  1. Accuracy of computer-calculated and manual QRS duration assessments: Clinical implications to select candidates for cardiac resynchronization therapy.

    PubMed

    De Pooter, Jan; El Haddad, Milad; Stroobandt, Roland; De Buyzere, Marc; Timmermans, Frank

    2017-06-01

    QRS duration (QRSD) plays a key role in the field of cardiac resynchronization therapy (CRT). Computer-calculated QRSD assessments are widely used, however inter-manufacturer differences have not been investigated in CRT candidates. QRSD was assessed in 377 digitally stored ECGs: 139 narrow QRS, 140 LBBB and 98 ventricular paced ECGs. Manual QRSD was measured as global QRSD, using digital calipers, by two independent observers. Computer-calculated QRSD was assessed by Marquette 12SL (GE Healthcare, Waukesha, WI, USA) and SEMA3 (Schiller, Baar, Switzerland). Inter-manufacturer differences of computer-calculated QRSD assessments vary among different QRS morphologies: narrow QRSD: 4 [2-9] ms (median [IQR]), p=0.010; LBBB QRSD: 7 [2-10] ms, p=0.003 and paced QRSD: 13 [6-18] ms, p=0.007. Interobserver differences of manual QRSD assessments measured: narrow QRSD: 4 [2-6] ms, p=non-significant; LBBB QRSD: 6 [3-12] ms, p=0.006; paced QRSD: 8 [4-18] ms, p=0.001. In LBBB ECGs, intraclass correlation coefficients (ICCs) were comparable for inter-manufacturer and interobserver agreement (ICC 0.830 versus 0.837). When assessing paced QRSD, manual measurements showed higher ICC compared to inter-manufacturer agreement (ICC 0.902 versus 0.776). Using guideline cutoffs of 130ms, up to 15% of the LBBB ECGs would be misclassified as <130ms or ≥130ms by at least one method. Using a cutoff of 150ms, this number increases to 33% of ECGs being misclassified. However, by combining LBBB-morphology and QRSD, the number of misclassified ECGs can be decreased by half. Inter-manufacturer differences in computer-calculated QRSD assessments are significant and may compromise adequate selection of individual CRT candidates when using QRSD as sole parameter. Paced QRSD should preferentially be assessed by manual QRSD measurements. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Ethnic differences in the association of QRS duration with ejection fraction and outcome in heart failure

    PubMed Central

    Gijsberts, Crystel M; Benson, Lina; Dahlström, Ulf; Sim, David; Yeo, Daniel P S; Ong, Hean Yee; Jaufeerally, Fazlur; Leong, Gerard K T; Ling, Lieng H; Richards, A Mark; de Kleijn, Dominique P V; Lund, Lars H; Lam, Carolyn S P

    2016-01-01

    Background QRS duration (QRSd) criteria for device therapy in heart failure (HF) were derived from predominantly white populations and ethnic differences are poorly understood. Methods We compared the association of QRSd with ejection fraction (EF) and outcomes between 839 Singaporean Asian and 11 221 Swedish white patients with HF having preserved EF (HFPEF)and HF having reduced EF (HFREF) were followed in prospective population-based HF studies. Results Compared with whites, Asian patients with HF were younger (62 vs 74 years, p<0.001), had smaller body size (height 163 vs 171 cm, weight 70 vs 80 kg, both p<0.001) and had more severely impaired EF (EF was <30% in 47% of Asians vs 28% of whites). Overall, unadjusted QRSd was shorter in Asians than whites (101 vs 104 ms, p<0.001). Lower EF was associated with longer QRSd (p<0.001), with a steeper association among Asians than whites (pinteraction<0.001), independent of age, sex and clinical covariates (including body size). Excluding patients with left bundle branch block (LBBB) and adjusting for clinical covariates, QRSd was similar in Asians and whites with HFPEF, but longer in Asians compared with whites with HFREF (p=0.001). Longer QRSd was associated with increased risk of HF hospitalisation or death (absolute 2-year event rate for ≤120 ms was 40% and for >120 ms it was 52%; HR for 10 ms increase of QRSd was 1.04 (1.03 to 1.06), p<0.001), with no interaction by ethnicity. Conclusion We found ethnic differences in the association between EF and QRSd among patients with HF. QRS prolongation was similarly associated with increased risk, but the implications for ethnicity-specific QRSd cut-offs in clinical decision-making require further study. PMID:27402805

  3. QRS duration predicts death and hospitalization among patients with atrial fibrillation irrespective of heart failure: evidence from the AFFIRM study

    PubMed Central

    Whitbeck, Matthew G.; Charnigo, Richard J.; Shah, Jignesh; Morales, Gustavo; Leung, Steve W.; Fornwalt, Brandon; Bailey, Alison L.; Ziada, Khaled; Sorrell, Vincent L.; Zegarra, Milagros M.; Thompson, Jenks; Hosn, Neil Aboul; Campbell, Charles L.; Gurley, John; Anaya, Paul; Booth, David C.; Biase, Luigi Di; Natale, Andrea; Smyth, Susan; Moliterno, David J.; Elayi, Claude S.

    2014-01-01

    Aims The association of QRS duration (QRSd) with morbidity and mortality is understudied in patients with atrial fibrillation (AF). We sought to assess any association of prolonged QRS with increased risk of death or hospitalization among patients with AF. Methods and results QRS duration was retrieved from the baseline electrocardiograms of patients enroled in the Atrial Fibrillation Follow-Up Investigation of Rhythm Management (AFFIRM) study and divided into three categories: <90, 90–119, ≥120 ms. Cox models were applied relating the hazards of mortality and hospitalizations to QRSd. Among 3804 patients with AF, 593 died and 2305 were hospitalized. Compared with those with QRS < 90 ms, patients with QRS ≥ 120 ms, had an increased mortality [hazard ratio (HR) 1.61, 95% confidence interval (CI): 1.29–2.03, P < 0.001] and hospitalizations (HR 1.14, 95% CI: 1.07–1.34, P = 0.043) over an average follow-up of 3.5 years. Importantly, for patients with QRS 90–119 ms, mortality and hospitalization were also increased (HR 1.31, P = 0.005 and 1.11, P = 0.026, respectively). In subgroup analysis based on heart failure (HF) status (previously documented or ejection fraction <40%), mortality was increased for QRS ≥ 120 ms patients with (HR 1.87, P < 0.001) and without HF (HR 1.63, P = 0.02). In the QRS 90–119 ms group, mortality was increased (HR 1.38, P = 0.03) for those with HF, but not significantly among those without HF (HR 1.23, P = 0.14). Conclusion Among patients with AF, QRSd ≥ 120 ms was associated with a substantially increased risk for mortality (all-cause, cardiovascular, and arrhythmic) and hospitalization. Interestingly, an increased mortality was also observed among those with QRS 90–119 ms and concomitant HF. PMID:24368753

  4. Accuracy of manual QRS duration assessment: its importance in patient selection for cardiac resynchronization and implantable cardioverter defibrillator therapy.

    PubMed

    Tomlinson, David R; Bashir, Yaver; Betts, Timothy R; Rajappan, Kim

    2009-05-01

    Patients with left ventricular systolic dysfunction and electrocardiographic QRS duration (QRSd) >or=120 ms may obtain symptomatic and prognostic benefits from cardiac resynchronization therapy (CRT). However, clinical trials do not describe the methods used to measure QRSd. We investigated the effect of electrocardiogram (ECG) display format and paper speed on the accuracy of manual QRSd assessment and concordance of manual QRSd with computer-calculated mean and maximal QRSd. Six cardiologists undertook QRSd measurements on ECGs, with computer-calculated mean QRSd close to 120 ms. Display formats were 12-lead, 6-limb, and 6-precordial leads, each at 25 and 50 mm/s. When the computer-calculated mean was used to define QRSd, manual assessment demonstrated 97 and 83% concordance at categorizing QRSd as < and >or=120 ms, respectively. Using the computer-calculated maximal QRSd, manual assessment demonstrated 83% concordance when QRSd was <120 ms and 19% concordance when QRSd was >or=120 ms. The six-precordial lead format demonstrated significantly less intra and inter-observer variabilities than the 12-lead, but this did not improve concordance rates. Manual QRSd assessments demonstrate significant variability, and concordance with computer-calculated measurement depends on whether QRSd is defined as the mean or maximal value. Consensus is required both on the most appropriate definition of QRSd and its measurement.

  5. Ethnic differences in the association of QRS duration with ejection fraction and outcome in heart failure.

    PubMed

    Gijsberts, Crystel M; Benson, Lina; Dahlström, Ulf; Sim, David; Yeo, Daniel P S; Ong, Hean Yee; Jaufeerally, Fazlur; Leong, Gerard K T; Ling, Lieng H; Richards, A Mark; de Kleijn, Dominique P V; Lund, Lars H; Lam, Carolyn S P

    2016-09-15

    QRS duration (QRSd) criteria for device therapy in heart failure (HF) were derived from predominantly white populations and ethnic differences are poorly understood. We compared the association of QRSd with ejection fraction (EF) and outcomes between 839 Singaporean Asian and 11 221 Swedish white patients with HF having preserved EF (HFPEF)and HF having reduced EF (HFREF) were followed in prospective population-based HF studies. Compared with whites, Asian patients with HF were younger (62 vs 74 years, p<0.001), had smaller body size (height 163 vs 171 cm, weight 70 vs 80 kg, both p<0.001) and had more severely impaired EF (EF was <30% in 47% of Asians vs 28% of whites). Overall, unadjusted QRSd was shorter in Asians than whites (101 vs 104 ms, p<0.001). Lower EF was associated with longer QRSd (p<0.001), with a steeper association among Asians than whites (pinteraction<0.001), independent of age, sex and clinical covariates (including body size). Excluding patients with left bundle branch block (LBBB) and adjusting for clinical covariates, QRSd was similar in Asians and whites with HFPEF, but longer in Asians compared with whites with HFREF (p=0.001). Longer QRSd was associated with increased risk of HF hospitalisation or death (absolute 2-year event rate for ≤120 ms was 40% and for >120 ms it was 52%; HR for 10 ms increase of QRSd was 1.04 (1.03 to 1.06), p<0.001), with no interaction by ethnicity. We found ethnic differences in the association between EF and QRSd among patients with HF. QRS prolongation was similarly associated with increased risk, but the implications for ethnicity-specific QRSd cut-offs in clinical decision-making require further study. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  6. Association between QRS duration and obstructive sleep apnea.

    PubMed

    Gupta, Shuchita; Cepeda-Valery, Beatriz; Romero-Corral, Abel; Shamsuzzaman, Abu; Somers, Virend K; Pressman, Gregg S

    2012-12-15

    Both obstructive sleep apnea (OSA) and prolonged QRS duration are associated with hypertension, heart failure, and sudden cardiac death. However, possible links between QRS duration and OSA have not been explored. Cross-sectional study of 221 patients who underwent polysomnography at our center. Demographics, cardiovascular risk factors and ECG were collected to explore a relationship between OSA and QRS duration. The apnea-hypopnea index (AHI) was positively correlated with QRS duration (r = 0.141, p = 0.03). Patients were divided into 3 groups: AHI < 5 (61), AHI 5-29 (104), and AHI > 30 (55). The mean QRS duration prolonged significantly as OSA worsened (AHI < 5, 85 ± 9.5; AHI 5-29, 89 ± 11.9; and AHI > 30, 95 ± 19.9 ms, p = 0.001). QRS ≥ 100 ms was present in 12.7% of patients with severe OSA compared with 0% in the rest of the sample (p < 0.0001). After adjustment for age, race, and cardiovascular risk factors, this association remained significant in women but not in men. QRS duration and OSA were significantly associated. Severity of OSA independently predicted prolonged QRS in women but not men. Nevertheless, prolongation of QRS duration in either sex may potentiate arrhythmic risks associated with OSA.

  7. Association between QRS Duration and Obstructive Sleep Apnea

    PubMed Central

    Gupta, Shuchita; Cepeda-Valery, Beatriz; Romero-Corral, Abel; Shamsuzzaman, Abu; Somers, Virend K.; Pressman, Gregg S.

    2012-01-01

    Background: Both obstructive sleep apnea (OSA) and prolonged QRS duration are associated with hypertension, heart failure, and sudden cardiac death. However, possible links between QRS duration and OSA have not been explored. Methods: Cross-sectional study of 221 patients who underwent polysomnography at our center. Demographics, cardiovascular risk factors and ECG were collected to explore a relationship between OSA and QRS duration. Results: The apnea-hypopnea index (AHI) was positively correlated with QRS duration (r = 0.141, p = 0.03). Patients were divided into 3 groups: AHI < 5 (61), AHI 5-29 (104), and AHI > 30 (55). The mean QRS duration prolonged significantly as OSA worsened (AHI < 5, 85 ± 9.5; AHI 5-29, 89 ± 11.9; and AHI > 30, 95 ± 19.9 ms, p = 0.001). QRS ≥ 100 ms was present in 12.7% of patients with severe OSA compared with 0% in the rest of the sample (p < 0.0001). After adjustment for age, race, and cardiovascular risk factors, this association remained significant in women but not in men. Conclusion: QRS duration and OSA were significantly associated. Severity of OSA independently predicted prolonged QRS in women but not men. Nevertheless, prolongation of QRS duration in either sex may potentiate arrhythmic risks associated with OSA. Citation: Gupta S; Cepeda-Valery B; Romero-Corral A; Shamsuzzaman A; Somers VK; Pressman GS. Association between QRS duration and obstructive sleep apnea. J Clin Sleep Med 2012;8(6):649-654. PMID:23243398

  8. Relation of QRS duration to mortality in a community-based cohort with hypertrophic cardiomyopathy.

    PubMed

    Bongioanni, Sergio; Bianchi, Francesca; Migliardi, Alessandro; Gnavi, Roberto; Pron, Paolo Giay; Casetta, Marzia; Conte, Maria Rosa

    2007-08-01

    A prolonged QRS duration on the standard electrocardiogram is associated with an increased risk of cardiovascular death in cardiomyopathies of different origin. However, the relation between QRS duration and prognosis in hypertrophic cardiomyopathy (HC) remains undefined. We assessed the relation between QRS duration and cardiovascular death in 241 consecutive patients with HC. The study cohort was divided into 2 groups according to QRS duration: <120 and > or =120 ms. Of the 241 patients, 191 (79%) had a QRS duration <120 ms and 50 (21%) a QRS duration > or =120 ms. During a mean follow-up of 7.9 +/- 5.1 years, 35 patients died of cardiovascular causes related to HC. Of these 35 patients, 13 (6%) had a QRS duration <120 ms and 22 (43%) had a QRS duration > or =120 ms (p <0.01). Risk of cardiovascular death was significantly higher in patients with a QRS duration > or =120 ms than in those with a QRS duration <120 ms (relative risk 5.2, p <0.0001). At 8-year follow-up, cumulative risks of HC-related death were 7.1% in patients with a QRS duration <120 ms and 55% in those with a QRS duration > or =120 ms. Multivariate analysis confirmed that a QRS duration > or =120 ms was independently associated with an increased risk of cardiovascular death (hazard ratio 3.2, p = 0.007). New York Heart Association functional class III/IV was the only other clinical variable significantly and independently associated with an increased risk of cardiovascular death. In conclusion, in patients with HC, QRS duration on standard electrocardiogram is directly related to cardiovascular mortality, and a QRS duration > or =120 ms is a strong and independent predictor of prognosis.

  9. Prolonged QRS duration on surface electrocardiogram is associated with left ventricular restrictive filling pattern.

    PubMed

    Erdoğan, Turan; Durakoğlugil, Murtaza Emre; Çiçek, Yüksel; Çetin, Mustafa; Duman, Hakan; Şatiroğlu, Ömer; Çelik, Şükrü

    2017-03-01

    Prolonged QRS duration is associated with decreased left ventricular (LV) systolic function. However, the relation between LV restrictive filling pattern (RFP) and QRS duration has not been investigated yet. The purpose of our study was to assess this relationship. We analyzed standard 12-lead surface electrocardiogram (ECG) of 155 consecutive patients. Mitral inflow and septal tissue velocities were obtained using the apical 4-chamber view with pulsed Doppler echocardiography. Patients were divided into 2 groups according to measured deceleration time (DT): restrictive (with DT ≤130 ms) or non-restrictive (with DT >130 ms). QRS duration was significantly longer in the restrictive group than in the non-restrictive group (0.101 vs. 0.090 s, p  < 0.0001). QRS duration of >0.10 s was highly specific (82.6%), but modestly sensitive (64.7%), for the prediction of LV RFP. Multivariate analyses demonstrated that E/A ratio, peak E, peak A, septal e', and a' velocities were significantly associated with RFP. Prolonged QRS duration (>0.10 s) obtained from a standard resting 12-lead ECG is associated with LV RFP. However, the relationship of QRS duration with RFP was not independent of echocardiographic parameters.

  10. Prolonged QRS duration on surface electrocardiogram is associated with left ventricular restrictive filling pattern

    PubMed Central

    Erdoğan, Turan; Durakoğlugil, Murtaza Emre; Çiçek, Yüksel; Çetin, Mustafa; Duman, Hakan; Şatiroğlu, Ömer; Çelik, Şükrü

    2017-01-01

    Background Prolonged QRS duration is associated with decreased left ventricular (LV) systolic function. However, the relation between LV restrictive filling pattern (RFP) and QRS duration has not been investigated yet. The purpose of our study was to assess this relationship. Methods We analyzed standard 12-lead surface electrocardiogram (ECG) of 155 consecutive patients. Mitral inflow and septal tissue velocities were obtained using the apical 4-chamber view with pulsed Doppler echocardiography. Patients were divided into 2 groups according to measured deceleration time (DT): restrictive (with DT ≤130 ms) or non-restrictive (with DT >130 ms). Results QRS duration was significantly longer in the restrictive group than in the non-restrictive group (0.101 vs. 0.090 s, p < 0.0001). QRS duration of >0.10 s was highly specific (82.6%), but modestly sensitive (64.7%), for the prediction of LV RFP. Multivariate analyses demonstrated that E/A ratio, peak E, peak A, septal e’, and a’ velocities were significantly associated with RFP. Conclusions Prolonged QRS duration (>0.10 s) obtained from a standard resting 12-lead ECG is associated with LV RFP. However, the relationship of QRS duration with RFP was not independent of echocardiographic parameters. PMID:28932490

  11. The Shortest QRS Duration of an Electrocardiogram Might Be an Optimal Electrocardiographic Predictor for Response to Cardiac Resynchronization Therapy.

    PubMed

    Chen, Jan-Yow; Lin, Kuo-Hung; Chang, Kuan-Cheng; Chou, Che-Yi

    2017-08-03

    QRS duration has been associated with the response to cardiac resynchronization therapy (CRT). However, the methods for defining QRS duration to predict the outcome of CRT have discrepancies in previous reports. The aim of this study was to determine an optimal measurement of QRS duration to predict the response to CRT.Sixty-one patients who received CRT were analyzed. All patients had class III-IV heart failure, left ventricular ejection fraction not more than 35%, and complete left bundle branch block. The shortest, longest, and average QRS durations from the 12 leads of each electrocardiogram (ECG) were measured. The responses to CRT were determined using the changes in echocardiography after 6 months. Thirty-five (57.4%) patients were responders and 26 (42.6%) patients were non-responders. The pre-procedure shortest, average, and longest QRS durations and the QRS shortening (ΔQRS) of the shortest QRS duration were significantly associated with the response to CRT in a univariate logistic regression analysis (P = 0.002, P = 0.03, P = 0.04 and P = 0.04, respectively). Based on the measurement of the area under curve of the receiver operating characteristic curve, only the pre-procedure shortest QRS duration and the ΔQRS of the shortest QRS duration showed significant discrimination for the response to CRT (P = 0.002 and P = 0.038, respectively). Multivariable logistic regression showed the pre-procedure shortest QRS duration is an independent predictor for the response to CRT.The shortest QRS duration from the 12 leads of the electrocardiogram might be an optimal measurement to predict the response to CRT.

  12. Association of QRS duration and survival in dogs with dilated cardiomyopathy: a retrospective study of 266 clinical cases.

    PubMed

    Pedro, Brigite M; Alves, Joana V; Cripps, Peter J; Stafford Johnson, Mike J; Martin, Mike W S

    2011-12-01

    The purpose of this study was to investigate the prognostic value of QRS duration in dogs with dilated cardiomyopathy (DCM) by studying its relationship with survival time. The medical records of dogs diagnosed with DCM were retrospectively searched for good quality ECG tracings. The QRS duration was measured from the ECG tracing and two different models were used: binary variable (dogs were divided into 2 groups based on a QRS duration of <60 ms or ≥60 ms) and continuous variable. The survival times were analysed by the Kaplan-Meier method and Cox's proportional hazard model. 266 dogs met the inclusion and exclusion criteria. A QRS duration ≥60 ms was associated with a reduced survival time compared to those with a QRS duration <60 ms (Hazard Ratio of 1.34, 95% CI 1.05-1.71, P = 0.02). When considered as a continuous variable the Hazard Ratio was 1.015 for each increase in QRS duration of 1 ms (95% CI 1.006-1.024, p = 0.001).Dogs with a QRS duration < 60 ms had a median survival time (IQ range) of 25 weeks (97-65) and dogs with a QRS duration ≥60 ms had a median survival time (IQ range) of 13 weeks (3-34). The measurement of QRS duration is relatively simple to perform from a surface ECG recording. A duration ≥60 ms is associated with shorter survival times in dogs with DCM, which may provide practitioners with additional prognostic information. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Programming Cardiac Resynchronization Therapy for Electrical Synchrony: Reaching Beyond Left Bundle Branch Block and Left Ventricular Activation Delay.

    PubMed

    Varma, Niraj; O'Donnell, David; Bassiouny, Mohammed; Ritter, Philippe; Pappone, Carlo; Mangual, Jan; Cantillon, Daniel; Badie, Nima; Thibault, Bernard; Wisnoskey, Brian

    2018-02-06

    QRS narrowing following cardiac resynchronization therapy with biventricular (BiV) or left ventricular (LV) pacing is likely affected by patient-specific conduction characteristics (PR, qLV, LV-paced propagation interval), making a universal programming strategy likely ineffective. We tested these factors using a novel, device-based algorithm (SyncAV) that automatically adjusts paced atrioventricular delay (default or programmable offset) according to intrinsic atrioventricular conduction. Seventy-five patients undergoing cardiac resynchronization therapy (age 66±11 years; 65% male; 32% with ischemic cardiomyopathy; LV ejection fraction 28±8%; QRS duration 162±16 ms) with intact atrioventricular conduction (PR interval 194±34, range 128-300 ms), left bundle branch block, and optimized LV lead position were studied at implant. QRS duration (QRSd) reduction was compared for the following pacing configurations: nominal simultaneous BiV (Mode I: paced/sensed atrioventricular delay=140/110 ms), BiV+SyncAV with 50 ms offset (Mode II), BiV+SyncAV with offset that minimized QRSd (Mode III), or LV-only pacing+SyncAV with 50 ms offset (Mode IV). The intrinsic QRSd (162±16 ms) was reduced to 142±17 ms (-11.8%) by Mode I, 136±14 ms (-15.6%) by Mode IV, and 132±13 ms (-17.8%) by Mode II. Mode III yielded the shortest overall QRSd (123±12 ms, -23.9% [ P <0.001 versus all modes]) and was the only configuration without QRSd prolongation in any patient. QRS narrowing occurred regardless of QRSd, PR, or LV-paced intervals, or underlying ischemic disease. Post-implant electrical optimization in already well-selected patients with left bundle branch block and optimized LV lead position is facilitated by patient-tailored BiV pacing adjusted to intrinsic atrioventricular timing using an automatic device-based algorithm. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  14. Data on association between QRS duration on prehospital ECG and mortality in patients with confirmed STEMI.

    PubMed

    Hansen, Rikke; Frydland, Martin; Møller-Helgestad, Ole Kristian; Lindholm, Matias Greve; Jensen, Lisette Okkels; Holmvang, Lene; Ravn, Hanne Berg; Kjærgaard, Jesper; Hassager, Christian; Møller, Jacob Eifer

    2017-12-01

    Data presented in this article relates to the research article entitled " Association between QRS duration on prehospital ECG and mortality in patients with suspected STEMI" (Hansen et al., in press) [1]. Data on the prognostic effect of automatically recoded QRS duration on prehospital ECG and presence of classic left and right bundle branch block in 1777 consecutive patients with confirmed ST segment elevation AMI is presented. Multivariable analysis, suggested that QRS duration >111 ms, left bundle branch block and right bundle branch block were independent predictors of 30 days all-cause mortality. For interpretation and discussion of these data, refer to the research article referenced above.

  15. Comparison of QRS Duration and Associated Cardiovascular Events in American Indian Men Versus Women (The Strong Heart Study).

    PubMed

    Deen, Jason F; Rhoades, Dorothy A; Noonan, Carolyn; Best, Lyle G; Okin, Peter M; Devereux, Richard B; Umans, Jason G

    2017-06-01

    Electrocardiographic QRS duration at rest is associated with sudden cardiac death and death from coronary heart disease in the general population. However, its relation to cardiovascular events in American Indians, a population with persistently high cardiovascular disease mortality, is unknown. The relation of QRS duration to incident cardiovascular disease during 17.2 years of follow-up was assessed in 1,851 male and female Strong Heart Study participants aged 45 to 74 years without known cardiovascular disease at baseline. Cox regression with robust standard error estimates was used to determine the association between quintiles of QRS duration and incident cardiovascular disease in gender-stratified analyses, adjusted for age, systolic blood pressure, hypertension, antihypertensive medication use, body mass index, current smoking, diabetes, total cholesterol, high-density lipoprotein cholesterol, and albuminuria. In women only, QRS duration in the highest quintile (≥105 ms) conferred significantly higher risk of cardiovascular disease than QRS duration in the lowest quintile (64 to 84 ms) (hazard ratio 1.6, 95% CI 1.1 to 2.4) likely because of higher risks of coronary heart disease (hazard ratio 1.8, 95% CI 1.1 to 3.1) and myocardial infarction (hazard ratio 2.1, 95% CI 1.0 to 4.7). Furthermore, when added to the Strong Heart Study Coronary Heart Disease Risk Calculator, QRS duration significantly improved prediction of future coronary heart disease events in women (Net Reclassification Index 0.17, 95% CI 0.06 to 0.47). In conclusion, QRS duration is an independent predictor of cardiovascular disease in women in the Strong Heart Study cohort and may have value in estimating risk in populations with similar risk profiles and a high lifetime incidence of cardiovascular disease. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Fine-mapping, novel loci identification, and SNP association transferability in a genome-wide association study of QRS duration in African Americans

    PubMed Central

    Evans, Daniel S.; Avery, Christy L.; Nalls, Mike A.; Li, Guo; Barnard, John; Smith, Erin N.; Tanaka, Toshiko; Butler, Anne M.; Buxbaum, Sarah G.; Alonso, Alvaro; Arking, Dan E.; Berenson, Gerald S.; Bis, Joshua C.; Buyske, Steven; Carty, Cara L.; Chen, Wei; Chung, Mina K.; Cummings, Steven R.; Deo, Rajat; Eaton, Charles B.; Fox, Ervin R.; Heckbert, Susan R.; Heiss, Gerardo; Hindorff, Lucia A.; Hsueh, Wen-Chi; Isaacs, Aaron; Jamshidi, Yalda; Kerr, Kathleen F.; Liu, Felix; Liu, Yongmei; Lohman, Kurt K.; Magnani, Jared W.; Maher, Joseph F.; Mehra, Reena; Meng, Yan A.; Musani, Solomon K.; Newton-Cheh, Christopher; North, Kari E.; Psaty, Bruce M.; Redline, Susan; Rotter, Jerome I.; Schnabel, Renate B.; Schork, Nicholas J.; Shohet, Ralph V.; Singleton, Andrew B.; Smith, Jonathan D.; Soliman, Elsayed Z.; Srinivasan, Sathanur R.; Taylor, Herman A.; Van Wagoner, David R.; Wilson, James G.; Young, Taylor; Zhang, Zhu-Ming; Zonderman, Alan B.; Evans, Michele K.; Ferrucci, Luigi; Murray, Sarah S.; Tranah, Gregory J.; Whitsel, Eric A.; Reiner, Alex P.; Sotoodehnia, Nona

    2016-01-01

    The electrocardiographic QRS duration, a measure of ventricular depolarization and conduction, is associated with cardiovascular mortality. While single nucleotide polymorphisms (SNPs) associated with QRS duration have been identified at 22 loci in populations of European descent, the genetic architecture of QRS duration in non-European populations is largely unknown. We therefore performed a genome-wide association study (GWAS) meta-analysis of QRS duration in 13,031 African Americans from ten cohorts and a transethnic GWAS meta-analysis with additional results from populations of European descent. In the African American GWAS, a single genome-wide significant SNP association was identified (rs3922844, P = 4 × 10−14) in intron 16 of SCN5A, a voltage-gated cardiac sodium channel gene. The QRS-prolonging rs3922844 C allele was also associated with decreased SCN5A RNA expression in human atrial tissue (P = 1.1 × 10−4). High density genotyping revealed that the SCN5A association region in African Americans was confined to intron 16. Transethnic GWAS meta-analysis identified novel SNP associations on chromosome 18 in MYL12A (rs1662342, P = 4.9 × 10−8) and chromosome 1 near CD1E and SPTA1 (rs7547997, P = 7.9 × 10−9). The 22 QRS loci previously identified in populations of European descent were enriched for significant SNP associations with QRS duration in African Americans (P = 9.9 × 10−7), and index SNP associations in or near SCN5A, SCN10A, CDKN1A, NFIA, HAND1, TBX5 and SETBP1 replicated in African Americans. In summary, rs3922844 was associated with QRS duration and SCN5A expression, two novel QRS loci were identified using transethnic meta-analysis, and a significant proportion of QRS–SNP associations discovered in populations of European descent were transferable to African Americans when adequate power was achieved. PMID:27577874

  17. Fine-mapping, novel loci identification, and SNP association transferability in a genome-wide association study of QRS duration in African Americans.

    PubMed

    Evans, Daniel S; Avery, Christy L; Nalls, Mike A; Li, Guo; Barnard, John; Smith, Erin N; Tanaka, Toshiko; Butler, Anne M; Buxbaum, Sarah G; Alonso, Alvaro; Arking, Dan E; Berenson, Gerald S; Bis, Joshua C; Buyske, Steven; Carty, Cara L; Chen, Wei; Chung, Mina K; Cummings, Steven R; Deo, Rajat; Eaton, Charles B; Fox, Ervin R; Heckbert, Susan R; Heiss, Gerardo; Hindorff, Lucia A; Hsueh, Wen-Chi; Isaacs, Aaron; Jamshidi, Yalda; Kerr, Kathleen F; Liu, Felix; Liu, Yongmei; Lohman, Kurt K; Magnani, Jared W; Maher, Joseph F; Mehra, Reena; Meng, Yan A; Musani, Solomon K; Newton-Cheh, Christopher; North, Kari E; Psaty, Bruce M; Redline, Susan; Rotter, Jerome I; Schnabel, Renate B; Schork, Nicholas J; Shohet, Ralph V; Singleton, Andrew B; Smith, Jonathan D; Soliman, Elsayed Z; Srinivasan, Sathanur R; Taylor, Herman A; Van Wagoner, David R; Wilson, James G; Young, Taylor; Zhang, Zhu-Ming; Zonderman, Alan B; Evans, Michele K; Ferrucci, Luigi; Murray, Sarah S; Tranah, Gregory J; Whitsel, Eric A; Reiner, Alex P; Sotoodehnia, Nona

    2016-10-01

    The electrocardiographic QRS duration, a measure of ventricular depolarization and conduction, is associated with cardiovascular mortality. While single nucleotide polymorphisms (SNPs) associated with QRS duration have been identified at 22 loci in populations of European descent, the genetic architecture of QRS duration in non-European populations is largely unknown. We therefore performed a genome-wide association study (GWAS) meta-analysis of QRS duration in 13,031 African Americans from ten cohorts and a transethnic GWAS meta-analysis with additional results from populations of European descent. In the African American GWAS, a single genome-wide significant SNP association was identified (rs3922844, P = 4 × 10 -14 ) in intron 16 of SCN5A, a voltage-gated cardiac sodium channel gene. The QRS-prolonging rs3922844 C allele was also associated with decreased SCN5A RNA expression in human atrial tissue (P = 1.1 × 10 -4 ). High density genotyping revealed that the SCN5A association region in African Americans was confined to intron 16. Transethnic GWAS meta-analysis identified novel SNP associations on chromosome 18 in MYL12A (rs1662342, P = 4.9 × 10 -8 ) and chromosome 1 near CD1E and SPTA1 (rs7547997, P = 7.9 × 10 -9 ). The 22 QRS loci previously identified in populations of European descent were enriched for significant SNP associations with QRS duration in African Americans (P = 9.9 × 10 -7 ), and index SNP associations in or near SCN5A, SCN10A, CDKN1A, NFIA, HAND1, TBX5 and SETBP1 replicated in African Americans. In summary, rs3922844 was associated with QRS duration and SCN5A expression, two novel QRS loci were identified using transethnic meta-analysis, and a significant proportion of QRS-SNP associations discovered in populations of European descent were transferable to African Americans when adequate power was achieved. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions

  18. Systolic blood pressure but not electrocardiogram QRS duration is associated with heart rate variability (HRV): a cross-sectional study in rural Australian non-diabetics.

    PubMed

    Lee, Yvonne Yin Leng; Jelinek, Herbert F; McLachlan, Craig S

    2017-01-01

    A positive correlation between ECG derived QRS duration and heart rate variability (HRV) parameters had previously been reported in young healthy adults. We note this study used a narrow QRS duration range, and did not adjust for systolic blood pressure. Our aims are to investigate associations between systolic blood pressure (SBP), QRS duration and HRV in a rural aging population. A retrospective cross sectional population was obtained from the CSU Diabetes Screening Research Initiative data base where 200 participants had no diabetes or pre-diabetes. SBP data were matched with ECG derived QRS duration and HRV parameters. HRV parameters were calculated from R-R intervals. Resting 12-lead electrocardiograms were obtained from each subject using a Welch Allyn PC-Based ECG system. Pearson correlation analysis revealed no statistically significant associations between HRV parameters and QRS duration. No significant mean differences in HRV parameter subgroups across defined QRS cut-offs were found. SBP > 146 mmHg was associated with increasing QRS durations, however this association disappeared once models were adjusted for age and gender. SBP was also significantly associated with a number of HRV parameters using Pearson correlation analysis, including high frequency (HF) ( p  < 0.05), HFln ( p  < 0.02), RMSDD ( p  < 0.02) and non-linear parameters; ApEN ( p  < 0.001) were negatively correlated with increasing SBP while the low frequency to high frequency ratio (LF/HF) increased with increasing SBP ( p  < 0.03). Our results do not support associations between ECG derived R-R derived HRV parameters and QRS duration in aging populations. We suggest that ventricular conduction as determined by QRS duration is independent of variations in SA-node heart rate variability.

  19. Improved symptoms, physical limitation, and self-efficacy after resynchronization in a patient with heart failure and a prolonged QRS duration.

    PubMed

    Conaway, Darcy G; Sullivan, Robbie; McCullough, Peter A

    2004-01-01

    This report examines the impact of resynchronization therapy in a patient with class IV heart failure and a prolonged QRS duration on electrocardiogram. The Kansas City Cardiomyopathy Questionnaire (KCCQ) was used to assess the patient's health status prior to, immediately after, and 2 months after placement of a biventricular pacemaker. B-type natriuretic peptide (BNP) values and electrocardiogram QRS duration were recorded to further document clinical status. Our patient experienced statistically significant improvements in 7 of 10 KCCQ domains after resynchronization. QRS duration narrowed following the procedure and BNP values decreased. Resynchronization therapy improved this patient's symptoms, physical limitations, and self-efficacy when maximal medical therapy failed.

  20. Are the QRS duration and ST depression cut-points from the Seattle criteria too conservative?

    PubMed

    Dunn, Tim; Abdelfattah, Ramy; Aggarwal, Sonya; Pickham, David; Hadley, David; Froelicher, Victor

    2015-01-01

    Screening athletes with ECGs is aimed at identifying "at-risk" individuals who may have a cardiac condition predisposing them to sudden cardiac death. The Seattle criteria highlight QRS duration greater than 140 ms and ST segment depression in two or more leads greater than 50 μV as two abnormal ECG patterns associated with sudden cardiac death. High school, college, and professional athletes underwent 12 lead ECGs as part of routine pre-participation physicals. Prevalence of prolonged QRS duration was measured using cut-points of 120, 125, 130, and 140 ms. ST segment depression was measured in all leads except leads III, aVR, and V1 with cut-points of 25 μV and 50 μV. Between June 2010 and November 2013, 1595 participants including 297 (167 male, mean age 16.2) high school athletes, 1016 (541 male, mean age 18.8) college athletes, and 282 (mean age 26.6) male professional athletes underwent screening with an ECG. Only 3 athletes (0.2%) had a QRS duration greater than 125 ms. ST segment depression in two or more leads greater than 50 μV was uncommon (0.8%), while the prevalence of ST segment depression in two or more leads increased to 4.5% with a cut-point of 25 μV. Changing the QRS duration cut-point to 125 ms would increase the sensitivity of the screening ECG, without a significant increase in false-positives. However, changing the ST segment depression cut-point to 25 μV would lead to a significant increase in false-positives and would therefore not be justified. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Right precordial-directed electrocardiographical markers identify arrhythmogenic right ventricular cardiomyopathy in the absence of conventional depolarization or repolarization abnormalities.

    PubMed

    Cortez, Daniel; Svensson, Anneli; Carlson, Jonas; Graw, Sharon; Sharma, Nandita; Brun, Francesca; Spezzacatene, Anita; Mestroni, Luisa; Platonov, Pyotr G

    2017-10-13

    Arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) carries a risk of sudden death. We aimed to assess whether vectorcardiographic (VCG) parameters directed toward the right heart and a measured angle of the S-wave would help differentiate ARVD/C with otherwise normal electrocardiograms from controls. Task Force 2010 definite ARVD/C criteria were met for all patients. Those who did not fulfill Task Force depolarization or repolarization criteria (-ECG) were compared with age and gender-matched control subjects. Electrocardiogram measures of a 3-dimentional spatial QRS-T angle, a right-precordial-directed orthogonal QRS-T (RPD) angle, a root mean square of the right sided depolarizing forces (RtRMS-QRS), QRS duration (QRSd) and the corrected QT interval (QTc), and a measured angle including the upslope and downslope of the S-wave (S-wave angle) were assessed. Definite ARVD/C was present in 155 patients by 2010 Task Force criteria (41.7 ± 17.6 years, 65.2% male). -ECG ARVD/C patients (66 patients) were compared to 66 control patients (41.7 ± 17.6 years, 65.2% male). All parameters tested except the QRSd and QTc significantly differentiated -ECG ARVD/C from control patients (p < 0.004 to p < 0.001). The RPD angle and RtRMS-QRS best differentiated the groups. Combined, the 2 novel criteria gave 81.8% sensitivity, 90.9% specificity and odds ratio of 45.0 (95% confidence interval 15.8 to 128.2). ARVD/C disease process may lead to development of subtle ECG abnormalities that can be distinguishable using right-sided VCG or measured angle markers better than the spatial QRS-T angle, the QRSd or QTc, in the absence of Taskforce ECG criteria.

  2. Peak oxygen uptake, ventilatory efficiency and QRS-duration predict event free survival in patients late after surgical repair of tetralogy of Fallot.

    PubMed

    Müller, Jan; Hager, Alfred; Diller, Gerhard-Paul; Derrick, Graham; Buys, Roselien; Dubowy, Karl-Otto; Takken, Tim; Orwat, Stefan; Inuzuka, Ryo; Vanhees, Luc; Gatzoulis, Michael; Giardini, Alessandro

    2015-10-01

    Patients with repaired tetralogy of Fallot (ToF) have an increased long-term risk of cardiovascular morbidity and mortality. Risk stratification in this population is difficult. Initial evidence suggests that cardiopulmonary exercise testing (CPET) may be helpful to risk-stratify patients with repaired ToF. We studied 875 patients after surgical repair for ToF (358 females, age 25.5 ± 11.7 year, range 7-75 years) who underwent CPET between 1999 and 2009. During a mean follow-up of 4.1 ± 2.6 years after CPET, 30 patients (3.4%) died or had sustained ventricular tachycardia (VT). 225 patients (25.7%) had other cardiac related events (emergency admission, surgery, or catheter interventions). On multivariable Cox regression-analysis, %predicted peak oxygen uptake (V˙O2 %) (p=0.001), resting QRS duration (p=0.030) and age (p<0.001) emerged as independent predictors of mortality or sustained VT. Patients with a peak V˙O2 ≤ 65% of predicted and a resting QRS duration ≥ 170 ms had a 11.4-fold risk of death or sustained VT. Ventilatory efficiency expressed as V˙E/V˙CO2 slope (p<0.001), peak V˙O2 % (p=.001), QRS duration (p=.001) and age (p=0.046) independently predicted event free survival. V˙E/V˙CO2 slope ≥ 31.0, peak V˙O2 % ≤ 65% and QRS duration ≥ 170 ms were the cut-off points with best sensitivity and specificity to detect an unfavorable outcome. CPET is an important predictive tool that may assist in the risk stratification of patients with ToF. Subjects with a poor exercise capacity in addition to a prolonged QRS duration have a substantially increased risk for death or sustained ventricular tachycardia, as well as for cardiac-related hospitalizations. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Prolonged QRS Widening After Aripiprazole Overdose.

    PubMed

    Mazer-Amirshahi, Maryann; Porter, Robert; Dewey, Kayla

    2018-05-05

    Aripiprazole is an atypical antipsychotic with a long half-life. Overdose can result in protracted somnolence and cardiac disturbances, particularly QT interval prolongation. This is a single case report of a 14-year-old boy who took an overdose of aripiprazole and developed QRS widening. A 14-year-old boy intentionally ingested 20 tablets of aripiprazole (5 mg). He was brought to the emergency department when his ingestion was discovered. The patient's vital signs were as follows: temperature, 37.7°C; heart rate, 108 beats/min; blood pressure, 138/98 mm Hg; and respirations, 16 breaths/min. Activated charcoal was administered within 90 minutes of ingestion. Initial electrocardiogram (EKG) showed sinus tachycardia, with a QRS of 138 ms and QT interval of 444 ms. QRS duration was 90 ms on an EKG performed 3 months earlier. A bolus of sodium bicarbonate was administered, and the patient was transferred to the pediatric intensive care unit. Repeat EKG demonstrated a QRS of 156 ms, and a sodium bicarbonate infusion was initiated. The patient continued to have QRS prolongation for the next 8 days, reaching a peak of 172 ms 3 days postingestion. Despite aggressive treatment with sodium bicarbonate, there was persistent QRS prolongation; however, the patient did not have any dysrhythmias and remained hemodynamically stable. The patient was discharged 9 days postingestion when the QRS duration normalized to 82 ms. Genetic testing revealed that the patient was a CYP2D6 poor metabolizer. This case suggests that aripiprazole toxicity may possibly be associated with QRS prolongation without associated dysrhythmias or cardiovascular compromise. In addition, toxicity may be prolonged in patients who are CYP2D6 poor metabolizers.

  4. Changes in paced signals may predict in-hospital cardiac arrest.

    PubMed

    Attin, Mina; Rosero, Spencer Z; Ding, Jimmy; Nolan, Scot; Tucker, Rebecca

    2018-01-01

    An increasing number of patients with chronic illnesses have implanted cardiac rhythm devices such as pacemakers and implantable cardioverter-defibrillators (ICDs). This study was conducted to identify potentially useful predictors of in-hospital cardiac arrest (I-HCA) within paced electrocardiogram (ECG) signals from cardiovascular patients with implanted medical devices. In this retrospective study of 17 subjects, full-disclosure ECG traces prior to the time of documented I-HCA were analyzed to determine R-R intervals and QRS durations (QRSd). Ventricular paced QRSd prolongation was observed prior to I-HCA in 10/16 (63%) subjects. QRSd was significantly greater immediately preceding cardiac arrest than during each of the 8 hours prior to cardiac arrest (P < 0.05). Heart rate changes (measured using standard deviation) within 15 minutes of cardiac arrest were significantly greater in subjects with pulseless electrical activity (PEA)/asystolic arrest compared to those with cardiac arrests due to ventricular tachycardia/ventricular fibrillation (VT/VF) (10.13 vs 3.31; P  =  0.024). Significant differences over the 8 hours preceding cardiac arrest in heart rate (74 vs 86 beats/min; P  =  0.002) and QRS duration (172 ms vs 137 ms; P < 0.001) were observed between subjects with initial rhythms of VT/VF and those with initial rhythms of PEA/asystole. Patterns of diagnostic ECG features can be extracted from the telemetry data of patients with implanted medical devices prior to adverse events including I-HCA. The detection of these significant changes might have an immediate prognostic impact on the timely treatment of some patients at risk of adverse events. © 2017 Wiley Periodicals, Inc.

  5. Detecting drug-induced prolongation of the QRS complex: New insights for cardiac safety assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cros, C., E-mail: caroline.cros@hotmail.co.uk; Skinner, M., E-mail: Matthew.Skinner@astrazeneca.com; Moors, J.

    Background: Drugs slowing the conduction of the cardiac action potential and prolonging QRS complex duration by blocking the sodium current (I{sub Na}) may carry pro-arrhythmic risks. Due to the frequency-dependent block of I{sub Na}, this study assesses whether activity-related spontaneous increases in heart rate (HR) occurring during standard dog telemetry studies can be used to optimise the detection of class I antiarrhythmic-induced QRS prolongation. Methods: Telemetered dogs were orally dosed with quinidine (class Ia), mexiletine (class Ib) or flecainide (class Ic). QRS duration was determined standardly (5 beats averaged at rest) but also prior to and at the plateau ofmore » each acute increase in HR (3 beats averaged at steady state), and averaged over 1 h period from 1 h pre-dose to 5 h post-dose. Results: Compared to time-matched vehicle, at rest, only quinidine and flecainide induced increases in QRS duration (E{sub max} 13% and 20% respectively, P < 0.01–0.001) whereas mexiletine had no effect. Importantly, the increase in QRS duration was enhanced at peak HR with an additional effect of + 0.7 ± 0.5 ms (quinidine, NS), + 1.8 ± 0.8 ms (mexiletine, P < 0.05) and + 2.8 ± 0.8 ms (flecainide, P < 0.01) (calculated as QRS at basal HR-QRS at high HR). Conclusion: Electrocardiogram recordings during elevated HR, not considered during routine analysis optimised for detecting QT prolongation, can be used to sensitise the detection of QRS prolongation. This could prove useful when borderline QRS effects are detected. Analysing during acute increases in HR could also be useful for detecting drug-induced effects on other aspects of cardiac function. -- Highlights: ► We aimed to improve detection of drug-induced QRS prolongation in safety screening. ► We used telemetered dogs to test class I antiarrhythmics at low and high heart rate. ► At low heart rate only quinidine and flecainide induced an increase in QRS duration. ► At high heart rate the effects

  6. Effect of PR interval prolongation on long-term outcomes in patients with left bundle branch block vs non-left bundle branch block morphologies undergoing cardiac resynchronization therapy.

    PubMed

    Rickard, John; Karim, Mohammad; Baranowski, Bryan; Cantillon, Daniel; Spragg, David; Tang, W H Wilson; Niebauer, Mark; Grimm, Richard; Trulock, Kevin; Wilkoff, Bruce; Varma, Niraj

    2017-10-01

    Although the influence of QRS duration (QRSd) and/or bundle branch block morphology on outcomes of cardiac resynchronization therapy (CRT) have been well studied, the effect of PR interval remains uncertain. The purpose of this study was to evaluate the impact of PR prolongation (PRp) before CRT on long-term outcomes, specifically taking into account bundle branch block morphology and QRSd. We extracted clinical data on consecutive patients undergoing CRT. Multivariate models were constructed to analyze the effect of PRp (≥200 ms) on the combined endpoint of death, heart transplant, or left ventricular assist device. Kaplan-Meier curves were constructed stratifying patients based on bundle branch block and QRSd (dichotomized by 150 ms). Of the 472 patients who met inclusion criteria, 197 (41.7%) had PR interval ≥200 ms. During follow-up (mean 5.1 ± 2.6 years) there were 214 endpoints, of which 109 (23.1%) occurred in patients with PRp. In multivariate analysis, PRp was independently associated with worsened outcomes (hazard ratio 1.34, 95% confidence interval 1.01-1.77, P = .04). When stratified by bundle branch block morphology, PRp was significantly associated with worsened outcomes (log-rank P <.001) in patients with LBBB but not in those with non-LBBB (log-rank P = .55). Among patients with LBBB, stratified by QRSd, patients without PRp had improved outcomes compared to those with PRp independent of QRSd (log-rank P <.001). PRp is an independent predictor of impaired long-term outcome after CRT among patients with LBBB but not in non-LBBB patients. Notably, among LBBB patients, PRp is a more important predictor than QRSd in assessing long-term outcomes. Copyright © 2017. Published by Elsevier Inc.

  7. Fragmented QRS in patients with systemic lupus erythematosus.

    PubMed

    Demır, Kenan; Avcı, Ahmet; Yılmaz, Sema; Demır, Tarık; Ersecgın, Ahmet; Altunkeser, Bulent Behlul

    2014-08-01

    Systemic lupus erythematosus (SLE) is a systemic autoimmune disease with a variety of clinical features. Cardiac involvement is present in more than half of the patients with SLE. Fragmentation of QRS (fQRS) is presumed marker of cardiovascular risk and has not been previously evaluated in SLE. A total of 56 women previously diagnosed with SLE were recruited. In addition, a control group consisting of 51 healthy people was formed. QRS complexes were also evaluated in terms of fragmentations. All patients with SLE and control subjects underwent transthoracic echocardiographic examination. Erythrocyte sedimentation rate and C-reactive protein levels were also obtained. Frequency of fQRS was higher in patients with SLE (41% vs. 21%, p = 0.03). Left ventricular posterior wall thickness and mass index were higher in the patients with SLE. CRP levels and age were significantly higher, and disease duration was significantly longer in the fQRS(+) group (p = 0.02, 0.01, and 0.006, respectively). A careful cardiovascular evaluation and follow-up is essential to continuously improve survival in SLE. For this purpose, fQRS may be used for the early detection in patients with SLE.

  8. Multipoint Pacing versus conventional ICD in Patients with a Narrow QRS complex (MPP Narrow QRS trial): study protocol for a pilot randomized controlled trial.

    PubMed

    Gasparini, Maurizio; Galimberti, Paola; Bragato, Renato; Ghio, Stefano; Raineri, Claudia; Landolina, Maurizio; Chieffo, Enrico; Lunati, Maurizio; Mulargia, Ederina; Proclemer, Alessandro; Facchin, Domenico; Rordorf, Roberto; Vicentini, Alessandro; Marcantoni, Lina; Zanon, Francesco; Klersy, Catherine

    2016-12-03

    Despite an intensive search for predictors of the response to cardiac resynchronization therapy (CRT), the QRS duration remains the simplest and most robust predictor of a positive response. QRS duration of ≥ 130 ms is considered to be a prerequisite for CRT; however, some studies have shown that CRT may also be effective in heart failure (HF) patients with a narrow QRS (<130 ms). Since CRT can now be performed by pacing the left ventricle from multiple vectors via a single quadripolar lead, it is possible that multipoint pacing (MPP) might be effective in HF patients with a narrow QRS. This article reports the design of the MPP Narrow QRS trial, a prospective, randomized, multicenter, controlled feasibility study to investigate the efficacy of MPP using two LV pacing vectors in patients with a narrow QRS complex (100-130 ms). Fifty patients with a standard ICD indication will be enrolled and randomized (1:1) to either an MPP group or a Standard ICD group. All patients will undergo a low-dose dobutamine stress echo test and only those with contractile reserve will be included in the study and randomized. The primary endpoint will be the percentage of patients in each group that have reverse remodeling at 12 months, defined as a reduction in left ventricular end-systolic volume (LVESV) of >15% from the baseline. This feasibility study will determine whether MPP improves reverse remodeling, as compared with standard ICD, in HF patients who have a narrow QRS complex (100-130 ms). ClinicalTrials.gov, NCT02402816 . Registered on 25 March 2015.

  9. [Influence of the duration of recording in the reproducibility of the signal averaged electrocardiogram].

    PubMed

    Copie, X; Blankoff, I; Hnatkova, K; Fei, L; Camm, A J; Malik, M

    1996-06-01

    The authors studied the possibility of improving the reproducibility of the signal averaged ECG by increasing the number of averaged QRS complexes. One hundred patients were included in the study. In each cases, 400 QRS complexes were recorded on twice, consecutively, in strictly identical conditions. During each recording, the total duration of the amplified and averaged QRS complex (tQRS), the duration of the terminal signal below 40 microV (LAS) and the root mean square of the amplitude of the last 40 ms (RMS) were determined for 100, 200, 300 and 400 recorded QRS complexes. The presence of late potentials was defined as the positivity of two of the following criteria: tQRS > 114 ms, LAS > 38 ms, RMS < 20 microV. The number of contradictory diagnostic conclusions between two successive recordings of the same duration decreased progressively with the number of averaged QRS complexes: 10 for 100 QRS, 10 for 200 QRS, 9 for 300 QRS and 6 for 400 QRS complexes, but this improvement was not statistically significant. The absolute differences of tQRS and RMS between two successive recordings of the same duration were statistically different for the four durations of recording (p = 0.05) and there was a tendency towards statistical significance for LAS (p = 0.09). The best quantitative reproducibility of the 3 parameters was obtained with the recording of 300 QRS complexes. In conclusion, the reproducibility of the signal averaged ECG is improved when the number of average QRS complexes is increased. The authors' results suggests that reproducibility this is optimal with the amplification and averaging of 300 QRS complexes.

  10. Analysis of the QRS complex for apnea-bradycardia characterization in preterm infants

    PubMed Central

    Altuve, Miguel; Carrault, Guy; Cruz, Julio; Beuchée, Alain; Pladys, Patrick; Hernandez, Alfredo I.

    2009-01-01

    This work presents an analysis of the information content of new features derived from the electrocardiogram (ECG) for the characterization of apnea-bradycardia events in preterm infants. Automatic beat detection and segmentation methods have been adapted to the ECG signals from preterm infants, through the application of two evolutionary algorithms. ECG data acquired from 32 preterm infants with persistent apnea-bradycardia have been used for quantitative evaluation. The adaptation procedure led to an improved sensitivity and positive predictive value, and a reduced jitter for the detection of the R-wave, QRS onset, QRS offset, and iso-electric level. Additionally, time series representing the RR interval, R-wave amplitude and QRS duration, were automatically extracted for periods at rest, before, during and after apnea-bradycardia episodes. Significant variations (p<0.05) were observed for all time-series when comparing the difference between values at rest versus values just before the bradycardia event, with the difference between values at rest versus values during the bradycardia event. These results reveal changes in the R-wave amplitude and QRS duration, appearing at the onset and termination of apnea-bradycardia episodes, which could be potentially useful for the early detection and characterization of these episodes. PMID:19963984

  11. A new method for QRS detection in ECG signals using QRS-preserving filtering techniques.

    PubMed

    Sharma, Tanushree; Sharma, Kamalesh K

    2018-03-28

    Detection of QRS complexes in ECG signals is required for various purposes such as determination of heart rate, feature extraction and classification. The problem of automatic QRS detection in ECG signals is complicated by the presence of noise spectrally overlapping with the QRS frequency range. As a solution to this problem, we propose the use of least-squares-optimisation-based smoothing techniques that suppress the noise peaks in the ECG while preserving the QRS complexes. We also propose a novel nonlinear transformation technique that is applied after the smoothing operations, which equalises the QRS amplitudes without boosting the supressed noise peaks. After these preprocessing operations, the R-peaks can finally be detected with high accuracy. The proposed technique has a low computational load and, therefore, it can be used for real-time QRS detection in a wearable device such as a Holter monitor or for fast offline QRS detection. The offline and real-time versions of the proposed technique have been evaluated on the standard MIT-BIH database. The offline implementation is found to perform better than state-of-the-art techniques based on wavelet transforms, empirical mode decomposition, etc. and the real-time implementation also shows improved performance over existing real-time QRS detection techniques.

  12. QRS analysis using wavelet transformation for the prediction of response to cardiac resynchronization therapy: a prospective pilot study.

    PubMed

    Vassilikos, Vassilios P; Mantziari, Lilian; Dakos, Georgios; Kamperidis, Vasileios; Chouvarda, Ioanna; Chatzizisis, Yiannis S; Kalpidis, Panagiotis; Theofilogiannakos, Efstratios; Paraskevaidis, Stelios; Karvounis, Haralambos; Mochlas, Sotirios; Maglaveras, Nikolaos; Styliadis, Ioannis H

    2014-01-01

    Wider QRS and left bundle branch block morphology are related to response to cardiac resynchronization therapy (CRT). A novel time-frequency analysis of the QRS complex may provide additional information in predicting response to CRT. Signal-averaged electrocardiograms were prospectively recorded, before CRT, in orthogonal leads and QRS decomposition in three frequency bands was performed using the Morlet wavelet transformation. Thirty eight patients (age 65±10years, 31 males) were studied. CRT responders (n=28) had wider baseline QRS compared to non-responders and lower QRS energies in all frequency bands. The combination of QRS duration and mean energy in the high frequency band had the best predicting ability (AUC 0.833, 95%CI 0.705-0.962, p=0.002) followed by the maximum energy in the high frequency band (AUC 0.811, 95%CI 0.663-0.960, p=0.004). Wavelet transformation of the QRS complex is useful in predicting response to CRT. © 2013.

  13. Electrocardiographic signal-averaging during atrial pacing and effect of cycle length on the terminal QRS in patients with and without inducible ventricular tachycardia.

    PubMed

    Kremers, M S; Black, W H; Lange, R; Wells, P J; Solo, M

    1990-11-01

    Electrocardiographic signal-averaging during sinus rhythm (61 to 99 beats/min) and atrial pacing (100 to 171 beats/min) were performed to determine the effect of heart rate on late potentials in 15 patients without (group 1) and 7 patients with (group 2) inducible sustained ventricular tachycardia (VT). In sinus rhythm (79 +/- 12 vs 77 +/- 12 beats/min, difference not significant), the duration of the low-amplitude signal less than 40 microV was longer in group 2 than group 1 (43 +/- 21 vs 26 +/- 8 ms, p = 0.034) and more patients had late potentials (57 vs 7%, p = 0.021), but QRS duration (121 +/- 32 vs 98 +/- 19 ms) and terminal voltage (33 +/- 33 vs 50 +/- 26 ms) were not significantly different. With atrial pacing in group 1 (128 +/- 16 beats/min), 3 patients developed a simultaneous decrease in terminal voltage and an increase in terminal QRS duration consistent with a late potential, but mean total and terminal durations were unchanged. Terminal voltage increased (50 +/- 26 to 59 +/- 40) but not significantly. With atrial pacing in group 2 (119 +/- 12 beats/min) all patients either had a late potential or developed a simultaneous decrease in terminal voltage and an increase in terminal QRS duration (p = 0.001 vs group 1). Root mean square (p = 0.001 vs group 1). Root mean square voltage decreased (33 +/- 23 to 22 +/- 23) and became significantly different from group 1 (p = 0.017). Mean QRS duration, root mean square terminal voltage and low-amplitude terminal QRS duration, however, were unchanged.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. The value of electrocardiography for differential diagnosis in wide QRS complex tachycardia.

    PubMed

    Sousa, Pedro A; Pereira, Salomé; Candeias, Rui; de Jesus, Ilídio

    2014-03-01

    Correct diagnosis in wide QRS complex tachycardia remains a challenge. Differential diagnosis between ventricular and supraventricular tachycardia has important therapeutic and prognostic implications, and although data from clinical history and physical examination may suggest a particular origin, it is the 12-lead surface electrocardiogram that usually enables this differentiation. Since 1978, various electrocardiographic criteria have been proposed for the differential diagnosis of wide complex tachycardias, particularly the presence of atrioventricular dissociation, and the axis, duration and morphology of QRS complexes. Despite the wide variety of criteria, diagnosis is still often difficult, and errors can have serious consequences. To reduce such errors, several differential diagnosis algorithms have been proposed since 1991. However, in a small percentage of wide QRS tachycardias the diagnosis remains uncertain and in these the wisest decision is to treat them as ventricular tachycardias. The authors' objective was to review the main electrocardiographic criteria and differential diagnosis algorithms of wide QRS tachycardia. Copyright © 2012 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  15. Clinical significance of fragmented QRS complexes or J waves in patients with idiopathic ventricular arrhythmias.

    PubMed

    Seong, Choong Sil; Gwag, Hye Bin; Hwang, Jin Kyung; Park, Seung Jung; Park, Kyoung-Min; Kim, June Soo; On, Young Keun

    2018-01-01

    Idiopathic ventricular fibrillation (IVF) can cause sudden cardiac death. Previous studies have reported that J waves and fragmented QRS complexes (f-QRS) are arrhythmogenic markers and predictors of cardiac events. We evaluated the prevalence and clinical significance of J waves and f-QRS in patients with IVF. We studied 81 patients who received an implantable cardioverter defibrillator (ICD) due to IVF between October 1999 and June 2015. We assessed the prevalence of J waves and f-QRS using electrocardiograms (ECGs). Patients were classified into three groups: J wave group (n = 35), f-QRS group (n = 20), or normal ECG group (n = 26). The control group included 81 subjects without heart disease who were matched for age, sex, and race. We compared syncope, sudden cardiac arrest, and appropriate ICD shock between the three groups. The follow-up duration was 4.1 years. J waves and f-QRS were more frequent in patients with IVF than in control subjects (43.2%, 21% vs. 24.7%, 19.7%, P < 0.001). Out of the three groups, clinical cardiac events were most frequent in the f-QRS group (50% vs. 45.7% vs. 11.5%, P = 0.028). A comparison of the combined group of J wave and f-QRS versus the normal ECG group revealed that the combined group had a higher frequency of clinical cardiac events than the normal ECG group (47.3% vs. 11.5%, respectively, P = 0.009). Patients with IVF had higher prevalence of f-QRS or J waves. And patients with f-QRS or J waves were at higher risk of recurrent ventricular fibrillation.

  16. Relationship between a fragmented QRS and microalbuminuria in patients with type 2 diabetes mellitus.

    PubMed

    Cetin, Sukru; Yıldız, Suleyman Sezai; Mazı, Emrah Erkan; Keskin, Kudret; Cetinkal, Gokhan; Gurdal, Ahmet; Karabay, Umut; Orta Kilickesmez, Kadriye

    2017-11-01

    Microalbuminuria (MAU), a complication of diabetes, is closely related to cardiovascular events. A fragmented QRS (fQRS) in the electrocardiogram (ECG) was found to be strongly associated to cardiovascular morbidity and mortality. The aim of this study was to assess the association between a fQRS and MAU in patients with type 2 diabetes mellitus (T2DM). One hundred and twenty-seven patients (mean age, 50.49 years; 44.01% male) with T2DM of at least six months duration and at least two urine albumin/creatinine ratios (ACRs) available were enrolled into the study between December 2015 and May 2016. All patients underwent ECG and echocardiography, and were taken blood and urine samples. Patients were divided into two groups according to presence of fQRS (group 1) or absence of fQRS (group 2). Both groups had similar baseline characteristics. MAU and glycosylated hemoglobin (HbA1c) levels and left ventricular end-diastolic diameter (LVEDd) were increased in patients with a fQRS in the ECG (p=0.002, p=0.02, and p=0.007, respectively). Univariate and multivariate logistic regression analysis showed MAU and an increased LVEDd to be independent risk factors for the presence of a fQRS in the ECG of T2DM patients. In this study, a fQRS was associated to MAU. In T2DM, MAU may be related to subclinical diastolic and systolic dysfunction. Copyright © 2017. Publicado por Elsevier España, S.L.U.

  17. Reduced long-term overall mortality in heart failure patients with prolonged QRS treated with CRT combined with ICD vs. heart failure patients with narrow QRS treated with ICD only.

    PubMed

    Palmisano, Pietro; Accogli, Michele; Pisanò, Ennio Carmine Luigi; Zaccaria, Maria; De Blasi, Sergio; Ponzetta, Maria Antonietta; Valsecchi, Sergio; Milanese, Giovanni; Lauretti, Maurelio; Magliari, Francesco

    2016-09-01

    It is not known whether heart failure (HF) patients with prolonged QRS who undergo cardiac resynchronization therapy combined with a defibrillator (CRT-D) have a prognostic advantage over HF patients with narrow QRS (therefore without indication for CRT) treated with an implantable cardioverter defibrillator (ICD) only. The aim of this study was to compare the long-term mortality of a group of HF patients with prolonged QRS receiving CRT-D with that of a similar group of patients with narrow QRS receiving ICD only. A total of 312 patients (mean age 66 ± 13 years; 84% male, mean left ventricular ejection fraction 25 ± 4%, mean New York Heart Association class 2.6 ± 0.5) were included in the analysis. Of these, 138 with a QRS complex duration ≥120 ms received a CRT-D. During follow-up, the time and cause of death were assessed. During a median follow-up of 46 months, CRT-D patients showed significantly lower overall mortality (P = 0.038). Compared with patients receiving ICD only, CRT-D patients showed lower HF mortality (P = 0.003). Coronary mortality, non-cardiac mortality, and sudden mortality were similar in both groups (all P > 0.05). A positive response to CRT was an independent predictor of reduced mortality on multivariate analysis (hazard ratio: 0.27; P = 0.047). In HF patients treated with ICD, the subgroup of patients with prolonged QRS who receive CRT-D displays better long-term survival than narrow QRS ICD recipients, owing to their reduced HF mortality. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  18. Cardiac-resynchronization therapy in heart failure with a narrow QRS complex.

    PubMed

    Ruschitzka, Frank; Abraham, William T; Singh, Jagmeet P; Bax, Jeroen J; Borer, Jeffrey S; Brugada, Josep; Dickstein, Kenneth; Ford, Ian; Gorcsan, John; Gras, Daniel; Krum, Henry; Sogaard, Peter; Holzmeister, Johannes

    2013-10-10

    Cardiac-resynchronization therapy (CRT) reduces morbidity and mortality in chronic systolic heart failure with a wide QRS complex. Mechanical dyssynchrony also occurs in patients with a narrow QRS complex, which suggests the potential usefulness of CRT in such patients. We conducted a randomized trial involving 115 centers to evaluate the effect of CRT in patients with New York Heart Association class III or IV heart failure, a left ventricular ejection fraction of 35% or less, a QRS duration of less than 130 msec, and echocardiographic evidence of left ventricular dyssynchrony. All patients underwent device implantation and were randomly assigned to have CRT capability turned on or off. The primary efficacy outcome was the composite of death from any cause or first hospitalization for worsening heart failure. On March 13, 2013, the study was stopped for futility on the recommendation of the data and safety monitoring board. At study closure, the 809 patients who had undergone randomization had been followed for a mean of 19.4 months. The primary outcome occurred in 116 of 404 patients in the CRT group, as compared with 102 of 405 in the control group (28.7% vs. 25.2%; hazard ratio, 1.20; 95% confidence interval [CI], 0.92 to 1.57; P=0.15). There were 45 deaths in the CRT group and 26 in the control group (11.1% vs. 6.4%; hazard ratio, 1.81; 95% CI, 1.11 to 2.93; P=0.02). In patients with systolic heart failure and a QRS duration of less than 130 msec, CRT does not reduce the rate of death or hospitalization for heart failure and may increase mortality. (Funded by Biotronik and GE Healthcare; EchoCRT ClinicalTrials.gov number, NCT00683696.).

  19. High Frequency QRS ECG Accurately Detects Cardiomyopathy

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd T.; Arenare, Brian; Poulin, Gregory; Moser, Daniel R.; Delgado, Reynolds

    2005-01-01

    High frequency (HF, 150-250 Hz) analysis over the entire QRS interval of the ECG is more sensitive than conventional ECG for detecting myocardial ischemia. However, the accuracy of HF QRS ECG for detecting cardiomyopathy is unknown. We obtained simultaneous resting conventional and HF QRS 12-lead ECGs in 66 patients with cardiomyopathy (EF = 23.2 plus or minus 6.l%, mean plus or minus SD) and in 66 age- and gender-matched healthy controls using PC-based ECG software recently developed at NASA. The single most accurate ECG parameter for detecting cardiomyopathy was an HF QRS morphological score that takes into consideration the total number and severity of reduced amplitude zones (RAZs) present plus the clustering of RAZs together in contiguous leads. This RAZ score had an area under the receiver operator curve (ROC) of 0.91, and was 88% sensitive, 82% specific and 85% accurate for identifying cardiomyopathy at optimum score cut-off of 140 points. Although conventional ECG parameters such as the QRS and QTc intervals were also significantly longer in patients than controls (P less than 0.001, BBBs excluded), these conventional parameters were less accurate (area under the ROC = 0.77 and 0.77, respectively) than HF QRS morphological parameters for identifying underlying cardiomyopathy. The total amplitude of the HF QRS complexes, as measured by summed root mean square voltages (RMSVs), also differed between patients and controls (33.8 plus or minus 11.5 vs. 41.5 plus or minus 13.6 mV, respectively, P less than 0.003), but this parameter was even less accurate in distinguishing the two groups (area under ROC = 0.67) than the HF QRS morphologic and conventional ECG parameters. Diagnostic accuracy was optimal (86%) when the RAZ score from the HF QRS ECG and the QTc interval from the conventional ECG were used simultaneously with cut-offs of greater than or equal to 40 points and greater than or equal to 445 ms, respectively. In conclusion 12-lead HF QRS ECG employing

  20. Fragmented QRS and prediction of paroxysmal atrial fibrillation episodes

    PubMed Central

    Temiz, Ahmet; Gazi, Emine; Güngör, Ömer; Altun, Burak; Barutcu, Ahmet; Bekler, Adem; Tan, Yusuf Ziya; Ozcan, Sedat; Yener, Ali Ümit; Kurt, Tolga

    2014-01-01

    Objective: Prior studies have demonstrated the relationship between cardiovascular diseases and fragmented QRS (fQRS). fQRS was also associated with ventricular arrhythmias. Our objective was to find out the relationship between fQRS and paroxysmal atrial fibrillation (PAF). Method: A total of 301 patients without overt structural heart disease were prospectively included in the study. Patients were divided in to 2 groups according to presence of fQRS. Multivariate logistic regression analysis was used to assess the predictive value of fQRS for predicting PAF. Results: One hundred and three patients had fQRS. Patients with fQRS were older (53±16.8 vs 45.3±17.2, p<0.001), with larger left atrium (LA) (33.2±5.9 vs 30.1±5.9 mm, p=0.001), with thicker interventricular septum (IVS) (10.2±1.9 vs 9.5±2.3 mm, p=0.032), more diabetic (19.8 vs 10.6%, p=0.029) and have more PAF episodes (22.3 vs 4.1%, p<0.001) in comparison with patients without fQRS. fQRS was an independent predictor of detecting PAF episode (odds ratio, 9.69; 95% confidence interval, 2.46-38.15, p=0.001). Hypertension and diabetes mellitus were also predictive. Conclusion: The presence of fQRS independently predicted PAF episodes in holter monitoring (HM). Further studies are needed to clarify the clinical implications of this finding. PMID:25097533

  1. Aviation System Analysis Capability (ASAC) Quick Response System (QRS) Test Report

    NASA Technical Reports Server (NTRS)

    Roberts, Eileen; Villani, James A.; Ritter, Paul

    1997-01-01

    This document is the Aviation System Analysis Capability (ASAC) Quick Response System (QRS) Test Report. The purpose of this document is to present the results of the QRS unit and system tests in support of the ASAC QRS development effort. This document contains an overview of the project background and scope, defines the QRS system and presents the additions made to the QRS this year, explains the assumptions, constraints, and approach used to conduct QRS Unit and System Testing, and presents the schedule used to perform QRS Testing. The document also presents an overview of the Logistics Management Institute (LMI) Test Facility and testing environment and summarizes the QRS Unit and System Test effort and results.

  2. Usefulness of Derived Frank Lead Parameters in Screening for Coronary Artery Disease and Cardiomyopathy

    NASA Technical Reports Server (NTRS)

    DePalma, J. L.; Schlegel, T. T.; Arenare, B.; Greco, E. C.; Starc, V.; Rahman, M. A.; Delgado, R.

    2007-01-01

    We investigated the accuracy of several known as well as newly-introduced derived Frank-lead ECG parameters in differentiating healthy individuals from patients with obstructive coronary artery disease (CAD) and cardiomyopathy (CM). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. The following derived Frank lead parameters were studied for their accuracy in detecting CAD and CM: the spatial ventricular gradient (VG), including its beat-to-beat coefficient of variability (VG CV); the spatial mean QRS (SM-QRS) and T-waves (SM-T) and their beat-to-beat coefficients of variability; the spatial ventricular activation time (VAT); the mean and maximum spatial QRS-T angles; and standard late potentials parameters (RMS40, fQRSD and LAS). Several of these parameters were accurate in discriminating between the control group and both diseased groups at p less than 0.0001. For example the fQRSD, VG CV, mean spatial QRS-T angle and VG minus SM-QRS (which is similar to the SM-T) had retrospective areas under the ROC curve of 0.78, 0.78, 0.80, and 0.84 (CAD vs. controls) and 0.93, 0.88, 0.98 and 0.99 (CM vs. controls), respectively. The single most effective parameter in discriminating between the CAD and CM groups was the spatial VAT (44 plus or minus 5.8 vs. 53 plus or minus 9.9 ms, p less than 0.0001), with an area under the ROC curve of 0.80. Since subsequent prospective analyses using new groups of patients and healthy subjects have yielded only slightly less accurate results, we conclude that derived Frank-lead parameters show great promise for potentially contributing to the development of a rapid and inexpensive resting ECG-based screening test for heart disease.

  3. Distribution and determinants of QRS rotation of black and white persons in the general population.

    PubMed

    Prineas, Ronald J; Zhang, Zhu-Ming; Stevens, Cladd E; Soliman, Elsayed Z

    The prevalence and determinants of QRS transition zones are not well established. We examined the distributions of Normal, clockwise (CW) and counterclockwise (CCW)) QRS transition zones and their relations to disease, body size and demographics in 4624 black and white men and women free of cardiovascular disease and major ECG abnormalities enrolled in the NHANES-III survey. CW transition zones were least observed (6.2%) and CCW were most prevalent (60.1%) with Normal in an intermediate position (33.7%). In multivariable logistic regression analysis, the adjusted, significant predictors for CCW compared to Normal were a greater proportion of blacks and women, fewer thin people (BMI<20, thin), a greater ratio of chest depth to chest width, and an LVMass index <80g. By contrast, CW persons were older, had larger QRS/T angles, smaller ratio of chest depth to chest width, had a greater proportion of subjects with low voltage QRS, more pulmonary disease, a greater proportion with high heart rates, shorter QRS duration and were more obese (BMI≥30). Normal rather than being the most prevalent transition zone was intermediate in frequency between the most frequently encountered CCW and the least frequently encountered transition zone CW. Differences in the predictors of CW and CCW exist. This requires further investigation to examine how far these differences explain the differences in the published prognostic differences between CW and CCW. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Mobile/android application for QRS detection using zero cross method

    NASA Astrophysics Data System (ADS)

    Rizqyawan, M. I.; Simbolon, A. I.; Suhendra, M. A.; Amri, M. F.; Kusumandari, D. E.

    2018-03-01

    In automatic ECG signal processing, one of the main topics of research is QRS complex detection. Detecting correct QRS complex or R peak is important since it is used to measure several other ECG metrics. One of the robust methods for QRS detection is Zero Cross method. This method uses an addition of high-frequency signal and zero crossing count to detect QRS complex which has a low-frequency oscillation. This paper presents an application of QRS detection using Zero Cross algorithm in the Android-based system. The performance of the algorithm in the mobile environment is measured. The result shows that this method is suitable for real-time QRS detection in a mobile application.

  5. Atrial Premature Depolarization-Induced Changes in QRS and T Wave Morphology on Resting Electrocardiograms in Horses.

    PubMed

    Broux, B; De Clercq, D; Decloedt, A; Van Der Vekens, N; Verheyen, T; Ven, S; Pardon, B; van Loon, G

    2016-07-01

    The electrocardiographic differentiation between atrial (APDs) and ventricular (VPDs) premature depolarizations is important. P wave prematurity and normal QRS and T wave morphology generally are used as discriminating criteria for APDs. The aim of this study was to determine whether P, Q, R, S, and T wave amplitude, PQ interval, QRS and P wave duration and P and T wave morphology differ between APDs and sinus beats. To determine the relationship between the RR coupling interval and the change in S wave amplitude between sinus beats and APDs. Case-control study. From a modified base-apex configuration of 30 horses with APDs at rest, sinus beat and APD associated preceding RR interval, P, PQ and QRS duration and P, R, S, and T wave amplitudes were measured. Linear mixed models and logistic regression were used to determine the effect of APDs on the ECG variables studied. In comparison to sinus beats, APDs were associated with a significant (P < .001) change in P amplitude (-0.03 ± 0.01 mV) and increase in S (0.20 ± 0.02 mV) and T (0.08 ± 0.03 mV) amplitude. PQ (-20.3 ± 5.2 ms) and RR (-519 ± 14 ms) interval and P duration (-21.1 ± 3.0 ms) decreased (P < .001). APDs were significantly associated with a singular positive P wave (OR: 11.0, P < .001) and were more likely to have a monophasic positive T wave (OR: 9.2, P < .001). A smaller RR coupling interval was associated with an increased relative difference in S amplitude (P < .01). Atrial premature depolarizations may lead to changes in QRS and T wave morphology. Knowledge of these changes is important to avoid interpreting certain APDs as VPDs. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  6. Detection of segments with fetal QRS complex from abdominal maternal ECG recordings using support vector machine

    NASA Astrophysics Data System (ADS)

    Delgado, Juan A.; Altuve, Miguel; Nabhan Homsi, Masun

    2015-12-01

    This paper introduces a robust method based on the Support Vector Machine (SVM) algorithm to detect the presence of Fetal QRS (fQRS) complexes in electrocardiogram (ECG) recordings provided by the PhysioNet/CinC challenge 2013. ECG signals are first segmented into contiguous frames of 250 ms duration and then labeled in six classes. Fetal segments are tagged according to the position of fQRS complex within each one. Next, segment features extraction and dimensionality reduction are obtained by applying principal component analysis on Haar-wavelet transform. After that, two sub-datasets are generated to separate representative segments from atypical ones. Imbalanced class problem is dealt by applying sampling without replacement on each sub-dataset. Finally, two SVMs are trained and cross-validated using the two balanced sub-datasets separately. Experimental results show that the proposed approach achieves high performance rates in fetal heartbeats detection that reach up to 90.95% of accuracy, 92.16% of sensitivity, 88.51% of specificity, 94.13% of positive predictive value and 84.96% of negative predictive value. A comparative study is also carried out to show the performance of other two machine learning algorithms for fQRS complex estimation, which are K-nearest neighborhood and Bayesian network.

  7. Comparison of the calculation QRS angle for bundle branch block detection

    NASA Astrophysics Data System (ADS)

    Goeirmanto, L.; Mengko, R.; Rajab, T. L.

    2016-04-01

    QRS angle represent condition of blood circulation in the heart. Normally QRS angle is between -30 until 90 degree. Left Axis Defiation (LAD) and Right Axis Defiation (RAD) are abnormality conditions that lead to Bundle Branch Block. QRS angle is calculated using common method from physicians and compared to mathematical method using difference amplitudos and difference areas. We analyzed the standard 12 lead electrocardiogram data from MITBIH physiobank database. All methods using lead I and lead avF produce similar QRS angle and right QRS axis quadrant. QRS angle from mathematical method using difference areas is close to common method from physician. Mathematical method using difference areas can be used as a trigger for detecting heart condition.

  8. Analysis of the temporal regression of the QRS widening induced by bupivacaine after Intralipid administration. Study in an experimental porcine model.

    PubMed

    Zaballos, M; Sevilla, R; González, J; Callejo, D; de Diego, C; Almendral, J; Quintela, O; Anadón, M J

    2016-01-01

    The principal mechanism of cardiac toxicity of bupivacaine relates to the blockade of myocardial sodium channels, which leads to an increase in the QRS duration. Recently, experimental studies suggest that lipid emulsion is effective in reversing bupivacaine cardiac toxicity. We aimed to evaluate the temporal evolution of the QRS widening induced by bupivacaine with the administration of Intralipid. Twelve pigs were anesthetized with intravenous sodium thiopental 5mg kg(-1) and sevoflurane 1 MAC (2.6%). Femoral artery and vein were canalized for invasive monitoring, analysis of blood gases and determination of bupivacaine levels. After instrumentation and monitoring, a bupivacaine bolus of 4-6 mg kg(-1) was administered in order to induce a 150% increase in QRS duration (defined as the toxic point). The pigs were randomized into two groups of six individuals. Intralipid group (IL) received 1.5 mL kg(-1)of IL over one minute, followed by an infusion of 0.25 mL kg min(-1). Control group (C) received the same volume of a saline solution. The electrocardiographic parameters were recorded, and blood samples were taken after bupivacaine and 1, 5, 10 and 30 minutes after Intralipid/saline administration. Bupivacaine (4.33±0.81 mg/kg in IL group and 4.66±1.15 mg/kg in C group) induced similar electrocardiographic changes in both groups; mean maximal percent increase in QRS interval was 184±62% in IL group, and 230±56% in control group (NS). Lipid administration reversed the QRS widening previously impaired by bupivacaine. After ten minutes of the administration of IL, the mean QRS interval decreased to 132±56% vs. 15±76% relative to the maximum widening induced by bupivacaine, in IL and C group, respectively. Intralipid reversed the lengthening of QRS interval induced by the injection of bupivacaine. Time to normalization of electrocardiographic parameters can last more than 10 minutes. While the phenomena of cardiac toxicity persist, resuscitation measures and

  9. High frequency QRS ECG predicts ischemic defects during myocardial perfusion imaging

    NASA Technical Reports Server (NTRS)

    2004-01-01

    Changes in high frequency QRS components of the electrocardiogram (HF QRS ECG) (150-250 Hz) are more sensitive than changes in conventional ST segments for detecting myocardial ischemia. We investigated the accuracy of 12-lead HF QRS ECG in detecting ischemia during adenosine tetrofosmin myocardial perfusion imaging (MPI). 12-lead HF QRS ECG recordings were obtained from 45 patients before and during adenosine technetium-99 tetrofosmin MPI tests. Before the adenosine infusions, recordings of HF QRS were analyzed according to a morphological score that incorporated the number, type and location of reduced amplitude zones (RAZs) present in the 12 leads. During the adenosine infusions, recordings of HF QRS were analyzed according to the maximum percentage changes (in both the positive and negative directions) that occurred in root mean square (RMS) voltage amplitudes within the 12 leads. The best set of prospective HF QRS criteria had a sensitivity of 94% and a specificity of 83% for correctly identifying the MPI result. The sensitivity of simultaneous ST segment changes (18%) was significantly lower than that of any individual HF QRS criterion (P less than 0.00l). Analysis of 12-lead HF QRS ECG is highly sensitive and specific for detecting ischemic perfusion defects during adenosine MPI stress tests and significantly more sensitive than analysis of conventional ST segments.

  10. High frequency QRS ECG predicts ischemic defects during myocardial perfusion imaging

    NASA Technical Reports Server (NTRS)

    Rahman, Atiar

    2006-01-01

    Background: Changes in high frequency QRS components of the electrocardiogram (HF QRS ECG) (150-250 Hz) are more sensitive than changes in conventional ST segments for detecting myocardial ischemia. We investigated the accuracy of 12-lead HF QRS ECG in detecting ischemia during adenosine tetrofosmin myocardial perfusion imaging (MPI). Methods and Results: 12-lead HF QRS ECG recordings were obtained from 45 patients before and during adenosine technetium-99 tetrofosmin MPI tests. Before the adenosine infusions, recordings of HF QRS were analyzed according to a morphological score that incorporated the number, type and location of reduced amplitude zones (RAZs) present in the 12 leads. During the adenosine infusions, recordings of HF QRS were analyzed according to the maximum percentage changes (in both the positive and negative directions) that occurred in root mean square (RMS) voltage amplitudes within the 12 leads. The best set of prospective HF QRS criteria had a sensitivity of 94% and a specificity of 83% for correctly identifying the MPI result. The sensitivity of simultaneous ST segment changes (18%) was significantly lower than that of any individual HF QRS criterion (P<0.001). Conclusions: Analysis of 12-lead HF QRS ECG is highly sensitive and specific for detecting ischemic perfusion defects during adenosine MPI stress tests and significantly more sensitive than analysis of conventional ST segments.

  11. Sodium channel blockade with QRS widening after an escitalopram overdose.

    PubMed

    Schreffler, Susan M; Marraffa, Jeanna M; Stork, Christine M; Mackey, Jennifer

    2013-09-01

    Escitalopram is rarely associated with prolongation of the QTc interval; however, there are no reported cases of QRS complex widening associated with escitalopram overdose. We report a case of a patient who presented with both QRS complex widening and QTc interval prolongation after an escitalopram overdose. A 16-year-old girl presented to the emergency department after ingestion of escitalopram, tramadol/acetaminophen, and hydrocodone/acetaminophen. Laboratory results were significant for 4-hour acetaminophen 21.1 μg/mL. Serum electrolytes including potassium, magnesium, and calcium were all normal. Initial electrocardiogram (ECG) revealed a widened QRS with an incomplete right bundle branch pattern. After administration of 100-mEq sodium bicarbonate, a repeat ECG revealed narrowing of the QRS complex and a prolonged QTc interval. Magnesium sulfate 2 g intravenous and sodium bicarbonate drip were initiated. A repeat ECG, 1 hour after the second, revealed normalization of the QRS complex and QTc interval. Prolongation of the QTc interval is an expected effect of escitalopram. Both escitalopram and citalopram are metabolized to the cardiotoxic metabolite S-didesmethylcitalopram and didesmethylcitalopram, respectively, which have been implicated in numerous cardiac abnormalities including widening of the QRS complex. Although never previously described with escitalopram, this mechanism provides a reasonable explanation for the QRS complex widening and incomplete right bundle branch block that occurred in our patient. Both QRS complex widening and QTc interval prolongation should be monitored in cases of escitalopram and citalopram overdoses.

  12. Summation and Cancellation Effects on QRS and ST-Segment Changes Induced by Simultaneous Regional Myocardial Ischemia.

    PubMed

    Vives-Borrás, Miquel; Jorge, Esther; Amorós-Figueras, Gerard; Millán, Xavier; Arzamendi, Dabit; Cinca, Juan

    2018-01-01

    Simultaneous ischemia in two myocardial regions is a potentially lethal clinical condition often unrecognized whose corresponding electrocardiographic (ECG) patterns have not yet been characterized. Thus, this study aimed to determine the QRS complex and ST-segment changes induced by concurrent ischemia in different myocardial regions elicited by combined double occlusion of the three main coronary arteries. For this purpose, 12 swine were randomized to combination of 5-min single and double coronary artery occlusion: Group 1: left Circumflex (LCX) and right (RCA) coronary arteries ( n = 4); Group 2: left anterior descending artery (LAD) and LCX ( n = 4) and; Group 3: LAD and RCA ( n = 4). QRS duration and ST-segment displacement were measured in 15-lead ECG. As compared with single occlusion, double LCX+RCA blockade induced significant QRS widening of about 40 ms in nearly all ECG leads and magnification of the ST-segment depression in leads V1-V3 (maximal 228% in lead V3, p < 0.05). In contrast, LAD+LCX or LAD+RCA did not induce significant QRS widening and markedly attenuated the ST-segment elevation in precordial leads (maximal attenuation of 60% in lead V3 in LAD+LCX and 86% in lead V5 in LAD+RCA, p < 0.05). ST-segment elevation in leads V7-V9 was a specific sign of single LCX occlusion. In conclusion, concurrent infero-lateral ischemia was associated with a marked summation effect of the ECG changes previously elicited by each single ischemic region. By contrast, a cancellation effect on ST-segment changes with no QRS widening was observed when the left anterior descending artery was involved.

  13. Microcontroller-based real-time QRS detection.

    PubMed

    Sun, Y; Suppappola, S; Wrublewski, T A

    1992-01-01

    The authors describe the design of a system for real-time detection of QRS complexes in the electrocardiogram based on a single-chip microcontroller (Motorola 68HC811). A systematic analysis of the instrumentation requirements for QRS detection and of the various design techniques is also given. Detection algorithms using different nonlinear transforms for the enhancement of QRS complexes are evaluated by using the ECG database of the American Heart Association. The results show that the nonlinear transform involving multiplication of three adjacent, sign-consistent differences in the time domain gives a good performance and a quick response. When implemented with an appropriate sampling rate, this algorithm is also capable of rejecting pacemaker spikes. The eight-bit single-chip microcontroller provides sufficient throughput and shows a satisfactory performance. Implementation of multiple detection algorithms in the same system improves flexibility and reliability. The low chip count in the design also favors maintainability and cost-effectiveness.

  14. QRS Detection Algorithm for Telehealth Electrocardiogram Recordings.

    PubMed

    Khamis, Heba; Weiss, Robert; Xie, Yang; Chang, Chan-Wei; Lovell, Nigel H; Redmond, Stephen J

    2016-07-01

    QRS detection algorithms are needed to analyze electrocardiogram (ECG) recordings generated in telehealth environments. However, the numerous published QRS detectors focus on clean clinical data. Here, a "UNSW" QRS detection algorithm is described that is suitable for clinical ECG and also poorer quality telehealth ECG. The UNSW algorithm generates a feature signal containing information about ECG amplitude and derivative, which is filtered according to its frequency content and an adaptive threshold is applied. The algorithm was tested on clinical and telehealth ECG and the QRS detection performance is compared to the Pan-Tompkins (PT) and Gutiérrez-Rivas (GR) algorithm. For the MIT-BIH Arrhythmia database (virtually artifact free, clinical ECG), the overall sensitivity (Se) and positive predictivity (+P) of the UNSW algorithm was >99%, which was comparable to PT and GR. When applied to the MIT-BIH noise stress test database (clinical ECG with added calibrated noise) after artifact masking, all three algorithms had overall Se >99%, and the UNSW algorithm had higher +P (98%, p < 0.05) than PT and GR. For 250 telehealth ECG records (unsupervised recordings; dry metal electrodes), the UNSW algorithm had 98% Se and 95% +P which was superior to PT (+P: p < 0.001) and GR (Se and +P: p < 0.001). This is the first study to describe a QRS detection algorithm for telehealth data and evaluate it on clinical and telehealth ECG with superior results to published algorithms. The UNSW algorithm could be used to manage increasing telehealth ECG analysis workloads.

  15. Automatic QRS complex detection using two-level convolutional neural network.

    PubMed

    Xiang, Yande; Lin, Zhitao; Meng, Jianyi

    2018-01-29

    The QRS complex is the most noticeable feature in the electrocardiogram (ECG) signal, therefore, its detection is critical for ECG signal analysis. The existing detection methods largely depend on hand-crafted manual features and parameters, which may introduce significant computational complexity, especially in the transform domains. In addition, fixed features and parameters are not suitable for detecting various kinds of QRS complexes under different circumstances. In this study, based on 1-D convolutional neural network (CNN), an accurate method for QRS complex detection is proposed. The CNN consists of object-level and part-level CNNs for extracting different grained ECG morphological features automatically. All the extracted morphological features are used by multi-layer perceptron (MLP) for QRS complex detection. Additionally, a simple ECG signal preprocessing technique which only contains difference operation in temporal domain is adopted. Based on the MIT-BIH arrhythmia (MIT-BIH-AR) database, the proposed detection method achieves overall sensitivity Sen = 99.77%, positive predictivity rate PPR = 99.91%, and detection error rate DER = 0.32%. In addition, the performance variation is performed according to different signal-to-noise ratio (SNR) values. An automatic QRS detection method using two-level 1-D CNN and simple signal preprocessing technique is proposed for QRS complex detection. Compared with the state-of-the-art QRS complex detection approaches, experimental results show that the proposed method acquires comparable accuracy.

  16. Diagnostic value of QRS and S wave variation in patients with suspicion of acute pulmonary embolism.

    PubMed

    Çağdaş, Metin; Karakoyun, Süleyman; Rencüzoğulları, İbrahim; Karabağ, Yavuz; Artaç, İnanç; İliş, Doğan; Hamideyin, Şerif; Karayol, Sibel; Çiftçi, Handan; Çınar, Tufan

    2018-03-29

    This study aimed to investigate the diagnostic value of QRS and S wave variation in patients admitted to the emergency department with suspicion of acute pulmonary embolism (APE). Computerized tomographic pulmonary angiography (CTPA) was performed in 118 consecutive patients to evaluate patients with suspected APE, and 106 subjects with appropriate electrocardiogram and CT images constituted the study population. Using CTPA, APE was diagnosed in 48.1% (n:51) of the study population. The comparison of patients with APE and those without APE revealed that increased heart rate, right axis deviation of QRS axis, complete or incomplete right bundle branch block, prominent S wave in lead D1, increased QRS duration, percentage of QRS (9,8[4,8-19,0] vs 3,8[2,7-71]; p<0,001), S wave variation (22,3[9,6-31,9] vs 4,8 [2-8]; p<0,001) and ΔS wave amplitude (1.1[0.5-1.5] vs 0.2[0.1-0.5]; p<0.001) were significantly associated with APE, but no relationship was detected with respect to the presence of atrial arrhythmias, clockwise rotation of the horizontal axis, fragmentation, ST segment deviation, T wave inversion, and S1Q3T3 and S1S2S3 patterns. The percentage of S wave variation (OR: 1072 per 1% increase, 95% CI:1011-1137) was found to be an independent predictor of APE. ΔS wave amplitude>0.5mm predicted APE with a sensitivity of 72.6% and a specificity of 74.6% (AUC:0.805, 95% CI: 0.717-0.876; p<0.001). The present study demonstrated that QRS and S wave variation could be useful electrocardiographic signs for the diagnosis of APE. Copyright © 2018. Published by Elsevier Inc.

  17. [A research on real-time ventricular QRS classification methods for single-chip-microcomputers].

    PubMed

    Peng, L; Yang, Z; Li, L; Chen, H; Chen, E; Lin, J

    1997-05-01

    Ventricular QRS classification is key technique of ventricular arrhythmias detection in single-chip-microcomputer based dynamic electrocardiogram real-time analyser. This paper adopts morphological feature vector including QRS amplitude, interval information to reveal QRS morphology. After studying the distribution of QRS morphology feature vector of MIT/BIH DB ventricular arrhythmia files, we use morphological feature vector cluster to classify multi-morphology QRS. Based on the method, morphological feature parameters changing method which is suitable to catch occasional ventricular arrhythmias is presented. Clinical experiments verify missed ventricular arrhythmia is less than 1% by this method.

  18. QRS peak detection for heart rate monitoring on Android smartphone

    NASA Astrophysics Data System (ADS)

    Pambudi Utomo, Trio; Nuryani, Nuryani; Darmanto

    2017-11-01

    In this study, Android smartphone is used for heart rate monitoring and displaying electrocardiogram (ECG) graph. Heart rate determination is based on QRS peak detection. Two methods are studied to detect the QRS complex peak; they are Peak Threshold and Peak Filter. The acquisition of ECG data is utilized by AD8232 module from Analog Devices, three electrodes, and Microcontroller Arduino UNO R3. To record the ECG data from a patient, three electrodes are attached to particular body’s surface of a patient. Patient’s heart activity which is recorded by AD8232 module is decoded by Arduino UNO R3 into analog data. Then, the analog data is converted into a voltage value (mV) and is processed to get the QRS complex peak. Heart rate value is calculated by Microcontroller Arduino UNO R3 uses the QRS complex peak. Voltage, heart rate, and the QRS complex peak are sent to Android smartphone by Bluetooth HC-05. ECG data is displayed as the graph by Android smartphone. To evaluate the performance of QRS complex peak detection method, three parameters are used; they are positive predictive, accuracy and sensitivity. Positive predictive, accuracy, and sensitivity of Peak Threshold method is 92.39%, 70.30%, 74.62% and for Peak Filter method are 98.38%, 82.47%, 83.61%, respectively.

  19. Colorado Qualistar. QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Colorado's Qualistar prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for Family…

  20. A deep learning approach for fetal QRS complex detection.

    PubMed

    Zhong, Wei; Liao, Lijuan; Guo, Xuemei; Wang, Guoli

    2018-04-20

    Non-invasive foetal electrocardiography (NI-FECG) has the potential to provide more additional clinical information for detecting and diagnosing fetal diseases. We propose and demonstrate a deep learning approach for fetal QRS complex detection from raw NI-FECG signals by using a convolutional neural network (CNN) model. The main objective is to investigate whether reliable fetal QRS complex detection performance can still be obtained from features of single-channel NI-FECG signals, without canceling maternal ECG (MECG) signals. A deep learning method is proposed for recognizing fetal QRS complexes. Firstly, we collect data from set-a of the PhysioNet/computing in Cardiology Challenge database. The sample entropy method is used for signal quality assessment. Part of the bad quality signals is excluded in the further analysis. Secondly, in the proposed method, the features of raw NI-FECG signals are normalized before they are fed to a CNN classifier to perform fetal QRS complex detection. We use precision, recall, F-measure and accuracy as the evaluation metrics to assess the performance of fetal QRS complex detection. The proposed deep learning method can achieve relatively high precision (75.33%), recall (80.54%), and F-measure scores (77.85%) compared with three other well-known pattern classification methods, namely KNN, naive Bayes and SVM. the proposed deep learning method can attain reliable fetal QRS complex detection performance from the raw NI-FECG signals without canceling MECG signals. In addition, the influence of different activation functions and signal quality assessment on classification performance are evaluated, and results show that Relu outperforms the Sigmoid and Tanh on this particular task, and better classification performance is obtained with the signal quality assessment step in this study.

  1. Total Mortality, Major Adverse Cardiac Events, and Echocardiographic-Derived Cardiac Parameters with Fragmented QRS Complex.

    PubMed

    Gong, Bojun; Li, Zicheng

    2016-07-01

    Fragmented QRS complex (fQRS), an easily evaluated noninvasive electrocardiographic parameter, is associated with worse outcomes in patients with several cardiovascular conditions. The presence of fQRS on ECG may be an indicator of myocardial damage in patients with coronary artery disease (CAD). In this article, we performed a meta-analysis in order to characterize the presence of fQRS on ECG in patients with CAD. We searched English-language randomized controlled trials involving fQRS on ECG in patients with CAD (n = 3279 patients, 12 trials). Two reviewers independently extracted data. Data on LVEF, LVESD, LVEDD, LVESV, LVEDV, total mortality, stroke, and MACE were collected. fQRS was performed a comparison with non-fQRS, calculating pooled relatives risk (RRs) and weighted mean difference (WMD), and associated 95% confidence intervals (CIs). fQRS was associated with significant increased WMD of LVEDD (WMD, 2.26; 95%CI, 0.92 to 0.36, P = 0.0009), LVESD (WMD, 2.71; 95%CI, 1.23 to 4.19, P = 0.0003), LVEDV (WMD, 31.37; 95%CI, 24.82 to 37.92, P < 0.00001), and LVESV (WMD, 28.45; 95%CI, 22.92 to 33.98, P < 0.00001). As compared to non-fQRS, fQRS increased risk of total mortality (RR, 3.09; 95%CI, 1.76 to 5.44, P < 0.0001) and MACE (RR, 2.85; 95%CI, 1.98 to 4.09, P < 0.00001) in patients with CAD. However, a decreased trend was observed for LVEF (WMD, -3.59; 95%CI, -7.05 to -0.12, P = 0.04). For the incidence of stoke, there was no difference between fQRS and non-fQRS group. Our findings indicate that fQRS is a valuable factor to predict total mortality and MACE in patients with CAD. © 2015 Wiley Periodicals, Inc.

  2. Pennsylvania Keystone STARS: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Pennsylvania's Keystone STARS prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for…

  3. Illinois Quality Counts: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Illinois' Quality Counts prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for Family…

  4. Minnesota Parent Aware: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Minnesota's Parent Aware prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for Family…

  5. Algorithm for detection the QRS complexes based on support vector machine

    NASA Astrophysics Data System (ADS)

    Van, G. V.; Podmasteryev, K. V.

    2017-11-01

    The efficiency of computer ECG analysis depends on the accurate detection of QRS-complexes. This paper presents an algorithm for QRS complex detection based of support vector machine (SVM). The proposed algorithm is evaluated on annotated standard databases such as MIT-BIH Arrhythmia database. The QRS detector obtained a sensitivity Se = 98.32% and specificity Sp = 95.46% for MIT-BIH Arrhythmia database. This algorithm can be used as the basis for the software to diagnose electrical activity of the heart.

  6. Electrical remodeling reflected by QRS and T vector changes following cardiac resynchronization therapy is related to survival in heart failure patients with left bundle branch block.

    PubMed

    Floré, V; Bartunek, J; Goethals, M; Verstreken, S; Timmermans, W; De Pauw, F; Van Bockstal, K; Vanderheyden, M

    2015-01-01

    We investigated changes in electrocardiographic spatial QRS and T vectors as markers of electrical remodeling before and after cardiac resynchronization therapy (CRT) and their association with altered outcome. In 41 patients with LBBB, ECGpost was recorded during intrinsic rhythm after interrupting CRT pacing and compared to the pre-implant ECGpre and the ECG during CRT (ECGCRT). Mean spatial angles between QRS and T vectors were determined with the Kors matrix conversion. Left ventricular ejection fraction (LVEF) was determined with nuclear isotope ventriculography before CRT implantation (LVEFpre) and at inclusion (LVEFpost). Following CRT, LVEF improved significantly from 26 ± 10 to 36 ± 14% (p=0.01). Duration of QRSpre (168 ± 15 ms) was not different from QRSpost (166 ± 15 ms). A smaller angle between QRSCRT and Tpost was related to a greater angle between Tpre and Tpost (Pearson's R -0.61 - p<0.001). During follow-up (30 ± 2 months) 9 patients (22%) died. Univariate Cox regression revealed higher mortality in the patients with lower LVEFpost (HR 1.10, p=0.01), a larger angle QRSCRTTpost (HR 1.03, p=0.03), a smaller angle QRSpreQRSpost (HR 0.97, p=0.03) and smaller angle TpreTpost (HR 0.95, p<0.01). After adjusting for LVEFpost, only smaller angle TpreTpost was associated with mortality (HR 0.96, p=0.03). Electrical remodeling can be quantified by measuring the angles between spatial QRS and T vectors before, during and after CRT. In absence of QRS duration changes, more extensive electrical remodeling is associated with a significantly better survival. QRS and T vector changes deserve further investigation to better understand the individual response to CRT. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Comparison of automated measurements of electrocardiographic intervals and durations by computer-based algorithms of digital electrocardiographs.

    PubMed

    Kligfield, Paul; Badilini, Fabio; Rowlandson, Ian; Xue, Joel; Clark, Elaine; Devine, Brian; Macfarlane, Peter; de Bie, Johan; Mortara, David; Babaeizadeh, Saeed; Gregg, Richard; Helfenbein, Eric D; Green, Cynthia L

    2014-02-01

    Automated measurements of electrocardiographic (ECG) intervals are widely used by clinicians for individual patient diagnosis and by investigators in population studies. We examined whether clinically significant systematic differences exist in ECG intervals measured by current generation digital electrocardiographs from different manufacturers and whether differences, if present, are dependent on the degree of abnormality of the selected ECGs. Measurements of RR interval, PR interval, QRS duration, and QT interval were made blindly by 4 major manufacturers of digital electrocardiographs used in the United States from 600 XML files of ECG tracings stored in the US FDA ECG warehouse and released for the purpose of this study by the Cardiac Safety Research Consortium. Included were 3 groups based on expected QT interval and degree of repolarization abnormality, comprising 200 ECGs each from (1) placebo or baseline study period in normal subjects during thorough QT studies, (2) peak moxifloxacin effect in otherwise normal subjects during thorough QT studies, and (3) patients with genotyped variants of congenital long QT syndrome (LQTS). Differences of means between manufacturers were generally small in the normal and moxifloxacin subjects, but in the LQTS patients, differences of means ranged from 2.0 to 14.0 ms for QRS duration and from 0.8 to 18.1 ms for the QT interval. Mean absolute differences between algorithms were similar for QRS duration and QT intervals in the normal and in the moxifloxacin subjects (mean ≤6 ms) but were significantly larger in patients with LQTS. Small but statistically significant group differences in mean interval and duration measurements and means of individual absolute differences exist among automated algorithms of widely used, current generation digital electrocardiographs. Measurement differences, including QRS duration and the QT interval, are greatest for the most abnormal ECGs. © 2014.

  8. Assessment of the relationship between a narrow fragmented QRS complex and coronary slow flow.

    PubMed

    Cakmak, Huseyin Altug; Aslan, Serkan; Gul, Mehmet; Kalkan, Ali Kemal; Ozturk, Derya; Celik, Omer; Tasbulak, Omer; Satilmisoglu, Muhammet Hulusi

    2015-01-01

    The coronary slow flow (CSF) phenomenon is a delayed antegrade progression of contrast agent to the distal branch of a coronary artery in the absence of obstructive coronary artery disease (CAD). A narrow fragmented QRS (fQRS) has been reported as a significant predictor of sudden cardiac death in patients with idiopathic dilated cardiomyopathy. The present study aimed to investigate the relationship between a narrow fQRS on the admission electrocardiogram (ECG) and CSF on coronary angiography. This study included 165 consecutive patients (112 CSF, 53 controls) who underwent first-time diagnostic conventional coronary angiography for suspected CAD. Coronary flow was quantified by thrombolysis in myocardial infarction (TIMI) frame count (TFC). The patients were divided into two groups according to the presence or absence of a narrow fQRS complex on the admission ECG. Forty four patients were in the fQRS group (mean age, 52.97 ± 3.13 years). There was no difference between the two groups with respect to age, gender, body mass index, family history, hyperlipidemia, hypertension, or diabetes mellitus. The extent of CSF was significantly greater in the fQRS group compared to the non-fragmented group (p < 0.001). A significant correlation was also found between mean TFC values and fQRS (p < 0.001). On multivariate analysis, only CSF (p = 0.03) was a significant independent predictor for narrow fQRS, after adjustment for other parameters. The narrow fQRS is a simple, inexpensive, and readily available noninvasive ECG parameter that may be a new potential indicator of myocardial damage in patients with CSF.

  9. Virginia Star Quality Initiative: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Virginia's Star Quality Initiative prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators…

  10. Mississippi Quality Step System: QRS Profile. The Child Care Quality Rating System (QRS)Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Mississippi's Quality Step System prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Application…

  11. Palm Beach Quality Counts: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Palm Beach's Quality Counts prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for…

  12. Maine Quality for ME: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Maine's Quality for ME prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for Family…

  13. Missouri Quality Rating System: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Missouri's Quality Rating System prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for…

  14. Miami-Dade Quality Counts: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Miami-Dade's Quality Counts prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for…

  15. Indiana Paths to Quality: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Indiana's Paths to Quality prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for…

  16. Early Changes in QRS Frequency Following Cardiac Resynchronization Predict Hemodynamic Response in Left Bundle Branch Block Patients.

    PubMed

    Niebauer, Mark J; Rickard, John; Tchou, Patrick J; Varma, Niraj

    2016-05-01

    QRS characteristics are the cornerstone of patient selection in cardiac resynchronization therapy (CRT) and the presence of left bundle branch block (LBBB) and baseline QRS ≥150 milliseconds portends a good outcome. We previously showed that baseline QRS frequency analysis adds predictive value to LBBB alone and have hypothesized that a change in frequency characteristics following CRT may produce additional predictive value. We examined the QRS frequency characteristics of 182 LBBB patients before and soon after CRT. Patients were assigned to responder and nonresponder groups. Responders were defined by a decrease in left ventricular end-systolic volume (LVESV) ≥15% following CRT. We analyzed the QRS in ECG leads I, AVF, and V3 before and soon after CRT using the discrete Fourier transform algorithm. The percentage of total QRS power within discrete frequency intervals before and after CRT was calculated. The reduction in lead V3 power <10 Hz was the best indicator of response. Baseline QRS width was similar between the responders and nonresponders (162.2 ± 17.2 milliseconds vs. 158 ± 22.1 milliseconds, respectively; P = 0.180). Responders exhibited a greater reduction in QRS power <10 Hz (-17.0 ± 11.9% vs. -6.6 ± 12.5%; P < 0.001) and a significant AUC (0.743; P < 0.001). A ≥8% decline in QRS power <10 Hz produced the best predictive values (PPV = 84%, NPV = 59%). Importantly, when patients with baseline QRS <150 milliseconds were compared, the AUC improved (0.892, P < 0.001). Successful CRT produces a significant reduction in QRS power below 10 Hz, particularly when baseline QRS <150 milliseconds. These results indicate that QRS frequency changes after CRT provide additional predictive value to QRS alone. © 2016 Wiley Periodicals, Inc.

  17. QT Interval Prolongation and QRS Voltage Reduction in Patients with Liver Cirrhosis.

    PubMed

    Cichoż-Lach, Halina; Tomaszewski, Michał; Kowalik, Agnieszka; Lis, Emilia; Tomaszewski, Andrzej; Lach, Tomasz; Boczkowska, Sylwia; Celiński, Krzysztof

    2015-01-01

    Liver cirrhosis is associated with functional abnormalities of the cardiovascular system with co-existing electrocardiographic (ECG) abnormalities. The aim was to analyze ECG changes in patients with cirrhosis, to evaluate whether alcoholic etiology of cirrhosis and ascites has an impact on ECG changes. The study involved 81 patients with previously untreated alcoholic cirrhosis (64 patients with ascites, classes B and C according to the Child-Pugh classification; and 17 without ascites, categorized as class A); 41 patients with previously untreated cirrhosis due to chronic hepatitis C (HCV--30 patients with ascites, classes B and C; and 11 without ascites, class A); 42 with alcoholic steatohepatitis and 46 with alcoholic steatosis. The control group consisted of 32 healthy volunteers. Twelve-lead ECG recordings were performed and selected parameters were measured. Significantly longer QT and QTc intervals and lower QRS voltage were found in patients with alcoholic and HCV cirrhosis compared to the controls. Significantly lower QRS voltage was found in subjects with ascites than in those without ascites. Removal of ascites significantly increased QRS voltage. In cirrhosis, irrespective of etiology, ECG changes involved prolonged QT and QTc intervals and reduced QRS voltage. Prolonged QT and QTc intervals were not related to the severity of cirrhosis or to the presence of ascites. However, low QRS voltage was associated with the presence of ascites. Removal of ascites reverses low QRS voltage.

  18. The prognostic value of the frontal QRS-T angle is comparable to cardiovascular autonomic neuropathy regarding long-term mortality in people with diabetes. A population based study.

    PubMed

    May, O; Graversen, C B; Johansen, M Ø; Arildsen, H

    2018-06-09

    Cardiovascular autonomic neuropathy (CAN) is a well known prognostic marker in diabetes. A large angle between the QRS- and the T-wave vector (QRS-T angle) in the electrocardiogram (ECG) has recently been introduced as another marker of poor prognosis. To assess and compare the long-term predictive power of the frontal plane QRS-T angle with CAN in people with diabetes. In 1992-93 people with diabetes in the municipality of Horsens, Denmark, were identified by the prescription method andan age and gender stratified sample of 240 individuals with diabetes were randomly selected. The presence of CAN was defined using the heart rate response to Valsalva manoeuvre. The QRS-T angle was read using the method described by Gandhi. In July 2015 vital statistics were obtained fromthe Danish Civil Registration System. 178 individuals accepted to participate in the study, of which 153 (86%) completed the Valsalva manoeuvre and had sinus rhythm. Total observation time was 21.5 (0.18) years, in which 99 (65%) individuals died. An elevated QRS-T angle and the presence of cardiovascular autonomic neuropathy were both found to be significant predictors of death. In Cox regression analyses, adjusting for the effect of gender, age, duration of diabetes, BMI, total-cholesterol, diabetes type, haemoglobin A1c, smoking status, hypertension and previous MI, an independent prognostic value was found for the QRS-T angle as well as the Valsalva ratio. A large QRS-T angle and the presence of cardiovascular autonomic neuropathy are both strong and independent long-term predictors of all-cause mortality in people with diabetes. Copyright © 2018. Published by Elsevier B.V.

  19. Cadmium stress assessment based on the electrocardiogram characteristics of zebra fish (Danio rerio): QRS complex could play an important role.

    PubMed

    Xing, Na; Ji, Lizhen; Song, Jie; Ma, Jingchun; Li, Shangge; Ren, Zongming; Xu, Fei; Zhu, Jianping

    2017-10-01

    The electrocardiogram (ECG) of zebra fish (Danio rerio) expresses cardiac features that are similar to humans. Here we use sharp microelectrode measurements to obtain ECG characteristics in adult zebra fish and analyze the effects of cadmium chloride (CdCl 2 ) on the heart. We observe the overall changes of ECG parameters in different treatments (0.1 TU, 0.5 TU and 1.0 TU CdCl 2 ), including P wave, Q wave, R wave, S wave, T wave, PR interval (atrial contraction), QRS complex (ventricular depolarization), ST segment, and QT interval (ventricular repolarization). The trends of the ECG parameters showed some responses to the concentration and exposure time of CdCl 2 , but it was difficult to obtain more information about the useful indicators in water quality assessment depending on tendency analysis alone. A self-organizing map (SOM) showed that P values, R values, and T values were similar; R wave and T wave amplitude were similar; and most important, QRS value was similar to the CdCl 2 stress according to the classified data patterns including CdCl 2 stress (E) and ECG components based on the Ward linkage. It suggested that the duration of QRS complex was related to environmental stress E directly. The specification and evaluation of ECG parameters in Cd 2+ pollution suggested that there is a markedly significant correlation between QRS complex and CdCl 2 stress with the highest r (0.729) and the smallest p (0.002) among all ECG characteristics. In this case, it is concluded that QRS complex can be used as an indicator in the CdCl 2 stress assessment due to the lowest AIC data abased on the linear regression model between the CdCl 2 stress and ECG parameters. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Envelopment filter and K-means for the detection of QRS waveforms in electrocardiogram.

    PubMed

    Merino, Manuel; Gómez, Isabel María; Molina, Alberto J

    2015-06-01

    The electrocardiogram (ECG) is a well-established technique for determining the electrical activity of the heart and studying its diseases. One of the most common pieces of information that can be read from the ECG is the heart rate (HR) through the detection of its most prominent feature: the QRS complex. This paper describes an offline version and a real-time implementation of a new algorithm to determine QRS localization in the ECG signal based on its envelopment and K-means clustering algorithm. The envelopment is used to obtain a signal with only QRS complexes, deleting P, T, and U waves and baseline wander. Two moving average filters are applied to smooth data. The K-means algorithm classifies data into QRS and non-QRS. The technique is validated using 22 h of ECG data from five Physionet databases. These databases were arbitrarily selected to analyze different morphologies of QRS complexes: three stored data with cardiac pathologies, and two had data with normal heartbeats. The algorithm has a low computational load, with no decision thresholds. Furthermore, it does not require any additional parameter. Sensitivity, positive prediction and accuracy from results are over 99.7%. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  1. Fragmented QRS may predict new onset atrial fibrillation in patients with ST-segment elevation myocardial infarction.

    PubMed

    Yesin, Mahmut; Kalçık, Macit; Çağdaş, Metin; Karabağ, Yavuz; Rencüzoğulları, İbrahim; Gürsoy, Mustafa Ozan; Efe, Süleyman Çağan; Karakoyun, Süleyman

    Fragmented QRS (fQRS) has been shown to be a marker of local myocardial conduction abnormalities, cardiac fibrosis in previous studies. It was also reported to be a predictor of sudden cardiac death and increased morbidity and mortality in selected populations. However, there is no study investigating the role of fQRS in the development of atrial fibrillation in patients with ST segment elevation myocardial infarction (STEMI). In this study we aimed to investigate the relationship between the presence of fQRS after primary percutaneous coronary intervention (pPCI) and in-hospital development of new-onset atrial fibrilation (AF) in patients with STEMI. This study enrolled 171 patients undergoing pPCI for STEMI. Among these patients 24 patients developed AF and the remaining 147 patients were designated as the controls. All clinical, demographical and laboratory parameters were entered into a dataset and compared between AF group and the controls. The presence of fQRS was higher in the AF group than in the controls (P=0.001). Diabetes mellitus and fQRS was significantly more common in the AF group (P=0.003 and P=0.001 respectively) Logistic regression analysis demonstrated that the presence of fQRS was the independent determinant of AF (OR: 3.243, 95% CI 1.016-10.251, P=0.042). Increased atrial fibrillation was observed more frequently in STEMI patients with fQRS than in patients without fQRS. fQRS is an important determinant of AF in STEMI after pPCI. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Aiding the Detection of QRS Complex in ECG Signals by Detecting S Peaks Independently.

    PubMed

    Sabherwal, Pooja; Singh, Latika; Agrawal, Monika

    2018-03-30

    In this paper, a novel algorithm for the accurate detection of QRS complex by combining the independent detection of R and S peaks, using fusion algorithm is proposed. R peak detection has been extensively studied and is being used to detect the QRS complex. Whereas, S peaks, which is also part of QRS complex can be independently detected to aid the detection of QRS complex. In this paper, we suggest a method to first estimate S peak from raw ECG signal and then use them to aid the detection of QRS complex. The amplitude of S peak in ECG signal is relatively weak than corresponding R peak, which is traditionally used for the detection of QRS complex, therefore, an appropriate digital filter is designed to enhance the S peaks. These enhanced S peaks are then detected by adaptive thresholding. The algorithm is validated on all the signals of MIT-BIH arrhythmia database and noise stress database taken from physionet.org. The algorithm performs reasonably well even for the signals highly corrupted by noise. The algorithm performance is confirmed by sensitivity and positive predictivity of 99.99% and the detection accuracy of 99.98% for QRS complex detection. The number of false positives and false negatives resulted while analysis has been drastically reduced to 80 and 42 against the 98 and 84 the best results reported so far.

  3. Delaware Stars for Early Success. QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Delaware's Stars for Early Success prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators…

  4. Vermont STep Ahead Recognition System: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Vermont's STep Ahead Recognition System (STARS) prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for All Child Care Programs;…

  5. Kentucky STARS for KIDS NOW: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Kentucky's STARS for KIDS NOW prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for…

  6. New Hampshire Quality Rating System: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of New Hampshire's Quality Rating System prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4)…

  7. Ohio Step Up to Quality: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Ohio's Step Up to Quality prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for Family…

  8. 2D.03: IMPROVING DIAGNOSTIC STRATEGY IN PATIENTS WITH LONG-STANDING HYPERTENSION, CHEST PAIN AND NORMAL RESTING ECG: VALUE OF THE EXERCISE HIGH-FREQUENCY QRS VERSUS ST-SEGMENT ANALYSIS.

    PubMed

    Conti, A; Bianchi, S; Grifoni, C; Trausi, F; Angeli, E; Paolini, D; Catarzi, S; Perrotta, M E; Covelli, A; Renzi, N; Bertolini, P; Mazzucchelli, M

    2015-06-01

    The novel exercise computer-assisted high-frequency QRS-analysis (ex-HF/QRS) has demonstrated improved sensitivity and specificity over the conventional exercise-ST/ECG-segment-analysis (ex-ST/ECG) in the detection of myocardial ischemia. The aim of the present study was to test the implementation in diagnostic value of the ex-HF/QRS in patient with hypertension and chest pain (CP) versus the conventional ex-ST/ECG anlysis alone. Patients with long-standing hypertension, CP, normal ECG, troponin and echocardiography were enrolled. All patients underwent the ex-ST/ECG and ex-HF/QRS. A decrease >/=50% of the signal of ex-HF/QRS intensity recorded in two contiguous leads, at least, was considered as index of ischaemia, as ST-segment depression >/=2 mm or >/=1 mm and CP on ex-ST/ECG. Exclusion criteria were QRS duration >/=120 msec and inability to exercise. The end-point was the composite of coronary stenosis >50% or acute coronary syndrome, revascularization, cardiovascular death at 3-month follow-up. Six-hundred thirty-one patients were enrolled (age 61+/-15 y). The percentage of age-adjusted maximal predicted heart rate was 88+/-10 beat-per-minute and the maximal systolic blood pressure was 169+/-22 mmHg. Twenty-seven patients achieved the end-point. On multivariate analysis, both the ex-ST/ECG and ex-HF/QRS were predictors of the end-point. The ex-HF/QRS showed higher sensitivity (88% vs 50%; p = 0.003), lower specificity (77% vs 97%; p = 0.245) and comparable negative predictive value (99% vs 99%; p = NS) when compared to ex-ST/ECG. Receiver operator characteristics (ROC) analysis showed the incremental diagnostic value of the ex-HF/QRS (area: 0.64, 95% Confidence Intervals, CI 0.51-0.77) over conventional ex-ST/ECG (0.60, CI 0.52-0.66) and Chest Pain Score (0.53, CI 0.48-0.59); p = NS on pairwise C-statistic. In patients with long-standing hypertension and CP submitted to risk stratification with exercise tolerance test, the novel ex-HF/QRS

  9. A QRS Detection and R Point Recognition Method for Wearable Single-Lead ECG Devices.

    PubMed

    Chen, Chieh-Li; Chuang, Chun-Te

    2017-08-26

    In the new-generation wearable Electrocardiogram (ECG) system, signal processing with low power consumption is required to transmit data when detecting dangerous rhythms and to record signals when detecting abnormal rhythms. The QRS complex is a combination of three of the graphic deflection seen on a typical ECG. This study proposes a real-time QRS detection and R point recognition method with low computational complexity while maintaining a high accuracy. The enhancement of QRS segments and restraining of P and T waves are carried out by the proposed ECG signal transformation, which also leads to the elimination of baseline wandering. In this study, the QRS fiducial point is determined based on the detected crests and troughs of the transformed signal. Subsequently, the R point can be recognized based on four QRS waveform templates and preliminary heart rhythm classification can be also achieved at the same time. The performance of the proposed approach is demonstrated using the benchmark of the MIT-BIH Arrhythmia Database, where the QRS detected sensitivity (Se) and positive prediction (+P) are 99.82% and 99.81%, respectively. The result reveals the approach's advantage of low computational complexity, as well as the feasibility of the real-time application on a mobile phone and an embedded system.

  10. Tennessee Star-Quality Child Care Program: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Tennessee's Star-Quality Child Care Program prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4)…

  11. North Carolina Star Rated License System: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of North Carolina's Star Rated License System prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4)…

  12. Oregon Child Care Quality Indicators Program: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Oregon's Child Care Quality Indicators Program prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4)…

  13. Sudden cardiac death in adults with congenital heart disease: does QRS-complex fragmentation discriminate in structurally abnormal hearts?

    PubMed

    Vehmeijer, Jim T; Koyak, Zeliha; Bokma, Jouke P; Budts, Werner; Harris, Louise; Mulder, Barbara J M; de Groot, Joris R

    2018-06-01

    Sudden cardiac death (SCD) causes a large portion of all mortality in adult congenital heart disease (ACHD) patients. However, identification of high-risk patients remains challenging. Fragmented QRS-complexes (fQRS) are a marker for SCD in patients with acquired heart disease but data in ACHD patients are lacking. We therefore aim to evaluate the prognostic value of fQRS for SCD in ACHD patients. From a multicentre cohort of 25 790 ACHD patients, we included tachyarrhythmic SCD cases (n = 147), and controls (n = 266) matched by age, gender, congenital defect and (surgical) intervention. fQRS was defined as ≥1 discontinuous deflection in narrow QRS-complexes, and ≥2 in wide QRS-complexes (>120 ms), in two contiguous ECG leads. We calculated odds ratios (OR) using univariable and multivariable conditional logistic regression models correcting for impaired systemic ventricular function, heart failure and QRS duration >120 ms. ECGs of 147 SCD cases (65% male, median age of death 34 years) and of 266 controls were assessed. fQRS was present in 51% of cases and 34% of controls (OR 2.0, P = 0.003). In multivariable analysis, fQRS was independently associated with SCD (OR 1.9, P = 0.01). The most common diagnose of SCD cases was tetralogy of Fallot (ToF, 34 cases). In ToF, fQRS was present in 71% of cases vs. 43% of controls (OR for SCD 2.8, P = 0.03). fQRS was independently associated with SCD in ACHD patients in a cohort of SCD patients and matched controls. fQRS may therefore contribute to the decision when evaluating ACHD patients for primary prevention of SCD.

  14. Real-time, high frequency QRS electrocardiograph

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd T. (Inventor); DePalma, Jude L. (Inventor); Moradi, Saeed (Inventor)

    2006-01-01

    Real time cardiac electrical data are received from a patient, manipulated to determine various useful aspects of the ECG signal, and displayed in real time in a useful form on a computer screen or monitor. The monitor displays the high frequency data from the QRS complex in units of microvolts, juxtaposed with a display of conventional ECG data in units of millivolts or microvolts. The high frequency data are analyzed for their root mean square (RMS) voltage values and the discrete RMS values and related parameters are displayed in real time. The high frequency data from the QRS complex are analyzed with imbedded algorithms to determine the presence or absence of reduced amplitude zones, referred to herein as RAZs. RAZs are displayed as go, no-go signals on the computer monitor. The RMS and related values of the high frequency components are displayed as time varying signals, and the presence or absence of RAZs may be similarly displayed over time.

  15. Identification of QRS complex in non-stationary electrocardiogram of sick infants.

    PubMed

    Kota, S; Swisher, C B; Al-Shargabi, T; Andescavage, N; du Plessis, A; Govindan, R B

    2017-08-01

    Due to the high-frequency of routine interventions in an intensive care setting, electrocardiogram (ECG) recordings from sick infants are highly non-stationary, with recurrent changes in the baseline, alterations in the morphology of the waveform, and attenuations of the signal strength. Current methods lack reliability in identifying QRS complexes (a marker of individual cardiac cycles) in the non-stationary ECG. In the current study we address this problem by proposing a novel approach to QRS complex identification. Our approach employs lowpass filtering, half-wave rectification, and the use of instantaneous Hilbert phase to identify QRS complexes in the ECG. We demonstrate the application of this method using ECG recordings from eight preterm infants undergoing intensive care, as well as from 18 normal adult volunteers available via a public database. We compared our approach to the commonly used approaches including Pan and Tompkins (PT), gqrs, wavedet, and wqrs for identifying QRS complexes and then compared each with manually identified QRS complexes. For preterm infants, a comparison between the QRS complexes identified by our approach and those identified through manual annotations yielded sensitivity and positive predictive values of 99% and 99.91%, respectively. The comparison metrics for each method are as follows: PT (sensitivity: 84.49%, positive predictive value: 99.88%), gqrs (85.25%, 99.49%), wavedet (95.24%, 99.86%), and wqrs (96.99%, 96.55%). Thus, the sensitivity values of the four methods previously described, are lower than the sensitivity of the method we propose; however, the positive predictive values of these other approaches is comparable to those of our method, with the exception of the wqrs approach, which yielded a slightly lower value. For adult ECG, our approach yielded a sensitivity of 99.78%, whereas PT yielded 99.79%. The positive predictive value was 99.42% for both our approach as well as for PT. We propose a novel method for

  16. Iowa Child Care Quality Rating System: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Iowa's Child Care Quality Rating System prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile is divided into the following categories: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for Family Child Care Programs;…

  17. QRS complex detection based on continuous density hidden Markov models using univariate observations

    NASA Astrophysics Data System (ADS)

    Sotelo, S.; Arenas, W.; Altuve, M.

    2018-04-01

    In the electrocardiogram (ECG), the detection of QRS complexes is a fundamental step in the ECG signal processing chain since it allows the determination of other characteristics waves of the ECG and provides information about heart rate variability. In this work, an automatic QRS complex detector based on continuous density hidden Markov models (HMM) is proposed. HMM were trained using univariate observation sequences taken either from QRS complexes or their derivatives. The detection approach is based on the log-likelihood comparison of the observation sequence with a fixed threshold. A sliding window was used to obtain the observation sequence to be evaluated by the model. The threshold was optimized by receiver operating characteristic curves. Sensitivity (Sen), specificity (Spc) and F1 score were used to evaluate the detection performance. The approach was validated using ECG recordings from the MIT-BIH Arrhythmia database. A 6-fold cross-validation shows that the best detection performance was achieved with 2 states HMM trained with QRS complexes sequences (Sen = 0.668, Spc = 0.360 and F1 = 0.309). We concluded that these univariate sequences provide enough information to characterize the QRS complex dynamics from HMM. Future works are directed to the use of multivariate observations to increase the detection performance.

  18. Louisiana Quality Start Child Care Rating System: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Louisiana's Quality Start Child Care Rating System prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs;…

  19. Los Angeles County Steps to Excellence Project: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Los Angeles County's Steps to Excellence Project prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs;…

  20. Fragmented QRS and mortality in patients undergoing percutaneous intervention for ST-elevation myocardial infarction: Systematic review and meta-analysis.

    PubMed

    Kanjanahattakij, Napatt; Rattanawong, Pattara; Riangwiwat, Tanawan; Prasitlumkum, Narut; Limpruttidham, Nath; Chongsathidkiet, Pakawat; Vutthikraivit, Wasawat; Crossey, Erin

    2018-06-22

    Fragmented QRS reflects disturbances in the myocardium predisposing the heart to ventricular tachyarrhythmias. Recent studies suggest that fragmented QRS (fQRS) is associated with mortality in ST-elevation myocardial infarction (STEMI) patients who underwent percutaneous coronary intervention (PCI). However, a systematic review and meta-analysis of the literature has not been done. We assessed the association between fQRS and overall mortality in STEMI patients who subsequently underwent PCI by a systematic review and meta-analysis. We comprehensively searched the databases of MEDLINE and EMBASE from inception to September 2017. Studies included in our analysis were published cohort (prospective or retrospective) and case-control studies that compared overall mortality among STEMI patient with and without fQRS who underwent PCI. Data from each study were combined using the random-effects, generic inverse variance method of DerSimonian, and Laird to calculate risk ratios and 95% confidence intervals. Six studies from 2014 to 2017 were included in this meta-analysis involving 2,516 subjects with STEMI who underwent PCI (888 fQRS and 1,628 non-fQRS). Fragmented QRS was associated with overall mortality in STEMI patients who underwent PCI (pooled risk ratio = 3.87; 95% CI 1.96-7.66, I 2  = 43%). Fragmented QRS was associated with increased overall mortality up to threefold. Our study suggests that fQRS could be an important tool for risk assessment in STEMI patients who underwent PCI. © 2018 Wiley Periodicals, Inc.

  1. QRS slopes for assessment of myocardial damage in chronic chagasic patients

    NASA Astrophysics Data System (ADS)

    Pueyo, E.; Laciar, E.; Anzuola, E.; Laguna, P.; Jané, R.

    2007-11-01

    In this study the slopes of the QRS complex are evaluated for determination of the degree of myocardial damage in chronic chagasic patients. Previous studies have demonstrated the ability of the slope indices to reflect alterations in the conduction velocity of the cardiac impulse. Results obtained in the present study show that chronic chagasic patients have significantly flatter QRS slopes as compared to healthy subjects. Not only that but the extent of slope lessening turns out to be proportional to the degree of myocardial damage caused by the disease. Additionally, when incorporating the slope indices into a classification analysis together with other indices indicative of the presence of ventricular late potentials obtained from high resolution electrocardiography, results show that the percentages of correct classification increase up to 62.5%, which means eight points above the percentages obtained prior to incorporation of the slope indices. It can be concluded that QRS slopes have great potential for assessing the degree of severity associated with Chagas' disease.

  2. New Mexico Look for the STARS--AIM HIGH: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of New Mexico's Look for the STARS--AIM HIGH prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4)…

  3. The T/QRS ratio values in pregnancies complicated by threatened preterm labour treated with intravenous infusions of fenoterol.

    PubMed

    Fuchs, Tomasz; Pomorski, Michał; Grobelak, Krzysztof; Zimmer, Mariusz

    2015-07-01

    To evaluate values of foetal T/QRS ratios in pregnancies complicated by threatened preterm labour treated with intravenous infusions of fenoterol using non-invasive methods with transabdominal electrodes. The study group consisted of 451 Caucasian women (63 preterm pregnancies and 327 healthy controls) whose pregnancies ranged from 28 to 37 gestational weeks. Foetal electrocardiograms were recorded and T/QRS ratios were calculated by KOMPOREL software (ITAM, Zabrze, Poland). The first recording was performed 30 min after the start of fenoterol infusion and the second 2 days after finishing tocolysis. T/QRS ratio variables were calculated. One-way analysis of variance was carried out. Significantly higher mean values of the T/QRS ratio were observed in pregnancies during tocolytic treatment in comparison to controls and pregnancies after tocolysis (P=0.0158 and P=0.0071, respectively). The T/QRS ratio values fall again shortly after finishing intravenous tocolysis. The T/QRS ratio is one of the methods used for non-invasive foetal distress assessment that can be used in antepartum foetal monitoring in complicated pregnancies. Raised values of the T/QRS ratio in the foetus during tocolysis with fenoterol and next its fall to values observed in physiological pregnancies may indicate transient worsening of fetal well-being, however, additional research is required.

  4. Comparison between fragmented QRS and Q waves in myocardial scar detection using myocardial perfusion single photon emission computed tomography.

    PubMed

    Dabbagh Kakhki, Vahid Reza; Ayati, Narjess; Zakavi, Seyed Rasoul; Sadeghi, Ramin; Tayyebi, Mohammad; Shariati, Farzaneh

    2015-01-01

    Accurate diagnosis of myocardial infarction (MI) is of paramount importance in patient management, which necessitates the development of efficient and accurate diagnostic methods. Q wave is not present in all patients with MI, and its prevalence is declining. Recently, fragmented QRS (fQRS) complex has been introduced as a marker of prior MI. To investigate diagnostic value of fQRS compared to Q wave. We included 500 consecutive patients with known or suspected coronary artery disease who underwent two days of gated myocardial perfusion imaging using dipyridamole pharmacologic stress. Electrocardiogram (ECG) was evaluated to detect fQRS as well as Q-wave. Finally, subjects were compared in terms of ventricular perfusion and function indices. A total of 207 men and 269 women with mean age of 57.06 ± 12 years were studied. ECG analysis showed that 14.3% of the patients had both fQRS and Q waves, 30.7% had fQRS, and 3.8% had Q waves. Fixed myocardial perfusion defect was noted in 22.3% of patients according to MPIs. Sensitivity, specificity, and positive and negative predictive values for myocardial scar detection were 78%, 65%, 39%, and 91%, respectively, for fQRS and 61%, 94%, 76%, and 89%, respectively, for Q wave. Although fQRS had lower specificity compared to Q wave in the detection of myocardial scar, due to higher sensitivity and negative predictive value can be an invaluable diagnostic index. There is also an incremental value for fQRS in association with Q-wave in myocardial scar assessment.

  5. Fetal QRS detection and heart rate estimation: a wavelet-based approach.

    PubMed

    Almeida, Rute; Gonçalves, Hernâni; Bernardes, João; Rocha, Ana Paula

    2014-08-01

    Fetal heart rate monitoring is used for pregnancy surveillance in obstetric units all over the world but in spite of recent advances in analysis methods, there are still inherent technical limitations that bound its contribution to the improvement of perinatal indicators. In this work, a previously published wavelet transform based QRS detector, validated over standard electrocardiogram (ECG) databases, is adapted to fetal QRS detection over abdominal fetal ECG. Maternal ECG waves were first located using the original detector and afterwards a version with parameters adapted for fetal physiology was applied to detect fetal QRS, excluding signal singularities associated with maternal heartbeats. Single lead (SL) based marks were combined in a single annotator with post processing rules (SLR) from which fetal RR and fetal heart rate (FHR) measures can be computed. Data from PhysioNet with reference fetal QRS locations was considered for validation, with SLR outperforming SL including ICA based detections. The error in estimated FHR using SLR was lower than 20 bpm for more than 80% of the processed files. The median error in 1 min based FHR estimation was 0.13 bpm, with a correlation between reference and estimated FHR of 0.48, which increased to 0.73 when considering only records for which estimated FHR > 110 bpm. This allows us to conclude that the proposed methodology is able to provide a clinically useful estimation of the FHR.

  6. Data fusion for QRS complex detection in multi-lead electrocardiogram recordings

    NASA Astrophysics Data System (ADS)

    Ledezma, Carlos A.; Perpiñan, Gilberto; Severeyn, Erika; Altuve, Miguel

    2015-12-01

    Heart diseases are the main cause of death worldwide. The first step in the diagnose of these diseases is the analysis of the electrocardiographic (ECG) signal. In turn, the ECG analysis begins with the detection of the QRS complex, which is the one with the most energy in the cardiac cycle. Numerous methods have been proposed in the bibliography for QRS complex detection, but few authors have analyzed the possibility of taking advantage of the information redundancy present in multiple ECG leads (simultaneously acquired) to produce accurate QRS detection. In our previous work we presented such an approach, proposing various data fusion techniques to combine the detections made by an algorithm on multiple ECG leads. In this paper we present further studies that show the advantages of this multi-lead detection approach, analyzing how many leads are necessary in order to observe an improvement in the detection performance. A well known QRS detection algorithm was used to test the fusion techniques on the St. Petersburg Institute of Cardiological Technics database. Results show improvement in the detection performance with as little as three leads, but the reliability of these results becomes interesting only after using seven or more leads. Results were evaluated using the detection error rate (DER). The multi-lead detection approach allows an improvement from DER = 3:04% to DER = 1:88%. Further works are to be made in order to improve the detection performance by implementing further fusion steps.

  7. The prognostic impact of dynamic ventricular dyssynchrony in patients with idiopathic dilated cardiomyopathy and narrow QRS.

    PubMed

    D'Andrea, Antonello; Mele, Donato; Nistri, Stefano; Riegler, Lucia; Galderisi, Maurizio; Agricola, Eustachio; Losi, Maria Angela; Ballo, Piercarlo; Mondillo, Sergio; Badano, Luigi P

    2013-02-01

    Asynchronous myocardial contraction adversely influences left ventricular (LV) function and is therefore associated with a poor prognosis in heart failure. Exercise-induced change in ventricular dyssynchrony may be an important determinant of dynamic changes in cardiac output and mitral regurgitation. A prospective, longitudinal study was designed with pre-defined dyssynchrony index and outcome variables to test the hypothesis that dynamic dyssynchrony is associated with worse long-term event-free survival in patients with dilated cardiomyopathy (DCM) and 'narrow' QRS complex. One-hundred eighty patients (62 ± 8 years; 110 males) with NYHA class II-III, idiopathic DCM, ejection fraction ≤35%, and QRS duration <120 ms were selected. All the patients underwent standard Doppler echo, colour tissue velocity imaging (DTI), and supine bicycle exercise stress echocardiography. Cardiac synchronicity was defined, at rest and at peak exercise, as DTI velocity opposing-wall delay (significant if ≥65 ms). Outcome was defined as freedom from death, heart transplantation, or LV-assist device implantation, over a median follow-up of 48 months, and a Cox proportional hazards model was used for survival analysis. At baseline examination, DCM patients showed a reduced LV ejection fraction (31 + 4%). A significant electromechanical delay in 58 patients (32%). At the peak of physical exercise, a significant electromechanical delay was detected in 103 patients (57%). There were 41 events during the follow-up (23%): 28 cardiac deaths, 8 heart transplantations, and 5 LV-assist device implantations over 4 years. When adjusted for confounding baseline variables, LV end-diastolic volume, restrictive mitral flow pattern, severity of mitral regurgitation, and the presence of exercise-induced intraventricular dyssynchrony were the only independent determinants of an adverse outcome. In patients with idiopathic DCM and narrow QRS, the increase in echocardiographic dyssynchrony during

  8. A lightweight QRS detector for single lead ECG signals using a max-min difference algorithm.

    PubMed

    Pandit, Diptangshu; Zhang, Li; Liu, Chengyu; Chattopadhyay, Samiran; Aslam, Nauman; Lim, Chee Peng

    2017-06-01

    Detection of the R-peak pertaining to the QRS complex of an ECG signal plays an important role for the diagnosis of a patient's heart condition. To accurately identify the QRS locations from the acquired raw ECG signals, we need to handle a number of challenges, which include noise, baseline wander, varying peak amplitudes, and signal abnormality. This research aims to address these challenges by developing an efficient lightweight algorithm for QRS (i.e., R-peak) detection from raw ECG signals. A lightweight real-time sliding window-based Max-Min Difference (MMD) algorithm for QRS detection from Lead II ECG signals is proposed. Targeting to achieve the best trade-off between computational efficiency and detection accuracy, the proposed algorithm consists of five key steps for QRS detection, namely, baseline correction, MMD curve generation, dynamic threshold computation, R-peak detection, and error correction. Five annotated databases from Physionet are used for evaluating the proposed algorithm in R-peak detection. Integrated with a feature extraction technique and a neural network classifier, the proposed ORS detection algorithm has also been extended to undertake normal and abnormal heartbeat detection from ECG signals. The proposed algorithm exhibits a high degree of robustness in QRS detection and achieves an average sensitivity of 99.62% and an average positive predictivity of 99.67%. Its performance compares favorably with those from the existing state-of-the-art models reported in the literature. In regards to normal and abnormal heartbeat detection, the proposed QRS detection algorithm in combination with the feature extraction technique and neural network classifier achieves an overall accuracy rate of 93.44% based on an empirical evaluation using the MIT-BIH Arrhythmia data set with 10-fold cross validation. In comparison with other related studies, the proposed algorithm offers a lightweight adaptive alternative for R-peak detection with good

  9. Revisiting QRS detection methodologies for portable, wearable, battery-operated, and wireless ECG systems.

    PubMed

    Elgendi, Mohamed; Eskofier, Björn; Dokos, Socrates; Abbott, Derek

    2014-01-01

    Cardiovascular diseases are the number one cause of death worldwide. Currently, portable battery-operated systems such as mobile phones with wireless ECG sensors have the potential to be used in continuous cardiac function assessment that can be easily integrated into daily life. These portable point-of-care diagnostic systems can therefore help unveil and treat cardiovascular diseases. The basis for ECG analysis is a robust detection of the prominent QRS complex, as well as other ECG signal characteristics. However, it is not clear from the literature which ECG analysis algorithms are suited for an implementation on a mobile device. We investigate current QRS detection algorithms based on three assessment criteria: 1) robustness to noise, 2) parameter choice, and 3) numerical efficiency, in order to target a universal fast-robust detector. Furthermore, existing QRS detection algorithms may provide an acceptable solution only on small segments of ECG signals, within a certain amplitude range, or amid particular types of arrhythmia and/or noise. These issues are discussed in the context of a comparison with the most conventional algorithms, followed by future recommendations for developing reliable QRS detection schemes suitable for implementation on battery-operated mobile devices.

  10. Revisiting QRS Detection Methodologies for Portable, Wearable, Battery-Operated, and Wireless ECG Systems

    PubMed Central

    Elgendi, Mohamed; Eskofier, Björn; Dokos, Socrates; Abbott, Derek

    2014-01-01

    Cardiovascular diseases are the number one cause of death worldwide. Currently, portable battery-operated systems such as mobile phones with wireless ECG sensors have the potential to be used in continuous cardiac function assessment that can be easily integrated into daily life. These portable point-of-care diagnostic systems can therefore help unveil and treat cardiovascular diseases. The basis for ECG analysis is a robust detection of the prominent QRS complex, as well as other ECG signal characteristics. However, it is not clear from the literature which ECG analysis algorithms are suited for an implementation on a mobile device. We investigate current QRS detection algorithms based on three assessment criteria: 1) robustness to noise, 2) parameter choice, and 3) numerical efficiency, in order to target a universal fast-robust detector. Furthermore, existing QRS detection algorithms may provide an acceptable solution only on small segments of ECG signals, within a certain amplitude range, or amid particular types of arrhythmia and/or noise. These issues are discussed in the context of a comparison with the most conventional algorithms, followed by future recommendations for developing reliable QRS detection schemes suitable for implementation on battery-operated mobile devices. PMID:24409290

  11. Robust QRS detection for HRV estimation from compressively sensed ECG measurements for remote health-monitoring systems.

    PubMed

    Pant, Jeevan K; Krishnan, Sridhar

    2018-03-15

    To present a new compressive sensing (CS)-based method for the acquisition of ECG signals and for robust estimation of heart-rate variability (HRV) parameters from compressively sensed measurements with high compression ratio. CS is used in the biosensor to compress the ECG signal. Estimation of the locations of QRS segments is carried out by applying two algorithms on the compressed measurements. The first algorithm reconstructs the ECG signal by enforcing a block-sparse structure on the first-order difference of the signal, so the transient QRS segments are significantly emphasized on the first-order difference of the signal. Multiple block-divisions of the signals are carried out with various block lengths, and multiple reconstructed signals are combined to enhance the robustness of the localization of the QRS segments. The second algorithm removes errors in the locations of QRS segments by applying low-pass filtering and morphological operations. The proposed CS-based method is found to be effective for the reconstruction of ECG signals by enforcing transient QRS structures on the first-order difference of the signal. It is demonstrated to be robust not only to high compression ratio but also to various artefacts present in ECG signals acquired by using on-body wireless sensors. HRV parameters computed by using the QRS locations estimated from the signals reconstructed with a compression ratio as high as 90% are comparable with that computed by using QRS locations estimated by using the Pan-Tompkins algorithm. The proposed method is useful for the realization of long-term HRV monitoring systems by using CS-based low-power wireless on-body biosensors.

  12. Investigation of mindin levels in hypertensive patients with left ventricular hypertrophy and QRS fragmentation on electrocardiography.

    PubMed

    Doğan, Tolga; Yetim, Mucahit; Çelik, Oğuzhan; Kalçık, Macit; Özcan, Oğuzhan; Doğan, İbrahim; Erenler, Ali Kemal; Bekar, Lütfü; Karavelioğlu, Yusuf

    2017-12-21

    Mindin was associated with diabetic nephropathy, podocyte injury, colitis, allergic asthma, liver ischaemia and reperpusion injury and ischaemic brain injury. On the other hand, it was reported as a protective factor against obesity, cardiac hypertrophy, fibrosis and remodelling. Fragmented QRS complexes (fQRS) are markers of altered ventricular depolarisation owing to a prior myocardial scar and fibrosis. In this study, we aimed to investigate mindin levels in hypertensive patients with left ventricular hypertrophy and fQRS on electrocardiography. This observational case-control study enrolled 70 (36 female) hypertensive patients with fQRS and 38 (23 female) hypertensive control patients. All patients were evaluated by transthoracic echocardiography. Mindin levels were measured by the enzyme-linked immunosorbent assay (ELISA). Clinical, echocardiographic and laboratory data were compared between patient and control groups. There was no significant difference between patient and control groups in terms of clinical, echocardiographic and routine laboratory parameters. The mindin levels were significantly higher in the patient group than controls (11.3 (7.21-19.31) vs 4.15 (2.86-6.34); p < .001). Multiple logistic regression analyses defined increased mindin levels as an independent predictor for the presence of fQRS (Odds ratio: 1.733; p = .034). Mindin levels >6.74 predicted the presence of fQRS with a sensitifity of 84.3% and specificity of 79.9% on receiver operating characteristic (ROC) curve analysis (The area under the curve:0.889; Confidence Interval: 0.827-0.951; p < .001). Mindin expressin is upregulated in hypertensive patients with fQRS complexes. In contrary to previous studies, increased mindin levels may be associated with myocardial fibrosis.

  13. Robust QRS peak detection by multimodal information fusion of ECG and blood pressure signals.

    PubMed

    Ding, Quan; Bai, Yong; Erol, Yusuf Bugra; Salas-Boni, Rebeca; Zhang, Xiaorong; Hu, Xiao

    2016-11-01

    QRS peak detection is a challenging problem when ECG signal is corrupted. However, additional physiological signals may also provide information about the QRS position. In this study, we focus on a unique benchmark provided by PhysioNet/Computing in Cardiology Challenge 2014 and Physiological Measurement focus issue: robust detection of heart beats in multimodal data, which aimed to explore robust methods for QRS detection in multimodal physiological signals. A dataset of 200 training and 210 testing records are used, where the testing records are hidden for evaluating the performance only. An information fusion framework for robust QRS detection is proposed by leveraging existing ECG and ABP analysis tools and combining heart beats derived from different sources. Results show that our approach achieves an overall accuracy of 90.94% and 88.66% on the training and testing datasets, respectively. Furthermore, we observe expected performance at each step of the proposed approach, as an evidence of the effectiveness of our approach. Discussion on the limitations of our approach is also provided.

  14. Value of the Qrs-T Angle in Predicting the Induction of Ventricular Tachyarrhythmias in Patients with Chagas Disease.

    PubMed

    Zampa, Hugo Bizetto; Moreira, Dalmo Ar; Ferreira Filho, Carlos Alberto Brandão; Souza, Charles Rios; Menezes, Camila Caldas; Hirata, Henrique Seichii; Armaganijan, Luciana Vidal

    2014-10-28

    Background: The QRS-T angle correlates with prognosis in patients with heart failure and coronary artery disease, reflected by an increase in mortality proportional to an increase in the difference between the axes of the QRS complex and T wave in the frontal plane. The value of this correlation in patients with Chagas heart disease is currently unknown. Objective: Determine the correlation of the QRS-T angle and the risk of induction of ventricular tachycardia / ventricular fibrillation (VT / VF) during electrophysiological study (EPS) in patients with Chagas disease. Methods: Case-control study at a tertiary center. Patients without induction of VT / VF on EPS were used as controls. The QRS-T angle was categorized as normal (0-105º), borderline (105-135º) or abnormal (135-180º). Differences between groups for continuous variables were analyzed with the t test or Mann-Whitney test, and for categorical variables with Fisher's exact test. P values < 0.05 were considered significant. Results: Of 116 patients undergoing EPS, 37.9% were excluded due to incomplete information / inactive records or due to the impossibility to correctly calculate the QRS-T angle (presence of left bundle branch block and atrial fibrillation). Of 72 patients included in the study, 31 induced VT / VF on EPS. Of these, the QRS-T angle was normal in 41.9%, borderline in 12.9% and abnormal in 45.2%. Among patients without induction of VT / VF on EPS, the QRS-T angle was normal in 63.4%, borderline in 14.6% and abnormal in 17.1% (p = 0.04). When compared with patients with normal QRS-T angle, those with abnormal angle had a fourfold higher risk of inducing ventricular tachycardia / ventricular fibrillation on EPS [odds ratio (OR) 4; confidence interval (CI) 1.298-12.325; p = 0.028]. After adjustment for other variables such as age, ejection fraction (EF) and QRS size, there was a trend for the abnormal QRS-T angle to identify patients with increased risk of inducing VT / VF during EPS (OR 3

  15. QRS detection based ECG quality assessment.

    PubMed

    Hayn, Dieter; Jammerbund, Bernhard; Schreier, Günter

    2012-09-01

    Although immediate feedback concerning ECG signal quality during recording is useful, up to now not much literature describing quality measures is available. We have implemented and evaluated four ECG quality measures. Empty lead criterion (A), spike detection criterion (B) and lead crossing point criterion (C) were calculated from basic signal properties. Measure D quantified the robustness of QRS detection when applied to the signal. An advanced Matlab-based algorithm combining all four measures and a simplified algorithm for Android platforms, excluding measure D, were developed. Both algorithms were evaluated by taking part in the Computing in Cardiology Challenge 2011. Each measure's accuracy and computing time was evaluated separately. During the challenge, the advanced algorithm correctly classified 93.3% of the ECGs in the training-set and 91.6 % in the test-set. Scores for the simplified algorithm were 0.834 in event 2 and 0.873 in event 3. Computing time for measure D was almost five times higher than for other measures. Required accuracy levels depend on the application and are related to computing time. While our simplified algorithm may be accurate for real-time feedback during ECG self-recordings, QRS detection based measures can further increase the performance if sufficient computing power is available.

  16. When Deriving the Spatial QRS-T Angle from the 12-lead ECG, which Transform is More Frank: Regression or Inverse Dower?

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd T.; Cortez, Daniel

    2010-01-01

    Our primary objective was to ascertain which commonly used 12-to-Frank-lead transformation yields spatial QRS-T angle values closest to those obtained from simultaneously collected true Frank-lead recordings. Simultaneous 12-lead and Frank XYZ-lead recordings were analyzed for 100 post-myocardial infarction patients and 50 controls. Relative agreement, with true Frank-lead results, of 12-to-Frank-lead transformed results for the spatial QRS-T angle using Kors regression versus inverse Dower was assessed via ANOVA, Lin s concordance and Bland-Altman plots. Spatial QRS-T angles from the true Frank leads were not significantly different than those derived from the Kors regression-related transformation but were significantly smaller than those derived from the inverse Dower-related transformation (P less than 0.001). Independent of method, spatial mean QRS-T angles were also always significantly larger than spatial maximum (peaks) QRS-T angles. Spatial QRS-T angles are best approximated by regression-related transforms. Spatial mean and spatial peaks QRS-T angles should also not be used interchangeably.

  17. A narrow QRS tachycardia and cannon A waves: What is the mechanism?

    PubMed

    Ali, Hussam; Epicoco, Gianluca; De Ambroggi, Guido; Lupo, Pierpaolo; Foresti, Sara; Cappato, Riccardo

    2017-07-01

    Regular narrow QRS tachycardia, particularly if well-tolerated, is usually considered a "benign" arrhythmia of a supraventricular origin. This case concerns an 82-year-old male with ischemic heart disease who presented with recurrent episodes of a narrow QRS tachycardia that was initially diagnosed and treated as atrial tachyarrhythmia. However, careful physical examination and ECG analysis established the correct diagnosis, and the patient was managed appropriately. Remarkably, the observation of irregular cannon A waves, and Lewis lead recording, confirmed atrioventricular dissociation during tachycardia and indicated its underlying mechanism. © 2016 Wiley Periodicals, Inc.

  18. Compendium of Quality Rating Systems and Evaluations: The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Tout, Kathryn; Starr, Rebecca; Soli, Margaret; Moodie, Shannon; Kirby, Gretchen; Boller, Kimberly

    2010-01-01

    Quality Rating Systems (QRS) are currently operating, under development, or being piloted in over 25 states or local areas. As the QRS model becomes integrated into the landscape of child care and education service delivery, policy, and the decisions parents make about child care across the United States, there is an increasing need for…

  19. Association of intraventricular mechanical dyssynchrony with response to cardiac resynchronization therapy in heart failure patients with a narrow QRS complex

    PubMed Central

    van Bommel, Rutger J.; Tanaka, Hidekazu; Delgado, Victoria; Bertini, Matteo; Borleffs, Carel Jan Willem; Ajmone Marsan, Nina; Holzmeister, Johannes; Ruschitzka, Frank; Schalij, Martin J.; Bax, Jeroen J.; Gorcsan, John

    2010-01-01

    Aims Current criteria for cardiac resynchronization therapy (CRT) are restricted to patients with a wide QRS complex (>120 ms). Overall, only 30% of heart failure patients demonstrate a wide QRS complex, leaving the majority of heart failure patients without this treatment option. However, patients with a narrow QRS complex exhibit left ventricular (LV) mechanical dyssynchrony, as assessed with echocardiography. To further elucidate the possible beneficial effect of CRT in heart failure patients with a narrow QRS complex, this two-centre, non-randomized observational study focused on different echocardiographic parameters of LV mechanical dyssynchrony reflecting atrioventricular, interventricular and intraventricular dyssynchrony, and the response to CRT in these patients. Methods and results A total of 123 consecutive heart failure patients with a narrow QRS complex (<120 ms) undergoing CRT was included at two centres. Several widely accepted measures of mechanical dyssynchrony were evaluated: LV filling ratio (LVFT/RR), LV pre-ejection time (LPEI), interventricular mechanical dyssynchrony (IVMD), opposing wall delay (OWD), and anteroseptal posterior wall delay with speckle tracking (ASPWD). Response to CRT was defined as a reduction ≥15% in left ventricular end-systolic volume at 6 months follow-up. Measures of dyssynchrony can frequently be observed in patients with a narrow QRS complex. Nonetheless, for LVFT/RR, LPEI, and IVMD, presence of predefined significant dyssynchrony is <20%. Significant intraventricular dyssynchrony is more widely observed in these patients. With receiver operator characteristic curve analyses, both OWD and ASPWD demonstrated usefulness in predicting response to CRT in narrow QRS patients with a cut-off value of 75 and 107 ms, respectively. Conclusion Mechanical dyssynchrony can be widely observed in heart failure patients with a narrow QRS complex. In particular, intraventricular measures of mechanical dyssynchrony may be useful in

  20. Case report: an unstable wide QRS complexes tachycardia after ablation of a poster-septal accessory pathway: What is the mechanism?

    PubMed

    Wang, Huan; Che, Xiaoru

    2018-03-01

    Differentiation of wide QRS complex tachycardia required repeated electrophysiological stimuli and mapping. However, instability of tachycardia would increase the difficulty in differential diagnosis. In this paper, we reported a wide QRS tachycardia following ablation of an atrioventricular reentrant tachycardia participated by a poster-septal accessory pathway. Limited differentiation strategy was performed because the wide QRS tachycardia was self-limited and with unstable hemodynamics. We analyzed the mechanism of the wide QRS tachycardia by only 4 beats ventricular overpacing. On the basis of the last ventricular pacing, an atypical atrioventricular nodal reentrant tachycardia was confirmed. After slow-pathway modification, the wide QRS tachycardia was eliminated. It was an atypical atrial-ventricular node reentrant tachycardia with right bundle branch block. Reasonable analysis based on electrophysiological electrophysiologic knowledge was the basis of successful diagnosis and treatment.

  1. District of Columbia Going for the Gold Tiered Rate Reimbursement System. QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of District of Columbia's Going for the Gold Tiered Rate Reimbursement Systemp repared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for…

  2. Detection of ischemical dyssynchrony in patients with normal duration of QRS at rest and during exercise echocardiography (Dyssynchrony in coronary artery disease patients during exercise).

    PubMed

    Zagatina, A; Guseva, O; Bartosh-Zelenaya, S Y; Zhuravskaya, N

    2014-04-01

    Ischemic segments cannot develop a sufficient amount of strength during systole, so theoretically they begin to contract later in comparison with non-ischemic zones. There is a lack of information about methods that can detect dyssynchrony during exercise in patients with QRS not longer 100 ms. The aim of the study was to compare different methods of detection regarding left ventricular moving dyssynchrony in patients with significant coronary stenosis artery lesions: pulsed-wave of PW-TDI, strain (S) and strain rate (SR). The study included 133 subjects: 106 consecutive patients who were scheduled for coronary angiography with previous stress-echocardiography and 27 healthy persons. All the patients underwent a supine bicycle exercise test. Seventy-six patients had stenoses and 30 subjects had no significant lesions by coronary angiography. There was a detectable difference between time parameters of left ventricle contraction for the two groups and controls before and during exercise using all Doppler methods. Subgroups of patients without previous myocardial infarction and without hypertrophy of left ventricle had the same results. Maximal difference was observed using strain method. There was a moderate correlation between time parameters and the existence of significant lesions of coronary arteries. Patients without prolongations of QRS with significant lesions of coronary arteries have detectable left ventricular dyssynchrony before and during exercise.

  3. Dose-related ethanol intake, Cx43 and Nav1.5 remodeling: Exploring insights of altered ventricular conduction and QRS fragmentation in excessive alcohol users.

    PubMed

    Hung, Chung-Lieh; Lai, Yu-Jun; Chi, Po-Ching; Chen, Liang-Chia; Tseng, Ya-Ming; Kuo, Jen-Yuan; Lin, Cheng-I; Chen, Yao-Chang; Lin, Shing-Jong; Yeh, Hung-I

    2018-01-01

    Chronic, excessive ethanol intake has been linked with various electrical instabilities, conduction disturbances, and even sudden cardiac death, but the underlying cause for the latter is insufficiently delineated. We studied surface electrocardiography (ECG) in a community-dwelling cohort with moderate-to-heavy daily alcohol intake (grouped as >90g/day, ≤90g/day, and nonintake). Compared with nonintake, heavier alcohol users showed markedly widened QRS duration and higher prevalence of QRS fragmentation (64.3%, 50.9%, and 33.7%, respectively, χ 2 12.0, both p<0.05) on surface ECG across the 3 groups. These findings were successfully recapitulated in 14-week-old C57BL/6 mice that were chronically given a 4% or 6% alcohol diet and showed dose-related slower action potential upstroke, reduced resting membrane potential, and disorganized or decreased intraventricular conduction (all p<0.05). Immunodetection further revealed increased ventricular collagen I depots with Cx43 downregulation and remodeling, together with clustered and diminished membrane Nav1.5 distribution. Administration of Cx43 blocker (heptanol) and Nav1.5 inhibitor (tetrodotoxin) in the mice each attenuated the suppression ventricular conduction compared with nonintake mice (p<0.05). Chronic excessive alcohol ingestion is associated with dose-related phenotypic intraventricular conduction disturbances and QRS fragmentation that can be recapitulated in mice. The mechanisms may involve suppressed gap junction and sodium channel functions, together with enhanced cardiac fibrosis that may contribute to arrhythmogenesis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Wide QRS tachycardia: what is the rhythm?

    PubMed

    Rosman, Jonathan; Tawil, Joseph; Hanon, Sam; Schweitzer, Paul

    2006-10-01

    We report a case of an elderly man who presented to the emergency room complaining of palpitations. Electrocardiogram revealed wide QRS tachycardia with a narrow beat within the tachycardia. Most commonly, a narrow complex beat during a wide complex tachycardia suggests a capture or fusion beat in the setting of ventricular tachycardia. However, there are situations where supraventricular tachycardia can also manifest this way. In our patient a pacemaker interrogation clarified the diagnosis.

  5. A 300-mV 220-nW event-driven ADC with real-time QRS detection for wearable ECG sensors.

    PubMed

    Zhang, Xiaoyang; Lian, Yong

    2014-12-01

    This paper presents an ultra-low-power event-driven analog-to-digital converter (ADC) with real-time QRS detection for wearable electrocardiogram (ECG) sensors in wireless body sensor network (WBSN) applications. Two QRS detection algorithms, pulse-triggered (PUT) and time-assisted PUT (t-PUT), are proposed based on the level-crossing events generated from the ADC. The PUT detector achieves 97.63% sensitivity and 97.33% positive prediction in simulation on the MIT-BIH Arrhythmia Database. The t-PUT improves the sensitivity and positive prediction to 97.76% and 98.59% respectively. Fabricated in 0.13 μm CMOS technology, the ADC with QRS detector consumes only 220 nW measured under 300 mV power supply, making it the first nanoWatt compact analog-to-information (A2I) converter with embedded QRS detector.

  6. Low QRS Voltage on Presenting Electrocardiogram Predicts Multi-vessel Disease in Anterior ST-segment Elevation Myocardial Infarction.

    PubMed

    Kobayashi, Akihiro; Misumida, Naoki; Aoi, Shunsuke; Kanei, Yumiko

    Low QRS voltage was reported to predict adverse outcomes in acute myocardial infarction in the pre-thrombolytic era. However, the association between low voltage and angiographic findings has not been fully addressed. We performed a retrospective analysis of patients with anterior ST-segment elevation myocardial infarction (STEMI). Low QRS voltage was defined as either peak to peak QRS complex voltage <1.0mV in all precordial leads or <0.5mV in all limb leads. Among 190 patients, 37 patients (19%) had low voltage. Patients with low voltage had a higher rate of multi-vessel disease (MVD) (76% vs. 52%, p=0.01). Patients with low voltage were more likely to undergo coronary artery bypass grafting (CABG) during admission (11% vs. 2%, p=0.028). Low voltage was an independent predictor for MVD (OR 2.50; 95% CI 1.12 to 6.03; p=0.032). Low QRS voltage was associated with MVD and in-hospital CABG in anterior STEMI. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Analysis Spectrum of ECG Signal and QRS Detection during Running on Treadmill

    NASA Astrophysics Data System (ADS)

    Agung Suhendra, M.; Ilham R., M.; Simbolon, Artha I.; Faizal A., M.; Munandar, A.

    2018-03-01

    The heart is an important organ in our metabolism in which it controls circulatory and oxygen. The heart exercise is needed one of them using the treadmill to prevent health. To analysis, it using electrocardiograph (ECG) to investigating and diagnosing anomalies of the heart. In this paper, we would like to analysis ECG signals during running on the treadmill with kinds of speeds. There are two analysis ECG signals i.e. QRS detection and power spectrum density (PSD). The result of PSD showed that subject 3 has highly for all subject and the result of QRS detection using pan Tomkins algorithm that a percentage of failed detection is an approaching to 0 % for all subject.

  8. Tp-e Interval, Tp-e/QTc Ratio, and Fragmented QRS Are Correlated with the Severity of Liver Cirrhosis.

    PubMed

    Akboga, Mehmet Kadri; Yuksel, Mahmut; Balci, Kevser Gulcihan; Kaplan, Mustafa; Cay, Serkan; Gokbulut, Volkan; Yayla, Cagri; Ertem, Ahmet Goktug; Ayhan, Meral Akdogan; Topaloglu, Serkan; Aras, Dursun

    2017-01-01

    Arrhythmias and electrocardiographic changes are reported in several noncardiac diseases, including liver cirrhosis (LC). We intended to evaluate the interval from the peak to the end of the electrocardiographic T wave (Tp-e), Tp-e/QTc ratio, and fQRS as presumed markers of arrhythmias in LC. In this cross-sectional study, a total of 88 consecutive patients with LC according to clinical, biological, ultrasonographic, or histological criteria and 73 control subjects were enrolled. The severity of cirrhosis was classified according to Pugh-Child's classification and Model for End-Stage Liver Disease (MELD) score. Tp-e interval, Tp-e/QTc ratio, and fQRS rates were measured from the 12-lead electrocardiogram. Tp-e interval, Tp-e/QTc ratio and fQRS rates were significantly increased in parallel to the severity of LC (P < 0.001, P < 0.001, and P = 0.003, respectively). In correlation analysis, Pugh-Child stage showed a significantly positive correlation with Tp-e interval (r = 0.462, P < 0.001), QTc interval (r = 0.373, P < 0.001), Tp-e/QTc ratio (r = 0.352, P < 0.001), and fQRS (r = 0.407, P < 0.001). Furthermore, Tp-e interval (r = 0.414, P < 0.001) and Tp-e/QTc ratio (r = 0.426, P< 0.001) had significant positive correlation with MELD score. Our study demonstrated that Tp-e interval, Tp-e/QTc ratios, and fQRS rates were significantly increased in parallel to the severity of LC. Thus, these findings may implicate that Tp-e interval, Tp-e/QTc ratio, and fQRS may be novel and useful indicators for prediction of arrhythmias in LC. © 2016 Wiley Periodicals, Inc.

  9. Clinical and electrophysiological characteristics of patients with paroxysmal intra-His block with narrow QRS complexes.

    PubMed

    Ragupathi, Loheetha; Johnson, Drew; Greenspon, Arnold; Frisch, Daniel; Ho, Reginald T; Pavri, Behzad B

    2018-04-18

    Atrioventricular (AV) block is usually due to infranodal disease and associated with a wide QRS complex; such patients often progress to complete AV block and pacemaker dependency. Uncommonly, infranodal AV block can occur within the His bundle with a narrow QRS complex. The aims of this study were to define clinical/echocardiographic characteristics of patients with AV block within the His bundle and report progression to pacemaker dependency. We retrospectively identified patients with narrow QRS complexes and documented intra-His delay or block at electrophysiology study (group A) or with electrocardiogram-documented Mobitz II AV block/paroxysmal AV block (group B). Clinical, electrophysiological, and echocardiographic variables at presentation and pacemaker parameters at the last follow-up visit were evaluated. Twenty-seven patients (19 women) were identified (mean age 64 ± 13 years; range, 38-85 years). Four patients who had <1 month of follow-up were excluded. There were 12 patients in group A and 11 in group B; 21 of 23 presented with syncope/presyncope. All patients received pacemakers: 8 single chamber and 15 dual chamber. After a median follow-up of 6.4 years, the median percentage of ventricular pacing was 1% (interquartile range 0%-4.66%). One patient developed true pacemaker dependency. Aortic and/or mitral annular calcification was present in 13 of 22 patients with available echocardiograms. Patients who present with syncope and narrow QRS complexes with intra-His delay or Mobitz II paroxysmal AV block with narrow QRS complexes rarely progress to pacemaker dependency and require infrequent pacing. This entity is more common in women, with a higher prevalence of aortic and/or mitral annular calcification. If confirmed by additional studies, single-chamber pacemaker may be sufficient. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  10. QRS-fragmentation: Case report and review of the literature.

    PubMed

    Illescas-González, Edgar; Araiza-Garaygordobil, Diego; Sierra Lara, Jorge Daniel; Ramirez-Salazar, Aristoteles; Sierra-Fernández, Carlos; Alexanderson-Rosas, Erick

    Fragmentation of QRS complex (QRSf) is an easily evaluable, non-invasive electrocardiographic parameter that represents depolarisation anomalies and has been associated with several adverse outcomes, such as sudden death, fibrosis, arrhythmic burden, and a worse prognosis in different conditions, including coronary artery disease (CAD). The case is presented of a 69-year old male referred due to symptoms of chronic stable angina. His electrocardiogram showed sinus rhythm, absence of Q waves, but the presence of QRSf in the inferior leads and V4-V6. A Tc-99 myocardial perfusion SPECT scan revealed a fixed perfusion defect in the inferolateral region, corresponding to the finding of QRSf. QRSf is an easily valuable electrocardiographic marker with relative sensitivity, but poor specificity. Its routine clinical application could contribute to an increase in the suspicion of coronary artery disease. The presence of fragmented QRS represents distortion of signal conduction and depolarisation, which is related to myocardial scar or myocardial fibrosis. Copyright © 2016 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  11. Field programmable gate array based fuzzy neural signal processing system for differential diagnosis of QRS complex tachycardia and tachyarrhythmia in noisy ECG signals.

    PubMed

    Chowdhury, Shubhajit Roy

    2012-04-01

    The paper reports of a Field Programmable Gate Array (FPGA) based embedded system for detection of QRS complex in a noisy electrocardiogram (ECG) signal and thereafter differential diagnosis of tachycardia and tachyarrhythmia. The QRS complex has been detected after application of entropy measure of fuzziness to build a detection function of ECG signal, which has been previously filtered to remove power line interference and base line wander. Using the detected QRS complexes, differential diagnosis of tachycardia and tachyarrhythmia has been performed. The entire algorithm has been realized in hardware on an FPGA. Using the standard CSE ECG database, the algorithm performed highly effectively. The performance of the algorithm in respect of QRS detection with sensitivity (Se) of 99.74% and accuracy of 99.5% is achieved when tested using single channel ECG with entropy criteria. The performance of the QRS detection system has been compared and found to be better than most of the QRS detection systems available in literature. Using the system, 200 patients have been diagnosed with an accuracy of 98.5%.

  12. Real-Time 12-Lead High-Frequency QRS Electrocardiography for Enhanced Detection of Myocardial Ischemia and Coronary Artery Disease

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd T.; Kulecz, Walter B.; DePalma, Jude L.; Feiveson, Alan H.; Wilson, John S.; Rahman, M. Atiar; Bungo, Michael W.

    2004-01-01

    Several studies have shown that diminution of the high-frequency (HF; 150-250 Hz) components present within the central portion of the QRS complex of an electrocardiogram (ECG) is a more sensitive indicator for the presence of myocardial ischemia than are changes in the ST segments of the conventional low-frequency ECG. However, until now, no device has been capable of displaying, in real time on a beat-to-beat basis, changes in these HF QRS ECG components in a continuously monitored patient. Although several software programs have been designed to acquire the HF components over the entire QRS interval, such programs have involved laborious off-line calculations and postprocessing, limiting their clinical utility. We describe a personal computer-based ECG software program developed recently at the National Aeronautics and Space Administration (NASA) that acquires, analyzes, and displays HF QRS components in each of the 12 conventional ECG leads in real time. The system also updates these signals and their related derived parameters in real time on a beat-to-beat basis for any chosen monitoring period and simultaneously displays the diagnostic information from the conventional (low-frequency) 12-lead ECG. The real-time NASA HF QRS ECG software is being evaluated currently in multiple clinical settings in North America. We describe its potential usefulness in the diagnosis of myocardial ischemia and coronary artery disease.

  13. Real-Time, High-Frequency QRS Electrocardiograph

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd T.; DePalma, Jude L.; Moradi, Saeed

    2003-01-01

    An electronic system that performs real-time analysis of the low-amplitude, high-frequency, ordinarily invisible components of the QRS portion of an electrocardiographic signal in real time has been developed. Whereas the signals readily visible on a conventional electrocardiogram (ECG) have amplitudes of the order of a millivolt and are characterized by frequencies <100 Hz, the ordinarily invisible components have amplitudes in the microvolt range and are characterized by frequencies from about 150 to about 250 Hz. Deviations of these high-frequency components from a normal pattern can be indicative of myocardial ischemia or myocardial infarction

  14. [The relationship between fragmented QRS complex and coronary collateral circulation in patients with chronic total occlusion lesion without prior myocardial infarction].

    PubMed

    Gu, X J; Shan, S J; Liu, Z Z; Jin, G Z; Hu, Z Y; Zhu, L L; Zhang, J

    2017-04-24

    Objective: To explore the relationship between fragmented QRS complex(fQRS) and coronary collateral circulation(CCC) in patients with chronic total occlusion(CTO)lesion without prior myocardial infarction. Methods: This retrospective study analyzed 238 consecutive patients with CTO lesion in one of the major coronary arteries from May 2014 to October 2015 in our department. Patients were divided into poor CCC group (grade 0 and 1, 58 cases) and good CCC group(grade 2 and 3, 180 cases) based on Rentrop's classification of CCC. The fQRS was defined as the presence of an additional R wave or notching of R or S wave or the presence of fragmentation in two contiguous electrocardiogram leads corresponding to a major coronary artery territory. Multivariate logistic regression was used to analyze the relationship between CCC and fQRS on electrocardiogram. Results: Compared with good CCC group, patients in poor CCC group had older age((65.2±8.9)years old vs. (60.3±10.1) years old, P =0.03), higher plasma glucose ((7.22±3.00) mmol/L vs.(6.31±1.83)mmol/L, P =0.04), and lower left ventricular ejection fraction ((45.2±11.4)% vs. (51.2±13.5)%, P =0.02). None of patients had Rentrop grade 0, the presence of fQRS on ECG in patients with Rentrop grade 1, grade 2, and grade 3 CCC was 69.0% (40/58), 48.6% (35/72) , and 19.4% (21/108), respectively ( P <0.01). The presence of fQRS were higher in poor CCC group than in good CCC group (69.0%(40/58)vs. 31.1%(56/180), P <0.01), and number of leads with fQRS were higher in poor CCC group than in good CCC group (3(0, 4)vs.0(0, 3), P <0.01). Multivariate logistic regression analysis demonstrated that poor CCC growth in patients with CTO lesion without prior myocardial infarction was independently related to the presence of fQRS ( OR =3.659, 95% CI 1.619-8.217, P <0.01). Conclusion: Poor CCC in patients with CTO lesion without prior myocardial infarction is independently related to the presence of fQRS on electrocardiogram.

  15. Noninvasive fetal QRS detection using an echo state network and dynamic programming.

    PubMed

    Lukoševičius, Mantas; Marozas, Vaidotas

    2014-08-01

    We address a classical fetal QRS detection problem from abdominal ECG recordings with a data-driven statistical machine learning approach. Our goal is to have a powerful, yet conceptually clean, solution. There are two novel key components at the heart of our approach: an echo state recurrent neural network that is trained to indicate fetal QRS complexes, and several increasingly sophisticated versions of statistics-based dynamic programming algorithms, which are derived from and rooted in probability theory. We also employ a standard technique for preprocessing and removing maternal ECG complexes from the signals, but do not take this as the main focus of this work. The proposed approach is quite generic and can be extended to other types of signals and annotations. Open-source code is provided.

  16. Assessments of the QT/QRS restitution in perfused guinea-pig heart can discriminate safe and arrhythmogenic drugs.

    PubMed

    Osadchii, Oleg E

    2017-09-01

    Drug-induced arrhythmia remains a matter of serious clinical concern, partly due to low prognostic value of currently available arrhythmic biomarkers. This study examined whether arrhythmogenic risks can be predicted through assessments of the rate adaptation of QT interval, ventricular effective refractory period (ERP), or the QT/QRS ratio, in perfused guinea-pig hearts. When the maximum restitution slope was taken as a metric of proarrhythmia, neither QT interval nor ERP measurements at progressively increased pacing rates were found to fully discriminate arrhythmogenic drugs (dofetilide, quinidine, flecainide, and procainamide) from those recognized as safe antiarrhythmics (lidocaine and mexiletine). For example, the slope of QT restitution was increased by dofetilide and quinidine, but remained unchanged by flecainide, procainamide, lidocaine, and mexiletine. With ERP rate adaptation, even though the restitution slope was increased by dofetilide, all class I agents reduced the slope value independently of their safety profile. The QRS measurements revealed variable drug effects, ranging from significant use-dependent conduction slowing (flecainide, quinidine, and procainamide) to only modest increase in QRS (lidocaine and mexiletine), or no change at all (dofetilide). However, with the QT/QRS rate adaptation, the restitution slope was significantly increased by all agents which have been reported to produce proarrhythmic effects (dofetilide, quinidine, flecainide, and procainamide), but not changed by lidocaine and mexiletine. These findings suggest that the slope of the QT/QRS rate adaptation can be considered as a novel electrophysiological biomarker in predicting potential arrhythmic risks associated with pharmacotherapy in cardiac patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Fragmented QRS complex is a prognostic marker of microvascular reperfusion and changes in LV function occur in patients with ST elevation myocardial infarction who underwent primary percutaneous coronary intervention.

    PubMed

    Zhang, Ruoxi; Chen, Shuyuan; Zhao, Qi; Sun, Meng; Yu, Bo; Hou, Jingbo

    2017-06-01

    The present study aimed to investigate the in-hospital and long-term prognostic value of fragmented QRS complex (fQRS) for microvascular reperfusion and changes in left ventricular (LV) function in patients with ST elevation myocardial infarction (STEMI) who underwent primary percutaneous coronary intervention (PCI). A total of 216 patients with STEMI undergoing primary PCI were included in the current study. Patients were divided into two groups based on the presence (n=126) or absence (n=90) of fQRS following electrocardiograms (ECGs) on admission. Following primary PCI and follow up, patients were divided into four groups based on new onset, resolution, persistence and absence of fQRS. Major adverse cardiac events were defined to include cardiovascular death, arrhythmia, heart failure, reinfarction and target vessel revascularization. The percentage of patients with heart failure and microvascular reperfusion differed significantly between the fQRS(+) and fQRS(-) groups. Levels of N-terminal pro-brain natriuretic peptide (NT-proBNP), Peak creatine kinase-MB (CK-MB) and Troponin I levels were observed to be significantly higher in the fQRS(+) group compared with the fQRS(-) group. In univariate logistic regression analysis, left ventricular ejection fraction (LVEF), NT-proBNP, Troponin I, Peak CK-MB and microvascular reperfusion were found to be associated with fQRS. Multivariate analysis identified that LVEF, NT-proBNP, Troponin I and microvascular reperfusion may be independent predictors of fQRS. The presence of fQRS was demonstrated to be associated with left ventricular dysfunction at follow up assessments. The presence of fQRS was not only significantly associated with myocardial microvascular reperfusion and left ventricular function, but was also a prognostic marker in STEMI.

  18. [Electrocardiographic diagnosis: when QRS is wide.

    PubMed

    Conti, Matilde; Bregani, Enrico Rino

    2018-04-01

    Differential diagnosis of one or more wide QRS complexes on an electrocardiogram under emergency conditions takes into account three main sets of clinical conditions: ventricular pre-excitation, aberrant conduction and ventricular beats and it is based on the morphological analysis of the ECG and patient's anamnestic data. Several criteria can facilitate the differential diagnosis and if properly used and integrated with clinic data they can achieve good diagnostic accuracy in most cases. In this review several criteria based on evidence and literature are presented, paying attention in recognizing some morphologic pathways that can be used in emergency room and allow a correct ECG assessment.

  19. A real time QRS detection using delay-coordinate mapping for the microcontroller implementation.

    PubMed

    Lee, Jeong-Whan; Kim, Kyeong-Seop; Lee, Bongsoo; Lee, Byungchae; Lee, Myoung-Ho

    2002-01-01

    In this article, we propose a new algorithm using the characteristics of reconstructed phase portraits by delay-coordinate mapping utilizing lag rotundity for a real-time detection of QRS complexes in ECG signals. In reconstructing phase portrait the mapping parameters, time delay, and mapping dimension play important roles in shaping of portraits drawn in a new dimensional space. Experimentally, the optimal mapping time delay for detection of QRS complexes turned out to be 20 ms. To explore the meaning of this time delay and the proper mapping dimension, we applied a fill factor, mutual information, and autocorrelation function algorithm that were generally used to analyze the chaotic characteristics of sampled signals. From these results, we could find the fact that the performance of our proposed algorithms relied mainly on the geometrical property such as an area of the reconstructed phase portrait. For the real application, we applied our algorithm for designing a small cardiac event recorder. This system was to record patients' ECG and R-R intervals for 1 h to investigate HRV characteristics of the patients who had vasovagal syncope symptom and for the evaluation, we implemented our algorithm in C language and applied to MIT/BIH arrhythmia database of 48 subjects. Our proposed algorithm achieved a 99.58% detection rate of QRS complexes.

  20. Month-to-month and year-to-year reproducibility of high frequency QRS ECG signals

    NASA Technical Reports Server (NTRS)

    Batdorf, Niles J.; Feiveson, Alan H.; Schlegel, Todd T.

    2004-01-01

    High frequency electrocardiography analyzing the entire QRS complex in the frequency range of 150 to 250 Hz may prove useful in the detection of coronary artery disease, yet the long-term stability of these waveforms has not been fully characterized. Therefore, we prospectively investigated the reproducibility of the root mean squared voltage, kurtosis, and the presence versus absence of reduced amplitude zones in signal averaged 12-lead high frequency QRS recordings acquired in the supine position one month apart in 16 subjects and one year apart in 27 subjects. Reproducibility of root mean squared voltage and kurtosis was excellent over these time intervals in the limb leads, and acceptable in the precordial leads using both the V-lead and CR-lead derivations. The relative error of root mean squared voltage was 12% month-to-month and 16% year-to-year in the serial recordings when averaged over all 12 leads. Reduced amplitude zones were also reproducible up to a rate of 87% and 81%, respectively, for the month-to-month and year-to-year recordings. We conclude that 12-lead high frequency QRS electrocardiograms are sufficiently reproducible for clinical use.

  1. Month-to-Month and Year-to-Year Reproducibility of High Frequency QRS ECG signals

    NASA Technical Reports Server (NTRS)

    Batdorf, Niles; Feiveson, Alan H.; Schlegel, Todd T.

    2006-01-01

    High frequency (HF) electrocardiography analyzing the entire QRS complex in the frequency range of 150 to 250 Hz may prove useful in the detection of coronary artery disease, yet the long-term stability of these waveforms has not been fully characterized. We therefore prospectively investigated the reproducibility of the root mean squared (RMS) voltage, kurtosis, and the presence versus absence of reduced amplitude zones (RAzs) in signal averaged 12-lead HF QRS recordings acquired in the supine position one month apart in 16 subjects and one year apart in 27 subjects. Reproducibility of RMS voltage and kurtosis was excellent over these time intervals in the limb leads, and acceptable in the precordial leads using both the V-lead and CR-lead derivations. The relative error of RMS voltage was 12% month-to-month and 16% year-to-year in the serial recordings when averaged over all 12 leads. RAzs were also reproducible at a rate of up to 87% and 8 1 %, respectively, for the month-to-month and year-to-year recordings. We conclude that 12-lead HF QRS electrocardiograms are sufficiently reproducible for clinical use.

  2. Atrial fibrillation with wide QRS tachycardia and undiagnosed Wolff-Parkinson-White syndrome: diagnostic and therapeutic dilemmas in a pediatric patient.

    PubMed

    Panduranga, Prashanth; Al-Farqani, Abdullah; Al-Rawahi, Najib

    2012-11-01

    A 10-year-old girl presented to the emergency department of a regional hospital with 1 episode of generalized tonic-clonic seizures. Postictal monitoring followed by a 12-lead electrocardiogram showed fast atrial fibrillation with intermittent wide QRS regular tachycardia. Immediately following this, her rhythm changed to wide QRS irregular tachycardia without hemodynamic compromise. She was suspected to have ventricular tachycardia and was treated with intravenous amiodarone with cardioversion to sinus rhythm. Subsequent electrocardiogram in sinus rhythm showed typical features of manifest Wolff-Parkinson-White (WPW) accessory pathway. This case illustrates the diagnostic and therapeutic dilemmas in patients with atrial fibrillation, wide QRS tachycardia, and undiagnosed WPW syndrome with antidromic conduction of atrial arrhythmias through the accessory pathway. Furthermore, this case demonstrates that undiagnosed wide QRS tachycardias need to be treated with drugs acting on the accessory pathway, thus keeping in mind underlying WPW syndrome as a possibility to avoid potentially catastrophic events.

  3. Electrocardiographic parameters predict super-response in cardiac resynchronization therapy.

    PubMed

    Cvijić, Marta; Žižek, David; Antolič, Bor; Zupan, Igor

    2015-01-01

    Cardiac resynchronization therapy (CRT) is an established treatment for heart failure patients. However, determinants of response to CRT remain elusive. The aim of the study was to assess the value of ECG parameters to predict super-response in CRT patients. A 12-lead surface ECG was recorded at baseline and immediately after CRT-device implantation. Baseline ECG parameters (QRS duration, bundle branch morphology, axis, PR interval, QTc, intrinsicoid deflection) and post-implant paced QRS duration were analyzed; relative change in QRS duration was calculated. Decrease of left ventricular end-systolic volume ≥30% after 12 months was classified as super-response. In group of 101 patients, 32 (31.7%) were super-responders. There were no significant differences in baseline ECG parameters between super-responders and other patients. Post-implant QRS duration was shorter in super-responders (148 ± 22 ms vs. 162 ± 28 ms; P=0.010). Only in super-responders was significant QRS reduction observed after implantation. Relative QRS shortening was higher in super-responders (12.1% (6.8 to 22.2) vs. 1.7% (-11.9 to 11.8); P=0.005). In a multivariable analysis post-implant QRS duration and relative QRS shortening remained independent predictor of super-response. Absolute post-implant QRS duration and relative QRS shortening are the only ECG parameters associated with super-response in CRT. Further prospective studies on larger population are warranted to determine our findings. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. QRS Score at Presentation Electrocardiogram Is Correlated With Infarct Size and Mortality in ST-Segment Elevation Myocardial Infarction Patients Undergoing Primary Percutaneous Coronary Intervention.

    PubMed

    Shiomi, Hiroki; Kosuge, Masami; Morimoto, Takeshi; Watanabe, Hiroki; Taniguchi, Tomohiko; Nakatsuma, Kenji; Toyota, Toshiaki; Yamamoto, Erika; Shizuta, Satoshi; Tada, Tomohisa; Furukawa, Yutaka; Nakagawa, Yoshihisa; Ando, Kenji; Kadota, Kazushige; Kimura, Kazuo; Kimura, Takeshi

    2017-07-25

    In ST-segment elevation myocardial infarction (STEMI), QRS score at presentation ECG may reflect the progression of infarction and facilitate prediction of the degree of myocardial salvage achieved by reperfusion therapy.Methods and Results:Admission electrocardiogram (ECG) was studied in 2,607 patients with STEMI undergoing primary percutaneous coronary intervention (PCI) within 24 h of symptom onset. Patients were classified into 3 groups according to QRS score: low (0-3, n=1,227), intermediate (4-7, n=810), and high (≥8, n=570). An increase of infarct size estimated by median peak creatine phosphokinase was observed as QRS score increased (low score, 1,836 IU/L; inter-quartile range (IQR), 979-3,190 IU/L; intermediate score, 2,488 IU/L; IQR, 1,126-4,640 IU/L; high score, 3,454 IU/L; IQR, 1,759-5,639 IU/L; P<0.001). Higher QRS score was associated with higher long-term mortality (low, intermediate, and high score, 15.6%, 19.7%, and 23.7% at 5 years, respectively; log-rank P<0.001). The positive relationship of QRS score with mortality was consistently seen when stratified by infarct location. The association of high QRS score with increased mortality was most remarkably seen in patients with early (≤2 h) presentation (low, intermediate, and high score: 16.7%, 16.6%, and 28.1% at 5 years, respectively; log-rank P<0.001). Higher QRS score at presentation ECG was associated with larger infarct size, and higher long-term mortality in patients with STEMI undergoing primary PCI. QRS score appears to be important in the early risk stratification for STEMI.

  5. Real-time, high frequency QRS electrocardiograph with reduced amplitude zone detection

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd T. (Inventor); DePalma, Jude L. (Inventor); Moradi, Saeed (Inventor)

    2009-01-01

    Real time cardiac electrical data are received from a patient, manipulated to determine various useful aspects of the ECG signal, and displayed in real time in a useful form on a computer screen or monitor. The monitor displays the high frequency data from the QRS complex in units of microvolts, juxtaposed with a display of conventional ECG data in units of millivolts or microvolts. The high frequency data are analyzed for their root mean square (RMS) voltage values and the discrete RMS values and related parameters are displayed in real time. The high frequency data from the QRS complex are analyzed with imbedded algorithms to determine the presence or absence of reduced amplitude zones, referred to herein as ''RAZs''. RAZs are displayed as ''go, no-go'' signals on the computer monitor. The RMS and related values of the high frequency components are displayed as time varying signals, and the presence or absence of RAZs may be similarly displayed over time.

  6. Depolarization changes during acute myocardial ischemia by evaluation of QRS slopes: standard lead and vectorial approach.

    PubMed

    Romero, Daniel; Ringborn, Michael; Laguna, Pablo; Pahlm, Olle; Pueyo, Esther

    2011-01-01

    Diagnosis and risk stratification of patients with acute coronary syndromes can be improved by adding information from the depolarization phase (QRS complex) to the conventionally used ST-T segment changes. In this study, ischemia-induced changes in the main three slopes of the QRS complex, upward ( ℑ(US)) and downward ( ℑ(DS) ) slopes of the R wave as well as the upward ( ℑ(TS)) slope of the terminal S wave, were evaluated as to represent a robust measure of pathological changes within the depolarization phase. From ECG recordings both in a resting state (control recordings) and during percutaneous coronary intervention (PCI)-induced transmural ischemia, we developed a method for quantification of ℑ(US), ℑ(DS), and ℑ(TS) that incorporates dynamic ECG normalization so as to improve the sensitivity in the detection of ischemia-induced changes. The same method was also applied on leads obtained by projection of QRS loops onto their dominant directions. We show that ℑ(US), ℑ(DS), and ℑ(TS) present high stability in the resting state, thus providing a stable reference for ischemia characterization. Maximum relative factors of change ( ℜ(ℑ)) during PCI were found in leads derived from the QRS loop, reaching 10.5 and 13.7 times their normal variations in the control for ℑ(US) and ℑ(DS), respectively. For standard leads, the relative factors of change were 6.01 and 9.31. The ℑ(TS) index presented a similar behavior to that of ℑ(DS). The timing for the occurrence of significant changes in ℑ(US) and ℑ(DS) varied with lead, ranging from 30 s to 2 min after initiation of coronary occlusion. In the present ischemia model, relative ℑ(DS) changes were smaller than ST changes in most leads, however with only modest correlation between the two indices, suggesting they present different information about the ischemic process. We conclude that QRS slopes offer a robust tool for evaluating depolarization changes during myocardial ischemia.

  7. Ventricular conduction and long-term heart failure outcomes and mortality in African Americans: insights from the Jackson Heart Study.

    PubMed

    Mentz, Robert J; Greiner, Melissa A; DeVore, Adam D; Dunlay, Shannon M; Choudhary, Gaurav; Ahmad, Tariq; Khazanie, Prateeti; Randolph, Tiffany C; Griswold, Michael E; Eapen, Zubin J; O'Brien, Emily C; Thomas, Kevin L; Curtis, Lesley H; Hernandez, Adrian F

    2015-03-01

    QRS prolongation is associated with adverse outcomes in mostly white populations, but its clinical significance is not well established for other groups. We investigated the association between QRS duration and mortality in African Americans. We analyzed data from 5146 African Americans in the Jackson Heart Study stratified by QRS duration on baseline 12-lead ECG. We defined QRS prolongation as QRS≥100 ms. We assessed the association between QRS duration and all-cause mortality using Cox proportional hazards models and reported the cumulative incidence of heart failure hospitalization. We identified factors associated with the development of QRS prolongation in patients with normal baseline QRS. At baseline, 30% (n=1528) of participants had QRS prolongation. The cumulative incidences of mortality and heart failure hospitalization were greater with versus without baseline QRS prolongation: 12.6% (95% confidence interval [CI], 11.0-14.4) versus 7.1% (95% CI, 6.3-8.0) and 8.2% (95% CI, 6.9-9.7) versus 4.4% (95% CI, 3.7-5.1), respectively. After risk adjustment, QRS prolongation was associated with increased mortality (hazard ratio, 1.27; 95% CI, 1.03-1.56; P=0.02). There was a linear relationship between QRS duration and mortality (hazard ratio per 10 ms increase, 1.06; 95% CI, 1.01-1.12). Older age, male sex, prior myocardial infarction, lower ejection fraction, left ventricular hypertrophy, and left ventricular dilatation were associated with the development of QRS prolongation. QRS prolongation in African Americans was associated with increased mortality and heart failure hospitalization. Factors associated with developing QRS prolongation included age, male sex, prior myocardial infarction, and left ventricular structural abnormalities. © 2015 American Heart Association, Inc.

  8. Une tachycardie à QRS large mal tolérée chez un nourrisson

    PubMed Central

    Affangla, Désiré Alain; Leye, Mohamed; Simo, Angèle Wabo; D’Almeida, Franck; Sarr, Thérèse Yandé; Phiri, Adamson; Kane, Adama

    2017-01-01

    Les tachycardies à QRS large mal tolérées du nourrisson posent le problème de leur diagnostic et de la prise en charge en urgence. Nous rapportons un cas de tachycardie à QRS large chez un nourrisson de 35 jours reçu pour détresse cardio-circulatoire. Le cœur était morphologiquement normal à l’échographie cardiaque Doppler. Un traitement par une dose charge d’Amiodarone n’a pas permis de réduire cette tachycardie. Un retour en rythme sinusal a été obtenu après cardioversion par un défibrillateur externe semi-automatique type Lifeline. Un traitement d’entretien par Amiodarone per os est institué et le patient est en rythme sinusal à 03 mois. PMID:28904685

  9. Potential role of biventricular pacing beyond advanced systolic heart failure.

    PubMed

    Fang, Fang; Sanderson, John E; Yu, Cheuk-Man

    2013-01-01

    Cardiac resynchronization therapy (CRT) is an effective therapy for advanced heart failure (HF) patients. The indications are well defined in recent guidelines and broadly indicate that CRT is suitable for chronic HF patients with left ventricular ejection fraction (EF) ≤35% and in NYHA class III or IV (Class I), and those with prolonged QRS duration ≥120 ms with left bundle branch block (LBBB) QRS morphology, or QRS duration ≥150 ms irrespective of QRS morphology (Class IIa). For patients with NYHA class II symptoms, CRT is recommended for patients with EF ≤30% and QRS duration ≥130 ms with LBBB QRS morphology (Class I, level of evidence: A), or QRS duration ≥150 ms irrespective of QRS morphology (Class IIa, level of evidence: A). However, CRT may benefit additional patients outside these criteria. In this review, we summarize the role of CRT in some subgroups, including patients with mild and moderate HF, upgrading to CRT from right ventricular (RV) pacing, bradycardia patients with routine pacing indications, congenital heart disease and specific cardiomyopathies. It is possible that CRT can give symptomatic and mortality benefits in some of these subgroups in the future and further clinical trials are warranted.  

  10. Electrocardiogram voltage discordance: Interpretation of low QRS voltage only in the precordial leads.

    PubMed

    Kim, Diana H; Verdino, Ralph J

    To define clinical correlates of low voltage isolated to precordial leads on the surface electrocardiogram (ECG). Low voltage (V) on the ECG is defined as QRS V<5mm in all limb leads and <10mm in all precordial leads. The diagnostic use of ECGs with low voltage isolated to the precordial leads with normal limb lead voltages is unclear. Twelve-lead ECGs with QRS V>5mm in one or more limb leads and <10mm in all precordial leads were collected. Associated clinical conditions were determined from clinical data, echocardiograms, and chest radiographs. Low precordial voltage was found in 256 of 150,000 ECGs (~0.2%). 50.4% of patients had discordant ECGs that correlated with classic etiologies, with a higher incidence of LV dilation in those with classic etiologies than those without. Low precordial voltage is associated with classic etiologies and LV dilation. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Quick detection of QRS complexes and R-waves using a wavelet transform and K-means clustering.

    PubMed

    Xia, Yong; Han, Junze; Wang, Kuanquan

    2015-01-01

    Based on the idea of telemedicine, 24-hour uninterrupted monitoring on electrocardiograms (ECG) has started to be implemented. To create an intelligent ECG monitoring system, an efficient and quick detection algorithm for the characteristic waveforms is needed. This paper aims to give a quick and effective method for detecting QRS-complexes and R-waves in ECGs. The real ECG signal from the MIT-BIH Arrhythmia Database is used for the performance evaluation. The method proposed combined a wavelet transform and the K-means clustering algorithm. A wavelet transform is adopted in the data analysis and preprocessing. Then, based on the slope information of the filtered data, a segmented K-means clustering method is adopted to detect the QRS region. Detection of the R-peak is based on comparing the local amplitudes in each QRS region, which is different from other approaches, and the time cost of R-wave detection is reduced. Of the tested 8 records (total 18201 beats) from the MIT-BIH Arrhythmia Database, an average R-peak detection sensitivity of 99.72 and a positive predictive value of 99.80% are gained; the average time consumed detecting a 30-min original signal is 5.78s, which is competitive with other methods.

  12. [Basic mechanisms of QRS voltage changes on ECG of healthy subjects during the exercise test].

    PubMed

    Saltykova, M M

    2015-01-01

    Electrocardiography is the most commonly used technique for detection stress-induced myocardial ischemia. However, the sensitivity of ECG-criteria is not high. One of the major problem is the difficulty in differentiating ECG changes caused by various factors. The aim of this study was to evaluate the dependence of the QRS voltage changes during exercise on parameters of central hemodynamics, gender particularities and to reveal mechanisms causing these changes. To eliminate the effect of changes in cardiomyocytes transmembrane potentials under the influence of the neurotransmitters of the autonomic nervous system during stepwise increasing exercises and/or due to a lack of ATP results from inadequate myocardial blood flow only healthy subjects not older than 35 years were included in the study (7 men and 7 women) and only periods of ventricular depolarization (QRS complex on the ECG) were included in the analysis. We compared the changes of QRS waves during exercise sessions with two upper and one lower limbs in both men and women. The exercise load was twice bigger in exercise with one leg relative to exercise with two arms. Responses of heart rate and systolic arterial pressure were similar. Amplitude of S-wave in left chest leads significantly increased in both sessions without significant difference between augmentations in the sessions and in groups of men and women. Significant relationship between the S wave augmentation and the peak systolic arterial pressure were revealed. Furthermore, the QRS changes during the exercise with vertical and a horizontal torso position were compared to assess the impact of diastolic arterial pressure and displacement of the diaphragm and heart rotation due to increase of abdominal pressure during the last steps of exercise. The obtained results allow us to exclude the impact of the heart position and size changes, as well as the exercise load on S-wave changes and make a conclusion about the dependence of this parameter on

  13. Comparison of the QRS Complex, ST-Segment, and T-Wave Among Patients with Left Bundle Branch Block with and without Acute Myocardial Infarction.

    PubMed

    Dodd, Kenneth W; Elm, Kendra D; Smith, Stephen W

    2016-07-01

    The modified Sgarbossa criteria have been validated as a rule for diagnosis of acute coronary occlusion (ACO) in left bundle branch block (LBBB). However, no analysis has been done on differences in the QRS complex, T-wave, or ST-segment concordance of < 1 mm in the derivation or validation studies. Furthermore, there was no comparison of patients with acute myocardial infarction (AMI) but without ACO (i.e., non-ST-elevation myocardial infarction [non-STEMI]) to patients with ACO or without AMI (no MI). We compare findings involving the QRS amplitude, ST-segment morphology, ST-concordance < 1 mm, and T-waves in patients with LBBB with ACO, non-STEMI, and no MI. Retrospectively, emergency department patients were identified with LBBB and ischemic symptoms but no MI, with angiographically proven ACO, and with non-STEMI. ACO, non-STEMI, and no MI groups consisted of 33, 24, and 105 patients. The sum of the maximum deflection of the QRS amplitude across all leads (ΣQRS) was smaller in patients with ACO than those without ACO (101.5 mm vs. 132.5 mm; p < 0.0001) and a cutoff of ΣQRS < 90 mm was 92% specific. For ACO, non-concave ST-segment morphology was 91% specific, any ST concordance ≥ 1 mm was 95% specific, and any ST concordance ≥ 0.5 mm was 94% sensitive. For non-STEMI, terminal T-wave concordance, analogous to biphasic T-waves, was moderately sensitive at 79%. We found differences in QRS amplitude, ST-segment morphology, and T-waves between patients with LBBB and ACO, non-STEMI, and no MI. However, none of these criteria outperformed the modified Sgarbossa criteria for diagnosis of ACO in LBBB. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. The Use of Epicardial Electrogram as a Simple Guide to Select the Optimal Site of Left Ventricular Pacing in Cardiac Resynchronization Therapy

    PubMed Central

    Fatemi, Marjaneh; Le Gal, Grégoire; Blanc, Jean-Jacques; Mansourati, Jacques; Etienne, Yves

    2011-01-01

    Cardiac resynchronization therapy (CRT) has been demonstrated to improve symptoms and survival in patients with left ventricular (LV) systolic dysfunction and dyssynchrony. To achieve this goal, the LV lead should be positioned in a region of delayed contraction. We hypothesized that pacing at the site of late electrical activation was also associated with long-term response to CRT. We conducted a retrospective study on 72 CRT patients. For each patient, we determined the electrical delay (ED) from the onset of QRS to the epicardial EGM and the ratio of ED to QRS duration (ED/QRS duration). After a followup of 30 ± 20 months, 47 patients responded to CRT. Responders had a significantly longer ED and greater ratio of ED/QRS duration than nonresponders. An ED/QRS duration ≥0.38 predicted a response to CRT with 89% specificity and 53% sensitivity. PMID:21403903

  15. An individual patient meta-analysis of five randomized trials assessing the effects of cardiac resynchronization therapy on morbidity and mortality in patients with symptomatic heart failure.

    PubMed

    Cleland, John G; Abraham, William T; Linde, Cecilia; Gold, Michael R; Young, James B; Claude Daubert, J; Sherfesee, Lou; Wells, George A; Tang, Anthony S L

    2013-12-01

    Cardiac resynchronization therapy (CRT) with or without a defibrillator reduces morbidity and mortality in selected patients with heart failure (HF) but response can be variable. We sought to identify pre-implantation variables that predict the response to CRT in a meta-analysis using individual patient-data. An individual patient meta-analysis of five randomized trials, funded by Medtronic, comparing CRT either with no active device or with a defibrillator was conducted, including the following baseline variables: age, sex, New York Heart Association class, aetiology, QRS morphology, QRS duration, left ventricular ejection fraction (LVEF), and systolic blood pressure. Outcomes were all-cause mortality and first hospitalization for HF or death. Of 3782 patients in sinus rhythm, median (inter-quartile range) age was 66 (58-73) years, QRS duration was 160 (146-176) ms, LVEF was 24 (20-28)%, and 78% had left bundle branch block. A multivariable model suggested that only QRS duration predicted the magnitude of the effect of CRT on outcomes. Further analysis produced estimated hazard ratios for the effect of CRT on all-cause mortality and on the composite of first hospitalization for HF or death that suggested increasing benefit with increasing QRS duration, the 95% confidence bounds excluding 1.0 at ∼140 ms for each endpoint, suggesting a high probability of substantial benefit from CRT when QRS duration exceeds this value. QRS duration is a powerful predictor of the effects of CRT on morbidity and mortality in patients with symptomatic HF and left ventricular systolic dysfunction who are in sinus rhythm. QRS morphology did not provide additional information about clinical response. NCT00170300, NCT00271154, NCT00251251.

  16. QRS Width as a Predictor of Right Ventricular Remodeling After Percutaneous Pulmonary Valve Implantation.

    PubMed

    Paech, C; Dähnert, I; Riede, F T; Wagner, R; Kister, T; Nieschke, K; Wagner, F; Gebauer, R A

    2017-08-01

    Recent data showed a right ventricular dyssynchrony in patients with tetralogy of Fallot (TOF). Percutaneous pulmonary valve implantation (PPVI) has become an important procedure to treat a pulmonary stenosis and/or regurgitation of the right ventricular outflow tract in these patients. Despite providing good results, there is still a considerable number of nonresponders to PPVI. The authors speculated that electrical dysfunction of the right ventricle plays an underestimated role in the outcome of patients after PPVI. This study aimed to investigate the influence of right ventricular electrical dysfunction, i.e., right bundle branch block (RBBB) on the RV remodeling after PPVI. The study included consecutive patients after correction of TOF with or without RBBB, who had received a PPVI previously at the Heart Center of the University of Leipzig, Germany during the period from 2012 to 2015. 24 patients were included. Patients without RBBB, i.e., with narrow QRS complexes pre-intervention, had significantly better RV function and had smaller right ventricular volumes. Patients with pre-interventionally QRS width below 150 ms showed a post-interventional remodeling of the right ventricle with the decreasing RV volumes (p = 0.001). The parameters of LV function and volume as well as RV ejection fraction remained unaffected by RBBB. The presented data indicate that the QRS width seems to be a valuable parameter in the prediction of right ventricular remodeling after PPVI, as it represents both electrical and mechanical functions of the right ventricle and may serve as an additional parameter for optimal timing of a PPVI.

  17. Prognostic significance of inverse spatial QRS-T angle circadian pattern in myocardial infarction survivors.

    PubMed

    Giannopoulos, Georgios; Dilaveris, Polychronis; Batchvarov, Velislav; Synetos, Andreas; Hnatkova, Katerina; Gatzoulis, Konstantinos; Malik, Marek; Stefanadis, Christodoulos

    2009-01-01

    We investigated the predictive value of the spatial QRS-T angle (QRSTA) circadian variation in myocardial infarction (MI) patients. Analyzing 24-hour recordings (SEER MC, GE Marquette) from 151 MI patients (age 63 +/- 12.7), the QRSTA was computed in derived XYZ leads. QRS-T angle values were compared between daytime and night time. The end point was cardiac death or life-threatening ventricular arrhythmia in 1 year. Overall, QRSTA was slightly higher during the day vs. the night (91 degrees vs. 87 degrees, P = .005). However, 33.8% of the patients showed an inverse diurnal QRSTA variation (higher values at night), which was correlated to the outcome (P = .001, odds ratio 6.7). In multivariate analysis, after entering all factors exhibiting univariate trend towards significance, inverse QRSTA circadian pattern remained significant (P = .036). Inverse QRSTA circadian pattern was found to be associated with adverse outcome (22.4%) in MI patients, whereas a normal pattern was associated (96%) with a favorable outcome.

  18. [Wide QRS tachycardia preceded by pacemaker spikes].

    PubMed

    Romero, M; Aranda, A; Gómez, F J; Jurado, A

    2014-04-01

    The differential diagnosis and therapeutic management of wide QRS tachycardia preceded by pacemaker spike is presented. The pacemaker-mediated tachycardia, tachycardia fibrillo-flutter in patients with pacemakers, and runaway pacemakers, have a similar surface electrocardiogram, but respond to different therapeutic measures. The tachycardia response to the application of a magnet over the pacemaker could help in the differential diagnosis, and in some cases will be therapeutic, as in the case of a tachycardia-mediated pacemaker. Although these conditions are diagnosed and treated in hospitals with catheterization laboratories using the application programmer over the pacemaker, patients presenting in primary care clinic and emergency forced us to make a diagnosis and treat the haemodynamically unstable patient prior to referral. Copyright © 2012 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.

  19. Electrocardiogram of Clinically Healthy Mithun (Bos frontalis): Variation among Strains

    PubMed Central

    Sanyal, Sagar; Das, Pradip Kumar; Ghosh, Probal Ranjan; Das, Kinsuk; Vupru, Kezha V.; Rajkhowa, Chandan; Mondal, Mohan

    2010-01-01

    A study was conducted to establish the normal electrocardiogram in four different genetic strains of mithun (Bos frontalis). Electrocardiography, cardiac electrical axis, heart rate, rectal temperature and respiration rate were recorded in a total of 32 adult male mithun of four strains (n = 8 each). It was found that the respiration and heart rates were higher (P < .05) in Manipur than other three strains. Amplitude (P < .05) and duration of P wave and QRS complex differed (P < .01) among the strains. Mizoram strain had the highest amplitude and duration of P wave and QRS complex. On the other hand, higher (P < .05) amplitude and duration of T wave were recorded in Arunachalee and Mizoram strains. The mean electrical axis of QRS complex that were recorded for Arunachalee and Manipur strains were similar to that reported for other bovine species; whereas the electrical axis of QRS for Nagamese and Mizoram strains were more close to feline and caprine species, respectively. In conclusion, electrocardiogram of mithun revealed that the amplitude and duration of P wave, QRS complex and T wave were different among four different genetic strains of mithun and the electrical axis of QRS complex for Nagamese and Mizoram mithuns are dissimilar to bovine species. PMID:20886013

  20. Perspectives of human verification via binary QRS template matching of single-lead and 12-lead electrocardiogram.

    PubMed

    Krasteva, Vessela; Jekova, Irena; Schmid, Ramun

    2018-01-01

    This study aims to validate the 12-lead electrocardiogram (ECG) as a biometric modality based on two straightforward binary QRS template matching characteristics. Different perspectives of the human verification problem are considered, regarding the optimal lead selection and stability over sample size, gender, age, heart rate (HR). A clinical 12-lead resting ECG database, including a population of 460 subjects with two-session recordings (>1 year apart) is used. Cost-effective strategies for extraction of personalized QRS patterns (100ms) and binary template matching estimate similarity in the time scale (matching time) and dissimilarity in the amplitude scale (mismatch area). The two-class person verification task, taking the decision to validate or to reject the subject identity is managed by linear discriminant analysis (LDA). Non-redundant LDA models for different lead configurations (I,II,III,aVF,aVL,aVF,V1-V6) are trained on the first half of 230 subjects by stepwise feature selection until maximization of the area under the receiver operating characteristic curve (ROC AUC). The operating point on the training ROC at equal error rate (EER) is tested on the independent dataset (second half of 230 subjects) to report unbiased validation of test-ROC AUC and true verification rate (TVR = 100-EER). The test results are further evaluated in groups by sample size, gender, age, HR. The optimal QRS pattern projection for single-lead ECG biometric modality is found in the frontal plane sector (60°-0°) with best (Test-AUC/TVR) for lead II (0.941/86.8%) and slight accuracy drop for -aVR (-0.017/-1.4%), I (-0.01/-1.5%). Chest ECG leads have degrading accuracy from V1 (0.885/80.6%) to V6 (0.799/71.8%). The multi-lead ECG improves verification: 6-chest (0.97/90.9%), 6-limb (0.986/94.3%), 12-leads (0.995/97.5%). The QRS pattern matching model shows stable performance for verification of 10 to 230 individuals; insignificant degradation of TVR in women by (1.2-3.6%), adults

  1. Development of a Multi-Channel, High Frequency QRS Electrocardiograph

    NASA Technical Reports Server (NTRS)

    DePalma, Jude L.

    2003-01-01

    With the advent of the ISS era and the potential requirement for increased cardiovascular monitoring of crewmembers during extended EVAs, NASA flight surgeons would stand to benefit from an evolving technology that allows for a more rapid diagnosis of myocardial ischemia compared to standard electrocardiography. Similarly, during the astronaut selection process, NASA flight surgeons and other physicians would also stand to benefit from a completely noninvasive technology that, either at rest or during maximal exercise tests, is more sensitive than standard ECG in identifying the presence of ischemia. Perhaps most importantly, practicing cardiologists and emergency medicine physicians could greatly benefit from such a device as it could augment (or even replace) standard electrocardiography in settings where the rapid diagnosis of myocardial ischemia (or the lack thereof) is required for proper clinical decision-making. A multi-channel, high-frequency QRS electrocardiograph is currently under development in the Life Sciences Research Laboratories at JSC. Specifically the project consisted of writing software code, some of which contained specially-designed digital filters, which will be incorporated into an existing commercial software program that is already designed to collect, plot and analyze conventional 12-lead ECG signals on a desktop, portable or palm PC. The software will derive the high-frequency QRS signals, which will be analyzed (in numerous ways) and plotted alongside of the conventional ECG signals, giving the PC-viewing clinician advanced diagnostic information that has never been available previously in all 12 ECG leads simultaneously. After the hardware and software for the advanced digital ECG monitor have been fully integrated, plans are to use the monitor to begin clinical studies both on healthy subjects and on patients with known coronary artery disease in both the outpatient and hospital settings. The ultimate goal is to get the technology

  2. Left ventricular outflow tract arrhythmias with divergent QRS morphology: mapping of different exits and ablation strategy.

    PubMed

    Reithmann, Christopher; Fiek, Michael

    2018-01-01

    Ventricular arrhythmias (VAs) from the left ventricular outflow tract (LVOT) can have multiple exits exhibiting divergent ECG features. In a series of 131 patients with VAs with LVOT origin, 10 patients presented with divergent QRS morphologies. Multisite endo- and epicardial mapping of different exit sites was performed. The earliest ventricular activity of 23 LVOT VAs in 10 patients was detected in the endocardium of the LV in 7 patients, the aortic sinuses of Valsalva (SoV) in 3 patients, the distal coronary sinus in 6 patients, the anterior interventricular vein in 3 patients, and the posterior right ventricular outflow tract (RVOT) in 4 patients. Simultaneous elimination of two divergent QRS morphologies of LVOT VAs by ablation from a single site was achieved in 5 patients (aorto-mitral continuity in 3 patients, SoV and RVOT in each 1 patient) using a mean maximum ablation energy of 46 ± 5 W. Sequential ablation from two or three different sites, including trans-pericardial and distal coronary sinus ablation in each 2 patients, led to elimination of the divergent VA QRS morphologies in the other 5 patients. During the follow-up of 28 ± 29 months, 4 of the 10 patients had recurrence of at least one LVOT VA. A 43-year-old patient with muscular dystrophy Curschmann-Steinert had recurrence of sustained LVOT VTs and died of sudden cardiac death. Multisite mapping of different exit sites of LVOT VAs can guide ablation of intramural foci but the recurrence rate after initially successful ablation was high.

  3. The roles of the Q (q) wave in lead I and QRS frontal axis for diagnosing loss of left ventricular capture during cardiac resynchronization therapy.

    PubMed

    Cao, Yuan-Yuan; Su, Yan-Gang; Bai, Jin; Wang, Wei; Wang, Jing-Feng; Qin, Sheng-Mei; Ge, Jun-Bo

    2015-01-01

    Loss of left ventricular (LV) capture may lead to deterioration of heart failure in patients with cardiac resynchronization therapy (CRT). Recognition of loss of LV capture in time is important in clinical practice. A total of 422 electrocardiograms were acquired and analyzed from 53 CRT patients at 8 different pacing settings (LV only, right ventricle [RV] only, biventricular [BV] pacing with LV preactivation of 60, 40, 20, and 0 milliseconds and RV preactivation of 20 and 40 milliseconds). A modified Ammann algorithm by adding a third step-presence of Q (q, or QS) wave-to the original 2-step Ammann algorithm and a QRS axis shift method were devised to identify the loss of LV capture. The accuracy of modified Ammann algorithm was significantly higher than that of Ammann algorithm (78.9% vs. 69.1%, P < 0.001). The accuracy of the axis shift method was 66.4%, which was significantly lower than the modified Ammann algorithm (P < 0.001) and similar to the original one (P = 0.412). However, in the ECGs with QRS axis shift, 96.8% were correctly classified. LV preactivation or simultaneous BV activation and LV lead positioned in nonposterior or noninferior wall could elevate the accuracies of the modified Ammann algorithm and the QRS axis shift method. The accuracy of the modified Ammann algorithm is greatly improved. The QRS axis shift method can help diagnose LV capture. The LV preactivation, or simultaneous BV activation and LV lead positioned in nonposterior or noninferior wall can increase the diagnostic power of the modified Ammann algorithm and QRS axis shift method. © 2014 Wiley Periodicals, Inc.

  4. Wolff-Parkinson-White (WPW) syndrome: the detection of delta wave in an electrocardiogram (ECG).

    PubMed

    Mahamat, Hassan Adam; Jacquir, Sabir; Khalil, Cliff; Laurent, Gabriel; Binczak, Stephane

    2016-08-01

    The delta wave remains an important indicator to diagnose the WPW syndrome. In this paper, a new method of detection of delta wave in an ECG signal is proposed. Firstly, using the continuous wavelet transform, the P wave, the QRS complex and the T wave are detected, then their durations are computed after determination of the boundary location (onsets and offsets of the P, QRS and T waves). Secondly, the PR duration, the QRS duration and the upstroke of the QRS complex are used to determine the presence or absence of the delta wave. This algorithm has been tested on the Physionel database (ptbdb) in order to evaluate its robustness. It has been applied to clinical signals from patients affected by WPW syndrome. This method can provide assistance to practitioners in order to detect the WPW syndrome.

  5. Diagnostic electrocardiographic dyad criteria of emphysema in left ventricular hypertrophy

    PubMed Central

    Lanjewar, Swapnil S; Chhabra, Lovely; Chaubey, Vinod K; Joshi, Saurabh; Kulkarni, Ganesh; Kothagundla, Chandrasekhar; Kaul, Sudesh; Spodick, David H

    2013-01-01

    Background The electrocardiographic diagnostic dyad of emphysema, namely a combination of the frontal vertical P-vector and a narrow QRS duration, can serve as a quasidiagnostic marker for emphysema, with specificity close to 100%. We postulated that the presence of left ventricular hypertrophy in emphysema may affect the sensitivity of this electrocardiographic criterion given that left ventricular hypertrophy generates prominent left ventricular forces and may increase the QRS duration. Methods We reviewed the electrocardiograms and echocardiograms for 73 patients with emphysema. The patients were divided into two groups based on the presence or absence of echocardiographic evidence of left ventricular hypertrophy. The P-vector, QRS duration, and forced expiratory volume in one second (FEV1) were computed and compared between the two subgroups. Results There was no statistically significant difference in qualitative lung function (FEV1) between the subgroups. There was no statistically significant difference in mean P-vector between the subgroups. The mean QRS duration was significantly longer in patients with left ventricular hypertrophy as compared with those without left ventricular hypertrophy. Conclusion The presence of left ventricular hypertrophy may not affect the sensitivity of the P-vector verticalization when used as a lone criterion for diagnosing emphysema. However, the presence of left ventricular hypertrophy may significantly reduce the sensitivity of the electrocardiographic diagnostic dyad in emphysema, as it causes a widening of the QRS duration. PMID:24293995

  6. Diagnostic electrocardiographic dyad criteria of emphysema in left ventricular hypertrophy.

    PubMed

    Lanjewar, Swapnil S; Chhabra, Lovely; Chaubey, Vinod K; Joshi, Saurabh; Kulkarni, Ganesh; Kothagundla, Chandrasekhar; Kaul, Sudesh; Spodick, David H

    2013-01-01

    The electrocardiographic diagnostic dyad of emphysema, namely a combination of the frontal vertical P-vector and a narrow QRS duration, can serve as a quasidiagnostic marker for emphysema, with specificity close to 100%. We postulated that the presence of left ventricular hypertrophy in emphysema may affect the sensitivity of this electrocardiographic criterion given that left ventricular hypertrophy generates prominent left ventricular forces and may increase the QRS duration. We reviewed the electrocardiograms and echocardiograms for 73 patients with emphysema. The patients were divided into two groups based on the presence or absence of echocardiographic evidence of left ventricular hypertrophy. The P-vector, QRS duration, and forced expiratory volume in one second (FEV1) were computed and compared between the two subgroups. There was no statistically significant difference in qualitative lung function (FEV1) between the subgroups. There was no statistically significant difference in mean P-vector between the subgroups. The mean QRS duration was significantly longer in patients with left ventricular hypertrophy as compared with those without left ventricular hypertrophy. The presence of left ventricular hypertrophy may not affect the sensitivity of the P-vector verticalization when used as a lone criterion for diagnosing emphysema. However, the presence of left ventricular hypertrophy may significantly reduce the sensitivity of the electrocardiographic diagnostic dyad in emphysema, as it causes a widening of the QRS duration.

  7. Cardiac conductive disturbance in patients with polycystic ovary syndrome.

    PubMed

    Huang, Jen-Hung; Tsai, Jen-Chen; Hsu, Ming-I; Chen, Yi-Jen

    2010-12-01

    Polycystic ovary syndrome (PCOS) is the most common endocrine abnormality of reproductive-aged women and increases the risk of cardiovascular disease. However, the effects of PCOS on electrocardiograms (ECGs) are not fully elucidated. The aim of this study was to evaluate the characteristics of ECGs in patients with PCOS. This study included 24 patients with PCOS and 12 patients without PCOS. The heart rate, PR interval, QRS duration, Sokolow-Lyon voltage (SV1 + RV5/6), Cornell voltage (RaVL + SV3), QT interval and QTc interval were measured in 12-lead ECGs. The QRS duration was wider in patients with PCOS than those without PCOS (91 ± 8 vs. 81 ± 10 ms, p < 0.05). The heart rate, PR interval, Sokolow-Lyon voltage, product of the QRS duration times Cornell voltage combination, QT interval, QTc interval, QT dispersion and QTc dispersion were similar between the two groups. PCOS is associated with a widening QRS duration, which may contribute to its increased cardiovascular risks.

  8. Echocardiographic evaluation of cardiac dyssynchrony in patients with congestive heart failure.

    PubMed

    Qin, Chuan; Zhang, Li; Zhang, Zi-Ming; Wang, Bin; Ye, Zhou; Wang, Yong; Nanda, Navin C; Xie, Ming-Xing

    2016-06-01

    The present study investigated the application of echocardiography to evaluation of cardiac dyssynchrony in patients with congestive heart failure (CHF). A total of 348 consecutive CHF patients who were admitted for cardiac resynchronization (CRT) and presented with low ejection fraction (EF) and wide QRS duration were enrolled in this study, along with 388 healthy individuals. Dyssynchrony was assessed based on filling time ratio (FT/RR), left ventricular pre-ejection delay (PED), interventricular mechanical delay (IVMD), longitudinal opposing wall delay (LOWD) and radial septal to posterior wall delay (RSPWD). Response to CRT was defined as a ≥15% increase in EF. The results showed that FT/RR was decreased while PED, IVMD, LOWD and RSPWD were increased in the CHF group compared with the control group (P<0.01). In the CHF group, FT/RR was negatively correlated with the QRS duration, LV end-diastolic diameter (LVESd), LV end-diastolic volume (LVEDV) and LV end-systolic volume (LVESV) (P<0.01), but positively with the LVEF (P<0.01). Additionally, PED, IVMD, LOWD and RSPWD were positively correlated with the QRS duration, LVESd, LVEDV and LVESV (P<0.01), but negatively with the LVEF (P<0.01). The CHF group was divided into three subgroups according to the varying degrees of LVEF. FT/RR decreased successively from the LVEF-1 group to the LVEF-2 group to the LVEF-3 group, while the PED, IVMD, LOWD and RSPWD successively increased in the same order (P<0.01). The CHF group was divided into three subgroups according to the varying degrees of QRS duration, and FT/RR decreased successively in a sequence from the QRS-1 group to the QRS-2 group to the QRS-3 group, while the PED, IVMD, LOWD and RSPWD successively increased in the same order (P<0.01). Speckle tracking radial dyssynchrony ≥130 ms was predictive of an EF response in patients in QRS-1 group (78% sensitivity, 83% specificity), those in QRS-2 group (83% sensitivity, 77% specificity) and in QRS-3 group (89

  9. Analysis of the High-Frequency Content in Human QRS Complexes by the Continuous Wavelet Transform: An Automatized Analysis for the Prediction of Sudden Cardiac Death.

    PubMed

    García Iglesias, Daniel; Roqueñi Gutiérrez, Nieves; De Cos, Francisco Javier; Calvo, David

    2018-02-12

    Fragmentation and delayed potentials in the QRS signal of patients have been postulated as risk markers for Sudden Cardiac Death (SCD). The analysis of the high-frequency spectral content may be useful for quantification. Forty-two consecutive patients with prior history of SCD or malignant arrhythmias (patients) where compared with 120 healthy individuals (controls). The QRS complexes were extracted with a modified Pan-Tompkins algorithm and processed with the Continuous Wavelet Transform to analyze the high-frequency content (85-130 Hz). Overall, the power of the high-frequency content was higher in patients compared with controls (170.9 vs. 47.3 10³nV²Hz -1 ; p = 0.007), with a prolonged time to reach the maximal power (68.9 vs. 64.8 ms; p = 0.002). An analysis of the signal intensity (instantaneous average of cumulative power), revealed a distinct function between patients and controls. The total intensity was higher in patients compared with controls (137.1 vs. 39 10³nV²Hz -1 s -1 ; p = 0.001) and the time to reach the maximal intensity was also prolonged (88.7 vs. 82.1 ms; p < 0.001). The high-frequency content of the QRS complexes was distinct between patients at risk of SCD and healthy controls. The wavelet transform is an efficient tool for spectral analysis of the QRS complexes that may contribute to stratification of risk.

  10. Analysis of the High-Frequency Content in Human QRS Complexes by the Continuous Wavelet Transform: An Automatized Analysis for the Prediction of Sudden Cardiac Death

    PubMed Central

    García Iglesias, Daniel; Roqueñi Gutiérrez, Nieves; De Cos, Francisco Javier; Calvo, David

    2018-01-01

    Background: Fragmentation and delayed potentials in the QRS signal of patients have been postulated as risk markers for Sudden Cardiac Death (SCD). The analysis of the high-frequency spectral content may be useful for quantification. Methods: Forty-two consecutive patients with prior history of SCD or malignant arrhythmias (patients) where compared with 120 healthy individuals (controls). The QRS complexes were extracted with a modified Pan-Tompkins algorithm and processed with the Continuous Wavelet Transform to analyze the high-frequency content (85–130 Hz). Results: Overall, the power of the high-frequency content was higher in patients compared with controls (170.9 vs. 47.3 103nV2Hz−1; p = 0.007), with a prolonged time to reach the maximal power (68.9 vs. 64.8 ms; p = 0.002). An analysis of the signal intensity (instantaneous average of cumulative power), revealed a distinct function between patients and controls. The total intensity was higher in patients compared with controls (137.1 vs. 39 103nV2Hz−1s−1; p = 0.001) and the time to reach the maximal intensity was also prolonged (88.7 vs. 82.1 ms; p < 0.001). Discussion: The high-frequency content of the QRS complexes was distinct between patients at risk of SCD and healthy controls. The wavelet transform is an efficient tool for spectral analysis of the QRS complexes that may contribute to stratification of risk. PMID:29439530

  11. Stream computing for biomedical signal processing: A QRS complex detection case-study.

    PubMed

    Murphy, B M; O'Driscoll, C; Boylan, G B; Lightbody, G; Marnane, W P

    2015-01-01

    Recent developments in "Big Data" have brought significant gains in the ability to process large amounts of data on commodity server hardware. Stream computing is a relatively new paradigm in this area, addressing the need to process data in real time with very low latency. While this approach has been developed for dealing with large scale data from the world of business, security and finance, there is a natural overlap with clinical needs for physiological signal processing. In this work we present a case study of streams processing applied to a typical physiological signal processing problem: QRS detection from ECG data.

  12. Association between obesity and ECG variables in children and adolescents: A cross-sectional study.

    PubMed

    Sun, Guo-Zhe; Li, Yang; Zhou, Xing-Hu; Guo, Xiao-Fan; Zhang, Xin-Gang; Zheng, Li-Qiang; Li, Yuan; Jiao, Yun-DI; Sun, Ying-Xian

    2013-12-01

    Obesity exhibits a wide variety of electrocardiogram (ECG) abnormalities in adults, which often lead to cardiovascular events. However, there is currently no evidence of an association between obesity and ECG variables in children and adolescents. The present study aimed to explore the associations between obesity and ECG intervals and axes in children and adolescents. A cross-sectional observational study of 5,556 students aged 5-18 years was performed. Anthropometric data, blood pressure and standard 12-lead ECGs were collected for each participant. ECG variables were measured manually based on the temporal alignment of simultaneous 12 leads using a CV200 ECG Work Station. Overweight and obese groups demonstrated significantly longer PR intervals, wider QRS durations and leftward shifts of frontal P-wave, QRS and T-wave axes, while the obese group also demonstrated significantly higher heart rates, compared with normal weight groups within normotensive or hypertensive subjects (P<0.05). Abdominal obesity was also associated with longer PR intervals, wider QRS duration and a leftward shift of frontal ECG axes compared with normal waist circumference (WC) within normotensive or hypertensive subjects (P<0.05). Gender was a possible factor affecting the ECG variables. Furthermore, the ECG variables, including PR interval, QRS duration and frontal P-wave, QRS and T-wave axes, were significantly linearly correlated with body mass index, WC and waist-to-height ratio adjusted for age, gender, ethnicity and blood pressure. However, there was no significant association between obesity and the corrected QT interval (P>0.05). The results of the current study indicate that in children and adolescents, general and abdominal obesity is associated with longer PR intervals, wider QRS duration and a leftward shift of frontal P-wave, QRS and T-wave axes, independent of age, gender, ethnicity and blood pressure.

  13. Dynamic Changes of QRS Morphology of Premature Ventricular Contractions During Ablation in the Right Ventricular Outflow Tract: A Case Report.

    PubMed

    Yue-Chun, Li; Jia-Feng, Lin; Jia-Xuan, Lin

    2015-10-01

    Electrocardiographic characteristics can be useful in differentiating between right ventricular outflow tract (RVOT) and aortic sinus cusp (ASC) ventricular arrhythmias. Ventricular arrhythmias originating from ASC, however, show preferential conduction to RVOT that may render the algorithms of electrocardiographic characteristics less reliable. Even though there are few reports describing ventricular arrhythmias with ASC origins and endocardial breakout sites of RVOT, progressive dynamic changes in QRS morphology of the ventricular arrhythmias during ablation obtained were rare.This case report describes a patient with symptomatic premature ventricular contractions of left ASC origin presenting an electrocardiogram (ECG) characteristic of right ventricular outflow tract before ablation. Pacing at right ventricular outflow tract reproduced an excellent pace map. When radiofrequency catheter ablation was applied to the right ventricular outflow tract, the QRS morphology of premature ventricular contractions progressively changed from ECG characteristics of right ventricular outflow tract origin to ECG characteristics of left ASC origin.Successful radiofrequency catheter ablation was achieved at the site of the earliest ventricular activation in the left ASC. The distance between the successful ablation site of the left ASC and the site with an excellent pace map of the RVOT was 20 mm.The ndings could be strong evidence for a preferential conduction via the myocardial bers from the ASC origin to the breakout site in the right ventricular outflow tract. This case demonstrates that ventricular arrhythmias with a single origin and exit shift may exhibit QRS morphology changes.

  14. Analysis of QRS loop changes in the beat-to-beat Vectocardiogram of ischemic patients undergoing PTCA.

    PubMed

    Correa, Raul; Laciar, Eric; Arini, Pedro; Jane, Raimon

    2009-01-01

    In the present work, we have studied dynamic changes of QRS loop in the Vectocardiogram (VCG) of 80 patients that underwent Percutaneous Transluminal Coronary Angioplasty (PTCA). The VCG was obtained for each patient using the XYZ orthogonal leads of their electrocardiographic (ECG) records acquired before, during and after PTCA procedure. In order to analyze the variations of VCG, it has been proposed in this study the following parameters a) Maximum module of the cardiac depolarization vector, b) Volume, c) and Area of vectocardiographic loop corresponding to the QRS complex of each beat, d) Maximum distance between Centroid and the Loop, e) Angle between the XY plane and the Optimum Plane, f) Relation between the Area and Perimeter. The results obtained indicate that the parameters proposed show significant statistics differences (p-value<0.05) before, during (with some exceptions at the first minute of balloon inflation) and after PTCA. We conclude that the variations observed in the proposed parameters correctly represent not only the morphological changes in the depolarization VCG but also they reflect the modifications in the levels of cardiac ischemia induced by PTCA.

  15. A vector-free ECG interpretation with P, QRS & T waves as unbalanced transitions between stable configurations of the heart electric field during P-R, S-T & T-P segments

    PubMed Central

    2014-01-01

    duration than the QRS wave in the same lead. The proposed interpretation is applied to bundle branch blocks, fascicular (hemi-) blocks and changes during heart muscle ischemia. PMID:24506945

  16. Origins location of the outflow tract ventricular arrhythmias exhibiting qrS pattern or QS pattern with a notch on the descending limb in lead V1.

    PubMed

    Lin, Cong; Zheng, Cheng; Zhou, De-Pu; Li, Xiao-Wei; Wu, Shu-Jie; Lin, Jia-Feng

    2017-05-15

    Ventricular outflow tract(VOT) ventricular arrhythmias(VAs) presenting qrS pattern or QS pattern with a notch on the descending limb in lead V1 were consistently thought of arising from the commissure between left and right coronary cusp (L-RCC) by previous studies. However, we found they could originate from other anatomic structures in VOT. This study aimed to investigate the exact origin of this kind VAs. Forty-nine patients of VOT premature ventricular contrations/ventricular tachycardia(PVCs/VT) with lead V1 presenting qrS pattern or QS pattern with a notch on the descending limb undergoing successful radiofrequency catheter ablation(RFCA) in our center were analyzed. 12-lead electrocardiogram(ECG) of these PVCs/VT were summarized. Among these PVCs/VT, 37 cases exhibited qrS morphology in lead V1, 12 cases presented QS pattern with a notch on the descending limb in the same lead. Based on the successful ablation sites, these PVCs/VT were divided into 2 groups: (1)Right ventricular outflow tract(RVOT) group (26 cases), and (2) Left ventricular outflow tract (LVOT) group(23 cases, 4 cases originating from the left coronary cusp(LCC), 2 from the right coronary cusp(RCC), 16 from the L-RCC, 1 from the area inferior to LCC(ILCC)). The ECG characteristics of each PVCs/VT were analyzed. Among these PVCs/VT, applying the precordial transitional zone index(TZ index) < 0 to predict LVOT origin was demonstrated with sensitivity of 95.65%, specificity of 96.15%, positive predicting value(PPV) of 95.65% and negative predicting value(NPV) of 96.15%. In LVOT group, further applying the r, R, m,or Rs morphology in lead I to predict L-RCC and RCC origin was demonstrated with sensitivity of 94.44%, specificity of 60.00%, PPV of 89.47% and NPV of 75.00%. Ventricular outflow tract PVCs/VT with lead V1 presenting qrS pattern or QS pattern with a notch on descending limb not only arising from L-RCC, but also RVOT, LCC, RCC and ILCC. Combining TZ index and QRS morphology in lead I

  17. Signal averaging technique for noninvasive recording of late potentials in patients with coronary artery disease

    NASA Technical Reports Server (NTRS)

    Abboud, S.; Blatt, C. M.; Lown, B.; Graboys, T. B.; Sadeh, D.; Cohen, R. J.

    1987-01-01

    An advanced non invasive signal averaging technique was used to detect late potentials in two groups of patients: Group A (24 patients) with coronary artery disease (CAD) and without sustained ventricular tachycardia (VT) and Group B (8 patients) with CAD and sustained VT. Recorded analog data were digitized and aligned using a cross correlation function with fast Fourier transform schema, averaged and band pass filtered between 60 and 200 Hz with a non-recursive digital filter. Averaged filtered waveforms were analyzed by computer program for 3 parameters: (1) filtered QRS (fQRS) duration (2) interval between the peak of the R wave peak and the end of fQRS (R-LP) (3) RMS value of last 40 msec of fQRS (RMS). Significant change was found between Groups A and B in fQRS (101 -/+ 13 msec vs 123 -/+ 15 msec; p < .0005) and in R-LP vs 52 -/+ 11 msec vs 71-/+18 msec, p <.002). We conclude that (1) the use of a cross correlation triggering method and non-recursive digital filter enables a reliable recording of late potentials from the body surface; (2) fQRS and R-LP durations are sensitive indicators of CAD patients susceptible to VT.

  18. Combined assessment of myocardial damage and electrical disturbance in chronic heart failure

    PubMed Central

    Kadowaki, Shinpei; Watanabe, Tetsu; Otaki, Yoichiro; Narumi, Taro; Honda, Yuki; Takahashi, Hiroki; Arimoto, Takanori; Shishido, Tetsuro; Miyamoto, Takuya; Kubota, Isao

    2017-01-01

    AIM To investigate feasibility of combined assessment of biochemical and electrophysiological myocardial impairment markers risk-stratifying patients with chronic heart failure (CHF). METHODS Serum levels of heart-type fatty acid binding protein (H-FABP) as a marker of ongoing myocardial damage and QRS duration on electrocardiogram were measured at admission in 322 consecutive patients with CHF. A prolonged QRS duration was defined as 120 ms or longer. The cut-off value for H-FABP level (4.5 ng/mL) was determined from a previous study. Patients were prospectively followed during a median follow up period of 534 d. The primary endpoint was cardiac deaths and rehospitalization for worsening CHF. RESULTS There were 117 primary events, including 27 cardiac deaths and 90 rehospitalizations. Patients were stratified into four groups according to H-FABP level and QRS duration (≥ 120 ms). Multivariate analysis demonstrated that high H-FABP levels [hazard ratio (HR) = 1.745, P = 0.021] and QRS prolongation (HR 1.612, P = 0.0258) were independent predictors of cardiac events. Kaplan-Meier analysis demonstrated that the combination of high H-FABP levels and QRS prolongation could be used to reliably stratify patients at high risk for cardiac events (log rank test P < 0.0001). CONCLUSION Combined assessment of myocardial damage and electrical disturbance can be used to risk-stratify patients with CHF. PMID:28603594

  19. Value of the Electrocardiogram as a Predictor of Right Ventricular Dysfunction in Patients With Chronic Right Ventricular Volume Overload.

    PubMed

    Alonso, Pau; Andrés, Ana; Rueda, Joaquín; Buendía, Francisco; Igual, Begoña; Rodríguez, María; Osa, Ana; Arnau, Miguel A; Salvador, Antonio

    2015-05-01

    Pulmonary regurgitation is a common complication in patients with repaired tetralogy of Fallot or congenital pulmonary stenosis. Electrocardiographic variables have been correlated with parameters used to evaluate right ventricular function. We aimed to analyze the diagnostic value of the width and fragmentation of the electrocardiogram in the identification of patients with right ventricular dysfunction and/or dilation. We selected 107 consecutive patients diagnosed with severe pulmonary insufficiency after repair of pulmonary stenosis or tetralogy of Fallot. The tests included electrocardiography, echocardiography, and magnetic resonance. Each electrocardiogram was analyzed manually to measure QRS duration. We defined QRS fragmentation as the presence of low-voltage waves in the terminal portion of the QRS complex in at least 2 contiguous leads. We found a significant negative correlation between QRS width and right ventricular function, as well as a positive correlation with right ventricular volume. The receiver operating characteristic curve indicated a cut-off point for QRS width of 140ms, which showed good sensitivity for a diagnosis of right ventricular dilation (> 80%) and dysfunction (> 95%). In logistic regression models, a QRS duration > 140ms was found to be the only independent predictor of right ventricular dilation and dysfunction. Electrocardiography is a rapid, widely available, and reproducible tool. QRS width constitutes an independent predictor of the presence of right ventricular dilation and dysfunction. This study is the first to provide a cutoff value for QRS width to screen for right ventricle involvement. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  20. Design of a cardiac monitor in terms of parameters of QRS complex.

    PubMed

    Chen, Zhen-cheng; Ni, Li-li; Su, Ke-ping; Wang, Hong-yan; Jiang, Da-zong

    2002-08-01

    Objective. To design a portable cardiac monitor system based on the available ordinary ECG machine and works on the basis of QRS parameters. Method. The 80196 single chip microcomputer was used as the central microprocessor and real time electrocardiac signal was collected and analyzed [correction of analysized] in the system. Result. Apart from the performance of an ordinary monitor, this machine possesses also the following functions: arrhythmia analysis, HRV analysis, alarm, freeze, and record of automatic papering. Convenient in carrying, the system is powered by AC or DC sources. Stability, low power and low cost are emphasized in the hardware design; and modularization method is applied in software design. Conclusion. Popular in usage and low cost made the portable monitor system suitable for use under simple conditions.

  1. Electrocardiographic Impact of Myocardial Diffuse Fibrosis and Scar: MESA (Multi-Ethnic Study of Atherosclerosis)

    PubMed Central

    Inoue, Yuko Y.; Ambale-Venkatesh, Bharath; Mewton, Nathan; Volpe, Gustavo J.; Ohyama, Yoshiaki; Sharma, Ravi K.; Wu, Colin O.; Liu, Chia-Ying; Bluemke, David A.; Soliman, Elsayed Z.; Lima, João A. C.

    2017-01-01

    Purpose To examine the associations of myocardial diffuse fibrosis and scar with surface electrocardiographic (ECG) parameters in individuals free of prior coronary heart disease in four different ethnicities. Materials and Methods This prospective cross-sectional study was approved by the institutional review boards, and all participants gave informed consent. A total of 1669 participants in the Multi-Ethnic Study of Atherosclerosis, or MESA, who were free of prior myocardial infarction underwent both ECG and cardiac magnetic resonance imaging. In individuals without a late gadolinium enhancement–defined myocardial scar (n = 1131), T1 mapping was used to assess left ventricular (LV) interstitial diffuse fibrosis. The associations of LV diffuse fibrosis or myocardial scar with ECG parameters (QRS voltage, QRS duration, and corrected QT interval [QTc]) were evaluated by using multivariable regression analyses adjusted for demographic data, risk factors for scar, LV end-diastolic volume, and LV mass. Results The mean age of the 1669 participants was 67.4 years ± 8.7 (standard deviation); 49.8% were women. Lower postcontrast T1 time at 12 minutes was significantly associated with lower QRS Sokolow-Lyon voltage (β = 15.1 µV/10 msec, P = .004), lower QRS Cornell voltage (β = 9.2 µV/10 msec, P = .031), and shorter QRS duration (β = 0.16 msec/10 msec, P = .049). Greater extracellular volume (ECV) fraction was also significantly associated with lower QRS Sokolow-Lyon voltage (β = −35.2 µV/1% ECV increase, P < .001) and Cornell voltage (β = −23.7 µV/1% ECV increase, P < .001), independent of LV structural indexes. In contrast, the presence of LV scar (n = 106) was associated with longer QTc (β = 4.3 msec, P = .031). Conclusion In older adults without prior coronary heart disease, underlying greater LV diffuse fibrosis is associated with lower QRS voltage and shorter QRS duration at surface ECG, whereas clinically unrecognized myocardial scar is associated

  2. Where is the exact origin of narrow premature ventricular contractions manifesting qR in inferior wall leads?

    PubMed

    Zheng, Cheng; Li, Jin; Lin, Jia-Xuan; Wang, Lu-Ping; Lin, Jia-Feng

    2016-04-04

    In recent years, radiofrequency catheter ablation(RFCA) has been established as an effective therapy for idiopathic premature ventricular contractions (PVCs), however, its effect on the narrow PVCs (QRS duration < 130 msec) with qR pattern in inferior leads, may not been fully concluded. Characteristics of 12-lead electrocardiogram (ECG) and electrophysiologic recordings were analyzed in 40 patients with symptomatic PVCs manifesting narrow QRS complex with qR pattern in inferior leads. The procedure of RFCA was performed based on pace mapping and activation mapping. Among the 40 patients with narrow PVCs, complete elimination of PVCs was achieved by RFCA in 35 patients during a median follow-up period of 23 months. Successful ablation was achieved on 19 patients at the sites where earliest Purkinje potentials were recorded in left ventricular anterosuperior septum, thus PVCs arising from left anterior fascicle (LAF) were confirmed, for these PVCs, the QRS morphology were right bundle branch and left posterior fascicle block (RBBB + LPFB) with rightward axis, the average QRS duration 116.07 ± 7.96 ms, R or rsR'in lead V1,with transition zone ahead of lead V1 in precordial leads. Another 16 successful RFCA were achieved by energy delivery at interleaflet triangle(ILT) between right coronary cusp(RCC) and left coronary cusp(LCC) where no Purkinje potentials were recorded, for narrow PVCs arising from the L-RCC ILT, the QRS morphology were similar to the PVCs arising from LAF but much narrower in QRS duration (100.44 ± 3.49 vs. 116.07 ± 7.96 ms, p < 0.05), they were also R or Rs in lead V1 with the transition zone ahead of lead V1. For 5 symptomatic narrow PVCs failed to the procedure of RFCA, their electrocardiographic characteristics showed that the narrowest QRS duration (91.80 ± 6.94 vs. 100.44 ± 3.49, 116.07 ± 7.96 ms, p < 0.05), rs or rS (r/s or r/S≦1) morphology in lead V1 with the precordial transition zone behind lead V3. Most of idiopathic PVCs of

  3. Counterclockwise and Clockwise Rotation of QRS Transitional Zone: Prospective Correlates of Change and Time-Varying Associations With Cardiovascular Outcomes.

    PubMed

    Patel, Siddharth; Kwak, Lucia; Agarwal, Sunil K; Tereshchenko, Larisa G; Coresh, Josef; Soliman, Elsayed Z; Matsushita, Kunihiro

    2017-11-03

    A few studies have recently reported clockwise and counterclockwise rotations of QRS transition zone as predictors of mortality. However, their prospective correlates and associations with individual cardiovascular disease (CVD) outcomes are yet to be investigated. Among 13 567 ARIC (Atherosclerosis Risk in Communities) study participants aged 45 to 64 years, we studied key correlates of changes in the status of clockwise and counterclockwise rotation over time as well as the association of rotation status with incidence of coronary heart disease (2408 events), heart failure (2196 events), stroke (991 events), composite CVD (4124 events), 898 CVD deaths, and 3469 non-CVD deaths over 23 years of follow-up. At baseline, counterclockwise rotation was most prevalent (52.9%), followed by no (40.5%) and clockwise (6.6%) rotation. Of patients with no rotation, 57.9% experienced counterclockwise or clockwise rotation during follow-up, with diabetes mellitus and black race significantly predicting clockwise and counterclockwise conversion, respectively. Clockwise rotation was significantly associated with higher risk of heart failure (hazard ratio, 1.20; 95% confidence interval [CI], 1.02-1.41) and non-CVD death (hazard ratio, 1.28; 95% CI, 1.12-1.46) after adjusting for potential confounders including other ECG parameters. On the contrary, counterclockwise rotation was significantly related to lower risk of composite CVD (hazard ratio, 0.93; 95% CI, 0.87-0.99]), CVD mortality (hazard ratio, 0.76; 95% CI, 0.65-0.88), and non-CVD deaths (hazard ratio, 0.92; 95% CI, 0.85-0.99 [borderline significance with heart failure]). Counterclockwise rotation, the most prevalent QRS transition zone pattern, demonstrated the lowest risk of CVD and mortality, whereas clockwise rotation was associated with the highest risk of heart failure and non-CVD mortality. These results have implications on how to interpret QRS transition zone rotation when ECG was recorded. © 2017 The Authors

  4. A consensus algorithm for approximate string matching and its application to QRS complex detection

    NASA Astrophysics Data System (ADS)

    Alba, Alfonso; Mendez, Martin O.; Rubio-Rincon, Miguel E.; Arce-Santana, Edgar R.

    2016-08-01

    In this paper, a novel algorithm for approximate string matching (ASM) is proposed. The novelty resides in the fact that, unlike most other methods, the proposed algorithm is not based on the Hamming or Levenshtein distances, but instead computes a score for each symbol in the search text based on a consensus measure. Those symbols with sufficiently high scores will likely correspond to approximate instances of the pattern string. To demonstrate the usefulness of the proposed method, it has been applied to the detection of QRS complexes in electrocardiographic signals with competitive results when compared against the classic Pan-Tompkins (PT) algorithm. The proposed method outperformed PT in 72% of the test cases, with no extra computational cost.

  5. Patients with left bundle branch block and left axis deviation show a specific left ventricular asynchrony pattern: Implications for left ventricular lead placement during CRT implantation.

    PubMed

    Sciarra, Luigi; Golia, Paolo; Palamà, Zefferino; Scarà, Antonio; De Ruvo, Ermenegildo; Borrelli, Alessio; Martino, Anna Maria; Minati, Monia; Fagagnini, Alessandro; Tota, Claudia; De Luca, Lucia; Grieco, Domenico; Delise, Pietro; Calò, Leonardo

    Left bundle branch block (LBBB) and left axis deviation (LAD) patients may have poor response to resynchronization therapy (CRT). We sought to assess if LBBB and LAD patients show a specific pattern of mechanical asynchrony. CRT candidates with non-ischemic cardiomyopathy and LBBB were categorized as having normal QRS axis (within -30° and +90°) or LAD (within -30° and -90°). Patients underwent tissue Doppler imaging (TDI) to measure time interval between onset of QRS complex and peak systolic velocity in ejection period (Q-peak) at basal segments of septal, inferior, lateral and anterior walls, as expression of local timing of mechanical activation. Thirty patients (mean age 70.6years; 19 males) were included. Mean left ventricular ejection fraction was 0.28±0.06. Mean QRS duration was 172.5±13.9ms. Fifteen patients showed LBBB with LAD (QRS duration 173±14; EF 0.27±0.06). The other 15 patients had LBBB with a normal QRS axis (QRS duration 172±14; EF 0.29±0.05). Among patients with LAD, Q-peak interval was significantly longer at the anterior wall in comparison to each other walls (septal 201±46ms, inferior 242±58ms, lateral 267±45ms, anterior 302±50ms; p<0.0001). Conversely, in patients without LAD Q-peak interval was longer at lateral wall, when compared to each other (septal 228±65ms, inferior 250±64ms, lateral 328±98ms, anterior 291±86ms; p<0.0001). Patients with heart failure, presenting LBBB and LAD, show a specific pattern of ventricular asynchrony, with latest activation at anterior wall. This finding could affect target vessel selection during CRT procedures in these patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Evaluation of mechanical dyssynchrony and myocardial perfusion using phase analysis of gated SPECT imaging in patients with left ventricular dysfunction

    PubMed Central

    Trimble, Mark A.; Borges-Neto, Salvador; Honeycutt, Emily F.; Shaw, Linda K.; Pagnanelli, Robert; Chen, Ji; Iskandrian, Ami E.; Garcia, Ernest V.; Velazquez, Eric J.

    2010-01-01

    Background Using phase analysis of gated single photon emission computed tomography (SPECT) imaging, we examined the relation between myocardial perfusion, degree of electrical dyssynchrony, and degree of SPECT-derived mechanical dyssynchrony in patients with left ventricular (LV) dysfunction. Methods and Results We retrospectively examined 125 patients with LV dysfunction and ejection fraction of 35% or lower. Fourier analysis converts regional myocardial counts into a continuous thickening function, allowing resolution of phase of onset of myocardial thickening. The SD of LV phase distribution (phase SD) and histogram bandwidth describe LV phase dispersion as a measure of dyssynchrony. Heart failure (HF) patients with perfusion abnormalities ities have higher degrees of dyssynchrony measured by median phase SD (45.5° vs 27.7°, P < .0001) and bandwidth (117.0° vs 73.0°, P = .0006). HF patients with prolonged QRS durations have higher degrees of dyssynchrony measured by median phase SD (54.1° vs 34.7°, P < .0001) and bandwidth (136.5° vs 99.0°, P = .0005). Mild to moderate correlations exist between QRS duration and phase analysis indices of phase SD (r = 0.50) and bandwidth (r = 0.40). Mechanical dyssynchrony (phase SD >43°) was 43.2%. Conclusions HF patients with perfusion abnormalities or prolonged QRS durations QRS durations have higher degrees of mechanical dyssynchrony. Gated SPECT myocardial perfusion imaging can quantify myocardial function, perfusion, and dyssynchrony and may help in evaluating patients for cardiac resynchronization therapy. PMID:18761269

  7. Time frequency power profile of QRS complex obtained with wavelet transform in spontaneously hypertensive rats.

    PubMed

    Takano, Nami K; Tsutsumi, Takeshi; Suzuki, Hiroshi; Okamoto, Yoshiwo; Nakajima, Toshiaki

    2012-02-01

    We evaluated whether frequency analysis could detect the development of interstitial fibrosis in rats. SHR/Izm and age-matched WKY/Izm were used. Limb lead II electrocardiograms were recorded. Continuous wavelet transform (CWT) was applied for the time-frequency analysis. The integrated time-frequency power (ITFP) between QRS complexes was measured and compared between groups. The ITFP at low-frequency bands (≤125Hz) was significantly higher in SHR/Izm. The percent change of ITFP showed the different patterns between groups. Prominent interstitial fibrosis with an increase in TIMP-1 mRNA expression was also observed in SHR/Izm. These results were partly reproduced in a computer simulation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Effect of study design on the reported effect of cardiac resynchronization therapy (CRT) on quantitative physiological measures: stratified meta-analysis in narrow-QRS heart failure and implications for planning future studies.

    PubMed

    Jabbour, Richard J; Shun-Shin, Matthew J; Finegold, Judith A; Afzal Sohaib, S M; Cook, Christopher; Nijjer, Sukhjinder S; Whinnett, Zachary I; Manisty, Charlotte H; Brugada, Josep; Francis, Darrel P

    2015-01-06

    Biventricular pacing (CRT) shows clear benefits in heart failure with wide QRS, but results in narrow QRS have appeared conflicting. We tested the hypothesis that study design might have influenced findings. We identified all reports of CRT-P/D therapy in subjects with narrow QRS reporting effects on continuous physiological variables. Twelve studies (2074 patients) met these criteria. Studies were stratified by presence of bias-resistance steps: the presence of a randomized control arm over a single arm, and blinded outcome measurement. Change in each endpoint was quantified using a standardized effect size (Cohen's d). We conducted separate meta-analyses for each variable in turn, stratified by trial quality. In non-randomized, non-blinded studies, the majority of variables (10 of 12, 83%) showed significant improvement, ranging from a standardized mean effect size of +1.57 (95%CI +0.43 to +2.7) for ejection fraction to +2.87 (+1.78 to +3.95) for NYHA class. In the randomized, non-blinded study, only 3 out of 6 variables (50%) showed improvement. For the randomized blinded studies, 0 out of 9 variables (0%) showed benefit, ranging from -0.04 (-0.31 to +0.22) for ejection fraction to -0.1 (-0.73 to +0.53) for 6-minute walk test. Differences in degrees of resistance to bias, rather than choice of endpoint, explain the variation between studies of CRT in narrow-QRS heart failure addressing physiological variables. When bias-resistance features are implemented, it becomes clear that these patients do not improve in any tested physiological variable. Guidance from studies without careful planning to resist bias may be far less useful than commonly perceived. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  9. The role of electrocardiography in evaluation of severity of chronic obstructive pulmonary disease in daily clinical practice.

    PubMed

    Aktürk, Faruk; Bıyık, İsmail; Kocaş, Cüneyt; Ertürk, Mehmet; Yalçın, Ahmet Arif; Savaş, Ayfer Utku; Kuzer, Firuzan Pınar; Uzun, Fatih; Yıldırım, Aydın; Uslu, Nevzat; Çuhadaroğlu, Çağlar

    2013-01-01

    Chronic obstructive pulmonary disease (COPD) is the fourth leading cause of chronic morbidity and mortality. Bronchial obstruction and increased pulmonary vascular resistance impairs right atrial functions. In this study, we aimed to investigate the effect of bronchial obstruction on p wave axis in patients with COPD and usefulness of electrocardiography (ECG) in the evaluation of the severity of COPD. Ninety five patients (64 male and 31 female) included to the study. Patients were in sinus rhythm, with normal ejection fraction and heart chamber sizes. Their respiratory function tests and 12 lead electrocardiograms were obtained at same day. Correlations with severity of COPD and ECG findings including p wave axis, p wave duration, QRS axis, QRS duration were studied. The mean age was 58 ± 12 years. Their mean p wave axis was 62 ± 18 degrees. In this study, p wave axis has demonstrated significant positive correlations with stages of COPD and QRS axis but significant negative correlations with FEV1, FEF, BMI and QRS duration. P wave axis increases with increasing stages of COPD. Verticalization of the frontal p wave axis may be an early finding of worsening of COPD before occurrences of other ECG changes of hypertrophy and enlargement of right heart chambers such as p pulmonale. Verticalization of the frontal p wave axis reflecting right atrial electrical activity and right heart strain may be a useful parameter for quick estimation of the severity of COPD in an out-patient cared.

  10. Signal-Averaged Electrocardiogram in Physically Healthy, Chronic 3,4-Methylenedioxymethamphetamine (MDMA) Users

    PubMed Central

    Kanneganti, Praveen; Huestis, Marilyn A.; Kolbrich, Erin A.; Robert, Goodwin; Ziegelstein, Roy C.; Gorelick, David A.

    2008-01-01

    Objectives 3,4-Methylenedioxymethamphetamine (MDMA, ecstasy) use has been associated with cardiac arrhythmias. Markers of ventricular late potentials (VLP), which may be a precursor to malignant ventricular arrhythmias, can be detected by signal-averaged electrocardiography (SA-ECG), but not by standard ECG. Methods We evaluated SA-ECG parameters in 21 physically healthy, recently abstinent MDMA users who also used cannabis (11 males, mean [SD] age 23.3 [4.6] years, 2.8 [2.0] years of use), 18 physically healthy cannabis users (8 males, mean [SD] age 26.6 [7.1] years, 11.2 [5.4] years of use) and 54 non-drug-using controls (21 males, mean [SD] age 28.4 [7.8] years). We analyzed three SA-ECG parameters considered markers of VLPs: duration of filtered QRS complex (fQRS), duration of low amplitude potentials during terminal 40 ms of QRS complex (LAS40), and root mean square voltage during terminal 40 ms of QRS complex (RMS40). Results MDMA users, cannabis users, and non-drug-using controls did not differ significantly from each other in fQRS, LAS40, or RMS40 values or in the proportion of subjects with abnormal SA-ECG parameters. There were significant gender differences among controls, but not among MDMA users. Conclusion These findings suggest that chronic MDMA use is neither quantitatively nor qualitatively associated with a high prevalence of abnormal SA-ECG parameters indicative of VLP markers. PMID:18855243

  11. Cardiac pacemaker battery discharge after external electrical cardioversion for broad QRS Complex Tachycardia.

    PubMed

    Annamaria, Martino; Andrea, Scapigliati; Michela, Casella; Tommaso, Sanna; Gemma, Pelargonio; Antonio, Dello Russo; Roberto, Zamparelli; Stefano, De Paulis; Fulvio, Bellocci; Rocco, Schiavello

    2008-08-01

    External electrical cardioversion or defibrillation may be necessary in patients with implanted cardiac pacemaker (PM) or implantable cardioverter defibrillator (ICD). Sudden discharge of high electrical energy employed in direct current (DC) transthoracic countershock may damage the PM/ICD system resulting in a series of possible device malfunctions. For this reason, when defibrillation or cardioversion must be attempted in a patient with a PM or ICD, some precautions should be taken, particularly in PM dependent patients, in order to prevent damage to the device. We report the case of a 76-year-old woman with a dual chamber PM implanted in the right subclavicular region, who received two consecutive transthoracic DC shocks to treat haemodynamically unstable broad QRS complex tachycardia after cardiac surgery performed with a standard sternotomic approach. Because of the sternal wound and thoracic drainage tubes together with the severe clinical compromise, the anterior paddle was positioned near the pulse generator. At the following PM test, a complete battery discharge was detected.

  12. The impact of trans-catheter aortic valve replacement induced left-bundle branch block on cardiac reverse remodeling.

    PubMed

    Dobson, Laura E; Musa, Tarique A; Uddin, Akhlaque; Fairbairn, Timothy A; Bebb, Owen J; Swoboda, Peter P; Haaf, Philip; Foley, James; Garg, Pankaj; Fent, Graham J; Malkin, Christopher J; Blackman, Daniel J; Plein, Sven; Greenwood, John P

    2017-02-22

    Left bundle branch block (LBBB) is common following trans-catheter aortic valve replacement (TAVR) and has been linked to increased mortality, although whether this is related to less favourable cardiac reverse remodeling is unclear. The aim of the study was to investigate the impact of TAVR induced LBBB on cardiac reverse remodeling. 48 patients undergoing TAVR for severe aortic stenosis were evaluated. 24 patients with new LBBB (LBBB-T) following TAVR were matched with 24 patients with a narrow post-procedure QRS (nQRS). Patients underwent cardiovascular magnetic resonance (CMR) prior to and 6 m post-TAVR. Measured cardiac reverse remodeling parameters included left ventricular (LV) size, ejection fraction (LVEF) and global longitudinal strain (GLS). Inter- and intra-ventricular dyssynchrony were determined using time to peak radial strain derived from CMR Feature Tracking. In the LBBB-T group there was an increase in QRS duration from 96 ± 14 to 151 ± 12 ms (P < 0.001) leading to inter- and intra-ventricular dyssynchrony (inter: LBBB-T 130 ± 73 vs nQRS 23 ± 86 ms, p < 0.001; intra: LBBB-T 118 ± 103 vs. nQRS 13 ± 106 ms, p = 0.001). Change in indexed LV end-systolic volume (LVESVi), LVEF and GLS was significantly different between the two groups (LVESVi: nQRS -7.9 ± 14.0 vs. LBBB-T -0.6 ± 10.2 ml/m 2 , p = 0.02, LVEF: nQRS +4.6 ± 7.8 vs LBBB-T -2.1 ± 6.9%, p = 0.002; GLS: nQRS -2.1 ± 3.6 vs. LBBB-T +0.2 ± 3.2%, p = 0.024). There was a significant correlation between change in QRS and change in LVEF (r = -0.434, p = 0.002) and between change in QRS and change in GLS (r = 0.462, p = 0.001). Post-procedure QRS duration was an independent predictor of change in LVEF and GLS at 6 months. TAVR-induced LBBB is associated with less favourable cardiac reverse remodeling at medium term follow up. In view of this, every effort should be made to prevent TAVR-induced LBBB

  13. The energy-efficient implementation of an adaptive-filtering-based QRS complex detection method for wearable devices

    NASA Astrophysics Data System (ADS)

    Tian, Shudong; Han, Jun; Yang, Jianwei; Zeng, Xiaoyang

    2017-10-01

    Electrocardiogram (ECG) can be used as a valid way for diagnosing heart disease. To fulfill ECG processing in wearable devices by reducing computation complexity and hardware cost, two kinds of adaptive filters are designed to perform QRS complex detection and motion artifacts removal, respectively. The proposed design achieves a sensitivity of 99.49% and a positive predictivity of 99.72%, tested under the MIT-BIH ECG database. The proposed design is synthesized under the SMIC 65-nm CMOS technology and verified by post-synthesis simulation. Experimental results show that the power consumption and area cost of this design are of 160 μW and 1.09 × 10 5 μm2, respectively. Project supported by the National Natural Science Foundation of China (Nos. 61574040, 61234002, 61525401).

  14. Screening of young competitive athletes for the prevention of sudden cardiac death with a wireless electrocardiographic transmission device: a pilot study.

    PubMed

    Cho, Jae Hyung; Selen, Mats A; Kocheril, Abraham G

    2015-08-11

    The 12-lead electrocardiographic screening for the prevention of sudden cardiac death in young competitive athletes is not cost-effective and thus not routinely recommended. We investigate whether a less expensive wireless electrocardiographic transmission device can be used to screen for the prevention of sudden cardiac death in this population. During pre-participation screening, twenty college football players underwent two electrocardiograms: a conventional 12-lead electrocardiogram and a wireless 9-lead electrocardiogram. We compared several electrocardiographic parameters (QRS duration, left ventricular hypertrophy using the Cornell voltage criteria and the Sokolow-Lyon criteria, ST deviation and corrected QT interval) to determine the correlation. The QRS duration, left ventricular hypertrophy using the Cornell voltage criteria and the Sokolow-Lyon criteria and corrected QT interval exhibited significant correlation between the two types of electrocardiograms (correlation coefficient 0.878, 0.630, 0.770 and 0.847, respectively with P values of 0.01, 0.003, 0.01 and 0.01, respectively). ST deviation in V1 was weakly correlated between the two types of electrocardiograms without statistical significance (correlation coefficient 0.360 with a P value of 0.119). Our newly developed wireless 9-lead electrocardiogram demonstrated significant correlations with a conventional 12-lead electrocardiogram in terms of QRS duration, left ventricular hypertrophy and corrected QT interval.

  15. Validation of criteria for selective his bundle and para-hisian permanent pacing.

    PubMed

    Cantù, F; De Filippo, P; Cardano, P; De Luca, A; Gavazzi, A

    2006-12-01

    His Bundle (HB) pacing is a valid alternative to right ventricular pacing for patients with preserved His-ventricle conduction who are candidates for permanent stimulation. Permanent pacing in the HB area enables Selective HB pacing (SHBP) or para-Hisian pacing (PHP) to be achieved. The aim of our study was to draw up a set of easy criteria to differentiate and validate the two kinds of stimulations according to the pacing output and the ECG/EKG signals. From February to July 2005, 17 patients eligible for a pacemaker (PM) procedure underwent implantation with the Medtronic SelectSecure lead (Medtronic, Minneapolis, MN, USA) screwed into the HB area.SHBP was defined when the intrinsic QRS was equal, in both duration and morphology, to the paced QRS, the His-Ventricular (H-V) interval was equal to Pace-Ventricular interval (Vp-V) and, at low output, only the HB was captured, while increasing the output resulted in both the HB and right ventricular (RV) being captured (widening of QRS at high output). Conversely, PHP was defined when the intrinsic QRS differed from the paced one, either in morphology or in duration and, at high output, both the RV and HB were captured (non-SHBP), while decreasing the output resulted in losing HB capture (widening of QRS at low output). According to these criteria, SHBP was achieved in 11 patients, while in the remaining 6, PHP was obtained. No adverse events were reported. The above criteria enabled SHBP and PHP to be validated easily and clearly. A longer follow-up will be needed in order to ascertain whether the clinical outcome of these two approaches differs.

  16. Value of the Electrocardiographic (P Wave, T Wave, QRS) Axis as a Predictor of Mortality in 14 Years in a Population With a High Prevalence of Chagas Disease from the Bambuí Cohort Study of Aging.

    PubMed

    Moraes, Diego N; Nascimento, Bruno R; Beaton, Andrea Z; Soliman, Elsayed Z; Lima-Costa, Maria Fernanda; Dos Reis, Rodrigo C P; Ribeiro, Antonio Luiz P

    2018-02-01

    We sought to investigate the prognostic value of the electrocardiogram (ECG) electrical axes (P wave, T wave and QRS) as predictors of mortality in the 14-year follow-up of the prospective cohort of all residents ≥60 years living in the southeastern Brazilian city of Bambuí, a population with high prevalence of Chagas disease (ChD). Baseline ECG axes were automatically measured with normal values defined as follows: P-wave axis 0° to 75°, QRS axis -30° to 90°, and T axis 15° to 75°. Participants underwent annual follow-up visits and death was verified using death certificates. Cox proportional hazards regression was used to assess the prognostic value of ECG axes for all-cause mortality, after adjustment for potential confounders. From 1,742 qualifying residents, 1,462 were enrolled, of whom 557 (38.1%) had ChD. Mortality rate was 51.9%. In multivariable adjusted models, abnormal P-wave axis was associated with a 48% (hazard ratio [HR] = 1.48 [95% confidence interval (CI) 1.16-1.88]) increased mortality risk in patients with ChD and 43% (HR = 1.43 [CI 1.13-1.81]) in patients without ChD. Abnormal QRS axis was associated with a 34% (HR = 1.34 [CI 1.04-1.73]) increased mortality risk in patients with ChD, but not in individuals without ChD. Similarly, in the ChD group, abnormal T-wave axis was associated with a 35% (HR = 1.35 [CI 1.07-1.71]) increased mortality, but not in patients without ChD. In conclusion, abnormal P-wave, QRS, and T-wave axes were associated with increased all-cause mortality in patients with ChD. Abnormal P-wave axis was associated with mortality also among those without ChD, being the strongest predictor among ECG variables. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Mechanical Dyssynchrony Precedes QRS Widening in ATP‐Sensitive K+ Channel–Deficient Dilated Cardiomyopathy

    PubMed Central

    Yamada, Satsuki; Arrell, D. Kent; Kane, Garvan C.; Nelson, Timothy J.; Perez‐Terzic, Carmen M.; Behfar, Atta; Purushothaman, Saranya; Prinzen, Frits W.; Auricchio, Angelo; Terzic, Andre

    2013-01-01

    Background Contractile discordance exacerbates cardiac dysfunction, aggravating heart failure outcome. Dissecting the genesis of mechanical dyssynchrony would enable an early diagnosis before advanced disease. Methods and Results High‐resolution speckle‐tracking echocardiography was applied in a knockout murine surrogate of adult‐onset human cardiomyopathy caused by mutations in cardioprotective ATP‐sensitive K+ (KATP) channels. Preceding the established criteria of cardiac dyssynchrony, multiparametric speckle‐based strain resolved nascent erosion of dysfunctional regions within cardiomyopathic ventricles of the KATP channel–null mutant exposed to hemodynamic stress. Not observed in wild‐type counterparts, intraventricular disparity in wall motion, validated by the degree, direction, and delay of myocardial speckle patterns, unmasked the disease substrate from asymptomatic to overt heart failure. Mechanical dyssynchrony preceded widening of the QRS complex and exercise intolerance and progressed into global myocardial discoordination and decompensated cardiac pump function, precipitating a low output syndrome. Conclusions The present study, with the use of high‐resolution imaging, prospectively resolved the origin and extent of intraventricular motion disparity in a KATP channel–knockout model of dilated cardiomyopathy. Mechanical dyssynchrony established as an early marker of cardiomyopathic disease offers novel insight into the pathodynamics of dyssynchronous heart failure. PMID:24308936

  18. Canine left ventricle electromechanical behavior under different pacing modes.

    PubMed

    Vo Thang, Thanh-Thuy; Thibault, Bernard; Finnerty, Vincent; Pelletier-Galarneau, Matthieu; Khairy, Paul; Grégoire, Jean; Harel, François

    2012-10-01

    Cardiac resynchronization therapy may improve survival and quality of life in patients suffering from heart failure with left ventricular (LV) contraction dyssynchrony. While several studies have investigated electrical or mechanical determinants of synchronous contraction, few have focused on activation contraction coupling at a macroscopic level. The objective of the study was to characterize LV electromechanical behavior and response to pacing in a heart failure model. We analyzed data from 3D electroanatomic non-contact mapping and blood pool SPECT for 12 dogs with right ventricular (RV) tachycardia pacing-induced dilated cardiomyopathy. Surfaces generated by the two modalities were registered. Electrical signals were analyzed, and endocardial wall displacement curves were portrayed. Rapid pacing decreased the mean LV ejection fraction (LVEF) to 20.9 % and prolonged the QRS duration to 79 ± 10 ms (normal range: 40-50 ms). QRS duration remained unchanged with biventricular pacing (88.5 ms), while single site pacing further prolonged the QRS duration (113.3 ms for RV pacing and 111.6 ms for LV pacing). No trend was observed in LV systolic function. Activation duration time was significantly increased with all pacing modes compared to baseline. Finally, electromechanical delay, as defined by the delay between electrical activation and mechanical response, was increased by single site pacing (172.9 ms for RV pacing and 174.6 ms for LV pacing) but not by biventricular pacing (162.4 ms). Combined temporal and spatial coregistration electroanatomic maps and baseline gated blood pool SPECT imaging allowed us to quantify activation duration time, electromechanical delay, and LVEF for different pacing modes. Even if pacing modes did not significantly modify LVEF or activation duration, they produced alterations in electromechanical delay, with biventricular pacing significantly decreasing the electromechanical delay as measured by surface tracings and endocardial

  19. The spatial QRS-T angle in the Frank vectorcardiogram: accuracy of estimates derived from the 12-lead electrocardiogram.

    PubMed

    Schreurs, Charlotte A; Algra, Annemijn M; Man, Sum-Che; Cannegieter, Suzanne C; van der Wall, Ernst E; Schalij, Martin J; Kors, Jan A; Swenne, Cees A

    2010-01-01

    The spatial QRS-T angle (SA), a predictor of sudden cardiac death, is a vectorcardiographic variable. Gold standard vertorcardiograms (VCGs) are recorded by using the Frank electrode positions. However, with the commonly available 12-lead ECG, VCGs must be synthesized by matrix multiplication (inverse Dower matrix/Kors matrix). Alternatively, Rautaharju proposed a method to calculate SA directly from the 12-lead ECG. Neither spatial angles computed by using the inverse Dower matrix (SA-D) nor by using the Kors matrix (SA-K) or by using Rautaharju's method (SA-R) have been validated with regard to the spatial angles as directly measured in the Frank VCG (SA-F). Our present study aimed to perform this essential validation. We analyzed SAs in 1220 simultaneously recorded 12-lead ECGs and VCGs, in all data, in SA-F-based tertiles, and after stratification according to pathology or sex. Linear regression of SA-K, SA-D, and SA-R on SA-F yielded offsets of 0.01 degree, 20.3 degrees, and 28.3 degrees and slopes of 0.96, 0.86, and 0.79, respectively. The bias of SA-K with respect to SA-F (mean +/- SD, -3.2 degrees +/- 13.9 degrees) was significantly (P < .001) smaller than the bias of both SA-D and SA-R with respect to SA-F (8.0 degrees +/- 18.6 degrees and 9.8 degrees +/- 24.6 degrees, respectively); tertile analysis showed a much more homogeneous behavior of the bias in SA-K than of both the bias in SA-D and in SA-R. In pathologic ECGs, there was no significant bias in SA-K; bias in men and women did not differ. SA-K resembled SA-F best. In general, when there is no specific reason either to synthesize VCGs with the inverse Dower matrix or to calculate the spatial QRS-T angle with Rautaharju's method, it seems prudent to use the Kors matrix. Copyright 2010 Elsevier Inc. All rights reserved.

  20. Sleep Detriments Associated With Quick Returns in Rotating Shift Work: A Diary Study.

    PubMed

    Vedaa, Øystein; Mørland, Erik; Larsen, Marit; Harris, Anette; Erevik, Eilin; Sivertsen, Børge; Bjorvatn, Bjørn; Waage, Siri; Pallesen, Ståle

    2017-06-01

    We aimed to compared sleep characteristics associated with quick returns (QRs, <11 hours between shift intervals) with those associated with other common shift transitions. Sixty-seven nurses completed a 2-week work and sleep diary (94.0% female, mean age 47.7 years). A multilevel fixed effects model was used to examine the sleep in QRs compared with two consecutive night shifts, two consecutive evening shifts, and two consecutive day shifts, respectively. None of the other shift transitions studied encumbered as many detriments as QRs, which included short sleep duration (5.6 hours), slightly prolonged sleep onset latency, more abrupt ending of main sleep period, increased sleepiness, and higher level of perceived stress on the following shift. The study emphasizes the need for sufficient time for rest and recuperation between shifts.

  1. Ventricular Tachycardia or not? An Unexpected Reason of Wide QRS Complex Tachycardia in a Young Healthy Man: Sodium Bicarbonate.

    PubMed

    Eyuboglu, Mehmet

    2016-10-01

    Ventricular tachycardia (VT) is life-threatening subgroup of wide QRS complex tachycardia (WCT). VT is usually associated with structural heart diseases, but it can occur in the absence of any cardiovascular diseases. Adverse cardiac effect of sodium bicarbonate in healthy subjects is not well described. A 30-year-old healthy man with excessive intake of sodium bicarbonate-related VT is presented. He was using sodium bicarbonate during last 2 months to lose weight. He has no risk factors and any cardiovascular or systemic diseases. After intravenous administration of amiodarone, tachycardia ended and his rhythm converted to sinus rhythm with normal electrocardiogram. Patient is asymptomatic, and no VT was observed without any medications at 1 year of follow-up.

  2. Incorrect electrode cable connection during electrocardiographic recording.

    PubMed

    Batchvarov, Velislav N; Malik, Marek; Camm, A John

    2007-11-01

    Incorrect electrode cable connections during electrocardiographic (ECG) recording can simulate rhythm or conduction disturbance, myocardial ischaemia and infarction, as well as other clinically important abnormalities. When only precordial or only limb cables, excluding the neutral cable, have been interchanged the waveforms in the different leads are re-arranged, inverted, or unchanged, whereas the duration of intervals is not changed. The mistake can be recognized by the presence of unusual P-QRS patterns (e.g. negative P-QRS in lead I or II, positive in lead AVR, P-QRS complexes of opposite direction in leads I and V6, etc.), change in the P-QRS axis, or abnormal precordial QRS-T wave progression. Interchange of limb cables with the neutral cable distorts Wilson's terminal and the morphology of all precordial and unipolar limb leads. The telltale sign of the mistake is the presence of (almost) a flat line in lead I, II or III. Interchange of even one of the limb cables, except for the neutral cable, with a precordial cable distorts the morphology of most leads and leaves not more than one lead (I, II, or III) unchanged. Computerized algorithms for detection of lead misplacement, such as those based on artificial neural networks, or on correlation between original and reconstructed leads, have been developed.

  3. Association of Age, Sex, Body Size and Ethnicity with Electrocardiographic Values in Community-based Older Asian Adults.

    PubMed

    Tan, Eugene S J; Yap, Jonathan; Xu, Chang Fen; Feng, Liang; Nyunt, Shwe Zin; Santhanakrishnan, Rajalakshmi; Chan, Michelle M Y; Seow, Swee Chong; Ching, Chi Keong; Yeo, Khung Keong; Richards, A Mark; Ng, Tze Pin; Lim, Toon Wei; Lam, Carolyn S P

    2016-07-01

    Existing electrocardiographic (ECG) reference values were derived in middle-aged Caucasian adults. We aimed to assess the association of age, sex, body size and ethnicity on ECG parameters in a multi-ethnic Asian population. Resting 12-lead ECG and anthropometric measurements were performed in a community-based cohort of 3777 older Asians (age 64.7±9.1 years, 1467 men, 88.8% Chinese, 7.7% Malay, 3.5% Indian, body mass index [BMI] 24.0±3.9kg/m(2)). Men had longer PR interval, wider QRS, shorter QTc interval and taller SV3. In both sexes, older age was associated with longer PR interval, wider QRS, larger R aVL and more leftward QRS axis, while higher BMI was associated with longer PR interval, wider QRS, larger RaVL and more negative QRS axis. There were significant inter-ethnic differences in QRS duration among men, as well as in PR and QTc intervals among women (all adjusted p<0.05). Findings were similar in a healthy subset of 1158 adults (age 61.2±9.1 years, 365 men) without cardiovascular risk factors. These first community-based ECG data in multi-ethnic older Asians highlight the independent effects of age, sex, body size and ethnicity on ECG parameters. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  4. Effect of gender on computerized electrocardiogram measurements in college athletes.

    PubMed

    Mandic, Sandra; Fonda, Holly; Dewey, Frederick; Le, Vy-van; Stein, Ricardo; Wheeler, Matt; Ashley, Euan A; Myers, Jonathan; Froelicher, Victor F

    2010-06-01

    Broad criteria for classifying an electrocardiogram (ECG) as abnormal and requiring additional testing prior to participating in competitive athletics have been recommended for the preparticipation examination (PPE) of athletes. Because these criteria have not considered gender differences, we examined the effect of gender on the computerized ECG measurements obtained on Stanford student athletes. Currently available computer programs require a basis for "normal" in athletes of both genders to provide reliable interpretation. During the 2007 PPE, computerized ECGs were recorded and analyzed on 658 athletes (54% male; mean age, 19 +/- 1 years) representing 22 sports. Electrocardiogram measurements included intervals and durations in all 12 leads to calculate 12-lead voltage sums, QRS amplitude and QRS area, spatial vector length (SVL), and the sum of the R wave in V5 and S wave in V2 (RSsum). By computer analysis, male athletes had significantly greater QRS duration, PR interval, Q-wave duration, J-point amplitude, and T-wave amplitude, and shorter QTc interval compared with female athletes (all P < 0.05). All ECG indicators of left ventricular electrical activity were significantly greater in males. Although gender was consistently associated with indices of atrial and ventricular electrical activity in multivariable analysis, ECG measurements correlated poorly with body dimensions. Significant gender differences exist in ECG measurements of college athletes that are not explained by differences in body size. Our tables of "normal" computerized gender-specific measurements can facilitate the development of automated ECG interpretation for screening young athletes.

  5. 52 Genetic Loci Influencing Myocardial Mass

    PubMed Central

    van der Harst, Pim; van Setten, Jessica; Verweij, Niek; Vogler, Georg; Franke, Lude; Maurano, Matthew T.; Wang, Xinchen; Leach, Irene Mateo; Eijgelsheim, Mark; Sotoodehnia, Nona; Hayward, Caroline; Sorice, Rossella; Meirelles, Osorio; Lyytikäinen, Leo-Pekka; Polašek, Ozren; Tanaka, Toshiko; Arking, Dan E.; Ulivi, Sheila; Trompet, Stella; Müller-Nurasyid, Martina; Smith, Albert V.; Dörr, Marcus; Kerr, Kathleen F.; Magnani, Jared W.; Fabiola Del Greco, M.; Zhang, Weihua; Nolte, Ilja M.; Silva, Claudia T.; Padmanabhan, Sandosh; Tragante, Vinicius; Esko, Tõnu; Abecasis, Gonçalo R.; Adriaens, Michiel E.; Andersen, Karl; Barnett, Phil; Bis, Joshua C.; Bodmer, Rolf; Buckley, Brendan M.; Campbell, Harry; Cannon, Megan V.; Chakravarti, Aravinda; Chen, Lin Y.; Delitala, Alessandro; Devereux, Richard B.; Doevendans, Pieter A.; Dominiczak, Anna F.; Ferrucci, Luigi; Ford, Ian; Gieger, Christian; Harris, Tamara B.; Haugen, Eric; Heinig, Matthias; Hernandez, Dena G.; Hillege, Hans L.; Hirschhorn, Joel N.; Hofman, Albert; Hubner, Norbert; Hwang, Shih-Jen; Iorio, Annamaria; Kähönen, Mika; Kellis, Manolis; Kolcic, Ivana; Kooner, Ishminder K.; Kooner, Jaspal S.; Kors, Jan A.; Lakatta, Edward G.; Lage, Kasper; Launer, Lenore J.; Levy, Daniel; Lundby, Alicia; Macfarlane, Peter W.; May, Dalit; Meitinger, Thomas; Metspalu, Andres; Nappo, Stefania; Naitza, Silvia; Neph, Shane; Nord, Alex S.; Nutile, Teresa; Okin, Peter M.; Olsen, Jesper V.; Oostra, Ben A.; Penninger, Josef M.; Pennacchio, Len A.; Pers, Tune H.; Perz, Siegfried; Peters, Annette; Pinto, Yigal M.; Pfeufer, Arne; Pilia, Maria Grazia; Pramstaller, Peter P.; Prins, Bram P.; Raitakari, Olli T.; Raychaudhuri, Soumya; Rice, Ken M.; Rossin, Elizabeth J.; Rotter, Jerome I.; Schafer, Sebastian; Schlessinger, David; Schmidt, Carsten O.; Sehmi, Jobanpreet; Silljé, Herman H.W.; Sinagra, Gianfranco; Sinner, Moritz F.; Slowikowski, Kamil; Soliman, Elsayed Z.; Spector, Timothy D.; Spiering, Wilko; Stamatoyannopoulos, John A.; Stolk, Ronald P.; Strauch, Konstantin; Tan, Sian-Tsung; Tarasov, Kirill V.; Trinh, Bosco; Uitterlinden, Andre G.; van den Boogaard, Malou; van Duijn, Cornelia M.; van Gilst, Wiek H.; Viikari, Jorma S.; Visscher, Peter M.; Vitart, Veronique; Völker, Uwe; Waldenberger, Melanie; Weichenberger, Christian X.; Westra, Harm-Jan; Wijmenga, Cisca; Wolffenbuttel, Bruce H.; Yang, Jian; Bezzina, Connie R.; Munroe, Patricia B.; Snieder, Harold; Wright, Alan F.; Rudan, Igor; Boyer, Laurie A.; Asselbergs, Folkert W.; van Veldhuisen, Dirk J.; Stricker, Bruno H.; Psaty, Bruce M.; Ciullo, Marina; Sanna, Serena; Lehtimäki, Terho; Wilson, James F.; Bandinelli, Stefania; Alonso, Alvaro; Gasparini, Paolo; Jukema, J. Wouter; Kääb, Stefan; Gudnason, Vilmundur; Felix, Stephan B.; Heckbert, Susan R.; de Boer, Rudolf A.; Newton-Cheh, Christopher; Hicks, Andrew A.; Chambers, John C.; Jamshidi, Yalda; Visel, Axel; Christoffels, Vincent M.; Isaacs, Aaron; Samani, Nilesh J.; de Bakker, Paul I.W.

    2017-01-01

    BACKGROUND Myocardial mass is a key determinant of cardiac muscle function and hypertrophy. Myocardial depolarization leading to cardiac muscle contraction is reflected by the amplitude and duration of the QRS complex on the electrocardiogram (ECG). Abnormal QRS amplitude or duration reflect changes in myocardial mass and conduction, and are associated with increased risk of heart failure and death. OBJECTIVES This meta-analysis sought to gain insights into the genetic determinants of myocardial mass. METHODS We carried out a genome-wide association meta-analysis of 4 QRS traits in up to 73,518 individuals of European ancestry, followed by extensive biological and functional assessment. RESULTS We identified 52 genomic loci, of which 32 are novel, that are reliably associated with 1 or more QRS phenotypes at p < 1 × 10−8. These loci are enriched in regions of open chromatin, histone modifications, and transcription factor binding, suggesting that they represent regions of the genome that are actively transcribed in the human heart. Pathway analyses provided evidence that these loci play a role in cardiac hypertrophy. We further highlighted 67 candidate genes at the identified loci that are preferentially expressed in cardiac tissue and associated with cardiac abnormalities in Drosophila melanogaster and Mus musculus. We validated the regulatory function of a novel variant in the SCN5A/SCN10A locus in vitro and in vivo. CONCLUSIONS Taken together, our findings provide new insights into genes and biological pathways controlling myocardial mass and may help identify novel therapeutic targets. PMID:27659466

  6. Characteristics of Responders to Cardiac Resynchronization Therapy: The Impact of Echocardiographic Left Ventricular Volume

    PubMed Central

    Park, Mi Young; Altman, Robert K.; Orencole, Mary; Kumar, Prabhat; Parks, Kimberly A.; Heist, Kevin E.; Singh, Jagmeet P.; Picard, Michael H.

    2012-01-01

    Summary Background One third of patients who receive cardiac resynchronization therapy (CRT) are classified as nonresponders. Characteristics of responders to CRT have been studied in multiple clinical trials. Hypothesis We aimed to examine characteristics of CRT responders in a routine clinical practice. Method One hundred and twenty five patients were examined retrospectively from a multidisciplinary CRT clinic program. Echocardiographic CRT response was defined as a decrease in left ventricular (LV) end systolic volume (ESV) of ≥ 15% and/or absolute increase of 5% in LV ejection fraction (EF) at 6 month visit. Results There were 81 responders and 44 nonresponders. By univariate analyses, female gender, nonischemic cardiomyopathy etiology, baseline QRS duration, the presence of left bundle branch block (LBBB) and left ventricular end-diastolic volume (LVEDV) index predicted CRT response. However, multivariate analysis demonstrated only QRS duration, LBBB and LVEDV index were independent predictors (QRS width: Odd ratio [OR] 1.027, 95% CI 1.004 – 1.050, p = 0.023; LBBB: OR 3.568, 95% CI 1.284 – 9.910, p=0.015; LV EDV index: OR 0.970, 95% CI 0.953 – 0.987, p= 0.001). While female gender and nonischemic etiology were associated with an improved CRT response on univariate analyses, after adjusting for LV volumes, they were not independent predictors. Conclusion QRS width, LBBB and LVEDV index are independent predictors for echocardiographic CRT response. Previously reported differences in CRT response for gender and cardiomyopathy etiology are associated with differences in baseline LV volumes in our clinical practice. PMID:22886700

  7. Evaluation of clinical and electrocardiographic changes during the euthanasia of horses.

    PubMed

    Buhl, R; Andersen, L O F; Karlshøj, M; Kanters, J K

    2013-06-01

    The objective of this prospective field study was to investigate whether commonly used criteria for clinical death occurred at the same time as cardiac death, as determined by electrocardiography. Specific ECG changes during euthanasia were also studied. Twenty-nine horses were euthanized with pentobarbital at two different dose rates and 15 of the 29 horses also received detomidine hydrochloride for sedation. ECG was recorded prior to and during euthanasia. Time to collapse, cessation of reflexes, heart sounds and asystole were recorded. ECG recordings were used to calculate RR intervals, PQ duration, QRS duration, distance from QRS complex to end of T wave corrected for HR (QTc interval), duration of T-wave from peak to end (TpeakTend) and amplitudes of T wave (Tpeak) before and during euthanasia. Differences between groups and ECG changes were evaluated using analysis of variance. Clinical determination of death occurred before cardiac death (P<0.05). Sedated horses took longer to collapse than unsedated horses (P<0.0001), but asystole occurred faster in sedated horses (P<0.0001). No significant changes in QRS duration were observed, but RR, PQ, QTc, TpeakTend and Tpeak were influenced by both pentobarbital dose and sedation (P<0.05-<0.0001). In conclusion, sedation prior to euthanasia resulted in a shorter time to asystole and is therefore recommended for the euthanasia of horses. Importantly, the results show that the clinical definition of death occurred significantly earlier than cardiac death (defined as asystole), which indicates that the clinical declaration of death in horses could be premature compared to that used in humans. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Universal algorithm for diagnosis of biventricular capture in patients with cardiac resynchronization therapy.

    PubMed

    Jastrzebski, Marek; Kukla, Piotr; Fijorek, Kamil; Czarnecka, Danuta

    2014-08-01

    An accurate and universal method for diagnosis of biventricular (BiV) capture using a standard 12-lead electrocardiogram (ECG) would be useful for assessment of cardiac resynchronization therapy (CRT) patients. Our objective was to develop and validate such an ECG method for BiV capture diagnosis that would be independent of pacing lead positions-a major confounder that significantly influences the morphologies of paced QRS complexes. On the basis of an evaluation of 789 ECGs of 443 patients with heart failure and various right ventricular (RV) and left ventricular (LV) lead positions, the following algorithm was constructed and validated. BiV capture was diagnosed if the QRS in lead I was predominantly negative and either V1 QRS was predominantly positive or V6 QRS was of negative onset and predominantly negative (step 1), or if QRS complex duration was <160 ms (step 2). All other ECGs were classified as loss of LV capture. The algorithm showed good accuracy (93%), sensitivity (97%), and specificity (90%) for detection of loss of LV capture. The performance of the algorithm did not differ among apical, midseptal, and outflow tract RV lead positions and various LV lead positions. LV capture leaves diagnostic hallmarks in the fused BiV QRS related to different vectors of depolarization and more rapid depolarization of the ventricles. An accurate two-step ECG algorithm for BiV capture diagnosis was developed and validated. This algorithm is universally applicable to all CRT patients, regardless of the positions of the pacing leads. ©2014 Wiley Periodicals, Inc.

  9. Value of the Signal-Averaged Electrocardiogram in Arrhythmogenic Right Ventricular Cardiomyopathy/Dysplasia

    PubMed Central

    Kamath, Ganesh S.; Zareba, Wojciech; Delaney, Jessica; Koneru, Jayanthi N.; McKenna, William; Gear, Kathleen; Polonsky, Slava; Sherrill, Duane; Bluemke, David; Marcus, Frank; Steinberg, Jonathan S.

    2011-01-01

    Background Arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D) is an inherited disease causing structural and functional abnormalities of the right ventricle (RV). The presence of late potentials as assessed by the signal averaged electrocardiogram (SAECG) is a minor Task Force criterion. Objective The purpose of this study was to examine the diagnostic and clinical value of the SAECG in a large population of genotyped ARVC/D probands. Methods We compared the SAECGs of 87 ARVC/D probands (age 37 ± 13 years, 47 males) diagnosed as affected or borderline by Task Force criteria without using the SAECG criterion with 103 control subjects. The association of SAECG abnormalities was also correlated with clinical presentation; surface ECG; VT inducibility at electrophysiologic testing; ICD therapy for VT; and RV abnormalities as assessed by cardiac magnetic resonance imaging (cMRI). Results When compared with controls, all 3 components of the SAECG were highly associated with the diagnosis of ARVC/D (p<0.001). These include the filtered QRS duration (fQRSD) (97.8 ± 8.7 msec vs. 119.6 ± 23.8 msec), low amplitude signal (LAS) (24.4 ± 9.2 msec vs. 46.2 ± 23.7 msec) and root mean square amplitude of the last 40 msec of late potentials (RMS-40) (50.4 ± 26.9 µV vs. 27.9 ± 36.3 µV). The sensitivity of using SAECG for diagnosis of ARVC/D was increased from 47% using the established 2 of 3 criteria (i.e. late potentials) to 69% by using a modified criterion of any 1 of the 3 criteria, while maintaining a high specificity of 95%. Abnormal SAECG as defined by this modified criteria was associated with a dilated RV volume and decreased RV ejection fraction detected by cMRI (p<0.05). SAECG abnormalities did not vary with clinical presentation or reliably predict spontaneous or inducible VT, and had limited correlation with ECG findings. Conclusion Using 1 of 3 SAECG criteria contributed to increased sensitivity and specificity for the diagnosis of ARVC/D. This

  10. Surface ECG and Fluoroscopy are Not Predictive of Right Ventricular Septal Lead Position Compared to Cardiac CT.

    PubMed

    Rowe, Matthew K; Moore, Peter; Pratap, Jit; Coucher, John; Gould, Paul A; Kaye, Gerald C

    2017-05-01

    Controversy exists regarding the optimal lead position for chronic right ventricular (RV) pacing. Placing a lead at the RV septum relies upon fluoroscopy assisted by a surface 12-lead electrocardiogram (ECG). We compared the postimplant lead position determined by ECG-gated multidetector contrast-enhanced computed tomography (MDCT) with the position derived from the surface 12-lead ECG. Eighteen patients with permanent RV leads were prospectively enrolled. Leads were placed in the RV septum (RVS) in 10 and the RV apex (RVA) in eight using fluoroscopy with anteroposterior and left anterior oblique 30° views. All patients underwent MDCT imaging and paced ECG analysis. ECG criteria were: QRS duration; QRS axis; positive or negative net QRS amplitude in leads I, aVL, V1, and V6; presence of notching in the inferior leads; and transition point in precordial leads at or after V4. Of the 10 leads implanted in the RVS, computed tomography (CT) imaging revealed seven to be at the anterior RV wall, two at the anteroseptal junction, and one in the true septum. For the eight RVA leads, four were anterior, two septal, and two anteroseptal. All leads implanted in the RVS met at least one ECG criteria (median 3, range 1-6). However, no criteria were specific for septal position as judged by MDCT. Mean QRS duration was 160 ± 24 ms in the RVS group compared with 168 ± 14 ms for RVA pacing (P = 0.38). We conclude that the surface ECG is not sufficiently accurate to determine RV septal lead tip position compared to cardiac CT. © 2017 Wiley Periodicals, Inc.

  11. Cardiac resynchronization therapy with His bundle pacing as a method of treatment of chronic heart failure in patients with permanent atrial fibrillation and left bundle branch block.

    PubMed

    Boczar, Krzysztof; Sławuta, Agnieszka; Ząbek, Andrzej; Dębski, Maciej; Gajek, Jacek; Lelakowski, Jacek; Małecka, Barbara

    CRT is a therapeutic option for patients with heart failure, sinus rhythm, prolonged QRS complex duration and reduced ejection fraction. We present a case of 71-year-old woman with dilated cardiomyopathy, NYHA functional class III and AF. We implanted CRT combined with direct His-bundle pacing. The indication for such a therapy was a left bundle branch block with a QRS complex of 178ms and a left ventricular EF of 15%, left ventricular end-diastolic diameter (LVEDD) of 75mm. After 8months of follow-up the LVEDD was 60mm with EF 35-40%. Copyright © 2017. Published by Elsevier Inc.

  12. Bicarbonate refractory QRS prolongation and left bundle-branch block following escitalopram and lamotrigine overdose: A case report and literature review of toxic left bundle-branch block.

    PubMed

    Farkas, A N; Marcott, M; Yanta, J H; Pizon, A F

    2018-05-02

    Toxic prolongation of the QRS interval most often results from blockade of cardiac voltage-gated sodium channels and manifests on electrocardiogram with a right bundle-branch block-like morphology. Rarely, a left bundle-branch block (LBBB) morphology has been reported. We report a case of transient LBBB resultant from ingestion of lamotrigine and citalopram which was refractory to sodium bicarbonate therapy and eventually resolved spontaneously. Cases of toxic LBBB are less likely to respond to bicarbonate therapy, suggesting that this finding is due to a mechanism other than sodium channel blockade. © 2018 John Wiley & Sons Ltd.

  13. Triple-site pacing for cardiac resynchronization in permanent atrial fibrillation - Acute phase results from a prospective observational study.

    PubMed

    Marques, Pedro; Nobre Menezes, Miguel; Lima da Silva, Gustavo; Bernardes, Ana; Magalhães, Andreia; Cortez-Dias, Nuno; Carpinteiro, Luís; de Sousa, João; Pinto, Fausto J

    2016-06-01

    Multi-site pacing is emerging as a new method for improving response to cardiac resynchronization therapy (CRT), but has been little studied, especially in patients with atrial fibrillation. We aimed to assess the effects of triple-site (Tri-V) vs. biventricular (Bi-V) pacing on hemodynamics and QRS duration. This was a prospective observational study of patients with permanent atrial fibrillation and ejection fraction <40% undergoing CRT implantation (n=40). One right ventricular (RV) lead was implanted in the apex and another in the right ventricular outflow tract (RVOT) septal wall. A left ventricular (LV) lead was implanted in a conventional venous epicardial position. Cardiac output (using the FloTrac™ Vigileo™ system), mean QRS and ejection fraction were calculated. Mean cardiac output was 4.81±0.97 l/min with Tri-V, 4.68±0.94 l/min with RVOT septal and LV pacing, and 4.68±0.94 l/min with RV apical and LV pacing (p<0.001 for Tri-V vs. both BiV). Mean pre-implantation QRS was 170±25 ms, 123±18 ms with Tri-V, 141±25 ms with RVOT septal pacing and LV pacing and 145±19 with RV apical and LV pacing (p<0.001 for Tri-V vs. both BiV and pre-implantation). Mean ejection fraction was significantly higher with Tri-V (30±11%) vs. Bi-V pacing (28±12% with RVOT septal and LV pacing and 28±11 with RV apical and LV pacing) and pre-implantation (25±8%). Tri-V pacing produced higher cardiac output and shorter QRS duration than Bi-V pacing. This may have a significant impact on the future of CRT. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  14. Machine Learning Algorithm Predicts Cardiac Resynchronization Therapy Outcomes: Lessons From the COMPANION Trial.

    PubMed

    Kalscheur, Matthew M; Kipp, Ryan T; Tattersall, Matthew C; Mei, Chaoqun; Buhr, Kevin A; DeMets, David L; Field, Michael E; Eckhardt, Lee L; Page, C David

    2018-01-01

    Cardiac resynchronization therapy (CRT) reduces morbidity and mortality in heart failure patients with reduced left ventricular function and intraventricular conduction delay. However, individual outcomes vary significantly. This study sought to use a machine learning algorithm to develop a model to predict outcomes after CRT. Models were developed with machine learning algorithms to predict all-cause mortality or heart failure hospitalization at 12 months post-CRT in the COMPANION trial (Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure). The best performing model was developed with the random forest algorithm. The ability of this model to predict all-cause mortality or heart failure hospitalization and all-cause mortality alone was compared with discrimination obtained using a combination of bundle branch block morphology and QRS duration. In the 595 patients with CRT-defibrillator in the COMPANION trial, 105 deaths occurred (median follow-up, 15.7 months). The survival difference across subgroups differentiated by bundle branch block morphology and QRS duration did not reach significance ( P =0.08). The random forest model produced quartiles of patients with an 8-fold difference in survival between those with the highest and lowest predicted probability for events (hazard ratio, 7.96; P <0.0001). The model also discriminated the risk of the composite end point of all-cause mortality or heart failure hospitalization better than subgroups based on bundle branch block morphology and QRS duration. In the COMPANION trial, a machine learning algorithm produced a model that predicted clinical outcomes after CRT. Applied before device implant, this model may better differentiate outcomes over current clinical discriminators and improve shared decision-making with patients. © 2018 American Heart Association, Inc.

  15. Studies on deflection area vectors of QRS and T and ventricular gradient in right ventricular hypertrophy.

    PubMed

    Kawaguchi, Y

    1985-04-01

    QRS deflection area vector (Aqrs), T deflection area vector (At) and ventricular gradient (G) in right ventricular hypertrophy were studied in 53 subjects divided on the basis of cardiac catheterization data into four subgroups; normal controls, mild MS group, right ventricular pressure overload group and right ventricular volume overload group. Aqrs, At and G of the four subgroups were calculated using a microcomputer and compared. Aqrs in right ventricular pressure overload group and volume overload group was shifted to the right and slightly anteriorly from that in normal control group. At in right ventricular pressure overload group and volume overload group was shifted slightly upwards and significantly posteriorly from that in the normal control and mild MS groups. G in right ventricular pressure overload group and volume overload group was shifted to the right and significantly posteriorly from that in normal control and mild MS groups. Using multivariative analysis, we developed criteria for diagnosing right ventricular hypertrophy with At: 0.059At(Z) - 0.0145 [At] - 0.2608 less than or equal to 0. Application of this criteria achieved 82.4% (28 of 34) sensitivity in the patients with right ventricular hypertrophy and 90.9% (10 of 11) specificity in the normal control subjects.

  16. Advanced Electrocardiography Can Identify Occult Cardiomyopathy in Doberman Pinschers

    NASA Technical Reports Server (NTRS)

    Spiljak, M.; Petric, A. Domanjko; Wilberg, M.; Olsen, L. H.; Stepancic, A.; Schlegel, T. T.; Starc, V.

    2011-01-01

    Recently, multiple advanced resting electrocardiographic (A-ECG) techniques have improved the diagnostic value of short-duration ECG in detection of dilated cardiomyopathy (DCM) in humans. This study investigated whether 12-lead A-ECG recordings could accurately identify the occult phase of DCM in dogs. Short-duration (3-5 min) high-fidelity 12-lead ECG recordings were obtained from 31 privately-owned, clinically healthy Doberman Pinschers (5.4 +/- 1.7 years, 11/20 males/females). Dogs were divided into 2 groups: 1) 19 healthy dogs with normal echocardiographic M-mode measurements: left ventricular internal diameter in diastole (LVIDd . 47mm) and in systole (LVIDs . 38mm) and normal 24-hour ECG recordings (<50 ventricular premature complexes, VPCs); and 2) 12 dogs with occult DCM: 11/12 dogs had increased M-mode measurements (LVIDd . 49mm and/or LVIDs . 40mm) and 5/11 dogs had also >100 VPCs/24h; 1/12 dogs had only abnormal 24-hour ECG recordings (>100 VPCs/24h). ECG recordings were evaluated via custom software programs to calculate multiple parameters of high-frequency (HF) QRS ECG, heart rate variability, QT variability, waveform complexity and 3-D ECG. Student's t-tests determined 19 ECG parameters that were significantly different (P < 0.05) between groups. Principal component factor analysis identified a 5-factor model with 81.4% explained variance. QRS dipolar and non-dipolar voltages, Cornell voltage criteria and QRS waveform residuum were increased significantly (P < 0.05), whereas mean HF QRS amplitude was decreased significantly (P < 0.05) in dogs with occult DCM. For the 5 selected parameters the prediction of occult DCM was performed using a binary logistic regression model with Chi-square tested significance (P < 0.01). ROC analyses showed that the five selected ECG parameters could identify occult ECG with sensitivity 89% and specificity 83%. Results suggest that 12-lead A-ECG might improve diagnostic value of short-duration ECG in earlier detection

  17. Non-selective His bundle pacing with a biphasic waveform: enhancing septal resynchronization.

    PubMed

    Ortega, Daniel F; Barja, Luis D; Logarzo, Emilio; Mangani, Nicolas; Paolucci, Analia; Bonomini, Maria P

    2018-05-01

    His bundle pacing has shown to prevent detrimental effects from right ventricular apical pacing (RVA) and proved to resynchronize many conduction disturbances cases. However, the extent of His bundle pacing resynchronization is limited. An optimized stimulation waveform could expand this limit when implemented in His bundle pacing sets. In this work, we temporarily implemented RVA and Non-selective His bundle pacing with a biphasic anodal-first waveform (AF-nHB) and compared their effects against sinus rhythm (SR). Fifteen patients referred for electrophysiologic study with conduction disturbances, cardiomyopathy and ejection fraction below 35% were enrolled for the study. The following acute parameters were measured: QRS duration, left ventricular activation (RLVT), time of isovolumic contraction (IVCT), ejection fraction (EF), and dP/dtmax. QRS duration and RLVT decreased markedly under AF-nHB (SR: 169 ± 34 ms vs. nHB: 116 ± 31 ms, P < 0.0005) while RVA significantly increased QRS duration (SR: 169 ms vs. RVA: 198 ms, P < 0.05) and did not change RLVT (P = NS). Consistently, IVCT moderately decreased under AF-nHB (SR: 238 ms vs. RVA: 184 ms, P < 0.05 vs. SR) and dP/dtmax showed a 93.35 [mmHg] average increase under AF-nHB against SR. Also, T-wave inversions were observed during AF-nHB immediately after SR and RVA pacing suggesting the occurrence of cardiac memory. AF-nHB corrected bundle branch blocks in patients with severe conduction disturbances, even in those with dilated cardiomiopathy, outstanding from RVA. Also, the occurrence of cardiac memory during AF-nHB turned up as an observational finding of this study.

  18. Late deterioration of left ventricular function after right ventricular pacemaker implantation.

    PubMed

    Bellmann, Barbara; Muntean, Bogdan G; Lin, Tina; Gemein, Christopher; Schmitz, Kathrin; Schauerte, Patrick

    2016-09-01

    Right ventricular (RV) pacing induces a left bundle branch block pattern on ECG and may promote heart failure. Patients with dual chamber pacemakers (DCPs) who present with progressive reduction in left ventricular ejection fraction (LVEF) secondary to RV pacing are candidates for cardiac resynchronization therapy (CRT). This study analyzes whether upgrading DCP to CRT with the additional implantation of a left ventricular (LV) lead improves LV function in patients with reduced LVEF following DCP implantation. Twenty-two patients (13 males) implanted with DCPs and a high RV pacing percentage (>90%) were evaluated in term of new-onset heart failure symptoms. The patients were enrolled in this retrospective single-center study after obvious causes for a reduced LVEF were excluded with echocardiography and coronary angiography. In all patients, DCPs were then upgraded to biventricular devices. LVEF was analyzed with a two-sided t-test. QRS duration and brain natriuretic peptide (BNP) levels were analyzed with the unpaired t-test. LVEF declined after DCP implantation from 54±10% to 31±7%, and the mean QRS duration was 161±20 ms during RV pacing. NT-pro BNP levels were elevated (3365±11436 pmol/L). After upgrading to a biventricular device, a biventricular pacing percentage of 98.1±2% was achieved. QRS duration decreased to 108±16 ms and 106±20 ms after 1 and 6 months, respectively. There was a significant increase in LVEF to 38±8% and 41±11% and a decrease in NT-pro BNP levels to 3088±2326 pmol/L and 1860±1838 pmol/L at 1 and 6 months, respectively. Upgrading to CRT may be beneficial in patients with DCPs and heart failure induced by a high RV pacing percentage.

  19. A feasible approach for direct his-bundle pacing using a new steerable catheter to facilitate precise lead placement.

    PubMed

    Zanon, Francesco; Baracca, Enrico; Aggio, Silvio; Pastore, Gianni; Boaretto, Graziano; Cardano, Paola; Marotta, Tiziana; Rigatelli, Gianluca; Galasso, Mariapaola; Carraro, Mauro; Zonzin, Pietro

    2006-01-01

    Much clinical evidence has shown that right ventricular (RV) apical pacing is detrimental to left ventricular function. Preservation of the use of the His-Purkinje (H-P) system may be ideal in heart block that is restricted to the AV node, but may be of no benefit when H-P disease exists. To investigate the feasibility of direct His-bundle pacing (DHBP) using a new system consisting of a steerable catheter and a new 4.1 F screw-in lead. Between May and December 2004, 26 patients (19 male, mean age: 77 +/- 5 years) with a standard pacemaker (PM) indication and preserved His-bundle conduction were enrolled and DHBP was attempted. DHBP was achieved in 24 patients (92%); two patients were paced in the His area, but the paced QRS morphology and duration were different from the native QRS. The mean time for lead positioning was 19 +/- 17 minutes, the mean fluoroscopy time was 11 +/- 8 minutes, and the total procedure time (skin-to-skin including positioning of a quadripolar diagnostic catheter for His recording) was 75 +/- 18 minutes. In DHBP pacing, the acute pacing threshold was 2.3 +/- 1.0 V at a pulse duration of 0.5 msec, and the sensed potentials were 2.9 +/- 2.0 mV. At a 3-month follow-up examination, the same QRS duration and morphology recorded on implantation were observed in all patients. The pacing threshold was 2.8 +/- 1.4 V, and sensed potentials were 2.5 +/- 1.8 mV; the sensing configuration was changed from bipolar to unipolar in 6 patients to resolve undersensing issues. No major complications were observed. This feasibility study shows that DHBP can be accomplished with a new system consisting of a steerable catheter and an active fixation lead in 92% of the patients in whom it was attempted.

  20. Electroconvulsive therapy-induced Wolff-Parkinson-White syndrome: a case report.

    PubMed

    Enomoto, Shingo; Yoshino, Aihide; Takase, Bonpei; Kuwahara, Tatsuro; Tatsuzawa, Yasutaka; Nomura, Soichiro

    2013-01-01

    Wolff-Parkinson-White (WPW) syndrome is characterized by premature ventricular excitation due to the presence of an abnormal accessory pathway. Electrocardiography (ECG) of patients with WPW syndrome portrays a short PR interval and a wide QRS interval with a delta wave. Herein, we report the case of a patient with schizophrenia who developed a wide QRS interval with a delta wave immediately following electroconvulsive therapy (ECT). Initially, the delta wave disappeared within 2 days after ECT. However, the duration of the delta wave increased exponentially to 4 months when ECT was repeated. Although the patient's cardiocirculatory dynamics remained normal, we continued to monitor her ECG until the delta wave disappeared because WPW syndrome can lead to serious arrhythmia. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Aging modulates dispersion of ventricular repolarization in the very old of the geriatric population.

    PubMed

    Huang, Jen-Hung; Lin, Ying-Qin; Pan, Nan-Hung; Chen, Yi-Jen

    2010-11-01

    Aging plays an essential role in cardiac pathophysiology. Knowledge on the ventricular repolarization in very old individuals is limited. An increase of QT dispersion is associated with higher cardiovascular mortality. The purpose of this study is to investigate whether aging changes the QT dispersion in the very old. Heart rate, P wave duration, PR interval, QRS axis, QRS duration, QT interval, and QTc interval were measured from 12-lead resting ECG. QT dispersion (46 ± 21, 47 ± 17, 69 ± 31 ms, p < 0.005) was significantly increased in the age group ≧85 years (n = 29, 89 ± 4 years) than in the age group 75-84 years (n = 33, 79 ± 3 years) and the age group 65-74 years (n = 32, 68 ± 3 years). Aging modulates dispersion of ventricular repolarization, which may contribute to the cardiac mortality in the very old Asian population.

  2. QRS/T-wave and calcium alternans in a type I diabetic mouse model for spontaneous postmyocardial infarction ventricular tachycardia: A mechanism for the antiarrhythmic effect of statins.

    PubMed

    Jin, Hongwei; Welzig, Charles M; Aronovitz, Mark; Noubary, Farzad; Blanton, Robert; Wang, Bo; Rajab, Mohammad; Albano, Alfred; Link, Mark S; Noujaim, Sami F; Park, Ho-Jin; Galper, Jonas B

    2017-09-01

    The incidence of sudden arrhythmic death is markedly increased in diabetics. The purpose of this study was to develop a mouse model for postmyocardial infarction (post-MI) ventricular tachycardia (VT) in the diabetic heart and determine the mechanism of an antiarrhythmic effect of statins. ECG transmitters were implanted in wild-type (WT), placebo, and pravastatin-treated type I diabetic Akita mice. MIs were induced by coronary ligation, and Ca 2+ transients were studied by optical mapping, and Ca 2+ transients and sparks in left ventricular myocytes (VM) by the Ionoptix system and confocal microscopy. Burst pacing of Akita mouse hearts resulted in rate-related QRS/T-wave alternans, which was attenuated in pravastatin-treated mice. Post-MI Akita mice developed QRS/T-wave alternans and VT at 2820 ± 879 beats per mouse, which decreased to 343 ± 115 in pravastatin-treated mice (n = 13, P <.05). Optical mapping demonstrated pacing-induced VT originating in the peri-infarction zone and Ca 2+ alternans, both attenuated in hearts of statin-treated mice. Akita VM displayed Ca 2+ alternans, and triggered activity as well as increased Ca 2+ transient decay time (Tau), Ca 2+ sparks, and cytosolic Ca 2+ and decreased SR Ca 2+ stores all of which were in part reversed in cells from statin treated mice. Homogenates of Akita ventricles demonstrated decreased SERCA2a/PLB ratio and increased ratio of protein phosphatase (PP-1) to the PP-1 inhibitor PPI-1 which were reversed in homogenates of pravastatin-treated Akita mice. Pravastatin decreased the incidence of post-MI VT and Ca 2+ alternans in Akita mouse hearts in part by revering abnormalities of Ca 2+ handling via the PP-1/PPI-1 pathway. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  3. Cardiac-resynchronization therapy for mild-to-moderate heart failure.

    PubMed

    Tang, Anthony S L; Wells, George A; Talajic, Mario; Arnold, Malcolm O; Sheldon, Robert; Connolly, Stuart; Hohnloser, Stefan H; Nichol, Graham; Birnie, David H; Sapp, John L; Yee, Raymond; Healey, Jeffrey S; Rouleau, Jean L

    2010-12-16

    Cardiac-resynchronization therapy (CRT) benefits patients with left ventricular systolic dysfunction and a wide QRS complex. Most of these patients are candidates for an implantable cardioverter-defibrillator (ICD). We evaluated whether adding CRT to an ICD and optimal medical therapy might reduce mortality and morbidity among such patients. We randomly assigned patients with New York Heart Association (NYHA) class II or III heart failure, a left ventricular ejection fraction of 30% or less, and an intrinsic QRS duration of 120 msec or more or a paced QRS duration of 200 msec or more to receive either an ICD alone or an ICD plus CRT. The primary outcome was death from any cause or hospitalization for heart failure. We followed 1798 patients for a mean of 40 months. The primary outcome occurred in 297 of 894 patients (33.2%) in the ICD-CRT group and 364 of 904 patients (40.3%) in the ICD group (hazard ratio in the ICD-CRT group, 0.75; 95% confidence interval [CI], 0.64 to 0.87; P<0.001). In the ICD-CRT group, 186 patients died, as compared with 236 in the ICD group (hazard ratio, 0.75; 95% CI, 0.62 to 0.91; P = 0.003), and 174 patients were hospitalized for heart failure, as compared with 236 in the ICD group (hazard ratio, 0.68; 95% CI, 0.56 to 0.83; P<0.001). However, at 30 days after device implantation, adverse events had occurred in 124 patients in the ICD-CRT group, as compared with 58 in the ICD group (P<0.001). Among patients with NYHA class II or III heart failure, a wide QRS complex, and left ventricular systolic dysfunction, the addition of CRT to an ICD reduced rates of death and hospitalization for heart failure. This improvement was accompanied by more adverse events. (Funded by the Canadian Institutes of Health Research and Medtronic of Canada; ClinicalTrials.gov number, NCT00251251.).

  4. Classification of ECG signal with Support Vector Machine Method for Arrhythmia Detection

    NASA Astrophysics Data System (ADS)

    Turnip, Arjon; Ilham Rizqywan, M.; Kusumandari, Dwi E.; Turnip, Mardi; Sihombing, Poltak

    2018-03-01

    An electrocardiogram is a potential bioelectric record that occurs as a result of cardiac activity. QRS Detection with zero crossing calculation is one method that can precisely determine peak R of QRS wave as part of arrhythmia detection. In this paper, two experimental scheme (2 minutes duration with different activities: relaxed and, typing) were conducted. From the two experiments it were obtained: accuracy, sensitivity, and positive predictivity about 100% each for the first experiment and about 79%, 93%, 83% for the second experiment, respectively. Furthermore, the feature set of MIT-BIH arrhythmia using the support vector machine (SVM) method on the WEKA software is evaluated. By combining the available attributes on the WEKA algorithm, the result is constant since all classes of SVM goes to the normal class with average 88.49% accuracy.

  5. Pulmonary Right Ventricular Resynchronization in Congenital Heart Disease: Acute Improvement in Right Ventricular Mechanics and Contraction Efficiency.

    PubMed

    Janoušek, Jan; Kovanda, Jan; Ložek, Miroslav; Tomek, Viktor; Vojtovič, Pavel; Gebauer, Roman; Kubuš, Peter; Krejčíř, Miroslav; Lumens, Joost; Delhaas, Tammo; Prinzen, Frits

    2017-09-01

    Electromechanical discoordination may contribute to long-term pulmonary right ventricular (RV) dysfunction in patients after surgery for congenital heart disease. We sought to evaluate changes in RV function after temporary RV cardiac resynchronization therapy. Twenty-five patients aged median 12.0 years after repair of tetralogy of Fallot and similar lesions were studied echocardiographically (n=23) and by cardiac catheterization (n=5) after primary repair (n=4) or after surgical RV revalvulation for significant pulmonary regurgitation (n=21). Temporary RV cardiac resynchronization therapy was applied in the presence of complete right bundle branch block by atrial-synchronized RV free wall pacing in complete fusion with spontaneous ventricular depolarization using temporary electrodes. The q-RV interval at the RV free wall pacing site (mean 77.2% of baseline QRS duration) confirmed pacing from a late activated RV area. RV cardiac resynchronization therapy carried significant decrease in QRS duration ( P <0.001) along with elimination of the right bundle branch block QRS morphology, increase in RV filling time ( P =0.002), pulmonary artery velocity time integral ( P =0.006), and RV maximum +dP/dt ( P <0.001), and decrease in RV index of myocardial performance ( P =0.006). RV mechanical synchrony improved: septal-to-lateral RV mechanical delay decreased ( P <0.001) and signs of RV dyssynchrony pattern were significantly abolished. RV systolic stretch fraction reflecting the ratio of myocardial stretching and contraction during systole diminished ( P =0.001). In patients with congenital heart disease and right bundle branch block, RV cardiac resynchronization therapy carried multiple positive effects on RV mechanics, synchrony, and contraction efficiency. © 2017 American Heart Association, Inc.

  6. The effect of sport on computerized electrocardiogram measurements in college athletes.

    PubMed

    Gademan, Maaike G J; Uberoi, Abhimanyu; Le, Vy-Van; Mandic, Sandra; van Oort, Eddy R; Myers, Jonathan; Froelicher, Victor F

    2012-02-01

    Broad criteria for abnormal electrocardiogram (ECG) findings, requiring additional testing, have been recommended for preparticipation exams (PPE) of athletes. As these criteria have not considered the sport in which athletes participate, we examined the effect of sports on the computerized ECG measurements obtained in college athletes. During the Stanford 2007 PPE, computerized 12-lead ECGs (Schiller AG) were obtained in 641 athletes (350 male/291 female, age 19.5 ± 2 years). Athletes were engaged in 22 different sports and were grouped into 16 categories: baseball/softball, basketball, crew, crosscountry, fencing, field events, football linemen, football other positions, golf, gymnastics, racquet sports, sailing, track/field, volleyball, water sports, and wrestling. The analysis focused on ECG leads V2, aVF and V5 which provide a three-dimensional representation of the heart's electrical activity. As marked ECG differences exist between males and females, the data are presented by gender. In males, ANOVA analysis yielded significant ECG differences between sports for heart rate, QRS duration, QTc, J-amplitude in V2 and V5, spatial vector length (SVL) of the P wave, SVL R wave, and SVL T wave, and RS(sum) (p < 0.05). In females ECG differences between sports were found for heart rate, QRS duration, QRS axis and SVL T wave (p < 0.05). Poor correlations were found between body dimensions and ECG measurements (r < 0.50). Significant ECG changes exist between college athletes participating in different sports, and these differences were more apparent in males than females. Therefore, sport-specific ECG criteria for abnormal ECG findings should be developed to obtain a more useful approach to ECG screening in athletes.

  7. ECG-ViEW II, a freely accessible electrocardiogram database

    PubMed Central

    Park, Man Young; Lee, Sukhoon; Jeon, Min Seok; Yoon, Dukyong; Park, Rae Woong

    2017-01-01

    The Electrocardiogram Vigilance with Electronic data Warehouse II (ECG-ViEW II) is a large, single-center database comprising numeric parameter data of the surface electrocardiograms of all patients who underwent testing from 1 June 1994 to 31 July 2013. The electrocardiographic data include the test date, clinical department, RR interval, PR interval, QRS duration, QT interval, QTc interval, P axis, QRS axis, and T axis. These data are connected with patient age, sex, ethnicity, comorbidities, age-adjusted Charlson comorbidity index, prescribed drugs, and electrolyte levels. This longitudinal observational database contains 979,273 electrocardiograms from 461,178 patients over a 19-year study period. This database can provide an opportunity to study electrocardiographic changes caused by medications, disease, or other demographic variables. ECG-ViEW II is freely available at http://www.ecgview.org. PMID:28437484

  8. ECG Changes in Young Healthy Smokers: A Simple and Cost-Effective Method to Assess Cardiovascular Risk According to Pack-Years of Smoking.

    PubMed

    Sharma, Nirmal Kumar; Jaiswal, Kapil Kumar; Meena, S R; Chandel, Rahul; Chittora, Saurabh; Goga, Prem Singh; Harish, H B; Sagar, Rajesh

    2017-06-01

    To document the prevalence of ECG abnormalities in young healthy smokers and compare ECG changes in smokers, young healthy non-smokers and amongst smokers with different pack years. This was a prospective case-control study consisting of 200 young healthy male and female individuals, 150 smokers and 50 non-smokers between ages 25-40 years, further categorized and compared according to age, sex and pack years of smoking. The ECG recordings were analyzed for different ECG parameters like heart rate, P-wave duration, P-wave amplitude, PR interval, QRS duration, RR-interval, ST-segment duration, QT interval and QTc interval. The results were compared using statistical tools. In present study abnormalities in ECG parameters were significantly more prevalent in smokers as compared to non-smokers (56.66 % Vs 6.00 %) (p <.0001). Heart rate and QTc-interval increased with increase in the number of pack-years. This increase was reflected more in female with a similar number of pack years. P-wave amplitude tended to increase with increase in the number of pack years more so in males. P-wave duration, PR-interval, QRS-duration and RR-interval tended to decrease with increase in the number of pack years more so in females with similar number of pack years. QT-interval and ST-segment duration tended to decrease with increase in the number of pack years more so in males. ECG abnormalities in this study indicate cardiovascular risk in term of cardiac arrhythmia, pulmonary arterial hypertension, heart blocks etc in such subjects. As this procedure is non-invasive and cost effective it is potentially an effective and yet a simple method for cardiovascular risk evaluation in smokers. Furthermore, such ECG abnormalities may guide the clinician for risk evaluation in smokers and may be used to convince the smokers to quit smoking.

  9. Cardiac Repolarization Abnormalities and Potential Evidence for Loss of Cardiac Sodium Currents on ECGs of Patients with Chagas' Heart Disease

    NASA Technical Reports Server (NTRS)

    Schlegel, T. T.; Medina, R.; Jugo, D.; Nunez, T. J.; Borrego, A.; Arellano, E.; Arenare, B.; DePalma, J. L.; Greco, E. C.; Starc, V.

    2007-01-01

    Some individuals with Chagas disease develop right precordial lead ST segment elevation in response to an ajmaline challenge test, and the prevalence of right bundle branch block (RBBB) is also high in Chagas disease. Because these same electrocardiographic abnormalities occur in the Brugada syndrome, which involves genetically defective cardiac sodium channels, acquired damage to cardiac sodium channels may also occur in Chagas disease. We studied several conventional and advanced resting 12-lead/derived Frank-lead ECG parameters in 34 patients with Chagas -related heart disease (mean age 39 14 years) and in 34 age-/gender-matched healthy controls. All ECG recordings were of 5-10 min duration, obtained in the supine position using high fidelity hardware/software (CardioSoft, Houston, TX). Even after excluding those Chagas patients who had resting BBBs, tachycardia and/or pathologic arrhythmia (n=8), significant differences remained in multiple conventional and advanced ECG parameters between the Chagas and control groups (n=26/group), especially in their respective QT interval variability indices, maximal spatial QRS-T angles and low frequency HRV powers (p=0.0006, p=0.0015 and p=0.0314 respectively). In relation to the issue of potential damage to cardiac sodium channels, the Chagas patients had: 1) greater than or equal to twice the incidence of resting ST segment elevation in leads V1-V3 (n=10/26 vs. n=5/26) and of both leftward (n=5/26 versus n=0/26) and rightward (n=7/26 versus n=3/26) QRS axis deviation than controls; 2) significantly increased filtered (40-250 Hz) QRS interval durations (92.1 8.5 versus 85.3 plus or minus 9.0 ms, p=0.022) versus controls; and 3) significantly decreased QT and especially JT interval durations versus controls (QT interval: 387.5 plus or minus 26.4 versus 408.9 plus or minus 34.6 ms, p=0.013; JT interval: 290.5 plus or minus 26.3 versus 314.8 plus or minus 31.3 ms; p=0.0029). Heart rates and Bazett-corrected QTc/JTc intervals

  10. Differentiating Electromechanical From Non-Electrical Substrates of Mechanical Discoordination to Identify Responders to Cardiac Resynchronization Therapy.

    PubMed

    Lumens, Joost; Tayal, Bhupendar; Walmsley, John; Delgado-Montero, Antonia; Huntjens, Peter R; Schwartzman, David; Althouse, Andrew D; Delhaas, Tammo; Prinzen, Frits W; Gorcsan, John

    2015-09-01

    Left ventricular (LV) mechanical discoordination, often referred to as dyssynchrony, is often observed in patients with heart failure regardless of QRS duration. We hypothesized that different myocardial substrates for LV mechanical discoordination exist from (1) electromechanical activation delay, (2) regional differences in contractility, or (3) regional scar and that we could differentiate electromechanical substrates responsive to cardiac resynchronization therapy (CRT) from unresponsive non-electrical substrates. First, we used computer simulations to characterize mechanical discoordination patterns arising from electromechanical and non-electrical substrates and accordingly devise the novel systolic stretch index (SSI), as the sum of posterolateral systolic prestretch and septal systolic rebound stretch. Second, 191 patients with heart failure (QRS duration ≥120 ms; LV ejection fraction ≤35%) had baseline SSI quantified by automated echocardiographic radial strain analysis. Patients with SSI≥9.7% had significantly less heart failure hospitalizations or deaths 2 years after CRT (hazard ratio, 0.32; 95% confidence interval, 0.19-0.53; P<0.001) and less deaths, transplants, or LV assist devices (hazard ratio, 0.28; 95% confidence interval, 0.15-0.55; P<0.001). Furthermore, in a subgroup of 113 patients with intermediate electrocardiographic criteria (QRS duration of 120-149 ms or non-left bundle branch block), SSI≥9.7% was independently associated with significantly less heart failure hospitalizations or deaths (hazard ratio, 0.41; 95% confidence interval, 0.23-0.79; P=0.004) and less deaths, transplants, or LV assist devices (hazard ratio, 0.27; 95% confidence interval, 0.12-0.60; P=0.001). Computer simulations differentiated patterns of LV mechanical discoordination caused by electromechanical substrates responsive to CRT from those related to regional hypocontractility or scar unresponsive to CRT. The novel SSI identified patients who benefited more

  11. Functional characteristics of left ventricular synchronization via right ventricular outflow-tract pacing detected by two-dimensional strain echocardiography.

    PubMed

    Hirayama, Yasutaka; Kawamura, Yuichiro; Sato, Nobuyuki; Saito, Tatsuya; Tanaka, Hideichi; Saijo, Yasuaki; Kikuchi, Kenjiro; Ohori, Katsumi; Hasebe, Naoyuki

    2017-02-01

    Recently, due to the detrimental effects on the ventricular function associated with right ventricular apical (RVA) pacing, right ventricular septal (RVS) pacing has become the preferred pacing method. However, the term RVS pacing refers to both right ventricular outflow-tract (RVOT) and mid-septal (RVMS) pacing, leading to a misinterpretation of the results of clinical studies. The purpose of this study, therefore, was to elucidate the functional differences of RVA, RVOT, and RVMS pacing in patients with atrioventricular block. We compared the QRS duration, global longitudinal strain (GLS), and left ventricular (LV) synchronization parameters at the three pacing sites in 47 patients. The peak systolic strain (PSS) time delay between the earliest and latest segments among the 18 LV segments and standard deviation (SD) of the time to the PSS were also calculated for the 18 LV segments at each pacing site using two-dimensional (2D) strain echocardiography. RVMS pacing was associated with a significantly shorter QRS duration compared with RVA and RVOT pacing (154.4±21.4 vs 186.5±19.9 and 171.1±21.5 ms, P <0.001). In contrast, RVOT pacing revealed a greater GLS (-14.69±4.92 vs -13.12±4.76 and -13.51±4.81%, P <0.001), shorter PSS time delay between the earliest and latest segments (236.0±87.9 vs 271.3±102.9 and 281.9±126.6%, P =0.007), and shorter SD of the time to the PSS (70.8±23.8 vs 82.7±30.8 and 81.5±33.7 ms, P =0.002) compared with RVA and RVMS pacing. These results suggest that the functional characteristics of RVOT pacing may be a more optimal pacing site than RVMS, regardless of the pacing QRS duration, in patients with atrioventricular conduction disorders.

  12. Changes in parameters of right ventricular function with cardiac resynchronization therapy.

    PubMed

    Sharma, Abhishek; Lavie, Carl J; Vallakati, Ajay; Garg, Akash; Goel, Sunny; Lazar, Jason; Fonarow, Gregg C

    2017-11-01

    Studies have shown that cardiac resynchronization therapy (CRT) significantly improves right ventricle (RV) size and function in patients with heart failure (HF). CRT does not lead to improvement in RV function independent of baseline clinical variables. A systematic search of studies published between 1966 to August 31, 2015 was conducted using Pub Med, CINAHL, Cochrane CENTRAL and the Web of Science databases. Studies reporting tricuspid annular plane systolic excursion (TAPSE) or RV basal strain or RV long axis diameter or RV short axis diameter or RV fractional area change (FAC), before and after CRT, were identified. A meta-analysis was performed using random effects with inverse variance method to determine the pooled mean difference in various parameters of RV function after CRT. Meta-regression analysis was performed to test the relationship between change in various parameters of RV functions after CRT and covariates- age, QRS duration, and left ventricular ejection fraction (LVEF). Thirteen studies (N=1541) were selected for final analysis. CRT therapy led to statistically significant increases in TAPSE [1.21 (95% CI 0.55-1.86; p<0.001)], RV FAC [2.26 (95% CI 0.50-4.01; p<0.001)] and basal strain [2.82 (95% CI 0.59-5.05; p<0.001)] and statistically significant decreases in mean RV long axis diameter [-2.94 (95% CI -5.07- -0.82; p=0.005)] and short axis diameter [-1.39 (95% CI -2.10- -0.67; p=0.876)] after a mean follow up period of 9 months. However, after meta-regression analysis for age, QRS duration, and baseline LVEF as covariates, there was no significant improvement in any of the parameters of RV function after CRT. There was a statistically significant improvement in TAPSE, RV basal strain, RV fractional area, RV long axis and short axis with CRT. However, improvement in these echocardiographic parameters of RV function after CRT was not independent of baseline clinical variables but statistically dependent on age, QRS duration and baseline LVEF.

  13. Association of apical rocking with long-term major adverse cardiac events in patients undergoing cardiac resynchronization therapy.

    PubMed

    Ghani, Abdul; Delnoy, Peter Paul H M; Ottervanger, Jan Paul; Ramdat Misier, Anand R; Smit, Jaap Jan J; Adiyaman, Ahmet; Elvan, Arif

    2016-02-01

    Correctly identifying patients who will benefit from cardiac resynchronization therapy (CRT) is still challenging. 'Apical rocking' is observed in asynchronously contracting ventricles and is associated with echocardiographic response to CRT. The association of apical rocking and long-term clinical outcome is however unknown at present. We assessed the predictive value of left ventricular (LV) apical rocking on a long-term clinical outcome in patients treated with CRT. Consecutive heart failure patients treated with primary indication for CRT-D between 2005 and 2009 were included in a prospective registry. Echocardiography was performed prior to CRT to assess apical rocking, defined as motion of the LV apical myocardium perpendicular to the LV long axis. Major adverse cardiac event (MACE) was defined as combined end point of cardiac death and/or heart failure hospitalization and/or appropriate therapy (ATP and/or ICD shocks). All echocardiograms were assessed by independent cardiologists, blinded for clinical data. Multivariable analyses were performed to adjust for potential confounders. Two hundred and ninety-five patients with echocardiography prior to implantation were included in the final analyses. Apical rocking was present in 45% of the study patients. Apical rocking was significantly more common in younger patients, females, patients with sinus rhythm, non-ischaemic cardiomyopathy, and in patients with LBBB and wider QRS duration. During a mean clinical follow-up of 5.2 ± 1.6 years, 92 (31%) patients reached the end point of the study (MACE). Patients with MACE had shorter QRS duration, had more ischaemic cardiomyopathy, and were more often on Amiodarone. In univariate analyses, MACE was associated with shorter QRS duration, ischaemic aetiology, and the absence of apical rocking. After multivariable analyses, apical rocking was associated with less MACE (hazards ratio, HR 0.44, 95% confidence interval, CI 0.25-0.77). Apical rocking is an independent

  14. T wave alternans threshold late after repair of tetralogy of Fallot

    NASA Technical Reports Server (NTRS)

    Cheung, Michael M H.; Weintraub, Robert G.; Cohen, Richard J.; Karl, Tom R.; Wilkinson, James L.; Davis, Andrew M.

    2002-01-01

    INTRODUCTION: Sustained microvolt-level T wave alternans (TWA) is a marker of increased risk for malignant ventricular arrhythmia. There is a significant risk of arrhythmia and sudden death after repair of congenital heart disease. The aim of this study was to determine the prevalence and characteristics of TWA after repair of tetralogy of Fallot (TOF). METHODS AND RESULTS: TWA was evaluated during bicycle exercise in 49 subjects who had consecutively undergone transatrial-transpulmonary repair. Median values for age, age at repair, and follow-up duration were 14.9 years (11.5-20.8), 1.6 years (0.2-4.9), and 11.6 years (9.4-17.2), respectively. All patients were in New York Heart Association functional class I and were asymptomatic. Median QRS duration was 120 msec (80-150). Sustained TWA was detected in 7 (23%) of 31 subjects with adequate tests. In these 7 subjects, median onset heart rate (HR) was 120 (98-155). Median HR threshold as a percentage of predicted maximum HR (220 - age) was 58% (48-77). Sustained TWA prevalence was not significantly different compared with normal subjects (7/31 vs 9/83; P = 0.1). Onset HR in the TOF group was significantly lower [mean (SD) of 122 (20) vs 139 (12), P < 0.05]. In the TOF group with sustained TWA, the TWA occurred in 4 of 7 at <60% predicted maximum HR versus 1 of 9 normal subjects (P < 0.05); 3 of 7 had onset HR <120 versus 0 of 9 normal subjects (P < 0.03). There was no significant difference in age, gender, transannular patch use, restrictive right ventricular physiology, QRS duration, QTc, QT/QRS dispersion, or nonsustained ventricular tachycardia in subjects with or those without sustained TWA. CONCLUSION: The onset HR for sustained TWA is significantly lower after repair of TOF. Further study is required to determine whether this represents an increased risk for arrhythmia in this patient group.

  15. Ventricular dysfunction in type 1 myotonic dystrophy: electrical, mechanical, or both?

    PubMed

    Lindqvist, P; Mörner, S; Olofsson, B O; Backman, C; Lundblad, D; Forsberg, H; Henein, M Y

    2010-09-03

    Myotonic dystrophy type 1 (DM1) is a systemic disease which affects the heart and may be a cause of sudden death. Conduction disturbances are the major cardiac abnormalities seen in this condition. We sought to assess electrical and mechanical cardiac functions to identify abnormalities that might explain sudden cardiac death in DM1. Thirty six patients with DM1 and 16 controls were studied using echocardiography including myocardial Doppler. ECG recordings were also obtained. Left ventricular (LV) dimensions were maintained but systolic function was reduced (p<0.001), including stroke volume (p<0.05). LV segmental myocardial isovolumic contraction time was prolonged (p<0.001) and correlated with PR interval (p<0.001). Isovolumic relaxation time was prolonged (p<0.05) and filling time was reduced (p<0.001). LV cavity was significantly asynchronous demonstrated by prolonged total isovolumic time (t-IVT) (p<0.001), high Tei index (p<0.001) and low ejection index (p<0.001). Right ventricular (RV) strain was reduced (p<0.001) as were its systolic and diastolic velocities (p<0.05 for both). 22/36 patients had prolonged LV t-IVT>12.3 s/min (upper 95% normal CI), 13 of whom had PR≥200 ms, 11 had QRS duration>120 ms (5 had combined abnormality) and the remaining 5 had neither. Over the 3 years follow up 10 patients had events, 6 of them cardiac. t-IVT was prolonged in 5/6 patients, PR interval in 4 and QRS duration in one. In DM1 patients, LV conventional measurements are modestly impaired but cardiac time relations suggest marked asynchronous cavity function. Although our findings were primarily explained on the basis of long PR interval or broad QRS duration a minority presented an evidence for myocardial cause of asynchrony rather than electrical. Early identification of such abnormalities may guide towards a need for additional electrical resynchronization therapy which may improve survival in a way similar to what has been shown in heart failure trials. Copyright

  16. Prognostic Estimation of Advanced Heart Failure With Low Left Ventricular Ejection Fraction and Wide QRS Interval.

    PubMed

    Oh, Changmyung; Chang, Hyuk-Jae; Sung, Ji Min; Kim, Ji Ye; Yang, Wooin; Shim, Jiyoung; Kang, Seok-Min; Ha, Jongwon; Rim, Se-Joong; Chung, Namsik

    2012-10-01

    Cardiac resynchronization therapy (CRT) has been known to improve the outcome of advanced heart failure (HF) but is still underutilized in clinical practice. We investigated the prognosis of patients with advanced HF who were suitable for CRT but were treated with conventional strategies. We also developed a risk model to predict mortality to improve the facilitation of CRT. Patients with symptomatic HF with left ventricular ejection fraction ≤35% and QRS interval >120 ms were consecutively enrolled at cardiovascular hospital. After excluding those patients who had received device therapy, 239 patients (160 males, mean 67±11 years) were eventually recruited. During a follow-up of 308±236 days, 56 (23%) patients died. Prior stroke, heart rate >90 bpm, serum Na ≤135 mEq/L, and serum creatinine ≥1.5 mg/dL were identified as independent factors using Cox proportional hazards regression. Based on the risk model, points were assigned to each of the risk factors proportional to the regression coefficient, and patients were stratified into three risk groups: low- (0), intermediate-(1-5), and high-risk (>5 points). The 2-year mortality rates of each risk group were 5, 31, and 64 percent, respectively. The C statistic of the risk model was 0.78, and the model was validated in a cohort from a different institution where the C statistic was 0.80. The mortality of patients with advanced HF who were managed conventionally was effectively stratified using a risk model. It may be useful for clinicians to be more proactive about adopting CRT to improve patient prognosis.

  17. Comparison of standard and Lewis ECG in detection of atrioventricular dissociation in patients with wide QRS tachycardia.

    PubMed

    Aksu, Uğur; Kalkan, Kamuran; Gülcü, Oktay; Topcu, Selim; Sevimli, Serdar; Aksakal, Enbiya; Ipek, Emrah; Açıkel, Mahmut; Tanboğa, Ibrahim Halil

    2016-12-15

    The atrioventricular (AV) dissociation, which is frequently used in differential diagnosis of wide QRS complex tachycardia (WQCT), is the most specific finding of ventricular tachycardia (VT) with lower sensitivity. Herein, we aimed to show the importance of Lewis lead ECG records to detect 'visible p waves' during WQCT. A total of 21 consecutive patients who underwent electrophysiologic study (EPS) were included in the study. During EPS, by using a quadripolar diagnostic catheter directed to the right ventricular apex, a fixed stimulus was given and the ventriculoatrial (VA) Wenkebach point was found, and a VT was simulated by a RV apical stimulus at 300ms. The standard and Lewis lead ECG records were taken during this procedure. We detected 'visible p waves' in 7 (33.3%) and 14 (66.7%) patients in the standard and Lewis lead ECG groups, respectively. In terms of the 'visible p waves', there was a statistically significant difference between groups (p=0.022). The sensitivity of standard and Lewis lead ECG in determination of the visible p waves was 33.3% and 66.7%, respectively. The Lewis lead ECG can be more informative about AV dissociation than the standard 12 lead ECG. As a result, we could suggest the assessment of the Lewis lead ECG recording in addition to the standard 12 lead ECG in differential diagnosis of VT in patients with WQCT. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Preoperative Electrocardiogram Score for Predicting New-Onset Postoperative Atrial Fibrillation in Patients Undergoing Cardiac Surgery.

    PubMed

    Gu, Jiwei; Andreasen, Jan J; Melgaard, Jacob; Lundbye-Christensen, Søren; Hansen, John; Schmidt, Erik B; Thorsteinsson, Kristinn; Graff, Claus

    2017-02-01

    To investigate if electrocardiogram (ECG) markers from routine preoperative ECGs can be used in combination with clinical data to predict new-onset postoperative atrial fibrillation (POAF) following cardiac surgery. Retrospective observational case-control study. Single-center university hospital. One hundred consecutive adult patients (50 POAF, 50 without POAF) who underwent coronary artery bypass grafting, valve surgery, or combinations. Retrospective review of medical records and registration of POAF. Clinical data and demographics were retrieved from the Western Denmark Heart Registry and patient records. Paper tracings of preoperative ECGs were collected from patient records, and ECG measurements were read by two independent readers blinded to outcome. A subset of four clinical variables (age, gender, body mass index, and type of surgery) were selected to form a multivariate clinical prediction model for POAF and five ECG variables (QRS duration, PR interval, P-wave duration, left atrial enlargement, and left ventricular hypertrophy) were used in a multivariate ECG model. Adding ECG variables to the clinical prediction model significantly improved the area under the receiver operating characteristic curve from 0.54 to 0.67 (with cross-validation). The best predictive model for POAF was a combined clinical and ECG model with the following four variables: age, PR-interval, QRS duration, and left atrial enlargement. ECG markers obtained from a routine preoperative ECG may be helpful in predicting new-onset POAF in patients undergoing cardiac surgery. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Word Durations in Non-Native English

    PubMed Central

    Baker, Rachel E.; Baese-Berk, Melissa; Bonnasse-Gahot, Laurent; Kim, Midam; Van Engen, Kristin J.; Bradlow, Ann R.

    2010-01-01

    In this study, we compare the effects of English lexical features on word duration for native and non-native English speakers and for non-native speakers with different L1s and a range of L2 experience. We also examine whether non-native word durations lead to judgments of a stronger foreign accent. We measured word durations in English paragraphs read by 12 American English (AE), 20 Korean, and 20 Chinese speakers. We also had AE listeners rate the `accentedness' of these non-native speakers. AE speech had shorter durations, greater within-speaker word duration variance, greater reduction of function words, and less between-speaker variance than non-native speech. However, both AE and non-native speakers showed sensitivity to lexical predictability by reducing second mentions and high frequency words. Non-native speakers with more native-like word durations, greater within-speaker word duration variance, and greater function word reduction were perceived as less accented. Overall, these findings identify word duration as an important and complex feature of foreign-accented English. PMID:21516172

  20. Mechanical dyssynchrony is additive to ECG criteria and independently associated with reverse remodelling and clinical response to cardiac resynchronisation therapy in patients with advanced heart failure

    PubMed Central

    Bank, Alan J; Gage, Ryan M; Marek, Josef J; Onishi, Toshinari; Burns, Kevin V; Schwartzman, David; Saba, Samir; Gorcsan, John

    2015-01-01

    Background QRS duration and morphology are known established predictors of cardiac resynchronisation therapy (CRT) response, whereas mechanical dyssynchrony is not. Our aim was to determine if mechanical dyssynchrony provides independent prognostic information on CRT response. Methods We studied 369 consecutive patients with heart failure (HF) with low ejection fraction (EF) and widened QRS receiving CRT. Radial dyssynchrony (septal-posterior radial peak strain delay ≥130 ms by speckle tracking) assessment was possible in 318 patients (86%). Associations with left ventricular end-systolic volume (LVESV) changes were examined using linear regression, and clinical outcomes analysed using Cox regression adjusted for multiple established outcome correlates. Results Patients with radial dyssynchrony before CRT (64%) had greater improvements in EF (8.8±9.4 vs 6.1±9.7 units, p=0.04) and LVESV (−30±41 vs −10±30 mL, p<0.01). Radial dyssynchrony was independently associated with reduction in LVESV (regression coefficient −10.5 mL, 95% CI −20.5 to −0.5, p=0.040) as was left bundle-branch block (−17.7 mL, −27.6 to −7.7, p=0.001). Patients with radial dyssynchrony had a 46% lower incidence of death, transplant or implantation of a left ventricular assist device (adjusted HR 0.54, 95% CI 0.31 to 0.92, p=0.02) and a 39% lower incidence of death or HF hospitalisation (0.61, 0.40 to 0.93, p=0.02) over 2 years. Conclusions Radial dyssynchrony was associated with significant improvements in LVESV and clinical outcomes following CRT and is independent of QRS duration or morphology, and additive to current ECG selection criteria to predict response to CRT. PMID:25973213

  1. Prevalence and clinical significance of left bundle branch block according to classical or strict definition criteria in permanent pacemaker patients.

    PubMed

    Mazza, Andrea; Bendini, Maria Grazia; De Cristofaro, Raffaele; Lovecchio, Mariolina; Valsecchi, Sergio; Leggio, Massimo; Boriani, Giuseppe

    2017-06-01

    Previous studies have shown that the presence of left bundle branch block (LBBB) is associated with an increased risk of cardiac mortality and heart failure (HF). Recently, new criteria to define strict LBBB have been proposed: QRS duration ≥140 ms for men and ≥130 ms for women, along with mid-QRS notching or slurring in ≥2 contiguous leads. We assessed the prevalence and prognostic significance of LBBB according to classical (QRS duration ≥120ms) and strict criteria in permanent pacemaker patients. We retrospectively enrolled 723 consecutive patients who had undergone single- or dual-chamber pacemaker implantation at the study center from July 2002 to December 2014. Patients with a left ventricular ejection fraction ≤35% or a prior diagnosis of HF were excluded. LBBB was reported in 54 (7%) patients, and strict-LBBB in 15 (2%) patients. During a median follow-up of 48 months (range, 18-92 months), 147 (20%) patients reached the combined endpoint of death or HF hospitalization. Patients with LBBB and those with strict-LBBB displayed significantly higher rates of death or HF hospitalization (log-rank test, all P < 0.0001). In particular, strict-LBBB was associated with the worst outcome. The presence of LBBB according to classical definition criteria (hazard ratio [HR] = 1.98, confidence interval [CI]: 1.23-3.19, P = 0.005) and to strict criteria (HR = 2.20; CI: 1.04-4.65; P = 0.039) were both confirmed as independent predictors of death or HF hospitalization after adjustment for relevant clinical covariates. Among patients who had undergone standard pacemaker implantation, the prevalence of LBBB was 7% according to classical definition criteria and 2% according to strict criteria. The presence of LBBB, and particularly of strict-LBBB, at the baseline predicted a poor outcome in terms of death or HF hospitalization. © 2017 Wiley Periodicals, Inc.

  2. Protective effects of Hawthorn (Crataegus oxyacantha) extract against digoxin-induced arrhythmias in rats.

    PubMed

    Alp, Hayrullah; Soner, Burak Cem; Baysal, Tamer; Şahin, Ayşe Saide

    2015-01-01

    Digitalis preparations are commonly used by children and adults with heart diseases worldwide, although excessive doses may cause cardiac effects. The aim of the study is to evaluate the antiarrhythmic effect of Crataegus oxyacantha extract on digoxin-induced arrhythmias in anesthetized Wistar rats. Control and experimental groups were evaluated for arrhythmias induced by digoxin. Fifteen rats (7 as controls and 8 as the experimental group) were included in the study. The dry fruits of 100 mg Crataegus oxyacantha were extracted by percolation method. Digoxin, at a dose of 40 µg/kg/min, was infused to form the arrhythmias in all rats. Simultaneously, the extract was infused into the experimental group, while 0.9% NaCl was infused into control group. Electrocardiographic QRS prolongation and arterial blood pressure changes were analyzed. The experimental group lived longer (62.13±2.20 min) than the controls (p=0.002). On the other hand, the time to beginning of QRS prolongation did not differ between the two groups (p=0.812). Bradycardia was significant in the control group (288.01±10.54 beat/min and p=0.01). The maximum QRS duration was observed in the control group during the digoxin and 0.9% NaCl infusion period (53.29±3.99 ms and p=0.001). Also, the durations of atrial and ventricular arrhythmias were shorter in the experimental group. However, arterial blood pressure dipping was significant in the experimental group (23.67±10.89 mm Hg and p<0.001). Crataegus oxyacantha alcoholic extract produced an antiarrhythmic effect that was induced by digoxin in Wistar rats. However, in the clinical use of this extract, the hypotensive effect should be considered. Also, the alcoholic extract of Crataegus oxyacantha may be an alternative treatment medication for arrhythmias induced by digoxin toxicity in humans.

  3. Protective effects of Hawthorn (Crataegus oxyacantha) extract against digoxin-induced arrhythmias in rats

    PubMed Central

    Alp, Hayrullah; Soner, Burak Cem; Baysal, Tamer; Şahin, Ayşe Saide

    2016-01-01

    Objective: Digitalis preparations are commonly used by children and adults with heart diseases worldwide, although excessive doses may cause cardiac effects. The aim of the study is to evaluate the antiarrhythmic effect of Crataegus oxyacantha extract on digoxin-induced arrhythmias in anesthetized Wistar rats. Methods: Control and experimental groups were evaluated for arrhythmias induced by digoxin. Fifteen rats (7 as controls and 8 as the experimental group) were included in the study. The dry fruits of 100 mg Crataegus oxyacantha were extracted by percolation method. Digoxin, at a dose of 40 μg/kg/min, was infused to form the arrhythmias in all rats. Simultaneously, the extract was infused into the experimental group, while 0.9% NaCl was infused into control group. Electrocardiographic QRS prolongation and arterial blood pressure changes were analyzed. Results: The experimental group lived longer (62.13±2.20 min) than the controls (p=0.002). On the other hand, the time to beginning of QRS prolongation did not differ between the two groups (p=0.812). Bradycardia was significant in the control group (288.01±10.54 beat/min and p=0.01). The maximum QRS duration was observed in the control group during the digoxin and 0.9% NaCl infusion period (53.29±3.99 ms and p=0.001). Also, the durations of atrial and ventricular arrhythmias were shorter in the experimental group. However, arterial blood pressure dipping was significant in the experimental group (23.67±10.89 mm Hg and p<0.001). Conclusion: Crataegus oxyacantha alcoholic extract produced an antiarrhythmic effect that was induced by digoxin in Wistar rats. However, in the clinical use of this extract, the hypotensive effect should be considered. Also, the alcoholic extract of Crataegus oxyacantha may be an alternative treatment medication for arrhythmias induced by digoxin toxicity in humans. PMID:25880053

  4. Gender differences in the electrocardiogram screening of athletes.

    PubMed

    Bessem, Bram B; de Bruijn, Matthijs M C; Nieuwland, Wybe W

    2017-02-01

    Gender-related differences are frequently used in medicine. Electrocardiograms are also subject to such differences. This study evaluated gender differences in ECG parameters of young athletes, discussing the possible implications of these differences for ECG criteria used in the cardiovascular screening of young athletes. Observational cross-sectional study. In 2013 and 2014 all the ECGs from the cardiovascular screenings performed at University Sports Medical Centre in Groningen of the student athletes who wanted to participate in a college sports program were collected. The ECG characteristics were scored using computer-based measurements and the Seattle ECG criteria. The study population included 1436 athletes, of which 72% were male. Male athletes were older (19.3 years vs. 18.6 years), participated in sports more frequently (4.0/week vs. 3.8/week) and spent more hours per week practising sports (6.4h/week vs. 5.8h/week) than female athletes. Male athletes had significantly higher PR intervals (149ms vs. 141ms), lead voltages and QRS duration (98ms vs. 88ms). Female athletes had significantly higher resting heart rates (69/min vs. 64/min) and QTc intervals (407ms vs. 400ms). Male athletes also had significantly higher amounts of sinus bradycardia (38.3% vs. 23.0%), incomplete RBBB (15.0% vs. 3.7%), early repolarisation (4.5% vs. 1.0%) and isolated QRS voltage criteria for LVH (26.3% vs. 4.6%). All P-values were ≤0.001. ECGs of young athletes demonstrate gender-related differences. These differences could be considered in their cardiovascular screening. For the Seattle ECG criteria we advise additional research into the clinical implications of using gender-based cut-off values for the QRS duration in the intraventricular conduction delay criterion. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  5. Electocardiographic findings in adult Nigerians with sickle cell anaemia.

    PubMed

    Oguanobi, N I; Onwubere, B J C; Ike, S O; Anisiuba, B C; Ejim, E C; Ibegbulam, O G

    2010-09-01

    Cardiovascular system abnormalities are common causes of morbidity and mortality in sickle cell anaemia. The study aims at determining the pattern of electrocardiographic changes in adult Nigerian sickle cell anaemia patients. A descriptive cross sectional study was done on sixty sickle cell anaemia patients seen at the adult sickle cell clinic of University of Nigeria Teaching Hospital (UNTH) Enugu, and sixty age and sex matched normal controls. All the subjects had clinical evaluation as well as electrocardiographic examination. The mean heart rate, P-wave duration, P-wave dispersion, PR interval, QRS duration, QRS dispersion, QTc interval and QTc dispersion were significantly higher in the patients than in the control group. Electrocardiographic abnormalities identified by this study were: left ventricular hypertrophy (75%; 1.7%), left atrial enlargement (40%; 0%), biventricular hypertrophy (11%; 0), ST-segment elevation (10%; 0%) and increased P-wave and QTc dispersions. ST segment elevation was found more in patients with moderate and severe anaemia (P= 0.02, Spearman correlation r= 0.342; P= 0.007), Sickle cell anaemia is associated with significant electrocardiographic abnormalities. Further prospective studies are recommended to evaluate the prognostic significance of the electrocardiographic intervals dispersion on the long term disease outcome in sickle cell anaemia.

  6. Icon Duration and Development.

    ERIC Educational Resources Information Center

    Gummerman, Kent; And Others

    In this study, developmental changes in duration of the icon (visual sensory store) were investigated with three converging tachistoscopic tasks. (1) Stimulus interuption detection (SID), a variation of the two-flash threshold method, was performed by 29 first- and 32 fifth-graders, and 32 undergraduates. Icon duration was estimated by stimulus…

  7. 32 CFR 2001.12 - Duration of classification.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 6 2013-07-01 2013-07-01 false Duration of classification. 2001.12 Section 2001... Classification § 2001.12 Duration of classification. (a) Determining duration of classification for information originally classified under the Order—(1) Establishing duration of classification. Except for information...

  8. 32 CFR 2001.12 - Duration of classification.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 6 2014-07-01 2014-07-01 false Duration of classification. 2001.12 Section 2001... Classification § 2001.12 Duration of classification. (a) Determining duration of classification for information originally classified under the Order—(1) Establishing duration of classification. Except for information...

  9. 32 CFR 2001.12 - Duration of classification.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 6 2012-07-01 2012-07-01 false Duration of classification. 2001.12 Section 2001... Classification § 2001.12 Duration of classification. (a) Determining duration of classification for information originally classified under the Order—(1) Establishing duration of classification. Except for information...

  10. Incorporating Duration Information in Activity Recognition

    NASA Astrophysics Data System (ADS)

    Chaurasia, Priyanka; Scotney, Bryan; McClean, Sally; Zhang, Shuai; Nugent, Chris

    Activity recognition has become a key issue in smart home environments. The problem involves learning high level activities from low level sensor data. Activity recognition can depend on several variables; one such variable is duration of engagement with sensorised items or duration of intervals between sensor activations that can provide useful information about personal behaviour. In this paper a probabilistic learning algorithm is proposed that incorporates episode, time and duration information to determine inhabitant identity and the activity being undertaken from low level sensor data. Our results verify that incorporating duration information consistently improves the accuracy.

  11. Association between Latest Activated Sites in the Left Ventricle and Akinetic Segments in Patients with Ischemic Cardiomyopathy.

    PubMed

    Sadeghian, Hakimeh; Kousari, Aliasghar; Majidi, Shahla; Rezvanfard, Mehrnaz; Kazemisaeid, Ali; Moezzi, Seyed Ali; Vasheghani Farahani, Ali; Abdar Esfahani, Morteza; Sahebjam, Mohammad; Zoroufian, Arezoo; Sadeghian, Afsaneh

    2016-07-06

    Background: It is not clear whether the latest activation sites in the left ventricle (LV) are matched with infracted regions in patients with ischemic cardiomyopathy (ICM). We aimed to investigate whether the latest activation sites in the LV are in agreement with the region of akinesia in patients with ICM. Methods: Data were analyzed in 106 patients (age = 60.5 ± 12.1 y, male = 88.7%) with ICM (ejection fraction ≤ 35%) who were refractory to pharmacological therapy and were referred to the echocardiography department for an evaluation of the feasibility of cardiac resynchronization therapy. Wall motion abnormalities, time to peak systolic myocardial velocity (Ts) of 6 basal and 6 mid-portion segments of the LV, and 4 frequently used dyssynchrony indices were measured using 2-dimensional echocardiography and tissue Doppler imaging (TDI). To evaluate the influence of the electrocardiographic pattern, we categorized the patients into 2 groups: patients with QRS ≤ 120 ms and those with QRS >120 ms. Results: A total of 1 272 segments were studied. The latest activation sites (with longest Ts) were most frequently located in the mid-anterior (n = 32, 30.2%) and basal-anterior segments (n = 29, 27.4%), while the most common sites of akinesia were the mid-anteroseptal (n = 65, 61.3%) and mid-septal (n = 51, 48.1%) segments. Generally, no significant concordance was found between the latest activated segments and akinesia either in all the patients or in the QRS groups. Detailed analysis within the segments indicated a good agreement between akinesia and delayed activation in the basal-lateral segment solely in the patients with QRS duration ≤ 120 ms (Φ = 0.707; p value ≤ 0.001). Conclusion: The akinetic segment on 2-dimensional echocardiogram was not matched with the latest activation sites in the LV determined by TDI in patients with ICM.

  12. Association between Latest Activated Sites in the Left Ventricle and Akinetic Segments in Patients with Ischemic Cardiomyopathy

    PubMed Central

    Sadeghian, Hakimeh; Kousari, Aliasghar; Majidi, Shahla; Rezvanfard, Mehrnaz; Kazemisaeid, Ali; Moezzi, Seyed Ali; Vasheghani Farahani, Ali; Abdar Esfahani, Morteza; Sahebjam, Mohammad; Zoroufian, Arezoo; Sadeghian, Afsaneh

    2016-01-01

    Background: It is not clear whether the latest activation sites in the left ventricle (LV) are matched with infracted regions in patients with ischemic cardiomyopathy (ICM). We aimed to investigate whether the latest activation sites in the LV are in agreement with the region of akinesia in patients with ICM. Methods: Data were analyzed in 106 patients (age = 60.5 ± 12.1 y, male = 88.7%) with ICM (ejection fraction ≤ 35%) who were refractory to pharmacological therapy and were referred to the echocardiography department for an evaluation of the feasibility of cardiac resynchronization therapy. Wall motion abnormalities, time to peak systolic myocardial velocity (Ts) of 6 basal and 6 mid-portion segments of the LV, and 4 frequently used dyssynchrony indices were measured using 2-dimensional echocardiography and tissue Doppler imaging (TDI). To evaluate the influence of the electrocardiographic pattern, we categorized the patients into 2 groups: patients with QRS ≤ 120 ms and those with QRS >120 ms. Results: A total of 1 272 segments were studied. The latest activation sites (with longest Ts) were most frequently located in the mid-anterior (n = 32, 30.2%) and basal-anterior segments (n = 29, 27.4%), while the most common sites of akinesia were the mid-anteroseptal (n = 65, 61.3%) and mid-septal (n = 51, 48.1%) segments. Generally, no significant concordance was found between the latest activated segments and akinesia either in all the patients or in the QRS groups. Detailed analysis within the segments indicated a good agreement between akinesia and delayed activation in the basal-lateral segment solely in the patients with QRS duration ≤ 120 ms (Φ = 0.707; p value ≤ 0.001). Conclusion: The akinetic segment on 2-dimensional echocardiogram was not matched with the latest activation sites in the LV determined by TDI in patients with ICM. PMID:27956911

  13. ECG parameters predict left ventricular conduction delay in patients with left ventricular dysfunction.

    PubMed

    Pastore, Gianni; Maines, Massimiliano; Marcantoni, Lina; Zanon, Francesco; Noventa, Franco; Corbucci, Giorgio; Baracca, Enrico; Aggio, Silvio; Picariello, Claudio; Lanza, Daniela; Rigatelli, Gianluca; Carraro, Mauro; Roncon, Loris; Barold, S Serge

    2016-12-01

    Estimating left ventricular electrical delay (Q-LV) from a 12-lead ECG may be important in evaluating cardiac resynchronization therapy (CRT). The purpose of this study was to assess the impact of Q-LV interval on ECG configuration. One hundred ninety-two consecutive patients undergoing CRT implantation were divided electrocardiographically into 3 groups: left bundle branch block (LBBB), right bundle branch block (RBBB), and nonspecific intraventricular conduction delay (IVCD). The IVCD group was further subdivided into 81 patients with left (L)-IVCD and 15 patients with right (R)-IVCD (resembling RBBB, but without S wave in leads I and aVL). The Q-LV interval in the different groups and the relationship between ECG parameters and the maximum Q-LV interval were analyzed. Patients with LBBB presented a long Q-LV interval (147.7 ± 14.6 ms, all exceeding cutoff value of 110 ms), whereas RBBB patients presented a very short Q-LV interval (75.2 ± 16.3 ms, all <110 ms). Patients with an IVCD displayed a wide range of Q-LV intervals. In L-IVCD, mid-QRS notching/slurring showed the strongest correlation with a longer Q-LV interval, followed, in decreasing order, by QRS duration >150 ms and intrinsicoid deflection >60 ms. Isolated mid-QRS notching/slurring predicted Q-LV interval >110 ms in 68% of patients. The R-IVCD group presented an unexpectedly longer Q-LV interval (127.0 ± 12.5 ms; 13/15 patients had Q-LV >110 ms). Patients with LBBB have a very prolonged Q-LV interval. Mid-QRS notching in lateral leads strongly predicts a longer Q-LV interval in L-IVCD patients. Patients with R-IVCD constitute a subgroup of patients with a long Q-LV interval. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  14. 5 CFR 890.1302 - Duration.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 2 2010-01-01 2010-01-01 false Duration. 890.1302 Section 890.1302 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) FEDERAL... Demonstration Project § 890.1302 Duration. The demonstration project will run from January 1, 2000, through...

  15. 14 CFR 21.313 - Duration.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Duration. 21.313 Section 21.313 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT CERTIFICATION PROCEDURES FOR PRODUCTS AND PARTS Approval of Materials, Parts, Processes, and Appliances § 21.313 Duration...

  16. Composition and conductance distributions of single GeSi quantum rings studied by conductive atomic force microscopy combined with selective chemical etching.

    PubMed

    Lv, Y; Cui, J; Jiang, Z M; Yang, X J

    2013-02-15

    Atomic force microscopy imaging combined with selective chemical etching is employed to quantitatively investigate three-dimensional (3D) composition distributions of single GeSi quantum rings (QRs). In addition, the 3D quantitative composition distributions and the corresponding conductance distributions are simultaneously obtained on the same single GeSi QRs by conductive atomic force microscopy combined with selective chemical etching, allowing us to investigate the correlations between the conductance and composition distributions of single QRs. The results show that the QRs' central holes have higher Ge content, but exhibit lower conductance, indicating that the QRs' conductance distribution is not consistent with their composition distribution. By comparing the topography, composition and conductance profiles of the same single QRs before and after different etching processes, it is found that the conductance distributions of GeSi QRs do not vary with the change of composition distribution. Instead, the QRs' conductance distributions are found to be consistent with their topographic shapes, which can be supposed to be due to the shape determined electronic structures.

  17. Duration of surgical-orthodontic treatment.

    PubMed

    Häll, Birgitta; Jämsä, Tapio; Soukka, Tero; Peltomäki, Timo

    2008-10-01

    To study the duration of surgical-orthodontic treatment with special reference to patients' age and the type of tooth movements, i.e. extraction vs. non-extraction and intrusion before or extrusion after surgery to level the curve of Spee. The material consisted files of 37 consecutive surgical-orthodontic patients. The files were reviewed and gender, diagnosis, type of malocclusion, age at the initiation of treatment, duration of treatment, type of tooth movements (extraction vs. non-extraction and levelling of the curve of Spee before or after operation) and type of operation were retrieved. For statistical analyses two sample t-test, Kruskal-Wallis and Spearman rank correlation tests were used. Mean treatment duration of the sample was 26.8 months, of which pre-surgical orthodontics took on average 17.5 months. Patients with extractions as part of the treatment had statistically and clinically significantly longer treatment duration, on average 8 months, than those without extractions. No other studied variable seemed to have an impact on the treatment time. The present small sample size prevents reliable conclusions to be made. However, the findings suggest, and patients should be informed, that extractions included in the treatment plan increase chances of longer duration of surgical-orthodontic treatment.

  18. Duration of orthognathic-surgical treatment.

    PubMed

    Paunonen, Jaakko; Helminen, Mika; Peltomäki, Timo

    2017-07-01

    The objective of this study was to determine the duration of orthognathic-surgical treatment conducted with conventional pre- and post-surgical orthodontic treatment phases. The study material was comprised of the files of 185 consecutive patients treated in Oral and Maxillofacial Unit, Tampere University Hospital, Finland, in 2007-2014. The files were reviewed and the following data was obtained: gender and age of patients, ICD-10 diagnosis, type of malocclusion, duration of pre- and post-surgical orthodontic treatment and type of operation. Total treatment duration (median) from placement of separating rings for banding until fixed orthodontic appliances were removed and retention period started was 31.1 months, of which pre-surgical orthodontics took 24.4 months and postsurgical 6.4 months. Treatment duration (median) was in BSSO was 32.1, LeFort 1 30.1 and bimaxillary osteotomy 29.7 months. Orthodontic extractions were performed in 35 patients (19%). If the orthodontic treatment included tooth extraction, the duration of pre-surgical treatment was on average 10 months longer, which is a statistically highly significant difference (p < .001, linear regression). Tooth extractions (excluding 3rd molars) included in pre-surgical orthodontic treatment prolong treatment time by an average of 8-9 months.

  19. Periodic Fluctuation of Perceived Duration

    PubMed Central

    Shima, Shuhei; Murai, Yuki; Yuasa, Kenichi; Hashimoto, Yuki

    2018-01-01

    In recent years, several studies have reported that the allocation of spatial attention fluctuates periodically. This periodic attention was revealed by measuring behavioral performance as a function of cue-to-target interval in the Posner cueing paradigm. Previous studies reported behavioral oscillations using target detection tasks. Whether the influence of periodic attention extends to cognitively demanding tasks remains unclear. To assess this, we examined the effects of periodic attention on the perception of duration. In the experiment, participants performed a temporal bisection task while a cue was presented with various cue-to-target intervals. Perceived duration fluctuated rhythmically as a function of cue-to-target interval at a group level but not at an individual level when the target was presented on the same side as the attentional cue. The results indicate that the perception of duration is influenced by periodic attention. In other words, periodic attention can influence the performance of cognitively demanding tasks such as the perception of duration. PMID:29755719

  20. Insomnia with objective short sleep duration is associated with longer duration of insomnia in the Freiburg Insomnia Cohort compared to insomnia with normal sleep duration, but not with hypertension

    PubMed Central

    Johann, Anna F.; Hertenstein, Elisabeth; Kyle, Simon D.; Baglioni, Chiara; Feige, Bernd; Nissen, Christoph; McGinness, Alastair J.; Riemann, Dieter; Spiegelhalder, Kai

    2017-01-01

    Study objectives To replicate the association between insomnia with objective short sleep duration and hypertension, type 2 diabetes and duration of insomnia. Design Retrospective case-control study. Setting Department of Psychiatry and Psychotherapy, Medical Center—University of Freiburg. Participants 328 patients with primary insomnia classified according to DSM-IV criteria (125 males, 203 females, 44.3 ± 12.2 years). Interventions N/A Measurements All participants were investigated using polysomnography, blood pressure measurements, and fasting routine laboratory. Results Insomnia patients with short sleep duration (< 6 hours) in the first night of laboratory sleep presented with a longer duration of insomnia compared to those with normal sleep duration (≥ 6 hours) in the first night of laboratory sleep. Insomnia patients who were categorised as short sleepers in either night were not more likely to suffer from hypertension (systolic blood pressure of ≥ 140 mm Hg, diastolic blood pressure of ≥ 90 mm Hg, or a previously established diagnosis). Data analysis showed that insomnia patients with objective short sleep duration were not more likely to suffer from type 2 diabetes (fasting plasma glucose level of ≥ 126 mg/dl, or a previously established diagnosis). However, the diabetes analysis was only based on a very small number of diabetes cases. As a new finding, insomnia patients who were categorised as short sleepers in either night presented with increases in liver enzyme levels. Conclusions The finding on insomnia duration supports the concept of two distinct sub-groups of insomnia, namely insomnia with, and without, objectively determined short sleep duration. However, our data challenges previous findings that insomnia patients with short sleep duration are more likely to suffer from hypertension. PMID:28746413

  1. Insomnia with objective short sleep duration is associated with longer duration of insomnia in the Freiburg Insomnia Cohort compared to insomnia with normal sleep duration, but not with hypertension.

    PubMed

    Johann, Anna F; Hertenstein, Elisabeth; Kyle, Simon D; Baglioni, Chiara; Feige, Bernd; Nissen, Christoph; McGinness, Alastair J; Riemann, Dieter; Spiegelhalder, Kai

    2017-01-01

    To replicate the association between insomnia with objective short sleep duration and hypertension, type 2 diabetes and duration of insomnia. Retrospective case-control study. Department of Psychiatry and Psychotherapy, Medical Center-University of Freiburg. 328 patients with primary insomnia classified according to DSM-IV criteria (125 males, 203 females, 44.3 ± 12.2 years). N/A. All participants were investigated using polysomnography, blood pressure measurements, and fasting routine laboratory. Insomnia patients with short sleep duration (< 6 hours) in the first night of laboratory sleep presented with a longer duration of insomnia compared to those with normal sleep duration (≥ 6 hours) in the first night of laboratory sleep. Insomnia patients who were categorised as short sleepers in either night were not more likely to suffer from hypertension (systolic blood pressure of ≥ 140 mm Hg, diastolic blood pressure of ≥ 90 mm Hg, or a previously established diagnosis). Data analysis showed that insomnia patients with objective short sleep duration were not more likely to suffer from type 2 diabetes (fasting plasma glucose level of ≥ 126 mg/dl, or a previously established diagnosis). However, the diabetes analysis was only based on a very small number of diabetes cases. As a new finding, insomnia patients who were categorised as short sleepers in either night presented with increases in liver enzyme levels. The finding on insomnia duration supports the concept of two distinct sub-groups of insomnia, namely insomnia with, and without, objectively determined short sleep duration. However, our data challenges previous findings that insomnia patients with short sleep duration are more likely to suffer from hypertension.

  2. Response of the ECG to short-term diuresis in patients with heart failure.

    PubMed

    Madias, John E; Song, Jessica; White, C Michael; Kalus, James S; Kluger, Jeffrey

    2005-07-01

    Increase in the amplitude of electrocardiogram (ECG) QRS complexes has been observed in patients treated for heart failure (HF), but the underlying mechanism has not been delineated. Also, correlation of augmentation of the QRS potentials with loss of weight has been noted in patients recovering from anasarca of varying etiology, or after hemodialysis. We assessed the effect of diuresis-based fluid loss in patients treated for HF on the amplitude of ECG QRS complexes. This is a cohort study based on ECG and other data from a previously published investigation of patients with HF conducted at a university affiliated hospital, which used new measurements and analysis, performed by a totally blinded investigator based at another institution. Twenty-one patients (10 men) aged 70.5+/-12.7 years, 13 with ischemic, and 8 with nonischemic cardiomyopathy, were admitted to the hospital for management of exacerbated HF and were observed for 48 hours. The patients received diuresis, and had routine laboratory testing, documentation of the net fluid lost, and recording of ECGs prior to the initiation of therapy and at 24 and 48 hours. Percent change (%Delta) over the course of observation in the sums of the amplitude of QRS complexes from 12 leads (SigmaQRS12), 6-limb leads (SigmaQRS6), and leads 1+2 (SigmaQRS2) in mm of standard ECGs were correlated with net fluid loss corrected for admission weight in mL/kg. Fluid loss amounted to 3204.9+/-1399.5 mL in the course of 40+/-23 hours of diuresis. SigmaQRS12 was 160.9+/-42.3 mm before and 170.0+/-50.7 mm after diuresis (P=0. 024). Percent change in SigmaQRS12, SigmaQRS6, and SigmaQRS2 correlated well with the net fluid loss (r=-0.70, -0.82, -0.61, and P=0.002, 0.0005, 0.001) correspondingly. Changes in sums of the amplitude of QRS complexes of the standard ECG correlates well with net fluid loss in response to short-term diuresis in patients with HF. Change in the SigmaQRS12, SigmaQRS6, and SigmaQRS2 from ECGs before and after

  3. Office and Home Blood Pressures as Determinants of Electrocardiographic Left Ventricular Hypertrophy Among Black Nigerians Compared With White Flemish

    PubMed Central

    Odili, Augustine N; Thijs, Lutgarde; Yang, Wen-Yi; Ogedengbe, John O; Nwegbu, Maxwell M; Jacobs, Lotte; Wei, Fang-Fei; Feng, Ying-Mei; Zhang, Zhen-Yu; Kuznetsova, Tatiana; Nawrot, Tim S; Staessen, Jan A

    2017-01-01

    Abstract BACKGROUND The association of electrocardiographic left ventricular hypertrophy (ECG-LVH) with blood pressure (BP) in Blacks living in sub-Saharan Africa remains poorly documented. METHODS In 225 Black Nigerians and 729 White Flemish, we analyzed QRS voltages and voltage-duration products and 12 criteria diagnostic of ECG-LVH in relation to office BP (mean of 5 consecutive readings) and home BP (duplicate morning and evening readings averaged over 1 week). RESULTS In multivariable analyses, QRS voltage and voltage-duration indexes were generally higher in Blacks than Whites. By using any of 12 criteria, ECG-LVH was more prevalent among Black than White men (54.4% vs. 36.0%) with no ethnic difference among women (17.1%). Precordial voltages and voltage-duration products increased with office and home systolic BP (SBP), and increases were up to 3-fold steeper in Blacks. In Blacks vs. Whites, increases in the Sokolow–Lyon voltage associated with a 10-mm Hg higher SBP were 0.18 mV (95% confidence interval [CI], 0.09–0.26) vs. 0.06 mV (0.02–0.09) and 0.17 mV (0.07–0.28) vs. 0.11 mV (CI, 0.07–0.15) for office and home BP, respectively, with a significant ethnic gradient (P < 0.05). The risk of ECG-LVH increased more with office and home BP in Blacks than Whites. CONCLUSIONS Associations of ECG voltages and voltage-duration products and risk of ECG-LVH with BP are steeper in Black Nigerians compared with a White reference population. In resource-poor settings of sub-Saharan Africa, the ECG in combination with office and home BP is an essential instrument in risk stratification across the entire BP range. PMID:29059302

  4. Office and Home Blood Pressures as Determinants of Electrocardiographic Left Ventricular Hypertrophy Among Black Nigerians Compared With White Flemish.

    PubMed

    Odili, Augustine N; Thijs, Lutgarde; Yang, Wen-Yi; Ogedengbe, John O; Nwegbu, Maxwell M; Jacobs, Lotte; Wei, Fang-Fei; Feng, Ying-Mei; Zhang, Zhen-Yu; Kuznetsova, Tatiana; Nawrot, Tim S; Staessen, Jan A

    2017-11-01

    The association of electrocardiographic left ventricular hypertrophy (ECG-LVH) with blood pressure (BP) in Blacks living in sub-Saharan Africa remains poorly documented. In 225 Black Nigerians and 729 White Flemish, we analyzed QRS voltages and voltage-duration products and 12 criteria diagnostic of ECG-LVH in relation to office BP (mean of 5 consecutive readings) and home BP (duplicate morning and evening readings averaged over 1 week). In multivariable analyses, QRS voltage and voltage-duration indexes were generally higher in Blacks than Whites. By using any of 12 criteria, ECG-LVH was more prevalent among Black than White men (54.4% vs. 36.0%) with no ethnic difference among women (17.1%). Precordial voltages and voltage-duration products increased with office and home systolic BP (SBP), and increases were up to 3-fold steeper in Blacks. In Blacks vs. Whites, increases in the Sokolow-Lyon voltage associated with a 10-mm Hg higher SBP were 0.18 mV (95% confidence interval [CI], 0.09-0.26) vs. 0.06 mV (0.02-0.09) and 0.17 mV (0.07-0.28) vs. 0.11 mV (CI, 0.07-0.15) for office and home BP, respectively, with a significant ethnic gradient (P < 0.05). The risk of ECG-LVH increased more with office and home BP in Blacks than Whites. Associations of ECG voltages and voltage-duration products and risk of ECG-LVH with BP are steeper in Black Nigerians compared with a White reference population. In resource-poor settings of sub-Saharan Africa, the ECG in combination with office and home BP is an essential instrument in risk stratification across the entire BP range. © The Author 2017. Published by Oxford University Press on behalf of the American Journal of Hypertension, Ltd.

  5. On the normal scalar ECG. A new classification system considering age, sex and heart position.

    PubMed

    Lundh, B

    1984-01-01

    472 randomly selected men and women from the city of Lund were examined for disease in the heart, lungs and for hypertension. 163 men and 194 women who had no symptom or sign of disease were accepted for the further study. The prevalence of various exclusion criterias, such as symptoms and signs of heart disease, lung disease and other diseases which may possibly affect the ECG are reported as well as the distribution of blood pressures in the sample. A computer-averaged standard 12-lead ECG (leads aVL, I, -aVR, II, aVF, III, V1-V6) was recorded. All measurements of ECG-deflections have been made visually using a magnifying glass (6 times). ST-segments were classified according to the Punsar code by independent visual observers as well as by the computer. The mean frontal QRS-axis shifted to the left with advancing age, but the shift was statistically significant only in men. In both men and women there was a leftward shift of the mean frontal QRS-axis with increased weight, increased chest circumference and increased obesity index. The normal range of axis was found to be 0 degrees to 90 degrees in men and +15 degrees to 90 degrees in women. The problems concerning the definition of the electrical heart position is discussed. The concept of a Q-axis is introduced as an alternative way to indicate electrical heart position. There is a statistical significant relationship between the Q-axis and the QRS-axis in the frontal plane, although this relationship is not always apparent in the individual ECG. The presence or absence of a Q-wave in an individual lead was used to denote a lead as being a left ventricular lead or not. Using the Q-wave as a marker of heart position in the individual lead is more practical than to use the QRS-axis or the transitional zone. Duration and amplitude of the Q-wave have been measured. The upper limit of normal duration exceeded 0.03 s in leads aVL and aVF in men but not in women. The R-wave amplitudes proved to vary with age and heart

  6. Spatiotemporal Characteristics of QRS Complexes Enable the Diagnosis of Brugada Syndrome Regardless of the Appearance of a Type 1 ECG.

    PubMed

    Guillem, Maria S; Climent, Andreu M; Millet, José; Berne, Paola; Ramos, Rafael; Brugada, Josep; Brugada, Ramon

    2016-05-01

    The diagnosis of Brugada syndrome based on the ECG is hampered by the dynamic nature of its ECG manifestations. Brugada syndrome patients are only 25% likely to present a type 1 ECG. The objective of this study is to provide an ECG diagnostic criterion for Brugada syndrome patients that can be applied consistently even in the absence of a type 1 ECG. We recorded 67-lead body surface potential maps from 94 Brugada syndrome patients and 82 controls (including right bundle branch block patients and healthy individuals). The spatial propagation direction during the last r' wave and the slope at the end of the QRS complex were measured and compared between patients groups. Receiver-operating characteristic curves were constructed for half of the database to identify optimal cutoff values; sensitivity and specificity for these cutoff values were measured in the other half of the database. A spontaneous type 1 ECG was present in only 30% of BrS patients. An orientation in the sagittal plane < 101º during the last r' wave and a descending slope < 9.65 mV/s enables the diagnosis of the syndrome with a sensitivity of 69% and a specificity of 97% in non-type 1 Brugada syndrome patients. Spatiotemporal characteristics of surface ECG recordings can enable a robust identification of BrS even without the presence of a type 1 ECG. © 2016 Wiley Periodicals, Inc.

  7. Duration of general practitioner contracts.

    PubMed

    Abelsen, Birgit; Gaski, Margrete; Brandstorp, Helen

    2015-12-01

    The regular GP scheme is intended to promote continuity in the relationship between doctor and patient. The duration of GP contracts is therefore a key factor in the success of the scheme. This study examines how long the GP contracts last and whether their duration varies according to doctors' gender and age, municipality size and list size. The study encompasses 7,359 GP contracts throughout Norway, entered into between municipalities and doctors in the period 1 May 2001 - 1 May 2014. Duration is measured as the time from which the contract was signed until its expiry or the end of the study period. The material was analysed with measures of central tendencies and dispersion, Kaplan-Meier survival curve analysis and Cox proportional hazards regression. Median duration of a GP contract at the time of the study was 5.91 years. It varied between 2.75 years in the smallest municipalities and 8.37 years in the largest ones. The duration of a GP contract increased significantly if the doctor was a woman, or with the doctor's age at the start of the contract, increased municipality size and increased list size. If it is assumed that continuity in the doctor-patient relationship provides a qualitatively better GP service, the results indicate that patients in small municipalities are generally offered a lower-quality service than patients in large municipalities.

  8. Phonological Encoding and Phonetic Duration

    ERIC Educational Resources Information Center

    Fricke, Melinda Denise

    2013-01-01

    Studies of connected speech have repeatedly shown that the contextual predictability of a word is related to its phonetic duration; more predictable words tend to be produced with shorter duration, when other factors are controlled for (Aylett & Turk, 2004, 2006; Bell et al., 2003; Bell, Brenier, Gregory, Girand, & Jurafsky, 2009; Gahl,…

  9. A combined M5P tree and hazard-based duration model for predicting urban freeway traffic accident durations.

    PubMed

    Lin, Lei; Wang, Qian; Sadek, Adel W

    2016-06-01

    The duration of freeway traffic accidents duration is an important factor, which affects traffic congestion, environmental pollution, and secondary accidents. Among previous studies, the M5P algorithm has been shown to be an effective tool for predicting incident duration. M5P builds a tree-based model, like the traditional classification and regression tree (CART) method, but with multiple linear regression models as its leaves. The problem with M5P for accident duration prediction, however, is that whereas linear regression assumes that the conditional distribution of accident durations is normally distributed, the distribution for a "time-to-an-event" is almost certainly nonsymmetrical. A hazard-based duration model (HBDM) is a better choice for this kind of a "time-to-event" modeling scenario, and given this, HBDMs have been previously applied to analyze and predict traffic accidents duration. Previous research, however, has not yet applied HBDMs for accident duration prediction, in association with clustering or classification of the dataset to minimize data heterogeneity. The current paper proposes a novel approach for accident duration prediction, which improves on the original M5P tree algorithm through the construction of a M5P-HBDM model, in which the leaves of the M5P tree model are HBDMs instead of linear regression models. Such a model offers the advantage of minimizing data heterogeneity through dataset classification, and avoids the need for the incorrect assumption of normality for traffic accident durations. The proposed model was then tested on two freeway accident datasets. For each dataset, the first 500 records were used to train the following three models: (1) an M5P tree; (2) a HBDM; and (3) the proposed M5P-HBDM, and the remainder of data were used for testing. The results show that the proposed M5P-HBDM managed to identify more significant and meaningful variables than either M5P or HBDMs. Moreover, the M5P-HBDM had the lowest overall mean

  10. Scaling of chew cycle duration in primates.

    PubMed

    Ross, Callum F; Reed, David A; Washington, Rhyan L; Eckhardt, Alison; Anapol, Fred; Shahnoor, Nazima

    2009-01-01

    The biomechanical determinants of the scaling of chew cycle duration are important components of models of primate feeding systems at all levels, from the neuromechanical to the ecological. Chew cycle durations were estimated in 35 species of primates and analyzed in conjunction with data on morphological variables of the feeding system estimating moment of inertia of the mandible and force production capacity of the chewing muscles. Data on scaling of primate chew cycle duration were compared with the predictions of simple pendulum and forced mass-spring system models of the feeding system. The gravity-driven pendulum model best predicts the observed cycle duration scaling but is rejected as biomechanically unrealistic. The forced mass-spring model predicts larger increases in chew cycle duration with size than observed, but provides reasonable predictions of cycle duration scaling. We hypothesize that intrinsic properties of the muscles predict spring-like behavior of the jaw elevator muscles during opening and fast close phases of the jaw cycle and that modulation of stiffness by the central nervous system leads to spring-like properties during the slow close/power stroke phase. Strepsirrhines show no predictable relationship between chew cycle duration and jaw length. Anthropoids have longer chew cycle durations than nonprimate mammals with similar mandible lengths, possibly due to their enlarged symphyses, which increase the moment of inertia of the mandible. Deviations from general scaling trends suggest that both scaling of the jaw muscles and the inertial properties of the mandible are important in determining the scaling of chew cycle duration in primates.

  11. 28 CFR 17.24 - Duration of classification.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Duration of classification. 17.24 Section... ACCESS TO CLASSIFIED INFORMATION Classified Information § 17.24 Duration of classification. (a) At the... based on the duration of the national security sensitivity of the information. If the original...

  12. 5 CFR 301.203 - Duration of appointment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Duration of appointment. 301.203 Section... EMPLOYMENT Overseas Limited Appointment § 301.203 Duration of appointment. (a) An appointment under this subpart is of indefinite duration unless otherwise limited. (b) An agency may make an overseas limited...

  13. Nanoscale electrical property studies of individual GeSi quantum rings by conductive scanning probe microscopy.

    PubMed

    Lv, Yi; Cui, Jian; Jiang, Zuimin M; Yang, Xinju

    2012-11-29

    The nanoscale electrical properties of individual self-assembled GeSi quantum rings (QRs) were studied by scanning probe microscopy-based techniques. The surface potential distributions of individual GeSi QRs are obtained by scanning Kelvin microscopy (SKM). Ring-shaped work function distributions are observed, presenting that the QRs' rim has a larger work function than the QRs' central hole. By combining the SKM results with those obtained by conductive atomic force microscopy and scanning capacitance microscopy, the correlations between the surface potential, conductance, and carrier density distributions are revealed, and a possible interpretation for the QRs' conductance distributions is suggested.

  14. Electrocardiogram reference intervals for clinically normal wild-born chimpanzees (Pan troglodytes).

    PubMed

    Atencia, Rebeca; Revuelta, Luis; Somauroo, John D; Shave, Robert E

    2015-08-01

    To generate reference intervals for ECG variables in clinically normal chimpanzees (Pan troglodytes). 100 clinically normal (51 young [< 10 years old] and 49 adult [≥ 10 years old]) wild-born chimpanzees. Electrocardiograms collected between 2009 and 2013 at the Tchimpounga Chimpanzee Rehabilitation Centre were assessed to determine heart rate, PR interval, QRS duration, QT interval, QRS axis, P axis, and T axis. Electrocardiographic characteristics for left ventricular hypertrophy (LVH) and morphology of the ST segment, T wave, and QRS complex were identified. Reference intervals for young and old animals were calculated as mean ± 1.96•SD for normally distributed data and as 5th to 95th percentiles for data not normally distributed. Differences between age groups were assessed by use of unpaired Student t tests. RESULTS Reference intervals were generated for young and adult wild-born chimpanzees. Most animals had sinus rhythm with small or normal P wave morphology; 24 of 51 (47%) young chimpanzees and 30 of 49 (61%) adult chimpanzees had evidence of LVH as determined on the basis of criteria for humans. Cardiac disease has been implicated as the major cause of death in captive chimpanzees. Species-specific ECG reference intervals for chimpanzees may aid in the diagnosis and treatment of animals with, or at risk of developing, heart disease. Chimpanzees with ECG characteristics outside of these intervals should be considered for follow-up assessment and regular cardiac monitoring.

  15. Role of echocardiography before cardiac resynchronization therapy: new advances and current developments.

    PubMed

    Marechaux, Sylvestre; Menet, Aymeric; Guyomar, Yves; Ennezat, Pierre-Vladimir; Guerbaai, Raphaëlle Ashley; Graux, Pierre; Tribouilloy, Christophe

    2016-11-01

    The role of echocardiography in improving the selection of patients who will benefit from cardiac resynchronization therapy (CRT) remains a source of debate. Although previous landmark reports have demonstrated a link between mechanical dyssynchrony, assessed by delays between left ventricle (LV) walls and response to CRT, the predictive value of these findings has not yet been confirmed in multicenter trials. Indeed, recent studies demonstrated that the classical assessment of LV mechanical dyssynchrony using delay between walls by echocardiography depends not only on LV electrical activation delay (electrical dyssynchrony), but also on abnormalities in regional contractility of the LV and/or loading conditions, which do not represent an appropriate target for CRT. Recent reports highlighted the value of new indices of electromechanical dyssynchrony obtained by echocardiography, to predict LV response and outcome after CRT including septal flash, left bundle branch block-typical pattern by longitudinal strain, apical rocking, septal strain patterns, and systolic stretch index. This was achieved using a mechanistic approach, based on the contractile consequences of electrical dyssynchrony. These indices are rarely found in patients with narrow QRS (<120 ms), whereas their frequency rises in patients with an increase in QRS duration (>120 ms). Theses indices should improve candidate selection for CRT in clinical practice, especially for patients in whom the benefit of CRT remains uncertain, for example, patients with intermediate QRS width (120-150 ms). © 2016, Wiley Periodicals, Inc.

  16. Vestibular vertigo is associated with abnormal sleep duration.

    PubMed

    Albathi, Monirah; Agrawal, Yuri

    2017-01-01

    Several small studies in animals and humans have suggested a relationship between vestibular function and sleep. In this study, we evaluate the association between vestibular vertigo and sleep duration in a large, representative sample of US adults. We used data from the National Health Interview Survey, which administered a Balance Supplement in 2008 in a sample of 20,950 adult respondents. We evaluated the cross-sectional association between vestibular vertigo (based on a well-validated definition) and sleep duration (defined as short <6 hours, normal 6-8 hours, and long >8 hours). We performed multiple and multinomial logistic regression analyses to estimate the odds ratio and relative risk ratio (RRR) of impaired sleep duration compared to normal sleep duration associated with vestibular vertigo. Analyses were adjusted for demographic, lifestyle and health behavior characteristics as well as relevant comorbid conditions. Thirty percent of individuals with vestibular vertigo reported abnormal sleep duration (15.5% short duration and 14.8% long duration). In adjusted analyses, individuals with vestibular vertigo had a 1.75 (95% CI 1.45-2.11) RRR of having short sleep duration compared to individuals without vestibular vertigo, and a 1.55 (95% CI 1.26-1.91) RRR of having long sleep duration compared to individuals without vestibular vertigo. This study presents epidemiologic evidence to support the association between vestibular function and sleep duration. Individuals with vestibular vertigo had a higher RRR for abnormally short or long sleep duration. Further work is needed to evaluate the causal direction(s) of this association.

  17. Short term outcomes of long duration versus short duration tourniquet in primary total knee arthroplasty: A randomized controlled trial.

    PubMed

    Vaishya, Raju; Agarwal, Amit Kumar; Vijay, Vipul; Tiwari, Manish Kumar

    2018-01-01

    A tourniquet is used during the total knee replacement surgery to improve the visibility, to reduce the blood loss and for better cementation. Indirectly it decreases the duration of surgery and enhances the recovery of the patient. Their use however is controversial due to some side effects associated with the use of tourniquet. They may increase the risk of deep vein thrombosis and pulmonary embolism by causing venous stasis, endothelial damage and increased platelet adhesion secondary to distal limb ischemia. We conducted a randomized controlled trial (RCT) to examine the benefits and risks associated with the use of long duration over short duration tourniquets during TKA. The study was a prospective randomised control trial with a total of 80 knees (40 knees in each group) included in the study. The knees selected for surgery were randomly allocated to one of the two groups: Group A - long duration tourniquet (LT-group) or Group B - short duration tourniquet (ST-group). The average operating time in Group A (43.53±3.11 minutes) was statistically less significant than that of Group B (51.7±2.56 minutes). Intra-operative blood loss in Group B, was significantly more than that of Group A. Post-operative blood loss in the drain was more in long duration tourniquet group. Total blood loss (intra-operative + post-operative) was more in short duration tourniquet group. Pain score (using VAS scale) was comparable in both the groups at the end of the second and sixth week. At sixth weeks there was no significant difference in the range of motion in both the groups. The KSS score was not significantly different in both the groups in post operative period at first, second, and six weeks. There were no events of thrombo-embolism and deep vein thrombosis in either groups. In 11 patients (27.5%) of long duration tourniquet group, swelling, and redness of knee was seen post operatively as compared to three patients (7.5%) of short duration tourniquet group. The use of a

  18. Short duration flares in GALEX data

    NASA Astrophysics Data System (ADS)

    Brasseur, Clara; Osten, Rachel A.

    2018-06-01

    Flares on cool stars indicate short time-scale magnetic reconnection processes that provide temporary increases in the stellar radiative output. While recent work has focused on long-duration flares from solar-like stars and those of lower mass, the existence of short-duration flares in the ultraviolet has not been systematically probed before. We will present an interesting population of short duration flares we discovered in a sample of ~37,000 light curves observed from 2009-2012 by the GALEX and Kepler missions. These flares range in duration from under a minute to a few minutes and are almost entirely distinct from a previous flare survey of Kepler data. We were able to detect this unique population of flares because the time resolution of the GALEX data allowed us to construct light curves with a 10 second cadence and thus detect shorter duration flares than could be detected within Kepler data. We applied algorithmic flare detection to a sample of ~37,000 stars, and identified a final count of 2,065 flares on 1,121 stars. We discuss the implication of these events for the flare frequency distributions of solar-like stars.

  19. High-frequency ECG

    NASA Technical Reports Server (NTRS)

    Tragardh, Elin; Schlegel, Todd T.

    2006-01-01

    The standard ECG is by convention limited to 0.05-150 Hz, but higher frequencies are also present in the ECG signal. With high-resolution technology, it is possible to record and analyze these higher frequencies. The highest amplitudes of the high-frequency components are found within the QRS complex. In past years, the term "high frequency", "high fidelity", and "wideband electrocardiography" have been used by several investigators to refer to the process of recording ECGs with an extended bandwidth of up to 1000 Hz. Several investigators have tried to analyze HF-QRS with the hope that additional features seen in the QRS complex would provide information enhancing the diagnostic value of the ECG. The development of computerized ECG-recording devices that made it possible to record ECG signals with high resolution in both time and amplitude, as well as better possibilities to store and process the signals digitally, offered new methods for analysis. Different techniques to extract the HF-QRS have been described. Several bandwidths and filter types have been applied for the extraction as well as different signal-averaging techniques for noise reduction. There is no standard method for acquiring and quantifying HF-QRS. The physiological mechanisms underlying HF-QRS are still not fully understood. One theory is that HF-QRS are related to the conduction velocity and the fragmentation of the depolarization wave in the myocardium. In a three-dimensional model of the ventricles with a fractal conduction system it was shown that high numbers of splitting branches are associated with HF-QRS. In this experiment, it was also shown that the changes seen in HF-QRS in patients with myocardial ischemia might be due to the slowing of the conduction velocity in the region of ischemia. This mechanism has been tested by Watanabe et al by infusing sodium channel blockers into the left anterior descending artery in dogs. In their study, 60 unipolar ECGs were recorded from the entire

  20. Depth-Duration Frequency of Precipitation for Oklahoma

    USGS Publications Warehouse

    Tortorelli, Robert L.; Rea, Alan; Asquith, William H.

    1999-01-01

    A regional frequency analysis was conducted to estimate the depth-duration frequency of precipitation for 12 durations in Oklahoma (15, 30, and 60 minutes; 1, 2, 3, 6, 12, and 24 hours; and 1, 3, and 7 days). Seven selected frequencies, expressed as recurrence intervals, were investigated (2, 5, 10, 25, 50, 100, and 500 years). L-moment statistics were used to summarize depth-duration data and to determine the appropriate statistical distributions. Three different rain-gage networks provided the data (15minute, 1-hour, and 1-day). The 60-minute, and 1-hour; and the 24-hour, and 1-day durations were analyzed separately. Data were used from rain-gage stations with at least 10-years of record and within Oklahoma or about 50 kilometers into bordering states. Precipitation annual maxima (depths) were determined from the data for 110 15-minute, 141 hourly, and 413 daily stations. The L-moment statistics for depths for all durations were calculated for each station using unbiased L-mo-ment estimators for the mean, L-scale, L-coefficient of variation, L-skew, and L-kur-tosis. The relation between L-skew and L-kurtosis (L-moment ratio diagram) and goodness-of-fit measures were used to select the frequency distributions. The three-parameter generalized logistic distribution was selected to model the frequencies of 15-, 30-, and 60-minute annual maxima; and the three-parameter generalized extreme-value distribution was selected to model the frequencies of 1-hour to 7-day annual maxima. The mean for each station and duration was corrected for the bias associated with fixed interval recording of precipitation amounts. The L-scale and spatially averaged L-skew statistics were used to compute the location, scale, and shape parameters of the selected distribution for each station and duration. The three parameters were used to calculate the depth-duration-frequency relations for each station. The precipitation depths for selected frequencies were contoured from weighted depth

  1. Prevalence of sleep duration among Saudi adults

    PubMed Central

    Ahmed, Anwar E.; Al-Jahdali, Fares; AlALwan, Abdulaziz; Abuabat, Faisal; Salih, Salih Bin; Al-Harbi, Abdullah; Baharoon, Salim; Khan, Mohammad; Ali, Yosra Z.; Al-Jahdali, Hamdan

    2017-01-01

    Objectives: To examine the associations between sleep duration and a variety of demographic and clinical variables in a sample of Saudi adults. Methods: A cross-sectional study among 2,095 participants was conducted at King Abdulaziz Medical City, Riyadh, Kingdom of Saudi Arabia, between May and October 2014. A questionnaire was administered to collect data related to clinical health outcomes and demographic characteristics. Participants were asked to report their average sleep duration per night in hours. Results: One-third (33.8%) reported short sleep duration of less than 7 hours/night. Short sleep duration was more prevalent in females (37.3% versus 31.4%, p=0.004). The most common medical problems reported were obesity with body mass index of >30 Kg/m2 (39.1%), hypertension (33.9%), diabetes mellitus (20.8%), depression (4.3%), asthma (17.3%), COPD (6.6%), and hyperlipidemia (2.7%). Diabetes mellitus was associated with long sleep of more than 9 hours/night (25.4%, p=0.011) and hypertension (54.2%, p=0.001). The linear regression model tend to reduce their sleep duration by roughly 22 minutes in female gender, 66 minutes in participants with hyperlipidemia, and 70 minutes in participants with poor sleep quality. Conclusions: Short sleep duration per night was prevalent, it affects one in every 3 Saudi adults. Long sleep duration of more than 9 hours was associated with increased comorbid conditions. PMID:28251223

  2. Factors associated with short sleep duration in adolescents

    PubMed Central

    Felden, Érico Pereira Gomes; Filipin, Douglas; Barbosa, Diego Grasel; Andrade, Rubian Diego; Meyer, Carolina; Louzada, Fernando Mazilli

    2016-01-01

    Abstract Objective: This study aimed to investigate the prevalence and factors associated with short sleep duration in adolescents from Maravilha – Santa Catarina (SC), southern Brazil. Methods: The sample consisted of 516 adolescents aged 10–19 years of both genders. Issues associated with short sleep duration and difficulty falling asleep, chronotype, daytime sleepiness, physical activity, sedentary behavior and weight status were investigated. Results: The prevalence of short sleep duration (<8h on school days) was 53.6%. Adolescents aged 17–19 years showed a 2.05-fold (95%CI: 1.20–3.50) greater prevalence of short sleep duration than those aged 10–12 years. The ones studying in morning and evening shifts had a higher prevalence of short sleep duration compared to those in the afternoon shift. Older age and school shift were the main factors associated with short sleep duration. Conclusions: Adolescents from Maravilha showed high prevalence of short sleep duration, and older adolescents that studied in the morning and evening shifts showed reduced sleep. PMID:26559604

  3. Duration as a measure of the spiral aftereffect.

    DOT National Transportation Integrated Search

    1963-01-01

    Describes an experiment that studied the reliability of duration as a measure of the spiral aftereffect. The results for 10 Ss indicate that duration is a highly reliable measure and that duration is a simple monotonic function of exposure-time.

  4. Effects of pulse duration on magnetostimulation thresholds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saritas, Emine U., E-mail: saritas@ee.bilkent.edu.tr; Department of Electrical and Electronics Engineering, Bilkent University, Bilkent, Ankara 06800; National Magnetic Resonance Research Center

    Purpose: Medical imaging techniques such as magnetic resonance imaging and magnetic particle imaging (MPI) utilize time-varying magnetic fields that are subject to magnetostimulation limits, which often limit the speed of the imaging process. Various human-subject experiments have studied the amplitude and frequency dependence of these thresholds for gradient or homogeneous magnetic fields. Another contributing factor was shown to be number of cycles in a magnetic pulse, where the thresholds decreased with longer pulses. The latter result was demonstrated on two subjects only, at a single frequency of 1.27 kHz. Hence, whether the observed effect was due to the number ofmore » cycles or due to the pulse duration was not specified. In addition, a gradient-type field was utilized; hence, whether the same phenomenon applies to homogeneous magnetic fields remained unknown. Here, the authors investigate the pulse duration dependence of magnetostimulation limits for a 20-fold range of frequencies using homogeneous magnetic fields, such as the ones used for the drive field in MPI. Methods: Magnetostimulation thresholds were measured in the arms of six healthy subjects (age: 27 ± 5 yr). Each experiment comprised testing the thresholds at eight different pulse durations between 2 and 125 ms at a single frequency, which took approximately 30–40 min/subject. A total of 34 experiments were performed at three different frequencies: 1.2, 5.7, and 25.5 kHz. A solenoid coil providing homogeneous magnetic field was used to induce stimulation, and the field amplitude was measured in real time. A pre-emphasis based pulse shaping method was employed to accurately control the pulse durations. Subjects reported stimulation via a mouse click whenever they felt a twitching/tingling sensation. A sigmoid function was fitted to the subject responses to find the threshold at a specific frequency and duration, and the whole procedure was repeated at all relevant frequencies and pulse

  5. Type III Radio Burst Duration and SEP Events

    NASA Technical Reports Server (NTRS)

    Gopalswamy, N.; Makela, P.; Xie, H.

    2010-01-01

    Long-duration (>15 min), low-frequency (<14 MHz) type III radio bursts have been reported to be indicative of solar energetic particle events. We measured the durations of type III bursts associated with large SEP events of solar cycle 23. The Type III durations are distributed symmetrically at 1 MHz yielding a mean value of approximately 33 min (median = 32 min) for the large SEP events. When the SEP events with ground level enhancement (GLE,) are considered, the distribution is essentially unchanged (mean = 32 min, median = 30 min). To test the importance of type III bursts in indicating SEP events, we considered a set of six type III bursts from the same active region (AR 10588) whose durations fit the "long duration" criterion. We analyzed the coronal mass ejections (CMEs), flares, and type II radio bursts associated with the type III bursts. The CMEs were of similar speeds and the flares are also of similar size and duration. All but one of the type III bursts was not associated with a type II burst in the metric or longer wavelength domains. The burst without type II burst also lacked a solar energetic particle (SEP) event at energies >25 MeV. The 1-MHz duration of the type III burst (28 rein) is near the median value of type III durations found for gradual SEP events and ground level enhancement (GLE) events. Yet, there was no sign of SEP events. On the other hand, two other type III bursts from the same active region had similar duration but accompanied by WAVES type 11 bursts; these bursts were also accompanied by SEP events detected by SOHO/ERNE. This study suggests that the type III burst duration may not be a good indicator of an SEP event, consistent with the statistical study of Cliver and Ling (2009, ApJ ).

  6. Wall Thickness, Pulmonary Hypertension, and Diastolic Filling Abnormalities Predict Response to Postoperative Biventricular Pacing

    PubMed Central

    Brusen, Robin M.; Hahn, Rebecca; Cabreriza, Santos E.; Cheng, Bin; Wang, Daniel Y.; Truong, Wanda; Spotnitz, Henry M.

    2017-01-01

    Objective Post-cardiopulmonary bypass biventricular pacing improves hemodynamics but without clearly defined predictors of response. Based on preclinical studies and prior observations, it was suspected that diastolic dysfunction or pulmonary hypertension is predictive of hemodynamic benefit. Design Randomized controlled study of temporary biventricular pacing after cardiopulmonary bypass. Setting Single-center study at university-affiliated tertiary care hospital. Interventions Patients who underwent bypass with pre-operative ejection fraction ≤40% and QRS duration ≥100 ms or double-valve surgery were enrolled. At 3 time points between separation from bypass and postoperative day 1, pacing delays were varied to optimize hemodynamics. Participants Data from 43 patients were analyzed. Measurements and Main Results Cardiac output and arterial pressure were measured under no pacing, atrial pacing, and biventricular pacing. Preoperative echocardiograms and pulmonary artery catheterizations were reviewed, and measures of both systolic and diastolic function were compared to hemodynamic response. Early after separation, improvement in cardiac output was positively correlated with pulmonary vascular resistance (R2 = 0.97, p < 0.001), ventricle wall thickness (R2 = 0.72, p = 0.002)), and E/e′, a measure of abnormal diastolic ventricular filling velocity (R2 = 0.56, p = 0.04). Similar trends were seen with mean arterial pressure. QRS duration and ejection fraction did not correlate significantly with improvements in hemodynamics. Conclusions There may be an effect of biventricular pacing related to amelioration of abnormal diastolic filling patterns rather than electrical resynchronization in the postoperative state. PMID:25998068

  7. 12 CFR 1252.2 - Effective duration.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Effective duration. 1252.2 Section 1252.2 Banks and Banking FEDERAL HOUSING FINANCE AGENCY ENTERPRISES PORTFOLIO HOLDINGS § 1252.2 Effective duration. This part shall be in effect for each Enterprise so long as— (a) This part has not been superseded...

  8. Intravaginal vibrator of long duration.

    PubMed

    Ahmad, M

    2002-03-01

    Intravaginal foreign bodies of long duration are a rare entity and are seen in the practice of Obstetrics and Gynaecology, but patients may present to the Accident and Emergency department for their removal. Various bizarre objects have been inserted into the vagina and many patients are too embarrassed and will wait and try to remove them themselves rather than seek medical advice. Vaginal foreign bodies of long duration may be complicated by fistulas and such patients should be referred to the gynaecologist.

  9. Earth-space links and fade-duration statistics

    NASA Technical Reports Server (NTRS)

    Davarian, Faramaz

    1995-01-01

    In recent years, fade-duration statistics have been the subject of several experimental investigations. A good knowledge of the fade-duration distribution is important for the assessment of a satellite communication system's channel dynamics: What is a typical link outage duration? How often do link outages exceeding a given duration occur? Unfortunately there is yet no model that can universally answer the above questions. The available field measurements mainly come from temperate climatic zones and only from a few sites. Furthermore, the available statistics are also limited in the choice of frequency and path elevation angle. Yet, much can be learned from the available information. For example, we now know that the fade-duration distribution is approximately lognormal. Under certain conditions, we can even determine the median and other percentiles of the distribution. This paper reviews the available data obtained by several experimenters in different parts of the world. Areas of emphasis are mobile and fixed satellite links. Fades in mobile links are due to roadside-tree shadowing, whereas fades in fixed links are due to rain attenuation.

  10. Earth-Space Links and Fade-Duration Statistics

    NASA Technical Reports Server (NTRS)

    Davarian, Faramaz

    1996-01-01

    In recent years, fade-duration statistics have been the subject of several experimental investigations. A good knowledge of the fade-duration distribution is important for the assessment of a satellite communication system's channel dynamics: What is a typical link outage duration? How often do link outages exceeding a given duration occur? Unfortunately there is yet no model that can universally answer the above questions. The available field measurements mainly come from temperate climatic zones and only from a few sites. Furthermore, the available statistics are also limited in the choice of frequency and path elevation angle. Yet, much can be learned from the available information. For example, we now know that the fade-duration distribution is approximately lognormal. Under certain conditions, we can even determine the median and other percentiles of the distribution. This paper reviews the available data obtained by several experimenters in different parts of the world. Areas of emphasis are mobile and fixed satellite links. Fades in mobile links are due to roadside-tree shadowing, whereas fades in fixed links are due to rain attenuation.

  11. 16 CFR 613.1 - Duration of active duty alerts.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Duration of active duty alerts. 613.1 Section 613.1 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT DURATION OF ACTIVE DUTY ALERTS § 613.1 Duration of active duty alerts. The duration of an active duty alert shall be...

  12. 16 CFR 613.1 - Duration of active duty alerts.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Duration of active duty alerts. 613.1 Section 613.1 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT DURATION OF ACTIVE DUTY ALERTS § 613.1 Duration of active duty alerts. The duration of an active duty alert shall be...

  13. 16 CFR 613.1 - Duration of active duty alerts.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 1 2012-01-01 2012-01-01 false Duration of active duty alerts. 613.1 Section 613.1 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT DURATION OF ACTIVE DUTY ALERTS § 613.1 Duration of active duty alerts. The duration of an active duty alert shall be...

  14. Sleep Duration and Area-Level Deprivation in Twins

    PubMed Central

    Watson, Nathaniel F.; Horn, Erin; Duncan, Glen E.; Buchwald, Dedra; Vitiello, Michael V.; Turkheimer, Eric

    2016-01-01

    Study Objectives: We used quantitative genetic models to assess whether area-level deprivation as indicated by the Singh Index predicts shorter sleep duration and modifies its underlying genetic and environmental contributions. Methods: Participants were 4,218 adult twin pairs (2,377 monozygotic and 1,841 dizygotic) from the University of Washington Twin Registry. Participants self-reported habitual sleep duration. The Singh Index was determined by linking geocoding addresses to 17 indicators at the census-tract level using data from Census of Washington State and Census Tract Cartographic Boundary Files from 2000 and 2010. Data were analyzed using univariate and bivariate genetic decomposition and quantitative genetic interaction models that assessed A (additive genetics), C (common environment), and E (unique environment) main effects of the Singh Index on sleep duration and allowed the magnitude of residual ACE variance components in sleep duration to vary with the Index. Results: The sample had a mean age of 38.2 y (standard deviation [SD] = 18), and was predominantly female (62%) and Caucasian (91%). Mean sleep duration was 7.38 h (SD = 1.20) and the mean Singh Index score was 0.00 (SD = 0.89). The heritability of sleep duration was 39% and the Singh Index was 12%. The uncontrolled phenotypic regression of sleep duration on the Singh Index showed a significant negative relationship between area-level deprivation and sleep length (b = −0.080, P < 0.001). Every 1 SD in Singh Index was associated with a ∼4.5 min change in sleep duration. For the quasi-causal bivariate model, there was a significant main effect of E (b0E = −0.063; standard error [SE] = 0.30; P < 0.05). Residual variance components unique to sleep duration were significant for both A (b0Au = 0.734; SE = 0.020; P < 0.001) and E (b0Eu = 0.934; SE = 0.013; P < 0.001). Conclusions: Area-level deprivation has a quasi-causal association with sleep duration, with greater deprivation being related to

  15. Duration comparison: relative stimulus differences stimulus age, and stimulus predictiveness.

    PubMed Central

    Stubbs, D A; Dreyfus, L R; Fetterman, J G; Boynton, D M; Locklin, N; Smith, L D

    1994-01-01

    Under a psychophysical trials procedure, pigeons were presented with a red light of one duration followed by a green light of a second duration. Eight geometrically spaced base durations were paired with one of four shorter and four longer durations as the alternate member of a duration pair, with different pairs randomly intermixed. One choice was reinforced if red had lasted longer than green, and a second choice was reinforced if green had lasted longer. Performance was compared when all the base durations and their pair members were included (entire-range condition) or when only the four longest base durations and their comparison durations (restricted-range condition) were used. Discrimination sensitivity decreased for longer duration pairs under both conditions, supporting a memory-based account. Sensitivity was lower under the restricted-range condition. Under both conditions, a bias to report "green as longer" increased as the second green duration increased. Bias changed as a matching function of the green-duration predictiveness of the correct choice. The results are related to a quantitative model of timing and remembering proposed by Staddon. PMID:8064211

  16. Aviation System Analysis Capability Quick Response System Report

    NASA Technical Reports Server (NTRS)

    Roberts, Eileen; Villani, James A.; Ritter, Paul

    1998-01-01

    The purpose of this document is to present the additions and modifications made to the Aviation System Analysis Capability (ASAC) Quick Response System (QRS) in FY 1997 in support of the ASAC ORS development effort. This document contains an overview of the project background and scope and defines the QRS. The document also presents an overview of the Logistics Management Institute (LMI) facility that supports the QRS, and it includes a summary of the planned additions to the QRS in FY 1998. The document has five appendices.

  17. Sleep Duration and Area-Level Deprivation in Twins.

    PubMed

    Watson, Nathaniel F; Horn, Erin; Duncan, Glen E; Buchwald, Dedra; Vitiello, Michael V; Turkheimer, Eric

    2016-01-01

    We used quantitative genetic models to assess whether area-level deprivation as indicated by the Singh Index predicts shorter sleep duration and modifies its underlying genetic and environmental contributions. Participants were 4,218 adult twin pairs (2,377 monozygotic and 1,841 dizygotic) from the University of Washington Twin Registry. Participants self-reported habitual sleep duration. The Singh Index was determined by linking geocoding addresses to 17 indicators at the census-tract level using data from Census of Washington State and Census Tract Cartographic Boundary Files from 2000 and 2010. Data were analyzed using univariate and bivariate genetic decomposition and quantitative genetic interaction models that assessed A (additive genetics), C (common environment), and E (unique environment) main effects of the Singh Index on sleep duration and allowed the magnitude of residual ACE variance components in sleep duration to vary with the Index. The sample had a mean age of 38.2 y (standard deviation [SD] = 18), and was predominantly female (62%) and Caucasian (91%). Mean sleep duration was 7.38 h (SD = 1.20) and the mean Singh Index score was 0.00 (SD = 0.89). The heritability of sleep duration was 39% and the Singh Index was 12%. The uncontrolled phenotypic regression of sleep duration on the Singh Index showed a significant negative relationship between area-level deprivation and sleep length (b = -0.080, P < 0.001). Every 1 SD in Singh Index was associated with a ∼4.5 min change in sleep duration. For the quasi-causal bivariate model, there was a significant main effect of E (b(0E) = -0.063; standard error [SE] = 0.30; P < 0.05). Residual variance components unique to sleep duration were significant for both A (b(0Au) = 0.734; SE = 0.020; P < 0.001) and E (b(0Eu) = 0.934; SE = 0.013; P < 0.001). Area-level deprivation has a quasi-causal association with sleep duration, with greater deprivation being related to shorter sleep. As area-level deprivation

  18. Complex Biventricular Pacing - A Case Series

    PubMed Central

    Hodkinson, Emily Catherine; Morrice, Keith; Loan, William; Nicholas, Jacob; Chew, EngWooi

    2014-01-01

    It is established that cardiac resynchronisation therapy (CRT) reduces mortality and hospitalisation and improves functional class in patients with NYHA class 3-4 heart failure, an ejection fraction of ≤ 35% and a QRS duration of ≥ 120ms. Recent updates in the American guidelines have expanded the demographic of patients in whom CRT may be appropriate. Here we present two cases of complex CRT; one with a conventional indication but occluded central veins and the second with a novel indication for CRT post cardiac transplant. PMID:24493915

  19. Distinctive Left Ventricular Activations Associated With ECG Pattern in Heart Failure Patients.

    PubMed

    Derval, Nicolas; Duchateau, Josselin; Mahida, Saagar; Eschalier, Romain; Sacher, Frederic; Lumens, Joost; Cochet, Hubert; Denis, Arnaud; Pillois, Xavier; Yamashita, Seigo; Komatsu, Yuki; Ploux, Sylvain; Amraoui, Sana; Zemmoura, Adlane; Ritter, Philippe; Hocini, Mélèze; Haissaguerre, Michel; Jaïs, Pierre; Bordachar, Pierre

    2017-06-01

    In contrast to patients with left bundle branch block (LBBB), heart failure patients with narrow QRS and nonspecific intraventricular conduction delay (NICD) display a relatively limited response to cardiac resynchronization therapy. We sought to compare left ventricular (LV) activation patterns in heart failure patients with narrow QRS and NICD to patients with LBBB using high-density electroanatomic activation maps. Fifty-two heart failure patients (narrow QRS [n=18], LBBB [n=11], NICD [n=23]) underwent 3-dimensional electroanatomic mapping with a high density of mapping points (387±349 LV). Adjunctive scar imaging was available in 37 (71%) patients and was analyzed in relation to activation maps. LBBB patients typically demonstrated (1) a single LV breakthrough at the septum (38±15 ms post-QRS onset); (2) prolonged right-to-left transseptal activation with absence of direct LV Purkinje activity; (3) homogeneous propagation within the LV cavity; and (4) latest activation at the basal lateral LV. In comparison, both NICD and narrow QRS patients demonstrated (1) multiple LV breakthroughs along the posterior or anterior fascicles: narrow QRS versus LBBB, 5±2 versus 1±1; P =0.0004; NICD versus LBBB, 4±2 versus 1±1; P =0.001); (2) evidence of early/pre-QRS LV electrograms with Purkinje potentials; (3) rapid propagation in narrow QRS patients and more heterogeneous propagation in NICD patients; and (4) presence of limited areas of late activation associated with LV scar with high interindividual heterogeneity. In contrast to LBBB patients, narrow QRS and NICD patients are characterized by distinct mechanisms of LV activation, which may predict poor response to cardiac resynchronization therapy. © 2017 American Heart Association, Inc.

  20. Impaired T-wave amplitude adaptation to heart-rate induced by cardiac deconditioning after 5-days of head-down bed-rest

    NASA Astrophysics Data System (ADS)

    Caiani, Enrico G.; Pellegrini, Alessandro; Bolea, Juan; Sotaquira, Miguel; Almeida, Rute; Vaïda, Pierre

    2013-10-01

    The study of QT/RR relationship is important for the clinical evaluation of possible risk of acquired or congenital ventricular tachyarrhythmias. In the hypothesis that microgravity exposure could induce changes in the repolarization mechanisms, our aim was to test if a short 5-days strict 6° head-down bed-rest (HDBR) could induce alterations in the QT/RR relationship and spatial repolarization heterogeneity. Twenty-two healthy men (mean age 31±6) were enrolled as part of the European Space Agency HDBR studies. High fidelity (1000 Hz) 24 h Holter ECG (12-leads, Mortara Instrument) was acquired before (PRE), the last day of HDBR (HDT5), and four days after its conclusion (POST). The night period (23:00-06:30) was selected for analysis. X, Y, Z leads were derived and the vectorcardiogram computed. Selective beat averaging was used to obtain averages of P-QRS-T complexes preceded by the same RR (10 ms bin amplitude, in the range 900-1200 ms). For each averaged waveform (i.e., one for each bin), T-wave maximum amplitude (Tmax), T-wave area (Tarea), RTapex, RTend, ventricular gradient (VG) magnitude and spatial QRS-T angle were computed. Non-parametric Friedman test was applied. Compared to PRE, at HDT5 both RTapex and RTend resulted shortened (-4%), with a decrease in T-wave amplitude (-8%) and area (-13%). VG was diminished by 10%, and QRS-T angle increased by 14°. At POST, QT duration and area parameters, as well as QRS-T angle were restored while Tmax resulted larger than PRE (+5%) and VG was still decreased by 3%. Also, a marked loss in strength of the linear regression with RR was found at HDT5 in Tmax and Tarea, that could represent a new dynamic marker of increased risk for life-threatening arrhythmias. Despite the short-term HDBR, ventricular repolarization during the night period was affected. This should be taken into account in astronauts for risk assessment during space flight.

  1. Sleep Duration and Depressive Symptoms: A Gene-Environment Interaction

    PubMed Central

    Watson, Nathaniel F.; Harden, Kathryn Paige; Buchwald, Dedra; Vitiello, Michael V.; Pack, Allan I.; Strachan, Eric; Goldberg, Jack

    2014-01-01

    Objective: We used quantitative genetic models to assess whether sleep duration modifies genetic and environmental influences on depressive symptoms. Method: Participants were 1,788 adult twins from 894 same-sex twin pairs (192 male and 412 female monozygotic [MZ] pairs, and 81 male and 209 female dizygotic [DZ] pairs] from the University of Washington Twin Registry. Participants self-reported habitual sleep duration and depressive symptoms. Data were analyzed using quantitative genetic interaction models, which allowed the magnitude of additive genetic, shared environmental, and non-shared environmental influences on depressive symptoms to vary with sleep duration. Results: Within MZ twin pairs, the twin who reported longer sleep duration reported fewer depressive symptoms (ec = -0.17, SE = 0.06, P < 0.05). There was a significant gene × sleep duration interaction effect on depressive symptoms (a'c = 0.23, SE = 0.08, P < 0.05), with the interaction occurring on genetic influences that are common to both sleep duration and depressive symptoms. Among individuals with sleep duration within the normal range (7-8.9 h/night), the total heritability (h2) of depressive symptoms was approximately 27%. However, among individuals with sleep duration within the low (< 7 h/night) or high (≥ 9 h/night) range, increased genetic influence on depressive symptoms was observed, particularly at sleep duration extremes (5 h/night: h2 = 53%; 10 h/night: h2 = 49%). Conclusion: Genetic contributions to depressive symptoms increase at both short and long sleep durations. Citation: Watson NF; Harden KP; Buchwald D; Vitiello MV; Pack AI; Stachan E; Goldberg J. Sleep duration and depressive symptoms: a gene-environment interaction. SLEEP 2014;37(2):351-358. PMID:24497663

  2. An investigation of the spatial selectivity of the duration after-effect.

    PubMed

    Maarseveen, Jim; Hogendoorn, Hinze; Verstraten, Frans A J; Paffen, Chris L E

    2017-01-01

    Adaptation to the duration of a visual stimulus causes the perceived duration of a subsequently presented stimulus with a slightly different duration to be skewed away from the adapted duration. This pattern of repulsion following adaptation is similar to that observed for other visual properties, such as orientation, and is considered evidence for the involvement of duration-selective mechanisms in duration encoding. Here, we investigated whether the encoding of duration - by duration-selective mechanisms - occurs early on in the visual processing hierarchy. To this end, we investigated the spatial specificity of the duration after-effect in two experiments. We measured the duration after-effect at adapter-test distances ranging between 0 and 15° of visual angle and for within- and between-hemifield presentations. We replicated the duration after-effect: the test stimulus was perceived to have a longer duration following adaptation to a shorter duration, and a shorter duration following adaptation to a longer duration. Importantly, this duration after-effect occurred at all measured distances, with no evidence for a decrease in the magnitude of the after-effect at larger distances or across hemifields. This shows that adaptation to duration does not result from adaptation occurring early on in the visual processing hierarchy. Instead, it seems likely that duration information is a high-level stimulus property that is encoded later on in the visual processing hierarchy. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Associations of electrocardiographic P-wave characteristics with left atrial function, and diffuse left ventricular fibrosis defined by cardiac magnetic resonance: The PRIMERI Study.

    PubMed

    Tiffany Win, Theingi; Ambale Venkatesh, Bharath; Volpe, Gustavo J; Mewton, Nathan; Rizzi, Patricia; Sharma, Ravi K; Strauss, David G; Lima, Joao A; Tereshchenko, Larisa G

    2015-01-01

    Abnormal P-terminal force in lead V1 (PTFV1) is associated with an increased risk of heart failure, stroke, atrial fibrillation, and death. Our goal was to explore associations of left ventricular (LV) diffuse fibrosis with left atrial (LA) function and electrocardiographic (ECG) measures of LA electrical activity. Patients without atrial fibrillation (n = 91; mean age 59.5 years; 61.5% men; 65.9% white) with structural heart disease (spatial QRS-T angle ≥105° and/or Selvester QRS score ≥5 on ECG) but LV ejection fraction >35% underwent clinical evaluation, cardiac magnetic resonance, and resting ECG. LA function indices were obtained by multimodality tissue tracking using 2- and 4-chamber long-axis images. T1 mapping and late gadolinium enhancement were used to assess diffuse LV fibrosis and presence of scar. P-prime in V1 amplitude (PPaV1) and duration (PPdV1), averaged P-wave-duration, PR interval, and P-wave axis were automatically measured using 12 SLTM algorithm. PTFV1 was calculated as a product of PPaV1 and PPdV1. In linear regression after adjustment for demographic characteristics, body mass index, maximum LA volume index, presence of scar, and LV mass index, each decile increase in LV interstitial fibrosis was associated with 0.76 mV*ms increase in negative abnormal PTFV1 (95% confidence interval [CI] -1.42 to -0.09; P = .025), 15.3 ms prolongation of PPdV1 (95% CI 6.9 to 23.8; P = .001) and 5.4 ms prolongation of averaged P-duration (95% CI 0.9-10.0; P = .020). LV fibrosis did not affect LA function. PPaV1 and PTFV1 were associated with an increase in LA volumes and decrease in LA emptying fraction and LA reservoir function. LV interstitial fibrosis is associated with abnormal PTFV1, prolonged PPdV1, and P-duration, but does not affect LA function. Copyright © 2015 Heart Rhythm Society. All rights reserved.

  4. Spectral analysis of 87-lead body surface signal-averaged ECGs in patients with previous anterior myocardial infarction as a marker of ventricular tachycardia.

    PubMed

    Hosoya, Y; Kubota, I; Shibata, T; Yamaki, M; Ikeda, K; Tomoike, H

    1992-06-01

    There were few studies on the relation between the body surface distribution of high- and low-frequency components within the QRS complex and ventricular tachycardia (VT). Eighty-seven signal-averaged ECGs were obtained from 30 normal subjects (N group) and 30 patients with previous anterior myocardial infarction (MI) with VT (MI-VT[+] group, n = 10) or without VT (MI-VT[-] group, n = 20). The onset and offset of the QRS complex were determined from 87-lead root mean square values computed from the averaged (but not filtered) ECG waveforms. Fast Fourier transform analysis was performed on signal-averaged ECG. The resulting Fourier coefficients were attenuated by use of the transfer function, and then inverse transform was done with five frequency ranges (0-25, 25-40, 40-80, 80-150, and 150-250 Hz). From the QRS onset to the QRS offset, the time integration of the absolute value of reconstructed waveforms was calculated for each of the five frequency ranges. The body surface distributions of these areas were expressed as QRS area maps. The maximal values of QRS area maps were compared among the three groups. In the frequency ranges of 0-25 and 150-250 Hz, there were no significant differences in the maximal values among these three groups. Both MI groups had significantly smaller maximal values of QRS area maps in the frequency ranges of 25-40 and 40-80 Hz compared with the N group. The MI-VT(+) group had significantly smaller maximal values in the frequency ranges of 40-80 and 80-150 Hz than the MI-VT(-) group. These three groups were clearly differentiated by the maximal values of the 40-80-Hz QRS area map. It was suggested that the maximal value of the 40-80-Hz QRS area map was a new marker for VT after anterior MI.

  5. New micro waveforms firstly recorded on electrocardiogram in human.

    PubMed

    Liu, Renguang; Chang, Qinghua; Chen, Juan

    2015-10-01

    In our study, not only the P-QRS-T waves but also the micro-wavelets before QRS complex (in P wave and PR segment) and after QRS complex (ST segment and upstroke of T wave) were first to be identified on surface electrocardiogram in human by the "new electrocardiogram" machine (model PHS-A10) according to conventional 12-lead electrocardiogram connection methods. By comparison to the conventional electrocardiogram in 100 cases of healthy individuals and several patients with arrhythmias, we have found that the wavelets before P wave theoretically reflected electrical activity of sinus node and the micro-wavelets before QRS complex may be related to atrioventricular conduction system (atrioventricular node, His bundle and bundle branch) potentials. Noninvasive atrioventricular node and His bundle potential tracing will contribute to differentiation of the origin of wide QRS and the location of the atrioventricular block. We also have found that the wavelets after QRS complex may be associated with phase 2 and 3 repolarization of ventricular action potential, which will further reveal ventricular repolarization changes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Factors affecting gestation duration in the bitch.

    PubMed

    Eilts, Bruce E; Davidson, Autumn P; Hosgood, Giselle; Paccamonti, Dale L; Baker, David G

    2005-07-15

    A retrospective analysis was performed to determine the effects of age, breed, parity, and litter size on the duration of gestation in the bitch. Bitches at two locations were monitored from breeding to whelping. A total of 764 litters whelped from 308 bitches (36 large hounds, 34 Golden Retrievers, 23 German Shepherd Dogs (GSD), and 215 Labrador Retrievers). By breed, the number of whelpings was 152, 72, 58, and 482 for the hounds, Golden Retrievers, German Shepherd Dogs, and Labrador Retrievers, respectively. Whelping was predicted to be 57 d from the first day of cytologic diestrus in the hounds or 65 d from the initial progesterone rise in the other breeds. The average gestation duration (calculated as 8 d prior to Day 1 of cytologic diestrus in hounds or measured from the initial progesterone rise in other breeds) by breed (days +/- S.D.) was 66.0 +/- 2.8, 64.7 +/- 1.5, 63.6 +/- 2.1, and 62.9 +/- 1.3 for the hounds, Golden Retrievers, German Shepherd Dogs, and Labrador Retrievers, respectively. The relationship of age, breed, parity, and litter size with the difference in gestation duration was evaluated using log linear modeling. Age or parity had no effect on gestation duration. Compared to Labrador Retrievers, the German Shepherd Dogs, Golden Retrievers and hounds were more likely to have a longer gestation duration; three, four and nearly eight times as likely, respectively. Bitches whelping four or fewer pups were significantly more likely to have a longer gestation duration than those whelping five or more pups; the prolongation averaging 1 d.

  7. Factors that Influence Weekday Sleep Duration in European Children

    PubMed Central

    Hense, Sabrina; Barba, Gianvincenzo; Pohlabeln, Hermann; De Henauw, Stefaan; Marild, Staffan; Molnar, Dénes; Moreno, Luis A.; Hadjigeorgiou, Charalampos; Veidebaum, Toomas; Ahrens, Wolfgang

    2011-01-01

    Study Objectives: To compare nocturnal sleep duration in children from 8 European countries and identify its determinants. Design: Cross-sectional. Setting: Primary schools and preschools participating in the IDEFICS study. Participants: 8,542 children aged 2 to 9 years from 8 European countries with complete information on nocturnal sleep duration. Interventions: Not applicable. Measurements: Nocturnal sleep duration was assessed by means of a computer based parental 24-h recall. Data on personal, social, environmental, and behavioral factors were collected by means of standardized parental questionnaire. Physical activity was surveyed with accelerometers. Results: Nocturnal sleep duration in the participating countries ranged from 9.5 h (SD 0.8) in Estonia to 11.2 h (SD 0.7) in Belgium and differed significantly between countries (P < 0.001) in univariate as well as in multivariate analyses, with children from northern countries sleeping the longest. Sleep duration decreased by about 6 min with each year of age over all countries. No effect of season, daylight duration, overweight, parental education level, or lifestyle factors could be seen. Conclusion: Sleep duration differs significantly between countries. Our findings allow for the conclusion that regional affiliation, including culture and environmental characteristics, seems to overlay individual determinants of sleep duration. Citation: Hense S; Barba G; Pohlabeln H; De Henauw S; Marild S; Molnar D; Moreno LA; Hadjigeorgiou C; Veidebaum T; Ahrens W. Factors that influence weekday sleep duration in European children. SLEEP 2011;34(5):633-639. PMID:21532957

  8. Associations between insomnia, sleep duration and poor work ability.

    PubMed

    Lian, Yulong; Xiao, Jing; Liu, Yan; Ning, Li; Guan, Suzhen; Ge, Hua; Li, Fuye; Liu, Jiwen

    2015-01-01

    The aim of this study was to examine the independent and joint effect of insomnia and objective sleep duration on poor work ability. In this cross-sectional study, a total of 2820 Chinese manufacturing workers were categorized as insomnia patients and individuals with normal sleeping pattern by interview according to DSM-IV criteria. Sleep duration was classified into four categories: ≥7h, 6-7h, 5-6h, and <5h according to objective sleep duration of Watch-PAT-200 test. Work ability was assessed using the Chinese Work Ability Index (WAI) questionnaire. Regression analysis examined the independent and joint association of sleep duration and insomnia with poor work ability, after adjusting for various confounding factors. Insomnia and objective short sleep duration were both independently associated with poor work ability. Compared with the normal sleeping and ≥7h sleep duration group, the highest risk of poor work ability was in the insomnia patients with <5h sleep duration [odds ratio (OR) 3.43, 95% confidence interval (CI) 1.87-5.23], followed by the individuals with insomnia who slept 5-6h (OR 2.03, 95% CI 1.42-2.67). Insomnia and sleep duration in workers are both separately and together associated with increased risk of poor work ability. Objective sleep duration should be taken into consideration when assessing the work ability of people with insomnia. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Ideal engine durations for gamma-ray-burst-jet launch

    NASA Astrophysics Data System (ADS)

    Hamidani, Hamid; Takahashi, Koh; Umeda, Hideyuki; Okita, Shinpei

    2017-08-01

    Aiming to study gamma-ray-burst (GRB) engine duration, we present numerical simulations to investigate collapsar jets. We consider typical explosion energy (1052 erg) but different engine durations, in the widest domain to date from 0.1 to 100 s. We employ an adaptive mesh refinement 2D hydrodynamical code. Our results show that engine duration strongly influences jet nature. We show that the efficiency of launching and collimating relativistic outflow increases with engine duration, until the intermediate engine range where it is the highest, past this point to long engine range, the trend is slightly reversed; we call this point where acceleration and collimation are the highest 'sweet spot' (˜10-30 s). Moreover, jet energy flux shows that variability is also high in this duration domain. We argue that not all engine durations can produce the collimated, relativistic and variable long GRB jets. Considering a typical progenitor and engine energy, we conclude that the ideal engine duration to reproduce a long GRB is ˜10-30 s, where the launch of relativistic, collimated and variable jets is favoured. We note that this duration domain makes a good link with a previous study suggesting that the bulk of Burst and Transient Source Experiment's long GRBs is powered by ˜10-20 s collapsar engines.

  10. 49 CFR 543.8 - Duration of exemption.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 6 2010-10-01 2010-10-01 false Duration of exemption. 543.8 Section 543.8 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION EXEMPTION FROM VEHICLE THEFT PREVENTION STANDARD § 543.8 Duration of...

  11. 7 CFR 985.69 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 985.69 Section 985.69 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING....69 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by...

  12. 7 CFR 920.66 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 920.66 Section 920.66 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING... Miscellaneous Provisions § 920.66 Duration of immunities. The benefits, priviliges, and immunities conferred...

  13. 7 CFR 930.86 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 930.86 Section 930.86 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... Handling Miscellaneous Provisions § 930.86 Duration of immunities. The benefits, privileges, and immunities...

  14. 7 CFR 920.66 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 920.66 Section 920.66 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING... Miscellaneous Provisions § 920.66 Duration of immunities. The benefits, priviliges, and immunities conferred...

  15. 7 CFR 930.86 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 930.86 Section 930.86 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING... Handling Miscellaneous Provisions § 930.86 Duration of immunities. The benefits, privileges, and immunities...

  16. 7 CFR 947.83 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 947.83 Section 947.83 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING... Miscellaneous Provisions § 947.83 Duration of immunities. The benefits, privileges, and immunities conferred...

  17. 7 CFR 985.69 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 985.69 Section 985.69 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing....69 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by...

  18. 7 CFR 930.86 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 930.86 Section 930.86 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... Handling Miscellaneous Provisions § 930.86 Duration of immunities. The benefits, privileges, and immunities...

  19. 7 CFR 985.69 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 985.69 Section 985.69 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing....69 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by...

  20. 7 CFR 930.86 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 930.86 Section 930.86 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING... Handling Miscellaneous Provisions § 930.86 Duration of immunities. The benefits, privileges, and immunities...

  1. 7 CFR 920.66 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 920.66 Section 920.66 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... Miscellaneous Provisions § 920.66 Duration of immunities. The benefits, priviliges, and immunities conferred...

  2. 7 CFR 929.72 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 929.72 Section 929.72 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of...

  3. 7 CFR 985.69 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 985.69 Section 985.69 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing....69 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by...

  4. 7 CFR 929.72 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 929.72 Section 929.72 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of...

  5. 7 CFR 920.66 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 920.66 Section 920.66 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... Miscellaneous Provisions § 920.66 Duration of immunities. The benefits, priviliges, and immunities conferred...

  6. 7 CFR 947.83 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 947.83 Section 947.83 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... Miscellaneous Provisions § 947.83 Duration of immunities. The benefits, privileges, and immunities conferred...

  7. 7 CFR 985.69 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 985.69 Section 985.69 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING....69 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by...

  8. 7 CFR 929.72 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 929.72 Section 929.72 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of...

  9. 7 CFR 929.72 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 929.72 Section 929.72 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING... Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of...

  10. 7 CFR 947.83 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 947.83 Section 947.83 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... Miscellaneous Provisions § 947.83 Duration of immunities. The benefits, privileges, and immunities conferred...

  11. 7 CFR 930.86 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 930.86 Section 930.86 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... Handling Miscellaneous Provisions § 930.86 Duration of immunities. The benefits, privileges, and immunities...

  12. 7 CFR 947.83 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 947.83 Section 947.83 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... Miscellaneous Provisions § 947.83 Duration of immunities. The benefits, privileges, and immunities conferred...

  13. 7 CFR 947.83 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 947.83 Section 947.83 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING... Miscellaneous Provisions § 947.83 Duration of immunities. The benefits, privileges, and immunities conferred...

  14. 7 CFR 929.72 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 929.72 Section 929.72 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING... Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of...

  15. 7 CFR 920.66 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 920.66 Section 920.66 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... Miscellaneous Provisions § 920.66 Duration of immunities. The benefits, priviliges, and immunities conferred...

  16. 49 CFR 525.9 - Duration of exemption.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 6 2014-10-01 2014-10-01 false Duration of exemption. 525.9 Section 525.9 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION EXEMPTIONS FROM AVERAGE FUEL ECONOMY STANDARDS § 525.9 Duration of...

  17. 45 CFR 2400.53 - Duration of stipend.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 45 Public Welfare 4 2014-10-01 2014-10-01 false Duration of stipend. 2400.53 Section 2400.53 Public Welfare Regulations Relating to Public Welfare (Continued) JAMES MADISON MEMORIAL FELLOWSHIP FOUNDATION FELLOWSHIP PROGRAM REQUIREMENTS Fellowship Stipend § 2400.53 Duration of stipend. Stipends for...

  18. 45 CFR 2400.53 - Duration of stipend.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 45 Public Welfare 4 2012-10-01 2012-10-01 false Duration of stipend. 2400.53 Section 2400.53 Public Welfare Regulations Relating to Public Welfare (Continued) JAMES MADISON MEMORIAL FELLOWSHIP FOUNDATION FELLOWSHIP PROGRAM REQUIREMENTS Fellowship Stipend § 2400.53 Duration of stipend. Stipends for...

  19. 45 CFR 2400.53 - Duration of stipend.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 45 Public Welfare 4 2013-10-01 2013-10-01 false Duration of stipend. 2400.53 Section 2400.53 Public Welfare Regulations Relating to Public Welfare (Continued) JAMES MADISON MEMORIAL FELLOWSHIP FOUNDATION FELLOWSHIP PROGRAM REQUIREMENTS Fellowship Stipend § 2400.53 Duration of stipend. Stipends for...

  20. 45 CFR 2400.53 - Duration of stipend.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Duration of stipend. 2400.53 Section 2400.53 Public Welfare Regulations Relating to Public Welfare (Continued) JAMES MADISON MEMORIAL FELLOWSHIP FOUNDATION FELLOWSHIP PROGRAM REQUIREMENTS Fellowship Stipend § 2400.53 Duration of stipend. Stipends for...

  1. 45 CFR 2400.53 - Duration of stipend.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 45 Public Welfare 4 2011-10-01 2011-10-01 false Duration of stipend. 2400.53 Section 2400.53 Public Welfare Regulations Relating to Public Welfare (Continued) JAMES MADISON MEMORIAL FELLOWSHIP FOUNDATION FELLOWSHIP PROGRAM REQUIREMENTS Fellowship Stipend § 2400.53 Duration of stipend. Stipends for...

  2. 7 CFR 1450.205 - Duration of contracts.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 10 2011-01-01 2011-01-01 false Duration of contracts. 1450.205 Section 1450.205...) Establishment Payments and Annual Payments § 1450.205 Duration of contracts. (a) Contracts under this subpart... conditions (for example, establishment time frame, winter hardiness), and other factors. ...

  3. 7 CFR 3434.7 - Duration of certification.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 15 2013-01-01 2013-01-01 false Duration of certification. 3434.7 Section 3434.7 Agriculture Regulations of the Department of Agriculture (Continued) NATIONAL INSTITUTE OF FOOD AND AGRICULTURE HISPANIC-SERVING AGRICULTURAL COLLEGES AND UNIVERSITIES CERTIFICATION PROCESS § 3434.7 Duration of...

  4. 7 CFR 3434.7 - Duration of certification.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 15 2014-01-01 2014-01-01 false Duration of certification. 3434.7 Section 3434.7 Agriculture Regulations of the Department of Agriculture (Continued) NATIONAL INSTITUTE OF FOOD AND AGRICULTURE HISPANIC-SERVING AGRICULTURAL COLLEGES AND UNIVERSITIES CERTIFICATION PROCESS § 3434.7 Duration of...

  5. Power supplies for long duration balloon flights

    NASA Astrophysics Data System (ADS)

    Lichfield, Ernest W.

    Long duration balloon flights require more electrical power than can be carried in primary batteries. This paper provides design information for selecting rechargeable batteries and charging systems. Solar panels for recharging batteries are discussed, with particular emphasis on cells mounting suitable for balloon flights and panel orientation for maximum power collection. Since efficient utilization of power is so important, modern DC to DC power conversion techniques are presented. On short flights of 1 day or less, system designers have not been greatly concerned with battery weight. But, with the advent of long duration balloon flights using superpressure balloons, anchor balloon systems, and RACOON balloon techniques, power supplies and their weight become of prime importance. The criteria for evaluating power systems for long duration balloon flights is performance per unit weight. Instrumented balloon systems have flown 44 days. For these very long duration flights, batteries recharged from solar cells are the only solution. For intermediate flight duration, say less than 10 days, the system designer should seriously consider using primary cells. The National Center for Atmospheric Research is sponsored by the National Science Foundation. Any opinions, findings and conclusions or recommendations expressed in this publication are those of the authors and do not necessarily reflect the views of the National Science Foundation.

  6. Issues for the Next Decade of Quality Rating and Improvement Systems. Issue Brief. Publication #2009-14

    ERIC Educational Resources Information Center

    Tout, Kathryn; Zaslow, Martha; Halle, Tamara; Forry, Nicole

    2009-01-01

    Since the first child care Quality Rating System (QRS) was implemented in Oklahoma 11 years ago (in 1998), 16 additional statewide systems have been launched and numerous states are piloting or developing a QRS (Zaslow, Tout, & Martinez-Beck, forthcoming). As QRS stakeholders across the nation look ahead to the next decade, it is important to take…

  7. Human auditory event-related potentials predict duration judgments.

    PubMed

    Bendixen, Alexandra; Grimm, Sabine; Schröger, Erich

    2005-08-05

    Internal clock models postulate a pulse accumulation process underlying timing activities, with more accumulated pulses resulting in longer perceived durations. We investigated whether this accumulation is reflected in the amplitude of event-related brain potentials (ERPs) elicited by auditory stimuli with durations of 400-600 ms. In a duration discrimination paradigm, we found more negative amplitudes to physically identical stimuli when they were judged as longer than the memorized standard duration (500 ms) as compared to being classified as shorter. This sustained negativity was already developing during the first 100 ms after stimulus onset. It could not be explained as a bias to respond with a particular hand (lateralized readiness potential), but rather reflects a processing difference between the tones to be judged as shorter or longer. Our results are in line with models of time processing which assume that higher numbers of accumulated pulses of a temporal processor result in an increase in perceived duration.

  8. [Associations of the work duration, sleep duration and number of holidays with an exaggerated blood pressure response during an exercise stress test among workers].

    PubMed

    Michishita, Ryoma; Ohta, Masanori; Ikeda, Masaharu; Jiang, Ying; Yamato, Hiroshi

    2016-01-01

    It has been reported that an exaggerated systolic blood pressure (ESBP) response during exercise, even if resting blood pressure is normal, is associated with an increased risk of future hypertension and cardiovascular disease (CVD). This study was designed to investigate the relationships of work duration, sleep duration and number of holidays with blood pressure response during an exercise stress test among normotensive workers. The subjects were 362 normotensive workers (79 males and 283 females; age, 49.1 years). A multi-stage graded submaximal exercise stress test was performed on each subject using an electric bicycle ergometer. The workload was increased every 3 minutes, and blood pressure was measured at rest and during the last 1 minute of each stage. In this study, an ESBP response during exercise was defined according to the criteria of the Framingham Study (peak systolic blood pressure ≥210 mmHg in males, or ≥190 mmHg in females). Working environments, work duration, sleep duration, number of holidays, and physical activity during commuting and work, and leisure time exercise duration were evaluated using a questionnaire. An ESBP response during exercise was observed in 94 (26.0%) workers. The adjusted odds ratio for the prevalence of an ESBP response during exercise was found to be significantly higher with an increase in work duration, decreases in sleep duration and number of holidays (p<0.05, respectively). Moreover, the highest work duration with lowest sleep duration and number of holidays groups had significantly higher adjusted odds ratio for the prevalence of an ESBP response during exercise than the lowest work duration with highest sleep duration and number of holidays groups (p<0.05, respectively). Based on our results, we consider that the assessment of blood pressure response during exercise and daily life are necessary to prevent the incidence of future hypertension, CVD and death due to overwork in workers with long-work duration

  9. 7 CFR 927.72 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 927.72 Section 927.72... WASHINGTON Order Regulating Handling Miscellaneous Provisions § 927.72 Duration of immunities. The benefits, privileges, and immunities conferred by virtue of this subpart shall cease upon termination hereof, except...

  10. 7 CFR 945.86 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 945.86 Section 945.86 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING... § 945.86 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by...

  11. 7 CFR 927.72 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 927.72 Section 927.72... WASHINGTON Order Regulating Handling Miscellaneous Provisions § 927.72 Duration of immunities. The benefits, privileges, and immunities conferred by virtue of this subpart shall cease upon termination hereof, except...

  12. 7 CFR 945.86 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 945.86 Section 945.86 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING... § 945.86 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by...

  13. 7 CFR 922.67 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 922.67 Section 922.67... COUNTIES IN WASHINGTON Order Regulating Handling Miscellaneous Provisions § 922.67 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall...

  14. 7 CFR 989.88 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 989.88 Section 989.88... GROWN IN CALIFORNIA Order Regulating Handling Miscellaneous Provisions § 989.88 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this amended subpart...

  15. 7 CFR 989.88 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 989.88 Section 989.88... GROWN IN CALIFORNIA Order Regulating Handling Miscellaneous Provisions § 989.88 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this amended subpart...

  16. 7 CFR 927.72 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 927.72 Section 927.72... WASHINGTON Order Regulating Handling Miscellaneous Provisions § 927.72 Duration of immunities. The benefits, privileges, and immunities conferred by virtue of this subpart shall cease upon termination hereof, except...

  17. 7 CFR 958.83 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 958.83 Section 958.83 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING... § 958.83 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by...

  18. 7 CFR 958.83 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 958.83 Section 958.83 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING... § 958.83 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by...

  19. 7 CFR 948.87 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 948.87 Section 948.87... Order Regulating Handling Miscellaneous Provisions § 948.87 Duration of immunities. The benefits, privileges and immunities conferred upon any person by virtue of this subpart shall cease upon the...

  20. 7 CFR 948.87 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 948.87 Section 948.87... Order Regulating Handling Miscellaneous Provisions § 948.87 Duration of immunities. The benefits, privileges and immunities conferred upon any person by virtue of this subpart shall cease upon the...

  1. 7 CFR 948.87 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 948.87 Section 948.87... Order Regulating Handling Miscellaneous Provisions § 948.87 Duration of immunities. The benefits, privileges and immunities conferred upon any person by virtue of this subpart shall cease upon the...

  2. 7 CFR 989.88 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 989.88 Section 989.88... GROWN IN CALIFORNIA Order Regulating Handling Miscellaneous Provisions § 989.88 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this amended subpart...

  3. 7 CFR 922.67 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 922.67 Section 922.67... COUNTIES IN WASHINGTON Order Regulating Handling Miscellaneous Provisions § 922.67 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall...

  4. 7 CFR 922.67 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 922.67 Section 922.67... COUNTIES IN WASHINGTON Order Regulating Handling Miscellaneous Provisions § 922.67 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall...

  5. 7 CFR 945.86 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 945.86 Section 945.86 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... § 945.86 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by...

  6. 7 CFR 922.67 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 922.67 Section 922.67... COUNTIES IN WASHINGTON Order Regulating Handling Miscellaneous Provisions § 922.67 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall...

  7. 7 CFR 958.83 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 958.83 Section 958.83 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... § 958.83 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by...

  8. 7 CFR 989.88 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 989.88 Section 989.88... GROWN IN CALIFORNIA Order Regulating Handling Miscellaneous Provisions § 989.88 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this amended subpart...

  9. 7 CFR 945.86 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 945.86 Section 945.86 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... § 945.86 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by...

  10. 7 CFR 922.67 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 922.67 Section 922.67... COUNTIES IN WASHINGTON Order Regulating Handling Miscellaneous Provisions § 922.67 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall...

  11. 7 CFR 945.86 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 945.86 Section 945.86 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... § 945.86 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by...

  12. 7 CFR 924.67 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 924.67 Section 924.67 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... § 924.67 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by...

  13. 7 CFR 927.72 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 927.72 Section 927.72... WASHINGTON Order Regulating Handling Miscellaneous Provisions § 927.72 Duration of immunities. The benefits, privileges, and immunities conferred by virtue of this subpart shall cease upon termination hereof, except...

  14. 7 CFR 989.88 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 989.88 Section 989.88... GROWN IN CALIFORNIA Order Regulating Handling Miscellaneous Provisions § 989.88 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this amended subpart...

  15. 7 CFR 958.83 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 958.83 Section 958.83 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... § 958.83 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by...

  16. 7 CFR 958.83 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 958.83 Section 958.83 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... § 958.83 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by...

  17. 7 CFR 927.72 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 927.72 Section 927.72... WASHINGTON Order Regulating Handling Miscellaneous Provisions § 927.72 Duration of immunities. The benefits, privileges, and immunities conferred by virtue of this subpart shall cease upon termination hereof, except...

  18. 7 CFR 948.87 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 948.87 Section 948.87... Order Regulating Handling Miscellaneous Provisions § 948.87 Duration of immunities. The benefits, privileges and immunities conferred upon any person by virtue of this subpart shall cease upon the...

  19. 7 CFR 924.67 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 924.67 Section 924.67 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... § 924.67 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by...

  20. 7 CFR 948.87 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 948.87 Section 948.87... Order Regulating Handling Miscellaneous Provisions § 948.87 Duration of immunities. The benefits, privileges and immunities conferred upon any person by virtue of this subpart shall cease upon the...

  1. 6 CFR 7.24 - Duration of classification.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 6 Domestic Security 1 2010-01-01 2010-01-01 false Duration of classification. 7.24 Section 7.24 Domestic Security DEPARTMENT OF HOMELAND SECURITY, OFFICE OF THE SECRETARY CLASSIFIED NATIONAL SECURITY INFORMATION Classified Information § 7.24 Duration of classification. (a) At the time of original...

  2. Duration on unemployment: geographic mobility and selectivity bias.

    PubMed

    Goss, E P; Paul, C; Wilhite, A

    1994-01-01

    Modeling the factors affecting the duration of unemployment was found to be influenced by the inclusion of migration factors. Traditional models which did not control for migration factors were found to underestimate movers' probability of finding an acceptable job. The empirical test of the theory, based on the analysis of data on US household heads unemployed in 1982 and employed in 1982 and 1983, found that the cumulative probability of reemployment in the traditional model was .422 and in the migration selectivity model was .624 after 30 weeks of searching. In addition, controlling for selectivity eliminated the significance of the relationship between race and job search duration in the model. The relationship between search duration and the county unemployment rate in 1982 became statistically significant, and the relationship between search duration and 1980 population per square mile in the 1982 county of residence became statistically insignificant. The finding that non-Whites have a longer duration of unemployment can better be understood as non-Whites' lower geographic mobility and lack of greater job contacts. The statistical significance of a high unemployment rate in the home labor market reducing the probability of finding employment was more in keeping with expectations. The findings assumed that the duration of employment accurately reflected the length of job search. The sample was redrawn to exclude discouraged workers and the analysis was repeated. The findings were similar to the full sample, with the coefficient for migration variable being negative and statistically significant and the coefficient for alpha remaining positive and statistically significant. Race in the selectivity model remained statistically insignificant. The findings supported the Schwartz model hypothesizing that the expansion of the radius of the search would reduce the duration of unemployment. The exclusion of the migration factor misspecified the equation for

  3. Estimated flow-duration curves for selected ungaged sites in Kansas

    USGS Publications Warehouse

    Studley, S.E.

    2001-01-01

    Flow-duration curves for 1968-98 were estimated for 32 ungaged sites in the Missouri, Smoky Hill-Saline, Solomon, Marais des Cygnes, Walnut, Verdigris, and Neosho River Basins in Kansas. Also included from a previous report are estimated flow-duration curves for 16 ungaged sites in the Cimarron and lower Arkansas River Basins in Kansas. The method of estimation used six unique factors of flow duration: (1) mean streamflow and percentage duration of mean streamflow, (2) ratio of 1-percent-duration streamflow to mean streamflow, (3) ratio of 0.1-percent-duration streamflow to 1-percent-duration streamflow, (4) ratio of 50-percent-duration streamflow to mean streamflow, (5) percentage duration of appreciable streamflow (0.10 cubic foot per second), and (6) average slope of the flow-duration curve. These factors were previously developed from a regionalized study of flow-duration curves using streamflow data for 1921-76 from streamflow-gaging stations with drainage areas of 100 to 3,000 square miles. The method was tested on a currently (2001) measured, continuous-record streamflow-gaging station on Salt Creek near Lyndon, Kansas, with a drainage area of 111 square miles and was found to adequately estimate the computed flow-duration curve for the station. The method also was tested on a currently (2001) measured, continuous-record, streamflow-gaging station on Soldier Creek near Circleville, Kansas, with a drainage area of 49.3 square miles. The results of the test on Soldier Creek near Circleville indicated that the method could adequately estimate flow-duration curves for sites with drainage areas of less than 100 square miles. The low-flow parts of the estimated flow-duration curves were verified or revised using 137 base-flow discharge measurements made during 1999-2000 at the 32 ungaged sites that were correlated with base-flow measurements and flow-duration analyses performed at nearby, long-term, continuous-record, streamflow-gaging stations (index stations

  4. The Latest Developments in NASA's Long Duration Balloon Systems

    NASA Astrophysics Data System (ADS)

    Stilwell, Bryan D.

    The Latest Developments in NASA’s Long Duration Balloon Systems Bryan D. Stilwell, bryan.stilwell@csbf.nasa.gov Columbia Scientific Balloon Facility, Palestine, Texas, USA The Columbia Scientific Balloon Facility, located in Palestine, Texas offers the scientific community a high altitude balloon based communications platform. Scientific payload mass can exceed 2722 kg with balloon float altitudes on average of 40000 km and flight duration of up to 100 days. Many developments in electrical systems have occurred over the more than 25 years of long duration flights. This paper will discuss the latest developments in electronic systems related to long duration flights. Over the years, the long duration flights have increased in durations exceeding 56 days. In order to support these longer flights, the systems have had to increase in complexity and reliability. Several different systems that have been upgraded and/or enhanced will be discussed.

  5. Duration of Menopausal Hot Flushes and Associated Risk Factors

    PubMed Central

    Freeman, Ellen W.; Sammel, Mary D.; Lin, Hui; Liu, Ziyue; Gracia, Clarisa R.

    2011-01-01

    OBJECTIVE To estimate the duration of moderate-to-severe menopausal hot flushes and identify potential risk factors for hot flush duration. METHODS The Penn Ovarian Aging Study cohort was followed for 13 years. Hot flushes were evaluated at 9-month to 12-month intervals through in-person interviews. The primary outcome was the duration of moderate to severe hot flushes, estimated by survival analysis (N=259). Potential risk factors included menopausal stage, age, race, reproductive hormone levels, body mass index (BMI) and current smoking. A secondary analysis included women who reported any hot flushes (N=349). RESULTS The median duration of moderate to severe hot flushes was 10.2 years and was strongly associated with menopausal stage at onset. Hot flushes that commenced near entry into the menopause transition had a median duration >greater than 11.57 years; onset in the early transition stage had a median duration of 7.35 years (95% CI 4.94, 8.89), P<0.001); and onset in the late transition to postmenopausal stages had a median duration of 3.84 years (95% CI: 1.77, 5.52), P<0.001. The most common ages at onset of moderate-to-severe hot flushes were 45–49 years (median duration 8.1 years; 95% CI 5.12, 9.28). African American women had a longer duration of hot flushes than white women in adjusted analysis. CONCLUSIONS The median duration of hot flushes considerably exceeded the time frame that is generally accepted in clinical practice. The identified risk factors, particularly menopausal stage, race, and BMI, are important to consider in individualizing treatment and evaluating the risk to benefit ratio of hormones and other therapies. PMID:21508748

  6. Correlation between Sleep Duration and Risk of Stroke.

    PubMed

    Patyar, Sazal; Patyar, Rakesh Raman

    2015-05-01

    Modern lifestyle and job requirements have changed the sleep habits of most of the adult population. Various population-based studies have associated an increase in mortality with either shortened sleep or long sleep duration. Thus a U-shaped relationship between sleep duration and all-cause mortality in both men and women has been suggested. Several studies have found an association between sleep duration and risk of cardiovascular diseases also. Efforts to understand the etiology of stroke have indicated an association between sleep and stroke too. Obstructive sleep apnea, a sleep-related disorder, has been reported to significantly increase the risk of stroke. Moreover, many studies have shown that both short and long sleep durations are related to increased likelihood of diabetes and hypertension, which themselves are risk factors for stroke. Therefore, this review focuses on the correlation between sleep duration and risk of stroke based on the experimental and epidemiologic studies. Although a few experimental studies have reported that partial sleep deprivation may reduce stroke incidence and severity, yet, most experimental and observational studies have indicated a strong association between short/long sleep durations and higher risk of stroke. Copyright © 2015 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  7. 7 CFR 953.78 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 953.78 Section 953.78... SOUTHEASTERN STATES Order Regulating Handling Miscellaneous Provisions § 953.78 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon...

  8. 7 CFR 915.67 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 915.67 Section 915.67... Order Regulating Handling Miscellaneous Provisions § 915.67 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this part shall cease upon its termination...

  9. 7 CFR 981.88 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 981.88 Section 981.88... Regulating Handling Miscellaneous Provisions § 981.88 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon its termination except with...

  10. 7 CFR 981.88 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 981.88 Section 981.88... Regulating Handling Miscellaneous Provisions § 981.88 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon its termination except with...

  11. 7 CFR 953.78 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 953.78 Section 953.78... SOUTHEASTERN STATES Order Regulating Handling Miscellaneous Provisions § 953.78 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon...

  12. 7 CFR 946.73 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 946.73 Section 946.73... WASHINGTON Order Regulating Handling Miscellaneous Provisions § 946.73 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the...

  13. 7 CFR 993.87 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 993.87 Section 993.87... CALIFORNIA Order Regulating Handling Miscellaneous Provisions § 993.87 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the...

  14. 7 CFR 932.71 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 932.71 Section 932.71... Regulating Handling Miscellaneous Provisions § 932.71 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the termination of this...

  15. 7 CFR 946.73 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 946.73 Section 946.73... WASHINGTON Order Regulating Handling Miscellaneous Provisions § 946.73 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the...

  16. 7 CFR 984.87 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 984.87 Section 984.87... Regulating Handling Miscellaneous Provisions § 984.87 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the termination hereof except...

  17. 7 CFR 983.85 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 983.85 Section 983.85..., ARIZONA, AND NEW MEXICO Miscellaneous Provisions § 983.85 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this part shall cease upon its termination...

  18. 7 CFR 925.66 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 925.66 Section 925.66... OF SOUTHEASTERN CALIFORNIA Miscellaneous Provisions § 925.66 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this part shall cease upon its termination...

  19. 7 CFR 966.87 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 966.87 Section 966.87... Regulating Handling Miscellaneous Provisions § 966.87 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the termination of this...

  20. 7 CFR 932.71 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 932.71 Section 932.71... Regulating Handling Miscellaneous Provisions § 932.71 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the termination of this...

  1. 7 CFR 959.87 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 959.87 Section 959.87... Regulating Handling Miscellaneous Provisions § 959.87 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the termination of this...

  2. 7 CFR 966.87 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 966.87 Section 966.87... Regulating Handling Miscellaneous Provisions § 966.87 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the termination of this...

  3. 7 CFR 925.66 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 925.66 Section 925.66... OF SOUTHEASTERN CALIFORNIA Miscellaneous Provisions § 925.66 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this part shall cease upon its termination...

  4. 7 CFR 984.87 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 984.87 Section 984.87... Regulating Handling Miscellaneous Provisions § 984.87 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the termination hereof except...

  5. 7 CFR 953.78 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 953.78 Section 953.78... SOUTHEASTERN STATES Order Regulating Handling Miscellaneous Provisions § 953.78 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon...

  6. 7 CFR 993.87 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 993.87 Section 993.87... CALIFORNIA Order Regulating Handling Miscellaneous Provisions § 993.87 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the...

  7. 7 CFR 916.67 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 916.67 Section 916.67... Order Regulating Handling Miscellaneous Provisions § 916.67 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this part shall cease upon its termination...

  8. 7 CFR 993.87 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 993.87 Section 993.87... CALIFORNIA Order Regulating Handling Miscellaneous Provisions § 993.87 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the...

  9. 7 CFR 915.67 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 915.67 Section 915.67... Order Regulating Handling Miscellaneous Provisions § 915.67 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this part shall cease upon its termination...

  10. 7 CFR 917.65 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 917.65 Section 917.65... CALIFORNIA Order Regulating Handling Miscellaneous Provisions § 917.65 Duration of immunities. The benefits, privileges, and immunities conferred by virtue of the provisions of this subpart shall cease upon its...

  11. 7 CFR 982.84 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 982.84 Section 982.84... WASHINGTON Order Regulating Handling Miscellaneous Provisions § 982.84 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the...

  12. 7 CFR 915.67 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 915.67 Section 915.67... Order Regulating Handling Miscellaneous Provisions § 915.67 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this part shall cease upon its termination...

  13. 7 CFR 982.84 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 982.84 Section 982.84... WASHINGTON Order Regulating Handling Miscellaneous Provisions § 982.84 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the...

  14. 7 CFR 993.87 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 993.87 Section 993.87... CALIFORNIA Order Regulating Handling Miscellaneous Provisions § 993.87 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the...

  15. 7 CFR 959.87 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 959.87 Section 959.87... Regulating Handling Miscellaneous Provisions § 959.87 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the termination of this...

  16. 7 CFR 932.71 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 932.71 Section 932.71... Regulating Handling Miscellaneous Provisions § 932.71 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the termination of this...

  17. 7 CFR 915.67 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 915.67 Section 915.67... Order Regulating Handling Miscellaneous Provisions § 915.67 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this part shall cease upon its termination...

  18. 7 CFR 946.73 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 946.73 Section 946.73... WASHINGTON Order Regulating Handling Miscellaneous Provisions § 946.73 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the...

  19. 7 CFR 932.71 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 932.71 Section 932.71... Regulating Handling Miscellaneous Provisions § 932.71 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the termination of this...

  20. 7 CFR 917.65 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 917.65 Section 917.65... CALIFORNIA Order Regulating Handling Miscellaneous Provisions § 917.65 Duration of immunities. The benefits, privileges, and immunities conferred by virtue of the provisions of this subpart shall cease upon its...

  1. 7 CFR 959.87 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 959.87 Section 959.87... Regulating Handling Miscellaneous Provisions § 959.87 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the termination of this...

  2. 7 CFR 983.85 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 983.85 Section 983.85..., ARIZONA, AND NEW MEXICO Miscellaneous Provisions § 983.85 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this part shall cease upon its termination...

  3. 7 CFR 982.84 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 982.84 Section 982.84... WASHINGTON Order Regulating Handling Miscellaneous Provisions § 982.84 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the...

  4. 7 CFR 915.67 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 915.67 Section 915.67... Order Regulating Handling Miscellaneous Provisions § 915.67 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this part shall cease upon its termination...

  5. 7 CFR 966.87 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 966.87 Section 966.87... Regulating Handling Miscellaneous Provisions § 966.87 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the termination of this...

  6. 7 CFR 959.87 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 959.87 Section 959.87... Regulating Handling Miscellaneous Provisions § 959.87 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the termination of this...

  7. 7 CFR 984.87 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 984.87 Section 984.87... Regulating Handling Miscellaneous Provisions § 984.87 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the termination hereof except...

  8. 7 CFR 981.88 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 981.88 Section 981.88... Regulating Handling Miscellaneous Provisions § 981.88 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon its termination except with...

  9. 7 CFR 917.65 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 917.65 Section 917.65... CALIFORNIA Order Regulating Handling Miscellaneous Provisions § 917.65 Duration of immunities. The benefits, privileges, and immunities conferred by virtue of the provisions of this subpart shall cease upon its...

  10. 7 CFR 984.87 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 984.87 Section 984.87... Regulating Handling Miscellaneous Provisions § 984.87 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the termination hereof except...

  11. 7 CFR 983.85 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 983.85 Section 983.85..., ARIZONA, AND NEW MEXICO Miscellaneous Provisions § 983.85 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this part shall cease upon its termination...

  12. 7 CFR 917.65 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 917.65 Section 917.65... CALIFORNIA Order Regulating Handling Miscellaneous Provisions § 917.65 Duration of immunities. The benefits, privileges, and immunities conferred by virtue of the provisions of this subpart shall cease upon its...

  13. 7 CFR 982.84 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 982.84 Section 982.84... WASHINGTON Order Regulating Handling Miscellaneous Provisions § 982.84 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the...

  14. 7 CFR 984.87 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 984.87 Section 984.87... Regulating Handling Miscellaneous Provisions § 984.87 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the termination hereof except...

  15. 7 CFR 925.66 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 925.66 Section 925.66... OF SOUTHEASTERN CALIFORNIA Miscellaneous Provisions § 925.66 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this part shall cease upon its termination...

  16. 7 CFR 993.87 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 993.87 Section 993.87... CALIFORNIA Order Regulating Handling Miscellaneous Provisions § 993.87 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the...

  17. 7 CFR 946.73 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 946.73 Section 946.73... WASHINGTON Order Regulating Handling Miscellaneous Provisions § 946.73 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the...

  18. 7 CFR 953.78 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 953.78 Section 953.78... SOUTHEASTERN STATES Order Regulating Handling Miscellaneous Provisions § 953.78 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon...

  19. 7 CFR 917.65 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 917.65 Section 917.65... CALIFORNIA Order Regulating Handling Miscellaneous Provisions § 917.65 Duration of immunities. The benefits, privileges, and immunities conferred by virtue of the provisions of this subpart shall cease upon its...

  20. 7 CFR 981.88 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 981.88 Section 981.88... Regulating Handling Miscellaneous Provisions § 981.88 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon its termination except with...

  1. 7 CFR 981.88 - Duration of immunities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Duration of immunities. 981.88 Section 981.88... Regulating Handling Miscellaneous Provisions § 981.88 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon its termination except with...

  2. 7 CFR 959.87 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 959.87 Section 959.87... Regulating Handling Miscellaneous Provisions § 959.87 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the termination of this...

  3. 7 CFR 966.87 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 966.87 Section 966.87... Regulating Handling Miscellaneous Provisions § 966.87 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the termination of this...

  4. 7 CFR 932.71 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 932.71 Section 932.71... Regulating Handling Miscellaneous Provisions § 932.71 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the termination of this...

  5. 7 CFR 982.84 - Duration of immunities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Duration of immunities. 982.84 Section 982.84... WASHINGTON Order Regulating Handling Miscellaneous Provisions § 982.84 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the...

  6. 7 CFR 925.66 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 925.66 Section 925.66... OF SOUTHEASTERN CALIFORNIA Miscellaneous Provisions § 925.66 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this part shall cease upon its termination...

  7. 7 CFR 946.73 - Duration of immunities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Duration of immunities. 946.73 Section 946.73... WASHINGTON Order Regulating Handling Miscellaneous Provisions § 946.73 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the...

  8. 7 CFR 925.66 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 925.66 Section 925.66... OF SOUTHEASTERN CALIFORNIA Miscellaneous Provisions § 925.66 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this part shall cease upon its termination...

  9. 7 CFR 953.78 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 953.78 Section 953.78... SOUTHEASTERN STATES Order Regulating Handling Miscellaneous Provisions § 953.78 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon...

  10. 7 CFR 983.85 - Duration of immunities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Duration of immunities. 983.85 Section 983.85..., ARIZONA, AND NEW MEXICO Miscellaneous Provisions § 983.85 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this part shall cease upon its termination...

  11. 7 CFR 916.67 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 916.67 Section 916.67... Order Regulating Handling Miscellaneous Provisions § 916.67 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this part shall cease upon its termination...

  12. 7 CFR 966.87 - Duration of immunities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Duration of immunities. 966.87 Section 966.87... Regulating Handling Miscellaneous Provisions § 966.87 Duration of immunities. The benefits, privileges, and immunities conferred upon any person by virtue of this subpart shall cease upon the termination of this...

  13. 10 CFR 52.61 - Duration of renewal.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Duration of renewal. 52.61 Section 52.61 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSES, CERTIFICATIONS, AND APPROVALS FOR NUCLEAR POWER PLANTS Standard Design Certifications § 52.61 Duration of renewal. Each renewal of certification for a standard design...

  14. 42 CFR 61.13 - Duration and continuation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Duration and continuation. 61.13 Section 61.13 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES FELLOWSHIPS, INTERNSHIPS, TRAINING FELLOWSHIPS Regular Fellowships § 61.13 Duration and continuation. An award period may be any...

  15. 42 CFR 61.13 - Duration and continuation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Duration and continuation. 61.13 Section 61.13 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES FELLOWSHIPS, INTERNSHIPS, TRAINING FELLOWSHIPS Regular Fellowships § 61.13 Duration and continuation. An award period may be any...

  16. 42 CFR 61.13 - Duration and continuation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Duration and continuation. 61.13 Section 61.13 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES FELLOWSHIPS, INTERNSHIPS, TRAINING FELLOWSHIPS Regular Fellowships § 61.13 Duration and continuation. An award period may be any...

  17. 42 CFR 61.13 - Duration and continuation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Duration and continuation. 61.13 Section 61.13 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES FELLOWSHIPS, INTERNSHIPS, TRAINING FELLOWSHIPS Regular Fellowships § 61.13 Duration and continuation. An award period may be any...

  18. 42 CFR 61.13 - Duration and continuation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Duration and continuation. 61.13 Section 61.13 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES FELLOWSHIPS, INTERNSHIPS, TRAINING FELLOWSHIPS Regular Fellowships § 61.13 Duration and continuation. An award period may be any...

  19. Inverse relationship between sleep duration and myopia.

    PubMed

    Jee, Donghyun; Morgan, Ian G; Kim, Eun Chul

    2016-05-01

    To investigate the association between sleep duration and myopia. This population-based, cross-sectional study using a nationwide, systemic, stratified, multistage, clustered sampling method included a total of 3625 subjects aged 12-19 years who participated in the Korean National Health and Nutrition Examination Survey 2008-2012. All participants underwent ophthalmic examination and a standardized interview including average sleep duration (hr/day), education, physical activity and economic status (annual household income). Refractive error was measured by autorefraction without cycloplegia. Myopia and high myopia were defined as ≤-0.50 dioptres (D) and ≤-6.0 D, respectively. Sleep durations were classified into 5 categories: <5, 6, 7, 8 and >9 hr. The overall prevalence of myopia and high myopia were 77.8% and 9.4%, respectively, and the overall sleep duration was 7.1 hr/day. The refractive error increased by 0.10 D per 1 hr increase in sleep after adjusting for potential confounders including sex, age, height, education level, economic status and physical activity. The adjusted odds ratio (OR) for refractive error was 0.90 (95% confidence interval [CI], 0.83-0.97) per 1 hr increase in sleep. The adjusted OR for myopia was decreased in those with >9 hr of sleep (OR, 0.59; 95% CI, 0.38-0.93; p for trend = 0.006) than in those with <5 hr of sleep. However, high myopia was not associated with sleep duration. This study provides the population-based, epidemiologic evidence for an inverse relationship between sleep duration and myopia in a representative population of Korean adolescents. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  20. Electronic and optical properties of HEMT heterostructures with δ-Si doped GaAs/AlGaAs quantum rings — quantum well system

    NASA Astrophysics Data System (ADS)

    Sibirmovsky, Y. D.; Vasil'evskii, I. S.; Vinichenko, A. N.; Zhigunov, D. M.; Eremin, I. S.; Kolentsova, O. S.; Safonov, D. A.; Kargin, N. I.

    2017-11-01

    Samples of δ-Si doped AlGaAs/GaAs/AlGaAs HEMT heterostructures with GaAs quantum rings (QRs) on top of the quantum well (QW) were grown by molecular beam epitaxy and their properties were compared to the reference samples without QRs. The thickness of the QW was 6 - 10 nm for the samples with QRs and 20 nm for the reference samples. Photoluminescence measurements at low temperatures for all samples show at least two distinct lines in addition to the bulk GaAs line. The Hall effect and low temperature magnetotransport measurements at 4 - 320 K show that conductivity with and without illumination decreases significantly with QRs introduction, however the relative photoconductivity increases. Samples with 6 nm QW are insulating, which could be caused by the strong localization of the charge carriers in the QRs.

  1. [Brain Mechanisms for Measuring Time: Population Coding of Durations].

    PubMed

    Hayashi, Masamichi J

    2016-11-01

    Temporal processing is crucial in many aspects of our perception and action. While there is mounting evidence for the encoding mechanisms of spatial ("where") and identity ("what") information, those of temporal information ("when") remain largely unknown. Recent studies suggested that, similarly to the basic visual stimulus features such as orientation, motion direction, and numerical quantity, event durations are also represented by a population of neurons that are tuned for specific, preferred durations. This paper first reviews recent psychophysical studies on duration aftereffect. Changes in the three parameters (response gain, shift, and width of tuning curves) are then discussed that may need to be taken into account in the putative duration-channel model. Next, the potential neural basis of the duration channels is examined by overviewing recent neuroimaging and electrophysiological studies on time perception. Finally, this paper proposes a general neural basis of timing that commonly represents time-differences independent of stimulus types (e.g., a single duration v.s. multiple brief events). This extends the idea of the "when pathway" from the perception of temporal order to the general timing mechanisms for the perception of duration, temporal frequency, and synchrony.

  2. Duration estimates within a modality are integrated sub-optimally

    PubMed Central

    Cai, Ming Bo; Eagleman, David M.

    2015-01-01

    Perceived duration can be influenced by various properties of sensory stimuli. For example, visual stimuli of higher temporal frequency are perceived to last longer than those of lower temporal frequency. How does the brain form a representation of duration when each of two simultaneously presented stimuli influences perceived duration in different way? To answer this question, we investigated the perceived duration of a pair of dynamic visual stimuli of different temporal frequencies in comparison to that of a single visual stimulus of either low or high temporal frequency. We found that the duration representation of simultaneously occurring visual stimuli is best described by weighting the estimates of duration based on each individual stimulus. However, the weighting performance deviates from the prediction of statistically optimal integration. In addition, we provided a Bayesian account to explain a difference in the apparent sensitivity of the psychometric curves introduced by the order in which the two stimuli are displayed in a two-alternative forced-choice task. PMID:26321965

  3. 25 CFR 211.27 - Duration of leases.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR ENERGY AND MINERALS LEASING OF TRIBAL LANDS FOR MINERAL... duration shall be measured from the date of approval by the Secretary. (b) An oil and gas or geothermal... duration without actual production of oil, gas, or geothermal resources. Provided, that this extension does...

  4. 25 CFR 211.27 - Duration of leases.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR ENERGY AND MINERALS LEASING OF TRIBAL LANDS FOR MINERAL... duration shall be measured from the date of approval by the Secretary. (b) An oil and gas or geothermal... duration without actual production of oil, gas, or geothermal resources. Provided, that this extension does...

  5. 6 CFR 7.24 - Duration of classification.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 6 Domestic Security 1 2013-01-01 2013-01-01 false Duration of classification. 7.24 Section 7.24... INFORMATION Classified Information § 7.24 Duration of classification. (a) At the time of original classification, original classification authorities shall apply a date or event in which the information will be...

  6. 6 CFR 7.24 - Duration of classification.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 6 Domestic Security 1 2014-01-01 2014-01-01 false Duration of classification. 7.24 Section 7.24... INFORMATION Classified Information § 7.24 Duration of classification. (a) At the time of original classification, original classification authorities shall apply a date or event in which the information will be...

  7. 6 CFR 7.24 - Duration of classification.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 6 Domestic Security 1 2012-01-01 2012-01-01 false Duration of classification. 7.24 Section 7.24... INFORMATION Classified Information § 7.24 Duration of classification. (a) At the time of original classification, original classification authorities shall apply a date or event in which the information will be...

  8. 6 CFR 7.24 - Duration of classification.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 6 Domestic Security 1 2011-01-01 2011-01-01 false Duration of classification. 7.24 Section 7.24... INFORMATION Classified Information § 7.24 Duration of classification. (a) At the time of original classification, original classification authorities shall apply a date or event in which the information will be...

  9. 20 CFR 336.2 - Duration of normal unemployment benefits.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 1 2010-04-01 2010-04-01 false Duration of normal unemployment benefits. 336... UNEMPLOYMENT INSURANCE ACT DURATION OF NORMAL AND EXTENDED BENEFITS Normal Benefits § 336.2 Duration of normal unemployment benefits. (a) 130 compensable day limitation. A qualified employee who has satisfied the waiting...

  10. 20 CFR 336.2 - Duration of normal unemployment benefits.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 20 Employees' Benefits 1 2011-04-01 2011-04-01 false Duration of normal unemployment benefits. 336... UNEMPLOYMENT INSURANCE ACT DURATION OF NORMAL AND EXTENDED BENEFITS Normal Benefits § 336.2 Duration of normal unemployment benefits. (a) 130 compensable day limitation. A qualified employee who has satisfied the waiting...

  11. 20 CFR 336.2 - Duration of normal unemployment benefits.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 20 Employees' Benefits 1 2012-04-01 2012-04-01 false Duration of normal unemployment benefits. 336... UNEMPLOYMENT INSURANCE ACT DURATION OF NORMAL AND EXTENDED BENEFITS Normal Benefits § 336.2 Duration of normal unemployment benefits. (a) 130 compensable day limitation. A qualified employee who has satisfied the waiting...

  12. 20 CFR 336.2 - Duration of normal unemployment benefits.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 20 Employees' Benefits 1 2013-04-01 2012-04-01 true Duration of normal unemployment benefits. 336... UNEMPLOYMENT INSURANCE ACT DURATION OF NORMAL AND EXTENDED BENEFITS Normal Benefits § 336.2 Duration of normal unemployment benefits. (a) 130 compensable day limitation. A qualified employee who has satisfied the waiting...

  13. 20 CFR 336.2 - Duration of normal unemployment benefits.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 20 Employees' Benefits 1 2014-04-01 2012-04-01 true Duration of normal unemployment benefits. 336... UNEMPLOYMENT INSURANCE ACT DURATION OF NORMAL AND EXTENDED BENEFITS Normal Benefits § 336.2 Duration of normal unemployment benefits. (a) 130 compensable day limitation. A qualified employee who has satisfied the waiting...

  14. The Impact of Attention on Judgments of Frequency and Duration

    PubMed Central

    Winkler, Isabell; Glauer, Madlen; Betsch, Tilmann; Sedlmeier, Peter

    2015-01-01

    Previous studies that examined human judgments of frequency and duration found an asymmetrical relationship: While frequency judgments were quite accurate and independent of stimulus duration, duration judgments were highly dependent upon stimulus frequency. A potential explanation for these findings is that the asymmetry is moderated by the amount of attention directed to the stimuli. In the current experiment, participants' attention was manipulated in two ways: (a) intrinsically, by varying the type and arousal potential of the stimuli (names, low-arousal and high-arousal pictures), and (b) extrinsically, by varying the physical effort participants expended during the stimulus presentation (by lifting a dumbbell vs. relaxing the arm). Participants processed stimuli with varying presentation frequencies and durations and were subsequently asked to estimate the frequency and duration of each stimulus. Sensitivity to duration increased for pictures in general, especially when processed under physical effort. A large effect of stimulus frequency on duration judgments was obtained for all experimental conditions, but a similar large effect of presentation duration on frequency judgments emerged only in the conditions that could be expected to draw high amounts of attention to the stimuli: when pictures were judged under high physical effort. Almost no difference in the mutual impact of frequency and duration was obtained for low-arousal or high-arousal pictures. The mechanisms underlying the simultaneous processing of frequency and duration are discussed with respect to existing models derived from animal research. Options for the extension of such models to human processing of frequency and duration are suggested. PMID:26000712

  15. The impact of attention on judgments of frequency and duration.

    PubMed

    Winkler, Isabell; Glauer, Madlen; Betsch, Tilmann; Sedlmeier, Peter

    2015-01-01

    Previous studies that examined human judgments of frequency and duration found an asymmetrical relationship: While frequency judgments were quite accurate and independent of stimulus duration, duration judgments were highly dependent upon stimulus frequency. A potential explanation for these findings is that the asymmetry is moderated by the amount of attention directed to the stimuli. In the current experiment, participants' attention was manipulated in two ways: (a) intrinsically, by varying the type and arousal potential of the stimuli (names, low-arousal and high-arousal pictures), and (b) extrinsically, by varying the physical effort participants expended during the stimulus presentation (by lifting a dumbbell vs. relaxing the arm). Participants processed stimuli with varying presentation frequencies and durations and were subsequently asked to estimate the frequency and duration of each stimulus. Sensitivity to duration increased for pictures in general, especially when processed under physical effort. A large effect of stimulus frequency on duration judgments was obtained for all experimental conditions, but a similar large effect of presentation duration on frequency judgments emerged only in the conditions that could be expected to draw high amounts of attention to the stimuli: when pictures were judged under high physical effort. Almost no difference in the mutual impact of frequency and duration was obtained for low-arousal or high-arousal pictures. The mechanisms underlying the simultaneous processing of frequency and duration are discussed with respect to existing models derived from animal research. Options for the extension of such models to human processing of frequency and duration are suggested.

  16. Associations between sleep duration, sleep quality and diabetic retinopathy.

    PubMed

    Tan, Nicholas Y Q; Chew, Merwyn; Tham, Yih-Chung; Nguyen, Quang Duc; Yasuda, Masayuki; Cheng, Ching-Yu; Wong, Tien Yin; Sabanayagam, Charumathi

    2018-01-01

    Abnormal durations of sleep have been associated with risk of diabetes. However, it is not clear if sleep duration is associated with diabetic retinopathy (DR). In a cross-sectional study, we included 1,231 (Malay, n = 395; Indian, n = 836) adults (mean age 64.4 ± 9.0 years, 50.4% female) with diabetes from the second visit of two independent population-based cohort studies (2011-15) in Singapore. Self-reported habitual sleep duration was categorized as short (<6 h), normal (6≤ h <8), and long (≥8 h). Questionnaires were administered to detect risk of obstructive sleep apnea (OSA), excessive daytime sleepiness, and insomnia, all of which may indicate poor quality of sleep. The associations between sleep-related characteristics with moderate DR and vision-threatening DR (VTDR) were analysed using logistic regression models adjusted for potential confounders. Prevalence of moderate DR and VTDR in the study population were 10.5% and 6.3% respectively. The mean duration of sleep was 6.4 ± 1.5 h. Compared to normal sleep duration, both short and long sleep durations were associated with moderate DR with multivariable odds ratio (95% confidence interval) of 1.73 (1.03-2.89) and 2.17 (1.28-3.66) respectively. Long sleep duration (2.37 [1.16-4.89]), high risk of OSA (2.24 [1.09-4.75]), and excessive daytime sleepiness (3.27 [1.02-10.30]) were separately associated with VTDR. Sleep duration had a U-shaped association with moderate DR; long sleep duration, excessive daytime sleepiness and high risk of OSA were positively associated with VTDR.

  17. Early prediction of cardiac resynchronization therapy response by non-invasive electrocardiogram markers.

    PubMed

    Ortigosa, Nuria; Pérez-Roselló, Víctor; Donoso, Víctor; Osca, Joaquín; Martínez-Dolz, Luis; Fernández, Carmen; Galbis, Antonio

    2018-04-01

    Cardiac resynchronization therapy (CRT) is an effective treatment for those patients with severe heart failure. Regrettably, there are about one third of CRT "non-responders", i.e. patients who have undergone this form of device therapy but do not respond to it, which adversely affects the utility and cost-effectiveness of CRT. In this paper, we assess the ability of a novel surface ECG marker to predict CRT response. We performed a retrospective exploratory study of the ECG previous to CRT implantation in 43 consecutive patients with ischemic (17) or non-ischemic (26) cardiomyopathy. We extracted the QRST complexes (consisting of the QRS complex, the S-T segment, and the T wave) and obtained a measure of their energy by means of spectral analysis. This ECG marker showed statistically significant lower values for non-responder patients and, joint with the duration of QRS complexes (the current gold-standard to predict CRT response), the following performances: 86% accuracy, 88% sensitivity, and 80% specificity. In this manner, the proposed ECG marker may help clinicians to predict positive response to CRT in a non-invasive way, in order to minimize unsuccessful procedures.

  18. Perceived duration decreases with increasing eccentricity.

    PubMed

    Kliegl, Katrin M; Huckauf, Anke

    2014-07-01

    Previous studies examining the influence of stimulus location on temporal perception yield inhomogeneous and contradicting results. Therefore, the aim of the present study is to soundly examine the effect of stimulus eccentricity. In a series of five experiments, subjects compared the duration of foveal disks to disks presented at different retinal eccentricities on the horizontal meridian. The results show that the perceived duration of a visual stimulus declines with increasing eccentricity. The effect was replicated with various stimulus orders (Experiments 1-3), as well as with cortically magnified stimuli (Experiments 4-5), ruling out that the effect was merely caused by different cortical representation sizes. The apparent decreasing duration of stimuli with increasing eccentricity is discussed with respect to current models of time perception, the possible influence of visual attention and respective underlying physiological characteristics of the visual system. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. 42 CFR 488.454 - Duration of remedies.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Duration of remedies. 488.454 Section 488.454... Compliance for Long-Term Care Facilities with Deficiencies § 488.454 Duration of remedies. (a) Except as specified in paragraphs (b) and (d) of this section, alternative remedies continue until— (1) The facility...

  20. 42 CFR 488.454 - Duration of remedies.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Duration of remedies. 488.454 Section 488.454... Compliance for Long-Term Care Facilities with Deficiencies § 488.454 Duration of remedies. (a) Except as specified in paragraphs (b) and (d) of this section, alternative remedies continue until— (1) The facility...

  1. 27 CFR 19.679 - Duration of permit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... § 19.679 Duration of permit. The proprietor of an alcohol fuel plant may conduct the operations... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Duration of permit. 19.679 Section 19.679 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT...

  2. 14 CFR 133.13 - Duration of certificate.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Duration of certificate. 133.13 Section 133...-LOAD OPERATIONS Certification Rules § 133.13 Duration of certificate. Unless sooner surrendered..., as amended by Amdt. 133-7, 42 FR 32531, June 27, 1977; Amdt. 133-9, 51 FR 40707, Nov. 7, 1986] ...

  3. 27 CFR 478.49 - Duration of license.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2010-04-01 2010-04-01 false Duration of license. 478....49 Duration of license. The license entitles the person to whom issued to engage in the business or activity specified on the license, within the limitations of the Act and the regulations contained in this...

  4. Changes in apparent duration follow shifts in perceptual timing

    PubMed Central

    Bruno, Aurelio; Ayhan, Inci; Johnston, Alan

    2015-01-01

    It is well established that the apparent duration of moving visual objects is greater at higher as compared to slower speeds. Here we report the effects of acceleration and deceleration on the perceived duration of a drifting grating with average speed kept constant (10°/s).For acceleration, increasing the speed range progressively reduced perceived duration. The magnitude of apparent duration compression was determined by speed rather than temporal frequency and was proportional to speed range (independent of standard duration) rather than acceleration. The perceived duration reduction was also proportional to the standard length. The effects of increases and decreases in speed were highly asymmetric. Reducing speed through the interval induced a moderate increase in perceived duration. These results could not be explained by changes in apparent onset or offset or differences in perceived average speed between intervals containing increasing speed and intervals containing decreasing speed. Paradoxically, for intervals combining increasing speed and decreasing speed, compression only occurred when increasing speed occurred in the second half of the interval. We show that this pattern of results in the duration domain was concomitant with changes in the reported direction of apparent motion of Gaussian blobs, embedded in intervals of increasing or decreasing speed, that could be predicted from adaptive changes in the temporal impulse response function. We detected similar changes after flicker adaptation, suggesting that the two effects might be linked through changes in the temporal tuning of visual filters. PMID:26024450

  5. Duration of menopausal vasomotor symptoms over the menopause transition.

    PubMed

    Avis, Nancy E; Crawford, Sybil L; Greendale, Gail; Bromberger, Joyce T; Everson-Rose, Susan A; Gold, Ellen B; Hess, Rachel; Joffe, Hadine; Kravitz, Howard M; Tepper, Ping G; Thurston, Rebecca C

    2015-04-01

    The expected duration of menopausal vasomotor symptoms (VMS) is important to women making decisions about possible treatments. To determine total duration of frequent VMS (≥ 6 days in the previous 2 weeks) (hereafter total VMS duration) during the menopausal transition, to quantify how long frequent VMS persist after the final menstrual period (FMP) (hereafter post-FMP persistence), and to identify risk factors for longer total VMS duration and longer post-FMP persistence. The Study of Women's Health Across the Nation (SWAN) is a multiracial/multiethnic observational study of the menopausal transition among 3302 women enrolled at 7 US sites. From February 1996 through April 2013, women completed a median of 13 visits. Analyses included 1449 women with frequent VMS. Total VMS duration (in years) (hot flashes or night sweats) and post-FMP persistence (in years) into postmenopause. The median total VMS duration was 7.4 years. Among 881 women who experienced an observable FMP, the median post-FMP persistence was 4.5 years. Women who were premenopausal or early perimenopausal when they first reported frequent VMS had the longest total VMS duration (median, >11.8 years) and post-FMP persistence (median, 9.4 years). Women who were postmenopausal at the onset of VMS had the shortest total VMS duration (median, 3.4 years). Compared with women of other racial/ethnic groups, African American women reported the longest total VMS duration (median, 10.1 years). Additional factors related to longer duration of VMS (total VMS duration or post-FMP persistence) were younger age, lower educational level, greater perceived stress and symptom sensitivity, and higher depressive symptoms and anxiety at first report of VMS. Frequent VMS lasted more than 7 years during the menopausal transition for more than half of the women and persisted for 4.5 years after the FMP. Individual characteristics (eg, being premenopausal and having greater negative affective factors when first experiencing

  6. Short Sleep Duration in Middle Childhood: Risk Factors and Consequences

    PubMed Central

    Nixon, Gillian M.; Thompson, John M. D.; Han, Dug Yeo; Becroft, David M.; Clark, Phillipa M.; Robinson, Elizabeth; Waldie, Karen E.; Wild, Chris J.; Black, Peter N.; Mitchell, Edwin A.

    2008-01-01

    Study Objectives: To measure sleep duration in 7-year-old children; identify the determinants of sleep duration; and assess the association between short sleep duration and obesity, cognitive functioning, and behaviour. Design: Longitudinal study with disproportionate sampling of the participants. Setting: Community. Participants: 591 seven-year-old children, of whom 519 had complete sleep data. Interventions: Not applicable. Measurements: Sleep duration was assessed by actigraphy. Other measurements included height, weight, BMI, percentage body fat as assessed by bioimpedance assay, intelligence (WISC-III) and behaviour (Strengths & Difficulties questionnaire, parent and teachers Conners Rating Scales). Results: Mean time in bed according to parental report was 10.9 hours (SD 0.8). Mean sleep duration by actigraphy was 10.1 (SD 0.8) hours. In multivariable analysis, sleep duration was longer on weekdays vs. weekend nights (31.5 min, P = 0.002), in winter (40.5 min), autumn (31.1 min), and spring (14.8 min) compared with summer (P <0.0001), and in those with younger siblings (11.7 min, P = 0.03). Sleep duration was shorter when bedtime was after 21:00 (−41.1 min, P <0.0001). In multivariable analysis, sleep duration <9 hours was associated with being overweight/obese (BMI: OR = 3.32; 95% CI = 1.40, 7.87) with an increase of 3.34% body fat (P = 0.03), and this was not explained by physical activity or television watching. Short sleep duration was also associated with higher emotional lability scores (Conners Rating Scale Parent Form; P = 0.03). IQ (WISC-III) and attention deficit / hyperactivity disorder scores (both parent and teachers Conners Rating Scales) did not differ with sleep duration. Conclusions: Sleep duration in 7-year-old children varies considerably among individuals. The duration is affected by weekday, season, and having younger siblings. Importantly, short sleep duration was shown to be an independent risk factor for obesity/overweight. Citation

  7. Slow Wave Sleep and Long Duration Spaceflight

    NASA Technical Reports Server (NTRS)

    Whitmire, Alexandra; Orr, Martin; Arias, Diana; Rueger, Melanie; Johnston, Smith; Leveton, Lauren

    2012-01-01

    While ground research has clearly shown that preserving adequate quantities of sleep is essential for optimal health and performance, changes in the progression, order and /or duration of specific stages of sleep is also associated with deleterious outcomes. As seen in Figure 1, in healthy individuals, REM and Non-REM sleep alternate cyclically, with stages of Non-REM sleep structured chronologically. In the early parts of the night, for instance, Non-REM stages 3 and 4 (Slow Wave Sleep, or SWS) last longer while REM sleep spans shorter; as night progresses, the length of SWS is reduced as REM sleep lengthens. This process allows for SWS to establish precedence , with increases in SWS seen when recovering from sleep deprivation. SWS is indeed regarded as the most restorative portion of sleep. During SWS, physiological activities such as hormone secretion, muscle recovery, and immune responses are underway, while neurological processes required for long term learning and memory consolidation, also occur. The structure and duration of specific sleep stages may vary independent of total sleep duration, and changes in the structure and duration have been shown to be associated with deleterious outcomes. Individuals with narcolepsy enter sleep through REM as opposed to stage 1 of NREM. Disrupting slow wave sleep for several consecutive nights without reducing total sleep duration or sleep efficiency is associated with decreased pain threshold, increased discomfort, fatigue, and the inflammatory flare response in skin. Depression has been shown to be associated with a reduction of slow wave sleep and increased REM sleep. Given research that shows deleterious outcomes are associated with changes in sleep structure, it is essential to characterize and mitigate not only total sleep duration, but also changes in sleep stages.

  8. Stimulus Intensity and the Perception of Duration

    ERIC Educational Resources Information Center

    Matthews, William J.; Stewart, Neil; Wearden, John H.

    2011-01-01

    This article explores the widely reported finding that the subjective duration of a stimulus is positively related to its magnitude. In Experiments 1 and 2 we show that, for both auditory and visual stimuli, the effect of stimulus magnitude on the perception of duration depends upon the background: Against a high intensity background, weak stimuli…

  9. Evaluation of electrocardiographic parameters in patients with diabetes insipidus.

    PubMed

    Deniz, Ferhat; Kepez, Alper; Ay, Seyit Ahmet; Ergogan, Okan; Baskoy, Kamil; Guncıkan, Mustafa Nuri; Dogan, Zekeriya; Yonem, Arif

    2015-11-01

    There is limited data regarding the effect of altered serum osmolality on cardiac electrical activity. The aim of the present study is to evaluate the electrocardiographic (ECG) effects of diabetes insipidus (DI) and any related hyperosmolality in a population of young patients with DI and without any known cardiovascular disease or risk factors. Twelve-lead ECG's of 44 consecutive untreated young male patients (age: 21.8 ± 2.9 years) who had been referred to endocrinology clinic and diagnosed as DI based on water deprivation test were retrospectively evaluated. A total of 30 age-matched (21.9 ± 2.4 years) healthy males were selected as control group and ECG's of these controls were obtained for comparison with ECG's of DI patients. All ECG parameters were measured and compared. Duration of QRS complex was significantly shorter in patients with DI compared with controls (85.2 ± 12.0 vs. 94.0 ± 10.6 ms, p: 0.001). P wave dispersion (PWD) of patients with DI was significantly higher compared with controls (31.9 ± 9.9 vs. 26.5 ± 10.6 ms, p: 0.03) and it was significantly correlated with serum osmolality and serum sodium level (r = - 0.36, p: 0.02 and r: - 0.35, p: 0.02, respectively). DI patients without any cardiovascular disease or risk factors displayed significantly shorter QRS duration and increased p wave dispersion compared with controls.

  10. Time Course of Electrical Remodeling of Native Conduction After Cardiac Resynchronization Therapy and Its Impact on Clinical Outcome.

    PubMed

    Cvijić, Marta; Žižek, David; Antolič, Bor; Zupan, Igor

    2017-03-01

    Cardiac resynchronization therapy (CRT) induces structural and electrical remodeling (ER) in heart failure (HF) patients. Our aim was to assess time course of ER of native conduction and mechanical remodeling after CRT and impact of CRT-induced ER on clinical outcome. We prospectively included 62 patients (aged 66 ± 10 years). Echocardiographic and ECG parameters were measured at baseline and 1, 3, 6, 9, and 12 months after implantation. Biventricular pacing was temporary inhibited during each follow-up to record intrinsic ECG. ER was defined as a decrease in native pre-implantation QRS duration ≥10 ms. During follow-up HF hospitalizations, cardiovascular death and transplantation (combined end point) were recorded. There were significant changes in intrinsic ECG parameters during follow-up; the narrowing of QRS duration was already observed after 1 month (median 185 ms [interquartile range (IQR) 175-194] vs 180 ms [170-194]; P < .001). Left ventricular (LV) volumes decreased only after 3 months of CRT (median end-systolic volume 167 mL [137-206] vs 140 mL [112-196]; P < .001). Only patients with ER (n = 24) exhibited significant mechanical remodeling and showed superior survival free from the combined end point compared with patients without ER (log-rank P = .028). Electrical remodeling of native conduction precedes detectable left ventricular structural changes after CRT. ER of native conduction is associated with better clinical outcome following CRT. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Left Ventricular Lead Placement Targeted at the Latest Activated Site Guided by Electrophysiological Mapping in Coronary Sinus Branches Improves Response to Cardiac Resynchronization Therapy.

    PubMed

    Liang, Yanchun; Yu, Haibo; Zhou, Weiwei; Xu, Guoqing; Sun, Y I; Liu, Rong; Wang, Zulu; Han, Yaling

    2015-12-01

    Electrophysiological mapping (EPM) in coronary sinus (CS) branches is feasible for guiding LV lead placement to the optimal, latest activated site at cardiac resynchronization therapy (CRT) procedures. However, whether this procedure optimizes the response to CRT has not been demonstrated. This study was to evaluate effects of targeting LV lead at the latest activated site guided by EPM during CRT. Seventy-six consecutive patients with advanced heart failure who were referred for CRT were divided into mapping (MG) and control groups (CG). In MG, the LV lead, also used as a mapping bipolar electrode, was placed at the latest activated site determined by EPM in CS branches. In CG, conventional CRT procedure was performed. Patients were followed for 6 months after CRT. Baseline characteristics were comparable between the 2 groups. In MG (n = 29), EPM was successfully performed in 85 of 91 CS branches during CRT. A LV lead was successfully placed at the latest activated site guided by EPM in 27 (93.1%) patients. Compared with CG (n = 47), MG had a significantly higher rate (86.2% vs. 63.8%, P = 0.039) of response (>15% reduction in LV end-systolic volume) to CRT, a higher percentage of patients with clinical improvement of ≥2 NYHA functional classes (72.4% vs. 44.7%, P = 0.032), and a shorter QRS duration (P = 0.004). LV lead placed at the latest activated site guided by EPM resulted in a significantly greater CRT response, and a shorter QRS duration. © 2015 Wiley Periodicals, Inc.

  12. Short sleep duration among workers--United States, 2010.

    PubMed

    2012-04-27

    Insufficient sleep can have serious and sometimes fatal consequences for fatigued workers and others around them. For example, an estimated 20% of vehicle crashes are linked to drowsy driving. The National Sleep Foundation recommends that healthy adults sleep 7-9 hours per day. To assess the prevalence of short sleep duration among workers, CDC analyzed data from the 2010 National Health Interview Survey (NHIS). The analysis compared sleep duration by age group, race/ethnicity, sex, marital status, education, and employment characteristics. Overall, 30.0% of civilian employed U.S. adults (approximately 40.6 million workers) reported an average sleep duration of ≤6 hours per day. The prevalence of short sleep duration (≤6 hours per day) varied by industry of employment (range: 24.1%-41.6%), with a significantly higher rate of short sleep duration among workers in manufacturing (34.1%) compared with all workers combined. Among all workers, those who usually worked the night shift had a much higher prevalence of short sleep duration (44.0%, representing approximately 2.2 million night shift workers) than those who worked the day shift (28.8%, representing approximately 28.3 million day shift workers). An especially high prevalence of short sleep duration was reported by night shift workers in the transportation and warehousing (69.7%) and health-care and social assistance (52.3%) industries. Targeted interventions, such as evidence-based shift system designs that improve sleep opportunities and evidence-based training programs on sleep and working hours tailored for managers and employees, should be implemented to protect the health and safety of workers, their coworkers, and the public.

  13. Key-peck durations under behavioral contrast and differential reinforcement

    PubMed Central

    Whipple, William R.; Fantino, Edmund

    1980-01-01

    Pigeons were maintained on a multiple schedule in which both components were variable-interval one-minute schedules. When they were switched to a condition in which one component was extinction, behavioral contrast was observed. The median durations of the key pecks in the unchanged component did not decrease in size. The results are incompatible with a theory of behavioral contrast which considers the added pecks to be short-duration responses. In a second experiment, pigeons were required to emit short-duration key pecks in one component of a multiple schedule, and long-duration pecks in the other. Two of three pigeons learned to emit responses appropriate to the requirements of the component in effect, suggesting that the duration of the key-peck response is sensitive to differential reinforcement. PMID:16812185

  14. Conditional probability of rainfall extremes across multiple durations

    NASA Astrophysics Data System (ADS)

    Le, Phuong Dong; Leonard, Michael; Westra, Seth

    2017-04-01

    The conditional probability that extreme rainfall will occur at one location given that it is occurring at another location is critical in engineering design and management circumstances including planning of evacuation routes and the sitting of emergency infrastructure. A challenge with this conditional simulation is that in many situations the interest is not so much the conditional distributions of rainfall of the same duration at two locations, but rather the conditional distribution of flooding in two neighbouring catchments, which may be influenced by rainfall of different critical durations. To deal with this challenge, a model that can consider both spatial and duration dependence of extremes is required. The aim of this research is to develop a model that can take account both spatial dependence and duration dependence into the dependence structure of extreme rainfalls. To achieve this aim, this study is a first attempt at combining extreme rainfall for multiple durations within a spatial extreme model framework based on max-stable process theory. Max-stable processes provide a general framework for modelling multivariate extremes with spatial dependence for just a single duration extreme rainfall. To achieve dependence across multiple timescales, this study proposes a new approach that includes addition elements representing duration dependence of extremes to the covariance matrix of max-stable model. To improve the efficiency of calculation, a re-parameterization proposed by Koutsoyiannis et al. (1998) is used to reduce the number of parameters necessary to be estimated. This re-parameterization enables the GEV parameters to be represented as a function of timescale. A stepwise framework has been adopted to achieve the overall aims of this research. Firstly, the re-parameterization is used to define a new set of common parameters for marginal distribution across multiple durations. Secondly, spatial interpolation of the new parameter set is used to

  15. Large size self-assembled quantum rings: quantum size effect and modulation on the surface diffusion.

    PubMed

    Tong, Cunzhu; Yoon, Soon Fatt; Wang, Lijun

    2012-09-24

    We demonstrate experimentally the submicron size self-assembled (SA) GaAs quantum rings (QRs) by quantum size effect (QSE). An ultrathin In0.1 Ga0.9As layer with different thickness is deposited on the GaAs to modulate the surface nucleus diffusion barrier, and then the SA QRs are grown. It is found that the density of QRs is affected significantly by the thickness of inserted In0.1 Ga0.9As, and the diffusion barrier modulation reflects mainly on the first five monolayer . The physical mechanism behind is discussed. The further analysis shows that about 160 meV decrease in diffusion barrier can be achieved, which allows the SA QRs with density of as low as one QR per 6 μm2. Finally, the QRs with diameters of 438 nm and outer diameters of 736 nm are fabricated using QSE.

  16. Maternal distress and intended breastfeeding duration.

    PubMed

    Rondó, Patricia H C; Souza, Márcia R

    2007-03-01

    To evaluate the associations between maternal psychological status and intended breastfeeding duration. A total of 852 pregnant women who attended antenatal care between September 1997 and August 2000 in 12 health units and five hospitals in Jundiaí city, Brazil, were included in the study. Psychological measures (stress and distress) were obtained at a gestational age from 30 to 36 weeks, using standardized scales, questionnaires and inventories. Psychological factors specifically related to breastfeeding assessed their worries, concerns, and support when breastfeeding. Multiple linear regression analysis identified the associations between the outcome "intended duration of breastfeeding" and psychological status of the mothers, controlling for toxic exposure, socioeconomic, demographic, obstetric and nutritional factors. There were negative associations between the outcome and distress, "concerned about body's changes", and work outside home, and a positive association between the outcome and marital status (p < or = 0.03). Early identification of distress in pregnant women and a more attentive encouragement to breastfeed is probably one of the steps to improve intended breastfeeding duration.

  17. Extended-duration versus short-duration pharmacological thromboprophylaxis in acutely Ill hospitalized medical patients: a systematic review and meta-analysis of randomized controlled trials.

    PubMed

    Liew, Aaron Y L; Piran, Siavash; Eikelboom, John W; Douketis, James D

    2017-04-01

    Extended-duration pharmacological thromboprophylaxis, for at least 28 days, is effective for the prevention of symptomatic venous thromboembolism (VTE) in high-risk surgical patients but is of uncertain benefit in hospitalized medical patients. We aimed to evaluate the efficacy and safety of extended-duration thromboprophylaxis in hospitalized medical patients. We conducted a systematic PubMed, Medline and EMBASE literature search until June 2016 and a meta-analysis of randomized controlled trials which compared extended-duration with short-duration thromboprophylaxis in hospitalized medical patients. Four randomized controlled trials comparing extended-duration prophylaxis (24-47 days) with short-duration prophylaxis (6-14 days) in a total of 34,068 acutely ill hospitalized medical patients were included. When compared with short-duration prophylaxis, extended-duration prophylaxis was associated with a decrease in symptomatic proximal or distal deep vein thrombosis (DVT) [relative risk (RR) = 0.52; 95% confidence interval (Cl): 0.35-0.77: p = 0.001; absolute risk reduction (ARR) = 0.32%, number needed to treat (NNT) = 313], and symptomatic non-fatal pulmonary embolism (RR = 0.61; 95% Cl 0.38-0.99: p = 0.04; ARR = 0.16%; NNT = 625), an increase in major bleeding (RR = 2.08; 95% Cl 1.50-2.90: p < 0.0001, absolute risk increase = 0.41%, number needed to harm = 244), and no significant reduction in VTE-related mortality (RR = 0.69; 95% Cl 0.45-1.06: p = 0.09) or all-cause mortality (RR = 1.00; 95% CI 0.89-1.12; p = 0.95). There was heterogeneity for major bleeding due to results from the APEX trial (no difference between betrixaban and enoxaparin). Compared with short-duration thromboprophylaxis, extended-duration treatment reduces the risk for symptomatic DVT and non-fatal pulmonary embolism. Extended treatment with apixaban, enoxaparin and rivaroxaban but not betrixaban increases the risk for major

  18. The Cox proportional Hazard model on duration of birth process

    NASA Astrophysics Data System (ADS)

    Wuryandari, Triastuti; Haryatmi Kartiko, Sri; Danardono

    2018-05-01

    The duration of birth process, which is measured from the birth sign until baby born, is one important factor to the whole outcome of delivery process. There is a method of birth process that given relaxing and gentle treatment to the mother caled as gentlebirth. Gentlebirth is a method of birth process that combines brain science, birth science and technology to empower positive birth without pain. However the effect of method to the duration of birth process is still need empirical investigations. Therefore, the objective of this paper is to analyze the duration of birth process using the appropriate statistical methods for durational data, survival data or time to event data. Since there are many variables or factor that may affect the duration, a regression model is considerated. The flexibility of the Cox Proportional Hazard Model in the sense that there is no distributional assumption required, makes the Cox Model as the appropriate model and method to analyze the duration birth process. It is concluded that the Gentlebirth method affects on duration of birth process, with Hazard Ratio of 2.073, showing that the duration of birth process with gentlebirth method is faster than the other method.

  19. A systematic approach to designing reliable VV optimization methodology: assessment of internal validity of echocardiographic, electrocardiographic and haemodynamic optimization of cardiac resynchronization therapy.

    PubMed

    Kyriacou, Andreas; Li Kam Wa, Matthew E; Pabari, Punam A; Unsworth, Beth; Baruah, Resham; Willson, Keith; Peters, Nicholas S; Kanagaratnam, Prapa; Hughes, Alun D; Mayet, Jamil; Whinnett, Zachary I; Francis, Darrel P

    2013-08-10

    In atrial fibrillation (AF), VV optimization of biventricular pacemakers can be examined in isolation. We used this approach to evaluate internal validity of three VV optimization methods by three criteria. Twenty patients (16 men, age 75 ± 7) in AF were optimized, at two paced heart rates, by LVOT VTI (flow), non-invasive arterial pressure, and ECG (minimizing QRS duration). Each optimization method was evaluated for: singularity (unique peak of function), reproducibility of optimum, and biological plausibility of the distribution of optima. The reproducibility (standard deviation of the difference, SDD) of the optimal VV delay was 10 ms for pressure, versus 8 ms (p=ns) for QRS and 34 ms (p<0.01) for flow. Singularity of optimum was 85% for pressure, 63% for ECG and 45% for flow (Chi(2)=10.9, p<0.005). The distribution of pressure optima was biologically plausible, with 80% LV pre-excited (p=0.007). The distributions of ECG (55% LV pre-excitation) and flow (45% LV pre-excitation) optima were no different to random (p=ns). The pressure-derived optimal VV delay is unaffected by the paced rate: SDD between slow and fast heart rate is 9 ms, no different from the reproducibility SDD at both heart rates. Using non-invasive arterial pressure, VV delay optimization by parabolic fitting is achievable with good precision, satisfying all 3 criteria of internal validity. VV optimum is unaffected by heart rate. Neither QRS minimization nor LVOT VTI satisfy all validity criteria, and therefore seem weaker candidate modalities for VV optimization. AF, unlinking interventricular from atrioventricular delay, uniquely exposes resynchronization concepts to experimental scrutiny. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.