Sample records for quality assessment method

  1. A new method for water quality assessment: by harmony degree equation.

    PubMed

    Zuo, Qiting; Han, Chunhui; Liu, Jing; Ma, Junxia

    2018-02-22

    Water quality assessment is an important basic work in the development, utilization, management, and protection of water resources, and also a prerequisite for water safety. In this paper, the harmony degree equation (HDE) was introduced into the research of water quality assessment, and a new method for water quality assessment was proposed according to the HDE: by harmony degree equation (WQA-HDE). First of all, the calculation steps and ideas of this method were described in detail, and then, this method with some other important methods of water quality assessment (single factor assessment method, mean-type comprehensive index assessment method, and multi-level gray correlation assessment method) were used to assess the water quality of the Shaying River (the largest tributary of the Huaihe in China). For this purpose, 2 years (2013-2014) dataset of nine water quality variables covering seven monitoring sites, and approximately 189 observations were used to compare and analyze the characteristics and advantages of the new method. The results showed that the calculation steps of WQA-HDE are similar to the comprehensive assessment method, and WQA-HDE is more operational comparing with the results of other water quality assessment methods. In addition, this new method shows good flexibility by setting the judgment criteria value HD 0 of water quality; when HD 0  = 0.8, the results are closer to reality, and more realistic and reliable. Particularly, when HD 0  = 1, the results of WQA-HDE are consistent with the single factor assessment method, both methods are subject to the most stringent "one vote veto" judgment condition. So, WQA-HDE is a composite method that combines the single factor assessment and comprehensive assessment. This research not only broadens the research field of theoretical method system of harmony theory but also promotes the unity of water quality assessment method and can be used for reference in other comprehensive assessment.

  2. Application of Nemerow Index Method and Integrated Water Quality Index Method in Water Quality Assessment of Zhangze Reservoir

    NASA Astrophysics Data System (ADS)

    Zhang, Qian; Feng, Minquan; Hao, Xiaoyan

    2018-03-01

    [Objective] Based on the water quality historical data from the Zhangze Reservoir from the last five years, the water quality was assessed by the integrated water quality identification index method and the Nemerow pollution index method. The results of different evaluation methods were analyzed and compared and the characteristics of each method were identified.[Methods] The suitability of the water quality assessment methods were compared and analyzed, based on these results.[Results] the water quality tended to decrease over time with 2016 being the year with the worst water quality. The sections with the worst water quality were the southern and northern sections.[Conclusion] The results produced by the traditional Nemerow index method fluctuated greatly in each section of water quality monitoring and therefore could not effectively reveal the trend of water quality at each section. The combination of qualitative and quantitative measures of the comprehensive pollution index identification method meant it could evaluate the degree of water pollution as well as determine that the river water was black and odorous. However, the evaluation results showed that the water pollution was relatively low.The results from the improved Nemerow index evaluation were better as the single indicators and evaluation results are in strong agreement; therefore the method is able to objectively reflect the water quality of each water quality monitoring section and is more suitable for the water quality evaluation of the reservoir.

  3. A review of data quality assessment methods for public health information systems.

    PubMed

    Chen, Hong; Hailey, David; Wang, Ning; Yu, Ping

    2014-05-14

    High quality data and effective data quality assessment are required for accurately evaluating the impact of public health interventions and measuring public health outcomes. Data, data use, and data collection process, as the three dimensions of data quality, all need to be assessed for overall data quality assessment. We reviewed current data quality assessment methods. The relevant study was identified in major databases and well-known institutional websites. We found the dimension of data was most frequently assessed. Completeness, accuracy, and timeliness were the three most-used attributes among a total of 49 attributes of data quality. The major quantitative assessment methods were descriptive surveys and data audits, whereas the common qualitative assessment methods were interview and documentation review. The limitations of the reviewed studies included inattentiveness to data use and data collection process, inconsistency in the definition of attributes of data quality, failure to address data users' concerns and a lack of systematic procedures in data quality assessment. This review study is limited by the coverage of the databases and the breadth of public health information systems. Further research could develop consistent data quality definitions and attributes. More research efforts should be given to assess the quality of data use and the quality of data collection process.

  4. A Review of Data Quality Assessment Methods for Public Health Information Systems

    PubMed Central

    Chen, Hong; Hailey, David; Wang, Ning; Yu, Ping

    2014-01-01

    High quality data and effective data quality assessment are required for accurately evaluating the impact of public health interventions and measuring public health outcomes. Data, data use, and data collection process, as the three dimensions of data quality, all need to be assessed for overall data quality assessment. We reviewed current data quality assessment methods. The relevant study was identified in major databases and well-known institutional websites. We found the dimension of data was most frequently assessed. Completeness, accuracy, and timeliness were the three most-used attributes among a total of 49 attributes of data quality. The major quantitative assessment methods were descriptive surveys and data audits, whereas the common qualitative assessment methods were interview and documentation review. The limitations of the reviewed studies included inattentiveness to data use and data collection process, inconsistency in the definition of attributes of data quality, failure to address data users’ concerns and a lack of systematic procedures in data quality assessment. This review study is limited by the coverage of the databases and the breadth of public health information systems. Further research could develop consistent data quality definitions and attributes. More research efforts should be given to assess the quality of data use and the quality of data collection process. PMID:24830450

  5. Towards a Quality Assessment Method for Learning Preference Profiles in Negotiation

    NASA Astrophysics Data System (ADS)

    Hindriks, Koen V.; Tykhonov, Dmytro

    In automated negotiation, information gained about an opponent's preference profile by means of learning techniques may significantly improve an agent's negotiation performance. It therefore is useful to gain a better understanding of how various negotiation factors influence the quality of learning. The quality of learning techniques in negotiation are typically assessed indirectly by means of comparing the utility levels of agreed outcomes and other more global negotiation parameters. An evaluation of learning based on such general criteria, however, does not provide any insight into the influence of various aspects of negotiation on the quality of the learned model itself. The quality may depend on such aspects as the domain of negotiation, the structure of the preference profiles, the negotiation strategies used by the parties, and others. To gain a better understanding of the performance of proposed learning techniques in the context of negotiation and to be able to assess the potential to improve the performance of such techniques a more systematic assessment method is needed. In this paper we propose such a systematic method to analyse the quality of the information gained about opponent preferences by learning in single-instance negotiations. The method includes measures to assess the quality of a learned preference profile and proposes an experimental setup to analyse the influence of various negotiation aspects on the quality of learning. We apply the method to a Bayesian learning approach for learning an opponent's preference profile and discuss our findings.

  6. Methods and dimensions of electronic health record data quality assessment: enabling reuse for clinical research

    PubMed Central

    Weng, Chunhua

    2013-01-01

    Objective To review the methods and dimensions of data quality assessment in the context of electronic health record (EHR) data reuse for research. Materials and methods A review of the clinical research literature discussing data quality assessment methodology for EHR data was performed. Using an iterative process, the aspects of data quality being measured were abstracted and categorized, as well as the methods of assessment used. Results Five dimensions of data quality were identified, which are completeness, correctness, concordance, plausibility, and currency, and seven broad categories of data quality assessment methods: comparison with gold standards, data element agreement, data source agreement, distribution comparison, validity checks, log review, and element presence. Discussion Examination of the methods by which clinical researchers have investigated the quality and suitability of EHR data for research shows that there are fundamental features of data quality, which may be difficult to measure, as well as proxy dimensions. Researchers interested in the reuse of EHR data for clinical research are recommended to consider the adoption of a consistent taxonomy of EHR data quality, to remain aware of the task-dependence of data quality, to integrate work on data quality assessment from other fields, and to adopt systematic, empirically driven, statistically based methods of data quality assessment. Conclusion There is currently little consistency or potential generalizability in the methods used to assess EHR data quality. If the reuse of EHR data for clinical research is to become accepted, researchers should adopt validated, systematic methods of EHR data quality assessment. PMID:22733976

  7. Development and application of a statistical quality assessment method for dense-graded mixes.

    DOT National Transportation Integrated Search

    2004-08-01

    This report describes the development of the statistical quality assessment method and the procedure for mapping the measures obtained from the quality assessment method to a composite pay factor. The application to dense-graded mixes is demonstrated...

  8. Methods for assessing the quality of data in public health information systems: a critical review.

    PubMed

    Chen, Hong; Yu, Ping; Hailey, David; Wang, Ning

    2014-01-01

    The quality of data in public health information systems can be ensured by effective data quality assessment. In order to conduct effective data quality assessment, measurable data attributes have to be precisely defined. Then reliable and valid measurement methods for data attributes have to be used to measure each attribute. We conducted a systematic review of data quality assessment methods for public health using major databases and well-known institutional websites. 35 studies were eligible for inclusion in the study. A total of 49 attributes of data quality were identified from the literature. Completeness, accuracy and timeliness were the three most frequently assessed attributes of data quality. Most studies directly examined data values. This is complemented by exploring either data users' perception or documentation quality. However, there are limitations of current data quality assessment methods: a lack of consensus on attributes measured; inconsistent definition of the data quality attributes; a lack of mixed methods for assessing data quality; and inadequate attention to reliability and validity. Removal of these limitations is an opportunity for further improvement.

  9. River Pollution: Part II. Biological Methods for Assessing Water Quality.

    ERIC Educational Resources Information Center

    Openshaw, Peter

    1984-01-01

    Discusses methods used in the biological assessment of river quality and such indicators of clean and polluted waters as the Trent Biotic Index, Chandler Score System, and species diversity indexes. Includes a summary of a river classification scheme based on quality criteria related to water use. (JN)

  10. Models and Methods of Aggregating Linguistic Information in Multi-criteria Hierarchical Quality Assessment Systems

    NASA Astrophysics Data System (ADS)

    Azarnova, T. V.; Titova, I. A.; Barkalov, S. A.

    2018-03-01

    The article presents an algorithm for obtaining an integral assessment of the quality of an organization from the perspective of customers, based on the method of aggregating linguistic information on a multilevel hierarchical system of quality assessment. The algorithm is of a constructive nature, it provides not only the possibility of obtaining an integral evaluation, but also the development of a quality improvement strategy based on the method of linguistic decomposition, which forms the minimum set of areas of work with clients whose quality change will allow obtaining the required level of integrated quality assessment.

  11. Massive integration of diverse protein quality assessment methods to improve template based modeling in CASP11

    PubMed Central

    Cao, Renzhi; Bhattacharya, Debswapna; Adhikari, Badri; Li, Jilong; Cheng, Jianlin

    2015-01-01

    Model evaluation and selection is an important step and a big challenge in template-based protein structure prediction. Individual model quality assessment methods designed for recognizing some specific properties of protein structures often fail to consistently select good models from a model pool because of their limitations. Therefore, combining multiple complimentary quality assessment methods is useful for improving model ranking and consequently tertiary structure prediction. Here, we report the performance and analysis of our human tertiary structure predictor (MULTICOM) based on the massive integration of 14 diverse complementary quality assessment methods that was successfully benchmarked in the 11th Critical Assessment of Techniques of Protein Structure prediction (CASP11). The predictions of MULTICOM for 39 template-based domains were rigorously assessed by six scoring metrics covering global topology of Cα trace, local all-atom fitness, side chain quality, and physical reasonableness of the model. The results show that the massive integration of complementary, diverse single-model and multi-model quality assessment methods can effectively leverage the strength of single-model methods in distinguishing quality variation among similar good models and the advantage of multi-model quality assessment methods of identifying reasonable average-quality models. The overall excellent performance of the MULTICOM predictor demonstrates that integrating a large number of model quality assessment methods in conjunction with model clustering is a useful approach to improve the accuracy, diversity, and consequently robustness of template-based protein structure prediction. PMID:26369671

  12. [FQA: A method for floristic quality assessment based on conservatism of plant species].

    PubMed

    Cao, Li Juan; He, Ping; Wang, Mi; Xui, Jie; Ren, Ying

    2018-04-01

    FQA, which uses the conservatism of plant species for particular habitats and the species richness of plant communities, is a rapid method for the assessment of habitat quality. This method is based on species composition of quadrats and coefficients of conservatism for species which assigned by experts. Floristic Quality Index (FQI) that reflects vegetation integrity and degradation of a site can be calculated by a simple formula and be used for space-time comparison of habitat quality. It has been widely used in more than ten countries including the United States and Canada. This paper presented the principle, calculation formulas and application cases of this method, with the aim to provide a simple, repeatable and comparable method to assess habitat quality for ecological managers and researchers.

  13. Massive integration of diverse protein quality assessment methods to improve template based modeling in CASP11.

    PubMed

    Cao, Renzhi; Bhattacharya, Debswapna; Adhikari, Badri; Li, Jilong; Cheng, Jianlin

    2016-09-01

    Model evaluation and selection is an important step and a big challenge in template-based protein structure prediction. Individual model quality assessment methods designed for recognizing some specific properties of protein structures often fail to consistently select good models from a model pool because of their limitations. Therefore, combining multiple complimentary quality assessment methods is useful for improving model ranking and consequently tertiary structure prediction. Here, we report the performance and analysis of our human tertiary structure predictor (MULTICOM) based on the massive integration of 14 diverse complementary quality assessment methods that was successfully benchmarked in the 11th Critical Assessment of Techniques of Protein Structure prediction (CASP11). The predictions of MULTICOM for 39 template-based domains were rigorously assessed by six scoring metrics covering global topology of Cα trace, local all-atom fitness, side chain quality, and physical reasonableness of the model. The results show that the massive integration of complementary, diverse single-model and multi-model quality assessment methods can effectively leverage the strength of single-model methods in distinguishing quality variation among similar good models and the advantage of multi-model quality assessment methods of identifying reasonable average-quality models. The overall excellent performance of the MULTICOM predictor demonstrates that integrating a large number of model quality assessment methods in conjunction with model clustering is a useful approach to improve the accuracy, diversity, and consequently robustness of template-based protein structure prediction. Proteins 2016; 84(Suppl 1):247-259. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  14. A recreation quality rapid assessment method for visitor capacity management

    Treesearch

    Kenneth Chilman; Stuart Schneider; Les Wadzinski

    2007-01-01

    A rapid assessment method for inexpensively obtaining representative samples of place-specific visitor numbers and perceptions of visit quality was tested on Niobrara National Scenic River (NSR). Similar tests have been done on national forest areas in Indiana and Illinois. The data are used in meetings focusing on visitor capacity management. The rapid assessment...

  15. Video quality assessment method motivated by human visual perception

    NASA Astrophysics Data System (ADS)

    He, Meiling; Jiang, Gangyi; Yu, Mei; Song, Yang; Peng, Zongju; Shao, Feng

    2016-11-01

    Research on video quality assessment (VQA) plays a crucial role in improving the efficiency of video coding and the performance of video processing. It is well acknowledged that the motion energy model generates motion energy responses in a middle temporal area by simulating the receptive field of neurons in V1 for the motion perception of the human visual system. Motivated by the biological evidence for the visual motion perception, a VQA method is proposed in this paper, which comprises the motion perception quality index and the spatial index. To be more specific, the motion energy model is applied to evaluate the temporal distortion severity of each frequency component generated from the difference of Gaussian filter bank, which produces the motion perception quality index, and the gradient similarity measure is used to evaluate the spatial distortion of the video sequence to get the spatial quality index. The experimental results of the LIVE, CSIQ, and IVP video databases demonstrate that the random forests regression technique trained by the generated quality indices is highly correspondent to human visual perception and has many significant improvements than comparable well-performing methods. The proposed method has higher consistency with subjective perception and higher generalization capability.

  16. Comparative analysis of water quality and toxicity assessment methods for urban highway runoff.

    PubMed

    Chen, Rui-Hong; Li, Fei-Peng; Zhang, Hai-Ping; Jiang, Yue; Mao, Ling-Chen; Wu, Ling-Ling; Chen, Ling

    2016-05-15

    In this study, comparative analyses of highway runoff samples obtained from seventeen storm events have been conducted between the traditional water quality assessment method and biotoxicity tests, using zebrafish (Danio rerio) embryos and luminous bacteria (Vibrio qinghaiensis. Q67) to provide useful information for ecotoxicity assessment of urban highway runoff. The study results showed that the Nemerow pollution index based on US EPA recommended Criteria Maximum Concentrations (CMC) (as traditional water quality assessment method) had no significant correlation with luminous bacteria acute toxicity test results, while significant correlation has been observed with two indicators of 72 hpf (hours post fertilization) hour hatching rate and 96 hpf abnormality rate from the toxicity test with zebrafish embryos. It is therefore concluded that the level of mixture toxicity of highway runoff could not be adequately measured by the Nemerow assessment method. Moreover, the key pollutants identified from the water quality assessment and from the biotoxicity evaluation were not consistent. For biotoxic effect evaluation of highway runoff, three indexes were found to be sensitive, i.e. 24 hpf lethality and 96 hpf abnormality of zebrafish embryos, as well as the inhibition rate for luminous bacteria Q67. It is therefore recommended that these indexes could be incorporated into the traditional Nemerow method to provide a more reasonable evaluation of the highway runoff quality and ecotoxicity. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. A Systematic Review of Methods for Evaluating Rating Quality in Language Assessment

    ERIC Educational Resources Information Center

    Wind, Stefanie A.; Peterson, Meghan E.

    2018-01-01

    The use of assessments that require rater judgment (i.e., rater-mediated assessments) has become increasingly popular in high-stakes language assessments worldwide. Using a systematic literature review, the purpose of this study is to identify and explore the dominant methods for evaluating rating quality within the context of research on…

  18. A novel no-reference objective stereoscopic video quality assessment method based on visual saliency analysis

    NASA Astrophysics Data System (ADS)

    Yang, Xinyan; Zhao, Wei; Ye, Long; Zhang, Qin

    2017-07-01

    This paper proposes a no-reference objective stereoscopic video quality assessment method with the motivation that making the effect of objective experiments close to that of subjective way. We believe that the image regions with different visual salient degree should not have the same weights when designing an assessment metric. Therefore, we firstly use GBVS algorithm to each frame pairs and separate both the left and right viewing images into the regions with strong, general and week saliency. Besides, local feature information like blockiness, zero-crossing and depth are extracted and combined with a mathematical model to calculate a quality assessment score. Regions with different salient degree are assigned with different weights in the mathematical model. Experiment results demonstrate the superiority of our method compared with the existed state-of-the-art no-reference objective Stereoscopic video quality assessment methods.

  19. Strapdown Airborne Gravimetry Quality Assessment Method Based on Single Survey Line Data: A Study by SGA-WZ02 Gravimeter

    PubMed Central

    Wu, Meiping; Cao, Juliang; Zhang, Kaidong; Cai, Shaokun; Yu, Ruihang

    2018-01-01

    Quality assessment is an important part in the strapdown airborne gravimetry. Root mean square error (RMSE) evaluation method is a classical way to evaluate the gravimetry quality, but classical evaluation methods are preconditioned by extra flight or reference data. Thus, a method, which is able to largely conquer the premises of classical quality assessment methods and can be used in single survey line, has been developed in this paper. According to theoretical analysis, the method chooses the stability of two horizontal attitude angles, horizontal specific force and vertical specific force as the determinants of quality assessment method. The actual data, collected by SGA-WZ02 from 13 flights 21 lines in certain survey, was used to build the model and elaborate the method. To substantiate the performance of the quality assessment model, the model is applied in extra repeat line flights from two surveys. Compared with internal RMSE, standard deviation of assessment residuals are 0.23 mGal and 0.16 mGal in two surveys, which shows that the quality assessment method is reliable and stricter. The extra flights are not necessary by specially arranging the route of flights. The method, summarized from SGA-WZ02, is a feasible approach to assess gravimetry quality using single line data and is also suitable for other strapdown gravimeters. PMID:29373535

  20. Revised Methods for Characterizing Stream Habitat in the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Fitzpatrick, Faith A.; Waite, Ian R.; D'Arconte, Patricia J.; Meador, Michael R.; Maupin, Molly A.; Gurtz, Martin E.

    1998-01-01

    Stream habitat is characterized in the U.S. Geological Survey's National Water-Quality Assessment (NAWQA) Program as part of an integrated physical, chemical, and biological assessment of the Nation's water quality. The goal of stream habitat characterization is to relate habitat to other physical, chemical, and biological factors that describe water-quality conditions. To accomplish this goal, environmental settings are described at sites selected for water-quality assessment. In addition, spatial and temporal patterns in habitat are examined at local, regional, and national scales. This habitat protocol contains updated methods for evaluating habitat in NAWQA Study Units. Revisions are based on lessons learned after 6 years of applying the original NAWQA habitat protocol to NAWQA Study Unit ecological surveys. Similar to the original protocol, these revised methods for evaluating stream habitat are based on a spatially hierarchical framework that incorporates habitat data at basin, segment, reach, and microhabitat scales. This framework provides a basis for national consistency in collection techniques while allowing flexibility in habitat assessment within individual Study Units. Procedures are described for collecting habitat data at basin and segment scales; these procedures include use of geographic information system data bases, topographic maps, and aerial photographs. Data collected at the reach scale include channel, bank, and riparian characteristics.

  1. Use of refractometry and colorimetry as field methods to rapidly assess antimalarial drug quality.

    PubMed

    Green, Michael D; Nettey, Henry; Villalva Rojas, Ofelia; Pamanivong, Chansapha; Khounsaknalath, Lamphet; Grande Ortiz, Miguel; Newton, Paul N; Fernández, Facundo M; Vongsack, Latsamy; Manolin, Ot

    2007-01-04

    The proliferation of counterfeit and poor-quality drugs is a major public health problem; especially in developing countries lacking adequate resources to effectively monitor their prevalence. Simple and affordable field methods provide a practical means of rapidly monitoring drug quality in circumstances where more advanced techniques are not available. Therefore, we have evaluated refractometry, colorimetry and a technique combining both processes as simple and accurate field assays to rapidly test the quality of the commonly available antimalarial drugs; artesunate, chloroquine, quinine, and sulfadoxine. Method bias, sensitivity, specificity and accuracy relative to high-performance liquid chromatographic (HPLC) analysis of drugs collected in the Lao PDR were assessed for each technique. The HPLC method for each drug was evaluated in terms of assay variability and accuracy. The accuracy of the combined method ranged from 0.96 to 1.00 for artesunate tablets, chloroquine injectables, quinine capsules, and sulfadoxine tablets while the accuracy was 0.78 for enterically coated chloroquine tablets. These techniques provide a generally accurate, yet simple and affordable means to assess drug quality in resource-poor settings.

  2. United3D: a protein model quality assessment program that uses two consensus based methods.

    PubMed

    Terashi, Genki; Oosawa, Makoto; Nakamura, Yuuki; Kanou, Kazuhiko; Takeda-Shitaka, Mayuko

    2012-01-01

    In protein structure prediction, such as template-based modeling and free modeling (ab initio modeling), the step that assesses the quality of protein models is very important. We have developed a model quality assessment (QA) program United3D that uses an optimized clustering method and a simple Cα atom contact-based potential. United3D automatically estimates the quality scores (Qscore) of predicted protein models that are highly correlated with the actual quality (GDT_TS). The performance of United3D was tested in the ninth Critical Assessment of protein Structure Prediction (CASP9) experiment. In CASP9, United3D showed the lowest average loss of GDT_TS (5.3) among the QA methods participated in CASP9. This result indicates that the performance of United3D to identify the high quality models from the models predicted by CASP9 servers on 116 targets was best among the QA methods that were tested in CASP9. United3D also produced high average Pearson correlation coefficients (0.93) and acceptable Kendall rank correlation coefficients (0.68) between the Qscore and GDT_TS. This performance was competitive with the other top ranked QA methods that were tested in CASP9. These results indicate that United3D is a useful tool for selecting high quality models from many candidate model structures provided by various modeling methods. United3D will improve the accuracy of protein structure prediction.

  3. Methods for Performing Survival Curve Quality-of-Life Assessments.

    PubMed

    Sumner, Walton; Ding, Eric; Fischer, Irene D; Hagen, Michael D

    2014-08-01

    Many medical decisions involve an implied choice between alternative survival curves, typically with differing quality of life. Common preference assessment methods neglect this structure, creating some risk of distortions. Survival curve quality-of-life assessments (SQLA) were developed from Gompertz survival curves fitting the general population's survival. An algorithm was developed to generate relative discount rate-utility (DRU) functions from a standard survival curve and health state and an equally attractive alternative curve and state. A least means squared distance algorithm was developed to describe how nearly 3 or more DRU functions intersect. These techniques were implemented in a program called X-Trade and tested. SQLA scenarios can portray realistic treatment choices. A side effect scenario portrays one prototypical choice, to extend life while experiencing some loss, such as an amputation. A risky treatment scenario portrays procedures with an initial mortality risk. A time trade scenario mimics conventional time tradeoffs. Each SQLA scenario yields DRU functions with distinctive shapes, such as sigmoid curves or vertical lines. One SQLA can imply a discount rate or utility if the other value is known and both values are temporally stable. Two SQLA exercises imply a unique discount rate and utility if the inferred DRU functions intersect. Three or more SQLA results can quantify uncertainty or inconsistency in discount rate and utility estimates. Pilot studies suggested that many subjects could learn to interpret survival curves and do SQLA. SQLA confuse some people. Compared with SQLA, standard gambles quantify very low utilities more easily, and time tradeoffs are simpler for high utilities. When discount rates approach zero, time tradeoffs are as informative and easier to do than SQLA. SQLA may complement conventional utility assessment methods. © The Author(s) 2014.

  4. Validation of a method for assessing resident physicians' quality improvement proposals.

    PubMed

    Leenstra, James L; Beckman, Thomas J; Reed, Darcy A; Mundell, William C; Thomas, Kris G; Krajicek, Bryan J; Cha, Stephen S; Kolars, Joseph C; McDonald, Furman S

    2007-09-01

    Residency programs involve trainees in quality improvement (QI) projects to evaluate competency in systems-based practice and practice-based learning and improvement. Valid approaches to assess QI proposals are lacking. We developed an instrument for assessing resident QI proposals--the Quality Improvement Proposal Assessment Tool (QIPAT-7)-and determined its validity and reliability. QIPAT-7 content was initially obtained from a national panel of QI experts. Through an iterative process, the instrument was refined, pilot-tested, and revised. Seven raters used the instrument to assess 45 resident QI proposals. Principal factor analysis was used to explore the dimensionality of instrument scores. Cronbach's alpha and intraclass correlations were calculated to determine internal consistency and interrater reliability, respectively. QIPAT-7 items comprised a single factor (eigenvalue = 3.4) suggesting a single assessment dimension. Interrater reliability for each item (range 0.79 to 0.93) and internal consistency reliability among the items (Cronbach's alpha = 0.87) were high. This method for assessing resident physician QI proposals is supported by content and internal structure validity evidence. QIPAT-7 is a useful tool for assessing resident QI proposals. Future research should determine the reliability of QIPAT-7 scores in other residency and fellowship training programs. Correlations should also be made between assessment scores and criteria for QI proposal success such as implementation of QI proposals, resident scholarly productivity, and improved patient outcomes.

  5. A solution quality assessment method for swarm intelligence optimization algorithms.

    PubMed

    Zhang, Zhaojun; Wang, Gai-Ge; Zou, Kuansheng; Zhang, Jianhua

    2014-01-01

    Nowadays, swarm intelligence optimization has become an important optimization tool and wildly used in many fields of application. In contrast to many successful applications, the theoretical foundation is rather weak. Therefore, there are still many problems to be solved. One problem is how to quantify the performance of algorithm in finite time, that is, how to evaluate the solution quality got by algorithm for practical problems. It greatly limits the application in practical problems. A solution quality assessment method for intelligent optimization is proposed in this paper. It is an experimental analysis method based on the analysis of search space and characteristic of algorithm itself. Instead of "value performance," the "ordinal performance" is used as evaluation criteria in this method. The feasible solutions were clustered according to distance to divide solution samples into several parts. Then, solution space and "good enough" set can be decomposed based on the clustering results. Last, using relative knowledge of statistics, the evaluation result can be got. To validate the proposed method, some intelligent algorithms such as ant colony optimization (ACO), particle swarm optimization (PSO), and artificial fish swarm algorithm (AFS) were taken to solve traveling salesman problem. Computational results indicate the feasibility of proposed method.

  6. Development of vibrational spectroscopic methods to rapidly and non-destructively assess quality of chicken breast meat

    USDA-ARS?s Scientific Manuscript database

    Development of Vibrational Spectroscopic Methods to Rapidly and Non-Destructively Assess Quality of Chicken Breast Meat H. Zhuang1, M. Sohn2, S. Trabelsi1 and K. Lawrence1 1Quality and Safety Assessment Research Unit, ARS-USDA, 950 College Station Road, Athens, GA 30605 2University of Georgia, De...

  7. TBDQ: A Pragmatic Task-Based Method to Data Quality Assessment and Improvement

    PubMed Central

    Vaziri, Reza; Mohsenzadeh, Mehran; Habibi, Jafar

    2016-01-01

    Organizations are increasingly accepting data quality (DQ) as a major key to their success. In order to assess and improve DQ, methods have been devised. Many of these methods attempt to raise DQ by directly manipulating low quality data. Such methods operate reactively and are suitable for organizations with highly developed integrated systems. However, there is a lack of a proactive DQ method for businesses with weak IT infrastructure where data quality is largely affected by tasks that are performed by human agents. This study aims to develop and evaluate a new method for structured data, which is simple and practical so that it can easily be applied to real world situations. The new method detects the potentially risky tasks within a process, and adds new improving tasks to counter them. To achieve continuous improvement, an award system is also developed to help with the better selection of the proposed improving tasks. The task-based DQ method (TBDQ) is most appropriate for small and medium organizations, and simplicity in implementation is one of its most prominent features. TBDQ is case studied in an international trade company. The case study shows that TBDQ is effective in selecting optimal activities for DQ improvement in terms of cost and improvement. PMID:27192547

  8. Concepts of Quality in Student Assessment.

    ERIC Educational Resources Information Center

    Harlen, Wynne

    This paper gives an overview of the methods of moderation, or quality assurance and quality control, as they may be more widely known, that are used to enhance the quality of student assessment. The discussion is based on the educational systems of the United Kingdom but is applicable to assessment in other countries. Quality in assessment is seen…

  9. Quality assessment of urban environment

    NASA Astrophysics Data System (ADS)

    Ovsiannikova, T. Y.; Nikolaenko, M. N.

    2015-01-01

    This paper is dedicated to the research applicability of quality management problems of construction products. It is offered to expand quality management borders in construction, transferring its principles to urban systems as economic systems of higher level, which qualitative characteristics are substantially defined by quality of construction product. Buildings and structures form spatial-material basis of cities and the most important component of life sphere - urban environment. Authors justify the need for the assessment of urban environment quality as an important factor of social welfare and life quality in urban areas. The authors suggest definition of a term "urban environment". The methodology of quality assessment of urban environment is based on integrated approach which includes the system analysis of all factors and application of both quantitative methods of assessment (calculation of particular and integrated indicators) and qualitative methods (expert estimates and surveys). The authors propose the system of indicators, characterizing quality of the urban environment. This indicators fall into four classes. The authors show the methodology of their definition. The paper presents results of quality assessment of urban environment for several Siberian regions and comparative analysis of these results.

  10. Methods for collecting algal samples as part of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Porter, Stephen D.; Cuffney, Thomas F.; Gurtz, Martin E.; Meador, Michael R.

    1993-01-01

    Benthic algae (periphyton) and phytoplankton communities are characterized in the U.S. Geological Survey's National Water-Quality Assessment Program as part of an integrated physical, chemical, and biological assessment of the Nation's water quality. This multidisciplinary approach provides multiple lines of evidence for evaluating water-quality status and trends, and for refining an understanding of the factors that affect water-quality conditions locally, regionally, and nationally. Water quality can be characterized by evaluating the results of qualitative and quantitative measurements of the algal community. Qualitative periphyton samples are collected to develop of list of taxa present in the sampling reach. Quantitative periphyton samples are collected to measure algal community structure within selected habitats. These samples of benthic algal communities are collected from natural substrates, using the sampling methods that are most appropriate for the habitat conditions. Phytoplankton samples may be collected in large nonwadeable streams and rivers to meet specific program objectives. Estimates of algal biomass (chlorophyll content and ash-free dry mass) also are optional measures that may be useful for interpreting water-quality conditions. A nationally consistent approach provides guidance on site, reach, and habitat selection, as well as information on methods and equipment for qualitative and quantitative sampling. Appropriate quality-assurance and quality-control guidelines are used to maximize the ability to analyze data locally, regionally, and nationally.

  11. Blind image quality assessment based on aesthetic and statistical quality-aware features

    NASA Astrophysics Data System (ADS)

    Jenadeleh, Mohsen; Masaeli, Mohammad Masood; Moghaddam, Mohsen Ebrahimi

    2017-07-01

    The main goal of image quality assessment (IQA) methods is the emulation of human perceptual image quality judgments. Therefore, the correlation between objective scores of these methods with human perceptual scores is considered as their performance metric. Human judgment of the image quality implicitly includes many factors when assessing perceptual image qualities such as aesthetics, semantics, context, and various types of visual distortions. The main idea of this paper is to use a host of features that are commonly employed in image aesthetics assessment in order to improve blind image quality assessment (BIQA) methods accuracy. We propose an approach that enriches the features of BIQA methods by integrating a host of aesthetics image features with the features of natural image statistics derived from multiple domains. The proposed features have been used for augmenting five different state-of-the-art BIQA methods, which use statistical natural scene statistics features. Experiments were performed on seven benchmark image quality databases. The experimental results showed significant improvement of the accuracy of the methods.

  12. A new four-step hierarchy method for combined assessment of groundwater quality and pollution.

    PubMed

    Zhu, Henghua; Ren, Xiaohua; Liu, Zhizheng

    2017-12-28

    A new four-step hierarchy method was constructed and applied to evaluate the groundwater quality and pollution of the Dagujia River Basin. The assessment index system is divided into four types: field test indices, common inorganic chemical indices, inorganic toxicology indices, and trace organic indices. Background values of common inorganic chemical indices and inorganic toxicology indices were estimated with the cumulative-probability curve method, and the results showed that the background values of Mg 2+ (51.1 mg L -1 ), total hardness (TH) (509.4 mg L -1 ), and NO 3 - (182.4 mg L -1 ) are all higher than the corresponding grade III values of Quality Standard for Groundwater, indicating that they were poor indicators and therefore were not included in the groundwater quality assessment. The quality assessment results displayed that the field test indices were mainly classified as grade II, accounting for 60.87% of wells sampled. The indices of common inorganic chemical and inorganic toxicology were both mostly in the range of grade III, whereas the trace organic indices were predominantly classified as grade I. The variabilities and excess ratios of the indices were also calculated and evaluated. Spatial distributions showed that the groundwater with poor quality indices was mainly located in the northeast of the basin, which was well-connected with seawater intrusion. Additionally, the pollution assessment revealed that groundwater in well 44 was classified as "moderately polluted," wells 5 and 8 were "lightly polluted," and other wells were classified as "unpolluted."

  13. Optimizing Scoring and Sampling Methods for Assessing Built Neighborhood Environment Quality in Residential Areas

    PubMed Central

    Adu-Brimpong, Joel; Coffey, Nathan; Ayers, Colby; Berrigan, David; Yingling, Leah R.; Thomas, Samantha; Mitchell, Valerie; Ahuja, Chaarushi; Rivers, Joshua; Hartz, Jacob; Powell-Wiley, Tiffany M.

    2017-01-01

    Optimization of existing measurement tools is necessary to explore links between aspects of the neighborhood built environment and health behaviors or outcomes. We evaluate a scoring method for virtual neighborhood audits utilizing the Active Neighborhood Checklist (the Checklist), a neighborhood audit measure, and assess street segment representativeness in low-income neighborhoods. Eighty-two home neighborhoods of Washington, D.C. Cardiovascular Health/Needs Assessment (NCT01927783) participants were audited using Google Street View imagery and the Checklist (five sections with 89 total questions). Twelve street segments per home address were assessed for (1) Land-Use Type; (2) Public Transportation Availability; (3) Street Characteristics; (4) Environment Quality and (5) Sidewalks/Walking/Biking features. Checklist items were scored 0–2 points/question. A combinations algorithm was developed to assess street segments’ representativeness. Spearman correlations were calculated between built environment quality scores and Walk Score®, a validated neighborhood walkability measure. Street segment quality scores ranged 10–47 (Mean = 29.4 ± 6.9) and overall neighborhood quality scores, 172–475 (Mean = 352.3 ± 63.6). Walk scores® ranged 0–91 (Mean = 46.7 ± 26.3). Street segment combinations’ correlation coefficients ranged 0.75–1.0. Significant positive correlations were found between overall neighborhood quality scores, four of the five Checklist subsection scores, and Walk Scores® (r = 0.62, p < 0.001). This scoring method adequately captures neighborhood features in low-income, residential areas and may aid in delineating impact of specific built environment features on health behaviors and outcomes. PMID:28282878

  14. Optimizing Scoring and Sampling Methods for Assessing Built Neighborhood Environment Quality in Residential Areas.

    PubMed

    Adu-Brimpong, Joel; Coffey, Nathan; Ayers, Colby; Berrigan, David; Yingling, Leah R; Thomas, Samantha; Mitchell, Valerie; Ahuja, Chaarushi; Rivers, Joshua; Hartz, Jacob; Powell-Wiley, Tiffany M

    2017-03-08

    Optimization of existing measurement tools is necessary to explore links between aspects of the neighborhood built environment and health behaviors or outcomes. We evaluate a scoring method for virtual neighborhood audits utilizing the Active Neighborhood Checklist (the Checklist), a neighborhood audit measure, and assess street segment representativeness in low-income neighborhoods. Eighty-two home neighborhoods of Washington, D.C. Cardiovascular Health/Needs Assessment (NCT01927783) participants were audited using Google Street View imagery and the Checklist (five sections with 89 total questions). Twelve street segments per home address were assessed for (1) Land-Use Type; (2) Public Transportation Availability; (3) Street Characteristics; (4) Environment Quality and (5) Sidewalks/Walking/Biking features. Checklist items were scored 0-2 points/question. A combinations algorithm was developed to assess street segments' representativeness. Spearman correlations were calculated between built environment quality scores and Walk Score ® , a validated neighborhood walkability measure. Street segment quality scores ranged 10-47 (Mean = 29.4 ± 6.9) and overall neighborhood quality scores, 172-475 (Mean = 352.3 ± 63.6). Walk scores ® ranged 0-91 (Mean = 46.7 ± 26.3). Street segment combinations' correlation coefficients ranged 0.75-1.0. Significant positive correlations were found between overall neighborhood quality scores, four of the five Checklist subsection scores, and Walk Scores ® ( r = 0.62, p < 0.001). This scoring method adequately captures neighborhood features in low-income, residential areas and may aid in delineating impact of specific built environment features on health behaviors and outcomes.

  15. Methods for assessing the quality of mammalian embryos: How far we are from the gold standard?

    PubMed

    Rocha, José C; Passalia, Felipe; Matos, Felipe D; Maserati, Marc P; Alves, Mayra F; Almeida, Tamie G de; Cardoso, Bruna L; Basso, Andrea C; Nogueira, Marcelo F G

    2016-08-01

    Morphological embryo classification is of great importance for many laboratory techniques, from basic research to the ones applied to assisted reproductive technology. However, the standard classification method for both human and cattle embryos, is based on quality parameters that reflect the overall morphological quality of the embryo in cattle, or the quality of the individual embryonic structures, more relevant in human embryo classification. This assessment method is biased by the subjectivity of the evaluator and even though several guidelines exist to standardize the classification, it is not a method capable of giving reliable and trustworthy results. Latest approaches for the improvement of quality assessment include the use of data from cellular metabolism, a new morphological grading system, development kinetics and cleavage symmetry, embryo cell biopsy followed by pre-implantation genetic diagnosis, zona pellucida birefringence, ion release by the embryo cells and so forth. Nowadays there exists a great need for evaluation methods that are practical and non-invasive while being accurate and objective. A method along these lines would be of great importance to embryo evaluation by embryologists, clinicians and other professionals who work with assisted reproductive technology. Several techniques shows promising results in this sense, one being the use of digital images of the embryo as basis for features extraction and classification by means of artificial intelligence techniques (as genetic algorithms and artificial neural networks). This process has the potential to become an accurate and objective standard for embryo quality assessment.

  16. Methods for assessing the quality of mammalian embryos: How far we are from the gold standard?

    PubMed Central

    Rocha, José C.; Passalia, Felipe; Matos, Felipe D.; Maserati Jr, Marc P.; Alves, Mayra F.; de Almeida, Tamie G.; Cardoso, Bruna L.; Basso, Andrea C.; Nogueira, Marcelo F. G.

    2016-01-01

    Morphological embryo classification is of great importance for many laboratory techniques, from basic research to the ones applied to assisted reproductive technology. However, the standard classification method for both human and cattle embryos, is based on quality parameters that reflect the overall morphological quality of the embryo in cattle, or the quality of the individual embryonic structures, more relevant in human embryo classification. This assessment method is biased by the subjectivity of the evaluator and even though several guidelines exist to standardize the classification, it is not a method capable of giving reliable and trustworthy results. Latest approaches for the improvement of quality assessment include the use of data from cellular metabolism, a new morphological grading system, development kinetics and cleavage symmetry, embryo cell biopsy followed by pre-implantation genetic diagnosis, zona pellucida birefringence, ion release by the embryo cells and so forth. Nowadays there exists a great need for evaluation methods that are practical and non-invasive while being accurate and objective. A method along these lines would be of great importance to embryo evaluation by embryologists, clinicians and other professionals who work with assisted reproductive technology. Several techniques shows promising results in this sense, one being the use of digital images of the embryo as basis for features extraction and classification by means of artificial intelligence techniques (as genetic algorithms and artificial neural networks). This process has the potential to become an accurate and objective standard for embryo quality assessment. PMID:27584609

  17. Use of Web Technology and Active Learning Strategies in a Quality Assessment Methods Course.

    ERIC Educational Resources Information Center

    Poirier, Therese I.; O'Neil, Christine K.

    2000-01-01

    The authors describe and evaluate quality assessment methods in a health care course that utilized web technology and various active learning strategies. The course was judged successful by student performance, evaluations and student assessments. The instructors were pleased with the outcomes achieved and the educational pedagogy used for this…

  18. Water Quality Assessment for Deep-water Channel area of Guangzhou Port based on the Comprehensive Water Quality Identification Index Method

    NASA Astrophysics Data System (ADS)

    Chen, Yi

    2018-03-01

    The comprehensive water quality identification index method is able to assess the general water quality situation comprehensively and represent the water quality classification; water environment functional zone achieves pollution level and standard objectively and systematically. This paper selects 3 representative zones along deep-water channel of Guangzhou port and applies comprehensive water quality identification index method to calculate sea water quality monitoring data for different selected zones from year 2006 to 2014, in order to investigate the temporal variation of water quality along deep-water channel of Guangzhou port. The comprehensive water quality level from north to south presents an increased trend, and the water quality of the three zones in 2014 is much better than in 2006. This paper puts forward environmental protection measurements and suggestions for Pearl River Estuary, provides data support and theoretical basis for studied sea area pollution prevention and control.

  19. A Quality Assessment Method Based on Common Distributed Targets for GF-3 Polarimetric SAR Data.

    PubMed

    Jiang, Sha; Qiu, Xiaolan; Han, Bing; Hu, Wenlong

    2018-03-07

    The GaoFen-3 (GF-3) satellite, launched on 10 August 2016, is the first C-band polarimetric synthetic aperture radar (PolSAR) satellite in China. The PolSAR system of GF-3 can collect a significant wealth of information for geophysical research and applications. Being used for related applications, GF-3 PolSAR images must be of good quality. It is necessary to evaluate the quality of polarimetric data and achieve the normalized quality monitoring during 8-year designed life of GF-3. In this study, a new quality assessment method of PolSAR data based on common distributed targets is proposed, and the performance of the method is analyzed by simulations and GF-3 experiments. We evaluate the quality of GF-3 PolSAR data by this method. Results suggest that GF-3 antenna is highly isolated, and the quality of calibrated data satisfies the requests of quantitative applications.

  20. Image quality assessment using deep convolutional networks

    NASA Astrophysics Data System (ADS)

    Li, Yezhou; Ye, Xiang; Li, Yong

    2017-12-01

    This paper proposes a method of accurately assessing image quality without a reference image by using a deep convolutional neural network. Existing training based methods usually utilize a compact set of linear filters for learning features of images captured by different sensors to assess their quality. These methods may not be able to learn the semantic features that are intimately related with the features used in human subject assessment. Observing this drawback, this work proposes training a deep convolutional neural network (CNN) with labelled images for image quality assessment. The ReLU in the CNN allows non-linear transformations for extracting high-level image features, providing a more reliable assessment of image quality than linear filters. To enable the neural network to take images of any arbitrary size as input, the spatial pyramid pooling (SPP) is introduced connecting the top convolutional layer and the fully-connected layer. In addition, the SPP makes the CNN robust to object deformations to a certain extent. The proposed method taking an image as input carries out an end-to-end learning process, and outputs the quality of the image. It is tested on public datasets. Experimental results show that it outperforms existing methods by a large margin and can accurately assess the image quality on images taken by different sensors of varying sizes.

  1. Assessing data quality and the variability of source data verification auditing methods in clinical research settings.

    PubMed

    Houston, Lauren; Probst, Yasmine; Martin, Allison

    2018-05-18

    Data audits within clinical settings are extensively used as a major strategy to identify errors, monitor study operations and ensure high-quality data. However, clinical trial guidelines are non-specific in regards to recommended frequency, timing and nature of data audits. The absence of a well-defined data quality definition and method to measure error undermines the reliability of data quality assessment. This review aimed to assess the variability of source data verification (SDV) auditing methods to monitor data quality in a clinical research setting. The scientific databases MEDLINE, Scopus and Science Direct were searched for English language publications, with no date limits applied. Studies were considered if they included data from a clinical trial or clinical research setting and measured and/or reported data quality using a SDV auditing method. In total 15 publications were included. The nature and extent of SDV audit methods in the articles varied widely, depending upon the complexity of the source document, type of study, variables measured (primary or secondary), data audit proportion (3-100%) and collection frequency (6-24 months). Methods for coding, classifying and calculating error were also inconsistent. Transcription errors and inexperienced personnel were the main source of reported error. Repeated SDV audits using the same dataset demonstrated ∼40% improvement in data accuracy and completeness over time. No description was given in regards to what determines poor data quality in clinical trials. A wide range of SDV auditing methods are reported in the published literature though no uniform SDV auditing method could be determined for "best practice" in clinical trials. Published audit methodology articles are warranted for the development of a standardised SDV auditing method to monitor data quality in clinical research settings. Copyright © 2018. Published by Elsevier Inc.

  2. No-Reference Image Quality Assessment by Wide-Perceptual-Domain Scorer Ensemble Method.

    PubMed

    Liu, Tsung-Jung; Liu, Kuan-Hsien

    2018-03-01

    A no-reference (NR) learning-based approach to assess image quality is presented in this paper. The devised features are extracted from wide perceptual domains, including brightness, contrast, color, distortion, and texture. These features are used to train a model (scorer) which can predict scores. The scorer selection algorithms are utilized to help simplify the proposed system. In the final stage, the ensemble method is used to combine the prediction results from selected scorers. Two multiple-scale versions of the proposed approach are also presented along with the single-scale one. They turn out to have better performances than the original single-scale method. Because of having features from five different domains at multiple image scales and using the outputs (scores) from selected score prediction models as features for multi-scale or cross-scale fusion (i.e., ensemble), the proposed NR image quality assessment models are robust with respect to more than 24 image distortion types. They also can be used on the evaluation of images with authentic distortions. The extensive experiments on three well-known and representative databases confirm the performance robustness of our proposed model.

  3. Research Notes - Openness and Evolvability - Documentation Quality Assessment

    DTIC Science & Technology

    2016-08-01

    UNCLASSIFIED UNCLASSIFIED Notes – Openness and Evolvability – Documentation Quality Assessment Michael Haddy* and Adam Sbrana...Methods and Processes. This set of Research Notes focusses on Documentation Quality Assessment. This work was undertaken from the late 1990s to 2007...1 2. DOCUMENTATION QUALITY ASSESSMENT ......................................................... 1 2.1 Documentation Quality Assessment

  4. A method based on IHS cylindrical transform model for quality assessment of image fusion

    NASA Astrophysics Data System (ADS)

    Zhu, Xiaokun; Jia, Yonghong

    2005-10-01

    Image fusion technique has been widely applied to remote sensing image analysis and processing, and methods for quality assessment of image fusion in remote sensing have also become the research issues at home and abroad. Traditional assessment methods combine calculation of quantitative indexes and visual interpretation to compare fused images quantificationally and qualitatively. However, in the existing assessment methods, there are two defects: on one hand, most imdexes lack the theoretic support to compare different fusion methods. On the hand, there is not a uniform preference for most of the quantitative assessment indexes when they are applied to estimate the fusion effects. That is, the spatial resolution and spectral feature could not be analyzed synchronously by these indexes and there is not a general method to unify the spatial and spectral feature assessment. So in this paper, on the basis of the approximate general model of four traditional fusion methods, including Intensity Hue Saturation(IHS) triangle transform fusion, High Pass Filter(HPF) fusion, Principal Component Analysis(PCA) fusion, Wavelet Transform(WT) fusion, a correlation coefficient assessment method based on IHS cylindrical transform is proposed. By experiments, this method can not only get the evaluation results of spatial and spectral features on the basis of uniform preference, but also can acquire the comparison between fusion image sources and fused images, and acquire differences among fusion methods. Compared with the traditional assessment methods, the new methods is more intuitionistic, and in accord with subjective estimation.

  5. [Method for the quality assessment of data collection processes in epidemiological studies].

    PubMed

    Schöne, G; Damerow, S; Hölling, H; Houben, R; Gabrys, L

    2017-10-01

    For a quantitative evaluation of primary data collection processes in epidemiological surveys based on accompaniments and observations (in the field), there is no description of test criteria and methodologies in relevant literature and thus no known application in practice. Therefore, methods need to be developed and existing procedures adapted. The aim was to identify quality-relevant developments within quality dimensions by means of inspection points (quality indicators) during the process of data collection. As a result we seek to implement and establish a methodology for the assessment of overall survey quality supplementary to standardized data analyses. Monitors detect deviations from standard primary data collection during site visits by applying standardized checklists. Quantitative results - overall and for each dimension - are obtained by numerical calculation of quality indicators. Score results are categorized and color coded. This visual prioritization indicates necessity for intervention. The results obtained give clues regarding the current quality of data collection. This allows for the identification of such sections where interventions for quality improvement are needed. In addition, process quality development can be shown over time on an intercomparable basis. This methodology for the evaluation of data collection quality can identify deviations from norms, focalize quality analyses and help trace causes for significant deviations.

  6. Synthesized view comparison method for no-reference 3D image quality assessment

    NASA Astrophysics Data System (ADS)

    Luo, Fangzhou; Lin, Chaoyi; Gu, Xiaodong; Ma, Xiaojun

    2018-04-01

    We develop a no-reference image quality assessment metric to evaluate the quality of synthesized view rendered from the Multi-view Video plus Depth (MVD) format. Our metric is named Synthesized View Comparison (SVC), which is designed for real-time quality monitoring at the receiver side in a 3D-TV system. The metric utilizes the virtual views in the middle which are warped from left and right views by Depth-image-based rendering algorithm (DIBR), and compares the difference between the virtual views rendered from different cameras by Structural SIMilarity (SSIM), a popular 2D full-reference image quality assessment metric. The experimental results indicate that our no-reference quality assessment metric for the synthesized images has competitive prediction performance compared with some classic full-reference image quality assessment metrics.

  7. [Quality assessment in anesthesia].

    PubMed

    Kupperwasser, B

    1996-01-01

    Quality assessment (assurance/improvement) is the set of methods used to measure and improve the delivered care and the department's performance against pre-established criteria or standards. The four stages of the self-maintained quality assessment cycle are: problem identification, problem analysis, problem correction and evaluation of corrective actions. Quality assessment is a measurable entity for which it is necessary to define and calibrate measurement parameters (indicators) from available data gathered from the hospital anaesthesia environment. Problem identification comes from the accumulation of indicators. There are four types of quality indicators: structure, process, outcome and sentinel indicators. The latter signal a quality defect, are independent of outcomes, are easier to analyse by statistical methods and closely related to processes and main targets of quality improvement. The three types of methods to analyse the problems (indicators) are: peer review, quantitative methods and risks management techniques. Peer review is performed by qualified anaesthesiologists. To improve its validity, the review process should be explicited and conclusions based on standards of practice and literature references. The quantitative methods are statistical analyses applied to the collected data and presented in a graphic format (histogram, Pareto diagram, control charts). The risks management techniques include: a) critical incident analysis establishing an objective relationship between a 'critical' event and the associated human behaviours; b) system accident analysis, based on the fact that accidents continue to occur despite safety systems and sophisticated technologies, checks of all the process components leading to the impredictable outcome and not just the human factors; c) cause-effect diagrams facilitate the problem analysis in reducing its causes to four fundamental components (persons, regulations, equipment, process). Definition and implementation

  8. Soil quality assessment using weighted fuzzy association rules

    USGS Publications Warehouse

    Xue, Yue-Ju; Liu, Shu-Guang; Hu, Yue-Ming; Yang, Jing-Feng

    2010-01-01

    Fuzzy association rules (FARs) can be powerful in assessing regional soil quality, a critical step prior to land planning and utilization; however, traditional FARs mined from soil quality database, ignoring the importance variability of the rules, can be redundant and far from optimal. In this study, we developed a method applying different weights to traditional FARs to improve accuracy of soil quality assessment. After the FARs for soil quality assessment were mined, redundant rules were eliminated according to whether the rules were significant or not in reducing the complexity of the soil quality assessment models and in improving the comprehensibility of FARs. The global weights, each representing the importance of a FAR in soil quality assessment, were then introduced and refined using a gradient descent optimization method. This method was applied to the assessment of soil resources conditions in Guangdong Province, China. The new approach had an accuracy of 87%, when 15 rules were mined, as compared with 76% from the traditional approach. The accuracy increased to 96% when 32 rules were mined, in contrast to 88% from the traditional approach. These results demonstrated an improved comprehensibility of FARs and a high accuracy of the proposed method.

  9. A new method of regional eco-environmental quality assessment and its application.

    PubMed

    Wang, Xiaodan; Cao, Yingzi; Zhong, Xianghao; Gao, Pan

    2012-01-01

    Eco-environmental quality assessment (EQA) is an intricate and challenging task that must take into account numerous natural, economic, political, and social factors, which are subject to multiple conflicting criteria. In this paper, a methodological reference framework is developed for EQA that combines the fuzzy Delphi method (FDM) and fuzzy analytical hierarchy process (FAHP) with a geographic information system (GIS). The proposed method significantly improves the accuracy and reliability of evaluation results through the incorporation of fuzzy set theory. A GIS not only has the ability to store and analyze large amounts of spatial data from different sources but also provides a consistent visualization environment for displaying the input data and the results of EQA. Furthermore, unlike prior EQAs, the proposed method can support the dynamic estimation of regional eco-environmental quality by updating historical spatiotemporal data at little additional cost. A case study is presented for the western Tibetan Plateau. The study results show that worse, bad, and moderate eco-environmental quality classes comprised 16.58, 20.15, and 24.84% of the total area, respectively. Good and better eco-environmental quality classes accounted for 38.43%. This result indicates that nearly 62% of the total area is eco-environmentally vulnerable. The results verified the usefulness and feasibility of the proposed method. The EQA can also help local managers make scientifically based and effective decisions about Tibetan eco-environmental protection and land use. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  10. Development of a quality instrument for assessing the spontaneous reports of ADR/ADE using Delphi method in China.

    PubMed

    Chen, Lixun; Jiang, Ling; Shen, Aizong; Wei, Wei

    2016-09-01

    The frequently low quality of submitted spontaneous reports is of an increasing concern; to our knowledge, no validated instrument exists for assessing case reports' quality comprehensively enough. This work was conducted to develop such a quality instrument for assessing the spontaneous reports of adverse drug reaction (ADR)/adverse drug event (ADE) in China. Initial evaluation indicators were generated using systematic and literature data analysis. Final indicators and their weights were identified using Delphi method. The final quality instrument was developed by adopting the synthetic scoring method. A consensus was reached after four rounds of Delphi survey. The developed quality instrument consisted of 6 first-rank indicators, 18 second-rank indicators, and 115 third-rank indicators, and each rank indicator has been weighted. It evaluates the quality of spontaneous reports of ADR/ADE comprehensively and quantitatively on six parameters: authenticity, duplication, regulatory, completeness, vigilance level, and reporting time frame. The developed instrument was tested with good reliability and validity, which can be used to comprehensively and quantitatively assess the submitted spontaneous reports of ADR/ADE in China.

  11. Methods for collecting benthic invertebrate samples as part of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Cuffney, Thomas F.; Gurtz, Martin E.; Meador, Michael R.

    1993-01-01

    Benthic invertebrate communities are evaluated as part of the ecological survey component of the U.S. Geological Survey's National Water-Quality Assessment Program. These biological data are collected along with physical and chemical data to assess water-quality conditions and to develop an understanding of the factors that affect water-quality conditions locally, regionally, and nationally. The objectives of benthic invertebrate community characterizations are to (1) develop for each site a list of tax a within the associated stream reach and (2) determine the structure of benthic invertebrate communities within selected habitats of that reach. A nationally consistent approach is used to achieve these objectives. This approach provides guidance on site, reach, and habitat selection and methods and equipment for qualitative multihabitat sampling and semi-quantitative single habitat sampling. Appropriate quality-assurance and quality-control guidelines are used to maximize the ability to analyze data within and among study units.

  12. An examination of the hexokinase method for serum glucose assay using external quality assessment data.

    PubMed

    Westwood, A; Bullock, D G; Whitehead, T P

    1986-01-01

    Hexokinase methods for serum glucose assay appeared to give slightly but consistently higher inter-laboratory coefficients of variation than all methods combined in the UK External Quality Assessment Scheme; their performance over a two-year period was therefore compared with that for three groups of glucose oxidase methods. This assessment showed no intrinsic inferiority in the hexokinase method. The greater variation may be due to the more heterogeneous group of instruments, particularly discrete analysers, on which the method is used. The Beckman Glucose Analyzer and Astra group (using a glucose oxidase method) showed the least inter-laboratory variability but also the lowest mean value. No comment is offered on the absolute accuracy of any of the methods.

  13. Design and methods of the Pacific Northwest Stream Quality Assessment (PNSQA), 2015

    USGS Publications Warehouse

    Sheibley, Rich W.; Morace, Jennifer L.; Journey, Celeste A.; Van Metre, Peter C.; Bell, Amanda H.; Nakagaki, Naomi; Button, Daniel T.; Qi, Sharon L.

    2017-08-25

    In 2015, the U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) project conducted the Pacific Northwest Stream Quality Assessment (PNSQA) to investigate stream quality across the western part of the Pacific Northwest. The goal of the PNSQA was to assess the health of streams in the region by characterizing multiple water-quality factors that are stressors to in-stream aquatic life and by evaluating the relation between these stressors and the condition of biological communities. The effects of urbanization and agriculture on stream quality for the Puget Lowland and Willamette Valley Level III Ecoregions were the focus of this regional study. Findings will help inform the public and policymakers about human and environmental factors that are the most critical in affecting stream quality and, thus, provide insights into possible strategies to protect or improve the health of streams in the region.Land-use data were used in the study to identify and select sites within the region that ranged in levels of urban and agricultural development. A total of 88 sites were selected across the region—69 were on streams that explicitly spanned a range of urban land use in their watersheds, 8 were on streams in agricultural watersheds, and 11 were reference sites with little or no development in their watersheds. Depending on the type of land use, sites were sampled for contaminants, nutrients, and sediment for either a 4- or 10-week period during April, May, and June 2015. This water-quality “index period” was immediately followed with an ecological survey of all sites that included stream habitat, benthic algae, benthic macroinvertebrates, and fish. Additionally, streambed sediment was collected during the ecological survey for analysis of sediment chemistry and toxicity testing.This report provides a detailed description of the specific study components and methods of the PNSQA, including (1) surveys of stream habitat and aquatic biota, (2) discrete

  14. Noise Estimation and Quality Assessment of Gaussian Noise Corrupted Images

    NASA Astrophysics Data System (ADS)

    Kamble, V. M.; Bhurchandi, K.

    2018-03-01

    Evaluating the exact quantity of noise present in an image and quality of an image in the absence of reference image is a challenging task. We propose a near perfect noise estimation method and a no reference image quality assessment method for images corrupted by Gaussian noise. The proposed methods obtain initial estimate of noise standard deviation present in an image using the median of wavelet transform coefficients and then obtains a near to exact estimate using curve fitting. The proposed noise estimation method provides the estimate of noise within average error of +/-4%. For quality assessment, this noise estimate is mapped to fit the Differential Mean Opinion Score (DMOS) using a nonlinear function. The proposed methods require minimum training and yields the noise estimate and image quality score. Images from Laboratory for image and Video Processing (LIVE) database and Computational Perception and Image Quality (CSIQ) database are used for validation of the proposed quality assessment method. Experimental results show that the performance of proposed quality assessment method is at par with the existing no reference image quality assessment metric for Gaussian noise corrupted images.

  15. Methods to characterize environmental settings of stream and groundwater sampling sites for National Water-Quality Assessment

    USGS Publications Warehouse

    Nakagaki, Naomi; Hitt, Kerie J.; Price, Curtis V.; Falcone, James A.

    2012-01-01

    Characterization of natural and anthropogenic features that define the environmental settings of sampling sites for streams and groundwater, including drainage basins and groundwater study areas, is an essential component of water-quality and ecological investigations being conducted as part of the U.S. Geological Survey's National Water-Quality Assessment program. Quantitative characterization of environmental settings, combined with physical, chemical, and biological data collected at sampling sites, contributes to understanding the status of, and influences on, water-quality and ecological conditions. To support studies for the National Water-Quality Assessment program, a geographic information system (GIS) was used to develop a standard set of methods to consistently characterize the sites, drainage basins, and groundwater study areas across the nation. This report describes three methods used for characterization-simple overlay, area-weighted areal interpolation, and land-cover-weighted areal interpolation-and their appropriate applications to geographic analyses that have different objectives and data constraints. In addition, this document records the GIS thematic datasets that are used for the Program's national design and data analyses.

  16. Identification of suitable fundus images using automated quality assessment methods.

    PubMed

    Şevik, Uğur; Köse, Cemal; Berber, Tolga; Erdöl, Hidayet

    2014-04-01

    Retinal image quality assessment (IQA) is a crucial process for automated retinal image analysis systems to obtain an accurate and successful diagnosis of retinal diseases. Consequently, the first step in a good retinal image analysis system is measuring the quality of the input image. We present an approach for finding medically suitable retinal images for retinal diagnosis. We used a three-class grading system that consists of good, bad, and outlier classes. We created a retinal image quality dataset with a total of 216 consecutive images called the Diabetic Retinopathy Image Database. We identified the suitable images within the good images for automatic retinal image analysis systems using a novel method. Subsequently, we evaluated our retinal image suitability approach using the Digital Retinal Images for Vessel Extraction and Standard Diabetic Retinopathy Database Calibration level 1 public datasets. The results were measured through the F1 metric, which is a harmonic mean of precision and recall metrics. The highest F1 scores of the IQA tests were 99.60%, 96.50%, and 85.00% for good, bad, and outlier classes, respectively. Additionally, the accuracy of our suitable image detection approach was 98.08%. Our approach can be integrated into any automatic retinal analysis system with sufficient performance scores.

  17. Quality Assessment in the Blog Space

    ERIC Educational Resources Information Center

    Schaal, Markus; Fidan, Guven; Muller, Roland M.; Dagli, Orhan

    2010-01-01

    Purpose: The purpose of this paper is the presentation of a new method for blog quality assessment. The method uses the temporal sequence of link creation events between blogs as an implicit source for the collective tacit knowledge of blog authors about blog quality. Design/methodology/approach: The blog data are processed by the novel method for…

  18. Validation of a combi oven cooking method for preparation of chicken breast meat for quality assessment.

    PubMed

    Zhuang, H; Savage, E M

    2008-10-01

    Quality assessment results of cooked meat can be significantly affected by sample preparation with different cooking techniques. A combi oven is a relatively new cooking technique in the U.S. market. However, there was a lack of published data about its effect on quality measurements of chicken meat. Broiler breast fillets deboned at 24-h postmortem were cooked with one of the 3 methods to the core temperature of 80 degrees C. Cooking methods were evaluated based on cooking operation requirements, sensory profiles, Warner-Bratzler (WB) shear and cooking loss. Our results show that the average cooking time for the combi oven was 17 min compared with 31 min for the commercial oven method and 16 min for the hot water method. The combi oven did not result in a significant difference in the WB shear force values, although the cooking loss of the combi oven samples was significantly lower than the commercial oven and hot water samples. Sensory profiles of the combi oven samples did not significantly differ from those of the commercial oven and hot water samples. These results demonstrate that combi oven cooking did not significantly affect sensory profiles and WB shear force measurements of chicken breast muscle compared to the other 2 cooking methods. The combi oven method appears to be an acceptable alternative for preparing chicken breast fillets in a quality assessment.

  19. Assessment methods for rehabilitation.

    PubMed

    Biefang, S; Potthoff, P

    1995-09-01

    Diagnostics and evaluation in medical rehabilitation should be based on methods that are as objective as possible. In this context quantitative methods are an important precondition. We conducted for the German Pensions Insurance Institutions (which are in charge of the medical and vocational rehabilitation of workers and employees) a survey on assessment methods for rehabilitation which included an evaluation of American literature, with the aim to indicate procedures that can be considered for adaptation in Germany and to define further research requirements. The survey identified: (1) standardized procedures and instrumented tests for the assessment of musculoskeletal, cardiopulmonary and neurophysiological function; (2) personality, intelligence, achievement, neuropsychological and alcoholism screening tests for the assessment of mental or cognitive function; (3) rating scales and self-administered questionnaires for the assessment of Activities of Daily Living and Instrumental Activities of Daily Living (ADL/IADL Scales); (4) generic profiles and indexes as well as disease-specific measures for the assessment of health-related quality of life and health status; and (5) rating scales for vocational assessment. German equivalents or German versions exist only for a part of the procedures identified. Translation and testing of Anglo-Saxon procedures should have priority over the development of new German methods. The following procedures will be taken into account: (a) instrumented tests for physical function, (b) IADL Scales, (c) generic indexes of health-related quality of life, (d) specific quality of life and health status measures for disorders of the circulatory system, metabolic system, digestive organs, respiratory tract and for cancer, and (e) vocational rating scales.

  20. Assessing groundwater quality for irrigation using indicator kriging method

    NASA Astrophysics Data System (ADS)

    Delbari, Masoomeh; Amiri, Meysam; Motlagh, Masoud Bahraini

    2016-11-01

    One of the key parameters influencing sprinkler irrigation performance is water quality. In this study, the spatial variability of groundwater quality parameters (EC, SAR, Na+, Cl-, HCO3 - and pH) was investigated by geostatistical methods and the most suitable areas for implementation of sprinkler irrigation systems in terms of water quality are determined. The study was performed in Fasa county of Fars province using 91 water samples. Results indicated that all parameters are moderately to strongly spatially correlated over the study area. The spatial distribution of pH and HCO3 - was mapped using ordinary kriging. The probability of concentrations of EC, SAR, Na+ and Cl- exceeding a threshold limit in groundwater was obtained using indicator kriging (IK). The experimental indicator semivariograms were often fitted well by a spherical model for SAR, EC, Na+ and Cl-. For HCO3 - and pH, an exponential model was fitted to the experimental semivariograms. Probability maps showed that the risk of EC, SAR, Na+ and Cl- exceeding the given critical threshold is higher in lower half of the study area. The most proper agricultural lands for sprinkler irrigation implementation were identified by evaluating all probability maps. The suitable areas for sprinkler irrigation design were determined to be 25,240 hectares, which is about 34 percent of total agricultural lands and are located in northern and eastern parts. Overall the results of this study showed that IK is an appropriate approach for risk assessment of groundwater pollution, which is useful for a proper groundwater resources management.

  1. Automated image quality assessment for chest CT scans.

    PubMed

    Reeves, Anthony P; Xie, Yiting; Liu, Shuang

    2018-02-01

    Medical image quality needs to be maintained at standards sufficient for effective clinical reading. Automated computer analytic methods may be applied to medical images for quality assessment. For chest CT scans in a lung cancer screening context, an automated quality assessment method is presented that characterizes image noise and image intensity calibration. This is achieved by image measurements in three automatically segmented homogeneous regions of the scan: external air, trachea lumen air, and descending aorta blood. Profiles of CT scanner behavior are also computed. The method has been evaluated on both phantom and real low-dose chest CT scans and results show that repeatable noise and calibration measures may be realized by automated computer algorithms. Noise and calibration profiles show relevant differences between different scanners and protocols. Automated image quality assessment may be useful for quality control for lung cancer screening and may enable performance improvements to automated computer analysis methods. © 2017 American Association of Physicists in Medicine.

  2. Learning Receptive Fields and Quality Lookups for Blind Quality Assessment of Stereoscopic Images.

    PubMed

    Shao, Feng; Lin, Weisi; Wang, Shanshan; Jiang, Gangyi; Yu, Mei; Dai, Qionghai

    2016-03-01

    Blind quality assessment of 3D images encounters more new challenges than its 2D counterparts. In this paper, we propose a blind quality assessment for stereoscopic images by learning the characteristics of receptive fields (RFs) from perspective of dictionary learning, and constructing quality lookups to replace human opinion scores without performance loss. The important feature of the proposed method is that we do not need a large set of samples of distorted stereoscopic images and the corresponding human opinion scores to learn a regression model. To be more specific, in the training phase, we learn local RFs (LRFs) and global RFs (GRFs) from the reference and distorted stereoscopic images, respectively, and construct their corresponding local quality lookups (LQLs) and global quality lookups (GQLs). In the testing phase, blind quality pooling can be easily achieved by searching optimal GRF and LRF indexes from the learnt LQLs and GQLs, and the quality score is obtained by combining the LRF and GRF indexes together. Experimental results on three publicly 3D image quality assessment databases demonstrate that in comparison with the existing methods, the devised algorithm achieves high consistent alignment with subjective assessment.

  3. A review of image quality assessment methods with application to computational photography

    NASA Astrophysics Data System (ADS)

    Maître, Henri

    2015-12-01

    Image quality assessment has been of major importance for several domains of the industry of image as for instance restoration or communication and coding. New application fields are opening today with the increase of embedded power in the camera and the emergence of computational photography: automatic tuning, image selection, image fusion, image data-base building, etc. We review the literature of image quality evaluation. We pay attention to the very different underlying hypotheses and results of the existing methods to approach the problem. We explain why they differ and for which applications they may be beneficial. We also underline their limits, especially for a possible use in the novel domain of computational photography. Being developed to address different objectives, they propose answers on different aspects, which make them sometimes complementary. However, they all remain limited in their capability to challenge the human expert, the said or unsaid ultimate goal. We consider the methods which are based on retrieving the parameters of a signal, mostly in spectral analysis; then we explore the more global methods to qualify the image quality in terms of noticeable defects or degradation as popular in the compression domain; in a third field the image acquisition process is considered as a channel between the source and the receiver, allowing to use the tools of the information theory and to qualify the system in terms of entropy and information capacity. However, these different approaches hardly attack the most difficult part of the task which is to measure the quality of the photography in terms of aesthetic properties. To help in addressing this problem, in between Philosophy, Biology and Psychology, we propose a brief review of the literature which addresses the problematic of qualifying Beauty, present the attempts to adapt these concepts to visual patterns and initiate a reflection on what could be done in the field of photography.

  4. Water quality assessment with hierarchical cluster analysis based on Mahalanobis distance.

    PubMed

    Du, Xiangjun; Shao, Fengjing; Wu, Shunyao; Zhang, Hanlin; Xu, Si

    2017-07-01

    Water quality assessment is crucial for assessment of marine eutrophication, prediction of harmful algal blooms, and environment protection. Previous studies have developed many numeric modeling methods and data driven approaches for water quality assessment. The cluster analysis, an approach widely used for grouping data, has also been employed. However, there are complex correlations between water quality variables, which play important roles in water quality assessment but have always been overlooked. In this paper, we analyze correlations between water quality variables and propose an alternative method for water quality assessment with hierarchical cluster analysis based on Mahalanobis distance. Further, we cluster water quality data collected form coastal water of Bohai Sea and North Yellow Sea of China, and apply clustering results to evaluate its water quality. To evaluate the validity, we also cluster the water quality data with cluster analysis based on Euclidean distance, which are widely adopted by previous studies. The results show that our method is more suitable for water quality assessment with many correlated water quality variables. To our knowledge, it is the first attempt to apply Mahalanobis distance for coastal water quality assessment.

  5. WATER CHEMISTRY ASSESSMENT METHODS

    EPA Science Inventory

    This section summarizes and evaluates the surfce water column chemistry assessment methods for USEPA/EMAP-SW, USGS-NAQA, USEPA-RBP, Oho EPA, and MDNR-MBSS. The basic objective of surface water column chemistry assessment is to characterize surface water quality by measuring a sui...

  6. A suite of phantom-based test methods for assessing image quality of photoacoustic tomography systems

    NASA Astrophysics Data System (ADS)

    Vogt, William C.; Jia, Congxian; Wear, Keith A.; Garra, Brian S.; Pfefer, T. Joshua

    2017-03-01

    As Photoacoustic Tomography (PAT) matures and undergoes clinical translation, objective performance test methods are needed to facilitate device development, regulatory clearance and clinical quality assurance. For mature medical imaging modalities such as CT, MRI, and ultrasound, tissue-mimicking phantoms are frequently incorporated into consensus standards for performance testing. A well-validated set of phantom-based test methods is needed for evaluating performance characteristics of PAT systems. To this end, we have constructed phantoms using a custom tissue-mimicking material based on PVC plastisol with tunable, biologically-relevant optical and acoustic properties. Each phantom is designed to enable quantitative assessment of one or more image quality characteristics including 3D spatial resolution, spatial measurement accuracy, ultrasound/PAT co-registration, uniformity, penetration depth, geometric distortion, sensitivity, and linearity. Phantoms contained targets including high-intensity point source targets and dye-filled tubes. This suite of phantoms was used to measure the dependence of performance of a custom PAT system (equipped with four interchangeable linear array transducers of varying design) on design parameters (e.g., center frequency, bandwidth, element geometry). Phantoms also allowed comparison of image artifacts, including surface-generated clutter and bandlimited sensing artifacts. Results showed that transducer design parameters create strong variations in performance including a trade-off between resolution and penetration depth, which could be quantified with our method. This study demonstrates the utility of phantom-based image quality testing in device performance assessment, which may guide development of consensus standards for PAT systems.

  7. MQAPRank: improved global protein model quality assessment by learning-to-rank.

    PubMed

    Jing, Xiaoyang; Dong, Qiwen

    2017-05-25

    Protein structure prediction has achieved a lot of progress during the last few decades and a greater number of models for a certain sequence can be predicted. Consequently, assessing the qualities of predicted protein models in perspective is one of the key components of successful protein structure prediction. Over the past years, a number of methods have been developed to address this issue, which could be roughly divided into three categories: single methods, quasi-single methods and clustering (or consensus) methods. Although these methods achieve much success at different levels, accurate protein model quality assessment is still an open problem. Here, we present the MQAPRank, a global protein model quality assessment program based on learning-to-rank. The MQAPRank first sorts the decoy models by using single method based on learning-to-rank algorithm to indicate their relative qualities for the target protein. And then it takes the first five models as references to predict the qualities of other models by using average GDT_TS scores between reference models and other models. Benchmarked on CASP11 and 3DRobot datasets, the MQAPRank achieved better performances than other leading protein model quality assessment methods. Recently, the MQAPRank participated in the CASP12 under the group name FDUBio and achieved the state-of-the-art performances. The MQAPRank provides a convenient and powerful tool for protein model quality assessment with the state-of-the-art performances, it is useful for protein structure prediction and model quality assessment usages.

  8. A comprehensive framework for data quality assessment in CER.

    PubMed

    Holve, Erin; Kahn, Michael; Nahm, Meredith; Ryan, Patrick; Weiskopf, Nicole

    2013-01-01

    The panel addresses the urgent need to ensure that comparative effectiveness research (CER) findings derived from diverse and distributed data sources are based on credible, high-quality data; and that the methods used to assess and report data quality are consistent, comprehensive, and available to data consumers. The panel consists of representatives from four teams leveraging electronic clinical data for CER, patient centered outcomes research (PCOR), and quality improvement (QI) and seeks to change the current paradigm where data quality assessment (DQA) is performed "behind the scenes" using one-off project specific methods. The panelists will present their process of harmonizing existing models for describing and measuring clinical data quality and will describe a comprehensive integrated framework for assessing and reporting DQA findings. The collaborative project is supported by the Electronic Data Methods (EDM) Forum, a three-year grant from the Agency for Healthcare Research and Quality (AHRQ) to facilitate learning and foster collaboration across a set of CER, PCOR, and QI projects designed to build infrastructure and methods for collecting and analyzing prospective data from electronic clinical data .

  9. Quality Assessment of Internationalised Studies: Theory and Practice

    ERIC Educational Resources Information Center

    Juknyte-Petreikiene, Inga

    2013-01-01

    The article reviews forms of higher education internationalisation at an institutional level. The relevance of theoretical background of internationalised study quality assessment is highlighted and definitions of internationalised studies quality are presented. Existing methods of assessment of higher education internationalisation are criticised…

  10. Remote Sensing Image Quality Assessment Experiment with Post-Processing

    NASA Astrophysics Data System (ADS)

    Jiang, W.; Chen, S.; Wang, X.; Huang, Q.; Shi, H.; Man, Y.

    2018-04-01

    This paper briefly describes the post-processing influence assessment experiment, the experiment includes three steps: the physical simulation, image processing, and image quality assessment. The physical simulation models sampled imaging system in laboratory, the imaging system parameters are tested, the digital image serving as image processing input are produced by this imaging system with the same imaging system parameters. The gathered optical sampled images with the tested imaging parameters are processed by 3 digital image processes, including calibration pre-processing, lossy compression with different compression ratio and image post-processing with different core. Image quality assessment method used is just noticeable difference (JND) subject assessment based on ISO20462, through subject assessment of the gathered and processing images, the influence of different imaging parameters and post-processing to image quality can be found. The six JND subject assessment experimental data can be validated each other. Main conclusions include: image post-processing can improve image quality; image post-processing can improve image quality even with lossy compression, image quality with higher compression ratio improves less than lower ratio; with our image post-processing method, image quality is better, when camera MTF being within a small range.

  11. Total Quality Management of Information System for Quality Assessment of Pesantren Using Fuzzy-SERVQUAL

    NASA Astrophysics Data System (ADS)

    Faizah, Arbiati; Syafei, Wahyul Amien; Isnanto, R. Rizal

    2018-02-01

    This research proposed a model combining an approach of Total Quality Management (TQM) and Fuzzy method of Service Quality (SERVQUAL) to asses service quality. TQM implementation was as quality management orienting on customer's satisfaction by involving all stakeholders. SERVQUAL model was used to measure quality service based on five dimensions such as tangible, reliability, responsiveness, assurance, and empathy. Fuzzy set theory was to accommodate subjectivity and ambiguity of quality assessment. Input data consisted of indicator data and quality assessment aspect. Input data was, then, processed to be service quality assessment questionnaires of Pesantren by using Fuzzy method to get service quality score. This process consisted of some steps as follows : inputting dimension and questionnaire data to data base system, filling questionnaire through system, then, system calculated fuzzification, defuzzification, gap of quality expected and received by service receivers, and calculating each dimension rating showing quality refinement priority. Rating of each quality dimension was, then, displayed at dashboard system to enable users to see information. From system having been built, it could be known that tangible dimension had the highest gap, -0.399, thus it needs to be prioritized and gets evaluation and refinement action soon.

  12. Evaluating the implementation of confusion assessment method-intensive care unit using a quality improvement approach.

    PubMed

    Stewart, C; Bench, S

    2018-05-15

    Quality improvement (QI) is a way through which health care delivery can be made safer and more effective. Various models of quality improvement methods exist in health care today. These models can help guide and manage the process of introducing changes into clinical practice. The aim of this project was to implement the use of a delirium assessment tool into three adult critical care units within the same hospital using a QI approach. The objective was to improve the identification and management of delirium. Using the Model for Improvement framework, a multidisciplinary working group was established. A delirium assessment tool was introduced via a series of educational initiatives. New local guidelines regarding the use of delirium assessment and management for the multidisciplinary team were also produced. Audit data were collected at 6 weeks and 5 months post-implementation to evaluate compliance with the use of the tool across three critical care units within a single hospital in London. At 6 weeks, in 134 assessment points out of a possible 202, the tool was deemed to be used appropriately, meaning that 60% of patients received timely assessment; 18% of patients were identified as delirious in audit one. Five months later, only 95 assessment points out of a possible 199 were being appropriately assessed (47%); however, a greater number (32%) were identified as delirious. This project emphasizes the complexity of changing practice in a large busy critical care centre. Despite an initial increase in delirium assessment, this was not sustained over time. The use of a QI model highlights the continuous process of embedding changes into clinical practice and the need to use a QI method that can address the challenging nature of modern health care. QI models guide changes in practice. Consideration should be given to the type of QI model used. © 2018 British Association of Critical Care Nurses.

  13. Automatic quality assessment of planetary images

    NASA Astrophysics Data System (ADS)

    Sidiropoulos, P.; Muller, J.-P.

    2015-10-01

    A significant fraction of planetary images are corrupted beyond the point that much scientific meaning can be extracted. For example, transmission errors result in missing data which is unrecoverable. The available planetary image datasets include many such "bad data", which both occupy valuable scientific storage resources and create false impressions about planetary image availability for specific planetary objects or target areas. In this work, we demonstrate a pipeline that we have developed to automatically assess the quality of planetary images. Additionally, this method discriminates between different types of image degradation, such as low-quality originating from camera flaws or low-quality triggered by atmospheric conditions, etc. Examples of quality assessment results for Viking Orbiter imagery will be also presented.

  14. [Analgesic quality in a postoperative pain service: continuous assessment with the cumulative sum (cusum) method].

    PubMed

    Baptista Macaroff, W M; Castroman Espasandín, P

    2007-01-01

    The aim of this study was to assess the cumulative sum (cusum) method for evaluating the performance of our hospital's acute postoperative pain service. The period of analysis was 7 months. Analgesic failure was defined as a score of 3 points or more on a simple numerical scale. Acceptable failure (p0) was set at 20% of patients upon admission to the postanesthetic recovery unit and at 7% 24 hours after surgery. Unacceptable failure was set at double the p0 rate at each time (40% and 14%, respectively). The unit's patient records were used to generate a cusum graph for each evaluation. Nine hundred four records were included. The rate of failure was 31.6% upon admission to the unit and 12.1% at the 24-hour postoperative assessment. The curve rose rapidly to the value set for p0 at both evaluation times (n = 14 and n = 17, respectively), later leveled off, and began to fall after 721 and 521 cases, respectively. Our study shows the efficacy of the cusum method for monitoring a proposed quality standard. The graph also showed periods of suboptimal performance that would not have been evident from analyzing the data en block. Thus the cusum method would facilitate rapid detection of periods in which quality declines.

  15. An assessment model for quality management

    NASA Astrophysics Data System (ADS)

    Völcker, Chr.; Cass, A.; Dorling, A.; Zilioli, P.; Secchi, P.

    2002-07-01

    SYNSPACE together with InterSPICE and Alenia Spazio is developing an assessment method to determine the capability of an organisation in the area of quality management. The method, sponsored by the European Space Agency (ESA), is called S9kS (SPiCE- 9000 for SPACE). S9kS is based on ISO 9001:2000 with additions from the quality standards issued by the European Committee for Space Standardization (ECSS) and ISO 15504 - Process Assessments. The result is a reference model that supports the expansion of the generic process assessment framework provided by ISO 15504 to nonsoftware areas. In order to be compliant with ISO 15504, requirements from ISO 9001 and ECSS-Q-20 and Q-20-09 have been turned into process definitions in terms of Purpose and Outcomes, supported by a list of detailed indicators such as Practices, Work Products and Work Product Characteristics. In coordination with this project, the capability dimension of ISO 15504 has been revised to be consistent with ISO 9001. As contributions from ISO 9001 and the space quality assurance standards are separable, the stripped down version S9k offers organisations in all industries an assessment model based solely on ISO 9001, and is therefore interesting to all organisations, which intend to improve their quality management system based on ISO 9001.

  16. Design and methods of the Midwest Stream Quality Assessment (MSQA), 2013

    USGS Publications Warehouse

    Garrett, Jessica D.; Frey, Jeffrey W.; Van Metre, Peter C.; Journey, Celeste A.; Nakagaki, Naomi; Button, Daniel T.; Nowell, Lisa H.

    2017-10-18

    During 2013, the U.S. Geological Survey (USGS) National Water-Quality Assessment Project (NAWQA), in collaboration with the USGS Columbia Environmental Research Center, the U.S. Environmental Protection Agency (EPA) National Rivers and Streams Assessment (NRSA), and the EPA Office of Pesticide Programs assessed stream quality across the Midwestern United States. This Midwest Stream Quality Assessment (MSQA) simultaneously characterized watershed and stream-reach water-quality stressors along with instream biological conditions, to better understand regional stressor-effects relations. The MSQA design focused on effects from the widespread agriculture in the region and urban development because of their importance as ecological stressors of particular concern to Midwest region resource managers.A combined random stratified selection and a targeted selection based on land-use data were used to identify and select sites representing gradients in agricultural intensity across the region. During a 14-week period from May through August 2013, 100 sites were selected and sampled 12 times for contaminants, nutrients, and sediment. This 14-week water-quality “index” period culminated with an ecological survey of habitat, periphyton, benthic macroinvertebrates, and fish at all sites. Sediment was collected during the ecological survey for analysis of sediment chemistry and toxicity testing. Of the 100 sites, 50 were selected for the MSQA random stratified group from 154 NRSA sites planned for the region, and the other 50 MSQA sites were selected as targeted sites to more evenly cover agricultural and urban stressor gradients in the study area. Of the 50 targeted sites, 12 were in urbanized watersheds and 21 represented “good” biological conditions or “least disturbed” conditions. The remaining 17 targeted sites were selected to improve coverage of the agricultural intensity gradient or because of historical data collection to provide temporal context for the

  17. Development and Validation of Assessing Quality Teaching Rubrics

    ERIC Educational Resources Information Center

    Chen, Weiyun; Mason, Steve; Hammond-Bennett, Austin; Zlamout, Sandy

    2014-01-01

    Purpose: This study aimed at examining the psychometric properties of the Assessing Quality Teaching Rubric (AQTR) that was designed to assess in-service teachers' quality levels of teaching practices in daily lessons. Methods: 45 physical education lessons taught by nine physical education teachers to students in grades K-5 were videotaped. They…

  18. Image Quality Ranking Method for Microscopy

    PubMed Central

    Koho, Sami; Fazeli, Elnaz; Eriksson, John E.; Hänninen, Pekka E.

    2016-01-01

    Automated analysis of microscope images is necessitated by the increased need for high-resolution follow up of events in time. Manually finding the right images to be analyzed, or eliminated from data analysis are common day-to-day problems in microscopy research today, and the constantly growing size of image datasets does not help the matter. We propose a simple method and a software tool for sorting images within a dataset, according to their relative quality. We demonstrate the applicability of our method in finding good quality images in a STED microscope sample preparation optimization image dataset. The results are validated by comparisons to subjective opinion scores, as well as five state-of-the-art blind image quality assessment methods. We also show how our method can be applied to eliminate useless out-of-focus images in a High-Content-Screening experiment. We further evaluate the ability of our image quality ranking method to detect out-of-focus images, by extensive simulations, and by comparing its performance against previously published, well-established microscopy autofocus metrics. PMID:27364703

  19. Feasibility of peer assessment and clinical audit to self-regulate the quality of physiotherapy services: a mixed methods study

    PubMed Central

    Nijhuis-van der Sanden, Maria W G; Driehuis, Femke; Heerkens, Yvonne F; van der Vleuten, Cees P M; van der Wees, Philip J

    2017-01-01

    Objectives To evaluate the feasibility of a quality improvement programme aimed to enhance the client-centeredness, effectiveness and transparency of physiotherapy services by addressing three feasibility domains: (1) acceptability of the programme design, (2) appropriateness of the implementation strategy and (3) impact on quality improvement. Design Mixed methods study. Participants and setting 64 physiotherapists working in primary care, organised in a network of communities of practice in the Netherlands. Methods The programme contained: (1) two cycles of online self-assessment and peer assessment (PA) of clinical performance using client records and video-recordings of client communication followed by face-to-face group discussions, and (2) clinical audit assessing organisational performance. Assessment was based on predefined performance indicators which could be scored on a 5-point Likert scale. Discussions addressed performance standards and scoring differences. All feasibility domains were evaluated qualitatively with two focus groups and 10 in-depth interviews. In addition, we evaluated the impact on quality improvement quantitatively by comparing self-assessment and PA scores in cycles 1 and 2. Results We identified critical success features relevant to programme development and implementation, such as clarifying expectations at baseline, training in PA skills, prolonged engagement with video-assessment and competent group coaches. Self-reported impact on quality improvement included awareness of clinical and organisational performance, improved evidence-based practice and client-centeredness and increased motivation to self-direct quality improvement. Differences between self-scores and peer scores on performance indicators were not significant. Between cycles 1 and 2, scores for record keeping showed significant improvement, however not for client communication. Conclusions This study demonstrated that bottom-up initiatives to improve healthcare

  20. Criteria for assessment of bridge aesthetic and visual quality

    NASA Astrophysics Data System (ADS)

    Rozentale, I.; Paeglitis, A.

    2017-10-01

    The bridge designers should find an ideal balance between structure, economy, buildability, aesthetics, durability and harmony with industrial or natural landscape. During the last years, the society has adopted documents providing procedures for evaluation of the impact of the structural appearance on surrounding landscape. The European Landscape Convention defines the landscape as an area perceived by people, whose character is the result of the action and interaction of natural and/or human factors. The Convention indicates the methods for clear and objective assessment of the landscape’s visual qualities. The esthetical qualities of bridge structures, appearance and attraction should satisfy not only the technicians - engineers and architects, but mostly the surrounding population. Each of these groups has a different perception of esthetical qualities of structure. Many authors have used different methods and criteria for assessment of bridge aesthetics. The aim of this paper is to provide an overview of the bridge aesthetic and visual quality assessment methods and criteria.

  1. Protein single-model quality assessment by feature-based probability density functions.

    PubMed

    Cao, Renzhi; Cheng, Jianlin

    2016-04-04

    Protein quality assessment (QA) has played an important role in protein structure prediction. We developed a novel single-model quality assessment method-Qprob. Qprob calculates the absolute error for each protein feature value against the true quality scores (i.e. GDT-TS scores) of protein structural models, and uses them to estimate its probability density distribution for quality assessment. Qprob has been blindly tested on the 11th Critical Assessment of Techniques for Protein Structure Prediction (CASP11) as MULTICOM-NOVEL server. The official CASP result shows that Qprob ranks as one of the top single-model QA methods. In addition, Qprob makes contributions to our protein tertiary structure predictor MULTICOM, which is officially ranked 3rd out of 143 predictors. The good performance shows that Qprob is good at assessing the quality of models of hard targets. These results demonstrate that this new probability density distribution based method is effective for protein single-model quality assessment and is useful for protein structure prediction. The webserver of Qprob is available at: http://calla.rnet.missouri.edu/qprob/. The software is now freely available in the web server of Qprob.

  2. Video conference quality assessment based on cooperative sensing of video and audio

    NASA Astrophysics Data System (ADS)

    Wang, Junxi; Chen, Jialin; Tian, Xin; Zhou, Cheng; Zhou, Zheng; Ye, Lu

    2015-12-01

    This paper presents a method to video conference quality assessment, which is based on cooperative sensing of video and audio. In this method, a proposed video quality evaluation method is used to assess the video frame quality. The video frame is divided into noise image and filtered image by the bilateral filters. It is similar to the characteristic of human visual, which could also be seen as a low-pass filtering. The audio frames are evaluated by the PEAQ algorithm. The two results are integrated to evaluate the video conference quality. A video conference database is built to test the performance of the proposed method. It could be found that the objective results correlate well with MOS. Then we can conclude that the proposed method is efficiency in assessing video conference quality.

  3. Improved model quality assessment using ProQ2.

    PubMed

    Ray, Arjun; Lindahl, Erik; Wallner, Björn

    2012-09-10

    Employing methods to assess the quality of modeled protein structures is now standard practice in bioinformatics. In a broad sense, the techniques can be divided into methods relying on consensus prediction on the one hand, and single-model methods on the other. Consensus methods frequently perform very well when there is a clear consensus, but this is not always the case. In particular, they frequently fail in selecting the best possible model in the hard cases (lacking consensus) or in the easy cases where models are very similar. In contrast, single-model methods do not suffer from these drawbacks and could potentially be applied on any protein of interest to assess quality or as a scoring function for sampling-based refinement. Here, we present a new single-model method, ProQ2, based on ideas from its predecessor, ProQ. ProQ2 is a model quality assessment algorithm that uses support vector machines to predict local as well as global quality of protein models. Improved performance is obtained by combining previously used features with updated structural and predicted features. The most important contribution can be attributed to the use of profile weighting of the residue specific features and the use features averaged over the whole model even though the prediction is still local. ProQ2 is significantly better than its predecessors at detecting high quality models, improving the sum of Z-scores for the selected first-ranked models by 20% and 32% compared to the second-best single-model method in CASP8 and CASP9, respectively. The absolute quality assessment of the models at both local and global level is also improved. The Pearson's correlation between the correct and local predicted score is improved from 0.59 to 0.70 on CASP8 and from 0.62 to 0.68 on CASP9; for global score to the correct GDT_TS from 0.75 to 0.80 and from 0.77 to 0.80 again compared to the second-best single methods in CASP8 and CASP9, respectively. ProQ2 is available at http://proq2

  4. Quality Assurance--Best Practices for Assessing Online Programs

    ERIC Educational Resources Information Center

    Wang, Qi

    2006-01-01

    Educators have long sought to define quality in education. With the proliferation of distance education and online learning powered by the Internet, the tasks required to assess the quality of online programs become even more challenging. To assist educators and institutions in search of quality assurance methods to continuously improve their…

  5. Designing a Method with Physician Participation to Assess and Improve Quality of Healthcare in Otolaryngology.

    PubMed

    Arce, José M; Martín Cleary, Catalina; Cenjor, Carlos; Ramos, Ángel; Ortiz, Alberto

    2017-04-01

    Patient choice of healthcare centers to be treated for specific diseases is compromised by the low accessibility of understandable information. Physicians are rarely involved in healthcare quality assessment, despite their potentially valuable input. The purpose of this study was to develop a methodology for evaluating the quality of care that specifically incorporates advice from medical specialists and provides accessible information for patients in search of high-quality healthcare. A pilot Delphi study was conducted among 28 Spanish otolaryngology experts, seeking their opinion on the quality-of-care indicators and on their ability to recommend the most suitable department for the treatment of specific otolaryngologic diseases. The average acceptance rate was 91.9% for quality-of-care indicator and 96.5% for the resources needed for improving the quality of care. Furthermore, 93% experts reported that patients frequently ask for physician advice on which center provides better care for a specific disease, 92.6% experts believe they could recommend the best centers for specific otolaryngologic diseases, and 80% experts agreed that expert opinion on the quality of care offered by different centers would be a valuable addition to quality-of-care assessment. The incorporation of physician advice into healthcare quality assessment may improve the usefulness of healthcare quality indicators for patients. Assessment tools incorporating physician advice should be developed and validated.

  6. Assessment of air quality microsensors versus reference methods: The EuNetAir joint exercise

    NASA Astrophysics Data System (ADS)

    Borrego, C.; Costa, A. M.; Ginja, J.; Amorim, M.; Coutinho, M.; Karatzas, K.; Sioumis, Th.; Katsifarakis, N.; Konstantinidis, K.; De Vito, S.; Esposito, E.; Smith, P.; André, N.; Gérard, P.; Francis, L. A.; Castell, N.; Schneider, P.; Viana, M.; Minguillón, M. C.; Reimringer, W.; Otjes, R. P.; von Sicard, O.; Pohle, R.; Elen, B.; Suriano, D.; Pfister, V.; Prato, M.; Dipinto, S.; Penza, M.

    2016-12-01

    The 1st EuNetAir Air Quality Joint Intercomparison Exercise organized in Aveiro (Portugal) from 13th-27th October 2014, focused on the evaluation and assessment of environmental gas, particulate matter (PM) and meteorological microsensors, versus standard air quality reference methods through an experimental urban air quality monitoring campaign. The IDAD-Institute of Environment and Development Air Quality Mobile Laboratory was placed at an urban traffic location in the city centre of Aveiro to conduct continuous measurements with standard equipment and reference analysers for CO, NOx, O3, SO2, PM10, PM2.5, temperature, humidity, wind speed and direction, solar radiation and precipitation. The comparison of the sensor data generated by different microsensor-systems installed side-by-side with reference analysers, contributes to the assessment of the performance and the accuracy of microsensor-systems in a real-world context, and supports their calibration and further development. The overall performance of the sensors in terms of their statistical metrics and measurement profile indicates significant differences in the results depending on the platform and on the sensors considered. In terms of pollutants, some promising results were observed for O3 (r2: 0.12-0.77), CO (r2: 0.53-0.87), and NO2 (r2: 0.02-0.89). For PM (r2: 0.07-0.36) and SO2 (r2: 0.09-0.20) the results show a poor performance with low correlation coefficients between the reference and microsensor measurements. These field observations under specific environmental conditions suggest that the relevant microsensor platforms, if supported by the proper post processing and data modelling tools, have enormous potential for new strategies in air quality control.

  7. Rating methodological quality: toward improved assessment and investigation.

    PubMed

    Moyer, Anne; Finney, John W

    2005-01-01

    Assessing methodological quality is considered essential in deciding what investigations to include in research syntheses and in detecting potential sources of bias in meta-analytic results. Quality assessment is also useful in characterizing the strengths and limitations of the research in an area of study. Although numerous instruments to measure research quality have been developed, they have lacked empirically-supported components. In addition, different summary quality scales have yielded different findings when they were used to weight treatment effect estimates for the same body of research. Suggestions for developing improved quality instruments include: distinguishing distinct domains of quality, such as internal validity, external validity, the completeness of the study report, and adherence to ethical practices; focusing on individual aspects, rather than domains of quality; and focusing on empirically-verified criteria. Other ways to facilitate the constructive use of quality assessment are to improve and standardize the reporting of research investigations, so that the quality of studies can be more equitably and thoroughly compared, and to identify optimal methods for incorporating study quality ratings into meta-analyses.

  8. Application of chemometric methods for assessment and modelling of microbiological quality data concerning coastal bathing water in Greece.

    PubMed

    Papaioannou, Agelos; Rigas, George; Papastergiou, Panagiotis; Hadjichristodoulou, Christos

    2014-12-02

    Worldwide, the aim of managing water is to safeguard human health whilst maintaining sustainable aquatic and associated terrestrial, ecosystems. Because human enteric viruses are the most likely pathogens responsible for waterborne diseases from recreational water use, but detection methods are complex and costly for routine monitoring, it is of great interest to determine the quality of coastal bathing water with a minimum cost and maximum safety. This study handles the assessment and modelling of the microbiological quality data of 2149 seawater bathing areas in Greece over 10-year period (1997-2006) by chemometric methods. Cluster analysis results indicated that the studied bathing beaches are classified in accordance with the seasonality in three groups. Factor analysis was applied to investigate possible determining factors in the groups resulted from the cluster analysis, and also two new parameters were created in each group; VF1 includes E. coli, faecal coliforms and total coliforms and VF2 includes faecal streptococci/enterococci. By applying the cluster analysis in each seasonal group, three new groups of coasts were generated, group A (ultraclean), group B (clean) and group C (contaminated). The above analysis is confirmed by the application of discriminant analysis, and proves that chemometric methods are useful tools for assessment and modeling microbiological quality data of coastal bathing water on a large scale, and thus could attribute to effective and economical monitoring of the quality of coastal bathing water in a country with a big number of bathing coasts, like Greece. Significance for public healthThe microbiological protection of coastal bathing water quality is of great interest for the public health authorities as well as for the economy. The present study proves that this protection can be achieved by monitoring only two microbiological parameters, E. coli and faecal streptococci/enterococci instead four microbiological parameters (the

  9. [An integrated assessment method of ecological quality status in coastal waters: taking Tong'an Bay as a case].

    PubMed

    Chen, Zhao-hua; Wu, Hai-yan; Chen, Ke-liang; Chen, Qing-hui; Wu, Ji-chun; Zhang, Jing-fei

    2011-07-01

    Based on the integrated assessment methods of ecological quality status (EcoQS) in coastal waters abroad as well as the domestic related research status, 11 indices were selected from the biotic and physicochemical elements of water and sediment to built an integrated EcoQS assessment index system, and, with the comprehensive consideration of domestic and international evaluation standards, 5 levels of EcoQS classified as "high, good, moderate, poor, and bad" were determined. Then, an integrated assessment method of EcoQS in coastal waters was established by using analytic hierarchy process (AHP) and fuzzy mathematics method, and tested by the analysis of the correlations between the EcoQS grade and the major anthropogenic disturbances and pollutant concentrations of Tong' an Bay. The EcoQS of Tong' an Bay was assessed as moderate, i.e., the Bay was moderately disturbed and in transitional to poor status. The established integrated assessment method could not only reflect the major anthropogenic environmental pressure and risk factors, but also give an early warning of the pollutants satisfied by law in the study area.

  10. Method of radiometric quality assessment of NIR images acquired with a custom sensor mounted on an unmanned aerial vehicle

    NASA Astrophysics Data System (ADS)

    Wierzbicki, Damian; Fryskowska, Anna; Kedzierski, Michal; Wojtkowska, Michalina; Delis, Paulina

    2018-01-01

    Unmanned aerial vehicles are suited to various photogrammetry and remote sensing missions. Such platforms are equipped with various optoelectronic sensors imaging in the visible and infrared spectral ranges and also thermal sensors. Nowadays, near-infrared (NIR) images acquired from low altitudes are often used for producing orthophoto maps for precision agriculture among other things. One major problem results from the application of low-cost custom and compact NIR cameras with wide-angle lenses introducing vignetting. In numerous cases, such cameras acquire low radiometric quality images depending on the lighting conditions. The paper presents a method of radiometric quality assessment of low-altitude NIR imagery data from a custom sensor. The method utilizes statistical analysis of NIR images. The data used for the analyses were acquired from various altitudes in various weather and lighting conditions. An objective NIR imagery quality index was determined as a result of the research. The results obtained using this index enabled the classification of images into three categories: good, medium, and low radiometric quality. The classification makes it possible to determine the a priori error of the acquired images and assess whether a rerun of the photogrammetric flight is necessary.

  11. Category 1 external quality assessment program for serum creatinine.

    PubMed

    González-Lao, Elisabet; Díaz-Garzón, Jorge; Corte, Zoraida; Ricós, Carmen; Perich, Carmen; Álvarez, Virtudes; Simón, Margarita; Minchinela, Joana; García-Lario, José Vicente; Boned, Beatriz; Biosca, Carmen; Cava, Fernando; Fernández-Fernández, Pilar; Fernández-Calle, Pilar

    2017-03-01

    The Commission of Analytical Quality and the Committee of External Quality Programs of Spanish Society of Laboratory Medicine (SEQC) in collaboration with the Dutch Foundation for the Quality organized the first national category 1 External Quality Assessment Programs (EQAP) pilot study. The aim is to evaluate the standardization of serum creatinine measurements in the Spanish laboratories through a category 1 external quality assurance program with commutable material and reference method assigned values. A total of 87 Spanish laboratories were involved in this program in 2015. Each day a sample control was measured by duplicate during 6 consecutive days. Percentage deviations and coefficients of variation obtained were compared with quality specifications derived from biological variation. A total of 1044 creatinine results were obtained. Laboratories were coded in 11 different method-traceability combinations. Only enzymatic methods get all results within the acceptability limits. To participate in a category 1 EQAP is a valuable tool to assess the standardization degree in our country; a big effort should be made to promote laboratories to change their procedures and to use enzymatic creatinine methods, in order to achieve a satisfactory standardization degree for this important analyte.

  12. Validation of selected analytical methods using accuracy profiles to assess the impact of a Tobacco Heating System on indoor air quality.

    PubMed

    Mottier, Nicolas; Tharin, Manuel; Cluse, Camille; Crudo, Jean-René; Lueso, María Gómez; Goujon-Ginglinger, Catherine G; Jaquier, Anne; Mitova, Maya I; Rouget, Emmanuel G R; Schaller, Mathieu; Solioz, Jennifer

    2016-09-01

    Studies in environmentally controlled rooms have been used over the years to assess the impact of environmental tobacco smoke on indoor air quality. As new tobacco products are developed, it is important to determine their impact on air quality when used indoors. Before such an assessment can take place it is essential that the analytical methods used to assess indoor air quality are validated and shown to be fit for their intended purpose. Consequently, for this assessment, an environmentally controlled room was built and seven analytical methods, representing eighteen analytes, were validated. The validations were carried out with smoking machines using a matrix-based approach applying the accuracy profile procedure. The performances of the methods were compared for all three matrices under investigation: background air samples, the environmental aerosol of Tobacco Heating System THS 2.2, a heat-not-burn tobacco product developed by Philip Morris International, and the environmental tobacco smoke of a cigarette. The environmental aerosol generated by the THS 2.2 device did not have any appreciable impact on the performances of the methods. The comparison between the background and THS 2.2 environmental aerosol samples generated by smoking machines showed that only five compounds were higher when THS 2.2 was used in the environmentally controlled room. Regarding environmental tobacco smoke from cigarettes, the yields of all analytes were clearly above those obtained with the other two air sample types. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  13. Image Quality Assessment of High-Resolution Satellite Images with Mtf-Based Fuzzy Comprehensive Evaluation Method

    NASA Astrophysics Data System (ADS)

    Wu, Z.; Luo, Z.; Zhang, Y.; Guo, F.; He, L.

    2018-04-01

    A Modulation Transfer Function (MTF)-based fuzzy comprehensive evaluation method was proposed in this paper for the purpose of evaluating high-resolution satellite image quality. To establish the factor set, two MTF features and seven radiant features were extracted from the knife-edge region of image patch, which included Nyquist, MTF0.5, entropy, peak signal to noise ratio (PSNR), average difference, edge intensity, average gradient, contrast and ground spatial distance (GSD). After analyzing the statistical distribution of above features, a fuzzy evaluation threshold table and fuzzy evaluation membership functions was established. The experiments for comprehensive quality assessment of different natural and artificial objects was done with GF2 image patches. The results showed that the calibration field image has the highest quality scores. The water image has closest image quality to the calibration field, quality of building image is a little poor than water image, but much higher than farmland image. In order to test the influence of different features on quality evaluation, the experiment with different weights were tested on GF2 and SPOT7 images. The results showed that different weights correspond different evaluating effectiveness. In the case of setting up the weights of edge features and GSD, the image quality of GF2 is better than SPOT7. However, when setting MTF and PSNR as main factor, the image quality of SPOT7 is better than GF2.

  14. Factors Influencing Assessment Quality in Higher Vocational Education

    ERIC Educational Resources Information Center

    Baartman, Liesbeth; Gulikers, Judith; Dijkstra, Asha

    2013-01-01

    The development of assessments that are fit to assess professional competence in higher vocational education requires a reconsideration of assessment methods, quality criteria and (self)evaluation. This article examines the self-evaluations of nine courses of a large higher vocational education institute. Per course, 4-11 teachers and 3-10…

  15. PconsD: ultra rapid, accurate model quality assessment for protein structure prediction.

    PubMed

    Skwark, Marcin J; Elofsson, Arne

    2013-07-15

    Clustering methods are often needed for accurately assessing the quality of modeled protein structures. Recent blind evaluation of quality assessment methods in CASP10 showed that there is little difference between many different methods as far as ranking models and selecting best model are concerned. When comparing many models, the computational cost of the model comparison can become significant. Here, we present PconsD, a fast, stream-computing method for distance-driven model quality assessment that runs on consumer hardware. PconsD is at least one order of magnitude faster than other methods of comparable accuracy. The source code for PconsD is freely available at http://d.pcons.net/. Supplementary benchmarking data are also available there. arne@bioinfo.se Supplementary data are available at Bioinformatics online.

  16. Parasitology: United Kingdom National Quality Assessment Scheme.

    PubMed Central

    Hawthorne, M.; Chiodini, P. L.; Snell, J. J.; Moody, A. H.; Ramsay, A.

    1992-01-01

    AIMS: To assess the results from parasitology laboratories taking part in a quality assessment scheme between 1986 and 1991; and to compare performance with repeat specimens. METHODS: Quality assessment of blood parasitology, including tissue parasites (n = 444; 358 UK, 86 overseas), and faecal parasitology, including extra-intestinal parasites (n = 205; 141 UK, 64 overseas), was performed. RESULTS: Overall, the standard of performance was poor. A questionnaire distributed to participants showed that a wide range of methods was used, some of which were considered inadequate to achieve reliable results. Teaching material was distributed to participants from time to time in an attempt to improve standards. CONCLUSIONS: Since the closure of the IMLS fellowship course in 1972, fewer opportunities for specialised training in parasitology are available: more training is needed. Poor performance in the detection of malarial parasites is mainly attributable to incorrect speciation, misidentification, and lack of equipment such as an eyepiece graticule. PMID:1452791

  17. Dynamic Assessment of Water Quality Based on a Variable Fuzzy Pattern Recognition Model

    PubMed Central

    Xu, Shiguo; Wang, Tianxiang; Hu, Suduan

    2015-01-01

    Water quality assessment is an important foundation of water resource protection and is affected by many indicators. The dynamic and fuzzy changes of water quality lead to problems for proper assessment. This paper explores a method which is in accordance with the water quality changes. The proposed method is based on the variable fuzzy pattern recognition (VFPR) model and combines the analytic hierarchy process (AHP) model with the entropy weight (EW) method. The proposed method was applied to dynamically assess the water quality of Biliuhe Reservoir (Dailan, China). The results show that the water quality level is between levels 2 and 3 and worse in August or September, caused by the increasing water temperature and rainfall. Weights and methods are compared and random errors of the values of indicators are analyzed. It is concluded that the proposed method has advantages of dynamism, fuzzification and stability by considering the interval influence of multiple indicators and using the average level characteristic values of four models as results. PMID:25689998

  18. Dynamic assessment of water quality based on a variable fuzzy pattern recognition model.

    PubMed

    Xu, Shiguo; Wang, Tianxiang; Hu, Suduan

    2015-02-16

    Water quality assessment is an important foundation of water resource protection and is affected by many indicators. The dynamic and fuzzy changes of water quality lead to problems for proper assessment. This paper explores a method which is in accordance with the water quality changes. The proposed method is based on the variable fuzzy pattern recognition (VFPR) model and combines the analytic hierarchy process (AHP) model with the entropy weight (EW) method. The proposed method was applied to dynamically assess the water quality of Biliuhe Reservoir (Dailan, China). The results show that the water quality level is between levels 2 and 3 and worse in August or September, caused by the increasing water temperature and rainfall. Weights and methods are compared and random errors of the values of indicators are analyzed. It is concluded that the proposed method has advantages of dynamism, fuzzification and stability by considering the interval influence of multiple indicators and using the average level characteristic values of four models as results.

  19. Linking fish tolerance to water quality criteria for the assessment of environmental flows: A practical method for streamflow regulation and pollution control.

    PubMed

    Zhao, Changsen; Yang, Shengtian; Liu, Junguo; Liu, Changming; Hao, Fanghua; Wang, Zhonggen; Zhang, Huitong; Song, Jinxi; Mitrovic, Simon M; Lim, Richard P

    2018-05-15

    The survival of aquatic biota in stream ecosystems depends on both water quantity and quality, and is particularly susceptible to degraded water quality in regulated rivers. Maintenance of environmental flows (e-flows) for aquatic biota with optimum water quantity and quality is essential for sustainable ecosystem services, especially in developing regions with insufficient stream monitoring of hydrology, water quality and aquatic biota. Few e-flow methods are available that closely link aquatic biota tolerances to pollutant concentrations in a simple and practical manner. In this paper a new method was proposed to assess e-flows that aimed to satisfy the requirements of aquatic biota for both the quantity and quality of the streamflow by linking fish tolerances to water quality criteria, or the allowable concentration of pollutants. For better operation of water projects and control of pollutants discharged into streams, this paper presented two coefficients for streamflow adjustment and pollutant control. Assessment of e-flows in the Wei River, the largest tributary of the Yellow River, shows that streamflow in dry seasons failed to meet e-flow requirements. Pollutant influx exerted a large pressure on the aquatic ecosystem, with pollutant concentrations much higher than that of the fish tolerance thresholds. We found that both flow velocity and water temperature exerted great influences on the pollutant degradation rate. Flow velocity had a much greater influence on pollutant degradation than did the standard deviation of flow velocity. This study provides new methods to closely link the tolerance of aquatic biota to water quality criteria for e-flow assessment. The recommended coefficients for streamflow adjustment and pollutant control, to dynamically regulate streamflow and control pollutant discharge, are helpful for river management and ecosystems rehabilitation. The relatively low data requirement also makes the method easy to use efficiently in developing

  20. Feasibility of peer assessment and clinical audit to self-regulate the quality of physiotherapy services: a mixed methods study.

    PubMed

    Maas, Marjo J M; Nijhuis-van der Sanden, Maria W G; Driehuis, Femke; Heerkens, Yvonne F; van der Vleuten, Cees P M; van der Wees, Philip J

    2017-02-10

    To evaluate the feasibility of a quality improvement programme aimed to enhance the client-centeredness, effectiveness and transparency of physiotherapy services by addressing three feasibility domains: (1) acceptability of the programme design, (2) appropriateness of the implementation strategy and (3) impact on quality improvement. Mixed methods study. 64 physiotherapists working in primary care, organised in a network of communities of practice in the Netherlands. The programme contained: (1) two cycles of online self-assessment and peer assessment (PA) of clinical performance using client records and video-recordings of client communication followed by face-to-face group discussions, and (2) clinical audit assessing organisational performance. Assessment was based on predefined performance indicators which could be scored on a 5-point Likert scale. Discussions addressed performance standards and scoring differences. All feasibility domains were evaluated qualitatively with two focus groups and 10 in-depth interviews. In addition, we evaluated the impact on quality improvement quantitatively by comparing self-assessment and PA scores in cycles 1 and 2. We identified critical success features relevant to programme development and implementation, such as clarifying expectations at baseline, training in PA skills, prolonged engagement with video-assessment and competent group coaches. Self-reported impact on quality improvement included awareness of clinical and organisational performance, improved evidence-based practice and client-centeredness and increased motivation to self-direct quality improvement. Differences between self-scores and peer scores on performance indicators were not significant. Between cycles 1 and 2, scores for record keeping showed significant improvement, however not for client communication. This study demonstrated that bottom-up initiatives to improve healthcare quality can be effective. The results justify ongoing evaluation to inform

  1. Testing the extended biotic index in Slovakia: consistency, advantages, and limitations versus the saprobic assessment method of water quality.

    PubMed

    Pennelli, Bruno; Nagel, Karl-Otto; Crivellaro, Giuseppe; Fabiani, Claudio; Vancova, Alexandra; Mancini, Laura

    2006-04-01

    The European Union Water Framework Directive requires the achievement of environmental objectives for the ecological quality of water bodies. A comparable implementation of the Directive throughout member countries of the European Union is necessary to verify equal protection of surface waters. The Directive specifies that member states determine ecological quality by means of biological indices. To improve comparability of water quality assessment, this research carried out an intercalibration trial between the Slovak Saprobic Index and the Italian protocol of the Extended Biotic Index, as part of a cooperative program between Italy and the Slovak Republic. When assessing streams with no or low pollution, statistics showed similar results for both methods. In contrast, the comparison of indices was not accurate in the case of severely affected waters. Reliable conversion formulas are feasible to transform the Italian Extended Biotic Index into the Slovak Saprobic Index, and not vice versa.

  2. Assessment of different methods to estimate bovine colostrum quality on farm.

    PubMed

    Bartens, M-C; Drillich, M; Rychli, K; Iwersen, M; Arnholdt, T; Meyer, L; Klein-Jöbstl, D

    2016-09-01

    To evaluate two different hydrometers and an optical and a digital Brix refractometer for the assessment of bovine colostrum quality, in terms of accuracy and precision compared with the measurement of IgG concentrations using radial immunodiffusion (RID), and to evaluate the reliability and repeatability of the Brix refractometers. To determine reliability and repeatability, 145 colostrum samples were tested by two independent observers twice, using the optical and digital Brix refractometers. A further 193 colostrum samples from Holstein cows were collected on one commercial dairy farm at first milking and tested with two hydrometers and an optical and digital Brix refractometer. An aliquot of each sample was frozen for RID measurement of IgG concentrations and samples were classified as poor (≤50 g IgG/L) or good (>50 g IgG/L) quality colostrum. Intraclass correlation coefficients (ICC) were used to determine inter- and intra-observer reliability and repeatability. Optimised cut-off values for the four devices were determined using receiver operating characteristics (ROC) analysis with the RID results as the reference. Using these cut-offs, sensitivities and specificities for determining good quality colostrum were calculated. The ICC for inter-observer reliability was 0.98 for the optical Brix refractometer, and for intra-observer repeatability was 0.97 and 0.98 for the optical and the digital Brix refractometers, respectively. For the 193 colostrum samples, 67 (34.7%) had concentrations of IgG ≤50 g/L determined by RID. Optimised cut-off values evaluated by ROC analysis were higher for all devices compared with manufacturer reference or previously published values. Using these values, the sensitivities for the two hydrometers, and the optical and the digital Brix refractometers were 0.73, 0.71, 0.56 and 0.79, respectively; specificities were 0.72, 0.61, 0.90 and 0.69, respectively. The Brix refractometers provided the most accurate assessment of

  3. Evaluation for the ecological quality status of coastal waters in East China Sea using fuzzy integrated assessment method.

    PubMed

    Wu, H Y; Chen, K L; Chen, Z H; Chen, Q H; Qiu, Y P; Wu, J C; Zhang, J F

    2012-03-01

    This research presented an evaluation for the ecological quality status (EcoQS) of three semi-enclosed coastal areas using fuzzy integrated assessment method (FIAM). With this method, the hierarchy structure was clarified by an index system of 11 indicators selected from biotic elements and physicochemical elements, and the weight vector of index system was calculated with Delphi-Analytic Hierarchy Process (AHP) procedure. Then, the FIAM was used to achieve an EcoQS assessment. As a result of assessment, most of the sampling stations demonstrated a clear gradient in EcoQS, ranging from high to poor status. Among the four statuses, high and good, owning a ratio of 55.9% and 26.5%, respectively, were two dominant statuses for three bays, especially for Sansha Bay and Luoyuan Bay. The assessment results were found consistent with the pressure information and parameters obtained at most stations. In addition, the sources of uncertainty in classification of EcoQS were also discussed. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Comparability of fish-based ecological quality assessments for geographically distinct Iberian regions.

    PubMed

    Segurado, P; Caiola, N; Pont, D; Oliveira, J M; Delaigue, O; Ferreira, M T

    2014-04-01

    In this work we compare two Iberian and a pan-European fish-based methods to assess ecological quality in rivers: the Fish-based Index of Biotic Integrity for Portuguese Wadeable Streams (F-IBIP), the Mediterranean Index of Biotic Integrity (IBIMED) and the pan-European Fish Index (EFI+). The results presented herein were developed in the context of the 2nd phase of the Intercalibration Exercise (IC), as required by the Water Frame Directive (WFD). The IC is aimed at ensuring comparability of the quality boundaries among the different WFD assessment methods developed by the Member States for each biological quality element. Although the two national assessment methods were developed for very distinct regions of Iberia (Western and Eastern Iberian Peninsula) they share the same methodological background: both are type-specific and guild-based multimetric indices. EFI+ is a multimetric guild-based model, but it is site-specific and uses a predictive modelling approach. The three indices were computed for all sites included in the Iberian Intercalibration database to allow the direct comparison, by means of linear regressions, of the resulting three quality values per site. The quality boundary harmonization between the two Iberian methods was only possible through an indirect comparison between the two indices, using EFI+ as a common metric. The three indices were also shown to be responsive to a common set of human induced pressures. This study highlights the need to develop general assessment methods adapted to wide geographical ranges with high species turnover to help intercalibrating assessment methods tailored for geographically more restricted regions. © 2013.

  5. Soil structural quality assessment for soil protection regulation

    NASA Astrophysics Data System (ADS)

    Johannes, Alice; Boivin, Pascal

    2017-04-01

    Soil quality assessment is rapidly developing worldwide, though mostly focused on the monitoring of arable land and soil fertility. Soil protection regulations assess soil quality differently, focusing on priority pollutants and threshold values. The soil physical properties are weakly considered, due to lack of consensus and experimental difficulties faced with characterization. Non-disputable, easy to perform and inexpensive methods should be available for environmental regulation to be applied, which is unfortunately not the case. As a consequence, quantitative soil physical protection regulation is not applied, and inexpensive soil physical quality indicators for arable soil management are not available. Overcoming these limitations was the objective of a research project funded by the Swiss federal office for environment (FOEN). The main results and the perspectives of application are given in this presentation. A first step of the research was to characterize soils in a good structural state (reference soils) under different land use. The structural quality was assessed with field expertise and Visual Evaluation of the Soil Structure (VESS), and the physical properties were assessed with Shrinkage analysis. The relationships between the physical properties and the soil constituents were linear and highly determined. They represent the reference properties of the corresponding soils. In a second step, the properties of physically degraded soils were analysed and compared to the reference properties. This allowed defining the most discriminant parameters departing the different structure qualities and their threshold limits. Equivalent properties corresponding to these parameters but inexpensive and easy to determine were defined and tested. More than 90% of the samples were correctly classed with this method, which meets, therefore, the requirements for practical application in regulation. Moreover, result-oriented agri-environmental schemes for soil quality

  6. A research review of quality assessment for software

    NASA Technical Reports Server (NTRS)

    1991-01-01

    Measures were recommended to assess the quality of software submitted to the AdaNet program. The quality factors that are important to software reuse are explored and methods of evaluating those factors are discussed. Quality factors important to software reuse are: correctness, reliability, verifiability, understandability, modifiability, and certifiability. Certifiability is included because the documentation of many factors about a software component such as its efficiency, portability, and development history, constitute a class for factors important to some users, not important at all to other, and impossible for AdaNet to distinguish between a priori. The quality factors may be assessed in different ways. There are a few quantitative measures which have been shown to indicate software quality. However, it is believed that there exists many factors that indicate quality and have not been empirically validated due to their subjective nature. These subjective factors are characterized by the way in which they support the software engineering principles of abstraction, information hiding, modularity, localization, confirmability, uniformity, and completeness.

  7. Orion Entry Handling Qualities Assessments

    NASA Technical Reports Server (NTRS)

    Bihari, B.; Tiggers, M.; Strahan, A.; Gonzalez, R.; Sullivan, K.; Stephens, J. P.; Hart, J.; Law, H., III; Bilimoria, K.; Bailey, R.

    2011-01-01

    The Orion Command Module (CM) is a capsule designed to bring crew back from the International Space Station (ISS), the moon and beyond. The atmospheric entry portion of the flight is deigned to be flown in autopilot mode for nominal situations. However, there exists the possibility for the crew to take over manual control in off-nominal situations. In these instances, the spacecraft must meet specific handling qualities criteria. To address these criteria two separate assessments of the Orion CM s entry Handling Qualities (HQ) were conducted at NASA s Johnson Space Center (JSC) using the Cooper-Harper scale (Cooper & Harper, 1969). These assessments were conducted in the summers of 2008 and 2010 using the Advanced NASA Technology Architecture for Exploration Studies (ANTARES) six degree of freedom, high fidelity Guidance, Navigation, and Control (GN&C) simulation. This paper will address the specifics of the handling qualities criteria, the vehicle configuration, the scenarios flown, the simulation background and setup, crew interfaces and displays, piloting techniques, ratings and crew comments, pre- and post-fight briefings, lessons learned and changes made to improve the overall system performance. The data collection tools, methods, data reduction and output reports will also be discussed. The objective of the 2008 entry HQ assessment was to evaluate the handling qualities of the CM during a lunar skip return. A lunar skip entry case was selected because it was considered the most demanding of all bank control scenarios. Even though skip entry is not planned to be flown manually, it was hypothesized that if a pilot could fly the harder skip entry case, then they could also fly a simpler loads managed or ballistic (constant bank rate command) entry scenario. In addition, with the evaluation set-up of multiple tasks within the entry case, handling qualities ratings collected in the evaluation could be used to assess other scenarios such as the constant bank angle

  8. Design of a practical model-observer-based image quality assessment method for CT imaging systems

    NASA Astrophysics Data System (ADS)

    Tseng, Hsin-Wu; Fan, Jiahua; Cao, Guangzhi; Kupinski, Matthew A.; Sainath, Paavana

    2014-03-01

    The channelized Hotelling observer (CHO) is a powerful method for quantitative image quality evaluations of CT systems and their image reconstruction algorithms. It has recently been used to validate the dose reduction capability of iterative image-reconstruction algorithms implemented on CT imaging systems. The use of the CHO for routine and frequent system evaluations is desirable both for quality assurance evaluations as well as further system optimizations. The use of channels substantially reduces the amount of data required to achieve accurate estimates of observer performance. However, the number of scans required is still large even with the use of channels. This work explores different data reduction schemes and designs a new approach that requires only a few CT scans of a phantom. For this work, the leave-one-out likelihood (LOOL) method developed by Hoffbeck and Landgrebe is studied as an efficient method of estimating the covariance matrices needed to compute CHO performance. Three different kinds of approaches are included in the study: a conventional CHO estimation technique with a large sample size, a conventional technique with fewer samples, and the new LOOL-based approach with fewer samples. The mean value and standard deviation of area under ROC curve (AUC) is estimated by shuffle method. Both simulation and real data results indicate that an 80% data reduction can be achieved without loss of accuracy. This data reduction makes the proposed approach a practical tool for routine CT system assessment.

  9. Objective quality assessment for multiexposure multifocus image fusion.

    PubMed

    Hassen, Rania; Wang, Zhou; Salama, Magdy M A

    2015-09-01

    There has been a growing interest in image fusion technologies, but how to objectively evaluate the quality of fused images has not been fully understood. Here, we propose a method for objective quality assessment of multiexposure multifocus image fusion based on the evaluation of three key factors of fused image quality: 1) contrast preservation; 2) sharpness; and 3) structure preservation. Subjective experiments are conducted to create an image fusion database, based on which, performance evaluation shows that the proposed fusion quality index correlates well with subjective scores, and gives a significant improvement over the existing fusion quality measures.

  10. Quality assessment of protein model-structures using evolutionary conservation.

    PubMed

    Kalman, Matan; Ben-Tal, Nir

    2010-05-15

    Programs that evaluate the quality of a protein structural model are important both for validating the structure determination procedure and for guiding the model-building process. Such programs are based on properties of native structures that are generally not expected for faulty models. One such property, which is rarely used for automatic structure quality assessment, is the tendency for conserved residues to be located at the structural core and for variable residues to be located at the surface. We present ConQuass, a novel quality assessment program based on the consistency between the model structure and the protein's conservation pattern. We show that it can identify problematic structural models, and that the scores it assigns to the server models in CASP8 correlate with the similarity of the models to the native structure. We also show that when the conservation information is reliable, the method's performance is comparable and complementary to that of the other single-structure quality assessment methods that participated in CASP8 and that do not use additional structural information from homologs. A perl implementation of the method, as well as the various perl and R scripts used for the analysis are available at http://bental.tau.ac.il/ConQuass/. nirb@tauex.tau.ac.il Supplementary data are available at Bioinformatics online.

  11. APOLLO: a quality assessment service for single and multiple protein models.

    PubMed

    Wang, Zheng; Eickholt, Jesse; Cheng, Jianlin

    2011-06-15

    We built a web server named APOLLO, which can evaluate the absolute global and local qualities of a single protein model using machine learning methods or the global and local qualities of a pool of models using a pair-wise comparison approach. Based on our evaluations on 107 CASP9 (Critical Assessment of Techniques for Protein Structure Prediction) targets, the predicted quality scores generated from our machine learning and pair-wise methods have an average per-target correlation of 0.671 and 0.917, respectively, with the true model quality scores. Based on our test on 92 CASP9 targets, our predicted absolute local qualities have an average difference of 2.60 Å with the actual distances to native structure. http://sysbio.rnet.missouri.edu/apollo/. Single and pair-wise global quality assessment software is also available at the site.

  12. Assessing the quality of cost management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fayne, V.; McAllister, A.; Weiner, S.B.

    1995-12-31

    Managing environmental programs can be effective only when good cost and cost-related management practices are developed and implemented. The Department of Energy`s Office of Environmental Management (EM), recognizing this key role of cost management, initiated several cost and cost-related management activities including the Cost Quality Management (CQM) Program. The CQM Program includes an assessment activity, Cost Quality Management Assessments (CQMAs), and a technical assistance effort to improve program/project cost effectiveness. CQMAs provide a tool for establishing a baseline of cost-management practices and for measuring improvement in those practices. The result of the CQMA program is an organization that has anmore » increasing cost-consciousness, improved cost-management skills and abilities, and a commitment to respond to the public`s concerns for both a safe environment and prudent budget outlays. The CQMA program is part of the foundation of quality management practices in DOE. The CQMA process has contributed to better cost and cost-related management practices by providing measurements and feedback; defining the components of a quality cost-management system; and helping sites develop/improve specific cost-management techniques and methods.« less

  13. The Northeast Stream Quality Assessment

    USGS Publications Warehouse

    Van Metre, Peter C.; Riva-Murray, Karen; Coles, James F.

    2016-04-22

    In 2016, the U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) is assessing stream quality in the northeastern United States. The goal of the Northeast Stream Quality Assessment (NESQA) is to assess the quality of streams in the region by characterizing multiple water-quality factors that are stressors to aquatic life and evaluating the relation between these stressors and biological communities. The focus of NESQA in 2016 will be on the effects of urbanization and agriculture on stream quality in all or parts of eight states: Connecticut, Massachusetts, New Hampshire, New Jersey, New York, Pennsylvania, Rhode Island, and Vermont.Findings will provide the public and policymakers with information about the most critical factors affecting stream quality, thus providing insights about possible approaches to protect the health of streams in the region. The NESQA study will be the fourth regional study conducted as part of NAWQA and will be of similar design and scope to the first three, in the Midwest in 2013, the Southeast in 2014, and the Pacific Northwest in 2015 (http://txpub.usgs.gov/RSQA/).

  14. Comparison of outlier identification methods in hospital surgical quality improvement programs.

    PubMed

    Bilimoria, Karl Y; Cohen, Mark E; Merkow, Ryan P; Wang, Xue; Bentrem, David J; Ingraham, Angela M; Richards, Karen; Hall, Bruce L; Ko, Clifford Y

    2010-10-01

    Surgeons and hospitals are being increasingly assessed by third parties regarding surgical quality and outcomes, and much of this information is reported publicly. Our objective was to compare various methods used to classify hospitals as outliers in established surgical quality assessment programs by applying each approach to a single data set. Using American College of Surgeons National Surgical Quality Improvement Program data (7/2008-6/2009), hospital risk-adjusted 30-day morbidity and mortality were assessed for general surgery at 231 hospitals (cases = 217,630) and for colorectal surgery at 109 hospitals (cases = 17,251). The number of outliers (poor performers) identified using different methods and criteria were compared. The overall morbidity was 10.3% for general surgery and 25.3% for colorectal surgery. The mortality was 1.6% for general surgery and 4.0% for colorectal surgery. Programs used different methods (logistic regression, hierarchical modeling, partitioning) and criteria (P < 0.01, P < 0.05, P < 0.10) to identify outliers. Depending on outlier identification methods and criteria employed, when each approach was applied to this single dataset, the number of outliers ranged from 7 to 57 hospitals for general surgery morbidity, 1 to 57 hospitals for general surgery mortality, 4 to 27 hospitals for colorectal morbidity, and 0 to 27 hospitals for colorectal mortality. There was considerable variation in the number of outliers identified using different detection approaches. Quality programs seem to be utilizing outlier identification methods contrary to what might be expected, thus they should justify their methodology based on the intent of the program (i.e., quality improvement vs. reimbursement). Surgeons and hospitals should be aware of variability in methods used to assess their performance as these outlier designations will likely have referral and reimbursement consequences.

  15. Field trial of applicability of lot quality assurance sampling survey method for rapid assessment of prevalence of active trachoma.

    PubMed Central

    Myatt, Mark; Limburg, Hans; Minassian, Darwin; Katyola, Damson

    2003-01-01

    OBJECTIVE: To test the applicability of lot quality assurance sampling (LQAS) for the rapid assessment of the prevalence of active trachoma. METHODS: Prevalence of active trachoma in six communities was found by examining all children aged 2-5 years. Trial surveys were conducted in these communities. A sampling plan appropriate for classifying communities with prevalences < or =20% and > or =40% was applied to the survey data. Operating characteristic and average sample number curves were plotted, and screening test indices were calculated. The ability of LQAS to provide a three-class classification system was investigated. FINDINGS: Ninety-six trial surveys were conducted. All communities with prevalences < or =20% and > or =40% were identified correctly. The method discriminated between communities with prevalences < or =30% and >30%, with sensitivity of 98% (95% confidence interval (CI)=88.2-99.9%), specificity of 84.4% (CI=69.9-93.0%), positive predictive value of 87.7% (CI=75.7-94.5%), negative predictive value of 97.4% (CI=84.9-99.9%), and accuracy of 91.7% (CI=83.8-96.1%). Agreement between the three prevalence classes and survey classifications was 84.4% (CI=75.2-90.7%). The time needed to complete the surveys was consistent with the need to complete a survey in one day. CONCLUSION: Lot quality assurance sampling provides a method of classifying communities according to the prevalence of active trachoma. It merits serious consideration as a replacement for the assessment of the prevalence of active trachoma with the currently used trachoma rapid assessment method. It may be extended to provide a multi-class classification method. PMID:14997240

  16. [Quality assurance in geriatric rehabilitation--approaches and methods].

    PubMed

    Deckenbach, B; Borchelt, M; Steinhagen-Thiessen, E

    1997-08-01

    It did not take the provisions of the 5th Book of the Social Code for quality assurance issues to gain significance in the field of geriatric rehabilitation as well. While in the surgical specialties, experience in particular with external quality assurance have already been gathered over several years now, suitable concepts and methods for the new Geriatric Rehabilitation specialty are still in the initial stages of development. Proven methods from the industrial and service sectors, such as auditing, monitoring and quality circles, can in principle be drawn on for devising geriatric rehabilitation quality assurance schemes; these in particular need to take into account the multiple factors influencing the course and outcome of rehabilitation entailed by multimorbidity and multi-drug use; the eminent role of the social environment; therapeutic interventions by a multidisciplinary team; as well as the multi-dimensional nature of rehabilitation outcomes. Moreover, the specific conditions of geriatric rehabilitation require development not only of quality standards unique to this domain but also of quality assurance procedures specific to geriatrics. Along with a number of other methods, standardized geriatric assessment will play a crucial role in this respect.

  17. A quantitative method to analyze the quality of EIA information in wind energy development and avian/bat assessments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, Tony, E-mail: tc282@nau.edu; Nielsen, Erik, E-mail: erik.nielsen@nau.edu; Auberle, William, E-mail: william.auberle@nau.edu

    2013-01-15

    The environmental impact assessment (EIA) has been a tool for decision makers since the enactment of the National Environmental Policy Act (NEPA). Since that time, few analyses have been performed to verify the quality of information and content within EIAs. High quality information within assessments is vital in order for decision makers, stake holders, and the public to understand the potential impact of proposed actions on the ecosystem and wildlife species. Low quality information has been a major cause for litigation and economic loss. Since 1999, wind energy development has seen an exponential growth with unknown levels of impact onmore » wildlife species, in particular bird and bat species. The purpose of this article is to: (1) develop, validate, and apply a quantitative index to review avian/bat assessment quality for wind energy EIAs; and (2) assess the trends and status of avian/bat assessment quality in a sample of wind energy EIAs. This research presents the development and testing of the Avian and Bat Assessment Quality Index (ABAQI), a new approach to quantify information quality of ecological assessments within wind energy development EIAs in relation to avian and bat species based on review areas and factors derived from 23 state wind/wildlife siting guidance documents. The ABAQI was tested through a review of 49 publicly available EIA documents and validated by identifying high variation in avian and bat assessments quality for wind energy developments. Of all the reviewed EIAs, 66% failed to provide high levels of preconstruction avian and bat survey information, compared to recommended factors from state guidelines. This suggests the need for greater consistency from recommended guidelines by state, and mandatory compliance by EIA preparers to avoid possible habitat and species loss, wind energy development shut down, and future lawsuits. - Highlights: Black-Right-Pointing-Pointer We developed, validated, and applied a quantitative index to

  18. Image quality assessment metric for frame accumulated image

    NASA Astrophysics Data System (ADS)

    Yu, Jianping; Li, Gang; Wang, Shaohui; Lin, Ling

    2018-01-01

    The medical image quality determines the accuracy of diagnosis, and the gray-scale resolution is an important parameter to measure image quality. But current objective metrics are not very suitable for assessing medical images obtained by frame accumulation technology. Little attention was paid to the gray-scale resolution, basically based on spatial resolution and limited to the 256 level gray scale of the existing display device. Thus, this paper proposes a metric, "mean signal-to-noise ratio" (MSNR) based on signal-to-noise in order to be more reasonable to evaluate frame accumulated medical image quality. We demonstrate its potential application through a series of images under a constant illumination signal. Here, the mean image of enough images was regarded as the reference image. Several groups of images by different frame accumulation and their MSNR were calculated. The results of the experiment show that, compared with other quality assessment methods, the metric is simpler, more effective, and more suitable for assessing frame accumulated images that surpass the gray scale and precision of the original image.

  19. International drug price comparisons: quality assessment.

    PubMed

    Machado, Márcio; O'Brodovich, Ryan; Krahn, Murray; Einarson, Thomas R

    2011-01-01

    To quantitatively summarize results (i.e., prices and affordability) reported from international drug price comparison studies and assess their methodological quality. A systematic search of the most relevant databases-Medline, Embase, International Pharmaceutical Abstracts (IPA), and Scopus, from their inception to May 2009-was conducted to identify original research comparing international drug prices. International drug price information was extracted and recorded from accepted papers. Affordability was reported as drug prices adjusted for income. Study quality was assessed using six criteria: use of similar countries, use of a representative sample of drugs, selection of specific types of prices, identification of drug packaging, different weights on price indices, and the type of currency conversion used. Of the 1 828 studies identified, 21 were included. Only one study adequately addressed all quality issues. A large variation in study quality was observed due to the many methods used to conduct the drug price comparisons, such as different indices, economic parameters, price types, basket of drugs, and more. Thus, the quality of published studies was considered poor. Results varied across studies, but generally, higher income countries had higher drug prices. However, after adjusting drug prices for affordability, higher income countries had more affordable prices than lower income countries. Differences between drug prices and affordability in different countries were found. Low income countries reported less affordability of drugs, leaving room for potential problems with drug access, and consequently, a negative impact on health. The quality of the literature on this topic needs improvement.

  20. Assessing the quality of soil carbon using mid-infrared spectroscopy

    EPA Science Inventory

    With an increasing focus on carbon sequestration in soils to help offset anthropogenic greenhouse gas emissions, there is a growing need for standardized methods of assessing the quality (i.e., residence time) of soil organic carbon. Information on soil carbon quality is critica...

  1. Protein model quality assessment prediction by combining fragment comparisons and a consensus Cα contact potential

    PubMed Central

    Zhou, Hongyi; Skolnick, Jeffrey

    2009-01-01

    In this work, we develop a fully automated method for the quality assessment prediction of protein structural models generated by structure prediction approaches such as fold recognition servers, or ab initio methods. The approach is based on fragment comparisons and a consensus Cα contact potential derived from the set of models to be assessed and was tested on CASP7 server models. The average Pearson linear correlation coefficient between predicted quality and model GDT-score per target is 0.83 for the 98 targets which is better than those of other quality assessment methods that participated in CASP7. Our method also outperforms the other methods by about 3% as assessed by the total GDT-score of the selected top models. PMID:18004783

  2. The California stream quality assessment

    USGS Publications Warehouse

    Van Metre, Peter C.; Egler, Amanda L.; May, Jason T.

    2017-03-06

    In 2017, the U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) project is assessing stream quality in coastal California, United States. The USGS California Stream Quality Assessment (CSQA) will sample streams over most of the Central California Foothills and Coastal Mountains ecoregion (modified from Griffith and others, 2016), where rapid urban growth and intensive agriculture in the larger river valleys are raising concerns that stream health is being degraded. Findings will provide the public and policy-makers with information regarding which human and natural factors are the most critical in affecting stream quality and, thus, provide insights about possible approaches to protect the health of streams in the region.

  3. The adenosine triphosphate method as a quality control tool to assess 'cleanliness' of frequently touched hospital surfaces.

    PubMed

    Knape, L; Hambraeus, A; Lytsy, B

    2015-10-01

    The adenosine triphosphate (ATP) method is widely accepted as a quality control method to complement visual assessment, in the specifications of requirements, when purchasing cleaning contractors in Swedish hospitals. To examine whether the amount of biological load, as measured by ATP on frequently touched near-patient surfaces, had been reduced after an intervention; to evaluate the correlation between visual assessment and ATP levels on the same surfaces; to identify aspects of the performance of the ATP method as a tool in evaluating hospital cleanliness. A prospective intervention study in three phases was carried out in a medical ward and an intensive care unit (ICU) at a regional hospital in mid-Sweden between 2012 and 2013. Existing cleaning procedures were defined and baseline tests were sampled by visual inspection and ATP measurements of ten frequently touched surfaces in patients' rooms before and after intervention. The intervention consisted of educating nursing staff about the importance of hospital cleaning and direct feedback of ATP levels before and after cleaning. The mixed model showed a significant decrease in ATP levels after the intervention (P < 0.001). Relative light unit values were lower in the ICU. Cleanliness as judged by visual assessments improved. In the logistic regression analysis, there was a significant association between visual assessments and ATP levels. Direct feedback of ATP levels, together with education and introduction of written cleaning protocols, were effective tools to improve cleanliness. Visual assessment correlated with the level of ATP but the correlation was not absolute. The ATP method could serve as an educational tool for staff, but is not enough to assess hospital cleanliness in general as only a limited part of a large area is covered. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  4. Application of biomonitoring and support vector machine in water quality assessment*

    PubMed Central

    Liao, Yue; Xu, Jian-yu; Wang, Zhu-wei

    2012-01-01

    The behavior of schools of zebrafish (Danio rerio) was studied in acute toxicity environments. Behavioral features were extracted and a method for water quality assessment using support vector machine (SVM) was developed. The behavioral parameters of fish were recorded and analyzed during one hour in an environment of a 24-h half-lethal concentration (LC50) of a pollutant. The data were used to develop a method to evaluate water quality, so as to give an early indication of toxicity. Four kinds of metal ions (Cu2+, Hg2+, Cr6+, and Cd2+) were used for toxicity testing. To enhance the efficiency and accuracy of assessment, a method combining SVM and a genetic algorithm (GA) was used. The results showed that the average prediction accuracy of the method was over 80% and the time cost was acceptable. The method gave satisfactory results for a variety of metal pollutants, demonstrating that this is an effective approach to the classification of water quality. PMID:22467374

  5. A Methodology for Anatomic Ultrasound Image Diagnostic Quality Assessment.

    PubMed

    Hemmsen, Martin Christian; Lange, Theis; Brandt, Andreas Hjelm; Nielsen, Michael Bachmann; Jensen, Jorgen Arendt

    2017-01-01

    This paper discusses the methods for the assessment of ultrasound image quality based on our experiences with evaluating new methods for anatomic imaging. It presents a methodology to ensure a fair assessment between competing imaging methods using clinically relevant evaluations. The methodology is valuable in the continuing process of method optimization and guided development of new imaging methods. It includes a three phased study plan covering from initial prototype development to clinical assessment. Recommendations to the clinical assessment protocol, software, and statistical analysis are presented. Earlier uses of the methodology has shown that it ensures validity of the assessment, as it separates the influences between developer, investigator, and assessor once a research protocol has been established. This separation reduces confounding influences on the result from the developer to properly reveal the clinical value. This paper exemplifies the methodology using recent studies of synthetic aperture sequential beamforming tissue harmonic imaging.

  6. A historical review of the methods of determination of soil properties for soil quality and land degradation assessment

    NASA Astrophysics Data System (ADS)

    Pulido, Manuel; Schnabel, Susanne; Francisco Lavado Contador, Joaquín; Gómez-Gutiérrez, Álvaro; Miralles, Isabel; Lozano-Parra, Javier; Antoneli, Valdemir; Brevik, Eric C.; Cerdà, Artemi

    2017-04-01

    Properly assessing soil quality and land degradation is one of the main concerns of soil scientists in recent decades. Nowadays there are several available assessment systems based mainly on indicators, i.e. on soil-related parameters, that allow one to determine the current state of natural soils at different scales. These systems vary depending on ecosystem type and soil function studied as well as the accuracy of the methods (techniques and tools) historically used in the determination of several soil parameters. In this study, we show a historical review of many methods of determining soil properties used regularly as soil quality and land degradation indicators. We have considered 5 worldwide historical periods: [1] The pioneers: before 1889, [2] USDA impulse: 1889 - 1945, [3] Productivity paradigm: 1946 - 1972, [4] Conservationist paradigm: 1973 - 2001, and [5] Current methodologies: 2002 - present. The limits of each period have been determined according to some key milestones, for humanity in general and soil science in particular, such as the creation of the United States Department of Agriculture (USDA) in 1889, the end of World War II in 1945 or the publication of relevant works such as The limits to growth in 1972. The development of the Soil Management Assessment Framework (SMAF) indexing tool by American soil scientists in 2001 marks a turning point from which new methodologies and paradigms began to be dominant among methods of determination. Finally, the methods historically used to determine more than 100 soil properties have been reviewed by consulting around 1,500 references published between 1305 and 2017. Approximately 10% of the references were key works to contextualize the first two historical periods, i.e. before 1945, and almost half of all references were published in the second half of the twentieth century (1946 - 2001). A logical tendency in gaining progressively accuracy in methods has been observed as well as a major boom in the

  7. [Certification assessment and quality and risk management].

    PubMed

    Papin-Morardet, Maud

    2018-03-01

    Organised by the French National Health Authority (HAS), certification is an external assessment process which is obligatory for all public and private health facilities, whatever their size or activity. The aim is to independently evaluate the quality of the health care provision of hospitals and clinics in France. This article looks at the investigation methods and the procedure used during the certification assessment of Henri Mondor University Hospitals in 2016. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  8. Rational Selection, Criticality Assessment, and Tiering of Quality Attributes and Test Methods for Analytical Similarity Evaluation of Biosimilars.

    PubMed

    Vandekerckhove, Kristof; Seidl, Andreas; Gutka, Hiten; Kumar, Manish; Gratzl, Gyöngyi; Keire, David; Coffey, Todd; Kuehne, Henriette

    2018-05-10

    Leading regulatory agencies recommend biosimilar assessment to proceed in a stepwise fashion, starting with a detailed analytical comparison of the structural and functional properties of the proposed biosimilar and reference product. The degree of analytical similarity determines the degree of residual uncertainty that must be addressed through downstream in vivo studies. Substantive evidence of similarity from comprehensive analytical testing may justify a targeted clinical development plan, and thus enable a shorter path to licensing. The importance of a careful design of the analytical similarity study program therefore should not be underestimated. Designing a state-of-the-art analytical similarity study meeting current regulatory requirements in regions such as the USA and EU requires a methodical approach, consisting of specific steps that far precede the work on the actual analytical study protocol. This white paper discusses scientific and methodological considerations on the process of attribute and test method selection, criticality assessment, and subsequent assignment of analytical measures to US FDA's three tiers of analytical similarity assessment. Case examples of selection of critical quality attributes and analytical methods for similarity exercises are provided to illustrate the practical implementation of the principles discussed.

  9. Methods for the analysis of ordinal response data in medical image quality assessment.

    PubMed

    Keeble, Claire; Baxter, Paul D; Gislason-Lee, Amber J; Treadgold, Laura A; Davies, Andrew G

    2016-07-01

    The assessment of image quality in medical imaging often requires observers to rate images for some metric or detectability task. These subjective results are used in optimization, radiation dose reduction or system comparison studies and may be compared to objective measures from a computer vision algorithm performing the same task. One popular scoring approach is to use a Likert scale, then assign consecutive numbers to the categories. The mean of these response values is then taken and used for comparison with the objective or second subjective response. Agreement is often assessed using correlation coefficients. We highlight a number of weaknesses in this common approach, including inappropriate analyses of ordinal data and the inability to properly account for correlations caused by repeated images or observers. We suggest alternative data collection and analysis techniques such as amendments to the scale and multilevel proportional odds models. We detail the suitability of each approach depending upon the data structure and demonstrate each method using a medical imaging example. Whilst others have raised some of these issues, we evaluated the entire study from data collection to analysis, suggested sources for software and further reading, and provided a checklist plus flowchart for use with any ordinal data. We hope that raised awareness of the limitations of the current approaches will encourage greater method consideration and the utilization of a more appropriate analysis. More accurate comparisons between measures in medical imaging will lead to a more robust contribution to the imaging literature and ultimately improved patient care.

  10. Automatic assessment of voice quality according to the GRBAS scale.

    PubMed

    Sáenz-Lechón, Nicolás; Godino-Llorente, Juan I; Osma-Ruiz, Víctor; Blanco-Velasco, Manuel; Cruz-Roldán, Fernando

    2006-01-01

    Nowadays, the most extended techniques to measure the voice quality are based on perceptual evaluation by well trained professionals. The GRBAS scale is a widely used method for perceptual evaluation of voice quality. The GRBAS scale is widely used in Japan and there is increasing interest in both Europe and the United States. However, this technique needs well-trained experts, and is based on the evaluator's expertise, depending a lot on his own psycho-physical state. Furthermore, a great variability in the assessments performed from one evaluator to another is observed. Therefore, an objective method to provide such measurement of voice quality would be very valuable. In this paper, the automatic assessment of voice quality is addressed by means of short-term Mel cepstral parameters (MFCC), and learning vector quantization (LVQ) in a pattern recognition stage. Results show that this approach provides acceptable results for this purpose, with accuracy around 65% at the best.

  11. Low-cost oblique illumination: an image quality assessment.

    PubMed

    Ruiz-Santaquiteria, Jesus; Espinosa-Aranda, Jose Luis; Deniz, Oscar; Sanchez, Carlos; Borrego-Ramos, Maria; Blanco, Saul; Cristobal, Gabriel; Bueno, Gloria

    2018-01-01

    We study the effectiveness of several low-cost oblique illumination filters to improve overall image quality, in comparison with standard bright field imaging. For this purpose, a dataset composed of 3360 diatom images belonging to 21 taxa was acquired. Subjective and objective image quality assessments were done. The subjective evaluation was performed by a group of diatom experts by psychophysical test where resolution, focus, and contrast were assessed. Moreover, some objective nonreference image quality metrics were applied to the same image dataset to complete the study, together with the calculation of several texture features to analyze the effect of these filters in terms of textural properties. Both image quality evaluation methods, subjective and objective, showed better results for images acquired using these illumination filters in comparison with the no filtered image. These promising results confirm that this kind of illumination filters can be a practical way to improve the image quality, thanks to the simple and low cost of the design and manufacturing process. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  12. Designing and evaluating the MULTICOM protein local and global model quality prediction methods in the CASP10 experiment

    PubMed Central

    2014-01-01

    Background Protein model quality assessment is an essential component of generating and using protein structural models. During the Tenth Critical Assessment of Techniques for Protein Structure Prediction (CASP10), we developed and tested four automated methods (MULTICOM-REFINE, MULTICOM-CLUSTER, MULTICOM-NOVEL, and MULTICOM-CONSTRUCT) that predicted both local and global quality of protein structural models. Results MULTICOM-REFINE was a clustering approach that used the average pairwise structural similarity between models to measure the global quality and the average Euclidean distance between a model and several top ranked models to measure the local quality. MULTICOM-CLUSTER and MULTICOM-NOVEL were two new support vector machine-based methods of predicting both the local and global quality of a single protein model. MULTICOM-CONSTRUCT was a new weighted pairwise model comparison (clustering) method that used the weighted average similarity between models in a pool to measure the global model quality. Our experiments showed that the pairwise model assessment methods worked better when a large portion of models in the pool were of good quality, whereas single-model quality assessment methods performed better on some hard targets when only a small portion of models in the pool were of reasonable quality. Conclusions Since digging out a few good models from a large pool of low-quality models is a major challenge in protein structure prediction, single model quality assessment methods appear to be poised to make important contributions to protein structure modeling. The other interesting finding was that single-model quality assessment scores could be used to weight the models by the consensus pairwise model comparison method to improve its accuracy. PMID:24731387

  13. Designing and evaluating the MULTICOM protein local and global model quality prediction methods in the CASP10 experiment.

    PubMed

    Cao, Renzhi; Wang, Zheng; Cheng, Jianlin

    2014-04-15

    Protein model quality assessment is an essential component of generating and using protein structural models. During the Tenth Critical Assessment of Techniques for Protein Structure Prediction (CASP10), we developed and tested four automated methods (MULTICOM-REFINE, MULTICOM-CLUSTER, MULTICOM-NOVEL, and MULTICOM-CONSTRUCT) that predicted both local and global quality of protein structural models. MULTICOM-REFINE was a clustering approach that used the average pairwise structural similarity between models to measure the global quality and the average Euclidean distance between a model and several top ranked models to measure the local quality. MULTICOM-CLUSTER and MULTICOM-NOVEL were two new support vector machine-based methods of predicting both the local and global quality of a single protein model. MULTICOM-CONSTRUCT was a new weighted pairwise model comparison (clustering) method that used the weighted average similarity between models in a pool to measure the global model quality. Our experiments showed that the pairwise model assessment methods worked better when a large portion of models in the pool were of good quality, whereas single-model quality assessment methods performed better on some hard targets when only a small portion of models in the pool were of reasonable quality. Since digging out a few good models from a large pool of low-quality models is a major challenge in protein structure prediction, single model quality assessment methods appear to be poised to make important contributions to protein structure modeling. The other interesting finding was that single-model quality assessment scores could be used to weight the models by the consensus pairwise model comparison method to improve its accuracy.

  14. A framework for assessing Health Economic Evaluation (HEE) quality appraisal instruments

    PubMed Central

    2012-01-01

    Background Health economic evaluations support the health care decision-making process by providing information on costs and consequences of health interventions. The quality of such studies is assessed by health economic evaluation (HEE) quality appraisal instruments. At present, there is no instrument for measuring and improving the quality of such HEE quality appraisal instruments. Therefore, the objectives of this study are to establish a framework for assessing the quality of HEE quality appraisal instruments to support and improve their quality, and to apply this framework to those HEE quality appraisal instruments which have been subject to more scrutiny than others, in order to test the framework and to demonstrate the shortcomings of existing HEE quality appraisal instruments. Methods To develop the quality assessment framework for HEE quality appraisal instruments, the experiences of using appraisal tools for clinical guidelines are used. Based on a deductive iterative process, clinical guideline appraisal instruments identified through literature search are reviewed, consolidated, and adapted to produce the final quality assessment framework for HEE quality appraisal instruments. Results The final quality assessment framework for HEE quality appraisal instruments consists of 36 items organized within 7 dimensions, each of which captures a specific domain of quality. Applying the quality assessment framework to four existing HEE quality appraisal instruments, it is found that these four quality appraisal instruments are of variable quality. Conclusions The framework described in this study should be regarded as a starting point for appraising the quality of HEE quality appraisal instruments. This framework can be used by HEE quality appraisal instrument producers to support and improve the quality and acceptance of existing and future HEE quality appraisal instruments. By applying this framework, users of HEE quality appraisal instruments can become aware

  15. Higher Education Quality Assessment Model: Towards Achieving Educational Quality Standard

    ERIC Educational Resources Information Center

    Noaman, Amin Y.; Ragab, Abdul Hamid M.; Madbouly, Ayman I.; Khedra, Ahmed M.; Fayoumi, Ayman G.

    2017-01-01

    This paper presents a developed higher education quality assessment model (HEQAM) that can be applied for enhancement of university services. This is because there is no universal unified quality standard model that can be used to assess the quality criteria of higher education institutes. The analytical hierarchy process is used to identify the…

  16. Quality Assessment of TPB-Based Questionnaires: A Systematic Review

    PubMed Central

    Oluka, Obiageli Crystal; Nie, Shaofa; Sun, Yi

    2014-01-01

    Objective This review is aimed at assessing the quality of questionnaires and their development process based on the theory of planned behavior (TPB) change model. Methods A systematic literature search for studies with the primary aim of TPB-based questionnaire development was conducted in relevant databases between 2002 and 2012 using selected search terms. Ten of 1,034 screened abstracts met the inclusion criteria and were assessed for methodological quality using two different appraisal tools: one for the overall methodological quality of each study and the other developed for the appraisal of the questionnaire content and development process. Both appraisal tools consisted of items regarding the likelihood of bias in each study and were eventually combined to give the overall quality score for each included study. Results 8 of the 10 included studies showed low risk of bias in the overall quality assessment of each study, while 9 of the studies were of high quality based on the quality appraisal of questionnaire content and development process. Conclusion Quality appraisal of the questionnaires in the 10 reviewed studies was successfully conducted, highlighting the top problem areas (including: sample size estimation; inclusion of direct and indirect measures; and inclusion of questions on demographics) in the development of TPB-based questionnaires and the need for researchers to provide a more detailed account of their development process. PMID:24722323

  17. Identification of the hydrogeochemical processes and assessment of groundwater quality using classic integrated geochemical methods in the Southeastern part of Ordos basin, China.

    PubMed

    Yang, Qingchun; Li, Zijun; Ma, Hongyun; Wang, Luchen; Martín, Jordi Delgado

    2016-11-01

    Insufficient understanding of the hydrogeochemistry of aquifers makes it necessary to conduct a preliminary water quality assessment in the southern region of Ordos Basin, an arid area in the world. In this paper, the major ions of groundwater have been studied aiming at evaluating the hydrogeochemical processes that probably affect the groundwater quality using 150 samples collected in 2015. The two prevalent hydrochemical facies, HCO 3 Mg·Na·Ca and HCO 3 Mg·Ca·Na type water, have been identified based on the hydrochemical analysis from Piper trilinear diagram. Compositional relations have been used to assess the origin of solutes and confirm the predominant hydrogeochemical processes responsible for the various ions in the groundwater. The results show that the ions are derived from leaching effect, evaporation and condensation, cation exchange, mixing effect and human activities. Finally groundwater quality was assessed with single factor and set pair methods, the results indicate that groundwater quality in the study region is generally poor in terms of standard of national groundwater quality. The results obtained in this study will be useful to understand the groundwater quality status for effective management and utilization of the groundwater resource. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Softcopy quality ruler method: implementation and validation

    NASA Astrophysics Data System (ADS)

    Jin, Elaine W.; Keelan, Brian W.; Chen, Junqing; Phillips, Jonathan B.; Chen, Ying

    2009-01-01

    A softcopy quality ruler method was implemented for the International Imaging Industry Association (I3A) Camera Phone Image Quality (CPIQ) Initiative. This work extends ISO 20462 Part 3 by virtue of creating reference digital images of known subjective image quality, complimenting the hardcopy Standard Reference Stimuli (SRS). The softcopy ruler method was developed using images from a Canon EOS 1Ds Mark II D-SLR digital still camera (DSC) and a Kodak P880 point-and-shoot DSC. Images were viewed on an Apple 30in Cinema Display at a viewing distance of 34 inches. Ruler images were made for 16 scenes. Thirty ruler images were generated for each scene, representing ISO 20462 Standard Quality Scale (SQS) values of approximately 2 to 31 at an increment of one just noticeable difference (JND) by adjusting the system modulation transfer function (MTF). A Matlab GUI was developed to display the ruler and test images side-by-side with a user-adjustable ruler level controlled by a slider. A validation study was performed at Kodak, Vista Point Technology, and Aptina Imaging in which all three companies set up a similar viewing lab to run the softcopy ruler method. The results show that the three sets of data are in reasonable agreement with each other, with the differences within the range expected from observer variability. Compared to previous implementations of the quality ruler, the slider-based user interface allows approximately 2x faster assessments with 21.6% better precision.

  19. The integrated quality assessment of Chinese commercial dry red wine based on a method of online HPLC-DAD-CL combined with HPLC-ESI-MS.

    PubMed

    Yu, Hai-Xiang; Sun, Li-Qiong; Qi, Jin

    2014-07-01

    To apply an integrated quality assessment strategy to investigate the quality of multiple Chinese commercial dry red wine samples. A comprehensive method was developed by combining a high performance liquid chromatography-diode array detector-chemiluminescence (HPLC-DAD-CL) online hyphenated system with an HPLC-ESI-MS technique. Chromatographic and H2O2-scavenging active fingerprints of thirteen batches of different, commercially available Chinese dry red wine samples were obtained and analyzed. Twenty-five compounds, including eighteen antioxidants were identified and evaluated. The dominant and characteristic antioxidants in the samples were identified. The relationships between antioxidant potency and the cultivated variety of grape, producing area, cellaring period, and trade mark are also discussed. The results provide the feasibility for an integrated quality assessment strategy to be efficiently and objectively used in quality (especially antioxidant activity) assessment and identification of dry red wine. Copyright © 2014 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  20. A systematic literature review of open source software quality assessment models.

    PubMed

    Adewumi, Adewole; Misra, Sanjay; Omoregbe, Nicholas; Crawford, Broderick; Soto, Ricardo

    2016-01-01

    Many open source software (OSS) quality assessment models are proposed and available in the literature. However, there is little or no adoption of these models in practice. In order to guide the formulation of newer models so they can be acceptable by practitioners, there is need for clear discrimination of the existing models based on their specific properties. Based on this, the aim of this study is to perform a systematic literature review to investigate the properties of the existing OSS quality assessment models by classifying them with respect to their quality characteristics, the methodology they use for assessment, and their domain of application so as to guide the formulation and development of newer models. Searches in IEEE Xplore, ACM, Science Direct, Springer and Google Search is performed so as to retrieve all relevant primary studies in this regard. Journal and conference papers between the year 2003 and 2015 were considered since the first known OSS quality model emerged in 2003. A total of 19 OSS quality assessment model papers were selected. To select these models we have developed assessment criteria to evaluate the quality of the existing studies. Quality assessment models are classified into five categories based on the quality characteristics they possess namely: single-attribute, rounded category, community-only attribute, non-community attribute as well as the non-quality in use models. Our study reflects that software selection based on hierarchical structures is found to be the most popular selection method in the existing OSS quality assessment models. Furthermore, we found that majority (47%) of the existing models do not specify any domain of application. In conclusion, our study will be a valuable contribution to the community and helps the quality assessment model developers in formulating newer models and also to the practitioners (software evaluators) in selecting suitable OSS in the midst of alternatives.

  1. The comparison of rapid bioassays for the assessment of urban groundwater quality.

    PubMed

    Dewhurst, R E; Wheeler, J R; Chummun, K S; Mather, J D; Callaghan, A; Crane, M

    2002-05-01

    Groundwater is a complex mixture of chemicals that is naturally variable. Current legislation in the UK requires that groundwater quality and the degree of contamination are assessed using chemical methods. Such methods do not consider the synergistic or antagonistic interactions that may affect the bioavailability and toxicity of pollutants in the environment. Bioassays are a method for assessing the toxic impact of whole groundwater samples on the environment. Three rapid bioassays, Eclox, Microtox and ToxAlert, and a Daphnia magna 48-h immobilisation test were used to assess groundwater quality from sites with a wide range of historical uses. Eclox responses indicated that the test was very sensitive to changes in groundwater chemistry; 77% of the results had a percentage inhibition greater than 90%. ToxAlert, although suitable for monitoring changes in water quality under laboratory conditions, produced highly variable results due to fluctuations in temperature and the chemical composition of the samples. Microtox produced replicable results that correlated with those from D. magna tests.

  2. Methods of Quality Appraisal for Studies Reviewed by Evidence Clearinghouses

    ERIC Educational Resources Information Center

    Wilson, Sandra Jo; Tanner-Smith, Emily

    2015-01-01

    This presentation will discuss quality appraisal methods for assessing research studies used in systematic reviews, research syntheses, and evidence-based practice repositories such as the What Works Clearinghouse. The different ways that the methodological rigor and risk of bias of primary studies included in syntheses is assessed means that…

  3. A novel, fuzzy-based air quality index (FAQI) for air quality assessment

    NASA Astrophysics Data System (ADS)

    Sowlat, Mohammad Hossein; Gharibi, Hamed; Yunesian, Masud; Tayefeh Mahmoudi, Maryam; Lotfi, Saeedeh

    2011-04-01

    The ever increasing level of air pollution in most areas of the world has led to development of a variety of air quality indices for estimation of health effects of air pollution, though the indices have their own limitations such as high levels of subjectivity. Present study, therefore, aimed at developing a novel, fuzzy-based air quality index (FAQI ) to handle such limitations. The index developed by present study is based on fuzzy logic that is considered as one of the most common computational methods of artificial intelligence. In addition to criteria air pollutants (i.e. CO, SO 2, PM 10, O 3, NO 2), benzene, toluene, ethylbenzene, xylene, and 1,3-butadiene were also taken into account in the index proposed, because of their considerable health effects. Different weighting factors were then assigned to each pollutant according to its priority. Trapezoidal membership functions were employed for classifications and the final index consisted of 72 inference rules. To assess the performance of the index, a case study was carried out employing air quality data at five different sampling stations in Tehran, Iran, from January 2008 to December 2009, results of which were then compared to the results obtained from USEPA air quality index (AQI). According to the results from present study, fuzzy-based air quality index is a comprehensive tool for classification of air quality and tends to produce accurate results. Therefore, it can be considered useful, reliable, and suitable for consideration by local authorities in air quality assessment and management schemes. Fuzzy-based air quality index (FAQI).

  4. Learning to rank for blind image quality assessment.

    PubMed

    Gao, Fei; Tao, Dacheng; Gao, Xinbo; Li, Xuelong

    2015-10-01

    Blind image quality assessment (BIQA) aims to predict perceptual image quality scores without access to reference images. State-of-the-art BIQA methods typically require subjects to score a large number of images to train a robust model. However, subjective quality scores are imprecise, biased, and inconsistent, and it is challenging to obtain a large-scale database, or to extend existing databases, because of the inconvenience of collecting images, training the subjects, conducting subjective experiments, and realigning human quality evaluations. To combat these limitations, this paper explores and exploits preference image pairs (PIPs) such as the quality of image Ia is better than that of image Ib for training a robust BIQA model. The preference label, representing the relative quality of two images, is generally precise and consistent, and is not sensitive to image content, distortion type, or subject identity; such PIPs can be generated at a very low cost. The proposed BIQA method is one of learning to rank. We first formulate the problem of learning the mapping from the image features to the preference label as one of classification. In particular, we investigate the utilization of a multiple kernel learning algorithm based on group lasso to provide a solution. A simple but effective strategy to estimate perceptual image quality scores is then presented. Experiments show that the proposed BIQA method is highly effective and achieves a performance comparable with that of state-of-the-art BIQA algorithms. Moreover, the proposed method can be easily extended to new distortion categories.

  5. Adult orthodontics: a quality assessment of Internet information.

    PubMed

    McMorrow, Siobhán Mary; Millett, Declan T

    2016-09-01

    This study evaluated the quality, reliability and readability of information on the Internet on adult orthodontics. A quality assessment of adult orthodontic websites. Postgraduate Orthodontic Unit, Cork University Dental School and Hospital, Cork, Ireland. An Internet search using three search engines (Google, Yahoo and Bing) was conducted using the terms ('adult orthodontics' and 'adult braces'). The first 50 websites from each engine and under each search term were screened and exclusion criteria applied. Included websites were then assessed for quality using four methods: the HON seal, JAMA benchmarks, the DISCERN instrument and the LIDA tool. Readability of included websites was assessed using the Flesch Reading Ease Score (FRES). Only 13 websites met the inclusion criteria. Most were of US origin (n = 8; 61%). The authors of the websites were dentists (n = 5; 39%), professional organizations (n = 2; 15%), past patients (n = 2; 15%) and unspecified (n = 4; 31%). Only 1 website displayed the HON seal and three websites contained all JAMA benchmarks. The mean overall score for DISCERN was 3.9/5 and the mean total LIDA score was 115/144. The average FRES score was 63.1/100. The number of informative websites on adult orthodontics is low and these are of moderate quality. More accurate, high-quality Internet resources are required on adult orthodontics. Recommendations are made as to how this may be achieved.

  6. Retinal image quality assessment based on image clarity and content

    NASA Astrophysics Data System (ADS)

    Abdel-Hamid, Lamiaa; El-Rafei, Ahmed; El-Ramly, Salwa; Michelson, Georg; Hornegger, Joachim

    2016-09-01

    Retinal image quality assessment (RIQA) is an essential step in automated screening systems to avoid misdiagnosis caused by processing poor quality retinal images. A no-reference transform-based RIQA algorithm is introduced that assesses images based on five clarity and content quality issues: sharpness, illumination, homogeneity, field definition, and content. Transform-based RIQA algorithms have the advantage of considering retinal structures while being computationally inexpensive. Wavelet-based features are proposed to evaluate the sharpness and overall illumination of the images. A retinal saturation channel is designed and used along with wavelet-based features for homogeneity assessment. The presented sharpness and illumination features are utilized to assure adequate field definition, whereas color information is used to exclude nonretinal images. Several publicly available datasets of varying quality grades are utilized to evaluate the feature sets resulting in area under the receiver operating characteristic curve above 0.99 for each of the individual feature sets. The overall quality is assessed by a classifier that uses the collective features as an input vector. The classification results show superior performance of the algorithm in comparison to other methods from literature. Moreover, the algorithm addresses efficiently and comprehensively various quality issues and is suitable for automatic screening systems.

  7. Using Data Mining for Wine Quality Assessment

    NASA Astrophysics Data System (ADS)

    Cortez, Paulo; Teixeira, Juliana; Cerdeira, António; Almeida, Fernando; Matos, Telmo; Reis, José

    Certification and quality assessment are crucial issues within the wine industry. Currently, wine quality is mostly assessed by physicochemical (e.g alcohol levels) and sensory (e.g. human expert evaluation) tests. In this paper, we propose a data mining approach to predict wine preferences that is based on easily available analytical tests at the certification step. A large dataset is considered with white vinho verde samples from the Minho region of Portugal. Wine quality is modeled under a regression approach, which preserves the order of the grades. Explanatory knowledge is given in terms of a sensitivity analysis, which measures the response changes when a given input variable is varied through its domain. Three regression techniques were applied, under a computationally efficient procedure that performs simultaneous variable and model selection and that is guided by the sensitivity analysis. The support vector machine achieved promising results, outperforming the multiple regression and neural network methods. Such model is useful for understanding how physicochemical tests affect the sensory preferences. Moreover, it can support the wine expert evaluations and ultimately improve the production.

  8. 42 CFR 460.140 - Additional quality assessment activities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Additional quality assessment activities. 460.140... FOR THE ELDERLY (PACE) Quality Assessment and Performance Improvement § 460.140 Additional quality assessment activities. A PACE organization must meet external quality assessment and reporting requirements...

  9. Objective measures for quality assessment of automatic skin enhancement algorithms

    NASA Astrophysics Data System (ADS)

    Ciuc, Mihai; Capata, Adrian; Florea, Corneliu

    2010-01-01

    Automatic portrait enhancement by attenuating skin flaws (pimples, blemishes, wrinkles, etc.) has received considerable attention from digital camera manufacturers thanks to its impact on the public. Subsequently, a number of algorithms have been developed to meet this need. One central aspect to developing such an algorithm is quality assessment: having a few numbers that precisely indicate the amount of beautification brought by an algorithm (as perceived by human observers) is of great help, as it works on circumvent time-costly human evaluation. In this paper, we propose a method to numerically evaluate the quality of a skin beautification algorithm. The most important aspects we take into account and quantize to numbers are the quality of the skin detector, the amount of smoothing performed by the method, the preservation of intrinsic skin texture, and the preservation of facial features. We combine these measures into two numbers that assess the quality of skin detection and beautification. The derived measures are highly correlated with human perception, therefore they constitute a helpful tool for tuning and comparing algorithms.

  10. Web Service for Positional Quality Assessment: the Wps Tier

    NASA Astrophysics Data System (ADS)

    Xavier, E. M. A.; Ariza-López, F. J.; Ureña-Cámara, M. A.

    2015-08-01

    In the field of spatial data every day we have more and more information available, but we still have little or very little information about the quality of spatial data. We consider that the automation of the spatial data quality assessment is a true need for the geomatic sector, and that automation is possible by means of web processing services (WPS), and the application of specific assessment procedures. In this paper we propose and develop a WPS tier centered on the automation of the positional quality assessment. An experiment using the NSSDA positional accuracy method is presented. The experiment involves the uploading by the client of two datasets (reference and evaluation data). The processing is to determine homologous pairs of points (by distance) and calculate the value of positional accuracy under the NSSDA standard. The process generates a small report that is sent to the client. From our experiment, we reached some conclusions on the advantages and disadvantages of WPSs when applied to the automation of spatial data accuracy assessments.

  11. Video quality assessment using motion-compensated temporal filtering and manifold feature similarity

    PubMed Central

    Yu, Mei; Jiang, Gangyi; Shao, Feng; Peng, Zongju

    2017-01-01

    Well-performed Video quality assessment (VQA) method should be consistent with human visual systems for better prediction accuracy. In this paper, we propose a VQA method using motion-compensated temporal filtering (MCTF) and manifold feature similarity. To be more specific, a group of frames (GoF) is first decomposed into a temporal high-pass component (HPC) and a temporal low-pass component (LPC) by MCTF. Following this, manifold feature learning (MFL) and phase congruency (PC) are used to predict the quality of temporal LPC and temporal HPC respectively. The quality measures of the LPC and the HPC are then combined as GoF quality. A temporal pooling strategy is subsequently used to integrate GoF qualities into an overall video quality. The proposed VQA method appropriately processes temporal information in video by MCTF and temporal pooling strategy, and simulate human visual perception by MFL. Experiments on publicly available video quality database showed that in comparison with several state-of-the-art VQA methods, the proposed VQA method achieves better consistency with subjective video quality and can predict video quality more accurately. PMID:28445489

  12. Subjective Quality Assessment of Underwater Video for Scientific Applications.

    PubMed

    Moreno-Roldán, José-Miguel; Luque-Nieto, Miguel-Ángel; Poncela, Javier; Díaz-del-Río, Víctor; Otero, Pablo

    2015-12-15

    Underwater video services could be a key application in the better scientific knowledge of the vast oceanic resources in our planet. However, limitations in the capacity of current available technology for underwater networks (UWSNs) raise the question of the feasibility of these services. When transmitting video, the main constraints are the limited bandwidth and the high propagation delays. At the same time the service performance depends on the needs of the target group. This paper considers the problems of estimations for the Mean Opinion Score (a standard quality measure) in UWSNs based on objective methods and addresses the topic of quality assessment in potential underwater video services from a subjective point of view. The experimental design and the results of a test planned according standardized psychometric methods are presented. The subjects used in the quality assessment test were ocean scientists. Video sequences were recorded in actual exploration expeditions and were processed to simulate conditions similar to those that might be found in UWSNs. Our experimental results show how videos are considered to be useful for scientific purposes even in very low bitrate conditions.

  13. Translation Quality Assessment in Health Research: A Functionalist Alternative to Back-Translation.

    PubMed

    Colina, Sonia; Marrone, Nicole; Ingram, Maia; Sánchez, Daisey

    2017-09-01

    As international research studies become more commonplace, the importance of developing multilingual research instruments continues to increase and with it that of translated materials. It is therefore not unexpected that assessing the quality of translated materials (e.g., research instruments, questionnaires, etc.) has become essential to cross-cultural research, given that the reliability and validity of the research findings crucially depend on the translated instruments. In some fields (e.g., public health and medicine), the quality of translated instruments can also impact the effectiveness and success of interventions and public campaigns. Back-translation (BT) is a commonly used quality assessment tool in cross-cultural research. This quality assurance technique consists of (a) translation (target text [TT 1 ]) of the source text (ST), (b) translation (TT 2 ) of TT 1 back into the source language, and (c) comparison of TT 2 with ST to make sure there are no discrepancies. The accuracy of the BT with respect to the source is supposed to reflect equivalence/accuracy of the TT. This article shows how the use of BT as a translation quality assessment method can have a detrimental effect on a research study and proposes alternatives to BT. One alternative is illustrated on the basis of the translation and quality assessment methods used in a research study on hearing loss carried out in a border community in the southwest of the United States.

  14. Assessing Regional Emissions Reductions from Travel Efficiency: Applying the Travel Efficiency Assessment Method

    EPA Pesticide Factsheets

    This presentation from the 2016 TRB Summer Conference on Transportation Planning and Air Quality summarizes the application of the Travel Efficiency Assessment Method (TEAM) which analyzed selected transportation emission reduction strategies in three case

  15. VoroMQA: Assessment of protein structure quality using interatomic contact areas.

    PubMed

    Olechnovič, Kliment; Venclovas, Česlovas

    2017-06-01

    In the absence of experimentally determined protein structure many biological questions can be addressed using computational structural models. However, the utility of protein structural models depends on their quality. Therefore, the estimation of the quality of predicted structures is an important problem. One of the approaches to this problem is the use of knowledge-based statistical potentials. Such methods typically rely on the statistics of distances and angles of residue-residue or atom-atom interactions collected from experimentally determined structures. Here, we present VoroMQA (Voronoi tessellation-based Model Quality Assessment), a new method for the estimation of protein structure quality. Our method combines the idea of statistical potentials with the use of interatomic contact areas instead of distances. Contact areas, derived using Voronoi tessellation of protein structure, are used to describe and seamlessly integrate both explicit interactions between protein atoms and implicit interactions of protein atoms with solvent. VoroMQA produces scores at atomic, residue, and global levels, all in the fixed range from 0 to 1. The method was tested on the CASP data and compared to several other single-model quality assessment methods. VoroMQA showed strong performance in the recognition of the native structure and in the structural model selection tests, thus demonstrating the efficacy of interatomic contact areas in estimating protein structure quality. The software implementation of VoroMQA is freely available as a standalone application and as a web server at http://bioinformatics.lt/software/voromqa. Proteins 2017; 85:1131-1145. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  16. How Can We Best Assess the Quality of Life of People with Dementia? The Bath Assessment of Subjective Quality of Life in Dementia (BASQID)

    ERIC Educational Resources Information Center

    Trigg, Richard; Skevington, Suzanne M.; Jones, Roy W.

    2007-01-01

    Purpose: The study aim was to develop a measure of self-reported quality of life (QoL) for people with mild to moderate dementia based on their views--the Bath Assessment of Subjective Quality of Life in Dementia (BASQID). Design and Methods: We developed the measure through multiple stages. Two field tests of the measure (ns = 60 and 150)…

  17. Quality assessment of color images based on the measure of just noticeable color difference

    NASA Astrophysics Data System (ADS)

    Chou, Chun-Hsien; Hsu, Yun-Hsiang

    2014-01-01

    Accurate assessment on the quality of color images is an important step to many image processing systems that convey visual information of the reproduced images. An accurate objective image quality assessment (IQA) method is expected to give the assessment result highly agreeing with the subjective assessment. To assess the quality of color images, many approaches simply apply the metric for assessing the quality of gray scale images to each of three color channels of the color image, neglecting the correlation among three color channels. In this paper, a metric for assessing color images' quality is proposed, in which the model of variable just-noticeable color difference (VJNCD) is employed to estimate the visibility thresholds of distortion inherent in each color pixel. With the estimated visibility thresholds of distortion, the proposed metric measures the average perceptible distortion in terms of the quantized distortion according to the perceptual error map similar to that defined by National Bureau of Standards (NBS) for converting the color difference enumerated by CIEDE2000 to the objective score of perceptual quality assessment. The perceptual error map in this case is designed for each pixel according to the visibility threshold estimated by the VJNCD model. The performance of the proposed metric is verified by assessing the test images in the LIVE database, and is compared with those of many well-know IQA metrics. Experimental results indicate that the proposed metric is an effective IQA method that can accurately predict the image quality of color images in terms of the correlation between objective scores and subjective evaluation.

  18. A comparison of different functions for predicted protein model quality assessment.

    PubMed

    Li, Juan; Fang, Huisheng

    2016-07-01

    In protein structure prediction, a considerable number of models are usually produced by either the Template-Based Method (TBM) or the ab initio prediction. The purpose of this study is to find the critical parameter in assessing the quality of the predicted models. A non-redundant template library was developed and 138 target sequences were modeled. The target sequences were all distant from the proteins in the template library and were aligned with template library proteins on the basis of the transformation matrix. The quality of each model was first assessed with QMEAN and its six parameters, which are C_β interaction energy (C_beta), all-atom pairwise energy (PE), solvation energy (SE), torsion angle energy (TAE), secondary structure agreement (SSA), and solvent accessibility agreement (SAE). Finally, the alignment score (score) was also used to assess the quality of model. Hence, a total of eight parameters (i.e., QMEAN, C_beta, PE, SE, TAE, SSA, SAE, score) were independently used to assess the quality of each model. The results indicate that SSA is the best parameter to estimate the quality of the model.

  19. A novel method of assessing quality of postgraduate psychiatry training: experiences from a large training programme

    PubMed Central

    2013-01-01

    Background Most assessments of the quality of postgraduate training are based on anonymised questionnaires of trainees. We report a comprehensive assessment of the quality of training at a large postgraduate psychiatry training institute using non-anonymised face-to-face interviews with trainees and their trainers. Methods Two consultant psychiatrists interviewed 99 trainees and 109 trainers. Scoring of interview responses was determined by using a pre-defined criteria. Additional comments were recorded as free text. Interviews covered 13 domains, including: Clinical, teaching, research and management opportunities, clinical environment, clinical supervision, adequacy of job description, absence of bullying and job satisfaction. Multiple interview domain scores were combined, generating a ‘Combined’ score for each post. Results The interview response rate was 97% for trainers 88% for trainees. There was a significant correlation between trainee and trainer scores for the same interview domains (Pearson’s r = 0.968, p< 0.001). Overall scores were significantly higher for specialist psychiatry posts as compared to general adult psychiatry posts (Two tailed t-test, p < 0.001, 95% CI: -0.398 to −0.132), and significantly higher for liaison psychiatry as compared to other specialist psychiatry posts (t-test: p = 0.038, 95% CI: -0.3901, -0.0118). Job satisfaction scores of year 1 to year 3 core trainees showed a significant increase with increasing seniority (Linear regression coefficient = 0.273, 95% CI: 0.033 to 0.513, ANOVA p= 0.026). Conclusions This in-depth examination of the quality of training on a large psychiatry training programme successfully elicited strengths and weakness of our programme. Such an interview scheme could be easily implemented in smaller schemes and may well provide important information to allow for targeted improvement of training. Additionally, trends in quality of training and job satisfaction amongst various psychiatric

  20. Water Quality Assessment and Management

    EPA Pesticide Factsheets

    Overview of Clean Water Act (CWA) restoration framework including; water quality standards, monitoring/assessment, reporting water quality status, TMDL development, TMDL implementation (point & nonpoint source control)

  1. Assessment of air quality in Haora River basin using fuzzy multiple-attribute decision making techniques.

    PubMed

    Singh, Ajit Pratap; Chakrabarti, Sumanta; Kumar, Sumit; Singh, Anjaney

    2017-08-01

    This paper deals with assessment of air quality in Haora River basin using two techniques. Initially, air quality indices were evaluated using a modified EPA method. The indices were also evaluated using a fuzzy comprehensive assessment (FCA) method. The results obtained from the fuzzy comprehensive assessment method were compared to that obtained from the modified EPA method. To illustrate the applicability of the methodology proposed herein, a case study has been presented. Air samples have been collected at 10 sampling sites located along Haora River. Six important air pollutants, namely, carbon monoxide, sulfur dioxide, nitrogen dioxide, suspended particulate matter (SPM), PM 10 , and lead, were monitored continuously, and air quality maps were generated on the GIS platform. Comparison of the methodologies has clearly highlighted superiority and robustness of the fuzzy comprehensive assessment method in determining air quality indices under study. It has effectively addressed the inherent uncertainties involved in the evaluation, modeling, and interpretation of sampling data, which was beyond the scope of the traditional weighted approaches employed otherwise. The FCA method is robust and prepares a credible platform of air quality evaluation and identification, in face of the uncertainties that remain eclipsed in the traditional approaches like the modified EPA method. The insights gained through the present study are believed to be of pivotal significance in guiding the development and implementation of effective environmental remedial action plans in the study area.

  2. Neural image analysis in the process of quality assessment: domestic pig oocytes

    NASA Astrophysics Data System (ADS)

    Boniecki, P.; Przybył, J.; Kuzimska, T.; Mueller, W.; Raba, B.; Lewicki, A.; Przybył, K.; Zaborowicz, M.; Koszela, K.

    2014-04-01

    The questions related to quality classification of animal oocytes are explored by numerous scientific and research centres. This research is important, particularly in the context of improving the breeding value of farm animals. The methods leading to the stimulation of normal development of a larger number of fertilised animal oocytes in extracorporeal conditions are of special importance. Growing interest in the techniques of supported reproduction resulted in searching for new, increasingly effective methods for quality assessment of mammalian gametes and embryos. Progress in the production of in vitro animal embryos in fact depends on proper classification of obtained oocytes. The aim of this paper was the development of an original method for quality assessment of oocytes, performed on the basis of their graphical presentation in the form of microscopic digital images. The classification process was implemented on the basis of the information coded in the form of microphotographic pictures of the oocytes of domestic pig, using the modern methods of neural image analysis.

  3. Quality of life among dermatology patients: a systematic review of investigations using qualitative methods.

    PubMed

    Singh, Sanminder; Ehsani-Chimeh, Nazanin; Kornmehl, Heather; Armstrong, April W

    2017-07-13

    Quality of life may be assessed using quantitative or qualitative methods. Quantitative methods are commonly used in research settings; however, they may fail to capture the full range of patient experiences and impact on quality of life. Qualitative methods may be used to address this limitation. In this systematic review, we aim to synthesize data from articles utilizing qualitative methods to assess quality of life in dermatology patients. We performed a systematic review search using the MEDLINE, EMBASE, and SCOPUS databases. The search was conducted using the following search criteria: ("Dermatology" [MeSH]) AND ("Quality of Life" [MeSH]), AND ("Qualitative Research" [MeSH]), searching literature spanning from January 1, 1946- October 5, 2016. The systematic review of 15 articles included 533 dermatology patients. Patients expressed frustration over the unpredictability of disease symptoms and having to compensate for the subsequent limitations by altering their daily routines. Patients also reported profound helplessness due to chronic skin disease and social isolation in an effort to hide their disease. Patients noted the patient-provider relationship as a source of support and information exchange, with the goal to form easy to use treatment plans that met both physician and patient expectations. Qualitative assessment of patient quality of life can provide new insights into the patient experience and the impact of their skin disease. Qualitative methodology may capture meaningful information that may be overlooked by quantitative methods, and it should be included in quality of life research.

  4. The creation, management, and use of data quality information for life cycle assessment.

    PubMed

    Edelen, Ashley; Ingwersen, Wesley W

    2018-04-01

    Despite growing access to data, questions of "best fit" data and the appropriate use of results in supporting decision making still plague the life cycle assessment (LCA) community. This discussion paper addresses revisions to assessing data quality captured in a new US Environmental Protection Agency guidance document as well as additional recommendations on data quality creation, management, and use in LCA databases and studies. Existing data quality systems and approaches in LCA were reviewed and tested. The evaluations resulted in a revision to a commonly used pedigree matrix, for which flow and process level data quality indicators are described, more clarity for scoring criteria, and further guidance on interpretation are given. Increased training for practitioners on data quality application and its limits are recommended. A multi-faceted approach to data quality assessment utilizing the pedigree method alongside uncertainty analysis in result interpretation is recommended. A method of data quality score aggregation is proposed and recommendations for usage of data quality scores in existing data are made to enable improved use of data quality scores in LCA results interpretation. Roles for data generators, data repositories, and data users are described in LCA data quality management. Guidance is provided on using data with data quality scores from other systems alongside data with scores from the new system. The new pedigree matrix and recommended data quality aggregation procedure can now be implemented in openLCA software. Additional ways in which data quality assessment might be improved and expanded are described. Interoperability efforts in LCA data should focus on descriptors to enable user scoring of data quality rather than translation of existing scores. Developing and using data quality indicators for additional dimensions of LCA data, and automation of data quality scoring through metadata extraction and comparison to goal and scope are needed.

  5. Quality of health care and the need for assessment.

    PubMed

    Bosse, G; Ngoli, B; Leshabari, M T; Külker, R; Dämmrich, T; Abels, W; Breuer, J P; Kersten, R; Spies, C

    2011-09-01

    In many hospitals of developing countries quality of care is below the expected standard to maintain patient safety. In 2006, health care experts from Tanzania and Germany collaborated on a set of indicators to be used as a hospital performance assessment tool. The aim of this study was to introduce this tool and check its feasibility for use in a Tanzanian regional hospital. Within the hospital, independent observers assessed quantitatively structural quality and the performance of health care encounter using an itemized scale from 0 (0%) to 2 (100%) for each defined item. Outcome parameters were taken from the annual hospital report. In addition, semi-qualitative interviews with staff and patients were held to a) assess staff knowledge of the treatment guidelines published by the Tanzanian Ministry of Health and Social Welfare (MoHSW), b) assess attitudes and user motivation and c) authenticate the quantitative findings in a mixed-method triangulation approach. Structural quality in maternity was at 75% of the expected standard, while process quality ranged from 36% (Care of the newborn with APGAR score < 4) to 47% (normal delivery procedure). Staff knowledge ranged between 64% and 87% with low motivation and commitment given as contributing factors. Outcome (maternal mortality) was 481/100,000 live births with an infant mortality rate of 10%. The tool appeared to be feasible and effective in judging care quality. It provides a model for continuous quality improvement. Motivation of health care workers, a strong determinant of care process quality, might be improved by strengthening internal factors in health facilities. For conclusive validation, further studies using the tool must be conducted with larger numbers of institutions.

  6. Assessment of sound quality perception in cochlear implant users during music listening.

    PubMed

    Roy, Alexis T; Jiradejvong, Patpong; Carver, Courtney; Limb, Charles J

    2012-04-01

    Although cochlear implant (CI) users frequently report deterioration of sound quality when listening to music, few methods exist to quantify these subjective claims. 1) To design a novel research method for quantifying sound quality perception in CI users during music listening; 2) To validate this method by assessing one attribute of music perception, bass frequency perception, which is hypothesized to be relevant to overall musical sound quality perception. Limitations in bass frequency perception contribute to CI-mediated sound quality deteriorations. The proposed method will quantify this deterioration by measuring CI users' impaired ability to make sound quality discriminations among musical stimuli with variable amounts of bass frequency removal. A method commonly used in the audio industry (multiple stimulus with hidden reference and anchor [MUSHRA]) was adapted for CI users, referred to as CI-MUSHRA. CI users and normal hearing controls were presented with 7 sound quality versions of a musical segment: 5 high pass filter cutoff versions (200-, 400-, 600-, 800-, 1000-Hz) with decreasing amounts of bass information, an unaltered version ("hidden reference"), and a highly altered version (1,000-1,200 Hz band pass filter; "anchor"). Participants provided sound quality ratings between 0 (very poor) and 100 (excellent) for each version; ratings reflected differences in perceived sound quality among stimuli. CI users had greater difficulty making overall sound quality discriminations as a function of bass frequency loss than normal hearing controls, as demonstrated by a significantly weaker correlation between bass frequency content and sound quality ratings. In particular, CI users could not perceive sound quality difference among stimuli missing up to 400 Hz of bass frequency information. Bass frequency impairments contribute to sound quality deteriorations during music listening for CI users. CI-MUSHRA provided a systematic and quantitative assessment of this

  7. Image and Imaging an Emergency Department: Expense and Benefit of Different Quality Assessment Methods

    PubMed Central

    Pfortmueller, Carmen Andrea; Keller, Michael; Mueller, Urs; Zimmermann, Heinz; Exadaktylos, Aristomenis Konstantinos

    2013-01-01

    Introduction. In this era of high-tech medicine, it is becoming increasingly important to assess patient satisfaction. There are several methods to do so, but these differ greatly in terms of cost, time, and labour and external validity. The aim of this study is to describe and compare the structure and implementation of different methods to assess the satisfaction of patients in an emergency department. Methods. The structure and implementation of the different methods to assess patient satisfaction were evaluated on the basis of a 90-minute standardised interview. Results. We identified a total of six different methods in six different hospitals. The average number of patients assessed was 5012, with a range from 230 (M5) to 20 000 patients (M2). In four methods (M1, M3, M5, and M6), the questionnaire was composed by a specialised external institute. In two methods, the questionnaire was created by the hospital itself (M2, M4).The median response rate was 58.4% (range 9–97.8%). With a reminder, the response rate increased by 60% (M3). Conclusion. The ideal method to assess patient satisfaction in the emergency department setting is to use a patient-based, in-emergency department-based assessment of patient satisfaction, planned and guided by expert personnel. PMID:23984073

  8. Portfolio Assessment and Quality Teaching

    ERIC Educational Resources Information Center

    Kim, Youb; Yazdian, Lisa Sensale

    2014-01-01

    Our article focuses on using portfolio assessment to craft quality teaching. Extant research literature on portfolio assessment suggests that the primary purpose of assessment is to serve learning, and portfolio assessments facilitate the process of making linkages among assessment, curriculum, and student learning (Asp, 2000; Bergeron, Wermuth,…

  9. Validation of no-reference image quality index for the assessment of digital mammographic images

    NASA Astrophysics Data System (ADS)

    de Oliveira, Helder C. R.; Barufaldi, Bruno; Borges, Lucas R.; Gabarda, Salvador; Bakic, Predrag R.; Maidment, Andrew D. A.; Schiabel, Homero; Vieira, Marcelo A. C.

    2016-03-01

    To ensure optimal clinical performance of digital mammography, it is necessary to obtain images with high spatial resolution and low noise, keeping radiation exposure as low as possible. These requirements directly affect the interpretation of radiologists. The quality of a digital image should be assessed using objective measurements. In general, these methods measure the similarity between a degraded image and an ideal image without degradation (ground-truth), used as a reference. These methods are called Full-Reference Image Quality Assessment (FR-IQA). However, for digital mammography, an image without degradation is not available in clinical practice; thus, an objective method to assess the quality of mammograms must be performed without reference. The purpose of this study is to present a Normalized Anisotropic Quality Index (NAQI), based on the Rényi entropy in the pseudo-Wigner domain, to assess mammography images in terms of spatial resolution and noise without any reference. The method was validated using synthetic images acquired through an anthropomorphic breast software phantom, and the clinical exposures on anthropomorphic breast physical phantoms and patient's mammograms. The results reported by this noreference index follow the same behavior as other well-established full-reference metrics, e.g., the peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM). Reductions of 50% on the radiation dose in phantom images were translated as a decrease of 4dB on the PSNR, 25% on the SSIM and 33% on the NAQI, evidencing that the proposed metric is sensitive to the noise resulted from dose reduction. The clinical results showed that images reduced to 53% and 30% of the standard radiation dose reported reductions of 15% and 25% on the NAQI, respectively. Thus, this index may be used in clinical practice as an image quality indicator to improve the quality assurance programs in mammography; hence, the proposed method reduces the subjectivity

  10. No-reference quality assessment based on visual perception

    NASA Astrophysics Data System (ADS)

    Li, Junshan; Yang, Yawei; Hu, Shuangyan; Zhang, Jiao

    2014-11-01

    The visual quality assessment of images/videos is an ongoing hot research topic, which has become more and more important for numerous image and video processing applications with the rapid development of digital imaging and communication technologies. The goal of image quality assessment (IQA) algorithms is to automatically assess the quality of images/videos in agreement with human quality judgments. Up to now, two kinds of models have been used for IQA, namely full-reference (FR) and no-reference (NR) models. For FR models, IQA algorithms interpret image quality as fidelity or similarity with a perfect image in some perceptual space. However, the reference image is not available in many practical applications, and a NR IQA approach is desired. Considering natural vision as optimized by the millions of years of evolutionary pressure, many methods attempt to achieve consistency in quality prediction by modeling salient physiological and psychological features of the human visual system (HVS). To reach this goal, researchers try to simulate HVS with image sparsity coding and supervised machine learning, which are two main features of HVS. A typical HVS captures the scenes by sparsity coding, and uses experienced knowledge to apperceive objects. In this paper, we propose a novel IQA approach based on visual perception. Firstly, a standard model of HVS is studied and analyzed, and the sparse representation of image is accomplished with the model; and then, the mapping correlation between sparse codes and subjective quality scores is trained with the regression technique of least squaresupport vector machine (LS-SVM), which gains the regressor that can predict the image quality; the visual metric of image is predicted with the trained regressor at last. We validate the performance of proposed approach on Laboratory for Image and Video Engineering (LIVE) database, the specific contents of the type of distortions present in the database are: 227 images of JPEG2000, 233

  11. Multiscale visual quality assessment for cluster analysis with self-organizing maps

    NASA Astrophysics Data System (ADS)

    Bernard, Jürgen; von Landesberger, Tatiana; Bremm, Sebastian; Schreck, Tobias

    2011-01-01

    Cluster analysis is an important data mining technique for analyzing large amounts of data, reducing many objects to a limited number of clusters. Cluster visualization techniques aim at supporting the user in better understanding the characteristics and relationships among the found clusters. While promising approaches to visual cluster analysis already exist, these usually fall short of incorporating the quality of the obtained clustering results. However, due to the nature of the clustering process, quality plays an important aspect, as for most practical data sets, typically many different clusterings are possible. Being aware of clustering quality is important to judge the expressiveness of a given cluster visualization, or to adjust the clustering process with refined parameters, among others. In this work, we present an encompassing suite of visual tools for quality assessment of an important visual cluster algorithm, namely, the Self-Organizing Map (SOM) technique. We define, measure, and visualize the notion of SOM cluster quality along a hierarchy of cluster abstractions. The quality abstractions range from simple scalar-valued quality scores up to the structural comparison of a given SOM clustering with output of additional supportive clustering methods. The suite of methods allows the user to assess the SOM quality on the appropriate abstraction level, and arrive at improved clustering results. We implement our tools in an integrated system, apply it on experimental data sets, and show its applicability.

  12. Diagnostic accuracy of different caries risk assessment methods. A systematic review.

    PubMed

    Senneby, Anna; Mejàre, Ingegerd; Sahlin, Nils-Eric; Svensäter, Gunnel; Rohlin, Madeleine

    2015-12-01

    To evaluate the accuracy of different methods used to identify individuals with increased risk of developing dental coronal caries. Studies on following methods were included: previous caries experience, tests using microbiota, buffering capacity, salivary flow rate, oral hygiene, dietary habits and sociodemographic variables. QUADAS-2 was used to assess risk of bias. Sensitivity, specificity, predictive values, and likelihood ratios (LR) were calculated. Quality of evidence based on ≥3 studies of a method was rated according to GRADE. PubMed, Cochrane Library, Web of Science and reference lists of included publications were searched up to January 2015. From 5776 identified articles, 18 were included. Assessment of study quality identified methodological limitations concerning study design, test technology and reporting. No study presented low risk of bias in all domains. Three or more studies were found only for previous caries experience and salivary mutans streptococci and quality of evidence for these methods was low. Evidence regarding other methods was lacking. For previous caries experience, sensitivity ranged between 0.21 and 0.94 and specificity between 0.20 and 1. Tests using salivary mutans streptococci resulted in low sensitivity and high specificity. For children with primary teeth at baseline, pooled LR for a positive test was 3 for previous caries experience and 4 for salivary mutans streptococci, given a threshold ≥10(5) CFU/ml. Evidence on the validity of analysed methods used for caries risk assessment is limited. As methodological quality was low, there is a need to improve study design. Low validity for the analysed methods may lead to patients with increased risk not being identified, whereas some are falsely identified as being at risk. As caries risk assessment guides individualized decisions on interventions and intervals for patient recall, improved performance based on best evidence is greatly needed. Copyright © 2015 Elsevier Ltd

  13. Subjective Quality Assessment of Underwater Video for Scientific Applications

    PubMed Central

    Moreno-Roldán, José-Miguel; Luque-Nieto, Miguel-Ángel; Poncela, Javier; Díaz-del-Río, Víctor; Otero, Pablo

    2015-01-01

    Underwater video services could be a key application in the better scientific knowledge of the vast oceanic resources in our planet. However, limitations in the capacity of current available technology for underwater networks (UWSNs) raise the question of the feasibility of these services. When transmitting video, the main constraints are the limited bandwidth and the high propagation delays. At the same time the service performance depends on the needs of the target group. This paper considers the problems of estimations for the Mean Opinion Score (a standard quality measure) in UWSNs based on objective methods and addresses the topic of quality assessment in potential underwater video services from a subjective point of view. The experimental design and the results of a test planned according standardized psychometric methods are presented. The subjects used in the quality assessment test were ocean scientists. Video sequences were recorded in actual exploration expeditions and were processed to simulate conditions similar to those that might be found in UWSNs. Our experimental results show how videos are considered to be useful for scientific purposes even in very low bitrate conditions. PMID:26694400

  14. Applicability of ambient toxicity testing to national or regional water-quality assessment

    USGS Publications Warehouse

    Elder, J.F.

    1989-01-01

    Comprehensive assessment of the quality of natural waters requires a multifaceted approach. Based on experimentation designed to monitor responses of organisms to environmental stresses, toxicity testing may have diverse purposes in water quality assessments. These purposes may include identification that warrant further study because of poor water quality or unusual ecological features, verification of other types of monitoring, or assessment of contaminant effects on aquatic communities. A wide variety of toxicity test methods have been developed to fulfill the needs of diverse applications. The methods differ primarily in the full selections made relative to four characteristics: (1) test species, (2) endpoints (acute or chronic), (3) test enclosure type, and (4) test substance (toxicant) that functions as the environmental stress. Toxicity test approachs vary in their capacity to meet the needs of large-scale assessments of existing water quality. Ambient testing is more likely to meet these needs than are the procedures that call for exposure of the test organisms to known concentrations of a single toxicant. However, meaningful interpretation of ambient test results depend on the existence of accompanying chemical analysis of the ambient media. The ambient test substance may be water or sediments. Sediment tests have had limited application, but they are useful because of the fact that most toxicants tend to accumulate in sediments, and many test species either inhabit the sediments or are in frequent contact with them. Biochemical testing methods, which have been developing rapidly in recent years, are likely to be among the most useful procedures for large-scale water quality assessments. They are relatively rapid and simple, and more importantly, they focus on biochemical changes that are the initial responses of virtually all organisms to environmental stimuli. Most species are sensitive to relatively few toxicants and their sensitivities vary as

  15. How the modified method of orbit quality assessment works for Oort spike comets?

    NASA Astrophysics Data System (ADS)

    Królikowska, Małgorzata; Dybczyński, Piotr A.

    2018-06-01

    We present a brief overview of the effectiveness of the modified method of a quality of orbit estimation proposed by us a few years ago. Having now a complete sample of 100 Oort spike comets with large perihelion distances, we show that it was justified to introduce more restricted conditions separating the individual quality classes as well as introducing a new quality class containing orbits of the excellent quality, marked by us as 1a+. To enrich the perception, we provided a complete collection of visual time distributions of positional data sets used by us for an orbit determination (see the Appendix). We show that modern positional measurements of large-perihelion Oort spike comets should be carried out for at least 3 yr around perihelion (three-four oppositions) to be almost certain that the derived orbit will be of the highest quality (1a+ class). Our results strongly support an expectation that in near future it will be possible to study the shape of 1/aori-distribution of the Oort spike comets in great detail basing only on the highest quality orbits, having 1/aori-uncertainties well below 5 × 10-6 au-1.

  16. Performance Assessment Examples from the Quality Performance Assessment Network

    ERIC Educational Resources Information Center

    Kuriacose, Christina

    2017-01-01

    In this brief article, Christina Kuriacose provides four sample performance assessments. Spanning grade levels, these assessments are strong examples of teacher-developed performance assessments from schools within the Center for Collaborative Education's Quality Performance Assessment network. These performance tasks demonstrate the pedagogical…

  17. Efficient method for assessing channel instability near bridges

    USGS Publications Warehouse

    Robinson, Bret A.; Thompson, R.E.

    1993-01-01

    Efficient methods for data collection and processing are required to complete channel-instability assessments at 5,600 bridge sites in Indiana at an affordable cost and within a reasonable time frame while maintaining the quality of the assessments. To provide this needed efficiency and quality control, a data-collection form was developed that specifies the data to be collected and the order of data collection. This form represents a modification of previous forms that grouped variables according to type rather than by order of collection. Assessments completed during two field seasons showed that greater efficiency was achieved by using a fill-in-the-blank form that organizes the data to be recorded in a specified order: in the vehicle, from the roadway, in the upstream channel, under the bridge, and in the downstream channel.

  18. Method and apparatus for assessing weld quality

    DOEpatents

    Smartt, Herschel B.; Kenney, Kevin L.; Johnson, John A.; Carlson, Nancy M.; Clark, Denis E.; Taylor, Paul L.; Reutzel, Edward W.

    2001-01-01

    Apparatus for determining a quality of a weld produced by a welding device according to the present invention includes a sensor operatively associated with the welding device. The sensor is responsive to at least one welding process parameter during a welding process and produces a welding process parameter signal that relates to the at least one welding process parameter. A computer connected to the sensor is responsive to the welding process parameter signal produced by the sensor. A user interface operatively associated with the computer allows a user to select a desired welding process. The computer processes the welding process parameter signal produced by the sensor in accordance with one of a constant voltage algorithm, a short duration weld algorithm or a pulsed current analysis module depending on the desired welding process selected by the user. The computer produces output data indicative of the quality of the weld.

  19. Methods for examining data quality in healthcare integrated data repositories.

    PubMed

    Huser, Vojtech; Kahn, Michael G; Brown, Jeffrey S; Gouripeddi, Ramkiran

    2018-01-01

    This paper summarizes content of the workshop focused on data quality. The first speaker (VH) described data quality infrastructure and data quality evaluation methods currently in place within the Observational Data Science and Informatics (OHDSI) consortium. The speaker described in detail a data quality tool called Achilles Heel and latest development for extending this tool. Interim results of an ongoing Data Quality study within the OHDSI consortium were also presented. The second speaker (MK) described lessons learned and new data quality checks developed by the PEDsNet pediatric research network. The last two speakers (JB, RG) described tools developed by the Sentinel Initiative and University of Utah's service oriented framework. The workshop discussed at the end and throughout how data quality assessment can be advanced by combining best features of each network.

  20. Colonoscopy video quality assessment using hidden Markov random fields

    NASA Astrophysics Data System (ADS)

    Park, Sun Young; Sargent, Dusty; Spofford, Inbar; Vosburgh, Kirby

    2011-03-01

    With colonoscopy becoming a common procedure for individuals aged 50 or more who are at risk of developing colorectal cancer (CRC), colon video data is being accumulated at an ever increasing rate. However, the clinically valuable information contained in these videos is not being maximally exploited to improve patient care and accelerate the development of new screening methods. One of the well-known difficulties in colonoscopy video analysis is the abundance of frames with no diagnostic information. Approximately 40% - 50% of the frames in a colonoscopy video are contaminated by noise, acquisition errors, glare, blur, and uneven illumination. Therefore, filtering out low quality frames containing no diagnostic information can significantly improve the efficiency of colonoscopy video analysis. To address this challenge, we present a quality assessment algorithm to detect and remove low quality, uninformative frames. The goal of our algorithm is to discard low quality frames while retaining all diagnostically relevant information. Our algorithm is based on a hidden Markov model (HMM) in combination with two measures of data quality to filter out uninformative frames. Furthermore, we present a two-level framework based on an embedded hidden Markov model (EHHM) to incorporate the proposed quality assessment algorithm into a complete, automated diagnostic image analysis system for colonoscopy video.

  1. Methodological quality of meta-analyses on treatments for chronic obstructive pulmonary disease: a cross-sectional study using the AMSTAR (Assessing the Methodological Quality of Systematic Reviews) tool

    PubMed Central

    Ho, Robin ST; Wu, Xinyin; Yuan, Jinqiu; Liu, Siya; Lai, Xin; Wong, Samuel YS; Chung, Vincent CH

    2015-01-01

    Background: Meta-analysis (MA) of randomised trials is considered to be one of the best approaches for summarising high-quality evidence on the efficacy and safety of treatments. However, methodological flaws in MAs can reduce the validity of conclusions, subsequently impairing the quality of decision making. Aims: To assess the methodological quality of MAs on COPD treatments. Methods: A cross-sectional study on MAs of COPD trials. MAs published during 2000–2013 were sampled from the Cochrane Database of Systematic Reviews and Database of Abstracts of Reviews of Effect. Methodological quality was assessed using the validated AMSTAR (Assessing the Methodological Quality of Systematic Reviews) tool. Results: Seventy-nine MAs were sampled. Only 18% considered the scientific quality of primary studies when formulating conclusions and 49% used appropriate meta-analytic methods to combine findings. The problems were particularly acute among MAs on pharmacological treatments. In 48% of MAs the authors did not report conflict of interest. Fifty-eight percent reported harmful effects of treatment. Publication bias was not assessed in 65% of MAs, and only 10% had searched non-English databases. Conclusions: The methodological quality of the included MAs was disappointing. Consideration of scientific quality when formulating conclusions should be made explicit. Future MAs should improve on reporting conflict of interest and harm, assessment of publication bias, prevention of language bias and use of appropriate meta-analytic methods. PMID:25569783

  2. Guidance on Data Quality Assessment for Life Cycle Inventory ...

    EPA Pesticide Factsheets

    Data quality within Life Cycle Assessment (LCA) is a significant issue for the future support and development of LCA as a decision support tool and its wider adoption within industry. In response to current data quality standards such as the ISO 14000 series, various entities within the LCA community have developed different methodologies to address and communicate the data quality of Life Cycle Inventory (LCI) data. Despite advances in this field, the LCA community is still plagued by the lack of reproducible data quality results and documentation. To address these issues, US EPA has created this guidance in order to further support reproducible life cycle inventory data quality results and to inform users of the proper application of the US EPA supported data quality system. The work for this report was begun in December 2014 and completed as of April 2016.The updated data quality system includes a novel approach to the pedigree matrix by addressing data quality at the flow and the process level. Flow level indicators address source reliability, temporal correlation, geographic correlation, technological correlation and data sampling methods. The process level indicators address the level of review the unit process has undergone and its completeness. This guidance is designed to be updatable as part of the LCA Research Center’s continuing commitment to data quality advancements. Life cycle assessment is increasingly being used as a tool to identify areas of

  3. Quality assessment of SPR sensor chips; case study on L1 chips.

    PubMed

    Olaru, Andreea; Gheorghiu, Mihaela; David, Sorin; Polonschii, Cristina; Gheorghiu, Eugen

    2013-07-15

    Surface quality of the Surface Plasmon Resonance (SPR) chips is a major limiting issue in most SPR analyses, even more for supported lipid membranes experiments, where both the organization of the lipid matrix and the subsequent incorporation of the target molecule depend on the surface quality. A novel quantitative method to characterize the quality of SPR sensors chips is described for L1 chips subject to formation of lipid films, injection of membrane disrupting compounds, followed by appropriate regeneration procedures. The method consists in analysis of the SPR reflectivity curves for several standard solutions (e.g. PBS, HEPES or deionized water). This analysis reveals the decline of sensor surface as a function of the number of experimental cycles (consisting in biosensing assay and regeneration step) and enables active control of surface regeneration for enhanced reproducibility. We demonstrate that quantitative evaluation of the changes in reflectivity curves (shape of the SPR dip) and of the slope of the calibration curve provides a rapid and effective procedure for surface quality assessment. Whereas the method was tested on L1 SPR sensors chips, we stress on its amenability to assess the quality of other types of SPR chips, as well. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Validation of personal digital photography to assess dietary quality among people with intellectual disabilities.

    PubMed

    Elinder, L S; Brunosson, A; Bergström, H; Hagströmer, M; Patterson, E

    2012-02-01

    Dietary assessment is a challenge in general, and specifically in individuals with intellectual disabilities (ID). This study aimed to evaluate personal digital photography as a method of assessing different aspects of dietary quality in this target group. Eighteen adults with ID were recruited from community residences and activity centres in Stockholm County. Participants were instructed to photograph all foods and beverages consumed during 1 day, while observed. Photographs were coded by two raters. Observations and photographs of meal frequency, intake occasions of four specific food and beverage items, meal quality and dietary diversity were compared. Evaluation of inter-rater reliability and validity of the method was performed by intra-class correlation analysis. With reminders from staff, 85% of all observed eating or drinking occasions were photographed. The inter-rater reliability was excellent for all assessed variables (ICC ≥ 0.88), except for meal quality where ICC was 0.66. The correlations between items assessed in photos and observations were strong to almost perfect with ICC values ranging from 0.71 to 0.92 and all were statistically significant. Personal digital photography appears to be a feasible, reliable and valid method for assessing dietary quality in people with mild to moderate ID, who have daily staff support. © 2011 The Authors. Journal of Intellectual Disability Research © 2011 Blackwell Publishing Ltd.

  5. Identifying approaches for assessing methodological and reporting quality of systematic reviews: a descriptive study.

    PubMed

    Pussegoda, Kusala; Turner, Lucy; Garritty, Chantelle; Mayhew, Alain; Skidmore, Becky; Stevens, Adrienne; Boutron, Isabelle; Sarkis-Onofre, Rafael; Bjerre, Lise M; Hróbjartsson, Asbjørn; Altman, Douglas G; Moher, David

    2017-06-19

    The methodological quality and completeness of reporting of the systematic reviews (SRs) is fundamental to optimal implementation of evidence-based health care and the reduction of research waste. Methods exist to appraise SRs yet little is known about how they are used in SRs or where there are potential gaps in research best-practice guidance materials. The aims of this study are to identify reports assessing the methodological quality (MQ) and/or reporting quality (RQ) of a cohort of SRs and to assess their number, general characteristics, and approaches to 'quality' assessment over time. The Cochrane Library, MEDLINE®, and EMBASE® were searched from January 1990 to October 16, 2014, for reports assessing MQ and/or RQ of SRs. Title, abstract, and full-text screening of all reports were conducted independently by two reviewers. Reports assessing the MQ and/or RQ of a cohort of ten or more SRs of interventions were included. All results are reported as frequencies and percentages of reports. Of 20,765 unique records retrieved, 1189 of them were reviewed for full-text review, of which 76 reports were included. Eight previously published approaches to assessing MQ or reporting guidelines used as proxy to assess RQ were used in 80% (61/76) of identified reports. These included two reporting guidelines (PRISMA and QUOROM) and five quality assessment tools (AMSTAR, R-AMSTAR, OQAQ, Mulrow, Sacks) and GRADE criteria. The remaining 24% (18/76) of reports developed their own criteria. PRISMA, OQAQ, and AMSTAR were the most commonly used published tools to assess MQ or RQ. In conjunction with other approaches, published tools were used in 29% (22/76) of reports, with 36% (8/22) assessing adherence to both PRISMA and AMSTAR criteria and 26% (6/22) using QUOROM and OQAQ. The methods used to assess quality of SRs are diverse, and none has become universally accepted. The most commonly used quality assessment tools are AMSTAR, OQAQ, and PRISMA. As new tools and guidelines are

  6. Field Application of the Micro Biological Survey Method for a Simple and Effective Assessment of the Microbiological Quality of Water Sources in Developing Countries

    PubMed Central

    Arienzo, Alyexandra; Sobze, Martin Sanou; Wadoum, Raoul Emeric Guetiya; Losito, Francesca; Colizzi, Vittorio; Antonini, Giovanni

    2015-01-01

    According to the World Health Organization (WHO) guidelines, “safe drinking-water must not represent any significant risk to health over a lifetime of consumption, including different sensitivities that may occur between life stages”. Traditional methods of water analysis are usually complex, time consuming and require an appropriately equipped laboratory, specialized personnel and expensive instrumentation. The aim of this work was to apply an alternative method, the Micro Biological Survey (MBS), to analyse for contaminants in drinking water. Preliminary experiments were carried out to demonstrate the linearity and accuracy of the MBS method and to verify the possibility of using the evaluation of total coliforms in 1 mL of water as a sufficient parameter to roughly though accurately determine water microbiological quality. The MBS method was then tested “on field” to assess the microbiological quality of water sources in the city of Douala (Cameroon, Central Africa). Analyses were performed on both dug and drilled wells in different periods of the year. Results confirm that the MBS method appears to be a valid and accurate method to evaluate the microbiological quality of many water sources and it can be of valuable aid in developing countries. PMID:26308038

  7. Field Application of the Micro Biological Survey Method for a Simple and Effective Assessment of the Microbiological Quality of Water Sources in Developing Countries.

    PubMed

    Arienzo, Alyexandra; Sobze, Martin Sanou; Wadoum, Raoul Emeric Guetiya; Losito, Francesca; Colizzi, Vittorio; Antonini, Giovanni

    2015-08-25

    According to the World Health Organization (WHO) guidelines, "safe drinking-water must not represent any significant risk to health over a lifetime of consumption, including different sensitivities that may occur between life stages". Traditional methods of water analysis are usually complex, time consuming and require an appropriately equipped laboratory, specialized personnel and expensive instrumentation. The aim of this work was to apply an alternative method, the Micro Biological Survey (MBS), to analyse for contaminants in drinking water. Preliminary experiments were carried out to demonstrate the linearity and accuracy of the MBS method and to verify the possibility of using the evaluation of total coliforms in 1 mL of water as a sufficient parameter to roughly though accurately determine water microbiological quality. The MBS method was then tested "on field" to assess the microbiological quality of water sources in the city of Douala (Cameroon, Central Africa). Analyses were performed on both dug and drilled wells in different periods of the year. Results confirm that the MBS method appears to be a valid and accurate method to evaluate the microbiological quality of many water sources and it can be of valuable aid in developing countries.

  8. [Environmental quality assessment of regional agro-ecosystem in Loess Plateau].

    PubMed

    Wang, Limei; Meng, Fanping; Zheng, Jiyong; Wang, Zhonglin

    2004-03-01

    Based on the detection and analysis of the contamination status of agro-ecosystem with apple-crops intercropping as the dominant cropping model in Loess Plateau, the individual factor and comprehensive environmental quality were assessed by multilevel fuzzy synthetic evaluation model, analytical hierarchy process(AHP), and improved standard weight deciding method. The results showed that the quality of soil, water and agricultural products was grade I, the social economical environmental quality was grade II, the ecological environmental quality was grade III, and the comprehensive environmental quality was grade I. The regional agro-ecosystem dominated by apple-crops intercropping was not the best model for the ecological benefits, but had the better social economical benefits.

  9. An objective method for a video quality evaluation in a 3DTV service

    NASA Astrophysics Data System (ADS)

    Wilczewski, Grzegorz

    2015-09-01

    The following article describes proposed objective method for a 3DTV video quality evaluation, a Compressed Average Image Intensity (CAII) method. Identification of the 3DTV service's content chain nodes enables to design a versatile, objective video quality metric. It is based on an advanced approach to the stereoscopic videostream analysis. Insights towards designed metric mechanisms, as well as the evaluation of performance of the designed video quality metric, in the face of the simulated environmental conditions are herein discussed. As a result, created CAII metric might be effectively used in a variety of service quality assessment applications.

  10. Data Quality Assessment Methods for the Eastern Range 915 MHz Wind Profiler Network

    NASA Technical Reports Server (NTRS)

    Lambert, Winifred C.; Taylor, Gregory E.

    1998-01-01

    The Eastern Range installed a network of five 915 MHz Doppler Radar Wind Profilers with Radio Acoustic Sounding Systems in the Cape Canaveral Air Station/Kennedy Space Center area to provide three-dimensional wind speed and direction and virtual temperature estimates in the boundary layer. The Applied Meteorology Unit, staffed by ENSCO, Inc., was tasked by the 45th Weather Squadron, the Spaceflight Meteorology Group, and the National Weather Service in Melbourne, Florida to investigate methods which will help forecasters assess profiler network data quality when developing forecasts and warnings for critical ground, launch and landing operations. Four routines were evaluated in this study: a consensus time period check a precipitation contamination check, a median filter, and the Weber-Wuertz (WW) algorithm. No routine was able to effectively flag suspect data when used by itself. Therefore, the routines were used in different combinations. An evaluation of all possible combinations revealed two that provided the best results. The precipitation contamination and consensus time routines were used in both combinations. The median filter or WW was used as the final routine in the combinations to flag all other suspect data points.

  11. Full-reference quality assessment of stereoscopic images by learning binocular receptive field properties.

    PubMed

    Shao, Feng; Li, Kemeng; Lin, Weisi; Jiang, Gangyi; Yu, Mei; Dai, Qionghai

    2015-10-01

    Quality assessment of 3D images encounters more challenges than its 2D counterparts. Directly applying 2D image quality metrics is not the solution. In this paper, we propose a new full-reference quality assessment for stereoscopic images by learning binocular receptive field properties to be more in line with human visual perception. To be more specific, in the training phase, we learn a multiscale dictionary from the training database, so that the latent structure of images can be represented as a set of basis vectors. In the quality estimation phase, we compute sparse feature similarity index based on the estimated sparse coefficient vectors by considering their phase difference and amplitude difference, and compute global luminance similarity index by considering luminance changes. The final quality score is obtained by incorporating binocular combination based on sparse energy and sparse complexity. Experimental results on five public 3D image quality assessment databases demonstrate that in comparison with the most related existing methods, the devised algorithm achieves high consistency with subjective assessment.

  12. Operational CryoSat Product Quality Assessment

    NASA Astrophysics Data System (ADS)

    Mannan, Rubinder; Webb, Erica; Hall, Amanda; Bouzinac, Catherine

    2013-12-01

    The performance and quality of the CryoSat data products are routinely assessed by the Instrument Data quality Evaluation and Analysis Service (IDEAS). This information is then conveyed to the scientific and user community in order to allow them to utilise CryoSat data with confidence. This paper presents details of the Quality Control (QC) activities performed for CryoSat products under the IDEAS contract. Details of the different QC procedures and tools deployed by IDEAS to assess the quality of operational data are presented. The latest updates to the Instrument Processing Facility (IPF) for the Fast Delivery Marine (FDM) products and the future update to Baseline-C are discussed.

  13. The Quality of Methods Reporting in Parasitology Experiments

    PubMed Central

    Flórez-Vargas, Oscar; Bramhall, Michael; Noyes, Harry; Cruickshank, Sheena; Stevens, Robert; Brass, Andy

    2014-01-01

    There is a growing concern both inside and outside the scientific community over the lack of reproducibility of experiments. The depth and detail of reported methods are critical to the reproducibility of findings, but also for making it possible to compare and integrate data from different studies. In this study, we evaluated in detail the methods reporting in a comprehensive set of trypanosomiasis experiments that should enable valid reproduction, integration and comparison of research findings. We evaluated a subset of other parasitic (Leishmania, Toxoplasma, Plasmodium, Trichuris and Schistosoma) and non-parasitic (Mycobacterium) experimental infections in order to compare the quality of method reporting more generally. A systematic review using PubMed (2000–2012) of all publications describing gene expression in cells and animals infected with Trypanosoma spp was undertaken based on PRISMA guidelines; 23 papers were identified and included. We defined a checklist of essential parameters that should be reported and have scored the number of those parameters that are reported for each publication. Bibliometric parameters (impact factor, citations and h-index) were used to look for association between Journal and Author status and the quality of method reporting. Trichuriasis experiments achieved the highest scores and included the only paper to score 100% in all criteria. The mean of scores achieved by Trypanosoma articles through the checklist was 65.5% (range 32–90%). Bibliometric parameters were not correlated with the quality of method reporting (Spearman's rank correlation coefficient <−0.5; p>0.05). Our results indicate that the quality of methods reporting in experimental parasitology is a cause for concern and it has not improved over time, despite there being evidence that most of the assessed parameters do influence the results. We propose that our set of parameters be used as guidelines to improve the quality of the reporting of experimental

  14. The quality of methods reporting in parasitology experiments.

    PubMed

    Flórez-Vargas, Oscar; Bramhall, Michael; Noyes, Harry; Cruickshank, Sheena; Stevens, Robert; Brass, Andy

    2014-01-01

    There is a growing concern both inside and outside the scientific community over the lack of reproducibility of experiments. The depth and detail of reported methods are critical to the reproducibility of findings, but also for making it possible to compare and integrate data from different studies. In this study, we evaluated in detail the methods reporting in a comprehensive set of trypanosomiasis experiments that should enable valid reproduction, integration and comparison of research findings. We evaluated a subset of other parasitic (Leishmania, Toxoplasma, Plasmodium, Trichuris and Schistosoma) and non-parasitic (Mycobacterium) experimental infections in order to compare the quality of method reporting more generally. A systematic review using PubMed (2000-2012) of all publications describing gene expression in cells and animals infected with Trypanosoma spp was undertaken based on PRISMA guidelines; 23 papers were identified and included. We defined a checklist of essential parameters that should be reported and have scored the number of those parameters that are reported for each publication. Bibliometric parameters (impact factor, citations and h-index) were used to look for association between Journal and Author status and the quality of method reporting. Trichuriasis experiments achieved the highest scores and included the only paper to score 100% in all criteria. The mean of scores achieved by Trypanosoma articles through the checklist was 65.5% (range 32-90%). Bibliometric parameters were not correlated with the quality of method reporting (Spearman's rank correlation coefficient <-0.5; p>0.05). Our results indicate that the quality of methods reporting in experimental parasitology is a cause for concern and it has not improved over time, despite there being evidence that most of the assessed parameters do influence the results. We propose that our set of parameters be used as guidelines to improve the quality of the reporting of experimental infection

  15. Physician performance assessment using a composite quality index.

    PubMed

    Liu, Kaibo; Jain, Shabnam; Shi, Jianjun

    2013-07-10

    Assessing physician performance is important for the purposes of measuring and improving quality of service and reducing healthcare delivery costs. In recent years, physician performance scorecards have been used to provide feedback on individual measures; however, one key challenge is how to develop a composite quality index that combines multiple measures for overall physician performance evaluation. A controversy arises over establishing appropriate weights to combine indicators in multiple dimensions, and cannot be easily resolved. In this study, we proposed a generic unsupervised learning approach to develop a single composite index for physician performance assessment by using non-negative principal component analysis. We developed a new algorithm named iterative quadratic programming to solve the numerical issue in the non-negative principal component analysis approach. We conducted real case studies to demonstrate the performance of the proposed method. We provided interpretations from both statistical and clinical perspectives to evaluate the developed composite ranking score in practice. In addition, we implemented the root cause assessment techniques to explain physician performance for improvement purposes. Copyright © 2012 John Wiley & Sons, Ltd.

  16. Towards Quality Assessment in an EFL Programme

    ERIC Educational Resources Information Center

    Ali, Holi Ibrahim Holi; Al Ajmi, Ahmed Ali Saleh

    2013-01-01

    Assessment is central in education and the teaching-learning process. This study attempts to explore the perspectives and views about quality assessment among teachers of English as a Foreign Language (EFL), and to find ways of promoting quality assessment. Quantitative methodology was used to collect data. To answer the study questions, a…

  17. Objective quality assessment of tone-mapped images.

    PubMed

    Yeganeh, Hojatollah; Wang, Zhou

    2013-02-01

    Tone-mapping operators (TMOs) that convert high dynamic range (HDR) to low dynamic range (LDR) images provide practically useful tools for the visualization of HDR images on standard LDR displays. Different TMOs create different tone-mapped images, and a natural question is which one has the best quality. Without an appropriate quality measure, different TMOs cannot be compared, and further improvement is directionless. Subjective rating may be a reliable evaluation method, but it is expensive and time consuming, and more importantly, is difficult to be embedded into optimization frameworks. Here we propose an objective quality assessment algorithm for tone-mapped images by combining: 1) a multiscale signal fidelity measure on the basis of a modified structural similarity index and 2) a naturalness measure on the basis of intensity statistics of natural images. Validations using independent subject-rated image databases show good correlations between subjective ranking score and the proposed tone-mapped image quality index (TMQI). Furthermore, we demonstrate the extended applications of TMQI using two examples-parameter tuning for TMOs and adaptive fusion of multiple tone-mapped images.

  18. Groundwater quality assessment of the quaternary unconsolidated sedimentary basin near the Pi river using fuzzy evaluation technique

    NASA Astrophysics Data System (ADS)

    Mohamed, Adam Khalifa; Liu, Dan; Mohamed, Mohamed A. A.; Song, Kai

    2018-05-01

    The present study was carried out to assess the groundwater quality for drinking purposes in the Quaternary Unconsolidated Sedimentary Basin of the North Chengdu Plain, China. Six groups of water samples (S1, S2, S3, S4, S5, and S6) are selected in the study area. These samples were analyzed for 19 different physicochemical water quality parameters to assess groundwater quality. The physicochemical parameters of groundwater were compared with China's Quality Standards for Groundwater (GB/T14848-93). Interpretation of physicochemical data revealed that groundwater in the basin was slightly alkaline. Total hardness and total dissolved solid values show that the investigated water is classified as very hard and fresh water, respectively. The sustainability of groundwater for drinking purposes was assessed based on the fuzzy mathematics evaluation (FME) method. The results of the assessment were classified into five groups based on their relative suitability for portable use (grade I = most suitable to grade V = least suitable), according to (GB/T 14848-93). The assessment results reveal that the quality of groundwater in most of the wells was class I, II and III and suitable for drinking purposes, but well (S2) has been found to be in class V, which is classified as very poor and cannot be used for drinking. Also, the FME method was compared with the comprehensive evaluation method. The FME method was found to be more comprehensive and reasonable to assess groundwater quality. This study can provide an important frame of reference for decision making on improving groundwater quality in the study area and nearby surrounding.

  19. Life quality assessment among patients with atopic eczema.

    PubMed

    Holm, E A; Wulf, H C; Stegmann, H; Jemec, G B E

    2006-04-01

    Quantification of quality of life (QoL) related to disease severity is important in patients with atopic eczema (AE), because the assessment provides additional information to the traditional objective clinical scoring systems. To measure health-related QoL (HRQoL) in patients with AE; to analyse discriminant, divergent and convergent validity by examining the association between various QoL methods; and to examine the association between disease severity assessed by an objective Severity Scoring of Atopic Dermatitis (SCORAD) and QoL. HRQoL was assessed at two visits at a 6-monthly interval in 101 patients with AE and 30 controls with one dermatology-specific questionnaire [Dermatology Life Quality Index (DLQI) or Children's DLQI (CDLQI)], one generic instrument (SF-36) and three visual analogue scales (VASs) of severity and pruritus. Objective SCORAD was used to measure disease severity. Patients with AE had significantly lower QoL than healthy controls and the general population. DLQI /CDLQI, pruritus, and patient and investigator overall assessment of eczema severity were significantly (P < 0.0001) and positively correlated with SCORAD, while the generic questionnaire showed only poor correlation. A gender difference was found for the mental component score of SF-36 (P = 0.019). AE has an impact on HRQoL. Patients' mental health, social functioning and role emotional functioning seem to be more affected than physical functioning. A simple VAS score of patients' assessment of disease severity showed the highest and most significant correlations with most of the HRQoL methods used. There is evidence to support the ability of patients with AE to make an accurate determination of their disease severity and QoL.

  20. Blind CT image quality assessment via deep learning strategy: initial study

    NASA Astrophysics Data System (ADS)

    Li, Sui; He, Ji; Wang, Yongbo; Liao, Yuting; Zeng, Dong; Bian, Zhaoying; Ma, Jianhua

    2018-03-01

    Computed Tomography (CT) is one of the most important medical imaging modality. CT images can be used to assist in the detection and diagnosis of lesions and to facilitate follow-up treatment. However, CT images are vulnerable to noise. Actually, there are two major source intrinsically causing the CT data noise, i.e., the X-ray photo statistics and the electronic noise background. Therefore, it is necessary to doing image quality assessment (IQA) in CT imaging before diagnosis and treatment. Most of existing CT images IQA methods are based on human observer study. However, these methods are impractical in clinical for their complex and time-consuming. In this paper, we presented a blind CT image quality assessment via deep learning strategy. A database of 1500 CT images is constructed, containing 300 high-quality images and 1200 corresponding noisy images. Specifically, the high-quality images were used to simulate the corresponding noisy images at four different doses. Then, the images are scored by the experienced radiologists by the following attributes: image noise, artifacts, edge and structure, overall image quality, and tumor size and boundary estimation with five-point scale. We trained a network for learning the non-liner map from CT images to subjective evaluation scores. Then, we load the pre-trained model to yield predicted score from the test image. To demonstrate the performance of the deep learning network in IQA, correlation coefficients: Pearson Linear Correlation Coefficient (PLCC) and Spearman Rank Order Correlation Coefficient (SROCC) are utilized. And the experimental result demonstrate that the presented deep learning based IQA strategy can be used in the CT image quality assessment.

  1. Perceptual video quality assessment in H.264 video coding standard using objective modeling.

    PubMed

    Karthikeyan, Ramasamy; Sainarayanan, Gopalakrishnan; Deepa, Subramaniam Nachimuthu

    2014-01-01

    Since usage of digital video is wide spread nowadays, quality considerations have become essential, and industry demand for video quality measurement is rising. This proposal provides a method of perceptual quality assessment in H.264 standard encoder using objective modeling. For this purpose, quality impairments are calculated and a model is developed to compute the perceptual video quality metric based on no reference method. Because of the shuttle difference between the original video and the encoded video the quality of the encoded picture gets degraded, this quality difference is introduced by the encoding process like Intra and Inter prediction. The proposed model takes into account of the artifacts introduced by these spatial and temporal activities in the hybrid block based coding methods and an objective modeling of these artifacts into subjective quality estimation is proposed. The proposed model calculates the objective quality metric using subjective impairments; blockiness, blur and jerkiness compared to the existing bitrate only calculation defined in the ITU G 1070 model. The accuracy of the proposed perceptual video quality metrics is compared against popular full reference objective methods as defined by VQEG.

  2. Assessment of shrimp farming impact on groundwater quality using analytical hierarchy process

    NASA Astrophysics Data System (ADS)

    Anggie, Bernadietta; Subiyanto, Arief, Ulfah Mediaty; Djuniadi

    2018-03-01

    Improved shrimp farming affects the groundwater quality conditions. Assessment of shrimp farming impact on groundwater quality conventionally has less accuracy. This paper presents the implementation of Analytical Hierarchy Process (AHP) method for assessing shrimp farming impact on groundwater quality. The data used is the impact data of shrimp farming in one of the regions in Indonesia from 2006-2016. Criteria used in this study were 8 criteria and divided into 49 sub-criteria. The weighting by AHP performed to determine the importance level of criteria and sub-criteria. Final priority class of shrimp farming impact were obtained from the calculation of criteria's and sub-criteria's weights. The validation was done by comparing priority class of shrimp farming impact and water quality conditions. The result show that 50% of the total area was moderate priority class, 37% was low priority class and 13% was high priority class. From the validation result impact assessment for shrimp farming has been high accuracy to the groundwater quality conditions. This study shows that assessment based on AHP has a higher accuracy to shrimp farming impact and can be used as the basic fisheries planning to deal with impacts that have been generated.

  3. Validation of Personal Digital Photography to Assess Dietary Quality among People with Intellectual Disabilities

    ERIC Educational Resources Information Center

    Elinder, L. S.; Brunosson, A.; Bergstrom, H.; Hagstromer, M.; Patterson, E.

    2012-01-01

    Background: Dietary assessment is a challenge in general, and specifically in individuals with intellectual disabilities (ID). This study aimed to evaluate personal digital photography as a method of assessing different aspects of dietary quality in this target group. Method: Eighteen adults with ID were recruited from community residences and…

  4. Quality assessment of protein model-structures based on structural and functional similarities

    PubMed Central

    2012-01-01

    Background Experimental determination of protein 3D structures is expensive, time consuming and sometimes impossible. A gap between number of protein structures deposited in the World Wide Protein Data Bank and the number of sequenced proteins constantly broadens. Computational modeling is deemed to be one of the ways to deal with the problem. Although protein 3D structure prediction is a difficult task, many tools are available. These tools can model it from a sequence or partial structural information, e.g. contact maps. Consequently, biologists have the ability to generate automatically a putative 3D structure model of any protein. However, the main issue becomes evaluation of the model quality, which is one of the most important challenges of structural biology. Results GOBA - Gene Ontology-Based Assessment is a novel Protein Model Quality Assessment Program. It estimates the compatibility between a model-structure and its expected function. GOBA is based on the assumption that a high quality model is expected to be structurally similar to proteins functionally similar to the prediction target. Whereas DALI is used to measure structure similarity, protein functional similarity is quantified using standardized and hierarchical description of proteins provided by Gene Ontology combined with Wang's algorithm for calculating semantic similarity. Two approaches are proposed to express the quality of protein model-structures. One is a single model quality assessment method, the other is its modification, which provides a relative measure of model quality. Exhaustive evaluation is performed on data sets of model-structures submitted to the CASP8 and CASP9 contests. Conclusions The validation shows that the method is able to discriminate between good and bad model-structures. The best of tested GOBA scores achieved 0.74 and 0.8 as a mean Pearson correlation to the observed quality of models in our CASP8 and CASP9-based validation sets. GOBA also obtained the best

  5. Quality assessment of protein model-structures based on structural and functional similarities.

    PubMed

    Konopka, Bogumil M; Nebel, Jean-Christophe; Kotulska, Malgorzata

    2012-09-21

    Experimental determination of protein 3D structures is expensive, time consuming and sometimes impossible. A gap between number of protein structures deposited in the World Wide Protein Data Bank and the number of sequenced proteins constantly broadens. Computational modeling is deemed to be one of the ways to deal with the problem. Although protein 3D structure prediction is a difficult task, many tools are available. These tools can model it from a sequence or partial structural information, e.g. contact maps. Consequently, biologists have the ability to generate automatically a putative 3D structure model of any protein. However, the main issue becomes evaluation of the model quality, which is one of the most important challenges of structural biology. GOBA--Gene Ontology-Based Assessment is a novel Protein Model Quality Assessment Program. It estimates the compatibility between a model-structure and its expected function. GOBA is based on the assumption that a high quality model is expected to be structurally similar to proteins functionally similar to the prediction target. Whereas DALI is used to measure structure similarity, protein functional similarity is quantified using standardized and hierarchical description of proteins provided by Gene Ontology combined with Wang's algorithm for calculating semantic similarity. Two approaches are proposed to express the quality of protein model-structures. One is a single model quality assessment method, the other is its modification, which provides a relative measure of model quality. Exhaustive evaluation is performed on data sets of model-structures submitted to the CASP8 and CASP9 contests. The validation shows that the method is able to discriminate between good and bad model-structures. The best of tested GOBA scores achieved 0.74 and 0.8 as a mean Pearson correlation to the observed quality of models in our CASP8 and CASP9-based validation sets. GOBA also obtained the best result for two targets of CASP8, and

  6. Carbon Nanotube Material Quality Assessment

    NASA Technical Reports Server (NTRS)

    Yowell, Leonard; Arepalli, Sivaram; Sosa, Edward; Niolaev, Pavel; Gorelik, Olga

    2006-01-01

    The nanomaterial activities at NASA Johnson Space Center focus on carbon nanotube production, characterization and their applications for aerospace systems. Single wall carbon nanotubes are produced by arc and laser methods. Characterization of the nanotube material is performed using the NASA JSC protocol developed by combining analytical techniques of SEM, TEM, UV-VIS-NIR absorption, Raman, and TGA. A possible addition of other techniques such as XPS, and ICP to the existing protocol will be discussed. Changes in the quality of the material collected in different regions of the arc and laser production chambers is assessed using the original JSC protocol. The observed variations indicate different growth conditions in different regions of the production chambers.

  7. Measurement of IgE antibodies using liquid allergens--an inter-method and inter-laboratory quality assessment.

    PubMed

    Aberer, Werner; Kränke, Birger

    2002-11-30

    The determination of IgE antibodies is important for the in vitro diagnosis of allergic diseases. However, not all systems currently available in the market fulfill essential quality criteria, e.g. regarding characteristics such as sensitivity and specificity, and the data do not always reflect true clinical relevance in the required fashion. Recent innovations may reduce the workload for the technician, and thus help save time and money. More importantly, they might reduce potential sources of error. Two allergy systems, the well established Pharmacia CAP system that uses the allergens conventionally in a solid phase and the ALLERgen system that employs liquid allergens, were compared with regard to quality criteria and practicability. Defined serum pools were checked for within-run and between-days imprecision of IgE antibody detection in two independent laboratories. Serum specimens from allergic patients and controls were tested in parallel using both methods for total and antigen-specific IgE antibody detection under standardized conditions. In addition, one laboratory working exclusively with the ALLERgen system participated in the Austrian inter-laboratory quality assessment program. The two systems were comparable in terms of sensitivity and specificity, and also showed good correlation. Within-run evaluations were excellent for total IgE and antigen-specific IgE, and the between-days imprecision was satisfactory. Coefficients of variation were within an acceptable range for the different groups of allergens. In the external quality control program the data obtained with the ALLERgen system showed good concordance with other systems in use; up to 94% of the results were identical when considering clinically relevant sensitizations. Regarding practicability, both systems were most satisfactory for the operator. The ALLERgen system offered a certain advantage in terms of automated operation, which resulted in shorter fixed and variable phases of personnel

  8. Assessing Quality of Pre-Service Physics Teachers' Written Arguments

    ERIC Educational Resources Information Center

    Aydeniz, Mehmet; Gürçay, Deniz

    2013-01-01

    Purpose: The purpose of this study was to assess the quality of scientific arguments developed by pre-service physics teachers. Sample: The participants were 171 pre-service physics teachers recruited from two universities: 86 from University A and 85 from University B. Design and method: Participants were prompted to develop a written argument to…

  9. Assess water scarcity integrating water quantity and quality

    NASA Astrophysics Data System (ADS)

    Liu, J.; Zeng, Z.

    2014-12-01

    Water scarcity has become widespread all over the world. Current methods for water scarcity assessment are mainly based on water quantity and seldom consider water quality. Here, we develop an approach for assessing water scarcity considering both water quantity and quality. In this approach, a new water scarcity index is used to describe the severity of water scarcity in the form of a water scarcity meter, which may help to communicate water scarcity to a wider audience. To illustrate the approach, we analyzed the historical trend of water scarcity for Beijing city in China during 1995-2009, as well as the assessment for different river basins in China. The results show that Beijing made a huge progress in mitigating water scarcity, and that from 1999 to 2009 the blue and grey water scarcity index decreased by 59% and 62%, respectively. Despite this progress, we demonstrate that Beijing is still characterized by serious water scarcity due to both water quantity and quality. The water scarcity index remained at a high value of 3.5 with a blue and grey water scarcity index of 1.2 and 2.3 in 2009 (exceeding the thresholds of 0.4 and 1, respectively). As a result of unsustainable water use and pollution, groundwater levels continue to decline, and water quality shows a continuously deteriorating trend. To curb this trend, future water policies should further decrease water withdrawal from local sources (in particular groundwater) within Beijing, and should limit the grey water footprint below the total amount of water resources.

  10. NATIONAL WATER-QUALITY ASSESSMENT (NAWQA) PROGRAM

    EPA Science Inventory

    The National Water-Quality Assessment (NAWQA) Program is designed to describe the status and trends in the quality of the Nations ground- and surface-water resources and to provide a sound understanding of the natural and human factors that affect the quality of these resources. ...

  11. Methods for the Quality Control of Inactivated Poliovirus Vaccines.

    PubMed

    Wilton, Thomas

    2016-01-01

    Inactivated poliovirus vaccine (IPV) plays an instrumental role in the Global Poliovirus Eradication Initiative (GPEI). The quality of IPV is controlled by assessment of the potency of vaccine batches. The potency of IPV can be assessed by both in vivo and in vitro methods. In vitro potency assessment is based upon the assessment of the quantity of the D-Antigen (D-Ag) units in an IPV. The D-Ag unit is used as a measure of potency as it is largely expressed on native infectious virions and is the protective immunogen. The most commonly used in vitro test is the indirect ELISA which is used to ensure consistency throughout production.A range of in vivo assays have been developed in monkeys, chicks, guinea pigs, mice, and rats to assess the potency of IPV. All are based on assessment of the neutralizing antibody titer within the sera of the respective animal model. The rat potency test has become the favored in vivo potency test as it shows minimal variation between laboratories and the antibody patterns of rats and humans are similar. With the development of transgenic mice expressing the human poliovirus receptor, immunization-challenge tests have been developed to assess the potency of IPVs. This chapter describes in detail the methodology of these three laboratory tests to assess the quality of IPVs.

  12. Multiple Image Arrangement for Subjective Quality Assessment

    NASA Astrophysics Data System (ADS)

    Wang, Yan; Zhai, Guangtao

    2017-12-01

    Subjective quality assessment serves as the foundation for almost all visual quality related researches. Size of the image quality databases has expanded from dozens to thousands in the last decades. Since each subjective rating therein has to be averaged over quite a few participants, the ever-increasing overall size of those databases calls for an evolution of existing subjective test methods. Traditional single/double stimulus based approaches are being replaced by multiple image tests, where several distorted versions of the original one are displayed and rated at once. And this naturally brings upon the question of how to arrange those multiple images on screen during the test. In this paper, we answer this question by performing subjective viewing test with eye tracker for different types arrangements. Our research indicates that isometric arrangement imposes less duress on participants and has more uniform distribution of eye fixations and movements and therefore is expected to generate more reliable subjective ratings.

  13. Standardizing Quality Assessment of Fused Remotely Sensed Images

    NASA Astrophysics Data System (ADS)

    Pohl, C.; Moellmann, J.; Fries, K.

    2017-09-01

    The multitude of available operational remote sensing satellites led to the development of many image fusion techniques to provide high spatial, spectral and temporal resolution images. The comparison of different techniques is necessary to obtain an optimized image for the different applications of remote sensing. There are two approaches in assessing image quality: 1. Quantitatively by visual interpretation and 2. Quantitatively using image quality indices. However an objective comparison is difficult due to the fact that a visual assessment is always subject and a quantitative assessment is done by different criteria. Depending on the criteria and indices the result varies. Therefore it is necessary to standardize both processes (qualitative and quantitative assessment) in order to allow an objective image fusion quality evaluation. Various studies have been conducted at the University of Osnabrueck (UOS) to establish a standardized process to objectively compare fused image quality. First established image fusion quality assessment protocols, i.e. Quality with No Reference (QNR) and Khan's protocol, were compared on varies fusion experiments. Second the process of visual quality assessment was structured and standardized with the aim to provide an evaluation protocol. This manuscript reports on the results of the comparison and provides recommendations for future research.

  14. Assessment and prediction of air quality using fuzzy logic and autoregressive models

    NASA Astrophysics Data System (ADS)

    Carbajal-Hernández, José Juan; Sánchez-Fernández, Luis P.; Carrasco-Ochoa, Jesús A.; Martínez-Trinidad, José Fco.

    2012-12-01

    In recent years, artificial intelligence methods have been used for the treatment of environmental problems. This work, presents two models for assessment and prediction of air quality. First, we develop a new computational model for air quality assessment in order to evaluate toxic compounds that can harm sensitive people in urban areas, affecting their normal activities. In this model we propose to use a Sigma operator to statistically asses air quality parameters using their historical data information and determining their negative impact in air quality based on toxicity limits, frequency average and deviations of toxicological tests. We also introduce a fuzzy inference system to perform parameter classification using a reasoning process and integrating them in an air quality index describing the pollution levels in five stages: excellent, good, regular, bad and danger, respectively. The second model proposed in this work predicts air quality concentrations using an autoregressive model, providing a predicted air quality index based on the fuzzy inference system previously developed. Using data from Mexico City Atmospheric Monitoring System, we perform a comparison among air quality indices developed for environmental agencies and similar models. Our results show that our models are an appropriate tool for assessing site pollution and for providing guidance to improve contingency actions in urban areas.

  15. Describing methods and interventions: a protocol for the systematic analysis of the perioperative quality improvement literature.

    PubMed

    Jones, Emma; Lees, Nicholas; Martin, Graham; Dixon-Woods, Mary

    2014-09-05

    Quality improvement (QI) methods are widely used in surgery in an effort to improve care, often using techniques such as Plan-Do-Study-Act cycles to implement specific interventions. Explicit definition of both the QI method and quality intervention is necessary to enable the accurate replication of effective interventions in practice, facilitate cumulative learning, reduce research waste and optimise benefits to patients. This systematic review aims to assess quality of reporting of QI methods and quality interventions in perioperative care. Studies reporting on quality interventions implemented in perioperative care settings will be identified. Searches will be conducted in the Ovid SP version of Medline, Scopus, the Cochrane Central Register of Controlled Trials, the Cochrane Effective Practice and Organisation of Care database and the related articles function of PubMed. The journal BMJ Quality will be searched separately. Search strategy terms will relate to (i) surgery, (ii) QI and (iii) evaluation methods. Explicit exclusion and inclusion criteria will be applied. Data from studies will be extracted using a data extraction form. The Template for Intervention Description and Replication (TIDieR) checklist will be used to evaluate quality of reporting, together with additional items aimed at assessing QI methods specifically. PROSPERO http://CRD42014012845.

  16. Developing a multidisciplinary robotic surgery quality assessment program.

    PubMed

    Gonsenhauser, Iahn; Abaza, Ronney; Mekhjian, Hagop; Moffatt-Bruce, Susan D

    2012-01-01

    The objective of this study was to test the feasibility of a novel quality-improvement (QI) program designed to incorporate multiple robotic surgical sub-specialties in one health care system. A robotic surgery quality assessment program was developed by The Ohio State University College of Medicine (OSUMC) in conjunction with The Ohio State University Medical Center Quality Improvement and Operations Department. A retrospective review of cases was performed using data interrogated from the OSUMC Information Warehouse from January 2007 through August 2009. Robotic surgery cases (n=2200) were assessed for operative times, length of stay (LOS), conversions, returns to surgery, readmissions and cancellations as potential quality indicators. An actionable and reproducible framework for the quality measurement and assessment of a multidisciplinary and interdepartmental robotic surgery program was successfully completed demonstrating areas for improvement opportunities. This report supports that standard quality indicators can be applied to multiple specialties within a health care system to develop a useful quality tracking and assessment tool in the highly specialized area of robotic surgery. © 2012 National Association for Healthcare Quality.

  17. Automated Assessment of the Quality of Depression Websites

    PubMed Central

    Tang, Thanh Tin; Hawking, David; Christensen, Helen

    2005-01-01

    Background Since health information on the World Wide Web is of variable quality, methods are needed to assist consumers to identify health websites containing evidence-based information. Manual assessment tools may assist consumers to evaluate the quality of sites. However, these tools are poorly validated and often impractical. There is a need to develop better consumer tools, and in particular to explore the potential of automated procedures for evaluating the quality of health information on the web. Objective This study (1) describes the development of an automated quality assessment procedure (AQA) designed to automatically rank depression websites according to their evidence-based quality; (2) evaluates the validity of the AQA relative to human rated evidence-based quality scores; and (3) compares the validity of Google PageRank and the AQA as indicators of evidence-based quality. Method The AQA was developed using a quality feedback technique and a set of training websites previously rated manually according to their concordance with statements in the Oxford University Centre for Evidence-Based Mental Health’s guidelines for treating depression. The validation phase involved 30 websites compiled from the DMOZ, Yahoo! and LookSmart Depression Directories by randomly selecting six sites from each of the Google PageRank bands of 0, 1-2, 3-4, 5-6 and 7-8. Evidence-based ratings from two independent raters (based on concordance with the Oxford guidelines) were then compared with scores derived from the automated AQA and Google algorithms. There was no overlap in the websites used in the training and validation phases of the study. Results The correlation between the AQA score and the evidence-based ratings was high and significant (r=0.85, P<.001). Addition of a quadratic component improved the fit, the combined linear and quadratic model explaining 82 percent of the variance. The correlation between Google PageRank and the evidence-based score was lower than

  18. The Quality of Medication Use in Older Adults: Methods of a Longitudinal Study

    PubMed Central

    Roth, Mary T.; Moore, Charity G.; Ivey, Jena L.; Esserman, Denise A.; Campbell, William H.; Weinberger, Morris

    2009-01-01

    Background The quality of medication use in older adults is a recurring problem of substantial concern. Efforts to both measure and improve the quality of medication use often define quality too narrowly and fall short of addressing the complexity of an older adult's medication regimen. Objective In an effort to more comprehensively define the quality of medication use in older adults, we conducted a prospective cohort study to: 1) describe the quality of medication use in community-residing older adults at baseline, examining differences between Whites and African Americans; 2) examine the effect of race on medication-related problems[mtr1], and 3) assess the change in quality medication use between Whites and African Americans over time. This paper presents the research design and methods of this longitudinal study. Methods We interviewed 100 White and 100 African-American community-residing older adults three times over one year (baseline, 6, and 12 months). We oversampled African Americans so that we could estimate racial differences in the quality of medication use. We collected information on the quality of medication use, relying on a clinical pharmacist's assessment of quality and the Assessing Care of Vulnerable Elders (ACOVE) quality indicators. We also collected data on demographic characteristics, health literacy, functional status, and participant-reported drug therapy concerns. Results Two hundred older adults were enrolled into the study and completed a baseline visit. Of the 200, 92% completed the 6-month visit (n=183) and 88% completed the 12-month visit (n=176). We present baseline demographic characteristics for the 200 older adults enrolled in the study. Conclusion This longitudinal study is an initial step toward developing more comprehensive, patient-centered measures and interventions to improve the quality of medication use in older adults. PMID:19028378

  19. Current challenges in bioequivalence, quality, and novel assessment technologies for topical products.

    PubMed

    Yacobi, Avraham; Shah, Vinod P; Bashaw, Edward D; Benfeldt, Eva; Davit, Barbara; Ganes, Derek; Ghosh, Tapash; Kanfer, Isadore; Kasting, Gerald B; Katz, Lindsey; Lionberger, Robert; Lu, Guang Wei; Maibach, Howard I; Pershing, Lynn K; Rackley, Russell J; Raw, Andre; Shukla, Chinmay G; Thakker, Kailas; Wagner, Nathalie; Zovko, Elizabeta; Lane, Majella E

    2014-04-01

    This paper summarises the proceedings of a recent workshop which brought together pharmaceutical scientists and dermatologists from academia, industry and regulatory agencies to discuss current regulatory issues and industry practices for establishing therapeutic bioequivalence (BE) of dermatologic topical products. The methods currently available for assessment of BE were reviewed as well as alternatives and the advantages and disadvantages of each method were considered. Guidance on quality and performance of topical products was reviewed and a framework to categorise existing and alternative methods for evaluation of BE was discussed. The outcome of the workshop emphasized both a need for greater attention to quality, possibly, via a Quality-By-Design (QBD) approach and a need to develop a "whole toolkit" approach towards the problem of determination of rate and extent in the assessment of topical bioavailability. The discussion on the BE and clinical equivalence of topical products revealed considerable concerns about the variability present in the current methodologies utilized by the industry and regulatory agencies. It was proposed that academicians, researchers, the pharmaceutical industry and regulators work together to evaluate and validate alternative methods that are based on both the underlying science and are adapted to the drug product itself instead of single "universal" method.

  20. Institutional Consequences of Quality Assessment

    ERIC Educational Resources Information Center

    Joao Rosa, Maria; Tavares, Diana; Amaral, Alberto

    2006-01-01

    This paper analyses the opinions of Portuguese university rectors and academics on the quality assessment system and its consequences at the institutional level. The results obtained show that university staff (rectors and academics, with more of the former than the latter) held optimistic views of the positive consequences of quality assessment…

  1. Maximising Confidence in Assessment Decision-Making: A Springboard to Quality in Assessment.

    ERIC Educational Resources Information Center

    Clayton, Berwyn; Booth, Robin; Roy, Sue

    The introduction of training packages has focused attention on the quality of assessment in the Australian vocational education and training (VET) sector on the quality of assessment. For the process of mutual recognition under the Australian Recognition Framework (ARF) to work effectively, there needs to be confidence in assessment decisions made…

  2. Assessing Data Quality in Emergent Domains of Earth Sciences

    NASA Astrophysics Data System (ADS)

    Darch, P. T.; Borgman, C.

    2016-12-01

    As earth scientists seek to study known phenomena in new ways, and to study new phenomena, they often develop new technologies and new methods such as embedded network sensing, or reapply extant technologies, such as seafloor drilling. Emergent domains are often highly multidisciplinary as researchers from many backgrounds converge on new research questions. They may adapt existing methods, or develop methods de novo. As a result, emerging domains tend to be methodologically heterogeneous. As these domains mature, pressure to standardize methods increases. Standardization promotes trust, reliability, accuracy, and reproducibility, and simplifies data management. However, for standardization to occur, researchers must be able to assess which of the competing methods produces the highest quality data. The exploratory nature of emerging domains discourages standardization. Because competing methods originate in different disciplinary backgrounds, their scientific credibility is difficult to compare. Instead of direct comparison, researchers attempt to conduct meta-analyses. Scientists compare datasets produced by different methods to assess their consistency and efficiency. This paper presents findings from a long-term qualitative case study of research on the deep subseafloor biosphere, an emergent domain. A diverse community converged on the study of microbes in the seafloor and those microbes' interactions with the physical environments they inhabit. Data on this problem are scarce, leading to calls for standardization as a means to acquire and analyze greater volumes of data. Lacking consistent methods, scientists attempted to conduct meta-analyses to determine the most promising methods on which to standardize. Among the factors that inhibited meta-analyses were disparate approaches to metadata and to curating data. Datasets may be deposited in a variety of databases or kept on individual scientists' servers. Associated metadata may be inconsistent or hard to

  3. Forensic mental health assessment in France: recommendations for quality improvement.

    PubMed

    Combalbert, Nicolas; Andronikof, Anne; Armand, Marine; Robin, Cécile; Bazex, Hélène

    2014-01-01

    The quality of forensic mental health assessment has been a growing concern in various countries on both sides of the Atlantic, but the legal systems are not always comparable and some aspects of forensic assessment are specific to a given country. This paper describes the legal context of forensic psychological assessment in France (i.e. pre-trial investigation phase entrusted to a judge, with mental health assessment performed by preselected professionals called "experts" in French), its advantages and its pitfalls. Forensic psychiatric or psychological assessment is often an essential and decisive element in criminal cases, but since a judiciary scandal which was made public in 2005 (the Outreau case) there has been increasing criticism from the public and the legal profession regarding the reliability of clinical conclusions. Several academic studies and a parliamentary report have highlighted various faulty aspects in both the judiciary process and the mental health assessments. The heterogeneity of expert practices in France appears to be mainly related to a lack of consensus on several core notions such as mental health diagnosis or assessment methods, poor working conditions, lack of specialized training, and insufficient familiarity with the Code of Ethics. In this article we describe and analyze the French practice of forensic psychologists and psychiatrists in criminal cases and propose steps that could be taken to improve its quality, such as setting up specialized training courses, enforcing the Code of Ethics for psychologists, and calling for consensus on diagnostic and assessment methods. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Assessment of eco-environmental quality of Western Taiwan Straits Economic Zone.

    PubMed

    Ma, He; Shi, Longyu

    2016-05-01

    Regional eco-environmental quality is the key and foundation to the sustainable socio-economic development of a region. Eco-environmental quality assessment can reveal the capacity of sustainable socio-economic development in a region and the degree of coordination between social production and the living environment. As part of a new development strategy for Fujian Province, the Western Taiwan Straits Economic Zone (hereafter referred to as the Economic Zone) provides an important guarantee for the development of China's southeastern coastal area. Based on ecological and remote sensing data on the Economic Zone obtained in 2000, 2005, and 2010, this study investigated county-level administrative regions with a comprehensive index of eco-environmental indicators. An objective weighting method was used to determine the importance of each indicator. This led to the development of an indicator system to assess the eco-environmental quality of the economic zone. ArcGIS software was used to assess the eco-environmental quality of the economic zone based on each indicator. The eco-environmental quality index (EQI) of the county-level administrative regions was calculated. The overall eco-environmental quality of the Economic Zone during the period studied is described and analyzed. The results show that the overall eco-environmental quality of the Economic Zone is satisfactory, but significant intraregional differences still exist. The key to improving the overall eco-environmental quality of this area is to restore vegetation and preserve biodiversity.

  5. Measuring and Improving the Quality of Preprocedural Assessments.

    PubMed

    Manji, Farah; McCarty, Kelsey; Kurzweil, Vanessa; Mark, Eden; Rathmell, James P; Agarwala, Aalok V

    2017-06-01

    testing clinic or phone program (P < .0001). The most common reason given for "unsatisfactory" ratings was a perception of "missing information" (49.2%). Chart reviews revealed that inadequate documentation was in reality the most common deficiency in preprocedural evaluations (35 of 67 reviews, 52.2%). The overwhelming majority of preprocedural assessments performed at our institution were considered satisfactory or exemplary by day-of-surgery anesthesia providers. This was demonstrated by both the case-by-case ratings and midpoint survey. However, the perceived frequency of "unsatisfactory" evaluations was worse when providers were asked to reflect on the quality of preprocedural evaluations generally versus rate them individually. Analysis of comments left by providers allowed us to identify specific and actionable areas for improvement. This method can be used by other institutions to identify systemic deficiencies in the preprocedural evaluation process.

  6. Groundwater quality data from the National Water-Quality Assessment Project, May 2012 through December 2013

    USGS Publications Warehouse

    Arnold, Terri L.; Desimone, Leslie A.; Bexfield, Laura M.; Lindsey, Bruce D.; Barlow, Jeannie R.; Kulongoski, Justin T.; Musgrove, MaryLynn; Kingsbury, James A.; Belitz, Kenneth

    2016-06-20

    Groundwater-quality data were collected from 748 wells as part of the National Water-Quality Assessment Project of the U.S. Geological Survey National Water-Quality Program from May 2012 through December 2013. The data were collected from four types of well networks: principal aquifer study networks, which assess the quality of groundwater used for public water supply; land-use study networks, which assess land-use effects on shallow groundwater quality; major aquifer study networks, which assess the quality of groundwater used for domestic supply; and enhanced trends networks, which evaluate the time scales during which groundwater quality changes. Groundwater samples were analyzed for a large number of water-quality indicators and constituents, including major ions, nutrients, trace elements, volatile organic compounds, pesticides, and radionuclides. These groundwater quality data are tabulated in this report. Quality-control samples also were collected; data from blank and replicate quality-control samples are included in this report.

  7. Competency in health care management: a training model in epidemiologic methods for assessing and improving the quality of clinical practice through evidence-based decision making.

    PubMed

    Hudak, R P; Jacoby, I; Meyer, G S; Potter, A L; Hooper, T I; Krakauer, H

    1997-01-01

    This article describes a training model that focuses on health care management by applying epidemiologic methods to assess and improve the quality of clinical practice. The model's uniqueness is its focus on integrating clinical evidence-based decision making with fundamental principles of resource management to achieve attainable, cost-effective, high-quality health outcomes. The target students are current and prospective clinical and administrative executives who must optimize decision making at the clinical and managerial levels of health care organizations.

  8. Structured implicit review: a new method for monitoring nursing care quality.

    PubMed

    Pearson, M L; Lee, J L; Chang, B L; Elliott, M; Kahn, K L; Rubenstein, L V

    2000-11-01

    Nurses' independent decisions about assessment, treatment, and nursing interventions for hospitalized patients are important determinants of quality of care. Physician peer implicit review of medical records has been central to Medicare quality management and is considered the gold standard for reviewing physician care, but peer implicit review of nursing processes of care has not received similar attention. The objective of this study was to develop and evaluate nurse structured implicit review (SIR) methods. We developed SIR instruments for rating the quality of inpatient nursing care for congestive heart failure (CHF) and cerebrovascular accident (CVA). Nurse reviewers used the SIR form to rate a nationally representative sample of randomly selected medical records for each disease from 297 acute care hospitals in 5 states (collected by the RAND-HCFA Prospective Payment System study). The study subjects were elderly Medicare inpatients with CHF (n = 291) or CVA (n = 283). We developed and tested scales reflecting domains of nursing process, evaluated interrater and interitem reliability, and assessed the extent to which items and scales predicted overall ratings of the quality of nursing care. Interrater reliability for 14 of 16 scales (CHF) or 10 of 16 scales (CVA) was > or = 0.40. Interitem reliability was > 0.80 for all but 1 scale (both diseases). Functional Assessment, Physical Assessment, and Medication Tracking ratings were the strongest predictors of overall nursing quality ratings (P < 0.001 for each). Nurse peer review with SIR has adequate interrater and excellent scale reliabilities and can be a valuable tool for assessing nurse performance.

  9. Assessing Assessment Quality: Criteria for Quality Assurance in Design of (Peer) Assessment for Learning--A Review of Research Studies

    ERIC Educational Resources Information Center

    Tillema, Harm; Leenknecht, Martijn; Segers, Mien

    2011-01-01

    The interest in "assessment for learning" (AfL) has resulted in a search for new modes of assessment that are better aligned to students' learning how to learn. However, with the introduction of new assessment tools, also questions arose with respect to the quality of its measurement. On the one hand, the appropriateness of traditional,…

  10. Exploring Rating Quality in Rater-Mediated Assessments Using Mokken Scale Analysis

    PubMed Central

    Wind, Stefanie A.; Engelhard, George

    2015-01-01

    Mokken scale analysis is a probabilistic nonparametric approach that offers statistical and graphical tools for evaluating the quality of social science measurement without placing potentially inappropriate restrictions on the structure of a data set. In particular, Mokken scaling provides a useful method for evaluating important measurement properties, such as invariance, in contexts where response processes are not well understood. Because rater-mediated assessments involve complex interactions among many variables, including assessment contexts, student artifacts, rubrics, individual rater characteristics, and others, rater-assigned scores are suitable candidates for Mokken scale analysis. The purposes of this study are to describe a suite of indices that can be used to explore the psychometric quality of data from rater-mediated assessments and to illustrate the substantive interpretation of Mokken-based statistics and displays in this context. Techniques that are commonly used in polytomous applications of Mokken scaling are adapted for use with rater-mediated assessments, with a focus on the substantive interpretation related to individual raters. Overall, the findings suggest that indices of rater monotonicity, rater scalability, and invariant rater ordering based on Mokken scaling provide diagnostic information at the level of individual raters related to the requirements for invariant measurement. These Mokken-based indices serve as an additional suite of diagnostic tools for exploring the quality of data from rater-mediated assessments that can supplement rating quality indices based on parametric models. PMID:29795883

  11. Assessing Quality in Home Visiting Programs

    ERIC Educational Resources Information Center

    Korfmacher, Jon; Laszewski, Audrey; Sparr, Mariel; Hammel, Jennifer

    2013-01-01

    Defining quality and designing a quality assessment measure for home visitation programs is a complex and multifaceted undertaking. This article summarizes the process used to create the Home Visitation Program Quality Rating Tool (HVPQRT) and identifies next steps for its development. The HVPQRT measures both structural and dynamic features of…

  12. Indices for the assessment of nutritional quality of meals: a systematic review.

    PubMed

    Gorgulho, B M; Pot, G K; Sarti, F M; Marchioni, D M

    2016-06-01

    This systematic review aimed to synthesise information on indices developed to evaluate nutritional quality of meals. A strategy for systematic search of the literature was developed using keywords related to assessment of meal quality. Databases searched included ScienceDirect, PubMed, Lilacs, SciELO, Scopus, Cochrane, Embase and Google Scholar. The literature search resulted in seven different meal quality indices. Each article was analysed in order to identify the following items: authors, country, year, study design, population characteristics, type of meal evaluated, dietary assessment method, characteristics evaluated (nutrients or food items), score range, index components, nutritional references, correlations performed, validation and relationship with an outcome (if existing). Two studies developed instruments to assess the quality of breakfast, three analysed lunch, one evaluated dinner and one was applied to all types of meals and snacks. All meal quality indices reviewed were based on the evaluation of presence or absence of food groups and relative contributions of nutrients, according to food-based guidelines or nutrient references, adapting the daily dietary recommendations to one specific meal. Most of the indices included three items as components for meal quality assessment: (I) total fat or some specific type of fat, (II) fruits and vegetables and (III) cereals or whole grains. This systematic review indicates aspects that need further research, particularly the numerous approaches to assessing meals considering different foods and nutrients, and the need for validation studies of meal indices.

  13. Water Quality Assessment in the Vouga Catchment (Portugal) through the Integration of Hydrologic Modeling, Economic Valuation, and Optimization Methods

    NASA Astrophysics Data System (ADS)

    Hawtree, Daniel; Julich, Stefan; Rocha, João; Roebeling, Peter; Feger, Karl-Heinz

    2016-04-01

    Hydrologic model assessments of the impacts of land-cover / use change (LCLUC) are fundamental for the development of catchment management plans, which are increasingly needed for meeting water quality standards (i.e. Water Framework Directive). These assessments can be difficult to conduct at the spatial scale required for such plans, due to data limitations and the challenge of up-scaling from field / small scale studies to larger regions. Furthermore, such hydrologic assessments are of limited practical use if the financial impacts of any potential land-cover / management changes on local stakeholders are adequately quantified and taken into planning consideration. To address these challenges, this study presents an approach that integrates hydrologic modeling, economic valuation, and landscape optimization methods. This approach is applied to the Vouga catchment, a large (2,298 km^2) mixed land-use catchment in north-central Portugal. The Vouga has high nutrient (nitrogen and phosphorus) impacts in a number of reaches, which have negative impacts on downstream wetlands and groundwater supplies. To examine potential improvements to water quality, the Soil and Water Assessment Tool (SWAT) was calibrated over a five period (2002 - 2007) to establish the baseline hydrologic and nutrient fluxes. This calibration relies upon the up-scaling of findings from previous field studies (on vegetation and soils), hydrologic assessments, and modeling studies. The agricultural income for local stakeholders was estimated from existing land-cover and management approaches is made, to establish the baseline financial conditions. An optimization algorithm is then applied to the baseline scenario using both the biophysical and financial information, which seeks to determine various (most) optimal states. The preliminary results from this work are presented, and the advantages and challenges of using such an approach for scenario analysis for catchment management are discussed

  14. Assessment of visual landscape quality using IKONOS imagery.

    PubMed

    Ozkan, Ulas Yunus

    2014-07-01

    The assessment of visual landscape quality is of importance to the management of urban woodlands. Satellite remote sensing may be used for this purpose as a substitute for traditional survey techniques that are both labour-intensive and time-consuming. This study examines the association between the quality of the perceived visual landscape in urban woodlands and texture measures extracted from IKONOS satellite data, which features 4-m spatial resolution and four spectral bands. The study was conducted in the woodlands of Istanbul (the most important element of urban mosaic) lying along both shores of the Bosporus Strait. The visual quality assessment applied in this study is based on the perceptual approach and was performed via a survey of expressed preferences. For this purpose, representative photographs of real scenery were used to elicit observers' preferences. A slide show comprising 33 images was presented to a group of 153 volunteers (all undergraduate students), and they were asked to rate the visual quality of each on a 10-point scale (1 for very low visual quality, 10 for very high). Average visual quality scores were calculated for landscape. Texture measures were acquired using the two methods: pixel-based and object-based. Pixel-based texture measures were extracted from the first principle component (PC1) image. Object-based texture measures were extracted by using the original four bands. The association between image texture measures and perceived visual landscape quality was tested via Pearson's correlation coefficient. The analysis found a strong linear association between image texture measures and visual quality. The highest correlation coefficient was calculated between standard deviation of gray levels (SDGL) (one of the pixel-based texture measures) and visual quality (r = 0.82, P < 0.05). The results showed that perceived visual quality of urban woodland landscapes can be estimated by using texture measures extracted from satellite

  15. QUAST: quality assessment tool for genome assemblies.

    PubMed

    Gurevich, Alexey; Saveliev, Vladislav; Vyahhi, Nikolay; Tesler, Glenn

    2013-04-15

    Limitations of genome sequencing techniques have led to dozens of assembly algorithms, none of which is perfect. A number of methods for comparing assemblers have been developed, but none is yet a recognized benchmark. Further, most existing methods for comparing assemblies are only applicable to new assemblies of finished genomes; the problem of evaluating assemblies of previously unsequenced species has not been adequately considered. Here, we present QUAST-a quality assessment tool for evaluating and comparing genome assemblies. This tool improves on leading assembly comparison software with new ideas and quality metrics. QUAST can evaluate assemblies both with a reference genome, as well as without a reference. QUAST produces many reports, summary tables and plots to help scientists in their research and in their publications. In this study, we used QUAST to compare several genome assemblers on three datasets. QUAST tables and plots for all of them are available in the Supplementary Material, and interactive versions of these reports are on the QUAST website. http://bioinf.spbau.ru/quast . Supplementary data are available at Bioinformatics online.

  16. Methods for assessing pre-induction cervical ripening

    PubMed Central

    Ezebialu, Ifeanyichukwu U; Eke, Ahizechukwu C; Eleje, George U; Nwachukwu, Chukwuemeka E

    2015-01-01

    Background Induction of labour is the artificial initiation of labour in a pregnant woman after the age of fetal viability but without any objective evidence of active phase labour and with intact fetal membranes. The need for induction of labour may arise due to a problem in the mother, her fetus or both, and the procedure may be carried out at or before term. Obstetricians have long known that for this to be successful, it is important that the uterine cervix (the neck of the womb) has favourable characteristics in terms of readiness to go into the labour state. Objectives To compare Bishop score with any other method for assessing pre-induction cervical ripening in women admitted for induction of labour. Search methods We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (31 March 2015) and reference lists of retrieved studies to identify randomised controlled trials (RCTs). Selection criteria All RCTs comparing Bishop score with any other methods of pre-induction cervical assessment in women admitted for induction of labour. Cluster-RCTs were eligible for inclusion but none were identified. Quasi-RCTs and studies using a cross-over design were not eligible for inclusion. Studies published in abstract form were eligible for inclusion if they provided sufficient information. Comparisons could include the following. Bishop score versus transvaginal ultrasound (TVUS). Bishop score versus Insulin-like growth factor binding protein-1 (IGFBP-1). Bishop score versus vaginal fetal fibronectin (fFN). However, we only identified data for a comparison of Bishop score versus TVUS. Data collection and analysis Two review authors independently assessed the trials for inclusion, extracted the data and assessed trial quality. Data were checked for accuracy. Main results We included two trials that recruited a total of 234 women. The overall risk of bias was low for the two studies. Both studies compared Bishop score withTVUS. The two included studies did

  17. 42 CFR 493.1299 - Standard: Postanalytic systems quality assessment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Postanalytic systems quality assessment... Nonwaived Testing Postanalytic Systems § 493.1299 Standard: Postanalytic systems quality assessment. (a) The....1291. (b) The postanalytic systems quality assessment must include a review of the effectiveness of...

  18. Assessing the Assessment Methods: Climate Change and Hydrologic Impacts

    NASA Astrophysics Data System (ADS)

    Brekke, L. D.; Clark, M. P.; Gutmann, E. D.; Mizukami, N.; Mendoza, P. A.; Rasmussen, R.; Ikeda, K.; Pruitt, T.; Arnold, J. R.; Rajagopalan, B.

    2014-12-01

    The Bureau of Reclamation, the U.S. Army Corps of Engineers, and other water management agencies have an interest in developing reliable, science-based methods for incorporating climate change information into longer-term water resources planning. Such assessments must quantify projections of future climate and hydrology, typically relying on some form of spatial downscaling and bias correction to produce watershed-scale weather information that subsequently drives hydrology and other water resource management analyses (e.g., water demands, water quality, and environmental habitat). Water agencies continue to face challenging method decisions in these endeavors: (1) which downscaling method should be applied and at what resolution; (2) what observational dataset should be used to drive downscaling and hydrologic analysis; (3) what hydrologic model(s) should be used and how should these models be configured and calibrated? There is a critical need to understand the ramification of these method decisions, as they affect the signal and uncertainties produced by climate change assessments and, thus, adaptation planning. This presentation summarizes results from a three-year effort to identify strengths and weaknesses of widely applied methods for downscaling climate projections and assessing hydrologic conditions. Methods were evaluated from two perspectives: historical fidelity, and tendency to modulate a global climate model's climate change signal. On downscaling, four methods were applied at multiple resolutions: statistically using Bias Correction Spatial Disaggregation, Bias Correction Constructed Analogs, and Asynchronous Regression; dynamically using the Weather Research and Forecasting model. Downscaling results were then used to drive hydrologic analyses over the contiguous U.S. using multiple models (VIC, CLM, PRMS), with added focus placed on case study basins within the Colorado Headwaters. The presentation will identify which types of climate changes are

  19. No-reference image quality assessment based on statistics of convolution feature maps

    NASA Astrophysics Data System (ADS)

    Lv, Xiaoxin; Qin, Min; Chen, Xiaohui; Wei, Guo

    2018-04-01

    We propose a Convolutional Feature Maps (CFM) driven approach to accurately predict image quality. Our motivation bases on the finding that the Nature Scene Statistic (NSS) features on convolution feature maps are significantly sensitive to distortion degree of an image. In our method, a Convolutional Neural Network (CNN) is trained to obtain kernels for generating CFM. We design a forward NSS layer which performs on CFM to better extract NSS features. The quality aware features derived from the output of NSS layer is effective to describe the distortion type and degree an image suffered. Finally, a Support Vector Regression (SVR) is employed in our No-Reference Image Quality Assessment (NR-IQA) model to predict a subjective quality score of a distorted image. Experiments conducted on two public databases demonstrate the promising performance of the proposed method is competitive to state of the art NR-IQA methods.

  20. Quality Assessment in Oncology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Albert, Jeffrey M.; Das, Prajnan, E-mail: prajdas@mdanderson.org

    2012-07-01

    The movement to improve healthcare quality has led to a need for carefully designed quality indicators that accurately reflect the quality of care. Many different measures have been proposed and continue to be developed by governmental agencies and accrediting bodies. However, given the inherent differences in the delivery of care among medical specialties, the same indicators will not be valid across all of them. Specifically, oncology is a field in which it can be difficult to develop quality indicators, because the effectiveness of an oncologic intervention is often not immediately apparent, and the multidisciplinary nature of the field necessarily involvesmore » many different specialties. Existing and emerging comparative effectiveness data are helping to guide evidence-based practice, and the increasing availability of these data provides the opportunity to identify key structure and process measures that predict for quality outcomes. The increasing emphasis on quality and efficiency will continue to compel the medical profession to identify appropriate quality measures to facilitate quality improvement efforts and to guide accreditation, credentialing, and reimbursement. Given the wide-reaching implications of quality metrics, it is essential that they be developed and implemented with scientific rigor. The aims of the present report were to review the current state of quality assessment in oncology, identify existing indicators with the best evidence to support their implementation, and propose a framework for identifying and refining measures most indicative of true quality in oncologic care.« less

  1. 42 CFR 493.1289 - Standard: Analytic systems quality assessment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Analytic systems quality assessment. 493... Nonwaived Testing Analytic Systems § 493.1289 Standard: Analytic systems quality assessment. (a) The... through 493.1283. (b) The analytic systems quality assessment must include a review of the effectiveness...

  2. 42 CFR 493.1249 - Standard: Preanalytic systems quality assessment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Preanalytic systems quality assessment... Nonwaived Testing Preanalytic Systems § 493.1249 Standard: Preanalytic systems quality assessment. (a) The....1241 through 493.1242. (b) The preanalytic systems quality assessment must include a review of the...

  3. Assessing quality in volcanic ash soils

    Treesearch

    Terry L. Craigg; Steven W. Howes

    2007-01-01

    Forest managers must understand how changes in soil quality resulting from project implementation affect long-term productivity and watershed health. Volcanic ash soils have unique properties that affect their quality and function; and which may warrant soil quality standards and assessment techniques that are different from other soils. We discuss the concept of soil...

  4. A checklist to assess the quality of reports on spa therapy and balneotherapy trials was developed using the Delphi consensus method: the SPAC checklist.

    PubMed

    Kamioka, Hiroharu; Kawamura, Yoichi; Tsutani, Kiichiro; Maeda, Masaharu; Hayasaka, Shinya; Okuizum, Hiroyasu; Okada, Shinpei; Honda, Takuya; Iijima, Yuichi

    2013-08-01

    The purpose of this study was to develop a checklist of items that describes and measures the quality of reports of interventional trials assessing spa therapy. The Delphi consensus method was used to select the number of items in the checklist. A total of eight individuals participated, including an epidemiologist, a clinical research methodologist, clinical researchers, a medical journalist, and a health fitness programmer. Participants ranked on a 9-point Likert scale whether an item should be included in the checklist. Three rounds of the Delphi method were conducted to achieve consensus. The final checklist contained 19 items, with items related to title, place of implementation (specificity of spa), care provider influence, and additional measures to minimize the potential bias from withdrawals, loss to follow-up, and low treatment adherence. This checklist is simple and quick to complete, and should help clinicians and researchers critically appraise the medical and healthcare literature, reviewers assess the quality of reports included in systematic reviews, and researchers plan interventional trials of spa therapy. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Comparison of national mental health quality assessment programs across the globe.

    PubMed

    Parameswaran, Sharat; Spaeth-Rublee, Brigitta; Huynh, Phuong Trang; Pincus, Harold Alan

    2012-10-01

    This study by the International Initiative for Mental Health Leadership Clinical Leaders Project sought to describe ongoing or soon-to-be-established national-level mental health quality measurement programs in 12 participating countries, in order to understand the nature and structure of these programs. A survey was distributed to representatives from the participating countries (Australia, Canada, England, Germany, Ireland, Japan, the Netherlands, New Zealand, Norway, Scotland, Taiwan, and the United States). Data included descriptions of qualifying programs and the organizations responsible for them, quality indicators used, entities assessed, sources and means of the programs' data collection, the level at which data are reported, and how the data are used. Participants were asked to identify which quality domains and subdomains were represented by indicators in each program. Results were analyzed with descriptive statistics. Thirty-eight programs were identified. Most programs were administered by governmental organizations, focused on hospital care, and used encounter or utilization databases as sources of information. Programs used different methods to identify indicators. Program data were used for various purposes. A wide range of domains of quality were represented in the programs reported, although most commonality was seen in domains associated with high-acuity care, with fewer programs assessing recovery-related domains. This study found wide variation among established quality assessment programs, which may reflect a focus on local priorities. The goal of this project is to work toward establishing an international framework for mental health quality assessment and thus a means to compare key measures of performance across countries.

  6. Assessing the Quality of Teachers' Teaching Practices

    ERIC Educational Resources Information Center

    Chen, Weiyun; Mason, Stephen; Staniszewski, Christina; Upton, Ashley; Valley, Megan

    2012-01-01

    This study assessed the extent to which nine elementary physical education teachers implemented the quality of teaching practices. Thirty physical education lessons taught by the nine teachers to their students in grades K-5 were videotaped. Four investigators coded the taped lessons using the Assessing Quality Teaching Rubric (AQTR) designed and…

  7. The Midwest Stream Quality Assessment

    USGS Publications Warehouse

    ,

    2012-01-01

    In 2013, the U.S. Geological Survey (USGS) National Water-Quality Assessment Program (NAWQA) and USGS Columbia Environmental Research Center (CERC) will be collaborating with the U.S. Environmental Protection Agency (EPA) National Rivers and Streams Assessment (NRSA) to assess stream quality across the Midwestern United States. The sites selected for this study are a subset of the larger NRSA, implemented by the EPA, States and Tribes to sample flowing waters across the United States (http://water.epa.gov/type/rsl/monitoring/riverssurvey/index.cfm). The goals are to characterize water-quality stressors—contaminants, nutrients, and sediment—and ecological conditions in streams throughout the Midwest and to determine the relative effects of these stressors on aquatic organisms in the streams. Findings will contribute useful information for communities and policymakers by identifying which human and environmental factors are the most critical in controlling stream quality. This collaborative study enhances information provided to the public and policymakers and minimizes costs by leveraging and sharing data gathered under existing programs. In the spring and early summer, NAWQA will sample streams weekly for contaminants, nutrients, and sediment. During the same time period, CERC will test sediment and water samples for toxicity, deploy time-integrating samplers, and measure reproductive effects and biomarkers of contaminant exposure in fish or amphibians. NRSA will sample sites once during the summer to assess ecological and habitat conditions in the streams by collecting data on algal, macroinvertebrate, and fish communities and collecting detailed physical-habitat measurements. Study-team members from all three programs will work in collaboration with USGS Water Science Centers and State agencies on study design, execution of sampling and analysis, and reporting.

  8. Methodological quality of meta-analyses on treatments for chronic obstructive pulmonary disease: a cross-sectional study using the AMSTAR (Assessing the Methodological Quality of Systematic Reviews) tool.

    PubMed

    Ho, Robin S T; Wu, Xinyin; Yuan, Jinqiu; Liu, Siya; Lai, Xin; Wong, Samuel Y S; Chung, Vincent C H

    2015-01-08

    Meta-analysis (MA) of randomised trials is considered to be one of the best approaches for summarising high-quality evidence on the efficacy and safety of treatments. However, methodological flaws in MAs can reduce the validity of conclusions, subsequently impairing the quality of decision making. To assess the methodological quality of MAs on COPD treatments. A cross-sectional study on MAs of COPD trials. MAs published during 2000-2013 were sampled from the Cochrane Database of Systematic Reviews and Database of Abstracts of Reviews of Effect. Methodological quality was assessed using the validated AMSTAR (Assessing the Methodological Quality of Systematic Reviews) tool. Seventy-nine MAs were sampled. Only 18% considered the scientific quality of primary studies when formulating conclusions and 49% used appropriate meta-analytic methods to combine findings. The problems were particularly acute among MAs on pharmacological treatments. In 48% of MAs the authors did not report conflict of interest. Fifty-eight percent reported harmful effects of treatment. Publication bias was not assessed in 65% of MAs, and only 10% had searched non-English databases. The methodological quality of the included MAs was disappointing. Consideration of scientific quality when formulating conclusions should be made explicit. Future MAs should improve on reporting conflict of interest and harm, assessment of publication bias, prevention of language bias and use of appropriate meta-analytic methods.

  9. Applicability of ambient toxicity testing to national or regional water-quality assessment

    USGS Publications Warehouse

    Elder, John F.

    1990-01-01

    Comprehensive assessment of the quality of natural waters requires a multifaceted approach. Descriptions of existing conditions may be achieved by various kinds of chemical and hydrologic analyses, whereas information about the effects of such conditions on living organisms depends on biological monitoring. Toxicity testing is one type of biological monitoring that can be used to identify possible effects of toxic contaminants. Based on experimentation designed to monitor responses of organisms to environmental stresses, toxicity testing may have diverse purposes in water-quality assessments. These purposes may include identification of areas that warrant further study because of poor water quality or unusual ecological features, verification of other types of monitoring, or assessment of contaminant effects on aquatic communities. Toxicity-test results are most effective when used as a complement to chemical analyses, hydrologic measurements, and other biological monitoring. However, all toxicity-testing procedures have certain limitations that must be considered in developing the methodology and applications of toxicity testing in any large-scale water-quality-assessment program. A wide variety of toxicity-test methods have been developed to fulfill the needs of diverse applications. The methods differ primarily in the selections made relative to four characteristics: (1) test species, (2) endpoint (acute or chronic), (3) test-enclosure type, and (4) test substance (toxicant) that functions as the environmental stress. Toxicity-test approaches vary in their capacity to meet the needs of large-scale assessments of existing water quality. Ambient testing, whereby the test organism is exposed to naturally occurring substances that contain toxicant mixtures in an organic or inorganic matrix, is more likely to meet these needs than are procedures that call for exposure of the test organisms to known concentrations of a single toxicant. However, meaningful

  10. Assessing Pre-Service Teachers' Quality Teaching Practices

    ERIC Educational Resources Information Center

    Chen, Weiyun; Hendricks, Kristin; Archibald, Kelsi

    2011-01-01

    The purpose of this study was to design and validate the Assessing Quality Teaching Rubrics (AQTR) that assesses the pre-service teachers' quality teaching practices in a live lesson or a videotaped lesson. Twenty-one lessons taught by 13 Physical Education Teacher Education (PETE) students were videotaped. The videotaped lessons were evaluated…

  11. Quality and readability assessment of websites related to recurrent respiratory papillomatosis

    PubMed Central

    de Groot, Olivier S.D.; Dikkers, Frederik G.

    2017-01-01

    Objective Recurrent respiratory papillomatosis (RRP) is a rare disease for which a limited number of information sources for patients exist. The role of the Internet in the patient–physician relationship is increasing. More and more patients search for online health information, which should be of good quality and easy readable. The study aim was to investigate the quality and readability of English online health information about RRP. Study Design Quality and readability assessment of online information. Methods Relevant information was collected using three different search engines and seven different search terms. Quality was assessed with the DISCERN instrument. The Flesch Reading Ease Score (FRES) and average grade level (AGL) were determined to measure readability of the English websites. Results Fifty‐one English websites were included. The mean DISCERN score of the websites is 28.1 ± 9.7 (poor quality); the mean FRES is 41.3 ± 14.9 (difficult to read); and the mean AGL is 12.6 ± 2.3. Conclusion The quality and readability of English websites about RRP is alarmingly poor. Level of Evidence NA. Laryngoscope, 127:2293–2297, 2017 PMID:28233911

  12. Application of a new integrated sediment quality assessment method to Huelva estuary and its littoral of influence (Southwestern Spain).

    PubMed

    Rosado, Daniel; Usero, José; Morillo, José

    2015-09-15

    A new integrated sediment quality assessment method composed of several assays (particle size profile, total metal content, protease K extraction, total organic carbon, toxicity bioassay with Photobacterium phosphoreum and macrobenthic community alteration) that provides a single result, the environmental degradation index (EDI), has been developed. The new method was tested on the Huelva estuary (southwest of Spain), a highly polluted area where metals dissolved in the water of the Tinto and Odiel rivers precipitate after flowing through the Iberian Pyrite Belt, one of the largest metallogenic areas of massive sulphide deposits in the world. The proposed method satisfactorily was able to reflect different degrees of pollution on the environmental degradation index. Thus, EDI categorized littoral samples as slightly degraded and all the Tinto and some of the Odiel as very highly degraded, emphasizing the lower zone of the Tinto estuary as the most deeply degraded of the entire study area. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Criteria for assessing the quality of mHealth apps: a systematic review.

    PubMed

    Nouri, Rasool; R Niakan Kalhori, Sharareh; Ghazisaeedi, Marjan; Marchand, Guillaume; Yasini, Mobin

    2018-05-16

    Review the existing studies including an assessment tool/method to assess the quality of mHealth apps; extract their criteria; and provide a classification of the collected criteria. In accordance with the PRISMA statement, a literature search was conducted in MEDLINE, EMBase, ISI and Scopus for English language citations published from January 1, 2008 to December 22, 2016 for studies including tools or methods for quality assessment of mHealth apps. Two researchers screened the titles and abstracts of all retrieved citations against the inclusion and exclusion criteria. The full text of relevant papers was then individually examined by the same researchers. A senior researcher resolved eventual disagreements and confirmed the relevance of all included papers. The authors, date of publication, subject fields of target mHealth apps, development method, and assessment criteria were extracted from each paper. The extracted assessment criteria were then reviewed, compared, and classified by an expert panel of two medical informatics specialists and two health information management specialists. Twenty-three papers were included in the review. Thirty-eight main classes of assessment criteria were identified. These were reorganized by expert panel into 7 main classes (Design, Information/Content, Usability, Functionality, Ethical Issues, Security and Privacy, and User-perceived value) with 37 sub-classes of criteria. There is a wide heterogeneity in assessment criteria for mHealth apps. It is necessary to define the exact meanings and degree of distinctness of each criterion. This will help to improve the existing tools and may lead to achieve a better comprehensive mHealth app assessment tool.

  14. [Cardiology quality assessment in Germany--pro and contra].

    PubMed

    von Hodenberg, E; Eder, S; Grunebaum, P; Melichercik, J

    2009-10-01

    The German National Institute for Quality in Healthcare has also developed a program of external quality assessment in the field of cardiology. Hospitals are committed to collect certain data of diagnostic coronary angiography, percutaneous coronary interventions and pacemaker implantations. If statistical abnormalities are observed a so called structured dialogue is implemented. The responsible physicians of the hospitals are asked to comment possible quality deficits. Appointed members of quality commissions examine the answers and can invite the responsible physicians for interviews or also visit the hospital. However the validity of the quality data is problematic, because audits or check-ups of quality assessment in place are lacking. Therefore the results should not be misused for a comparison or ranking of hospitals with each other. As long as the validity of the quality assessment has not been improved, the results should also not be accessible for other parties, such as health insurances. Georg Thieme Verlag KG Stuttgart, New York.

  15. Considerations for using data envelopment analysis for the assessment of radiotherapy treatment plan quality.

    PubMed

    Simpson, John; Raith, Andrea; Rouse, Paul; Ehrgott, Matthias

    2017-10-09

    Purpose The operations research method of data envelopment analysis (DEA) shows promise for assessing radiotherapy treatment plan quality. The purpose of this paper is to consider the technical requirements for using DEA for plan assessment. Design/methodology/approach In total, 41 prostate treatment plans were retrospectively analysed using the DEA method. The authors investigate the impact of DEA weight restrictions with reference to the ability to differentiate plan performance at a level of clinical significance. Patient geometry influences plan quality and the authors compare differing approaches for managing patient geometry within the DEA method. Findings The input-oriented DEA method is the method of choice when performing plan analysis using the key undesirable plan metrics as the DEA inputs. When considering multiple inputs, it is necessary to constrain the DEA input weights in order to identify potential plan improvements at a level of clinical significance. All tested approaches for the consideration of patient geometry yielded consistent results. Research limitations/implications This work is based on prostate plans and individual recommendations would therefore need to be validated for other treatment sites. Notwithstanding, the method that requires both optimised DEA weights according to clinical significance and appropriate accounting for patient geometric factors is universally applicable. Practical implications DEA can potentially be used during treatment plan development to guide the planning process or alternatively used retrospectively for treatment plan quality audit. Social implications DEA is independent of the planning system platform and therefore has the potential to be used for multi-institutional quality audit. Originality/value To the authors' knowledge, this is the first published examination of the optimal approach in the use of DEA for radiotherapy treatment plan assessment.

  16. Meat Quality Assessment by Electronic Nose (Machine Olfaction Technology)

    PubMed Central

    Ghasemi-Varnamkhasti, Mahdi; Mohtasebi, Seyed Saeid; Siadat, Maryam; Balasubramanian, Sundar

    2009-01-01

    Over the last twenty years, newly developed chemical sensor systems (so called “electronic noses”) have made odor analyses possible. These systems involve various types of electronic chemical gas sensors with partial specificity, as well as suitable statistical methods enabling the recognition of complex odors. As commercial instruments have become available, a substantial increase in research into the application of electronic noses in the evaluation of volatile compounds in food, cosmetic and other items of everyday life is observed. At present, the commercial gas sensor technologies comprise metal oxide semiconductors, metal oxide semiconductor field effect transistors, organic conducting polymers, and piezoelectric crystal sensors. Further sensors based on fibreoptic, electrochemical and bi-metal principles are still in the developmental stage. Statistical analysis techniques range from simple graphical evaluation to multivariate analysis such as artificial neural network and radial basis function. The introduction of electronic noses into the area of food is envisaged for quality control, process monitoring, freshness evaluation, shelf-life investigation and authenticity assessment. Considerable work has already been carried out on meat, grains, coffee, mushrooms, cheese, sugar, fish, beer and other beverages, as well as on the odor quality evaluation of food packaging material. This paper describes the applications of these systems for meat quality assessment, where fast detection methods are essential for appropriate product management. The results suggest the possibility of using this new technology in meat handling. PMID:22454572

  17. Assessing Impacts on Unplanned Hospitalisations of Care Quality and Access Using a Structural Equation Method: With a Case Study of Diabetes

    PubMed Central

    Congdon, Peter

    2016-01-01

    Background: Enhanced quality of care and improved access are central to effective primary care management of long term conditions. However, research evidence is inconclusive in establishing a link between quality of primary care, or access, and adverse outcomes, such as unplanned hospitalisation. Methods: This paper proposes a structural equation model for quality and access as latent variables affecting adverse outcomes, such as unplanned hospitalisations. In a case study application, quality of care (QOC) is defined in relation to diabetes, and the aim is to assess impacts of care quality and access on unplanned hospital admissions for diabetes, while allowing also for socio-economic deprivation, diabetes morbidity, and supply effects. The study involves 90 general practitioner (GP) practices in two London Clinical Commissioning Groups, using clinical quality of care indicators, and patient survey data on perceived access. Results: As a single predictor, quality of care has a significant negative impact on emergency admissions, and this significant effect remains when socio-economic deprivation and morbidity are allowed. In a full structural equation model including access, the probability that QOC negatively impacts on unplanned admissions exceeds 0.9. Furthermore, poor access is linked to deprivation, diminished QOC, and larger list sizes. Conclusions: Using a Bayesian inference methodology, the evidence from the analysis is weighted towards negative impacts of higher primary care quality and improved access on unplanned admissions. The methodology of the paper is potentially applicable to other long term conditions, and relevant when care quality and access cannot be measured directly and are better regarded as latent variables. PMID:27598184

  18. Developing an Engineering Design Process Assessment using Mixed Methods.

    PubMed

    Wind, Stefanie A; Alemdar, Meltem; Lingle, Jeremy A; Gale, Jessica D; Moore, Roxanne A

    Recent reforms in science education worldwide include an emphasis on engineering design as a key component of student proficiency in the Science, Technology, Engineering, and Mathematics disciplines. However, relatively little attention has been directed to the development of psychometrically sound assessments for engineering. This study demonstrates the use of mixed methods to guide the development and revision of K-12 Engineering Design Process (EDP) assessment items. Using results from a middle-school EDP assessment, this study illustrates the combination of quantitative and qualitative techniques to inform item development and revisions. Overall conclusions suggest that the combination of quantitative and qualitative evidence provides an in-depth picture of item quality that can be used to inform the revision and development of EDP assessment items. Researchers and practitioners can use the methods illustrated here to gather validity evidence to support the interpretation and use of new and existing assessments.

  19. The method of quality marker research and quality evaluation of traditional Chinese medicine based on drug properties and effect characteristics.

    PubMed

    Zhang, Tiejun; Bai, Gang; Han, Yanqi; Xu, Jun; Gong, Suxiao; Li, Yazhuo; Zhang, Hongbing; Liu, Changxiao

    2018-05-15

    Quality of traditional Chinese medicine (TCM) plays a critical role in industry of TCM. Rapid development of TCM pharmaceutical areas is, however, greatly limited, since there are many issues not been resolved, concerning the quality study of TCM. Core concept of TCM quality as well as the characteristics of TCM was discussed, in order to guide the quality research and evaluation of TCM, further improve the level of TCM quality control. In this review, on the basis of systematic analysis of fundamental property and features of TCM in clinical application, the approaches and methods of quality marker (Q-marker) study were proposed through combination of transitivity and traceability of essentials of quality, correlation between chemical ingredients and drug property/efficacy, as well as analysis of endemicity of ingredients sharing similar pharmacophylogenetic and biosynthetic approaches. The approaches and methods of Q-marker study were proposed and the novel integrated pattern for quality assessment and control of TCM was established. The core concept of Q-marker has helped to break through the bottleneck of the current fragmented quality research of TCM and improved the scientificity, integrity and systematicness of quality control. Copyright © 2018 Elsevier GmbH. All rights reserved.

  20. Comparison of Soil Quality Index Using Three Methods

    PubMed Central

    Mukherjee, Atanu; Lal, Rattan

    2014-01-01

    Assessment of management-induced changes in soil quality is important to sustaining high crop yield. A large diversity of cultivated soils necessitate identification development of an appropriate soil quality index (SQI) based on relative soil properties and crop yield. Whereas numerous attempts have been made to estimate SQI for major soils across the World, there is no standard method established and thus, a strong need exists for developing a user-friendly and credible SQI through comparison of various available methods. Therefore, the objective of this article is to compare three widely used methods to estimate SQI using the data collected from 72 soil samples from three on-farm study sites in Ohio. Additionally, challenge lies in establishing a correlation between crop yield versus SQI calculated either depth wise or in combination of soil layers as standard methodology is not yet available and was not given much attention to date. Predominant soils of the study included one organic (Mc), and two mineral (CrB, Ko) soils. Three methods used to estimate SQI were: (i) simple additive SQI (SQI-1), (ii) weighted additive SQI (SQI-2), and (iii) statistically modeled SQI (SQI-3) based on principal component analysis (PCA). The SQI varied between treatments and soil types and ranged between 0–0.9 (1 being the maximum SQI). In general, SQIs did not significantly differ at depths under any method suggesting that soil quality did not significantly differ for different depths at the studied sites. Additionally, data indicate that SQI-3 was most strongly correlated with crop yield, the correlation coefficient ranged between 0.74–0.78. All three SQIs were significantly correlated (r = 0.92–0.97) to each other and with crop yield (r = 0.65–0.79). Separate analyses by crop variety revealed that correlation was low indicating that some key aspects of soil quality related to crop response are important requirements for estimating SQI. PMID:25148036

  1. Room for improvement? Leadership, innovation culture and uptake of quality improvement methods in general practice.

    PubMed

    Apekey, Tanefa A; McSorley, Gerry; Tilling, Michelle; Siriwardena, A Niroshan

    2011-04-01

    Leadership and innovation are currently seen as essential elements for the development and maintenance of high-quality care. Little is known about the relationship between leadership and culture of innovation and the extent to which quality improvement methods are used in general practice. This study aimed to assess the relationship between leadership behaviour, culture of innovation and adoption of quality improvement methods in general practice. Self-administered postal questionnaires were sent to general practitioner quality improvement leads in one county in the UK between June and December 2007. The questionnaire consisted of background information, a 12-item scale to assess leadership behaviour, a seven-dimension self-rating scale for culture of innovation and questions on current use of quality improvement tools and techniques. Sixty-three completed questionnaires (62%) were returned. Leadership behaviours were not commonly reported. Most practices reported a positive culture of innovation, featuring relationship most strongly, followed by targets and information but rated lower on other dimensions of rewards, risk and resources. There was a significant positive correlation between leadership behaviour and the culture of innovation (r = 0.57; P < 0.001). Apart from clinical audit and significant event analysis, quality improvement methods were not adopted by most participating practices. Leadership behaviours were infrequently reported and this was associated with a limited culture of innovation in participating general practices. There was little use of quality improvement methods beyond clinical and significant event audit. Practices need support to enhance leadership skills, encourage innovation and develop quality improvement skills if improvements in health care are to accelerate. © 2010 Blackwell Publishing Ltd.

  2. Deep supervised dictionary learning for no-reference image quality assessment

    NASA Astrophysics Data System (ADS)

    Huang, Yuge; Liu, Xuesong; Tian, Xiang; Zhou, Fan; Chen, Yaowu; Jiang, Rongxin

    2018-03-01

    We propose a deep convolutional neural network (CNN) for general no-reference image quality assessment (NR-IQA), i.e., accurate prediction of image quality without a reference image. The proposed model consists of three components such as a local feature extractor that is a fully CNN, an encoding module with an inherent dictionary that aggregates local features to output a fixed-length global quality-aware image representation, and a regression module that maps the representation to an image quality score. Our model can be trained in an end-to-end manner, and all of the parameters, including the weights of the convolutional layers, the dictionary, and the regression weights, are simultaneously learned from the loss function. In addition, the model can predict quality scores for input images of arbitrary sizes in a single step. We tested our method on commonly used image quality databases and showed that its performance is comparable with that of state-of-the-art general-purpose NR-IQA algorithms.

  3. Weighted-MSE based on saliency map for assessing video quality of H.264 video streams

    NASA Astrophysics Data System (ADS)

    Boujut, H.; Benois-Pineau, J.; Hadar, O.; Ahmed, T.; Bonnet, P.

    2011-01-01

    Human vision system is very complex and has been studied for many years specifically for purposes of efficient encoding of visual, e.g. video content from digital TV. There have been physiological and psychological evidences which indicate that viewers do not pay equal attention to all exposed visual information, but only focus on certain areas known as focus of attention (FOA) or saliency regions. In this work, we propose a novel based objective quality assessment metric, for assessing the perceptual quality of decoded video sequences affected by transmission errors and packed loses. The proposed method weights the Mean Square Error (MSE), Weighted-MSE (WMSE), according to the calculated saliency map at each pixel. Our method was validated trough subjective quality experiments.

  4. Review of Comprehensive Evaluation Methods for Power Quality and Its Trend in New Generation Energy System

    NASA Astrophysics Data System (ADS)

    Liu, Ruihua; Wang, Rong; Liu, Qunying; Yang, Li; Xi, Chuan; Wang, Wei; Li, Lingzhou; Zhao, Zhoufang; Zhou, Ying

    2018-02-01

    With China’s new energy generation grid connected capacity being in the forefront of the world and the uncertainty of new energy sources, such as wind energy and solar energy, it is be of great significance to study scientific and comprehensive assessment of power quality. On the foundation of analysizing the current power quality index systematically and objectively, the new energy grid power quality analysis method and comprehensive evaluation method, this paper tentatively explored the trend of the new generation of energy system power quality comprehensive evaluation.

  5. Next-generation sequencing (NGS) for assessment of microbial water quality: current progress, challenges, and future opportunities

    PubMed Central

    Tan, BoonFei; Ng, Charmaine; Nshimyimana, Jean Pierre; Loh, Lay Leng; Gin, Karina Y.-H.; Thompson, Janelle R.

    2015-01-01

    Water quality is an emergent property of a complex system comprised of interacting microbial populations and introduced microbial and chemical contaminants. Studies leveraging next-generation sequencing (NGS) technologies are providing new insights into the ecology of microbially mediated processes that influence fresh water quality such as algal blooms, contaminant biodegradation, and pathogen dissemination. In addition, sequencing methods targeting small subunit (SSU) rRNA hypervariable regions have allowed identification of signature microbial species that serve as bioindicators for sewage contamination in these environments. Beyond amplicon sequencing, metagenomic and metatranscriptomic analyses of microbial communities in fresh water environments reveal the genetic capabilities and interplay of waterborne microorganisms, shedding light on the mechanisms for production and biodegradation of toxins and other contaminants. This review discusses the challenges and benefits of applying NGS-based methods to water quality research and assessment. We will consider the suitability and biases inherent in the application of NGS as a screening tool for assessment of biological risks and discuss the potential and limitations for direct quantitative interpretation of NGS data. Secondly, we will examine case studies from recent literature where NGS based methods have been applied to topics in water quality assessment, including development of bioindicators for sewage pollution and microbial source tracking, characterizing the distribution of toxin and antibiotic resistance genes in water samples, and investigating mechanisms of biodegradation of harmful pollutants that threaten water quality. Finally, we provide a short review of emerging NGS platforms and their potential applications to the next generation of water quality assessment tools. PMID:26441948

  6. QUAST: quality assessment tool for genome assemblies

    PubMed Central

    Gurevich, Alexey; Saveliev, Vladislav; Vyahhi, Nikolay; Tesler, Glenn

    2013-01-01

    Summary: Limitations of genome sequencing techniques have led to dozens of assembly algorithms, none of which is perfect. A number of methods for comparing assemblers have been developed, but none is yet a recognized benchmark. Further, most existing methods for comparing assemblies are only applicable to new assemblies of finished genomes; the problem of evaluating assemblies of previously unsequenced species has not been adequately considered. Here, we present QUAST—a quality assessment tool for evaluating and comparing genome assemblies. This tool improves on leading assembly comparison software with new ideas and quality metrics. QUAST can evaluate assemblies both with a reference genome, as well as without a reference. QUAST produces many reports, summary tables and plots to help scientists in their research and in their publications. In this study, we used QUAST to compare several genome assemblers on three datasets. QUAST tables and plots for all of them are available in the Supplementary Material, and interactive versions of these reports are on the QUAST website. Availability: http://bioinf.spbau.ru/quast Contact: gurevich@bioinf.spbau.ru Supplementary information: Supplementary data are available at Bioinformatics online. PMID:23422339

  7. Nanotechnology for Food Packaging and Food Quality Assessment.

    PubMed

    Rossi, Marco; Passeri, Daniele; Sinibaldi, Alberto; Angjellari, Mariglen; Tamburri, Emanuela; Sorbo, Angela; Carata, Elisabetta; Dini, Luciana

    Nanotechnology has paved the way to innovative food packaging materials and analytical methods to provide the consumers with healthier food and to reduce the ecological footprint of the whole food chain. Combining antimicrobial and antifouling properties, thermal and mechanical protection, oxygen and moisture barrier, as well as to verify the actual quality of food, e.g., sensors to detect spoilage, bacterial growth, and to monitor incorrect storage conditions, or anticounterfeiting devices in food packages may extend the products shelf life and ensure higher quality of foods. Also the ecological footprint of food chain can be reduced by developing new completely recyclable and/or biodegradable packages from natural and eco-friendly resources. The contribution of nanotechnologies to these goals is reviewed in this chapter, together with a description of portable devices ("lab-on-chip," sensors, nanobalances, etc.) which can be used to assess the quality of food and an overview of regulations in force on food contact materials. © 2017 Elsevier Inc. All rights reserved.

  8. Non-Destructive Spectroscopic Techniques and Multivariate Analysis for Assessment of Fat Quality in Pork and Pork Products: A Review

    PubMed Central

    Kucha, Christopher T.; Liu, Li; Ngadi, Michael O.

    2018-01-01

    Fat is one of the most important traits determining the quality of pork. The composition of the fat greatly influences the quality of pork and its processed products, and contribute to defining the overall carcass value. However, establishing an efficient method for assessing fat quality parameters such as fatty acid composition, solid fat content, oxidative stability, iodine value, and fat color, remains a challenge that must be addressed. Conventional methods such as visual inspection, mechanical methods, and chemical methods are used off the production line, which often results in an inaccurate representation of the process because the dynamics are lost due to the time required to perform the analysis. Consequently, rapid, and non-destructive alternative methods are needed. In this paper, the traditional fat quality assessment techniques are discussed with emphasis on spectroscopic techniques as an alternative. Potential spectroscopic techniques include infrared spectroscopy, nuclear magnetic resonance and Raman spectroscopy. Hyperspectral imaging as an emerging advanced spectroscopy-based technology is introduced and discussed for the recent development of assessment for fat quality attributes. All techniques are described in terms of their operating principles and the research advances involving their application for pork fat quality parameters. Future trends for the non-destructive spectroscopic techniques are also discussed. PMID:29382092

  9. Evaluation of ride quality prediction methods for operational military helicopters

    NASA Technical Reports Server (NTRS)

    Leatherwood, J. D.; Clevenson, S. A.; Hollenbaugh, D. D.

    1984-01-01

    The results of a simulator study conducted to compare and validate various ride quality prediction methods for use in assessing passenger/crew ride comfort within helicopters are presented. Included are results quantifying 35 helicopter pilots' discomfort responses to helicopter interior noise and vibration typical of routine flights, assessment of various ride quality metrics including the NASA ride comfort model, and examination of possible criteria approaches. Results of the study indicated that crew discomfort results from a complex interaction between vibration and interior noise. Overall measures such as weighted or unweighted root-mean-square acceleration level and A-weighted noise level were not good predictors of discomfort. Accurate prediction required a metric incorporating the interactive effects of both noise and vibration. The best metric for predicting crew comfort to the combined noise and vibration environment was the NASA discomfort index.

  10. Evaluating the Impact of Library Instruction Methods on the Quality of Student Research.

    ERIC Educational Resources Information Center

    Ackerson, Linda G.; Young, Virgina E.

    1994-01-01

    A three-year study at the University of Alabama compared a traditional lecture method for teaching library research skills with a course-integrated, computer-enhanced approach by assessing each method's impact on the quality of bibliographies from engineering students' term papers. In four of the five semesters, no significant differences were…

  11. A method to estimate spatiotemporal air quality in an urban traffic corridor.

    PubMed

    Singh, Nongthombam Premananda; Gokhale, Sharad

    2015-12-15

    Air quality exposure assessment using personal exposure sampling or direct measurement of spatiotemporal air pollutant concentrations has difficulty and limitations. Most statistical methods used for estimating spatiotemporal air quality do not account for the source characteristics (e.g. emissions). In this study, a prediction method, based on the lognormal probability distribution of hourly-average-spatial concentrations of carbon monoxide (CO) obtained by a CALINE4 model, has been developed and validated in an urban traffic corridor. The data on CO concentrations were collected at three locations and traffic and meteorology within the urban traffic corridor.(1) The method has been developed with the data of one location and validated at other two locations. The method estimated the CO concentrations reasonably well (correlation coefficient, r≥0.96). Later, the method has been applied to estimate the probability of occurrence [P(C≥Cstd] of the spatial CO concentrations in the corridor. The results have been promising and, therefore, may be useful to quantifying spatiotemporal air quality within an urban area. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. An Optical Flow-Based Full Reference Video Quality Assessment Algorithm.

    PubMed

    K, Manasa; Channappayya, Sumohana S

    2016-06-01

    We present a simple yet effective optical flow-based full-reference video quality assessment (FR-VQA) algorithm for assessing the perceptual quality of natural videos. Our algorithm is based on the premise that local optical flow statistics are affected by distortions and the deviation from pristine flow statistics is proportional to the amount of distortion. We characterize the local flow statistics using the mean, the standard deviation, the coefficient of variation (CV), and the minimum eigenvalue ( λ min ) of the local flow patches. Temporal distortion is estimated as the change in the CV of the distorted flow with respect to the reference flow, and the correlation between λ min of the reference and of the distorted patches. We rely on the robust multi-scale structural similarity index for spatial quality estimation. The computed temporal and spatial distortions, thus, are then pooled using a perceptually motivated heuristic to generate a spatio-temporal quality score. The proposed method is shown to be competitive with the state-of-the-art when evaluated on the LIVE SD database, the EPFL Polimi SD database, and the LIVE Mobile HD database. The distortions considered in these databases include those due to compression, packet-loss, wireless channel errors, and rate-adaptation. Our algorithm is flexible enough to allow for any robust FR spatial distortion metric for spatial distortion estimation. In addition, the proposed method is not only parameter-free but also independent of the choice of the optical flow algorithm. Finally, we show that the replacement of the optical flow vectors in our proposed method with the much coarser block motion vectors also results in an acceptable FR-VQA algorithm. Our algorithm is called the flow similarity index.

  13. Drinking water quality assessment.

    PubMed

    Aryal, J; Gautam, B; Sapkota, N

    2012-09-01

    Drinking water quality is the great public health concern because it is a major risk factor for high incidence of diarrheal diseases in Nepal. In the recent years, the prevalence rate of diarrhoea has been found the highest in Myagdi district. This study was carried out to assess the quality of drinking water from different natural sources, reservoirs and collection taps at Arthunge VDC of Myagdi district. A cross-sectional study was carried out using random sampling method in Arthunge VDC of Myagdi district from January to June,2010. 84 water samples representing natural sources, reservoirs and collection taps from the study area were collected. The physico-chemical and microbiological analysis was performed following standards technique set by APHA 1998 and statistical analysis was carried out using SPSS 11.5. The result was also compared with national and WHO guidelines. Out of 84 water samples (from natural source, reservoirs and tap water) analyzed, drinking water quality parameters (except arsenic and total coliform) of all water samples was found to be within the WHO standards and national standards.15.48% of water samples showed pH (13) higher than the WHO permissible guideline values. Similarly, 85.71% of water samples showed higher Arsenic value (72) than WHO value. Further, the statistical analysis showed no significant difference (P<0.05) of physico-chemical parameters and total coliform count of drinking water for collection taps water samples of winter (January, 2010) and summer (June, 2010). The microbiological examination of water samples revealed the presence of total coliform in 86.90% of water samples. The results obtained from physico-chemical analysis of water samples were within national standard and WHO standards except arsenic. The study also found the coliform contamination to be the key problem with drinking water.

  14. A CNN based neurobiology inspired approach for retinal image quality assessment.

    PubMed

    Mahapatra, Dwarikanath; Roy, Pallab K; Sedai, Suman; Garnavi, Rahil

    2016-08-01

    Retinal image quality assessment (IQA) algorithms use different hand crafted features for training classifiers without considering the working of the human visual system (HVS) which plays an important role in IQA. We propose a convolutional neural network (CNN) based approach that determines image quality using the underlying principles behind the working of the HVS. CNNs provide a principled approach to feature learning and hence higher accuracy in decision making. Experimental results demonstrate the superior performance of our proposed algorithm over competing methods.

  15. Assessment of Ganga river ecosystem at Haridwar, Uttarakhand, India with reference to water quality indices

    NASA Astrophysics Data System (ADS)

    Bhutiani, R.; Khanna, D. R.; Kulkarni, Dipali Bhaskar; Ruhela, Mukesh

    2016-06-01

    The river Ganges is regarded as one of the most holy and sacred rivers of the world from time immemorial. The evaluation of river water quality is a critical element in the assessment of water resources. The quality/potability of water that is consumed defines the base line of protection against many diseases and infections. The present study aimed to calculate Water Quality Index (WQI) by the analysis of sixteen physico-chemical parameters on the basis of River Ganga index of Ved Prakash, weighted arithmetic index and WQI by National sanitation foundation (NSF) to assess the suitability of water for drinking, irrigation purposes and other human uses. These three water quality indices have been used to assess variation in the quality of the River Ganga at monitored locations over an 11-year period. Application of three different indexes to assess the water quality over a period of 11 years shows minor variations in water quality. Index values as per River Ganga Index by Ved Prakash et al. from 2000 to 2010 ranged between medium to good, Index values as per NSF Index for years 2000-2010 indicate good water quality, while Index values as per the weighted arithmetic index method for the study period indicate poor water quality.

  16. Quality-of-Life Assessment of Fibroid Treatment Options and Outcomes

    PubMed Central

    Kong, Chung Yin; Tempany, Clare M.; Swan, J. Shannon

    2011-01-01

    Purpose: To obtain utilities (a unit of measure of a person’s relative preferences for different health states compared with death or worst possible outcome) for uterine fibroids before and after treatment and to measure short-term utilities for the following uterine fibroid treatments: abdominal hysterectomy, magnetic resonance (MR) imaging–guided focused ultrasound surgery, and uterine artery embolization (UAE). Materials and Methods: This retrospective study was approved by the institutional review board and was HIPAA compliant. The waiting trade-off (WTO) method, a variation on the time trade-off (TTO) method, is used to obtain utilities for diagnostic procedures on the basis of the fact that people wait longer to avoid noxious tests and/or procedures. The WTO method provides short-term quality of life tolls in terms of quality-adjusted life-weeks by scaling wait times with pre- and posttreatment utilities. Utilities for uterine fibroids before and after treatment were obtained with the TTO method and a visual analog scale (VAS) by using a questionnaire administered by means of a phone interview. WTO wait times were adjusted for quality of life with VAS and TTO utilities and a transformation of VAS. Wait times were compared by using nonparametric tests. The study participants included 62 patients who had undergone abdominal hysterectomy, 74 who had undergone UAE, and 61 who had undergone MR imaging–guided focused ultrasound surgery. Results: Quality of life increased with all treatments. The median WTO wait time was higher for hysterectomy (21.6 weeks) than for UAE or MR imaging–guided focused ultrasound surgery (14.1 weeks for both) (P < .05). Quality-adjusted life-week tolls were smaller when scaled according to TTO than when scaled according to VAS or transformation of VAS. Conclusion: Quality of life increased after all fibroid treatments. WTO is feasible for assessing the quality-adjusted morbidity of treatment procedures. © RSNA, 2011

  17. Improved methods for national water assessment, water resources contract: WR15249270

    USGS Publications Warehouse

    Thomas, Harold A.

    1981-01-01

    The purpose of our research is to develop methods to make National Water Assessment more useful in estimating water availability for economic growth and more helpful in determining the effect of water resource development upon the environmental quality of related land resources. There are serious questions pertaining to the 1975 Water Assessment and these amplify the significance of decisions made as to the planning and scheduling of the next assessment.

  18. Aerial photography flight quality assessment with GPS/INS and DEM data

    NASA Astrophysics Data System (ADS)

    Zhao, Haitao; Zhang, Bing; Shang, Jiali; Liu, Jiangui; Li, Dong; Chen, Yanyan; Zuo, Zhengli; Chen, Zhengchao

    2018-01-01

    The flight altitude, ground coverage, photo overlap, and other acquisition specifications of an aerial photography flight mission directly affect the quality and accuracy of the subsequent mapping tasks. To ensure smooth post-flight data processing and fulfill the pre-defined mapping accuracy, flight quality assessments should be carried out in time. This paper presents a novel and rigorous approach for flight quality evaluation of frame cameras with GPS/INS data and DEM, using geometric calculation rather than image analysis as in the conventional methods. This new approach is based mainly on the collinearity equations, in which the accuracy of a set of flight quality indicators is derived through a rigorous error propagation model and validated with scenario data. Theoretical analysis and practical flight test of an aerial photography mission using an UltraCamXp camera showed that the calculated photo overlap is accurate enough for flight quality assessment of 5 cm ground sample distance image, using the SRTMGL3 DEM and the POSAV510 GPS/INS data. An even better overlap accuracy could be achieved for coarser-resolution aerial photography. With this new approach, the flight quality evaluation can be conducted on site right after landing, providing accurate and timely information for decision making.

  19. Informatics: essential infrastructure for quality assessment and improvement in nursing.

    PubMed Central

    Henry, S B

    1995-01-01

    In recent decades there have been major advances in the creation and implementation of information technologies and in the development of measures of health care quality. The premise of this article is that informatics provides essential infrastructure for quality assessment and improvement in nursing. In this context, the term quality assessment and improvement comprises both short-term processes such as continuous quality improvement (CQI) and long-term outcomes management. This premise is supported by 1) presentation of a historical perspective on quality assessment and improvement; 2) delineation of the types of data required for quality assessment and improvement; and 3) description of the current and potential uses of information technology in the acquisition, storage, transformation, and presentation of quality data, information, and knowledge. PMID:7614118

  20. Quality assessment tools add value.

    PubMed

    Paul, L

    1996-10-01

    The rapid evolution of the health care marketplace can be expected to continue as we move closer to the 21st Century. Externally-imposed pressures for cost reduction will increasingly be accompanied by pressure within health care organizations as risk-sharing reimbursement arrangements become more commonplace. Competitive advantage will be available to those organizations that can demonstrate objective value as defined by the cost-quality equation. The tools an organization chooses to perform quality assessment will be an important factor in its ability to demonstrate such value. Traditional quality assurance will in all likelihood continue, but the extent to which quality improvement activities are adopted by the culture of an organization may determine its ability to provide objective evidence of better health status outcomes.

  1. The Q-Sort method: use in landscape assessment research and landscape planning

    Treesearch

    David G. Pitt; Ervin H. Zube

    1979-01-01

    The assessment of visual quality inherently involves the measurement of perceptual response to landscape. The Q-Sort Method is a psychometric technique which produces reliable and valid interval measurements of people's perceptions of landscape visual quality as depicted in photographs. It is readily understood by participants across a wide range of age groups and...

  2. An assessment of drinking-water quality post-Haiyan

    PubMed Central

    Anarna, Maria Sonabel; Fernando, Arturo

    2015-01-01

    Introduction Access to safe drinking-water is one of the most important public health concerns in an emergency setting. This descriptive study reports on an assessment of water quality in drinking-water supply systems in areas affected by Typhoon Haiyan immediately following and 10 months after the typhoon. Methods Water quality testing and risk assessments of the drinking-water systems were conducted three weeks and 10 months post-Haiyan. Portable test kits were used to determine the presence of Escherichia coli and the level of residual chlorine in water samples. The level of risk was fed back to the water operators for their action. Results Of the 121 water samples collected three weeks post-Haiyan, 44% were contaminated, while 65% (244/373) of samples were found positive for E. coli 10 months post-Haiyan. For the three components of drinking-water systems – source, storage and distribution – the proportions of contaminated systems were 70%, 67% and 57%, respectively, 10 months after Haiyan. Discussion Vulnerability to faecal contamination was attributed to weak water safety programmes in the drinking-water supply systems. Poor water quality can be prevented or reduced by developing and implementing a water safety plan for the systems. This, in turn, will help prevent waterborne disease outbreaks caused by contaminated water post-disaster. PMID:26767136

  3. Feasibility of a Computerized Method to Measure Quality of "Everyday" Life in Children with Neuromuscular Disorders

    ERIC Educational Resources Information Center

    Bray, Paula; Bundy, Anita C.; Ryan, Monique M.; North, Kathryn N.

    2010-01-01

    Measurement of quality of life is becoming increasingly important in health care. Self-reported quality of life is the preferred method of gathering this information, but children are often excluded from this process, their input being replaced by parent-proxy report. This feasibility study tested assessment of "daily" quality-of-life by a…

  4. Assessing the quality of care in a new nation: South Sudan's first national health facility assessment.

    PubMed

    Berendes, Sima; Lako, Richard L; Whitson, Donald; Gould, Simon; Valadez, Joseph J

    2014-10-01

    We adapted a rapid quality of care monitoring method to a fragile state with two aims: to assess the delivery of child health services in South Sudan at the time of independence and to strengthen local capacity to perform regular rapid health facility assessments. Using a two-stage lot quality assurance sampling (LQAS) design, we conducted a national cross-sectional survey among 156 randomly selected health facilities in 10 states. In each of these facilities, we obtained information on a range of access, input, process and performance indicators during structured interviews and observations. Quality of care was poor with all states failing to achieve the 80% target for 14 of 19 indicators. For example, only 12% of facilities were classified as acceptable for their adequate utilisation by the population for sick-child consultations, 16% for staffing, 3% for having infection control supplies available and 0% for having all child care guidelines. Health worker performance was categorised as acceptable in only 6% of cases related to sick-child assessments, 38% related to medical treatment for the given diagnosis and 33% related to patient counselling on how to administer the prescribed drugs. Best performance was recorded for availability of in-service training and supervision, for seven and ten states, respectively. Despite ongoing instability, the Ministry of Health developed capacity to use LQAS for measuring quality of care nationally and state-by-state, which will support efficient and equitable resource allocation. Overall, our data revealed a desperate need for improving the quality of care in all states. © 2014 John Wiley & Sons Ltd.

  5. Constructing Ecological Networks Based on Habitat Quality Assessment: A Case Study of Changzhou, China

    NASA Astrophysics Data System (ADS)

    Gao, Yu; Ma, Lei; Liu, Jiaxun; Zhuang, Zhuzhou; Huang, Qiuhao; Li, Manchun

    2017-04-01

    Fragmentation and reduced continuity of habitat patches threaten the environment and biodiversity. Recently, ecological networks are increasingly attracting the attention of researchers as they provide fundamental frameworks for environmental protection. This study suggests a set of procedures to construct an ecological network. First, we proposed a method to construct a landscape resistance surface based on the assessment of habitat quality. Second, to analyze the effect of the resistance surface on corridor simulations, we used three methods to construct resistance surfaces: (1) the method proposed in this paper, (2) the entropy coefficient method, and (3) the expert scoring method. Then, we integrated habitat patches and resistance surfaces to identify potential corridors using graph theory. These procedures were tested in Changzhou, China. Comparing the outputs of using different resistance surfaces demonstrated that: (1) different landscape resistance surfaces contribute to how corridors are identified, but only slightly affect the assessment of the importance of habitat patches and potential corridors; (2) the resistance surface, which is constructed based on habitat quality, is more applicable to corridor simulations; and (3) the assessment of the importance of habitat patches is fundamental for ecological network optimization in the conservation of critical habitat patches and corridors.

  6. [Development of methods and instruments for external quality assurance in inpatient parent-child rehabilitation and prevention].

    PubMed

    Neuderth, S; Lukasczik, M; Musekamp, G; Gerlich, C; Saupe-Heide, M; Löbmann, R; Vogel, H

    2013-02-01

    There so far is no standardized program for external quality assurance in inpatient parent-child prevention and rehabilitation in Germany. Therefore, instruments and methods of external quality assurance were developed and evaluated on behalf of the federal-level health insurance institutions. On the level of structure quality, a modular questionnaire for assessing structural features of rehabilitation/prevention centers, basic and allocation criteria as well as a checklist for visitations were developed. Structural data were collected in a nationwide survey of parent-child prevention and rehabilitation centers. Process and outcome quality data were collected in n=38 centers. Process quality was assessed using multiple methods (process-related structural features, case-related routine documentation, and incident-related patient questionnaires). Outcome quality was measured via patient questionnaires (n=1 799 patients). We used a multi-level modelling approach by adjusting relevant confounders on institutional and patient levels. The methods, instruments and analyzing procedures developed for measuring quality on the level of structure, processes and outcomes were adjusted in cooperation with all relevant stakeholders. Results are exemplarily presented for all quality assurance tools. For most of the risk-adjusted outcome parameters, we found no significant differences between institutions. For the first time, a comprehensive, standardized and generally applicable set of methods and instruments for routine use in comparative quality measurement of inpatient parent-child prevention and rehabilitation is available. However, it should be considered that the very heterogeneous field of family-oriented measures can not be covered entirely by an external quality assurance program. Therefore, methods and instruments have to be adapted continuously to the specifics of this area of health care and to new developments. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Water-Quality Assessment of the High Plains Aquifer, 1999-2004

    USGS Publications Warehouse

    McMahon, Peter B.; Dennehy, Kevin F.; Bruce, Breton W.; Gurdak, Jason J.; Qi, Sharon L.

    2007-01-01

    Water quality of the High Plains aquifer was assessed for the period 1999-2004 as part of the U.S. Geological Survey's National Water-Quality Assessment (NAWQA) Program. This effort represents the first systematic regional assessment of water quality in this nationally important aquifer. A stratified, nested group of studies was designed to assess linkages between the quality of water recharging the aquifer, the effect of transport through the hydrologic system on water quality, and the quality of the resource used for human consumption and agricultural applications. The stratified, nested design facilitated upscaling of monitoring results to unmonitored areas of the aquifer as well as upscaling of process understanding from local to regional scales.

  8. Multiparametric comparison of chromogenic-based culture methods used to assess the microbiological quality of drinking water and the mFC method combined with a molecular confirmation procedure.

    PubMed

    Maheux, Andrée F; Dion-Dupont, Vanessa; Bisson, Marc-Antoine; Bouchard, Sébastien; Jubinville, Éric; Nkuranga, Martine; Rodrigue, Lynda; Bergeron, Michel G; Rodriguez, Manuel J

    2015-03-01

    MI agar and Colilert(®), as well as mFC agar combined with an Escherichia coli-specific molecular assay (mFC + E. coli rtPCR), were compared in terms of their sensitivity, ease of use, time to result and affordability. The three methods yielded a positive E. coli signal for 11.5, 10.8, and 11.5% of the 968 well water samples tested, respectively. One hundred and thirty-six (136) samples gave blue colonies on mFC agar and required confirmation. E. coli-specific rtPCR showed false-positive results in 23.5% (32/136) of cases. In terms of ease of use, Colilert was the simplest method to use while the MI method provided ease of use comparable to all membrane filtration methods. However, the mFC + E. coli rtPCR assay required highly trained employees for confirmation purposes. In terms of affordability, and considering contamination rate of well water samples tested, the Colilert method and the mFC + E. coli rtPCR assay were at least five times more costly than the MI agar method. Overall, compared with the other two methods tested, the MI agar method offers the most advantages to assess drinking water quality.

  9. Novel approaches to assess the quality of fertility data stored in dairy herd management software.

    PubMed

    Hermans, K; Waegeman, W; Opsomer, G; Van Ranst, B; De Koster, J; Van Eetvelde, M; Hostens, M

    2017-05-01

    Scientific journals and popular press magazines are littered with articles in which the authors use data from dairy herd management software. Almost none of such papers include data cleaning and data quality assessment in their study design despite this being a very critical step during data mining. This paper presents 2 novel data cleaning methods that permit identification of animals with good and bad data quality. The first method is a deterministic or rule-based data cleaning method. Reproduction and mutation or life-changing events such as birth and death were converted to a symbolic (alphabetical letter) representation and split into triplets (3-letter code). The triplets were manually labeled as physiologically correct, suspicious, or impossible. The deterministic data cleaning method was applied to assess the quality of data stored in dairy herd management from 26 farms enrolled in the herd health management program from the Faculty of Veterinary Medicine Ghent University, Belgium. In total, 150,443 triplets were created, 65.4% were labeled as correct, 17.4% as suspicious, and 17.2% as impossible. The second method, a probabilistic method, uses a machine learning algorithm (random forests) to predict the correctness of fertility and mutation events in an early stage of data cleaning. The prediction accuracy of the random forests algorithm was compared with a classical linear statistical method (penalized logistic regression), outperforming the latter substantially, with a superior receiver operating characteristic curve and a higher accuracy (89 vs. 72%). From those results, we conclude that the triplet method can be used to assess the quality of reproduction data stored in dairy herd management software and that a machine learning technique such as random forests is capable of predicting the correctness of fertility data. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  10. ADSA Foundation Scholar Award: Trends in culture-independent methods for assessing dairy food quality and safety: emerging metagenomic tools.

    PubMed

    Yeung, Marie

    2012-12-01

    Enhancing the quality and safety of dairy food is critical to maintaining the competitiveness of dairy products in the food and beverage market and in reinforcing consumer confidence in the dairy industry. Raw milk quality has a significant effect on finished product quality. Several microbial groups found in raw milk have been shown to adversely affect the shelf life of pasteurized milk. Current microbiological criteria used to define milk quality are based primarily on culture-dependent methods, some of which are perceived to lack the desired sensitivity and specificity. To supplement traditional methods, culture-independent methods are increasingly being used to identify specific species or microbial groups, and to detect indicator genes or proteins in raw milk or dairy products. Some molecular subtyping techniques have been developed to track the transmission of microbes in dairy environments. The burgeoning "-omics" technologies offer new and exciting opportunities to enhance our understanding of food quality and safety in relation to microbes. Metagenomics has the potential to characterize microbial diversity, detect nonculturable microbes, and identify unique sequences or other factors associated with dairy product quality and safety. In this review, fluid milk will be used as the primary example to examine the adequacy and validity of conventional methods, the current trend of culture-independent methods, and the potential applications of metagenomics in dairy food research. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  11. The effect of clustering on lot quality assurance sampling: a probabilistic model to calculate sample sizes for quality assessments

    PubMed Central

    2013-01-01

    Background Traditional Lot Quality Assurance Sampling (LQAS) designs assume observations are collected using simple random sampling. Alternatively, randomly sampling clusters of observations and then individuals within clusters reduces costs but decreases the precision of the classifications. In this paper, we develop a general framework for designing the cluster(C)-LQAS system and illustrate the method with the design of data quality assessments for the community health worker program in Rwanda. Results To determine sample size and decision rules for C-LQAS, we use the beta-binomial distribution to account for inflated risk of errors introduced by sampling clusters at the first stage. We present general theory and code for sample size calculations. The C-LQAS sample sizes provided in this paper constrain misclassification risks below user-specified limits. Multiple C-LQAS systems meet the specified risk requirements, but numerous considerations, including per-cluster versus per-individual sampling costs, help identify optimal systems for distinct applications. Conclusions We show the utility of C-LQAS for data quality assessments, but the method generalizes to numerous applications. This paper provides the necessary technical detail and supplemental code to support the design of C-LQAS for specific programs. PMID:24160725

  12. The effect of clustering on lot quality assurance sampling: a probabilistic model to calculate sample sizes for quality assessments.

    PubMed

    Hedt-Gauthier, Bethany L; Mitsunaga, Tisha; Hund, Lauren; Olives, Casey; Pagano, Marcello

    2013-10-26

    Traditional Lot Quality Assurance Sampling (LQAS) designs assume observations are collected using simple random sampling. Alternatively, randomly sampling clusters of observations and then individuals within clusters reduces costs but decreases the precision of the classifications. In this paper, we develop a general framework for designing the cluster(C)-LQAS system and illustrate the method with the design of data quality assessments for the community health worker program in Rwanda. To determine sample size and decision rules for C-LQAS, we use the beta-binomial distribution to account for inflated risk of errors introduced by sampling clusters at the first stage. We present general theory and code for sample size calculations.The C-LQAS sample sizes provided in this paper constrain misclassification risks below user-specified limits. Multiple C-LQAS systems meet the specified risk requirements, but numerous considerations, including per-cluster versus per-individual sampling costs, help identify optimal systems for distinct applications. We show the utility of C-LQAS for data quality assessments, but the method generalizes to numerous applications. This paper provides the necessary technical detail and supplemental code to support the design of C-LQAS for specific programs.

  13. Methodological Quality Assessment of Meta-Analyses of Hyperthyroidism Treatment.

    PubMed

    Qin, Yahong; Yao, Liang; Shao, Feifei; Yang, Kehu; Tian, Limin

    2018-01-01

    Hyperthyroidism is a common condition that is associated with increased morbidity and mortality. A number of meta-analyses (MAs) have assessed the therapeutic measures for hyperthyroidism, including antithyroid drugs, surgery, and radioiodine, however, the methodological quality has not been evaluated. This study evaluated the methodological quality and summarized the evidence obtained from MAs of hyperthyroidism treatments for radioiodine, antithyroid drugs, and surgery. We searched the PubMed, EMBASE, Cochrane Library, Web of Science, and Chinese Biomedical Literature Database databases. Two investigators independently assessed the meta-analyses titles and abstracts for inclusion. Methodological quality was assessed using the validated AMSTAR (Assessing the Methodological Quality of Systematic Reviews) tool. A total of 26 MAs fulfilled the inclusion criteria. Based on the AMSTAR scores, the average methodological quality was 8.31, with large variability ranging from 4 to 11. The methodological quality of English meta-analyses was better than that of Chinese meta-analyses. Cochrane reviews had better methodological quality than non-Cochrane reviews due to better study selection and data extraction, the inclusion of unpublished studies, and better reporting of study characteristics. The authors did not report conflicts of interest in 53.8% meta-analyses, and 19.2% did not report the harmful effects of treatment. Publication bias was not assessed in 38.5% of meta-analyses, and 19.2% did not report the follow-up time. Large-scale assessment of methodological quality of meta-analyses of hyperthyroidism treatment highlighted methodological strengths and weaknesses. Consideration of scientific quality when formulating conclusions should be made explicit. Future meta-analyses should improve on reporting conflict of interest. © Georg Thieme Verlag KG Stuttgart · New York.

  14. ATACseqQC: a Bioconductor package for post-alignment quality assessment of ATAC-seq data.

    PubMed

    Ou, Jianhong; Liu, Haibo; Yu, Jun; Kelliher, Michelle A; Castilla, Lucio H; Lawson, Nathan D; Zhu, Lihua Julie

    2018-03-01

    ATAC-seq (Assays for Transposase-Accessible Chromatin using sequencing) is a recently developed technique for genome-wide analysis of chromatin accessibility. Compared to earlier methods for assaying chromatin accessibility, ATAC-seq is faster and easier to perform, does not require cross-linking, has higher signal to noise ratio, and can be performed on small cell numbers. However, to ensure a successful ATAC-seq experiment, step-by-step quality assurance processes, including both wet lab quality control and in silico quality assessment, are essential. While several tools have been developed or adopted for assessing read quality, identifying nucleosome occupancy and accessible regions from ATAC-seq data, none of the tools provide a comprehensive set of functionalities for preprocessing and quality assessment of aligned ATAC-seq datasets. We have developed a Bioconductor package, ATACseqQC, for easily generating various diagnostic plots to help researchers quickly assess the quality of their ATAC-seq data. In addition, this package contains functions to preprocess aligned ATAC-seq data for subsequent peak calling. Here we demonstrate the utilities of our package using 25 publicly available ATAC-seq datasets from four studies. We also provide guidelines on what the diagnostic plots should look like for an ideal ATAC-seq dataset. This software package has been used successfully for preprocessing and assessing several in-house and public ATAC-seq datasets. Diagnostic plots generated by this package will facilitate the quality assessment of ATAC-seq data, and help researchers to evaluate their own ATAC-seq experiments as well as select high-quality ATAC-seq datasets from public repositories such as GEO to avoid generating hypotheses or drawing conclusions from low-quality ATAC-seq experiments. The software, source code, and documentation are freely available as a Bioconductor package at https://bioconductor.org/packages/release/bioc/html/ATACseqQC.html .

  15. Lack of grading agreement among international hemostasis external quality assessment programs

    PubMed Central

    Olson, John D.; Jennings, Ian; Meijer, Piet; Bon, Chantal; Bonar, Roslyn; Favaloro, Emmanuel J.; Higgins, Russell A.; Keeney, Michael; Mammen, Joy; Marlar, Richard A.; Meley, Roland; Nair, Sukesh C.; Nichols, William L.; Raby, Anne; Reverter, Joan C.; Srivastava, Alok; Walker, Isobel

    2018-01-01

    Laboratory quality programs rely on internal quality control and external quality assessment (EQA). EQA programs provide unknown specimens for the laboratory to test. The laboratory's result is compared with other (peer) laboratories performing the same test. EQA programs assign target values using a variety of methods statistical tools and performance assessment of ‘pass’ or ‘fail’ is made. EQA provider members of the international organization, external quality assurance in thrombosis and hemostasis, took part in a study to compare outcome of performance analysis using the same data set of laboratory results. Eleven EQA organizations using eight different analytical approaches participated. Data for a normal and prolonged activated partial thromboplastin time (aPTT) and a normal and reduced factor VIII (FVIII) from 218 laboratories were sent to the EQA providers who analyzed the data set using their method of evaluation for aPTT and FVIII, determining the performance for each laboratory record in the data set. Providers also summarized their statistical approach to assignment of target values and laboratory performance. Each laboratory record in the data set was graded pass/fail by all EQA providers for each of the four analytes. There was a lack of agreement of pass/fail grading among EQA programs. Discordance in the grading was 17.9 and 11% of normal and prolonged aPTT results, respectively, and 20.2 and 17.4% of normal and reduced FVIII results, respectively. All EQA programs in this study employed statistical methods compliant with the International Standardization Organization (ISO), ISO 13528, yet the evaluation of laboratory results for all four analytes showed remarkable grading discordance. PMID:29232255

  16. Assessment of quality of life in patients with laryngeal cancer: A review of articles.

    PubMed

    Kolator, Mateusz; Kolator, Patrycja; Zatoński, Tomasz

    2018-04-19

    This article presents a review of the medical literature published between 1994 and 2014 with the use of the PubMed database concerning quality-of-life instruments for head and neck cancer patients used to assess general well-being of patients with laryngeal cancer. The PubMed database was searched for articles containing the keywords "quality of life", "laryngeal neoplasm" and "questionnaires". The resulting articles were reviewed and analyzed. After the identification of questionnaires, an additional search was performed. The articles and questionnaires were described and analyzed. In 43 articles, the authors used questionnaires specific to the head and neck regions in order to assess the quality of life in patients with laryngeal cancer. Four different questionnaires were identified. The European Organization for Research and Treatment of Cancer (EORTC) questionnaire is most commonly used to assess the quality of life in patients with laryngeal cancer. Questionnaires are generally used in order to select from a range of different treatment methods. There are a few head and neck cancer-related quality-of-life instruments which are widely used to assess the quality of life in patients with laryngeal cancer, but they are not dedicated to that region of the body. Today, there is much more attention paid to the quality of life; therefore, there is a real need to develop specific scales for different types of cancer.

  17. Assessing the influence of component processing and donor characteristics on quality of red cell concentrates using quality control data.

    PubMed

    Jordan, A; Chen, D; Yi, Q-L; Kanias, T; Gladwin, M T; Acker, J P

    2016-07-01

    Quality control (QC) data collected by blood services are used to monitor production and to ensure compliance with regulatory standards. We demonstrate how analysis of quality control data can be used to highlight the sources of variability within red cell concentrates (RCCs). We merged Canadian Blood Services QC data with manufacturing and donor records for 28 227 RCC between June 2011 and October 2014. Units were categorized based on processing method, bag manufacturer, donor age and donor sex, then assessed based on product characteristics: haemolysis and haemoglobin levels, unit volume, leucocyte count and haematocrit. Buffy-coat method (top/bottom)-processed units exhibited lower haemolysis than units processed using the whole-blood filtration method (top/top). Units from female donors exhibited lower haemolysis than male donations. Processing method influenced unit volume and the ratio of additive solution to residual plasma. Stored red blood cell characteristics are influenced by prestorage processing and donor factors. Understanding the relationship between processing, donors and RCC quality will help blood services to ensure the safety of transfused products. © 2016 International Society of Blood Transfusion.

  18. Comparability of river quality assessment using macrophytes: a multi-step procedure to overcome biogeographical differences.

    PubMed

    Aguiar, F C; Segurado, P; Urbanič, G; Cambra, J; Chauvin, C; Ciadamidaro, S; Dörflinger, G; Ferreira, J; Germ, M; Manolaki, P; Minciardi, M R; Munné, A; Papastergiadou, E; Ferreira, M T

    2014-04-01

    This paper exposes a new methodological approach to solve the problem of intercalibrating river quality national methods when a common metric is lacking and most of the countries share the same Water Framework Directive (WFD) assessment method. We provide recommendations for similar works in future concerning the assessment of ecological accuracy and highlight the importance of a good common ground to make feasible the scientific work beyond the intercalibration. The approach herein presented was applied to highly seasonal rivers of the Mediterranean Geographical Intercalibration Group for the Biological Quality Element Macrophytes. The Mediterranean Group of river macrophytes involved seven countries and two assessment methods with similar acquisition data and assessment concept: the Macrophyte Biological Index for Rivers (IBMR) for Cyprus, France, Greece, Italy, Portugal and Spain, and the River Macrophyte Index (RMI) for Slovenia. Database included 318 sites of which 78 were considered as benchmarks. The boundary harmonization was performed for common WFD-assessment methods (all countries except Slovenia) using the median of the Good/Moderate and High/Good boundaries of all countries. Then, whenever possible, the Slovenian method, RMI was computed for the entire database. The IBMR was also computed for the Slovenian sites and was regressed against RMI in order to check the relatedness of methods (R(2)=0.45; p<0.00001) and to convert RMI boundaries into the IBMR scale. The boundary bias of RMI was computed using direct comparison of classification and the median boundary values following boundary harmonization. The average absolute class differences after harmonization is 26% and the percentage of classifications differing by half of a quality class is also small (16.4%). This multi-step approach to the intercalibration was endorsed by the WFD Regulatory Committee. © 2013 Elsevier B.V. All rights reserved.

  19. Systematic review and quality assessment of cost-effectiveness analysis of pharmaceutical therapies for advanced colorectal cancer.

    PubMed

    Leung, Henry W C; Chan, Agnes L F; Leung, Matthew S H; Lu, Chin-Li

    2013-04-01

    To systematically review and assess the quality of cost-effectiveness analyses (CEAs) of pharmaceutical therapies for metastatic colorectal cancer (mCRC). The MEDLINE, EMBASE, Cochrane, and EconLit databases were searched for the Medical Subject Headings or text key words quality-adjusted, QALY, life-year gained (LYG), and cost-effectiveness (January 1, 1999-December 31, 2009). Original CEAs of mCRC pharmacotherapy published in English were included. CEAs that measured health effects in units other than quality-adjusted life years or LYG and letters to the editor, case reports, posters, and editorials were excluded. Each article was independently assessed by 2 trained reviewers according to a quality checklist created by the Panel on Cost-Effectiveness in Health and Medicine. Twenty-four CEA studies pertaining to pharmaceutical therapies for mCRC were identified. All studies showed a wide variation in methodologic approaches, which resulted in a different range of incremental cost-effectiveness ratios reported for each regimen. We found common methodologic flaws in a significant number of CEA studies, including lack of clear description for critique of data quality; lack of method for adjusting costs for inflation and methods for obtaining expert judgment; no results of model validation; wide differences in the types of perspective, time horizon, study design, cost categories, and effect outcomes; and no quality assessment of data (cost and effectiveness) for the interventions evaluation. This study has shown a wide variation in the methodology and quality of cost-effectiveness analysis for mCRC. Improving quality and harmonization of CEA for cancer treatment is needed. Further study is suggested to assess the quality of CEA methodology outside the mCRC disease state.

  20. Image quality assessment for selfies with and without super resolution

    NASA Astrophysics Data System (ADS)

    Kubota, Aya; Gohshi, Seiichi

    2018-04-01

    With the advent of cellphone cameras, in particular, on smartphones, many people now take photos of themselves alone and with others in the frame; such photos are popularly known as "selfies". Most smartphones are equipped with two cameras: the front-facing and rear cameras. The camera located on the back of the smartphone is referred to as the "out-camera," whereas the one located on the front of the smartphone is called the "in-camera." In-cameras are mainly used for selfies. Some smartphones feature high-resolution cameras. However, the original image quality cannot be obtained because smartphone cameras often have low-performance lenses. Super resolution (SR) is one of the recent technological advancements that has increased image resolution. We developed a new SR technology that can be processed on smartphones. Smartphones with new SR technology are currently available in the market have already registered sales. However, the effective use of new SR technology has not yet been verified. Comparing the image quality with and without SR on smartphone display is necessary to confirm the usefulness of this new technology. Methods that are based on objective and subjective assessments are required to quantitatively measure image quality. It is known that the typical object assessment value, such as Peak Signal to Noise Ratio (PSNR), does not go together with how we feel when we assess image/video. When digital broadcast started, the standard was determined using subjective assessment. Although subjective assessment usually comes at high cost because of personnel expenses for observers, the results are highly reproducible when they are conducted under right conditions and statistical analysis. In this study, the subjective assessment results for selfie images are reported.

  1. Assessing early unplanned reoperations in neurosurgery: opportunities for quality improvement.

    PubMed

    McLaughlin, Nancy; Jin, Peng; Martin, Neil A

    2015-07-01

    Review of morbidities and mortality has been the primary method used to assess surgical quality by physicians, hospitals, and oversight agencies. The incidence of reoperation has been proposed as a candidate quality indicator for surgical care. The authors report a comprehensive assessment of reoperations within a neurosurgical department and discuss how such data can be integrated into quality improvement initiatives to optimize value of care delivery. All neurosurgical procedures performed in the main operating room or the outpatient surgery center at the Ronald Reagan UCLA Medical Center and UCLA Santa Monica Medical Center from July 2008 to December 2012 were considered for this study. Interventional radiology and stereotactic radiosurgery procedures were excluded. Early reoperations within 7 days of the index surgery were reviewed and their preventability status was evaluated. The incidence of early unplanned reoperation was 2.6% (occurring after 183 of 6912 procedures). More than half of the patients who underwent early unplanned reoperation initially had surgery for shunt-related conditions (34.4%) or intracranial tumor (23.5%). Shunt failure was the most common indication for early unplanned reoperation (34.4%), followed by postoperative bleeding (20.8%) and postoperative elevated intracranial pressure (9.8%). The average time interval (± SD) between the index surgery and reoperation was 3.0 ± 1.9 days. The average length of stay following reoperation was 12.1 ± 14.4 days. This study enabled an in-depth assessment of reoperations within an academic neurosurgical practice and identification of strategic opportunities for department-wide quality improvement initiatives. The authors provide a nuanced discussion regarding the use of absolute reoperations as a quality indicator for neurosurgical patient populations.

  2. Academics' Perceptions on the Purposes of Quality Assessment

    ERIC Educational Resources Information Center

    Rosa, Maria J.; Sarrico, Claudia S.; Amaral, Alberto

    2012-01-01

    The accountability versus improvement debate is an old one. Although being traditionally considered dichotomous purposes of higher education quality assessment, some authors defend the need of balancing both in quality assessment systems. This article goes a step further and contends that not only they should be balanced but also that other…

  3. A framework for assessing Health Economic Evaluation (HEE) quality appraisal instruments.

    PubMed

    Langer, Astrid

    2012-08-16

    Health economic evaluations support the health care decision-making process by providing information on costs and consequences of health interventions. The quality of such studies is assessed by health economic evaluation (HEE) quality appraisal instruments. At present, there is no instrument for measuring and improving the quality of such HEE quality appraisal instruments. Therefore, the objectives of this study are to establish a framework for assessing the quality of HEE quality appraisal instruments to support and improve their quality, and to apply this framework to those HEE quality appraisal instruments which have been subject to more scrutiny than others, in order to test the framework and to demonstrate the shortcomings of existing HEE quality appraisal instruments. To develop the quality assessment framework for HEE quality appraisal instruments, the experiences of using appraisal tools for clinical guidelines are used. Based on a deductive iterative process, clinical guideline appraisal instruments identified through literature search are reviewed, consolidated, and adapted to produce the final quality assessment framework for HEE quality appraisal instruments. The final quality assessment framework for HEE quality appraisal instruments consists of 36 items organized within 7 dimensions, each of which captures a specific domain of quality. Applying the quality assessment framework to four existing HEE quality appraisal instruments, it is found that these four quality appraisal instruments are of variable quality. The framework described in this study should be regarded as a starting point for appraising the quality of HEE quality appraisal instruments. This framework can be used by HEE quality appraisal instrument producers to support and improve the quality and acceptance of existing and future HEE quality appraisal instruments. By applying this framework, users of HEE quality appraisal instruments can become aware of methodological deficiencies

  4. A Critical Analysis of Assessment Quality in Genomics and Bioinformatics Education Research

    PubMed Central

    Campbell, Chad E.; Nehm, Ross H.

    2013-01-01

    The growing importance of genomics and bioinformatics methods and paradigms in biology has been accompanied by an explosion of new curricula and pedagogies. An important question to ask about these educational innovations is whether they are having a meaningful impact on students’ knowledge, attitudes, or skills. Although assessments are necessary tools for answering this question, their outputs are dependent on their quality. Our study 1) reviews the central importance of reliability and construct validity evidence in the development and evaluation of science assessments and 2) examines the extent to which published assessments in genomics and bioinformatics education (GBE) have been developed using such evidence. We identified 95 GBE articles (out of 226) that contained claims of knowledge increases, affective changes, or skill acquisition. We found that 1) the purpose of most of these studies was to assess summative learning gains associated with curricular change at the undergraduate level, and 2) a minority (<10%) of studies provided any reliability or validity evidence, and only one study out of the 95 sampled mentioned both validity and reliability. Our findings raise concerns about the quality of evidence derived from these instruments. We end with recommendations for improving assessment quality in GBE. PMID:24006400

  5. Advanced Computational Methods for High-accuracy Refinement of Protein Low-quality Models

    NASA Astrophysics Data System (ADS)

    Zang, Tianwu

    Predicting the 3-dimentional structure of protein has been a major interest in the modern computational biology. While lots of successful methods can generate models with 3˜5A root-mean-square deviation (RMSD) from the solution, the progress of refining these models is quite slow. It is therefore urgently needed to develop effective methods to bring low-quality models to higher-accuracy ranges (e.g., less than 2 A RMSD). In this thesis, I present several novel computational methods to address the high-accuracy refinement problem. First, an enhanced sampling method, named parallel continuous simulated tempering (PCST), is developed to accelerate the molecular dynamics (MD) simulation. Second, two energy biasing methods, Structure-Based Model (SBM) and Ensemble-Based Model (EBM), are introduced to perform targeted sampling around important conformations. Third, a three-step method is developed to blindly select high-quality models along the MD simulation. These methods work together to make significant refinement of low-quality models without any knowledge of the solution. The effectiveness of these methods is examined in different applications. Using the PCST-SBM method, models with higher global distance test scores (GDT_TS) are generated and selected in the MD simulation of 18 targets from the refinement category of the 10th Critical Assessment of Structure Prediction (CASP10). In addition, in the refinement test of two CASP10 targets using the PCST-EBM method, it is indicated that EBM may bring the initial model to even higher-quality levels. Furthermore, a multi-round refinement protocol of PCST-SBM improves the model quality of a protein to the level that is sufficient high for the molecular replacement in X-ray crystallography. Our results justify the crucial position of enhanced sampling in the protein structure prediction and demonstrate that a considerable improvement of low-accuracy structures is still achievable with current force fields.

  6. Objective assessment of MPEG-2 video quality

    NASA Astrophysics Data System (ADS)

    Gastaldo, Paolo; Zunino, Rodolfo; Rovetta, Stefano

    2002-07-01

    The increasing use of video compression standards in broadcasting television systems has required, in recent years, the development of video quality measurements that take into account artifacts specifically caused by digital compression techniques. In this paper we present a methodology for the objective quality assessment of MPEG video streams by using circular back-propagation feedforward neural networks. Mapping neural networks can render nonlinear relationships between objective features and subjective judgments, thus avoiding any simplifying assumption on the complexity of the model. The neural network processes an instantaneous set of input values, and yields an associated estimate of perceived quality. Therefore, the neural-network approach turns objective quality assessment into adaptive modeling of subjective perception. The objective features used for the estimate are chosen according to the assessed relevance to perceived quality and are continuously extracted in real time from compressed video streams. The overall system mimics perception but does not require any analytical model of the underlying physical phenomenon. The capability to process compressed video streams represents an important advantage over existing approaches, like avoiding the stream-decoding process greatly enhances real-time performance. Experimental results confirm that the system provides satisfactory, continuous-time approximations for actual scoring curves concerning real test videos.

  7. A method to establish seismic noise baselines for automated station assessment

    USGS Publications Warehouse

    McNamara, D.E.; Hutt, C.R.; Gee, L.S.; Benz, H.M.; Buland, R.P.

    2009-01-01

    We present a method for quantifying station noise baselines and characterizing the spectral shape of out-of-nominal noise sources. Our intent is to automate this method in order to ensure that only the highest-quality data are used in rapid earthquake products at NEIC. In addition, the station noise baselines provide a valuable tool to support the quality control of GSN and ANSS backbone data and metadata. The procedures addressed here are currently in development at the NEIC, and work is underway to understand how quickly changes from nominal can be observed and used within the NEIC processing framework. The spectral methods and software used to compute station baselines and described herein (PQLX) can be useful to both permanent and portable seismic stations operators. Applications include: general seismic station and data quality control (QC), evaluation of instrument responses, assessment of near real-time communication system performance, characterization of site cultural noise conditions, and evaluation of sensor vault design, as well as assessment of gross network capabilities (McNamara et al. 2005). Future PQLX development plans include incorporating station baselines for automated QC methods and automating station status report generation and notification based on user-defined QC parameters. The PQLX software is available through the USGS (http://earthquake. usgs.gov/research/software/pqlx.php) and IRIS (http://www.iris.edu/software/ pqlx/).

  8. Blind image quality assessment via probabilistic latent semantic analysis.

    PubMed

    Yang, Xichen; Sun, Quansen; Wang, Tianshu

    2016-01-01

    We propose a blind image quality assessment that is highly unsupervised and training free. The new method is based on the hypothesis that the effect caused by distortion can be expressed by certain latent characteristics. Combined with probabilistic latent semantic analysis, the latent characteristics can be discovered by applying a topic model over a visual word dictionary. Four distortion-affected features are extracted to form the visual words in the dictionary: (1) the block-based local histogram; (2) the block-based local mean value; (3) the mean value of contrast within a block; (4) the variance of contrast within a block. Based on the dictionary, the latent topics in the images can be discovered. The discrepancy between the frequency of the topics in an unfamiliar image and a large number of pristine images is applied to measure the image quality. Experimental results for four open databases show that the newly proposed method correlates well with human subjective judgments of diversely distorted images.

  9. Quality assessment of remote sensing image fusion using feature-based fourth-order correlation coefficient

    NASA Astrophysics Data System (ADS)

    Ma, Dan; Liu, Jun; Chen, Kai; Li, Huali; Liu, Ping; Chen, Huijuan; Qian, Jing

    2016-04-01

    In remote sensing fusion, the spatial details of a panchromatic (PAN) image and the spectrum information of multispectral (MS) images will be transferred into fused images according to the characteristics of the human visual system. Thus, a remote sensing image fusion quality assessment called feature-based fourth-order correlation coefficient (FFOCC) is proposed. FFOCC is based on the feature-based coefficient concept. Spatial features related to spatial details of the PAN image and spectral features related to the spectrum information of MS images are first extracted from the fused image. Then, the fourth-order correlation coefficient between the spatial and spectral features is calculated and treated as the assessment result. FFOCC was then compared with existing widely used indices, such as Erreur Relative Globale Adimensionnelle de Synthese, and quality assessed with no reference. Results of the fusion and distortion experiments indicate that the FFOCC is consistent with subjective evaluation. FFOCC significantly outperforms the other indices in evaluating fusion images that are produced by different fusion methods and that are distorted in spatial and spectral features by blurring, adding noise, and changing intensity. All the findings indicate that the proposed method is an objective and effective quality assessment for remote sensing image fusion.

  10. Research on assessment and improvement method of remote sensing image reconstruction

    NASA Astrophysics Data System (ADS)

    Sun, Li; Hua, Nian; Yu, Yanbo; Zhao, Zhanping

    2018-01-01

    Remote sensing image quality assessment and improvement is an important part of image processing. Generally, the use of compressive sampling theory in remote sensing imaging system can compress images while sampling which can improve efficiency. A method of two-dimensional principal component analysis (2DPCA) is proposed to reconstruct the remote sensing image to improve the quality of the compressed image in this paper, which contain the useful information of image and can restrain the noise. Then, remote sensing image quality influence factors are analyzed, and the evaluation parameters for quantitative evaluation are introduced. On this basis, the quality of the reconstructed images is evaluated and the different factors influence on the reconstruction is analyzed, providing meaningful referential data for enhancing the quality of remote sensing images. The experiment results show that evaluation results fit human visual feature, and the method proposed have good application value in the field of remote sensing image processing.

  11. Higher quality of molecular testing, an unfulfilled priority: Results from external quality assessment for KRAS mutation testing in colorectal cancer.

    PubMed

    Tembuyser, Lien; Ligtenberg, Marjolijn J L; Normanno, Nicola; Delen, Sofie; van Krieken, J Han; Dequeker, Elisabeth M C

    2014-05-01

    Precision medicine is now a key element in clinical oncology. RAS mutational status is a crucial predictor of responsiveness to anti-epidermal growth factor receptor agents in metastatic colorectal cancer. In an effort to guarantee high-quality testing services in molecular pathology, the European Society of Pathology has been organizing an annual KRAS external quality assessment program since 2009. In 2012, 10 formalin-fixed, paraffin-embedded samples, of which 8 from invasive metastatic colorectal cancer tissue and 2 artificial samples of cell line material, were sent to more than 100 laboratories from 26 countries with a request for routine KRAS testing. Both genotyping and clinical reports were assessed independently. Twenty-seven percent of the participants genotyped at least 1 of 10 samples incorrectly. In total, less than 5% of the distributed specimens were genotyped incorrectly. Genotyping errors consisted of false negatives, false positives, and incorrectly genotyped mutations. Twenty percent of the laboratories reported a technical error for one or more samples. A review of the written reports showed that several essential elements were missing, most notably a clinical interpretation of the test result, the method sensitivity, and the use of a reference sequence. External quality assessment serves as a valuable educational tool in assessing and improving molecular testing quality and is an important asset for monitoring quality assurance upon incorporation of new biomarkers in diagnostic services. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  12. Specific guidelines for assessing and improving the methodological quality of economic evaluations of newborn screening

    PubMed Central

    2012-01-01

    Background Economic evaluation of newborn screening poses specific methodological challenges. Amongst others, these challenges refer to the use of quality adjusted life years (QALYs) in newborns, and which costs and outcomes need to be considered in a full evaluation of newborn screening programmes. Because of the increasing scale and scope of such programmes, a better understanding of the methods of high-quality economic evaluations may be crucial for both producers/authors and consumers/reviewers of newborn screening-related economic evaluations. The aim of this study was therefore to develop specific guidelines designed to assess and improve the methodological quality of economic evaluations in newborn screening. Methods To develop the guidelines, existing guidelines for assessing the quality of economic evaluations were identified through a literature search, and were reviewed and consolidated using a deductive iterative approach. In a subsequent test phase, these guidelines were applied to various economic evaluations which acted as case studies. Results The guidelines for assessing and improving the methodological quality of economic evaluations in newborn screening are organized into 11 categories: “bibliographic details”, “study question and design”, “modelling”, “health outcomes”, “costs”, “discounting”, “presentation of results”, “sensitivity analyses”, “discussion”, “conclusions”, and “commentary”. Conclusions The application of the guidelines highlights important issues regarding newborn screening-related economic evaluations, and underscores the need for such issues to be afforded greater consideration in future economic evaluations. The variety in methodological quality detected by this study reveals the need for specific guidelines on the appropriate methods for conducting sound economic evaluations in newborn screening. PMID:22947299

  13. MASQOT: a method for cDNA microarray spot quality control

    PubMed Central

    Bylesjö, Max; Eriksson, Daniel; Sjödin, Andreas; Sjöström, Michael; Jansson, Stefan; Antti, Henrik; Trygg, Johan

    2005-01-01

    Background cDNA microarray technology has emerged as a major player in the parallel detection of biomolecules, but still suffers from fundamental technical problems. Identifying and removing unreliable data is crucial to prevent the risk of receiving illusive analysis results. Visual assessment of spot quality is still a common procedure, despite the time-consuming work of manually inspecting spots in the range of hundreds of thousands or more. Results A novel methodology for cDNA microarray spot quality control is outlined. Multivariate discriminant analysis was used to assess spot quality based on existing and novel descriptors. The presented methodology displays high reproducibility and was found superior in identifying unreliable data compared to other evaluated methodologies. Conclusion The proposed methodology for cDNA microarray spot quality control generates non-discrete values of spot quality which can be utilized as weights in subsequent analysis procedures as well as to discard spots of undesired quality using the suggested threshold values. The MASQOT approach provides a consistent assessment of spot quality and can be considered an alternative to the labor-intensive manual quality assessment process. PMID:16223442

  14. Quality assessment of Penthorum chinense Pursh through multicomponent qualification and fingerprint, chemometric, and antihepatocarcinoma analyses.

    PubMed

    Sun, Zong-Liang; Zhang, Yu-Zhen; Zhang, Feng; Zhang, Jia-Wei; Zheng, Guo-Can; Tan, Ling; Wang, Chong-Zhi; Zhou, Lian-Di; Zhang, Qi-Hui; Yuan, Chun-Su

    2018-06-22

    An efficient method combined with fingerprint and chemometric analyses was developed to evaluate the quality of the traditional Chinese medicine plant Penthorum chinense Pursh. Nine samples were collected from different regions during different harvest periods, and 17 components in the form of extracts were simultaneously examined to assess quality by using high-performance liquid chromatography. The hepatoprotective effects of components were investigated by assessing the inhibition of SMMC-7721 cell growth. The results indicated that the quality control method was accurate, stable, and reliable, and the hierarchical heat-map cluster and the principle component analyses confirmed that the classification of all nine samples was consistent. Quercetin and ellagitannins including pinocembrin-7-O-[3''-O-galloyl-4'',6''-hexahydroxydiphenoyl]-β-glucose (PGHG), thonningianin A, thonningianin B, and other flavonoids were abundant in the extracts, and significantly contributed to the hepatoprotective effects.

  15. Key Elements for Judging the Quality of a Risk Assessment

    PubMed Central

    Fenner-Crisp, Penelope A.; Dellarco, Vicki L.

    2016-01-01

    Background: Many reports have been published that contain recommendations for improving the quality, transparency, and usefulness of decision making for risk assessments prepared by agencies of the U.S. federal government. A substantial measure of consensus has emerged regarding the characteristics that high-quality assessments should possess. Objective: The goal was to summarize the key characteristics of a high-quality assessment as identified in the consensus-building process and to integrate them into a guide for use by decision makers, risk assessors, peer reviewers and other interested stakeholders to determine if an assessment meets the criteria for high quality. Discussion: Most of the features cited in the guide are applicable to any type of assessment, whether it encompasses one, two, or all four phases of the risk-assessment paradigm; whether it is qualitative or quantitative; and whether it is screening level or highly sophisticated and complex. Other features are tailored to specific elements of an assessment. Just as agencies at all levels of government are responsible for determining the effectiveness of their programs, so too should they determine the effectiveness of their assessments used in support of their regulatory decisions. Furthermore, if a nongovernmental entity wishes to have its assessments considered in the governmental regulatory decision-making process, then these assessments should be judged in the same rigorous manner and be held to similar standards. Conclusions: The key characteristics of a high-quality assessment can be summarized and integrated into a guide for judging whether an assessment possesses the desired features of high quality, transparency, and usefulness. Citation: Fenner-Crisp PA, Dellarco VL. 2016. Key elements for judging the quality of a risk assessment. Environ Health Perspect 124:1127–1135; http://dx.doi.org/10.1289/ehp.1510483 PMID:26862984

  16. Quality Evaluation of Raw Moutan Cortex Using the AHP and Gray Correlation-TOPSIS Method

    PubMed Central

    Zhou, Sujuan; Liu, Bo; Meng, Jiang

    2017-01-01

    Background: Raw Moutan cortex (RMC) is an important Chinese herbal medicine. Comprehensive and objective quality evaluation of Chinese herbal medicine has been one of the most important issues in the modern herbs development. Objective: To evaluate and compare the quality of RMC using the weighted gray correlation- Technique for Order Preference by Similarity to an Ideal Solution (TOPSIS) method. Materials and Methods: The percentage composition of gallic acid, catechin, oxypaeoniflorin, paeoniflorin, quercetin, benzoylpaeoniflorin, paeonol in different batches of RMC was determined, and then adopting MATLAB programming to construct the gray correlation-TOPSIS assessment model for quality evaluation of RMC. Results: The quality evaluation results of model evaluation and objective evaluation were consistent, reliable, and stable. Conclusion: The model of gray correlation-TOPSIS can be well applied to the quality evaluation of traditional Chinese medicine with multiple components and has broad prospect in application. SUMMARY The experiment tries to construct a model to evaluate the quality of RMC using the weighted gray correlation- Technique for Order Preference by Similarity to an Ideal Solution (TOPSIS) method. Results show the model is reliable and provide a feasible way in evaluating quality of traditional Chinese medicine with multiple components. PMID:28839384

  17. A comparison of methods for the assessment of odor impacts on air quality: Field inspection (VDI 3940) and the air dispersion model CALPUFF

    NASA Astrophysics Data System (ADS)

    Ranzato, Laura; Barausse, Alberto; Mantovani, Alice; Pittarello, Alberto; Benzo, Maurizio; Palmeri, Luca

    2012-12-01

    Unpleasant odors are a major cause of public complaints concerning air quality and represent a growing social problem in industrialized countries. However, the assessment of odor pollution is still regarded as a difficult task, because olfactory nuisance can be caused by many different chemical compounds, often found in hard-to-detect concentrations, and the perception of odors is influenced by subjective thresholds; moreover, the impact of odor sources on air quality is mediated by complex atmospheric dispersion processes. The development of standardized assessment approaches to odor pollution and proper international regulatory tools are urgently needed. In particular, comparisons of the methodologies commonly used nowadays to assess odor impacts on air quality are required. Here, we assess the olfactory nuisance caused by an anaerobic treatment plant for municipal solid waste by means of two alternative techniques: the field inspection procedure and the atmospheric dispersion model CALPUFF. Our goal was to compare rigorously their estimates of odor nuisance, both qualitatively (spatial extent of odor impact) and quantitatively (intensity of odor nuisance). To define the impact of odors, we referred to the German standards, based on the frequency of odor episodes in terms of odor hours. We report a satisfying, although not perfect agreement between the estimates provided by the two techniques. For example, they assessed similar spatial extents of odor pollution, but different frequencies of odor episodes in locations where the odor nuisance was highest. The comparison highlights strengths and weaknesses for both approaches. CALPUFF is a cheaper methodology which can be used predictively, but fugitive emissions are difficult to model reliably, because of uncertainty regarding timing, location and emission rate. Field inspection takes into account the role of human perception, but unlike the model it does not always characterize precisely the extent of the odor

  18. Student's Perceptions of Quality Learning in a Malaysian University--A Mixed Method Approach

    ERIC Educational Resources Information Center

    Choy, S. Chee; Yim, Joanne Sau-Ching; Tan, Poh Leong

    2017-01-01

    Purpose: This paper aims to examine students' perceptions of quality learning using a mixed-methods approach in a Malaysian university, with an aim to fill existing knowledge gaps in the literature on relationships among relevant quality variables. The study also assesses the extent to which detailed results from a few participants can be…

  19. A scientifically based nationwide assessment of groundwater quality in the United States

    USGS Publications Warehouse

    Alley, W.M.; Cohen, P.

    1991-01-01

    Beginning in 1986, the U.S. Geological Survey began an effort to develop a National Water-Quality Assessment Program. The basic premise underlying this initiative is that a better understanding of the quality of water resources across the country, both surface- and groundwater, is needed to develop effective programs and policies to meet the nation's water-quality concerns. The program will focus on water-quality conditions that are prevalent or large in scale, such as occur from nonpoint sources of pollution or from a high density of point sources. The design of the program is substantially different from the traditional approach of a diffuse national monitoring network. The major activities of the assessment program will be clustered within a set of hydrologic systems (river basins and aquifer systems), referred to as study units. In aggregate, the study units will account for a large part of the nation's water use and represent a wide range of settings across the country. Unique attributes of the program include: (1) the use of consistent study approaches, field and laboratory methods, water-quality measurements, and ancillary data measurements for all study units; (2) the development of a progressive understanding of water-quality conditions and trends in each study unit through long-term studies that rotate periods of intensive data collection and analysis with periods during which the assessment activities are less intensive; and (3) the focus of considerable effort on synthesizing results from among the study units to provide information on regional and national water-quality issues. ?? 1991 Springer-Verlag New York Inc.

  20. Image quality assessment of automatic three-segment MR attenuation correction vs. CT attenuation correction.

    PubMed

    Partovi, Sasan; Kohan, Andres; Gaeta, Chiara; Rubbert, Christian; Vercher-Conejero, Jose L; Jones, Robert S; O'Donnell, James K; Wojtylak, Patrick; Faulhaber, Peter

    2013-01-01

    The purpose of this study is to systematically evaluate the usefulness of Positron emission tomography/Magnetic resonance imaging (PET/MRI) images in a clinical setting by assessing the image quality of Positron emission tomography (PET) images using a three-segment MR attenuation correction (MRAC) versus the standard CT attenuation correction (CTAC). We prospectively studied 48 patients who had their clinically scheduled FDG-PET/CT followed by an FDG-PET/MRI. Three nuclear radiologists evaluated the image quality of CTAC vs. MRAC using a Likert scale (five-point scale). A two-sided, paired t-test was performed for comparison purposes. The image quality was further assessed by categorizing it as acceptable (equal to 4 and 5 on the five-point Likert scale) or unacceptable (equal to 1, 2, and 3 on the five-point Likert scale) quality using the McNemar test. When assessing the image quality using the Likert scale, one reader observed a significant difference between CTAC and MRAC (p=0.0015), whereas the other readers did not observe a difference (p=0.8924 and p=0.1880, respectively). When performing the grouping analysis, no significant difference was found between CTAC vs. MRAC for any of the readers (p=0.6137 for reader 1, p=1 for reader 2, and p=0.8137 for reader 3). All three readers more often reported artifacts on the MRAC images than on the CTAC images. There was no clinically significant difference in quality between PET images generated on a PET/MRI system and those from a Positron emission tomography/Computed tomography (PET/CT) system. PET images using the automatic three-segmented MR attenuation method provided diagnostic image quality. However, future research regarding the image quality obtained using different MR attenuation based methods is warranted before PET/MRI can be used clinically.

  1. Herbal hepatotoxicity: Challenges and pitfalls of causality assessment methods

    PubMed Central

    Teschke, Rolf; Frenzel, Christian; Schulze, Johannes; Eickhoff, Axel

    2013-01-01

    The diagnosis of herbal hepatotoxicity or herb induced liver injury (HILI) represents a particular clinical and regulatory challenge with major pitfalls for the causality evaluation. At the day HILI is suspected in a patient, physicians should start assessing the quality of the used herbal product, optimizing the clinical data for completeness, and applying the Council for International Organizations of Medical Sciences (CIOMS) scale for initial causality assessment. This scale is structured, quantitative, liver specific, and validated for hepatotoxicity cases. Its items provide individual scores, which together yield causality levels of highly probable, probable, possible, unlikely, and excluded. After completion by additional information including raw data, this scale with all items should be reported to regulatory agencies and manufacturers for further evaluation. The CIOMS scale is preferred as tool for assessing causality in hepatotoxicity cases, compared to numerous other causality assessment methods, which are inferior on various grounds. Among these disputed methods are the Maria and Victorino scale, an insufficiently qualified, shortened version of the CIOMS scale, as well as various liver unspecific methods such as the ad hoc causality approach, the Naranjo scale, the World Health Organization (WHO) method, and the Karch and Lasagna method. An expert panel is required for the Drug Induced Liver Injury Network method, the WHO method, and other approaches based on expert opinion, which provide retrospective analyses with a long delay and thereby prevent a timely assessment of the illness in question by the physician. In conclusion, HILI causality assessment is challenging and is best achieved by the liver specific CIOMS scale, avoiding pitfalls commonly observed with other approaches. PMID:23704820

  2. Communication after laryngectomy: an assessment of quality of life.

    PubMed

    Carr, M M; Schmidbauer, J A; Majaess, L; Smith, R L

    2000-01-01

    The purpose of this study was to examine quality of life in laryngectomees using different methods of communication. A survey was mailed to all the living laryngectomees in Nova Scotia. Patients were asked to rate their ability to communicate in a number of common situations, to rate their difficulty with several communication problems, and to complete the EORTC QLQ-C30 quality-of-life assessment tool. Sixty-two patients responded (return rate of 84%); 57% were using electrolaryngeal speech, 19% esophageal speech, and 8.5% tracheoesophageal speech. These groups were comparable with respect to age, sex, first language, education level, and years since laryngectomy. There were very few differences between these groups in ability to communicate in social situations and no difference in overall quality of life as measured by these scales. The most commonly cited problem was difficulty being heard in a noisy environment. Despite the fact that tracheoesophageal speech is objectively most intelligible, there does not seem to be a measurable improvement in quality of life or ability to communicate in everyday situations over electrolaryngeal or esophageal speakers.

  3. Published methodological quality of randomized controlled trials does not reflect the actual quality assessed in protocols

    PubMed Central

    Mhaskar, Rahul; Djulbegovic, Benjamin; Magazin, Anja; Soares, Heloisa P.; Kumar, Ambuj

    2011-01-01

    Objectives To assess whether reported methodological quality of randomized controlled trials (RCTs) reflect the actual methodological quality, and to evaluate the association of effect size (ES) and sample size with methodological quality. Study design Systematic review Setting Retrospective analysis of all consecutive phase III RCTs published by 8 National Cancer Institute Cooperative Groups until year 2006. Data were extracted from protocols (actual quality) and publications (reported quality) for each study. Results 429 RCTs met the inclusion criteria. Overall reporting of methodological quality was poor and did not reflect the actual high methodological quality of RCTs. The results showed no association between sample size and actual methodological quality of a trial. Poor reporting of allocation concealment and blinding exaggerated the ES by 6% (ratio of hazard ratio [RHR]: 0.94, 95%CI: 0.88, 0.99) and 24% (RHR: 1.24, 95%CI: 1.05, 1.43), respectively. However, actual quality assessment showed no association between ES and methodological quality. Conclusion The largest study to-date shows poor quality of reporting does not reflect the actual high methodological quality. Assessment of the impact of quality on the ES based on reported quality can produce misleading results. PMID:22424985

  4. Headspace screening: A novel approach for fast quality assessment of the essential oil from culinary sage.

    PubMed

    Cvetkovikj, Ivana; Stefkov, Gjoshe; Acevska, Jelena; Karapandzova, Marija; Dimitrovska, Aneta; Kulevanova, Svetlana

    2016-07-01

    Quality assessment of essential oil (EO) from culinary sage (Salvia officinalis L., Lamiaceae) is limited by the long pharmacopoeial procedure. The aim of this study was to employ headspace (HS) sampling in the quality assessment of sage EO. Different populations (30) of culinary sage were assessed using GC/FID/MS analysis of the hydrodistilled EO (pharmacopoeial method) and HS sampling directly from leaves. Compound profiles from both procedures were evaluated according to ISO 9909 and GDC standards for sage EO quality, revealing compliance for only 10 populations. Factors to convert HS values, for the target ISO and GDC components, into theoretical EO values were calculated. Statistical analysis revealed a significant relationship between HS and EO values for seven target components. Consequently, HS sampling could be used as a complementary extraction technique for rapid screening in quality assessment of sage EOs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Portfolios: An Alternative Method of Student and Program Assessment

    PubMed Central

    Hannam, Susan E.

    1995-01-01

    The use of performance-based evaluation and alternative assessment techniques has become essential for curriculum programs seeking Commission of Accreditation of Allied Health Education Programs (CAAHEP) accreditation. In athletic training education, few assessment models exist to assess student performance over the entire course of their educational program. This article describes a model of assessment-a student athletic training portfolio of “best works.” The portfolio can serve as a method to assess student development and to assess program effectiveness. The goals of the program include purposes specific to the five NATA performance domains. In addition, four types of portfolio evidence are described: artifacts, attestations, productions, and reproductions. Quality assignments and projects completed by students as they progress through a six-semester program are identified relative to the type of evidence and the domain(s) they represent. The portfolio assists with student development, provides feedback for curriculum planning, allows for student/faculty collaboration and “coaching” of the student, and assists with job searching. This information will serve as a useful model for those athletic training programs looking for an alternative method of assessing student and program outcomes. PMID:16558359

  6. Q-SEA – a tool for quality assessment of ethics analyses conducted as part of health technology assessments

    PubMed Central

    Scott, Anna Mae; Hofmann, Björn; Gutiérrez-Ibarluzea, Iñaki; Bakke Lysdahl, Kristin; Sandman, Lars; Bombard, Yvonne

    2017-01-01

    Introduction: Assessment of ethics issues is an important part of health technology assessments (HTA). However, in terms of existence of quality assessment tools, ethics for HTA is methodologically underdeveloped in comparison to other areas of HTA, such as clinical or cost effectiveness. Objective: To methodologically advance ethics for HTA by: (1) proposing and elaborating Q-SEA, the first instrument for quality assessment of ethics analyses, and (2) applying Q-SEA to a sample systematic review of ethics for HTA, in order to illustrate and facilitate its use. Methods: To develop a list of items for the Q-SEA instrument, we systematically reviewed the literature on methodology in ethics for HTA, reviewed HTA organizations’ websites, and solicited views from 32 experts in the field of ethics for HTA at two 2-day workshops. We subsequently refined Q-SEA through its application to an ethics analysis conducted for HTA. Results: Q-SEA instrument consists of two domains – the process domain and the output domain. The process domain consists of 5 elements: research question, literature search, inclusion/exclusion criteria, perspective, and ethics framework. The output domain consists of 5 elements: completeness, bias, implications, conceptual clarification, and conflicting values. Conclusion: Q-SEA is the first instrument for quality assessment of ethics analyses in HTA. Further refinements to the instrument to enhance its usability continue. PMID:28326147

  7. Electrical impedance spectroscopy for quality assessment of meat and fish: A review on basic principles, measurement methods, and recent advances

    USDA-ARS?s Scientific Manuscript database

    Electrical impedance spectroscopy (EIS), as an effective analytical technique for electrochemical system, has shown a wide application for food quality and safety assessment recently. Individual differences of livestock cause high variation in quality of raw meat and fish and their commercialized pr...

  8. Balance quality assessment as an early indicator of physical frailty in older people.

    PubMed

    Chkeir, Aly; Safieddine, Doha; Bera, D; Collart, M; Novella, J L; Drame, M; Hewson, David J; Duchene, Jacques

    2016-08-01

    Frailty is an increasingly common geriatric condition that results in an increased risk of adverse health outcomes such as falls. The most widely-used means of detecting frailty is the Fried phenotype, which includes several objective measures such as grip strength and gait velocity. One method of screening for falls is to measure balance, which can be done by a range of techniques including the assessment of the Centre of Pressure (CoP) during a balance assessment. The Balance Quality Tester (BQT) is a device based on a commercial bathroom scale that can evaluate balance quality. The BQT provides instantaneously the position of the CoP (stabilogram) in both anteroposterior (AP) and mediolateral (ML) directions and can estimate the vertical ground reaction force. The purpose of this study was to examine the relationship between balance quality assessment and physical frailty. Balance quality was compared to physical frailty in 186 older subjects. Rising rate (RR) was slower and trajectory velocity (TV) was higher in subjects classified as frail for both grip strength and gait velocity (p<;0.05). Balance assessment could be used in conjunction with functional tests of grip strength and gait velocity as a means of screening for frailty.

  9. Surgical quality assessment. A simplified approach.

    PubMed

    DeLong, D L

    1991-10-01

    The current approach to QA primarily involves taking action when problems are discovered and designing a documentation system that records the deliverance of quality care. Involving the entire staff helps eliminate problems before they occur. By keeping abreast of current problems and soliciting input from staff members, the QA at our hospital has improved dramatically. The cross-referencing of JCAHO and AORN standards on the assessment form and the single-sheet reporting form expedite the evaluation process and simplify record keeping. The bulletin board increases staff members' understanding of QA and boosts morale and participation. A sound and effective QA program does not require reorganizing an entire department, nor should it invoke negative connotations. Developing an effective QA program merely requires rethinking current processes. The program must meet the department's specific needs, and although many departments concentrate on documentation, auditing charts does not give a complete picture of the quality of care delivered. The QA committee must employ a variety of data collection methods on multiple indicators to ensure an accurate representation of the care delivered, and they must not overlook any issues that directly affect patient outcomes.

  10. Non-invasive Fetal ECG Signal Quality Assessment for Multichannel Heart Rate Estimation.

    PubMed

    Andreotti, Fernando; Graser, Felix; Malberg, Hagen; Zaunseder, Sebastian

    2017-12-01

    The noninvasive fetal ECG (NI-FECG) from abdominal recordings offers novel prospects for prenatal monitoring. However, NI-FECG signals are corrupted by various nonstationary noise sources, making the processing of abdominal recordings a challenging task. In this paper, we present an online approach that dynamically assess the quality of NI-FECG to improve fetal heart rate (FHR) estimation. Using a naive Bayes classifier, state-of-the-art and novel signal quality indices (SQIs), and an existing adaptive Kalman filter, FHR estimation was improved. For the purpose of training and validating the proposed methods, a large annotated private clinical dataset was used. The suggested classification scheme demonstrated an accuracy of Krippendorff's alpha in determining the overall quality of NI-FECG signals. The proposed Kalman filter outperformed alternative methods for FHR estimation achieving accuracy. The proposed algorithm was able to reliably reflect changes of signal quality and can be used in improving FHR estimation. NI-ECG signal quality estimation and multichannel information fusion are largely unexplored topics. Based on previous works, multichannel FHR estimation is a field that could strongly benefit from such methods. The developed SQI algorithms as well as resulting classifier were made available under a GNU GPL open-source license and contributed to the FECGSYN toolbox.

  11. Postgraduate Education in Quality Improvement Methods: Initial Results of the Fellows' Applied Quality Training (FAQT) Curriculum.

    PubMed

    Winchester, David E; Burkart, Thomas A; Choi, Calvin Y; McKillop, Matthew S; Beyth, Rebecca J; Dahm, Phillipp

    2016-06-01

    Training in quality improvement (QI) is a pillar of the next accreditation system of the Accreditation Committee on Graduate Medical Education and a growing expectation of physicians for maintenance of certification. Despite this, many postgraduate medical trainees are not receiving training in QI methods. We created the Fellows Applied Quality Training (FAQT) curriculum for cardiology fellows using both didactic and applied components with the goal of increasing confidence to participate in future QI projects. Fellows completed didactic training from the Institute for Healthcare Improvement's Open School and then designed and completed a project to improve quality of care or patient safety. Self-assessments were completed by the fellows before, during, and after the first year of the curriculum. The primary outcome for our curriculum was the median score reported by the fellows regarding their self-confidence to complete QI activities. Self-assessments were completed by 23 fellows. The majority of fellows (15 of 23, 65.2%) reported no prior formal QI training. Median score on baseline self-assessment was 3.0 (range, 1.85-4), which was significantly increased to 3.27 (range, 2.23-4; P = 0.004) on the final assessment. The distribution of scores reported by the fellows indicates that 30% were slightly confident at conducting QI activities on their own, which was reduced to 5% after completing the FAQT curriculum. An interim assessment was conducted after the fellows completed didactic training only; median scores were not different from the baseline (mean, 3.0; P = 0.51). After completion of the FAQT, cardiology fellows reported higher self-confidence to complete QI activities. The increase in self-confidence seemed to be limited to the applied component of the curriculum, with no significant change after the didactic component.

  12. Constructing Ecological Networks Based on Habitat Quality Assessment: A Case Study of Changzhou, China

    PubMed Central

    Gao, Yu; Ma, Lei; Liu, Jiaxun; Zhuang, Zhuzhou; Huang, Qiuhao; Li, Manchun

    2017-01-01

    Fragmentation and reduced continuity of habitat patches threaten the environment and biodiversity. Recently, ecological networks are increasingly attracting the attention of researchers as they provide fundamental frameworks for environmental protection. This study suggests a set of procedures to construct an ecological network. First, we proposed a method to construct a landscape resistance surface based on the assessment of habitat quality. Second, to analyze the effect of the resistance surface on corridor simulations, we used three methods to construct resistance surfaces: (1) the method proposed in this paper, (2) the entropy coefficient method, and (3) the expert scoring method. Then, we integrated habitat patches and resistance surfaces to identify potential corridors using graph theory. These procedures were tested in Changzhou, China. Comparing the outputs of using different resistance surfaces demonstrated that: (1) different landscape resistance surfaces contribute to how corridors are identified, but only slightly affect the assessment of the importance of habitat patches and potential corridors; (2) the resistance surface, which is constructed based on habitat quality, is more applicable to corridor simulations; and (3) the assessment of the importance of habitat patches is fundamental for ecological network optimization in the conservation of critical habitat patches and corridors. PMID:28393879

  13. [Quality control assessments of feces examination for schistosomiasis in province-level laboratories of Zhejiang Province].

    PubMed

    Chen, Wen; Zhu, Ming-Dong; Yan, Xiao-Lan; Lin, Li-Jun; Zhang, Jian-Feng; Li, Li; Wen, Li-Yong

    2011-06-01

    To understand and evaluate the quality of feces examination for schistosomiasis in province-level laboratories of Zhejiang Province. With the single-blind method, the stool samples were detected by the stool hatching method and sediment detection method. In the 3 quality control assessments in 2006, 2008 and 2009, most laboratories finished the examinations on time. The accordance rates of detections were 88.9%, 100% and 93.9%, respectively. The province-level laboratories for schistosomiasis feces examination of Zhejiang Province is coming into standardization, and the techniques of schistosomiasis feces examination are optimized gradually.

  14. A Novel Unsupervised Segmentation Quality Evaluation Method for Remote Sensing Images

    PubMed Central

    Tang, Yunwei; Jing, Linhai; Ding, Haifeng

    2017-01-01

    The segmentation of a high spatial resolution remote sensing image is a critical step in geographic object-based image analysis (GEOBIA). Evaluating the performance of segmentation without ground truth data, i.e., unsupervised evaluation, is important for the comparison of segmentation algorithms and the automatic selection of optimal parameters. This unsupervised strategy currently faces several challenges in practice, such as difficulties in designing effective indicators and limitations of the spectral values in the feature representation. This study proposes a novel unsupervised evaluation method to quantitatively measure the quality of segmentation results to overcome these problems. In this method, multiple spectral and spatial features of images are first extracted simultaneously and then integrated into a feature set to improve the quality of the feature representation of ground objects. The indicators designed for spatial stratified heterogeneity and spatial autocorrelation are included to estimate the properties of the segments in this integrated feature set. These two indicators are then combined into a global assessment metric as the final quality score. The trade-offs of the combined indicators are accounted for using a strategy based on the Mahalanobis distance, which can be exhibited geometrically. The method is tested on two segmentation algorithms and three testing images. The proposed method is compared with two existing unsupervised methods and a supervised method to confirm its capabilities. Through comparison and visual analysis, the results verified the effectiveness of the proposed method and demonstrated the reliability and improvements of this method with respect to other methods. PMID:29064416

  15. E-Services quality assessment framework for collaborative networks

    NASA Astrophysics Data System (ADS)

    Stegaru, Georgiana; Danila, Cristian; Sacala, Ioan Stefan; Moisescu, Mihnea; Mihai Stanescu, Aurelian

    2015-08-01

    In a globalised networked economy, collaborative networks (CNs) are formed to take advantage of new business opportunities. Collaboration involves shared resources and capabilities, such as e-Services that can be dynamically composed to automate CN participants' business processes. Quality is essential for the success of business process automation. Current approaches mostly focus on quality of service (QoS)-based service selection and ranking algorithms, overlooking the process of service composition which requires interoperable, adaptable and secure e-Services to ensure seamless collaboration, data confidentiality and integrity. Lack of assessment of these quality attributes can result in e-Service composition failure. The quality of e-Service composition relies on the quality of each e-Service and on the quality of the composition process. Therefore, there is the need for a framework that addresses quality from both views: product and process. We propose a quality of e-Service composition (QoESC) framework for quality assessment of e-Service composition for CNs which comprises of a quality model for e-Service evaluation and guidelines for quality of e-Service composition process. We implemented a prototype considering a simplified telemedicine use case which involves a CN in e-Healthcare domain. To validate the proposed quality-driven framework, we analysed service composition reliability with and without using the proposed framework.

  16. Assessing the effects of regional payment for watershed services program on water quality using an intervention analysis model.

    PubMed

    Lu, Yan; He, Tian

    2014-09-15

    Much attention has been recently paid to ex-post assessments of socioeconomic and environmental benefits of payment for ecosystem services (PES) programs on poverty reduction, water quality, and forest protection. To evaluate the effects of a regional PES program on water quality, we selected chemical oxygen demand (COD) and ammonia-nitrogen (NH3-N) as indicators of water quality. Statistical methods and an intervention analysis model were employed to assess whether the PES program produced substantial changes in water quality at 10 water-quality sampling stations in the Shaying River watershed, China during 2006-2011. Statistical results from paired-sample t-tests and box plots of COD and NH3-N concentrations at the 10 stations showed that the PES program has played a positive role in improving water quality and reducing trans-boundary water pollution in the Shaying River watershed. Using the intervention analysis model, we quantitatively evaluated the effects of the intervention policy, i.e., the watershed PES program, on water quality at the 10 stations. The results suggest that this method could be used to assess the environmental benefits of watershed or water-related PES programs, such as improvements in water quality, seasonal flow regulation, erosion and sedimentation, and aquatic habitat. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Demand assessment and price-elasticity estimation of quality-improved primary health care in Palestine: a contribution from the contingent valuation method.

    PubMed

    Mataria, Awad; Luchini, Stéphane; Daoud, Yousef; Moatti, Jean-Paul

    2007-10-01

    This paper proposes a new methodology to assess demand and price-elasticity for health care, based on patients' stated willingness to pay (WTP) values for certain aspects of health care quality improvements. A conceptual analysis of how respondents consider contingent valuation (CV) questions allowed us to specify a probability density function of stated WTP values, and consequently, to model a demand function for quality-improved health care, using a parametric survival approach. The model was empirically estimated using a CV study intended to assess patients' values for improving the quality of primary health care (PHC) services in Palestine. A random sample of 499 individuals was interviewed following medical consultation in four PHC centers. Quality was assessed using a multi-attribute approach; and respondents valued seven specific quality improvements using a decomposed valuation scenario and a payment card elicitation technique. Our results suggest an inelastic demand at low user fees levels, and when the price-increase is accompanied with substantial quality-improvements. Nevertheless, demand becomes more and more elastic if user fees continue to rise. On the other hand, patients' reactions to price-increase turn out to depend on their level of income. Our results can be used to design successful health care financing strategies that include a consideration of patients' preferences and financial capacities. John Wiley & Sons, Ltd.

  18. A novel method of assessing quality of postgraduate psychiatry training: experiences from a large training programme.

    PubMed

    Bizrah, Mukhtar; Iacoponi, Eduardo; Parker, Elizabeth; Rymer, Janice; Iversen, Amy; Wessely, Simon

    2013-06-14

    Most assessments of the quality of postgraduate training are based on anonymised questionnaires of trainees. We report a comprehensive assessment of the quality of training at a large postgraduate psychiatry training institute using non-anonymised face-to-face interviews with trainees and their trainers. Two consultant psychiatrists interviewed 99 trainees and 109 trainers. Scoring of interview responses was determined by using a pre-defined criteria. Additional comments were recorded as free text. Interviews covered 13 domains, including: Clinical, teaching, research and management opportunities, clinical environment, clinical supervision, adequacy of job description, absence of bullying and job satisfaction. Multiple interview domain scores were combined, generating a 'Combined' score for each post. The interview response rate was 97% for trainers 88% for trainees. There was a significant correlation between trainee and trainer scores for the same interview domains (Pearson's r = 0.968, p< 0.001). Overall scores were significantly higher for specialist psychiatry posts as compared to general adult psychiatry posts (Two tailed t-test, p < 0.001, 95% CI: -0.398 to -0.132), and significantly higher for liaison psychiatry as compared to other specialist psychiatry posts (t-test: p = 0.038, 95% CI: -0.3901, -0.0118). Job satisfaction scores of year 1 to year 3 core trainees showed a significant increase with increasing seniority (Linear regression coefficient = 0.273, 95% CI: 0.033 to 0.513, ANOVA p= 0.026). This in-depth examination of the quality of training on a large psychiatry training programme successfully elicited strengths and weakness of our programme. Such an interview scheme could be easily implemented in smaller schemes and may well provide important information to allow for targeted improvement of training. Additionally, trends in quality of training and job satisfaction amongst various psychiatric specialities were identified; specifically speciality

  19. Correlation Between Resonance Frequency Analysis and Bone Quality Assessments at Dental Implant Recipient Sites.

    PubMed

    Fu, Min-Wen; Fu, Earl; Lin, Fu-Gong; Chang, Wei-Jeng; Hsieh, Yao-Dung; Shen, E-Chin

    To evaluate whether primary implant stability could be used to predict bone quality, the association between the implant stability quotient (ISQ) value and the bone type at the implant site was evaluated. Ninety-five implant sites in 50 patients were included. Bone type (categorized by Lekholm and Zarb) at the implant site was initially assessed using presurgical dental radiography. During the preparation of the implant site, a bone core specimen was carefully obtained. The bone type was assessed by tactile sensation during the drilling operation, according to the Misch criteria. The primary stability of the inserted implant was evaluated by resonance frequency analysis (RFA). The ISQ value was recorded. The bone core specimen was then examined by stereomicroscopy or microcomputed tomography (micro-CT), and the bone type was determined by the surface characteristics of the specimen, based on Lekholm and Zarb classification. Agreement between the bone quality assessed by the four methods (ie, presurgical radiography, tactile sensation, stereomicroscopy, and micro-CT) was tested by Cohen's kappa statistics, whereas the association between the ISQ value and the bone type was evaluated by the generalized linear regression model. The mean ISQ score was 72.6, and the score was significantly influenced by the maxillary or mandibular arch (P = .001). The bone type at the implant sites varied according to the assessment method. However, a significant influence of the arch was repeatedly noted when using radiography or tactile sensation. Among the four bone-quality assessment methods, a weak agreement existed only between stereomicroscopy and micro-CT, especially in the maxilla (κ = 0.469). A negative association between the ISQ value and the bone type assessed by stereomicroscopy or by micro-CT was significant in the maxilla, but not in the mandible, after adjustments for sex, age, and right/left side (P = .013 and P = .027 for stereomicroscopy and micro-CT, respectively

  20. ProQ3: Improved model quality assessments using Rosetta energy terms

    PubMed Central

    Uziela, Karolis; Shu, Nanjiang; Wallner, Björn; Elofsson, Arne

    2016-01-01

    Quality assessment of protein models using no other information than the structure of the model itself has been shown to be useful for structure prediction. Here, we introduce two novel methods, ProQRosFA and ProQRosCen, inspired by the state-of-art method ProQ2, but using a completely different description of a protein model. ProQ2 uses contacts and other features calculated from a model, while the new predictors are based on Rosetta energies: ProQRosFA uses the full-atom energy function that takes into account all atoms, while ProQRosCen uses the coarse-grained centroid energy function. The two new predictors also include residue conservation and terms corresponding to the agreement of a model with predicted secondary structure and surface area, as in ProQ2. We show that the performance of these predictors is on par with ProQ2 and significantly better than all other model quality assessment programs. Furthermore, we show that combining the input features from all three predictors, the resulting predictor ProQ3 performs better than any of the individual methods. ProQ3, ProQRosFA and ProQRosCen are freely available both as a webserver and stand-alone programs at http://proq3.bioinfo.se/. PMID:27698390

  1. Abstract analysis method facilitates filtering low-methodological quality and high-bias risk systematic reviews on psoriasis interventions.

    PubMed

    Gómez-García, Francisco; Ruano, Juan; Aguilar-Luque, Macarena; Alcalde-Mellado, Patricia; Gay-Mimbrera, Jesús; Hernández-Romero, José Luis; Sanz-Cabanillas, Juan Luis; Maestre-López, Beatriz; González-Padilla, Marcelino; Carmona-Fernández, Pedro J; García-Nieto, Antonio Vélez; Isla-Tejera, Beatriz

    2017-12-29

    Article summaries' information and structure may influence researchers/clinicians' decisions to conduct deeper full-text analyses. Specifically, abstracts of systematic reviews (SRs) and meta-analyses (MA) should provide structured summaries for quick assessment. This study explored a method for determining the methodological quality and bias risk of full-text reviews using abstract information alone. Systematic literature searches for SRs and/or MA about psoriasis were undertaken on MEDLINE, EMBASE, and Cochrane database. For each review, quality, abstract-reporting completeness, full-text methodological quality, and bias risk were evaluated using Preferred Reporting Items for Systematic Reviews and Meta-analyses for abstracts (PRISMA-A), Assessing the Methodological Quality of Systematic Reviews (AMSTAR), and ROBIS tools, respectively. Article-, author-, and journal-derived metadata were systematically extracted from eligible studies using a piloted template, and explanatory variables concerning abstract-reporting quality were assessed using univariate and multivariate-regression models. Two classification models concerning SRs' methodological quality and bias risk were developed based on per-item and total PRISMA-A scores and decision-tree algorithms. This work was supported, in part, by project ICI1400136 (JR). No funding was received from any pharmaceutical company. This study analysed 139 SRs on psoriasis interventions. On average, they featured 56.7% of PRISMA-A items. The mean total PRISMA-A score was significantly higher for high-methodological-quality SRs than for moderate- and low-methodological-quality reviews. SRs with low-bias risk showed higher total PRISMA-A values than reviews with high-bias risk. In the final model, only 'authors per review > 6' (OR: 1.098; 95%CI: 1.012-1.194), 'academic source of funding' (OR: 3.630; 95%CI: 1.788-7.542), and 'PRISMA-endorsed journal' (OR: 4.370; 95%CI: 1.785-10.98) predicted PRISMA-A variability. Reviews with a

  2. Assessing primary care data quality.

    PubMed

    Lim, Yvonne Mei Fong; Yusof, Maryati; Sivasampu, Sheamini

    2018-04-16

    Purpose The purpose of this paper is to assess National Medical Care Survey data quality. Design/methodology/approach Data completeness and representativeness were computed for all observations while other data quality measures were assessed using a 10 per cent sample from the National Medical Care Survey database; i.e., 12,569 primary care records from 189 public and private practices were included in the analysis. Findings Data field completion ranged from 69 to 100 per cent. Error rates for data transfer from paper to web-based application varied between 0.5 and 6.1 per cent. Error rates arising from diagnosis and clinical process coding were higher than medication coding. Data fields that involved free text entry were more prone to errors than those involving selection from menus. The authors found that completeness, accuracy, coding reliability and representativeness were generally good, while data timeliness needs to be improved. Research limitations/implications Only data entered into a web-based application were examined. Data omissions and errors in the original questionnaires were not covered. Practical implications Results from this study provided informative and practicable approaches to improve primary health care data completeness and accuracy especially in developing nations where resources are limited. Originality/value Primary care data quality studies in developing nations are limited. Understanding errors and missing data enables researchers and health service administrators to prevent quality-related problems in primary care data.

  3. Reporting Quality Assessment of Randomized Controlled Trials Published in Nephrology Urology Monthly Journal.

    PubMed

    Mehrazmay, Alireza; Karambakhsh, Alireza; Salesi, Mahmood

    2015-07-01

    Randomized controlled trials (RCTs) are important tools for evidence-based health care decisions. It is, therefore, important that they be conducted and reported with the highest possible standards. The aim of this study was to evaluate the reporting quality of the RCTs published in nephrology urology monthly journal and to examine whether there was a change over time in the reporting quality. The quality of each report was assessed using the Consolidated Standards of Reporting Trials (CONSORT) 2010 Statement checklist and a 5-point quality assessment instrument, i.e. the Jadad scale. Eighteen (14 Iranian and 4 non-Iranian) RCTs were published from 2012 to 2014 on topics including renal stone (16.6%), hemodialysis and transplantation (38.8%), and prostate conditions (11.1%). Interventions comprised surgery, drugs, and teaching method in 7 (38 %), 10 (55%), and 1 (5%) of them, respectively. According to the CONSORT checklist, the weakest reported items were registration number, identification as a randomized trial in the title, and settings and locations where the data were collected. The mean Jadad score of the reports was 2.72 ± 1.36 (54% of their maximum possible total score). According to the Jadad and CONSORT scales, there was an increase in the quality of reporting from 2012 to 2014. This assessment shows low reporting quality scores in reports. Training courses for researchers, using standard reporting tools (e.g. CONSORT 2010 Statement checklist), and consultation with methodologists can improve the quality of published RCTs.

  4. Published methodological quality of randomized controlled trials does not reflect the actual quality assessed in protocols.

    PubMed

    Mhaskar, Rahul; Djulbegovic, Benjamin; Magazin, Anja; Soares, Heloisa P; Kumar, Ambuj

    2012-06-01

    To assess whether the reported methodological quality of randomized controlled trials (RCTs) reflects the actual methodological quality and to evaluate the association of effect size (ES) and sample size with methodological quality. Systematic review. This is a retrospective analysis of all consecutive phase III RCTs published by eight National Cancer Institute Cooperative Groups up to 2006. Data were extracted from protocols (actual quality) and publications (reported quality) for each study. Four hundred twenty-nine RCTs met the inclusion criteria. Overall reporting of methodological quality was poor and did not reflect the actual high methodological quality of RCTs. The results showed no association between sample size and actual methodological quality of a trial. Poor reporting of allocation concealment and blinding exaggerated the ES by 6% (ratio of hazard ratio [RHR]: 0.94; 95% confidence interval [CI]: 0.88, 0.99) and 24% (RHR: 1.24; 95% CI: 1.05, 1.43), respectively. However, actual quality assessment showed no association between ES and methodological quality. The largest study to date shows that poor quality of reporting does not reflect the actual high methodological quality. Assessment of the impact of quality on the ES based on reported quality can produce misleading results. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Quality assurance, benchmarking, assessment and mutual international recognition of qualifications.

    PubMed

    Hobson, R; Rolland, S; Rotgans, J; Schoonheim-Klein, M; Best, H; Chomyszyn-Gajewska, M; Dymock, D; Essop, R; Hupp, J; Kundzina, R; Love, R; Memon, R A; Moola, M; Neumann, L; Ozden, N; Roth, K; Samwel, P; Villavicencio, J; Wright, P; Harzer, W

    2008-02-01

    The aim of this report is to provide guidance to assist in the international convergence of quality assurance, benchmarking and assessment systems to improve dental education. Proposals are developed for mutual recognition of qualifications, to aid international movement and exchange of staff and students including and supporting developing countries. Quality assurance is the responsibility of all staff involved in dental education and involves three levels: internal, institutional and external. Benchmarking information provides a subject framework. Benchmarks are useful for a variety of purposes including design and validation of programmes, examination and review; they can also strengthen the accreditation process undertaken by professional and statutory bodies. Benchmark information can be used by institutions as part of their programme approval process, to set degree standards. The standards should be developed by the dental academic community through formal groups of experts. Assessment outcomes of student learning are a measure of the quality of the learning programme. The goal of an effective assessment strategy should be that it provides the starting point for students to adopt a positive approach to effective and competent practice, reflective and lifelong learning. All assessment methods should be evidence based or based upon research. Mutual recognition of professional qualifications means that qualifications gained in one country (the home country) are recognized in another country (the host country). It empowers movement of skilled workers, which can help resolve skills shortages within participating countries. These proposals are not intended to be either exhaustive or prescriptive; they are purely for guidance and derived from the identification of what is perceived to be 'best practice'.

  6. 42 CFR 460.136 - Internal quality assessment and performance improvement activities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Internal quality assessment and performance improvement activities. 460.136 Section 460.136 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES....136 Internal quality assessment and performance improvement activities. (a) Quality assessment and...

  7. 42 CFR 460.136 - Internal quality assessment and performance improvement activities.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... in quality assessment and performance improvement activities, including providing information about... 42 Public Health 4 2014-10-01 2014-10-01 false Internal quality assessment and performance...) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Quality Assessment and Performance Improvement § 460...

  8. 42 CFR 460.136 - Internal quality assessment and performance improvement activities.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... in quality assessment and performance improvement activities, including providing information about... 42 Public Health 4 2012-10-01 2012-10-01 false Internal quality assessment and performance...) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Quality Assessment and Performance Improvement § 460...

  9. 42 CFR 460.136 - Internal quality assessment and performance improvement activities.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... in quality assessment and performance improvement activities, including providing information about... 42 Public Health 4 2013-10-01 2013-10-01 false Internal quality assessment and performance...) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Quality Assessment and Performance Improvement § 460...

  10. Illinois Quality Counts: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Illinois' Quality Counts prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for Family…

  11. A new approach to subjectively assess quality of plenoptic content

    NASA Astrophysics Data System (ADS)

    Viola, Irene; Řeřábek, Martin; Ebrahimi, Touradj

    2016-09-01

    Plenoptic content is becoming increasingly popular thanks to the availability of acquisition and display devices. Thanks to image-based rendering techniques, a plenoptic content can be rendered in real time in an interactive manner allowing virtual navigation through the captured scenes. This way of content consumption enables new experiences, and therefore introduces several challenges in terms of plenoptic data processing, transmission and consequently visual quality evaluation. In this paper, we propose a new methodology to subjectively assess the visual quality of plenoptic content. We also introduce a prototype software to perform subjective quality assessment according to the proposed methodology. The proposed methodology is further applied to assess the visual quality of a light field compression algorithm. Results show that this methodology can be successfully used to assess the visual quality of plenoptic content.

  12. 42 CFR 493.1239 - Standard: General laboratory systems quality assessment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... of general laboratory systems quality assessment reviews with appropriate staff. (c) The laboratory must document all general laboratory systems quality assessment activities. [68 FR 3703, Jan. 24, 2003... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: General laboratory systems quality...

  13. Quality control in public participation assessments of water quality: the OPAL Water Survey.

    PubMed

    Rose, N L; Turner, S D; Goldsmith, B; Gosling, L; Davidson, T A

    2016-07-22

    Public participation in scientific data collection is a rapidly expanding field. In water quality surveys, the involvement of the public, usually as trained volunteers, generally includes the identification of aquatic invertebrates to a broad taxonomic level. However, quality assurance is often not addressed and remains a key concern for the acceptance of publicly-generated water quality data. The Open Air Laboratories (OPAL) Water Survey, launched in May 2010, aimed to encourage interest and participation in water science by developing a 'low-barrier-to-entry' water quality survey. During 2010, over 3000 participant-selected lakes and ponds were surveyed making this the largest public participation lake and pond survey undertaken to date in the UK. But the OPAL approach of using untrained volunteers and largely anonymous data submission exacerbates quality control concerns. A number of approaches were used in order to address data quality issues including: sensitivity analysis to determine differences due to operator, sampling effort and duration; direct comparisons of identification between participants and experienced scientists; the use of a self-assessment identification quiz; the use of multiple participant surveys to assess data variability at single sites over short periods of time; comparison of survey techniques with other measurement variables and with other metrics generally considered more accurate. These quality control approaches were then used to screen the OPAL Water Survey data to generate a more robust dataset. The OPAL Water Survey results provide a regional and national assessment of water quality as well as a first national picture of water clarity (as suspended solids concentrations). Less than 10 % of lakes and ponds surveyed were 'poor' quality while 26.8 % were in the highest water quality band. It is likely that there will always be a question mark over untrained volunteer generated data simply because quality assurance is uncertain

  14. Statistical approaches used to assess and redesign surface water-quality-monitoring networks.

    PubMed

    Khalil, B; Ouarda, T B M J

    2009-11-01

    An up-to-date review of the statistical approaches utilized for the assessment and redesign of surface water quality monitoring (WQM) networks is presented. The main technical aspects of network design are covered in four sections, addressing monitoring objectives, water quality variables, sampling frequency and spatial distribution of sampling locations. This paper discusses various monitoring objectives and related procedures used for the assessment and redesign of long-term surface WQM networks. The appropriateness of each approach for the design, contraction or expansion of monitoring networks is also discussed. For each statistical approach, its advantages and disadvantages are examined from a network design perspective. Possible methods to overcome disadvantages and deficiencies in the statistical approaches that are currently in use are recommended.

  15. Assessment Quality and Practices in Secondary PE in the Netherlands

    ERIC Educational Resources Information Center

    Borghouts, Lars B.; Slingerland, Menno; Haerens, Leen

    2017-01-01

    Background: Assessment can have various functions, and is an important impetus for student learning. For assessment to be effective, it should be aligned with curriculum goals and of sufficient quality. Although it has been suggested that assessment quality in physical education (PE) is suboptimal, research into actual assessment practices has…

  16. The quality of instruments to assess the process of shared decision making: A systematic review

    PubMed Central

    Bomhof-Roordink, Hanna; Smith, Ian P.; Scholl, Isabelle; Stiggelbout, Anne M.; Pieterse, Arwen H.

    2018-01-01

    Objective To inventory instruments assessing the process of shared decision making and appraise their measurement quality, taking into account the methodological quality of their validation studies. Methods In a systematic review we searched seven databases (PubMed, Embase, Emcare, Cochrane, PsycINFO, Web of Science, Academic Search Premier) for studies investigating instruments measuring the process of shared decision making. Per identified instrument, we assessed the level of evidence separately for 10 measurement properties following a three-step procedure: 1) appraisal of the methodological quality using the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN) checklist, 2) appraisal of the psychometric quality of the measurement property using three possible quality scores, 3) best-evidence synthesis based on the number of studies, their methodological and psychometrical quality, and the direction and consistency of the results. The study protocol was registered at PROSPERO: CRD42015023397. Results We included 51 articles describing the development and/or evaluation of 40 shared decision-making process instruments: 16 patient questionnaires, 4 provider questionnaires, 18 coding schemes and 2 instruments measuring multiple perspectives. There is an overall lack of evidence for their measurement quality, either because validation is missing or methods are poor. The best-evidence synthesis indicated positive results for a major part of instruments for content validity (50%) and structural validity (53%) if these were evaluated, but negative results for a major part of instruments when inter-rater reliability (47%) and hypotheses testing (59%) were evaluated. Conclusions Due to the lack of evidence on measurement quality, the choice for the most appropriate instrument can best be based on the instrument’s content and characteristics such as the perspective that they assess. We recommend refinement and validation of

  17. Doctors or technicians: assessing quality of medical education

    PubMed Central

    Hasan, Tayyab

    2010-01-01

    Medical education institutions usually adapt industrial quality management models that measure the quality of the process of a program but not the quality of the product. The purpose of this paper is to analyze the impact of industrial quality management models on medical education and students, and to highlight the importance of introducing a proper educational quality management model. Industrial quality management models can measure the training component in terms of competencies, but they lack the educational component measurement. These models use performance indicators to assess their process improvement efforts. Researchers suggest that the performance indicators used in educational institutions may only measure their fiscal efficiency without measuring the quality of the educational experience of the students. In most of the institutions, where industrial models are used for quality assurance, students are considered as customers and are provided with the maximum services and facilities possible. Institutions are required to fulfill a list of recommendations from the quality control agencies in order to enhance student satisfaction and to guarantee standard services. Quality of medical education should be assessed by measuring the impact of the educational program and quality improvement procedures in terms of knowledge base development, behavioral change, and patient care. Industrial quality models may focus on academic support services and processes, but educational quality models should be introduced in parallel to focus on educational standards and products. PMID:23745059

  18. Doctors or technicians: assessing quality of medical education.

    PubMed

    Hasan, Tayyab

    2010-01-01

    Medical education institutions usually adapt industrial quality management models that measure the quality of the process of a program but not the quality of the product. The purpose of this paper is to analyze the impact of industrial quality management models on medical education and students, and to highlight the importance of introducing a proper educational quality management model. Industrial quality management models can measure the training component in terms of competencies, but they lack the educational component measurement. These models use performance indicators to assess their process improvement efforts. Researchers suggest that the performance indicators used in educational institutions may only measure their fiscal efficiency without measuring the quality of the educational experience of the students. In most of the institutions, where industrial models are used for quality assurance, students are considered as customers and are provided with the maximum services and facilities possible. Institutions are required to fulfill a list of recommendations from the quality control agencies in order to enhance student satisfaction and to guarantee standard services. Quality of medical education should be assessed by measuring the impact of the educational program and quality improvement procedures in terms of knowledge base development, behavioral change, and patient care. Industrial quality models may focus on academic support services and processes, but educational quality models should be introduced in parallel to focus on educational standards and products.

  19. Large-scale model quality assessment for improving protein tertiary structure prediction.

    PubMed

    Cao, Renzhi; Bhattacharya, Debswapna; Adhikari, Badri; Li, Jilong; Cheng, Jianlin

    2015-06-15

    Sampling structural models and ranking them are the two major challenges of protein structure prediction. Traditional protein structure prediction methods generally use one or a few quality assessment (QA) methods to select the best-predicted models, which cannot consistently select relatively better models and rank a large number of models well. Here, we develop a novel large-scale model QA method in conjunction with model clustering to rank and select protein structural models. It unprecedentedly applied 14 model QA methods to generate consensus model rankings, followed by model refinement based on model combination (i.e. averaging). Our experiment demonstrates that the large-scale model QA approach is more consistent and robust in selecting models of better quality than any individual QA method. Our method was blindly tested during the 11th Critical Assessment of Techniques for Protein Structure Prediction (CASP11) as MULTICOM group. It was officially ranked third out of all 143 human and server predictors according to the total scores of the first models predicted for 78 CASP11 protein domains and second according to the total scores of the best of the five models predicted for these domains. MULTICOM's outstanding performance in the extremely competitive 2014 CASP11 experiment proves that our large-scale QA approach together with model clustering is a promising solution to one of the two major problems in protein structure modeling. The web server is available at: http://sysbio.rnet.missouri.edu/multicom_cluster/human/. © The Author 2015. Published by Oxford University Press.

  20. Measurement properties of existing clinical assessment methods evaluating scapular positioning and function. A systematic review.

    PubMed

    Larsen, Camilla Marie; Juul-Kristensen, Birgit; Lund, Hans; Søgaard, Karen

    2014-10-01

    The aims were to compile a schematic overview of clinical scapular assessment methods and critically appraise the methodological quality of the involved studies. A systematic, computer-assisted literature search using Medline, CINAHL, SportDiscus and EMBASE was performed from inception to October 2013. Reference lists in articles were also screened for publications. From 50 articles, 54 method names were identified and categorized into three groups: (1) Static positioning assessment (n = 19); (2) Semi-dynamic (n = 13); and (3) Dynamic functional assessment (n = 22). Fifteen studies were excluded for evaluation due to no/few clinimetric results, leaving 35 studies for evaluation. Graded according to the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN checklist), the methodological quality in the reliability and validity domains was "fair" (57%) to "poor" (43%), with only one study rated as "good". The reliability domain was most often investigated. Few of the assessment methods in the included studies that had "fair" or "good" measurement property ratings demonstrated acceptable results for both reliability and validity. We found a substantially larger number of clinical scapular assessment methods than previously reported. Using the COSMIN checklist the methodological quality of the included measurement properties in the reliability and validity domains were in general "fair" to "poor". None were examined for all three domains: (1) reliability; (2) validity; and (3) responsiveness. Observational evaluation systems and assessment of scapular upward rotation seem suitably evidence-based for clinical use. Future studies should test and improve the clinimetric properties, and especially diagnostic accuracy and responsiveness, to increase utility for clinical practice.

  1. The role of optical flow in automated quality assessment of full-motion video

    NASA Astrophysics Data System (ADS)

    Harguess, Josh; Shafer, Scott; Marez, Diego

    2017-09-01

    In real-world video data, such as full-motion-video (FMV) taken from unmanned vehicles, surveillance systems, and other sources, various corruptions to the raw data is inevitable. This can be due to the image acquisition process, noise, distortion, and compression artifacts, among other sources of error. However, we desire methods to analyze the quality of the video to determine whether the underlying content of the corrupted video can be analyzed by humans or machines and to what extent. Previous approaches have shown that motion estimation, or optical flow, can be an important cue in automating this video quality assessment. However, there are many different optical flow algorithms in the literature, each with their own advantages and disadvantages. We examine the effect of the choice of optical flow algorithm (including baseline and state-of-the-art), on motionbased automated video quality assessment algorithms.

  2. Environmental quality assessment of groundwater resources in Al Jabal Al Akhdar, Sultanate of Oman

    NASA Astrophysics Data System (ADS)

    Al-Kalbani, Mohammed Saif; Price, Martin F.; Ahmed, Mushtaque; Abahussain, Asma; O'Higgins, Timothy

    2017-11-01

    The research was conducted to assess the quality of groundwater resources of Al Jabal Al Akhdar, Oman. 11 drinking water sources were sampled during summer and winter seasons during 2012-2013 to evaluate their physico-chemical quality indicators; and assess their suitability for drinking and other domestic purposes. Sample collection, handling and processing followed the standard methods recommended by APHA and analyzed in quality assured laboratories using appropriate analytical methods and instrumental techniques. The results show that the quality parameters in all drinking water resources are within the permissible limits set by Omani and WHO standards; and the drinking water quality index is good or medium in quality based on NFS-WQI classification criteria, indicating their suitability for human consumption. There is an indication of the presence of high nitrate concentrations in some groundwater wells, which require more investigations and monitoring program to be conducted on regular basis to ensure good quality water supply for the residents in the mountain. The trilinear Piper diagram shows that most of the drinking water resources of the study area fall in the field of calcium and bicarbonate type with some magnesium bicarbonate type indicating that most of the major ions are natural in origin due to the geology of the region. This study is a first step towards providing indicators on groundwater quality of this fragile mountain ecosystem, which will be the basis for future planning decisions on corrective demand management measures to protect groundwater resources of Al Jabal Al Akhdar.

  3. Southwest principal aquifers regional ground-water quality assessment

    USGS Publications Warehouse

    Anning, D.W.; Thiros, Susan A.; Bexfield, L.M.; McKinney, T.S.; Green, J.M.

    2009-01-01

    The National Water-Quality Assessment (NAWQA) Program of the U.S. Geological Survey is conducting a regional analysis of water quality in the principal aquifers in the southwestern United States. The Southwest Principal Aquifers (SWPA) study is building a better understanding of the susceptibility and vulnerability of basin-fill aquifers in the region to ground-water contamination by synthesizing the baseline knowledge of ground-water quality conditions in 15 basins previously studied by the NAWQA Program. The improved understanding of aquifer susceptibility and vulnerability to contamination is assisting in the development of tools that water managers can use to assess and protect the quality of ground-water resources. This fact sheet provides an overview of the basin-fill aquifers in the southwestern United States and description of the completed and planned regional analyses of ground-water quality being performed by the SWPA study.

  4. Electronic Quality of Life Assessment Using Computer-Adaptive Testing

    PubMed Central

    2016-01-01

    Background Quality of life (QoL) questionnaires are desirable for clinical practice but can be time-consuming to administer and interpret, making their widespread adoption difficult. Objective Our aim was to assess the performance of the World Health Organization Quality of Life (WHOQOL)-100 questionnaire as four item banks to facilitate adaptive testing using simulated computer adaptive tests (CATs) for physical, psychological, social, and environmental QoL. Methods We used data from the UK WHOQOL-100 questionnaire (N=320) to calibrate item banks using item response theory, which included psychometric assessments of differential item functioning, local dependency, unidimensionality, and reliability. We simulated CATs to assess the number of items administered before prespecified levels of reliability was met. Results The item banks (40 items) all displayed good model fit (P>.01) and were unidimensional (fewer than 5% of t tests significant), reliable (Person Separation Index>.70), and free from differential item functioning (no significant analysis of variance interaction) or local dependency (residual correlations < +.20). When matched for reliability, the item banks were between 45% and 75% shorter than paper-based WHOQOL measures. Across the four domains, a high standard of reliability (alpha>.90) could be gained with a median of 9 items. Conclusions Using CAT, simulated assessments were as reliable as paper-based forms of the WHOQOL with a fraction of the number of items. These properties suggest that these item banks are suitable for computerized adaptive assessment. These item banks have the potential for international development using existing alternative language versions of the WHOQOL items. PMID:27694100

  5. Objective Assessment of Image Quality VI: Imaging in Radiation Therapy

    PubMed Central

    Barrett, Harrison H.; Kupinski, Matthew A.; Müeller, Stefan; Halpern, Howard J.; Morris, John C.; Dwyer, Roisin

    2015-01-01

    Earlier work on Objective Assessment of Image Quality (OAIQ) focused largely on estimation or classification tasks in which the desired outcome of imaging is accurate diagnosis. This paper develops a general framework for assessing imaging quality on the basis of therapeutic outcomes rather than diagnostic performance. By analogy to Receiver Operating Characteristic (ROC) curves and their variants as used in diagnostic OAIQ, the method proposed here utilizes the Therapy Operating Characteristic or TOC curves, which are plots of the probability of tumor control vs. the probability of normal-tissue complications as the overall dose level of a radiotherapy treatment is varied. The proposed figure of merit is the area under the TOC curve, denoted AUTOC. This paper reviews an earlier exposition of the theory of TOC and AUTOC, which was specific to the assessment of image-segmentation algorithms, and extends it to other applications of imaging in external-beam radiation treatment as well as in treatment with internal radioactive sources. For each application, a methodology for computing the TOC is presented. A key difference between ROC and TOC is that the latter can be defined for a single patient rather than a population of patients. PMID:24200954

  6. Quality assessments for cancer centers in the European Union.

    PubMed

    Wind, Anke; Rajan, Abinaya; van Harten, Wim H

    2016-09-07

    Cancer centers are pressured to deliver high-quality services that can be measured and improved, which has led to an increase of assessments in many countries. A critical area of quality improvement is to improve patient outcome. An overview of existing assessments can help stakeholders (e.g., healthcare professionals, managers and policy makers) improve the quality of cancer research and care and lead to patient benefits. This paper presents key aspects of assessments undertaken by European cancer centers, such as: are assessments mandatory or voluntary? Do they focus on evaluating research, care or both? And are they international or national? A survey was sent to 33 cancer centers in 28 European Union member states. Participants were asked to score the specifics for each assessment that they listed. Based on the responses from 19 cancer centers from 18 member states, we found 109 assessments. The numbers have steadily increased from 1990's till 2015. Although, a majority of assessments are on patient-care aspects (n = 45), it is unclear how many of those include assessing patient benefits. Only few assessments cover basic research. There is an increasing trend towards mixed assessments (i.e., combining research and patient-care aspects) The need for assessments in cancer centers is increasing. To improve efforts in the quality of research and patient care and to prevent new assessments that "reinvent the wheel", it is advised to start comparative research into the assessments that are likely to bring patient benefits and improve patient outcome. Do assessments provide consistent and reliable information that create added value for all key stakeholders?

  7. Assessing Medical Tourism Services Quality Using SERVQUAL Model: A Patient’s Perspective

    PubMed Central

    QOLIPOUR, Mohammad; TORABIPOUR, Amin; FARAJI KHIAVI, Farzad; SAKI MALEHI, Amal

    2018-01-01

    Background: Continuous quality improvement of the hospital services is a basic requirement of medical tourism industry. The different dimensions of hospital services quality are assessed constantly to improve the service of medical tourism. The aim of this study was to determine the services quality of medical tourism in private and public hospitals. Methods: In this cross-sectional study, the quality of hospital services were assessed in view of 250 Iraqi tourists referred to Ahvaz private and public hospitals in 2015. Data were collected using a valid medical tourism SERVQUAL questionnaire (MTSQ). This questionnaire includes 8 main dimensions with 31 items. Finally, Mann-Whitney, Kruskal-Wallis and Wilcoxon tests were used to analyze the data. Results: The mean of age of patients was 39±2.2 yr. The mean of hospital length of stay was 3.87±1.36 days. The most patients were admitted to Orthopedics, Otorhinolaryngology, Obstetrics, and Gynecology departments, respectively. There was a negative gap in all of the dimensions of service quality in the studied hospitals (P>0.001). The highest and lowest quality gap was seen in the “exchange and travel facilities” (−2.63) and the “tangibles” (−0.68) dimension, respectively. Conclusion: There was a negative gap in all of the dimensions of service quality in the studied hospitals. Therefore, the hospital services quality is improved to attract the foreign patients. PMID:29318124

  8. 42 CFR 460.140 - Additional quality assessment activities.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Quality Assessment and Performance Improvement § 460.140 Additional quality...

  9. Water Quality Assessment using Satellite Remote Sensing

    NASA Astrophysics Data System (ADS)

    Haque, Saad Ul

    2016-07-01

    The two main global issues related to water are its declining quality and quantity. Population growth, industrialization, increase in agriculture land and urbanization are the main causes upon which the inland water bodies are confronted with the increasing water demand. The quality of surface water has also been degraded in many countries over the past few decades due to the inputs of nutrients and sediments especially in the lakes and reservoirs. Since water is essential for not only meeting the human needs but also to maintain natural ecosystem health and integrity, there are efforts worldwide to assess and restore quality of surface waters. Remote sensing techniques provide a tool for continuous water quality information in order to identify and minimize sources of pollutants that are harmful for human and aquatic life. The proposed methodology is focused on assessing quality of water at selected lakes in Pakistan (Sindh); namely, HUBDAM, KEENJHAR LAKE, HALEEJI and HADEERO. These lakes are drinking water sources for several major cities of Pakistan including Karachi. Satellite imagery of Landsat 7 (ETM+) is used to identify the variation in water quality of these lakes in terms of their optical properties. All bands of Landsat 7 (ETM+) image are analyzed to select only those that may be correlated with some water quality parameters (e.g. suspended solids, chlorophyll a). The Optimum Index Factor (OIF) developed by Chavez et al. (1982) is used for selection of the optimum combination of bands. The OIF is calculated by dividing the sum of standard deviations of any three bands with the sum of their respective correlation coefficients (absolute values). It is assumed that the band with the higher standard deviation contains the higher amount of 'information' than other bands. Therefore, OIF values are ranked and three bands with the highest OIF are selected for the visual interpretation. A color composite image is created using these three bands. The water quality

  10. [Seed quality test methods of Paeonia suffruticosa].

    PubMed

    Cao, Ya-Yue; Zhu, Zai-Biao; Guo, Qiao-Sheng; Liu, Li; Wang, Chang-Lin

    2014-11-01

    In order to optimize the testing methods for Paeonia suffruticosa seed quality, and provide basis for establishing seed testing rules and seed quality standard of P. suffruticosa. The seed quality of P. suffruticosa from different producing areas was measured based on the related seed testing regulations. The seed testing methods for quality items of P. suffruticosa was established preliminarily. The samples weight of P. suffruticosa was at least 7 000 g for purity analysis and was at least 700 g for test. The phenotypic observation and size measurement were used for authenticity testing. The 1 000-seed weight was determined by 100-seed method, and the water content was carried out by low temperature drying method (10 hours). After soaking in distilled water for 24 h, the seeds was treated with different temperature stratifications of day and night (25 degrees C/20 degrees C, day/night) in the dark for 60 d. After soaking in the liquor of GA3 300 mg x L(-1) for 24 h, the P. suffruticos seeds were cultured in wet sand at 15 degrees C for 12-60 days for germination testing. Seed viability was tested by TlC method.

  11. Higher Education Quality Assessment in China: An Impact Study

    ERIC Educational Resources Information Center

    Liu, Shuiyun

    2015-01-01

    This research analyses an external higher education quality assessment scheme in China, namely, the Quality Assessment of Undergraduate Education (QAUE) scheme. Case studies were conducted in three Chinese universities with different statuses. Analysis shows that the evaluated institutions responded to the external requirements of the QAUE…

  12. Air quality assessment for land disposal of industrial wastes

    NASA Astrophysics Data System (ADS)

    Shen, Thomas T.

    1982-07-01

    Air pollution from hazardous waste landfills and lagoons is largely unknown. Routine monitoring of toxic air contaminants associated with hazardous waste facilities is difficult and very costly. The method presented in this paper would be useful for air quality assessment in the absence of monitoring data. It may be used as a screening process to examine the question of whether or not volatilization is considered to be significant for a given contaminant and also to evaluate permit applications for new hazardous waste facilities concerning waste volatilization problems.

  13. Assessing Personal Qualities in Medical School Admissions.

    ERIC Educational Resources Information Center

    Albanese, Mark A.; Snow, Mikel H.; Skochelak, Susan E.; Huggett, Kathryn N.; Farrell, Philip M.

    2003-01-01

    Analyzes the challenges to using academic measures (MCAT scores and GPAs) as thresholds for medical school admissions and, for applicants exceeding the threshold, using personal qualities for admission decisions; reviews the literature on using the medical school interview and other admission data to assess personal qualities of applicants;…

  14. Portable Imagery Quality Assessment Test Field for Uav Sensors

    NASA Astrophysics Data System (ADS)

    Dąbrowski, R.; Jenerowicz, A.

    2015-08-01

    Nowadays the imagery data acquired from UAV sensors are the main source of all data used in various remote sensing applications, photogrammetry projects and in imagery intelligence (IMINT) as well as in other tasks as decision support. Therefore quality assessment of such imagery is an important task. The research team from Military University of Technology, Faculty of Civil Engineering and Geodesy, Geodesy Institute, Department of Remote Sensing and Photogrammetry has designed and prepared special test field- The Portable Imagery Quality Assessment Test Field (PIQuAT) that provides quality assessment in field conditions of images obtained with sensors mounted on UAVs. The PIQuAT consists of 6 individual segments, when combined allow for determine radiometric, spectral and spatial resolution of images acquired from UAVs. All segments of the PIQuAT can be used together in various configurations or independently. All elements of The Portable Imagery Quality Assessment Test Field were tested in laboratory conditions in terms of their radiometry and spectral reflectance characteristics.

  15. Analysis of quality raw data of second generation sequencers with Quality Assessment Software.

    PubMed

    Ramos, Rommel Tj; Carneiro, Adriana R; Baumbach, Jan; Azevedo, Vasco; Schneider, Maria Pc; Silva, Artur

    2011-04-18

    Second generation technologies have advantages over Sanger; however, they have resulted in new challenges for the genome construction process, especially because of the small size of the reads, despite the high degree of coverage. Independent of the program chosen for the construction process, DNA sequences are superimposed, based on identity, to extend the reads, generating contigs; mismatches indicate a lack of homology and are not included. This process improves our confidence in the sequences that are generated. We developed Quality Assessment Software, with which one can review graphs showing the distribution of quality values from the sequencing reads. This software allow us to adopt more stringent quality standards for sequence data, based on quality-graph analysis and estimated coverage after applying the quality filter, providing acceptable sequence coverage for genome construction from short reads. Quality filtering is a fundamental step in the process of constructing genomes, as it reduces the frequency of incorrect alignments that are caused by measuring errors, which can occur during the construction process due to the size of the reads, provoking misassemblies. Application of quality filters to sequence data, using the software Quality Assessment, along with graphing analyses, provided greater precision in the definition of cutoff parameters, which increased the accuracy of genome construction.

  16. Development and Validation of a Consumer Quality Assessment Instrument for Dentistry.

    ERIC Educational Resources Information Center

    Johnson, Jeffrey D.; And Others

    1990-01-01

    This paper reviews the literature on consumer involvement in dental quality assessment, argues for inclusion of this information in quality assessment measures, outlines a conceptual model for measuring dental consumer quality assessment, and presents data relating to the development and validation of an instrument based on the conceptual model.…

  17. Assessing the quality of healthcare provided to children.

    PubMed

    Mangione-Smith, R; McGlynn, E A

    1998-10-01

    To present a conceptual framework for evaluating quality of care for children and adolescents, summarize the key issues related to developing measures to assess pediatric quality of care, examine some existing measures, and present evidence about their current level of performance. Assessing the quality of care for children poses many challenges not encountered when making these measurements in the adult population. Children and adolescents (from this point forward referred to collectively as children unless differentiation is necessary) differ from adults in two clinically important ways (Jameson and Wehr 1993): (1) their normal developmental trajectory is characterized by change, and (2) they have differential morbidity. These factors contribute to the limitations encountered when developing measures to assess the quality of care for children. The movement of a child through the various stages of development makes it difficult to establish what constitutes a "normal" outcome and by extension what constitutes a poor outcome. Additionally, salient developmental outcomes that result from poor quality of care may not be observed for several years. This implies that poor outcomes may be observed when the child is receiving care from a delivery system other than the one that provided the low-quality care. Attributing the suboptimal outcome to the new delivery system would be inappropriate. Differential morbidity refers to the fact that the type, prevalence, and severity of illness experienced by children is measurably different from that observed in adults. Most children experience numerous self-limited illness of mild severity. A minority of children suffer from markedly more severe diseases. Thus, condition-specific measures in children are problematic to implement for routine assessments because of the extremely low incidence and prevalence of most severe pediatric diseases (Halfon 1996). However, children with these conditions are potentially the segment of the

  18. Improving the Quality of School Facilities through Building Performance Assessment: Educational Reform and School Building Quality in Sao Paulo, Brazil

    ERIC Educational Resources Information Center

    Ornstein, Sheila Walbe; Moreira, Nanci Saraiva; Ono, Rosaria; Limongi Franca, Ana J. G.; Nogueira, Roselene A. M. F.

    2009-01-01

    Purpose: The paper describes the purpose of and strategies for conducting post-occupancy evaluations (POEs) as a method for assessing school building performance. Set within the larger context of global efforts to develop and apply common indicators of school building quality, the authors describe research conducted within the newest generation of…

  19. Chapter 4: Assessing the Air Pollution, Greenhouse Gas, Air Quality, and Health Benefits of Clean Energy Initiatives

    EPA Pesticide Factsheets

    Chapter 4 of Assessing the Multiple Benefits of Clean Energy helps state states understand the methods, models, opportunities, and issues associated with assessing the GHG, air pollution, air quality, and human health benefits of clean energy options.

  20. Rapid quality assessment of Radix Aconiti Preparata using direct analysis in real time mass spectrometry.

    PubMed

    Zhu, Hongbin; Wang, Chunyan; Qi, Yao; Song, Fengrui; Liu, Zhiqiang; Liu, Shuying

    2012-11-08

    This study presents a novel and rapid method to identify chemical markers for the quality control of Radix Aconiti Preparata, a world widely used traditional herbal medicine. In the method, the samples with a fast extraction procedure were analyzed using direct analysis in real time mass spectrometry (DART MS) combined with multivariate data analysis. At present, the quality assessment approach of Radix Aconiti Preparata was based on the two processing methods recorded in Chinese Pharmacopoeia for the purpose of reducing the toxicity of Radix Aconiti and ensuring its clinical therapeutic efficacy. In order to ensure the safety and effectivity in clinical use, the processing degree of Radix Aconiti should be well controlled and assessed. In the paper, hierarchical cluster analysis and principal component analysis were performed to evaluate the DART MS data of Radix Aconiti Preparata samples in different processing times. The results showed that the well processed Radix Aconiti Preparata, unqualified processed and the raw Radix Aconiti could be clustered reasonably corresponding to their constituents. The loading plot shows that the main chemical markers having the most influence on the discrimination amongst the qualified and unqualified samples were mainly some monoester diterpenoid aconitines and diester diterpenoid aconitines, i.e. benzoylmesaconine, hypaconitine, mesaconitine, neoline, benzoylhypaconine, benzoylaconine, fuziline, aconitine and 10-OH-mesaconitine. The established DART MS approach in combination with multivariate data analysis provides a very flexible and reliable method for quality assessment of toxic herbal medicine. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. pcr: an R package for quality assessment, analysis and testing of qPCR data

    PubMed Central

    Ahmed, Mahmoud

    2018-01-01

    Background Real-time quantitative PCR (qPCR) is a broadly used technique in the biomedical research. Currently, few different analysis models are used to determine the quality of data and to quantify the mRNA level across the experimental conditions. Methods We developed an R package to implement methods for quality assessment, analysis and testing qPCR data for statistical significance. Double Delta CT and standard curve models were implemented to quantify the relative expression of target genes from CT in standard qPCR control-group experiments. In addition, calculation of amplification efficiency and curves from serial dilution qPCR experiments are used to assess the quality of the data. Finally, two-group testing and linear models were used to test for significance of the difference in expression control groups and conditions of interest. Results Using two datasets from qPCR experiments, we applied different quality assessment, analysis and statistical testing in the pcr package and compared the results to the original published articles. The final relative expression values from the different models, as well as the intermediary outputs, were checked against the expected results in the original papers and were found to be accurate and reliable. Conclusion The pcr package provides an intuitive and unified interface for its main functions to allow biologist to perform all necessary steps of qPCR analysis and produce graphs in a uniform way. PMID:29576953

  2. The compressed average image intensity metric for stereoscopic video quality assessment

    NASA Astrophysics Data System (ADS)

    Wilczewski, Grzegorz

    2016-09-01

    The following article depicts insights towards design, creation and testing of a genuine metric designed for a 3DTV video quality evaluation. The Compressed Average Image Intensity (CAII) mechanism is based upon stereoscopic video content analysis, setting its core feature and functionality to serve as a versatile tool for an effective 3DTV service quality assessment. Being an objective type of quality metric it may be utilized as a reliable source of information about the actual performance of a given 3DTV system, under strict providers evaluation. Concerning testing and the overall performance analysis of the CAII metric, the following paper presents comprehensive study of results gathered across several testing routines among selected set of samples of stereoscopic video content. As a result, the designed method for stereoscopic video quality evaluation is investigated across the range of synthetic visual impairments injected into the original video stream.

  3. Framework and tools for agricultural landscape assessment relating to water quality protection.

    PubMed

    Gascuel-Odoux, Chantal; Massa, Florence; Durand, Patrick; Merot, Philippe; Troccaz, Olivier; Baudry, Jacques; Thenail, Claudine

    2009-05-01

    While many scientific studies show the influence of agricultural landscape patterns on water cycle and water quality, only a few of these have proposed scientifically based and operational methods to improve water management. Territ'eau is a framework developed to adapt agricultural landscapes to water quality protection, using components such as farmers' fields, seminatural areas, and human infrastructures, which can act as sources, sinks, or buffers on water quality. This framework allows us to delimit active areas contributing to water quality, defined by the following three characteristics: (i) the dominant hydrological processes and their flow pathways, (ii) the characteristics of each considered pollutant, and (iii) the main landscape features. These areas are delineated by analyzing the flow connectivity from the stream to the croplands, by assessing the buffer functions of seminatural areas according to their flow pathways. Hence, this framework allows us to identify functional seminatural areas in terms of water quality and assess their limits and functions; it helps in proposing different approaches for changing agricultural landscape, acting on agricultural practices or systems, and/or conserving or rebuilding seminatural areas in controversial landscapes. Finally, it allows us to objectivize the functions of the landscape components, for adapting these components to new environmental constraints.

  4. Method and reporting quality in health professions education research: a systematic review.

    PubMed

    Cook, David A; Levinson, Anthony J; Garside, Sarah

    2011-03-01

    Studies evaluating reporting quality in health professions education (HPE) research have demonstrated deficiencies, but none have used comprehensive reporting standards. Additionally, the relationship between study methods and effect size (ES) in HPE research is unknown. This review aimed to evaluate, in a sample of experimental studies of Internet-based instruction, the quality of reporting, the relationship between reporting and methodological quality, and associations between ES and study methods. We conducted a systematic search of databases including MEDLINE, Scopus, CINAHL, EMBASE and ERIC, for articles published during 1990-2008. Studies (in any language) quantifying the effect of Internet-based instruction in HPE compared with no intervention or other instruction were included. Working independently and in duplicate, we coded reporting quality using the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement, and coded study methods using a modified Newcastle-Ottawa Scale (m-NOS), the Medical Education Research Study Quality Instrument (MERSQI), and the Best Evidence in Medical Education (BEME) global scale. For reporting quality, articles scored a mean±standard deviation (SD) of 51±25% of STROBE elements for the Introduction, 58±20% for the Methods, 50±18% for the Results and 41±26% for the Discussion sections. We found positive associations (all p<0.0001) between reporting quality and MERSQI (ρ=0.64), m-NOS (ρ=0.57) and BEME (ρ=0.58) scores. We explored associations between study methods and knowledge ES by subtracting each study's ES from the pooled ES for studies using that method and comparing these differences between subgroups. Effect sizes in single-group pretest/post-test studies differed from the pooled estimate more than ESs in two-group studies (p=0.013). No difference was found between other study methods (yes/no: representative sample, comparison group from same community, randomised, allocation

  5. [Validation of a questionnaire to assess the quality of health information in Argentinian newspapers].

    PubMed

    Biondo, Emiliano; Khoury, Marina Claudia

    2005-09-01

    The daily press is an important source of health information and may influence health care utilization. However, medical reports published in newspapers from developed countries have shown a poor quality. The reliability of the questionnaire Index of Scientific Quality was evaluated by using it to measure the scientific quality of health information published by Argentinian newspapers between 2000 and 2002. It assessed the readability of the texts in grade levels and explored the relationship between quality and other factors. The Spanish adaptation of the instrument consisted in translation, back-traslation and pilot study. The reliability was assessed by applying the instrument to newspaper articles with more than 300 words that discussed therapy, diagnosis, prevention, lifestyle effects, and hazardous exposure. Two physicians independently graded 129 articles. Inter-observer and intra-observer concordance was quantified for each item with the intra-class correlation coefficient (CI95%). To measure scientific quality, a randomized sample of 210 articles was assessed. Each received a mark that ranged from 0 to 100. Readability was determined by the FRY graph method. The relationship between quality and other variables was explored with multiple linear regression analysis. The inter-rater concordance varied between 0.48 (0.34-0.61) and 0.67 (0.56-0.75). Intra-rater concordance varied from 0.51 (0.37-0.63) to 0.95 (0.93-0.96). The internal consistency (Cronbach's alpha) was 0.88. The quality-of-health-information was rated at 25 points (16.7, 33.3) [median (intercuartil range)]. The reading level was assessed to be at the 10.4 grade (10.2-10.6) [mean (CI 95%)]. Quality of the health information was greatly deficient; however, no specific factors were related with quality. Readability was probably a key barrier for access to the health information.

  6. DOGMA: domain-based transcriptome and proteome quality assessment.

    PubMed

    Dohmen, Elias; Kremer, Lukas P M; Bornberg-Bauer, Erich; Kemena, Carsten

    2016-09-01

    Genome studies have become cheaper and easier than ever before, due to the decreased costs of high-throughput sequencing and the free availability of analysis software. However, the quality of genome or transcriptome assemblies can vary a lot. Therefore, quality assessment of assemblies and annotations are crucial aspects of genome analysis pipelines. We developed DOGMA, a program for fast and easy quality assessment of transcriptome and proteome data based on conserved protein domains. DOGMA measures the completeness of a given transcriptome or proteome and provides information about domain content for further analysis. DOGMA provides a very fast way to do quality assessment within seconds. DOGMA is implemented in Python and published under GNU GPL v.3 license. The source code is available on https://ebbgit.uni-muenster.de/domainWorld/DOGMA/ CONTACTS: e.dohmen@wwu.de or c.kemena@wwu.de Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  7. External quality assessment for EGFR mutations in Italy: improvements in performances over the time.

    PubMed

    Normanno, Nicola; Fenizia, Francesca; Castiglione, Francesca; Barberis, Massimo; Taddei, Gian Luigi; Truini, Mauro; De Rosa, Gaetano; Pinto, Carmine; Marchetti, Antonio

    2017-01-01

    External quality assessment (EQA) schemes are essential procedures to assess the quality level of laboratories performing molecular testing of the epidermal growth factor receptor ( EGFR ) gene in non-small cell lung cancer. The Italian Association of Medical Oncology (AIOM) and the Italian Society of Pathology (SIAPEC-IAP) organise EGFR EQA programmes to ensure that the Italian laboratories achieve the quality standard levels required. Comparing the 2011, 2013 and 2015 EGFR EQA schemes, it was possible to observe improvements in the methodologies used and the outcomes. The use of direct sequencing was reduced from 78.7% in 2011 to only 14.1% in 2015, whereas the use of pyrosequencing and real-time PCR increased. The number of rounds in which centres using direct sequencing failed was significantly higher than the number of rounds that failed using other methods, both when analysing each single scheme and when combining the three EQAs together. In 2011 and 2013, about 29% of the participants failed the first phase of the programmes, compared with the 13% of centres failing in 2015, suggesting that the switch to more sensitive and robust methods could allow to increase the percentage of good performers. Although the molecular analyses are performed with good quality in Italy, the continuous education carried out by AIOM and SIAPEC-IAP remains a fundamental tool to maintain this quality level.

  8. External quality assessment for EGFR mutations in Italy: improvements in performances over the time

    PubMed Central

    Normanno, Nicola; Fenizia, Francesca; Castiglione, Francesca; Barberis, Massimo; Taddei, Gian Luigi; Truini, Mauro; De Rosa, Gaetano; Pinto, Carmine; Marchetti, Antonio

    2017-01-01

    External quality assessment (EQA) schemes are essential procedures to assess the quality level of laboratories performing molecular testing of the epidermal growth factor receptor (EGFR) gene in non-small cell lung cancer. The Italian Association of Medical Oncology (AIOM) and the Italian Society of Pathology (SIAPEC-IAP) organise EGFR EQA programmes to ensure that the Italian laboratories achieve the quality standard levels required. Comparing the 2011, 2013 and 2015 EGFR EQA schemes, it was possible to observe improvements in the methodologies used and the outcomes. The use of direct sequencing was reduced from 78.7% in 2011 to only 14.1% in 2015, whereas the use of pyrosequencing and real-time PCR increased. The number of rounds in which centres using direct sequencing failed was significantly higher than the number of rounds that failed using other methods, both when analysing each single scheme and when combining the three EQAs together. In 2011 and 2013, about 29% of the participants failed the first phase of the programmes, compared with the 13% of centres failing in 2015, suggesting that the switch to more sensitive and robust methods could allow to increase the percentage of good performers. Although the molecular analyses are performed with good quality in Italy, the continuous education carried out by AIOM and SIAPEC-IAP remains a fundamental tool to maintain this quality level. PMID:29181190

  9. High-performance thin layer chromatography to assess pharmaceutical product quality.

    PubMed

    Kaale, Eliangiringa; Manyanga, Vicky; Makori, Narsis; Jenkins, David; Michael Hope, Samuel; Layloff, Thomas

    2014-06-01

    To assess the sustainability, robustness and economic advantages of high-performance thin layer chromatography (HPTLC) for quality control of pharmaceutical products. We compared three laboratories where three lots of cotrimoxazole tablets were assessed using different techniques for quantifying the active ingredient. The average assay relative standard deviation for the three lots was 1.2 with a range of 0.65-2.0. High-performance thin layer chromatography assessments are yielding valid results suitable for assessing product quality. The local pharmaceutical manufacturer had evolved the capacity to produce very high quality products. © 2014 John Wiley & Sons Ltd.

  10. Are Patent Medicine Vendors Effective Agents in Malaria Control? Using Lot Quality Assurance Sampling to Assess Quality of Practice in Jigawa, Nigeria

    PubMed Central

    Berendes, Sima; Adeyemi, Olusegun; Oladele, Edward Adekola; Oresanya, Olusola Bukola; Okoh, Festus; Valadez, Joseph J.

    2012-01-01

    Background Patent medicine vendors (PMV) provide antimalarial treatment and care throughout Sub-Saharan Africa, and can play an important role in the fight against malaria. Their close-to-client infrastructure could enable lifesaving artemisinin-based combination therapy (ACT) to reach patients in time. However, systematic assessments of drug sellers’ performance quality are crucial if their role is to be managed within the health system. Lot quality assurance sampling (LQAS) could be an efficient method to monitor and evaluate PMV practice, but has so far never been used for this purpose. Methods In support of the Nigeria Malaria Booster Program we assessed PMV practices in three Senatorial Districts (SDs) of Jigawa, Nigeria. A two-stage LQAS assessed whether at least 80% of PMV stores in SDs used national treatment guidelines. Acceptable sampling errors were set in consultation with government officials (alpha and beta <0.10). The hypergeometric formula determined sample sizes and cut-off values for SDs. A structured assessment tool identified high and low performing SDs for quality of care indicators. Findings Drug vendors performed poorly in all SDs of Jigawa for all indicators. For example, all SDs failed for stocking and selling first-line antimalarials. PMV sold no longer recommended antimalarials, such as Chloroquine, Sulfadoxine-Pyrimethamine and oral Artesunate monotherapy. Most PMV were ignorant of and lacked training about new treatment guidelines that had endorsed ACTs as first-line treatment for uncomplicated malaria. Conclusion There is urgent need to regularly monitor and improve the availability and quality of malaria treatment provided by medicine sellers in Nigeria; the irrational use of antimalarials in the ACT era revealed in this study bears a high risk of economic loss, death and development of drug resistance. LQAS has been shown to be a suitable method for monitoring malaria-related indicators among PMV, and should be applied in Nigeria

  11. Indoor Air Quality Building Education and Assessment Model

    EPA Pesticide Factsheets

    The Indoor Air Quality Building Education and Assessment Model (I-BEAM), released in 2002, is a guidance tool designed for use by building professionals and others interested in indoor air quality in commercial buildings.

  12. The quality of websites addressing fibromyalgia: an assessment of quality and readability using standardised tools

    PubMed Central

    MacDermid, Joy C; Wilkins, Seanne; Gibson, Jane; Shaw, Lynn

    2011-01-01

    Background Patients living with fibromyalgia strongly prefer to access health information on the web. However, the majority of subjects in previous studies strongly expressed their concerns about the quality of online information resources. Objectives The purpose of this study was to evaluate existing online fibromyalgia information resources for content, quality and readability by using standardised quality and readability tools. Methods The first 25 websites were identified using Google and the search keyword ‘fibromyalgia’. Pairs of raters independently evaluated website quality using two structured tools (DISCERN and a quality checklist). Readability was assessed using the Flesch Reading Ease score maps. Results Ranking of the websites' quality varied by the tool used, although there was general agreement about the top three websites (Fibromyalgia Information, Fibromyalgia Information Foundation and National Institute of Arthritis and Musculoskeletal and Skin Diseases). Content analysis indicated that 72% of websites provided information on treatment options, 68% on symptoms, 60% on diagnosis and 40% on coping and resources. DISCERN ratings classified 32% websites as ‘very good’, 32% as ‘good and 36% as ‘marginal’. The mean overall DISCERN score was 36.88 (good). Only 16% of websites met the recommended literacy level grade of 6–8 (range 7–15). Conclusion Higher quality websites tended to be less readable. Online fibromyalgia information resources do not provide comprehensive information about fibromyalgia, and have low quality and poor readability. While information is very important for those living with fibromyalgia, current resources are unlikely to provide necessary or accurate information, and may not be usable for most people. PMID:22021777

  13. The quality of websites addressing fibromyalgia: an assessment of quality and readability using standardised tools.

    PubMed

    Daraz, Lubna; Macdermid, Joy C; Wilkins, Seanne; Gibson, Jane; Shaw, Lynn

    2011-07-31

    Background Patients living with fibromyalgia strongly prefer to access health information on the web. However, the majority of subjects in previous studies strongly expressed their concerns about the quality of online information resources. Objectives The purpose of this study was to evaluate existing online fibromyalgia information resources for content, quality and readability by using standardised quality and readability tools. Methods The first 25 websites were identified using Google and the search keyword 'fibromyalgia'. Pairs of raters independently evaluated website quality using two structured tools (DISCERN and a quality checklist). Readability was assessed using the Flesch Reading Ease score maps. Results Ranking of the websites' quality varied by the tool used, although there was general agreement about the top three websites (Fibromyalgia Information, Fibromyalgia Information Foundation and National Institute of Arthritis and Musculoskeletal and Skin Diseases). Content analysis indicated that 72% of websites provided information on treatment options, 68% on symptoms, 60% on diagnosis and 40% on coping and resources. DISCERN ratings classified 32% websites as 'very good', 32% as 'good and 36% as 'marginal'. The mean overall DISCERN score was 36.88 (good). Only 16% of websites met the recommended literacy level grade of 6-8 (range 7-15). Conclusion Higher quality websites tended to be less readable. Online fibromyalgia information resources do not provide comprehensive information about fibromyalgia, and have low quality and poor readability. While information is very important for those living with fibromyalgia, current resources are unlikely to provide necessary or accurate information, and may not be usable for most people.

  14. A ranking index for quality assessment of forensic DNA profiles forensic DNA profiles

    PubMed Central

    2010-01-01

    Background Assessment of DNA profile quality is vital in forensic DNA analysis, both in order to determine the evidentiary value of DNA results and to compare the performance of different DNA analysis protocols. Generally the quality assessment is performed through manual examination of the DNA profiles based on empirical knowledge, or by comparing the intensities (allelic peak heights) of the capillary electrophoresis electropherograms. Results We recently developed a ranking index for unbiased and quantitative quality assessment of forensic DNA profiles, the forensic DNA profile index (FI) (Hedman et al. Improved forensic DNA analysis through the use of alternative DNA polymerases and statistical modeling of DNA profiles, Biotechniques 47 (2009) 951-958). FI uses electropherogram data to combine the intensities of the allelic peaks with the balances within and between loci, using Principal Components Analysis. Here we present the construction of FI. We explain the mathematical and statistical methodologies used and present details about the applied data reduction method. Thereby we show how to adapt the ranking index for any Short Tandem Repeat-based forensic DNA typing system through validation against a manual grading scale and calibration against a specific set of DNA profiles. Conclusions The developed tool provides unbiased quality assessment of forensic DNA profiles. It can be applied for any DNA profiling system based on Short Tandem Repeat markers. Apart from crime related DNA analysis, FI can therefore be used as a quality tool in paternal or familial testing as well as in disaster victim identification. PMID:21062433

  15. Diagnostic methods for assessing maxillary skeletal and dental transverse deficiencies: A systematic review

    PubMed Central

    Sawchuk, Dena; Currie, Kris; Vich, Manuel Lagravere; Palomo, Juan Martin

    2016-01-01

    Objective To evaluate the accuracy and reliability of the diagnostic tools available for assessing maxillary transverse deficiencies. Methods An electronic search of three databases was performed from their date of establishment to April 2015, with manual searching of reference lists of relevant articles. Articles were considered for inclusion if they reported the accuracy or reliability of a diagnostic method or evaluation technique for maxillary transverse dimensions in mixed or permanent dentitions. Risk of bias was assessed in the included articles, using the Quality Assessment of Diagnostic Accuracy Studies tool-2. Results Nine articles were selected. The studies were heterogeneous, with moderate to low methodological quality, and all had a high risk of bias. Four suggested that the use of arch width prediction indices with dental cast measurements is unreliable for use in diagnosis. Frontal cephalograms derived from cone-beam computed tomography (CBCT) images were reportedly more reliable for assessing intermaxillary transverse discrepancies than posteroanterior cephalograms. Two studies proposed new three-dimensional transverse analyses with CBCT images that were reportedly reliable, but have not been validated for clinical sensitivity or specificity. No studies reported sensitivity, specificity, positive or negative predictive values or likelihood ratios, or ROC curves of the methods for the diagnosis of transverse deficiencies. Conclusions Current evidence does not enable solid conclusions to be drawn, owing to a lack of reliable high quality diagnostic studies evaluating maxillary transverse deficiencies. CBCT images are reportedly more reliable for diagnosis, but further validation is required to confirm CBCT's accuracy and diagnostic superiority. PMID:27668196

  16. Ultra-HPLC method for quality and adulterant assessment of steviol glycosides sweeteners - Stevia rebaudiana and stevia products.

    PubMed

    Wang, Yan-Hong; Avula, Bharathi; Tang, Wenzhao; Wang, Mei; Elsohly, Mahmoud A; Khan, Ikhlas A

    2015-01-01

    Stevia products are advertised as a zero-calorie sweetener. Glucose should not be an intrinsic component of this product, but it has been identified from some of stevia products in a preliminary study. An UHPLC-UV method was developed for the quantitative determination of glucose from stevia products. After stevia products reacted with 1-phenyl-3-methyl-5-pyrazolone (PMP), PMP derivatives were analysed and glucose was found in seven out of 35 products in the range 0.3-91.5% (w/w). Two products, SPR-12 and SPR-27, showed remarkable amounts of glucose at 61.6% and 91.5%, respectively. In addition, an UHPLC-UV-evaporative light-scattering detector (ELSD) method was developed for the quantitative determination of rebaudioside A, stevioside, rebaudioside D, dulcoside A and steviolbioside from Stevia rebaudiana and related products. In a 12 min run, five steviol glycosides were baseline-separated. ELSD and ultraviolet (UV) detections showed comparable results. The LC methods were validated for linearity, repeatability, accuracy, limits of detection (LOD) and limits of quantification (LOQ). For steviol glycosides, the LODs and LOQs were found to be less than 10 and 30 μg ml(-1), respectively. The RSD for intra- and inter-day analyses was less than 2.5%, and the recovery was 90-94%. For PMP derivative of glucose, the LOD and LOQ were 0.01 and 0.05 μg ml(-1), respectively. Repeatability (RSD) was less than 2.6%; recovery was 98.6-101.7%. The methods are useful for the identification, quality assurance, and adulterant assessment of S. rebaudiana and steviol glycosides sweeteners (stevia products).

  17. Virginia Star Quality Initiative: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Virginia's Star Quality Initiative prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators…

  18. Mississippi Quality Step System: QRS Profile. The Child Care Quality Rating System (QRS)Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Mississippi's Quality Step System prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Application…

  19. Methodological Quality Assessment of Meta-analyses in Endodontics.

    PubMed

    Kattan, Sereen; Lee, Su-Min; Kohli, Meetu R; Setzer, Frank C; Karabucak, Bekir

    2018-01-01

    The objectives of this review were to assess the methodological quality of published meta-analyses related to endodontics using the assessment of multiple systematic reviews (AMSTAR) tool and to provide a follow-up to previously published reviews. Three electronic databases were searched for eligible studies according to the inclusion and exclusion criteria: Embase via Ovid, The Cochrane Library, and Scopus. The electronic search was amended by a hand search of 6 dental journals (International Endodontic Journal; Journal of Endodontics; Australian Endodontic Journal; Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology; Endodontics and Dental Traumatology; and Journal of Dental Research). The searches were conducted to include articles published after July 2009, and the deadline for inclusion of the meta-analyses was November 30, 2016. The AMSTAR assessment tool was used to evaluate the methodological quality of all included studies. A total of 36 reports of meta-analyses were included. The overall quality of the meta-analyses reports was found to be medium, with an estimated mean overall AMSTAR score of 7.25 (95% confidence interval, 6.59-7.90). The most poorly assessed areas were providing an a priori design, the assessment of the status of publication, and publication bias. In recent publications in the field of endodontics, the overall quality of the reported meta-analyses is medium according to AMSTAR. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  20. Assessment of Methodological Quality of Economic Evaluations in Belgian Drug Reimbursement Applications

    PubMed Central

    Simoens, Steven

    2013-01-01

    Objectives This paper aims to assess the methodological quality of economic evaluations included in Belgian reimbursement applications for Class 1 drugs. Materials and Methods For 19 reimbursement applications submitted during 2011 and Spring 2012, a descriptive analysis assessed the methodological quality of the economic evaluation, evaluated the assessment of that economic evaluation by the Drug Reimbursement Committee and the response to that assessment by the company. Compliance with methodological guidelines issued by the Belgian Healthcare Knowledge Centre was assessed using a detailed checklist of 23 methodological items. The rate of compliance was calculated based on the number of economic evaluations for which the item was applicable. Results Economic evaluations tended to comply with guidelines regarding perspective, target population, subgroup analyses, comparator, use of comparative clinical data and final outcome measures, calculation of costs, incremental analysis, discounting and time horizon. However, more attention needs to be paid to the description of limitations of indirect comparisons, the choice of an appropriate analytic technique, the expression of unit costs in values for the current year, the estimation and valuation of outcomes, the presentation of results of sensitivity analyses, and testing the face validity of model inputs and outputs. Also, a large variation was observed in the scope and depth of the quality assessment by the Drug Reimbursement Committee. Conclusions Although general guidelines exist, pharmaceutical companies and the Drug Reimbursement Committee would benefit from the existence of a more detailed checklist of methodological items that need to be reported in an economic evaluation. PMID:24386474

  1. Water quality assessment of Australian ports using water quality evaluation indices

    PubMed Central

    Jahan, Sayka

    2017-01-01

    Australian ports serve diverse and extensive activities, such as shipping, tourism and fisheries, which may all impact the quality of port water. In this work water quality monitoring at different ports using a range of water quality evaluation indices was applied to assess the port water quality. Seawater samples at 30 stations in the year 2016–2017 from six ports in NSW, Australia, namely Port Jackson, Botany, Kembla, Newcastle, Yamba and Eden, were investigated to determine the physicochemical and biological variables that affect the port water quality. The large datasets obtained were designed to determine the Water Quality Index, Heavy metal Evaluation Index, Contamination Index and newly developed Environmental Water Quality Index. The study revealed medium water quality index and high and medium heavy metal evaluation index at three of the study ports and high contamination index in almost all study ports. Low level dissolved oxygen and higher level of total dissolved solids, turbidity, fecal coliforms, copper, iron, lead, zinc, manganese, cadmium and cobalt are mainly responsible for the poor water qualities of the port areas. Good water quality at the background samples indicated that various port activities are the likely cause for poor water quality inside the port area. PMID:29244876

  2. Quality assessment for VMAT prostate radiotherapy planning based on data envelopment analysis

    NASA Astrophysics Data System (ADS)

    Lin, Kuan-Min; Simpson, John; Sasso, Giuseppe; Raith, Andrea; Ehrgott, Matthias

    2013-08-01

    The majority of commercial radiotherapy treatment planning systems requires planners to iteratively adjust the plan parameters in order to find a satisfactory plan. This iterative trial-and-error nature of radiotherapy treatment planning results in an inefficient planning process and in order to reduce such inefficiency, plans can be accepted without achieving the best attainable quality. We propose a quality assessment method based on data envelopment analysis (DEA) to address this inefficiency. This method compares a plan of interest to a set of past delivered plans and searches for evidence of potential further improvement. With the assistance of DEA, planners will be able to make informed decisions on whether further planning is required and ensure that a plan is only accepted when the plan quality is close to the best attainable one. We apply the DEA method to 37 prostate plans using two assessment parameters: rectal generalized equivalent uniform dose (gEUD) as the input and D95 (the minimum dose that is received by 95% volume of a structure) of the planning target volume (PTV) as the output. The percentage volume of rectum overlapping PTV is used to account for anatomical variations between patients and is included in the model as a non-discretionary output variable. Five plans that are considered of lesser quality by DEA are re-optimized with the goal to further improve rectal sparing. After re-optimization, all five plans improve in rectal gEUD without clinically considerable deterioration of the PTV D95 value. For the five re-optimized plans, the rectal gEUD is reduced by an average of 1.84 Gray (Gy) with only an average reduction of 0.07 Gy in PTV D95. The results demonstrate that DEA can correctly identify plans with potential improvements in terms of the chosen input and outputs.

  3. Chip Design Process Optimization Based on Design Quality Assessment

    NASA Astrophysics Data System (ADS)

    Häusler, Stefan; Blaschke, Jana; Sebeke, Christian; Rosenstiel, Wolfgang; Hahn, Axel

    2010-06-01

    Nowadays, the managing of product development projects is increasingly challenging. Especially the IC design of ASICs with both analog and digital components (mixed-signal design) is becoming more and more complex, while the time-to-market window narrows at the same time. Still, high quality standards must be fulfilled. Projects and their status are becoming less transparent due to this complexity. This makes the planning and execution of projects rather difficult. Therefore, there is a need for efficient project control. A main challenge is the objective evaluation of the current development status. Are all requirements successfully verified? Are all intermediate goals achieved? Companies often develop special solutions that are not reusable in other projects. This makes the quality measurement process itself less efficient and produces too much overhead. The method proposed in this paper is a contribution to solve these issues. It is applied at a German design house for analog mixed-signal IC design. This paper presents the results of a case study and introduces an optimized project scheduling on the basis of quality assessment results.

  4. EAPhy: A Flexible Tool for High-throughput Quality Filtering of Exon-alignments and Data Processing for Phylogenetic Methods.

    PubMed

    Blom, Mozes P K

    2015-08-05

    Recently developed molecular methods enable geneticists to target and sequence thousands of orthologous loci and infer evolutionary relationships across the tree of life. Large numbers of genetic markers benefit species tree inference but visual inspection of alignment quality, as traditionally conducted, is challenging with thousands of loci. Furthermore, due to the impracticality of repeated visual inspection with alternative filtering criteria, the potential consequences of using datasets with different degrees of missing data remain nominally explored in most empirical phylogenomic studies. In this short communication, I describe a flexible high-throughput pipeline designed to assess alignment quality and filter exonic sequence data for subsequent inference. The stringency criteria for alignment quality and missing data can be adapted based on the expected level of sequence divergence. Each alignment is automatically evaluated based on the stringency criteria specified, significantly reducing the number of alignments that require visual inspection. By developing a rapid method for alignment filtering and quality assessment, the consistency of phylogenetic estimation based on exonic sequence alignments can be further explored across distinct inference methods, while accounting for different degrees of missing data.

  5. Palm Beach Quality Counts: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Palm Beach's Quality Counts prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for…

  6. Maine Quality for ME: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Maine's Quality for ME prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for Family…

  7. Missouri Quality Rating System: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Missouri's Quality Rating System prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for…

  8. Miami-Dade Quality Counts: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Miami-Dade's Quality Counts prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for…

  9. Indiana Paths to Quality: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Indiana's Paths to Quality prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for…

  10. Whole blood treated with riboflavin and ultraviolet light: quality assessment of all blood components produced by the buffy coat method.

    PubMed

    Schubert, Peter; Culibrk, Brankica; Karwal, Simrath; Serrano, Katherine; Levin, Elena; Bu, Daniel; Bhakta, Varsha; Sheffield, William P; Goodrich, Raymond P; Devine, Dana V

    2015-04-01

    Pathogen inactivation (PI) technologies are currently licensed for use with platelet (PLT) and plasma components. Treatment of whole blood (WB) would be of benefit to the blood banking community by saving time and costs compared to individual component treatment. However, no paired, pool-and-split study directly assessing the impact of WB PI on the subsequently produced components has yet been reported. In a "pool-and-split" study, WB either was treated with riboflavin and ultraviolet (UV) light or was kept untreated as control. The buffy coat (BC) method produced plasma, PLT, and red blood cell (RBC) components. PLT units arising from the untreated WB study arm were treated with riboflavin and UV light on day of production and compared to PLT concentrates (PCs) produced from the treated WB units. A panel of common in vitro variables for the three types of components was used to monitor quality throughout their respective storage periods. PCs derived from the WB PI treatment were of significantly better quality than treated PLT components for most variables. RBCs produced from the WB treatment deteriorated earlier during storage than untreated units. Plasma components showed a 3% to 44% loss in activity for several clotting factors. Treatment of WB with riboflavin and UV before production of components by the BC method shows a negative impact on all three blood components. PLT units produced from PI-treated WB exhibited less damage compared to PLT component treatment. © 2014 AABB.

  11. Thoracic Surgery Information on the Internet: A Multilingual Quality Assessment

    PubMed Central

    Davaris, Myles; Barnett, Stephen; Abouassaly, Robert

    2017-01-01

    Background Previous data suggest that quality of Internet information regarding surgical conditions and their treatments is variable. However, no comprehensive analysis of website quality exists for thoracic surgery. Objective The aim of this study was to quantify website quality in a multilingual setting using an international standard for assessment. Methods Health On the Net (HON) principles may be applied to websites using an automated toolbar function. We used the English, French, Spanish, and German Google search engines to identify 12,000 websites using keywords related to thoracic conditions and procedures. The first 150 websites returned by each keyword in each language were examined. We compared website quality to assess for tertile (is the quality better in first, second, or third 50 websites returned) and language differences. A further analysis of the English site types was undertaken performing a comparative analysis of website provider types. Results Overall, there are a considerable number of websites devoted to thoracic surgery: “lung cancer” returned over 150 million websites. About 7.85% (940/11,967) of websites are HON-accredited with differences by search term (P<.001) and tertiles (P<.001) of the first 150 websites, but not between languages. Oncological keywords regarding conditions and procedures were found to return a higher percentage of HON-accreditation. The percentage of HON-accredited sites was similar across all four languages (P=.77). In general, the first tertile contained a higher percentage of HON-accredited sites for every keyword. Conclusions Clinicians should appreciate the lack of validation of the majority of thoracic websites, with discrepancies in quality and number of websites across conditions and procedures. These differences appear similar regardless of language. An opportunity exists for clinicians to participate in the development of informative, ethical, and reliable health websites on the Internet and direct

  12. The effect of image quality, repeated study, and assessment method on anatomy learning.

    PubMed

    Fenesi, Barbara; Mackinnon, Chelsea; Cheng, Lucia; Kim, Joseph A; Wainman, Bruce C

    2017-06-01

    The use of two-dimensional (2D) images is consistently used to prepare anatomy students for handling real specimen. This study examined whether the quality of 2D images is a critical component in anatomy learning. The visual clarity and consistency of 2D anatomical images was systematically manipulated to produce low-quality and high-quality images of the human hand and human eye. On day 0, participants learned about each anatomical specimen from paper booklets using either low-quality or high-quality images, and then completed a comprehension test using either 2D images or three-dimensional (3D) cadaveric specimens. On day 1, participants relearned each booklet, and on day 2 participants completed a final comprehension test using either 2D images or 3D cadaveric specimens. The effect of image quality on learning varied according to anatomical content, with high-quality images having a greater effect on improving learning of hand anatomy than eye anatomy (high-quality vs. low-quality for hand anatomy P = 0.018; high-quality vs. low-quality for eye anatomy P = 0.247). Also, the benefit of high-quality images on hand anatomy learning was restricted to performance on short-answer (SA) questions immediately after learning (high-quality vs. low-quality on SA questions P = 0.018), but did not apply to performance on multiple-choice (MC) questions (high-quality vs. low-quality on MC questions P = 0.109) or after participants had an additional learning opportunity (24 hours later) with anatomy content (high vs. low on SA questions P = 0.643). This study underscores the limited impact of image quality on anatomy learning, and questions whether investment in enhancing image quality of learning aids significantly promotes knowledge development. Anat Sci Educ 10: 249-261. © 2016 American Association of Anatomists. © 2016 American Association of Anatomists.

  13. Prioritizing Information for Quality Improvement Using Resident Assessment Instrument Data: Experiences in One Canadian Province

    PubMed Central

    Sales, Anne; O'Rourke, Hannah M.; Draper, Kellie; Teare, Gary F.; Maxwell, Colleen

    2011-01-01

    Purpose: To elicit priority rankings of indicators of quality of care among providers and decision-makers in continuing care in Alberta, Canada. Methods: We used modified nominal group technique to elicit priorities and criteria for prioritization among the quality indicators and resident/client assessment protocols developed by the interRAI consortium for use in long-term care and home care. Results: The top-ranked items from the long-term care assessment data were pressure ulcers, pain and incontinence. The top-ranked items from the home care data were pain, falls and proportion of clients at high risk for residential placement. Participants considered a variety of issues in deciding how to rank the indicators. Implications: This work reflects the beginning of a process to better understand how providers and policy makers can work together to assess priorities for quality improvement within continuing care. PMID:22294992

  14. Teacher Quality and Quality Teaching: Examining the Relationship of a Teacher Assessment to Practice

    ERIC Educational Resources Information Center

    Hill, Heather C.; Umland, Kristin; Litke, Erica; Kapitula, Laura R.

    2012-01-01

    Multiple-choice assessments are frequently used for gauging teacher quality. However, research seldom examines whether results from such assessments generalize to practice. To illuminate this issue, we compare teacher performance on a mathematics assessment, during mathematics instruction, and by student performance on a state assessment. Poor…

  15. Automatic assessment of the quality of patient positioning in mammography

    NASA Astrophysics Data System (ADS)

    Bülow, Thomas; Meetz, Kirsten; Kutra, Dominik; Netsch, Thomas; Wiemker, Rafael; Bergtholdt, Martin; Sabczynski, Jörg; Wieberneit, Nataly; Freund, Manuela; Schulze-Wenck, Ingrid

    2013-02-01

    Quality assurance has been recognized as crucial for the success of population-based breast cancer screening programs using x-ray mammography. Quality guidelines and criteria have been defined in the US as well as the European Union in order to ensure the quality of breast cancer screening. Taplin et al. report that incorrect positioning of the breast is the major image quality issue in screening mammography. Consequently, guidelines and criteria for correct positioning and for the assessment of the positioning quality in mammograms play an important role in the quality standards. In this paper we present a system for the automatic evaluation of positioning quality in mammography according to the existing standardized criteria. This involves the automatic detection of anatomic landmarks in medio- lateral oblique (MLO) and cranio-caudal (CC) mammograms, namely the pectoral muscle, the mammilla and the infra-mammary fold. Furthermore, the detected landmarks are assessed with respect to their proper presentation in the image. Finally, the geometric relations between the detected landmarks are investigated to assess the positioning quality. This includes the evaluation whether the pectoral muscle is imaged down to the mammilla level, and whether the posterior nipple line diameter of the breast is consistent between the different views (MLO and CC) of the same breast. Results of the computerized assessment are compared to ground truth collected from two expert readers.

  16. Assessing Weight-Related Quality of Life in Adolescents

    PubMed Central

    Kolotkin, Ronette L.; Zeller, Meg; Modi, Avani C.; Samsa, Gregory P.; Quinlan, Nicole Polanichka; Yanovski, Jack A.; Bell, Stephen K.; Maahs, David M.; de Serna, Daniela Gonzales; Roehrig, Helmut R.

    2008-01-01

    Objective The development of a new weight-related measure to assess quality of life in adolescents [Impact of Weight on Quality of Life (IWQOL)-Kids] is described. Research Methods and Procedures Using a literature search, clinical experience, and consultation with pediatric clinicians, 73 items were developed, pilot tested, and administered to 642 participants, 11 to 19 years old, recruited from weight loss programs/studies and community samples (mean z-BMI, 1.5; range, –1.2 to 3.4; mean age, 14.0; 60% female; 56% white). Participants completed the 73 items and the Pediatric Quality of Life Inventory and were weighed and measured. Results Four factors (27 items) were identified (physical comfort, body esteem, social life, and family relations), accounting for 71% of the variance. The IWQOL-Kids demonstrated excellent psychometric properties. Internal consistency coefficients ranged from 0.88 to 0.95 for scales and equaled 0.96 for total score. Convergent validity was demonstrated with strong correlations between IWQOL-Kids total score and the Pediatric Quality of Life Inventory (r = 0.76, p < 0.0001). Significant differences were found across BMI groups and between clinical and community samples, supporting the sensitivity of this measure. Participants in a weight loss camp demonstrated improved IWQOL-Kids scores, suggesting responsiveness of the IWQOL-Kids to weight loss/social support intervention. Discussion The present study provides preliminary evidence regarding the psychometric properties of the IWQOL-Kids, a weight-related quality of life measure for adolescents. Given the rise of obesity in youth, the development of a reliable and valid weight-related measure of quality of life is timely. PMID:16648616

  17. Research Quality Assessment in Education: Impossible Science, Possible Art?

    ERIC Educational Resources Information Center

    Bridges, David

    2009-01-01

    For better or for worse, the assessment of research quality is one of the primary drivers of the behaviour of the academic community with all sorts of potential for distorting that behaviour. So, if you are going to assess research quality, how do you do it? This article explores some of the problems and possibilities, with particular reference to…

  18. Are patent medicine vendors effective agents in malaria control? Using lot quality assurance sampling to assess quality of practice in Jigawa, Nigeria.

    PubMed

    Berendes, Sima; Adeyemi, Olusegun; Oladele, Edward Adekola; Oresanya, Olusola Bukola; Okoh, Festus; Valadez, Joseph J

    2012-01-01

    Patent medicine vendors (PMV) provide antimalarial treatment and care throughout Sub-Saharan Africa, and can play an important role in the fight against malaria. Their close-to-client infrastructure could enable lifesaving artemisinin-based combination therapy (ACT) to reach patients in time. However, systematic assessments of drug sellers' performance quality are crucial if their role is to be managed within the health system. Lot quality assurance sampling (LQAS) could be an efficient method to monitor and evaluate PMV practice, but has so far never been used for this purpose. In support of the Nigeria Malaria Booster Program we assessed PMV practices in three Senatorial Districts (SDs) of Jigawa, Nigeria. A two-stage LQAS assessed whether at least 80% of PMV stores in SDs used national treatment guidelines. Acceptable sampling errors were set in consultation with government officials (alpha and beta <0.10). The hypergeometric formula determined sample sizes and cut-off values for SDs. A structured assessment tool identified high and low performing SDs for quality of care indicators. Drug vendors performed poorly in all SDs of Jigawa for all indicators. For example, all SDs failed for stocking and selling first-line antimalarials. PMV sold no longer recommended antimalarials, such as Chloroquine, Sulfadoxine-Pyrimethamine and oral Artesunate monotherapy. Most PMV were ignorant of and lacked training about new treatment guidelines that had endorsed ACTs as first-line treatment for uncomplicated malaria. There is urgent need to regularly monitor and improve the availability and quality of malaria treatment provided by medicine sellers in Nigeria; the irrational use of antimalarials in the ACT era revealed in this study bears a high risk of economic loss, death and development of drug resistance. LQAS has been shown to be a suitable method for monitoring malaria-related indicators among PMV, and should be applied in Nigeria and elsewhere to improve service delivery.

  19. Exploring the Notion of Quality in Quality Higher Education Assessment in a Collaborative Future

    ERIC Educational Resources Information Center

    Maguire, Kate; Gibbs, Paul

    2013-01-01

    The purpose of this article is to contribute to the debate on the notion of quality in higher education with particular focus on "objectifying through articulation" the assessment of quality by professional experts. The article gives an overview of the differentiations of quality as used in higher education. It explores a substantial…

  20. Quality Assessment of University Studies as a Service: Dimensions and Criteria

    ERIC Educational Resources Information Center

    Pukelyte, Rasa

    2010-01-01

    This article reviews a possibility to assess university studies as a service. University studies have to be of high quality both in their content and in the administrative level. Therefore, quality of studies as a service is an important constituent part of study quality assurance. When assessing quality of university studies as a service, it is…

  1. Prediction of ground water quality index to assess suitability for drinking purposes using fuzzy rule-based approach

    NASA Astrophysics Data System (ADS)

    Gorai, A. K.; Hasni, S. A.; Iqbal, Jawed

    2016-11-01

    Groundwater is the most important natural resource for drinking water to many people around the world, especially in rural areas where the supply of treated water is not available. Drinking water resources cannot be optimally used and sustained unless the quality of water is properly assessed. To this end, an attempt has been made to develop a suitable methodology for the assessment of drinking water quality on the basis of 11 physico-chemical parameters. The present study aims to select the fuzzy aggregation approach for estimation of the water quality index of a sample to check the suitability for drinking purposes. Based on expert's opinion and author's judgement, 11 water quality (pollutant) variables (Alkalinity, Dissolved Solids (DS), Hardness, pH, Ca, Mg, Fe, Fluoride, As, Sulphate, Nitrates) are selected for the quality assessment. The output results of proposed methodology are compared with the output obtained from widely used deterministic method (weighted arithmetic mean aggregation) for the suitability of the developed methodology.

  2. Assessing Volunteered Geographic Information (vgi) Quality Based on CONTRIBUTORS' Mapping Behaviours

    NASA Astrophysics Data System (ADS)

    Bégin, D.; Devillers, R.; Roche, S.

    2013-05-01

    VGI changed the mapping landscape by allowing people that are not professional cartographers to contribute to large mapping projects, resulting at the same time in concerns about the quality of the data produced. While a number of early VGI studies used conventional methods to assess data quality, such approaches are not always well adapted to VGI. Since VGI is a user-generated content, we posit that features and places mapped by contributors largely reflect contributors' personal interests. This paper proposes studying contributors' mapping processes to understand the characteristics and quality of the data produced. We argue that contributors' behaviour when mapping reflects contributors' motivation and individual preferences in selecting mapped features and delineating mapped areas. Such knowledge of contributors' behaviour could allow for the derivation of information about the quality of VGI datasets. This approach was tested using a sample area from OpenStreetMap, leading to a better understanding of data completeness for contributor's preferred features.

  3. Assessing Question Quality Using NLP

    ERIC Educational Resources Information Center

    Kopp, Kristopher J.; Johnson, Amy M.; Crossley, Scott A.; McNamara, Danielle S.

    2017-01-01

    An NLP algorithm was developed to assess question quality to inform feedback on questions generated by students within iSTART (an intelligent tutoring system that teaches reading strategies). A corpus of 4575 questions was coded using a four-level taxonomy. NLP indices were calculated for each question and machine learning was used to predict…

  4. Applying Argumentation Analysis To Assess the Quality of University Oceanography Students' Scientific Writing.

    ERIC Educational Resources Information Center

    Takao, Allison Y.; Prothero, William A.; Kelly, Gregory J.

    2002-01-01

    Presents the methods and results of an assessment of students' scientific writing. Studies an introductory oceanography course in a large public university that used an interactive CD-ROM, "Our Dynamic Planet". Analyzes the quality of students' written arguments by using a grading rubric and an argumentation analysis model. Includes 18…

  5. Using and Reporting the Delphi Method for Selecting Healthcare Quality Indicators: A Systematic Review

    PubMed Central

    Boulkedid, Rym; Abdoul, Hendy; Loustau, Marine; Sibony, Olivier; Alberti, Corinne

    2011-01-01

    Objective Delphi technique is a structured process commonly used to developed healthcare quality indicators, but there is a little recommendation for researchers who wish to use it. This study aimed 1) to describe reporting of the Delphi method to develop quality indicators, 2) to discuss specific methodological skills for quality indicators selection 3) to give guidance about this practice. Methodology and Main Finding Three electronic data bases were searched over a 30 years period (1978–2009). All articles that used the Delphi method to select quality indicators were identified. A standardized data extraction form was developed. Four domains (questionnaire preparation, expert panel, progress of the survey and Delphi results) were assessed. Of 80 included studies, quality of reporting varied significantly between items (9% for year's number of experience of the experts to 98% for the type of Delphi used). Reporting of methodological aspects needed to evaluate the reliability of the survey was insufficient: only 39% (31/80) of studies reported response rates for all rounds, 60% (48/80) that feedback was given between rounds, 77% (62/80) the method used to achieve consensus and 57% (48/80) listed quality indicators selected at the end of the survey. A modified Delphi procedure was used in 49/78 (63%) with a physical meeting of the panel members, usually between Delphi rounds. Median number of panel members was 17(Q1:11; Q3:31). In 40/70 (57%) studies, the panel included multiple stakeholders, who were healthcare professionals in 95% (38/40) of cases. Among 75 studies describing criteria to select quality indicators, 28 (37%) used validity and 17(23%) feasibility. Conclusion The use and reporting of the Delphi method for quality indicators selection need to be improved. We provide some guidance to the investigators to improve the using and reporting of the method in future surveys. PMID:21694759

  6. Using and reporting the Delphi method for selecting healthcare quality indicators: a systematic review.

    PubMed

    Boulkedid, Rym; Abdoul, Hendy; Loustau, Marine; Sibony, Olivier; Alberti, Corinne

    2011-01-01

    Delphi technique is a structured process commonly used to developed healthcare quality indicators, but there is a little recommendation for researchers who wish to use it. This study aimed 1) to describe reporting of the Delphi method to develop quality indicators, 2) to discuss specific methodological skills for quality indicators selection 3) to give guidance about this practice. Three electronic data bases were searched over a 30 years period (1978-2009). All articles that used the Delphi method to select quality indicators were identified. A standardized data extraction form was developed. Four domains (questionnaire preparation, expert panel, progress of the survey and Delphi results) were assessed. Of 80 included studies, quality of reporting varied significantly between items (9% for year's number of experience of the experts to 98% for the type of Delphi used). Reporting of methodological aspects needed to evaluate the reliability of the survey was insufficient: only 39% (31/80) of studies reported response rates for all rounds, 60% (48/80) that feedback was given between rounds, 77% (62/80) the method used to achieve consensus and 57% (48/80) listed quality indicators selected at the end of the survey. A modified Delphi procedure was used in 49/78 (63%) with a physical meeting of the panel members, usually between Delphi rounds. Median number of panel members was 17(Q1:11; Q3:31). In 40/70 (57%) studies, the panel included multiple stakeholders, who were healthcare professionals in 95% (38/40) of cases. Among 75 studies describing criteria to select quality indicators, 28 (37%) used validity and 17(23%) feasibility. The use and reporting of the Delphi method for quality indicators selection need to be improved. We provide some guidance to the investigators to improve the using and reporting of the method in future surveys.

  7. Quality assessment of butter cookies applying multispectral imaging

    PubMed Central

    Andresen, Mette S; Dissing, Bjørn S; Løje, Hanne

    2013-01-01

    A method for characterization of butter cookie quality by assessing the surface browning and water content using multispectral images is presented. Based on evaluations of the browning of butter cookies, cookies were manually divided into groups. From this categorization, reference values were calculated for a statistical prediction model correlating multispectral images with a browning score. The browning score is calculated as a function of oven temperature and baking time. It is presented as a quadratic response surface. The investigated process window was the intervals 4–16 min and 160–200°C in a forced convection electrically heated oven. In addition to the browning score, a model for predicting the average water content based on the same images is presented. This shows how multispectral images of butter cookies may be used for the assessment of different quality parameters. Statistical analysis showed that the most significant wavelengths for browning predictions were in the interval 400–700 nm and the wavelengths significant for water prediction were primarily located in the near-infrared spectrum. The water prediction model was found to correctly estimate the average water content with an absolute error of 0.22%. From the images it was also possible to follow the browning and drying propagation from the cookie edge toward the center. PMID:24804036

  8. Implementation of a hospital-based quality assessment program for rectal cancer.

    PubMed

    Hendren, Samantha; McKeown, Ellen; Morris, Arden M; Wong, Sandra L; Oerline, Mary; Poe, Lyndia; Campbell, Darrell A; Birkmeyer, Nancy J

    2014-05-01

    Quality improvement programs in Europe have had a markedly beneficial effect on the processes and outcomes of rectal cancer care. The quality of rectal cancer care in the United States is not as well understood, and scalable quality improvement programs have not been developed. The purpose of this article is to describe the implementation of a hospital-based quality assessment program for rectal cancer, targeting both community and academic hospitals. We recruited 10 hospitals from a surgical quality improvement organization. Nurse reviewers were trained to abstract rectal cancer data from hospital medical records, and abstracts were assessed for accuracy. We conducted two surveys to assess the training program and limitations of the data abstraction. We validated data completeness and accuracy by comparing hospital medical record and tumor registry data. Nine of 10 hospitals successfully performed abstractions with ≥ 90% accuracy. Experienced nurse reviewers were challenged by the technical details in operative and pathology reports. Although most variables had less than 10% missing data, outpatient testing information was lacking from some hospitals' inpatient records. This implementation project yielded a final quality assessment program consisting of 20 medical records variables and 11 tumor registry variables. An innovative program linking tumor registry data to quality-improvement data for rectal cancer quality assessment was successfully implemented in 10 hospitals. This data platform and training program can serve as a template for other organizations that are interested in assessing and improving the quality of rectal cancer care. Copyright © 2014 by American Society of Clinical Oncology.

  9. National Water-Quality Assessment Program: Central Arizona Basins

    USGS Publications Warehouse

    Cordy, Gail E.

    1994-01-01

    In 1991, the U.S. Geological Survey (USGS) began to implement a full-scale National Water-Quality Assessment (NAWQA) program. The long-term goals of the NAWQA program are to describe the status and trends in the quality of a large, representative part of the Nation's surface-water and ground-water resources and to provide a sound, scientific understanding of the primary natural and human factors affecting the quality of these resources. In meeting these goals, the program will produce a wealth of water-quality information that will be useful to policymakers and managers at the National, State, and local levels. Studies of 60 hydrologic systems that include parts of most major river basins and aquifer systems (study-unit investigations) are the building blocks of the national assessment. The 60 study units range in size from 1,000 to about 60,000 mi2 and represent 60 to 70 percent of the Nation's water use and population served by public water supplies. Twenty study-unit investigations were started in 1991, 20 additional studies started in 1994, and 20 more are planned to start in 1997. The Central Arizona Basins study unit began assessment activities in 1994.

  10. Comparison of laboratory and field remote sensing methods to measure forage quality.

    PubMed

    Guo, Xulin; Wilmshurst, John F; Li, Zhaoqin

    2010-09-01

    Recent research in range ecology has emphasized the importance of forage quality as a key indicator of rangeland condition. However, we lack tools to evaluate forage quality at scales appropriate for management. Using canopy reflectance data to measure forage quality has been conducted at both laboratory and field levels separately, but little work has been conducted to evaluate these methods simultaneously. The objective of this study is to find a reliable way of assessing grassland quality through measuring forage chemistry with reflectance. We studied a mixed grass ecosystem in Grasslands National Park of Canada and surrounding pastures, located in southern Saskatchewan. Spectral reflectance was collected at both in-situ field level and in the laboratory. Vegetation samples were collected at each site, sorted into the green grass portion, and then sent to a chemical company for measuring forage quality variables, including protein, lignin, ash, moisture at 135 °C, Neutral Detergent Fiber (NDF), Acid Detergent Fiber (ADF), Total Digestible, Digestible Energy, Net Energy for Lactation, Net Energy for Maintenance, and Net Energy for Gain. Reflectance data were processed with the first derivative transformation and continuum removal method. Correlation analysis was conducted on spectral and forage quality variables. A regression model was further built to investigate the possibility of using canopy spectral measurements to predict the grassland quality. Results indicated that field level prediction of protein of mixed grass species was possible (r² = 0.63). However, the relationship between canopy reflectance and the other forage quality variables was not strong.

  11. The application of intraoperative transit time flow measurement to accurately assess anastomotic quality in sequential vein grafting

    PubMed Central

    Yu, Yang; Zhang, Fan; Gao, Ming-Xin; Li, Hai-Tao; Li, Jing-Xing; Song, Wei; Huang, Xin-Sheng; Gu, Cheng-Xiong

    2013-01-01

    OBJECTIVES Intraoperative transit time flow measurement (TTFM) is widely used to assess anastomotic quality in coronary artery bypass grafting (CABG). However, in sequential vein grafting, the flow characteristics collected by the conventional TTFM method are usually associated with total graft flow and might not accurately indicate the quality of every distal anastomosis in a sequential graft. The purpose of our study was to examine a new TTFM method that could assess the quality of each distal anastomosis in a sequential graft more reliably than the conventional TTFM approach. METHODS Two TTFM methods were tested in 84 patients who underwent sequential saphenous off-pump CABG in Beijing An Zhen Hospital between April and August 2012. In the conventional TTFM method, normal blood flow in the sequential graft was maintained during the measurement, and the flow probe was placed a few centimetres above the anastomosis to be evaluated. In the new method, blood flow in the sequential graft was temporarily reduced during the measurement by placing an atraumatic bulldog clamp at the graft a few centimetres distal to the anastomosis to be evaluated, while the position of the flow probe remained the same as in the conventional method. This new TTFM method was named the flow reduction TTFM. Graft flow parameters measured by both methods were compared. RESULTS Compared with the conventional TTFM, the flow reduction TTFM resulted in significantly lower mean graft blood flow (P < 0.05); in contrast, yielded significantly higher pulsatility index (P < 0.05). Diastolic filling was not significantly different between the two methods and was >50% in both cases. Interestingly, the flow reduction TTFM identified two defective middle distal anastomoses that the conventional TTFM failed to detect. Graft flows near the defective distal anastomoses were improved substantially after revision. CONCLUSIONS In this study, we found that temporary reduction of graft flow during TTFM seemed to

  12. Michigan lakes: An assessment of water quality

    USGS Publications Warehouse

    Minnerick, R.J.

    2004-01-01

    Michigan has more than 11,000 inland lakes, that provide countless recreational opportunities and are an important resource that makes tourism and recreation a $15-billion-dollar per-year industry in the State (Stynes, 2002). Knowledge of the water-quality characteristics of inland lakes is essential for the current and future management of these resources.Historically the U. S. Geological Survey (USGS) and the Michigan Department of Environmental Quality (MDEQ) jointly have monitored water quality in Michigan's lakes and rivers. During the 1990's, however, funding for surface-water-quality monitoring was reduced greatly. In 1998, the citizens of Michigan passed the Clean Michigan Initiative to clean up, protect, and enhance Michigan's environmental infrastructure. Because of expanding water-quality-data needs, the MDEQ and the USGS jointly redesigned and implemented the Lake Water-Quality Assessment (LWQA) Monitoring Program (Michigan Department of Environmental Quality, 1997).

  13. Validity of portfolio assessment: which qualities determine ratings?

    PubMed

    Driessen, Erik W; Overeem, Karlijn; van Tartwijk, Jan; van der Vleuten, Cees P M; Muijtjens, Arno M M

    2006-09-01

    The portfolio is becoming increasingly accepted as a valuable tool for learning and assessment. The validity of portfolio assessment, however, may suffer from bias due to irrelevant qualities, such as lay-out and writing style. We examined the possible effects of such qualities in a portfolio programme aimed at stimulating Year 1 medical students to reflect on their professional and personal development. In later curricular years, this portfolio is also used to judge clinical competence. We developed an instrument, the Portfolio Analysis Scoring Inventory, to examine the impact of form and content aspects on portfolio assessment. The Inventory consists of 15 items derived from interviews with experienced mentors, the literature, and the criteria for reflective competence used in the regular portfolio assessment procedure. Forty portfolios, selected from 231 portfolios for which ratings from the regular assessment procedure were available, were rated by 2 researchers, independently, using the Inventory. Regression analysis was used to estimate the correlation between the ratings from the regular assessment and those resulting from the Inventory items. Inter-rater agreement ranged from 0.46 to 0.87. The strongest predictor of the variance in the regular ratings was 'quality of reflection' (R 0.80; R2 66%). No further items accounted for a significant proportion of variance. Irrelevant items, such as writing style and lay-out, had negligible effects. The absence of an impact of irrelevant criteria appears to support the validity of the portfolio assessment procedure. Further studies should examine the portfolio's validity for the assessment of clinical competence.

  14. Groundwater-quality data from the National Water-Quality Assessment Project, January through December 2014 and select quality-control data from May 2012 through December 2014

    USGS Publications Warehouse

    Arnold, Terri L.; Bexfield, Laura M.; Musgrove, MaryLynn; Lindsey, Bruce D.; Stackelberg, Paul E.; Barlow, Jeannie R.; Desimone, Leslie A.; Kulongoski, Justin T.; Kingsbury, James A.; Ayotte, Joseph D.; Fleming, Brandon J.; Belitz, Kenneth

    2017-10-05

    Groundwater-quality data were collected from 559 wells as part of the National Water-Quality Assessment Project of the U.S. Geological Survey National Water-Quality Program from January through December 2014. The data were collected from four types of well networks: principal aquifer study networks, which are used to assess the quality of groundwater used for public water supply; land-use study networks, which are used to assess land-use effects on shallow groundwater quality; major aquifer study networks, which are used to assess the quality of groundwater used for domestic supply; and enhanced trends networks, which are used to evaluate the time scales during which groundwater quality changes. Groundwater samples were analyzed for a large number of water-quality indicators and constituents, including major ions, nutrients, trace elements, volatile organic compounds, pesticides, radionuclides, and some constituents of special interest (arsenic speciation, chromium [VI] and perchlorate). These groundwater-quality data, along with data from quality-control samples, are tabulated in this report and in an associated data release.

  15. Monitoring and Assessment of Youshui River Water Quality in Youyang

    NASA Astrophysics Data System (ADS)

    Wang, Xue-qin; Wen, Juan; Chen, Ping-hua; Liu, Na-na

    2018-02-01

    By monitoring the water quality of Youshui River from January 2016 to December 2016, according to the indicator grading and the assessment standard of water quality, the formulas for 3 types water quality indexes are established. These 3 types water quality indexes, the single indicator index Ai, single moment index Ak and the comprehensive water quality index A, were used to quantitatively evaluate the quality of single indicator, the water quality and the change of water quality with time. The results show that, both total phosphorus and fecal coliform indicators exceeded the standard, while the other 16 indicators measured up to the standard. The water quality index of Youshui River is 0.93 and the grade of water quality comprehensive assessment is level 2, which indicated that the water quality of Youshui River is good, and there is room for further improvement. To this end, several protection measures for Youshui River environmental management and pollution treatment are proposed.

  16. Assessing Quality in Graduate Programs: An Internal Quality Indicator. AIR Forum 1981 Paper.

    ERIC Educational Resources Information Center

    DiBiasio, Daniel A.; And Others

    Four approaches to measuring quality in graduate education are reviewed, and the approach used at the graduate school at Ohio State University is assessed. Four approaches found in the literature are: measuring quality by reputation, by scholarly productivity, by correlating reputation and scholarly productivity, and by multiple measures. Ohio…

  17. Objective Video Quality Assessment Based on Machine Learning for Underwater Scientific Applications

    PubMed Central

    Moreno-Roldán, José-Miguel; Luque-Nieto, Miguel-Ángel; Poncela, Javier; Otero, Pablo

    2017-01-01

    Video services are meant to be a fundamental tool in the development of oceanic research. The current technology for underwater networks (UWNs) imposes strong constraints in the transmission capacity since only a severely limited bitrate is available. However, previous studies have shown that the quality of experience (QoE) is enough for ocean scientists to consider the service useful, although the perceived quality can change significantly for small ranges of variation of video parameters. In this context, objective video quality assessment (VQA) methods become essential in network planning and real time quality adaptation fields. This paper presents two specialized models for objective VQA, designed to match the special requirements of UWNs. The models are built upon machine learning techniques and trained with actual user data gathered from subjective tests. Our performance analysis shows how both of them can successfully estimate quality as a mean opinion score (MOS) value and, for the second model, even compute a distribution function for user scores. PMID:28333123

  18. Identification and assessment of potential water quality impact factors for drinking-water reservoirs.

    PubMed

    Gu, Qing; Deng, Jinsong; Wang, Ke; Lin, Yi; Li, Jun; Gan, Muye; Ma, Ligang; Hong, Yang

    2014-06-10

    Various reservoirs have been serving as the most important drinking water sources in Zhejiang Province, China, due to the uneven distribution of precipitation and severe river pollution. Unfortunately, rapid urbanization and industrialization have been continuously challenging the water quality of the drinking-water reservoirs. The identification and assessment of potential impacts is indispensable in water resource management and protection. This study investigates the drinking water reservoirs in Zhejiang Province to better understand the potential impact on water quality. Altogether seventy-three typical drinking reservoirs in Zhejiang Province encompassing various water storage levels were selected and evaluated. Using fifty-two reservoirs as training samples, the classification and regression tree (CART) method and sixteen comprehensive variables, including six sub-sets (land use, population, socio-economy, geographical features, inherent characteristics, and climate), were adopted to establish a decision-making model for identifying and assessing their potential impacts on drinking-water quality. The water quality class of the remaining twenty-one reservoirs was then predicted and tested based on the decision-making model, resulting in a water quality class attribution accuracy of 81.0%. Based on the decision rules and quantitative importance of the independent variables, industrial emissions was identified as the most important factor influencing the water quality of reservoirs; land use and human habitation also had a substantial impact on water quality. The results of this study provide insights into the factors impacting the water quality of reservoirs as well as basic information for protecting reservoir water resources.

  19. Display device-adapted video quality-of-experience assessment

    NASA Astrophysics Data System (ADS)

    Rehman, Abdul; Zeng, Kai; Wang, Zhou

    2015-03-01

    Today's viewers consume video content from a variety of connected devices, including smart phones, tablets, notebooks, TVs, and PCs. This imposes significant challenges for managing video traffic efficiently to ensure an acceptable quality-of-experience (QoE) for the end users as the perceptual quality of video content strongly depends on the properties of the display device and the viewing conditions. State-of-the-art full-reference objective video quality assessment algorithms do not take into account the combined impact of display device properties, viewing conditions, and video resolution while performing video quality assessment. We performed a subjective study in order to understand the impact of aforementioned factors on perceptual video QoE. We also propose a full reference video QoE measure, named SSIMplus, that provides real-time prediction of the perceptual quality of a video based on human visual system behaviors, video content characteristics (such as spatial and temporal complexity, and video resolution), display device properties (such as screen size, resolution, and brightness), and viewing conditions (such as viewing distance and angle). Experimental results have shown that the proposed algorithm outperforms state-of-the-art video quality measures in terms of accuracy and speed.

  20. A new statistical framework to assess structural alignment quality using information compression

    PubMed Central

    Collier, James H.; Allison, Lloyd; Lesk, Arthur M.; Garcia de la Banda, Maria; Konagurthu, Arun S.

    2014-01-01

    Motivation: Progress in protein biology depends on the reliability of results from a handful of computational techniques, structural alignments being one. Recent reviews have highlighted substantial inconsistencies and differences between alignment results generated by the ever-growing stock of structural alignment programs. The lack of consensus on how the quality of structural alignments must be assessed has been identified as the main cause for the observed differences. Current methods assess structural alignment quality by constructing a scoring function that attempts to balance conflicting criteria, mainly alignment coverage and fidelity of structures under superposition. This traditional approach to measuring alignment quality, the subject of considerable literature, has failed to solve the problem. Further development along the same lines is unlikely to rectify the current deficiencies in the field. Results: This paper proposes a new statistical framework to assess structural alignment quality and significance based on lossless information compression. This is a radical departure from the traditional approach of formulating scoring functions. It links the structural alignment problem to the general class of statistical inductive inference problems, solved using the information-theoretic criterion of minimum message length. Based on this, we developed an efficient and reliable measure of structural alignment quality, I-value. The performance of I-value is demonstrated in comparison with a number of popular scoring functions, on a large collection of competing alignments. Our analysis shows that I-value provides a rigorous and reliable quantification of structural alignment quality, addressing a major gap in the field. Availability: http://lcb.infotech.monash.edu.au/I-value Contact: arun.konagurthu@monash.edu Supplementary information: Online supplementary data are available at http://lcb.infotech.monash.edu.au/I-value/suppl.html PMID:25161241

  1. Automated Quality Assessment of Colour Fundus Images for Diabetic Retinopathy Screening in Telemedicine.

    PubMed

    Saha, Sajib Kumar; Fernando, Basura; Cuadros, Jorge; Xiao, Di; Kanagasingam, Yogesan

    2018-04-27

    Fundus images obtained in a telemedicine program are acquired at different sites that are captured by people who have varying levels of experience. These result in a relatively high percentage of images which are later marked as unreadable by graders. Unreadable images require a recapture which is time and cost intensive. An automated method that determines the image quality during acquisition is an effective alternative. To determine the image quality during acquisition, we describe here an automated method for the assessment of image quality in the context of diabetic retinopathy. The method explicitly applies machine learning techniques to access the image and to determine 'accept' and 'reject' categories. 'Reject' category image requires a recapture. A deep convolution neural network is trained to grade the images automatically. A large representative set of 7000 colour fundus images was used for the experiment which was obtained from the EyePACS that were made available by the California Healthcare Foundation. Three retinal image analysis experts were employed to categorise these images into 'accept' and 'reject' classes based on the precise definition of image quality in the context of DR. The network was trained using 3428 images. The method shows an accuracy of 100% to successfully categorise 'accept' and 'reject' images, which is about 2% higher than the traditional machine learning method. On a clinical trial, the proposed method shows 97% agreement with human grader. The method can be easily incorporated with the fundus image capturing system in the acquisition centre and can guide the photographer whether a recapture is necessary or not.

  2. Quality Management Plan for the Environmental Assessment and Innovation Division

    EPA Pesticide Factsheets

    Quality management plan (QMP) which identifies the mission, roles, responsibilities of personnel with regard to quality assurance and quality management for the environmental assessment and innovation division.

  3. Where is information quality lost at clinical level? A mixed-method study on information systems and data quality in three urban Kenyan ANC clinics

    PubMed Central

    Hahn, Daniel; Wanjala, Pepela; Marx, Michael

    2013-01-01

    Background Well-working health information systems are considered vital with the quality of health data ranked of highest importance for decision making at patient care and policy levels. In particular, health facilities play an important role, since they are not only the entry point for the national health information system but also use health data (and primarily) for patient care. Design A multiple case study was carried out between March and August 2012 at the antenatal care (ANC) clinics of two private and one public Kenyan hospital to describe clinical information systems and assess the quality of information. The following methods were developed and employed in an iterative process: workplace walkthroughs, structured and in-depth interviews with staff members, and a quantitative assessment of data quality (completeness and accurate transmission of clinical information and reports in ANC). Views of staff and management on the quality of employed information systems, data quality, and influencing factors were captured qualitatively. Results Staff rated the quality of information higher in the private hospitals employing computers than in the public hospital which relies on paper forms. Several potential threats to data quality were reported. Limitations in data quality were common at all study sites including wrong test results, missing registers, and inconsistencies in reports. Feedback was seldom on content or quality of reports and usage of data beyond individual patient care was low. Conclusions We argue that the limited data quality has to be seen in the broader perspective of the information systems in which it is produced and used. The combination of different methods has proven to be useful for this. To improve the effectiveness and capabilities of these systems, combined measures are needed which include technical and organizational aspects (e.g. regular feedback to health workers) and individual skills and motivation. PMID:23993022

  4. Where is information quality lost at clinical level? A mixed-method study on information systems and data quality in three urban Kenyan ANC clinics.

    PubMed

    Hahn, Daniel; Wanjala, Pepela; Marx, Michael

    2013-08-29

    Well-working health information systems are considered vital with the quality of health data ranked of highest importance for decision making at patient care and policy levels. In particular, health facilities play an important role, since they are not only the entry point for the national health information system but also use health data (and primarily) for patient care. A multiple case study was carried out between March and August 2012 at the antenatal care (ANC) clinics of two private and one public Kenyan hospital to describe clinical information systems and assess the quality of information. The following methods were developed and employed in an iterative process: workplace walkthroughs, structured and in-depth interviews with staff members, and a quantitative assessment of data quality (completeness and accurate transmission of clinical information and reports in ANC). Views of staff and management on the quality of employed information systems, data quality, and influencing factors were captured qualitatively. Staff rated the quality of information higher in the private hospitals employing computers than in the public hospital which relies on paper forms. Several potential threats to data quality were reported. Limitations in data quality were common at all study sites including wrong test results, missing registers, and inconsistencies in reports. Feedback was seldom on content or quality of reports and usage of data beyond individual patient care was low. We argue that the limited data quality has to be seen in the broader perspective of the information systems in which it is produced and used. The combination of different methods has proven to be useful for this. To improve the effectiveness and capabilities of these systems, combined measures are needed which include technical and organizational aspects (e.g. regular feedback to health workers) and individual skills and motivation.

  5. Methods for assessment of keel bone damage in poultry.

    PubMed

    Casey-Trott, T; Heerkens, J L T; Petrik, M; Regmi, P; Schrader, L; Toscano, M J; Widowski, T

    2015-10-01

    Keel bone damage (KBD) is a critical issue facing the laying hen industry today as a result of the likely pain leading to compromised welfare and the potential for reduced productivity. Recent reports suggest that damage, while highly variable and likely dependent on a host of factors, extends to all systems (including battery cages, furnished cages, and non-cage systems), genetic lines, and management styles. Despite the extent of the problem, the research community remains uncertain as to the causes and influencing factors of KBD. Although progress has been made investigating these factors, the overall effort is hindered by several issues related to the assessment of KBD, including quality and variation in the methods used between research groups. These issues prevent effective comparison of studies, as well as difficulties in identifying the presence of damage leading to poor accuracy and reliability. The current manuscript seeks to resolve these issues by offering precise definitions for types of KBD, reviewing methods for assessment, and providing recommendations that can improve the accuracy and reliability of those assessments. © 2015 Poultry Science Association Inc.

  6. [Ecological environmental quality assessment of Hangzhou urban area based on RS and GIS].

    PubMed

    Xu, Pengwei; Zhao, Duo

    2006-06-01

    In allusion to the shortage of traditional ecological environmental quality assessment, this paper studied the spatial distribution of assessing factors at a mid-small scale, and the conversion of integer character to girding assessing cells. The main assessing factors including natural environmental condition, environmental quality, natural landscape and urbanization pressure, which were classified into four types with about eleven assessing factors, were selected from RS images and GIS-spatial analyzing environmental quality vector graph. Based on GIS, a comprehensive assessment model for the ecological environmental quality in Hangzhou urban area was established. In comparison with observed urban heat island effects, the assessment results were in good agreement with the ecological environmental quality in the urban area of Hangzhou.

  7. 42 CFR 438.240 - Quality assessment and performance improvement program.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 4 2011-10-01 2011-10-01 false Quality assessment and performance improvement program. 438.240 Section 438.240 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL ASSISTANCE PROGRAMS MANAGED CARE Quality Assessment and...

  8. 42 CFR 438.240 - Quality assessment and performance improvement program.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 4 2013-10-01 2013-10-01 false Quality assessment and performance improvement program. 438.240 Section 438.240 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL ASSISTANCE PROGRAMS MANAGED CARE Quality Assessment and...

  9. 42 CFR 438.240 - Quality assessment and performance improvement program.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 4 2012-10-01 2012-10-01 false Quality assessment and performance improvement program. 438.240 Section 438.240 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL ASSISTANCE PROGRAMS MANAGED CARE Quality Assessment and...

  10. 42 CFR 438.240 - Quality assessment and performance improvement program.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 4 2014-10-01 2014-10-01 false Quality assessment and performance improvement program. 438.240 Section 438.240 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL ASSISTANCE PROGRAMS MANAGED CARE Quality Assessment and...

  11. Image quality assessment by preprocessing and full reference model combination

    NASA Astrophysics Data System (ADS)

    Bianco, S.; Ciocca, G.; Marini, F.; Schettini, R.

    2009-01-01

    This paper focuses on full-reference image quality assessment and presents different computational strategies aimed to improve the robustness and accuracy of some well known and widely used state of the art models, namely the Structural Similarity approach (SSIM) by Wang and Bovik and the S-CIELAB spatial-color model by Zhang and Wandell. We investigate the hypothesis that combining error images with a visual attention model could allow a better fit of the psycho-visual data of the LIVE Image Quality assessment Database Release 2. We show that the proposed quality assessment metric better correlates with the experimental data.

  12. Multi-frame super-resolution with quality self-assessment for retinal fundus videos.

    PubMed

    Köhler, Thomas; Brost, Alexander; Mogalle, Katja; Zhang, Qianyi; Köhler, Christiane; Michelson, Georg; Hornegger, Joachim; Tornow, Ralf P

    2014-01-01

    This paper proposes a novel super-resolution framework to reconstruct high-resolution fundus images from multiple low-resolution video frames in retinal fundus imaging. Natural eye movements during an examination are used as a cue for super-resolution in a robust maximum a-posteriori scheme. In order to compensate heterogeneous illumination on the fundus, we integrate retrospective illumination correction for photometric registration to the underlying imaging model. Our method utilizes quality self-assessment to provide objective quality scores for reconstructed images as well as to select regularization parameters automatically. In our evaluation on real data acquired from six human subjects with a low-cost video camera, the proposed method achieved considerable enhancements of low-resolution frames and improved noise and sharpness characteristics by 74%. In terms of image analysis, we demonstrate the importance of our method for the improvement of automatic blood vessel segmentation as an example application, where the sensitivity was increased by 13% using super-resolution reconstruction.

  13. Floristic quality assessment of one natural and three restored wetland complexes in North Dakota, USA

    USGS Publications Warehouse

    Mushet, David M.; Euliss, Ned H.; Shaffer, Terry L.

    2002-01-01

    Floristic quality assessment is potentially an important tool for conservation efforts in the northern Great Plains of North America, but it has received little rigorous evaluation. Floristic quality assessments rely on coefficients assigned to each plant species of a region’s flora based on the conservatism of each species relative to others in the region. These “coefficients of conservatism” (C values) are assigned by a panel of experts familiar with a region’s flora. The floristic quality assessment method has faced some criticism due to the subjective nature of these assignments. To evaluate the effect of this subjectivity on floristic quality assessments, we performed separate evaluations of the native plant communities in a natural wetland complex and three restored wetland complexes. In our first assessment, we used C values assigned “subjectively” by the Northern Great Plains Floristic Quality Assessment Panel. We then performed an independent assessment using the observed distributions of species among a group of wetlands that ranged from highly disturbed to largely undisturbed (data-generated C values). Using the panel-assigned C values, mean C values (C¯">C¯C¯) of the restored wetlands rarely exceeded 3.4 and never exceeded 3.9, with the highest values occurring in the oldest restored complex; all but two wetlands in the natural wetland complex had a C¯">C¯C¯ greater than 3.9. Floristic quality indices (FQI) for the restored wetlands rarely exceeded 22 and usually reached maximums closer to 19, with higher values occurring again in the oldest restored complex; only two wetlands in the natural complex had an FQI less than 22. We observed that 95% confidence limits for species richness and percent natives overlapped greatly among wetland complexes, whereas confidence limits for both C¯">C¯C¯ and FQI overlapped little. C¯">C¯C¯ and FQI values were consistently greater when we used the datagenerated C values than when we used the

  14. [Risk adjusted assessment of quality of perinatal centers - results of perinatal/neonatal quality surveillance in Saxonia].

    PubMed

    Koch, R; Gmyrek, D; Vogtmann, Ch

    2005-12-01

    The weak point of the country-wide perinatal/neonatal quality surveillance as a tool for evaluation of achievements of a distinct clinic, is the ignorance of interhospital differences in the case-mix of patients. Therefore, that approach can not result in a reliable bench marking. To adjust the results of quality assessment of different hospitals according to their risk profile of patients by multivariate analysis. The perinatal/neonatal data base of 12.783 newborns of the saxonian quality surveillance from 1998 to 2000 was analyzed. 4 relevant quality indicators of newborn outcome -- a) severe intraventricular hemorrhage in preterm infants < 1500 g, b) death in hospital of preterm infants < 1500 g, c) death in newborns with birth weight > 2500 g and d) hypoxic-ischemic encephalopathy -- were targeted to find out specific risk predictors by considering 26 risk factors. A logistic regression model was used to develop the risk predictors. Risk predictors for the 4 quality indicators could be described by 3 - 9 out of 26 analyzed risk factors. The AUC (ROC)-values for these quality indicators were 82, 89, 89 and 89 %, what signifies their reliability. Using the new specific predictors for calculation the risk adjusted incidence rates of quality indicator yielded in some remarkable changes. The apparent differences in the outcome criteria of analyzed hospitals were found to be much less pronounced. The application of the proposed method for risk adjustment of quality indicators makes it possible to perform a more objective comparison of neonatal outcome criteria between different hospitals or regions.

  15. Microbiological monitoring for the US Geological Survey National Water-Quality Assessment Program

    USGS Publications Warehouse

    Francy, Donna S.; Myers, Donna N.; Helsel, Dennis R.

    2000-01-01

    Data to characterize the microbiological quality of the Nation?s fresh, marine, and estuarine waters are usually collected for local purposes, most often to judge compliance with standards for protection of public health in swimmable or drinkable waters. Methods and procedures vary with the objectives and practices of the parties collecting data and are continuously being developed or modified. Therefore, it is difficult to provide a nationally consistent picture of the microbial quality of the Nation?s waters. Study objectives and guidelines for a national microbiological monitoring program are outlined in this report, using the framework of the U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) program. A national program is designed to provide long-term data on the presence of microbiological pathogens and indicators in ground water and surface water to support effective water policy and management. Three major groups of waterborne pathogens affect the public health acceptability of waters in the United States?bacteria, protozoa, and viruses. Microbiological monitoring in NAWQA would be designed to assess the occurrence, distribution, and trends of pathogenic organisms and indicators in surface waters and ground waters; relate the patterns discerned to factors that help explain them; and improve our understanding of the processes that control microbiological water quality.

  16. Bioassay selection, experimental design and quality control/assurance for use in effluent assessment and control.

    PubMed

    Johnson, Ian; Hutchings, Matt; Benstead, Rachel; Thain, John; Whitehouse, Paul

    2004-07-01

    In the UK Direct Toxicity Assessment Programme, carried out in 1998-2000, a series of internationally recognised short-term toxicity test methods for algae, invertebrates and fishes, and rapid methods (ECLOX and Microtox) were used extensively. Abbreviated versions of conventional tests (algal growth inhibition tests, Daphnia magna immobilisation test and the oyster embryo-larval development test) were valuable for toxicity screening of effluent discharges and the identification of causes and sources of toxicity. Rapid methods based on chemiluminescence and bioluminescence were not generally useful in this programme, but may have a role where the rapid test has been shown to be an acceptable surrogate for a standardised test method. A range of quality assurance and control measures were identified. Requirements for quality control/assurance are most stringent when deriving data for characterising the toxic hazards of effluents and monitoring compliance against a toxicity reduction target. Lower quality control/assurance requirements can be applied to discharge screening and the identification of causes and sources of toxicity.

  17. Monitoring River Water Levels from Space: Quality Assessment of 20 Years of Satellite Altimetry Data

    NASA Astrophysics Data System (ADS)

    Bercher, Nicolas; Kosuth, Pascal

    2013-09-01

    This paper presents the results of 20 years of validation of altimetry data for the monitoring of river water levels using a standardized method. The method was initially developed by Cemagref (2006-2011, [5, 6, 3]), now Irste ´a, its implementation is now pursued at LEGOS.Our initial statement was: "what if someone1 wants to use satellite measurements of river water levels ?" The obvious question that comes to mind is "what the quality of the data ?". Moreover, there's also a need - a demand from data producers, to monitor products quality in a standardized fashion.We addressed such questions and have developped a method to assess the quality of, so called, "Alti-Hydro Products". The method was implemented for the following Alti-Hydro products (and automatically derived from a L2 product*) : AVISO* (Topex/Poseidon, Jason-2), CASH project (Topex/Poseidon), HydroWeb (Topex/Poseidon, ENVISAT), River & Lake Hydrology (ERS-2, ENVISAT) and PISTACH* (Jason-2).

  18. Effectiveness Comparison of TxDOT Quality Control/Quality Assurance and Method Specifications

    DOT National Transportation Integrated Search

    1998-12-01

    Original Report date: October 1997. This is the first and final report for research project 0-1721, "Effectiveness Comparison of TxDOT Quality Control/Quality Assurance and Method Specifications." This study was established and sponsored by TxDOT to ...

  19. 42 CFR 438.240 - Quality assessment and performance improvement program.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Quality assessment and performance improvement... Performance Improvement Measurement and Improvement Standards § 438.240 Quality assessment and performance improvement program. (a) General rules. (1) The State must require, through its contracts, that each MCO and...

  20. The practical application of signal detection theory to image quality assessment in x-ray image intensifier-TV fluoroscopy.

    PubMed

    Marshall, N W

    2001-06-01

    This paper applies a published version of signal detection theory to x-ray image intensifier fluoroscopy data and compares the results with more conventional subjective image quality measures. An eight-bit digital framestore was used to acquire temporally contiguous frames of fluoroscopy data from which the modulation transfer function (MTF(u)) and noise power spectrum were established. These parameters were then combined to give detective quantum efficiency (DQE(u)) and used in conjunction with signal detection theory to calculate contrast-detail performance. DQE(u) was found to lie between 0.1 and 0.5 for a range of fluoroscopy systems. Two separate image quality experiments were then performed in order to assess the correspondence between the objective and subjective methods. First, image quality for a given fluoroscopy system was studied as a function of doserate using objective parameters and a standard subjective contrast-detail method. Following this, the two approaches were used to assess three different fluoroscopy units. Agreement between objective and subjective methods was good; doserate changes were modelled correctly while both methods ranked the three systems consistently.

  1. A Simple and Rapid UPLC-PDA Method for Quality Control of Nardostachys jatamansi.

    PubMed

    Zhang, Weize; Nan, Guo; Wu, Hong-Hua; Jiang, Miaomiao; Li, Tian-Xiang; Wang, Meng; Gao, Xiu-Mei; Zhu, Yan; Song, Yun Seon; Wang, Jiaming; Xu, Yan-Tong

    2018-05-01

    Nardostachys jatamansi is a well-documented herbal agent used to treat digestive and neuropsychiatric disorders in oriental medicinal systems. However, few simple, rapid, and comprehensive methods were reported for quality assessment and control of N. jatamansi . Herein, a UPLC with photodiode array detection method was developed for both fingerprint investigation of N. jatamansi and simultaneous quantitative analysis of the six serotonin transporter modulatory constituents in N. jatamansi . For chromatographic fingerprinting, 24 common peaks were selected as characteristic peaks to assess the consistency of N. jatamansi samples from different retail sources. Six of the common peaks (5, 7, 12: , and 16:  - 18: ) were identified as desoxo-narchinol A, buddleoside, isonardosinone, nardosinone, kanshone H, and (-)-aristolone, respectively, by phytochemical investigation. Five of the six compounds significantly either enhanced or inhibited serotonin transporter activity, while (-)-aristolone (18: ) didn't show any serotonin transporter activity. In quantitative analysis, the six compounds showed good linearity ( r  > 0.999) within test ranges. The precision, expressed as relative standard deviation, was in the range of 0.25 - 2.77%, and the recovery of the method was in the range of 92 - 105%. The UPLC-photodiode array detection-based fingerprint analysis and quantitative methods reported here could be used for routine quality control of N. jatamansi . Georg Thieme Verlag KG Stuttgart · New York.

  2. A Quality Approach to Writing Assessment.

    ERIC Educational Resources Information Center

    Andrade, Joanne; Ryley, Helen

    1992-01-01

    A Colorado elementary school began its Total Quality Management work about a year ago after several staff members participated in an IBM Leadership Training Program addressing applications of Deming's theories. The school's new writing assessment has increased collegiality and cross-grade collaboration. (MLH)

  3. Methods for microbiological quality assessment in drinking water: a comparative study.

    PubMed

    Helmi, K; Barthod, F; Méheut, G; Henry, A; Poty, F; Laurent, F; Charni-Ben-Tabassi, N

    2015-03-01

    The present study aimed to compare several methods for quantifying and discriminating between the different physiological states of a bacterial population present in drinking water. Flow cytometry (FCM), solid-phase cytometry (SPC), epifluorescence microscopy (MSP) and culture method performances were assessed by comparing the results obtained for different water samples. These samples, including chlorinated and non-chlorinated water, were collected in a drinking water treatment plant. Total bacteria were quantified by using SYBR Green II (for FCM) and 4',6'-diamino-2-phenylindole (DAPI) (for MSP), viable and non-viable bacteria were distinguished by using SYBR Green II and propidium iodide dual staining (for FCM), and active cells were distinguished by using CTC (for MSP) and Chemchrome V6 (for FCM and SPC). In our conditions, counts using microscopy and FCM were significantly correlated regarding total bacteria and active cells. Conversely, counts were not significantly similar using solid-phase and FCM for active bacteria. Moreover, the R2A medium showed that bacterial culturability could be recovered after chlorination. This study highlights that FCM appears to be a useful and powerful technique for drinking water production monitoring.

  4. Reduced-Reference Quality Assessment Based on the Entropy of DWT Coefficients of Locally Weighted Gradient Magnitudes.

    PubMed

    Golestaneh, S Alireza; Karam, Lina

    2016-08-24

    Perceptual image quality assessment (IQA) attempts to use computational models to estimate the image quality in accordance with subjective evaluations. Reduced-reference (RR) image quality assessment (IQA) methods make use of partial information or features extracted from the reference image for estimating the quality of distorted images. Finding a balance between the number of RR features and accuracy of the estimated image quality is essential and important in IQA. In this paper we propose a training-free low-cost RRIQA method that requires a very small number of RR features (6 RR features). The proposed RRIQA algorithm is based on the discrete wavelet transform (DWT) of locally weighted gradient magnitudes.We apply human visual system's contrast sensitivity and neighborhood gradient information to weight the gradient magnitudes in a locally adaptive manner. The RR features are computed by measuring the entropy of each DWT subband, for each scale, and pooling the subband entropies along all orientations, resulting in L RR features (one average entropy per scale) for an L-level DWT. Extensive experiments performed on seven large-scale benchmark databases demonstrate that the proposed RRIQA method delivers highly competitive performance as compared to the state-of-the-art RRIQA models as well as full reference ones for both natural and texture images. The MATLAB source code of REDLOG and the evaluation results are publicly available online at https://http://lab.engineering.asu.edu/ivulab/software/redlog/.

  5. Numerical methods for assessing water quality in lakes and reservoirs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mahamah, D.S.

    1984-01-01

    Water quality models are used as tools for predicting both short-term and long-term trends in water quality. They are generally classified into two groups based on the degree of empiricism. The two groups consists of the purely empirical types known as black-box models and the theoretical types called ecosystem models. This dissertation deals with both types of water quality models. The first part deals with empirical phosphorus models. The theory behind this class of models is discussed, leading to the development of an empirical phosphorus model using data from 79 western US lakes. A new approach to trophic state classificationmore » is introduced. The data used for the model was obtained from the Environmental Protection Agency National Eutrophication Study (EPA-NES) of western US lakes. The second portion of the dissertation discusses the development of an ecosystem model for culturally eutrophic Liberty Lake situated in eastern Washington State. The model is capable of simulating chlorophyll-a, phosphorus, and nitrogen levels in the lake on a weekly basis. For computing sediment release rates of phosphorus and nitrogen, equations based on laboratory bench-top studies using sediment samples from Liberty Lake are used. The model is used to simulate certain hypothetical nutrient control techniques such as phosphorus flushing, precipitation, and diversion.« less

  6. A method for evaluating treatment quality using in vivo EPID dosimetry and statistical process control in radiation therapy.

    PubMed

    Fuangrod, Todsaporn; Greer, Peter B; Simpson, John; Zwan, Benjamin J; Middleton, Richard H

    2017-03-13

    Purpose Due to increasing complexity, modern radiotherapy techniques require comprehensive quality assurance (QA) programmes, that to date generally focus on the pre-treatment stage. The purpose of this paper is to provide a method for an individual patient treatment QA evaluation and identification of a "quality gap" for continuous quality improvement. Design/methodology/approach A statistical process control (SPC) was applied to evaluate treatment delivery using in vivo electronic portal imaging device (EPID) dosimetry. A moving range control chart was constructed to monitor the individual patient treatment performance based on a control limit generated from initial data of 90 intensity-modulated radiotherapy (IMRT) and ten volumetric-modulated arc therapy (VMAT) patient deliveries. A process capability index was used to evaluate the continuing treatment quality based on three quality classes: treatment type-specific, treatment linac-specific, and body site-specific. Findings The determined control limits were 62.5 and 70.0 per cent of the χ pass-rate for IMRT and VMAT deliveries, respectively. In total, 14 patients were selected for a pilot study the results of which showed that about 1 per cent of all treatments contained errors relating to unexpected anatomical changes between treatment fractions. Both rectum and pelvis cancer treatments demonstrated process capability indices were less than 1, indicating the potential for quality improvement and hence may benefit from further assessment. Research limitations/implications The study relied on the application of in vivo EPID dosimetry for patients treated at the specific centre. Sampling patients for generating the control limits were limited to 100 patients. Whilst the quantitative results are specific to the clinical techniques and equipment used, the described method is generally applicable to IMRT and VMAT treatment QA. Whilst more work is required to determine the level of clinical significance, the

  7. Assessing the Quality of PhD Dissertations. A Survey of External Committee Members

    ERIC Educational Resources Information Center

    Kyvik, Svein; Thune, Taran

    2015-01-01

    This article reports on a study of the quality assessment of doctoral dissertations, and asks whether examiner characteristics influence assessment of research quality in PhD dissertations. Utilising a multi-dimensional concept of quality of PhD dissertations, we look at differences in assessment of research quality, and particularly test whether…

  8. Educational Quality, Outcomes Assessment, and Policy Change: The Virginia Example

    ERIC Educational Resources Information Center

    Culver, Steve

    2010-01-01

    The higher education system in the Commonwealth of Virginia in the United States provides a case model for how discussions regarding educational quality and assessment of that quality have affected institutions' policy decisions and implementation. Using Levin's (1998) policy analysis framework, this essay explores how assessment of student…

  9. Indoor Air Quality Building Education and Assessment Model Forms

    EPA Pesticide Factsheets

    The Indoor Air Quality Building Education and Assessment Model (I-BEAM) is a guidance tool designed for use by building professionals and others interested in indoor air quality in commercial buildings.

  10. Analytical performance specifications for external quality assessment - definitions and descriptions.

    PubMed

    Jones, Graham R D; Albarede, Stephanie; Kesseler, Dagmar; MacKenzie, Finlay; Mammen, Joy; Pedersen, Morten; Stavelin, Anne; Thelen, Marc; Thomas, Annette; Twomey, Patrick J; Ventura, Emma; Panteghini, Mauro

    2017-06-27

    External Quality Assurance (EQA) is vital to ensure acceptable analytical quality in medical laboratories. A key component of an EQA scheme is an analytical performance specification (APS) for each measurand that a laboratory can use to assess the extent of deviation of the obtained results from the target value. A consensus conference held in Milan in 2014 has proposed three models to set APS and these can be applied to setting APS for EQA. A goal arising from this conference is the harmonisation of EQA APS between different schemes to deliver consistent quality messages to laboratories irrespective of location and the choice of EQA provider. At this time there are wide differences in the APS used in different EQA schemes for the same measurands. Contributing factors to this variation are that the APS in different schemes are established using different criteria, applied to different types of data (e.g. single data points, multiple data points), used for different goals (e.g. improvement of analytical quality; licensing), and with the aim of eliciting different responses from participants. This paper provides recommendations from the European Federation of Laboratory Medicine (EFLM) Task and Finish Group on Performance Specifications for External Quality Assurance Schemes (TFG-APSEQA) and on clear terminology for EQA APS. The recommended terminology covers six elements required to understand APS: 1) a statement on the EQA material matrix and its commutability; 2) the method used to assign the target value; 3) the data set to which APS are applied; 4) the applicable analytical property being assessed (i.e. total error, bias, imprecision, uncertainty); 5) the rationale for the selection of the APS; and 6) the type of the Milan model(s) used to set the APS. The terminology is required for EQA participants and other interested parties to understand the meaning of meeting or not meeting APS.

  11. Improved statistical assessment of a long-term groundwater-quality dataset with a non-parametric permutation method

    NASA Astrophysics Data System (ADS)

    Thomas, M. A.

    2016-12-01

    The Waste Isolation Pilot Plant (WIPP) is the only deep geological repository for transuranic waste in the United States. As the Science Advisor for the WIPP, Sandia National Laboratories annually evaluates site data against trigger values (TVs), metrics whose violation is indicative of conditions that may impact long-term repository performance. This study focuses on a groundwater-quality dataset used to redesign a TV for the Culebra Dolomite Member (Culebra) of the Permian-age Rustler Formation. Prior to this study, a TV violation occurred if the concentration of a major ion fell outside a range defined as the mean +/- two standard deviations. The ranges were thought to denote conditions that 95% of future values would fall within. Groundwater-quality data used in evaluating compliance, however, are rarely normally distributed. To create a more robust Culebra groundwater-quality TV, this study employed the randomization test, a non-parametric permutation method. Recent groundwater compositions considered TV violations under the original ion concentration ranges are now interpreted as false positives in light of the insignificant p-values calculated with the randomization test. This work highlights that the normality assumption can weaken as the size of a groundwater-quality dataset grows over time. Non-parametric permutation methods are an attractive option because no assumption about the statistical distribution is required and calculating all combinations of the data is an increasingly tractable problem with modern workstations. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000. This research is funded by WIPP programs administered by the Office of Environmental Management (EM) of the U.S. Department of Energy. SAND2016-7306A

  12. Microfluidic Method of Pig Oocyte Quality Assessment in relation to Different Follicular Size Based on Lab-on-Chip Technology

    PubMed Central

    Walczak, Rafał; Antosik, Paweł; Sniadek, Patrycja; Piotrowska, Hanna; Bukowska, Dorota; Dziuban, Jan; Nowicki, Michał; Jaśkowski, Jędrzej M.; Brüssow, Klaus-Peter

    2014-01-01

    Since microfollicular environment and the size of the follicle are important markers influencing oocyte quality, the aim of this study is to present the spectral characterization of oocytes isolated from follicles of various sizes using lab-on-chip (LOC) technology and to demonstrate how follicle size may affect oocyte quality. Porcine oocytes (each, n = 100) recovered from follicles of different sizes, for example, from large (>5 mm), medium (3–5 mm), and small (<3 mm), were analyzed after preceding in vitro maturation (IVM). The LOC analysis was performed using a silicon-glass sandwich with two glass optical fibers positioned “face-to-face.” Oocytes collected from follicles of different size classes revealed specific and distinguishable spectral characteristics. The absorbance spectra (microspectrometric specificity) for oocytes isolated from large, medium, and small follicles differ significantly (P < 0.05) and the absorbance wavelengths were between 626 and 628 nm, between 618 and 620 nm, and less than 618 nm, respectively. The present study offers a parametric and objective method of porcine oocyte assessment. However, up to now this study has been used to evidence spectral markers associated with follicular size in pigs, only. Further investigations with functional-biological assays and comparing LOC analyses with fertilization and pregnancy success and the outcome of healthy offspring must be performed. PMID:25548771

  13. Endorsing good quality assurance practices in molecular pathology: risks and recommendations for diagnostic laboratories and external quality assessment providers.

    PubMed

    Tembuyser, Lien; Dequeker, Elisabeth M C

    2016-01-01

    Quality assurance is an indispensable element in a molecular diagnostic laboratory. The ultimate goal is to warrant patient safety. Several risks that can compromise high quality procedures are at stake, from sample collection to the test performed by the laboratory, the reporting of test results to clinicians, and the organization of effective external quality assessment schemes. Quality assurance should therefore be safeguarded at each level and should imply a holistic multidisciplinary approach. This review aims to provide an overview of good quality assurance practices and discusses certain risks and recommendations to promote and improve quality assurance for both diagnostic laboratories and for external quality assessment providers. The number of molecular targets is continuously rising, and new technologies are evolving. As this poses challenges for clinical implementation and increases the demand for external quality assessment, the formation of an international association for improving quality assurance in molecular pathology is called for.

  14. Quality assessment of groundwater from the south-eastern Arabian Peninsula.

    PubMed

    Zhang, H W; Sun, Y Q; Li, Y; Zhou, X D; Tang, X Z; Yi, P; Murad, A; Hussein, S; Alshamsi, D; Aldahan, A; Yu, Z B; Chen, X G; Mugwaneza, V D P

    2017-08-01

    Assessment of groundwater quality plays a significant role in the utilization of the scarce water resources globally and especially in arid regions. The increasing abstraction together with man-made contamination and seawater intrusion have strongly affected groundwater quality in the Arabia Peninsula, exemplified by the investigation given here from the United Arab Emirates, where the groundwater is seldom reviewed and assessed. In the aim of assessing current groundwater quality, we here present a comparison of chemical data linked to aquifers types. The results reveal that most of the investigated groundwater is not suitable for drinking, household, and agricultural purposes following the WHO permissible limits. Aquifer composition and climate have vital control on the water quality, with the carbonate aquifers contain the least potable water compared to the ophiolites and Quaternary clastics. Seawater intrusion along coastal regions has deteriorated the water quality and the phenomenon may become more intensive with future warming climate and rising sea level.

  15. New Hampshire Quality Rating System: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of New Hampshire's Quality Rating System prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4)…

  16. Assessment of the Quality Management Models in Higher Education

    ERIC Educational Resources Information Center

    Basar, Gulsun; Altinay, Zehra; Dagli, Gokmen; Altinay, Fahriye

    2016-01-01

    This study involves the assessment of the quality management models in Higher Education by explaining the importance of quality in higher education and by examining the higher education quality assurance system practices in other countries. The qualitative study was carried out with the members of the Higher Education Planning, Evaluation,…

  17. The Emergence of Quality Assessment in Brazilian Basic Education

    ERIC Educational Resources Information Center

    Kauko, Jaakko; Centeno, Vera Gorodski; Candido, Helena; Shiroma, Eneida; Klutas, Anni

    2016-01-01

    The focus in this article is on Brazilian education policy, specifically quality assurance and evaluation. The starting point is that quality, measured by means of large-scale assessments, is one of the key discursive justifications for educational change. The article addresses the questions of how quality evaluation became a significant feature…

  18. Assessment and the Quality of Educational Programmes: What Constitutes Evidence?

    ERIC Educational Resources Information Center

    Shay, Sueellen; Jawitz, Jeff

    2005-01-01

    In a climate of growing accountability for Higher Education, there is an increased demand on assessment to play an evaluative role. National, professional and institutional quality assurance systems expect that the assessment of student performance can be used to evaluate the quality of teachers, learners, programmes and even institutions for the…

  19. Quality Control Guidelines for SAM Chemical Methods

    EPA Pesticide Factsheets

    Learn more about quality control guidelines and recommendations for the analysis of samples using the chemistry methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  20. Quality Control Guidelines for SAM Radiochemical Methods

    EPA Pesticide Factsheets

    Learn more about quality control guidelines and recommendations for the analysis of samples using the radiochemistry methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  1. Quality Control Guidelines for SAM Biotoxin Methods

    EPA Pesticide Factsheets

    Learn more about quality control guidelines and recommendations for the analysis of samples using the pathogen methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  2. Quality Control Guidelines for SAM Pathogen Methods

    EPA Pesticide Factsheets

    Learn more about quality control guidelines and recommendations for the analysis of samples using the biotoxin methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  3. Objective speech quality assessment and the RPE-LTP coding algorithm in different noise and language conditions.

    PubMed

    Hansen, J H; Nandkumar, S

    1995-01-01

    The formulation of reliable signal processing algorithms for speech coding and synthesis require the selection of a prior criterion of performance. Though coding efficiency (bits/second) or computational requirements can be used, a final performance measure must always include speech quality. In this paper, three objective speech quality measures are considered with respect to quality assessment for American English, noisy American English, and noise-free versions of seven languages. The purpose is to determine whether objective quality measures can be used to quantify changes in quality for a given voice coding method, with a known subjective performance level, as background noise or language conditions are changed. The speech coding algorithm chosen is regular-pulse excitation with long-term prediction (RPE-LTP), which has been chosen as the standard voice compression algorithm for the European Digital Mobile Radio system. Three areas are considered for objective quality assessment which include: (i) vocoder performance for American English in a noise-free environment, (ii) speech quality variation for three additive background noise sources, and (iii) noise-free performance for seven languages which include English, Japanese, Finnish, German, Hindi, Spanish, and French. It is suggested that although existing objective quality measures will never replace subjective testing, they can be a useful means of assessing changes in performance, identifying areas for improvement in algorithm design, and augmenting subjective quality tests for voice coding/compression algorithms in noise-free, noisy, and/or non-English applications.

  4. Assessing Patterns of Alcohol Taxes Produced by Various Types of Excise Tax Methods--A Simulation Study.

    PubMed

    Sornpaisarn, Bundit; Kaewmungkun, Chuthaporn; Rehm, Jürgen

    2015-11-01

    To examine patterns of tax burdens produced by specific, ad valorem, and various types of combination taxations. One hundred unique hypothetical alcoholic beverages were mathematically simulated based on the amount of ethanol and perceived-qualities contained. Second, beverages were assigned values of various costs and tax rates, and third, patterns of tax burden were assessed per unit of ethanol produced by each type of tax method. Different tax methods produced different tax burdens per unit of ethanol for different alcoholic beverages. The tax burden produced by the ad valorem tax resulted in a lower tax burden for low perceived-quality alcoholic beverages. The specific tax method showed the same tax burden for both low and high perceived-quality alcoholic beverages. However, high perceived-quality beverages benefited from a lower tax burden per beverage price. Lastly, the combination tax method resulted in a lower tax burden for medium perceived-quality alcoholic beverages. Under the oligopoly market, ad valorem taxation encourages consumption of low perceived-quality beverages; specific taxation encourages consumption of high perceived-quality beverages; and combination tax methods encourage consumption of medium perceived-quality beverages. © The Author 2015. Medical Council on Alcohol and Oxford University Press. All rights reserved.

  5. The Need for Standardized Assessment of Muscle Quality in Skeletal Muscle Function Deficit and Other Aging-Related Muscle Dysfunctions: A Symposium Report.

    PubMed

    Correa-de-Araujo, Rosaly; Harris-Love, Michael O; Miljkovic, Iva; Fragala, Maren S; Anthony, Brian W; Manini, Todd M

    2017-01-01

    A growing body of scientific literature suggests that not only changes in skeletal muscle mass, but also other factors underpinning muscle quality, play a role in the decline in skeletal muscle function and impaired mobility associated with aging. A symposium on muscle quality and the need for standardized assessment was held on April 28, 2016 at the International Conference on Frailty and Sarcopenia Research in Philadelphia, Pennsylvania. The purpose of this symposium was to provide a venue for basic science and clinical researchers and expert clinicians to discuss muscle quality in the context of skeletal muscle function deficit and other aging-related muscle dysfunctions. The present article provides an expanded introduction concerning the emerging definitions of muscle quality and a potential framework for scientific inquiry within the field. Changes in muscle tissue composition, based on excessive levels of inter- and intra-muscular adipose tissue and intramyocellular lipids, have been found to adversely impact metabolism and peak force generation. However, methods to easily and rapidly assess muscle tissue composition in multiple clinical settings and with minimal patient burden are needed. Diagnostic ultrasound and other assessment methods continue to be developed for characterizing muscle pathology, and enhanced sonography using sensors to provide user feedback and improve reliability is currently the subject of ongoing investigation and development. In addition, measures of relative muscle force such as specific force or grip strength adjusted for body size have been proposed as methods to assess changes in muscle quality. Furthermore, performance-based assessments of muscle power via timed tests of function and body size estimates, are associated with lower extremity muscle strength may be responsive to age-related changes in muscle quality. Future aims include reaching consensus on the definition and standardized assessments of muscle quality, and

  6. Evaluation of ride quality prediction methods for helicopter interior noise and vibration environments

    NASA Technical Reports Server (NTRS)

    Leatherwood, J. D.; Clevenson, S. A.; Hollenbaugh, D. D.

    1984-01-01

    The results of a simulator study conducted to compare and validate various ride quality prediction methods for use in assessing passenger/crew ride comfort within helicopters are presented. Included are results quantifying 35 helicopter pilots discomfort responses to helicopter interior noise and vibration typical of routine flights, assessment of various ride quality metrics including the NASA ride comfort model, and examination of possible criteria approaches. Results of the study indicated that crew discomfort results from a complex interaction between vibration and interior noise. Overall measures such as weighted or unweighted root-mean-square acceleration level and A-weighted noise level were not good predictors of discomfort. Accurate prediction required a metric incorporating the interactive effects of both noise and vibration. The best metric for predicting crew comfort to the combined noise and vibration environment was the NASA discomfort index.

  7. Improving the quality of discrete-choice experiments in health: how can we assess validity and reliability?

    PubMed

    Janssen, Ellen M; Marshall, Deborah A; Hauber, A Brett; Bridges, John F P

    2017-12-01

    The recent endorsement of discrete-choice experiments (DCEs) and other stated-preference methods by regulatory and health technology assessment (HTA) agencies has placed a greater focus on demonstrating the validity and reliability of preference results. Areas covered: We present a practical overview of tests of validity and reliability that have been applied in the health DCE literature and explore other study qualities of DCEs. From the published literature, we identify a variety of methods to assess the validity and reliability of DCEs. We conceptualize these methods to create a conceptual model with four domains: measurement validity, measurement reliability, choice validity, and choice reliability. Each domain consists of three categories that can be assessed using one to four procedures (for a total of 24 tests). We present how these tests have been applied in the literature and direct readers to applications of these tests in the health DCE literature. Based on a stakeholder engagement exercise, we consider the importance of study characteristics beyond traditional concepts of validity and reliability. Expert commentary: We discuss study design considerations to assess the validity and reliability of a DCE, consider limitations to the current application of tests, and discuss future work to consider the quality of DCEs in healthcare.

  8. Ohio Step Up to Quality: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Ohio's Step Up to Quality prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for Family…

  9. Identification and Assessment of Potential Water Quality Impact Factors for Drinking-Water Reservoirs

    PubMed Central

    Gu, Qing; Deng, Jinsong; Wang, Ke; Lin, Yi; Li, Jun; Gan, Muye; Ma, Ligang; Hong, Yang

    2014-01-01

    Various reservoirs have been serving as the most important drinking water sources in Zhejiang Province, China, due to the uneven distribution of precipitation and severe river pollution. Unfortunately, rapid urbanization and industrialization have been continuously challenging the water quality of the drinking-water reservoirs. The identification and assessment of potential impacts is indispensable in water resource management and protection. This study investigates the drinking water reservoirs in Zhejiang Province to better understand the potential impact on water quality. Altogether seventy-three typical drinking reservoirs in Zhejiang Province encompassing various water storage levels were selected and evaluated. Using fifty-two reservoirs as training samples, the classification and regression tree (CART) method and sixteen comprehensive variables, including six sub-sets (land use, population, socio-economy, geographical features, inherent characteristics, and climate), were adopted to establish a decision-making model for identifying and assessing their potential impacts on drinking-water quality. The water quality class of the remaining twenty-one reservoirs was then predicted and tested based on the decision-making model, resulting in a water quality class attribution accuracy of 81.0%. Based on the decision rules and quantitative importance of the independent variables, industrial emissions was identified as the most important factor influencing the water quality of reservoirs; land use and human habitation also had a substantial impact on water quality. The results of this study provide insights into the factors impacting the water quality of reservoirs as well as basic information for protecting reservoir water resources. PMID:24919129

  10. dipIQ: Blind Image Quality Assessment by Learning-to-Rank Discriminable Image Pairs.

    PubMed

    Ma, Kede; Liu, Wentao; Liu, Tongliang; Wang, Zhou; Tao, Dacheng

    2017-05-26

    Objective assessment of image quality is fundamentally important in many image processing tasks. In this work, we focus on learning blind image quality assessment (BIQA) models which predict the quality of a digital image with no access to its original pristine-quality counterpart as reference. One of the biggest challenges in learning BIQA models is the conflict between the gigantic image space (which is in the dimension of the number of image pixels) and the extremely limited reliable ground truth data for training. Such data are typically collected via subjective testing, which is cumbersome, slow, and expensive. Here we first show that a vast amount of reliable training data in the form of quality-discriminable image pairs (DIP) can be obtained automatically at low cost by exploiting largescale databases with diverse image content. We then learn an opinion-unaware BIQA (OU-BIQA, meaning that no subjective opinions are used for training) model using RankNet, a pairwise learning-to-rank (L2R) algorithm, from millions of DIPs, each associated with a perceptual uncertainty level, leading to a DIP inferred quality (dipIQ) index. Extensive experiments on four benchmark IQA databases demonstrate that dipIQ outperforms state-of-the-art OU-BIQA models. The robustness of dipIQ is also significantly improved as confirmed by the group MAximum Differentiation (gMAD) competition method. Furthermore, we extend the proposed framework by learning models with ListNet (a listwise L2R algorithm) on quality-discriminable image lists (DIL). The resulting DIL Inferred Quality (dilIQ) index achieves an additional performance gain.

  11. Algorithm for automatic forced spirometry quality assessment: technological developments.

    PubMed

    Melia, Umberto; Burgos, Felip; Vallverdú, Montserrat; Velickovski, Filip; Lluch-Ariet, Magí; Roca, Josep; Caminal, Pere

    2014-01-01

    We hypothesized that the implementation of automatic real-time assessment of quality of forced spirometry (FS) may significantly enhance the potential for extensive deployment of a FS program in the community. Recent studies have demonstrated that the application of quality criteria defined by the ATS/ERS (American Thoracic Society/European Respiratory Society) in commercially available equipment with automatic quality assessment can be markedly improved. To this end, an algorithm for assessing quality of FS automatically was reported. The current research describes the mathematical developments of the algorithm. An innovative analysis of the shape of the spirometric curve, adding 23 new metrics to the traditional 4 recommended by ATS/ERS, was done. The algorithm was created through a two-step iterative process including: (1) an initial version using the standard FS curves recommended by the ATS; and, (2) a refined version using curves from patients. In each of these steps the results were assessed against one expert's opinion. Finally, an independent set of FS curves from 291 patients was used for validation purposes. The novel mathematical approach to characterize the FS curves led to appropriate FS classification with high specificity (95%) and sensitivity (96%). The results constitute the basis for a successful transfer of FS testing to non-specialized professionals in the community.

  12. Untrained consumer assessment of the eating quality of beef: 1. A single composite score can predict beef quality grades.

    PubMed

    Bonny, S P F; Hocquette, J-F; Pethick, D W; Legrand, I; Wierzbicki, J; Allen, P; Farmer, L J; Polkinghorne, R J; Gardner, G E

    2017-08-01

    Quantifying consumer responses to beef across a broad range of demographics, nationalities and cooking methods is vitally important for any system evaluating beef eating quality. On the basis of previous work, it was expected that consumer scores would be highly accurate in determining quality grades for beef, thereby providing evidence that such a technique could be used to form the basis of and eating quality grading system for beef. Following the Australian MSA (Meat Standards Australia) testing protocols, over 19 000 consumers from Northern Ireland, Poland, Ireland, France and Australia tasted cooked beef samples, then allocated them to a quality grade; unsatisfactory, good-every-day, better-than-every-day and premium. The consumers also scored beef samples for tenderness, juiciness, flavour-liking and overall-liking. The beef was sourced from all countries involved in the study and cooked by four different cooking methods and to three different degrees of doneness, with each experimental group in the study consisting of a single cooking doneness within a cooking method for each country. For each experimental group, and for the data set as a whole, a linear discriminant function was calculated, using the four sensory scores which were used to predict the quality grade. This process was repeated using two conglomerate scores which are derived from weighting and combining the consumer sensory scores for tenderness, juiciness, flavour-liking and overall-liking, the original meat quality 4 score (oMQ4) (0.4, 0.1, 0.2, 0.3) and current meat quality 4 score (cMQ4) (0.3, 0.1, 0.3, 0.3). From the results of these analyses, the optimal weightings of the sensory scores to generate an 'ideal meat quality 4 score (MQ4)' for each country were calculated, and the MQ4 values that reflected the boundaries between the four quality grades were determined. The oMQ4 weightings were far more accurate in categorising European meat samples than the cMQ4 weightings, highlighting that

  13. 1995 mask industry quality assessment

    NASA Astrophysics Data System (ADS)

    Bishop, Chris; Strott, Al

    1995-12-01

    The third annual mask industry assessment will again survey various industry companies for key performance measurements in the areas of quality and delivery. This year's assessment is enhanced to include the area of safety and further breakdown of the data into 5-inch vs. 6- inch. The data compiled includes shipments, customer return rate, customer return reason, performance to schedule, plate survival yield, and throughput time (TPT) from 1988 through Q2, 1995. Contributor identities remain protected by utilizing Arthur Andersen & Company to ensure participant confidentiality. Participation in the past included representation of over 75% of the total merchant and captive mask volume in the United States. This year's assessment is expected to result in expanded participation by again inviting all mask suppliers domestically to participate as well as an impact from inviting international suppliers to participate.

  14. The quality of reporting in cluster randomised crossover trials: proposal for reporting items and an assessment of reporting quality.

    PubMed

    Arnup, Sarah J; Forbes, Andrew B; Kahan, Brennan C; Morgan, Katy E; McKenzie, Joanne E

    2016-12-06

    The cluster randomised crossover (CRXO) design is gaining popularity in trial settings where individual randomisation or parallel group cluster randomisation is not feasible or practical. Our aim is to stimulate discussion on the content of a reporting guideline for CRXO trials and to assess the reporting quality of published CRXO trials. We undertook a systematic review of CRXO trials. Searches of MEDLINE, EMBASE, and CINAHL Plus as well as citation searches of CRXO methodological articles were conducted to December 2014. Reporting quality was assessed against both modified items from 2010 CONSORT and 2012 cluster trials extension and other proposed quality measures. Of the 3425 records identified through database searching, 83 trials met the inclusion criteria. Trials were infrequently identified as "cluster randomis(z)ed crossover" in title (n = 7, 8%) or abstract (n = 21, 25%), and a rationale for the design was infrequently provided (n = 20, 24%). Design parameters such as the number of clusters and number of periods were well reported. Discussion of carryover took place in only 17 trials (20%). Sample size methods were only reported in 58% (n = 48) of trials. A range of approaches were used to report baseline characteristics. The analysis method was not adequately reported in 23% (n = 19) of trials. The observed within-cluster within-period intracluster correlation and within-cluster between-period intracluster correlation for the primary outcome data were not reported in any trial. The potential for selection, performance, and detection bias could be evaluated in 30%, 81%, and 70% of trials, respectively. There is a clear need to improve the quality of reporting in CRXO trials. Given the unique features of a CRXO trial, it is important to develop a CONSORT extension. Consensus amongst trialists on the content of such a guideline is essential.

  15. Identifying Items to Assess Methodological Quality in Physical Therapy Trials: A Factor Analysis

    PubMed Central

    Cummings, Greta G.; Fuentes, Jorge; Saltaji, Humam; Ha, Christine; Chisholm, Annabritt; Pasichnyk, Dion; Rogers, Todd

    2014-01-01

    Background Numerous tools and individual items have been proposed to assess the methodological quality of randomized controlled trials (RCTs). The frequency of use of these items varies according to health area, which suggests a lack of agreement regarding their relevance to trial quality or risk of bias. Objective The objectives of this study were: (1) to identify the underlying component structure of items and (2) to determine relevant items to evaluate the quality and risk of bias of trials in physical therapy by using an exploratory factor analysis (EFA). Design A methodological research design was used, and an EFA was performed. Methods Randomized controlled trials used for this study were randomly selected from searches of the Cochrane Database of Systematic Reviews. Two reviewers used 45 items gathered from 7 different quality tools to assess the methodological quality of the RCTs. An exploratory factor analysis was conducted using the principal axis factoring (PAF) method followed by varimax rotation. Results Principal axis factoring identified 34 items loaded on 9 common factors: (1) selection bias; (2) performance and detection bias; (3) eligibility, intervention details, and description of outcome measures; (4) psychometric properties of the main outcome; (5) contamination and adherence to treatment; (6) attrition bias; (7) data analysis; (8) sample size; and (9) control and placebo adequacy. Limitation Because of the exploratory nature of the results, a confirmatory factor analysis is needed to validate this model. Conclusions To the authors' knowledge, this is the first factor analysis to explore the underlying component items used to evaluate the methodological quality or risk of bias of RCTs in physical therapy. The items and factors represent a starting point for evaluating the methodological quality and risk of bias in physical therapy trials. Empirical evidence of the association among these items with treatment effects and a confirmatory factor

  16. National Assessment of Data Quality and Associated Systems-Level Factors in Malawi

    PubMed Central

    O'Hagan, Richael; Marx, Melissa A; Finnegan, Karen E; Naphini, Patrick; Ng'ambi, Kumbukani; Laija, Kingsley; Wilson, Emily; Park, Lois; Wachepa, Sautso; Smith, Joseph; Gombwa, Lewis; Misomali, Amos; Mleme, Tiope; Yosefe, Simeon

    2017-01-01

    ABSTRACT Background: Routine health data can guide health systems improvements, but poor quality of these data hinders use. To address concerns about data quality in Malawi, the Ministry of Health and National Statistical Office conducted a data quality assessment (DQA) in July 2016 to identify systems-level factors that could be improved. Methods: We used 2-stage stratified random sampling methods to select health centers and hospitals under Ministry of Health auspices, included those managed by faith-based entities, for this DQA. Dispensaries, village clinics, police and military facilities, tertiary-level hospitals, and private facilities were excluded. We reviewed client registers and monthly reports to verify availability, completeness, and accuracy of data in 4 service areas: antenatal care (ANC), family planning, HIV testing and counseling, and acute respiratory infection (ARI). We also conducted interviews with facility and district personnel to assess health management information system (HMIS) functioning and systems-level factors that may be associated with data quality. We compared systems and quality factors by facility characteristics using 2-sample t tests with Welch's approximation, and calculated verification ratios comparing total entries in registers to totals from summarized reports. Results: We selected 16 hospitals (of 113 total in Malawi), 90 health centers (of 466), and 16 district health offices (of 28) in 16 of Malawi's 28 districts. Nearly all registers were available and complete in health centers and district hospitals, but data quality varied across service areas; median verification ratios comparing register and report totals at health centers ranged from 0.78 (interquartile range [IQR]: 0.25, 1.07) for ARI and 0.99 (IQR: 0.82, 1.36) for family planning to 1.00 (IQR: 0.96, 1.00) for HIV testing and counseling and 1.00 (IQR: 0.80, 1.23) for ANC. More than half (60%) of facilities reported receiving a documented supervisory visit for

  17. Surface-water-quality assessment of the Kentucky River Basin, Kentucky; fixed-station network and selected water-quality data, April 1987 through August 1991

    USGS Publications Warehouse

    Griffin, M.S.; Martin, G.R.; White, K.D.

    1994-01-01

    This report describes selected data-collection activities and the associated data collected during the Kentucky River Basin pilot study of the U.S. Geological Survey's National Water-Quality Assessment Program. The data are intended to provide a nationally consistent description and improved understanding of current water quality in the basin. The data were collected at seven fixed stations that represent stream cross sections where constituent transport and water-quality trends can be evaluated. The report includes descriptions of (1) the basin; (2) the design of the fixed-station network; (3) the fixed-station sites; (4) the physical and chemical measurements; (5) the methods of sample collection, processing, and analysis; and (6) the quality-assurance and quality-control procedures. Water-quality data collected at the fixed stations during routine periodic sampling and supplemental high-flow sampling from April 1987 to August 1991 are presented.

  18. Assessment of the Quality of Digital Terrain Model Produced from Unmanned Aerial System Imagery

    NASA Astrophysics Data System (ADS)

    Kosmatin Fras, M.; Kerin, A.; Mesarič, M.; Peterman, V.; Grigillo, D.

    2016-06-01

    Production of digital terrain model (DTM) is one of the most usual tasks when processing photogrammetric point cloud generated from Unmanned Aerial System (UAS) imagery. The quality of the DTM produced in this way depends on different factors: the quality of imagery, image orientation and camera calibration, point cloud filtering, interpolation methods etc. However, the assessment of the real quality of DTM is very important for its further use and applications. In this paper we first describe the main steps of UAS imagery acquisition and processing based on practical test field survey and data. The main focus of this paper is to present the approach to DTM quality assessment and to give a practical example on the test field data. For data processing and DTM quality assessment presented in this paper mainly the in-house developed computer programs have been used. The quality of DTM comprises its accuracy, density, and completeness. Different accuracy measures like RMSE, median, normalized median absolute deviation and their confidence interval, quantiles are computed. The completeness of the DTM is very often overlooked quality parameter, but when DTM is produced from the point cloud this should not be neglected as some areas might be very sparsely covered by points. The original density is presented with density plot or map. The completeness is presented by the map of point density and the map of distances between grid points and terrain points. The results in the test area show great potential of the DTM produced from UAS imagery, in the sense of detailed representation of the terrain as well as good height accuracy.

  19. Methods for assessing geodiversity

    NASA Astrophysics Data System (ADS)

    Zwoliński, Zbigniew; Najwer, Alicja; Giardino, Marco

    2017-04-01

    The accepted systematics of geodiversity assessment methods will be presented in three categories: qualitative, quantitative and qualitative-quantitative. Qualitative methods are usually descriptive methods that are suited to nominal and ordinal data. Quantitative methods use a different set of parameters and indicators to determine the characteristics of geodiversity in the area being researched. Qualitative-quantitative methods are a good combination of the collection of quantitative data (i.e. digital) and cause-effect data (i.e. relational and explanatory). It seems that at the current stage of the development of geodiversity research methods, qualitative-quantitative methods are the most advanced and best assess the geodiversity of the study area. Their particular advantage is the integration of data from different sources and with different substantive content. Among the distinguishing features of the quantitative and qualitative-quantitative methods for assessing geodiversity are their wide use within geographic information systems, both at the stage of data collection and data integration, as well as numerical processing and their presentation. The unresolved problem for these methods, however, is the possibility of their validation. It seems that currently the best method of validation is direct filed confrontation. Looking to the next few years, the development of qualitative-quantitative methods connected with cognitive issues should be expected, oriented towards ontology and the Semantic Web.

  20. Collection methods and quality assessment for Esche-richia coli, water quality, and microbial source tracking data within Tumacácori National Historical Park and the upper Santa Cruz River, Arizona, 2015-16

    USGS Publications Warehouse

    Paretti, Nicholas; Coes, Alissa L.; Kephart, Christopher M.; Mayo, Justine

    2018-03-05

    Tumacácori National Historical Park protects the culturally important Mission, San José de Tumacácori, while also managing a portion of the ecologically diverse riparian corridor of the Santa Cruz River. This report describes the methods and quality assurance procedures used in the collection of water samples for the analysis of Escherichia coli (E. coli), microbial source tracking markers, suspended sediment, water-quality parameters, turbidity, and the data collection for discharge and stage; the process for data review and approval is also described. Finally, this report provides a quantitative assessment of the quality of the E. coli, microbial source tracking, and suspended sediment data.The data-quality assessment revealed that bias attributed to field and laboratory contamination was minimal, with E. coli detections in only 3 out of 33 field blank samples analyzed. Concentrations in the field blanks were several orders of magnitude lower than environmental concentrations. The microbial source tracking (MST) field blank was below the detection limit for all MST markers analyzed. Laboratory blanks for E. coli at the USGS Arizona Water Science Center and laboratory blanks for MST markers at the USGS Ohio Water Microbiology Laboratory were all below the detection limit. Irreplicate data for E. coli and suspended sediment indicated that bias was not introduced to the data by combining samples collected using discrete sampling methods with samples collected using automatic sampling methods.The split and sequential E. coli replicate data showed consistent analytical variability and a single equation was developed to explain the variability of E. coli concentrations. An additional analysis of analytical variability for E. coli indicated analytical variability around 18 percent relative standard deviation and no trend was observed in the concentration during the processing and analysis of multiple split-replicates. Two replicate samples were