Sample records for quality assessment procedure

  1. Quantitative Procedures for the Assessment of Quality in Higher Education Institutions.

    ERIC Educational Resources Information Center

    Moran, Tom; Rowse, Glenwood

    The development of procedures designed to provide quantitative assessments of quality in higher education institutions are reviewed. These procedures employ a systems framework and utilize quantitative data to compare institutions or programs of similar types with one another. Three major elements essential in the development of models focusing on…

  2. A Procedure for High Resolution Satellite Imagery Quality Assessment

    PubMed Central

    Crespi, Mattia; De Vendictis, Laura

    2009-01-01

    Data products generated from High Resolution Satellite Imagery (HRSI) are routinely evaluated during the so-called in-orbit test period, in order to verify if their quality fits the desired features and, if necessary, to obtain the image correction parameters to be used at the ground processing center. Nevertheless, it is often useful to have tools to evaluate image quality also at the final user level. Image quality is defined by some parameters, such as the radiometric resolution and its accuracy, represented by the noise level, and the geometric resolution and sharpness, described by the Modulation Transfer Function (MTF). This paper proposes a procedure to evaluate these image quality parameters; the procedure was implemented in a suitable software and tested on high resolution imagery acquired by the QuickBird, WorldView-1 and Cartosat-1 satellites. PMID:22412312

  3. Towards objective hand hygiene technique assessment: validation of the ultraviolet-dye-based hand-rubbing quality assessment procedure.

    PubMed

    Lehotsky, Á; Szilágyi, L; Bánsághi, S; Szerémy, P; Wéber, G; Haidegger, T

    2017-09-01

    Ultraviolet spectrum markers are widely used for hand hygiene quality assessment, although their microbiological validation has not been established. A microbiology-based assessment of the procedure was conducted. Twenty-five artificial hand models underwent initial full contamination, then disinfection with UV-dyed hand-rub solution, digital imaging under UV-light, microbiological sampling and cultivation, and digital imaging of the cultivated flora were performed. Paired images of each hand model were registered by a software tool, then the UV-marked regions were compared with the pathogen-free sites pixel by pixel. Statistical evaluation revealed that the method indicates correctly disinfected areas with 95.05% sensitivity and 98.01% specificity. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  4. Quality of life assessment in interventional radiology.

    PubMed

    Monsky, Wayne L; Khorsand, Derek; Nolan, Timothy; Douglas, David; Khanna, Pavan

    2014-03-01

    The aim of this review was to describe quality of life (QoL) questionnaires relevant to interventional radiology. Interventional radiologists perform a large number of palliative procedures. The effect of these therapies on QoL is important. This is particularly true for cancer therapies where procedures with marginal survival benefits may result in tremendous QoL benefits. Image-guided minimally invasive procedures should be compared to invasive procedures, with respect to QoL, as part of comparative effectiveness assessment. A large number of questionnaires have been validated for measurement of overall and disease-specific quality of life. Use of applicable QoL assessments can aid in evaluating clinical outcomes and help to further substantiate the need for minimally invasive image-guided procedures. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  5. Procedural training and assessment of competency utilizing simulation.

    PubMed

    Sawyer, Taylor; Gray, Megan M

    2016-11-01

    This review examines the current environment of neonatal procedural learning, describes an updated model of skills training, defines the role of simulation in assessing competency, and discusses potential future directions for simulation-based competency assessment. In order to maximize impact, simulation-based procedural training programs should follow a standardized and evidence-based approach to designing and evaluating educational activities. Simulation can be used to facilitate the evaluation of competency, but must incorporate validated assessment tools to ensure quality and consistency. True competency evaluation cannot be accomplished with simulation alone: competency assessment must also include evaluations of procedural skill during actual clinical care. Future work in this area is needed to measure and track clinically meaningful patient outcomes resulting from simulation-based training, examine the use of simulation to assist physicians undergoing re-entry to practice, and to examine the use of procedural skills simulation as part of a maintenance of competency and life-long learning. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Systematic reviews of surgical procedures in children: quantity, coverage and quality.

    PubMed

    McGee, Richard G; Craig, Jonathan C; Rogerson, Thomas E; Webster, Angela C

    2013-04-01

    Systematic reviews have the potential to map those areas where children are under-represented in surgical research. We aimed to describe and evaluate the quantity, coverage and the quality of conduct and reporting of systematic reviews of surgical procedures in children. We searched four biomedical databases, a systematic review register, reference lists and conducted hand searching to identify relevant reviews. Two reviewers worked independently to critically appraise included studies and abstract data. We assessed reporting quality using the preferred reporting items for systematic reviews and meta-analysis statement and methodological quality using the Assessment of Multiple SysTemAtic Reviews tool. Fifteen systematic reviews were identified, representing 0.01% of all paediatric surgical citations in MEDLINE and Embase. Thirteen of the reviews were Cochrane reviews, and most reviews (12/15) addressed subspecialty interests such as otorhinolaryngology. The median number of included trials per systematic review was four (interquartile range 1 to 9.5), the median number of primary outcomes was 5.5 (interquartile range 3.5 to 7.5). In general, reporting and methodological quality was good although there were several omissions, particularly around completeness of reporting of statistical methods used, and utilisation of quality assessments in analyses. Outcomes were often not clearly defined and descriptions of procedures lacked sufficient detail to determine the similarities and differences among surgical procedures within the contributing trials. Systematic reviews of surgical procedures in children are rarely published. To improve the evidence base and guide research agendas, more systematic reviews should be conducted, using standard guidelines for conduct and reporting. © 2013 The Authors. Journal of Paediatrics and Child Health © 2013 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  7. Quality Issues in Judging Portfolios: Implications for Organizing Teaching Portfolio Assessment Procedures

    ERIC Educational Resources Information Center

    Tigelaar, Dineke E. H.; Dolmans, Diana H. J. M.; Wolfhagen, Ineke H. A. P.; van der Vleuten, Cees P. M.

    2005-01-01

    This article addresses the choice of the most appropriate procedure for the assessment of portfolios used in teacher and lecturer assessment. A characteristic of modern assessment modes, including portfolios, is that the information they provide is often qualitative and derived from different contexts. Unambiguous, objective rating of portfolios…

  8. Quality assurance and gastrointestinal endoscopy: an audit of 500 colonoscopic procedures.

    PubMed

    Denis, Bernard; Weiss, Anne-Marie; Peter, André; Bottlaender, Jacques; Chiappa, Pascale

    2004-12-01

    The aim of this study was to assess the quality of colonoscopic procedures in our endoscopy unit with the goal of improving performance. We prospectively audited 500 consecutive colonoscopic procedures and assessed sixty-two process or outcome indicators for each procedure. Most of the measured indicators were within standard limits: cecal intubation rate (92%), inadequate bowel preparations (24%), inappropriate procedures (9.7%), normal procedures (54%), yield for neoplasia (32%), morbidity (0.4%), and overall patient satisfaction (95.8%). Some indicators were outside standard limits suggesting our practices should be modified: endoscopy withdrawal time less than 6 minutes (78%), forceps removal of polyps (31%), resected polyps not recovered for pathological examination (12%), adenomas with villous elements (22%), patients unsatisfied because of time spent waiting for the procedure (19%), patients unsatisfied because of inadequate explanations (10%). There was no standard for a few indicators: patient discomfort (6.9%), diagnostic success (89%), therapeutic success (92%). Three new indicators were proposed: proportion of patients aged<50 years, number of normal colonoscopic procedures to perform to detect one advanced adenoma or cancer, and proportion of colonoscopic procedures causing discomfort. The diagnostic yield of colonoscopy was dependent on age, gender, indication and appropriateness of indication but not on the prescriber. This audit allowed us to evaluate our endoscopic practices and to detect certain shortcomings and deviations from standards. It enabled us to change some of our practices with the goal of improving the quality of our colonoscopic procedures.

  9. Operational CryoSat Product Quality Assessment

    NASA Astrophysics Data System (ADS)

    Mannan, Rubinder; Webb, Erica; Hall, Amanda; Bouzinac, Catherine

    2013-12-01

    The performance and quality of the CryoSat data products are routinely assessed by the Instrument Data quality Evaluation and Analysis Service (IDEAS). This information is then conveyed to the scientific and user community in order to allow them to utilise CryoSat data with confidence. This paper presents details of the Quality Control (QC) activities performed for CryoSat products under the IDEAS contract. Details of the different QC procedures and tools deployed by IDEAS to assess the quality of operational data are presented. The latest updates to the Instrument Processing Facility (IPF) for the Fast Delivery Marine (FDM) products and the future update to Baseline-C are discussed.

  10. Implementing self sustained quality control procedures in a clinical laboratory.

    PubMed

    Khatri, Roshan; K C, Sanjay; Shrestha, Prabodh; Sinha, J N

    2013-01-01

    Quality control is an essential component in every clinical laboratory which maintains the excellence of laboratory standards, supplementing to proper disease diagnosis, patient care and resulting in overall strengthening of health care system. Numerous quality control schemes are available, with combinations of procedures, most of which are tedious, time consuming and can be "too technical" whereas commercially available quality control materials can be expensive especially for laboratories in developing nations like Nepal. Here, we present a procedure performed at our centre with self prepared control serum and use of simple statistical tools for quality assurance. The pooled serum was prepared as per guidelines for preparation of stabilized liquid quality control serum from human sera. Internal Quality Assessment was performed on this sample, on a daily basis which included measurement of 12 routine biochemical parameters. The results were plotted on Levey-Jennings charts and analysed with quality control rules, for a period of one month. The mean levels of biochemical analytes in self prepared control serum were within normal physiological range. This serum was evaluated every day along with patients' samples. The results obtained were plotted on control charts and analysed using common quality control rules to identify possible systematic and random errors. Immediate mitigation measures were taken and the dispatch of erroneous reports was avoided. In this study we try to highlight on a simple internal quality control procedure which can be performed by laboratories, with minimum technology, expenditure, and expertise and improve reliability and validity of the test reports.

  11. Validity of portfolio assessment: which qualities determine ratings?

    PubMed

    Driessen, Erik W; Overeem, Karlijn; van Tartwijk, Jan; van der Vleuten, Cees P M; Muijtjens, Arno M M

    2006-09-01

    The portfolio is becoming increasingly accepted as a valuable tool for learning and assessment. The validity of portfolio assessment, however, may suffer from bias due to irrelevant qualities, such as lay-out and writing style. We examined the possible effects of such qualities in a portfolio programme aimed at stimulating Year 1 medical students to reflect on their professional and personal development. In later curricular years, this portfolio is also used to judge clinical competence. We developed an instrument, the Portfolio Analysis Scoring Inventory, to examine the impact of form and content aspects on portfolio assessment. The Inventory consists of 15 items derived from interviews with experienced mentors, the literature, and the criteria for reflective competence used in the regular portfolio assessment procedure. Forty portfolios, selected from 231 portfolios for which ratings from the regular assessment procedure were available, were rated by 2 researchers, independently, using the Inventory. Regression analysis was used to estimate the correlation between the ratings from the regular assessment and those resulting from the Inventory items. Inter-rater agreement ranged from 0.46 to 0.87. The strongest predictor of the variance in the regular ratings was 'quality of reflection' (R 0.80; R2 66%). No further items accounted for a significant proportion of variance. Irrelevant items, such as writing style and lay-out, had negligible effects. The absence of an impact of irrelevant criteria appears to support the validity of the portfolio assessment procedure. Further studies should examine the portfolio's validity for the assessment of clinical competence.

  12. Impacts of Climate Policy on Regional Air Quality, Health, and Air Quality Regulatory Procedures

    NASA Astrophysics Data System (ADS)

    Thompson, T. M.; Selin, N. E.

    2011-12-01

    Both the changing climate, and the policy implemented to address climate change can impact regional air quality. We evaluate the impacts of potential selected climate policies on modeled regional air quality with respect to national pollution standards, human health and the sensitivity of health uncertainty ranges. To assess changes in air quality due to climate policy, we couple output from a regional computable general equilibrium economic model (the US Regional Energy Policy [USREP] model), with a regional air quality model (the Comprehensive Air Quality Model with Extensions [CAMx]). USREP uses economic variables to determine how potential future U.S. climate policy would change emissions of regional pollutants (CO, VOC, NOx, SO2, NH3, black carbon, and organic carbon) from ten emissions-heavy sectors of the economy (electricity, coal, gas, crude oil, refined oil, energy intensive industry, other industry, service, agriculture, and transportation [light duty and heavy duty]). Changes in emissions are then modeled using CAMx to determine the impact on air quality in several cities in the Northeast US. We first calculate the impact of climate policy by using regulatory procedures used to show attainment with National Ambient Air Quality Standards (NAAQS) for ozone and particulate matter. Building on previous work, we compare those results with the calculated results and uncertainties associated with human health impacts due to climate policy. This work addresses a potential disconnect between NAAQS regulatory procedures and the cost/benefit analysis required for and by the Clean Air Act.

  13. Field test of a bioassay procedure for assessing habitat quality on fish spawning grounds

    USGS Publications Warehouse

    Manny, Bruce A.; Jude, David J.; Eshenroder, Randy L.

    1989-01-01

    A bioassay procedure to assess habitat quality was tested on Port Austin reef in southern Lake Huron, a spawning area of lake trout Salvelinus namaycush. In 1986, Plexiglas incubators filled with fertilized lake trout eggs were buried by scuba divers in rock rubble at two sites. The incubators then were attached to chains between large trap-net anchors on the bottom and left over winter. At one site, egg hatch rate was significantly higher in incubators that remained buried in substrate (24%) than in incubators that were dislodged out onto the substrate (13%). At the other, more exposed site, no significant difference was found in percent hatch between eggs that incubated in (10%) and on (8%) the substrate. Percent hatch at both sites was significantly lower than that (40%) of eggs from the same source that were incubated in controlled laboratory conditions. In autumn, concentrations of dissolved ammonia, hydrogen sulfide, and nitrate near bottom and in the substrate posed no threat to lake trout embryos and were not correlated with hatch rate; concentrations differed significantly between the two sites. During winter, 15 cm of sediment settled from the water onto the reef but did not accumulate or smother the eggs. The bioassay procedure is easy to implement, is recommended for use in the Great Lakes, and could be adapted easily for use elsewhere.

  14. Towards an integrated quality control procedure for eddy-covariance data

    NASA Astrophysics Data System (ADS)

    Vitale, Domenico; Papale, Dario

    2017-04-01

    The eddy-covariance technique is nowadays the most reliable and direct way, allowing to calculate the main fluxes of Sensible and Latent Heat and of Net Ecosystem Exchange, this last being the result of the difference between the CO2 assimilated by photosynthetic activities and those released to the atmosphere through the ecosystem respiration processes. Despite the improvements in accuracy of measurement instruments and software development, the eddy-covariance technique is not suitable under non-ideal conditions respect to the instruments characteristics and the physical assumption behind the technique mainly related to the well-developed and stationary turbulence conditions. Under these conditions the calculated fluxes are not reliable and need to be flagged and discarded. In order to discover these unavoidable "bad" fluxes and build dataset with the highest quality, several tests applied both on high-frequency (10-20 Hz) raw data and on half-hourly times series have been developed in the past years. Nevertheless, there is an increasing need to develop a standardized quality control procedure suitable not only for the analysis of long-term data, but also for the near-real time data processing. In this paper, we review established quality assessment procedures and present an innovative quality control strategy with the purpose of integrating the existing consolidated procedures with robust and advanced statistical tests more suitable for the analysis of time series data. The performance of the proposed quality control strategy is evaluated both on simulated and EC data distributed by the ICOS research infrastructure. It is concluded that the proposed strategy is able to flag and exclude unrealistic fluxes while being reproducible and retaining the largest possible amount of high quality data.

  15. The University of Texas Houston Stroke Registry (UTHSR): implementation of enhanced data quality assurance procedures improves data quality

    PubMed Central

    2013-01-01

    Background Limited information has been published regarding standard quality assurance (QA) procedures for stroke registries. We share our experience regarding the establishment of enhanced QA procedures for the University of Texas Houston Stroke Registry (UTHSR) and evaluate whether these QA procedures have improved data quality in UTHSR. Methods All 5093 patient records that were abstracted and entered in UTHSR, between January 1, 2008 and December 31, 2011, were considered in this study. We conducted reliability and validity studies. For reliability and validity of data captured by abstractors, a random subset of 30 records was used for re-abstraction of select key variables by two abstractors. These 30 records were re-abstracted by a team of experts that included a vascular neurologist clinician as the “gold standard”. We assessed inter-rater reliability (IRR) between the two abstractors as well as validity of each abstractor with the “gold standard”. Depending on the scale of variables, IRR was assessed with Kappa or intra-class correlations (ICC) using a 2-way, random effects ANOVA. For assessment of validity of data in UTHSR we re-abstracted another set of 85 patient records for which all discrepant entries were adjudicated by a vascular neurology fellow clinician and added to the set of our “gold standard”. We assessed level of agreement between the registry data and the “gold standard” as well as sensitivity and specificity. We used logistic regression to compare error rates for different years to assess whether a significant improvement in data quality has been achieved during 2008–2011. Results The error rate dropped significantly, from 4.8% in 2008 to 2.2% in 2011 (P < 0.001). The two abstractors had an excellent IRR (Kappa or ICC ≥ 0.75) on almost all key variables checked. Agreement between data in UTHSR and the “gold standard” was excellent for almost all categorical and continuous variables. Conclusions Establishment of a

  16. Prospective Cohort Study Investigating Changes in Body Image, Quality of Life, and Self-Esteem Following Minimally Invasive Cosmetic Procedures.

    PubMed

    Sobanko, Joseph F; Dai, Julia; Gelfand, Joel M; Sarwer, David B; Percec, Ivona

    2018-04-13

    Minimally invasive cosmetic injectable procedures are increasingly common. However, a few studies have investigated changes in psychosocial functioning following these treatments. To assess changes in body image, quality of life, and self-esteem following cosmetic injectable treatment with soft tissue fillers and neuromodulators. Open, prospective study of 75 patients undergoing cosmetic injectable procedures for facial aging to evaluate changes in psychosocial functioning within 6 weeks of treatment. Outcome measures included the Derriford appearance scale (DAS-24), body image quality of life inventory (BIQLI), and the Rosenberg self-esteem scale. Body image dissatisfaction, as assessed by the DAS-24, improved significantly 6 weeks after the treatment. Body image quality of life, as assessed by the BIQLI, improved, but the change did not reach statistical significance. Self-esteem was unchanged after the treatment. Minimally invasive cosmetic injectable procedures were associated with reductions in body image dissatisfaction. Future research, using recently developed cosmetic surgery-specific instruments, may provide further insight into the psychosocial benefits of minimally invasive procedures.

  17. Pollutant Assessments Group procedures manual: Volume 2, Technical procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-03-01

    This is volume 2 of the manuals that describes the technical procedures currently in use by the Pollution Assessments Group. This manual incorporates new developments in hazardous waste assessment technology and administrative policy. Descriptions of the equipment, procedures and operations of such things as radiation detection, soil sampling, radionuclide monitoring, and equipment decontamination are included in this manual. (MB)

  18. Economic Assessment and Budgetary Impact of a Telemedicine Procedure and Spirometry Quality Control in the Primary Care Setting.

    PubMed

    Marina, Nuria; Bayón, Juan Carlos; López de Santa María, Elena; Gutiérrez, Asunción; Inchausti, Marta; Bustamante, Victor; Gáldiz, Juan B

    2016-01-01

    To evaluate the economic impact of a telemedicine procedure designed to improve the quality of lung function testing (LFT) in primary care in a public healthcare system, compared with the standard method. The economic impact of 9,039 LFTs performed in 51 health centers (2010-2013) using telespirometry (TS) compared to standard spirometry (SS) was studied. TS costs more per unit than SS (€47.80 vs. €39.70) (2013), but the quality of the TS procedure is superior (84% good quality, compared to 61% using the standard procedure). Total cost of TS was €431,974 (compared with €358,306€ for SS), generating an economic impact of €73,668 (2013). The increase in cost for good quality LFT performed using TS was €34,030 (2010) and €144,295 (2013), while the costs of poor quality tests fell by €15,525 (2010) and 70,627€ (2013). The cost-effectiveness analysis concludes that TS is 23% more expensive and 46% more effective. Healthcare costs consequently fall as the number of LFTs performed by TS rises. Avoiding poor quality, invalid LFTs generates savings that compensate for the increased costs of performing LFTs with TS, making it a cost-effective method. Copyright © 2014 SEPAR. Published by Elsevier Espana. All rights reserved.

  19. Development and application of a statistical quality assessment method for dense-graded mixes.

    DOT National Transportation Integrated Search

    2004-08-01

    This report describes the development of the statistical quality assessment method and the procedure for mapping the measures obtained from the quality assessment method to a composite pay factor. The application to dense-graded mixes is demonstrated...

  20. 40 CFR Appendix C to Part 61 - Quality Assurance Procedures

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Quality Assurance Procedures C Appendix C to Part 61 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...—Quality Assurance Procedures Procedure 1—Determination of Adequate Chromatographic Peak Resolution In this...

  1. [Evaluation of quality of HIV diagnostic procedures in Poland].

    PubMed

    Parczewski, Miłosz; Madaliński, Kazimierz; Leszczyszyn-Pynka, Magdalena; Boroń-Kaczmarska, Anna

    2010-01-01

    The aim of this work was quality assessment of HIV diagnostic procedures in Poland, including human and technical resources as well as laboratory practice. Sixty questionnaires were distributed among diagnostic centers to obtain qualitative data. Basing on the survey data serological control using coded panels of HIV-1/2 samples was performed. Thirty-one filled questionnaires were received (50.8%). Surveyed laboratories perform from 350 to 5500 serological screening tests per year. In most of laboratories fourth generation assays are available, while Blood Donation Centers screen the blood both with serological assays and by HIV-RNA detection. Sanitary and Epidemiological Stations and academic laboratories hold the ISO/IEC 17025 or IS0 9001:2001 accreditation, five of the surveyed centers participate in Labquality assurance and two in Quality Control in Molecular Diagnostics programs. Data of control serological testing were received from 21 centers. In the quality control assessment 194 analyses were performed with 91 true negative, 2 false negative, 96 true positive and 5 false positive results. False negative rate of % and false positive rate of 5.2% was noted for this study. Currently, virtually no guidelines related to the HIV-diagnostics quality assurance and control in Poland are in delineated. Development of the national unified quality control system, basing on the central institution is highly desirable. National certification within the frames of the quality control and assurance program should be mandatory for all the diagnostic labs, and aim at improvement of reliability of the result distributed among clinicians and patients.

  2. Comparing preference assessments: selection- versus duration-based preference assessment procedures.

    PubMed

    Kodak, Tiffany; Fisher, Wayne W; Kelley, Michael E; Kisamore, April

    2009-01-01

    In the current investigation, the results of a selection- and a duration-based preference assessment procedure were compared. A Multiple Stimulus With Replacement (MSW) preference assessment [Windsor, J., Piché, L. M., & Locke, P. A. (1994). Preference testing: A comparison of two presentation methods. Research in Developmental Disabilities, 15, 439-455] and a variation of a Free-Operant (FO) preference assessment procedure [Roane, H. S., Vollmer, T. R., Ringdahl, J. E., & Marcus, B. A. (1998). Evaluation of a brief stimulus preference assessment. Journal of Applied Behavior Analysis, 31, 605-620] were conducted with four participants. A reinforcer assessment was conducted to determine which preference assessment procedure identified the item that produced the highest rates of responding. The items identified as most highly preferred were different across preference assessment procedures for all participants. Results of the reinforcer assessment showed that the MSW identified the item that functioned as the most effective reinforcer for two participants.

  3. Guidelines and standard procedures for continuous water-quality monitors: Station operation, record computation, and data reporting

    USGS Publications Warehouse

    Wagner, Richard J.; Boulger, Robert W.; Oblinger, Carolyn J.; Smith, Brett A.

    2006-01-01

    The U.S. Geological Survey uses continuous water-quality monitors to assess the quality of the Nation's surface water. A common monitoring-system configuration for water-quality data collection is the four-parameter monitoring system, which collects temperature, specific conductance, dissolved oxygen, and pH data. Such systems also can be configured to measure other properties, such as turbidity or fluorescence. Data from sensors can be used in conjunction with chemical analyses of samples to estimate chemical loads. The sensors that are used to measure water-quality field parameters require careful field observation, cleaning, and calibration procedures, as well as thorough procedures for the computation and publication of final records. This report provides guidelines for site- and monitor-selection considerations; sensor inspection and calibration methods; field procedures; data evaluation, correction, and computation; and record-review and data-reporting processes, which supersede the guidelines presented previously in U.S. Geological Survey Water-Resources Investigations Report WRIR 00-4252. These procedures have evolved over the past three decades, and the process continues to evolve with newer technologies.

  4. Measuring and Improving the Quality of Preprocedural Assessments.

    PubMed

    Manji, Farah; McCarty, Kelsey; Kurzweil, Vanessa; Mark, Eden; Rathmell, James P; Agarwala, Aalok V

    2017-06-01

    Preprocedural assessments are used by anesthesia providers to optimize perioperative care for patients undergoing invasive procedures. When these assessments are performed in advance by providers who are not caring for the patient during the procedure, there is an additional layer of complexity in ensuring that the workup meets the needs of the primary anesthesia care team. In this study, anesthesia providers were asked to rate the quality of preprocedural assessments prepared by other providers to evaluate anesthesia care team satisfaction. Quality ratings for preprocedural assessments were collected from anesthesia providers on the day of surgery using an electronic quality assurance tool from January 9, 2014 to October 21, 2014. Users could rate assessments as "exemplary," "satisfactory," or "unsatisfactory." Free text comments could be entered for any of the quality ratings chosen. A reviewer trained in clinical anesthesia categorized all comments as "positive," "constructive," or "neutral" and conducted in-depth chart reviews triggered by 67 "constructive" comments submitted during the first 3 months of data collection to further subcategorize perceived deficiencies in the preprocedural assessments. In May 2014, providers were asked to participate in a midpoint survey and provide general feedback about the preprocedural process and evaluations. 37,611 procedures requiring anesthesia were analyzed. Of the 17,522 (46.6%) cases with a rated preprocedural assessment, anesthesia providers rated 3828 (21.8%) as "exemplary," 13,454 (76.8%) as "satisfactory," and 240 (1.4%) as "unsatisfactory." The monthly proportion of "unsatisfactory" ratings ranged from 3.1% to 0% over the study period, whereas the midpoint survey showed that anesthesia providers estimated that the number of unsatisfactory evaluations was 11.5%. Preprocedural evaluations performed on inpatients received significantly better ratings than evaluations performed on outpatients by the preadmission

  5. [Certification assessment and quality and risk management].

    PubMed

    Papin-Morardet, Maud

    2018-03-01

    Organised by the French National Health Authority (HAS), certification is an external assessment process which is obligatory for all public and private health facilities, whatever their size or activity. The aim is to independently evaluate the quality of the health care provision of hospitals and clinics in France. This article looks at the investigation methods and the procedure used during the certification assessment of Henri Mondor University Hospitals in 2016. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  6. Quality, management, and the interplay of self-assessment, process assessments, and performance-based observations

    NASA Astrophysics Data System (ADS)

    Willett, D. J.

    1993-04-01

    In this document, the author presents his observations on the topic of quality assurance (QA). Traditionally the focus of quality management has been on QA organizations, manuals, procedures, audits, and assessments; quality was measured by the degree of conformance to specifications or standards. Today quality is defined as satisfying user needs and is measured by user satisfaction. The author proposes that quality is the responsibility of line organizations and staff and not the responsibility of the QA group. This work outlines an effective Conduct of Operations program. The author concludes his observations with a discussion of how quality is analogous to leadership.

  7. HANDBOOK: QUALITY ASSURANCE/QUALITY CONTROL (QA/QC) PROCEDURES FOR HAZARDOUS WASTE INCINERATION

    EPA Science Inventory

    Resource Conservation and Recovery Act regulations for hazardous waste incineration require trial burns by permit applicants. uality Assurance Project Plan (QAPjP) must accompany a trial burn plan with appropriate quality assurance/quality control procedures. uidance on the prepa...

  8. Assessing early unplanned reoperations in neurosurgery: opportunities for quality improvement.

    PubMed

    McLaughlin, Nancy; Jin, Peng; Martin, Neil A

    2015-07-01

    Review of morbidities and mortality has been the primary method used to assess surgical quality by physicians, hospitals, and oversight agencies. The incidence of reoperation has been proposed as a candidate quality indicator for surgical care. The authors report a comprehensive assessment of reoperations within a neurosurgical department and discuss how such data can be integrated into quality improvement initiatives to optimize value of care delivery. All neurosurgical procedures performed in the main operating room or the outpatient surgery center at the Ronald Reagan UCLA Medical Center and UCLA Santa Monica Medical Center from July 2008 to December 2012 were considered for this study. Interventional radiology and stereotactic radiosurgery procedures were excluded. Early reoperations within 7 days of the index surgery were reviewed and their preventability status was evaluated. The incidence of early unplanned reoperation was 2.6% (occurring after 183 of 6912 procedures). More than half of the patients who underwent early unplanned reoperation initially had surgery for shunt-related conditions (34.4%) or intracranial tumor (23.5%). Shunt failure was the most common indication for early unplanned reoperation (34.4%), followed by postoperative bleeding (20.8%) and postoperative elevated intracranial pressure (9.8%). The average time interval (± SD) between the index surgery and reoperation was 3.0 ± 1.9 days. The average length of stay following reoperation was 12.1 ± 14.4 days. This study enabled an in-depth assessment of reoperations within an academic neurosurgical practice and identification of strategic opportunities for department-wide quality improvement initiatives. The authors provide a nuanced discussion regarding the use of absolute reoperations as a quality indicator for neurosurgical patient populations.

  9. Assessing Procedural Competence: Validity Considerations.

    PubMed

    Pugh, Debra M; Wood, Timothy J; Boulet, John R

    2015-10-01

    Simulation-based medical education (SBME) offers opportunities for trainees to learn how to perform procedures and to be assessed in a safe environment. However, SBME research studies often lack robust evidence to support the validity of the interpretation of the results obtained from tools used to assess trainees' skills. The purpose of this paper is to describe how a validity framework can be applied when reporting and interpreting the results of a simulation-based assessment of skills related to performing procedures. The authors discuss various sources of validity evidence because they relate to SBME. A case study is presented.

  10. Enhancement of the Automated Quality Control Procedures for the International Soil Moisture Network

    NASA Astrophysics Data System (ADS)

    Heer, Elsa; Xaver, Angelika; Dorigo, Wouter; Messner, Romina

    2017-04-01

    In-situ soil moisture observations are still trusted to be the most reliable data to validate remotely sensed soil moisture products. Thus, the quality of in-situ soil moisture observations is of high importance. The International Soil Moisture Network (ISMN; http://ismn.geo.tuwien.ac.at/) provides in-situ soil moisture data from all around the world. The data is collected from individual networks and data providers, measured by different sensors in various depths. The data sets which are delivered in different units, time zones and data formats are then transformed into homogeneous data sets. An erroneous behavior of soil moisture data is very difficult to detect, due to annual and daily changes and most significantly the high influence of precipitation and snow melting processes. Only few of the network providers have a quality assessment for their data sets. Therefore, advanced quality control procedures have been developed for the ISMN (Dorigo et al. 2013). Three categories of quality checks were introduced: exceeding boundary values, geophysical consistency checks and a spectrum based approach. The spectrum based quality control algorithms aim to detect erroneous measurements which occur within plausible geophysical ranges, e.g. a sudden drop in soil moisture caused by a sensor malfunction. By defining several conditions which have to be met by the original soil moisture time series and their first and second derivative, such error types can be detected. Since the development of these sophisticated methods many more data providers shared their data with the ISMN and new types of erroneous measurements were identified. Thus, an enhancement of the automated quality control procedures became necessary. In the present work, we introduce enhancements of the existing quality control algorithms. Additionally, six completely new quality checks have been developed, e.g. detection of suspicious values before or after NAN-values, constant values and values that lie in a

  11. Teaching and assessing procedural skills: a qualitative study

    PubMed Central

    2013-01-01

    Background Graduating Internal Medicine residents must possess sufficient skills to perform a variety of medical procedures. Little is known about resident experiences of acquiring procedural skills proficiency, of practicing these techniques, or of being assessed on their proficiency. The purpose of this study was to qualitatively investigate resident 1) experiences of the acquisition of procedural skills and 2) perceptions of procedural skills assessment methods available to them. Methods Focus groups were conducted in the weeks following an assessment of procedural skills incorporated into an objective structured clinical examination (OSCE). Using fundamental qualitative description, emergent themes were identified and analyzed. Results Residents perceived procedural skills assessment on the OSCE as a useful formative tool for direct observation and immediate feedback. This positive reaction was regularly expressed in conjunction with a frustration with available assessment systems. Participants reported that proficiency was acquired through resident directed learning with no formal mechanism to ensure acquisition or maintenance of skills. Conclusions The acquisition and assessment of procedural skills in Internal Medicine programs should move toward a more structured system of teaching, deliberate practice and objective assessment. We propose that directed, self-guided learning might meet these needs. PMID:23672617

  12. Teaching and assessing procedural skills: a qualitative study.

    PubMed

    Touchie, Claire; Humphrey-Murto, Susan; Varpio, Lara

    2013-05-14

    Graduating Internal Medicine residents must possess sufficient skills to perform a variety of medical procedures. Little is known about resident experiences of acquiring procedural skills proficiency, of practicing these techniques, or of being assessed on their proficiency. The purpose of this study was to qualitatively investigate resident 1) experiences of the acquisition of procedural skills and 2) perceptions of procedural skills assessment methods available to them. Focus groups were conducted in the weeks following an assessment of procedural skills incorporated into an objective structured clinical examination (OSCE). Using fundamental qualitative description, emergent themes were identified and analyzed. Residents perceived procedural skills assessment on the OSCE as a useful formative tool for direct observation and immediate feedback. This positive reaction was regularly expressed in conjunction with a frustration with available assessment systems. Participants reported that proficiency was acquired through resident directed learning with no formal mechanism to ensure acquisition or maintenance of skills. The acquisition and assessment of procedural skills in Internal Medicine programs should move toward a more structured system of teaching, deliberate practice and objective assessment. We propose that directed, self-guided learning might meet these needs.

  13. A review of data quality assessment methods for public health information systems.

    PubMed

    Chen, Hong; Hailey, David; Wang, Ning; Yu, Ping

    2014-05-14

    High quality data and effective data quality assessment are required for accurately evaluating the impact of public health interventions and measuring public health outcomes. Data, data use, and data collection process, as the three dimensions of data quality, all need to be assessed for overall data quality assessment. We reviewed current data quality assessment methods. The relevant study was identified in major databases and well-known institutional websites. We found the dimension of data was most frequently assessed. Completeness, accuracy, and timeliness were the three most-used attributes among a total of 49 attributes of data quality. The major quantitative assessment methods were descriptive surveys and data audits, whereas the common qualitative assessment methods were interview and documentation review. The limitations of the reviewed studies included inattentiveness to data use and data collection process, inconsistency in the definition of attributes of data quality, failure to address data users' concerns and a lack of systematic procedures in data quality assessment. This review study is limited by the coverage of the databases and the breadth of public health information systems. Further research could develop consistent data quality definitions and attributes. More research efforts should be given to assess the quality of data use and the quality of data collection process.

  14. A Review of Data Quality Assessment Methods for Public Health Information Systems

    PubMed Central

    Chen, Hong; Hailey, David; Wang, Ning; Yu, Ping

    2014-01-01

    High quality data and effective data quality assessment are required for accurately evaluating the impact of public health interventions and measuring public health outcomes. Data, data use, and data collection process, as the three dimensions of data quality, all need to be assessed for overall data quality assessment. We reviewed current data quality assessment methods. The relevant study was identified in major databases and well-known institutional websites. We found the dimension of data was most frequently assessed. Completeness, accuracy, and timeliness were the three most-used attributes among a total of 49 attributes of data quality. The major quantitative assessment methods were descriptive surveys and data audits, whereas the common qualitative assessment methods were interview and documentation review. The limitations of the reviewed studies included inattentiveness to data use and data collection process, inconsistency in the definition of attributes of data quality, failure to address data users’ concerns and a lack of systematic procedures in data quality assessment. This review study is limited by the coverage of the databases and the breadth of public health information systems. Further research could develop consistent data quality definitions and attributes. More research efforts should be given to assess the quality of data use and the quality of data collection process. PMID:24830450

  15. Neurodevelopmental Outcome and Health-related Quality of Life in Children With Single-ventricle Heart Disease Before Fontan Procedure.

    PubMed

    Reich, Bettina; Heye, Kristina; Tuura, Ruth; Beck, Ingrid; Wetterling, Kristina; Hahn, Andreas; Hofmann, Karoline; Schranz, Dietmar; Akintürk, Hakan; Latal, Beatrice; Knirsch, Walter

    2017-12-05

    Neurodevelopmental impairment and impaired quality of life constitute a major source of morbidity among children with complex congenital heart disease, in particular for single-ventricle (SV) morphologies. Risk factors and quality of life determining clinical and neurodevelopmental outcome at 2 years of age are examined. In a 2-center cohort study, 48 patients with SV morphology (26 hypoplastic left heart syndrome and 22 other types of univentricular heart defect) have been examined before Fontan procedure between 2010 and 2015. Patients were assessed with the Bayley Scales of Infant and Toddler Development, Third Version (Bayley-III), and the Preschool Children Quality of Life (TAPQOL) questionnaire. A total of 44 patients underwent hybrid procedure (n = 25), Norwood procedure (n = 7), or shunt or banding procedure (n = 12) as first surgery before subsequent bidirectional cavopulmonary anastomosis (n = 48). Median cognitive, language, and motor composite scores on the Bayley-III were 100 (range 65-120), 97 (68-124), and 97 (55-124), respectively. The language composite score was significantly below the norm (P = 0.025). Risk factors for poorer neurodevelopmental outcome were prolonged mechanical ventilation, longer days of hospital stay, and more reinterventions (all P < 0.05). Parents reported a good quality of life for their children. Children undergoing Fontan procedure show a favorable development and good quality of life. More complicated postoperative course and reinterventions constitute risk factors for impaired neurodevelopment. Improving postoperative management and implementing routine follow-up assessments aremeasures to further improve the neurodevelopmental outcome of this high-risk patient population. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Criteria for assessment of bridge aesthetic and visual quality

    NASA Astrophysics Data System (ADS)

    Rozentale, I.; Paeglitis, A.

    2017-10-01

    The bridge designers should find an ideal balance between structure, economy, buildability, aesthetics, durability and harmony with industrial or natural landscape. During the last years, the society has adopted documents providing procedures for evaluation of the impact of the structural appearance on surrounding landscape. The European Landscape Convention defines the landscape as an area perceived by people, whose character is the result of the action and interaction of natural and/or human factors. The Convention indicates the methods for clear and objective assessment of the landscape’s visual qualities. The esthetical qualities of bridge structures, appearance and attraction should satisfy not only the technicians - engineers and architects, but mostly the surrounding population. Each of these groups has a different perception of esthetical qualities of structure. Many authors have used different methods and criteria for assessment of bridge aesthetics. The aim of this paper is to provide an overview of the bridge aesthetic and visual quality assessment methods and criteria.

  17. Guidelines and standard procedures for continuous water-quality monitors: Site selection, field operation, calibration, record computation, and reporting

    USGS Publications Warehouse

    Wagner, Richard J.; Mattraw, Harold C.; Ritz, George F.; Smith, Brett A.

    2000-01-01

    The U.S. Geological Survey uses continuous water-quality monitors to assess variations in the quality of the Nation's surface water. A common system configuration for data collection is the four-parameter water-quality monitoring system, which collects temperature, specific conductance, dissolved oxygen, and pH data, although systems can be configured to measure other properties such as turbidity or chlorophyll. The sensors that are used to measure these water properties require careful field observation, cleaning, and calibration procedures, as well as thorough procedures for the computation and publication of final records. Data from sensors can be used in conjunction with collected samples and chemical analyses to estimate chemical loads. This report provides guidelines for site-selection considerations, sensor test methods, field procedures, error correction, data computation, and review and publication processes. These procedures have evolved over the past three decades, and the process continues to evolve with newer technologies.

  18. Endorsing good quality assurance practices in molecular pathology: risks and recommendations for diagnostic laboratories and external quality assessment providers.

    PubMed

    Tembuyser, Lien; Dequeker, Elisabeth M C

    2016-01-01

    Quality assurance is an indispensable element in a molecular diagnostic laboratory. The ultimate goal is to warrant patient safety. Several risks that can compromise high quality procedures are at stake, from sample collection to the test performed by the laboratory, the reporting of test results to clinicians, and the organization of effective external quality assessment schemes. Quality assurance should therefore be safeguarded at each level and should imply a holistic multidisciplinary approach. This review aims to provide an overview of good quality assurance practices and discusses certain risks and recommendations to promote and improve quality assurance for both diagnostic laboratories and for external quality assessment providers. The number of molecular targets is continuously rising, and new technologies are evolving. As this poses challenges for clinical implementation and increases the demand for external quality assessment, the formation of an international association for improving quality assurance in molecular pathology is called for.

  19. Water-quality sampling by the U.S. Geological Survey-Standard protocols and procedures

    USGS Publications Warehouse

    Wilde, Franceska D.

    2010-01-01

    Thumbnail of and link to report PDF (1.0 MB) The U.S. Geological Survey (USGS) develops the sampling procedures and collects the data necessary for the accurate assessment and wise management of our Nation's surface-water and groundwater resources. Federal and State agencies, water-resource regulators and managers, and many organizations and interested parties in the public and private sectors depend on the reliability, timeliness, and integrity of the data we collect and the scientific soundness and impartiality of our data assessments and analysis. The standard data-collection methods uniformly used by USGS water-quality personnel are peer reviewed, kept up-to-date, and published in the National Field Manual for the Collection of Water-Quality Data (http://pubs.water.usgs.gov/twri9A/).

  20. Quality control and quality assurance plan for bridge channel-stability assessments in Massachusetts

    USGS Publications Warehouse

    Parker, Gene W.; Pinson, Harlow

    1993-01-01

    A quality control and quality assurance plan has been implemented as part of the Massachusetts bridge scour and channel-stability assessment program. This program is being conducted by the U.S. Geological Survey, Massachusetts-Rhode Island District, in cooperation with the Massachusetts Highway Department. Project personnel training, data-integrity verification, and new data-management technologies are being utilized in the channel-stability assessment process to improve current data-collection and management techniques. An automated data-collection procedure has been implemented to standardize channel-stability assessments on a regular basis within the State. An object-oriented data structure and new image management tools are used to produce a data base enabling management of multiple data object classes. Data will be reviewed by assessors and data base managers before being merged into a master bridge-scour data base, which includes automated data-verification routines.

  1. 42 CFR 476.160 - General quality of care review procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 4 2013-10-01 2013-10-01 false General quality of care review procedures. 476.160... SERVICES (CONTINUED) QUALITY IMPROVEMENT ORGANIZATIONS UTILIZATION AND QUALITY CONTROL REVIEW Review Responsibilities of Utilization and Quality Control Quality Improvement Organizations (QIOs) Qio Review Functions...

  2. 42 CFR 476.160 - General quality of care review procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 4 2014-10-01 2014-10-01 false General quality of care review procedures. 476.160... SERVICES (CONTINUED) QUALITY IMPROVEMENT ORGANIZATIONS QUALITY IMPROVEMENT ORGANIZATION REVIEW Review Responsibilities of Quality Improvement Organizations (QIOs) Qio Review Functions § 476.160 General quality of care...

  3. Doctors or technicians: assessing quality of medical education

    PubMed Central

    Hasan, Tayyab

    2010-01-01

    Medical education institutions usually adapt industrial quality management models that measure the quality of the process of a program but not the quality of the product. The purpose of this paper is to analyze the impact of industrial quality management models on medical education and students, and to highlight the importance of introducing a proper educational quality management model. Industrial quality management models can measure the training component in terms of competencies, but they lack the educational component measurement. These models use performance indicators to assess their process improvement efforts. Researchers suggest that the performance indicators used in educational institutions may only measure their fiscal efficiency without measuring the quality of the educational experience of the students. In most of the institutions, where industrial models are used for quality assurance, students are considered as customers and are provided with the maximum services and facilities possible. Institutions are required to fulfill a list of recommendations from the quality control agencies in order to enhance student satisfaction and to guarantee standard services. Quality of medical education should be assessed by measuring the impact of the educational program and quality improvement procedures in terms of knowledge base development, behavioral change, and patient care. Industrial quality models may focus on academic support services and processes, but educational quality models should be introduced in parallel to focus on educational standards and products. PMID:23745059

  4. Doctors or technicians: assessing quality of medical education.

    PubMed

    Hasan, Tayyab

    2010-01-01

    Medical education institutions usually adapt industrial quality management models that measure the quality of the process of a program but not the quality of the product. The purpose of this paper is to analyze the impact of industrial quality management models on medical education and students, and to highlight the importance of introducing a proper educational quality management model. Industrial quality management models can measure the training component in terms of competencies, but they lack the educational component measurement. These models use performance indicators to assess their process improvement efforts. Researchers suggest that the performance indicators used in educational institutions may only measure their fiscal efficiency without measuring the quality of the educational experience of the students. In most of the institutions, where industrial models are used for quality assurance, students are considered as customers and are provided with the maximum services and facilities possible. Institutions are required to fulfill a list of recommendations from the quality control agencies in order to enhance student satisfaction and to guarantee standard services. Quality of medical education should be assessed by measuring the impact of the educational program and quality improvement procedures in terms of knowledge base development, behavioral change, and patient care. Industrial quality models may focus on academic support services and processes, but educational quality models should be introduced in parallel to focus on educational standards and products.

  5. Evaluation of procedures for quality assurance specifications

    DOT National Transportation Integrated Search

    2004-10-01

    The objective of this project was to develop a comprehensive quality assurance (QA) manual, supported by scientific evidence and statistical theory, which provides step-by-step procedures and instructions for developing effective and efficient QA spe...

  6. Automated Assessment of the Quality of Depression Websites

    PubMed Central

    Tang, Thanh Tin; Hawking, David; Christensen, Helen

    2005-01-01

    Background Since health information on the World Wide Web is of variable quality, methods are needed to assist consumers to identify health websites containing evidence-based information. Manual assessment tools may assist consumers to evaluate the quality of sites. However, these tools are poorly validated and often impractical. There is a need to develop better consumer tools, and in particular to explore the potential of automated procedures for evaluating the quality of health information on the web. Objective This study (1) describes the development of an automated quality assessment procedure (AQA) designed to automatically rank depression websites according to their evidence-based quality; (2) evaluates the validity of the AQA relative to human rated evidence-based quality scores; and (3) compares the validity of Google PageRank and the AQA as indicators of evidence-based quality. Method The AQA was developed using a quality feedback technique and a set of training websites previously rated manually according to their concordance with statements in the Oxford University Centre for Evidence-Based Mental Health’s guidelines for treating depression. The validation phase involved 30 websites compiled from the DMOZ, Yahoo! and LookSmart Depression Directories by randomly selecting six sites from each of the Google PageRank bands of 0, 1-2, 3-4, 5-6 and 7-8. Evidence-based ratings from two independent raters (based on concordance with the Oxford guidelines) were then compared with scores derived from the automated AQA and Google algorithms. There was no overlap in the websites used in the training and validation phases of the study. Results The correlation between the AQA score and the evidence-based ratings was high and significant (r=0.85, P<.001). Addition of a quadratic component improved the fit, the combined linear and quadratic model explaining 82 percent of the variance. The correlation between Google PageRank and the evidence-based score was lower than

  7. Quality assessment of patients’ self-monitoring of blood glucose in community pharmacies

    PubMed Central

    Kjome, Reidun L. S.; Granas, Anne G.; Nerhus, Kari; Sandberg, Sverre

    2009-01-01

    Objective To evaluate diabetes patients’ self-monitoring of blood glucose using a community pharmacy-based quality assurance procedure, to investigate whether the procedure improved the quality of the patient performance of self monitoring of blood glucose, and to examine the opinions of the patients taking part in the study. Methods The results of patient blood glucose measurements were compared to the results obtained with HemoCue Glucose 201+ by pharmacy employees in 16 Norwegian community pharmacies. Patient performance was monitored using an eight item checklist. Patients whose blood glucose measurements differed from pharmacy measurements by more than 20% were instructed in the correct use of their glucometer. The patients then re-measured their blood glucose. If the results were still outside the set limits, the control procedure was repeated with a new lot of glucometer strips, and then with a new glucometer. The patients returned for a follow-up visit after three months. Results During the first visit, 5% of the 338 patients had measurements that deviated from pharmacy blood glucose values by more than 20% and user errors were observed for 50% of the patients. At the second visit, there was no significant change in the analytical quality of patient measurements, but the percentage of patients who made user errors had decreased to 29% (p < 0.001). Eighty-five percent of the patients reported that they used their blood glucose results to adjust medication, exercise or meals. Fifty-one percent of the patients reported a greater trust in their measurements after the second visit. Eighty percent of patients wished to have their measurements assessed yearly. Of these patients, 83% preferred to have the assessment done at the community pharmacy. Conclusion A community pharmacy-based quality assessment procedure of patients’ self monitoring of blood glucose significantly reduced the number of user errors. The analytical quality of the patients’ measurements

  8. Headspace screening: A novel approach for fast quality assessment of the essential oil from culinary sage.

    PubMed

    Cvetkovikj, Ivana; Stefkov, Gjoshe; Acevska, Jelena; Karapandzova, Marija; Dimitrovska, Aneta; Kulevanova, Svetlana

    2016-07-01

    Quality assessment of essential oil (EO) from culinary sage (Salvia officinalis L., Lamiaceae) is limited by the long pharmacopoeial procedure. The aim of this study was to employ headspace (HS) sampling in the quality assessment of sage EO. Different populations (30) of culinary sage were assessed using GC/FID/MS analysis of the hydrodistilled EO (pharmacopoeial method) and HS sampling directly from leaves. Compound profiles from both procedures were evaluated according to ISO 9909 and GDC standards for sage EO quality, revealing compliance for only 10 populations. Factors to convert HS values, for the target ISO and GDC components, into theoretical EO values were calculated. Statistical analysis revealed a significant relationship between HS and EO values for seven target components. Consequently, HS sampling could be used as a complementary extraction technique for rapid screening in quality assessment of sage EOs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. 36 CFR 223.197 - Civil penalty assessment procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Relief Act of 1990 Program § 223.197 Civil penalty assessment procedures. Adjudicatory procedures for... 36 Parks, Forests, and Public Property 2 2010-07-01 2010-07-01 false Civil penalty assessment procedures. 223.197 Section 223.197 Parks, Forests, and Public Property FOREST SERVICE, DEPARTMENT OF...

  10. Thoracic Surgery Information on the Internet: A Multilingual Quality Assessment

    PubMed Central

    Davaris, Myles; Barnett, Stephen; Abouassaly, Robert

    2017-01-01

    Background Previous data suggest that quality of Internet information regarding surgical conditions and their treatments is variable. However, no comprehensive analysis of website quality exists for thoracic surgery. Objective The aim of this study was to quantify website quality in a multilingual setting using an international standard for assessment. Methods Health On the Net (HON) principles may be applied to websites using an automated toolbar function. We used the English, French, Spanish, and German Google search engines to identify 12,000 websites using keywords related to thoracic conditions and procedures. The first 150 websites returned by each keyword in each language were examined. We compared website quality to assess for tertile (is the quality better in first, second, or third 50 websites returned) and language differences. A further analysis of the English site types was undertaken performing a comparative analysis of website provider types. Results Overall, there are a considerable number of websites devoted to thoracic surgery: “lung cancer” returned over 150 million websites. About 7.85% (940/11,967) of websites are HON-accredited with differences by search term (P<.001) and tertiles (P<.001) of the first 150 websites, but not between languages. Oncological keywords regarding conditions and procedures were found to return a higher percentage of HON-accreditation. The percentage of HON-accredited sites was similar across all four languages (P=.77). In general, the first tertile contained a higher percentage of HON-accredited sites for every keyword. Conclusions Clinicians should appreciate the lack of validation of the majority of thoracic websites, with discrepancies in quality and number of websites across conditions and procedures. These differences appear similar regardless of language. An opportunity exists for clinicians to participate in the development of informative, ethical, and reliable health websites on the Internet and direct

  11. An assessment of differential reinforcement procedures for learners with autism spectrum disorder.

    PubMed

    Johnson, Kate A; Vladescu, Jason C; Kodak, Tiffany; Sidener, Tina M

    2017-04-01

    Differential reinforcement procedures may promote unprompted correct responding, resulting in a quicker transfer of stimulus control than nondifferential reinforcement. Recent studies that have compared reinforcement arrangements have found that the most effective arrangement may differ across participants. The current study conducted an assessment of differential reinforcement arrangements (i.e., quality, schedule, and magnitude) and nondifferential reinforcement to identify the most effective arrangement for each participant. The assessment phase showed that the quality arrangement was the most efficient for all participants during auditory-visual matching. Next, a validation phase was conducted to evaluate whether the assessment would predict the most effective arrangement across multiple skills. The results from the assessment phase were validated for all participants for the same skill. However, the results were only validated for one participant during the other skills (i.e., tact and intraverbal). The results are discussed in light of previous research and future areas of research. © 2017 Society for the Experimental Analysis of Behavior.

  12. Using Data Mining for Wine Quality Assessment

    NASA Astrophysics Data System (ADS)

    Cortez, Paulo; Teixeira, Juliana; Cerdeira, António; Almeida, Fernando; Matos, Telmo; Reis, José

    Certification and quality assessment are crucial issues within the wine industry. Currently, wine quality is mostly assessed by physicochemical (e.g alcohol levels) and sensory (e.g. human expert evaluation) tests. In this paper, we propose a data mining approach to predict wine preferences that is based on easily available analytical tests at the certification step. A large dataset is considered with white vinho verde samples from the Minho region of Portugal. Wine quality is modeled under a regression approach, which preserves the order of the grades. Explanatory knowledge is given in terms of a sensitivity analysis, which measures the response changes when a given input variable is varied through its domain. Three regression techniques were applied, under a computationally efficient procedure that performs simultaneous variable and model selection and that is guided by the sensitivity analysis. The support vector machine achieved promising results, outperforming the multiple regression and neural network methods. Such model is useful for understanding how physicochemical tests affect the sensory preferences. Moreover, it can support the wine expert evaluations and ultimately improve the production.

  13. Web Service for Positional Quality Assessment: the Wps Tier

    NASA Astrophysics Data System (ADS)

    Xavier, E. M. A.; Ariza-López, F. J.; Ureña-Cámara, M. A.

    2015-08-01

    In the field of spatial data every day we have more and more information available, but we still have little or very little information about the quality of spatial data. We consider that the automation of the spatial data quality assessment is a true need for the geomatic sector, and that automation is possible by means of web processing services (WPS), and the application of specific assessment procedures. In this paper we propose and develop a WPS tier centered on the automation of the positional quality assessment. An experiment using the NSSDA positional accuracy method is presented. The experiment involves the uploading by the client of two datasets (reference and evaluation data). The processing is to determine homologous pairs of points (by distance) and calculate the value of positional accuracy under the NSSDA standard. The process generates a small report that is sent to the client. From our experiment, we reached some conclusions on the advantages and disadvantages of WPSs when applied to the automation of spatial data accuracy assessments.

  14. Pesticide-sampling equipment, sample-collection and processing procedures, and water-quality data at Chicod Creek, North Carolina, 1992

    USGS Publications Warehouse

    Manning, T.K.; Smith, K.E.; Wood, C.D.; Williams, J.B.

    1994-01-01

    Water-quality samples were collected from Chicod Creek in the Coastal Plain Province of North Carolina during the summer of 1992 as part of the U.S. Geological Survey's National Water-Quality Assessment Program. Chicod Creek is in the Albemarle-Pamlico drainage area, one of four study units designated to test equipment and procedures for collecting and processing samples for the solid-phase extraction of selected pesticides, The equipment and procedures were used to isolate 47 pesticides, including organonitrogen, carbamate, organochlorine, organophosphate, and other compounds, targeted to be analyzed by gas chromatography/mass spectrometry. Sample-collection and processing equipment equipment cleaning and set-up procedures, methods pertaining to collecting, splitting, and solid-phase extraction of samples, and water-quality data resulting from the field test are presented in this report Most problems encountered during this intensive sampling exercise were operational difficulties relating to equipment used to process samples.

  15. Revised Methods for Characterizing Stream Habitat in the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Fitzpatrick, Faith A.; Waite, Ian R.; D'Arconte, Patricia J.; Meador, Michael R.; Maupin, Molly A.; Gurtz, Martin E.

    1998-01-01

    Stream habitat is characterized in the U.S. Geological Survey's National Water-Quality Assessment (NAWQA) Program as part of an integrated physical, chemical, and biological assessment of the Nation's water quality. The goal of stream habitat characterization is to relate habitat to other physical, chemical, and biological factors that describe water-quality conditions. To accomplish this goal, environmental settings are described at sites selected for water-quality assessment. In addition, spatial and temporal patterns in habitat are examined at local, regional, and national scales. This habitat protocol contains updated methods for evaluating habitat in NAWQA Study Units. Revisions are based on lessons learned after 6 years of applying the original NAWQA habitat protocol to NAWQA Study Unit ecological surveys. Similar to the original protocol, these revised methods for evaluating stream habitat are based on a spatially hierarchical framework that incorporates habitat data at basin, segment, reach, and microhabitat scales. This framework provides a basis for national consistency in collection techniques while allowing flexibility in habitat assessment within individual Study Units. Procedures are described for collecting habitat data at basin and segment scales; these procedures include use of geographic information system data bases, topographic maps, and aerial photographs. Data collected at the reach scale include channel, bank, and riparian characteristics.

  16. Field guide for collecting and processing stream-water samples for the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Shelton, Larry R.

    1994-01-01

    The U.S. Geological Survey's National Water-Quality Assessment program includes extensive data- collection efforts to assess the quality of the Nations's streams. These studies require analyses of stream samples for major ions, nutrients, sediments, and organic contaminants. For the information to be comparable among studies in different parts of the Nation, consistent procedures specifically designed to produce uncontaminated samples for trace analysis in the laboratory are critical. This field guide describes the standard procedures for collecting and processing samples for major ions, nutrients, organic contaminants, sediment, and field analyses of conductivity, pH, alkalinity, and dissolved oxygen. Samples are collected and processed using modified and newly designed equipment made of Teflon to avoid contamination, including nonmetallic samplers (D-77 and DH-81) and a Teflon sample splitter. Field solid-phase extraction procedures developed to process samples for organic constituent analyses produce an extracted sample with stabilized compounds for more accurate results. Improvements to standard operational procedures include the use of processing chambers and capsule filtering systems. A modified collecting and processing procedure for organic carbon is designed to avoid contamination from equipment cleaned with methanol. Quality assurance is maintained by strict collecting and processing procedures, replicate sampling, equipment blank samples, and a rigid cleaning procedure using detergent, hydrochloric acid, and methanol.

  17. Self-assessment procedure using fuzzy sets

    NASA Astrophysics Data System (ADS)

    Mimi, Fotini

    2000-10-01

    Self-Assessment processes, initiated by a company itself and carried out by its own people, are considered to be the starting point for a regular strategic or operative planning process to ensure a continuous quality improvement. Their importance has increased by the growing relevance and acceptance of international quality awards such as the Malcolm Baldrige National Quality Award, the European Quality Award and the Deming Prize. Especially award winners use the instrument of a systematic and regular Self-Assessment and not only because they have to verify their quality and business results for at least three years. The Total Quality Model of the European Foundation for Quality Management (EFQM), used for the European Quality Award, is the basis for Self-Assessment in Europe. This paper presents a self-assessment supporting method based on a methodology of fuzzy control systems providing an effective means of converting the linguistic approximation into an automatic control strategy. In particular, the elements of the Quality Model mentioned above are interpreted as linguistic variables. The LR-type of a fuzzy interval is used for their representation. The input data has a qualitative character based on empirical investigation and expert knowledge and therefore the base- variables are ordinal scaled. The aggregation process takes place on the basis of a hierarchical structure. Finally, in order to render the use of the method more practical a software system on PC basis is developed and implemented.

  18. Modeling procedures for handling qualities evaluation of flexible aircraft

    NASA Technical Reports Server (NTRS)

    Govindaraj, K. S.; Eulrich, B. J.; Chalk, C. R.

    1981-01-01

    This paper presents simplified modeling procedures to evaluate the impact of flexible modes and the unsteady aerodynamic effects on the handling qualities of Supersonic Cruise Aircraft (SCR). The modeling procedures involve obtaining reduced order transfer function models of SCR vehicles, including the important flexible mode responses and unsteady aerodynamic effects, and conversion of the transfer function models to time domain equations for use in simulations. The use of the modeling procedures is illustrated by a simple example.

  19. A Quality Process Approach to Electronic System Reliability: Supplier Quality Assessment Procedure. Volume 2

    DTIC Science & Technology

    1993-11-01

    AND SUPPORT SERVICE QUALITY ....... 16 3.5.7 SUPPLIER QUALITY ............................................................................. 16 3.6...RESULTS ......................................................................................................... 16 3.6.1 PRODUCT AND SERVICE QUALITY RESULTS...10 5.6 Business Process and Support Service Quality 20 5.7 Supplier Quality 20 6.0 Results 180 6.1 Product and Service Quality Results 90 6.2 Business

  20. Quality control of colonoscopy procedures: a prospective validated method for the evaluation of professional practices applicable to all endoscopic units.

    PubMed

    Coriat, R; Pommaret, E; Chryssostalis, A; Viennot, S; Gaudric, M; Brezault, C; Lamarque, D; Roche, H; Verdier, D; Parlier, D; Prat, F; Chaussade, S

    2009-02-01

    To produce valid information, an evaluation of professional practices has to assess the quality of all practices before, during and after the procedure under study. Several auditing techniques have been proposed for colonoscopy. The purpose of this work is to describe a straightforward original validated method for the prospective evaluation of professional practices in the field of colonoscopy applicable in all endoscopy units without increasing the staff work load. Pertinent quality-control criteria (14 items) were identified by the endoscopists at the Cochin Hospital and were compatible with: findings in the available literature; guidelines proposed by the Superior Health Authority; and application in any endoscopy unit. Prospective routine data were collected and the methodology validated by evaluating 50 colonoscopies every quarter for one year. The relevance of the criteria was assessed using data collected during four separate periods. The standard checklist was complete for 57% of the colonoscopy procedures. The colonoscopy procedure was appropriate according to national guidelines in 94% of cases. These observations were particularly noteworthy: the quality of the colonic preparation was insufficient for 9% of the procedures; complete colonoscopy was achieved for 93% of patients; and 0.38 adenomas and 0.045 carcinomas were identified per colonoscopy. This simple and reproducible method can be used for valid quality-control audits in all endoscopy units. In France, unit-wide application of this method enables endoscopists to validate 100 of the 250 points required for continuous medical training. This is a quality-control tool that can be applied annually, using a random month to evaluate any changes in routine practices.

  1. Procedural justice and quality of life in compensation processes.

    PubMed

    Elbers, Nieke A; Akkermans, Arno J; Cuijpers, Pim; Bruinvels, David J

    2013-11-01

    There is considerable evidence that being involved in compensation processes has a negative impact on claimants' health. Previous studies suggested that this negative effect is caused by a stressful compensation process: claimants suffered from a lack of communication, a lack of information, and feelings of distrust. However, these rather qualitative findings have not been quantitatively investigated yet. This observational study aimed to fill this gap of knowledge, investigating the claimants' perceived fairness of the compensation process, the provided information, and the interaction with lawyers and insurance companies, in relation to the claimants' quality of life. Participants were individuals injured in traffic accidents, older than 18 years, who were involved in a compensation process in the Netherlands. They were recruited by three claims settlement offices. Outcome measures were procedural, interactional, and informational justice, and quality of life. Participants (n=176) perceived the interaction with lawyers to be fairer than the interaction with insurance companies (p<.001). The length of hospital stay was positively associated with procedural justice (β=.31, p<.001). Having trunk/back injury was negatively related to procedural justice (β=-.25, p=.001). Whiplash injury and length of time involved in the claim process were not associated with any of the justice scales. Finally, procedural justice was found to be positively correlated with quality of life (rs=.22, p=.004). The finding that the interaction with insurance companies was considered less fair than the interaction with lawyers may imply that insurers could improve their interaction with claimants, e.g. by communicating more directly. The result that claimants with mild injuries and with trunk/back injuries considered the compensation process to be less fair than those with respectively severe injuries and injuries to other body parts suggests that especially the former two require an

  2. Category 1 external quality assessment program for serum creatinine.

    PubMed

    González-Lao, Elisabet; Díaz-Garzón, Jorge; Corte, Zoraida; Ricós, Carmen; Perich, Carmen; Álvarez, Virtudes; Simón, Margarita; Minchinela, Joana; García-Lario, José Vicente; Boned, Beatriz; Biosca, Carmen; Cava, Fernando; Fernández-Fernández, Pilar; Fernández-Calle, Pilar

    2017-03-01

    The Commission of Analytical Quality and the Committee of External Quality Programs of Spanish Society of Laboratory Medicine (SEQC) in collaboration with the Dutch Foundation for the Quality organized the first national category 1 External Quality Assessment Programs (EQAP) pilot study. The aim is to evaluate the standardization of serum creatinine measurements in the Spanish laboratories through a category 1 external quality assurance program with commutable material and reference method assigned values. A total of 87 Spanish laboratories were involved in this program in 2015. Each day a sample control was measured by duplicate during 6 consecutive days. Percentage deviations and coefficients of variation obtained were compared with quality specifications derived from biological variation. A total of 1044 creatinine results were obtained. Laboratories were coded in 11 different method-traceability combinations. Only enzymatic methods get all results within the acceptability limits. To participate in a category 1 EQAP is a valuable tool to assess the standardization degree in our country; a big effort should be made to promote laboratories to change their procedures and to use enzymatic creatinine methods, in order to achieve a satisfactory standardization degree for this important analyte.

  3. The relationship between competition and quality in procedural cardiac care.

    PubMed

    Glick, David B; Wroblewski, Kristen; Apfelbaum, Sean; Dauber, Benjamin; Woo, Joyce; Tung, Avery

    2015-01-01

    Anesthesiologists are frequently involved in efforts to meet perioperative quality metrics. The degree to which hospitals compete on publicly reported quality measures, however, is unclear. We hypothesized that hospitals in more competitive environments would be more likely to compete on quality and thus perform better on such measures. To test our hypothesis, we studied the relationship between competition and quality in hospitals providing procedural cardiac care and participating in a national quality database. For hospitals performing heart valve surgery (HVS) and delivering acute myocardial infarction (AMI) care in the Hospital Compare database, we assessed the degree of intrahospital competition using both geographical radius and federally defined metropolitan statistical area (MSA) to determine the degree of intrahospital competition. For each hospital, we then correlated the degree of competition with quality measure performance, mortality, patient volume, and per-patient Medicare costs for both HVS and AMI. Six hundred fifty-three hospitals met inclusion criteria for HVS and 1898 hospitals for AMI care. We found that for both definitions of competition, hospitals facing greater competition did not demonstrate better quality measure performance for either HVS or AMI. For both diagnoses, competition by number of hospitals correlated positively with cost: partial correlation coefficients = 0.40 (0.42 for MSA) (P < 0.001) for HVS and 0.52 (0.47 for MSA) (P < 0.001) for AMI. An analysis of the Hospital Compare database found that competition among hospitals correlated overall with increased Medicare costs but did not predict better scores on publicly reported quality metrics. Our results suggest that hospitals do not compete meaningfully on publicly reported quality metrics or costs.

  4. Thoracic Surgery Information on the Internet: A Multilingual Quality Assessment.

    PubMed

    Davaris, Myles; Barnett, Stephen; Abouassaly, Robert; Lawrentschuk, Nathan

    2017-05-12

    Previous data suggest that quality of Internet information regarding surgical conditions and their treatments is variable. However, no comprehensive analysis of website quality exists for thoracic surgery. The aim of this study was to quantify website quality in a multilingual setting using an international standard for assessment. Health On the Net (HON) principles may be applied to websites using an automated toolbar function. We used the English, French, Spanish, and German Google search engines to identify 12,000 websites using keywords related to thoracic conditions and procedures. The first 150 websites returned by each keyword in each language were examined. We compared website quality to assess for tertile (is the quality better in first, second, or third 50 websites returned) and language differences. A further analysis of the English site types was undertaken performing a comparative analysis of website provider types. Overall, there are a considerable number of websites devoted to thoracic surgery: "lung cancer" returned over 150 million websites. About 7.85% (940/11,967) of websites are HON-accredited with differences by search term (P<.001) and tertiles (P<.001) of the first 150 websites, but not between languages. Oncological keywords regarding conditions and procedures were found to return a higher percentage of HON-accreditation. The percentage of HON-accredited sites was similar across all four languages (P=.77). In general, the first tertile contained a higher percentage of HON-accredited sites for every keyword. Clinicians should appreciate the lack of validation of the majority of thoracic websites, with discrepancies in quality and number of websites across conditions and procedures. These differences appear similar regardless of language. An opportunity exists for clinicians to participate in the development of informative, ethical, and reliable health websites on the Internet and direct patients to them. ©Myles Davaris, Stephen Barnett

  5. Analytical procedure validation and the quality by design paradigm.

    PubMed

    Rozet, Eric; Lebrun, Pierre; Michiels, Jean-François; Sondag, Perceval; Scherder, Tara; Boulanger, Bruno

    2015-01-01

    Since the adoption of the ICH Q8 document concerning the development of pharmaceutical processes following a quality by design (QbD) approach, there have been many discussions on the opportunity for analytical procedure developments to follow a similar approach. While development and optimization of analytical procedure following QbD principles have been largely discussed and described, the place of analytical procedure validation in this framework has not been clarified. This article aims at showing that analytical procedure validation is fully integrated into the QbD paradigm and is an essential step in developing analytical procedures that are effectively fit for purpose. Adequate statistical methodologies have also their role to play: such as design of experiments, statistical modeling, and probabilistic statements. The outcome of analytical procedure validation is also an analytical procedure design space, and from it, control strategy can be set.

  6. Comparability of river quality assessment using macrophytes: a multi-step procedure to overcome biogeographical differences.

    PubMed

    Aguiar, F C; Segurado, P; Urbanič, G; Cambra, J; Chauvin, C; Ciadamidaro, S; Dörflinger, G; Ferreira, J; Germ, M; Manolaki, P; Minciardi, M R; Munné, A; Papastergiadou, E; Ferreira, M T

    2014-04-01

    This paper exposes a new methodological approach to solve the problem of intercalibrating river quality national methods when a common metric is lacking and most of the countries share the same Water Framework Directive (WFD) assessment method. We provide recommendations for similar works in future concerning the assessment of ecological accuracy and highlight the importance of a good common ground to make feasible the scientific work beyond the intercalibration. The approach herein presented was applied to highly seasonal rivers of the Mediterranean Geographical Intercalibration Group for the Biological Quality Element Macrophytes. The Mediterranean Group of river macrophytes involved seven countries and two assessment methods with similar acquisition data and assessment concept: the Macrophyte Biological Index for Rivers (IBMR) for Cyprus, France, Greece, Italy, Portugal and Spain, and the River Macrophyte Index (RMI) for Slovenia. Database included 318 sites of which 78 were considered as benchmarks. The boundary harmonization was performed for common WFD-assessment methods (all countries except Slovenia) using the median of the Good/Moderate and High/Good boundaries of all countries. Then, whenever possible, the Slovenian method, RMI was computed for the entire database. The IBMR was also computed for the Slovenian sites and was regressed against RMI in order to check the relatedness of methods (R(2)=0.45; p<0.00001) and to convert RMI boundaries into the IBMR scale. The boundary bias of RMI was computed using direct comparison of classification and the median boundary values following boundary harmonization. The average absolute class differences after harmonization is 26% and the percentage of classifications differing by half of a quality class is also small (16.4%). This multi-step approach to the intercalibration was endorsed by the WFD Regulatory Committee. © 2013 Elsevier B.V. All rights reserved.

  7. Quality assessment of SPR sensor chips; case study on L1 chips.

    PubMed

    Olaru, Andreea; Gheorghiu, Mihaela; David, Sorin; Polonschii, Cristina; Gheorghiu, Eugen

    2013-07-15

    Surface quality of the Surface Plasmon Resonance (SPR) chips is a major limiting issue in most SPR analyses, even more for supported lipid membranes experiments, where both the organization of the lipid matrix and the subsequent incorporation of the target molecule depend on the surface quality. A novel quantitative method to characterize the quality of SPR sensors chips is described for L1 chips subject to formation of lipid films, injection of membrane disrupting compounds, followed by appropriate regeneration procedures. The method consists in analysis of the SPR reflectivity curves for several standard solutions (e.g. PBS, HEPES or deionized water). This analysis reveals the decline of sensor surface as a function of the number of experimental cycles (consisting in biosensing assay and regeneration step) and enables active control of surface regeneration for enhanced reproducibility. We demonstrate that quantitative evaluation of the changes in reflectivity curves (shape of the SPR dip) and of the slope of the calibration curve provides a rapid and effective procedure for surface quality assessment. Whereas the method was tested on L1 SPR sensors chips, we stress on its amenability to assess the quality of other types of SPR chips, as well. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. TU-FG-201-12: Designing a Risk-Based Quality Assurance Program for a Newly Implemented Y-90 Microspheres Procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vile, D; Zhang, L; Cuttino, L

    2016-06-15

    Purpose: To create a quality assurance program based upon a risk-based assessment of a newly implemented SirSpheres Y-90 procedure. Methods: A process map was created for a newly implemented SirSpheres procedure at a community hospital. The process map documented each step of this collaborative procedure, as well as the roles and responsibilities of each member. From the process map, different potential failure modes were determined as well as any current controls in place. From this list, a full failure mode and effects analysis (FMEA) was performed by grading each failure mode’s likelihood of occurrence, likelihood of detection, and potential severity.more » These numbers were then multiplied to compute the risk priority number (RPN) for each potential failure mode. Failure modes were then ranked based on their RPN. Additional controls were then added, with failure modes corresponding to the highest RPNs taking priority. Results: A process map was created that succinctly outlined each step in the SirSpheres procedure in its current implementation. From this, 72 potential failure modes were identified and ranked according to their associated RPN. Quality assurance controls and safety barriers were then added for failure modes associated with the highest risk being addressed first. Conclusion: A quality assurance program was created from a risk-based assessment of the SirSpheres process. Process mapping and FMEA were effective in identifying potential high-risk failure modes for this new procedure, which were prioritized for new quality assurance controls. TG 100 recommends the fault tree analysis methodology to design a comprehensive and effective QC/QM program, yet we found that by simply introducing additional safety barriers to address high RPN failure modes makes the whole process simpler and safer.« less

  9. Longitudinal trends with improvement in quality of life after TVT, TVT O and Burch colposuspension procedures.

    PubMed

    Drahoradova, Petra; Martan, Alois; Svabik, Kamil; Zvara, Karel; Otava, Martin; Masata, Jaromir

    2011-02-01

    Comparison of the quality of life (QoL) trends after TVT, TVT O and Burch colposuspension (BCS) procedures and comparison of long-term subjective and objective outcomes. The study included 215 women who underwent a TVT, TVT O or BCS procedure. We monitored QoL after each procedure and the effect of complications on the QoL as assessed by the IQOL questionnaire over a 3-year period. The study was completed by 74.5% of women after TVT, 74.5% after TVT O, and 65.2% after BCS procedure. In the long-term, the QoL improved from 46.9 to 88.7 and remained stable after BCS; after TVT and TVT O, it declined, but only after TVT O was the decline statistically significant compared to BCS. The IQOL for women with post-operative complications has a clear descending tendency. The effect of the complications is highly significant (p<0.001). Only the OAB complication had a statistically significant effect on QoL p<0.001. Preexistent OAB does not negatively affect postoperative results of anti-incontinence surgery. There was a statistically significant decline with the longitudinal values of IQOL with TVT O, but not with TVT or BCS. Anti-incontinence operations significantly improve quality of life for women with MI, but compared to the SI group, the quality of life is worse when measured at a longer time interval after the operation. Anti-incontinence operations significantly improve quality of life, and the difference in preoperative status in the long-term follow-up is demonstrable.

  10. An Automated Inpatient Split-dose Bowel Preparation System Improves Colonoscopy Quality and Reduces Repeat Procedures.

    PubMed

    Yadlapati, Rena; Johnston, Elyse R; Gluskin, Adam B; Gregory, Dyanna L; Cyrus, Rachel; Werth, Lindsay; Ciolino, Jody D; Grande, David P; Keswani, Rajesh N

    2017-07-19

    Inpatient colonoscopy preparations are often inadequate, compromising patient safety and procedure quality, while resulting in greater hospital costs. The aims of this study were to: (1) design and implement an electronic inpatient split-dose bowel preparation order set; (2) assess the intervention's impact upon preparation adequacy, repeated colonoscopies, hospital days, and costs. We conducted a single center prospective pragmatic quasiexperimental study of hospitalized adults undergoing colonoscopy. The experimental intervention was designed using DMAIC (define, measure, analyze, improve, and control) methodology. Prospective data collected over 12 months were compared with data from a historical preintervention cohort. The primary outcome was bowel preparation quality and secondary outcomes included number of repeated procedures, hospital days, and costs. On the basis of a Delphi method and DMAIC process, we created an electronic inpatient bowel preparation order set inclusive of a split-dose bowel preparation algorithm, automated orders for rescue medications, and nursing bowel preparation checks. The analysis data set included 969 patients, 445 (46%) in the postintervention group. The adequacy of bowel preparation significantly increased following intervention (86% vs. 43%; P<0.01) and proportion of repeated procedures decreased (2.0% vs. 4.6%; P=0.03). Mean hospital days from bowel preparation initiation to discharge decreased from 8.0 to 6.9 days (P=0.02). The intervention resulted in an estimated 1-year cost-savings of $46,076 based on a reduction in excess hospital days associated with repeated and delayed procedures. Our interdisciplinary initiative targeting inpatient colonoscopy preparations significantly improved quality and reduced repeat procedures, and hospital days. Other institutions should consider utilizing this framework to improve inpatient colonoscopy value.

  11. Quality assurance: Importance of systems and standard operating procedures

    PubMed Central

    Manghani, Kishu

    2011-01-01

    It is mandatory for sponsors of clinical trials and contract research organizations alike to establish, manage and monitor their quality control and quality assurance systems and their integral standard operating procedures and other quality documents to provide high-quality products and services to fully satisfy customer needs and expectations. Quality control and quality assurance systems together constitute the key quality systems. Quality control and quality assurance are parts of quality management. Quality control is focused on fulfilling quality requirements, whereas quality assurance is focused on providing confidence that quality requirements are fulfilled. The quality systems must be commensurate with the Company business objectives and business model. Top management commitment and its active involvement are critical in order to ensure at all times the adequacy, suitability, effectiveness and efficiency of the quality systems. Effective and efficient quality systems can promote timely registration of drugs by eliminating waste and the need for rework with overall financial and social benefits to the Company. PMID:21584180

  12. Quality assurance: Importance of systems and standard operating procedures.

    PubMed

    Manghani, Kishu

    2011-01-01

    It is mandatory for sponsors of clinical trials and contract research organizations alike to establish, manage and monitor their quality control and quality assurance systems and their integral standard operating procedures and other quality documents to provide high-quality products and services to fully satisfy customer needs and expectations. Quality control and quality assurance systems together constitute the key quality systems. Quality control and quality assurance are parts of quality management. Quality control is focused on fulfilling quality requirements, whereas quality assurance is focused on providing confidence that quality requirements are fulfilled. The quality systems must be commensurate with the Company business objectives and business model. Top management commitment and its active involvement are critical in order to ensure at all times the adequacy, suitability, effectiveness and efficiency of the quality systems. Effective and efficient quality systems can promote timely registration of drugs by eliminating waste and the need for rework with overall financial and social benefits to the Company.

  13. Quality of health care and the need for assessment.

    PubMed

    Bosse, G; Ngoli, B; Leshabari, M T; Külker, R; Dämmrich, T; Abels, W; Breuer, J P; Kersten, R; Spies, C

    2011-09-01

    In many hospitals of developing countries quality of care is below the expected standard to maintain patient safety. In 2006, health care experts from Tanzania and Germany collaborated on a set of indicators to be used as a hospital performance assessment tool. The aim of this study was to introduce this tool and check its feasibility for use in a Tanzanian regional hospital. Within the hospital, independent observers assessed quantitatively structural quality and the performance of health care encounter using an itemized scale from 0 (0%) to 2 (100%) for each defined item. Outcome parameters were taken from the annual hospital report. In addition, semi-qualitative interviews with staff and patients were held to a) assess staff knowledge of the treatment guidelines published by the Tanzanian Ministry of Health and Social Welfare (MoHSW), b) assess attitudes and user motivation and c) authenticate the quantitative findings in a mixed-method triangulation approach. Structural quality in maternity was at 75% of the expected standard, while process quality ranged from 36% (Care of the newborn with APGAR score < 4) to 47% (normal delivery procedure). Staff knowledge ranged between 64% and 87% with low motivation and commitment given as contributing factors. Outcome (maternal mortality) was 481/100,000 live births with an infant mortality rate of 10%. The tool appeared to be feasible and effective in judging care quality. It provides a model for continuous quality improvement. Motivation of health care workers, a strong determinant of care process quality, might be improved by strengthening internal factors in health facilities. For conclusive validation, further studies using the tool must be conducted with larger numbers of institutions.

  14. Assessment of procedural skills in residents working in a research and training institute: An effort to ensure patient safety and quality control.

    PubMed

    Kumari, Kamlesh; Samra, Tanvir; Naik, B Naveen; Saini, Vikas

    2018-01-01

    To ensure patient safety, it is important to regularly assess the knowledge and practical skills of anesthesia trainees. This study was conducted to evaluate the competency of the residents and the impact of various corrective measures in the form of didactic lectures and clinical skill demonstrations on the conduct of various procedural skills by the residents. Ninety-five junior residents were enrolled in this study. Assessment of competency of 1 st , 2 nd , and 3 rd year residents in performing various procedure skills of anesthesia was done in two stages using procedure specific checklist (PSC) and Global Rating Scales (GRSs). Preliminary results of the first assessment (Score 1) were discussed with the residents; deficiencies were identified and corrective measures suggested by didactic lectures and clinical skill demonstrations which were followed by a subsequent assessment after 3 months (Score 2). There was a statistically significant improvement in the PSC and GRS scores after corrective measures for all the procedural interventions studied. Percentage increase in scores was maximum in 1 st year (42.98 ± 6.62) followed by 2 nd year (34.62 ± 5.49) and minimum in 3 rd year residents (18.06 ± 3.69). The percentage increase of scores was almost similar for all subset of procedural skills; low, intermediate, and high skill anesthetic procedures. For assessment of procedural skills of residents, use of PSC and GRS scores should be incorporated and the same should be used to monitor the impact of various corrective measures (didactic lectures and clinical skill demonstrations) on the conduct of various procedural skills by the resident.

  15. An inter-laboratory comparison study of image quality of PET scanners using the NEMA NU 2-2001 procedure for assessment of image quality

    NASA Astrophysics Data System (ADS)

    Bergmann, Helmar; Dobrozemsky, Georg; Minear, Gregory; Nicoletti, Rudolf; Samal, Martin

    2005-05-01

    An inter-laboratory comparison study was conducted to assess the image quality of PET scanners in Austria. The survey included both dedicated PET scanners (D-PET, n = 8) and coincidence cameras (GC-PET, n = 7). Measurement of image quality was based on the NEMA (National Electrical Manufacturers Association) NU 2-2001 protocol and the IEC (International Electrotechnical Commission) body phantom. The latter contains six fillable spheres ranging in diameter from 37 mm down to 10 mm and a 'lung' insert. The two largest lesions L1-2 simulate cold lesions, the four smaller ones (L3-6) are filled with 18F and activity concentration ratios relative to background of 8:1 and 4:1, respectively. Acquisition and reconstruction in the study employed the participating institutes' standard oncological processing protocol. Calculation of contrast of the spheres was performed with a fully automated procedure. Contrast quality indices (CQIs) reflecting global performance were obtained by summing individual contrast values. Other image quality parameters calculated according to the NEMA protocol were background variability and relative error for correction of attenuation and scatter. Contrast values obtained were 61 ± 16 and 37 ± 14 for L1 (per cent contrast ± SD for D-PET and GC-PET, respectively), 57 ± 16 and 29 ± 16 for L2, 46 ± 10 and 26 ± 6.3 for L3, 37 ± 10 and 15 ± 4.3 for L4, 26 ± 11.5 and 6.1 ± 2.5 for L5, 14 ± 7.1 and 2.6 ± 2.6 for L6, with D-PET systems consistently being superior to GC-PET systems. CQIs permitted ranking of the scanners, also demonstrating a clear distinction between D-PET and GC-PET systems. Background variability was largest for GC-PET systems; the relative error of attenuation and scatter correction was significantly correlated with image quality for D-PET systems only. The study demonstrated considerable differences in image quality not only between GC-PET and D-PET systems but also between individual D-PET systems with possible

  16. An evaluation of periodontal assessment procedures among Indiana dental hygienists.

    PubMed

    Stephan, Christine A

    2014-01-01

    Using a descriptive correlational design, this study surveyed periodontal assessment procedures currently performed by Indiana dental hygienists in general dentistry practices to reveal if deficiencies in assessment exist. Members (n = 354) of the Indiana Dental Hygienists' Association (IDHA) were invited to participate in the survey. A 22 multiple choice question survey, using Likert scales for responses, was open to participants for three weeks. Descriptive and non-parametric inferential statistics analyzed questions related to demographics and assessment procedures practiced. In addition, an evaluation of the awareness of periodontal assessment procedures recommended by the American Academy of Periodontology (AAP) was examined. Of the 354 Indiana dental hygienists surveyed, a 31.9% response rate was achieved. Participants were asked to identify the recommended AAP periodontal assessment procedures they perform. The majority of respondents indicated either frequently or always performing the listed assessment procedures. Additionally, significant relationships were found between demographic factors and participants' awareness and performance of recommended AAP assessment procedures. While information gathered from this study is valuable to the body of literature regarding periodontal disease assessment, continued research with larger survey studies should be conducted to obtain a more accurate national representation of what is being practiced by dental hygienists.

  17. Assessment of CT image quality using a Bayesian approach

    NASA Astrophysics Data System (ADS)

    Reginatto, M.; Anton, M.; Elster, C.

    2017-08-01

    One of the most promising approaches for evaluating CT image quality is task-specific quality assessment. This involves a simplified version of a clinical task, e.g. deciding whether an image belongs to the class of images that contain the signature of a lesion or not. Task-specific quality assessment can be done by model observers, which are mathematical procedures that carry out the classification task. The most widely used figure of merit for CT image quality is the area under the ROC curve (AUC), a quantity which characterizes the performance of a given model observer. In order to estimate AUC from a finite sample of images, different approaches from classical statistics have been suggested. The goal of this paper is to introduce task-specific quality assessment of CT images to metrology and to propose a novel Bayesian estimation of AUC for the channelized Hotelling observer (CHO) applied to the task of detecting a lesion at a known image location. It is assumed that signal-present and signal-absent images follow multivariate normal distributions with the same covariance matrix. The Bayesian approach results in a posterior distribution for the AUC of the CHO which provides in addition a complete characterization of the uncertainty of this figure of merit. The approach is illustrated by its application to both simulated and experimental data.

  18. 49 CFR 1540.205 - Procedures for security threat assessment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... threat; (ii) The basis for the determination; (iii) Information about how the applicant may appeal the... 49 Transportation 9 2010-10-01 2010-10-01 false Procedures for security threat assessment. 1540... SECURITY: GENERAL RULES Security Threat Assessments § 1540.205 Procedures for security threat assessment...

  19. Automated Quality Assessment of Structural Magnetic Resonance Brain Images Based on a Supervised Machine Learning Algorithm.

    PubMed

    Pizarro, Ricardo A; Cheng, Xi; Barnett, Alan; Lemaitre, Herve; Verchinski, Beth A; Goldman, Aaron L; Xiao, Ena; Luo, Qian; Berman, Karen F; Callicott, Joseph H; Weinberger, Daniel R; Mattay, Venkata S

    2016-01-01

    High-resolution three-dimensional magnetic resonance imaging (3D-MRI) is being increasingly used to delineate morphological changes underlying neuropsychiatric disorders. Unfortunately, artifacts frequently compromise the utility of 3D-MRI yielding irreproducible results, from both type I and type II errors. It is therefore critical to screen 3D-MRIs for artifacts before use. Currently, quality assessment involves slice-wise visual inspection of 3D-MRI volumes, a procedure that is both subjective and time consuming. Automating the quality rating of 3D-MRI could improve the efficiency and reproducibility of the procedure. The present study is one of the first efforts to apply a support vector machine (SVM) algorithm in the quality assessment of structural brain images, using global and region of interest (ROI) automated image quality features developed in-house. SVM is a supervised machine-learning algorithm that can predict the category of test datasets based on the knowledge acquired from a learning dataset. The performance (accuracy) of the automated SVM approach was assessed, by comparing the SVM-predicted quality labels to investigator-determined quality labels. The accuracy for classifying 1457 3D-MRI volumes from our database using the SVM approach is around 80%. These results are promising and illustrate the possibility of using SVM as an automated quality assessment tool for 3D-MRI.

  20. Colonoscopy video quality assessment using hidden Markov random fields

    NASA Astrophysics Data System (ADS)

    Park, Sun Young; Sargent, Dusty; Spofford, Inbar; Vosburgh, Kirby

    2011-03-01

    With colonoscopy becoming a common procedure for individuals aged 50 or more who are at risk of developing colorectal cancer (CRC), colon video data is being accumulated at an ever increasing rate. However, the clinically valuable information contained in these videos is not being maximally exploited to improve patient care and accelerate the development of new screening methods. One of the well-known difficulties in colonoscopy video analysis is the abundance of frames with no diagnostic information. Approximately 40% - 50% of the frames in a colonoscopy video are contaminated by noise, acquisition errors, glare, blur, and uneven illumination. Therefore, filtering out low quality frames containing no diagnostic information can significantly improve the efficiency of colonoscopy video analysis. To address this challenge, we present a quality assessment algorithm to detect and remove low quality, uninformative frames. The goal of our algorithm is to discard low quality frames while retaining all diagnostically relevant information. Our algorithm is based on a hidden Markov model (HMM) in combination with two measures of data quality to filter out uninformative frames. Furthermore, we present a two-level framework based on an embedded hidden Markov model (EHHM) to incorporate the proposed quality assessment algorithm into a complete, automated diagnostic image analysis system for colonoscopy video.

  1. Medical faculties educational network: multidimensional quality assessment.

    PubMed

    Komenda, Martin; Schwarz, Daniel; Feberová, Jitka; Stípek, Stanislav; Mihál, Vladimír; Dušek, Ladislav

    2012-12-01

    Today, World Wide Web technology provides many opportunities in the disclosure of electronic learning and teaching content. The MEFANET project (MEdical FAculties NETwork) has initiated international, effective and open cooperation among all Czech and Slovak medical faculties in the medical education fields. This paper introduces the original MEFANET educational web portal platform. Its main aim is to present the unique collaborative environment, which combines the sharing of electronic educational resources with the use tools for their quality evaluation. It is in fact a complex e-publishing system, which consists of ten standalone portal instances and one central gateway. The fundamental principles of the developed system and used technologies are reported here, as well as procedures of a new multidimensional quality assessment. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  2. Weld procedure produces quality welds for thick sections of Hastelloy-X

    NASA Technical Reports Server (NTRS)

    Flens, F. J.; Fletcher, C. W.; Glasier, L. F., Jr.

    1967-01-01

    Welding program produces premium quality, multipass welds in heavy tube sections of Hastelloy-X. It develops semiautomatic tungsten/inert gas procedures, weld wire procurement specifications material weld properties, welder-operator training, and nondestructive testing inspection techniques and procedures.

  3. Longitudinal trends with Improvement in Quality of Life after TVT, TVT O and Burch Colposuspension Procedures

    PubMed Central

    Drahoradova, Petra; Martan, Alois; Svabik, Kamil; Zvara, Karel; Otava, Martin; Masata, Jaromir

    2011-01-01

    Summary Background Comparison of the quality of life (QoL) trends after TVT, TVT O and Burch colposuspension (BCS) procedures and comparison of long-term subjective and objective outcomes. Material/Methods The study included 215 women who underwent a TVT, TVT O or BCS procedure. We monitored QoL after each procedure and the effect of complications on the QoL as assessed by the IQOL questionnaire over a 3-year period. Results The study was completed by 74.5% of women after TVT, 74.5% after TVT O, and 65.2% after BCS procedure. In the long-term, the QoL improved from 46.9 to 88.7 and remained stable after BCS; after TVT and TVT O, it declined, but only after TVT O was the decline statistically significant compared to BCS. The IQOL for women with post-operative complications has a clear descending tendency. The effect of the complications is highly significant (p<0.001). Only the OAB complication had a statistically significant effect on QoL p<0.001. Preexistent OAB does not negatively affect postoperative results of anti-incontinence surgery. Conclusions There was a statistically significant decline with the longitudinal values of IQOL with TVT O, but not with TVT or BCS. Anti-incontinence operations significantly improve quality of life for women with MI, but compared to the SI group, the quality of life is worse when measured at a longer time interval after the operation. Anti-incontinence operations significantly improve quality of life, and the difference in preoperative status in the long-term follow-up is demonstrable. PMID:21278690

  4. Procedures for scour assessments at bridges in Pennsylvania

    USGS Publications Warehouse

    Cinotto, Peter J.; White, Kirk E.

    2000-01-01

    Scour is the process and result of flowing water eroding the bed and banks of a stream. Scour at nearly 14,300 bridges(1) spanning water, and the stability of river and stream channels in Pennsylvania, are being assessed by the U.S. Geological Survey (USGS) in cooperation with the Pennsylvania Department of Transportation (PennDOT). Procedures for bridge-scour assessments have been established to address the needs of PennDOT in meeting a 1988 Federal Highway Administration mandate requiring states to establish a program to assess all public bridges over water for their vulnerability to scour. The procedures also have been established to help develop an understanding of the local and regional factors that affect scour and channel stability. This report describes procedures for the assessment of scour at all bridges that are 20 feet or greater in length that span water in Pennsylvania. There are two basic types of assessment: field-viewed bridge site assessments, for which USGS personnel visit the bridge site, and office-reviewed bridge site assessments, for which USGS personnel compile PennDOT data and do not visit the bridge site. Both types of assessments are primarily focused at assisting PennDOT in meeting the requirements of the Federal Highway Administration mandate; however, both assessments include procedures for the collection and processing of ancillary data for subsequent analysis. Date of bridge construction and the accessibility of the bridge substructure units for inspection determine which type of assessment a bridge receives. A Scour-Critical Bridge Indicator Code and a Scour Assessment Rating are computed from selected collected and compiled data. PennDOT personnel assign the final Scour-Critical Bridge Indicator Code and a Scour Assessment Rating on the basis of their review of all data. (1)Words presented in bold type are defined in the Glossary section of this report.

  5. Quality control and the substantive influence of environmental impact assessment in Finland

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poeloenen, Ismo

    2006-07-15

    This paper focuses on the challenges concerning the quality assurance of environmental impact statements (EIS) in Finland and the European Union. Moreover, the linkage between environmental impact assessment and decision-making is examined from a legal point of view. In addition, the paper includes some comparative remarks concerning the content requirements of examination of alternatives. The study reveals that a significant problem of the Finnish EIA system is the lack of efficient access to a judicial procedure to challenge the quality and completeness of an EIS. Another pitfall is the fact that in certain permit procedures, environmental consideration is so limitedmore » that only a minor part of the EIA can be taken into account. In its current state, EIA legislation in the EU and in Finland does not guarantee that the assessment results filter into decision-making. From the national point of view, the shortcomings can be addressed by amending current legislation concerning licensing procedures so that authorities have the competence and the duty to take environmental matters widely into account in the permit consideration. At the European level, a legislative alternative could be to strengthen the substantive element of the EIA Directive (85/337/EEC). This would increase the weight of EIA related arguments in the national appellate procedures and contribute, in some cases significantly, to the substantive influence of EIA in decision-making.« less

  6. Revisiting the Procedures for the Vector Data Quality Assurance in Practice

    NASA Astrophysics Data System (ADS)

    Erdoğan, M.; Torun, A.; Boyacı, D.

    2012-07-01

    of spatial data quality concepts into developments and application requires existence of conceptual, logical and most importantly physical existence of data model, rules and knowledge of realization in a form of geo-spatial data. The applicable metrics and thresholds are determined on this concrete base. This study discusses application of geo-spatial data quality issues and QA (quality assurance) and QC procedures in the topographic data production. Firstly we introduce MGCP (Multinational Geospatial Co-production Program) data profile of NATO (North Atlantic Treaty Organization) DFDD (DGIWG Feature Data Dictionary), the requirements of data owner, the view of data producers for both data capturing and QC and finally QA to fulfil user needs. Then, our practical and new approach which divides the quality into three phases is introduced. Finally, implementation of our approach to accomplish metrics, measures and thresholds of quality definitions is discussed. In this paper, especially geometry and semantics quality and quality control procedures that can be performed by the producers are discussed. Some applicable best-practices that we experienced on techniques of quality control, defining regulations that define the objectives and data production procedures are given in the final remarks. These quality control procedures should include the visual checks over the source data, captured vector data and printouts, some automatic checks that can be performed by software and some semi-automatic checks by the interaction with quality control personnel. Finally, these quality control procedures should ensure the geometric, semantic, attribution and metadata quality of vector data.

  7. Progressing quality control in environmental impact assessment beyond legislative compliance: An evaluation of the IEMA EIA Quality Mark certification scheme

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bond, Alan, E-mail: alan.bond@uea.ac.uk; Research Unit for Environmental Sciences and Management, North-West University; Fischer, Thomas B, E-mail: fischer@liverpool.ac.uk

    The effectiveness of Environmental Impact Assessment (EIA) systems is contingent on a number of control mechanisms: procedural; judicial; evaluative; public and government agency; professional; and development aid agency. If we assume that procedural and judicial controls are guaranteed in developed EIA systems, then progressing effectiveness towards an acceptable level depends on improving the performance of other control mechanisms over time. These other control mechanisms are either absent, or are typically centrally controlled, requiring public finances; this we argue is an unpopular model in times of greater Government austerity. Here we evaluate a market-based mechanism for improving the performance of evaluativemore » and professional control mechanisms, the UK Institute of Environmental Management and Assessments' EIA Quality Mark. We do this by defining dimensions of effectiveness for the purposes of our evaluation, and by identifying international examples of the approaches taken to delivering the other control measures to validate the approach taken in the EIA Quality Mark. We then evaluate the EIA Quality Mark, when used in combination with legal procedures and an active judiciary, against the effectiveness dimensions and use time-series analysis of registrant data to examine its ability to progress practice. We conclude that the EIA Quality Mark has merit as a model for a market-based mechanism, and may prove a more financially palatable approach for delivering effective EIA in mature systems in countries that lack centralised agency oversight. It may, therefore, be of particular interest to some Member States of the European Union for ensuring forthcoming certification requirements stemming from recent amendments to the EIA Directive. - Highlights: • Quality control mechanisms in EIA are identified. • Effectiveness of EIA is conceptualised for evaluation purposes. • The UK IEMA EIA Quality Mark is introduced as a market-based mechanism.

  8. Avoiding Assessment Anarchy. Quality Test Administration Strategies: Communicate Expectations, Reduce Variation, Increase Quality, Improve Relationships, Reward Excellence, Recognize Success.

    ERIC Educational Resources Information Center

    Matter, M. Kevin

    This paper presents strategies that address the needs of the school district assessment office for standardized procedures to support reliable and efficient test processing and reporting and that meet the needs of school staff for test administration guidelines. The key to test administration and processing quality is a knowledgeable test…

  9. Procedures and methods of benefit assessments for medicines in Germany.

    PubMed

    Bekkering, Geertruida E; Kleijnen, Jos

    2008-11-01

    The Federal Joint Committee (FJC; Gemeinsamer Bundesausschuss, G-BA) defines the health-care elements that are to be reimbursed by sickness funds. To define a directive, the FJC can commission benefit assessments, which provide an overview of the scientific evidence regarding the efficacy and benefits of an intervention. This paper describes the operational implementation of the legal requirements with regard to the benefit assessments of medicines. Such benefit assessments are sometimes referred to as "isolated benefit assessments," to distinguish them from benefit assessments as part of a full economic evaluation.The FJC has the freedom to commission these assessments from any agency; however, to date the majority have commissioned the Institute for Quality and Efficiency in Health Care (IQWiG). Nevertheless, the content of this paper applies integrally to any institute commissioned for such assessments. In this report, 'the institute' is used when the text refers to any of these institutes.The legal framework for benefit assessments is laid out in the German Social Code Book version V ( http://www.sozialgesetzbuch.de ), Sects. 35b ( section 1), 139a ( section 4-6) and Sect. 139b ( section 3). It is specified that: The institute must guarantee high transparency. The institute must provide appropriate participation of relevant parties for the commission-related development of assessments, and opportunity for comment on all important segments of the assessment procedure. The institute has to report on the progress and results of the work at regular intervals. The institute is held to giving the commission to external experts. Based on the legal framework, the institute must guarantee a high procedural transparency. Transparency of the whole process should be achieved, which is evidenced by clear reporting of procedures and criteria in all phases undertaken in the benefit assessment. The most important means of enhancing transparency are: 1. To implement a scoping

  10. [Procedures and methods of benefit assessments for medicines in Germany].

    PubMed

    Bekkering, G E; Kleijnen, J

    2008-12-01

    The Federal Joint Committee (FJC; Gemeinsamer Bundesausschuss, G-BA) defines the health-care elements that are to be reimbursed by sickness funds. To define a directive, the FJC can commission benefit assessments, which provide an overview of the scientific evidence regarding the efficacy and benefits of an intervention. This paper describes the operational implementation of the legal requirements with regard to the benefit assessments of medicines. Such benefit assessments are sometimes referred to as "isolated benefit assessments," to distinguish them from benefit assessments as part of a full economic evaluation. The FJC has the freedom to commission these assessments from any agency; however, to date the majority have commissioned the Institute for Quality and Efficiency in Health Care (IQWiG). Nevertheless, the content of this paper applies integrally to any institute commissioned for such assessments. In this report, "the institute"' is used when the text refers to any of these institutes. The legal framework for benefit assessments is laid out in the German Social Code Book version V (http://www. sozialgesetzbuch.de), Sects. 35b ( section sign 1), 139a ( section sign 4-6) and Sect. 139b ( section sign 3). It is specified that: The institute must guarantee high transparency. The institute must provide appropriate participation of relevant parties for the commission-related development of assessments, and opportunity for comment on all important segments of the assessment procedure. The institute has to report on the progress and results of the work at regular intervals. The institute is held to giving the commission to external experts. Based on the legal framework, the institute must guarantee a high procedural transparency. Transparency of the whole process should be achieved, which is evidenced by clear reporting of procedures and criteria in all phases undertaken in the benefit assessment. The most important means of enhancing transparency are: 1. To

  11. Applicability of ambient toxicity testing to national or regional water-quality assessment

    USGS Publications Warehouse

    Elder, John F.

    1990-01-01

    Comprehensive assessment of the quality of natural waters requires a multifaceted approach. Descriptions of existing conditions may be achieved by various kinds of chemical and hydrologic analyses, whereas information about the effects of such conditions on living organisms depends on biological monitoring. Toxicity testing is one type of biological monitoring that can be used to identify possible effects of toxic contaminants. Based on experimentation designed to monitor responses of organisms to environmental stresses, toxicity testing may have diverse purposes in water-quality assessments. These purposes may include identification of areas that warrant further study because of poor water quality or unusual ecological features, verification of other types of monitoring, or assessment of contaminant effects on aquatic communities. Toxicity-test results are most effective when used as a complement to chemical analyses, hydrologic measurements, and other biological monitoring. However, all toxicity-testing procedures have certain limitations that must be considered in developing the methodology and applications of toxicity testing in any large-scale water-quality-assessment program. A wide variety of toxicity-test methods have been developed to fulfill the needs of diverse applications. The methods differ primarily in the selections made relative to four characteristics: (1) test species, (2) endpoint (acute or chronic), (3) test-enclosure type, and (4) test substance (toxicant) that functions as the environmental stress. Toxicity-test approaches vary in their capacity to meet the needs of large-scale assessments of existing water quality. Ambient testing, whereby the test organism is exposed to naturally occurring substances that contain toxicant mixtures in an organic or inorganic matrix, is more likely to meet these needs than are procedures that call for exposure of the test organisms to known concentrations of a single toxicant. However, meaningful

  12. [Quality of the pharmacotherapeutic recommendations for the integrated care procedures in Andalusia].

    PubMed

    Corte, Rosa María Muñoz; Estepa, Raúl García; Ramos, Bernardo Santos; Paloma, Francisco Javier Bautista

    2009-01-01

    To evaluate the quality of the pharmacotherapeutic recommendations included in the Integrated Care Procedures (PAIs regarding its initials in Spanish) of the Andalusian Ministry of Health, published up to March 2008, through the design and validation of a tool. The assessment tool was designed based on similar instruments, specifically the AGREE. Other criteria included were taken from various literature sources or were devised by ourselves. The tool was validated prior to being used. After applying it to all the PAIs, we examined the degree of compliance with these pharmacotherapeutic criteria, both as a whole and by PAIs subgroups. The developed tool is a questionnaire of 20 items, divided into 4 sections. The first section consists of the essential criteria, and the rest make reference to more specific, non essential criteria: definition of the level of evidence, thoroughness of information and definition of indicators. It was found that 4 of the 60 PAIs do not contain any type of therapeutic recommendation. No PAI fulfils all the items listed in the tool, however, 70 % of them fulfil the essential quality criteria established. There is a great variability in the content of pharmacotherapeutic recommendations for each PAI. Once the validity of the tool has been proved, it could be used to assess the quality of the therapeutic recommendations in clinical practice guidelines.

  13. [Study on procedure of seed quality testing and seed grading scale of Phellodendron amurense].

    PubMed

    Liu, Yanlu; Zhang, Zhao; Dai, Lingchao; Zhang, Bengang; Zhang, Xiaoling; Wang, Han

    2011-12-01

    To study the procedure of seed quality testing and seed grading scale of Phellodendron amurense. Seed quality testing methods were developed, which included the test of sampling, seed purity, weight per 1 000 seeds, seed moisture, seed viability and germination rate. The related data from 62 cases of seed specimens of P. amurense were analyzed by cluster analysis. The seed quality test procedure was developed, and the seed quality grading scale was formulated.

  14. Quality assessment of protein model-structures using evolutionary conservation.

    PubMed

    Kalman, Matan; Ben-Tal, Nir

    2010-05-15

    Programs that evaluate the quality of a protein structural model are important both for validating the structure determination procedure and for guiding the model-building process. Such programs are based on properties of native structures that are generally not expected for faulty models. One such property, which is rarely used for automatic structure quality assessment, is the tendency for conserved residues to be located at the structural core and for variable residues to be located at the surface. We present ConQuass, a novel quality assessment program based on the consistency between the model structure and the protein's conservation pattern. We show that it can identify problematic structural models, and that the scores it assigns to the server models in CASP8 correlate with the similarity of the models to the native structure. We also show that when the conservation information is reliable, the method's performance is comparable and complementary to that of the other single-structure quality assessment methods that participated in CASP8 and that do not use additional structural information from homologs. A perl implementation of the method, as well as the various perl and R scripts used for the analysis are available at http://bental.tau.ac.il/ConQuass/. nirb@tauex.tau.ac.il Supplementary data are available at Bioinformatics online.

  15. An evaluation of the quality of obstetric morbidity coding using an objective assessment tool, the Performance Indicators For Coding Quality (PICQ).

    PubMed

    Lamb, Mary K; Innes, Kerry; Saad, Patricia; Rust, Julie; Dimitropoulos, Vera; Cumerlato, Megan

    The Performance Indicators for Coding Quality (PICQ) is a data quality assessment tool developed by Australia's National Centre for Classification in Health (NCCH). PICQ consists of a number of indicators covering all ICD-10-AM disease chapters, some procedure chapters from the Australian Classification of Health Intervention (ACHI) and some Australian Coding Standards (ACS). The indicators can be used to assess the coding quality of hospital morbidity data by monitoring compliance of coding conventions and ACS; this enables the identification of particular records that may be incorrectly coded, thus providing a measure of data quality. There are 31 obstetric indicators available for the ICD-10-AM Fourth Edition. Twenty of these 31 indicators were classified as Fatal, nine as Warning and two Relative. These indicators were used to examine coding quality of obstetric records in the 2004-2005 financial year Australian national hospital morbidity dataset. Records with obstetric disease or procedure codes listed anywhere in the code string were extracted and exported from the SPSS source file. Data were then imported into a Microsoft Access database table as per PICQ instructions, and run against all Fatal and Warning and Relative (N=31) obstetric PICQ 2006 Fourth Edition Indicators v.5 for the ICD-10- AM Fourth Edition. There were 689,905 gynaecological and obstetric records in the 2004-2005 financial year, of which 1.14% were found to have triggered Fatal degree errors, 3.78% Warning degree errors and 8.35% Relative degree errors. The types of errors include completeness, redundancy, specificity and sequencing problems. It was found that PICQ is a useful initial screening tool for the assessment of ICD-10-AM/ACHI coding quality. The overall quality of codes assigned to obstetric records in the 2004- 2005 Australian national morbidity dataset is of fair quality.

  16. Objective assessment of operator performance during ultrasound-guided procedures.

    PubMed

    Tabriz, David M; Street, Mandie; Pilgram, Thomas K; Duncan, James R

    2011-09-01

    Simulation permits objective assessment of operator performance in a controlled and safe environment. Image-guided procedures often require accurate needle placement, and we designed a system to monitor how ultrasound guidance is used to monitor needle advancement toward a target. The results were correlated with other estimates of operator skill. The simulator consisted of a tissue phantom, ultrasound unit, and electromagnetic tracking system. Operators were asked to guide a needle toward a visible point target. Performance was video-recorded and synchronized with the electromagnetic tracking data. A series of algorithms based on motor control theory and human information processing were used to convert raw tracking data into different performance indices. Scoring algorithms converted the tracking data into efficiency, quality, task difficulty, and targeting scores that were aggregated to create performance indices. After initial feasibility testing, a standardized assessment was developed. Operators (N = 12) with a broad spectrum of skill and experience were enrolled and tested. Overall scores were based on performance during ten simulated procedures. Prior clinical experience was used to independently estimate operator skill. When summed, the performance indices correlated well with estimated skill. Operators with minimal or no prior experience scored markedly lower than experienced operators. The overall score tended to increase according to operator's clinical experience. Operator experience was linked to decreased variation in multiple aspects of performance. The aggregated results of multiple trials provided the best correlation between estimated skill and performance. A metric for the operator's ability to maintain the needle aimed at the target discriminated between operators with different levels of experience. This study used a highly focused task model, standardized assessment, and objective data analysis to assess performance during simulated

  17. Applicability of ambient toxicity testing to national or regional water-quality assessment

    USGS Publications Warehouse

    Elder, J.F.

    1989-01-01

    Comprehensive assessment of the quality of natural waters requires a multifaceted approach. Based on experimentation designed to monitor responses of organisms to environmental stresses, toxicity testing may have diverse purposes in water quality assessments. These purposes may include identification that warrant further study because of poor water quality or unusual ecological features, verification of other types of monitoring, or assessment of contaminant effects on aquatic communities. A wide variety of toxicity test methods have been developed to fulfill the needs of diverse applications. The methods differ primarily in the full selections made relative to four characteristics: (1) test species, (2) endpoints (acute or chronic), (3) test enclosure type, and (4) test substance (toxicant) that functions as the environmental stress. Toxicity test approachs vary in their capacity to meet the needs of large-scale assessments of existing water quality. Ambient testing is more likely to meet these needs than are the procedures that call for exposure of the test organisms to known concentrations of a single toxicant. However, meaningful interpretation of ambient test results depend on the existence of accompanying chemical analysis of the ambient media. The ambient test substance may be water or sediments. Sediment tests have had limited application, but they are useful because of the fact that most toxicants tend to accumulate in sediments, and many test species either inhabit the sediments or are in frequent contact with them. Biochemical testing methods, which have been developing rapidly in recent years, are likely to be among the most useful procedures for large-scale water quality assessments. They are relatively rapid and simple, and more importantly, they focus on biochemical changes that are the initial responses of virtually all organisms to environmental stimuli. Most species are sensitive to relatively few toxicants and their sensitivities vary as

  18. [Procedure of seed quality testing and seed grading standard of Prunus humilis].

    PubMed

    Wen, Hao; Ren, Guang-Xi; Gao, Ya; Luo, Jun; Liu, Chun-Sheng; Li, Wei-Dong

    2014-11-01

    So far there exists no corresponding quality test procedures and grading standards for the seed of Prunus humilis, which is one of the important source of base of semen pruni. Therefor we set up test procedures that are adapt to characteristics of the P. humilis seed through the study of the test of sampling, seed purity, thousand-grain weight, seed moisture, seed viability and germination percentage. 50 cases of seed specimens of P. humilis tested. The related data were analyzed by cluster analysis. Through this research, the seed quality test procedure was developed, and the seed quality grading standard was formulated. The seed quality of each grade should meet the following requirements: for first grade seeds, germination percentage ≥ 68%, thousand-grain weight 383 g, purity ≥ 93%, seed moisture ≤ 5%; for second grade seeds, germination percentage ≥ 26%, thousand-grain weight ≥ 266 g, purity ≥ 73%, seed moisture ≤9%; for third grade seeds, germination percentage ≥ 10%, purity ≥ 50%, thousand-grain weight ≥ 08 g, seed moisture ≤ 13%.

  19. A quality assessment tool for markup-based clinical guidelines.

    PubMed

    Shalom, Erez; Shahar, Yuval; Taieb-Maimon, Meirav; Lunenfeld, Eitan

    2008-11-06

    We introduce a tool for quality assessment of procedural and declarative knowledge. We developed this tool for evaluating the specification of mark-up-based clinical GLs. Using this graphical tool, the expert physician and knowledge engineer collaborate to perform scoring, using pre-defined scoring scale, each of the knowledge roles of the mark-ups, comparing it to a gold standard. The tool enables scoring the mark-ups simultaneously at different sites by different users at different locations.

  20. (High temperature flaw assessment procedure)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruggles, M.B.

    1990-06-01

    The Electric Power Research Institute (EPRI), the Japanese Central Research Institute of Electric Power Industry (CRIEPI), and the British Nuclear Electric (NE) are conducting joint studies in the field of liquid metal reactor development. The traveler is currently responsible for the EPRI/CRIEPI/NE High-Temperature Flaw Assessment Procedure activities at the Oak Ridge National Laboratory (ORNL). The traveler participated, on behalf of EPRI, in the EPRI/CRIEPI/NE specialist working session, the purpose of which was to produce the interim High-Temperature Flaw Assessment guide. The traveler also led discussions on the High-Temperature Flaw Assessment Procedure Phase 2 program plan, and on the plan formore » a new joint EPRI/CRIEPI/NE study in Inelastic Behavior and Failure Criteria for Modified 9Cr--1Mo Steel. The traveler visited Profs. K. Ikegami, Y. Asada, N. Ohno, T. Inoue, and K. Kaneko at the Tokyo Institute of Technology, the University of Tokyo, Nagoya University, Kyoto University, and Science University of Tokyo, respectively to hold discussions on research advances in the areas of high-temperature fracture mechanics, inelastic material behavior, and constitutive modeling. In addition, the traveler visited Kajima Corp. and Ohbayashi Corp. Technical Research Institute to collect information on research in the area of fiber reinforced concrete.« less

  1. Assessment of sperm DNA in patients submitted the assisted reproduction technology procedures.

    PubMed

    Tsuribe, Patrícia Miyuki; Lima Neto, João Ferreira; Golim, Marjorie de Assis; Dell'Aqua, Camila de Paula Freitas; Issa, João Paulo; Gobbo, Carlos Alberto Monte

    2016-03-01

    This study aimed to produce data on sperm quality while maintaining the integrity of sperm DNA samples taken from patients submitted to in vitro fertilization (IVF) procedures at our center, and determine whether increased levels of histones were associated with sperm DNA damage and decreased fertilization, cleavage, and pregnancy rates. Such findings might shed light on the physiology and outcomes of pregnancy. Semen samples from 27 patients divided into two groups were analyzed. The case group included individuals offered IVF; the control group had subjects with normal spermograms. Sperm DNA structure was assessed through phosphorylated histone H2AX analysis by flow cytometry. The patients with altered sperm parameters had more histones in sperm chromatin than the individuals with normal sperm parameters. Results indicated that increased levels of histone in sperm chromatin do not affect embryo production, but affect the cleavage rate, embryo quality, and might thus reduce pregnancy rates. The integrity of the paternal genome is of paramount importance in the initiation and maintenance of a viable pregnancy in patients treated with assisted reproduction technology procedures. Further studies on sperm diagnostic tests at a nuclear level might improve the treatment offered to infertile couples.

  2. Assessment in Counseling: A Guide to the Use of Psychological Assessment Procedures. Third Edition.

    ERIC Educational Resources Information Center

    Hood, Albert B.; Johnson, Richard W.

    This book presents information about various psychological assessment procedures that are specifically relevant for practicing counselors. It deals with the use of assessment procedures in the counseling process and emphasizes the selection, interpretation, and communication of psychological test results. The importance of integrating test results…

  3. Improving L2 Reading Comprehension through Emotionalized Dynamic Assessment Procedures.

    PubMed

    Abdolrezapour, Parisa

    2017-06-01

    The paper reports a study on an emotionally-loaded dynamic assessment procedure used with Iranian EFL learners. It focuses on the effect of using emotional intelligence characteristics (based on Goleman's framework) as a tool for motivating learners while performing reading tasks. The study with 50 intermediate learners aged 12-15 used three modalities: a control group, which was taught under institute's normal procedures; a comparison group, which received dynamic assessment (DA); and an experimental group, which received emotionalized dynamic assessment (EDA) procedures, in the form of an intervention focusing on characteristics of Goleman's emotional intelligence framework with the express purpose of inducing them to work with their emotions. Results showed that applying EDA procedures to reading assessment tasks made a difference in learners' level of performance in comparison to those who went through pure DA procedures who in turn performed significantly better than those who did not received DA in any form.

  4. Quality of Widely Available Video Instructional Materials for Point-of-Care Ultrasound-Guided Procedure Training in Internal Medicine.

    PubMed

    Khandelwal, Aditi; Devine, Luke A; Otremba, Mirek

    2017-07-01

    Many instructional materials for point-of-care ultrasound (US)-guided procedures exist; however, their quality is unknown. This study assessed widely available educational videos for point-of-care US-guided procedures relevant to internal medicine: central venous catheterization, thoracentesis, and paracentesis. We searched Ovid MEDLINE, YouTube, and Google to identify videos for point-of-care US-guided paracentesis, thoracentesis, and central venous catheterization. Videos were evaluated with a 5-point scale assessing the global educational value and a checklist based on consensus guidelines for competencies in point-of-care US-guided procedures. For point-of-care US-guided central venous catheterization, 12 videos were found, with an average global educational value score ± SD of 4.5 ± 0.7. Indications to abort the procedure were discussed in only 3 videos. Five videos described the indications and contraindications for performing central venous catheterization. For point-of-care US-guided thoracentesis, 8 videos were identified, with an average global educational value score of 4.0 ± 0.9. Only one video discussed indications to abort the procedure, and 3 videos discussed sterile technique. For point-of-care US-guided paracentesis, 7 videos were included, with an average global educational value score of 4.1 ± 0.9. Only 1 video discussed indications to abort the procedure, and 2 described the location of the inferior epigastric artery. The 27 videos reviewed contained good-quality general instruction. However, we noted a lack of safety-related information in most of the available videos. Further development of resources is required to teach internal medicine trainees skills that focus on the safety of point-of-care US guidance. © 2017 by the American Institute of Ultrasound in Medicine.

  5. Integrating Multiple Criteria in Selection Procedures for Improving Student Quality and Reducing Cost Per Graduate. AIR Forum 1979 Paper.

    ERIC Educational Resources Information Center

    Jones, Gerald L.; Westen, Risdon J.

    The multivariate approach of canonical correlation was used to assess selection procedures of the Air Force Academy. It was felt that improved student selection methods might reduce the number of dropouts while maintaining or improving the quality of graduates. The method of canonical correlation was designed to maximize prediction of academic…

  6. 77 FR 23208 - Assessment of Mediation and Arbitration Procedures

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-18

    ... No. EP 699] Assessment of Mediation and Arbitration Procedures AGENCY: Surface Transportation Board... Mediation and Arbitration Procedures, EP 699 (STB served Mar. 28, 2012),\\1\\ the Surface Transportation Board... favors the resolution of disputes through the use of mediation and arbitration procedures, in lieu of...

  7. Quality-of-Life Assessment of Fibroid Treatment Options and Outcomes

    PubMed Central

    Kong, Chung Yin; Tempany, Clare M.; Swan, J. Shannon

    2011-01-01

    Purpose: To obtain utilities (a unit of measure of a person’s relative preferences for different health states compared with death or worst possible outcome) for uterine fibroids before and after treatment and to measure short-term utilities for the following uterine fibroid treatments: abdominal hysterectomy, magnetic resonance (MR) imaging–guided focused ultrasound surgery, and uterine artery embolization (UAE). Materials and Methods: This retrospective study was approved by the institutional review board and was HIPAA compliant. The waiting trade-off (WTO) method, a variation on the time trade-off (TTO) method, is used to obtain utilities for diagnostic procedures on the basis of the fact that people wait longer to avoid noxious tests and/or procedures. The WTO method provides short-term quality of life tolls in terms of quality-adjusted life-weeks by scaling wait times with pre- and posttreatment utilities. Utilities for uterine fibroids before and after treatment were obtained with the TTO method and a visual analog scale (VAS) by using a questionnaire administered by means of a phone interview. WTO wait times were adjusted for quality of life with VAS and TTO utilities and a transformation of VAS. Wait times were compared by using nonparametric tests. The study participants included 62 patients who had undergone abdominal hysterectomy, 74 who had undergone UAE, and 61 who had undergone MR imaging–guided focused ultrasound surgery. Results: Quality of life increased with all treatments. The median WTO wait time was higher for hysterectomy (21.6 weeks) than for UAE or MR imaging–guided focused ultrasound surgery (14.1 weeks for both) (P < .05). Quality-adjusted life-week tolls were smaller when scaled according to TTO than when scaled according to VAS or transformation of VAS. Conclusion: Quality of life increased after all fibroid treatments. WTO is feasible for assessing the quality-adjusted morbidity of treatment procedures. © RSNA, 2011

  8. European Standards for Quality Assurance and Institutional Practices of Student Assessment in the UK, the Netherlands and the Czech Republic

    ERIC Educational Resources Information Center

    Kohoutek, Jan

    2014-01-01

    This article analyses the student assessment procedures of 12 universities in the UK, the Netherlands and the Czech Republic with respect to their alignment with the European standards and guidelines on the quality of assessing higher education students (European Standards and Guidelines for Quality Assurance [ESG] 1.3). Based on qualitative…

  9. Development of ecotoxicology procedures for use in assessing health of coral reefs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davies, P.S.; Marubini, F.

    1995-12-31

    There is widespread concern over the apparent worldwide decline in the health of coral reefs. However, assessment methods, other than long-term monitoring, have not yet been attempted. To remedy this the authors are developing ecotoxicology procedures to assess the effects of water quality factors on the corals themselves. Because of the problems of working with large, attached organisms, the authors have concentrated on developing small clonal preparations from corals with both a branching and a massive growth-form. For branching corals, tips (`nubbins`) are removed, and the cut surface ground smooth before cementing to 30mm x 30mm acrylic squares. Cores, ormore » `explants`, 25mm in diameter are removed from massive corals and cemented into injection-moulded plastic cups, to protect the cut surfaces of the skeleton. Trays of up to 18 nubbins and explants may then be transferred to the reef, where they are affixed to previously installed concrete breeze blocks. They may then be retrieved as required to assess the effects of water quality upon them. For laboratory ecotoxicology experiments, the authors have devised a system of artificial lighting, using halide lamps, to grow coral nubbins and explants under controlled conditions. To test the effects of pollutants, the authors use measurements of respiration, photosynthesis and skeletal growth rate. Growth is measured by a very simple buoyant weighing procedure, which requires only an analytical laboratory balance, and an easily-constructed plastic box-shaped chamber. The method is sufficiently sensitive to measure growth over a 24 hour period in some fast-growing corals. The authors will describe the results of initial experiments, carried out at the Bellairs Research Institute, Barbados, on the effects of different levels of phosphate and nitrate in the seawater. For the first time, they are able to demonstrate the concentration-related decrease in growth rate associated with nitrate eutrophication.« less

  10. Development of the Quality Assurance/Quality Control Procedures for a Neutron Interrogation System

    NASA Astrophysics Data System (ADS)

    Obhođaš, Jasmina; Sudac, Davorin; Valković, Vladivoj

    2016-06-01

    In order to perform Quality Assurance/Quality Control (QA/QC) procedures for a system dedicated to the neutron interrogation of objects for the presence of threat materials one needs to perform measurements of reference materials (RM) i.e. simulants having the same (or similar) atomic ratios as real materials. It is well known that explosives, drugs, and various other benign materials, contain chemical elements such as hydrogen, oxygen, carbon and nitrogen in distinctly different quantities. For example, a high carbon-to-oxygen ratio (C/O) is characteristic of drugs. Explosives can be differentiated by measurement of both (C/O) and nitrogen-to-oxygen (N/O) ratios. The C/N ratio of the chemical warfare agents, coupled with the measurement of elements such as fluorine and phosphorus, clearly differentiate them from the conventional explosives. Here we present the RM preparation, calibration procedure and correlations attained between theoretical values and experimentally obtained results in laboratory conditions for C/O and N/C ratios of prepared hexogen (RDX), TNT, DLM2, TATP, cocaine, heroin, yperite, tetranitromethane, peroxide methylethylketone, nitromethane and ethyleneglycol dinitrate simulants. We have shown that analyses of the gamma ray spectra by using simple unfolding model developed for this purpose gave a nice agreement with the chemical formula of created simulants, thus the calibration quality was successfully tested.

  11. The Northeast Stream Quality Assessment

    USGS Publications Warehouse

    Van Metre, Peter C.; Riva-Murray, Karen; Coles, James F.

    2016-04-22

    In 2016, the U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) is assessing stream quality in the northeastern United States. The goal of the Northeast Stream Quality Assessment (NESQA) is to assess the quality of streams in the region by characterizing multiple water-quality factors that are stressors to aquatic life and evaluating the relation between these stressors and biological communities. The focus of NESQA in 2016 will be on the effects of urbanization and agriculture on stream quality in all or parts of eight states: Connecticut, Massachusetts, New Hampshire, New Jersey, New York, Pennsylvania, Rhode Island, and Vermont.Findings will provide the public and policymakers with information about the most critical factors affecting stream quality, thus providing insights about possible approaches to protect the health of streams in the region. The NESQA study will be the fourth regional study conducted as part of NAWQA and will be of similar design and scope to the first three, in the Midwest in 2013, the Southeast in 2014, and the Pacific Northwest in 2015 (http://txpub.usgs.gov/RSQA/).

  12. Quality assessment of urban environment

    NASA Astrophysics Data System (ADS)

    Ovsiannikova, T. Y.; Nikolaenko, M. N.

    2015-01-01

    This paper is dedicated to the research applicability of quality management problems of construction products. It is offered to expand quality management borders in construction, transferring its principles to urban systems as economic systems of higher level, which qualitative characteristics are substantially defined by quality of construction product. Buildings and structures form spatial-material basis of cities and the most important component of life sphere - urban environment. Authors justify the need for the assessment of urban environment quality as an important factor of social welfare and life quality in urban areas. The authors suggest definition of a term "urban environment". The methodology of quality assessment of urban environment is based on integrated approach which includes the system analysis of all factors and application of both quantitative methods of assessment (calculation of particular and integrated indicators) and qualitative methods (expert estimates and surveys). The authors propose the system of indicators, characterizing quality of the urban environment. This indicators fall into four classes. The authors show the methodology of their definition. The paper presents results of quality assessment of urban environment for several Siberian regions and comparative analysis of these results.

  13. Methodologic issues in assessing the quality of life of cancer patients.

    PubMed

    Aaronson, N K

    1991-02-01

    Although quality of life assessments have been employed successfully in descriptive and evaluative studies in oncology, their use in cancer clinical trials has, to date, been limited. A range of issues have impeded the conduct of clinical trial-based quality of life investigations. These include: the absence of theoretical models to guide the development of quality of life measures; over-reliance on ad hoc approaches to quality of life assessment; and insufficient attention to the practical constraints operating in clinical research settings. Of primary importance is the need to develop multidimensional quality of life instruments that are brief and psychometrically robust. It is suggested that future work on instrument development focus on refining currently available generic or cancer-specific measures, and on developing new diagnostic-specific questionnaire modules. This psychometric work should be guided by appropriate theoretical models of the relationship among health-related quality of life domains. Although it is widely accepted that the patient represents the most appropriate source of quality of life data, it is suggested that efforts also be directed toward improving the validity and reliability of physician-generated assessments of patients' performance status and of treatment toxicities, and toward determining the feasibility of employing family members as proxy raters of the psychologic and social health status of patients who are unwilling or unable to provide such information. Additional attention should be paid to the many logistical problems that arise in clinical trial-based quality of life investigations. In particular, research designs and data collection procedures should be selected that minimize patient, medical staff, and institutional burden.

  14. Concepts of Quality in Student Assessment.

    ERIC Educational Resources Information Center

    Harlen, Wynne

    This paper gives an overview of the methods of moderation, or quality assurance and quality control, as they may be more widely known, that are used to enhance the quality of student assessment. The discussion is based on the educational systems of the United Kingdom but is applicable to assessment in other countries. Quality in assessment is seen…

  15. The Measurement of Values: Effects of Different Assessment Procedures

    ERIC Educational Resources Information Center

    Feather, N. T.

    1973-01-01

    Rating and pair-comparison procedures for assessing the importance of terminal and instrumental values were compared with the standard ranking procedure developed by Rokeach. Effects of order of presentation of of the value sets were also investigated. Neither procedure nor order had replicable effect though some sex differences were apparent. (TO)

  16. French consensus procedure for assessing cognitive function in Parkinson's disease.

    PubMed

    Dujardin, K; Auzou, N; Lhommée, E; Czernecki, V; Dubois, B; Fradet, A; Maltete, D; Meyer, M; Pineau, F; Schmitt, E; Sellal, F; Tison, F; Vidal, T; Azulay, J-P; Welter, M-L; Corvol, J-C; Durif, F; Rascol, O

    2016-11-01

    One of the objectives of the French expert centers for Parkinson's disease (NS-Park) network was to determine a consensus procedure for assessing cognitive function in patients with Parkinson's. This article presents this procedure and briefly describes the selected tests. A group of 13 experts used the Delphi method for consensus building to define the overall structure and components of the assessment procedure. For inclusion in the battery, tests had to be validated in the French language, require little motor participation, have normative data and be recognized by the international community. Experimental tasks and tests requiring specific devices were excluded. Two possibilities were identified, depending on whether an abbreviated or comprehensive assessment of cognitive function was necessary. For an abbreviated assessment, the experts recommended the Montreal Cognitive Assessment (MoCA) as a screening test for cognitive impairment or dementia. For a comprehensive neuropsychological assessment, the experts recommended assessing global efficiency plus the five main cognitive domains (attention and working memory, executive function, episodic memory, visuospatial function and language) that may be impaired in Parkinson's disease, using two tests for each domain. A common procedure for assessing cognitive function is now available across the French network dedicated to Parkinson's disease, and is recommended for both research and clinical practice. It will also help to promote standardization of the neuropsychological assessment of Parkinson's disease. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  17. Soil bioassays as tools for sludge compost quality assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Domene, Xavier, E-mail: x.domene@creaf.uab.es; Sola, Laura; Ramirez, Wilson

    2011-03-15

    Composting is a waste management technology that is becoming more widespread as a response to the increasing production of sewage sludge and the pressure for its reuse in soil. In this study, different bioassays (plant germination, earthworm survival, biomass and reproduction, and collembolan survival and reproduction) were assessed for their usefulness in the compost quality assessment. Compost samples, from two different composting plants, were taken along the composting process, which were characterized and submitted to bioassays (plant germination and collembolan and earthworm performance). Results from our study indicate that the noxious effects of some of the compost samples observed inmore » bioassays are related to the low organic matter stability of composts and the enhanced release of decomposition endproducts, with the exception of earthworms, which are favored. Plant germination and collembolan reproduction inhibition was generally associated with uncomposted sludge, while earthworm total biomass and reproduction were enhanced by these materials. On the other hand, earthworm and collembolan survival were unaffected by the degree of composting of the wastes. However, this pattern was clear in one of the composting procedures assessed, but less in the other, where the release of decomposition endproducts was lower due to its higher stability, indicating the sensitivity and usefulness of bioassays for the quality assessment of composts.« less

  18. Statistical approaches used to assess and redesign surface water-quality-monitoring networks.

    PubMed

    Khalil, B; Ouarda, T B M J

    2009-11-01

    An up-to-date review of the statistical approaches utilized for the assessment and redesign of surface water quality monitoring (WQM) networks is presented. The main technical aspects of network design are covered in four sections, addressing monitoring objectives, water quality variables, sampling frequency and spatial distribution of sampling locations. This paper discusses various monitoring objectives and related procedures used for the assessment and redesign of long-term surface WQM networks. The appropriateness of each approach for the design, contraction or expansion of monitoring networks is also discussed. For each statistical approach, its advantages and disadvantages are examined from a network design perspective. Possible methods to overcome disadvantages and deficiencies in the statistical approaches that are currently in use are recommended.

  19. The creation, management, and use of data quality information for life cycle assessment.

    PubMed

    Edelen, Ashley; Ingwersen, Wesley W

    2018-04-01

    Despite growing access to data, questions of "best fit" data and the appropriate use of results in supporting decision making still plague the life cycle assessment (LCA) community. This discussion paper addresses revisions to assessing data quality captured in a new US Environmental Protection Agency guidance document as well as additional recommendations on data quality creation, management, and use in LCA databases and studies. Existing data quality systems and approaches in LCA were reviewed and tested. The evaluations resulted in a revision to a commonly used pedigree matrix, for which flow and process level data quality indicators are described, more clarity for scoring criteria, and further guidance on interpretation are given. Increased training for practitioners on data quality application and its limits are recommended. A multi-faceted approach to data quality assessment utilizing the pedigree method alongside uncertainty analysis in result interpretation is recommended. A method of data quality score aggregation is proposed and recommendations for usage of data quality scores in existing data are made to enable improved use of data quality scores in LCA results interpretation. Roles for data generators, data repositories, and data users are described in LCA data quality management. Guidance is provided on using data with data quality scores from other systems alongside data with scores from the new system. The new pedigree matrix and recommended data quality aggregation procedure can now be implemented in openLCA software. Additional ways in which data quality assessment might be improved and expanded are described. Interoperability efforts in LCA data should focus on descriptors to enable user scoring of data quality rather than translation of existing scores. Developing and using data quality indicators for additional dimensions of LCA data, and automation of data quality scoring through metadata extraction and comparison to goal and scope are needed.

  20. The California stream quality assessment

    USGS Publications Warehouse

    Van Metre, Peter C.; Egler, Amanda L.; May, Jason T.

    2017-03-06

    In 2017, the U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) project is assessing stream quality in coastal California, United States. The USGS California Stream Quality Assessment (CSQA) will sample streams over most of the Central California Foothills and Coastal Mountains ecoregion (modified from Griffith and others, 2016), where rapid urban growth and intensive agriculture in the larger river valleys are raising concerns that stream health is being degraded. Findings will provide the public and policy-makers with information regarding which human and natural factors are the most critical in affecting stream quality and, thus, provide insights about possible approaches to protect the health of streams in the region.

  1. Validity, reliability and support for implementation of independence-scaled procedural assessment in laparoscopic surgery.

    PubMed

    Kramp, Kelvin H; van Det, Marc J; Veeger, Nic J G M; Pierie, Jean-Pierre E N

    2016-06-01

    There is no widely used method to evaluate procedure-specific laparoscopic skills. The first aim of this study was to develop a procedure-based assessment method. The second aim was to compare its validity, reliability and feasibility with currently available global rating scales (GRSs). An independence-scaled procedural assessment was created by linking the procedural key steps of the laparoscopic cholecystectomy to an independence scale. Subtitled and blinded videos of a novice, an intermediate and an almost competent trainee, were evaluated with GRSs (OSATS and GOALS) and the independence-scaled procedural assessment by seven surgeons, three senior trainees and six scrub nurses. Participants received a short introduction to the GRSs and independence-scaled procedural assessment before assessment. The validity was estimated with the Friedman and Wilcoxon test and the reliability with the intra-class correlation coefficient (ICC). A questionnaire was used to evaluate user opinion. Independence-scaled procedural assessment and GRS scores improved significantly with surgical experience (OSATS p = 0.001, GOALS p < 0.001, independence-scaled procedural assessment p < 0.001). The ICCs of the OSATS, GOALS and independence-scaled procedural assessment were 0.78, 0.74 and 0.84, respectively, among surgeons. The ICCs increased when the ratings of scrub nurses were added to those of the surgeons. The independence-scaled procedural assessment was not considered more of an administrative burden than the GRSs (p = 0.692). A procedural assessment created by combining procedural key steps to an independence scale is a valid, reliable and acceptable assessment instrument in surgery. In contrast to the GRSs, the reliability of the independence-scaled procedural assessment exceeded the threshold of 0.8, indicating that it can also be used for summative assessment. It furthermore seems that scrub nurses can assess the operative competence of surgical trainees.

  2. Near patient testing in general practice: attitudes of general practitioners and practice nurses, and quality assurance procedures carried out.

    PubMed Central

    Hilton, S; Rink, E; Fletcher, J; Sibbald, B; Freeling, P; Szczepura, A; Davies, C; Stilwell, J

    1994-01-01

    BACKGROUND. The evaluation of near patient testing in British general practice has largely been confined to studies examining individual tests or comparing equipment. AIM. This study set out to determine the attitudes of practice staff to near patient testing, and the extent to which staff undertook quality assessment. METHOD. Four types of near patient testing machines were introduced into 12 general practices in two regions of England, south west Thames and west Midlands. General practitioner and practice nurse attitudes to near patient testing were assessed by semi-structured interview before and six months after the introduction of the machines. The extent to which routine quality assurance procedures were carried out within the surgery and as part of local and national schemes was examined. RESULTS. Although 80% of general practitioners anticipated changing patient management with near patient testing, only two fifths reported having done so after six months. Nurses generally were enthusiastic at the outset, although one third were unhappy about incorporating near patient testing into their work schedules. Time pressure was the most important factor restricting uptake of near patient testing. Nurses performed quality control regularly but complete local external quality assurance procedures were established in only half the practices. All the practices participated in a national scheme for cholesterol assays. CONCLUSION. General practitioners in this study did not find near patient testing a very useful addition to their resources. Pressure on nurses' time was the most frequently reported limitation. PMID:7748669

  3. Stability assessment of QKD procedures in commercial quantum cryptography systems versus quality of dark channel

    NASA Astrophysics Data System (ADS)

    Jacak, Monika; Melniczuk, Damian; Jacak, Janusz; Jóźwiak, Ireneusz; Gruber, Jacek; Jóźwiak, Piotr

    2015-02-01

    In order to assess the susceptibility of the quantum key distribution (QKD) systems to the hacking attack including simultaneous and frequent system self-decalibrations, we analyze the stability of the QKD transmission organized in two commercially available systems. The first one employs non-entangled photons as flying qubits in the dark quantum channel for communication whereas the second one utilizes the entangled photon pairs to secretly share the cryptographic key. Applying standard methods of the statistical data analysis to the characteristic indicators of the quality of the QKD communication (the raw key exchange rate [RKER] and the quantum bit error rate [QBER]), we have estimated the pace of the self-decalibration of both systems and the repeatability rate in the case of controlled worsening of the dark channel quality.

  4. Crowd-sourced assessment of surgical skills in cricothyrotomy procedure.

    PubMed

    Aghdasi, Nava; Bly, Randall; White, Lee W; Hannaford, Blake; Moe, Kris; Lendvay, Thomas S

    2015-06-15

    Objective assessment of surgical skills is resource intensive and requires valuable time of expert surgeons. The goal of this study was to assess the ability of a large group of laypersons using a crowd-sourcing tool to grade a surgical procedure (cricothyrotomy) performed on a simulator. The grading included an assessment of the entire procedure by completing an objective assessment of technical skills survey. Two groups of graders were recruited as follows: (1) Amazon Mechanical Turk users and (2) three expert surgeons from University of Washington Department of Otolaryngology. Graders were presented with a video of participants performing the procedure on the simulator and were asked to grade the video using the objective assessment of technical skills questions. Mechanical Turk users were paid $0.50 for each completed survey. It took 10 h to obtain all responses from 30 Mechanical Turk users for 26 training participants (26 videos/tasks), whereas it took 60 d for three expert surgeons to complete the same 26 tasks. The assessment of surgical performance by a group (n = 30) of laypersons matched the assessment by a group (n = 3) of expert surgeons with a good level of agreement determined by Cronbach alpha coefficient = 0.83. We found crowd sourcing was an efficient, accurate, and inexpensive method for skills assessment with a good level of agreement to experts' grading. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. An innovative procedure to assess multi-scale temporal trends in groundwater quality: Example of the nitrate in the Seine-Normandy basin, France

    NASA Astrophysics Data System (ADS)

    Lopez, Benjamin; Baran, Nicole; Bourgine, Bernard

    2015-03-01

    The European Water Framework Directive (WFD) asks Member States to identify trends in contaminant concentrations in groundwater and to take measures to reach a good chemical status by 2015. In this study, carried out in a large hydrological basin (95,300 km2), an innovative procedure is described for the assessment of recent trends in groundwater nitrate concentrations both at sampling point and regional scales. Temporal variograms of piezometric and nitrate concentration time series are automatically calculated and fitted in order to classify groundwater according to their temporal pattern. These results are then coupled with aquifer lithology to map spatial units within which the modes of diffuse transport of contaminants towards groundwater are assumed to be the same at all points. These spatial units are suitable for evaluating regional trends. The stability over time of the time series is tested based on the cumulative sum principle, to determine the time period during which the trend should be sought. The Mann-Kendall and Regional-Kendall nonparametric tests for monotonic trends, coupled with the Sen-slope test, are applied to the periods following the point breaks thus determined at both the sampling point or regional scales. This novel procedure is robust and enables rapid processing of large databases of raw data. It would therefore be useful for managing groundwater quality in compliance with the aims of the WFD.

  6. Standard operating procedures for neurophysiologic assessment of male sexual dysfunction.

    PubMed

    Giuliano, Francois; Rowland, David L

    2013-05-01

    Can neurophysiological testing in male patients with sexual dysfunction benefit the decision-making process? The answer remains unclear. To provide standard operating procedures for the neurophysiologic assessment of male sexual dysfunction. Medical literature was reviewed and combined with expert opinion of the authors. Bulbocavernosus reflex latency time, pudendal somatosensory evoked potentials, and sympathetic skin responses have been considered as potential candidates for the diagnosis and assessment of erectile dysfunction (ED). Currently, there is no consensus on a standardized methodology for these neurophysiological investigations in the overall assessment of ED. These procedures are unable to assess the integrity of the efferent parasympathetic proerectile penile innervation; accordingly, none of these assessment procedures is recommended for ED patients. Corpus cavernosum electromyography (CC-EMG) can detect abnormalities in cavernous smooth muscle although these alterations can be attributed both to damage to autonomic penile innervation and to degenerative processes of the cavernous smooth muscle. CC-EMG is still considered experimental. Evidence does not support that men with premature ejaculation (PE) are consistently characterized by penile hypersensitivity; accordingly, penile threshold determination is not recommended to in the diagnosis of PE. Neurophysiological investigation of other components of the penile sensory pathways in PE patients has not provided any definitive contribution to the diagnosis. No neurophysiological assessment procedures yield additional information that consistently aids in the assessment of PE and ED. © 2013 International Society for Sexual Medicine.

  7. Primary calibrations of radionuclide solutions and sources for the EML quality assessment program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisenne, I.M.

    1993-12-31

    The quality assurance procedures established for the operation of the U.S. Department of Energy`s Environmental Measurements Laboratory (DOE-EML`s) Quality Assessment Program (QAP) are essentially the same as those that are in effect for any EML program involving radiometric measurements. All these programs have at their core the use of radionuclide standards for their instrument calibration. This paper focuses on EML`s approach to the acquisition, calibration and application of a wide range of radionuclide sources that are required to meet its programmatic needs.

  8. A design procedure and handling quality criteria for lateral directional flight control systems

    NASA Technical Reports Server (NTRS)

    Stein, G.; Henke, A. H.

    1972-01-01

    A practical design procedure for aircraft augmentation systems is described based on quadratic optimal control technology and handling-quality-oriented cost functionals. The procedure is applied to the design of a lateral-directional control system for the F4C aircraft. The design criteria, design procedure, and final control system are validated with a program of formal pilot evaluation experiments.

  9. Assessment of emergency general surgery care based on formally developed quality indicators.

    PubMed

    Ingraham, Angela; Nathens, Avery; Peitzman, Andrew; Bode, Allison; Dorlac, Gina; Dorlac, Warren; Miller, Preston; Sadeghi, Mahsa; Wasserman, Deena D; Bilimoria, Karl

    2017-08-01

    Emergency general surgery outcomes vary widely across the United States. The utilization of quality indicators can reduce variation and assist providers in administering care aligned with established recommendations. Previous quality indicators have not focused on emergency general surgery patients. We identified indicators of high-quality emergency general surgery care and assessed patient- and hospital-level compliance with these indicators. We utilized a modified Delphi technique (RAND Appropriateness Methodology) to develop quality indicators. Through 2 rankings, an expert panel ranked potential quality indicators for validity. We then examined historic compliance with select quality indicators after 4 nonelective procedures (cholecystectomy, appendectomy, colectomy, small bowel resection) at 4 academic centers. Of 25 indicators rated as valid, 13 addressed patient-level quality and 12 addressed hospital-level quality. Adherence with 18 indicators was assessed. Compliance with performing a cholecystectomy for acute cholecystitis within 72 hours of symptom onset ranged from 45% to 76%. Compliance with surgery start times within 3 hours from the decision to operate for uncontained perforated viscus ranged from 20% to 100%. Compliance with exploration of patients with small bowel obstructions with ischemia/impending perforation within 3 hours of the decision to operate was 0% to 88%. For 3 quality indicators (auditing 30-day unplanned readmissions/operations for patients previously managed nonoperatively, monitoring time to source control for intra-abdominal infections, and having protocols for bypass/transfer), none of the hospitals were compliant. Developing indicators for providers to assess their performance provides a foundation for specific initiatives. Adherence to quality indicators may improve the quality of emergency general surgery care provided for which current outcomes are potentially modifiable. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Quality indicators for the assessment and management of pain in the emergency department: a systematic review.

    PubMed

    Stang, Antonia Schirmer; Hartling, Lisa; Fera, Cassandra; Johnson, David; Ali, Samina

    2014-01-01

    Evidence indicates that pain is undertreated in the emergency department (ED). The first step in improving the pain experience for ED patients is to accurately and systematically assess the actual care being provided. Identifying gaps in the assessment and treatment of pain and improving patient outcomes requires relevant, evidence-based performance measures. To systematically review the literature and identify quality indicators specific to the assessment and management of pain in the ED. Four major bibliographical databases were searched from January 1980 to December 2010, and relevant journals and conference proceedings were manually searched. Original research that described the development or collection of data on one or more quality indicators relevant to the assessment or management of pain in the ED was included. The search identified 18,078 citations. Twenty-three articles were included: 15 observational (cohort) studies; three before-after studies; three audits; one quality indicator development study; and one survey. Methodological quality was moderate, with weaknesses in the reporting of study design and methodology. Twenty unique indicators were identified, with the majority (16 of 20) measuring care processes. Overall, 91% (21 of 23) of the studies reported indicators for the assessment or management of presenting pain, as opposed to procedural pain. Three of the studies included children; however, none of the indicators were developed specifically for a pediatric population. Gaps in the existing literature include a lack of measures reflecting procedural pain, patient outcomes and the pediatric population. Future efforts should focus on developing indicators specific to these key areas.

  11. IERL-RTP PROCEDURES MANUAL: LEVEL 1 ENVIRONMENTAL ASSESSMENT BIOLOGICAL TESTS

    EPA Science Inventory

    The manual gives revised procedures for Level 1 environmental assessment biological tests, and supersedes the first edition, EPA-600/7-77-043 (NTIS No. PB 268484), published in April 1977. The revised biological procedures complement the Level 1 chemical and physical procedures p...

  12. Report from a quality assurance program on patients undergoing the MILD procedure.

    PubMed

    Durkin, Brian; Romeiser, Jamie; Shroyer, A Laurie W; Schiller, Robin; Bae, Jin; Davis, Raphael P; Peyster, Robert; Benveniste, Helene

    2013-05-01

    To characterize trends in pain and functional outcomes and identify risk factors in patients with lumbar spinal stenosis (LSS) and neurogenic claudication undergoing the "Minimally Invasive Lumbar Decompression" (MILD) procedure. Retrospective observational cohort study. Academic multidisciplinary pain center at Stony Brook Medicine. Patients undergoing the MILD procedure from October 2010 to November 2012. De-identified perioperative, pain and function related data for 50 patients undergoing MILD were extracted from the Center for Pain Management's quality assessment database. Data included numerical rating scale (NRS), symptom severity and physical function (Zurich Claudication Questionnaire), functional status (Oswestry Disability Index [ODI]), pain interference scores (National Institutes of Health Patient-Reported Outcomes Measurement Information System [PROMIS]), and patients' self-reported low back and lower extremity pain distribution. No MILD patient incurred procedure-related complications. Average NRS scores decreased postoperatively and 64.3% of patients reported less pain at 3 months. Clinically meaningful functional ODI improvements of at least 20% from baseline were present in 25% of the patients at 6 months. Preliminary analysis of changes in PROMIS scores at 3 months revealed that pre-MILD "severe" lumbar canal stenosis may be associated with high risk of "no improvement." No such impact was observed for NRS or ODI outcomes. Overall, pain is reduced and functional status improved in LSS patients following the MILD procedure at 3 and 6 months. Given the small sample size, it is not yet possible to identify patient subgroups at risk for "no improvement." Continued follow-up of longer-term outcomes appears warranted to develop evidence-based patient selection criteria. Wiley Periodicals, Inc.

  13. Methodological issues in the quantitative assessment of quality of life.

    PubMed

    Panagiotakos, Demosthenes B; Yfantopoulos, John N

    2011-10-01

    The term quality of life can be identified in Aristotle's classical writings of 330 BC. In his Nichomachian ethics he recognises the multiple relationships between happiness, well-being, "eudemonia" and quality of life. Historically the concept of quality of life has undergone various interpretations. It involves personal experience, perceptions and beliefs, attitudes concerning philosophical, cultural, spiritual, psychological, political, and financial aspects of everyday living. Quality of life has been extensively used both as an outcome and an explanatory factor in relation to human health, in various clinical trials, epidemiologic studies and health interview surveys. Because of the variations in the definition of quality of life, both in theory and in practice, there are also a wide range of procedures that are used to assess quality of life. In this paper several methodological issues regarding the tools used to evaluate quality of life is discussed. In summary, the use of components consisted of large number of classes, as well as the use of specific weights for each scale component, and the low-to-moderate inter-correlation level between the components, is evident from simulated and empirical studies.

  14. Constructing Ecological Networks Based on Habitat Quality Assessment: A Case Study of Changzhou, China

    NASA Astrophysics Data System (ADS)

    Gao, Yu; Ma, Lei; Liu, Jiaxun; Zhuang, Zhuzhou; Huang, Qiuhao; Li, Manchun

    2017-04-01

    Fragmentation and reduced continuity of habitat patches threaten the environment and biodiversity. Recently, ecological networks are increasingly attracting the attention of researchers as they provide fundamental frameworks for environmental protection. This study suggests a set of procedures to construct an ecological network. First, we proposed a method to construct a landscape resistance surface based on the assessment of habitat quality. Second, to analyze the effect of the resistance surface on corridor simulations, we used three methods to construct resistance surfaces: (1) the method proposed in this paper, (2) the entropy coefficient method, and (3) the expert scoring method. Then, we integrated habitat patches and resistance surfaces to identify potential corridors using graph theory. These procedures were tested in Changzhou, China. Comparing the outputs of using different resistance surfaces demonstrated that: (1) different landscape resistance surfaces contribute to how corridors are identified, but only slightly affect the assessment of the importance of habitat patches and potential corridors; (2) the resistance surface, which is constructed based on habitat quality, is more applicable to corridor simulations; and (3) the assessment of the importance of habitat patches is fundamental for ecological network optimization in the conservation of critical habitat patches and corridors.

  15. EPA's Quality Policy and Procedure CIO Policy Transmittal 09-001

    EPA Pesticide Factsheets

    The purpose of this memo is to (1) issue the final versions of the Quality Policy and Procedure documents (with a Q&A document for your reference as well) and (2) call for members of a new advisory group to guide Policy implementation activities.

  16. Teaching and assessing procedural skills using simulation: metrics and methodology.

    PubMed

    Lammers, Richard L; Davenport, Moira; Korley, Frederick; Griswold-Theodorson, Sharon; Fitch, Michael T; Narang, Aneesh T; Evans, Leigh V; Gross, Amy; Rodriguez, Elliot; Dodge, Kelly L; Hamann, Cara J; Robey, Walter C

    2008-11-01

    Simulation allows educators to develop learner-focused training and outcomes-based assessments. However, the effectiveness and validity of simulation-based training in emergency medicine (EM) requires further investigation. Teaching and testing technical skills require methods and assessment instruments that are somewhat different than those used for cognitive or team skills. Drawing from work published by other medical disciplines as well as educational, behavioral, and human factors research, the authors developed six research themes: measurement of procedural skills; development of performance standards; assessment and validation of training methods, simulator models, and assessment tools; optimization of training methods; transfer of skills learned on simulator models to patients; and prevention of skill decay over time. The article reviews relevant and established educational research methodologies and identifies gaps in our knowledge of how physicians learn procedures. The authors present questions requiring further research that, once answered, will advance understanding of simulation-based procedural training and assessment in EM.

  17. Improving the safety and quality of nursing care through standardized operating procedures in Bosnia and Herzegovina.

    PubMed

    Ausserhofer, Dietmar; Rakic, Severin; Novo, Ahmed; Dropic, Emira; Fisekovic, Eldin; Sredic, Ana; Van Malderen, Greet

    2016-06-01

    We explored how selected 'positive deviant' healthcare facilities in Bosnia and Herzegovina approach the continuous development, adaptation, implementation, monitoring and evaluation of nursing-related standard operating procedures. Standardized nursing care is internationally recognized as a critical element of safe, high-quality health care; yet very little research has examined one of its key instruments: nursing-related standard operating procedures. Despite variability in Bosnia and Herzegovina's healthcare and nursing care quality, we assumed that some healthcare facilities would have developed effective strategies to elevate nursing quality and safety through the use of standard operating procedures. Guided by the 'positive deviance' approach, we used a multiple-case study design to examine a criterion sample of four facilities (two primary healthcare centres and two hospitals), collecting data via focus groups and individual interviews. In each studied facility, certification/accreditation processes were crucial to the initiation of continuous development, adaptation, implementation, monitoring and evaluation of nursing-related SOPs. In one hospital and one primary healthcare centre, nurses working in advanced roles (i.e. quality coordinators) were responsible for developing and implementing nursing-related standard operating procedures. Across the four studied institutions, we identified a consistent approach to standard operating procedures-related processes. The certification/accreditation process is enabling necessary changes in institutions' organizational cultures, empowering nurses to take on advanced roles in improving the safety and quality of nursing care. Standardizing nursing procedures is key to improve the safety and quality of nursing care. Nursing and Health Policy are needed in Bosnia and Herzegovina to establish a functioning institutional framework, including regulatory bodies, educational systems for developing nurses' capacities or the

  18. Higher Education Quality Assessment Model: Towards Achieving Educational Quality Standard

    ERIC Educational Resources Information Center

    Noaman, Amin Y.; Ragab, Abdul Hamid M.; Madbouly, Ayman I.; Khedra, Ahmed M.; Fayoumi, Ayman G.

    2017-01-01

    This paper presents a developed higher education quality assessment model (HEQAM) that can be applied for enhancement of university services. This is because there is no universal unified quality standard model that can be used to assess the quality criteria of higher education institutes. The analytical hierarchy process is used to identify the…

  19. 40 CFR Appendix C to Part 61 - Quality Assurance Procedures

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 9 2014-07-01 2014-07-01 false Quality Assurance Procedures C Appendix C to Part 61 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS Pt. 61, App. C Appendix C to Part 61...

  20. Spatial Data Quality Control Procedure applied to the Okavango Basin Information System

    NASA Astrophysics Data System (ADS)

    Butchart-Kuhlmann, Daniel

    2014-05-01

    Spatial data is a powerful form of information, capable of providing information of great interest and tremendous use to a variety of users. However, much like other data representing the 'real world', precision and accuracy must be high for the results of data analysis to be deemed reliable and thus applicable to real world projects and undertakings. The spatial data quality control (QC) procedure presented here was developed as the topic of a Master's thesis, in the sphere of and using data from the Okavango Basin Information System (OBIS), itself a part of The Future Okavango (TFO) project. The aim of the QC procedure was to form the basis of a method through which to determine the quality of spatial data relevant for application to hydrological, solute, and erosion transport modelling using the Jena Adaptable Modelling System (JAMS). As such, the quality of all data present in OBIS classified under the topics of elevation, geoscientific information, or inland waters, was evaluated. Since the initial data quality has been evaluated, efforts are underway to correct the errors found, thus improving the quality of the dataset.

  1. Formative Assessment of Procedural Skills: Students' Responses to the Objective Structured Clinical Examination and the Integrated Performance Procedural Instrument

    ERIC Educational Resources Information Center

    Nestel, Debra; Kneebone, Roger; Nolan, Carmel; Akhtar, Kash; Darzi, Ara

    2011-01-01

    Assessment of clinical skills is a critical element of undergraduate medical education. We compare a traditional approach to procedural skills assessment--the Objective Structured Clinical Examination (OSCE) with the Integrated Performance Procedural Instrument (IPPI). In both approaches, students work through "stations" or…

  2. Assessment in Counseling: Procedures and Practices, Sixth Edition

    ERIC Educational Resources Information Center

    Hays, Danica G.

    2017-01-01

    The latest edition of this perennial bestseller instructs and updates students and clinicians on the basic principles of psychological assessment and measurement, recent changes in assessment procedures, and the most widely used tests in counseling practice today. Dr. Danica Hays guides counselors in the appropriate selection, interpretation, and…

  3. Assessment of the MPACT Resonance Data Generation Procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Kang Seog; Williams, Mark L.

    Currently, heterogeneous models are being used to generate resonance self-shielded cross-section tables as a function of background cross sections for important nuclides such as 235U and 238U by performing the CENTRM (Continuous Energy Transport Model) slowing down calculation with the MOC (Method of Characteristics) spatial discretization and ESSM (Embedded Self-Shielding Method) calculations to obtain background cross sections. And then the resonance self-shielded cross section tables are converted into subgroup data which are to be used in estimating problem-dependent self-shielded cross sections in MPACT (Michigan Parallel Characteristics Transport Code). Although this procedure has been developed and thus resonance data have beenmore » generated and validated by benchmark calculations, assessment has never been performed to review if the resonance data are properly generated by the procedure and utilized in MPACT. This study focuses on assessing the procedure and a proper use in MPACT.« less

  4. 42 CFR 476.170 - General quality of care reconsideration procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Qio Review Functions § 476.170 General quality of care reconsideration procedures. (a) Right to... practitioner who is dissatisfied with a QIO's initial determination may request a reconsideration by the QIO... than 3 calendar days following receipt of the QIO's initial determination. If the QIO is unable to...

  5. 42 CFR 476.170 - General quality of care reconsideration procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... General quality of care reconsideration procedures. (a) Right to request a reconsideration. Beginning with reviews initiated after July 31, 2014, a provider or practitioner who is dissatisfied with a QIO's initial... QIO, in writing or by telephone, by no later than 3 calendar days following receipt of the QIO's...

  6. Standard procedures and quality-control practices for the U.S. Geological Survey National Field Quality Assurance Program from 1982 through 1993

    USGS Publications Warehouse

    Stanley, D.L.

    1995-01-01

    The U.S. Geological Survey operates the National Field Quality Assurance Program to provide quality- assurance reference samples to field personnel who make water-quality field measurements. The program monitors the accuracy and precision of pH, specific conductance, and alkalinity field measurements. This report documents the operational procedures and quality-control techniques used in operating the quality-assurance program.

  7. Using the Entrustable Professional Activities Framework in the Assessment of Procedural Skills.

    PubMed

    Pugh, Debra; Cavalcanti, Rodrigo B; Halman, Samantha; Ma, Irene W Y; Mylopoulos, Maria; Shanks, David; Stroud, Lynfa

    2017-04-01

    The entrustable professional activity (EPA) framework has been identified as a useful approach to assessment in competency-based education. To apply an EPA framework for assessment, essential skills necessary for entrustment to occur must first be identified. Using an EPA framework, our study sought to (1) define the essential skills required for entrustment for 7 bedside procedures expected of graduates of Canadian internal medicine (IM) residency programs, and (2) develop rubrics for the assessment of these procedural skills. An initial list of essential skills was defined for each procedural EPA by focus groups of experts at 4 academic centers using the nominal group technique. These lists were subsequently vetted by representatives from all Canadian IM training programs through a web-based survey. Consensus (more than 80% agreement) about inclusion of each item was sought using a modified Delphi exercise. Qualitative survey data were analyzed using a framework approach to inform final assessment rubrics for each procedure. Initial lists of essential skills for procedural EPAs ranged from 10 to 24 items. A total of 111 experts completed the national survey. After 2 iterations, consensus was reached on all items. Following qualitative analysis, final rubrics were created, which included 6 to 10 items per procedure. These EPA-based assessment rubrics represent a national consensus by Canadian IM clinician educators. They provide a practical guide for the assessment of procedural skills in a competency-based education model, and a robust foundation for future research on their implementation and evaluation.

  8. Quality Assessment of Family Planning Sterilization Services at Health Care Facilities: Case Record Audit.

    PubMed

    Mathur, Medha; Goyal, Ram Chandra; Mathur, Navgeet

    2017-05-01

    Quality of sterilization services is a matter of concern in India because population control is a necessity. Family Planning Sterilization (FPS) services provided at public health care facilities need to be as per Standard Operating Procedures. To assess the quality of FPS services by audit of case records at selected health care facilities. This cross-sectional study was conducted for two and a half year duration at selected public health care facilities of central India by simple random sampling where FPS services were provided. As per the standards of Government of India, case records were audited and compliance was calculated to assess the quality of services. Results of record audit were satisfactory but important criteria like previous contraceptive history and postoperative counselling were found to be deviated from standards. At Primary Health Centres (PHCs) only 89.5% and at Community Health Centres (CHCs) 58.7% of records were having details of previous contraceptive history. Other criteria like mental illness (only 70% at CHCs) assessment were also inadequate. Although informed consent was found to be having 100% compliance in all records. Quality of care in FPS services is the matter of concern in present scenario for better quality of services. This study may enlighten the policy makers regarding improvements needed for providing quality care.

  9. High quality data: An evaluation of AIM data quality and data quality procedures

    USDA-ARS?s Scientific Manuscript database

    The goal of every monitoring program is to collect high-quality data which can then be used to provide information to decision makers. The Bureau of Land Management (BLM) Assessment, Inventory, and Monitoring (AIM) program is one such data set which provides rangeland status, condition, and trend in...

  10. How to assess quality of life in child and adolescent psychiatry

    PubMed Central

    Ravens-Sieberer, Ulrike; Karow, Anne; Barthel, Dana; Klasen, Fionna

    2014-01-01

    This article provides an overview of the conceptual foundations of measuring health-related quality of life (HRQoL) in children and adolescents in child and adolescent psychiatry, and of the current state of research in this field. The available procedures for determining quality of life are presented according to their areas of use and their psychometric characteristics. The internationally available generic instruments for measuring HRQoL in children are identified and assessed in terms of their strengths and weaknesses with regard to selected criteria. As a result, seven generic HRQoL instruments and two utility procedures have been identified which satísfy the following criteria: (i) psychometric qualíty; (ii) age-appropriate measurement; (iii) versions for self-reporting and external rating; and (iv) cross-cultural measurement. The identified instruments satisfy the individual criteria to different degrees. They are increasingly being used in health services research, treatment studies, and epidemiological research; however, they are not yet widely used as part of the clinical routine in child and adolescent psychiatrics. PMID:25152654

  11. Determining procedures for simulation-based training in radiology: a nationwide needs assessment.

    PubMed

    Nayahangan, Leizl Joy; Nielsen, Kristina Rue; Albrecht-Beste, Elisabeth; Bachmann Nielsen, Michael; Paltved, Charlotte; Lindorff-Larsen, Karen Gilboe; Nielsen, Bjørn Ulrik; Konge, Lars

    2018-06-01

    New training modalities such as simulation are widely accepted in radiology; however, development of effective simulation-based training programs is challenging. They are often unstructured and based on convenience or coincidence. The study objective was to perform a nationwide needs assessment to identify and prioritize technical procedures that should be included in a simulation-based curriculum. A needs assessment using the Delphi method was completed among 91 key leaders in radiology. Round 1 identified technical procedures that radiologists should learn. Round 2 explored frequency of procedure, number of radiologists performing the procedure, risk and/or discomfort for patients, and feasibility for simulation. Round 3 was elimination and prioritization of procedures. Response rates were 67 %, 70 % and 66 %, respectively. In Round 1, 22 technical procedures were included. Round 2 resulted in pre-prioritization of procedures. In round 3, 13 procedures were included in the final prioritized list. The three highly prioritized procedures were ultrasound-guided (US) histological biopsy and fine-needle aspiration, US-guided needle puncture and catheter drainage, and basic abdominal ultrasound. A needs assessment identified and prioritized 13 technical procedures to include in a simulation-based curriculum. The list may be used as guide for development of training programs. • Simulation-based training can supplement training on patients in radiology. • Development of simulation-based training should follow a structured approach. • The CAMES Needs Assessment Formula explores needs for simulation training. • A national Delphi study identified and prioritized procedures suitable for simulation training. • The prioritized list serves as guide for development of courses in radiology.

  12. Quality assessment in head and neck oncologic surgery in a Brazilian cancer center compared with MD Anderson Cancer Center benchmarks.

    PubMed

    Lira, Renan Bezerra; de Carvalho, André Ywata; de Carvalho, Genival Barbosa; Lewis, Carol M; Weber, Randal S; Kowalski, Luiz Paulo

    2016-07-01

    Quality assessment is a major tool for evaluation of health care delivery. In head and neck surgery, the University of Texas MD Anderson Cancer Center (MD Anderson) has defined quality standards by publishing benchmarks. We conducted an analysis of 360 head and neck surgeries performed at the AC Camargo Cancer Center (AC Camargo). The procedures were stratified into low-acuity procedures (LAPs) or high-acuity procedures (HAPs) and outcome indicators where compared to MD Anderson benchmarks. In the 360 cases, there were 332 LAPs (92.2%) and 28 HAPs (7.8%). Patients with any comorbid condition had a higher incidence of negative outcome indicators (p = .005). In the LAPs, we achieved the MD Anderson benchmarks in all outcome indicators. In HAPs, the rate of surgical site infection and length of hospital stay were higher than what is established by the benchmarks. Quality assessment of head and neck surgery is possible and should be disseminated, improving effectiveness in health care delivery. © 2015 Wiley Periodicals, Inc. Head Neck 38: 1002-1007, 2016. © 2015 Wiley Periodicals, Inc.

  13. Evaluation of ride quality measurement procedures by subjective experiments using simulators

    NASA Technical Reports Server (NTRS)

    Klauder, L. T., Jr.; Clevenson, S. A.

    1975-01-01

    Since ride quality is, by definition, a matter of passenger response, there is need for a qualification procedure (QP) for establishing the degree to which any particular ride quality measurement procedure (RQMP) does correlate with passenger responses. Once established, such a QP will provide very useful guidance for optimal adjustment of the various parameters which any given RQMP contains. A QP is proposed based on use of a ride motion simulator and on test subject responses to recordings of actual vehicle motions. Test subject responses are used to determine simulator gain settings for the individual recordings such as to make all of the simulated rides equally uncomfortable to the test subjects. Simulator platform accelerations vs. time are recorded with each ride at its equal discomfort gain setting. The equal discomfort platform acceleration recordings are then digitzed.

  14. Guidelines for the processing and quality assurance of benthic invertebrate samples collected as part of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Cuffney, T.F.; Gurtz, M.E.; Meador, M.R.

    1993-01-01

    Benthic invertebrate samples are collected as part of the U.S. Geological Survey's National Water-Quality Assessment Program. This is a perennial, multidisciplinary program that integrates biological, physical, and chemical indicators of water quality to evaluate status and trends and to develop an understanding of the factors controlling observed water quality. The Program examines water quality in 60 study units (coupled ground- and surface-water systems) that encompass most of the conterminous United States and parts of Alaska and Hawaii. Study-unit teams collect and process qualitative and semi-quantitative invertebrate samples according to standardized procedures. These samples are processed (elutriated and subsampled) in the field to produce as many as four sample components: large-rare, main-body, elutriate, and split. Each sample component is preserved in 10-percent formalin, and two components, large-rare and main-body, are sent to contract laboratories for further processing. The large-rare component is composed of large invertebrates that are removed from the sample matrix during field processing and placed in one or more containers. The main-body sample component consists of the remaining sample materials (sediment, detritus, and invertebrates) and is subsampled in the field to achieve a volume of 750 milliliters or less. The remaining two sample components, elutriate and split, are used for quality-assurance and quality-control purposes. Contract laboratories are used to identify and quantify invertebrates from the large-rare and main-body sample components according to the procedures and guidelines specified within this document. These guidelines allow the use of subsampling techniques to reduce the volume of sample material processed and to facilitate identifications. These processing procedures and techniques may be modified if the modifications provide equal or greater levels of accuracy and precision. The intent of sample processing is to

  15. 42 CFR 460.140 - Additional quality assessment activities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Additional quality assessment activities. 460.140... FOR THE ELDERLY (PACE) Quality Assessment and Performance Improvement § 460.140 Additional quality assessment activities. A PACE organization must meet external quality assessment and reporting requirements...

  16. 21 CFR 106.1 - Status and applicability of the quality control procedures regulation.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION INFANT FORMULA QUALITY CONTROL PROCEDURES... infant formula meets the safety, quality, and nutrient requirements of section 412 of the act and the..., processing, and packaging of an infant formula shall render such formula adulterated under section 412(a)(1...

  17. 21 CFR 106.1 - Status and applicability of the quality control procedures regulation.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION INFANT FORMULA QUALITY CONTROL PROCEDURES... infant formula meets the safety, quality, and nutrient requirements of section 412 of the act and the..., processing, and packaging of an infant formula shall render such formula adulterated under section 412(a)(1...

  18. Indicators of the quality of general practice care of patients with chronic illness: a step towards the real involvement of patients in the assessment of the quality of care.

    PubMed Central

    Wensing, M; Grol, R; van Montfort, P; Smits, A

    1996-01-01

    OBJECTIVE--To develop a list of indicators of the general practice care of people with chronic illnesses considered important by both patients and practitioners and to identify the indicators that are considered relevant for patient assessment of health care quality. DESIGN--Qualitative study with focus group interviews and a written consensus procedure. SETTING--General practice in the Netherlands in 1993. SUBJECTS--34 patients with chronic illness, mostly members of patient organisations, and 19 general practitioners with expertise in either chronic disease management or experience with patient surveys. MAIN MEASURES--Aspects of general practice care considered important for the delivery of good quality care that emerged from focus group interviews; the relevance of evaluations of 41 aspects of care for patients explored through the written consensus procedure. Those aspects of general practice care agreed to be both important and relevant by patients and general practitioners were considered to be suitable indicators for patient assessment of the quality of care. RESULTS--Patients and general practitioners differed to some extent in their assessment of the aspects of care that they considered important for quality. They agreed that most indicators of care that related to the ¿doctor-patient relation¿ and to ¿information and support¿ were relevant and therefore suitable as indicators for patient assessment of health care quality. There was less agreement about the relevance of indicators of ¿medical and technical care,¿ ¿availability and accessibility,¿ and ¿organisation of services.¿ CONCLUSIONS--Several indicators of the quality of general practice care of patients with chronic illness were thought to be suitable for the patient assessment of healthcare quality, but other indicators were not, mainly because of reservations by general practitioners. IMPLICATIONS-- Qualitative methods can contribute to the selection of indicators for assessment of the

  19. Constructing Ecological Networks Based on Habitat Quality Assessment: A Case Study of Changzhou, China

    PubMed Central

    Gao, Yu; Ma, Lei; Liu, Jiaxun; Zhuang, Zhuzhou; Huang, Qiuhao; Li, Manchun

    2017-01-01

    Fragmentation and reduced continuity of habitat patches threaten the environment and biodiversity. Recently, ecological networks are increasingly attracting the attention of researchers as they provide fundamental frameworks for environmental protection. This study suggests a set of procedures to construct an ecological network. First, we proposed a method to construct a landscape resistance surface based on the assessment of habitat quality. Second, to analyze the effect of the resistance surface on corridor simulations, we used three methods to construct resistance surfaces: (1) the method proposed in this paper, (2) the entropy coefficient method, and (3) the expert scoring method. Then, we integrated habitat patches and resistance surfaces to identify potential corridors using graph theory. These procedures were tested in Changzhou, China. Comparing the outputs of using different resistance surfaces demonstrated that: (1) different landscape resistance surfaces contribute to how corridors are identified, but only slightly affect the assessment of the importance of habitat patches and potential corridors; (2) the resistance surface, which is constructed based on habitat quality, is more applicable to corridor simulations; and (3) the assessment of the importance of habitat patches is fundamental for ecological network optimization in the conservation of critical habitat patches and corridors. PMID:28393879

  20. Research Notes - Openness and Evolvability - Documentation Quality Assessment

    DTIC Science & Technology

    2016-08-01

    UNCLASSIFIED UNCLASSIFIED Notes – Openness and Evolvability – Documentation Quality Assessment Michael Haddy* and Adam Sbrana...Methods and Processes. This set of Research Notes focusses on Documentation Quality Assessment. This work was undertaken from the late 1990s to 2007...1 2. DOCUMENTATION QUALITY ASSESSMENT ......................................................... 1 2.1 Documentation Quality Assessment

  1. APPLICATION OF SOFTWARE QUALITY ASSURANCE CONCEPTS AND PROCEDURES TO ENVIORNMENTAL RESEARCH INVOLVING SOFTWARE DEVELOPMENT

    EPA Science Inventory

    As EPA’s environmental research expands into new areas that involve the development of software, quality assurance concepts and procedures that were originally developed for environmental data collection may not be appropriate. Fortunately, software quality assurance is a ...

  2. Water Quality Assessment and Management

    EPA Pesticide Factsheets

    Overview of Clean Water Act (CWA) restoration framework including; water quality standards, monitoring/assessment, reporting water quality status, TMDL development, TMDL implementation (point & nonpoint source control)

  3. A dynamic quality assessment tool for laparoscopic hysterectomy to measure surgical outcomes.

    PubMed

    Driessen, Sara R C; Van Zwet, Erik W; Haazebroek, Pascal; Sandberg, Evelien M; Blikkendaal, Mathijs D; Twijnstra, Andries R H; Jansen, Frank Willem

    2016-12-01

    The current health care system has an urgent need for tools to measure quality. A wide range of quality indicators have been developed in an attempt to differentiate between high-quality and low-quality health care processes. However, one of the main issues of currently used indicators is the lack of case-mix correction and improvement possibilities. Case-mix is defined as specific (patient) characteristics that are known to potentially affect (surgical) outcome. If these characteristics are not taken into consideration, comparisons of outcome among health care providers may not be valid. The objective of the study was to develop and test a quality assessment tool for laparoscopic hysterectomy, which can serve as a new outcome quality indicator. This is a prospective, international, multicenter implementation study. A web-based application was developed with 3 main goals: (1) to measure the surgeon's performance using 3 primary outcomes (blood loss, operative time, and complications); (2) to provide immediate individual feedback using cumulative observed-minus-expected graphs; and (3) to detect consistently suboptimal performance after correcting for case-mix characteristics. All gynecologists who perform laparoscopic hysterectomies were requested to register their procedures in the application. A patient safety risk factor checklist was used by the surgeon for reflection. Thereafter a prospective implementation study was performed, and the application was tested using a survey that included the System Usability Scale. A total of 2066 laparoscopic hysterectomies were registered by 81 gynecologists. Mean operative time was 100 ± 39 minutes, blood loss 127 ± 163 mL, and the complication rate 6.1%. The overall survey response rate was 75%, and the mean System Usability Scale was 76.5 ± 13.6, which indicates that the application was good to excellent. The majority of surgeons reported that the application made them more aware of their performance, the outcomes, and

  4. [Formal quality assessment of informed consent documents in 9 hospitals].

    PubMed

    Calle-Urra, J E; Parra-Hidalgo, P; Saturno-Hernández, P J; Martínez-Martínez, M J; Navarro-Moya, F J

    2013-01-01

    Informed consent forms are very important in the process of medical information. The aim of this study is to design reliable formal quality criteria of these documents and their application in the evaluation of those used in the hospitals of a regional health service. Criteria have been designed from the analysis of existing regulations, previous studies and consultation with key experts. The interobserver concordance was assessed using the kappa index. Criteria evaluation was performed on 1425 documents of 9 hospitals. A total of 19 criteria used in the evaluation of the quality of informed consent forms have been obtained. Kappa values were higher than 0,60 in 17 of them and higher than 0,52 in the other 2. The average number of defects per document was 7.6, with a high-low ratio among hospitals of 1.84. More than 90% of the documents had defects in the information on consequences and contraindications, and in about 90% it did not mention the copy to the patient. More than 60% did not comply with stating the purpose of the procedure, a statement of having understood and clarified doubts, and the treatment options. A tool has been obtained to reliably assess the formal quality of the informed consent forms. The documents assessed have a wide margin for improvement related to giving a copy to the patient, and some aspects of the specific information that patients should receive. Copyright © 2012 SECA. Published by Elsevier Espana. All rights reserved.

  5. Stress wave sorting of red maple logs for structural quality

    Treesearch

    Xiping Wang; Robert J. Ross; David W. Green; Brian Brashaw; Karl Englund; Michael Wolcott

    2004-01-01

    Existing log grading procedures in the United States make only visual assessments of log quality. These procedures do not incorporate estimates of the modulus of elasticity (MOE) of logs. It is questionable whether the visual grading procedures currently used for logs adequately assess the potential quality of structural products manufactured from them, especially...

  6. Well installation and documentation, and ground-water sampling protocols for the pilot National Water-Quality Assessment Program

    USGS Publications Warehouse

    Hardy, M.A.; Leahy, P.P.; Alley, W.M.

    1989-01-01

    Several pilot projects are being conducted as part of the National Water Quality Assessment (NAWQA) Program. The purpose of the pilot program is to test and refine concepts for a proposed full-scale program. Three of the pilot projects are specifically designed to assess groundwater. The purpose of this report is to describe the criteria that are being used in the NAWQA pilot projects for selecting and documenting wells, installing new wells, and sampling wells for different water quality constituents. Guidelines are presented for the selection of wells for sampling. Information needed to accurately document each well includes site characteristics related to the location of the well, land use near the well, and important well construction features. These guidelines ensure the consistency of the information collected and will provide comparable data for interpretive purposes. Guidelines for the installation of wells are presented and include procedures that need to be followed for preparations prior to drilling, the selection of the drilling technique and casing type, the grouting procedure, and the well-development technique. A major component of the protocols is related to water quality sampling. Tasks are identified that need to be completed prior to visiting the site for sampling. Guidelines are presented for purging the well prior t sampling, both in terms of the volume of water pumped and the chemical stability of field parameters. Guidelines are presented concerning sampler selection as related to both inorganic and organic constituents. Documentation needed to describe the measurements and observations related to sampling each well and treating and preserving the samples are also presented. Procedures are presented for the storage and shipping of water samples, equipment cleaning, and quality assurance. Quality assurance guidelines include the description of the general distribution of the various quality assurance samples (blanks, spikes, duplicates, and

  7. 42 CFR 90.3 - Procedures for requesting health assessments.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Procedures for requesting health assessments. 90.3 Section 90.3 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES HEALTH ASSESSMENTS AND HEALTH EFFECTS STUDIES OF HAZARDOUS SUBSTANCES RELEASES AND FACILITIES ADMINISTRATIVE...

  8. Portfolio Assessment and Quality Teaching

    ERIC Educational Resources Information Center

    Kim, Youb; Yazdian, Lisa Sensale

    2014-01-01

    Our article focuses on using portfolio assessment to craft quality teaching. Extant research literature on portfolio assessment suggests that the primary purpose of assessment is to serve learning, and portfolio assessments facilitate the process of making linkages among assessment, curriculum, and student learning (Asp, 2000; Bergeron, Wermuth,…

  9. Mercury analysis in hair: Comparability and quality assessment within the transnational COPHES/DEMOCOPHES project.

    PubMed

    Esteban, Marta; Schindler, Birgit Karin; Jiménez, José Antonio; Koch, Holger Martin; Angerer, Jürgen; Rosado, Montserrat; Gómez, Silvia; Casteleyn, Ludwine; Kolossa-Gehring, Marike; Becker, Kerstin; Bloemen, Louis; Schoeters, Greet; Den Hond, Elly; Sepai, Ovnair; Exley, Karen; Horvat, Milena; Knudsen, Lisbeth E; Joas, Anke; Joas, Reinhard; Aerts, Dominique; Biot, Pierre; Borošová, Daniela; Davidson, Fred; Dumitrascu, Irina; Fischer, Marc E; Grander, Margaretha; Janasik, Beata; Jones, Kate; Kašparová, Lucie; Larssen, Thorjørn; Naray, Miklos; Nielsen, Flemming; Hohenblum, Philipp; Pinto, Rui; Pirard, Catherine; Plateel, Gregory; Tratnik, Janja Snoj; Wittsiepe, Jürgen; Castaño, Argelia

    2015-08-01

    Human biomonitoring (HBM) is an effective tool for assessing actual exposure to chemicals that takes into account all routes of intake. Although hair analysis is considered to be an optimal biomarker for assessing mercury exposure, the lack of harmonization as regards sampling and analytical procedures has often limited the comparison of data at national and international level. The European-funded projects COPHES and DEMOCOPHES developed and tested a harmonized European approach to Human Biomonitoring in response to the European Environment and Health Action Plan. Herein we describe the quality assurance program (QAP) for assessing mercury levels in hair samples from more than 1800 mother-child pairs recruited in 17 European countries. To ensure the comparability of the results, standard operating procedures (SOPs) for sampling and for mercury analysis were drafted and distributed to participating laboratories. Training sessions were organized for field workers and four external quality-assessment exercises (ICI/EQUAS), followed by the corresponding web conferences, were organized between March 2011 and February 2012. ICI/EQUAS used native hair samples at two mercury concentration ranges (0.20-0.71 and 0.80-1.63) per exercise. The results revealed relative standard deviations of 7.87-13.55% and 4.04-11.31% for the low and high mercury concentration ranges, respectively. A total of 16 out of 18 participating laboratories the QAP requirements and were allowed to analyze samples from the DEMOCOPHES pilot study. Web conferences after each ICI/EQUAS revealed this to be a new and effective tool for improving analytical performance and increasing capacity building. The procedure developed and tested in COPHES/DEMOCOPHES would be optimal for application on a global scale as regards implementation of the Minamata Convention on Mercury. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Toward a perceptual image quality assessment of color quantized images

    NASA Astrophysics Data System (ADS)

    Frackiewicz, Mariusz; Palus, Henryk

    2018-04-01

    Color image quantization is an important operation in the field of color image processing. In this paper, we consider new perceptual image quality metrics for assessment of quantized images. These types of metrics, e.g. DSCSI, MDSIs, MDSIm and HPSI achieve the highest correlation coefficients with MOS during tests on the six publicly available image databases. Research was limited to images distorted by two types of compression: JPG and JPG2K. Statistical analysis of correlation coefficients based on the Friedman test and post-hoc procedures showed that the differences between the four new perceptual metrics are not statistically significant.

  11. Surface-water-quality assessment of the Kentucky River Basin, Kentucky; fixed-station network and selected water-quality data, April 1987 through August 1991

    USGS Publications Warehouse

    Griffin, M.S.; Martin, G.R.; White, K.D.

    1994-01-01

    This report describes selected data-collection activities and the associated data collected during the Kentucky River Basin pilot study of the U.S. Geological Survey's National Water-Quality Assessment Program. The data are intended to provide a nationally consistent description and improved understanding of current water quality in the basin. The data were collected at seven fixed stations that represent stream cross sections where constituent transport and water-quality trends can be evaluated. The report includes descriptions of (1) the basin; (2) the design of the fixed-station network; (3) the fixed-station sites; (4) the physical and chemical measurements; (5) the methods of sample collection, processing, and analysis; and (6) the quality-assurance and quality-control procedures. Water-quality data collected at the fixed stations during routine periodic sampling and supplemental high-flow sampling from April 1987 to August 1991 are presented.

  12. Rapid assessment procedures in injury control.

    PubMed

    Klevens, Joanne; Anderson, Mark

    2004-03-01

    Injuries are among the leading causes of death and disability worldwide. The burden caused by injuries is even greater among the poorer nations and is projected to increase. Very often the lack of technical and financial resources, as well as the urgency of the problem, preclude applying sophisticated surveillance and research methods for generating relevant information to develop effective interventions. In these settings, it is necessary to consider more rapid and less costly methods in applying the public health approach to the problem of injury prevention and control. Rapid Assessment Procedures (RAP), developed within the fields of epidemiology, anthropology and health administration, can provide valid information in a manner that is quicker, simpler, and less costly than standard data collection methods. RAP have been applied widely and successfully to infectious and chronic disease issues, but have not been used extensively, if at all, as tools in injury control. This paper describes Rapid Assessment Procedures that (1) are useful for understanding the scope of the problem and for identifying potential risk factors, (2) can assist practitioners in determining intervention priorities, (3) can provide in-depth knowledge about a specific injury-related problem, and (4) can be used in surveillance systems to monitor outcomes. Finally, the paper describes some of the caveats in using RAP.

  13. Readability and Content Assessment of Informed Consent Forms for Medical Procedures in Croatia

    PubMed Central

    Vučemilo, Luka; Borovečki, Ana

    2015-01-01

    Background High quality of informed consent form is essential for adequate information transfer between physicians and patients. Current status of medical procedure consent forms in clinical practice in Croatia specifically in terms of the readability and the content is unknown. The aim of this study was to assess the readability and the content of informed consent forms for diagnostic and therapeutic procedures used with patients in Croatia. Methods 52 informed consent forms from six Croatian hospitals on the secondary and tertiary health-care level were tested for reading difficulty using Simple Measure of Gobbledygook (SMOG) formula adjusted for Croatian language and for qualitative analysis of the content. Results The averaged SMOG grade of analyzed informed consent forms was 13.25 (SD 1.59, range 10–19). Content analysis revealed that informed consent forms included description of risks in 96% of the cases, benefits in 81%, description of procedures in 78%, alternatives in 52%, risks and benefits of alternatives in 17% and risks and benefits of not receiving treatment or undergoing procedures in 13%. Conclusions Readability of evaluated informed consent forms is not appropriate for the general population in Croatia. The content of the forms failed to include in high proportion of the cases description of alternatives, risks and benefits of alternatives, as well as risks and benefits of not receiving treatments or undergoing procedures. Data obtained from this research could help in development and improvement of informed consent forms in Croatia especially now when Croatian hospitals are undergoing the process of accreditation. PMID:26376183

  14. Microbiological monitoring for the US Geological Survey National Water-Quality Assessment Program

    USGS Publications Warehouse

    Francy, Donna S.; Myers, Donna N.; Helsel, Dennis R.

    2000-01-01

    Data to characterize the microbiological quality of the Nation?s fresh, marine, and estuarine waters are usually collected for local purposes, most often to judge compliance with standards for protection of public health in swimmable or drinkable waters. Methods and procedures vary with the objectives and practices of the parties collecting data and are continuously being developed or modified. Therefore, it is difficult to provide a nationally consistent picture of the microbial quality of the Nation?s waters. Study objectives and guidelines for a national microbiological monitoring program are outlined in this report, using the framework of the U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) program. A national program is designed to provide long-term data on the presence of microbiological pathogens and indicators in ground water and surface water to support effective water policy and management. Three major groups of waterborne pathogens affect the public health acceptability of waters in the United States?bacteria, protozoa, and viruses. Microbiological monitoring in NAWQA would be designed to assess the occurrence, distribution, and trends of pathogenic organisms and indicators in surface waters and ground waters; relate the patterns discerned to factors that help explain them; and improve our understanding of the processes that control microbiological water quality.

  15. A Self-Assessment Procedure for Use in Evaluation Training

    ERIC Educational Resources Information Center

    Stufflebeam, Daniel L.; Wingate, Lori A.

    2005-01-01

    This article describes the Self-Assessment of Program Evaluation Expertise instrument and procedure developed to help participants assess their learning gains in a 3-week evaluation institute. Participants completed the instrument in a pre- and posttest format. To reduce both the threat of embarrassment from individual results and the temptation…

  16. The clinimetric qualities of patient-assessed instruments for measuring chronic ankle instability: a systematic review.

    PubMed

    Eechaute, Christophe; Vaes, Peter; Van Aerschot, Lieve; Asman, Sara; Duquet, William

    2007-01-18

    The assessment of outcomes from the patient's perspective becomes more recognized in health care. Also in patients with chronic ankle instability, the degree of present impairments, disabilities and participation problems should be documented from the perspective of the patient. The decision about which patient-assessed instrument is most appropriate for clinical practice should be based upon systematic reviews. Only rating scales constructed for patients with acute ligament injuries were systematically reviewed in the past. The aim of this study was to review systematically the clinimetric qualities of patient-assessed instruments designed for patients with chronic ankle instability. A computerized literature search of Medline, Embase, Cinahl, Web of Science, Sport Discus and the Cochrane Controlled Trial Register was performed to identify eligible instruments. Two reviewers independently evaluated the clinimetric qualities of the selected instruments using a criteria list. The inter-observer reliability of both the selection procedure and the clinimetric evaluation was calculated using modified kappa coefficients. The inter-observer reliability of the selection procedure was excellent (k = .86). Four instruments met the eligibility criteria: the Ankle Joint Functional Assessment Tool (AJFAT), the Functional Ankle Outcome Score (FAOS), the Foot and Ankle Disability Index (FADI) and the Functional Ankle Ability Measure (FAAM). The inter-observer reliability of the quality assessment was substantial to excellent (k between .64 and .88). Test-retest reliability was demonstrated for the FAOS, the FADI and the FAAM but not for the AJFAT. The FAOS and the FAAM met the criteria for content validity and construct validity. For none of the studied instruments, the internal consistency was sufficiently demonstrated. The presence of floor- and ceiling effects was assessed for the FAOS but ceiling effects were present for all subscales. Responsiveness was demonstrated for the

  17. Assessing the safety, effectiveness, and quality of life after the STARR procedure for obstructed defecation: results of the German STARR registry.

    PubMed

    Schwandner, Oliver; Fürst, Alois

    2010-06-01

    Internal rectal prolapse and rectocele are frequent clinical findings in patients with obstructed defecation syndrome (ODS). However, there is still no evidence whether stapled transanal rectal resection (STARR) provides a safe and effective surgical option. Therefore, the German STARR registry was initiated to assess safety, effectiveness, and quality of life. The German STARR registry was designed as an interventional, prospective, multicenter audit. Primary outcomes include safety (morbidity and adverse events), effectiveness (ODS, symptom severity, and incontinence scores), and quality of life (PAC-QoL and EQ-5D) documented at baseline and at 6 and 12 months. Statistical evaluation was performed by an independent research organization of clinical epidemiology. Complete data of 379 patients (78% females, mean age 57.8 years) were entered into the registry database. Mean operative time was 40 min, mean hospitalization was 5.5 days. A total of 103 complications and adverse events were reported in 80 patients (21.1%) including staple line complications (minor bleeding, infection, or partial dehiscence; 7.1%), major bleeding (2.9%), and postsurgical stenosis (2.1%). Comparisons of ODS and symptom severity scores (SSS) demonstrated a significant reduction in ODS score between baseline (mean 11.14) and 6 months (mean 6.43), which was maintained at 12 months (mean 6.45), and SSS at preoperative and at 6- and 12-month follow-up (13.02 vs. 7.34 vs. 6.59; paired t test, p < 0.001). Significant reduction in ODS symptoms was matched by an improvement in quality of life as judged by symptom-specific PAC-QoL and generic ED-5Q (utility and visual analog scale) scores and was not associated with an impairment of incontinence score following STARR (p > 0.05). However, 11 patients (2.9%) showed de novo incontinence, and new-onset symptoms of fecal urgency were observed in 25.3% of patients. These data indicate that STARR is a safe and effective procedure. However, conclusions are

  18. [Method for the quality assessment of data collection processes in epidemiological studies].

    PubMed

    Schöne, G; Damerow, S; Hölling, H; Houben, R; Gabrys, L

    2017-10-01

    For a quantitative evaluation of primary data collection processes in epidemiological surveys based on accompaniments and observations (in the field), there is no description of test criteria and methodologies in relevant literature and thus no known application in practice. Therefore, methods need to be developed and existing procedures adapted. The aim was to identify quality-relevant developments within quality dimensions by means of inspection points (quality indicators) during the process of data collection. As a result we seek to implement and establish a methodology for the assessment of overall survey quality supplementary to standardized data analyses. Monitors detect deviations from standard primary data collection during site visits by applying standardized checklists. Quantitative results - overall and for each dimension - are obtained by numerical calculation of quality indicators. Score results are categorized and color coded. This visual prioritization indicates necessity for intervention. The results obtained give clues regarding the current quality of data collection. This allows for the identification of such sections where interventions for quality improvement are needed. In addition, process quality development can be shown over time on an intercomparable basis. This methodology for the evaluation of data collection quality can identify deviations from norms, focalize quality analyses and help trace causes for significant deviations.

  19. Performance Assessment Examples from the Quality Performance Assessment Network

    ERIC Educational Resources Information Center

    Kuriacose, Christina

    2017-01-01

    In this brief article, Christina Kuriacose provides four sample performance assessments. Spanning grade levels, these assessments are strong examples of teacher-developed performance assessments from schools within the Center for Collaborative Education's Quality Performance Assessment network. These performance tasks demonstrate the pedagogical…

  20. Assessing Weight-Related Quality of Life in Adolescents

    PubMed Central

    Kolotkin, Ronette L.; Zeller, Meg; Modi, Avani C.; Samsa, Gregory P.; Quinlan, Nicole Polanichka; Yanovski, Jack A.; Bell, Stephen K.; Maahs, David M.; de Serna, Daniela Gonzales; Roehrig, Helmut R.

    2008-01-01

    Objective The development of a new weight-related measure to assess quality of life in adolescents [Impact of Weight on Quality of Life (IWQOL)-Kids] is described. Research Methods and Procedures Using a literature search, clinical experience, and consultation with pediatric clinicians, 73 items were developed, pilot tested, and administered to 642 participants, 11 to 19 years old, recruited from weight loss programs/studies and community samples (mean z-BMI, 1.5; range, –1.2 to 3.4; mean age, 14.0; 60% female; 56% white). Participants completed the 73 items and the Pediatric Quality of Life Inventory and were weighed and measured. Results Four factors (27 items) were identified (physical comfort, body esteem, social life, and family relations), accounting for 71% of the variance. The IWQOL-Kids demonstrated excellent psychometric properties. Internal consistency coefficients ranged from 0.88 to 0.95 for scales and equaled 0.96 for total score. Convergent validity was demonstrated with strong correlations between IWQOL-Kids total score and the Pediatric Quality of Life Inventory (r = 0.76, p < 0.0001). Significant differences were found across BMI groups and between clinical and community samples, supporting the sensitivity of this measure. Participants in a weight loss camp demonstrated improved IWQOL-Kids scores, suggesting responsiveness of the IWQOL-Kids to weight loss/social support intervention. Discussion The present study provides preliminary evidence regarding the psychometric properties of the IWQOL-Kids, a weight-related quality of life measure for adolescents. Given the rise of obesity in youth, the development of a reliable and valid weight-related measure of quality of life is timely. PMID:16648616

  1. The imprecise science of evaluating scholarly performance: utilizing broad quality categories for an assessment of business and management journals.

    PubMed

    Lange, Thomas

    2006-08-01

    In a growing number of countries, government-appointed assessment panels develop ranks on the basis of the quality of scholarly outputs to apportion budgets in recognition of evaluated performance and to justify public funds for future R&D activities. When business and management journals are being grouped in broad quality categories, a recent study has noted that this procedure was placing the same journals in essentially the same categories. Drawing on journal quality categorizations by several German- and English-speaking business departments and academic associations, the author performs nonparametric tests and correlations to analyze whether this claim can be substantiated. In particular, he examines the ability of broad quality categorizations to add value to governmental, administrative, and academic decision making by withstanding the criticism traditionally levied at research quality assessments.

  2. Assessment of Reference Height Models on Quality of Tandem-X dem

    NASA Astrophysics Data System (ADS)

    Mirzaee, S.; Motagh, M.; Arefi, H.

    2015-12-01

    The aim of this study is to investigate the effect of various Global Digital Elevation Models (GDEMs) in producing high-resolution topography model using TanDEM-X (TDX) Coregistered Single Look Slant Range Complex (CoSSC) images. We selected an image acquired on Jun 12th, 2012 over Doroud region in Lorestan, west of Iran and used 4 external digital elevation models in our processing including DLR/ASI X-SAR DEM (SRTM-X, 30m resolution), ASTER GDEM Version 2 (ASTER-GDEMV2, 30m resolution), NASA SRTM Version 4 (SRTM-V4, 90m resolution), and a local photogrammetry-based DEM prepared by National Cartographic Center (NCC DEM, 10m resolution) of Iran. InSAR procedure for DEM generation was repeated four times with each of the four external height references. The quality of each external DEM was initially assessed using ICESat filtered points. Then, the quality of, each TDX-based DEM was assessed using the more precise external DEM selected in the previous step. Results showed that both local (NCC) DEM and SRTM X-band performed the best (RMSE< 9m) for TDX-DEM generation. In contrast, ASTER GDEM v2 and SRTM C-band v4 showed poorer quality.

  3. Blind image quality assessment based on aesthetic and statistical quality-aware features

    NASA Astrophysics Data System (ADS)

    Jenadeleh, Mohsen; Masaeli, Mohammad Masood; Moghaddam, Mohsen Ebrahimi

    2017-07-01

    The main goal of image quality assessment (IQA) methods is the emulation of human perceptual image quality judgments. Therefore, the correlation between objective scores of these methods with human perceptual scores is considered as their performance metric. Human judgment of the image quality implicitly includes many factors when assessing perceptual image qualities such as aesthetics, semantics, context, and various types of visual distortions. The main idea of this paper is to use a host of features that are commonly employed in image aesthetics assessment in order to improve blind image quality assessment (BIQA) methods accuracy. We propose an approach that enriches the features of BIQA methods by integrating a host of aesthetics image features with the features of natural image statistics derived from multiple domains. The proposed features have been used for augmenting five different state-of-the-art BIQA methods, which use statistical natural scene statistics features. Experiments were performed on seven benchmark image quality databases. The experimental results showed significant improvement of the accuracy of the methods.

  4. Reducing costs while maintaining quality in endovascular neurosurgical procedures.

    PubMed

    Kashlan, Osama N; Wilson, Thomas J; Chaudhary, Neeraj; Gemmete, Joseph J; Stetler, William R; Dunnick, N Reed; Thompson, B Gregory; Pandey, Aditya S

    2014-11-01

    extrapolation over a 1-year period, the 3 policy changes decreased costs by an estimated $323,561.34. Simple cost-saving policies can lead to substantial reductions in costs of neurointerventional procedures while maintaining high levels of quality and growth of services.

  5. [Quality assessment in anesthesia].

    PubMed

    Kupperwasser, B

    1996-01-01

    Quality assessment (assurance/improvement) is the set of methods used to measure and improve the delivered care and the department's performance against pre-established criteria or standards. The four stages of the self-maintained quality assessment cycle are: problem identification, problem analysis, problem correction and evaluation of corrective actions. Quality assessment is a measurable entity for which it is necessary to define and calibrate measurement parameters (indicators) from available data gathered from the hospital anaesthesia environment. Problem identification comes from the accumulation of indicators. There are four types of quality indicators: structure, process, outcome and sentinel indicators. The latter signal a quality defect, are independent of outcomes, are easier to analyse by statistical methods and closely related to processes and main targets of quality improvement. The three types of methods to analyse the problems (indicators) are: peer review, quantitative methods and risks management techniques. Peer review is performed by qualified anaesthesiologists. To improve its validity, the review process should be explicited and conclusions based on standards of practice and literature references. The quantitative methods are statistical analyses applied to the collected data and presented in a graphic format (histogram, Pareto diagram, control charts). The risks management techniques include: a) critical incident analysis establishing an objective relationship between a 'critical' event and the associated human behaviours; b) system accident analysis, based on the fact that accidents continue to occur despite safety systems and sophisticated technologies, checks of all the process components leading to the impredictable outcome and not just the human factors; c) cause-effect diagrams facilitate the problem analysis in reducing its causes to four fundamental components (persons, regulations, equipment, process). Definition and implementation

  6. Image quality assessment using deep convolutional networks

    NASA Astrophysics Data System (ADS)

    Li, Yezhou; Ye, Xiang; Li, Yong

    2017-12-01

    This paper proposes a method of accurately assessing image quality without a reference image by using a deep convolutional neural network. Existing training based methods usually utilize a compact set of linear filters for learning features of images captured by different sensors to assess their quality. These methods may not be able to learn the semantic features that are intimately related with the features used in human subject assessment. Observing this drawback, this work proposes training a deep convolutional neural network (CNN) with labelled images for image quality assessment. The ReLU in the CNN allows non-linear transformations for extracting high-level image features, providing a more reliable assessment of image quality than linear filters. To enable the neural network to take images of any arbitrary size as input, the spatial pyramid pooling (SPP) is introduced connecting the top convolutional layer and the fully-connected layer. In addition, the SPP makes the CNN robust to object deformations to a certain extent. The proposed method taking an image as input carries out an end-to-end learning process, and outputs the quality of the image. It is tested on public datasets. Experimental results show that it outperforms existing methods by a large margin and can accurately assess the image quality on images taken by different sensors of varying sizes.

  7. Data Quality Verification at STScI - Automated Assessment and Your Data

    NASA Astrophysics Data System (ADS)

    Dempsey, R.; Swade, D.; Scott, J.; Hamilton, F.; Holm, A.

    1996-12-01

    As satellite based observatories improve their ability to deliver wider varieties and more complex types of scientific data, so to does the process of analyzing and reducing these data. It becomes correspondingly imperative that Guest Observers or Archival Researchers have access to an accurate, consistent, and easily understandable summary of the quality of their data. Previously, at the STScI, an astronomer would display and examine the quality and scientific usefulness of every single observation obtained with HST. Recently, this process has undergone a major reorganization at the Institute. A major part of the new process is that the majority of data are assessed automatically with little or no human intervention. As part of routine processing in the OSS--PODPS Unified System (OPUS), the Observatory Monitoring System (OMS) observation logs, the science processing trailer file (also known as the TRL file), and the science data headers are inspected by an automated tool, AUTO_DQ. AUTO_DQ then determines if any anomalous events occurred during the observation or through processing and calibration of the data that affects the procedural quality of the data. The results are placed directly into the Procedural Data Quality (PDQ) file as a string of predefined data quality keywords and comments. These in turn are used by the Contact Scientist (CS) to check the scientific usefulness of the observations. In this manner, the telemetry stream is checked for known problems such as losses of lock, re-centerings, or degraded guiding, for example, while missing data or calibration errors are also easily flagged. If the problem is serious, the data are then queued for manual inspection by an astronomer. The success of every target acquisition is verified manually. If serious failures are confirmed, the PI and the scheduling staff are notified so that options concerning rescheduling the observations can be explored.

  8. Towards Quality Assessment in an EFL Programme

    ERIC Educational Resources Information Center

    Ali, Holi Ibrahim Holi; Al Ajmi, Ahmed Ali Saleh

    2013-01-01

    Assessment is central in education and the teaching-learning process. This study attempts to explore the perspectives and views about quality assessment among teachers of English as a Foreign Language (EFL), and to find ways of promoting quality assessment. Quantitative methodology was used to collect data. To answer the study questions, a…

  9. Quality assessment of two- and three-dimensional unstructured meshes and validation of an upwind Euler flow solver

    NASA Technical Reports Server (NTRS)

    Woodard, Paul R.; Batina, John T.; Yang, Henry T. Y.

    1992-01-01

    Quality assessment procedures are described for two-dimensional unstructured meshes. The procedures include measurement of minimum angles, element aspect ratios, stretching, and element skewness. Meshes about the ONERA M6 wing and the Boeing 747 transport configuration are generated using an advancing front method grid generation package of programs. Solutions of Euler's equations for these meshes are obtained at low angle-of-attack, transonic conditions. Results for these cases, obtained as part of a validation study demonstrate accuracy of an implicit upwind Euler solution algorithm.

  10. Assessment of Quality and Content of Online Information About Hip Arthroscopy.

    PubMed

    Ellsworth, Bridget; Patel, Hiren; Kamath, Atul F

    2016-10-01

    The purpose of this study was to assess the quality of information available to patients on the Internet when using popular search engines to search the term "hip arthroscopy." We analyzed the quality and content of information about hip arthroscopy (HA) on the first 50 websites returned by the search engines Google and Bing for the search term "hip arthroscopy." The sites were categorized by type, and quality and content were measured using the DISCERN score, along with an HA-specific content score. The HA-specific content score was used to assess each website for the presence or absence of 19 topics about HA determined to be important for a patient seeking information about the procedure. The Health on the Net Code (HONcode) status of each website was also noted. The mean DISCERN score for all websites analyzed was 39.5, considered "poor," while only 44.6% of sites were considered "fair" or "good." Governmental and nonprofit organization (NPO) websites had the highest average DISCERN score. The mean HA-specific content score was 8.6 (range, 2 to 16). The commercial website category had the highest average HA-specific content score, followed by the governmental and NPO category. Sites that bore the HONcode certification obtained significantly higher DISCERN scores than those without the certification (P = .0032) but did not obtain significantly higher HA-specific content scores. "Hip arthroscopy" is a fairly general term, and there is significant variability in the quality of HA information available online. The HONcode is useful to identify quality patient information websites; however, it is not commonly used in HA-specific websites and does not encompass all quality websites about HA. This study increases awareness of the quality of information on HA available online. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  11. The interaction of criminal procedure and outcome.

    PubMed

    Laxminarayan, Malini; Pemberton, Antony

    2014-01-01

    Procedural quality is an important aspect of crime victims' experiences in criminal proceedings and consists of different dimensions. Two of these dimensions are procedural justice (voice) and interpersonal justice (respectful treatment). Social psychological research has suggested that both voice and respectful treatment are moderated by the impact of outcomes of justice procedures on individuals' reactions. To add to this research, we extend this assertion to the criminal justice context, examining the interaction between the assessment of procedural quality and outcome favorability with victim's trust in the legal system and self-esteem. Hierarchical regression analyses reveal that voice, respectful treatment and outcome favorability are predictive of trust in the legal system and self-esteem. Further investigation reveals that being treated with respect is only related to trust in the legal system when outcome favorability is high. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. 15 CFR 990.27 - Use of assessment procedures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 3 2010-01-01 2010-01-01 false Use of assessment procedures. 990.27 Section 990.27 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE OIL POLLUTION ACT REGULATIONS...

  13. Development of a tool to support holistic generic assessment of clinical procedure skills.

    PubMed

    McKinley, Robert K; Strand, Janice; Gray, Tracey; Schuwirth, Lambert; Alun-Jones, Tom; Miller, Helen

    2008-06-01

    The challenges of maintaining comprehensive banks of valid checklists make context-specific checklists for assessment of clinical procedural skills problematic. This paper reports the development of a tool which supports generic holistic assessment of clinical procedural skills. We carried out a literature review, focus groups and non-participant observation of assessments with interview of participants, participant evaluation of a pilot objective structured clinical examination (OSCE), a national modified Delphi study with prior definitions of consensus and an OSCE. Participants were volunteers from a large acute teaching trust, a teaching primary care trust and a national sample of National Health Service staff. Results In total, 86 students, trainees and staff took part in the focus groups, observation of assessments and pilot OSCE, 252 in the Delphi study and 46 candidates and 50 assessors in the final OSCE. We developed a prototype tool with 5 broad categories amongst which were distributed 38 component competencies. There was > 70% agreement (our prior definition of consensus) at the first round of the Delphi study for inclusion of all categories and themes and no consensus for inclusion of additional categories or themes. Generalisability was 0.76. An OSCE based on the instrument has a predicted reliability of 0.79 with 12 stations and 1 assessor per station or 10 stations and 2 assessors per station. This clinical procedural skills assessment tool enables reliable assessment and has content and face validity for the assessment of clinical procedural skills. We have designated it the Leicester Clinical Procedure Assessment Tool (LCAT).

  14. GIS based procedure of cumulative environmental impact assessment.

    PubMed

    Balakrishna Reddy, M; Blah, Baiantimon

    2009-07-01

    Scale and spatial limits of impact assessment study in a GIS platform are two very important factors that could have a bearing on the genuineness and quality of impact assessment. While effect of scale has been documented and well understood, no significant study has been carried out on spatial considerations in an impact assessment study employing GIS technique. A novel technique of impact assessment demonstrable through GIS approach termed hereby as 'spatial data integrated GIS impact assessment method (SGIAM)' is narrated in this paper. The technique makes a fundamental presumption that the importance of environmental impacts is dependent, among other things, on spatial distribution of the effects of the proposed action and of the affected receptors in a study area. For each environmental component considered (e.g., air quality), impact indices are calculated through aggregation of impact indicators which are measures of the severity of the impact. The presence and spread of environmental descriptors are suitably quantified through modeling techniques and depicted. The environmental impact index is calculated from data exported from ArcINFO, thus giving significant importance to spatial data in the impact assessment exercise.

  15. CTEPP STANDARD OPERATING PROCEDURE FOR CONDUCTING INTERNAL FIELD AUDITS AND QUALITY CONTROL (SOP-2.25)

    EPA Science Inventory

    This SOP describes the method for conducting internal field audits and quality control procedures. Internal field audits will be conducted to ensure the collection of high quality data. Internal field audits will be conducted by Field Auditors (the Field QA Officer and the Field...

  16. Automatic quality assessment of planetary images

    NASA Astrophysics Data System (ADS)

    Sidiropoulos, P.; Muller, J.-P.

    2015-10-01

    A significant fraction of planetary images are corrupted beyond the point that much scientific meaning can be extracted. For example, transmission errors result in missing data which is unrecoverable. The available planetary image datasets include many such "bad data", which both occupy valuable scientific storage resources and create false impressions about planetary image availability for specific planetary objects or target areas. In this work, we demonstrate a pipeline that we have developed to automatically assess the quality of planetary images. Additionally, this method discriminates between different types of image degradation, such as low-quality originating from camera flaws or low-quality triggered by atmospheric conditions, etc. Examples of quality assessment results for Viking Orbiter imagery will be also presented.

  17. Sound quality assessment of Diesel combustion noise using in-cylinder pressure components

    NASA Astrophysics Data System (ADS)

    Payri, F.; Broatch, A.; Margot, X.; Monelletta, L.

    2009-01-01

    The combustion process in direct injection (DI) Diesel engines is an important source of noise, and it is thus the main reason why end-users could be reluctant to drive vehicles powered with this type of engine. This means that the great potential of Diesel engines for environment preservation—due to their lower consumption and the subsequent reduction of CO2 emissions—may be lost. Moreover, the advanced combustion concepts—e.g. the HCCI (homogeneous charge compression ignition)—developed to comply with forthcoming emissions legislation, while maintaining the efficiency of current engines, are expected to be noisier because they are characterized by a higher amount of premixed combustion. For this reason many efforts have been dedicated by car manufacturers in recent years to reduce the overall level and improve the sound quality of engine noise. Evaluation procedures are required, both for noise levels and sound quality, that may be integrated in the global engine development process in a timely and cost-effective manner. In previous published work, the authors proposed a novel method for the assessment of engine noise level. A similar procedure is applied in this paper to demonstrate the suitability of combustion indicators for the evaluation of engine noise quality. These indicators, which are representative of the peak velocity of fuel burning and the resonance in the combustion chamber, are well correlated with the combustion noise mark obtained from jury testing. Quite good accuracy in the prediction of the engine noise quality has been obtained with the definition of a two-component regression, which also permits the identification of the combustion process features related to the resulting noise quality, so that corrective actions may be proposed.

  18. NATIONAL WATER-QUALITY ASSESSMENT (NAWQA) PROGRAM

    EPA Science Inventory

    The National Water-Quality Assessment (NAWQA) Program is designed to describe the status and trends in the quality of the Nations ground- and surface-water resources and to provide a sound understanding of the natural and human factors that affect the quality of these resources. ...

  19. Learning Receptive Fields and Quality Lookups for Blind Quality Assessment of Stereoscopic Images.

    PubMed

    Shao, Feng; Lin, Weisi; Wang, Shanshan; Jiang, Gangyi; Yu, Mei; Dai, Qionghai

    2016-03-01

    Blind quality assessment of 3D images encounters more new challenges than its 2D counterparts. In this paper, we propose a blind quality assessment for stereoscopic images by learning the characteristics of receptive fields (RFs) from perspective of dictionary learning, and constructing quality lookups to replace human opinion scores without performance loss. The important feature of the proposed method is that we do not need a large set of samples of distorted stereoscopic images and the corresponding human opinion scores to learn a regression model. To be more specific, in the training phase, we learn local RFs (LRFs) and global RFs (GRFs) from the reference and distorted stereoscopic images, respectively, and construct their corresponding local quality lookups (LQLs) and global quality lookups (GQLs). In the testing phase, blind quality pooling can be easily achieved by searching optimal GRF and LRF indexes from the learnt LQLs and GQLs, and the quality score is obtained by combining the LRF and GRF indexes together. Experimental results on three publicly 3D image quality assessment databases demonstrate that in comparison with the existing methods, the devised algorithm achieves high consistent alignment with subjective assessment.

  20. The SERGISAI procedure for seismic risk assessment

    NASA Astrophysics Data System (ADS)

    Zonno, G.; Garcia-Fernandez, M.; Jimenez, M.J.; Menoni, S.; Meroni, F.; Petrini, V.

    The European project SERGISAI developed a computational tool where amethodology for seismic risk assessment at different geographical scales hasbeen implemented. Experts of various disciplines, including seismologists,engineers, planners, geologists, and computer scientists, co-operated in anactual multidisciplinary process to develop this tool. Standard proceduralcodes, Geographical Information Systems (GIS), and Artificial Intelligence(AI) techniques compose the whole system, that will enable the end userto carry out a complete seismic risk assessment at three geographical scales:regional, sub-regional and local. At present, single codes or models thathave been incorporated are not new in general, but the modularity of theprototype, based on a user-friendly front-end, offers potential users thepossibility of updating or replacing any code or model if desired. Theproposed procedure is a first attempt to integrate tools, codes and methodsfor assessing expected earthquake damage, and it was mainly designedto become a useful support for civil defence and land use planning agencies.Risk factors have been treated in the most suitable way for each one, interms of level of detail, kind of parameters and units of measure.Identifying various geographical scales is not a mere question of dimension;since entities to be studied correspond to areas defined by administrativeand geographical borders. The procedure was applied in the following areas:Toscana in Italy, for the regional scale, the Garfagnana area in Toscana, forthe sub-regional scale, and a part of Barcelona city, Spain, for the localscale.

  1. 36 CFR 223.197 - Civil penalty assessment procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 36 Parks, Forests, and Public Property 2 2014-07-01 2014-07-01 false Civil penalty assessment procedures. 223.197 Section 223.197 Parks, Forests, and Public Property FOREST SERVICE, DEPARTMENT OF... PRODUCTS The Forest Resources Conservation and Shortage Relief Act of 1990 Program § 223.197 Civil penalty...

  2. 43 CFR 11.33 - What types of assessment procedures are available?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... procedures: a procedure for coastal or marine environments, which incorporates the Natural Resource Damage... Lakes environments, which incorporates the Natural Resource Damage Assessment Model for Great Lakes... available? 11.33 Section 11.33 Public Lands: Interior Office of the Secretary of the Interior NATURAL...

  3. 43 CFR 11.33 - What types of assessment procedures are available?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... procedures: a procedure for coastal or marine environments, which incorporates the Natural Resource Damage... Lakes environments, which incorporates the Natural Resource Damage Assessment Model for Great Lakes... available? 11.33 Section 11.33 Public Lands: Interior Office of the Secretary of the Interior NATURAL...

  4. Standardizing Quality Assessment of Fused Remotely Sensed Images

    NASA Astrophysics Data System (ADS)

    Pohl, C.; Moellmann, J.; Fries, K.

    2017-09-01

    The multitude of available operational remote sensing satellites led to the development of many image fusion techniques to provide high spatial, spectral and temporal resolution images. The comparison of different techniques is necessary to obtain an optimized image for the different applications of remote sensing. There are two approaches in assessing image quality: 1. Quantitatively by visual interpretation and 2. Quantitatively using image quality indices. However an objective comparison is difficult due to the fact that a visual assessment is always subject and a quantitative assessment is done by different criteria. Depending on the criteria and indices the result varies. Therefore it is necessary to standardize both processes (qualitative and quantitative assessment) in order to allow an objective image fusion quality evaluation. Various studies have been conducted at the University of Osnabrueck (UOS) to establish a standardized process to objectively compare fused image quality. First established image fusion quality assessment protocols, i.e. Quality with No Reference (QNR) and Khan's protocol, were compared on varies fusion experiments. Second the process of visual quality assessment was structured and standardized with the aim to provide an evaluation protocol. This manuscript reports on the results of the comparison and provides recommendations for future research.

  5. Automatic quality assessment of apical four-chamber echocardiograms using deep convolutional neural networks

    NASA Astrophysics Data System (ADS)

    Abdi, Amir H.; Luong, Christina; Tsang, Teresa; Allan, Gregory; Nouranian, Saman; Jue, John; Hawley, Dale; Fleming, Sarah; Gin, Ken; Swift, Jody; Rohling, Robert; Abolmaesumi, Purang

    2017-02-01

    Echocardiography (echo) is the most common test for diagnosis and management of patients with cardiac condi- tions. While most medical imaging modalities benefit from a relatively automated procedure, this is not the case for echo and the quality of the final echo view depends on the competency and experience of the sonographer. It is not uncommon that the sonographer does not have adequate experience to adjust the transducer and acquire a high quality echo, which may further affect the clinical diagnosis. In this work, we aim to aid the operator during image acquisition by automatically assessing the quality of the echo and generating the Automatic Echo Score (AES). This quality assessment method is based on a deep convolutional neural network, trained in an end-to-end fashion on a large dataset of apical four-chamber (A4C) echo images. For this project, an expert car- diologist went through 2,904 A4C images obtained from independent studies and assessed their condition based on a 6-scale grading system. The scores assigned by the expert ranged from 0 to 5. The distribution of scores among the 6 levels were almost uniform. The network was then trained on 80% of the data (2,345 samples). The average absolute error of the trained model in calculating the AES was 0.8 +/- 0:72. The computation time of the GPU implementation of the neural network was estimated at 5 ms per frame, which is sufficient for real-time deployment.

  6. Risk of transmission of sporadic Creutzfeldt-Jakob disease by surgical procedures: systematic reviews and quality of evidence.

    PubMed

    López, Fernando J García; Ruiz-Tovar, María; Almazán-Isla, Javier; Alcalde-Cabero, Enrique; Calero, Miguel; de Pedro-Cuesta, Jesús

    2017-10-01

    Sporadic Creutzfeldt-Jakob disease (sCJD) is potentially transmissible to humans. This study aimed to summarise and rate the quality of the evidence of the association between surgery and sCJD. Firstly, we conducted systematic reviews and meta-analyses of case-control studies with major surgical procedures as exposures under study. To assess quality of evidence, we used the Grading of Recommendations, Assessment, Development and Evaluations (GRADE) approach. Secondly, we conducted a systematic review of sCJD case reports after sharing neurosurgical instruments. Thirteen case-control studies met the inclusion criteria for the systematic review of case-control studies. sCJD was positively associated with heart surgery, heart and vascular surgery and eye surgery, negatively associated with tonsillectomy and appendectomy, and not associated with neurosurgery or unspecified major surgery. The overall quality of evidence was rated as very low. A single case-control study with a low risk of bias found a strong association between surgery conducted more than 20 years before disease onset and sCJD. Seven cases were described as potentially transmitted by reused neurosurgical instruments. The association between surgery and sCJD remains uncertain. Measures currently recommended for preventing sCJD transmission should be strongly maintained. Future studies should focus on the potential association between sCJD and surgery undergone a long time previously.

  7. Validation of a digital mammographic unit model for an objective and highly automated clinical image quality assessment.

    PubMed

    Perez-Ponce, Hector; Daul, Christian; Wolf, Didier; Noel, Alain

    2013-08-01

    In mammography, image quality assessment has to be directly related to breast cancer indicator (e.g. microcalcifications) detectability. Recently, we proposed an X-ray source/digital detector (XRS/DD) model leading to such an assessment. This model simulates very realistic contrast-detail phantom (CDMAM) images leading to gold disc (representing microcalcifications) detectability thresholds that are very close to those of real images taken under the simulated acquisition conditions. The detection step was performed with a mathematical observer. The aim of this contribution is to include human observers into the disc detection process in real and virtual images to validate the simulation framework based on the XRS/DD model. Mathematical criteria (contrast-detail curves, image quality factor, etc.) are used to assess and to compare, from the statistical point of view, the cancer indicator detectability in real and virtual images. The quantitative results given in this paper show that the images simulated by the XRS/DD model are useful for image quality assessment in the case of all studied exposure conditions using either human or automated scoring. Also, this paper confirms that with the XRS/DD model the image quality assessment can be automated and the whole time of the procedure can be drastically reduced. Compared to standard quality assessment methods, the number of images to be acquired is divided by a factor of eight. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  8. Developing a multidisciplinary robotic surgery quality assessment program.

    PubMed

    Gonsenhauser, Iahn; Abaza, Ronney; Mekhjian, Hagop; Moffatt-Bruce, Susan D

    2012-01-01

    The objective of this study was to test the feasibility of a novel quality-improvement (QI) program designed to incorporate multiple robotic surgical sub-specialties in one health care system. A robotic surgery quality assessment program was developed by The Ohio State University College of Medicine (OSUMC) in conjunction with The Ohio State University Medical Center Quality Improvement and Operations Department. A retrospective review of cases was performed using data interrogated from the OSUMC Information Warehouse from January 2007 through August 2009. Robotic surgery cases (n=2200) were assessed for operative times, length of stay (LOS), conversions, returns to surgery, readmissions and cancellations as potential quality indicators. An actionable and reproducible framework for the quality measurement and assessment of a multidisciplinary and interdepartmental robotic surgery program was successfully completed demonstrating areas for improvement opportunities. This report supports that standard quality indicators can be applied to multiple specialties within a health care system to develop a useful quality tracking and assessment tool in the highly specialized area of robotic surgery. © 2012 National Association for Healthcare Quality.

  9. Personality Assessment in the Schools: Issues and Procedures for School Psychologists.

    ERIC Educational Resources Information Center

    Knoff, Howard M.

    1983-01-01

    A conceptual model for school-based personality assessment, methods to integrate behavioral and projective assessment procedures, and issues surrounding the use of projective tests are presented. Ways to maximize the personality assessment process for use in placement and programing decisions are suggested. (Author/DWH)

  10. Quality assessment of two- and three-dimensional unstructured meshes and validation of an upwind Euler flow solver

    NASA Technical Reports Server (NTRS)

    Woodard, Paul R.; Yang, Henry T. Y.; Batina, John T.

    1992-01-01

    Quality assessment procedures are described for two-dimensional and three-dimensional unstructured meshes. The procedures include measurement of minimum angles, element aspect ratios, stretching, and element skewness. Meshes about the ONERA M6 wing and the Boeing 747 transport configuration are generated using an advancing front method grid generation package of programs. Solutions of Euler's equations for these meshes are obtained at low angle-of-attack, transonic conditions. Results for these cases, obtained as part of a validation study demonstrate the accuracy of an implicit upwind Euler solution algorithm.

  11. Soil quality assessment using weighted fuzzy association rules

    USGS Publications Warehouse

    Xue, Yue-Ju; Liu, Shu-Guang; Hu, Yue-Ming; Yang, Jing-Feng

    2010-01-01

    Fuzzy association rules (FARs) can be powerful in assessing regional soil quality, a critical step prior to land planning and utilization; however, traditional FARs mined from soil quality database, ignoring the importance variability of the rules, can be redundant and far from optimal. In this study, we developed a method applying different weights to traditional FARs to improve accuracy of soil quality assessment. After the FARs for soil quality assessment were mined, redundant rules were eliminated according to whether the rules were significant or not in reducing the complexity of the soil quality assessment models and in improving the comprehensibility of FARs. The global weights, each representing the importance of a FAR in soil quality assessment, were then introduced and refined using a gradient descent optimization method. This method was applied to the assessment of soil resources conditions in Guangdong Province, China. The new approach had an accuracy of 87%, when 15 rules were mined, as compared with 76% from the traditional approach. The accuracy increased to 96% when 32 rules were mined, in contrast to 88% from the traditional approach. These results demonstrated an improved comprehensibility of FARs and a high accuracy of the proposed method.

  12. Institutional Consequences of Quality Assessment

    ERIC Educational Resources Information Center

    Joao Rosa, Maria; Tavares, Diana; Amaral, Alberto

    2006-01-01

    This paper analyses the opinions of Portuguese university rectors and academics on the quality assessment system and its consequences at the institutional level. The results obtained show that university staff (rectors and academics, with more of the former than the latter) held optimistic views of the positive consequences of quality assessment…

  13. Maximising Confidence in Assessment Decision-Making: A Springboard to Quality in Assessment.

    ERIC Educational Resources Information Center

    Clayton, Berwyn; Booth, Robin; Roy, Sue

    The introduction of training packages has focused attention on the quality of assessment in the Australian vocational education and training (VET) sector on the quality of assessment. For the process of mutual recognition under the Australian Recognition Framework (ARF) to work effectively, there needs to be confidence in assessment decisions made…

  14. The implementation of a quality assurance procedure for the Veterinary Services of France.

    PubMed

    Gerster, F; Guerson, N; Moreau, V; Mulnet, O; Provot, S; Salabert, C

    2003-08-01

    Due to the increasing complexity of food production systems and the concerns that these systems raise, there has been increasing demand from the general public for more State control of these processes. In France, it is the official Veterinary Services who are responsible for food safety and who must respond to these demands. The Veterinary Service is formulating a quality assurance procedure in accordance with standard EN 45004-ISO 17020, which determines the requirements that inspection bodies must follow to be recognised, at national, European and international level, as competent and reliable. As part of this procedure, the Veterinary Service will review requirements in terms of organisation, functions, qualifications and resources. The progress of inspection service orders, from their conception by the Central Administration, to their implementation by decentralised services, must be carefully managed. It is essential that service orders be implemented effectively and systematically by using recognised methods and issuing adequate inspection reports. The training and qualifications of inspectors are very important: their skills must remain up-to-date so that there is always a network of qualified staff, that is, staff who have an understanding of production processes and who have recognised competences in terms of initial training, continuous professional development and adequate experience. The quality systems implemented will only meet expectations if they are continuously monitored by means of regular evaluations. For this reason, both internal and external audits are performed. These new practices contribute to establishing a basis for the improvement of internal evaluation. In order to facilitate the implementation of a quality assurance procedure for inspection services, several tools, that are linked with the information system of the government department responsible for food, are, or will be, at the disposal of the decentralised Veterinary Services, i

  15. Principles and Practices for Quality Assurance and Quality Control

    USGS Publications Warehouse

    Jones, Berwyn E.

    1999-01-01

    Quality assurance and quality control are vital parts of highway runoff water-quality monitoring projects. To be effective, project quality assurance must address all aspects of the project, including project management responsibilities and resources, data quality objectives, sampling and analysis plans, data-collection protocols, data quality-control plans, data-assessment procedures and requirements, and project outputs. Quality control ensures that the data quality objectives are achieved as planned. The historical development and current state of the art of quality assurance and quality control concepts described in this report can be applied to evaluation of data from prior projects.

  16. Groundwater quality data from the National Water-Quality Assessment Project, May 2012 through December 2013

    USGS Publications Warehouse

    Arnold, Terri L.; Desimone, Leslie A.; Bexfield, Laura M.; Lindsey, Bruce D.; Barlow, Jeannie R.; Kulongoski, Justin T.; Musgrove, MaryLynn; Kingsbury, James A.; Belitz, Kenneth

    2016-06-20

    Groundwater-quality data were collected from 748 wells as part of the National Water-Quality Assessment Project of the U.S. Geological Survey National Water-Quality Program from May 2012 through December 2013. The data were collected from four types of well networks: principal aquifer study networks, which assess the quality of groundwater used for public water supply; land-use study networks, which assess land-use effects on shallow groundwater quality; major aquifer study networks, which assess the quality of groundwater used for domestic supply; and enhanced trends networks, which evaluate the time scales during which groundwater quality changes. Groundwater samples were analyzed for a large number of water-quality indicators and constituents, including major ions, nutrients, trace elements, volatile organic compounds, pesticides, and radionuclides. These groundwater quality data are tabulated in this report. Quality-control samples also were collected; data from blank and replicate quality-control samples are included in this report.

  17. Open source database of images DEIMOS: extension for large-scale subjective image quality assessment

    NASA Astrophysics Data System (ADS)

    Vítek, Stanislav

    2014-09-01

    DEIMOS (Database of Images: Open Source) is an open-source database of images and video sequences for testing, verification and comparison of various image and/or video processing techniques such as compression, reconstruction and enhancement. This paper deals with extension of the database allowing performing large-scale web-based subjective image quality assessment. Extension implements both administrative and client interface. The proposed system is aimed mainly at mobile communication devices, taking into account advantages of HTML5 technology; it means that participants don't need to install any application and assessment could be performed using web browser. The assessment campaign administrator can select images from the large database and then apply rules defined by various test procedure recommendations. The standard test procedures may be fully customized and saved as a template. Alternatively the administrator can define a custom test, using images from the pool and other components, such as evaluating forms and ongoing questionnaires. Image sequence is delivered to the online client, e.g. smartphone or tablet, as a fully automated assessment sequence or viewer can decide on timing of the assessment if required. Environmental data and viewing conditions (e.g. illumination, vibrations, GPS coordinates, etc.), may be collected and subsequently analyzed.

  18. Evaluation of multi-resolution satellite sensors for assessing water quality and bottom depth of Lake Garda.

    PubMed

    Giardino, Claudia; Bresciani, Mariano; Cazzaniga, Ilaria; Schenk, Karin; Rieger, Patrizia; Braga, Federica; Matta, Erica; Brando, Vittorio E

    2014-12-15

    In this study we evaluate the capabilities of three satellite sensors for assessing water composition and bottom depth in Lake Garda, Italy. A consistent physics-based processing chain was applied to Moderate Resolution Imaging Spectroradiometer (MODIS), Landsat-8 Operational Land Imager (OLI) and RapidEye. Images gathered on 10 June 2014 were corrected for the atmospheric effects with the 6SV code. The computed remote sensing reflectance (Rrs) from MODIS and OLI were converted into water quality parameters by adopting a spectral inversion procedure based on a bio-optical model calibrated with optical properties of the lake. The same spectral inversion procedure was applied to RapidEye and to OLI data to map bottom depth. In situ measurements of Rrs and of concentrations of water quality parameters collected in five locations were used to evaluate the models. The bottom depth maps from OLI and RapidEye showed similar gradients up to 7 m (r = 0.72). The results indicate that: (1) the spatial and radiometric resolutions of OLI enabled mapping water constituents and bottom properties; (2) MODIS was appropriate for assessing water quality in the pelagic areas at a coarser spatial resolution; and (3) RapidEye had the capability to retrieve bottom depth at high spatial resolution. Future work should evaluate the performance of the three sensors in different bio-optical conditions.

  19. Implementing a routine outcome assessment procedure to evaluate the quality of assistive technology service delivery for children with physical or multiple disabilities: Perceived effectiveness, social cost, and user satisfaction.

    PubMed

    Desideri, Lorenzo; Bizzarri, Martina; Bitelli, Claudio; Roentgen, Uta; Gelderblom, Gert-Jan; de Witte, Luc

    2016-01-01

    There is a lack of evidence on the effects and quality of assistive technology service delivery (ATSD). This study presents a quasi-experimental 3-months follow-up using a pre-test/post-test design aimed at evaluating outcomes of assistive technology (AT) interventions targeting children with physical and multiple disabilities. A secondary aim was to evaluate the feasibility of the follow-up assessment adopted in this study with a view to implement the procedure in routine clinical practice. Forty-five children aged 3-17 years were included. Parents were asked to complete the Individual Prioritised Problem Assessment (IPPA) for AT effectiveness; KWAZO (Kwaliteit van Zorg [Quality of Care]) and Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST) 2.0 for satisfaction with ATSD; Siva Cost Analysis Instrument (SCAI) for estimating the social cost of AT interventions. At follow-up, 25 children used the AT recommended. IPPA effect sizes ranged from 1.4 to 0.7, showing a large effect of AT interventions. Overall, parents were satisfied with ATSD, but Maintenance, Professional Services, and AT Delivery were rated not satisfactory. SCAI showed more resources spent for AT intervention compared to human assistance without technological supports. AT may be an effective intervention for children with disabilities. Issues concerning responsiveness and feasibility of the IPPA and the SCAI instruments are discussed with a view to inform routine clinical practice.

  20. Enhancing E-Learning Quality through the Application of the AKUE Procedure Model

    ERIC Educational Resources Information Center

    Bremer, C.

    2012-01-01

    The paper describes the procedure model AKUE, which aims at the improvement and assurance of quality and cost efficiency in the context of the introduction of e-learning and the development of digital learning material. AKUE divides the whole planning and implementation process into four different phases: analysis, conception, implementation, and…

  1. Assessing Assessment Quality: Criteria for Quality Assurance in Design of (Peer) Assessment for Learning--A Review of Research Studies

    ERIC Educational Resources Information Center

    Tillema, Harm; Leenknecht, Martijn; Segers, Mien

    2011-01-01

    The interest in "assessment for learning" (AfL) has resulted in a search for new modes of assessment that are better aligned to students' learning how to learn. However, with the introduction of new assessment tools, also questions arose with respect to the quality of its measurement. On the one hand, the appropriateness of traditional,…

  2. Assessing Quality in Home Visiting Programs

    ERIC Educational Resources Information Center

    Korfmacher, Jon; Laszewski, Audrey; Sparr, Mariel; Hammel, Jennifer

    2013-01-01

    Defining quality and designing a quality assessment measure for home visitation programs is a complex and multifaceted undertaking. This article summarizes the process used to create the Home Visitation Program Quality Rating Tool (HVPQRT) and identifies next steps for its development. The HVPQRT measures both structural and dynamic features of…

  3. Emotional reactivity assessment of healthy elderly with an emotion-induction procedure.

    PubMed

    Fajula, Claire; Bonin-Guillaume, Sylvie; Jouve, Elisabeth; Blin, Olivier

    2013-01-01

    BACKGROUND/STUDY CONTEXT: No emotion-induction procedure is clearly recommended to assess the emotional reactivity in the elderly. This study aimed to validate an emotional reactivity procedure in healthy old patients. Nineteen healthy elders (age range: 66-91 years old) were compared with 19 education- and sex-matched young adults (age range: 20-33 years old) using a cross-sectional design. The main outcome measure was the evaluation of emotional reactivity to commercial film excerpts used as stimuli (joy, anger, fear, sadness, disgust, or neutral state) according to Philippot's procedure and using a 5-point questionnaire assessing 10 emotion dimensions (Differential Emotions Scale, DES). In the elderly sample, targeted emotions of fear, disgust, anger, and sadness were significantly induced compared with the baseline status. The global emotional reactivity to each film showed that the elderly subjects rated the DES in the same manner as the young adults, but with significantly higher global intensity for the excerpts inducing fear, anger, disgust, and sadness. The Philippot procedure is accurate for studying emotional reactivity in healthy elderly. The simplicity and rapidity of this procedure makes it suitable for emotion studies in different elderly populations.

  4. A probabilistic seismic risk assessment procedure for nuclear power plants: (I) Methodology

    USGS Publications Warehouse

    Huang, Y.-N.; Whittaker, A.S.; Luco, N.

    2011-01-01

    A new procedure for probabilistic seismic risk assessment of nuclear power plants (NPPs) is proposed. This procedure modifies the current procedures using tools developed recently for performance-based earthquake engineering of buildings. The proposed procedure uses (a) response-based fragility curves to represent the capacity of structural and nonstructural components of NPPs, (b) nonlinear response-history analysis to characterize the demands on those components, and (c) Monte Carlo simulations to determine the damage state of the components. The use of response-rather than ground-motion-based fragility curves enables the curves to be independent of seismic hazard and closely related to component capacity. The use of Monte Carlo procedure enables the correlation in the responses of components to be directly included in the risk assessment. An example of the methodology is presented in a companion paper to demonstrate its use and provide the technical basis for aspects of the methodology. ?? 2011 Published by Elsevier B.V.

  5. Assessing Reading. Using Cloze Procedure To Assess Reading Skills. [Packet] and Handbook.

    ERIC Educational Resources Information Center

    Vaughan, Judy

    These instructor's materials consist of a handbook directed to the teacher and 33 worksheets teachers can use with adult students in order to use the cloze procedure to assess how readily they can read materials of differing complexity. The handbook introduces the materials by considering such questions as What is meant by reading?, How could…

  6. 42 CFR 493.1299 - Standard: Postanalytic systems quality assessment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Postanalytic systems quality assessment... Nonwaived Testing Postanalytic Systems § 493.1299 Standard: Postanalytic systems quality assessment. (a) The....1291. (b) The postanalytic systems quality assessment must include a review of the effectiveness of...

  7. Rating methodological quality: toward improved assessment and investigation.

    PubMed

    Moyer, Anne; Finney, John W

    2005-01-01

    Assessing methodological quality is considered essential in deciding what investigations to include in research syntheses and in detecting potential sources of bias in meta-analytic results. Quality assessment is also useful in characterizing the strengths and limitations of the research in an area of study. Although numerous instruments to measure research quality have been developed, they have lacked empirically-supported components. In addition, different summary quality scales have yielded different findings when they were used to weight treatment effect estimates for the same body of research. Suggestions for developing improved quality instruments include: distinguishing distinct domains of quality, such as internal validity, external validity, the completeness of the study report, and adherence to ethical practices; focusing on individual aspects, rather than domains of quality; and focusing on empirically-verified criteria. Other ways to facilitate the constructive use of quality assessment are to improve and standardize the reporting of research investigations, so that the quality of studies can be more equitably and thoroughly compared, and to identify optimal methods for incorporating study quality ratings into meta-analyses.

  8. 49 CFR 1540.205 - Procedures for security threat assessment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 9 2014-10-01 2014-10-01 false Procedures for security threat assessment. 1540.205 Section 1540.205 Transportation Other Regulations Relating to Transportation (Continued) TRANSPORTATION SECURITY ADMINISTRATION, DEPARTMENT OF HOMELAND SECURITY CIVIL AVIATION SECURITY CIVIL AVIATION...

  9. Quality Assessment in Oncology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Albert, Jeffrey M.; Das, Prajnan, E-mail: prajdas@mdanderson.org

    2012-07-01

    The movement to improve healthcare quality has led to a need for carefully designed quality indicators that accurately reflect the quality of care. Many different measures have been proposed and continue to be developed by governmental agencies and accrediting bodies. However, given the inherent differences in the delivery of care among medical specialties, the same indicators will not be valid across all of them. Specifically, oncology is a field in which it can be difficult to develop quality indicators, because the effectiveness of an oncologic intervention is often not immediately apparent, and the multidisciplinary nature of the field necessarily involvesmore » many different specialties. Existing and emerging comparative effectiveness data are helping to guide evidence-based practice, and the increasing availability of these data provides the opportunity to identify key structure and process measures that predict for quality outcomes. The increasing emphasis on quality and efficiency will continue to compel the medical profession to identify appropriate quality measures to facilitate quality improvement efforts and to guide accreditation, credentialing, and reimbursement. Given the wide-reaching implications of quality metrics, it is essential that they be developed and implemented with scientific rigor. The aims of the present report were to review the current state of quality assessment in oncology, identify existing indicators with the best evidence to support their implementation, and propose a framework for identifying and refining measures most indicative of true quality in oncologic care.« less

  10. 42 CFR 493.1289 - Standard: Analytic systems quality assessment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Analytic systems quality assessment. 493... Nonwaived Testing Analytic Systems § 493.1289 Standard: Analytic systems quality assessment. (a) The... through 493.1283. (b) The analytic systems quality assessment must include a review of the effectiveness...

  11. 42 CFR 493.1249 - Standard: Preanalytic systems quality assessment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Preanalytic systems quality assessment... Nonwaived Testing Preanalytic Systems § 493.1249 Standard: Preanalytic systems quality assessment. (a) The....1241 through 493.1242. (b) The preanalytic systems quality assessment must include a review of the...

  12. Should Title 24 Ventilation Requirements Be Amended to include an Indoor Air Quality Procedure?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dutton, Spencer M.; Mendell, Mark J.; Chan, Wanyu R.

    Minimum outdoor air ventilation rates (VRs) for buildings are specified in standards, including California?s Title 24 standards. The ASHRAE ventilation standard includes two options for mechanically-ventilated buildings ? a prescriptive ventilation rate procedure (VRP) that specifies minimum VRs that vary among occupancy classes, and a performance-based indoor air quality procedure (IAQP) that may result in lower VRs than the VRP, with associated energy savings, if IAQ meeting specified criteria can be demonstrated. The California Energy Commission has been considering the addition of an IAQP to the Title 24 standards. This paper, based on a review of prior data and newmore » analyses of the IAQP, evaluates four future options for Title 24: no IAQP; adding an alternate VRP, adding an equivalent indoor air quality procedure (EIAQP), and adding an improved ASHRAE-like IAQP. Criteria were established for selecting among options, and feedback was obtained in a workshop of stakeholders. Based on this review, the addition of an alternate VRP is recommended. This procedure would allow lower minimum VRs if a specified set of actions were taken to maintain acceptable IAQ. An alternate VRP could also be a valuable supplement to ASHRAE?s ventilation standard.« less

  13. Assessing quality in volcanic ash soils

    Treesearch

    Terry L. Craigg; Steven W. Howes

    2007-01-01

    Forest managers must understand how changes in soil quality resulting from project implementation affect long-term productivity and watershed health. Volcanic ash soils have unique properties that affect their quality and function; and which may warrant soil quality standards and assessment techniques that are different from other soils. We discuss the concept of soil...

  14. Critical review on the Environmental Risk Assessment of medicinal products for human use in the centralised procedure.

    PubMed

    Caneva, Laura; Bonelli, Milton; Papaluca-Amati, Marisa; Vidal, Jean-Marc

    2014-04-01

    In this article we analyse the Environmental Risk Assessment (ERA) of 59 medicinal products for human use authorised in the EU through the centralised procedure between 2011 and 2012, to establish whether company submissions are compliant with the European Medicines Agency (EMA) guideline and complete in terms of data and study reports provided. The most frequent questions raised by EU regulatory authorities are described, together with an evaluation of the presence and quality of ERA-related information in published regulatory assessment documents. The results of this review show recent improvement in ERA-related data presented in regulatory assessment documents available to the public while also highlighting a need to develop further guidance on environmental issues in order to assist applicants improve their ERA dossiers and overcome current shortcomings. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Orion Entry Handling Qualities Assessments

    NASA Technical Reports Server (NTRS)

    Bihari, B.; Tiggers, M.; Strahan, A.; Gonzalez, R.; Sullivan, K.; Stephens, J. P.; Hart, J.; Law, H., III; Bilimoria, K.; Bailey, R.

    2011-01-01

    The Orion Command Module (CM) is a capsule designed to bring crew back from the International Space Station (ISS), the moon and beyond. The atmospheric entry portion of the flight is deigned to be flown in autopilot mode for nominal situations. However, there exists the possibility for the crew to take over manual control in off-nominal situations. In these instances, the spacecraft must meet specific handling qualities criteria. To address these criteria two separate assessments of the Orion CM s entry Handling Qualities (HQ) were conducted at NASA s Johnson Space Center (JSC) using the Cooper-Harper scale (Cooper & Harper, 1969). These assessments were conducted in the summers of 2008 and 2010 using the Advanced NASA Technology Architecture for Exploration Studies (ANTARES) six degree of freedom, high fidelity Guidance, Navigation, and Control (GN&C) simulation. This paper will address the specifics of the handling qualities criteria, the vehicle configuration, the scenarios flown, the simulation background and setup, crew interfaces and displays, piloting techniques, ratings and crew comments, pre- and post-fight briefings, lessons learned and changes made to improve the overall system performance. The data collection tools, methods, data reduction and output reports will also be discussed. The objective of the 2008 entry HQ assessment was to evaluate the handling qualities of the CM during a lunar skip return. A lunar skip entry case was selected because it was considered the most demanding of all bank control scenarios. Even though skip entry is not planned to be flown manually, it was hypothesized that if a pilot could fly the harder skip entry case, then they could also fly a simpler loads managed or ballistic (constant bank rate command) entry scenario. In addition, with the evaluation set-up of multiple tasks within the entry case, handling qualities ratings collected in the evaluation could be used to assess other scenarios such as the constant bank angle

  16. A procedure for testing the quality of LANDSAT atmospheric correction algorithms

    NASA Technical Reports Server (NTRS)

    Dias, L. A. V. (Principal Investigator); Vijaykumar, N. L.; Neto, G. C.

    1982-01-01

    There are two basic methods for testing the quality of an algorithm to minimize atmospheric effects on LANDSAT imagery: (1) test the results a posteriori, using ground truth or control points; (2) use a method based on image data plus estimation of additional ground and/or atmospheric parameters. A procedure based on the second method is described. In order to select the parameters, initially the image contrast is examined for a series of parameter combinations. The contrast improves for better corrections. In addition the correlation coefficient between two subimages, taken at different times, of the same scene is used for parameter's selection. The regions to be correlated should not have changed considerably in time. A few examples using this proposed procedure are presented.

  17. Assessing the Quality of Teachers' Teaching Practices

    ERIC Educational Resources Information Center

    Chen, Weiyun; Mason, Stephen; Staniszewski, Christina; Upton, Ashley; Valley, Megan

    2012-01-01

    This study assessed the extent to which nine elementary physical education teachers implemented the quality of teaching practices. Thirty physical education lessons taught by the nine teachers to their students in grades K-5 were videotaped. Four investigators coded the taped lessons using the Assessing Quality Teaching Rubric (AQTR) designed and…

  18. [Quality of 3D magnetic resonance imaging of coronary arteries in patients with D-transposition of the great arteries after the Jatene switch procedure].

    PubMed

    Marín Rodríguez, C; Lancharro Zapata, Á; Rodríguez Ogando, A; Carrasco Muñoz, S; Ruiz Martín, Y; Sánchez Alegre, M L; Maroto Alvaro, E

    2015-01-01

    To evaluate the quality of images obtained with 3D balanced fast-field echo whole heart (WH3D) MRI sequences for assessing the coronary anastomosis and coronary stenosis in patients with D-transposition of the great arteries who have undergone the Jatene switch procedure. We retrieved 100 WH3D studies done in 83 patients who had undergone the Jatene switch procedure from our pediatric cardiac MRI database; 84 of these studies fulfilled the criteria for inclusion in the study. We evaluated coronary stenoses on WH3D MR images and their correlation with coronary CT or angiography images. We retrospectively studied the quality of the images of the proximal coronary arteries using a four-point scale and correlating the findings with age, heart rate, and heart size. Of the 84 studies, 4 (4.8%) were of a quality considered «insufficient for diagnosis», 7 (8.3%) were considered «fair», 23 (27.4%) «good», and 50 (59.5%) «excellent». The quality of the image of the coronary arteries was significantly correlated with heart rate. MRI detected stenosis in the origin of the coronary arteries in 9 (10.7%) studies. Images obtained with the WH3D MRI sequence in patients who had undergone the Jatene procedure were of diagnostic quality in most cases and were better in patients with lower heart rates. In 10.7%, stenosis in the origin of the coronary arteries that required new studies was detected. Copyright © 2014 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  19. The Midwest Stream Quality Assessment

    USGS Publications Warehouse

    ,

    2012-01-01

    In 2013, the U.S. Geological Survey (USGS) National Water-Quality Assessment Program (NAWQA) and USGS Columbia Environmental Research Center (CERC) will be collaborating with the U.S. Environmental Protection Agency (EPA) National Rivers and Streams Assessment (NRSA) to assess stream quality across the Midwestern United States. The sites selected for this study are a subset of the larger NRSA, implemented by the EPA, States and Tribes to sample flowing waters across the United States (http://water.epa.gov/type/rsl/monitoring/riverssurvey/index.cfm). The goals are to characterize water-quality stressors—contaminants, nutrients, and sediment—and ecological conditions in streams throughout the Midwest and to determine the relative effects of these stressors on aquatic organisms in the streams. Findings will contribute useful information for communities and policymakers by identifying which human and environmental factors are the most critical in controlling stream quality. This collaborative study enhances information provided to the public and policymakers and minimizes costs by leveraging and sharing data gathered under existing programs. In the spring and early summer, NAWQA will sample streams weekly for contaminants, nutrients, and sediment. During the same time period, CERC will test sediment and water samples for toxicity, deploy time-integrating samplers, and measure reproductive effects and biomarkers of contaminant exposure in fish or amphibians. NRSA will sample sites once during the summer to assess ecological and habitat conditions in the streams by collecting data on algal, macroinvertebrate, and fish communities and collecting detailed physical-habitat measurements. Study-team members from all three programs will work in collaboration with USGS Water Science Centers and State agencies on study design, execution of sampling and analysis, and reporting.

  20. Dissemination of Periodontal Pathogens in the Bloodstream after Periodontal Procedures: A Systematic Review

    PubMed Central

    Horliana, Anna Carolina Ratto Tempestini; Chambrone, Leandro; Foz, Adriana Moura; Artese, Hilana Paula Carillo; Rabelo, Mariana de Sousa; Pannuti, Cláudio Mendes; Romito, Giuseppe Alexandre

    2014-01-01

    Background To date, there is no compilation of evidence-based information associating bacteremia and periodontal procedures. This systematic review aims to assess magnitude, duration, prevalence and nature of bacteremia caused by periodontal procedures. Study Design Systematic Review Types of Studies Reviewed MEDLINE, EMBASE and LILACS databases were searched in duplicate through August, 2013 without language restriction. Observational studies were included if blood samples were collected before, during or after periodontal procedures of patients with periodontitis. The methodological quality was assessed in duplicate using the modified Newcastle-Ottawa scale (NOS). Results Search strategy identified 509 potentially eligible articles and nine were included. Only four studies demonstrated high methodological quality, whereas five were of medium or low methodological quality. The study characteristics were considered too heterogeneous to conduct a meta-analysis. Among 219 analyzed patients, 106 (49.4%) had positive bacteremia. More frequent bacteria were S. viridans, A. actinomycetemcomitans P. gingivalis, M. micros and species Streptococcus and Actinomyces, although identification methods of microbiologic assays were different among studies. Clinical Implications Although half of the patients presented positive bacteremia after periodontal procedures, accurate results regarding the magnitude, duration and nature of bacteremia could not be confidentially assessed. PMID:24870125

  1. Comparative Validity of the Shedler and Westen Assessment Procedure-200

    ERIC Educational Resources Information Center

    Mullins-Sweatt, Stephanie N.; Widiger, Thomas A.

    2008-01-01

    A predominant dimensional model of general personality structure is the five-factor model (FFM). Quite a number of alternative instruments have been developed to assess the domains of the FFM. The current study compares the validity of 2 alternative versions of the Shedler and Westen Assessment Procedure (SWAP-200) FFM scales, 1 that was developed…

  2. EQUAL-quant: an international external quality assessment scheme for real-time PCR.

    PubMed

    Ramsden, Simon C; Daly, Sarah; Geilenkeuser, Wolf-Jochen; Duncan, Graeme; Hermitte, Fabienne; Marubini, Ettore; Neumaier, Michael; Orlando, Claudio; Palicka, Vladimir; Paradiso, Angelo; Pazzagli, Mario; Pizzamiglio, Sara; Verderio, Paolo

    2006-08-01

    Quantitative gene expression analysis by real-time PCR is important in several diagnostic areas, such as the detection of minimum residual disease in leukemia and the prognostic assessment of cancer patients. To address quality assurance in this technically challenging area, the European Union (EU) has funded the EQUAL project to develop methodologic external quality assessment (EQA) relevant to diagnostic and research laboratories among the EU member states. We report here the results of the EQUAL-quant program, which assesses standards in the use of TaqMan probes, one of the most widely used assays in the implementation of real-time PCR. The EQUAL-quant reagent set was developed to assess the technical execution of a standard TaqMan assay, including RNA extraction, reverse transcription, and real-time PCR quantification of target DNA copy number. The multidisciplinary EQA scheme included 137 participating laboratories from 29 countries. We demonstrated significant differences in performance among laboratories, with 20% of laboratories reporting at least one result lacking in precision and/or accuracy according to the statistical procedures described. No differences in performance were observed for the >10 different testing platforms used by the study participants. This EQA scheme demonstrated both the requirement and demand for external assessment of technical standards in real-time PCR. The reagent design and the statistical tools developed within this project will provide a benchmark for defining acceptable working standards in this emerging technology.

  3. Performance of different mono- and multiplex nucleic acid amplification tests on a multipathogen external quality assessment panel.

    PubMed

    Loens, K; van Loon, A M; Coenjaerts, F; van Aarle, Y; Goossens, H; Wallace, P; Claas, E J C; Ieven, M

    2012-03-01

    An external quality assessment (EQA) panel consisting of a total of 48 samples in bronchoalveolar lavage (BAL) fluid or transport medium was prepared in collaboration with Quality Control for Molecular Diagnostics (QCMD) (www.qcmd.org). The panel was used to assess the proficiency of the three laboratories that would be responsible for examining the 6,000 samples to be collected in the GRACE Network of Excellence (www.grace-lrti.org). The main objective was to decide on the best-performing testing approach for the detection of influenza viruses A and B, parainfluenza virus types 1 to 3, respiratory syncytial virus (RSV), human metapneumovirus, coronavirus, rhinovirus, adenovirus, Chlamydophila pneumoniae, Mycoplasma pneumoniae, and Legionella pneumophila by nucleic acid amplification techniques (NAATs). Two approaches were chosen: (i) laboratories testing samples using their in-house procedures for extraction and amplification and (ii) laboratories using their in-house amplification procedures on centrally extracted samples. Furthermore, three commercially available multiplex NAAT tests-the ResPlex (Qiagen GmbH, Hilden, Germany), RespiFinder plus (PathoFinder, Maastricht, The Netherlands), and RespiFinder Smart 21 (PathoFinder) tests-were evaluated by examination of the same EQA panel by the manufacturer. No large differences among the 3 laboratories were noticed when the performances of the assays developed in-house in combination with the in-house extraction procedures were compared. Also, the extraction procedure (central versus local) had little effect on performance. However, large differences in amplification efficacy were found between the commercially available tests; acceptable results were obtained by using the PathoFinder assays.

  4. A procedure for NEPA assessment of selenium hazards associated with mining

    Treesearch

    Dennis A. Lemly

    2007-01-01

    This paper gives step-by-step instructions for assessing aquatic selenium hazards associated with mining. The procedure was developed to provide the U.S. Forest Service with a proactive capability for determining the risk of selenium pollution when it reviews mine permit applications in accordance with the National Environmental Policy Act (NEPA). The procedural...

  5. Assessing Pre-Service Teachers' Quality Teaching Practices

    ERIC Educational Resources Information Center

    Chen, Weiyun; Hendricks, Kristin; Archibald, Kelsi

    2011-01-01

    The purpose of this study was to design and validate the Assessing Quality Teaching Rubrics (AQTR) that assesses the pre-service teachers' quality teaching practices in a live lesson or a videotaped lesson. Twenty-one lessons taught by 13 Physical Education Teacher Education (PETE) students were videotaped. The videotaped lessons were evaluated…

  6. Knowing the operative game plan: a novel tool for the assessment of surgical procedural knowledge.

    PubMed

    Balayla, Jacques; Bergman, Simon; Ghitulescu, Gabriela; Feldman, Liane S; Fraser, Shannon A

    2012-08-01

    What is the source of inadequate performance in the operating room? Is it a lack of technical skills, poor judgment or a lack of procedural knowledge? We created a surgical procedural knowledge (SPK) assessment tool and evaluated its use. We interviewed medical students, residents and training program staff on SPK assessment tools developed for 3 different common general surgery procedures: inguinal hernia repair with mesh in men, laparoscopic cholecystectomy and right hemicolectomy. The tools were developed as a step-wise assessment of specific surgical procedures based on techniques described in a current surgical text. We compared novice (medical student to postgraduate year [PGY]-2) and expert group (PGY-3 to program staff) scores using the Mann-Whitney U test. We calculated the total SPK score and defined a cut-off score using receiver operating characteristic analysis. In all, 5 participants in 7 different training groups (n = 35) underwent an interview. Median scores for each procedure and overall SPK scores increased with experience. The median SPK for novices was 54.9 (95% confidence interval [CI] 21.6-58.8) compared with 98.05 (95% CP 94.1-100.0) for experts (p = 0.012). The SPK cut-off score of 93.1 discriminates between novice and expert surgeons. Surgical procedural knowledge can reliably be assessed using our SPK assessment tool. It can discriminate between novice and expert surgeons for common general surgical procedures. Future studies are planned to evaluate its use for more complex procedures.

  7. External quality assessment for EGFR mutations in Italy: improvements in performances over the time.

    PubMed

    Normanno, Nicola; Fenizia, Francesca; Castiglione, Francesca; Barberis, Massimo; Taddei, Gian Luigi; Truini, Mauro; De Rosa, Gaetano; Pinto, Carmine; Marchetti, Antonio

    2017-01-01

    External quality assessment (EQA) schemes are essential procedures to assess the quality level of laboratories performing molecular testing of the epidermal growth factor receptor ( EGFR ) gene in non-small cell lung cancer. The Italian Association of Medical Oncology (AIOM) and the Italian Society of Pathology (SIAPEC-IAP) organise EGFR EQA programmes to ensure that the Italian laboratories achieve the quality standard levels required. Comparing the 2011, 2013 and 2015 EGFR EQA schemes, it was possible to observe improvements in the methodologies used and the outcomes. The use of direct sequencing was reduced from 78.7% in 2011 to only 14.1% in 2015, whereas the use of pyrosequencing and real-time PCR increased. The number of rounds in which centres using direct sequencing failed was significantly higher than the number of rounds that failed using other methods, both when analysing each single scheme and when combining the three EQAs together. In 2011 and 2013, about 29% of the participants failed the first phase of the programmes, compared with the 13% of centres failing in 2015, suggesting that the switch to more sensitive and robust methods could allow to increase the percentage of good performers. Although the molecular analyses are performed with good quality in Italy, the continuous education carried out by AIOM and SIAPEC-IAP remains a fundamental tool to maintain this quality level.

  8. External quality assessment for EGFR mutations in Italy: improvements in performances over the time

    PubMed Central

    Normanno, Nicola; Fenizia, Francesca; Castiglione, Francesca; Barberis, Massimo; Taddei, Gian Luigi; Truini, Mauro; De Rosa, Gaetano; Pinto, Carmine; Marchetti, Antonio

    2017-01-01

    External quality assessment (EQA) schemes are essential procedures to assess the quality level of laboratories performing molecular testing of the epidermal growth factor receptor (EGFR) gene in non-small cell lung cancer. The Italian Association of Medical Oncology (AIOM) and the Italian Society of Pathology (SIAPEC-IAP) organise EGFR EQA programmes to ensure that the Italian laboratories achieve the quality standard levels required. Comparing the 2011, 2013 and 2015 EGFR EQA schemes, it was possible to observe improvements in the methodologies used and the outcomes. The use of direct sequencing was reduced from 78.7% in 2011 to only 14.1% in 2015, whereas the use of pyrosequencing and real-time PCR increased. The number of rounds in which centres using direct sequencing failed was significantly higher than the number of rounds that failed using other methods, both when analysing each single scheme and when combining the three EQAs together. In 2011 and 2013, about 29% of the participants failed the first phase of the programmes, compared with the 13% of centres failing in 2015, suggesting that the switch to more sensitive and robust methods could allow to increase the percentage of good performers. Although the molecular analyses are performed with good quality in Italy, the continuous education carried out by AIOM and SIAPEC-IAP remains a fundamental tool to maintain this quality level. PMID:29181190

  9. The quality of instruments to assess the process of shared decision making: A systematic review.

    PubMed

    Gärtner, Fania R; Bomhof-Roordink, Hanna; Smith, Ian P; Scholl, Isabelle; Stiggelbout, Anne M; Pieterse, Arwen H

    2018-01-01

    To inventory instruments assessing the process of shared decision making and appraise their measurement quality, taking into account the methodological quality of their validation studies. In a systematic review we searched seven databases (PubMed, Embase, Emcare, Cochrane, PsycINFO, Web of Science, Academic Search Premier) for studies investigating instruments measuring the process of shared decision making. Per identified instrument, we assessed the level of evidence separately for 10 measurement properties following a three-step procedure: 1) appraisal of the methodological quality using the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN) checklist, 2) appraisal of the psychometric quality of the measurement property using three possible quality scores, 3) best-evidence synthesis based on the number of studies, their methodological and psychometrical quality, and the direction and consistency of the results. The study protocol was registered at PROSPERO: CRD42015023397. We included 51 articles describing the development and/or evaluation of 40 shared decision-making process instruments: 16 patient questionnaires, 4 provider questionnaires, 18 coding schemes and 2 instruments measuring multiple perspectives. There is an overall lack of evidence for their measurement quality, either because validation is missing or methods are poor. The best-evidence synthesis indicated positive results for a major part of instruments for content validity (50%) and structural validity (53%) if these were evaluated, but negative results for a major part of instruments when inter-rater reliability (47%) and hypotheses testing (59%) were evaluated. Due to the lack of evidence on measurement quality, the choice for the most appropriate instrument can best be based on the instrument's content and characteristics such as the perspective that they assess. We recommend refinement and validation of existing instruments, and the use of COSMIN

  10. The quality of instruments to assess the process of shared decision making: A systematic review

    PubMed Central

    Bomhof-Roordink, Hanna; Smith, Ian P.; Scholl, Isabelle; Stiggelbout, Anne M.; Pieterse, Arwen H.

    2018-01-01

    Objective To inventory instruments assessing the process of shared decision making and appraise their measurement quality, taking into account the methodological quality of their validation studies. Methods In a systematic review we searched seven databases (PubMed, Embase, Emcare, Cochrane, PsycINFO, Web of Science, Academic Search Premier) for studies investigating instruments measuring the process of shared decision making. Per identified instrument, we assessed the level of evidence separately for 10 measurement properties following a three-step procedure: 1) appraisal of the methodological quality using the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN) checklist, 2) appraisal of the psychometric quality of the measurement property using three possible quality scores, 3) best-evidence synthesis based on the number of studies, their methodological and psychometrical quality, and the direction and consistency of the results. The study protocol was registered at PROSPERO: CRD42015023397. Results We included 51 articles describing the development and/or evaluation of 40 shared decision-making process instruments: 16 patient questionnaires, 4 provider questionnaires, 18 coding schemes and 2 instruments measuring multiple perspectives. There is an overall lack of evidence for their measurement quality, either because validation is missing or methods are poor. The best-evidence synthesis indicated positive results for a major part of instruments for content validity (50%) and structural validity (53%) if these were evaluated, but negative results for a major part of instruments when inter-rater reliability (47%) and hypotheses testing (59%) were evaluated. Conclusions Due to the lack of evidence on measurement quality, the choice for the most appropriate instrument can best be based on the instrument’s content and characteristics such as the perspective that they assess. We recommend refinement and validation of

  11. Remote Sensing Image Quality Assessment Experiment with Post-Processing

    NASA Astrophysics Data System (ADS)

    Jiang, W.; Chen, S.; Wang, X.; Huang, Q.; Shi, H.; Man, Y.

    2018-04-01

    This paper briefly describes the post-processing influence assessment experiment, the experiment includes three steps: the physical simulation, image processing, and image quality assessment. The physical simulation models sampled imaging system in laboratory, the imaging system parameters are tested, the digital image serving as image processing input are produced by this imaging system with the same imaging system parameters. The gathered optical sampled images with the tested imaging parameters are processed by 3 digital image processes, including calibration pre-processing, lossy compression with different compression ratio and image post-processing with different core. Image quality assessment method used is just noticeable difference (JND) subject assessment based on ISO20462, through subject assessment of the gathered and processing images, the influence of different imaging parameters and post-processing to image quality can be found. The six JND subject assessment experimental data can be validated each other. Main conclusions include: image post-processing can improve image quality; image post-processing can improve image quality even with lossy compression, image quality with higher compression ratio improves less than lower ratio; with our image post-processing method, image quality is better, when camera MTF being within a small range.

  12. Assessment of groundwater quality: a fusion of geochemical and geophysical information via Bayesian neural networks.

    PubMed

    Maiti, Saumen; Erram, V C; Gupta, Gautam; Tiwari, Ram Krishna; Kulkarni, U D; Sangpal, R R

    2013-04-01

    Deplorable quality of groundwater arising from saltwater intrusion, natural leaching and anthropogenic activities is one of the major concerns for the society. Assessment of groundwater quality is, therefore, a primary objective of scientific research. Here, we propose an artificial neural network-based method set in a Bayesian neural network (BNN) framework and employ it to assess groundwater quality. The approach is based on analyzing 36 water samples and inverting up to 85 Schlumberger vertical electrical sounding data. We constructed a priori model by suitably parameterizing geochemical and geophysical data collected from the western part of India. The posterior model (post-inversion) was estimated using the BNN learning procedure and global hybrid Monte Carlo/Markov Chain Monte Carlo optimization scheme. By suitable parameterization of geochemical and geophysical parameters, we simulated 1,500 training samples, out of which 50 % samples were used for training and remaining 50 % were used for validation and testing. We show that the trained model is able to classify validation and test samples with 85 % and 80 % accuracy respectively. Based on cross-correlation analysis and Gibb's diagram of geochemical attributes, the groundwater qualities of the study area were classified into following three categories: "Very good", "Good", and "Unsuitable". The BNN model-based results suggest that groundwater quality falls mostly in the range of "Good" to "Very good" except for some places near the Arabian Sea. The new modeling results powered by uncertainty and statistical analyses would provide useful constrain, which could be utilized in monitoring and assessment of the groundwater quality.

  13. Quality-assurance procedures: Method 5G determination of particulate emissions from wood heaters from a dilution tunnel sampling location

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ward, T.E.; Hartman, M.W.; Olin, R.C.

    1989-06-01

    Quality-assurance procedures are contained in this comprehensive document intended to be used as an aid for wood-heater manufacturers and testing laboratories in performing particulate matter sampling of wood heaters according to EPA protocol, Method 5G. These procedures may be used in research and development, and as an aid in auditing and certification testing. A detailed, step-by-step quality assurance guide is provided to aid in the procurement and assembly of testing apparatus, to clearly describe the procedures, and to facilitate data collection and reporting. Suggested data sheets are supplied that can be used as an aid for both recordkeeping and certificationmore » applications. Throughout the document, activity matrices are provided to serve as a summary reference. Checklists are also supplied that can be used by testing personnel. Finally, for the purposes of ensuring data quality, procedures are outlined for apparatus operation, maintenance, and traceability. These procedures combined with the detailed description of the sampling and analysis protocol will help ensure the accuracy and reliability of Method 5G emission-testing results.« less

  14. An assessment model for quality management

    NASA Astrophysics Data System (ADS)

    Völcker, Chr.; Cass, A.; Dorling, A.; Zilioli, P.; Secchi, P.

    2002-07-01

    SYNSPACE together with InterSPICE and Alenia Spazio is developing an assessment method to determine the capability of an organisation in the area of quality management. The method, sponsored by the European Space Agency (ESA), is called S9kS (SPiCE- 9000 for SPACE). S9kS is based on ISO 9001:2000 with additions from the quality standards issued by the European Committee for Space Standardization (ECSS) and ISO 15504 - Process Assessments. The result is a reference model that supports the expansion of the generic process assessment framework provided by ISO 15504 to nonsoftware areas. In order to be compliant with ISO 15504, requirements from ISO 9001 and ECSS-Q-20 and Q-20-09 have been turned into process definitions in terms of Purpose and Outcomes, supported by a list of detailed indicators such as Practices, Work Products and Work Product Characteristics. In coordination with this project, the capability dimension of ISO 15504 has been revised to be consistent with ISO 9001. As contributions from ISO 9001 and the space quality assurance standards are separable, the stripped down version S9k offers organisations in all industries an assessment model based solely on ISO 9001, and is therefore interesting to all organisations, which intend to improve their quality management system based on ISO 9001.

  15. [Cardiology quality assessment in Germany--pro and contra].

    PubMed

    von Hodenberg, E; Eder, S; Grunebaum, P; Melichercik, J

    2009-10-01

    The German National Institute for Quality in Healthcare has also developed a program of external quality assessment in the field of cardiology. Hospitals are committed to collect certain data of diagnostic coronary angiography, percutaneous coronary interventions and pacemaker implantations. If statistical abnormalities are observed a so called structured dialogue is implemented. The responsible physicians of the hospitals are asked to comment possible quality deficits. Appointed members of quality commissions examine the answers and can invite the responsible physicians for interviews or also visit the hospital. However the validity of the quality data is problematic, because audits or check-ups of quality assessment in place are lacking. Therefore the results should not be misused for a comparison or ranking of hospitals with each other. As long as the validity of the quality assessment has not been improved, the results should also not be accessible for other parties, such as health insurances. Georg Thieme Verlag KG Stuttgart, New York.

  16. 40 CFR 63.1412 - Continuous process vent applicability assessment procedures and methods.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... engineering principles, measurable process parameters, or physical or chemical laws or properties. Examples of... values, and engineering assessment control applicability assessment requirements are to be determined... by using the engineering assessment procedures in paragraph (k) of this section. (f) Volumetric flow...

  17. 40 CFR 63.1412 - Continuous process vent applicability assessment procedures and methods.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... engineering principles, measurable process parameters, or physical or chemical laws or properties. Examples of... values, and engineering assessment control applicability assessment requirements are to be determined... by using the engineering assessment procedures in paragraph (k) of this section. (f) Volumetric flow...

  18. 40 CFR 63.1412 - Continuous process vent applicability assessment procedures and methods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... engineering principles, measurable process parameters, or physical or chemical laws or properties. Examples of... values, and engineering assessment control applicability assessment requirements are to be determined... by using the engineering assessment procedures in paragraph (k) of this section. (f) Volumetric flow...

  19. 40 CFR 63.1412 - Continuous process vent applicability assessment procedures and methods.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... engineering principles, measurable process parameters, or physical or chemical laws or properties. Examples of... values, and engineering assessment control applicability assessment requirements are to be determined... by using the engineering assessment procedures in paragraph (k) of this section. (f) Volumetric flow...

  20. 40 CFR 63.1412 - Continuous process vent applicability assessment procedures and methods.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... engineering principles, measurable process parameters, or physical or chemical laws or properties. Examples of... values, and engineering assessment control applicability assessment requirements are to be determined... by using the engineering assessment procedures in paragraph (k) of this section. (f) Volumetric flow...

  1. Total Quality Management of Information System for Quality Assessment of Pesantren Using Fuzzy-SERVQUAL

    NASA Astrophysics Data System (ADS)

    Faizah, Arbiati; Syafei, Wahyul Amien; Isnanto, R. Rizal

    2018-02-01

    This research proposed a model combining an approach of Total Quality Management (TQM) and Fuzzy method of Service Quality (SERVQUAL) to asses service quality. TQM implementation was as quality management orienting on customer's satisfaction by involving all stakeholders. SERVQUAL model was used to measure quality service based on five dimensions such as tangible, reliability, responsiveness, assurance, and empathy. Fuzzy set theory was to accommodate subjectivity and ambiguity of quality assessment. Input data consisted of indicator data and quality assessment aspect. Input data was, then, processed to be service quality assessment questionnaires of Pesantren by using Fuzzy method to get service quality score. This process consisted of some steps as follows : inputting dimension and questionnaire data to data base system, filling questionnaire through system, then, system calculated fuzzification, defuzzification, gap of quality expected and received by service receivers, and calculating each dimension rating showing quality refinement priority. Rating of each quality dimension was, then, displayed at dashboard system to enable users to see information. From system having been built, it could be known that tangible dimension had the highest gap, -0.399, thus it needs to be prioritized and gets evaluation and refinement action soon.

  2. Critical Emergency Medicine Procedural Skills: A Comparative Study of Methods for Teaching and Assessment.

    ERIC Educational Resources Information Center

    Chapman, Dane M.; And Others

    Three critical procedural skills in emergency medicine were evaluated using three assessment modalities--written, computer, and animal model. The effects of computer practice and previous procedure experience on skill competence were also examined in an experimental sequential assessment design. Subjects were six medical students, six residents,…

  3. 77 FR 19591 - Assessment of Mediation and Arbitration Procedures

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-02

    ..., 1111, and 1115 [Docket No. EP 699] Assessment of Mediation and Arbitration Procedures AGENCY: Surface... STB) proposes regulations that would require parties to participate in mediation in certain types of cases and would modify its existing regulations that permit parties to engage voluntarily in mediation...

  4. Assessment methods for rehabilitation.

    PubMed

    Biefang, S; Potthoff, P

    1995-09-01

    Diagnostics and evaluation in medical rehabilitation should be based on methods that are as objective as possible. In this context quantitative methods are an important precondition. We conducted for the German Pensions Insurance Institutions (which are in charge of the medical and vocational rehabilitation of workers and employees) a survey on assessment methods for rehabilitation which included an evaluation of American literature, with the aim to indicate procedures that can be considered for adaptation in Germany and to define further research requirements. The survey identified: (1) standardized procedures and instrumented tests for the assessment of musculoskeletal, cardiopulmonary and neurophysiological function; (2) personality, intelligence, achievement, neuropsychological and alcoholism screening tests for the assessment of mental or cognitive function; (3) rating scales and self-administered questionnaires for the assessment of Activities of Daily Living and Instrumental Activities of Daily Living (ADL/IADL Scales); (4) generic profiles and indexes as well as disease-specific measures for the assessment of health-related quality of life and health status; and (5) rating scales for vocational assessment. German equivalents or German versions exist only for a part of the procedures identified. Translation and testing of Anglo-Saxon procedures should have priority over the development of new German methods. The following procedures will be taken into account: (a) instrumented tests for physical function, (b) IADL Scales, (c) generic indexes of health-related quality of life, (d) specific quality of life and health status measures for disorders of the circulatory system, metabolic system, digestive organs, respiratory tract and for cancer, and (e) vocational rating scales.

  5. Is the evidence supporting dental procedures strong? A survey of Cochrane systematic reviews in oral health.

    PubMed

    Faggion, Clovis Mariano

    2012-09-01

    Every day a large number and variety of dental procedures are performed in clinical dental practice. There is, however, no information on the overall quality of evidence supporting these procedures. The objective of this study was to assess whether several common dental procedures are based on sound evidence. All Cochrane systematic reviews (CSR) published in dentistry were surveyed. The authors' conclusions about the quality of evidence supporting a specific clinical treatment were used as the measure of outcome. The evidence was considered adequate if the authors did not clearly state the evidence was weak in the conclusions while also suggesting some evidence of the effectiveness of the therapy. Of 120 CSRs assessed, in only 26 (22.0% of the reviews) was the quality of evidence regarded as adequate for supporting clinical decisions, although some methodological limitations were identified in the full text of these reviews. Moreover, the authors of most reviews reported weak or unavailable evidence. On the basis of CSRs, the overall quality of evidence can be regarded as low or nonexistent for most of the dental procedures assessed. The information reported may guide future research. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Continuing quality improvement procedures for a clinical PACS.

    PubMed

    Andriole, K P; Gould, R G; Avrin, D E; Bazzill, T M; Yin, L; Arenson, R L

    1998-08-01

    The University of California at San Francisco (USCF) Department of Radiology currently has a clinically operational picture archiving and communication system (PACS) that is thirty-five percent filmless, with the goal of becoming seventy-five percent filmless within the year. The design and implementation of the clinical PACS has been a collaborative effort between an academic research laboratory and a commercial vendor partner. Images are digitally acquired from three computed radiography (CR) scanners, five computed tomography (CT) scanners, five magnetic resonance (MR) imagers, three digital fluoroscopic rooms, an ultrasound mini-PACS and a nuclear medicine mini-PACS. The DICOM (Digital Imaging and Communications in Medicine) standard communications protocol and image format is adhered to throughout the PACS. Images are archived in hierarchical staged fashion, on a RAID (redundant array of inexpensive disks) and on magneto-optical disk jukeboxes. The clinical PACS uses an object-oriented Oracle SQL (systems query language) database, and interfaces to the Radiology Information System using the HL7 (Health Languages 7) standard. Components are networked using a combination of switched and fast ethernet, and ATM (asynchronous transfer mode), all over fiber optics. The wide area network links six UCSF sites in San Francisco. A combination of high and medium resolution dual-monitor display stations have been placed throughout the Department of Radiology, the Emergency Department (ED) and Intensive Care Units (ICU). A continuing quality improvement (CQI) committee has been formed to facilitate the PACS installation and training, workflow modifications, quality assurance and clinical acceptance. This committee includes radiologists at all levels (resident, fellow, attending), radiology technologists, film library personnel, ED and ICU clinician end-users, and PACS team members. The CQI committee has proved vital in the creation of new management procedures, providing a

  7. 7 CFR 980.501 - Safeguard procedures for potatoes, onions, and tomatoes exempt from grade, size, quality, and...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Safeguard procedures for potatoes, onions, and....501 Safeguard procedures for potatoes, onions, and tomatoes exempt from grade, size, quality, and... imports: (1) Potatoes, onions or tomatoes for consumption by charitable institutions or distribution by...

  8. 7 CFR 980.501 - Safeguard procedures for potatoes, onions, and tomatoes exempt from grade, size, quality, and...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Safeguard procedures for potatoes, onions, and....501 Safeguard procedures for potatoes, onions, and tomatoes exempt from grade, size, quality, and maturity requirements. (a) Each person who imports: (1) Potatoes, onions or tomatoes for consumption by...

  9. 7 CFR 980.501 - Safeguard procedures for potatoes, onions, and tomatoes exempt from grade, size, quality, and...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Safeguard procedures for potatoes, onions, and....501 Safeguard procedures for potatoes, onions, and tomatoes exempt from grade, size, quality, and maturity requirements. (a) Each person who imports: (1) Potatoes, onions or tomatoes for consumption by...

  10. 7 CFR 980.501 - Safeguard procedures for potatoes, onions, and tomatoes exempt from grade, size, quality, and...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Safeguard procedures for potatoes, onions, and....501 Safeguard procedures for potatoes, onions, and tomatoes exempt from grade, size, quality, and maturity requirements. (a) Each person who imports: (1) Potatoes, onions or tomatoes for consumption by...

  11. 7 CFR 980.501 - Safeguard procedures for potatoes, onions, and tomatoes exempt from grade, size, quality, and...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Safeguard procedures for potatoes, onions, and....501 Safeguard procedures for potatoes, onions, and tomatoes exempt from grade, size, quality, and maturity requirements. (a) Each person who imports: (1) Potatoes, onions or tomatoes for consumption by...

  12. Optimized in vitro procedure for assessing the cytocompatibility of magnesium-based biomaterials.

    PubMed

    Jung, Ole; Smeets, Ralf; Porchetta, Dario; Kopp, Alexander; Ptock, Christoph; Müller, Ute; Heiland, Max; Schwade, Max; Behr, Björn; Kröger, Nadja; Kluwe, Lan; Hanken, Henning; Hartjen, Philip

    2015-09-01

    Magnesium (Mg) is a promising biomaterial for degradable implant applications that has been extensively studied in vitro and in vivo in recent years. In this study, we developed a procedure that allows an optimized and uniform in vitro assessment of the cytocompatibility of Mg-based materials while respecting the standard protocol DIN EN ISO 10993-5:2009. The mouse fibroblast line L-929 was chosen as the preferred assay cell line and MEM supplemented with 10% FCS, penicillin/streptomycin and 4mM l-glutamine as the favored assay medium. The procedure consists of (1) an indirect assessment of effects of soluble Mg corrosion products in material extracts and (2) a direct assessment of the surface compatibility in terms of cell attachment and cytotoxicity originating from active corrosion processes. The indirect assessment allows the quantification of cell-proliferation (BrdU-assay), viability (XTT-assay) as well as cytotoxicity (LDH-assay) of the mouse fibroblasts incubated with material extracts. Direct assessment visualizes cells attached to the test materials by means of live-dead staining. The colorimetric assays and the visual evaluation complement each other and the combination of both provides an optimized and simple procedure for assessing the cytocompatibility of Mg-based biomaterials in vitro. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  13. Current good manufacturing practices, quality control procedures, quality factors, notification requirements, and records and reports, for infant formula. Final rule.

    PubMed

    2014-06-10

    The Food and Drug Administration (FDA or we) is issuing a final rule that adopts, with some modifications, the interim final rule (IFR) entitled "Current Good Manufacturing Practices, Quality Control Procedures, Quality Factors, Notification Requirements, and Records and Reports, for Infant Formula'' (February 10, 2014). This final rule affirms the IFR's changes to FDA's regulations and provides additional modifications and clarifications. The final rule also responds to certain comments submitted in response to the request for comments in the IFR.

  14. A national clinical quality program for Veterans Affairs catheterization laboratories (from the Veterans Affairs clinical assessment, reporting, and tracking program).

    PubMed

    Maddox, Thomas M; Plomondon, Mary E; Petrich, Megan; Tsai, Thomas T; Gethoffer, Hans; Noonan, Gregory; Gillespie, Brian; Box, Tamara; Fihn, Stephen D; Jesse, Robert L; Rumsfeld, John S

    2014-12-01

    A "learning health care system", as outlined in a recent Institute of Medicine report, harnesses real-time clinical data to continuously measure and improve clinical care. However, most current efforts to understand and improve the quality of care rely on retrospective chart abstractions complied long after the provision of clinical care. To align more closely with the goals of a learning health care system, we present the novel design and initial results of the Veterans Affairs (VA) Clinical Assessment, Reporting, and Tracking (CART) program-a national clinical quality program for VA cardiac catheterization laboratories that harnesses real-time clinical data to support clinical care and quality-monitoring efforts. Integrated within the VA electronic health record, the CART program uses a specialized software platform to collect real-time patient and procedural data for all VA patients undergoing coronary procedures in VA catheterization laboratories. The program began in 2005 and currently contains data on 434,967 catheterization laboratory procedures, including 272,097 coronary angiograms and 86,481 percutaneous coronary interventions, performed by 801 clinicians on 246,967 patients. We present the initial data from the CART program and describe 3 quality-monitoring programs that use its unique characteristics-procedural and complications feedback to individual labs, coronary device surveillance, and major adverse event peer review. The VA CART program is a novel approach to electronic health record design that supports clinical care, quality, and safety in VA catheterization laboratories. Its approach holds promise in achieving the goals of a learning health care system. Published by Elsevier Inc.

  15. Maine Educational Assessment (MEA) Operational Procedures, March 2005 Administration.

    ERIC Educational Resources Information Center

    Maine Department of Education, 2004

    2004-01-01

    This document is intended for use in conjunction with "Policies and Procedures for Accommodations and Alternate Assessment to the MEA," and both the "MEA Principal/Test Coordinator's Manual" and the "MEA Test Administrator's Manual." The first section, Enrollment, covers the following subjects: (1) Participation of Enrolled Students; (2) Students…

  16. Acceptability of Functional Behavioral Assessment Procedures to Special Educators and School Psychologists

    ERIC Educational Resources Information Center

    O'Neill, Robert E.; Bundock, Kaitlin; Kladis, Kristin; Hawken, Leanne S.

    2015-01-01

    This survey study assessed the acceptability of a variety of functional behavioral assessment (FBA) procedures (i.e., functional assessment interviews, rating scales/questionnaires, systematic direct observations, functional analysis manipulations) to a national sample of 123 special educators and a state sample of 140 school psychologists.…

  17. Implementation of 350-2500 nm diffuse reflectance spectroscopy and High-Performance Thin-Layer Chromatography to rapidly assess manufacturing consistency and quality of cotrimoxazole tablets in Tanzania.

    PubMed

    Kaale, Eliangiringa; Hope, Samuel M; Jenkins, David; Layloff, Thomas

    2016-01-01

    To assess the quality of cotrimoxazole tablets produced by a Tanzanian manufacturer by a newly instituted quality assurance programme. Tablets underwent a diffuse reflectance spectroscopy procedure with periodic quality assessment confirmation by assay and dissolution testing using validated HPTLC techniques (including weight variation and disintegration evaluations). Based on results from the primary test methods, the first group of product was <80% compliant, whereas subsequent groups reached >99% compliance. This approach provides a model for rapidly assuring product quality of future procurements of other products that is more cost-effective than traditional pharmaceutical testing techniques. © 2015 John Wiley & Sons Ltd.

  18. Evaluative procedures to detect, characterize, and assess the severity of diabetic neuropathy.

    PubMed

    Dyck, P J

    1991-01-01

    Minimal criteria for diabetic neuropathy need to be defined and universally applied. Standardized evaluative procedures need to be agreed and normal ranges determined from healthy volunteers. Types and stages of neuropathy should be established and assessments performed on representative populations of both Type 1 and Type 2 diabetic patients. Potential minimal criteria include absent ankle reflexes and vibratory sensation, and abnormalities of nerve conduction. However, the preferred criterion is the identification of more than two statistically defined abnormalities among symptoms and deficits, nerve conduction, quantitative sensory examination or quantitative autonomic examination. Various evaluative procedures are available. Symptoms should be assessed and scores can be assigned to neurological deficits. However, assessments of nerve conduction provide the most specific, objective, sensitive, and repeatable procedures, although these may be the least meaningful. Many techniques are available for quantitative sensory examination, but are poorly standardized and normal values are not available. For quantitative autonomic examination, tests are available for the adequacy of cardiovascular and peripheral vascular reflexes and increasingly for other autonomic functions. In any assessment of nerve function the conditions should be optimized and standardized, and stimuli defined. Specific instructions should be given and normal ranges established in healthy volunteers.

  19. Comparison of quality of life between two biliary drainage procedures in laparoscopic common bile duct exploration.

    PubMed

    Xin, Ying; Zhu, Xin; Wei, Qi; Cai, Xiujun; Wang, Xianfa; Huang, Diyu

    2007-03-01

    With various kinds of minimal access surgery being introduced, quality of life must be considered as a measure of whether minimal access surgery is good or not. We evaluate the difference in quality of life using two kinds of biliary drainage procedures in laparoscopic common bile duct exploration. Forty cases of laparoscopic common bile duct exploration with cholecystectomy were studied to compare gastrointestinal quality of life index (GIQLI) preoperatively and postoperatively at two, five and sixteen weeks in two groups using different biliary drainage procedures. There was no preoperative GIQLI difference between the two groups. Cases with biliary drainage through the cystic duct achieved earlier recovery. GIQLI of all cases reached normal sixteen weeks postoperatively. Biliary drainage through the cystic duct in laparoscopic common bile duct exploration may help to improve the postoperative GIQLI in patients.

  20. European Quality--Adding to the Debate?

    ERIC Educational Resources Information Center

    Birtwistle, Tim

    1996-01-01

    Two pilot programs designed to improve and maintain quality in European higher education are described and compared: an audit of universities' procedures for quality assurance; and an assessment of programs of study, including teaching and learning, student characteristics, staff, facilities, and quality management. Both include institutional…

  1. [Validation of questionnaires to assess quality of life related to fecal incontinence in children with anorectal malformations and Hirschsprung's disease].

    PubMed

    Mathias, Arthur Loguetti; Tannuri, Ana Cristina Aoun; Ferreira, Mariana Aparecida Elisei; Santos, Maria Mercês; Tannuri, Uenis

    2016-01-01

    Surgical treatment of anorectal malformations (ARMs) and Hirschsprung's disease (HD) leads to alterations in bowel habits and fecal incontinence, with consequent quality of life impairment. The objectives were to create and validate a Questionnaire for the Fecal Incontinence Index (FII) based on the Holschneider score, as well as a Questionnaire for the Assessment of Quality of Life Related to Fecal Incontinence in Children and Adolescents (QQVCFCA), based on the Fecal Incontinence Quality of Life. The questionnaires were applied to 71 children submitted to surgical procedure, in two stages. Validity was tested by comparing the QQVCFCA and a generic quality of life questionnaire (SF-36), and between QQVCFCA and the FII. A group of 59 normal children was used as control. At two stages, 45.0% (32/71) and 42.8% (21/49) of the patients had fecal incontinence. It was observed that the QQVCFCA showed a significant correlation with the SF-36 and FII (Pearson's correlation 0.57), showing that the quality of life is directly proportional to improvement in fecal incontinence. Quality of life in patients with fecal incontinence is still globally impaired, when compared with control subjects (p<0.05, Student's t test). There were also significant differences between the results of children with ARMs and children with HD. QQVCFCA and FII are useful tools to assess the quality of life and fecal incontinence in these groups of children. Children with ARMs submitted to surgical procedure and HD have similar quality of life impairment. Copyright © 2015 Sociedade de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.

  2. Quality Assessment of Internationalised Studies: Theory and Practice

    ERIC Educational Resources Information Center

    Juknyte-Petreikiene, Inga

    2013-01-01

    The article reviews forms of higher education internationalisation at an institutional level. The relevance of theoretical background of internationalised study quality assessment is highlighted and definitions of internationalised studies quality are presented. Existing methods of assessment of higher education internationalisation are criticised…

  3. Water quality assessment with hierarchical cluster analysis based on Mahalanobis distance.

    PubMed

    Du, Xiangjun; Shao, Fengjing; Wu, Shunyao; Zhang, Hanlin; Xu, Si

    2017-07-01

    Water quality assessment is crucial for assessment of marine eutrophication, prediction of harmful algal blooms, and environment protection. Previous studies have developed many numeric modeling methods and data driven approaches for water quality assessment. The cluster analysis, an approach widely used for grouping data, has also been employed. However, there are complex correlations between water quality variables, which play important roles in water quality assessment but have always been overlooked. In this paper, we analyze correlations between water quality variables and propose an alternative method for water quality assessment with hierarchical cluster analysis based on Mahalanobis distance. Further, we cluster water quality data collected form coastal water of Bohai Sea and North Yellow Sea of China, and apply clustering results to evaluate its water quality. To evaluate the validity, we also cluster the water quality data with cluster analysis based on Euclidean distance, which are widely adopted by previous studies. The results show that our method is more suitable for water quality assessment with many correlated water quality variables. To our knowledge, it is the first attempt to apply Mahalanobis distance for coastal water quality assessment.

  4. Informatics: essential infrastructure for quality assessment and improvement in nursing.

    PubMed Central

    Henry, S B

    1995-01-01

    In recent decades there have been major advances in the creation and implementation of information technologies and in the development of measures of health care quality. The premise of this article is that informatics provides essential infrastructure for quality assessment and improvement in nursing. In this context, the term quality assessment and improvement comprises both short-term processes such as continuous quality improvement (CQI) and long-term outcomes management. This premise is supported by 1) presentation of a historical perspective on quality assessment and improvement; 2) delineation of the types of data required for quality assessment and improvement; and 3) description of the current and potential uses of information technology in the acquisition, storage, transformation, and presentation of quality data, information, and knowledge. PMID:7614118

  5. A National Needs Assessment to Identify Technical Procedures in Vascular Surgery for Simulation Based Training.

    PubMed

    Nayahangan, L J; Konge, L; Schroeder, T V; Paltved, C; Lindorff-Larsen, K G; Nielsen, B U; Eiberg, J P

    2017-04-01

    Practical skills training in vascular surgery is facing challenges because of an increased number of endovascular procedures and fewer open procedures, as well as a move away from the traditional principle of "learning by doing." This change has established simulation as a cornerstone in providing trainees with the necessary skills and competences. However, the development of simulation based programs often evolves based on available resources and equipment, reflecting convenience rather than a systematic educational plan. The objective of the present study was to perform a national needs assessment to identify the technical procedures that should be integrated in a simulation based curriculum. A national needs assessment using a Delphi process was initiated by engaging 33 predefined key persons in vascular surgery. Round 1 was a brainstorming phase to identify technical procedures that vascular surgeons should learn. Round 2 was a survey that used a needs assessment formula to explore the frequency of procedures, the number of surgeons performing each procedure, risk and/or discomfort, and feasibility for simulation based training. Round 3 involved elimination and ranking of procedures. The response rate for round 1 was 70%, with 36 procedures identified. Round 2 had a 76% response rate and resulted in a preliminary prioritised list after exploring the need for simulation based training. Round 3 had an 85% response rate; 17 procedures were eliminated, resulting in a final prioritised list of 19 technical procedures. A national needs assessment using a standardised Delphi method identified a list of procedures that are highly suitable and may provide the basis for future simulation based training programs for vascular surgeons in training. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  6. Examining the Implicit Relational Assessment Procedure: Four Preliminary Studies

    ERIC Educational Resources Information Center

    Drake, Chad E.; Kellum, Karen Kate; Wilson, Kelly G.; Luoma, Jason B.; Weinstein, Jonathan H.; Adams, Catherine H.

    2010-01-01

    The Implicit Relational Assessment Procedure (IRAP) is a relatively new measure of implicit cognition that tests cognition as relational behavior instead of an associative activity and thus may provide a more specific measure of cognitive repertoires, including those for social biases, than better known implicit measures such as the Implicit…

  7. Quality assessment tools add value.

    PubMed

    Paul, L

    1996-10-01

    The rapid evolution of the health care marketplace can be expected to continue as we move closer to the 21st Century. Externally-imposed pressures for cost reduction will increasingly be accompanied by pressure within health care organizations as risk-sharing reimbursement arrangements become more commonplace. Competitive advantage will be available to those organizations that can demonstrate objective value as defined by the cost-quality equation. The tools an organization chooses to perform quality assessment will be an important factor in its ability to demonstrate such value. Traditional quality assurance will in all likelihood continue, but the extent to which quality improvement activities are adopted by the culture of an organization may determine its ability to provide objective evidence of better health status outcomes.

  8. The Implicit Relational Assessment Procedure as a Measure of Self-Esteem

    ERIC Educational Resources Information Center

    Timko, C. Alix; England, Erica L.; Herbert, James D.; Forman, Evan M.

    2010-01-01

    Two studies were conducted to pilot the Implicit Relational Assessment Procedure (IRAP) in measuring attitudes toward the self: one related to body image specifically and another assessing the broader construct of self-esteem. Study 1 utilized the IRAP with female college students to examine self-referential beliefs regarding body image. Results…

  9. Water-Quality Assessment of the High Plains Aquifer, 1999-2004

    USGS Publications Warehouse

    McMahon, Peter B.; Dennehy, Kevin F.; Bruce, Breton W.; Gurdak, Jason J.; Qi, Sharon L.

    2007-01-01

    Water quality of the High Plains aquifer was assessed for the period 1999-2004 as part of the U.S. Geological Survey's National Water-Quality Assessment (NAWQA) Program. This effort represents the first systematic regional assessment of water quality in this nationally important aquifer. A stratified, nested group of studies was designed to assess linkages between the quality of water recharging the aquifer, the effect of transport through the hydrologic system on water quality, and the quality of the resource used for human consumption and agricultural applications. The stratified, nested design facilitated upscaling of monitoring results to unmonitored areas of the aquifer as well as upscaling of process understanding from local to regional scales.

  10. 77 FR 235 - Approval and Promulgation of Air Quality Implementation Plans; Colorado; Procedural Rules...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-04

    ... Promulgation of Air Quality Implementation Plans; Colorado; Procedural Rules; Conflicts of Interest AGENCY... its members of potential conflicts of interest. We are also reproposing approval of a portion of... federally mandate that Commission members disclose any potential conflicts of interest that arise during...

  11. 77 FR 21451 - Approval and Promulgation of Air Quality Implementation Plans; Colorado; Procedural Rules...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-10

    ... Promulgation of Air Quality Implementation Plans; Colorado; Procedural Rules; Conflicts of Interest AGENCY... potential conflicts of interest. We are also approving the remaining portion of Colorado's January 7, 2008... of potential conflicts of interest. (i) Incorporation by reference. (A) Department of Public Health...

  12. Methods for Performing Survival Curve Quality-of-Life Assessments.

    PubMed

    Sumner, Walton; Ding, Eric; Fischer, Irene D; Hagen, Michael D

    2014-08-01

    Many medical decisions involve an implied choice between alternative survival curves, typically with differing quality of life. Common preference assessment methods neglect this structure, creating some risk of distortions. Survival curve quality-of-life assessments (SQLA) were developed from Gompertz survival curves fitting the general population's survival. An algorithm was developed to generate relative discount rate-utility (DRU) functions from a standard survival curve and health state and an equally attractive alternative curve and state. A least means squared distance algorithm was developed to describe how nearly 3 or more DRU functions intersect. These techniques were implemented in a program called X-Trade and tested. SQLA scenarios can portray realistic treatment choices. A side effect scenario portrays one prototypical choice, to extend life while experiencing some loss, such as an amputation. A risky treatment scenario portrays procedures with an initial mortality risk. A time trade scenario mimics conventional time tradeoffs. Each SQLA scenario yields DRU functions with distinctive shapes, such as sigmoid curves or vertical lines. One SQLA can imply a discount rate or utility if the other value is known and both values are temporally stable. Two SQLA exercises imply a unique discount rate and utility if the inferred DRU functions intersect. Three or more SQLA results can quantify uncertainty or inconsistency in discount rate and utility estimates. Pilot studies suggested that many subjects could learn to interpret survival curves and do SQLA. SQLA confuse some people. Compared with SQLA, standard gambles quantify very low utilities more easily, and time tradeoffs are simpler for high utilities. When discount rates approach zero, time tradeoffs are as informative and easier to do than SQLA. SQLA may complement conventional utility assessment methods. © The Author(s) 2014.

  13. Quality assessment of dental health services provided at the Faculty of Dentistry, King Abdulaziz University.

    PubMed

    Hassan, Ali H; Amer, Hala A; Maghrabi, Abdulhamaid A

    2005-01-01

    The objectives of this research were to assess the quality of dental services delivered in King Abdulaziz University and highlight the necessary recommendations that would improve it. The methods used were live photographs illustrating the structure of dental services of the faculty presented in the clinic buildings, waiting places, equipments, instruments and supplies, as well as the comfort and privacy. Review of official records of the faculty for the number, qualifications and training of the dental staff and auxiliary personnel, as well as the process of care (starting from patient registration until completion of treatment). Records also demonstrated the access and utilization of services delivered in the various departments, the quality of these services and of infection control measures and procedures. The results revealed the high quality of services delivered through evaluating the structure and process of care in the university dental clinics. Dental services of King Abdulaziz University conform to high quality standards, with implementation of some changes for improvement and development.

  14. An operational procedure for rapid flood risk assessment in Europe

    NASA Astrophysics Data System (ADS)

    Dottori, Francesco; Kalas, Milan; Salamon, Peter; Bianchi, Alessandra; Alfieri, Lorenzo; Feyen, Luc

    2017-07-01

    The development of methods for rapid flood mapping and risk assessment is a key step to increase the usefulness of flood early warning systems and is crucial for effective emergency response and flood impact mitigation. Currently, flood early warning systems rarely include real-time components to assess potential impacts generated by forecasted flood events. To overcome this limitation, this study describes the benchmarking of an operational procedure for rapid flood risk assessment based on predictions issued by the European Flood Awareness System (EFAS). Daily streamflow forecasts produced for major European river networks are translated into event-based flood hazard maps using a large map catalogue derived from high-resolution hydrodynamic simulations. Flood hazard maps are then combined with exposure and vulnerability information, and the impacts of the forecasted flood events are evaluated in terms of flood-prone areas, economic damage and affected population, infrastructures and cities.An extensive testing of the operational procedure has been carried out by analysing the catastrophic floods of May 2014 in Bosnia-Herzegovina, Croatia and Serbia. The reliability of the flood mapping methodology is tested against satellite-based and report-based flood extent data, while modelled estimates of economic damage and affected population are compared against ground-based estimations. Finally, we evaluate the skill of risk estimates derived from EFAS flood forecasts with different lead times and combinations of probabilistic forecasts. Results highlight the potential of the real-time operational procedure in helping emergency response and management.

  15. [Quality of health care, accreditation, and health technology assessment in Croatia: role of agency for quality and accreditation in health].

    PubMed

    Mittermayer, Renato; Huić, Mirjana; Mestrović, Josipa

    2010-12-01

    Avedis Donabedian defined the quality of care as the kind of care, which is expected to maximize an inclusive measure of patient welfare, after taking into account the balance of expected gains and losses associated with the process of care in all its segments. According to the World Medical Assembly, physicians and health care institutions have an ethical and professional obligation to strive for continuous quality improvement of services and patient safety with the ultimate goal to improve both individual patient outcomes as well as population health. Health technology assessment (HTA) is a multidisciplinary process that summarizes information about the medical, social, economic and ethical issues related to the use of a health technology in a systematic, transparent, unbiased, robust manner, with the aim to formulate safe and effective health policies that are patient focused and seek to achieve the highest value. The Agency for Quality and Accreditation in Health was established in 2007 as a legal, public, independent, nonprofit institution under the Act on Quality of Health Care. The Agency has three departments: Department of Quality and Education, Department of Accreditation, and Department of Development, Research, and Health Technology Assessment. According to the Act, the Agency should provide the procedure of granting, renewal and cancellation of accreditation of healthcare providers; proposing to the Minister, in cooperation with professional associations, the plan and program for healthcare quality assurance, improvement, promotion and monitoring; proposing the healthcare quality standards as well as the accreditation standards to the Minister; keeping a register of accreditations and providing a database related to accreditation, healthcare quality improvement, and education; providing education in the field of healthcare quality assurance, improvement and promotion; providing the HTA procedure and HTA database, supervising the healthcare insurance

  16. Characteristics of a New X-Ray Imaging System for Interventional Procedures: Improved Image Quality and Reduced Radiation Dose.

    PubMed

    Schernthaner, Ruediger E; Haroun, Reham R; Nguyen, Sonny; Duran, Rafael; Sohn, Jae Ho; Sahu, Sonia; Chapiro, Julius; Zhao, Yan; Radaelli, Alessandro; van der Bom, Imramsjah M; Mauti, Maria; Hong, Kelvin; Geschwind, Jean-François H; Lin, MingDe

    2018-03-01

    To compare image quality and radiation exposure between a new angiographic imaging system and the preceding generation system during uterine artery embolization (UAE). In this retrospective, IRB-approved two-arm study, 54 patients with symptomatic uterine fibroids were treated with UAE on two different angiographic imaging systems. The new system includes optimized acquisition parameters and real-time image processing algorithms. Air kerma (AK), dose area product (DAP) and acquisition time for digital fluoroscopy (DF) and digital subtraction angiography (DSA) were recorded. Body mass index was noted as well. DF image quality was assessed objectively by image noise measurements. DSA image quality was rated by two blinded, independent readers on a four-rank scale. Statistical differences were assessed with unpaired t tests and Wilcoxon rank-sum tests. There was no significant difference between the patients treated on the new (n = 36) and the old system (n = 18) regarding age (p = 0.10), BMI (p = 0.18), DF time (p = 0.35) and DSA time (p = 0.17). The new system significantly reduced the cumulative AK and DAP by 64 and 72%, respectively (median 0.58 Gy and 145.9 Gy*cm 2 vs. 1.62 Gy and 526.8 Gy*cm 2 , p < 0.01 for both). Specifically, DAP for DF and DSA decreased by 59% (75.3 vs. 181.9 Gy*cm 2 , p < 0.01) and 78% (67.6 vs. 312.2 Gy*cm 2 , p < 0.01), respectively. The new system achieved a significant decrease in DF image noise (p < 0.01) and a significantly better DSA image quality (p < 0.01). The new angiographic imaging system significantly improved image quality and reduced radiation exposure during UAE procedures.

  17. Assessment of Conventional Teaching Procedures: Implications for Gifted Learners

    ERIC Educational Resources Information Center

    Alenizi, Mogbel Aid K.

    2016-01-01

    The present research aims to assess the conventional teaching procedures in the development of mathematical skills of the students with learning difficulties. The study group was made up of all the children with academic learning disorders in KSA. The research questions have been scrutinized from the averages and the standard deviation of the…

  18. Recent Developments in Assessment Procedures in England and Wales.

    ERIC Educational Resources Information Center

    Goldstein, Harvey; Nuttall, Desmond

    Focusing on technical issues, this paper critiques proposed changes in assessment procedures at the further educational level (ages 16 through 18) in England and Wales. Major structural changes are taking place at this educational level, partly because of large scale youth unemployment. The two current examination systems for the final year of…

  19. Innovative Approaches to Increasing the Student Assessment Procedures Effectiveness

    ERIC Educational Resources Information Center

    Dorozhkin, Evgenij M.; Chelyshkova, Marina B.; Malygin, Alexey A.; Toymentseva, Irina A.; Anopchenko, Tatiana Y.

    2016-01-01

    The relevance of the investigated problem is determined by the need to improving the evaluation procedures in education and the student assessment in the age of the context of education widening, new modes of study developing (such as blending learning, e-learning, massive open online courses), immediate feedback necessity, reliable and valid…

  20. Performance of a quality assurance program for assessing dental health in methamphetamine users.

    PubMed

    Dye, Bruce A; Harrell, Lauren; Murphy, Debra A; Belin, Thomas; Shetty, Vivek

    2015-07-05

    site examiners was low (Kappa 0.27-0.67). Overall, the quality assurance program confirmed the procedural adherence of the quality of the data collected on the distribution of dental caries and periodontal disease in MA-users. Examiner concordance was higher for dental caries but lower for specific periodontal assessments.

  1. Methodological Quality Assessment of Meta-Analyses of Hyperthyroidism Treatment.

    PubMed

    Qin, Yahong; Yao, Liang; Shao, Feifei; Yang, Kehu; Tian, Limin

    2018-01-01

    Hyperthyroidism is a common condition that is associated with increased morbidity and mortality. A number of meta-analyses (MAs) have assessed the therapeutic measures for hyperthyroidism, including antithyroid drugs, surgery, and radioiodine, however, the methodological quality has not been evaluated. This study evaluated the methodological quality and summarized the evidence obtained from MAs of hyperthyroidism treatments for radioiodine, antithyroid drugs, and surgery. We searched the PubMed, EMBASE, Cochrane Library, Web of Science, and Chinese Biomedical Literature Database databases. Two investigators independently assessed the meta-analyses titles and abstracts for inclusion. Methodological quality was assessed using the validated AMSTAR (Assessing the Methodological Quality of Systematic Reviews) tool. A total of 26 MAs fulfilled the inclusion criteria. Based on the AMSTAR scores, the average methodological quality was 8.31, with large variability ranging from 4 to 11. The methodological quality of English meta-analyses was better than that of Chinese meta-analyses. Cochrane reviews had better methodological quality than non-Cochrane reviews due to better study selection and data extraction, the inclusion of unpublished studies, and better reporting of study characteristics. The authors did not report conflicts of interest in 53.8% meta-analyses, and 19.2% did not report the harmful effects of treatment. Publication bias was not assessed in 38.5% of meta-analyses, and 19.2% did not report the follow-up time. Large-scale assessment of methodological quality of meta-analyses of hyperthyroidism treatment highlighted methodological strengths and weaknesses. Consideration of scientific quality when formulating conclusions should be made explicit. Future meta-analyses should improve on reporting conflict of interest. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Body Disfigurement and the Quality of Life of Adolescents with Pectus Excavatum: Effects of the Nuss Procedure

    ERIC Educational Resources Information Center

    Roberts, Jillian; MacMath, Sheryl; English, Margot; Martin, Joan; Hayashi, Al; Sigalet, David L.

    2006-01-01

    This article takes a comprehensive look at the effects of pectus excavatum, a congenital deformity with psychosocial and physical ramifications, and the Nuss procedure on the quality of life of adolescents. The Nuss procedure is a minimally invasive corrective surgery. Twenty-five participants from Calgary, Alberta were interviewed (10 adolescents…

  3. MASQOT: a method for cDNA microarray spot quality control

    PubMed Central

    Bylesjö, Max; Eriksson, Daniel; Sjödin, Andreas; Sjöström, Michael; Jansson, Stefan; Antti, Henrik; Trygg, Johan

    2005-01-01

    Background cDNA microarray technology has emerged as a major player in the parallel detection of biomolecules, but still suffers from fundamental technical problems. Identifying and removing unreliable data is crucial to prevent the risk of receiving illusive analysis results. Visual assessment of spot quality is still a common procedure, despite the time-consuming work of manually inspecting spots in the range of hundreds of thousands or more. Results A novel methodology for cDNA microarray spot quality control is outlined. Multivariate discriminant analysis was used to assess spot quality based on existing and novel descriptors. The presented methodology displays high reproducibility and was found superior in identifying unreliable data compared to other evaluated methodologies. Conclusion The proposed methodology for cDNA microarray spot quality control generates non-discrete values of spot quality which can be utilized as weights in subsequent analysis procedures as well as to discard spots of undesired quality using the suggested threshold values. The MASQOT approach provides a consistent assessment of spot quality and can be considered an alternative to the labor-intensive manual quality assessment process. PMID:16223442

  4. Medicare's Hospital Compare quality reports appear to have slowed price increases for two major procedures.

    PubMed

    Dor, Avi; Encinosa, William E; Carey, Kathleen

    2015-01-01

    Previous research has found that Hospital Compare, Medicare's public reporting initiative, has had little impact on patient outcomes. However, little is known about the initiative's impact on hospital prices, which may be significant because private insurers are generally well positioned to respond to quality information when negotiating prices with hospitals. We estimated difference-in-differences models of the effects of Hospital Compare quality reporting on transaction prices for two major cardiac procedures, coronary artery bypass graft (CABG) and percutaneous coronary intervention (PCI). States that had mandated their own public reporting systems before the implementation of Hospital Compare formed the control group. We found that prices for these procedures continued to increase overall after the initiation of Hospital Compare quality scores, but the rate of increase was significantly lower in states with no quality reporting metrics of their own before Hospital Compare, when compared to the control states (annual rates of increase of 4.4 percent versus 8.7 percent for PCI, and 3.9 percent versus 10.6 percent for CABG, adjusted for overall inflation). This finding implies that Hospital Compare provided leverage to purchasers in moderating price increases, while adding competitive pressures on hospitals. Providing accurate quality information on both hospitals and health plans could benefit consumers. Project HOPE—The People-to-People Health Foundation, Inc.

  5. Automated image quality assessment for chest CT scans.

    PubMed

    Reeves, Anthony P; Xie, Yiting; Liu, Shuang

    2018-02-01

    Medical image quality needs to be maintained at standards sufficient for effective clinical reading. Automated computer analytic methods may be applied to medical images for quality assessment. For chest CT scans in a lung cancer screening context, an automated quality assessment method is presented that characterizes image noise and image intensity calibration. This is achieved by image measurements in three automatically segmented homogeneous regions of the scan: external air, trachea lumen air, and descending aorta blood. Profiles of CT scanner behavior are also computed. The method has been evaluated on both phantom and real low-dose chest CT scans and results show that repeatable noise and calibration measures may be realized by automated computer algorithms. Noise and calibration profiles show relevant differences between different scanners and protocols. Automated image quality assessment may be useful for quality control for lung cancer screening and may enable performance improvements to automated computer analysis methods. © 2017 American Association of Physicists in Medicine.

  6. Qualichem In Vivo: A Tool for Assessing the Quality of In Vivo Studies and Its Application for Bisphenol A

    PubMed Central

    Maxim, Laura; van der Sluijs, Jeroen P.

    2014-01-01

    In regulatory toxicology, quality assessment of in vivo studies is a critical step for assessing chemical risks. It is crucial for preserving public health studies that are considered suitable for regulating chemicals are robust. Current procedures for conducting quality assessments in safety agencies are not structured, clear or consistent. This leaves room for criticism about lack of transparency, subjective influence and the potential for insufficient protection provided by resulting safety standards. We propose a tool called “Qualichem in vivo” that is designed to systematically and transparently assess the quality of in vivo studies used in chemical health risk assessment. We demonstrate its use here with 12 experts, using two controversial studies on Bisphenol A (BPA) that played an important role in BPA regulation in Europe. The results obtained with Qualichem contradict the quality assessments conducted by expert committees in safety agencies for both of these studies. Furthermore, they show that reliance on standardized guidelines to ensure scientific quality is only partially justified. Qualichem allows experts with different disciplinary backgrounds and professional experiences to express their individual and sometimes divergent views—an improvement over the current way of dealing with minority opinions. It provides a transparent framework for expressing an aggregated, multi-expert level of confidence in a study, and allows a simple graphical representation of how well the study integrates the best available scientific knowledge. Qualichem can be used to compare assessments of the same study by different health agencies, increasing transparency and trust in the work of expert committees. In addition, it may be used in systematic evaluation of in vivo studies submitted by industry in the dossiers that are required for compliance with the REACH Regulation. Qualichem provides a balanced, common framework for assessing the quality of studies that may

  7. The Papers Printing Quality Complex Assessment Algorithm Development Taking into Account the Composition and Production Technological Features

    NASA Astrophysics Data System (ADS)

    Babakhanova, Kh A.; Varepo, L. G.; Nagornova, I. V.; Babluyk, E. B.; Kondratov, A. P.

    2018-04-01

    Paper is one of the printing system key components causing the high-quality printed products output. Providing the printing companies with the specified printing properties paper, while simultaneously increasing the paper products range and volume by means of the forecasting methods application and evaluation during the production process, is certainly a relevant problem. The paper presents the printing quality control algorithm taking into consideration the paper printing properties quality assessment depending on the manufacture technological features and composition variation. The information system including raw material and paper properties data and making possible pulp and paper enterprises to select paper composition optimal formulation is proposed taking into account the printing process procedure peculiarities of the paper manufacturing with specified printing properties.

  8. Health-related quality-of-life assessment and surgical outcomes for auricular reconstruction using autologous costal cartilage.

    PubMed

    Soukup, Benjamin; Mashhadi, Syed A; Bulstrode, Neil W

    2012-03-01

    This study aims to assess the health-related quality-of-life benefit following auricular reconstruction using autologous costal cartilage in children. In addition, key aspects of the surgical reconstruction are assessed. After auricular reconstruction, patients completed two questionnaires. The first was a postinterventional health-related quality-of-life assessment tool, the Glasgow Benefit Inventory. A score of 0 signifies no change in health-related quality-of-life, +100 indicates maximal improvement, and -100 indicates maximal negative impact. The second questionnaire assessed surgical outcomes in auricular reconstruction across three areas: facial integration, aesthetic auricular units, and costal reconstruction. These were recorded on a five-point ordinal scale and are presented as mean scores of a total of 5. The mean total Glasgow Benefit Inventory score was 48.1; significant improvements were seen in all three Glasgow Benefit Inventory subscales (p < 0.0001). A mean integration score of 3.8 and a mean aesthetic auricular unit reconstruction score of 3.4 were recorded. Skin color matching (4.3) of the ear was most successfully reconstructed and auricular cartilage reconstruction scored lowest (3.5). Of the aesthetic units, the helix scored highest (3.6) and the tragus/antitragus scored lowest (3.3). Donor-site reconstruction scored 3.9. Correlation analysis revealed that higher reconstruction scores are associated with a greater health-related quality-of-life gain (r = 0.5). Ninety-six percent of patients would recommend the procedure to a friend. Auricular reconstruction with autologous cartilage results in significant improvements in health-related quality-of-life. In addition, better surgical outcomes lead to a greater improvement in health-related quality-of-life. Comparatively poorer reconstructed areas of the ear were identified so that surgical techniques may be improved. Therapeutic, IV.

  9. Assessing speech perception in children with cochlear implants using a modified hybrid visual habituation procedure.

    PubMed

    Core, Cynthia; Brown, Janean W; Larsen, Michael D; Mahshie, James

    2014-01-01

    The objectives of this research were to determine whether an adapted version of a Hybrid Visual Habituation procedure could be used to assess speech perception of phonetic and prosodic features of speech (vowel height, lexical stress, and intonation) in individual pre-school-age children who use cochlear implants. Nine children ranging in age from 3;4 to 5;5 participated in this study. Children were prelingually deaf and used cochlear implants and had no other known disabilities. Children received two speech feature tests using an adaptation of a Hybrid Visual Habituation procedure. Seven of the nine children demonstrated perception of at least one speech feature using this procedure using results from a Bayesian linear regression analysis. At least one child demonstrated perception of each speech feature using this assessment procedure. An adapted version of the Hybrid Visual Habituation Procedure with an appropriate statistical analysis provides a way to assess phonetic and prosodicaspects of speech in pre-school-age children who use cochlear implants.

  10. Academics' Perceptions on the Purposes of Quality Assessment

    ERIC Educational Resources Information Center

    Rosa, Maria J.; Sarrico, Claudia S.; Amaral, Alberto

    2012-01-01

    The accountability versus improvement debate is an old one. Although being traditionally considered dichotomous purposes of higher education quality assessment, some authors defend the need of balancing both in quality assessment systems. This article goes a step further and contends that not only they should be balanced but also that other…

  11. Clinical skills assessment of procedural and advanced communication skills: performance expectations of residency program directors.

    PubMed

    Langenau, Erik E; Zhang, Xiuyuan; Roberts, William L; DeChamplain, Andre F; Boulet, John R

    2012-01-01

    High stakes medical licensing programs are planning to augment and adapt current examinations to be relevant for a two-decision point model for licensure: entry into supervised practice and entry into unsupervised practice. Therefore, identifying which skills should be assessed at each decision point is critical for informing examination development, and gathering input from residency program directors is important. Using data from previously developed surveys and expert panels, a web-delivered survey was distributed to 3,443 residency program directors. For each of the 28 procedural and 18 advanced communication skills, program directors were asked which clinical skills should be assessed, by whom, when, and how. Descriptive statistics were collected, and Intraclass Correlations (ICC) were conducted to determine consistency across different specialties. Among 347 respondents, program directors reported that all advanced communication and some procedural tasks are important to assess. The following procedures were considered 'important' or 'extremely important' to assess: sterile technique (93.8%), advanced cardiovascular life support (ACLS) (91.1%), basic life support (BLS) (90.0%), interpretation of electrocardiogram (89.4%) and blood gas (88.7%). Program directors reported that most clinical skills should be assessed at the end of the first year of residency (or later) and not before graduation from medical school. A minority were considered important to assess prior to the start of residency training: demonstration of respectfulness (64%), sterile technique (67.2%), BLS (68.9%), ACLS (65.9%) and phlebotomy (63.5%). Results from this study support that assessing procedural skills such as cardiac resuscitation, sterile technique, and phlebotomy would be amenable to assessment at the end of medical school, but most procedural and advanced communications skills would be amenable to assessment at the end of the first year of residency training or later. Gathering

  12. A framework for assessing Health Economic Evaluation (HEE) quality appraisal instruments.

    PubMed

    Langer, Astrid

    2012-08-16

    Health economic evaluations support the health care decision-making process by providing information on costs and consequences of health interventions. The quality of such studies is assessed by health economic evaluation (HEE) quality appraisal instruments. At present, there is no instrument for measuring and improving the quality of such HEE quality appraisal instruments. Therefore, the objectives of this study are to establish a framework for assessing the quality of HEE quality appraisal instruments to support and improve their quality, and to apply this framework to those HEE quality appraisal instruments which have been subject to more scrutiny than others, in order to test the framework and to demonstrate the shortcomings of existing HEE quality appraisal instruments. To develop the quality assessment framework for HEE quality appraisal instruments, the experiences of using appraisal tools for clinical guidelines are used. Based on a deductive iterative process, clinical guideline appraisal instruments identified through literature search are reviewed, consolidated, and adapted to produce the final quality assessment framework for HEE quality appraisal instruments. The final quality assessment framework for HEE quality appraisal instruments consists of 36 items organized within 7 dimensions, each of which captures a specific domain of quality. Applying the quality assessment framework to four existing HEE quality appraisal instruments, it is found that these four quality appraisal instruments are of variable quality. The framework described in this study should be regarded as a starting point for appraising the quality of HEE quality appraisal instruments. This framework can be used by HEE quality appraisal instrument producers to support and improve the quality and acceptance of existing and future HEE quality appraisal instruments. By applying this framework, users of HEE quality appraisal instruments can become aware of methodological deficiencies

  13. Objective assessment of MPEG-2 video quality

    NASA Astrophysics Data System (ADS)

    Gastaldo, Paolo; Zunino, Rodolfo; Rovetta, Stefano

    2002-07-01

    The increasing use of video compression standards in broadcasting television systems has required, in recent years, the development of video quality measurements that take into account artifacts specifically caused by digital compression techniques. In this paper we present a methodology for the objective quality assessment of MPEG video streams by using circular back-propagation feedforward neural networks. Mapping neural networks can render nonlinear relationships between objective features and subjective judgments, thus avoiding any simplifying assumption on the complexity of the model. The neural network processes an instantaneous set of input values, and yields an associated estimate of perceived quality. Therefore, the neural-network approach turns objective quality assessment into adaptive modeling of subjective perception. The objective features used for the estimate are chosen according to the assessed relevance to perceived quality and are continuously extracted in real time from compressed video streams. The overall system mimics perception but does not require any analytical model of the underlying physical phenomenon. The capability to process compressed video streams represents an important advantage over existing approaches, like avoiding the stream-decoding process greatly enhances real-time performance. Experimental results confirm that the system provides satisfactory, continuous-time approximations for actual scoring curves concerning real test videos.

  14. Air quality procedures for civilian airports and air force bases

    DOT National Transportation Integrated Search

    1997-04-01

    Air Quality assessments for proposed Federal actions are required for compliance with the National Environmental Policy Act, the Clean Air Act and other environment-related regulations and directives. This handbook is a comprehensive guide intended t...

  15. Real-time assessments of water quality: expanding nowcasting throughout the Great Lakes

    USGS Publications Warehouse

    ,

    2013-01-01

    Nowcasts are systems that inform the public of current bacterial water-quality conditions at beaches on the basis of predictive models. During 2010–12, the U.S. Geological Survey (USGS) worked with 23 local and State agencies to improve existing operational beach nowcast systems at 4 beaches and expand the use of predictive models in nowcasts at an additional 45 beaches throughout the Great Lakes. The predictive models were specific to each beach, and the best model for each beach was based on a unique combination of environmental and water-quality explanatory variables. The variables used most often in models to predict Escherichia coli (E. coli) concentrations or the probability of exceeding a State recreational water-quality standard included turbidity, day of the year, wave height, wind direction and speed, antecedent rainfall for various time periods, and change in lake level over 24 hours. During validation of 42 beach models during 2012, the models performed better than the current method to assess recreational water quality (previous day's E. coli concentration). The USGS will continue to work with local agencies to improve nowcast predictions, enable technology transfer of predictive model development procedures, and implement more operational systems during 2013 and beyond.

  16. Relationships Among Traditional and Behavior Assessment Procedures in a Behavioral Research Program.

    ERIC Educational Resources Information Center

    Foster, Carol

    The paper is designed to lay the foundation for a traditional assessment program in a systematic research effort on the identification of and intervention with at risk and handicapped infants and young children. Initial sections review literature on the qualities of traditional psychometric assessment and on the qualities of a behavioral…

  17. Development and Validation of Assessing Quality Teaching Rubrics

    ERIC Educational Resources Information Center

    Chen, Weiyun; Mason, Steve; Hammond-Bennett, Austin; Zlamout, Sandy

    2014-01-01

    Purpose: This study aimed at examining the psychometric properties of the Assessing Quality Teaching Rubric (AQTR) that was designed to assess in-service teachers' quality levels of teaching practices in daily lessons. Methods: 45 physical education lessons taught by nine physical education teachers to students in grades K-5 were videotaped. They…

  18. Evaluation of the indoor air quality minimum ventilation rate procedure for use in California retail buildings.

    PubMed

    Dutton, S M; Mendell, M J; Chan, W R; Barrios, M; Sidheswaran, M A; Sullivan, D P; Eliseeva, E A; Fisk, W J

    2015-02-01

    This research assesses benefits of adding to California Title-24 ventilation rate (VR) standards a performance-based option, similar to the American Society of Heating, Refrigerating, and Air Conditioning Engineers 'Indoor Air Quality Procedure' (IAQP) for retail spaces. Ventilation rates and concentrations of contaminants of concern (CoC) were measured in 13 stores. Mass balance models were used to estimate 'IAQP-based' VRs that would maintain concentrations of all CoCs below health- or odor-based reference concentration limits. An intervention study in a 'big box' store assessed how the current VR, the Title 24-prescribed VR, and the IAQP-based VR (0.24, 0.69, and 1.51 air changes per hour) influenced measured IAQ and perceived of IAQ. Neither current VRs nor Title 24-prescribed VRs would maintain all CoCs below reference limits in 12 of 13 stores. In the big box store, the IAQP-based VR kept all CoCs below limits. More than 80% of subjects reported acceptable air quality at all three VRs. In 11 of 13 buildings, saving energy through lower VRs while maintaining acceptable IAQ would require source reduction or gas-phase air cleaning for CoCs. In only one of the 13 retail stores surveyed, application of the IAQP would have allowed reduced VRs without additional contaminant-reduction strategies. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.

  19. Quality Assessment in the Blog Space

    ERIC Educational Resources Information Center

    Schaal, Markus; Fidan, Guven; Muller, Roland M.; Dagli, Orhan

    2010-01-01

    Purpose: The purpose of this paper is the presentation of a new method for blog quality assessment. The method uses the temporal sequence of link creation events between blogs as an implicit source for the collective tacit knowledge of blog authors about blog quality. Design/methodology/approach: The blog data are processed by the novel method for…

  20. The Assessment Supplement: A Faculty-Designed Addition to NCC's Manual, "Concepts & Procedures for Academic Assessment." First Edition.

    ERIC Educational Resources Information Center

    Nassau Community Coll., Garden City, NY.

    This document is the first in a series of annual, faculty-designed supplements to Nassau Community College's (NCC's) (New York) manual, "Concepts & Procedures for Academic Assessment." The supplements are intended to provide faculty a forum through which they can communicate assessment designs and the impacts of those designs on…

  1. Key Elements for Judging the Quality of a Risk Assessment

    PubMed Central

    Fenner-Crisp, Penelope A.; Dellarco, Vicki L.

    2016-01-01

    Background: Many reports have been published that contain recommendations for improving the quality, transparency, and usefulness of decision making for risk assessments prepared by agencies of the U.S. federal government. A substantial measure of consensus has emerged regarding the characteristics that high-quality assessments should possess. Objective: The goal was to summarize the key characteristics of a high-quality assessment as identified in the consensus-building process and to integrate them into a guide for use by decision makers, risk assessors, peer reviewers and other interested stakeholders to determine if an assessment meets the criteria for high quality. Discussion: Most of the features cited in the guide are applicable to any type of assessment, whether it encompasses one, two, or all four phases of the risk-assessment paradigm; whether it is qualitative or quantitative; and whether it is screening level or highly sophisticated and complex. Other features are tailored to specific elements of an assessment. Just as agencies at all levels of government are responsible for determining the effectiveness of their programs, so too should they determine the effectiveness of their assessments used in support of their regulatory decisions. Furthermore, if a nongovernmental entity wishes to have its assessments considered in the governmental regulatory decision-making process, then these assessments should be judged in the same rigorous manner and be held to similar standards. Conclusions: The key characteristics of a high-quality assessment can be summarized and integrated into a guide for judging whether an assessment possesses the desired features of high quality, transparency, and usefulness. Citation: Fenner-Crisp PA, Dellarco VL. 2016. Key elements for judging the quality of a risk assessment. Environ Health Perspect 124:1127–1135; http://dx.doi.org/10.1289/ehp.1510483 PMID:26862984

  2. Noise Estimation and Quality Assessment of Gaussian Noise Corrupted Images

    NASA Astrophysics Data System (ADS)

    Kamble, V. M.; Bhurchandi, K.

    2018-03-01

    Evaluating the exact quantity of noise present in an image and quality of an image in the absence of reference image is a challenging task. We propose a near perfect noise estimation method and a no reference image quality assessment method for images corrupted by Gaussian noise. The proposed methods obtain initial estimate of noise standard deviation present in an image using the median of wavelet transform coefficients and then obtains a near to exact estimate using curve fitting. The proposed noise estimation method provides the estimate of noise within average error of +/-4%. For quality assessment, this noise estimate is mapped to fit the Differential Mean Opinion Score (DMOS) using a nonlinear function. The proposed methods require minimum training and yields the noise estimate and image quality score. Images from Laboratory for image and Video Processing (LIVE) database and Computational Perception and Image Quality (CSIQ) database are used for validation of the proposed quality assessment method. Experimental results show that the performance of proposed quality assessment method is at par with the existing no reference image quality assessment metric for Gaussian noise corrupted images.

  3. Published methodological quality of randomized controlled trials does not reflect the actual quality assessed in protocols

    PubMed Central

    Mhaskar, Rahul; Djulbegovic, Benjamin; Magazin, Anja; Soares, Heloisa P.; Kumar, Ambuj

    2011-01-01

    Objectives To assess whether reported methodological quality of randomized controlled trials (RCTs) reflect the actual methodological quality, and to evaluate the association of effect size (ES) and sample size with methodological quality. Study design Systematic review Setting Retrospective analysis of all consecutive phase III RCTs published by 8 National Cancer Institute Cooperative Groups until year 2006. Data were extracted from protocols (actual quality) and publications (reported quality) for each study. Results 429 RCTs met the inclusion criteria. Overall reporting of methodological quality was poor and did not reflect the actual high methodological quality of RCTs. The results showed no association between sample size and actual methodological quality of a trial. Poor reporting of allocation concealment and blinding exaggerated the ES by 6% (ratio of hazard ratio [RHR]: 0.94, 95%CI: 0.88, 0.99) and 24% (RHR: 1.24, 95%CI: 1.05, 1.43), respectively. However, actual quality assessment showed no association between ES and methodological quality. Conclusion The largest study to-date shows poor quality of reporting does not reflect the actual high methodological quality. Assessment of the impact of quality on the ES based on reported quality can produce misleading results. PMID:22424985

  4. Procedural Documentation and Accuracy Assessment of Bathymetric Maps and Area/Capacity Tables for Small Reservoirs

    USGS Publications Warehouse

    Wilson, Gary L.; Richards, Joseph M.

    2006-01-01

    Because of the increasing use and importance of lakes for water supply to communities, a repeatable and reliable procedure to determine lake bathymetry and capacity is needed. A method to determine the accuracy of the procedure will help ensure proper collection and use of the data and resulting products. It is important to clearly define the intended products and desired accuracy before conducting the bathymetric survey to ensure proper data collection. A survey-grade echo sounder and differential global positioning system receivers were used to collect water-depth and position data in December 2003 at Sugar Creek Lake near Moberly, Missouri. Data were collected along planned transects, with an additional set of quality-assurance data collected for use in accuracy computations. All collected data were imported into a geographic information system database. A bathymetric surface model, contour map, and area/capacity tables were created from the geographic information system database. An accuracy assessment was completed on the collected data, bathymetric surface model, area/capacity table, and contour map products. Using established vertical accuracy standards, the accuracy of the collected data, bathymetric surface model, and contour map product was 0.67 foot, 0.91 foot, and 1.51 feet at the 95 percent confidence level. By comparing results from different transect intervals with the quality-assurance transect data, it was determined that a transect interval of 1 percent of the longitudinal length of Sugar Creek Lake produced nearly as good results as 0.5 percent transect interval for the bathymetric surface model, area/capacity table, and contour map products.

  5. Assessment of groundwater quality in a typical rural settlement in southwest Nigeria.

    PubMed

    Adekunle, I M; Adetunji, M T; Gbadebo, A M; Banjoko, O P

    2007-12-01

    In most rural settlements in Nigeria, access to clean and potable water is a great challenge, resulting in water borne diseases. The aim of this study was to assess the levels of some physical, chemical, biochemical and microbial water quality parameters in twelve hand - dug wells in a typical rural area (Igbora) of southwest region of the country. Seasonal variations and proximity to pollution sources (municipal waste dumps and defecation sites) were also examined. Parameters were determined using standard procedures. All parameters were detected up to 200 m from pollution source and most of them increased in concentration during the rainy season over the dry periods, pointing to infiltrations from storm water. Coliform population, Pb, NO3- and Cd in most cases, exceeded the World Health Organization recommended thresholds for potable water. Effect of distance from pollution sources was more pronounced on fecal and total coliform counts, which decreased with increasing distance from waste dumps. The qualities of the well water samples were therefore not suitable for human consumption without adequate treatment. Regular monitoring of groundwater quality, abolishment of unhealthy waste disposal practices and introduction of modern techniques are recommended.

  6. A framework for assessing Health Economic Evaluation (HEE) quality appraisal instruments

    PubMed Central

    2012-01-01

    Background Health economic evaluations support the health care decision-making process by providing information on costs and consequences of health interventions. The quality of such studies is assessed by health economic evaluation (HEE) quality appraisal instruments. At present, there is no instrument for measuring and improving the quality of such HEE quality appraisal instruments. Therefore, the objectives of this study are to establish a framework for assessing the quality of HEE quality appraisal instruments to support and improve their quality, and to apply this framework to those HEE quality appraisal instruments which have been subject to more scrutiny than others, in order to test the framework and to demonstrate the shortcomings of existing HEE quality appraisal instruments. Methods To develop the quality assessment framework for HEE quality appraisal instruments, the experiences of using appraisal tools for clinical guidelines are used. Based on a deductive iterative process, clinical guideline appraisal instruments identified through literature search are reviewed, consolidated, and adapted to produce the final quality assessment framework for HEE quality appraisal instruments. Results The final quality assessment framework for HEE quality appraisal instruments consists of 36 items organized within 7 dimensions, each of which captures a specific domain of quality. Applying the quality assessment framework to four existing HEE quality appraisal instruments, it is found that these four quality appraisal instruments are of variable quality. Conclusions The framework described in this study should be regarded as a starting point for appraising the quality of HEE quality appraisal instruments. This framework can be used by HEE quality appraisal instrument producers to support and improve the quality and acceptance of existing and future HEE quality appraisal instruments. By applying this framework, users of HEE quality appraisal instruments can become aware

  7. Automatic first-arrival picking based on extended super-virtual interferometry with quality control procedure

    NASA Astrophysics Data System (ADS)

    An, Shengpei; Hu, Tianyue; Liu, Yimou; Peng, Gengxin; Liang, Xianghao

    2017-12-01

    Static correction is a crucial step of seismic data processing for onshore play, which frequently has a complex near-surface condition. The effectiveness of the static correction depends on an accurate determination of first-arrival traveltimes. However, it is difficult to accurately auto-pick the first arrivals for data with low signal-to-noise ratios (SNR), especially for those measured in the area of the complex near-surface. The technique of the super-virtual interferometry (SVI) has the potential to enhance the SNR of first arrivals. In this paper, we develop the extended SVI with (1) the application of the reverse correlation to improve the capability of SNR enhancement at near-offset, and (2) the usage of the multi-domain method to partially overcome the limitation of current method, given insufficient available source-receiver combinations. Compared to the standard SVI, the SNR enhancement of the extended SVI can be up to 40%. In addition, we propose a quality control procedure, which is based on the statistical characteristics of multichannel recordings of first arrivals. It can auto-correct the mispicks, which might be spurious events generated by the SVI. This procedure is very robust, highly automatic and it can accommodate large data in batches. Finally, we develop one automatic first-arrival picking method to combine the extended SVI and the quality control procedure. Both the synthetic and the field data examples demonstrate that the proposed method is able to accurately auto-pick first arrivals in seismic traces with low SNR. The quality of the stacked seismic sections obtained from this method is much better than those obtained from an auto-picking method, which is commonly employed by the commercial software.

  8. Neurophysiological changes associated with implant-associated augmentation procedures in the lower jaw.

    PubMed

    Hartmann, Amely; Welte-Jzyk, Claudia; Seiler, Marcus; Daubländer, Monika

    2017-08-01

    Neurophysiological changes after oral and maxillofacial surgery remain one of the topics of current research. This study evaluated if implant placement associated with augmentation procedures increases the possibility of sensory disturbances or result in impaired quality of life during the healing period. Patients who had obtained an implant placement in the lower jaw in combination with augmentation procedures were examined by implementing a comprehensive Quantitative Sensory Testing (QST) protocol for extra- and intraoral use. As augmentation procedures, we used Guided Bone Regeneration (Group A) and Customized Bone Regeneration (Group B) techniques. Patients were tested bilaterally at the chin and mucosal lower lip. Results were compared to a group without augmentation procedures (Group C). Patients' quality of life and psychological comorbidity after the surgical procedures was assessed with the Oral Health Impact Profile and the Hospital Anxiety and Depression Scale. For groups A (n = 20) and B (n = 8), mechanical QST parameters showed no significant differences in all qualities of the inferior alveolar nerve compared to the contralateral side and compared to the nonaugmentation control group (n = 32) as well. Evaluation of quality of life and psychological factors showed no statistical differences. Augmentation procedures did not increase sensory disturbances, indicating no changes in the neurophysiological pathways. Extended augmentation procedures did not lead to sensory changes either or result in an impaired quality of life or modified anxiety and depression scores. © 2017 Wiley Periodicals, Inc.

  9. [What is the methodological quality of articles on therapeutic procedures published in Cirugía Española?].

    PubMed

    Manterola, Carlos; Busquets, Juli; Pascual, Marta; Grande, Luis

    2006-02-01

    The aim of this study was to determine the methodological quality of articles on therapeutic procedures published in Cirugía Española and to study its association with the publication year, center, and subject-matter. A bibliometric study that included all articles on therapeutic procedures published in Cirugía Española between 2001 and 2004 was performed. All kinds of clinical designs were considered, excluding editorials, review articles, letters to editor, and experimental studies. The variables analyzed were: year of publication, center, design, and methodological quality. Methodological quality was determined by a valid and reliable scale. Descriptive statistics (calculation of means, standard deviation and medians) and analytical statistics (Pearson's chi2, nonparametric, ANOVA and Bonferroni tests) were used. A total of 244 articles were studied (197 case series [81%], 28 cohort studies [12%], 17 clinical trials [7%], 1 cross sectional study and 1 case-control study [0.8%]). The studies were performed mainly in Catalonia and Murcia (22% and 16%, respectively). The most frequent subject areas were soft tissue and hepatobiliopancreatic surgery (23% and 19%, respectively). The mean and median of the methodological quality score calculated for the entire series was 10.2 +/- 3.9 points and 9.5 points, respectively. Methodological quality significantly increased by publication year (p < 0.001). An association between methodological quality and subject area was observed but no association was detected with the center performing the study. The methodological quality of articles on therapeutic procedures published in Cirugía Española between 2001 and 2004 is low. However, a statistically significant trend toward improvement was observed.

  10. International drug price comparisons: quality assessment.

    PubMed

    Machado, Márcio; O'Brodovich, Ryan; Krahn, Murray; Einarson, Thomas R

    2011-01-01

    To quantitatively summarize results (i.e., prices and affordability) reported from international drug price comparison studies and assess their methodological quality. A systematic search of the most relevant databases-Medline, Embase, International Pharmaceutical Abstracts (IPA), and Scopus, from their inception to May 2009-was conducted to identify original research comparing international drug prices. International drug price information was extracted and recorded from accepted papers. Affordability was reported as drug prices adjusted for income. Study quality was assessed using six criteria: use of similar countries, use of a representative sample of drugs, selection of specific types of prices, identification of drug packaging, different weights on price indices, and the type of currency conversion used. Of the 1 828 studies identified, 21 were included. Only one study adequately addressed all quality issues. A large variation in study quality was observed due to the many methods used to conduct the drug price comparisons, such as different indices, economic parameters, price types, basket of drugs, and more. Thus, the quality of published studies was considered poor. Results varied across studies, but generally, higher income countries had higher drug prices. However, after adjusting drug prices for affordability, higher income countries had more affordable prices than lower income countries. Differences between drug prices and affordability in different countries were found. Low income countries reported less affordability of drugs, leaving room for potential problems with drug access, and consequently, a negative impact on health. The quality of the literature on this topic needs improvement.

  11. E-Services quality assessment framework for collaborative networks

    NASA Astrophysics Data System (ADS)

    Stegaru, Georgiana; Danila, Cristian; Sacala, Ioan Stefan; Moisescu, Mihnea; Mihai Stanescu, Aurelian

    2015-08-01

    In a globalised networked economy, collaborative networks (CNs) are formed to take advantage of new business opportunities. Collaboration involves shared resources and capabilities, such as e-Services that can be dynamically composed to automate CN participants' business processes. Quality is essential for the success of business process automation. Current approaches mostly focus on quality of service (QoS)-based service selection and ranking algorithms, overlooking the process of service composition which requires interoperable, adaptable and secure e-Services to ensure seamless collaboration, data confidentiality and integrity. Lack of assessment of these quality attributes can result in e-Service composition failure. The quality of e-Service composition relies on the quality of each e-Service and on the quality of the composition process. Therefore, there is the need for a framework that addresses quality from both views: product and process. We propose a quality of e-Service composition (QoESC) framework for quality assessment of e-Service composition for CNs which comprises of a quality model for e-Service evaluation and guidelines for quality of e-Service composition process. We implemented a prototype considering a simplified telemedicine use case which involves a CN in e-Healthcare domain. To validate the proposed quality-driven framework, we analysed service composition reliability with and without using the proposed framework.

  12. Assessing primary care data quality.

    PubMed

    Lim, Yvonne Mei Fong; Yusof, Maryati; Sivasampu, Sheamini

    2018-04-16

    Purpose The purpose of this paper is to assess National Medical Care Survey data quality. Design/methodology/approach Data completeness and representativeness were computed for all observations while other data quality measures were assessed using a 10 per cent sample from the National Medical Care Survey database; i.e., 12,569 primary care records from 189 public and private practices were included in the analysis. Findings Data field completion ranged from 69 to 100 per cent. Error rates for data transfer from paper to web-based application varied between 0.5 and 6.1 per cent. Error rates arising from diagnosis and clinical process coding were higher than medication coding. Data fields that involved free text entry were more prone to errors than those involving selection from menus. The authors found that completeness, accuracy, coding reliability and representativeness were generally good, while data timeliness needs to be improved. Research limitations/implications Only data entered into a web-based application were examined. Data omissions and errors in the original questionnaires were not covered. Practical implications Results from this study provided informative and practicable approaches to improve primary health care data completeness and accuracy especially in developing nations where resources are limited. Originality/value Primary care data quality studies in developing nations are limited. Understanding errors and missing data enables researchers and health service administrators to prevent quality-related problems in primary care data.

  13. Assessing the quality of cost management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fayne, V.; McAllister, A.; Weiner, S.B.

    1995-12-31

    Managing environmental programs can be effective only when good cost and cost-related management practices are developed and implemented. The Department of Energy`s Office of Environmental Management (EM), recognizing this key role of cost management, initiated several cost and cost-related management activities including the Cost Quality Management (CQM) Program. The CQM Program includes an assessment activity, Cost Quality Management Assessments (CQMAs), and a technical assistance effort to improve program/project cost effectiveness. CQMAs provide a tool for establishing a baseline of cost-management practices and for measuring improvement in those practices. The result of the CQMA program is an organization that has anmore » increasing cost-consciousness, improved cost-management skills and abilities, and a commitment to respond to the public`s concerns for both a safe environment and prudent budget outlays. The CQMA program is part of the foundation of quality management practices in DOE. The CQMA process has contributed to better cost and cost-related management practices by providing measurements and feedback; defining the components of a quality cost-management system; and helping sites develop/improve specific cost-management techniques and methods.« less

  14. Quality assurance procedures for environmental control and monitoring in plant growth facilities. Report of the North Central Regional 101 Committee on Growth Chamber Use

    NASA Technical Reports Server (NTRS)

    Tibbitts, T. W. (Principal Investigator)

    1986-01-01

    This report includes procedures for ensuring the quality of the environment provided for plant growth in controlled environment facilities. Biologists and engineers may use these procedures for ensuring quality control during experiments or for ensuring quality control in the design of plant growth facilities. Environmental monitoring prior to and during experiments is included in these procedures. Specific recommendations cover control, acquisition, and calibration for sensor types for the separate parameters of radiation (light), temperature, humidity, carbon dioxide, and air movement.

  15. A new method for water quality assessment: by harmony degree equation.

    PubMed

    Zuo, Qiting; Han, Chunhui; Liu, Jing; Ma, Junxia

    2018-02-22

    Water quality assessment is an important basic work in the development, utilization, management, and protection of water resources, and also a prerequisite for water safety. In this paper, the harmony degree equation (HDE) was introduced into the research of water quality assessment, and a new method for water quality assessment was proposed according to the HDE: by harmony degree equation (WQA-HDE). First of all, the calculation steps and ideas of this method were described in detail, and then, this method with some other important methods of water quality assessment (single factor assessment method, mean-type comprehensive index assessment method, and multi-level gray correlation assessment method) were used to assess the water quality of the Shaying River (the largest tributary of the Huaihe in China). For this purpose, 2 years (2013-2014) dataset of nine water quality variables covering seven monitoring sites, and approximately 189 observations were used to compare and analyze the characteristics and advantages of the new method. The results showed that the calculation steps of WQA-HDE are similar to the comprehensive assessment method, and WQA-HDE is more operational comparing with the results of other water quality assessment methods. In addition, this new method shows good flexibility by setting the judgment criteria value HD 0 of water quality; when HD 0  = 0.8, the results are closer to reality, and more realistic and reliable. Particularly, when HD 0  = 1, the results of WQA-HDE are consistent with the single factor assessment method, both methods are subject to the most stringent "one vote veto" judgment condition. So, WQA-HDE is a composite method that combines the single factor assessment and comprehensive assessment. This research not only broadens the research field of theoretical method system of harmony theory but also promotes the unity of water quality assessment method and can be used for reference in other comprehensive assessment.

  16. Published methodological quality of randomized controlled trials does not reflect the actual quality assessed in protocols.

    PubMed

    Mhaskar, Rahul; Djulbegovic, Benjamin; Magazin, Anja; Soares, Heloisa P; Kumar, Ambuj

    2012-06-01

    To assess whether the reported methodological quality of randomized controlled trials (RCTs) reflects the actual methodological quality and to evaluate the association of effect size (ES) and sample size with methodological quality. Systematic review. This is a retrospective analysis of all consecutive phase III RCTs published by eight National Cancer Institute Cooperative Groups up to 2006. Data were extracted from protocols (actual quality) and publications (reported quality) for each study. Four hundred twenty-nine RCTs met the inclusion criteria. Overall reporting of methodological quality was poor and did not reflect the actual high methodological quality of RCTs. The results showed no association between sample size and actual methodological quality of a trial. Poor reporting of allocation concealment and blinding exaggerated the ES by 6% (ratio of hazard ratio [RHR]: 0.94; 95% confidence interval [CI]: 0.88, 0.99) and 24% (RHR: 1.24; 95% CI: 1.05, 1.43), respectively. However, actual quality assessment showed no association between ES and methodological quality. The largest study to date shows that poor quality of reporting does not reflect the actual high methodological quality. Assessment of the impact of quality on the ES based on reported quality can produce misleading results. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. 42 CFR 460.136 - Internal quality assessment and performance improvement activities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Internal quality assessment and performance improvement activities. 460.136 Section 460.136 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES....136 Internal quality assessment and performance improvement activities. (a) Quality assessment and...

  18. 42 CFR 460.136 - Internal quality assessment and performance improvement activities.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... in quality assessment and performance improvement activities, including providing information about... 42 Public Health 4 2014-10-01 2014-10-01 false Internal quality assessment and performance...) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Quality Assessment and Performance Improvement § 460...

  19. 42 CFR 460.136 - Internal quality assessment and performance improvement activities.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... in quality assessment and performance improvement activities, including providing information about... 42 Public Health 4 2012-10-01 2012-10-01 false Internal quality assessment and performance...) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Quality Assessment and Performance Improvement § 460...

  20. 42 CFR 460.136 - Internal quality assessment and performance improvement activities.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... in quality assessment and performance improvement activities, including providing information about... 42 Public Health 4 2013-10-01 2013-10-01 false Internal quality assessment and performance...) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Quality Assessment and Performance Improvement § 460...

  1. Illinois Quality Counts: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Illinois' Quality Counts prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for Family…

  2. [Risk management--a new aspect of quality assessment in intensive care medicine: first results of an analysis of the DIVI's interdisciplinary quality assessment research group].

    PubMed

    Stiletto, R; Röthke, M; Schäfer, E; Lefering, R; Waydhas, Ch

    2006-10-01

    Patient security has become one of the major aspects of clinical management in recent years. The crucial point in research was focused on malpractice. In contradiction to the economic process in non medical fields, the analysis of errors during the in-patient treatment time was neglected. Patient risk management can be defined as a structured procedure in a clinical unit with the aim to reduce harmful events. A risk point model was created based on a Delphi process and founded on the DIVI data register. The risk point model was evaluated in clinically working ICU departments participating in the register data base. The results of the risk point evaluation will be integrated in the next data base update. This might be a step to improve the reliability of the register to measure quality assessment in the ICU.

  3. A new approach to subjectively assess quality of plenoptic content

    NASA Astrophysics Data System (ADS)

    Viola, Irene; Řeřábek, Martin; Ebrahimi, Touradj

    2016-09-01

    Plenoptic content is becoming increasingly popular thanks to the availability of acquisition and display devices. Thanks to image-based rendering techniques, a plenoptic content can be rendered in real time in an interactive manner allowing virtual navigation through the captured scenes. This way of content consumption enables new experiences, and therefore introduces several challenges in terms of plenoptic data processing, transmission and consequently visual quality evaluation. In this paper, we propose a new methodology to subjectively assess the visual quality of plenoptic content. We also introduce a prototype software to perform subjective quality assessment according to the proposed methodology. The proposed methodology is further applied to assess the visual quality of a light field compression algorithm. Results show that this methodology can be successfully used to assess the visual quality of plenoptic content.

  4. Clinical skills assessment of procedural and advanced communication skills: performance expectations of residency program directors

    PubMed Central

    Langenau, Erik E.; Zhang, Xiuyuan; Roberts, William L.; DeChamplain, Andre F.; Boulet, John R.

    2012-01-01

    Background High stakes medical licensing programs are planning to augment and adapt current examinations to be relevant for a two-decision point model for licensure: entry into supervised practice and entry into unsupervised practice. Therefore, identifying which skills should be assessed at each decision point is critical for informing examination development, and gathering input from residency program directors is important. Methods Using data from previously developed surveys and expert panels, a web-delivered survey was distributed to 3,443 residency program directors. For each of the 28 procedural and 18 advanced communication skills, program directors were asked which clinical skills should be assessed, by whom, when, and how. Descriptive statistics were collected, and Intraclass Correlations (ICC) were conducted to determine consistency across different specialties. Results Among 347 respondents, program directors reported that all advanced communication and some procedural tasks are important to assess. The following procedures were considered ‘important’ or ‘extremely important’ to assess: sterile technique (93.8%), advanced cardiovascular life support (ACLS) (91.1%), basic life support (BLS) (90.0%), interpretation of electrocardiogram (89.4%) and blood gas (88.7%). Program directors reported that most clinical skills should be assessed at the end of the first year of residency (or later) and not before graduation from medical school. A minority were considered important to assess prior to the start of residency training: demonstration of respectfulness (64%), sterile technique (67.2%), BLS (68.9%), ACLS (65.9%) and phlebotomy (63.5%). Discussion Results from this study support that assessing procedural skills such as cardiac resuscitation, sterile technique, and phlebotomy would be amenable to assessment at the end of medical school, but most procedural and advanced communications skills would be amenable to assessment at the end of the first

  5. 42 CFR 493.1239 - Standard: General laboratory systems quality assessment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... of general laboratory systems quality assessment reviews with appropriate staff. (c) The laboratory must document all general laboratory systems quality assessment activities. [68 FR 3703, Jan. 24, 2003... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: General laboratory systems quality...

  6. Quality control in public participation assessments of water quality: the OPAL Water Survey.

    PubMed

    Rose, N L; Turner, S D; Goldsmith, B; Gosling, L; Davidson, T A

    2016-07-22

    Public participation in scientific data collection is a rapidly expanding field. In water quality surveys, the involvement of the public, usually as trained volunteers, generally includes the identification of aquatic invertebrates to a broad taxonomic level. However, quality assurance is often not addressed and remains a key concern for the acceptance of publicly-generated water quality data. The Open Air Laboratories (OPAL) Water Survey, launched in May 2010, aimed to encourage interest and participation in water science by developing a 'low-barrier-to-entry' water quality survey. During 2010, over 3000 participant-selected lakes and ponds were surveyed making this the largest public participation lake and pond survey undertaken to date in the UK. But the OPAL approach of using untrained volunteers and largely anonymous data submission exacerbates quality control concerns. A number of approaches were used in order to address data quality issues including: sensitivity analysis to determine differences due to operator, sampling effort and duration; direct comparisons of identification between participants and experienced scientists; the use of a self-assessment identification quiz; the use of multiple participant surveys to assess data variability at single sites over short periods of time; comparison of survey techniques with other measurement variables and with other metrics generally considered more accurate. These quality control approaches were then used to screen the OPAL Water Survey data to generate a more robust dataset. The OPAL Water Survey results provide a regional and national assessment of water quality as well as a first national picture of water clarity (as suspended solids concentrations). Less than 10 % of lakes and ponds surveyed were 'poor' quality while 26.8 % were in the highest water quality band. It is likely that there will always be a question mark over untrained volunteer generated data simply because quality assurance is uncertain

  7. Assessment Quality and Practices in Secondary PE in the Netherlands

    ERIC Educational Resources Information Center

    Borghouts, Lars B.; Slingerland, Menno; Haerens, Leen

    2017-01-01

    Background: Assessment can have various functions, and is an important impetus for student learning. For assessment to be effective, it should be aligned with curriculum goals and of sufficient quality. Although it has been suggested that assessment quality in physical education (PE) is suboptimal, research into actual assessment practices has…

  8. Selecting Statistical Procedures for Quality Control Planning Based on Risk Management.

    PubMed

    Yago, Martín; Alcover, Silvia

    2016-07-01

    According to the traditional approach to statistical QC planning, the performance of QC procedures is assessed in terms of its probability of rejecting an analytical run that contains critical size errors (PEDC). Recently, the maximum expected increase in the number of unacceptable patient results reported during the presence of an undetected out-of-control error condition [Max E(NUF)], has been proposed as an alternative QC performance measure because it is more related to the current introduction of risk management concepts for QC planning in the clinical laboratory. We used a statistical model to investigate the relationship between PEDC and Max E(NUF) for simple QC procedures widely used in clinical laboratories and to construct charts relating Max E(NUF) with the capability of the analytical process that allow for QC planning based on the risk of harm to a patient due to the report of erroneous results. A QC procedure shows nearly the same Max E(NUF) value when used for controlling analytical processes with the same capability, and there is a close relationship between PEDC and Max E(NUF) for simple QC procedures; therefore, the value of PEDC can be estimated from the value of Max E(NUF) and vice versa. QC procedures selected by their high PEDC value are also characterized by a low value for Max E(NUF). The PEDC value can be used for estimating the probability of patient harm, allowing for the selection of appropriate QC procedures in QC planning based on risk management. © 2016 American Association for Clinical Chemistry.

  9. Brief surgical procedure code lists for outcomes measurement and quality improvement in resource-limited settings.

    PubMed

    Liu, Charles; Kayima, Peter; Riesel, Johanna; Situma, Martin; Chang, David; Firth, Paul

    2017-11-01

    The lack of a classification system for surgical procedures in resource-limited settings hinders outcomes measurement and reporting. Existing procedure coding systems are prohibitively large and expensive to implement. We describe the creation and prospective validation of 3 brief procedure code lists applicable in low-resource settings, based on analysis of surgical procedures performed at Mbarara Regional Referral Hospital, Uganda's second largest public hospital. We reviewed operating room logbooks to identify all surgical operations performed at Mbarara Regional Referral Hospital during 2014. Based on the documented indication for surgery and procedure(s) performed, we assigned each operation up to 4 procedure codes from the International Classification of Diseases, 9th Revision, Clinical Modification. Coding of procedures was performed by 2 investigators, and a random 20% of procedures were coded by both investigators. These codes were aggregated to generate procedure code lists. During 2014, 6,464 surgical procedures were performed at Mbarara Regional Referral Hospital, to which we assigned 435 unique procedure codes. Substantial inter-rater reliability was achieved (κ = 0.7037). The 111 most common procedure codes accounted for 90% of all codes assigned, 180 accounted for 95%, and 278 accounted for 98%. We considered these sets of codes as 3 procedure code lists. In a prospective validation, we found that these lists described 83.2%, 89.2%, and 92.6% of surgical procedures performed at Mbarara Regional Referral Hospital during August to September of 2015, respectively. Empirically generated brief procedure code lists based on International Classification of Diseases, 9th Revision, Clinical Modification can be used to classify almost all surgical procedures performed at a Ugandan referral hospital. Such a standardized procedure coding system may enable better surgical data collection for administration, research, and quality improvement in resource

  10. Morphology, geology and water quality assessment of former tin mining catchment.

    PubMed

    Ashraf, Muhammad Aqeel; Maah, Mohd Jamil; Yusoff, Ismail

    2012-01-01

    Bestari Jaya, former tin mining catchment covers an area of 2656.31 hectares comprised of four hundred and forty-two different-size lakes and ponds. The present study area comprise of 92 hectares of the catchment that include four large size lakes. Arc GIS version 9.2 used to develop bathymetric map, Global Positioning System (GPS) for hydrographical survey and flow meter was utilized for water discharge analysis (flow routing) of the catchment. The water quality parameters (pH, temperature, electric conductivity, dissolved oxygen DO, total dissolved solids TDS, chlorides, ammonium, nitrates) were analyzed by using Hydrolab. Quality assurance (QA) and quality control (QC) procedures were strictly followed throughout the field work and data analysis. Different procedures were employed to evaluate the analytical data and to check for possible transcription or dilution errors, changes during analysis, or unusual or unlikely values. The results obtained are compared with interim national water quality standards for Malaysia indicates that water quality of area is highly degraded. It is concluded that Bestri Jaya ex-mining catchment has a high pollution potential due to mining activities and River Ayer Hitam, recipient of catchment water, is a highly polluted river.

  11. Morphology, Geology and Water Quality Assessment of Former Tin Mining Catchment

    PubMed Central

    Ashraf, Muhammad Aqeel; Maah, Mohd. Jamil; Yusoff, Ismail

    2012-01-01

    Bestari Jaya, former tin mining catchment covers an area of 2656.31 hectares comprised of four hundred and forty-two different-size lakes and ponds. The present study area comprise of 92 hectares of the catchment that include four large size lakes. Arc GIS version 9.2 used to develop bathymetric map, Global Positioning System (GPS) for hydrographical survey and flow meter was utilized for water discharge analysis (flow routing) of the catchment. The water quality parameters (pH, temperature, electric conductivity, dissolved oxygen DO, total dissolved solids TDS, chlorides, ammonium, nitrates) were analyzed by using Hydrolab. Quality assurance (QA) and quality control (QC) procedures were strictly followed throughout the field work and data analysis. Different procedures were employed to evaluate the analytical data and to check for possible transcription or dilution errors, changes during analysis, or unusual or unlikely values. The results obtained are compared with interim national water quality standards for Malaysia indicates that water quality of area is highly degraded. It is concluded that Bestri Jaya ex-mining catchment has a high pollution potential due to mining activities and River Ayer Hitam, recipient of catchment water, is a highly polluted river. PMID:22761549

  12. How to conduct External Quality Assessment Schemes for the pre-analytical phase?

    PubMed

    Kristensen, Gunn B B; Aakre, Kristin Moberg; Kristoffersen, Ann Helen; Sandberg, Sverre

    2014-01-01

    In laboratory medicine, several studies have described the most frequent errors in the different phases of the total testing process, and a large proportion of these errors occur in the pre-analytical phase. Schemes for registration of errors and subsequent feedback to the participants have been conducted for decades concerning the analytical phase by External Quality Assessment (EQA) organizations operating in most countries. The aim of the paper is to present an overview of different types of EQA schemes for the pre-analytical phase, and give examples of some existing schemes. So far, very few EQA organizations have focused on the pre-analytical phase, and most EQA organizations do not offer pre-analytical EQA schemes (EQAS). It is more difficult to perform and standardize pre-analytical EQAS and also, accreditation bodies do not ask the laboratories for results from such schemes. However, some ongoing EQA programs for the pre-analytical phase do exist, and some examples are given in this paper. The methods used can be divided into three different types; collecting information about pre-analytical laboratory procedures, circulating real samples to collect information about interferences that might affect the measurement procedure, or register actual laboratory errors and relate these to quality indicators. These three types have different focus and different challenges regarding implementation, and a combination of the three is probably necessary to be able to detect and monitor the wide range of errors occurring in the pre-analytical phase.

  13. Quality assessment concept of the World Data Center for Climate and its application to CMIP5 data

    NASA Astrophysics Data System (ADS)

    Stockhause, M.; Höck, H.; Toussaint, F.; Lautenschlager, M.

    2012-08-01

    The preservation of data in a high state of quality which is suitable for interdisciplinary use is one of the most pressing and challenging current issues in long-term archiving. For high volume data such as climate model data, the data and data replica are no longer stored centrally but distributed over several local data repositories, e.g. the data of the Climate Model Intercomparison Project Phase 5 (CMIP5). The most important part of the data is to be archived, assigned a DOI, and published according to the World Data Center for Climate's (WDCC) application of the DataCite regulations. The integrated part of WDCC's data publication process, the data quality assessment, was adapted to the requirements of a federated data infrastructure. A concept of a distributed and federated quality assessment procedure was developed, in which the workload and responsibility for quality control is shared between the three primary CMIP5 data centers: Program for Climate Model Diagnosis and Intercomparison (PCMDI), British Atmospheric Data Centre (BADC), and WDCC. This distributed quality control concept, its pilot implementation for CMIP5, and first experiences are presented. The distributed quality control approach is capable of identifying data inconsistencies and to make quality results immediately available for data creators, data users and data infrastructure managers. Continuous publication of new data versions and slow data replication prevents the quality control from check completion. This together with ongoing developments of the data and metadata infrastructure requires adaptations in code and concept of the distributed quality control approach.

  14. Southwest principal aquifers regional ground-water quality assessment

    USGS Publications Warehouse

    Anning, D.W.; Thiros, Susan A.; Bexfield, L.M.; McKinney, T.S.; Green, J.M.

    2009-01-01

    The National Water-Quality Assessment (NAWQA) Program of the U.S. Geological Survey is conducting a regional analysis of water quality in the principal aquifers in the southwestern United States. The Southwest Principal Aquifers (SWPA) study is building a better understanding of the susceptibility and vulnerability of basin-fill aquifers in the region to ground-water contamination by synthesizing the baseline knowledge of ground-water quality conditions in 15 basins previously studied by the NAWQA Program. The improved understanding of aquifer susceptibility and vulnerability to contamination is assisting in the development of tools that water managers can use to assess and protect the quality of ground-water resources. This fact sheet provides an overview of the basin-fill aquifers in the southwestern United States and description of the completed and planned regional analyses of ground-water quality being performed by the SWPA study.

  15. A research review of quality assessment for software

    NASA Technical Reports Server (NTRS)

    1991-01-01

    Measures were recommended to assess the quality of software submitted to the AdaNet program. The quality factors that are important to software reuse are explored and methods of evaluating those factors are discussed. Quality factors important to software reuse are: correctness, reliability, verifiability, understandability, modifiability, and certifiability. Certifiability is included because the documentation of many factors about a software component such as its efficiency, portability, and development history, constitute a class for factors important to some users, not important at all to other, and impossible for AdaNet to distinguish between a priori. The quality factors may be assessed in different ways. There are a few quantitative measures which have been shown to indicate software quality. However, it is believed that there exists many factors that indicate quality and have not been empirically validated due to their subjective nature. These subjective factors are characterized by the way in which they support the software engineering principles of abstraction, information hiding, modularity, localization, confirmability, uniformity, and completeness.

  16. Sediment quality assessment in a coastal lagoon (Ravenna, NE Italy) based on SEM-AVS and sequential extraction procedure.

    PubMed

    Pignotti, Emanuela; Guerra, Roberta; Covelli, Stefano; Fabbri, Elena; Dinelli, Enrico

    2018-09-01

    Sediments from the Pialassa Piomboni coastal lagoon (NE Italy) were studied to assess the degree of contamination and ecological risk related to trace metals by combining a geochemical characterization of bulk sediments with the assessment of the bioavailable forms of trace metals. With this purpose, sediment contamination (Cd, Cu, Hg, Ni, Pb, and Zn) was assessed by Enrichment Factors (EFs), and potential bioavailability by the Simultaneously Extracted Metals and Acid Volatile Sulfides (SEM-AVS) approach (Cd, Cu, Ni, Pb, and Zn), and by Sequential Extraction Procedure (Co, Cr, Cu, Ni, Pb, and Zn). On average, Cr and Ni exhibited no contamination (EF ≤1.5), and a predominance in the residual fraction of the sediment, indicating natural origin for these metals. Cu, Pb and Zn displayed a local contamination, which resulted in a higher proportion of Cu bound to the reducible and oxidizable fractions (~30% and ~40% as median, respectively), and Pb mostly associated with the reducible phase (~60% as median). Hence, Cu and Pb could be mobilized when environmental conditions become reducing or oxidizing. Zn resulted mainly partitioned into the reducible and residual fractions (~50% as median, in both fractions). The Risk Assessment Code (RAC) indicated that approximately 30% of samples had >10% of total Zn weakly bound to the sediment, suggesting a medium risk of exposure for aquatic organisms. RAC results were consistent with the ∑SEM-AVS findings, pointing to possible adverse effects for aquatic biota in ~30% of samples, with Zn mostly accounting for the total metal bioavailability. Hg showed a moderate to very severe enrichment, indicating that a substantial amount of this metal derives from anthropogenic sources and may pose adverse effects on the aquatic biota of the Pialassa Piomboni lagoon. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Quality assessments for cancer centers in the European Union.

    PubMed

    Wind, Anke; Rajan, Abinaya; van Harten, Wim H

    2016-09-07

    Cancer centers are pressured to deliver high-quality services that can be measured and improved, which has led to an increase of assessments in many countries. A critical area of quality improvement is to improve patient outcome. An overview of existing assessments can help stakeholders (e.g., healthcare professionals, managers and policy makers) improve the quality of cancer research and care and lead to patient benefits. This paper presents key aspects of assessments undertaken by European cancer centers, such as: are assessments mandatory or voluntary? Do they focus on evaluating research, care or both? And are they international or national? A survey was sent to 33 cancer centers in 28 European Union member states. Participants were asked to score the specifics for each assessment that they listed. Based on the responses from 19 cancer centers from 18 member states, we found 109 assessments. The numbers have steadily increased from 1990's till 2015. Although, a majority of assessments are on patient-care aspects (n = 45), it is unclear how many of those include assessing patient benefits. Only few assessments cover basic research. There is an increasing trend towards mixed assessments (i.e., combining research and patient-care aspects) The need for assessments in cancer centers is increasing. To improve efforts in the quality of research and patient care and to prevent new assessments that "reinvent the wheel", it is advised to start comparative research into the assessments that are likely to bring patient benefits and improve patient outcome. Do assessments provide consistent and reliable information that create added value for all key stakeholders?

  18. Perioperative outcomes for pediatric neurosurgical procedures: analysis of the National Surgical Quality Improvement Program-Pediatrics.

    PubMed

    Kuo, Benjamin J; Vissoci, Joao Ricardo N; Egger, Joseph R; Smith, Emily R; Grant, Gerald A; Haglund, Michael M; Rice, Henry E

    2017-03-01

    OBJECTIVE Existing studies have shown a high overall rate of adverse events (AEs) following pediatric neurosurgical procedures. However, little is known regarding the morbidity of specific procedures or the association with risk factors to help guide quality improvement (QI) initiatives. The goal of this study was to describe the 30-day mortality and AE rates for pediatric neurosurgical procedures by using the American College of Surgeons (ACS) National Surgical Quality Improvement Program-Pediatrics (NSQIP-Peds) database platform. METHODS Data on 9996 pediatric neurosurgical patients were acquired from the 2012-2014 NSQIP-Peds participant user file. Neurosurgical cases were analyzed by the NSQIP-Peds targeted procedure categories, including craniotomy/craniectomy, defect repair, laminectomy, shunts, and implants. The primary outcome measure was 30-day mortality, with secondary outcomes including individual AEs, composite morbidity (all AEs excluding mortality and unplanned reoperation), surgical-site infection, and unplanned reoperation. Univariate analysis was performed between individual AEs and patient characteristics using Fischer's exact test. Associations between individual AEs and continuous variables (duration from admission to operation, work relative value unit, and operation time) were examined using the Student t-test. Patient characteristics and continuous variables associated with any AE by univariate analysis were used to develop category-specific multivariable models through backward stepwise logistic regression. RESULTS The authors analyzed 3383 craniotomy/craniectomy, 242 defect repair, 1811 laminectomy, and 4560 shunt and implant cases and found a composite overall morbidity of 30.2%, 38.8%, 10.2%, and 10.7%, respectively. Unplanned reoperation rates were highest for defect repair (29.8%). The mortality rate ranged from 0.1% to 1.2%. Preoperative ventilator dependence was a significant predictor of any AE for all procedure groups, whereas

  19. A systematic literature review of open source software quality assessment models.

    PubMed

    Adewumi, Adewole; Misra, Sanjay; Omoregbe, Nicholas; Crawford, Broderick; Soto, Ricardo

    2016-01-01

    Many open source software (OSS) quality assessment models are proposed and available in the literature. However, there is little or no adoption of these models in practice. In order to guide the formulation of newer models so they can be acceptable by practitioners, there is need for clear discrimination of the existing models based on their specific properties. Based on this, the aim of this study is to perform a systematic literature review to investigate the properties of the existing OSS quality assessment models by classifying them with respect to their quality characteristics, the methodology they use for assessment, and their domain of application so as to guide the formulation and development of newer models. Searches in IEEE Xplore, ACM, Science Direct, Springer and Google Search is performed so as to retrieve all relevant primary studies in this regard. Journal and conference papers between the year 2003 and 2015 were considered since the first known OSS quality model emerged in 2003. A total of 19 OSS quality assessment model papers were selected. To select these models we have developed assessment criteria to evaluate the quality of the existing studies. Quality assessment models are classified into five categories based on the quality characteristics they possess namely: single-attribute, rounded category, community-only attribute, non-community attribute as well as the non-quality in use models. Our study reflects that software selection based on hierarchical structures is found to be the most popular selection method in the existing OSS quality assessment models. Furthermore, we found that majority (47%) of the existing models do not specify any domain of application. In conclusion, our study will be a valuable contribution to the community and helps the quality assessment model developers in formulating newer models and also to the practitioners (software evaluators) in selecting suitable OSS in the midst of alternatives.

  20. 42 CFR 460.140 - Additional quality assessment activities.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Quality Assessment and Performance Improvement § 460.140 Additional quality...

  1. Assessing the quality of reproductive health services in Egypt via exit interviews.

    PubMed

    Zaky, Hassan H M; Khattab, Hind A S; Galal, Dina

    2007-05-01

    This study assesses the quality of reproductive health services using client satisfaction exit interviews among three groups of primary health care units run by the Ministry of Health and Population of Egypt. Each group applied a different model of intervention. The Ministry will use the results in assessing its reproductive health component in the health sector reform program, and benefits from the strengths of other models of intervention. The sample was selected in two stages. First, a stratified random sampling procedure was used to select the health units. Then the sample of female clients in each health unit was selected using the systematic random approach, whereby one in every two women visiting the unit was approached. All women in the sample coming for reproductive health services were included in the analysis. The results showed that reproductive health beneficiaries at the units implementing the new health sector reform program were more satisfied with the quality of services. Still there were various areas where clients showed significant dissatisfaction, such as waiting time, interior furnishings, cleanliness of the units and consultation time. The study showed that the staff of these units did not provide a conductive social environment as other interventions did. A significant proportion of women expressed their intention to go to private physicians owing to their flexible working hours and variety specializations. Beneficiaries were generally more satisfied with the quality of health services after attending the reformed units than the other types of units, but the generalization did not fully apply. Areas of weakness are identified.

  2. Water Quality Assessment using Satellite Remote Sensing

    NASA Astrophysics Data System (ADS)

    Haque, Saad Ul

    2016-07-01

    The two main global issues related to water are its declining quality and quantity. Population growth, industrialization, increase in agriculture land and urbanization are the main causes upon which the inland water bodies are confronted with the increasing water demand. The quality of surface water has also been degraded in many countries over the past few decades due to the inputs of nutrients and sediments especially in the lakes and reservoirs. Since water is essential for not only meeting the human needs but also to maintain natural ecosystem health and integrity, there are efforts worldwide to assess and restore quality of surface waters. Remote sensing techniques provide a tool for continuous water quality information in order to identify and minimize sources of pollutants that are harmful for human and aquatic life. The proposed methodology is focused on assessing quality of water at selected lakes in Pakistan (Sindh); namely, HUBDAM, KEENJHAR LAKE, HALEEJI and HADEERO. These lakes are drinking water sources for several major cities of Pakistan including Karachi. Satellite imagery of Landsat 7 (ETM+) is used to identify the variation in water quality of these lakes in terms of their optical properties. All bands of Landsat 7 (ETM+) image are analyzed to select only those that may be correlated with some water quality parameters (e.g. suspended solids, chlorophyll a). The Optimum Index Factor (OIF) developed by Chavez et al. (1982) is used for selection of the optimum combination of bands. The OIF is calculated by dividing the sum of standard deviations of any three bands with the sum of their respective correlation coefficients (absolute values). It is assumed that the band with the higher standard deviation contains the higher amount of 'information' than other bands. Therefore, OIF values are ranked and three bands with the highest OIF are selected for the visual interpretation. A color composite image is created using these three bands. The water quality

  3. Assessment of eye lens doses for workers during interventional radiology procedures.

    PubMed

    Urboniene, A; Sadzeviciene, E; Ziliukas, J

    2015-07-01

    The assessment of eye lens doses for workers during interventional radiology (IR) procedures was performed using a new eye lens dosemeter. In parallel, the results of routine individual monitoring were analysed and compared with the results obtained from measurements with a new eye lens dosemeter. The eye lens doses were assessed using Hp(3) measured at the level of the eyes and were compared with Hp(10) measured with the whole-body dosemeter above the lead collar. The information about use of protective measures, the number of performed interventional procedures per month and their fluoroscopy time was also collected. The assessment of doses to the lens of the eye was done for 50 IR workers at 9 Lithuanian hospitals for the period of 2012-2013. If the use of lead glasses is not taken into account, the estimated maximum annual dose equivalent to the lens of the eye was 82 mSv. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Increasing the Rigor of Procedural Fidelity Assessment: An Empirical Comparison of Direct Observation and Permanent Product Review Methods

    ERIC Educational Resources Information Center

    Sanetti, Lisa M. Hagermoser; Collier-Meek, Melissa A.

    2014-01-01

    Although it is widely accepted that procedural fidelity data are important for making valid decisions about intervention effectiveness, there is little empirical guidance for researchers and practitioners regarding how to assess procedural fidelity. A first step in moving procedural fidelity assessment research forward is to develop a…

  5. Pre- and postoperative assessment of sinus grafting procedures using cone-beam computed tomography compared with panoramic radiographs.

    PubMed

    Baciut, Mihaela; Hedesiu, Mihaela; Bran, Simion; Jacobs, Reinhilde; Nackaerts, Olivia; Baciut, Grigore

    2013-05-01

    The present study evaluated the clinical validity of cone-beam computed tomography (CBCT) scans in comparison to panoramic radiographs regarding preoperative implant planning in combination with sinus grafting procedures. Preoperative assessment of the maxillary sinuses and implant planning using panoramic radiographs and CBCT scans was performed on 16 sinuses (13 patients) and comprised choice of treatment, timing of implant placement, sinus morphology, level of confidence, complication prediction and graft volume assessment. Six examiners were involved in the study. In the majority of cases there was a concordance between the treatment type based on either panoramic radiographs or CBCT. If any difference was found, this was due to an overestimation of bone quantity and quality on panoramic radiographs. The assessment of sinus morphology showed a significantly higher detection rate of sinus mucosal hypertrophy on CBCT. The most appealing result is a significant increase in surgical confidence and a significantly better prediction of complications when using CBCT. A preoperative planning based on CBCT seems to improve sinus diagnostics and surgical confidence. © 2012 John Wiley & Sons A/S.

  6. Higher Education Quality Assessment in China: An Impact Study

    ERIC Educational Resources Information Center

    Liu, Shuiyun

    2015-01-01

    This research analyses an external higher education quality assessment scheme in China, namely, the Quality Assessment of Undergraduate Education (QAUE) scheme. Case studies were conducted in three Chinese universities with different statuses. Analysis shows that the evaluated institutions responded to the external requirements of the QAUE…

  7. Guidelines for collecting and processing samples of stream bed sediment for analysis of trace elements and organic contaminants for the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Shelton, Larry R.; Capel, Paul D.

    1994-01-01

    A major component of the U.S. Geological Survey's National Water-Quality Assessment program is to assess the occurrence and distribution of trace elements and organic contaminants in streams. The first phase of the strategy for the assessment is to analyze samples of bed sediments from depositional zones. Fine-grained particles deposited in these zones are natural accumulators of trace elements and hydrophobic organic compounds. For the information to be comparable among studies in many different parts of the Nation, strategies for selecting stream sites and depositional zones are critical. Fine-grained surficial sediments are obtained from several depositional zones within a stream reach and composited to yield a sample representing average conditions. Sample collection and processing must be done consistently and by procedures specifically designed to separate the fine material into fractions that yield uncontaminated samples for trace-level analytes in the laboratory. Special coring samplers and other instruments made of Teflon are used for collection. Samples are processed through a 2.0-millimeter stainless-steel mesh sieve for organic contaminate analysis and a 63-micrometer nylon-cloth sieve for trace-element analysis. Quality assurance is maintained by strict collection and processing procedures, duplicate samplings, and a rigid cleaning procedure.

  8. Assessing Personal Qualities in Medical School Admissions.

    ERIC Educational Resources Information Center

    Albanese, Mark A.; Snow, Mikel H.; Skochelak, Susan E.; Huggett, Kathryn N.; Farrell, Philip M.

    2003-01-01

    Analyzes the challenges to using academic measures (MCAT scores and GPAs) as thresholds for medical school admissions and, for applicants exceeding the threshold, using personal qualities for admission decisions; reviews the literature on using the medical school interview and other admission data to assess personal qualities of applicants;…

  9. Portable Imagery Quality Assessment Test Field for Uav Sensors

    NASA Astrophysics Data System (ADS)

    Dąbrowski, R.; Jenerowicz, A.

    2015-08-01

    Nowadays the imagery data acquired from UAV sensors are the main source of all data used in various remote sensing applications, photogrammetry projects and in imagery intelligence (IMINT) as well as in other tasks as decision support. Therefore quality assessment of such imagery is an important task. The research team from Military University of Technology, Faculty of Civil Engineering and Geodesy, Geodesy Institute, Department of Remote Sensing and Photogrammetry has designed and prepared special test field- The Portable Imagery Quality Assessment Test Field (PIQuAT) that provides quality assessment in field conditions of images obtained with sensors mounted on UAVs. The PIQuAT consists of 6 individual segments, when combined allow for determine radiometric, spectral and spatial resolution of images acquired from UAVs. All segments of the PIQuAT can be used together in various configurations or independently. All elements of The Portable Imagery Quality Assessment Test Field were tested in laboratory conditions in terms of their radiometry and spectral reflectance characteristics.

  10. Analysis of quality raw data of second generation sequencers with Quality Assessment Software.

    PubMed

    Ramos, Rommel Tj; Carneiro, Adriana R; Baumbach, Jan; Azevedo, Vasco; Schneider, Maria Pc; Silva, Artur

    2011-04-18

    Second generation technologies have advantages over Sanger; however, they have resulted in new challenges for the genome construction process, especially because of the small size of the reads, despite the high degree of coverage. Independent of the program chosen for the construction process, DNA sequences are superimposed, based on identity, to extend the reads, generating contigs; mismatches indicate a lack of homology and are not included. This process improves our confidence in the sequences that are generated. We developed Quality Assessment Software, with which one can review graphs showing the distribution of quality values from the sequencing reads. This software allow us to adopt more stringent quality standards for sequence data, based on quality-graph analysis and estimated coverage after applying the quality filter, providing acceptable sequence coverage for genome construction from short reads. Quality filtering is a fundamental step in the process of constructing genomes, as it reduces the frequency of incorrect alignments that are caused by measuring errors, which can occur during the construction process due to the size of the reads, provoking misassemblies. Application of quality filters to sequence data, using the software Quality Assessment, along with graphing analyses, provided greater precision in the definition of cutoff parameters, which increased the accuracy of genome construction.

  11. Development and Validation of a Consumer Quality Assessment Instrument for Dentistry.

    ERIC Educational Resources Information Center

    Johnson, Jeffrey D.; And Others

    1990-01-01

    This paper reviews the literature on consumer involvement in dental quality assessment, argues for inclusion of this information in quality assessment measures, outlines a conceptual model for measuring dental consumer quality assessment, and presents data relating to the development and validation of an instrument based on the conceptual model.…

  12. Baseline Assessment of 25-Hydroxyvitamin D Reference Material and Proficiency Testing/External Quality Assurance Material Commutability: A Vitamin D Standardization Program Study.

    PubMed

    Phinney, Karen W; Sempos, Christopher T; Tai, Susan S-C; Camara, Johanna E; Wise, Stephen A; Eckfeldt, John H; Hoofnagle, Andrew N; Carter, Graham D; Jones, Julia; Myers, Gary L; Durazo-Arvizu, Ramon; Miller, W Greg; Bachmann, Lorin M; Young, Ian S; Pettit, Juanita; Caldwell, Grahame; Liu, Andrew; Brooks, Stephen P J; Sarafin, Kurtis; Thamm, Michael; Mensink, Gert B M; Busch, Markus; Rabenberg, Martina; Cashman, Kevin D; Kiely, Mairead; Galvin, Karen; Zhang, Joy Y; Kinsella, Michael; Oh, Kyungwon; Lee, Sun-Wha; Jung, Chae L; Cox, Lorna; Goldberg, Gail; Guberg, Kate; Meadows, Sarah; Prentice, Ann; Tian, Lu; Brannon, Patsy M; Lucas, Robyn M; Crump, Peter M; Cavalier, Etienne; Merkel, Joyce; Betz, Joseph M

    2017-09-01

    The Vitamin D Standardization Program (VDSP) coordinated a study in 2012 to assess the commutability of reference materials and proficiency testing/external quality assurance materials for total 25-hydroxyvitamin D [25(OH)D] in human serum, the primary indicator of vitamin D status. A set of 50 single-donor serum samples as well as 17 reference and proficiency testing/external quality assessment materials were analyzed by participating laboratories that used either immunoassay or LC-MS methods for total 25(OH)D. The commutability test materials included National Institute of Standards and Technology Standard Reference Material 972a Vitamin D Metabolites in Human Serum as well as materials from the College of American Pathologists and the Vitamin D External Quality Assessment Scheme. Study protocols and data analysis procedures were in accordance with Clinical and Laboratory Standards Institute guidelines. The majority of the test materials were found to be commutable with the methods used in this commutability study. These results provide guidance for laboratories needing to choose appropriate reference materials and select proficiency or external quality assessment programs and will serve as a foundation for additional VDSP studies.

  13. Assessing the quality of healthcare provided to children.

    PubMed

    Mangione-Smith, R; McGlynn, E A

    1998-10-01

    To present a conceptual framework for evaluating quality of care for children and adolescents, summarize the key issues related to developing measures to assess pediatric quality of care, examine some existing measures, and present evidence about their current level of performance. Assessing the quality of care for children poses many challenges not encountered when making these measurements in the adult population. Children and adolescents (from this point forward referred to collectively as children unless differentiation is necessary) differ from adults in two clinically important ways (Jameson and Wehr 1993): (1) their normal developmental trajectory is characterized by change, and (2) they have differential morbidity. These factors contribute to the limitations encountered when developing measures to assess the quality of care for children. The movement of a child through the various stages of development makes it difficult to establish what constitutes a "normal" outcome and by extension what constitutes a poor outcome. Additionally, salient developmental outcomes that result from poor quality of care may not be observed for several years. This implies that poor outcomes may be observed when the child is receiving care from a delivery system other than the one that provided the low-quality care. Attributing the suboptimal outcome to the new delivery system would be inappropriate. Differential morbidity refers to the fact that the type, prevalence, and severity of illness experienced by children is measurably different from that observed in adults. Most children experience numerous self-limited illness of mild severity. A minority of children suffer from markedly more severe diseases. Thus, condition-specific measures in children are problematic to implement for routine assessments because of the extremely low incidence and prevalence of most severe pediatric diseases (Halfon 1996). However, children with these conditions are potentially the segment of the

  14. A comprehensive framework for data quality assessment in CER.

    PubMed

    Holve, Erin; Kahn, Michael; Nahm, Meredith; Ryan, Patrick; Weiskopf, Nicole

    2013-01-01

    The panel addresses the urgent need to ensure that comparative effectiveness research (CER) findings derived from diverse and distributed data sources are based on credible, high-quality data; and that the methods used to assess and report data quality are consistent, comprehensive, and available to data consumers. The panel consists of representatives from four teams leveraging electronic clinical data for CER, patient centered outcomes research (PCOR), and quality improvement (QI) and seeks to change the current paradigm where data quality assessment (DQA) is performed "behind the scenes" using one-off project specific methods. The panelists will present their process of harmonizing existing models for describing and measuring clinical data quality and will describe a comprehensive integrated framework for assessing and reporting DQA findings. The collaborative project is supported by the Electronic Data Methods (EDM) Forum, a three-year grant from the Agency for Healthcare Research and Quality (AHRQ) to facilitate learning and foster collaboration across a set of CER, PCOR, and QI projects designed to build infrastructure and methods for collecting and analyzing prospective data from electronic clinical data .

  15. The monitoring and data quality assessment of the ATLAS liquid argon calorimeter

    NASA Astrophysics Data System (ADS)

    Simard, Olivier; ATLAS Liquid Argon Calorimeter Group

    2015-02-01

    The ATLAS experiment is designed to study the proton-proton (pp) collisions produced at the Large Hadron Collider (LHC) at CERN. Liquid argon (LAr) sampling calorimeters are used for all electromagnetic calorimetry in the pseudo-rapidity region |η| < 3.2, as well as for hadronic calorimetry in the range 1.5 < |η| < 4.9. The electromagnetic calorimeters use lead as passive material and are characterized by an accordion geometry that allows a fast and uniform response without azimuthal gaps. Copper and tungsten were chosen as passive material for the hadronic calorimetry; while a classic parallel-plate geometry was adopted at large polar angles, an innovative design based on cylindrical electrodes with thin liquid argon gaps is employed at low angles, where the particle flux is higher. All detectors are housed in three cryostats maintained at about 88.5 K. The 182,468 cells are read out via front-end boards housed in on-detector crates that also contain monitoring, calibration, trigger and timing boards. In the first three years of LHC operation, approximately 27 fb-1 of pp collision data were collected at centre-of-mass energies of 7-8 TeV. Throughout this period, the calorimeter consistently operated with performances very close to specifications, with high data-taking efficiency. This is in large part due to a sophisticated data monitoring procedure designed to quickly identify issues that would degrade the detector performance, to ensure that only the best quality data are used for physics analysis. After a description of the detector design, main characteristics and operation principles, this paper details the data quality assessment procedures developed during the 2011 and 2012 LHC data-taking periods, when more than 98% of the luminosity recorded by ATLAS had high quality LAr calorimeter data suitable for physics analysis.

  16. Improving L2 Reading Comprehension through Emotionalized Dynamic Assessment Procedures

    ERIC Educational Resources Information Center

    Abdolrezapour, Parisa

    2017-01-01

    The paper reports a study on an emotionally-loaded dynamic assessment procedure used with Iranian EFL learners. It focuses on the effect of using emotional intelligence characteristics (based on Goleman's framework) as a tool for motivating learners while performing reading tasks. The study with 50 intermediate learners aged 12-15 used three…

  17. Development of RAD-Score: A Tool to Assess the Procedural Competence of Diagnostic Radiology Residents.

    PubMed

    Isupov, Inga; McInnes, Matthew D F; Hamstra, Stan J; Doherty, Geoffrey; Gupta, Ashish; Peddle, Susan; Jibri, Zaid; Rakhra, Kawan; Hibbert, Rebecca M

    2017-04-01

    The purpose of this study is to develop a tool to assess the procedural competence of radiology trainees, with sources of evidence gathered from five categories to support the construct validity of tool: content, response process, internal structure, relations to other variables, and consequences. A pilot form for assessing procedural competence among radiology residents, known as the RAD-Score tool, was developed by evaluating published literature and using a modified Delphi procedure involving a group of local content experts. The pilot version of the tool was tested by seven radiology department faculty members who evaluated procedures performed by 25 residents at one institution between October 2014 and June 2015. Residents were evaluated while performing multiple procedures in both clinical and simulation settings. The main outcome measure was the percentage of residents who were considered ready to perform procedures independently, with testing conducted to determine differences between levels of training. A total of 105 forms (for 52 procedures performed in a clinical setting and 53 procedures performed in a simulation setting) were collected for a variety of procedures (eight vascular or interventional, 42 body, 12 musculoskeletal, 23 chest, and 20 breast procedures). A statistically significant difference was noted in the percentage of trainees who were rated as being ready to perform a procedure independently (in postgraduate year [PGY] 2, 12% of residents; in PGY3, 61%; in PGY4, 85%; and in PGY5, 88%; p < 0.05); this difference persisted in the clinical and simulation settings. User feedback and psychometric analysis were used to create a final version of the form. This prospective study describes the successful development of a tool for assessing the procedural competence of radiology trainees with high levels of construct validity in multiple domains. Implementation of the tool in the radiology residency curriculum is planned and can play an

  18. Adaptive Assessment for Nonacademic Secondary Reading.

    ERIC Educational Resources Information Center

    Hittleman, Daniel R.

    Adaptive assessment procedures are a means of determining the quality of a reader's performance in a variety of reading situations and on a variety of written materials. Such procedures are consistent with the idea that there are functional competencies which change with the reading task. Adaptive assessment takes into account that a lack of…

  19. Chloral hydrate as a sedating agent for neurodiagnostic procedures in children.

    PubMed

    Fong, Choong Yi; Tay, Chee Geap; Ong, Lai Choo; Lai, Nai Ming

    2017-11-03

    Paediatric neurodiagnostic investigations, including brain neuroimaging and electroencephalography (EEG), play an important role in the assessment of neurodevelopmental disorders. The use of an appropriate sedative agent is important to ensure the successful completion of the neurodiagnostic procedures, particularly in children, who are usually unable to remain still throughout the procedure. To assess the effectiveness and adverse effects of chloral hydrate as a sedative agent for non-invasive neurodiagnostic procedures in children. We used the standard search strategy of the Cochrane Epilepsy Group. We searched MEDLINE (OVID SP) (1950 to July 2017), the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library, Issue 7, 2017), Embase (1980 to July 2017), and the Cochrane Epilepsy Group Specialized Register (via CENTRAL) using a combination of keywords and MeSH headings. We included randomised controlled trials that assessed chloral hydrate agent against other sedative agent(s), non-drug agent(s), or placebo for children undergoing non-invasive neurodiagnostic procedures. Two review authors independently assessed the studies for their eligibility, extracted data, and assessed risk of bias. Results were expressed in terms of risk ratio (RR) for dichotomous data, mean difference (MD) for continuous data, with 95% confidence intervals (CIs). We included 13 studies with a total of 2390 children. The studies were all conducted in hospitals that provided neurodiagnostic services. Most studies assessed the proportion of sedation failure during the neurodiagnostic procedure, time for adequate sedation, and potential adverse effects associated with the sedative agent.The methodological quality of the included studies was mixed, as reflected by a wide variation in their 'Risk of bias' profiles. Blinding of the participants and personnel was not achieved in most of the included studies, and three of the 13 studies had high risk of bias for selective

  20. Quality Assurance--Best Practices for Assessing Online Programs

    ERIC Educational Resources Information Center

    Wang, Qi

    2006-01-01

    Educators have long sought to define quality in education. With the proliferation of distance education and online learning powered by the Internet, the tasks required to assess the quality of online programs become even more challenging. To assist educators and institutions in search of quality assurance methods to continuously improve their…

  1. Rapid quality assessment of Radix Aconiti Preparata using direct analysis in real time mass spectrometry.

    PubMed

    Zhu, Hongbin; Wang, Chunyan; Qi, Yao; Song, Fengrui; Liu, Zhiqiang; Liu, Shuying

    2012-11-08

    This study presents a novel and rapid method to identify chemical markers for the quality control of Radix Aconiti Preparata, a world widely used traditional herbal medicine. In the method, the samples with a fast extraction procedure were analyzed using direct analysis in real time mass spectrometry (DART MS) combined with multivariate data analysis. At present, the quality assessment approach of Radix Aconiti Preparata was based on the two processing methods recorded in Chinese Pharmacopoeia for the purpose of reducing the toxicity of Radix Aconiti and ensuring its clinical therapeutic efficacy. In order to ensure the safety and effectivity in clinical use, the processing degree of Radix Aconiti should be well controlled and assessed. In the paper, hierarchical cluster analysis and principal component analysis were performed to evaluate the DART MS data of Radix Aconiti Preparata samples in different processing times. The results showed that the well processed Radix Aconiti Preparata, unqualified processed and the raw Radix Aconiti could be clustered reasonably corresponding to their constituents. The loading plot shows that the main chemical markers having the most influence on the discrimination amongst the qualified and unqualified samples were mainly some monoester diterpenoid aconitines and diester diterpenoid aconitines, i.e. benzoylmesaconine, hypaconitine, mesaconitine, neoline, benzoylhypaconine, benzoylaconine, fuziline, aconitine and 10-OH-mesaconitine. The established DART MS approach in combination with multivariate data analysis provides a very flexible and reliable method for quality assessment of toxic herbal medicine. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. [Domestic and international trends concerning allowable limits of error in external quality assessment scheme].

    PubMed

    Hosogaya, Shigemi; Ozaki, Yukio

    2005-06-01

    Many external quality assessment schemes (EQAS) are performed to support quality improvement of the services provided by participating laboratories for the benefits of patients. The EQAS organizer shall be responsible for ensuring that the method of evaluation is appropriate for maintenance of the credibility of the schemes. Procedures to evaluate each participating laboratory are gradually being standardized. In most cases of EQAS, the peer group mean is used as a target of accuracy, and the peer group standard deviation is used as a criterion for inter-laboratory variation. On the other hand, Fraser CG, et al. proposed desirable quality specifications for any imprecision and inaccuracies, which were derived from inter- and intra-biologic variations. We also proposed allowable limits of analytical error, being less than one-half of the average intra-individual variation for evaluation of imprecision, and less than one-quarter of the inter- plus intra-individual variation for evaluation of inaccuracy. When expressed in coefficient of variation terms, these allowable limits may be applied at a wide range of levels of quantity.

  3. Racial/Ethnic Disparities in Perioperative Outcomes of Major Procedures: Results From the National Surgical Quality Improvement Program.

    PubMed

    Ravi, Praful; Sood, Akshay; Schmid, Marianne; Abdollah, Firas; Sammon, Jesse D; Sun, Maxine; Klett, Dane E; Varda, Briony; Peabody, James O; Menon, Mani; Kibel, Adam S; Nguyen, Paul L; Trinh, Quoc-Dien

    2015-12-01

    To determine the association between race/ethnicity and perioperative outcomes in individuals undergoing major oncologic and nononcologic surgical procedures in the United States. Prior work has shown that there are significant racial/ethnic disparities in perioperative outcomes after several types of major cardiac, general, vascular, orthopedic, and cancer surgical procedures. However, recent evidence suggests attenuation of these racial/ethnic differences, particularly at academic institutions. We utilized the American College of Surgeons National Surgical Quality Improvement Program database to identify 142,344 patients undergoing one of the 16 major cancer and noncancer surgical procedures between 2005 and 2011. Eighty-five percent of the cohort was white, with black and Hispanic individuals comprising 8% and 4%, respectively. In multivariable analyses, black patients had greater odds of experiencing prolonged length of stay after 10 of the 16 procedures studied (all P < 0.05), though there was no disparity in odds of 30-day mortality after any surgery. Hispanics were more likely to experience prolonged length of stay after 5 surgical procedures (all P < 0.04), and were at greater odds of dying within 30 days after colectomy, heart valve repair/replacement, or abdominal aortic aneurysm repair (all P < 0.03). Fewer disparities were observed for Hispanics, than for black patients, and also for cancer, than for noncancer surgical procedures. Important racial/ethnic disparities in perioperative outcomes were observed among patients undergoing major cancer and noncancer surgical procedures at American College of Surgeons National Surgical Quality Improvement Program institutions. There were fewer disparities among individuals undergoing cancer surgery, though black patients, in particular, were more likely to experience prolonged length of stay.

  4. Image quality assessment metric for frame accumulated image

    NASA Astrophysics Data System (ADS)

    Yu, Jianping; Li, Gang; Wang, Shaohui; Lin, Ling

    2018-01-01

    The medical image quality determines the accuracy of diagnosis, and the gray-scale resolution is an important parameter to measure image quality. But current objective metrics are not very suitable for assessing medical images obtained by frame accumulation technology. Little attention was paid to the gray-scale resolution, basically based on spatial resolution and limited to the 256 level gray scale of the existing display device. Thus, this paper proposes a metric, "mean signal-to-noise ratio" (MSNR) based on signal-to-noise in order to be more reasonable to evaluate frame accumulated medical image quality. We demonstrate its potential application through a series of images under a constant illumination signal. Here, the mean image of enough images was regarded as the reference image. Several groups of images by different frame accumulation and their MSNR were calculated. The results of the experiment show that, compared with other quality assessment methods, the metric is simpler, more effective, and more suitable for assessing frame accumulated images that surpass the gray scale and precision of the original image.

  5. DOGMA: domain-based transcriptome and proteome quality assessment.

    PubMed

    Dohmen, Elias; Kremer, Lukas P M; Bornberg-Bauer, Erich; Kemena, Carsten

    2016-09-01

    Genome studies have become cheaper and easier than ever before, due to the decreased costs of high-throughput sequencing and the free availability of analysis software. However, the quality of genome or transcriptome assemblies can vary a lot. Therefore, quality assessment of assemblies and annotations are crucial aspects of genome analysis pipelines. We developed DOGMA, a program for fast and easy quality assessment of transcriptome and proteome data based on conserved protein domains. DOGMA measures the completeness of a given transcriptome or proteome and provides information about domain content for further analysis. DOGMA provides a very fast way to do quality assessment within seconds. DOGMA is implemented in Python and published under GNU GPL v.3 license. The source code is available on https://ebbgit.uni-muenster.de/domainWorld/DOGMA/ CONTACTS: e.dohmen@wwu.de or c.kemena@wwu.de Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  6. Improving the quality of discrete-choice experiments in health: how can we assess validity and reliability?

    PubMed

    Janssen, Ellen M; Marshall, Deborah A; Hauber, A Brett; Bridges, John F P

    2017-12-01

    The recent endorsement of discrete-choice experiments (DCEs) and other stated-preference methods by regulatory and health technology assessment (HTA) agencies has placed a greater focus on demonstrating the validity and reliability of preference results. Areas covered: We present a practical overview of tests of validity and reliability that have been applied in the health DCE literature and explore other study qualities of DCEs. From the published literature, we identify a variety of methods to assess the validity and reliability of DCEs. We conceptualize these methods to create a conceptual model with four domains: measurement validity, measurement reliability, choice validity, and choice reliability. Each domain consists of three categories that can be assessed using one to four procedures (for a total of 24 tests). We present how these tests have been applied in the literature and direct readers to applications of these tests in the health DCE literature. Based on a stakeholder engagement exercise, we consider the importance of study characteristics beyond traditional concepts of validity and reliability. Expert commentary: We discuss study design considerations to assess the validity and reliability of a DCE, consider limitations to the current application of tests, and discuss future work to consider the quality of DCEs in healthcare.

  7. High-performance thin layer chromatography to assess pharmaceutical product quality.

    PubMed

    Kaale, Eliangiringa; Manyanga, Vicky; Makori, Narsis; Jenkins, David; Michael Hope, Samuel; Layloff, Thomas

    2014-06-01

    To assess the sustainability, robustness and economic advantages of high-performance thin layer chromatography (HPTLC) for quality control of pharmaceutical products. We compared three laboratories where three lots of cotrimoxazole tablets were assessed using different techniques for quantifying the active ingredient. The average assay relative standard deviation for the three lots was 1.2 with a range of 0.65-2.0. High-performance thin layer chromatography assessments are yielding valid results suitable for assessing product quality. The local pharmaceutical manufacturer had evolved the capacity to produce very high quality products. © 2014 John Wiley & Sons Ltd.

  8. Indoor Air Quality Building Education and Assessment Model

    EPA Pesticide Factsheets

    The Indoor Air Quality Building Education and Assessment Model (I-BEAM), released in 2002, is a guidance tool designed for use by building professionals and others interested in indoor air quality in commercial buildings.

  9. Ground-water-quality assessment of the Carson River basin, Nevada and California; analysis of available water-quality data through 1987

    USGS Publications Warehouse

    Welch, A.H.; Plume, R.W.; Frick, E.A.; Hughes, J.L.

    1989-01-01

    Data on groundwater quality, hydrogeology, and land and water use for the Carson River basin, Nevada and California were analyzed as part of the U. S. Geological Survey National Water-Quality Assessment program. The basin consists of six hydrographic areas--a mountainous headwaters area and five downstream areas interconnected by the Carson River. Each valley contains one or more basin-fill aquifers. The data on groundwater quality came from several agencies and were screened to verify site location and to avoid analyses of treated water. The screened data are stored in the U. S. Geological Survey National Water Information System data base. Differences in sample-collection and preservation procedures among some of the data-collection agencies restrict use of the data to a descriptive analysis. Drinking water standards were employed as the basis for evaluating reported concentrations. Frequencies with which primary or secondary standards are exceeded increase from upstream parts of the basin to downstream parts. Primary standards commonly exceeded are fluoride in upstream areas and arsenic and fluoride in downstream areas. Secondary standards commonly exceeded are iron and manganese in upstream areas and chloride, dissolved solids, iron, manganese, and sulfate in downstream areas. The poorer-quality groundwater generally is a result of natural geochemical reactions, rather than the introduction of chemicals by man. Limited data indicate, however , that manmade organic compounds are present, mostly at or near urban land. (USGS)

  10. [Quality assurance and quality management in intensive care].

    PubMed

    Notz, K; Dubb, R; Kaltwasser, A; Hermes, C; Pfeffer, S

    2015-11-01

    Treatment success in hospitals, particularly in intensive care units, is directly tied to quality of structure, process, and outcomes. Technological and medical advancements lead to ever more complex treatment situations with highly specialized tasks in intensive care nursing. Quality criteria that can be used to describe and correctly measure those highly complex multiprofessional situations have only been recently developed and put into practice.In this article, it will be shown how quality in multiprofessional teams can be definded and assessed in daily clinical practice. Core aspects are the choice of a nursing theory, quality assurance measures, and quality management. One possible option of quality assurance is the use of standard operating procedures (SOPs). Quality can ultimately only be achieved if professional groups think beyond their boundaries, minimize errors, and establish and live out instructions and SOPs.

  11. A novel, fuzzy-based air quality index (FAQI) for air quality assessment

    NASA Astrophysics Data System (ADS)

    Sowlat, Mohammad Hossein; Gharibi, Hamed; Yunesian, Masud; Tayefeh Mahmoudi, Maryam; Lotfi, Saeedeh

    2011-04-01

    The ever increasing level of air pollution in most areas of the world has led to development of a variety of air quality indices for estimation of health effects of air pollution, though the indices have their own limitations such as high levels of subjectivity. Present study, therefore, aimed at developing a novel, fuzzy-based air quality index (FAQI ) to handle such limitations. The index developed by present study is based on fuzzy logic that is considered as one of the most common computational methods of artificial intelligence. In addition to criteria air pollutants (i.e. CO, SO 2, PM 10, O 3, NO 2), benzene, toluene, ethylbenzene, xylene, and 1,3-butadiene were also taken into account in the index proposed, because of their considerable health effects. Different weighting factors were then assigned to each pollutant according to its priority. Trapezoidal membership functions were employed for classifications and the final index consisted of 72 inference rules. To assess the performance of the index, a case study was carried out employing air quality data at five different sampling stations in Tehran, Iran, from January 2008 to December 2009, results of which were then compared to the results obtained from USEPA air quality index (AQI). According to the results from present study, fuzzy-based air quality index is a comprehensive tool for classification of air quality and tends to produce accurate results. Therefore, it can be considered useful, reliable, and suitable for consideration by local authorities in air quality assessment and management schemes. Fuzzy-based air quality index (FAQI).

  12. Assessment of three medical and research laboratories using WHO AFRO_SLIPTA Quality Standards in Southwestern Uganda: a long way to go.

    PubMed

    Taremwa, Ivan Mugisha; Ampaire, Lucas; Iramiot, Jacob; Muhwezi, Obed; Matte, Aloysius; Itabangi, Herbert; Mbabazi, Hope; Atwebembeire, Jeninah; Kamwine, Monicah; Katawera, Victoria; Mbalibulha, Yona; Orikiriza, Patrick; Boum, Yap

    2017-01-01

    While the laboratory represents more than 70% of clinical diagnosis and patient management, access to reliable and quality laboratory diagnostics in sub-Saharan Africa remains a challenge. To gain knowledge and suggest evidence based interventions towards laboratory improvement in Southwestern Uganda, we assessed the baseline laboratory quality standards in three medical and research laboratories in Southwestern Uganda. We conducted a cross sectional survey from October, 2013 to April, 2014. Selected laboratories, including one private research, one private for profit and one public laboratory, were assessed using the WHO AFRO_SLIPTA checklist and baseline scores were determined. The three laboratories assessed met basic facility requirements, had trained personnel, and safety measures in place. Sample reception was properly designed and executed with a well designated chain of custody. All laboratories had sufficient equipment for the nature of work they were involved in. However, we found that standard operating procedures were incomplete in all three laboratories, lack of quality audit schemes by two laboratories and only one laboratory enrolled into external quality assurance schemes. The SLIPTA scores were one star for the research laboratory and no star for both the public and private-for-profit laboratories. While most of the laboratory systems were in place, the low scores obtained by the assessed laboratories reflect the need for improvement to reach standards of quality assured diagnostics in the region. Therefore, routine mentorship and regional supportive supervision are necessary to increase the quality of laboratory services.

  13. [Quality evaluation of the orthodontic practice for certification by ISO 9001. A procedure beneficial for medical, medico-dental or hospital service].

    PubMed

    Becker, G

    2001-01-01

    The accreditation of the ISO 9001 certification (ISO = International Standard Organization) is an external evaluation procedure carried out by independent experts, whose object is the analysis of the operational methods and practices of a medical care facility (e.g. hospital, private clinic, general practitioner's or dentist's practice) which decided to assume the concept, implementation and control of its own quality policy. The whole accreditation procedure represents the basic structure of a continuous dynamic progressiveness within a cabinet eager to offer outstanding quality. Moreover, it guarantees active and voluntary participation of every single member of the medical administration or technical team involved in the realization of this primary objective. In other words, we are talking about a very strong dynamic innovation leading to a change of views and the improvement of communication means, while simultaneously enhancing the security and quality aspects of medical care. The continuous guarantee of high quality medical care calls for precise planning and systematization of actions. First of all, these actions are defined, analyzed and listed in precise work procedures. As they are defined with the agreement of the whole team, they implicate respect and self control. This requires of course transparency of the treatment methods, whose different steps and procedures are described in detail in a logogramm set up in common.

  14. Effectiveness of HVAC duct cleaning procedures in improving indoor air quality.

    PubMed

    Ahmad, I; Tansel, B; Mitrani, J D

    2001-12-01

    Indoor air quality has become one of the most serious environmental concerns as an average person spends about 22 hr indoors on a daily basis. The study reported in this article, was conducted to determine the effectiveness of three commercial HVAC (Heating Ventilation Air Conditioning) duct cleaning processes in reducing the level of airborne particulate matter and viable bioaerosols. The three HVAC sanitation processes were: (1) Contact method (use of conventional vacuum cleaning of interior duct surfaces); (2) Air sweep method (use of compressed air to dislodging dirt and debris); (3) Rotary brush method (insertion of a rotary brush into the ductwork to agitate and dislodge the debris). Effectiveness of these sanitation processes was evaluated in terms of airborne particulate and viable bioaerosol concentrations in residential homes. Eight identical homes were selected in the same neighborhood. Two homes were cleaned using each procedure and two were used as controls. It was found that both particle count readings and bioaerosol concentrations were higher when cleaning was being performed than before or after cleaning, which suggests that dirt, debris and other pollutants may become airborne as a result of disturbances caused by the cleaning processes. Particle count readings at 0.3 micron size were found to have increased due to cigarette smoking. Particle counts at 1.0 micron size were reduced due to HVAC duct cleaning. Post-level bioaerosol concentrations, taken two days after cleaning, were found to be lower than the pre-level concentrations suggesting that the cleaning procedures were effective to some extent. Homes cleaned with the Air Sweep procedure showed the highest degree of reduction in bioaerosol concentration among the three procedures investigated.

  15. 40 CFR 63.1107 - Equipment leaks: applicability assessment procedures and methods.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Equipment leaks: applicability assessment procedures and methods. 63.1107 Section 63.1107 Protection of Environment ENVIRONMENTAL PROTECTION... Categories: Generic Maximum Achievable Control Technology Standards § 63.1107 Equipment leaks: applicability...

  16. Virginia Star Quality Initiative: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Virginia's Star Quality Initiative prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators…

  17. Mississippi Quality Step System: QRS Profile. The Child Care Quality Rating System (QRS)Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Mississippi's Quality Step System prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Application…

  18. Methodological Quality Assessment of Meta-analyses in Endodontics.

    PubMed

    Kattan, Sereen; Lee, Su-Min; Kohli, Meetu R; Setzer, Frank C; Karabucak, Bekir

    2018-01-01

    The objectives of this review were to assess the methodological quality of published meta-analyses related to endodontics using the assessment of multiple systematic reviews (AMSTAR) tool and to provide a follow-up to previously published reviews. Three electronic databases were searched for eligible studies according to the inclusion and exclusion criteria: Embase via Ovid, The Cochrane Library, and Scopus. The electronic search was amended by a hand search of 6 dental journals (International Endodontic Journal; Journal of Endodontics; Australian Endodontic Journal; Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology; Endodontics and Dental Traumatology; and Journal of Dental Research). The searches were conducted to include articles published after July 2009, and the deadline for inclusion of the meta-analyses was November 30, 2016. The AMSTAR assessment tool was used to evaluate the methodological quality of all included studies. A total of 36 reports of meta-analyses were included. The overall quality of the meta-analyses reports was found to be medium, with an estimated mean overall AMSTAR score of 7.25 (95% confidence interval, 6.59-7.90). The most poorly assessed areas were providing an a priori design, the assessment of the status of publication, and publication bias. In recent publications in the field of endodontics, the overall quality of the reported meta-analyses is medium according to AMSTAR. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. Water quality assessment of Australian ports using water quality evaluation indices

    PubMed Central

    Jahan, Sayka

    2017-01-01

    Australian ports serve diverse and extensive activities, such as shipping, tourism and fisheries, which may all impact the quality of port water. In this work water quality monitoring at different ports using a range of water quality evaluation indices was applied to assess the port water quality. Seawater samples at 30 stations in the year 2016–2017 from six ports in NSW, Australia, namely Port Jackson, Botany, Kembla, Newcastle, Yamba and Eden, were investigated to determine the physicochemical and biological variables that affect the port water quality. The large datasets obtained were designed to determine the Water Quality Index, Heavy metal Evaluation Index, Contamination Index and newly developed Environmental Water Quality Index. The study revealed medium water quality index and high and medium heavy metal evaluation index at three of the study ports and high contamination index in almost all study ports. Low level dissolved oxygen and higher level of total dissolved solids, turbidity, fecal coliforms, copper, iron, lead, zinc, manganese, cadmium and cobalt are mainly responsible for the poor water qualities of the port areas. Good water quality at the background samples indicated that various port activities are the likely cause for poor water quality inside the port area. PMID:29244876

  20. Machine-Specific Magnetic Resonance Imaging Quality Control Procedures for Stereotactic Radiosurgery Treatment Planning

    PubMed Central

    Taghizadeh, Somayeh; Yang, Claus Chunli; R. Kanakamedala, Madhava; Morris, Bart; Vijayakumar, Srinivasan

    2017-01-01

    Purpose Magnetic resonance (MR) images are necessary for accurate contouring of intracranial targets, determination of gross target volume and evaluation of organs at risk during stereotactic radiosurgery (SRS) treatment planning procedures. Many centers use magnetic resonance imaging (MRI) simulators or regular diagnostic MRI machines for SRS treatment planning; while both types of machine require two stages of quality control (QC), both machine- and patient-specific, before use for SRS, no accepted guidelines for such QC currently exist. This article describes appropriate machine-specific QC procedures for SRS applications. Methods and materials We describe the adaptation of American College of Radiology (ACR)-recommended QC tests using an ACR MRI phantom for SRS treatment planning. In addition, commercial Quasar MRID3D and Quasar GRID3D phantoms were used to evaluate the effects of static magnetic field (B0) inhomogeneity, gradient nonlinearity, and a Leksell G frame (SRS frame) and its accessories on geometrical distortion in MR images. Results QC procedures found in-plane distortions (Maximum = 3.5 mm, Mean = 0.91 mm, Standard deviation = 0.67 mm, >2.5 mm (%) = 2) in X-direction (Maximum = 2.51 mm, Mean = 0.52 mm, Standard deviation = 0.39 mm, > 2.5 mm (%) = 0) and in Y-direction (Maximum = 13. 1 mm , Mean = 2.38 mm, Standard deviation = 2.45 mm, > 2.5 mm (%) = 34) in Z-direction and < 1 mm distortion at a head-sized region of interest. MR images acquired using a Leksell G frame and localization devices showed a mean absolute deviation of 2.3 mm from isocenter. The results of modified ACR tests were all within recommended limits, and baseline measurements have been defined for regular weekly QC tests. Conclusions With appropriate QC procedures in place, it is possible to routinely obtain clinically useful MR images suitable for SRS treatment planning purposes. MRI examination for SRS planning can benefit from the improved localization and planning possible

  1. Machine-Specific Magnetic Resonance Imaging Quality Control Procedures for Stereotactic Radiosurgery Treatment Planning.

    PubMed

    Fatemi, Ali; Taghizadeh, Somayeh; Yang, Claus Chunli; R Kanakamedala, Madhava; Morris, Bart; Vijayakumar, Srinivasan

    2017-12-18

    Purpose Magnetic resonance (MR) images are necessary for accurate contouring of intracranial targets, determination of gross target volume and evaluation of organs at risk during stereotactic radiosurgery (SRS) treatment planning procedures. Many centers use magnetic resonance imaging (MRI) simulators or regular diagnostic MRI machines for SRS treatment planning; while both types of machine require two stages of quality control (QC), both machine- and patient-specific, before use for SRS, no accepted guidelines for such QC currently exist. This article describes appropriate machine-specific QC procedures for SRS applications. Methods and materials We describe the adaptation of American College of Radiology (ACR)-recommended QC tests using an ACR MRI phantom for SRS treatment planning. In addition, commercial Quasar MRID 3D and Quasar GRID 3D phantoms were used to evaluate the effects of static magnetic field (B 0 ) inhomogeneity, gradient nonlinearity, and a Leksell G frame (SRS frame) and its accessories on geometrical distortion in MR images. Results QC procedures found in-plane distortions (Maximum = 3.5 mm, Mean = 0.91 mm, Standard deviation = 0.67 mm, >2.5 mm (%) = 2) in X-direction (Maximum = 2.51 mm, Mean = 0.52 mm, Standard deviation = 0.39 mm, > 2.5 mm (%) = 0) and in Y-direction (Maximum = 13. 1 mm , Mean = 2.38 mm, Standard deviation = 2.45 mm, > 2.5 mm (%) = 34) in Z-direction and < 1 mm distortion at a head-sized region of interest. MR images acquired using a Leksell G frame and localization devices showed a mean absolute deviation of 2.3 mm from isocenter. The results of modified ACR tests were all within recommended limits, and baseline measurements have been defined for regular weekly QC tests. Conclusions With appropriate QC procedures in place, it is possible to routinely obtain clinically useful MR images suitable for SRS treatment planning purposes. MRI examination for SRS planning can benefit from the improved localization and planning

  2. No-reference quality assessment based on visual perception

    NASA Astrophysics Data System (ADS)

    Li, Junshan; Yang, Yawei; Hu, Shuangyan; Zhang, Jiao

    2014-11-01

    The visual quality assessment of images/videos is an ongoing hot research topic, which has become more and more important for numerous image and video processing applications with the rapid development of digital imaging and communication technologies. The goal of image quality assessment (IQA) algorithms is to automatically assess the quality of images/videos in agreement with human quality judgments. Up to now, two kinds of models have been used for IQA, namely full-reference (FR) and no-reference (NR) models. For FR models, IQA algorithms interpret image quality as fidelity or similarity with a perfect image in some perceptual space. However, the reference image is not available in many practical applications, and a NR IQA approach is desired. Considering natural vision as optimized by the millions of years of evolutionary pressure, many methods attempt to achieve consistency in quality prediction by modeling salient physiological and psychological features of the human visual system (HVS). To reach this goal, researchers try to simulate HVS with image sparsity coding and supervised machine learning, which are two main features of HVS. A typical HVS captures the scenes by sparsity coding, and uses experienced knowledge to apperceive objects. In this paper, we propose a novel IQA approach based on visual perception. Firstly, a standard model of HVS is studied and analyzed, and the sparse representation of image is accomplished with the model; and then, the mapping correlation between sparse codes and subjective quality scores is trained with the regression technique of least squaresupport vector machine (LS-SVM), which gains the regressor that can predict the image quality; the visual metric of image is predicted with the trained regressor at last. We validate the performance of proposed approach on Laboratory for Image and Video Engineering (LIVE) database, the specific contents of the type of distortions present in the database are: 227 images of JPEG2000, 233

  3. A quick and reliable procedure for assessing foot alignment in athletes.

    PubMed

    De Michelis Mendonça, Luciana; Bittencourt, Natália Franco Netto; Amaral, Giovanna Mendes; Diniz, Lívia Santos; Souza, Thales Rezende; da Fonseca, Sérgio Teixeira

    2013-01-01

    Quick procedures with proper psychometric properties that can capture the combined alignment of the foot-ankle complex in a position that may be more representative of the status of the lower limb during ground contact are essential for assessing a large group of athletes. The assessed lower limb was positioned with the calcaneus surface facing upward in a way that all of the marks could be seen at the center of the camera display. After guaranteeing maintenance of the foot at 90° of dorsiflexion actively sustained by the athlete, the examiner took the picture of the foot-ankle alignment. Intraclass correlation coefficients ranging from 0.82 to 0.93 demonstrated excellent intratester and intertester reliability for the proposed measurements of forefoot, rearfoot, and shank-forefoot alignments. The intraclass correlation coefficient between the shank-forefoot measures and the sum of the rearfoot and forefoot measures was 0.98, suggesting that the shank-forefoot alignment measures can represent the combined rearfoot and forefoot alignments. This study describes a reliable and practical measurement procedure for rearfoot, forefoot, and shank-forefoot alignments that can be applied to clinical and research situations as a screening procedure for risk factors for lower-limb injuries in athletes.

  4. ICP-Forests (International Co-operative Programme on Assessment and Monitoring of Air Pollution Effects on Forests): Quality Assurance procedure in plant diversity monitoring.

    PubMed

    Allegrini, Maria-Cristina; Canullo, Roberto; Campetella, Giandiego

    2009-04-01

    Knowledge of accuracy and precision rates is particularly important for long-term studies. Vegetation assessments include many sources of error related to overlooking and misidentification, that are usually influenced by some factors, such as cover estimate subjectivity, observer biased species lists and experience of the botanist. The vegetation assessment protocol adopted in the Italian forest monitoring programme (CONECOFOR) contains a Quality Assurance programme. The paper presents the different phases of QA, separates the 5 main critical points of the whole protocol as sources of random or systematic errors. Examples of Measurement Quality Objectives (MQOs) expressed as Data Quality Limits (DQLs) are given for vascular plant cover estimates, in order to establish the reproducibility of the data. Quality control activities were used to determine the "distance" between the surveyor teams and the control team. Selected data were acquired during the training and inter-calibration courses. In particular, an index of average cover by species groups was used to evaluate the random error (CV 4%) as the dispersion around the "true values" of the control team. The systematic error in the evaluation of species composition, caused by overlooking or misidentification of species, was calculated following the pseudo-turnover rate; detailed species censuses on smaller sampling units were accepted as the pseudo-turnover which always fell below the 25% established threshold; species density scores recorded at community level (100 m(2) surface) rarely exceeded that limit.

  5. Quality Assessment of TPB-Based Questionnaires: A Systematic Review

    PubMed Central

    Oluka, Obiageli Crystal; Nie, Shaofa; Sun, Yi

    2014-01-01

    Objective This review is aimed at assessing the quality of questionnaires and their development process based on the theory of planned behavior (TPB) change model. Methods A systematic literature search for studies with the primary aim of TPB-based questionnaire development was conducted in relevant databases between 2002 and 2012 using selected search terms. Ten of 1,034 screened abstracts met the inclusion criteria and were assessed for methodological quality using two different appraisal tools: one for the overall methodological quality of each study and the other developed for the appraisal of the questionnaire content and development process. Both appraisal tools consisted of items regarding the likelihood of bias in each study and were eventually combined to give the overall quality score for each included study. Results 8 of the 10 included studies showed low risk of bias in the overall quality assessment of each study, while 9 of the studies were of high quality based on the quality appraisal of questionnaire content and development process. Conclusion Quality appraisal of the questionnaires in the 10 reviewed studies was successfully conducted, highlighting the top problem areas (including: sample size estimation; inclusion of direct and indirect measures; and inclusion of questions on demographics) in the development of TPB-based questionnaires and the need for researchers to provide a more detailed account of their development process. PMID:24722323

  6. Palm Beach Quality Counts: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Palm Beach's Quality Counts prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for…

  7. Maine Quality for ME: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Maine's Quality for ME prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for Family…

  8. Missouri Quality Rating System: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Missouri's Quality Rating System prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for…

  9. Miami-Dade Quality Counts: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Miami-Dade's Quality Counts prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for…

  10. Indiana Paths to Quality: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Indiana's Paths to Quality prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for…

  11. Teacher Quality and Quality Teaching: Examining the Relationship of a Teacher Assessment to Practice

    ERIC Educational Resources Information Center

    Hill, Heather C.; Umland, Kristin; Litke, Erica; Kapitula, Laura R.

    2012-01-01

    Multiple-choice assessments are frequently used for gauging teacher quality. However, research seldom examines whether results from such assessments generalize to practice. To illuminate this issue, we compare teacher performance on a mathematics assessment, during mathematics instruction, and by student performance on a state assessment. Poor…

  12. Can procedural and substantive elements of decision-making be reconciled in assessments of mental capacity?

    PubMed Central

    Banner, Natalie F.

    2016-01-01

    Capacity legislation aims to protect individual autonomy and avoid undue paternalism as far as possible, partly through ensuring patients are not deemed to lack capacity because they make an unwise decision. To this end, the law employs a procedural test of capacity that excludes substantive judgments about patients’ decisions. However, clinical intuitions about patients’ capacity to make decisions about their treatment often conflict with a strict reading of the legal criteria for assessing capacity, particularly in psychiatry. In this article I argue that this tension arises because the procedural conception of capacity is inadequate and does not reflect the clinical or legal realities of assessing capacity. I propose that conceptualising capacity as having ‘recognisable reasons’ for a treatment decision provides a practical way of legitimately incorporating both procedural and substantive elements of decision-making into assessments of capacity. PMID:27891169

  13. Automatic assessment of the quality of patient positioning in mammography

    NASA Astrophysics Data System (ADS)

    Bülow, Thomas; Meetz, Kirsten; Kutra, Dominik; Netsch, Thomas; Wiemker, Rafael; Bergtholdt, Martin; Sabczynski, Jörg; Wieberneit, Nataly; Freund, Manuela; Schulze-Wenck, Ingrid

    2013-02-01

    Quality assurance has been recognized as crucial for the success of population-based breast cancer screening programs using x-ray mammography. Quality guidelines and criteria have been defined in the US as well as the European Union in order to ensure the quality of breast cancer screening. Taplin et al. report that incorrect positioning of the breast is the major image quality issue in screening mammography. Consequently, guidelines and criteria for correct positioning and for the assessment of the positioning quality in mammograms play an important role in the quality standards. In this paper we present a system for the automatic evaluation of positioning quality in mammography according to the existing standardized criteria. This involves the automatic detection of anatomic landmarks in medio- lateral oblique (MLO) and cranio-caudal (CC) mammograms, namely the pectoral muscle, the mammilla and the infra-mammary fold. Furthermore, the detected landmarks are assessed with respect to their proper presentation in the image. Finally, the geometric relations between the detected landmarks are investigated to assess the positioning quality. This includes the evaluation whether the pectoral muscle is imaged down to the mammilla level, and whether the posterior nipple line diameter of the breast is consistent between the different views (MLO and CC) of the same breast. Results of the computerized assessment are compared to ground truth collected from two expert readers.

  14. Financial and testamentary capacity evaluations: procedures and assessment instruments underneath a functional approach.

    PubMed

    Sousa, Liliana B; Simões, Mário R; Firmino, Horácio; Peisah, Carmelle

    2014-02-01

    Mental health professionals are frequently involved in mental capacity determinations. However, there is a lack of specific measures and well-defined procedures for these evaluations. The main purpose of this paper is to provide a review of financial and testamentary capacity evaluation procedures, including not only the traditional neuropsychological and functional assessment but also the more recently developed forensic assessment instruments (FAIs), which have been developed to provide a specialized answer to legal systems regarding civil competencies. Here the main guidelines, papers, and other references are reviewed in order to achieve a complete and comprehensive selection of instruments used in the assessment of financial and testamentary capacity. Although some specific measures for financial abilities have been developed recently, the same is not true for testamentary capacity. Here are presented several instruments or methodologies for assessing financial and testamentary capacity, including neuropsychological assessment, functional assessment scales, performance based functional assessment instruments, and specific FAIs. FAIs are the only specific instruments intended to provide a specific and direct answer to the assessment of financial capacity based on legal systems. Considering the need to move from a diagnostic to a functional approach in financial and testamentary capacity evaluations, it is essential to consider both general functional examination as well as cognitive functioning.

  15. Research Quality Assessment in Education: Impossible Science, Possible Art?

    ERIC Educational Resources Information Center

    Bridges, David

    2009-01-01

    For better or for worse, the assessment of research quality is one of the primary drivers of the behaviour of the academic community with all sorts of potential for distorting that behaviour. So, if you are going to assess research quality, how do you do it? This article explores some of the problems and possibilities, with particular reference to…

  16. Protein single-model quality assessment by feature-based probability density functions.

    PubMed

    Cao, Renzhi; Cheng, Jianlin

    2016-04-04

    Protein quality assessment (QA) has played an important role in protein structure prediction. We developed a novel single-model quality assessment method-Qprob. Qprob calculates the absolute error for each protein feature value against the true quality scores (i.e. GDT-TS scores) of protein structural models, and uses them to estimate its probability density distribution for quality assessment. Qprob has been blindly tested on the 11th Critical Assessment of Techniques for Protein Structure Prediction (CASP11) as MULTICOM-NOVEL server. The official CASP result shows that Qprob ranks as one of the top single-model QA methods. In addition, Qprob makes contributions to our protein tertiary structure predictor MULTICOM, which is officially ranked 3rd out of 143 predictors. The good performance shows that Qprob is good at assessing the quality of models of hard targets. These results demonstrate that this new probability density distribution based method is effective for protein single-model quality assessment and is useful for protein structure prediction. The webserver of Qprob is available at: http://calla.rnet.missouri.edu/qprob/. The software is now freely available in the web server of Qprob.

  17. A procedural skills OSCE: assessing technical and non-technical skills of internal medicine residents.

    PubMed

    Pugh, Debra; Hamstra, Stanley J; Wood, Timothy J; Humphrey-Murto, Susan; Touchie, Claire; Yudkowsky, Rachel; Bordage, Georges

    2015-03-01

    Internists are required to perform a number of procedures that require mastery of technical and non-technical skills, however, formal assessment of these skills is often lacking. The purpose of this study was to develop, implement, and gather validity evidence for a procedural skills objective structured clinical examination (PS-OSCE) for internal medicine (IM) residents to assess their technical and non-technical skills when performing procedures. Thirty-five first to third-year IM residents participated in a 5-station PS-OSCE, which combined partial task models, standardized patients, and allied health professionals. Formal blueprinting was performed and content experts were used to develop the cases and rating instruments. Examiners underwent a frame-of-reference training session to prepare them for their rater role. Scores were compared by levels of training, experience, and to evaluation data from a non-procedural OSCE (IM-OSCE). Reliability was calculated using Generalizability analyses. Reliabilities for the technical and non-technical scores were 0.68 and 0.76, respectively. Third-year residents scored significantly higher than first-year residents on the technical (73.5 vs. 62.2%) and non-technical (83.2 vs. 75.1%) components of the PS-OSCE (p < 0.05). Residents who had performed the procedures more frequently scored higher on three of the five stations (p < 0.05). There was a moderate disattenuated correlation (r = 0.77) between the IM-OSCE and the technical component of the PS-OSCE scores. The PS-OSCE is a feasible method for assessing multiple competencies related to performing procedures and this study provides validity evidence to support its use as an in-training examination.

  18. Soil structural quality assessment for soil protection regulation

    NASA Astrophysics Data System (ADS)

    Johannes, Alice; Boivin, Pascal

    2017-04-01

    Soil quality assessment is rapidly developing worldwide, though mostly focused on the monitoring of arable land and soil fertility. Soil protection regulations assess soil quality differently, focusing on priority pollutants and threshold values. The soil physical properties are weakly considered, due to lack of consensus and experimental difficulties faced with characterization. Non-disputable, easy to perform and inexpensive methods should be available for environmental regulation to be applied, which is unfortunately not the case. As a consequence, quantitative soil physical protection regulation is not applied, and inexpensive soil physical quality indicators for arable soil management are not available. Overcoming these limitations was the objective of a research project funded by the Swiss federal office for environment (FOEN). The main results and the perspectives of application are given in this presentation. A first step of the research was to characterize soils in a good structural state (reference soils) under different land use. The structural quality was assessed with field expertise and Visual Evaluation of the Soil Structure (VESS), and the physical properties were assessed with Shrinkage analysis. The relationships between the physical properties and the soil constituents were linear and highly determined. They represent the reference properties of the corresponding soils. In a second step, the properties of physically degraded soils were analysed and compared to the reference properties. This allowed defining the most discriminant parameters departing the different structure qualities and their threshold limits. Equivalent properties corresponding to these parameters but inexpensive and easy to determine were defined and tested. More than 90% of the samples were correctly classed with this method, which meets, therefore, the requirements for practical application in regulation. Moreover, result-oriented agri-environmental schemes for soil quality

  19. Exploring the Notion of Quality in Quality Higher Education Assessment in a Collaborative Future

    ERIC Educational Resources Information Center

    Maguire, Kate; Gibbs, Paul

    2013-01-01

    The purpose of this article is to contribute to the debate on the notion of quality in higher education with particular focus on "objectifying through articulation" the assessment of quality by professional experts. The article gives an overview of the differentiations of quality as used in higher education. It explores a substantial…

  20. Quality Assessment of University Studies as a Service: Dimensions and Criteria

    ERIC Educational Resources Information Center

    Pukelyte, Rasa

    2010-01-01

    This article reviews a possibility to assess university studies as a service. University studies have to be of high quality both in their content and in the administrative level. Therefore, quality of studies as a service is an important constituent part of study quality assurance. When assessing quality of university studies as a service, it is…

  1. Influence of carbon dioxide stunning procedure on quality of turkey meat.

    PubMed

    Mauri, S; Guijarro, A; Avilés, C; Peña, F

    2017-08-01

    1. The objective of this study was to evaluate the effect of sex and gas stunning on quality attributes of turkey breast meat. 2. One hundred B.U.T. Premium turkeys (50 males and 50 females) were divided into four groups of 25 animals and subjected to one of two CO 2 stunning procedures: G1 stepwise (step 1: 30% CO 2 , 15 s; step 2: 55% CO 2 , 40 s; step 3: 70% CO 2 , 45 s) or G2 fixed concentration (80% CO 2 , 100 s). The pH and meat colour at 20 min post-mortem, and pH, colour (L*, a*, b*), water holding capacity (WHC), drip loss (DL), cooking loss (CL) and Warner-Bratzler shear force (WBSF) in breast samples at 24 h and 7 d post-mortem were assessed. 3. There were significant differences between stunning groups for pH, meat colour and CL, whereas no significant differences were found for DL and WBSF. Sex had a significant effect on pH and b* and ageing of meat affected pH, colour coordinates, DL and WBSF. 4. It was concluded that the G2 treatment affected negatively the pH value and colour coordinates. However, G2 stunning affected positively the WHC parameters. Female turkeys had better results than males for pH, and the colour of female turkey breast meat was less yellow than male breast meat.

  2. Improving Performance During Image-Guided Procedures

    PubMed Central

    Duncan, James R.; Tabriz, David

    2015-01-01

    Objective Image-guided procedures have become a mainstay of modern health care. This article reviews how human operators process imaging data and use it to plan procedures and make intraprocedural decisions. Methods A series of models from human factors research, communication theory, and organizational learning were applied to the human-machine interface that occupies the center stage during image-guided procedures. Results Together, these models suggest several opportunities for improving performance as follows: 1. Performance will depend not only on the operator’s skill but also on the knowledge embedded in the imaging technology, available tools, and existing protocols. 2. Voluntary movements consist of planning and execution phases. Performance subscores should be developed that assess quality and efficiency during each phase. For procedures involving ionizing radiation (fluoroscopy and computed tomography), radiation metrics can be used to assess performance. 3. At a basic level, these procedures consist of advancing a tool to a specific location within a patient and using the tool. Paradigms from mapping and navigation should be applied to image-guided procedures. 4. Recording the content of the imaging system allows one to reconstruct the stimulus/response cycles that occur during image-guided procedures. Conclusions When compared with traditional “open” procedures, the technology used during image-guided procedures places an imaging system and long thin tools between the operator and the patient. Taking a step back and reexamining how information flows through an imaging system and how actions are conveyed through human-machine interfaces suggest that much can be learned from studying system failures. In the same way that flight data recorders revolutionized accident investigations in aviation, much could be learned from recording video data during image-guided procedures. PMID:24921628

  3. Assessing Question Quality Using NLP

    ERIC Educational Resources Information Center

    Kopp, Kristopher J.; Johnson, Amy M.; Crossley, Scott A.; McNamara, Danielle S.

    2017-01-01

    An NLP algorithm was developed to assess question quality to inform feedback on questions generated by students within iSTART (an intelligent tutoring system that teaches reading strategies). A corpus of 4575 questions was coded using a four-level taxonomy. NLP indices were calculated for each question and machine learning was used to predict…

  4. Video observation of procedural skills for assessment of trabeculectomy performed by residents.

    PubMed

    Hassanpour, Narges; Chen, Rebecca; Baikpour, Masoud; Moghimi, Sasan

    2016-06-01

    The efficacy and sufficiency of a healthcare system is directly related to the knowledge and skills of graduates working in the system. In this regard, many different assessment methods have been proposed to evaluate various skills of the learners. Video Observation of Procedural Skills (VOPS) is one newly-proposed method. In this study we aimed to compare the results of the VOPS method with the more commonly used Direct Observation of Procedural Skills (DOPS). In this prospective study conducted in 2012, all 10 ophthalmology residents of post graduate year 4 were selected for participation. Three months into training in the glaucoma ward, these residents performed trabeculectomy surgery on patients, and their procedural skills were assessed in real time by an expert via the DOPS method. All surgeries were also recorded and later evaluated via the VOPS method by an expert. Bland-Altman plot also was used to compare the two methods and calculating the mean and 95% limit of agreement. Residents have been done a mean of 14.9 ± 3.5 (range 10-20) independent trabeculectomy before the assessments. DOPS grade was positively associated with number of independent trabeculectomy during glaucoma rotation (β=0.227, p = 0.004). The intra-observer reproducibility of VOPS measurements was 0.847 (95% CI: 0.634, 0.961). The mean VOPS grade was significantly lower than the mean DOPS grade (8.4 vs. 8.9, p = 0.02). However, a good correlation was observed between the grades of VOPS and DOPS (r = 0.89, p = 0.001). Bland-Altman analysis demonstrated that all data points fell within the 95% limits of agreement (-1.46, 0.46). The present study showed that VOPS might be considered a feasible, valid, and reliable assessment method for procedural skills of medical students and residents that can be used as an alternative to the DOPS method. However, VOPS might underestimate DOPS in evaluating surgical skills of residents.

  5. Assessment of liver ablation using cone beam computed tomography.

    PubMed

    Abdel-Rehim, Mohamed; Ronot, Maxime; Sibert, Annie; Vilgrain, Valérie

    2015-01-14

    To investigate the feasibility and accuracy of cone beam computed tomography (CBCT) in assessing the ablation zone after liver tumor ablation. Twenty-three patients (17 men and 6 women, range: 45-85 years old, mean age 65 years) with malignant liver tumors underwent ultrasound-guided percutaneous tumor ablation [radiofrequency (n = 14), microwave (n = 9)] followed by intravenous contrast-enhanced CBCT. Baseline multidetector computed tomography (MDCT) and peri-procedural CBCT images were compared. CBCT image quality was assessed as poor, good, or excellent. Image fusion was performed to assess tumor coverage, and quality of fusion was rated as bad, good, or excellent. Ablation zone volumes on peri-procedural CBCT and post-procedural MDCT were compared using the non-parametric paired Wilcoxon t-test. Rate of primary ablation effectiveness was 100%. There were no complications related to ablation. Local tumor recurrence and new liver tumors were found 3 mo after initial treatment in one patient (4%). The ablation zone was identified in 21/23 (91.3%) patients on CBCT. The fusion of baseline MDCT and peri-procedural CBCT images was feasible in all patients and showed satisfactory tumor coverage (at least 5-mm margin). CBCT image quality was poor, good, and excellent in 2 (9%), 8 (35%), and 13 (56%), patients respectively. Registration quality between peri-procedural CBCT and post-procedural MDCT images was good to excellent in 17/23 (74%) patients. The median ablation volume on peri-procedural CBCT and post-procedural MDCT was 30 cm(3) (range: 4-95 cm(3)) and 30 cm(3) (range: 4-124 cm(3)), respectively (P-value > 0.2). There was a good correlation (r = 0.79) between the volumes of the two techniques. Contrast-enhanced CBCT after tumor ablation of the liver allows early assessment of the ablation zone.

  6. Application of Sigma Metrics Analysis for the Assessment and Modification of Quality Control Program in the Clinical Chemistry Laboratory of a Tertiary Care Hospital.

    PubMed

    Iqbal, Sahar; Mustansar, Tazeen

    2017-03-01

    Sigma is a metric that quantifies the performance of a process as a rate of Defects-Per-Million opportunities. In clinical laboratories, sigma metric analysis is used to assess the performance of laboratory process system. Sigma metric is also used as a quality management strategy for a laboratory process to improve the quality by addressing the errors after identification. The aim of this study is to evaluate the errors in quality control of analytical phase of laboratory system by sigma metric. For this purpose sigma metric analysis was done for analytes using the internal and external quality control as quality indicators. Results of sigma metric analysis were used to identify the gaps and need for modification in the strategy of laboratory quality control procedure. Sigma metric was calculated for quality control program of ten clinical chemistry analytes including glucose, chloride, cholesterol, triglyceride, HDL, albumin, direct bilirubin, total bilirubin, protein and creatinine, at two control levels. To calculate the sigma metric imprecision and bias was calculated with internal and external quality control data, respectively. The minimum acceptable performance was considered as 3 sigma. Westgard sigma rules were applied to customize the quality control procedure. Sigma level was found acceptable (≥3) for glucose (L2), cholesterol, triglyceride, HDL, direct bilirubin and creatinine at both levels of control. For rest of the analytes sigma metric was found <3. The lowest value for sigma was found for chloride (1.1) at L2. The highest value of sigma was found for creatinine (10.1) at L3. HDL was found with the highest sigma values at both control levels (8.8 and 8.0 at L2 and L3, respectively). We conclude that analytes with the sigma value <3 are required strict monitoring and modification in quality control procedure. In this study application of sigma rules provided us the practical solution for improved and focused design of QC procedure.

  7. Implementation of a hospital-based quality assessment program for rectal cancer.

    PubMed

    Hendren, Samantha; McKeown, Ellen; Morris, Arden M; Wong, Sandra L; Oerline, Mary; Poe, Lyndia; Campbell, Darrell A; Birkmeyer, Nancy J

    2014-05-01

    Quality improvement programs in Europe have had a markedly beneficial effect on the processes and outcomes of rectal cancer care. The quality of rectal cancer care in the United States is not as well understood, and scalable quality improvement programs have not been developed. The purpose of this article is to describe the implementation of a hospital-based quality assessment program for rectal cancer, targeting both community and academic hospitals. We recruited 10 hospitals from a surgical quality improvement organization. Nurse reviewers were trained to abstract rectal cancer data from hospital medical records, and abstracts were assessed for accuracy. We conducted two surveys to assess the training program and limitations of the data abstraction. We validated data completeness and accuracy by comparing hospital medical record and tumor registry data. Nine of 10 hospitals successfully performed abstractions with ≥ 90% accuracy. Experienced nurse reviewers were challenged by the technical details in operative and pathology reports. Although most variables had less than 10% missing data, outpatient testing information was lacking from some hospitals' inpatient records. This implementation project yielded a final quality assessment program consisting of 20 medical records variables and 11 tumor registry variables. An innovative program linking tumor registry data to quality-improvement data for rectal cancer quality assessment was successfully implemented in 10 hospitals. This data platform and training program can serve as a template for other organizations that are interested in assessing and improving the quality of rectal cancer care. Copyright © 2014 by American Society of Clinical Oncology.

  8. Environmental risk assessment of water quality in harbor areas: a new methodology applied to European ports.

    PubMed

    Gómez, Aina G; Ondiviela, Bárbara; Puente, Araceli; Juanes, José A

    2015-05-15

    This work presents a standard and unified procedure for assessment of environmental risks at the contaminant source level in port aquatic systems. Using this method, port managers and local authorities will be able to hierarchically classify environmental hazards and proceed with the most suitable management actions. This procedure combines rigorously selected parameters and indicators to estimate the environmental risk of each contaminant source based on its probability, consequences and vulnerability. The spatio-temporal variability of multiple stressors (agents) and receptors (endpoints) is taken into account to provide accurate estimations for application of precisely defined measures. The developed methodology is tested on a wide range of different scenarios via application in six European ports. The validation process confirms its usefulness, versatility and adaptability as a management tool for port water quality in Europe and worldwide. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. National Water-Quality Assessment Program: Central Arizona Basins

    USGS Publications Warehouse

    Cordy, Gail E.

    1994-01-01

    In 1991, the U.S. Geological Survey (USGS) began to implement a full-scale National Water-Quality Assessment (NAWQA) program. The long-term goals of the NAWQA program are to describe the status and trends in the quality of a large, representative part of the Nation's surface-water and ground-water resources and to provide a sound, scientific understanding of the primary natural and human factors affecting the quality of these resources. In meeting these goals, the program will produce a wealth of water-quality information that will be useful to policymakers and managers at the National, State, and local levels. Studies of 60 hydrologic systems that include parts of most major river basins and aquifer systems (study-unit investigations) are the building blocks of the national assessment. The 60 study units range in size from 1,000 to about 60,000 mi2 and represent 60 to 70 percent of the Nation's water use and population served by public water supplies. Twenty study-unit investigations were started in 1991, 20 additional studies started in 1994, and 20 more are planned to start in 1997. The Central Arizona Basins study unit began assessment activities in 1994.

  10. MQAPRank: improved global protein model quality assessment by learning-to-rank.

    PubMed

    Jing, Xiaoyang; Dong, Qiwen

    2017-05-25

    Protein structure prediction has achieved a lot of progress during the last few decades and a greater number of models for a certain sequence can be predicted. Consequently, assessing the qualities of predicted protein models in perspective is one of the key components of successful protein structure prediction. Over the past years, a number of methods have been developed to address this issue, which could be roughly divided into three categories: single methods, quasi-single methods and clustering (or consensus) methods. Although these methods achieve much success at different levels, accurate protein model quality assessment is still an open problem. Here, we present the MQAPRank, a global protein model quality assessment program based on learning-to-rank. The MQAPRank first sorts the decoy models by using single method based on learning-to-rank algorithm to indicate their relative qualities for the target protein. And then it takes the first five models as references to predict the qualities of other models by using average GDT_TS scores between reference models and other models. Benchmarked on CASP11 and 3DRobot datasets, the MQAPRank achieved better performances than other leading protein model quality assessment methods. Recently, the MQAPRank participated in the CASP12 under the group name FDUBio and achieved the state-of-the-art performances. The MQAPRank provides a convenient and powerful tool for protein model quality assessment with the state-of-the-art performances, it is useful for protein structure prediction and model quality assessment usages.

  11. Evaluating quality in endoscopy.

    PubMed

    Pohl, Heiko

    2017-06-01

    Despite an increasing number of publications and suggested quality measures, evaluating quality in endoscopy remains a challenge. Most quality measures are process measures and lack evidence for an association with clinically important outcomes. Furthermore, most measure focus on procedural aspects. Patients' expectations, cultural values, and work setting also affect quality, but are less often considered. The aim of this article is to broaden the view on quality assessment. Here, quality is viewed from four perspectives: an individual patient perspective, which considers expectations and personal values; a cultural perspective, which encompasses cultural values and norms; an individual care perspective, which includes how an individual patient is being treated; and a societal perspective, which sets the stage for provided care. The article concludes with a proposal to consider bundled composite measures as a path to a simple yet comprehensive approach to assessing and measuring quality in endoscopy. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Adult orthodontics: a quality assessment of Internet information.

    PubMed

    McMorrow, Siobhán Mary; Millett, Declan T

    2016-09-01

    This study evaluated the quality, reliability and readability of information on the Internet on adult orthodontics. A quality assessment of adult orthodontic websites. Postgraduate Orthodontic Unit, Cork University Dental School and Hospital, Cork, Ireland. An Internet search using three search engines (Google, Yahoo and Bing) was conducted using the terms ('adult orthodontics' and 'adult braces'). The first 50 websites from each engine and under each search term were screened and exclusion criteria applied. Included websites were then assessed for quality using four methods: the HON seal, JAMA benchmarks, the DISCERN instrument and the LIDA tool. Readability of included websites was assessed using the Flesch Reading Ease Score (FRES). Only 13 websites met the inclusion criteria. Most were of US origin (n = 8; 61%). The authors of the websites were dentists (n = 5; 39%), professional organizations (n = 2; 15%), past patients (n = 2; 15%) and unspecified (n = 4; 31%). Only 1 website displayed the HON seal and three websites contained all JAMA benchmarks. The mean overall score for DISCERN was 3.9/5 and the mean total LIDA score was 115/144. The average FRES score was 63.1/100. The number of informative websites on adult orthodontics is low and these are of moderate quality. More accurate, high-quality Internet resources are required on adult orthodontics. Recommendations are made as to how this may be achieved.

  13. Michigan lakes: An assessment of water quality

    USGS Publications Warehouse

    Minnerick, R.J.

    2004-01-01

    Michigan has more than 11,000 inland lakes, that provide countless recreational opportunities and are an important resource that makes tourism and recreation a $15-billion-dollar per-year industry in the State (Stynes, 2002). Knowledge of the water-quality characteristics of inland lakes is essential for the current and future management of these resources.Historically the U. S. Geological Survey (USGS) and the Michigan Department of Environmental Quality (MDEQ) jointly have monitored water quality in Michigan's lakes and rivers. During the 1990's, however, funding for surface-water-quality monitoring was reduced greatly. In 1998, the citizens of Michigan passed the Clean Michigan Initiative to clean up, protect, and enhance Michigan's environmental infrastructure. Because of expanding water-quality-data needs, the MDEQ and the USGS jointly redesigned and implemented the Lake Water-Quality Assessment (LWQA) Monitoring Program (Michigan Department of Environmental Quality, 1997).

  14. Groundwater-quality data from the National Water-Quality Assessment Project, January through December 2014 and select quality-control data from May 2012 through December 2014

    USGS Publications Warehouse

    Arnold, Terri L.; Bexfield, Laura M.; Musgrove, MaryLynn; Lindsey, Bruce D.; Stackelberg, Paul E.; Barlow, Jeannie R.; Desimone, Leslie A.; Kulongoski, Justin T.; Kingsbury, James A.; Ayotte, Joseph D.; Fleming, Brandon J.; Belitz, Kenneth

    2017-10-05

    Groundwater-quality data were collected from 559 wells as part of the National Water-Quality Assessment Project of the U.S. Geological Survey National Water-Quality Program from January through December 2014. The data were collected from four types of well networks: principal aquifer study networks, which are used to assess the quality of groundwater used for public water supply; land-use study networks, which are used to assess land-use effects on shallow groundwater quality; major aquifer study networks, which are used to assess the quality of groundwater used for domestic supply; and enhanced trends networks, which are used to evaluate the time scales during which groundwater quality changes. Groundwater samples were analyzed for a large number of water-quality indicators and constituents, including major ions, nutrients, trace elements, volatile organic compounds, pesticides, radionuclides, and some constituents of special interest (arsenic speciation, chromium [VI] and perchlorate). These groundwater-quality data, along with data from quality-control samples, are tabulated in this report and in an associated data release.

  15. Monitoring and Assessment of Youshui River Water Quality in Youyang

    NASA Astrophysics Data System (ADS)

    Wang, Xue-qin; Wen, Juan; Chen, Ping-hua; Liu, Na-na

    2018-02-01

    By monitoring the water quality of Youshui River from January 2016 to December 2016, according to the indicator grading and the assessment standard of water quality, the formulas for 3 types water quality indexes are established. These 3 types water quality indexes, the single indicator index Ai, single moment index Ak and the comprehensive water quality index A, were used to quantitatively evaluate the quality of single indicator, the water quality and the change of water quality with time. The results show that, both total phosphorus and fecal coliform indicators exceeded the standard, while the other 16 indicators measured up to the standard. The water quality index of Youshui River is 0.93 and the grade of water quality comprehensive assessment is level 2, which indicated that the water quality of Youshui River is good, and there is room for further improvement. To this end, several protection measures for Youshui River environmental management and pollution treatment are proposed.

  16. Assessing Quality in Graduate Programs: An Internal Quality Indicator. AIR Forum 1981 Paper.

    ERIC Educational Resources Information Center

    DiBiasio, Daniel A.; And Others

    Four approaches to measuring quality in graduate education are reviewed, and the approach used at the graduate school at Ohio State University is assessed. Four approaches found in the literature are: measuring quality by reputation, by scholarly productivity, by correlating reputation and scholarly productivity, and by multiple measures. Ohio…

  17. Display device-adapted video quality-of-experience assessment

    NASA Astrophysics Data System (ADS)

    Rehman, Abdul; Zeng, Kai; Wang, Zhou

    2015-03-01

    Today's viewers consume video content from a variety of connected devices, including smart phones, tablets, notebooks, TVs, and PCs. This imposes significant challenges for managing video traffic efficiently to ensure an acceptable quality-of-experience (QoE) for the end users as the perceptual quality of video content strongly depends on the properties of the display device and the viewing conditions. State-of-the-art full-reference objective video quality assessment algorithms do not take into account the combined impact of display device properties, viewing conditions, and video resolution while performing video quality assessment. We performed a subjective study in order to understand the impact of aforementioned factors on perceptual video QoE. We also propose a full reference video QoE measure, named SSIMplus, that provides real-time prediction of the perceptual quality of a video based on human visual system behaviors, video content characteristics (such as spatial and temporal complexity, and video resolution), display device properties (such as screen size, resolution, and brightness), and viewing conditions (such as viewing distance and angle). Experimental results have shown that the proposed algorithm outperforms state-of-the-art video quality measures in terms of accuracy and speed.

  18. Prioritizing quality improvement in general surgery.

    PubMed

    Schilling, Peter L; Dimick, Justin B; Birkmeyer, John D

    2008-11-01

    Despite growing interest in quality improvement, uncertainty remains about which procedures offer the most room for improvement in general surgery. In this context, we sought to describe the relative contribution of different procedures to overall morbidity, mortality, and excess length of stay in general surgery. Using data from the American College of Surgeons' National Surgery Quality Improvement Program (ACS-NSQIP), we identified all patients undergoing a general surgery procedure in 2005 and 2006 (n=129,233). Patients were placed in 36 distinct procedure groups based on Current Procedural Terminology codes. We first examined procedure groups according to their relative contribution to overall morbidity and mortality. We then assessed procedure groups according to their contribution to overall excess length of stay. Ten procedure groups alone accounted for 62% of complications and 54% of excess hospital days. Colectomy accounted for the greatest share of adverse events, followed by small intestine resection, inpatient cholecystectomy, and ventral hernia repair. In contrast, several common procedures contributed little to overall morbidity and mortality. For example, outpatient cholecystectomy, breast procedures, thyroidectomy, parathyroidectomy, and outpatient inguinal hernia repair together accounted for 34% of procedures, but only 6% of complications (and only 4% of major complications). These same procedures accounted for < 1% of excess hospital days. A relatively small number of procedures account for a disproportionate share of the morbidity, mortality, and excess hospital days in general surgery. Focusing quality improvement efforts on these procedures may be an effective strategy for improving patient care and reducing cost.

  19. A Procedural Skills OSCE: Assessing Technical and Non-Technical Skills of Internal Medicine Residents

    ERIC Educational Resources Information Center

    Pugh, Debra; Hamstra, Stanley J.; Wood, Timothy J.; Humphrey-Murto, Susan; Touchie, Claire; Yudkowsky, Rachel; Bordage, Georges

    2015-01-01

    Internists are required to perform a number of procedures that require mastery of technical and non-technical skills, however, formal assessment of these skills is often lacking. The purpose of this study was to develop, implement, and gather validity evidence for a procedural skills objective structured clinical examination (PS-OSCE) for internal…

  20. [Process-oriented quality management in the hospital].

    PubMed

    Wolters, H G

    1998-03-01

    Procedures and experiences concerning the implementation of quality management in a midsize hospital with 6 medical disciplines are described. Quality of infrastructure was checked with lists and the quality of medical performance assessed by means of standardized numerical audit with all professional groups. Weaknesses were identified by comparing the result to each quality indicator with target standards. As examples, causal relations and consequences of deficiencies in clinical care documentation, scheme of preoperative diagnosis, co-ordination of surgical procedures and handling of complications are given in more detail. Obstacles were rated depending on frequency and risk potential, sometimes cost effectiveness. Members of all professional groups and departments involved participated in trouble solving teams to which external expert assistance was provided. For example, interventions leading to improved co-ordination of surgical activities and their impacts are specified. Improving systematically the quality of clinical procedures is one gateway to establish quality management in hospitals continuously and thoroughly becoming an integrated part of the corporate culture. Investment of resources is necessary but justified by midrange benefits.

  1. Quality Management Plan for the Environmental Assessment and Innovation Division

    EPA Pesticide Factsheets

    Quality management plan (QMP) which identifies the mission, roles, responsibilities of personnel with regard to quality assurance and quality management for the environmental assessment and innovation division.

  2. Low-cost oblique illumination: an image quality assessment.

    PubMed

    Ruiz-Santaquiteria, Jesus; Espinosa-Aranda, Jose Luis; Deniz, Oscar; Sanchez, Carlos; Borrego-Ramos, Maria; Blanco, Saul; Cristobal, Gabriel; Bueno, Gloria

    2018-01-01

    We study the effectiveness of several low-cost oblique illumination filters to improve overall image quality, in comparison with standard bright field imaging. For this purpose, a dataset composed of 3360 diatom images belonging to 21 taxa was acquired. Subjective and objective image quality assessments were done. The subjective evaluation was performed by a group of diatom experts by psychophysical test where resolution, focus, and contrast were assessed. Moreover, some objective nonreference image quality metrics were applied to the same image dataset to complete the study, together with the calculation of several texture features to analyze the effect of these filters in terms of textural properties. Both image quality evaluation methods, subjective and objective, showed better results for images acquired using these illumination filters in comparison with the no filtered image. These promising results confirm that this kind of illumination filters can be a practical way to improve the image quality, thanks to the simple and low cost of the design and manufacturing process. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  3. [Ecological environmental quality assessment of Hangzhou urban area based on RS and GIS].

    PubMed

    Xu, Pengwei; Zhao, Duo

    2006-06-01

    In allusion to the shortage of traditional ecological environmental quality assessment, this paper studied the spatial distribution of assessing factors at a mid-small scale, and the conversion of integer character to girding assessing cells. The main assessing factors including natural environmental condition, environmental quality, natural landscape and urbanization pressure, which were classified into four types with about eleven assessing factors, were selected from RS images and GIS-spatial analyzing environmental quality vector graph. Based on GIS, a comprehensive assessment model for the ecological environmental quality in Hangzhou urban area was established. In comparison with observed urban heat island effects, the assessment results were in good agreement with the ecological environmental quality in the urban area of Hangzhou.

  4. 42 CFR 438.240 - Quality assessment and performance improvement program.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 4 2011-10-01 2011-10-01 false Quality assessment and performance improvement program. 438.240 Section 438.240 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL ASSISTANCE PROGRAMS MANAGED CARE Quality Assessment and...

  5. 42 CFR 438.240 - Quality assessment and performance improvement program.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 4 2013-10-01 2013-10-01 false Quality assessment and performance improvement program. 438.240 Section 438.240 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL ASSISTANCE PROGRAMS MANAGED CARE Quality Assessment and...

  6. 42 CFR 438.240 - Quality assessment and performance improvement program.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 4 2012-10-01 2012-10-01 false Quality assessment and performance improvement program. 438.240 Section 438.240 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL ASSISTANCE PROGRAMS MANAGED CARE Quality Assessment and...

  7. 42 CFR 438.240 - Quality assessment and performance improvement program.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 4 2014-10-01 2014-10-01 false Quality assessment and performance improvement program. 438.240 Section 438.240 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL ASSISTANCE PROGRAMS MANAGED CARE Quality Assessment and...

  8. Drinking Water Quality Assessment Studies for an Urbanized Part of the Nagpur District, Central India.

    PubMed

    Varade, Abhay M; Yenkie, Rajshree; Shende, Rahul; Kodate, Jaya

    2014-01-01

    The water quality of Hingna area of Nagpur district, Central India was assessed for its suitability as drinking water. 22 water samples, representing both the surface and groundwater sources, were collected and analysed for different inorganic constituents by using the standard procedures. The result depicted abundance of major ions; Ca2+ > Mg2+ > Na+ > K+ = HCO3- > Cl- > SO4(2-) > NO3-. The concentrations of different elements in water were compared with the drinking water standards defined by World Health Organization (WHO). The hydro-chemical results reveal that most of the samples were within the desirable limits of the drinking water quality. However, few samples of the area, showed higher values of total dissolved solids (TDS), total hardness (TH), and magnesium (Mg) indicating their 'hard water type' nature and found to be unfit for the drinking purpose. Such poor water quality of these samples is found due to the combined effect of urbanization and industrial activities. The potential health risks associated with various water parameters have also been documented in this paper.

  9. Image quality assessment by preprocessing and full reference model combination

    NASA Astrophysics Data System (ADS)

    Bianco, S.; Ciocca, G.; Marini, F.; Schettini, R.

    2009-01-01

    This paper focuses on full-reference image quality assessment and presents different computational strategies aimed to improve the robustness and accuracy of some well known and widely used state of the art models, namely the Structural Similarity approach (SSIM) by Wang and Bovik and the S-CIELAB spatial-color model by Zhang and Wandell. We investigate the hypothesis that combining error images with a visual attention model could allow a better fit of the psycho-visual data of the LIVE Image Quality assessment Database Release 2. We show that the proposed quality assessment metric better correlates with the experimental data.

  10. Factors Influencing Assessment Quality in Higher Vocational Education

    ERIC Educational Resources Information Center

    Baartman, Liesbeth; Gulikers, Judith; Dijkstra, Asha

    2013-01-01

    The development of assessments that are fit to assess professional competence in higher vocational education requires a reconsideration of assessment methods, quality criteria and (self)evaluation. This article examines the self-evaluations of nine courses of a large higher vocational education institute. Per course, 4-11 teachers and 3-10…

  11. Guidance Program Assessment Procedures for Elementary and Secondary Schools. Georgia Comprehensive Guidance Series.

    ERIC Educational Resources Information Center

    Gunderson, Margaret S.; Moore, Earl J.

    This manual provides a series of assessment instruments that guidance program planners may adopt or adapt to provide a basis for defining the guidance program, educating others about the program, or planning needed program changes. The assessment procedures are designed to gather information about students' needs and progress from the students,…

  12. Vibration Testing Procedures for Bone Stiffness Assessment in Fractures Treated with External Fixation.

    PubMed

    Mattei, Lorenza; Longo, Antonia; Di Puccio, Francesca; Ciulli, Enrico; Marchetti, Stefano

    2017-04-01

    A bone healing assessment is crucial for the successful treatment of fractures, particularly in terms of the timing of support devices. However, in clinical practice, this assessment is only made qualitatively through bone manipulation and X-rays, and hence cannot be repeated as often as might be required. The present study reconsiders the quantitative method of frequency response analysis for healing assessments, and specifically for fractures treated with an external fixator. The novelty consists in the fact that bone excitation and response are achieved through fixator pins, thus overcoming the problem of transmission through soft-tissues and their damping effect. The main objective was to develop and validate a test procedure in order to characterize the treated bone. More than 80 tests were performed on a tibia phantom alone, a phantom with pins, and a phantom with a complete fixator. Different excitation techniques and input-output combinations were compared. The results demonstrated the effectiveness of a procedure based on impact tests using a micro-hammer. Pins and fixator were demonstrated to influence the frequency response of the phantom by increasing the number of resonant frequencies. This procedure will be applied in future studies to monitor healing both in in vitro and in vivo conditions.

  13. Retinal image quality assessment based on image clarity and content

    NASA Astrophysics Data System (ADS)

    Abdel-Hamid, Lamiaa; El-Rafei, Ahmed; El-Ramly, Salwa; Michelson, Georg; Hornegger, Joachim

    2016-09-01

    Retinal image quality assessment (RIQA) is an essential step in automated screening systems to avoid misdiagnosis caused by processing poor quality retinal images. A no-reference transform-based RIQA algorithm is introduced that assesses images based on five clarity and content quality issues: sharpness, illumination, homogeneity, field definition, and content. Transform-based RIQA algorithms have the advantage of considering retinal structures while being computationally inexpensive. Wavelet-based features are proposed to evaluate the sharpness and overall illumination of the images. A retinal saturation channel is designed and used along with wavelet-based features for homogeneity assessment. The presented sharpness and illumination features are utilized to assure adequate field definition, whereas color information is used to exclude nonretinal images. Several publicly available datasets of varying quality grades are utilized to evaluate the feature sets resulting in area under the receiver operating characteristic curve above 0.99 for each of the individual feature sets. The overall quality is assessed by a classifier that uses the collective features as an input vector. The classification results show superior performance of the algorithm in comparison to other methods from literature. Moreover, the algorithm addresses efficiently and comprehensively various quality issues and is suitable for automatic screening systems.

  14. External quality assessment unravels interlaboratory differences in quality of RAS testing for anti-EGFR therapy in colorectal cancer.

    PubMed

    Tack, Véronique; Ligtenberg, Marjolijn J L; Tembuyser, Lien; Normanno, Nicola; Vander Borght, Sara; Han van Krieken, J; Dequeker, Elisabeth M C

    2015-03-01

    Regulations for the selection of patients with metastatic colorectal cancer for anti-EGFR treatment changed at the end of 2013. The set of mutations to be tested extended from KRAS codons 12 and 13 to KRAS and NRAS exons 2, 3, and 4. A European external quality assessment scheme monitored the performance of laboratories and evaluated the implementation of the new regulations. The 131 participating laboratories received 10 samples of formalin-fixed paraffin-embedded material, including RAS (exon 2, 3, 4) and BRAF mutations. Mock clinical data were provided for three cases. Using their routine methods, laboratories determined the genotypes and submitted three written reports. Assessors scored the results according to predefined evaluation criteria. Half of the participants (49.3%) had completely implemented the new test requirements (codons 12, 13, 59, 61, 117, and 146 of KRAS and NRAS), and 96 laboratories (73.3%) made no genotype mistakes. Correct nomenclature, according to the Human Genome Variation Society, was used by 82 laboratories (62.6%). Although regulations were effective for several months, many laboratories were not ready for full RAS testing in the context of anti-EGFR therapy. Nevertheless, in each participating country, there are laboratories that provide complete and correct testing. External quality assessments can be used to monitor implementation of new test regulations and to stimulate the laboratories to improve their testing procedures. Because the results of this program are available on the website of the European Society of Pathology, patients and clinicians can refer test samples to a reliable laboratory. ©AlphaMed Press.

  15. Functional Behavioral Assessment State Policies and Procedures. Quick Turn Around (QTA).

    ERIC Educational Resources Information Center

    National Association of State Directors of Special Education, Alexandria, VA.

    This brief report provides an analysis of survey data collected from 45 states and territories about policies, procedures, and guidelines related to Functional Behavioral Assessment (FBA), plans to develop or revise policy in this area, and technical assistance needs related to FBA, especially for students who exhibit behavior that interferes with…

  16. 42 CFR 438.240 - Quality assessment and performance improvement program.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Quality assessment and performance improvement... Performance Improvement Measurement and Improvement Standards § 438.240 Quality assessment and performance improvement program. (a) General rules. (1) The State must require, through its contracts, that each MCO and...

  17. Quality Procedures in the European Higher Education Area and Beyond--Visions for the Future: Third ENQA Survey. ENQA Occasional Papers 18

    ERIC Educational Resources Information Center

    Grifoll, Josep; Hopbach, Achim; Kekalainen, Helka; Lugano, Nathalie; Rozsnyai, Christina; Shopov, Todor

    2012-01-01

    Higher education reforms over the last decade, resulting in the establishment of the European Higher Education Area, with new social demands and expectations, have greatly impacted quality assurance in higher education. As a follow-up activity to two previous surveys on external quality procedures, the European Association for Quality Assurance in…

  18. Objective quality assessment for multiexposure multifocus image fusion.

    PubMed

    Hassen, Rania; Wang, Zhou; Salama, Magdy M A

    2015-09-01

    There has been a growing interest in image fusion technologies, but how to objectively evaluate the quality of fused images has not been fully understood. Here, we propose a method for objective quality assessment of multiexposure multifocus image fusion based on the evaluation of three key factors of fused image quality: 1) contrast preservation; 2) sharpness; and 3) structure preservation. Subjective experiments are conducted to create an image fusion database, based on which, performance evaluation shows that the proposed fusion quality index correlates well with subjective scores, and gives a significant improvement over the existing fusion quality measures.

  19. A Quality Approach to Writing Assessment.

    ERIC Educational Resources Information Center

    Andrade, Joanne; Ryley, Helen

    1992-01-01

    A Colorado elementary school began its Total Quality Management work about a year ago after several staff members participated in an IBM Leadership Training Program addressing applications of Deming's theories. The school's new writing assessment has increased collegiality and cross-grade collaboration. (MLH)

  20. NASA Safety Standard: Guidelines and Assessment Procedures for Limiting Orbital Debris

    NASA Technical Reports Server (NTRS)

    1995-01-01

    Collision with orbital debris is a hazard of growing concern as historically accepted practices and procedures have allowed man-made objects to accumulate in orbit. To limit future debris generation, NASA Management Instruction (NMI) 1700.8, 'Policy to Limit Orbital Debris Generation,' was issued in April of 1993. The NMI requires each program to conduct a formal assessment of the potential to generate orbital debris. This document serves as a companion to NMI 1700.08 and provides each NASA program with specific guidelines and assessment methods to assure compliance with the NMI. Each main debris assessment issue (e.g., Post Mission Disposal) is developed in a separate chapter.

  1. Assessing the Methodological Quality of Glaucoma Clinical Practice Guidelines and Their Recommendations on Microinvasive Glaucoma Surgery: A Systematic Review.

    PubMed

    Michaelov, Evan; Armstrong, James J; Nguyen, Mary; Instrum, Bridget; Lam, Tracey; Denstedt, James; Hutnik, Cindy M L

    2018-02-01

    Clinical practice guidelines (CPG) are regarded by many as critical communications providing guidance within specific medical fields. Over a decade ago, the first microinvasive glaucoma surgical (MIGS) procedures were introduced. Since then, a number of these novel intraocular pressure controlling surgical options have been approved worldwide. Governing bodies and health care administration often utilize CPGs when considering funding for newer technologies. This highlights the importance of well-written, accurate, and up-to-date CPGs in the rapidly evolving field of MIGS. If CPGs are unable to fill this role, their use in treatment decision-making is doing a disservice to patients, who will be denied currently available and potentially superior care. To determine the overall value of a CPG, the methodological quality with which it was developed, in addition to the current relevance and appropriateness of its recommendations, should be evaluated. The objective of the present study was to assess the methodological quality of currently available international glaucoma CPGs, as well as their coverage of MIGS as a surrogate marker of relevance and appropriateness to policy-makers and ophthalmologists alike. To identify potentially relevant CPGs, a predefined search strategy was used to search the following databases: Medline, EMBASE, BIOSIS, and Web of Science. All CPGs related to adult glaucoma and published in English were included. CPG methodological quality was assessed by 3 individuals using the Appraisal of Guidelines for Research and Evaluation II (AGREE II) tool. Studies were then assessed for coverage of MIGS devices and procedures. Search strategy and subsequent screening identified 11 CPGs for analysis. Eight were of high quality according to the AGREE II criteria. Three included basic information on MIGS, but none provided specific recommendations regarding their indications or which patient populations would benefit most. Many international glaucoma CPGs

  2. Using an Android application to assess registration strategies in open hepatic procedures: a planning and simulation tool

    NASA Astrophysics Data System (ADS)

    Doss, Derek J.; Heiselman, Jon S.; Collins, Jarrod A.; Weis, Jared A.; Clements, Logan W.; Geevarghese, Sunil K.; Miga, Michael I.

    2017-03-01

    Sparse surface digitization with an optically tracked stylus for use in an organ surface-based image-to-physical registration is an established approach for image-guided open liver surgery procedures. However, variability in sparse data collections during open hepatic procedures can produce disparity in registration alignments. In part, this variability arises from inconsistencies with the patterns and fidelity of collected intraoperative data. The liver lacks distinct landmarks and experiences considerable soft tissue deformation. Furthermore, data coverage of the organ is often incomplete or unevenly distributed. While more robust feature-based registration methodologies have been developed for image-guided liver surgery, it is still unclear how variation in sparse intraoperative data affects registration. In this work, we have developed an application to allow surgeons to study the performance of surface digitization patterns on registration. Given the intrinsic nature of soft-tissue, we incorporate realistic organ deformation when assessing fidelity of a rigid registration methodology. We report the construction of our application and preliminary registration results using four participants. Our preliminary results indicate that registration quality improves as users acquire more experience selecting patterns of sparse intraoperative surface data.

  3. Standard operating procedures improve acute neurologic care in a sub-Saharan African setting

    PubMed Central

    Jaiteh, Lamin E.S.; Helwig, Stefan A.; Jagne, Abubacarr; Ragoschke-Schumm, Andreas; Sarr, Catherine; Walter, Silke; Lesmeister, Martin; Manitz, Matthias; Blaß, Sebastian; Weis, Sarah; Schlund, Verena; Bah, Neneh; Kauffmann, Jil; Fousse, Mathias; Kangankan, Sabina; Ramos Cabrera, Asmell; Kronfeld, Kai; Ruckes, Christian; Liu, Yang; Nyan, Ousman

    2017-01-01

    Objective: Quality of neurologic emergency management in an under-resourced country may be improved by standard operating procedures (SOPs). Methods: Neurologic SOPs were implemented in a large urban (Banjul) and a small rural (Brikama) hospital in the Gambia. As quality indicators of neurologic emergency management, performance of key procedures was assessed at baseline and in the first and second implementation years. Results: At Banjul, 100 patients of the first-year intervention group exhibited higher rates of general procedures of emergency management than 105 control patients, such as neurologic examination (99.0% vs 91.4%; p < 0.05) and assessments of respiratory rate (98.0% vs 81.9%, p < 0.001), temperature (60.0% vs 36.2%; p < 0.001), and glucose levels (73.0% vs 58.1%; p < 0.05), in addition to written directives by physicians (96.0% vs 88.6%, p < 0.05), whereas assessments of other vital signs remained unchanged. In stroke patients, rates of stroke-related procedures increased: early CT scanning (24.3% vs 9.9%; p < 0.05), blood count (73.0% vs 49.3%; p < 0.01), renal and liver function tests (50.0% vs 5.6%, p < 0.001), aspirin prophylaxis (47.3% vs 9.9%; p < 0.001), and physiotherapy (41.9% vs 4.2%; p < 0.001). Most effects persisted until the second-year evaluation. SOP implementation was similarly feasible and beneficial at the Brikama hospital. However, outcomes did not significantly differ in the hospitals. Conclusions: Implementing SOPs is a realistic, low-cost option for improving process quality of neurologic emergency management in under-resourced settings. Classification of evidence: This study provides Class IV evidence that, for patients with suspected neurologic emergencies in sub-Saharan Africa, neurologic SOPs increase the rate of performance of guideline-recommended procedures. PMID:28600460

  4. Standard operating procedures improve acute neurologic care in a sub-Saharan African setting.

    PubMed

    Jaiteh, Lamin E S; Helwig, Stefan A; Jagne, Abubacarr; Ragoschke-Schumm, Andreas; Sarr, Catherine; Walter, Silke; Lesmeister, Martin; Manitz, Matthias; Blaß, Sebastian; Weis, Sarah; Schlund, Verena; Bah, Neneh; Kauffmann, Jil; Fousse, Mathias; Kangankan, Sabina; Ramos Cabrera, Asmell; Kronfeld, Kai; Ruckes, Christian; Liu, Yang; Nyan, Ousman; Fassbender, Klaus

    2017-07-11

    Quality of neurologic emergency management in an under-resourced country may be improved by standard operating procedures (SOPs). Neurologic SOPs were implemented in a large urban (Banjul) and a small rural (Brikama) hospital in the Gambia. As quality indicators of neurologic emergency management, performance of key procedures was assessed at baseline and in the first and second implementation years. At Banjul, 100 patients of the first-year intervention group exhibited higher rates of general procedures of emergency management than 105 control patients, such as neurologic examination (99.0% vs 91.4%; p < 0.05) and assessments of respiratory rate (98.0% vs 81.9%, p < 0.001), temperature (60.0% vs 36.2%; p < 0.001), and glucose levels (73.0% vs 58.1%; p < 0.05), in addition to written directives by physicians (96.0% vs 88.6%, p < 0.05), whereas assessments of other vital signs remained unchanged. In stroke patients, rates of stroke-related procedures increased: early CT scanning (24.3% vs 9.9%; p < 0.05), blood count (73.0% vs 49.3%; p < 0.01), renal and liver function tests (50.0% vs 5.6%, p < 0.001), aspirin prophylaxis (47.3% vs 9.9%; p < 0.001), and physiotherapy (41.9% vs 4.2%; p < 0.001). Most effects persisted until the second-year evaluation. SOP implementation was similarly feasible and beneficial at the Brikama hospital. However, outcomes did not significantly differ in the hospitals. Implementing SOPs is a realistic, low-cost option for improving process quality of neurologic emergency management in under-resourced settings. This study provides Class IV evidence that, for patients with suspected neurologic emergencies in sub-Saharan Africa, neurologic SOPs increase the rate of performance of guideline-recommended procedures. Copyright © 2017 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Neurology.

  5. [External quality assurance in inpatient medical rehabilitation and prevention centers for mothers, fathers and children: development of instruments for assessing structural quality].

    PubMed

    Saupe-Heide, M; Gerlich, C; Lukasczik, M; Musekamp, G; Neuderth, S; Vogel, H

    2013-12-01

    As required by German law, inpatient institutions offering prevention and rehabilitation measures for mothers, fathers and children are obliged to implement external quality assurance measures. In 2 pilot projects funded by the German federal association of health insurance funds, external quality assurance procedures for in-hospital prevention and rehabilitation of mothers and fathers were analyzed with the aim of developing a set of instruments for the description of structural characteristics in this area of health care and to evaluate its appropriateness. Concerning structure-related quality, the project included a) designing and evaluating a questionnaire, b) the definition of assessment criteria for subsequent comparative data analyses, and c) the description and documentation of the current state in the field of rehabilitation and prevention for mothers, fathers and children. To document structural quality comprehensively, a modular questionnaire was developed and tested in a survey of 115 inpatient prevention and rehabilitation institutions for mothers, fathers and children. Involving an expert panel, preliminary basic and selection criteria were defined in order to assure a conducive assessment with regard to structural attributes. The majority of institutions had provider agreements for both prevention and rehabilitation. Measures for mothers/fathers with children were predominant; only 7 institutions exclusively treated mothers and fathers. Institution sizes varied strongly. Major indications included psychosomatics, dermatology, and pneumology. Overall, structural conditions of the institutions showed a high standard. Potential for development was found with regard to some aspects of the conceptual framework of institutional practice and the implementation of the International Classification of Functioning, Disability and Health (ICF) in diagnostics. In this article, the degrees of fulfillment with relation to the structural dimensions are presented

  6. 40 CFR 1515.1 - FOIA procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Protection of Environment COUNCIL ON ENVIRONMENTAL QUALITY FREEDOM OF INFORMATION ACT PROCEDURES Purpose § 1515.1 FOIA procedures. The Freedom of Information Act (5 U.S.C. 552), as amended, commonly known as... Section 552(b) of the Act. These procedures explain how the Council on Environmental Quality (CEQ)—one of...

  7. 40 CFR 1515.1 - FOIA procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Protection of Environment COUNCIL ON ENVIRONMENTAL QUALITY FREEDOM OF INFORMATION ACT PROCEDURES Purpose § 1515.1 FOIA procedures. The Freedom of Information Act (5 U.S.C. 552), as amended, commonly known as... Section 552(b) of the Act. These procedures explain how the Council on Environmental Quality (CEQ)—one of...

  8. 40 CFR 1515.1 - FOIA procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Protection of Environment COUNCIL ON ENVIRONMENTAL QUALITY FREEDOM OF INFORMATION ACT PROCEDURES Purpose § 1515.1 FOIA procedures. The Freedom of Information Act (5 U.S.C. 552), as amended, commonly known as... Section 552(b) of the Act. These procedures explain how the Council on Environmental Quality (CEQ)—one of...

  9. 40 CFR 1515.1 - FOIA procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Protection of Environment COUNCIL ON ENVIRONMENTAL QUALITY FREEDOM OF INFORMATION ACT PROCEDURES Purpose § 1515.1 FOIA procedures. The Freedom of Information Act (5 U.S.C. 552), as amended, commonly known as... Section 552(b) of the Act. These procedures explain how the Council on Environmental Quality (CEQ)—one of...

  10. Assessing the Quality of PhD Dissertations. A Survey of External Committee Members

    ERIC Educational Resources Information Center

    Kyvik, Svein; Thune, Taran

    2015-01-01

    This article reports on a study of the quality assessment of doctoral dissertations, and asks whether examiner characteristics influence assessment of research quality in PhD dissertations. Utilising a multi-dimensional concept of quality of PhD dissertations, we look at differences in assessment of research quality, and particularly test whether…

  11. Synthesized view comparison method for no-reference 3D image quality assessment

    NASA Astrophysics Data System (ADS)

    Luo, Fangzhou; Lin, Chaoyi; Gu, Xiaodong; Ma, Xiaojun

    2018-04-01

    We develop a no-reference image quality assessment metric to evaluate the quality of synthesized view rendered from the Multi-view Video plus Depth (MVD) format. Our metric is named Synthesized View Comparison (SVC), which is designed for real-time quality monitoring at the receiver side in a 3D-TV system. The metric utilizes the virtual views in the middle which are warped from left and right views by Depth-image-based rendering algorithm (DIBR), and compares the difference between the virtual views rendered from different cameras by Structural SIMilarity (SSIM), a popular 2D full-reference image quality assessment metric. The experimental results indicate that our no-reference quality assessment metric for the synthesized images has competitive prediction performance compared with some classic full-reference image quality assessment metrics.

  12. Educational Quality, Outcomes Assessment, and Policy Change: The Virginia Example

    ERIC Educational Resources Information Center

    Culver, Steve

    2010-01-01

    The higher education system in the Commonwealth of Virginia in the United States provides a case model for how discussions regarding educational quality and assessment of that quality have affected institutions' policy decisions and implementation. Using Levin's (1998) policy analysis framework, this essay explores how assessment of student…

  13. Water-quality data-collection activities in Colorado and Ohio; Phase III, evaluation of existing data for use in assessing regional water-quality conditions and trends

    USGS Publications Warehouse

    Norris, J. Michael; Hren, Janet; Myers, Donna N.; Chaney, Thomas H.; Childress, Carolyn J. Oblinger

    1990-01-01

    During the past several years, a growing number of questions have been raised by members of Congress and others about the status of current waterquality conditions in the Nation, trends in water quality, and the major factors that affect water-quality conditions and trends. One area of particular interest and concern has been the suitability of existing water-quality data for addressing these types of questions at regional and national scales. In response to these questions and concerns, the U.S. Geological Survey began a pilot study in Colorado and Ohio to (1) determine the characteristics of current water-quality data-collection activities of Federal, State, regional, and local agencies and universities; and (2) determine how well the data from these activities, collected for various purposes and using different procedures, can be used to improve our ability to address the aforementioned questions.Colorado and Ohio were chosen for the pilot study because they represent regions with different types of water-quality issues and programs. The results of the study are specific to the two States and are not intended to be extrapolated to other States.The study was divided into three phases whose objectives were:Phase I Identify and inventory 1984 water-quality data-collection programs, including costs, in Colorado and Ohio, and identify those programs that meet a set of broad criteria for producing data that potentially are appropriate for water-quality assessments of regional and national scope. Phase II Evaluate the quality assurance of field and laboratory procedures used to produce the data from programs that met the broad criteria of Phase I. Phase III Compile the qualifying data from Phase II and evaluate the extent to which the resulting data base can be used to address selected water-quality questions for the two States.This report presents the results of Phase III, focusing on (1) the number of measurements made at each data-collection site for selected

  14. Indoor Air Quality Building Education and Assessment Model Forms

    EPA Pesticide Factsheets

    The Indoor Air Quality Building Education and Assessment Model (I-BEAM) is a guidance tool designed for use by building professionals and others interested in indoor air quality in commercial buildings.

  15. Head-camera video recordings of trauma core competency procedures can evaluate surgical resident's technical performance as well as colocated evaluators.

    PubMed

    Mackenzie, Colin F; Pasley, Jason; Garofalo, Evan; Shackelford, Stacy; Chen, Hegang; Longinaker, Nyaradzo; Granite, Guinevere; Pugh, Kristy; Hagegeorge, George; Tisherman, Samuel A

    2017-07-01

    Unbiased evaluation of trauma core competency procedures is necessary to determine if residency and predeployment training courses are useful. We tested whether a previously validated individual procedure score (IPS) for individual procedure vascular exposure and fasciotomy (FAS) performance skills could discriminate training status by comparing IPS of evaluators colocated with surgeons to blind video evaluations. Performance of axillary artery (AA), brachial artery (BA), and femoral artery (FA) vascular exposures and lower extremity FAS on fresh cadavers by 40 PGY-2 to PGY-6 residents was video-recorded from head-mounted cameras. Two colocated trained evaluators assessed IPS before and after training. One surgeon in each pretraining tertile of IPS for each procedure was randomly identified for blind video review. The same 12 surgeons were video-recorded repeating the procedures less than 4 weeks after training. Five evaluators independently reviewed all 96 randomly arranged deidentified videos. Inter-rater reliability/consistency, intraclass correlation coefficients were compared by colocated versus video review of IPS, and errors. Study methodology and bias were judged by Medical Education Research Study Quality Instrument and the Quality Assessment of Diagnostic Accuracy Studies criteria. There were no differences (p ≥ 0.5) in IPS for AA, FA, FAS, whether evaluators were colocated or reviewed video recordings. Evaluator consistency was 0.29 (BA) - 0.77 (FA). Video and colocated evaluators were in total agreement (p = 1.0) for error recognition. Intraclass correlation coefficient was 0.73 to 0.92, dependent on procedure. Correlations video versus colocated evaluations were 0.5 to 0.9. Except for BA, blinded video evaluators discriminated (p < 0.002) whether procedures were performed before training versus after training. Study methodology by Medical Education Research Study Quality Instrument criteria scored 15.5/19, Quality Assessment of Diagnostic Accuracy

  16. Review of systematic reviews on acute procedural pain in children in the hospital setting

    PubMed Central

    Stinson, Jennifer; Yamada, Janet; Dickson, Alison; Lamba, Jasmine; Stevens, Bonnie

    2008-01-01

    BACKGROUND: Acute pain is a common experience for hospitalized children. Despite mounting research on treatments for acute procedure-related pain, it remains inadequately treated. OBJECTIVE: To critically appraise all systematic reviews on the effectiveness of acute procedure-related pain management in hospitalized children. METHODS: Published systematic reviews and meta-analyses on pharmacological and nonpharmacological management of acute procedure-related pain in hospitalized children aged one to 18 years were evaluated. Electronic searches were conducted in the Cochrane Database of Systematic Reviews, Medline, EMBASE, the Cumulative Index to Nursing and Allied Health Literature and PsycINFO. Two reviewers independently selected articles for review and assessed their quality using a validated seven-point quality assessment measure. Any disagreements were resolved by a third reviewer. RESULTS: Of 1469 published articles on interventions for acute pain in hospitalized children, eight systematic reviews met the inclusion criteria and were included in the analysis. However, only five of these reviews were of high quality. Critical appraisal of pharmacological pain interventions indicated that amethocaine was superior to EMLA (AstraZeneca Canada Inc) for reducing needle pain. Distraction and hypnosis were nonpharmacological interventions effective for management of acute procedure-related pain in hospitalized children. CONCLUSIONS: There is growing evidence of rigorous evaluations of both pharmacological and nonpharmacological strategies for acute procedure-related pain in children; however, the evidence underlying some commonly used strategies is limited. The present review will enable the creation of a future research plan to facilitate clinical decision making and to develop clinical policy for managing acute procedure-related pain in children. PMID:18301816

  17. Quality assessment of groundwater from the south-eastern Arabian Peninsula.

    PubMed

    Zhang, H W; Sun, Y Q; Li, Y; Zhou, X D; Tang, X Z; Yi, P; Murad, A; Hussein, S; Alshamsi, D; Aldahan, A; Yu, Z B; Chen, X G; Mugwaneza, V D P

    2017-08-01

    Assessment of groundwater quality plays a significant role in the utilization of the scarce water resources globally and especially in arid regions. The increasing abstraction together with man-made contamination and seawater intrusion have strongly affected groundwater quality in the Arabia Peninsula, exemplified by the investigation given here from the United Arab Emirates, where the groundwater is seldom reviewed and assessed. In the aim of assessing current groundwater quality, we here present a comparison of chemical data linked to aquifers types. The results reveal that most of the investigated groundwater is not suitable for drinking, household, and agricultural purposes following the WHO permissible limits. Aquifer composition and climate have vital control on the water quality, with the carbonate aquifers contain the least potable water compared to the ophiolites and Quaternary clastics. Seawater intrusion along coastal regions has deteriorated the water quality and the phenomenon may become more intensive with future warming climate and rising sea level.

  18. Operational Procedures for Collecting Water-Quality Samples at Monitoring Sites on Maple Creek Near Nickerson and the Platte River at Louisville, Eastern Nebraska

    USGS Publications Warehouse

    Johnson, Steven M.; Swanson, Robert B.

    1994-01-01

    Prototype stream-monitoring sites were operated during part of 1992 in the Central Nebraska Basins (CNBR) and three other study areas of the National Water-Quality Assessment (NAWQ) Program of the U.S. Geological Survey. Results from the prototype project provide information needed to operate a net- work of intensive fixed station stream-monitoring sites. This report evaluates operating procedures for two NAWQA prototype sites at Maple Creek near Nickerson and the Platte River at Louisville, eastern Nebraska. Each site was sampled intensively in the spring and late summer 1992, with less intensive sampling in midsummer. In addition, multiple samples were collected during two high- flow periods at the Maple Creek site--one early and the other late in the growing season. Water-samples analyses included determination of pesticides, nutrients, major ions, suspended sediment, and measurements of physical properties. Equipment and protocols for the water-quality sampling procedures were evaluated. Operation of the prototype stream- monitoring sites included development and comparison of onsite and laboratory sample-processing proce- dures. Onsite processing was labor intensive but allowed for immediate preservation of all sampled constituents. Laboratory processing required less field labor and decreased the risk of contamination, but allowed for no immediate preservation of the samples.

  19. New Hampshire Quality Rating System: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of New Hampshire's Quality Rating System prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4)…

  20. Assessment of the Quality Management Models in Higher Education

    ERIC Educational Resources Information Center

    Basar, Gulsun; Altinay, Zehra; Dagli, Gokmen; Altinay, Fahriye

    2016-01-01

    This study involves the assessment of the quality management models in Higher Education by explaining the importance of quality in higher education and by examining the higher education quality assurance system practices in other countries. The qualitative study was carried out with the members of the Higher Education Planning, Evaluation,…

  1. The Emergence of Quality Assessment in Brazilian Basic Education

    ERIC Educational Resources Information Center

    Kauko, Jaakko; Centeno, Vera Gorodski; Candido, Helena; Shiroma, Eneida; Klutas, Anni

    2016-01-01

    The focus in this article is on Brazilian education policy, specifically quality assurance and evaluation. The starting point is that quality, measured by means of large-scale assessments, is one of the key discursive justifications for educational change. The article addresses the questions of how quality evaluation became a significant feature…

  2. Assessment and the Quality of Educational Programmes: What Constitutes Evidence?

    ERIC Educational Resources Information Center

    Shay, Sueellen; Jawitz, Jeff

    2005-01-01

    In a climate of growing accountability for Higher Education, there is an increased demand on assessment to play an evaluative role. National, professional and institutional quality assurance systems expect that the assessment of student performance can be used to evaluate the quality of teachers, learners, programmes and even institutions for the…

  3. Evaluation of a procedure to assess the adverse effects of illicit drugs.

    PubMed

    van Amsterdam, J G C; Best, W; Opperhuizen, A; de Wolff, F A

    2004-02-01

    The assessment procedure of new synthetic illicit drugs that are not documented in the UN treaty on psychotropic drugs was evaluated using a modified Electre model. Drugs were evaluated by an expert panel via the open Delphi approach, where the written score was discussed on 16 items, covering medical, health, legal, and criminalistic issues of the drugs. After this face-to-face discussion the drugs were scored again. Taking the assessment of ketamine as an example, it appeared that each expert used its own scale to score, and that policymakers do not score deviant from experts trained in the medical-biological field. Of the five drugs evaluated by the panel, p-methoxy-metamphetamine (PMMA), gamma-hydroxybutyric acid (GHB), and 4-methylthio-amphetamine (MTA) were assessed as more adverse than ketamine and psilocine and psilocybine-containing mushrooms. Whereas some experts slightly adjusted during the assessment procedure their opinion on ketamine and PMMA, the opinion on mushrooms was not affected by the discussion held between the two scoring rounds. All experts rank the five drugs in a similar way on the adverse effect scale i.e., concordance scale of the Electre model, indicating unanimity in the expert panel with respect to the risk classification of these abused drugs.

  4. Ohio Step Up to Quality: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Ohio's Step Up to Quality prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for Family…

  5. Parasitology: United Kingdom National Quality Assessment Scheme.

    PubMed Central

    Hawthorne, M.; Chiodini, P. L.; Snell, J. J.; Moody, A. H.; Ramsay, A.

    1992-01-01

    AIMS: To assess the results from parasitology laboratories taking part in a quality assessment scheme between 1986 and 1991; and to compare performance with repeat specimens. METHODS: Quality assessment of blood parasitology, including tissue parasites (n = 444; 358 UK, 86 overseas), and faecal parasitology, including extra-intestinal parasites (n = 205; 141 UK, 64 overseas), was performed. RESULTS: Overall, the standard of performance was poor. A questionnaire distributed to participants showed that a wide range of methods was used, some of which were considered inadequate to achieve reliable results. Teaching material was distributed to participants from time to time in an attempt to improve standards. CONCLUSIONS: Since the closure of the IMLS fellowship course in 1972, fewer opportunities for specialised training in parasitology are available: more training is needed. Poor performance in the detection of malarial parasites is mainly attributable to incorrect speciation, misidentification, and lack of equipment such as an eyepiece graticule. PMID:1452791

  6. Assessment of Competence in EVAR Procedures: A Novel Rating Scale Developed by the Delphi Technique.

    PubMed

    Strøm, M; Lönn, L; Bech, B; Schroeder, T V; Konge, L

    2017-07-01

    To develop a procedure specific global rating scale for assessment of operator competence in endovascular aortic repair (EVAR). A Delphi approach was used to achieve expert consensus. A panel of 32 international experts (median 300 EVAR procedures, range 200-3000) from vascular surgery (n = 21) and radiology (n = 11) was established. The first Delphi round was based on a review of endovascular skills assessment papers, stent graft instructions for use, and structured interviews. It led to a primary pool of 83 items that were formulated as global rating scale items with tentative anchors. Iterative Delphi rounds were executed. The panellists rated the importance of each item on a 5 point Likert scale. Consensus was defined as 80% of the panel rating an item 4 or 5 in the primary round and 90% in subsequent rounds. Consensus on the final assessment tool was defined as Cronbach's alpha > .8 after a minimum of three rounds. Thirty-two of 35 invited experts participated. Three rounds of surveys were completed with a completion rate of 100% in the first two rounds and 91% in round three. The 83 primary assessment items were supplemented with five items suggested by the panel and reduced to seven pivotal assessment items that reached consensus, Cronbach's alpha = 0.82. The seven item rating scale covers key elements of competence in EVAR stent placement and deployment. Each item has well defined grades with explicit anchors at unacceptable, acceptable, and superior performance on a 5 point Likert scale. The Delphi methodology allowed for international consensus on a new procedure specific global rating scale for assessment of competence in EVAR. The resulting scale, EndoVascular Aortic Repair Assessment of Technical Expertise (EVARATE), represents key elements in the procedure. EVARATE constitutes an assessment tool for providing structured feedback to endovascular operators in training. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier

  7. Algorithm for automatic forced spirometry quality assessment: technological developments.

    PubMed

    Melia, Umberto; Burgos, Felip; Vallverdú, Montserrat; Velickovski, Filip; Lluch-Ariet, Magí; Roca, Josep; Caminal, Pere

    2014-01-01

    We hypothesized that the implementation of automatic real-time assessment of quality of forced spirometry (FS) may significantly enhance the potential for extensive deployment of a FS program in the community. Recent studies have demonstrated that the application of quality criteria defined by the ATS/ERS (American Thoracic Society/European Respiratory Society) in commercially available equipment with automatic quality assessment can be markedly improved. To this end, an algorithm for assessing quality of FS automatically was reported. The current research describes the mathematical developments of the algorithm. An innovative analysis of the shape of the spirometric curve, adding 23 new metrics to the traditional 4 recommended by ATS/ERS, was done. The algorithm was created through a two-step iterative process including: (1) an initial version using the standard FS curves recommended by the ATS; and, (2) a refined version using curves from patients. In each of these steps the results were assessed against one expert's opinion. Finally, an independent set of FS curves from 291 patients was used for validation purposes. The novel mathematical approach to characterize the FS curves led to appropriate FS classification with high specificity (95%) and sensitivity (96%). The results constitute the basis for a successful transfer of FS testing to non-specialized professionals in the community.

  8. Outpatient commitment and procedural due process.

    PubMed

    Player, Candice Teri-Lowe

    2015-01-01

    A large empirical literature on Kendra's Law has assessed the impact of court ordered outpatient treatment on outcomes such as treatment adherence, psychiatric hospitalization, quality of life, and treatment costs. Missing from the empirical literature, however, is a better understanding of procedural due process under Kendra's Law. Procedural due process concerns the safeguards that must be in place when governments deprive persons of their liberties, for example--notice, the right to a hearing and the right to appeal. This article reports the findings from a qualitative study of procedural due process and assisted outpatient treatment hearings under Kendra's Law. Attorneys reported significant barriers to effective advocacy on behalf of their clients. Further, despite the shift from a medical model of civil commitment to a judicial model in the 1970s, by and large judges continue to accord great deference to clinical testimony. Copyright © 2015. Published by Elsevier Ltd.

  9. Field guide for collecting samples for analysis of volatile organic compounds in stream water for the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Shelton, Larry R.

    1997-01-01

    For many years, stream samples for analysis of volatile organic compounds have been collected without specific guidelines or a sampler designed to avoid analyte loss. In 1996, the U.S. Geological Survey's National Water-Quality Assessment Program began aggressively monitoring urban stream-water for volatile organic compounds. To assure representative samples and consistency in collection procedures, a specific sampler was designed to collect samples for analysis of volatile organic compounds in stream water. This sampler, and the collection procedures, were tested in the laboratory and in the field for compound loss, contamination, sample reproducibility, and functional capabilities. This report describes that sampler and its use, and outlines field procedures specifically designed to provide contaminant-free, reproducible volatile organic compound data from stream-water samples. These guidelines and the equipment described represent a significant change in U.S. Geological Survey instructions for collecting and processing stream-water samples for analysis of volatile organic compounds. They are intended to produce data that are both defensible and interpretable, particularly for concentrations below the microgram-per-liter level. The guidelines also contain detailed recommendations for quality-control samples.

  10. 1995 mask industry quality assessment

    NASA Astrophysics Data System (ADS)

    Bishop, Chris; Strott, Al

    1995-12-01

    The third annual mask industry assessment will again survey various industry companies for key performance measurements in the areas of quality and delivery. This year's assessment is enhanced to include the area of safety and further breakdown of the data into 5-inch vs. 6- inch. The data compiled includes shipments, customer return rate, customer return reason, performance to schedule, plate survival yield, and throughput time (TPT) from 1988 through Q2, 1995. Contributor identities remain protected by utilizing Arthur Andersen & Company to ensure participant confidentiality. Participation in the past included representation of over 75% of the total merchant and captive mask volume in the United States. This year's assessment is expected to result in expanded participation by again inviting all mask suppliers domestically to participate as well as an impact from inviting international suppliers to participate.

  11. Guidelines and standard procedures for studies of ground-water quality; selection and installation of wells, and supporting documentation

    USGS Publications Warehouse

    Lapham, W.W.; Wilde, F.D.; Koterba, M.T.

    1997-01-01

    This is the first of a two-part report to document guidelines and standard procedures of the U.S. Geological Survey for the acquisition of data in ground-water-quality studies. This report provides guidelines and procedures for the selection and installation of wells for water-quality studies/*, and the required or recommended supporting documentation of these activities. Topics include (1) documentation needed for well files, field folders, and electronic files; (2) criteria and information needed for the selection of water-supply and observation wells, including site inventory and data collection during field reconnaissance; and (3) criteria and preparation for installation of monitoring wells, including the effects of equipment and materials on the chemistry of ground-water samples, a summary of drilling and coring methods, and information concerning well completion, development, and disposition.

  12. Assessing the Item Response Theory with Covariate (IRT-C) Procedure for Ascertaining Differential Item Functioning

    ERIC Educational Resources Information Center

    Tay, Louis; Vermunt, Jeroen K.; Wang, Chun

    2013-01-01

    We evaluate the item response theory with covariates (IRT-C) procedure for assessing differential item functioning (DIF) without preknowledge of anchor items (Tay, Newman, & Vermunt, 2011). This procedure begins with a fully constrained baseline model, and candidate items are tested for uniform and/or nonuniform DIF using the Wald statistic.…

  13. How do we know? An assessment of integrated community case management data quality in four districts of Malawi.

    PubMed

    Yourkavitch, Jennifer; Zalisk, Kirsten; Prosnitz, Debra; Luhanga, Misheck; Nsona, Humphreys

    2016-11-01

    The World Health Organization contracted annual data quality assessments of Rapid Access Expansion (RAcE) projects to review integrated community case management (iCCM) data quality and the monitoring and evaluation (M&E) system for iCCM, and to suggest ways to improve data quality. The first RAcE data quality assessment was conducted in Malawi in January 2014 and we present findings pertaining to data from the health management information system at the community, facility and other sub-national levels because RAcE grantees rely on that for most of their monitoring data. We randomly selected 10 health facilities (10% of eligible facilities) from the four RAcE project districts, and collected quantitative data with an adapted and comprehensive tool that included an assessment of Malawi's M&E system for iCCM data and a data verification exercise that traced selected indicators through the reporting system. We rated the iCCM M&E system across five function areas based on interviews and observations, and calculated verification ratios for each data reporting level. We also conducted key informant interviews with Health Surveillance Assistants and facility, district and central Ministry of Health staff. Scores show a high-functioning M&E system for iCCM with some deficiencies in data management processes. The system lacks quality controls, including data entry verification, a protocol for addressing errors, and written procedures for data collection, entry, analysis and management. Data availability was generally high except for supervision data. The data verification process identified gaps in completeness and consistency, particularly in Health Surveillance Assistants' record keeping. Staff at all levels would like more training in data management. This data quality assessment illuminates where an otherwise strong M&E system for iCCM fails to ensure some aspects of data quality. Prioritizing data management with documented protocols, additional training and

  14. A Classical Conditioning Procedure for the Hearing Assessment of Multiply Handicapped Persons.

    ERIC Educational Resources Information Center

    Lancioni, Giulio E.; And Others

    1989-01-01

    Hearing assessments of multiply handicapped children/adolescents were conducted using classical conditioning (with an air puff as unconditioned stimulus) and operant conditioning (with a modified visual reinforcement audiometry procedure or edible reinforcement). Findings indicate that classical conditioning was successful with 21 of the 23…

  15. Quality Assessment of Medical Apps that Target Medication-Related Problems.

    PubMed

    Loy, John Shiguang; Ali, Eskinder Eshetu; Yap, Kevin Yi-Lwern

    2016-10-01

    The advent of smartphones has enabled a plethora of medical apps for disease management. As of 2012, there are 40,000 health care-related mobile apps available in the market. Since most of these medical apps do not go through any stringent quality assessment, there is a risk of consumers being misinformed or misled by unreliable information. In this regard, apps that target medication-related problems (MRPs) are not an exception. There is little information on what constitutes quality in apps that target MRPs and how good the existing apps are. To develop a quality assessment tool for evaluating apps that target MRPs and assess the quality of such apps available in the major mobile app stores (iTunes and Google Play). The top 100 free and paid apps in the medical categories of iTunes and Google Play stores (total of 400 apps) were screened for inclusion in the final analysis. English language apps that targeted MRPs were downloaded on test devices to evaluate their quality. Apps intended for clinicians, patients, or both were eligible for evaluation. The quality assessment tool consisted of 4 sections (appropriateness, reliability, usability, privacy), which determined the overall quality of the apps. Apps that fulfilled the inclusion criteria were classified based on the presence of any 1 or more of the 5 features considered important for apps targeting MRPs (monitoring, interaction checker, dose calculator, medication information, medication record). Descriptive statistics and Mann-Whitney tests were used for analysis. Final analysis was based on 59 apps that fulfilled the study inclusion criteria. Apps with interaction checker (66.9%) and monitoring features (54.8%) had the highest and lowest overall qualities. Paid apps generally scored higher for usability than free apps (P = 0.006) but lower for privacy (P = 0.003). Half of the interaction checker apps were unable to detect interactions with herbal medications. Blood pressure and heart rate monitoring apps

  16. Tools used to assess medical students competence in procedural skills at the end of a primary medical degree: a systematic review.

    PubMed

    Morris, Marie C; Gallagher, Tom K; Ridgway, Paul F

    2012-01-01

    The objective was to systematically review the literature to identify and grade tools used for the end point assessment of procedural skills (e.g., phlebotomy, IV cannulation, suturing) competence in medical students prior to certification. The authors searched eight bibliographic databases electronically - ERIC, Medline, CINAHL, EMBASE, Psychinfo, PsychLIT, EBM Reviews and the Cochrane databases. Two reviewers independently reviewed the literature to identify procedural assessment tools used specifically for assessing medical students within the PRISMA framework, the inclusion/exclusion criteria and search period. Papers on OSATS and DOPS were excluded as they focused on post-registration assessment and clinical rather than simulated competence. Of 659 abstracted articles 56 identified procedural assessment tools. Only 11 specifically assessed medical students. The final 11 studies consisted of 1 randomised controlled trial, 4 comparative and 6 descriptive studies yielding 12 heterogeneous procedural assessment tools for analysis. Seven tools addressed four discrete pre-certification skills, basic suture (3), airway management (2), nasogastric tube insertion (1) and intravenous cannulation (1). One tool used a generic assessment of procedural skills. Two tools focused on postgraduate laparoscopic skills and one on osteopathic students and thus were not included in this review. The levels of evidence are low with regard to reliability - κ = 0.65-0.71 and minimum validity is achieved - face and content. In conclusion, there are no tools designed specifically to assess competence of procedural skills in a final certification examination. There is a need to develop standardised tools with proven reliability and validity for assessment of procedural skills competence at the end of medical training. Medicine graduates must have comparable levels of procedural skills acquisition entering the clinical workforce irrespective of the country of training.

  17. Assuring Quality in Collaborative Provision.

    ERIC Educational Resources Information Center

    Bocock, Jean; Edwards, Judith

    1998-01-01

    This bulletin is intended to help British further education colleges clarify their rationale for entering into collaborative programs, assess prospective partners, define and implement good practice at all stages of provision, and establish rigorous quality assurance procedures. Following an introduction, Further Education Funding Council…

  18. Tri-Service Procedural Guidelines for Ecological Risk Assessments. Volume 1.

    DTIC Science & Technology

    1996-05-01

    appearance of product changes pH and a pH sensitive dye is present in the medium), by change in turbidity, or by the production of a precipitate or chemical...project has been the development of procedural guidelines for ecological risk assessment. The product of this effort will maximize the transfer of...constitute an official endorsement of any commercial products . This report may not be cited for the purpose of advertisement. This report has been

  19. Assessment of quality of life of parents of children with osteogenesis imperfecta.

    PubMed

    Szczepaniak-Kubat, Anna; Kurnatowska, Olga; Jakubowska-Pietkiewicz, Elzbieta; Chlebna-Sokół, Danuta

    2012-01-01

    The aim of the work was an objective assessment of the quality of life of parents of children with osteogenesis imperfecta (OI) and of its determinant factors. The survey answers of 25 parents were analyzed and contained demographic parameters, socioeconomic status information, quality of life of responses and type of support they have been receiving. In order to assess the effects of this children's disease on the quality of life of the parents, families were divided into two groups depending on the OI severity: group M--mild (type I and IV OI), group S--severe (type III OI). The objective of the work was carried out based on the WHOQOL-BREF quality of life questionnaire and measures of family status: education degree based on the International Standard Classification of Education (ISCED), a subjective assessment of the family's wealth (Perceived Family Wealth, PFW), and the family's financial resources (Family Affluence Scale, FAS). 56% of respondents assessed their global quality of life (Quality of Life, QL) as good, whereas 8% answered poor. Perception of general health status was similar. Life domains assessed in the WHOQOL-BREF questionnaire received the following mean values on a scale from 4 to 20 points: physical--12.2 +/- 1.2, psychological--15.04 +/- 2.2, environmental--13.32 +/- 2, social relationships--14.28 +/- 1.5. In the severe OI group, the environmental domain was assessed as worse than in the mild OI group and this assessment was statistically significant, despite the fact that the group of families with severe cases of OI received more support from the appropriate institutions. Indicators of socioeconomic status did not affect the respondents' assessment of their global quality of life. In the tested group of families, the child's disease did not affect either the global quality of life assessment or health of the respondents or their quality of life in terms of physical and mental status and social relationships. The parents of children with

  20. Assessing Public Metabolomics Metadata, Towards Improving Quality.

    PubMed

    Ferreira, João D; Inácio, Bruno; Salek, Reza M; Couto, Francisco M

    2017-12-13

    Public resources need to be appropriately annotated with metadata in order to make them discoverable, reproducible and traceable, further enabling them to be interoperable or integrated with other datasets. While data-sharing policies exist to promote the annotation process by data owners, these guidelines are still largely ignored. In this manuscript, we analyse automatic measures of metadata quality, and suggest their application as a mean to encourage data owners to increase the metadata quality of their resources and submissions, thereby contributing to higher quality data, improved data sharing, and the overall accountability of scientific publications. We analyse these metadata quality measures in the context of a real-world repository of metabolomics data (i.e. MetaboLights), including a manual validation of the measures, and an analysis of their evolution over time. Our findings suggest that the proposed measures can be used to mimic a manual assessment of metadata quality.