are subtracted to provide a signal that is proportional to a count rate that is corrected for the effects of dead time. The circuit produces a meter indication and is also capable of producing an audible indication of detected events.
Dead-time compensation for a logarithmic display rate meter
Larson, J.A.; Krueger, F.P.
1987-10-05
An improved circuit is provided for application to a radiation survey meter that uses a detector that is subject to dead time. The circuit compensates for dead time over a wide range of count rates by producing a dead-time pulse for each detected event, a live-time pulse that spans the interval between dead-time pulses, and circuits that average the value of these pulses over time. The logarithm of each of these values is obtained and the logarithms are subtracted to provide a signal that is proportional to a count rate that is corrected for the effects of dead time. The circuit produces a meter indication and is also capable of producing an audible indication of detected events. 5 figs.
NASA Astrophysics Data System (ADS)
Kargovsky, A. V.; Chichigina, O. A.; Anashkina, E. I.; Valenti, D.; Spagnolo, B.
2015-10-01
The relaxation dynamics of a system described by a Langevin equation with pulse multiplicative noise sources with different correlation properties is considered. The solution of the corresponding Fokker-Planck equation is derived for Gaussian white noise. Moreover, two pulse processes with regulated periodicity are considered as a noise source: the dead-time-distorted Poisson process and the process with fixed time intervals, which is characterized by an infinite correlation time. We find that the steady state of the system is dependent on the correlation properties of the pulse noise. An increase of the noise correlation causes the decrease of the mean value of the solution at the steady state. The analytical results are in good agreement with the numerical ones.
Kargovsky, A V; Chichigina, O A; Anashkina, E I; Valenti, D; Spagnolo, B
2015-10-01
The relaxation dynamics of a system described by a Langevin equation with pulse multiplicative noise sources with different correlation properties is considered. The solution of the corresponding Fokker-Planck equation is derived for Gaussian white noise. Moreover, two pulse processes with regulated periodicity are considered as a noise source: the dead-time-distorted Poisson process and the process with fixed time intervals, which is characterized by an infinite correlation time. We find that the steady state of the system is dependent on the correlation properties of the pulse noise. An increase of the noise correlation causes the decrease of the mean value of the solution at the steady state. The analytical results are in good agreement with the numerical ones.
Greer, Matthew D; Shih, Joanna H; Barrett, Tristan; Bednarova, Sandra; Kabakus, Ismail; Law, Yan Mee; Shebel, Haytham; Merino, Maria J; Wood, Bradford J; Pinto, Peter A; Choyke, Peter L; Turkbey, Baris
2018-01-17
Prostate imaging reporting and data system version 2 (PI-RADSv2) recommends a sector map for reporting findings of prostate cancer mulitparametric MRI (mpMRI). Anecdotally, radiologists may demonstrate inconsistent reproducibility with this map. To evaluate interobserver agreement in defining prostate tumor location on mpMRI using the PI-RADSv2 sector map. Retrospective. Thirty consecutive patients who underwent mpMRI between October, 2013 and March, 2015 and who subsequently underwent prostatectomy with whole-mount processing. 3T mpMRI with T 2 W, diffusion-weighted imaging (DWI) (apparent diffusion coefficient [ADC] and b-2000), dynamic contrast-enhanced (DCE). Six radiologists (two high, two intermediate, and two low experience) from six institutions participated. Readers were blinded to lesion location and detected up to four lesions as per PI-RADSv2 guidelines. Readers marked the long-axis of lesions, saved screen-shots of each lesion, and then marked the lesion location on the PI-RADSv2 sector map. Whole-mount prostatectomy specimens registered to the MRI served as ground truth. Index lesions were defined as the highest grade lesion or largest lesion if grades were equivalent. Agreement was calculated for the exact, overlap, and proportion of agreement. Readers detected an average of 1.9 lesions per patient (range 1.6-2.3). 96.3% (335/348) of all lesions for all readers were scored PI-RADS ≥3. Readers defined a median of 2 (range 1-18) sectors per lesion. Agreement for detecting index lesions by screen shots was 83.7% (76.1%-89.9%) vs. 71.0% (63.1-78.3%) overlap agreement on the PI-RADS sector map (P < 0.001). Exact agreement for defining sectors of detected index lesions was only 21.2% (95% confidence interval [CI]: 14.4-27.7%) and rose to 49.0% (42.4-55.3%) when overlap was considered. Agreement on defining the same level of disease (ie, apex, mid, base) was 61.4% (95% CI 50.2-71.8%). Readers are highly likely to detect the same index lesion on mpMRI, but exhibit poor reproducibility when attempting to define tumor location on the PI-RADSv2 sector map. The poor agreement of the PI-RADSv2 sector map raises concerns its utility in clinical practice. 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.
A probabilistic neural network based approach for predicting the output power of wind turbines
NASA Astrophysics Data System (ADS)
Tabatabaei, Sajad
2017-03-01
Finding the authentic predicting tools of eliminating the uncertainty of wind speed forecasts is highly required while wind power sources are strongly penetrating. Recently, traditional predicting models of generating point forecasts have no longer been trustee. Thus, the present paper aims at utilising the concept of prediction intervals (PIs) to assess the uncertainty of wind power generation in power systems. Besides, this paper uses a newly introduced non-parametric approach called lower upper bound estimation (LUBE) to build the PIs since the forecasting errors are unable to be modelled properly by applying distribution probability functions. In the present proposed LUBE method, a PI combination-based fuzzy framework is used to overcome the performance instability of neutral networks (NNs) used in LUBE. In comparison to other methods, this formulation more suitably has satisfied the PI coverage and PI normalised average width (PINAW). Since this non-linear problem has a high complexity, a new heuristic-based optimisation algorithm comprising a novel modification is introduced to solve the aforesaid problems. Based on data sets taken from a wind farm in Australia, the feasibility and satisfying performance of the suggested method have been investigated.
Park, J-H; Hong, J J; Park, J H
2003-01-01
Mice (n=34) were inoculated orally with a gastric homogenate from a pig infected with tightly coiled spiral bacteria (TCSB). In mice killed in pairs at 16 intervals up to 108 weeks post-inoculation (pi), TCSB were invariably found, mainly in the mucosal surface, gastric pits, intercellular spaces, cytoplasm of surface epithelial cells, and lumina of gastric glands. Histopathologically, infiltration of lymphocytes and plasma cells was seen from 8 weeks pi onwards, gradually increasing as infection progressed. From 64 weeks pi onwards, the formation of large follicles was observed in the lamina propria and submucosa, together with severe necrosis of surface epithelial cells. Glandular epithelial cells in the fundic mucosa were markedly dysplastic and intruded through the basement membrane into the submucosal layer. Common antigenicity between TCSB and Helicobacter pylori was demonstrated by Western blotting, ELISA, and immunohistochemistry. The sequence of the 16S rDNA fragment of 374 bp showed 100% homology with the 16S rRNA gene of "Candidatus Helicobacter suis". Experimental infection of the gastric mucosa of mice with TCSB was closely associated with chronic gastritis and dysplastic lesions.
Johnen, Vanessa M; Neubert, Franz-Xaver; Buch, Ethan R; Verhagen, Lennart; O'Reilly, Jill X; Mars, Rogier B; Rushworth, Matthew F S
2015-01-01
Correlations in brain activity between two areas (functional connectivity) have been shown to relate to their underlying structural connections. We examine the possibility that functional connectivity also reflects short-term changes in synaptic efficacy. We demonstrate that paired transcranial magnetic stimulation (TMS) near ventral premotor cortex (PMv) and primary motor cortex (M1) with a short 8-ms inter-pulse interval evoking synchronous pre- and post-synaptic activity and which strengthens interregional connectivity between the two areas in a pattern consistent with Hebbian plasticity, leads to increased functional connectivity between PMv and M1 as measured with functional magnetic resonance imaging (fMRI). Moreover, we show that strengthening connectivity between these nodes has effects on a wider network of areas, such as decreasing coupling in a parallel motor programming stream. A control experiment revealed that identical TMS pulses at identical frequencies caused no change in fMRI-measured functional connectivity when the inter-pulse-interval was too long for Hebbian-like plasticity. DOI: http://dx.doi.org/10.7554/eLife.04585.001 PMID:25664941
Dehkordi, Parastoo; Garde, Ainara; Karlen, Walter; Wensley, David; Ansermino, J Mark; Dumont, Guy A
2013-01-01
Heart Rate Variability (HRV), the variation of time intervals between heartbeats, is one of the most promising and widely used quantitative markers of autonomic activity. Traditionally, HRV is measured as the series of instantaneous cycle intervals obtained from the electrocardiogram (ECG). In this study, we investigated the estimation of variation in heart rate from a photoplethysmography (PPG) signal, called pulse rate variability (PRV), and assessed its accuracy as an estimate of HRV in children with and without sleep disordered breathing (SDB). We recorded raw PPGs from 72 children using the Phone Oximeter, an oximeter connected to a mobile phone. Full polysomnography including ECG was simultaneously recorded for each subject. We used correlation and Bland-Altman analysis for comparing the parameters of HRV and PRV between two groups of children. Significant correlation (r > 0.90, p < 0.05) and close agreement were found between HRV and PRV for mean intervals, standard deviation of intervals (SDNN) and the root-mean square of the difference of successive intervals (RMSSD). However Bland-Altman analysis showed a large divergence for LF/HF ratio parameter. In addition, children with SDB had depressed SDNN and RMSSD and elevated LF/HF in comparison to children without SDB. In conclusion, PRV provides the accurate estimate of HRV in time domain analysis but does not reflect precise estimation for parameters in frequency domain.
Automatic frequency control for FM transmitter
NASA Technical Reports Server (NTRS)
Honnell, M. A. (Inventor)
1974-01-01
An automatic frequency control circuit for an FM television transmitter is described. The frequency of the transmitter is sampled during what is termed the back porch portion of the horizontal synchronizing pulse which occurs during the retrace interval, the frequency sample compared with the frequency of a reference oscillator, and a correction applied to the frequency of the transmitter during this portion of the retrace interval.
Wheeler, Alyssa R.; Fulton, Kara A.; Gaudette, Jason E.; Simmons, Ryan A.; Matsuo, Ikuo; Simmons, James A.
2016-01-01
Big brown bats (Eptesicus fuscus) emit trains of brief, wideband frequency-modulated (FM) echolocation sounds and use echoes of these sounds to orient, find insects, and guide flight through vegetation. They are observed to emit sounds that alternate between short and long inter-pulse intervals (IPIs), forming sonar sound groups. The occurrence of these strobe groups has been linked to flight in cluttered acoustic environments, but how exactly bats use sonar sound groups to orient and navigate is still a mystery. Here, the production of sound groups during clutter navigation was examined. Controlled flight experiments were conducted where the proximity of the nearest obstacles was systematically decreased while the extended scene was kept constant. Four bats flew along a corridor of varying widths (100, 70, and 40 cm) bounded by rows of vertically hanging plastic chains while in-flight echolocation calls were recorded. Bats shortened their IPIs for more rapid spatial sampling and also grouped their sounds more tightly when flying in narrower corridors. Bats emitted echolocation calls with progressively shorter IPIs over the course of a flight, and began their flights by emitting shorter starting IPI calls when clutter was denser. The percentage of sound groups containing 3 or more calls increased with increasing clutter proximity. Moreover, IPI sequences having internal structure become more pronounced when corridor width narrows. A novel metric for analyzing the temporal organization of sound sequences was developed, and the results indicate that the time interval between echolocation calls depends heavily on the preceding time interval. The occurrence of specific IPI patterns were dependent upon clutter, which suggests that sonar sound grouping may be an adaptive strategy for coping with pulse-echo ambiguity in cluttered surroundings. PMID:27445723
Frohman, L A; Downs, T R; Clarke, I J; Thomas, G B
1990-01-01
To elucidate the role of growth hormone (GH)-releasing hormone (GRH) and somatostatin (SRIH) in the regulation of the growth hormone (GH) secretory pattern, we collected portal blood from five unanesthetized ovariectomized ewes for repeated measurements of GRH and SRIH simultaneous with those of peripheral GH. Hormones were measured at 10-min intervals for 5.5 h and their interrelationships analyzed. Mean portal GRH was 20.4 +/- 6.7 (SD) pg/ml and the estimated overall secretion rate was 13 pg/min. GRH secretion was pulsatile with peaks of 25-40 pg/ml and a mean pulse interval of 71 min. Mean portal SRIH was 72 +/- 33 pg/ml and the estimated overall secretion rate was 32 pg/min. SRIH secretion was also pulsatile with peaks of 65-160 pg/ml and a mean pulse interval of 54 min. The GH pulse interval was 62 min. A significant association was present between GRH and GH secretory peaks though not between GRH and SRIH or SRIH and GH. Insulin hypoglycemia resulted in a rapid and brief stimulation of SRIH secretion followed by a decline in GH levels. No effect was observed on GRH secretion until 90 min, when a slight increase occurred. The results suggest (a) the presence of an independent neural rhythmicity of GRH and SRIH secretion with a primary role of GRH in determining pulsatile GRH secretion, and (b) that the inhibitory effects of insulin hypoglycemia on GH in this species are attributable to a combination of enhanced SRIH secretion and possibly other factors, though without significant inhibition of GRH. PMID:1973173
NASA Astrophysics Data System (ADS)
Chen, Liang-Kuang; Wu, Tung-Hsin; Yang, Ching-Ching; Tsai, Chia-Jung; Lee, Jason J. S.
2010-07-01
The aim of this study is to assess radiation dose and the corresponding image quality from suggested CT protocols which depends on different mean heart rate and high heart rate variability by using 256-slice CT. Fifty consecutive patients referred for a cardiac CT examination were included in this study. All coronary computed tomographic angiography (CCTA) examinations were performed on a 256-slice CT scanner with one of five different protocols: retrospective ECG-gating (RGH) with full dose exposure in all R-R intervals (protocol A), RGH of 30-80% pulsing window with tube current modulation (B), RGH of 78±5% pulsing window with tube current modulation (C), prospective ECG-triggering (PGT) of 78% R-R interval with 5% padding window (D) and PGT of 78% R-R interval without padding window (E). Radiation dose parameters and image quality scoring were determined and compared. In this study, no significant differences were found in comparison on image quality of the five different protocols. Protocol A obtained the highest radiation dose comparing with those of protocols B, C, D and E by a factor of 1.6, 2.4, 2.5 and 4.3, respectively ( p<0.001), which were ranged between 2.7 and 11.8 mSv. The PGT could significantly reduce radiation dose delivered to patients, as compared to the RGH. However, the use of PGT has limitations and is only good in assessing cases with lower mean heart rate and stable heart rate variability. With higher mean heart rate and high heart rate variability circumstances, the RGH within 30-80% of R-R interval pulsing window is suggested as a feasible technique for assessing diagnostic performance.
Azim, Hamdy A.; Kassem, Loay; Treilleux, Isabelle; Wang, Qing; El Enein, Mona Abu; Anis, Shady E.; Bachelot, Thomas
2016-01-01
BACKGROUND: The PI3K/AKT/mTOR pathway alterations have been shown to play significant roles in the development, progression, and metastatic spread of breast cancer. Furthermore, they have been implicated in the process of drug resistance, especially endocrinal therapies. In this study, we aimed to define the correlation between the PI3K mutations and the expression of the phosphorylated forms of different downstream molecules in women with estrogen receptor (ER)–positive, human epidermal growth factor receptor 2–negative (luminal) early breast cancer treated at Cairo university hospitals. METHODS: Next-generation sequencing was used to detect mutations in the PIK3CA hotspots (in exons 9 and 20). Immunohistochemistry was performed on tissue microarray blocks prepared from samples of 35 Egyptian luminal breast cancer patients in the pathology department of Centre Léon Bérard (CLB). The intensity and the percentage of stained tumor cells were integrated to define high versus low biomarker expression. The cytoplasmic and nuclear stainings were graded separately. Patients were followed for a median of 4.7 years (2.1 to 6.9 years). Correlation was done between PI3K mutations and the immunohistochemistry expression of pAKT, LKB1, p4EBP1, and pS6 ribosomal protein (pS6RP) with the clinicopathologic features and disease free survival (DFS) of the patients. RESULTS: Median age at diagnosis was 51.3 years (range, 25 to 82 years). Tumors were larger than 20 mm in 79.2% of the cases, whereas 57.9% had axillary lymph node deposits. Only 12.3% of the patients had SBR grade I tumors, 50.8% had grade II, and 36.8% had grade III. ERs were negative in 6 patients (17%) after pathology review. Thirty-two cases were assessable for LKB1 and pAKT, 33 for p4EBP1 and pS6RP, and 24 for PI3K mutations. Nuclear LKB1, cytoplasmic LKB1, nuclear pAKT, cytoplasmic pAKT, nuclear p4EBP1, and cytoplasmic pS6RP expression was high in 65.6%, 62.5%, 62.5%, 68.8%, 42.4%, and 57.6%, respectively. PIK3CA mutations were found in 7 patients (29.2%). PI3K mutations were correlated with nuclear localization of pAKT (i.e., decreased cytoplasmic pAKT, P = .04; and increased nuclear pAKT, P = .10). There was a tendency toward an inverse correlation between PI3K mutations and the expression of pS6RP (P = .10) and p4EBP1 (P = .19). Nuclear LKB1 expression was a marker of good prognosis. It was associated with smaller tumors (P = .05), more ER (P = .08) and progesteron receptor (PgR) positivity (P = .002). In the Kaplan Meier (KM) model, patients with high nuclear LKB1 had longer DFS (hazard ratio = 0.36; 95% confidence interval, 0.15-1.10; P = .08). Nuclear pAKT high expression also carried a tendency toward longer DFS (hazard ratio = 0.51; 95% confidence interval, 0.11-1.16; P = .13). The expression of p4EBP1, pS6RP, and the PI3K mutational status did not show any prognostic significance in our cohort. CONCLUSION: Among the studied biomarkers, only nuclear expression of LKB1 and pAKT tended to predict better survival in breast cancer patients. PI3K mutation was correlated with the expression of nuclear pAKT but not pS6RP or p4EBP1. PMID:27084427
Enhancement of beam pulse controllability for a single-pulse formation system of a cyclotron.
Kurashima, Satoshi; Miyawaki, Nobumasa; Kashiwagi, Hirotsugu; Okumura, Susumu; Taguchi, Mitsumasa; Fukuda, Mitsuhiro
2015-07-01
The single-pulse formation technique using a beam chopping system consisting of two types of high-voltage beam kickers was improved to enhance the quality and intensity of the single-pulse beam with a pulse interval over 1 μs at the Japan Atomic Energy Agency cyclotron facility. A contamination rate of neighboring beam bunches in the single-pulse beam was reduced to less than 0.1%. Long-term purification of the single pulse beam was guaranteed by the well-controlled magnetic field stabilization system for the cyclotron magnet. Reduction of the multi-turn extraction number for suppressing the neighboring beam bunch contamination was achieved by restriction of a beam phase width and precise optimization of a particle acceleration phase. In addition, the single-pulse beam intensity was increased by a factor of two or more by a combination of two types of beam bunchers using sinusoidal and saw-tooth voltage waveforms. Provision of the high quality intense single-pulse beam contributed to improve the accuracy of experiments for investigation of scintillation light time-profile and for neutron energy measurement by a time-of-flight method.
Enhancement of beam pulse controllability for a single-pulse formation system of a cyclotron
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurashima, Satoshi, E-mail: kurashima.satoshi@jaea.go.jp; Miyawaki, Nobumasa; Kashiwagi, Hirotsugu
The single-pulse formation technique using a beam chopping system consisting of two types of high-voltage beam kickers was improved to enhance the quality and intensity of the single-pulse beam with a pulse interval over 1 μs at the Japan Atomic Energy Agency cyclotron facility. A contamination rate of neighboring beam bunches in the single-pulse beam was reduced to less than 0.1%. Long-term purification of the single pulse beam was guaranteed by the well-controlled magnetic field stabilization system for the cyclotron magnet. Reduction of the multi-turn extraction number for suppressing the neighboring beam bunch contamination was achieved by restriction of amore » beam phase width and precise optimization of a particle acceleration phase. In addition, the single-pulse beam intensity was increased by a factor of two or more by a combination of two types of beam bunchers using sinusoidal and saw-tooth voltage waveforms. Provision of the high quality intense single-pulse beam contributed to improve the accuracy of experiments for investigation of scintillation light time-profile and for neutron energy measurement by a time-of-flight method.« less
Yammine, K; Harvey, A
2013-04-01
We report a systematic review and meta-analysis of published randomised and quasi-randomised trials evaluating the efficacy of pre-operative skin antisepsis and cleansing techniques in reducing foot and ankle skin flora. The post-preparation culture number (Post-PCN) was the primary outcome. The data were evaluated using a modified version of the Cochrane Collaboration’s tool. We identified eight trials (560 participants, 716 feet) that met the inclusion criteria. There was a significant difference in the proportions of Post-PCN between hallux nailfold (HNF) and toe web spaces (TWS) sites: 0.47 vs 0.22, respectively (95% confidence interval (CI) 0.182937 to 0.304097; p < 0.0001). Meta-analyses showed that alcoholic chlorhexidine had better efficacy than alcoholic povidone-iodine (PI) at HNF sites (risk difference 0.19 (95% CI 0.08 to 0.30); p = 0.0005); a two-step intervention using PI scrub and paint (S&P) followed by alcohol showed significantly better efficacy over PI (S&P) alone at TWS sites (risk difference 0.13 (95% CI 0.02 to 0.24); p = 0.0169); and a two-step intervention using chlorhexidine scrub followed by alcohol showed significantly better efficacy over PI (S&P) alone at the combined (HNF with TWS) sites (risk difference 0.27 (95% CI 0.13 to 0.40); p < 0.0001). No significant difference was found between cleansing techniques.
Hall, I E; Bhangoo, R S; Reese, P P; Doshi, M D; Weng, F L; Hong, K; Lin, H; Han, G; Hasz, R D; Goldstein, M J; Schröppel, B; Parikh, C R
2014-04-01
Accurate and reliable assessment tools are needed in transplantation. The objective of this prospective, multi-center study was to determine the associations of the alpha and pi iso-enzymes of glutathione S-transferase (GST), measured from perfusate solution at the start and end (base and post) of kidney allograft machine perfusion, with subsequent delayed graft function (DGF). We also compared GST iso-enzyme perfusate levels from discarded versus transplanted kidneys. A total of 428 kidneys were linked to outcomes as recorded by the United Network of Organ Sharing. DGF, defined as any dialysis in the first week of transplant, occurred in 141 recipients (32%). Alpha- and pi-GST levels significantly increased during machine perfusion. The adjusted relative risks (95% confidence interval) of DGF with each log-unit increase in base and post pi-GST were 1.14 (1.0-1.3) and 1.36 (1.1-1.8), respectively. Alpha-GST was not independently associated with DGF. There were no significant differences in GST values between discarded and transplanted kidneys, though renal resistance was significantly higher in discarded kidneys. We found pi-GST at the end of machine perfusion to be independently associated with DGF. Further studies should elucidate the utility of GST for identifying injured kidneys with regard to organ allocation, discard and recipient management decisions. © Copyright 2014 The American Society of Transplantation and the American Society of Transplant Surgeons.
Survival in Response to Multimodal Therapy in Anaplastic Thyroid Cancer.
Prasongsook, Naiyarat; Kumar, Aditi; Chintakuntlawar, Ashish V; Foote, Robert L; Kasperbauer, Jan; Molina, Julian; Garces, Yolanda; Ma, Daniel; Wittich, Michelle A Neben; Rubin, Joseph; Richardson, Ronald; Morris, John; Hay, Ian; Fatourechi, Vahab; McIver, Bryan; Ryder, Mabel; Thompson, Geoffrey; Grant, Clive; Richards, Melanie; Sebo, Thomas J; Rivera, Michael; Suman, Vera; Jenkins, Sarah M; Smallridge, Robert C; Bible, Keith C
2017-12-01
Historical outcomes in anaplastic thyroid cancer (ATC) have been dismal. To determine whether an initial intensive multimodal therapy (MMT) is associated with improved ATC survival. MMT was offered to all patients with newly diagnosed ATC treated at the Mayo Clinic from 2003 through 2015; MMT vs care with palliative intent (PI) was individualized considering clinical status and patient preferences. Outcomes were retrospectively analyzed by American Joint Committee on Cancer stage and treatments compared with patient cohort data from 1949 through 1999. Forty-eight patients (60% male; median age, 62 years); 18 treated with PI, 30 with MMT. Overall survival (OS) and progression-free survival determined by Kaplan-Meier method. Median OS and 1-year survival for the later cohort were 9 months [95% confidence interval (CI), 4 to 22 months] and 42% (95% CI, 28% to 56%) vs 3 months and 10% for the earlier cohort. Median OS was 21 months compared with 3.9 months in the pooled MMT vs PI groups for the later cohort [hazard ratio (HR), 0.32; P = 0.0006]. Among only patients in the later cohort who had stage IVB disease, median OS was 22.4 vs 4 months (HR, 0.12; 95% CI, 0.03 to 0.44; P = 0.0001), with 68% vs 0% alive at 1 year (MMT vs PI). Among patients with stage IVC cancer, OS did not differ by therapy. MMT appears to convey longer survival in ATC among patients with stage IVA/B disease. Copyright © 2017 Endocrine Society
ELECTRICAL LOAD ANTICIPATOR AND RECORDER
Werme, J.E.
1961-09-01
A system is described in which an indication of the prevailing energy consumption in an electrical power metering system and a projected power demand for one demand in terval is provided at selected increments of time within the demand interval. Each watt-hour meter in the system is provided with an impulse generator that generates two impulses for each revolution of the meter disc. In each demand interval, for example, one half-hour, of the metering system, the total impulses received from all of the meters are continuously totaled for each 5-minute interval and multiplied by a number from 6 to 1 depending upon which 5- minute interval the impulses were received. This value is added to the total pulses received in the intervals preceding the current 5-minute interval within the half-hour demand interval tc thereby provide an indication of the projected power demand every 5 minutes in the demand interval.
Study on transient beam loading compensation for China ADS proton linac injector II
NASA Astrophysics Data System (ADS)
Gao, Zheng; He, Yuan; Wang, Xian-Wu; Chang, Wei; Zhang, Rui-Feng; Zhu, Zheng-Long; Zhang, Sheng-Hu; Chen, Qi; Powers, Tom
2016-05-01
Significant transient beam loading effects were observed during beam commissioning tests of prototype II of the injector for the accelerator driven sub-critical (ADS) system, which took place at the Institute of Modern Physics, Chinese Academy of Sciences, between October and December 2014. During these tests experiments were performed with continuous wave (CW) operation of the cavities with pulsed beam current, and the system was configured to make use of a prototype digital low level radio frequency (LLRF) controller. The system was originally operated in pulsed mode with a simple proportional plus integral and deviation (PID) feedback control algorithm, which was not able to maintain the desired gradient regulation during pulsed 10 mA beam operations. A unique simple transient beam loading compensation method which made use of a combination of proportional and integral (PI) feedback and feedforward control algorithm was implemented in order to significantly reduce the beam induced transient effect in the cavity gradients. The superconducting cavity field variation was reduced to less than 1.7% after turning on this control algorithm. The design and experimental results of this system are presented in this paper. Supported by National Natural Science Foundation of China (91426303, 11525523)
Modeling spiking behavior of neurons with time-dependent Poisson processes.
Shinomoto, S; Tsubo, Y
2001-10-01
Three kinds of interval statistics, as represented by the coefficient of variation, the skewness coefficient, and the correlation coefficient of consecutive intervals, are evaluated for three kinds of time-dependent Poisson processes: pulse regulated, sinusoidally regulated, and doubly stochastic. Among these three processes, the sinusoidally regulated and doubly stochastic Poisson processes, in the case when the spike rate varies slowly compared with the mean interval between spikes, are found to be consistent with the three statistical coefficients exhibited by data recorded from neurons in the prefrontal cortex of monkeys.
Ressox Control of QZSS During Communication Interruption
2009-11-01
Note 1289 (Hewlett-Packard), pp. 60. [5] F. Tappero, A. Dempster, T . Iwata, M. Imae, T . Ikegami , Y. Fukuyama, K. Hagimoto, and A. Iwasaki, 2006...interval, which means an overlapping integral number, set at 2, and t is the time difference measured by TCU. During PI control, applied voltage...Kishimoto, H. Hase, A. Matsumoto, T . Tsuruta, S. Kogure, N. Inaba, M. Sawabe, T . Kawanishi, S. Yoshitomi, and K. Terada, 2007, “QZSS System Design
High-Intensity Interval Cycling Exercise on Wave Reflection and Pulse Wave Velocity.
Kingsley, J Derek; Tai, Yu Lun; Vaughan, Jeremiah A; Mayo, Xián
2017-05-01
Kingsley, JD, Tai, YL, Vaughan, J, and Mayo, X. High-intensity interval cycling exercise on wave reflection and pulse wave velocity. J Strength Cond Res 31(5): 1313-1320, 2017-The purpose of this study was to assess the effects of high-intensity exercise on wave reflection and aortic stiffness. Nine young, healthy men (mean ± SD: age: 22 ± 2 years) participated in the study. The high-intensity interval cycling exercise consisted of 3 sets of Wingate Anaerobic Tests (WATs) with 7.5% of bodyweight as resistance and 2 minutes of rest between each set. Measurements were taken at rest and 1 minute after completion of the WATs. Brachial and aortic blood pressures, as well as wave reflection characteristics, were measured through pulse wave analysis. Aortic stiffness was assessed through carotid-femoral pulse wave velocity (cfPWV). A repeated-measures analysis of variance was used to investigate the effects of the WATs on blood pressure and vascular function across time. There was no change in brachial or aortic systolic pressure from rest to recovery. There was a significant (p ≤ 0.05) decrease in brachial diastolic pressure (rest: 73 ± 6 mm Hg; recovery: 67 ± 9 mm Hg) and aortic diastolic pressure (rest: 75 ± 6 mm Hg; recovery: 70 ± 9 mm Hg) from rest to recovery. In addition, there was no significant change in the augmentation index (rest: 111.4 ± 6.5%; recovery: 109.8 ± 5.8%, p = 0.65) from rest to recovery. However, there was a significant (p ≤ 0.05) increase in the augmentation index normalized at 75 b·min (rest: 3.29 ± 9.82; recovery 21.21 ± 10.87) during recovery compared with rest. There was no change in cfPWV (rest: 5.3 ± 0.8 m·s; recovery: 5.7 ± 0.5m·s; p = 0.09) in response to the WAT. These data demonstrate that high-intensity interval cycling exercise with short rest periods has a nonsignificant effect on vascular function.
Microsecond-scale electric field pulses in cloud lightning discharges
NASA Technical Reports Server (NTRS)
Villanueva, Y.; Rakov, V. A.; Uman, M. A.; Brook, M.
1994-01-01
From wideband electric field records acquired using a 12-bit digitizing system with a 500-ns sampling interval, microsecond-scale pulses in different stages of cloud flashes in Florida and New Mexico are analyzed. Pulse occurrence statistics and waveshape characteristics are presented. The larger pulses tend to occur early in the flash, confirming the results of Bils et al. (1988) and in contrast with the three-stage representation of cloud-discharge electric fields suggested by Kitagawa and Brook (1960). Possible explanations for the discrepancy are discussed. The tendency for the larger pulses to occur early in the cloud flash suggests that they are related to the initial in-cloud channel formation processes and contradicts the common view found in the atmospheric radio-noise literature that the main sources of VLF/LF electromagnetic radiation in cloud flashes are the K processes which occur in the final, or J type, part of the cloud discharge.
Acoustic Injectors for Drop-On-Demand Serial Femtosecond Crystallography.
Roessler, Christian G; Agarwal, Rakhi; Allaire, Marc; Alonso-Mori, Roberto; Andi, Babak; Bachega, José F R; Bommer, Martin; Brewster, Aaron S; Browne, Michael C; Chatterjee, Ruchira; Cho, Eunsun; Cohen, Aina E; Cowan, Matthew; Datwani, Sammy; Davidson, Victor L; Defever, Jim; Eaton, Brent; Ellson, Richard; Feng, Yiping; Ghislain, Lucien P; Glownia, James M; Han, Guangye; Hattne, Johan; Hellmich, Julia; Héroux, Annie; Ibrahim, Mohamed; Kern, Jan; Kuczewski, Anthony; Lemke, Henrik T; Liu, Pinghua; Majlof, Lars; McClintock, William M; Myers, Stuart; Nelsen, Silke; Olechno, Joe; Orville, Allen M; Sauter, Nicholas K; Soares, Alexei S; Soltis, S Michael; Song, Heng; Stearns, Richard G; Tran, Rosalie; Tsai, Yingssu; Uervirojnangkoorn, Monarin; Wilmot, Carrie M; Yachandra, Vittal; Yano, Junko; Yukl, Erik T; Zhu, Diling; Zouni, Athina
2016-04-05
X-ray free-electron lasers (XFELs) provide very intense X-ray pulses suitable for macromolecular crystallography. Each X-ray pulse typically lasts for tens of femtoseconds and the interval between pulses is many orders of magnitude longer. Here we describe two novel acoustic injection systems that use focused sound waves to eject picoliter to nanoliter crystal-containing droplets out of microplates and into the X-ray pulse from which diffraction data are collected. The on-demand droplet delivery is synchronized to the XFEL pulse scheme, resulting in X-ray pulses intersecting up to 88% of the droplets. We tested several types of samples in a range of crystallization conditions, wherein the overall crystal hit ratio (e.g., fraction of images with observable diffraction patterns) is a function of the microcrystal slurry concentration. We report crystal structures from lysozyme, thermolysin, and stachydrine demethylase (Stc2). Additional samples were screened to demonstrate that these methods can be applied to rare samples. Copyright © 2016 Elsevier Ltd. All rights reserved.
Acoustic Injectors for Drop-On-Demand Serial Femtosecond Crystallography
Roessler, Christian G.; Agarwal, Rakhi; Allaire, Marc; ...
2016-03-17
X-ray free-electron lasers (XFELs) provide very intense X-ray pulses suitable for macromolecular crystallography. Each X-ray pulse typically lasts for tens of femtoseconds and the interval between pulses is many orders of magnitude longer. Here we describe two novel acoustic injection systems that use focused sound waves to eject picoliter to nanoliter crystal-containing droplets out of microplates and into the X-ray pulse from which diffraction data are collected. The on-demand droplet delivery is synchronized to the XFEL pulse scheme, resulting in X-ray pulses intersecting up to 88% of the droplets. We tested several types of samples in a range of crystallizationmore » conditions, wherein the overall crystal hit ratio (e.g., fraction of images with observable diffraction patterns) is a function of the microcrystal slurry concentration. Lastly, we report crystal structures from lysozyme, thermolysin, and stachydrine demethylase (Stc2). In addition, samples were screened to demonstrate that these methods can be applied to rare samples« less
Acoustic Injectors for Drop-On-Demand Serial Femtosecond Crystallography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roessler, Christian G.; Agarwal, Rakhi; Allaire, Marc
X-ray free-electron lasers (XFELs) provide very intense X-ray pulses suitable for macromolecular crystallography. Each X-ray pulse typically lasts for tens of femtoseconds and the interval between pulses is many orders of magnitude longer. Here we describe two novel acoustic injection systems that use focused sound waves to eject picoliter to nanoliter crystal-containing droplets out of microplates and into the X-ray pulse from which diffraction data are collected. The on-demand droplet delivery is synchronized to the XFEL pulse scheme, resulting in X-ray pulses intersecting up to 88% of the droplets. We tested several types of samples in a range of crystallizationmore » conditions, wherein the overall crystal hit ratio (e.g., fraction of images with observable diffraction patterns) is a function of the microcrystal slurry concentration. We report crystal structures from lysozyme, thermolysin, and stachydrine demethylase (Stc2). Additional samples were screened to demonstrate that these methods can be applied to rare samples.« less
Acoustic Injectors for Drop-On-Demand Serial Femtosecond Crystallography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roessler, Christian G.; Agarwal, Rakhi; Allaire, Marc
X-ray free-electron lasers (XFELs) provide very intense X-ray pulses suitable for macromolecular crystallography. Each X-ray pulse typically lasts for tens of femtoseconds and the interval between pulses is many orders of magnitude longer. Here we describe two novel acoustic injection systems that use focused sound waves to eject picoliter to nanoliter crystal-containing droplets out of microplates and into the X-ray pulse from which diffraction data are collected. The on-demand droplet delivery is synchronized to the XFEL pulse scheme, resulting in X-ray pulses intersecting up to 88% of the droplets. We tested several types of samples in a range of crystallizationmore » conditions, wherein the overall crystal hit ratio (e.g., fraction of images with observable diffraction patterns) is a function of the microcrystal slurry concentration. Lastly, we report crystal structures from lysozyme, thermolysin, and stachydrine demethylase (Stc2). In addition, samples were screened to demonstrate that these methods can be applied to rare samples« less
Synchronized flash photolysis and pulse deposition in matrix isolation experiments
NASA Technical Reports Server (NTRS)
Allamandola, Louis J.; Lucas, Donald; Pimentel, George C.
1978-01-01
An apparatus is described which permits flash photolysis of a pulse-deposited gas mixture in a matrix isolation experiment. This technique obviates the limitations of in situ photolysis imposed by the cage effect and by secondary photolysis. The matrix is deposited in pulses at 30-s intervals and photolyzed sequentially by four synchronized flashlamps approximately 1 ms before the pulse strikes the cold surface. Pulsed deposition maintains adequate isolation and causes line narrowing, which enhances spectral sensitivity. The efficacy of flash photolysis combined with pulsed deposition for producing and trapping transient species was demonstrated by infrated detection of CF3 (from photolysis of CF3I/Ar mixtures) and of ClCO (from photolysis of Cl2/CO/Ar mixtures). The apparatus was used to study the photolytic decomposition of gaseous tricarbonylironcyclobutadiene, C4H4Fe(CO)3. The results indicate that the primary photolytic step is not elimination of C4H4, as suggested earlier, but rather of CO.
Microcontroller-based binary integrator for millimeter-wave radar experiments.
Eskelinen, Pekka; Ruoskanen, Jukka; Peltonen, Jouni
2010-05-01
An easily on-site reconfigurable multiple binary integrator for millimeter radar experiments has been constructed of static random access memories, an eight bit microcontroller, and high speed video operational amplifiers. The design uses a raw comparator path and two adjustable m-out-of-n chains in a wired-OR configuration. Standard high speed memories allow the use of pulse widths below 100 ns. For eight pulse repetition intervals it gives a maximum improvement of 6.6 dB for stationary low-level target echoes. The doubled configuration enhances the capability against fluctuating targets. Because of the raw comparator path, also single return pulses of relatively high amplitude are processed.
Hidayat, D.; Chouet, B.; Voight, B.; Dawson, P.; Ratdomopurbo, Antonius
2002-01-01
Very-long-period (VLP) pulses with period of 6-7s, displaying similar waveforms, were identified in 1998 from broadband seismographs around the summit crater. These pulses accompanied most of multiphase (MP) earthquakes, a type of long-period event locally defined at Merapi Volcano. Source mechanisms for several VLP pulses were examined by applying moment tensor inversion to the waveform data. Solutions were consistent with a crack striking ???70?? and dipping ???50?? SW, 100m under the active dome, suggest pressurized gas transport involving accumulation and sudden release of 10-60 m3 of gas in the crack over a 6s interval.
NASA Technical Reports Server (NTRS)
Quilligan, Gerard; DeMonthier, Jeffrey; Suarez, George
2011-01-01
This innovation addresses challenges in lidar imaging, particularly with the detection scheme and the shapes of the detected signals. Ideally, the echoed pulse widths should be extremely narrow to resolve fine detail at high event rates. However, narrow pulses require wideband detection circuitry with increased power dissipation to minimize thermal noise. Filtering is also required to shape each received signal into a form suitable for processing by a constant fraction discriminator (CFD) followed by a time-to-digital converter (TDC). As the intervals between the echoes decrease, the finite bandwidth of the shaping circuits blends the pulses into an analog signal (luminance) with multiple modes, reducing the ability of the CFD to discriminate individual events
Kinetics of transmembrane transport of small molecules into electropermeabilized cells.
Pucihar, Gorazd; Kotnik, Tadej; Miklavcic, Damijan; Teissié, Justin
2008-09-15
The transport of propidium iodide into electropermeabilized Chinese hamster ovary cells was monitored with a photomultiplier tube during and after the electric pulse. The influence of pulse amplitude and duration on the transport kinetics was investigated with time resolutions from 200 ns to 4 ms in intervals from 400 micros to 8 s. The transport became detectable as early as 60 micros after the start of the pulse, continued for tens of seconds after the pulse, and was faster and larger for higher pulse amplitudes and/or longer pulse durations. With fixed pulse parameters, transport into confluent monolayers of cells was slower than transport into suspended cells. Different time courses of fluorescence increase were observed during and at various times after the pulse, reflecting different transport mechanisms and ongoing membrane resealing. The data were compared to theoretical predictions of the Nernst-Planck equation. After a delay of 60 micros, the time course of fluorescence during the pulse was approximately linear, supporting a mainly electrophoretic solution of the Nernst-Planck equation. The time course after the pulse agreed with diffusional solution of the Nernst-Planck equation if the membrane resealing was assumed to consist of three distinct components, with time constants in the range of tens of microseconds, hundreds of microseconds, and tens of seconds, respectively.
NASA Technical Reports Server (NTRS)
Lund, G. F.; Westbrook, R. M.; Fryer, T. B.
1980-01-01
The design details and rationale for a versatile, long-range, long-life telemetry data acquisition system for heart rates and body temperatures at multiple locations from free-ranging animals are presented. The design comprises an implantable transmitter for short to medium range transmission, a receiver retransmitter collar to be worn for long-range transmission, and a signal conditioner interface circuit to assist in signal discrimination and demodulation of receiver or tape-recorded audio outputs. Implanted electrodes are used to obtain an ECG, from which R-wave characteristics are selected to trigger a short RF pulse. Pulses carrying heart rate information are interrupted periodically by a series of pulse interval modulated RF pulses conveying temperature information sensed at desired locations by thermistors. Pulse duration and pulse sequencing are used to discriminate between heart rate and temperature pulses as well as radio frequency interference. The implanted transmitter may be used alone for medium and short-range tracking, or with a receiver-transmitter collar that employs commercial tracking equipment for transmissions of up to 12 km. A system prototype has been tested on a dog.
Active Control of the Forced and Transient Response of a Finite Beam. M.S. Thesis
NASA Technical Reports Server (NTRS)
Post, John Theodore
1989-01-01
When studying structural vibrations resulting from a concentrated source, many structures may be modelled as a finite beam excited by a point source. The theoretical limit on cancelling the resulting beam vibrations by utilizing another point source as an active controller is explored. Three different types of excitation are considered, harmonic, random, and transient. In each case, a cost function is defined and minimized for numerous parameter variations. For the case of harmonic excitation, the cost function is obtained by integrating the mean squared displacement over a region of the beam in which control is desired. A controller is then found to minimize this cost function in the control interval. The control interval and controller location are continuously varied for several frequencies of excitation. The results show that control over the entire beam length is possible only when the excitation frequency is near a resonant frequency of the beam, but control over a subregion may be obtained even between resonant frequencies at the cost of increasing the vibration outside of the control region. For random excitation, the cost function is realized by integrating the expected value of the displacement squared over the interval of the beam in which control is desired. This is shown to yield the identical cost function as obtained by integrating the cost function for harmonic excitation over all excitation frequencies. As a result, it is always possible to reduce the cost function for random excitation whether controlling the entire beam or just a subregion, without ever increasing the vibration outside the region in which control is desired. The last type of excitation considered is a single, transient pulse. A cost function representative of the beam vibration is obtained by integrating the transient displacement squared over a region of the beam and over all time. The form of the controller is chosen a priori as either one or two delayed pulses. Delays constrain the controller to be causal. The best possible control is then examined while varying the region of control and the controller location. It is found that control is always possible using either one or two control pulses. The two pulse controller gives better performance than a single pulse controller, but finding the optimal delay time for the additional controllers increases as the square of the number of control pulses.
Power supply and pulsing strategies for the future linear colliders
NASA Astrophysics Data System (ADS)
Brogna, A. S.; Göttlicher, P.; Weber, M.
2012-02-01
The concept of the power delivery systems of the future linear colliders exploits the pulsed bunch structure of the beam in order to minimize the average current in the cables and the electronics and thus to reduce the material budget and heat dissipation. Although modern integrated circuit technologies are already available to design a low-power system, the concepts on how to pulse the front-end electronics and further reduce the power are not yet well understood. We propose a possible implementation of a power pulsing system based on a DC/DC converter and we choose the Analog Hadron Calorimeter as a specific example. The model features large switching currents of electronic modules in short time intervals to stimulate the inductive components along the cables and interconnections.
Assessing and minimizing contamination in time of flight based validation data
NASA Astrophysics Data System (ADS)
Lennox, Kristin P.; Rosenfield, Paul; Blair, Brenton; Kaplan, Alan; Ruz, Jaime; Glenn, Andrew; Wurtz, Ronald
2017-10-01
Time of flight experiments are the gold standard method for generating labeled training and testing data for the neutron/gamma pulse shape discrimination problem. As the popularity of supervised classification methods increases in this field, there will also be increasing reliance on time of flight data for algorithm development and evaluation. However, time of flight experiments are subject to various sources of contamination that lead to neutron and gamma pulses being mislabeled. Such labeling errors have a detrimental effect on classification algorithm training and testing, and should therefore be minimized. This paper presents a method for identifying minimally contaminated data sets from time of flight experiments and estimating the residual contamination rate. This method leverages statistical models describing neutron and gamma travel time distributions and is easily implemented using existing statistical software. The method produces a set of optimal intervals that balance the trade-off between interval size and nuisance particle contamination, and its use is demonstrated on a time of flight data set for Cf-252. The particular properties of the optimal intervals for the demonstration data are explored in detail.
Lee, Jae Hyup; Choe, Senyon; Han, Shihuan
2018-02-01
This study was performed for the purpose to evaluate the effect of activin A/BMP-2 chimera (AB204) on cardiovascular system and toxicological effect in beagle dogs. When administered AB204 at the dose of 0.32 mg/kg via intravenous injection in beagle dogs, there were no changes in systolic, diastolic and mean blood pressure as well as in pulse rate, in addition that there were no differences in ORS complex, PR interval, R-R interval, QT interval and QTcV interval on the electrocardiography. Also, when administered AB204 at the doses of 0.25 and 0.5 mg/kg/day via repetitive intravenous injection for 2 weeks, it did not cause any significant changes in general symptoms, weight, food intake, ophthalmologic abnormality, urine, hematology, serum biochemistry, organ weight and autopsy values. Therefore, AB204 did not affect cardiovascular functions including blood pressure, pulse rate and ECG, when administered at the dose of ≤0.32 mg/kg via single intravenous injection in male beagle dogs. When it was administered at the dose of 0.5 mg/kg repetitive intravenous injection for 2 weeks, it did not show any toxicity.
Disassembly time of deuterium-cluster-fusion plasma irradiated by an intense laser pulse.
Bang, W
2015-07-01
Energetic deuterium ions from large deuterium clusters (>10nm diameter) irradiated by an intense laser pulse (>10(16)W/cm(2)) produce DD fusion neutrons for a time interval determined by the geometry of the resulting fusion plasma. We present an analytical solution of this time interval, the plasma disassembly time, for deuterium plasmas that are cylindrical in shape. Assuming a symmetrically expanding deuterium plasma, we calculate the expected fusion neutron yield and compare with an independent calculation of the yield using the concept of a finite confinement time at a fixed plasma density. The calculated neutron yields agree quantitatively with the available experimental data. Our one-dimensional simulations indicate that one could expect a tenfold increase in total neutron yield by magnetically confining a 10-keV deuterium fusion plasma for 10ns.
Architecture for a 1-GHz Digital RADAR
NASA Technical Reports Server (NTRS)
Mallik, Udayan
2011-01-01
An architecture for a Direct RF-digitization Type Digital Mode RADAR was developed at GSFC in 2008. Two variations of a basic architecture were developed for use on RADAR imaging missions using aircraft and spacecraft. Both systems can operate with a pulse repetition rate up to 10 MHz with 8 received RF samples per pulse repetition interval, or at up to 19 kHz with 4K received RF samples per pulse repetition interval. The first design describes a computer architecture for a Continuous Mode RADAR transceiver with a real-time signal processing and display architecture. The architecture can operate at a high pulse repetition rate without interruption for an infinite amount of time. The second design describes a smaller and less costly burst mode RADAR that can transceive high pulse repetition rate RF signals without interruption for up to 37 seconds. The burst-mode RADAR was designed to operate on an off-line signal processing paradigm. The temporal distribution of RF samples acquired and reported to the RADAR processor remains uniform and free of distortion in both proposed architectures. The majority of the RADAR's electronics is implemented in digital CMOS (complementary metal oxide semiconductor), and analog circuits are restricted to signal amplification operations and analog to digital conversion. An implementation of the proposed systems will create a 1-GHz, Direct RF-digitization Type, L-Band Digital RADAR--the highest band achievable for Nyquist Rate, Direct RF-digitization Systems that do not implement an electronic IF downsample stage (after the receiver signal amplification stage), using commercially available off-the-shelf integrated circuits.
Laser pulse stretcher method and apparatus
Hawkins, Jon K.; Williams, William A.
1990-01-01
The output of an oscillator stage of a laser system is monitored by a photocell which is coupled to a feedback section to control a Pockels Cell and change the light output of the oscillator stage. A synchronizing pulse is generated in timed relation to the initiation of operation of the oscillator stage and is applied to a forward feed section which cooperates with the feedback section to maintain the light output constant for an extended time interval.
Quantum memory for squeezed light.
Appel, Jürgen; Figueroa, Eden; Korystov, Dmitry; Lobino, M; Lvovsky, A I
2008-03-07
We produce a 600-ns pulse of 1.86-dB squeezed vacuum at 795 nm in an optical parametric amplifier and store it in a rubidium vapor cell for 1 mus using electromagnetically induced transparency. The recovered pulse, analyzed using time-domain homodyne tomography, exhibits up to 0.21+/-0.04 dB of squeezing. We identify the factors leading to the degradation of squeezing and investigate the phase evolution of the atomic coherence during the storage interval.
Song pattern recognition in crickets based on a delay-line and coincidence-detector mechanism
Sarmiento-Ponce, Edith Julieta
2017-01-01
Acoustic communication requires filter mechanisms to process and recognize key features of the perceived signals. We analysed such a filter mechanism in field crickets (Gryllus bimaculatus), which communicate with species-specific repetitive patterns of sound pulses and chirps. A delay-line and coincidence-detection mechanism, in which each sound pulse has an impact on the processing of the following pulse, is implicated to underlie the recognition of the species-specific pulse pattern. Based on this concept, we hypothesized that altering the duration of a single pulse or inter-pulse interval in three-pulse chirps will lead to different behavioural responses. Phonotaxis was tested in female crickets walking on a trackball exposed to different sound paradigms. Changing the duration of either the first, second or third pulse of the chirps led to three different characteristic tuning curves. Long first pulses decreased the phonotactic response whereas phonotaxis remained strong when the third pulse was long. Chirps with three pulses of increasing duration of 5, 20 and 50 ms elicited phonotaxis, but the chirps were not attractive when played in reverse order. This demonstrates specific, pulse duration-dependent effects while sequences of pulses are processed. The data are in agreement with a mechanism in which processing of a sound pulse has an effect on the processing of the subsequent pulse, as outlined in the flow of activity in a delay-line and coincidence-detector circuit. Additionally our data reveal a substantial increase in the gain of phonotaxis, when the number of pulses of a chirp is increased from two to three. PMID:28539524
Song pattern recognition in crickets based on a delay-line and coincidence-detector mechanism.
Hedwig, Berthold; Sarmiento-Ponce, Edith Julieta
2017-05-31
Acoustic communication requires filter mechanisms to process and recognize key features of the perceived signals. We analysed such a filter mechanism in field crickets ( Gryllus bimaculatus ), which communicate with species-specific repetitive patterns of sound pulses and chirps. A delay-line and coincidence-detection mechanism, in which each sound pulse has an impact on the processing of the following pulse, is implicated to underlie the recognition of the species-specific pulse pattern. Based on this concept, we hypothesized that altering the duration of a single pulse or inter-pulse interval in three-pulse chirps will lead to different behavioural responses. Phonotaxis was tested in female crickets walking on a trackball exposed to different sound paradigms. Changing the duration of either the first, second or third pulse of the chirps led to three different characteristic tuning curves. Long first pulses decreased the phonotactic response whereas phonotaxis remained strong when the third pulse was long. Chirps with three pulses of increasing duration of 5, 20 and 50 ms elicited phonotaxis, but the chirps were not attractive when played in reverse order. This demonstrates specific, pulse duration-dependent effects while sequences of pulses are processed. The data are in agreement with a mechanism in which processing of a sound pulse has an effect on the processing of the subsequent pulse, as outlined in the flow of activity in a delay-line and coincidence-detector circuit. Additionally our data reveal a substantial increase in the gain of phonotaxis, when the number of pulses of a chirp is increased from two to three. © 2017 The Authors.
Wang, Yan; Zhang, Jin; Qain, Yuesheng; Tang, Xiaofeng; Ling, Huawei; Chen, Kemin; Li, Yan; Gao, Pingjin; Zhu, Dingliang
2016-08-01
Intracranial arterial stenosis is a common cause of ischemic stroke in Asians. We therefore sought to explore the relationship of brachial-ankle pulse wave velocity and intracranial arterial stenosis in 834 stroke-free hypertensive patients. Intracranial arterial stenosis was evaluated through computerized tomographic angiography. Brachial-ankle pulse wave velocity was measured by an automated cuff device. The top decile of brachial-ankle pulse wave velocity was significantly associated with intracranial arterial stenosis (P = .027, odds ratio = 1.82; 95% confidence interval: 1.07-3.10). The patients with the top decile of brachial-ankle pulse wave velocity showed 56% higher risk for the presence of intracranial arterial stenosis to the whole population, which was more significant in patients younger than 65 years old. We also found that brachial-ankle pulse wave velocity related to both intracranial arterial stenosis and homocysteine. Our study showed the association of brachial-ankle pulse wave velocity with asymptomatic intracranial arterial stenosis in hypertension patients, especially in relative younger subjects. Brachial-ankle pulse wave velocity might be a relatively simple and repeatable measurement to detect hypertension patients in high risk of intracranial arterial stenosis. Copyright © 2016. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Li, Xuebao; Cui, Xiang; Lu, Tiebing; Ma, Wenzuo; Bian, Xingming; Wang, Donglai; Hiziroglu, Huseyin
2016-03-01
The corona-generated audible noise (AN) has become one of decisive factors in the design of high voltage direct current (HVDC) transmission lines. The AN from transmission lines can be attributed to sound pressure pulses which are generated by the multiple corona sources formed on the conductor, i.e., transmission lines. In this paper, a detailed time-domain characteristics of the sound pressure pulses, which are generated by the DC corona discharges formed over the surfaces of a stranded conductors, are investigated systematically in a laboratory settings using a corona cage structure. The amplitude of sound pressure pulse and its time intervals are extracted by observing a direct correlation between corona current pulses and corona-generated sound pressure pulses. Based on the statistical characteristics, a stochastic model is presented for simulating the sound pressure pulses due to DC corona discharges occurring on conductors. The proposed stochastic model is validated by comparing the calculated and measured A-weighted sound pressure level (SPL). The proposed model is then used to analyze the influence of the pulse amplitudes and pulse rate on the SPL. Furthermore, a mathematical relationship is found between the SPL and conductor diameter, electric field, and radial distance.
ELABELA Is an Endogenous Growth Factor that Sustains hESC Self-Renewal via the PI3K/AKT Pathway.
Ho, Lena; Tan, Shawn Y X; Wee, Sheena; Wu, Yixuan; Tan, Sam J C; Ramakrishna, Navin B; Chng, Serene C; Nama, Srikanth; Szczerbinska, Iwona; Sczerbinska, Iwona; Chan, Yun-Shen; Avery, Stuart; Tsuneyoshi, Norihiro; Ng, Huck Hui; Gunaratne, Jayantha; Dunn, N Ray; Reversade, Bruno
2015-10-01
ELABELA (ELA) is a peptide hormone required for heart development that signals via the Apelin Receptor (APLNR, APJ). ELA is also abundantly secreted by human embryonic stem cells (hESCs), which do not express APLNR. Here we show that ELA signals in a paracrine fashion in hESCs to maintain self-renewal. ELA inhibition by CRISPR/Cas9-mediated deletion, shRNA, or neutralizing antibodies causes reduced hESC growth, cell death, and loss of pluripotency. Global phosphoproteomic and transcriptomic analyses of ELA-pulsed hESCs show that it activates PI3K/AKT/mTORC1 signaling required for cell survival. ELA promotes hESC cell-cycle progression and protein translation and blocks stress-induced apoptosis. INSULIN and ELA have partially overlapping functions in hESC medium, but only ELA can potentiate the TGFβ pathway to prime hESCs toward the endoderm lineage. We propose that ELA, acting through an alternate cell-surface receptor, is an endogenous secreted growth factor in human embryos and hESCs that promotes growth and pluripotency. Copyright © 2015 Elsevier Inc. All rights reserved.
Mátrai, Péter; Hegyi, Péter; Szabó, Imre; Vincze, Áron; Balaskó, Márta; Mosdósi, Bernadett; Sarlós, Patrícia; Simon, Mária; Márta, Katalin; Mikó, Alexandra; Pécsi, Dániel; Demcsák, Alexandra; Bajor, Judit
2017-01-01
Background and aims Persistent intestinal damage is associated with higher complication rates in celiac disease. We aimed to assess the potential modifiers of mucosal recovery. Materials and methods We screened databases (PubMed, Embase, Cochrane Trials, and Web of Science) for papers on celiac disease. Papers discussing (1) celiac patients (2) follow-up biopsy and (3) mucosal recovery after commencement of a gluten-free diet were included. The primary outcome was to produce a comprehensive analysis of complete mucosal recovery (i.e., Marsh 0 on follow-up). We compared children’s recovery ratios to those of adults. Patients following a strict gluten-free dietary regimen were included in a subgroup. Summary point estimates, 95% confidence intervals (CIs), and 95% predictive intervals (PIs) were calculated. Heterogeneity was tested with I2-statistic. The PROSPERO registration number is CRD42016053482. Results The overall complete mucosal recovery ratio, calculated from 37 observational studies, was 0.36 (CI: 0.28–0.44, PI: -0.12–0.84; I2: 98.4%, p<0.01). Children showed higher complete mucosal recovery ratio than adults (p<0.01): 0.65 (CI: 0.44–0.85, PI: -0.10–1.39; I2: 96.5%, p<0.01) as opposed to 0.24 (CI: 0.15–0.33, PI: -0.19–1.08; I2: 96.3%, p<0.01). In the strict dietary adherence subgroup, complete mucosal recovery ratio was 0.47 (CI: 0.24–0.70, PI: -0.47–1.41; I2: 98.8%, p<0.001). On meta-regression, diagnostic villous atrophy (Marsh 3) ratio (-8.97, p<0.01) and male ratio (+6.04, p<0.01) proved to be a significant determinant of complete mucosal recovery, unlike duration of gluten-free diet (+0.01, p = 0.62). The correlation between complete mucosal recovery ratio and age on diagnosis is of borderline significance (-0.03, p = 0.05). Conclusions There is considerable heterogeneity across studies concerning complete mucosal recovery ratios achieved by a gluten-free diet in celiac disease. Several celiac patients fail to achieve complete mucosal recovery even if a strict dietary regimen is followed. Younger age on diagnosis, less severe initial histologic damage and male gender predispose for achieving mucosal recovery. PMID:29095937
Szakács, Zsolt; Mátrai, Péter; Hegyi, Péter; Szabó, Imre; Vincze, Áron; Balaskó, Márta; Mosdósi, Bernadett; Sarlós, Patrícia; Simon, Mária; Márta, Katalin; Mikó, Alexandra; Pécsi, Dániel; Demcsák, Alexandra; Bajor, Judit
2017-01-01
Persistent intestinal damage is associated with higher complication rates in celiac disease. We aimed to assess the potential modifiers of mucosal recovery. We screened databases (PubMed, Embase, Cochrane Trials, and Web of Science) for papers on celiac disease. Papers discussing (1) celiac patients (2) follow-up biopsy and (3) mucosal recovery after commencement of a gluten-free diet were included. The primary outcome was to produce a comprehensive analysis of complete mucosal recovery (i.e., Marsh 0 on follow-up). We compared children's recovery ratios to those of adults. Patients following a strict gluten-free dietary regimen were included in a subgroup. Summary point estimates, 95% confidence intervals (CIs), and 95% predictive intervals (PIs) were calculated. Heterogeneity was tested with I2-statistic. The PROSPERO registration number is CRD42016053482. The overall complete mucosal recovery ratio, calculated from 37 observational studies, was 0.36 (CI: 0.28-0.44, PI: -0.12-0.84; I2: 98.4%, p<0.01). Children showed higher complete mucosal recovery ratio than adults (p<0.01): 0.65 (CI: 0.44-0.85, PI: -0.10-1.39; I2: 96.5%, p<0.01) as opposed to 0.24 (CI: 0.15-0.33, PI: -0.19-1.08; I2: 96.3%, p<0.01). In the strict dietary adherence subgroup, complete mucosal recovery ratio was 0.47 (CI: 0.24-0.70, PI: -0.47-1.41; I2: 98.8%, p<0.001). On meta-regression, diagnostic villous atrophy (Marsh 3) ratio (-8.97, p<0.01) and male ratio (+6.04, p<0.01) proved to be a significant determinant of complete mucosal recovery, unlike duration of gluten-free diet (+0.01, p = 0.62). The correlation between complete mucosal recovery ratio and age on diagnosis is of borderline significance (-0.03, p = 0.05). There is considerable heterogeneity across studies concerning complete mucosal recovery ratios achieved by a gluten-free diet in celiac disease. Several celiac patients fail to achieve complete mucosal recovery even if a strict dietary regimen is followed. Younger age on diagnosis, less severe initial histologic damage and male gender predispose for achieving mucosal recovery.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, Yih -Chung; Xiong, Bo; Bross, David H.
Here, we report on the successful implementation of a high-resolution vacuum ultraviolet (VUV) laser pulsed field ionization-photoion (PFI-PI) detection method for the study of unimolecular dissociation of quantum-state- or energy-selected molecular ions. As a test case, we have determined the 0 K appearance energy (AE 0) for the formation of methylium, CH 3 +, from methane, CH 4, as AE 0 (CH 3 +/CH 4) = 14.32271 ± 0.00013 eV. This value has a significantly smaller error limit, but is otherwise consistent with previous laboratory and/or synchrotron-based studies of this dissociative photoionization onset. Furthermore, the sum of the VUV lasermore » PFI-PI spectra obtained for the parent CH 4 + ion and the fragment CH 3 + ions of methane is found to agree with the earlier VUV pulsed field ionization-photoelectron (VUV-PFI-PE) spectrum of methane, providing unambiguous validation of the previous interpretation that the sharp VUV-PFI-PE step observed at the AE 0 (CH 3 +/CH 4) threshold ensues because of higher PFI detection efficiency for fragment CH 3 + than for parent CH 4 +. This, in turn, is a consequence of the underlying high- n Rydberg dissociation mechanism for the dissociative photoionization of CH 4, which was proposed in previous synchrotron-based VUV-PFI-PE and VUV-PFI-PEPICO studies of CH 4. The present highly accurate 0 K dissociative ionization threshold for CH 4 can be utilized to derive accurate values for the bond dissociation energies of methane and methane cation. For methane, the straightforward application of sequential thermochemistry via the positive ion cycle leads to some ambiguity because of two competing VUV-PFI-PE literature values for the ionization energy of methyl radical. The ambiguity is successfully resolved by applying the Active Thermochemical Tables (ATcT) approach, resulting in D 0 (H-CH 3) = 432.463 ± 0.027 kJ/mol and D 0(H-CH 3 +) = 164.701 ± 0.038 kJ/mol.« less
Chang, Yih -Chung; Xiong, Bo; Bross, David H.; ...
2017-03-27
Here, we report on the successful implementation of a high-resolution vacuum ultraviolet (VUV) laser pulsed field ionization-photoion (PFI-PI) detection method for the study of unimolecular dissociation of quantum-state- or energy-selected molecular ions. As a test case, we have determined the 0 K appearance energy (AE 0) for the formation of methylium, CH 3 +, from methane, CH 4, as AE 0 (CH 3 +/CH 4) = 14.32271 ± 0.00013 eV. This value has a significantly smaller error limit, but is otherwise consistent with previous laboratory and/or synchrotron-based studies of this dissociative photoionization onset. Furthermore, the sum of the VUV lasermore » PFI-PI spectra obtained for the parent CH 4 + ion and the fragment CH 3 + ions of methane is found to agree with the earlier VUV pulsed field ionization-photoelectron (VUV-PFI-PE) spectrum of methane, providing unambiguous validation of the previous interpretation that the sharp VUV-PFI-PE step observed at the AE 0 (CH 3 +/CH 4) threshold ensues because of higher PFI detection efficiency for fragment CH 3 + than for parent CH 4 +. This, in turn, is a consequence of the underlying high- n Rydberg dissociation mechanism for the dissociative photoionization of CH 4, which was proposed in previous synchrotron-based VUV-PFI-PE and VUV-PFI-PEPICO studies of CH 4. The present highly accurate 0 K dissociative ionization threshold for CH 4 can be utilized to derive accurate values for the bond dissociation energies of methane and methane cation. For methane, the straightforward application of sequential thermochemistry via the positive ion cycle leads to some ambiguity because of two competing VUV-PFI-PE literature values for the ionization energy of methyl radical. The ambiguity is successfully resolved by applying the Active Thermochemical Tables (ATcT) approach, resulting in D 0 (H-CH 3) = 432.463 ± 0.027 kJ/mol and D 0(H-CH 3 +) = 164.701 ± 0.038 kJ/mol.« less
Finazzo, Cinzia; Calle, Carlos; Stoll, Stefan; Van Doorslaer, Sabine; Schweiger, Arthur
2006-04-28
The effect of the electron withdrawing or donating character of groups located at the periphery of the phthalocyanine ligand, as well as the influence of polar and nonpolar solvents are of importance for the redox chemistry of metal phthalocyanines. Continuous wave and pulse electron paramagnetic resonance and pulse electron nuclear double resonance spectroscopy at X- and Q-band are applied to investigate the electronic structure of the complexes Cu(II)phthalocyanine (CuPc), copper(II) 2,9,16,23-tetra-tert-butyl-29H,31H-phthalocyanine (CuPc(t)), and copper(II) 1,2,3,4,8,9,10,11,15,16,17,18,22,23,24,25-hexadecafluoro-29H,31H-phthalocyanine (CuPc(F)) in various matrices. Isotope substitutions are used to determine the g values, the copper hyperfine couplings and the hyperfine interactions with the 14N, 1H and 19F nuclei of the macrocycle and the surrounding matrix molecules. Simulations and interpretations of the spectra are shown and discussed, and a qualitative analysis of the data using previous theoretical models is given. Density functional computations facilitate the interpretation of the EPR parameters. The experimental g, copper and nitrogen hyperfine and nuclear quadrupole values are found to be sensitive to changes of the solvent and the structure of the macrocycle. To elucidate the electronic, structural and bonding properties the changes in the g principal values are related to data from UV/Vis spectroscopy and to density functional theory (DFT) computations. The analysis of the EPR data indicates that the in-plane metal-ligand sigma bonding is more covalent for CuPc(t) in toluene than in sulfuric acid. Furthermore, the out-of-plane pi bonding is found to be less covalent in the case of a polar sulfuric acid environment than with nonpolar toluene or H2Pc environment, whereby the covalency of this bonding is increased upon addition of tert-butyl groups. No contribution from in-plane pi bonding is found.
Pradeep, Avani R; Singh, Sonender P; Martande, Santosh S; Naik, Savitha B; N, Priyanka; Kalra, Nitish; Suke, Deepak K
2015-08-01
The aim of the present study was to evaluate the clinical and microbiological effect of systemic levofloxacin (LFX) as an adjunct to scaling and root planing (SRP) in patients with chronic periodontitis (CP). Sixty-five patients with CP were randomly divided into a test (n = 33, SRP and LFX 500 mg, once daily [o.d.]) and a control group (n = 32, SRP and placebo, o.d.). Plaque index (PI), gingival index (GI), percentage of sites with bleeding on probing (%BoP), probing depth (PD), and clinical attachment level (CAL) were recorded at baseline, 10 days, and 1-, 3-, and 6-month intervals. The percentage of sites positive for Aggregatibacter actinomycetemcomitans (A. actinomycetemcomitans), Porphyromonas gingivalis, and Tannerella forsythia were recorded at baseline and at 3 and 6 months. Patients receiving LFX showed statistically-significant improvements in mean PD and CAL. The intergroup difference in PI, GI, and%BoP was not significant at any interval. There was a reduction in the percentage of sites positive for periodontopathic bacteria over the duration of the study in both groups, and a statistically-significant reduction in the number of sites positive for A. actinomycetemcomitans in the LFX group (P < 0.001). Levofloxacin was found to significantly improve the clinical and microbiological parameters in CP individuals. © 2014 Wiley Publishing Asia Pty Ltd.
NASA Astrophysics Data System (ADS)
Peterchev, Angel V.; DʼOstilio, Kevin; Rothwell, John C.; Murphy, David L.
2014-10-01
Objective. This work aims at flexible and practical pulse parameter control in transcranial magnetic stimulation (TMS), which is currently very limited in commercial devices. Approach. We present a third generation controllable pulse parameter device (cTMS3) that uses a novel circuit topology with two energy-storage capacitors. It incorporates several implementation and functionality advantages over conventional TMS devices and other devices with advanced pulse shape control. cTMS3 generates lower internal voltage differences and is implemented with transistors with a lower voltage rating than prior cTMS devices. Main results. cTMS3 provides more flexible pulse shaping since the circuit topology allows four coil-voltage levels during a pulse, including approximately zero voltage. The near-zero coil voltage enables snubbing of the ringing at the end of the pulse without the need for a separate active snubber circuit. cTMS3 can generate powerful rapid pulse sequences (\\lt 10 ms inter pulse interval) by increasing the width of each subsequent pulse and utilizing the large capacitor energy storage, allowing the implementation of paradigms such as paired-pulse and quadripulse TMS with a single pulse generation circuit. cTMS3 can also generate theta (50 Hz) burst stimulation with predominantly unidirectional electric field pulses. The cTMS3 device functionality and output strength are illustrated with electrical output measurements as well as a study of the effect of pulse width and polarity on the active motor threshold in ten healthy volunteers. Significance. The cTMS3 features could extend the utility of TMS as a research, diagnostic, and therapeutic tool.
D’Ostilio, Kevin; Rothwell, John C; Murphy, David L
2014-01-01
Objective This work aims at flexible and practical pulse parameter control in transcranial magnetic stimulation (TMS), which is currently very limited in commercial devices. Approach We present a third generation controllable pulse parameter device (cTMS3) that uses a novel circuit topology with two energy-storage capacitors. It incorporates several implementation and functionality advantages over conventional TMS devices and other devices with advanced pulse shape control. cTMS3 generates lower internal voltage differences and is implemented with transistors with lower voltage rating than prior cTMS devices. Main results cTMS3 provides more flexible pulse shaping since the circuit topology allows four coil-voltage levels during a pulse, including approximately zero voltage. The near-zero coil voltage enables snubbing of the ringing at the end of the pulse without the need for a separate active snubber circuit. cTMS3 can generate powerful rapid pulse sequences (<10 ms inter pulse interval) by increasing the width of each subsequent pulse and utilizing the large capacitor energy storage, allowing the implementation of paradigms such as paired-pulse and quadripulse TMS with a single pulse generation circuit. cTMS3 can also generate theta (50 Hz) burst stimulation with predominantly unidirectional electric field pulses. The cTMS3 device functionality and output strength are illustrated with electrical output measurements as well as a study of the effect of pulse width and polarity on the active motor threshold in 10 healthy volunteers. Significance The cTMS3 features could extend the utility of TMS as a research, diagnostic, and therapeutic tool. PMID:25242286
Ding, Xiaorong; Zhang, Yuanting; Tsang, Hon Ki
2016-02-01
Continuous blood pressure (BP) measurement without a cuff is advantageous for the early detection and prevention of hypertension. The pulse transit time (PTT) method has proven to be promising for continuous cuffless BP measurement. However, the problem of accuracy is one of the most challenging aspects before the large-scale clinical application of this method. Since PTT-based BP estimation relies primarily on the relationship between PTT and BP under certain assumptions, estimation accuracy will be affected by cardiovascular disorders that impair this relationship and by the calibration frequency, which may violate these assumptions. This study sought to examine the impact of heart disease and the calibration interval on the accuracy of PTT-based BP estimation. The accuracy of a PTT-BP algorithm was investigated in 37 healthy subjects and 48 patients with heart disease at different calibration intervals, namely 15 min, 2 weeks, and 1 month after initial calibration. The results showed that the overall accuracy of systolic BP estimation was significantly lower in subjects with heart disease than in healthy subjects, but diastolic BP estimation was more accurate in patients than in healthy subjects. The accuracy of systolic and diastolic BP estimation becomes less reliable with longer calibration intervals. These findings demonstrate that both heart disease and the calibration interval can influence the accuracy of PTT-based BP estimation and should be taken into consideration to improve estimation accuracy.
Auvert, Bertran; Marseille, Elliot; Korenromp, Eline L.; Lloyd-Smith, James; Sitta, Remi; Taljaard, Dirk; Pretorius, Carel; Williams, Brian; Kahn, James G.
2008-01-01
Background Trials in Africa indicate that medical adult male circumcision (MAMC) reduces the risk of HIV by 60%. MAMC may avert 2 to 8 million HIV infections over 20 years in sub-Saharan Africa and cost less than treating those who would have been infected. This paper estimates the financial and human resources required to roll out MAMC and the net savings due to reduced infections. Methods We developed a model which included costing, demography and HIV epidemiology. We used it to investigate 14 countries in sub-Saharan Africa where the prevalence of male circumcision was lower than 80% and HIV prevalence among adults was higher than 5%, in addition to Uganda and the Nyanza province in Kenya. We assumed that the roll-out would take 5 years and lead to an MC prevalence among adult males of 85%. We also assumed that surgery would be done as it was in the trials. We calculated public program cost, number of full-time circumcisers and net costs or savings when adjusting for averted HIV treatments. Costs were in USD, discounted to 2007. 95% percentile intervals (95% PI) were estimated by Monte Carlo simulations. Results In the first 5 years the number of circumcisers needed was 2 282 (95% PI: 2 018 to 2 959), or 0.24 (95% PI: 0.21 to 0.31) per 10 000 adults. In years 6–10, the number of circumcisers needed fell to 513 (95% PI: 452 to 664). The estimated 5-year cost of rolling out MAMC in the public sector was $919 million (95% PI: 726 to 1 245). The cumulative net cost over the first 10 years was $672 million (95% PI: 437 to 1 021) and over 20 years there were net savings of $2.3 billion (95% PI: 1.4 to 3.4). Conclusion A rapid roll-out of MAMC in sub-Saharan Africa requires substantial funding and a high number of circumcisers for the first five years. These investments are justified by MAMC's substantial health benefits and the savings accrued by averting future HIV infections. Lower ongoing costs and continued care savings suggest long-term sustainability. PMID:18682725
Alder, Jay R.; Hostetler, Steven W.
2015-01-01
We apply GENMOM, a coupled atmosphere–ocean climate model, to simulate eight equilibrium time slices at 3000-year intervals for the past 21 000 years forced by changes in Earth–Sun geometry, atmospheric greenhouse gases (GHGs), continental ice sheets, and sea level. Simulated global cooling during the Last Glacial Maximum (LGM) is 3.8 ◦C and the rate of post-glacial warming is in overall agreement with recently published temperature reconstructions. The greatest rate of warming occurs between 15 and 12 ka (2.4 ◦C over land, 0.7 ◦C over oceans, and 1.4 ◦C globally) in response to changes in radiative forcing from the diminished extent of the Northern Hemisphere (NH) ice sheets and increases in GHGs and NH summer insolation. The modeled LGM and 6 ka temperature and precipitation climatologies are generally consistent with proxy reconstructions, the PMIP2 and PMIP3 simulations, and other paleoclimate data–model analyses. The model does not capture the mid-Holocene “thermal maximum” and gradual cooling to preindustrial (PI) global temperature found in the data. Simulated monsoonal precipitation in North Africa peaks between 12 and 9 ka at values ∼ 50 % greater than those of the PI, and Indian monsoonal precipitation peaks at 12 and 9 ka at values ∼ 45 % greater than the PI. GENMOM captures the reconstructed LGM extent of NH and Southern Hemisphere (SH) sea ice. The simulated present-day Antarctica Circumpolar Current (ACC) is ∼ 48 % weaker than the observed (62 versus 119 Sv). The simulated present-day Atlantic Meridional Overturning Circulation (AMOC) of 19.3 ± 1.4 Sv on the Bermuda Rise (33◦ N) is comparable with observed value of 18.7 ± 4.8 Sv. AMOC at 33◦ N is reduced by ∼ 15 % during the LGM, and the largest post-glacial increase (∼ 11 %) occurs during the 15 ka time slice.
Hansen, Nienke L; Kesch, Claudia; Barrett, Tristan; Koo, Brendan; Radtke, Jan P; Bonekamp, David; Schlemmer, Heinz-Peter; Warren, Anne Y; Wieczorek, Kathrin; Hohenfellner, Markus; Kastner, Christof; Hadaschik, Boris
2017-11-01
To evaluate the detection rates of targeted and systematic biopsies in magnetic resonance imaging (MRI) and ultrasound (US) image-fusion transperineal prostate biopsy for patients with previous benign transrectal biopsies in two high-volume centres. A two centre prospective outcome study of 487 patients with previous benign biopsies that underwent transperineal MRI/US fusion-guided targeted and systematic saturation biopsy from 2012 to 2015. Multiparametric MRI (mpMRI) was reported according to Prostate Imaging Reporting and Data System (PI-RADS) Version 1. Detection of Gleason score 7-10 prostate cancer on biopsy was the primary outcome. Positive (PPV) and negative (NPV) predictive values including 95% confidence intervals (95% CIs) were calculated. Detection rates of targeted and systematic biopsies were compared using McNemar's test. The median (interquartile range) PSA level was 9.0 (6.7-13.4) ng/mL. PI-RADS 3-5 mpMRI lesions were reported in 343 (70%) patients and Gleason score 7-10 prostate cancer was detected in 149 (31%). The PPV (95% CI) for detecting Gleason score 7-10 prostate cancer was 0.20 (±0.07) for PI-RADS 3, 0.32 (±0.09) for PI-RADS 4, and 0.70 (±0.08) for PI-RADS 5. The NPV (95% CI) of PI-RADS 1-2 was 0.92 (±0.04) for Gleason score 7-10 and 0.99 (±0.02) for Gleason score ≥4 + 3 cancer. Systematic biopsies alone found 125/138 (91%) Gleason score 7-10 cancers. In patients with suspicious lesions (PI-RADS 4-5) on mpMRI, systematic biopsies would not have detected 12/113 significant prostate cancers (11%), while targeted biopsies alone would have failed to diagnose 10/113 (9%). In equivocal lesions (PI-RADS 3), targeted biopsy alone would not have diagnosed 14/25 (56%) of Gleason score 7-10 cancers, whereas systematic biopsies alone would have missed 1/25 (4%). Combination with PSA density improved the area under the curve of PI-RADS from 0.822 to 0.846. In patients with high probability mpMRI lesions, the highest detection rates of Gleason score 7-10 cancer still required combined targeted and systematic MRI/US image-fusion; however, systematic biopsy alone may be sufficient in patients with equivocal lesions. Repeated prostate biopsies may not be needed at all for patients with a low PSA density and a negative mpMRI read by experienced radiologists. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.
Synthesis of Two-Photon Materials and Two-Photon Liquid Crystals
NASA Technical Reports Server (NTRS)
Subramaniam, Girija
2001-01-01
The duration of the grant was interrupted by two major accidents that the PI met with-- an auto accident in Pasadena, CA during her second summer at JPL which took almost eight months for recovery and a second accident during Fall 2000 that left her in crutches for the entire semester. Further, the time released agreed by the University was not given in a timely fashion. The candidate has been given post-grant expire time off. In spite of all these problems, the PI synthesized a number of new two-photon materials and studied the structure-activity correlation to arrive at the best-optimized structure. The PI's design proved to be one of the best in the sense that these materials has a hitherto unreported two-photon absorption cross section. Many materials based on PI's design was later made by the NASA colleague. This is Phase 1. Phase II of this grant is to orate liquid crystalline nature into this potentially useful materials and is currently in progress. Recent observations of nano- and pico-second response time of homeotropically aligned liquid crystals suggest their inherent potentials to act as laser hardening materials, i.e., as protective devices against short laser pulses. The objective of the current project is to exploit this potential by the synthesis of liquid crystals with high optical nonlinearity and optimizing their performance. The PI is trying structural variations to bring in liquid crystalline nature without losing the high two-photon cross section. Both Phase I and Phase II led to many invited presentations and publications in reputed journals like 'Science' and 'Molecular Crystals'. The list of presentations and reprints are enclosed. Another important and satisfying outcome of this grant is the opportunity that this grant offered to the budding undergraduate scientists to get involved in a visible research of international importance. All the students had a chance to learn a lot during research, had the opportunity to present their work at the National level conferences. They continue to retain their interest in their research and went on to accomplish further laurels.
Shinneman, Douglas J.; Baker, William L.
2009-01-01
Fire is known to structure tree populations, but the role of broad-scale climate variability is less clear. For example, the influence of climatic “teleconnections” (the relationship between oceanic–atmospheric fluctuations and anomalous weather patterns across broad scales) on forest age structure is relatively unexplored. We sampled semiarid piñon–juniper (Pinus edulis–Juniperus osteosperma) woodlands in western Colorado, USA, to test the hypothesis that woodland age structures are shaped by climate, including links to oceanic–atmospheric fluctuations, and by past fires and livestock grazing. Low-severity surface fire was lacking, as fire scars were absent, and did not influence woodland densities, but stand-replacing fires served as long-rotation (>400–600 years), stand-initiating events. Old-growth stands (>300 years old) were found in 75% of plots, consistent with a long fire rotation. Juniper and piñon age structures suggest contrasting responses during the past several centuries to dry and wet episodes linked to the Atlantic Multidecadal Oscillation (AMO) and Pacific Decadal Oscillation (PDO). Juniper density increased slightly during periods of drought, positive (warm) AMO (after ∼10-year lag), and negative (cool) PDO. In contrast, piñon populations may still be recovering from a long, drought-filled period (AD 1620–1820), with pulses of recovery favored during cool AMO, warm PDO, and above-average moisture periods. Analysis of 20th-century tree establishment and instrumental climate data corroborate the long-term relationships between age structure and climate. After Euro–American settlement (AD 1881), livestock grazing reduced understory grasses and forbs, reducing competition with tree seedlings and facilitating climate-induced increases in piñons. Thus tree populations in these woodlands are in flux, affected by drought and wet periods linked to oceanic–atmospheric variability, Euro–American livestock grazing, and long-rotation, high-severity fires. Reductions in livestock grazing levels may aid ecological restoration efforts. However, given long-term fluctuations in tree density and composition, and expected further drought, thinning or burning to reduce tree populations may be misdirected.
SQUID-Detected MRI in the Limit of Zero Static Field
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelso, Nathan Dean
2009-12-14
This thesis describes an implementation of the so-called"zero-field MRI" (ZFMRI) pulse sequence, which allows for imaging in an arbitrarily low B 0 field. The ZFMRI sequence created an effective unidirectional gradient field by using a train of pi pulses to average out the concomitant gradient components during encoding. The signals were acquired using a low-transition temperature dc Superconducting QUantum Interference Device (low-Tc dc SQUID) coupled to a first-order axial gradiometer. The experiments were carried out in a liquid helium dewar which was magnetically shielded with a single-layer mu-metal can around the outside and a superconducting Pb can contained within themore » helium space. We increased the filling factor of the custom-made, double-walled Pyrex insert by placing the liquid alcohol sample, at a temperature of approximately -50 degrees C, at the center of one loop of the superconducting gradiometer, which was immersed in the helium bath.« less
[Association of mineral and bone disorder with increasing PWV in CKD 1-5 patients].
Shiota, Jun; Watanabe, Mitsuhiro
2007-01-01
The association between pulse wave velocity(PWV) and chronic kidney disease mineral and bone disorder(CKD-MBD) was investigated in CKD 1-5 patients without dialysis. Pulse pressure(PP), PWV, serum Cr, non-HDL-cholesterol, Alb, Ca, Pi, calcitriol, intact-PTH and BAP were measured in sixty patients not receiving a phosphate binder or vitamin D. Using the relationship between age and baPWV in healthy subjects, we determined delta baPWV(measured baPWV-calculated baPWV) as an index for the effect of CKD-related factors. delta baPWV was significantly higher in diabetic patients (p < 0.00001). Simple regression analysis revealed that delta baPWV was positively correlated with PP (p < 0.05) and Log(intact-PTH) (p < 0.01), but negatively correlated with Log(estimated GFR) and Log(calcitriol) (p < 0.01). Multiple regression analysis revealed that delta baPWV was significantly associated with PP and calcitriol, or PP and intact-PTH. These results suggest a relationship between PWV and CKD-MBD.
Double diffraction in an atomic gravimeter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malossi, N.; Bodart, Q.; Merlet, S.
2010-01-15
We demonstrate the realization of a scheme for cold-atom gravimetry based on the recently demonstrated use of double-diffraction beam splitters [T. Leveque, A. Gauguet, F. Michaud, F. Pereira Dos Santos, and A. Landragin, Phys. Rev. Lett. 103, 080405 (2009)], where the use of two retro-reflected Raman beams allows symmetric diffraction in +-(Planck constant/2pi)k{sub eff} momenta. Although in principle restricted to the case of zero Doppler shift, for which the two pairs of Raman beams are simultaneously resonant, such diffraction pulses can remain efficient on atoms with nonzero velocity, such as in a gravimeter, when the frequency of one of themore » two Raman laser sources is modulated. Such pulses are used to realize an interferometer insensitive to laser phase noise and some of the dominant systematics. This approach reduces the technical requirements and would allow the realization of a simple atomic gravimeter. A sensitivity of 1.2x10{sup -7}g per shot is demonstrated.« less
Surface-Emitting Distributed Feedback Terahertz Quantum-Cascade Lasers in Metal-Metal Waveguides
NASA Technical Reports Server (NTRS)
Kumar, Sushil; Williams, Benjamin S.; Qin, Qi; Lee, Alan W. M.; Hu, Qing; Reno, John L.
2007-01-01
Single-mode surface-emitting distributed feedback terahertz quantumcascade lasers operating around 2.9 THz are developed in metal-metal waveguides. A combination of techniques including precise control of phase of reflection at the facets, and u e of metal on the sidewalls to eliminate higher-order lateral modes allow robust single-mode operation over a range of approximately 0.35 THz. Single-lobed far-field radiation pattern is obtained using a pi phase-shift in center of the second-order Bragg grating. A grating device operating at 2.93 THz lased up to 149 K in pulsed mode and a temperature tuning of 19 .7 GHz was observed from 5 K to 147 K. The same device lased up to 78 K in continuous-wave (cw) mode emitting more than 6 m W of cw power at 5 K. ln general, maximum temperature of pulsed operation for grating devices was within a few Kelvin of that of multi-mode Fabry-Perot ridge lasers
Páramo, Alejandra; Canosa, André; Le Picard, Sébastien D; Sims, Ian R
2008-10-02
The kinetics of reactions of C2(a(3)Pi(u)) and C2(X(1)Sigma(g)(+)) with various hydrocarbons (CH4, C2H2, C2H4, C2H6, and C3H8) have been studied in a uniform supersonic flow expansion over the temperature range 24-300 K. Rate coefficients have been obtained by using the pulsed laser photolysis-laser induced fluorescence technique, where both radicals were produced at the same time but detected separately. The reactivity of the triplet state was found to be significantly lower than that of the singlet ground state for all reactants over the whole temperature range of the study. Whereas C2(X(1)Sigma(g)(+)) reacts with a rate coefficient close to the gas kinetic limit with all hydrocarbons studied apart from CH4, C2(a(3)Pi(u)) appears to be more sensitive to the molecular and electronic structure of the reactant partners. The latter reacts at least one order of magnitude faster with unsaturated hydrocarbons than with alkanes, and the rate coefficients increase very significantly with the size of the alkane. Results are briefly discussed in terms of their potential astrophysical impact.
MacPherson, David C.; Nelson, Loren D.; O'Brien, Martin J.
1996-01-01
Apparatus performs a method of generating one or more output laser pulses in a range of 2 to 6 microns. When a plurality of the output laser pulses are generated, a first output pulse has any selected wavelength within the range and a second output pulse is temporally closely spaced relative to the first output pulse and has a chosen wavelength differing from the selected wavelength. An oscillator laser cavity is provided with a tunable oscillator rod capable of generating initial laser pulses within a range of from 750 to 1000 nm, and a tuning element is coupled to the rod. A flashlamp is operable to pump the rod. For two pulse operation, the flashlamp has a given duration. A Q-switch provides the initial laser pulses upon operation of the tuning element and the flashlamp. A Raman device coupled to the rod shifts the wavelength of such initial laser pulse into the range of from 2 to 6 microns to form the output laser pulse having a wavelength within the range. For multiple pulses, a controller causes the Q-switch to provide first and second ones of the initial laser pulses, spaced by a time interval less than the given duration. Also, a selector coupled to the tuning element is operable within such duration to successively select the wavelength of the first output pulse and the chosen wavelength of the second initial pulse. The Raman device is responsive to each of the initial light pulses to generate radiation at first and second Stokes wavelengths, each of said the output laser pulses being radiation at the second Stokes wavelength.
MacPherson, D.C.; Nelson, L.D.; O`Brien, M.J.
1996-12-10
Apparatus performs a method of generating one or more output laser pulses in a range of 2 to 6 microns. When a plurality of the output laser pulses are generated, a first output pulse has any selected wavelength within the range and a second output pulse is temporally closely spaced relative to the first output pulse and has a chosen wavelength differing from the selected wavelength. An oscillator laser cavity is provided with a tunable oscillator rod capable of generating initial laser pulses within a range of from 750 to 1000 nm, and a tuning element is coupled to the rod. A flashlamp is operable to pump the rod. For two pulse operation, the flashlamp has a given duration. A Q-switch provides the initial laser pulses upon operation of the tuning element and the flashlamp. A Raman device coupled to the rod shifts the wavelength of such initial laser pulse into the range of from 2 to 6 microns to form the output laser pulse having a wavelength within the range. For multiple pulses, a controller causes the Q-switch to provide first and second ones of the initial laser pulses, spaced by a time interval less than the given duration. Also, a selector coupled to the tuning element is operable within such duration to successively select the wavelength of the first output pulse and the chosen wavelength of the second initial pulse. The Raman device is responsive to each of the initial light pulses to generate radiation at first and second Stokes wavelengths, each of said the output laser pulses being radiation at the second Stokes wavelength. 30 figs.
Miyazaki, Ryoji; Myougo, Naomi; Mori, Hiroyuki; Akiyama, Yoshinori
2018-01-12
Many proteins form multimeric complexes that play crucial roles in various cellular processes. Studying how proteins are correctly folded and assembled into such complexes in a living cell is important for understanding the physiological roles and the qualitative and quantitative regulation of the complex. However, few methods are suitable for analyzing these rapidly occurring processes. Site-directed in vivo photo-cross-linking is an elegant technique that enables analysis of protein-protein interactions in living cells with high spatial resolution. However, the conventional site-directed in vivo photo-cross-linking method is unsuitable for analyzing dynamic processes. Here, by combining an improved site-directed in vivo photo-cross-linking technique with a pulse-chase approach, we developed a new method that can analyze the folding and assembly of a newly synthesized protein with high spatiotemporal resolution. We demonstrate that this method, named the pulse-chase and in vivo photo-cross-linking experiment (PiXie), enables the kinetic analysis of the formation of an Escherichia coli periplasmic (soluble) protein complex (PhoA). We also used our new technique to investigate assembly/folding processes of two membrane complexes (SecD-SecF in the inner membrane and LptD-LptE in the outer membrane), which provided new insights into the biogenesis of these complexes. Our PiXie method permits analysis of the dynamic behavior of various proteins and enables examination of protein-protein interactions at the level of individual amino acid residues. We anticipate that our new technique will have valuable utility for studies of protein dynamics in many organisms. © 2018 by The American Society for Biochemistry and Molecular Biology, Inc.
Both low and high temperature may increase the risk of stroke mortality
Chen, Renjie; Wang, Cuicui; Meng, Xia; Chen, Honglei; Thach, Thuan Quoc; Wong, Chit-Ming
2013-01-01
Objective: To examine temperature in relation to stroke mortality in a multicity time series study in China. Methods: We obtained data on daily temperature and mortality from 8 large cities in China. We used quasi-Poisson generalized additive models and distributed lag nonlinear models to estimate the accumulative effects of temperature on stroke mortality across multiple days, adjusting for long-term and seasonal trends, day of the week, air pollution, and relative humidity. We applied the Bayesian hierarchical model to pool city-specific effect estimates. Results: Both cold and hot temperatures were associated with increased risk of stroke mortality. The potential effect of cold temperature might last more than 2 weeks. The pooled relative risks of extreme cold (first percentile of temperature) and cold (10th percentile of temperature) temperatures over lags 0–14 days were 1.39 (95% posterior intervals [PI] 1.18–1.64) and 1.11 (95% PI 1.06–1.17), compared with the 25th percentile of temperature. In contrast, the effect of hot temperature was more immediate. The relative risks of stroke mortality over lags 0–3 days were 1.06 (95% PI 1.02–1.10) for extreme hot temperature (99th percentile of temperature) and 1.14 (95% PI 1.05–1.24) for hot temperature (90th percentile of temperature), compared with the 75th percentile of temperature. Conclusions: This study showed that both cold and hot temperatures were associated with increased risk of stroke mortality in China. Our findings may have important implications for stroke prevention in China. PMID:23946311
Both low and high temperature may increase the risk of stroke mortality.
Chen, Renjie; Wang, Cuicui; Meng, Xia; Chen, Honglei; Thach, Thuan Quoc; Wong, Chit-Ming; Kan, Haidong
2013-09-17
To examine temperature in relation to stroke mortality in a multicity time series study in China. We obtained data on daily temperature and mortality from 8 large cities in China. We used quasi-Poisson generalized additive models and distributed lag nonlinear models to estimate the accumulative effects of temperature on stroke mortality across multiple days, adjusting for long-term and seasonal trends, day of the week, air pollution, and relative humidity. We applied the Bayesian hierarchical model to pool city-specific effect estimates. Both cold and hot temperatures were associated with increased risk of stroke mortality. The potential effect of cold temperature might last more than 2 weeks. The pooled relative risks of extreme cold (first percentile of temperature) and cold (10th percentile of temperature) temperatures over lags 0-14 days were 1.39 (95% posterior intervals [PI] 1.18-1.64) and 1.11 (95% PI 1.06-1.17), compared with the 25th percentile of temperature. In contrast, the effect of hot temperature was more immediate. The relative risks of stroke mortality over lags 0-3 days were 1.06 (95% PI 1.02-1.10) for extreme hot temperature (99th percentile of temperature) and 1.14 (95% PI 1.05-1.24) for hot temperature (90th percentile of temperature), compared with the 75th percentile of temperature. This study showed that both cold and hot temperatures were associated with increased risk of stroke mortality in China. Our findings may have important implications for stroke prevention in China.
Itamochi, Hiroaki; Oishi, Tetsuro; Oumi, Nao; Takeuchi, Satoshi; Yoshihara, Kosuke; Mikami, Mikio; Yaegashi, Nobuo; Terao, Yasuhisa; Takehara, Kazuhiro; Ushijima, Kimio; Watari, Hidemichi; Aoki, Daisuke; Kimura, Tadashi; Nakamura, Toshiaki; Yokoyama, Yoshihito; Kigawa, Junzo; Sugiyama, Toru
2017-08-22
Ovarian clear cell carcinoma (OCCC) is mostly resistant to standard chemotherapy that results in poor patient survival. To understand the genetic background of these tumours, we performed whole-genome sequencing of OCCC tumours. Tumour tissue samples and matched blood samples were obtained from 55 Japanese women diagnosed with OCCC. Whole-genome sequencing was performed using the Illumina HiSeq platform according to standard protocols. Alterations to the switch/sucrose non-fermentable (SWI/SNF) subunit, the phosphatidylinositol-3-kinase (PI3K)/Akt signalling pathway, and the receptor tyrosine kinase (RTK)/Ras signalling pathway were found in 51%, 42%, and 29% of OCCC tumours, respectively. The 3-year overall survival (OS) rate for patients with an activated PI3K/Akt signalling pathway was significantly higher than that for those with inactive pathway (91 vs 40%, hazard ratio 0.24 (95% confidence interval (CI) 0.10-0.56), P=0.0010). Similarly, the OS was significantly higher in patients with the activated RTK/Ras signalling pathway than in those with the inactive pathway (91 vs 53%, hazard ratio 0.35 (95% CI 0.13-0.94), P=0.0373). Multivariable analysis revealed that activation of the PI3K/Akt and RTK/Ras signalling pathways was an independent prognostic factor for patients with OCCC. The PI3K/Akt and RTK/Ras signalling pathways may be potential prognostic biomarkers for OCCC patients. Furthermore, our whole-genome sequencing data highlight important pathways for molecular and biological characterisations and potential therapeutic targeting in OCCC.
Techniques for measuring arrival times of pulsar signals 1: DSN observations from 1968 to 1980
NASA Technical Reports Server (NTRS)
Downs, G. S.; Reichley, P. E.
1980-01-01
Techniques used in the ground based observations of pulsars are described, many of them applicable in a navigation scheme. The arrival times of the pulses intercepting Earth are measured at time intervals from a few days to a few months. Low noise, wide band receivers, amplify signals intercepted by 26 m, 34, and 64 m antennas. Digital recordings of total received signal power versus time are cross correlated with the appropriate pulse template.
Shirakashi, S; Goater, C P
2005-02-01
We monitored temporal changes in the magnitude of altered host behaviour in minnows (Pimephales promelas) experimentally infected with metacercariae of a brain-encysting trematode (Ornithodiplostomum ptychocheilus). This parasite develops and then encysts in a region of the brain that mediates the optomotor response (OMR), an innate behaviour that links visual stimuli with motor performance. The OMR of infected and uninfected minnows was evaluated between 0 and 10 weeks post-infection (p.i.), an interval spanning the development period of metacercariae to infectivity in birds. Trials involved monitoring the time an individual minnow spent following a spinning drum that had been painted with alternating black and white stripes. At 2 and 4 weeks p.i., infected minnows followed the drum 40% less often than controls. Differences between controls and infected fish declined thereafter, and were undetectable by 10 weeks p.i. Both control and infected fish habituated equally rapidly to the spinning drum. However, the difference in performance between controls and infected fish was 29% for experienced fish and 48% for fish that had never experienced the drum. Because maximum parasite-induced reduction in OMR coincided with the period of maximum parasite development, the behavioural effects are most likely due to unavoidable pathology in the brain associated with developing larvae.
Chin, Wei-Chien-Benny; Wen, Tzai-Hung; Sabel, Clive E; Wang, I-Hsiang
2017-10-03
A diffusion process can be considered as the movement of linked events through space and time. Therefore, space-time locations of events are key to identify any diffusion process. However, previous clustering analysis methods have focused only on space-time proximity characteristics, neglecting the temporal lag of the movement of events. We argue that the temporal lag between events is a key to understand the process of diffusion movement. Using the temporal lag could help to clarify the types of close relationships. This study aims to develop a data exploration algorithm, namely the TrAcking Progression In Time And Space (TaPiTaS) algorithm, for understanding diffusion processes. Based on the spatial distance and temporal interval between cases, TaPiTaS detects sub-clusters, a group of events that have high probability of having common sources, identifies progression links, the relationships between sub-clusters, and tracks progression chains, the connected components of sub-clusters. Dengue Fever cases data was used as an illustrative case study. The location and temporal range of sub-clusters are presented, along with the progression links. TaPiTaS algorithm contributes a more detailed and in-depth understanding of the development of progression chains, namely the geographic diffusion process.
Bayesian posterior distributions without Markov chains.
Cole, Stephen R; Chu, Haitao; Greenland, Sander; Hamra, Ghassan; Richardson, David B
2012-03-01
Bayesian posterior parameter distributions are often simulated using Markov chain Monte Carlo (MCMC) methods. However, MCMC methods are not always necessary and do not help the uninitiated understand Bayesian inference. As a bridge to understanding Bayesian inference, the authors illustrate a transparent rejection sampling method. In example 1, they illustrate rejection sampling using 36 cases and 198 controls from a case-control study (1976-1983) assessing the relation between residential exposure to magnetic fields and the development of childhood cancer. Results from rejection sampling (odds ratio (OR) = 1.69, 95% posterior interval (PI): 0.57, 5.00) were similar to MCMC results (OR = 1.69, 95% PI: 0.58, 4.95) and approximations from data-augmentation priors (OR = 1.74, 95% PI: 0.60, 5.06). In example 2, the authors apply rejection sampling to a cohort study of 315 human immunodeficiency virus seroconverters (1984-1998) to assess the relation between viral load after infection and 5-year incidence of acquired immunodeficiency syndrome, adjusting for (continuous) age at seroconversion and race. In this more complex example, rejection sampling required a notably longer run time than MCMC sampling but remained feasible and again yielded similar results. The transparency of the proposed approach comes at a price of being less broadly applicable than MCMC.
Weng, Shu-Wen; Chen, Bor-Chyuan; Wang, Yu-Chiao; Liu, Chun-Kai; Chang, Ching-Mao
2016-01-01
Traditional Chinese medicine (TCM) has long been used for patients with psoriasis. This study aimed to investigate TCM usage in patients with psoriasis. We analyzed a cohort of one million individuals representing the 23 million enrollees randomly selected from the National Health Insurance Research Database in Taiwan. We identified 28,510 patients newly diagnosed with psoriasis between 2000 and 2010. Among them, 20,084 (70.4%) patients were TCM users. Patients who were female, younger, white-collar workers and lived in urbanized area tended to be TCM users. The median interval between the initial diagnosis of psoriasis to the first TCM consultation was 12 months. More than half (N = 11,609; 57.8%) of the TCM users received only Chinese herbal medicine. Win-qing-yin and Bai-xian-pi were the most commonly prescribed Chinese herbal formula and single herb, respectively. The core prescription pattern comprised Mu-dan-pi, Wen-qing-yin, Zi-cao, Bai-xian-pi, and Di-fu-zi. Patients preferred TCM than Western medicine consultations when they had metabolic syndrome, hepatitis, rheumatoid arthritis, alopecia areata, Crohn's disease, cancer, depression, fatty liver, chronic airway obstruction, sleep disorder, and allergic rhinitis. In conclusion, TCM use is popular among patients with psoriasis in Taiwan. Future clinical trials to investigate its efficacy are warranted. PMID:27822287
Nikitina, E A; Kaminskaya, A N; Molotkov, D A; Popov, A V; Savvateeva-Popova, E V
2014-01-01
In this paper we present results of a comprehensive analysis of the effect of heat shock at different stages of ontogenesis (adult stage, development of the mushroom bodies and the central complex) on courtship behavior (latency, duration and efficacy of courtship), sound production (pulse interval, dispersion of interpulse interval, the percentage of distorted pulses, the mean duration of the pulse parcels), learning and memory formation compared with the content of isoforms LIMK1 in Drosophila melanogaster male with altered structure of the limk1 gene. The heat shock is shown to affect the behavior parameters and LIMK1 content in analyzed strains of Drosophila. The most pronounced effect of the heat shock was observed at the stage of development of the central complex (CC). Heat shock at CC and adult restores the ability of learning and memory formation in the mutant strain agn(ts3), which normally is not able to learn and form memory. Correlations between changes of content of isoforms LIMK1 and behavioral parameters due to heat shock have not been established.