IEA HPT ANNEX 41 – Cold climate heat pumps: US country report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Groll, Eckhard A.; Baxter, Van D.
In 2012 the International Energy Agency (IEA) Heat Pump Programme (now the Heat Pump Technologies (HPT) program) established Annex 41 to investigate technology solutions to improve performance of heat pumps for cold climates. Four IEA HPT member countries are participating in the Annex – Austria, Canada, Japan, and the United States (U.S.). The principal focus of Annex 41 is on electrically driven air-source heat pumps (ASHP) since that system type has the lowest installation cost of all heat pump alternatives. They also have the most significant performance challenges given their inherent efficiency and capacity issues at cold outdoor temperatures. Availabilitymore » of ASHPs with improved low ambient performance would help bring about a much stronger heat pump market presence in cold areas, which today rely predominantly on fossil fuel furnace heating systems.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baxter, Van D.; Payne, W. Vance; Ling, Jiazhen
The IEA HPT Annex 40 "Heat pump concepts for Nearly Zero Energy Buildings" deals with the application of heat pumps as a core component of the HVAC system for Nearly or Net Zero energy buildings (nZEB). This report covers Task 2 on the system comparison and optimisation and Task 3 dedicated to the development of adapted technologies for nZEB and field monitoring results of heat pump systems in nZEB. In the US team three institutions are involved and have worked on the following projects: The Oak Ridge National Laboratory (ORNL) will summarize development activities through the field demonstration stage formore » several integrated heat pump (IHP) systems electric ground-source (GS-IHP) and air-source (AS-IHP) versions and an engine driven AS-IHP version. The first commercial GS-IHP product was just introduced to the market in December 2012. This work is a contribution to Task 3 of the Annex. The University of Maryland will contribute a software development project to Task 2 of the Annex. The software ThermCom evaluates occupied space thermal comfort conditions accounting for all radiative and convective heat transfer effects as well as local air properties. The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net Zero Energy Residential Test Facility (NZERTF). This residential building was constructed on the NIST campus and officially opened in summer 2013. During the first year, between July 2013 and June 2014, baseline performance of the NZERTF was monitored under a simulated occupancy protocol. The house was equipped with an air-to-air heat pump which included a dedicated dehumidification operating mode. Outdoor conditions, internal loads and modes of heat pump operation were monitored. Field study results with respect to heat pump operation will be reported and recommendations on heat pump optimization for a net zero energy building will be provided. This work is a contribution to Task 3 of the Annex.« less
Summary Article: IEA HPP Annex 36: Quality Installation / Quality Maintenance Sensitivity Studies
Hourahan, Glenn; Domanski, Piotr; Baxter, Van D.
2015-01-30
The outcome from this Annex activity clearly identifies that poorly designed, installed, and/or maintained heat pumps operate inefficiently and waste considerable energy compared to their as-designed potential. Additionally, it is clear that small faults for a given field-observed practice are significant, that some attribute deviations (in various equipment applications and geographical locations) have a larger impact than others, and that multiple faults or deviations have a cumulative impact on heat pump performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Purvis, Edward E.; Teagan, Peter; Little, Arthur D.
1979-04-01
Annex 6, which investigates the possible hydroelectric resources of Egypt, reveals that presently the only existing sites are on the upper Nile at the High and Aswan Dams. There are 8 sites on the Nile where it is practical to add hydroelectric generation and, of these, only 4 are feasible for immediate construction. There are also pumped-storage sites on the Nile and the Red Sea. There is also the Qattara Depression in the Western Desert which can be utilized for conventional, as well as pumped-storage generation, by bringing water from the Mediterranean Sea to the depression by canal or tunnel.more » The options were considered for construction of hydro plants to met the electric load growth of Egypt when other forms of energy supply would be integrated into a comprehensive supply pattern. In Annex 7, the prospective use of nuclear energy to meet Egypt's resources (uranium and thorium) to implement a nuclear energy program, and potential effects of the expanded use of nuclear energy are discussed. Annex 8 discusses solar energy (technology descriptions and impacts, solar thermal power, photovoltaics). Also wind power generation, biomass utilization, desalination, solar air conditioning and refrigeration, and cost of power from diesel engines are discussed. Annex 9 covers geothermal potentials in Egypt, discussing resources with temperatures above 180/sup 0/C; from 150 to 180/sup 0/C; from 100 to 150/sup 0/C; and with temperatures below 100/sup 0/C. Annex 10 discusses the electric power systems in Egypt. The following subjects are covered: existing electric power systems; electrical power facilities under construction or planned for construction by 1985; past and projected growth of electrical energy; distribution; and electrical power system projected from 1985 to 2000. (MCW)« less
Hot conditioning equipment conceptual design report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bradshaw, F.W., Westinghouse Hanford
1996-08-06
This report documents the conceptual design of the Hot Conditioning System Equipment. The Hot conditioning System will consist of two separate designs: the Hot Conditioning System Equipment; and the Hot Conditioning System Annex. The Hot Conditioning System Equipment Design includes the equipment such as ovens, vacuum pumps, inert gas delivery systems, etc.necessary to condition spent nuclear fuel currently in storage in the K Basins of the Hanford Site. The Hot Conditioning System Annex consists of the facility of house the Hot Conditioning System. The Hot Conditioning System will be housed in an annex to the Canister Storage Building. The Hotmore » Conditioning System will consist of pits in the floor which contain ovens in which the spent nuclear will be conditioned prior to interim storage.« less
DEMONSTRATION AND TESTING OF AN EER OPTIMIZER SYSTEM FOR DX AIR-CONDITIONERS
2017-10-07
Performance-Based Maintenance PCS Power Current Sensor PLC Programmable Logic Controller ppm Parts Per Million PSIG Pounds per Square Inch Gauge PVS Power...all utilities and facilities at Patrick AFB, Cape Canaveral AFS, Jonathan Dickinson Military Tracking Annex, Malabar Annex, Ramey Solar Observatory...Cost 8,057 0 Annual O&M Cost 453 1191 Annual FD&D Monitoring 880 ‐ BLCC LIFE CYCLE RESULTS Energy Savings $12,317 O&M Net Savings $493 PV Life Cycle
Report of Programme Commission II (Natural Sciences), Annex - Recommendations.
ERIC Educational Resources Information Center
United Nations Educational, Scientific, and Cultural Organization, Paris (France). General Conference.
As the second part of the report of the Programme Commission II, a summary of recommendations on plans for natural sciences and their applications is presented in this document. Resolutions and budgetary appropriations are two major concerns in the document. The topics are related to the 1973-74 draft program and budget, the 1973-78 draft…
Catargi, B; Breilh, D; Gin, H; Rigalleau, V; Saux, M C; Roger, P; Tabarin, A
2001-06-01
To compare a non-programmable and a programmable insulin external pump using regular insulin on glycemic stability, the risk of severe hypoglycemia and metabolic control in type 1 diabetic patients. Ten type 1 diabetic patients were involved in a randomized, crossover study comparing two periods of 3 months with continuous subcutaneous insulin infusion (CSII) either with a non-programmable insulin pump or a programmable insulin pump. Comparisons were made among mean blood glucose values before and after meals, at bedtime and at 2: 00 a.m.; the risk of severe hypoglycemia assessed by the low blood glucose index (LBGI); and HbA1c. Mean average blood glucose (BG) measurements were significantly lower with the programmable in comparison with the non-programmable insulin pump (respectively 157+/-78 vs. 165+/-79, p=0.034). While postprandial values for BG were not different between the two pumps, the use of the programmable pump resulted in a significant decrease in mean preprandial BG levels (140+/-68 vs. 150+/-73 mg/dl p=0.039). Conversely mean BG level was lower at 2 a.m. with the non-prgrammable pump (125+/-81 vs. 134 +/-93 mg/dl, p=0.02) but with a higher incidence of hypoglycemia. Mean LBGI was comparable with the two pumps (3.1+/-8.6 vs. 2.8+/-6.9, p=0.1). There was a 0.2% decrease in HbA1c during the programmable pump period that did not reach statistical significance (p=0.37). The present study suggests that programmable external insulin pumps, although more complex and more expensive than non-programmable insulin pumps, significantly reduce fasting glycemia during the day without increasing the risk of severe hypoglycemia and are safer during the night.
Impact of Installation Faults on Heat Pump Performance
Hourahan, Glenn; Baxter, Van D.
2015-01-01
Numerous studies and surveys indicate that typically-installed HVAC equipment operate inefficiently and waste considerable energy due to varied installation errors (faults) such as improper refrigerant charge, incorrect airflow, oversized equipment, and leaky ducts. This article summarizes the results of a large United States (U.S.) experimental/analytical study (U.S. contribution to IEA HPP Annex 36) of the impact that different faults have on the performance of an air-source heat pump (ASHP) in a typical U.S. single-family house. It combines building effects, equipment effects, and climate effects in an evaluation of the faults impact on seasonal energy consumption through simulations of the house/ASHPmore » pump system.« less
American Colonial Education Policy and Filipino Labour Migration to the US (1900-1935)
ERIC Educational Resources Information Center
Maca, Mark
2017-01-01
Public mass schooling was the major instrument used by the Americans in the performance of their mission to "civilize" Filipinos. Free primary education was implemented right after the islands' annexation in 1899 and was a critical component (alongside armed force) of the programme for their "pacification". For the elite,…
33 CFR 151.13 - Special areas for Annex I of MARPOL 73/78.
Code of Federal Regulations, 2011 CFR
2011-07-01
... are the Mediterranean Sea area, the Baltic Sea area, the Black Sea area, the Red Sea area, the Gulfs... bilge water does not originate from cargo pump room bilges; (2) The bilge water is not mixed with oil... § 151.13 for the Red Sea area, Gulfs area, Gulf of Aden area, the Oman area of the Arabian Sea, and the...
33 CFR 151.13 - Special areas for Annex I of MARPOL 73/78.
Code of Federal Regulations, 2012 CFR
2012-07-01
... are the Mediterranean Sea area, the Baltic Sea area, the Black Sea area, the Red Sea area, the Gulfs... bilge water does not originate from cargo pump room bilges; (2) The bilge water is not mixed with oil... § 151.13 for the Red Sea area, Gulfs area, Gulf of Aden area, the Oman area of the Arabian Sea, and the...
33 CFR 151.13 - Special areas for Annex I of MARPOL 73/78.
Code of Federal Regulations, 2014 CFR
2014-07-01
... are the Mediterranean Sea area, the Baltic Sea area, the Black Sea area, the Red Sea area, the Gulfs... bilge water does not originate from cargo pump room bilges; (2) The bilge water is not mixed with oil... § 151.13 for the Red Sea area, Gulfs area, Gulf of Aden area, the Oman area of the Arabian Sea, and the...
Analysis of USAREUR Family Housing.
1985-04-01
Standard Installation/Division Personnel System SJA ................ Staff Judge Advocate SPSS ............... Statistical Package for the...for Projecting Family Housing Requirements. a. Attempts to define USAREUR’s programmable family housing deficit Sbased on the FHS have caused anguish ...responses using the Statistical Package for the Social Sciences ( SPSS ) computer program. E-2 ANNEX E RESPONSE TO ESC HOUSING QUESTIONNAIRE Section Page I
In vivo study of flow-rate accuracy of the MedStream Programmable Infusion System.
Venugopalan, Ramakrishna; Ginggen, Alec; Bork, Toralf; Anderson, William; Buffen, Elaine
2011-01-01
Flow-rate accuracy and precision are important parameters to optimizing the efficacy of programmable intrathecal (IT) infusion pump delivery systems. Current programmable IT pumps are accurate within ±14.5% of their programmed infusion rate when assessed under ideal environmental conditions and specific flow-rate settings in vitro. We assessed the flow-rate accuracy of a novel programmable pump system across its entire flow-rate range under typical conditions in sheep (in vivo) and nominal conditions in vitro. The flow-rate accuracy of the MedStream Programmable Pump was assessed in both the in vivo and in vitro settings. In vivo flow-rate accuracy was assessed in 16 sheep at various flow-rates (producing 90 flow intervals) more than 90 ± 3 days. Pumps were then explanted, re-sterilized and in vitro flow-rate accuracy was assessed at 37°C and 1013 mBar (80 flow intervals). In vivo (sheep body temperatures 38.1°C-39.8°C), mean ± SD flow-rate error was 9.32% ± 9.27% and mean ± SD leak-rate was 0.028 ± 0.08 mL/day. Following explantation, mean in vitro flow-rate error and leak-rate were -1.05% ± 2.55% and 0.003 ± 0.004 mL/day (37°C, 1013 mBar), respectively. The MedStream Programmable Pump demonstrated high flow-rate accuracy when tested in vivo and in vitro at normal body temperature and environmental pressure as well as when tested in vivo at variable sheep body temperature. The flow-rate accuracy of the MedStream Programmable Pump across its flow-rate range, compares favorably to the accuracy of current clinically utilized programmable IT infusion pumps reported at specific flow-rate settings and conditions. © 2011 International Neuromodulation Society.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Resolution A.393(X), adopted on 14 November 1977, Recommendation on International Performance and Test...), Guidelines on the Enhanced Programme of Inspections During Surveys of Bulk Carriers and Oil Tankers, Annex B... reference approved for § 157.445. (c) Oil Companies International Marine Forum (OCIMF) 27 Queen Anne's Gate...
Metropolitan Washington Area Water Supply Study. Appendix G. Non-Structural Studies.
1983-09-01
should minimize any impacts to the surrounding areas. The effects of land application systems on the socio -economic aspects of a community include... conflict this outfall might create with respect to the Washington Aqueduct Emergency Estuary Pumping Station. The operation of this intake, designed for...PB 214 970). " Socio -Economic Impact Study of Alternative Water Supply Systems," Annex D, Volume II, Washington Metropolitan Area Water Supply Study
IEA EBC Annex 66: Definition and simulation of occupant behavior in buildings
Yan, Da; Hong, Tianzhen; Dong, Bing; ...
2017-09-28
Here, more than 30% of the total primary energy in the world is consumed in buildings. It is crucial to reduce building energy consumption in order to preserve energy resources and mitigate global climate change. Building performance simulations have been widely used for the estimation and optimization of building performance, providing reference values for the assessment of building energy consumption and the effects of energy-saving technologies. Among the various factors influencing building energy consumption, occupant behavior has drawn increasing attention. Occupant behavior includes occupant presence, movement, and interaction with building energy devices and systems. However, there are gaps in occupantmore » behavior modeling as different energy modelers have employed varied data and tools to simulate occupant behavior, therefore producing different and incomparable results. Aiming to address these gaps, the International Energy Agency (IEA) Energy in Buildings and Community (EBC) Programme Annex 66 has established a scientific methodological framework for occupant behavior research, including data collection, behavior model representation, modeling and evaluation approaches, and the integration of behavior modeling tools with building performance simulation programs. Annex 66 also includes case studies and application guidelines to assist in building design, operation, and policymaking, using interdisciplinary approaches to reduce energy use in buildings and improve occupant comfort and productivity. This paper highlights the key research issues, methods, and outcomes pertaining to Annex 66, and offers perspectives on future research needs to integrate occupant behavior with the building life cycle.« less
IEA EBC Annex 66: Definition and simulation of occupant behavior in buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yan, Da; Hong, Tianzhen; Dong, Bing
Here, more than 30% of the total primary energy in the world is consumed in buildings. It is crucial to reduce building energy consumption in order to preserve energy resources and mitigate global climate change. Building performance simulations have been widely used for the estimation and optimization of building performance, providing reference values for the assessment of building energy consumption and the effects of energy-saving technologies. Among the various factors influencing building energy consumption, occupant behavior has drawn increasing attention. Occupant behavior includes occupant presence, movement, and interaction with building energy devices and systems. However, there are gaps in occupantmore » behavior modeling as different energy modelers have employed varied data and tools to simulate occupant behavior, therefore producing different and incomparable results. Aiming to address these gaps, the International Energy Agency (IEA) Energy in Buildings and Community (EBC) Programme Annex 66 has established a scientific methodological framework for occupant behavior research, including data collection, behavior model representation, modeling and evaluation approaches, and the integration of behavior modeling tools with building performance simulation programs. Annex 66 also includes case studies and application guidelines to assist in building design, operation, and policymaking, using interdisciplinary approaches to reduce energy use in buildings and improve occupant comfort and productivity. This paper highlights the key research issues, methods, and outcomes pertaining to Annex 66, and offers perspectives on future research needs to integrate occupant behavior with the building life cycle.« less
Programmable control means for providing safe and controlled medication infusion
NASA Technical Reports Server (NTRS)
Fischell, Robert E. (Inventor)
1988-01-01
An implantable programmable infusion pump (IPIP) is disclosed and generally includes: a fluid reservoir filled with selected medication; a pump for causing a precise volumetric dosage of medication to be withdrawn from the reservoir and delivered to the appropriate site within the body; and, a control means for actuating the pump in a safe and programmable manner. The control means includes a microprocessor, a permanent memory containing a series of fixed software instructions, and a memory for storing prescription schedules, dosage limits and other data. The microprocessor actuates the pump in accordance with programmable prescription parameters and dosage limits stored in the memory. A communication link allows the control means to be remotely programmed. The control means incorporates a running integral dosage limit and other safety features which prevent an inadvertent or intentional medication overdose. The control means also monitors the pump and fluid handling system and provides an alert if any improper or potentially unsafe operation is detected.
NASA Astrophysics Data System (ADS)
Raatschen, W.; Sjoegren, M.
The subject of indoor and outdoor air quality has generated a great deal of attention in many countries. Areas of concern include outgassing of building materials as well as occupant-generated pollutants such as carbon dioxide, moisture, and odors. Progress has also been made towards addressing issues relating to the air tightness of the building envelope. Indoor air quality studies indicate that better control of supply flow rates as well as the air distribution pattern within buildings are necessary. One method of maintaining good indoor air quality without extensive energy consumption is to control the ventilation rate according to the needs and demands of the occupants, or to preserve the building envelope. This is accomplished through the use of demand controlled ventilating (DCV) systems. The specific objective of Annex 18 is to develop guidelines for demand controlled ventilating systems based on state of the art analyses, case studies on ventilation effectiveness, and proposed ventilation rates for different users in domestic, office, and school buildings.
Software Agents as Facilitators of Coherent Coalition Operations
2001-06-01
In this regard, an important output from DARPA’s CoABS programme is the CoABS Grid - a middleware layer based on Java / Jini technology that provides...2 The C3I Group, Technical Panel 9. 6 developed between two countries who are fighting for control of Binni. To the north is Gao - which has...well developed and fundamentalist country. Gao has managed to annex an area of land, called it Binni and has put in its own puppet government. This
Paper pump for passive and programmable transport
Wang, Xiao; Hagen, Joshua A.; Papautsky, Ian
2013-01-01
In microfluidic systems, a pump for fluid-driving is often necessary. To keep the size of microfluidic systems small, a pump that is small in size, light-weight and needs no external power source is advantageous. In this work, we present a passive, simple, ultra-low-cost, and easily controlled pumping method based on capillary action of paper that pumps fluid through conventional polymer-based microfluidic channels with steady flow rate. By using inexpensive cutting tools, paper can be shaped and placed at the outlet port of a conventional microfluidic channel, providing a wide range of pumping rates. A theoretical model was developed to describe the pumping mechanism and aid in the design of paper pumps. As we show, paper pumps can provide steady flow rates from 0.3 μl/s to 1.7 μl/s and can be cascaded to achieve programmable flow-rate tuning during the pumping process. We also successfully demonstrate transport of the most common biofluids (urine, serum, and blood). With these capabilities, the paper pump has the potential to become a powerful fluid-driving approach that will benefit the fielding of microfluidic systems for point-of-care applications. PMID:24403999
1. Occident Terminal Elevator and annex, (l)1930/workhouse and annex 1925 ...
1. Occident Terminal Elevator and annex, (l)-1930/workhouse and annex 1925 with train shed Peavey Duluth Terminal Annex on left 1930-workhouse 1908 (white silos). - Occident Terminal Elevator & Storage Annex, South side of second slip, north from outer end of Rice's Point, east of Garfield Avenue, Duluth, St. Louis County, MN
NASA Technical Reports Server (NTRS)
1978-01-01
A description is given of the Installation, Operation, and Maintenance Manual and information on the power panel and programmable microprocessor, a hydronic solar pump system and a hydronic heating hot water pumping system. These systems are integrated into various configurations for usages in solar energy management, control and monitoring, lighting control, data logging and other solar related applications.
2015-05-01
objectives, and four annexes: the Human Capital Annex ( HCA ), Strategic Posture Annex (SPA), Capabilities Annex (CA), and the Science and Technology...translate the SMP’s comprehensive goals and objectives into tangible actions and priorities. The four annexes are as follows: Human Capital Annex ( HCA ...Figure 1: Internal Structure of the SMP Through the HCA , SPA, CA, and STA, the SMP consolidates and transmits strategic direction to staffs
Ordia, Joe I; Fischer, Edward; Adamski, Ellen; Chagnon, Kimberly G; Spatz, Edward L
2002-01-01
We began this study to determine the efficacy and safety of intrathecal baclofen (ITB) delivered by a programmable pump for the treatment of severe spasticity of spinal cord origin. One hundred fifty two patients with severe spasticity of spinal origin, refractory to oral baclofen, or who experienced intolerable side-effects were given a test dose of ITB. Only those who had a satisfactory response were considered to be appropriate for pump implantation. All but one of the 152 patients had a satisfactory response, and the pump was implanted in 131 patients. Pre- and postoperative spasticity scores were compared and analyzed. The mean Ashworth score for rigidity decreased from 4.2 preoperatively to 1.3 (p < 0.0005) on ITB. The spasm score decreased from a mean of 3.4 to 0.6 (p < 0.0005). Reduction of spasticity resulted in improved levels of physical activity, decreased pain, and augmentation of sleep. Drug-related complications included constipation, muscular hypotonia, urinary retention, erectile dysfunction, nausea, dizziness, drowsiness, hypotension and bradycardia as well as tolerance to baclofen. Some patients experienced post-spinal puncture headaches. Catheter-related problems included occlusions, breaks, punctures, and dislodgments. Superficial pump pocket infection, pocket erosion, cerebrospinal fluid (CSF) leak, post-spinal puncture headache, and meningitis were some of the procedure-related complications. Two pumps flipped and another pump valve was stuck. We conclude that long-term intrathecal baclofen by an implanted programmable pump is a safe and effective method of treating severe intractable spinal spasticity.
2017-07-31
Telemetry Standards, IRIG Standard 106-17 Annex A.2, May 2017 ANNEX A.2 Magnetic Tape Recorder and Reproducer Information and Use Criteria...Annex A.2, May 2017 A.2-1 ANNEX A.2 Magnetic Tape Recorder and Reproducer Information and Use Criteria 1. Other Instrumentation Magnetic Tape...http://webstore.ansi.org). Documentation applicable to this annex is identified in the following bullets. • ISO 1860 (1986), Information Processing
Programmable Infusion Pumps in ICUs: An Analysis of Corresponding Adverse Drug Events
Bower, Anthony G.; Paddock, Susan M.; Hilborne, Lee H.; Wallace, Peggy; Rothschild, Jeffrey M.; Griffin, Anne; Fairbanks, Rollin J.; Carlson, Beverly; Panzer, Robert J.; Brook, Robert H.
2007-01-01
Background Patients in intensive care units (ICUs) frequently experience adverse drug events involving intravenous medications (IV-ADEs), which are often preventable. Objectives To determine how frequently preventable IV-ADEs in ICUs match the safety features of a programmable infusion pump with safety software (“smart pump”) and to suggest potential improvements in smart-pump design. Design Using retrospective medical-record review, we examined preventable IV-ADEs in ICUs before and after 2 hospitals replaced conventional pumps with smart pumps. The smart pumps alerted users when programmed to deliver duplicate infusions or continuous-infusion doses outside hospital-defined ranges. Participants 4,604 critically ill adults at 1 academic and 1 nonacademic hospital. Measurements Preventable IV-ADEs matching smart-pump features and errors involved in preventable IV-ADEs. Results Of 100 preventable IV-ADEs identified, 4 involved errors matching smart-pump features. Two occurred before and 2 after smart-pump implementation. Overall, 29% of preventable IV-ADEs involved overdoses; 37%, failures to monitor for potential problems; and 45%, failures to intervene when problems appeared. Error descriptions suggested that expanding smart pumps’ capabilities might enable them to prevent more IV-ADEs. Conclusion The smart pumps we evaluated are unlikely to reduce preventable IV-ADEs in ICUs because they address only 4% of them. Expanding smart-pump capabilities might prevent more IV-ADEs. PMID:18095043
IRSHAD, Abdul Razaq; SASAKI, Taihei; KUBO, Tomoaki; ODASHIMA, Naoyuki; KATANO, Keiji; OSAWA, Takeshi; TAKAHASHI, Toru; IZAIKE, Yoshiaki
2015-01-01
The objectives of the present study were to develop a programmable piggyback syringe pump for bovine superovulation and to evaluate the effects of a four-times-a-day injection regimen using the pump. Non-lactating Holstein cows were treated with a total of 30 armour units of porcine FSH by injection four times a day with the pump (study, n = 9) or injection twice a day manually (control, n = 9) for four consecutive days from D10 of the estrous cycle. The pump-driven program successfully induced superovulation in all cows tested. The numbers of small (3– < 5 mm in diameter) and large (≥ 10 mm in diameter) follicles were greater in the study group on D11-13 and D14, respectively. There were fewer unovulated follicles detected on D21 (7 days after estrus) in the study group than in the control group (1.2 ± 0.4 and 3.2 ± 0.6, respectively). PMID:26052155
Irshad, Abdul Razaq; Sasaki, Taihei; Kubo, Tomoaki; Odashima, Naoyuki; Katano, Keiji; Osawa, Takeshi; Takahashi, Toru; Izaike, Yoshiaki
2015-01-01
The objectives of the present study were to develop a programmable piggyback syringe pump for bovine superovulation and to evaluate the effects of a four-times-a-day injection regimen using the pump. Non-lactating Holstein cows were treated with a total of 30 armour units of porcine FSH by injection four times a day with the pump (study, n = 9) or injection twice a day manually (control, n = 9) for four consecutive days from D10 of the estrous cycle. The pump-driven program successfully induced superovulation in all cows tested. The numbers of small (3- < 5 mm in diameter) and large (≥ 10 mm in diameter) follicles were greater in the study group on D11-13 and D14, respectively. There were fewer unovulated follicles detected on D21 (7 days after estrus) in the study group than in the control group (1.2 ± 0.4 and 3.2 ± 0.6, respectively).
De Andres, Jose; Villanueva, Vicente; Palmisani, Stefano; Cerda-Olmedo, German; Lopez-Alarcon, Maria Dolores; Monsalve, Vicente; Minguez, Ana; Martinez-Sanjuan, Vicente
2011-05-01
It is common clinical practice to perform magnetic resonance imaging (MRI) in patients with indwelling programmable intrathecal drug delivery (IDD) systems, although the safety of the procedure has never been documented. We performed a single-center, 3-year, prospective evaluation in patients with a programmable implanted IDD to assess patient discomfort, IDD technical failures, and adverse effects during and after exposure to MRI. Forty-three consecutive patients with an implanted programmable IDD system (SynchroMed® EL Implantable Infusion Pump, Model 8626L-18, and SynchroMed® II Model 8637-20, 8637-40; Medtronic, Inc., Minneapolis, MN) requiring a scheduled MRI evaluation were studied during a 3-year period. All MRI scans were performed with a 1.5-tesla clinical use magnet and a specific absorption rate of no more than 0.9 W/kg. Radiograph control was used to confirm postexposure pump rotor movement and detect system dislocations. IDD system failures, patient satisfaction, and discomfort were recorded. None of the patients experienced signs of drug overinfusion that could lead to hemodynamic, respiratory, or neurologic alterations. Radiologic evaluation after MRI revealed no spatial displacements of the intrathecal catheter tip or body pump, and programmer telemetry confirmed the infusion recovery. Patients' satisfaction after the procedure was high. Performing an MRI scan with the proposed protocol in patients with an implanted Medtronic programmable IDD system resulted in virtually no technical or medical complications. © 2011 International Anesthesia Research Society
Tan, Tsung; Watts, Stephanie W.; Davis, Robert Patrick
2011-01-01
Successful drug delivery using implantable pumps may be found in over 12,500 published articles. Their versatility in delivering continuous infusion, intermittent or complex infusion protocols acutely or chronically has made them ubiquitous in drug discovery and basic research. The recent availability of iPRECIO®, a programmable, refillable, and implantable infusion pump has made it possible to carry out quantitative pharmacology (PKPD) in single animals. When combined with specialized catheters, specific administration sites have been selected. When combined with radiotelemetry, the physiologic gold standard, more sensitive and powerful means of detecting drug induced therapeutic, and/or adverse effects has been possible. Numerous application examples are cited from iPRECIO® use in Japan, United States, and Europe with iPRECIO® as an enabling drug delivery device where the refillable and programmability functionality were key benefits. The ability to start/stop drug delivery and to have control periods prior dosing made it possible to have equivalent effects at a much lower dose than previously studied. Five different iPRECIO® applications are described in detail with references to the original work where the implantable, refillable, and programmable benefits are demonstrated with their different end-points. PMID:21863140
Computer controlled fluorometer device and method of operating same
Kolber, Z.; Falkowski, P.
1990-07-17
A computer controlled fluorometer device and method of operating same, said device being made to include a pump flash source and a probe flash source and one or more sample chambers in combination with a light condenser lens system and associated filters and reflectors and collimators, as well as signal conditioning and monitoring means and a programmable computer means and a software programmable source of background irradiance that is operable according to the method of the invention to rapidly, efficiently and accurately measure photosynthetic activity by precisely monitoring and recording changes in fluorescence yield produced by a controlled series of predetermined cycles of probe and pump flashes from the respective probe and pump sources that are controlled by the computer means. 13 figs.
Computer controlled fluorometer device and method of operating same
Kolber, Zbigniew; Falkowski, Paul
1990-01-01
A computer controlled fluorometer device and method of operating same, said device being made to include a pump flash source and a probe flash source and one or more sample chambers in combination with a light condenser lens system and associated filters and reflectors and collimators, as well as signal conditioning and monitoring means and a programmable computer means and a software programmable source of background irradiance that is operable according to the method of the invention to rapidly, efficiently and accurately measure photosynthetic activity by precisely monitoring and recording changes in fluorescence yield produced by a controlled series of predetermined cycles of probe and pump flashes from the respective probe and pump sources that are controlled by the computer means.
19 CFR Annex Viii-B to Part 351 - Schedule for Expedited Sunset Reviews
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 3 2010-04-01 2010-04-01 false Schedule for Expedited Sunset Reviews VIII Annex VIII-B to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VIII-B Annex VIII-B to Part 351—Schedule for Expedited...
19 CFR Annex Vii to Part 351 - Antidumping Investigations Timeline
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 3 2010-04-01 2010-04-01 false Antidumping Investigations Timeline VII Annex VII to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VII Annex VII to Part 351—Antidumping Investigations Timeline ER19MY97.001 ...
19 CFR Annex IV to Part 351 - Deadlines for Parties in Antidumping Administrative Reviews
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 3 2010-04-01 2010-04-01 false Deadlines for Parties in Antidumping Administrative Reviews IV Annex IV to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex IV Annex IV to Part 351—Deadlines for Parties...
19 CFR Annex III to Part 351 - Deadlines for Parties in Antidumping Investigations
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 3 2010-04-01 2010-04-01 false Deadlines for Parties in Antidumping Investigations III Annex III to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex III Annex III to Part 351—Deadlines for...
19 CFR Annex I to Part 351 - Deadlines for Parties in Countervailing Investigations
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 3 2010-04-01 2010-04-01 false Deadlines for Parties in Countervailing Investigations I Annex I to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex I Annex I to Part 351—Deadlines for Parties in...
19 CFR Annex Vi to Part 351 - Countervailing Investigations Timeline
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 3 2010-04-01 2010-04-01 false Countervailing Investigations Timeline VI Annex VI to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VI Annex VI to Part 351—Countervailing Investigations Timeline ER19MY97.000 ...
19 CFR Annex II to Part 351 - Deadlines for Parties in Countervailing Administrative Reviews
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 3 2010-04-01 2010-04-01 false Deadlines for Parties in Countervailing Administrative Reviews II Annex II to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex II Annex II to Part 351—Deadlines for Parties...
19 CFR Annex II to Part 351 - Deadlines for Parties in Countervailing Administrative Reviews
Code of Federal Regulations, 2011 CFR
2011-04-01
... 19 Customs Duties 3 2011-04-01 2011-04-01 false Deadlines for Parties in Countervailing Administrative Reviews II Annex II to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex II Annex II to Part 351—Deadlines for Parties...
19 CFR Annex Viii-B to Part 351 - Schedule for Expedited Sunset Reviews
Code of Federal Regulations, 2011 CFR
2011-04-01
... 19 Customs Duties 3 2011-04-01 2011-04-01 false Schedule for Expedited Sunset Reviews VIII Annex VIII-B to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VIII-B Annex VIII-B to Part 351—Schedule for Expedited...
19 CFR Annex Vii to Part 351 - Antidumping Investigations Timeline
Code of Federal Regulations, 2014 CFR
2014-04-01
... 19 Customs Duties 3 2014-04-01 2014-04-01 false Antidumping Investigations Timeline VII Annex VII to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VII Annex VII to Part 351—Antidumping Investigations Timeline ER19MY97.001 ...
19 CFR Annex IV to Part 351 - Deadlines for Parties in Antidumping Administrative Reviews
Code of Federal Regulations, 2013 CFR
2013-04-01
... 19 Customs Duties 3 2013-04-01 2013-04-01 false Deadlines for Parties in Antidumping Administrative Reviews IV Annex IV to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex IV Annex IV to Part 351—Deadlines for Parties...
19 CFR Annex III to Part 351 - Deadlines for Parties in Antidumping Investigations
Code of Federal Regulations, 2012 CFR
2012-04-01
... 19 Customs Duties 3 2012-04-01 2012-04-01 false Deadlines for Parties in Antidumping Investigations III Annex III to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex III Annex III to Part 351—Deadlines for...
19 CFR Annex I to Part 351 - Deadlines for Parties in Countervailing Investigations
Code of Federal Regulations, 2012 CFR
2012-04-01
... 19 Customs Duties 3 2012-04-01 2012-04-01 false Deadlines for Parties in Countervailing Investigations I Annex I to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex I Annex I to Part 351—Deadlines for Parties in...
19 CFR Annex Vi to Part 351 - Countervailing Investigations Timeline
Code of Federal Regulations, 2013 CFR
2013-04-01
... 19 Customs Duties 3 2013-04-01 2013-04-01 false Countervailing Investigations Timeline VI Annex VI to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VI Annex VI to Part 351—Countervailing Investigations Timeline ER19MY97.000 ...
19 CFR Annex Vii to Part 351 - Antidumping Investigations Timeline
Code of Federal Regulations, 2011 CFR
2011-04-01
... 19 Customs Duties 3 2011-04-01 2011-04-01 false Antidumping Investigations Timeline VII Annex VII to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VII Annex VII to Part 351—Antidumping Investigations Timeline ER19MY97.001 ...
19 CFR Annex Vi to Part 351 - Countervailing Investigations Timeline
Code of Federal Regulations, 2014 CFR
2014-04-01
... 19 Customs Duties 3 2014-04-01 2014-04-01 false Countervailing Investigations Timeline VI Annex VI to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VI Annex VI to Part 351—Countervailing Investigations Timeline ER19MY97.000 ...
19 CFR Annex II to Part 351 - Deadlines for Parties in Countervailing Administrative Reviews
Code of Federal Regulations, 2014 CFR
2014-04-01
... 19 Customs Duties 3 2014-04-01 2014-04-01 false Deadlines for Parties in Countervailing Administrative Reviews II Annex II to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex II Annex II to Part 351—Deadlines for Parties...
19 CFR Annex III to Part 351 - Deadlines for Parties in Antidumping Investigations
Code of Federal Regulations, 2013 CFR
2013-04-01
... 19 Customs Duties 3 2013-04-01 2013-04-01 false Deadlines for Parties in Antidumping Investigations III Annex III to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex III Annex III to Part 351—Deadlines for...
19 CFR Annex IV to Part 351 - Deadlines for Parties in Antidumping Administrative Reviews
Code of Federal Regulations, 2014 CFR
2014-04-01
... 19 Customs Duties 3 2014-04-01 2014-04-01 false Deadlines for Parties in Antidumping Administrative Reviews IV Annex IV to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex IV Annex IV to Part 351—Deadlines for Parties...
19 CFR Annex Vii to Part 351 - Antidumping Investigations Timeline
Code of Federal Regulations, 2013 CFR
2013-04-01
... 19 Customs Duties 3 2013-04-01 2013-04-01 false Antidumping Investigations Timeline VII Annex VII to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VII Annex VII to Part 351—Antidumping Investigations Timeline ER19MY97.001 ...
19 CFR Annex I to Part 351 - Deadlines for Parties in Countervailing Investigations
Code of Federal Regulations, 2014 CFR
2014-04-01
... 19 Customs Duties 3 2014-04-01 2014-04-01 false Deadlines for Parties in Countervailing Investigations I Annex I to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex I Annex I to Part 351—Deadlines for Parties in...
19 CFR Annex Vii to Part 351 - Antidumping Investigations Timeline
Code of Federal Regulations, 2012 CFR
2012-04-01
... 19 Customs Duties 3 2012-04-01 2012-04-01 false Antidumping Investigations Timeline VII Annex VII to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VII Annex VII to Part 351—Antidumping Investigations Timeline ER19MY97.001 ...
19 CFR Annex Viii-B to Part 351 - Schedule for Expedited Sunset Reviews
Code of Federal Regulations, 2013 CFR
2013-04-01
... 19 Customs Duties 3 2013-04-01 2013-04-01 false Schedule for Expedited Sunset Reviews VIII Annex VIII-B to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VIII-B Annex VIII-B to Part 351—Schedule for Expedited...
19 CFR Annex Vi to Part 351 - Countervailing Investigations Timeline
Code of Federal Regulations, 2012 CFR
2012-04-01
... 19 Customs Duties 3 2012-04-01 2012-04-01 false Countervailing Investigations Timeline VI Annex VI to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VI Annex VI to Part 351—Countervailing Investigations Timeline ER19MY97.000 ...
19 CFR Annex Vi to Part 351 - Countervailing Investigations Timeline
Code of Federal Regulations, 2011 CFR
2011-04-01
... 19 Customs Duties 3 2011-04-01 2011-04-01 false Countervailing Investigations Timeline VI Annex VI to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VI Annex VI to Part 351—Countervailing Investigations Timeline ER19MY97.000 ...
19 CFR Annex IV to Part 351 - Deadlines for Parties in Antidumping Administrative Reviews
Code of Federal Regulations, 2012 CFR
2012-04-01
... 19 Customs Duties 3 2012-04-01 2012-04-01 false Deadlines for Parties in Antidumping Administrative Reviews IV Annex IV to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex IV Annex IV to Part 351—Deadlines for Parties...
19 CFR Annex III to Part 351 - Deadlines for Parties in Antidumping Investigations
Code of Federal Regulations, 2014 CFR
2014-04-01
... 19 Customs Duties 3 2014-04-01 2014-04-01 false Deadlines for Parties in Antidumping Investigations III Annex III to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex III Annex III to Part 351—Deadlines for...
19 CFR Annex II to Part 351 - Deadlines for Parties in Countervailing Administrative Reviews
Code of Federal Regulations, 2013 CFR
2013-04-01
... 19 Customs Duties 3 2013-04-01 2013-04-01 false Deadlines for Parties in Countervailing Administrative Reviews II Annex II to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex II Annex II to Part 351—Deadlines for Parties...
19 CFR Annex Viii-B to Part 351 - Schedule for Expedited Sunset Reviews
Code of Federal Regulations, 2014 CFR
2014-04-01
... 19 Customs Duties 3 2014-04-01 2014-04-01 false Schedule for Expedited Sunset Reviews VIII Annex VIII-B to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VIII-B Annex VIII-B to Part 351—Schedule for Expedited...
19 CFR Annex Viii-B to Part 351 - Schedule for Expedited Sunset Reviews
Code of Federal Regulations, 2012 CFR
2012-04-01
... 19 Customs Duties 3 2012-04-01 2012-04-01 false Schedule for Expedited Sunset Reviews VIII Annex VIII-B to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VIII-B Annex VIII-B to Part 351—Schedule for Expedited...
19 CFR Annex I to Part 351 - Deadlines for Parties in Countervailing Investigations
Code of Federal Regulations, 2011 CFR
2011-04-01
... 19 Customs Duties 3 2011-04-01 2011-04-01 false Deadlines for Parties in Countervailing Investigations I Annex I to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex I Annex I to Part 351—Deadlines for Parties in...
19 CFR Annex I to Part 351 - Deadlines for Parties in Countervailing Investigations
Code of Federal Regulations, 2013 CFR
2013-04-01
... 19 Customs Duties 3 2013-04-01 2013-04-01 false Deadlines for Parties in Countervailing Investigations I Annex I to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex I Annex I to Part 351—Deadlines for Parties in...
19 CFR Annex III to Part 351 - Deadlines for Parties in Antidumping Investigations
Code of Federal Regulations, 2011 CFR
2011-04-01
... 19 Customs Duties 3 2011-04-01 2011-04-01 false Deadlines for Parties in Antidumping Investigations III Annex III to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex III Annex III to Part 351—Deadlines for...
19 CFR Annex IV to Part 351 - Deadlines for Parties in Antidumping Administrative Reviews
Code of Federal Regulations, 2011 CFR
2011-04-01
... 19 Customs Duties 3 2011-04-01 2011-04-01 false Deadlines for Parties in Antidumping Administrative Reviews IV Annex IV to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex IV Annex IV to Part 351—Deadlines for Parties...
19 CFR Annex II to Part 351 - Deadlines for Parties in Countervailing Administrative Reviews
Code of Federal Regulations, 2012 CFR
2012-04-01
... 19 Customs Duties 3 2012-04-01 2012-04-01 false Deadlines for Parties in Countervailing Administrative Reviews II Annex II to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex II Annex II to Part 351—Deadlines for Parties...
Experimental investigations into cryosorption pumping of plasma exhaust
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perinic, D.; Mack, A.
1988-09-01
Within the framework of the European Fusion Technology Programme the Karlsruhe Nuclear Research Centre has been awarded a contract for the development of cryosorption panels for compound cryopumps of the NEt plasma exhaust pumping system. This task includes the development of a bonding technique for porous sorbent materials with metal substrates and a test programme for development and optimization of cryopanels. A variety of material combinations for sorbent, bonding and substrate were evaluated and listed in a test matrix. Bonding tests involving soldering, cementing and plasma spraying techniques have been carried out.
Flow pumping system for physiological waveforms.
Tsai, William; Savaş, Omer
2010-02-01
A pulsatile flow pumping system is developed to replicate flow waveforms with reasonable accuracy for experiments simulating physiological blood flows at numerous points in the body. The system divides the task of flow waveform generation between two pumps: a gear pump generates the mean component and a piston pump generates the oscillatory component. The system is driven by two programmable servo controllers. The frequency response of the system is used to characterize its operation. The system has been successfully tested in vascular flow experiments where sinusoidal, carotid, and coronary flow waveforms are replicated.
19 CFR Annex Viii-A to Part 351 - Schedule for 90-Day Sunset Reviews
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 3 2010-04-01 2010-04-01 false Schedule for 90-Day Sunset Reviews VIII Annex VIII-A to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VIII-A Annex VIII-A to Part 351—Schedule for 90-Day Sunset...
19 CFR Annex Viii-A to Part 351 - Schedule for 90-Day Sunset Reviews
Code of Federal Regulations, 2014 CFR
2014-04-01
... 19 Customs Duties 3 2014-04-01 2014-04-01 false Schedule for 90-Day Sunset Reviews VIII Annex VIII-A to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VIII-A Annex VIII-A to Part 351—Schedule for 90-Day Sunset...
19 CFR Annex Viii-A to Part 351 - Schedule for 90-Day Sunset Reviews
Code of Federal Regulations, 2012 CFR
2012-04-01
... 19 Customs Duties 3 2012-04-01 2012-04-01 false Schedule for 90-Day Sunset Reviews VIII Annex VIII-A to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VIII-A Annex VIII-A to Part 351—Schedule for 90-Day Sunset...
19 CFR Annex Viii-A to Part 351 - Schedule for 90-Day Sunset Reviews
Code of Federal Regulations, 2013 CFR
2013-04-01
... 19 Customs Duties 3 2013-04-01 2013-04-01 false Schedule for 90-Day Sunset Reviews VIII Annex VIII-A to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VIII-A Annex VIII-A to Part 351—Schedule for 90-Day Sunset...
19 CFR Annex Viii-A to Part 351 - Schedule for 90-Day Sunset Reviews
Code of Federal Regulations, 2011 CFR
2011-04-01
... 19 Customs Duties 3 2011-04-01 2011-04-01 false Schedule for 90-Day Sunset Reviews VIII Annex VIII-A to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VIII-A Annex VIII-A to Part 351—Schedule for 90-Day Sunset...
76 FR 19380 - Notice of Entry Into Effect of MARPOL Annex V Wider Caribbean Region Special Area
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-07
... Effect of MARPOL Annex V Wider Caribbean Region Special Area AGENCY: Coast Guard, DHS. ACTION: Notice... for the Prevention of Pollution from Ships (MARPOL) Annex V, Regulation 5 and Coast Guard regulations. MARPOL Annex V and the U.S. regulations apply to vessel and reception facility activities in the WCR...
Code of Federal Regulations, 2010 CFR
2010-04-01
... the Missile Technology Control Regime Annex. 121.2 Section 121.2 Foreign Relations DEPARTMENT OF STATE... Interpretations of the U.S. Munitions List and the Missile Technology Control Regime Annex. The following... Munitions List which are Missile Technology Control Regime Annex items in accordance with section 71(a) of...
Code of Federal Regulations, 2011 CFR
2011-04-01
... the Missile Technology Control Regime Annex. 121.2 Section 121.2 Foreign Relations DEPARTMENT OF STATE... Interpretations of the U.S. Munitions List and the Missile Technology Control Regime Annex. The following... Munitions List which are Missile Technology Control Regime Annex items in accordance with section 71(a) of...
Code of Federal Regulations, 2013 CFR
2013-04-01
... the Missile Technology Control Regime Annex. 121.2 Section 121.2 Foreign Relations DEPARTMENT OF STATE... Interpretations of the U.S. Munitions List and the Missile Technology Control Regime Annex. The following... Munitions List which are Missile Technology Control Regime Annex items in accordance with section 71(a) of...
Code of Federal Regulations, 2012 CFR
2012-04-01
... the Missile Technology Control Regime Annex. 121.2 Section 121.2 Foreign Relations DEPARTMENT OF STATE... Interpretations of the U.S. Munitions List and the Missile Technology Control Regime Annex. The following... Munitions List which are Missile Technology Control Regime Annex items in accordance with section 71(a) of...
Primary Education in Pakistan. Part IV. Annexes to the Analysis.
ERIC Educational Resources Information Center
Development Associates, Inc., Arlington, VA.
The fourth part of a four-part analysis and assessment of Pakistan's system of primary education presents annexes to the analysis that was reported in the second part of the overall report. Five annexes are included: (A) Acronyms; (B) Scope of Work; (C) Persons Interviewed; (D) Chapter Annexes; and (E) Bibliography. A number of charts and diagrams…
19 CFR Annex Viii-C to Part 351 - Schedule for Full Sunset Reviews
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 3 2010-04-01 2010-04-01 false Schedule for Full Sunset Reviews VIII Annex VIII-C to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VIII-C Annex VIII-C to Part 351—Schedule for Full Sunset Reviews Day 1 Event...
19 CFR Annex Viii-C to Part 351 - Schedule for Full Sunset Reviews
Code of Federal Regulations, 2014 CFR
2014-04-01
... 19 Customs Duties 3 2014-04-01 2014-04-01 false Schedule for Full Sunset Reviews VIII Annex VIII-C to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VIII-C Annex VIII-C to Part 351—Schedule for Full Sunset Reviews Day 1 Event...
19 CFR Annex Viii-C to Part 351 - Schedule for Full Sunset Reviews
Code of Federal Regulations, 2011 CFR
2011-04-01
... 19 Customs Duties 3 2011-04-01 2011-04-01 false Schedule for Full Sunset Reviews VIII Annex VIII-C to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VIII-C Annex VIII-C to Part 351—Schedule for Full Sunset Reviews Day 1 Event...
19 CFR Annex Viii-C to Part 351 - Schedule for Full Sunset Reviews
Code of Federal Regulations, 2013 CFR
2013-04-01
... 19 Customs Duties 3 2013-04-01 2013-04-01 false Schedule for Full Sunset Reviews VIII Annex VIII-C to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VIII-C Annex VIII-C to Part 351—Schedule for Full Sunset Reviews Day 1 Event...
19 CFR Annex Viii-C to Part 351 - Schedule for Full Sunset Reviews
Code of Federal Regulations, 2012 CFR
2012-04-01
... 19 Customs Duties 3 2012-04-01 2012-04-01 false Schedule for Full Sunset Reviews VIII Annex VIII-C to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VIII-C Annex VIII-C to Part 351—Schedule for Full Sunset Reviews Day 1 Event...
2011-11-01
International Convention for the Prevention of Pollution From Ships, 1973 as modified by the Protocol of 1978 (MARPOL 73/78). Under MARPOL, all ships...of oily bilgewater discharge from vessels are based on Annex I of the International Convention for the Prevention of Pollution from Ships, 1973 as...to the Convention . MARPOL includes six annexes, covering six categories of vessel discharges: oil (Annex I), noxious liquid substances (Annex II
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-08
... safety, Navigation (water), and Vessels. For the reasons set forth in the preamble, the Navy amends part... meters; Rule in meters; light in sides in meters; in meters; (i) Rule 21(e), 30(a)(ii) Sec. meters; meters; Rule 21(a) Sec. Rule 2(g), Annex Sec. Sec. 2(K), 30(a)(ii) I 3(b), Annex 3(b), Annex Annex I I I...
IEA agreement on the production and utilization of hydrogen: 2000 annual report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elam, Carolyn C.
2001-12-01
The 2000 annual report of the IEA Hydrogen Agreement contains an overview of the agreement, including its guiding principles, latest strategic plan, and a report from the Chairman, Mr. Neil P. Rossmeissl, U.S. Department of Energy. Overviews of the National Hydrogen Programs of nine member countries are given: Canada, Japan, Lithuania, the Netherlands, Norway, Spain, Sweden, Switzerland, and the United States. Task updates are provided on the following annexes: Annex 12 - Metal Hydrides and Carbon for Hydrogen Storage, Annex 13 - Design and Optimization of Integrated Systems, Annex 14 - Photoelectrolytic Production of Hydrogen, and, Annex 15 - Photobiologicalmore » Production of Hydrogen.« less
1975-03-14
Mar 14, 75 GENERAL INSTRUCTIONS FOR USE AND PREPARATION OF ENLISTMENT OR REENLISTMENT AGREEMENT - ARMED FORCES OF THE UNITED STATES DD FORM 4 1. Use. a...Forces. Any individual dis- charged from DEP and not immediately enlisted in a regular component will, upon enlistment in an armed service, require a new ...Annex If enlistment options or programs have changed since original enlistment in the DEP, enter in the first space for Annex - the new annex(es). In the
Cognitive Task Analysis of the HALIFAX-Class Operations Room Officer: Data Sheets. Annexes
1999-03-10
Image Cover Sheet CLASSIFICATION SYSTEM NUMBER 510920 UNCLASSIFIED 1111111111111111111111111111111111111111 TITLE ANNEXES TO: COGNITIVE TASK ANALYSIS OF...1999 2. REPORT TYPE 3. DATES COVERED 00-00-1999 to 00-00-1999 4. TITLE AND SUBTITLE Annexes to: Cognitive Task Analysis of the HALIFAX-Class...by ANSI Std Z39-18 Guelph, Ontario .H U. M A N S X S T E M S Incorporated Annexes to: Cognitive Task Analysis of the HALIFAX-Class Operations
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-13
... fuels, for purposes of propulsion or operation on board a ship. Also, new Annex VI Regulations 20 and 21.... 10, 2012). Annex VI exempts ships using diesel-electric, turbine or hybrid propulsion systems from...
Pump-probe micro-spectroscopy by means of an ultra-fast acousto-optics delay line.
Audier, Xavier; Balla, Naveen; Rigneault, Hervé
2017-01-15
We demonstrate femtosecond pump-probe transient absorption spectroscopy using a programmable dispersive filter as an ultra-fast delay line. Combined with fast synchronous detection, this delay line allows for recording of 6 ps decay traces at 34 kHz. With such acquisition speed, we perform single point pump-probe spectroscopy on bulk samples in 80 μs and hyperspectral pump-probe imaging over a field of view of 100 μm in less than a second. The usability of the method is illustrated in a showcase experiment to image and discriminate between two pigments in a mixture.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-07
... military functions. List of Subjects in 32 CFR Part 706 Marine safety, Navigation (water), and Vessels. For... 21(b) rule 21(c) in meters meters; rule meters; 2(k) meters 2(k) 3(b) Annex 1 21(c) Annex 1 Annex 1...
76 FR 45592 - Federal Property Suitable as Facilities To Assist the Homeless
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-29
... Neck Annex Indian Head MD 20640 Landholding Agency: Navy Property Number: 77201130003 Status: Excess..., Extensive deterioration, Secured Area Bldg. 4SN Stump Neck Annex Indian Head MD 20640 Landholding Agency.... Stump Neck Annex Indian Head MD Landholding Agency: Navy Property Number: 77201130008 Status: Excess...
Unusual placement of intrathecal baclofen pumps: report of two cases.
Devine, Oliver; Harborne, Andrew; Lo, William B; Weinberg, Daniel; Ciras, Mahesh; Price, Rupert
2016-01-01
Intrathecal baclofen delivery via implantable pump represents an important modality for symptomatic relief in patients with chronic spasticity. Pumps are routinely implanted subcutaneously in the anterior abdominal wall. We describe two unusual cases where skin-related complications necessitated revision surgery in order to relocate the pump to alternative sites. The first patient was an international power canoeist, whose strenuous exercise programme interfered with his pump's original siting. The second patient was a cachectic university student with a history of cerebral palsy, who maintained low body mass despite attempted weight gain. The relocation of these two intrathecal devices to the medial compartment of the right thigh and right iliac fossa, respectively, is described.
Spectral linewidth preservation in parametric frequency combs seeded by dual pumps.
Tong, Zhi; Wiberg, Andreas O J; Myslivets, Evgeny; Kuo, Bill P P; Alic, Nikola; Radic, Stojan
2012-07-30
We demonstrate new technique for generation of programmable-pitch, wideband frequency combs with low phase noise. The comb generation was achieved using cavity-less, multistage mixer driven by two tunable continuous-wave pump seeds. The approach relies on phase-correlated continuous-wave pumps in order to cancel spectral linewidth broadening inherent to parametric comb generation. Parametric combs with over 200-nm bandwidth were obtained and characterized with respect to phase noise scaling to demonstrate linewidth preservation over 100 generated tones.
The 1897 Petition against the Annexation of Hawaii. Teaching with Documents.
ERIC Educational Resources Information Center
Schamel, Wynell; Schamel, Charles E.
1999-01-01
Describes the history surrounding the 1897 Hawaiian Petition Against Annexation that is stored in the National Archives and Records Administration. Explains that the petition is revered by native Hawaiians because it demonstrates that the Hawaiians opposed annexation by the United States. Provides teaching activities in relation to the petition.…
44. SECOND FLOOR 'ANNEX' INTERIOR VIEW TO SOUTHWEST: Interior ...
44. SECOND FLOOR 'ANNEX' - INTERIOR VIEW TO SOUTHWEST: Interior view towards southwest on second floor of the powerhouse 'annex.' Note the steel column and beam construction and the old shunt car formerly used to move cable cars around the yard. - San Francisco Cable Railway, Washington & Mason Streets, San Francisco, San Francisco County, CA
The Great Lakes Water Quality Agreement with an emphasis on annex 4 nutrients -and Lake Erie
Presented will be an overview of the Great Lakes Water Quality Act of 2012 including a general description of the Annexes and the new Binational Governance. The talk will focus on the Annex 4 Nutrients Subcommittee and the Objectives and Targets Task Team efforts that have been ...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-18
... the Naval Weapons Station Yorktown-Cheatham Annex, Yorktown, Virginia; Danger Zone AGENCY: U.S. Army... follows: Sec. 334.285 York River and the Naval Weapons Station Yorktown- Cheatham Annex, Yorktown...) Enforcement. The regulations in this section shall be enforced by the Commander, Naval Weapons Station...
28 CFR 50.20 - Participation by the United States in court-annexed arbitration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Participation by the United States in court-annexed arbitration. 50.20 Section 50.20 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) STATEMENTS OF POLICY § 50.20 Participation by the United States in court-annexed arbitration. (a) Considerations affecting participation in...
Liu, Xiang; Liu, Jia
2016-01-01
This paper employs a three-stage approach to estimate low carbon economy efficiency in the largest twenty CO2 emitting countries from 2000 to 2012. The approach includes the following three stages: (1) use of a data envelopment analysis (DEA) model with undesirable output to estimate the low carbon economy efficiency and calculate the input and output slacks; (2) use of a stochastic frontier approach to eliminate the impacts of external environment variables on these slacks; (3) re-estimation of the efficiency with adjusted inputs and outputs to reflect the capacity of the government to develop a low carbon economy. The results indicate that the low carbon economy efficiency performances in these countries had worsened during the studied period. The performances in the third stage are larger than that in the first stage. Moreover, in general, low carbon economy efficiency in Annex I countries of the United Nations Framework Convention on Climate Change (UNFCCC) is better than that in Non-Annex I countries. However, the gap of the average efficiency score between Annex I and Non-Annex I countries in the first stage is smaller than that in the third stage. It implies that the external environment variables show greater influence on Non-Annex I countries than that on Annex I countries. These external environment variables should be taken into account in the transnational negotiation of the responsibility of promoting CO2 reductions. Most importantly, the developed countries (mostly in Annex I) should help the developing countries (mostly in Non-Annex I) to reduce carbon emission by opening or expanding the trade, such as encouraging the import and export of the energy-saving and sharing emission reduction technology. PMID:27834890
Liu, Xiang; Liu, Jia
2016-11-09
This paper employs a three-stage approach to estimate low carbon economy efficiency in the largest twenty CO₂ emitting countries from 2000 to 2012. The approach includes the following three stages: (1) use of a data envelopment analysis (DEA) model with undesirable output to estimate the low carbon economy efficiency and calculate the input and output slacks; (2) use of a stochastic frontier approach to eliminate the impacts of external environment variables on these slacks; (3) re-estimation of the efficiency with adjusted inputs and outputs to reflect the capacity of the government to develop a low carbon economy. The results indicate that the low carbon economy efficiency performances in these countries had worsened during the studied period. The performances in the third stage are larger than that in the first stage. Moreover, in general, low carbon economy efficiency in Annex I countries of the United Nations Framework Convention on Climate Change (UNFCCC) is better than that in Non-Annex I countries. However, the gap of the average efficiency score between Annex I and Non-Annex I countries in the first stage is smaller than that in the third stage. It implies that the external environment variables show greater influence on Non-Annex I countries than that on Annex I countries. These external environment variables should be taken into account in the transnational negotiation of the responsibility of promoting CO₂ reductions. Most importantly, the developed countries (mostly in Annex I) should help the developing countries (mostly in Non-Annex I) to reduce carbon emission by opening or expanding the trade, such as encouraging the import and export of the energy-saving and sharing emission reduction technology.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-25
... functions. List of Subjects in 32 CFR Part 706 Marine safety, Navigation (water), and Vessels. For the... Distance in meters of forward masthead light below minimum Vessel Number required height. Sec. 2(a)(i... meters meters; rule meters; 2(K) in meters 2(K) 3(b) annex 1 21(c) annex 1 annex 1 * * * * * * * USS...
ATI SAA Annex 3 Button Tensile Test Report I
NASA Technical Reports Server (NTRS)
Tang, Henry H.
2013-01-01
This report documents the results of a study carried out under Splace Act Agreement SAA-EA-10-004 between the National Aeronautics and Space Administration (NASA) and Astro Technology Incorpporated (ATI). NASA and ATI have entered into this agreement to collaborate on the development of technologies that can benefit both the US government space programs and the oil and gas industry. The report documents the results of a test done on an adnesive system for attaching new monitoring sensor devices to pipelines under Annex III of SAA-EA-10-004: "Proof-of-Concept Design and Testing of a Post Installed Sensing Device on Subsea Risers and Pipelines". The tasks of Annex III are to design and test a proof-of-concept sensing device for in-situ installation on pipelines, risers, or other structures deployed in deep water. The function of the sensor device is to measure various signals such as strain, stress and temperature. This study complements the work done, in Annex I of the SAA, on attaching a fiber optic sensing device to pipe via adhesive bonding. Both Annex I and Annex III studies were conducted in the Crew and Thermal System Division (CTSD) at the Johnson Space Center (JSC) in collaboration with ATI.
Application of programmable logic controllers to space simulation
NASA Technical Reports Server (NTRS)
Sushon, Janet
1992-01-01
Incorporating a state-of-the-art process control and instrumentation system into a complex system for thermal vacuum testing is discussed. The challenge was to connect several independent control systems provided by various vendors to a supervisory computer. This combination will sequentially control and monitor the process, collect the data, and transmit it to color a graphic system for subsequent manipulation. The vacuum system upgrade included: replacement of seventeen diffusion pumps with eight cryogenic pumps and one turbomolecular pump, replacing a relay based control system, replacing vacuum instrumentation, and upgrading the data acquisition system.
Vroblesky, Don A.; Joshi, Manish; Morrell, Jeff; Peterson, J.E.
2003-01-01
During March-April 2002, the U.S. Geological Survey, Earth Tech, and EA Engineering, Science, and Technology, Inc., in cooperation with the Air Force Center for Environmental Excellence, tested diffusion samplers at Andersen Air Force Base, Guam. Samplers were deployed in three wells at the Main Base and two wells at Marianas Bonins (MARBO) Annex as potential ground-water monitoring alternatives. Prior to sampler deployment, the wells were tested using a borehole flowmeter to characterize vertical flow within each well. Three types of diffusion samplers were tested: passive diffusion bag (PDB) samplers, dialysis samplers, and nylon-screen samplers. The primary volatile organic compounds (VOCs) tested in ground water at Andersen Air Force Base were trichloroethene and tetrachloroethene. In most comparisons, trichloroethene and tetrachloroethene concentrations in PDB samples closely matched concentrations in pumped samples. Exceptions were in wells where the pumping or ambient flow produced vertical translocation of water in a chemically stratified aquifer. In these wells, PDB samplers probably would be a viable alternative sampling method if they were placed at appropriate depths. In the remaining three test wells, the trichloroethene or tetrachloroethene concentrations obtained with the diffusion samplers closely matched the result from pumped sampling. Chloride concentrations in nylon-screen samplers were compared with chloride concentrations in dialysis and pumped samples to test inorganic-solute diffusion into the samplers across a range of concentrations. The test showed that the results from nylon-screen samplers might have underestimated chloride concentrations at depths with elevated chloride concentrations. The reason for the discrepancy in this investigation is unknown, but may be related to nylon-screen-mesh size, which was smaller than that used in previous investigations.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-15
... safety, Navigation (water), and Vessels. For the reasons set forth in the preamble, amend part 706 of... sides stern in hull in forward light in rule 21(a) rule 21(b) rule 21(c) in meters meters; rule meters; 2(k) meters 2(k) 3(b) Annex 1 21(c) Annex 1 Annex 1 * * * * * * * USS SOMERSET LPD 25 1.64 below...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-30
... CFR Part 706 Marine safety, Navigation (water), and Vessels. For the reasons set forth in the preamble... stern in above hull in light in meters 2(k) Annex rule 21(a) rule 21(b) rule 21(c) in meters 3(b) meters; rule meters; 2(k) 1 Annex 1 21(c) Annex 1 * * * * * * * USS ANCHORAGE LPD 23 1.19 below...
33 CFR 151.53 - Special areas for Annex V of MARPOL 73/78.
Code of Federal Regulations, 2013 CFR
2013-07-01
....53 Special areas for Annex V of MARPOL 73/78. (a) For the purposes of §§ 151.51 through 151.77, the special areas are the Mediterranean Sea area, the Baltic Sea area, the Black Sea area, the Red Sea area... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Special areas for Annex V of...
33 CFR 151.53 - Special areas for Annex V of MARPOL 73/78.
Code of Federal Regulations, 2012 CFR
2012-07-01
....53 Special areas for Annex V of MARPOL 73/78. (a) For the purposes of §§ 151.51 through 151.77, the special areas are the Mediterranean Sea area, the Baltic Sea area, the Black Sea area, the Red Sea area... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Special areas for Annex V of...
33 CFR 151.53 - Special areas for Annex V of MARPOL 73/78.
Code of Federal Regulations, 2010 CFR
2010-07-01
....53 Special areas for Annex V of MARPOL 73/78. (a) For the purposes of §§ 151.51 through 151.77, the special areas are the Mediterranean Sea area, the Baltic Sea area, the Black Sea area, the Red Sea area... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Special areas for Annex V of...
2012-11-01
Urban Area Recovery Planning with CBR Hazards: Lessons Learned from Seattle and Denver 16 THE PUGET SOUND CATASTROPHIC DISASTER COORDINATION...PLAN – TRANSPORTATION RECOVERY ANNEX The Puget Sound Transportation Recovery Annex supplements the Puget Sound Regional Catastrophic Coordination... Puget Sound Region after a catastrophic incident. This Annex addresses transportation issues in Island, King, Kitsap, Mason, Pierce, Skagit, Snohomish
Selecting laser eye protectors - a helping hand
NASA Astrophysics Data System (ADS)
Gappenach, Catherine; Krüger, Jörg; Offenhäuser, Friedrich; Pintaske, Sabine; Krauß, Hans-Joachim
2015-10-01
The European laser safety standards EN 207, EN 208, and EN 12254 each contain an annex B, which serves as a guidance for the selection of products. These annexes are informative only and are therefore not binding. As there are a variety of hazard scenarios, it is not recommended to change these annexes to a normative status, through which they would become mandatory. Instead, it is recommended to allow users to apply their own skills and know-how in selecting appropriate products, justifying where and why they deviate from the guidance in the standards. This paper explains the background on which the guidance for selection in the annexes of the standards is based and shows physically meaningful leeway.
Olsen, C L; Turner, D S; Iravani, M; Waxman, K; Selam, J L; Charles, M A
1995-01-01
To evaluate the roles of 1) abdominal radiography, 2) a pressure diagnostic procedure (PDP) using a standardized diluent infusion into the catheter sideport, and 3) radiocontrast imaging of the catheter lumen as procedures for diagnosing catheter malfunction in diabetic patients implanted with a programmable intraperitoneal infusion device. Sixteen type I diabetic patients implanted with Infusaid programmable intraperitoneal insulin pumps were studied. The ability of the above three procedures to assist diagnosis of catheter malfunction and distinguish between occlusion and catheter breakage was retrospectively analyzed. Glycated hemoglobin was measured to determine the clinical importance of catheter malfunctions and decreases in pump flow due to insulin aggregation in the pump chamber. Mean glycated hemoglobin levels increased significantly from 8.0 +/- 0.3 to 9.0 +/- 0.4% (P < 0.05) before and after catheter malfunction, but not during pump flow slowdowns. Mean peak pressure during PDP was 1.96 +/- 0.14 psi (P < 0.01 vs. normal) in reversibly occluded catheters and 1.86 +/- 0.35 psi (P < 0.05 vs. normal) in broken catheters, compared with 1.32 +/- 0.23 psi in normal catheters. Decay times during PDP were > 50 s for both reversibly occluded and broken catheters (P < 0.001 vs. normal of 3.6 +/- 0.82 s). Abdominal radiographs and sideport injections of contrast material were used to distinguish the types of broken catheters. Catheter breakage and occlusion are complications in implantable insulin infusion systems and result in metabolic deterioration. The presence of a sideport allows pressure data and radiographic procedures to assist in determining the cause of catheter malfunction. A diagnostic algorithm was generated to improve efficiency in investigating catheter problems.
Design of a large magnetic-bearing turbomolecular pump for NET
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bernhardt, K.H.; Conrad, A.; Dinner, P.J.
1988-09-01
The feasibility of development of large vacuum components for operation in fusion machines have been investigated in the framework of the European Fusion Technology Programme. The requirements and the results of the feasibility study for the large turbomolecular pump units (TMP) are presented. Design parameters for single flow 50.000 l/s TMP and a double flow 15.000 and a 50.000 l/s TMP have been compared.
2014-03-14
NUMBER FA8201-09-D-0002 Overhaul Complex at Little Mountain Test Annex, Utah 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S...AND ADDRESS(ES) 8. PERFORMING ORGANIZATION REPORT NUMBER Streamline Consulting, LLC 1713 N. Sweetwater Lane Farmington, Utah 84025...Hill Air Force Base (AFB) proposes to construct a new emergency power unit overhaul complex at Little Mountain Test Annex, Utah . Buildings 2005
The U.S. fulfills its GLWQA commitments through federal programs and in coordination or consultation with other levels of U.S. government and the public. Annexes coordinate action on specific environmental issues.
Beyond 'dangerous' climate change: emission scenarios for a new world.
Anderson, Kevin; Bows, Alice
2011-01-13
The Copenhagen Accord reiterates the international community's commitment to 'hold the increase in global temperature below 2 degrees Celsius'. Yet its preferred focus on global emission peak dates and longer-term reduction targets, without recourse to cumulative emission budgets, belies seriously the scale and scope of mitigation necessary to meet such a commitment. Moreover, the pivotal importance of emissions from non-Annex 1 nations in shaping available space for Annex 1 emission pathways received, and continues to receive, little attention. Building on previous studies, this paper uses a cumulative emissions framing, broken down to Annex 1 and non-Annex 1 nations, to understand the implications of rapid emission growth in nations such as China and India, for mitigation rates elsewhere. The analysis suggests that despite high-level statements to the contrary, there is now little to no chance of maintaining the global mean surface temperature at or below 2°C. Moreover, the impacts associated with 2°C have been revised upwards, sufficiently so that 2°C now more appropriately represents the threshold between 'dangerous' and 'extremely dangerous' climate change. Ultimately, the science of climate change allied with the emission scenarios for Annex 1 and non-Annex 1 nations suggests a radically different framing of the mitigation and adaptation challenge from that accompanying many other analyses, particularly those directly informing policy.
Rand E. Eads; Mark R. Boolootian; Steven C. [Inventors] Hankin
1987-01-01
Abstract - A programmable calculator is connected to a pumping sampler by an interface circuit board. The calculator has a sediment sampling program stored therein and includes a timer to periodically wake up the calculator. Sediment collection is controlled by a Selection At List Time (SALT) scheme in which the probability of taking a sample is proportional to its...
A sophisticated programmable miniaturised pump for insulin delivery.
Klein, J C; Slama, G
1980-09-01
We have conceived a truly pre-programmable infusion system usable for intravenous administration of insulin in diabetic subjects. The original system has been built into a small, commercially available, syringe-pump of which only the case and the mechanical parts have been kept. The computing until has a timer, a programmable memory of 512 words by 8 bits and a digital-to-frequency converter to run the motor which drives the syringe. The memory contains 8 profiles of insulin injections stored in digital form over 64 words. Each profile is selected by the patient before eating according to the carbohydrate content of the planned meal and last about two hours, starting from and returning to the basal rate of insulin, at which it remains until next profile selection. Amount, profiles and duration of insulin injection are either mean values deduced from previous studies with a closed-loop artificial pancreas or personally fitted values; they are stored in an instantly replaceable memory cell. This device allows the patient to choose the time, nature and amount of his food intake.
2017-02-13
those from whom he derives his true power--the Russian people. Driven to make Russia a great power again, I argue that Putin’s decision to invade...strategically valuable piece of terrain. While undoubtedly seeking to influence Kiev’s strategic decision - making , prior to the 2014 annexation, Putin...inhabited by ethnic kin with its motherland. Putin’s decision to annex Crimea in 2014 was in part motivated by, and rationalized through
Saleh, Tawfik A; Abulkibash, A M; Ibrahim, Atta E
2012-04-01
A simple and fast-automated method was developed and validated for the assay of promethazine hydrochloride in pharmaceutical formulations, based on the oxidation of promethazine by cerium in an acidic medium. A portable system, consisting of a programmable syringe pump connected to a potentiometer, was constructed. The developed change in potential during promethazine oxidation was monitored. The related optimum working conditions, such as supporting electrolyte concentration, cerium(IV) concentration and flow rate were optimized. The proposed method was successfully applied to pharmaceutical samples as well as synthetic ones. The obtained results were realized by the official British pharmacopoeia (BP) method and comparable results were obtained. The obtained t-value indicates no significant differences between the results of the proposed and BP methods, with the advantages of the proposed method being simple, sensitive and cost effective.
Murie, Jill; Allen, Jane; Simmonds, Ray; de Wet, Carl
2012-01-01
Many patients unnecessarily receive proton-pump inhibitor (PPI) drugs long term with significant financial and safety implications. Educating, empowering and supporting patients to self-manage their symptoms can lead to significant and sustained reductions in PPI prescribing. We aimed to implement a programme to reduce inappropriate PPI prescribing. Eligible patients in one general medical practice in rural Scotland were invited for participation between November 2008 and February 2010. Patients attended special nurse advisor clinics, completed dyspepsia questionnaires, received information, formulated self-management plans and were offered flexible support. Of the study population, 437/2883 (15%) were prescribed PPIs. Of these, 166 (38%) were judged eligible for participation. After 12 months, 138/157 (83%) had reduced or stopped their PPIs, while 19/157 (11%) had reverted. The estimated annual net saving in the prescribing budget was ?3180.67. Self-reported understanding of symptom self-management increased from 6/20 (30%) to 18/20 (90%) patients after participation in the programme. A patient-centred programme delivered by a specialist nurse significantly reduced PPI prescribing with financial and potential therapeutic benefits. The vast majority of eligible patients were able to 'step down and off' or 'step off' PPI use after 12 months without any complications or deteriorating symptom control. Further research with larger cohorts of practices and patients is needed to develop a feasible, acceptable and effective programme if similar benefits are to be achieved for primary care in general.
Screw-actuated displacement micropumps for thermoplastic microfluidics.
Han, J Y; Rahmanian, O D; Kendall, E L; Fleming, N; DeVoe, D L
2016-10-05
The fabrication of on-chip displacement pumps integrated into thermoplastic chips is explored as a simple and low cost method for achieving precise and programmable flow control for disposable microfluidic systems. The displacement pumps consist of stainless steel screws inserted into threaded ports machined into a thermoplastic substrate which also serve as on-chip reagent storage reservoirs. Three different methods for pump sealing are investigated to enable high pressure flows without leakage, and software-defined control of multiple pumps is demonstrated in a self-contained platform using a compact and self-contained microcontroller for operation. Using this system, flow rates ranging from 0.5-40 μl min -1 are demonstrated. The pumps are combined with on-chip burst valves to fully seal multiple reagents into fabricated chips while providing on-demand fluid distribution in a downstream microfluidic network, and demonstrated for the generation of size-tunable water-in-oil emulsions.
An Overview of Insulin Pumps and Glucose Sensors for the Generalist
McAdams, Brooke H.; Rizvi, Ali A.
2016-01-01
Continuous subcutaneous insulin, or the insulin pump, has gained popularity and sophistication as a near-physiologic programmable method of insulin delivery that is flexible and lifestyle-friendly. The introduction of continuous monitoring with glucose sensors provides unprecedented access to, and prediction of, a patient’s blood glucose levels. Efforts are underway to integrate the two technologies, from “sensor-augmented” and “sensor-driven” pumps to a fully-automated and independent sensing-and-delivery system. Implantable pumps and an early-phase “bionic pancreas” are also in active development. Fine-tuned “pancreas replacement” promises to be one of the many avenues that offers hope for individuals suffering from diabetes. Although endocrinologists and diabetes specialists will continue to maintain expertise in this field, it behooves the primary care physician to have a working knowledge of insulin pumps and sensors to ensure optimal clinical care and decision-making for their patients. PMID:26742082
Self sufficient wireless transmitter powered by foot-pumped urine operating wearable MFC.
Taghavi, M; Stinchcombe, A; Greenman, J; Mattoli, V; Beccai, L; Mazzolai, B; Melhuish, C; Ieropoulos, I A
2015-12-10
The first self-sufficient system, powered by a wearable energy generator based on microbial fuel cell (MFC) technology is introduced. MFCs made from compliant material were developed in the frame of a pair of socks, which was fed by urine via a manual gaiting pump. The simple and single loop cardiovascular fish circulatory system was used as the inspiration for the design of the manual pump. A wireless programmable communication module, engineered to operate within the range of the generated electricity, was employed, which opens a new avenue for research in the utilisation of waste products for powering portable as well as wearable electronics.
NASA Astrophysics Data System (ADS)
Shortall, Ruth; Uihlein, Andreas
2017-04-01
Introduction The NER 300 programme, managed by the European Commission is one of the largest funding programmes for innovative low-carbon energy demonstration projects. NER 300 is so called because it is funded from the sale of 300 million emission allowances from the new entrants' reserve (NER) set up for the third phase of the EU emissions trading system (ETS). The programme aims to successfully demonstrate environmentally safe carbon capture and storage (CCS) and innovative renewable energy (RES) technologies on a commercial scale with a view to scaling up production of low-carbon technologies in the EU. Consequently, it supports a wide range of CCS and RES technologies (bioenergy, concentrated solar power, photovoltaics, geothermal, wind, ocean, hydropower, and smart grids). Funded projects and the role of geothermal projects for the programme In total, about EUR 2.1 billion have been awarded through the programme's 2 calls for proposals (the first awarded in December 2012, the second in July 2014). The programme has awarded around EUR 70 million funding to 3 geothermal projects in Hungary, Croatia and France. The Croatian geothermal project will enter into operation during 2017 the Hungarian in 2018, and the French in 2020. Knowledge Sharing Knowledge sharing requirements are built into the legal basis of the programme as a critical tool to lower risks in bridging the transition to large-scale production of innovative renewable energy and CCS deployment. Projects have to submit annually to the European Commission relevant knowledge gained during that year in the implementation of their project. The relevant knowledge is aggregated and disseminated by the European Commission to industry, research, government, NGO and other interest groups and associations in order to provide a better understanding of the practical challenges that arise in the important step of scaling up technologies and operating them at commercial scale. The knowledge sharing of the NER 300 programme should lead to better planning and faster introduction of low carbon technologies in the future. Content of the presentation The presentation will introduce the geothermal projects that have been awarded funding (see Annex), including their state-of-play. Insights and knowledge gained from the projects that have entered into operation will be shown and discussed. Furthermore, the presentation will provide an overview of the NER 300 programme.
2. View of south side (Art and Architecture Annex and ...
2. View of south side (Art and Architecture Annex and Communications Building visible to the left) - University of Idaho, YMCA Hut, Northeast corner of University Avenue & Line Street, Moscow, Latah County, ID
Most Recent Sampling Results for Annex III Building
Contains email from Scott Miller, US EPA to Scott Kramer. Subject: Most Recent Sampling Results for Annex III Building. (2:52 PM) and Gore(TM) Surveys Analytical Results U.S. Geological Survey, Montgomery, AL.
[EU-Cosmetics: timetables for the replacement of animal experiments].
Ruhdel, Irmela Wiltrud
2005-01-01
According to the 7(th) Amendment of the Cosmetics Directive the European Commission had to establish timetables for the phasing out of the various animal tests for the safety evaluation of ingredients used in cosmetics. However, the published timetables do not reflect the objectives of the 7(th) Amendment but contain longer deadlines for the ban on animal experiments of several endpoints. The European Commission also had to draw up a Directive for establishing an Annex IX that should list validated alternative methods which are not already listed in Annex V of the Dangerous Substances Directive. Although various alternative methods could have been listed in this Annex IX, the Commission published an empty table. From the point of view of the German Animal Welfare Federation amendments of the timetables and the Directive establishing Annex IX are urgently required. Additionally, the Commission has to provide optimal conditions for the replacement of alternative methods.
Final Report for Annex II--Assessment of Solar Radiation Resources In Saudi Arabia, 1998-2000
DOE Office of Scientific and Technical Information (OSTI.GOV)
Myers, D. R.; Wilcox, S. M.; Marion, W. F.
2002-04-01
The Final Report for Annex II - Assessment of Solar Radiation Resources in Saudi Arabia 1998-2000 summarizes the accomplishment of work performed, results achieved, and products produced under Annex II, a project established under the Agreement for Cooperation in the Field of Renewable Energy Research and Development between the Kingdom of Saudi Arabia and the United States. The report covers work and accomplishments from January 1998 to December 2000. A previous progress report, Progress Report for Annex II - Assessment of Solar Radiation Resources in Saudi Arabia 1993-1997, NREL/TP-560-29374, summarizes earlier work and technical transfer of information under the project.more » The work was performed in at the National Renewable Energy Laboratory (NREL) in Golden, Colorado, at the King Abdulaziz City for Science and Technology (KACST) in Riyadh, Saudi Arabia, and at selected weather stations of the Saudi Meteorological and Environmental Protection Administration (MEPA).« less
Experimental investigation on charcoal adsorption for cryogenic pump application
NASA Astrophysics Data System (ADS)
Scannapiego, Matthieu; Day, Christian
2017-12-01
Fusion reactors are generating energy by nuclear fusion between deuterium and tritium. In order to evacuate the high gas throughputs from the plasma exhaust, large pumping speed systems are required. Within the European Fusion Programme, the Karlsruhe Institute of Technology (KIT) has taken the lead to design a three-stage cryogenic pump that can provide a separation function of hydrogen isotopes from the remaining gases; hence limiting the tritium inventory in the machine. A primary input parameter for the detailed design of a cryopump is the sticking coefficient between the gas and the pumping surface. For this purpose, the so-called TIMO open panel pump experiment was conducted in the TIMO-2 test facility at KIT in order to measure pumping speeds on an activated carbon surface cooled at temperatures between 6 K and 22 K, for various pure gases and gas mixtures, under fusion relevant gas flow conditions, and for two different geometrical pump configurations. The influences of the panel temperature, the gas throughput and the intake gas temperature on the pumping speed have been characterized, providing valuable qualitative results for the design of the three-stage cryopump. In a future work, supporting Monte Carlo simulations should allow for derivation of the sticking coefficients.
Technical data on new engineering products
NASA Astrophysics Data System (ADS)
1985-02-01
New grades of permanently magnetic materials; automatic digital radiolocator; bench winder; analog induction gauge; programmable pulse generator; portable defibrillators; pipe welders; two-component electromagnetic log; sulphur content analyzer; peristaltic pumps; function generators; welding manipulator; and tonsiometer are described.
Development of medical electronic devices in the APL space department
NASA Technical Reports Server (NTRS)
Newman, A. L.
1985-01-01
Several electronic devices for automatically correcting specific defects in a body's physiologic regulation and allowing approximately normal functioning are described. A self-injurious behavior inhibiting system (SIBIS) is fastened to the arm of a person with chronic self-injurious behavior patterns. An electric shock is delivered into the arm whenever the device senses above-threshold acceleration of the head such as occur with head-bangers. Sounding a buzzer tone with the shock eventually allows transference of the aversive stimulus to the buzzer so shocks are no longer necessary. A programmable implantable medication system features a solenoid pump placed beneath the skin and refueled by hypodermic needle. The pump functions are programmable and can deliver insulin, chemotherapy mixes and/or pain killers according to a preset schedule or on patient demand. Finally, an automatic implantible defibrillator has four electrodes attached directly to the heart for sensing electrical impulses or emitting them in response to cardiac fibrillation.
Saleh, Tawfik A.; Abulkibash, A.M.; Ibrahim, Atta E.
2011-01-01
A simple and fast-automated method was developed and validated for the assay of promethazine hydrochloride in pharmaceutical formulations, based on the oxidation of promethazine by cerium in an acidic medium. A portable system, consisting of a programmable syringe pump connected to a potentiometer, was constructed. The developed change in potential during promethazine oxidation was monitored. The related optimum working conditions, such as supporting electrolyte concentration, cerium(IV) concentration and flow rate were optimized. The proposed method was successfully applied to pharmaceutical samples as well as synthetic ones. The obtained results were realized by the official British pharmacopoeia (BP) method and comparable results were obtained. The obtained t-value indicates no significant differences between the results of the proposed and BP methods, with the advantages of the proposed method being simple, sensitive and cost effective. PMID:23960787
Development of cryosorption panels for cryopumps
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perinic, D.; Haas, H.; Mack, A.
1994-12-31
Liquid-helium cooled cryosorption panels have been developed in Karlsruhe for plasma exhaust pumping in tokamaks. A variety of material combinations (sorbent/bonding/substrate) and various coating techniques have been compared in an extensive testing programme. A technology suitable for machine coating of large surfaces has been developed applying injector nozzles for spraying of bonding and sorbent materials. Inorganic cements have been selected for bonding activated carbon or molecular sieve particles, 10 {mu}m to 2 mm grain size, to metal substrates. The cryosorption panels prepared in this way are capable of pumping simulated tokamak exhaust gas mixtures including deuterium, helium and impurities atmore » pumping speeds of up to 8 L/(s cm{sup 2}) and pumping pressures < 10{sup {minus}2} mbar. In this paper the development of the coating technology and some results of panel testing are described.« less
Punch Card Programmable Microfluidics
Korir, George; Prakash, Manu
2015-01-01
Small volume fluid handling in single and multiphase microfluidics provides a promising strategy for efficient bio-chemical assays, low-cost point-of-care diagnostics and new approaches to scientific discoveries. However multiple barriers exist towards low-cost field deployment of programmable microfluidics. Incorporating multiple pumps, mixers and discrete valve based control of nanoliter fluids and droplets in an integrated, programmable manner without additional required external components has remained elusive. Combining the idea of punch card programming with arbitrary fluid control, here we describe a self-contained, hand-crank powered, multiplex and robust programmable microfluidic platform. A paper tape encodes information as a series of punched holes. A mechanical reader/actuator reads these paper tapes and correspondingly executes operations onto a microfluidic chip coupled to the platform in a plug-and-play fashion. Enabled by the complexity of codes that can be represented by a series of holes in punched paper tapes, we demonstrate independent control of 15 on-chip pumps with enhanced mixing, normally-closed valves and a novel on-demand impact-based droplet generator. We demonstrate robustness of operation by encoding a string of characters representing the word “PUNCHCARD MICROFLUIDICS” using the droplet generator. Multiplexing is demonstrated by implementing an example colorimetric water quality assays for pH, ammonia, nitrite and nitrate content in different water samples. With its portable and robust design, low cost and ease-of-use, we envision punch card programmable microfluidics will bring complex control of microfluidic chips into field-based applications in low-resource settings and in the hands of children around the world. PMID:25738834
Punch card programmable microfluidics.
Korir, George; Prakash, Manu
2015-01-01
Small volume fluid handling in single and multiphase microfluidics provides a promising strategy for efficient bio-chemical assays, low-cost point-of-care diagnostics and new approaches to scientific discoveries. However multiple barriers exist towards low-cost field deployment of programmable microfluidics. Incorporating multiple pumps, mixers and discrete valve based control of nanoliter fluids and droplets in an integrated, programmable manner without additional required external components has remained elusive. Combining the idea of punch card programming with arbitrary fluid control, here we describe a self-contained, hand-crank powered, multiplex and robust programmable microfluidic platform. A paper tape encodes information as a series of punched holes. A mechanical reader/actuator reads these paper tapes and correspondingly executes operations onto a microfluidic chip coupled to the platform in a plug-and-play fashion. Enabled by the complexity of codes that can be represented by a series of holes in punched paper tapes, we demonstrate independent control of 15 on-chip pumps with enhanced mixing, normally-closed valves and a novel on-demand impact-based droplet generator. We demonstrate robustness of operation by encoding a string of characters representing the word "PUNCHCARD MICROFLUIDICS" using the droplet generator. Multiplexing is demonstrated by implementing an example colorimetric water quality assays for pH, ammonia, nitrite and nitrate content in different water samples. With its portable and robust design, low cost and ease-of-use, we envision punch card programmable microfluidics will bring complex control of microfluidic chips into field-based applications in low-resource settings and in the hands of children around the world.
GENERAL INTERIOR VIEW AT THE WEST ANNEX LOOKING NORTH FROM ...
GENERAL INTERIOR VIEW AT THE WEST ANNEX LOOKING NORTH FROM COLUMN LINE AA-45 SHOWING SECURITY BALCONY TO THE RIGHT. - Offutt Air Force Base, Glenn L. Martin-Nebraska Bomber Plant, Building D, Peacekeeper Drive, Bellevue, Sarpy County, NE
Role of Smart Grids in Integrating Renewable Energy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Speer, B.; Miller, M.; Schaffer, W.
2015-05-27
This report was prepared for the International Smart Grid Action Network (ISGAN), which periodically publishes briefs and discussion papers on key topics of smart grid development globally. The topic of this report was selected by a multilateral group of national experts participating in ISGAN Annex 4, a working group that aims to produce synthesis insights for decision makers. This report is an update of a 2012 ISGAN Annex 4 report entitled “Smart Grid Contributions to Variable Renewable Resource Integration.” That report and other past publications of ISGAN Annexes can be found at www.iea-isgan.org and at www.cleanenergysolutions.org.
New Whole-House Case Study: William Ryan Homes, Tampa, Florida
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
The builder worked with Consortium for Advanced Residential Buildings to design HERS-65 homes with energy-efficient heat pumps and programmable thermostats with humidity controls, foam-filled concrete block walls, draining house wrap, and airsealed kneewalls.
Bayindir, Ramazan; Cetinceviz, Yucel
2011-04-01
This paper describes a water pumping control system that is designed for production plants and implemented in an experimental setup in a laboratory. These plants contain harsh environments in which chemicals, vibrations or moving parts exist that could potentially damage the cabling or wires that are part of the control system. Furthermore, the data has to be transferred over paths that are accessible to the public. The control systems that it uses are a programmable logic controller (PLC) and industrial wireless local area network (IWLAN) technologies. It is implemented by a PLC, an communication processor (CP), two IWLAN modules, and a distributed input/output (I/O) module, as well as the water pump and sensors. Our system communication is based on an Industrial Ethernet and uses the standard Transport Control Protocol/Internet Protocol for parameterisation, configuration and diagnostics. The main function of the PLC is to send a digital signal to the water pump to turn it on or off, based on the tank level, using a pressure transmitter and inputs from limit switches that indicate the level of the water in the tank. This paper aims to provide a convenient solution in process plants where cabling is not possible. It also has lower installation and maintenance cost, provides reliable operation, and robust and flexible construction, suitable for industrial applications. Copyright © 2010 ISA. Published by Elsevier Ltd. All rights reserved.
Kyoto-Related Fossil-Fuel CO2 Emission Totals (1990 - 2009) (Version 2012) (Updated 01/16/2013)
Marland, Greg [Appalachian State University, Boone, NC (USA); Boden, Thomas A. [Carbon Dioxide Information Analysis Center (CDIAC), Oak Ridge National Laboratory (ORNL), Oak Ridge, TN
2013-01-16
This table shows the total of CO2 emissions from fossil-fuel use and cement manufacture for those countries listed in Annex B of the Kyoto Protocol and for those countries not listed in Annex B. In keeping with the convention of the IPCC methodology for calculating national greenhouse gas emissions, emissions from international bunker fuels (fuels used in international commerce) are not included in the country totals but are shown separately under the country group in which final fuel loading occurred. Note, that the list of countries in Annex B of the Kyoto Protocol differs from the list of countries in Annex I of the Framework Convention on Climate Change by the addition of Croatia, Liechtenstein, Monaco, and Slovenia and the removal of Belarus and Turkey. We have estimated emissions for 1990 and 1991 from the republics that were formerly part of the USSR and of Yugoslavia by taking total emissions from the USSR (and Yugoslavia) for 1990 and 1991 and distributing them among the new republics in the same ratio as emissions from those republics in 1992. Because of minor differences in the method of estimating the global total of emissions and the national totals of emissions, the sum of emissions from all countries produces a number that is less than the global total by about 2%. Consequently we have inflated the sum of emissions from all Annex B countries and the sum of emissions from all non-Annex B countries by about 2% (the value differs from year to year) so that the sum of the two values plus emissions from bunker fuels is equal to our best estimate of the global total of emissions.
Heat Stress Mitigation for Leopard 2C Tank Crew
2007-05-01
25 Annex B Scale of Thermal Comfort Ratings...18 Figure 10. Subjective ratings of whole body thermal comfort . See Annex B...was estimated from changes in dressed weight. Subjects were asked to provide two subjective ratings of their thermal comfort generally every 15
78 FR 23773 - Chemical Transportation Advisory Committee
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-22
... Working Groups will meet on May 7 through 9, 2013, in Arlington, VA, to discuss marine transportation of... marine transportation of hazardous materials. The Committee advises, consults with, and makes... of Pollution from Ships (MARPOL) Annex II b. Requirements for Third-Party Surveyors of MARPOL Annex...
Teenagers with diabetes: self-management education and training on a big schooner.
Viklund, Gunnel E; Rudberg, Susanne; Wikblad, K F
2007-12-01
The aims of this study are to evaluate whether diabetic teenagers participating in a group educational programme, 'the schooner programme', differ from non-participants in attitudes towards diabetes and self-care, and to evaluate the impact on the attitudes, HbA1c and treatment of the programme. Ninety teenagers aged 14-18 years attended the programme. Attitudes towards diabetes and self-care were measured with a validated questionnaire. Medical data were collected from the medical records. The participants reported more positive attitudes towards diabetes and self-care and more frequent contacts with others with diabetes monitored blood glucose more often and felt less disturbed by diabetes than non-participants. The programme had positive impact on attitudes towards diabetes. There was no change in HbA1c, but the use of insulin pumps was more frequent among participants after the programme. To get teenagers attracted to group education, the diabetes care team needs to influence them towards more positive attitudes.
Code of Federal Regulations, 2010 CFR
2010-01-01
... limited to, railcars, trucks, trailers, semitrailers, and intermodal freight containers that have an.... Perishable foodstuffs means the quick deep-frozen and frozen food products listed in Annex 2, and the chilled food products listed in Annex 3 to the ATP. Reference equipment means a unit of equipment which has...
2018-03-28
SLS INTERTANK TEST ARTICLE IS ATTACHED TO CROSSHEAD OF LOAD TEST ANNEX, BLDG. 4619, AND REMOVED FROM BED OF KMAG TRANSPORTER. Matt Cash conducts tag up meeting before lift of ITA from KMAG transporter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1985-12-01
MARPOL was developed to minimize accidental and operational pollution from ships carrying noxious liquid substances in bulk. Accidental pollution could result from a collision, a grounding, or an overflow of a cargo tank. Operational pollution results from the disposal of cargo tank washings. Major amendments were made to the original Annex II by the International Maritime Organization. The United States and other States party to MARPOL will implement Annex II, as amended, on April 7, 1987. Implementation will affect seagoing ships transporting noxious liquid substances to and from such ships. The attached documents contain internationally agreed requirements, interpretations, and guidelinesmore » necessary for the implementation of Annex II. The documents attached include: (1) MARPOL Annex II as amended by amendments adopted by the twenty-second session of the IMO Marine Environment Protection Committee; (2) Unified Interpretations of Annex II; (3) Standards for the Procedures and Arrangements for the Discharge of Noxious Liquid Substances; (4) Ammendments to the Bulk Chemical Code and the International Bulk Chemical Code to include marine pollution concerns; (5) Guidelines on the Provision of Adequate Reception Facilities in Ports, Part II (Noxious Liquid Substances). The contents of these documents are being placed in regulations. The purpose of this document is to give members of the interested public advance notification of impending regulations.« less
NASA Astrophysics Data System (ADS)
Uihlein, Andreas; Salto Saura, Lourdes; Sigfusson, Bergur; Lichtenvort, Kerstin; Gagliardi, Filippo
2015-04-01
Introduction The NER 300 programme, managed by the European Commission is one of the largest funding programmes for innovative low-carbon energy demonstration projects. NER 300 is so called because it is funded from the sale of 300 million emission allowances from the new entrants' reserve (NER) set up for the third phase of the EU emissions trading system (ETS). The programme aims to successfully demonstrate environmentally safe carbon capture and storage (CCS) and innovative renewable energy (RES) technologies on a commercial scale with a view to scaling up production of low-carbon technologies in the EU. Consequently, it supports a wide range of CCS and RES technologies (bioenergy, concentrated solar power, photovoltaics, geothermal, wind, ocean, hydropower, and smart grids). Funded projects and the role of geothermal projects for the programme In total, about EUR 2.1 billion have been awarded to 39 projects through the programme's 2 calls for proposals (the first awarded in December 2012, the second in July 2014). The programme has awarded around 70 mEUR funding to 3 geothermal projects in Hungary, Croatia and France (see Annex). The Hungarian geothermal project awarded funding under the first call will enter into operation at the end of 2015 and the rest are expected to start in 2016 (HR) and in 2018 (FR), respectively. Knowledge Sharing Knowledge sharing requirements are built into the legal basis of the programme as a critical tool to lower risks in bridging the transition to large-scale production of innovative renewable energy and CCS deployment. Projects have to submit annually to the European Commission relevant knowledge gained during that year in the implementation of their project. The relevant knowledge is aggregated and disseminated by the European Commission to industry, research, government, NGO and other interest groups and associations in order to provide a better understanding of the practical challenges that arise in the important step of scaling up technologies and operating them at commercial scale. The knowledge sharing of the NER 300 programme should lead to better planning and faster introduction of low carbon technologies in the future. Content of the presentation The presentation will introduce the geothermal projects that have been awarded funding, including their state-of-play. Insights and knowledge gained from the projects that have entered into operation will be shown and discussed. Furthermore, the presentation will provide an overview of the NER 300 programme.
40 CFR Table 4 to Subpart Zzzz of... - Requirements for Performance Tests
Code of Federal Regulations, 2012 CFR
2012-07-01
... D6348-03,c provided in ASTM D6348-03 Annex A5 (Analyte Spiking Technique), the percent R must be greater... ASTM D6348-03,c provided in ASTM D6348-03 Annex A5 (Analyte Spiking Technique), the percent R must be...
40 CFR Table 4 to Subpart Zzzz of... - Requirements for Performance Tests
Code of Federal Regulations, 2011 CFR
2011-07-01
... D6348-03,c provided in ASTM D6348-03 Annex A5 (Analyte Spiking Technique), the percent R must be greater... ASTM D6348-03,c provided in ASTM D6348-03 Annex A5 (Analyte Spiking Technique), the percent R must be...
Code of Federal Regulations, 2011 CFR
2011-07-01
...., Public Law 104-227, the Antarctic Science, Tourism, and Conservation Act of 1996. Annex I refers to Annex... pursuant to Article IX(1) of the Treaty. Antarctica means the Antarctic Treaty area; i.e., the area south... area for which advance notification is required under Paragraph 5 of Article VII of the Treaty. Impact...
47 CFR 80.1113 - Transmission of a distress alert.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Procedures for Distress and Safety Communications § 80.1113 Transmission of a distress alert. (a) The... Selective-Calling Equipment in the Maritime Mobile Service,” with Annexes 1 through 5, 2004, as specified in... Annexes 1 through 5, 2004, are incorporated by reference. The Director of the Federal Register approves...
47 CFR 80.1113 - Transmission of a distress alert.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Procedures for Distress and Safety Communications § 80.1113 Transmission of a distress alert. (a) The... Selective-Calling Equipment in the Maritime Mobile Service,” with Annexes 1 through 5, 2004, as specified in... Annexes 1 through 5, 2004, are incorporated by reference. The Director of the Federal Register approves...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Administration DEPARTMENT OF JUSTICE (CONTINUED) PROCEDURES FOR THE ADMINISTRATION OF SECTION 5 OF THE VOTING RIGHTS ACT OF 1965, AS AMENDED Determinations by the Attorney General § 51.61 Annexations. (a) Coverage... deannexations only as they pertain to voting. (b) Section 5 review. It is the practice of the Attorney General...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Administration DEPARTMENT OF JUSTICE (CONTINUED) PROCEDURES FOR THE ADMINISTRATION OF SECTION 5 OF THE VOTING RIGHTS ACT OF 1965, AS AMENDED Determinations by the Attorney General § 51.61 Annexations. (a) Coverage... voting. (b) Section 5 review. It is the practice of the Attorney General to review all of a jurisdiction...
Yue, Baohua; Brendel, Ron; Lukitsch, Amelia; Prentice, Thomas; Doty, Brian
2017-06-01
Commercial baclofen formulations used with infusion pumps are available at therapeutic concentrations of 0.5-2.0 mg/mL. However, patients who receive higher daily doses of baclofen may benefit from products with greater baclofen concentrations since their refill frequency would be reduced (up to a maximum of 180 days). We evaluated baclofen solubility, baclofen 3 mg/mL intrathecal (IT) formulation stability, and chemical and physical compatibility with Medtronic SynchroMed ® II and Codman Medstream ® programmable IT infusion pumps. For solubility evaluations, baclofen powder was dissolved into isotonic saline and tested at 5°C, 25°C, and 40°C. To demonstrate drug product stability, both physical and chemical stability attributes of baclofen 3 mg/mL in prefilled syringes were evaluated over 36 months with storage at 25°C. For a simulated in-use stability (compatibility) study, a 3 mg/mL baclofen IT formulation was placed in SynchroMed II and Codman Medstream pumps at 37ºC for study durations, and evaluated at different flow rates. Pump effluent was collected at various times and analyzed by high-performance liquid chromatography for baclofen content. On completion of the in-use stability study, pumps exposed to baclofen 3 mg/mL were dissected and visually evaluated for signs of deterioration. Baclofen solubility was found to be 3.2 mg/mL at 5°C, 3.6 mg/mL at 25°C, and 3.9 mg/mL at 40°C. During the 36-month stability study of prefilled syringes stored at 25°C, baclofen content remained unchanged and no precipitation was observed. The simulated in-use pump study performed at 37ºC showed that a baclofen 3 mg/mL IT formulation was stable at different flow rates and throughout different expected residence times for both pump models. Components from both pumps exhibited no noticeable deterioration after exposure to the 3 mg/mL formulation. Baclofen 3 mg/mL IT formulation was stable during long-term storage at 25°C and remained stable under conditions matching those encountered in clinical practice (37°C). © 2016 International Neuromodulation Society.
Implantation of programmable infusion pumps for insulin delivery in type I diabetic patients.
Walter, H; Günther, A; Kronski, D; Flaschenträger, T; Mehnert, H
1989-06-01
Five type I diabetic patients were followed prospectively during treatment with continuous subcutaneous insulin infusion by externally worn pumps and during the first 12 months after implantation of a remote-controlled insulin infusion device (ID1, Siemens AG). Stabilized insulin (Hoe 21 GH, Hoechst AG) was infused intravenously in two and intraperitoneally in three patients. Total observation time was 47.2 patient-months after implantation. Two devices had to be explanted prematurely, one because of a technical failure after 101 days, one due to a skin necrosis over the implant after 236 days. HbA1, frequency of hypoglycemia, total insulin dose, and basal rate infusion did not change after implantation. There was a reduction in the insulin antibodies 6 months after start of intravenous or intraperitoneal insulin delivery. Fasting plasma free insulin levels could be normalized only by intraperitoneal insulin infusion. Although a technical and a surgical problem was observed, our data show the successful implantation and clinical use of programmable dosing devices and stabilized insulin.
Plocková, J; Chmelík, J
2001-05-25
Gravitational field-flow fractionation (GFFF) utilizes the Earth's gravitational field as an external force that causes the settlement of particles towards the channel accumulation wall. Hydrodynamic lift forces oppose this action by elevating particles away from the channel accumulation wall. These two counteracting forces enable modulation of the resulting force field acting on particles in GFFF. In this work, force-field programming based on modulating the magnitude of hydrodynamic lift forces was implemented via changes of flow-rate, which was accomplished by a programmable pump. Several flow-rate gradients (step gradients, linear gradients, parabolic, and combined gradients) were tested and evaluated as tools for optimization of the separation of a silica gel particle mixture. The influence of increasing amount of sample injected on the peak resolution under flow-rate gradient conditions was also investigated. This is the first time that flow-rate gradients have been implemented for programming of the resulting force field acting on particles in GFFF.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-19
... Texts for Use in the International Conference on Harmonisation Regions; Annex 14 on Bacterial Endotoxins... ``Q4B Evaluation and Recommendation of Pharmacopoeial Texts for Use in the ICH Regions; Annex 14... Endotoxins Test General Chapter harmonized text from each of the three pharmacopoeias (United States...
7 CFR 3300.37 - Testing of a mechanical refrigerating appliance.
Code of Federal Regulations, 2011 CFR
2011-01-01
... THE SPECIAL EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF... appliance is intended, with classes being defined as in ATP, Annex 1, paragraph 3. (c) A report of each test shall be completed on a form corresponding to the pertinent test report model prescribed in ATP, Annex 1...
7 CFR 3300.37 - Testing of a mechanical refrigerating appliance.
Code of Federal Regulations, 2012 CFR
2012-01-01
... THE SPECIAL EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF... appliance is intended, with classes being defined as in ATP, Annex 1, paragraph 3. (c) A report of each test shall be completed on a form corresponding to the pertinent test report model prescribed in ATP, Annex 1...
7 CFR 3300.37 - Testing of a mechanical refrigerating appliance.
Code of Federal Regulations, 2014 CFR
2014-01-01
... THE SPECIAL EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF... appliance is intended, with classes being defined as in ATP, Annex 1, paragraph 3. (c) A report of each test shall be completed on a form corresponding to the pertinent test report model prescribed in ATP, Annex 1...
7 CFR 3300.37 - Testing of a mechanical refrigerating appliance.
Code of Federal Regulations, 2013 CFR
2013-01-01
... THE SPECIAL EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF... appliance is intended, with classes being defined as in ATP, Annex 1, paragraph 3. (c) A report of each test shall be completed on a form corresponding to the pertinent test report model prescribed in ATP, Annex 1...
Reframing the English Grammar Schools Debate
ERIC Educational Resources Information Center
Morris, Rebecca; Perry, Thomas
2017-01-01
In October 2015 the Department for Education (DfE) permitted a grammar school in Tonbridge, Kent, to open up an annexe in Sevenoaks, 10 miles away. Amidst claims that the annexe was essentially a new grammar school, the decision reignited an old debate about the value of academically-selective "grammar" schools in England. The intensity…
Mergers, Annexations, Dissolutions
ERIC Educational Resources Information Center
Russo, Alexander
2006-01-01
Consolidations come in all shapes and sizes, including mergers, annexations and dissolutions. They do not all take place under state mandate, however. A handful of districts consolidate every year in some states like Illinois that have large numbers of small districts, many of them dual districts that serve K-8 or 9-12 in the same geographic area.…
14 CFR Appendix B to Part 36 - Noise Levels for Transport Category and Jet Airplanes Under § 36.103
Code of Federal Regulations, 2014 CFR
2014-01-01
..., DEPARTMENT OF TRANSPORTATION AIRCRAFT NOISE STANDARDS: AIRCRAFT TYPE AND AIRWORTHINESS CERTIFICATION Pt. 36... Organization (ICAO) Annex 16, Environmental Protection, Volume I, Aircraft Noise, Third Edition, July 1993... (ICAO) Annex 16, Environmental Protection, Volume I, Aircraft Noise, Third Edition, July 1993, Amendment...
40 CFR 8.5 - Submission of environmental documents.
Code of Federal Regulations, 2013 CFR
2013-07-01
... environmental documentation meets the requirements of Article 8 and Annex I of the Protocol and the provisions... Article 8 and Annex I of the Protocol and the provisions of this part, the operator will have no further... and with the concurrence of the National Science Foundation, will inform the operator that EPA finds...
40 CFR 8.8 - Comprehensive environmental evaluation.
Code of Federal Regulations, 2014 CFR
2014-07-01
... evaluate the CEE to determine if the CEE meets the requirements under Article 8 and Annex I to the Protocol... operator, the EPA will inform the operator if EPA, with the concurrence of the National Science Foundation... Article 8 and Annex I of the Protocol and the provisions of this part. This notification will occur within...
40 CFR 8.6 - Preliminary environmental review.
Code of Federal Regulations, 2011 CFR
2011-07-01
... the obligations of Article 8 and Annex I of the Protocol. The EPA will provide its comments to the... of Article 8 and Annex I of the Protocol and the provisions of this part. This finding will be made with the concurrence of the National Science Foundation. If EPA does not provide such notice within...
40 CFR 8.6 - Preliminary environmental review.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the obligations of Article 8 and Annex I of the Protocol. The EPA will provide its comments to the... of Article 8 and Annex I of the Protocol and the provisions of this part. This finding will be made with the concurrence of the National Science Foundation. If EPA does not provide such notice within...
40 CFR 8.5 - Submission of environmental documents.
Code of Federal Regulations, 2010 CFR
2010-07-01
... environmental documentation meets the requirements of Article 8 and Annex I of the Protocol and the provisions... Article 8 and Annex I of the Protocol and the provisions of this part, the operator will have no further... and with the concurrence of the National Science Foundation, will inform the operator that EPA finds...
40 CFR 8.8 - Comprehensive environmental evaluation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... evaluate the CEE to determine if the CEE meets the requirements under Article 8 and Annex I to the Protocol... operator, the EPA will inform the operator if EPA, with the concurrence of the National Science Foundation... Article 8 and Annex I of the Protocol and the provisions of this part. This notification will occur within...
40 CFR 8.7 - Initial environmental evaluation.
Code of Federal Regulations, 2014 CFR
2014-07-01
... documentation requirements under Article 8 and Annex I to the Protocol and the provisions of this part or a CEE... documentation submitted does not meet the requirements of Article 8 and Annex I of the Protocol and the provisions of this part. This finding will be made with the concurrence of the National Science Foundation...
40 CFR 8.6 - Preliminary environmental review.
Code of Federal Regulations, 2013 CFR
2013-07-01
... the obligations of Article 8 and Annex I of the Protocol. The EPA will provide its comments to the... of Article 8 and Annex I of the Protocol and the provisions of this part. This finding will be made with the concurrence of the National Science Foundation. If EPA does not provide such notice within...
40 CFR 8.6 - Preliminary environmental review.
Code of Federal Regulations, 2012 CFR
2012-07-01
... the obligations of Article 8 and Annex I of the Protocol. The EPA will provide its comments to the... of Article 8 and Annex I of the Protocol and the provisions of this part. This finding will be made with the concurrence of the National Science Foundation. If EPA does not provide such notice within...
40 CFR 8.6 - Preliminary environmental review.
Code of Federal Regulations, 2014 CFR
2014-07-01
... the obligations of Article 8 and Annex I of the Protocol. The EPA will provide its comments to the... of Article 8 and Annex I of the Protocol and the provisions of this part. This finding will be made with the concurrence of the National Science Foundation. If EPA does not provide such notice within...
40 CFR 8.5 - Submission of environmental documents.
Code of Federal Regulations, 2014 CFR
2014-07-01
... environmental documentation meets the requirements of Article 8 and Annex I of the Protocol and the provisions... Article 8 and Annex I of the Protocol and the provisions of this part, the operator will have no further... and with the concurrence of the National Science Foundation, will inform the operator that EPA finds...
40 CFR 8.7 - Initial environmental evaluation.
Code of Federal Regulations, 2012 CFR
2012-07-01
... documentation requirements under Article 8 and Annex I to the Protocol and the provisions of this part or a CEE... documentation submitted does not meet the requirements of Article 8 and Annex I of the Protocol and the provisions of this part. This finding will be made with the concurrence of the National Science Foundation...
40 CFR 8.7 - Initial environmental evaluation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... documentation requirements under Article 8 and Annex I to the Protocol and the provisions of this part or a CEE... documentation submitted does not meet the requirements of Article 8 and Annex I of the Protocol and the provisions of this part. This finding will be made with the concurrence of the National Science Foundation...
40 CFR 8.5 - Submission of environmental documents.
Code of Federal Regulations, 2012 CFR
2012-07-01
... environmental documentation meets the requirements of Article 8 and Annex I of the Protocol and the provisions... Article 8 and Annex I of the Protocol and the provisions of this part, the operator will have no further... and with the concurrence of the National Science Foundation, will inform the operator that EPA finds...
40 CFR 8.7 - Initial environmental evaluation.
Code of Federal Regulations, 2013 CFR
2013-07-01
... documentation requirements under Article 8 and Annex I to the Protocol and the provisions of this part or a CEE... documentation submitted does not meet the requirements of Article 8 and Annex I of the Protocol and the provisions of this part. This finding will be made with the concurrence of the National Science Foundation...
40 CFR 8.5 - Submission of environmental documents.
Code of Federal Regulations, 2011 CFR
2011-07-01
... environmental documentation meets the requirements of Article 8 and Annex I of the Protocol and the provisions... Article 8 and Annex I of the Protocol and the provisions of this part, the operator will have no further... and with the concurrence of the National Science Foundation, will inform the operator that EPA finds...
40 CFR 8.7 - Initial environmental evaluation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... documentation requirements under Article 8 and Annex I to the Protocol and the provisions of this part or a CEE... documentation submitted does not meet the requirements of Article 8 and Annex I of the Protocol and the provisions of this part. This finding will be made with the concurrence of the National Science Foundation...
40 CFR 8.8 - Comprehensive environmental evaluation.
Code of Federal Regulations, 2013 CFR
2013-07-01
... evaluate the CEE to determine if the CEE meets the requirements under Article 8 and Annex I to the Protocol... operator, the EPA will inform the operator if EPA, with the concurrence of the National Science Foundation... Article 8 and Annex I of the Protocol and the provisions of this part. This notification will occur within...
40 CFR 8.8 - Comprehensive environmental evaluation.
Code of Federal Regulations, 2012 CFR
2012-07-01
... evaluate the CEE to determine if the CEE meets the requirements under Article 8 and Annex I to the Protocol... operator, the EPA will inform the operator if EPA, with the concurrence of the National Science Foundation... Article 8 and Annex I of the Protocol and the provisions of this part. This notification will occur within...
33 CFR 334.290 - Elizabeth River, Southern Branch, Va., naval restricted areas.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., Va., naval restricted areas. 334.290 Section 334.290 Navigation and Navigable Waters CORPS OF....290 Elizabeth River, Southern Branch, Va., naval restricted areas. (a) The areas—(1) St. Helena Annex Area. Beginning at a point at St. Helena Annex of the Norfolk Naval Shipyard, on the eastern shore of...
33 CFR 334.290 - Elizabeth River, Southern Branch, Va., naval restricted areas.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., Va., naval restricted areas. 334.290 Section 334.290 Navigation and Navigable Waters CORPS OF....290 Elizabeth River, Southern Branch, Va., naval restricted areas. (a) The areas—(1) St. Helena Annex Area. Beginning at a point at St. Helena Annex of the Norfolk Naval Shipyard, on the eastern shore of...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-24
... General Chapter'' (Q4B Annex 7). The revised guidance specifies additional dissolution apparatuses to... Canada consideration. This second revision, Q4B Annex 7(R2), specifies additional dissolution apparatuses to which interchangeability applies in the three ICH regions: The Basket Apparatus (Apparatus 1), the...
Conceptual study of the cryocascade for pumping, separation and recycling of ITER torus exhaust
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mack, A.; Perinic, D.
1994-12-31
For pumping, separation and recycling of the ITER plasma exhaust, a pumping system working reliably under ambient and operating conditions of the ITER reactor is required. The pump is exposed to a magnetic field of about 3 T and has to be resistant to radioactive irradiation of 10{sup 9} rad. In the burn and dwell phase, a gas mixture consisting of hydrogen isotopes, helium ash and impurities has to be pumped at the pressure range of 10{sup {minus}2} - 10{sup {minus}1} mbar. Within the framework of the European Fusion Technology Programme, the concept of a primary cryopump for use inmore » ITER is being prepared at KfK. The cryocascade concept is planned to include three pump stages. These pump stages, which are connected in series, consist of individual chambers that may be separated from each other by means of cold valves. In the first stage, the impurities of the reactor exhaust gas are frozen out at 20-30 K. Settling of the hydrogen isotopes H/D/T on the 5 K cryosurfaces takes place in the second stage. This stage is made up of two parallel chambers, which can be switched from the pumping to the regeneration mode or vice versa. The helium fraction is bound in the downstream 5 K adsorption stage.« less
Dobie, Robert A
2006-10-01
To discuss appropriate and inappropriate methods for comparing distributions of hearing thresholds of a study group with distributions in population standards and to determine whether the thresholds of Washington State Ferries engineers are different from those of men in the general population, using both frequency-by-frequency comparisons and analysis of audiometric shape. The most recent hearing conservation program audiograms of 321 noise-exposed engineers, ages 35 to 64, were compared with the predictions of Annexes A, B, and C from ANSI S3.44. There was no screening by history or otoscopy; all audiograms were included. 95% confidence intervals (95% CIs) were calculated for the engineers' median thresholds for each ear, for the better ear (defined two ways), and for the binaural average. For Annex B, where 95% CIs are also available, it was possible to calculate z scores for the differences between Annex B and the engineers' better ears. Bulge depth, an audiometric shape statistic, measured curvature between 1 and 6 kHz. Engineers' better-ear median thresholds were worse than those in Annex A but (except at 1 kHz) were as good as or better than those in Annexes B and C, which are more appropriate for comparison to an unscreened noise-exposed group like the engineers. Average bulge depth for the engineers was similar to that of the Annex B standard (no added occupational noise) and was much less than that of audiograms created by using the standard with added occupational noise between 90 and 100 dBA. Audiograms from groups that have been selected for a particular exposure, but, without regard to severity, can appropriately be compared with population standards, if certain pitfalls are avoided. For unscreened study groups with large age-sex subgroups, a simple method to assess statistical significance, taking into consideration uncertainties in both the study group and the comparison standard, is the calculation of z scores for the proportion of better-ear thresholds above the Annex B median. A less powerful method combines small age-sex subgroups after age correction. Small threshold differences, even if statistically significant, may not be due to genuine differences in hearing sensitivity between study group and standard. Audiometric shape analysis offers an independent dimension of comparison between the study group and audiograms predicted from the ANSI S3.44 standard, with and without occupational noise exposure. Important pitfalls in comparison to population standards include nonrandom selection of study groups, inappropriate choice of population standard, use of the right and left ear thresholds instead of the better-ear threshold for comparison to Annex B, and comparing means with medians. The thresholds of the engineers in this study were similar to published standards for an unscreened population.
Groundwater science relevant to the Great Lakes Water Quality Agreement: A status report
Grannemann, Norman G.; Van Stempvoort, Dale
2016-01-01
When the Great Lakes Water Quality Agreement (GLWQA) was signed in 1972 by the Governments of Canada and the United States (the “Parties”) (Environment Canada, 2013a), groundwater was not recognized as important to the water quality of the Lakes. At that time, groundwater and surface water were still considered as two separate systems, with almost no appreciation for their interaction. When the GLWQA was revised in 1978 (US Environmental Protection Agency (USEPA), 2012), groundwater contamination, such as that reported at legacy industrial sites such as those at Love Canal near the Niagara River, was squarely in the news. Consequently, the potential impacts of contaminated groundwater from such sites on Great Lakes water quality became a concern (Beck, 1979), and Annex 16 was added to the agreement, to address “pollution from contaminated groundwater” (Francis, 1989). However, no formal process for reporting under this annex was provided. The GLWQA Protocol in 1987 modified Annex 16 and called for progress reports beginning in 1988 (USEPA, 1988). The Protocol in 2012 provided a new Annex 8 to address groundwater more holistically (Environment 2 Canada, 2013b). Annex 8 (Environment Canada, 2013b) commits the Parties to coordinate groundwater science and management actions; as a first step, to “publish a report on the relevant and available groundwater science” by February 2015 (this report); and to “identify priorities for science activities and actions for groundwater management, protection, and remediation…” The broader mandate of Annex 8 is to (1) “identify groundwater impacts on the chemical, physical and biological integrity of the Waters of the Great Lakes;” (2) “analyze contaminants, including nutrients in groundwater, derived from both point and non-point sources impacting the Waters of the Great Lakes;” (3) “assess information gaps and science needs related to groundwater to protect the quality of the Waters of the Great Lakes;” and (4) “analyze other factors, such as climate change, that individually or cumulatively affect groundwater’s impact on the quality of the Waters of the Great Lakes.” A binational Annex 8 Subcommittee was formed to lead efforts to fulfill the mandate of this annex (members listed on p. i of this report). In turn, this subcommittee has recruited a task team to prepare this report (listed as authors of each chapter). This report addresses all of the above four objectives, based on a compilation of the “relevant and available groundwater science.” Specifically, the second objective (to “analyze contaminants”) is addressed by incorporating information obtained in ongoing monitoring and research activities conducted by the Parties, and by various other members of the Great Lakes Executive Committee.
78 FR 13481 - Implementation of MARPOL Annex V Amendments
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-28
... Management Facility. C. Privacy Act Anyone can search the electronic form of comments received into any of... ``impracticable, unnecessary, or contrary to the public interest.'' Under 5 U.S.C. 553(b)(B), the Coast Guard... and amendments made to Annex V as domestic law upon the amendments' entry into force ((33 U.S.C. 1901...
Teaching American Diplomacy Using Primary Sources. The Annexation of the Philippines.
ERIC Educational Resources Information Center
Zola, Jaye; Johnson, Jacquelyn S.
In this high school U.S. government and U.S. history curriculum unit, students examine in depth the annexation of the Philippines. Detailed activities are provided to teach students about U.S. foreign policy, the growth of the United States as a world power, and expansion and colonization in the Pacific Ocean. The materials include informational…
Global climate policy impacts on livestock, land use, livelihoods, and food security.
Golub, Alla A; Henderson, Benjamin B; Hertel, Thomas W; Gerber, Pierre J; Rose, Steven K; Sohngen, Brent
2013-12-24
Recent research has shed light on the cost-effective contribution that agriculture can make to global greenhouse gas abatement; however, the resulting impacts on agricultural production, producer livelihoods, and food security remain largely unexplored. This paper provides an integrated assessment of the linkages between land-based climate policies, development, and food security, with a particular emphasis on abatement opportunities and impacts in the livestock sector. Targeting Annex I countries and exempting non-Annex I countries from land-based carbon policies on equity or food security grounds may result in significant leakage rates for livestock production and agriculture as a whole. We find that such leakage can be eliminated by supplying forest carbon sequestration incentives to non-Annex I countries. Furthermore, substantial additional global agricultural abatement can be attained by extending a greenhouse gas emissions tax to non-Annex I agricultural producers, while compensating them for their additional tax expenses. Because of their relatively large emissions intensities and limited abatement possibilities, ruminant meat producers face the greatest market adjustments to land-based climate policies. We also evaluate the impacts of climate policies on livelihoods and food consumption in developing countries. In the absence of non-Annex I abatement policies, these impacts are modest. However, strong income and food consumption impacts surface because of higher food costs after forest carbon sequestration is promoted at a global scale. Food consumption among unskilled labor households falls but rises for the representative farm households, because global agricultural supplies are restricted and farm prices rise sharply in the face of inelastic food demands.
Global climate policy impacts on livestock, land use, livelihoods, and food security
Golub, Alla A.; Henderson, Benjamin B.; Hertel, Thomas W.; Gerber, Pierre J.; Rose, Steven K.; Sohngen, Brent
2013-01-01
Recent research has shed light on the cost-effective contribution that agriculture can make to global greenhouse gas abatement; however, the resulting impacts on agricultural production, producer livelihoods, and food security remain largely unexplored. This paper provides an integrated assessment of the linkages between land-based climate policies, development, and food security, with a particular emphasis on abatement opportunities and impacts in the livestock sector. Targeting Annex I countries and exempting non-Annex I countries from land-based carbon policies on equity or food security grounds may result in significant leakage rates for livestock production and agriculture as a whole. We find that such leakage can be eliminated by supplying forest carbon sequestration incentives to non-Annex I countries. Furthermore, substantial additional global agricultural abatement can be attained by extending a greenhouse gas emissions tax to non-Annex I agricultural producers, while compensating them for their additional tax expenses. Because of their relatively large emissions intensities and limited abatement possibilities, ruminant meat producers face the greatest market adjustments to land-based climate policies. We also evaluate the impacts of climate policies on livelihoods and food consumption in developing countries. In the absence of non-Annex I abatement policies, these impacts are modest. However, strong income and food consumption impacts surface because of higher food costs after forest carbon sequestration is promoted at a global scale. Food consumption among unskilled labor households falls but rises for the representative farm households, because global agricultural supplies are restricted and farm prices rise sharply in the face of inelastic food demands. PMID:23019587
The 1897 Petition against the Annexation of Hawaii. Teaching with Documents.
ERIC Educational Resources Information Center
National Archives and Records Administration, Washington, DC.
In 1893 the last monarch of Hawaii, Queen Lili'uokalani, was overthrown by a party of U.S. businessmen, who then imposed a provisional government. Soon after, U.S. President Benjamin Harrison submitted a treaty to annex the Hawaiian Islands to the U.S. Senate for ratification. In 1897, the treaty effort was blocked when the Hawaiian Patriotic…
2014-07-31
A-1 ANNEX B REFERENCES .................................................................................... B-1 ANNEX C GLOSSARY ... Occupational and environmental health surveillance consists of the assessment and accounting of physical, chemical, biological, and radiological...assessment is based on environmental health hazard and threat assessment, as well on environmental, occupational and disease surveillance information
International Collaboration on Offshore Wind Energy Under IEA Annex XXIII
DOE Office of Scientific and Technical Information (OSTI.GOV)
Musial, W.; Butterfield, S.; Lemming, J.
This paper defines the purpose of IEA Annex XXIII, the International Collaboration on Offshore Wind Energy. This international collaboration through the International Energy Agency (IEA) is an efficient forum from which to advance the technical and environmental experiences collected from existing offshore wind energy projects, as well as the research necessary to advance future technology for deep-water wind energy technology.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-19
... GENERAL SERVICES ADMINISTRATION [Wildlife Order 187; 4-D-FL-1218] Public Buildings Service; Key Largo Beacon Annex Site; Key Largo, FL; Transfer of Property Pursuant to section 2 of Public Law 537, 80th Congress, approved May 19, 1948 (16 U.S.C. 667c), notice is hereby given that: 1. The General...
School Consolidation Impact on State and Local Revenues and Expenditures in Texas
ERIC Educational Resources Information Center
Stewart, Marvin
2011-01-01
This study examined financial aspects of the consolidation or annexation of 12 pairs of school districts in Texas during the period 1996-2006. Nine of the twelve districts consolidated by mutual agreement of the two school boards and three annexations were by order of the Commissioner of Education of Texas. Financial criteria studied were: (a) per…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-25
... function as a naval ship. The intended effect of this rule is to warn mariners in waters where 72 COLREGS... as a naval ship: Annex I, paragraph 2(f)(i), pertaining to the placement of the masthead light or... the vertical placement of task lights; Annex I, paragraph 3(a), pertaining to the location of the...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-21
... special function as a naval ship. The intended effect of this rule is to warn mariners in waters where 72... provisions of 72 COLREGS without interfering with its special function as a naval ship: Annex I paragraph 2(a)(i), pertaining to the location of the height of the forward masthead light above the hull; Annex I...
Computerized microfluidic cell culture using elastomeric channels and Braille displays.
Gu, Wei; Zhu, Xiaoyue; Futai, Nobuyuki; Cho, Brenda S; Takayama, Shuichi
2004-11-09
Computer-controlled microfluidics would advance many types of cellular assays and microscale tissue engineering studies wherever spatiotemporal changes in fluidics need to be defined. However, this goal has been elusive because of the limited availability of integrated, programmable pumps and valves. This paper demonstrates how a refreshable Braille display, with its grid of 320 vertically moving pins, can power integrated pumps and valves through localized deformations of channel networks within elastic silicone rubber. The resulting computerized fluidic control is able to switch among: (i) rapid and efficient mixing between streams, (ii) multiple laminar flows with minimal mixing between streams, and (iii) segmented plug-flow of immiscible fluids within the same channel architecture. The same control method is used to precisely seed cells, compartmentalize them into distinct subpopulations through channel reconfiguration, and culture each cell subpopulation for up to 3 weeks under perfusion. These reliable microscale cell cultures showed gradients of cellular behavior from C2C12 myoblasts along channel lengths, as well as differences in cell density of undifferentiated myoblasts and differentiation patterns, both programmable through different flow rates of serum-containing media. This technology will allow future microscale tissue or cell studies to be more accessible, especially for high-throughput, complex, and long-term experiments. The microfluidic actuation method described is versatile and computer programmable, yet simple, well packaged, and portable enough for personal use.
Computerized microfluidic cell culture using elastomeric channels and Braille displays
Gu, Wei; Zhu, Xiaoyue; Futai, Nobuyuki; Cho, Brenda S.; Takayama, Shuichi
2004-01-01
Computer-controlled microfluidics would advance many types of cellular assays and microscale tissue engineering studies wherever spatiotemporal changes in fluidics need to be defined. However, this goal has been elusive because of the limited availability of integrated, programmable pumps and valves. This paper demonstrates how a refreshable Braille display, with its grid of 320 vertically moving pins, can power integrated pumps and valves through localized deformations of channel networks within elastic silicone rubber. The resulting computerized fluidic control is able to switch among: (i) rapid and efficient mixing between streams, (ii) multiple laminar flows with minimal mixing between streams, and (iii) segmented plug-flow of immiscible fluids within the same channel architecture. The same control method is used to precisely seed cells, compartmentalize them into distinct subpopulations through channel reconfiguration, and culture each cell subpopulation for up to 3 weeks under perfusion. These reliable microscale cell cultures showed gradients of cellular behavior from C2C12 myoblasts along channel lengths, as well as differences in cell density of undifferentiated myoblasts and differentiation patterns, both programmable through different flow rates of serum-containing media. This technology will allow future microscale tissue or cell studies to be more accessible, especially for high-throughput, complex, and long-term experiments. The microfluidic actuation method described is versatile and computer programmable, yet simple, well packaged, and portable enough for personal use. PMID:15514025
Hillman, L C; Chiragakis, L; Shadbolt, B; Kaye, G L; Clarke, A C
2008-02-15
It has been shown that the presence on diagnosis of endoscopic macroscopic markers indicates a high-risk group for Barrett's oesophagus. To determine whether proton pump inhibitor therapy prior to diagnosis of Barrett's oesophagus influences markers for risk development of subsequent high-grade dysplasia/adenocarcinoma. A review of all patients with Barrett's oesophagus entering a surveillance programme was undertaken. Five hundred and two patients diagnosed with Barrett's oesophagus were assessed on diagnosis for endoscopic macroscopic markers or low-grade dysplasia. Subsequent development of high-grade dysplasia/adenocarcinoma was documented. The relationship between the initiation of proton pump inhibitor therapy prior to the diagnosis of BE and the presence of macroscopic markers or low-grade dysplasia at entry was determined. Fourteen patients developed high-grade dysplasia/adenocarcinoma during surveillance. Patients who entered without prior proton pump inhibitor therapy were 3.4 times (95% CI: 1.98-5.85) more likely to have a macroscopic marker or low-grade dysplasia than those patients already on a proton pump inhibitor. Use of proton pump inhibitor therapy prior to diagnosis of Barrett's oesophagus significantly reduced the presence of markers used to stratify patient risk. Widespread use of proton pump inhibitors will confound surveillance strategies for patients with Barrett's oesophagus based on entry characteristics but is justified because of the lower risk of neoplastic progression.
NASA Astrophysics Data System (ADS)
Oeser, Martin; Dohmen, Ralf; Horn, Ingo; Schuth, Stephan; Weyer, Stefan
2018-05-01
The authors regret that equations EA.4 and EA.5 in the Electronic Annex were incomplete. Please see the new, corrected version of the Electronic Annex for the complete formulations of these equations. Accordingly, the correct formulation of Eq. (2) on page 132 is as follows:
Code of Federal Regulations, 2012 CFR
2012-01-01
... INTERNATIONAL CARRIAGE OF PERISHABLE FOODSTUFFS AND ON THE SPECIAL EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP... procedures in ATP, Annex 1, Appendix 2, paragraphs 31-40 and 43-47 shall be used. A report of each test shall be completed on a form corresponding to the pertinent test report model prescribed in ATP, Annex 1...
Code of Federal Regulations, 2014 CFR
2014-01-01
... INTERNATIONAL CARRIAGE OF PERISHABLE FOODSTUFFS AND ON THE SPECIAL EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP... procedures in ATP, Annex 1, Appendix 2, paragraphs 31-40 and 43-47 shall be used. A report of each test shall be completed on a form corresponding to the pertinent test report model prescribed in ATP, Annex 1...
Code of Federal Regulations, 2013 CFR
2013-01-01
... INTERNATIONAL CARRIAGE OF PERISHABLE FOODSTUFFS AND ON THE SPECIAL EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP... procedures in ATP, Annex 1, Appendix 2, paragraphs 31-40 and 43-47 shall be used. A report of each test shall be completed on a form corresponding to the pertinent test report model prescribed in ATP, Annex 1...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 3 2014-07-01 2014-07-01 false York River and the Naval Weapons... RESTRICTED AREA REGULATIONS § 334.285 York River and the Naval Weapons Station Yorktown-Cheatham Annex... less than the maximum range of the weapons being used at the facility or while a vessel is within the...
Thermal In-Pouch Microwave Sterilization
2012-01-09
technologies. Annex TOPIC Page Overview & Summary 2 1 Quantification of Hexanal in Yogurt and Extra Virgin Olive Oil as an indicator of Photo Oxidation 8...reports addressing the above-mentioned five goals and incorporates them as annexes here. 1. Methods 1. Quantification ofHexanal in Yogurt and... yogurt and extra virgin olive oil) from light- catalyzed degradation of linoleic acid to hexanal. Several alternative opacifying tactics were evaluated
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-30
... safety, Navigation (water), and Vessels. For the reasons set forth in the preamble, amend part 706 of... forward Vessel No. visibility; visibility; visibility; ship's sides stern in above hull in light in meters 2(k) Annex rule 21(a) rule 21(b) rule 21(c) in meters 3(b) meters; rule meters; 2(k) 1 Annex 1 21(c...
ERIC Educational Resources Information Center
Robinson, Barbara M.
This report contains annex materials from a study conducted for the New Jersey State Library (NJSL) with two major objectives: (1) to determine how much it costs two state contract libraries--the Central Library of the Newark Public Library and the Bureau of Law and Reference of the New Jersey State Library--to provide supplemental question…
Funding Site Cleanup at Closing Army Installations: A Stochastic Optimization Approach
2001-12-19
Devens Devens Massachusetts C 29 FORSCOM Hingham Annex Hingham Massachusetts C 30 FORSCOM Sudbury Training Annex Sudbury Massachusetts C 31 FORSCOM Fort ...RI 900 RD 200 RAC 1200 RAO...MINF efb COST y MAXF efa ∈ ∈ − ≤ ≤ +∑ ∑ ∀i,t (1) m i s mt mt ost os mt mt i FORT s SITE o OPTION
DOE Office of Scientific and Technical Information (OSTI.GOV)
de la Camara, S.N.
1958-10-01
The Spanish experimental swimming pool reactor is constructed on the grounds of the Ciudad Universitaria de Madrid. A general layout of the reactor building and its annexes is given, and the reactor building itself is described. The construction of the reactor building and the characteristics of the annex building are discussed. (J.S.R.)
Turbidity threshold sampling for suspended sediment load estimation
Jack Lewis; Rand Eads
2001-01-01
Abstract - The paper discusses an automated procedure for measuring turbidity and sampling suspended sediment. The basic equipment consists of a programmable data logger, an in situ turbidimeter, a pumping sampler, and a stage-measuring device. The data logger program employs turbidity to govern sample collection during each transport event. Mounting configurations and...
Implementation guide for turbidity threshold sampling: principles, procedures, and analysis
Jack Lewis; Rand Eads
2009-01-01
Turbidity Threshold Sampling uses real-time turbidity and river stage information to automatically collect water quality samples for estimating suspended sediment loads. The system uses a programmable data logger in conjunction with a stage measurement device, a turbidity sensor, and a pumping sampler. Specialized software enables the user to control the sampling...
Begolo, Stefano; Zhukov, Dmitriy V; Selck, David A; Li, Liang; Ismagilov, Rustem F
2014-12-21
Equipment-free pumping is a challenging problem and an active area of research in microfluidics, with applications for both laboratory and limited-resource settings. This paper describes the pumping lid method, a strategy to achieve equipment-free pumping by controlled generation of pressure. Pressure was generated using portable, lightweight, and disposable parts that can be integrated with existing microfluidic devices to simplify workflow and eliminate the need for pumping equipment. The development of this method was enabled by multi-material 3D printing, which allows fast prototyping, including composite parts that combine materials with different mechanical properties (e.g. both rigid and elastic materials in the same part). The first type of pumping lid we describe was used to produce predictable positive or negative pressures via controlled compression or expansion of gases. A model was developed to describe the pressures and flow rates generated with this approach and it was validated experimentally. Pressures were pre-programmed by the geometry of the parts and could be tuned further even while the experiment was in progress. Using multiple lids or a composite lid with different inlets enabled several solutions to be pumped independently in a single device. The second type of pumping lid, which relied on vapor-liquid equilibrium to generate pressure, was designed, modeled, and experimentally characterized. The pumping lid method was validated by controlling flow in different types of microfluidic applications, including the production of droplets, control of laminar flow profiles, and loading of SlipChip devices. We believe that applying the pumping lid methodology to existing microfluidic devices will enhance their use as portable diagnostic tools in limited resource settings as well as accelerate adoption of microfluidics in laboratories.
Climate change mitigation policies and poverty in developing countries
NASA Astrophysics Data System (ADS)
Hussein, Zekarias; Hertel, Thomas; Golub, Alla
2013-09-01
Mitigation of the potential impacts of climate change is one of the leading policy concerns of the 21st century. However, there continues to be heated debate about the nature, the content and, most importantly, the impact of the policy actions needed to limit greenhouse gas emissions. One contributing factor is the lack of systematic evidence on the impact of mitigation policy on the welfare of the poor in developing countries. In this letter we consider two alternative policy scenarios, one in which only the Annex I countries take action, and the second in which the first policy is accompanied by a forest carbon sequestration policy in the non-Annex regions. Using an economic climate policy analysis framework, we assess the poverty impacts of the above policy scenarios on seven socio-economic groups in 14 developing countries. We find that the Annex-I-only policy is poverty friendly, since it enhances the competitiveness of non-Annex countries—particularly in agricultural production. However, once forest carbon sequestration incentives in the non-Annex regions are added to the policy package, the overall effect is to raise poverty in the majority of our sample countries. The reason for this outcome is that the dominant impacts of this policy are to raise returns to land, reduce agricultural output and raise food prices. Since poor households rely primarily on their own labor for income, and generally own little land, and since they also spend a large share of their income on food, they are generally hurt on both the earning and the spending fronts. This result is troubling, since forest carbon sequestration—particularly through avoided deforestation—is a promising, low cost option for climate change mitigation.
Imperial Senate: American Legislative Debates on Empire, 1898-1917
2013-09-01
University Press of Kansas, 1980), 19; Edmund Morris , Theodore Rex (New York: Random House, 2001), 479–80. 118 31 Cong. Rec. 3976 (16 April 1898...mid-paragraph Senator Mason abruptly requested unanimous consent for a vote on McEnery’s resolution and amendments the following Tuesday afternoon...libweb.hawaii.edu/digicoll/annexation/annexation.html. Morris , Edmund. Theodore Rex. New York: Random House, 2001. Musicant, Ivan. Empire by
2011-05-01
Annex Case Study Bay Impairment Low Dissolved Oxygen Poor Water Clarity Too Much Bad Algae 3 Impaired Water Note: Representation of 303(d...Bioretention Regional pond Grass Channels Dry swale Level spreader Soils compost amendments Wet swale Underground detention Vegetated Roofs Filtering...practice Oil/grit separator Rainwater harvesting Constructed wetlands Tree box filter Permeable pavement Wet ponds Other: ________________ Existing
ERIC Educational Resources Information Center
European Commission, 2017
2017-01-01
This document, "Annex 1 to the Final Report to DG Education, Youth, Sport and Culture of the European Commission" is intended as a companion piece to European Commission report "Preparing Teachers for Diversity: The Role of Initial Teacher Education. Final Report". It contains country fiches which are overviews of available…
An Ecological Assessment of Johnston Atoll
2012-01-01
annexation of Johnston Atoll, which he called Kalama Atoll. The guano deposits were mined until the 1880s. The US Government annexed Hawaii in 1898... Government ) and others, who were from the Bishop Museum, Honolulu, HI with support from the Department of Agriculture and the US Navy. They arrived by boat... governed by an Environmental Protection Agency permit under the federal hazardous waste law, Resource Conservation and Recovery Act. JACADS completed
Phase 2 Site Investigations Report. Volume 3 of 3: Appendices
1994-09-01
Phase II Site Investigations Ee Report Cn Volume III of III Appendices Fort Devens Sudbury Training Annex, Massachusetts September 1994 Contract No...laboratory quality control (QC) samples collected during field investigations at the Sudbury Training Annex of Fort Devens , Massachusetts. The QC...returned to its original condition. E & E performed this procedure for each monitoring well tested during the 1993 slug testing activities at Fort Devens
Realization of a Complex Control & Diagnosis System on Simplified Hardware
NASA Astrophysics Data System (ADS)
Stetter, R.; Swamy Prasad, M.
2015-11-01
Energy is an important factor in today's industrial environment. Pump systems account for about 20% of the total industrial electrical energy consumption. Several studies show that with proper monitoring, control and maintenance, the efficiency of pump systems can be increased. Controlling pump systems with intelligent systems can help to reduce a pump's energy consumption by up to one third of its original consumption. The research in this paper was carried out in the scope of a research project which involves modelling and simulation of pump systems. This paper focuses on the future implementation of modelling capabilities in PLCs (programmable logic controllers). The whole project aims to use a pump itself as the sensor rather than introducing external sensors into the system, which would increase the cost considerably. One promising approach for an economic and robust industrial implementation of this intelligence is the use of PLCs. PLCs can be simulated in multiple ways; in this project, Codesys was chosen for several reasons which are explained in this paper. The first part of this paper explains the modelling of a pump itself, the process load of the asynchronous motor with a control system, and the simulation possibilities of the motor in Codesys. The second part describes the simulation and testing of a system realized. The third part elaborates the Codesys system structure and interfacing of the system with external files. The final part consists of comparing the result with an earlier Matlab/SIMULINK model and original test data.
1986-05-01
obtained and 317 forwarded to USAMRIID, with 272 having LNI’s of 0.3 or higher. Testing of febrile patients for evidence of Lassa virus (LV) infection ...at a rehabilitation center near GWH revealed evidence of previous LV infection in 22 of 288 leprosy patients, 4 of 52 family members of these patients...Virus Infections in the Families of Lassa Fever Patients Annex 3. Record of Household Epidemiology Study 49 Annex 4. Means of Obtaining Samples for IFA
ERIC Educational Resources Information Center
European Commission, 2017
2017-01-01
"Preparing Teachers for Diversity: The Role of Initial Teacher Education. Annex 2 To the Final Report to DG Education, Youth, Sport and Culture of the European Commission. Case Study Summaries" is designed as a companion document to the final report "Preparing Teachers for Diversity: The Role of Initial Teacher Education. Final…
Iraq: Oil and Gas Legislation, Revenue Sharing, and U.S. Policy
2008-04-02
international oil companies or the INOC , and Annex 4 delineated 65 exploration blocks. The KRG posted its analysis of the draft annexes on its website...establish an Iraqi National Oil Company ( INOC ). Under the hydrocarbon framework law, the responsibilities and authorities of the Ministry of Oil and the... INOC would be altered significantly, and the draft Ministry and INOC laws are necessary to ensure proper oversight, accountability, and separation of
Telemetry Standards, RCC Standard 106-17, Annex A.1, Pulse Amplitude Modulation Standards
2017-07-01
conform to either Figure Error! No text of specified style in document.-1 or Figure Error! No text of specified style in document.-2. Figure Error...No text of specified style in document.-1. 50 percent duty cycle PAM with amplitude synchronization A 20-25 percent deviation reserved for pulse...synchronization is recommended. Telemetry Standards, RCC Standard 106-17 Annex A.1, July 2017 A.1.2 Figure Error! No text of specified style
Base Structure Annex to Manpower Requirements Report for FY 1985.
1984-01-01
A 04 .I S DEPARTMENT OF DEFENSE BASE STRUCTURE ANNEX Toct 00 Manpower Requirements Report for FY 1985 JANUARY 1984 DTIC ELECTE FEB 2 7 4 >~fB OFFICE...JANUARY 1984 DTIC S ELECTE FEB27 1984 Prepared by Office of the Assistant Secretary of Defense (Manpower, Installations and Logistics) D&MM_ ffA-1ENo...individuals - Intelligence and Camunications 604 Individuals - Airlift/Sealift Forces 605 tndividua~ s - Guard and Reserves 609 Individ&ls - Training
1991-02-01
to adequately assess the health and environmental risks associated with the closure and transfer of the Annex forI other use; and 3) identification of...1990); Draft Final Technical Plan, Draft Final Sampling Design Plan and Draft Final Health and Safety Plan, USATHAMA, June 1990. 2.1.2 Draft Final...Final Technical Plan, Sampling Design Plan and Health and Safety Plan) supplied by USATHAMA. The estimate may be revised, with USATHAMA approval, as
Iraq: Oil and Gas Legislation, Revenue Sharing, and U.S. Policy
2007-10-02
INOC , and Annex 4 delineated 65 exploration blocks. The KRG posted its analysis of the draft annexes on its website, available at [http://www.krg.org...legislative package are proposed laws that will reorganize Iraq’s Ministry of Oil and establish an Iraqi National Oil Company ( INOC ). Under the hydrocarbon...framework law, the responsibilities and authorities of the Ministry of Oil and the INOC would be altered significantly, and the draft Ministry and INOC
Iraq: Oil and Gas Legislation, Revenue Sharing, and U.S. Policy
2009-07-17
Measuring Stability and Security in Iraq - June 2007, pp. 9, 11-12. 23 Some of the presumptive contracts for oil exploration in Iraq, signed with the...production,” Annex 3 listed 27 fields not near production and open to international oil companies or the INOC , and Annex 4 delineated 65 exploration...legislative package are proposed laws that will reorganize Iraq’s Ministry of Oil and establish an Iraqi National Oil Company ( INOC ). Under the hydrocarbon
A New Method for Global Optimization Based on Stochastic Differential Equations.
1984-12-01
Optimizacion Global de Funciones, Universidad Nacional Autonoma de M~xico, Instituto de Investigaciones en Matematicas Aplicadas y en Sistemas, Report...SIGMA package and its usage are described in full de - tail in Annex A5; the complete listing of the FORTRAN code is in Annex A6. 5. Test problems Since...software implemen- tation on a number of test problems: and therefore a collection of test problems naturally began to build up during project de - velopment
The Design and Implementation of Persistence in the Annex System
2009-08-01
MONADS [Rosenberg 1990], Grasshopper [Dearle, di Bona et al. 1993], the Walnut kernel [Castro 1996], the L3 microkernel [Liedtke 1993] and its...successor L4 [Skoglund, Ceelen & Liedtke 2000], KeyKOS [Hardy 1985] and Charm [Dearle & Hulse 2000]. There is a great difference in design between these...persistence are Annex and the L4 micro-kernel [Skoglund, Ceelen & Liedtke 2000]. In either case, to implement some form of persistence a system must have a
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ziritt, Jose Luis
The results from Annex XIII of the Cooperative Agreement between the United States Department of Energy (DOE) and the Ministry of Energy and Mines of the Republic of Venezuela (MEMV) have been documented and published with many researchers involved. Integrate comprehensive research programs in the area of Microbial Enhanced Oil Recovery (MEOR) ranged from feasibility laboratory studies to full-scale multi-well field pilots. The objective, to cooperate in a technical exchange of ideas and information was fully met throughout the life of the Annex. Information has been exchanged between the two countries through published reports and technical meetings between experts inmore » both country's research communities. The meetings occurred every two years in locations coincident with the International MEOR conferences & workshops sponsored by DOE (June 1990, University of Oklahoma, September 1992, Brookhaven, September 1995, National Institute of Petroleum and Energy Research). Reports and publications produced during these years are listed in Appendix B. Several Annex managers have guided the exchange through the years. They included Luis Vierma, Jose Luis Zirritt, representing MEMV and E. B. Nuckols, Edith Allison, and Rhonda Lindsey, representing the U.S. DOE. Funding for this area of research remained steady for a few years but decreased in recent years. Because both countries have reduced research programs in this area, future exchanges on this topic will occur through ANNEX XV. Informal networks established between researchers through the years should continue to function between individuals in the two countries.« less
NASA Astrophysics Data System (ADS)
Lin, H.; Jin, Y.; Giglio, L.; Foley, J. A.; Randerson, J. T.
2010-12-01
Fires in agricultural ecosystems emit greenhouse gases and aerosols that influence climate on multiple spatial and temporal scales. Annex 1 countries of the United Nations Framework Convention on Climate Change (UNFCCC), many of which ratified the Kyoto Protocol, are required to report emissions of CO2, CH4 and N2O from these fires annually. We evaluated several aspects of this reporting system, including the optimality of the crops targeted by the UNFCCC globally and within Annex 1 countries and the consistency of emissions reporting among countries. We also evaluated the success of the individual countries in capturing interannual variability and long-term trends in agricultural fire activity. We combined global crop maps with Terra and Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) active fire detections. At a global scale, we recommend adding ground nuts, cocoa, cotton and oil palm, and removing potato, oats, pulse other and rye from the UNFCCC list of 14 crops. This leads to an overall increase of 6% of the active fires covered by the reporting system. Optimization led to a different recommended list for Annex 1 countries. Extending emissions reporting to all Annex 1 countries (from the current set of 19 countries) would increase the efficacy of the reporting system from 10% to 20%, and further including several non-Annex 1 countries (Argentina, Brazil, China, India, Indonesia, Thailand, Kazakhstan, Mexico and Nigeria) would capture over 58% of active fires in croplands worldwide. Analyses of interannual trends from the U.S. and Australia showed the importance of both intensity of fire use and crop production in controlling year-to-year variations in agricultural fire emissions. Remote sensing provides an efficient tool for an independent assessment of current UNFCCC emissions reporting system; and, if combined with census data, field experiments and expert opinion, has the potential for improving the robustness of the next generation inventory system.
Ibáñez-Sanz, Gemma; Garcia, Montse; Rodríguez-Moranta, Francisco; Binefa, Gemma; Gómez-Matas, Javier; Domènech, Xènia; Vidal, Carmen; Soriano, Antonio; Moreno, Víctor
2016-10-01
The most common side effect in population screening programmes is a false-positive result which leads to unnecessary risks and costs. To identify factors associated with false-positive results in a colorectal cancer screening programme with the faecal immunochemical test (FIT). Cross-sectional study of 472 participants with a positive FIT who underwent colonoscopy for confirmation of diagnosis between 2013 and 2014. A false-positive result was defined as having a positive FIT (≥20μg haemoglobin per gram of faeces) and follow-up colonoscopy without intermediate/high-risk lesions or cancer. Women showed a two-fold increased likelihood of a false-positive result compared with men (adjusted OR, 2.3; 95%CI, 1.5-3.4), but no female-specific factor was identified. The other variables associated with a false-positive result were successive screening (adjusted OR, 1.5; 95%CI, 1.0-2.2), anal disorders (adjusted OR, 3.1; 95%CI, 2.1-4.5) and the use of proton pump inhibitors (adjusted OR, 1.8; 95%CI, 1.1-2.9). Successive screening and proton pump inhibitor use were associated with FP in men. None of the other drugs were related to a false-positive FIT. Concurrent use of proton pump inhibitors at the time of FIT might increase the likelihood of a false-positive result. Further investigation is needed to determine whether discontinuing them could decrease the false-positive rate. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
2002-05-01
the agreement through improved organization and definition of the agency’s mission, funding of state grants for pollution control in the Great Lakes...upon and committed to implement. Although most of the annexes specify pollution prevention strategies, Annex 2 calls for the preparation of RAPs to...management plans for the open waters of each lake to reduce loadings of critical pollutants in order to restore beneficial uses. 2 See U.S. General
ERIC Educational Resources Information Center
Commission of the European Communities, Brussels (Belgium).
This annex to the main report, the third volume in a three volume set, is based on a study performed by the DELTA (Developing European Learning through Technological Advance) unit in parallel with the projects underway in the research and development Exploratory Action. It provides an assessment of the world situation in flexible and distance…
The many transformations of the University of Illinois Observatory Annex
NASA Astrophysics Data System (ADS)
Svec, Michael
2018-04-01
The University of Illinois Observatory acquired a second-hand 30-inch Brashear reflector in 1912 with the intent of dedicating it to photoelectric photometry. A small observatory annex was built adjacent to the main observatory. This smaller observatory and its telescope underwent multiple transitions and instrument changes over the next 70 years, reflecting the research interests of Joel Stebbins and Robert H. Baker. The story of this observatory telescope illustrates changes in astronomical instrumentation and research over the course of the twentieth century.
Force XXI: Directions in Digitization - Symposium Report.
1996-08-21
J. KWINN, JR. LTC DAVID W. HUTCHISON COL JAMES L. KAYS 7 . PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) USMA OPERATIONS RESEARCH CENTER WEST...I would also like to acknowledge the many people who worked hard to put on this symposium: Colonel James L. Kays for providing the vision, faith...Appendix D-5: Organi2ation D-5-1 Appendix D-6: Interoperability D-6-1 Appendix D- 7 : Readiness D- 7 -1 Annex E: Transcripts from Symposium E-l Annex F
1945-02-01
8217COmIIAND OF MAJOR- GENERAL del VALLE: R. O, BARE, Col, USMC, ·C of S. ANNEXES: ABLE - Distribution B1iKER - Intelligence CHARLIE - Naval Gunfire Support Plan...3. ABLE Annex BAKER to Opn Plan 1-45, 1st MarDiv-(Rein) INTELLIGENCE 00015 1st Mar Div (Rein). 1990-5-80 In The Field 475/355 . 1100, 1OFeb, 1945. AP...distributed. (c) JANIS No. 86, August, 1944; JANIS No. 86 (Change 1), October 1944. (d) Engineer Intelligence Information of OKINAWA SHIMA prepared by Eng
1978-10-01
Information ; Logistics Planning; Management Planning and Control; Management Information Systems; Management; Military Supplies; Acquisition; JO...Arlington, Virginia 22202 Contract DAHC 15-73C-0200 Task 78-II-1 CONTENTS GLOSSARY : v SUMMARY ix I. INTRODUCTION 1 II. MARINE CORPS SUPPORT OP...Materiel Command Navy Cost Information System/FYDP Subsystem Non-Industrial Fund Non-Telecommunications Offfice of the Assistant Secretary of Defense
2015-07-01
annex. iii Self-defense testing was limited to structural test firing from each machine gun mount and an ammunition resupply drill. Robust self...provided in the classified annex. Self- 8 defense testing was limited to structural test firing from each machine gun mount and a single...Caliber Machine Gun Mount Structural Test Fire November 2014 San Diego, Offshore Ship Weapons Range Operating Independently 9 Section Three
The photovoltaic pilot projects of the European Community
NASA Astrophysics Data System (ADS)
Schnell, W.
The Commission of the European Communities has started in 1980 a programme for the design and construction of a series of photovoltaic pilot projects in the range of 30-300 kWp. Virtually all important industries and other development organisations in Europe working on photovoltaic cells and systems are involved in this programme. The different technologies which are being developed concern the modules, the cabling of the array, structure design, storage strategy and power conditioning. The various applications include powering of an island, villages, recreation centres, water desalination and disinfection, powering of radio transmitters, emergency power plants, dairy farm, training school, cooling, water pumping, powering of a solar heated swimming pool and last but not least, hydrogen production.
Yin, Yanchun; Chew, Andrew; Ren, Xiaoming; Li, Jie; Wang, Yang; Wu, Yi; Chang, Zenghu
2017-01-01
We present an approach for both efficient generation and amplification of 4–12 μm pulses by tailoring the phase matching of the nonlinear crystal Zinc Germanium Phosphide (ZGP) in a narrowband-pumped optical parametric chirped pulse amplifier (OPCPA) and a broadband-pumped dual-chirped optical parametric amplifier (DC-OPA), respectively. Preliminary experimental results are obtained for generating 1.8–4.2 μm super broadband spectra, which can be used to seed both the signal of the OPCPA and the pump of the DC-OPA. The theoretical pump-to-idler conversion efficiency reaches 27% in the DC-OPA pumped by a chirped broadband Cr2+:ZnSe/ZnS laser, enabling the generation of Terawatt-level 4–12 μm pulses with an available large-aperture ZGP. Furthermore, the 4–12 μm idler pulses can be compressed to sub-cycle pulses by compensating the tailored positive chirp of the idler pulses using the bulk compressor NaCl, and by indirectly controlling the higher-order idler phase through tuning the signal (2.4–4.0 μm) phase with a commercially available acousto-optic programmable dispersive filter (AOPDF). A similar approach is also described for generating high-energy 4–12 μm sub-cycle pulses via OPCPA pumped by a 2 μm Ho:YLF laser. PMID:28367966
Low-cost feedback-controlled syringe pressure pumps for microfluidics applications.
Lake, John R; Heyde, Keith C; Ruder, Warren C
2017-01-01
Microfluidics are widely used in research ranging from bioengineering and biomedical disciplines to chemistry and nanotechnology. As such, there are a large number of options for the devices used to drive and control flow through microfluidic channels. Commercially available syringe pumps are probably the most commonly used instruments for this purpose, but are relatively high-cost and have inherent limitations due to their flow profiles when they are run open-loop. Here, we present a low-cost ($110) syringe pressure pump that uses feedback control to regulate the pressure into microfluidic chips. Using an open-source microcontroller board (Arduino), we demonstrate an easily operated and programmable syringe pump that can be run using either a PID or bang-bang control method. Through feedback control of the pressure at the inlets of two microfluidic geometries, we have shown stability of our device to within ±1% of the set point using a PID control method and within ±5% of the set point using a bang-bang control method with response times of less than 1 second. This device offers a low-cost option to drive and control well-regulated pressure-driven flow through microfluidic chips.
Low-cost feedback-controlled syringe pressure pumps for microfluidics applications
Lake, John R.; Heyde, Keith C.
2017-01-01
Microfluidics are widely used in research ranging from bioengineering and biomedical disciplines to chemistry and nanotechnology. As such, there are a large number of options for the devices used to drive and control flow through microfluidic channels. Commercially available syringe pumps are probably the most commonly used instruments for this purpose, but are relatively high-cost and have inherent limitations due to their flow profiles when they are run open-loop. Here, we present a low-cost ($110) syringe pressure pump that uses feedback control to regulate the pressure into microfluidic chips. Using an open-source microcontroller board (Arduino), we demonstrate an easily operated and programmable syringe pump that can be run using either a PID or bang-bang control method. Through feedback control of the pressure at the inlets of two microfluidic geometries, we have shown stability of our device to within ±1% of the set point using a PID control method and within ±5% of the set point using a bang-bang control method with response times of less than 1 second. This device offers a low-cost option to drive and control well-regulated pressure-driven flow through microfluidic chips. PMID:28369134
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1979-04-01
The principal features of the existing environment of Egypt are characterized and the main problem areas identified in Annex 11. The environmental, health, and associated social issues that must be considered in choosing from among the options available to Egypt for meeting projected future energy needs are identified. The environmental impacts associated with these options are discussed and observations are made of alternte ways to minimize environmental insults. Annex 12, Manpower, analyzes the energy-related manpower situation of Egypt. Manpower education and training resources of Egypt; the existing manpower base of Egypt; manpower needs of the energy strategies; a comparison ofmore » manpower needs and existing manpower base; and the underlying economic and social factors that will make Egypt energy facility development very difficult to plan and execute are discussed. Annex 13 summarizes a preliminary analysis of the capital, labor, materials, and equipment resources required to implement alternative Egyptian energy futures and documents the assessment of several Egyptian energy development programs selected by the DOE. It egins with brief overviews of the ESPM model and data base. It then describes the method by which the system was adapted to Egyptian conditions and the results of this modification. The comparison Case energy development program is described, followed by a summary of ESPM-derived facility and resource requirements. Finally, the sensitivity of these results to several alternative energy strategies is illustrated.« less
Latest update of tests and improvements to US Coast Guard viscous oil pumping system.
Drieu, Michael D; Nourse, Peter C; MacKay, Ronald; Cooper, David A; Hvidbak, Flemming
2003-01-01
Over the past nine years, the US Coast Guard has incorporated the prevention through people (PTP) philosophy as a "human factors" approach to learn how maritime operations can be regulated safer and be more efficient by evaluating training, management policies, operational procedures, and establishing partnerships with the maritime industry. One of the key elements of applying a PTP approach is identifying and incorporating lessons learned from major marine casualties and pollution incidents. Since 1997, the US Coast Guard National Strike Force has responded to three major oil spills involving foreign freight vessels grounding, which included the removal of highly viscous oil using various lightering equipment and systems. An informal workgroup consisting of the US Coast Guard, US Navy Supervisor of Salvage (NAVSUPSALV), and various representatives from oil pollution clean-up companies met at the following facilities: the Chevron Asphalt Facility in Edmonds, WA (September 1999), the Oil and Hazardous Materials Simulated Environmental Test Tank (OHMSETT) testing facility in Leonardo, New Jersey (November 1999 and March 2000), the Alaska Clean Seas (ACS) warehouse annex in Prudhoe Bay, AK (October 2000), and Cenac Towing Company facility in Houma, LA (May 2002). The group shared ideas and techniques, and tested different pumps and hose lengths with viscous oil. It was during the early tests that the first quantitative results showed just how efficient lubricated transport of heavy oil product could be, and broadened the knowledge of such methods to the entire industry. Although this technology had existed for many years in the oil production and handling industry, its use had never been investigated in a laboratory setting with regard to salvage response lightering systems.
Law No. 76 of 1988, Third Amendment to the Law of Juveniles Welfare, No. 76 of 1983, 20 June 1988.
1988-01-01
This Act amends the Iraq Juveniles Welfare Act to attach to the Juveniles Rehabilitation House an annex for young "vagrant" or "perverted" females and to provide that, if a lodged female reaches the age of 18 and has lost her family or fears for her life if she is returned to her family, she may, upon order of the Juveniles Court, be sheltered in the annex until she is 22, marries, finds suitable work, or voluntarily is returned to her family. full text
2015-01-01
SEXUAL ASSAULT AND SEXUAL HARASSMENT IN THE U.S. MILITARY Annex to Volume 3. Tabular Results from the 2014 RAND Military Workplace Study for... Sexual Harassment in the U.S. Military: Top-Line Estimates for Active-Duty Service Members from the 2014 RAND Military Workplace Study • Sexual ...Assault and Sexual Harassment in the U.S. Military: Top-Line Estimates for Active-Duty Coast Guard Members from the 2014 RAND Military Workplace Study vi
1978-10-01
Force , Navy and Marine Corps. Coverage is less comprehensive on the Army because of work on this topic by the General Research Corporation. Volume I...presents recommendations on an OSD-level LRA data system. Volumes II, III, and IV cQver the Navy, Air Force , and Marine Corps respectively. Each of these...Resource Model/ Force Level Analysis Interactive Language System NAVAIR Naval Air Systems Command NAVCOMPT Navy Comptroller NAVFAC Naval Facilities
Urban Combat Advanced Training Technology (Technologie avancee d’entrainement au combat urbain)
2015-07-01
Environmental Issues 2-1 2.6 Annex E – Effects Representation on Targets 2-2 2.7 Annex F – How to Create Vulnerability Models for Buildings and Vehicles 2-2...Modifications of the Standard Information Models 3-10 3.3.5 Why the RPR FOM 2 Might Not be Suitable for All Types of Integration 3-10 3.4 Implementation ...urban areas are the most likely battlefield in the 21st century. The problems and limitations associated with developing the first generation of
Rupture loop annex ion exchange RLAIX vault deactivation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ham, J.E.; Harris, D.L., Westinghouse Hanford
This engineering report documents the deactivation, stabilization and final conditions of the Rupture Loop Annex Ion Exchange (RLAIX) Vault located northwest of the 309 Building`s Plutonium Recycle Test Reactor (PRTR). Twelve ion exchange columns, piping debris, and column liquid were removed from the vault, packaged and shipped for disposal. The vault walls and floor were decontaminated, and portions of the vault were painted to fix loose contamination. Process piping and drains were plugged, and the cover blocks and rain cover were installed. Upon closure,the vault was empty, stabilized, isolated.
A programmable palm-size gas analyzer for use in micro-autonomous systems
NASA Astrophysics Data System (ADS)
Gordenker, Robert J. M.; Wise, Kensall D.
2012-06-01
Gas analysis systems having small size, low power, and high selectivity are badly needed for defense (detection of explosives and chemical warfare agents), homeland security, health care, and environmental applications. This paper presents a palm-size gas chromatography system having analysis times of 5-50sec, detection limits less than 1ppb, and an average power dissipation less than one watt. It uses no consumables. The three-chip fluidic system consists of a preconcentrator, a 25cm-3m separation column, and a chemi-resistive detector and is supported by a microcomputer and circuitry for programmable temperature control. The entire system, including the mini-pump and battery, occupies less than 200cc and is configured for use on autonomous robotic vehicles.
Lin, Hsiao-Wen; Jin, Yufang; Giglio, Louis; Foley, Jonathan A; Randerson, James T
2012-06-01
Fires in agricultural ecosystems emit greenhouse gases and aerosols that influence climate on multiple spatial and temporal scales. Annex 1 countries of the United Nations Framework Convention on Climate Change (UNFCCC), many of which ratified the Kyoto Protocol, are required to report emissions of CH4 and N2O from these fires annually. In this study, we evaluated several aspects of this reporting system, including the optimality of the crops targeted by the UNFCCC globally and within Annex 1 countries, and the consistency of emissions inventories among different countries. We also evaluated the success of individual countries in capturing interannual variability and long-term trends in agricultural fire activity. In our approach, we combined global high-resolution maps of crop harvest area and production, derived from satellite maps and ground-based census data, with Terra and Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) measurements of active fires. At a global scale, we found that adding ground nuts (e.g., peanuts), cocoa, cotton and oil palm, and removing potato, oats, rye, and pulse other from the list of 14 crops targeted by the UNFCCC increased the percentage of active fires covered by the reporting system by 9%. Optimization led to a different recommended list for Annex 1 countries, requiring the addition of sunflower, cotton, rapeseed, and alfalfa and the removal of beans, sugarcane, pulse others, and tuber-root others. Extending emissions reporting to all Annex 1 countries (from the current set of 19 countries) would increase the efficacy of the reporting system from 6% to 15%, and further including several non-Annex 1 countries (Argentina, Brazil, China, India, Indonesia, Thailand, Kazakhstan, Mexico, and Nigeria) would capture over 55% of active fires in croplands worldwide. Analyses of interannual trends from the United States and Australia showed the importance of both intensity of fire use and crop production in controlling year-to-year variations in agricultural fire emissions. Remote sensing provides an effective means for evaluating some aspects of the current UNFCCC emissions reporting system; and, if combined with census data, field experiments and expert opinion, has the potential to improve the robustness of the next generation inventory system.
[Culture-bound syndromes: pertinence as a diagnostic category].
Perez, S; Junod, A; Pilard, M
2000-01-01
Culture-bound syndromes (CBS) are supposedly confined to one specific cultural areas. These syndromes were first studied by western anthropologists and psychiatrists working overseas, and later by practitioners treating patients from societies with traditional customs and values. The latest edition of the American Psychiatry Association classification (DSM IV) includes an annex on CBS. This report gives a concise background of the process that led to the inclusion of this annex. Then using Koro (a sudden and intense fear that the genitals organs will recede into the body) as an example, a number psychopathological parallels are drawn between CBS and classic manifestations of individual and mass hysteria. The pertinence of individualizing the CBS in the psychiatric nosography including the epistemologic implications is analyzed with reference to the concepts of the French and American Schools of Anthropology. Since attitudes toward mental illness are culturally determined and subject to variation in time and space, we feel that this debate should be placed within the context of a general dialectic between etic (universality) and emic (cultural specificity) rather than a controversy on the need for an annex on CBS in the DSM IV.
Exploring the clean development mechanism: Malaysian case study.
Pedersen, Anne
2008-02-01
During 2006 the CDM market in Malaysia became established and by December 2007 a total of 20 Malaysian projects had registered with the CDM Executive Board. The Kyoto Protocol defines the Annex 1 countries, as countries that are obliged to reduce their greenhouse gas (GHG) emissions and the clean development mechanism (CDM) allows Annex 1 countries to develop projects, which contribute to emission reduction, in non-Annex 1 (developing) countries. Currently, two projects have been corrected due to request for review and there is one project for which review is requested. Two projects have been rejected by the Executive Board. The broad knowledge of CDM in Malaysia and the number of successful projects are partly due to the well-functioning CDM institutional framework in Malaysia. As an illustration this article focuses on a Malaysian-Danish project and describes the implementation of CDM in Malaysia and refers to this specific project. The project was registered with the CDM Executive Board in May 2007 and is a methane avoidance project in which methane is captured from a landfill and used to generate electricity.
Pratt, Nicole L; Kalisch Ellett, Lisa M; Sluggett, Janet K; Gadzhanova, Svetla V; Ramsay, Emmae N; Kerr, Mhairi; LeBlanc, Vanessa T; Barratt, John D; Roughead, Elizabeth E
2017-02-01
To evaluate the impact of national multifaceted initiatives to improve use of proton pump inhibitors (PPIs) on the use of PPIs among older Australians. Interrupted time series analysis using administrative health claims data from the Australian Government Department of Veterans' Affairs (DVA). Australia. All veterans and dependents who received PPIs between January 2003 and December 2013. National, multifaceted interventions to improve PPI use were conducted by the Australian Government Department of Veterans' Affairs Veterans' MATES programme and Australia's NPS MedicineWise in April 2004, June 2006, May 2009 and August 2012. Trends in monthly rate of use of any PPI among the veteran population, and the monthly rate of use of low strength PPIs among all veterans dispensed a PPI. Interventions in 2004, 2006, 2009 and 2012 slowed the rate of increase in PPI use significantly, with the 2012 intervention resulting in a sustained 0.04% decrease in PPI use each month. The combined effect of all four interventions was a 20.9% (95% CI 7.8-33.9%) relative decrease in PPI use 12 months after the final intervention. The four interventions also resulted in a 42.2% (95% CI 19.9-64.5%) relative increase in low strength PPI use 12 months after the final intervention. National multifaceted programmes targeting clinicians and consumers were effective in reducing overall PPI use and increasing use of low strength PPIs. Interventions to improve PPI use should incorporate regular repetition of key messages to sustain practice change. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Programmable controlled mode-locked fiber laser using a digital micromirror device.
Liu, Wu; Fan, Jintao; Xie, Chen; Song, Youjian; Gu, Chenlin; Chai, Lu; Wang, Chingyue; Hu, Minglie
2017-05-15
A digital micromirror device (DMD)-based arbitrary spectrum amplitude shaper is incorporated into a large-mode-area photonic crystal fiber laser cavity. The shaper acts as an in-cavity programmable filter and provides large tunable dispersion from normal to anomalous. As a result, mode-locking is achieved in different dispersion regimes with watt-level high output power. By programming different filter profiles on the DMD, the laser generates femtosecond pulse with a tunable central wavelength and controllable bandwidth. Under conditions of suitable cavity dispersion and pump power, design-shaped spectra are directly obtained by varying the amplitude transfer function of the filter. The results show the versatility of the DMD-based in-cavity filter for flexible control of the pulse dynamics in a mode-locked fiber laser.
Densmore, Jill N.; Cox, Brett F.; Crawford, Steven M.
1997-01-01
Because ground water is the only dependable source of water in the Barstow area, a thorough understanding of the relationship between the geology and hydrology of this area is needed to make informed ground-water management andremediation decisions. This report summarizes geologic and hydrologic studies done during 1992-95 at the Marine Corps Logistics Base, Nebo and Yermo Annexes, near Barstow, California. The geologic investigation dealt with the stratigraphy and geologic history of the area and determined the location of faults that cross the Marine Corps Logistics Base, Nebo Annex. Two of these faultscoincide with significant ground-water barriers. Geologic and hydrologic data collected for this study were used to define two main aquifer systems in this area. The Mojave River aquifer is contained within the sand and gravel of the Mojave River alluvium, and the regional aquifer lies in the bordering alluvial-fan deposits and older alluvium. Water-level data showed that recharge occurs exten sively in the Mojave River aquifer but occurs only in small areas of the regional aquifer. Dissolved- solids concentrations showed that ground-water degradation exists in the Mojave River aquifer near the Nebo Annex and extends at least 1 mile downgradient of the Nebo golf course in the younger Mojave River alluvium. Nitrogen concentrations show that more than one source is causing the observed degradation in the Mojave River aquifer. Oxygen-18, deuterium, tritium, andcarbon-14 data indicate that the Mojave River and regional aquifers have different sources of recharge and that recent recharge occurs in the Mojave River aquifer but is more limited in the regional aquifer.
Chao, Morgan G; Dubé, Anne-Julie; Leone, Cortney M; Moore, Christina M; Fraser, Angela M
2016-11-01
Human noroviruses are the leading cause of foodborne disease in the United States, sickening 19 to 21 million Americans each year. Vomit and diarrhea are both highly concentrated sources of norovirus particles. For this reason, establishing appropriate cleanup procedures for these two substances is critical. Food service establishments in states that have adopted the 2009 or 2013 U.S. Food and Drug Administration Food Code are required to have a program detailing specific cleanup procedures. The aim of our study was to determine the alignment of existing vomit and diarrhea cleanup procedures with the 11 elements recommended in Annex 3 of the 2011 Supplement to the 2009 Food Code and to determine their readability and clarity of presentation. In July 2015, we located vomit and diarrhea cleanup procedures by asking Norovirus Collaborative for Outreach, Research, and Education stakeholders for procedures used by their constituency groups and by conducting a Google Advanced Search of the World Wide Web. We performed content analysis to determine alignment with the recommendations in Annex 3. Readability and clarity of presentation were also assessed. A total of 38 artifacts were analyzed. The mean alignment score was 7.0 ± 1.7 of 11 points; the mean clarity score was 6.7 ± 2.5 of 17 points. Only nine artifacts were classified as high clarity, high alignment. Vomit and diarrhea cleanup procedures should align with Annex 3 in the Food Code and should, as well, be clearly presented; yet, none of the artifacts completely met both conditions. To reduce the spread of norovirus infections in food service establishments, editable guidelines are needed that are aligned with Annex 3 and are clearly written, into which authors could insert their facility-specific information.
Global comparison of VOC and CO observations in urban areas
NASA Astrophysics Data System (ADS)
von Schneidemesser, Erika; Monks, Paul S.; Plass-Duelmer, Christian
2010-12-01
Speciated volatile organic compound (VOC) and carbon monoxide (CO) measurements from the Marylebone Road site in central London from 1998 through 2008 are presented. Long-term trends show statistically significant decreases for all the VOCs considered, ranging from -3% to -26% per year. Carbon monoxide decreased by -12% per year over the measurement period. The VOC trends observed at the kerbside site in London showed greater rates of decline relative to trends from monitoring sites in rural England (Harwell) and a remote high-altitude site (Hohenpeissenberg), which showed decreases for individual VOCs from -2% to -13% per year. Over the same 1998 through 2008 period VOC to CO ratios for London remained steady, an indication that emissions reduction measures affected the measured compounds equally. Relative trends comparing VOC to CO ratios between Marylebone Road and Hohenpeissenberg showed greater similarities than absolute trends, indicating that emissions reductions measures in urban areas are reflected by regional background locations. A comparison of VOC mixing ratios and VOC to CO ratios was undertaken for London and other global cities. Carbon monoxide and VOCs (alkanes greater than C 5, alkenes, and aromatics) were found to be strongly correlated (>0.8) in the Annex I countries, whereas only ethene and ethyne were strongly correlated with CO in the non-Annex I countries. The correlation results indicate significant emissions from traffic-related sources in Annex I countries, and a much larger influence of other sources, such as industry and LPG-related sources in non-Annex I countries. Yearly benzene to ethyne ratios for London from 2000 to 2008 ranged from 0.17 to 0.29 and compared well with previous results from US cities and three global megacities.
Wilson, Jesse W.; Park, Jong Kang; Warren, Warren S.
2015-01-01
The lock-in amplifier is a critical component in many different types of experiments, because of its ability to reduce spurious or environmental noise components by restricting detection to a single frequency and phase. One example application is pump-probe microscopy, a multiphoton technique that leverages excited-state dynamics for imaging contrast. With this application in mind, we present here the design and implementation of a high-speed lock-in amplifier on the field-programmable gate array (FPGA) coprocessor of a data acquisition board. The most important advantage is the inherent ability to filter signals based on more complex modulation patterns. As an example, we use the flexibility of the FPGA approach to enable a novel pump-probe detection scheme based on spread-spectrum communications techniques. PMID:25832238
Wilson, Jesse W; Park, Jong Kang; Warren, Warren S; Fischer, Martin C
2015-03-01
The lock-in amplifier is a critical component in many different types of experiments, because of its ability to reduce spurious or environmental noise components by restricting detection to a single frequency and phase. One example application is pump-probe microscopy, a multiphoton technique that leverages excited-state dynamics for imaging contrast. With this application in mind, we present here the design and implementation of a high-speed lock-in amplifier on the field-programmable gate array (FPGA) coprocessor of a data acquisition board. The most important advantage is the inherent ability to filter signals based on more complex modulation patterns. As an example, we use the flexibility of the FPGA approach to enable a novel pump-probe detection scheme based on spread-spectrum communications techniques.
116. Photographic copy of drawing (25 June 1917, original drawing ...
116. Photographic copy of drawing (25 June 1917, original drawing in Archives, Office of the Building, Administration Building, Sears, Roebuck and Company Mail Order Plant, Chicago, Illinois). Drawn by Sears Department 131. 1/64 inch to one foot. Schematic plan of the Merchandise Building, describing the type of construction of the different portions of the building and shows the layout of the railroad tracks around the building. At the date of this drawing the building had all the major additons complete (to Annex A, Annex B, and the Box Factory). SCHETMATIC FLOOR PLAN - Sears Roebuck & Company Mail Order Plant, Merchandise Building, 924 South Homan Avenue, Chicago, Cook County, IL
IEA EBC annex 53: Total energy use in buildings—Analysis and evaluation methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoshino, Hiroshi; Hong, Tianzhen; Nord, Natasa
One of the most significant barriers to achieving deep building energy efficiency is a lack of knowledge about the factors determining energy use. In fact, there is often a significant discrepancy between designed and real energy use in buildings, which is poorly understood but are believed to have more to do with the role of human behavior than building design. Building energy use is mainly influenced by six factors: climate, building envelope, building services and energy systems, building operation and maintenance, occupants’ activities and behavior, and indoor environmental quality. In the past, much research focused on the first three factors.more » However, the next three human-related factors can have an influence as significant as the first three. Annex 53 employed an interdisciplinary approach, integrating building science, architectural engineering, computer modeling and simulation, and social and behavioral science to develop and apply methods to analyze and evaluate the real energy use in buildings considering the six influencing factors. Finally, outcomes from Annex 53 improved understanding and strengthen knowledge regarding the robust prediction of total energy use in buildings, enabling reliable quantitative assessment of energy-savings measures, policies, and techniques.« less
IEA EBC annex 53: Total energy use in buildings—Analysis and evaluation methods
Yoshino, Hiroshi; Hong, Tianzhen; Nord, Natasa
2017-07-18
One of the most significant barriers to achieving deep building energy efficiency is a lack of knowledge about the factors determining energy use. In fact, there is often a significant discrepancy between designed and real energy use in buildings, which is poorly understood but are believed to have more to do with the role of human behavior than building design. Building energy use is mainly influenced by six factors: climate, building envelope, building services and energy systems, building operation and maintenance, occupants’ activities and behavior, and indoor environmental quality. In the past, much research focused on the first three factors.more » However, the next three human-related factors can have an influence as significant as the first three. Annex 53 employed an interdisciplinary approach, integrating building science, architectural engineering, computer modeling and simulation, and social and behavioral science to develop and apply methods to analyze and evaluate the real energy use in buildings considering the six influencing factors. Finally, outcomes from Annex 53 improved understanding and strengthen knowledge regarding the robust prediction of total energy use in buildings, enabling reliable quantitative assessment of energy-savings measures, policies, and techniques.« less
Tracing long-term vadose zone processes at the Nevada Test Site, USA
Hunt, James R.; Tompson, Andrew F. B.
2010-01-01
The nuclear weapons testing programme of the USA has released radionuclides to the subsurface at the Nevada Test Site. One of these tests has been used to study the hydrological transport of radionuclides for over 25 years in groundwater and the deep unsaturated zone. Ten years after the weapon’s test, a 16 year groundwater pumping experiment was initiated to study the mobility of radionuclides from that test in an alluvial aquifer. The continuously pumped groundwater was released into an unlined ditch where some of the water infiltrated into the 200 m deep vadose zone. The pumped groundwater had well-characterized tritium activities that were utilized to trace water migration in the shallow and deep vadose zones. Within the near-surface vadose zone, tritium levels in the soil water are modelled by a simple one-dimensional, analytical wetting front model. In the case of the near-surface soils at the Cambric Ditch experimental site, water flow and salt accumulation appear to be dominated by rooted vegetation, a mechanism not included within the wetting front model. Simulation results from a two-dimensional vadose groundwater flow model illustrate the dominance of vertical flow in the vadose zone and the recharge of the aquifer with the pumped groundwater. The long-time series of hydrological data provides opportunities to understand contaminant transport processes better in the vadose zone with an appropriate level of modelling. PMID:21785525
Risk factors for baclofen pump infection in children: a multivariate analysis.
Spader, Heather S; Bollo, Robert J; Bowers, Christian A; Riva-Cambrin, Jay
2016-06-01
OBJECTIVE Intrathecal baclofen infusion systems to manage severe spasticity and dystonia are associated with higher infection rates in children than in adults. Factors unique to this population, such as poor nutrition and physical limitations for pump placement, have been hypothesized as the reasons for this disparity. The authors assessed potential risk factors for infection in a multivariate analysis. METHODS Patients who underwent implantation of a programmable pump and intrathecal catheter for baclofen infusion at a single center between January 1, 2000, and March 1, 2012, were identified in this retrospective cohort study. The primary end point was infection. Potential risk factors investigated included preoperative (i.e., demographics, body mass index [BMI], gastrostomy tube, tracheostomy, previous spinal fusion), intraoperative (i.e., surgeon, antibiotics, pump size, catheter location), and postoperative (i.e., wound dehiscence, CSF leak, and number of revisions) factors. Univariate analysis was performed, and a multivariate logistic regression model was created to identify independent risk factors for infection. RESULTS A total of 254 patients were evaluated. The overall infection rate was 9.8%. Univariate analysis identified young age, shorter height, lower weight, dehiscence, CSF leak, and number of revisions within 6 months of pump placement as significantly associated with infection. Multivariate analysis identified young age, dehiscence, and number of revisions as independent risk factors for infection. CONCLUSIONS Young age, wound dehiscence, and number of revisions were independent risk factors for infection in this pediatric cohort. A low BMI and the presence of either a gastrostomy or tracheostomy were not associated with infection and may not be contraindications for this procedure.
NASA Astrophysics Data System (ADS)
Howlader, Harun Or Rashid; Matayoshi, Hidehito; Noorzad, Ahmad Samim; Muarapaz, Cirio Celestino; Senjyu, Tomonobu
2018-05-01
This paper presents a smart house-based power system for thermal unit commitment programme. The proposed power system consists of smart houses, renewable energy plants and conventional thermal units. The transmission constraints are considered for the proposed system. The generated power of the large capacity renewable energy plant leads to the violated transmission constraints in the thermal unit commitment programme, therefore, the transmission constraint should be considered. This paper focuses on the optimal operation of the thermal units incorporated with controllable loads such as Electrical Vehicle and Heat Pump water heater of the smart houses. The proposed method is compared with the power flow in thermal units operation without controllable loads and the optimal operation without the transmission constraints. Simulation results show the validation of the proposed method.
Ottria, G; Dallera, M; Aresu, O; Manniello, M A; Parodi, B; Spagnolo, A M; Cristina, M L
2010-12-01
Recent discoveries in cell therapy research present new opportunities for cellular products to be used to treat severe, and as yet incurable, diseases. It is therefore essential to implement a quality control programme in order to ensure that safe cells and tissues are provided. In a preliminary phase of the setting up of a the cellfactory, monitoring was carried out monthly over a 6-month period in one out of three cell therapy laboratories and filter rooms in order to evaluate the microbial contamination of air and surfaces and the presence of airborne particulates. The mean total bacterial and fungal loads measured in the air in the centre of the filter room were 20.7 +/1 28.9 colony-forming units (cfu)/m3 and 9.2 +/- 15.4 cfu/m3, respectively, and 5.2 +/- 4.1 cfu/m3 and 6.8 +/- 13.4 cfu/m3, respectively, in the laboratory. The mean fungal load values recorded on the surfaces sampled in the laboratory were in 6 out of 18 cases higher than the reference values (5 cfu/plate). As to the results of particulate monitoring, with regard to the 0.5 microm particles, about 83% of the samples revealed values below the limit of 350.000 particles per cubic metre. In this set-up phase, monitoring was able to pick out structural and organisational flaws acceptable in a laboratory compliant with Good Manufacturing Practices class C (Annex 1), but not in a class B facility. Thanks to this preliminary monitoring phase, and by correcting these flaws, the clean room facility could achieve compliance to class B.
Effects of pumping strategies on pesticide concentration of a drinking water well
NASA Astrophysics Data System (ADS)
Aisopou, A.; Bjerg, P. L.; Binning, P. J.; Albrechtsen, H.
2011-12-01
Groundwater is an important source of drinking water production in many countries including Denmark. This requires high quality groundwater that meets the standards of the European Water Framework Directive. Yet as a result of agricultural activitity, deposition and previous handling, pesticides are frequently found in groundwater and can raise a substantial problem for ground water abstraction. The concentration of this contamination may vary between different layers. The heterogeneity of the subsurface geology and the depth of the drinking water well's screen are important parameters that affect the resulting contamination of the abstracted groundwater. The pesticide concentration in wells may also be affected by the pumping strategy because pumping can alter the structure of the flow field, the flowpath of water going to the well and subsequently the age of water at the well. The purpose of this study was to examine numerically the effects of pumping on pesticide contamination of drinking water wells using a reactive transport model in a hypothetical aquifer system resembling a typical Danish well field. The application history of the pesticides is crucial. This can be taken into account by assessing the effects of pumping on water age distribution along the well. Three compounds with different application histories were considered: an old banned pesticide MCPP (Mecoprop) which is mobile and relatively persistent in deeper aquifers, and a highly applied, biodegradable and strongly sorbing pesticide glyphosate, and its degradation product AMPA. A steady state flow field was first computed. A well field was then introduced and different pumping regimes were applied for a period of 180 years; a low-rate pumping, a high-rate pumping and a varying pumping regime. A constant application rate at the surface was assumed for the application period of each pesticide. The pre-abstraction age distribution of the water in the system was first estimated using a steady-state flow and transport simulation. These water ages were then used as the initial conditions for the transient simulations. The results of the simulations showed that the range of water ages contributing to the well increased during pumping and was substantially affected by the pumping rate. High pesticide concentrations were persistent in the well 40 to 100 years after they were banned, due to the high residence times in the aquifer. Large changes in simulated pesticides concentrations at the well occurred during pumping. The pesticide concentration reaching the well was affected by the pumping regime and the pesticide application history and properties. A higher pumping rate induced a higher pesticide concentration peak at the well of shorter duration, while a lower pumping rate induced a lower concentration peak of longer duration. The long term scenarios revealed that at high pumping rates MCPP would disappear 40 years after its application end year, while glyphosate concentrations increase and reach a plateau, which is highly dependent on the pumping rate. The findings of the study help understand the results of groundwater monitoring programmes and can be used for the quantitative evaluation of management and pumping strategies for the long-term supply of safe potable groundwater.
Solid state control system for oil well bailer pump
DOE Office of Scientific and Technical Information (OSTI.GOV)
Senghaas, K. A.; Senghaas, P.
1985-05-14
A solid state switching controller for use with various types of oil well bailer pumps. Individually programmable steps with lockouts provide multiple mutual exclusivity between various circuit operations. A trickle charge battery system powers the control circuits. A tank overflow float protects against oil spillage. An automatic production rate adjustment circuit is provided which increases cycle time in proportion to the rate of production. The circuit includes a low power voltage detector for disabling the control circuits until the line voltage is acceptable. A three-phase power and control system with an isolation transformer for the controls avoids unreliable ground connections.more » The timers include a dividing circuit with an RC circuit. All power actuated apparatus are actuated by triac switches which are controlled by an opto driver. The bailer brake is pulse actuated for allowing the bailer to sink into crude oil without excess cable looseness.« less
2002-04-01
de mines à la mar jettisoned mine L lancement launch largage jettison largage de détresse en condition de sécurité safe...configuration logistique Etat des conditions d’un matériel prévu pour le stockage et le transport par voies de communication. Pour les munition...durée de vie en service, durée de vie opérationnelle, cycle de vie, conditions de stockage et de transit] ANNEX C to /ANNEXE C à
Heat pump system with selective space cooling
Pendergrass, J.C.
1997-05-13
A reversible heat pump provides multiple heating and cooling modes and includes a compressor, an evaporator and heat exchanger all interconnected and charged with refrigerant fluid. The heat exchanger includes tanks connected in series to the water supply and a condenser feed line with heat transfer sections connected in counterflow relationship. The heat pump has an accumulator and suction line for the refrigerant fluid upstream of the compressor. Sub-cool transfer tubes associated with the accumulator/suction line reclaim a portion of the heat from the heat exchanger. A reversing valve switches between heating/cooling modes. A first bypass is operative to direct the refrigerant fluid around the sub-cool transfer tubes in the space cooling only mode and during which an expansion valve is utilized upstream of the evaporator/indoor coil. A second bypass is provided around the expansion valve. A programmable microprocessor activates the first bypass in the cooling only mode and deactivates the second bypass, and vice-versa in the multiple heating modes for said heat exchanger. In the heating modes, the evaporator may include an auxiliary outdoor coil for direct supplemental heat dissipation into ambient air. In the multiple heating modes, the condensed refrigerant fluid is regulated by a flow control valve. 4 figs.
Heat pump system with selective space cooling
Pendergrass, Joseph C.
1997-01-01
A reversible heat pump provides multiple heating and cooling modes and includes a compressor, an evaporator and heat exchanger all interconnected and charged with refrigerant fluid. The heat exchanger includes tanks connected in series to the water supply and a condenser feed line with heat transfer sections connected in counterflow relationship. The heat pump has an accumulator and suction line for the refrigerant fluid upstream of the compressor. Sub-cool transfer tubes associated with the accumulator/suction line reclaim a portion of the heat from the heat exchanger. A reversing valve switches between heating/cooling modes. A first bypass is operative to direct the refrigerant fluid around the sub-cool transfer tubes in the space cooling only mode and during which an expansion valve is utilized upstream of the evaporator/indoor coil. A second bypass is provided around the expansion valve. A programmable microprocessor activates the first bypass in the cooling only mode and deactivates the second bypass, and vice-versa in the multiple heating modes for said heat exchanger. In the heating modes, the evaporator may include an auxiliary outdoor coil for direct supplemental heat dissipation into ambient air. In the multiple heating modes, the condensed refrigerant fluid is regulated by a flow control valve.
[Pharmacy students proceeding from Alsace and Moselle to Nancy between 1872 and 1914].
Labrude, Pierre; Remmel, François-Xavier
2004-01-01
Because of the war against Prussia, the school of pharmacy of Strasbourg was transfered to Nancy in 1872 with some of its professor. These professors are generally well known, but it is not the same for students who came from annexed departments to Nancy for studying pharmacy between 1872 and 1914. The archives stored in Nancy show that, during these fourty years, the quarter of pharmacy students in Nancy were native of Alsace or Moselle. We specify their number for each year after annexation. Some situations, illustrated by examples, are possible: young men who came in France before annexation, students who came with their family when they were children, pharmacists with a diploma obtained in Strasbourg having the wish to emigrate in France some years later. Our results lead to questions whose answers are difficult to formulate and would perhaps justify another study: what were the reasons for the obtaining of the french pharmacist diploma ?, what was the professional activity of these pharmacists ?, what was their posture during the First World War, did some of them return to Alsace or Moselle after the war? Whatever the answers, the presence of these < Alsaciens-Lorrains > students was significant and precious for the school of pharmacy of Nancy at this period.
The Earth Observation Data for Habitat Monitoring (EODHaM) system
NASA Astrophysics Data System (ADS)
Lucas, Richard; Blonda, Palma; Bunting, Peter; Jones, Gwawr; Inglada, Jordi; Arias, Marcela; Kosmidou, Vasiliki; Petrou, Zisis I.; Manakos, Ioannis; Adamo, Maria; Charnock, Rebecca; Tarantino, Cristina; Mücher, Caspar A.; Jongman, Rob H. G.; Kramer, Henk; Arvor, Damien; Honrado, Joāo Pradinho; Mairota, Paola
2015-05-01
To support decisions relating to the use and conservation of protected areas and surrounds, the EU-funded BIOdiversity multi-SOurce monitoring System: from Space TO Species (BIO_SOS) project has developed the Earth Observation Data for HAbitat Monitoring (EODHaM) system for consistent mapping and monitoring of biodiversity. The EODHaM approach has adopted the Food and Agriculture Organization Land Cover Classification System (LCCS) taxonomy and translates mapped classes to General Habitat Categories (GHCs) from which Annex I habitats (EU Habitats Directive) can be defined. The EODHaM system uses a combination of pixel and object-based procedures. The 1st and 2nd stages use earth observation (EO) data alone with expert knowledge to generate classes according to the LCCS taxonomy (Levels 1 to 3 and beyond). The 3rd stage translates the final LCCS classes into GHCs from which Annex I habitat type maps are derived. An additional module quantifies changes in the LCCS classes and their components, indices derived from earth observation, object sizes and dimensions and the translated habitat maps (i.e., GHCs or Annex I). Examples are provided of the application of EODHaM system elements to protected sites and their surrounds in Italy, Wales (UK), the Netherlands, Greece, Portugal and India.
Man-machine interface and control of the shuttle digital flight system
NASA Technical Reports Server (NTRS)
Burghduff, R. D.; Lewis, J. L., Jr.
1985-01-01
The space shuttle main engine (SSME) presented new requirements in the design of controls for large pump fed liquid rocket engine systems. These requirements were the need for built in full mission support capability, and complexity and flexibility of function not previously needed in this type of application. An engine mounted programmable digital control system was developed to meet these requirements. The engine system and controller and their function are described. Design challenges encountered during the course of development included accommodation for a very severe engine environment, the implementation of redundancy and redundancy management to provide fail operational/fail safe capability, removal of heat from the package, and significant constraints on computer memory size and processing time. The flexibility offered by programmable control reshaped the approach to engine design and development and set the pattern for future controls development in these types of applications.
UK service level audit of insulin pump therapy in paediatrics.
Ghatak, A; Paul, P; Hawcutt, D B; White, H D; Furlong, N J; Saunders, S; Morrison, G; Langridge, P; Weston, P J
2015-12-01
To conduct an audit of insulin pump therapy in the UK after the issue of guidelines for the use of continuous subcutaneous insulin infusion by NICE in 2008 (Technology Appraisal 151). All centres in the UK, providing pump services to children and young people were invited to participate in an online audit. Audit metrics were aligned to NICE Technology Appraisal 151 and an electronic data collection tool was used. Of the 176 UK centres identified as providing pump services, 166 (94.3%) participated in the study. A total of 5094 children and young people were identified as using continuous subcutaneous insulin infusion (19% of all paediatric patients with Type 1 diabetes), with a median (range) of 16.9 (0.67-69.4)% per centre. Units had a median of 0.58 consultant sessions, 0.43 full-time equivalent diabetic specialist nurses, and 0.1 full-time equivalent dieticians delivering the pump service. The majority of this time was not formally funded. Families could access 24-h clinical and technical support (83% units), although the delivery varied between consultant, diabetic specialist nurse and company representatives. Only 53% of units ran, or accessed, structured education programmes for continuous subcutaneous insulin infusion use. Most units (86%) allowed continuous subcutaneous insulin infusion use for paediatric inpatients, but only 56% had written guidelines for this scenario. Nine percent of units had encountered funding refusal for a patient fulfilling NICE (Technology Appraisal 151) criteria. The number of children and young people on continuous subcutaneous insulin infusion therapy is consistent with numbers estimated by NICE. There is a worrying lack of funded healthcare professional time. The audit also identified gaps in the provision of structured education and absence of written inpatient guidelines. © 2015 The Authors. Diabetic Medicine © 2015 Diabetes UK.
Code of Federal Regulations, 2012 CFR
2012-01-01
... SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Procedures for Separate Testing of Mechanical Refrigerating Appliances § 3300.34 General. ATP, Annex 1, Appendix 2...
Code of Federal Regulations, 2010 CFR
2010-01-01
... SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Procedures for Separate Testing of Mechanical Refrigerating Appliances § 3300.34 General. ATP, Annex 1, Appendix 2...
Code of Federal Regulations, 2014 CFR
2014-01-01
... SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Procedures for Separate Testing of Mechanical Refrigerating Appliances § 3300.34 General. ATP, Annex 1, Appendix 2...
Code of Federal Regulations, 2011 CFR
2011-01-01
... SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Procedures for Separate Testing of Mechanical Refrigerating Appliances § 3300.34 General. ATP, Annex 1, Appendix 2...
Code of Federal Regulations, 2013 CFR
2013-01-01
... SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Procedures for Separate Testing of Mechanical Refrigerating Appliances § 3300.34 General. ATP, Annex 1, Appendix 2...
Guo, Liang; Monahan, Daniele M; Fleming, Graham
2016-08-08
Spectrometers and cameras are used in ultrafast spectroscopy to achieve high resolution in both time and frequency domains. Frequency-resolved signals from the camera pixels cannot be processed by common lock-in amplifiers, which have only a limited number of input channels. Here we demonstrate a rapid and economical method that achieves the function of a lock-in amplifier using mechanical choppers and a programmable microcontroller. We demonstrate the method's effectiveness by performing a frequency-resolved pump-probe measurement on the dye Nile Blue in solution.
Inappropriate enrollment of children in schools for the visually impaired in east Africa.
Tumwesigye, C; Msukwa, G; Njuguna, M; Shilio, B; Courtright, P; Lewallen, S
2009-06-01
Many visually impaired children can learn to read print with appropriate training and simple visual aids. This may allow them to attend normal schools and to be integrated into society, which has lifelong benefits. Yet, in Africa, many visually impaired children are enrolled in special schools and taught only Braille. The purpose of this analysis was to document the extent of inappropriate enrollment of visually impaired children in special schools and annexes for the blind in four African countries. Schools were selected through a population-proportional-to-size method so that they would represent all children attending special schools in Kenya, Malawi, Tanzania and Uganda. Children were examined by ophthalmologists trained in standardised methods to determine visual acuity and the cause of decreased acuity. Of 1062 children examined in special schools and annexes for the blind, 361 (34%, 95% CI 31.2, 36.8) had visual acuity >or=6/60; the most common cause of visual impairment was retinal disease. Of the 120 children with normal vision (>or=6/18), 69 (57.5%) had two normal eyes, 21 (17.5%) had an obvious ocular disfigurement in the fellow eye and 10 (8.4%) had had successful cataract surgery. In these countries, many children are placed inappropriately in special schools and annexes for the blind. The reasons are multiple and to rectify the situation will require advocacy and cooperation between ministries of health and education.
Bolch, W E; Dietze, G; Petoussi-Henss, N; Zankl, M
2015-06-01
Based upon recent epidemiological studies of ocular exposure, the Main Commission of the International Commission on Radiological Protection (ICRP) in ICRP Publication 118 states that the threshold dose for radiation-induced cataracts is now considered to be approximately 0.5 Gy for both acute and fractionated exposures. Consequently, a reduction was also recommended for the occupational annual equivalent dose to the lens of the eye from 150 mSv to 20 mSv, averaged over defined periods of 5 years. To support ocular dose assessment and optimisation, Committee 2 included Annex F within ICRP Publication 116 . Annex F provides dose coefficients - absorbed dose per particle fluence - for photon, electron, and neutron irradiation of the eye and lens of the eye using two dosimetric models. The first approach uses the reference adult male and female voxel phantoms of ICRP Publication 110. The second approach uses the stylised eye model of Behrens et al., which itself is based on ocular dimensional data given in Charles and Brown. This article will review the data and models of Annex F with particular emphasis on how these models treat tissue regions thought to be associated with stem cells at risk. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
A new method for automated dynamic calibration of tipping-bucket rain gauges
Humphrey, M.D.; Istok, J.D.; Lee, J.Y.; Hevesi, J.A.; Flint, A.L.
1997-01-01
Existing methods for dynamic calibration of tipping-bucket rain gauges (TBRs) can be time consuming and labor intensive. A new automated dynamic calibration system has been developed to calibrate TBRs with minimal effort. The system consists of a programmable pump, datalogger, digital balance, and computer. Calibration is performed in two steps: 1) pump calibration and 2) rain gauge calibration. Pump calibration ensures precise control of water flow rates delivered to the rain gauge funnel; rain gauge calibration ensures precise conversion of bucket tip times to actual rainfall rates. Calibration of the pump and one rain gauge for 10 selected pump rates typically requires about 8 h. Data files generated during rain gauge calibration are used to compute rainfall intensities and amounts from a record of bucket tip times collected in the field. The system was tested using 5 types of commercial TBRs (15.2-, 20.3-, and 30.5-cm diameters; 0.1-, 0.2-, and 1.0-mm resolutions) and using 14 TBRs of a single type (20.3-cm diameter; 0.1-mm resolution). Ten pump rates ranging from 3 to 154 mL min-1 were used to calibrate the TBRs and represented rainfall rates between 6 and 254 mm h-1 depending on the rain gauge diameter. All pump calibration results were very linear with R2 values greater than 0.99. All rain gauges exhibited large nonlinear underestimation errors (between 5% and 29%) that decreased with increasing rain gauge resolution and increased with increasing rainfall rate, especially for rates greater than 50 mm h-1. Calibration curves of bucket tip time against the reciprocal of the true pump rate for all rain gauges also were linear with R2 values of 0.99. Calibration data for the 14 rain gauges of the same type were very similar, as indicated by slope values that were within 14% of each other and ranged from about 367 to 417 s mm h-1. The developed system can calibrate TBRs efficiently, accurately, and virtually unattended and could be modified for use with other rain gauge designs. The system is now in routine use to calibrate TBRs in a large rainfall collection network at Yucca Mountain, Nevada.
19 CFR 115.51 - Technical requirements.
Code of Federal Regulations, 2012 CFR
2012-04-01
... TREASURY CARGO CONTAINER AND ROAD VEHICLE CERTIFICATION PURSUANT TO INTERNATIONAL CUSTOMS CONVENTIONS... submitted for inspection for individual approval must comply with the requirements of Annex 2 of the Customs...
19 CFR 115.51 - Technical requirements.
Code of Federal Regulations, 2011 CFR
2011-04-01
... TREASURY CARGO CONTAINER AND ROAD VEHICLE CERTIFICATION PURSUANT TO INTERNATIONAL CUSTOMS CONVENTIONS... submitted for inspection for individual approval must comply with the requirements of Annex 2 of the Customs...
19 CFR 115.51 - Technical requirements.
Code of Federal Regulations, 2010 CFR
2010-04-01
... TREASURY CARGO CONTAINER AND ROAD VEHICLE CERTIFICATION PURSUANT TO INTERNATIONAL CUSTOMS CONVENTIONS... submitted for inspection for individual approval must comply with the requirements of Annex 2 of the Customs...
19 CFR 115.51 - Technical requirements.
Code of Federal Regulations, 2014 CFR
2014-04-01
... TREASURY CARGO CONTAINER AND ROAD VEHICLE CERTIFICATION PURSUANT TO INTERNATIONAL CUSTOMS CONVENTIONS... submitted for inspection for individual approval must comply with the requirements of Annex 2 of the Customs...
19 CFR 115.51 - Technical requirements.
Code of Federal Regulations, 2013 CFR
2013-04-01
... TREASURY CARGO CONTAINER AND ROAD VEHICLE CERTIFICATION PURSUANT TO INTERNATIONAL CUSTOMS CONVENTIONS... submitted for inspection for individual approval must comply with the requirements of Annex 2 of the Customs...
Hacking medical devices a review - biomed 2013.
Frenger, Paul
2013-01-01
Programmable, implantable and external biomedical devices (such as pacemakers, defibrillators, insulin pumps, pain management pumps, vagus nerve stimulators and others) may be vulnerable to unauthorized access, commonly referred to as hacking. This intrusion may lead to compromise of confidential patient data or loss of control of the device itself, which may be deadly. Risks to health from unauthorized access is in addition to hazards from faulty (buggy) software or circuitry. Historically, this aspect of medical device design has been underemphasized by both manufacturers and regulatory bodies until recently. However, an insulin pump was employed as a murder weapon in 2001 and successful hacking of an implantable defibrillator was demonstrated in 2008. To remedy these problems, professional groups have announced a variety of design standards and the governmental agencies of several countries have enacted device regulations. In turn, manufacturers have developed new software products and hardware circuits to assist biomedical engineering firms to improve their commercial offerings. In this paper the author discusses these issues, reviewing known problems and zero-day threats, with potential solutions. He outlines his approach to secure software and hardware challenges using the Forth language. A plausible scenario is described in which hacking of an implantable defibrillator by terrorists results in a severe national security threat to the United States.
A multicenter study on the audiometric findings of styrene-exposed workers.
Morata, Thais C; Sliwinska-Kowalska, Mariola; Johnson, Ann-Christin; Starck, Jukka; Pawlas, Krystyna; Zamyslowska-Szmytke, Ewa; Nylen, Per; Toppila, Esko; Krieg, Edward; Pawlas, Natalia; Prasher, Deepak
2011-10-01
The objective of this study was to evaluate hearing loss among workers exposed to styrene, alone or with noise. This cross-sectional study was conducted as part of NoiseChem, a European Commission 5th Framework Programme research project, by occupational health institutes in Finland, Sweden, and Poland. Participants' ages ranged from 18-72 years (n = 1620 workers). Participants exposed to styrene, alone or with noise, were from reinforced fiberglass products manufacturing plants (n = 862). Comparison groups were comprised of workers noise-exposed (n = 400) or controls (n = 358). Current styrene exposures ranged from 0 to 309 mg/m(3), while mean current noise levels ranged from 70-84 dB(A). Hearing thresholds of styrene-exposed participants were compared with Annexes A and B from ANSI S3.44, 1996. The audiometric thresholds of styrene exposed workers were significantly poorer than those in published standards. Age, gender, and styrene exposure met the significance level criterion in the multiple logistic regression for the binary outcome 'hearing loss' (P = 0.0000). Exposure to noise (<85 dBA p = 0.0001; ≥85 dB(A) p = 0.0192) interacted significantly with styrene exposure. Occupational exposure to styrene is a risk factor for hearing loss, and styrene-exposed workers should be included in hearing loss prevention programs.
14 CFR 171.207 - Performance requirements.
Code of Federal Regulations, 2012 CFR
2012-01-01
....” (Annex 10 to the Convention on International Civil Aviation) except those portions that pertain to... electronic engineering practices for the desired service. The facility must be checked periodically during...
14 CFR 171.207 - Performance requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
....” (Annex 10 to the Convention on International Civil Aviation) except those portions that pertain to... electronic engineering practices for the desired service. The facility must be checked periodically during...
Arduino control of a pulsatile flow rig.
Drost, S; de Kruif, B J; Newport, D
2018-01-01
This note describes the design and testing of a programmable pulsatile flow pump using an Arduino micro-controller. The goal of this work is to build a compact and affordable system that can relatively easily be programmed to generate physiological waveforms. The system described here was designed to be used in an in-vitro set-up for vascular access hemodynamics research, and hence incorporates a gear pump that delivers a mean flow of 900 ml/min in a test flow loop, and a peak flow of 1106 ml/min. After a number of simple identification experiments to assess the dynamic behaviour of the system, a feed-forward control routine was implemented. The resulting system was shown to be able to produce the targeted representative waveform with less than 3.6% error. Finally, we outline how to further increase the accuracy of the system, and how to adapt it to specific user needs. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Fischell, Robert E. (Inventor)
1986-01-01
A medication infusion system provides redundant safety and includes condition detecting and informational alarm signal generating apparatus for indicating if (1) a fluid leak occurs in different portions of the system; (2) a programmable input from a patient or physician would result in exceeding a safe dosage limit; (3) the reservoir containing medication has been filled; (4) the intended medication pumping does not correlate with the pumping actually effected; (5) battery voltage is low; (6) the medication reserve is low; and (7) the system has been switched off. The apparatus may provide subcutaneous electrical, thermal, or audible stimulation to the patient and also provides a signal which a physician may monitor. The stimulation may be coded to separately identify each above-listed deviation in nominal system performance. In addition, the number of medication requests are correlated with actual medication dispensing to assure proper operation. An identification scheme is provided which matches the patient with his or her corresponding medication.
32 CFR 631.6 - Responsibilities.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., and economy of resources. (3) Assist Federal, State, and local law enforcement agencies within the... establishments per Annex A of appendix A of this part. (7) Distributing pertinent information to the following...
CFD simulation of a dry scroll vacuum pump with clearances, solid heating and thermal deformation
NASA Astrophysics Data System (ADS)
Spille-Kohoff, A.; Hesse, J.; Andres, R.; Hetze, F.
2017-08-01
Although dry scroll vacuum pumps (DSPV) are essential devices in many different industrial processes, the CFD simulation of such pumps is not widely used and often restricted to simplified cases due to its complexity: The working principle with a fixed and an orbiting scroll leads to working chambers that are changing in time and are connected through moving small radial and axial clearances in the range of 10 to 100 μm. Due to the low densities and low mass flow rates in vacuum pumps, it is important to include heat transfer towards and inside the solid components. Solid heating is very slow compared to the scroll revolution speed and the gas behaviour, thus a special workflow is necessary to reach the working conditions in reasonable simulation times. The resulting solid temperature is then used to compute the thermal deformation, which usually results in gap size changes that influence leakage flows. In this paper, setup steps and results for the simulation of a DSVP are shown and compared to theoretical and experimental results. The time-varying working chambers are meshed with TwinMesh, a hexahedral meshing programme for positive displacement machines. The CFD simulation with ANSYS CFX accounts for gas flow with compressibility and turbulence effects, conjugate heat transfer between gas and solids, and leakage flows through the clearances. Time-resolved results for torques, chamber pressure, mass flow, and heat flow between gas and solids are shown, as well as time- and space-resolved results for pressure, velocity, and temperature for different operating conditions of the DSVP.
NASA Astrophysics Data System (ADS)
Johnson, M. V. V.; Behrman, K. D.; Atwood, J. D.; White, M. J.; Norfleet, M. L.
2017-12-01
There is substantial interest in understanding how conservation practices and agricultural management impact water quality, particularly phosphorus dynamics, in the Western Lake Erie Basin (WLEB). In 2016, the US and Canada accepted total phosphorus (TP) load targets recommended by the Great Lakes Water Quality Agreement Annex 4 Objectives and Targets Task Team; these were 6,000 MTA delivered to Lake Erie and 3,660 MTA delivered to WLEB. Outstanding challenges include development of metrics to determine achievement of these goals, establishment of sufficient monitoring capacity to assess progress, and identification of appropriate conservation practices to achieve the most cost-effective results. Process-based modeling can help inform decisions to address these challenges more quickly than can system observation. As part of the NRCS-led Conservation Effects Assessment Project (CEAP), the Soil Water Assessment Tool (SWAT) was used to predict impacts of conservation practice adoption reported by farmers on TP loss and load delivery dynamics in WLEB. SWAT results suggest that once the conservation practices in place in 2003-06 and 2012 are fully functional, TP loads delivered to WLEB will average 3,175 MTA and 3,084 MTA, respectively. In other words, SWAT predicts that currently adopted practices are sufficient to meet Annex 4 TP load targets. Yet, WLEB gauging stations show Annex 4 goals are unmet. There are several reasons the model predictions and current monitoring efforts are not in agreement: 1. SWAT assumes full functionality of simulated conservation practices; 2. SWAT does not simulate changing management over time, nor impacts of past management on legacy loads; 3. SWAT assumes WLEB hydrological system equilibrium under simulated management. The SWAT model runs used to construct the scenarios that informed the Annex 4 targets were similarly constrained by model assumptions. It takes time for a system to achieve equilibrium when management changes and it takes time for monitoring efforts to measure meaningful changes over time. Careful interpretation of model outputs is imperative for appropriate application of current scientific knowledge to inform decision making, especially when models are used to set spatial and temporal goals around conservation practice adoption and water quality.
9. INTERIOR, XRAY ROOM, FROM DOORWAY, LOOKING SOUTHEAST. Oakland ...
9. INTERIOR, X-RAY ROOM, FROM DOORWAY, LOOKING SOUTHEAST. - Oakland Naval Supply Center, Administration Building-Dental Annex-Dispensary, Between E & F Streets, East of Third Street, Oakland, Alameda County, CA
42 CFR 37.42 - Approval of roentgenographic facilities.
Code of Federal Regulations, 2012 CFR
2012-10-01
... signal-to-noise and detective quantum efficiency must be evaluated and judged acceptable by a qualified...): (A) DICOM Standard PS 3.3-2011, Annex A—Composite Information Object Definitions, sections: Computed...
1963-11-16
CAPE CANAVERAL Fla. -- Maj. Gen. L. I. Davis, commander of the U.S. Air Force Missile Test Center, welcomes President John F. Kennedy to the Cape Canaveral Missile Test Annex in Florida. Photo Credit: NASA
42 CFR 37.42 - Chest radiograph specifications-digital radiography systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... signal-to-noise and detective quantum efficiency must be evaluated and judged acceptable by a qualified...): (A) DICOM Standard PS 3.3-2011, Annex A—Composite Information Object Definitions, sections: Computed...
47 CFR 80.1129 - Locating and homing signals.
Code of Federal Regulations, 2010 CFR
2010-10-01
... rescue radar transponders to assist the searching units. (b) Homing singnals are those locating signals... Recommendation M.628-3, “Technical Characteristics for Search and Rescue Radar Transponders,” with Annexes, 1994...
47 CFR 80.1129 - Locating and homing signals.
Code of Federal Regulations, 2011 CFR
2011-10-01
... rescue radar transponders to assist the searching units. (b) Homing singnals are those locating signals... Recommendation M.628-3, “Technical Characteristics for Search and Rescue Radar Transponders,” with Annexes, 1994...
Detail of plate and gears on center pivot. From civilian ...
Detail of plate and gears on center pivot. From civilian land. Looking north. - Naval Supply Annex Stockton, Daggett Road Bridge, Daggett Road traversing Burns Cut Off, Stockton, San Joaquin County, CA
View of steel warehouses, building 710 north sidewalk; camera facing ...
View of steel warehouses, building 710 north sidewalk; camera facing east. - Naval Supply Annex Stockton, Steel Warehouse Type, Between James & Humphreys Drives south of Embarcadero, Stockton, San Joaquin County, CA
Heller, Simon; White, David; Lee, Ellen; Lawton, Julia; Pollard, Daniel; Waugh, Norman; Amiel, Stephanie; Barnard, Katharine; Beckwith, Anita; Brennan, Alan; Campbell, Michael; Cooper, Cindy; Dimairo, Munyaradzi; Dixon, Simon; Elliott, Jackie; Evans, Mark; Green, Fiona; Hackney, Gemma; Hammond, Peter; Hallowell, Nina; Jaap, Alan; Kennon, Brian; Kirkham, Jackie; Lindsay, Robert; Mansell, Peter; Papaioannou, Diana; Rankin, David; Royle, Pamela; Smithson, W Henry; Taylor, Carolin
2017-04-01
Insulin is generally administered to people with type 1 diabetes mellitus (T1DM) using multiple daily injections (MDIs), but can also be delivered using infusion pumps. In the UK, pumps are recommended for patients with the greatest need and adult use is less than in comparable countries. Previous trials have been small, of short duration and have failed to control for training in insulin adjustment. To assess the clinical effectiveness and cost-effectiveness of pump therapy compared with MDI for adults with T1DM, with both groups receiving equivalent structured training in flexible insulin therapy. Pragmatic, multicentre, open-label, parallel-group cluster randomised controlled trial, including economic and psychosocial evaluations. After participants were assigned a group training course, courses were randomly allocated in pairs to either pump or MDI. Eight secondary care diabetes centres in the UK. Adults with T1DM for > 12 months, willing to undertake intensive insulin therapy, with no preference for pump or MDI, or a clinical indication for pumps. Pump or MDI structured training in flexible insulin therapy, followed up for 2 years. MDI participants used insulin analogues. Pump participants used a Medtronic Paradigm ® Veo TM (Medtronic, Watford, UK) with insulin aspart (NovoRapid, Novo Nordisk, Gatwick, UK). Primary outcome - change in glycated haemoglobin (HbA 1c ) at 2 years in participants whose baseline HbA 1c was ≥ 7.5% (58 mmol/mol). Key secondary outcome - proportion of participants with HbA 1c ≤ 7.5% at 2 years. Other outcomes at 6, 12 and 24 months - moderate and severe hypoglycaemia; insulin dose; body weight; proteinuria; diabetic ketoacidosis; quality of life (QoL); fear of hypoglycaemia; treatment satisfaction; emotional well-being; qualitative interviews with participants and staff (2 weeks), and participants (6 months); and ICERs in trial and modelled estimates of cost-effectiveness. We randomised 46 courses comprising 317 participants: 267 attended a Dose Adjustment For Normal Eating course (132 pump; 135 MDI); 260 were included in the intention-to-treat analysis, of which 235 (119 pump; 116 MDI) had baseline HbA 1c of ≥ 7.5%. HbA 1c and severe hypoglycaemia improved in both groups. The drop in HbA 1c % at 2 years was 0.85 on pump and 0.42 on MDI. The mean difference (MD) in HbA 1c change at 2 years, at which the baseline HbA 1c was ≥ 7.5%, was -0.24% [95% confidence interval (CI) -0.53% to 0.05%] in favour of the pump ( p = 0.098). The per-protocol analysis showed a MD in change of -0.36% (95% CI -0.64% to -0.07%) favouring pumps ( p = 0.015). Pumps were not cost-effective in the base case and all of the sensitivity analyses. The pump group had greater improvement in diabetes-specific QoL diet restrictions, daily hassle plus treatment satisfaction, statistically significant at 12 and 24 months and supported by qualitative interviews. Blinding of pump therapy was not possible, although an objective primary outcome was used. Adding pump therapy to structured training in flexible insulin therapy did not significantly enhance glycaemic control or psychosocial outcomes in adults with T1DM. To understand why few patients achieve a HbA 1c of < 7.5%, particularly as glycaemic control is worse in the UK than in other European countries. Current Controlled Trials ISRCTN61215213. This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment ; Vol. 21, No. 20. See the NIHR Journals Library website for further project information.
Shallow Carbon Export from an Iron fertilised Plankton Bloom in the Southern Ocean
NASA Astrophysics Data System (ADS)
Sanders, R.; Pollard, R.; Morris, P.; Statham, P.; Moore, C. M. M.; Lucas, M.
2009-04-01
Some regions of the global ocean, notably the Southern Ocean, have high levels of macronutrients yet low levels of chlorophyll (the high nutrient, low chlorophyll or HNLC condition). Numerous artificial iron fertilization experiments conducted in the Southern Ocean have resulted in enhanced phytoplankton biomass and macronutrient drawdown. However the subsequent long-term biogeochemical consequences of such iron fertilization are unclear due in part to the limited size and duration of such experiments. An alternative way to assess the affect of iron over the Southern Ocean biological carbon pump is to observe the evolution of plankton production in regions of the Southern Ocean where shallow topography and Ocean currents interact to promote to release terrestrial iron into HNLC waters. During 2004-5 RRS Discovery conduced a complex programme of observations in such a region around the Crozet Islands in the SW Indian Ocean. The results of this programme, focussing on a quantitative estimate of carbon export per unit iron addition, will be presented.
Controlled supercontinua via spatial beam shaping
NASA Astrophysics Data System (ADS)
Zhdanova, Alexandra A.; Shen, Yujie; Thompson, Jonathan V.; Scully, Marlan O.; Yakovlev, Vladislav V.; Sokolov, Alexei V.
2018-06-01
Recently, optimization techniques have had a significant impact in a variety of fields, leading to a higher signal-to-noise and more streamlined techniques. We consider the possibility for using programmable phase-only spatial optimization of the pump beam to influence the supercontinuum generation process. Preliminary results show that significant broadening and rough control of the supercontinuum spectrum in the visible region are possible without loss of input energy. This serves as a proof-of-concept demonstration that spatial effects can controllably influence the supercontinuum spectrum, leading to possibilities for utilizing supercontinuum power more efficiently and achieving excellent spectral control.
Measurement of viscous flow velocity and flow visualization using two magnetic resonance imagers
NASA Astrophysics Data System (ADS)
Boiko, A. V.; Akulov, A. E.; Chupakhin, A. P.; Cherevko, A. A.; Denisenko, N. S.; Savelov, A. A.; Stankevich, Yu. A.; Khe, A. K.; Yanchenko, A. A.; Tulupov, A. A.
2017-03-01
The accuracies of measuring the velocity field using clinical and research magnetic resonance imagers are compared. The flow velocity of a fluid simulating blood in a carotid artery model connected to a programmable pump was measured. Using phase-contrast magnetic resonance tomography, the velocity distributions in the carotid artery model were obtained and compared with the analytical solution for viscous liquid flow in a cylindrical tube (Poiseuille flow). It is found that the accuracy of the velocity measurement does not depend on the field induction and spatial resolution of the imagers.
Subcutaneous narcotic infusions for cancer pain: treatment outcome and guidelines for use.
Moulin, D E; Johnson, N G; Murray-Parsons, N; Geoghegan, M F; Goodwin, V A; Chester, M A
1992-03-15
To provide guidelines for the institution and maintenance of a continuous subcutaneous narcotic infusion program for cancer patients with chronic pain through an analysis of the narcotic requirements and treatment outcomes of patients who underwent such therapy and a comparison of the costs of two commonly used infusion systems. Retrospective study. Tertiary care facilities and patients' homes. Of 481 patients seen in consultation for cancer pain between July 1987 and April 1990, 60 (12%) met the eligibility criteria (i.e., standard medical management had failed, and they had adequate supervision at home). Continuous subcutaneous infusion with hydromorphone hydrochloride or morphine started on an inpatient basis and continued at home whenever possible. Patient selectivity, narcotic dosing requirements, discharge rate, patient preference for analgesic regimen, side effects, complications and cost-effectiveness. The mean initial maintenance infusion dose after dose titration was almost three times higher than the dose required before infusion (hydromorphone or equivalent 6.2 v. 2.1 mg/h). Eighteen patients died, and the remaining 42 were discharged home for a mean of 94.4 (standard deviation 128.3) days (extremes 12 and 741 days). The mean maximum infusion rate was 24.1 mg/h (extremes 0.5 and 180 mg/h). All but one of the patients preferred the infusion system to their previous oral analgesic regimen. Despite major dose escalations nausea and vomiting were well controlled in all cases. Twelve patients (20%) experienced serious systemic toxic effects or complications; six became encephalopathic, which necessitated dose reduction, five had a subcutaneous infection necessitating antibiotic treatment, and one had respiratory depression. The programmable computerized infusion pump was found to be more cost-effective than the disposable infusion device after a break-even point of 8 months. Continuous subcutaneous infusion of opioid drugs with the use of a portable programmable pump is safe and effective in selected patients who have failed to respond to standard medical treatment of their cancer pain. Dose titration may require rapid dose escalation, but this is usually well tolerated. For most communities embarking on such a program a programmable infusion system will be more cost-effective than a disposable system.
NASA Astrophysics Data System (ADS)
van der Grift, Bas; Broers, Hans Peter; Berendrecht, Wilbert; Rozemeijer, Joachim; Osté, Leonard; Griffioen, Jasper
2016-05-01
Many agriculture-dominated lowland water systems worldwide suffer from eutrophication caused by high nutrient loads. Insight in the hydrochemical functioning of embanked polder catchments is highly relevant for improving the water quality in such areas or for reducing export loads to downstream water bodies. This paper introduces new insights in nutrient sources and transport processes in a polder in the Netherlands situated below sea level using high-frequency monitoring technology at the outlet, where the water is pumped into a higher situated lake, combined with a low-frequency water quality monitoring programme at six locations within the drainage area. Seasonal trends and short-scale temporal dynamics in concentrations indicated that the NO3 concentration at the pumping station originated from N loss from agricultural lands. The NO3 loads appear as losses via tube drains after intensive rainfall events during the winter months due to preferential flow through the cracked clay soil. Transfer function-noise modelling of hourly NO3 concentrations reveals that a large part of the dynamics in NO3 concentrations during the winter months can be related to rainfall. The total phosphorus (TP) concentration and turbidity almost doubled during operation of the pumping station, which points to resuspension of particulate P from channel bed sediments induced by changes in water flow due to pumping. Rainfall events that caused peaks in NO3 concentrations did not results in TP concentration peaks. The rainfall induced and NO3 enriched quick interflow, may also be enriched in TP but retention of TP due to sedimentation of particulate P then results in the absence of rainfall induced TP concentration peaks. Increased TP concentrations associated with run-off events is only observed during a rainfall event at the end of a freeze-thaw cycle. All these observations suggest that the P retention potential of polder water systems is primarily due to the artificial pumping regime that buffers high flows. As the TP concentration is affected by operation of the pumping station, timing of sampling relative to the operating hours of the pumping station should be accounted for when calculating P export loads, determining trends in water quality, or when judging water quality status of polder water systems.
7 CFR 3300.73 - Period of validity of certificates.
Code of Federal Regulations, 2012 CFR
2012-01-01
... EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Certification of New Equipment § 3300.73 Period of validity of certificates. In accordance with ATP, Annex 1...
7 CFR 3300.73 - Period of validity of certificates.
Code of Federal Regulations, 2013 CFR
2013-01-01
... EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Certification of New Equipment § 3300.73 Period of validity of certificates. In accordance with ATP, Annex 1...
7 CFR 3300.73 - Period of validity of certificates.
Code of Federal Regulations, 2010 CFR
2010-01-01
... EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Certification of New Equipment § 3300.73 Period of validity of certificates. In accordance with ATP, Annex 1...
7 CFR 3300.73 - Period of validity of certificates.
Code of Federal Regulations, 2011 CFR
2011-01-01
... EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Certification of New Equipment § 3300.73 Period of validity of certificates. In accordance with ATP, Annex 1...
7 CFR 3300.73 - Period of validity of certificates.
Code of Federal Regulations, 2014 CFR
2014-01-01
... EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Certification of New Equipment § 3300.73 Period of validity of certificates. In accordance with ATP, Annex 1...
Bill Walker on July 29, 2015. Since that date, additional members have been annexed to include federal Executive Committee. News and Updates: Geospatial Data Act of 2017: A bill re-introduced to the Senate on
75 FR 43609 - Agency Information Collection Activities: Emergency Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-26
... SOCIAL SECURITY ADMINISTRATION Agency Information Collection Activities: Emergency Request The Social Security Administration (SSA) publishes a list of information collection packages requiring...) Social Security Administration, DCBFM, Attn: Reports Clearance Officer, 1340 Annex Building, 6401...
Center pivot, showing substantial beams that support the trusses. Looking ...
Center pivot, showing substantial beams that support the trusses. Looking north from civilian land. - Naval Supply Annex Stockton, Daggett Road Bridge, Daggett Road traversing Burns Cut Off, Stockton, San Joaquin County, CA
View of steel warehouses (building 710 second in on right); ...
View of steel warehouses (building 710 second in on right); camera facing south. - Naval Supply Annex Stockton, Steel Warehouse Type, Between James & Humphreys Drives south of Embarcadero, Stockton, San Joaquin County, CA
View of steel warehouses (building 710 second in on left); ...
View of steel warehouses (building 710 second in on left); camera facing west. - Naval Supply Annex Stockton, Steel Warehouse Type, Between James & Humphreys Drives south of Embarcadero, Stockton, San Joaquin County, CA
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-24
... Community/Meeting Room of the Washington County Annex, 806 Martinsburg Road, Salem, IN. FOR FURTHER..., Lawrence County Tourism Commission Executive Director; Gene McCracken, Lawrence County Economic Growth...
View of deck of pony truss approach span. Deck system ...
View of deck of pony truss approach span. Deck system has failed at northwest corner. Looking south. - Naval Supply Annex Stockton, Daggett Road Bridge, Daggett Road traversing Burns Cut Off, Stockton, San Joaquin County, CA
78 FR 79078 - Unblocking of One Individual Pursuant to Executive Order 13224
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-27
... Commit, or Support Terrorism, from the list of Specially Designated Nationals and Blocked Persons (``SDN... who commit, threaten to commit, or support acts of terrorism. The President identified in the Annex to...
7 CFR 3300.61 - Testing and verification requirements.
Code of Federal Regulations, 2012 CFR
2012-01-01
... THE SPECIAL EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF... accordance with ATP, Annex 1, Appendix 1, paragraphs 1, 1(a), 2(a), 2(b), 2(c) and 3, and Appendix 2...
7 CFR 3300.61 - Testing and verification requirements.
Code of Federal Regulations, 2011 CFR
2011-01-01
... THE SPECIAL EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF... accordance with ATP, Annex 1, Appendix 1, paragraphs 1, 1(a), 2(a), 2(b), 2(c) and 3, and Appendix 2...
7 CFR 3300.61 - Testing and verification requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... THE SPECIAL EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF... accordance with ATP, Annex 1, Appendix 1, paragraphs 1, 1(a), 2(a), 2(b), 2(c) and 3, and Appendix 2...
7 CFR 3300.61 - Testing and verification requirements.
Code of Federal Regulations, 2014 CFR
2014-01-01
... THE SPECIAL EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF... accordance with ATP, Annex 1, Appendix 1, paragraphs 1, 1(a), 2(a), 2(b), 2(c) and 3, and Appendix 2...
7 CFR 3300.61 - Testing and verification requirements.
Code of Federal Regulations, 2013 CFR
2013-01-01
... THE SPECIAL EQUIPMENT TO BE USED FOR SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF... accordance with ATP, Annex 1, Appendix 1, paragraphs 1, 1(a), 2(a), 2(b), 2(c) and 3, and Appendix 2...
35. EAST FRONT OF POWERHOUSE AND CAR BARN: East front ...
35. EAST FRONT OF POWERHOUSE AND CAR BARN: East front of powerhouse and car barn. 'Annex' is right end of building. - San Francisco Cable Railway, Washington & Mason Streets, San Francisco, San Francisco County, CA
75 FR 29797 - Agency Information Collection Activities: Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-27
... SOCIAL SECURITY ADMINISTRATION Agency Information Collection Activities: Comment Request The Social Security Administration (SSA) publishes a list of information collection packages requiring... . (SSA) Social Security Administration, DCBFM, Attn: Director, Center for Reports Clearance, 1333 Annex...
4. CENTER COURTYARD, FROM WEST SIDE OF SOUTHEAST PORTION OF ...
4. CENTER COURTYARD, FROM WEST SIDE OF SOUTHEAST PORTION OF BUILDING, LOOKING WEST. - Oakland Naval Supply Center, Administration Building-Dental Annex-Dispensary, Between E & F Streets, East of Third Street, Oakland, Alameda County, CA
1. WEST SIDE AND ENTRY, FROM ACROSS 3RD STREET, LOOKING ...
1. WEST SIDE AND ENTRY, FROM ACROSS 3RD STREET, LOOKING EAST. - Oakland Naval Supply Center, Administration Building-Dental Annex-Dispensary, Between E & F Streets, East of Third Street, Oakland, Alameda County, CA
7. INTERIOR, KITCHEN SOUTH OF CENTRAL EASTWEST CORRIDOR, FROM ENTRY, ...
7. INTERIOR, KITCHEN SOUTH OF CENTRAL EAST-WEST CORRIDOR, FROM ENTRY, LOOKING SOUTH. - Oakland Naval Supply Center, Administration Building-Dental Annex-Dispensary, Between E & F Streets, East of Third Street, Oakland, Alameda County, CA
2. SOUTH SIDE, FROM PARK ACROSS PARKING LOT/F STREET, LOOKING ...
2. SOUTH SIDE, FROM PARK ACROSS PARKING LOT/F STREET, LOOKING NORTH. - Oakland Naval Supply Center, Administration Building-Dental Annex-Dispensary, Between E & F Streets, East of Third Street, Oakland, Alameda County, CA
Leaks to the Press as Communication within and between Organizations.
ERIC Educational Resources Information Center
Kielbowicz, Richard B.
1980-01-01
Examines news leaks--the calculated release of information by anonymous officials--as a means by which the mass media have been annexed to perform some of the functions of organizational and interorganizational communication. (RL)
6. INTERIOR OF THE MAIN EQUIPMENT ROOM, AN/FPS66 ALPHA, BUILDING ...
6. INTERIOR OF THE MAIN EQUIPMENT ROOM, AN/FPS66 ALPHA, BUILDING 408, LOOKING WEST. - Mill Valley Air Force Station, Operations Building & Annex, East Ridgecrest Boulevard, Mount Tamalpais, Mill Valley, Marin County, CA
Code of Federal Regulations, 2011 CFR
2011-07-01
... full range of protections contained in § 154.56(b) or, in the case of SCI, Annex B, DCID 1/14. (2) The... period for TOP SECRET/SCI or within the period prevailing for SECRET clearances under departmental policy...
33 CFR 155.380 - Oily water separating equipment and bilge alarm approval standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION OIL OR HAZARDOUS MATERIAL POLLUTION... § 155.380(b): A copy of Annex I to the International Convention for the Prevention of Pollution from...
Detail of metal caisson and decking system on pony truss ...
Detail of metal caisson and decking system on pony truss span. From navy land. Looking southeast. - Naval Supply Annex Stockton, Daggett Road Bridge, Daggett Road traversing Burns Cut Off, Stockton, San Joaquin County, CA
View of one half of movable span, showing truss and ...
View of one half of movable span, showing truss and tension bars, from navy land looking southwest. - Naval Supply Annex Stockton, Daggett Road Bridge, Daggett Road traversing Burns Cut Off, Stockton, San Joaquin County, CA
View of steel warehouses at Gilmore Avenue (building 710 second ...
View of steel warehouses at Gilmore Avenue (building 710 second in on left); camera facing east. - Naval Supply Annex Stockton, Steel Warehouse Type, Between James & Humphreys Drives south of Embarcadero, Stockton, San Joaquin County, CA
View of steel warehouses on Ellsberg Drive, building 710 full ...
View of steel warehouses on Ellsberg Drive, building 710 full building at center; camera facing southeast. - Naval Supply Annex Stockton, Steel Warehouse Type, Between James & Humphreys Drives south of Embarcadero, Stockton, San Joaquin County, CA
View of steel warehouses (from left: building 807, 808, 809, ...
View of steel warehouses (from left: building 807, 808, 809, 810, 811); camera facing east. - Naval Supply Annex Stockton, Steel Warehouse Type, Between James & Humphreys Drives south of Embarcadero, Stockton, San Joaquin County, CA
15 CFR Supplement No. 3 to Part 760 - Interpretation
Code of Federal Regulations, 2011 CFR
2011-01-01
... Article 2, Annex II of the Peace Treaty between Egypt and Israel, Egypt's participation in the Arab... vessel on which it is shipping its goods is eligible to enter Arab Republic of Egypt ports has been...
15 CFR Supplement No. 3 to Part 760 - Interpretation
Code of Federal Regulations, 2012 CFR
2012-01-01
... Article 2, Annex II of the Peace Treaty between Egypt and Israel, Egypt's participation in the Arab... vessel on which it is shipping its goods is eligible to enter Arab Republic of Egypt ports has been...
15 CFR Supplement No. 3 to Part 760 - Interpretation
Code of Federal Regulations, 2013 CFR
2013-01-01
... Article 2, Annex II of the Peace Treaty between Egypt and Israel, Egypt's participation in the Arab... vessel on which it is shipping its goods is eligible to enter Arab Republic of Egypt ports has been...
15 CFR Supplement No. 3 to Part 760 - Interpretation
Code of Federal Regulations, 2014 CFR
2014-01-01
... Article 2, Annex II of the Peace Treaty between Egypt and Israel, Egypt's participation in the Arab... vessel on which it is shipping its goods is eligible to enter Arab Republic of Egypt ports has been...
77 FR 16204 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-20
... Korea negotiated the U.S.- Korea Free Trade Agreement (the ``Agreement''), which entered into force on March 15, 2012. Subject to the rules of origin in Annex 4-A of the Agreement, pursuant to the provisions...
Craig, Adam; Kool, Jacob; Nilles, Eric
2013-01-01
By 15 June 2012, States Parties to the International Health Regulations (2005), or IHR (2005), were required to have established the core capacities required to implement Annex 1 of IHR (2005). The Pacific is home to 10 million people spread over 21 Pacific island countries and territories. Seven of those have populations of less than 25 000 people; 14 of the 21 Pacific island countries and territories are States Parties to the IHR (2005). The World Health Organization Division of the South Pacific embarked on an initiative to support Pacific Island States Parties meet their 15 June 2012 IHR obligations. We adapted the 2012 IHR Monitoring Questionnaire (IHRMQ) to assist Pacific island countries and territories determine if they had met the capacities required to implement Annex 1 of the IHR (2005). If a Pacific island country or territory determined that it had not yet met the requirements, it could use the assessment outcome to develop a plan to address identified gaps. Direct support was provided to 19 of 21 (91%) Pacific island countries and territories including 13 of 14 (93%) States Parties. Twelve of 14 (86%) fulfilled their requirements by 15 June 2012; those that had not yet met the requirements requested extensions and submitted plans describing how the IHR core capacities would be met. Adapting the 2012 IHRMQ for this purpose provided an efficient tool for assessing national capacity to implement Annex 1 of IHR (2005) and provided clear indication of what capacities required strengthening.
Comparative study of diastolic filling under varying left ventricular wall stiffness
NASA Astrophysics Data System (ADS)
Mekala, Pritam; Santhanakrishnan, Arvind
2014-11-01
Pathological remodeling of the human cardiac left ventricle (LV) is observed in hypertensive heart failure as a result of pressure overload. Myocardial stiffening occurs in these patients prior to chronic maladaptive changes, resulting in increased LV wall stiffness. The goal of this study was to investigate the change in intraventricular filling fluid dynamics inside a physical model of the LV as a function of wall stiffness. Three LV models of varying wall stiffness were incorporated into an in vitro flow circuit driven by a programmable piston pump. Windkessel elements were used to tune the inflow and systemic pressure in the model with least stiffness to match healthy conditions. Models with stiffer walls were comparatively tested maintaining circuit compliance, resistance and pump amplitude constant. 2D phase-locked PIV measurements along the central plane showed that with increase in wall stiffness, the peak velocity and cardiac output inside the LV decreased. Further, inflow vortex ring propagation toward the LV apex was reduced with increasing stiffness. The above findings indicate the importance of considering LV wall relaxation characteristics in pathological studies of filling fluid dynamics.
75 FR 30847 - Federal Property Suitable as Facilities To Assist the Homeless
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-02
...., presence of asbestos/lead paint, off-site use only Belmont Cty Memorial USAR Ctr 5305 Guernsey St. Bellaire... presence of asbestos Land Missouri Annex No. 3 Whiteman AFB Knob Noster MO 65336 Landholding Agency: Air...
5. SOUTHEAST CORNER AND COURTYARD OPENING, FROM F STREET SIDEWALK ...
5. SOUTHEAST CORNER AND COURTYARD OPENING, FROM F STREET SIDEWALK SOUTHEAST OF BUILDING, LOOKING NORTH-NORTHWEST. - Oakland Naval Supply Center, Administration Building-Dental Annex-Dispensary, Between E & F Streets, East of Third Street, Oakland, Alameda County, CA
6. NORTH SIDE, FROM APPROXIMATELY 25 FEET SOUTHEAST OF SOUTHWEST ...
6. NORTH SIDE, FROM APPROXIMATELY 25 FEET SOUTHEAST OF SOUTHWEST CORNER OF BUILDING 320, LOOKING SOUTH. - Oakland Naval Supply Center, Administration Building-Dental Annex-Dispensary, Between E & F Streets, East of Third Street, Oakland, Alameda County, CA
Ship Technology Workshop Materials from Collaboration with Mexico to Reduce Emissions from Ships
On September 26, 2012, a ship technology seminar was held to provide Mexican stakeholders with information about some of the ship technologies needed to meet the requirements of MARPOL Annex VI and an ECA.
SLS Intertank Test Article, ITA, is attached to crosshead of loa
2018-04-04
SLS Intertank Test Article, ITA, is attached to crosshead of load test Annex, Bldg. 4619, and removed from bed of KMAG transporter. ITA is slowly raised from bed of KMAG transporter and KMAG is removed.
14 CFR 91.703 - Operations of civil aircraft of U.S. registry outside of the United States.
Code of Federal Regulations, 2010 CFR
2010-01-01
.... In addition, Annex 2 may be purchased from the International Civil Aviation Organization (Attention: Distribution Officer), P.O. Box 400, Succursale, Place de L'Aviation Internationale, 1000 Sherbrooke Street...
9. VIEW, LOOKING NORTH FROM LEFT TO RIGHT, SHOWING MEDICAL ...
9. VIEW, LOOKING NORTH FROM LEFT TO RIGHT, SHOWING MEDICAL RESEARCH LABORATORY ANNEX, EXAMINING ROOM, AND EQUIPMENT ROOM - U.S. Naval Submarine Base, New London Submarine Escape Training Tank, Albacore & Darter Roads, Groton, New London County, CT
Detail of "pin" or large bolt used to assemble the ...
Detail of "pin" or large bolt used to assemble the truss pieces. This "pin" is on pony truss; similar pins were used on movable span. - Naval Supply Annex Stockton, Rough & Ready Island, Stockton, San Joaquin County, CA
Noise Levels for U.S. Certificated and Foreign Aircraft
DOT National Transportation Integrated Search
2001-11-11
This circular provides noise level data for aircraft certificated under 14 CFR : part 36. Noise level data for foreign aircraft certificated to ICAO Annex 16 : standards are also provided in a separate appendix for informational purposes. : Other app...
TECHNICAL SUPPORT FOR RADIOLOGICAL EMERGENCY PROTECTION ACTION RECOMMENDATIONS
RPD staff provide techical support for other EPA offices, other Federal departments and agencies and to state and local governments in preparing for and responding to radiological and nuclear emergencies under the National Response Framework's Nuclear/Radiological Incident Annex....
Device and method for measuring the energy content of hot and humid air streams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosen, H. N.; Girod, G. F.; Kent, A. C.
1985-12-24
a portable device and method for measuring enthalpy and humidity of humid air from a space or flow channel at temperatures from 80/sup 0/ to 400/sup 0/ F. is described. the device consists of a psychrometer for measuring wet-bulb temperature, a vacuum pump for inducing sample air flow through the unit, a water-heating system for accurate psychrometer readings, an electronic computer system for evaluation of enthalpy and humidity from corrected and averaged values of wet- and dry- bulb temperatures, and a monitor for displaying the values. The device is programmable by the user to modify evaluation methods as necessary.
Ruan, Xiulu; Couch, J Patrick; Liu, HaiNan; Shah, Rinoo V; Wang, Frank; Chiravuri, Srinivas
2010-01-01
Spinal analgesia, mediated by opioid receptors, requires only a fraction of the opioid dose that is needed systemically. By infusing a small amount of opioid into the cerebrospinal fluid in close proximity to the receptor sites in the spinal cord, profound analgesia may be achieved while sparing some of the side effects due to systemic opioids. Intraspinal drug delivery (IDD) has been increasingly used in patients with intractable chronic pain, when these patients have developed untoward side effects with systemic opioid usage. The introduction of intrathecal opioids has been considered one of the most important breakthroughs in pain management in the past three decades. A variety of side effects associated with the long-term usage of IDD have been recognized. Among them, respiratory depression is the most feared. To describe a severe adverse event, i.e., respiratory failure, following delayed intrathecal morphine pump refill. A 65-year-old woman with intractable chronic low back pain, due to degenerative disc disease, and was referred to our clinic for an intraspinal drug delivery evaluation, after failing to respond to multidisciplinary pain treatment. Following a psychological evaluation confirming her candidacy, she underwent an outpatient patient-controlled continuous epidural morphine infusion trial. The infusion trial lasted 12 days and was beneficial in controlling her pain. The patient reported more than 90% pain reduction with improved distance for ambulation. She subsequently consented and was scheduled for permanent intrathecal morphine pump implantation. The intrathecal catheter was inserted at right paramedian L3-L4, with catheter tip advanced to L1, confirmed under fluoroscopy. Intrathecal catheter placement was confirmed by positive CSF flow and by myelogram. A non-programmable Codman 3000 constant-flow rate infusion pump was placed in the right mid quandrant between right rib cage and right iliac crest. The intrathecal infusion consisted of preservative free morphine, delivering 1.0 mg /day. Over the following 6 months, the dosage was gradually titrated up to 4 mg/day with satisfactory pain control without significant side effects. However, the patient was not able to return to the clinic for pump refill until 12 days later than the previously scheduled pump-refill date. Her pump was accessed and was noted to be empty. Her intrathecal pump was refilled with preservative free morphine, delivering 4 mg/day (the same daily dose as her previous refill). However, on the night of pump refill, 10 hours after the pump refill, the patient was found to be unresponsive by her family members. 911 was called. Upon arriving, paramedics found her in respiratory failure, with shallow breathing at a rate of 5/min, pulse oxymetry showing oxygen saturation about 55-58%. She was emergently intubated on site and rushed to local hospital ER. The on call physician for our clinic was immediately contacted, and advised the administration of intravenous Naloxone. Her respiratory effort improved dramatically after receiving a total of 0.6 mg IV Naloxone IV over 25 minutes. Her intrathecal pump was immediately accessed by clinic on call physician and the remainder of the medication in the catheter space was aspirated. The pump infusate was immediately diluted with preservative free normal saline, to deliver preservative free morphine at 1mg/day. She was transferred to the intensive care unit and extubated the next morning. She recovered fully without any sequelae. Loss of opioid tolerance due to delayed pump refill may subject patients to the development of severe respiratory depression. Meticulous approach should be employed when refilling pumps in these patients when their pumps are completely empty. To our knowledge, this is the first reported case of this type.
ERIC Educational Resources Information Center
Piele, Philip K.
Several court cases involving acquisition, use, and disposal of property by institutions of higher education are briefly summarized in this chapter. Cases discussed touch on such topics as municipal annexation of university property; repurchase of properties temporarily allocated to faculty members; implications of zoning laws and zoning board…
Code of Federal Regulations, 2010 CFR
2010-04-01
... law the provisions of the following agreements annexed to the Agreement Establishing the World Trade Organization: Agreement on Implementation of Article VI of the General Agreement on Tariffs and Trade 1994... INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Scope and...
Code of Federal Regulations, 2013 CFR
2013-01-01
... test fuel that meets the specifications described in Appendix 4 of ICAO Annex 16. The test fuel must... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT FUEL VENTING AND EXHAUST EMISSION REQUIREMENTS FOR TURBINE ENGINE POWERED AIRPLANES Test Procedures for Engine Exhaust...
Link to Federal Register Notice from February 19, 2015 announcing Amendments Related to: Tier 3 Motor Vehicle Emission and Fuel Standards, Nonroad Engine and Equipment Programs, and MARPOL Annex VI Implementation.
The SLS Stages Intertank Structural Test Assembly (STA) arrives at MSFC.
2018-03-06
The SLS Stages Intertank Structural Test Assembly (STA) is rolling off the NASA Pegasus Barge at the MSFC Dock enroute to the MSFC 4619 Load Test Annex test facility for qualification testing. STA emerges from Barge Pegasus.
Vessel Sewage Discharges: Statutes, Regulations, and Related Laws and Treaties
Vessel sewage discharges can be regulated under multiple statutes, regulations, and laws/treaties, including the Clean Water Act, Title XIV, MARPOL Annex IV and the Vessel General Permit. This page describes how these are applied to vessel sewage.
View of movable span and point truss (to right), from ...
View of movable span and point truss (to right), from navy land, looking west, showing bridge in context of navigational channel. - Naval Supply Annex Stockton, Daggett Road Bridge, Daggett Road traversing Burns Cut Off, Stockton, San Joaquin County, CA
11. VIEW, LOOKING EAST FROM LEFT TO RIGHT, SHOWING UNDERWATER ...
11. VIEW, LOOKING EAST FROM LEFT TO RIGHT, SHOWING UNDERWATER WELDING/SCUBA ROOM, CLASSROOM BUILDING, AND MEDICAL RESEARCH LABORATORY ANNEX - U.S. Naval Submarine Base, New London Submarine Escape Training Tank, Albacore & Darter Roads, Groton, New London County, CT
76 FR 18149 - Codex Alimentarius Commission: Meeting of the Codex Committee on Food Labeling
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-01
... organically produced foods. (a) Annex 1: Inclusion of ethylene for other products at Step 7. Use of ethylene... ethylene for de-greening of citrus fruit, induction of flowering in pineapples and sprout inhibition in...
78 FR 6399 - Shipping Coordinating Committee; Notice of Committee Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-30
... DEPARTMENT OF STATE [Public Notice 8172] Shipping Coordinating Committee; Notice of Committee... amendments to the Convention --General review of the Convention, including harmonization with other international instruments: A. Comprehensive review of the Annex to the Convention, including: Intersessional...
Maghami, Mohammad Hossein; Sodagar, Amir M; Sawan, Mohamad
2016-11-01
This paper reports on the design, implementation, and test of a stimulation back-end, for an implantable retinal prosthesis. In addition to traditional rectangular pulse shapes, the circuit features biphasic stimulation pulses with both rising and falling exponential shapes, whose time constants are digitally programmable. A class-B second generation current conveyor is used as a wide-swing, high-output-resistance stimulation current driver, delivering stimulation current pulses of up to ±96 μA to the target tissue. Duration of the generated current pulses is programmable within the range of 100 μs to 3 ms. Current-mode digital-to-analog converters (DACs) are used to program the amplitudes of the stimulation pulses. Fabricated using the IBM 130 nm process, the circuit consumes 1.5×1.5 mm 2 of silicon area. According to the measurements, the DACs exhibit DNL and INL of 0.23 LSB and 0.364 LSB, respectively. Experimental results indicate that the stimuli generator meets expected requirements when connected to electrode-tissue impedance of as high as 25 k Ω. Maximum power consumption of the proposed design is 3.4 mW when delivering biphasic rectangular pulses to the target load. A charge pump block is in charge of the upconversion of the standard 1.2-V supply voltage to ±3.3V.
Heller, Simon; White, David; Lee, Ellen; Lawton, Julia; Pollard, Daniel; Waugh, Norman; Amiel, Stephanie; Barnard, Katharine; Beckwith, Anita; Brennan, Alan; Campbell, Michael; Cooper, Cindy; Dimairo, Munyaradzi; Dixon, Simon; Elliott, Jackie; Evans, Mark; Green, Fiona; Hackney, Gemma; Hammond, Peter; Hallowell, Nina; Jaap, Alan; Kennon, Brian; Kirkham, Jackie; Lindsay, Robert; Mansell, Peter; Papaioannou, Diana; Rankin, David; Royle, Pamela; Smithson, W Henry; Taylor, Carolin
2017-01-01
BACKGROUND Insulin is generally administered to people with type 1 diabetes mellitus (T1DM) using multiple daily injections (MDIs), but can also be delivered using infusion pumps. In the UK, pumps are recommended for patients with the greatest need and adult use is less than in comparable countries. Previous trials have been small, of short duration and have failed to control for training in insulin adjustment. OBJECTIVE To assess the clinical effectiveness and cost-effectiveness of pump therapy compared with MDI for adults with T1DM, with both groups receiving equivalent structured training in flexible insulin therapy. DESIGN Pragmatic, multicentre, open-label, parallel-group cluster randomised controlled trial, including economic and psychosocial evaluations. After participants were assigned a group training course, courses were randomly allocated in pairs to either pump or MDI. SETTING Eight secondary care diabetes centres in the UK. PARTICIPANTS Adults with T1DM for > 12 months, willing to undertake intensive insulin therapy, with no preference for pump or MDI, or a clinical indication for pumps. INTERVENTIONS Pump or MDI structured training in flexible insulin therapy, followed up for 2 years. MDI participants used insulin analogues. Pump participants used a Medtronic Paradigm(®) Veo(TM) (Medtronic, Watford, UK) with insulin aspart (NovoRapid, Novo Nordisk, Gatwick, UK). MAIN OUTCOME MEASURES Primary outcome - change in glycated haemoglobin (HbA1c) at 2 years in participants whose baseline HbA1c was ≥ 7.5% (58 mmol/mol). Key secondary outcome - proportion of participants with HbA1c ≤ 7.5% at 2 years. Other outcomes at 6, 12 and 24 months - moderate and severe hypoglycaemia; insulin dose; body weight; proteinuria; diabetic ketoacidosis; quality of life (QoL); fear of hypoglycaemia; treatment satisfaction; emotional well-being; qualitative interviews with participants and staff (2 weeks), and participants (6 months); and ICERs in trial and modelled estimates of cost-effectiveness. RESULTS We randomised 46 courses comprising 317 participants: 267 attended a Dose Adjustment For Normal Eating course (132 pump; 135 MDI); 260 were included in the intention-to-treat analysis, of which 235 (119 pump; 116 MDI) had baseline HbA1c of ≥ 7.5%. HbA1c and severe hypoglycaemia improved in both groups. The drop in HbA1c% at 2 years was 0.85 on pump and 0.42 on MDI. The mean difference (MD) in HbA1c change at 2 years, at which the baseline HbA1c was ≥ 7.5%, was -0.24% [95% confidence interval (CI) -0.53% to 0.05%] in favour of the pump (p = 0.098). The per-protocol analysis showed a MD in change of -0.36% (95% CI -0.64% to -0.07%) favouring pumps (p = 0.015). Pumps were not cost-effective in the base case and all of the sensitivity analyses. The pump group had greater improvement in diabetes-specific QoL diet restrictions, daily hassle plus treatment satisfaction, statistically significant at 12 and 24 months and supported by qualitative interviews. LIMITATION Blinding of pump therapy was not possible, although an objective primary outcome was used. CONCLUSION Adding pump therapy to structured training in flexible insulin therapy did not significantly enhance glycaemic control or psychosocial outcomes in adults with T1DM. RESEARCH PRIORITY To understand why few patients achieve a HbA1c of < 7.5%, particularly as glycaemic control is worse in the UK than in other European countries. TRIAL REGISTRATION Current Controlled Trials ISRCTN61215213. FUNDING This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 21, No. 20. See the NIHR Journals Library website for further project information. PMID:28440211
Hautier-Suply, Olivia; Friedmann, Yasmin; Shapley, Julian
2018-04-01
Technological advances have led to innovative insulin delivery systems for patients with type 1 diabetes mellitus. In particular, the combination of miniature engineering and software algorithms contained in continuous subcutaneous insulin infusion (CSII) system pumps provide the user and the healthcare practitioner with an opportunity to review and adjust blood glucose (BG) levels according to system feedback, and to modify or programme their regimen according to their needs. While CSII pumps record a number of data parameters such as BG level, carbohydrate intake, activity and insulin delivered, these data are generally 'locked in' and can only be accessed by uploading to a cloud-based system, thus information is not contemporaneous. The Cellnovo Diabetes Management System (Cellnovo, Bridgend, UK) allows data to be transmitted securely and wirelessly in real time to a secure server, which is then retrieved by an online platform, the Cellnovo Online platform, enabling continuous access by the user and by clinicians. In this article, the authors describe a retrospective review of the patient data automatically uploaded to the Cellnovo Online platform. Baseline clinical and demographic characteristics collected at the start of pump therapy are shown for all patients, and BG data from a sub-cohort of patients who have been using the system for at least 6 months and who take and record an average of three BG level tests per day are presented to demonstrate glycaemic data over time.
NASA Astrophysics Data System (ADS)
Hellwig, Tim; Brinkmann, Maximilian; Fallnich, Carsten
2018-02-01
We present a femtosecond fiber-based optical parametric oscillator (FOPO) for multiphoton microscopy with wavelength tuning by electronic repetition rate tuning in combination with a dispersive filter in the FOPO cavity. The all-spliced, all-fiber FOPO cavity is based on polarization-maintaining fibers and a broadband output coupler, allowing to get access to the resonant signal pulses as well as the idler pulses simultaneously. The system was pumped by a gain-switched fiber-coupled laser diode emitting pulses at a central wavelength of 1030 nm and an electronically tunable repetition frequency of about 2 MHz. The pump pulses were amplified in an Ytterbium fiber amplifier system with a pulse duration after amplification of 13 ps. Tuning of the idler (1140 nm - 1300 nm) and signal wavelengths (850 nm - 940 nm) was achieved by changing the repetition frequency of the pump laser by about 4 kHz. The generated signal pulses reached a pulse energy of up to 9.2 nJ at 920 nm and were spectrally broadened to about 6 nm in the FOPO by a combination of self-phase and cross-phase modulation. We showed external compression of the idler pulses at 920 nm to about 430 fs and appleid them to two-photon excitation microscopy with green fluorescent dyes. The presented system constitutes an important step towards a fully fiber-integrated all-electronically tunable and, thereby, programmable light source and already embodies a versatile and flexible light source for applications, e.g., for smart microscopy.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-23
... Texts for Use in the International Conference on Harmonisation Regions; Annex 13 on Bulk Density and... availability of a draft guidance entitled ``Q4B Evaluation and Recommendation of Pharmacopoeial Texts for Use...
78 FR 13761 - Designation of One Entity Pursuant to Executive Order 13448
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-28
... branches, of the persons listed in the Annex to E.O. 13448, as well as those persons determined by the..., Burma; No. 1 Ywama Curve, Ba Yint Naung Road, Block (2), Hlaing Township, Yangon, Burma; SWIFT/BIC AYAB...
2003-03-01
facility and Mr. Joseph Talnagi of the Ohio State Research Reactor facility for their personal guidance and insight into reactor dosimetry and neutron...62 Test C1: Dosimetry ..................................................................................................... 63 Special...66 Annex A-3. Preliminary Dosimetry Calculations
8. INTERIOR, EMERGENCY ROOM, NORTHEAST OF MAIN CORRIDOR INTERSECTION (NEAR ...
8. INTERIOR, EMERGENCY ROOM, NORTHEAST OF MAIN CORRIDOR INTERSECTION (NEAR WESTERN, MAIN ENTRY), FROM ENTRY IN NORTHWESTERN CORNER, LOOKING SOUTHEAST. - Oakland Naval Supply Center, Administration Building-Dental Annex-Dispensary, Between E & F Streets, East of Third Street, Oakland, Alameda County, CA
3. SOUTH SIDE, OBLIQUE VIEW, FROM F STREET SIDEWALK, LOOKING ...
3. SOUTH SIDE, OBLIQUE VIEW, FROM F STREET SIDEWALK, LOOKING NORTHWEST, WITH BUILDING 222 ACROSS 3RD STREET AT LEFT. - Oakland Naval Supply Center, Administration Building-Dental Annex-Dispensary, Between E & F Streets, East of Third Street, Oakland, Alameda County, CA
22. Photocopy of photograph (original print in files of Theatre ...
22. Photocopy of photograph (original print in files of Theatre Historical Society, P.O. Box 101, Notre Dame, IN 46556) Photographer unknown 1938 TREMONT STREET ANNEX, LOOKING SOUTHEAST - B. F. Keith Memorial Theatre, 539 Washington Street, Boston, Suffolk County, MA
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-11
... political subunits within a covered jurisdiction (e.g., counties, cities, school districts) that have not... information: (1) The present and expected future use of the annexed land (e.g., garden apartments, industrial...
49 CFR 173.301b - Additional general requirements for shipment of UN pressure receptacles.
Code of Federal Regulations, 2010 CFR
2010-10-01
... accordance with Annex B of ISO 10297; (v) By enclosing the UN pressure receptacles in frames, e.g., bundles...) Hydrogen bearing gases. A steel UN pressure receptacle bearing an “H” mark must be used for hydrogen...
NDCEE Annual Technologies Publication
2004-07-01
LCAAP), Independence, Missouri Lone Star Army Ammunition Plant (LSAAP), Texarkana , Texas Marine Corps Logistics Base, Yermo Annex, Barstow...100-101, 117, 123, 186, 210, 251, 258, 285, 291; 200-312, 337, 339, 852; 800-801; 900- 909, 1956, 1989, 2016, 2017 , 2018, 2019, 2021, 2089, 2097, 2106
75 FR 20372 - Certificate of Alternative Compliance for the Offshore Supply Vessel RIG RUNNER
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-19
... masthead light at the height as required by Annex I, paragraph 2(a) of the 72 COLREGS would result in a... Certificate of Alternative Compliance allows for the vertical placement of the forward masthead light to...
Lin, Kuang-Wei; Hall, Timothy L; Xu, Zhen; Cain, Charles A
2015-08-01
When histotripsy pulses shorter than 2 cycles are applied, the formation of a dense bubble cloud relies only on the applied peak negative pressure (p-) exceeding the "intrinsic threshold" of the medium (absolute value of 26-30 MPa in most soft tissues). It has been found that a sub-threshold high-frequency probe pulse (3 MHz) can be enabled by a sub-threshold low-frequency pump pulse (500 kHz) where the sum exceeds the intrinsic threshold, thus generating lesion-producing dense bubble clouds ("dual-beam histotripsy"). Here, the feasibility of using an imaging transducer to provide the high-frequency probe pulse in the dual-beam histotripsy approach is investigated. More specifically, an ATL L7-4 imaging transducer (Philips Healthcare, Andover, MA, USA), pulsed by a V-1 Data Acquisition System (Verasonics, Redmond, WA, USA), was used to generate the high-frequency probe pulses. The low-frequency pump pulses were generated by a 20-element 345-kHz array transducer, driven by a custom high-voltage pulser. These dual-beam histotripsy pulses were applied to red blood cell tissue-mimicking phantoms at a pulse repetition frequency of 1 Hz, and optical imaging was used to visualize bubble clouds and lesions generated in the red blood cell phantoms. The results indicated that dense bubble clouds (and resulting lesions) were generated when the p- of the sub-threshold pump and probe pulses combined constructively to exceed the intrinsic threshold. The average size of the smallest reproducible lesions using the imaging probe pulse enabled by the sub-threshold pump pulse was 0.7 × 1.7 mm, whereas that using the supra-threshold pump pulse alone was 1.4 × 3.7 mm. When the imaging transducer was steered laterally, bubble clouds and lesions were steered correspondingly until the combined p- no longer exceeded the intrinsic threshold. These results were also validated with ex vivo porcine liver experiments. Using an imaging transducer for dual-beam histotripsy can have two advantages: (i) lesion steering can be achieved using the steering of the imaging transducer (implemented with the beamformer of the accompanying programmable ultrasound system), and (ii) treatment can be simultaneously monitored when the imaging transducer is used in conjunction with an ultrasound imaging system. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Lin, Kuang-Wei; Hall, Timothy L.; Xu, Zhen; Cain, Charles A.
2015-01-01
When applying histotripsy pulses shorter than 2 cycles, the formation of a dense bubble cloud only relies on the applied peak negative pressure (p-) exceeding the “intrinsic threshold” of the medium (absolute value of 26 – 30 MPa in most soft tissue). A previous study conducted by our research group showed that a sub-threshold high-frequency probe pulse (3 MHz) can be enabled by a sub-threshold low-frequency pump pulse (500 kHz) where the sum exceeds the intrinsic threshold, thus generating lesion-producing dense bubble clouds (“dual-beam histotripsy”). This paper investigates the feasibility of using an imaging transducer to provide the high-frequency probe pulse in the dual-beam histotripsy approach. More specifically, an ATL L7–4 imaging transducer, pulsed by a Verasonics V-1 Data Acquisition System, was used to generate the high-frequency probe pulses. The low-frequency pump pulses were generated by a 20-element 345 kHz array transducer, driven by a custom high voltage pulser. These dual-beam histotripsy pulses were applied to red-blood-cell (RBC) tissue-mimicking phantoms at a pulse repetition frequency of 1 Hz, and optical imaging was used to visualize bubble clouds and lesions generated in the RBC phantoms. The results showed that dense bubble clouds (and resulting lesions) were generated when the p- of the sub-threshold pump and probe pulses combined constructively to exceed the intrinsic threshold. The average size of the smallest reproducible lesions using the imaging probe pulse enabled by the sub-threshold pump pulse was 0.7 × 1.7 mm while that using the supra-threshold pump pulse alone was 1.4 × 3.7 mm. When the imaging transducer was steered laterally, bubble clouds and lesions were steered correspondingly until the combined p- no longer exceeded the intrinsic threshold. These results were also validated with ex vivo porcine liver experiments. Using an imaging transducer for dual-beam histotripsy can have two advantages, 1) lesion steering can be achieved using the steering of the imaging transducer (implemented with the beamformer of the accompanying programmable ultrasound system) and 2) treatment can be simultaneously monitored when the imaging transducer is used in conjunction with an ultrasound imaging system. PMID:25929995
Torsion d'annexe au second trimestre de la grossesse, à propos de deux cas
Ayachi, Amira; Blel, Zeineb; Khelifa, Nahed; Mkaouer, Lassaad; Bouchahda, Rim; Mourali, Mechaal
2016-01-01
Les douleurs pelviennes aigues pendant la grossesse peuvent poser un problème de diagnostic différentiel.Nous rapportons deux cas de torsion d'annexes au deuxième trimestre de la grossesse afin d'attirer l'attention sur ce diagnostic, dont seule une prise en charge précoce permet d'éviter des lésions irréversibles dues à l'ischémie, pouvant mettre en jeu le pronostic ultérieur de fertilité. La première patiente, G1P0, enceinte à 20 SA, s'est présenté initialement pour un syndrome appendiculaire. Une incision de Mac Burney, au cours de l'exploration, a montré un ovaire droit nécrosé et une ovariectomie a été faite. Les suites post opératoires étaient simples. La seconde patiente, G2P2, s'est présenté aux urgences avec des douleurs aigues de la fosse iliaque gauche à 26 SA. La laparotomie a mis en évidence une torsion d'une hydatide de Morgani, dont l'aspect nécrosé dû à une torsion, a orienté vers une ablation de l'hydatide. Pour les deux patientes, aucune complication postopératoire n'a été relevée. La torsion d'annexe est une urgence à ne pas méconnaître devant toute douleur pelvienne aigue chez la femme enceinte. Le traitement conservateur est actuellement le gold standard et une prise en charge appropriée est nécessaire pour éviter d'éventuelles complications maternelles et fœtales. PMID:28292076
2016-09-07
This synthetic-aperture radar (SAR) image was obtained by NASA's Cassini spacecraft on July 25, 2016, during its "T-121" pass over Titan's southern latitudes. The image shows an area nicknamed the "Xanadu annex" by members of the Cassini radar team, earlier in the mission. This area had not been imaged by until now, but measurements of its brightness temperature from Cassini's microwave radiometer were quite similar to that of the large region on Titan named Xanadu (see PIA20713), which lies just to the north. Cassini's radiometer is essentially a very sensitive thermometer, and brightness temperature is a measure of the intensity of microwave radiation received from a feature by the instrument. Radar team members predicted at the time that, if this area were ever imaged, it would be similar in appearance to Xanadu. That earlier hunch appears to have been borne out, as features in this scene bear a strong similarity to the mountainous terrains Cassini's radar has imaged in Xanadu. Xanadu -- and now perhaps its annex -- remains something of a mystery. First imaged in 1994 by the Hubble Space Telescope (just three years before Cassini's launch from Earth), Xanadu was the first surface feature to be recognized on Titan. Once thought to be a raised plateau, the region is now understood to be slightly tilted, but not higher than, the darker surrounding regions. It blocks the formation of sand dunes, which otherwise extend all the way around Titan at its equator. The area shown here is illuminated by the radar from the bottom at a 30-degree incidence angle. It measures about 155 by 310 miles (250 by 500 kilometers) and is centered at about 30 degrees south latitude, 60 degrees west longitude. http://photojournal.jpl.nasa.gov/catalog/PIA20712
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-30
...EPA is finalizing emission standards for new marine diesel engines with per-cylinder displacement at or above 30 liters (called Category 3 marine diesel engines) installed on U.S. vessels. These emission standards are equivalent to those adopted in the amendments to Annex VI to the International Convention for the Prevention of Pollution from Ships (MARPOL Annex VI). The emission standards apply in two stages--near-term standards for newly built engines will apply beginning in 2011; long-term standards requiring an 80 percent reduction in NOX emissions will begin in 2016. We are also finalizing a change to our diesel fuel program that will allow for the production and sale of 1,000 ppm sulfur fuel for use in Category 3 marine vessels. In addition, the new fuel requirements will generally forbid the production and sale of other fuels above 1,000 ppm sulfur for use in most U.S. waters, unless alternative devices, procedures, or compliance methods are used to achieve equivalent emissions reductions. We are adopting further provisions under the Act to Prevent Pollution from Ships, especially to apply the emission standards to engines covered by MARPOL Annex VI that are not covered by the Clean Air Act, and to require that these additional engines use the specified fuels (or equivalents). The final regulations also include technical amendments to our motor vehicle and nonroad engine regulations; many of these changes involve minor adjustments or corrections to our recently finalized rule for new nonroad spark-ignition engines, or adjustment to other regulatory provisions to align with this recent final rule.
Agricultural soil greenhouse gas emissions: a review of national inventory methods.
Lokupitiya, Erandathie; Paustian, Keith
2006-01-01
Parties to the United Nations Framework Convention on Climate Change (UNFCCC) are required to submit national greenhouse gas (GHG) inventories, together with information on methods used in estimating their emissions. Currently agricultural activities contribute a significant portion (approximately 20%) of global anthropogenic GHG emissions, and agricultural soils have been identified as one of the main GHG source categories within the agricultural sector. However, compared to many other GHG sources, inventory methods for soils are relatively more complex and have been implemented only to varying degrees among member countries. This review summarizes and evaluates the methods used by Annex 1 countries in estimating CO2 and N2O emissions in agricultural soils. While most countries utilize the Intergovernmental Panel on Climate Change (IPCC) default methodology, several Annex 1 countries are developing more advanced methods that are tailored for specific country circumstances. Based on the latest national inventory reporting, about 56% of the Annex 1 countries use IPCC Tier 1 methods, about 26% use Tier 2 methods, and about 18% do not estimate or report N2O emissions from agricultural soils. More than 65% of the countries do not report CO2 emissions from the cultivation of mineral soils, organic soils, or liming, and only a handful of countries have used country-specific, Tier 3 methods. Tier 3 methods usually involve process-based models and detailed, geographically specific activity data. Such methods can provide more robust, accurate estimates of emissions and removals but require greater diligence in documentation, transparency, and uncertainty assessment to ensure comparability between countries. Availability of detailed, spatially explicit activity data is a major constraint to implementing higher tiered methods in many countries.
Implementation of Releasing Time to Care - the productive ward.
Wilson, Gwyneth
2009-07-01
This paper describes the implementation of the NHS Institute for Innovation and Improvement Productive Ward - releasing time to care programme. It will discuss the benefits and key successes and provides advice for those wishing to implement the programme. In Lord Darzi's Next Stage Review, he advocates an ambitious vision of patient centred - clinician led, locally driven NHS. The Releasing Time to Care programme is a unique opportunity for everyone working within the NHS to improve effectiveness, safety and reliability of the services we provide. Whilst being situated within a National Health Service policy environment learning from this work can be translated nationally and internationally, as the principles underpin the provision of high quality care. Evaluation is currently in relation to each of the 15 modules rather than as the programme as a whole. It uses various methods including audit, observation, activity follow through, satisfaction surveys and process mapping. Each month data is colated for each of the 11 metrics which has shown a reduction in falls, drug administration errors and improvement in the recording of patient observations. One of the key issues is that an essential component for the success of the programme lies in the tangible support of the Trust Board/Board of Directors. Evidence shows that this programme improves patient satisfaction as it enables the provision of an increase in direct patient care by staff and subsequently improved clinical and safety outcomes. Ward Sister/Charge Nurse development includes Leadership, Project management and Lean Methodology techniques. The Releasing Time to Care programme is a key component of the Next Stage Review. It will create productive organisations by being a catalyst for the transformation of Trust services, enabling staff to spend more time caring for patients and users. This release in time will result in better outcomes and subsequent improvement with patient and staff satisfaction and experience of the NHS as well as a cultural change for the workforce. Releasing Time to Care, also known as the productive ward, offers a systematic way of delivering safe, high quality care to patients across healthcare settings. The Institute for Innovation and Improvement, have devised a programme of 15 modules based on 'lean' methodology. It has been widely piloted and in January 2008 was rolled out as a national initiative with 50 million pound pump priming money. Evidence shows that the programme can improve patient satisfaction as it enables the provision of an increase in direct patient care by staff and subsequent improved clinical and safety outcomes. The programme has to be implemented in a structured manner in order to assure its success and release the benefits. Core to this success is Board level commitment. Board members need to sign up to and understand the concepts of the programme and their role in supporting the ward staff. The organisation needs to understand the benefits that the programme will bring to the organisation as well as the challenges. The Board needs to understand that the programme is focussed on improving the quality of care for patients and not an opportunity to reduce costs.
Code of Federal Regulations, 2014 CFR
2014-01-01
... SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Introduction § 3300.4..., whose address is: 1405 Auditors Building, 201 14th Street, SW., Washington, DC 20250. ATP means the... Such Carriage (ATP), and the annexes and appendices thereto, done at Geneva, September 1, 1970, under...
Code of Federal Regulations, 2012 CFR
2012-01-01
... SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Introduction § 3300.4..., whose address is: 1405 Auditors Building, 201 14th Street, SW., Washington, DC 20250. ATP means the... Such Carriage (ATP), and the annexes and appendices thereto, done at Geneva, September 1, 1970, under...
Code of Federal Regulations, 2013 CFR
2013-01-01
... SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Introduction § 3300.4..., whose address is: 1405 Auditors Building, 201 14th Street, SW., Washington, DC 20250. ATP means the... Such Carriage (ATP), and the annexes and appendices thereto, done at Geneva, September 1, 1970, under...
Code of Federal Regulations, 2011 CFR
2011-01-01
... SUCH CARRIAGE (ATP); INSPECTION, TESTING, AND CERTIFICATION OF SPECIAL EQUIPMENT Introduction § 3300.4..., whose address is: 1405 Auditors Building, 201 14th Street, SW., Washington, DC 20250. ATP means the... Such Carriage (ATP), and the annexes and appendices thereto, done at Geneva, September 1, 1970, under...
Code of Federal Regulations, 2013 CFR
2013-04-01
... WEAPONS CONVENTION AND THE CHEMICAL WEAPONS CONVENTION IMPLEMENTATION ACT OF 1998 ON THE TAKING OF SAMPLES... Office of Export Administration and the Office of Export Enforcement. Chemical Weapons Convention (CWC or... Chemical Weapons and on Their Destruction, and its annexes opened for signature on January 13, 1993, and...
Code of Federal Regulations, 2014 CFR
2014-04-01
... WEAPONS CONVENTION AND THE CHEMICAL WEAPONS CONVENTION IMPLEMENTATION ACT OF 1998 ON THE TAKING OF SAMPLES... Office of Export Administration and the Office of Export Enforcement. Chemical Weapons Convention (CWC or... Chemical Weapons and on Their Destruction, and its annexes opened for signature on January 13, 1993, and...
1987 Population Trends for Washington State.
ERIC Educational Resources Information Center
Washington State Office of Financial Management, Olympia.
This statistical profile provides current demographic data for Washington State and is also broken down by counties, incorporated cities, and towns. Fifteen tables show population figures; components of population change; housing units by structure type; annexations, incorporations and municipal boundary changes; growth of households; estimates of…
Interior view of west end entry showing entry hallway and ...
Interior view of west end entry showing entry hallway and double-door frame, view facing south - U.S. Naval Base, Pearl Harbor, Administration Annex, Near Russell Avenue (previously Avenue E), between of Facility Nos. 1C & 1E , Pearl City, Honolulu County, HI
Contextual view of Fyffe Avenue and Boone Drive. Dispensary (Naval ...
Contextual view of Fyffe Avenue and Boone Drive. Dispensary (Naval Medical Center Oakland and Dental Clinic San Francisco Branch Clinics, Building no. 417) is shown at left. Camera facing northwest. - Naval Supply Annex Stockton, Rough & Ready Island, Stockton, San Joaquin County, CA
Contextual view of Fyffe Avenue and Boone Drive. Dispensary (Naval ...
Contextual view of Fyffe Avenue and Boone Drive. Dispensary (Naval Medical Center Oakland and Dental Clinic San Francisco Branch Clinics, building no. 417) is shown at the center. Camera facing northeast. - Naval Supply Annex Stockton, Rough & Ready Island, Stockton, San Joaquin County, CA
U.S. ARMY QUARTERMASTER CORPS FORM NO. 173A (1916); INITIAL PROPERTY ...
U.S. ARMY QUARTERMASTER CORPS FORM NO. 173A (1916); INITIAL PROPERTY RECORD CARD FOR BUILDING NO. 121 (NOW 30023) (ON FILE AT THE FORT HUACHUCA HISTORICAL MUSEUM ANNEX) - Fort Huachuca, Cavalry Stable, Clarkson Road, Sierra Vista, Cochise County, AZ
Aeronautical Information Publication (AIP) United States of America (14th ed : 1997)
DOT National Transportation Integrated Search
1997-01-30
The AIP is prepared in accordance with the Standards and Recommended Practices : (SARPS) of Annex 15 to the Convention on International Civil Aviation and the : Aeronautical Information Services Manual (ICAO Doc 8126). The AIP is made up : of three P...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-16
... placement of sidelights above the hull of the vessel; Annex I, paragraph 2(i)(iii) pertaining to the... height of aft light Vessel Number Lights arc of of visibility; arc of board of forward of above hull in...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-30
...(a)(i), pertaining to the height placement of the masthead light above the hull; Annex I, paragraph 2...) visibility; rule 21(b) visibility; ship's sides stern in above hull in light to forward light rule 21(c) in...
14 CFR 171.27 - Performance requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
...” (Annex 10 to the Convention on International Civil Aviation), except that identification by on-off keying... electronic engineering practices for the desired service. (c) Ground inspection consists of an examination of the design features of the equipment to determine (based on recognized and accepted good engineering...
14 CFR 34.89 - Compliance with smoke emission standards.
Code of Federal Regulations, 2011 CFR
2011-01-01
... TRANSPORTATION AIRCRAFT FUEL VENTING AND EXHAUST EMISSION REQUIREMENTS FOR TURBINE ENGINE POWERED AIRPLANES Test Procedures for Engine Smoke Emissions (Aircraft Gas Turbine Engines) § 34.89 Compliance with smoke emission... in Appendix 6 to ICAO Annex 16, Environmental Protection, Volume II, Aircraft Engine Emissions...
14 CFR 34.89 - Compliance with smoke emission standards.
Code of Federal Regulations, 2010 CFR
2010-01-01
... TRANSPORTATION AIRCRAFT FUEL VENTING AND EXHAUST EMISSION REQUIREMENTS FOR TURBINE ENGINE POWERED AIRPLANES Test Procedures for Engine Smoke Emissions (Aircraft Gas Turbine Engines) § 34.89 Compliance with smoke emission... in Appendix 6 to ICAO Annex 16, Environmental Protection, Volume II, Aircraft Engine Emissions...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 31 Money and Finance:Treasury 2 2013-07-01 2013-07-01 false Applicability. 407.2 Section 407.2 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) SECRET SERVICE, DEPARTMENT OF THE TREASURY REGULATIONS GOVERNING CONDUCT IN THE TREASURY BUILDING AND THE TREASURY ANNEX...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 31 Money and Finance:Treasury 2 2012-07-01 2012-07-01 false Applicability. 407.2 Section 407.2 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) SECRET SERVICE, DEPARTMENT OF THE TREASURY REGULATIONS GOVERNING CONDUCT IN THE TREASURY BUILDING AND THE TREASURY ANNEX...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 31 Money and Finance:Treasury 2 2011-07-01 2011-07-01 false Applicability. 407.2 Section 407.2 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) SECRET SERVICE, DEPARTMENT OF THE TREASURY REGULATIONS GOVERNING CONDUCT IN THE TREASURY BUILDING AND THE TREASURY ANNEX...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Applicability. 407.2 Section 407.2 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) SECRET SERVICE, DEPARTMENT OF THE TREASURY REGULATIONS GOVERNING CONDUCT IN THE TREASURY BUILDING AND THE TREASURY ANNEX...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 31 Money and Finance: Treasury 2 2014-07-01 2014-07-01 false Applicability. 407.2 Section 407.2 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) SECRET SERVICE, DEPARTMENT OF THE TREASURY REGULATIONS GOVERNING CONDUCT IN THE TREASURY BUILDING AND THE TREASURY ANNEX...
The response of pile-guided floats subjected to dynamic loading : volume II annex.
DOT National Transportation Integrated Search
2014-08-01
Pile-Guided floats can be a desirable alternative to stationary berthing structures. Both floats and guide piles are subjected to dynamic : forces such as wind generated waves and impacts from vessels. This project developed a rational basis for esti...
A Kingdom Lost: The U.S. Annexation of Hawaii
2001-04-10
location in the central Pacific. In January of 1893, Queen Liliuokalani announced her intentions to promulgate a new constitution that would restore...the next five years, Queen Liliuokalani would unsuccessfully attempt to reestablish the Hawaiian monarchy. On 7 July 1898, President McKinley signed
Code of Federal Regulations, 2010 CFR
2010-10-01
... permanent steel bulkheads. CSC safety approval plate means the safety approval plate specified in Annex I of... tank tops, decks, bulkheads, frames, plating, or ladders, or used for filling voids or fitting around... cargo on board a vessel. Portable magazine means a strong, closed, prefabricated, steel or wooden...
76 FR 44053 - Post Office Closing
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-22
... POSTAL REGULATORY COMMISSION [Docket No. A2011-20; Order No. 760] Post Office Closing AGENCY: Postal Regulatory Commission. ACTION: Notice. SUMMARY: This document informs the public that an appeal of the closing of the La Mesa Annex, CA Station has been filed. It identifies preliminary steps and...
ERIC Educational Resources Information Center
Piele, Philip K.
Numerous cases in this year's chapter dealt with the same topics of previous years--contracts and bids for building construction, and detachment and annexation of a portion of a school district. The courts continued to attribute board discretionary authority to school boards in school property matters. Intergovernmental disputes over ownership or…
View of approach span and movable span, looking southeast from ...
View of approach span and movable span, looking southeast from navy land. Note that navigational channel exists only on north side of movable span. - Naval Supply Annex Stockton, Daggett Road Bridge, Daggett Road traversing Burns Cut Off, Stockton, San Joaquin County, CA
Detail of "pin" or large bolt used to assemble the ...
Detail of "pin" or large bolt used to assemble the truss pieces. This "pin" is on pony truss; similar pins were used on movable span. - Naval Supply Annex Stockton, Daggett Road Bridge, Daggett Road traversing Burns Cut Off, Stockton, San Joaquin County, CA
Lake Erie phosphorus loading and Cladophora updates
The presentation will focus on updates or progress being made on each Phosphorus Loadings and Cladophora for Lake Erie. The format will give a brief summary of data, findings, and results that were used by the Great Lakes Water Quality Agreement (GLWQA) Annex 4 Nutrients Modeli...
2011-06-01
Venue Site WACC - Whistler Area Command Centre OTHER GPPAG - Government Partners Public Affairs Group 18 ANNEX B. Interview questions...Vancouver Vancouver Richmond WACC Decision Authority Link Information Sharing Link DOC’s 2010 Provincial Games Secretariat GPPAG CCG
Torsion d'annexe en cours de grossesse: à propos d'un cas à l'Hôpital Central de Yaoundé, Cameroun
Fouedjio, Jeanne Hortence; Fouogue, Jovanny Tsuala; Fouelifack, Florent Ymele; Nangue, Charlette; Sando, Zacharie; Enow Mbu, Robinson
2014-01-01
Les kystes ovariens sont dans la majorité des cas asymptomatiques et peuvent être de découverte fortuite lors d'une échographie. Ils ne deviennent symptomatiques que lorsque survient une complication. Nous présentons un cas de torsion d'annexe gauche diagnostiqué à 8 semaines et 4 jours de grossesse. Nous avons réalisé une annexectomie Suivie de l'administration de progestérone retard à la dose 500 mg par jour. L'évolution a été marquée par la survenue d'un avortement au cinquième jour post opératoire. L'analyse anatomopathologique de la masse chirurgicale a conclu à une apoplexie ovarienne. L'ablation chirurgicale du corps jaune au premier trimestre de la grossesse pose le problème du maintien de celle - ci et devrait être présente à l'esprit des praticiens avant toute chirurgie pelvienne pendant cette période. PMID:24932350
WHO Expert Committee on Specifications for Pharmaceutical Preparations.
2003-01-01
This report presents the recommendations of an international group of experts convened by the World Health Organization to consider matters concerning the quality assurance of pharmaceuticals and specifications for drug substances and dosage forms. Of particular relevance to drug regulatory authorities and pharmaceutical manufacturers, the report discusses activities related to the development of The International Pharmacopoeia and basic tests for pharmaceutical substances and dosage forms, as well as quality control of reference materials, good manufacturing practices (GMP), stability studies, inspection, hazard analysis, procurement, storage and other aspects of quality assurance of pharmaceuticals, and regulatory issues. The report is complemented by a number of annexes, including recommendations on the risk of transmitting animal spongiform encephalopathy agents via medicinal products, guidelines on GMP for pharmaceutical products, a model certificate for GMP and guidance on a GMP inspection report. The final annexes provide guidance on the application of Hazard Analysis and Critical Control Point (HACCP) method to pharmaceuticals, good storage practices and a procedure for assessing acceptability of pharmaceutical products for purchase by United Nations agencies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Venezuela
This report contains the results of efforts under the six tasks of the Tenth Amendment anti Extension of Annex IV, Enhanced Oil Recovery Thermal Processes of the Venezuela/USA Energy Agreement. This report is presented in sections (for each of the six Tasks) and each section contains one or more reports that were prepared to describe the results of the effort under each of the Tasks. A statement of each Task, taken from the Agreement Between Project Managers, is presented on the first page of each section. The Tasks are numbered 68 through 73. The first through tenth report on researchmore » performed under Annex IV Venezuela MEM/USA-DOE Fossil Energy Report Number IV-1, IV-2, IV-3, IV-4, IV-5, IV-6, IV-7, IV-8, IV-9, IV-10 contain the results of the first 67 Tasks. These reports are dated April 1983, August 1984, March 1986, July 1987, November 1988, December 1989, October 1991, February 1993, March 1995, and December 1997, respectively.« less
Methods of milk expression for lactating women.
Becker, Genevieve E; Smith, Hazel A; Cooney, Fionnuala
2016-09-29
Breastfeeding is important, however not all infants can feed at the breast and methods of expressing milk need evaluation. To assess acceptability, effectiveness, safety, effect on milk composition, contamination and costs of methods of milk expression. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (21 March 2016), handsearched relevant journals and conference proceedings, and contacted experts in the field to seek additional published or unpublished studies. We also examined reference lists of all relevant retrieved papers. Randomised and quasi-randomised trials comparing methods at any time after birth. Three review authors independently assessed trials for inclusion and risk of bias, extracted data and checked them for accuracy. This updated review includes 41 trials involving 2293 participants, with 22 trials involving 1339 participants contributing data for analysis. Twenty-six of the trials referred to mothers of infants in neonatal units (n = 1547) and 14 to mothers of healthy infants at home (n = 730), with one trial containing mothers of both neonatal and healthy older infants (n = 16). Eleven trials compared one or more types of pump versus hand expression and 14 studies compared one type of pump versus another type of pump, with three of these studies comparing both hand expression and pump types. Twenty studies compared a specific protocol or adjunct behaviour including sequential versus simultaneous pumping protocols, pumping frequency, provision of an education and support intervention, relaxation, breast massage, combining hand expression with pumping and a breast cleansing protocol.Due to heterogeneity in participants, interventions, and outcomes measured or reported, we were unable to pool findings for most of the specified outcomes. It was not possible therefore to produce a 'Summary of findings' table in this update. Most of the included results were derived from single studies. Trials took place in 14 countries under a variety of circumstances and were published from 1982 to 2015. Sixteen of the 30 trials that evaluated pumps or products had support from the manufacturers. The risk of bias of the included studies was variable. Primary outcomesOnly one of the 17 studies examining maternal satisfaction/acceptability with the method or adjunct behaviour provided data suitable for analysis. In this study, self-efficacy was assessed by asking mothers if they agreed or disagreed with the following statement: 'I don't want anyone to see me (hand expressing/pumping)'. The study found that mothers who were using the electric pump were more likely to agree with the statement compared to mothers hand expressing, (mean difference (MD) 0.70, 95% confidence interval (CI) 0.15 to 1.25; P = 0.01, participants = 68). Mothers who were hand expressing reported that the instructions for expression were clearer compared to the electric pump, (MD -0.40, 95% CI -0.75 to -0.05; P = 0.02, participants = 68). Descriptive reporting of satisfaction in the other studies varied in the measures used, did not indicate a clear preference for one pump type, although there was satisfaction with some relaxation and support interventions.We found no clinically significant differences between methods related to contamination of the milk that compared any type of pump to hand expression (risk ratio (RR) 1.13, 95% CI 0.79 to 1.61; P = 0.51, participants = 28), manual pump compared to hand expression, (MD 0.20, 95% CI -0.18 to 0.58; P = 0.30, participants = 142) a large electric pump compared to hand expression (MD 0.10, 95% CI -0.29 to 0.49; P = 0.61, participants = 123), or a large electric pump compared to a manual pump (MD -0.10, 95% CI -0.46 to 0.26; P = 0.59, participants = 141).The level of maternal breast or nipple pain or damage was similar in comparisons of a large electric pump to hand expression (MD 0.02, 95% CI -0.67 to 0.71; P = 0.96, participants = 68). A study comparing a manual and large electric pump, reported sore nipples in 7% for both groups and engorgement in 4% using a manual pump versus 6% using an electric pump; and in one study no nipple damage was reported in the hand-expression group, and one case of nipple damage in each of the manual pump and the large electric pump groups.One study examined adverse effects on infants, however as the infants did not all receive their mothers' expressed milk, we have not included the results. Secondary outcomesThe quantity of expressed milk obtained was increased, in some studies by a clinically significant amount, in interventions involving relaxation, music, warmth, massage, initiation of pumping, increased frequency of pumping and suitable breast shield size. Support programmes and simultaneous compared to sequential pumping did not show a difference in milk obtained. No pump consistently increased the milk volume obtained significantly.In relation to nutrient quality, hand expression or a large electric pump were found to provide higher protein than a manual pump, and hand expression provided higher sodium and lower potassium compared to a large electric pump or a manual pump. Fat content was higher with breast massage when pumping; no evidence of difference was found for energy content between methods.No consistent effect was found related to prolactin change or effect on oxytocin release with pump type or method. Economic aspects were not reported. The most suitable method for milk expression may depend on the time since birth, purpose of expression and the individual mother and infant. Low-cost interventions including initiation of milk expression sooner after birth when not feeding at the breast, relaxation, massage, warming the breasts, hand expression and lower cost pumps may be as effective, or more effective, than large electric pumps for some outcomes. Variation in nutrient content across methods may be relevant to some infants. Small sample sizes, large standard deviations, and the diversity of the interventions argue caution in applying these results beyond the specific method tested in the specific settings. Independently funded research is needed for more trials on hand expression, relaxation and other techniques that do not have a commercial potential.
33 CFR 151.32 - Special areas for the purpose of Annex II.
Code of Federal Regulations, 2013 CFR
2013-07-01
... SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance Pollution...
38 CFR 36.4361 - Acceptable ownership arrangements and documentation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... owners, lenders and the holders, insurers and guarantors of the first mortgage on any unit, current... available to prospective purchasers current copies of the declaration, bylaws, other rules governing the... amendments which annex additional phases to the condominium regime in accordance with a general plan of...
33 CFR 87.5 - Supplemental signals.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Supplemental signals. 87.5... NAVIGATION RULES ANNEX IV: DISTRESS SIGNALS § 87.5 Supplemental signals. Attention is drawn to the relevant sections of the International Code of Signals, the Merchant Ship Search and Rescue Manual, the...
33 CFR 87.5 - Supplemental signals.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Supplemental signals. 87.5... NAVIGATION RULES ANNEX IV: DISTRESS SIGNALS § 87.5 Supplemental signals. Attention is drawn to the relevant sections of the International Code of Signals, the Merchant Ship Search and Rescue Manual, the...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Construction. 86.23 Section 86.23 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY INLAND NAVIGATION RULES ANNEX III: TECHNICAL DETAILS OF SOUND SIGNAL APPLIANCES Bell or Gong § 86.23 Construction. Bells and gongs...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Construction. 86.23 Section 86.23 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY INLAND NAVIGATION RULES ANNEX III: TECHNICAL DETAILS OF SOUND SIGNAL APPLIANCES Bell or Gong § 86.23 Construction. Bells and gongs...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Construction. 86.23 Section 86.23 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY INLAND NAVIGATION RULES ANNEX III: TECHNICAL DETAILS OF SOUND SIGNAL APPLIANCES Bell or Gong § 86.23 Construction. Bells and gongs...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 1 2013-07-01 2013-07-01 false Construction. 86.23 Section 86.23 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY INLAND NAVIGATION RULES ANNEX III: TECHNICAL DETAILS OF SOUND SIGNAL APPLIANCES Bell or Gong § 86.23 Construction. Bells and gongs...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 1 2014-07-01 2014-07-01 false Construction. 86.23 Section 86.23 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY INLAND NAVIGATION RULES ANNEX III: TECHNICAL DETAILS OF SOUND SIGNAL APPLIANCES Bell or Gong § 86.23 Construction. Bells and gongs...
SLS Intertank Test Article, ITA, is attached to crosshead of loa
2018-04-04
SLS Intertank Test Article, ITA, is attached to crosshead of load test Annex, Bldg. 4619, and removed from bed of KMAG transporter. Rob Ziegler, L, and Roger Myrick, R, of Aerie Aerospace attach load lines to Aft Load Ring of Intertank Test Articlle
The SLS Stages Intertank Structural Test Assembly (STA) arrives at MSFC
2018-03-06
The SLS Stages Intertank Structural Test Assembly (STA) is rolling off the NASA Pegasus Barge at the MSFC Dock enroute to the MSFC 4619 Load Test Annex test facility for qualification testing. STA hardware completely free of barge and flanked by tug boats.
SLS Intertank Test Article, ITA, is attached to crosshead of loa
2018-04-04
SLS Intertank Test Article, ITA, is attached to crosshead of load test Annex, Bldg. 4619, and removed from bed of KMAG transporter. Rob Ziegler, (L), and Roger Myrick (R), of Aerie Aerospace attach load lines to Aft Load Ring of Intertank Test Article.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-08
... placement of the forward anchor light above the hull; Annex I, paragraph 3(b), pertaining to the location of...; visibility; ship's sides stern in hull in forward light in rule 21(a) rule 21(b) rule 21(c) in meters meters...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-17
... Marine safety, Navigation (water), and Vessels. 0 Accordingly, 32 CFR Part 706 is corrected pursuant to...; rule 21(b) rule 21(c) sides in stern in in meters; in meters 2(K) annex 1 rule 21(a) meters 3(b) meters...
Questionnaire Construction Manual. Annex: Literature Survey and Bibliography.
ERIC Educational Resources Information Center
Dyer, Robert; And Others
A literature review and bibliography on questionnaire construction are presented. The broad definition of questionnaire includes scales, structured interview forms, survey forms, and similar paper and pencil instruments used to elicit responses and collect information. A comprehensive literature search of journal articles, books, and reports in…
Code of Federal Regulations, 2010 CFR
2010-07-01
... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Nuisances. 407.6 Section 407.6 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) SECRET SERVICE, DEPARTMENT OF THE TREASURY REGULATIONS GOVERNING CONDUCT IN THE TREASURY BUILDING AND THE TREASURY ANNEX § 407.6...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 31 Money and Finance:Treasury 2 2013-07-01 2013-07-01 false Gambling. 407.7 Section 407.7 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) SECRET SERVICE, DEPARTMENT OF THE TREASURY REGULATIONS GOVERNING CONDUCT IN THE TREASURY BUILDING AND THE TREASURY ANNEX § 407.7...
31 CFR 407.3 - Recording presence.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Recording presence. 407.3 Section 407.3 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) SECRET SERVICE, DEPARTMENT OF THE TREASURY REGULATIONS GOVERNING CONDUCT IN THE TREASURY BUILDING AND THE TREASURY ANNEX...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 31 Money and Finance:Treasury 2 2011-07-01 2011-07-01 false Nuisances. 407.6 Section 407.6 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) SECRET SERVICE, DEPARTMENT OF THE TREASURY REGULATIONS GOVERNING CONDUCT IN THE TREASURY BUILDING AND THE TREASURY ANNEX § 407.6...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 31 Money and Finance:Treasury 2 2012-07-01 2012-07-01 false Nuisances. 407.6 Section 407.6 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) SECRET SERVICE, DEPARTMENT OF THE TREASURY REGULATIONS GOVERNING CONDUCT IN THE TREASURY BUILDING AND THE TREASURY ANNEX § 407.6...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Gambling. 407.7 Section 407.7 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) SECRET SERVICE, DEPARTMENT OF THE TREASURY REGULATIONS GOVERNING CONDUCT IN THE TREASURY BUILDING AND THE TREASURY ANNEX § 407.7...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 31 Money and Finance:Treasury 2 2012-07-01 2012-07-01 false Gambling. 407.7 Section 407.7 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) SECRET SERVICE, DEPARTMENT OF THE TREASURY REGULATIONS GOVERNING CONDUCT IN THE TREASURY BUILDING AND THE TREASURY ANNEX § 407.7...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 31 Money and Finance: Treasury 2 2014-07-01 2014-07-01 false Gambling. 407.7 Section 407.7 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) SECRET SERVICE, DEPARTMENT OF THE TREASURY REGULATIONS GOVERNING CONDUCT IN THE TREASURY BUILDING AND THE TREASURY ANNEX § 407.7...
31 CFR 407.3 - Recording presence.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 31 Money and Finance:Treasury 2 2013-07-01 2013-07-01 false Recording presence. 407.3 Section 407.3 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) SECRET SERVICE, DEPARTMENT OF THE TREASURY REGULATIONS GOVERNING CONDUCT IN THE TREASURY BUILDING AND THE TREASURY ANNEX...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 31 Money and Finance: Treasury 2 2014-07-01 2014-07-01 false Nuisances. 407.6 Section 407.6 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) SECRET SERVICE, DEPARTMENT OF THE TREASURY REGULATIONS GOVERNING CONDUCT IN THE TREASURY BUILDING AND THE TREASURY ANNEX § 407.6...
31 CFR 407.3 - Recording presence.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 31 Money and Finance:Treasury 2 2011-07-01 2011-07-01 false Recording presence. 407.3 Section 407.3 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) SECRET SERVICE, DEPARTMENT OF THE TREASURY REGULATIONS GOVERNING CONDUCT IN THE TREASURY BUILDING AND THE TREASURY ANNEX...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 31 Money and Finance:Treasury 2 2013-07-01 2013-07-01 false Nuisances. 407.6 Section 407.6 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) SECRET SERVICE, DEPARTMENT OF THE TREASURY REGULATIONS GOVERNING CONDUCT IN THE TREASURY BUILDING AND THE TREASURY ANNEX § 407.6...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 31 Money and Finance:Treasury 2 2011-07-01 2011-07-01 false Gambling. 407.7 Section 407.7 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) SECRET SERVICE, DEPARTMENT OF THE TREASURY REGULATIONS GOVERNING CONDUCT IN THE TREASURY BUILDING AND THE TREASURY ANNEX § 407.7...
31 CFR 407.3 - Recording presence.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 31 Money and Finance: Treasury 2 2014-07-01 2014-07-01 false Recording presence. 407.3 Section 407.3 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) SECRET SERVICE, DEPARTMENT OF THE TREASURY REGULATIONS GOVERNING CONDUCT IN THE TREASURY BUILDING AND THE TREASURY ANNEX...
31 CFR 407.3 - Recording presence.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 31 Money and Finance:Treasury 2 2012-07-01 2012-07-01 false Recording presence. 407.3 Section 407.3 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) SECRET SERVICE, DEPARTMENT OF THE TREASURY REGULATIONS GOVERNING CONDUCT IN THE TREASURY BUILDING AND THE TREASURY ANNEX...
13.1 Foot Diameter Fluted-Core Sandwich Composite Test Article
2013-09-26
White light shape and measurement of a 13.1 Foot diameter fluted-core sandwich composite test article designed by LaRC and fabricated by Boeing Under Space Act Agreement SAA1-737, Annex 14. to be tested in LaRC's combined Loads Testing System (COLTS).
13.1 Foot Diameter Fluted-Core Sandwich Composite Test Article
2013-09-25
White light shape and measurement of a 13.1 Foot diameter fluted-core sandwich composite test article designed by LaRC and fabricated by Boeing Under Space Act Agreement SAA1-737, Annex 14. to be tested in LaRC's combined Loads Testing System (COLTS).
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Audit. 225.872-6 Section...-6 Audit. (a) Memoranda of understanding with some qualifying countries contain annexes that provide for reciprocal “no-cost” audits of contracts and subcontracts (pre- and post-award). (b) To determine...
Forecasting Water Use on Fixed Army Installations within the Contiguous United States.
1984-06-22
Laundromats Car wash L Cafeterias/restaurants Main clubs and annexes Industrial Public/Institutional Vehicle and aircraft wash facilities Offices and...residents, who may prefer to use laundromats located elsewhere. Training Classrooms and other special buildings in which instruction is given make up this
33 CFR 151.32 - Special areas for the purpose of Annex II.
Code of Federal Regulations, 2012 CFR
2012-07-01
... SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance Pollution...
33 CFR 151.32 - Special areas for the purpose of Annex II.
Code of Federal Regulations, 2014 CFR
2014-07-01
... SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance Pollution...
33 CFR 151.32 - Special areas for the purpose of Annex II.
Code of Federal Regulations, 2011 CFR
2011-07-01
... SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance Pollution...
40 CFR 300.210 - Federal contingency plans.
Code of Federal Regulations, 2014 CFR
2014-07-01
... response plans of state, local, and non-federal entities, and especially with Title III local emergency... between this annex and non-federal response plans (including those of vessels, facilities, and pipelines... 40 Protection of Environment 28 2014-07-01 2014-07-01 false Federal contingency plans. 300.210...
40 CFR 300.210 - Federal contingency plans.
Code of Federal Regulations, 2013 CFR
2013-07-01
... response plans of state, local, and non-federal entities, and especially with Title III local emergency... between this annex and non-federal response plans (including those of vessels, facilities, and pipelines... 40 Protection of Environment 29 2013-07-01 2013-07-01 false Federal contingency plans. 300.210...
40 CFR 300.210 - Federal contingency plans.
Code of Federal Regulations, 2011 CFR
2011-07-01
... response plans of state, local, and non-federal entities, and especially with Title III local emergency... between this annex and non-federal response plans (including those of vessels, facilities, and pipelines... 40 Protection of Environment 28 2011-07-01 2011-07-01 false Federal contingency plans. 300.210...
40 CFR 300.210 - Federal contingency plans.
Code of Federal Regulations, 2012 CFR
2012-07-01
... response plans of state, local, and non-federal entities, and especially with Title III local emergency... between this annex and non-federal response plans (including those of vessels, facilities, and pipelines... 40 Protection of Environment 29 2012-07-01 2012-07-01 false Federal contingency plans. 300.210...
33 CFR 151.13 - Special areas for Annex I of MARPOL 73/78.
Code of Federal Regulations, 2010 CFR
2010-07-01
... area, the Gulf of Aden, and the Antarctic area, the North West European waters, and Oman area of the... § 151.13 for the Red Sea area, Gulfs area, Gulf of Aden area, the Oman area of the Arabian Sea, and the...
Code of Federal Regulations, 2011 CFR
2011-10-01
... Management of Highly Migratory Fish Stocks in the Western and Central Pacific Ocean, with Annexes (WCPF... Conference on Highly Migratory Fish Stocks in the Western and Central Pacific Ocean, the terms used in this... information. Commercial, with respect to commercial fishing, means fishing in which the fish harvested, either...
Code of Federal Regulations, 2010 CFR
2010-10-01
... Management of Highly Migratory Fish Stocks in the Western and Central Pacific Ocean, with Annexes (WCPF... Conference on Highly Migratory Fish Stocks in the Western and Central Pacific Ocean, the terms used in this... information. Commercial, with respect to commercial fishing, means fishing in which the fish harvested, either...
Detail of west end of movable span. Shows lattice beams. ...
Detail of west end of movable span. Shows lattice beams. Latticed portal. Adjustable tension members connecting top chords, and metal floor beams looking south from navy land. - Naval Supply Annex Stockton, Daggett Road Bridge, Daggett Road traversing Burns Cut Off, Stockton, San Joaquin County, CA
View of pony truss approach span, showing metal caissons and ...
View of pony truss approach span, showing metal caissons and deck system, including metal floor beams and timber stringers. The same decking system was used on movable span. Looking north from civilian land. - Naval Supply Annex Stockton, Rough & Ready Island, Stockton, San Joaquin County, CA
33 CFR 87.5 - Supplemental signals.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 1 2014-07-01 2014-07-01 false Supplemental signals. 87.5... NAVIGATION RULES ANNEX IV: DISTRESS SIGNALS § 87.5 Supplemental signals. Attention is drawn to the relevant sections of the International Code of Signals, the Merchant Ship Search and Rescue Manual, the...
33 CFR 87.5 - Supplemental signals.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 1 2013-07-01 2013-07-01 false Supplemental signals. 87.5... NAVIGATION RULES ANNEX IV: DISTRESS SIGNALS § 87.5 Supplemental signals. Attention is drawn to the relevant sections of the International Code of Signals, the Merchant Ship Search and Rescue Manual, the...
33 CFR 87.5 - Supplemental signals.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Supplemental signals. 87.5... NAVIGATION RULES ANNEX IV: DISTRESS SIGNALS § 87.5 Supplemental signals. Attention is drawn to the relevant sections of the International Code of Signals, the Merchant Ship Search and Rescue Manual, the...
33 CFR 151.32 - Special areas for the purpose of Annex II.
Code of Federal Regulations, 2010 CFR
2010-07-01
... SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance Pollution...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sofrata, H.; Khoshaim, B.; Megahed, M.
1980-12-01
In this paper a computer package for the design and optimization of the simple Li-Br absorption air conditioning system, operated by solar energy, is developed in order to study its performance. This was necessary, as a first step, before carrying out any computations regarding the dual system (1-3). The computer package has the facilities of examining any parameter which may control the system; namely generator, evaporator, condenser, absorber temperatures and pumping factor. The output may be tabulated and also fed to the graph plotter. The flow chart of the programme is explained in an easy way and a typical examplemore » is included.« less
Status of HiLASE project: High average power pulsed DPSSL systems for research and industry
NASA Astrophysics Data System (ADS)
Mocek, T.; Divoky, M.; Smrz, M.; Sawicka, M.; Chyla, M.; Sikocinski, P.; Vohnikova, H.; Severova, P.; Lucianetti, A.; Novak, J.; Rus, B.
2013-11-01
We introduce the Czech national R&D project HiLASE which focuses on strategic development of advanced high-repetition rate, diode pumped solid state laser (DPSSL) systems that may find use in research, high-tech industry and in the future European large-scale facilities such as HiPER and ELI. Within HiLASE we explore two major concepts: thin-disk and cryogenically cooled multislab amplifiers capable of delivering average output powers above 1 kW level in picosecond-to-nanosecond pulsed regime. In particular, we have started a programme of technology development to demonstrate the scalability of multislab concept up to the kJ level at repetition rate of 1-10 Hz.
System for energy harvesting and/or generation, storage, and delivery
NASA Technical Reports Server (NTRS)
DeGreeff, Jenniffer Leigh (Inventor); Trainor, John T. (Inventor); Fleig, Patrick Franz (Inventor); Lakeman, Charles D. E. (Inventor)
2011-01-01
A device and method for harvesting, generating, storing, and delivering energy to a load, particularly for remote or inaccessible applications. The device preferably comprises one or more energy sources, at least one supercapacitor, at least one rechargeable battery, and a controller. The charging of the energy storage devices and the delivery of power to the load is preferably dynamically varied to maximize efficiency. A low power consumption charge pump circuit is preferably employed to collect power from low power energy sources while also enabling the delivery of higher voltage power to the load. The charging voltage is preferably programmable, enabling one device to be used for a wide range of specific applications.
System for energy harvesting and/or generation, storage, and delivery
NASA Technical Reports Server (NTRS)
DeGreeff, Jenniffer Leigh (Inventor); Trainor, John T. (Inventor); Fleig, Patrick Franz (Inventor); Lakeman, Charles D. E. (Inventor)
2010-01-01
A device and method for harvesting, generating, storing, and delivering energy to a load, particularly for remote or inaccessible applications. The device preferably comprises one or more energy sources, at least one supercapacitor, at least one rechargeable battery, and a controller. The charging of the energy storage devices and the delivery of power to the load is preferably dynamically varied to maximize efficiency. A low power consumption charge pump circuit is preferably employed to collect power from low power energy sources while also enabling the delivery of higher voltage power to the load. The charging voltage is preferably programmable, enabling one device to be used for a wide range of specific applications.
Tomography and Purification of the Temporal-Mode Structure of Quantum Light
NASA Astrophysics Data System (ADS)
Ansari, Vahid; Donohue, John M.; Allgaier, Markus; Sansoni, Linda; Brecht, Benjamin; Roslund, Jonathan; Treps, Nicolas; Harder, Georg; Silberhorn, Christine
2018-05-01
High-dimensional quantum information processing promises capabilities beyond the current state of the art, but addressing individual information-carrying modes presents a significant experimental challenge. Here we demonstrate effective high-dimensional operations in the time-frequency domain of nonclassical light. We generate heralded photons with tailored temporal-mode structures through the pulse shaping of a broadband parametric down-conversion pump. We then implement a quantum pulse gate, enabled by dispersion-engineered sum-frequency generation, to project onto programmable temporal modes, reconstructing the quantum state in seven dimensions. We also manipulate the time-frequency structure by selectively removing temporal modes, explicitly demonstrating the effectiveness of engineered nonlinear processes for the mode-selective manipulation of quantum states.
Raybould, J N; Barro, T; Sawadogo, R; Mordzifa, F
1982-06-01
Laboratory rearing of Simulium damnosum complex species enables female adults to be indirectly identified from their larval progeny. A simple, readily transportable rearing apparatus was developed for investigations by the Onchocerciasis Control programme by using unbreakable, easily packed and reassembled parts and by feeding the larvae at least partly with living green algae (Chlorophyceae) cultured in the laboratory. Although the larvae are sensitive to excess nitrogen compounds, the use of algae and a large volume of water obviated the need for a separate purification system in which water was circulated by an A/C electrical centrifugal pump between a container and an inclined trough in which most of the larvae developed. The rate of development was rapid giving rise to full size larvae (suitable for cytotaxonomic determination), pupae and adults. The adults were attracted into a collecting device by light. Developments to protect the larvae during electrical power failures included a slow-drying wooden rearing trough and an automatic switch to an alternative D/C power supply and pump. This technique has been in general use in O.C.P. laboratories in Benin, Ghana, Ivory Coast and Upper Volta and many thousands of larvae have been reared.