Sample records for punctures

  1. Cutting performance orthogonal test of single plane puncture biopsy needle based on puncture force

    NASA Astrophysics Data System (ADS)

    Xu, Yingqiang; Zhang, Qinhe; Liu, Guowei

    2017-04-01

    Needle biopsy is a method to extract the cells from the patient's body with a needle for tissue pathological examination. Many factors affect the cutting process of soft tissue, including the geometry of the biopsy needle, the mechanical properties of the soft tissue, the parameters of the puncture process and the interaction between them. This paper conducted orthogonal experiment of main cutting parameters based on single plane puncture biopsy needle, and obtained the cutting force curve of single plane puncture biopsy needle by studying the influence of the inclination angle, diameter and velocity of the single plane puncture biopsy needle on the puncture force of the biopsy needle. Stage analysis of the cutting process of biopsy needle puncture was made to determine the main influencing factors of puncture force during the cutting process, which provides a certain theoretical support for the design of new type of puncture biopsy needle and the operation of puncture biopsy.

  2. Using a Motion Sensor-Equipped Smartphone to Facilitate CT-Guided Puncture.

    PubMed

    Hirata, Masaaki; Watanabe, Ryouhei; Koyano, Yasuhiro; Sugata, Shigenori; Takeda, Yukie; Nakamura, Seiji; Akamune, Akihisa; Tsuda, Takaharu; Mochizuki, Teruhito

    2017-04-01

    To demonstrate the use of "Smart Puncture," a smartphone application to assist conventional CT-guided puncture without CT fluoroscopy, and to describe the advantages of this application. A puncture guideline is displayed by entering the angle into the application. Regardless of the angle at which the device is being held, the motion sensor ensures that the guideline is displayed at the appropriate angle with respect to gravity. The angle of the smartphone's liquid crystal display (LCD) is also detected, preventing needle deflection from the CT slice image. Physicians can perform the puncture procedure by advancing the needle using the guideline while the smartphone is placed adjacent to the patient. In an experimental puncture test using a sponge as a target, the target was punctured at 30°, 50°, and 70° when the device was tilted to 0°, 15°, 30°, and 45°, respectively. The punctured target was then imaged with a CT scan, and the puncture error was measured. The mean puncture error in the plane parallel to the LCD was less than 2°, irrespective of device tilt. The mean puncture error in the sagittal plane was less than 3° with no device tilt. However, the mean puncture error tended to increase when the tilt was increased. This application can transform a smartphone into a valuable tool that is capable of objectively and accurately assisting CT-guided puncture procedures.

  3. Retractable barrier strip

    DOEpatents

    Marts, Donna J.; Barker, Stacey G.; McQueen, Miles A.

    1996-01-01

    A portable barrier strip having retractable tire-puncture means for puncturing a vehicle tire. The tire-puncture means, such as spikes, have an armed position for puncturing a tire and a retracted position for not puncturing a tire. The strip comprises a plurality of barrier blocks having the tire-puncture means removably disposed in a shaft that is rotatably disposed in each barrier block. The shaft removably and pivotally interconnects the plurality of barrier blocks. Actuation cables cause the shaft to rotate the tire-puncture means to the armed position for puncturing a vehicle tire and to the retracted position for not puncturing the tire. Each tire-puncture means is received in a hollow-bed portion of its respective barrier block when in the retracted position. The barrier strip rests stable in its deployed position and substantially motionless as a tire rolls thereon and over. The strip is rolled up for retrieval, portability, and storage purposes, and extended and unrolled in its deployed position for use.

  4. Retractable barrier strip

    DOEpatents

    Marts, D.J.; Barker, S.G.; McQueen, M.A.

    1996-04-16

    A portable barrier strip is described having retractable tire-puncture means for puncturing a vehicle tire. The tire-puncture means, such as spikes, have an armed position for puncturing a tire and a retracted position for not puncturing a tire. The strip comprises a plurality of barrier blocks having the tire-puncture means removably disposed in a shaft that is rotatably disposed in each barrier block. The shaft removably and pivotally interconnects the plurality of barrier blocks. Actuation cables cause the shaft to rotate the tire-puncture means to the armed position for puncturing a vehicle tire and to the retracted position for not puncturing the tire. Each tire-puncture means is received in a hollow-bed portion of its respective barrier block when in the retracted position. The barrier strip rests in its deployed position and substantially motionless as a tire rolls thereon and over. The strip is rolled up for retrieval, portability, and storage purposes, and extended and unrolled in its deployed position for use. 13 figs.

  5. Validation of a novel cost effective easy to produce and durable in vitro model for kidney-puncture and PNL-Simulation.

    PubMed

    Klein, Jan Thorsten; Rassweiler, Jens; Rassweiler-Seyfried, Marie-Claire Charlotte

    2018-03-29

    Nephrolithiasis is one of the most common diseases in urology. According to the EAU Guidelines, a percutaneous nephrolitholapaxy (PNL) is recommended when treating a kidney stone >2 cm. Nowadays PNL is performed even for smaller stones (<1 cm) using miniaturized instruments. The most challenging part of any PNL is the puncture of the planned site. PNL-novice surgeons need to practice this step in a safe environment with an ideal training model. We developed and evaluated a new, easy to produce, in-vitro model for the training of the freehand puncture of the kidney. Porcine kidneys with ureters were embedded in ballistic gel. Food coloring and preservative agent were added. We used the standard imaging modalities of X-ray and ultrasound to validate the training model. An additional new technique, the iPAD guided puncture, was evaluated. Five novices and three experts conducted 12 punctures for each imaging technique. Puncture time, radiation dose, and number of attempts to a successful puncture were measured. Mann-Whitney-U, Kruskal-Wallis, and U-Tests were used for statistical analyses. The sonographic guided puncture is slightly but not significantly faster than the fluoroscopic guided puncture and the iPAD assisted puncture. Similarly, the most experienced surgeon's time for a successful puncture was slightly less than that of the residents, and the experienced surgeons needed the least attempts to perform a successful puncture. In terms of radiation exposure, the residents had a significant reduction of radiation exposure compared to the experienced surgeons. The newly developed ballistic gel kidney-puncture model is a good training tool for a variety of kidney puncture techniques, with good content, construct, and face validity.

  6. Mini access guide to simplify calyceal access during percutaneous nephrolithotomy: A novel device.

    PubMed

    Chowdhury, Puskar Shyam; Nayak, Prasant; David, Deepak; Mallick, Sujata

    2017-01-01

    A precise puncture of the renal collecting system is the most essential step for percutaneous nephrolithotomy (PCNL). There are many techniques describing this crucial first step in PCNL including the bull's eye technique, triangulation technique, free-hand technique, and gradual descensus technique. We describe a novel puncture guide to assist accurate percutaneous needle placement during bull's eye technique. The mini access guide (MAG) stabilizes the initial puncture needle by mounting it on an adjustable multidirectional carrier fixed to the patient's skin, which aids in achieving the "bull's eye" puncture. It also avoids a direct fluoroscopic exposure of the urologist's hand during the puncture. Sixty consecutive patients with solitary renal calculus were randomized to traditional hand versus MAG puncture during bull's eye technique of puncture and the fluoroscopy time was assessed. The median fluoroscopy screening time for traditional free-hand bull's eye and MAG-guided bull's eye puncture (fluoroscopic screening time for puncture) was 55 versus 21 s ( P = 0.001) and the median time to puncture was 80 versus 55 s ( P = 0.052), respectively. Novice residents also learned puncture technique faster with MAG on simulator. The MAG is a simple, portable, cheap, and novel assistant to achieve successful PCNL puncture. It would be of great help for novices to establish access during their learning phase of PCNL. It would also be an asset toward significantly decreasing the radiation dose during PCNL access.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hirata, Masaaki, E-mail: masaaki314@gmail.com; Watanabe, Ryouhei; Koyano, Yasuhiro

    PurposeTo demonstrate the use of “Smart Puncture,” a smartphone application to assist conventional CT-guided puncture without CT fluoroscopy, and to describe the advantages of this application.Materials and MethodsA puncture guideline is displayed by entering the angle into the application. Regardless of the angle at which the device is being held, the motion sensor ensures that the guideline is displayed at the appropriate angle with respect to gravity. The angle of the smartphone’s liquid crystal display (LCD) is also detected, preventing needle deflection from the CT slice image. Physicians can perform the puncture procedure by advancing the needle using the guidelinemore » while the smartphone is placed adjacent to the patient. In an experimental puncture test using a sponge as a target, the target was punctured at 30°, 50°, and 70° when the device was tilted to 0°, 15°, 30°, and 45°, respectively. The punctured target was then imaged with a CT scan, and the puncture error was measured.ResultsThe mean puncture error in the plane parallel to the LCD was less than 2°, irrespective of device tilt. The mean puncture error in the sagittal plane was less than 3° with no device tilt. However, the mean puncture error tended to increase when the tilt was increased.ConclusionThis application can transform a smartphone into a valuable tool that is capable of objectively and accurately assisting CT-guided puncture procedures.« less

  8. The effect of skin entry site, needle angulation and soft tissue compression on simulated antegrade and retrograde femoral arterial punctures: an anatomical study using Cartesian co-ordinates derived from CT angiography.

    PubMed

    Tam, Matthew D B S; Lewis, Mark

    2012-10-01

    Safe femoral arterial access is an important procedural step in many interventional procedures and variations of the anatomy of the region are well known. The aim of this study was to redefine the anatomy relevant to the femoral arterial puncture and simulate the results of different puncture techniques. A total of 100 consecutive CT angiograms were used and regions of interest were labelled giving Cartesian co-ordinates which allowed determination of arterial puncture site relative to skin puncture site, the bifurcation and inguinal ligament (ING). The ING was lower than defined by bony landmarks by 16.6 mm. The femoral bifurcation was above the inferior aspect of the femoral head in 51% and entirely medial to the femoral head in 1%. Simulated antegrade and retrograde punctures with dogmatic technique, using a 45-degree angle would result in a significant rate of high and low arterial punctures. Simulated 50% soft tissue compression also resulted in decreased rate of high retrograde punctures but an increased rate of low antegrade punctures. Use of dogmatic access techniques is predicted to result in an unacceptably high rate of dangerous high and low punctures. Puncture angle and geometry can be severely affected by patient obesity. The combination of fluoroscopy to identify entry point, ultrasound-guidance to identify the femoral bifurcation and soft tissue compression to improve puncture geometry are critical for safe femoral arterial access.

  9. Percutaneous puncture of renal calyxes guided by a novel device coupled with ultrasound

    PubMed Central

    Chan, Chen Jen; Srougi, Victor; Tanno, Fabio Yoshiaki; Jordão, Ricardo Duarte; Srougi, Miguel

    2015-01-01

    ABSTRACT Purpose: To evaluate the efficiency of a novel device coupled with ultrassound for renal percutaneous puncture. Materials and Methods: After establishing hydronephrosis, ten pigs had three calyxes of each kidney punctured by the same urology resident, with and without the new device (“Punctiometer”). Time for procedure completion, number of attempts to reach the calyx, puncture precision and puncture complications were recorded in both groups and compared. Results: Puncture success on the first attempt was achieved in 25 punctures (83%) with the Punctiometer and in 13 punctures (43%) without the Punctiometer (p=0.011). The mean time required to perform three punctures in each kidney was 14.5 minutes with the Punctiometer and 22.4 minutes without the Punctiometer (p=0.025). The only complications noted were renal hematomas. In the Punctiometer group, all kidneys had small hematomas. In the no Punctiometer group 80% had small hematomas, 10% had a medium hematoma and 10% had a big hematoma. There was no difference in complications between both groups. Conclusions: The Punctiometer is an effective device to increase the likelihood of an accurate renal calyx puncture during PCNL, with a shorter time required to perform the procedure. PMID:26689521

  10. [Observation on therapeutic effect of electroacupuncture at Tianshu (ST 25) with deep needling technique on functional constipation].

    PubMed

    Wang, Cheng-Wei; He, Hong-Bo; Li, Ning; Wen, Qian; Liu, Zhi-Shun

    2010-09-01

    To probe into a better therapeutic method for functional constipation. Ninety-five cases of functional constipation were randomly divided into deep puncture at ST 25 group (48 cases), shallow puncture at ST 25 group (24 cases) and medication group (23 cases). In deep puncture at ST 25 group, Tianshu (ST 25) was punctured deeply to the peritoneum, with electric stimulation. In shallow puncture at ST 25 group, Tianshu (ST 25) was punctured shallowly, 5 mm beneath the skin, with electric stimulation. In medication group, Duphalac was administered orally. These cases were treated continuously for 4 weeks in 3 groups and followed up for 6 months. It was to observe the numbers of person who had defecation 4 times a week, difference in weekly defecation frequency and the difference in the Cleveland Clinic Score (CCS). In deep puncture at ST 25 group, the frequency of weekly defecation and the numbers of person who had defecation 4 times a week increased and CCS decreased, which were similar to the efficacy in shallow puncture at ST 25 group (all P > 0.05). But the efficacy of both ST 25 groups was superior to that in medication group (both P < 0.05). In comparison, the deep puncture at ST 25 group acted more quickly than either shallow puncture at ST 25 group or medication group and its efficacy remained much longer. The deep puncture at ST 25 with electric stimulation presents similar efficacy on functional constipation as shallow puncture at ST 25, but it acts more quickly than shallow puncture at ST 25, both of them are more advantageous than medication and the long-term efficacy is better.

  11. The Tension and Puncture Properties of HDPE Geomembrane under the Corrosion of Leachate.

    PubMed

    Xue, Qiang; Zhang, Qian; Li, Zhen-Ze; Xiao, Kai

    2013-09-17

    To investigate the gradual failure of high-density polyethylene (HDPE) geomembrane as a result of long-term corrosion, four dynamic corrosion tests were conducted at different temperatures and durations. By combining tension and puncture tests, we systematically studied the variation law of tension and puncture properties of the HDPE geomembrane under different corrosion conditions. Results showed that tension and puncture failure of the HDPE geomembrane was progressive, and tensile strength in the longitudinal grain direction was evidently better than that in the transverse direction. Punctures appeared shortly after puncture force reached the puncture strength. The tensile strength of geomembrane was in inversely proportional to the corrosion time, and the impact of corrosion was more obvious in the longitudinal direction than transverse direction. As corrosion time increased, puncture strength decreased and corresponding deformation increased. As with corrosion time, the increase of corrosion temperature induced the decrease of geomembrane tensile strength. Tensile and puncture strength were extremely sensitive to temperature. Overall, residual strength had a negative correlation with corrosion time or temperature. Elongation variation increased initially and then decreased with the increase in temperature. However, it did not show significant law with corrosion time. The reduction in puncture strength and the increase in puncture deformation had positive correlations with corrosion time or temperature. The geomembrane softened under corrosion condition. The conclusion may be applicable to the proper designing of the HDPE geomembrane in landfill barrier system.

  12. Semi-analytical approach to estimate railroad tank car shell puncture

    DOT National Transportation Integrated Search

    2011-03-16

    This paper describes the development of engineering-based equations to estimate the puncture resistance of railroad tank cars under a generalized shell or side impact scenario. Resistance to puncture is considered in terms of puncture velocity, which...

  13. Transforaminal Lumbar Puncture: An Alternative Technique in Patients with Challenging Access.

    PubMed

    Nascene, D R; Ozutemiz, C; Estby, H; McKinney, A M; Rykken, J B

    2018-05-01

    Interlaminar lumbar puncture and cervical puncture may not be ideal in all circumstances. Recently, we have used a transforaminal approach in selected situations. Between May 2016 and December 2017, twenty-six transforaminal lumbar punctures were performed in 9 patients (25 CT-guided, 1 fluoroscopy-guided). Seven had spinal muscular atrophy and were referred for intrathecal nusinersen administration. In 2, CT myelography was performed via transforaminal lumbar puncture. The lumbar posterior elements were completely fused in 8, and there was an overlying abscess in 1. The L1-2 level was used in 2; the L2-3 level, in 10; the L3-4 level, in 12; and the L4-5 level, in 2 procedures. Post-lumbar puncture headache was observed on 4 occasions, which resolved without blood patching. One patient felt heat and pain at the injection site that resolved spontaneously within hours. One patient had radicular pain that resolved with conservative treatment. Transforaminal lumbar puncture may become an effective alternative to classic interlaminar lumbar puncture or cervical puncture. © 2018 by American Journal of Neuroradiology.

  14. Retractable barrier strip

    DOEpatents

    Marts, Donna J.; Barker, Stacey G.; Wowczuk, Andrew; Vellenoweth, Thomas E.

    2002-01-01

    A portable barrier strip having retractable tire-puncture spikes for puncturing a vehicle tire. The tire-puncture spikes have an armed position for puncturing a tire and a retracted position for not puncturing a tire. The strip comprises a plurality of barrier blocks having the tire-puncture spikes removably disposed in a shaft that is rotatably disposed in each barrier block. The plurality of barrier blocks hare hingedly interconnected by complementary hinges integrally formed into the side of each barrier block which allow the strip to be rolled for easy storage and retrieval, but which prevent irregular or back bending of the strip. The shafts of adjacent barrier blocks are pivotally interconnected via a double hinged universal joint to accommodate irregularities in a roadway surface and to transmit torsional motion of the shaft from block to block. A single flexshaft cable is connected to the shaft of an end block to allow a user to selectively cause the shafts of a plurality of adjacently connected barrier blocks to rotate the tire-puncture spikes to the armed position for puncturing a vehicle tire, and to the retracted position for not puncturing the tire. The flexshaft is provided with a resiliently biased retracting mechanism, and a release latch for allowing the spikes to be quickly retracted after the intended vehicle tire is punctured.

  15. Blood patch rates after lumbar puncture with Whitacre versus Quincke 22- and 20-gauge spinal needles.

    PubMed

    Hatfield, Malcolm K; Handrich, Stephen J; Willis, Jeffrey A; Beres, Robert A; Zaleski, George X

    2008-06-01

    The objective of our study was to compare the incidence of blood patch as the best objective indicator of postdural puncture headache after elective fluoroscopic lumbar puncture with the use of a 22-gauge Whitacre (pencil point) needle versus standard 22- and 20-gauge Quincke (bevel-tip) needles and to determine the best level of puncture. The records of 724 consecutive patients who were referred to St. Mary's Medical Center department of radiology for fluoroscopic lumbar puncture from January 2003 through April 2007 were retrospectively reviewed. Emergency requests (191) were discarded along with those for patients with clinical signs of pseudotumor cerebri (21), normal pressure hydrocephalus (3), and failed attempts (4). The collective total was 505 elective lumbar punctures. The blood patch rate for the 22-gauge Whitacre needle was 4.2%. The result for the 22-gauge Quincke point needle was 15.1% whereas that for the 20-gauge Quincke point needle was 29.6%. In addition, the level of puncture showed a blood patch rate that increased as the level of lumbar puncture lowered. The highest level of lumbar puncture was L1-L2 with the lowest recorded level being L5-S1. The Whitacre needle is associated with a significantly lower incidence of blood patch rate after lumbar puncture. The highest level of puncture (L1-L2) also provides the lowest level of blood patch rate.

  16. The Tension and Puncture Properties of HDPE Geomembrane under the Corrosion of Leachate

    PubMed Central

    Xue, Qiang; Zhang, Qian; Li, Zhen-Ze; Xiao, Kai

    2013-01-01

    To investigate the gradual failure of high-density polyethylene (HDPE) geomembrane as a result of long-term corrosion, four dynamic corrosion tests were conducted at different temperatures and durations. By combining tension and puncture tests, we systematically studied the variation law of tension and puncture properties of the HDPE geomembrane under different corrosion conditions. Results showed that tension and puncture failure of the HDPE geomembrane was progressive, and tensile strength in the longitudinal grain direction was evidently better than that in the transverse direction. Punctures appeared shortly after puncture force reached the puncture strength. The tensile strength of geomembrane was in inversely proportional to the corrosion time, and the impact of corrosion was more obvious in the longitudinal direction than transverse direction. As corrosion time increased, puncture strength decreased and corresponding deformation increased. As with corrosion time, the increase of corrosion temperature induced the decrease of geomembrane tensile strength. Tensile and puncture strength were extremely sensitive to temperature. Overall, residual strength had a negative correlation with corrosion time or temperature. Elongation variation increased initially and then decreased with the increase in temperature. However, it did not show significant law with corrosion time. The reduction in puncture strength and the increase in puncture deformation had positive correlations with corrosion time or temperature. The geomembrane softened under corrosion condition. The conclusion may be applicable to the proper designing of the HDPE geomembrane in landfill barrier system. PMID:28788321

  17. Isocentric Navigation of Percutaneous Endoscopic Transforaminal Discectomy at the L5/S1 Level in Difficult Puncture Cases: A Technical Note.

    PubMed

    Fan, Guoxin; Wang, Teng; Hu, Shuo; Guan, Xiaofei; Gu, Xin; He, Shisheng

    2017-05-01

    Accurate puncture during percutaneous transforaminal endoscopic discectomy at the L5/S1 level in cases with high iliac crest and narrow foramen were difficult, even though the difficulties of foraminoplasty could be overcome by advanced instruments like reamers. The report aimed to describe an isocentric navigation technique with a definite pathway in difficult puncture cases at the L5/S1 level. Technical note. Difficult punctures were defined as over 10 punctures of the needle before obtaining an ideal puncture location by senior surgeons with experience of over 500 percutaneous endoscopic transforaminal discectomy (PETD) cases. A total of 124 punctures were recorded in 11 difficult puncture cases at the L5/S1 level. A definite pathway was created by an isocentric navigation theory, which was based on a surface locator and an arch-guided device. The surface locator was used to rapidly and accurately identify the puncture target with the recognition of the surrounding rods under fluoroscopy. The arch-guided device can ensure that the puncture target always remains at the center of a virtual sphere. We recorded the puncture times, fluoroscopy exposure times, radiation exposure time, operative time, visual analog scale (VAS) score, Japanese Orthopeadic Association (JOA) score, and patient satisfaction. The average puncture times were significantly reduced to 1.27 with the arch-guided device compared with conventional puncture methods (P < 0.05). The average operative time was 90.09 ± 11.00 minutes and the fluoroscopy times were 53.36 ± 5.85. The radiation exposure time was 50.91 ± 5.20 seconds. VAS score of leg and back pain, as well as JOA score, were all significantly improved after surgery (P < 0.05). The excellent and good rate of satisfaction was 90.91%. No major complications, including cerebral fluid leakage, surgical infection, and postoperative nerve root injury, were recorded in this small sample. This was a small-sample study with a short follow-up. The novel isocentric navigation technique with a definite pathway is practical and effective in reducing puncture times among difficult puncture cases at the L5/S1 level, which may contribute to the capacity of PETD at the L5/S1 level.

  18. Evaluation of semi-empirical analyses for tank car puncture velocity, part II : correlations with engineering analyses

    DOT National Transportation Integrated Search

    2001-11-01

    This report is the second in a series focusing on methods to determine the puncture velocity of railroad tank car shells. In this context, puncture velocity refers to the impact velocity at which a coupler will completely pierce the shell and punctur...

  19. Evaluation of semi-empirical analyses for railroad tank car puncture velocity, part 1 : correlations with experimental data

    DOT National Transportation Integrated Search

    2001-11-01

    This report is the first in a two-part series that focuses on methodologies to determine the puncture velocity of tank car shells. In this context, puncture velocity refers to the impact velocity at which a coupler will puncture the tank. In this rep...

  20. MRimaging findings after ventricular puncture in patients with SAH.

    PubMed

    Tominaga, J; Shimoda, M; Oda, S; Kumasaka, A; Yamazaki, K; Tsugane, R

    2001-11-01

    Using magnetic resonance (MR) imaging, we studied brain injury from ventricular puncture performed during craniotomy in the acute stage of subarachnoid hemorrhage (SAH). 80 patients underwent craniotomy for aneurysm obliteration within 48 hr after SAH, ventricular puncture for drainage of cerebrospinal fluid (CSF) was performed to reduce intracranial pressure. MR imaging was performed within 3 days following surgery to measure the size of the lesion, and was repeated on postoperative days 14 and 30. Of the 80 patients with ventricular puncture preceding craniotomy, 65 (81%) showed MR evidence of brain injury from the puncture. Overall, 149 lesions were detected. According to coronal images, cortical injuries (54 cases), penetrating injury to tracts along the ventricular tube (55 cases), caudate injury (25 cases), and corpus callosum injury (15 cases). Brain injuries from ventricular puncture did not correlate significantly to patient outcome. While ventricular puncture and drainage of CSF can readily be performed to decrease brain volume at the time of craniotomy in acute-stage SAH, neurosurgeons should be aware of a surprisingly high incidence of brain injury complicating puncture.

  1. Preliminary clinical trial in percutaneous nephrolithotomy using a real-time navigation system for percutaneous kidney access

    NASA Astrophysics Data System (ADS)

    Rodrigues, Pedro L.; Moreira, António H. J.; Rodrigues, Nuno F.; Pinho, A. C. M.; Fonseca, Jaime C.; Lima, Estevão.; Vilaça, João. L.

    2014-03-01

    Background: Precise needle puncture of renal calyces is a challenging and essential step for successful percutaneous nephrolithotomy. This work tests and evaluates, through a clinical trial, a real-time navigation system to plan and guide percutaneous kidney puncture. Methods: A novel system, entitled i3DPuncture, was developed to aid surgeons in establishing the desired puncture site and the best virtual puncture trajectory, by gathering and processing data from a tracked needle with optical passive markers. In order to navigate and superimpose the needle to a preoperative volume, the patient, 3D image data and tracker system were previously registered intraoperatively using seven points that were strategically chosen based on rigid bone structures and nearby kidney area. In addition, relevant anatomical structures for surgical navigation were automatically segmented using a multi-organ segmentation algorithm that clusters volumes based on statistical properties and minimum description length criterion. For each cluster, a rendering transfer function enhanced the visualization of different organs and surrounding tissues. Results: One puncture attempt was sufficient to achieve a successful kidney puncture. The puncture took 265 seconds, and 32 seconds were necessary to plan the puncture trajectory. The virtual puncture path was followed correctively until the needle tip reached the desired kidney calyceal. Conclusions: This new solution provided spatial information regarding the needle inside the body and the possibility to visualize surrounding organs. It may offer a promising and innovative solution for percutaneous punctures.

  2. Skin Punctures in Preterm Infants in the First 2 Weeks of Life.

    PubMed

    Finn, Daragh; Butler, Daryl; Sheehan, Orla; Livingstone, Vicki; Dempsey, Eugene M

    2018-05-23

     The objective of this study was to investigate frequency and trends of skin punctures in preterm infants.  A prospective audit of preterm infants less than 35 weeks admitted over a 6-month period to a tertiary neonatal intensive care unit. Each skin puncture performed in the first 2 weeks of life was documented in a specifically designed audit sheet.  Ninety-nine preterm infants were enrolled. Infants born at < 32 weeks' gestation had significantly more skin punctures than infants > 32 weeks (median skin punctures 26.5 vs. 17, p -value < 0.05). The highest frequency of skin punctures occurred during the first week of life for infants > 28 weeks' gestation (medians 17.5 in 28-31 + 6 weeks' gestation, and 15 in > 32 weeks), and during the second week of life for those born at < 28 weeks (median 17.5). Infants with sepsis had more skin punctures ( p -value < 0.001), but this was not significant on multivariate analysis. Median skin punctures in the second week of life were statistically higher in the sepsis group on multivariate analysis (odds ratio: 1.07, 95% confidence interval: 1.00-1.14, p  = 0.041).  Frequency of skin punctures is influenced by gestational age and postnatal age. Skin punctures were not an independent risk factor for sepsis. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  3. [Possibility of cauda equina nerve root damage from lumbar punctures performed with 25-gauge Quincke and Whitacre needles].

    PubMed

    Reina, M A; López, A; Villanueva, M C; De Andrés, J A; Martín, S

    2005-05-01

    To assess the possibility of puncturing nerve roots in the cauda equina with spinal needles with different point designs and to quantify the number of axons affected. We performed in vitro punctures of human nerve roots taken from 3 fresh cadavers. Twenty punctures were performed with 25-gauge Whitacre needles and 40 with 25-gauge Quincke needles; half the Quincke needle punctures were carried out with the point perpendicular to the root and the other half with the point parallel to it. The samples were studied by optical and scanning electron microscopy. The possibility of finding the needle orifece inserted inside the nerve was assessed. On a photographic montage, we counted the number of axons during a hypothetical nerve puncture. Nerve roots used in this study were between 1 and 2.3 mm thick, allowing the needle to penetrate the root in the 52 samples studied. The needle orifice was never fully located inside the nerve in any of the samples. The numbers of myelinized axons affected during nerve punctures 0.2 mm deep were 95, 154, and 81 for Whitacre needles, Quincke needles with the point held perpendicular, or the same needle type held parallel, respectively. During punctures 0.5 mm deep, 472, 602, and 279 were affected for each puncture group, respectively. The differences in all cases were statistically significant. It is possible to achieve intraneural puncture with 25-gauge needles. However, full intraneural placement of the orifice of the needle is unlikely. In case of nerve trauma, the damage could be greater if puncture is carried out with a Quincke needle with the point inserted perpendicular to the nerve root.

  4. [Diagnostic accuracy research of needle puncture biopsy during operation for pulmonary single nodules].

    PubMed

    Chen, Jin-feng; Liu, Yi-nan; Wu, Nan; Feng, Yuan; Wang, Jia; Lü, Chao; Wang, Yu-zhao; Pei, Yu-quan; Yan, Shi; Zheng, Qing-feng; Zhang, Li-jian; Yang, Yue

    2012-04-01

    To investigate the diagnostic accuracy of needle puncture biopsy and pathological examination of frozen during operation for pulmonary nodules, and whether this diagnostic method can replace tumor resection examination. Totally 50 patients (28 males and 22 females, average age was 59 years) who had the single nodule after imaging examination without any pathological diagnostic from January to October 2010 were selected in this research work. During open operation or video assisted thoracic surgery, needle (14 G model) was used to puncture biopsy for pathological examination of frozen. All the adverse events during puncture biopsy would be recorded. The resection specimens would be accepted paraffin pathological examination. The relationship between puncture frozen pathological and paraffin pathological examination was analyzed. All tumor sizes were ranged from 1.0 cm × 0.6 cm to 5.6 cm × 9.0 cm. The paraffin pathological examination after operation as the golden standard, there were 7 cases of benign tumor and 43 cases of malignant tumor. The diagnostic sensitivity of puncture biopsy was 90.7%, the specificity was 100%, the positive predictive value was 100% and the negative predictive value was 63.6%. There were 11 cases of benign tumor diagnosed by needle puncture biopsy, among which 4 cases were proved as malignant tumor by paraffin pathology, and the false negative rate was 9.3%. The main risk of puncture biopsy was bleeding after puncture immediately, and the rate was 4.0% (2/50). The puncture biopsy during operation had a high specificity for malignant lung tumor, and there was a certain false negative rate for benign tumor. Puncture biopsy and pathological examination of frozen tissue can replace tumor section biopsy in a way.

  5. Continuous thermographic observation may predict extravasation in chemotherapy-treated patients.

    PubMed

    Oya, Maiko; Murayama, Ryoko; Oe, Makoto; Yabunaka, Koichi; Tanabe, Hidenori; Takahashi, Toshiaki; Matsui, Yuko; Otomo, Eiko; Komiyama, Chieko; Sanada, Hiromi

    2017-06-01

    Extravasation, or leakage of vesicant drugs into subcutaneous tissues, causes serious complications such as induration and necrosis in chemotherapy-treated patients. As macroscopic observation may overlook symptoms during infusion, we focused on skin temperature changes at puncture sites and studied thermographic patterns related to induration or necrosis caused by extravasation. Outpatients undergoing chemotherapy using peripheral intravenous catheters were enrolled in this prospective observational study. We filmed and classified infrared thermography movies of puncture sites during infusion; ultrasonography was also utilized at puncture sites to observe the subcutaneous condition. Multiple logistic regression analysis was performed to examine the association of thermographic patterns with induration or necrosis observed on the next chemotherapy day. Differences in patient characteristics, puncture sites, and infusions were analyzed by Mann-Whitney's U test and Fisher's exact test according to thermographic patterns. Eight patients developed induration among 74 observations in 62 patients. Among six thermographic patterns, a fan-shaped lower temperature area gradually spreading from the puncture site (fan at puncture site) was significantly associated with induration. Ultrasonography revealed that catheters of patients with fan at puncture site remained in the vein at the end of infusion, indicating that the infusion probably leaked from the puncture site. Patients with fan at puncture site had no significant differences in characteristics and infusion conditions compared with those with the other five thermographic patterns. We determined that fan at puncture site was related to induration caused by extravasation. Continuous thermographic observation may enable us to predict adverse events of chemotherapy. Copyright © 2017. Published by Elsevier Ltd.

  6. The training and learning process of transseptal puncture using a modified technique.

    PubMed

    Yao, Yan; Ding, Ligang; Chen, Wensheng; Guo, Jun; Bao, Jingru; Shi, Rui; Huang, Wen; Zhang, Shu; Wong, Tom

    2013-12-01

    As the transseptal (TS) puncture has become an integral part of many types of cardiac interventional procedures, its technique that was initial reported for measurement of left atrial pressure in 1950s, continue to evolve. Our laboratory adopted a modified technique which uses only coronary sinus catheter as the landmark to accomplishing TS punctures under fluoroscopy. The aim of this study is prospectively to evaluate the training and learning process for TS puncture guided by this modified technique. Guided by the training protocol, TS puncture was performed in 120 consecutive patients by three trainees without previous personal experience in TS catheterization and one experienced trainer as a controller. We analysed the following parameters: one puncture success rate, total procedure time, fluoroscopic time, and radiation dose. The learning curve was analysed using curve-fitting methodology. The first attempt at TS crossing was successful in 74 (82%), a second attempt was successful in 11 (12%), and 5 patients failed to puncture the interatrial septal finally. The average starting process time was 4.1 ± 0.8 min, and the estimated mean learning plateau was 1.2 ± 0.2 min. The estimated mean learning rate for process time was 25 ± 3 cases. Important aspects of learning curve can be estimated by fitting inverse curves for TS puncture. The study demonstrated that this technique was a simple, safe, economic, and effective approach for learning of TS puncture. Base on the statistical analysis, approximately 29 TS punctures will be needed for trainee to pass the steepest area of learning curve.

  7. Ultrasound-guided lumbar puncture in pediatric patients: technical success and safety.

    PubMed

    Pierce, David B; Shivaram, Giri; Koo, Kevin S H; Shaw, Dennis W W; Meyer, Kirby F; Monroe, Eric J

    2018-06-01

    Disadvantages of fluoroscopically guided lumbar puncture include delivery of ionizing radiation and limited resolution of incompletely ossified posterior elements. Ultrasound (US) allows visualization of critical soft tissues and the cerebrospinal fluid (CSF) space without ionizing radiation. To determine the technical success and safety of US-guided lumbar puncture in pediatric patients. A retrospective review identified all patients referred to interventional radiology for lumbar puncture between June 2010 and June 2017. Patients who underwent lumbar puncture with fluoroscopic guidance alone were excluded. For the remaining procedures, technical success and procedural complications were assessed. Two hundred and one image-guided lumbar punctures in 161 patients were included. Eighty patients (43%) had previously failed landmark-based attempts. One hundred ninety-six (97.5%) patients underwent lumbar puncture. Five procedures (2.5%) were not attempted after US assessment, either due to a paucity of CSF or unsafe window for needle placement. Technical success was achieved in 187 (95.4%) of lumbar punctures attempted with US guidance. One hundred seventy-seven (90.3%) were technically successful with US alone (age range: 2 days-15 years, weight range: 1.9-53.1 kg) and an additional 10 (5.1%) were successful with US-guided thecal access and subsequent fluoroscopic confirmation. Three (1.5%) cases were unsuccessful with US guidance but were subsequently successful with fluoroscopic guidance. Of the 80 previously failed landmark-based lumbar punctures, 77 (96.3%) were successful with US guidance alone. There were no reported complications. US guidance is safe and effective for lumbar punctures and has specific advantages over fluoroscopy in pediatric patients.

  8. Elastic and viscoelastic mechanical properties of brain tissues on the implanting trajectory of sub-thalamic nucleus stimulation.

    PubMed

    Li, Yan; Deng, Jianxin; Zhou, Jun; Li, Xueen

    2016-11-01

    Corresponding to pre-puncture and post-puncture insertion, elastic and viscoelastic mechanical properties of brain tissues on the implanting trajectory of sub-thalamic nucleus stimulation are investigated, respectively. Elastic mechanical properties in pre-puncture are investigated through pre-puncture needle insertion experiments using whole porcine brains. A linear polynomial and a second order polynomial are fitted to the average insertion force in pre-puncture. The Young's modulus in pre-puncture is calculated from the slope of the two fittings. Viscoelastic mechanical properties of brain tissues in post-puncture insertion are investigated through indentation stress relaxation tests for six interested regions along a planned trajectory. A linear viscoelastic model with a Prony series approximation is fitted to the average load trace of each region using Boltzmann hereditary integral. Shear relaxation moduli of each region are calculated using the parameters of the Prony series approximation. The results show that, in pre-puncture insertion, needle force almost increases linearly with needle displacement. Both fitting lines can perfectly fit the average insertion force. The Young's moduli calculated from the slope of the two fittings are worthy of trust to model linearly or nonlinearly instantaneous elastic responses of brain tissues, respectively. In post-puncture insertion, both region and time significantly affect the viscoelastic behaviors. Six tested regions can be classified into three categories in stiffness. Shear relaxation moduli decay dramatically in short time scales but equilibrium is never truly achieved. The regional and temporal viscoelastic mechanical properties in post-puncture insertion are valuable for guiding probe insertion into each region on the implanting trajectory.

  9. Emergency airway puncture

    MedlinePlus

    ... support for only a very short period of time. Alternative Names Needle cricothyrotomy Images Emergency airway puncture Cricoid cartilage Emergency airway puncture - series References Hebert RB, Bose S, Mace SE. Cricothyrotomy and ...

  10. Establishment of temporomandibular joint puncture technique in rats using in vivo micro-computed tomography (R_mCT®)

    PubMed Central

    Kameoka, S; Matsumoto, K; Kai, Y; Yonehara, Y; Arai, Y; Honda, K

    2010-01-01

    The aim of the report was to establish puncture techniques for the temporomandibular joint (TMJ) cavity in rats. The experimental sample comprised 30 male Sprague–Dawley rats. Under general anaesthesia the superior joint cavity of the rat was punctured either laterally (lateral puncture technique (LPT), n = 11), anteriorly (anterosuperior puncture technique (ASPT), n = 13) or anteroinferior puncture technique (AIPT), n = 6) using a 27-gauge needle. After the tip of the needle was confirmed by micro-CT (R-mCT®, Rigaku, Tokyo, Japan) located on the mandibular fossa, 0.05 ml of contrast media was injected under micro-CT fluoroscopic guidance. After confirmation that the joint cavity was filled with contrast media, micro-CT imaging was carried out. The puncture for LPT was accurate in 5 of the 11 animals. The ASPT was accurate in all 13 animals. The AIPT punctured 3 of the 6 animals. Furthermore, the ASPT and AIPT demonstrated improved preservation of the needle; it was harder to detach the needle, which led to greater stability. These results suggest that ASPT assisted by R-mCT® is useful for basic research, including drug discovery and pathogenesis of TMJ diseases. PMID:20841463

  11. Lumbar puncture opening pressure is not a reliable measure of intracranial pressure in children.

    PubMed

    Cartwright, Cathy; Igbaseimokumo, Usiakimi

    2015-02-01

    There is very little data correlating lumbar puncture pressures to formal intracranial pressure monitoring despite the widespread use of both procedures. The hypothesis was that lumbar puncture is a single-point measurement and hence it may not be a reliable evaluation of intracranial pressure. The study was therefore carried out to compare lumbar puncture opening pressures with the Camino bolt intracranial pressure monitor in children. Twelve children with a mean age of 8.5 years who had both lumbar puncture and intracranial pressure monitoring were analyzed. The mean lumbar puncture opening pressure was 22.4 mm Hg versus a mean Camino bolt intracranial pressure of 7.8 mm Hg (P < .0001). Lumbar puncture therefore significantly overestimates the intracranial pressure in children. There were no complications from the intracranial pressure monitoring, and the procedure changed the treatment of all 12 children avoiding invasive operative procedures in most of the patients. © The Author(s) 2014.

  12. Puncture Wounds

    MedlinePlus

    ... into the wound during a puncture, along with dirt and debris from the object. All puncture wounds ... object, such as a rusty nail, the more dirt and debris are dragged into the wound, increasing ...

  13. Comparison of blood chemistry values for samples collected from juvenile chinook salmon by three methods

    USGS Publications Warehouse

    Congleton, J.L.; LaVoie, W.J.

    2001-01-01

    Thirteen blood chemistry indices were compared for samples collected by three commonly used methods: caudal transection, heart puncture, and caudal vessel puncture. Apparent biases in blood chemistry values for samples obtained by caudal transection were consistent with dilution with tissue fluids: alanine aminotransferase (ALT), aspartate aminotransferase (AST), lactate dehydrogenase (LDH), creatine kinase (CK), triglyceride, and K+ were increased and Na+ and Cl- were decreased relative to values for samples obtained by caudal vessel puncture. Some enzyme activities (ALT, AST, LDH) and K+ concentrations were also greater in samples taken by heart puncture than in samples taken by caudal vessel puncture. Of the methods tested, caudal vessel puncture had the least effect on blood chemistry values and should be preferred for blood chemistry studies on juvenile salmonids.

  14. Management of pedal puncture wounds.

    PubMed

    Belin, Ronald; Carrington, Scott

    2012-07-01

    Puncture wounds of the foot are a common injury, and infection associated with these injuries may result in considerable morbidity. The pathophysiology and management of a puncture wound is dependent on the material that punctures the foot, the location and depth of the wound, time to presentation, footwear, and underlying health status of the patient. Puncture wounds should not be treated lightly, so accurate diagnosis, assessment, and treatment are paramount. Early incision and drainage, vaccination, and the use of proper antibiotics can lead to positive outcomes and prevent limb-threatening circumstances. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. Comparison of post-dural puncture headache and low back pain between 23 and 25 gauge Quincke spinal needles in patients over 60 years: randomized, double-blind controlled trial.

    PubMed

    Kim, Meehyoung; Yoon, Haesang

    2011-11-01

    Even though the use of a 25 gauge or smaller Quincke needle is recommended for spinal anesthesia to reduce post-dural puncture headache in Korea, lumbar puncture in older patients using a 25 gauge or smaller Quincke needle can be difficult. However, most previous studies concerning post-dural puncture headache have chosen children, parturients, and young adults as study participants. The study compared post-dural puncture headache, post-operative back pain, and the number of lumbar puncture attempts using a 23 or 25 gauge Quincke needle for spinal anesthesia of Korean patients >60-years-of-age. Randomized, double-blinded controlled trial. The 53 participants who underwent orthopedic surgery under spinal anesthesia were recruited by informed notices from December 2006 through August 2007 at a 200-bed general hospital located in Kyunggido. Inclusion criteria were an age >60 years, ASA I-II, and administration of patient controlled analgesia for the first 48 h post-operatively. The 53 patients were randomly allocated to either the experimental (23 gauge Quincke needle) or control group (25 gauge Quincke needle). All patients had 24 h bed rest post-operatively. Post-dural puncture headache was assessed by the Dittmann Scale and post-operative back pain was assessed by a visual analogue scale at 24, 48, and 72 h post-operatively. The statistical methods included the Mann-Whitney U-test and Spearman correlation. There were no differences in post-dural puncture headache, and post-operative back pain at 24, 48, and 72 h post-operatively, and no differences in the number of lumbar punctures, with the 23 and 25 gauge Quincke needle. Forty-eight hour post-operative back pain was positively associated with the number of lumbar punctures (p=.036) and age (p=.040). There were no statistically significant associations among post-dural puncture headache, the number of lumbar punctures, and 48 h post-operative back pain. Pre-operative back pain was positively associated with 48 h post-operative back pain (p<.001). The choice of a 23 or 25 gauge Quincke needle for spinal anesthesia has no significant influence on post-dural puncture headache and post-operative back pain for Korean patients greater than 60-years-of-age. The 23 gauge Quincke needle is an option for lumbar punctures in this patient population. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Effectiveness of sublingual nitroglycerin before puncture compared with conventional intra-carterial nitroglycerin in transradial procedures: a randomized trial.

    PubMed

    Turan, Burak; Daşlı, Tolga; Erkol, Ayhan; Erden, İsmail

    2015-01-01

    Sublingual (SL) nitroglycerin administered before radial artery puncture can improve cannulation success and decrease the incidence of radial artery spasm (RAS) compared with intra-arterial (IA) nitroglycerin in transradial procedures. Patients undergoing diagnostic transradial angiography were randomized to IA (200 mcg) or SL (400 mcg) nitroglycerin. Primary endpoints were puncture time and puncture attempts. Secondary endpoint was the incidence of RAS. Total of 101 participants (mean age 60±11years, 53% male) were randomized (51 in IA and 50 in SL groups). Puncture time (50 [36-75] vs 50 [35-90] sec), puncture attempts (1.18±0.48 vs 1.20±0.49), multiple punctures (13.7 vs 16.0%) and RAS (19.6 vs 24.0%) were not statistically different between IA vs SL groups respectively. A composite endpoint of all adverse events related to transradial angiography (multiple punctures, RAS, access site crossover, hypotension/bradycardia associated with nitroglycerin and radial artery occlusion) was very similar in IA vs SL groups (39 vs 40%, respectively). However puncture time was significantly longer with SL nitroglycerin in patients <1.65m height (47 [36-66] vs 63 [41-110] sec, p=0.042). Multiple punctures seemed higher with SL nitroglycerin in patients with diabetes (0 vs 30%, p=0.028) or in patients <1.65m height (7.4 vs 25%, p=0.085). Likewise, RAS with SL nitroglycerin seemed more frequent in smokers compared to IA nitroglycerin (0 vs 27%, p=0.089). SL nitroglycerin was not different from IA nitroglycerin in terms of efficiency and safety in overall study population. However it may be inferior to IA nitroglycerin in certain subgroups (shorter individuals, diabetics and smokers). Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Hybrid Approach for Biliary Interventions Employing MRI-Guided Bile Duct Puncture with Near-Real-Time Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wybranski, Christian, E-mail: Christian.Wybranski@uk-koeln.de; Pech, Maciej; Lux, Anke

    ObjectiveTo assess the feasibility of a hybrid approach employing MRI-guided bile duct (BD) puncture for subsequent fluoroscopy-guided biliary interventions in patients with non-dilated (≤3 mm) or dilated BD (≥3 mm) but unfavorable conditions for ultrasonography (US)-guided BD puncture.MethodsA total of 23 hybrid interventions were performed in 21 patients. Visualization of BD and puncture needles (PN) in the interventional MR images was rated on a 5-point Likert scale by two radiologists. Technical success, planning time, BD puncture time and positioning adjustments of the PN as well as technical success of the biliary intervention and complication rate were recorded.ResultsVisualization even of third-order non-dilated BDmore » and PN was rated excellent by both radiologists with good to excellent interrater agreement. MRI-guided BD puncture was successful in all cases. Planning and BD puncture times were 1:36 ± 2.13 (0:16–11:07) min. and 3:58 ± 2:35 (1:11–9:32) min. Positioning adjustments of the PN was necessary in two patients. Repeated capsular puncture was not necessary in any case. All biliary interventions were completed successfully without major complications.ConclusionA hybrid approach which employs MRI-guided BD puncture for subsequent fluoroscopy-guided biliary intervention is feasible in clinical routine and yields high technical success in patients with non-dilated BD and/or unfavorable conditions for US-guided puncture. Excellent visualization of BD and PN in near-real-time interventional MRI allows successful cannulation of the BD.« less

  18. 78 FR 22213 - Airworthiness Directives; Eurocopter France Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-15

    ... float assemblies for any cuts, tears, punctures, or abrasion. Replace the cover if the internal... cuts, tears, punctures, or abrasion. If there is a cut, tear, puncture, or any abrasion, repair the...

  19. Assessment of the SonixGPS system for its application in real-time ultrasonography navigation-guided percutaneous nephrolithotomy for the treatment of complex kidney stones.

    PubMed

    Li, Xiang; Long, Qingzhi; Chen, Xingfa; He, Dalin; He, Hui

    2017-04-01

    SonixGPS is a novel real-time ultrasonography navigation technology, which has been demonstrated to promote accuracy of puncture in surgical operations. The aim of this study is to evaluate its application in guiding the puncture during percutaneous nephrolithotomy (PCNL). We retrospectively reviewed our experience in treating a total of 74 patients with complex kidney stones with PCNL, in which puncture in 37 cases were guided by SonixGPS system, while the other 37 by conventional ultrasound. The effectiveness of operation was evaluated in terms of stone clearance rate, operation time, time to successful puncture, number of attempts for successful puncture and hospital stay. The safety of operation was examined by evaluating postoperative complications. Our retrospective review showed that although there were no significant differences in stone clearance rates between the groups, SonixGPS guidance resulted in more puncture accuracy with shorter puncture time and higher successful puncture rate. Under the help of SonixGPS, most patients (92 %) had no or just mild complications, compared to that (73 %) in conventional ultrasound group. Post-operative decrease of hemoglobin in SonixGPS group was 13.79 (7-33) mg/dl, significantly lower than that 20.97 (8-41) mg/dl in conventional ultrasound group. Our experience demonstrates that SonixGPS is superior to conventional ultrasound in guiding the puncture in PCNL for the treatment of complex kidney stone.

  20. A method for the determination of syringe needle punctures in rubber stoppers using stereoscopic light microscopy.

    PubMed

    Platek, S Frank; Keisler, Mark A; Ranieri, Nicola; Reynolds, Todd W; Crowe, John B

    2002-09-01

    The ability to accurately determine the number of syringe needle penetration holes through the rubber stoppers in pharmaceutical vials and rubber septa in intravenous (i.v.) line and bag ports has been a critical factor in a number of forensic cases involving the thefts of controlled substances or suspected homicide by lethal injection. In the early 1990s, the microscopy and microanalysis group of the U.S. Food and Drug Administration's Forensic Chemistry Center (FCC) developed and implemented a method (unpublished) to locate needle punctures in rubber pharmaceutical vial stoppers. In 1996, as part of a multiple homicide investigation, the Indiana State Police Laboratory (ISPL) contacted the FCC for information on a method to identify and count syringe needle punctures through rubber stoppers in pharmaceutical vials. In a joint project and investigation using the FCC's needle hole location method and applying a method of puncture site mapping developed by the ISPL, a systematic method was developed to locate, identify, count, and map syringe punctures in rubber bottle stoppers or i.v. bag ports using microscopic analysis. The method requires documentation of punctures on both sides of the rubber stoppers and microscopic analysis of each suspect puncture site. The final result of an analysis using the method is a detailed diagram of puncture holes on both sides of a questioned stopper and a record of the minimum number of puncture holes through a stopper.

  1. Puncture mechanics of soft elastomeric membrane with large deformation by rigid cylindrical indenter

    NASA Astrophysics Data System (ADS)

    Liu, Junjie; Chen, Zhe; Liang, Xueya; Huang, Xiaoqiang; Mao, Guoyong; Hong, Wei; Yu, Honghui; Qu, Shaoxing

    2018-03-01

    Soft elastomeric membrane structures are widely used and commonly found in engineering and biological applications. Puncture is one of the primary failure modes of soft elastomeric membrane at large deformation when indented by rigid objects. In order to investigate the puncture failure mechanism of soft elastomeric membrane with large deformation, we study the deformation and puncture failure of silicone rubber membrane that results from the continuous axisymmetric indentation by cylindrical steel indenters experimentally and analytically. In the experiment, effects of indenter size and the friction between the indenter and the membrane on the deformation and puncture failure of the membrane are investigated. In the analytical study, a model within the framework of nonlinear field theory is developed to describe the large local deformation around the punctured area, as well as to predict the puncture failure of the membrane. The deformed membrane is divided into three parts and the friction contact between the membrane and indenter is modeled by Coulomb friction law. The first invariant of the right Cauchy-Green deformation tensor I1 is adopted to predict the puncture failure of the membrane. The experimental and analytical results agree well. This work provides a guideline in designing reliable soft devices featured with membrane structures, which are present in a wide variety of applications.

  2. Primary tracheoesophageal puncture and cricopharyngeal myotomy in stapler-assisted total laryngectomy.

    PubMed

    Beswick, D M; Damrose, E J

    2016-07-01

    To evaluate the utility of the hybrid tracheoesophageal puncture procedure in stapler-assisted laryngectomy. Patients who underwent total laryngectomy at a single institution from 2009 to 2015 were reviewed. The interventions assessed were surgical creation of a tracheoesophageal puncture and placement of a voice prosthesis. The outcomes measured included voicing ability and valve failure. Thirty-nine patients underwent total laryngectomy or pharyngolaryngectomy. Of these, nine underwent stapler-assisted laryngectomy; seven of the nine patients underwent concurrent stapler-assisted laryngectomy, cricopharyngeal myotomy and a hybrid tracheoesophageal puncture procedure. These seven patients were the focus of this review. Successful voicing and oral alimentation was achieved in all patients. Mean time to phonation was 30 days (range, 7-77 days) and mean time to first valve change was 90 days (range, 35-117 days). Primary tracheoesophageal puncture with concurrent voice prosthesis placement and cricopharyngeal myotomy is easily performed with stapler-assisted laryngectomy. The hybrid tracheoesophageal puncture procedure is a simple method that enables a single operator to achieve primary tracheoesophageal puncture and valve placement; in addition, it facilitates concurrent cricopharyngeal myotomy.

  3. Engineering analyses for railroad tank car head puncture resistance

    DOT National Transportation Integrated Search

    2006-11-06

    This paper describes engineering analyses to estimate the : forces, deformations, and puncture resistance of railroad tank : cars. Different approaches to examine puncture of the tank car : head are described. One approach is semi-empirical equations...

  4. Ultrasonographic percutaneous anatomy of the atlanto-occipital region and indirect ultrasound-guided cisternal puncture in the dog and the cat.

    PubMed

    Etienne, A-L; Audigié, F; Peeters, D; Gabriel, A; Busoni, V

    2015-04-01

    Cisternal puncture in dogs and cats is commonly carried out. This article describes the percutaneous ultrasound anatomy of the cisternal region in the dog and the cat and an indirect technique for ultrasound-guided cisternal puncture. Ultrasound images obtained ex vivo and in vivo were compared with anatomic sections and used to identify the landmarks for ultrasound-guided cisternal puncture. The ultrasound-guided procedure was established in cadavers and then applied in vivo in seven dogs and two cats. The anatomic landmarks for the ultrasound-guided puncture are the cisterna magna, the spinal cord, the two occipital condyles on transverse images, the external occipital crest and the dorsal arch of the first cervical vertebra on longitudinal images. Using these ultrasound anatomic landmarks, an indirect ultrasound-guided technique for cisternal puncture is applicable in the dog and the cat. © 2014 Blackwell Verlag GmbH.

  5. A technique for ultrasound-guided blood sampling from a dry and gel-free puncture area.

    PubMed

    Thorn, Sofie; Gopalasingam, Nigopan; Bendtsen, Thomas Fichtner; Knudsen, Lars; Sloth, Erik

    2016-05-07

    Vein punctures are performed daily to sample blood. Ultrasound (US) offers an alternative to the blind landmark technique for difficult vascular access. A challenge for this procedure is the presence of US gel in the puncture area. We present a technique for US-guided puncture from extremity veins not palpable or visible to the human eye, while keeping the puncture area dry and gel-free. Ten healthy volunteers underwent two US-guided vein punctures from veins that were neither palpable nor visible. One was drawn from an antebrachial vein and another from a brachial vein. A sterile barrier drape was made from a commercially available dressing and a piece of transparent sterile plastic. The barrier drape consists of an adhesive part placed on the skin designed for sonography and a free transparent flap constituting the barrier between the unsterile sonographic site and the sterile gel-free puncture site. The success rate for vein puncture was 100% in both locations. A total of 22 skin punctures were performed (11 antebrachial and 11 brachial). Gain output was increased 7% (4-12%), and 8% (4-15%), respectively, to compensate for attenuation of the US signal due to the drape. Alignment of the centre of the transducer with the long-axis of the target vein during the procedure was reported as a challenge. US-guided blood sampling from a brachial and antebrachial vein was possible with a 100% success rate, while ensuring a dry and gel-free venipuncture area on one side and the transducer on the other side of a sterile barrier.

  6. [A new two-chamber model for examination and demonstration of transdural fluid leakage after spinal anesthesia].

    PubMed

    Enk, D; Enk, E

    1995-11-01

    Various in vitro models have been introduced for comparative examinations of post-dural-puncture trauma and measurement of liquor leakage through puncture sites. These models allow simulation of subarachnoid, but not of peridural, pressure. A new two-chamber-model realizes the simulation of both subarachnoid and peridural pressure and allows observation of in vitro punctures with video-documentation. Frame grabbing and (computer-aided) image analysis show new aspects of spinal puncture effects. Therefore, post-dural-puncture trauma and retraction can be objectively visualized by this method, which has not previously been demonstrated. Two-chamber-model consists of two short aluminium cylinders. Native human dura patches (8X8 mm) from fresh cadavers are put (correctly oriented) between two special polyamide seals. Mounted between the upper and lower cylinder, these seals stretch the dura patch, which remains flexible and even in all directions. After filling of the lower (subarachnoid) and upper (peridural) chamber with Ringer lactate solution, positive or negative physiological pressure can be adjusted by way of two (Ringer lactate solution filled) infusion lines in each chamber. Puncturing is performed at an angle of 57 degrees to the dura. The model allows examination with epi-illumination and transmitted (polarized) light. In vitro punctures are observed through an inverted camera lens with an CCD-Hi8 video camera (Canon UC1HI) looking into the peridural chamber and documented by means of an S-VHS video recorder (Panasonic NV-FS200EG). After true-colour frame grabbing by a video digitizer (Fast Screen Machine II), single video frames can be optimized and analysed with a 486-66 MHz computer and conventional software (Corel Draw 3.0, Photostyler 1.1a, DDL Aequitas 1.00b). Punctures demonstrated in this paper have been done under simulation of a transdural gradient of 20 cm water similar to the situation of a recumbent patient (15 cm water in the subarachnoid and -5 cm water in the peridural chamber). The punctures were followed by short-time observation for up to 10 minutes. By making it possible to obtains a picture of the puncture site at 20-ms intervals (because of the PAL norm of 50 half-frames/s), video-documentation has become accepted as superior to conventional photography. When the Ringer lactate solution in the subarachnoid chamber is stained with methylene blue, transdural leakage can easily be observed. The result of this documentation technique demonstrate that not dural puncture can be atraumatic, when a 29-G Quincke needle is used. Calculation on the difference between a digitized video frame before and after the puncture clearly illustrates the dural trauma. Owing to their non-cutting tip, as expected, pencil-point needles leave diffuse changes across the dura patch, whereas a more local trauma was observed after puncturing with cutting-tip needles. The same computer calculation between two video frames allows examination of post-puncture-dural retraction of the puncture site. In this connection, we found that relevant dural retraction is a phenomenon limited to the first minute after puncture. Thin spinal needles with so-called modern tips (e.g. Whitacre, Atraucan) can minimize the post-dural-puncture trauma, whereas thicker, conventional, spinal needles (Quincke) leave considerable dural defects. The two-chamber-model presented allows easy simulation of physiological subarachnoid and peridural pressure. The Ringer lactate solution in the subarachnoid chamber corresponds to the liquor, whereas that in the peridural chamber corresponds to the intercellular (peridural) space. The tension of the dural patch between the polyamide seals is similar to the situation in an anotomical model observed by spinaloscopy (in an earlier study). With the video documentation and computer-aided analysis technique introduced, dural trauma and retraction of the puncture site can be examined and demo

  7. Point of impact: the effect of size and speed on puncture mechanics.

    PubMed

    Anderson, P S L; LaCosse, J; Pankow, M

    2016-06-06

    The use of high-speed puncture mechanics for prey capture has been documented across a wide range of organisms, including vertebrates, arthropods, molluscs and cnidarians. These examples span four phyla and seven orders of magnitude difference in size. The commonality of these puncture systems offers an opportunity to explore how organisms at different scales and with different materials, morphologies and kinematics perform the same basic function. However, there is currently no framework for combining kinematic performance with cutting mechanics in biological puncture systems. Our aim here is to establish this framework by examining the effects of size and velocity in a series of controlled ballistic puncture experiments. Arrows of identical shape but varying in mass and speed were shot into cubes of ballistic gelatine. Results from high-speed videography show that projectile velocity can alter how the target gel responds to cutting. Mixed models comparing kinematic variables and puncture patterns indicate that the kinetic energy of a projectile is a better predictor of penetration than either momentum or velocity. These results form a foundation for studying the effects of impact on biological puncture, opening the door for future work to explore the influence of morphology and material organization on high-speed cutting dynamics.

  8. Comparison of Sprotte and Quincke needles with respect to post dural puncture headache and backache.

    PubMed

    Tarkkila, P J; Heine, H; Tervo, R R

    1992-01-01

    The objective of this study was to compare 24-gauge Sprotte and 25-gauge Quincke needles with respect to post dural puncture headache and backache. Three hundred ASA Physical Status I or II patients scheduled for minor orthopedic or urologic operations under spinal anesthesia were chosen for this randomized, prospective study at a university hospital and a city hospital. Anesthetic technique, intravenous fluids, and postoperative pain therapy were standardized. Patients were randomly divided into three equal groups. Spinal anesthesia was performed with either a 24-gauge Sprotte needle or a 25-gauge Quincke needle with the cutting bevel parallel or perpendicular to the dural fibers. Anesthesia could not be performed in three cases with the Sprotte needle and in one case with the Quincke needle. The most common complications were post dural puncture backache (18.0%), post dural puncture headache (8.2%), and non-postural headache (6.7%). No major complications occurred. The Quincke needle with bevel perpendicular to the dural fibers caused a 17.9% incidence of post dural puncture headache. The Quincke with bevel parallel to the dural fibers and the Sprotte needles caused similar post dural puncture headache rates (4.5% and 2.4%, respectively). Other factors associated with post dural puncture headache were young age, early ambulation, and sedation during spinal anesthesia. There were no significant differences between needles in the incidence of post dural puncture backache. Our data indicate that Quincke needles should not be used with the needle bevel inserted perpendicular to the dural fibers. The Sprotte needle does not solve the problem of post dural puncture headache and backache.

  9. Influence of Medial Collateral Ligament Release for Internal Rotation of Tibia in Posterior-Stabilized Total Knee Arthroplasty: A Cadaveric Study.

    PubMed

    Wada, Keizo; Hamada, Daisuke; Tamaki, Shunsuke; Higashino, Kosaku; Fukui, Yoshihiro; Sairyo, Koichi

    2017-01-01

    Previous studies suggested that changes in kinematics in total knee arthroplasty (TKA) affected satisfaction level. The aim of this cadaveric study was to evaluate the effect of medial collateral ligament (MCL) release by multiple needle puncture on knee rotational kinematics in posterior-stabilized TKA. Six fresh, frozen cadaveric knees were included in this study. All TKA procedures were performed with an image-free navigation system using a 10-mm polyethylene insert. Tibial internal rotation was assessed to evaluate intraoperative knee kinematics. Multiple needle puncturing was performed 5, 10, and 15 times for the hard portion of the MCL at 90° knee flexion. Kinematic analysis was performed after every 5 punctures. After performing 15 punctures, a 14-mm polyethylene insert was inserted, and kinematic analysis was performed. The tibial internal rotation angle at maximum knee flexion without multiple needle puncturing was significantly larger (9.42°) than that after 15 punctures (3°). Negative correlation (Pearson r = -0.715, P < .001) between tibial internal rotation angle at maximum knee flexion and frequency of puncture was observed. The tibial internal rotation angle with a 14-mm insert was significantly larger (7.25°) compared with the angle after 15 punctures. Tibial internal rotation during knee flexion was reduced by extensive MCL release using multiple needle puncturing and was recovered by increasing of medial tightness. From the point of view of knee kinematics, medial tightness should be allowed to maintain the internal rotation angle of the tibia during knee flexion which might lead to patient satisfaction. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Incidence and management of inadvertent puncture and sheath placement in the aorta during attempted transseptal puncture.

    PubMed

    Wasmer, Kristina; Zellerhoff, Stephan; Köbe, Julia; Mönnig, Gerold; Pott, Christian; Dechering, Dirk G; Lange, Philipp S; Frommeyer, Gerrit; Eckardt, Lars

    2017-03-01

    Transseptal punctures (TSP) are routinely performed in cardiac interventions requiring access to the left heart. While pericardial effusion/tamponade are well-recognized complications, few data exist on accidental puncture of the aorta and its management and outcome. We therefore analysed our single centre database for this complication. We assessed frequency and outcome of inadvertent aortic puncture during TSP in consecutive patients undergoing ablation procedures between January 2005 and December 2014. During the 10-year period, two inadvertent aortic punctures occurred among 2936 consecutive patients undergoing 4305 TSP (0.07% of patients, 0.05% of TSP) and in one Mustard patient during attempted baffle puncture. The first two patients required left ventricular access for catheter ablation of ventricular tachycardia. In both cases, an 11.5F steerable sheath (inner diameter 8.5F) was accidentally placed in the ascending aorta just above the aortic valve. In the presence of surgical standby, the sheaths were pulled back with a wire left in the aorta. Under careful haemodynamic and echocardiographic observation, this wire was also pulled back 30 min later. None of the patients required a closing device or open heart surgery. None of the patients suffered complications from the accidental aortic puncture and sheath placement. Inadvertent aortic puncture and sheath placement are rare complications in patients undergoing TSP for interventional procedures. Leaving a guidewire in place during the observation period may allow introduction of sheaths or other tools in order to control haemodynamic deterioration. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  11. Suitability of Exoseal Vascular Closure Device for Antegrade Femoral Artery Puncture Site Closure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmelter, Christopher, E-mail: christopher.schmelter@klinikum-ingolstadt.de; Liebl, Andrea; Poullos, Nektarios

    Purpose. To assess the efficacy and safety of the Exoseal vascular closure device for antegrade puncture of the femoral artery. Methods. In a prospective study from February 2011 to January 2012, a total of 93 consecutive patients received a total of 100 interventional procedures via an antegrade puncture of the femoral artery. An Exoseal vascular closure device (6F) was used for closure in all cases. Puncture technique, duration of manual compression, and use of compression bandages were documented. All patients were monitored by vascular ultrasound and color-coded duplex sonography of their respective femoral artery puncture site within 12 to 36more » h after angiography to check for vascular complications. Results. In 100 antegrade interventional procedures, the Exoseal vascular closure device was applied successfully for closure of the femoral artery puncture site in 96 cases (96 of 100, 96.0 %). The vascular closure device could not be deployed in one case as a result of kinking of the vascular sheath introducer and in three cases because the bioabsorbable plug was not properly delivered to the extravascular space adjacent to the arterial puncture site, but instead fully removed with the delivery system (4.0 %). Twelve to 36 h after the procedure, vascular ultrasound revealed no complications at the femoral artery puncture site in 93 cases (93.0 %). Minor vascular complications were found in seven cases (7.0 %), with four cases (4.0 %) of pseudoaneurysm and three cases (3.0 %) of significant late bleeding, none of which required surgery. Conclusion. The Exoseal vascular closure device was safely used for antegrade puncture of the femoral artery, with a high rate of procedural success (96.0 %), a low rate of minor vascular complications (7.0 %), and no major adverse events.« less

  12. A New Navigation System of Renal Puncture for Endoscopic Combined Intrarenal Surgery: Real-time Virtual Sonography-guided Renal Access.

    PubMed

    Hamamoto, Shuzo; Unno, Rei; Taguchi, Kazumi; Ando, Ryosuke; Hamakawa, Takashi; Naiki, Taku; Okada, Shinsuke; Inoue, Takaaki; Okada, Atsushi; Kohri, Kenjiro; Yasui, Takahiro

    2017-11-01

    To evaluate the clinical utility of a new navigation technique for percutaneous renal puncture using real-time virtual sonography (RVS) during endoscopic combined intrarenal surgery. Thirty consecutive patients who underwent endoscopic combined intrarenal surgery for renal calculi, between April 2014 and July 2015, were divided into the RVS-guided puncture (RVS; n = 15) group and the ultrasonography-guided puncture (US; n = 15) group. In the RVS group, renal puncture was repeated until precise piercing of a papilla was achieved under direct endoscopic vision, using the RVS system to synchronize the real-time US image with the preoperative computed tomography image. In the US group, renal puncture was performed under US guidance only. In both groups, 2 urologists worked simultaneously to fragment the renal calculi after inserting the miniature percutaneous tract. The mean sizes of the renal calculi in the RVS and the US group were 33.5 and 30.5 mm, respectively. A lower mean number of puncture attempts until renal access through the calyx was needed for the RVS compared with the US group (1.6 vs 3.4 times, respectively; P = .001). The RVS group had a lower mean postoperative hemoglobin decrease (0.93 vs 1.39 g/dL, respectively; P = .04), but with no between-group differences with regard to operative time, tubeless rate, and stone-free rate. None of the patients in the RVS group experienced postoperative complications of a Clavien score ≥2, with 3 patients experiencing such complications in the US group. RVS-guided renal puncture was effective, with a lower incidence of bleeding-related complications compared with US-guided puncture. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Usefulness of real-time three-dimensional ultrasonography in percutaneous nephrostomy: an animal study.

    PubMed

    Hongzhang, Hong; Xiaojuan, Qin; Shengwei, Zhang; Feixiang, Xiang; Yujie, Xu; Haibing, Xiao; Gallina, Kazobinka; Wen, Ju; Fuqing, Zeng; Xiaoping, Zhang; Mingyue, Ding; Huageng, Liang; Xuming, Zhang

    2018-05-17

    To evaluate the effect of real-time three-dimensional (3D) ultrasonography (US) in guiding percutaneous nephrostomy (PCN). A hydronephrosis model was devised in which the ureters of 16 beagles were obstructed. The beagles were divided equally into groups 1 and 2. In group 1, the PCN was performed using real-time 3D US guidance, while in group 2 the PCN was guided using two-dimensional (2D) US. Visualization of the needle tract, length of puncture time and number of puncture times were recorded for the two groups. In group 1, score for visualization of the needle tract, length of puncture time and number of puncture times were 3, 7.3 ± 3.1 s and one time, respectively. In group 2, the respective results were 1.4 ± 0.5, 21.4 ± 5.8 s and 2.1 ± 0.6 times. The visualization of needle tract in group 1 was superior to that in group 2, and length of puncture time and number of puncture times were both lower in group 1 than in group 2. Real-time 3D US-guided PCN is superior to 2D US-guided PCN in terms of visualization of needle tract and the targeted pelvicalyceal system, leading to quick puncture. Real-time 3D US-guided puncture of the kidney holds great promise for clinical implementation in PCN. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.

  14. The Explorer XVI Micrometeoroid Satellite Description and Preliminary Results for the Period December 16, 1962 Through January 13, 1963

    NASA Technical Reports Server (NTRS)

    Hastings, E. C., Jr.

    1963-01-01

    Explorer XVI (1962 Beta Chi l) data that have been analyzed for the period between December 16, 1962 (launch date), and January 13, 1963, indicate that the orbit achieved was close to the predicted orbit. Ten punctures of annealed 0.001-inch-thick beryllium-copper have been used to determine a puncture rate of 0.035 per square foot per day in this material. One puncture of a 0.002-inch-thick sample has also occurred in this period. A tentative evaluation of the puncture rate for the 0.001-inch beryllium-copper in terms of the rate for an equivalent thickness of aluminum has been attempted, and the result has been compared with two different puncture rate estimates. The three micrometeoroid impact detecting systems are operating. Counting rates for the high- and low-sensitivity systems were close to anticipated values near the end of one week. Two of the 0.001-inch-steel-covered grid detectors have been punctured, but none of the 0.003- or 0.006-inch-steel-covered grid detectors have indicated punctures. One of the cadmium sulfide cells indicates three punctures of the 0.00025-inch Mylar cover. None of the 0.002- or 0.003-inch-copper-wire cards have indicated a break in the period covered. Telemetry temperatures were initially higher than expected although they remained well within operating limits. Sensor temperatures have remained within the expected bounds.

  15. Cross-Layer Design for Robust and Scalable Video Transmission in Dynamic Wireless Environment

    DTIC Science & Technology

    2011-02-01

    code rate convolutional codes or prioritized Rate - Compatible Punctured ...34New rate - compatible punctured convolutional codes for Viterbi decoding," IEEE Trans. Communications, Volume 42, Issue 12, pp. 3073-3079, Dec...Quality of service RCPC Rate - compatible and punctured convolutional codes SNR Signal to noise

  16. Evaluation of semi-empirical analyses for railroad tank car puncture velocity, part 2 : correlations with engineering analysis

    DOT National Transportation Integrated Search

    2001-11-01

    This report is the second in a series focusing on methods to determine the puncture velocity of railroad tank car shells. In this : context, puncture velocity refers to the impact velocity at which a coupler will completely pierce the shell and punct...

  17. Diagnostic Lumbar Puncture

    PubMed Central

    Doherty, Carolynne M; Forbes, Raeburn B

    2014-01-01

    Diagnostic Lumbar Puncture is one of the most commonly performed invasive tests in clinical medicine. Evaluation of an acute headache and investigation of inflammatory or infectious disease of the nervous system are the most common indications. Serious complications are rare, and correct technique will minimise diagnostic error and maximise patient comfort. We review the technique of diagnostic Lumbar Puncture including anatomy, needle selection, needle insertion, measurement of opening pressure, Cerebrospinal Fluid (CSF) specimen handling and after care. We also make some quality improvement suggestions for those designing services incorporating diagnostic Lumbar Puncture. PMID:25075138

  18. Point of impact: the effect of size and speed on puncture mechanics

    PubMed Central

    Anderson, P. S. L.; LaCosse, J.; Pankow, M.

    2016-01-01

    The use of high-speed puncture mechanics for prey capture has been documented across a wide range of organisms, including vertebrates, arthropods, molluscs and cnidarians. These examples span four phyla and seven orders of magnitude difference in size. The commonality of these puncture systems offers an opportunity to explore how organisms at different scales and with different materials, morphologies and kinematics perform the same basic function. However, there is currently no framework for combining kinematic performance with cutting mechanics in biological puncture systems. Our aim here is to establish this framework by examining the effects of size and velocity in a series of controlled ballistic puncture experiments. Arrows of identical shape but varying in mass and speed were shot into cubes of ballistic gelatine. Results from high-speed videography show that projectile velocity can alter how the target gel responds to cutting. Mixed models comparing kinematic variables and puncture patterns indicate that the kinetic energy of a projectile is a better predictor of penetration than either momentum or velocity. These results form a foundation for studying the effects of impact on biological puncture, opening the door for future work to explore the influence of morphology and material organization on high-speed cutting dynamics. PMID:27274801

  19. Post spinal puncture headache, an old problem and new concepts: review of articles about predisposing factors

    PubMed Central

    Jabbari, Ali; Alijanpour, Ebrahim; Mir, Mehrafza; Bani hashem, Nadia; Rabiea, Seyed Mozaffar; Rupani, Mohammad Ali

    2013-01-01

    Post spinal puncture headache (PSPH) is a well known complication of spinal anesthesia. It occurs after spinal anesthesia induction due to dural and arachnoid puncture and has a significant effect on the patient’s postoperative well being. This manuscript is based on an observational study that runs on Babol University of Medical Sciences and review of literatures about current concepts about the incidence, risk factors and predisposing factors of post spinal puncture headache. The overall incidence of post-dural puncture headache after intentional dural puncture varies form 0.1-36%, while it is about 3.1% by atraumatic spinal needle 25G Whitacre. 25G Quincke needle with a medium bevel cutting is popular with widespread use and the incidence of PSPH is about 25%, but its incidence obtained 17.3% by spinal needle 25G Quincke in our observation. The association of predisposing factors like female, young age, pregnancy, low body mass index, multiple dural puncture, inexpert operators and past medical history of chronic headache, expose the patient to PSPH. The identification of factors that predict the likelihood of PSPH is important so that measures can be taken to minimize this painful complication resulting from spinal anesthesia. PMID:24009943

  20. Reliability and performance of innovative surgical double-glove hole puncture indication systems.

    PubMed

    Edlich, Richard F; Wind, Tyler C; Heather, Cynthia L; Thacker, John G

    2003-01-01

    During operative procedures, operating room personnel wear sterile surgical gloves designed to protect them and their patients against transmissible infections. The Food and Drug Administration (FDA) has set compliance policy guides for manufacturers of gloves. The FDA allows surgeons' gloves whose leakage defect rates do not exceed 1.5 acceptable quality level (AQL) to be used in operating rooms. The implications of this policy are potentially enormous to operating room personnel and patients. This unacceptable risk to the personnel and patient could be significantly reduced by the use of sterile double surgical gloves. Because double-gloves are also susceptible to needle puncture, a double-glove hole indication system is urgently needed to immediately detect surgical needle glove punctures. This warning would allow surgeons to remove the double-gloves, wash their hands, and then don a sterile set of double-gloves with an indication system. During the last decade, Regent Medical has devised non-latex and latex double-glove hole puncture indication systems. The purpose of this comprehensive study is to detect the accuracy of the non-latex and latex double-glove hole puncture indication systems using five commonly used sterile surgical needles: the taper point surgical needle, tapercut surgical needle, reverse cutting edge surgical needle, taper cardiopoint surgical needle, and spatula surgical needle. After subjecting both the non-latex and latex double-glove hole puncture indication systems to surgical needle puncture in each glove fingertip, these double-glove systems were immersed in a sterile basin of saline, after which the double-gloved hands manipulated surgical instruments. Within two minutes, both the non-latex and latex hole puncture indication systems accurately detected needle punctures in all of the surgical gloves, regardless of the dimensions of the surgical needles. In addition, the size of the color change visualized through the translucent outer glove did not correlate with needle diameter. On the basis of this extensive experimental evaluation, both the non-latex and latex double-glove hole puncture indication systems should be used in all operative procedures by all operating room personnel.

  1. In vitro fenestration of aortic stent-grafts: implications of puncture methods for in situ fenestration durability.

    PubMed

    Riga, Celia V; Bicknell, Colin D; Basra, Melvinder; Hamady, Mohamad; Cheshire, Nicholas J W

    2013-08-01

    To investigate the quality of stent-graft fenestrations created in vitro using different needle puncture and balloon dilation angles in different commercial endografts. Fenestrations were made in a standardized fashion in 3 different endograft types: Talent monofilament twill woven polyester, Zenith multifilament tubular woven polyester, and Endofit thin-walled expanded polytetrafluoroethylene (PTFE). Punctures were made at 30°, 60°, and 90° angles using a 20-G needle and dilated using 6-mm standard and 7-mm cutting balloons; at least 6 fenestrations were made at each angle with standard balloons and at least 6 with cutting balloons. The 137 fenestrations were examined under light microscopy; quantitative and qualitative digital image analysis was performed to determine size, shape, and fenestration quality. PTFE grafts were easier to puncture/dilate, resulting in larger, elliptical fenestrations with overall better quality than the Dacron grafts; however, the puncture/dilation angle made an impact on the shape and quality of fenestrations. A significant number of fabric tears were observed in PTFE fabric at <90° puncture/dilation angles compared to Dacron grafts. In Dacron grafts, fenestration quality was significantly higher with 90° puncture/dilation angles (higher in Talent grafts). Cutting balloon use resulted in significantly more fabric tears and poor quality fenestrations in all graft types. Different endografts behave significantly differently when fenestrations are fashioned. Optimum puncture/dilation is important when considering in vivo fenestration techniques. Improvements in instrumentation, materials, and techniques are required to make this a reliable and reproducible endovascular option.

  2. [Assessment of amylase and lipase levels following puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions].

    PubMed

    Membrillo-Romero, Alejandro; Gonzalez-Lanzagorta, Rubén; Rascón-Martínez, Dulce María

    Puncture biopsy and fine needle aspiration guided by endoscopic ultrasound has been used as an effective technique and is quickly becoming the procedure of choice for diagnosis and staging in patients suspected of having pancreatic cancer. This procedure has replaced retrograde cholangiopancreatography and brush cytology due to its higher sensitivity for diagnosis, and lower risk of complications. To assess the levels of pancreatic enzymes amylase and lipase, after the puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions and the frequency of post-puncture acute pancreatitis. A longitudinal and descriptive study of consecutive cases was performed on outpatients submitted to puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions. Levels of pancreatic enzymes such as amylase and lipase were measured before and after the pancreatic puncture. Finally we documented post-puncture pancreatitis cases. A total of 100 patients who had been diagnosed with solid and cystic lesions were included in the study. Significant elevation was found at twice the reference value for lipase in 5 cases (5%) and for amylase in 2 cases (2%), none had clinical symptoms of acute pancreatitis. Eight (8%) of patients presented with mild nonspecific pain with no enzyme elevation compatible with pancreatitis. Pancreatic biopsy needle aspiration guided by endoscopic ultrasound was associated with a low rate of elevated pancreatic enzymes and there were no cases of post-puncture pancreatitis. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  3. Design of Intelligent Cross-Layer Routing Protocols for Airborne Wireless Networks Under Dynamic Spectrum Access Paradigm

    DTIC Science & Technology

    2011-05-01

    rate convolutional codes or the prioritized Rate - Compatible Punctured ...Quality of service RCPC Rate - compatible and punctured convolutional codes SNR Signal to noise ratio SSIM... Convolutional (RCPC) codes . The RCPC codes achieve UEP by puncturing off different amounts of coded bits of the parent code . The

  4. 16 CFR 1500.18 - Banned toys and other banned articles intended for use by children.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., or loose small objects that have the potential for causing lacerations, puncture wound injury... deliberately removed by a child, which toy has the potential for causing laceration, puncture wound injury... external components that have the potential for causing laceration, puncture wound injury, or other similar...

  5. Technological advances and changing indications for lumbar puncture in neurological disorders.

    PubMed

    Costerus, Joost M; Brouwer, Matthijs C; van de Beek, Diederik

    2018-03-01

    Technological advances have changed the indications for and the way in which lumbar puncture is done. Suspected CNS infection remains the most common indication for lumbar puncture, but new molecular techniques have broadened CSF analysis indications, such as the determination of neuronal autoantibodies in autoimmune encephalitis. New screening techniques have increased sensitvity for pathogen detection and can be used to identify pathogens that were previously unknown to cause CNS infections. Evidence suggests that potential treatments for neurodegenerative diseases, such as Alzheimer's disease, will rely on early detection of the disease with the use of CSF biomarkers. In addition to being used as a diagnostic tool, lumbar puncture can also be used to administer intrathecal treatments as shown by studies of antisense oligonucleotides in patients with spinal muscular atrophy. Lumbar puncture is generally a safe procedure but complications can occur, ranging from minor (eg, back pain) to potentially devastating (eg, cerebral herniation). Evidence that an atraumatic needle tip design reduces complications of lumbar puncture is compelling, and reinforces the need to change clinical practice. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Noninvasive Assessment of Intracranial Pressure Status in Idiopathic Intracranial Hypertension Using Displacement Encoding with Stimulated Echoes (DENSE) MRI: A Prospective Patient Study with Contemporaneous CSF Pressure Correlation.

    PubMed

    Saindane, A M; Qiu, D; Oshinski, J N; Newman, N J; Biousse, V; Bruce, B B; Holbrook, J F; Dale, B M; Zhong, X

    2018-02-01

    Intracranial pressure is estimated invasively by using lumbar puncture with CSF opening pressure measurement. This study evaluated displacement encoding with stimulated echoes (DENSE), an MR imaging technique highly sensitive to brain motion, as a noninvasive means of assessing intracranial pressure status. Nine patients with suspected elevated intracranial pressure and 9 healthy control subjects were included in this prospective study. Controls underwent DENSE MR imaging through the midsagittal brain. Patients underwent DENSE MR imaging followed immediately by lumbar puncture with opening pressure measurement, CSF removal, closing pressure measurement, and immediate repeat DENSE MR imaging. Phase-reconstructed images were processed producing displacement maps, and pontine displacement was calculated. Patient data were analyzed to determine the effects of measured pressure on pontine displacement. Patient and control data were analyzed to assess the effects of clinical status (pre-lumbar puncture, post-lumbar puncture, or control) on pontine displacement. Patients demonstrated imaging findings suggesting chronically elevated intracranial pressure, whereas healthy control volunteers demonstrated no imaging abnormalities. All patients had elevated opening pressure (median, 36.0 cm water), decreased by the removal of CSF to a median closing pressure of 17.0 cm water. Patients pre-lumbar puncture had significantly smaller pontine displacement than they did post-lumbar puncture after CSF pressure reduction ( P = .001) and compared with controls ( P = .01). Post-lumbar puncture patients had statistically similar pontine displacements to controls. Measured CSF pressure in patients pre- and post-lumbar puncture correlated significantly with pontine displacement ( r = 0.49; P = .04). This study establishes a relationship between pontine displacement from DENSE MR imaging and measured pressure obtained contemporaneously by lumbar puncture, providing a method to noninvasively assess intracranial pressure status in idiopathic intracranial hypertension. © 2018 by American Journal of Neuroradiology.

  7. Clinical value of a self-designed training model for pinpointing and puncturing trigeminal ganglion.

    PubMed

    He, Yu-Quan; He, Shu; Shen, Yun-Xia; Qian, Cheng

    2014-04-01

    OBJECTIVES. A training model was designed for learners and young physicians to polish their skills in clinical practices of pinpointing and puncturing trigeminal ganglion. METHODS. A head model, on both cheeks of which the deep soft tissue was replaced by stuffed organosilicone and sponge while the superficial soft tissue, skin and the trigeminal ganglion were made of organic silicon rubber for an appearance of real human being, was made from a dried skull specimen and epoxy resin. Two physicians who had experiences in puncturing foramen ovale and trigeminal ganglion were selected to test the model, mainly for its appearance, X-ray permeability, handling of the puncture, and closure of the puncture sites. Four inexperienced physicians were selected afterwards to be trained combining Hartel's anterior facial approach with the new method of real-time observation on foramen ovale studied by us. RESULTS. Both appearance and texture of the model were extremely close to those of a real human. The fact that the skin, superficial soft tissue, deep muscles of the cheeks, and the trigeminal ganglion made of organic silicon rubber all had great elasticity resulted in quick closure and sealing of the puncture sites. The head model made of epoxy resin had similar X-ray permeability to a human skull specimen under fluoroscopy. The soft tissue was made of radiolucent material so that the training can be conducted with X-ray guidance. After repeated training, all the four young physicians were able to smoothly and successfully accomplish the puncture. CONCLUSION. This self-made model can substitute for cadaver specimen in training learners and young physicians on foramen ovale and trigeminal ganglion puncture. It is very helpful for fast learning and mastering this interventional operation skill, and the puncture accuracy can be improved significantly with our new method of real-time observation on foramen ovale.

  8. Accidental dural puncture, postdural puncture headache, intrathecal catheters, and epidural blood patch: revisiting the old nemesis.

    PubMed

    Kaddoum, Roland; Motlani, Faisal; Kaddoum, Romeo N; Srirajakalidindi, Arvi; Gupta, Deepak; Soskin, Vitaly

    2014-08-01

    One of the controversial management options for accidental dural puncture in pregnant patients is the conversion of labor epidural analgesia to continuous spinal analgesia by threading the epidural catheter intrathecally. No clear consensus exists on how to best prevent severe headache from occurring after accidental dural puncture. To investigate whether the intrathecal placement of an epidural catheter following accidental dural puncture impacts the incidence of postdural puncture headache (PDPH) and the subsequent need for an epidural blood patch in parturients. A retrospective chart review of accidental dural puncture was performed at Hutzel Women's Hospital in Detroit, MI, USA for the years 2002-2010. Documented cases of accidental dural punctures (N = 238) were distributed into two groups based on their management: an intrathecal catheter (ITC) group in which the epidural catheter was inserted intrathecally and a non-intrathecal catheter (non-ITC) group that received the epidural catheter inserted at different levels of lumbar interspaces. The incidence of PDPH as well as the necessity for epidural blood patch was analyzed using two-tailed Fisher's exact test. In the non-ITC group, 99 (54 %) parturients developed PDPH in comparison to 20 (37 %) in the ITC [odds ratio (OR), 1.98; 95 % confidence interval (CI), 1.06-3.69; P = 0.03]. Fifty-seven (31 %) of 182 patients in the non-ITC group required an epidural blood patch (EBP) (data for 2 patients of 184 were missing). In contrast, 7 (13 %) of parturients in the ITC group required an EBP. The incidence of EBP was calculated in parturients who actually developed headache to be 57 of 99 (57 %) in the non-ITC group versus 7 of 20 (35 %) in the ITC group (OR, 2.52; 95 % CI, 0.92-6.68; P = 0.07). The insertion of an intrathecal catheter following accidental dural puncture decreases the incidence of PDPH but not the need for epidural blood patch in parturients.

  9. Arterial puncture using insulin needle is less painful than with standard needle: a randomized crossover study.

    PubMed

    Ibrahim, Irwani; Yau, Ying Wei; Ong, Lizhen; Chan, Yiong Huak; Kuan, Win Sen

    2015-03-01

    Arterial punctures are important procedures performed by emergency physicians in the assessment of ill patients. However, arterial punctures are painful and can create anxiety and needle phobia in patients. The pain score of radial arterial punctures were compared between the insulin needle and the standard 23-gauge hypodermic needle. In a randomized controlled crossover design, healthy volunteers were recruited to undergo bilateral radial arterial punctures. They were assigned to receive either the insulin or the standard needle as the first puncture, using blocked randomization. The primary outcome was the pain score measured on a 100-mm visual analogue scale (VAS) for pain, and secondary outcomes were rate of hemolysis, mean potassium values, and procedural complications immediately and 24 hours postprocedure. Fifty healthy volunteers were included in the study. The mean (±standard deviation) VAS score in punctures with the insulin needle was lower than the standard needle (23 ± 22 mm vs. 39 ± 24 mm; mean difference = -15 mm; 95% confidence interval = -22 mm to -7 mm; p < 0.001). The rates of hemolysis and mean potassium value were greater in samples obtained using the insulin needle compared to the standard needle (31.3% vs. 11.6%, p = 0.035; and 4.6 ±0.7 mmol/L vs. 4.2 ±0.5 mmol/L, p = 0.002). Procedural complications were lower in punctures with the insulin needle both immediately postprocedure (0% vs. 24%; p < 0.001) and at 24 hours postprocedure (5.4% vs. 34.2%; p = 0.007). Arterial punctures using insulin needles cause less pain and fewer procedural complications compared to standard needles. However, due to the higher rate of hemolysis, its use should be limited to conditions that do not require a concurrent potassium value in the same blood sample. © 2015 by the Society for Academic Emergency Medicine.

  10. Influence of transvaginal ultrasound-guided follicular punctures in the mare on heart rate, respiratory rate, facial expression changes, and salivary cortisol as pain scoring.

    PubMed

    Diego, Rodrigo; Douet, Cécile; Reigner, Fabrice; Blard, Thierry; Cognié, Juliette; Deleuze, Stefan; Goudet, Ghylène

    2016-10-15

    Transvaginal ultrasound-guided follicular punctures are widely used in the mare for diagnosis, research, and commercial applications. The objective of our study was to determine their influence on pain, stress, and well-being in the mare, by evaluating heart rate, breath rate, facial expression changes, and salivary cortisol before, during, and after puncture. For this experiment, 21 pony mares were used. Transvaginal ultrasound-guided aspirations were performed on 11 mares. After injections for sedation, analgesia, and antispasmodia, the follicles from both ovaries were aspirated with a needle introduced through the vagina wall into the ovary. In the control group, 10 mares underwent similar treatments and injections, but no follicular aspiration. Along the session, heart rate and breath rate were evaluated by a trained veterinarian, ears position, eyelid closure, and contraction of facial muscles were evaluated, and salivary samples were taken for evaluation of cortisol concentration. A significant relaxation was observed after sedative injection in the punctured and control mares, according to ear position, eyelid closure, and contraction of facial muscles, but no difference between punctured and control animals was recorded. No significant modification of salivary cortisol concentration during puncture and no difference between punctured and control mares at any time were observed. No significant modification of the breath rate was observed along the procedure for the punctured and the control mares. Heart rate increased significantly but transiently when the needle was introduced in the ovary and was significantly higher at that time for the punctured mares than that for control mares. None of the other investigated parameters were affected at that time, suggesting discomfort is minimal and transient. Improving analgesia, e.g., through a multimodal approach, during that possibly more sensitive step could be recommended. The evaluation of facial expression changes and heart rate is easy-to-use and accurate tools to evaluate pain and well-being of the mare. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Percutaneous Direct Puncture Embolization with N-butyl-cyanoacrylate for High-flow Priapism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tokue, Hiroyuki, E-mail: tokue@s2.dion.ne.jp; Shibuya, Kei; Ueno, Hiroyuki

    There are many treatment options in high-flow priapism. Those mentioned most often are watchful waiting, Doppler-guided compression, endovascular highly selective embolization, and surgery. We present a case of high-flow priapism in a 57-year-old man treated by percutaneous direct puncture embolization of a post-traumatic left cavernosal arteriovenous fistula using N-butyl-cyanoacrylate. Erectile function was preserved during a 12-month follow-up. No patients with percutaneous direct puncture embolization for high-flow priapism have been reported previously. Percutaneous direct puncture embolization is a potentially useful and safe method for management of high-flow priapism.

  12. Comparing the Effect of 3 Kinds of Different Materials on the Hemostasis of the Central Venous Catheter

    NASA Astrophysics Data System (ADS)

    Li, Yan-Ming; Liang, Zhen-Zhen; Song, Chun-Lei

    2016-05-01

    To compare the effect of 3 kinds of different materials on the hemostasis of puncture site after central venous catheterization. Method: A selection of 120 patients with peripheral central venous catheter chemotherapy in the Affiliated Hospital of our university from January 2014 to April 2015, Randomly divided into 3 groups, using the same specification (3.5cm × 2cm) alginate gelatin sponge and gauze dressing, 3 kinds of material compression puncture point, 3 groups of patients after puncture 24 h within the puncture point of local blood and the catheter after the catheter 72 h within the catheter maintenance costs. Result: (1) The local infiltration of the puncture point in the 24 h tube: The use of alginate dressing and gelatin sponge hemostatic effect is better than that of compression gauze. The difference was statistically significant (P <0.05). Compared with gelatin sponge and alginate dressing hemostatic effect, The difference was not statistically significant. (2) Tube maintenance cost: Puncture point using gelatin sponge, The local maintenance costs of the catheter within 72 h after insertion of the tube are lowest, compared with alginate dressing and gauze was significant (P<0.05). Conclusion: The choice of compression hemostasis material for the puncture site after PICC implantation, using gelatin sponge and gauze dressing is more effective and economic.

  13. Scalable Video Transmission Over Multi-Rate Multiple Access Channels

    DTIC Science & Technology

    2007-06-01

    Rate - compatible punctured convolutional codes (RCPC codes ) and their ap- plications,” IEEE...source encoded using the MPEG-4 video codec. The source encoded bitstream is then channel encoded with Rate Compatible Punctured Convolutional (RCPC...Clark, and J. M. Geist, “ Punctured convolutional codes or rate (n-1)/n and simplified maximum likelihood decoding,” IEEE Transactions on

  14. Experience and nursing needs of school-age children undergoing lumbar puncture during the treatment of acute lymphoblastic leukaemia: a descriptive and qualitative study.

    PubMed

    Xie, Anwei; Shan, Yuying; Niu, Mei E; Chen, Yi; Wang, Xiya

    2017-11-01

    To describe experiences and nursing needs of school-age Chinese children undergoing lumbar puncture for the treatment of acute lymphoblastic leukaemia. Lumbar puncture is an invasive procedure, causing psychological changes and physical discomfort in patients. In a previous study, it was proved that distraction intervention, such as music therapy, relieves pain and anxiety. There is limited evidence regarding the experience and needs of school-age children during lumbar puncture after being diagnosed with acute lymphoblastic leukaemia. To minimise their anxiety and pain during the procedure, it is important to collect information directly from these children. A descriptive qualitative research. Twenty-one school-age children with acute lymphoblastic leukaemia participated in semi-structured interviews at a Children's Hospital in China. Data were collected by an experienced and trained interviewer. Qualitative content analysis was chosen to describe experiences of children undergoing lumbar puncture. While undergoing lumbar puncture for the treatment of acute lymphoblastic leukaemia, school-age Chinese children experienced complex psychological feelings (fear, tension, helplessness, sadness and anxiety). They also experienced physical discomfort. They had multipolar needs, such as information, communication, respect, self-actualisation, environment and equipment. This study identified important areas that must be closely monitored by healthcare staff, performing lumbar puncture on acute lymphoblastic leukaemia children. Thus, a successful and smooth procedure can be performed on these patients, and their quality of life can be improved. The experiences described in this study contribute to a better understanding of the needs of acute lymphoblastic leukaemia children undergoing lumbar puncture. They also provide valuable information to professional medical care staff that develops future nursing assessments. © 2016 John Wiley & Sons Ltd.

  15. Emergency Medicine Myths: Computed Tomography of the Head Prior to Lumbar Puncture in Adults with Suspected Bacterial Meningitis - Due Diligence or Antiquated Practice?

    PubMed

    April, Michael D; Long, Brit; Koyfman, Alex

    2017-09-01

    Various sources purport an association between lumbar puncture and brainstem herniation in patients with intracranial mass effect lesions. Several organizations and texts recommend head computed tomography (CT) prior to lumbar puncture in selected patients. To review the evidence regarding the utility of obtaining head CT prior to lumbar puncture in adults with suspected bacterial meningitis. Observational studies report a risk of post-lumbar puncture brainstem herniation in the presence of intracranial mass effect (1.5%) that is significantly lower than that reported among all patients with bacterial meningitis (up to 13.3%). It is unclear from existing literature whether identifying patients with intracranial mass effect decreases herniation risk. Up to 80% of patients with bacterial meningitis experiencing herniation have no CT abnormalities, and approximately half of patients with intracranial mass effect not undergoing lumbar puncture herniate. Decision rules to selectively perform CT on only those individuals most likely to have intracranial mass effect lesions have not undergone validation. Despite recommendations for immediate antimicrobial therapy prior to imaging, data indicate an association between pre-lumbar puncture CT and antibiotic delays. Recent data demonstrate shortened door-to-antibiotic times and lower mortality from bacterial meningitis after implementation of new national guidelines, which restricted generally accepted CT indications by removing impaired mental status as imaging criterion. Data supporting routine head CT prior to lumbar puncture are limited. Physicians should consider selective CT for those patients at risk for intracranial mass effect lesions based on decision rules or clinical gestalt. Patients undergoing head CT must receive immediate antibiotic therapy. Published by Elsevier Inc.

  16. Numerical method for computing Maass cusp forms on triply punctured two-sphere

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chan, K. T.; Kamari, H. M.; Zainuddin, H.

    2014-03-05

    A quantum mechanical system on a punctured surface modeled on hyperbolic space has always been an important subject of research in mathematics and physics. This corresponding quantum system is governed by the Schrödinger equation whose solutions are the Maass waveforms. Spectral studies on these Maass waveforms are known to contain both continuous and discrete eigenvalues. The discrete eigenfunctions are usually called the Maass Cusp Forms (MCF) where their discrete eigenvalues are not known analytically. We introduce a numerical method based on Hejhal and Then algorithm using GridMathematica for computing MCF on a punctured surface with three cusps namely the triplymore » punctured two-sphere. We also report on a pullback algorithm for the punctured surface and a point locater algorithm to facilitate the complete pullback which are essential parts of the main algorithm.« less

  17. Post-dural puncture headache

    PubMed Central

    Ghaleb, Ahmed; Khorasani, Arjang; Mangar, Devanand

    2012-01-01

    Since August Bier reported the first case in 1898, post-dural puncture headache (PDPH) has been a problem for patients following dural puncture. Clinical and laboratory research over the last 30 years has shown that use of smaller-gauge needles, particularly of the pencil-point design, are associated with a lower risk of PDPH than traditional cutting point needle tips (Quincke-point needle). A careful history can rule out other causes of headache. A postural component of headache is the sine qua non of PDPH. In high-risk patients < 50 years, post-partum, in the event a large-gauge needle puncture is initiated, an epidural blood patch should be performed within 24–48 hours of dural puncture. The optimum volume of blood has been shown to be 12–20 mL for adult patients. Complications caused by autologous epidural blood patching (AEBP) are rare. PMID:22287846

  18. Postdural Puncture Headache

    PubMed Central

    Ghaleb, Ahmed

    2010-01-01

    Postdural puncture headache (PDPH) has been a problem for patients, following dural puncture, since August Bier reported the first case in 1898. His paper discussed the pathophysiology of low-pressure headache resulting from leakage of cerebrospinal fluid (CSF) from the subarachnoid to the epidural space. Clinical and laboratory research over the last 30 years has shown that use of small-gauge needles, particularly of the pencil-point design, is associated with a lower risk of PDPH than traditional cutting point needle tips (Quincke-point needle). A careful history can rule out other causes of headache. A postural component of headache is the sine qua non of PDPH. In high-risk patients , for example, age < 50 years, postpartum, large-gauge needle puncture, epidural blood patch should be performed within 24–48 h of dural puncture. The optimum volume of blood has been shown to be 12–20 mL for adult patients. Complications of AEBP are rare. PMID:20814596

  19. 40 CFR Table 3 to Subpart Xxxx of... - Emission Limits for Puncture Sealant Application Affected Sources

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Emission Limits for Puncture Sealant Application Affected Sources 3 Table 3 to Subpart XXXX of Part 63 Protection of Environment ENVIRONMENTAL... Manufacturing Pt. 63, Subpt. XXXX, Table 3 Table 3 to Subpart XXXX of Part 63—Emission Limits for Puncture...

  20. 40 CFR Table 4 to Subpart Xxxx of... - Operating Limits for Puncture Sealant Application Control Devices

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Operating Limits for Puncture Sealant Application Control Devices 4 Table 4 to Subpart XXXX of Part 63 Protection of Environment ENVIRONMENTAL... Manufacturing Pt. 63, Subpt. XXXX, Table 4 Table 4 to Subpart XXXX of Part 63—Operating Limits for Puncture...

  1. Robot-Assisted Retinal Vein Cannulation with Force-Based Puncture Detection: Micron vs. the Steady-Hand Eye Robot*

    PubMed Central

    Gonenc, Berk; Tran, Nhat; Gehlbach, Peter; Taylor, Russell H.; Iordachita, Iulian

    2018-01-01

    Retinal vein cannulation is a demanding procedure where therapeutic agents are injected into occluded retina veins. The feasibility of this treatment is limited due to challenges in identifying the moment of venous puncture, achieving cannulation and maintaining it throughout the drug delivery period. In this study, we integrate a force-sensing microneedle with two distinct robotic systems: the handheld micromanipulator Micron, and the cooperatively controlled Steady-Hand Eye Robot (SHER). The sensed tool-to-tissue interaction forces are used to detect venous puncture and extend the robots’ standard control schemes with a new position holding mode (PHM) that assists the operator hold the needle position fixed and maintain cannulation for a longer time with less trauma on the vasculature. We evaluate the resulting systems comparatively in a dry phantom, stretched vinyl membranes. Results have shown that modulating the admittance control gain of SHER alone is not a very effective solution for preventing the undesired tool motion after puncture. However, after using puncture detection and PHM the deviation from the puncture point is significantly reduced, by 65% with Micron, and by 95% with SHER representing a potential advantage over freehand for both. PMID:28269417

  2. A novel in vivo model of puncture-induced iris neovascularization.

    PubMed

    Beaujean, Ophélie; Locri, Filippo; Aronsson, Monica; Kvanta, Anders; André, Helder

    2017-01-01

    To assess iris neovascularization by uveal puncture of the mouse eye and determine the role of angiogenic factors during iris neovascularization. Uveal punctures were performed on BalbC mouse eyes to induce iris angiogenesis. VEGF-blockage was used as an anti-angiogenic treatment, while normoxia- and hypoxia-conditioned media from retinal pigment epithelium (RPE) cells was used as an angiogenic-inducer in this model. Iris vasculature was determined in vivo by noninvasive methods. Iris blood vessels were stained for platelet endothelial cell adhesion molecule-1 and vascular sprouts were counted as markers of angiogenesis. Expression of angiogenic and inflammatory factors in the puncture-induced model were determined by qPCR and western blot. Punctures led to increased neovascularization and sprouting of the iris. qPCR and protein analysis showed an increase of angiogenic factors, particularly in the plasminogen-activating receptor and inflammatory systems. VEGF-blockage partly reduced iris neovascularization, and treatment with hypoxia-conditioned RPE medium led to a statistically significant increase in iris neovascularization. This study presents the first evidence of a puncture-induced iris angiogenesis model in the mouse. In a broader context, this novel in vivo model of neovascularization has the potential for noninvasive evaluation of angiogenesis modulating substances.

  3. Study of the damage rate caused by intervertebral foramen type inside and outside and the pass of the intervertebral DRG RF puncture way.

    PubMed

    Sun, Jiashu; Zhang, Haitao

    2014-09-01

    This paper was to analyze and contrast the damage rate on the thoracic segment different position of the dorsal root ganglion(dorsal root ganglion, DRG) caused by different puncture path in radiofrequency ablation, thus the best RF target way for the thoracic segment of different types of DRG was confirmed. According to the difference of puncture and ablation damage way, 14 segmental spinal specimens were randomly divided into three groups, and then conducted DRG radiofrequency damage on percutaneous puncture path according to the type of DRG position.The damage effect of different puncture path by the judgment standard of the result of pathology analyzed. The experiment showed that RF damage of group A were 72.58 ± 18.88%, 54.16 ± 24.84% and 32.85 ± 28.11%; that of group B were 771.86 ± 15.15% and 72.02 ± 17.86%, 57.14 ± 18.02% and 52.47 ± 20.64%, 68.75 ± 14.63% and 71.78 ± 16.00%; and that of group C were 82.46 ± 14.10%, 81.53 ± 11.81% and 80.83 ± 13.33%. It was concluded that the singleness of DRG puncture route is one of the important reasons for the poor thoracic segments DRG radiofrequency (RF) ablation effect. While according to the type of DRG different positions with double joint puncture path can significantly improve the rate of DRG RF damage.

  4. Challenging the wisdom of puncture at the calyceal fornix in percutaneous nephrolithotripsy: feasibility and safety study with 137 patients operated via a non-calyceal percutaneous track.

    PubMed

    Kyriazis, Iason; Kallidonis, Panagiotis; Vasilas, Marinos; Panagopoulos, Vasilios; Kamal, Wissam; Liatsikos, Evangelos

    2017-05-01

    To present our experience with a central, non-calyceal puncture protocol for percutaneous nephrolithotripsy (PCNL) in an attempt to challenge the opinion of worldwide adopted calyceal puncture as the less traumatic site of percutaneous entrance into the collecting system. During 2012, a total of 137 consecutive, unselected patients were subjected to PCNL in our department. Non-calyceal punctures were performed to all cases and followed by subsequent track dilations up to 30 Fr. Perioperative and postoperative data were prospectively collected and analyzed. Mean operative time (from skin puncture to nephrostomy tube placement) was 48 min. Patients with single, multiple and staghorn stones had primary stone-free rates of 89.2, 80.4 and 66.7 % after PCNL, respectively. The overall complication rate was 10.2 %, while bleeding complications were minimal. Only 4 patients (2.9 %) required blood transfusion. Five patients (3.6 %) had Clavien Grade IIIa complications requiring an intervention for their management and none Grade IV or V. Despite the absence of evidence that non-calyceal percutaneous tracts could be a risk factor for complications, the concept of calyceal puncture has been worldwide adopted by PCNL surgeons as the sole safe percutaneous entrance into the collective system. Based on our experience, other pathways than the worldwide recognized rule, calyceal puncture, are possible and probably not as dangerous as has been previously stated.

  5. Comparison of Ultrasound-Guided and Fluoroscopy-Assisted Antegrade Common Femoral Artery Puncture Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slattery, Michael M.; Goh, Gerard S.; Power, Sarah

    PurposeTo prospectively compare the procedural time and complication rates of ultrasound-guided and fluoroscopy-assisted antegrade common femoral artery (CFA) puncture techniques.Materials and MethodsHundred consecutive patients, undergoing a vascular procedure for which an antegrade approach was deemed necessary/desirable, were randomly assigned to undergo either ultrasound-guided or fluoroscopy-assisted CFA puncture. Time taken from administration of local anaesthetic to vascular sheath insertion in the superficial femoral artery (SFA), patients’ age, body mass index (BMI), fluoroscopy radiation dose, haemostasis method and immediate complications were recorded. Mean and median values were calculated and statistically analysed with unpaired t tests.ResultsSixty-nine male and 31 female patients underwent antegrademore » puncture (mean age 66.7 years). The mean BMI was 25.7 for the ultrasound-guided (n = 53) and 25.3 for the fluoroscopy-assisted (n = 47) groups. The mean time taken for the ultrasound-guided puncture was 7 min 46 s and for the fluoroscopy-assisted technique was 9 min 41 s (p = 0.021). Mean fluoroscopy dose area product in the fluoroscopy group was 199 cGy cm{sup 2}. Complications included two groin haematomas in the ultrasound-guided group and two retroperitoneal haematomas and one direct SFA puncture in the fluoroscopy-assisted group.ConclusionUltrasound-guided technique is faster and safer for antegrade CFA puncture when compared to the fluoroscopic-assisted technique alone.« less

  6. Direct right ventricular puncture for hemodynamic evaluation of a mechanical tricuspid valve prosthesis: a new indication for an old procedure.

    PubMed

    Gibson, M A; Carell, E S

    1997-11-01

    The advent of transvenous right heart catheterization has relegated direct transthoracic right ventricular puncture largely to the role of "interesting historical footnote." However, in the case of a right ventricle that is "protected" by a mechanical tricuspid valve prosthesis, direct right ventricular puncture represents a reasonable alternative for obtaining accurate hemodynamic information.

  7. Development of a new bench for puncturing of irradiated fuel rods in STAR hot laboratory

    NASA Astrophysics Data System (ADS)

    Petitprez, B.; Silvestre, P.; Valenza, P.; Boulore, A.; David, T.

    2018-01-01

    A new device for puncturing of irradiated fuel rods in commercial power plants has been designed by Fuel Research Department of CEA Cadarache in order to provide experimental data of high precision on fuel pins with various designs. It will replace the current set-up that has been used since 1998 in hot cell 2 of STAR facility with more than 200 rod puncturing experiments. Based on this consistent experimental feedback, the heavy-duty technique of rod perforation by clad punching has been preserved for the new bench. The method of double expansion of rod gases is also retained since it allows upgrading the confidence interval of volumetric results obtained from rod puncturing. Furthermore, many evolutions have been introduced in the new design in order to improve its reliability, to make the maintenance easier by remote handling and to reduce experimental uncertainties. Tightness components have been studied with Sealing Laboratory Maestral at Pierrelatte so as to make them able to work under mixed pressure conditions (from vacuum at 10-5 mbar up to pressure at 50 bars) and to lengthen their lifetime under permanent gamma irradiation in hot cell. Bench ergonomics has been optimized to make its operating by remote handling easier and to secure the critical phases of a puncturing experiment. A high pressure gas line equipped with high precision pressure sensors out of cell can be connected to the bench in cell for calibration purposes. Uncertainty analyses using Monte Carlo calculations have been performed in order to optimize capacity of the different volumes of the apparatus according to volumetric characteristics of the rod to be punctured. At last this device is composed of independent modules which allow puncturing fuel pins out of different geometries (PWR, BWR, VVER). After leak tests of the device and remote handling simulation in a mock-up cell, several punctures of calibrated specimens have been performed in 2016. The bench will be implemented soon in hot cell 2 of STAR facility for final qualification tests. PWR rod punctures are already planned for 2018.

  8. Access site complications and puncture site pain following transradial coronary procedures: a correlational study.

    PubMed

    Cheng, Ka Yan; Chair, Sek Ying; Choi, Kai Chow

    2013-10-01

    Transradial coronary angiography (CA) and percutaneous coronary intervention (PCI) are gaining worldwide popularity due to the low incidence of major vascular complications and early mobilization of patients post procedures. Although post transradial access site complications are generally considered as minor in nature, they are not being routinely recorded in clinical settings. To evaluate the incidence of access site complications and level of puncture site pain experienced by patients undergoing transradial coronary procedures and to examine factors associated with access site complications occurrence and puncture site pain severity. A cross-sectional correlational study of 85 Chinese speaking adult patients scheduled for elective transradial CA and or PCI. Ecchymosis, bleeding, hematoma and radial artery occlusion (RAO) were assessed through observation, palpation and plethysmographic signal of pulse oximetry after coronary procedures. Puncture site pain was assessed with a 100mm Visual Analogue Scale. Factors that were related to access site complications and puncture site pain were obtained from medical records. Ecchymosis was the most commonly reported transradial access site complication in this study. Paired t-test showed that the level of puncture site pain at 24 h was significantly (p<0.001) lower than that at 3 h after the procedure. Stepwise multivariable regression showed that female gender and shorter sheath time were found to be significantly associated with bleeding during gradual deflation of compression device. Only longer sheath time was significantly associated with RAO. Female gender and larger volume of compression air were associated with the presence of ecchymosis and puncture site pain at 3 h after procedure, respectively. The study findings suggest that common access site complications post transradial coronary procedures among Chinese population are relatively minor in nature. Individual puncture site pain assessment during the period of hemostasis is important. Nurses should pay more attention to factors such as female gender, sheath time and volume of compression that are more likely to be associated with transradial access site complications and puncture site pain. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Puncture Reduction in Percutaneous Transforaminal Endoscopic Discectomy with HE's Lumbar LOcation (HELLO) System: A Cadaver Study.

    PubMed

    Fan, Guoxin; Guan, Xiaofei; Sun, Qi; Hu, Annan; Zhu, Yanjie; Gu, Guangfei; Zhang, Hailong; He, Shisheng

    2015-01-01

    Percutaneous transforaminal endoscopic discectomy (PTED) usually requires numerous punctures under X-ray fluoroscopy. Repeated puncture will lead to more radiation exposure and reduce the beginners' confidence. This cadaver study aimed to investigate the efficacy of HE's Lumbar Location (HELLO) system in puncture reduction of PTED. Cadaver study. Comparative groups. HELLO system consists of self-made surface locator and puncture locator. One senior surgeon conducted the puncture procedure of PTED on the left side of 20 cadavers at L4/L5 and L5/S1 level with the assistance of HELLO system (Group A). Additionally, the senior surgeon conducted the puncture procedure of PTED on the right side of the cadavers at L4/L5 and L5/S1 level with traditional methods (Group B). On the other hand, an inexperienced surgeon conducted the puncture procedure of PTED on the left side of the cadavers at L4/L5 and L5/S1 level with the assistance of our HELLO system (Group C). At L4/L5 level, there was significant difference in puncture times between Group A and Group B (P<0.001), but no significant difference was observed between Group A and Group C (P = 0.811). Similarly at L5/S1 level, there was significant difference in puncture times between Group A and Group B (P<0.001), but no significant difference was observed between Group A and Group C (P = 0.981). At L4/L5 level, there was significant difference in fluoroscopy time between Group A and Group B (P<0.001), but no significant difference was observed between Group A and Group C (P = 0.290). Similarly at L5/S1 level, there was significant difference in fluoroscopy time between Group A and Group B (P<0.001), but no significant difference was observed between Group A and Group C (P = 0.523). As for radiation exposure, HELLO system reduced 39%-45% radiation dosage when comparing Group A and Group B, but there was no significant difference in radiation exposure between Group A and Group C whatever at L4/L5 level or L5/S1 level (P>0.05). There was no difference in location time between Group A and Group B or Group A and Group C either at L4/L5 level or L5/S1 level (P>0.05). Small-sample preclinical study. HELLO system was effective in reducing puncture times, fluoroscopy time and radiation exposure, as well as the difficulty of learning PTED. (2015-RES-127).

  10. [Percutaneous renal puncture guide by a novel real-time needle-tracking ultrasound system for percutaneous nephrolithotomy: analysis of 16 cases].

    PubMed

    Ma, Kai; Huang, Xiao-bo; Xiong, Liu-lin; Xu, Qing-quan; Xu, Tao; Ye, Hai-yun; Yu, Lu-ping; Wang, Xiao-feng

    2014-08-18

    To evaluate the feasibility and efficacy of percutaneous renal puncture in percutaneous nephrolithotomy guided by novel needle-tracking ultrasound system. From may to october 2013, 16 cases of percutaneous nephrolithotomy were performed under the guidance of ultrasound system. The clinical data including the time of completing percutaneous renal puncture, the color of urine sucked out from the kidney calices, and the complications were analyzed retrospectively. Of the 16 patients, 18 percutaneous renal access were established guided by ultrasound system. All of them were successtul for the first time, and the average time of completing percutaneous renal punctures was (26.90 ± 11.37) s (15 to 54 s). After the operation, the hemoglobin decreased by (9.56 ± 5.27)%(1.41% to 24.06%), and no complications occurred except for postoperative fever in 2 case. The novel ultrasound system is a safe and effective technique that can reduce the technical difficulty of percutaneous renal puncture in percutaneous nephrolithotomy.

  11. Use of Lumbar Punctures in the Management of Ocular Syphilis.

    PubMed

    Reekie, Ian; Reddy, Yaviche

    2018-01-01

    Ocular syphilis has become rare in the developed world, but is a common presentation to ophthalmology departments in South Africa. We investigated the proportion of patients diagnosed with ocular syphilis who went on to receive lumbar punctures, and determined the fraction of these who had cerebrospinal fluid findings suggestive of neurosyphilis. We aimed to determine whether the use of lumbar punctures in ocular syphilis patients was beneficial in picking up cases of neurosyphilis. Retrospective study of case notes of patients admitted to two district hospitals in Durban, South Africa, with ocular syphilis over a 20-month period. A total of 31 of 68 ocular syphilis patients underwent lumbar puncture, and of these, eight (25.8%) had findings suggestive of neurosyphilis. Lumbar puncture in ocular syphilis patients should continue to be a routine part of the investigation of these patients; a large proportion of ocular syphilis patients show cerebrospinal fluid findings suggestive of neurosyphilis, are at risk of the complications of neurosyphilis, and should be managed accordingly.

  12. Performance Analysis of IEEE 802.11g TCM Waveforms Transmitted over a Channel with Pulse-Noise Interference

    DTIC Science & Technology

    2007-06-01

    17 Table 2. Best (maximum free distance) rate r=2/3 punctured convolutional code ...Hamming distance between all pairs of non-zero paths. Table 2 lists the best rate r=2/3, punctured convolutional code information weight structure dB...Table 2. Best (maximum free distance) rate r=2/3 punctured convolutional code information weight structure. (From: [12]). K freed freeB

  13. Technical Note: Thoracic duct embolization for treatment of chylothorax: A novel guidance technique for puncture using combined MRI and fluoroscopy.

    PubMed

    Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth

    2012-04-01

    Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct.

  14. DNA duplication is essential for the repair of gastrointestinal perforation in the insect midgut

    PubMed Central

    Huang, Wuren; Zhang, Jie; Yang, Bing; Beerntsen, Brenda T.; Song, Hongsheng; Ling, Erjun

    2016-01-01

    Invertebrate animals have the capacity of repairing wounds in the skin and gut via different mechanisms. Gastrointestinal perforation, a hole in the human gastrointestinal system, is a serious condition, and surgery is necessary to repair the perforation to prevent an abdominal abscess or sepsis. Here we report the repair of gastrointestinal perforation made by a needle-puncture wound in the silkworm larval midgut. Following insect gut perforation, only a weak immune response was observed because the growth of Escherichia coli alone was partially inhibited by plasma collected at 6 h after needle puncture of the larval midgut. However, circulating hemocytes did aggregate over the needle-puncture wound to form a scab. While, cell division and apoptosis were not observed at the wound site, the needle puncture significantly enhanced DNA duplication in cells surrounding the wound, which was essential to repair the midgut perforation. Due to the repair capacity and limited immune response caused by needle puncture to the midgut, this approach was successfully used for the injection of small compounds (ethanol in this study) into the insect midgut. Consequently, this needle-puncture wounding of the insect gut can be developed for screening compounds for use as gut chemotherapeutics in the future. PMID:26754166

  15. A novel in vivo model of puncture-induced iris neovascularization

    PubMed Central

    Aronsson, Monica; Kvanta, Anders

    2017-01-01

    Purpose To assess iris neovascularization by uveal puncture of the mouse eye and determine the role of angiogenic factors during iris neovascularization. Methods Uveal punctures were performed on BalbC mouse eyes to induce iris angiogenesis. VEGF-blockage was used as an anti-angiogenic treatment, while normoxia- and hypoxia-conditioned media from retinal pigment epithelium (RPE) cells was used as an angiogenic-inducer in this model. Iris vasculature was determined in vivo by noninvasive methods. Iris blood vessels were stained for platelet endothelial cell adhesion molecule-1 and vascular sprouts were counted as markers of angiogenesis. Expression of angiogenic and inflammatory factors in the puncture-induced model were determined by qPCR and western blot. Results Punctures led to increased neovascularization and sprouting of the iris. qPCR and protein analysis showed an increase of angiogenic factors, particularly in the plasminogen-activating receptor and inflammatory systems. VEGF-blockage partly reduced iris neovascularization, and treatment with hypoxia-conditioned RPE medium led to a statistically significant increase in iris neovascularization. Conclusions This study presents the first evidence of a puncture-induced iris angiogenesis model in the mouse. In a broader context, this novel in vivo model of neovascularization has the potential for noninvasive evaluation of angiogenesis modulating substances. PMID:28658313

  16. Efficacy and safety of nitroglycerin for preventing venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator leads implantation.

    PubMed

    Duan, Xu; Ling, Feng; Shen, Yun; Yang, Jun; Xu, Hai-ying; Tong, Xiao-shan

    2013-04-01

    We investigated the efficacy and safety of nitroglycerin for preventing venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator leads implantation. A total of 40 consecutive patients referred for contrast-guided axillary vein puncture for pacemaker or defibrillator implantations were included in the study. Patients were randomly assigned to control group and nitroglycerin group. Patients in the nitroglycerin group were given 200 µg (2 mL) nitroglycerin via ipsilateral peripheral vein about 3 min before puncture. The degree of venous spasm was evaluated by the reduction in lumen calibre of the axillary vein after puncture. Mild venous spasm and severe venous spasm were defined as a reduction in lumen calibre of 50-90% and ≥ 90%, respectively. The mean degree of venous spasm of axillary vein was lower in the nitroglycerin group than in the control group (23.0 ± 22.3 vs. 45.5 ± 33.6%, P = 0.018). The incidence of mild or severe venous spasm was lower in the nitroglycerin group than in the control group (3/20 vs. 11/20, P = 0.019). In the nitroglycerin group, the systolic blood pressure had a significant decrease after puncture (129.5 ± 23.7 vs. 143.0 ± 24.1 mmHg, P = 0.003). There was no hypotension and other adverse reaction of nitroglycerin in the nitroglycerin group. Intravenous nitroglycerin is effective and safe for preventing venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator leads implantation.

  17. Dura-arachnoid lesions produced by 22 gauge Quincke spinal needles during a lumbar puncture

    PubMed Central

    Reina, M; Lopez, A; Badorrey, V; De Andres, J A; Martin, S

    2004-01-01

    Aims: The dural and arachnoid hole caused by lumbar puncture needles is a determining factor in triggering headaches. The aim of this study is to assess the dimensions and morphological features of the dura mater and arachnoids when they are punctured by a 22 gauge Quincke needle having its bevel either in the parallel or in the transverse position. Methods: Fifty punctures were made with 22 gauge Quincke needles in the dural sac of four fresh cadavers using an "in vitro" model especially designed for this purpose. The punctures were performed by needles with bevels parallel or perpendicular to the spinal axis and studied under scanning electron microscopy. Results: Thirty five of the 50 punctures done by Quincke needles (19 in the external surface and 16 in the internal) were used for evaluation. When the needle was inserted with its bevel parallel to the axis of the dural sac (17 of 35), the size of the dura-arachnoid lesion was 0.032 mm2 in the epidural surface and 0.037 mm2 in the subarachnoid surface of the dural sac. When the needle's bevel was perpendicular to the axis (18 of 35) the measurement of the lesion size was 0.042 mm2 for the external surface and 0.033 mm2 for the internal. There were no statistical significant differences between these results. Conclusions: It is believed that the reported lower frequency of postdural puncture headache when the needle is inserted parallel to the cord axis should be explained by some other factors besides the size of the dura-arachnoid injury. PMID:15146008

  18. Dura-arachnoid lesions produced by 22 gauge Quincke spinal needles during a lumbar puncture.

    PubMed

    Reina, M A; López, A; Badorrey, V; De Andrés, J A; Martín, S

    2004-06-01

    The dural and arachnoid hole caused by lumbar puncture needles is a determining factor in triggering headaches. The aim of this study is to assess the dimensions and morphological features of the dura mater and arachnoids when they are punctured by a 22 gauge Quincke needle having its bevel either in the parallel or in the transverse position. Fifty punctures were made with 22 gauge Quincke needles in the dural sac of four fresh cadavers using an "in vitro" model especially designed for this purpose. The punctures were performed by needles with bevels parallel or perpendicular to the spinal axis and studied under scanning electron microscopy. Thirty five of the 50 punctures done by Quincke needles (19 in the external surface and 16 in the internal) were used for evaluation. When the needle was inserted with its bevel parallel to the axis of the dural sac (17 of 35), the size of the dura-arachnoid lesion was 0.032 mm(2) in the epidural surface and 0.037 mm(2) in the subarachnoid surface of the dural sac. When the needle's bevel was perpendicular to the axis (18 of 35) the measurement of the lesion size was 0.042 mm(2) for the external surface and 0.033 mm(2) for the internal. There were no statistical significant differences between these results. It is believed that the reported lower frequency of postdural puncture headache when the needle is inserted parallel to the cord axis should be explained by some other factors besides the size of the dura-arachnoid injury.

  19. Lower incidence of postdural puncture headache using whitacre spinal needles after spinal anesthesia: A meta-analysis.

    PubMed

    Zhang, Di; Chen, LingXiao; Chen, XingYu; Wang, XiaoBo; Li, YuLin; Ning, GuangZhi; Feng, ShiQing

    2016-03-01

    The aim of this meta-analysis was to evaluate the postdural puncture headache after spinal anesthesia with Whitacre spinal needles compared with Quincke spine needles. We searched several databases, including PubMed, Embase, ISI Web of Knowledge, and Cochrane Central Register of Controlled Trials until October 10th, 2014, for randomized controlled trials that compared spinal anesthesia with Whitacre spinal needles or Quincke spine needles for postdural puncture headache. Two reviewers independently screened the literature, assessed the risk for bias and extracted data. We used RevMan 5.3 software to perform the meta-analysis. Studies were included for the main end points if they addressed the following: frequency of postdural puncture headache, severity of postdural puncture headache as assessed by limitation of activities, and frequency of epidural blood patch. Nine randomized controlled trials were included for meta-analysis. The meta-analysis showed that spinal anesthesia with Whitacre spinal needles achieved lower incidence of postdural puncture headache(RR 0.34; 95% CI [0.22, 0.52]; P < .00001); in addition, the severity of postdural puncture headache was lower in the Whitacre spinal needle group (RR 0.32; 95% CI [0.16, 0.66]; P = .002). Furthermore, the frequency of an epidural blood patch in the Whitacre spinal needle group was lower compared with that in the Quincke spine needle group (RR 0.15; 95% CI [0.04, 0.51]; P = .002). We suggest the Whitacre spinal needles as a superior choice for spinal anesthesia compared with Quincke spine needles. © 2016 American Headache Society.

  20. Incidence of tissue coring during transseptal catheterization when using electrocautery and a standard transseptal needle.

    PubMed

    Greenstein, Eugene; Passman, Rod; Lin, Albert C; Knight, Bradley P

    2012-04-01

    The application of radiofrequency electrocautery to a standard, open-ended transseptal needle has been used to facilitate transseptal puncture (TSP). The purpose of this study was to determine the incidence of cardiac tissue coring when this technique is used. A model using excised swine hearts submerged in a saline-filled basin was developed to simulate TSP with electrocautery and a standard transseptal needle. Punctures were performed without the use of electrocautery and by delivering radiofrequency energy to the transseptal needle using a standard electrocautery pen at 3 target sites (fossa ovalis, non-fossa ovalis septum, and aorta). The tissue of the submerged heart was gently tented, and the needle was advanced on delivery of radiofrequency. The devices were retracted, and the needle was flushed in a collection basin. None of the TSPs without cautery caused tissue coring. For TSPs using electrocautery, the frequency of coring was at least 21% for any puncture permutation used in the study and averaged 37% at septal sites (P<0.001 compared with punctures without cautery). Tissue coring occurred in 33 of 96 (35%) punctures through the fossa ovalis and in 38 of 96 (40%) punctures through non-fossa ovalis septum. The frequency of tissue coring at aortic sites was 62 of 96 (65%), which was significantly higher than at the septal sites (P<0.001). In an animal preparation, TSP at the level of the fossa ovalis using electrocautery and a standard open-ended Brockenbrough needle resulted in coring of the septal tissue in 35% of cases (33 of 96 punctures).

  1. Causes and Solutions of the Trampoline Effect.

    PubMed

    Miwa, Masamiki; Ota, Noboru; Ando, Chiyono; Miyazaki, Yukio

    2015-01-01

    A trampoline effect may occur mainly when a buttonhole tract and the vessel flap fail to form a straight line. Certain findings, however, suggest another cause is when the vessel flap is too small. The frequency of the trampoline effect, for example, is lower when a buttonhole tract is created by multiple punctures of the arteriovenous fistula (AVF) vessel than when it is done by one-time puncture of the vessel. Lower frequency of the trampoline effect with multiple punctures of the AVF vessel may be due to enlargement of the initial puncture hole on the vessel every time the vessel is punctured with a sharp needle. Even if aiming at exactly the same point on the AVF vessel every time, the actual puncture point shifts slightly at every puncture, which potentially results in enlargement of the initial hole on the AVF vessel. Moreover, in some patients, continued use of a buttonhole tract for an extended period of time increases the frequency of the trampoline effect. In such cases, reduction of the incidence of the trampoline effect can be achieved by one buttonhole cannulation using a new dull needle with sharp side edges that is used to enlarge the vessel flap. Such single buttonhole cannulation may suggest that the increased frequency of the trampoline effect also potentially occurs in association with gradually diminishing flap size. As a final observation, dull needle insertion into a vessel flap in the reverse direction has been more smoothly achieved than insertion into a vessel flap in the conventional direction. A vessel flap in the reverse direction can be adopted clinically. © 2015 S. Karger AG, Basel.

  2. Inexpensive homemade models for ultrasound-guided vein cannulation training.

    PubMed

    Di Domenico, Stefano; Santori, Gregorio; Porcile, Elisa; Licausi, Martina; Centanaro, Monica; Valente, Umberto

    2007-11-01

    To test the hypothesis that low-cost homemade models may be used to acquire the basic skills for ultrasound-guided central vein puncture. Training study. University transplantation department. Training was performed using three different homemade models (A, B, and C). Segments of a common rubber tourniquet (V1) and Silastic tube (V2) were used to simulate vessels within agar-based models. Overall cost for each model was less than 5 euro (US$7). For each test (test I, A-V1; II, A-V2; III, B-V1; IV, C-V2), the number of punctures and attempts needed to locate the needle inside the lumen were recorded. Each test was considered completed when participants punctured the vessels at the first attempt for three consecutive times. In test I, the mean number of punctures and attempts were 3.85 +/- 1.26 and 4.95 +/- 3.05; in test II, 4.60 +/- 1.14 and 6.30 +/- 2.51; in test III, 4.80 +/- 1.06 and 4.65 +/- 2.21; and in test IV, 4.45 +/- 1.23 and 6.05 +/- 2.92, respectively. For each test, no statistical difference was found by comparison of number of punctures and attempts for anesthesiologists versus nonanesthesiologists, men versus women, or previous experience versus no experience with central vein cannulation (CVC). Video game users obtained better results than did nonusers in test I (punctures, P = 0.033; attempts, P = 0.038), test II (punctures, P = 0.052; attempts, P = 0.011), and test IV (punctures, P = 0.001; attempts, P = 0.003). A posttraining questionnaire showed favorable opinions about the clarity of the instructions, aptness of the models, and adequacy of the training. In our operative unit, the use of ultrasound guidance for CVC increased from 2% to 23% in the first month after training. Low-cost homemade models are useful in acquiring basic coordination skills for ultrasound-guided CVC.

  3. The pie-crusting technique using a blade knife for medial collateral ligament release is unreliable in varus total knee arthroplasty.

    PubMed

    Kwak, Dai-Soon; In, Yong; Kim, Tae Kyun; Cho, Han Suk; Koh, In Jun

    2016-01-01

    Despite the documented clinical efficacy of the pie-crusting technique for medial collateral ligament (MCL) release in varus total knee arthroplasty, its quantitative effects on medial gaps and safety remain unclear. This study was undertaken to determine the efficacy (quantitative effect and consistency of the number of punctures) and the safety (frequency of early over-release) of the pie-crusting technique for MCL release. From ten pairs of cadaveric knees, one knee from each pair was randomly assigned to undergo pie crusting in extension (group E) or in flexion (group F). Pie crusting was performed in the superficial MCL using a blade until over-release occurred. After every puncture, the incremental medial gap increase was recorded, and the number of punctures required for 2- or 4-mm gap increases was assessed. In group E, the extension gap increased from 0.8 to 5.0 mm and the flexion gap increased from 0.8 to 3.0 mm. In group F, the extension gap increased from 1.0 to 3.0 mm and the flexion gap increased from 2.6 to 6.0 mm. However, the gap increments were inconsistent with those that followed the preceding blade punctures, and the number of punctures required to increase the gaps by 2 or 4 mm was variable. The number of punctures leading to over-release in group E and group F was 6 ± 1 and 3 ± 1 punctures, respectively. Overall, 70% of over-release occurred earlier than the average number of punctures leading to over-release. Pie crusting led to unpredictable gap increments and to frequent early over-release. Surgeons should decide carefully before using the pie-crusting technique for MCL release and should be cautious of performing throughout the procedure, especially when performing in a flexed knee. Therapeutic study, Level I.

  4. Performance Analysis of Hybrid ARQ Protocols in a Slotted Code Division Multiple-Access Network

    DTIC Science & Technology

    1989-08-01

    Convolutional Codes . in Proc Int. Conf. Commun., 21.4.1-21.4.5, 1987. [27] J. Hagenauer. Rate Compatible Punctured Convolutional Codes . in Proc Int. Conf...achieved by using a low rate (r = 0.5), high constraint length (e.g., 32) punctured convolutional code . Code puncturing provides for a variable rate code ...investigated the use of convolutional codes in Type II Hybrid ARQ protocols. The error

  5. Vascular access: the impact of ultrasonography

    PubMed Central

    de Almeida, Carlos Eduardo Saldanha

    2016-01-01

    ABSTRACT Vascular punctures are often necessary in critically ill patients. They are secure, but not free of complications. Ultrasonography enhances safety of the procedure by decreasing puncture attempts, complications and costs. This study reviews important publications and the puncture technique using ultrasound, bringing part of the experience of the intensive care unit of the Hospital Israelita Albert Einstein, São Paulo (SP), Brazil, and discussing issues that should be considered in future studies. PMID:28076607

  6. Technical Note: Thoracic duct embolization for treatment of chylothorax: A novel guidance technique for puncture using combined MRI and fluoroscopy

    PubMed Central

    Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth

    2012-01-01

    Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct. PMID:23162248

  7. [An atraumatic needle for the puncture of ports and pumps].

    PubMed

    Haindl, H; Müller, H

    1988-10-17

    Huber-point needles have been found to induce substantial coring during puncture of ports or pumps, which may lead to leakage or obturation of these devices. Therefore, different types of cannulas were tested in order to evaluate their applicability for this purpose. Pencil-point needles led to increased pain during puncture and thus seemed unsuitable. A newly developed port-cannula bent inwards within the length of the bevel ("protected bevel") and proved to be definitely noncoring during electron microscopy. Consequently the force required to introduce this needle was reduced by 50% in comparison with the Huber-type needle. In addition, this cannula allowed up to 3000 punctures of one port without leakage and, thus, correspondingly therefore relevantly increased the durability of this device.

  8. The effect of second-stage pushing and body mass index on postdural puncture headache.

    PubMed

    Franz, Amber M; Jia, Shawn Y; Bahnson, Henry T; Goel, Akash; Habib, Ashraf S

    2017-02-01

    To explore how pushing during labor and body mass index affect the development of postdural puncture headache in parturients who experienced dural puncture with Tuohy needles. Retrospective cohort. Obstetric ward and operating rooms at a university-affiliated hospital. One hundred ninety parturients who had witnessed dural puncture with 17 or 18 gauge Tuohy needles from 1999-2014. Patients were categorized by pushing status and body mass index (kg/m 2 ): nonobese <30, obese 30-39.99, morbidly obese 40-49.99, and super obese ≥50. Headache, number of days of headache, maximum headache score, and epidural blood patch placement. Compared with women who did not push, women who pushed during labor had increased risk of postdural puncture headache (odds ratio [OR], 2.1 [1.1-4.0]; P=.02), more days of headache (P=.02), and increased epidural blood patch placement (P=.02). Super obese patients were less likely to develop headache compared with nonobese (OR, 0.33 [0.13-0.85]; P=.02), obese (OR, 0.37 [0.14-0.98]; P=.045], and morbidly obese patients (OR, 0.20 [0.05-0.68]; P<.01). In a multivariate logistic regression model, lack of pushing (OR, 0.57 [0.29-1.10]; P=.096) and super obesity (OR, 0.41 [0.16-1.02]; P=.056] were no longer significantly associated with reduced risk of postdural puncture headache. Parturients who did not push before delivery and parturients with body mass index ≥50kg/m 2 were less likely to develop postdural puncture headache in a univariate analysis. Similar trends were demonstrated in a multivariate model, but were no longer statistically significant. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Effects of subcutaneously infiltrated nitroglycerin on diameter, palpability, ease-of-puncture and pre-cannulation spasm of radial artery during transradial coronary angiography.

    PubMed

    Ezhumalai, Babu; Satheesh, Santhosh; Jayaraman, Balachander

    2014-01-01

    The success of transradial catheterization depends on meticulous access of radial artery which in turn depends on palpating a good radial pulse. Our objectives were to analyze the effects of subcutaneously infiltrated nitroglycerin on diameter of radial artery, palpability of radial pulse, ease-of-puncture and pre-cannulation spasm of radial artery during transradial coronary angiography. Patients undergoing transradial coronary angiography were randomized to Group NL or Group SL. In Group NL, 3 ml of solution containing nitroglycerin and lignocaine was infiltrated subcutaneously at the site intended for puncture of radial artery. Similarly, saline and lignocaine were infiltrated in Group SL. Diameter of radial artery was objectively assessed by ultrasonography. Measurements were performed at baseline and repeated at 1 min after injecting the solutions. The ease-of-puncture was evaluated by the number of punctures and the time needed for successful access of radial artery. Both groups had 100 patients each. Baseline diameter of radial artery was similar between two groups. The post-injection diameter of radial artery increased by 26.3% in Group NL and 11.4% in Group SL. Nitroglycerin significantly improved the palpability of radial pulse, reduced the number of punctures and shortened the time needed for successful access of radial artery. Pre-cannulation spasm of radial artery occurred in 1% of Group NL and 8% of Group SL. Subcutaneously infiltrated nitroglycerin leads to significant vasodilation of radial artery. This avoids pre-cannulation spasm of radial artery, enhances palpability of the radial pulse and thus makes the puncture of radial artery easier. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  10. Effects of subcutaneously infiltrated nitroglycerin on diameter, palpability, ease-of-puncture and pre-cannulation spasm of radial artery during transradial coronary angiography

    PubMed Central

    Ezhumalai, Babu; Satheesh, Santhosh; Jayaraman, Balachander

    2014-01-01

    Background The success of transradial catheterization depends on meticulous access of radial artery which in turn depends on palpating a good radial pulse. Objectives Our objectives were to analyze the effects of subcutaneously infiltrated nitroglycerin on diameter of radial artery, palpability of radial pulse, ease-of-puncture and pre-cannulation spasm of radial artery during transradial coronary angiography. Methods Patients undergoing transradial coronary angiography were randomized to Group NL or Group SL. In Group NL, 3 ml of solution containing nitroglycerin and lignocaine was infiltrated subcutaneously at the site intended for puncture of radial artery. Similarly, saline and lignocaine were infiltrated in Group SL. Diameter of radial artery was objectively assessed by ultrasonography. Measurements were performed at baseline and repeated at 1 min after injecting the solutions. The ease-of-puncture was evaluated by the number of punctures and the time needed for successful access of radial artery. Results Both groups had 100 patients each. Baseline diameter of radial artery was similar between two groups. The post-injection diameter of radial artery increased by 26.3% in Group NL and 11.4% in Group SL. Nitroglycerin significantly improved the palpability of radial pulse, reduced the number of punctures and shortened the time needed for successful access of radial artery. Pre-cannulation spasm of radial artery occurred in 1% of Group NL and 8% of Group SL. Conclusions Subcutaneously infiltrated nitroglycerin leads to significant vasodilation of radial artery. This avoids pre-cannulation spasm of radial artery, enhances palpability of the radial pulse and thus makes the puncture of radial artery easier. PMID:25634390

  11. Evolving a Puncture Black Hole with Fixed Mesh Refinement

    NASA Technical Reports Server (NTRS)

    Imbiriba, Breno; Baker, John; Choi, Dae-II; Centrella, Joan; Fiske. David R.; Brown, J. David; vanMeter, James R.; Olson, Kevin

    2004-01-01

    We present a detailed study of the effects of mesh refinement boundaries on the convergence and stability of simulations of black hole spacetimes. We find no technical problems. In our applications of this technique to the evolution of puncture initial data, we demonstrate that it is possible to simulaneously maintain second order convergence near the puncture and extend the outer boundary beyond 100M, thereby approaching the asymptotically flat region in which boundary condition problems are less difficult.

  12. Design and System Implications of a Family of Wideband HF Data Waveforms

    DTIC Science & Technology

    2010-09-01

    code rates (i.e. 8/9, 9/10) will be used to attain the highest data rates for surface wave links. Very high puncturing of convolutional codes can...Communication Links”, Edition 1, North Atlantic Treaty Organization, 2009. [14] Yasuda, Y., Kashiki, K., Hirata, Y. “High- Rate Punctured Convolutional Codes ...length 7 convolutional code that has been used for over two decades in 110A. In addition, repetition coding and puncturing was

  13. Aerosol can puncture device operational test plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leist, K.J.

    1994-05-03

    Puncturing of aerosol cans is performed in the Waste Receiving and Processing Facility Module 1 (WRAP 1) process as a requirement of the waste disposal acceptance criteria for both transuranic (TRU) waste and low-level waste (LLW). These cans have contained such things as paints, lubricating oils, paint removers, insecticides, and cleaning supplies which were used in radioactive facilities. Due to Westinghouse Hanford Company (WHC) Fire Protection concerns of the baseline system`s fire/explosion proof characteristics, a study was undertaken to compare the baseline system`s design to commercially available puncturing devices. While the study found no areas which might indicate a riskmore » of fire or explosion, WHC Fire Protection determined that the puncturing system must have a demonstrated record of safe operation. This could be obtained either by testing the baseline design by an independent laboratory, or by substituting a commercially available device. As a result of these efforts, the commercially available Aerosolv can puncturing device was chosen to replace the baseline design. Two concerns were raised with the system. Premature blinding of the coalescing/carbon filter, due to its proximity to the puncture and draining operation; and overpressurization of the collection bottle due to its small volume and by blinding of the filter assembly. As a result of these concerns, testing was deemed necessary. The objective of this report is to outline test procedures for the Aerosolv.« less

  14. Comparison of 25 G and 29 G Quincke spinal needles in paediatric day case surgery. A prospective randomized study of the puncture characteristics, success rate and postoperative complaints.

    PubMed

    Kokki, H; Hendolin, H

    1996-01-01

    A comparison of a 25 G with a 29 G Quincke needle was performed in paediatric day case surgery. Sixty healthy children aged 1 year to 13 years were randomly allocated to have spinal anaesthesia with either 25 G or 29 G Quincke needle without an introducer needle. There was a failure rate of 10% with the 29 G spinal needle compared with 0% with the 25 G needle. The time needed to perform dural puncture was shorter using 25 G than 29 G needle, 22 (+/- 31)(SD) vs 59 (+/- 63) s. The time taken for cerebrospinal fluid to appear at the needle hub was also longer, 4 (+/- 3) vs 8 (+/- 5) s. The number of puncture attempts was similar, 1.2 (+/- 0.6) vs 1.4 (+/- 0.8), with 25 G and 29 G needle. Low back pain, 5 vs1, and nonpositional headache, 2 vs 4, after 25 G and 29 G needles, respectively, were the most frequent postoperative complaints. Mild postdural puncture headache occurred in one eight year old male patient in the 25 G group. In conclusion, lumbar puncture without introducer needle was possible with both needles. The puncture characteristics favoured the 25 G needle. A shorter needle could partly alleviate the difficulties with the 29 G needle.

  15. Intravascular Ultrasound Guidance for Transjugular Intrahepatic Portosystemic Shunt Procedure in a Swine Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kew, Jacqueline; Davies, Roger P.

    2004-01-15

    A new method is described for guiding hepato-portalvenous puncture using a longitudinal side-view intravascular ultrasound(L-IVUS) transducer to assist in the performance of transjugularintrahepatic portosystemic shunt (TIPS) in three Australian swine.Simultaneous L-IVUS with an AcuNav (registered) 5-10 MHz 10 Fr transducer(Acuson Corporation, Mountain View, CA, USA) and fluoroscopy guidance was used to image and monitor the hepatic to portal venous puncture,dilatation of the tract, and deployment of the TIPS stent. Flow through the shunt could be demonstrated with both L-IVUS and angiography. TIPS was successful in all swine. The time for portal vein puncture once the target portal vein was identifiedmore » was reduced at each attempt. The number of portal vein puncture attempts was 2, 1, and 1. No post-procedural complication was evident. L-IVUS-guided TIPS is practical and has the potential to improve safety by permitting simultaneous ultrasound and fluoroscopic imaging of the needle and target vascular structures. This technique allows for a more streamlined approach to TIPS, decreasing the fluoroscopic time (hence,decreasing the radiation exposure to the staff and patient) and anesthetic time. In addition, there are improved safety benefits obviating the need for wedged portography, facilitating avoidance of bile duct and hepatic arterial puncture, and minimizing hepatic injury by decreasing liver capsular puncture and the attendant risks.« less

  16. 3-Dimensional printing guide template assisted percutaneous vertebroplasty: Technical note.

    PubMed

    Li, Jian; Lin, JiSheng; Yang, Yong; Xu, JunChuan; Fei, Qi

    2018-06-01

    Percutaneous vertebroplasty (PVP) is currently considered as an effective treatment for pain caused by acute osteoporotic vertebral compression fracture. Recently, puncture-related complications are increasingly reported. It's important to find a precise technique to reduce the puncture-related complications. We report a case and discussed the novel surgical technique with step-by-step operating procedures, to introduce the precise PVP assisted by a 3-dimensional printing guide template. Based on the preoperative CT scan and infrared scan data, a well-designed individual guide template could be established in a 3-dimensional reconstruction software and printed out by a 3-dimensional printer. In real operation, by matching the guide template to patient's back skin, cement needles' insertion orientation and depth were easily established. Only 14 times C-arm fluoroscopy with HDF mode (total exposure dose was 4.5 mSv) were required during the procedure. The operation took only 17 min. Cement distribution in the vertebral body was very good without any puncture-related complications. Pain was significantly relieved after surgery. In conclusion, the novel precise 3-dimensional printing guide template system may allow (1) comprehensive visualization of the fractured vertebral body and the individual surgical planning, (2) the perfect fitting between skin and guide template to ensure the puncture stability and accuracy, and (3) increased puncture precision and decreased puncture-related complications, surgical time and radiation exposure. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. [The Huber needle as a special cannula for the puncture of implanted ports and pumps--a mistake in multiple variations].

    PubMed

    Müller, H; Zierski, J

    1988-10-03

    Huber-point needles, which are thought to be noncoring, are usually recommended for puncture of implanted drug-delivery devices, such as ports and pumps. Nevertheless, we found occlusion by silicone chips deriving from the silicone inlet septum to be a major technical complication. Electron microscopic investigations demonstrated substantial loss of material from the port membrane after repeated puncture with this type of needle. During an in vitro test, multiple puncture with Huber-type cannulas led to a pressure-dependent leakage of a port after only 150 to 750 insertions of a needle. In addition, the forces necessary for puncture or for withdrawal of the needle were increased with Huber-point needles, possibly due to a coring effect. Another disadvantage of the available port needles is the formation of a hook at the tip, which may lead to additional lesion of the port or pump membrane. In our opinion, resterilization of Huber needles, recommended by the manufactures, is not advisable, because it is well known that safe sterilization of small lumina, e.g., the lumen of the needle, is impossible.

  18. Embolization of an Internal Iliac Artery Aneurysm after Image-Guided Direct Puncture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heye, S., E-mail: sam.heye@uzleuven.be; Vaninbroukx, J.; Daenens, K.

    2012-08-15

    Objective: To evaluate the feasibility, safety, and efficacy of embolization of internal iliac artery aneurysm (IIAA) after percutaneous direct puncture under (cone-beam) computed tomography (CT) guidance. Methods: A retrospective case series of three patients, in whom IIAA not accessible by way of the transarterial route, was reviewed. CT-guided puncture of the IIAA sac was performed in one patient. Two patients underwent puncture of the IIAA under cone-beam CT guidance. Results: Access to the IIAA sac was successful in all three patients. In two of the three patients, the posterior and/or anterior division was first embolized using platinum microcoils. The aneurysmmore » sac was embolized with thrombin in one patient and with a mixture of glue and Lipiodol in two patients. No complications were seen. On follow-up CT, no opacification of the aneurysm sac was seen. The volume of one IIAA remained stable at follow-up, and the remaining two IIAAs decreased in size. Conclusion: Embolization of IIAA after direct percutaneous puncture under cone-beam CT/CT-guidance is feasible and safe and results in good short-term outcome.« less

  19. Blood gases

    MedlinePlus

    ... Test is Performed The test is used to evaluate respiratory diseases and conditions that affect the lungs. ... may include: Bleeding at the puncture site Blood flow problems at puncture site (rare) Bruising at the ...

  20. Recent Advances in Thermoplastic Puncture-Healing Polymers

    NASA Technical Reports Server (NTRS)

    Gordon, K. L.; Working, D. C.; Wise, K. E.; Bogert, P. B.; Britton, S. M.; Topping, C.C.; Smith, J. Y.; Siochi, E. J.

    2009-01-01

    Self-healing materials provide a route for enhanced damage tolerance in materials for aerospace applications. In particular, puncture-healing upon impact has the potential to mitigate significant damage caused by high velocity micrometeoroid impacts. This type of material also has the potential to improve damage tolerance in load bearing structures to enhance vehicle health and aircraft durability. The materials being studied are those capable of instantaneous puncture healing, providing a mechanism for mechanical property retention in lightweight structures. These systems have demonstrated healing capability following penetration of fast moving projectiles -- velocities that range from 9 mm bullets shot from a gun (approx.330 m/sec) to close to micrometeoroid debris velocities of 4800 m/sec. In this presentation, we report on a suite of polymeric materials possessing this characteristic. Figure 1 illustrates the puncture healing concept. Puncture healing in these materials is dependent upon how the combination of a polymer's viscoelastic properties responds to the energy input resulting from the puncture event. Projectile penetration increases the temperature in the vicinity of the impact. Self-healing behavior occurs following puncture, whereby energy must be transferred to the material during impact both elastically and inelastically, thus establishing two requirements for puncture healing to occur: a.) The need for the puncture event to produce a local melt state in the polymer material and b.) The molten material has to have sufficient melt elasticity to snap back and close the hole. 1,2 Previous ballistic testing studies revealed that Surlyn materials warmed up to a temperature approx.98 C during projectile puncture (3 C higher than it s melting temperature). 1,2 The temperature increase produces a localized flow state and the melt elasticity to snap back thus sealing the hole. Table 1 lists the commercially polymers studied here, together with their physical properties. The polymers were selected based on chemical structure, tensile strengths, tensile moduli, glass transition temperature, melting temperatures, and impact strength. The thermal properties of the polymers were characterized by Differential Scanning Calorimetry (DSC) and Dynamic Mechanical Analysis (DMA). Mechanical properties were assessed by a Sintech 2W instron according to ASTM D1708 or D638 at crosshead speeds of 5.08 cm/min. 7.6 cm x 7.6 cm panels of the different materials were prepared and ballistic testing was performed at various temperatures. The panels were shot with a .223 caliber semiautomatic rifle from a distance of 23 meters at various temperatures. Chronographs were used to measure initial and final bullet velocity. Temperatures at the site of impact were measured using a FLIR ThermaCAM S60 thermal camera. A Vision Research model Phantom 9 high speed video camera was used to capture high speed video footage of ballistics testing.

  1. Meteoroid detector

    NASA Technical Reports Server (NTRS)

    Mcmaster, L. R.; Peterson, S. T.; Hughes, F. M. (Inventor)

    1973-01-01

    A meteoroid detector is described which uses, a cold cathode discharge tube with a gas-pressurized cell in space for recording a meteoroid puncture of the cell and for determining the size of the puncture.

  2. Analytic convergence of harmonic metrics for parabolic Higgs bundles

    NASA Astrophysics Data System (ADS)

    Kim, Semin; Wilkin, Graeme

    2018-04-01

    In this paper we investigate the moduli space of parabolic Higgs bundles over a punctured Riemann surface with varying weights at the punctures. We show that the harmonic metric depends analytically on the weights and the stable Higgs bundle. This gives a Higgs bundle generalisation of a theorem of McOwen on the existence of hyperbolic cone metrics on a punctured surface within a given conformal class, and a generalisation of a theorem of Judge on the analytic parametrisation of these metrics.

  3. Postdural puncture headache: a study with 256 Quincke needle.

    PubMed

    Singh, N Ratan; Singh, H Shanti

    2010-02-01

    The incidence of postdural puncture headache, its severity, time of onset and duration following spinal anaesthesia in female subjects using 25 gauge Quincke needles are discussed in this paper. Postdural puncture headache was seen in only 3% of the cases. The headache appeared mainly on the 1st postoperative day and was associated with nausea and vomiting in one case; and it disappeared by the 2nd to 3rd day following administration of mild analgesics and anti-emetics.

  4. Image fusion-guided portal vein puncture during transjugular intrahepatic portosystemic shunt placement.

    PubMed

    Rouabah, K; Varoquaux, A; Caporossi, J M; Louis, G; Jacquier, A; Bartoli, J M; Moulin, G; Vidal, V

    2016-11-01

    The purpose of this study was to assess the feasibility and utility of image fusion (Easy-TIPS) obtained from pre-procedure CT angiography and per-procedure real-time fluoroscopy for portal vein puncture during transjugular intrahepatic portosystemic shunt (TIPS) placement. Eighteen patients (15 men, 3 women) with a mean age of 63 years (range: 48-81 years; median age, 65 years) were included in the study. All patients underwent TIPS placement by two groups of radiologists (one group with radiologists of an experience<3 years and one with an experience≥3 years) using fusion imaging obtained from three-dimensional computed tomography angiography of the portal vein and real-time fluoroscopic images of the portal vein. Image fusion was used to guide the portal vein puncture during TIPS placement. At the end of the procedure, the interventional radiologists evaluated the utility of fusion imaging for portal vein puncture during TIPS placement. Mismatch between three-dimensional computed tomography angiography and real-time fluoroscopic images of the portal vein on image fusion was quantitatively analyzed. Posttreatment CT time, number of the puncture attempts, total radiation exposure and radiation from the retrograde portography were also recorded. Image fusion was considered useful for portal vein puncture in 13/18 TIPS procedures (72%). The mean posttreatment time to obtain fusion images was 16.4minutes. 3D volume rendered CT angiography images was strictly superimposed on direct portography in 10/18 procedures (56%). The mismatch mean value was 0.69cm in height and 0.28cm laterally. A mean number of 4.6 portal vein puncture attempts was made. Eight patients required less than three attempts. The mean radiation dose from retrograde portography was 421.2dGy.cm 2 , corresponding to a mean additional exposure of 19%. Fusion imaging resulting from image fusion from pre-procedural CT angiography is feasible, safe and makes portal puncture easier during TIPS placement. Copyright © 2016 Editions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  5. Ureteroscopy-assisted Percutaneous Kidney Access Made Easy: First Clinical Experience with a Novel Navigation System Using Electromagnetic Guidance (IDEAL Stage 1).

    PubMed

    Lima, Estevao; Rodrigues, Pedro L; Mota, Paulo; Carvalho, Nuno; Dias, Emanuel; Correia-Pinto, Jorge; Autorino, Riccardo; Vilaça, João L

    2017-10-01

    Puncture of the renal collecting system represents a challenging step in percutaneous nephrolithotomy (PCNL). Limitations related to the use of standard fluoroscopic-based and ultrasound-based maneuvers have been recognized. To describe the technique and early clinical outcomes of a novel navigation system for percutaneous kidney access. This was a proof-of-concept study (IDEAL phase 1) conducted at a single academic center. Ten PCNL procedures were performed for patients with kidney stones. Flexible ureterorenoscopy was performed to determine the optimal renal calyx for access. An electromagnetic sensor was inserted through the working channel. Then the selected calyx was punctured with a needle with a sensor on the tip guided by real-time three-dimensional images observed on the monitor. The primary endpoints were the accuracy and clinical applicability of the system in clinical use. Secondary endpoints were the time to successful puncture, the number of attempts for successful puncture, and complications. Ten patients were enrolled in the study. The median age was 47.1 yr (30-63), median body mass index was 22.85kg/m 2 (19-28.3), and median stone size was 2.13cm (1.5-2.5cm). All stones were in the renal pelvis. The Guy's stone score was 1 in nine cases and 2 in one case. All 10 punctures of the collecting system were successfully completed at the first attempt without X-ray exposure. The median time to successful puncture starting from insertion of the needle was 20 s (range 15-35). No complications occurred. We describe the first clinical application of a novel navigation system using real-time electromagnetic sensors for percutaneous kidney access. This new technology overcomes the intrinsic limitations of traditional methods of kidney access, allowing safe, precise, fast, and effective puncture of the renal collecting system. We describe a new technology allowing safe and easy puncture of the kidney without radiation exposure. This could significantly facilitate one of the most challenging steps in percutaneous removal of kidney stones. Copyright © 2017 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  6. Puncture Wounds: First Aid

    MedlinePlus

    ... aid/first-aid-puncture-wounds/basics/ART-20056665 . Mayo Clinic Footer Legal Conditions and Terms Any use of ... Privacy Practices Notice of Nondiscrimination Manage Cookies Advertising Mayo Clinic is a not-for-profit organization and proceeds ...

  7. Lumbar Puncture (Spinal Tap) (For Parents)

    MedlinePlus

    ... specific bacteria growing in the sample, a bacterial culture is sent to the lab and these results ... treatment while waiting for the results of the culture. Risks A lumbar puncture is considered a safe ...

  8. Simple method to set up low eccentricity initial data for moving puncture simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tichy, Wolfgang; Marronetti, Pedro

    2011-01-15

    We introduce two new eccentricity measures to analyze numerical simulations. Unlike earlier definitions these eccentricity measures do not involve any free parameters which makes them easy to use. We show how relatively inexpensive grid setups can be used to estimate the eccentricity during the early inspiral phase. Furthermore, we compare standard puncture data and post-Newtonian data in ADMTT gauge. We find that both use different coordinates. Thus low eccentricity initial momentum parameters for a certain separation measured in ADMTT coordinates are hard to use in puncture data, because it is not known how the separation in puncture coordinates is relatedmore » to the separation in ADMTT coordinates. As a remedy we provide a simple approach which allows us to iterate the momentum parameters until our numerical simulations result in acceptably low eccentricities.« less

  9. Cranial nerve VI palsy after dural-arachnoid puncture.

    PubMed

    Hofer, Jennifer E; Scavone, Barbara M

    2015-03-01

    In this article, we provide a literature review of cranial nerve (CN) VI injury after dural-arachnoid puncture. CN VI injury is rare and ranges in severity from diplopia to complete lateral rectus palsy with deviated gaze. The proposed mechanism of injury is cerebrospinal fluid leakage causing intracranial hypotension and downward displacement of the brainstem. This results in traction on CN VI leading to stretch and neural demyelination. Symptoms may present 1 day to 3 weeks after dural-arachnoid puncture and typically are associated with a postdural puncture (spinal) headache. Resolution of symptoms may take weeks to months. Use of small-gauge, noncutting spinal needles may decrease the risk of intracranial hypotension and subsequent CN VI injury. When ocular symptoms are present, early administration of an epidural blood patch may decrease morbidity or prevent progression of ocular symptoms.

  10. Protective materials with real-time puncture detection capability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hermes, R.E.; Stampfer, J.F.; Valdez-Boyle, L.S.

    1996-08-01

    The protection of workers from chemical, biological, or radiological hazards requires the use of protective materials that can maintain their integrity during use. An accidental puncture in the protective material can result in a significant exposure to the worker. A five ply material has been developed that incorporates two layers of an electrically conductive polymer sandwiched between three layers of a nonconductive polymer. A normally open circuit that is connected between the conductive layers will be closed by puncturing the material with either a conductive or nonconductive object. This can be used to activate an audible alarm or visual beaconmore » to warn the worker of a breach in the integrity of the material. The worker is not connected to the circuit, and the puncture can be detected in real-time, even when caused by a nonconductor.« less

  11. Spinal needle force monitoring during lumbar puncture using fiber Bragg grating force device.

    PubMed

    Ambastha, Shikha; Umesh, Sharath; Dabir, Sundaresh; Asokan, Sundarrajan

    2016-11-01

    A technique for real-time dynamic monitoring of force experienced by a spinal needle during lumbar puncture using a fiber Bragg grating (FBG) sensor is presented. The proposed FBG force device (FBGFD) evaluates the compressive force on the spinal needle during lumbar puncture, particularly avoiding the bending effect on the needle. The working principle of the FBGFD is based on transduction of force experienced by the spinal needle into strain variations monitored by the FBG sensor. FBGFD facilitates external mounting of a spinal needle for its smooth insertion during lumbar puncture without any intervention. The developed FBGFD assists study and analysis of the force required for the spinal needle to penetrate various tissue layers from skin to the epidural space; this force is indicative of the varied resistance offered by different tissue layers for the spinal needle traversal. Calibration of FBGFD is performed on a micro-universal testing machine for 0 to 20 N range with an obtained resolution of 0.021 N. The experimental trials using spinal needles mounted on FBGFD are carried out on a human cadaver specimen with punctures made in the lumbar region from different directions. Distinct forces are recorded when the needle encounters skin, muscle tissue, and a bone in its traversing path. Real-time spinal needle force monitoring using FBGFD may reduce potentially serious complications during the lumbar puncture, such as overpuncturing of tissue regions, by impeding the spinal needle insertion at epidural space.

  12. Ultrasound-guided, minimally invasive, percutaneous needle puncture treatment for tennis elbow.

    PubMed

    Zhu, Jiaan; Hu, Bing; Xing, Chunyan; Li, Jia

    2008-10-01

    This report evaluates the efficacy of percutaneous needle puncture under sonographic guidance in treating lateral epicondylitis (tennis-elbow). Ultrasound-guided percutaneous needle puncture was performed on 76 patients who presented with persistent elbow pain. Under a local anesthetic and sonographic guidance, a needle was advanced into the calcification foci and the calcifications were mechanically fragmented. This was followed by a local injection of 25 mg prednisone acetate and 1% lidocaine. If no calcification was found then multiple punctures were performed followed by local injection of 25 mg prednisone acetate and 1% lidocaine. A visual analog scale (VAS) was used to evaluate the degree of pain pre-and posttreatment at 1 week to 24 weeks. Elbow function improvement and degree of self-satisfaction were also evaluated. Of the 76 patients, 55% were rated with excellent treatment outcome, 32% good, 11% average, and 3% poor. From 3 weeks posttreatment, VAS scores were significantly reduced compared with the pretreatment score (P<0.05) and continued to gradually decline up to 24 weeks posttreatment. Sonography demonstrated that the calcified lesions disappeared completely in 13% of the patients, were reduced in 61% of the patients, and did not change in 26% of the patients. Color Doppler flow signal used to assess hemodynamic changes showed a significant improvement after treatment in most patients. Ultrasound-guided percutaneous needle puncture is an effective and minimally invasive treatment for tennis elbow. Sonography can be used to accurately identify the puncture location and monitor changes.

  13. [Paresthesia and spinal anesthesia for cesarean section: comparison of patient positioning].

    PubMed

    Palacio Abizanda, F J; Reina, M A; Fornet, I; López, A; López López, M A; Morillas Sendín, P

    2009-01-01

    To determine the incidence of paresthesia during lumbar puncture performed with the patient in different positions. A single-blind prospective study of patients scheduled for elective cesarean section, randomized to 3 groups. In group 1 patients were seated in the direction of the long axis of the table, with heels resting on the table. In group 2 they were seated perpendicular to the long axis of the table, with legs hanging from the table. In group 3 they were in left lateral decubitus position. Lumbar punctures were performed with a 27-gauge Whitacre needle. One hundred sixty-eight patients (56 per group) were enrolled. Paresthesia occurred most often in group 3 (P = .009). We observed no differences in blood pressure after patients moved from decubitus position to the assigned position. Nor did we observe between-group differences in blood pressure according to position taken during puncture. Puncture undertaken with the patient seated, heels on the table and knees slightly bent, is associated with a lower incidence of paresthesia than puncture performed with the patient seated, legs hanging from the table. Placing the patient's heels on the table requires hip flexion and leads to anterior displacement of nerve roots in the dural sac. Such displacement would increase the nerve-free zone on the posterior side of the sac, thereby decreasing the likelihood of paresthesia during lumbar puncture. A left lateral decubitus position would increase the likelihood of paresthesia, possibly because the anesthetist may inadvertently not follow the medial line when inserting the needle.

  14. Spinal needle force monitoring during lumbar puncture using fiber Bragg grating force device

    NASA Astrophysics Data System (ADS)

    Ambastha, Shikha; Umesh, Sharath; Dabir, Sundaresh; Asokan, Sundarrajan

    2016-11-01

    A technique for real-time dynamic monitoring of force experienced by a spinal needle during lumbar puncture using a fiber Bragg grating (FBG) sensor is presented. The proposed FBG force device (FBGFD) evaluates the compressive force on the spinal needle during lumbar puncture, particularly avoiding the bending effect on the needle. The working principle of the FBGFD is based on transduction of force experienced by the spinal needle into strain variations monitored by the FBG sensor. FBGFD facilitates external mounting of a spinal needle for its smooth insertion during lumbar puncture without any intervention. The developed FBGFD assists study and analysis of the force required for the spinal needle to penetrate various tissue layers from skin to the epidural space; this force is indicative of the varied resistance offered by different tissue layers for the spinal needle traversal. Calibration of FBGFD is performed on a micro-universal testing machine for 0 to 20 N range with an obtained resolution of 0.021 N. The experimental trials using spinal needles mounted on FBGFD are carried out on a human cadaver specimen with punctures made in the lumbar region from different directions. Distinct forces are recorded when the needle encounters skin, muscle tissue, and a bone in its traversing path. Real-time spinal needle force monitoring using FBGFD may reduce potentially serious complications during the lumbar puncture, such as overpuncturing of tissue regions, by impeding the spinal needle insertion at epidural space.

  15. Therapeutic effects of visual standard channel combined with F4.8 visual puncture super-mini percutaneous nephrolithotomy on multiple renal calculi.

    PubMed

    Cui, Zhenyu; Gao, Yanjun; Yang, Wenzeng; Zhao, Chunli; Ma, Tao; Shi, Xiaoqiang

    2018-01-01

    To evaluate the therapeutic effects of visual standard channel combined with F4.8 visual puncture super-mini percutaneous nephrolithotomy (SMP) on multiple renal calculi. The clinical data of 46 patients with multiple renal calculi treated in Affiliated Hospital of Hebei University from October 2015 to September 2016 were retrospectively analyzed. There were 28 males and 18 females aged from 25 to 65 years old, with an average of 42.6. The stone diameters were 3.0-5.2 cm, (4.3 ± 0.8) cm on average. F4.8 visual puncture-assisted balloon expansion was used to establish a standard channel. After visible stones were removed through nephroscopy combined with ultrasound lithotripsy, the stones of other parts were treated through F4.8 visual puncture SMP with holmium laser. Indices such as the total time of channel establishment, surgical time, decreased value of hemoglobin, phase-I stone clearance rate and surgical complications were summarized. Single standard channel was successfully established in all cases with the assistance of F4.8 visual puncture, of whom 24 were combined with a single microchannel, 16 were combined with double microchannels, and six were combined with three microchannels. All patients were placed with nephrostomy tube which was not placed in the microchannels. Both F5 double J tubes were placed after surgery. The time for establishing a standard channel through F4.8 visual puncture was (6.8 ± 1.8) min, and that for establishing a single F4.8 visual puncture microchannel was (4.5 ± 0.9) min. The surgical time was (92 ± 15) min. The phase-I stone clearance rate was 91.3% (42/46), and the decreased value of hemoglobin was (12.21 ± 2.5) g/L. There were 8 cases of postoperative fever which was relieved after anti-inflammatory treatment. Four cases had 0.5-0.8 cm of stone residue in the lower calyx, and all stones were discharged one month after surgery by in vitro shock wave lithotripsy combined with position nephrolithotomy, without stone streets, delayed bleeding, peripheral organ damage or urethral injury. Combining visual standard channel with F4.8 visual puncture SMP for the treatment of multiple renal calculi had the advantages of reducing the number of large channels, high rate of stone clearance, safety and reliability and mild complications. The established F4.8 visual puncture channel was safer and more accurate.

  16. Development of Needle Insertion Manipulator for Central Venous Catheterization

    NASA Astrophysics Data System (ADS)

    Kobayashi, Yo; Hong, Jaesung; Hamano, Ryutaro; Hashizume, Makoto; Okada, Kaoru; Fujie, Masakatsu G.

    Central venous catheterization is a procedure, which a doctor insert a catheter into the patient’s vein for transfusion. Since there are risks of bleeding from arterial puncture or pneumothorax from pleural puncture. Physicians are strictly required to make needle reach up into the vein and to stop the needle in the middle of vein. We proposed a robot system for assisting the venous puncture, which can relieve the difficulties in conventional procedure, and the risks of complication. This paper reports the design structuring and experimental results of needle insertion manipulator. First, we investigated the relationship between insertion force and angle into the vein. The results indicated that the judgment of perforation using the reaction force is possible in case where the needling angle is from 10 to 20 degree. The experiment to evaluate accuracy of the robot also revealed that it has beyond 0.5 mm accuracy. We also evaluated the positioning accuracy in the ultrasound images. The results displays that the accuracy is beyond 1.0 mm and it has enough for venous puncture. We also carried out the venous puncture experiment to the phantom and confirm our manipulator realized to make needle reach up into the vein.

  17. Seamless data-range change using punctured convolutional codes for time-varying signal-to-noise ratios

    NASA Technical Reports Server (NTRS)

    Feria, Y.; Cheung, K.-M.

    1995-01-01

    In a time-varying signal-to-noise ration (SNR) environment, symbol rate is often changed to maximize data return. However, the symbol-rate change has some undesirable effects, such as changing the transmission bandwidth and perhaps causing the receiver symbol loop to lose lock temporarily, thus losing some data. In this article, we are proposing an alternate way of varying the data rate without changing the symbol rate and, therefore, the transmission bandwidth. The data rate change is achieved in a seamless fashion by puncturing the convolutionally encoded symbol stream to adapt to the changing SNR environment. We have also derived an exact expression to enumerate the number of distinct puncturing patterns. To demonstrate this seamless rate change capability, we searched for good puncturing patterns for the Galileo (14,1/4) convolutional code and changed the data rates by using the punctured codes to match the Galileo SNR profile of November 9, 1997. We show that this scheme reduces the symbol-rate changes from nine to two and provides a comparable data return in a day and a higher symbol SNR during most of the day.

  18. Mycobacterium ulcerans low infectious dose and mechanical transmission support insect bites and puncturing injuries in the spread of Buruli ulcer.

    PubMed

    Wallace, John R; Mangas, Kirstie M; Porter, Jessica L; Marcsisin, Renee; Pidot, Sacha J; Howden, Brian; Omansen, Till F; Zeng, Weiguang; Axford, Jason K; Johnson, Paul D R; Stinear, Timothy P

    2017-04-01

    Addressing the transmission enigma of the neglected disease Buruli ulcer (BU) is a World Health Organization priority. In Australia, we have observed an association between mosquitoes harboring the causative agent, Mycobacterium ulcerans, and BU. Here we tested a contaminated skin model of BU transmission by dipping the tails from healthy mice in cultures of the causative agent, Mycobacterium ulcerans. Tails were exposed to mosquito (Aedes notoscriptus and Aedes aegypti) blood feeding or punctured with sterile needles. Two of 12 of mice with M. ulcerans contaminated tails exposed to feeding A. notoscriptus mosquitoes developed BU. There were no mice exposed to A. aegypti that developed BU. Eighty-eight percent of mice (21/24) subjected to contaminated tail needle puncture developed BU. Mouse tails coated only in bacteria did not develop disease. A median incubation time of 12 weeks, consistent with data from human infections, was noted. We then specifically tested the M. ulcerans infectious dose-50 (ID50) in this contaminated skin surface infection model with needle puncture and observed an ID50 of 2.6 colony-forming units. We have uncovered a biologically plausible mechanical transmission mode of BU via natural or anthropogenic skin punctures.

  19. Seamless Data-Rate Change Using Punctured Convolutional Codes for Time-Varying Signal-to-Noise Ratios

    NASA Astrophysics Data System (ADS)

    Feria, Y.; Cheung, K.-M.

    1994-10-01

    In a time-varying signal-to-noise ratio (SNR) environment, symbol rate is often changed to maximize data return. However, the symbol-rate change has some undesirable effects, such as changing the transmission bandwidth and perhaps causing the receiver symbol loop to lose lock temporarily, thus losing some data. In this article, we are proposing an alternate way of varying the data rate without changing the symbol rate and, therefore, the transmission bandwidth. The data rate change is achieved in a seamless fashion by puncturing the convolutionally encoded symbol stream to adapt to the changing SNR environment. We have also derived an exact expression to enumerate the number of distinct puncturing patterns. To demonstrate this seamless rate-change capability, we searched for good puncturing patterns for the Galileo (14,1/4) convolutional code and changed the data rates by using the punctured codes to match the Galileo SNR profile of November 9, 1997. We show that this scheme reduces the symbol-rate changes from nine to two and provides a comparable data return in a day and a higher symbol SNR during most of the day.

  20. Seamless data-range change using punctured convolutional codes for time-varying signal-to-noise ratios

    NASA Astrophysics Data System (ADS)

    Feria, Y.; Cheung, K.-M.

    1995-02-01

    In a time-varying signal-to-noise ration (SNR) environment, symbol rate is often changed to maximize data return. However, the symbol-rate change has some undesirable effects, such as changing the transmission bandwidth and perhaps causing the receiver symbol loop to lose lock temporarily, thus losing some data. In this article, we are proposing an alternate way of varying the data rate without changing the symbol rate and, therefore, the transmission bandwidth. The data rate change is achieved in a seamless fashion by puncturing the convolutionally encoded symbol stream to adapt to the changing SNR environment. We have also derived an exact expression to enumerate the number of distinct puncturing patterns. To demonstrate this seamless rate change capability, we searched for good puncturing patterns for the Galileo (14,1/4) convolutional code and changed the data rates by using the punctured codes to match the Galileo SNR profile of November 9, 1997. We show that this scheme reduces the symbol-rate changes from nine to two and provides a comparable data return in a day and a higher symbol SNR during most of the day.

  1. Construction of constant curvature punctured Riemann surfaces with particle-scattering interpretation

    NASA Astrophysics Data System (ADS)

    Bilal, Adel; Gervais, Jean-Loup

    A class of punctured constant curvature Riemann surfaces, with boundary conditions similar to those of the Poincaré half plane, is constructed. It is shown to describe the scattering of particle-like objects in two Euclidian dimensions. The associated time delays and classical phase shifts are introduced and connected to the behaviour of the surfaces at their punctures. For each such surface, we conjecture that the time delays are partial derivatives of the phase shift. This type of relationship, already known to be correct in other scattering problems, leads to a general integrability condition concerning the behaviour of the metric in the neighbourhood of the punctures. The time delays are explicitly computed for three punctures, and the conjecture is verified. The result, reexpressed as a product of Riemann zeta-functions, exhibits an intringuing number-theoretic structure: a p-adic product formula holds and one of Ramanujan's identities applies. An ansatz is given for the corresponding exact quantum S-matrix. It is such that the integrability condition is replaced by a finite difference relation only involving the exact spectrum already derived, in the associated Liouville field theory, by Gervais and Neveu.

  2. Laparoscopic Removal of a Large Ovarian Mass Utilizing Planned Trocar Puncture

    PubMed Central

    2012-01-01

    Background: Large cystic ovarian masses pose technical challenges to the laparoscopic surgeon. Removing large, potentially malignant specimens must be done with care to avoid the leakage of cyst fluid into the abdominal cavity. Case: We present the case of a large ovarian cystic mass treated laparoscopically with intentional trocar puncture of the mass to drain and remove the mass. Discussion: Large cystic ovarian masses can be removed laparoscopically with intentional trocar puncture of the mass to facilitate removal without leakage of cyst fluid. PMID:22906344

  3. Significant Improvement of Puncture Accuracy and Fluoroscopy Reduction in Percutaneous Transforaminal Endoscopic Discectomy With Novel Lumbar Location System: Preliminary Report of Prospective Hello Study.

    PubMed

    Fan, Guoxin; Guan, Xiaofei; Zhang, Hailong; Wu, Xinbo; Gu, Xin; Gu, Guangfei; Fan, Yunshan; He, Shisheng

    2015-12-01

    Prospective nonrandomized control study.The study aimed to investigate the implication of the HE's Lumbar LOcation (HELLO) system in improving the puncture accuracy and reducing fluoroscopy in percutaneous transforaminal endoscopic discectomy (PTED).Percutaneous transforaminal endoscopic discectomy is one of the most popular minimally invasive spine surgeries that heavily depend on repeated fluoroscopy. Increased fluoroscopy will induce higher radiation exposure to surgeons and patients. Accurate puncture in PTED can be achieved by accurate preoperative location and definite trajectory.The HELLO system mainly consists of self-made surface locator and puncture-assisted device. The surface locator was used to identify the exact puncture target and the puncture-assisted device was used to optimize the puncture trajectory. Patients who had single L4/5 or L5/S1 lumbar intervertebral disc herniation and underwent PTED were included the study. Patients receiving the HELLO system were assigned in Group A, and those taking conventional method were assigned in Group B. Study primary endpoint was puncture times and fluoroscopic times, and the secondary endpoint was location time and operation time.A total of 62 patients who received PTED were included in this study. The average age was 45.35 ± 8.70 years in Group A and 46.61 ± 7.84 years in Group B (P = 0.552). There were no significant differences in gender, body mass index, conservative time, and surgical segment between the 2 groups (P > 0.05). The puncture times were 1.19 ± 0.48 in Group A and 6.03 ± 1.87 in Group B (P < 0.001). The fluoroscopic times were 14.03 ± 2.54 in Group A and 25.19 ± 4.28 in Group B (P < 0.001). The preoperative location time was 4.67 ± 1.41 minutes in Group A and 6.98 ± 0.94 minutes in Group B (P < 0.001). The operation time was 79.42 ± 10.15 minutes in Group A and 89.65 ± 14.06 minutes in Group B (P = 0.002). The hospital stay was 2.77 ± 0.95 days in Group A and 2.87 ± 1.02 days in Group B (P = 0.702). There were no significant differences in the complication rate between the 2 groups (P = 0.386).The highlight of HELLO system is accurate preoperative location and definite trajectory. This preliminary report indicated that the HELLO system significantly improves the puncture accuracy of PTED and reduces the fluoroscopic times, preoperative location time, as well as operation time. (ChiCTR-ICR-15006730).

  4. Needle puncture in rabbit functional spinal units alters rotational biomechanics.

    PubMed

    Hartman, Robert A; Bell, Kevin M; Quan, Bichun; Nuzhao, Yao; Sowa, Gwendolyn A; Kang, James D

    2015-04-01

    An in vitro biomechanical study for rabbit lumbar functional spinal units (FSUs) using a robot-based spine testing system. To elucidate the effect of annular puncture with a 16 G needle on mechanical properties in flexion/extension, axial rotation, and lateral bending. Needle puncture of the intervertebral disk has been shown to alter mechanical properties of the disk in compression, torsion, and bending. The effect of needle puncture in FSUs, where intact spinal ligaments and facet joints may mitigate or amplify these changes in the disk, on spinal motion segment stability subject to physiological rotations remains unknown. Rabbit FSUs were tested using a robot testing system whose force/moment and position precision were assessed to demonstrate system capability. Flexibility testing methods were developed by load-to-failure testing in flexion/extension, axial rotation, and lateral bending. Subsequent testing methods were used to examine a 16 G needle disk puncture and No. 11 blade disk stab (positive control for mechanical disruption). Flexibility testing was used to assess segmental range-of-motion (degrees), neutral zone stiffness (N m/degrees) and width (degrees and N m), and elastic zone stiffness before and after annular injury. The robot-based system was capable of performing flexibility testing on FSUs-mean precision of force/moment measurements and robot system movements were <3% and 1%, respectively, of moment-rotation target values. Flexibility moment targets were 0.3 N m for flexion and axial rotation and 0.15 N m for extension and lateral bending. Needle puncture caused significant (P<0.05) changes only in flexion/extension range-of-motion and neutral zone stiffness and width (N m) compared with preintervention. No. 11 blade-stab significantly increased range-of-motion in all motions, decreased neutral zone stiffness and width (N m) in flexion/extension, and increased elastic zone stiffness in flexion and lateral bending. These findings suggest that disk puncture and stab can destabilize FSUs in primary rotations.

  5. Hollow mandrin facilitates external ventricular drainage placement.

    PubMed

    Heese, O; Regelsberger, J; Kehler, U; Westphal, M

    2005-07-01

    Placement of ventricular catheters is a routine procedure in neurosurgery. Ventricle puncture is done using a flexible ventricular catheter stabilised by a solid steel mandrin in order to improve stability during brain penetration. A correct catheter placement is confirmed after removing the solid steel mandrin by observation of cerebrospinal fluid (CSF) flow out of the flexible catheter. Incorrect placement makes further punctures necessary. The newly developed device allows CSF flow observation during the puncture procedure and in addition precise intracranial pressure (ICP) measurement. The developed mandrin is hollow with a blunt tip. On one side 4-5 small holes with a diameter of 0.8 mm are drilled corresponding exactly with the holes in the ventricular catheter, allowing CSF to pass into the hollow mandrin as soon as the ventricle is reached. By connecting a small translucent tube at the distal portion of the hollow mandrin ICP can be measured without loss of CSF. The system has been used in 15 patients with subarachnoid haemorrhage (SAH) or intraventricular haemeorrhage (IVH) and subsequent hydrocephalus. The new system improved the external ventricular drainage implantation procedure. In all 15 patients catheter placement was correct. ICP measurement was easy to perform immediately at ventricle puncture. In 4 patients at puncture no spontaneous CSF flow was observed, therefore by connecting a syringe and gentle aspiration of CSF correct placement was confirmed in this unexpected low pressure hydrocephalus. Otherwise by using the conventional technique further punctures would have been necessary. Advantages of the new technique are less puncture procedures with a lower risk of damage to neural structures and reduced risk of intracranial haemorrhages. Implantation of the ventricular catheter to far into the brain can be monitored and this complication can be overcome. Using the connected pressure monitoring tube an exact measurement of the opening intracranial pressure can be obtained performed without losing CSF.

  6. [Comparison of the intracranial pressure value in patients with hypertensive intracerebral hemorrhage treated with traditional craniotomy and puncture drainage].

    PubMed

    Song, Shao-jun; Fei, Zhou; Zhang, Xiang

    2003-09-01

    To compare the difference of intracranial pressure (ICP) in patients with hypertensive intracerebral hemorrhage (HICH) treated with two surgical procedures, traditional craniotomy and puncture drainage. One hundred and twelve cases with HICH were randomly divided into two groups. In one group, 60 patients were operated by traditional craniotomy and in another group, 52 cases by puncture drainage and urokinase treatment. In the meantime, ICP was monitored by placing catheter in lateral ventricle on the contralateral side of the hemorrhage. ICP values were recorded after operation at once, at 24 hours, 72 hours and 1 week. Although all the patients showed increased ICP, the increasing degree in patients treated with traditional craniotomy had lower ICP values (P<0.05 or P<0.01). Traditional craniotomy has advantages over puncture drainage for patients with HICH at least with respect to decreasing ICP.

  7. Is there a difference in postdural puncture headache after continuous spinal anesthesia with 28G microcatheters compared with punctures with 22G Quincke or Sprotte spinal needles?

    PubMed

    Lux, Eberhard Albert; Althaus, Astrid

    2014-01-01

    In this retrospective study, the question was raised and answered whether the rate of postdural puncture headache (PDPH) after continuous spinal anesthesia with a 28G microcatheter varies using a Quincke or a Sprotte needle. The medical records of all patients with allogenic joint replacement of the knee or hip or arthroscopic surgery of the knee joint undergoing continuous spinal anesthesia with a 22G Quincke (n=1,212) or 22G Sprotte needle (n=377) and a 28G microcatheter during the past 6 years were reviewed. We obtained the approval of the ethical committee. The rates of PDPH were statistically not different between both groups: 1.5% of patients developed PDPH after dura puncture with a Quincke needle and 2.1% with a Sprotte needle in women and men.

  8. Is there a difference in postdural puncture headache after continuous spinal anesthesia with 28G microcatheters compared with punctures with 22G Quincke or Sprotte spinal needles?

    PubMed Central

    Lux, Eberhard Albert; Althaus, Astrid

    2014-01-01

    In this retrospective study, the question was raised and answered whether the rate of postdural puncture headache (PDPH) after continuous spinal anesthesia with a 28G microcatheter varies using a Quincke or a Sprotte needle. The medical records of all patients with allogenic joint replacement of the knee or hip or arthroscopic surgery of the knee joint undergoing continuous spinal anesthesia with a 22G Quincke (n=1,212) or 22G Sprotte needle (n=377) and a 28G microcatheter during the past 6 years were reviewed. We obtained the approval of the ethical committee. The rates of PDPH were statistically not different between both groups: 1.5% of patients developed PDPH after dura puncture with a Quincke needle and 2.1% with a Sprotte needle in women and men. PMID:25419159

  9. Complete prevention of blood loss with self-sealing haemostatic needles

    NASA Astrophysics Data System (ADS)

    Shin, Mikyung; Park, Sung-Gurl; Oh, Byung-Chang; Kim, Keumyeon; Jo, Seongyeon; Lee, Moon Sue; Oh, Seok Song; Hong, Seon-Hui; Shin, Eui-Cheol; Kim, Ki-Suk; Kang, Sun-Woong; Lee, Haeshin

    2017-01-01

    Bleeding is largely unavoidable following syringe needle puncture of biological tissues and, while inconvenient, this typically causes little or no harm in healthy individuals. However, there are certain circumstances where syringe injections can have more significant side effects, such as uncontrolled bleeding in those with haemophilia, coagulopathy, or the transmission of infectious diseases through contaminated blood. Herein, we present a haemostatic hypodermic needle able to prevent bleeding following tissue puncture. The surface of the needle is coated with partially crosslinked catechol-functionalized chitosan that undergoes a solid-to-gel phase transition in situ to seal punctured tissues. Testing the capabilities of these haemostatic needles, we report complete prevention of blood loss following intravenous and intramuscular injections in animal models, and 100% survival in haemophiliac mice following syringe puncture of the jugular vein. Such self-sealing haemostatic needles and adhesive coatings may therefore help to prevent complications associated with bleeding in more clinical settings.

  10. An evaluation of the Johnson-Cook model to simulate puncture of 7075 aluminum plates.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Corona, Edmundo; Orient, George Edgar

    The objective of this project was to evaluate the use of the Johnson-Cook strength and failure models in an adiabatic finite element model to simulate the puncture of 7075- T651 aluminum plates that were studied as part of an ASC L2 milestone by Corona et al (2012). The Johnson-Cook model parameters were determined from material test data. The results show a marked improvement, in particular in the calculated threshold velocity between no puncture and puncture, over those obtained in 2012. The threshold velocity calculated using a baseline model is just 4% higher than the mean value determined from experiment, inmore » contrast to 60% in the 2012 predictions. Sensitivity studies showed that the threshold velocity predictions were improved by calibrating the relations between the equivalent plastic strain at failure and stress triaxiality, strain rate and temperature, as well as by the inclusion of adiabatic heating.« less

  11. Optical analysis of suspended particles in the cerebrospinal fluid obtained by puncture from patients diagnosed with the disorders of cerebrospinal fluid (CSF) circulation

    NASA Astrophysics Data System (ADS)

    Staroń, Waldemar; Herbowski, Leszek; Gurgul, Henryk

    2007-04-01

    The goal of the work was to determine the values of cumulative parameters of the cerebrospinal fluid. Values of the parameters characterise statistical cerebrospinal fluid obtained by puncture from the patients diagnosed due to suspicion of normotensive hydrocephalus. The cerebrospinal fluid taken by puncture for the routine examinations carried out at the patients suspected of normotensive hydrocephalus was analysed. In the paper there are presented results of examinations of several dozens of puncture samples of the cerebrospinal fluid coming from various patients. Each sample was examined under the microscope and photographed in 20 randomly chosen places. On the basis of analysis of the pictures showing the area of 100 x 100μm, the selected cumulative parameters such as count, numerical density, field area and field perimeter were determined for each sample. Then the average value of the parameters was determined as well.

  12. Surgical navigation in urology: European perspective.

    PubMed

    Rassweiler, Jens; Rassweiler, Marie-Claire; Müller, Michael; Kenngott, Hannes; Meinzer, Hans-Peter; Teber, Dogu

    2014-01-01

    Use of virtual reality to navigate open and endoscopic surgery has significantly evolved during the last decade. Current status of seven most interesting projects inside the European Association of Urology section of uro-technology is summarized with review of literature. Marker-based endoscopic tracking during laparoscopic radical prostatectomy using high-definition technology reduces positive margins. Marker-based endoscopic tracking during laparoscopic partial nephrectomy by mechanical overlay of three-dimensional-segmented virtual anatomy is helpful during planning of trocar placement and dissection of renal hilum. Marker-based, iPAD-assisted puncture of renal collecting system shows more benefit for trainees with reduction of radiation exposure. Three-dimensional laser-assisted puncture of renal collecting system using Uro-Dyna-CT realized in an ex-vivo model enables minimal radiation time. Electromagnetic tracking for puncture of renal collecting system using a sensor at the tip of ureteral catheter worked in an in-vivo model of porcine ureter and kidney. Attitude tracking for ultrasound-guided puncture of renal tumours by accelerometer reduces the puncture error from 4.7 to 1.8 mm. Feasibility of electromagnetic and optical tracking with the da Vinci telemanipulator was shown in vitro as well as using in-vivo model of oesophagectomy. Target registration error was 11.2 mm because of soft-tissue deformation. Intraoperative navigation is helpful during percutaneous puncture collecting system and biopsy of renal tumour using various tracking techniques. Early clinical studies demonstrate advantages of marker-based navigation during laparoscopic radical prostatectomy and partial nephrectomy. Combination of different tracking techniques may further improve this interesting addition to video-assisted surgery.

  13. Emergency cricothyrotomy-a comparative study of different techniques in human cadavers.

    PubMed

    Schober, Patrick; Hegemann, Martina C; Schwarte, Lothar A; Loer, Stephan A; Noetges, Peter

    2009-02-01

    Emergency cricothyrotomy is the final lifesaving option in "cannot intubate-cannot ventilate" situations. Fast, efficient and safe management is indispensable to reestablish oxygenation, thus the quickest, most reliable and safest technique should be used. Several cricothyrotomy techniques exist, which can be grouped into two categories: anatomical-surgical and puncture. We studied success rate, tracheal tube insertion time and complications of different techniques, including a novel cricothyrotomy scissors technique in human cadavers. Sixty-three inexperienced health care providers were randomly assigned to apply either an anatomical-surgical technique (standard surgical technique, n=18; novel cricothyrotomy scissors technique, n=14) or a puncture technique (catheter-over-needle technique, n=17; wire-guided technique, n=14). Airway access was almost always successful with the anatomical-surgical techniques (success rate in standard surgical group 94%, scissors group 100%). In contrast, the success rate was smaller (p<0.05) with the puncture techniques (catheter-over-needle group 82%, wire-guided technique 71%). Tracheal tube insertion time was faster overall (p<0.05) with anatomical-surgical techniques (standard surgical 78s [54-135], novel cricothyrotomy scissors technique 60s [42-82]; median [IQR]) than with puncture techniques (catheter-over-needle technique 74s [48-145], wire-guided technique 135s [116-307]). We observed fewer complications with anatomical-surgical techniques than with puncture techniques (p<0.001). In inexperienced health care personnel, anatomical-surgical techniques showed a higher success rate, a faster tracheal tube insertion time and a lower complication rate compared with puncture techniques, suggesting that they may be the techniques of choice in emergencies.

  14. Simulation and training of lumbar punctures using haptic volume rendering and a 6DOF haptic device

    NASA Astrophysics Data System (ADS)

    Färber, Matthias; Heller, Julika; Handels, Heinz

    2007-03-01

    The lumbar puncture is performed by inserting a needle into the spinal chord of the patient to inject medicaments or to extract liquor. The training of this procedure is usually done on the patient guided by experienced supervisors. A virtual reality lumbar puncture simulator has been developed in order to minimize the training costs and the patient's risk. We use a haptic device with six degrees of freedom (6DOF) to feedback forces that resist needle insertion and rotation. An improved haptic volume rendering approach is used to calculate the forces. This approach makes use of label data of relevant structures like skin, bone, muscles or fat and original CT data that contributes information about image structures that can not be segmented. A real-time 3D visualization with optional stereo view shows the punctured region. 2D visualizations of orthogonal slices enable a detailed impression of the anatomical context. The input data consisting of CT and label data and surface models of relevant structures is defined in an XML file together with haptic rendering and visualization parameters. In a first evaluation the visible human male data has been used to generate a virtual training body. Several users with different medical experience tested the lumbar puncture trainer. The simulator gives a good haptic and visual impression of the needle insertion and the haptic volume rendering technique enables the feeling of unsegmented structures. Especially, the restriction of transversal needle movement together with rotation constraints enabled by the 6DOF device facilitate a realistic puncture simulation.

  15. Information computer program for laser therapy and laser puncture

    NASA Astrophysics Data System (ADS)

    Badovets, Nadegda N.; Medvedev, Andrei V.

    1995-03-01

    An informative computer program containing laser therapy and puncture methods has been developed. It was used successfully in connection with the compact Russian medical laser apparatus HELIOS-O1M in laser treatment and the education process.

  16. [Incidence of postmyelography syndrome and postmyelography complaints after lumbar puncture with the Sprotte pencil-like needle in comparison with the Quincke needle].

    PubMed

    Fox, R G; Reiche, W; Kiefer, M; Hagen, T; Huber, G

    1996-11-01

    Myelography in combination with a postmyelography CT is an important presurgical examination because of its excellent visualisation of the disc, the bone and the contrast-filled dura. Side effects after myelography can be observed in up to 50% of patients. The pathophysiological mechanism is thought to be increased cerebrospinal fluid leakage at the puncture site. Since the introduction by Sprotte in 1979 of the pencil-point needle, a modification of Whitacre's needle, fewer complaints after lumbar puncture have been reported. The aim of the study was to examine the influence of two types of needle points and the temperature (37 degrees C vs 21 degrees C) of the contrast medium (CM; iotrolan, Isovist) on the incidence of side effects of lumbar puncture for myelography. In a prospective randomized trial the incidence of complaints after lumbar puncture with intrathecal CM application was evaluated by the use of a 21-G pencil-point needle as modified by Sprotte compared to our usual 22-G needle with a Quincke bevel. Some 412 patients (201 female, 211 male; mean age 54.05 +/- 7.4 years) were investigated. Directly after examination and 1. 3 and 5 days later the patients were questioned about complaints (headache, neck stiffness nausea, vomiting, buzzing in the ear and dizziness). The results were tested by the chi square test. A significantly lower incidence of complaints was seen after lumbar puncture with the pencil-point needle/Quincke needle (headache: 6.3%/18.9%, P < 0.0001; headache lasting 3 days: 0.5%/7.8%, P < 0.0001; headache lasting 5 days: 0%/2.4%, P = 0.0305; nausea: 0%/4.9%, P = 0.0009; vomiting: 0%/3.4%, P = 0.0009; dizziness: 0%/3.4%, P = 0.0074; neck stiffness: 0%/3.4%, P = 0.0074). The temperature of the CM had no influence on the complaints. No influence was seen on the quality of the myelogram. No relation to sex and age was found. Complaints after lumbar puncture and myelography are caused by the cerebrospinal fluid leakage at the puncture site. The incidence of side effects related to this leakage can be reduced by using a pencil-point needle. The temperature of the CM has no influence on the complaints.

  17. Epidural blood patching for preventing and treating post-dural puncture headache.

    PubMed

    Sudlow, C; Warlow, C

    2002-01-01

    Dural puncture is a common procedure, but leakage of CSF from the resulting dural defect may cause postural headache after the procedure, and this can be disabling. Injecting an epidural blood patch around the site of the defect may stop this leakage, and so may have a role in preventing or treating post dural puncture headache. To assess the possible benefits and harms of epidural blood patching in both the prevention and the treatment of post-dural puncture headache. We searched the Cochrane Controlled Trials Register (Cochrane Library, Issue 4, 2000), MEDLINE (January 1994 to December 1998), and EMBASE (January 1980 to December 1998). We also searched the reference lists of relevant articles identified electronically, and asked both the authors of all included trials and colleagues with an interest in this area to let us know of any other potentially relevant studies not already identified. Date of last search: December 2000. We sought all properly randomised, unconfounded trials that compared epidural blood patch versus no epidural blood patch in the prevention or treatment of post-dural puncture headache among all types of patients undergoing dural puncture for any reason. The primary outcome of effectiveness was postural headache. One reviewer extracted details of trial methodology and outcome data from the reports of all trials considered eligible for inclusion. We invited the authors of all such trials both to check the information extracted and to provide any details that were unavailable in the published reports. Intention-to-treat analyses were performed using the Peto O-E method. Information about adverse effects (post-dural puncture backache, epidural infection and lower limb paraesthesia) was also extracted. Three trials (77 patients) were eligible for inclusion. Methodological details were generally incomplete. Although the results of our analyses suggested that both prophylactic and therapeutic epidural blood patching may be of benefit, the very small numbers of patients and outcome events, as well as uncertainties about trial methodology, precluded reliable assessments of the potential benefits and harms of this intervention. Further, adequately powered, randomised trials (including at least a few hundred patients) are required before reliable conclusions can be drawn about the role of epidural blood patching in the prevention and treatment of post-dural puncture headache.

  18. Unexpected rare complication of the facial paralysis in a patient with an antrochoanal polyp following canine fossa puncture.

    PubMed

    Kim, Ah-Young; Choi, Myoung Su

    2015-05-14

    Canine fossa puncture (CFP) combined with endoscopic sinus surgery is a simple and effective method for treating antrochoanal polyps, particularly those that originate in the anterior, inferior or medial aspect of the antrum. Several complications can occur following CFP, including facial paraesthesia and dental numbness. However, facial palsy is extremely rare after CFP. We postulated that a possible mechanism of facial palsy is pressure injury to the soft tissues adjacent to the puncture site, which can damage the buccal branch of the facial nerve during CFP. 2015 BMJ Publishing Group Ltd.

  19. Successful treatment of direct carotid-cavernous fistula in a patient with Ehlers-Danlos syndrome type IV without arterial puncture: the transvenous triple-overlay embolization (TAILOREd) technique.

    PubMed

    Huynh, Thien J; Morton, Ryan P; Levitt, Michael R; Ghodke, Basavaraj V; Wink, Onno; Hallam, Danial K

    2017-08-18

    We report successful transvenous treatment of direct carotid-cavernous fistula in a patient with Ehlers-Danlos syndrome type IV using a novel triple-overlay embolization (TAILOREd) technique without the need for arterial puncture, which is known to be highly risky in this patient group. The TAILOREd technique allowed for successful treatment using preoperative MR angiography as a three-dimensional overlay roadmap combined with cone beam CT and live fluoroscopy, precluding the need for an arterial puncture. 2017 BMJ Publishing Group Ltd.

  20. Difficulties in spinal needle use. Insertion characteristics and failure rates associated with 25-, 27- and 29-gauge Quincke-type spinal needles.

    PubMed

    Tarkkila, P; Huhtala, J; Salminen, U

    1994-08-01

    The effect of different size (25-, 27- and 29-gauge) Quincke-type spinal needles on the incidence of insertion difficulties and failure rates was investigated in a randomised, prospective study with 300 patients. The needle size was randomised but the insertion procedure was standardised. The time to achieve dural puncture was significantly longer with the 29-gauge spinal needle compared with the larger bore needles and was due to the greater flexibility of the thin needle. However, the difference was less than 1 min and cannot be considered clinically significant. There were no significant differences between groups in the number of insertion attempts or failures and the same sensory level of analgesia was reached with all the needle sizes studied. Postoperatively, no postdural puncture headaches occurred in the 29-gauge spinal needle group, whilst in the 25- and 27-gauge needle groups, the postdural puncture headache rates were 7.4% and 2.1% respectively. The incidence of backache was similar in all study groups. We conclude that dural puncture with a 29-gauge spinal needle is clinically as easy as with larger bore needles and its use is indicated in patients who have a high risk of postdural puncture headache.

  1. Effect of system compliance on crack nucleation in soft materials

    NASA Astrophysics Data System (ADS)

    Rattan, Shruti; Crosby, Alfred

    Puncture mechanics in soft materials is critical for the development of new surgical instruments, robot assisted-surgery as well as new materials used in personal protective equipment. However, analytical techniques to study this important deformation process are limited. We have previously described a simple experimental method to study the resistive forces and failure of a soft gel being indented with a small tip needle. We showed that puncture stresses can reach two orders of magnitude greater than the material modulus and that the force response is insensitive to the geometry of the indenter at large indentation depths. Currently, we are examining the influence of system compliance on crack nucleation (e.g. puncture) in soft gels. It is well known that system compliance influences the peak force in adhesion and traditional fracture experiments; however, its influence on crack nucleation is unresolved. We find that as the system becomes more compliant, lower peak forces required to puncture a gel of certain stiffness with the same indenter were measured. We are developing scaling relationships to relate the peak puncture force and system compliance. Our findings introduce new questions with regard to the possibility of intrinsic materials properties related to the critical stress and energy for crack nucleation in soft materials.

  2. On Railroad Tank Car Puncture Performance: Part II - Estimating Metrics

    DOT National Transportation Integrated Search

    2016-04-12

    This paper is the second in a two-part series on the puncture performance of railroad tank cars carrying hazardous materials in the event of an accident. Various metrics are often mentioned in the open literature to characterize the structural perfor...

  3. On Railroad Tank Car Puncture Performance: Part I - Considering Metrics

    DOT National Transportation Integrated Search

    2016-04-12

    This paper is the first in a two-part series on the puncture performance of railroad tank cars carrying hazardous materials in the event of an accident. Various metrics are often mentioned in the open literature to characterize the structural perform...

  4. Detailed puncture analyses tank cars : analysis of different impactor threats and impact conditions.

    DOT National Transportation Integrated Search

    2013-03-01

    There has been significant research in recent years to analyze and improve the impact behavior and puncture resistance of railroad tank cars. Much of this research has been performed using detailed nonlinear finite element analyses supported by full ...

  5. [Special cannulas for the puncture of implanted catheter port systems].

    PubMed

    Haindl, H; Müller, H

    1989-04-01

    The Huber-Point cannula is generally recommended for portal puncture. Two comparative studies are published that show no advantage in using Huber-point cannulas. This has been verified by technical investigations. A new type of non-coring cannula is described.

  6. New EU ETS Phase 4 rules temporarily puncture waterbed

    NASA Astrophysics Data System (ADS)

    Perino, Grischa

    2018-04-01

    The new rules of the EU ETS will fundamentally change its character. The long-term cap on emissions will become a function of past and future market outcomes, temporarily puncturing the waterbed and having retroactive impacts on GHG abatement from overlapping policies.

  7. The aeromedical assessment of human systolic and diastolic blood-pressure transients without direct arterial puncture.

    DOT National Transportation Integrated Search

    1966-05-01

    A system for virtually continuous measurement of both systolic and diatolic blood pressures without recourse to direct arterial puncture has been effected by the modification of already existing standard equipment. This system entails the measurement...

  8. Microneedle arrays allow lower microbial penetration than hypodermic needles in vitro.

    PubMed

    Donnelly, Ryan F; Singh, Thakur Raghu Raj; Tunney, Michael M; Morrow, Desmond I J; McCarron, Paul A; O'Mahony, Conor; Woolfson, A David

    2009-11-01

    In this study we determined, for the first time, the ability of microorganisms to traverse microneedle-induced holes using two different in vitro models. When employing Silescol membranes, the numbers of Candida albicans, Pseudomonas aeruginosa and Staphylococcus epidermidis crossing the membranes were an order of magnitude lower when the membranes were punctured by microneedles rather than a 21G hypodermic needle. Apart from the movement of C. albicans across hypodermic needle-punctured membranes, where 40.2% of the microbial load on control membranes permeated the barrier over 24 h, the numbers of permeating microorganisms was less than 5% of the original microbial load on control membranes. Experiments employing excised porcine skin and radiolabelled microorganisms showed that the numbers of microorganisms penetrating skin beyond the stratum corneum were approximately an order of magnitude greater than the numbers crossing Silescol membranes in the corresponding experiments. Approximately 10(3) cfu of each microorganism adhered to hypodermic needles during insertion. The numbers of microorganisms adhering to MN arrays were an order of magnitude higher in each case. We have shown here that microneedle puncture resulted in significantly less microbial penetration than did hypodermic needle puncture and that no microorganisms crossed the viable epidermis in microneedle-punctured skin, in contrast to needle-punctured skin. Given the antimicrobial properties of skin, it is, therefore, likely that application of microneedle arrays to skin in an appropriate manner would not cause either local or systemic infection in normal circumstances in immune-competent patients. In supporting widespread clinical use of microneedle-based delivery systems, appropriate animal studies are now needed to conclusively demonstrate this in vivo. Safety in patients will be enhanced by aseptic or sterile manufacture and by fabricating microneedles from self-disabling materials (e.g. dissolving or biodegradable polymers) to prevent inappropriate or accidental reuse.

  9. Assessment of Injuries Caused by Anastrepha fraterculus (Wied.) (Diptera: Tephritidae) on the Incidence of Bunch Rot Diseases in Table Grape.

    PubMed

    Machota, R; Bortoli, L C; Cavalcanti, F R; Botton, M; Grützmacher, A D

    2016-08-01

    Anastrepha fraterculus (Wied.) is the main insect pest of table grapes (Vitis vinifera) in the Southern Region of Brazil. In this study, we aimed to investigate the effect of fruit puncturing by adult females and larval infestation by A. fraterculus on the occurrence of bunch rot disease in the grape (cultivar "Itália") by evaluating grapes (a) punctured for oviposition by females of A. fraterculus, sterilized in laboratory with novaluron (40 mg L(-1)) and further spray-inoculated separately with Botrytis cinerea (1 × 10(6) conidia mL(-1)), Glomerella cingulata (1 × 10(6) conidia mL(-1)), and bacteria and yeast that cause sour rot (1 × 10(5) cells mL(-1)), (b) grapes punctured for oviposition by non-sterilized females with pathogen spraying, (c) grapes with mechanical wounds and pathogen spraying, (d) grapes with no wounds and with pathogen spraying, (e) grapes punctured for oviposition by A. fraterculus chemically sterilized in laboratory with novaluron, (f) grapes punctured for oviposition by A. fraterculus non-sterilized in laboratory with novaluron, (g) grapes with mechanical wounds, and (h) grapes with no sterilization or pathogen spraying. Our data indicated that the mechanical and oviposition wounds caused by A. fraterculus increased the percentage of grapes infected by B. cinerea, G. cingulata, and microorganisms of acid rot. The grape puncturing by A. fraterculus and the mechanical wound allows the penetration of B. cinerea and microorganisms leading to acid rot. We conclude that the fruit fly A. fraterculus may facilitate phytopathogens penetration leading to bunch rots in the table grape Itália.

  10. Puncture mechanics of cnidarian cnidocysts: a natural actuator

    PubMed Central

    Oppegard, Shawn C; Anderson, Peter A; Eddington, David T

    2009-01-01

    Background Cnidocysts isolated from cnidarian organisms are attractive as a drug-delivery platform due to their fast, efficient delivery of toxins. The cnidocyst could be utilized as the means to deliver therapeutics in a wearable drug-delivery patch. Cnidocysts have been previously shown to discharge upon stimulation via electrical, mechanical, and chemical pathways. Cnidocysts isolated from the Portuguese Man O' War jellyfish (Physalia physalis) are attractive for this purpose because they possess relatively long threads, are capable of puncturing through hard fish scales, and are stable for years. Results As a first step in using cnidocysts as a functional component of a drug delivery system, the puncture mechanics of the thread were characterized. Tentacle-contained cnidocysts were used as a best-case scenario due to physical immobilization of the cnidocysts within the tentacle. Ex vivo tentacle-contained cnidocysts from Physalia possessed an elastic modulus puncture threshold of approximately 1-2 MPa, based on puncture tests of materials with a gamut of hardness. Also, a method for inducing discharge of isolated cnidocysts was found, utilizing water as the stimulant. Preliminary lectin-binding experiments were performed using fluorophore-conjugated lectins as a possible means to immobilize the isolated cnidocyst capsule, and prevent reorientation upon triggering. Lectins bound homogeneously to the surface of the capsule, suggesting the lectins could be used for cnidocyst immobilization but not orientation. Conclusion Cnidocysts were found to puncture materials up to 1 MPa in hardness, can be discharged in a dry state using water as a stimulant, and bind homogeneously to lectins, a potential means of immobilization. The information gained from this preliminary work will aid in determining the materials and design of the patch that could be used for drug delivery. PMID:19785761

  11. Relationships of abscised cotton fruit to boll weevil (Coleoptera: Curculionidae) feeding, oviposition, and development.

    PubMed

    Showler, Allan T

    2008-02-01

    Abscised cotton, Gossypium hirsutum L., fruit in field plots planted at different times were examined to assess adult boll weevil, Anthonomus grandis grandis Boheman (Coleoptera: Curculionidae), use of squares and bolls during 2002 and 2003 in the Lower Rio Grande Valley of Texas. Although boll abscission is not necessarily related to infestation, generally more bolls abscised than squares and abundances of fallen bolls were not related to the planting date treatments. During 2003, fallen squares were most abundant in the late-planted treatment. Although large squares (5.5-8-mm-diameter) on the plant are preferred for boll weevil oviposition, diameter of abscised squares is not a reliable measurement because of shrinkage resulting from desiccation and larval feeding. Fallen feeding-punctured squares and bolls were most abundant in late plantings but differences between fallen feeding-punctured squares versus fallen feeding-punctured bolls were found in only one treatment in 2003. During the same year, fallen oviposition-punctured squares were more numerous in the late-planted treatment than in the earlier treatments. Treatment effects were not found on numbers of oviposition-punctured bolls, but fallen oviposition-punctured squares were more common than bolls in the late-planted treatment compared with earlier treatments each year. Dead weevil eggs, larvae, and pupae inside fallen fruit were few and planting date treatment effects were not detected. Living third instars and pupae were more abundant in fallen squares of the late-planted treatment than in the earlier treatments and bolls of all three treatments. This study shows that fallen squares in late-planted cotton contribute more to adult boll weevil populations than bolls, or squares of earlier plantings.

  12. Contrast enhanced computed tomography and reconstruction of hepatic vascular system for transjugular intrahepatic portal systemic shunt puncture path planning.

    PubMed

    Qin, Jian-Ping; Tang, Shan-Hong; Jiang, Ming-De; He, Qian-Wen; Chen, Hong-Bin; Yao, Xin; Zeng, Wei-Zheng; Gu, Ming

    2015-08-28

    To describe a method for the transjugular intrahepatic portal systemic shunt (TIPS) placement performed with the aid of contrast-enhanced computed tomography (CECT) and three-dimensional reconstructed vascular images (3D RVIs), and to assess its safety and effectiveness. Four hundred and ninety patients were treated with TIPS between January 2005 and December 2012. All patients underwent liver CECT and reconstruction of 3D RVIs of the right hepatic vein to portal vein (PV) prior to the operation. The 3D RVIs were carefully reviewed to plan the puncture path from the start to target points for needle pass through the PV in the TIPS procedure. The improved TIPS procedure was successful in 483 (98.6%) of the 490 patients. The number of punctures attempted was one in 294 (60%) patients, 2 to 3 in 147 (30%) patients, 4 to 6 in 25 (5.1%) patients and more than 6 in 17 (3.5%) patients. Seven patients failed. Of the 490 patients, 12 had punctures into the artery, 15 into the bile duct, eight into the gallbladder, and 18 through the liver capsule. Analysis of the portograms from the 483 successful cases indicated that the puncture points were all located distally to the PV bifurcation on anteroposterior images, while the points were located proximally to the bifurcation in the three cases with intraabdominal bleeding. The complications included three cases of bleeding, of whom one died and two needed surgery. Use of CECT and 3D RVIs to plan the puncture path for TIPS procedure is safe, simple and effective for clinical use.

  13. Real-time ultrasound-guided PCNL using a novel SonixGPS needle tracking system.

    PubMed

    Li, Xiang; Long, Qingzhi; Chen, Xingfa; He, Dalin; Dalin, He; He, Hui

    2014-08-01

    SonixGPS is a successful ultrasound guidance position system. It helps to improve accuracy in performing complex puncture operations. This study firstly used SonixGPS to perform kidney calyx access in PCNL to investigate its effectiveness and safety. This was a prospectively randomized controlled study performed from September 2011 to October 2012. A total of 97 patients were prospectively randomized into two groups using random number generated from SAS software. 47 Patients were enrolled in conventional ultrasound-guided (US-guided) group and 50 patients were classified into SonixGPS-guided group. Nine patients were lost during follow-up. Hence, a total of 88 patients were qualified and analyzed. Preoperative examinations included urine analysis, urine culture, kidney function, coagulation profile and routine analysis of blood. Ultrasonography was used to evaluate the degree of hydronephrosis. The intraoperative findings, including blood loss, operating time, time to successful puncture, the number of attempts for successful puncture and hospital stay were recorded. The stone clearance rate and complications were analyzed. The present study showed no significant difference between the two groups in terms of demographic data, preoperative markers, stone clearance rate and the stone composition. However, the time to successful puncture, the number of trials for successful puncture, operating time and hospital length of stay were significantly decreased in the SonixGPS-guided group. Furthermore, the hemoglobin decrease was also obviously lower in the SonixGPS group than that in conventional US-guided group. SonixGPS needle tacking system guided PCNL is safe and effective in treating upper urinary tract stones. This novel technology makes puncturing more accuracy and can significantly decrease the incidence of relative hemorrhage and accelerate recovery.

  14. Chlorine tank car puncture resistance evaluation

    DOT National Transportation Integrated Search

    1992-07-01

    Experimental studies have been conducted to evaluate the relative puncture resistance of DOT 105A500W (chlorine) tank cars and DOT 112J340W (propane) tank cars equipped with 1/2-inch steel head shields. These studies included a series of full- and 1/...

  15. Puncture Self-Healing Polymers for Aerospace Applications

    NASA Technical Reports Server (NTRS)

    Gordon, Keith L.; Penner, Ronald K.; Bogert, Phil B.; Yost, W. T.; Siochi, Emilie J.

    2011-01-01

    Space exploration launch costs on the order of $10K per pound provide ample incentive to seek innovative, cost-effective ways to reduce structural mass without sacrificing safety and reliability. Damage-tolerant structural systems can provide a route to avoiding weight penalty while enhancing vehicle safety and reliability. Self-healing polymers capable of spontaneous puncture repair show great promise to mitigate potentially catastrophic damage from events such as micrometeoroid penetration. Effective self-repair requires these materials to heal instantaneously following projectile penetration while retaining structural integrity. Poly(ethylene-co-methacrylic acid) (EMMA), also known as Surlyn is an ionomer-based copolymer that undergoes puncture reversal (self-healing) following high impact puncture at high velocities. However EMMA is not a structural engineering polymer, and will not meet the demands of aerospace applications requiring self-healing engineering materials. Current efforts to identify candidate self-healing polymer materials for structural engineering systems are reported. Rheology, high speed thermography, and high speed video for self-healing semi-crystalline and amorphous polymers will be reported.

  16. [Ethyl chloride aerosol spray for local anesthesia before arterial puncture: randomized placebo-controlled trial].

    PubMed

    Ballesteros-Peña, Sendoa; Fernández-Aedo, Irrintzi; Vallejo-De la Hoz, Gorka

    2017-06-01

    To compare the efficacy of an ethyl chloride aerosol spray to a placebo spray applied in the emergency department to the skin to reduce pain from arterial puncture for blood gas analysis. Single-blind, randomized placebo-controlled trial in an emergency department of Hospital de Basurto in Bilbao, Spain. We included 126 patients for whom arterial blood gas analysis had been ordered. They were randomly assigned to receive application of the experimental ethyl chloride spray (n=66) or a placebo aerosol spray of a solution of alcohol in water (n=60). The assigned spray was applied just before arterial puncture. The main outcome variable was pain intensity reported on an 11-point numeric rating scale. The median (interquartile range) pain level was 2 (1-5) in the experimental arm and 2 (1-4.5) in the placebo arm (P=.72). Topical application of an ethyl chloride spray did not reduce pain caused by arterial puncture.

  17. Postdural puncture headache is not an age-related symptom in children: a prospective, open-randomized, parallel group study comparing a22-gauge Quincke with a 22-gauge Whitacre needle.

    PubMed

    Kokki, H; Salonvaara, M; Herrgård, E; Onen, P

    1999-01-01

    Many reports have shown a low incidence of postdural puncture headache (PDPH) and other complaints in young children. The objective of this open-randomized, prospective, parallel group study was to compare the use of a cutting point spinal needle (22-G Quincke) with a pencil point spinal needle (22-G Whitacre) in children. We studied the puncture characteristics, success rate and incidence of postpuncture complaints in 57 children, aged 8 months to 15 years, following 98 lumbar punctures (LP). The patient/parents completed a diary at 3 and 7 days after LP. The response rate was 97%. The incidence of PDPH was similar, 15% in the Quincke group and 9% in the Whitacre group (P=0.42). The risk of developing a PDPH was not dependent on the age (r < 0.00, P=0.67). Eight of the 11 PDPHs developed in children younger than 10 years, the youngest being 23-months-old.

  18. Ghrelin inhibits proinflammatory responses and prevents cognitive impairment in septic rats.

    PubMed

    Wei, Hua; Cao, Xiaohua; Zeng, Qingwen; Zhang, Fujun; Xue, Qingsheng; Luo, Yan; Lee, Jae-Woo; Yu, Buwei; Feng, Xiaomei

    2015-05-01

    A novel stomach-derived peptide, ghrelin, is down-regulated in sepsis and its IV administration decreases proinflammatory cytokines and mitigates organ injury. In this study, we wanted to investigate the effects of ghrelin on proinflammatory responses and cognitive impairment in septic rats. Prospective, randomized, controlled experiment. Animal basic science laboratory. Sprague-Dawley rats, weighing 250-300 g. Sepsis was induced by cecal ligation and puncture. Animals were randomly divided into four groups: sham, sham + ghrelin, cecal ligation and puncture, and cecal ligation and puncture + ghrelin. Saline was given subcutaneously (30 mL/kg) at 4 and 16 hours after surgery for all rats. Septic rats were treated with ceftriaxone (30 mg/kg) and clindamycin (25 mg/kg) subcutaneously at 4 and 16 hours after surgery. Ghrelin (80 μg/kg) was administrated intraperitoneally 4 and 16 hours after surgery in sham + ghrelin group and cecal ligation and puncture + ghrelin group. The levels of proinflammatory cytokines in hippocampus were measured by enzyme-linked immunosorbent assay, and cleaved caspase-3 was detected by Western blot 24 hours after surgery. Neuronal apoptosis was determined by terminal deoxynucleotidyl transferase dUTP nick-end labeling staining 48 hours after surgery. Additional animals were monitored to record survival and body weight changes for 10 days after surgery. Survival animals underwent behavioral tasks 10 days after surgery: open-field, novel object recognition, and continuous multiple-trial step-down inhibitory avoidance task. Ghrelin significantly decreased the levels of proinflammatory cytokines and inhibited the activation of caspase-3 in the hippocampus after cecal ligation and puncture. The density of terminal deoxynucleotidyl transferase dUTP nick-end labeling-positive apoptotic neurons was significantly lowered by ghrelin. In addition, ghrelin improved the survival rates after cecal ligation and puncture. There were no differences in the distance and move time between groups in open-field task. However, the survivors after cecal ligation and puncture were unable to recognize the novel object and required more training trials to reach the acquisition criterion. All these long-term impairments were prevented by ghrelin. Ghrelin inhibited proinflammatory responses, improved the survival rate, and prevented cognitive impairment in septic rats.

  19. Successful use of nitrous oxide during lumbar punctures: A call for nitrous oxide in pediatric oncology clinics.

    PubMed

    Livingston, Mylynda; Lawell, Miranda; McAllister, Nancy

    2017-11-01

    Numerous reports describe the successful use of nitrous oxide for analgesia in children undergoing painful procedures. Although shown to be safe, effective, and economical, nitrous oxide use is not yet common in pediatric oncology clinics and few reports detail its effectiveness for children undergoing repeated lumbar punctures. We developed a nitrous oxide clinic, and undertook a review of pediatric oncology lumbar puncture records for those patients receiving nitrous oxide in 2011. No major complications were noted. Minor complications were noted in 2% of the procedures. We offer guidelines for establishing such a clinic. © 2017 Wiley Periodicals, Inc.

  20. A preliminary study on puncture resistances of top and bottom layers of multi-layered needlepunched nonwoven geotextiles

    NASA Astrophysics Data System (ADS)

    Alan, G.; Tercan, M.

    2017-10-01

    Needlepunched nonwoven textiles are commonly used as geotextiles for various applications. Considering both environmental and economical benefits, utilization of recycled fibres in nonwoven geotextiles has become an attractive issue. Within this scope, the aim of this study is to evaluate the puncture resistance performances of top and bottom layers of multi-layered needle punched nonwovens made of recycled fibres to be used as membrane protective geotextiles by comparing them with those of made from polypropylene and polyester fibres. Puncture resistance results indicated that nonwovens made of recycled fibres demonstrated good performances at this preliminary stage.

  1. Λ scattering equations

    NASA Astrophysics Data System (ADS)

    Gomez, Humberto

    2016-06-01

    The CHY representation of scattering amplitudes is based on integrals over the moduli space of a punctured sphere. We replace the punctured sphere by a double-cover version. The resulting scattering equations depend on a parameter Λ controlling the opening of a branch cut. The new representation of scattering amplitudes possesses an enhanced redundancy which can be used to fix, modulo branches, the location of four punctures while promoting Λ to a variable. Via residue theorems we show how CHY formulas break up into sums of products of smaller (off-shell) ones times a propagator. This leads to a powerful way of evaluating CHY integrals of generic rational functions, which we call the Λ algorithm.

  2. Interventional Management of Massive Hemothorax Due to Inadvertent Puncture of an Aberrant Right Subclavian Artery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jahnke, Thomas, E-mail: thomas.jahnke@gmx.net; Schaefer, Phillip Jost; Heller, Martin

    2008-07-15

    We report a case of massive hemothorax due to inadvertent puncture of an aberrant right subclavian artery during central venous access. Iatrogenic laceration at the origin of the right internal thoracic artery was successfully treated with coil embolization of the internal thoracic artery followed by stent-graft placement into the subclavian artery. Due to its elongated and abnormal course, an aberrant right subclavian artery may predispose to inadvertent puncture during vein catheterization and should be recognized as a potential threat for such procedures. Our case emphasizes that ultrasound guidance should be used routinely for central venous lines wherever possible.

  3. Low complexity Reed-Solomon-based low-density parity-check design for software defined optical transmission system based on adaptive puncturing decoding algorithm

    NASA Astrophysics Data System (ADS)

    Pan, Xiaolong; Liu, Bo; Zheng, Jianglong; Tian, Qinghua

    2016-08-01

    We propose and demonstrate a low complexity Reed-Solomon-based low-density parity-check (RS-LDPC) code with adaptive puncturing decoding algorithm for elastic optical transmission system. Partial received codes and the relevant column in parity-check matrix can be punctured to reduce the calculation complexity by adaptive parity-check matrix during decoding process. The results show that the complexity of the proposed decoding algorithm is reduced by 30% compared with the regular RS-LDPC system. The optimized code rate of the RS-LDPC code can be obtained after five times iteration.

  4. Modification of one man life raft

    NASA Technical Reports Server (NTRS)

    Soter, E. J. (Inventor)

    1974-01-01

    A one man inflatable life raft is described. The raft has an inflatable tube perimetrically bounding the occupant receiving space with a flexible floor member. A zippered opening in the floor allows entry and facilitates the use of a constant diameter tube. An airtight fabric bulkhead divides the peripheral tube longitudinally into inflatable tube sections, where if either tube section were punctured, the bulkhead would move into the punctured section to substitute for the punctured wall portion and maintain the inflatable volume of the tube. The floor member is attached to the central portion of the tube wall so that either side of the raft can be the up side.

  5. A Case of Prolonged Delayed Postdural Puncture Headache in a Patient with Multiple Sclerosis Exacerbated by Air Travel

    PubMed Central

    Porhomayon, Jahan; Zadeii, Gino; Yarahamadi, Alireza; Nader, Nader D.

    2013-01-01

    The developments of new spinal needles and needle tip designs have reduced the incidence of postdural puncture headache (PDPH). Although it is clear that reducing the loss of CSF leak from dural puncture reduces the headache, there are areas regarding the pathogenesis, treatment, and prevention of PDPH that remain controversial. Air travel by itself may impose physiological alteration in central nervous system that may be detrimental to patients with PDPH. This case report highlights a case of a young female patient who suffered from a severe incapacitating PDPH headache during high-altitude flight with a commercial jet. PMID:23401803

  6. A Proposed Maneuver to Guide Transseptal Puncture Using Real-Time Three-Dimensional Transesophageal Echocardiography: Pilot Study.

    PubMed

    Mahmoud, Hani M; Al-Ghamdi, Mohammed A; Ghabashi, Abdullah E; Anwar, Ashraf M

    2015-01-01

    Aim of Study. To assess the feasibility of a new proposed maneuver "RATLe-90" using real-time three-dimensional transesophageal echocardiography (RT-3DTEE) for anatomically oriented visualization of the interatrial septum (IAS) in guiding the transseptal puncture TSP. Methods. The study included 20 patients (mean age, 60.2 ± 6.7 years; 60% males) who underwent TSP for different indications. RT-3DTEE was used to guide TSP. The proposed maneuver RATLe-90 (Rotate-Anticlockwise-Tilt-Left-90) was applied in all cases to have the anatomically oriented en face view of the IAS from the right atrial (RA) aspect. Having this anatomically oriented view, we guided the TSP catheter towards the proper puncture site according to the planned procedure. Results. Using the RATLe-90 maneuver, the anatomically oriented en face view of the IAS from the RA was obtained in all patients. We were able to guide the puncture catheter to the proper puncture site on the IAS. The 3D images obtained were clearly understood by both echocardiographers and interventionists. The RATLe-90 maneuver acquisition time was 19.9 ± 1.6 seconds. The time-to-tent was 64.8 ± 16.3 seconds. Less TEE probe manipulations were needed while guiding the TSP. Conclusions. Application of RT3D-TEE during TSP using RATLe-90 maneuver is feasible with shorter fluoroscopy time and minimizing TEE probe manipulations.

  7. Subdural Hematoma Associated With Labor Epidural Analgesia: A Case Series.

    PubMed

    Lim, Grace; Zorn, Jamie M; Dong, Yuanxu J; DeRenzo, Joseph S; Waters, Jonathan H

    2016-01-01

    This report aimed to describe the characteristics and impact of subdural hematoma (SDH) after labor epidural analgesia. Eleven obstetric patients had SDHs associated with the use of labor epidural analgesia over 7 years at a tertiary care hospital. Ten of 11 patients had signs consistent with postdural puncture headache before the diagnosis of SDH. Five patients (45%) had a recognized unintentional dural puncture, 1 (9%) had a combined spinal-epidural with a 24-gauge needle, and 5 (45%) had no recognized dural puncture. For 10 of the 11 cases, SDH was diagnosed at a mean of 4.1 days (range, 1-7 days) after performance of labor epidural analgesia; one case was diagnosed at 25 days. Ten (91%) of 11 cases had a second hospital stay for a mean of 2.8 days (range, 2-4 days) for observation, without further requirement for neurosurgical intervention. One case (9%) had decompressive hemicraniectomy after becoming unresponsive. The observed rate of labor epidural analgesia-associated SDH was 0.026% (11 in 42,969, approximately 1:3900), and the rate of SDH was 1.1% (5 in 437, approximately 1:87) if a recognized dural puncture occurred during epidural catheter placement. Subdural hematoma after labor epidural anesthesia is rare but potentially more common than historically estimated. Cases of postdural puncture headache after labor epidural anesthesia should be monitored closely for severe neurologic signs and symptoms that could herald SDH.

  8. Secondary tracheoesophageal puncture in-office using Seldinger technique.

    PubMed

    Britt, Christopher J; Lippert, Dylan; Kammer, Rachael; Ford, Charles N; Dailey, Seth H; McCulloch, Timothy; Hartig, Gregory

    2014-05-01

    Evaluate the safety and efficacy of in-office secondary tracheoesophageal puncture (TEP) technique using transnasal esophagoscopy (TNE) and the Seldinger technique in conjunction with a cricothyroidotomy kit for placement. Case series with chart review. Academic medical center. A retrospective chart review was performed on 83 subjects who underwent in-office secondary TEP. Variables that were examined included disease site, staging, histologic diagnosis, extent of resection and reconstruction, chemoradiation, functional voice status (as assessed by speech pathologist in most recent note), and complications directly related to the procedure. Eighty-three individuals from our institution met our criteria for in-office secondary TEP from 2005 to August 2012. Of these, 97.6% (81/83) had no complications of TEP. The overall complication rate was 2.4% (2/83). Complications included bleeding from puncture site and closure of puncture site after dislodgement of prosthesis at the time of puncture. Fluent conversational speech was achieved in 69.9% of all patients (58/83), and an additional 19.3% (16/83) achieved functional/intelligible speech; of those, 3.6% (3/83) were unable to achieve fluent conversational speech due to anatomic defects from previous surgery. An in-office TEP can be safely performed using the Seldinger technique with direct visualization using TNE, despite the extent of resection or reconstruction, with functional speech outcomes comparable to other studies available in the literature.

  9. A Video Transmission System for Severely Degraded Channels

    DTIC Science & Technology

    2006-07-01

    rate compatible punctured convolutional codes (RCPC) . By separating the SPIHT bitstream...June 2000. 149 [170] J. Hagenauer, Rate - compatible punctured convolutional codes (RCPC codes ) and their applications, IEEE Transactions on...Farvardin [160] used rate compatible convolutional codes . They noticed that for some transmission rates , one of their EEP schemes, which may

  10. 40 CFR Table 4 to Subpart Xxxx of... - Operating Limits for Puncture Sealant Application Control Devices

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... performance test. 2. Carbon adsorber (regenerative) to which puncture sealant application spray booth emissions are ducted a. Maintain the total regeneration mass, volumetric flow, and carbon bed temperature at the operating range established during the performance test.b. Reestablish the carbon bed temperature...

  11. 78 FR 52407 - Airworthiness Directives; Eurocopter France Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-23

    ... the flotation gear. (A) Unfold and visually inspect the float assemblies for any cuts, tears... inflating valve and inspect the fabric panels and girts for any cuts, tears, punctures, or abrasion. If there is a cut, tear, puncture, or any abrasion, repair the float. (2) For emergency floatation gear...

  12. 49 CFR 179.16 - Tank-head puncture-resistance systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... CARS General Design Requirements § 179.16 Tank-head puncture-resistance systems. (a) Performance...; and (3) The impacted tank car is pressurized to at least 6.9 Bar (100 psig). (b) Verification by... design and test requirements of the full-head protection (shields) or full tank-head jackets must meet...

  13. Recent Advances in Thermoplastic Puncture-Healing Polymers

    NASA Technical Reports Server (NTRS)

    Bogert, Philip B.; Working, Dennis C.; Wise, Kristopher E.; Smith, Janice Y.; Topping, Crystal C.; Britton, Sean M.; Bagby, Paul R.; Siochi, Emilie J.

    2010-01-01

    The motivation for this work is to develop self-healing polymeric materials to enable damage tolerant systems, and to tailor puncture healing for use temperatures and applications. This will be a benefit in environments and conditions where access for manual repair is limited or impossible, or where damage may not be detected.

  14. Combined coding and delay-throughput analysis for fading channels of mobile satellite communications

    NASA Technical Reports Server (NTRS)

    Wang, C. C.; Yan, Tsun-Yee

    1986-01-01

    This paper presents the analysis of using the punctured convolutional code with Viterbi decoding to improve communications reliability. The punctured code rate is optimized so that the average delay is minimized. The coding gain in terms of the message delay is also defined. Since using punctured convolutional code with interleaving is still inadequate to combat the severe fading for short packets, the use of multiple copies of assignment and acknowledgment packets is suggested. The performance on the average end-to-end delay of this protocol is analyzed. It is shown that a replication of three copies for both assignment packets and acknowledgment packets is optimum for the cases considered.

  15. Rapidly developing gas gangrene due to a simple puncture wound.

    PubMed

    Oncel, Selim; Arsoy, Emin Sami

    2010-06-01

    Gas gangrene, an infection caused by Clostridium perfringens, is a potentially fatal and physically disabling disease due to its sometimes incredibly rapid progression. An adolescent boy was referred to our university hospital with a history of nail puncture in the hand that occurred a few hours previously. The physical examination revealed a swollen and tender arm with crepitations up to the shoulder. Gas was coming out from the puncture wound with digital pressure on the forearm. The plain radiograph of the arm was typical of gas gangrene with the presence of gas under the skin and between muscular fibrils.Having received 1 dose of meropenem, the boy had surgery, in which his entire upper extremity had to be disarticulated from the shoulder. The maintenance antimicrobial therapy with intravenously administered penicillin G and clindamycin was continued for a duration of 10 days, at the end of which, the patient was discharged.The rapidly progressive character and the dramatic ending of this case made us wonder whether antimicrobial prophylaxis would play any role in the preventive management of puncture wounds.

  16. A 5-Year Audit of Accidental Dural Punctures, Postdural Puncture Headaches, and Failed Regional Anesthetics at a Tertiary-Care Medical Center

    PubMed Central

    Singh, Sukhdip; Chaudry, Shagufta Y.; Phelps, Amy L.; Vallejo, Manuel C

    2009-01-01

    Obstetric anesthesia-related complications occur as a result of labor epidural or spinal placement. The purpose of this continuous quality-improvement audit was to review the occurrence of accidental dural punctures (ADPs), postdural puncture headaches (PDPHs), and failed regional anesthetics at an academic tertiary-care medical center over a 5-year period. Obstetric anesthesia complications contained in three databases consisting of ADPs, PDPHs, and failed regional anesthetics were matched to a perinatal database, with no complications serving as controls. Of the 40,894 consecutive parturients, there were 765 documented complications. Complication rates were 0.73% (95% CI: 0.65–0.82) for ADP, 0.49% (95% CI: 0.43–0.56) for PDPH, and 0.65% (95% CI: 0.57–0.73) for failed regional anesthetic. When compared to the no complication group, factors associated with obstetric anesthesia complications included increased weight and BMI (p < 0.01), epidural block (p < 0.01), and vaginal delivery (p< 0.01). PMID:19649510

  17. A new posterior iliac puncture/aspiration needle.

    PubMed

    Islam, Anwarul

    2016-03-25

    The needles that are currently used for obtaining bone marrow aspirate samples from the posterior ilium are typically those of 1930s vintage (eg, Klima, Salah or similar needles), which were specifically designed for sternal aspiration. These needles are not designed to obtain bone marrow aspirate samples from the posterior ilium and as a result they are unsatisfactory particularly if the patient is large or obese. A new posterior iliac puncture/aspiration needle has therefore been designed, which is particularly suited for bone marrow aspiration from the posterior ilium. The needle was tested on five cadavers and on five patients. The design and construction of the needle was found to be satisfactory and a marked improvement over the conventional sternal puncture needles particularly when large or obese patients were concerned. The new posterior iliac bone marrow aspiration needle has advantages that overcome the limitations of using a conventional sternal puncture needle to obtain marrow aspirates from the posterior ilium. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  18. Simple Systems for Detecting Spacecraft Meteoroid Punctures

    NASA Technical Reports Server (NTRS)

    Hall, Stephen B.

    2004-01-01

    A report describes proposed systems to be installed in spacecraft to detect punctures by impinging meteoroids or debris. Relative to other systems that have been used for this purpose, the proposed systems would be simpler and more adaptable, and would demand less of astronauts attention and of spacecraft power and computing resources. The proposed systems would include a thin, hollow, hermetically sealed panel containing an inert fluid at a pressure above the spacecraft cabin pressure. A transducer would monitor the pressure in the panel. It is assumed that an impinging object that punctures the cabin at the location of the panel would also puncture the panel. Because the volume of the panel would be much smaller than that of the cabin, the panel would lose its elevated pressure much faster than the cabin would lose its lower pressure. The transducer would convert the rapid pressure drop to an electrical signal that could trigger an alarm. Hence, the system would provide an immediate indication of the approximate location of a small impact leak, possibly in time to take corrective action before a large loss of cabin pressure could occur.

  19. Mathematical Analysis of Space Radiator Segmenting for Increased Reliability and Reduced Mass

    NASA Technical Reports Server (NTRS)

    Juhasz, Albert J.

    2001-01-01

    Spacecraft for long duration deep space missions will need to be designed to survive micrometeoroid bombardment of their surfaces some of which may actually be punctured. To avoid loss of the entire mission the damage due to such punctures must be limited to small, localized areas. This is especially true for power system radiators, which necessarily feature large surface areas to reject heat at relatively low temperature to the space environment by thermal radiation. It may be intuitively obvious that if a space radiator is composed of a large number of independently operating segments, such as heat pipes, a random micrometeoroid puncture will result only in the loss of the punctured segment, and not the entire radiator. Due to the redundancy achieved by independently operating segments, the wall thickness and consequently the weight of such segments can be drastically reduced. Probability theory is used to estimate the magnitude of such weight reductions as the number of segments is increased. An analysis of relevant parameter values required for minimum mass segmented radiators is also included.

  20. A model of motor performance during surface penetration: from physics to voluntary control.

    PubMed

    Klatzky, Roberta L; Gershon, Pnina; Shivaprabhu, Vikas; Lee, Randy; Wu, Bing; Stetten, George; Swendsen, Robert H

    2013-10-01

    The act of puncturing a surface with a hand-held tool is a ubiquitous but complex motor behavior that requires precise force control to avoid potentially severe consequences. We present a detailed model of puncture over a time course of approximately 1,000 ms, which is fit to kinematic data from individual punctures, obtained via a simulation with high-fidelity force feedback. The model describes puncture as proceeding from purely physically determined interactions between the surface and tool, through decline of force due to biomechanical viscosity, to cortically mediated voluntary control. When fit to the data, it yields parameters for the inertial mass of the tool/person coupling, time characteristic of force decline, onset of active braking, stopping time and distance, and late oscillatory behavior, all of which the analysis relates to physical variables manipulated in the simulation. While the present data characterize distinct phases of motor performance in a group of healthy young adults, the approach could potentially be extended to quantify the performance of individuals from other populations, e.g., with sensory-motor impairments. Applications to surgical force control devices are also considered.

  1. [Postspinal headache. A comparison of the 24G Sprotte syringe and a 29G Quincke needle].

    PubMed

    Lim, M; Cross, G D; Sold, M

    1992-09-01

    A randomised study was performed to compare the frequency of postdural puncture headache in 56 patients who underwent spinal anaesthesia for extra-corporeal shockwave lithotripsy using either a Sprotte 24 G (n = 28) or Vygon 29 G or Quincke type needle (n = 28). Frequency of headache was recorded in a similar group of 28 patients who received general anaesthesia. Dural puncture was easier with the Sprotte 24 G cannula than with the less stable Quincke needle, as documented by a significantly shortened time for insertion of the cannula (4.6 +/- 2.6 vs 8.6 +/- 6.3 min, P less than 0.005). The total frequency of post-operative headache was 57% in the Vygon 29 G group and 25% in the Sprotte 24 G group; 21% of patients in the general anaesthesia group complained of headache. Frequency of postdural puncture headache, classified as being posture-related, was 25% in the 29 G Vygon group, compared with 11% in the 24 G Sprotte group (P = 0.148). When only moderate and severe postdural puncture headache was considered, there was a significant difference (25% vs. 4%; P = 0.026) in favour of the Sprotte cannula. Thus, the 24 G Sprotte needle was at least as effective as the 29 G Vygon needle, and there is a suggestion that the former is more effective in minimising the incidence of moderate or severe postdural puncture headache.

  2. CT-Guided Superior Vena Cava Puncture: A Solution to Re-Establishing Access in Haemodialysis-Related Central Venous Occlusion Refractory to Conventional Endovascular Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khalifa, Mohamed, E-mail: mkhalifa@nhs.net; Patel, Neeral R., E-mail: neeral.patel06@gmail.com; Moser, Steven, E-mail: steven.moser@imperial.nhs.uk

    PurposeThe purpose of this technical note is to demonstrate the novel use of CT-guided superior vena cava (SVC) puncture and subsequent tunnelled haemodialysis (HD) line placement in end-stage renal failure (ESRF) patients with central venous obstruction refractory to conventional percutaneous venoplasty (PTV) and wire transgression, thereby allowing resumption of HD.MethodsThree successive ESRF patients underwent CT-guided SVC puncture with subsequent tract recanalisation. Ultrasound-guided puncture of the right internal jugular vein was performed, the needle advanced to the patent SVC under CT guidance, with subsequent insertion of a stabilisation guidewire. Following appropriate tract angioplasty, twin-tunnelled HD catheters were inserted and HD resumed.ResultsNomore » immediate complications were identified. There was resumption of HD in all three patients with a 100 % success rate. One patient’s HD catheter remained in use for 2 years post-procedure, and another remains functional 1 year to the present day. One patient died 2 weeks after the procedure due to pancreatitis-related abdominal sepsis unrelated to the Tesio lines.ConclusionCT-guided SVC puncture and tunnelled HD line insertion in HD-related central venous occlusion (CVO) refractory to conventional recanalisation options can be performed safely, requires no extra equipment and lies within the skill set and resources of most interventional radiology departments involved in the management of HD patients.« less

  3. Impact of Smartphone Applications on Timing of Endovascular Therapy for Ischemic Stroke: A Preliminary Study.

    PubMed

    Alotaibi, Naif M; Sarzetto, Francesca; Guha, Daipayan; Lu, Michael; Bodo, Andre; Gupta, Shaurya; Dyer, Erin; Howard, Peter; da Costa, Leodante; Swartz, Richard H; Boyle, Karl; Nathens, Avery B; Yang, Victor X D

    2017-11-01

    The metrics of imaging-to-puncture and imaging-to-reperfusion were recently found to be associated with the clinical outcomes of endovascular thrombectomy for acute ischemic stroke. However, measures for improving workflow within hospitals to achieve better timing results are largely unexplored for endovascular therapy. The aim of this study was to examine our experience with a novel smartphone application developed in house to improve our timing metrics for endovascular treatment. We developed an encrypted smartphone application connecting all stroke team members to expedite conversations and to provide synchronized real-time updates on the time window from stroke onset to imaging and to puncture. The effects of the application on the timing of endovascular therapy were evaluated with a secondary analysis of our single-center cohort. Our primary outcome was imaging-to-puncture time. We assessed the outcomes with nonparametric tests of statistical significance. Forty-five patients met our criteria for analysis among 66 consecutive patients with acute ischemic stroke who received endovascular therapy at our institution. After the implementation of the smartphone application, imaging-to-puncture time was significantly reduced (preapplication median time, 127 minutes; postapplication time, 69 minutes; P < 0.001). Puncture-to-reperfusion time was not affected by the application use (42 minutes vs. 36 minutes). The use of smartphone applications may reduce treatment times for endovascular therapy in acute ischemic stroke. Further studies are needed to confirm our findings. Copyright © 2017. Published by Elsevier Inc.

  4. Plantar and Pedal Puncture Wounds in Children: A Case Series Study From a Single Level I Trauma Center.

    PubMed

    Volk, Angela; Zebda, Mohamed; Abdelgawad, Amr A

    2017-11-01

    The purpose of this study was to describe our experience in treatment of pediatric patient presenting with pedal puncture wound to our level I trauma center and describe our results for the need for hospitalization and/or surgery for these patients. Children and adolescents 18 years and younger presenting with pedal puncture wounds from September 2009 to December of 2013 were retrospectively studied. Exclusion criteria included adult patients, wounds related to animal bites, lacerations associated with a motor vehicle collision or all-terrain vehicle accidents, gunshot wounds, degloving injuries, or injuries resulting in complex lacerations to the foot. A total of 147 children presented to emergency department (ED) with a pedal puncture wound. Average age was 9.8 years. Prophylactic antibiotic therapy was administered in 107 cases (72.8%). Fifteen patients (10%) were treated with intravenous or intramuscular antibiotics in the ED or after hospital admission, 81 patients (55%) were treated with oral medications (prescribed for them to be taken after discharge), and 35 patients (24%) received topical antibiotic treatment. Of the 147 patients included in the study, 9 patients (6%) required the need for hospitalization. Two patients were admitted for parenteral antibiotic treatment only, and 7 patients required formal surgical debridement in the operating room in addition to parenteral antibiotic therapy. The majority of pediatric patients with pedal puncture wounds were treated in the ED with only a small percentage of patients requiring admission for either parenteral antibiotic treatment or formal surgical debridement.

  5. Factors Associated With the Onset and Persistence of Post–Lumbar Puncture Headache

    PubMed Central

    Monserrate, Andrés E.; Ryman, Davis C.; Ma, Shengmei; Xiong, Chengjie; Noble, James M.; Ringman, John M.; Morris, John C.; Danek, Adrian; Müller-Sarnowski, Felix; Clifford, David B.; McDade, Eric M.; Brooks, William S.; Darby, David G.; Masters, Colin L.; Weston, Philip S. J.; Farlow, Martin R.; Graff-Radford, Neill R.; Salloway, Stephen P.; Fagan, Anne M.; Oliver, Angela; Bateman, Randall J.

    2015-01-01

    IMPORTANCE This study assesses factors associated with the most common adverse event following lumbar puncture. OBJECTIVE To identify factors associated with the risk, onset, and persistence of post–dural puncture headache (PDPH). DESIGN, SETTING, AND PARTICIPANTS We performed univariate and multivariable analyses of 338 lumbar punctures in the Dominantly Inherited Alzheimer Network observational study using linear mixed models, adjusting for participant-level and family-level random effects. MAIN OUTCOMES AND MEASURES We directly evaluated associations of 3 post–lumbar puncture outcomes (immediate postprocedural headache, PDPH at 24-hour follow-up, and PDPH receiving a therapeutic blood patch) with participant age and sex, positioning, collection method, needle size, needle insertion site, and cerebrospinal fluid (CSF) volume collected. RESULTS The incidence of adverse events included 73 immediate postprocedural headaches (21.6%), 59 PDPHs at 24-hour follow-up (17.5%), and 15 PDPHs receiving a therapeutic blood patch (4.4%). Greater volume of CSF collected was associated with increased risk of immediate postprocedural headache, largely owing to a nonlinear increase in risk on collection of volumes above 30 mL (odds ratio, 3.73 for >30 mL and 0.98 for <17 mL). In contrast, collection of higher volumes showed a protective effect in decreasing rates of PDPH at 24-hour follow-up and rates of PDPH receiving a therapeutic blood patch (odds ratio, 0.35 per 10 mL). Although differences in needle size did not reach statistical significance, no participant in the 24G needle group received a therapeutic blood patch compared to 8 of 253 for the larger 22G needles. CONCLUSIONS AND RELEVANCE Factors that acutely lower CSF pressure (eg, seated positioning or extracting very high volumes of CSF) may be associated with transient post-lumbar puncture headache, without increasing rates of persistent PDPH or therapeutic blood patch. Collection of up to 30 mL of CSF appears to be well tolerated and safe. PMID:25622095

  6. Microneedle Arrays Allow Lower Microbial Penetration Than Hypodermic Needles In Vitro

    PubMed Central

    Donnelly, Ryan F.; Singh, Thakur Raghu Raj; Tunney, Michael M.; Morrow, Desmond I. J.; McCarron, Paul A.; O’Mahony, Conor; Woolfson, A. David

    2010-01-01

    Methods In this study we determined, for the first time, the ability of microorganisms to traverse microneedle-induced holes using two different in vitro models. Results When employing Silescol® membranes, the numbers of Candida albicans, Pseudomonas aeruginosa and Staphylococcus epidermidis crossing the membranes were an order of magnitude lower when the membranes were punctured by microneedles rather than a 21G hypodermic needle. Apart from the movement of C. albicans across hypodermic needle-punctured membranes, where 40.2% of the microbial load on control membranes permeated the barrier over 24 h, the numbers of permeating microorganisms was less than 5% of the original microbial load on control membranes. Experiments employing excised porcine skin and radiolabelled microorganisms showed that the numbers of microorganisms penetrating skin beyond the stratum corneum were approximately an order of magnitude greater than the numbers crossing Silescol® membranes in the corresponding experiments. Approximately 103cfu of each microorganism adhered to hypodermic needles during insertion. The numbers of microorganisms adhering to MN arrays were an order of magnitude higher in each case. Conclusion We have shown here that microneedle puncture resulted in significantly less microbial penetration than did hypodermic needle puncture and that no microorganisms crossed the viable epidermis in microneedle—punctured skin, in contrast to needle-punctured skin. Given the antimicrobial properties of skin, it is, therefore, likely that application of microneedle arrays to skin in an appropriate manner would not cause either local or systemic infection in normal circumstances in immune-competent patients. In supporting widespread clinical use of microneedle-based delivery systems, appropriate animal studies are now needed to conclusively demonstrate this in vivo. Safety in patients will be enhanced by aseptic or sterile manufacture and by fabricating microneedles from self-disabling materials (e.g. dissolving or biodegradable polymers) to prevent inappropriate or accidental reuse. PMID:19756972

  7. Self-taught axillary vein access without venography for pacemaker implantation: prospective randomized comparison with the cephalic vein access.

    PubMed

    Squara, Fabien; Tomi, Julien; Scarlatti, Didier; Theodore, Guillaume; Moceri, Pamela; Ferrari, Emile

    2017-12-01

    Axillary vein access for pacemaker implantation is uncommon in many centres because of the lack of training in this technique. We assessed whether the introduction of the axillary vein technique was safe and efficient as compared with cephalic vein access, in a centre where no operators had any previous experience in axillary vein puncture. Patients undergoing pacemaker implantation were randomized to axillary or cephalic vein access. All three operators had no experience nor training in axillary vein puncture, and self-learned the technique by reading a published review. Axillary vein puncture was fluoroscopy-guided without contrast venography. Cephalic access was performed by dissection of delto-pectoral groove. Venous access success, venous access duration (from skin incision to guidewire or lead in superior vena cava), procedure duration, X-ray exposure, and peri-procedural (1 month) complications were recorded. results We randomized 74 consecutive patients to axillary (n = 37) or cephalic vein access (n = 37). Axillary vein was successfully accessed in 30/37 (81.1%) patients vs. 28/37 (75.7%) of cephalic veins (P = 0.57). Venous access time was shorter in axillary group than in cephalic group [5.7 (4.4-8.3) vs. 12.2 (10.5-14.8) min, P < 0.001], as well as procedure duration [34.8 (30.6-38.4) vs. 42.0 (39.1-46.6) min, P = 0.043]. X-ray exposure and peri-procedural overall complications were comparable in both groups. Axillary puncture was safe and faster than cephalic access even for the five first procedures performed by each operator. Self-taught axillary vein puncture for pacemaker implantation seems immediately safe and faster than cephalic vein access, when performed by electrophysiologists trained to pacemaker implantation but not to axillary vein puncture. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For Permissions, please email: journals.permissions@oup.com.

  8. [Comparison of efficacy and complications of 27G and 29G Sprottte needles for subarachnoid anesthesia].

    PubMed

    Morros-Viñoles, C; Pérez-Cuenca, M D; Cedó-Lluís, E; Colls, C; Bueno, J; Cedó-Vallobá, F

    2002-11-01

    Post-dural puncture headache and lumbar backache are related to needle gauge and type of point used. We aimed to determine whether the incidence of post-dural puncture headache and lumbar backache could be reduced by using fine gauge pencil-point Sprotte 27G and 29G needles. We also studied increases in technical difficulty with these needles and whether or not reducing needle gauge affected anesthetic quality. Three hundred eighty-nine patients undergoing orthopedic or lower abdominal surgery were randomly assigned to two groups for dural puncture using two Sprotte needles: 27G or 29G. We recorded time to perform puncture, number of re-insertations of the needle, number of times the technique was abandoned and anesthetic efficacy. On the second and seventh days, the patients were interviewed by telephone to check for the presence and severity of post-dural puncture headache or lumbar backache. The technical difficulty was greater with the Sprotte 29G needle, as shown by significant differences in time taken to perform the puncture and the number of re-insertions (p < 0.05). Anesthetic quality was the same in both groups and the percentage of failures was 0.5% for both. Five percent of patients in the 27G group and 3% in the 29G group experienced slight or moderate headache on the second day. No cases of severe cephalea were reported. Lumbar backache was reported on the second day by 26% and 18.5% of the patients in the 27G and 29G groups, respectively, but the rates decreased to 4.5% and 0.5% on the seventh day. The differences were significant, favoring the 29G needle. The use of 29G pencil-point needles can be recommended to reduce the incidence of headache and lumbar backache in the postoperative period, in spite of the greater technical difficulty involved, given that quality of anesthesia is maintained.

  9. Three-Dimensional Ultrasound-Guided Real-Time Midline Epidural Needle Placement with Epiguide: A Prospective Feasibility Study.

    PubMed

    Beigi, Parmida; Malenfant, Paul; Rasoulian, Abtin; Rohling, Robert; Dube, Alison; Gunka, Vit

    2017-01-01

    Current 2-D ultrasound technology is unable to perform a midline neuraxial needle insertion under real-time ultrasound guidance using a standard needle and without an assistant. The aim of the work described here was to determine the feasibility of a new technology providing such capability, starting with a study evaluating the selected puncture site. A novel 3-D ultrasound imaging technique was designed using thick-slice rendering in conjunction with a custom needle guide (3DUS + Epiguide). A clinical feasibility study evaluated the ability of 3DUS + Epiguide to identify the epidural needle puncture site for a midline insertion in the lumbar spine. We hypothesized that (i) the puncture site identified by 3DUS + Epiguide was within a 5-mm radius from the site chosen by standard palpation, and (ii) the difference between the two puncture sites was not correlated to the patient characteristics age, weight, height, body mass index and gestational age. The mean (±standard deviation) distances between puncture sites determined by 3DUS + Epiguide and palpation were 3.1 (±1.7) mm and 2.8 (±1.3) mm, for the L2-3 and L3-4 interspaces of 20 patients, respectively. Distances were comparable to intra-observer variability, indicating the potential for a thick-slice rendering of 3-D ultrasound along the Epiguide trajectory to select the puncture site of a midline neuraxial needle insertion. The long-term potential benefits of this system include increased efficiency and use of anesthesia, and a reduction in the frequency and severity of the complications from incorrect needle insertions. Epidural success in the most difficult cases (e.g., the obese) will be the focus of future work. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  10. Injection of AAV2-BMP2 and AAV2-TIMP1 into the nucleus pulposus slows the course of intervertebral disc degeneration in an in vivo rabbit model.

    PubMed

    Leckie, Steven K; Bechara, Bernard P; Hartman, Robert A; Sowa, Gwendolyn A; Woods, Barrett I; Coelho, Joao P; Witt, William T; Dong, Qing D; Bowman, Brent W; Bell, Kevin M; Vo, Nam V; Wang, Bing; Kang, James D

    2012-01-01

    Intervertebral disc degeneration (IDD) is a common cause of back pain. Patients who fail conservative management may face the morbidity of surgery. Alternative treatment modalities could have a significant impact on disease progression and patients' quality of life. To determine if the injection of a virus vector carrying a therapeutic gene directly into the nucleus pulposus improves the course of IDD. Prospective randomized controlled animal study. Thirty-four skeletally mature New Zealand white rabbits were used. In the treatment group, L2-L3, L3-L4, and L4-L5 discs were punctured in accordance with a previously validated rabbit annulotomy model for IDD and then subsequently treated with adeno-associated virus serotype 2 (AAV2) vector carrying genes for either bone morphogenetic protein 2 (BMP2) or tissue inhibitor of metalloproteinase 1 (TIMP1). A nonoperative control group, nonpunctured sham surgical group, and punctured control group were also evaluated. Serial magnetic resonance imaging (MRI) studies at 0, 6, and 12 weeks were obtained, and a validated MRI analysis program was used to quantify degeneration. The rabbits were sacrificed at 12 weeks, and L4-L5 discs were analyzed histologically. Viscoelastic properties of the L3-L4 discs were analyzed using uniaxial load-normalized displacement testing. Creep curves were mathematically modeled according to a previously validated two-phase exponential model. Serum samples obtained at 0, 6, and 12 weeks were assayed for biochemical evidence of degeneration. The punctured group demonstrated MRI and histologic evidence of degeneration as expected. The treatment groups demonstrated less MRI and histologic evidence of degeneration than the punctured group. The serum biochemical marker C-telopeptide of collagen type II increased rapidly in the punctured group, but the treated groups returned to control values by 12 weeks. The treatment groups demonstrated several viscoelastic properties that were distinct from control and punctured values. Treatment of punctured rabbit intervertebral discs with AAV2-BMP2 or AAV2-TIMP1 helps delay degenerative changes, as seen on MRI, histologic sampling, serum biochemical analysis, and biomechanical testing. Although data from animal models should be extrapolated to the human condition with caution, this study supports the potential use of gene therapy for the treatment of IDD. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Atraumatic versus traumatic lumbar puncture needles: a systematic review and meta-analysis protocol

    PubMed Central

    Nath, Siddharth; Badhiwala, Jetan H; Alhazzani, Waleed; Nassiri, Farshad; Belley-Cote, Emilie; Koziarz, Alex; Shoamanesh, Ashkan; Banfield, Laura; Oczkowski, Wieslaw; Sharma, Mike; Sahlas, Demetrios; Reddy, Kesava; Farrokhyar, Forough; Singh, Sheila; Sharma, Sunjay; Zytaruk, Nicole; Selim, Magdy; Almenawer, Saleh A

    2017-01-01

    Introduction Lumbar puncture is one of the oldest and most commonly performed procedures in medicine, used to diagnose and treat disease. Headache following lumbar puncture remains a frequent complication, causing significant patient discomfort and often requiring narcotic analgesia or invasive therapy. Needle tip design has been proposed to affect the incidence of headache postlumbar puncture, with pencil-point ‘atraumatic’ needles thought to reduce its incidence in comparison to bevelled ‘traumatic’ needles. Despite this, the use of atraumatic needles and knowledge of their existence remains significantly limited among clinicians. This study will systematically review the evidence on atraumatic lumbar puncture needles and compare them with traumatic needles across a variety of clinical outcomes. Methods and analyses We will include published randomised controlled trials (RCTs), observational studies and abstracts, with no publication type or language restrictions. Search strategies will be designed to peruse the MEDLINE, EMBASE, Web of Science, ClinicalTrials.gov, CINAHL, WHO Clinical Trials Database and Cochrane Library databases. We will also implement strategies to search the grey literature. 3 reviewers will thoroughly and independently examine the search results, complete data abstraction and conduct quality assessment. Included RCTs will be assessed using the Cochrane risk of bias assessment tool and eligible observational studies will be examined using the Newcastle-Ottawa Scale. We will examine the outcomes of: headache and its type, intensity, duration and treatment; backache; success rate; hearing disturbance and nerve root irritation. The primary outcome will be the incidence of postdural puncture headache. We will calculate pooled estimates, relative risks for dichotomous outcomes and weighted mean differences for continuous outcomes, with corresponding 95% CIs. Statistical heterogeneity will be measured using Cochran's Q test and quantified using the I2 statistic. We will also conduct prespecified subgroup and sensitivity analyses to examine if covariates exist and to explore potential heterogeneity. Ethics and dissemination Research ethics board approval is not required for this study as it draws from published data and raises no concerns related to patient privacy. This review will provide a comprehensive assessment of the evidence on atraumatic needles for lumbar puncture and is directed to a wide audience. Results from the review will be disseminated extensively through conferences and submitted to a peer-reviewed journal for publication. Trial registration number CRD42016047546. PMID:28363928

  12. Is fracture a bigger problem for smaller animals? Force and fracture scaling for a simple model of cutting, puncture and crushing

    PubMed Central

    Choi, Seunghee; Coon, Joshua J.; Goggans, Matthew Scott; Kreisman, Thomas F.; Silver, Daniel M.; Nesson, Michael H.

    2016-01-01

    Many of the materials that are challenging for large animals to cut or puncture are also cut and punctured by much smaller organisms that are limited to much smaller forces. Small organisms can overcome their force limitations by using sharper tools, but one drawback may be an increased susceptibility to fracture. We use simple contact mechanics models to estimate how much smaller the diameter of the tips or edges of tools such as teeth, claws and cutting blades must be in smaller organisms in order for them to puncture or cut the same materials as larger organisms. In order to produce the same maximum stress when maximum force scales as the square of body length, the diameter of the tool region that is in contact with the target material must scale isometrically for punch-like tools (e.g. scorpion stings) on thick targets, and for crushing tools (e.g. molars). For punch-like tools on thin targets, and for cutting blades on thick targets, the tip or edge diameters must be even smaller than expected from isometry in smaller animals. The diameters of a small sample of unworn punch-like tools from a large range of animal sizes are consistent with the model, scaling isometrically or more steeply (positively allometric). In addition, we find that the force required to puncture a thin target using real biological tools scales linearly with tip diameter, as predicted by the model. We argue that, for smaller tools, the minimum energy to fracture the tool will be a greater fraction of the minimum energy required to puncture the target, making fracture more likely. Finally, energy stored in tool bending, relative to the energy to fracture the tool, increases rapidly with the aspect ratio (length/width), and we expect that smaller organisms often have to employ higher aspect ratio tools in order to puncture or cut to the required depth with available force. The extra stored energy in higher aspect ratio tools is likely to increase the probability of fracture. We discuss some of the implications of the suggested scaling rules and possible adaptations to compensate for fracture sensitivity in smaller organisms. PMID:27274804

  13. [Electron microscopy of the lesions produced in the human dura mater by Quincke beveled and Whitacre needles].

    PubMed

    Reina, M A; López-García, A; de Andrés-Ibáñez, J A; Dittmann, M; Cascales, M R; del Caño, M C; Daneri, J; Zambrano, O

    1997-02-01

    Comparisons of Quincke needles and non traumatic "pencil point" needles in recent years have reported lower rates of post dural puncture headache using the later type. Our new understanding of the morphology of the human dura mater motivated us to study dural lesions caused by the Whitacre 25 G and Quincke 26 G needles, using scanning electron microscopy with the aim of determining whether there is an anatomic basis for the different outcomes. The dura mater from three fresh cadavers of individuals aged 65, 70 and 72 years were punctured 40 times at an angle of 90 degrees each time. The Whitacre 25 G needle was used for 20 punctures and the Quincke 26 G needle was used for the other 20. Half the punctures were performed with the bevel in the parallel alignment and the other half with the bevel perpendicular to the spinal column. Fifteen min after causing the punctures, specimens were fixed in solutions of glutaraldehyde phosphate buffer and dehydrated in acetone. After critical point removal of the acetone, after the specimens were treated with carbon and metallized with gold. The lesions were examined externally and internally and expressed as the ratio of area of lesion to diameter of the needle that had caused them. Whitacre needle: each lesion consisted in the superimposition of multiple damaged layers that started to close individually. After 15 min the outermost layers were 90% closed and the innermost ones had closed entirely. Layers in the arachnoid surface of the dura mater had closed from 86 to 88%, while deeper layers in the thick part had closed 97 to 98%. Quincke needle: lesions were V-shaped or half-moon shaped, much like the opening formed by a can opener, on both the external and internal surfaces. Alignment of the bevel of the needle parallel to the spinal column did not lead to a different shape of puncture. After 15 min the lesions had closed 94 to 95% on the epidural surface and 95 to 96% on the arachnoid side, a difference attributable to the retraction of the arachnoid layers over the spinal column. Non traumatic beveled dural needles, termed "pencil point needles", only partially separate dural fibers, and lesions caused by these needles develop in a more complex way. The Quincke 26G needle produced a puncture that is morphologically different from that caused by the Whitacre 25G needle, although lesions produced by both types close more than 94% after 15 min. We believe the size of the lesion caused by these needles does not explain the difference in post dural puncture headache due to loss of spinal fluid.

  14. Wireless Visual Sensor Network Resource Allocation using Cross-Layer Optimization

    DTIC Science & Technology

    2009-01-01

    Rate Compatible Punctured Convolutional (RCPC) codes for channel...vol. 44, pp. 2943–2959, November 1998. [22] J. Hagenauer, “ Rate - compatible punctured convolutional codes (RCPC codes ) and their applications,” IEEE... coding rate for H.264/AVC video compression is determined. At the data link layer, the Rate - Compatible Puctured Convolutional (RCPC) channel coding

  15. Chylous Ascites: A Rare Complication of Thoracic Duct Embolization for Chylothorax

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaba, Ron C., E-mail: rgaba@uic.edu; Owens, Charles A.; Bui, James T.

    2011-02-15

    Thoracic duct embolization represents a safe and effective method to treat postsurgical chylothorax. Complications of this procedure are rare despite transabdominal puncture of lymphatic channels for thoracic duct access, and chylous ascites is unreported. Herein, we describe a case of chylous ascites formation after lymphatic puncture and attempted cannulation. Our management approach is also discussed.

  16. 75 FR 71528 - Airworthiness Directives; Dassault-Aviation Model FALCON 7X Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-24

    ... aeroplanes might, in the event of belly or gear-up landing, puncture the rear fuel tank, which could result in fuel leakage and post- landing fire. We are issuing this AD to require actions to correct the... belly or gear-up landing, puncture the rear fuel tank, which could result in fuel leakage and post...

  17. Transfundal puncture of a large ovarian cyst with hysteroscopic and ultrasonographic guidance.

    PubMed

    Zolnierczyk, Piotr; Cendrowski, Krzysztof; Sawicki, Wlodzimierz

    2015-01-01

    This paper describes the case of an 83-year-old patient with hypertension, diabetes, obesity (body mass index - 38), congestive heart failure, and history of cardiac surgery, who was referred for a diagnostic-therapeutic decompression of a large, symptomatic ovarian cyst. Due to anatomical conditions, the only safe way was a transfundal puncture under mini-hysteroscopic and ultrasound guidance. A puncture with aspiration of 300 mL of serous fluid from the cyst was performed without technical problems and complications. Cytology showed no cancer cells in the examined liquid. Relief from pain and compression discomfort was achieved in the patient. This case shows the possibility of combining ultrasound and minimally invasive diagnostic methods like hysteroscopy in selected clinical situations.

  18. Transfundal puncture of a large ovarian cyst with hysteroscopic and ultrasonographic guidance

    PubMed Central

    Zolnierczyk, Piotr; Cendrowski, Krzysztof; Sawicki, Wlodzimierz

    2015-01-01

    This paper describes the case of an 83-year-old patient with hypertension, diabetes, obesity (body mass index – 38), congestive heart failure, and history of cardiac surgery, who was referred for a diagnostic–therapeutic decompression of a large, symptomatic ovarian cyst. Due to anatomical conditions, the only safe way was a transfundal puncture under mini-hysteroscopic and ultrasound guidance. A puncture with aspiration of 300 mL of serous fluid from the cyst was performed without technical problems and complications. Cytology showed no cancer cells in the examined liquid. Relief from pain and compression discomfort was achieved in the patient. This case shows the possibility of combining ultrasound and minimally invasive diagnostic methods like hysteroscopy in selected clinical situations. PMID:25999768

  19. Ultrasound guided V3 segment vertebral artery direct percutaneous puncture for basilar artery mechanical thrombectomy in acute stroke: a technical report.

    PubMed

    Desai, Jamsheed A; Almekhlafi, Mohammed A; Hill, Michael D; Goyal, Mayank; Eesa, Muneer

    2014-04-01

    A middle aged patient presented with acute ischemic stroke due to basilar artery occlusion. The patient clinically deteriorated despite intravenous thrombolysis and was referred for mechanical thrombectomy. The right vertebral artery was occluded and could not be accessed despite attempting various shaped catheters, even when a radial artery access was used. The left vertebral artery ended in the posterior inferior cerebellar artery. Eventually, ultrasound guided V3 segment vertebral artery direct puncture was successfully done and the procedure was completed. No access related complications were encountered. Direct cervical arterial puncture can be safely used by experienced operators as a last resort in acute stroke cases with difficult access.

  20. Pleural Puncture that Excludes the Ablation Zone Decreases the Risk of Pneumothorax after Percutaneous Microwave Ablation in Porcine Lung

    PubMed Central

    Lee, Kyungmouk Steve; Takaki, Haruyuki; Yarmohammadi, Hooman; Srimathveeravalli, Govindarajan; Luchins, Kerith; Monette, Sébastien; Nair, Sreejit; Kishore, Sirish; Erinjeri, Joseph P.

    2017-01-01

    Purpose To test the hypothesis that the geometry of probe placement with respect to the pleural puncture site affects the risk of pneumothorax after microwave (MW) ablation in the lung. Materials and Methods Computed tomography–guided MW ablation of the lung was performed in 8 swine under general anesthesia and mechanical ventilation. The orientation of the 17-gauge probe was either perpendicular (90°) or parallel (< 30°) with respect to the pleural puncture site, and the ablation power was 30 W or 65 W for 5 minutes. After MW ablation, swine were euthanized, and histopathologic changes were assessed. Frequency and factors affecting pneumothorax were evaluated by multivariate analysis. Results Among 62 lung MW ablations, 13 (21%) pneumothoraces occurred. No statistically significant difference was noted in the rate of pneumothorax between the perpendicular and the parallel orientations of the probe (31% vs 14%; odds ratio [OR], 2.8; P = .11). The pneumothorax rate was equal for 65-W and 30-W ablation powers (21% and 21%; OR, 1.0; P = .94). Under multivariate analysis, 2 factors were independent positive predictors of pneumothorax: ablation zone inclusive of pleural insertion point (OR, 7.7; P = .02) and time since intubation (hours) (OR, 2.7; P = .02). Conclusions Geometries where the pleural puncture site excluded the ablation zone decreased pneumothorax in swine undergoing MW ablation in the lung. Treatment planning to ensure that the pleural puncture site excludes the subsequent ablation zone may reduce the rate of pneumothorax in patients undergoing MW ablation in the lung. PMID:25753501

  1. The role of invasive sonography in the differential diagnosis and treatment of intraabdominal fluid collections.

    PubMed

    Regöly-Mérei, J; Ihász, M; Szeberin, Z; Záborszky, A

    Sixty-nine ultrasound-guided interventions (23 punctures and 46 drainages) were performed on 51 patients with the suspicion of intraabdominal abscess or another type of fluid collection in a prospective-controlled study. Of the procedures, 58.8% were carried out following surgery, while in 41.2% the indication were not related to prior surgical intervention. Repeated procedures were done in 10 patients. In the group of punctures the procedure was therapeutic in 3 cases and diagnostic in 16 patients. The drainage was technically successful in 92.7%. The drain was displaced or blocked in 27% (n = 10), but reinterventions were necessary in only 5 cases for this reason. The total number of redrainages was 18.9%. The percutaneous (pc) drainage was insufficient in 8 patients (21.6%), all these patients were operated on. 62.2% of the patients recovered after pc drainage, 13.5% following redrainage (total 75.5%). In 8.1% of the cases after pc drainage and in 5.4% after pc redrainage open surgery became necessary. There was only one complication due to the procedure. Seven patients (14.3%) died of the disease which indicated the procedure. There were no fatal outcomes on the account of the intervention. Ultrasound-guided puncture is a suitable method to indicate or contraindicate open surgery in the case of intraabdominal fluid collection. The diagnostic puncture may be followed by sonographically guided drainage or in selected cases by therapeutic puncture, but if the pc drainage is insufficient, open surgery should be performed in time.

  2. Cancer Seeding Risk from an Epidural Blood Patch in Patients with Leukemia or Lymphoma.

    PubMed

    Demaree, Christopher J; Soliz, Jose M; Gebhardt, Rodolfo

    2017-04-01

    Lumber punctures are a common procedure in patients with cancer. However, a potential complication of a lumbar puncture is a postdural puncture headache. The risk of neoplastic seeding to the central nervous system has led to concern over performing epidural blood patches (EBPs) for the treatment of postdural puncture headaches in patients with cancer. The goal of this retrospective study was to evaluate cancer seeding in the central nervous system in patients diagnosed with leukemia or lymphoma. Institutional electronic records were queried over a 13-year period from 2000 to 2013 for patients with leukemia and/or lymphoma and who received at least one EBP. Demographic and procedural data, cancer treatments, and mortality were all examined. Patient records were reviewed for evidence of new-onset neoplastic central nervous system seeding after an epidural blood patch. A total of 80 patients were identified for review. Eighteen patients had a diagnosis of leukemia, and 62 had lymphoma. Following an EBP, none of the patients experienced new cancer or cancer seeding in the central nervous system following an epidural blood patch at a median follow-up of 3.74 years. Though the risks of EBP in the cancer patient population have been hypothesized, no previous studies have assessed the risk of seeding cancer to the central nervous system. Based on our results, an epidural blood patch bears low risk of cancer seeding when used to treat postdural puncture headache that is unresponsive to conservative treatments. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  3. REcanalisation and Balloon-Oriented Puncture for Re-Insertion of Dialysis Catheter in Nonpatent Central Veins (REBORN)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Too, Chow Wei, E-mail: toochowwei@gmail.com; Sayani, Raza; Lim, Elvin Yuan Ting

    PurposeTo describe a technique involving REcanalisation and Balloon-Oriented puncture for Re-insertion of dialysis catheter in Nonpatent central veins (REBORN) and to report long-term results.Materials and MethodsThis is a retrospective study of ten subjects in whom dialysis catheters were inserted using the REBORN technique from March 2012 to October 2014 and followed up till April 2016. Data on the duration of catheter usage, complications and reasons for removal were obtained. Seven patients had partially occluded lower internal jugular veins (IJV) recanalised in an antegrade fashion via a more cranial puncture. The balloon was then inflated at usual puncture site with anmore » 18G needle. The collapsed balloon was cannulated with a guide wire, and both balloon and guide wire were advanced together into the superior vena cava. This was followed by tunnelled catheter placement using standard techniques. Two patients had catheters placed in the subclavian vein using a similar antegrade technique, and one patient had catheter placed via the left IJV following retrograde recanalisation from a right femoral puncture.ResultsMean duration of catheter use was 278 days (range 32–503). Three catheters were removed due to matured arteriovenous accesses. Four patients had successful catheter change over the same subcutaneous track due to catheter malfunction. One catheter was removed after 7 months because of sepsis. No complications were reported.ConclusionThe REBORN technique allows for the preservation of central veins for future haemodialysis access, which can be challenging in patients requiring long-term dialysis.« less

  4. Feasibility of the Use of Transesophageal Echocardiography as a Surface Probe for Puncturing and Catheterization of the Internal Jugular Vein: A Randomized Controlled Pilot Study.

    PubMed

    Teng, Yi; Ou, Mengchan; Yu, Hai

    2018-02-01

    To compare the transesophageal echocardiography (TEE) probe as a surface probe with the vascular probe for guiding internal jugular vein (IJV) catheterization. Prospective, randomized, controlled pilot study. University hospital. One hundred cardiac surgery patients, including 50 adult and 50 pediatric patients. Patients in the TEE probe group received right IJV catheterization using the TEE probe, while the vascular probe group used the vascular probe for catheterization. The puncture time, first-attempt success rate, quality of the imaging with needle tip positioning, wire positioning, and catheter positioning were recorded. The incidence of complication or any adverse event also was observed. Adult patients: In the vascular probe group, the success rate for first attempt IJV catheterization was 24/25 (96%), while in the TEE probe group, the success rate for first attempt IJV catheterization was 25/25 (100%). There was no statistical difference in the puncture time, image quality, needle tip positioning, wire positioning, and catheter positioning between groups (p > 0.05). Pediatric patients: The success rate for first-attempt IJV catheterization was 100% in both groups, and there were no statistical differences in the puncture time, image quality, and positioning between the 2 groups (p > 0.05). No complications or adverse events were observed in either group. The TEE probe, used as a surface probe, can be used to guide IJV puncturing and catheterization in cardiac surgery patients with favorable feasibility and safety. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Effect of protein and glycerol concentration on the mechanical, optical, and water vapor barrier properties of canola protein isolate-based edible films.

    PubMed

    Chang, Chang; Nickerson, Michael T

    2015-01-01

    Biodegradable edible films prepared using proteins are both economically and environmentally important to the food packaging industry relative to traditional petroleum-derived synthetic materials. In the present study, the mechanical and water vapor barrier properties of casted canola protein isolate edible films were investigated as a function of protein (5.0% and 7.5%) and glycerol (30%, 35%, 40%, 45%, and 50%) content. Specifically, tensile strength and elongation, elastic modulus, puncture strength and deformation, opacity, and water vapor permeability were measured. Results indicated that tensile strength, puncture strength, and elastic modulus decreased, while tensile elongation and puncture deformation values increased as glycerol concentration increased for both 5.0% and 7.5% canola protein isolate films. Furthermore, tensile strength, puncture strength, and elastic modulus values were found to increase at higher protein concentrations within the canola protein isolate films, whereas puncture deformation values decreased. Tensile elongation was found to be similar for both canola protein isolate protein levels. Canola protein isolate films became more transparent with increasing of glycerol concentration and decreasing of canola protein isolate concentration. Water vapor permeability value was also found to increase with increasing glycerol and protein contents. Overall, results indicated that canola protein isolate films were less brittle, more malleable and transparent, and had greater water vapor permeability at higher glycerol levels. However, as protein level increased, canola protein isolate films were more brittle, less malleable and more opaque, and also had increased water vapor permeability. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  6. Validation of percutaneous puncture trajectory during renal access using 4D ultrasound reconstruction

    NASA Astrophysics Data System (ADS)

    Rodrigues, Pedro L.; Rodrigues, Nuno F.; Fonseca, Jaime C.; Vilaça, João. L.

    2015-03-01

    An accurate percutaneous puncture is essential for disintegration and removal of renal stones. Although this procedure has proven to be safe, some organs surrounding the renal target might be accidentally perforated. This work describes a new intraoperative framework where tracked surgical tools are superimposed within 4D ultrasound imaging for security assessment of the percutaneous puncture trajectory (PPT). A PPT is first generated from the skin puncture site towards an anatomical target, using the information retrieved by electromagnetic motion tracking sensors coupled to surgical tools. Then, 2D ultrasound images acquired with a tracked probe are used to reconstruct a 4D ultrasound around the PPT under GPU processing. Volume hole-filling was performed in different processing time intervals by a tri-linear interpolation method. At spaced time intervals, the volume of the anatomical structures was segmented to ascertain if any vital structure is in between PPT and might compromise the surgical success. To enhance the volume visualization of the reconstructed structures, different render transfer functions were used. Results: Real-time US volume reconstruction and rendering with more than 25 frames/s was only possible when rendering only three orthogonal slice views. When using the whole reconstructed volume one achieved 8-15 frames/s. 3 frames/s were reached when one introduce the segmentation and detection if some structure intersected the PPT. The proposed framework creates a virtual and intuitive platform that can be used to identify and validate a PPT to safely and accurately perform the puncture in percutaneous nephrolithotomy.

  7. Gauge Conditions for Moving Black Holes Without Excision

    NASA Technical Reports Server (NTRS)

    van Meter, James; Baker, John G.; Koppitz, Michael; Dae-IL, Choi

    2006-01-01

    Recent demonstrations of unexcised, puncture black holes traversing freely across computational grids represent a significant advance in numerical relativity. Stable an$ accurate simulations of multiple orbits, and their radiated waves, result. This capability is critically undergirded by a careful choice of gauge. Here we present analytic considerations which suggest certain gauge choices, and numerically demonstrate their efficacy in evolving a single moving puncture.

  8. System Design for FEC in Aeronautical Telemetry

    DTIC Science & Technology

    2012-03-12

    rate punctured convolutional codes for soft decision Viterbi...below follows that given in [8]. The final coding rate of exactly 2/3 is achieved by puncturing the rate -1/2 code as follows. We begin with the buffer c1...concatenated convolutional code (SCCC). The contributions of this paper are on the system-design level. One major contribution is to design a SCCC code

  9. Tinkertoys for the E 7 theory

    NASA Astrophysics Data System (ADS)

    Chacaltana, Oscar; Distler, Jacques; Trimm, Anderson; Zhu, Yinan

    2018-05-01

    We classify the class S theories of type E 7. These are four-dimensional N=2 superconformal field theories arising from the compactification of the E 7 (2, 0) theory on a punctured Riemann surface, C. The classification is given by listing all 3-punctured spheres ("fixtures"), and connecting cylinders, which can arise in a pants-decomposition of C. We find exactly 11,000 fixtures with three regular punctures, and an additional 48 with one "irregular puncture" (in the sense used in our previous works). To organize this large number of theories, we have created a web application at https://golem.ph.utexas.edu/class-S/E7/. Among these theories, we find 10 new ones with a simple exceptional global symmetry group, as well as a new rank-2 SCFT and several new rank-3 SCFTs. As an application, we study the strong-coupling limit of the E 7 gauge theory with 3 hypermultiplets in the 56. Using our results, we also verify recent conjectures that the T 2 compactification of certain 6 d (1, 0) theories can alternatively be realized in class S as fixtures in the E 7 or E 8 theories.

  10. Correlation of Descriptive Analysis and Instrumental Puncture Testing of Watermelon Cultivars.

    PubMed

    Shiu, J W; Slaughter, D C; Boyden, L E; Barrett, D M

    2016-06-01

    The textural properties of 5 seedless watermelon cultivars were assessed by descriptive analysis and the standard puncture test using a hollow probe with increased shearing properties. The use of descriptive analysis methodology was an effective means of quantifying watermelon sensory texture profiles for characterizing specific cultivars' characteristics. Of the 10 cultivars screened, 71% of the variation in the sensory attributes was measured using the 1st 2 principal components. Pairwise correlation of the hollow puncture probe and sensory parameters determined that initial slope, maximum force, and work after maximum force measurements all correlated well to the sensory attributes crisp and firm. These findings confirm that maximum force correlates well with not only firmness in watermelon, but crispness as well. The initial slope parameter also captures the sensory crispness of watermelon, but is not as practical to measure in the field as maximum force. The work after maximum force parameter is thought to reflect cellular arrangement and membrane integrity that in turn impact sensory firmness and crispness. Watermelon cultivar types were correctly predicted by puncture test measurements in heart tissue 87% of the time, although descriptive analysis was correct 54% of the time. © 2016 Institute of Food Technologists®

  11. CT fluoroscopy-assisted puncture of thoracic and abdominal masses: a randomized trial.

    PubMed

    Kirchner, Johannes; Kickuth, Ralph; Laufer, Ulf; Schilling, Esther Maria; Adams, Stephan; Liermann, Dieter

    2002-03-01

    We investigated the benefit of real-time guidance of interventional punctures by means of computed tomography fluoroscopy (CTF) compared with the conventional sequential acquisition guidance. In a prospective randomized trial, 75 patients underwent either CTF-guided (group A, n = 50) or sequential CT-guided (group B, n = 25) punctures of thoracic (n = 29) or abdominal (n = 46) masses. CTF was performed on the CT machine (Somatom Plus 4 Power, Siemens Corp., Forchheim, Germany) equipped with the C.A.R.E. Vision application (tube voltage 120 kV, tube current 50 mA, rotational time 0.75 s, slice thickness 10 mm, 8 frames/s). The average procedure time showed a statistically significant difference between the two study groups (group A: 564 s, group B 795 s, P = 0.0032). The mean total mAs was 7089 mAs for the CTF and 4856 mAs for the sequential image-guided intervention, respectively. The sensitivity was 71% specificity 100% positive predictive value 100% and negative predictive value 60% for the CTF-guided puncture, and 68, 100, 100 and 50% for sequential CT, respectively. CTF guidance realizes a time-saving but increases the radiation exposure dosage.

  12. Implantable venous ports in pediatric oncology: experience of single institution in Russia.

    PubMed

    Rykov, Maxim Yu; Polyakov, Vladimir G

    2016-07-12

    To review our experience with implantable venous port-systems (IVPs) in pediatric cancer patients. From 2010 to 2015 we were monitoring the treatment of 163 children (aged 3 months to 17 years) with oncologic diseases. These patients underwent venous port implantations. During insertion of 163 IVPs the following complications and technical difficulties were present: unintended puncture of the common carotid artery (CCA) during the puncture of the internal jugular vein (IJV) - 7 cases (4.3%); retrograde positioning of the distal end of the guidewire in the IJV - 17 cases (14.4%); placement of the distal end of the guidewire into the punctured subclavian vein (SV) - 12 cases (7.6%); difficulties driving the guidewire into the IJV after successful puncture - 15 cases (9.3%). The use of 163 IVPs was complicated by the following: venous port contamination - 4 cases (2.5%); occlusion of the IVPs by a clot - 8 cases (5%); withdrawal of the Huber needle bevel from the port chamber - 22 cases (13.6%); subcutaneous fat layer thinning above the port chamber - 3 cases (1.7%). There are many complications, but they can be reduced by proper choice of materials and methodology.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takizawa, Kenji, E-mail: khirari@marianna-u.ac.jp; Nakajima, Yasuo, E-mail: nakajima.yasuo@gmail.com; Ogawa, Yukihisa, E-mail: yukky.oct.22@gmail.com

    Purpose: The authors devised a new method of an axial puncture approach through the pulmonary apex (PA) for percutaneous catheter drainage (PCD) of loculated fluid collections extending to the PA. The purpose of this report is to introduce the new procedure. Methods: Percutaneous catheter drainage by the axial puncture approach was performed in two patients with limited supine position and loculated pleural fluid collection in the posteromedial part of thoracic cavity. Results: The procedures succeeded in two patients without difficulties while keeping them in a supine position, even if the loculated fluids exist in the posterior side of thoracic cavity.more » Conclusions: Percutaneous catheter drainage by the axial puncture approach is particularly effective in patients with limited supine positions and loculated pleural fluid collection in the posteromedial part of thoracic cavity.« less

  14. An in vitro comparison of fluid leakage after dural puncture with Atraucan, Sprotte, Whitacre, and Quincke needles.

    PubMed

    Morrison, L M; McCrae, A F; Foo, I; Scott, D B; Wildsmith, J A

    1996-01-01

    The study was designed to evaluate the influence of needle size and design on the rate of leakage following dural puncture. An in vitro model and fresh human lumbar dura were used to examine the rate of fluid leakage after puncture with Sprotte (24-gauge and 26-gauge), Atraucan (24-gauge and 26-gauge), Quincke (26-gauge and 29-gauge), and Whitacre (22-gauge and 25-gauge) needles. The study confirmed that finer-gauge needles tend to produce less leakage and that traditional Quincke pattern bevels result in greater leakage than pencil-point designs of the same diameter. The comparably low leakage rate produced by the Atraucan, a new needle with a terminal opening, suggests that this needle is worthy of further clinical evaluation.

  15. Nonclassical states of light with a smooth P function

    NASA Astrophysics Data System (ADS)

    Damanet, François; Kübler, Jonas; Martin, John; Braun, Daniel

    2018-02-01

    There is a common understanding in quantum optics that nonclassical states of light are states that do not have a positive semidefinite and sufficiently regular Glauber-Sudarshan P function. Almost all known nonclassical states have P functions that are highly irregular, which makes working with them difficult and direct experimental reconstruction impossible. Here we introduce classes of nonclassical states with regular, non-positive-definite P functions. They are constructed by "puncturing" regular smooth positive P functions with negative Dirac-δ peaks or other sufficiently narrow smooth negative functions. We determine the parameter ranges for which such punctures are possible without losing the positivity of the state, the regimes yielding antibunching of light, and the expressions of the Wigner functions for all investigated punctured states. Finally, we propose some possible experimental realizations of such states.

  16. Does Spinal Block Through Tattooed Skin Cause Histological Changes in Nervous Tissue and Meninges?: An Experimental Model in Rabbits.

    PubMed

    Ferraz, Isabela Leite; Barros, Guilherme Antônio Moreira de; Ferreira Neto, Patrícia Gomes; Solanki, Daneshivari; Marques, Mariângela Alencar; Machado, Vânia Maria de Vasconcelos; Cabral, Lucas Wynne; Lima, Rodrigo Moreira E; Vianna, Pedro Thadeu Galvão; Navarro, Lais Helena Camacho; Ganen, Eliana Marisa

    2015-01-01

    Although there is no documented evidence that tattoo pigments can cause neurological complications, the implications of performing neuraxial anesthesia through tattooed skin are unknown. In this study, we aimed to assess whether spinal puncture performed through tattooed skin of rabbits determines changes over the spinal cord and meninges. In addition, we sought to evaluate the presence of ink fragments entrapped in spinal needles. Thirty-six young male adult rabbits, each weighing between 3400 and 3900 g and having a spine length between 38.5 and 39 cm, were divided by lot into 3 groups as follows: GI, spinal puncture through tattooed skin; GII, spinal puncture through tattooed skin and saline injection; and GIII, spinal puncture through skin free of tattoo and saline injection. After intravenous anesthesia with ketamine and xylazine, the subarachnoid space was punctured at S1-S2 under ultrasound guidance with a 22-gauge 2½ Quincke needle. Animals in GII and GIII received 5 μL/cm of spinal length (0.2 mL) of saline intrathecally. In GI, the needle tip was placed into the yellow ligament, and no solution was injected into the intrathecal space; after tattooed skin puncture, 1 mL of saline was injected through the needle over a histological slide to prepare a smear that was dyed by the Giemsa method to enable tissue identification if present. All animals remained in captivity for 21 days under medical observation and were killed by decapitation. The lumbosacral spinal cord portion was removed for histological analysis using hematoxylin-eosin stain. None of the animals had impaired motor function or decreased nociception during the period of clinical observation. None of the animals from the control group (GIII) showed signs of injuries to meninges. In GII, however, 4 animals presented with signs of meningeal injury. The main histological changes observed were focal areas of perivascular lymphoplasmacyte infiltration in the pia mater and arachnoid. There was no signal of injury in neural tissue in any animal of both groups. Tissue coring containing ink pigments was noted in all GI smears from the spinal needles used to puncture the tattooed skin. On the basis of the present results, intrathecal injection of saline through a needle inserted through tattooed skin is capable of producing histological changes over the meninges of rabbits. Ink fragments were entrapped inside the spinal needles, despite the presence of a stylet.

  17. A Kinect™ camera based navigation system for percutaneous abdominal puncture

    NASA Astrophysics Data System (ADS)

    Xiao, Deqiang; Luo, Huoling; Jia, Fucang; Zhang, Yanfang; Li, Yong; Guo, Xuejun; Cai, Wei; Fang, Chihua; Fan, Yingfang; Zheng, Huimin; Hu, Qingmao

    2016-08-01

    Percutaneous abdominal puncture is a popular interventional method for the management of abdominal tumors. Image-guided puncture can help interventional radiologists improve targeting accuracy. The second generation of Kinect™ was released recently, we developed an optical navigation system to investigate its feasibility for guiding percutaneous abdominal puncture, and compare its performance on needle insertion guidance with that of the first-generation Kinect™. For physical-to-image registration in this system, two surfaces extracted from preoperative CT and intraoperative Kinect™ depth images were matched using an iterative closest point (ICP) algorithm. A 2D shape image-based correspondence searching algorithm was proposed for generating a close initial position before ICP matching. Evaluation experiments were conducted on an abdominal phantom and six beagles in vivo. For phantom study, a two-factor experiment was designed to evaluate the effect of the operator’s skill and trajectory on target positioning error (TPE). A total of 36 needle punctures were tested on a Kinect™ for Windows version 2 (Kinect™ V2). The target registration error (TRE), user error, and TPE are 4.26  ±  1.94 mm, 2.92  ±  1.67 mm, and 5.23  ±  2.29 mm, respectively. No statistically significant differences in TPE regarding operator’s skill and trajectory are observed. Additionally, a Kinect™ for Windows version 1 (Kinect™ V1) was tested with 12 insertions, and the TRE evaluated with the Kinect™ V1 is statistically significantly larger than that with the Kinect™ V2. For the animal experiment, fifteen artificial liver tumors were inserted guided by the navigation system. The TPE was evaluated as 6.40  ±  2.72 mm, and its lateral and longitudinal component were 4.30  ±  2.51 mm and 3.80  ±  3.11 mm, respectively. This study demonstrates that the navigation accuracy of the proposed system is acceptable, and that the second generation Kinect™-based navigation is superior to the first-generation Kinect™, and has potential of clinical application in percutaneous abdominal puncture.

  18. Assessment of Intervertebral Disc Degeneration Based on Quantitative MRI Analysis: an in vivo study

    PubMed Central

    Grunert, Peter; Hudson, Katherine D.; Macielak, Michael R.; Aronowitz, Eric; Borde, Brandon H.; Alimi, Marjan; Njoku, Innocent; Ballon, Douglas; Tsiouris, Apostolos John; Bonassar, Lawrence J.; Härtl, Roger

    2015-01-01

    Study design Animal experimental study Objective To evaluate a novel quantitative imaging technique for assessing disc degeneration. Summary of Background Data T2-relaxation time (T2-RT) measurements have been used to quantitatively assess disc degeneration. T2 values correlate with the water content of inter vertebral disc tissue and thereby allow for the indirect measurement of nucleus pulposus (NP) hydration. Methods We developed an algorithm to subtract out MRI voxels not representing NP tissue based on T2-RT values. Filtered NP voxels were used to measure nuclear size by their amount and nuclear hydration by their mean T2-RT. This technique was applied to 24 rat-tail intervertebral discs’ (IVDs), which had been punctured with an 18-gauge needle according to different techniques to induce varying degrees of degeneration. NP voxel count and average T2-RT were used as parameters to assess the degeneration process at 1 and 3 months post puncture. NP voxel counts were evaluated against X-ray disc height measurements and qualitative MRI studies based on the Pfirrmann grading system. Tails were collected for histology to correlate NP voxel counts to histological disc degeneration grades and to NP cross-sectional area measurements. Results NP voxel count measurements showed strong correlations to qualitative MRI analyses (R2=0.79, p<0.0001), histological degeneration grades (R2=0.902, p<0.0001) and histological NP cross-sectional area measurements (R2=0.887, p<0.0001). In contrast to NP voxel counts, the mean T2-RT for each punctured group remained constant between months 1 and 3. The mean T2-RTs for the punctured groups did not show a statistically significant difference from those of healthy IVDs (63.55ms ±5.88ms month 1 and 62.61ms ±5.02ms) at either time point. Conclusion The NP voxel count proved to be a valid parameter to quantitatively assess disc degeneration in a needle puncture model. The mean NP T2-RT does not change significantly in needle-puncture induced degenerated IVDs. IVDs can be segmented into different tissue components according to their innate T2-RT. PMID:24384655

  19. Endovascular Crossing of Chronic Total Occlusions Using an Impulse: An Explorative Design Study.

    PubMed

    Sakes, Aimée; van der Wiel, Marleen; Dodou, Dimitra; Breedveld, Paul

    2017-06-01

    In this study we investigated whether exerting an impulse on a Chronic Total Occlusion (CTO) improves the success rate of CTO crossing as compared to the currently used method of statically pushing the guidewire against the CTO. A prototype (Ø2 mm) was developed that generates translational momentum using a spring-loaded indenter and converts it to an impulse during impact. Mechanical performance was evaluated by measuring the peak force and momentum for different spring compressions and strike distances in air and blood-mimicking fluid. Puncture performance, in terms of number of punctures, number of strikes to puncture, and energy transfer from the indenter to the CTO, was assessed for six tip shapes (stamp, wedge, spherical, pointed, hollow spherical, and ringed) on three CTO models with different weight percentages of gelatin and calcium. As a control, a Ø0.4 mm rigid rod was tested. A maximum indenter momentum of 1.3 mNs (velocity of 3.4 m/s), a peak force of 19.2 N (vs. 1.5 N reported in literature and 2.7 N for the control), and CTO displacement of 1.4 mm (vs. 2.7 mm for the control) were measured. The spherical and ringed tips were most effective, with on average 2.3 strikes to puncture the most calcified CTO model. The prototype generated sufficient peak forces to puncture highly calcified CTO models, which are considered most difficult to cross during PCI. Furthermore, CTO displacement was minimized, resulting in a more effective procedure. In future, a smaller, faster, and flexible clinical prototype will be developed.

  20. Pressures of Wilderness Improvised Wound Irrigation Techniques: How Do They Compare?

    PubMed

    Luck, John B; Campagne, Danielle; Falcón Banchs, Roberto; Montoya, Jason; Spano, Susanne J

    2016-12-01

    Compare the pressures measured by improvised irrigation techniques to a commercial device and to prior reports. Devices tested included a commercial 500-mL compressible plastic bottle with splash guard, a 10-mL syringe, a 10-mL syringe with a 14-ga angiocatheter (with needle removed), a 50-mL Sawyer syringe, a plastic bag punctured with a 14-ga needle, a plastic bottle with cap punctured by a 14-ga needle, a plastic bottle with sports top, and a bladder-style hydration system. Each device was leveled on a support, manually compressed, and aimed toward a piece of glass. A high-speed camera placed behind the glass recorded the height of the stream upon impact at its highest and lowest point. Measurements were recorded 5 times for each device. Pressures in pounds per square inch (psi) were calculated. The syringe and angiocatheter pressures measured the highest pressures (16-49 psi). The 50-mL syringe (7-11 psi), 14-ga punctured water bottle (7-25 psi), and water bottle with sports top (3-7 psi) all measured at or above the commercial device (4-5 psi). Only the bladder-style hydration system (1-2 psi) and plastic bag with 14-ga needle puncture (2-3 psi) did not reach pressures generated by the commercial device. Pressures are consistent with those previously reported. All systems using compressible water bottles and all syringe-based systems provided pressures at or exceeding a commercial wound irrigation device. A 14-ga punctured plastic bag and bladder-style hydration pack failed to generate similar irrigation pressures. Copyright © 2016 Wilderness Medical Society. All rights reserved.

  1. Effect of Survivin gene therapy via lentivirus vector on the course of intervertebral disc degeneration in an in vivo rabbit model.

    PubMed

    Yue, Bin; Lin, Yazhou; Ma, Xuexiao; Zhang, Guoqing; Chen, Bohua

    2016-11-01

    The aim of the current study was to use gene therapy to attenuate or reverse the degenerative process within the intervertabral disc. The effect of survivin gene therapy via lentiviral vector transfection on the course of intervertebral disc degeneration was investigated in the current study in an in vivo rabbit model. A total of 15 skeletally mature female New Zealand White rabbits were randomly divided into three groups: Punctured blank control group (group A, n=5), punctured empty vector control group (group B, n=5) and the treatment group (group C, n=5). Computed tomography‑guided puncture was performed at the L3‑L4 and L4‑L5 discs, in accordance with a previously validated rabbit annulotomy model for intervertebral disc degeneration. After 3 weeks, a lentiviral vector (LV) carrying survivin was injected into the nucleus pulposus. The results demonstrated that through magnetic resonance imaging, histology, gene expression, protein content and apoptosis analyses, group A and B were observed to exhibit disc degeneration, which increased over time, and no significant difference was observed between the two groups (P>0.05). However, there was reduced disc degeneration in group C compared with the punctured control groups, and the difference was statistically significant (P<0.05). Overall, the results of the present study demonstrated that injection of the LV carrying survivin into punctured rabbit intervertebral discs acted to delay changes associated with the degeneration of the discs. Although data from animal models should be extrapolated to the human condition with caution, the present study suggests potential for the use of gene therapy to decelerate disc degeneration.

  2. Starclose SE® hemostasis after 6F direct antegrade superficial femoral artery access distal to the femoral head for peripheral endovascular procedures in obese patients.

    PubMed

    Spiliopoulos, Stavros; Kitrou, Panagiotis; Christeas, Nikolaos; Karnabatidis, Dimitris

    2016-01-01

    Direct superficial femoral artery (SFA) antegrade puncture is a valid alternative to common femoral artery (CFA) access for peripheral vascular interventions. Data investigating vascular closure device (VCD) hemostasis of distant SFA 6F access are limited. We aimed to investigate the safety and effectiveness of the Starclose SE® VCD for hemostasis, following direct 6F antegrade SFA access distal to the femoral head. This prospective, single-center study included patients who were not suitable for CFA puncture and were scheduled to undergo peripheral endovascular interventions using direct antegrade SFA 6F access, at least 2 cm below the inferior edge of femoral head. Hemostasis was obtained with the Starclose SE® VCD (Abbott Laboratories). Primary endpoints were successful hemostasis rate and periprocedural (30-day) major complication rate. Secondary endpoint was the rate of minor complications. Clinical and Doppler ultrasound follow-up was performed at discharge and at one month. Between September 2014 and August 2015, a total of 30 patients (21 male; 70.0%) with a mean body mass index of 41.2 kg/m2 were enrolled. Mean age was 72±9 years (range, 67-88 years). Most patients suffered from critical limb ischemia (87.1%) and diabetes (61.3%). Calcifications were present in eight cases (26.6%). Reason for direct SFA puncture was obesity (100%). Successful hemostasis was achieved in 100% of the cases. No major complications were noted after one-month follow-up. Minor complications included two <5 cm hematomas (6.6%) not necessitating treatment. In this prospective study, Starclose SE® VCD was safe and effective for hemostasis of antegrade direct SFA puncture. Uncomplicated hemostasis was achieved even in cases of puncturing 2 to 7 cm below the inferior edge of the femoral head.

  3. Percutaneous Direct Needle Puncture and Transcatheter N-butyl Cyanoacrylate Injection Techniques for the Embolization of Pseudoaneurysms and Aneurysms of Arteries Supplying the Hepato-pancreato-biliary System and Gastrointestinal Tract

    PubMed Central

    Yadav, Rajanikant R; Boruah, Deb K; Bhattacharyya, Vishwaroop; Prasad, Raghunandan; Kumar, Sheo; Saraswat, V A; Kapoor, V K; Saxena, Rajan

    2016-01-01

    Aims: The aim of this study was to evaluate the safety and clinical efficacy of percutaneous direct needle puncture and transcatheter N-butyl cyanoacrylate (NBCA) injection techniques for the embolization of pseudoaneurysms and aneurysms of arteries supplying the hepato-pancreato-biliary (HPB) system and gastrointestinal (GI) tract. Subjects and Methods: A hospital-based cross-sectional retrospective study was conducted, where the study group comprised 11 patients with pseudoaneurysms/aneurysms of arteries supplying the HPB system and GI tract presenting to a tertiary care center from January 2015 to June 2016. Four patients (36.4%) underwent percutaneous direct needle puncture of pseudoaneurysms with NBCA injection, 3 patients (27.3%) underwent transcatheter embolization with NBCA as sole embolic agent, and in 4 patients (36.4%), transcatheter NBCA injection was done along with coil embolization. Results: This retrospective study comprised 11 patients (8 males and 3 females) with mean age of 35.8 years ± 1.6 (standard deviation [SD]). The mean volume of NBCA: ethiodized oil (lipiodol) mixture injected by percutaneous direct needle puncture was 0.62 ml ± 0.25 (SD) (range = 0.5–1 ml), and by transcatheter injection, it was 0.62 ml ± 0.37 (SD) (range = 0.3–1.4 ml). Embolization with NBCA was technically and clinically successful in all patients (100%). No recurrence of bleeding or recurrence of pseudoaneurysm/aneurysm was noted in our study. Conclusions: Percutaneous direct needle puncture of visceral artery pseudoaneurysms and NBCA glue injection and transcatheter NBCA injection for embolization of visceral artery pseudoaneurysms and aneurysms are cost-effective techniques that can be used when coil embolization is not feasible or has failed. PMID:28123838

  4. Venous access and long-term pacemaker lead failure: comparing contrast-guided axillary vein puncture with subclavian puncture and cephalic cutdown.

    PubMed

    Chan, Ngai-Yin; Kwong, Nim-Pong; Cheong, Adrian-Piers

    2017-07-01

    Existing data on the relationship between venous access and long-term pacemaker lead failure (PLF) are scarce and inconsistent. We aim to study the hypothesis that contrast-guided axillary vein puncture (AP) is better than subclavian puncture (SP) and similar to cephalic vein cutdown (CV) in the incidence of PLF and the success rate of AP is higher than CV. The case records of 409 patients with 681 implantable pacemaker leads were reviewed. Two hundred and fifty-two, 217, and 212 leads were implanted via AP, CV, and SP, respectively. With a mean follow-up of 73.6 ± 33.1 months, 20 (2.9%) PLF occurred. Three (1.2%), 5 (2.3%), and 12 (5.6%) PLF occurred in the AP, CV, and SP groups, respectively. On multivariate Cox regression analysis, the only independent predictor for PLF was the use of SP instead of AP (AP vs. SP; hazard ratio: 0.261; 95% confidence interval: 0.071-0.954, P = 0.042). The success rate of CV (78.2%) was significantly lower than those of AP (97.6%) and SP (96.8%) (P < 0.001). Compared with SP, the use of AP but not CV independently predicted a lower risk of PLF. The success rates in achieving venous accesses were similar between AP and SP, but significantly lower for CV. Axillary vein puncture may thus be considered the venous access of choice for pacemaker lead implantation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  5. [Comparative study of 3 types of lancets for performing prick tests].

    PubMed

    Montalvo, A; Martín, S; Mesa, A; Cortés, C; Rodríguez, M; Laso, M T

    1996-01-01

    Skin Prick Test is considered the cutaneous test of choice in rutinary clinical practice as well as in research. In the last 15 years a large number of lancets for puncture test have been developed looking for a higher level of standardisation and reproducibility. We have compared three lancets, two of them, NeoAbelló (NA) and Dome/Hollister Stier (DHS), used in puncture test and a third one, Blood Lancet (BL), in the modified prick test. Twenty-two patients sensitised to Phleum pratense were tested with the three lancets at three extract concentrations and histamine 10 mg/mL in duplicate. We compared their wheal sizes by means of parallel line assay, their reproducibility, frequency of bleeding wheals, the disturbance for the patient and the correlation between specific IgE and skin response. Wheal size was similar for puncture tests (DHS and NA lancets) and significatively lower than BL, being necessary to increase 1.9 times the extract concentration when using DHS and NA lancets to achieve the same wheal size than when using BL lancets (p < 0.01). Reproducibility with histamine was similar with the three lancets while with the extract was somehow better with puncture tests but without statistical significance. Bleeding was significantly more frequent with BL although this did not influence the results. Less pain was obtained with BL. Finally, correlation with specific IgE was slightly significant for NA and very similar for the other two. With these results in mind we think that any of the three lancets is valid for the diagnostic of the allergic patient. Nevertheless, puncture tests are probably the most suitable at a research level.

  6. Self-force via m-mode regularization and 2+1D evolution: Foundations and a scalar-field implementation on Schwarzschild spacetime

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dolan, Sam R.; Barack, Leor

    2011-01-15

    To model the radiative evolution of extreme mass-ratio binary inspirals (a key target of the LISA mission), the community needs efficient methods for computation of the gravitational self-force (SF) on the Kerr spacetime. Here we further develop a practical 'm-mode regularization' scheme for SF calculations, and give the details of a first implementation. The key steps in the method are (i) removal of a singular part of the perturbation field with a suitable 'puncture' to leave a sufficiently regular residual within a finite worldtube surrounding the particle's worldline, (ii) decomposition in azimuthal (m) modes, (iii) numerical evolution of the mmore » modes in 2+1D with a finite-difference scheme, and (iv) reconstruction of the SF from the mode sum. The method relies on a judicious choice of puncture, based on the Detweiler-Whiting decomposition. We give a working definition for the ''order'' of the puncture, and show how it determines the convergence rate of the m-mode sum. The dissipative piece of the SF displays an exponentially convergent mode sum, while the m-mode sum for the conservative piece converges with a power law. In the latter case, the individual modal contributions fall off at large m as m{sup -n} for even n and as m{sup -n+1} for odd n, where n is the puncture order. We describe an m-mode implementation with a 4th-order puncture to compute the scalar-field SF along circular geodesics on Schwarzschild. In a forthcoming companion paper we extend the calculation to the Kerr spacetime.« less

  7. Physiological and Pathological Impact of Blood Sampling by Retro-Bulbar Sinus Puncture and Facial Vein Phlebotomy in Laboratory Mice

    PubMed Central

    Holst, Birgitte; Hau, Jann; Rozell, Björn; Abelson, Klas Stig Peter

    2014-01-01

    Retro-bulbar sinus puncture and facial vein phlebotomy are two widely used methods for blood sampling in laboratory mice. However, the animal welfare implications associated with these techniques are currently debated, and the possible physiological and pathological implications of blood sampling using these methods have been sparsely investigated. Therefore, this study was conducted to assess and compare the impacts of blood sampling by retro-bulbar sinus puncture and facial vein phlebotomy. Blood was obtained from either the retro-bulbar sinus or the facial vein from male C57BL/6J mice at two time points, and the samples were analyzed for plasma corticosterone. Body weights were measured at the day of blood sampling and the day after blood sampling, and the food consumption was recorded automatically during the 24 hours post-procedure. At the end of study, cheeks and orbital regions were collected for histopathological analysis to assess the degree of tissue trauma. Mice subjected to facial vein phlebotomy had significantly elevated plasma corticosterone levels at both time points in contrast to mice subjected to retro-bulbar sinus puncture, which did not. Both groups of sampled mice lost weight following blood sampling, but the body weight loss was higher in mice subjected to facial vein phlebotomy. The food consumption was not significantly different between the two groups. At gross necropsy, subcutaneous hematomas were found in both groups and the histopathological analyses revealed extensive tissue trauma after both facial vein phlebotomy and retro-bulbar sinus puncture. This study demonstrates that both blood sampling methods have a considerable impact on the animals' physiological condition, which should be considered whenever blood samples are obtained. PMID:25426941

  8. Investigation of Near Shannon Limit Coding Schemes

    NASA Technical Reports Server (NTRS)

    Kwatra, S. C.; Kim, J.; Mo, Fan

    1999-01-01

    Turbo codes can deliver performance that is very close to the Shannon limit. This report investigates algorithms for convolutional turbo codes and block turbo codes. Both coding schemes can achieve performance near Shannon limit. The performance of the schemes is obtained using computer simulations. There are three sections in this report. First section is the introduction. The fundamental knowledge about coding, block coding and convolutional coding is discussed. In the second section, the basic concepts of convolutional turbo codes are introduced and the performance of turbo codes, especially high rate turbo codes, is provided from the simulation results. After introducing all the parameters that help turbo codes achieve such a good performance, it is concluded that output weight distribution should be the main consideration in designing turbo codes. Based on the output weight distribution, the performance bounds for turbo codes are given. Then, the relationships between the output weight distribution and the factors like generator polynomial, interleaver and puncturing pattern are examined. The criterion for the best selection of system components is provided. The puncturing pattern algorithm is discussed in detail. Different puncturing patterns are compared for each high rate. For most of the high rate codes, the puncturing pattern does not show any significant effect on the code performance if pseudo - random interleaver is used in the system. For some special rate codes with poor performance, an alternative puncturing algorithm is designed which restores their performance close to the Shannon limit. Finally, in section three, for iterative decoding of block codes, the method of building trellis for block codes, the structure of the iterative decoding system and the calculation of extrinsic values are discussed.

  9. Management of obstructed balloon catheters.

    PubMed Central

    Browning, G G; Barr, L; Horsburgh, A G

    1984-01-01

    Failure of a balloon catheter to deflate is not uncommon and prevents its removal. Methods of overcoming the problem include traction, bursting the balloon by overinflation, dissolving it with solvents, puncturing it percutaneously with a needle, or puncturing it with a wire stylet passed through the catheter. All except the last technique have major disadvantages and are of questionable safety. Transcatheter puncture of the balloon was used in 16 patients to remove obstructed balloon catheters without any technical difficulty, distress to the patient, or complication. The procedure is safe, simple, and does not require an anaesthetic. If necessary it could be performed safely by nursing or paramedical staff without the patient having to be admitted to hospital. It is the method of choice for the management of this problem. Images FIG 1 FIG 2 FIG 3 FIG 4 PMID:6428691

  10. A new surgical technique for medial collateral ligament balancing: multiple needle puncturing.

    PubMed

    Bellemans, Johan; Vandenneucker, Hilde; Van Lauwe, Johan; Victor, Jan

    2010-10-01

    In this article, we present our experience with a new technique for medial soft tissue balancing, where we make multiple punctures in the medial collateral ligament (MCL) using a 19-gauge needle, to progressively stretch the MCL until a correct ligament balance is achieved. Ligament status was evaluated both before and after the procedure using computer navigation and mediolateral stress testing. The procedure was considered successful when 2 to 4-mm mediolateral joint line opening was obtained in extension and 2 to 6 mm in flexion. In 34 of 35 cases, a progressive correction of medial tightness was achieved according to the above described criteria. One case was considered overreleased in extension. Needle puncturing is a new, effective, and safe technique for progressive correction of MCL tightness in the varus knee. Copyright © 2010 Elsevier Inc. All rights reserved.

  11. [Injuries to blood vessels near the heart caused by central venous catheters].

    PubMed

    Abram, J; Klocker, J; Innerhofer-Pompernigg, N; Mittermayr, M; Freund, M C; Gravenstein, N; Wenzel, V

    2016-11-01

    Injuries to blood vessels near the heart can quickly become life-threatening and include arterial injuries during central venous puncture, which can lead to hemorrhagic shock. We report 6 patients in whom injury to the subclavian artery and vein led to life-threatening complications. Central venous catheters are associated with a multitude of risks, such as venous thrombosis, air embolism, systemic or local infections, paresthesia, hemothorax, pneumothorax, and cervical hematoma, which are not always immediately discernible. The subclavian catheter is at a somewhat lower risk of catheter-associated sepsis and symptomatic venous thrombosis than approaches via the internal jugular and femoral veins. Indeed, access via the subclavian vein carries a substantial risk of pneumo- and hemothorax. Damage to the subclavian vein or artery can also occur during deliberate and inadvertent punctures and result in life-threatening complications. Therefore, careful consideration of the access route is required in relation to the patient and the clinical situation, to keep the incidence of complications as low as possible. For catheterization of the subclavian vein, puncture of the axillary vein in the infraclavicular fossa is a good alternative, because ultrasound imaging of the target vessel is easier than in the subclavian vein and the puncture can be performed much further from the lung.

  12. Comparison of techniques for transdiaphragmatic thoracic drainage after diaphragmatic defect closure in dogs: a cadaveric study

    PubMed Central

    Yoon, Hun-Young; Mann, F. A.; Lee, Suhwon

    2013-01-01

    Four thoracic evacuation techniques for pneumothorax elimination after diaphragmatic defect closure were compared in 40 canine cadavers. After creating a defect in the left side of the diaphragm, thoracic drainage was performed by thoracostomy tube insertion through the defect and a small (DD-SP) or large (DD-LP) puncture created in the caudal mediastinum, or through both the diaphragmatic defect and intact contralateral diaphragm with a small (DI-SP) or large (DI-LP) puncture in made in the caudal mediastinum. Differences in intrapleural pressure (IPP) between the right and left hemithoraxes after air evacuation along with differences in IPP before making a defect and after air evacuation in each hemithorax were calculated. A difference (p ≤ 0.0011) in IPP between the left and right hemithoraxes after air evacuation as well as before making a defect and after air evacuation in the right hemithorax was detected for the DD-SP group. No significant differences (p ≥ 0.0835) were observed for the DI-LP, DD-LP, or DI-SP groups. Creation of a large mediastinal puncture or thoracic evacuation through both a diaphragmatic defect and intact contralateral diaphragm can facilitate proper pneumothorax elimination bilaterally after diaphragmatic defect closure in dogs with a small puncture in the caudal mediastinum. PMID:23814472

  13. Influence of Puncture Site on Radial Artery Occlusion After Transradial Coronary Intervention.

    PubMed

    Bi, Xi-Le; Fu, Xiang-Hua; Gu, Xin-Shun; Wang, Yan-Bo; Li, Wei; Wei, Li-Ye; Fan, Yan-Ming; Bai, Shi-Ru

    2016-04-20

    The risk of radial artery occlusion (RAO) needs particular attention in transradial intervention (TRI). Therefore, reducing vascular occlusion has an important clinical significance. The aim of this study was to determine the appropriate puncture site during TRI through comparing the occurrence of RAO between the different puncture sites to reduce the occurrence of RAO after TRI. We prospectively assessed the occurrence of RAO in 606 consecutive patients undergoing TRI. Artery occlusion was evaluated with Doppler ultrasound in 2 days and 1 year after the intervention. Risk factors for RAO were evaluated using a multivariate model analysis. Of the 606 patients, the RAO occurred in 56 patients. Compared with TRI at 2-5 cm away from the radius styloid process, the odds ratio (OR) for occlusion risk at 0 cm and 1 cm were 9.65 (P = 0.033) and 8.90 (P = 0.040), respectively. The RAO occurred in the ratio of the arterial diameter to the sheath diameter ≤1 (OR = 2.45, P = 0.004). Distal puncture sites (0-1 cm away from the radius styloid process) can lead to a higher rate of RAO. ClinicalTrials.gov, NCT01979627; https://clinicaltrials.gov/ct2/show/NCT01979627?term = NCT01979627 and rank = 1.

  14. Direct puncture embolization of the internal iliac artery during cesarean delivery for pernicious placenta previa coexisting with placenta accreta.

    PubMed

    Chen, Zhenyu; Li, Ju; Shen, Jian; Jin, Jiaxi; Zhang, Wei; Zhong, Wan

    2016-12-01

    To evaluate direct puncture embolization of the internal iliac artery with hemostatic gelatin sponge particles to treat pernicious placenta previa coexisting with placenta accreta during cesarean delivery. A retrospective study was conducted of data from women with pernicious placenta previa and placenta accreta who underwent direct puncture embolization of the internal iliac artery during cesarean delivery at a center in China between September 1, 2013, and February 28, 2015. Information regarding surgical procedures, operative data, and outcomes during hospitalization were obtained from medical records. The procedure was successful in all 16 cases included. Mean operative time was 78 minutes (range 65-90) and mean estimated blood loss was 1550 mL (range 1000-2500). Complications such as fever, buttock pain, or acute limb ischemia were not observed. The procedure was performed after partial cystectomy for two patients with bladder invasion. Postoperative Doppler imaging indicated uterine recovery and normalized uterine blood flow in all patients. Direct puncture embolization of the internal iliac artery during cesarean delivery was a safe, effective, simple, and rapid method to control hemorrhage among women with pernicious placenta previa and placenta accreta. Copyright © 2016 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  15. Comparison of Ultrasonography-Guided Central Venous Catheterization Between Adult and Pediatric Populations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tercan, Fahri; Oguzkurt, Levent; Ozkan, Ugur

    2008-05-15

    The purpose of this study was to compare the technical success and complication rates of ultrasonography-guided central venous catheterization between adult and pediatric patients which have not been reported previously. In a 4-year period, 859 ultrasonography-guided central vein catheterizations in 688 adult patients and 247 catheterizations in 156 pediatric patients were retrospectively evaluated. Mean age was 56.3 years (range, 18 to 95 years) for adults and 3.3 years (range, 0.1 to 16.3 years) for children. The preferred catheterization site was internal jugular vein in 97% of adults and 85% of children. The technical success rate, mean number of punctures, andmore » rate of single wall puncture were 99.4%, 1.04 (range, 1-3), and 83% for adults and 90.3%, 1.25 (range, 1-5), and 49% for children, respectively. All the differences were statistically significant (p < 0.05). Complication rates were 2.3% and 2.4% for adults and children, respectively (p > 0.05). Major complications such as pneumothorax and hemothorax were not seen in any group. In conclusion, ultrasonography-guided central venous catheterization has a high technical success rate, lower puncture attempt rate, and higher single wall puncture rate in adults compared to children. Complication rates are comparable in the two groups.« less

  16. Simultaneous Antegrade-Retrograde Subintimal Revascularization of a Femoropopliteal Chronic Total Occlusion by a Reentry Device-Facilitated Puncture of a Retrogradely Inserted Balloon.

    PubMed

    Goltz, Jan Peter; Anton, Susanne; Wiedner, Marcus; Barkhausen, Jörg; Stahlberg, Erik

    2017-08-01

    To report a rendezvous technique for subintimal revascularization of a chronic total occlusion (CTO) of the superficial femoral artery (SFA). This maneuver is appropriate after failure to cross a long SFA CTO via intra- and subintimal approaches from the ipsilateral femoral as well as retrograde posterior tibial artery (PTA) access sites. After predilation of the subintimal space from the femoral access, a reentry device was placed at the level of the first popliteal artery segment. A balloon was delivered via the retrograde PTA access and inflated at the corresponding level of the reentry device. The balloon was punctured with the needle of the reentry device under fluoroscopic control, and a 0.014-inch guidewire was placed within the punctured balloon. The balloon and the antegrade guidewire were retracted from the retrograde access while the guidewire was gently pushed from the femoral site. Conventional balloon angioplasty of the SFA occlusion was performed via the femoral access, followed by overlapping stent-graft implantation. Complete revascularization of the CTO was documented. In selected cases a transfemoral reentry device-assisted puncture of a retrogradely inserted balloon within the subintimal space may facilitate a rendezvous and revascularization if standard techniques to cross long CTOs have failed.

  17. Spread Spectrum Visual Sensor Network Resource Management Using an End-to-End Cross-Layer Design

    DTIC Science & Technology

    2011-02-01

    Coding In this work, we use rate compatible punctured convolutional (RCPC) codes for channel coding [11]. Using RCPC codes al- lows us to utilize Viterbi’s...11] J. Hagenauer, “ Rate - compatible punctured convolutional codes (RCPC codes ) and their applications,” IEEE Trans. Commun., vol. 36, no. 4, pp. 389...source coding rate , a channel coding rate , and a power level to all nodes in the

  18. A case of transgastric gallbladder puncture as a complication during endoscopic ultrasound-guided drainage of a pancreatic pseudocyst.

    PubMed

    Hikichi, Takuto; Irisawa, Atsushi; Takagi, Tadayuki; Shibukawa, Goro; Wakatsuki, Takeru; Imamura, Hidemichi; Takahashi, Yuta; Sato, Ai; Sato, Masaki; Oyama, Hitoshi; Sato, Naoto; Yamamoto, Go; Mokonuma, Tatsuyuki; Obara, Katsutoshi; Ohira, Hiromasa

    2007-06-01

    A 43-year-old man, a regular drinker, developed a pseudocyst in the pancreatic tail as a result of acutely worsening chronic pancreatitis. Because the pseudocyst, 10 cm in diameter, did not disappear despite conservative treatment, an internal drainage stent was placed transgastrically under endoscopic ultrasound (EUS) guidance. However, cyst infection occurred, and EUS-guided drainage was performed, when the gallbladder was punctured inadvertently. Immediately a nasocystic drain was placed in the gallbladder. Owing to this timely measure, only mild and localized peritonitis developed. Conservative treatment with fasting and an antibiotic was administered, and peritonitis subsided quickly. On the same day, another nasocystic drain was placed for the pancreatic pseudocyst, and it disappeared. As far as we know, this is the first case in which gallbladder puncture was inadvertently performed during EUS-guided drainage of a pancreatic pseudocyst.

  19. Secret information reconciliation based on punctured low-density parity-check codes for continuous-variable quantum key distribution

    NASA Astrophysics Data System (ADS)

    Jiang, Xue-Qin; Huang, Peng; Huang, Duan; Lin, Dakai; Zeng, Guihua

    2017-02-01

    Achieving information theoretic security with practical complexity is of great interest to continuous-variable quantum key distribution in the postprocessing procedure. In this paper, we propose a reconciliation scheme based on the punctured low-density parity-check (LDPC) codes. Compared to the well-known multidimensional reconciliation scheme, the present scheme has lower time complexity. Especially when the chosen punctured LDPC code achieves the Shannon capacity, the proposed reconciliation scheme can remove the information that has been leaked to an eavesdropper in the quantum transmission phase. Therefore, there is no information leaked to the eavesdropper after the reconciliation stage. This indicates that the privacy amplification algorithm of the postprocessing procedure is no more needed after the reconciliation process. These features lead to a higher secret key rate, optimal performance, and availability for the involved quantum key distribution scheme.

  20. Combined Angio-Seal™ and stenting rescue treatment in a case of iatrogenic common carotid artery dissection during direct puncture for ruptured intracranial aneurysm embolization: a technical note.

    PubMed

    Iosif, Christina; Clarençon, Frédéric; Di Maria, Federico; Law-Ye, Bruno; Le Jean, Lise; Capelle, Laurent; Chiras, Jacques; Sourour, Nader

    2013-05-01

    Direct puncture may offer an alternative access for embolization of intracranial aneurysms in patients presenting with tortuous vessels. Nevertheless, major complications such as compressive hematoma and arterial dissection can occur with this technique. A tight common carotid artery (CCA) dissection was seen secondary to direct puncture in a 72-year-old patient who presented with a ruptured anterior communicating artery (ACom) aneurysm. After regular coiling of the aneurysm and using a femoral approach, an Angio-Seal™ device (St Jude Medical, Saint Paul, MN, USA) was placed and a carotid wallstent (Stryker Neurovascular, Fremont, CA, USA) successfully deployed at the dissected CCA, which was followed by good clinical and angiographic outcomes. A combined rescue technique combining Angio-Seal insertion and stent deployment was safe and effective for managing iatrogenic carotid artery dissection. Copyright © 2013. Published by Elsevier Masson SAS.

  1. Bowen-York trumpet data and black-hole simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hannam, Mark; Murchadha, Niall O; Husa, Sascha

    2009-12-15

    The most popular method to construct initial data for black-hole-binary simulations is the puncture method, in which compactified wormholes are given linear and angular momentum via the Bowen-York extrinsic curvature. When these data are evolved, they quickly approach a trumpet topology, suggesting that it would be preferable to use data that are in trumpet form from the outset. To achieve this, we extend the puncture method to allow the construction of Bowen-York trumpets, including an outline of an existence and uniqueness proof of the solutions. We construct boosted, spinning and binary Bowen-York puncture trumpets using a single-domain pseudospectral elliptic solver,more » and evolve the binary data and compare with standard wormhole-data results. We also show that for boosted trumpets the black-hole mass can be prescribed a priori, without recourse to the iterative procedure that is necessary for wormhole data.« less

  2. Healing assessment of tile sets for error tolerance in DNA self-assembly.

    PubMed

    Hashempour, M; Mashreghian Arani, Z; Lombardi, F

    2008-12-01

    An assessment of the effectiveness of healing for error tolerance in DNA self-assembly tile sets for algorithmic/nano-manufacturing applications is presented. Initially, the conditions for correct binding of a tile to an existing aggregate are analysed using a Markovian approach; based on this analysis, it is proved that correct aggregation (as identified with a so-called ideal tile set) is not always met for the existing tile sets for nano-manufacturing. A metric for assessing tile sets for healing by utilising punctures is proposed. Tile sets are investigated and assessed with respect to features such as error (mismatched tile) movement, punctured area and bond types. Subsequently, it is shown that the proposed metric can comprehensively assess the healing effectiveness of a puncture type for a tile set and its capability to attain error tolerance for the desired pattern. Extensive simulation results are provided.

  3. A Kinect(™) camera based navigation system for percutaneous abdominal puncture.

    PubMed

    Xiao, Deqiang; Luo, Huoling; Jia, Fucang; Zhang, Yanfang; Li, Yong; Guo, Xuejun; Cai, Wei; Fang, Chihua; Fan, Yingfang; Zheng, Huimin; Hu, Qingmao

    2016-08-07

    Percutaneous abdominal puncture is a popular interventional method for the management of abdominal tumors. Image-guided puncture can help interventional radiologists improve targeting accuracy. The second generation of Kinect(™) was released recently, we developed an optical navigation system to investigate its feasibility for guiding percutaneous abdominal puncture, and compare its performance on needle insertion guidance with that of the first-generation Kinect(™). For physical-to-image registration in this system, two surfaces extracted from preoperative CT and intraoperative Kinect(™) depth images were matched using an iterative closest point (ICP) algorithm. A 2D shape image-based correspondence searching algorithm was proposed for generating a close initial position before ICP matching. Evaluation experiments were conducted on an abdominal phantom and six beagles in vivo. For phantom study, a two-factor experiment was designed to evaluate the effect of the operator's skill and trajectory on target positioning error (TPE). A total of 36 needle punctures were tested on a Kinect(™) for Windows version 2 (Kinect(™) V2). The target registration error (TRE), user error, and TPE are 4.26  ±  1.94 mm, 2.92  ±  1.67 mm, and 5.23  ±  2.29 mm, respectively. No statistically significant differences in TPE regarding operator's skill and trajectory are observed. Additionally, a Kinect(™) for Windows version 1 (Kinect(™) V1) was tested with 12 insertions, and the TRE evaluated with the Kinect(™) V1 is statistically significantly larger than that with the Kinect(™) V2. For the animal experiment, fifteen artificial liver tumors were inserted guided by the navigation system. The TPE was evaluated as 6.40  ±  2.72 mm, and its lateral and longitudinal component were 4.30  ±  2.51 mm and 3.80  ±  3.11 mm, respectively. This study demonstrates that the navigation accuracy of the proposed system is acceptable, and that the second generation Kinect(™)-based navigation is superior to the first-generation Kinect(™), and has potential of clinical application in percutaneous abdominal puncture.

  4. An imaging anatomical study on percutaneous kyphoplasty for lumbar via a unilateral transverse process-pedicle approach.

    PubMed

    Wang, Song; Wang, Qing; Kang, Jianping; Xiu, Peng; Wang, Gaoju

    2014-04-20

    An imaging anatomical measurement. To investigate the anatomical feasibility of percutaneous kyphoplasty for lumbar osteoporotic vertebral compression fractures via a unilateral transverse process-pedicle approach (TPA). Kyphoplasty via a unilateral approach has been reported and good clinical results have been achieved. However, because of the lack of an anatomical study, these approaches have yet to be popularized. A total of 150 lumbar vertebral bodies of 30 patients were simulated kyphoplasty on the computed tomographic scans through conventional transpedicle approach (CTA) and the TPA, respectively. Anatomical parameters including the distance between the entry point and the midline of the vertebral body, the puncture inclination angle, and the success rate of puncture were measured and compared. The distance between the entry point and the midline from L1 to L5 lumbar levels varied from 20.6 ± 2.2 mm to 28.6 ± 2.9 mm in the CTA group and from 23.6 ± 2.2 mm to 33.6 ± 2.9 mm in the TPA group. The entry point from L1 to L5 in the TPA group was 3.0 ± 2.1 mm to 5.1 ± 2.7 mm more lateral than that in the CTA group. The medial inclination angles from L1 to L5 were 30.2° ± 6.4° to 47.7° ± 5.4° in the TPA and 15.3° ± 6.0° to 22.8° ± 8.7° in the CTA group. The inclination angles in the TPA group were greater than that in the CTA group and the safe range of the puncture angles was also wider. The success rate was 51.7% in the CTA group and 87.7% in the TPA group. The entry point through a TPA was localized at the midline of the transverse process, 3.0 to 5.1 mm outside the lateral margin of the pedicle projection. Compared with CTA, the puncture inclination angle in the TPA approach was much larger with a wider safe puncture range. The TPA approach allowed an easy puncture to meet or surpass the midline of the lumbar vertebral body. N/A.

  5. [Puncture scrotostomy--a treatment method in acute inflammatory diseases of the scrotal organs].

    PubMed

    Shapoval, V I; Asimov, D A; Lesovoĭ, V N

    1989-01-01

    A method for the treatment of acute inflammatory diseases of the scrotal organs by means of puncture scrotostomy, which consists in passing the indwelling micro-irrigator into a cavity of the serous sheath of the testis and epididymis and administration via this route of antibacterial and resolving preparations for 4-5 days, is suggested. A method approved in treatment of 45 patients permits to avoid surgical intervention, and is highly effective.

  6. Software Communications Architecture (SCA) Compliant Software Defined Radio Design for IEEE 802.16 Wirelessman-OFDMTM Transceiver

    DTIC Science & Technology

    2006-12-01

    Convolutional encoder of rate 1/2 (From [10]). Table 3 shows the puncturing patterns used to derive the different code rates . X precedes Y in the order... convolutional code with puncturing configuration (From [10])......11 Table 4. Mandatory channel coding per modulation (From [10...a concatenation of a Reed– Solomon outer code and a rate -adjustable convolutional inner code . At the transmitter, data shall first be encoded with

  7. Presumed Group B Streptococcal Meningitis After Epidural Blood Patch.

    PubMed

    Beilin, Yaakov; Spitzer, Yelena

    2015-06-15

    Bacterial meningitis after epidural catheter placement is rare. We describe a case in which a parturient received labor epidural analgesia for vaginal delivery complicated by dural puncture. The patient developed postdural puncture headache and underwent 2 separate epidural blood patch procedures. She subsequently developed a headache with fever and focal neurologic deficits. She was treated with broad spectrum antibiotics for presumed meningitis, and she made a full recovery. Blood cultures subsequently grew group B streptococcus.

  8. [Management of suspected meningitis in the emergency department].

    PubMed

    Degraeve, Anaïs; Clemente, Marc; Huttner, Benedikt; Rutschmann, Olivier

    2016-08-10

    Febrile meningeal syndrome is a medical emergency. Lumbar puncture keeps its gold-standard status as clinical findings are neither sensitive nor specific enough. Antibiotics and steroids are ideally administered within the first 30 minutes after admission when bacterial meningitis is suspected. A cerebral CT-scan before lumbar puncture is mandatory for selected patients only. PCR for viruses in the cerebrospinal fluid can inform diagnosis and treatment. Meningitis caused by enterovirus can usually be managed at home.

  9. [Ropivacaine use in transnasal sphenopalatine ganglion block for post dural puncture headache in obstetric patients - case series].

    PubMed

    Furtado, Inês; Lima, Isabel Flor de; Pedro, Sérgio

    2018-02-02

    Sphenopalatine ganglion block is widely accepted in chronic pain; however it has been underestimated in post dural puncture headache treatment. The ganglion block does not restore normal cerebrospinal fluid dynamics but effectively reduces symptoms associated with resultant hypotension. When correctly applied it may avoid performance of epidural blood patch. The transnasal approach is a simple and minimally invasive technique. In the cases presented, we attempted to perform and report the ganglion block effectiveness and duration, using ropivacaine. We present four obstetrics patients with post dural puncture headache, after epidural or combined techniques, with Tuohy needle 18G that underwent a safe and successful Sphenopalatine ganglion block. We performed the block 24-48h after dural puncture, with 4mL of ropivacaine 0.75% in each nostril. In three cases pain recurred within 12-48h, although less intense. In one patient a second block was performed with complete relief and without further recurrence. In the other two patients a blood patch was performed without success. All patients were asymptomatic within 7 days. The average duration of analgesic effect of the block remains poorly defined. In the cases reported, blocking with ropivacaine was a simple, safe and effective technique, with immediate and sustained pain relief for at least 12-24h. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  10. No effect of recumbency duration on the occurrence of post-lumbar puncture headache with a 22G cutting needle.

    PubMed

    Kim, Sung R; Chae, Hyun S; Yoon, Mi J; Han, Jung H; Cho, Kwang J; Chung, Sun J

    2012-01-30

    Supine recumbence has been widely performed to prevent post-lumbar puncture headache (PLPH). However, the optimal duration of supine recumbence is controversial. The aim of the study is to compare the occurrence of PLPH according to the duration of supine recumbence in patients with neurological disorders. A non-equivalent control/experimental pre-/post-test study design was used. Seventy consecutive patients were prospectively enrolled between July 2007 and July 2008. Thirty-five patients underwent supine recumbence for four hours after lumbar puncture (Group 1) and 35 patients underwent supine recumbence for one hour (Group 2). The overall frequency of PLPH was 31.4%. The frequency of PLPH was not significantly different between the Group 1 (28.6%) and Group 2 (34.3%) (P = 0.607). In patients with PLPH, the median severity (P = 0.203) and median onset time of PLPH (P = 0.582) were not significantly different between the two groups. In a logistic regression analysis, the previous history of post-lumbar puncture headache was a significant risk factor for the occurrence of PLPH (OR = 11.250, 95% CI: 1.10-114.369, P = 0.041). Our study suggests that short duration (one hour) of supine recumbence may be as efficient as long duration (four hours) of supine recumbence to prevent PLPH.

  11. Engineering Polymer Blends for Impact Damage Mitigation

    NASA Technical Reports Server (NTRS)

    Gordon, Keith L.; Smith, Russell W.; Working, Dennis C.; Siochi, Emilie J.

    2016-01-01

    Structures containing polymers such as DuPont's Surlyn® 8940, demonstrate puncture healing when impacted by a 9 millimeter projectile traveling from speeds near 300 meters per second (1,100 feet per second) to hypervelocity impacts in the micrometeoroid velocity range of 5 kilometers per second (16,000 feet per second). Surlyn® 8940 puncture heals over a temperature range of minus 30 degrees Centigrade to plus 70 degrees Centigrade and shows potential for use in pressurized vessels subject to impact damage. However, such polymers are difficult to process and limited in applicability due to their low thermal stability, poor chemical resistance and overall poor mechanical properties. In this work, several puncture healing engineered melt formulations were developed. Moldings of melt blend formulations were impacted with a 5.56 millimeter projectile with a nominal velocity of 945 meters per second (3,100 feet per second) at about 25 degrees Centigrade, 50 degrees Centigrade and 100 degrees Centigrade, depending upon the specific blend being investigated. Self-healing tendencies were determined using surface vacuum pressure tests and tensile tests after penetration using tensile dog-bone specimens (ASTM D 638-10). For the characterization of tensile properties both pristine and impacted specimens were tested to obtain tensile modulus, yield stress and tensile strength, where possible. Experimental results demonstrate a range of new puncture healing blends which mitigate damage in the ballistic velocity regime.

  12. Experimental and Modeling Studies of Crush, Puncture, and Perforation Scenarios in the Steven Impact Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vandersall, K S; Chidester, S K; Forbes, J W

    2002-06-28

    The Steven test and associated modeling has greatly increased the fundamental knowledge of practical predictions of impact safety hazards for confined and unconfined explosive charges. Building on a database of initial work, experimental and modeling studies of crush, puncture, and perforation scenarios were investigated using the Steven impact test. The descriptions of crush, puncture, and perforation arose from safety scenarios represented by projectile designs that ''crush'' the energetic material or either ''puncture'' with a pinpoint nose or ''perforate'' the front cover with a transportation hook. As desired, these scenarios offer different aspects of the known mechanisms that control ignition: friction,more » shear and strain. Studies of aged and previously damaged HMX-based high explosives included the use of embedded carbon foil and carbon resistor gauges, high-speed cameras, and blast wave gauges to determine the pressure histories, time required for an explosive reaction, and the relative violence of those reactions, respectively. Various ignition processes were modeled as the initial reaction rate expression in the Ignition and Growth reaction rate equations. Good agreement with measured threshold velocities, pressure histories, and times to reaction was calculated for LX-04 impacted by several projectile geometries using a compression dependent ignition term and an elastic-plastic model with a reasonable yield strength for impact strain rates.« less

  13. Shrunk loop theorem for the topology probabilities of closed Brownian (or Feynman) paths on the twice punctured plane

    NASA Astrophysics Data System (ADS)

    Giraud, O.; Thain, A.; Hannay, J. H.

    2004-02-01

    The shrunk loop theorem proved here is an integral identity which facilitates the calculation of the relative probability (or probability amplitude) of any given topology that a free, closed Brownian (or Feynman) path of a given 'duration' might have on the twice punctured plane (plane with two marked points). The result is expressed as a 'scattering' series of integrals of increasing dimensionality based on the maximally shrunk version of the path. Physically, this applies in different contexts: (i) the topology probability of a closed ideal polymer chain on a plane with two impassable points, (ii) the trace of the Schrödinger Green function, and thence spectral information, in the presence of two Aharonov-Bohm fluxes and (iii) the same with two branch points of a Riemann surface instead of fluxes. Our theorem starts from the Stovicek scattering expansion for the Green function in the presence of two Aharonov-Bohm flux lines, which itself is based on the famous Sommerfeld one puncture point solution of 1896 (the one puncture case has much easier topology, just one winding number). Stovicek's expansion itself can supply the results at the expense of choosing a base point on the loop and then integrating it away. The shrunk loop theorem eliminates this extra two-dimensional integration, distilling the topology from the geometry.

  14. Mechanics of anesthetic needle penetration into human sciatic nerve.

    PubMed

    Pichamuthu, Joseph E; Maiti, Spandan; Gan, Maria G; Verdecchia, Nicole M; Orebaugh, Steven L; Vorp, David A

    2018-06-06

    Nerve blocks are frequently performed by anesthesiologists to control pain. For sciatic nerve blocks, the optimal placement of the needle tip between its paraneural sheath and epineurial covering is challenging, even under ultrasound guidance, and frequently results in nerve puncture. We performed needle penetration tests on cadaveric isolated paraneural sheath (IPS), isolated nerve (IN), and the nerve with overlying paraneural sheath (NPS), and quantified puncture force requirement and fracture toughness of these specimens to assess their role in determining the clinical risk of nerve puncture. We found that puncture force (123 ± 17 mN) and fracture toughness (45.48 ± 9.72 J m -2 ) of IPS was significantly lower than those for NPS (1440 ± 161 mN and 1317.46 ± 212.45 Jm -2 , respectively), suggesting that it is not possible to push the tip of the block needle through the paraneural sheath only, without pushing it into the nerve directly, when the sheath is lying directly over the nerve. Results of this study provide a physical basis for tangential placement of the needle as the ideal situation for local anesthetic deposition, as it allows for the penetration of the sheath along the edge of the nerve without entering the epineurium. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. No effect of recumbency duration on the occurrence of post-lumbar puncture headache with a 22G cutting needle

    PubMed Central

    2012-01-01

    Background Supine recumbence has been widely performed to prevent post-lumbar puncture headache (PLPH). However, the optimal duration of supine recumbence is controversial. The aim of the study is to compare the occurrence of PLPH according to the duration of supine recumbence in patients with neurological disorders. Methods A non-equivalent control/experimental pre-/post-test study design was used. Seventy consecutive patients were prospectively enrolled between July 2007 and July 2008. Thirty-five patients underwent supine recumbence for four hours after lumbar puncture (Group 1) and 35 patients underwent supine recumbence for one hour (Group 2). Results The overall frequency of PLPH was 31.4%. The frequency of PLPH was not significantly different between the Group 1 (28.6%) and Group 2 (34.3%) (P = 0.607). In patients with PLPH, the median severity (P = 0.203) and median onset time of PLPH (P = 0.582) were not significantly different between the two groups. In a logistic regression analysis, the previous history of post-lumbar puncture headache was a significant risk factor for the occurrence of PLPH (OR = 11.250, 95% CI: 1.10-114.369, P = 0.041). Conclusions Our study suggests that short duration (one hour) of supine recumbence may be as efficient as long duration (four hours) of supine recumbence to prevent PLPH. PMID:22289169

  16. Optical coefficient measurements using bulk living tissue by an optical fiber puncture with FOV change

    NASA Astrophysics Data System (ADS)

    Nakazawa, Haruna; Doi, Marika; Ogawa, Emiyu; Arai, Tsunenori

    2018-02-01

    To avoid an instability of the optical coefficient measurement using sliced tissue preparation, we proposed the combination of light intensity measurement through an optical fiber puncturing into a bulk tissue varying field of view (FOV) and ray tracing calculation using Monte-Carlo method. The optical coefficients of myocardium such as absorption coefficient μa, scattering coefficient μs, and anisotropic parameter g are used in the myocardium optical propagation. Since optical coefficients obtained using thin sliced tissue could be instable because they are affected by dehydration and intracellular fluid effusion on the sample surface, variety of coefficients have been reported over individual optical differences of living samples. The proposed method which combined the experiment using the bulk tissue with ray tracing calculation were performed. In this method, a 200 μmΦ high-NA silica fiber installed in a 21G needle was punctured up to the bottom of the myocardial bulk tissue over 3 cm in thickness to measure light intensity changing the fiber-tip depth and FOV. We found that the measured attenuation coefficients decreased as the FOV increased. The ray trace calculation represented the same FOV dependence in above mentioned experimental result. We think our particular fiber punctured measurement using bulk tissue varying FOV with Inverse Monte-Carlo method might be useful to obtain the optical coefficients to avoid sample preparation instabilities.

  17. Do the gaps in the ligamentum flavum in the cervical spine translate into dural punctures? An analysis of 4,396 fluoroscopic interlaminar epidural injections.

    PubMed

    Manchikanti, Laxmaiah; Malla, Yogesh; Cash, Kimberly A; Pampati, Vidyasagar

    2015-01-01

    Cervical interlaminar epidural injections are performed frequently in managing chronic neck and upper extremity pain, although less commonly than lumbar interlaminar epidural injections. Recently, the US Food and Drug Administration warnings and safeguards to prevent neurologic complications. These were developed by the Multi-Society Pain Workgroup have taken center stage for all types of epidural injections, including cervical interlaminar epidural injections. The recommendations of safeguards to prevent neurologic complications after epidural steroid injections include that cervical interlaminar epidural injections must be performed utilizing fluoroscopy with anteroposterior, lateral, or oblique views with injection of contrast medium and that entry be limited to the C7-T1 epidural space or occasionally the C6-C7 with requirements for magnetic resonance imaging assessment of the epidural space. To assess the incidence of dural puncture associated with fluoroscopically directed cervical interlaminar epidural injections. A retrospective assessment of patients undergoing cervical interlaminar epidural injections from January 2013 through February 2015. A private interventional pain management practice; a specialty referral center in the United States. The data were collected for 4,396 consecutive cervical interlaminar epidural injections performed from January 2013 through February 2015. The procedures were all performed under fluoroscopic visualization under posteroanterior view with contrast medium injection with lateral view confirmation when indicated. The procedures were performed by one of 2 physicians; the dural puncture and subsequent postoperative complications with level of epidural entry were determined. The outcome was assessment of dural puncture. A review of multiple manuscripts showed that defects in the ligamentum flavum may extend to as much as 100% of the population. However, it also has been shown that among the levels with a gap, the location of a gap in the caudal third of the ligamentum flavum was more frequent than in the middle or cephalic portion of the ligamentum flavum. Among the 4,396 epidural injections performed at C7-T1, C6-C7, and C5-C6, 1,227 were performed at C7-T1; 1,835 were performed at C6-C7; and 1,334 were performed at C5-C6. Dural punctures were observed in 1.8% (24 procedures) at the C5-C6 level entry; 0.87% (16 procedures) at the C6-C7 level entry; and 1.71% (21 procedures) at the C7-T1 level. There was no significant difference among the entry levels. No complications or spinal cord damage or postdural puncture headache were observed. The limitations of this report include that it is an assessment by only 2 well experienced physicians, even though it included a relatively large number of patients. This study illustrates that dural puncture is equally prevalent, though very rare, irrespective of the needle entry level into the epidural space, with an overall dural puncture rate of 1.4%, with 1.8% at the C5-C6 level, 0.87% at the C6-C7 level, and 1.71% at the C7-T1 level. Based on the present literature, it appears that performing the procedure by inserting the needle into the cephalic portion of the intervertebral space rather than the caudal portion may be safer.

  18. Comparison of a GPS needle-tracking system, multiplanar imaging and 2D imaging for real-time ultrasound-guided epidural anaesthesia: A randomized, comparative, observer-blinded study on phantoms.

    PubMed

    Menacé, Cécilia; Choquet, Olivier; Abbal, Bertrand; Bringuier, Sophie; Capdevila, Xavier

    2017-04-01

    The real-time ultrasound-guided paramedian sagittal oblique approach for neuraxial blockade is technically demanding. Innovative technologies have been developed to improve nerve identification and the accuracy of needle placement. The aim of this study was to evaluate three types of ultrasound scans during ultrasound-guided epidural lumbar punctures in a spine phantom. Eleven sets of 20 ultrasound-guided epidural punctures were performed with 2D, GPS, and multiplanar ultrasound machines (660 punctures) on a spine phantom using an in-plane approach. For all punctures, execution time, number of attempts, bone contacts, and needle redirections were noted by an independent physician. Operator comfort and visibility of the needle (tip and shaft) were measured using a numerical scale. The use of GPS significantly decreased the number of punctures, needle repositionings, and bone contacts. Comfort of the physician was also significantly improved with the GPS system compared with the 2D and multiplanar systems. With the multiplanar system, the procedure was not facilitated and execution time was longer compared with 2D imaging after Bonferroni correction but interaction between the type of ultrasound system and mean execution time was not significant in a linear mixed model. There were no significant differences regarding needle tip and shaft visibility between the systems. Multiplanar and GPS needle-tracking systems do not reduce execution time compared with 2D imaging using a real-time ultrasound-guided paramedian sagittal oblique approach in spine phantoms. The GPS needle-tracking system can improve performance in terms of operator comfort, the number of attempts, needle redirections and bone contacts. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  19. Microneedle-based minimally-invasive measurement of puncture resistance and fracture toughness of sclera.

    PubMed

    Park, Seung Hyun; Lee, Kang Ju; Lee, JiYong; Yoon, Jae Hyoung; Jo, Dong Hyun; Kim, Jeong Hun; Kang, Keonwook; Ryu, WonHyoung

    2016-10-15

    The sclera provides the structural support of the eye and protects the intraocular contents. Since it covers a large portion of the eye surface and has relatively high permeability for most drugs, the sclera has been used as a major pathway for drug administration. Recently, microneedle (MN) technology has shown the possibility of highly local and minimally-invasive drug delivery to the eye by MN insertion through the sclera or the suprachoroidal space. Although ocular MN needs to be inserted through the sclera, there has been no systematic study to understand the mechanical properties of the sclera, which are important to design ocular MNs. In this study, we investigated a MN-based method to measure the puncture resistance and fracture toughness of the sclera. To reflect the conditions of MN insertion into the sclera, force-displacement curves obtained from MN-insertion tests were used to estimate the puncture resistance and fracture toughness of sclera tissue. To understand the effect of the insertion conditions, dependency of the mechanical properties on insertion speeds, pre-strain of the sclera, and MN sizes were analyzed and discussed. Measurement of mechanical property of soft biological tissue is challenging due to variations between tissue samples or lack of well-defined measurement techniques. Although non-invasive measurement techniques such as nano/micro indentation were employed to locally measure the elastic modulus of soft biological materials, mechanical properties such as puncture resistance or fracture toughness, which requires "invasive" measurement and is important for the application of "microneedles or hypodermic needles", has not been well studied. In this work, we report minimally-invasive measurement of puncture resistance and fracture toughness of sclera using a double MN insertion method. Parametric studies showed that use of MN proved to be advantageous because of minimally-invasive insertion into tissue as well as higher sensitivity to sub-tissue architecture during the measurement. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  20. Comparison of cutting and pencil-point spinal needle in spinal anesthesia regarding postdural puncture headache

    PubMed Central

    Xu, Hong; Liu, Yang; Song, WenYe; Kan, ShunLi; Liu, FeiFei; Zhang, Di; Ning, GuangZhi; Feng, ShiQing

    2017-01-01

    Abstract Background: Postdural puncture headache (PDPH), mainly resulting from the loss of cerebral spinal fluid (CSF), is a well-known iatrogenic complication of spinal anesthesia and diagnostic lumbar puncture. Spinal needles have been modified to minimize complications. Modifiable risk factors of PDPH mainly included needle size and needle shape. However, whether the incidence of PDPH is significantly different between cutting-point and pencil-point needles was controversial. Then we did a meta-analysis to assess the incidence of PDPH of cutting spinal needle and pencil-point spinal needle. Methods: We included all randomly designed trials, assessing the clinical outcomes in patients given elective spinal anesthesia or diagnostic lumbar puncture with either cutting or pencil-point spinal needle as eligible studies. All selected studies and the risk of bias of them were assessed by 2 investigators. Clinical outcomes including success rates, frequency of PDPH, reported severe PDPH, and the use of epidural blood patch (EBP) were recorded as primary results. Results were evaluated using risk ratio (RR) with 95% confidence interval (CI) for dichotomous variables. Rev Man software (version 5.3) was used to analyze all appropriate data. Results: Twenty-five randomized controlled trials (RCTs) were included in our study. The analysis result revealed that pencil-point spinal needle would result in lower rate of PDPH (RR 2.50; 95% CI [1.96, 3.19]; P < 0.00001) and severe PDPH (RR 3.27; 95% CI [2.15, 4.96]; P < 0.00001). Furthermore, EBP was less used in pencil-point spine needle group (RR 3.69; 95% CI [1.96, 6.95]; P < 0.0001). Conclusions: Current evidences suggest that pencil-point spinal needle was significantly superior compared with cutting spinal needle regarding the frequency of PDPH, PDPH severity, and the use of EBP. In view of this, we recommend the use of pencil-point spinal needle in spinal anesthesia and lumbar puncture. PMID:28383416

  1. Glucosamine Supplementation Demonstrates a Negative Effect On Intervertebral Disc Matrix in an Animal Model of Disc Degeneration

    PubMed Central

    Jacobs, Lloydine; Vo, Nam; Coehlo, J. Paulo; Dong, Qing; Bechara, Bernard; Woods, Barrett; Hempen, Eric; Hartman, Robert; Preuss, Harry; Balk, Judith; Kang, James; Sowa, Gwendolyn

    2013-01-01

    Study Design Laboratory based controlled in vivo study Objective To determine the in vivo effects of oral glucosamine sulfate on intervertebral disc degeneration Summary of Background Data Although glucosamine has demonstrated beneficial effect in articular cartilage, clinical benefit is uncertain. A CDC report from 2009 reported that many patients are using glucosamine supplementation for low back pain (LBP), without significant evidence to support its use. Because disc degeneration is a major contributor of LBP, we explored the effects of glucosamine on disc matrix homeostasis in an animal model of disc degeneration. Methods Eighteen skeletally mature New Zealand White rabbits were divided into four groups: control, annular puncture, glucosamine, and annular puncture+glucosamine. Glucosamine treated rabbits received daily oral supplementation with 107mg/day (weight based equivalent to human 1500mg/day). Annular puncture surgery involved puncturing the annulus fibrosus (AF) of 3 lumbar discs with a 16G needle to induce degeneration. Serial MRIs were obtained at 0, 4, 8, 12, and 20 weeks. Discs were harvested at 20 weeks for determination of glycosaminoglycan(GAG) content, relative gene expression measured by RT-PCR, and histological analyses. Results The MRI index and NP area of injured discs of glucosamine treated animals with annular puncture was found to be lower than that of degenerated discs from rabbits not supplemented with glucosamine. Consistent with this, decreased glycosaminoglycan was demonstrated in glucosamine fed animals, as determined by both histological and GAG content. Gene expression was consistent with a detrimental effect on matrix. Conclusions These data demonstrate that the net effect on matrix in an animal model in vivo, as measured by gene expression, MRI, histology, and total proteoglycan is anti-anabolic. This raises concern over this commonly used supplement, and future research is needed to establish the clinical relevance of these findings. PMID:23324939

  2. Impact of fine needle aspiration (FNA) and of the number of punctures on the feline testis: clinical, gross anatomy and histological assessment.

    PubMed

    Gouletsou, Pagona G; Galatos, Apostolos D; Sideri, Aikaterini I; Kostoulas, Polychronis

    2012-07-01

    The safety of testicular fine needle aspiration (FNA) has been proven in dogs but has not been fully established in men, while studies in rats have given contradictory results. Furthermore, the extent of damage inflicted by multiple punctures is unknown. The aim of this study was to determine the impact of FNA and of the number of punctures on the feline testis with clinical, gross anatomy and histological examinations. Twenty-seven sexually mature healthy laboratory Domestic Shorthair cats were randomly assigned to two groups: 5 cats in which no FNA was performed (control group), and 22 cats which had their left and right testis punctured with a 26 ga needle towards 3 and 8 directions, respectively (experimental group). Two cats at a time were orchiectomized 5 or 30 min, 1, 2, 4, 7 or 14 days or 1, 2, 3 or 4 mo post-aspiration. The cats of the control group were also orchiectomized. During the first week post-aspiration clinical examination revealed vaginal cavity hematoma (8/44 testes), while the histological findings were focal hemorrhagic areas (20/24 testes), erythrocytes inside the seminiferous tubules' lumen (9/24 testes), and germinal cell degeneration in <1.94% of the seminiferous tubules (15/24 testes). After the first week the histological findings were germinal cell degeneration in <2.14% of the seminiferous tubules (19/20 testes) and enlargement of the lumen of <5.16% of the seminiferous tubules (7/20 testes). The germinal epithelium and interstitium had an overall normal appearance. No significant differences were observed between the left and right testis. The results of the study indicate that testicular FNA should be considered a safe procedure in the cat when up to 8 punctures are performed. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. New Coaxial Transseptal Needle for Creation of Atrial Septal Defects in Adult Sheep

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uchida, Barry T.; Pavcnik, Dusan, E-mail: pavcnikd@ohsu.edu; Shimohira, Masashi

    Objectives: To introduce a new transseptal (TS) needle assembled in our laboratory-the coaxial TS (CTS) needle-and describe our experience with it in creating experimental atrial septal defects (ASD) in adult sheep.BackgroundWith commercially available TS needles, we were not able to consistently perform TS puncture at the fossa ovalis in adult sheep.Material and MethodsTen adult sheep with a mean weight of 63.5 kg were used. The CTS needle consists of four components: a 9F Teflon catheter, a 14-gauge blunt curved-tip metal cannula, a 4F tapered catheter, and a 20-gauge open needle. A transjugular 5F pigtail catheter was used to display themore » septal anatomy by angiocardiography and was left in place to mark the level of the fossa ovalis. The septum was then probed by a transfemoral 5F curved-tip end-hole catheter. The CTS needle was aligned with the tip of the transjugular catheter, and the TS puncture was performed under fluoroscopic guidance. After documenting a left atrial position, a balloon angioplasty catheter was used for creation of the ASD. Results: A small patent foramen ovale was discovered by septal probing in one sheep. All sheep underwent successful TS punctures without complications. The ASD size ranged from 13 to 15 mm. In eight sheep, the ASD was in fossa ovalis. In the first two sheep where the needle was not well aligned with the marking catheter, the ASD was in the septum secundum. No damage to the atrial or other heart structures was found at necropsy. Conclusion: The CTS needle is a suitable needle for TS puncture and ASD creation in adult sheep. Proper alignment of the CTS needle with a catheter marking the fossa ovalis is essential for successful puncture.« less

  4. Acupuncture for the Management of Postdural Puncture Headache: A Case Report

    PubMed Central

    Chang, Alexandra; Acquah, Joseph; Reddy, Sanjay

    2016-01-01

    Postdural puncture headache (PDPH) is a recognized complication of neuraxial anesthesia. This case report documents 1 patient who developed PDPH following epidural anesthesia for postoperative pain control. The patient declined conventional treatments, including an epidural blood patch and intravenous caffeine. This report documents successful use of adjunct acupuncture for the management of PDPH. Additional research on acupuncture as a potential adjunctive therapy for PDPH is needed, particularly for patients who are reluctant to receive more invasive treatments. PMID:26937320

  5. Performance Analysis of IEEE 802.11g Waveform Transmitted Over a Fading Channel with Pulse-Noise Interference

    DTIC Science & Technology

    2006-06-01

    called packet binary convolutional code (PBCC), was included as an option for performance at rate of either 5.5 or 11 Mpbs. The second offshoot...and the code rate is r k n= . A general convolutional encoder can be implemented with k shift-registers and n modulo-2 adders. Higher rates can be...derived from lower rate codes by employing “ puncturing .” Puncturing is a procedure for omitting some of the encoded bits in the transmitter (thus

  6. Spinal anaesthesia with 29 gauge Quincke point needles and post dural puncture headache in 2,378 patients.

    PubMed

    Dittmann, M; Schaefer, H G; Renkl, F; Greve, I

    1994-10-01

    Two thousand three hundred and seventy-eight spinal anaesthetics using a 29 G Quincke point needle were administered in a District Hospital between May 1983 and December 1991. The overall post dural puncture headache rate (PDPH) was 1.2% with a maximum of 2.5% in patients between age 30 and 39. PDPH was related to the experience of using 29 G needles (0.5% in consultants versus 2.0% in trainees, P < 0.05).

  7. Diagnostic Lumbar Puncture Among Children With Facial Palsy in a Lyme Disease Endemic Area.

    PubMed

    Paydar-Darian, Niloufar; Kimia, Amir A; Lantos, Paul M; Fine, Andrew M; Gordon, Caroline D; Gordon, Catherine R; Landschaft, Assaf; Nigrovic, Lise E

    2017-06-01

    We identified 620 children with peripheral facial palsy of which 211 (34%) had Lyme disease. The 140 children who had a lumbar puncture performed were more likely to be hospitalized (73% LP performed vs 2% no LP) and to receive parenteral antibiotics (62% LP performed vs 6% no LP). © The Author 2016. Published by Oxford University Press on behalf of The Journal of the Pediatric Infectious Diseases Society. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Transjugular Intrahepatic Portosystemic Shunt Creation in Budd-Chiari Syndrome: Percutaneous Ultrasound-Guided Direct Simultaneous Puncture of the Portal Vein and Vena Cava

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyvat, Fatih, E-mail: boyvatf@yahoo.com; Aytekin, Cueneyt; Harman, Ali

    Budd-Chiari syndrome (BCS) is an uncommon disorder that can be life-threatening, depending on the degree of hepatic venous outflow obstruction. Transjugular intrahepatic portosystemic shunt (TIPS) provides decompression of the congested liver but the hepatic vein obstruction makes the procedure more difficult. We describe a modified method that involved a single percutaneous puncture of the portal vein and inferior vena cava simultaneously for TIPS creation in a patient with BCS.

  9. Foramen ovale puncture, lesioning accuracy, and avoiding complications: microsurgical anatomy study with clinical implications.

    PubMed

    Peris-Celda, Maria; Graziano, Francesca; Russo, Vittorio; Mericle, Robert A; Ulm, Arthur J

    2013-11-01

    Foramen ovale (FO) puncture allows for trigeminal neuralgia treatment, FO electrode placement, and selected biopsy studies. The goals of this study were to demonstrate the anatomical basis of complications related to FO puncture, and provide anatomical landmarks for improvement of safety, selective lesioning of the trigeminal nerve (TN), and optimal placement of electrodes. Both sides of 50 dry skulls were studied to obtain the distances from the FO to relevant cranial base references. A total of 36 sides from 18 formalin-fixed specimens were dissected for Meckel cave and TN measurements. The best radiographic projection for FO visualization was assessed in 40 skulls, and the optimal trajectory angles, insertion depths, and topographies of the lesions were evaluated in 17 specimens. In addition, the differences in postoperative pain relief after the radiofrequency procedure among different branches of the TN were statistically assessed in 49 patients to determine if there was any TN branch less efficiently targeted. Most severe complications during FO puncture are related to incorrect needle placement intracranially or extracranially. The needle should be inserted 25 mm lateral to the oral commissure, forming an approximately 45° angle with the hard palate in the lateral radiographic view, directed 20° medially in the anteroposterior view. Once the needle reaches the FO, it can be advanced by 20 mm, on average, up to the petrous ridge. If the needle/radiofrequency electrode tip remains more than 18 mm away from the midline, injury to the cavernous carotid artery is minimized. Anatomically there is less potential for complications when the needle/radiofrequency electrode is advanced no more than 2 mm away from the clival line in the lateral view, when the needle pierces the medial part of the FO toward the medial part of the trigeminal impression in the petrous ridge, and no more than 4 mm in the lateral part. The 40°/45° inferior transfacial-20° oblique radiographic projection visualized 96.2% of the FOs in dry skulls, and the remainder were not visualized in any other projection of the radiograph. Patients with V1 involvement experienced postoperative pain more frequently than did patients with V2 or V3 involvement. Anatomical targeting of V1 in specimens was more efficiently achieved by inserting the needle in the medial third of the FO; for V2 targeting, in the middle of the FO; and for V3 targeting, in the lateral third of the FO. Knowledge of the extracranial and intracranial anatomical relationships of the FO is essential to understanding and avoiding complications during FO puncture. These data suggest that better radiographic visualization of the FO can improve lesioning accuracy depending on the part of the FO to be punctured. The angles and safety distances obtained may help the neurosurgeon minimize complications during FO puncture and TN lesioning.

  10. Assessment of Navel Oranges, Clementine Tangerines, and Rutaceous Fruits as Hosts of Bactrocera cucurbitae and Bactrocera latifrons (Diptera: Tephritidae)

    PubMed Central

    McQuate, Grant T.; Follett, Peter A.; Liquido, Nicanor J.; Sylva, Charmaine D.

    2015-01-01

    Export of Citrus spp. fruits may require risk mitigation measures if grown in areas with established tephritid fruit fly (Diptera: Tephritidae) populations capable of infesting the fruits. The host status of Citrus spp. fruits is unclear for two tephritid fruit fly species whose geographic ranges have expanded in recent years: melon fly, Bactrocera cucurbitae (Cocquillett), and Bactrocera latifrons (Hendel). In no choice cage infestation studies, B. latifrons oviposited into intact and punctured Washington navel oranges (Citrus sinensis [L.] Osbeck) and Clementine tangerines (C. reticulata L. var. Clementine), but eggs rarely developed to the adult stage. B. cucurbitae readily infested intact and punctured tangerines, and to a lesser extent punctured oranges, but did not infest intact oranges. Limited cage infestation and only a single literature report of field Citrus spp. infestation suggest that risk mitigation of Citrus spp. for B. latifrons is not needed. Risk mitigation options of Citrus spp. for B. cucurbitae, including heat and cold treatments and systems approaches, are discussed. PMID:26816484

  11. Postdural puncture headache

    PubMed Central

    2017-01-01

    Postdural puncture headache (PDPH) is a common complication after inadvertent dural puncture. Risks factors include female sex, young age, pregnancy, vaginal delivery, low body mass index, and being a non-smoker. Needle size, design, and the technique used also affect the risk. Because PDPH can be incapacitating, prompt diagnosis and treatment are mandatory. A diagnostic hallmark of PDPH is a postural headache that worsens with sitting or standing, and improves with lying down. Conservative therapies such as bed rest, hydration, and caffeine are commonly used as prophylaxis and treatment for this condition; however, no substantial evidence supports routine bed rest and aggressive hydration. An epidural blood patch is the most effective treatment option for patients with unsuccessful conservative management. Various other prophylactic and treatment interventions have been suggested. However, due to a lack of conclusive evidence supporting their use, the potential benefits of such interventions should be weighed carefully against the risks. This article reviews the current literature on the diagnosis, risk factors, pathophysiology, prevention, and treatment of PDPH. PMID:28367283

  12. Is the pencil point spinal needle a better choice in younger patients? A comparison of 24G Sprotte with 27G Quincke needles in an unselected group of general surgical patients below 46 years of age.

    PubMed

    Brattebø, G; Wisborg, T; Rodt, S A; Røste, I

    1995-05-01

    Reports have indicated that there are less postoperative complaints after the use of pencil pointed spinal needles. We compared a 24G Sprotte needle with a 27G Quincke needle in a randomised study of 200 healthy patients (49% females), aged 15-46 years. Four patients (2%) reported postdural puncture headache, three with the 24G Sprotte needle and one with the 27G Quincke needle. Thirteen patients (7%) suffered with nonspecific headache, with no significant difference between the two groups. Of the 57 (29%) who reported backpain, a significantly higher proportion had received spinal anaesthesia with the Sprotte needle (OR = 2.06). There was a significantly higher incidence of insufficient blocks after dural puncture with the Sprotte needle. Ease of needle insertion and number of puncture attempts was the same for both needle types.

  13. Tracheobronchial puncture-site nodular reaction (TPNR) following endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA): Systematic review of case reports.

    PubMed

    Madan, Karan; Tiwari, Pavan; Arava, Sudheer; Hadda, Vijay; Mohan, Anant; Guleria, Randeep

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive and efficacious diagnostic modality for lung cancer staging and evaluation of undiagnosed mediastinal lymphadenopathy. Procedure-related complications are uncommon. We herein report an infrequently described phenomenon following EBUS-TBNA in which two patients developed nodular granulation tissue at the tracheobronchial puncture site. On systematic review, we found description of such phenomena by terminologies such as endobronchial inflammatory polyp, granuloma, and endobronchial mass. The endobronchial inflammatory polyp has been one of the most commonly used terminologies for these; but in most cases, the classical features of an inflammatory polyp are lacking. We propose the term, tracheobronchial puncture-site nodular reaction (TPNR) with further classification into granulomatous and nongranulomatous subtypes, for standardized reporting of such reactions following transbronchial needle aspiration procedures. Knowledge of this entity and standardized nomenclature shall help in better characterization of the outcomes and risk factors for the occurrence of these reactions.

  14. Superconformal indices of generalized Argyres-Douglas theories from 2d TQFT

    DOE PAGES

    Song, Jaewon

    2016-02-05

    We present superconformal indices of 4d N = 2 class S theories with certain irregular punctures called type I k,N. This class of theories include generalized Argyres-Douglas theories of type (A k-1, A N-1) and more. We conjecture the superconformal indices in certain simplifi ed limits based on the TQFT structure of the class S theories by writing an expression for the wave function corresponding to the puncture I k,N. We write the Schur limit of the wave function when k and N are coprime. When k = 2, we also conjecture a closed-form expression for the Hall-Littlewood index andmore » the Macdonald index for odd N. From the index, we argue that certain short-multiplet which can appear in the OPE of the stress-energy tensor is absent in the (A 1,A 2n) theory. In addition, we discuss the mixed Schur indices for the N = 1 class S theories with irregular punctures.« less

  15. Venous catheterization with ultrasound navigation

    NASA Astrophysics Data System (ADS)

    Kasatkin, A. A.; Urakov, A. L.; Nigmatullina, A. R.

    2015-11-01

    By ultrasound scanning it was determined that respiratory movements made by chest of healthy and sick person are accompanied by respiratory chest rise of internal jugular veins. During the exhalation of an individual diameter of his veins increases and during the breath it decreases down to the complete disappearing if their lumen. Change of the diameter of internal jugular veins in different phases can influence significantly the results of vein puncture and cauterization in patients. The purpose of this research is development of the method increasing the efficiency and safety of cannulation of internal jugular veins by the ultrasound visualization. We suggested the method of catheterization of internal jugular veins by the ultrasound navigation during the execution of which the puncture of venous wall by puncture needle and the following conduction of J-guide is carried out at the moment of patient's exhalation. This method decreases the risk of complications development during catheterization of internal jugular vein due to exclusion of perforating wound of vein and subjacent tissues and anatomical structures.

  16. Evaluation of two different epidural catheters in clinical practice. narrowing down the incidence of paresthesia!

    PubMed

    Bouman, E A C; Gramke, H F; Wetzel, N; Vanderbroeck, T H T; Bruinsma, R; Theunissen, M; Kerkkamp, H E M; Marcus, M A E

    2007-01-01

    Although epidural anesthesia is considered safe, several complications may occur during puncture and insertion of a catheter. Incidences of paresthesia vary between 0.2 and 56%. A prospective, open, cohort-controlled pilot study was conducted in 188 patients, ASA I-III, age 19-87 years, scheduled for elective surgery and epidural anesthesia. We evaluated a 20 G polyamide (standard) catheter and a 20 G combined polyurethane-polyamide (new) catheter. Spontaneous reactions upon catheter-insertion, paresthesia on questioning, inadvertent dural or intravascular puncture, and reasons for early catheter removal were recorded. The incidence of paresthesia reported spontaneously was 21.3% with the standard catheter and 16.7% with the new catheter. Systematically asking for paresthesia almost doubled the paraesthesia rate. Intravascular cannulation occurred in 5%. No accidental dural punctures occurred. An overall incidence of 13.3% of technical problems led to early catheter removal. The new catheter was at least equivalent to the standard regarding epidural success rate and safety : rate of paresthesia, intravascular and dural cannulation.

  17. Modeling and analysis of film composition on mechanical properties of maize starch based edible films.

    PubMed

    Prakash Maran, J; Sivakumar, V; Thirugnanasambandham, K; Kandasamy, S

    2013-11-01

    The present study investigates the influence of composition (content of maize starch (1-3 g), sorbitol (0.5-1.0 ml), agar (0.5-1.0 g) and tween-80 (0.1-0.5 ml)) on the mechanical properties (tensile strength, elongation, Young's modulus, puncture force and puncture deformation) of the maize starch based edible films using four factors with three level Box-Behnken design. The edible films were obtained by casting method. The results showed that, tween-80 increases the permeation of sorbitol in to the polymer matrix. Increasing concentration of sorbitol (hydrophilic nature and plasticizing effect of sorbitol) decreases the tensile strength, Young's modulus and puncture force of the films. The results were analyzed by Pareto analysis of variance (ANOVA) and second order polynomial models were obtained for all responses with high R(2) values (R(2)>0.95). 3D response surface plots were constructed to study the relationship between process variables and the responses. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Vaccine vial stopper performance for fractional dose delivery of vaccines.

    PubMed

    Jarrahian, Courtney; Myers, Daniel; Creelman, Ben; Saxon, Eugene; Zehrung, Darin

    2017-07-03

    Shortages of vaccines such as inactivated poliovirus and yellow fever vaccines have been addressed by administering reduced-or fractional-doses, as recommended by the World Health Organization Strategic Advisory Group of Experts on Immunization, to expand population coverage in countries at risk. We evaluated 3 kinds of vaccine vial stoppers to assess their performance after increased piercing from repeated withdrawal of doses needed when using fractional doses (0.1 mL) from presentations intended for full-dose (0.5 mL) delivery. Self-sealing capacity and fragmentation of the stopper were assessed via modified versions of international standard protocols. All stoppers maintained self-sealing capacity after 100 punctures. The damage to stoppers measured as the fragmentation rate was within the target of ≤ 10% of punctures resulting in a fragment after as many as 50 punctures. We concluded that stopper failure is not likely to be a concern if existing vaccine vials containing up to 10 regular doses are used up to 50 times for fractional dose delivery.

  19. Venous catheterization with ultrasound navigation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kasatkin, A. A., E-mail: ant-kasatkin@yandex.ru; Nigmatullina, A. R.; Urakov, A. L., E-mail: ant-kasatkin@yandex.ru

    By ultrasound scanning it was determined that respiratory movements made by chest of healthy and sick person are accompanied by respiratory chest rise of internal jugular veins. During the exhalation of an individual diameter of his veins increases and during the breath it decreases down to the complete disappearing if their lumen. Change of the diameter of internal jugular veins in different phases can influence significantly the results of vein puncture and cauterization in patients. The purpose of this research is development of the method increasing the efficiency and safety of cannulation of internal jugular veins by the ultrasound visualization.more » We suggested the method of catheterization of internal jugular veins by the ultrasound navigation during the execution of which the puncture of venous wall by puncture needle and the following conduction of J-guide is carried out at the moment of patient’s exhalation. This method decreases the risk of complications development during catheterization of internal jugular vein due to exclusion of perforating wound of vein and subjacent tissues and anatomical structures.« less

  20. [Assertiveness and peripheral intravenous catheters dwell time with ultrasonography-guided insertion in children and adolescents].

    PubMed

    Avelar, Ariane Ferreira Machado; Peterlini, Maria Angélica Sorgini; da Pedreira, Mavilde Luz Gonçalves

    2013-06-01

    Randomized controlled trial which aimed to verify whether the use of vascular ultrasound (VUS) increases assertiveness in the use of peripheral venous catheter in children, and the catheter dwell time, when compared to traditional puncture. Data were collected after approval of theethical merit. Children and adolescents undergoing VUS-guided peripheral intravenous (GVUS) or puncture guided by clinical assessment of the venous conditions(CG) were included in the study. Significance level was set at p< or =0.05. The sample was composed of 382 punctures, 188 (49.2%) in VUS Gand 194 (50.8%) in CG, performed in 335 children. Assertiveness was found in 73 (71.6%) GVUS catheters and in 84(71.8%) of the CG (p=0.970), and catheter dwell time presented a median of less than one day in both groups (p=0.121), showing nostatistically significant difference. VUS did not significantly influence the results of the dependent variables investigated. ClinicalTrials.govNCT00930254.

  1. Superconformal indices of generalized Argyres-Douglas theories from 2d TQFT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Song, Jaewon

    We present superconformal indices of 4d N = 2 class S theories with certain irregular punctures called type I k,N. This class of theories include generalized Argyres-Douglas theories of type (A k-1, A N-1) and more. We conjecture the superconformal indices in certain simplifi ed limits based on the TQFT structure of the class S theories by writing an expression for the wave function corresponding to the puncture I k,N. We write the Schur limit of the wave function when k and N are coprime. When k = 2, we also conjecture a closed-form expression for the Hall-Littlewood index andmore » the Macdonald index for odd N. From the index, we argue that certain short-multiplet which can appear in the OPE of the stress-energy tensor is absent in the (A 1,A 2n) theory. In addition, we discuss the mixed Schur indices for the N = 1 class S theories with irregular punctures.« less

  2. Fluoroscopy guided percutaneous renal access in prone position

    PubMed Central

    Sharma, Gyanendra R; Maheshwari, Pankaj N; Sharma, Anshu G; Maheshwari, Reeta P; Heda, Ritwik S; Maheshwari, Sakshi P

    2015-01-01

    Percutaneous nephrolithotomy is a very commonly done procedure for management of renal calculus disease. Establishing a good access is the first and probably the most crucial step of this procedure. A proper access is the gateway to success. However, this crucial step has the steepest learning curve for, in a fluoroscopy guided access, it involves visualizing a three dimensional anatomy on a two dimensional fluoroscopy screen. This review describes the anatomical basis of the renal access. It provides a literature review of all aspects of percutaneous renal access along with the advances that have taken place in this field over the years. The article describes a technique to determine the site of skin puncture, the angle and depth of puncture using a simple mathematical principle. It also reviews the common problems faced during the process of puncture and dilatation and describes the ways to overcome them. The aim of this article is to provide the reader a step by step guide for percutaneous renal access. PMID:25789297

  3. Popliteal versus tibial retrograde access for subintimal arterial flossing with antegrade-retrograde intervention (SAFARI) technique.

    PubMed

    Hua, W R; Yi, M Q; Min, T L; Feng, S N; Xuan, L Z; Xing, J

    2013-08-01

    This study aimed to ascertain differences in benefit and effectiveness of popliteal versus tibial retrograde access in subintimal arterial flossing with the antegrade-retrograde intervention (SAFARI) technique. This was a retrospective study of SAFARI-assisted stenting for long chronic total occlusion (CTO) of TASC C and D superficial femoral lesions. 38 cases had superficial femoral artery lesions (23 TASC C and 15 TASC D). All 38 cases underwent SAFARI-assisted stenting. The ipsilateral popliteal artery was retrogradely punctured in 17 patients. A distal posterior tibial (PT) or dorsalis pedis (DP) artery was retrogradely punctured in 21 patients, and 16 of them were punctured after open surgical exposure. SAFARI technical success was achieved in all cases. There was no significant difference in 1-year primary patency (75% vs. 78.9%, p = .86), secondary patency (81.2% vs. 84.2%, p = .91) and access complications (p = 1.00) between popliteal and tibial retrograde access. There was statistical difference in operation time between popliteal (140.1 ± 28.4 min) and tibial retrograde access with PT/DP punctures after surgical vessel exposure (120.4 ± 23.0 min, p = .04). The SAFARI technique is a safe and feasible option for patients with infrainguinal CTO (TASC II C and D). The PT or DP as the retrograde access after surgical vessel exposure is a good choice when using the SAFARI technique. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  4. Veress needle insertion into the left hypochondrium for creation of pneumoperitoneum: diagnostic value of tests to determine the position of the needle in unselected patients.

    PubMed

    Becker, Otávio Monteiro; Azevedo, João Luiz Moreira Coutinho; de Azevedo, Otávio Cansanção; Hypólito, Octávio Henrique Mendes; Miyahira, Susana Abe; Miguel, Gustavo Peixoto Soares; Machado, Afonso Cesar Cabral Guedes

    2011-01-01

    To assess the effectiveness of the Veress needle puncture in the left hypochondrium and the accuracy of the tests described for the intraperitoneal correct positioning of the tip of the Veress needle in an unselected population. Ninetyone patients consecutively scheduled for Videolaparoscopy had the abdominal wall punctured in the left hypochondrium. There were no exclusion criteria. The patients received general anesthesia and mechanical ventilation according to the protocol. After puncturing five tests were used to confirm the positioning of the needle tip within the peritoneal cavity: aspiration test--AT; resistance to infusion--Pres; recovery of the infused fluid--Prec, dripping test--DT, and test of initial intraperitoneal pressure--IIPP. The test results were compared with results from literature for groups with defined exclusion criteria. The results were used for calculating sensitivity (S) specificity (E), positive predictive value (PPV) and negative predictive value (NPV). Inferential statistical methods were used to analyze the findings. There were 13 failures. AT had E = 100% and NPV 100%. Pres had S = 100%, E = 0; PPV = 85.71%; NPV does not apply. Prec: S = 100%, E = 53.84%, PPV = 92.85%, NPV = 100%. DT: S = 100%, E = 61.53%, PPV = 93.97% NPV 100%. In IIPP, S, E, PPV and NPV were 100%. The puncture in the left hypochondrium is effective and the performed tests guide the surgeon regardless of sex, BMI, or previous laparotomy.

  5. Comparison of 25-gauge, Quincke and Whitacre needles for postdural puncture headache in obstetric patients.

    PubMed

    Bano, Fauzia; Haider, Saeeda; Aftab, Sadqa; Sultan, S Tipu

    2004-11-01

    To compare the frequency of postdural puncture headache (PDPH) and failure rate of spinal anesthesia using 25-gauge Quincke and 25-gauge Whitacre needles in obstetric patients. Single blinded, interventional experimental study. This study was conducted at the Department of Anesthesiology, Pain Management and Surgical Intensive Care Unit, Dow University of Health Sciences and Civil Hospital, Karachi from November 1, 2003-April 15, 2004. One hundred females, aged 18-35 years, ASA physical status I and II, with singleton pregnancy undergoing elective or emergency cesarean section under spinal anesthesia were randomly allocated to receive spinal anesthesia either by using 25-gauge Quincke or 25-gauge Whitacre needles. Patients were followed for 3 days postoperatively. Headache, its relation with posture, onset, duration, severity and response to the treatment were recorded. Compared with the Whitacre group, frequency of postdural puncture headache was significantly higher in Quincke group (*p=0.015), while the overall occurrence of non-postdural puncture headache (NPDPH) did not differ significantly between two groups (p=0.736). Most of PDPH developed on 2nd postoperative day, were mild in nature and resolved within 48 hours of their onset. There was no significant difference in the failure rate of spinal anesthesia in both groups (p=0.149). It is suggested that use of 25-gauge Whitacre needle reduces the frequency of PDPH without increasing the failure rate of spinal anesthesia in obstetric patients.

  6. ‘Neanderthal bone flutes’: simply products of Ice Age spotted hyena scavenging activities on cave bear cubs in European cave bear dens

    PubMed Central

    Diedrich, Cajus G.

    2015-01-01

    Punctured extinct cave bear femora were misidentified in southeastern Europe (Hungary/Slovenia) as ‘Palaeolithic bone flutes’ and the ‘oldest Neanderthal instruments’. These are not instruments, nor human made, but products of the most important cave bear scavengers of Europe, hyenas. Late Middle to Late Pleistocene (Mousterian to Gravettian) Ice Age spotted hyenas of Europe occupied mainly cave entrances as dens (communal/cub raising den types), but went deeper for scavenging into cave bear dens, or used in a few cases branches/diagonal shafts (i.e. prey storage den type). In most of those dens, about 20% of adult to 80% of bear cub remains have large carnivore damage. Hyenas left bones in repeating similar tooth mark and crush damage stages, demonstrating a butchering/bone cracking strategy. The femora of subadult cave bears are intermediate in damage patterns, compared to the adult ones, which were fully crushed to pieces. Hyenas produced round–oval puncture marks in cub femora only by the bone-crushing premolar teeth of both upper and lower jaw. The punctures/tooth impact marks are often present on both sides of the shaft of cave bear cub femora and are simply a result of non-breakage of the slightly calcified shaft compacta. All stages of femur puncturing to crushing are demonstrated herein, especially on a large cave bear population from a German cave bear den. PMID:26064624

  7. The Use of ExoSeal Vascular Closure Device for Direct Antegrade Superficial Femoral Artery Puncture Site Hemostasis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rimon, Uri, E-mail: rimonu@sheba.health.gov.il; Khaitovich, Boris, E-mail: borislena@012.net.il; Yakubovich, Dmitry, E-mail: Dmitry.Yakubovitch@sheba.health.gov.il

    2015-06-15

    PurposeThis study was designed to assess the efficacy and safety of the ExoSeal vascular closure device (VCD) to achieve hemostasis in antegrade access of the superficial femoral artery (SFA).MethodsWe retrospectively reviewed the outcome of ExoSeal VCD used for hemostasis in 110 accesses to the SFA in 93 patients between July 2011 and July 2013. All patients had patent proximal SFA based on computer tomography angiography or ultrasound duplex. Arterial calcifications at puncture site were graded using fluoroscopy. The SFA was accessed in an antegrade fashion with ultrasound or fluoroscopic guidance. In all patients, 5–7F vascular sheaths were used. The ExoSealmore » VCD was applied to achieve hemostasis at the end of the procedure. All patients were clinically examined and had ultrasound duplex exam for any puncture site complications during the 24 h postprocedure.ResultsIn all procedures, the ExoSeal was applied successfully. We did not encounter any device-related technical failure. There were four major complications in four patients (3.6 %): three pseudoaneurysms, which were treated with direct thrombin injection, and one hematoma, which necessitated transfusion of two blood units. All patients with complications were treated with anticoagulation preprocedure or received thrombolytic therapy.ConclusionsThe ExoSeal VCD can be safely used for antegrade puncture of the SFA, with a high procedural success rate (100 %) and a low rate of access site complications (3.6 %)« less

  8. Effects of photoperiod on boll weevil (Coleoptera: Curculionidae) development, survival, and reproduction.

    PubMed

    Greenberg, S M; Sappington, T W; Adamczyk, J J; Liu, T-X; Setamou, M

    2008-12-01

    Effects of photoperiod on development, survival, feeding, and oviposition of boll weevils, Anthonomus grandis grandis Boheman, were assessed under five different photophases (24, 14, 12, 10, and 0 h) at a constant 27 degrees C temperature and 65% RH in the laboratory. Analyses of our results detected positive relationships between photoperiod and puncturing (mean numbers of oviposition and feeding punctures per day), and oviposition (oviposition punctures/oviposition+feeding punctures) activities, and the proportion of squares attacked by boll weevil females. When boll weevil females developed in light:darkness cycles, they produced a significantly higher percentage of eggs developing to adulthood than those developed in 24-h light or dark conditions. In long photoperiod (24:0 and 14:10 h), the number of female progeny was significantly higher and their development time was significantly shorter than those developed in short photoperiod (0:24 and 10:14 h). Lifetime oviposition was significantly highest at 12- and 14-h photophase, lowest at 0- and 10-h photophase, and intermediate at 24 h of light. Life table calculations indicated that boll weevil populations developed in a photoperiod of 14:10 and 12:12 (L:D) h will increase an average of two-fold each generation (Ro) compared with boll weevils developed in 24:0- and 10:14-h photoperiods and 15-fold compared with those at 0:24 h. Knowledge of the photoperiod-dependent population growth potential is critical for understanding population dynamics to better develop sampling protocols and timing insecticide applications.

  9. 1.0 T open-configuration magnetic resonance-guided microwave ablation of pig livers in real time

    PubMed Central

    Dong, Jun; Zhang, Liang; Li, Wang; Mao, Siyue; Wang, Yiqi; Wang, Deling; Shen, Lujun; Dong, Annan; Wu, Peihong

    2015-01-01

    The current fastest frame rate of each single image slice in MR-guided ablation is 1.3 seconds, which means delayed imaging for human at an average reaction time: 0.33 seconds. The delayed imaging greatly limits the accuracy of puncture and ablation, and results in puncture injury or incomplete ablation. To overcome delayed imaging and obtain real-time imaging, the study was performed using a 1.0-T whole-body open configuration MR scanner in the livers of 10 Wuzhishan pigs. A respiratory-triggered liver matrix array was explored to guide and monitor microwave ablation in real-time. We successfully performed the entire ablation procedure under MR real-time guidance at 0.202 s, the fastest frame rate for each single image slice. The puncture time ranged from 23 min to 3 min. For the pigs, the mean puncture time was shorted to 4.75 minutes and the mean ablation time was 11.25 minutes at power 70 W. The mean length and widths were 4.62 ± 0.24 cm and 2.64 ± 0.13 cm, respectively. No complications or ablation related deaths during or after ablation were observed. In the current study, MR is able to guide microwave ablation like ultrasound in real-time guidance showing great potential for the treatment of liver tumors. PMID:26315365

  10. A-scan ultrasound system for real-time puncture safety assessment during percutaneous nephrolithotomy

    NASA Astrophysics Data System (ADS)

    Rodrigues, Pedro L.; Rodrigues, Nuno F.; Fonseca, Jaime C.; von Krüger, M. A.; Pereira, W. C. A.; Vilaça, João. L.

    2015-03-01

    Background: Kidney stone is a major universal health problem, affecting 10% of the population worldwide. Percutaneous nephrolithotomy is a first-line and established procedure for disintegration and removal of renal stones. Its surgical success depends on the precise needle puncture of renal calyces, which remains the most challenging task for surgeons. This work describes and tests a new ultrasound based system to alert the surgeon when undesirable anatomical structures are in between the puncture path defined through a tracked needle. Methods: Two circular ultrasound transducers were built with a single 3.3-MHz piezoelectric ceramic PZT SN8, 25.4 mm of radius and resin-epoxy matching and backing layers. One matching layer was designed with a concave curvature to work as an acoustic lens with long focusing. The A-scan signals were filtered and processed to automatically detect reflected echoes. Results: The transducers were mapped in water tank and tested in a study involving 45 phantoms. Each phantom mimics different needle insertion trajectories with a percutaneous path length between 80 and 150 mm. Results showed that the beam cross-sectional area oscillates around the ceramics radius and it was possible to automatically detect echo signals in phantoms with length higher than 80 mm. Conclusions: This new solution may alert the surgeon about anatomical tissues changes during needle insertion, which may decrease the need of X-Ray radiation exposure and ultrasound image evaluation during percutaneous puncture.

  11. Subdural Hematoma Associated With Labor Epidural Analgesia: A Case Series

    PubMed Central

    Lim, Grace; Zorn, Jamie M.; Dong, Yuanxu J.; DeRenzo, Joseph S.; Waters, Jonathan H.

    2016-01-01

    Objective This report describes the characteristics and impact of subdural hematoma (SDH) after labor epidural analgesia. Case Reports Eleven obstetric patients had subdural hematomas (SDH) associated with the use of labor epidural analgesia over 7 years at a tertiary care hospital. Ten of 11 patients had signs consistent with post-dural puncture headache (PDPH) prior to the diagnosis of SDH. Five patients (45%) had a recognized unintentional dural puncture, 1 (9%) had a combined spinal-epidural with a 24-gauge needle, and 5 (45%) had no recognized dural puncture. For 10 of the 11 cases, SDH was diagnosed an average of 4.1 (range 1–7) days after performance of labor epidural analgesia; one case was diagnosed at 25 days. Ten of 11 (91%) cases had a second hospital stay for an average of 2.8 (range 2–4) days for observation, without further requirement for neurosurgical intervention. One case (9%) had decompressive hemicraniectomy after becoming unresponsive. The observed rate of labor epidural analgesia-associated SDH was 0.026% (11 in 42,969, about 1:3900), and the rate of SDH was 1.1% (5 in 437, about 1:87) if a recognized dural puncture occurred during epidural catheter placement. Conclusions SDH after labor epidural anesthesia is rare, but potentially more common than historically estimated. Cases of PDPH after labor epidural anesthesia should be monitored closely for severe neurologic signs and symptoms that could herald SDH. PMID:27512937

  12. A comparative study of bio-inspired protective scales using 3D printing and mechanical testing.

    PubMed

    Martini, Roberto; Balit, Yanis; Barthelat, Francois

    2017-06-01

    Flexible natural armors from fish, alligators or armadillo are attracting an increasing amount of attention for their unique combinations of hardness, flexibility and light weight. The extreme contrast of stiffness between hard scales and surrounding soft tissues gives rise to unusual and attractive mechanisms, which now serve as models for the design of bio-inspired armors. Despite this growing interest, there is little guideline for the choice of materials, optimum thickness, size, shape and arrangement for the protective scales. In this work, we explore how the geometry and arrangement of hard scales can be tailored to promote scale-scale interactions. We use 3D printing to fabricate arrays of scales with increasingly complex geometries and arrangements, from simple squares with no overlap to complex ganoid-scales with overlaps and interlocking features. We performed puncture tests and flexural tests on each of the 3D printed materials, and we report the puncture resistance - compliance characteristics of each design on an Ashby chart. The interactions between the scales can significantly increase the resistance to puncture, and these interactions can be maximized by tuning the geometry and arrangement of the scales. Interestingly, the designs that offer the best combinations of puncture resistance and flexural compliance are similar to the geometry and arrangement of natural teleost and ganoid scales, which suggests that natural evolution has shaped these systems to maximize flexible protection. This study yields new insights into the mechanisms of natural dermal armor, and also suggests new designs for personal protective systems. Flexible natural armors from fishes, alligators or armadillos are attracting an increasing amount of attention for their unique and attractive combinations of hardness, flexibility and low weight. Despite a growing interest in bio-inspired flexible protection, there is still little guideline for the choice of materials, optimum thickness, size, shape and arrangement of the protective scales. In this work, we explore how the geometry and arrangement of hard scales affect puncture resistance and flexural compliance, using 3D printing and mechanical testing. Our main finding is that the performance of the scaled skin in terms of puncture resistance can be significantly improved by slight changes in their geometry and arrangement. Our results also suggest that natural evolution has shaped scaled skins to maximize flexible protection. This study yields new insights into the mechanics of natural dermal armors, and also suggests new designs for personal protective systems. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  13. In Vitro Activities of ABT-492, a New Fluoroquinolone, against 155 Aerobic and 171 Anaerobic Pathogens Isolated from Antral Sinus Puncture Specimens from Patients with Sinusitis

    PubMed Central

    Goldstein, Ellie J. C.; Citron, Diane M.; Merriam, C. Vreni; Warren, Yumi A.; Tyrrell, Kerin L.; Fernandez, Helen T.

    2003-01-01

    ABT-492 exhibited excellent in vitro activities against all 326 aerobic and anaerobic antral puncture sinus isolates tested with MICs (in micrograms per milliliter) at which 90% of the isolates tested were inhibited as follows: Haemophilus influenzae, 0.001; Moraxella catarrhalis, 0.008; and Streptococcus pneumoniae, 0.015. It was four- to sixfold more active than other fluoroquinolones, including against levofloxacin-resistant strains of S. pneumoniae, methicillin-resistant Staphylococcus aureus, and Prevotella species. PMID:12937015

  14. In vitro activities of ABT-492, a new fluoroquinolone, against 155 aerobic and 171 anaerobic pathogens isolated from antral sinus puncture specimens from patients with sinusitis.

    PubMed

    Goldstein, Ellie J C; Citron, Diane M; Merriam, C Vreni; Warren, Yumi A; Tyrrell, Kerin L; Fernandez, Helen T

    2003-09-01

    ABT-492 exhibited excellent in vitro activities against all 326 aerobic and anaerobic antral puncture sinus isolates tested with MICs (in micrograms per milliliter) at which 90% of the isolates tested were inhibited as follows: Haemophilus influenzae, 0.001; Moraxella catarrhalis, 0.008; and Streptococcus pneumoniae, 0.015. It was four- to sixfold more active than other fluoroquinolones, including against levofloxacin-resistant strains of S. pneumoniae, methicillin-resistant Staphylococcus aureus, and Prevotella species.

  15. Non-polynomial closed string field theory: loops and conformal maps

    NASA Astrophysics Data System (ADS)

    Hua, Long; Kaku, Michio

    1990-11-01

    Recently, we proposed the complete classical action for the non-polynomial closed string field theory, which succesfully reproduced all closed string tree amplitudes. (The action was simultaneously proposed by the Kyoto group). In this paper, we analyze the structure of the theory. We (a) compute the explicit conformal map for all g-loop, p-puncture diagrams, (b) compute all one-loop, two-puncture maps in terms of hyper-elliptic functions, and (c) analyze their modular structure. We analyze, but do not resolve, the question of modular invariance.

  16. [Effect of tiapride on the side effects of cerebrospinal fluid depletions in spinal puncture, pneumoencephalography and air myelography].

    PubMed

    Zenglein, J P; Baldauf, E; Wasser, P h

    1978-04-01

    The authors report their experience of the treatment post-cerebrospinal fluid loss syndrom, following subtraction by lumbar puncture, pneumoencephalography and air myelography. The study of 70 patients, divided in two equal groups, one receiving classic therapy, one receiving tiapride, a new molecule of original conception, lead to emphasize the interest of this drug. Tolerance in general is good, despite the administration of high doses and effects on the syndrom are positive and remarkable in preventive and curative treatment.

  17. Can Diastat Grafts Meet the Challenges of Daily Punctures?

    PubMed

    Chandran, Prem K G; Messer, Diane; Sidwell, Richard A; Stubbs, David H; Nish, Andrew D

    1997-01-01

    To determine whether Diastat grafts can meet the challenges of daily needle punctures required for home hemodialysis (HD), a retrospective analysis was performed on the experience with 47 grafts placed in 44 patients receiving HD three times a week. The control group consisted of 17 patients who received 17 stretch polytetrafluoroethylene (s-PTFE) grafts. Apart from their ability to better contain bleeding after needle withdrawal, in all measures of longevity the Diastat grafts were outperformed by the s-PTFE grafts. No more direct data exist to address the original challenge.

  18. The effect of direct heating and cooling of heat regulation centers on body temperature

    NASA Technical Reports Server (NTRS)

    Barbour, H. G.

    1978-01-01

    Experiments were done on 28 rabbits in which puncture instruments were left in the brain for 1-2 days until the calori-puncture hyperthermia had passed and the body temperature was again normal. The instrument remaining in the brain was then used as a galvanic electrode and a second fever was produced, this time due to the electrical stimulus. It was concluded that heat is a centrally acting antipyretic and that cold is a centrally acting stimulus which produces hyperpyrexia cold-induced fever.

  19. Impression Testing of Self-Healing Polymers

    NASA Technical Reports Server (NTRS)

    Hinkley, Jeffrey A.; Huber, Amy

    2005-01-01

    As part of the BIOSANT program (biologically-inspired smart nanotechnology), scientists at NASA-Langley have identified a "self-healing" plastic that spontaneously closes the hole left by the passage of a bullet. To understand and generalize the phenomenon in question, the mechanical properties responsible for this ability are being explored. Low-rate impression testing was chosen to characterize post-yield material properties, and it turned out that materials that heal following ballistic puncture also show up to 80% healing of the low-rate impression. Preliminary results on the effects of temperature and rate of puncture are presented.

  20. Unenhanced low-dose versus standard-dose CT localization in patients with upper urinary calculi for minimally invasive percutaneous nephrolithotomy (MPCNL)

    PubMed Central

    Licheng, Jiang; Yidong, Fan; Ping, Wang; Keqiang, Yan; Xueting, Wang; Yingchen, Zhang; Lei, Gao; Jiyang, Ding; Zhonghua, Xu

    2014-01-01

    Background & objectives: With the ethical concern about the dose of CT scan and wide use of CT in protocol of suspected renal colic, more attention has been paid to low dose CT. The aim of the present study was to make a comparison of unenhanced low-dose spiral CT localization with unenhanced standard-dose spiral CT in patients with upper urinary tract calculi for minimally invasive percutaneous nephrolithotomy (MPCNL) treatment. Methods: Twenty eight patients with ureter and renal calculus, preparing to take MPCNL, underwent both abdominal low-dose CT (25 mAs) and standard-dose CT (100 mAs). Low-dose CT and standard-dose CT were independently evaluated for the characterization of renal/ureteral calculi, perirenal adjacent organs, blood vessels, indirect signs of renal or ureteral calculus (renal enlargement, pyeloureteral dilatation), and the indices of localization (percutaneous puncture angulation and depth) used in the MPCNL procedure. Results: In all 28 patients, low-dose CT was 100 per cent coincidence 100 per cent sensitive and 100 per cent specific for depicting the location of the renal and ureteral calculus, renal enlargement, pyeloureteral dilatation, adjacent organs, and the presumptive puncture point and a 96.3 per cent coincidence 96 per cent sensitivity and 93 per cent specificity for blood vessel signs within the renal sinus, and with an obvious lower radiation exposure for patients when compared to standard-dose CT (P<0.05). The indices of puncture depth, puncture angulation, and maximum calculus transverse diameter on the axial surface showed no significant difference between the two doses of CT scans, with a significant variation in calculus visualization slice numbers (P<0.05). Interpretation & conclusions: Our findings show that unenhanced low-dose CT achieves a sensitivity and accuracy similar to that of standard-dose CT in assessing the localization of renal ureteral calculus and adjacent organs conditions and identifying the maximum calculus transverse diameter on the axial surface, percutaneous puncture depth, and angulation in patients, with a significant lower radiation exposure, who are to be treated by MPCNL, and can be used as an alternative localization method. PMID:24820832

  1. Unenhanced low-dose versus standard-dose CT localization in patients with upper urinary calculi for minimally invasive percutaneous nephrolithotomy (MPCNL).

    PubMed

    Licheng, Jiang; Yidong, Fan; Ping, Wang; Keqiang, Yan; Xueting, Wang; Yingchen, Zhang; Lei, Gao; Jiyang, Ding; Zhonghua, Xu

    2014-03-01

    With the ethical concern about the dose of CT scan and wide use of CT in protocol of suspected renal colic, more attention has been paid to low dose CT. The aim of the present study was to make a comparison of unenhanced low-dose spiral CT localization with unenhanced standard-dose spiral CT in patients with upper urinary tract calculi for minimally invasive percutaneous nephrolithotomy (MPCNL) treatment. Twenty eight patients with ureter and renal calculus, preparing to take MPCNL, underwent both abdominal low-dose CT (25 mAs) and standard-dose CT (100 mAs). Low-dose CT and standard-dose CT were independently evaluated for the characterization of renal/ureteral calculi, perirenal adjacent organs, blood vessels, indirect signs of renal or ureteral calculus (renal enlargement, pyeloureteral dilatation), and the indices of localization (percutaneous puncture angulation and depth) used in the MPCNL procedure. In all 28 patients, low-dose CT was 100 per cent coincidence 100 per cent sensitive and 100 per cent specific for depicting the location of the renal and ureteral calculus, renal enlargement, pyeloureteral dilatation, adjacent organs, and the presumptive puncture point and a 96.3 per cent coincidence 96 per cent sensitivity and 93 per cent specificity for blood vessel signs within the renal sinus, and with an obvious lower radiation exposure for patients when compared to standard-dose CT (P<0.05). The indices of puncture depth, puncture angulation, and maximum calculus transverse diameter on the axial surface showed no significant difference between the two doses of CT scans, with a significant variation in calculus visualization slice numbers (P<0.05). Our findings show that unenhanced low-dose CT achieves a sensitivity and accuracy similar to that of standard-dose CT in assessing the localization of renal ureteral calculus and adjacent organs conditions and identifying the maximum calculus transverse diameter on the axial surface, percutaneous puncture depth, and angulation in patients, with a significant lower radiation exposure, who are to be treated by MPCNL, and can be used as an alternative localization method.

  2. Significance of preoperative planning software for puncture and channel establishment in percutaneous endoscopic lumbar DISCECTOMY: A study of 40 cases.

    PubMed

    Hu, Zhouyang; Li, Xinhua; Cui, Jian; He, Xiaobo; Li, Cong; Han, Yingchao; Pan, Jie; Yang, Mingjie; Tan, Jun; Li, Lijun

    2017-05-01

    Preoperative planning software has been widely used in many other minimally invasive surgeries, but there is a lack of information describing the clinical benefits of existing software applied in percutaneous endoscopic lumbar discectomy (PELD). This study aimed to compare the clinical efficacy of preoperative planning software in puncture and channel establishment of PELD with routine methods in treating lumbar disc herniation (LDH). From June 2016 to October 2016, 40 patients who had single L4/5 or L5/S1 disc herniation were divided into two groups. Group A adopted planning software for preoperative puncture simulation while Group B took routine cases discussion for making puncture plans. The channel establishment time, operative time, fluoroscopic times and complications were compared between the two groups. The surgical efficacy was evaluated according to the Visual Analogue Scale (VAS), Oswestry Disability Index (ODI) and modified Macnab's criteria. The mean channel establishment time was 25.1 ± 4.2 min and 34.6 ± 5.4 min in Group A and B, respectively (P < 0.05). The mean operative time was 80.8 ± 8.4 min and 92.1 ± 7.3 min in Group A and B, respectively (P < 0.05). The fluoroscopic times were 21.5 ± 5.2 in Group A and 29.3 ± 5.5 in Group B (P < 0.05). There were no significant differences in VAS and ODI scorings between the two groups either preoperatively or postoperatively (P > 0.05). The findings of modified Macnab's criteria at each follow-up also showed no significant differences (P > 0.05). The application of preoperative planning software in puncture and cannula insertion planning in PELD was easy and reliable, and could reduce the channel establishment time, operative time and fluoroscopic times of PELD significantly. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  3. Surgical glove perforation in cardiac surgery.

    PubMed

    Driever, R; Beie, M; Schmitz, E; Holland, M; Knapp, M; Reifschneider, H J; Hofmann, F; Vetter, H O

    2001-12-01

    Recently, concern for the protection of health care employees and health care recipients has led to increasing awareness of transmitted infections. Sterile surgical gloves were tested to determine the incidence of perforations after being worn during procedures commonly performed by cardiac surgeons. In a prospective study conducted from January 15, 2000 through February 15, 2000, 953 gloves worn during cardiac surgery were evaluated for punctures. Pairs of sterile latex surgical gloves were collected over a period of one month. Routine tasks included mainly bypass and valve surgery. Impermeability was tested by means of a water retention test according to European standard EN 455 Part 1 performed on 954 (Manufix, Hartmann, Germany) latex gloves. A control group of 50 unused gloves was also evaluated for the presence of spontaneous leakage. Gloves were separated according to whether the wearer was an operator (254 gloves), first assistant (220 gloves), second assistant (272 gloves), or theatre nurse (207 gloves). Gloves with a known perforation occurring during the procedure were not included in the study. There were no punctures in the 50 unused gloves. Punctures were detected in 66 of 254 (26.0 %) gloves used by operators, 49 of 220 (22.3 %) used by first assistants, 25 of 272 (9.2 %) used by second assistants, and 78 of 207 (37.7 %) used by theatre nurses. Some gloves had more than one puncture, accounting for the 244 holes detected (operators 75/244 = 30.7 %; first assistants 54/244 = 22.1 %; second assistants 28/244 = 11.5 %; theatre nurses 87/244 = 35.7 %). Sites of scalpel and suture needle injuries were most commonly the thumb (27.3 %) and pointer finger (42.1 %) of the non-dominant hand, followed by, in descending order: middle finger (10.2 %), other fingers (15.7 %), palm (3.8 %) and back of the hand (0.9 %). The number of punctures that occur during cardiac operations is obviously higher than has so far been assumed. Therefore, cardiac surgeons should consider the incidence of unknown glove perforations when planning surgery in patients with infectious diseases.

  4. Comparison of 4 different types of surgical gloves used for preventing blood contact.

    PubMed

    Wittmann, Andreas; Kralj, Nenad; Köver, Jan; Gasthaus, Klaus; Lerch, Hartmut; Hofmann, Friedrich

    2010-05-01

    Needlestick injuries are always associated with a risk of infection, because these types of punctures may expose healthcare workers to a patient's blood and/or body fluids. To compare the efficacy of 4 different types of surgical gloves for preventing exposure to blood as a result of needlestick injury. For simulation of needlestick injury, a circular sample of pork skin was tightened onto a bracket, and a single finger from a medical glove was stretched over the sample. First, a powder-free surgical glove with a gel coating was used to test blood contact. Second, a glove with a patented puncture indication system was used to test blood contact with a double-gloved hand. Third, 2 powder-free latex medical gloves of the same size and hand were combined for double gloving, again to test blood contact. Finally, we tested a glove with an integrated disinfectant on the inside. The punctures were carried out using diverse sharp surgical devices that were contaminated with (99)Tc-marked blood. The amount of blood contact was determined from the transmitted radioactivity. For the powder-free surgical glove with a gel coating, a mean volume of 0.048 microL of blood (standard error of the mean [SEM], 0.077 microL) was transferred in punctures with an automated lancet at a depth of 2.4 mm through 1 layer of latex. For the glove with an integrated disinfectant on the inside, the mean volume of blood transferred was 0.030 microL (SEM, 0.0056 microL) with a single glove and was 0.024 microL (SEM, 0.003 microL) with 2 gloves. For the glove with the patented puncture indication system, a mean volume of 0.024 microL (SEM, 0.003 microL) of blood was transferred. Double gloving or the use of a glove with disinfectant can result in a decrease in the volume of blood transferred. Therefore, the use of either of these gloving systems could help to minimize the risk of bloodborne infections for medical staff.

  5. Intraosseous anesthesia in hemodynamic studies in children with cardiopathy.

    PubMed

    Aliman, Ana Cristina; Piccioni, Marilde de Albuquerque; Piccioni, João Luiz; Oliva, José Luiz; Auler Júnior, José Otávio Costa

    2011-01-01

    Intraosseous (IO) access has been used with good results in emergency situations, when venous access is not available for fluids and drugs infusion. The objective of this study was to evaluate IO a useful technique for anesthesia and fluids infusion during hemodynamic studies and when peripheral intravascular access is unobtainable. The setting was an university hospital hemodynamics unit, and the subjects were twenty one infants with congenital heart disease enrolled for elective hemodynamic study diagnosis. This study compared the effectiveness of IO access in relation to IV access for infusion of anesthetics agents (ketamine, midazolam, and fentanyl) and fluids during hemodynamic studies. The anesthetic induction time, procedure duration, anesthesia recovery time, adequate hydration, and IV and IO puncture complications were compared between groups. The puncture time was significantly smaller in IO group (3.6 min) that in IV group (9.6 min). The anesthetic onset time (56.3 second) for the IV group was faster than IO group (71.3 second). No significant difference between groups were found in relation to hydration (IV group, 315.5 mL vs IO group, 293.2 mL), and anesthesia recovery time (IO group, 65.2 min vs IV group, 55.0 min). The puncture site was reevaluated after 7 and 15 days without signs of infection or other complications. Results showed superiority for IO infusion when considering the puncture time of the procedure. Due to its easy manipulation and efficiency, hydration and anesthesia by IO access was satisfactory for hemodynamic studies without the necessity of other infusion access. Copyright © 2011 Elsevier Editora Ltda. All rights reserved.

  6. The effects of needle deformation during lumbar puncture.

    PubMed

    Özdemir, Hasan Hüseyin; Demir, Caner F; Varol, Sefer; Arslan, Demet; Yıldız, Mustafa; Akil, Eşref

    2015-01-01

    The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP). Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1%) of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3%) of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%). Forty-seven (41.5%) patients experienced post lumbar puncture headache (PLPH) and 13 (11.5%) patients experienced intracranial hypotension (IH). No statistically significant correlation between the degree of deflection and headache was found (P > 0.05). Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH.

  7. Venous vascular malformations of the craniofacial region: pre-operative embolisation with direct percutaneous puncture and N-butyl cyanoacrylate.

    PubMed

    Cil, B E; Vargel, I; Geyik, S; Peynircioglu, B; Cavusoglu, T

    2008-12-01

    Craniofacial venous vascular malformations cause severe cosmetic problems and yet these lesions are not candidates for transcatheter embolisation owing to the lack of arterial feeders. The purpose of this study was to evaluate the effectiveness of pre-operative embolisation of these lesions with N-butyl 2-cyanoacrylate (NBCA) via direct puncture. Between September 2003 and April 2006, 13 patients (7 female; age range, 6-64 years; mean, 16.7 years) were embolised with direct puncture and injection of NBCA. All of the patients were referred from plastic surgery with an operational plan. Angiography performed in all patients showed no or little arterial staining. NBCA diluted with iodized oil at a ratio of 1:6 (18%) was injected via a percutaneously placed 21 gauge needle. Complete embolisation was achieved in 8 patients and partial embolisation in the remaining 5. A total of 18 sessions of embolisation were performed on 13 patients. Nine patients underwent only one embolisation session, three patients underwent two sessions and only one patient underwent three sessions. The mean volume of NBCA used per session was 5.8 ml, ranging from 1-12 ml. All patients underwent a successful surgical resection to improve cosmetic disfigurement within 10-15 days after the embolisation procedure. Mean follow-up time was 22 months. One patient experienced skin necrosis on her nose after embolisation. No other complications related to the procedure were observed. In conclusion, pre-operative NBCA embolisation with direct puncture is a safe and easy procedure. It can increase the success of the surgical treatment of these lesions.

  8. Feasibility of an endotracheal tube-mounted camera for percutaneous dilatational tracheostomy.

    PubMed

    Grensemann, J; Eichler, L; Hopf, S; Jarczak, D; Simon, M; Kluge, S

    2017-07-01

    Percutaneous dilatational tracheostomy (PDT) in critically ill patients is often led by optical guidance with a bronchoscope. This is not without its disadvantages. Therefore, we aimed to study the feasibility of a recently introduced endotracheal tube-mounted camera (VivaSight™-SL, ET View, Misgav, Israel) in the guidance of PDT. We studied 10 critically ill patients who received PDT with a VivaSight-SL tube that was inserted prior to tracheostomy for optical guidance. Visualization of the tracheal structures (i.e., identification and monitoring of the thyroid, cricoid, and tracheal cartilage and the posterior wall) and the quality of ventilation (before puncture and during the tracheostomy) were rated on four-point Likert scales. Respiratory variables were recorded, and blood gases were sampled before the interventions, before the puncture and before the insertion of the tracheal cannula. Visualization of the tracheal landmarks was rated as 'very good' or 'good' in all but one case. Monitoring during the puncture and dilatation was also rated as 'very good' or 'good' in all but one. In the cases that were rated 'difficult', the visualization and monitoring of the posterior wall of the trachea were the main concerns. No changes in the respiratory variables or blood gases occurred between the puncture and the insertion of the tracheal cannula. Percutaneous dilatational tracheostomy with optical guidance from a tube-mounted camera is feasible. Further studies comparing the camera tube with bronchoscopy as the standard approach should be performed. © 2017 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  9. Balancing Bacteria-Osteoblast Competition through Selective Physical Puncture and Biofunctionalization of ZnO/Polydopamine/Arginine-Glycine-Aspartic Acid-Cysteine Nanorods.

    PubMed

    Li, Jun; Tan, Lei; Liu, Xiangmei; Cui, Zhenduo; Yang, Xianjin; Yeung, Kelvin Wai Kwok; Chu, Paul K; Wu, Shuilin

    2017-11-28

    Bacterial infection and lack of bone tissue integration are two major concerns of orthopedic implants. In addition, osteoinductivity often decreases and toxicity may arise when antibacterial agents are introduced to increase the antibacterial ability. Here hybrid ZnO/polydopamine (PDA)/arginine-glycine-aspartic acid-cysteine (RGDC) nanorod (NR) arrays are designed and prepared on titanium (Ti) implants to not only enhance the osteoinductivity but also effectively kill bacteria simultaneously, which are ascribed to the selective physical puncture and the biofunctionalization of ZnO/PDA/RGDC nanorods during the competition between bacteria and osteoblasts. That is, owing to the much larger size of osteoblasts than bacteria, the hybrid NRs can puncture bacteria but not damage osteoblasts. Meanwhile, the cytocompatibility can be enhanced through the suppression of both reactive oxygen species and higher Zn 2+ concentration by the covering of PDA and RGDC. The in vitro results confirm the selective puncture of the bacterial membrane and the better osteoinductivity. In vivo tests also show much higher antibacterial efficacy of the hybrid NRs with far less amounts of lobulated neutrophils and adherent bacteria in the surrounding tissues. In addition, the hybrid NRs also accelerate formation of new bone tissues (20.1% higher than pure Ti) and osteointegration between implants and newly formed tissues (32.0% higher than pure Ti) even in the presence of injected bacteria. This work provides a surface strategy for designing implants with desirable ability of osseointegration and infection prevention simultaneously, which will exhibit tremendous clinical potential in orthopedic and dental applications.

  10. Ultrasound-guided injection for MR arthrography of the hip: comparison of two different techniques.

    PubMed

    Kantarci, Fatih; Ozbayrak, Mustafa; Gulsen, Fatih; Gencturk, Mert; Botanlioglu, Huseyin; Mihmanli, Ismail

    2013-01-01

    The purpose of this study was to prospectively evaluate the two different ultrasound-guided injection techniques for MR arthrography of the hip. Fifty-nine consecutive patients (21 men, 38 women) referred for MR arthrographies of the hip were prospectively included in the study. Three patients underwent bilateral MR arthrography. The two injection techniques were quantitatively and qualitatively compared. Quantitative analysis was performed by the comparison of injected contrast material volume into the hip joint. Qualitative analysis was performed with regard to extraarticular leakage of contrast material into the soft tissues. Extraarticular leakage of contrast material was graded as none, minimal, moderate, or severe according to the MR images. Each patient rated discomfort after the procedure using a visual analogue scale (VAS). The injected contrast material volume was less in femoral head puncture technique (mean 8.9 ± 3.4 ml) when compared to femoral neck puncture technique (mean 11.2 ± 2.9 ml) (p < 0.05). The chi-squared test showed significantly more contrast leakage by femoral head puncture technique (p < 0.05). Statistical analysis showed no difference between the head and neck puncture groups in terms of feeling of pain (p = 0.744) or in the body mass index (p = 0.658) of the patients. The femoral neck injection technique provides high intraarticular contrast volume and produces less extraarticular contrast leakage than the femoral head injection technique when US guidance is used for MR arthrography of the hip.

  11. A 2-microm continuous-wave laser system for safe and high-precision dissection during NOTES procedures.

    PubMed

    Dray, Xavier; Donatelli, Gianfranco; Krishnamurty, Devi Mukkai; Dubcenco, Elena; Wroblewski, Ronald J; Assumpcao, Lia; Giday, Samuel A; Buscaglia, Jonathan M; Shin, Eun J; Magno, Priscilla; Pipitone, Laurie J; Marohn, Michael R; Kantsevoy, Sergey V; Kalloo, Anthony N

    2010-09-01

    Lasers 2-microm in wavelength offer efficient tissue cutting with limited thermal damage in biological tissue. To evaluate the dissection capabilities of a 2-microm continuous-wave laser for NOTES procedures. We conducted 18 acute animal experiments. Group 1 (three animals): transcolonic access to the peritoneal cavity (15-W transcolonic laser puncture, balloon dilation over the laser probe). Group 2 (six animals): transcolonic access with needle-knife puncture and balloon dilation. Group 3 (three animals): transgastric access to the peritoneal cavity (similar technique as group 1) followed by laser-assisted dissection of the kidney. In one animal of group 3, a therapeutic target (hematoma) was created by percutaneous puncture of the kidney. Group 4 (six animals): transgastric access (similar to the technique of group 2). Translumenal access to the peritoneal cavity was achieved in 2-3 min in group 1 (significantly shorter than with the needle-knife-assisted technique, 4-5 min, p=0.02) and in 7-10 min in group 3 (compared to 6-17 min in group 4, p=0.88). In group 3, laser dissection of the parietal peritoneum and of perinephric connective tissue allowed access to the retroperitoneum with complete removal of a blood collection in the animal with puncture trauma. Laser dissection demonstrated good maneuverability, clean and rapid cutting, and excellent hemostasis. Peritoneoscopy and necropsy showed no damage of targeted tissue and surrounding organs. The 2-microm continuous-wave laser system showed promising capabilities for highly precise and safe dissection during NOTES procedures.

  12. Evaluation of Standard Loose Plastic Packaging for the Management of Rhyzopertha dominica (F.) (Coleoptera: Bostrichidae) and Tribolium castaneum (Herbst) (Coleoptera: Tenebriondiae)

    PubMed Central

    Hassan, Muhammad Waqar; Gulraize; Ali, Usman; Ur Rehman, Fazal; Najeeb, Hafsa; Sohail, Maryam; Irsa, Bakhtawar; Muzaffar, Zubaria; Chaudhry, Muhammad Shafiq

    2016-01-01

    Three standard foodstuff plastic packaging namely polyethylene (PE), polypropylene (PP), and polyvinylchloride (PVC) were evaluated for management of lesser grain borer Rhyzopertha dominica (F.) (Coleoptera: Bostrichidae) and red flour beetle Tribolium castaneum (Herbst) (Coleoptera: Tenebrionidae). Resistance parameters in packaging were recorded as punctures, holes, penetrations, sealing defects, and invasions with two thicknesses and tested for two lengths of time. Damages like punctures, holes and penetrations by both insects were more in PE packaging however R. dominica made more penetrations in PP than in PE. For both insects sealing defects and invasions were predominant in PVC than in others. Thickness did not affect significantly damage types but significantly more holes and penetrations by R. dominica were in less thickness. Punctures and holes by R. dominica were more after less time period but other damages in packaging were more after more time period. However for T. castaneum all sorts of damages were seen more after more time period. Overall categorization between two insects showed R. dominica made more penetrations and T. castaneum made more invasions compared with their counterparts. Pictures were taken under camera fitted microscope to magnify punctures and holes in different packaging and thicknesses. Insect mortality due to phosphine was more in PP and PE packaging and least in PVC packaging and thickness effect was marginal. T. castaneum mortality was significantly more after 48 h than after 24 h. Damages extent in packaging and fumigation results showed PP to be the best of three packaging materials to manage these insects. PMID:27638958

  13. [Anatomic observation of the prostate for clinical application of local drug injection through the rectum for chronic prostatitis].

    PubMed

    Cheng, Jun-ping; Dai, Jing-xing; Liu, Yong-qian; Hong, Hui-wen; Zhang, Xiu-lian; Zhang, Mei-rong; Ye, Qiu-yue

    2003-06-01

    To provide anatomic evidences for local drug injection through the rectum for treating chronic prostatitis and observe the therapeutic effect of this treatment. Anatomic observation of the median sagittal plane of 16 male pelvic specimens was conducted, with special attention to the structures between the prostate and the rectum. The distance from the posterior wall of the prostate to the anterior wall of the rectum, the scope that allowed the entry of the puncture needle, the appropriate puncture depth, and the distance from the anus to the safe were carefully measured. Analysis of the clinical record was performed in 51 chronic prostatitis cases treated with local injection of prednisolone, antibiotic and lidocaine through the rectum. Only some fat tissues and venous plexus were found between the prostate and the anterior wall of the rectum, and the distance from posterior wall of the prostate to the anterior wall of the rectum averaged 5.773+/-0.710 mm. The scope for possible puncture was 15.408 8+/-1.438 2 mm with a depth of 15.703 1+/-0.944 1 mm. The maximum and minimum distances from the anus to the puncture were 47.594+/-2.432 mm and 35.781+/-1.850 mm, respectively. Among the 51 cases investigated, the total cure rate was 84.31%, and improvement was achieved in 13.73% of the case, with only one case (2%) failed to respond to the treatment. Local drug injection through the rectum can be ideal for the treatment of prostatitis for its safety and effectiveness.

  14. The optical "Veress-needle"--initial puncture with a minioptic.

    PubMed

    Schaller, G; Kuenkel, M; Manegold, B C

    1995-02-01

    Laparoscopic access is a necessary part of minimally invasive surgery. The double blind puncture with Veress-needle and trocar can cause lethal complications such as bowel injury, bleeding and gas-embolisation. Some authors have reported alternative techniques for laparoscopic abdominal access. Because no blind procedure can absolutely prevent injury, permanent visual control of perforated tissue layers as in open surgery should be achieved to prevent possible injury at an early stage. Previously described procedures could not fulfil all requirements to comply with this ideal, i.e. permanent visual control of abdominal wall penetration prior to establishment of pneumoperitoneum and trocar insertion without further possible damage. We designed a 2 mm fibreglass optic 250 mm in length that is inserted into a suitable cannula. Special construction allows rinsing through the cannula to clear the vision and to open spaces in the puncture track by water dissection. After incision of the skin, all layers of the abdominal wall can be visualised, including blood vessels and internal surfaces. Once the abdominal cavity is reached, the needle tip is retracted and a two-step dilation allows the trocar to be introduced via the puncture track. Only then does insufflation begin. The fibreglass optic-equipped safety needle was used for visually controlled access in 184 laparoscopic surgical procedures. After a period of training, all layers of the abdominal wall could be recognised exactly. In two patients with dense adhesions, perforation of the small bowel was diagnosed immediately by endoscopic viewing. The small injury needed no treatment, and the intended procedure was completed laparoscopically.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Dual therapeutic action of antibiotic-loaded nanosheets for the treatment of gastrointestinal tissue defects.

    PubMed

    Fujie, Toshinori; Saito, Akihiro; Kinoshita, Manabu; Miyazaki, Hiromi; Ohtsubo, Shinya; Saitoh, Daizoh; Takeoka, Shinji

    2010-08-01

    An ultra-thin polymer film (nanosheet) composed of polysaccharides (i.e., polysaccharide nanosheet) provides sufficient adhesiveness, flexibility and robustness to act as an effective wound dressing. We have recently demonstrated the sealing effect of a nanosheet on a murine cecal puncture. Nevertheless, a small percentage of bacteria penetrated the nanosheet because of its ultra-thin structure. Here, we have developed an antibiotic-loaded nanosheet to inhibit bacterial penetration and investigated its therapeutic efficacy using a model of a murine cecal puncture. Tetracycline (TC) was sandwiched between a poly(vinylacetate) (PVAc) layer and the polysaccharide nanosheet (named PVAc-TC-nanosheet). Under physiological conditions, TC was released from the nanosheet for 6 h. Microscopic observation between the interface of the PVAc-TC-nanosheet and bacteria demonstrated how its potent anti-microbial effect was achieved. In vivo studies show that overlapping therapy with the PVAc-TC-nanosheet (thickness: 177 nm) significantly increases mouse survival rate after cecal puncture as well as suppressing an increase in the intraperitoneal bacterial count and leukocyte count. 2010 Elsevier Ltd. All rights reserved.

  16. Does Atraucan cause more postdural puncture backache?

    PubMed

    Abdullayev, Ruslan; Küçükebe, Omer Burak; Çelik, Bülent; Kirman, Nihal; Hatipoğlu, Hamit Sinan; Akaltun Hatipoğlu, Filiz

    2015-01-01

    Postdural puncture backache (PDPB) is the most frequent complaint after spinal anesthesia. In the literature its importance is generally overshadowed by postdural puncture headache. We studied two different kinds of spinal anesthesia needles to compare their technical handling capacities and incidences of PDPB. Data of 256 pregnant female patients undergoing cesarean delivery under spinal anesthesia were collected for the study. Patients were divided into two groups as Group A (n = 109) and Group Q (n = 147) according to the spinal needle used for spinal anesthesia (i.e. 26-gauge atraumatic and 26-gauge Quincke needles, respectively). Backache incidences during a 1-week period postoperatively and handling characteristics of the needles were noted. Spinal anesthesia was successfully performed at one attempt in 92.7% and 86.4% of patients in Groups A and Q, respectively. PDPB was encountered in 62.4% and 44.2% of patients in Groups A and Q, respectively, and the difference was statistically significant (P = 0.037). Both 26-gauge Atraucan and Quincke needles have excellent handling characteristics. PDPB seems to be less common with the 26-gauge Quincke needle than with the Atraucan needle.

  17. Preoperative Direct Puncture Embolization of Advanced Juvenile Nasopharyngeal Angiofibroma in Combination with Transarterial Embolization: An Analysis of 22 Consecutive Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lv Mingming, E-mail: lvmingming001@163.com; Fan, Xin-dong, E-mail: fanxindong@yahoo.com.cn; Su Lixin, E-mail: sulixin1975@126.com

    2013-02-15

    ObjectiveThis study was designed to evaluate the clinical application of preoperative auxiliary embolization for juvenile nasopharyngeal angiofibroma (JNA) by direct puncture embolization (DPE) of the tumor in combination with transarterial embolization (TAE). The study included 22 patients. An 18-gauge needle was used to puncture directly into the tumor, and 20-25 % N-butyl cyanoacrylate was injected under the guidance of fluoroscopy after confirming the placement of the needle into the JNA and no leaking into the surrounding tissue. Tumors were obstructed later via TAE. The supplying arteries of JNA were from branches of the internal carotid and external carotid arteries. Controlmore » angiography showed the obliteration of contrast stain in the entire tumor mass and the distal supplying arteries disappeared after DPE in combination with TAE. Surgical resection was performed within 4 days after embolization and none of the patients required blood transfusion. The use of DPE in combination with TAE was a safe, feasible, and efficacious method. It can devascularize effectively the JNAs and reduce intraoperative bleeding when JNAs are extirpated.« less

  18. Epidural space identification: a meta-analysis of complications after air versus liquid as the medium for loss of resistance.

    PubMed

    Schier, Robert; Guerra, Diana; Aguilar, Jorge; Pratt, Gregory F; Hernandez, Mike; Boddu, Krishna; Riedel, Bernhard

    2009-12-01

    The best method for identifying the epidural space for neuraxial blocks is controversial. We conducted this meta-analysis to test the hypothesis that loss of resistance with liquid reduces complications with epidural placement. The MEDLINE, EMBASE, and Cochrane databases were searched for prospective, randomized studies comparing air versus liquid as the medium for loss of resistance during epidural space identification in adults. Data were abstracted from 5 studies (4 obstetric and 1 nonobstetric) (n = 4422 patients) that met inclusion criteria and analyzed for the following 6 outcomes: difficult catheter insertion, paresthesia, intravascular catheter insertion, accidental dural puncture, postdural puncture headache, and partial block. The overall risk differences for adverse outcome between the different mediums were not statistically different for the obstetric population. A small, but statistically significant, risk difference for postdural puncture headache was observed when fluid was used during epidural placement for chronic pain management. Larger studies that overcome limitations of heterogeneity across studies and a relatively infrequent occurrence of complications are required to determine the optimal medium for loss of resistance during epidural block.

  19. Regenerative responses after mild heart injuries for cardiomyocyte proliferation in zebrafish

    PubMed Central

    Itou, Junji; Akiyama, Ryutaro; Pehoski, Steve; Yu, Xiaodan; Kawakami, Hiroko; Kawakami, Yasuhiko

    2014-01-01

    Background The zebrafish heart regenerates after various severe injuries. Common processes of heart regeneration are cardiomyocyte proliferation, activation of epicardial tissue and neovascularization. In order to further characterize heart regeneration processes, we introduced milder injuries and compared responses to those induced by ventricular apex resection, a widely used injury method. We used scratching of the ventricular surface and puncturing of the ventricle with a fine tungsten needle as injury inducing techniques. Results Scratching the ventricular surface induced subtle cardiomyocyte proliferation and responses of the epicardium. Endothelial cell accumulation was limited to the surface of the heart. Ventricular puncture induced cardiomyocyte proliferation, endocardial and epicardial activation and neo-vascularization, similar to the resection method. However, the degree of the responses was milder, correlating with milder injury. Sham operation induced epicardial aldh1a2 expression but not tbx18 and WT1. Conclusions Puncturing the ventricle induces responses equivalent to resection at milder degrees in a shorter time frame and would be used as simple injury model. Scratching the ventricle did not induce heart regeneration and would be used for studying wound responses to epicardium. PMID:25074230

  20. [Disposable nursing applicator-pocket of indwelling central venous catheter].

    PubMed

    Wei, Congli; Ma, Chunyuan

    2017-11-01

    Catheter related infection is the most common complication of central venous catheter, which pathogen mainly originate from the pipe joint and the skin around puncture site. How to prevent catheter infection is an important issue in clinical nursing. The utility model disclosed a "disposable nursing applicator-pocket of indwelling central venous catheter", which is mainly used for the fixation and the protection. The main structure consists of two parts, one is medical applicator to protect the skin around puncture site, and the other is gauze pocket to protect the catheter external connector. When in use, the catheter connector is fitted into the pocket, and then the applicator is applied to cover the puncture point of the skin. Integrated design of medical applicator and gauze pocket was designed to realize double functions of fixation and protection. The disposable nursing applicator-pocket is made of medical absorbent gauze (outer layer) and non-woven fabric (inner layer), which has the characteristics of comfortable, breathable, dust filtered, bacteria filtered, waterproof, antiperspirant and anti-pollution. The utility model has the advantages of simple structure, low cost, simple operation, effective protection, easy realization and popularization.

  1. Vaccine vial stopper performance for fractional dose delivery of vaccines

    PubMed Central

    Jarrahian, Courtney; Myers, Daniel; Creelman, Ben; Saxon, Eugene; Zehrung, Darin

    2017-01-01

    ABSTRACT Shortages of vaccines such as inactivated poliovirus and yellow fever vaccines have been addressed by administering reduced—or fractional—doses, as recommended by the World Health Organization Strategic Advisory Group of Experts on Immunization, to expand population coverage in countries at risk. We evaluated 3 kinds of vaccine vial stoppers to assess their performance after increased piercing from repeated withdrawal of doses needed when using fractional doses (0.1 mL) from presentations intended for full-dose (0.5 mL) delivery. Self-sealing capacity and fragmentation of the stopper were assessed via modified versions of international standard protocols. All stoppers maintained self-sealing capacity after 100 punctures. The damage to stoppers measured as the fragmentation rate was within the target of ≤ 10% of punctures resulting in a fragment after as many as 50 punctures. We concluded that stopper failure is not likely to be a concern if existing vaccine vials containing up to 10 regular doses are used up to 50 times for fractional dose delivery. PMID:28463054

  2. Music and 25% glucose pain relief for the premature infant: a randomized clinical trial.

    PubMed

    Cardoso, Maria Vera Lúcia Moreira Leitão; Farias, Leiliane Martins; de Melo, Gleicia Martins

    2014-10-01

    To analyze the total Premature Infant Pain Profile scores of premature infants undergoing arterial puncture during music and 25% glucose interventions, and to assess their association with neonatal and therapeutic variables. A randomized clinical trial with 80 premature infants; 24 in the Experimental Group 1 (music), 33 in the Experimental Group 2 (music and 25% glucose), 23 in the Positive Control Group (25% glucose). All premature infants were videotaped and a lullaby was played for ten minutes before puncture in Experimental Groups 1 and 2; 25% glucose administered in Experimental Group 2 and the Positive Control Group two minutes before puncture. 60.0% of premature infants had moderate or maximum pain; pain scores and intervention groups were not statistically significant. Statistically significant variables: Experimental Group 1: head and chest circumference, Apgar scores, corrected gestational age; Experimental Group 2: chest circumference, Apgar scores, oxygen therapy; Positive Control group: birth weight, head circumference. Neonatal variables are associated with pain in premature infants. Brazilian Registry of Clinical Trials: UTN: U1111-1123-4821.

  3. Complications after LP related to needle type: pencil-point versus Quincke.

    PubMed

    Aamodt, A; Vedeler, C

    2001-06-01

    We studied the incidence of complications after diagnostic lumbar puncture (LP) related to needle type. A 5 months' observational study of routine diagnostic LP in 83 patients was conducted. Significantly more headache was observed after LP using thicker cutting needles (20G Quincke) compared with thinner cutting or non-cutting needles (22G Quincke or pencil-point). No significant difference in complications after LP was found between the 22G Quincke and pencil-point needles. The size of the needle and not the needle shape seems to be the main determinant for post-dural puncture headache (PDPH).

  4. Design of ACM system based on non-greedy punctured LDPC codes

    NASA Astrophysics Data System (ADS)

    Lu, Zijun; Jiang, Zihong; Zhou, Lin; He, Yucheng

    2017-08-01

    In this paper, an adaptive coded modulation (ACM) scheme based on rate-compatible LDPC (RC-LDPC) codes was designed. The RC-LDPC codes were constructed by a non-greedy puncturing method which showed good performance in high code rate region. Moreover, the incremental redundancy scheme of LDPC-based ACM system over AWGN channel was proposed. By this scheme, code rates vary from 2/3 to 5/6 and the complication of the ACM system is lowered. Simulations show that more and more obvious coding gain can be obtained by the proposed ACM system with higher throughput.

  5. Active extravasation of gadolinium-based contrast agent into the subdural space following lumbar puncture.

    PubMed

    Kothari, Pranay D; Hanser, Evelyn M; Wang, Harrison; Farid, Nikdokht

    2016-01-01

    A 38year-old male presented with cauda equina syndrome following multiple lumbar puncture attempts. Lumbar spine magnetic resonance imaging (MRI) showed a subdural hematoma and an area of apparent contrast enhancement in the spinal canal on sagittal post-contrast images. Axial post-contrast images obtained seven minutes later demonstrated an increase in size and change in shape of the region of apparent contrast enhancement, indicating active extravasation of the contrast agent. This is the first reported case of active extravasation of gadolinium-based contrast agent in the spine. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Crossed-swords, capsule-pinch technique for capsulotomy in pediatric and/or loose lens cataract extraction.

    PubMed

    Snyder, Michael E; Lindsell, Luke B

    2010-02-01

    Puncturing the anterior capsule in a patient with a very soft lens, an elastic capsule, and/or deficient zonular countertraction can be challenging even with a sharp needle or blade. The crossed-swords, capsule-pinch technique capitalizes on opposing forces from 2 needles directed toward each other with a "pinch" of the capsule between their tips. This affords a controlled and facile puncture of the capsule without creating stress on the zonules or anteroposterior displacement of the lens. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Between-cycle laser system for depressurization and resealing of modified design nuclear fuel assemblies

    DOEpatents

    Bradley, John G.

    1982-01-01

    A laser beam is used to puncture fuel cladding for release of contained pressurized fission gas from plenum sections or irradiated fuel pins. Exhausted fission gases are collected and trapped for safe disposal. The laser beam, adjusted to welding mode, is subsequently used to reseal the puncture holes. The fuel assembly is returned to additional irradiation or, if at end of reactivity lifetime, is routed to reprocess. The fuel assembly design provides graded cladding lengths, by rows or arrays, such that the cladding of each component fuel element of the assembly is accessible to laser beam reception.

  8. N=2 gauge theories and degenerate fields of Toda theory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kanno, Shoichi; Matsuo, Yutaka; Shiba, Shotaro

    We discuss the correspondence between degenerate fields of the W{sub N} algebra and punctures of Gaiotto's description of the Seiberg-Witten curve of N=2 superconformal gauge theories. Namely, we find that the type of degenerate fields of the W{sub N} algebra, with null states at level one, is classified by Young diagrams with N boxes, and that the singular behavior of the Seiberg-Witten curve near the puncture agrees with that of W{sub N} generators. We also find how to translate mass parameters of the gauge theory to the momenta of the Toda theory.

  9. A navigation system for percutaneous needle interventions based on PET/CT images: design, workflow and error analysis of soft tissue and bone punctures.

    PubMed

    Oliveira-Santos, Thiago; Klaeser, Bernd; Weitzel, Thilo; Krause, Thomas; Nolte, Lutz-Peter; Peterhans, Matthias; Weber, Stefan

    2011-01-01

    Percutaneous needle intervention based on PET/CT images is effective, but exposes the patient to unnecessary radiation due to the increased number of CT scans required. Computer assisted intervention can reduce the number of scans, but requires handling, matching and visualization of two different datasets. While one dataset is used for target definition according to metabolism, the other is used for instrument guidance according to anatomical structures. No navigation systems capable of handling such data and performing PET/CT image-based procedures while following clinically approved protocols for oncologic percutaneous interventions are available. The need for such systems is emphasized in scenarios where the target can be located in different types of tissue such as bone and soft tissue. These two tissues require different clinical protocols for puncturing and may therefore give rise to different problems during the navigated intervention. Studies comparing the performance of navigated needle interventions targeting lesions located in these two types of tissue are not often found in the literature. Hence, this paper presents an optical navigation system for percutaneous needle interventions based on PET/CT images. The system provides viewers for guiding the physician to the target with real-time visualization of PET/CT datasets, and is able to handle targets located in both bone and soft tissue. The navigation system and the required clinical workflow were designed taking into consideration clinical protocols and requirements, and the system is thus operable by a single person, even during transition to the sterile phase. Both the system and the workflow were evaluated in an initial set of experiments simulating 41 lesions (23 located in bone tissue and 18 in soft tissue) in swine cadavers. We also measured and decomposed the overall system error into distinct error sources, which allowed for the identification of particularities involved in the process as well as highlighting the differences between bone and soft tissue punctures. An overall average error of 4.23 mm and 3.07 mm for bone and soft tissue punctures, respectively, demonstrated the feasibility of using this system for such interventions. The proposed system workflow was shown to be effective in separating the preparation from the sterile phase, as well as in keeping the system manageable by a single operator. Among the distinct sources of error, the user error based on the system accuracy (defined as the distance from the planned target to the actual needle tip) appeared to be the most significant. Bone punctures showed higher user error, whereas soft tissue punctures showed higher tissue deformation error.

  10. Percutaneous nephrolithotomy of bilateral staghorn renal calculi in pediatric patients: 12 years experience in a tertiary care centre.

    PubMed

    Purkait, Bimalesh; Kumar, Manoj; Sokhal, Ashok Kumar; Bansal, Ankur; Sankhwar, Satya Narayan; Gupta, Ashok Kumar

    2017-08-01

    To assess the outcomes of percutaneous nephrolithotomy (PCNL) in bilateral staghorn calculi in pediatric patients, we have performed a retrospective analysis. Staghorn calculus is defined as stone that fills a greater part of the pelvic-caliceal system. Still, in developing countries, patients may present with staghorn calculus. PCNL is the preferred treatment modality for staghorn calculus both in adult and children. Our study included fifty-one pediatric patients (<15 years) of bilateral staghorn calculi from 2004 to 2015. Staged PCNL was done after 2-3 days if needed and opposite side PCNL was performed after 10-14 days. Fifty-one patients with bilateral staghorn renal calculi underwent PCNL. The mean age of the study group was 10.25 ± 2.13 (range 3-15). Mean stone burden was 778.3 + 613.4 (range 231-3850 mm 2 ). Forty-five patients underwent single puncture, twenty-two patients underwent double punctures whereas six patients underwent triple punctures during first session PCNL procedure. Most common puncture location was through the superior calyx (58.82 %). The mean operating time was 77.25 + 30.21 (range 58-145). After the first session PCNL, the success rate was 76.47 %. Thirteen patients (17 renal units) underwent relook PCNL and seven patients underwent ESWL. Overall complication noted in twenty-four (47.05 %) cases. Most of the complications were minor grade. Percutaneous nephrolithotomy for staghorn calculus in children needs expertise. PCNL in B/L staghorn renal calculus in children is safe and effective. B/L staghorn renal calculi with compromised renal function have higher chance of complications including bleeding.

  11. Mobile Interventional Stroke Teams Lead to Faster Treatment Times for Thrombectomy in Large Vessel Occlusion.

    PubMed

    Wei, Daniel; Oxley, Thomas J; Nistal, Dominic A; Mascitelli, Justin R; Wilson, Natalie; Stein, Laura; Liang, John; Turkheimer, Lena M; Morey, Jacob R; Schwegel, Claire; Awad, Ahmed J; Shoirah, Hazem; Kellner, Christopher P; De Leacy, Reade A; Mayer, Stephan A; Tuhrim, Stanley; Paramasivam, Srinivasan; Mocco, J; Fifi, Johanna T

    2017-12-01

    Endovascular recanalization treatment for acute ischemic stroke is a complex, time-sensitive intervention. Trip-and-treat is an interhospital service delivery model that has not previously been evaluated in the literature and consists of a shared mobile interventional stroke team that travels to primary stroke centers to provide on-site interventional capability. We compared treatment times between the trip-and-treat model and the traditional drip-and-ship model. We performed a retrospective analysis on 86 consecutive eligible patients with acute ischemic stroke secondary to large vessel occlusion who received endovascular treatment at 4 hospitals in Manhattan. Patients were divided into 2 cohorts: trip-and-treat (n=39) and drip-and-ship (n=47). The primary outcome was initial door-to-puncture time, defined as the time between arrival at any hospital and arterial puncture. We also recorded and analyzed the times of last known well, IV-tPA (intravenous tissue-type plasminogen activator) administration, transfer, and reperfusion. Mean initial door-to-puncture time was 143 minutes for trip-and-treat and 222 minutes for drip-and-ship ( P <0.0001). Although there was a trend in longer puncture-to-recanalization times for trip-and-treat ( P =0.0887), initial door-to-recanalization was nonetheless 79 minutes faster for trip-and-treat ( P <0.0001). There was a trend in improved admission-to-discharge change in National Institutes of Health Stroke Scale for trip-and-treat compared with drip-and-ship ( P =0.0704). Compared with drip-and-ship, the trip-and-treat model demonstrated shorter treatment times for endovascular therapy in our series. The trip-and-treat model offers a valid alternative to current interhospital stroke transfers in urban environments. © 2017 American Heart Association, Inc.

  12. Comparison of 27-gauge (0.41-mm) Whitacre and Quincke spinal needles with respect to post-dural puncture headache and non-dural puncture headache.

    PubMed

    Santanen, U; Rautoma, P; Luurila, H; Erkola, O; Pere, P

    2004-04-01

    The incidence of headache after spinal anaesthesia has varied greatly between studies. We compared the incidence of postoperative headache in general and postdural puncture headache (PDPH) when using 27-gauge (G) (outer diameter 0.41 mm) Quincke and Whitacre spinal needles in ambulatory surgery performed under spinal anaesthesia. In a prospective, randomized study, 676 ASA physical status I-II day-case outpatients were given a spinal anaesthetic through either a 27-G (0.41 mm) Quincke or a 27-G (0.41 mm) Whitacre spinal needle. The incidence of any type of postoperative headache was assessed and the type of headache defined using a standardized questionnaire including PDPH criteria. The severity of the headache was defined using a 100-mm visual analogue scale. For the final analysis, 529 patients were available (259 patients in the Quincke group and 270 patients in the Whitacre group). The overall incidence of postoperative headache was 20.0%, but the incidence of true PDPH was very low (1.51%). The incidence of PDPH in the Quincke group was 2.70%, while in the Whitacre group it was only 0.37% (P < 0.05). The overall incidence of non-dural puncture headache was 18.5% and did not differ between the study groups. True PDPH seldom occurs when a 27-G (0.41 mm) spinal needle is used, although postoperatively a non-specific headache is common. Using the 27-G (0.41 mm) Whitacre spinal needle further reduced the incidence of PDPH. Thus, we recommend routine use of the 27-G (0.41 mm) Whitacre spinal needle when performing spinal anaesthesia.

  13. The effects of needle deformation during lumbar puncture

    PubMed Central

    Özdemir, Hasan Hüseyin; Demir, Caner F.; Varol, Sefer; Arslan, Demet; Yıldız, Mustafa; Akil, Eşref

    2015-01-01

    Objective: The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP). Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. Materials and Methods: The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. Results: A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1%) of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3%) of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%). Forty-seven (41.5%) patients experienced post lumbar puncture headache (PLPH) and 13 (11.5%) patients experienced intracranial hypotension (IH). No statistically significant correlation between the degree of deflection and headache was found (P > 0.05). Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Conclusion: Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH. PMID:25883480

  14. Puncture point-traction method: A novel method applied for right internal jugular vein catheterization

    PubMed Central

    WU, TIANLIANG; ZANG, HONGCHENG

    2016-01-01

    The ultrasound probe and advancement of the needle during real-time ultrasound-assisted guidance of catheterization of the right internal jugular vein (RIJV) tend to collapse the vein, which reduces the success rate of the procedure. We have developed a novel puncture point-traction method (PPTM) to facilitate RIJV cannulation. The present study examined whether this method facilitated the performance of RIJV catheterization in anesthetized patients. In this study, 120 patients were randomly assigned to a group in which PPTM was performed (PPTM group, n=60) or a group in which it was not performed (non-PPTM group, n=60). One patient was excluded because of internal carotid artery puncture and 119 patients remained for analysis. The cross-sectional area (CSA), anteroposterior diameter (AD) and transverse diameter (TD) of the RIJV at the cricoid cartilage level following the induction of anesthesia and during catheterization were measured, and the number with obvious loss of resistance (NOLR), the number with easy aspiration of blood into syringe (NEABS) during advancement of the needle, and the number of first-pass punctures (NFPP) during catheterization were determined. In the non-PPTM group, the CSA was smaller during catheterization compared with that following the induction of anesthesia (P<0.01). In the PPTM group compared with the non-PPTM group during catheterization, the CSA was larger (P<0.01) and the AD (P<0.01) and TD (P<0.05) were wider; NOLR (P<0.01), NEABS (P<0.01) and NFPP (P<0.01) increased significantly. The findings from this study confirmed that the PPTM facilitated catheterization of the RIJV and improved the success rate of RIJV catheterization in anesthetized patients in the supine position. PMID:27347054

  15. Chest Seal Placement for Penetrating Chest Wounds by Prehospital Ground Forces in Afghanistan.

    PubMed

    Schauer, Steven G; April, Michael D; Naylor, Jason F; Simon, Erica M; Fisher, Andrew D; Cunningham, Cord W; Morissette, Daniel M; Fernandez, Jessie Renee D; Ryan, Kathy L

    Thoracic trauma represents 5% of all battlefield injuries. Communicating pneumothoraces resulting in tension physiology remain an important etiology of prehospital mortality. In addressing penetrating chest trauma, current Tactical Combat Casualty Care (TCCC) guidelines advocate the immediate placement of a vented chest seal device. Although the Committee on TCCC (CoTCCC) has approved numerous chest seal devices for battlefield use, few data exist regarding their use in a combat zone setting. To evaluate adherence to TCCC guidelines for chest seal placement among personnel deployed to Afghanistan. We obtained data from the Prehospital Trauma Registry (PHTR). Joint Trauma System personnel linked patients to the Department of Defense Trauma Registry, when available, for outcome data upon reaching a fixed facility. In the PHTR, we identified 62 patients with documented gunshot wound (GSW) or puncture wound trauma to the chest. The majority (74.2%; n = 46) of these were due to GSW, with the remainder either explosive-based puncture wounds (22.6%; n = 14) or a combination of GSW and explosive (3.2%; n = 2). Of the 62 casualties with documented GSW or puncture wounds, 46 (74.2%) underwent chest seal placement. Higher proportions of patients with medical officers in their chain of care underwent chest seal placement than those that did not (63.0% versus 37.0%). The majority of chest seals placed were not vented. Of patients with a GSW or puncture wound to the chest, 74.2% underwent chest seal placement. Most of the chest seals placed were not vented in accordance with guidelines, despite the guideline update midway through the study period. These data suggest the need to improve predeployment training on TCCC guidelines and matching of the Army logistical supply chain to the devices recommended by the CoTCCC. 2017.

  16. Onyx injection by direct puncture for the treatment of hypervascular spinal metastases close to the anterior spinal artery: initial experience.

    PubMed

    Clarençon, Frédéric; Di Maria, Federico; Cormier, Evelyne; Sourour, Nader-Antoine; Enkaoua, Eric; Sailhan, Frédéric; Iosif, Christina; Le Jean, Lise; Chiras, Jacques

    2013-06-01

    Presurgical devascularization of hypervascular spinal metastases has been shown to be effective in preventing major blood loss during open surgery. Most often, embolization can be performed using polyvinyl alcohol (PVA) microparticles. However, in some cases, the close relationship between the feeders of the metastases and the feeders of the anterior spinal artery (ASA) poses a risk of spinal cord ischemia when PVA microparticle embolization is performed. The authors present their early experience in the treatment of spinal metastases close to the ASA; in 2 cases they injected Onyx-18, by direct puncture, into hypervascular posterior arch spinal metastases situated close to the ASA. Two women, one 36 and the other 55 years of age, who presented with spinal lesions (at the posterior arch of C-4 and T-6, respectively) from thyroid and a kidney tumors, were sent to the authors' department to undergo presurgical embolization. After having performed a complete spinal digital subtraction angiography study, a regular angiography catheter was positioned at the ostium of the artery that mainly supplied the lesion. Then, with the patient in the left lateral decubitus position, direct puncture with 18-gauge needles of the lesion was performed using roadmap guidance. Onyx-18 was injected through the needles under biplanar fluoroscopy. Satisfactory devascularization of the lesions was obtained; the ASA remained patent in both cases. The metastases were surgically removed in both cases within the 48 hours after the embolization and major blood loss did not occur. Presurgical devascularization of hypervascular spinal metastases close the ASA by direct puncture with Onyx-18 seems to be an effective technique and appears to be safe in terms of the preserving the ASA's patency.

  17. Toward dynamic lumbar punctures guidance based on single element synthetic tracked aperture ultrasound imaging

    NASA Astrophysics Data System (ADS)

    Zhang, Haichong K.; Lin, Melissa; Kim, Younsu; Paredes, Mateo; Kannan, Karun; Patel, Nisu; Moghekar, Abhay; Durr, Nicholas J.; Boctor, Emad M.

    2017-03-01

    Lumbar punctures (LPs) are interventional procedures used to collect cerebrospinal fluid (CSF), a bodily fluid needed to diagnose central nervous system disorders. Most lumbar punctures are performed blindly without imaging guidance. Because the target window is small, physicians can only accurately palpate the appropriate space about 30% of the time and perform a successful procedure after an average of three attempts. Although various forms of imaging based guidance systems have been developed to aid in this procedure, these systems complicate the procedure by including independent image modalities and requiring image-to-needle registration to guide the needle insertion. Here, we propose a simple and direct needle insertion platform utilizing a single ultrasound element within the needle through dynamic sensing and imaging. The needle-shaped ultrasound transducer can not only sense the distance between the tip and a potential obstacle such as bone, but also visually locate structures by combining transducer location tracking and back projection based tracked synthetic aperture beam-forming algorithm. The concept of the system was validated through simulation first, which revealed the tolerance to realistic error. Then, the initial prototype of the single element transducer was built into a 14G needle, and was mounted on a holster equipped with a rotation tracking encoder. We experimentally evaluated the system using a metal wire phantom mimicking high reflection bone structures and an actual spine bone phantom with both the controlled motion and freehand scanning. An ultrasound image corresponding to the model phantom structure was reconstructed using the beam-forming algorithm, and the resolution was improved compared to without beam-forming. These results demonstrated the proposed system has the potential to be used as an ultrasound imaging system for lumbar puncture procedures.

  18. Effects of anesthesia with halothane and methoxyflurane on plasma corticosterone concentration in rats at rest and after exercise.

    PubMed

    Carlberg, K A; Gwosdow, A R; Alvin, B L

    1995-10-01

    To determine whether halothane and methoxyflurane are suitable anesthetics for cardiac puncture in studies of plasma corticosterone concentration in rats, four experiments were done. Blood samples were taken immediately after rats became anesthetized with halothane or methoxyflurane. Decapitation without anesthesia was used to determine baseline corticosterone concentration. Another group of rats was anesthetized with ether as a positive control (known to stimulate corticosterone secretion). Corticosterone values in halothane- and methoxyflurane-treated rats were not significantly different from those measured after decapitation. Corticosterone concentration in halothane-treated rats was significantly lower than that in either methoxyflurane- or ether-treated rats. Cardiac puncture was done after 3 min of exposure to each of the three anesthetics. The results indicated that there were no differences in corticosterone values among the three anesthetics, suggesting that corticosterone concentration was lower immediately after halothane was used as the anesthetic, because halothane induced anesthesia in less time than that required for activation of adrenocortical secretion. To determine whether there was a difference among anesthetics in stimulating corticosterone secretion when anesthesia was maintained for a period before blood sample collection, cardiac puncture was done after 15 min of exposure to each of the three anesthetics. Corticosterone values were similar, suggesting that any of the three anesthetics was acceptable in this situation. To determine whether halothane or methoxyflurane affected exercise-induced increases in corticosterone values, exercise-trained rats were run for 30 min; then blood samples were collected by cardiac puncture immediately after induction of anesthesia with halothane, methoxyflurane, or ether, or after decapitation without anesthesia. Corticosterone values were not different among the three anesthetics or decapitation.

  19. A comparison of longitudinal and transverse approaches to ultrasound-guided axillary vein cannulation by experienced operators.

    PubMed

    He, Yi-Zhou; Zhong, Ming; Wu, Wei; Song, Jie-Qiong; Zhu, Du-Ming

    2017-04-01

    The axillary vein is an easily accessible vessel that can be used for ultrasound-guided central vascular access and offers an alternative to the internal jugular and subclavian veins. The objective of this study was to identify which transducer orientation, longitudinal or transverse, is better for imaging the axillary vein with ultrasound. We analyzed 236 patients who had undergone central venous cannulation of axillary vein in this retrospective study. Patients were divided into two groups, the longitudinal approach group (n=120) and transverse approach group (n=116). Recorded the one-attempt success rate, operation time, arterial puncture rate and pneumothorax rate. We perform chest radiography to confirm pneumothorax on all patients. We compared the one-attempt success rate, operation time, arterial puncture rate and pneumothorax rate between the two groups. The two groups were comparable with clinical characters of patients. The overall success rates of the longitudinal group and the transverse group were both 100%. The rate of one-attempt success in the longitudinal approach group is higher than the transverse approach group (91.7% vs. 82.8%, P=0.040). The transverse approach group had shorter operation time than the longitudinal group (184.7±8.1 vs. 287.5±19.6 seconds, P=0.000). The two groups had lower postoperative complications. Arterial puncture occurred in 1 of 120 longitudinal and 2 of 116 transverse attempts and this difference was no significant (P=0.541). No pneumothorax occurred in the two groups. The longitudinal approach during ultrasound-guided axillary vein cannulation is associated with greater one-attempt success rate compared with the transverse approach by experienced operators. The transverse approach has shorter operation time. The two groups have lower postoperative complications and are comparable with pneumothorax and arterial puncture.

  20. The effect of self-selected soothing music on fistula puncture-related pain in hemodialysis patients.

    PubMed

    Shabandokht-Zarmi, Hosniyeh; Bagheri-Nesami, Masoumeh; Shorofi, Seyed Afshin; Mousavinasab, Seyed Nouraddin

    2017-11-01

    This study was intended to examine the effect of selective soothing music on fistula puncture-related pain in hemodialysis patients. This is a randomized clinical trial in which 114 participants were selected from two hemodialysis units by means of a non-random, convenience sampling method. The participants were then allocated in three groups of music (N = 38), headphone (N = 38), and control (N = 38). The fistula puncture-related pain was measured 1 min after venipuncture procedure in all three groups. The music group listened to their self-selected and preferred music 6 min before needle insertion into a fistula until the end of procedure. The headphone group wore a headphone alone without listening to music 6 min before needle insertion into a fistula until the end of procedure. The control group did not receive any intervention from the research team during needle insertion into a fistula. The pain intensity was measured immediately after the intervention in all three groups. This study showed a significant difference between the music and control groups, and the music and headphone groups in terms of the mean pain score after the intervention. However, the analysis did not indicate any significant difference between the headphone and control groups with regard to the mean pain score after the intervention. It is concluded that music can be used effectively for pain related to needle insertion into a fistula in hemodialysis patients. Future research should investigate the comparative effects of pharmacological and non-pharmacological interventions on fistula puncture-related pain. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Biocompatible Injectable Hydrogel with Potent Wound Healing and Antibacterial Properties.

    PubMed

    Hoque, Jiaul; Prakash, Relekar G; Paramanandham, Krishnamoorthy; Shome, Bibek R; Haldar, Jayanta

    2017-04-03

    Two component injectable hydrogels that cross-link in situ have been used as noninvasive wound-filling devices, i.e., sealants. These materials carry a variety of functions at the wound sites, such as sealing leaks, ceasing unwanted bleeding, binding tissues together, and assisting in wound healing processes. However, commonly used sealants typically lack antibacterial properties. Since bacterial infection at the wound site is very common, bioadhesive materials with intrinsic antibacterial properties are urgently required. Herein, we report a biocompatible injectable hydrogel with inherent bioadhesive, antibacterial, and hemostatic capabilities suitable for wound sealing applications. The hydrogels were developed in situ from an antibacterial polymer, N-(2-hydroxypropyl)-3-trimethylammonium chitosan chloride (HTCC), and a bioadhesive polymer, polydextran aldehyde. The gels were shown to be active against both Gram-positive and Gram-negative bacteria, including drug-resistant ones such as methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant Enterococcus faecium (VRE), and β-lactam-resistant Klebsiela pneumoniae. Mechanistic studies revealed that the gels killed bacteria upon contact by disrupting the membrane integrity of the pathogen. Importantly, the gels were shown to be efficacious in preventing sepsis in a cecum ligation and puncture (CLP) model in mice. While only 12.5% of animals survived in the case of mice with punctured cecam but with no gel on the punctured area (control), 62.5% mice survived when the adhesive gel was applied to the punctured area. Furthermore, the gels were also shown to be effective in facilitating wound healing in rats and ceasing bleeding from a damaged liver in mice. Notably, the gel showed negligible toxicity toward human red blood cells (only 2-3% hemolysis) and no inflammation to the surrounding tissue upon subcutaneous implantation in mice, thus proving it as a safe and effective antibacterial sealant.

  2. Virtual Simulation in Enhancing Procedural Training for Fluoroscopy-guided Lumbar Puncture: A Pilot Study.

    PubMed

    Ali, Saad; Qandeel, Monther; Ramakrishna, Rishi; Yang, Carina W

    2018-02-01

    Fluoroscopy-guided lumbar puncture (FGLP) is a basic procedural component of radiology residency and neuroradiology fellowship training. Performance of the procedure with limited experience is associated with increased patient discomfort as well as increased radiation dose, puncture attempts, and complication rate. Simulation in health care is a developing field that has potential for enhancing procedural training. We demonstrate the design and utility of a virtual reality simulator for performing FGLP. An FGLP module was developed on an ImmersiveTouch platform, which digitally reproduces the procedural environment with a hologram-like projection. From computed tomography datasets of healthy adult spines, we constructed a 3-D model of the lumbar spine and overlying soft tissues. We assigned different physical characteristics to each tissue type, which the user can experience through haptic feedback while advancing a virtual spinal needle. Virtual fluoroscopy as well as 3-D images can be obtained for procedural planning and guidance. The number of puncture attempts, the distance to the target, the number of fluoroscopic shots, and the approximate radiation dose can be calculated. Preliminary data from users who participated in the simulation were obtained in a postsimulation survey. All users found the simulation to be a realistic replication of the anatomy and procedure and would recommend to a colleague. On a scale of 1-5 (lowest to highest) rating the virtual simulator training overall, the mean score was 4.3 (range 3-5). We describe the design of a virtual reality simulator for performing FGLP and present the initial experience with this new technique. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  3. Feasibility of Retrograde Ureteral Contrast Injection to Guide Ultrasonographic Percutaneous Renal Access in the Nondilated Collecting System.

    PubMed

    Usawachintachit, Manint; Tzou, David T; Mongan, John; Taguchi, Kazumi; Weinstein, Stefanie; Chi, Thomas

    2017-02-01

    Ultrasound-guided percutaneous nephrolithotomy (PCNL) has become increasingly utilized. Patients with nondilated collecting systems represent a challenge: the target calix is often difficult to visualize. Here we report pilot study results for retrograde ultrasound contrast injection to aid in percutaneous renal access during ultrasound-guided PCNL. From April to July 2016, consecutive patients over the age of 18 years with nondilated collecting systems on preoperative imaging who presented for PCNL were enrolled. B-mode ultrasound imaging was compared with contrast-enhanced mode with simultaneous retrograde injection of Optison™ via an ipsilateral ureteral catheter. Five patients (four males and one female) with renal stones underwent PCNL with retrograde ultrasound contrast injection during the study period. Mean body mass index was 28.3 ± 5.6 kg/m 2 and mean stone size was 24.5 ± 12.0 mm. Under B-mode ultrasound, all patients demonstrated nondilated renal collecting systems that appeared as hyperechoic areas, where it was difficult to identify a target calix for puncture. Retrograde contrast injection facilitated delineation of all renal calices initially difficult to visualize under B-mode ultrasound. Renal puncture was then performed effectively in all cases with a mean puncture time of 55.4 ± 44.8 seconds. All PCNL procedures were completed without intraoperative complications and no adverse events related to ultrasound contrast injection occurred. Retrograde ultrasound contrast injection as an aide for renal puncture during PCNL is a feasible technique. By improving visualization of the collecting system, it facilitates needle placement in challenging patients without hydronephrosis. Future larger scale studies comparing its use to standard ultrasound-guided technique will be required to validate this concept.

  4. Effectiveness of Sucrose Used Routinely for Pain Relief and Neonatal Clinical Risk in Preterm Infants: A Nonrandomized Study.

    PubMed

    Valeri, Beatriz Oliveira; Gaspardo, Cláudia Maria; Martinez, Francisco Eulógio; Linhares, Maria Beatriz Martins

    2018-01-03

    Preterm infants (PI) requiring the Neonatal Intensive Care Unit (NICU) are exposed to early repetitive pain/distress. Little is known about how pain relief strategies interact with infants'clinical health status, such as severity of illness with pain responses. This study aimed to examine main and interactive effects of routine sucrose intervention and neonatal clinical risk (NCR) on biobehavioral pain reactivity-recovery in PI during painful blood collection procedures. Very-low birthweight PI (n=104) were assigned to Low and High Clinical Risk Groups, according to the Clinical Risk Index for Babies. Sucrose-Group (SG; n=52) received sucrose solution (25%; 0.5▒mL/Kg) two minutes before the procedures and Control-Group (CG) received standard-care. Biobehavioral pain reactivity-recovery was assessed according to the Neonatal Facial Coding System, Sleep-wake state scale, crying time, and heart rate (HR) at five phases (Baseline, Antisepsis, Puncture, Recovery-Dressing and Recovery-Resting). Repeated measure ANOVA with mixed-design was performed considering pain assessment phases, intervention group, and NCR. Independent of NCR, sucrose presented main effect in decreasing neonates' facial activity pain responses and crying time, during Puncture and Recovery-Resting. Independent of NCR level or routine sucrose intervention, all neonates displayed activated state in Puncture and decreased biobehavioral responses in Recovery-Resting phase. Although no sucrose or NCR effects were observed on physiological reactivity, all neonates exhibited physiological recovery 10 minutes after puncture, reaching the same HR patterns as the Baseline. Independent of NCR level, sucrose intervention for pain relief during acute painful procedures was effective to reduce pain intensity and increase biobehavioral regulation.

  5. Unilateral physiological FDG uptake in teres minor muscle seems well associated with IV tracer injection procedures.

    PubMed

    Nakatani, Koya; Nakamoto, Yuji; Togashi, Kaori

    2015-01-01

    FDG uptake in teres minor (TM) muscle is often physiologically observed. Here we reviewed data of 578 consecutive patients; TM uptake was observed in 138 patients-in 2 of 68 patients who were administered with FDG via a preexisting line and in 136 of 510 after on-site puncture. In 126 patients with TM uptake without unsuccessful on-site puncture, 78% of TM uptake sites were on the ipsilateral side of injection, 8% on the contralateral side, and 14% on both sides; Cohen κ coefficient was 0.815 when confined to unilateral uptake. Therefore, TM uptake seems well associated with tracer injection procedures.

  6. [Complex treatment of patients with cholangiogenic hepatic abscess].

    PubMed

    Nychytaĭlo, M Iu; Skums, A V; Medvets'kyĭ, Ie B; Ohorodnyk, P V; Mashkovs'kyĭ, H Iu; Shkarban, V P; Shkarban, P O; Farzolakh, Mekhraban Jafarlu

    2005-07-01

    Results of treatment of 47 patients with cholangiogenic hepatic abscess were analyzed. Clinical, laboratory and special methods of investigation were applied for diagnosis. The authors consider ultrasound investigation (USI), computer tomography and the abscess puncture under the USI control with subsequent cytological and bacterial control the decisive methods in diagnosis of hepatic abscess. In complex of treatment of patients miniinvasive technologies were applied--the abscess puncture, its cavity drainage under USI control transcutaneus transhepatic cholangiostomy, endoscopic papillosphincterotomy with lithotripsy and nasobiliary drainage, according to indications. Efficacy of the abscess cavity sanation, using miramistinum and decasan, was proved. In general therapy the directed transport of medicines was applied.

  7. [Cranial nerve damage after neuroaxial methods of anesthesia in puerperas].

    PubMed

    Floka, S E; Shifman, E M

    2007-01-01

    The paper describes cranial nerve damage, a rare complication of neuroaxial anesthesia in obstetric care. In the literature, there are summarized data on 17 cases of neurological deficit developing after subarachnoidal or epidural anesthesia in puerperas. The etiological and pathogenetic factors of the above complications may be suggested to be the high disposition of a local anesthetic, arterial hypotension due to neuroaxial anesthetics, the outflow of cerebrospinal fluid after pachymeningeal puncture (including after unintended puncture during epidural anesthesia), and ischemic injury after the blood packing performed to relieve postpuncture headache. Closer consideration of these risk factors seems to reduce the incidence of cranial nerve damage in puerperas.

  8. Echocardiography-guided or "sided" pericardiocentesis.

    PubMed

    Degirmencioglu, Aleks; Karakus, Gultekin; Güvenc, Tolga Sinan; Pinhan, Osman; Sipahi, Ilke; Akyol, Ahmet

    2013-10-01

    Echocardiography-guided pericardiocentesis is the first choice method for relieving cardiac tamponade, but the exact role of the echocardiography at the moment of the puncture is still controversial. In this report, detailed echocardiographic evaluation was performed in 21 consecutive patients with cardiac tamponade just before the pericardiocentesis. Appropriate needle position was determined according to the probe position using imaginary x, y, and z axes. Pericardiocentesis was performed successfully using this technique without simultaneous echocardiography and no complications were observed. We concluded that bedside echocardiography with detailed evaluation of the puncture site and angle is enough for pericardiocentesis instead of real time guiding. © 2013, Wiley Periodicals, Inc.

  9. Laser-heat puncturing as highly effective method of post-tuberculous cystalgia treatment

    NASA Astrophysics Data System (ADS)

    Koultchavenia, Ekaterina V.

    1999-07-01

    The tuberculosis of an urine bladder in men develops is authentic less often, and recovery is authentic more often, than in the women. In 39,1 percent of the women with nephrotuberculosis and urocystis and urocystis tuberculosis a specific cystitides is finished in development of post- tuberculous cystalgia. One of starting mechanism of dysuria after the transferred urocystis tuberculosis in the women in menopause is hormonal insufficiency. The method of laser heat puncturing, developed by us, for the treatment this complication is highly effective, does not require additional introduction of medicines, can be executed as in hospitals, and in our-patient.

  10. Epidural analgesia complicated by dural ectasia in the Marfan syndrome

    PubMed Central

    Gray, Chelsea; Hofkamp, Michael P.; Noonan, Patrick T.; McAllister, Russell K.; Pilkinton, Kimberly A.; Diao, Zhiying

    2016-01-01

    Patients with the Marfan syndrome are considered to be high risk during pregnancy and warrant a complete multidisciplinary evaluation. One goal is to minimize hemodynamic fluctuations during labor since hypertensive episodes may result in aortic dissection or rupture. Although they may prevent these complications, neuraxial techniques may be complicated by dural ectasia. The case of a parturient with the Marfan syndrome and mild dural ectasia is presented. During attempted labor epidural placement, unintentional dural puncture occurred. A spinal catheter was used for adequate labor analgesia, and a resultant postdural puncture headache was alleviated by an epidural blood patch under fluoroscopic guidance. PMID:27695168

  11. Cardioembolic strokes resulting from a self-inflicted needle puncture involving both sides of the heart.

    PubMed

    Tan, Mark Zheng Yi; Brunswicker, Annemarie; Abdelraheem, Shamsaldeen; Sheehan, Alison

    2017-04-01

    Foreign bodies in the heart are rare occurrences with a limited evidence base to guide recommendations on management. We report a case of multiple cardioembolic strokes as a result of a self-inflicted sewing needle puncture from the anterior chest through the right ventricle and interventricular septum with its tip in the left ventricle close to the subvalvular apparatus in a 39-year-old psychiatric patient. We discuss issues surrounding decision making and ongoing care and highlight the importance of further follow-up and reporting of cases to form a robust evidence base to guide future recommendations. © 2017, Wiley Periodicals, Inc.

  12. Post-procedure bleeding in interventional radiology.

    PubMed

    Mayer, J; Tacher, V; Novelli, L; Djabbari, M; You, K; Chiaradia, M; Deux, J-F; Kobeiter, H

    2015-01-01

    Following interventional radiology procedures, bleeding can occur in 0.5 to 4% of the cases. Risk factors are related to the patient, to the procedure, and to the end organ. Bleeding is treated usually by interventional radiologists and consists mainly of embolization. Bleeding complications are preventable: before the procedure by checking hemostasis, during the procedure by ensuring the accurate puncture site (with ultrasound or fluoroscopy guidance) or by treating the puncture path using gelatin sponge, curaspon(®), biological glue or thermocoagulation, and after the procedure by carefully monitoring the patients. Copyright © 2015 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  13. Rate-compatible punctured convolutional codes (RCPC codes) and their applications

    NASA Astrophysics Data System (ADS)

    Hagenauer, Joachim

    1988-04-01

    The concept of punctured convolutional codes is extended by punctuating a low-rate 1/N code periodically with period P to obtain a family of codes with rate P/(P + l), where l can be varied between 1 and (N - 1)P. A rate-compatibility restriction on the puncturing tables ensures that all code bits of high rate codes are used by the lower-rate codes. This allows transmission of incremental redundancy in ARQ/FEC (automatic repeat request/forward error correction) schemes and continuous rate variation to change from low to high error protection within a data frame. Families of RCPC codes with rates between 8/9 and 1/4 are given for memories M from 3 to 6 (8 to 64 trellis states) together with the relevant distance spectra. These codes are almost as good as the best known general convolutional codes of the respective rates. It is shown that the same Viterbi decoder can be used for all RCPC codes of the same M. The application of RCPC codes to hybrid ARQ/FEC schemes is discussed for Gaussian and Rayleigh fading channels using channel-state information to optimize throughput.

  14. Evaluation of 25-gauge Quincke and 24-gauge Gertie Marx needles for spinal anaesthesia for caesarean section.

    PubMed

    Imarengiaye, C O; Edomwonyi, N P

    2002-07-01

    To compare the insertion characteristics and rate of complications between 25-gauge Quincke and 24-gauge Gertie Marx needles. Prospective, randomized study. University of Benin Teaching Hospital; a university-affiliated tertiary centre. Parturients (ASA 1 and 2) scheduled for elective caesarean section. They were randomly assigned to receive spinal anaesthesia with either 25-gauge Quincke needle or 24-gauge Gertie Marx needle. The patients with abnormal spaces, coagulopathy, infection, pre-eclampsia/eclampsia or obesity were excluded. The number of attempts at successful identification of the spinal space, intraoperative complications, incidence of postdural puncture headache (PDPH), non-postdural puncture headache (NPDPH) and backache. Sixty women were studied. The 24-gauge Gertie Marx needle resulted in more successful location of the spinal space on the second attempt (P<0.05). Non-postdural puncture headache was seen in 43% of the study population. PDPH was seen in 10% of the Quincke group and none in the Gertie Marx group. There was no difference in the incidence of backache in both groups. The ease of insertion and low incidence of PDPH with the Gertie Marx needle may encourage trainee anaesthetists to use this needle for caesarean section.

  15. Plasma membrane translocation of a protein needle based on a triple-stranded β-helix motif.

    PubMed

    Sanghamitra, Nusrat J M; Inaba, Hiroshi; Arisaka, Fumio; Ohtan Wang, Dan; Kanamaru, Shuji; Kitagawa, Susumu; Ueno, Takafumi

    2014-10-01

    Plasma membrane translocation is challenging due to the barrier of the cell membrane. Contrary to the synthetic cell-penetrating materials, tailed bacteriophages use cell-puncturing protein needles to puncture the cell membranes as an initial step of the DNA injection process. Cell-puncturing protein needles are thought to remain functional in the native phages. In this paper, we found that a bacteriophage T4 derived protein needle of 16 nm length spontaneously translocates through the living cell membrane. The β-helical protein needle (β-PN) internalizes into human red blood cells that lack endocytic machinery. By comparing the cellular uptake of β-PNs with modified surface charge, it is shown that the uptake efficiency is maximum when it has a negative charge corresponding to a zeta potential value of -16 mV. In HeLa cells, uptake of β-PN incorporates endocytosis independent mechanisms with partial macropinocytosis dependence. The endocytosis dependence of the uptake increases when the surface charges of β-PNs are modified to positive or negative. Thus, these results suggest that natural DNA injecting machinery can serve as an inspiration to design new class of cell-penetrating materials with a tailored mechanism.

  16. Effects caused by the spinal administration of ketamine S (+) 5% with no preservatives, using a single puncture, and located on the spinal cord and meninges in rabbits.

    PubMed

    Lima Filho, José Admirço; Fin, Natalia Castro; Valerini, Felipe Gilberto; Machado, Vania Maria; Marques, Mariangela Ester; Miot, Hélio; Lima, Lais Helena Navarro E; Ganen, Eliana Marisa

    2014-07-01

    To evaluate the effect of ketamine S (+) 5% with no preservatives and administered as a subarachnoid single puncture on the spinal cord and meninges of rabbits. Twenty young adult female rabbits, each weighing 3500-5000 g and having a spine length between 34 and 38 cm, were divided by lot into two groups (G): 0.9% saline in G1 and ketamine S (+) 5% in G2, by volume of 5 μg per cm column (0.18 mL). After intravenous anaesthesia with ketamine and xylazine, the subarachnoid space was punctured at S1-S2 under ultrasound guidance, and a random solution was injected. The animals remained in captivity for 21 days under medical observation and were sacrificed by decapitation. The lumbosacral spinal cord portion was removed for immunohistochemistry to assess the glial fibrillary acidic protein (GFAP), and histology was assessed using hematoxylin and eosin (HE) stain. No histological lesions were found in the nervous tissue (roots and cord) or meninges in either group. The ketamine S (+) 5% unpreserved triggered no neurological or histological lesions in the spinal cord or meninges of rabbits.

  17. Sepsis Reduces Bone Strength Before Morphologic Changes Are Identifiable.

    PubMed

    Puthucheary, Zudin A; Sun, Yao; Zeng, Kaiyang; Vu, Lien Hong; Zhang, Zhi Wei; Lim, Ryan Z L; Chew, Nicholas S Y; Cove, Matthew E

    2017-12-01

    Survivors of critical illness have an increased prevalence of bone fractures. However, early changes in bone strength, and their relationship to structural changes, have not been described. We aimed to characterize early changes in bone functional properties in critical illness and their relationship to changes in bone structure, using a sepsis rodent model. Experimental study. Animal research laboratory. Adult Sprague-Dawley rats. Forty Sprague-Dawley rats were randomized to cecal ligation and puncture or sham surgery. Twenty rodents (10 cecal ligation and puncture, 10 sham) were killed at 24 hours, and 20 more at 96 hours. Femoral bones were harvested for strength testing, microCT imaging, histologic analysis, and multifrequency scanning probe microscopy. Fracture loads at the femoral neck were significantly reduced for cecal ligation and puncture-exposed rodents at 24 hours (83.39 ± 10.1 vs 103.1 ± 17.6 N; p = 0.014) and 96 hours (81.60 ± 14.2 vs 95.66 ± 14.3 N; p = 0.047). Using multifrequency scanning probe microscopy, collagen elastic modulus was lower in cecal ligation and puncture-exposed rats at 24 hours (1.37 ± 0.2 vs 6.13 ± 0.3 GPa; p = 0.001) and 96 hours (5.57 ± 0.5 vs 6.13 ± 0.3 GPa; p = 0.006). Bone mineral elastic modulus was similar at 24 hours but reduced in cecal ligation and puncture-exposed rodents at 96 hours (75.34 ± 13.2 vs 134.4 ± 8.2 GPa; p < 0.001). There were no bone architectural or bone mineral density differences by microCT. Similarly, histologic analysis demonstrated no difference in collagen and elastin staining, and C-X-C chemokine receptor type 4, nuclear factor kappa beta, and tartrate-resistant acid phosphatase immunostaining. In a rodent sepsis model, trabecular bone strength is functionally reduced within 24 hours and is associated with a reduction in collagen and mineral elastic modulus. This is likely to be the result of altered biomechanical properties, rather than increased bone mineral turnover. These data offer both mechanistic insights and may potentially guide development of therapeutic interventions.

  18. Characterising the material properties at the interface between skin and a skin vaccination microprojection device.

    PubMed

    Crichton, Michael L; Archer-Jones, Cameron; Meliga, Stefano; Edwards, Grant; Martin, Darren; Huang, Han; Kendall, Mark A F

    2016-05-01

    The rapid emergence of micro-devices for biomedical applications over the past two decades has introduced new challenges for the materials used in the devices. Devices like microneedles and the Nanopatch, require sufficient strength to puncture skin often with sharp-slender micro-scale profiles, while maintaining mechanical integrity. For these technologies we sought to address two important questions: 1) On the scale at which the device operates, what forces are required to puncture the skin? And 2) What loads can the projections/microneedles withstand prior to failure. First, we used custom fabricated nanoindentation micro-probes to puncture skin at the micrometre scale, and show that puncture forces are ∼0.25-1.75mN for fresh mouse skin, in agreement with finite element simulations for our device. Then, we used two methods to perform strength tests of Nanopatch projections with varied aspect ratios. The first method used a nanoindenter to apply a force directly on the top or on the side of individual silicon projections (110μm in length, 10μm base radius), to measure the force of fracture. Our second method used an Instron to fracture full rows of projections and characterise a range of projection designs (with the method verified against previous nanoindentation experiments). Finally, we used Cryo-Scanning Electron Microscopy to visualise projections in situ in the skin to confirm the behaviour we quantified, qualitatively. Micro-device development has proliferated in the past decade, including devices that interact with tissues for biomedical outcomes. The field of microneedles for vaccine delivery to skin has opened new material challenges both in understanding tissue material properties and device material. In this work we characterise both the biomaterial properties of skin and the material properties of our microprojection vaccine delivery device. This study directly measures the micro-scale puncture properties of skin, whilst demonstrating clearly how these relate to device design. This will be of strong interest to those in the field of biomedical microdevices. This includes work in the field of wearable and semi-implantable devices, which will require clear understanding of tissue behaviour and material characterisation. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  19. Effects of four different positive airway pressures on right internal jugular vein catheterisation.

    PubMed

    Zhou, Qinghe; Xiao, Wangpin; An, Erdan; Zhou, Hongmei; Yan, Min

    2012-05-01

    The right internal jugular vein (RIJV) is often used for central venous catheterisation in patients undergoing major surgery. The efficacy of this route correlates with the diameter of the vein which can be influenced by airway pressure. To investigate four positive airway pressures (PAPs) in mechanically ventilated patients and to determine the most suitable of these for RIJV catheterisation. Prospective, randomised, controlled study. Two Chinese medical centres. Two hundred and forty patients scheduled for gastrointestinal tract surgery under general anaesthesia (male-to-female ratio, 135 : 105; American Society of Anesthesiologists' physical status class, I-III; age range, 19-81 years); patients were excluded from the study if they had a history of haematological disease, external neck injury, RIJV catheterisation, severe cardiovascular disease, RIJV thrombosis, injection-site infection, pneumothorax and pulmonary bulla. They were randomised into four groups of 60, each to undergo RIJV catheterisation at a PAP of 0 (1 cmH2O = 0.098 kPa, group A); 15 (group B); 20 (group C); and 25 cmH2O (group D). Primary outcomes were central venous pressure (CVP) and RIJV cross-sectional area which were measured before and during PAP; the number of catheterisations completed in 30 s; the number of first pass punctures; heart rate and mean arterial pressure which were monitored continuously; and the incidence of complications which included local haematoma, pneumothorax and internal carotid artery (ICA) puncture. Two patients were excluded following ICA puncture, leaving 238 for analysis. In groups C and D, the CVP and the cross-sectional area of RIJV were significantly larger; the number completing catheterisation within 30 s and the number of first pass punctures increased significantly and was comparable between these two groups. Compared with groups A and B, the incidences of hypotension and bradycardia were significantly increased in groups C and D. The incidence of local haematoma was significantly increased in group D compared with other groups. RIJV catheterisation was completed successfully in all but two patients in group A. A PAP of 20 cmH2O seems most suitable for successful RIJV catheterisation in mechanically ventilated patients. It is associated with an increase in cross-sectional RIJV area and CVP, which facilitate cannulation, and results in fewer puncture-related complications. However, meticulous haemodynamic monitoring is needed to avoid hypotension and bradycardia.

  20. Ignition of Fuel Vapors Beneath Titanium Aircraft Skins Exposed to Lightning

    NASA Technical Reports Server (NTRS)

    Kosvic, T. C.; Helgeson, N. L.; Gerstein, M.

    1971-01-01

    Hot-spot and puncture ignition of fuel vapors by simulated lightning discharges was studied experimentally. The influences of skin coating, skin structure, discharge polarity, skin thickness, discharge current level, and current duration were measured and interpreted. Ignition thresholds are reported for titanium alloy constructed as sheets, sheets coated with sealants, and sandwich skins. Results indicated that the ignition threshold charge transfer for coated sheets, honeycomb, and truss skins is respectively about 200%, 400%, 800% that of bare alloy sheet of .102 cm (.040 in.)-thickness. It was found that hot-spot ignition can occur well after termination of the arc, and that sandwich materials allow ignition only if punctured.

  1. Conservative treatment of massive hemothorax in a girl with neuroblastoma.

    PubMed

    Shiokawa, Naohiro; Okamoto, Yasuhiro; Kodama, Yuichi; Nishikawa, Takuro; Tanabe, Takayuki; Mukai, Motoi; Yoshioka, Takako; Kawano, Yoshifumi

    2016-10-01

    We report the case of a 1-year-old girl with stage 4 neuroblastoma who developed massive hemothorax due to tumor invasion before treatment. She presented with tachypnea, worsening anemia, and oxygen desaturation. Hemothorax was diagnosed based on chest radiography, ultrasonography, and diagnostic thoracic puncture results. High neuron-specific enolase, vanillylmandelic acid, and homovanillic acid as well as computed tomography strongly supported a diagnosis of neuroblastoma. Chemotherapy along with intermittent puncture drainage, oxygen, and blood transfusion reduced the accumulated blood, and hemothorax disappeared within 1 week. Thus, it is possible to avoid invasive treatment for massive hemothorax by initiating chemotherapy for chemosensitive solid tumors, including neuroblastoma. © 2016 Japan Pediatric Society.

  2. State of some peripheral organs during laser puncture correction of ovarian functional deficiency

    NASA Astrophysics Data System (ADS)

    Vylegzhanina, T. A.; Kuznetsova, Tatiana I.; Maneeva, O.; Ryzhkovskaya, E. L.; Yemelianova, A.

    2001-01-01

    The findings from studies on structural and functional parameters of the adrenal, thyroid, and pineal glands in conditions of ovarian hypofunction and after its correction by laser puncture are presented. An experimentally induced hypofunction of the ovaries was shown to be accompanied by a decreased hormonal synthesis in the cortical fascicular zone. The epiphysis showed ultra structural signs of increased functional activity. Application of a helium-neon laser to biologically active points of the ovarian reflexogenic zone induced normalization of the ovarian cycle, potentiating of the adrenal functional state, and a decreased thyroid hormone production and abolished the activatory effect of the dark regime on the functional state of the pineal gland.

  3. A new second-puncture probe for CO2 laser laparoscopy.

    PubMed

    Daniell, J F; Herbert, C M

    1985-02-01

    A new second-puncture probe system was designed for aiming and firing the CO2 laser under laparoscopic control. The probe allows simultaneous suction of the smoke from vaporization and insufflation of fresh CO2 for maintenance of an adequate pneumoperitoneum during use. A 200-mm focusing lens attaches the probe to any surgical CO2 laser with an articulated arm. The new probe is 10 cm shorter than standard probes, allowing the application of a wider range of power densities during laser laparoscopy and making surgery easier to perform. Our initial experiences with this new instrument have involved both laboratory animals and patients with endometriosis, adnexal adhesions and distal tubal obstruction.

  4. [Bacterial meningitis in adults in emergency and rescue services].

    PubMed

    Klein, M; Pfister, H-W

    2016-10-01

    The cardinal symptoms of bacterial meningitis are headache, fever, impaired consciousness and nuchal stiffness (meningism); however, the diagnosis of acute bacterial meningitis can only be confirmed or ruled out by investigation of cerebrospinal fluid. The recommended empirical antibiotic regimen for community-acquired acute bacterial meningitis in adults in Germany is a combination of ceftriaxone and ampicillin plus adjuvant dexamethasone. An important influenceable factor for treatment success of acute bacterial meningitis is a rapid induction of antibiotic therapy, which must be initiated directly after lumbar puncture. When this is delayed for any reason, e. g. because of the necessity of cerebral computed tomography imaging before lumbar puncture, antibiotics should be started even before acquisition of cerebrospinal fluid.

  5. Silicon amendment to rice plants impairs sucking behaviors and population growth in the phloem feeder Nilaparvata lugens (Hemiptera: Delphacidae).

    PubMed

    Yang, Lang; Han, Yongqiang; Li, Pei; Wen, Lizhang; Hou, Maolin

    2017-04-24

    The brown planthopper (BPH), Nilaparvata lugens (Stål), is a migratory and destructive sucking insect pest of rice. Silicon (Si) amendment to plants can confer enhanced resistance to herbivores and is emerging as a novel approach for pest management. In the present study, we tested the effects of Si addition at 0.16 (low) and 0.32 (high) g Si/kg soil on sucking behaviors and population growth in BPH. Si amendment increased Si content in rice stems and extended non-probing event and phloem puncture followed by sustained phloem ingestion over that in the no-Si-addition control. High Si addition rate prolonged the stylet pathway and the time needed to reach the first phloem puncture, shortened durations of phloem puncture and phloem ingestion, and decreased the proportion of individuals that produced sustained phloem ingestion. BPH female feeding on and preference for plants with the high Si addition rate were also reduced. As a result, Si application significantly decreased BPH population growth rates while increased population doubling time. These results indicate that Si amendment, especially at the high rate, confers enhanced rice plant resistance to BPH through impairment of BPH feeding. Our results highlight the potential of Si amendment as an alternative for BPH management.

  6. Computer tomography urography assisted real-time ultrasound-guided percutaneous nephrolithotomy on renal calculus.

    PubMed

    Fang, You-Qiang; Wu, Jie-Ying; Li, Teng-Cheng; Zheng, Hao-Feng; Liang, Guan-Can; Chen, Yan-Xiong; Hong, Xiao-Bin; Cai, Wei-Zhong; Zang, Zhi-Jun; Di, Jin-Ming

    2017-06-01

    This study aimed to assess the role of pre-designed route on computer tomography urography (CTU) in the ultrasound-guided percutaneous nephrolithotomy (PCNL) for renal calculus.From August 2013 to May 2016, a total of 100 patients diagnosed with complex renal calculus in our hospital were randomly divided into CTU group and control group (without CTU assistance). CTU was used to design a rational route for puncturing in CTU group. Ultrasound was used in both groups to establish a working trace in the operation areas. Patients' perioperative parameters and postoperative complications were recorded.All operations were successfully performed, without transferring to open surgery. Time of channel establishment in CTU group (6.5 ± 4.3 minutes) was shorter than the control group (10.0 ± 6.7 minutes) (P = .002). In addition, there was shorter operation time, lower rates of blood transfusion, secondary operation, and less establishing channels. The incidence of postoperative complications including residual stones, sepsis, severe hemorrhage, and perirenal hematoma was lower in CTU group than in control group.Pre-designing puncture route on CTU images would improve the puncturing accuracy, lessen establishing channels as well as improve the security in the ultrasound-guided PCNL for complex renal calculus, but at the cost of increased radiation exposure.

  7. The use of Quincke and Whitacre 27-gauge needles in orthopedic patients: incidence of failed spinal anesthesia and postdural puncture headache.

    PubMed

    Lynch, J; Kasper, S M; Strick, K; Topalidis, K; Schaaf, H; Zech, D; Krings-Ernst, I

    1994-07-01

    This study examined the incidence of failed spinal anesthesia and postdural puncture headache using a 27-gauge Whitacre and a 27-gauge Quincke needle in patients undergoing elective inpatient orthopedic procedures. The overall rate of failed spinal anesthesia was 8.5% [95% confidence interval (CI) = 4.6%-12.4%] (n = 17) in the Quincke group (n = 199) and 5.5% [95% CI = 2.3%-8.7%] (n = 11) in the Whitacre group (n = 199). This difference was not statistically significant. The overall incidence of postdural puncture headache (PDPH) was 0.8%; 1.1% [95% CI = 0%-2.4%] (n = 2) in the Quincke group and 0.5% [95% CI = 0%-1.5%] (n = 1) in the Whitacre group. These differences were not statistically significant. All headaches were classified as mild and resolved spontaneously with conservative management. The mean time for withdrawal of the stylet to appearance of cerebrospinal fluid was 10.8 +/- 6.9 s in the Quincke (n = 31) and 10.7 +/- 6.8 s in the Whitacre group (n = 33). These differences were not statistically significant. Our results suggest that both needles are associated with a very low incidence of PDPH and an incidence of failed anesthesia of 5.5%-8.5%.

  8. In-Plane Ultrasound-Guided Knee Injection Through a Lateral Suprapatellar Approach: A Safe Technique.

    PubMed

    Chagas-Neto, Francisco A; Taneja, Atul K; Gregio-Junior, Everaldo; Nogueira-Barbosa, Marcello H

    2017-06-01

    This study aims to describe a technique for in-plane ultrasound-guided knee arthrography through a lateral suprapatellar approach, reporting its accuracy and related complications. A retrospective search was performed for computed tomography and magnetic resonance reports from June 2013 through June 2015. Imaging studies, puncture descriptions, and guided-procedure images were reviewed along with clinical and surgical history. A fellowship-trained musculoskeletal radiologist performed all procedures under sterile technique and ultrasound guidance with the probe in oblique position on the lateral suprapatellar recess after local anesthesia with the patient on dorsal decubitus, hip in neutral rotation, and 30 to 45 degrees of knee flexion. A total of 86 consecutive subjects were evaluated (mean, 55 years). All subjects underwent intra-articular injection of contrast, which was successfully reached in the first attempt in 94.2% of the procedures (81/86), and in the second attempt in 5.8% (5/86) after needle repositioning without a second puncture. There were no postprocedural reports of regional complications at the puncture site, such as significant pain, bleeding, or vascular lesions. Our study demonstrates that in-plane ultrasound-guided injection of the knee in semiflexion approaching the lateral suprapatellar recess is a safe and useful technique to administer intra-articular contrast solution, as an alternative method without radiation exposure.

  9. Low-temperature infiltration identified using infrared thermography in patients with subcutaneous edema revealed ultrasonographically: A case report.

    PubMed

    Oya, Maiko; Takahashi, Toshiaki; Tanabe, Hidenori; Oe, Makoto; Murayama, Ryoko; Yabunaka, Koichi; Matsui, Yuko; Sanada, Hiromi

    Infiltration is a frequent complication of infusion therapy. We previously demonstrated the usefulness of infrared thermography as an objective method of detecting infiltration in healthy people. However, whether thermography can detect infiltration in clinical settings remains unknown. Therefore, we report two cases where thermography was useful in detecting infiltration at puncture sites. In both cases, tissue changes were verified ultrasonographically. The patients were a 56-year-old male with cholangitis and a 76-year-old female with hepatoma. In both cases, infiltration symptoms such as swelling and erythema occurred one day after the insertion of a peripheral intravenous catheter. Thermographic images from both patients revealed low-temperature areas spreading from the puncture sites; however, these changes were not observed in other patients. The temperature difference between the low-temperature areas and their surrounding skin surface exceeded 1.0°C. Concurrently, ultrasound images revealed that tissues surrounding the vein had a cobblestone appearance, indicating edema. In both patients, subcutaneous tissue changes suggested infiltration and both had low-temperature areas spreading from the puncture sites. Thus, subcutaneous edema may indicate infusion leakage, resulting in a decrease in the temperature of the associated skin surface. These cases suggest that infrared thermography is an effective method of objectively and noninvasively detecting infiltration.

  10. A biplanar fluoroscopic approach for the measurement, modeling, and simulation of needle and soft-tissue interaction.

    PubMed

    Hing, James T; Brooks, Ari D; Desai, Jaydev P

    2007-02-01

    A methodology for modeling the needle and soft-tissue interaction during needle insertion is presented. The approach consists of the measurement of needle and tissue motion using a dual C-arm fluoroscopy system. Our dual C-arm fluoroscopy setup allows real time 3-D extraction of the displacement of implanted fiducials in the soft tissue during needle insertion to obtain the necessary parameters for accurate modeling of needle and soft-tissue interactions. The needle and implanted markers in the tissue are tracked during the insertion and withdrawal of the needle at speeds of 1.016 mm/s, 12.7 mm/s and 25.4 mm/s. Both image and force data are utilized to determine important parameters such as the approximate cutting force, puncture force, the local effective modulus (LEM) during puncture, and the relaxation of tissue. We have also validated the LEM computed from our finite element model with arbitrary needle puncture tasks. Based on these measurements, we developed a model for needle insertion and withdrawal that can be used to generate a 1-DOF force versus position profile that can be experienced by a user operating a haptic device. This profile was implemented on a 7-DOf haptic device designed in our laboratory.

  11. Stretch-and-release fabrication, testing and optimization of a flexible ceramic armor inspired from fish scales.

    PubMed

    Martini, Roberto; Barthelat, Francois

    2016-10-13

    Protective systems that are simultaneously hard to puncture and compliant in flexion are desirable, but difficult to achieve because hard materials are usually stiff. However, we can overcome this conflicting design requirement by combining plates of a hard material with a softer substrate, and a strategy which is widely found in natural armors such as fish scales or osteoderms. Man-made segmented armors have a long history, but their systematic implementation in a modern and a protective system is still hampered by a limited understanding of the mechanics and the design of optimization guidelines, and by challenges in cost-efficient manufacturing. This study addresses these limitations with a flexible bioinspired armor based on overlapping ceramic scales. The fabrication combines laser engraving and a stretch-and-release method which allows for fine tuning of the size and overlap of the scales, and which is suitable for large scale fabrication. Compared to a continuous layer of uniform ceramic, our fish-scale like armor is not only more flexible, but it is also more resistant to puncture and more damage tolerant. The proposed armor is also about ten times more puncture resistant than soft elastomers, making it a very attractive alternative to traditional protective equipment.

  12. Learning curve of thyroid fine-needle aspiration biopsy.

    PubMed

    Penín, Manuel; Martín, M Ángeles; San Millán, Beatriz; García, Juana

    2017-12-01

    Fine-needle aspiration biopsy (FNAB) is the reference procedure for thyroid nodule evaluation. Its main limitation are inadequate samples, which should be less than 20%. To analyze the learning curve of the procedure by comparing the results of a non-experienced endocrinologist (endocrinologist 2) to those of an experienced one (endocrinologist 1). Sixty FNABs were analyzed from February to June 2016. Each endocrinologist made 2punctures of every nodule in a random order. This order and the professional making every puncture were unknown to the pathologist who examined the samples. Endocrinologist 1 had a higher percentage of diagnoses than endocrinologist 2 (82% vs. 72%, P=.015). In the first 20 FNABs, the difference between both physicians was remarkable and statistically significant (80% vs. 50%, P=.047). In the following 20 FNABs, the difference narrowed and was not statistically significant (90% vs. 65%, P=.058). In the final 20 FNABs, the difference was minimal and not statistically significant (75% vs. 70%, P=.723). The learning curve of ultrasound-guided FNAB may be completed in a suitable environment by performing it at least 60 times. Although the guidelines recommend at least 3punctures per nodule, 2are enough to achieve an accurate percentage of diagnoses. Copyright © 2017 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. EUS-guided, fine-needle aspiration biopsy using a new mechanical scanning puncture echoendoscope.

    PubMed

    Binmoeller, K F; Brand, B; Thul, R; Rathod, V; Soehendra, N

    1998-05-01

    A new mechanical sector scanning echoendoscope designed for EUS-guided, fine-needle aspiration biopsy (FNAB) was prospectively evaluated. The technical feasibility, safety, and histocytologic FNAB results are reported. Eighty-six patients underwent 106 FNAB procedures. The new echoendoscope has a 2.8 mm accessory channel and an elevator. Target sites: pancreas 58, lymph nodes 43, and miscellaneous lesions 5. Lesions were punctured with a 0.7 mm needle and submitted for cytologic and histologic examination. Definitive diagnosis was by surgery or clinical follow-up. The wide scanning field (250 degrees) enabled easy sonographic orientation for FNAB. Longitudinal needle visibility was "good" in 93% and 71% of transesophageal and transgastric procedures, respectively, but were compromised during most transduodenal procedures. Needle penetration of indurated pancreatic lesions failed in two patients, and in four additional patients pancreatic sampling succeeded only after a second attempt using an automated spring-loaded device. The mean number of passes was three. Ten percent of FNAB specimens were "inadequate"; excluding these, the diagnostic accuracy rate was 97%; sensitivity for malignancy was 88.5% and specificity was 100%. EUS-guided FNAB is feasible, safe, and accurate using the new mechanical puncture echoendoscope. Needle visibility needs to be improved, particularly for transduodenal FNAB.

  14. Endotracheal intubation

    MedlinePlus

    ... bleeding from the esophagus or stomach. Risks include: Bleeding Infection Trauma to the voice box (larynx), thyroid gland, vocal cords and windpipe (trachea), or esophagus Puncture or tearing ( ...

  15. Puncture-Healing Properties of Carbon Nanotube-Filled Ionomers

    NASA Technical Reports Server (NTRS)

    Ward, Thomas C.

    2003-01-01

    Ionomers are polymers that contain ionic groups in relatively low concentrations along the polymer backbone. These ionic groups, in the presence of oppositely charged ions, form aggregates that lead to novel physical properties of the polymer. React-A-Seal(trademark) and Surlyn(trademark) are poly(ethylene-co-methacrylic acid) (EMAA) ionomer-based materials and Nucrel(trademark) is the EMAA acid copolymer neutralized to produce Surlyn(trademark). React-A-Seal(trademark), Surlyn(trademark), and Nucrel(trademark) recover into their original shapes following a high impact puncture at velocities ranging from 300 to 1200 ft/s ('self-healing'). This self-healing process may be of great benefit in space applications where structures are exposed to matter impacts. A thermal IR camera indicated a temperature increase to 98 C for Nucrel(trademark) 925, Surlyn(trademark) 8940, React-A-Seal(trademark), and Surlyn(trademark) 8920 after initial penetration. To understand and generalize the observed phenomena, questions concerning the mechanism of the puncture resealing must be answered. One suggestion is that the elastic character of the melt created by the puncture drives the self-healing. This inference is based on the observed temperature rise of approx. 3 C above the melting temperature of the samples (approx. 95 C) during the impact. With the expectation of gaining additional insight into the self-healing phenomenon, a thermodynamic and viscoelastic investigation was conducted using primarily DSC and DMA. Surlyn(trademark) and React-A-Seal(trademark) showed the characteristic order-disorder transition at approx. 52 C that has been reported in literature. Master curves were constructed from the creep isotherms for the four EMAA samples. An aging study was performed to investigate the irreproducibility and "tailing effect" observed in the creep data. The aging study indicated that, with increased aging time and temperature, changes in the polyethylene matrix lead to complexities in morphology resulting in changes in the magnitude and shape of the creep curves.

  16. The risk of traumatic lumbar punctures in children with acute lymphoblastic leukaemia.

    PubMed

    Shaikh, Furqan; Voicu, Laura; Tole, Soumitra; To, Teresa; Doria, Andrea S; Sung, Lillian; Alexander, Sarah

    2014-05-01

    Traumatic lumbar punctures with blasts (TLP+) in children with acute lymphoblastic leukaemia (ALL) obscure central nervous system status and are associated with a poorer event-free survival (EFS). We conducted a retrospective cohort study of all lumbar punctures (LPs) for children with ALL diagnosed at our institution from 2005 to 2009. We utilised random-effects and fixed-effects repeated-measures logistic regression analyses to identify risk factors for TLPs. Fixed-effects models use each patient as his or her own control. We used survival analysis to describe outcomes after a TLP+. 264 children underwent 5267 evaluable lumbar punctures (LPs), of which 944 (17.9%) were traumatic. In the multivariable random-effects model, variables significantly associated with TLPs were age <1year (odds ratio (OR) 3.46, 95% confidence interval (CI) 2.06-5.81) or age ⩾10years (OR 2.00, CI 1.66-2.40); body mass index percentile ⩾95 (OR 1.44, CI 1.19-1.75); platelet count <100×10(3)/μL (OR 1.49, CI 1.08-20.7); fewer days since previous LP (OR 5.13, CI 2.34-11.25 for ⩾16days versus 0-3days); and a preceding TLP (OR 1.43, CI 1.19-1.73). In the fixed-effects model, image-guidance reduced the odds of TLP (OR 0.55, CI 0.32-0.95). The 5-year EFS (±SE) for children with TLP+ (77±8%) was significantly lower than for children with CNS1 status (93±2%; p=0.002). The frequency of TLP remains high. Consistent with previous studies, a TLP+ at diagnosis was associated with a poorer EFS. These risk factors can allow identifying interventions to reduce TLPs and directing interventions to those at highest risk. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. The Postdural Puncture Headache and Back Pain: The Comparison of 26-gauge Atraucan and 26-gauge Quincke Spinal Needles in Obstetric Patients.

    PubMed

    Akdemir, Mehmet Salim; Kaydu, Ayhan; Yanlı, Yonca; Özdemir, Mehtap; Gökçek, Erhan; Karaman, Haktan

    2017-01-01

    The postdural puncture headache (PDPH) and postdural puncture backache (PDPB) are well-known complications of spinal anesthesia. There are some attempts to reduce the frequency of complication such as different design of the spinal needles. The primary outcome of this study is to compare the incidence of PDPH between 26-gauge Atraucan and 26-gauge Quincke spinal needles in elective cesarean operations. The severity of symptoms, the incidence of backache, technical issues, and comparison of cost of needles are secondary outcomes. After Investigational Review Board approval, a randomized, prospective, double-blinded study was designed in 682 American Society of Anesthesiologists I-II women having elective cesarean operations under spinal anesthesia. Patients were divided into two groups as 26-gauge Atraucan Group A ( n = 323) and 26-gauge Quincke spinal needles Group Q ( n = 342). All patients were questioned about backache 1 week later. Differences between categorical variables were evaluated with Chi-square test. Continuous variables were compared by Student's t -test for two independent groups. A two-sided P < 0.05 was considered statistically significant for all analyses. There were no significant differences between groups in all demographic data. The one attempt success rate of the dural puncture in Group A (70,58%) and in Group Q (69.3%) was similar ( P > 0.05). The incidence of PDPH was 6.5% in Group A and 4.9% in Group Q ( P > 0.05). The epidural blood patch was performed to the three patients in Group A and five patients in Group Q who had severe headache ( P > 0.05). The incidence of PDPB was 4.33% versus 2.04% in Group A and Group Q ( P > 0.05). The incidence of complication rates and technical handling characteristics did not differ between two groups. Quincke needle is cheaper than Atracaun needle, so it can be a cost-effective choice in obstetric patients.

  18. The Postdural Puncture Headache and Back Pain: The Comparison of 26-gauge Atraucan and 26-gauge Quincke Spinal Needles in Obstetric Patients

    PubMed Central

    Akdemir, Mehmet Salim; Kaydu, Ayhan; Yanlı, Yonca; Özdemir, Mehtap; Gökçek, Erhan; Karaman, Haktan

    2017-01-01

    Background: The postdural puncture headache (PDPH) and postdural puncture backache (PDPB) are well-known complications of spinal anesthesia. There are some attempts to reduce the frequency of complication such as different design of the spinal needles. Aims: The primary outcome of this study is to compare the incidence of PDPH between 26-gauge Atraucan and 26-gauge Quincke spinal needles in elective cesarean operations. The severity of symptoms, the incidence of backache, technical issues, and comparison of cost of needles are secondary outcomes. Materials and Methods: After Investigational Review Board approval, a randomized, prospective, double-blinded study was designed in 682 American Society of Anesthesiologists I–II women having elective cesarean operations under spinal anesthesia. Patients were divided into two groups as 26-gauge Atraucan Group A (n = 323) and 26-gauge Quincke spinal needles Group Q (n = 342). All patients were questioned about backache 1 week later. Differences between categorical variables were evaluated with Chi-square test. Continuous variables were compared by Student's t-test for two independent groups. A two-sided P < 0.05 was considered statistically significant for all analyses. Results: There were no significant differences between groups in all demographic data. The one attempt success rate of the dural puncture in Group A (70,58%) and in Group Q (69.3%) was similar (P > 0.05). The incidence of PDPH was 6.5% in Group A and 4.9% in Group Q (P > 0.05). The epidural blood patch was performed to the three patients in Group A and five patients in Group Q who had severe headache (P > 0.05). The incidence of PDPB was 4.33% versus 2.04% in Group A and Group Q (P > 0.05). Conclusions: The incidence of complication rates and technical handling characteristics did not differ between two groups. Quincke needle is cheaper than Atracaun needle, so it can be a cost-effective choice in obstetric patients. PMID:28663641

  19. ELABELA Improves Cardio-Renal Outcome in Fatal Experimental Septic Shock.

    PubMed

    Coquerel, David; Chagnon, Frédéric; Sainsily, Xavier; Dumont, Lauralyne; Murza, Alexandre; Côté, Jérôme; Dumaine, Robert; Sarret, Philippe; Marsault, Éric; Salvail, Dany; Auger-Messier, Mannix; Lesur, Olivier

    2017-11-01

    Apelin-13 was recently proposed as an alternative to the recommended β-adrenergic drugs for supporting endotoxin-induced myocardial dysfunction. Since Apelin-13 signals through its receptor (Apelin peptide jejunum) to exert singular inotropic/vasotropic actions and to optimize body fluid balance, this candidate pathway might benefit septic shock management. Whether the newly discovered ELABELA (ELA), a second endogenous ligand of the Apelin peptide jejunum receptor highly expressed in the kidney, further improves cardio-renal impairment remains unknown. Interventional study in a rat model of septic shock (128 adult males) to assess the effects of ELA and Apelin-13 on vascular and cardio-renal function. Experiments were performed in a tertiary care University-based research institute. Polymicrobial sepsis-induced cardiac dysfunction was produced by cecal ligation puncture to assess hemodynamic efficacy, cardioprotection, and biomechanics under acute or continuous infusions of the apelinergic agonists ELA or Apelin-13 (39 and 15 µg/kg/hr, respectively) versus normal saline. Apelinergic agonists improved 72-hour survival after sepsis induction, with ELA providing the best clinical outcome after 24 hours. Apelinergic agonist infusion counteracted cecal ligation puncture-induced myocardial dysfunction by improving left ventricular pressure-volume relationship. ELA-treated cecal ligation puncture rats were the only group to 1) display a significant improvement in left ventricular filling as shown by increased E-wave velocity and left ventricular end-diastolic volume, 2) exhibit a higher plasma volume, and 3) limit kidney injury and free-water clearance. These beneficial renal effects were superior to Apelin-13, likely because full-length ELA enabled a distinctive regulation of pituitary vasopressin release. Activation of the apelinergic system by exogenous ELA or Apelin-13 infusion improves cardiovascular function and survival after cecal ligation puncture-induced sepsis. However, ELA proved better than Apelin-13 by improving fluid homeostasis, cardiovascular hemodynamics recovery, and limiting kidney dysfunction in a vasopressinergic-dependent manner.

  20. [Localizating and Extracting Small Peripheral Nodules of Lung with Simulating 
Radiaotherapy Combining Methylene Blue Staining].

    PubMed

    Mao, Feng; Zhang, Liang; Gu, Hengle; Zhang, Hui; Lv, Changxing; Shen-Tu, Yang

    2016-09-20

    With the extensively application of HRCT (high resolution CT) and the popularization of early lung cancer screening, the proportion of small nodullar lung cancer to be operated increases rapidly. Identifying the focus lesions quickly and accurately in operation has shown to be a challenge. We carried out this research trying to make use of and evaluate a new method that localizaes and extracts small peripheral pulmonary nodules by way of simulating radiaotherapy combining methylene blue staining. From February 2012 to January 2015, 97 patients with 100 peripheral pulmonary nodules ≤10 mm in size were simulated puncturing using a radiotherapy planning. When the anaesthesia came into use, methylene blue dye was injected to the virtually identified point corresponding to the surface point, according to the angle and depth previously computed by the radiotherapy planning. The video-assisted thoracoscopic surgery (VATS) wedge resections of the marked lesions were undertaken and the specimens were sent for frozen pathologic examination. The interval time from anesthesia-completing to puncture and injection, The interval time from methylene blue injection to identifying the stained area and the distances between the centre point of the stains and edge of coloured lesion were recorded. Our preoperative localization procedure was successful in 96 of 100 (96%) nodules. The interval time from anesthesia-completing to puncture and injection of methylene blue were (4.85±1.25) min. The interval time from methylene blue injection to identifying the stained area was (16.36±2.36) min. The distances between the centre point of the stains and edge of coloured lesion were (4.78±2.51) mm. No complication was observed in all participants. The new method of locating peripheral pulmonary nodules by simulating simulating radiaotherapy combining methylene blue staining has a high success rate and no complication for localizing small peripheral pulmonary lesions, avoiding the fear and pain of the patients untaken puncture without anaesthesia reducing radial damage.

  1. Obesity: An Independent Risk Factor for Insufficient Hemostasis Using the AngioSeal Vascular Closure Device After Antegrade Puncture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Minko, Peter, E-mail: peterminko@yahoo.com; Katoh, Marcus; Graeber, Stefan

    Purpose: This study was designed to investigate the efficacy of the AngioSeal vascular closure device after antegrade puncture of the femoral artery. Methods: In a prospective study, 120 consecutive patients underwent lower limb vascular intervention by an antegrade access to the common femoral artery (CFA). After intervention, a 6F (n = 88) or an 8F (n = 32) AngioSeal vascular closure device was used to achieve hemostasis. The technical success or the cause of failure was documented. In addition, the coagulation status (platelets, INR, prothrombin time, atrial thromboplastin time (PTT)), hypertonus, locoregional habitus of the groin, body mass index (BMI),more » presence of calcifications, and history of previous surgical interventions of the CFA were evaluated. Results: Hemostasis was achieved in 97 patients (81%). In 12 patients (10%), persistent bleeding of the puncture site required manual compression. In another nine patients (8%) a kink of the sheath obviated the passage of the collagen plug toward the vessel, and in two patients the anchor dislodged out of the vessel, requiring manual compression. There were no significant differences between the groups of successful and unsuccessful sealing regarding the mean platelets (241 vs. 254 * 10{sup 9}/l; P = 0.86), INR (1.06 vs. 1.02; P = 0.52), prothrombin time (90% vs. 90%; P = 0.86), and PTT (30 vs. 31 s; P = 0.82). However, unsuccessful sealing was more likely in obese patients with an increased BMI (26.6 vs. 28.8 kg/m{sup 2}; P = 0.04). Conclusions: Obesity seems to be an independent risk factor for insufficient sealing using the AngioSeal vascular closure device after antegrade puncture of the CFA. In 8% of our patients, hemostasis could not be achieved due to kink of the flexible sheath.« less

  2. A comparison of longitudinal and transverse approaches to ultrasound-guided axillary vein cannulation by experienced operators

    PubMed Central

    He, Yi-Zhou; Zhong, Ming; Wu, Wei; Song, Jie-Qiong

    2017-01-01

    Background The axillary vein is an easily accessible vessel that can be used for ultrasound-guided central vascular access and offers an alternative to the internal jugular and subclavian veins. The objective of this study was to identify which transducer orientation, longitudinal or transverse, is better for imaging the axillary vein with ultrasound. Methods We analyzed 236 patients who had undergone central venous cannulation of axillary vein in this retrospective study. Patients were divided into two groups, the longitudinal approach group (n=120) and transverse approach group (n=116). Recorded the one-attempt success rate, operation time, arterial puncture rate and pneumothorax rate. We perform chest radiography to confirm pneumothorax on all patients. We compared the one-attempt success rate, operation time, arterial puncture rate and pneumothorax rate between the two groups. Results The two groups were comparable with clinical characters of patients. The overall success rates of the longitudinal group and the transverse group were both 100%. The rate of one-attempt success in the longitudinal approach group is higher than the transverse approach group (91.7% vs. 82.8%, P=0.040). The transverse approach group had shorter operation time than the longitudinal group (184.7±8.1 vs. 287.5±19.6 seconds, P=0.000). The two groups had lower postoperative complications. Arterial puncture occurred in 1 of 120 longitudinal and 2 of 116 transverse attempts and this difference was no significant (P=0.541). No pneumothorax occurred in the two groups. Conclusions The longitudinal approach during ultrasound-guided axillary vein cannulation is associated with greater one-attempt success rate compared with the transverse approach by experienced operators. The transverse approach has shorter operation time. The two groups have lower postoperative complications and are comparable with pneumothorax and arterial puncture. PMID:28523170

  3. Puncture initial data for black-hole binaries with high spins and high boosts

    NASA Astrophysics Data System (ADS)

    Ruchlin, Ian; Healy, James; Lousto, Carlos O.; Zlochower, Yosef

    2017-01-01

    We solve the Hamiltonian and momentum constraints of general relativity for two black holes with nearly extremal spins and relativistic boosts in the puncture formalism. We use a non-conformally-flat ansatz with an attenuated superposition of two Lorentz-boosted, conformally Kerr or conformally Schwarzschild 3-metrics and their corresponding extrinsic curvatures. We compare evolutions of these data with the standard Bowen-York conformally flat ansatz (technically limited to intrinsic spins χ =S /MADM2=0.928 and boosts P /MADM=0.897 ), finding, typically, an order of magnitude smaller burst of spurious radiation and agreement with inspiral and merger. As a first case study, we evolve two equal-mass black holes from rest with an initial separation of d =12 M and spins χi=Si/mi2=0.99 , compute the waveforms produced by the collision, the energy and angular momentum radiated, and the recoil of the final remnant black hole. We find that the black-hole trajectories curve at close separations, leading to the radiation of angular momentum. We also study orbiting nonspinning and moderate-spin black-hole binaries and compare these with standard Bowen-York data. We find a substantial reduction in the nonphysical initial burst of radiation which leads to cleaner waveforms. Finally, we study the case of orbiting binary black-hole systems with spin magnitude χi=0.95 in an aligned configuration and compare waveform and final remnant results with those of the SXS Collaboration [54 A. H. Mroue et al., Phys. Rev. Lett. 111, 241104 (2013)., 10.1103/PhysRevLett.111.241104], finding excellent agreement. This represents the first moving puncture evolution of orbiting and spinning black holes exceeding the Bowen-York limit. Finally, we study different choices of the initial lapse and lapse evolution equation in the moving puncture approach to improve the accuracy and efficiency of the simulations.

  4. In vitro bacterial cytotoxicity of CNTs: reactive oxygen species mediate cell damage edges over direct physical puncturing.

    PubMed

    Rajavel, Krishnamoorthy; Gomathi, Rajkumar; Manian, Sellamuthu; Rajendra Kumar, Ramasamy Thangavelu

    2014-01-21

    Understanding the bacterial cytotoxicity of CNTs is important for a wide variety of applications in the biomedical, environmental, and health sectors. A majority of the earlier reports attributed the bactericidal cytotoxicity of CNTs to bacterial cell membrane damage by direct physical puncturing. Our results reveal that bacterial cell death via bacterial cell membrane damage is induced by reactive oxygen species (ROS) produced from CNTs and is not due to direct physical puncturing by CNTs. To understand the actual mechanism of bacterial killing, we elucidated the bacterial cytotoxicity of SWCNTs and MWCNTs against Gram-negative human pathogenic bacterial species Escherichia coli, Shigella sonnei, Klebsiella pneumoniae, and Pseudomonas aeruginosa and its amelioration upon functionalizing the CNTs with antioxidant tannic acid (TA). Interestingly, the bacterial cells treated with CNTs exhibited severe cell damage under laboratory (ambient) and sunlight irradiation conditions. However, CNTs showed no cytotoxicity to the bacterial cells when incubated in the dark. The quantitative assessments carried out by us made it explicit that CNTs are effective generators of ROS such as (1)O2, O2(•-), and (•)OH in an aqueous medium under both ambient and sunlight-irradiated conditions. Both naked and TA-functionalized CNTs showed negligible ROS production in the dark. Furthermore, strong correlations were obtained between ROS produced by CNTs and the bacterial cell mortality (with the correlation coefficient varying between 0.7618 and 0.9891) for all four tested pathogens. The absence of bactericidal cytotoxicity in both naked and functionalized CNTs in the dark reveals that the presence of ROS is the major factor responsible for the bactericidal action compared to direct physical puncturing. This understanding of the bactericidal activity of the irradiated CNTs, mediated through the generation of ROS, could be interesting for novel applications such as regulated ROS delivery in cancer therapy and the sanitation of potable water supplies.

  5. Spectrophotometry or visual inspection to most reliably detect xanthochromia in subarachnoid hemorrhage: systematic review.

    PubMed

    Chu, Kevin; Hann, Angus; Greenslade, Jaimi; Williams, Julian; Brown, Anthony

    2014-09-01

    We assess the sensitivity and specificity of xanthochromia as adjudicated by visual inspection and spectrophotometry at predicting the presence of cerebral aneurysm in patients with suspected subarachnoid hemorrhage who have a normal computed tomography (CT) head scan result. A systematic review was performed. MEDLINE and EMBASE databases were searched. Relevant studies with clinical data on the diagnostic accuracy of visual inspection or spectrophotometry were considered. Patients who had a normal CT head scan result followed by a lumbar puncture were included in this review. Sensitivities, specificities, and heterogeneity (I(2)) were calculated. Subgroup analyses were performed to explore reasons for the heterogeneity. There were major methodological limitations in the studies found. Twenty-two relevant articles were heterogeneous in regard to time to lumbar puncture, spectrophotometry methods, and follow-up of patients not undergoing cerebral angiography. Twelve of the 22 studies selected patients on the basis of a cerebral aneurysm or subarachnoid hemorrhage on imaging, or a positive lumbar puncture result. These studies were excluded from our initial analysis, which included only patients with clinically suspected subarachnoid hemorrhage. In this initial analysis, pooled estimates of sensitivity and specificity for spectrophotometry were 87% (95% confidence interval [CI] 71% to 96%; I(2)=26%) and 86% (95% CI 84% to 88%; I(2)=96%), respectively. For visual inspection, pooled sensitivity and specificity were 83% (95% CI 59% to 96%; I(2)=52%) and 96% (95% CI 93% to 97%; I(2)=76%), respectively. Sensitivity estimates are difficult to interpret without knowing time to lumbar puncture. The heterogeneity in the underlying studies, combined with significant overlap in pooled confidence limits, makes it impossible to provide a definite conclusion about the diagnostic accuracy of spectrophotometry versus visual inspection. Copyright © 2014 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.

  6. AdS5 solutions from M5-branes on Riemann surface and D6-branes sources

    DOE PAGES

    Bah, Ibrahima

    2015-09-24

    Here, we describe the gravity duals of four-dimensional N = 1 superconformal field theories obtained by wrapping M5-branes on a punctured Riemann surface. The internal geometry, normal to the AdS 5 factor, generically preserves two U(1)s, with generators (J +, J –), that are fibered over the Riemann surface. The metric is governed by a single potential that satisfies a version of the Monge-Ampère equation. The spectrum of N = 1 punctures is given by the set of supersymmetric sources of the potential that are localized on the Riemann surface and lead to regular metrics near a puncture. We usemore » this system to study a class of punctures where the geometry near the sources corresponds to M-theory description of D6-branes. These carry a natural (p, q) label associated to the circle dual to the killing vector pJ + + qJ – which shrinks near the source. In the generic case the world volume of the D6-branes is AdS 5 × S 2 and they locally preserve N = 2 supersymmetry. When p = –q, the shrinking circle is dual to a flavor U(1). The metric in this case is non-degenerate only when there are co-dimension one sources obtained by smearing M5-branes that wrap the AdS 5 factor and the circle dual the superconformal R-symmetry. The D6-branes are extended along the AdS 5 and on cups that end on the co-dimension one branes. In the special case when the shrinking circle is dual to the R-symmetry, the D6-branes are extended along the AdS 5 and wrap an auxiliary Riemann surface with an arbitrary genus. When the Riemann surface is compact with constant curvature, the system is governed by a Monge-Ampère equation.« less

  7. Autonomic Responses to Ultrasound-Guided Percutaneous Needle Electrolysis: Effect of Needle Puncture or Electrical Current?

    PubMed

    García Bermejo, Paula; De La Cruz Torres, Blanca; Naranjo Orellana, José; Albornoz Cabello, Manuel

    2018-01-01

    The aim of this study was to establish if the changes in sympathetic and parasympathetic activity (analyzed through heart-rate variability [HRV]) during ultrasound (US)-guided percutaneous needle electrolysis (PNE) is due to the effect of needle puncture only or of the PNE technique per se where the puncture and galvanic current are combined. This was an experimental, case-control study that took place at the University of Seville. Subjects were 36 male footballers who were randomly allocated to three groups: a control group (CG; 12 players), for whom HRV was recorded for 10 min, both at rest and during an exhaustive US examination of the patellar tendon and adjacent structures; a first experimental group (PNE group; 12 players), for whom HRV was recorded for 10 min, both at rest and during application of US-guided PNE in the patellar tendon; and a second experimental group (needle group; 12 players), for whom HRV was recorded for 10 min, both at rest and during application of US-guided PNE without electrical current in the patellar tendon. The outcome measures were the diameters of the Poincaré plot (SD1, SD2), stress score, and sympathetic/parasympathetic ratio. There were no differences between groups in any baseline measurements, nor were there any significant differences between CG measurements (baseline vs. intervention). The PNE group exhibited statistically significant increases in SD1 (p = 0.01) and SD2 (p = 0.004) and statistically significant decreases in SS and S/PS ratio (p = 0.03), indicating increased parasympathetic and decreased sympathetic activity, respectively. The needle group exhibited statistically significant increases in SD2 (p = 0.02) and statistically significant decreases in SS (p = 0.02), indicating decreased sympathetic activity. The application of the US-guided PNE technique caused a measurable increase in parasympathetic activity (detected by HRV), which was due to the combination of needle puncture and electric current.

  8. Intervention Planning Using a Laser Navigation System for CT-Guided Interventions: A Phantom and Patient Study

    PubMed Central

    Lee, Clara; Bolck, Jan; Naguib, Nagy N.N.; Schulz, Boris; Eichler, Katrin; Aschenbach, Rene; Wichmann, Julian L.; Vogl, Thomas. J.; Zangos, Stephan

    2015-01-01

    Objective To investigate the accuracy, efficiency and radiation dose of a novel laser navigation system (LNS) compared to those of free-handed punctures on computed tomography (CT). Materials and Methods Sixty punctures were performed using a phantom body to compare accuracy, timely effort, and radiation dose of the conventional free-handed procedure to those of the LNS-guided method. An additional 20 LNS-guided interventions were performed on another phantom to confirm accuracy. Ten patients subsequently underwent LNS-guided punctures. Results The phantom 1-LNS group showed a target point accuracy of 4.0 ± 2.7 mm (freehand, 6.3 ± 3.6 mm; p = 0.008), entrance point accuracy of 0.8 ± 0.6 mm (freehand, 6.1 ± 4.7 mm), needle angulation accuracy of 1.3 ± 0.9° (freehand, 3.4 ± 3.1°; p < 0.001), intervention time of 7.03 ± 5.18 minutes (freehand, 8.38 ± 4.09 minutes; p = 0.006), and 4.2 ± 3.6 CT images (freehand, 7.9 ± 5.1; p < 0.001). These results show significant improvement in 60 punctures compared to freehand. The phantom 2-LNS group showed a target point accuracy of 3.6 ± 2.5 mm, entrance point accuracy of 1.4 ± 2.0 mm, needle angulation accuracy of 1.0 ± 1.2°, intervention time of 1.44 ± 0.22 minutes, and 3.4 ± 1.7 CT images. The LNS group achieved target point accuracy of 5.0 ± 1.2 mm, entrance point accuracy of 2.0 ± 1.5 mm, needle angulation accuracy of 1.5 ± 0.3°, intervention time of 12.08 ± 3.07 minutes, and used 5.7 ± 1.6 CT-images for the first experience with patients. Conclusion Laser navigation system improved accuracy, duration of intervention, and radiation dose of CT-guided interventions. PMID:26175571

  9. Emergency medical technician-performed point-of-care blood analysis using the capillary blood obtained from skin puncture.

    PubMed

    Kim, Changsun; Kim, Hansol

    2017-12-09

    Comparing a point-of-care (POC) test using the capillary blood obtained from skin puncture with conventional laboratory tests. In this study, which was conducted at the emergency department of a tertiary care hospital in April-July 2017, 232 patients were enrolled, and three types of blood samples (capillary blood from skin puncture, arterial and venous blood from blood vessel puncture) were simultaneously collected. Each blood sample was analyzed using a POC analyzer (epoc® system, USA), an arterial blood gas analyzer (pHOx®Ultra, Nova biomedical, USA) and venous blood analyzers (AU5800, DxH2401, Beckman Coulter, USA). Twelve parameters were compared between the epoc and reference analyzers, with an equivalence test, Bland-Altman plot analysis and linear regression employed to show the agreement or correlation between the two methods. The pH, HCO 3 , Ca 2+ , Na + , K + , Cl - , glucose, Hb and Hct measured by the epoc were equivalent to the reference values (95% confidence interval of mean difference within the range of the agreement target) with clinically inconsequential mean differences and narrow limits of agreement. All of them, except pH, had clinically acceptable agreements between the two methods (results within target value ≥80%). Of the remaining three parameters (pCO 2, pO 2 and lactate), the epoc pCO 2 and lactate values were highly correlated with the reference device values, whereas pO 2 was not. (pCO 2 : R 2 =0.824, y=-1.411+0.877·x; lactate: R 2 =0.902, y=-0.544+0.966·x; pO 2 : R 2 =0.037, y=61.6+0.431·x). Most parameters, except only pO 2 , measured by the epoc were equivalent to or correlated with those from the reference method. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. A Web-based Decision Tool to Estimate Subarachnoid Hemorrhage Risk in Emergency Department Patients

    PubMed Central

    Manella, Haley; Sivasankar, Shyam; Perry, Jeffrey J; Pfeil, Sam; Senyak, Josh; Shachter, Ross

    2018-01-01

    Subarachnoid hemorrhage (SAH) from a leaking aneurysm is a neurological emergency. SAH patients often present with headache—a common chief complaint among emergency department patients. If unrecognized, 70% of the patients with re-bleeds die and one third are left with neurological deficits. Therefore, it is critical to distinguish the signs and symptoms of SAH from benign causes of headache, perform the appropriate diagnostic tests and treat in a timely manner in order to reduce the disability and mortality associated with this condition. In patients with suspected SAH, traditional diagnostic strategies in the emergency department employ non-contrast computed tomography (CT) of the brain to detect blood in the subarachnoid space followed by lumbar puncture if there is a high clinical probability of aneurysmal bleed without any evidence of blood on CT scan. While the older generation CT scanners were less sensitive to blood detection in the subarachnoid space, recent advances in CT imaging have resulted in sensitivity approaching 100% for detection of blood in the subarachnoid space specifically within six hours of symptom onset. Therefore, the benefit of lumbar puncture is controversial when performed within the first six hours of symptom onset. Despite this, lumbar puncture is still commonly performed in the emergency department, exposing patients to unnecessary procedural risks. The objective of this research study is to develop a web-based risk calculator that estimates the risk of SAH based on time to emergency department presentation after symptom onset, physical findings and imaging characteristics with the goal of reducing unnecessary lumbar punctures in the emergency department. In this technical report, we describe the prototype calculator, the mathematical basis of the model and provide a link to the web-based prototype. In the future, we will refine the prototype, make it user-friendly to physicians, staff and patients and study its benefits in the emergency department. PMID:29568717

  11. 21 CFR 522.563 - Diatrizoate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... inject 5 to 10 mL directly into the heart via catheter or intraventricular puncture. For cerebral...; angiocardiography, peripheral arteriography, and venography; selective coronary arteriography; cerebral angiography...

  12. The moduli space of vacua of $$ \\mathcal{N}=2 $$ class $$ \\mathcal{S} $$ theories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xie, Dan; Yonekura, Kazuya

    We develop a systematic method to describe the moduli space of vacua of four dimensional N=2 class S theories including Coulomb branch, Higgs branch and mixed branches. In particular, we determine the Higgs and mixed branch roots, and the dimensions of the Coulomb and Higgs components of mixed branches. They are derived by using generalized Hitchin’s equations obtained from twisted compactification of 5d maximal Super-Yang-Mills, with local degrees of freedom at punctures given by (nilpotent) orbits. The crucial thing is the holomorphic factorization of the Seiberg-Witten curve and reduction of singularity at punctures. We illustrate our method by many examplesmore » including N=2 SQCD, T N theory and Argyres-Douglas theories.« less

  13. Pressure Control In A Tyre Of Moving Vehicle

    NASA Astrophysics Data System (ADS)

    Gawande, Kshitij P.; Jawanjal, Vaishakh A.

    2012-08-01

    We always try to make everything perfect around us and there is major problem still remaining in our automobiles, a puncture in a tire while running. We have developed tubeless tires but thatís not a perfect solution, so there is a serious need of improvement in this area. In this paper the compressed air is used to maintain the pressure in the tire using pneumatic pipes. This is a very basic concept which uses compressor power to maintain the pressure of a tire, while running using pressure gauges and leak proof connection. This technique allows us to drive a punctured vehicle which increases safety, comfort & saves time. This paper suggests a new technique towards one more improvement in our automobile industry.

  14. Continuous Spinal Anesthesia for Obstetric Anesthesia and Analgesia

    PubMed Central

    Veličković, Ivan; Pujic, Borislava; Baysinger, Charles W.; Baysinger, Curtis L.

    2017-01-01

    The widespread use of continuous spinal anesthesia (CSA) in obstetrics has been slow because of the high risk for post-dural puncture headache (PDPH) associated with epidural needles and catheters. New advances in equipment and technique have not significantly overcome this disadvantage. However, CSA offers an alternative to epidural anesthesia in morbidly obese women, women with severe cardiac disease, and patients with prior spinal surgery. It should be strongly considered in parturients who receive an accidental dural puncture with a large bore needle, on the basis of recent work suggesting significant reduction in PDPH when intrathecal catheters are used. Small doses of drug can be administered and extension of labor analgesia for emergency cesarean delivery may occur more rapidly compared to continuous epidural techniques. PMID:28861414

  15. Microbiology for Radiologists: How to Minimize Infection Transmission in the Radiology Department.

    PubMed

    Mirza, Sobia K; Tragon, Tyson R; Fukui, Melanie B; Hartman, Matthew S; Hartman, Amy L

    2015-01-01

    The implementation of standardized infection control and prevention practices is increasingly relevant as modern radiology practice evolves into its more clinical role. Current Centers for Disease Control and Prevention, National Institutes of Health, and World Health Organization guidelines for the proper use of personal protective equipment, decontamination of reusable medical equipment, and appropriate management of bloodborne pathogen exposures will be reviewed. Standard precautions apply to all patients at all times and are the mainstay of infection control. Proper hand hygiene includes washing hands with soap and water when exposed to certain infectious particles, such as Clostridium difficile spores, which are not inactivated by alcohol-based hand rubs. The appropriate use of personal protective equipment in accordance with recommendations from the Centers for Disease Control and Prevention includes wearing a surgical mask during lumbar puncture. Because radiologists may perform lumbar punctures for patients with prion disease, it is important to appreciate that incineration is the most effective method of inactivating prion proteins. However, there is currently no consensus recommendation on the decontamination of prion-contaminated reusable items associated with lumbar puncture, and institutional policies should be consulted for directed management. In the event of a needlestick injury, radiology staff must be able to quickly provide appropriate initial management and seek medical attention, including laboratory testing for bloodborne pathogens. ©RSNA, 2015.

  16. Ultrasound-guided transhepatic puncture of the hepatic veins for TIPS placement.

    PubMed

    Gazzera, C; Fonio, P; Gallesio, C; Camerano, F; Doriguzzi Breatta, A; Righi, D; Veltri, A; Gandini, G

    2013-04-01

    This retrospective analysis was carried out to assess the feasibility and results of transjugular intrahepatic portal systemic shunt (TIPS) performed with ultrasound (US)-guided percutaneous puncture of the hepatic veins. Over a period of 3 years, 153 patients were treated with TIPS at our centre. In eight cases, a percutaneous puncture of the middle (n=7) or right (n=1) hepatic vein was required because the hepatic vein ostium was not accessible. Indications for TIPS were bleeding (n=1), Budd-Chiari syndrome (n=1), ascites (n=2), reduced portal flow (n=1) and incomplete portal thrombosis (n=3). A 0.018-in. guidewire was anterogradely introduced into the hepatic vein to the inferior vena cava (IVC) through a 21-gauge needle. In the meantime, a 25-mm snare-loop catheter was introduced through the jugular access to retrieve the guidewire, achieving through-andthrough access. Then, a Rosch-Uchida set was used to place the TIPS with the traditional technique. Technical success was achieved in all patients. There was one case of stent thrombosis. One patient died of pulmonary oedema. Three patients were eligible for liver transplantation, whereas the others were excluded due to shunt thrombosis (n=1) and previous nonhepatic neoplasms (n=3). The percutaneous approach to hepatic veins is rapid and safe and may be useful for avoiding traumatic liver injuries.

  17. Intraosseous Vascular Access through the Anterior Mandible – A Cadaver Model Pilot Study

    PubMed Central

    Goldschalt, Christin; Doll, Sara; Ihle, Brit; Kirsch, Joachim; Mutzbauer, Till Sebastian

    2014-01-01

    Background Several insertion sites have been described for intraosseous puncture in cases of emergencies when a conventional vascular access cannot be established. This pilot study has been designed to evaluate the feasibility of the mandibular bone for the use of an intraosseous vascular access in a cadaver model. Methodology/Principal Findings 17 dentistry and 16 medical students participating in a voluntary course received a short introduction into the method and subsequently used the battery powered EZ-IO system with a 15 mm cannula for a puncture of the anterior mandible in 33 cadavers. The time needed to perform each procedure was evaluated. India ink was injected into the accesses and during the anatomy course cadavers were dissected to retrace the success or failure of the puncture. Dental students needed 25.5±18.9(mean±standard deviation)s and medical students 33±20.4 s for the procedure (p = 0.18). Floor of mouth extravasation occurred in both groups in 3 cases. Success rates were 82 and 75% (p = 0.93). Conclusions/Significance Despite floor of mouth extravasation of injected fluid into a mandibular intraosseous access might severely complicate this procedure, the anterior mandible may be helpful as an alternative to other intraosseous and intravenous insertion sites when these are not available in medical emergencies. PMID:25405476

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heberlein, Wolf E., E-mail: weheberlein@uams.edu; Goodwin, Whitney J.; Wood, Clint E.

    Purpose: Our study evaluated techniques for percutaneous gastrostomy (G)-tube placement without the use of a nasogastric (NG) tube. Instead, direct puncture of a physiologic air bubble or effervescent-enhanced gastric bubble distention was performed in patients with upper digestive tract obstruction (UDTO) or psychological objections to NG tubes. Materials and Methods: A total of 886 patients underwent G-tube placement in our department during a period of 7 years. We present our series of 85 (9.6%) consecutive patients who underwent percutaneous G-tube placement without use of an NG tube. Results: Of these 85 patients, fluoroscopic guided access was attempted by direct puncturemore » of a physiologically present gastric air bubble in 24 (28%) cases. Puncture of an effervescent-induced large gastric air bubble was performed in 61 (72%) patients. Altogether, 82 (97%) of 85 G tubes were successfully placed in this fashion. The three failures comprised refusal of effervescent, vomiting of effervescent, and one initial tube misplacement when a deviation from our standard technique occurred. Conclusion: The described techniques compare favorably with published large series on G-tube placement with an NG tube in place. The techniques are especially suited for patients with UDTO due to head, neck, or esophageal malignancies, but they should be considered as an alternative in all patients. Direct puncture of effervescent-enhanced gastric bubble distention is a safe, patient-friendly and effective technique.« less

  19. Nonoperative Management of Extravasation Injuries Associated With Neonatal Parenteral Nutrition Using Multiple Punctures and a Hydrocolloid Dressing.

    PubMed

    Sung, Kun-Yong; Lee, Sang-Yeul

    2016-05-01

    Neonatal extravasation injuries are often associated with peripheral parenteral nutrition. Several treatment modalities have been developed and used for managing these injuries with variable results. However, there is a lack of consensus regarding the management of neonatal extravasation injuries. The aim of this paper is to introduce a new nonoperative method for the treatment of neonatal extravasation injuries associated with parenteral nutrition. The authors made multiple punctures on the extravasated wound using a No. 11 scalpel blade tip and applying a DuoDERM Extra Thin (ConvaTec Inc, Princeton, NJ) dressing, a hydrocolloid dressing. The dressing was changed every 6 hours on the first day, and dressing changes were continued with decreasing frequency according to the amount of exudate until the wound healed. After the devitalized tissue began to demarcate and autolyse, surgical debridement was gradually performed. Twelve neonatal extravasation injuries, which occurred between November 2010 and June 2014, were evaluated. The mean follow-up duration was 10 months. The average duration of treatment for wound healing was 25 days. All wounds healed without func- tional deficits and conspicuous scars. The authors suggest their new method of using multiple punctures and a hydrocolloid dressing is an easy, effective, and minimally invasive treatment for neonatal extravasation injuries associated with peripheral parenteral nutrition, and it can be used as an alternative treatment option.

  20. The anatomical relationship between the axillary artery and vein investigated by radial coronary angiography.

    PubMed

    Sert, Sena; Kepez, Alper; Atas, Halil; Mutlu, Bulent; Erdogan, Okan

    2018-06-01

    To reduce the risk of inadvertent arterial puncture and bleeding, we aimed to define a safe puncture site by demonstrating the relation of the axillary artery and vein. The anatomical course and relation as well as crossover sites of the axillary artery and vein, the presence of small arterial bridges over the axillary vein, and validation of commonly preferred axillary venous puncture sites were determined by simultaneous ipsilateral venography in patients (n  =  111; 80 men, age 60 ± 10 years) who underwent coronary angiography by radial artery access. The axillary vein was detected at the first costa-clavicular intersection in 62% and at the second anterior and third posterior costal intersection in 60% of the patients. Small arterial bridges over the axillary vein were observed in 77% of the patients and more frequently in females and body mass index ≥25 kg/m 2 (P  =  0.034 and P  =  0.03, respectively). The axillary artery crossed the vein in 24% of the patients and almost always within the region close to the first costa-clavicular intersection site. Our study demonstrated a high crossover rate (24%) of axillary artery and vein and a high degree of variation in the course of axillary vein. Small arterial bridges over the axillary vein were observed in 77% of the patients. © 2018 Wiley Periodicals, Inc.

  1. Needle tip visualization by bevel-point ultrasound generator and prototype photoacoustic imaging system

    NASA Astrophysics Data System (ADS)

    Irisawa, Kaku; Murakoshi, Dai; Hashimoto, Atsushi; Yamamoto, Katsuya; Hayakawa, Toshiro

    2017-03-01

    Visualization of the tip of medical devices like needles or catheters under ultrasound imaging has been a continuous topic since the early 1980's. In this study, a needle tip visualization system utilizing photoacoustic effects is proposed. In order to visualize the needle tip, an optical fiber was inserted into a needle. The optical fiber tip is placed on the needle bevel and affixed with black glue. The pulsed laser light from laser diode was transferred to the optical fiber and converted to ultrasound due to laser light absorption of the black glue and the subsequent photoacoustic effect. The ultrasound is detected by transducer array and reconstructed into photoacoustic images in the ultrasound unit. The photoacoustic image is displayed with a superposed ultrasound B-mode image. As a system evaluation, the needle is punctured into bovine meat and the needle tip is observed with commercialized conventional linear transducers or convex transducers. The needle tip is visualized clearly at 7 and 12 cm depths with linear and convex probes, respectively, even with a steep needle puncture angle of around 90 degrees. Laser and acoustic outputs, and thermal rise at the needle tip, were measured and were well below the limits of the safety standards. Compared with existing needle tip visualization technologies, the photoacoustic needle tip visualization system has potential distinguishable features for clinical procedures related with needle puncture and injection.

  2. Lumbar puncture requirement in acute hemiparesis: diagnosis of tuberculous meningitis after hemiparesis in a child.

    PubMed

    Sahin, Sevim; Cansu, Ali; Kamaşak, Tülay; Eyüboğlu, İlker; Esenülkü, Gülnur; Ökten, Ayşenur

    2014-12-01

    Infections are an important acquired cause of cerebral arteriopathy. Tuberculous (TB) meningitis leading to infectious cerebral vasculopathy is a rare cause of acute hemiparesis. A 14-year-old male patient was examined after acute hemiparesis developing within 1 day. Neurological examination revealed total hemiplegia on the left side. Brain MRI findings showed bilateral focal T2-weighted signal hyperintensity in the subcortical and deep white matter regions. There were also areas of restricted diffusion in the right basal ganglia. Although the father had a history of pulmonary TB, the patient had not been given TB prophylaxis because of PPD negativity. At lumbar puncture, opening cerebrospinal fluid (CSF) pressure was 50 cm/H20, CSF protein 66.9 mg/dL, and glucose 54 mg/dL (concurrent blood glucose 93 mg/dL); 170 polymorphonuclear leukocytes per cubic millimeter were present in CSF. Following tests for TB, treatment was started immediately with four anti-TB drugs. TB PCR of CSF and acid-fast bacteria (AFB) staining in gastric aspirate were positive. At clinical follow-up, the patient was able to walk with support at the end of the first month. Various infectious agents have been reported as causes of cerebral vasculopathy. TB, which affects a significant number of patients worldwide, should be kept in mind in terms of cerebral vascular complications. Lumbar puncture is essential in order to diagnose TB meningitis.

  3. Meningitis

    MedlinePlus

    ... and spinal cord. This covering is called the meninges. Causes The most common causes of meningitis are ... Kernig's sign of meningitis Lumbar puncture (spinal tap) Meninges of the brain Meninges of the spine Haemophilus ...

  4. 21 CFR 522.563 - Diatrizoate meglumine and diatrizoate sodium injection.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., peripheral arteriography, and venography; selective coronary arteriography; cerebral angiography... intraventricular puncture. For cerebral angiography rapid injection of 3 to 10 milliliters via carotid artery. For...

  5. 21 CFR 522.563 - Diatrizoate meglumine and diatrizoate sodium injection.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., peripheral arteriography, and venography; selective coronary arteriography; cerebral angiography... intraventricular puncture. For cerebral angiography rapid injection of 3 to 10 milliliters via carotid artery. For...

  6. 21 CFR 522.563 - Diatrizoate meglumine and diatrizoate sodium injection.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., peripheral arteriography, and venography; selective coronary arteriography; cerebral angiography... intraventricular puncture. For cerebral angiography rapid injection of 3 to 10 milliliters via carotid artery. For...

  7. 21 CFR 522.563 - Diatrizoate meglumine and diatrizoate sodium injection.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., peripheral arteriography, and venography; selective coronary arteriography; cerebral angiography... intraventricular puncture. For cerebral angiography rapid injection of 3 to 10 milliliters via carotid artery. For...

  8. Methylnaltrexone Injection

    MedlinePlus

    ... puncture resistant container into the household trash or recycling. Talk to your doctor or pharmacist about how ... to your pharmacist or contact your local garbage/recycling department to learn about take-back programs in ...

  9. Pseudotumor cerebri syndrome

    MedlinePlus

    ... problems. Repeat lumbar punctures are helpful for pregnant women in order to delay surgery until after delivery. Other treatments may include: Fluid or salt restriction Medicines such as corticosteroids, acetazolamide, furosemide, and topiramate ...

  10. Mechanical properties of sugar beet root during storage

    NASA Astrophysics Data System (ADS)

    Nedomová, Šárka; Kumbár, Vojtěch; Pytel, Roman; Buchar, Jaroslav

    2017-10-01

    This paper is an investigation via two experimental methods, of the textural properties of sugar beet roots during the storage period. In the work, sugar beet roots mechanical properties were evaluated during the post-harvest period - 1, 8, 22, 43, and 71 days after crop. Both experimental methods, i.e. compression test and puncture test, suggest that the failure strength of the sugar beet root increases with the storage time. The parameters obtained using the puncture test, are more sensitive to the storage duration than those obtained by way of the compression test. We also found that such mechanical properties served as a reliable tool for monitoring the progress of sugar beet roots storage. The described methods could also be used to highlight important information on sugar beet evolution during storage.

  11. Preparation, Purification, and Stability of Tuberculin

    PubMed Central

    Landi, S.

    1963-01-01

    The method used to produce “Connaught” tuberculin purified protein derivative (PPD) is described. The tuberculin PPD for the multiple-puncture method was shown to be stable for at least 24 months at 5 C; tuberculin PPD for the intracutaneous method was shown to be stable at 5 C and 24 C for a period of 18 months in the presence of Tween 80. Evans blue or brillant vital red was added to tuberculin PPD for improved testing by the multiple-puncture method. These tinted tuberculin preparations were found to be as stable as the Connaught tuberculin PPD preparations without dye at 5 C. Freeze-dried tuberculin PPD with Plasdone as an inert base was found to be remarkably stable for a period of at least 24 months at 5, 24, and 37 C. PMID:14063782

  12. Endosonography and cytology in diagnosing and staging pancreatic body and tail carcinoma: Preliminary results of endosonographic guided puncture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tio, T.L.; Sie, L.H.; Tytgat, G.N.J.

    1993-01-01

    Endosonography was performed in diagnosing and staging pancreatic body and tail carcinoma in two patients. In the first case endoscopy, abdominal ultrasound, and computed tomography were nondiagnostic in diagnosing the origin of submucosal gastric abnormalities. Endosonography diagnosed a pancreatic tail carcinoma with submucosal gastric involvement, and this was confirmed by endosonographic-guided cytology. Fundus varices due to segmented splenic vein involvement were found. Surgery was not recommended due to the advanced disease. In the second case pancreatic body carcinoma was diagnosed by ERCP and computed tomography. Transcutaneous ultrasonographic-guided cytological puncture confirmed the diagnosis. Endosonography revealed additional information of segmental portal hypertensionmore » with fundic varices due to splenic vein involvement. Autopsy confirmed the endosonographic diagnosis. 18 refs., 5 figs.« less

  13. [Communication between nursing students and patients with Aids].

    PubMed

    de Lima, Ivana Cristina Vieira; Galvão, Marli Teresinha Gimeniz; Costa, Enia; Freitas, Julyana Gomes; Freitag, Lorita Marlena

    2011-04-01

    This study was performed with the purpose to analyze the communication between nursing students and patients with AIDS during peripheral venous puncture. Video recordings were made of six pairs (student-patient) while performing the venous puncture procedure in May 2009 at a day-hospital in Fortaleza-Ceará. As a group, four judges evaluated the interactions established between the pairs. The analyses were categorized in: Valuing technique over communication; Mask: a barriers to communication; Private space invasion; Interference of the environment in the communication. It was concluded that different factors increase the difficulty establishing an effective communication, especially the need for students to be trained about the importance of establishing communication during care, so as to promote humanized and individual care, in which sensitivity and empathy overlap fear and insecurity.

  14. Gloves against mineral oils and mechanical hazards: composites of carboxylated acrylonitrile–butadiene rubber latex

    PubMed Central

    Krzemińska, Sylwia; Rzymski, Władysław M.; Malesa, Monika; Borkowska, Urszula; Oleksy, Mariusz

    2016-01-01

    Resistance to permeation of noxious chemical substances should be accompanied by resistance to mechanical factors because the glove material may be torn, cut or punctured in the workplace. This study reports on glove materials, protecting against mineral oils and mechanical hazards, made of carboxylated acrylonitrile–butadiene rubber (XNBR) latex. The obtained materials were characterized by a very high resistance of the produced materials to oil permeation (breakthrough time > 480 min). The mechanical properties, and especially tear resistance, of the studied materials were improved after the addition of modified bentonite (nanofiller) to the XNBR latex mixture. The nanocomposite meets the requirements in terms of parameters characterizing tear, abrasion, cut and puncture resistance. Therefore, the developed material may be used for the production of multifunctional protective gloves. PMID:26757889

  15. Multiple intraosseous hemangiomas-investigation and role of N-butylcyanoacrylate in management.

    PubMed

    Syal, Rajan; Tyagi, Isha; Goyal, Amit; Barai, Sukanto; Parihar, Anit

    2007-05-01

    Primary intraosseous hemangiomas are rare (0.7% of all osseous neoplasms), benign, slow-growing neoplasms. These lesions are usually solitary. We are reporting a case of multicentric intraosseous hemangiomas. Investigation, treatment options, and role of N-butylcyanoacrylate (NBCA) in management will be discussed. A 20-year-old man had multicentric intraosseous hemangiomas involving the skull bones, mandible, vertebra, pelvic bone, and tibial tuberosity. N-butylcyanoacrylate was used by direct puncture technique using a transosseous transcutaneous route to control profuse bleeding from the retromolar region. To the best of our knowledge, this is the first reported case with such extensive multicentric intraosseous hemangiomas. N-butylcyanoacrylate by direct puncture technique can be an effective method to devascularize and stabilize low-flow intraosseous vascular tumors. (c) 2007 Wiley Periodicals, Inc.

  16. RS3PE Syndrome with Iliopsoas Bursitis Distinguished from an Iliopsoas Abscess Using a CT-guided Puncture.

    PubMed

    Fukui, Shoichi; Iwamoto, Naoki; Tsuji, Sosuke; Umeda, Masataka; Nishino, Ayako; Nakashima, Yoshikazu; Suzuki, Takahisa; Horai, Yoshiro; Koga, Tomohiro; Kawashiri, Shin-ya; Ichinose, Kunihiro; Hirai, Yasuko; Tamai, Mami; Nakamura, Hideki; Origuchi, Tomoki; Kawakami, Atsushi

    2015-01-01

    A 55-year-old man was diagnosed with remitting seronegative symmetrical synovitis with pitting edema (RS3PE) syndrome. Contrast-enhanced computed tomography for cancer screening showed a mass with low-density centers with an enhanced rim in the left iliopsoas muscle. We suspected an iliopsoas abscess and performed computed-tomography-guided puncture of the mass. Both Gram staining and the culture of the fluid were negative. We diagnosed the patient with RS3PE syndrome with iliopsoas bursitis and administered low-dose corticosteroids without antibiotics. The symptoms, including left hip pain, quickly disappeared following treatment. Clinicians should be aware that iliopsoas bursitis may resemble an iliopsoas abscess. As a result, it is important to make an accurate differential diagnosis.

  17. Tire with Self-Repairing Mechanism

    NASA Astrophysics Data System (ADS)

    Nagaya, Kosuke; Ikai, Sigeo; Chiba, Manabu; Chao, Xujing

    A new type of tire is presented, in which there is no air leakage when nails puncture the tire. The broken part is repaired automatically by a self-repairing mechanism. The self-repairing unit consists of two rubber sheets with internal lattices. Polymer particles, which expand their volume on adding water, are inserted into the lattices. The unit is adhered to the inside wall of the tire. Coolant fluid diluted with water is introduced to the polymers uniformly. In this system, the polymer particles expand with water-diluted coolant fluid, and become gel. Hence, they stop air leakages in the tire. Fundamental experiments are performed, and optimum conditions are found. This technique is also applied to real tires, and it is ascertained that there is no air leakage when the tire is punctured by nails.

  18. Vascular trauma and prostacyclin release.

    PubMed

    Jeremy, J Y; Mikhailidis, D P; Dandona, P

    1984-10-01

    The effect of trauma on prostacyclin (PGI2) secretion by rat aorta was examined. Whereas cutting and puncturing markedly increased PGI2 secretion, sonication and stretch had no effect. Cutting and puncturing were also effective in stimulating further endogenous secretion of PGI2 from 'exhausted' aortic segments in whom PGI2 production had dwindled to a negligible rate. These experiments show that trauma is an important stimulator of PGI2 secretion, the exhaustion of PGI2 secretion by vascular segments is not due to the depletion of substrate (arachidonic acid) and that an unusually traumatic venepuncture may invalidate the subsequent assays of PGI2 and its stable metabolite, 6-oxo-PGF1 alpha, in plasma. The close relationship of vascular trauma to PGI2 release also suggests a possible cytoprotective effect of this prostanoid on vascular endothelium.

  19. Puncturing the pipeline: Do technology companies alienate women in recruiting sessions?

    PubMed

    Wynn, Alison T; Correll, Shelley J

    2018-02-01

    A 'chilly' environment limits women's advancement through the educational pipeline leading to jobs in science and technology. However, we know relatively little about the environment women encounter after making it through the educational pipeline. Do technology companies create environments that may dampen women's interest at the juncture when they are launching their careers? Using original observational data from 84 recruiting sessions hosted by technology companies at a prominent university on the US West Coast, we find that company representatives often engage in behaviors that are known to create a chilly environment for women. Through gender-imbalanced presenter roles, geek culture references, overt use of gender stereotypes, and other gendered speech and actions, representatives may puncture the pipeline, lessening the interest of women at the point of recruitment into technology careers.

  20. Lower Learning Difficulty and Fluoroscopy Reduction of Transforaminal Percutaneous Endoscopic Lumbar Discectomy with an Accurate Preoperative Location Method.

    PubMed

    Fan, Guoxin; Gu, Xin; Liu, Yifan; Wu, Xinbo; Zhang, Hailong; Gu, Guangfei; Guan, Xiaofei; He, Shisheng

    2016-01-01

    Transforaminal percutaneous endoscopic lumbar discectomy (tPELD) poses great challenges for junior surgeons. Beginners often require repeated attempts using fluoroscopy causing more punctures, which may significantly undermine their confidence and increase the radiation exposure to medical staff and patients. Moreover, the impact of an accurate location on the learning curve of tPELD has not been defined. The study aimed to investigate the impact of an accurate preoperative location method on learning difficulty and fluoroscopy time of tPELD. Retrospective evaluation. Patients receiving tPELD by one surgeon with a novel accurate preoperative location method were regarded as Group A, and those receiving tPELD by another surgeon with a conventional fluoroscopy method were regarded as Group B. From January 2012 to August 2014, we retrospectively reviewed the first 80 tPELD cases conducted by 2 junior surgeons. The operation time, fluoroscopy times, preoperative location time, and puncture-channel time were thoroughly analyzed. The operation time of the first 20 patients were 99.75 ± 10.38 minutes in Group A and 115.7 ± 16.46 minutes in Group B, while the operation time of all 80 patients was 88.36 ± 11.56 minutes in Group A and 98.26 ± 14.90 minutes in Group B. Significant differences were detected in operation time between the 2 groups, both for the first 20 patients and total 80 patients (P < 0.05). The fluoroscopy times were 26.78 ± 4.17 in Group A and 33.98 ± 2.69 in Group B (P < 0.001). The preoperative location time was 3.43 ± 0.61 minutes in Group A and 5.59 ± 1.46 minutes in Group B (P < 0.001). The puncture-channel time was 27.20 ± 4.49 minutes in Group A and 34.64 ± 8.35 minutes in Group B (P < 0.001). There was a moderate correlation between preoperative location time and puncture-channel time (r = 0.408, P < 0.001), and a moderate correlation between preoperative location time and fluoroscopy times (r = 0.441, P < 0.001). Mild correlations were also observed between preoperative location time and operation time (r = 0.270, P = 0.001). There were no significant differences in preoperative back visual analogue scale (VAS) score, postoperative back VAS, preoperative leg VAS, postoperative leg VAS, preoperative Japanese Orthopaedic Association (JOA) score, postoperative JOA, preoperative Oswestry disability score (ODI), or postoperative ODI (P > 0.05). However, significant differences were all detected between preoperative abovementioned scores and postoperative scores (P < 0.05). Moreover, there was no significant differences in Macnab satisfaction between the 2 groups (P = 0.179). There were 2 patients with recurrence in Group A and 3 patients in Group B. Twelve patients with postoperative disc remnants were identified in Group A and 9 patients in Group B. No significant difference was identified between the 2 groups (P = 0.718). The preoperative lumbar location method is just a tiny step in tPELD, junior surgeons still need to focus on their subjective feelings during punctures and accumulating their experience in endoscopic discectomy. The accurate preoperative location method lowered the learning difficulty and reduced the fluoroscopy time of tPELD, which was also associated with lower preoperative location time and puncture-channel time. Key words: Learning difficulty, fluoroscopy reduction, transforamimal percutaneous endoscopic lumbar discectomy, preoperative locationLearning difficulty, fluoroscopy reduction, transforamimal percutaneous endoscopic lumbar discectomy, preoperative location.

  1. Blood optical properties at various glucose level values in THz frequency range

    NASA Astrophysics Data System (ADS)

    Gusev, S. I.; Borovkova, M. A.; Strepitov, M. A.; Khodzitsky, M. K.

    2015-07-01

    The number of diabetics is rapidly growing every day in all parts of the world. By the year 2010, the number of patients suffering from diabetes had amounted to more than 230 million people, which is estimated as 3.5% of the whole world adult population [1]. According to expert forecasts, this number is projected to double by the year 2025, which is going to be 7% of whole Earth population. It was calculated that every 10 seconds someone in the world dies due to diabetes and its complications, which is 3 million people per year. The average life expectancy of children with diabetes is less than 28.3 years of onset. Diabetes is considered to be the fourth most common cause of death in industrialized countries. Vascular complications due to diabetes cause early disability and high mortality. Mortality from heart diseases and strokes is 2-3 times more likely for patients suffering from diabetes, whereas blindness, nephropathy and lower limbs gangrene happen respectively 10, 12-15 times, and almost 20 times more often for diabetics than general population. The number and strength of complications depend directly on the blood glucose level control quality. At the moment, the blood glucose level measurements are performed by glucometers [2,3]. This method requires that a patient makes a finger puncture for every measurement. About five punctures per day should be done for proper glucose monitoring, which is about 1,800 punctures per year. Besides, each measurement by glucometer requires a distinct test strip. Expenses for 1,800 test strips could be estimated as about 450 euros per year. It is also necessary to take into account that each puncture has a risk of blood poisoning. Using non-invasive techniques for glucose level control could reduce the amount of possible risky manipulations by 1800 per year. Moreover, it is worth mentioning that only eight of ten fingers are suitable for puncturing, and the constant skin damage which cannot be avoided is quite annoying for the patients. Most biomolecules have characteristic signature frequencies in the terahertz (THz) range, which can reveal their presence and determine the concentration. Therefore, this paper is intended to study the blood optical properties in the THz frequency range in order to determine THz radiation effect on blood. The main aim of this investigation is to determine the effect of blood glucose concentration on the blood optical properties. In the case if blood optical properties vary at different glucose concentrations having a proportional relationship between them, these results will confirm the possibility of development of non-invasive procedures for blood glucose level diagnostics.

  2. Adult Foot Health

    MedlinePlus

    ... puncture wounds can also result in painful sores. Dark brown or black warts can indicate a type ... protect feet and avoid injury. Any injury, no matter how minor, deserves careful attention. You also must ...

  3. Emergency airway puncture - series (image)

    MedlinePlus

    ... passes to the lungs. The thryoid and cricoid cartilage form the narrowest section of this airway. ... the larynx bounded by the thyroid and cricoid cartilage is a frequent site for obstruction, either by ...

  4. 21 CFR 524.1580b - Nitrofurazone ointment.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... prevention or treatment of surface bacterial infections of wounds, burns, and cutaneous ulcers of dogs, cats... deep or puncture wounds or serious burns, use only as recommended by veterinarian. If redness...

  5. Cuts and puncture wounds

    MedlinePlus

    ... pointed object such as a nail, knife, or sharp tooth. Symptoms Symptoms include: Bleeding Problems with function ... the last 10 years. Prevention Keep knives, scissors, sharp objects, firearms, and fragile items out of the ...

  6. Improving patient safety during insertion of peripheral venous catheters: an observational intervention study.

    PubMed

    Kampf, Günter; Reise, Gesche; James, Claudia; Gittelbauer, Kirsten; Gosch, Jutta; Alpers, Birgit

    2013-01-01

    Peripheral venous catheters are frequently used in hospitalized patients but increase the risk of nosocomial bloodstream infection. Evidence-based guidelines describe specific steps that are known to reduce infection risk. However, the degree of guideline implementation in clinical practice is not known. The aim of this study was to determine the use of specific steps for insertion of peripheral venous catheters in clinical practice and to implement a multimodal intervention aimed at improving both compliance and the optimum order of the steps. The study was conducted at University Hospital Hamburg. An optimum procedure for inserting a peripheral venous catheter was defined based on three evidence-based guidelines (WHO, CDC, RKI) including five steps with 1A or 1B level of evidence: hand disinfection before patient contact, skin antisepsis of the puncture site, no palpation of treated puncture site, hand disinfection before aseptic procedure, and sterile dressing on the puncture site. A research nurse observed and recorded procedures for peripheral venous catheter insertion for healthcare workers in four different departments (endoscopy, central emergency admissions, pediatrics, and dermatology). A multimodal intervention with 5 elements was established (teaching session, dummy training, e-learning tool, tablet and poster, and direct feedback), followed by a second observation period. During the last observation week, participants evaluated the intervention. In the control period, 207 insertions were observed, and 202 in the intervention period. Compliance improved significantly for four of five steps (e.g., from 11.6% to 57.9% for hand disinfection before patient contact; p<0.001, chi-square test). Compliance with skin antisepsis of the puncture site was high before and after intervention (99.5% before and 99.0% after). Performance of specific steps in the correct order also improved (e.g., from 7.7% to 68.6% when three of five steps were done; p<0.001). The intervention was described as helpful by 46.8% of the participants, as neutral by 46.8%, and as disruptive by 6.4%. A multimodal strategy to improve both compliance with safety steps for peripheral venous catheter insertion and performance of an optimum procedure was effective and was regarded helpful by healthcare workers.

  7. A Novel Modality for Functional Imaging in Acute Intervertebral Disk Herniation via Tracking Leukocyte Infiltration.

    PubMed

    Xiao, Li; Ding, Mengmeng; Zhang, Yi; Chordia, Mahendra; Pan, Dongfeng; Shimer, Adam; Shen, Francis; Glover, David; Jin, Li; Li, Xudong

    2017-10-01

    Inflammation plays a key role in the progression of intervertebral disk (IVD) herniation and associated low back pain. However, real-time spatial diagnosis of inflammation associated with acute disk herniation has not been investigated. We sought to detect local neutrophil and macrophage infiltration near disk herniation via the formyl peptide receptor 1 (FPR1)-mediated molecular imaging in a disk puncture mouse model to elucidate pathophysiological process of disk herniation. Disk herniation was induced in mouse with an established needle puncture procedure. Degenerative change of disk and infiltration of neutrophils and macrophages were detected with Safranin-O, hematoxylin and eosin (H&E), and immunohistochemical staining after injury. FPR1-specific imaging probes cFLFLF-PEG-Cy7 and [ 99m Tc]HYNIC-PEG-cFLFLF were administered systemically to sham and disk injury mice. Leukocyte infiltration was tracked by in vivo near-infrared fluorescence (NIRF) and single-photon emission tomography (SPECT) imaging. The peptide-receptor binding specificity was further investigated with FPR1 -/- mice via ex vivo NIRF scan and in vitro binding assays. Safranin-O staining exhibited disorganized disk structure and loss of proteoglycan after puncture. Massive inflammatory cells were observed in the anterior region of punctured annulus in the injury group. The majority of neutrophils were detected at 1 through 3 days, while infiltration of macrophages appeared the most at 7 days after injury. NIRF and SPECT images revealed preferential accumulation of cFLFLF probes in herniation site in wild-type mice but not in FPR1 -/- mice. Binding of the cFLFLF peptide to FPR1 was also observed in RAW 267.4 cells and macrophages isolated from wild-type mice, whereas much less signal was observed in macrophages from FPR1 -/- mice. The presence of macrophage infiltration was also detected in human-herniated disk samples by immunohistochemistry. For the first time, leukocyte infiltration around acute disk herniation site was detected directly and non-invasively in a timely fashion using FPR1-targeted molecular imaging modalities. Such functional imaging of disk herniation via infiltrated leukocytes would advance the understanding of etiology and facilitate drug delivery and treatment monitoring of disk herniation.

  8. Cerebral mechanism of puncturing at He-Mu point combination for functional dyspepsia: study protocol for a randomized controlled parallel trial.

    PubMed

    Yin, Shuai; Chen, Yuan; Lei, Du; Sun, Rui-Rui; Ma, Ting-Ting; Feng, Pei-Min; He, Zhao-Xuan; Suo, Xue-Ling; Ma, Pei-Hong; Qu, Yu-Zhu; Qiu, Ke; Jing, Miao-Miao; Gong, Qi-Yong; Liang, Fan-Rong; Chen, Jiao; Zeng, Fang

    2017-05-01

    Acupuncture is widely used to treat functional dyspepsia with satisfactory outcomes. Combination of the He and Mu acupoints is commonly used and has a synergistic effect on functional dyspepsia; however, its underlying mechanisms remain unclear. Therefore, a randomized controlled parallel clinical trial is currently underway at Chengdu University of Traditional Chinese Medicine, China. This trial is designed to explore the efficacy of and central responses to the He-Mu point combination in patients with functional dyspepsia using functional magnetic resonance imaging. A total of 105 patients with functional dyspepsia will be allocated into 3 groups: the low-He point group (puncturing at Zusanli (ST36)), Mu point group (puncturing at Zhongwan (CV12)), and He-Mu point combination group (puncturing at ST36 and CV12). Every participant will receive 20 sessions of manual acupuncture for 4 weeks. The needles will be inserted perpendicularly to a depth of 1 to 2 cun. The angle of rotation and twisting will range from 90 to 180 degrees, while lifting and thrusting will range from 0.3 to 0.5 cm. The various manipulations will be performed 60 to 90 times per minute. The needles will remain in place for 30 minutes, during which manipulation will be applied every 10 minutes. Magnetic resonance imaging will be performed before and after 20 sessions of acupuncture. The primary outcome is symptom improvement according to the Chinese version of the Nepean Dyspepsia Index. Secondary outcomes include the Leeds dyspepsia questionnaire, Self-Rating Anxiety Scale, Self-Rating Depression Scale, Beck Anxiety Inventory, Beck Depression Inventory, and visual analogue scale scores before and after 10 and 20 sessions of acupuncture. Needle sensation and adverse events will be used to assess the therapeutic effects. This study will promote more widespread awareness of the benefits of acupoint combination in the clinical setting and provide a further explanation of the neuromechanism by which acupuncture at the He-Mu point combination for functional dyspepsia. Registration: Chinese Clinical Trial Registry, ChiCTR-IOR-15006402.

  9. The 'pit-crew' model for improving door-to-needle times in endovascular stroke therapy: a Six-Sigma project.

    PubMed

    Rai, Ansaar T; Smith, Matthew S; Boo, SoHyun; Tarabishy, Abdul R; Hobbs, Gerald R; Carpenter, Jeffrey S

    2016-05-01

    Delays in delivering endovascular stroke therapy adversely affect outcomes. Time-sensitive treatments such as stroke interventions benefit from methodically developed protocols. Clearly defined roles in these protocols allow for parallel processing of tasks, resulting in consistent delivery of care. To present the outcomes of a quality-improvement (QI) process directed at reducing stroke treatment times in a tertiary level academic medical center. A Six-Sigma-based QI process was developed over a 3-month period. After an initial analysis, procedures were implemented and fine-tuned to identify and address rate-limiting steps in the endovascular care pathway. Prospectively recorded treatment times were then compared in two groups of patients who were treated 'before' (n=64) or 'after' (n=30) the QI process. Three time intervals were measured: emergency room (ER) to arrival for CT scan (ER-CT), CT scan to interventional laboratory arrival (CT-Lab), and interventional laboratory arrival to groin puncture (Lab-puncture). The ER-CT time was 40 (±29) min in the 'before' and 26 (±15) min in the 'after' group (p=0.008). The CT-Lab time was 87 (±47) min in the 'before' and 51 (±33) min in the 'after' group (p=0.0002). The Lab-puncture time was 24 (±11) min in the 'before' and 15 (±4) min in the 'after' group (p<0.0001). The overall ER-arrival to groin-puncture time was reduced from 2 h, 31 min (±51) min in the 'before' to 1 h, 33 min (±37) min in the 'after' group, (p<0.0001). The improved times were seen for both working hours and off-hours interventions. A protocol-driven process can significantly improve efficiency of care in time-sensitive stroke interventions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Fractures

    MedlinePlus

    A fracture is a break, usually in a bone. If the broken bone punctures the skin, it is called an open ... falls, or sports injuries. Other causes are low bone density and osteoporosis, which cause weakening of the ...

  11. Ovarian dermoid cyst leakage--a cautionary tale.

    PubMed

    Edwards, A G; Lawrence, A; Tsaltas, J

    1998-08-01

    This case illustrates that when a dermoid cyst is punctured, an immediate operative laparoscopy or laparotomy should be performed, along with lavage, to avoid the problems associated with dermoid cyst contents spillage.

  12. NASA Research Announcement for Space Suit Survivability Enhancement

    NASA Technical Reports Server (NTRS)

    Fredrickson, Thad H.; Ware, Joanne S.; Lin, John K.; Pastore, Christopher M.

    1998-01-01

    This report documents the research activities for space suit survivability material enhancements. Self-sealing mechanisms for the pressure envelope were addressed, as were improvements in materials for cut, puncture, and hypervelocity impact resistance.

  13. Childhood Ependymoma Treatment

    MedlinePlus

    ... a neuro exam or a neurologic exam. MRI (magnetic resonance imaging) with gadolinium : A procedure that uses a magnet, ... the picture. This procedure is also called nuclear magnetic resonance imaging (NMRI). Lumbar puncture : A procedure used to collect ...

  14. Safety Tips.

    ERIC Educational Resources Information Center

    Nagel, Miriam C., Ed.

    1984-01-01

    Outlines a cooperative effort in Iowa to eliminate dangerous or unwanted chemicals from school science storerooms. Also reviews the Council of State Science Supervisor's safety program and discusses how to prevent cuts and punctures from jagged glass tubing. (JN)

  15. Lumbar puncture (image)

    MedlinePlus

    ... is a clear fluid that circulates in the space surrounding the spinal cord and brain. CSF protects the brain and spinal cord from injury by acting like a liquid cushion. CSF is usually obtained through a lumbar ...

  16. Stent-Grafts in the Management of Hemorrhagic Complications Related to Hemostatic Closure Devices: Report of Two Cases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giansante Abud, Daniel; Mounayer, Charbel; Saint-Maurice, Jean Pierre

    We report 2 cases of hemorrhagic complications related to use of the Angio-Seal hemostatic closure device that were successfully managed with stent-grafts. Two patients with subarachnoid hemorrhage were referred to our departments for endovascular treatment of ruptured intracranial aneurysms. The treatment was performed through a femoral access; the sheaths were removed immediately after the procedures, and the punctures sites closed by Angio-Seals. Both patients presented clinical signs of hypovolemic shock after treatment. The diagnosis of active bleeding through the puncture site was made by emergency digital subtraction angiography. The lesions were managed with stent-grafts. The use of stent-grafts proved tomore » be efficient in the management of these life-threatening hemorrhagic complications following the use of the Angio-Seal hemostatic closure device.« less

  17. Retrograde intubation: an alternative way for the management of difficult airway.

    PubMed

    Lama, P; Shrestha, B R

    2008-01-01

    Inserting a retrograde wire into the pharynx through a cricothyroid puncture can facilitate tracheal intubation in difficult situations where either a flexible fiber-optic bronchoscope or an expert user of such a device is not available. Even in cases when fibropric can not be negotiated for the purpose, this method has been claimed to be useful to manage the airway. Some mouth opening is essential for the oral or nasal retrieval of the wire from the pharynx. Here, a case of post mandibular reconstructed wound infection required surgical debridement and plate removal from reconstructed lower mandible under general anesthesia. We retrieved the guide wire passed through a cricothyroid puncture and subsequently accomplished wire-guided oro-tracheal intubation. In the absence of a flexible fiber-optic bronchoscope, this technique is a very useful aid to intubate patients with limited mouth opening.

  18. [Minimally invasive approach for cervical spondylotic radiculopathy].

    PubMed

    Ding, Liang; Sun, Taicun; Huang, Yonghui

    2010-01-01

    To summarize the recent minimally invasive approach for cervical spondylotic radiculopathy (CSR). The recent literature at home and abroad concerning minimally invasive approach for CSR was reviewed and summarized. There were two techniques of minimally invasive approach for CSR at present: percutaneous puncture techniques and endoscopic techniques. The degenerate intervertebral disc was resected or nucleolysis by percutaneous puncture technique if CSR was caused by mild or moderate intervertebral disc herniations. The cervical microendoscopic discectomy and foraminotomy was an effective minimally invasive approach which could provide a clear view. The endoscopy techniques were suitable to treat CSR caused by foraminal osteophytes, lateral disc herniations, local ligamentum flavum thickening and spondylotic foraminal stenosis. The minimally invasive procedure has the advantages of simple handling, minimally invasive and low incidence of complications. But the scope of indications is relatively narrow at present.

  19. Minimal adverse effects profile following implantation of periauricular percutaneous electrical nerve field stimulators: a retrospective cohort study

    PubMed Central

    Roberts, Arthur; Sithole, Alec; Sedghi, Marcos; Walker, Charles A; Quinn, Theresa M

    2016-01-01

    The periauricular percutaneous implantation of the Neuro-Stim System™ family of devices EAD, MFS, and BRIDGE is a procedure involving the use of a non-opiate, neuromodulation analgesic for relieving acute and chronic pain. It has been approved as a minimal-risk procedure by multiple governmental and institutional facilities. This retrospective report of findings will help quantify the incidence of clinically observed bleeding, localized dermatitis, and infections at the implantation sites of the electrode/needle arrays, dermatitis at the site of the generator, and patient syncope. A total of 1,207 devices, each producing up to 16 percutaneous punctures, for a total of 19,312 punctures were monitored for adverse effects, based on retrospective chart audits conducted at six clinical facilities over a 1-year period. PMID:27843360

  20. Ballistic Puncture Self-Healing Polymeric Materials

    NASA Technical Reports Server (NTRS)

    Gordon, Keith L.; Siochi, Emilie J.; Yost, William T.; Bogert, Phil B.; Howell, Patricia A.; Cramer, K. Elliott; Burke, Eric R.

    2017-01-01

    Space exploration launch costs on the order of $10,000 per pound provide an incentive to seek ways to reduce structural mass while maintaining structural function to assure safety and reliability. Damage-tolerant structural systems provide a route to avoiding weight penalty while enhancing vehicle safety and reliability. Self-healing polymers capable of spontaneous puncture repair show promise to mitigate potentially catastrophic damage from events such as micrometeoroid penetration. Effective self-repair requires these materials to quickly heal following projectile penetration while retaining some structural function during the healing processes. Although there are materials known to possess this capability, they are typically not considered for structural applications. Current efforts use inexpensive experimental methods to inflict damage, after which analytical procedures are identified to verify that function is restored. Two candidate self-healing polymer materials for structural engineering systems are used to test these experimental methods.

  1. Spectrophotometry of cerebrospinal fluid in subacute and chronic subdural haematomas

    PubMed Central

    Kjellin, K. G.; Steiner, L.

    1974-01-01

    Spectrophotometric examinations were performed on cerebrospinal and subdural fluids in subacute (five patients) and chronic (20 patients) subdural haematomas, with special reference to the diagnostic aid of CSF spectrophotometry. Spectrophotometric xanthochromia of haemorrhagic origin was found in all CSFs examined, while definite visible xanthochromia was observed in only 28% and the CSF was judged as colourless in 52% of those cases. Characteristic bleeding patterns were found spectrophotometrically in all the 20 CSFs examined within 24 hours after lumbar puncture, haematoma patterns being detected in 90-95% of the cases. In many cases the electrophoretically separated protein fractions of CSF and subdural fluids were spectrophotometrically examined. In conclusion, CSF spectrophotometry is a simple, fast, and extremely sensitive method, which in our opinion should be used routinely in the diagnosis of suspected subdural haematomas, if lumbar puncture is not contraindicated. PMID:4140892

  2. Hybrid Black-Hole Binary Initial Data

    NASA Technical Reports Server (NTRS)

    Mundim, Bruno C.; Kelly, Bernard J.; Nakano, Hiroyuki; Zlochower, Yosef; Campanelli, Manuela

    2010-01-01

    "Traditional black-hole binary puncture initial data is conformally flat. This unphysical assumption is coupled with a lack of radiation signature from the binary's past life. As a result, waveforms extracted from evolutions of this data display an abrupt jump. In Kelly et al. [Class. Quantum Grav. 27:114005 (2010)], a new binary black-hole initial data with radiation contents derived in the post-Newtonian (PN) calculations was adapted to puncture evolutions in numerical relativity. This data satisfies the constraint equations to the 2.5PN order, and contains a transverse-traceless "wavy" metric contribution, violating the standard assumption of conformal flatness. Although the evolution contained less spurious radiation, there were undesired features; the unphysical horizon mass loss and the large initial orbital eccentricity. Introducing a hybrid approach to the initial data evaluation, we significantly reduce these undesired features."

  3. Day surgery for vocal fold lesions using a double-bent 60-mm Cathelin needle.

    PubMed

    Toyomura, Fumimasa; Tokashiki, Ryoji; Hiramatsu, Hiroyuki; Tsukahara, Kiyoaki; Motohashi, Ray; Sakurai, Eriko; Nomoto, Masaki; Suzuki, Mamoru

    2014-11-01

    Day surgery for vocal cord lesions overcomes the disadvantages of laryngomicrosurgery under general anesthesia. We present our experience with treatment of vocal fold lesions using a long double-bend Cathelin needle that can access all parts of the vocal cords. A 23G, 60-mm-long Cathelin needle was bent twice by 45(o) at a distance of 1 and 2 cm from the tip, and was attached to a syringe. Under topical anesthesia and nasal endoscopy of the laryngopharynx, the needle was inserted percutaneously perpendicular to the skin, the direction of insertion being altered when the bends in the needle reached the skin surface. This allows the tip of the needle to access all parts of the glottis, allowing the performance of procedures such as biopsies, excision of lesions, and injection into the vocal folds. Between January 2011 and December 2013, we used this technique to perform vocal fold procedures in 566 patients presenting for treatment of spasmodic dysphonia (412 cases, 73 %) and other vocal fold lesions. Only minor complications, such as hematoma (3 patients, 0.5 %) and slight bleeding from the puncture site in the epiglottic vallecula (all patients, 100 %), which ceased spontaneously within 10 min, were seen. Erroneous puncture occurred in three patients (0.5 %) and the puncture had to be repeated in 38 patients (6.7 %). The procedure was completed successfully in all cases (100 %). Surgery for vocal fold lesions under topical anesthesia using our double-bend Cathelin needle technique is simple, safe, and useful.

  4. Oocyte recovery by ovum pick up and embryo production in river buffaloes (Bubalus bubalis).

    PubMed

    Manjunatha, B M; Ravindra, J P; Gupta, P S P; Devaraj, M; Nandi, S

    2008-08-01

    Ovum pick up (OPU) was conducted twice a week for 12 weeks in six cycling, non-descriptive (local breed), Indian buffaloes to study the efficiency of OPU on recovery of oocytes for embryo production. OPU was performed using an ultrasound equipment with a 5-MHz transvaginal transducer, a single-lumen, 18-gauge, 55-cm-long needle and a constant vacuum pressure of 110 mmHg. The number and size of follicles were determined before puncture. The recovered oocytes were graded, washed, matured for 24 h and then fertilized with frozen-thawed semen, followed by embryo culture on the oviductal monolayer. The mean number of follicles observed per animal per session did not differ between animals or between puncture sessions. A mean number of 3.62 +/- 0.32 mm follicles were observed, 2.90 +/- 0.15 mm follicles were punctured and 1.21 +/- 0.07 oocytes were recovered per animal per session, with an average recovery rate of 42%. Of the total oocytes recovered, 64% were suitable for in vitro embryo production (grade A + B) whereas 36% were classified to be of grades C + D. A mean number of 0.25 +/- 0.2 transferable embryos was produced in vitro per buffalo per session with a transferable embryo production rate of 32%. In conclusion, this study demonstrated that twice-a-week OPU could be applied repeatedly, without any adverse effects on the follicular growth and oocyte recovery and that recovered oocytes could be used for in vitro embryo production in buffaloes.

  5. Micro packaged MEMS pressure sensor for intracranial pressure measurement

    NASA Astrophysics Data System (ADS)

    Xiong, Liu; Yan, Yao; Jiahao, Ma; Yanhang, Zhang; Qian, Wang; Zhaohua, Zhang; Tianling, Ren

    2015-06-01

    This paper presents a micro packaged MEMS pressure sensor for intracranial pressure measurement which belongs to BioMEMS. It can be used in lumbar puncture surgery to measure intracranial pressure. Miniaturization is key for lumbar puncture surgery because the sensor must be small enough to allow it be placed in the reagent chamber of the lumbar puncture needle. The size of the sensor is decided by the size of the sensor chip and package. Our sensor chip is based on silicon piezoresistive effect and the size is 400 × 400 μm2. It is much smaller than the reported polymer intracranial pressure sensors such as liquid crystal polymer sensors. In terms of package, the traditional dual in-line package obviously could not match the size need, the minimal size of recently reported MEMS-based intracranial pressure sensors after packaging is 10 × 10 mm2. In this work, we are the first to introduce a quad flat no-lead package as the package form of piezoresistive intracranial pressure sensors, the whole size of the sensor is minimized to only 3 × 3 mm2. Considering the liquid measurement environment, the sensor is gummed and waterproof performance is tested; the sensitivity of the sensor is 0.9 × 10-2 mV/kPa. Project supported by the National Natural Science Foundation of China (Nos. 61025021, 61434001), and the ‘Thousands Talents’ Program for Pioneer Researchers and Its Innovation Team, China.

  6. Transatrial Intrapericardial Tricuspid Annuloplasty

    PubMed Central

    Rogers, Toby; Ratnayaka, Kanishka; Sonmez, Merdim; Franson, Dominique N.; Schenke, William H.; Mazal, Jonathan R.; Kocaturk, Ozgur; Chen, Marcus Y.; Faranesh, Anthony Z.; Lederman, Robert J.

    2015-01-01

    OBJECTIVES This study sought to demonstrate transcatheter deployment of a circumferential device within the pericardial space to modify tricuspid annular dimensions interactively and to reduce functional tricuspid regurgitation (TR) in swine. BACKGROUND Functional TR is common and is associated with increased morbidity and mortality. There are no reported transcatheter tricuspid valve repairs. We describe a transcatheter extracardiac tricuspid annuloplasty device positioned in the pericardial space and delivered by puncture through the right atrial appendage. We demonstrate acute and chronic feasibility in swine. METHODS Transatrial intrapericardial tricuspid annuloplasty (TRAIPTA) was performed in 16 Yorkshire swine, including 4 with functional TR. Invasive hemodynamics and cardiac magnetic resonance imaging (MRI) were performed at baseline, immediately after annuloplasty and at follow-up. RESULTS Pericardial access via a right atrial appendage puncture was uncomplicated. In 9 naïve animals, tricuspid septal-lateral and anteroposterior dimensions, the annular area and perimeter, were reduced by 49%, 31%, 59%, and 24% (p < 0.001), respectively. Tricuspid leaflet coaptation length was increased by 53% (p < 0.001). Tricuspid geometric changes were maintained after 9.7 days (range, 7 to 14 days). Small effusions (mean, 46 ml) were observed immediately post-procedure but resolved completely at follow-up. In 4 animals with functional TR, severity of regurgitation by intracardiac echocardiography was reduced. CONCLUSIONS Transatrial intrapericardial tricuspid annuloplasty is a transcatheter extracardiac tricuspid valve repair performed by exiting the heart from within via a transatrial puncture. The geometry of the tricuspid annulus can interactively be modified to reduce severity of functional TR in an animal model. PMID:25703872

  7. Percutaneous suprapubic stone extraction for posterior urethral stones in children: efficacy and safety.

    PubMed

    Safwat, Ahmed S; Hameed, Diaa A; Elgammal, Mohamed A; Abdelsalam, Yasser M; Abolyosr, Ahmad

    2013-08-01

    To evaluate the safety and efficacy of percutaneous suprapubic stone extraction (PSPSE) for pediatric posterior urethral stones. Between July 2007 and June 2010, 54 boys presenting with acute urinary retention due to posterior urethral stones underwent PSPSE. Patients were a mean age of 66.4 months (range, 8-180 months). The stone size was 0.7-1.9 cm. Patients were placed under general anesthesia, and a 7F urethroscope was used to pushback the stone to the bladder. A 3-mm suprapubic puncture with a scalpel was performed, followed by insertion of a straight narrow hemostat through the puncture aided with cystoscopic guidance. The stone was grasped with the hemostat in its narrowest diameter and was extracted percutaneously or crushed if friable. The suprapubic puncture was closed with a single 4-0 Vicryl (Ethicon) suture. Intact stone retrieval was achieved in 45 patients, and the stone was crushed into minute fragments in 9 patients. Intraperitoneal extravasation developed in 1 patient that required open surgical intervention. Mean operative time was 22 minutes. Patients were monitored for up to 17 months, with complete resolution of symptoms and stone clearance. PSPSE provides a minimally invasive approach for the extraction of urethral and bladder stones in the pediatric population. The use of a straight hemostat for suprapubic stone extraction or crushing is a good alternative to suprapubic tract dilation, with minimal morbidity. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Subarachnoid and basal cistern navigation through the sacral hiatus with guide wire assistance.

    PubMed

    Layer, Lauren; Riascos, Roy; Firouzbakht, Farhood; Amole, Adewumi; Von Ritschl, Rudiger; Dipatre, Pier; Cuellar, Hugo

    2011-07-01

    Intraspinal navigation with catheters and fiberscopes has shown feasible results for diagnosis and treatment of intraspinal and intracranial lesions. The most common approach, lumbar puncture, has allowed access to the spinal cord, however, coming with the difficulties of fiberscope damage and decreased torque for guidance. Our objective in this study is to allow an alternate access, the sacral hiatus, with guide wire assistance into the subarachnoid and intracranial structures, while easing the angle of entry and increasing torque. We advanced catheters with guide wire and fluoroscopy assistance into the sacral hiatus of three cadavers. After entry, the thecal sac was punctured and the catheter with guide wire was advanced rostrally until positioned in the basal cisterns of the brain. We confirmed catheter placement with contrast injection, autopsy, and dissection. In our study, the sacral hiatus was easily accessed, but resistance was found when attempting to puncture the thecal sac. The advancement of the catheter with guide wire assistance glided easily rostrally until some mild resistance was discovered at entry into the foramen magnum. With redirection, all catheters passed with ease into the basal cisterns. Positioning was confirmed with contrast injection with fluoroscopy evidence, autopsy, and dissection. There was no macroscopic or microscopic evidence of damage to the spinal roots, spinal cord, or cranial nerves. The sacral hiatus with guide wire assistance is an accessible conduit for uncomplicated entry into the subarachnoid and basal cistern space without damaging surrounding structures.

  9. The intraoperative use of ultrasound facilitates significantly the arthroscopic debridement of calcific rotator cuff tendinitis.

    PubMed

    Sabeti, M; Schmidt, M; Ziai, P; Graf, A; Nemecek, E; Schueller-Weidekamm, C

    2014-05-01

    During arthroscopy, the localization of calcific deposit in patients suffering from calcifying tendinitis can be demanding and time consuming, frequently using ionizing radiation. Intraoperative ultrasound has been recently promoted, facilitating deposit localization and reducing radiation dose. In this prospective, randomized, controlled and clinical observer-blinded pilot trial, 20 patients with calcific tendinitis were operated. In group I, the deposit was localized conventionally. In group II, the deposit was localized using intraoperative ultrasound. The needle punctures to detect the deposit and operation times were noted. Patients were postoperatively evaluated after 2 and 6 weeks and 9 months. In group II, the needle punctures to detect the deposit were significantly lower than in group I (p < 0.0001). Operation time to localize the deposit was also significantly less in group II (p < 0.033). In both groups, patients improved significantly with increased shoulder function (p < 0.0001) and decreased pain (p < 0.0001) 2 weeks and 9 months (p < 0.001) after surgery. The difference between the groups was not significant. Excellent radiological findings were obtained in both groups after 9 months. Intraoperative US significantly facilitates the detection of calcific deposits during arthroscopic debridement by speeding up surgery and reducing the number of needle punctures. Hence, we have changed our method of detecting calcific deposits intraoperatively from fluoroscopy to ultrasound.

  10. The learning curve for access creation in solo ultrasonography-guided percutaneous nephrolithotomy and the associated skills.

    PubMed

    Yu, Weimin; Rao, Ting; Li, Xing; Ruan, Yuan; Yuan, Run; Li, Chenglong; Li, Haoyong; Cheng, Fan

    2017-03-01

    The aim of the current trial was to evaluate the learning curve of access creation through solo ultrasonography (US)-guided percutaneous nephrolithotomy (PCNL), and clarify the technical details of the procedure. We evaluated the first 240 solo US-guided PCNLs performed by one surgeon at our institution. The data including the puncture procedure, access characteristics, access-related complications and stone-free rates were assessed in four sequential groups. The puncture duration and number of times decreased from a mean of 4.4 min and 2.1 times for the first 60 patients to 1.3 min and 1.2 times for the last 60 patients. There was a significant decrease from 3.7 min and 1.8 times for the 61th-120th patients to 1.5 min and 1.3 times for the 121th-180th patients. All of the access-related severe bleeding appeared in the first 120 patients, while perforations only occurred in the first 60 patients. The stone-free rates were 68.3, 83.3, 90.0, and 93.3% for the four sequential groups. The increase in experience lead to an improvement in the puncture duration and times, which accompany with better stone-free rates and lower complications. We propose that 60 operations are sufficient to gain competency, and a cutoff point of 120 operations will allow the surgeon to achieve excellence in the solo US-guided PCNL.

  11. Measuring the depth of the caudal epidural space to prevent dural sac puncture during caudal block in children.

    PubMed

    Lee, Hyun Jeong; Min, Ji Young; Kim, Hyun Il; Byon, Hyo-Jin

    2017-05-01

    Caudal blocks are performed through the sacral hiatus in order to provide pain control in children undergoing lower abdominal surgery. During the block, it is important to avoid advancing the needle beyond the sacrococcygeal ligament too much to prevent unintended dural puncture. This study used demographic data to establish simple guidelines for predicting a safe needle depth in the caudal epidural space in children. A total of 141 children under 12 years old who had undergone lumbar-sacral magnetic resonance imaging were included. The T2 sagittal image that provided the best view of the sacrococcygeal membrane and the dural sac was chosen. We used Picture Achieving and Communication System (Centricity ® PACS, GE Healthcare Co.) to measure the distance between the sacrococcygeal ligament and the dural sac, the length of the sacrococcygeal ligament, and the maximum depth of the caudal space. There were strong correlations between age, weight, height, and BSA, and the distance between the sacrococcygeal ligament and dural sac, as well as the length of the sacrococcygeal ligament. Based on these findings, a simple formula to calculate the distance between the sacrococcygeal ligament and dural sac was developed: 25 × BSA (mm). This simple formula can accurately calculate the safe depth of the caudal epidural space to prevent unintended dural puncture during caudal block in children. However, further clinical studies based on this formula are needed to substantiate its utility. © 2017 John Wiley & Sons Ltd.

  12. Pain scores for intravenous cannulation and arterial blood gas test among emergency department patients.

    PubMed

    Ballesteros-Peña, Sendoa; Vallejo-De la Hoz, Gorka; Fernández-Aedo, Irrintzi

    2017-12-23

    To analyse vein catheterisation and blood gas test-related pain among adult patients in the emergency department and to explore pain score-related factors. An observational and multicentre research study was performed. Patients undergoing vein catheterisation or arterial puncture for gas test were included consecutively. After each procedure, patients scored the pain experienced using the NRS-11. 780 vein catheterisations and 101 blood gas tests were analysed. Venipuncture was scored with an average score of 2.8 (95% CI: 2.6-3), and arterial puncture with 3.6 (95%CI 3.1-4). Iatrogenic pain scores were associated with moderate - high difficulty procedures (P<.001); with the choice of the humeral rather than the radial artery (P=.02) in the gas test and correlated to baseline pain in venipunctures (P<.001). Pain scores related to other variables such as sex, place of origin or needle gauge did not present statistically significant differences. Vein catheterisation and blood gas test-related pain can be considered mild to moderately and moderately painful procedures, respectively. The pain score is associated with certain variables such as the difficulty of the procedure, the anatomic area of the puncture or baseline pain. A better understanding of painful effects related to emergency nursing procedures and the factors associated with pain self-perception could help to determine when and how to act to mitigate this undesired effect. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  13. An in vitro study of dural lesions produced by 25-gauge Quincke and Whitacre needles evaluated by scanning electron microscopy.

    PubMed

    Reina, M A; de Leon-Casasola, O A; Lopez, A; De Andres, J; Martin, S; Mora, M

    2000-01-01

    A study using scanning electron microscopy showed that although the laminas forming the dura mater are concentric and parallel to the surface of the medulla, the fiber layers' orientations are different in each sub-lamina, dispelling the conventional knowledge that all the fibers of the dura are arranged in a parallel direction. Thus, this study evaluated the dural lesions produced by Whitacre and Quincke spinal needles in the external and internal surface of the dura mater of the lower spine area in an attempt to gain more insight into the pathophysiology of postdural puncture headaches (PDPH). The T11-L4 dural membranes from 5 fresh (immediately after extraction of organs for transplantation), male patients declared brain dead, ages 23, 46, 48, 55, and 60 years, were excised by anterior laminectomy. Morphologic orientation of the membrane and normal pH were maintained with an apparatus designed for this purpose. One hundred punctures (20 on each sample) at 90-degree angles were done with a new needle each time, 50 with 25-gauge Whitacre and 50 with 25-gauge Quincke needles. Half of the punctures with the Quincke needles were done with the bevel in parallel direction to the axis of the spinal cord, and the rest with the bevel perpendicular to it. Fixation in solutions of 2.5% glutaraldehyde phosphate buffer, followed by dehydration with acetone, was done 15 minutes after the punctures. After acetone was removed at ideal conditions of temperature and pressure, the specimens were then metallized with carbon followed by gold and inspected under a scanning electron microscope. Twenty-five of the Whitacre and 23 of the Quincke punctures were found for evaluation. There were no differences in the cross-sectional area of the punctures produced by the Whitacre or Quincke needles on the dura. The area of the dural lesions produced by 25-gauge Quincke needles, 15 minutes after they have been withdrawn, was 0.023 mm2 (confidence interval [CI] 95%, 0.015 to 0.027) in the external aspect (epidural surface) and 0.034 mm2 (CI 95%, 0.018 to 0.051) in the internal aspect (arachnoid surface) of the dural sac. The area of the lesions produced by the 25-gauge Whitacre needles was 0.026 mm2 (CI 95%, 0.019 to 0.032) and 0.030 mm2 (CI 95%, 0.025 to 0.036) in the external and internal surfaces of the dural sac, respectively. There were no significant differences in the cross-sectional areas of the punctures produced by the 25-gauge Whitacre or 25-gauge Quincke needles. Moreover, with Quincke needles the dural lesions closed in an 88.3% (CI 95%, 86.3 to 92.4) and 82.7% (CI 95%, 74.1 to 90.9) of their original sizes in the epidural and arachnoid surfaces, respectively. With Whitacre needles, the closure occurred in an 86.8% (CI 95%, 83.8 to 90.3) and 84.8% (CI 95% 81.7 to 87.3) in the dural and arachnoid surfaces, respectively. However, there were differences in the morphology of the lesions. The Whitacre needles produced coarse lesions with significant destruction in the dura's fibers while the Quincke needles produced a 'U'-shaped lesion (flap) that mimics the opened lid of a tin can, regardless of the tip's direction. The needles produced lesions in the dura with different morphology and characteristics. Lesions with the Quincke needles resulted in a clean-cut opening in the dural membrane while the Whitacre needle produced a more traumatic opening with tearing and severe disruption of the collagen fibers. Thus, we hypothesized that the lower incidence of PDPH seen with the Whitacre needles may be explained, in part, by the inflammatory reaction produced by the tearing of the collagen fibers after dural penetration. This inflammatory reaction may result in a significant edema which may act as a plug limiting the leakage of cerebrospinal fluid.

  14. Correlation of geotextile puncture test methods : research brief.

    DOT National Transportation Integrated Search

    2017-05-01

    Geotextiles are commonly used in pavements, earth retaining structures, landfills and other geotechnical contexts. Various tests are conducted to evaluate and classify geotextiles to determine their suitability for each of these applications. The AST...

  15. 21 CFR 610.53 - Dating periods for licensed biological products.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... puncture device ......do ......do Do. Typhoid Vaccine 1 year ......do 18 months. ACD Whole Blood Not... hours from date of collection, provided labeling recommends storage between 1 and 6 °C. Yellow Fever...

  16. Lead levels - blood

    MedlinePlus

    Blood lead levels ... A blood sample is needed. Most of the time blood is drawn from a vein located on the inside ... may be used to puncture the skin. The blood collects in a small glass tube called a ...

  17. Patient Safety Center Organization

    DTIC Science & Technology

    2007-06-01

    placement Medicine, Surgery Lumbar puncture* Medicine Thoracentesis* Medicine Shoulder dystocia Obstetrics & Gynecology Mock code-depressed newborn...Airway 2) Team Training (using SimMan), 3) Endoscopy, 4) Shoulder Dystocia , 5) Episiotomy, and 6) Central Line Placement. The second group is

  18. Splenic trauma during abdominal wall liposuction: a case report

    PubMed Central

    Harnett, Paul; Koak, Yashwant; Baker, Daryl

    2008-01-01

    Summary A 35-year-old woman collapsed 18 hours after undergoing abdominal wall liposuction. Abdominal CT scan revealed a punctured spleen. She underwent an emergency splenectomy and made an uneventful recovery. PMID:18387911

  19. Cerebrospinal Fluid (CSF) Analysis

    MedlinePlus

    ... Internet]. Allina Health; c2017. Cerebrospinal fluid IgG measurement, quantitative [updated 2016 Mar 29; cited 2017 Oct 22]; [ ... Clinic [Internet]. Mayo Foundation for Medical Education and Research; c1998–2017. Lumbar puncture (spinal tap): Risks; 2014 ...

  20. 40 CFR 264.226 - Monitoring and inspection.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... absence of tears, punctures, or blisters; and (2) Soil-based and admixed liners and covers must be... dimensions, and level that avoids backup into the drainage layer and minimizes head in the sump. [47 FR 32357...

  1. 40 CFR 264.226 - Monitoring and inspection.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... absence of tears, punctures, or blisters; and (2) Soil-based and admixed liners and covers must be... dimensions, and level that avoids backup into the drainage layer and minimizes head in the sump. [47 FR 32357...

  2. 40 CFR 264.226 - Monitoring and inspection.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... absence of tears, punctures, or blisters; and (2) Soil-based and admixed liners and covers must be... dimensions, and level that avoids backup into the drainage layer and minimizes head in the sump. [47 FR 32357...

  3. 40 CFR 264.226 - Monitoring and inspection.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... absence of tears, punctures, or blisters; and (2) Soil-based and admixed liners and covers must be... dimensions, and level that avoids backup into the drainage layer and minimizes head in the sump. [47 FR 32357...

  4. 40 CFR 264.226 - Monitoring and inspection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... absence of tears, punctures, or blisters; and (2) Soil-based and admixed liners and covers must be... dimensions, and level that avoids backup into the drainage layer and minimizes head in the sump. [47 FR 32357...

  5. Stonefish sting

    MedlinePlus

    ... called antiserum to reverse the effect of the venom Medicine to treat symptoms X-rays Tetanus shot, if necessary ... hours. Outcome often depends on how much poisonous venom entered ... A puncture to the person's chest or abdomen may lead to death.

  6. Septic Arthritis

    MedlinePlus

    ... Weak immune system. People with a weak immune system are at greater risk of septic arthritis. This includes people with diabetes, kidney and liver problems, and those taking drugs that suppress their immune systems. Joint trauma. Animal bites, puncture woods or cuts ...

  7. Needles and Other Sharps (Safe Disposal Outside of Health Care Settings)

    MedlinePlus

    ... sharps containers are generally available through pharmacies, medical supply companies, health care providers and online. These containers are made of puncture-resistant plastic with leak-resistant sides and bottom. They also have a ...

  8. Collecting Samples for Testing

    MedlinePlus

    ... one or more hours to avoid a potential post-test spinal headache. The lumbar puncture procedure usually takes ... View sources NOTE: This article is based on research that ... of the Lab Tests Online Editorial Review Board . This article is periodically ...

  9. Animal bites - self-care

    MedlinePlus

    Bites - animals - self-care ... Most animal bites come from pets. Dog bites are common and most often happen to children. Cat bites are ... which can cause deeper puncture wounds. Most other animal bites are caused by stray or wild animals, ...

  10. Volume growth and puncture repair in conformal geometry

    NASA Astrophysics Data System (ADS)

    Eastwood, Michael G.; Gover, A. Rod

    2018-04-01

    Suppose M is a compact Riemannian manifold and p ∈ M an arbitrary point. We employ estimates on the volume growth around p to prove that the only conformal compactification of M ∖ { p } is M itself.

  11. 21 CFR 878.4011 - Tissue adhesive with adjunct wound closure device for topical approximation of skin.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY... approximated skin edges of wounds from surgical incisions, including punctures from minimally invasive surgery...

  12. 21 CFR 878.4011 - Tissue adhesive with adjunct wound closure device for topical approximation of skin.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY... approximated skin edges of wounds from surgical incisions, including punctures from minimally invasive surgery...

  13. 21 CFR 878.4011 - Tissue adhesive with adjunct wound closure device for topical approximation of skin.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY... approximated skin edges of wounds from surgical incisions, including punctures from minimally invasive surgery...

  14. Levalbuterol Oral Inhalation

    MedlinePlus

    ... it at room temperature and away from excess heat and moisture (not in the bathroom). Do not puncture the aerosol container and do not discard it in an incinerator or fire.Levalbuterol solution must be protected from light. Store unused vials ...

  15. [Improved method of studying the blood for sterility].

    PubMed

    Talapa, A I

    1983-05-01

    The technique used for the inoculation and subculturing of blood samples in testing them for sterility is described. This technique eliminates the possibility of contaminating the culture medium and the blood sample under test with extraneous bacterial flora. Blood samples were inoculated without opening the containers with the culture medium. Inoculation was made with the syringe and the needle used for taking the blood sample through the punctured rubber stopper closing the container. Subculturing on solid culture media was also carried out without opening the containers: the rubber stopper was punctured and the contents of the container withdrawn with a pipette needle. The use of this new technique made it possible to detect bacteremia in 12.8% of cases, only in persons with purulent and septic diseases, whereas by using the existing technique bacteremia was detected both in sick and healthy persons, in 38.6% and 26.6% of cases, respectively.

  16. Central charge from adiabatic transport of cusp singularities in the quantum Hall effect

    NASA Astrophysics Data System (ADS)

    Can, Tankut

    2017-04-01

    We study quantum Hall (QH) states on a punctured Riemann sphere. We compute the Berry curvature under adiabatic motion in the moduli space in the large N limit. The Berry curvature is shown to be finite in the large N limit and controlled by the conformal dimension of the cusp singularity, a local property of the mean density. Utilizing exact sum rules obtained from a Ward identity, we show that for the Laughlin wave function, the dimension of a cusp singularity is given by the central charge, a robust geometric response coefficient in the QHE. Thus, adiabatic transport of curvature singularities can be used to determine the central charge of QH states. We also consider the effects of threaded fluxes and spin-deformed wave functions. Finally, we give a closed expression for all moments of the mean density in the integer QH state on a punctured disk.

  17. Generalized type II hybrid ARQ scheme using punctured convolutional coding

    NASA Astrophysics Data System (ADS)

    Kallel, Samir; Haccoun, David

    1990-11-01

    A method is presented to construct rate-compatible convolutional (RCC) codes from known high-rate punctured convolutional codes, obtained from best-rate 1/2 codes. The construction method is rather simple and straightforward, and still yields good codes. Moreover, low-rate codes can be obtained without any limit on the lowest achievable code rate. Based on the RCC codes, a generalized type-II hybrid ARQ scheme, which combines the benefits of the modified type-II hybrid ARQ strategy of Hagenauer (1988) with the code-combining ARQ strategy of Chase (1985), is proposed and analyzed. With the proposed generalized type-II hybrid ARQ strategy, the throughput increases as the starting coding rate increases, and as the channel degrades, it tends to merge with the throughput of rate 1/2 type-II hybrid ARQ schemes with code combining, thus allowing the system to be flexible and adaptive to channel conditions, even under wide noise variations and severe degradations.

  18. Safety of Lumbar Puncture Procedures in Patients with Alzheimer's Disease

    PubMed Central

    Peskind, E.; Nordberg, A.; Darreh-Shori, T.; Soininen, H.

    2014-01-01

    Changes in cerebrospinal fluid (CSF) biomarkers are representative of biochemical changes in the brain. Collection of CSF by lumbar puncture (LP) is essential for biomarker analysis, which is important for research in neurodegenerative disorders. However, LP for research purposes has been controversial due to a reported high incidence of severe LP headache when using standard 18g or 20g Quincke needles with a beveled cutting tip. A procedural safety analysis was performed using the database of a multicenter, 13-week study of CSF cholinesterase activity. A 24g Sprotte atraumatic needle was used to collect CSF at baseline and at Week 13 from 63 older patients with mild to moderate Alzheimer's disease. There was a < 2% LP headache incidence, and a favorable safety profile was reported. In conclusion, LP performed with a 24g Sprotte atraumatic needle (blunt, “bullet” tip) was a well-tolerated procedure, with good acceptability. PMID:19519311

  19. [Comparison of port needle with safety device between Huber Plus (HP) and Poly PERF Safe (PPS)].

    PubMed

    Shimono, Chigusa; Tanaka, Atsuko; Fujita, Ai; Ishimoto, Miki; Oura, Shoji; Yamaue, Hiroki; Sato, Morio

    2010-05-01

    An embedded port is frequently used for outpatients with advanced cancer in central venous chemotherapy or hepatic arterial chemoinfusion. The port needle with a safety device in an ambulatory treatment center is indispensable for medical employees and patient plus family to reduce the risk of a needle puncture accident and to prevent iatrogenic infection. The port needle with safety system has been already introduced in our chemotherapy center. There are two types of port needle with safety device; Huber Plus (HP, Medicon Co., Ltd.) and POLY PERF Safe (PPS, Pyolax Device, Co., Ltd.). The comparison of the feasibility between HP and PPS was conducted by both medical employees and patients plus family using an inquiry score method. HP was highly regarded for its stability plus fixation and PPS for its usefulness in puncture and extraction of the needle. PPS was found to be preferable to HP based on the overall evaluation.

  20. [Our experience using "Huber Plus" needles in our infusion center].

    PubMed

    Tazumi, Keiko; Kouji, Keiko; Matsumura, Natsuko; Nabetani, Yoshiko; Kondo, Motoi; Tomono, Kazunori; Mizuki, Masao

    2008-01-01

    We conducted a pilot trial to compare the operability and safety of two huber needles in the infusion center. In the present study, we used huber needles without the safety cover and one huber needle with the safety cover (Huber Plus(R)). Both huber needles were used nine times. The successful puncture rate of the first time puncture and the incidence of needle accidents with both huber needles were 100% and 0%, respectively. The evaluation of pain and uneasiness by VAS (Visual Analogue scale)revealed the superiority of the safety needle over the than non-safety needle(pain: 3.8 vs 2.6, uneasiness: 3.7 vs 0.5). To our knowledge, this is the first report of the safety of the huber needle in Japan. This system may be recommended in Japan to avoid needle stick injuries, patient pain and uneasiness.

Top